WorldWideScience

Sample records for high rise residential

  1. Indonesian residential high rise buildings: A life cycle energy assessment

    Energy Technology Data Exchange (ETDEWEB)

    Utama, Agya; Gheewala, Shabbir H. [The Joint Graduate School of Energy and Environment, King Mongkut' s University of Technology Thonburi, Bangkok (Thailand)

    2009-11-15

    This study evaluates the effect of building envelopes on the life cycle energy consumption of high rise residential buildings in Jakarta, Indonesia. For high rise residential buildings, the enclosures contribute 10-50% of the total building cost, 14-17% of the total material mass and 20-30% of the total heat gain. The direct as well as indirect influence of the envelope materials plays an important role in the life cycle energy consumption of buildings. The initial embodied energy of typical double wall and single wall envelopes for high residential buildings is 79.5 GJ and 76.3 GJ, respectively. Over an assumed life span of 40 years, double walls have better energy performance than single walls, 283 GJ versus 480 GJ, respectively. Material selection, which depends not only on embodied energy but also thermal properties, should, therefore, play a crucial role during the design of buildings. (author)

  2. A fire risk assessment model for residential high-rises with a single stairwell

    DEFF Research Database (Denmark)

    Hansen, N. D.; Steffensen, F.B.; Valkvist, M.B.

    2018-01-01

    As few or none prescriptive guidelines for fire risk assessment of residential high-rise buildings exist, it has been unclear which fire safety design features constitute an acceptable (adequate) safety level. In order to fill this gap a simplified risk-based decision-support tool, the Fire Risk...... Model (FRM), was developed. The FRM evaluates both the risk level to the occupants and the property risk level as a function of the building characteristics, height and fire safety features for single stairwell residential high-rise buildings. The acceptability of a high-rise design is then defined...

  3. The Airborne Transmission of Infection Between Flats in High-rise Residential Buildings

    DEFF Research Database (Denmark)

    Gao, N. P.; Niu, J. L.; Perino, M.

    2009-01-01

    Several case clusters occurred in high-rise residential buildings in Hong Kong in the 2003 SARS (the severe acute respiratory syndrome) epidemic, which motivated a series of engineering investigations into the possible airborne transport routes. It is suspected that, driven by buoyancy force...

  4. An Analysis on Optimization of Living and Fire Water Supply Systems of Small High-Rise Residential Blocks

    Science.gov (United States)

    Yuan, Min

    2017-11-01

    With the rapid growth of our population, the demand for housing quality of urban residents has been gradually raised. Due to the shortage of traditional multi-storey residential and high-rise residential, it is difficult to achieve a balance between quality and quantity of housing. As a result, a new type of residential building, small high-rise residential building, came into being. The so-called small high-rise residential generally refers to buildings of 7 to 11 layers, including unit buildings and tower buildings. In view of the problems existing in the water supply system of the small high-rise residential blocks, this paper presents a new system, namely a combined system of living and fire water supply. This system can be, according to the available pressure of municipal pipeline network, divided into three types, and has been optimized in order to fully utilize the municipal pipeline network pressure

  5. Suite Ventilation Characteristics of Current Canadian Mid-andHigh-Rise Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Wray, Craig P.

    2000-01-01

    This paper characterizes ventilation in residential suiteslocated in ll buildings were between six and thirty-two stories tall andwere built between 1990 and 1995. The key findings from field performancetests of these buildings were: 1. Corridor supply airflows usually didnot meet design flows.2. Makeup air paths for suite exhaust were notproperly designed.3. Suite access door leakage was highly variable andusually did not meet smoke control requirements.4. Airflow from thecorridor through the suite access door leakage appeared to be the primaryventilation air supply for suites.5. Suites were usually well-ventilated,but some were marginally- or under-ventilated.6. Poor pressure controloften allowed transfer air from one suite to another. Inter-suitetransfer air fractions ranged from 0 to 45 percent, with an average of 19percent. In summary, this work showed suite ventilation can be highlyinfluenced by corridor supply flows, by the treatment of corridor accessdoors, and by transfer airflows. As a result, suite ventilation at anygiven time in current mid- and high-rise residential buildings is verydifficult to predict. To ensure suite ventilation performs as intendedunder all operating conditions, the building industry needs to addressthe identified problems through improved ventilation design, operation,and maintenance practices.

  6. High rise buildings

    Energy Technology Data Exchange (ETDEWEB)

    Horn, M.

    1980-06-01

    The feasibility of developing new energy conservation standards for high rise residential-type buildings including hotels, motels, apartment houses, and lodging houses is discussed. Differences between the high and low rise residential building energy regulations are summarized. The data collection method and results are presented. (MCW)

  7. Single-point reactive power control method on voltage rise mitigation in residential networks with high PV penetration

    DEFF Research Database (Denmark)

    Hasheminamin, Maryam; Agelidis, Vassilios; Ahmadi, Abdollah

    2018-01-01

    Voltage rise (VR) due to reverse power flow is an important obstacle for high integration of Photovoltaic (PV) into residential networks. This paper introduces and elaborates a novel methodology of an index-based single-point-reactive power-control (SPRPC) methodology to mitigate voltage rise by ...... system with high r/x ratio. Efficacy, effectiveness and cost study of SPRPC is compared to droop control to evaluate its advantages....... by absorbing adequate reactive power from one selected point. The proposed index utilizes short circuit analysis to select the best point to apply this Volt/Var control method. SPRPC is supported technically and financially by distribution network operator that makes it cost effective, simple and efficient...

  8. APPLYING THE VERNACULAR MODEL TO HIGH-RISE RESIDENTIAL DEVELOPMENT IN THE MIDDLE EAST AND NORTH AFRICA

    Directory of Open Access Journals (Sweden)

    Amer Al-Jokhadar

    2017-07-01

    Full Text Available In the age of globalisation and continuous urbanisation, architects have a greater responsibility to design residential buildings with comfortable and sustainable environments. However, sustainable solutions should not concern themselves only with utilising technology, but also with creating synergies amongst a community’s social, cultural, historical, and environmental aspects. This research focuses on the implications of this wider definition of sustainability within the hot-arid climates of the Middle East and North Africa. Most of the current high-rise residential buildings in these regions do not promote social cohesion as they have been constructed without consideration for local identity and lifestyle. In contrast, vernacular courtyard dwellings and neighbourhoods offer good examples of socially cohesive and healthy environments. Yet, vernacular houses might not be compatible with pressures of modern construction. The question then becomes how to maintain the relationship between the spatial, social and environmental aspects while employing the latest technologies and materials. This paper presents the different qualities of vernacular houses and neighbourhoods in the different regions of the Middle East and North Africa. Social and spatial relationships of different cases are assessed, through a typological analysis approach using a developed syntactic-geometric model, to trace the lifestyle and the cultural values of the society. The aim is a parametric exploration of appropriate sustainable solutions that facilitate the synergy of socio-climatic requirements, the well-being qualities of the residents, and the specifics of culture, time and people while designing sustainable high-rise developments.

  9. Research on modeling cogeneration-based residential energy systems in rowhouse and high-rise buildings. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Rodberg, L.; Jacobstein, N.; McNamara, M.; Shapiro, K.; Commoner, B.

    1984-09-01

    A Residential Cogeneration Analysis program has been developed to describe the behavior of cogeneration-based energy systems in urban high-rise buildings and rowhouses. The Program identifies three cogeneration systems which might be installed in the user's building, operating in stand-alone, segregated-load, and utility back-up modes. Information is provided on energy consumption before and after the installation of these cogeneration systems, and a series of economic analyses is performed. Using the program, an analysis was performed of the effect of installing a cogeneration system in a 12-story, 48-unit apartment building in New York City. The most cost-effective mode of operation is the utility back-up mode, in which the cogenerator meets the base electrical and domestic hot water load of the building, with the utility grid providing additional electricity and the existing boiler meeting additional heating loads. In this mode of operation, the simple payback period is approximately two years. A conventional power plant converts only about one-third of the energy available from its fuel into electricity; the remaining two-thirds is not used, but is simply ejected into the atmosphere or nearby rivers. A cogenerator captures this heat for useful purposes, such as providing space heat or domestic hot water. As a result, a cogenerator can operate at an overall efficiency of 60% or better, compared with less than 33% for conventionally generated power. In recent years small cogeneration units suitable for use in residential buildings have become available. Such units can substantially reduce energy costs for the residents of high-rise apartment buildings or a set of adjoining rowhouses. CBNS has assembled data on all currently available cogeneration systems of capacity below 200 kilowatts, along with the heat recovery and electrical control equipment that would be used with these systems. 14 refs.

  10. The Airborne Transmission of Infection Between Flats in High-rise Residential Buildings

    DEFF Research Database (Denmark)

    Gao, N.P.; Niu, J. L.; Perino, M.

    2008-01-01

    Airborne transmission of infectious respiratory diseases in indoor environments has drawn our attention for decades, and this issue is revitalized with the outbreak of severe acute respiratory syndrome (SARS). One of the concerns is that there may be multiple transmission routes across households....... High-speed winds can restrain the convective transfer of heat and mass between flats, functioning like an air curtain. Despite the complexities of the air flow involved, it is clear that this transmission route should be taken into account in infection control....... of magnitude, but the risk of infection calculated by the Wells-Riley equation is only around one order of magnitude lower. It is found that, with single-side open-window conditions, wind blowing perpendicularly to the building may either reinforce or suppress the upward transport, depending on the wind speed......Airborne transmission of infectious respiratory diseases in indoor environments has drawn our attention for decades, and this issue is revitalized with the outbreak of severe acute respiratory syndrome (SARS). One of the concerns is that there may be multiple transmission routes across households...

  11. Facilities Management Service Delivery in Public and Private High Rise Residential Buildings in Nigeria: A case study of Eko Court Complex and Niger Towers

    Directory of Open Access Journals (Sweden)

    Olanrele O. O.

    2014-01-01

    Full Text Available This study assessed and compared the delivery of Facilities Management (FM services in public and private high rise residential buildings in Lagos, Nigeria. While some facilities or services may not be available in some public estates, the efficiency of the available ones is inadequate in comparison with the adequacy and efficiency of services provided in private estates. The objectives set for the study include identification of services that are provided in the case studies, service delivery method, and an assessment of the residents’ satisfaction of the services. This study adopted questionnaire survey for collection of data. 127 questionnaires were distributed to the residents of the case studies and 93 were returned. Three of which were discarded for incompleteness, thus 90 were analysed. The study found that most but not all of the facilities services expected in high rise buildings are available in the case studies and the services are outsourced under a standard Service Level Agreement. The service delivery in private high rise residential building is better than the public residential high rise buildings as revealed by the study. The study recommends improved standardization of services, customized services and meeting customer’s expectation for improved service delivery.

  12. Indoor air quality in green buildings: A case-study in a residential high-rise building in the northeastern United States.

    Science.gov (United States)

    Xiong, Youyou; Krogmann, Uta; Mainelis, Gediminas; Rodenburg, Lisa A; Andrews, Clinton J

    2015-01-01

    Improved indoor air quality (IAQ) is one of the critical components of green building design. Green building tax credit (e.g., New York State Green Building Tax Credit (GBTC)) and certification programs (e.g., Leadership in Energy & Environmental Design (LEED)) require indoor air quality measures and compliance with allowable maximum concentrations of common indoor air pollutants. It is not yet entirely clear whether compliance with these programs results in improved IAQ and ultimately human health. As a case in point, annual indoor air quality measurements were conducted in a residential green high-rise building for five consecutive years by an industrial hygiene contractor to comply with the building's GBTC requirements. The implementation of green design measures resulted in better IAQ compared to data in references of conventional homes for some parameters, but could not be confirmed for others. Relative humidity and carbon dioxide were satisfactory according to existing standards. Formaldehyde levels during four out of five years were below the most recent proposed exposure limits found in the literature. To some degree, particulate matter (PM) levels were lower than that in studies from conventional residential buildings. Concentrations of Volatile Organic Compounds (VOCs) with known permissible exposure limits were below levels known to cause chronic health effects, but their concentrations were inconclusive regarding cancer health effects due to relatively high detection limits. Although measured indoor air parameters met all IAQ maximum allowable concentrations in GBTC and applicable LEED requirements at the time of sampling, we argue that these measurements were not sufficient to assess IAQ comprehensively because more sensitive sampling/analytical methods for PM and VOCs are needed; in addition, there is a need for a formal process to ensure rigor and adequacy of sampling and analysis methods. Also, we suggest that a comprehensive IAQ assessment should

  13. The Influence of Place Making’s Attributes on the Resident’s Usage and Satisfaction in High-Rise Residential Community: A Case Study

    OpenAIRE

    Aflaki Ardalan; Mahyuddin Norhayati; Samzadeh Mozhgan; Mirnezhad Mahsan

    2016-01-01

    The vitality and viability of open spaces in urban neighborhoods, particularly in high-density residential areas with limited buildable land, have become extremely complex phenomenon. Researchers and designers are seeking the standard of designed environment to successfully meet the human needs and desires. In order to reach this goal, limited studies have been implemented to bridge the gap between research and design and consequently improve the physical and social qualities of open spaces. ...

  14. The Influence of Place Making’s Attributes on the Resident’s Usage and Satisfaction in High-Rise Residential Community: A Case Study

    Directory of Open Access Journals (Sweden)

    Aflaki Ardalan

    2016-01-01

    Full Text Available The vitality and viability of open spaces in urban neighborhoods, particularly in high-density residential areas with limited buildable land, have become extremely complex phenomenon. Researchers and designers are seeking the standard of designed environment to successfully meet the human needs and desires. In order to reach this goal, limited studies have been implemented to bridge the gap between research and design and consequently improve the physical and social qualities of open spaces. This paper examines the two specific features of open space accessibility, social interactions - which contribute significantly to both the vitality and viability with a view to provide an understanding of the relative importance of these elements from users’ perceptions and satisfaction. The methods involve quantitative research with questionnaire-based survey, and case study to evaluate residents’ perceptions. The research scope is a high-density residential condominium in Kuala Lumpur where the rapid transformation of urban elements in city center has negative impacts on basic qualities of open spaces. The result is a framework for understanding the relative priority of the different elements (variables for users which vary depending on the location of the residential block they live in; in particular its proximity to the open space. The study concludes with recommendations for how the most valuable elements can be better harnessed in order to promote the satisfaction with open spaces.

  15. Disposal of Kitchen Waste from High Rise Apartment

    Science.gov (United States)

    Ori, Kirki; Bharti, Ajay; Kumar, Sunil

    2017-09-01

    The high rise building has numbers of floor and rooms having variety of users or tenants for residential purposes. The huge quantities of heterogenous mixtures of domestic food waste are generated from every floor of the high rise residential buildings. Disposal of wet and biodegradable domestic kitchen waste from high rise buildings are more expensive in regards of collection and vertical transportation. This work is intended to address the technique to dispose of the wet organic food waste from the high rise buildings or multistory building at generation point with the advantage of gravity and vermicomposting technique. This innovative effort for collection and disposal of wet organic solid waste from high rise apartment is more economical and hygienic in comparison with present system of disposal.

  16. Disposal of Kitchen Waste from High Rise Apartment

    Science.gov (United States)

    Ori, Kirki; Bharti, Ajay; Kumar, Sunil

    2017-07-01

    The high rise building has numbers of floor and rooms having variety of users or tenants for residential purposes. The huge quantities of heterogenous mixtures of domestic food waste are generated from every floor of the high rise residential buildings. Disposal of wet and biodegradable domestic kitchen waste from high rise buildings are more expensive in regards of collection and vertical transportation. This work is intended to address the technique to dispose of the wet organic food waste from the high rise buildings or multistory building at generation point with the advantage of gravity and vermicomposting technique. This innovative effort for collection and disposal of wet organic solid waste from high rise apartment is more economical and hygienic in comparison with present system of disposal.

  17. Optimal and heuristic algorithms of planning of low-rise residential buildings

    Science.gov (United States)

    Kartak, V. M.; Marchenko, A. A.; Petunin, A. A.; Sesekin, A. N.; Fabarisova, A. I.

    2017-10-01

    The problem of the optimal layout of low-rise residential building is considered. Each apartment must be no less than the corresponding apartment from the proposed list. Also all requests must be made and excess of the total square over of the total square of apartment from the list must be minimized. The difference in the squares formed due to with the discreteness of distances between bearing walls and a number of other technological limitations. It shown, that this problem is NP-hard. The authors built a linear-integer model and conducted her qualitative analysis. As well, authors developed a heuristic algorithm for the solution tasks of a high dimension. The computational experiment was conducted which confirming the efficiency of the proposed approach. Practical recommendations on the use the proposed algorithms are given.

  18. Super high-rise buildings

    Energy Technology Data Exchange (ETDEWEB)

    Maryon, J.C.

    1987-04-14

    This patent describes a super high-rise building for human occupation having at least 100 vertically spaced, human-occupiable stories comprising: a foundation; and a hollow vertical prism of reinforced concrete, mounted on the foundation and being at least 100 stories high, for transmitting to the foundation substantially all loads above at least the 75th floor of the building in a manner such that automatic lateral rigidity, stability, and strength are attained. The sides of the prism have apertures for such purposes as allowing human movement between the inside end and outside of the prism. The portion of substantially any horizontal circumference of the prism which is occupied by the apertures is less than about 25% of the horizontal circumference.

  19. Structural Risk Assessment and Mitigation for Low- to Mid-Rise Residential Buildings in China

    Directory of Open Access Journals (Sweden)

    Kasim A. Korkmaz

    2017-07-01

    Full Text Available China has experienced major earthquakes recently. The 2014 Ludian earthquake struck Ludian County, Yunnan, (Mw = 6.1 on 3 August, 2014. On April 20th 2013, Ya’an earthquake (Mw = 6.9, on April 14th 2010, Qinghai earthquake (Mw = 7.1, on July 9th 2009, Yunnan earthquake (Mw = 6.0, and on May 12th 2008, Sichuan earthquake (Mw = 7.9 struck China. Among these disasters, the most devastating, the Sichuan earthquake, resulted in the collapse of 5 million buildings and damage to more than 21 million. Human loss was also high with over 60,000 people dead, 360,000 injured, and more than 14 million people displaced. South-west China lies in an area that is prone to earthquakes. In 1970, a magnitude 7.7 earthquake in Yunnan with 15,000 lost. This study presents a detailed risk assessment for a structural risk assessment and mitigation for low- to mid-rise residential buildings for China. The risk assessment, through seismic hazard assessment approaches, evaluates the impact of the disasters for integrated structural health monitoring. Among the results of the investigation, relations and links between safety and risk are defined.

  20. Strategy Guideline: High Performance Residential Lighting

    Energy Technology Data Exchange (ETDEWEB)

    Holton, J.

    2012-02-01

    The Strategy Guideline: High Performance Residential Lighting has been developed to provide a tool for the understanding and application of high performance lighting in the home. The high performance lighting strategies featured in this guide are drawn from recent advances in commercial lighting for application to typical spaces found in residential buildings. This guide offers strategies to greatly reduce lighting energy use through the application of high quality fluorescent and light emitting diode (LED) technologies. It is important to note that these strategies not only save energy in the home but also serve to satisfy the homeowner's expectations for high quality lighting.

  1. 76 FR 49279 - Energy Efficiency Design Standards for New Federal Commercial and Multi-Family High-Rise...

    Science.gov (United States)

    2011-08-10

    ... 1904-AC41 Energy Efficiency Design Standards for New Federal Commercial and Multi-Family High-Rise Residential Buildings and New Federal Low-Rise Residential Buildings AGENCY: Office of Energy Efficiency and..., revised Federal building energy efficiency performance standards for new Federal buildings that require...

  2. Criteria Describing High-Rise Buildings

    OpenAIRE

    Ernestas Gaudutis

    2011-01-01

    Although the evolution of high rise buildings according to different literature sources counts the 2nd century, however, until now, no universally accepted criterion to characterize them has been established. Considering standards used in different countries of the world and various sources of literature, this article tries to sign the existing situation and offer a criterion to mark high rise buildings. The analysis of the reasons of the notion describing high rise buildings is carried out a...

  3. Criteria Describing High-Rise Buildings

    Directory of Open Access Journals (Sweden)

    Ernestas Gaudutis

    2011-04-01

    Full Text Available Although the evolution of high rise buildings according to different literature sources counts the 2nd century, however, until now, no universally accepted criterion to characterize them has been established. Considering standards used in different countries of the world and various sources of literature, this article tries to sign the existing situation and offer a criterion to mark high rise buildings. The analysis of the reasons of the notion describing high rise buildings is carried out and its relations with high rise construction rudiments found in different cultures are characterized. Article in Lithuanian

  4. Empirical Operational Energy Analysis of Downtown High-Rise vs. Suburban Low-Rise Lifestyles: A Chicago Case Study

    Directory of Open Access Journals (Sweden)

    Peng Du

    2016-06-01

    Full Text Available It is widely accepted that the concentration of people living in high-density city centers offers greater operational energy efficiency and lower greenhouse gas emissions than lower-density expanded suburbs. The prevailing assumption is that lower-density suburbs are dominated by larger low-rise buildings that have higher building energy use requirements and greater per-person automobile travel requirements than high-density city centers dominated by medium- and high-rise buildings located in close proximity to a variety of public transit systems. However, very few studies to date have utilized empirical data at an individual household scale to evaluate differences in the operational energy (OE footprints for both building and transportation energy end-uses between high-rise urban and low-rise suburban households. Therefore, this work collects empirical data on building and transportation OE consumption by individuals and households living in two economically similar groups: existing high-rise residential buildings in downtown Chicago, IL, USA and existing low-rise residential buildings in suburban Oak Park, IL, USA. Data were collected from over 500 households via an online survey. We considered the following components of residential living: (1 building OE (BOE, which includes electricity and/or natural gas use for all building energy end-uses; and (2 transportation OE (TOE, which includes the OE for multiple modes of transportation (i.e., automobile, bus, subway, regional train, etc. based on average travel behavior in each location, as well as the OE for supporting transportation infrastructure. We estimate that downtown high-rise living in this sample of residences in Chicago, IL accounts for approximately 427 GJ of primary OE per household per year, on average, which was 14% lower than the average for suburban low-rise living in the Oak Park, IL homes (499 GJ per household per year. However, on a per-person basis, downtown high-rise living

  5. Life Satisfaction of Downtown High-Rise vs. Suburban Low-Rise Living: A Chicago Case Study

    Directory of Open Access Journals (Sweden)

    Peng Du

    2017-06-01

    Full Text Available There has been a long-standing debate about whether urban living is more or less sustainable than suburban living, and quality of life (QoL is one of several key measures of the social sustainability of residential living. However, to our knowledge, no study to date has examined life satisfaction among residents of downtown high-rise living compared to residents living in suburban low-rise housing. Further, very few studies have utilized building or neighborhood-scale data sets to evaluate residents’ life satisfaction, and even fewer have controlled for both individual and household-level variables such as gender, age, household size, annual income, and length of residence, to evaluate residents’ life satisfaction across different living scenarios. Therefore, the goal of this study was to investigate residents’ satisfaction with their place of residence as well as overall life in general via surveys of individuals living in existing high-rise residential buildings in downtown Chicago, IL, and in existing low-rise residential buildings in suburban Oak Park, IL. Over 1500 individuals were contacted directly, resulting in over 500 responses. The number of fully completed responses for this study was 177, including 94 from residents of four downtown high-rise buildings and 83 from residents in suburban low-rise homes. Residents living in downtown high-rise buildings had significantly higher life satisfaction scores than residents living in suburban low-rise homes when controlling for demographic differences; however, the differences were small, as housing type explained less than 5% of the observed variance in life satisfaction outcomes. The research also evaluated five life satisfaction domains including travel, accessibility, social interaction, safety, and overall residential environment (ORE. In all cases, residents of the downtown high-rises reported higher satisfaction levels, although the scores on all these five satisfaction domains

  6. Strategy Guideline. High Performance Residential Lighting

    Energy Technology Data Exchange (ETDEWEB)

    Holton, J. [IBACOS, Inc., Pittsburgh, PA (United States)

    2012-02-01

    This report has been developed to provide a tool for the understanding and application of high performance lighting in the home. The strategies featured in this guide are drawn from recent advances in commercial lighting for application to typical spaces found in residential buildings. This guide offers strategies to greatly reduce lighting energy use through the application of high quality fluorescent and light emitting diode (LED) technologies. It is important to note that these strategies not only save energy in the home but also serve to satisfy the homeowner’s expectations for high quality lighting.

  7. Indoor air quality in mechanically ventilated residential dwellings/low-rise buildings: A review of existing information

    DEFF Research Database (Denmark)

    Aganovic, Amar; Hamon, Mathieu; Kolarik, Jakub

    Mechanical ventilation has become a mandatory requirement in multiple European standards addressing indoor air quality (IAQ) and ventilation in residential dwellings (single family houses and low-rise apartment buildings). This article presents the state of the art study through a review of the e......Mechanical ventilation has become a mandatory requirement in multiple European standards addressing indoor air quality (IAQ) and ventilation in residential dwellings (single family houses and low-rise apartment buildings). This article presents the state of the art study through a review...... concentrations. The authors additionally noted that the literature frequently reported the role of improper maintenance and use on deterioration of IAQ in residential dwellings. The summarized data and comments may provide useful information for future guidelines related to ventilation strategies designed...

  8. FIRE EVACUATION FROM HIGH-RISE BUILDINGS

    OpenAIRE

    Korol'chenko Aleksandr Yakovlevich; Dinh Cong Hung Dinh Cong Hung

    2012-01-01

    The authors argue that no collapse of structures is likely in the event of a fire emergency in multistoried buildings, rather, other fire-related factors may endanger the lives of people inside high-rise buildings exposed to the fire emergency, including open fire, sparks, high ambient temperature, smoke and toxic combustion products, reduced concentration of oxygen, and combined influence of various factors. In case of fire, the temperature inside buildings reaches 1100 °С. It exceeds th...

  9. Social Sustainability of High-Rise Buildings

    OpenAIRE

    Mohammad Javad Mahdavinejad; Ali Sadraie; Golrokh Sadraie

    2014-01-01

    Nowadays, High-rise building is proposed as a dominant form in world’s Major cities which its rapid growth has caused social and cultural concerns of the residents of these buildings. Social capital is remembered as a basis for economic development of any society. Its importance can be seen in the economic development of developing countries. Social capital is the invisible wealth of a country that encompasses institutions, relationships and norms that shape social interactions. In this paper...

  10. Efficient production of high-rise buildings

    OpenAIRE

    Hoseini, Hanif

    2007-01-01

    Production of one family houses has over time developed successfully in Sweden and producers have managed to reduce the production costs and industrialize the production process. The development has however not been that successful when it comes to high-rise buildings. There are many attempts made, but no one has really managed to create a product that can persuade the market. The systems used are not flexible and cannot cope very well with variations in the design. The aim of this work has b...

  11. FIRE EVACUATION FROM HIGH-RISE BUILDINGS

    Directory of Open Access Journals (Sweden)

    Korol'chenko Aleksandr Yakovlevich

    2012-10-01

    Full Text Available The authors argue that no collapse of structures is likely in the event of a fire emergency in multistoried buildings, rather, other fire-related factors may endanger the lives of people inside high-rise buildings exposed to the fire emergency, including open fire, sparks, high ambient temperature, smoke and toxic combustion products, reduced concentration of oxygen, and combined influence of various factors. In case of fire, the temperature inside buildings reaches 1100 °С. It exceeds the temperature of the ambient air acceptable for humans by far (70 °С. The experiments demonstrate that combustion products contain hundreds of toxic chemical compounds. The most hazardous of them include carbon oxide, carbon dioxide, chloride and cyanic hydrogen, aldehydes and acrolein. The author provides the pattern of their influence on the human body. The smoke consists of unburned particles of carbon and aerosols. The size of particles fluctuates within 0.05-50 MMK. Smoke produces a physiological and psychological impact on human beings. It has been proven that dangerous fire factors emerge within the first five to ten minutes of the emergency situation. Evacuation is the principal method of safety assurance. However, the velocity of propagation of smoke and heat is so high that even if the fire prevention system is in operation, people may be blocked both on the floors that are exposed to the fire and those that escape its propagation. New evacuation and rescue methods are recommended by the author. Various ways and methods of use of life-saving facilities are also provided. Safe evacuation is feasible from buildings where the number of stories does not exceed 10- 12. During evacuation, high density human streams are formed inside buildings, therefore, the period of stay in a burning building is increased. The calculations have proven that a two-minute delay of evacuation converts into a safe evacuation of only 13-15% of people. Low reliability of

  12. Life-Cycle Energy Implications of Downtown High-Rise vs. Suburban Low-Rise Living: An Overview and Quantitative Case Study for Chicago

    Directory of Open Access Journals (Sweden)

    Peng Du

    2015-09-01

    Full Text Available It is commonly accepted that the concentration of people in high-density urban city centers, which are typically dominated by medium- and high-rise buildings located close to public transit systems, offers greater overall energy efficiency and lower life-cycle greenhouse gas emissions than lower-density expanded suburbs, which are dominated by low-rise single-family buildings and larger per-person automobile travel requirements. However, few studies have combined quantitative analyses of the life-cycle energy use of both buildings and transportation in both urban and suburban areas, especially in American cities. This work uses a variety of data sources to provide a quantitative comparison of the life-cycle energy consumption associated with residential life (including buildings, transportation, and supporting infrastructure in prototypical downtown high-rises and suburban low-rises in and around Chicago, IL. We estimate that downtown high-rise living in Chicago, IL accounts for approximately 25% more life-cycle energy per person per year than suburban low-rise living, on average, contrary to some common beliefs (best estimates were ~141 and ~113 GJ/person/year, respectively. Building operational energy use was found to be the largest contributor of the total life-cycle energy in both the downtown high-rise and suburban low-rise cases, followed by vehicle operational energy.

  13. RISE

    DEFF Research Database (Denmark)

    Ortenzi, M.; Petrini, F.; Bontempi, F.

    2013-01-01

    This paper originates from a European research proposal entitled RISE (Resilient Infrastructures and Structures against Emergencies). In RISE the assessment of the resilience of an urban development is carried out within an effective theoretical framework in which the large scale urban built...... are considered both at a local level, by investi-gating the network elements (nodes and links) and at a global level, by considering the interactions between the elements and the response of the entire network. A basic application focusing on a specific analysis aspect (the local resilience of a critical...

  14. RISE

    DEFF Research Database (Denmark)

    Ortenzi, M.; Petrini, F.; Bontempi, F.

    2013-01-01

    infrastructure is perceived as a network, where nodes represent premises for the activities of the infrastructure and links represent the physical connections between them. The framework implies that the response to a critical event and the capability of recovering from the consequence of a disaster......This paper originates from a European research proposal entitled RISE (Resilient Infrastructures and Structures against Emergencies). In RISE the assessment of the resilience of an urban development is carried out within an effective theoretical framework in which the large scale urban built...... are considered both at a local level, by investi-gating the network elements (nodes and links) and at a global level, by considering the interactions between the elements and the response of the entire network. A basic application focusing on a specific analysis aspect (the local resilience of a critical...

  15. High Efficient Bidirectional Battery Converter for residential PV Systems

    DEFF Research Database (Denmark)

    Pham, Cam; Kerekes, Tamas; Teodorescu, Remus

    2012-01-01

    Photovoltaic (PV) installation is suited for the residential environment and the generation pattern follows the distribution of residential power consumption in daylight hours. In the cases of unbalance between generation and demand, the Smart PV with its battery storage can absorb or inject...... the power to balance it. High efficient bidirectional converter for the battery storage is required due high system cost and because the power is processed twice. A 1.5kW prototype is designed and built with CoolMOS and SiC diodes, >;95% efficiency has been obtained with 200 kHz hard switching....

  16. Impact of HVOTLs on Residential Property Rental Values in High ...

    African Journals Online (AJOL)

    High Voltage Overhead Transmission Lines (HVOTLs) otherwise refered to as power-lines have been debated to facilitate property value diminution. This current study investigates the impact of power-lines on the rents of residential properties in high brow Lagos. Questionnaires were distributed to registered Estate ...

  17. Progressive Collapse of High-Rise Buildings from Fire

    Directory of Open Access Journals (Sweden)

    Pershakov Valerii

    2016-01-01

    Full Text Available Considers ensuring the stability of structures of high-rise buildings against progressive collapse due to fire, proposed measures to ensure the stability of high-rise buildings due to progressive collapse. The analysis of large fires in high-rise buildings with progressive collapse and review of the literature on the issue of progressive collapse. The analysis of the Ukrainian normative documents on progressive collapse resistance.

  18. Microzonation of seismic risk in a low-rise Latin American city based on the macroseismic evaluation of the vulnerability of residential buildings: Colima city, México

    Directory of Open Access Journals (Sweden)

    V. M. Zobin

    2010-06-01

    Full Text Available A macroseismic methodology of seismic risk microzonation in a low-rise city based on the vulnerability of residential buildings is proposed and applied to Colima city, Mexico. The seismic risk microzonation for Colima consists of two elements: the mapping of residential blocks according to their vulnerability level and the calculation of an expert-opinion based damage probability matrix (DPM for a given level of earthquake intensity and a given type of residential block. A specified exposure time to the seismic risk for this zonation is equal to the interval between two destructive earthquakes. The damage probability matrices were calculated for three types of urban buildings and five types of residential blocks in Colima. It was shown that only 9% of 1409 residential blocks are able to resist to the Modify Mercalli (MM intensity VII and VIII earthquakes without significant damage. The proposed DPM-2007 is in good accordance with the experimental damage curves based on the macroseismic evaluation of 3332 residential buildings in Colima that was carried out after the 21 January 2003 intensity MM VII earthquake. This methodology and the calculated PDM-2007 curves may be applied also to seismic risk microzonation for many low-rise cities in Latin America, Asia, and Africa.

  19. Rethinking of Critical Regionalism in High-Rise Buildings

    Directory of Open Access Journals (Sweden)

    Nima Zahiri

    2016-12-01

    Full Text Available The character of height and density of newly high-rise cities, along with the force of globalization, have jeopardized the character of dwellings once entailing a regional flavor. The critical regionalism which serves as a resistant medium against placelessness and lack of identity in the International Style has focused more on mid-rise or low-rise solutions rather than providing direct high-rise resolutions. Additionally, high-rise endeavors are not compatible with critical regionalism theories. This has happened partly due to critical regionalism theories multi-facet character inherent in its dialectic structure. Thus, to remedy the inadvertency of texts in the discourse of architectural regionalism, the present study seeks rethinking of critical regionalism by focusing on the pathology of high-rise buildings in the issues pertaining to place and identity. Finally, the architectonic articulation to place-making and identity-giving is discussed.

  20. Evaluation of Parental Satisfaction of Children's Spaces Within High Rise Apartment Environments

    Directory of Open Access Journals (Sweden)

    Sharghi Ali

    2014-11-01

    Full Text Available In the design process of open spaces within residential apartments, little attention is paid to children and their attitude to the environment is often ignored. Children, especially those who live in high-rise apartments, were found to have less connection with nature. Children supposedly need to engage in physical activities within outdoor areas, but urban planners, with the approval of managers or parents, must adequately design the open space for children. This paper initially reviews different research in this area. It consequently attempts to evaluate parental satisfaction regarding children's connectivity to open spaces as a dependent variable, and their preferences and perception of safety as independent variables. The research method is based on a questionnaire survey addressed to 261 parents and adults, in two localities in Tehran, Iran. The result of this research shows that parental attitude to open space has an effect on children's outdoor activities. Moreover, parents with young children express lower satisfaction to open spaces than those adults without young children. Families with children need open spaces in residential high-rise apartments for their siblings’ physical activities, and the designers should consider such an important need.

  1. Infrastructure of Bulgarian High-Rise Estates: Realities and Hopes

    OpenAIRE

    Kalcheva, Elena; Taki, A. H.; Hadi, Yuri

    2017-01-01

    This chapter studies the quality and characteristics of the infrastructure in several high-rise estates in Sofia, Bulgaria and evaluates to which extend it serves the residents in the tall buildings. Most of the highrises in Sofia and their surroundings were built in the Soviet era so they represent a very old design concept and this is why it is no surprise that the quality of the public realm and the buildings is quite substandard. The spaces around the high-rises lack pub...

  2. Structural response of steel high rise buildings to fire

    DEFF Research Database (Denmark)

    Gentili, Filippo; Giuliani, Luisa; Bontempi, Franco

    2013-01-01

    Due to the significant vertical elevation and complexity of the structural system, high rise buildings may suffer from the effects of fire more than other structures. For this reason, in addition to evacuation strategies and active fire protection, a careful consideration of structural response...... to fire is also very important. In this context, it is of interest to investigate the characteristics of the structural system that could possibly reduce local damages or mitigate the progression of failures in case of fire. In this paper, a steel high rise building is taken as case study and the response...

  3. Envelope parameters, their effect on high-rise buildings

    Energy Technology Data Exchange (ETDEWEB)

    Sayers, M.J.

    1982-04-01

    Makeup of the exterior envelope of a high-rise building - walls, insulation, glass, mass - greatly affects both peak and total structure energy usages. The influence of a well-designed building envelope on energy conservation is considered and the effects of envelope parameters on high-rise building energy use and costs are addressed. A general guideline for the building design team is given. By knowing the ramifications of certain design decisions, a design team can effectively plan a useful and energy-efficient building.

  4. Rise and Shock: Optimal Defibrillator Placement in a High-rise Building.

    Science.gov (United States)

    Chan, Timothy C Y

    2017-01-01

    Out-of-hospital cardiac arrests (OHCA) in high-rise buildings experience lower survival and longer delays until paramedic arrival. Use of publicly accessible automated external defibrillators (AED) can improve survival, but "vertical" placement has not been studied. We aim to determine whether elevator-based or lobby-based AED placement results in shorter vertical distance travelled ("response distance") to OHCAs in a high-rise building. We developed a model of a single-elevator, n-floor high-rise building. We calculated and compared the average distance from AED to floor of arrest for the two AED locations. We modeled OHCA occurrences using floor-specific Poisson processes, the risk of OHCA on the ground floor (λ1) and the risk on any above-ground floor (λ). The elevator was modeled with an override function enabling direct travel to the target floor. The elevator location upon override was modeled as a discrete uniform random variable. Calculations used the laws of probability. Elevator-based AED placement had shorter average response distance if the number of floors (n) in the building exceeded three quarters of the ratio of ground-floor OHCA risk to above-ground floor risk (λ1/λ) plus one half (n ≥ 3λ1/4λ + 0.5). Otherwise, a lobby-based AED had shorter average response distance. If OHCA risk on each floor was equal, an elevator-based AED had shorter average response distance. Elevator-based AEDs travel less vertical distance to OHCAs in tall buildings or those with uniform vertical risk, while lobby-based AEDs travel less vertical distance in buildings with substantial lobby, underground, and nearby street-level traffic and OHCA risk.

  5. Energy reduction using biofiltration in a highly efficient residential home

    Science.gov (United States)

    Rodgers, Kevin L.

    The objective of this research was to design, demonstrate, and monitor the Biowall; a novel system for improving indoor air quality in a residential building, which has the potential to save energy compared to traditional air quality control. The Biowall was integrated into the heating, ventilation, and air-condition system of a high performance home and utilized plants as a passive filter system to remove volatile organic compounds from the interior space of the home. The testing environment in this study was a 984 square foot efficient residential home constructed for the U.S. Department of Energy Solar Decathlon 2011 competition. A number of sensors were installed in the home to monitor the operation of the wall including temperature, relative humidity, carbon dioxide, and total volatile organic compound (TVOC) sensors. The main outcomes of the project included the design and construction of a test platform for the current study and future research, energy results that showed as high as 160% energy savings over a 1 week test period and $170 per year in cost savings versus a traditional ventilation strategy, and lessons learned and suggestions for future research.

  6. Fiber Reinforced Concrete (FRC) for High Rise Construction: Case Studies

    Science.gov (United States)

    Gharehbaghi, Koorosh; Chenery, Rhea

    2017-12-01

    Due to its material element, Fiber Reinforced Concrete (FRC) could be stronger than traditional Concrete. This is due to FRC internal material compounds and elements. Furthermore, FRC can also significantly improve flexural strength when compared to traditional Concrete. This improvement in flexural strength can be varied depending on the actual fibers used. Although not new, FRC is gradually gaining popularity in the construction industry, in particular for high rise structures. This is due to its flexural strength, especially for high seismic zones, as it will provide a better solution then reinforced Concrete. The main aim of this paper is to investigate the structural importance of FRC for the high rise construction. Although there has been numerous studies and literature in justifying the FRC for general construction; this paper will consider its use specifically for high rise construction. Moreover, this paper will closely investigate eight case studies from Australian and United States as a part of the FRC validation for high rise construction. In doing so, this paper will examine their Structural Health Monitoring (SHM) to determine their overall structural performance.

  7. Managing Problems of Acceptability through High Rise-Fall Repetitions

    Science.gov (United States)

    Benjamin, Trevor; Walker, Traci

    2013-01-01

    This article examines one of the ways in which matters of truth, appropriateness, and acceptability are raised and managed within the course of everyday conversation. Using the methodology of conversation analysis, we show that by repeating what another participant has said and doing so with a high rise-fall intonation contour, a speaker claims…

  8. The support systems of unique high-rise buildings

    Directory of Open Access Journals (Sweden)

    Shumeyko Victor

    2017-01-01

    Full Text Available Tall buildings and skyscrapers perceive significant vertical loads and, moreover, have to resist large lateral effects which form strong gusts of wind and seismic events. In the world for the high-rise buildings with the nuclei of the stiffness are using streamers – outriggers, which connect the external column and the core form the support system and resist lateral loads. High-rise buildings construction grows promptly around the world and causes new problems which shall be solved on the basis of the modern constructive opportunities, by means of exact engineering assessment. Systems of outrigers and belts are very important in the modern engineering, because they provide effective control over side shifts of a building. They play an important role in high-rise unique buildings constructions, being a link between the central kernel and outer columns. The article deals with the design scheme of conventional conveyor of belts and outriggers – bandages, explores their applications, advantages and disadvantages of various options, problems with their design. Presented material enables the design of unique high-rise buildings to choose the most optimal design solution.

  9. Study on rapid evacuation in high-rise buildings

    Directory of Open Access Journals (Sweden)

    Xin Zhang

    2017-06-01

    Full Text Available More and more high rising buildings emerged in modern cities, but emergency evacuation of tall buildings has been a worldwide difficult problem. In this paper, a new evacuation device for high rising buildings in fire accident was proposed and studied. This device mainly consisted of special spiral slideway and shunt valve. People in this device could fast slide down to the first floor under gravity without any electric power and physical strength, which is suitable for various emergency evacuation including mobility-impaired persons. The plane simulation test has shown that human being in alternative clockwise and counterclockwise movement will not become dizzy. The evacuated people should wear protection pad, which can prevent slider from being injured by surface friction with the slide, and eliminate the friction coefficient difference caused by different clothes and slide surface. The calculation results show that the evacuation speed of the new device is much faster than traditional staircases. Moreover, such new evacuation device can also be used as a means of vertical transportation in high-rise buildings partly. People can take it from any floor to ground floor directly, which not only save time for waiting for the lifts but also save the power. The new evacuation system is of simple structure, easy to use, and suitable for evacuation and partly used as vertical downwards traffic, which shows light on solving world-wide difficulties on fast evacuation in high-rise buildings.

  10. Accidents Preventive Practice for High-Rise Construction

    Directory of Open Access Journals (Sweden)

    Goh Kai Chen

    2016-01-01

    Full Text Available The demand of high-rise projects continues to grow due to the reducing of usable land area in Klang Valley, Malaysia. The rapidly development of high-rise projects has leaded to the rise of fatalities and accidents. An accident that happened in a construction site can cause serious physical injury. The accidents such as people falling from height and struck by falling object were the most frequent accidents happened in Malaysian construction industry. The continuous growth of high-rise buildings indicates that there is a need of an effective safety and health management. Hence, this research aims to identify the causes of accidents and the ways to prevent accidents that occur at high-rise building construction site. Qualitative method was employed in this research. Interview surveying with safety officers who are involved in highrise building project in Kuala Lumpur were conducted in this research. Accidents were caused by man-made factors, environment factors or machinery factors. The accidents prevention methods were provide sufficient Personal Protective Equipment (PPE, have a good housekeeping, execute safety inspection, provide safety training and execute accidents investigation. In the meanwhile, interviewees have suggested the new prevention methods that were develop a proper site layout planning and de-merit and merit system among sub-contractors, suppliers and even employees regarding safety at workplace matters. This research helps in explaining the causes of accidents and identifying area where prevention action should be implemented, so that workers and top management will increase awareness in preventing site accidents.

  11. Wind-induced Dynamic Response of High Rise Buildings

    OpenAIRE

    Bjørnland, Karl Hermann Mathias

    2013-01-01

    This thesis aims to investigate the dynamic response of a high rise concrete structure. Calculations are performed for Lerkendal Hotel, a slender 75 meter high building located in Trondheim. Buffeting response has been the main focus in the calculations, and both displacements, accelerations and cross sectional forces have been obtained.Initially, acceleration demands regarding human comfort in a structure subjected to wind induced vibrations were established using design codes. In addition, ...

  12. Morphology of Shatsky Rise oceanic plateau from high resolution bathymetry

    Science.gov (United States)

    Zhang, Jinchang; Sager, William W.; Durkin, William J.

    2017-06-01

    Newly collected, high resolution multi-beam sonar data are combined with previous bathymetry data to produce an improved bathymetric map of Shatsky Rise oceanic plateau. Bathymetry data show that two massifs within Shatsky Rise are immense central volcanoes with gentle flank slopes declining from a central summit. Tamu Massif is a slightly elongated, dome-like volcanic edifice; Ori Massif is square shaped and smaller in area. Several down-to-basin normal faults are observed on the western flank of the massifs but they do not parallel the magnetic lineations, indicating that these faults are probably not related to spreading ridge faulting. Moreover, the faults are observed only on one side of the massifs, which is contrary to expectations from a mechanism of differential subsidence around the massif center. Multi-beam data show many small secondary cones with different shapes and sizes that are widely-distributed on Shatsky Rise massifs, which imply small late-stage magma sources scattered across the surface of the volcanoes in the form of lava flows or explosive volcanism. Erosional channels occur on the flanks of Shatsky Rise volcanoes due to mass wasting and display evidence of down-slope sediment movement. These channels are likely formed by sediments spalling off the edges of summit sediment cap.

  13. High-rise Buildings versus Outdoor Thermal Environment in Chongqing.

    Science.gov (United States)

    Lu, Jun; Chen, Jin-Hua; Tang, Ying; Wang, Jin-Sha

    2007-10-11

    This paper gives a brief description of the over quick urbanization sinceChongqing, one of the biggest cities in China, has been a municipality directly under theCentral Government in 1997, excessive development and exceeding increase of high-risebuildings because of its special geographical position which finally leads to the worseningof the urban outdoor thermal environment. Then, this paper makes a bright balance to thefield measurement and simulated results of the wind speed field, temperature field of onemultifunctional high-rise building in Chongqing university located in the city center, andthe contrasted results validate the correctness of CFD in the outdoor thermal environmentalsimulation, expose the disadvantages of high-rise buildings on the aspects of blocking thewind field, decreasing wind speed which results in accumulation of the air-conditioningheat revolving around and periscian region where sunshine can not rip into. Finally, inorder to improve the urban outdoor thermal environment near the high-rise buildingsespecially for the angle of natural ventilation, this paper simulates the wind environment indifferent architectural compositions and architectural layouts by CFD, and the simulatedresults show that freestyle and tower buildings which can guarantee the wind speed andtake the air-conditioning heat away are much suitable and reasonable for the specialChongqing geography. These conclusions can also be used as a reference in othermountain cities, especially for the one with a great number of populations.

  14. High-rise Buildings versus Outdoor Thermal Environment in Chongqing

    Directory of Open Access Journals (Sweden)

    Jin-sha Wang

    2007-10-01

    Full Text Available This paper gives a brief description of the over quick urbanization sinceChongqing, one of the biggest cities in China, has been a municipality directly under theCentral Government in 1997, excessive development and exceeding increase of high-risebuildings because of its special geographical position which finally leads to the worseningof the urban outdoor thermal environment. Then, this paper makes a bright balance to thefield measurement and simulated results of the wind speed field, temperature field of onemultifunctional high-rise building in Chongqing university located in the city center, andthe contrasted results validate the correctness of CFD in the outdoor thermal environmentalsimulation, expose the disadvantages of high-rise buildings on the aspects of blocking thewind field, decreasing wind speed which results in accumulation of the air-conditioningheat revolving around and periscian region where sunshine can not rip into. Finally, inorder to improve the urban outdoor thermal environment near the high-rise buildingsespecially for the angle of natural ventilation, this paper simulates the wind environment indifferent architectural compositions and architectural layouts by CFD, and the simulatedresults show that freestyle and tower buildings which can guarantee the wind speed andtake the air-conditioning heat away are much suitable and reasonable for the specialChongqing geography. These conclusions can also be used as a reference in othermountain cities, especially for the one with a great number of populations.

  15. VERTICAL LINEAR PROJECT SCHEDULING FOR HIGH-RISE BUILDINGS

    Directory of Open Access Journals (Sweden)

    İlker ÖZDEMİR

    1999-02-01

    Full Text Available In this paper, an application to high-rise buildings of VPM (Vertical Production Method and an example will be given which is composition of two distinct and preferable methods are CPM (Critical Path Method that is prefering against traditional Bar-Charts or schedules especially in big and costly investments and LOB (Line of Balance technique that is suitable for using in linear project planning. Thus, it could be expected that to show the way of the method to designer and manufacturer about subjects which are activity, priority and sequencing of high-rise project, speeds of activity and construction, completion times, to add or take out some terms to schedule at the state of project changing.

  16. Building America Top Innovations 2014 Profile: ASHRAE Standard 62.2. Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-11-01

    This 2014 Top Innovations profile describes Building America research and support in developing and gaining adoption of ASHRAE 62.2, a residential ventilation standard that is critical to transforming the U.S. housing industry to high-performance homes.

  17. ECOSUSTAINABLE HIGH-RISE : The Environmentally Conscious Architecture of Skyscraper

    Directory of Open Access Journals (Sweden)

    Jimmy Priatman

    2000-01-01

    Full Text Available The term " green architecture " is related to evolving architecture which is sensitive to the environment and emerges from the environmental awareness due to the effects of destruction of air, water, energy and earth. It is characterized by improving energy efficiency, sustainability concept and holistic approach of the entire building enterprise, where all of the environmental factors are regarded as an objective. Although there are many of environmentally conscious architectural works today, but most of the building designers prefer to deal primarily with small-scale buildings (low to medium rise and often only in greenfield, rural or suburban sites. All those large scale, high-rise or tall buildings located in dense urban areas are regarded as avoidable objects that consumes a lot of energy, uses huge amounts of materials, and produces massive volumes of waste discharge into the environment. These intensive buildings deserve greater attention and should be designed by greater part of our expertise and effort to ecologically design than the smaller buildings with fewer problems. The paper discusses "green" dimensions applied to tall buildings/high-rise buildings with their innovative approach that leads to ecosustainable tall buildings.

  18. Reduction of temperature rise in high-speed photography

    Science.gov (United States)

    Slater, Howard A.

    1988-01-01

    Information is provided on filtration with glass and infrared absorbing and reflecting filters. Glass and infrared filtration is a simple and effective method to reduce the radiation heat transfer associated with continuous high intensity tungsten lamps. The results of a filtration experiment are explained. The figures provide starting points for quantifying the effectiveness of various filters and associated light intensities. The combination of a spectrally selective reflector (hot or cold mirror) based on multilayer thin film principles and heat absorbing or infrared opaque glass results in the maximum reduction in temperature rise with a minimum of incident light loss. Use is recommended of a voltage regulator to further control temperature rise and incident light values.

  19. A Review on Natural Ventilation-enabling Façade Noise Control Devices for Congested High-Rise Cities

    Directory of Open Access Journals (Sweden)

    Shiu-Keung Tang

    2017-02-01

    Full Text Available This review summarizes the current status of the research and development of natural ventilation-enabling noise control devices for use on the façades of high-rise residential buildings in congested cities. These devices are important for a sustainable urbanized city, as they are supposed to offer good acoustical protection to citizens, allowing for an acceptable level of natural ventilation inside residential units; energy for mechanical ventilation can then be saved. From the information presented in the existing literature, it is concluded that protrusive devices, such as lintels and balconies, are not effective noise screening devices, even if they are installed with sound absorbers and/or reflectors, under the effect of city reverberation. On the contrary, plenum windows and similar structures, which are plenum structures with a staggered air inlet and outlet, are interesting alternatives that are worth rigorous considerations.

  20. THE FORMATION OF DESIGN AND ORGANIZATIONAL AND TECHNOLOGICAL DECISIONS OF THE CONSTRUCTION OF HIGH-RISE MULTIPURPOSE COMPLEXES

    Directory of Open Access Journals (Sweden)

    BOLSHAKOV V. I.

    2016-05-01

    Full Text Available Purpose. The formation of the many ways the construction of high-rise multipurpose complexes. Methodology. The formation of system implementation variants of creation and functioning of high-rise multipurpose complexes using combinatorial morphological analysis and synthesis. Findings. Many life cycle options of high-rise multipurpose complexes. Originality. The developed method of formation of organizational and technological solutions adapted to the conditions of the construction of high-rise multipurpose complexes, which provides the opportunity for multi-variant conditions, taking into account regulatory requirements for fire safety, insolation of buildings and premises, protection against noise and vibration, energy efficiency, infrastructure and population density of a residential district with a full range of institutions and enterprises of local significance, within existing resource constraints, to ensure the commissioning of objects with specified technical and economic characteristics. Practical value. The proposed model and the methodology allow to determine a rational variant of high-rise building according to specified criteria and constraints.

  1. Effects of high modes on the wind-induced response of super high-rise buildings

    Science.gov (United States)

    Feng, Ruoqiang; Yan, Guirong; Ge, Jinming

    2012-09-01

    For super high-rise buildings, the vibration period of the basic mode is several seconds, and it is very close to the period of the fluctuating wind. The damping of super high-rise buildings is low, so super high-rise buildings are very sensitive to fluctuating wind. The wind load is one of the key loads in the design of super high-rise buildings. It is known that only the basic mode is needed in the wind-response analysis of tall buildings. However, for super high-rise buildings, especially for the acceleration response, because of the frequency amplification of the high modes, the high modes and the mode coupling may need to be considered. Three typical super high-rise projects with the SMPSS in wind tunnel tests and the random vibration theory method were used to analyze the effect of high modes on the wind-induced response. The conclusions can be drawn as follows. First, for the displacement response, the basic mode is dominant, and the high modes can be neglected. Second, for the acceleration response, the high modes and the mode coupling should be considered. Lastly, the strain energy of modes can only give the vibration energy distribution of the high-rise building, and it cannot describe the local wind-induced vibration of high-rise buildings, especially for the top acceleration response.

  2. Investigation of wind behaviour around high-rise buildings

    Science.gov (United States)

    Mat Isa, Norasikin; Fitriah Nasir, Nurul; Sadikin, Azmahani; Ariff Hairul Bahara, Jamil

    2017-09-01

    A study on the investigation of wind behaviour around the high-rise buildings is done through an experiment using a wind tunnel and computational fluid dynamics. High-rise buildings refer to buildings or structures that have more than 12 floors. Wind is invisible to the naked eye; thus, it is hard to see and analyse its flow around and over buildings without the use of proper methods, such as the use of wind tunnel and computational fluid dynamics software.The study was conducted on buildings located in Presint 4, Putrajaya, Malaysia which is the Ministry of Rural and Regional Development, Ministry of Information Communications and Culture, Ministry of Urban Wellbeing, Housing and Local Government and the Ministry of Women, Family, and Community by making scaled models of the buildings. The parameters in which this study is conducted on are, four different wind velocities used based on the seasonal monsoons, and wind direction. ANSYS Fluent workbench software is used to compute the simulations in order to achieve the objectives of this study. The data from the computational fluid dynamics are validated with the experiment done through the wind tunnel. From the results obtained through the use of the computation fluid dynamics, this study can identify the characteristics of wind around buildings, including boundary layer of the buildings, separation flow, wake region and etc. Then analyses is conducted on the occurance resulting from the wind that passes the buildings based on the velocity difference between before and after the wind passes the buildings.

  3. Optimization of water distribution systems in high-rise buildings

    Energy Technology Data Exchange (ETDEWEB)

    Loh, Han Tong; Chew, T.C.

    1994-12-31

    The scarcity of land in Singapore has led to a rapid escalation of land prices in recent years. This has resulted in developers building taller and taller buildings in order to maximize their return on building projects. Due to the height involved, the water distribution system in such buildings is a multi-stage one. Hence the problem of deciding the number of stages and the location of each stage arises. In this paper, we will describe the design decisions to be taken in the preliminary design of a multi-stage water distribution system in a high-rise building and pose it as an optimization problem to minimize the overall cost of implementation. The variable costcomponents are the cost of pumps, the floor space cost and the operational cost of the water distribution system. We will describe a study on a 66-story building and highlight the major findings. Interesting results are observed when the cost components are taken one at a time. The strategy for finding the optimum or near optimum for other high-rise buildings will be discussed.

  4. Radon action level for high-rise buildings

    Energy Technology Data Exchange (ETDEWEB)

    Leung, J.K.C.; Tso, M.Y.W.; Ho, C.W. (Univ. of Hong Kong (Hong Kong). Radioisotope Unit)

    1999-05-01

    Radon and its progeny are the major contributors to the natural radiation dose received by human beings. Many countries and radiological authorities have recommended radon action levels to limit the indoor radon concentrations, and, hence, the annual doses to the general public. Since the sources of indoor radon and the methods for reducing its concentration are different for different types of buildings, social and economic factors have to be considered when setting the action level. But so far no action levels are specifically recommended for cities that have dwellings and offices all housed in high-rise buildings. In this study, an optimization approach was used to determine an action level for high-rise buildings based on data obtained through previous territory-wide radon surveys. A protection cost of HK $0.044 per unit fresh air change rate per unit volume and a detriment cost of HK $120,000 per person-Sv were used, which gave a minimum total cost at an action level of 200 Bq m[sup [minus]3]. The optimization analyses were repeated for different simulated radon distributions and living environment, which resulted in quite significantly different action levels. Finally, an action level of 200 Bq m[sup [minus]3] was recommended for existing buildings and 150 Bq m[sup [minus]3] for newly built buildings.

  5. Magnetic field management of substations in high rise buildings

    Energy Technology Data Exchange (ETDEWEB)

    Farag, A.S.; Al-Shehri, A.M. [King Fahd Univ. of Petroleum and Minerals, Dhahran (Saudi Arabia); Cheng, T.C.; Du, Y.; Hu, L.; Penn, D. [Univ. of Southern California, LADWP, Los Angeles, CA (United States)

    1995-12-01

    The electric and magnetic field issue has become an area of increasing public concern. Utilities have been carrying out extensive projects to characterize and manage the magnetic fields around their substations in an effort to answer public concerns over the possible health hazard caused by these fields. This paper describes various techniques available for managing magnetic field strength levels in substations. The design guideline aids in the planning, design, construction of substation facilities. Low-frequency magnetic field is directly associated with current-carrying sources and its magnitude is proportional to the distance from the sources. Distribution substations in high-rise buildings are very close to public areas and the magnetic fields imposed by these substations might be relatively higher than that imposed by outdoor substations. Options to manage these substations fields are considered in this paper. Techniques to manage magnetic fields in substations such as: source relocation, compaction, rephasing, return-current control, passive and active shielding are discussed. Several techniques were applied to reduce the magnetic fields in the conference room located in the main floor above a substation located in the basement of the main office high-rise building of LADWP. 10 refs, 14 figs, 3 tabs

  6. Radon action level for high-rise buildings.

    Science.gov (United States)

    Leung, J K; Tso, M Y; Ho, C W

    1999-05-01

    Radon and its progeny are the major contributors to the natural radiation dose received by human beings. Many countries and radiological authorities have recommended radon action levels to limit the indoor radon concentrations and, hence, the annual doses to the general public. Since the sources of indoor radon and the methods for reducing its concentration are different for different types of buildings, social and economic factors have to be considered when setting the action level. But so far no action levels are specifically recommended for cities that have dwellings and offices all housed in high-rise buildings. In this study, an optimization approach was used to determine an action level for high-rise buildings based on data obtained through previous territory-wide radon surveys. A protection cost of HK$0.044 per unit fresh air change rate per unit volume and a detriment cost of HK$120,000 per person-Sv were used, which gave a minimum total cost at an action level of 200 Bq m(-3). The optimization analyses were repeated for different simulated radon distributions and living environment, which resulted in quite significantly different action levels. Finally, an action level of 200 Bq m(-3) was recommended for existing buildings and 150 Bq m(-3) for newly built buildings.

  7. On methods of sustainable architectural design of bio-positive buildings in the low-rise residential development structure

    Directory of Open Access Journals (Sweden)

    Zhogoleva Anna

    2017-01-01

    Full Text Available The purpose of the author’s research is to determine the actual content of sustainable architectural design for suburban residential development. In accordance with the methodology of area sustainable development the traditional architectural design according to the rules and regulations is completed with additional approaches and methods. As a result, methods of bio-positive design of buildings have been studied and defined, including: the principle of planning transformations, the use of environmentally friendly, local building materials and design concepts, energy-efficient architectural design, the use of alternative energy in building operation, the design of the energy intake and accumulationsystems, the architectural and landscape design that ensures stable functioning of autonomous, sustainable biosystems on the site, non-waste functioning of architectural objects, introduction of waste disposal systems in the project.

  8. Mass exchanger for high-rise buildings with aquifer storage

    Energy Technology Data Exchange (ETDEWEB)

    Tolido, H.W.A.; Veltkamp, W.B.; Schaap, A.B. [LEVEL Energy Technology, Son (Netherlands)

    1994-12-31

    Aquifer storage systems are used to withdraw cold in summer and heat in winter. In high-rise buildings the technical installations are preferably placed on the top floor and so water from the aquifer has to be pressurised. Heat is absorbed or released here and the water returns to the aquifer. To recover potential energy from the pressurised water a turbine-pump combination may be used or the high pressure circuit is separated from the low pressure circuit by a heat exchanger. Van Berkel (1991) found that turbine-pump combinations recover only about 25-40 % of the potential energy. Application of a heat exchanger typically shows a thermal efficiency of 80 %. The proposed mass exchanger combines pressure separation with high effective heat transport. The high pressure circuit in the building and the low pressure aquifer circuit, are separated by a rotating element with rotation symmetric distributed chambers. Chunks of water are cut from the high pressure circuit and rotated into the low pressure circuit while at the same time an equal amount of water is transported from the low into the high pressure circuit. In these chambers also separation of warm and cold water is realised, due to the plug flow. Testing a scale model demonstrated the feasibility of the design, indicating a pressure recovery and thermal effectivity of the apparatus of 99 % and of 96 %. (orig.)

  9. Quality Assurance Roadmap for High Performance Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    None

    2008-10-05

    This report outlines the approach to quality assurance in the construction process for new residential construction, including seven process steps from the assessment of current construction practice, through design and documentation changes, to training and quality control for on-site personnel.

  10. Residential land values and their determinants in high density ...

    African Journals Online (AJOL)

    Among urbanization and residential land use problems identified by the study are poor level of social and technical infrastructure, poor land and city management system capacity, ... Cette recherche fait l'analyse des valeurs des terrains dans les quartiers résidentiels à forte densité de population du métropole de Lagos.

  11. Potential for rainwater use in high-rise buildings in Australian cities.

    Science.gov (United States)

    Zhang, Yan; Chen, Donghui; Chen, Liang; Ashbolt, Stephanie

    2009-10-01

    Rainwater is a traditional but underutilized water resource that has today had a resurgence due to the worldwide water crisis. This paper demonstrates the outcomes of research on the feasibility of rainwater use in high-rise residential envelopes for four Australian cities of Melbourne, Sydney, Perth and Darwin. Different climate patterns and various levels of water demand management were established for determination of storage dimensions; annual tank water use; reduction in both imported water flow and stormwater disposal; and water spillage from tanks. High level water demand management was a profoundly effective tool for reducing potable water supply, especially in combination with rainwater use. The economic feasibility of rainwater use systems were estimated; with Sydney having the shortest payback period compared to other cities either both with 3A rated appliances (8.6 years) or 5A ones installed (10.4 years). That was due to the higher and more consistent rainfall in Sydney. An outcome of this study was that Sydney was likely most suited to rainwater use, followed by Perth, Darwin, and then Melbourne. The objective of this study was to fill in the gap in estimating feasibility of rainwater use in various Australian cities. This investigation endeavors to provide assistance to water authorities and urban planners of Australian cities with the consideration of the potential of rainwater harvesting.

  12. Waste generated in high-rise buildings construction: a quantification model based on statistical multiple regression.

    Science.gov (United States)

    Parisi Kern, Andrea; Ferreira Dias, Michele; Piva Kulakowski, Marlova; Paulo Gomes, Luciana

    2015-05-01

    Reducing construction waste is becoming a key environmental issue in the construction industry. The quantification of waste generation rates in the construction sector is an invaluable management tool in supporting mitigation actions. However, the quantification of waste can be a difficult process because of the specific characteristics and the wide range of materials used in different construction projects. Large variations are observed in the methods used to predict the amount of waste generated because of the range of variables involved in construction processes and the different contexts in which these methods are employed. This paper proposes a statistical model to determine the amount of waste generated in the construction of high-rise buildings by assessing the influence of design process and production system, often mentioned as the major culprits behind the generation of waste in construction. Multiple regression was used to conduct a case study based on multiple sources of data of eighteen residential buildings. The resulting statistical model produced dependent (i.e. amount of waste generated) and independent variables associated with the design and the production system used. The best regression model obtained from the sample data resulted in an adjusted R(2) value of 0.694, which means that it predicts approximately 69% of the factors involved in the generation of waste in similar constructions. Most independent variables showed a low determination coefficient when assessed in isolation, which emphasizes the importance of assessing their joint influence on the response (dependent) variable. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Urban renewal: strategies for high density residential suburbs regeneration

    Directory of Open Access Journals (Sweden)

    Andrea Boeri

    2012-10-01

    Full Text Available This article summarizes the main results of a research conducted by the University of Bologna, Department of Architecture, within the framework of the Research Program PRIN 2008, «Renovation, regeneration and valorisation of social housing settlements built in the suburban areas in the second half of last century». Once quantified the residential stock, a methodology for multidisciplinary analysis, applied to a specific case study (the district of Pilastro in Bologna, aimed at evaluating the different complementary aspects of building quality (social, functional, technical and environmental ones was developed with the objective of formulating strategies of intervention and models aimed at reducing the problems detected.

  14. Distribution trend of high-rise buildings worldwide and factor exploration

    Science.gov (United States)

    Yu, Shao-Qiao

    2017-08-01

    This paper elaborates the development phenomenon of high-rise buildings nowadays. The development trend of super high-rise buildings worldwide is analyzed based on data from the Council on Tall Buildings and Urban Habitat, taking the top 100 high-rise buildings in different continents and with the time development and building type as the objects. Through analysis, the trend of flourishing of UAE super high-rise buildings and stable development of European and American high-rise buildings is obtained. The reasons for different development degrees of the regions are demonstrated from the aspects of social development, economy, culture and consciousness. This paper also presents unavoidable issues of super high-rise buildings and calls for rational treatment to these buildings.

  15. From real estate market to the habitability of residential space

    OpenAIRE

    Mejía Escalante, Mónica Elizabeth

    2010-01-01

    The constant construction of closed high-rise residential areas are not an isolated event produced solely by a group of investors to activate a real estate dynamic, their current space characteristics, the used constructive system and the residential tendency that has been configured, is not only consequent with the planning guidelines for a city like Medellín, but the rise of a proposal of mass dissemination, from a profusion of advertising devices as barriers, steering wheels, magazines of ...

  16. Residential independence of former special education high school students: a second look.

    Science.gov (United States)

    Heal, L W; Rubin, S S; Rusch, F R

    1998-01-01

    The residential independence of postsecondary students was assessed in 5,462 parents or surrogate parents of students with disabilities from the National Longitudinal Transition Study who had left United States high schools between 1985 and the time of the questionnaire in 1990. An index of residential placement independence served as the dependent variable in a hierarchical regression analysis that featured 43 community, family, student, and school program characteristics entered as block-wise predictors (i.e., entered in a controlled order). This analysis produced a multiple R2 of .376: missing data, youths' daily living skills, youths' social skills, youths' maladaptive ("problem") behaviors, and community characteristics all contributed significantly to the prediction of the postschool residential independence of former special education students during the first 5 years after they had left secondary school.

  17. High tides and rising seas: potential effects on estuarine waterbirds

    Science.gov (United States)

    Erwin, R.M.; Sanders, G.M.; Prosser, D.J.; Cahoon, D.R.; Greenberg, Russell; Maldonado, Jesus; Droege, Sam; McDonald, M.V.

    2006-01-01

    Coastal waterbirds are vulnerable to water-level changes especially under predictions of accelerating sea-level rise and increased storm frequency in the next century. Tidal and wind-driven fluctuations in water levels affecting marshes, their invertebrate communities, and their dependent waterbirds are manifested in daily, monthly, seasonal, annual, and supra-annual (e.g., decadal or 18.6-yr) periodicities. Superimposed on these cyclic patterns is a long-term (50?80 yr) increase in relative sea-level rise that varies from about 2?4 + mm/yr along the Atlantic coastline. At five study sites selected on marsh islands from Cape Cod, Massachusetts to coastal Virginia, we monitored marsh elevation changes and flooding, tide variations over time, and waterbird use. We found from longterm marsh core data that marsh elevations at three of five sites may not be sufficient to maintain pace with current sea-level rise. Results of the short-term (3?4 yr) measures using surface elevation tables suggest a more dramatic difference, with marsh elevation change at four of five sites falling below relative sea-level rise. In addition, we have found a significant increase (in three of four cases) in the rate of surface marsh flooding in New Jersey and Virginia over the past 70?80 yr during May?July when waterbirds are nesting on or near the marsh surface. Short-term, immediate effects of flooding will jeopardize annual fecundity of many species of concern to federal and state agencies, most notably American Black Duck (Anas rubripes), Nelson?s Sharp-tailed Sparrow (Ammodramus nelsoni), Saltmarsh Sharp-tailed Sparrow (A. caudacutus), Seaside Sparrow (A. maritima), Coastal Plain Swamp Sparrow (Melospiza georgiana nigrescens), Black Rail (Laterallus jamaicensis), Forster?s Tern (Sterna forsteri), Gull-billed Tern (S. nilotica), Black Skimmer (Rynchops niger), and American Oystercatcher (Haemotopus palliatus). Forster?s Terns are probably most at risk given the large proportion of their

  18. Early Reading Skills and Academic Achievement Trajectories of Students Facing Poverty, Homelessness, and High Residential Mobility

    Science.gov (United States)

    Herbers, Janette E.; Cutuli, J. J.; Supkoff, Laura M.; Heistad, David; Chan, Chi-Keung; Hinz, Elizabeth; Masten, Ann S.

    2012-01-01

    This investigation tested the importance of early academic achievement for later achievement trajectories among 18,011 students grouped by level of socioeconomic risk. Students considered to be at highest risk were those who experienced homelessness or high residential mobility (HHM). HHM students were compared with students eligible for free…

  19. Prevalence of Weight Problems among Youth with High-Incidence Disabilities in Residential Care

    Science.gov (United States)

    Trout, Alexandra L.; Lambert, Matthew C.; Nelson, Timothy D.; Thompson, Ronald W.

    2014-01-01

    The prevalence of weight problems among youth in general and youth in out-of-home care has been well documented; however, the prevalence of obesity/overweight among youth with high-incidence disabilities in more restrictive settings, such as residential care, has not been assessed. The purpose of the present study was to evaluate the prevalence of…

  20. Analysis of wind-induced vibrations in high-rise buildings

    DEFF Research Database (Denmark)

    Persson, Peter; Austrell, Per-Erik; Kirkegaard, Poul Henning

    2016-01-01

    . The paper summarises acceptable acceleration levels in high -rise buildings (here referred to as buildings over 200 m in height) stated in different building codes and previous work on the subject. Accelerations of a high-rise building subjected to wind-loads are evaluated using a full numerical model...

  1. Fire Problems in High-Rise Buildings. California Fire Service Training Program.

    Science.gov (United States)

    California State Dept. of Education, Sacramento. Bureau of Industrial Education.

    Resulting from a conference concerned with high-rise fire problems, this manual has been prepared as a fire department training manual and as a reference for students enrolled in fire service training courses. Information is provided for topics dealing with: (1) Typical Fire Problems in High-Rise Buildings, (2) Heat, (3) Smoke and Fire Gases, (4)…

  2. SEISMIC Analysis of high-rise buildings with composite metal damper

    Directory of Open Access Journals (Sweden)

    Chen Ruixue

    2015-01-01

    Full Text Available This paper mainly studies on the mechanical characteristics and application effect of composite metal damper in the high-rise buildings via the numerical simulation analysis. The research adopts the elastic and elastic-plastic dynamic approach and the displacement time history response and damper energy dissipation capacity and so on of the high-rise building are compared and analyzed before and after installation. The analysis found that the energy dissipation characteristic of metallic dampers is good. High-rise building story drift significantly is reduced and the extent of damage of the walls and coupling beams is decreased, achieved a good energy dissipation effect. Composite metal damper can effectively and economically improve the seismic performance of high-rise buildings, meet the requirement of the 3-level design for seismic resistance. The result has certain reference significance for the application of metallic damper in the high-rise buildings.

  3. High-Rise Refurbishment: The Energy-Efficient Upgrade of Multi-Story Residences in the European Union

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    Some 36 million European households are in high-rise residences, one in six of all households, and yet many of the buildings are in urgent need of refurbishment. This study, which is one in a series being conducted on behalf of the International Energy Agency addressing the energy performance of the existing IEA-wide building stock, identifies a Europe-wide cost-effective energy saving potential of 28% from energy-efficient refurbishment of the high-rise residential building stock. Attainment of this potential would imply a 1.5% reduction of Europe's total final energy demand and annual CO2 emissions savings of 35 Mt. In practice only the less efficient buildings need to be refurbished to realise these stockaverage savings and for these buildings typical savings in heating energy from refurbishment of between 70 and 80% are identified. Buildings in general suffer from a variety of barriers that tend to prevent their occupants from maintaining and refurbishing them to levels of comfort and energy performance that would be justified over the longer term, but collective housing in general is particularly susceptible to market failures. Many occupants do not own the property while their landlords usually have little motivation to finance improvements. Refurbishment requires collective agreement on a capital investment, which is difficult to establish especially when some occupants expect to live in the building over the longer-term but others only for the short-term. Furthermore, in most cases the occupants of high-rise residences are not among the wealthier members of society and they find it difficult to raise capital for longer-term investments. It is not surprising, then, to find that this section of the building stock is the most neglected and that there remain significant cost-effective opportunities for it to be refurbished in a way that improves comfort, saves energy, reduces CO2 emissions and significantly improves the urban environment.

  4. Out-of-hospital cardiac arrest in high-rise buildings: delays to patient care and effect on survival.

    Science.gov (United States)

    Drennan, Ian R; Strum, Ryan P; Byers, Adam; Buick, Jason E; Lin, Steve; Cheskes, Sheldon; Hu, Samantha; Morrison, Laurie J

    2016-04-05

    The increasing number of people living in high-rise buildings presents unique challenges to care and may cause delays for 911-initiated first responders (including paramedics and fire department personnel) responding to calls for out-of-hospital cardiac arrest. We examined the relation between floor of patient contact and survival after cardiac arrest in residential buildings. We conducted a retrospective observational study using data from the Toronto Regional RescuNet Epistry database for the period January 2007 to December 2012. We included all adult patients (≥ 18 yr) with out-of-hospital cardiac arrest of no obvious cause who were treated in private residences. We excluded cardiac arrests witnessed by 911-initiated first responders and those with an obvious cause. We used multivariable logistic regression to determine the effect on survival of the floor of patient contact, with adjustment for standard Utstein variables. During the study period, 7842 cases of out-of-hospital cardiac arrest met the inclusion criteria, of which 5998 (76.5%) occurred below the third floor and 1844 (23.5%) occurred on the third floor or higher. Survival was greater on the lower floors (4.2% v. 2.6%, p = 0.002). Lower adjusted survival to hospital discharge was independently associated with higher floor of patient contact, older age, male sex and longer 911 response time. In an analysis by floor, survival was 0.9% above floor 16 (i.e., below the 1% threshold for futility), and there were no survivors above the 25th floor. In high-rise buildings, the survival rate after out-of-hospital cardiac arrest was lower for patients residing on higher floors. Interventions aimed at shortening response times to treatment of cardiac arrest in high-rise buildings may increase survival. © 2016 Canadian Medical Association or its licensors.

  5. High-Arctic butterflies become smaller with rising temperatures

    DEFF Research Database (Denmark)

    Bowden, Joseph James; Eskildsen, Anne; Hansen, Rikke Reisner

    2015-01-01

    size but long growing seasons could also increase body size as was recently shown in an Arctic spider species. Here, we present the longest known time series on body size variation in two High-Arctic butterfly species: Boloria chariclea and Colias hecla. We measured wing length of nearly 4500...

  6. High-rise Buildings versus Outdoor Thermal Environment in Chongqing

    OpenAIRE

    Lu, Jun; Chen, Jin-hua; Tang, Ying; Wang, Jin-sha

    2007-01-01

    This paper gives a brief description of the over quick urbanization sinceChongqing, one of the biggest cities in China, has been a municipality directly under theCentral Government in 1997, excessive development and exceeding increase of high-risebuildings because of its special geographical position which finally leads to the worseningof the urban outdoor thermal environment. Then, this paper makes a bright balance to thefield measurement and simulated results of the wind speed field, temper...

  7. Greening the high-rises: An essay on the different possibilities of using green in high-rise buildings in China

    NARCIS (Netherlands)

    Schut, E.

    2011-01-01

    This paper is written for the TIDO-course AR0532 Smart & Bioclimatic Design Theory. In this paper are discussed the specific characteristics of the climate in Chengdu, the effects of green on the quality of life in the built environment en the possibilities for integrating green in high-rise

  8. Laser heterodyne interferometric signal processing method based on rising edge locking with high frequency clock signal.

    Science.gov (United States)

    Zhang, Enzheng; Chen, Benyong; Yan, Liping; Yang, Tao; Hao, Qun; Dong, Wenjun; Li, Chaorong

    2013-02-25

    A novel phase measurement method composed of the rising-edge locked signal processing and the digital frequency mixing is proposed for laser heterodyne interferometer. The rising-edge locked signal processing, which employs a high frequency clock signal to lock the rising-edges of the reference and measurement signals, not only can improve the steepness of the rising-edge, but also can eliminate the error counting caused by multi-rising-edge phenomenon in fringe counting. The digital frequency mixing is realized by mixing the digital interference signal with a digital base signal that is different from conventional frequency mixing with analogue signals. These signal processing can improve the measurement accuracy and enhance anti-interference and measurement stability. The principle and implementation of the method are described in detail. An experimental setup was constructed and a series of experiments verified the feasibility of the method in large displacement measurement with high speed and nanometer resolution.

  9. [On the evaluation of health factors in high-rise buildings. 3. Sociological investigations and questioning of physicians about living in high-rise buildings (author's transl)].

    Science.gov (United States)

    Freisitzer, K; Möse, J R

    1981-01-01

    It can be rightly assumed that there are persons who evidently prefer to live in high-rise buildings. They should not be prevented from doing so as long as no evidence is produced that this preference neither does any serious harm to the people concerned nor causes any major risk of damage to the community. To our knowledge, accurate and sufficiently extensive empirical investigations have not yet been undertaken. One cannot help feeling that general shortcomings (e.g. inadequate town planning, housing planning, workmanship etc.) lead to a hunt for scapegoats. The high-rise building appears to be a rewarding object for such intentions. There is conclusive evidence that dwellings of good and poor quality exist. Both can be found in the detached single-family house and in the tower block. What has to be claimed is mainly a good location and good workmanship, for both are much more important than the type of the dwelling. The most striking deficiencies which were found in the high-rise buildings of Graz are mistaken selection of the location and poor workmanship. The improvement of the living conditions of a larger number of people will therefore depend more on the elimination of these shortcomings rather than on the promotion of certain types of dwelling. Subsequent to these sociological investigations, a physician questioned the general practitioners prevailingly attending to tenants of the high-rise buildings under study. There is no trend toward an increased incidence of objectively determinable diseases among the people living on the upper storeys of the high-rise buildings under review. This holds good for both the adults and the children. By contrast, the factor "noise" evidently influences health to some extent. The influence of this factor is partly so overrated that it outweighs, in particularly severe cases, any other adverse environmental condition.

  10. Analysis of highly-efficient electric residential HPWHs

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D [ORNL; Murphy, Richard W [ORNL; Rice, C Keith [ORNL; Shen, Bo [ORNL; Gao, Zhiming [ORNL

    2011-09-01

    A scoping level analysis was conducted to identify electric HPWH concepts that have the potential to achieve or exceed 30% source energy savings compared to a gas tankless water heater (GTWH) representative of the type represented in version 0.9.5.2 beta of the BEopt software developed by the National Renewable Energy Laboratory. The analysis was limited to evaluation of options to improve the energy efficiency of electric HPWH product designs currently on the market in the US. The report first defines the baseline GTWH system and determines its efficiency (source-energy-based adjusted or derated EF of ~0.71). High efficiency components (compressors, pumps, fans, heat exchangers, etc.) were identified and applied to current US HPWH products and analyzed to determine the viability of reaching the target EF. The target site-based energy factor (EF) required for an electric HPWH necessary to provide 30% source energy savings compared to the GTWH baseline unit is then determined to be ~3.19.

  11. Stroke Risk Can Rise with Pregnancy-Linked High Blood Pressure

    Science.gov (United States)

    ... page: https://medlineplus.gov/news/fullstory_165944.html Stroke Risk Can Rise With Pregnancy-Linked High Blood ... Several factors raise the risk of pregnancy-related stroke in women with preeclampsia, a new study suggests. ...

  12. Physical modeling of concentration distributions around twin high-rise buildings with a district heating plant

    Energy Technology Data Exchange (ETDEWEB)

    Ohba, M.; Lawson, R.E.

    1993-01-01

    A wind tunnel experiment was conducted to investigate the effects of three high-rise building configurations on the diffusion of emissions released near the downstream base of the buildings. The building configurations included an isolated high-rise building, two high-rise buildings separated in the streamwise direction, and two high-rise buildings separated in the streamwise direction, but situated atop a terrace-shaped lower level. For each configuration, the emission source location, building height and/or building separation was systematically varied while tracer concentration measurements were obtained both downstream and on the surface of the buildings. When the source was within the downwind wake of the twin building models, the source elevation did not strongly influence the building surface distributions although the maximum concentrations appeared at different elevations. Compared to the effect of an isolated building, the twin buildings resulted in higher concentrations in the near-wake of the downwind building.

  13. Investigation of fire-induced collapse scenarios for a steel high-rise building

    DEFF Research Database (Denmark)

    Gentili, Filippo; Giuliani, Luisa; Bontempi, Franco

    2011-01-01

    The paper deals with the problem of understanding and evaluating the structural response of steel buildings to fire and outlines a general framework for the structural fire safety design of high-rise building. Among all building typology, the fire design of high-rise buildings is particularly...... (architectural design choices and active measures) and won’t be investigated in detail in this paper; the paper focus instead on structural design aspects, with specific reference to the iii) enhanced susceptibility of high-rise buildings to disproportionate collapse, due to the significant vertical elevation...... still a relatively low temperature at the time of failure: in this respect, the example of a high rise building is presented in the paper, where, depending on the fire scenarios considered and as different beam-column stiffness ratio, fire damages can remain localized to the heated zone or involve other...

  14. On Roof Geometry for Urban Wind Energy Exploitation in High-Rise Buildings

    National Research Council Canada - National Science Library

    Francisco Toja-Silva; Carlos Peralta; Oscar Lopez-Garcia; Jorge Navarro; Ignacio Cruz

    2015-01-01

    .... The present investigation explores the most adequate roof shapes compatible with the placement of different types of small wind energy generators on high-rise buildings for urban wind energy exploitation...

  15. Heterogeneous Network Evolution Studies for a Dense Urban High Rise Scenario

    DEFF Research Database (Denmark)

    Sanchez, Maria Laura Luque; Maternia, Michal; Vejlgaard, Benny

    2014-01-01

    This paper studies the capability of Long-Term Evolution-Advanced (LTE-A) together with WiFi 802.11ac to accommodate the traffic growths of 80x, 500x and 1000x in a high rise building scenario. It provides a guideline on the configuration of the spectrum and the best deployment options...... coverage and capacity for the future wireless service consumers, specially those located in the high rise buildings....

  16. A Study on Problems Arises in Practicing Fire Drill in High Rise Building in Kuala Lumpur

    Directory of Open Access Journals (Sweden)

    Zahari N.F.

    2014-01-01

    Full Text Available Fire drill is one of the steps taken to mitigate the risk trapped in a building during outbreak of fire. Hence, it is very important for every building to practice fire drill, especially high-rise building. Referring to Fire and Rescue Department of Malaysia(BOMBA, high-rise building had a higher risk compared to other type of buildings. However, there might be problems arise to practice fire drill especially in high-rise building. This research intends to study on fire drill procedure and identify any possible common problems arises when practicing fire drill in high-rise building in Kuala Lumpur. Information was gained through regulations and guidelines associated with fire drill procedure and also parties involved in the practice. Besides, a survey is done for awareness of occupants in high-rise building on fire drill practice. For the case study, three high-rise building are selected in Kuala Lumpur based on specific criteria. Analysis for this research comprises of comparative and descriptive approach as well as statistical analysis which are documented based on case studies and questionnaire survey. The findings indicates that there is no standardized procedure in fire drill, while the most common problems that can be seen in practicing fire drill are lack of commitment among occupants, lack of information on fire drill and output on weaknesses after fire drill been practiced.

  17. High efficiency battery converter with SiC devices for residential PV systems

    DEFF Research Database (Denmark)

    Pham, Cam; Teodorescu, Remus; Kerekes, Tamas

    2013-01-01

    The demand for high efficiency and higher power density is a challenge for Si-based semiconductors due to the physical characteristics of material. These can be overcome by employing wide-band-gap materials like SiC. This paper compares a second generator SiC MOSFETs against a normally-on Trench ...... JFETs and theirs performances in a high efficiency battery converter for residential photovoltaic systems. The prototypes are 3 kW converters with more than 98% efficiency and high simplicity and power density....

  18. Life-Cycle Energy Implications of Downtown High-Rise vs. Suburban Low-Rise Living: An Overview and Quantitative Case Study for Chicago

    OpenAIRE

    Peng Du; Antony Wood; Brent Stephens; Xiaoyu Song

    2015-01-01

    It is commonly accepted that the concentration of people in high-density urban city centers, which are typically dominated by medium- and high-rise buildings located close to public transit systems, offers greater overall energy efficiency and lower life-cycle greenhouse gas emissions than lower-density expanded suburbs, which are dominated by low-rise single-family buildings and larger per-person automobile travel requirements. However, few studies have combined quantitative analyses of the ...

  19. Perbandingan Produktivitas Luffing Crane Dengan Hammer Head Crane Pada Proyek High Rise Building Studi Kasus: Menara Astra Project, Jakarta

    OpenAIRE

    Citra, Putri Lokita Purnama; Sihkawekas, Gloria; Hidayat, Arif; Yuniarto, Rudi

    2016-01-01

    The economic growth has contributed to the increasing number of high rise building construction mostly in big city especially Jakarta. In practice, the construction of high rise building project is aided by heavy equipment that is hammer head crane which is known as one of tower crane type. However, with the increasing number of high rise building construction, the hammer head crane space that usually be used in high rise building project is limited, hence, another type of tower crane called ...

  20. Computer aided seismic and fire retrofitting analysis of existing high rise reinforced concrete buildings

    CERN Document Server

    Hussain, Raja Rizwan; Hasan, Saeed

    2016-01-01

    This book details the analysis and design of high rise buildings for gravity and seismic analysis. It provides the knowledge structural engineers need to retrofit existing structures in order to meet safety requirements and better prevent potential damage from such disasters as earthquakes and fires. Coverage includes actual case studies of existing buildings, reviews of current knowledge for damages and their mitigation, protective design technologies, and analytical and computational techniques. This monograph also provides an experimental investigation on the properties of fiber reinforced concrete that consists of natural fibres like coconut coir and also steel fibres that are used for comparison in both Normal Strength Concrete (NSC) and High Strength Concrete (HSC). In addition, the authors examine the use of various repair techniques for damaged high rise buildings. The book will help upcoming structural design engineers learn the computer aided analysis and design of real existing high rise buildings ...

  1. The Relationship of Children Connectivity and Physical Activities with Satisfaction of Open Spaces in High Rise Apartments in Tehran

    Directory of Open Access Journals (Sweden)

    Ali Sharghi

    2014-07-01

    Full Text Available Increase of urbanization has pressure on the urban children's lives and physical activities. While in designing of residential apartments’ open spaces, there is little attention to the children. The children, who live in the high-rise apartments found to have less physical activities. However, supposedly, children need to engage in the physical activity in the outdoor areas as WHO recommend that children take part in at least one hour of moderate physical activity in every day. This paper firstly, reviews different researches in this area. Then, it attempts to find children’s satisfaction regarding connectivity to open spaces as a dependent variable and their preferred activities, perceived safety, and familiarity about connectivity to open spaces as independent variables. The method of study is a semi-interview survey with 80 children between 6 and 12 years old (primary school ages in two cases in Tehran. The result of this research shows that children satisfaction from open space has an effect on their outdoor activities. Therefore, the designers should be considering children physical activities needs in open spaces.

  2. Measure Guideline: Ventilation Guidance for Residential High-Performance New Construction - Multifamily

    Energy Technology Data Exchange (ETDEWEB)

    Lstiburek, Joseph [Building Science Corp., Westford, MA (United States)

    2017-01-01

    The measure guideline provides ventilation guidance for residential high performance multifamily construction that incorporates the requirements of the ASHRAE 62.2 ventilation and indoor air quality standard. The measure guideline focus is on the decision criteria for weighing cost and performance of various ventilation systems. The measure guideline is intended for contractors, builders, developers, designers and building code officials. The guide may also be helpful to building owners wishing to learn more about ventilation strategies available for their buildings. The measure guideline includes specific design and installation instructions for the most cost effective and performance effective solutions for ventilation in multifamily units that satisfies the requirements of ASHRAE 62.2-2016.

  3. Construction technology of high-rise pile cap foundation of offshore wind power in Taiwan Strait

    Science.gov (United States)

    Li, C. Y.; Chi, Y.; Sun, X. Q.; Han, Y. P.; Chen, X.; Zhao, L. C.; Zhang, H.

    2017-11-01

    Offshore wind farms promise to become an important source of energy in the near future. The high-rise pile cap foundation is one of the typical foundation types for offshore wind turbine. This paper introduces the structural characteristics and construction technology of high-rise pile cap foundation, aiming at the characteristics of the sea area of Taiwan Strait and combining with engineering examples. The construction technology of high-rise pile cap foundation is expounded emphatically from the manufacture and transportation of steel pipe piles, pile foundation construction and bearing platform construction. Compared with the traditional construction technology, the construction technologies used in this project are safer and more reliable. The construction period of piles cap foundation is shortened by 10 ∼ 48 days. The construction technology provides reference for offshore wind power foundation construction.

  4. Influence of placement and height of high-rise buildings on wind pressure distribution and natural ventilation of low- and medium-rise buildings

    Czech Academy of Sciences Publication Activity Database

    Kuznetsov, Sergeii; Butova, A.; Pospíšil, Stanislav

    2016-01-01

    Roč. 15, 3/4 (2016), s. 253-266 ISSN 1473-3315 R&D Projects: GA ČR(CZ) GA14-12892S; GA MŠk(CZ) LO1219 Keywords : natural ventilation * high-rise buildings * low- and medium-rise buildings * wind pressure coefficient * wind tunnel tests Subject RIV: JM - Building Engineering Impact factor: 0.391, year: 2016 http://www.tandfonline.com/doi/full/10.1080/14733315.2016.1214396

  5. Computational Simulation of Smoke Temperature Diffusion in High-rise Buildings Fires

    OpenAIRE

    Ru Zhou; , Wei Zhang; Dong Zhao

    2013-01-01

    In order to control the smoke diffusing and prevent the damage to the people, the smoke temperature was researched. In high-rise building fires, the most immediate threat to passengers’ life is not the direct exposure to fire but the smoke inhalation because it contains hot air and toxic gases, so it has positive meaning to find the rules of the smoke temperature distribution. The variable rule of smoke temperature field distribution in passages of high-rise building was the foundation of fir...

  6. Hydraulic Control Method for Heating Systems of High-Rise Buildings

    Science.gov (United States)

    Makarov, D.; Chernenkov, V.; Likhachev, I.

    2017-11-01

    The following article reflects the ideas of possibility to increase energy efficiency of heating systems in high-rise buildings. The article also includes the principle ways of high-rise building heating systems operation as well as traditional engineering decisions aimed at the elimination of the increased pressure effect in heaters. The main disadvantages of such decisions are also presented for the reader. Moreover, the article offers the way of operation for the above-mentioned systems together with the equipment that implements this operation. An economic impact from such energy-saving technology application has been also evaluated.

  7. Uptilted Macros as an Outdoor Solution for Indoor Users in High Rise Buildings

    DEFF Research Database (Denmark)

    Sanchez, Maria Laura Luque; Vejlgaard, Benny; Mogensen, Preben

    2015-01-01

    With an expected broadband traffic volume growth of 1000x in the coming years, the need to provide coverage and capacity to the high rise buildings scenarios becomes a challenge for operators. Due to the difficulties in deploying their networks inside buildings, an outdoor alternative is needed....... This paper investigates the usage of Long Term Evolution-Advanced (LTEA) uptilted macros pointing to the upper floors, as an outdoor solution to provide coverage and capacity to high rise buildings. This solution, in combination with the existing downtilted macro and street level micro networks, is able...

  8. Prefabricated high-rise resources. Competition for energetic modernization of industrially prefabricated high-rise buildings; Ressource Plattenbau. Wettbewerb zur energetischen Sanierung von Grosswohnsiedlungen

    Energy Technology Data Exchange (ETDEWEB)

    Kopf, Iris

    2009-07-01

    About 7.5 percent of all apartments in Germany are in prefabricated high-rise buildings constructed between the 1950ies and the 1980ies. Often, these have become trouble hotspots, and most of them also have a poor energy balance. In January 2009, the German Federal Government invited a competition for energetic modernization of this type of buildings (''Energetische Sanierung von Grosswohnsiedlungen auf der Grundlage von integrierten Stadteilentwicklungskonzepten''). The winners received their awards on 15 July 2009. (orig.)

  9. Using wind turbines in high-rise buildings in the development of ...

    African Journals Online (AJOL)

    Since the shallow waters of the Persian Gulf and coasts of this region are great places for installing wind turbines, in this regard, this study by studying documents and field studies to evaluate how the use of wind energy in high-rise buildings of these areas in order to maintain the environmental and energy efficiency leads ...

  10. Effect of turning frequency and season on composting materials from swine high-rise facilities

    Science.gov (United States)

    Composting of swine manure has several advantages, liquid slurries are converted to solid, the total volume of material is reduced and the stabilized product is more easily transported off-site. Despite this, swine waste is generally stored, treated and applied in its liquid form. The high-rise fini...

  11. Wind-tunnel investigations of pressure distribution over high-rise buildings

    CSIR Research Space (South Africa)

    Cwik, M

    2013-09-01

    Full Text Available This paper deals with the wind-tunnel investigations of high-rise buildings. In the first part, an overview of the developments in model testing, as well as the future trends, have been discussed. Particular emphasis has been placed on methods...

  12. Field monitoring of column shortenings in a high-rise building during construction.

    Science.gov (United States)

    Choi, Se Woon; Kim, Yousok; Kim, Jong Moon; Park, Hyo Seon

    2013-10-24

    The automatic monitoring of shortenings of vertical members in high-rise buildings under construction is a challenging issue in the high-rise building construction field. In this study, a practical system for monitoring column shortening in a high-rise building under construction is presented. The proposed monitoring system comprises the following components: (1) a wireless sensing system and (2) the corresponding monitoring software. The wireless sensing system comprises the sensors and energy-efficient wireless sensing units (sensor nodes, master nodes, and repeater nodes), which automate the processes for measuring the strains of vertical members and transmitting the measured data to the remote server. The monitoring software enables construction administrators to monitor real-time data collected by the server via an Internet connection. The proposed monitoring system is applied to actual 66-floor and 72-floor high-rise buildings under construction. The system enables automatic and real-time measurements of the shortening of vertical members, which can result in more precise construction.

  13. Methodology for estimating human perception to tremors in high-rise buildings

    Science.gov (United States)

    Du, Wenqi; Goh, Key Seng; Pan, Tso-Chien

    2017-07-01

    Human perception to tremors during earthquakes in high-rise buildings is usually associated with psychological discomfort such as fear and anxiety. This paper presents a methodology for estimating the level of perception to tremors for occupants living in high-rise buildings subjected to ground motion excitations. Unlike other approaches based on empirical or historical data, the proposed methodology performs a regression analysis using the analytical results of two generic models of 15 and 30 stories. The recorded ground motions in Singapore are collected and modified for structural response analyses. Simple predictive models are then developed to estimate the perception level to tremors based on a proposed ground motion intensity parameter—the average response spectrum intensity in the period range between 0.1 and 2.0 s. These models can be used to predict the percentage of occupants in high-rise buildings who may perceive the tremors at a given ground motion intensity. Furthermore, the models are validated with two recent tremor events reportedly felt in Singapore. It is found that the estimated results match reasonably well with the reports in the local newspapers and from the authorities. The proposed methodology is applicable to urban regions where people living in high-rise buildings might feel tremors during earthquakes.

  14. Is the sky the limit? High-rise buildings and office rents

    NARCIS (Netherlands)

    Koster, H.R.A.; van Ommeren, J.N.; Rietveld, P.

    2014-01-01

    Modern central business districts are characterized by high-rise office buildings, but their presence cannot be explained by standard urban economic models only. We aim to explore the impact of other forces that explain the presence of tall buildings, by examining the existence of a building height

  15. APPLICATION OF RIT PILES IN FOUNDATIONS OF HIGH-RISE BUILDINGS

    Directory of Open Access Journals (Sweden)

    Kubetskiy Valeriy Leonidovich

    2012-07-01

    On the basis of the analysis of the monitoring results, the technology and tests of PIT piles, a conclusion can be made that PIT piles, that have a diameter of 320 mm, assure the pre-set reliability of high-rise buildings in complex engineering and geological environments.

  16. Evaluation of Indoor Radio Deployment Options in High-Rise Building

    DEFF Research Database (Denmark)

    Nguyen, Huan Cong; Wigard, Jeroen; Kovacs, Istvan

    2017-01-01

    In this paper we set out to analyze the indoor capacity under a realistic high-rise building scenario. The study takes into consideration the number of indoor cells deployed per floor, different inter-site distances (ISDs), transmit power settings and outdoor macro interference levels. The outcome...

  17. Thin-Walled CFST Columns for Enhancing Seismic Collapse Performance of High-Rise Steel Frames

    Directory of Open Access Journals (Sweden)

    Yongtao Bai

    2017-01-01

    Full Text Available This paper numerically studied the collapse capacity of high-rise steel moment-resisting frames (SMRFs using various width-to-thickness members subjected to successive earthquakes. It was found that the long-period component of earthquakes obviously correlates with the first-mode period of high-rises controlled by the total number of stories. A higher building tends to produce more significant component deterioration to enlarge the maximum story drift angle at lower stories. The width-to-thickness ratio of beam and column components overtly affects the collapse capacity when the plastic deformation extensively develops. The ratio of residual to maximum story drift angle is significantly sensitive to the collapse capacity of various building models. A thin-walled concrete filled steel tubular (CFST column is proposed as one efficient alternative to enhance the overall stiffness and deformation capacity of the high-rise SMRFs with fragile collapse performance. With the equivalent flexural stiffness, CFST-MRF buildings with thin-walled members demonstrate higher capacity to avoid collapse, and the greater collapse margin indicates that CFST-MRFs are a reasonable system for high-rises in seismic prone regions.

  18. INFORMATION MODELING OF LIFE CYCLE OF HIGH-RISE CONSTRUCTION PROJECTS

    Directory of Open Access Journals (Sweden)

    Gusakova Elena Aleksandrovna

    2018-02-01

    Full Text Available To date, many years’ experience in the construction and operation of high-rise buildings has been accumulated. Its analysis reveals not only the engineering and organizational-technological specifics of such projects, but also systemic gaps in the field of management. In the implementation of large-scale and unique projects for high-rise buildings, the problems and tasks of improving approaches to managing the full life cycle of projects and methods, which will improve their competitiveness, become topical. The systems being used have largely exhausted their resource efficiency, which is associated with automation of traditional “inherited” processes and management structures, as well as development of IT-systems focused on digitalization of the activities of construction company, rather than the project. To solve these problems, it is proposed to carry out: reengineering of the schemes of information interaction between the project’s participants; formation of integrated digital environment for the life cycle of the project; development of systems for integrating data management and project management. Subject: problems, approaches and methods of digitalization of project’s life cycle management in relation to the specifics and features of high-rise buildings. Research objectives: substantiation of the most perspective approaches and methods of information modeling of high-rise construction as the basis for managing the full life cycle of the given project. Materials and methods: the experience of digitalization of design, construction, operation and development of high-rise buildings, presented in specialized literature, is analyzed. The methods for integrating information models of various stages of project’s life cycle and for information interaction of project’s participants are considered. Results: the concept of forming a single digital environment for the project is proposed, taking into account the features of the life

  19. High-rise build renovation - Colouring a high-rise building's facade; Renovation des Hochhauses Schoppi Spreitenbach. Farbigkeit einer Hochhausfassade

    Energy Technology Data Exchange (ETDEWEB)

    Enkerli, W.

    2008-07-01

    This illustrated article takes a look at the renovation of the 70-metres high, high-rise apartment building that forms an integral part of a large shopping centre in Spreitenbach, Switzerland. The buildings and their infrastructure, realised in 1970, were in need of renovation. The facade elements no longer met energy requirements and the shopping mall was to be extended to meet modern shopping needs. The article deals with the technical and aesthetic requirements placed on the facades. The colour concept for the venetian blinds integrated into the windows, which includes the use of 20 different shades of colour, is described. A total of 3,200 blinds are fitted. The removal of the old window elements and the fitting of the new facade elements is described and discussed.

  20. Residential High-Speed Internet Among Those Likely to Benefit From an Online Health Insurance Marketplace

    Directory of Open Access Journals (Sweden)

    Michel H. Boudreaux PhD

    2016-01-01

    Full Text Available Using data from the 2013 American Community Survey, we found that 24.3 million people (about 1 in 4 who were either eligible for Medicaid/Children’s Health Inusrance Program (CHIP or appeared likely to shop for Qualified Health Plan (QHP lacked residential high-speed Internet. Specifically, 28.6% or 18.9 million people eligible for Medicaid/CHIP and 17.1% or 5.5 million people who appeared likely to shop for a QHP did not have high-speed Internet in the home. For both the Medicaid/CHIP eligible and those likely to shop for a QHP, the proportion of people living in households without Internet varied substantially by race, geography, and other socio-demographic characteristics.

  1. Large-eddy simulation of vortex streets and dispersion behind high-rise buildings

    Science.gov (United States)

    Han, Beom-Soon; Park, Seung-Bu; Baik, Jong-Jin

    2015-11-01

    Understanding flow and dispersion in densely built-up urban areas is one of the important problems in the field of urban fluid mechanics. Nowadays, sophisticated numerical models and high-resolution urban morphology data enable us to study detailed flow structures in real urban areas. Simulations with high-resolution urban morphology data show very complex flow structures in several studies. Here, we examine turbulent flow patterns and associated pollutant dispersion near and, particularly, behind high-rise buildings using the parallelized large-eddy simulation model (PALM) and high-resolution urban morphology data. The study area selected is a highly built-up area of Seoul, South Korea. It is shown that turbulent wakes are produced behind high-rise buildings and vortex streets appear in the places where turbulent wakes occur. The vortex street seems to be related to strong updrafts and ejections that appear downwind of high-rise buildings. The vortex street is found to affect pollutant dispersion. Various factors that influence the evolution and structure of vortex streets will be presented and discussed along with involved dispersion mechanisms.

  2. Managing the Rising Costs and High Drug Expenditures in Critical Care Pharmacy Practice.

    Science.gov (United States)

    Flannery, Alexander H; Pandya, Komal; Laine, Melanie E; Almeter, Philip J; Flynn, Jeremy D

    2017-01-01

    Pharmaceutical costs for patients in the intensive care unit (ICU) constitute a large portion of hospital drug budgets. Unfortunately, prices for medications commonly used in the ICU are on the rise for a variety of reasons. In particular, the U.S. Food and Drug Administration's Unapproved Drugs Initiative, generic manufacturers cornering the marketplace, drug shortages, and regulatory device changes are major drivers of pharmaceutical price escalation affecting costs in the ICU. Furthermore, traditional high acquisition cost items still pose challenges to controlling costs. To offer strategies to mitigate the rising costs of pharmaceuticals in the ICU setting, we searched the PubMed/Medline and International Pharmaceutical Abstracts databases and other related sources to identify published cost-saving protocols concerning specific medications that are affected by rising prices or have traditional high acquisition costs. In the absence of specific protocols, we offer possible cost-saving initiatives based on published literature regarding specific agents or based on our own diverse set of experiences. Finally, we review suggested clinical and operational activities at an institutional level to address these rising drug costs in the ICU setting. © 2016 Pharmacotherapy Publications, Inc.

  3. Numerical Study on Mass Transfer of a Vapor Bubble Rising in Very High Viscous Fluid

    Directory of Open Access Journals (Sweden)

    T. Kunugi

    2014-09-01

    Full Text Available This study focused on a bubble rising behavior in a molten glass because it is important to improve the efficiency of removal of bubbles from the molten glass. On the other hand, it is expected that some gas species which exists in a bubble are transferred into the molten glass through the bubble interface, i.e., the mass transfer, subsequently, it may cause a bubble contraction in the molten glass. In this paper, in order to understand the bubble rising behavior with its contraction caused by the mass transfer through the bubble interface in the very high viscous fluid such as the molten glass, a bubble contraction model has been developed. The direct numerical simulations based on the MARS (Multi-interface Advection and Reconstruction Solver coupled with the mass transfer equation and the bubble contraction model regarding the mass transfer from the rising bubble in very high viscous fluid have been performed. Here, the working fluids were water vapor as the gas species and the molten glass as the very high viscous fluid. Also, the jump conditions at the bubble interface for the mass transfer were examined. Furthermore, the influence of the bubble contraction for the bubble rising compared to that in the water as a normal viscous fluid was investigated. From the result of the numerical simulations, it was found that the bubble rising behavior was strongly affected not only by the viscosity of the working fluid but also by the bubble contraction due to the mass transfer through the bubble interface.

  4. Natural ventilation in high-rise buildings with double facades, saving or waste of energy

    Energy Technology Data Exchange (ETDEWEB)

    Pasquay, T. [Schmidt Reuter Partner , Engineering Co., Research and Development, Koln (Germany)

    2004-04-01

    Double facades are built to allow natural ventilation in high-rise buildings and buildings with high outside noise levels. To evaluate the energetic performance, three buildings with double facades were monitored for at least a year (Siemens building in Dortmund, Victoria Insurance Company in Dusseldorf and RWE Tower in Essen). In one building all the air conditioning facilities had been removed and the facade replaced by a double facade, one building had cooling equipment without mechanical ventilation (concrete core tempered ceiling) and one building had cooling equipment combined with mechanical ventilation. The results document the indoor climate, the boundary conditions for further planning and the possibilities for high-rise buildings with no or only limited cooling facilities. The research was carried out at the University of Dortmund and founded by the state of Nordrhein-Westfahlen (AG-Solar). (author)

  5. Natural ventilation in high-rise buildings with double facades, saving or waste of energy?

    Energy Technology Data Exchange (ETDEWEB)

    Pasquay, T. [Schmidt Reuter Partner, Engineering Company, Research and Development, Koeln (Germany)

    2004-07-01

    Double facades are built to allow natural ventilation in high-rise buildings and buildings with high outside noise levels. To evaluate the energetic performance, three buildings with double facades were monitored for at least one year (Siemens building in Dortmund, Victoria Insurance Company in Duesseldorf and RWE Tower in Essen, all in Germany). In one building all the air conditioning facilities had been removed and the facade replaced by a double facade, one building had cooling equipment without mechanical ventilation (concrete core tempered ceiling) and one building had cooling equipment combined with mechanical ventilation. The results document the indoor climate, the boundary conditions for further planning and the possibilities for high-rise buildings with no or only limited cooling facilities. The research was carried out at the University of Dortmund and founded by the state of Nordrhein-Westfahlen (AG-Solar). (author)

  6. Residential radon exposure and esophageal cancer. An ecological study from an area with high indoor radon concentration (Galicia, Spain).

    Science.gov (United States)

    Ruano-Ravina, Alberto; Aragonés, Nuria; Pérez-Ríos, Mónica; López-Abente, Gonzalo; Barros-Dios, Juan M

    2014-04-01

    To analyze the correlation between municipal esophageal cancer relative risk and municipal residential radon concentration in a high radon emission Spanish area. We performed an ecological study at municipal level in Galicia, Spain. For each municipality we estimated the median radon concentration and the relative risk (RR) for esophageal cancer mortality for males and females. The relative risk was calculated using a Bayesian approach. Homes with data on radon concentration were selected through stratified random sampling. To be included, each municipality had to have at least five radon measurements. We obtained Spearman's correlations for median residential radon concentration and esophageal cancer mortality RR for males and females, separately. We included 129 municipalities, covering the 79% of Galician population. 14% of municipalities had radon concentrations above the United States Environmental Protection Agency (USEPA) action level. We found a statistically significant correlation among residential radon and esophageal cancer mortality RR for males (p radon measurements the correlation pattern remained. This is the first study analyzing the association between residential radon and esophageal cancer. The results suggesting a possible effect of residential radon on esophageal cancer mortality should be explored through more robust epidemiological designs such as case-control studies.

  7. Wind Resource Assessment for High-Rise BIWT Using RS-NWP-CFD

    Directory of Open Access Journals (Sweden)

    Hyun-Goo Kim

    2016-12-01

    Full Text Available In this paper, a new wind resource assessment procedure for building-integrated wind turbines (BIWTs is proposed. The objective is to integrate wind turbines at a 555 m high-rise building to be constructed at the center of Seoul, Korea. Wind resource assessment at a high altitude was performed using ground-based remote sensing (RS; numerical weather prediction (NWP modeling that includes an urban canopy model was evaluated using the remote sensing measurements. Given the high correlation between the model and the measurements, we use the model to produce a long-term wind climate by correlating the model results with the measurements for the short period of the campaign. The wind flow over the high-rise building was simulated using computational fluid dynamics (CFD. The wind resource in Seoul—one of the metropolitan cities located inland and populated by a large number of skyscrapers—was very poor, which results in a wind turbine capacity factor of only 7%. A new standard procedure combining RS, NWP, and CFD is proposed for feasibility studies on high-rise BIWTs in the future.

  8. Organisational and environmental characteristics of residential aged care units providing highly person-centred care: a cross sectional study.

    Science.gov (United States)

    Sjögren, Karin; Lindkvist, Marie; Sandman, Per-Olof; Zingmark, Karin; Edvardsson, David

    2017-01-01

    Few studies have empirically investigated factors that define residential aged care units that are perceived as being highly person-centred. The purpose of this study was to explore factors characterising residential aged care units perceived as being highly person-centred, with a focus on organisational and environmental variables, as well as residents' and staff' characteristics. A cross-sectional design was used. Residents (n = 1460) and staff (n = 1213) data from 151 residential care units were collected, as well as data relating to characteristics of the organisation and environment, and data measuring degree of person-centred care. Participating staff provided self-reported data and conducted proxy ratings on residents. Descriptive and comparative statistics, independent samples t-test, Chi2 test, Eta Squared and Phi coefficient were used to analyse data. Highly person-centred residential aged care units were characterized by having a shared philosophy of care, a satisfactory leadership, interdisciplinary collaboration and social support from colleagues and leaders, a dementia-friendly physical environment, staff having time to spend with residents, and a smaller unit size. Residential aged care units with higher levels of person-centred care had a higher proportion of staff with continuing education in dementia care, and a higher proportion of staff receiving regular supervision, compared to units with lower levels of person-centred care. It is important to target organisational and environmental factors, such as a shared philosophy of care, staff use of time, the physical environment, interdisciplinary support, and support from leaders and colleagues, to improve person-centred care in residential care units. Managers and leaders seeking to facilitate person-centred care in daily practice need to consider their own role in supporting, encouraging, and supervising staff.

  9. High Rise Building: The Mega Sculpture Made Of Steel, Concrete and Glass

    Science.gov (United States)

    Stefańska, Alicja; Załuski, Daniel

    2017-10-01

    High rise building has transformed from providing not only the expansion of floor space but functioning as mega sculpture in the city. The shift away from economic efficiency driven need is only expected to grow in the future. Based on literature studies; after analysing planning documents and case studies, it was examined whether the presumption that gaining the maximum amount of usable area is the only driving factor; or if the need for the creation of an image for the city provided a supplementary reason. The results showed that forming high rise buildings as three-dimensional sculptures is influenced not only by aesthetics, but also marketing. Visual distinction in the city skyline is economically beneficial for investors gaining not only functionality but art, enriching the cultural landscape. Organizing architectural competitions, public debates and following the latest art trends is therefore possible due to large budgets of such projects.

  10. Open and closed shear-walls in high-rise structural systems: Static and dynamic analysis

    Science.gov (United States)

    Carpinteri, Alberto; Lacidogna, Giuseppe; Nitti, Giuseppe

    2016-06-01

    In the present paper, a General Algorithm is applied to the analysis of high-rise structures. This algorithm is to be used as a calculation tool in preliminary design; it allows to define the interaction between closed and open, straight or curved shear-walls, and the forces exchanged in structures subject to mainly horizontal loads. The analysis can be performed in both static and dynamic regimes, the mode shapes and the natural frequencies being assessed. This general formulation allows analyses of high-rise structures by taking into account the torsional rigidity and the warping deformations of the elements composing the building without gross simplifications. In thisway it is possible to model the structure as a single equivalent cantilever, thus minimising the degrees of freedom of the system, and consequently the calculation time. Finally, potentials of the method proposed are demonstrated by a numerical example which emphasizes the link between global displacements and stresses in the elements composing the structure.

  11. An energy harvesting system utilizing wind pressure fluctuations on high-rise building envelope

    Science.gov (United States)

    Park, Jae-Chan; Kim, In-Ho; Jang, Seon-Jun; Jung, Hyung-Jo

    2017-04-01

    In this paper, the new energy harvesting system is proposed by using wind pressure fluctuations which are one of existing energy sources that were not taken into consideration around high-rise buildings. The proposed system carries out the role of building envelope also. This research is divided in two parts. At first, Computational Fluid Dynamics (CFD) and wind tunnel experiments are performed for investigating the wind pressure that occur around the high-rise building. Secondly, based on the result of wind pressure analysis, the optimal mechanism is devised and the prototype of the energy harvesting system is designed to verify the possibility of utilization of wind pressure fluctuations through the small wind tunnel experiment, harmonic excitation experiment and numerical analysis. As a result, the performance of proposed energy harvesting system is numerically and experimentally validated.

  12. Behavior of 222Rn and its progeny in high-rise buildings.

    Science.gov (United States)

    Leung, J K; Tso, M Y; Ho, C W

    1998-09-01

    Unlike detached or semi-detached houses, the main source of indoor radon in high-rise buildings is the building material. Radon released from the building material will be removed by ventilation, either forced or natural, so that its concentration, its progeny's concentration, and the equilibrium between the two will be different for different types of buildings and environmental factors. A number of surveys were carried out in buildings throughout the territory to look at the seasonal variation of indoor 222Rn levels; the dependence of indoor 222Rn concentration on the living environment; the indoor gamma dose rate and its relation to indoor 222Rn concentration; and the dependence of 222Rn progeny concentration and equilibrium factor on the environment in high-rise buildings.

  13. The activity of radon daughters in high-rise buildings and the influence of soil emanation

    Energy Technology Data Exchange (ETDEWEB)

    Abu-Jarad, F. (Univ. of Petroleum and Minerals, Dhahran, Saudi Arabia); Fremlin, J.H.

    1982-01-01

    Forty measurements are reported in similar rooms in two high-rise buildings. The geometrical means for the concentration of radon daughters including and excluding the basement results, respectively, were 0.90 and 1.00mWL, which is less than the quoted mean 2.0 mWL for 65 measurements in typical houses in the same city. The frequency distribution of these measurements shows a log-normal distribution. The concentrations did not depend on the distance from ground level but may depend on the ventilation rate of the room examined. The correlation between the concentration of radon daughters in WL in rooms above the first floor in the two high-rise buildngs with the inverse of their ventilation rate were 0.73 and 0.67, respectively.

  14. Behavior of {sup 222}Rn and its progeny in high-rise buildings

    Energy Technology Data Exchange (ETDEWEB)

    Leung, J.K.C.; Tso, M.Y.W.; Ho, C.W. [Univ. of Hong Kong (Hong Kong). Radioisotope Unit

    1998-09-01

    Unlike detached or semi-detached houses, the main source of indoor radon in high-rise buildings is the building material. Radon released from the building material will be removed by ventilation, either forced or natural, so that its concentration, its progeny`s concentration, and the equilibrium between the two will be different for different types of buildings and environmental factors. A number of surveys were carried out in buildings throughout the territory to look at the seasonal variation of indoor {sup 222}Rn levels; the dependence of indoor {sup 222}Rn concentration on the living environment; the indoor gamma dose rate and its relation to indoor {sup 222}Rn concentration; and the dependence of {sup 222}Rn progeny concentration and equilibrium factor on the environment in high-rise buildings.

  15. Activity of radon daughters in high-rise buildings and the influence of soil emanation

    Energy Technology Data Exchange (ETDEWEB)

    Abu-Jarad, F. (University of Petroleum and Minerals, Dhahran, Saudi-Arabia. Dept. of Physics); Fremlin, J.H. (Birmingham Univ. (UK). Dept. of Physics)

    1982-01-01

    Forty measurements are reported in similar rooms in two high-rise buildings. The geometrical means for the concentration of radon daughters including and excluding the basement results, respectively, were 0.90 and 1.00 mWL, which is less than the quoted mean 2.0 mWL for 65 measurements in typical houses in the same city. The frequency distribution of these measurements shows a log-normal distribution. The concentrations did not depend on the distance from ground level but may depend on the ventilation rate of the room examined. The correlation between the concentration of radon daughters in WL in rooms above the first floor in the two high-rise buildings with the inverse of their ventilation rate were 0.73 and 0.67, respectively.

  16. The Reuse of Greywater Recycling For High Rise Buildings in Kuwait Country

    OpenAIRE

    Ahmed Ibrahim Abd Alaziz; Naji Fahad Al-Saqer

    2014-01-01

    The domestic grey water recycling and reuse in high rise buildings has been discussed and detailed. It is estimated that the usable domestic grey water resource could amount from to 35% to 39% of the total domestic demand. A summary of worldwide review of recycling and reuse of grey water is reported. In many cases, light grey water from bathroom sinks, baths and showers can be directly reused in garden irrigation. Dark grey water from laundry, dishwashers and, in some instanc...

  17. Check the comfort of occupants in high rise building using CFD

    OpenAIRE

    Mohamed I. Farouk

    2016-01-01

    The influence of wind on structures is a complex subject. Bending moments, normal forces, torsion moments, stresses on cladding, comfort of the pedestrians around new building, the impact of new building on existing buildings, internal pressures and vibrations are the main effects of the wind on the structures. Vibration of the structures is one of the major effects of wind especially on bridges and high rise buildings. It could lead to major displacements, accelerations and resulting forces....

  18. INNOVATIVE SOLUTIONS FOR BUILDING ENVELOPES OF BIOCLIMATICAL HIGH-RISE BUILDINGS

    OpenAIRE

    Generalova, Elena; Generalov, Victor; Kuznetsova, Anna

    2017-01-01

    The paper examines innovative and promising trends in in the design of high-rise buildings that challenge traditional typologies and are adapted for specific climatic conditions. The purpose of the study is to investigate modern methods of designing building envelopes for bioclimatic skyscrapers taking into account heat impact of climate on the thermal balance of buildings. The research methodology is based on a systematic analysis of advanced world experience in constructing innovative b...

  19. Luminescent rise times of inorganic phosphors excited by high intensity ultraviolet light.

    Science.gov (United States)

    Anderson, R J; Ricchio, S G

    1973-11-01

    The relative delay between excitation and luminescence was measured for a number of common inorganic phosphors using short, high intensity excitation pulses. The delays were found to be much shorter than anticipated; on the basis of low intensity pulsed luminescence measurements and were found to be extremely intensity-dependent. Both the luminescence rise and decay times were found to be intensitydependent as well, with the luminescence pulse waveform tending to approach the exciting pulse at the higher excitation intensities.

  20. Effects of Bracing of High-Rise Buildings upon their Static and Dynamic Behavior

    Directory of Open Access Journals (Sweden)

    Ivánková Oľga

    2014-05-01

    Full Text Available The paper describes effects of bracing of high-rise buildings upon their static and dynamic behaviour. In static and dynamic analyses, values of displacement for 4 different variants of stiffening elements distribution were calculated. The calculations were made for building both fixed into the ground and rested on elastic supports. The building was modelled as a 3D variant using Finite Element Method (FEM in program Scia Engineer.

  1. On Roof Geometry for Urban Wind Energy Exploitation in High-Rise Buildings

    OpenAIRE

    Francisco Toja-Silva; Carlos Peralta; Oscar Lopez-Garcia; Jorge Navarro; Ignacio Cruz

    2015-01-01

    The European program HORIZON2020 aims to have 20% of electricity produced by renewable sources. The building sector represents 40% of the European Union energy consumption. Reducing energy consumption in buildings is therefore a priority for energy efficiency. The present investigation explores the most adequate roof shapes compatible with the placement of different types of small wind energy generators on high-rise buildings for urban wind energy exploitation. The wind flow around traditiona...

  2. Robustness Evaluation of Elastoplastic Base-Isolated High-Rise Buildings Subjected to Critical Double Impulse

    Directory of Open Access Journals (Sweden)

    Kohei Fujita

    2017-05-01

    Full Text Available A new method of robustness evaluation is proposed for an elastoplastic base-isolated high-rise building considering simultaneous uncertainties of structural parameters. Since it is difficult to evaluate the robustness of elastoplastic structures due to heavy computational load on the time-history response analysis including elastoplastic response, a double impulse input is used to provide a closed-form solution of the critical response of a single-degree-of-freedom (SDOF elastic–perfectly plastic structure under a near-field ground motion. Introducing an equivalent elastoplastic SDOF model of a base-isolated high-rise building, the worst combination of uncertain structural parameters, i.e., the stiffness and yield deformation at the base-isolation story and the stiffness of the superstructure, can be derived which leads to the upper bound of the critical elastoplastic response. It is shown that, by using the derived upper bound of the critical response, the robustness function, a measure of the robustness, of elastoplastic structures can be evaluated efficiently. In numerical examples, the robustness of a 30-story base-isolated high-rise building is compared with those of other models with different yield deformations at the base-isolation story to find a preferable design with larger robustness.

  3. Seismic Response of Base-Isolated High-Rise Buildings under Fully Nonstationary Excitation

    Directory of Open Access Journals (Sweden)

    C. F. Ma

    2014-01-01

    Full Text Available Stochastic seismic responses of base-isolated high-rise buildings subjected to fully nonstationary earthquake ground motion are computed by combining the pseudoexcitation and the equivalent linearization methods, and the accuracy of results obtained by the pseudoexcitation method is verified by the Monte Carlo method. The superstructure of a base-isolated high-rise building is represented by a finite element model and a shear-type multi-degree of freedom model, respectively. The influence of the model type and the number of the modes of the superstructure participating in the computation of the dynamic responses of the isolated system has been investigated. The results of a 20-storey, 3D-frame with height to width ratio of 4 show that storey drifts and absolute accelerations of the superstructure for such a high-rise building will be substantially underestimated if the shear-type multi-degree of freedom model is employed or the higher modes of the superstructure are neglected; however, this has nearly no influence on the drift of the base slab.

  4. The influence of high-rise buildings on urban stormwater response - a laboratory physical model

    Science.gov (United States)

    Isidoro, J. M. G. P.; Rocheta, V. L. S.; de Lima, J. L. M. P.

    2009-04-01

    One consequence of the tendency for population agglomeration in large urban centres is the construction of more high-rise buildings, which both allows for a better use of the space available and reduces the construction cost per unit of area. The influence of high-rise buildings on the response of urban drainage systems to wind-driven rain is currently not well known. The importance of the combined action of wind and rain has been recognized by a number of investigators. Some investigators have also considered the movement of rainfall over basins, particularly upstream or downstream movement. This study, based on the physical modelling in the laboratory of the rainfall-runoff process in areas with a range of densities of high-rise buildings (typical in downtown areas), aims to help to improve our knowledge in this specific domain. Laboratory tests were carried out to simulate the response of a drainage system to static and moving rainfall in diverse directions, with varied building density, and considering the existence or non-existence of wind. A physical model (1:100 scale) was built in the laboratory, representing an urban area of 40 000 m2, with high rise buildings (rectangular three dimensional elements representing medium to large buildings of approximately 20 storeys). A rain simulator (full-cone nozzle) was installed on a structure that was electrically driven along a rail to simulate the rain cell movement. Preliminary laboratory experiments illustrate the influence of high density construction on stormwater's flow. Results will also analyse the influence of storm movement and wind which affects the spatial and temporal distribution of rainfall at ground level. The laboratory experiments described in this work show that the construction density, spatial and temporal distributions of rainfall, wind and storm movement have a marked influence on the processes of overland flow. The results indicate considerable differences in runoff volumes and peaks, and

  5. Energy Savings Potential and Opportunities for High-Efficiency Electric Motors in Residential and Commercial Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Sutherland, Timothy [Navigant Consulting, Inc., Burlington, MA (United States); Reis, Callie [Navigant Consulting, Inc., Burlington, MA (United States)

    2013-12-04

    This report describes the current state of motor technology and estimates opportunities for energy savings through application of more advanced technologies in a variety of residential and commercial end uses. The objectives of this report were to characterize the state and type of motor technologies used in residential and commercial appliances and equipment and to identify opportunities to reduce the energy consumption of electric motor-driven systems in the residential and commercial sectors through the use of advanced motor technologies. After analyzing the technical savings potential offered by motor upgrades and variable speed technologies, recommended actions are presented.

  6. A Comparative Study of Design Strategies for Energy Efficiency in 6 High-Rise Buildings in Two Different Climates

    NARCIS (Netherlands)

    Raji, B.; Tenpierik, M.J.; Van den Dobbelsteen, A.A.J.F.

    2014-01-01

    Due to the ever growing trend of urbanization and population growth, the construction of high-rise buildings is inevitable and will also continue at an ever increasing pace. However, typical high-rise buildings (the traditional template of a rectilinear, air-conditioned box) are not energy efficient

  7. Breakdown in helium in high-voltage open discharge with subnanosecond current front rise

    Energy Technology Data Exchange (ETDEWEB)

    Schweigert, I. V., E-mail: ischweig@itam.nsc.ru; Alexandrov, A. L. [Russian Academy of Sciences, Khristianovich Institute of Theoretical and Applied Mechanics, Siberian Branch (Russian Federation); Bokhan, P. A.; Zakrevskiy, Dm. E. [Russian Academy of Sciences, Rzhanov Institute of Semiconductors Physics, Siberian Branch (Russian Federation)

    2016-07-15

    Investigations of high-voltage open discharge in helium have shown a possibility of generation of current pulses with subnanosecond front rise, due to ultra-fast breakdown development. The open discharge is ignited between two planar cathodes with mesh anode in the middle between them. For gas pressure 6 Torr and 20 kV applied voltage, the rate of current rise reaches 500 A/(cm{sup 2} ns) for current density 200 A/cm{sup 2} and more. The time of breakdown development was measured for different helium pressures and a kinetic model of breakdown in open discharge is presented, based on elementary reactions for electrons, ions and fast atoms. The model also includes various cathode emission processes due to cathode bombardment by ions, fast atoms, electrons and photons of resonant radiation with Doppler shift of frequency. It is shown, that the dominating emission processes depend on the evolution of the discharge voltage during the breakdown. In the simulations, two cases of voltage behavior were considered: (i) the voltage is kept constant during the breakdown; (ii) the voltage is reduced with the growth of current. For the first case, the exponentially growing current is maintained due to photoemission by the resonant photons with Doppler-shifted frequency. For the second case, the dominating factor of current growth is the secondary electron emission. In both cases, the subnanosecond rise of discharge current was obtained. Also the effect of gas pressure on breakdown development was considered. It was found that for 20 Torr gas pressure the time of current rise decreases to 0.1 ns, which is in agreement with experimental data.

  8. Expert Meeting Report: Achieving the Best Installed Performance from High-Efficiency Residential Gas Furnaces

    Energy Technology Data Exchange (ETDEWEB)

    Brand, Larry [Partnership for Advanced Residential Retrofit (PARR), Des Plaines, IL (United States)

    2012-03-01

    This report describes a Building America expert meeting hosted on July 28, 2011, by the Partnership for Advanced Residential Retrofit (PARR) team. The purpose of this meeting was to identify installation practices that provide the best installed efficiency for residential gas furnaces, explain how AFUE and field efficiency can differ, and investigate the impact of installation practices on the efficiency and long-term durability of the furnace.

  9. Expert Meeting Report: Achieving the Best Installed Performance from High-Efficiency Residential Gas Furnaces

    Energy Technology Data Exchange (ETDEWEB)

    Brand, L.

    2012-03-01

    This report describes a Building America expert meeting hosted on July 28, 2011, by the Partnership for Advanced Residential Retrofit team. The purpose of this meeting was to identify installation practices that provide the best installed efficiency for residential gas furnaces, explain how AFUE and field efficiency can differ, and investigate the impact of installation practices on the efficiency and long-term durability of the furnace.

  10. Lateral Load-Resisting System Using Mass Timber Panel for High-Rise Buildings

    Directory of Open Access Journals (Sweden)

    Zhiyong Chen

    2017-07-01

    Full Text Available As global interest in using engineered wood products in tall buildings intensifies due to the “green” credential of wood, it is expected that more tall wood buildings will be designed and constructed in the coming years. This, however, brings new challenges to the designers. One of the major challenges is how to design lateral load-resisting systems (LLRSs with sufficient stiffness, strength, and ductility to resist strong wind and earthquakes. In this study, an LLRS using mass timber panel on a stiff podium was developed for high-rise buildings in accordance with capacity-based design principle. The LLRS comprises eight shear walls with a core in the center of the building, which was constructed with structural composite lumber and connected with dowel-type connections and wood–steel composite system. The main energy dissipating mechanism of the LLRS was detailed to be located at the panel-to-panel interface. This LLRS was implemented in the design of a hypothetical 20-storey building. A finite element (FE model of the building was developed using general-purpose FE software, ABAQUS. The wind-induced and seismic response of the building model was investigated by performing linear static and non-linear dynamic analyses. The analysis results showed that the proposed LLRS using mass timber was suitable for high-rise buildings. This study provided a valuable insight into the structural performance of LLRS constructed with mass timber panels as a viable option to steel and concrete for high-rise buildings.

  11. Upgrading Glasgow’s High-rise Building Stock – A Case Study

    OpenAIRE

    Menon, Rosalie

    2017-01-01

    The city of Glasgow contains the highest concentration of social housing tower blocks in the UK – however a quarter of Glasgow’s high-rises have been demolished in less than 10 years and many more are assigned for demolition as part of the city’s plans for regeneration. However, this is an intrinsically expensive route to achieving the required number of affordable, energy-efficient housing units and instead many of the surviving tower blocks have been subject to a programme of retrofit to im...

  12. Reliability of system identification technique in super high-rise building

    Directory of Open Access Journals (Sweden)

    Ayumi eIkeda

    2015-07-01

    Full Text Available A smart physical-parameter based system identification method has been proposed in the previous paper. This method deals with time-variant nonparametric identification of natural frequencies and modal damping ratios using ARX (Auto-Regressive eXogenous models and has been applied to high-rise buildings during the 2011 off the Pacific coast of Tohoku earthquake. In this perspective article, the current state of knowledge in this class of system identification methods is explained briefly and the reliability of this smart method is discussed through the comparison with the result by a more confident technique.

  13. Interference effects between two rectangular-section high-rise buildings on local peak pressure coefficients

    Science.gov (United States)

    Hui, Yi; Yoshida, Akihito; Tamura, Yukio

    2013-02-01

    This study investigates the interference effects between two rectangular-section high-rise buildings by wind tunnel experiments, focusing on local peak pressure coefficients. Wind tunnel experiments were carried out under 72 wind incidence angles for various configurations. Two building arrangements were considered: parallel and perpendicular. To evaluate the interference effects for local peak pressures in detail, interference factors for largest positive and smallest negative peak pressures are presented and discussed. The results show that interference effects greatly depend on configuration and wind direction. Unfavorable positions are generally concentrated at the edges and corners of a building. Flow visualization was also conducted to check the flow field between two buildings.

  14. Dynamics of number and daily activity of mosquitoes in high-rise buildings of Odessa city

    Directory of Open Access Journals (Sweden)

    І. T. Rusev

    2011-07-01

    Full Text Available Three species of mosquitoes, Culex pipiens L., Culiseta annulata Schrk. and Uranotaenia unguiculata Edw., were found in halls and subbasements of the high-rise buildings in Odessa city. Buildings with moist subbasements are suitable biotopes for mosquitoes round the year. Number of the mosquitoes from the fist to fifth floors of buildings declines. The mosquitoes spread from occupied moist living buildings to dry ones. The mosquitoes attack humans, rats and pigeons. Firstly in Ukraine the ecological type of Culex pipiens – C. p. pipiens f. molestus as a vector of the West Nile virus was found in the urban area.

  15. Mitigation of extremely low frequency magnetic fields from electrical installations in high-rise buildings

    Energy Technology Data Exchange (ETDEWEB)

    Burnett, John; Duyaping, Patrick [Hong Kong Polytechnic Univ., Dept. of Building Services Engineering, Kowloon, Hong Kong (China)

    2002-09-01

    The health impacts on people exposed to power line generated magnetic fields remains somewhat controversial. Under certain circumstances, such extremely low frequency (ELF) magnetic fields also arise in high-rise buildings in Hong Kong, causing interference with sensitive equipment, and with it concerns about the potential health impacts on affected persons. Due to a general lack of awareness electrical design and installation engineers rarely consider the issue. This paper discusses the problem of ELF fields generated by a building's electrical distribution system, and provides simplified analytical techniques that lead to practical solutions for eliminating interference problems as well as reducing concerns about health impacts. (Author)

  16. Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement

    CERN Document Server

    Troyer, G L

    2000-01-01

    High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise time of deposited gamma photons. Time discrimination was used to characterize the pulse r...

  17. Forensic entomology of high-rise buildings in Malaysia: Three case reports.

    Science.gov (United States)

    Syamsa, R A; Omar, B; Zuha, R M; Faridah, M N; Swarhib, M S; Hidayatulfathi, O; Shahrom, A W

    2015-06-01

    The distributions of flies are not only confined to ground level but can also be at higher altitudes. Here, we report three forensic cases involving dipterans in high-rise buildings in Kuala Lumpur, Malaysia. Case 1 involved a corpse of adult female found at the top floor of a fifteen-story apartment. Case 2 dealt with a body of a 75-year-old female discovered in a bedroom on the eleventh floor of an eighteen-story building, while Case 3 was a 52-year-old male found in his fifth floor shop house. Interestingly, entomological analysis revealed that all corpses were infested with similar Dipterans: Megaselia scalaris (Loew) (Diptera: Phoridae), Synthesiomyia nudiseta (Wulp) (Diptera: Muscidae) and sarcophagid (Diptera: Sarcophagidae). The first two species were commonly associated with corpses found indoors at ground level. We noted the additional occurrence of blowflies Chrysomya megacephala (Fabricius) (Diptera: Calliphoridae) and Chrysomya rufifacies Macquart (Diptera: Calliphoridae) larvae in Case 2 and Case 3, respectively. Findings from this study are significant as they demonstrate that certain groups of fly can locate dead bodies even in high-rise buildings. Forensic entomofauna research on corpses found at high elevation is scarce and our study has highlighted the peculiarity of the fly species involved in Malaysia.

  18. High-resolution tide projections reveal extinction threshold in response to sea-level rise.

    Science.gov (United States)

    Field, Christopher R; Bayard, Trina S; Gjerdrum, Carina; Hill, Jason M; Meiman, Susan; Elphick, Chris S

    2017-05-01

    Sea-level rise will affect coastal species worldwide, but models that aim to predict these effects are typically based on simple measures of sea level that do not capture its inherent complexity, especially variation over timescales shorter than 1 year. Coastal species might be most affected, however, by floods that exceed a critical threshold. The frequency and duration of such floods may be more important to population dynamics than mean measures of sea level. In particular, the potential for changes in the frequency and duration of flooding events to result in nonlinear population responses or biological thresholds merits further research, but may require that models incorporate greater resolution in sea level than is typically used. We created population simulations for a threatened songbird, the saltmarsh sparrow (Ammodramus caudacutus), in a region where sea level is predictable with high accuracy and precision. We show that incorporating the timing of semidiurnal high tide events throughout the breeding season, including how this timing is affected by mean sea-level rise, predicts a reproductive threshold that is likely to cause a rapid demographic shift. This shift is likely to threaten the persistence of saltmarsh sparrows beyond 2060 and could cause extinction as soon as 2035. Neither extinction date nor the population trajectory was sensitive to the emissions scenarios underlying sea-level projections, as most of the population decline occurred before scenarios diverge. Our results suggest that the variation and complexity of climate-driven variables could be important for understanding the potential responses of coastal species to sea-level rise, especially for species that rely on coastal areas for reproduction. © 2016 John Wiley & Sons Ltd.

  19. Fuel properties effect on the performance of a small high temperature rise combustor

    Science.gov (United States)

    Acosta, Waldo A.; Beckel, Stephen A.

    1989-01-01

    The performance of an advanced small high temperature rise combustor was experimentally determined at NASA-Lewis. The combustor was designed to meet the requirements of advanced high temperature, high pressure ratio turboshaft engines. The combustor featured an advanced fuel injector and an advanced segmented liner design. The full size combustor was evaluated at power conditions ranging from idle to maximum power. The effect of broad fuel properties was studied by evaluating the combustor with three different fuels. The fuels used were JP-5, a blend of Diesel Fuel Marine/Home Heating Oil, and a blend of Suntec C/Home Heating Oil. The fuel properties effect on the performance of the combustion in terms of pattern factor, liner temperatures, and exhaust emissions are documented.

  20. Multiloop Rapid-Rise/Rapid Fall High-Voltage Power Supply

    Science.gov (United States)

    Bearden, Douglas

    2007-01-01

    A proposed multiloop power supply would generate a potential as high as 1.25 kV with rise and fall times rise-time, and fall-time requirements. The power supply would include a preregulator that would be used to program a voltage 1/30 of the desired output voltage. By means of a circuit that would include a pulse-width modulator (PWM), two voltage doublers, and a transformer having two primary and two secondary windings, the preregulator output voltage would be amplified by a factor of 30. A resistor would limit the current by controlling a drive voltage applied to field-effect transistors (FETs) during turn-on of the PWM. Two feedback loops would be used to regulate the high output voltage. A pulse transformer would be used to turn on four FETs to short-circuit output capacitors when the outputs of the PWM were disabled. Application of a 0-to-5-V square to a PWM shut-down pin would cause a 20-to-1,250-V square wave to appear at the output.

  1. Air ventilation impacts of the "wall effect" resulting from the alignment of high-rise buildings

    Science.gov (United States)

    Yim, S. H. L.; Fung, J. C. H.; Lau, A. K. H.; Kot, S. C.

    The objective of this study is to investigate the air ventilation impacts of the so called "wall effect" caused by the alignment of high-rise buildings in complex building clusters. The research method employs the numerical algorithm of computational fluid dynamics (CFD - FLUENT) to simulate the steady-state wind field in a typical Hong Kong urban setting and investigate pollutant dispersion inside the street canyon utilizing a pollutant transport model. The model settings of validation study were accomplished by comparing the simulation wind field around a single building block to wind tunnel data. The results revealed that our model simulation is fairly close to the wind tunnel measurements. In this paper, a typical dense building distribution in Hong Kong with 2 incident wind directions (0° and 22.5°) is studied. Two performance indicators are used to quantify the air ventilation impacts, namely the velocity ratio ( VR) and the retention time ( T r) of pollutants at the street level. The results indicated that the velocity ratio at 2 m above ground was reduced 40% and retention time of pollutants increased 80% inside the street canyon when high-rise buildings with 4 times height of the street canyon were aligned as a "wall" upstream. While this reduction of air ventilation was anticipated, the magnitude is significant and this result clearly has important implications for building and urban planning.

  2. Modeling and measuring the indoor randon concentrations in high-rise buildings in Hong Kong.

    Science.gov (United States)

    Man, C K; Yeung, H S

    1999-06-01

    A newly constructed, uninhabited high-rise building has been measured for its indoor and outdoor radon concentrations at similar locations on each of the 18 floor levels. Grab sampling technique has been used so that many locations can be measured within short period of time to minimize the variations due to temperature, pressure and humidity. Air exchange rates inside rooms were obtained by tracer gas method. Standard concrete samples were manufactured in laboratory to simulate the concrete used in the construction of the high-rise building. The concrete samples were measured for their radon exhalation rates by calculating the initial growth rates of radon inside an airtight container. The air exchange rates have been found to increase with floor levels, whilst the indoor and outdoor radon concentrations decreased with floor levels. Using a model utilizing a simple mass balance equation, the indoor radon concentration inside a room on each of the 18 floor levels has been calculated and the results agreed very well with measurements.

  3. Modeling and measuring the indoor radon concentrations in high-rise buildings in Hong Kong

    Energy Technology Data Exchange (ETDEWEB)

    Man, C.K.; Yeung, H.S

    1999-06-01

    A newly constructed, uninhabited high-rise building has been measured for its indoor and outdoor radon concentrations at similar locations on each of the 18 floor levels. Grab sampling technique has been used so that many locations can be measured within short period of time to minimize the variations due to temperature, pressure and humidity. Air exchange rates inside rooms were obtained by tracer gas method. Standard concrete samples were manufactured in laboratory to simulate the concrete used in the construction of the high-rise building. The concrete samples were measured for their radon exhalation rates by calculating the initial growth rates of radon inside an airtight container. The air exchange rates have been found to increase with floor levels, whilst the indoor and outdoor radon concentrations decreased with floor levels. Using a model utilizing a simple mass balance equation, the indoor radon concentration inside a room on each of the 18 floor levels has been calculated and the results agreed very well with measurements.

  4. On Roof Geometry for Urban Wind Energy Exploitation in High-Rise Buildings

    Directory of Open Access Journals (Sweden)

    Francisco Toja-Silva

    2015-06-01

    Full Text Available The European program HORIZON2020 aims to have 20% of electricity produced by renewable sources. The building sector represents 40% of the European Union energy consumption. Reducing energy consumption in buildings is therefore a priority for energy efficiency. The present investigation explores the most adequate roof shapes compatible with the placement of different types of small wind energy generators on high-rise buildings for urban wind energy exploitation. The wind flow around traditional state-of-the-art roof shapes is considered. In addition, the influence of the roof edge on the wind flow on high-rise buildings is analyzed. These geometries are investigated, both qualitatively and quantitatively, and the turbulence intensity threshold for horizontal axis wind turbines is considered. The most adequate shapes for wind energy exploitation are identified, studying vertical profiles of velocity, turbulent kinetic energy and turbulence intensity. Curved shapes are the most interesting building roof shapes from the wind energy exploitation point of view, leading to the highest speed-up and the lowest turbulence intensity.

  5. Wind-Induced Fatigue Analysis of High-Rise Steel Structures Using Equivalent Structural Stress Method

    Directory of Open Access Journals (Sweden)

    Zhao Fang

    2017-01-01

    Full Text Available Welded beam-to-column connections of high-rise steel structures are susceptive to fatigue damage under wind loading. However, most fatigue assessments in the field of civil engineering are mainly based on nominal stress or hot spot stress theories, which has the disadvantage of dependence on the meshing styles and massive curves selected. To address this problem, in this paper, the equivalent structural stress method with advantages of mesh-insensitive quality and capability of unifying different stress-life curves (S-N curves into one is introduced to the wind-induced fatigue assessment of a large-scale complicated high-rise steel structure. The multi-scale finite element model is established and the corresponding wind loading is simulated. Fatigue life assessments using equivalent structural stress method, hot spot stress method and nominal stress method are performed, and the results are verified and comparisons are made. The mesh-insensitive quality is also verified. The results show that the lateral weld toe of the butt weld connecting the beam flange plate and the column is the location where fatigue damage most likely happens. Nominal stress method considers fatigue assessment of welds in a more global way by averaging all the stress on the weld section while in equivalent structural stress method and hot spot method local stress concentration can be taken into account more precisely.

  6. An optically coupled power stimulus isolation unit with high voltage and fast rise time output

    Directory of Open Access Journals (Sweden)

    R.O. Brasil

    1999-06-01

    Full Text Available Recent technological developments have created new devices that could improve and simplify the construction of stimulus isolators. HEXFET transistors can switch large currents and hundreds of volts in nanoseconds. The newer opto-isolators can give a pulse rise time of a few nanoseconds, with output compatible with MOSFET devices, in which delays are reduced to nanoseconds. Integrated DC/DC converters are now available. Using these new resources we developed a new electrical stimulus isolator circuit with selectable constant-current and constant-voltage modes, which are precise and easy to construct. The circuit works like a regulated power supply in both modes with output switched to zero or to free mode through an opto-isolator device. The isolator analyses showed good practical performance. The output to ground resistance was 1011 ohms and capacitance 35 picofarads. The rise time and fall time were identical (5 µs and constant. The selectable voltage or current output mode made it very convenient to use. The current mode, with higher output resistance values in low current ranges, permits intracellular stimulation even with tip resistances close to 100 megaohms. The high compliance of 200 V guarantees the value of the current stimulus. The very low output resistance in the voltage mode made the device highly suitable for extracellular stimulation with low impedance electrodes. Most importantly, these characteristics were achieved with a circuit that was easy to build and modify and assembled with components available in Brazil.

  7. An optically coupled power stimulus isolation unit with high voltage and fast rise time output.

    Science.gov (United States)

    Brasil, R O; Leal-Cardoso, J H

    1999-06-01

    Recent technological developments have created new devices that could improve and simplify the construction of stimulus isolators. HEXFET transistors can switch large currents and hundreds of volts in nanoseconds. The newer opto-isolators can give a pulse rise time of a few nanoseconds, with output compatible with MOSFET devices, in which delays are reduced to nanoseconds. Integrated DC/DC converters are now available. Using these new resources we developed a new electrical stimulus isolator circuit with selectable constant-current and constant-voltage modes, which are precise and easy to construct. The circuit works like a regulated power supply in both modes with output switched to zero or to free mode through an opto-isolator device. The isolator analyses showed good practical performance. The output to ground resistance was 10(11) ohms and capacitance 35 picofarads. The rise time and fall time were identical (5 microseconds) and constant. The selectable voltage or current output mode made it very convenient to use. The current mode, with higher output resistance values in low current ranges, permits intracellular stimulation even with tip resistances close to 100 megaohms. The high compliance of 200 V guarantees the value of the current stimulus. The very low output resistance in the voltage mode made the device highly suitable for extracellular stimulation with low impedance electrodes. Most importantly, these characteristics were achieved with a circuit that was easy to build and modify and assembled with components available in Brazil.

  8. The Rise of High-Stakes Educational Testing in Denmark (1920-1970)

    DEFF Research Database (Denmark)

    Ydesen, Christian

    The Rise of High-Stakes Educational Testing in Denmark (1920–1970) is an attempt to determine why and how tests rose to prominence in an educational system that used to rely on qualitative tests and teacher evaluations. The study addresses the important issues of how testing interacts...... with and influences an educational system, and which common factors are involved in order to implement testing in an educational system. The study is based on three relatively unknown case studies – illustrious examples of high-stakes educational testing practices in the Danish public school system. The first case...... study discusses the sorting of children into remedial education based on standardised intelligence testing in the Frederiksberg municipality from 1930 to 1943. The second case study deals with the comprehensive testing programme conducted at the Copenhagen experimental school of Emdrupborg from 1948...

  9. Building automation in high-rise buildings: the Eurotheum; Gebaeudeautomation in Hochhaeusern am Beispiel Eurotheum

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, V. [Canzler Ingenieure GmbH, Muelheim an der Ruhr (Germany)

    2000-03-01

    Flexibility of space division and space use as well as economy are overriding objectives in the technical equipment of multifunctional buildings. Building automation controls all technical systems, establishes links between systems and supports building management. Relevant problem solutions are discussed with reference to the Eurotheum high-rise building in Frankfurt/Main, a building with office, business and sales areas meeting high demands. (orig.) [German] Flexible Raumgestaltung und Raumnutzung sowie Wirtschaftlichkeit sind die vorrangigen Anforderung an die Technische Ausruestung in multifunktionalen Gebaeuden. Die Gebaeudeautomation regelt und steuert alle technischen Anlagen, schafft gewerkeuebergreifende Verbindungen und unterstuetzt das Gebaeudemanagement. Am Beispiel des Hochhauses Eurotheum in Frankfurt/M. mit hochwertigen Wohnungen, Buero-, Handels- und Verkaufsflaechen werden Loesungen dazu erlaeutert. (orig.)

  10. Pulse generator using transistors and silicon controlled rectifiers produces high current pulses with fast rise and fall times

    Science.gov (United States)

    Woolfson, M. G.

    1966-01-01

    Electrical pulse generator uses power transistors and silicon controlled rectifiers for producing a high current pulse having fast rise and fall times. At quiescent conditions, the standby power consumption of the circuit is equal to zero.

  11. Spatiotemporal Effects of Main Impact Factors on Residential Land Price in Major Cities of China

    Directory of Open Access Journals (Sweden)

    Shengfu Yang

    2017-11-01

    Full Text Available With the rapid development of land marketization in China, the spatial patterns of residential land prices in different regions have become increasingly complicated. The very high and continuously rising residential land prices in many cities are causing significant challenges to economic development and social stability. Yet, there has only been a limited amount of attempts made to model and analyze the regional dynamic changes of residential land price systematically, especially in term of the spatially varying effects of key demographic and economic factors. In this study we provided a perspective analysis of the changes of residential land prices in 2008, 2011 and 2014 based on the land price monitoring records of 105 cities and then conducted a geographically weighted regression (GWR analysis on the relationships between residential land price and three major impact factors (i.e., immigrant population, gross domestic product (GDP and investment in residential buildings. Results show that the areas in which GDP had relatively strong positive impacts on residential land price expanded with time. The negative effects of immigrant population on residential land price were mainly concentrated in the cities around the Bohai Rim and the area with negative effects gradually shrank in the three studied years. Conversely, the areas with negative correlation between investment in residential buildings and residential land price gradually expanded in size over time. A geographical detector was used to examine the relative importance of factors to residential land price. It was found that the GDP had more significant influence on residential land price than other factors and the influence of the three factors to overall variation in residential land price increased over the three studied years. These results underscore the importance of taking spatially varying effects of major driving factors into account in policy-making on regional land market.

  12. Modeling residential lawn fertilization practices: integrating high resolution remote sensing with socioeconomic data

    Science.gov (United States)

    Weiqi Zhou; Austin Troy; Morgan. Grove

    2008-01-01

    This article investigates how remotely sensed lawn characteristics, such as parcel lawn area and parcel lawn greenness, combined with household characteristics, can be used to predict household lawn fertilization practices on private residential lands. This study involves two watersheds, Glyndon and Baisman's Run, in Baltimore County, Maryland, USA. Parcel lawn...

  13. High-rise buildings under multi-hazard environment assessment and design for optimal performance

    CERN Document Server

    Huang, Mingfeng

    2017-01-01

    This book discusses performance-based seismic and wind-resistant design for high-rise building structures, with a particular focus on establishing an integrated approach for performance-based wind engineering, which is currently less advanced than seismic engineering. This book also provides a state-of-the-art review of numerous methodologies, including computational fluid dynamics (CFD), extreme value analysis, structural optimization, vibration control, pushover analysis, response spectrum analysis, modal parameter identification for the assessment of the wind-resistant and seismic performance of tall buildings in the design stage and actual tall buildings in use. Several new structural optimization methods, including the augmented optimality criteria method, have been developed and employed in the context of performance-based design. This book is a valuable resource for students, researchers and engineers in the field of civil and structural engineering.

  14. CONSIDERATION OF TEMPERATURE, FORCE AND SHRINKING CORRECTIONS DURING VERTICAL GEODESIC SURVEY OF HIGH-RISE BUILDINGS

    Directory of Open Access Journals (Sweden)

    M. Nesterenok

    2013-01-01

    Full Text Available The paper shows  that  in order to ensure designed geometry of  a constructed high-rise building and while handing over design elevations for installation horizons it is necessary to take into account its vertical deformations  in the form of the following corrections in geodetic vertical distances: temperature, force (caused by structure weight and shrinking (caused by concrete drying-out. The paper gives an example of actual vertical deformation of a building frame from in-situ reinforced concrete at several elevations including  a maximum one – 104.9 m.  Data of the paper can be used in practical work.

  15. Collapse Scenarios of High-Rise Buildings Using Plastic Limit Analysis

    Directory of Open Access Journals (Sweden)

    G. Liu

    2009-01-01

    Full Text Available The Twin Towers of the World Trade Center (WTC in New York, USA collapsed on 11 September, 2001. The incident is regarded as the most severe disaster for high-rise buildings in history. Investigations into the collapse scenarios are still being conducted. Possible collapse scenarios assessed by local and international experts were reported. Another possible collapse scenario of the WTC based on two hypotheses was proposed in this paper, and the idea of plastic limit analysis was applied to evaluate the approximate limit load. According to the theory analysis and numerical calculations, a conclusion can be drawn that the large fires, aroused by the terrorist attack, play a significant role on the collapse of the WTC.

  16. Rapid method for surveying CO concentrations in high-rise buildings

    Energy Technology Data Exchange (ETDEWEB)

    Flachsbart, P.G.; Ott, W.R.

    1986-01-01

    A rapid method for employing personal exposure monitors (PEMs) to measure carbon monoxide (CO) concentrations in high-rise buildings is described. The purpose is to determine whether or not a CO problem exists in a building, and, if so, what corrective actions should be taken. The methodology was applied to a 15-story building in Palo Alto, CA, where elevated CO concentrations were discovered on the first 11 floors. The source appeared to be an underground parking garage. A follow-up survey four years later revealed that mitigative measures designed to reduce these concentrations had been successful. The survey methodology is inexpensive and can be applied to a number of buildings in a city.

  17. Control strategies for window opening systems of high-rise buildings; Steuerungsstrategien fuer Fensterbetaetigungen von Hochhaeusern

    Energy Technology Data Exchange (ETDEWEB)

    Gerhardt, H.J. [Technische Hochschule Aachen (Germany). Lehrstuhl und Inst. fuer Luft- und Raumfahrt; Rudolph, M. [IFI Institut fuer Industrieaerodynamik GmbH, Aachen (Germany)

    2000-09-01

    Natural ventilation should be ensured in modern high-rise buildings as far as possible. Double-shell walls are required if windows are to be completely openable. Without double-shell walls, only limited opening of windows is possible, e.g. parallel to the building wall as in the new 'Main-Tower II' building in Frankfurt. [German] Die Raeumlichkeiten moderner Hochhaeuser sollen ueber einen moeglichst grossen Teil des Jahres natuerlich be- und entlueftet werden. Will man die Fenster in den Aussenwaenden der Hochhaeuser fuer Lueftungszwecke vollstaendig oeffnen koennen, macht dies eine Doppelfassade erforderlich. Will man auf eine Doppelfassade verzichten, muss die Oeffnung der Fenster begrenzt werden. Guenstig ist hier eine Verstellung des Fensters parallel zur Gebaeudewand. Dieses Konzept wurde kuerzlich am Main-Tower II in Frankfurt realisiert. (orig.)

  18. High-Voltage Power Supply With Fast Rise and Fall Times

    Science.gov (United States)

    Bearden, Douglas B.; Acker, Richard M.; Kapuslka, Robert E.

    2007-01-01

    A special-purpose high-voltage power supply can be electronically switched on and off with fast rise and fall times, respectively. The output potential is programmable from 20 to 1,250 V. An output current of 50 A can be sustained at 1,250 V. The power supply was designed specifically for electronically shuttering a microchannel plate in an x-ray detector that must operate with exposure times as short as 1 ms. The basic design of the power supply is also adaptable to other applications in which there are requirements for rapid slewing of high voltages. The power-supply circuitry (see figure) includes a preregulator, which is used to program the output at 1/30 of the desired output potential. After the desired voltage has been set, the outputs of a pulse width modulator (PWM) are enabled and used to amplify the preregulator output potential by 30. The amplification is achieved by use of two voltage doublers with a transformer that has two primary and two secondary windings. A resistor is used to limit the current by controlling the drive voltage of two field-effect transistors (FETs) during turn-on of the PWM. A pulse transformer is used to turn on four FETs to short-circuit four output capacitors when the outputs of the PWM have been disabled. The most notable aspects of the performance of the power supply are a rise time of only 80 s and a fall time of only 60 s at a load current of 50 A or less. Another notable aspect is that the application of a 0-to-5-V square wave to a shutdown pin of the PWM causes the production of a 0-to-1,250-V square wave at the output terminals.

  19. The High Resolution Imaging Science Experiment (HiRISE) during MRO's Primary Science Phase (PSP)

    Science.gov (United States)

    McEwen, A.S.; Banks, M.E.; Baugh, N.; Becker, K.; Boyd, A.; Bergstrom, J.W.; Beyer, R.A.; Bortolini, E.; Bridges, N.T.; Byrne, S.; Castalia, B.; Chuang, F.C.; Crumpler, L.S.; Daubar, I.; Davatzes, A.K.; Deardorff, D.G.; DeJong, A.; Alan, Delamere W.; Dobrea, E.N.; Dundas, C.M.; Eliason, E.M.; Espinoza, Y.; Fennema, A.; Fishbaugh, K.E.; Forrester, T.; Geissler, P.E.; Grant, J. A.; Griffes, J.L.; Grotzinger, J.P.; Gulick, V.C.; Hansen, C.J.; Herkenhoff, K. E.; Heyd, R.; Jaeger, W.L.; Jones, D.; Kanefsky, B.; Keszthelyi, L.; King, R.; Kirk, R.L.; Kolb, K.J.; Lasco, J.; Lefort, A.; Leis, R.; Lewis, K.W.; Martinez-Alonso, S.; Mattson, S.; McArthur, G.; Mellon, M.T.; Metz, J.M.; Milazzo, M.P.; Milliken, R.E.; Motazedian, T.; Okubo, C.H.; Ortiz, A.; Philippoff, A.J.; Plassmann, J.; Polit, A.; Russell, P.S.; Schaller, C.; Searls, M.L.; Spriggs, T.; Squyres, S. W.; Tarr, S.; Thomas, N.; Thomson, B.J.; Tornabene, L.L.; Van Houten, C.; Verba, C.; Weitz, C.M.; Wray, J.J.

    2010-01-01

    The High Resolution Imaging Science Experiment (HiRISE) on the Mars Reconnaissance Orbiter (MRO) acquired 8 terapixels of data in 9137 images of Mars between October 2006 and December 2008, covering ???0.55% of the surface. Images are typically 5-6 km wide with 3-color coverage over the central 20% of the swath, and their scales usually range from 25 to 60 cm/pixel. Nine hundred and sixty stereo pairs were acquired and more than 50 digital terrain models (DTMs) completed; these data have led to some of the most significant science results. New methods to measure and correct distortions due to pointing jitter facilitate topographic and change-detection studies at sub-meter scales. Recent results address Noachian bedrock stratigraphy, fluvially deposited fans in craters and in or near Valles Marineris, groundwater flow in fractures and porous media, quasi-periodic layering in polar and non-polar deposits, tectonic history of west Candor Chasma, geometry of clay-rich deposits near and within Mawrth Vallis, dynamics of flood lavas in the Cerberus Palus region, evidence for pyroclastic deposits, columnar jointing in lava flows, recent collapse pits, evidence for water in well-preserved impact craters, newly discovered large rayed craters, and glacial and periglacial processes. Of particular interest are ongoing processes such as those driven by the wind, impact cratering, avalanches of dust and/or frost, relatively bright deposits on steep gullied slopes, and the dynamic seasonal processes over polar regions. HiRISE has acquired hundreds of large images of past, present and potential future landing sites and has contributed to scientific and engineering studies of those sites. Warming the focal-plane electronics prior to imaging has mitigated an instrument anomaly that produces bad data under cold operating conditions. ?? 2009 Elsevier Inc.

  20. Structural vibration passive control and economic analysis of a high-rise building in Beijing

    Science.gov (United States)

    Chen, Yongqi; Cao, Tiezhu; Ma, Liangzhe; Luo, Chaoying

    2009-12-01

    Performance analysis of the Pangu Plaza under earthquake and wind loads is described in this paper. The plaza is a 39-story steel high-rise building, 191 m high, located in Beijing close to the 2008 Olympic main stadium. It has both fluid viscous dampers (FVDs) and buckling restrained braces or unbonded brace (BRB or UBB) installed. A repeated iteration procedure in its design and analysis was adopted for optimization. Results from the seismic response analysis in the horizontal and vertical directions show that the FVDs are highly effective in reducing the response of both the main structure and the secondary system. A comparative analysis of structural seismic performance and economic impact was conducted using traditional methods, i.e., increased size of steel columns and beams and/or use of an increased number of seismic braces versus using FVD. Both the structural response and economic analysis show that using FVD to absorb seismic energy not only satisfies the Chinese seismic design code for a “rare” earthquake, but is also the most economical way to improve seismic performance both for one-time direct investment and long term maintenance.

  1. Assessment of rainwater use and greywater reuse in high-rise buildings in a brownfield site.

    Science.gov (United States)

    Zhang, Yan; Grant, Andrew; Sharma, Ashok; Chen, Donghui; Chen, Liang

    2009-01-01

    This study describes the use of rainwater and greywater (originated from bathroom only) for provision of non-contact indoor and outdoor use in high-rise buildings. A brownfield development site in Box Hill suburb of Melbourne was selected as case study site for this investigation. The performance of alternative servicing options was compared with conventional water supply, stormwater and wastewater servicing. A water balance model UVQ (Urban Volume and Quality) was applied to determine storage capacities and to evaluate the percentage reduction in water supplying, stormwater run-off and wastewater disposal, as well as volumes of rainwater use and greywater reuse. In this study, the impact of variation in collection area (600 m(2) and 900 m(2)) and appliance discharge volumes was examined. A number of demand management options were also investigated. The results of this study indicate greywater reuse is more suited than rainwater use for this development because of the steady, constant supply of greywater compared to the highly fluctuating, storm-event supply of rainwater and the high population density creating comparatively large volumes of greywater.

  2. Effective utilization of energy in high-rise buildings; Chokoso biru deno energy yuko riyo

    Energy Technology Data Exchange (ETDEWEB)

    Kumagai, T. [Hokkaido Univ., Sapporo (Japan). Faculty of Engineering

    1996-04-20

    At present, many buildings more than 100m high above the ground have been built in Japan. Techniques for energy saving in buildings are divided into the architectural techniques and the techniques of using facilities, but in this article, the especially important techniques for energy saving in high-rise buildings are introduced. In other words, regarding the skin planning, they are enhancement of cutoff of insolation (pent roof, electrically operated blind, etc.) and prevention of draft (improvement of airtightness of curtain wall, etc.). Concerning reduction of carrier power, carrier transmission by big temperature difference, control of number of pumps and revolution control, variable air quantity and variable flow, and reduction of pressure loss. Also with regard to energy saving of electrical equipment, are listed reduction of illumination energy (adoption of high efficiency lighting equipment, control switching lights off, etc.), power distribution plan (dispersed arrangement of switch houses, reduction of transmission loss by increase of working voltage, etc.), and a energy saving plan for elevators. As the techniques in the future, cogeneration with fuel cells, etc. are pointed out. 7 figs., 2 tabs.

  3. CFD Simulation of Spread Risks of Infectious Disease due to Interactive Wind and Ventilation Airflows via Window Openings in High-Rise Buildings

    Science.gov (United States)

    Niu, J. L.; Gao, N. P.

    2010-05-01

    One of the concerns is that there may exist multiple infectious disease transmission routes across households in high-rise residential buildings, one of which is the natural ventilative airflow through open windows between flats, caused by buoyancy effects. This study presents the modeling of this cascade effect using computational fluid dynamics (CFD) technique. It is found that the presence of the pollutants generated in the lower floor is generally lower in the immediate upper floor by two orders of magnitude, but the risk of infection calculated by the Wells-Riley equation is only around one order of magnitude lower. It is found that, with single-side open-window conditions, wind blowing perpendicularly to the building may either reinforce or suppress the upward transport, depending on the wind speed. High-speed winds can restrain the convective transfer of heat and mass between flats, functioning like an air curtain. Despite the complexities of the air flow involved, it is clear that this transmission route should be taken into account in infection control.

  4. High-rise buildings and neurologically favorable outcome after out-of-hospital cardiac arrest.

    Science.gov (United States)

    Kobayashi, Daisuke; Kitamura, Tetsuhisa; Kiyohara, Kosuke; Nishiyama, Chika; Hayashida, Sumito; Fujii, Tomoko; Izawa, Junichi; Shimamoto, Tomonari; Matsuyama, Tasuku; Hatakeyama, Toshihiro; Katayama, Yusuke; Kiguchi, Takeyuki; Kawamura, Takashi; Iwami, Taku

    2016-12-01

    The number of people living in high-rise buildings has recently been increasing in Japan, and delayed transport time by emergency-medical-service (EMS) personnel from higher floors could lead to lower survival after out-of-hospital cardiac arrest (OHCA). However, there are no clinical studies assessing the association between the floor where patients reside and neurologically favorable outcome after OHCA. This was a prospective, population-based study conducted in Osaka City, Japan that enrolled adults aged >=18years suffering an OHCA of cardiac origin before EMS arrival between 2013 and 2014. The primary outcome measure was one-month survival with neurologically favorable outcome. We divided OHCA patients into the following groups: those residing on >=3 floors (the high floor group) and <3 floors (the low floor group). Multiple logistic regression analysis was used to assess factors associated with neurologically favorable outcome. A total of 2979 patients were eligible for analysis. Of them, 1885 (62.3%) occurred below the third floor and 1094 (37.4%) occurred at or above the third floor. The proportion of neurologically favorable outcome after OHCA was significantly lower in the high floor group than in the low floor group (2.7% [30/1094] versus 4.8% [91/1885], P=0.005). In a multivariate analysis, neurologically favorable outcome after OHCA was significantly lower in the high floor group than in the low floor group (adjusted odds ratio, 0.59 [95% confidence interval, 0.37-0.96]). In this population, one-month survival with neurologically favorable outcome from OHCA was lower in the high floor group than in the low floor group. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Criteria of Architectural Composition Design in Residential Courtyards

    Science.gov (United States)

    Ziemeļniece, Aija; Īle, Una

    2017-10-01

    The totalitarian times of the 50s-80s of the 20th century have brought the building of high-rise residential blocks in Latvian cities, characterized by an uninteresting solution of standard buildings and the alien scale which does not meet the regional features. During the above period, areas of the residential courtyards have not been addressed. The conclusion of the research is that today the courtyards of the high-rise residential houses have become a stagnant, functionally irrelevant area that forms a depressing nature of the outdoor living space. The uncharted area of courtyards is not being used fully which highlights a wide range of issues that applies to car parks, recreation areas, and the green areas. With the development of the urban infrastructure, the creation of high-rise parking facilities and separate car parks are insufficiently addressed. Consequently, the implementation of improvements in courtyards of high-rise residential houses is not possible if the above issue on the removal of the car load from courtyards is not solved. Many building districts are characterized by the same compositional, architectural-spatial structure which even more influences and causes discomfort in these areas to stay. In recent years, the solution to the above issue is sought by the municipal authorities of Latvia to create a new courtyard zoning. It applies to the project development and construction works. In the research, courtyards of the city of Jelgava are analysed and evaluated which from the qualitative point of view demonstrates and is a vivid example where the issues of the research are readable. The city of Jelgava, located 45 km away from Riga, is an expressed satellite city and serves for the agglomeration of Riga as a huge high-rise residential district. Consequently, the research includes separate courtyards of high-rise residential buildings of the city of Jelgava and their study is carried out from the point of view of the architectural composition

  6. High-rise buildings threats microclimate in cities; Hochhaeuser bedrohen das Windklima unserer Staedte

    Energy Technology Data Exchange (ETDEWEB)

    Visser, G. [TNO-MEP, Apeldoorn (Netherlands)

    2001-04-01

    The tendency to erect tall buildings is threatening the microclimate in our cities. Furthermore, the compact cities from the past are more and more opened up by broad avenues because of increasing traffic flows. Only few people are aware that high-rise buildings also introduce local gales in our cities. As a consequence, our cities, which used to be so comfortable and compact, are changing into open, windy draft-holes, with even the risk of people being blown off their feet by sudden gusts. It is very important to keep a close track of these developments and to investigate the effects of a high-rise block in the local microclimate each time when such a building is planned. At the design stage it is often possible to remedy adverse effects or at least to bring them under control. The article describes how wind problems arise and what is to be born in mind to recognize potential threats to the wind comfort at the design stage. Then it is described how to determine the wind climate near buildings and in urban areas. The computer programme KnoWind often can be a very useful tool for a first check of potential wind nuisance. If a building appears to be sensitive to wind nuisance, however, further testing in an atmospheric boundary-layer wind tunnel is necessary. A rule of thumb is that buildings taller than 50 m should be subjected to wind tunnel testing. A wind tunnel example show how the wind climate can become worse as a result of erection of a tall building and how specific measures can help to set off this disadvantage. (orig.) [German] In diesem Beitrag wird eroertert, wie der Windkomfort beeintraechtigt wird und worauf man achten soll, um moegliche Windprobleme bereits auf dem Reissbrett erkennen zu koennen. Anschliessend wird beschrieben, wie man bei Gebaeuden und im staedtischen Bereich das Windklima bestimmen kann. Fuer eine erste Erkundung der moeglichen Windempflindlichkeit eines Gebaeudes kann oft das Computerprogramm KnoWind eingesetzt werden. Wenn es sich

  7. Appearance Principles of High Rise Buildings in the City Center: Visual Efect to Historical Heritage, Regulation Proposals

    Directory of Open Access Journals (Sweden)

    Lina Panavaitė

    2016-04-01

    Full Text Available High rise buildings is the phenomenon of XXI century, the expression of city’s economic and political power. This is the reflection of contemporary, modern and attractive city. Very often high rise buildings, who are characterized by a unique morphology, the parameters of high, density and intensity, are built near the historic center areas and cause irreversible visual impact on the historic sites, fundamentally altering the silhouette of the city. As a result, new problems and challenges appear. In this article the evolution of high rise buildings according to London, Jerusalem, Ottawa, Vilnius cities examples is analysed, the latest methodological principles which are applicable to control the development of high-rise buildings in the central parts of the city, while providing preservation and representation of cultural heritage are discussed. The latest computer technologies which are applied in urban regulations are presented. In case of Lithuania, high-rise building spatial development, general, spatial planning documents, urban design concepts, and monitoring of virtual city panoramas are reviewed. Comparative analysis in order to find out the essential methodological differences between cities regulation systems is done.

  8. FEATURES APPLICATION OF A CONSTRUCTION METHOD «UP – DOWN» IN THE HIGH-RISE BUILDINGS CONSTRUCTION

    Directory of Open Access Journals (Sweden)

    ZAIATS Y. I.

    2017-01-01

    Full Text Available Formulation of the problem. The present level of construction technology development enhances the choice relevance of the most efficient organizational and technological solutions of high-rise buildings construction. Execution of construction works is associated with many conditions, which greatly complicate their production, which in turn can lead to an actual cost increase of contractors to perform the whole complex of construction works. The process of high-rise buildings construction has specific differences, especially in terms of construction technology and organization, construction-related in conditions of the functioning structures of large cities and the existing infrastructure, the account of which will neutralize or localize the negative impact of destabilizing factors. Therefore, the design of high-rise construction organizations need to consider the influence of various destabilizing factors and implement the most efficient and modern construction methods. Goal. Determination of features and advantages of the method "up - down" in high-rise buildings construction in dense urban areas. Conclusion. Improving of the design solutions efficiency of high-rise buildings construction and their implementation, especially, time and cost reducing of construction, can be achieved by applying the construction method of the "top - down", which requires a higher organization of labor, the use of appropriate construction machinery, equipping and instrumentation, high requirements for health and safety.

  9. Potential Effect and Analysis of High Residential Solar Photovoltaic (PV Systems Penetration to an Electric Distribution Utility (DU

    Directory of Open Access Journals (Sweden)

    Jeffrey Tamba Dellosa

    2016-11-01

    Full Text Available The Renewable Energy Act of 2008 in the Philippines provided an impetus for residential owners to explore solar PV installations at their own rooftops through the Net-Metering policy. The Net-Metering implementation through the law however presented some concerns with inexperienced electric DU on the potential effect of high residential solar PV system installations. It was not known how a high degree of solar integration to the grid can possibly affect the operations of the electric DU in terms of energy load management. The primary objective of this study was to help the local electric DU in the analysis of the potential effect of high residential solar PV system penetration to the supply and demand load profile in an electric distribution utility (DU grid in the province of Agusan del Norte, Philippines. The energy consumption profiles in the year 2015 were obtained from the electric DU operating in the area. An average daily energy demand load profile was obtained from 0-hr to the 24th hour of the day based from the figures provided by the electric DU. The assessment part of the potential effect of high solar PV system integration assumed four potential total capacities from 10 Mega Watts (MW to 40 MW generated by all subscribers in the area under study at a 10 MW interval. The effect of these capacities were measured and analyzed with respect to the average daily load profile of the DU. Results of this study showed that a combined installations beyond 20 MWp coming from all subscribers is not viable for the local electric DU based on their current energy demand or load profile. Based from the results obtained, the electric DU can make better decisions in the management of high capacity penetration of solar PV systems in the future, including investment in storage systems when extra capacities are generated. Article History: Received July 15th 2016; Received in revised form Sept 23rd 2016; Accepted Oct 1st 2016; Available online How to Cite

  10. Fire Risk Analysis and Optimization of Fire Prevention Management for Green Building Design and High Rise Buildings: Hong Kong Experience

    Directory of Open Access Journals (Sweden)

    Yau Albert

    2014-12-01

    Full Text Available There are many iconic high rise buildings in Hong Kong, for example, International Commercial Centre, International Financial Centre, etc. Fire safety issue in high rise buildings has been raised by local fire professionals in terms of occupant evacuation, means of fire-fighting by fire fighters, sprinkler systems to automatically put off fires in buildings, etc. Fire risk becomes an important issue in building fire safety because it relates to life safety of building occupants where they live and work in high rise buildings in Hong Kong. The aim of this research is to identify the fire risk for different types of high rise buildings in Hong Kong and to optimise the fire prevention management for those high rise buildings with higher level of fire risk and to validate the model and also to carry out the study of the conflict between the current fire safety building code and the current trend of green building design. Survey via the 7-point scale questionnaire was conducted through 50 participants and their responses were received and analysed via the statistical tool SPSS software computer program. A number of statistical methods of testing for significantly difference in samples were adopted to carry out the analysis of the data received. When the statistical analysis was completed, the results of the data analysis were validated by two Fire Safety Experts in this area of specialisation and also by quantitative fire risk analysis.

  11. Impacts of orientation on daylighting in high-rise office buildings in Malaysia

    Directory of Open Access Journals (Sweden)

    AbdolHamid Mahdavi

    2015-12-01

    Full Text Available Orientation is one of the important factors in building design to use daylight and ‎conserve energy. Well-orientated buildings maximise daylight reception through ‎building facades and reduce the need for artificial lighting. Reasonable daylighting usage in office buildings is an important part of an architect’s designing process, which leads to lesser electricity consumption as well as providing a visual and thermal comfort for the occupants. Orientation is an important factor in passive design strategies. This paper focuses on the orientation effect on daylighting into office rooms. The research method of this study was simulation which is performed on a hypothetical model on a 25 storey high-rise office building in Malaysia. All simulations were carried out in the IES-VE software that uses RADIANCE program for illuminance calculations. To evaluate the daylight in various conditions, a new index SAZ was introduced which assesses daylight factor (DF and absolute Lux. Results showed similar SAZ in CIE overcast sky in various orientations; whereas, in sunny sky due to sun path in Malaysia, different results showed northern and southern rooms have the best illuminance distribution. However, the similar window form and size in four orientations lead to more energy consumption for artificial lighting and cooling loads.

  12. Hybrid Life Cycle Assessment of Low, Mid and High-Rise Multi-Family Dwellings

    Directory of Open Access Journals (Sweden)

    Kimberly Bawden

    2015-04-01

    Full Text Available We undertake Life Cycle Assessment (LCA of the cumulative energy demand (CED and global warming potential (GWP for a portfolio of 10 multi-family residences in the U.S. We argue that prior LCA studies of buildings use an inconsistent boundary for processes to be included in the supply chain: The operational phase includes all energy use in a building, but supply chains for the production of appliances, equipment and consumables associated with activities done in the building are neglected. We correct this by starting the analysis with an explicit definition of a functional unit, providing climate controlled space, and including processes associated with this functional unit. Using a hybrid LCA approach, the CED for low, mid and high-rise multi-family residences is found to increase from 30, 34, to 39 GJ/m2, respectively. This increase is due to the need for energy-intensive structural materials such as concrete and steel in taller buildings. With our approach, the share of materials and construction of total life cycle energy doubles to 26%, compared with a 13% share that would be obtained with inconsistent system boundaries used in prior studies. We thus argue that explicit definition of functional unit leads to an increase in the contribution of supply chains to building energy life cycles.

  13. Evaluation of health factors in high-rise buildings. 1. Behaviour of some environmental factors

    Energy Technology Data Exchange (ETDEWEB)

    Moese, J.R.; Raber, J.; Grill, D.; Koeck, M.

    1981-01-01

    None of the test series carried out with completely different parameters (summation measurements of different type for SO2, fluorine, chlorides as well as germ counts for air) have indicated that the people living on the higher floors of tower blocks are exposed to a greater burden than those living on lower floors. On the contrary, the chloride analyses and also ther germ counts made on the balconies showed that such tower blocks are exposed to dust and dirt swirling up from the streets from the second up to the sixth floor (max. pollution on the third floor). In the stairwell, the highest germ count was made on the ground floor, as was to be expected. Needless to say, these results apply only to the conditions prevailing here. Somewhat different results may be obtained in other places, under different conditions regarding location and building structure. However, the results clearly show that the assumption that the upper storeys of high-rise buildings are exposed to a higher burden cannot be generally valid with respect to the parameters used. This is the least that our results indicate.

  14. Optimal design of high-rise buildings with respect to fundamental eigenfrequency

    Science.gov (United States)

    Alavi, Arsalan; Rahgozar, Reza; Torkzadeh, Peyman; Hajabasi, Mohamad Ali

    2017-12-01

    In modern tall and slender structures, dynamic responses are usually the dominant design requirements, instead of strength criteria. Resonance is often a threatening phenomenon for such structures. To avoid this problem, the fundamental eigenfrequency, an eigenfrequency of higher order, should be maximized. An optimization problem with this objective is constructed in this paper and is applied to a high-rise building. Using variational method, the objective function is maximized, contributing to a particular profile for the first mode shape. Based on this preselected profile, a parametric formulation for flexural stiffness is calculated. Due to some near-zero values for stiffness, the obtained formulation will be modified by adding a lower bound constraint. To handle this constraint some new parameters are introduced; thereby allowing for construction of a model relating the unknown parameters. Based on this mathematical model, a design algorithmic procedure is presented. For the sake of convenience, a single-input design graph is presented as well. The main merit of the proposed method, compared to previous researches, is its hand calculation aspect, suitable for parametric studies and sensitivity analysis. As the presented formulations are dimensionless, they are applicable in any dimensional system. Accuracy and practicality of the proposed method is illustrated at the end by applying it to a real-life structure.

  15. Effect of Soft Story on Structural Response of High Rise Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Hejazi, F; Jilani, S; Noorzaei, J; Chieng, C Y; Jaafar, M S; Ali, A A Abang, E-mail: jamal@eng.upm.edu.my [Department of Civil, Engineering faculty, University Putra Malaysia, 43300 Serdang, Selangor (Malaysia)

    2011-02-15

    Severe structural damage suffered by several modern buildings during recent earthquakes illustrates the importance of avoiding sudden changes in lateral stiffness and strength. Recent earthquakes that occurred have shown that a large number of existing reinforced concrete buildings are vulnerable to damage or even collapse during a strong earthquake. While damage and collapse due to soft story are most often observed in buildings, they can also be developed in other types of structures. The lower level containing the concrete columns behaved as a soft story in that the columns were unable to provide adequate shear resistance during the earthquake. Usually the most economical way of retrofitting such as a building is by adding proper bracing to soft stories. So, in this paper occurring of soft at the lower level of high rise buildings subjected to earthquake has been studied. Also has been tired to investigate on adding of bracing in various arrangements to structure in order to reduce soft story effect on seismic response of building. It is lead to assess the vulnerability level of existing multi-storied buildings so that they can be retrofitted to possess the minimum requirements. This will help in minimizing the impending damages and catastrophes.

  16. Pressure integration technique for predicting wind-induced response in high-rise buildings

    Directory of Open Access Journals (Sweden)

    Aly Mousaad Aly

    2013-12-01

    Full Text Available This paper presents a procedure for response prediction in high-rise buildings under wind loads. The procedure is illustrated in an application example of a tall building exposed to both cross-wind and along-wind loads. The responses of the building in the lateral directions combined with torsion are estimated simultaneously. Results show good agreement with recent design standards; however, the proposed procedure has the advantages of accounting for complex mode shapes, non-uniform mass distribution, and interference effects from the surrounding. In addition, the technique allows for the contribution of higher modes. For accurate estimation of the acceleration response, it is important to consider not only the first two lateral vibrational modes, but also higher modes. Ignoring the contribution of higher modes may lead to underestimation of the acceleration response; on the other hand, it could result in overestimation of the displacement response. Furthermore, the procedure presented in this study can help decision makers, involved in a tall building design/retrofit to choose among innovative solutions like aerodynamic mitigation, structural member size adjustment, damping enhancement, and/or materials change, with an objective to improve the resiliency and the serviceability under extreme wind actions.

  17. Dynamics and Control of High-Rise Buildings under Multidirectional Wind Loads

    Directory of Open Access Journals (Sweden)

    Aly Mousaad Aly

    2011-01-01

    Full Text Available This paper presents a procedure for the response prediction and reduction in high-rise buildings under multidirectional wind loads. The procedure is applied to a very slender tall building that is instructive. The structure is exposed to both cross-wind and along-wind loads obtained from pressure measurements on a rigid model (scaled 1 : 100 that was tested in a wind tunnel with two different configurations of the surroundings. In the theoretical formulation, dynamic equations of the structure are introduced by finite element and 3D lumped mass modeling. The lateral responses of the building in the two directions are controlled at the same time using tuned mass dampers (TMDs and active tuned mass dampers (ATMDs commanded by LQR and fuzzy logic controllers, while the effects of the uncontrolled torsional response of the structure are simultaneously considered. Besides their simplicity, fuzzy logic controllers showed similar trend as LQR controllers under multidirectional wind loads. Nevertheless, the procedure presented in this study can help decision makers, involved in the design process, to choose among innovative solutions like structural control, different damping techniques, modifying geometry, or even changing materials.

  18. MODELING OF BLAST EFFECTS ON KEY STRUCTURAL ELEMENTS OF HIGH-RISE BUILDINGS

    Directory of Open Access Journals (Sweden)

    Agafonova Vera Valer'evna

    2012-10-01

    Full Text Available In view of persistent threats of terrorist attacks, protection of high-rise and unique buildings and structures from the above impacts remains one of the top-priority objectives of safety and security assurance projects. The author provides an overview of blast effects on a reinforced concrete column simulated through the employment of ANSYS software package. Possible patterns of the effects are considered. The semulation is performed in three sequent stages. At Stage 1, the initial stress-strain state of the column is simulated. At Stage 2, non-stationary gas dynamics of the explosion of 50 kg of TNT and the stress-strain state of the column are simulated. At Stage 3, destruction of the column, damaged by the explosion, is analyzed. The time period of complete destruction of the column after the explosion is ~ 100 ms. Numerical simulation of the environment by LS-DYNA software system assures accurate calculations; therefore, this software programme may be used to develop reliable actions aimed at reduction of effects of the explosion in order to prevent the progressive collapse.

  19. Indoor climate and thermal comfort in high-rise public housing in an equatorial climate: A field-study in Singapore

    Science.gov (United States)

    de Dear, R. J.; Leow, K. G.

    Urban residential development in Singapore has been focussed on clusters of high-rise public housing known locally as 'new towns'. Indoor climatic conditions were assessed in a sample of 214 flats in the new towns. Also a sample of 583 occupants were interviewed about their experiences of thermal comfort. Separate body-environment heat-balances were estimated for each respondent and these data were input to the PMV (ISO 7730) mathematical model of thermal comfort. The operative temperature actually preferred by the respondents was about 1°C cooler than the mean value of 29.6°C recorded in their flats. However, their empirically derived temperature preference was about 2°C warmer than the value predicted by the PMV model and ISO standard. Processes of physiological acclimatization and perceptual habituation are put forward as possible explanations for the discrepancy between temperate climate comfort theory and actual human response in the tropics. The implications for energy conservation in tropical cities are also discussed.

  20. Effect of turning frequency and season on composting materials from swine high-rise facilities.

    Science.gov (United States)

    Cook, K L; Ritchey, E L; Loughrin, J H; Haley, M; Sistani, K R; Bolster, C H

    2015-05-01

    Composting swine slurries has several advantages, liquid slurries are converted to solids at lower moisture, the total volume and weight of material is reduced and the stabilized product is more easily transported off-site. Despite this, swine waste is generally stored, treated and applied in its liquid form. High-rise finishing facilities (HRFF) permit liquid slurries to be converted to solids which are partially decomposed underneath the HRFF and then finished in compost windrows. The purpose of this study was to evaluate the effect of turning frequency and ambient weather conditions on biological, physical and chemical properties of composted slurry-woodchip mixtures from HRFF. Compost trials were conducted in either fall (FT) or spring (ST) and piles were turned once or three times per week or upon compost temperature reaching 65°C. Physical, chemical and microbiological characteristics were measured over the course of 112 (FT) or 143 (ST) days of composting. Total carbon, total nitrogen (N) and inorganic N decreased in all piles. Ammonium decreased while nitrate increased in all piles (including unturned), but total N losses were greatest in piles turned more frequently during the ST. Microbial populations of nitrifiers were dominated by ammonia-oxidizing archaea (3.0×10(3)-4.2×10(6)cellsg(-1) compost) but ammonia oxidizing bacteria (below detection to 6.0×10(5)cellsg(-1) compost) varied in response to turning and compost temperature; denitrifiers were present in high concentrations throughout the process. Swine HRFF materials composted well in windrows regardless of turning frequency and despite significant differences in starting materials and low initial C/N. Volume reduction, low moisture and low readily degradable organic matter suggest that the finished compost would have lower transportation costs and should provide value as a soil conditioner. Published by Elsevier Ltd.

  1. Residential Waste

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund; Fruergaard, Thilde; Matsufuji, Y.

    2011-01-01

    Residential waste comes from residential areas with multi-family and single-family housing and includes four types of waste: household waste, garden waste, bulky waste and household hazardous waste. Typical unit generation rates, material composition, chemical composition and determining factors...... are discussed in this chapter. Characterizing residential waste is faced with the problem that many residences already divert some waste away from the official collection systems, for example performing home composting of vegetable waste and garden waste, having their bundled newspaper picked up by the scouts...... twice a year or bringing their used furniture to the flea markets organized by charity clubs. Thus, much of the data available on residential waste represents collected waste and not necessarily all generated waste. The latter can only be characterized by careful studies directly at the source...

  2. Estimating the impact of labelling high quality compact fluorescent lamps on the energy consumption for lighting in the residential sector

    Energy Technology Data Exchange (ETDEWEB)

    Zissis, G.; Ruscassie, R.; Aubes, M. [LAPLACE, Universite de Toulouse (France)

    2007-07-01

    European Climate Change Programme (ECCP) identified residential lighting as an important area, which could result in cost-effective savings of 7 Mtonnes of CO{sub 2} by 2010. However, the residential lighting market is still dominated by inefficient incandescence lamps. Market research indicated that to achieve durable market transformation and to substantially increase the use of Compact Fluorescent Lamps (CFLs) in this sector, it is essential to market attractive and good quality CFLs. One of the conclusions is that after a considerable number of promotion and rebate schemes, organised by national energy agencies, energy utilities and lamp manufacturers, the number of CFLs in household remains marginal. A first reason of pouting CFLs is directly linked to the poor quality of some products that standard customer may find in the European market. One of the objectives of the project EnERLIn (Energy Efficient Residential Lighting Initiative, EIE-05-0176) supported by European Commission (SAVE program) is to establish a list of criteria that should fulfil high quality CFLs and to propose a standard testing protocol. Both criteria list and procedure should be based on scientific arguments taking into account existing technology limitations. The proposed protocol could then be used for labelling high quality products and thus set customer's mind in rest. The use of a CFL Quality Charter instead of imposing new standards has the advantage to be easier to adopt and may phase-out low quality product just by exploring end-user behaviour. The first objective of the present paper is to give a draft of the criteria and of the proposed protocol. Then we will examine the impact of marketing 'labelled' high quality CFLs by elaborating scenarios for energy consumption for lighting in residential sector. In those scenarios we propose to extrapolate market size using existing growth rates 'filtered' by end-user behaviour ('evolutional', &apos

  3. Mars reconnaissance orbiter's high resolution imaging science experiment (HiRISE)

    Science.gov (United States)

    McEwen, A.S.; Eliason, E.M.; Bergstrom, J.W.; Bridges, N.T.; Hansen, C.J.; Delamere, W.A.; Grant, J. A.; Gulick, V.C.; Herkenhoff, K. E.; Keszthelyi, L.; Kirk, R.L.; Mellon, M.T.; Squyres, S. W.; Thomas, N.; Weitz, C.M.

    2007-01-01

    The HiRISE camera features a 0.5 m diameter primary mirror, 12 m effective focal length, and a focal plane system that can acquire images containing up to 28 Gb (gigabits) of data in as little as 6 seconds. HiRISE will provide detailed images (0.25 to 1.3 m/pixel) covering ???1% of the Martian surface during the 2-year Primary Science Phase (PSP) beginning November 2006. Most images will include color data covering 20% of the potential field of view. A top priority is to acquire ???1000 stereo pairs and apply precision geometric corrections to enable topographic measurements to better than 25 cm vertical precision. We expect to return more than 12 Tb of HiRISE data during the 2-year PSP, and use pixel binning, conversion from 14 to 8 bit values, and a lossless compression system to increase coverage. HiRISE images are acquired via 14 CCD detectors, each with 2 output channels, and with multiple choices for pixel binning and number of Time Delay and Integration lines. HiRISE will support Mars exploration by locating and characterizing past, present, and future landing sites, unsuccessful landing sites, and past and potentially future rover traverses. We will investigate cratering, volcanism, tectonism, hydrology, sedimentary processes, stratigraphy, aeolian processes, mass wasting, landscape evolution, seasonal processes, climate change, spectrophotometry, glacial and periglacial processes, polar geology, and regolith properties. An Internet Web site (HiWeb) will enable anyone in the world to suggest HiRISE targets on Mars and to easily locate, view, and download HiRISE data products. Copyright 2007 by the American Geophysical Union.

  4. Thermal and Daylighting Performance of Energy-Efficient Windows in Highly Glazed Residential Buildings: Case Study in Korea

    Directory of Open Access Journals (Sweden)

    Chang Heon Cheong

    2014-10-01

    Full Text Available Cooling load in highly glazed residential building can be excessively large due to uncontrolled solar energy entering the indoor space. This study focuses on the cooling load reduction and changes in the daylighting properties via the application of a double window system (DWS with shading with various surface reflectivities in highly glazed residential buildings. Evaluation of thermal and daylighting performances is carried out using simulation tools. The reductions in cooling load and energy cost through the use of DWS are evaluated through a comparative simulation considering conventional windows: a single window and a double window. Three variables of window types, natural ventilation, and shading reflectivity are reflected in the study. According to our results, implementation of DWS reduced cooling load by 43%–61%. Electricity cost during the cooling period was reduced by a maximum of 24%. However, a shading device setting that prioritizes effective cooling load reduction can greatly decrease the daylighting factor and luminance level of indoor space. A DWS implementing shading device with highly reflective at all surfaces is appropriate option for the more comfortable thermal and visual environment, while a shading device with low reflectivity at rear of the surface can contribute an additional 4% cooling load reduction.

  5. Seismic performance of high rise hybrid structures with moment frame configuration

    Directory of Open Access Journals (Sweden)

    Saman Khalili

    2017-07-01

    Full Text Available The seismic design methods should pay special attention to the characteristics of ground motions especially in near fault. Near-field records are generally recognized by the sudden impulsive ground displacements in a short time domain in which contain large amount of kinetic energy. An important consequence of lateral displacement and story drift is the structural and non-structural damage. Many previous studies suggest that the mentioned parameters are sufficient to indicate the correlation between characteristics of the structural response and seismic risk. Framed tube system is one way to limit the movement of stories in high rise buildings. This structural system causes a similar behaviour of the whole resistant skeleton to a hollow tube, so that a significant increase is observed in lateral stiffness of the structure. In this study, the studied models are in the form of 20-story structures that are regular in plan and height. The resistant skeleton of the studied structures is designed according to the fourth edition of Standard No. 2800 as well as topics of the Iranian national building code. Based on the results obtained by conducting the nonlinear dynamic analyses, this study deals with the trend of variations in the target seismic response parameters subjected to the site-specific design spectrum according to the design provisions denoted in the Standard No. 2800. Topics and issues evaluated in this study include the lateral displacement, story drift and effect of the configuration of internal rigid frames in variation rates of the mentioned parameters. Based on the results, the maximum drift usually happened in the middle third of the structure height. Yet, the maximum response parameters of displacement and story drift were individually exposed to relative reduction and increase, regarding to replacement of the resistant skeleton from frame-tube into bundled-tube structure.

  6. Modeling Methodology of Progressive Collapse by the Example of Real High-Rise Buildings

    Directory of Open Access Journals (Sweden)

    Mariya Barabash

    2014-12-01

    Full Text Available The purpose of the research was to find out several ways to design real buildings with protective measures against progressive collapse. There are no uniform guidelines for choosing the type of finite element able to provide the necessary accuracy of the calculation model taking into account all the main factors affecting the strength and stability of the building. Therefore it is required to develop numerical methods for calculation on progressive collapse of buildings bearing structural elements in case of emergency. In addition, our task was to present a methodology that allows checking the stability of the building agains progressive collapse. By the technique nonlinear analysis on special (emergency regulations combination of loads and impacts is performed, including permanent and long-term regulatory burden and the impact of hypothetical local fractures bearing structures. This study was carried out on the high rise apartment complex with underground parking. In the empirical part of the study the main concern was to find out the reasons of progressive collapse of structures, taking into account stepwise assembly, building inspection performed rollover. Also the existing building retail and office complex “Gulliver” with public facilities and parking is considered, where computation was made on the progressive collapse of the upper slab technical floor. The calculation was carried out on plates or emergency landing helicopter crash on the floor slab. Analysis of the results leads to the following conclusions. To assess the real vitality of the building in an emergency situation, and resistance to progressive collapse it is recommended to count design taking into account physical and geometric nonlinearity and process modeling lifecycle.

  7. Radiometric Calibration of Mars HiRISE High Resolution Imagery Based on Fpga

    Science.gov (United States)

    Hou, Yifan; Geng, Xun; Xing, Shuai; Tang, Yonghe; Xu, Qing

    2016-06-01

    Due to the large data amount of HiRISE imagery, traditional radiometric calibration method is not able to meet the fast processing requirements. To solve this problem, a radiometric calibration system of HiRISE imagery based on field program gate array (FPGA) is designed. The montage gap between two channels caused by gray inconsistency is removed through histogram matching. The calibration system is composed of FPGA and DSP, which makes full use of the parallel processing ability of FPGA and fast computation as well as flexible control characteristic of DSP. Experimental results show that the designed system consumes less hardware resources and the real-time processing ability of radiometric calibration of HiRISE imagery is improved.

  8. Renovation of high-rise buildings with sophisticated energy saving; Renovatie hoogbouw met uitgekiende energiebesparing

    Energy Technology Data Exchange (ETDEWEB)

    Goddijn, E.

    2010-06-15

    Demolition or renovation? That is a choice that could turn out in favor of renovation. After all, renovation offers exquisite opportunities for energy saving. The quality of living and the social quality can also improve significantly and time is gained. One example is the Palenstein district in Zoetermeer, the Netherlands, where postwar gallery apartments are reconstructed into energy efficient residential apartments. [Dutch] Slopen of renoveren? De keuze zou wel eens vaker in het voordeel van renoveren kunnen uitpakken. Renovatie biedt immers uitgelezen kansen voor energiebesparing. Ook de woonkwaliteit en de sociale kwaliteit kunnen sterk verbeteren en het levert tijdwinst op. Een voorbeeld is de Zoetermeerse wijk Palenstein, waar naoorlogse galerijflats worden omgebouwd tot energiezuinige woonappartementen.

  9. Modular High Voltage Pulse Converter for Short Rise and Decay Times

    NARCIS (Netherlands)

    Mao, S.

    2018-01-01

    This thesis explores a modular HV pulse converter technology with short rise and decay times. A systematic methodology to derive and classify HV architectures based on a modularization level of power building blocks of the HV pulse converter is developed to summarize existing architectures and

  10. High variability of climate and surface mass balance induced by Antarctic ice rises

    NARCIS (Netherlands)

    Lenaerts, Jan; Brown, Joel; van den Broeke, Michiel; Matsuoka, Kenichi; Drews, Reinhard; Callens, Denis; Philippe, Morgane; Gorodetskaya, I.V.; van Meijgaard, E.; Tijm - Reijmer, Catharina; Pattyn, F.; van Lipzig, N.P.M.

    2014-01-01

    Ice rises play key roles in buttressing the neighbouring ice shelves and potentially provide palaeoclimate proxies from ice cores drilled near their divides. Little is known, however, about their influence on local climate and surface mass balance (SMB). Here we combine 12 years (2001–12) of

  11. Introduction to the High Resolution Imaging Science Experiment (HiRISE)

    Science.gov (United States)

    McEwen, Alfred S.; Herkenhoff, Kenneth E.; Keszthelyi, Laszlo

    2009-01-01

    HiRISE, the largest camera ever to leave Earth orbit, has opened a new chapter in the exploration of Mars. Its ability to resolve 1-m-scale objects – in color and 3 dimensions – anywhere on the surface of Mars is superior to that of unclassified orbital remote sensing data available to terrestrial geologists.

  12. RISE to the IUPUI Challenge: High Impact Practices Focused on Students' Success

    Science.gov (United States)

    Baker, Sarah S.; Fisher, Mary L.; Johnson, Kathy E.

    2012-01-01

    Civic engagement and student success have become a hallmark of Indiana University--Purdue University Indianapolis (IUPUI). In 2008 a new program supporting increased student engagement and deeper learning was implemented, the RISE (Research, International Study, Service Learning, and Experiential Learning) to the IUPUI Challenge initiative…

  13. Multicriteria Decision Analysis of Material Selection of High Energy Performance Residential Building

    Science.gov (United States)

    Čuláková, Monika; Vilčeková, Silvia; Katunská, Jana; Krídlová Burdová, Eva

    2013-11-01

    In world with limited amount of energy sources and with serious environmental pollution, interest in comparing the environmental embodied impacts of buildings using different structure systems and alternative building materials will be increased. This paper shows the significance of life cycle energy and carbon perspective and the material selection in reducing energy consumption and emissions production in the built environment. The study evaluates embodied environmental impacts of nearly zero energy residential structures. The environmental assessment uses framework of LCA within boundary: cradle to gate. Designed alternative scenarios of material compositions are also assessed in terms of energy effectiveness through selected thermal-physical parameters. This study uses multi-criteria decision analysis for making clearer selection between alternative scenarios. The results of MCDA show that alternative E from materials on nature plant base (wood, straw bales, massive wood panel) present possible way to sustainable perspective of nearly zero energy houses in Slovak republic

  14. Multidimensional Treatment Foster Care: An Alternative to Residential Treatment for High Risk Children and Adolescents

    Directory of Open Access Journals (Sweden)

    Philip A. Fisher

    2012-07-01

    Full Text Available This paper describes the Multidimensional Treatment Foster Care program (MTFC, an evidence based approach for providing psychotherapeutic treatment for very troubled children and adolescents that is an alternative to residential care. Versions of the MTFC program have been developed and validated for young children with a history of maltreatment as well as for older children and adolescents who are involved with the youth justice system. In the paper we describe the development of the MTFC program and its foundations in the social learning model that originated at the Oregon Social Learning Center in the 1960's and 70's. We present information about program elements. We then review the research that has been conducted on MTFC.

  15. A comparison of RANS computations and wind tunnel tests for RMS pressures on a high-rise building model

    NARCIS (Netherlands)

    Kalkman, I.M.; Bronkhorst, A.J.; Bentum, C.A. van; Franke, J.

    2012-01-01

    Five root-mean-square (RMS) pressure models are used in combination with different turbulence models to determine whether it is possible to obtain a conservative estimate of RMS pressures on a high-rise building model from a RANS calculation. When a precursor domain is used for the generation of

  16. Wind interference between two high-rise building models: On the influence of shielding, channeling and buffeting on peak pressures

    NARCIS (Netherlands)

    Bronkhorst, A.J.; Geurts, C.P.W.; Bentum, C.A. van; Blocken, B.

    2014-01-01

    The influence of interference between two high-rise building models on the minimum peak pressures was investigated in an atmospheric boundary layer wind tunnel. Pressure measur€ments were performed on a square model with an aspect ratio of 1 to 4. The influence of an interfering model with the same

  17. Evaluation of Stiffness Changes in a High-Rise Building by Measurements of Lateral Displacements Using GPS Technology

    Directory of Open Access Journals (Sweden)

    Se Woon Choi

    2013-11-01

    Full Text Available The outrigger truss system is one of the most frequently used lateral load resisting structural systems. However, little research has been reported on the effect of installation of outrigger trusses on improvement of lateral stiffness of a high-rise building through full-scale measurements. In this paper, stiffness changes of a high-rise building due to installation of outrigger trusses have been evaluated by measuring lateral displacements using a global positioning system (GPS. To confirm the error range of the GPS measurement system used in the full-scale measurement tests, the GPS displacement monitoring system is investigated through a free vibration test of the experimental model. Then, for the evaluation of lateral stiffness of a high-rise building under construction, the GPS displacement monitoring system is applied to measurements of lateral displacements of a 66-story high-rise building before and after installation of outrigger truss. The stiffness improvement of the building before and after the installation is confirmed through the changes of the natural frequencies and the ratios of the base shear forces to the roof displacements.

  18. Waste water ducts in high-rise buildings. Pressure compensation in the downpipe; Schmutzwasserleitungen in Hochhaeusern. Druckausgleich im Fallrohr

    Energy Technology Data Exchange (ETDEWEB)

    Ishorst, B. [Informationszentrum Entwaesserungstechnik Guss e.V. (IZEG) (Germany); Guetegemeinschaft Entwaesserungstechnik Guss e.V. (GEG) (Germany)

    2006-09-15

    Ventilation is a key aspect for correct function of a waste water system. In order to enable pressure compensation and ensure that sewer gases are led outside, downpipes in high-rise buildings must have at least one main ventilation duct. The author presents examples to illustrate how downpipes should be constructed for optimum flow conditions and reliable function. (orig.)

  19. A comparison of peak pressure interference factors interference factors for high-rise buildings determined in two ABL wind tunnels

    NARCIS (Netherlands)

    Bronkhorst, A.J.; Uffelen, M. van; Geurts, C.P.W.; Aanen, L.; Bentum, C.A. van

    2013-01-01

    Pressure measurements were performed on various configurations of two high-rise building models in two atmospheric boundary layer wind tunnels in the Netherlands. A comparison was made of the interference factors of the minimum and maximum peak pressures over all pressure taps at 0 degree angle of

  20. Effects of soil-structure in high-rise buildings by means of dimensionless analysis and a simplified model

    NARCIS (Netherlands)

    Gómez, S.S.; Pruiksma, J.

    2017-01-01

    In this paper simplified expressions for assessing fundamental frequency and modal damping of high-rise buildings taking into account the soil-structure interaction (SSI) are proposed. To this end, several steps have been followed. First, a 3DoF model is formulated making use of dimensionless

  1. Preconditioning and Formation Mechanisms of Maud Rise (Open Ocean) Polynyas in a High-Resolution CESM Simulation

    Science.gov (United States)

    Kurtakoti, P. K.; Veneziani, C.; Stoessel, A.; Weijer, W.

    2016-12-01

    Processes responsible for preconditioning and formation of Maud Rise Polynyas (MRP) were analyzed within the framework of a high-resolution fully coupled Community Earth System Model (CESM) simulation. Open Ocean Polynyas (OOPs) are large ice-free areas within the winter ice pack. These are regions of deep convection and strong atmosphere-ice-ocean interaction through which they play an important role in the formation of bottom waters. The data analyzed comes from a simulation conducted in a pre-industrial scenario as part of the Accelerated Climate Modeling for Energy (ACME) project. Within this simulation, persistent winter OOPs were simulated in the Weddell Sea (Weddell Sea Polynya) and over the Maud Rise seamount (Maud Rise Polynya). The sea ice concentration in the Weddell Sea shows that MRP acts as a precondition to Weddell Sea polynyas, which is consistent with mid 1970s observations of a westward expansion of MRP into the Weddell Sea. The OOPs in years 30-40 of the CESM simulation are largely over Maud Rise giving us an opportunity to investigate processes that trigger and maintain the OOP in winter over Maud Rise. The heat content of the Weddell Deep Water (WDW) is seen to be an important factor for MRPs, consistent with previous studies. The first MRP in the 30s coincides with the strongest negative wind stress curl over the Weddell Sea, which implies that this condition is a triggering mechanism for deep convection. The deep convective event associated with the OOP leads to a reduction of deep ocean heat reservoir up to 3000m depth. The simulation captures a westward flow of WDW impinging on Maud Rise seamount. Previous studies suggest Taylor column dynamics to be necessary for MRPs to emerge. We have explored how Taylor column dynamics could contribute to preconditioning and triggering deep open ocean convection over Maud Rise Seamount. We also investigate the importance of resolution of bottom topography for the formation of a strong enough Taylor

  2. The Relationship Between Spatial Configuration and Social Interaction in High-Rise Flats: A Case Study On The Jatinegara Barat in Jakarta.

    OpenAIRE

    Ridwana Rifan; Prayitno Budi; Utomo Hatmoko Adi

    2018-01-01

    The construction of high-rise flats to minimize urban slum areas in Indonesia still create space use behavior problems for its residents due to the changes of space configuration between high-rise landed housing. Conventional high-rise flats cannot well accommodate the needs of social interactions happened in landed housing because of its spatial limitation that leads to uncertainty of space use behavior settings. This study aims to understand the relationship between spatial configuration on...

  3. Moving Home: Examining the Independent Effects of Individual- and Neighborhood-Level Residential Mobility on Recidivism in High-Risk Parolees.

    Science.gov (United States)

    Breetzke, Gregory; Polaschek, Devon

    2017-10-01

    A number of studies have shown that the residential mobility of an offender postrelease can significantly influence recidivism. Research has also shown how the mobility of neighborhoods into which offenders are released is an important contextual factor that predicts recidivism. Within the social disorganization framework, this study combines these lines of research by examining the effect of both individual- and neighborhood-level residential mobility on recidivism for a cohort of high-risk prisoners released on parole in New Zealand. Using multilevel analysis techniques, we found that neither immediate individual-level residential mobility nor neighborhood-level mobility was associated with recidivism after controlling for various multilevel predictors. A number of individual- and neighborhood-level variables were predictive of recidivism, including the number of parole conditions placed on the released offender, and the percent foreign born in their neighborhood. These results are discussed within the context of an increasingly eclectic and diverse country.

  4. OFFER SOLUTIONS FOR THE DEVELOPMENT OF PROJECTS OF ENERGY-EFFICIENT HIGH-RISE BUILDINGS IN UKRAINE

    Directory of Open Access Journals (Sweden)

    DYACHENKO L. Yu.

    2016-04-01

    Full Text Available Raising of problem. Today, the question of ecology is in the first place all over the world. Our homes are not just destroying nature, but also need a lot of energy. 40% of the world's energy goes to lighting, air conditioning, heating, etc. Ukraine is a country, in which there are many cities with large industrial zones. By introducing a number of innovations for increasing energy efficiency we can improve the ecological situation in the country. The purpose of the article is offer solutions for the development of projects of energy-efficient high-rise buildings in Ukraine. Conclusion. Proposed solutions for the development of projects of energy-efficient high-rise buildings in Ukraine will allow to solve the problems: ecology, energy saving, saving of natural resources in the country in the near future.

  5. Simulation of the Wind Effect on an Ensemble of High-Rise Buildings by means of Multiblock Computational Technologies

    Science.gov (United States)

    Isaev, S. A.; Baranov, P. A.; Zhukova, Yu. V.; Tereshkin, A. A.; Usachov, A. E.

    2014-01-01

    The numerical simulation of the wind effect on an ensemble of high-rise buildings is based on the solution of Reynolds-averaged Navier-Stokes equations closed with the help of a shear stress transfer model modified with account for the influence of the curvature of streamlines with the use of multiblock computational technologies in the VP2/3 package. It has been shown that the nonstationary aerodynamics of construction ensembles of closely spaced high-rise buildings has the characteristic features inherent in tandems of blunt bodies, and the pulsating loads in the lee buildings are largely determined by the self-organization of the jet-vortex structures in the space between buildings.

  6. Air conditioning in high rise buildings; Conditionnement d'air dans les immeubles de grande hauteur

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-07-01

    This two-tomes book brings together the 108 presentations given at the first conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: general design and control systems, including split systems, radiant panels, fluctuating and gravity ventilation etc..; energy consumption, optimization and heat recovery; cold storage for peak shaving, including ice slurry circulation; indoor air quality; fire and smokes protection, protection against chimney effects and lighting spots; use of fuzzy logic and of neural networks. It includes also a description of the high rise building situation and works in progress in China, Japan and in some other countries. (J.S.)

  7. Design and Optimization of Slot Aluminum Alloy Connectors of Photovoltaics Applied to High-rise Building Facades

    Science.gov (United States)

    Liang, Ya-Wei; Zhang, Hong-Mei; Dong, Jin-Zhi; Shi, Zhen-Hua

    2016-05-01

    Building Integrated Photovoltaic (BIPV) is a resort to save energy and reduce heat gain of buildings, utilize new and renewable energy, solve environment problems and alleviate electricity shortage in large cities. The area needed to generate power makes facade integrated photovoltaic panel a superb choice, especially in high-rise buildings. Numerous scholars have hitherto explored Building Facade Integrated Photovoltaic, however, focusing mainly on thermal performance, which fails to ensure seismic safety of high-rise buildings integrated photovoltaic. Based on connecting forms of the glass curtain wall, a connector jointing photovoltaic panel and facade was designed, which underwent loading position and size optimization. Static loading scenarios were conducted to test and verify the connector's mechanical properties under gravity and wind loading by means of HyperWorks. Compared to the unoptimized design, the optimized one saved material and managed to reduce maximum deflection by 74.64%.

  8. Cost-Effectiveness Analysis of the 2009 and 2012 IECC Residential Provisions – Technical Support Document

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V.; Lucas, Robert G.; Goel, Supriya

    2012-12-04

    This analysis was conducted by Pacific Northwest National Laboratory (PNNL) in support of the U.S. Department of Energy’s (DOE) Building Energy Codes Program (BECP). DOE supports the development and adoption of efficient residential and commercial building energy codes. These codes set the minimum requirements for energy efficient building design and construction and ensure energy savings on a national level. This analysis focuses on one and two family dwellings, townhomes, and low-rise multifamily residential buildings. For these buildings, the basis of the energy codes is the International Energy Conservation Code (IECC). This report does not address commercial and high-rise residential buildings, which reference ANSI/ASHRAE/IES Standard 90.1.

  9. On the Design of High-Rise Buildings for Multihazard: Fundamental Differences between Wind and Earthquake Demand

    Directory of Open Access Journals (Sweden)

    Aly Mousaad Aly

    2015-01-01

    Full Text Available In the past few decades, high-rise buildings have received a renewed interest in many city business locations, where land is scarce, as per their economics, sustainability, and other benefits. Taller and taller towers are being built everywhere in the world. However, the increased frequency of multihazard disasters makes it challenging to balance between a resilient and sustainable construction. Accordingly, it is essential to understand the behavior of such structures under multihazard loadings, in order to apply such knowledge to design. The results obtained from the dynamic analysis of two different high-rise buildings (54-story and 76-story buildings investigated in the current study indicate that earthquake loads excite higher modes that produce lower interstory drift, compared to wind loads, but higher accelerations that occur for a shorter time. Wind-induced accelerations may have comfort and serviceability concerns, while excessive interstory drifts can cause security issues. The results also show that high-rise and slender buildings designed for wind may be safe under moderate earthquake loads, regarding the main force resisting system. Nevertheless, nonstructural components may present a significant percentage of loss exposure of buildings to earthquakes due to higher floor acceleration. Consequently, appropriate damping/control techniques for tall buildings are recommended for mitigation under multihazard.

  10. Delays in the EMS response to and the evacuation of patients in high-rise buildings in Singapore.

    Science.gov (United States)

    Lateef, F; Anantharaman, V

    2000-01-01

    Singapore is a highly urbanized and cosmopolitan city situated at the crossroads of Southeast Asia. High-rise buildings and "vertical living" are common, and the city serves as a major business, financial, and industrial hub in the region. More than 80% of the population live in high-rise apartments. This poses unique problems and challenges for emergency ambulance services personnel in the access to and evacuation of patients. To estimate the arrival-to-patient contact delay when accessing patients in high-rise buildings and evacuating them to the hospital, compared with accessing patients in ground-level premises. This was a prospective study carried out from February 2 to March 1, 1998, for emergency calls from two of the busiest fire stations. The first 150 consecutive cases were enrolled into each of the two groups. Cases of road traffic accidents were excluded because these did not require the crew to get into a building. The times were clocked by one of the paramedics, using a stopwatch. A high-rise building was defined as one where the crew had to ascend at least one flight of stairs. A ground-level building did not involve any stair climbing. We set forth to determine whether the interval between the following was statistically significant when comparing high-rise vs ground-level premises: 1) time when the ambulance arrives at the scene (taken as the time when the driver turns the engine off) and time of arrival at the patient's side; 2) time of leaving the dwelling with the patient and time when the ambulance starts its journey to the hospital (taken as the time when the driver starts the engine). Data analysis was done with the use of SPSS, and the one-tailed unpaired Student's t-test was used for significance testing, with the alpha error rate set at 0.05. Results. One hundred fifty runs were analyzed for each group. The mean delay from arrival to patient contact was 2.49 +/- 0.98 minutes for the high-rise group compared with 1.02 +/- 1.41 minutes for

  11. Understanding Residential Polarization in a Globalizing City

    Directory of Open Access Journals (Sweden)

    Ibrahim Rotimi Aliu

    2013-12-01

    Full Text Available This study examines the spatial polarization that characterizes the dwellings in the African leading megacity of Lagos. Data were collected through an extensive housing survey carried out on 1,485 household residences in 56 wards within 12 administrative units in Lagos megacity. The spatial dimension of residential density in the city generates three unique residential patterns which are low residential density (LRD, medium residential density (MRD, and high residential density (HRD areas. Descriptive and multivariate inferential statistics were used to render explanations for the spatial variations in the residential quality variables in the study area. Findings indicated that a clear difference exists in the residential quality within the three residential density areas of Lagos. High correlations exist among the residential quality indicators and housing type. The principal component analysis shows that residential polarizations that occur in the LRD, MRD, and HRD are based on the location, dwelling facility, interior and exterior quality, neighborhood integrity, social bond, barrier to entry, and security. The practical implications of residential polarizations along the residential density areas are explicitly expressed.

  12. Rapid high-temperature metamorphism of East Pacific Rise gabbros from Hess Deep

    Science.gov (United States)

    Manning, Craig E.; Weston, Patricia E.; Mahon, Keith I.

    1996-10-01

    Metamorphosed oceanic gabbros provide a record of the cooling history of the lower crust near mid-ocean ridges, but the temperature range, rate, and location of subsolidus events are poorly known. We combine hornblende-plagioclase thermometry, statistical analysis, and thermal models to estimate precisely the temperature, time, distance from axis, and duration of metamorphism in East Pacific Rise gabbros from Hess Deep, ODP Hole 894G. Metamorphic hornblende and plagioclase, which formed during microfracturing and sea water penetration, equilibrated at a mean temperature of 716 ± 8°C (90% confidence level). Comparison of the properties of the observed temperature distribution with those of model events indicates that metamorphism spanned ≤ 60°C. When combined with thermal models of fast-spreading centers, this implies that metamorphism was rapid (≤ 6000 yr) and occurred 1-4 km off axis. Application of this approach to other gabbros will allow comparison of spatial and temporal characteristics of deformation and fluid flow in the lower oceanic crust as a function of ridge setting.

  13. A highly unradiogenic lead isotopic signature revealed by volcanic rocks from the East Pacific Rise.

    Science.gov (United States)

    Mougel, Berengere; Agranier, Arnaud; Hemond, Christophe; Gente, Pascal

    2014-07-16

    Radiogenic isotopes in oceanic basalts provide a window into the different geochemical components defining the composition of Earth's mantle. Here we report the discovery of a novel geochemical signature in volcanic glasses sampled at a sub-kilometre scale along the East Pacific Rise between 15°37'N and 15°47'N. The most striking aspect of this signature is its unradiogenic lead ((206)Pb/(204)Pb=17.49, (207)Pb/(204)Pb=15.46 and (208)Pb/(204)Pb=36.83). In conjunction with enriched Sr, Nd and Hf signatures, Pb isotopes depict mixing lines that trend away from any known mantle end-members. We suggest that this unradiogenic lead component sampled by magmatic melts corresponds to a novel upper mantle reservoir that should be considered in the Pb isotope budget of the bulk silicate Earth. Major, trace element and isotope compositions are suggestive of an ancient and lower continental origin for this unradiogenic lead component, possibly sulphide-bearing pyroxenites that were preserved even after prolonged stirring within the ambient upper mantle.

  14. Air conditioning in high rise buildings; conditionnement d'air dans les immeubles de grande hauteur

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    This book brings together the 103 presentations given at the 2. conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: design of air conditioning equipment for high buildings; air quality and thermal comfort inside these buildings; constraints and possible improvements of the refrigeration equipment used; energy conservation; fire protection and smokes detection. All themes are presented both on the technical and economical points of view and concern more particularly the buildings of Chinese cities. This publication is available both on the book and CD-Rom forms. (J.S.)

  15. New facades for two high-rise buildings in Zurich; Neu eingekleidet. Zwei Wohntuerme in Zuerich werden mit Solarmodulen neu eingekleidet

    Energy Technology Data Exchange (ETDEWEB)

    Beneking, Andreas

    2012-09-15

    Two high-rise apartment buildings in Switzerland, originally constructed in the seventies of last century, were modernized with an integrated solar facade. The cost was kept at acceptable level in spite of the problems encountered. The project may be a model project for other buildings of this era as there is vast potential in the external walls of high-rise buildings.

  16. RE-USABILITY OF HIGH-RISE BUILDINGS: A CASE STUDY OF THE ARTS TOWER IN SHEFFIELD, UNITED KINGDOM

    Directory of Open Access Journals (Sweden)

    Ali M S Kashkooli

    2010-03-01

    Full Text Available Undoubtedly the high-rise buildings are phenomena of the new high-tech life style and a symbol of development, power and technology. Today, society is changing at such speed that buildings are faced with new demands where they need to be in a position to adapt the change. There are times when buildings change function during construction or even during the design process, and one of the necessities today is the re-usability of buildings, which would also help to increase their service life. The main aim of this paper is to identify some of the key areas in designing structure of high-rise buildings in order to allow the possibilities for future functional changes by illustrating an ideal framework for general structure of these giants. The paper also reveals an example of a case study building, in which these principles have been considered during its redesign, showing samples of master student projects with an aim to assign new function that considers a new concept of re-usability as a concretive structural design. The study is based on a qualitative method and the data is collected by site visits, with preparation of plans, sections, site photos and information using the internet, and through the use of appropriate literature review of high-rise buildings and their re-usability. The results highlighted a necessity for developing a concept of re-usability in designing of new buildings for future in order to prevent financial losses, also the waste of energy and time in respect of changes in construction, design and the negative environmental impact of demolition. This in turn leads us to get closer look into the concept of ‘Sustainable Development.’

  17. The importance of testing to evaluate the effect masonry walls have on high-rise building stiffness

    Energy Technology Data Exchange (ETDEWEB)

    Weinstein, J.S.; Hostetler, W.A.

    1999-07-01

    A structural investigation was undertaken to evaluate the stiffening effect that unreinforced masonry core walls have on an existing high-rise building. Numerous unknowns about the masonry walls made it difficult to meaningfully apply to the study information available in the literature about typical masonry construction and strengths. A testing program, which consisted of an on-site investigation, in-place tests on representative masonry walls, and laboratory tests on representative masonry units and mortar joints, was implemented to evaluate the masonry directly. In conjunction with structural analysis, the testing program played a crucial role in determining that the masonry walls do indeed add substantial stiffness to the building.

  18. Research of the Interaction of Piles with Different Lengths and the Grillage in the Foundations of High-Rise Buildings

    Science.gov (United States)

    Pidlutskyi, Vasyl; Boyko, Igor; Nosenko, Viktor

    2017-09-01

    The interaction of piles with different lengths and the grillage in the foundations of high-rise buildings is considered. The numerical modeling of the «base - foundation - superstructure» system is performed. The redistribution of the efforts in piles depending on the sizes of a foundation slab and the parameters of piles (length and location) is investigated. Typical zones of a foundation such as central, lateral, and angular ones are separated. The redistribution of efforts between piles and a grillage is revealed.

  19. Research of the Interaction of Piles with Different Lengths and the Grillage in the Foundations of High-Rise Buildings

    Directory of Open Access Journals (Sweden)

    Pidlutskyi Vasyl

    2017-09-01

    Full Text Available The interaction of piles with different lengths and the grillage in the foundations of high-rise buildings is considered. The numerical modeling of the «base - foundation - superstructure» system is performed. The redistribution of the efforts in piles depending on the sizes of a foundation slab and the parameters of piles (length and location is investigated. Typical zones of a foundation such as central, lateral, and angular ones are separated. The redistribution of efforts between piles and a grillage is revealed.

  20. An explanation for the rise in Tc in the Tl- and Bi-based high temperature superconductors

    Science.gov (United States)

    Bose, S. M.; Longe, P.

    1991-01-01

    Using the plasmon exchange model for the high T(sub c) superconductor, it is shown that the T(sub c) rises with an increase in the number of CuO layers per unit cell, which is in agreement with recent observations in the Tl- and Bi-based compounds. The calculation also suggests that the sample will become superconducting in successive stages and that there is a saturation effect, i.e., that T(sub c) cannot be raised indefinitely by increasing the number of CuO layers.

  1. An explanation for the rise in T(sub c) in the Tl- and Bi-based high temperature superconductors

    Science.gov (United States)

    Bose, S. M.; Longe, P.

    1990-01-01

    Using the plasmon exchange model for the high T(sub c) superconductor, it is shown that the T(sub c) rises with an increase in the number of CuO layers per unit cell, which is in agreement with recent observations in the Tl- and Bi-based compounds. The calculation also suggests that the sample will become superconducting in successive stages and that there is a saturation effect, i.e., that T(sub c) cannot be raised indefinitely by increasing the number of CuO layers.

  2. Reduction of Solar UV Radiation Due to Urban High-Rise Buildings--A Coupled Modelling Study.

    Directory of Open Access Journals (Sweden)

    Ka-Ming Wai

    Full Text Available Solar UV radiation has both adverse and beneficial effects to human health. Using models (a radiative transfer model coupled to a building shading model, together with satellite and surface measurements, we studied the un-obstructed and obstructed UV environments in a sub-tropical urban environment featured with relatively high pollution (aerosol loadings and high-rise buildings. Seasonal patterns of the erythemal UV exposure rates were governed by solar zenith angles, seasonal variations of aerosol loadings and cloud effects. The radiative transfer modelling results agreed with measurements of erythemal UV exposure rates and spectral irradiances in UVA and UVB ranges. High-rise buildings and narrow road width (height to width, H/W, ratios up to 15 reduced the modelled total UV (UVA+UVB radiation and leave 10% of the un-obstructed exposure rate at ground-level at noon. No more than 80% of the un-obstructed exposure rate was received in the open area surrounded by 20-storey buildings. Our modelled reduction of UVB radiation in the urban environment was consistent with similar measurements obtained for Australia. However, our results in more extreme environments (higher H/W ratios were for the first time reported, with 18% of the un-obstructed exposure rate remained at the ground-level center of the street canyon.

  3. Reduction of Solar UV Radiation Due to Urban High-Rise Buildings – A Coupled Modelling Study

    Science.gov (United States)

    Wai, Ka-Ming; Yu, Peter K. N.; Lam, Ka-Se

    2015-01-01

    Solar UV radiation has both adverse and beneficial effects to human health. Using models (a radiative transfer model coupled to a building shading model), together with satellite and surface measurements, we studied the un-obstructed and obstructed UV environments in a sub-tropical urban environment featured with relatively high pollution (aerosol) loadings and high-rise buildings. Seasonal patterns of the erythemal UV exposure rates were governed by solar zenith angles, seasonal variations of aerosol loadings and cloud effects. The radiative transfer modelling results agreed with measurements of erythemal UV exposure rates and spectral irradiances in UVA and UVB ranges. High-rise buildings and narrow road width (height to width, H/W, ratios up to 15) reduced the modelled total UV (UVA+UVB) radiation and leave 10% of the un-obstructed exposure rate at ground-level at noon. No more than 80% of the un-obstructed exposure rate was received in the open area surrounded by 20-storey buildings. Our modelled reduction of UVB radiation in the urban environment was consistent with similar measurements obtained for Australia. However, our results in more extreme environments (higher H/W ratios) were for the first time reported, with 18% of the un-obstructed exposure rate remained at the ground-level center of the street canyon. PMID:26263507

  4. Reduction of Solar UV Radiation Due to Urban High-Rise Buildings--A Coupled Modelling Study.

    Science.gov (United States)

    Wai, Ka-Ming; Yu, Peter K N; Lam, Ka-Se

    2015-01-01

    Solar UV radiation has both adverse and beneficial effects to human health. Using models (a radiative transfer model coupled to a building shading model), together with satellite and surface measurements, we studied the un-obstructed and obstructed UV environments in a sub-tropical urban environment featured with relatively high pollution (aerosol) loadings and high-rise buildings. Seasonal patterns of the erythemal UV exposure rates were governed by solar zenith angles, seasonal variations of aerosol loadings and cloud effects. The radiative transfer modelling results agreed with measurements of erythemal UV exposure rates and spectral irradiances in UVA and UVB ranges. High-rise buildings and narrow road width (height to width, H/W, ratios up to 15) reduced the modelled total UV (UVA+UVB) radiation and leave 10% of the un-obstructed exposure rate at ground-level at noon. No more than 80% of the un-obstructed exposure rate was received in the open area surrounded by 20-storey buildings. Our modelled reduction of UVB radiation in the urban environment was consistent with similar measurements obtained for Australia. However, our results in more extreme environments (higher H/W ratios) were for the first time reported, with 18% of the un-obstructed exposure rate remained at the ground-level center of the street canyon.

  5. THE CHANGE IN DEFORMATION CHARACTERISTICS OF CONCRETE MONOLITHIC HIGH-RISE BUILDINGS

    Directory of Open Access Journals (Sweden)

    V. V. Punahin

    2009-03-01

    Full Text Available In the article results of studies of deformation features of concrete on actuate cement for monolithic high-altitude buildings are presented. It is shown that in construction of the high-altitude monolithic buildings in a summer period of a year one should take into account the character of changing the concrete elasticity and plasticity in time, which differs from the same indices for the concrete of normal hardening.

  6. Contemporary facades of multistorey residential buildings in Kiev: Videoecological aspect

    Directory of Open Access Journals (Sweden)

    Kozlova Nataliia

    2016-01-01

    Full Text Available The article is devoted to one of the actual problems concerning the current state of the facades on apartment buildings in residential districts in Kiev - videoecology. The main purpose of the article is to determine the degree of visual aggressiveness of multistorey residential buildings in Kiev. It also investigates the problem of finding the optimal criteria for creating an ecologically healthy and friendly inhabited environment in the capital city of Ukraine. The modern visual environment in the capital is contaminated, not only because of the increasing numbers of promotional billboards, but also because of the contemporary architecture of high-rise buildings such as office buildings, apartment buildings. Their composition is usually based on a simple description of a rhythm. There are also repetitions of the end parts of buildings in “lowercase” buildings, which are high-rise buildings that alternate with nine or identical apartment groups. It creates a sense of oppressive monotony and leads to psychological and visual fatigue, especially when these repetitions are the only pattern the eye perceives. In the article a theoretical block of ecological-aesthetic criteria is defined, which must be met by the modern architecture facades of multistorey residential houses in Kiev.

  7. Urban renewal based wind environment at pedestrian level in high-density and high-rise urban areas in Sai Ying Pun, Hong Kong

    Science.gov (United States)

    Yao, J. W.; Zheng, J. Y.; Zhao, Y.; Shao, Y. H.; Yuan, F.

    2017-11-01

    In high-density and high-rise urban areas, pedestrian level winds contribute to improve comfort, safety and diffusion of heat in urban areas. Outdoor wind study is extremely vital and a prerequisite in high-density cities considering that the immediate pedestrian level wind environment is fundamentally impacted by the presence of a series of high-rise buildings. In this paper, the research site of Sai Ying Pun in Hong Kong will be analysed in terms of geography, climate and urban morphology, while the surrounding natural ventilation has also been simulated by the wind tunnel experiment Computational Fluid Dynamics (CFD). It has found that, the existing problems in this district are the contradiction between planning control and commercial interests, which means some areas around tall buildings are not benefit to the residents because of the unhealthy wind environment. Therefore, some recommendation of urban renewal strategy has been provided.

  8. Low power, high voltage power supply with fast rise/fall time

    Science.gov (United States)

    Bearden, Douglas B. (Inventor)

    2007-01-01

    A low power, high voltage power supply system includes a high voltage power supply stage and a preregulator for programming the power supply stage so as to produce an output voltage which is a predetermined fraction of a desired voltage level. The power supply stage includes a high voltage, voltage doubler stage connected to receive the output voltage from the preregulator and for, when activated, providing amplification of the output voltage to the desired voltage level. A first feedback loop is connected between the output of the preregulator and an input of the preregulator while a second feedback loop is connected between the output of the power supply stage and the input of the preregulator.

  9. LSD. Its rise, fall, and renewed popularity among high school students.

    Science.gov (United States)

    Schwartz, R H

    1995-04-01

    LSD is making a comeback nationwide among Caucasian middle-class high school and college students. Compared to the mean values during the years 1985 to 1990, an approximately 25% increase occurred in lifetime-, annual-, and monthly-use rates of LSD, in 1993, according to the annual NIDA high school senior survey. In 1992, an increase in LSD-related arrests occurred, as did seizures of larger quantities of consumer-ready LSD. The number of LSD-related emergency room visits by adolescents increased, and intermittent LSD-related violent behavior, including suicide, homicide, and accidental death, were higher than in the previous 5-year period. Fewer high school students attribute great danger in trying LSD once or twice. The painfully learned lessons about LSD seem, sadly, destined to be relearned by the youth of the 1990s.

  10. Subsurface geothermal energy utilisation in high-rise buildings; Oberflaechennahe Geothermie: Nutzung im Hochhausbau

    Energy Technology Data Exchange (ETDEWEB)

    Thaher, M. [ELE Erdbaulaboratorium Essen Ingenieurgesellschaft fuer Geotechnik mbH/ELE Frankfurt/Rhein-Main, Weiterstadt (Germany); Bialon, E. [ABG Allgemeine Baubetreuungsgesellschaft mbH, Koeln (Germany); Berchtold, P. [PB Ing.-Buero fuer Energie und Haustechnik, Sarnen (Switzerland)

    2005-06-01

    Utilisation of subsurface geothermal heat is an interesting option because of its high availability and environment-friendly nature. For economic optimisation, the main geothermal and technical facility parameters must be matched optimally. This is an interdisciplinary task for the projecting engineer in all phases of projecting, implementation, and operation. (orig.)

  11. Acceleration of fibrinolysis by high-frequency ultrasound: The contribution of acoustic streaming and temperature rise

    NARCIS (Netherlands)

    Sakharov, D.V.; Hekkenberg, R.T.; Rijken, D.C.

    2000-01-01

    High-frequency ultrasound has been shown to accelerate enzymatic fibrinolysis. One of the supposed mechanisms of this effect is the enhancement of mass transport by acoustic streaming, i.e., ultrasound-induced macroscopic flow around the clot. In this study, which is aimed at further elucidating the

  12. Modal–Physical Hybrid System Identification of High-rise Building via Subspace and Inverse-Mode Methods

    Directory of Open Access Journals (Sweden)

    Kohei Fujita

    2017-08-01

    Full Text Available A system identification (SI problem of high-rise buildings is investigated under restricted data environments. The shear and bending stiffnesses of a shear-bending model (SB model representing the high-rise buildings are identified via the smart combination of the subspace and inverse-mode methods. Since the shear and bending stiffnesses of the SB model can be identified in the inverse-mode method by using the lowest mode of horizontal displacements and floor rotation angles, the lowest mode of the objective building is identified first by using the subspace method. Identification of the lowest mode is performed by using the amplitude of transfer functions derived in the subspace method. Considering the resolution in measuring the floor rotation angles in lower stories, floor rotation angles in most stories are predicted from the floor rotation angle at the top floor. An empirical equation of floor rotation angles is proposed by investigating those for various building models. From the viewpoint of application of the present SI method to practical situations, a non-simultaneous measurement system is also proposed. In order to investigate the reliability and accuracy of the proposed SI method, a 10-story building frame subjected to micro-tremor is examined.

  13. Investigation on the feasibility and enhancement methods of wind power utilization in high-rise buildings of Hong Kong

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Lin; Ip, Ka Yan [Department of Building Services Engineering, The Hong Kong Polytechnic University (China)

    2009-02-15

    This paper reports the investigation results of wind power application in buildings. It is found that the concentration effect of buildings and the heights of buildings could enhance wind power utilization by increasing the wind speed by 1.5-2 x and wind power density by 3-8 x under the given simulation conditions. The wind aerodynamics and wind flows over the buildings are investigated based on local meteorological data and local high-rise building characteristics. This paper concludes that wind power utilization in high-rise buildings in Hong Kong is feasible theoretically, and some effective enhancement methods are proposed based on the simulation results, such as making full use of the heights of buildings and the concentration effect of buildings, and choosing optimal shape of building roof. However, to receive the highest potential wind energy resource and avoid turbulent areas, the tool of Computational Fluid Dynamics (CFD) has to be used to model the annual wind flows over buildings to help analyze, locate, and design wind turbines in and around buildings. (author)

  14. Study on prevention of spread of vertical fire along finishing materials for external wall of high-rise buildings

    Directory of Open Access Journals (Sweden)

    Yoo Yong Ho

    2013-11-01

    Full Text Available Although there are laws in the Korea Building Act relating to exterior finishing materials, fireproof structures and fire-stop of curtain wall structures, the standards relating to and test methods on securing detailed fire safety functions for exterior materials of all buildings including high-rise buildings have not been prepared. This is due to the fact that test methods and standards to quantitatively evaluate the vertical fire spread of the exterior material of buildings do not exist. In addition, while semi non-combustible materials or non-combustible materials are required to be used to prevent fire spread in buildings which exceed 30-stories, it is necessary to review the standards and regulations in cases where fire blocking systems, capable of preventing the vertical fire spread within the curtain wall, are installed to consider permitting the utilization of fire retardant material following an assessment of the construction characteristics of high-rise buildings. The functional evaluation standards and test methods on the vertical fire spread introduced in this study will be a more effective method for performing evaluations to prevent fire spread compared to the currently utilized method of performing small scale tests.

  15. SiC-based High Efficiency Bidirectional Battery Converter for Smart PV Residential Systems

    DEFF Research Database (Denmark)

    Pham, Cam; Biris, Valeriu-Ciprian; Teodorescu, Remus

    2013-01-01

    Smart PV inverters are essential components of future grids. Beside conventional functionalities they can communicate with the grid, supports the grid with reactive power and with active power from internal battery storage. To maximize internal consumption, a high efficiency bidirectional DC......-DC converter for the battery storage is necessary, as energy will be processed twice. Realisation of the battery converter with silicon carbide (SiC) semiconductors offers many advantages compared to Silicon (Si), included higher power density and higher efficiency. In this paper the design of a simple high...

  16. Determining the behaviour of high-rise structures with geodetic hybrid sensors

    Directory of Open Access Journals (Sweden)

    Hüseyin Pehlivan

    2015-11-01

    Full Text Available Observing the normal oscillations and the behaviours of high-engineering structures has become almost a necessity in terms of construction security and human health. For this purpose, an real-time kinematic GPS (NovAtel 400 and a tilt sensor (Leica Nivel20 were installed in a TV tower (220 m high located in Istanbul, Turkey. The observation serials were recorded over a period of 9 days. All data-sets in X and Y directions were examined in the time domain and were analyzed using FFT€. The dominant frequency values (significant frequencies were determined by comparing at the high- and low-frequency values. These dominant frequencies showed that the tower made 4- and 6-second short-period oscillations and 24- and 12-hour long-period oscillations. All the observation signals were re-created by the significant low-frequency values using the inverse Fourier transform. Thus, the motion model of the tower was determined over 9 days. In this study, the 24-hour and 12-hour periodic oscillations were defined that represent the behaviour of the tower in relation to the effect of the sun's radiation and the temperature changes.

  17. Residential Interior Design as Complex Composition: A Case Study of a High School Senior's Composing Process

    Science.gov (United States)

    Smagorinsky, Peter; Zoss, Michelle; Reed, Patty M.

    2006-01-01

    This research analyzed the composing processes of one high school student as she designed the interiors of homes for a course in interior design. Data included field notes, an interview with the teacher, artifacts from the class, and the focal student's concurrent and retrospective protocols in relation to her design of home interiors. The…

  18. Threatened and endangered subspecies with vulnerable ecological traits Also have high susceptibility to sea level rise and habitat fragmentation

    Science.gov (United States)

    Benscoter, Allison M.; Reece, Joshua S.; Noss, Reed F.; Brandt, Laura B.; Mazzotti, Frank J.; Romañach, Stephanie S.; Watling, James I.

    2013-01-01

    The presence of multiple interacting threats to biodiversity and the increasing rate of species extinction make it critical to prioritize management efforts on species and communities that maximize conservation success. We implemented a multi-step approach that coupled vulnerability assessments evaluating threats to Florida taxa such as climate change, sea-level rise, and habitat fragmentation with in-depth literature surveys of taxon-specific ecological traits. The vulnerability, adaptive capacity, and ecological traits of 12 threatened and endangered subspecies were compared to non-listed subspecies of the same parent species. Overall, the threatened and endangered subspecies showed high vulnerability and low adaptive capacity, in particular to sea level rise and habitat fragmentation. They also exhibited larger home ranges and greater dispersal limitation compared to non-endangered subspecies, which may inhibit their ability to track changing climate in fragmented landscapes. There was evidence for lower reproductive capacity in some of the threatened or endangered taxa, but not for most. Taxa located in the Florida Keys or in other low coastal areas were most vulnerable to sea level rise, and also showed low levels of adaptive capacity, indicating they may have a lower probability of conservation success. Our analysis of at-risk subspecies and closely related non-endangered subspecies demonstrates that ecological traits help to explain observed differences in vulnerability and adaptive capacity. This study points to the importance of assessing the relative contributions of multiple threats and evaluating conservation value at the species (or subspecies) level when resources are limited and several factors affect conservation success.

  19. Caving mining in coal seams lying beneath housing estates (high rise buildings)

    Energy Technology Data Exchange (ETDEWEB)

    Bogdan, A.; Gren, K.; Kowalski, A. (Kopalnia Murcki (Poland))

    1991-01-01

    Presents experience gained in extracting a coal seam by caving mining in the Murcki mine under a housing estate in a suburb of Katowice. Geological and mining conditions are described. Three 2.2 m high and 160 m long longwalls with a reach of 630-1,030 m were mined at a mean depth of 330 m in 1989 with a 40 m advance. Results of ground subsidence measurements at the mine surface are presented. The highest values measured were: subsidence 1.72 m, inclination 0.9%, extension 0.62% and compression 0.056. Discrepancy between calculated and measured values of deformations is discussed. Dependence of ground subsidence rate on longwall advance rate is considered. Final deflection of up to 12 storey high buildings out of plumb was 0.15% at the bottom part of the subsidence trough and 0.5-0.7% at the outskirts of the mining area. The measured ground deformation did not exceed the values for which the buildings were secured. 6 refs.

  20. Interdisciplinary design study of a high-rise integrated roof wind energy system

    Science.gov (United States)

    Dekker, R. W. A.; Ferraro, R. M.; Suma, A. B.; Moonen, S. P. G.

    2012-10-01

    Today's market in micro-wind turbines is in constant development introducing more efficient solutions for the future. Besides the private use of tower supported turbines, opportunities to integrate wind turbines in the built environment arise. The Integrated Roof Wind Energy System (IRWES) presented in this work is a modular roof structure integrated on top of existing or new buildings. IRWES is build up by an axial array of skewed shaped funnels used for both wind inlet and outlet. This inventive use of shape and geometry leads to a converging air capturing inlet to create high wind mass flow and velocity toward a Vertical Axis Wind Turbine (VAWT) in the center-top of the roof unit for the generation of a relatively high amount of energy. The scope of this research aims to make an optimized structural design of IRWES to be placed on top of the Vertigo building in Eindhoven; analysis of the structural performance; and impact to the existing structure by means of Finite Element Modeling (FEM). Results show that the obvious impact of wind pressure to the structural design is easily supported in different configurations of fairly simple lightweight structures. In particular, the weight addition to existing buildings remains minimal.

  1. Interdisciplinary design study of a high-rise integrated roof wind energy system

    Directory of Open Access Journals (Sweden)

    Moonen S.P.G.

    2012-10-01

    Full Text Available Today’s market in micro-wind turbines is in constant development introducing more efficient solutions for the future. Besides the private use of tower supported turbines, opportunities to integrate wind turbines in the built environment arise. The Integrated Roof Wind Energy System (IRWES presented in this work is a modular roof structure integrated on top of existing or new buildings. IRWES is build up by an axial array of skewed shaped funnels used for both wind inlet and outlet. This inventive use of shape and geometry leads to a converging air capturing inlet to create high wind mass flow and velocity toward a Vertical Axis Wind Turbine (VAWT in the center-top of the roof unit for the generation of a relatively high amount of energy. The scope of this research aims to make an optimized structural design of IRWES to be placed on top of the Vertigo building in Eindhoven; analysis of the structural performance; and impact to the existing structure by means of Finite Element Modeling (FEM. Results show that the obvious impact of wind pressure to the structural design is easily supported in different configurations of fairly simple lightweight structures. In particular, the weight addition to existing buildings remains minimal.

  2. Index-Based Assessment of Voltage Rise and Reverse Power Flow Phenomena in a Distribution Feeder Under High PV Penetration

    DEFF Research Database (Denmark)

    Hasheminamin, Maryam; Agelidis, Vassilios G.; Salehi, Vahid

    2015-01-01

    The proliferation of photovoltaic (PV) generation in low- and medium-voltage distribution networks is expected to continue. Qualified studies can quantify adverse impacts of high PV penetration on distribution networks and assist utilities in decision making. This paper proposes an index-based me......The proliferation of photovoltaic (PV) generation in low- and medium-voltage distribution networks is expected to continue. Qualified studies can quantify adverse impacts of high PV penetration on distribution networks and assist utilities in decision making. This paper proposes an index...... are used to confirm the effectiveness of the proposed indices. This paper derives the acceptable range of the proposed indices and safe margin, which have been compared with the basic active power curtailment method with no constraint, in order to avoid voltage rise. The IEEE 69-bus network is also...

  3. Mechanizing the Merc: The Chicago Mercantile Exchange and the Rise of High-Frequency Trading.

    Science.gov (United States)

    MacKenzie, Donald

    2015-07-01

    This article investigates one important strand in the evolution of today's high-frequency trading or HFT (the fast, automated trading of large numbers of financial securities). That strand is the history of the automation of trading on what has become the world's most prominent futures exchange, the Chicago Mercantile Exchange or Merc. The process of the automation of the Merc was episodic, often driven by responses to perceived external threats, and involved both "local" politics and transnational considerations. The article discusses the relationship between the Merc's automation and the embodied, deeply social trading practices of the Merc's open-outcry trading pits, and compares how the Merc was mechanized with the quite different-and in a sense more explicitly "social"-project of automation launched by the Merc's rival, the Chicago Board of Trade.

  4. Evaluation of health factors in high-rise buildings. 2. Bioclimatological consequences resulting from comparative measurements of the air ionisation in a high-rise building located in a heavily contaminated suburban area and at certain altitudes

    Energy Technology Data Exchange (ETDEWEB)

    M' ose, J.R.; Fischer, G.

    1981-01-01

    According to accepted scientific theories inhaled small ions deliver their charges in the pulmonary alveoli and this leads to local recharges. This process stimulates structures of the central nervous system and the activity of the endocrine is excited, resulting in an enhancement of the general well-being. In urban settings, it appears that large ions may be more prevalent and, therefore, are inhaled an increasing extent. They stick to the epithelia in the trachea and in the bronchi as well as the endothelia in the lung vesicles. The number of the ciliary movements in reduced. This results in a decreased ability of expectoration and a lower intake of oxygen by the alveoli. These facts could furnish an explanation for the increased vulnerability of city dwellers to infections diseases. The study also examines the effects of living in a high-rise building with respect to the different microclimates that may exist at different altitudes.

  5. THE QUIXOTIC QUEST FOR FAIRNESS: THE SEC’S ROLE IN THE RISE OF HIGH FREQUENCY TRADING

    Directory of Open Access Journals (Sweden)

    Janice Traflet

    2015-06-01

    Full Text Available This paper examines the complex factors facilitating the rise of high frequency trading (HFT from a historical perspective. Over the course of several decades, various stock market regulations and reforms, championed by the Securities and Exchange Commission (SEC, created room for HFT to develop and flourish. While advancements in technology initially may appear to be the primary cause of HFT, in fact, HFT could not exist (or at least, not to the extent it does today if certain rules and older ways of doing business on the exchanges were still in place, and if other regulations did not support its existence. This paper identifies multiple factors contributing to the eventual rise of HFT: decimalization, the decline of the specialist system, market fragmentation, rate deregulation, the repeal of the uptick rule, demutualization of the stock exchanges, and the institution of Regulation National Market System [NMS]. Moreover, it seeks to position these developments within the broader context of long-standing aims and themes embraced by the SEC.

  6. Does Accessibility to the Central Business District (CBD Have an Impact on High-Rise Condominium Price Gradient in Kuala Lumpur, Malaysia?

    Directory of Open Access Journals (Sweden)

    Dziauddin Mohd Faris

    2016-01-01

    Full Text Available This paper uses a spatial econometric method known as Geographically Weighted Regression (GWR to investigate the impact of accessibility to the CBD on the high-rise condominium price gradient in Kuala Lumpur, Malaysia. Using a GWR method, after having controlled other factors, this study clearly reveal the impact of accessibility to the CBD on high-rise condominium varying prices across the study area, having a much larger positive impact in some areas but less and counterintuitive impact in others. In general, the results from this study show accessibility to the CBD measured by the travel times does affect high-rise condominium prices (high-rise condominium prices decrease as travel times to the CBD increase in most part of the areas, hence proved Alonso, Muth and Mills were still right.

  7. Analysis of the Key and Difficult Points in the Engineering Construction Technology of the Steel Structures of a Super High-rise Building

    Science.gov (United States)

    Dou, Lijun; Li, Hengxu

    2017-07-01

    In recent years, with the rapid development of the economy of China, the traditional building structure has not been able to meet the current people’s demands and the super high-rise building has become a symbol of a city. In the current period, the research on the super high-rise building in the architectural industry of China is late and the technical blanks exist in some construction difficulties in the super high-rise steel structures. Based on the above, a brief analysis and discussion on the difficult construction technology in the steel structures of a super high-rise building and some measures are presented for reference of the relevant personnel in this paper.

  8. Static and dynamic analysis of high-rise building with consideration of two different values of subsoil stiffness coefficients

    Directory of Open Access Journals (Sweden)

    Ivankova Olga

    2017-01-01

    Full Text Available This paper deals with the analysis of 21-storeyed cast in-situ reinforced concrete high-rise building. Two different 3D models were created, because of two considered values of subsoil stiffness coefficient -fixed structure (alt. 1 and the structure supported by elastic soil (alt. 2. For both alternatives of foundation of structure, required analyses (static and dynamic were done and obtained results were compared in this paper. Short description of the structure, applied loads and other input parameters are also mentioned here. The main purpose of this analysis was to provide more information to planning engineers about the behaviour of structure exposed the wind load or seismic load when different soil conditions were considered.

  9. High-voltage isolation transformer for sub-nanosecond rise time pulses constructed with annular parallel-strip transmission lines.

    Science.gov (United States)

    Homma, Akira

    2011-07-01

    A novel annular parallel-strip transmission line was devised to construct high-voltage high-speed pulse isolation transformers. The transmission lines can easily realize stable high-voltage operation and good impedance matching between primary and secondary circuits. The time constant for the step response of the transformer was calculated by introducing a simple low-frequency equivalent circuit model. Results show that the relation between the time constant and low-cut-off frequency of the transformer conforms to the theory of the general first-order linear time-invariant system. Results also show that the test transformer composed of the new transmission lines can transmit about 600 ps rise time pulses across the dc potential difference of more than 150 kV with insertion loss of -2.5 dB. The measured effective time constant of 12 ns agreed exactly with the theoretically predicted value. For practical applications involving the delivery of synchronized trigger signals to a dc high-voltage electron gun station, the transformer described in this paper exhibited advantages over methods using fiber optic cables for the signal transfer system. This transformer has no jitter or breakdown problems that invariably occur in active circuit components.

  10. The Rise

    DEFF Research Database (Denmark)

    Tamke, Martin; Stasiuk, David; Ramsgaard Thomsen, Mette

    2013-01-01

    The research-based installation, The Rise, is led by the concept of a growing architecture able to sense and dynamically adapt to its environment as it grows into form while continuously reacting to its own material performance and behavioral constraints. This process is enabled through the careful...... a material system with simulation and the iterative generation of geometry through a process of calibration at different stages of design. The project leverages emerging computational strategies for growth in a model for an architectural practice that engages the complexity and interdependencies...

  11. Effective Pneumatic Scheme and Control Strategy of a Climbing Robot for Class Wall Cleaning on High-rise Buildings

    Directory of Open Access Journals (Sweden)

    Houxiang Zhang

    2006-06-01

    Full Text Available A new kind of pneumatic climbing robot is presented to meet the requirements of glass-wall cleaning for high-rise buildings, which is totally actuated by pneumatic cylinders and attached to the glass wall with vacuum suckers. Using the pneumatic actuators the climbing robot can be made lightweight and dexterous. At the same time the movement driven by pneumatic actuators has the characteristic of passive compliance. In order to solve the problems of high speed movement for the Y cylinder and precise position control of the X cylinder, the applied pneumatic schemes of X and Y cylinders are employed to drive the high-speed on-off solenoid valves and an ordinary valve to adjust the air-flow and pressure to the cylinders. Furthermore a method of segment and variable bang-bang controller is proposed to implement the accurate control of the position servo system for the X cylinder during the sideways movement. Testing results show that the novel approach can effectively improve the control quality. This cleaning robot can meet the requirements of realization.

  12. Effective Pneumatic Scheme and Control Strategy of a Climbing Robot for Class Wall Cleaning on High-rise Buildings

    Directory of Open Access Journals (Sweden)

    Guanghua Zong

    2008-11-01

    Full Text Available A new kind of pneumatic climbing robot is presented to meet the requirements of glass-wall cleaning for high-rise buildings, which is totally actuated by pneumatic cylinders and attached to the glass wall with vacuum suckers. Using the pneumatic actuators the climbing robot can be made lightweight and dexterous. At the same time the movement driven by pneumatic actuators has the characteristic of passive compliance. In order to solve the problems of high speed movement for the Y cylinder and precise position control of the X cylinder, the applied pneumatic schemes of X and Y cylinders are employed to drive the high-speed on-off solenoid valves and an ordinary valve to adjust the air-flow and pressure to the cylinders. Furthermore a method of segment and variable bang-bang controller is proposed to implement the accurate control of the position servo system for the X cylinder during the sideways movement. Testing results show that the novel approach can effectively improve the control quality. This cleaning robot can meet the requirements of realization.

  13. High quality and efficiency arc welding for steel frames of high-rise buildings; Chokoso biru tekkotsumuke kohinshitsu koseino yosetsu gijutsu no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Kurehashi, T.; Taniyama, N.; Nakanishi, Y.; Katayama, N. [Ishikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan)

    1997-03-01

    High current density narrow gap submerged arc welding method has been developed, high in quality and efficiency, for the preparation of steel frames for high-rise buildings. The conventional method is a heavy current, great heat input welding method using plural large-diameter wires. It demands huge facilities for power supply whose installation and management are quite complicated, and often gives rise to the anxiety that the produced weld may be defective, contain cracks, or reduced in toughness. In the method introduced here, the time-proved submerged arc welding method is applied to all the layers. In the newly developed high current density submerged arc welding technology, deep penetration and rich deposition protect toughness from deterioration, the quantity of input heat can be limited without lowering efficiency, and gaps can be made narrower for a reduction in the gap area. Penetration shapes are stable, welding heat input is appropriately specified for each welding pass, and fluctuation is reduced in the welding current and voltage. Thanks to heat input conditioned for each welding pass, welds are excellent in quality. The slag is easier to peel off, and incurs less defects, and the high melting speed results in excellent joint performance. 6 refs., 7 figs., 3 tabs.

  14. High frequency input impedance modeling of low-voltage residential installations - influence on lightning overvoltage simulations results.

    Science.gov (United States)

    Bassi, Welson

    2014-01-01

    The overvoltage level of a system is strongly dependent on the connected loads and with more precise models, better and more reliable simulation results are obtained. This paper presents the input impedance characteristics, measured over a wide range of frequencies, of various actual low-voltage residential installations. The measured frequency responses were fitted by effective RLC models and a general model was also developed. The range of frequencies considered in the study, nearly d.c. up to 5 MHz, allows the use of these models for lightning or switching studies. It is also presented overvoltage simulations, using different residential installations models presented in the paper, of a distribution network subjected to lightning surges on the medium voltage circuit.

  15. End-Use Load and Consumer Assessment Program: Characterizing residential thermal performance from high resolution end-use data

    Energy Technology Data Exchange (ETDEWEB)

    Miller, N.E.; Williamson, M.A.; Bailey, S.A.; Pratt, R.G.; Stokes, G.M.; Sandusky, W.F.; Pearson, E.W.; Roberts, J.S.

    1991-06-01

    This document is part of a two-volume set describing a series of thermal analyses of the residential buildings monitored under the End-Use Load and Consumer Assessment Program. Volume 1 describes in detail the thermal analysis methodology employed. Volume 2 presents the results of applying the methodology in a series of four distinct analyses: (1) an analysis of the first monitored heating season, 1985--1986; (2) an analysis of the second monitored heating season, (3) a comparison of first- and second-year analyses showing changes in residential consumption with changes in weather and evaluating the ability of the analytical technique to discriminate those changes; and (4) a continuation of the previous analyses evaluating the effects of foundation type and heating system type on the results.

  16. Sustainable Buildings for the High North. Existing buildings – technologies and challenges for residential and commercial use

    OpenAIRE

    Illikainen, Kimmo; Sirviö, Anu

    2015-01-01

    Depending on the intended use lifecycle of buildings may vary remarkably. Short term constructions such as summer cottages may last only a few decades whereas age of historical buildings may extend over hundreds of years. In Europe, three quarters of building stock is comprised of residential buildings. Approximately 40 % of the stock is built before 1960s, at the time when energy legislations were rather scarce. Consequently the age of buildings that have not undergone renovation i...

  17. Mitigation of the Impact of High Plug-in Electric Vehicle Penetration on Residential Distribution Grid Using Smart Charging Strategies

    Directory of Open Access Journals (Sweden)

    Chong Cao

    2016-12-01

    Full Text Available Vehicle electrification presents a great opportunity to reduce transportation greenhouse gas emissions. The greater use of plug-in electric vehicles (PEVs, however, puts stress on local distribution networks. This paper presents an optimal PEV charging control method integrated with utility demand response (DR signals to mitigate the impact of PEV charging to several aspects of a grid, including load surge, distribution accumulative voltage deviation, and transformer aging. To build a realistic PEV charging load model, the results of National Household Travel Survey (NHTS have been analyzed and a stochastic PEV charging model has been defined based on survey results. The residential distribution grid contains 120 houses and is modeled in GridLAB-D. Co-simulation is performed using Matlab and GridLAB-D to enable the optimal control algorithm in Matlab to control PEV charging loads in the residential grid modeled in GridLAB-D. Simulation results demonstrate the effectiveness of the proposed optimal charging control method in mitigating the negative impacts of PEV charging on the residential grid.

  18. Development and application of super heavy gauge high-strength structural steel for high-rise buildings

    Science.gov (United States)

    Gu, Linhao Gu; Lu, Shiping; Liu, Chunming; Liu, Jingang; Zhang, Suyuan; Chu, Rensheng; Ma, Changwen

    2017-09-01

    This paper presents development of 130mm S460G1-Z35 by using low carbon Nb-Ni-Mo-V-Ti micro-alloying design and two-stage rolling, quenching and tempering process. For the super heavy gauge high-strength structural steel, the yield strength is higher than 450MPa, the tensile strength is higher than 550MPa, the elongation is greater than 20%, the low temperature(-40) impact energy value is not less than 250J, the z-direction section shrinkage is more than 65%, and the welding performance is good. The plate are successfully applied to the engineering construction of the city of dreams in Macau.

  19. Humidity conditions in renovated high-rise buildings with three ventilation solutions. Luftfugtighed i renoverede hoejhuse med tre ventilationsloesninger

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, O.

    1989-01-01

    In connection with the renovation of two high-rise apartment buildings using different methods of ventilation The Danish Building Research Institute examined humidity conditions before and after renovation took place. Air velocities in the living area of one of the buildings were also examined. The methods of ventilation were those which occurs naturally through leaks and open windows only - with mechanical injection in living area and mechanical exhaust from kitchen and bathroom in addition to 20 cm2 outdoor air valve in living area facade and, thirdly, with sealed facades, windows and doors and a 30 cm2 valve in the facade of each room. Air velocity conditions were measured in three flats where mechanical injection and exhaust were established and where part of the indoor air was taken in unheated through valves in the facade. Significant variations were found in relation to the three ventilation methods. Significant variations in humidity conditions were found in relation to the three ventilation solutions. In the building with mechanical injection and exhaust the air humidity conditions were measured as satisfactory. Only in a few flats did the air humidity exceed the limit which might cause condensed moisture on normal double-glazed windows and above the value of about 45 per cent RF at 21 deg. C, often recommended as the upper limit in the coldest season to combat house dust mites. In the building with the original ventilation, with re-sealed facade and installation of a 30 cm2 valve in the facade of each room too high air humidities were measured in many of the flats. The mechanically injected air flow, and the air entering through the outdoor valves did not in general create too high air velocities in the living areas. (AB).

  20. A continuous-discrete approach for evaluation of natural frequencies and mode shapes of high-rise buildings

    Science.gov (United States)

    Malekinejad, Mohsen; Rahgozar, Reza; Malekinejad, Ali; Rahgozar, Peyman

    2016-09-01

    In this paper, a continuous-discrete approach based on the concept of lumped mass and equivalent continuous approach is proposed for free vibration analysis of combined system of framed tube, shear core and outrigger-belt truss in high-rise buildings. This system is treated as a continuous system (i.e., discrete beams and columns are replaced with equivalent continuous membranes) and a discrete system (or lumped mass system) at different stages of dynamic analysis. The structure is discretized at each floor of the building as a series of lumped masses placed at the center of shear core. Each mass has two transitional degrees of freedom (lateral and axial( and one rotational. The effect of shear core and outrigger-belt truss on framed tube system is modeled as a rotational spring placed at the location of outrigger-belt truss system along structure's height. By solving the resulting eigen problem, natural frequencies and mode-shapes are obtained. Numerical examples are presented to show acceptable accuracy of the procedure in estimating the fundamental frequencies and corresponding mode shapes of the combined system as compared to finite element analysis of the complete structure. The simplified proposed method is much faster and should be more suitable for rapid interactive design.

  1. Development of hybrid mass damper (TRIGON) for high-rise buildings; Chokoso biruyo hybrid mass damper (TRIGON) no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-10-31

    The hybrid mass damper TRIGON has been developed to reduce wind-and earthquake-induced vibrations of high-rise buildings. The present paper describes an experimental result executed to confirm the outline of the hybrid mass damper TRIGON and the control effect of the same. The present apparatus is a mass damper for reducing the response of a building by supporting a weight with a V shaped bottom with a roller and rocking the weight into a pendulum motion. A driving method is a hybrid one where there are both used a passive system in which an apparatus period defined by the angle of the weight bottom is tuned with a building period and an active system using an AC servo motor. It is further intended that the apparatus is made compact by neglecting the length of the pendulum by employing the V-shaped weight for supporting the roller. Building vibration tests are conducted to compare responses of the apparatus upon non-control and control. It is hereby confirmed that there can be added about 4 % of a damping factor of the first mode in the direction of the short side of the building as a control object for a satisfactory improvement of the dwelling property. 4 refs., 14 figs., 3 tabs.

  2. [On the evaluation of health factors in high-rise buildings 1. Behaviour of some environmental factors (author's transl)].

    Science.gov (United States)

    Möse, J R; Raber, J; Grill, D; Köck, M

    1981-01-01

    None of the test series carried out with completely different parameters (summation measurements of different type for SO2, fluorine, chlorides as well as germ counts for air) have indicated that the people living on the higher floors of tower blocks are exposed to a greater burden than those living on lower floors. On the contrary, the chloride analyses and also ther germ counts made on the balconies showed that such tower blocks are exposed to dust and dirt swirling up from the streets from the second up to the sixth floor (max. pollution on the third floor). In the stairwell, the highest germ count was made on the ground floor, as was to be expected. Needless to say, these results apply only to the conditions prevailing here. Somewhat different results may be obtained in other places, under different conditions regarding location and building structure. However, the results clearly show that the assumption that the upper storeys of high-rise buildings are exposed to a higher burden cannot be generally valid with respect to the parameters used. This is the least that our results indicate.

  3. An advanced vision-based system for real-time displacement measurement of high-rise buildings

    Science.gov (United States)

    Lee, Jong-Han; Ho, Hoai-Nam; Shinozuka, Masanobu; Lee, Jong-Jae

    2012-12-01

    This paper introduces an advanced vision-based system for dynamic real-time displacement measurement of high-rise buildings using a partitioning approach. The partitioning method is based on the successive estimation of relative displacements and rotational angles at several floors using a multiple vision-based displacement measurement system. In this study, two significant improvements were made to realize the partitioning method: (1) time synchronization, (2) real-time dynamic measurement. Displacement data and time synchronization information are wirelessly transferred via a network using the TCP/IP protocol. The time synchronization process is periodically conducted by the master system to guarantee the system time at the master and slave systems are synchronized. The slave system is capable of dynamic real-time measurement and it is possible to economically expand measurement points at slave levels using commercial devices. To verify the accuracy and feasibility of the synchronized multi-point vision-based system and partitioning approach, many laboratory tests were carried out on a three-story steel frame model. Furthermore, several tests were conducted on a five-story steel frame tower equipped with a hybrid mass damper to experimentally confirm the effectiveness of the proposed system.

  4. Copernicus Rising

    Science.gov (United States)

    Rose, Michael A.

    2007-08-01

    Copernicus Rising began as a historical biography when it was first conceived, but as the writing progressed it quickly became a rather absurd play that took historical research and twisted it through the lens of my own wit, philosophy and personal affection for the characters. When working with historical figures--characters who existed in a very tangible way in our own history--the playwriting process opens a dialogue between different points in time and space. The difficulty lies in finding a unique and clear voice amongst the discordant personalities involved in this time and space overlap, both in the writing and production processes, in order to get to the heart of what the play is really all about. This thesis follows the journey of the play from its historical roots through the creation of an absurd journey both insides and outside time, space and the human mind. The first part of the thesis explains the beginnings of the concept and outlines much of the research and development that went into the play. The next part outlines the process of production and integrating the world on paper with that of moving bodies on stage. In the final part, post-production discussions and audience feedback sessions shape the play into the draft included in this thesis.

  5. Residential Road Traffic Noise and High Depressive Symptoms after Five Years of Follow-up: Results from the Heinz Nixdorf Recall Study.

    Science.gov (United States)

    Orban, Ester; McDonald, Kelsey; Sutcliffe, Robynne; Hoffmann, Barbara; Fuks, Kateryna B; Dragano, Nico; Viehmann, Anja; Erbel, Raimund; Jöckel, Karl-Heinz; Pundt, Noreen; Moebus, Susanne

    2016-05-01

    Traffic noise affects a large number of people, particularly in urbanized areas. Noise causes stress and annoyance, but less is known about the relationship between noise and depression. We investigated the association of residential road traffic noise with depressive symptoms using 5-year follow-up data from a German population-based study. We analyzed data from 3,300 participants in the Heinz Nixdorf Recall study who were between 45 and 75 years old and were without depressive symptoms at baseline (2000-2003). Depressive symptoms were defined based on the Center for Epidemiologic Studies Depression scale (CES-D) 15-item questionnaire (total score ≥ 17) and antidepressant medication intake. Road traffic noise was modeled according to European Parliament/Council Directive 2002/49/EC. High noise exposure was defined as annual mean 24-hr noise levels > 55 A-weighted decibels [dB(A)]. Poisson regression with robust variance was used to estimate relative risks (RRs) a) adjusting for the potential confounders age, sex, socioeconomic status (SES), neighborhood-level SES, and traffic proximity; b) additionally adjusting for body mass index and smoking; and c) additionally adjusting for the potential confounders/intermediates comorbidities and insomnia. Overall, 35.7% of the participants were exposed to high residential road traffic noise levels. At follow-up (mean = 5.1 years after baseline), 302 participants were classified as having high depressive symptoms, corresponding to an adjusted RR of 1.29 (95% CI: 1.03, 1.62; Model 1) for exposure to > 55 versus ≤ 55 dB(A). Adjustment for potential confounders/intermediates did not substantially alter the results. Associations were stronger among those who reported insomnia at baseline (RR = 1.62; 95% CI: 1.10, 2.59 vs. RR = 1.21; 95% CI: 0.94, 1.57) and appeared to be limited to those with ≤ 13 years of education (RR = 1.43; 95% CI: 1.10, 1.85 vs. 0.92; 95% CI: 0.56, 1.53 for > 13 years). Our results suggest that

  6. Evaluation of health factors in high-rise buildings. 2. Bioclimatological consequences resulting from comparative measurements of the air ionisation in a high-rise building located in a heavily contaminated suburban area and at certain altitudes

    Energy Technology Data Exchange (ETDEWEB)

    Moese, J.R.; Fischer, G.

    1981-01-01

    According to accepted scientific theories inhaled small ions deliver their charges in the pulmonary alveoli and this leads to local recharges. This process stimulates structures of the central nervous system and the activity of the endocrine is excited, resulting in an enhancement of the general well-being. These possibilities of interpretation regarding a biological ionic effect are supported, with reservations by positive medical effects during and after a stay in a well-ventilated mountain climate or also in a sea-climate. Owing to their lower mobility the large ions are inhaled as small ions to an increasing extent. The chemical and physical noxa are delivered and deposited in the respiratory tract. They stick the epithelia in the trachea and in the bronchi as well as the endothelia in the lung vesicles. The number of the ciliary movements is reduced. Similar effects are known to be caused also by nicotine abuse. This results in a decreased ability of expectoration and a lower intake of oxygen by the alveoli. These facts could furnish an explanation for the increased vulnerability of city dwellers to infections diseases and to catarrh. The changed ionisation of air in urbanised areas definitely represents only one of the many risk factors. In addition to the attempt to characterize bioclimatically local weather conditions by means of the non-conventional parameter air ionisation our study has also been intended to establish biologically oriented criteria for the living in a high-rise building in a particularly unfavourable location. Under specific microclimatic conditions the uppermost storeys were at times bioclimatically favoured over the lowermost, especially when shallow air inversion is present. In such cases, small ions exclusively were registered in the upper storeys and large ions in the lower floors.

  7. A Bayesian kriging model for estimating residential exposure to air pollution of children living in a high-risk area in Italy

    Directory of Open Access Journals (Sweden)

    Ana M. Vicedo-Cabrera

    2013-11-01

    Full Text Available A core challenge in epidemiological analysis of the impact of exposure to air pollution on health is assessment of the individual exposure for subjects at risk. Geographical information systems (GIS-based pollution mapping, such as kriging, has become one of the main tools for evaluating individual exposure to ambient pollutants. We applied universal Bayesian kriging to estimate the residential exposure to gaseous air pollutants for children living in a high-risk area (Milazzo- Valle del Mela in Sicily, Italy. Ad hoc air quality monitoring campaigns were carried out: 12 weekly measurements for sulphur dioxide (SO2 and nitrogen dioxide (NO2 were obtained from 21 passive dosimeters located at each school yard of the study area from November 2007 to April 2008. Universal Bayesian kriging was performed to predict individual exposure levels at each residential address for all 6- to 12-years-old children attending primary school at various locations in the study area. Land use, altitude, distance to main roads and population density were included as covariates in the models. A large geographical heterogeneity in air quality was recorded suggesting complex exposure patterns. We obtained a predicted mean level of 25.78 (±10.61 μg/m3 of NO2 and 4.10 (±2.71 μg/m3 of SO2 at 1,682 children’s residential addresses, with a normalised root mean squared error of 28% and 25%, respectively. We conclude that universal Bayesian kriging approach is a useful tool for the assessment of realistic exposure estimates with regard to ambient pollutants at home addresses. Its prediction uncertainty is highly informative and can be used for both designing subsequent campaigns and for improved modelling of epidemiological associations.

  8. Identifying the unique ground motion signatures of supershear earthquakes - The one-two punch effect on high-rise buildings

    Science.gov (United States)

    Rosakis, A.; Mello, M.; Bhat, H.; Krishnan, S.; Kanamori, H.

    2011-12-01

    Directly studying earthquakes presents a host of insurmountable difficulties, the least of which is our inability to trigger earthquakes of various magnitudes at will and the lack of means of scrutinizing the behavior at depth while the quake propagates. We have developed techniques to produce miniature (or surrogate) laboratory earthquakes and follow their progress with high-speed imaging tools. Our laboratory quakes mimic actual ones, and have allowed us to demonstrate the existence of ruptures of super-shear or intersonic rupture speeds. The propagating fronts of such supershear ruptures feature a Mach-cone of shear shock waves similar to that of supersonic aircraft. For earthquake ruptures transitioning from sub-Rayleigh to supershear rupture speeds, this unusual shear Mach cone feature is also followed by a trailing Rayleigh disturbance which is all that remains of the old sub-Rayleigh rupture after transition is complete. Each propagating disturbance contributes to the unique ground motion signature in the near field. We refer to this as a one-two punch scenario. In particular, ground motion associated with passage of the shear Mach features a dominant fault-parallel velocity component while ground motion from the trailing Rayleigh field is characterized by a dominant fault-normal velocity component (characteristic of common, sub-shear earthquake ruptures). Appropriate scaling of the laboratory ground velocity measurements are used to shake 3-D numerical models of high-rise buildings (located in near fault locations) with hypothetical supershear and sub-Rayleigh earthquakes with unexpected implication to building safety and seismic hazard analysis.

  9. Buoyancy-Driven Ventilation Generated by the Double-Skin Façade of a High-Rise Building in Tropical Climate: Case Study Bandung, Indonesia

    Directory of Open Access Journals (Sweden)

    Aziiz Akhlish Diinal

    2017-01-01

    Full Text Available High-rise buildings in tropical region is identical to the use of mechanical Air Conditioning in massive scale. Nevertheless, there is an encouragement to high-rise buildings to reduce its energy consumptions, since they consume quite large amount of energy. This challenge can be overcome with various of strategies, one of them, by means of reducing the cooling load of mechanical Air Conditioning in high-rise building. Prospects come from the modern tall building design strategies, for example the use of double-skin façade to give addition of building skin which could provide indoor temperature protection from outside. Double-skin façade system has continued to increase in buildings in a tropical region such as in Indonesia. However, there is another potential of double skin façade, which is the possibility to increase the buoyancy effect in the air gap between the skin and building envelope. The possibility needs to be studied in order to give a proper way in designing double-skin façade of a high-rise building, especially on Bandung-Indonesia tropical climate. This paper explores the potential of double-skin façade in driving the air inside the façade to generate natural ventilation for a high-rise building in Bandung climate condition. Two parameters are used in exploring the buoyancy force, the width of double-skin façade and the temperature of the skin façade. In general, double-skin façade of a high-rise building in tropical climate can generate buoyancy driven ventilation for the building, it relates strongly to the distance between of the double-skin façade and the building envelope.

  10. Analysis of the systems of ventilation of residential houses of Ukraine and Estonia

    Science.gov (United States)

    Savchenko, Olena; Zhelykh, Vasyl; Voll, Hendrik

    2017-12-01

    The most common ventilation system in residential buildings in Ukraine is natural ventilation. In recent years, due to increased tightness of structures, an increase in the content of synthetic finishing materials in them, the quality of microclimate parameters deteriorated. One of the measures to improve the parameters of indoor air in residential buildings is the use of mechanical inflow and exhaust ventilation system. In this article the regulatory documents concerning the design of ventilation systems in Ukraine and Estonia and the requirements for air exchange in residential buildings are considered. It is established that the existing normative documents in Ukraine are analogous to European norms, which allow design the system of ventilation of residential buildings according to European standards. However, the basis for the design of ventilation systems in Ukraine is the national standards, in which mechanical ventilation, unfortunately, is provided only for the design of high-rise buildings. To maintain acceptable microclimate parameters in residential buildings, it is advisable for designers to apply the requirements for designing ventilation systems in accordance with European standards.

  11. The relationship between high residential density in student dormitories and anxiety, binge eating and Internet addiction: a study of Chinese college students.

    Science.gov (United States)

    Tao, Zhuoli; Wu, Gao; Wang, Zeyuan

    2016-01-01

    Although various studies have indicated that high residential density may affect health and psychological outcomes, to our knowledge, there have been no studies regarding the predictive nature of crowded living conditions on binge eating and the use of the Internet as coping strategies. A total of 1048 Chinese college students (540 males and 508 females) were randomly selected and asked to complete a battery of questionnaires that included the Zung's Self-Rating Anxiety Scale, the Internet Addiction Test, and Rosenbaum's Self-Control Scale. Binge eating behaviors and compensatory behaviors were also reported, and variables about residential density were measured. Among female participants, binge eating scores were significantly predicted by anxiety caused by high-density living conditions (P = 0.008), and similarly, the frequency of compensatory behaviors was significantly predicted by anxiety caused by high-density living conditions (P = 0.000) and self-control (P = 0.003). Furthermore, the Internet Addiction Test scores were significantly predicted by the anxiety caused by high -density living conditions (P = 0.000) and self-control (P = 0.000). Among male participants, not only were the binge eating scores significantly predicted by the anxiety caused by high-density living conditions (P = 0.000) and self-control (P = 0.000), but the frequency of compensatory behaviors was also significantly predicted by the anxiety caused by high-density living conditions (P = 0.000) and self-control (P = 0.01). Furthermore, Internet Addiction Test scores were significantly predicted by anxiety caused by high-density living conditions (P = 0.000) and self-control (P = 0.000). It was further found that for both genders, subjective factors such as self-control, and the anxiety caused by high-density living conditions had a stronger impact on Internet addiction than objective factors, such as the size of the student's dormitory room. Moreover, self

  12. Measuring the EMS patient access time interval and the impact of responding to high-rise buildings.

    Science.gov (United States)

    Morrison, Laurie J; Angelini, Mark P; Vermeulen, Marian J; Schwartz, Brian

    2005-01-01

    To measure the patient access time interval and characterize its contribution to the total emergency medical services (EMS) response time interval; to compare the patient access time intervals for patients located three or more floors above ground with those less than three floors above or below ground, and specifically in the apartment subgroup; and to identify barriers that significantly impede EMS access to patients in high-rise apartments. An observational study of all patients treated by an emergency medical technician paramedics (EMT-P) crew was conducted using a trained independent observer to collect time intervals and identify potential barriers to access. Of 118 observed calls, 25 (21%) originated from patients three or more floors above ground. The overall median and 90th percentile (95% confidence interval) patient access time intervals were 1.61 (1.27, 1.91) and 3.47 (3.08, 4.05) minutes, respectively. The median interval was 2.73 (2.22, 3.03) minutes among calls from patients located three or more stories above ground compared with 1.25 (1.07, 1.55) minutes among those at lower levels. The patient access time interval represented 23.5% of the total EMS response time interval among calls originating less than three floors above or below ground and 32.2% of those located three or more stories above ground. The most frequently encountered barriers to access included security code entry requirements, lack of directional signs, and inability to fit the stretcher into the elevator. The patient access time interval is significantly long and represents a substantial component of the total EMS response time interval, especially among ambulance calls originating three or more floors above ground. A number of barriers appear to contribute to delayed paramedic access.

  13. Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy

    Energy Technology Data Exchange (ETDEWEB)

    Fuller, Merrian C.

    2010-09-20

    Policy makers and program designers in the U.S. and abroad are deeply concerned with the question of how to scale up energy efficiency to a level that is commensurate both to the scale of the energy and climate challenges we face, and to the potential for energy savings that has been touted for decades. When policy makers ask what energy efficiency can do, the answers usually revolve around the technical and economic potential of energy efficiency - they rarely hone in on the element of energy demand that matters most for changing energy usage in existing homes: the consumer. A growing literature is concerned with the behavioral underpinnings of energy consumption. We examine a narrower, related subject: How can millions of Americans be persuaded to divert valued time and resources into upgrading their homes to eliminate energy waste, avoid high utility bills, and spur the economy? With hundreds of millions of public dollars flowing into incentives, workforce training, and other initiatives to support comprehensive home energy improvements, it makes sense to review the history of these programs and begin gleaning best practices for encouraging comprehensive home energy improvements. Looking across 30 years of energy efficiency programs that targeted the residential market, many of the same issues that confronted past program administrators are relevant today: How do we cost-effectively motivate customers to take action? Who can we partner with to increase program participation? How do we get residential efficiency programs to scale? While there is no proven formula - and only limited success to date with reliably motivating large numbers of Americans to invest in comprehensive home energy improvements, especially if they are being asked to pay for a majority of the improvement costs - there is a rich and varied history of experiences that new programs can draw upon. Our primary audiences are policy makers and program designers - especially those that are relatively

  14. Innovative Power-Augmentation-Guide-Vane Design of Wind-Solar Hybrid Renewable Energy Harvester for Urban High Rise Application

    Science.gov (United States)

    Tong, Chong Wen; Zainon, M. Z.; Chew, Poh Sin; Kui, Soo Chun; Keong, Wee Seng; Chen, Pan Kok

    2010-06-01

    To generate greater quantities of energy from wind, the most efficient solution would be by increasing the wind speed. Also, due to the decreasing number of economic wind energy sites, there are plans to place wind turbines closer to populated areas. To site wind turbines out from rural areas, the current problems of wind turbines need to be resolved, especially visual impact, poor starting behaviour in low wind speeds, noise and danger caused by blade failure. In this paper, a patented wind-solar hybrid renewable energy harvester is introduced. It is a compact system that integrates and optimizes several green elements and can be built on the top (or between upper levels) of high rise buildings or structures. This system can be used in remote and urban areas, particularly at locations where the wind speed is lower and more turbulent. It overcomes the inferior aspect on the low wind speed by guiding and increasing the speed of the high altitude free-stream wind through fixed or yaw-able power-augmentation-guide-vane (PAGV) before entering the wind turbine (straight-bladed vertical axis wind turbine, VAWT in this project) at center portion. PAGV is a new and innovative design where its appearance or outer design can be blended into the building architecture without negative visual impact. From the studies, it is shown that the wind speed increment in the PAGV can be produced according to the Bernoulli's principle. Computational fluid dynamics (CFD) simulation is used to optimize the geometry of the PAGV and the simulation results demonstrated the technical possibility of this innovative concept. The PAGV replaces the free air-stream from wind by multiple channels of speed-increased and directional-controlled air-stream. With the PAGV, this lift-type VAWT can be self-started and its size can be reduced for a given power output. The design is also safer since the VAWT is enclosed by the PAGV. By integrating the PAGV with the VAWT (the diameter and height of PAGV are 2

  15. Co-cultivation of murine BMDCs with 67NR mouse mammary carcinoma cells give rise to highly drug resistant cells

    Directory of Open Access Journals (Sweden)

    Zänker Kurt S

    2011-06-01

    Full Text Available Abstract Background Tumor tissue resembles chronically inflamed tissue. Since chronic inflammatory conditions are a strong stimulus for bone marrow-derived cells (BMDCs it can be assumed that recruitment of BMDCs into cancer tissue should be a common phenomenon. Several data have outlined that BMDC can influence tumor growth and metastasis, e.g., by inducing a paracrine acting feedback loop in tumor cells. Likewise, cell fusion and horizontal gene transfer are further mechanisms how BMDCs can trigger tumor progression. Results Hygromycin resistant murine 67NR-Hyg mammary carcinoma cells were co-cultivated with puromycin resistant murine BMDCs from Tg(GFPU5Nagy/J mice. Isolation of hygromycin/puromycin resistant mBMDC/67NR-Hyg cell clones was performed by a dual drug selection procedure. PCR analysis revealed an overlap of parental markers in mBMDC/67NR-Hyg cell clones, suggesting that dual resistant cells originated by cell fusion. By contrast, both STR and SNP data analysis indicated that only parental 67NR-Hyg alleles were found in mBMDC/67NR-Hyg cell clones favoring horizontal gene transfer as the mode of origin. RealTime-PCR-array analysis showed a marked up-regulation of Abcb1a and Abcb1b ABC multidrug transporters in mBMDC/67NR-Hyg clones, which was verified by Western Blot analysis. Moreover, the markedly increased Abcb1a/Abcb1b expression was correlated to an efficient Rhodamine 123 efflux, which was completely inhibited by verapamil, a well-known Abcb1a/Abcb1b inhibitor. Likewise, mBMDCs/67NR-Hyg clones revealed a marked resistance towards chemotherapeutic drugs including 17-DMAG, doxorubicin, etoposide and paclitaxel. In accordance to Rhodamine 123 efflux data, chemotherapeutic drug resistance of mBMDC/67NR-Hyg cells was impaired by verapamil mediated blockage of Abc1a/Abcb1b multidrug transporter function. Conclusion Co-cultivation of mBMDCs and mouse 67NR-Hyg mammary carcinoma cells gave rise to highly drug resistant cells. Even

  16. Nearly Zero Energy Standard for Non-Residential Buildings with high Energy Demands—An Empirical Case Study Using the State-Related Properties of BAVARIA

    Directory of Open Access Journals (Sweden)

    Michael Keltsch

    2017-03-01

    Full Text Available The Energy Performance of Buildings Directive (EPBD 2010 calls for the Nearly Zero Energy Building (nZEB Standard for new buildings from 2021 onwards: Buildings using “almost no energy” are powered by renewable sources or by the energy produced by the building itself. For residential buildings, this ambitious new standard has already been reached. But for other building types, this goal is still far away. The potential of these buildings to meet a nZEB Standard was investigated by analyzing ten case studies, representing non-residential buildings with different uses. The analysis shows that the primary characteristics common to critical building types are a dense building context with a very high degree of technical installation (such as hospital, research, and laboratory buildings. The large primary energy demand of these types of buildings cannot be compensated by building- and property-related energy generation, including off-site renewables. If the future nZEB Standard were to be defined with lower requirements because of this, the state-related properties of Bavaria suggest that the real potential energy savings available in at least 85% of all new buildings would be insufficiently exploited. Therefore, it would be more useful to individualize the legal energy verification process for new buildings, to distinguish critical building types such as laboratories and hospitals from the other building types.

  17. The Effect of Geometric Shape and Building Orientation on Minimising Solar Insolation on High-Rise Buildings in Hot Humid Climate

    Directory of Open Access Journals (Sweden)

    Chia Sok Ling

    2007-06-01

    Full Text Available High-rise buildings are experiencing overheating condition in hot humid climate. For a high-rise built form, vertical surfaces are the most critical to the impact of solar radiation. This study examines the effect of geometric shapes on the total solar insulation received by high-rise buildings. Two generic building shapes (square and circular have been studied with variations in width-to-length ratio (W/L ratio and building orientation using the computer simulation program ECOTECT V5.2. The results revealed that the circular shape with W/L ratio 1:1 is the most optimum shape in minimising total solar insulation. The square shape with W/L ratio 1:1 in a north-south orientation receives the lowest annual total solar insulation compared to other square shapes. This optimum shape (CC 1:1 receives the highest amount of solar insulation on the east-orientated wall, followed by the south-, west- and north-orientated walls respectively. This study guides designers on choosing optimum geometric shape and appropriate orientation for high-rise buildings.

  18. Operational modal analysis of a high-rise multi-function building with dampers by a Bayesian approach

    Science.gov (United States)

    Ni, Yanchun; Lu, Xilin; Lu, Wensheng

    2017-03-01

    The field non-destructive vibration test plays an important role in the area of structural health monitoring. It assists in monitoring the health status and reducing the risk caused by the poor performance of structures. As the most economic field test among the various vibration tests, the ambient vibration test is the most popular and is widely used to assess the physical condition of a structure under operational service. Based on the ambient vibration data, modal identification can help provide significant previous study for model updating and damage detection during the service life of a structure. It has been proved that modal identification works well in the investigation of the dynamic performance of different kinds of structures. In this paper, the objective structure is a high-rise multi-function office building. The whole building is composed of seven three-story structural units. Each unit comprises one complete floor and two L shaped floors to form large spaces along the vertical direction. There are 56 viscous dampers installed in the building to improve the energy dissipation capacity. Due to the special feature of the structure, field vibration tests and further modal identification were performed to investigate its dynamic performance. Twenty-nine setups were designed to cover all the degrees of freedom of interest. About two years later, another field test was carried out to measure the building for 48 h to investigate the performance variance and the distribution of the modal parameters. A Fast Bayesian FFT method was employed to perform the modal identification. This Bayesian method not only provides the most probable values of the modal parameters but also assesses the associated posterior uncertainty analytically, which is especially relevant in field vibration tests arising due to measurement noise, sensor alignment error, modelling error, etc. A shaking table test was also implemented including cases with and without dampers, which assists

  19. High Teas, High Collars and High Rise Buildings in a ‘High-Context’ Culture: The Semiotics of Japan’s Project of Modernity

    Directory of Open Access Journals (Sweden)

    Nicolas Adam Cambridge

    2017-01-01

    Full Text Available This article addresses a paradigm shift in Japanese society during the late nineteenth and early twentieth centuries – focusing on the encounters with Western culinary, sartorial and architectural practice experienced by a ‘high-context’ culture (Hall, 1976. The main discussion documents the differentiated reception of these changes – valorised by reformers for whom engaging with the outside world was key to their project of modernity, but treated with suspicion by members of the proletariat who feared for the purity of traditional Japanese values. The manner in which the resulting tensions were mediated through the print media and imagery of domestic visual culture is interrogated using a prism of semiotic analysis and the findings located within a contemporary context to suggest that Roland Barthes’ analytical approach to the country as an ‘empire of signs’ (Barthes, 1982 retains its original traction.

  20. Residential exposures to PM2.5 and CO in Cusco, a high-altitude city in the Peruvian Andes: a pilot study.

    Science.gov (United States)

    Pearce, John L; Aguilar-Villalobos, Manuel; Rathbun, Stephen L; Naeher, Luke P

    2009-01-01

    High-altitude populations using biofuels for household energy may be at health risk due to a combination of altitudinal stress and indoor exposures to biomass smoke. In this article, the authors measure indoor and outdoor breathing level concentrations of PM(2.5) and CO during periods of meal preparation in a convenience sample of homes above 3000 m in Cusco, Peru. From July 10 to 21, 2005, 237 measurements were taken during a pilot study at 41 residences. Results show the highest levels of PM(2.5) and CO occurred during the early morning in the kitchen when dung and wood were used. Additionally, findings suggest that residential biomass fuel combustion in Cusco results in elevated indoor PM(2.5) and CO exposure levels that are of potential human health concern, an issue that may be exacerbated by the physiological impact of living in a high-altitude environment.

  1. Rising Star: a Game-Changing Format in a Dying Genre. The Highs and Lows of a Format's Birth

    Directory of Open Access Journals (Sweden)

    Merav Schiffmann

    2016-08-01

    Full Text Available In the TV industry everyone is constantly searching for ‘the next big hit.’ For a brief moment in time, Rising Star perfectly fit this description. Within days of the Israeli launch of the first season, the format had already sold internationally to major territories. Rising Star boasted a first of its kind audience participation and a real-time live experience. This caught the attention of producers, executives and creators everywhere. This was a game-changing concept, set to shake the genre of reality singing competition shows to the core.The case study discussed in this paper examines the creation stages of a transmedia television format, the strains effecting its development, its rapid global roll-out and the international adaptations, primarily the failure on the US market and its negative ripple effect.

  2. Homogeneous swarm of high-Reynolds-number bubbles rising within a thin gap. Part 1: Bubble dynamics

    OpenAIRE

    Bouche, Emmanuella; Roig, Véronique; Risso, Frédéric; Billet, Anne-Marie

    2012-01-01

    The spatial distribution, the velocity statistics and the dispersion of the gas phase have been investigated experimentally in a homogeneous swarm of bubbles confined within a thin gap. In the considered flow regime, the bubbles rise on oscillatory paths while keeping a constant shape. They are followed by unstable wakes which are strongly attenuated due to wall friction. According to the direction that is considered, the physical mechanisms are totally different. In the vertical direction, t...

  3. Human Factors in Green Office Building Design: The Impact of Workplace Green Features on Health Perceptions in High-Rise High-Density Asian Cities

    Directory of Open Access Journals (Sweden)

    Fei Xue

    2016-10-01

    Full Text Available There is a growing concern about human factors in green building, which is imperative in high-rise high-density urban environments. This paper describes our attempts to explore the influence of workplace green features (such as green certification, ventilation mode, and building morphology on health perceptions (personal sensation, sensorial assumptions, healing performance based on a survey in Hong Kong and Singapore. The results validated the relationship between green features and health perceptions in the workplace environment. Remarkably, participants from the air-conditioned offices revealed significant higher concerns about health issues than those participants from the mixed-ventilated offices. The mixed-ventilation design performs as a bridge to connect the indoor environment and outdoor space, which enables people to have contact with nature. Additionally, the preferred building morphology of the workplace is the pattern of a building complex instead of a single building. The complex form integrates the configuration of courtyards, podium gardens, green terrace, public plaza, and other types of open spaces with the building clusters, which contributes to better health perceptions. This research contributes to the rationalization and optimization of passive climate-adaptive design strategies for green buildings in high-density tropical or subtropical cities.

  4. Development of a knowledge base used by an expert system to access the air quality in high-rise buildings

    Energy Technology Data Exchange (ETDEWEB)

    Miresco, E.; Windisch, H.; Gruia-Gray, J.

    1992-09-01

    The problem of poor air quality in buildings has developed relatively recently, due tp a large extent to the improved insulation and sealing of buildings for energy conservation. Research was conducted on an expert system as an aid to identify possible indoor air quality problems in highrise residential buildings, to identify the source of the problems, to aid in defining their nature and severity, and to produce a set of solutions to mitigate those problems. The knowledge base for the expert system was gathered primarily from literature on indoor air quality tests and field investigations. The resulting expert system is called EXPAIR and its features and operation are described. To assess the air quality in a highrise building, the user must supply information on the locations of the air quality problem, the physical findings that indicate the problem, and any symptoms reported by inhabitants of the building. By using EXPAIR's components of networks, variables, and dialogs, solutions are outlined at various levels of specificity. 2 figs., 4 tabs.

  5. Moisture Control Handbook: New, low-rise, residential construction

    Energy Technology Data Exchange (ETDEWEB)

    Lstiburek, J. [Building Science Corp., Chestnut Hill, MA (United States); Carmody, J. [Minnesota Univ., Minneapolis, MN (United States). Underground Space Center

    1991-10-01

    Moisture problems are prevalent all over North America, almost independent of climate. They are viewed as one of the single largest factors limiting the useful service life of a building. Elevated levels of moisture in buildings also can lead to serious health effects for occupants. Until recently, very little consensus on moisture control existed in the building community. The information available was typically incomplete, contradictory, usually limited to specific regions, and in many cases misleading. A need to develop a document which presented the issues relating to moisture from a building science or ``systems`` approach existed. This handbook attempts to fill that need and illustrates that energy-efficient, tight envelope design is clearly part of the solution to healthy buildings when interior relative humidity, temperature, and pressure are controlled simultaneously. The first three chapters of the handbook present the basic principles of moisture problems and solutions in buildings. Chapter 1 -- Mold, Mildew, and Condensation, examines surface moisture problems. Chapter 2 -- Moisture Movement, examines how building assemblies get wet from both the exterior and interior. Chapter 3 -- Wetting and Drying of Building Assemblies, introduces the concepts of acceptable performance, moisture balance, and the redistribution of moisture within building assemblies. Chapters 4 through 6 apply the concepts outlined in the previous chapters and present specific moisture control practices for three basic US climate zones. The advantages and disadvantages of several wall, foundation, and roof assemblies are discussed for each climate zone.

  6. Present state and future prospects in structural design and construction of high rise buildings; Chokoso kenchiku ni okeru sekkei seko gijutsu no genjo to sono shorai tenbo

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, S. [Mitsubishi Estate Co. Ltd., Tokyo (Japan)

    1994-12-05

    This paper reports the current state of design and construction of super high rise buildings quoting the case of Yokohama Landmark Tower as a central example, and describes the future prospects. Trends of load and stress in a super high rise building is such that the ratio of stress due to force in the axial direction occupying in the stress will increase with increasing height as can be understood if rectangular columns with different heights are compared. Axial force in a pillar acting against an earthquake may increase, but bending, shearing and beam stresses will remain unchanged. In buildings with heights of 250 to 300 meters, wind load stress can grow equivalent to or larger than an earthquake load stress. Designs standing on different concepts are required because of difference in the cycle and acting time of both stresses. At Yokohama Landmark Tower, many of the main frameworks were determined from the wind load, whereas 60-kg steels were used and the construction was carried out under elaborate controls. Since diversification of building shapes and ultra super high-rise construction are anticipated to be advanced in the future, expectations are focused on development of better high-strength steels, and automation and systematization in welding processes. 8 refs., 10 figs., 3 tabs.

  7. Mechanosensing in myosin filament solves a 60 years old conflict in skeletal muscle modeling between high power output and slow rise in tension

    CERN Document Server

    Marcucci, Lorenzo

    2016-01-01

    Almost 60 years ago Andrew Huxley with his seminal paper \\cite{Huxley1957} laid the foundation of modern muscle modeling, linking chemical events to mechanical performance. He described mechanics and energetics of muscle contraction through the cyclical attachment and detachment of myosin motors to the actin filament with ad hoc assumptions on the dependence of the rate constants on the strain of the myosin motors. That relatively simple hypothesis is still present in recent models, even though with several modifications to adapt the model to the different experimental constraints which became subsequently available. However, already in that paper, one controversial aspect of the model became clear. Relatively high attachment and detachment rates of myosin to the actin filament were needed to simulate the high power output at intermediate velocity of contraction. However, these rates were incompatible with the relatively slow rise in tension after activation, despite the rise should be generated by the same r...

  8. The energy-saving anaerobic baffled reactor membrane bioreactor (EABR-MBR) system for recycling wastewater from a high-rise building.

    Science.gov (United States)

    Ratanatamskul, Chavalit; Charoenphol, Chakraphan

    2015-01-01

    A novel energy-saving anaerobic baffled reactor-membrane bioreactor (EABR-MBR) system has been developed as a compact biological treatment system for reuse of water from a high-rise building. The anaerobic baffled reactor (ABR) compartment had five baffles and served as the anaerobic degradation zone, followed by the aerobic MBR compartment. The total operating hydraulic retention time (HRT) of the EABR-MBR system was 3 hours (2 hours for ABR compartment and very short HRT of 1 hour for aerobic MBR compartment). The wastewater came from the Charoen Wisawakam building. The results showed that treated effluent quality was quite good and highly promising for water reuse purposes. The average flux of the membrane was kept at 30 l/(m2h). The EABR-MBR system could remove chemical oxygen demand, total nitrogen and total phosphorus from building wastewater by more than 90%. Moreover, it was found that phosphorus concentration was rising in the ABR compartment due to the phosphorus release phenomenon, and then the concentration decreased rapidly in the aerobic MBR compartment due to the phosphorus uptake phenomenon. This implies that phosphorus-accumulating organisms inside the EABR-MBR system are responsible for biological phosphorus removal. The research suggests that the EABR-MBR system can be a promising system for water reuse and reclamation for high-rise building application in the near future.

  9. An Observer-Based Controller with a LMI-Based Filter against Wind-Induced Motion for High-Rise Buildings

    Directory of Open Access Journals (Sweden)

    Chao-Jun Chen

    2017-01-01

    Full Text Available Active mass damper (AMD control system is proposed for high-rise buildings to resist a strong wind. However, negative influence of noise in sensors impedes the application of AMD systems in practice. To reduce the adverse influence of noise on AMD systems, a Kalman filter and a linear matrix inequality- (LMI- based filter are designed. Firstly, a ten-year return period fluctuating wind load is simulated by mixed autoregressive-moving average (MARMA method, and its reliability is tested by wind speed power spectrum and correlation analysis. Secondly, a designed state observer with different filters uses wind-induced acceleration responses of a high-rise building as the feedback signal that includes noise to calculate control force in this paper. Finally, these methods are applied to a numerical example of a high-rise building and an experiment of a single span four-storey steel frame. Both numerical and experimental results are presented to verify that both Kalman filter and LMI-based filter can effectively suppress noise, but only the latter can guarantee the stability of AMD parameters.

  10. Study on application of flat plate structure to high-rise buildings; Flat plate kozo no koso tatemono eno tekiyo ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Takata, K.; Tsuda, K.; Eto, H. [Obayashi Corp., Tokyo (Japan)

    1999-01-10

    In this study, an improved flat plate structure was developed by an attempt to shift the critical section (the bending yield position) from the column surface towards the span center by increasing the amount of main reinforcement near the column joint. Performance testing of the improved flat plate structure to clarify its basic properties, it showed that its hysteresis characteristics were superior to those of the conventional type (the amount of main reinforcement is uniform in the direction of the axis of member). Based on the experimental results, the appraisal of hysteresis characteristics and the method of section computing were established as the design methods. These newly established design methods were applied to the existing 26-story high-rise building of RC construction, and a simulation was performed to analyze the effectiveness of the improved flat plate structure. The response results satisfied the design criteria for general high-rise buildings, thus confirming the feasibility of constructing high-rise buildings incorporating the flat plate structure. (author)

  11. Freely rising light solid spheres

    NARCIS (Netherlands)

    Veldhuis, Christian; Biesheuvel, A.; Lohse, Detlef

    2009-01-01

    This paper examines the behavior of spheres rising freely in a Newtonian fluid when the ratio between the density of the spheres and that of the surrounding fluid is about 0.02. High-speed imaging is used to reconstruct three-dimensional trajectories of the rising spheres. From the analysis of the

  12. Development of a model to simulate groundwater inundation induced by sea-level rise and high tides in Honolulu, Hawaii.

    Science.gov (United States)

    Habel, Shellie; Fletcher, Charles H; Rotzoll, Kolja; El-Kadi, Aly I

    2017-05-01

    Many of the world's largest cities face risk of sea-level rise (SLR) induced flooding owing to their limited elevations and proximities to the coastline. Within this century, global mean sea level is expected to reach magnitudes that will exceed the ground elevation of some built infrastructure. The concurrent rise of coastal groundwater will produce additional sources of inundation resulting from narrowing and loss of the vertical unsaturated subsurface space. This has implications for the dense network of buried and low-lying infrastructure that exists across urban coastal zones. Here, we describe a modeling approach that simulates narrowing of the unsaturated space and groundwater inundation (GWI) generated by SLR-induced lifting of coastal groundwater. The methodology combines terrain modeling, groundwater monitoring, estimation of tidal influence, and numerical groundwater-flow modeling to simulate future flood scenarios considering user-specified tide stages and magnitudes of SLR. We illustrate the value of the methodology by applying it to the heavily urbanized and low-lying Waikiki area of Honolulu, Hawaii. Results indicate that SLR of nearly 1 m generates GWI across 23% of the 13 km2 study area, threatening $5 billion of taxable real estate and 48 km of roadway. Analysis of current conditions reveals that 86% of 259 active cesspool sites in the study area are likely inundated. This suggests that cesspool effluent is currently entering coastal groundwater, which not only leads to degradation of coastal environments, but also presents a future threat to public health as GWI would introduce effluent at the ground surface. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Energy conservation in high-rise buildings: changes in air conditioning load induced by vertical temperature and humidity profile in Delhi

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, S. [Institute of Social Forestry and Eco-rehabilitation, ICFRE, Allahabad (India); Kumar, Sanjay [Indian Inst. of Technology, Centre for Atmospheric Sciences, New Delhi (India); Kumar, N. [MIT, Civil Engineering Dept., Bihar (India)

    1998-12-31

    Temperature and humidity profiles in the upper atmosphere are different from those observed by ground level meteorological stations and used to design HVAC systems for high-rise buildings. There exist correlations among solar energy, atmospheric turbidity and pollutants in urban areas, affecting the temperature and humidity profiles with variation in height. In the present study, a theoretical model is developed considering these parameters, and the HVAC load is calculated. The results are compared with the HVAC load calculated from data obtained from the meteorological station, and the comparison showed that the results differ significantly (20%) for a hypothetical 200 m high office building. (Author)

  14. Improvement of a Global High-Resolution Ammonia Emission Inventory for Combustion and Industrial Sources with New Data from the Residential and Transportation Sectors.

    Science.gov (United States)

    Meng, Wenjun; Zhong, Qirui; Yun, Xiao; Zhu, Xi; Huang, Tianbo; Shen, Huizhong; Chen, Yilin; Chen, Han; Zhou, Feng; Liu, Junfeng; Wang, Xinming; Zeng, Eddy Y; Tao, Shu

    2017-03-07

    There is increasing evidence indicating the critical role of ammonia (NH3) in the formation of secondary aerosols. Therefore, high quality NH3 emission inventory is important for modeling particulate matter in the atmosphere. Unfortunately, without directly measured emission factors (EFs) in developing countries, using data from developed countries could result in an underestimation of these emissions. A series of newly reported EFs for China provide an opportunity to update the NH3 emission inventory. In addition, a recently released fuel consumption data product has allowed for a multisource, high-resolution inventory to be assembled. In this study, an improved global NH3 emission inventory for combustion and industrial sources with high sectorial (70 sources), spatial (0.1° × 0.1°), and temporal (monthly) resolutions was compiled for the years 1960 to 2013. The estimated emissions from transportation (1.59 Tg) sectors in 2010 was 2.2 times higher than those of previous reports. The spatial variation of the emissions was associated with population, gross domestic production, and temperature. Unlike other major air pollutants, NH3 emissions continue to increase, even in developed countries, which is likely caused by an increased use of biomass fuel in the residential sector. The emissions density of NH3 in urban areas is an order of magnitude higher than in rural areas.

  15. Development of Residential SOFC Cogeneration System

    Science.gov (United States)

    Ono, Takashi; Miyachi, Itaru; Suzuki, Minoru; Higaki, Katsuki

    2011-06-01

    Since 2001 Kyocera has been developing 1kW class Solid Oxide Fuel Cell (SOFC) for power generation system. We have developed a cell, stack, module and system. Since 2004, Kyocera and Osaka Gas Co., Ltd. have been developed SOFC residential co-generation system. From 2007, we took part in the "Demonstrative Research on Solid Oxide Fuel Cells" Project conducted by New Energy Foundation (NEF). Total 57 units of 0.7kW class SOFC cogeneration systems had been installed at residential houses. In spite of residential small power demand, the actual electric efficiency was about 40%(netAC,LHV), and high CO2 reduction performance was achieved by these systems. Hereafter, new joint development, Osaka Gas, Toyota Motors, Kyocera and Aisin Seiki, aims early commercialization of residential SOFC CHP system.

  16. A feasibility study of temperature rise measurement in a tissue phantom as an alternative way for characterization of the therapeutic high intensity focused ultrasonic field.

    Science.gov (United States)

    Chen, Di; Fan, Tingbo; Zhang, Dong; Wu, Junru

    2009-12-01

    The feasibility that temperature field measurements in vitro as an alternative way to characterize the high intensity focused ultrasound (HIFU) field used in therapeutic applications has been explored in a phantom study. Thermocouples (copper-constantan, diameter 0.125 mm) are embedded in a phantom filled with tissue mimicking material that simulates the thermal and acoustic properties of soft-tissue. The temperature rises as a function of ultrasound exposure time near the focus of a HIFU transducer (1.1 MHz, active radius a=32 mm, geometric focal length=62 mm) of various acoustic powers up to 30 W are measured and compared with predicted values using a simple nonlinear Gaussian model. The experimental results can be explained well by the model if no acoustic cavitation takes place. When the acoustic power become higher (>5 W) and the local temperature elevation >15 degrees C and the local temperature is >40 degrees C at the focal point, cavitation vapor bubbles appear. The presence of the cavitation bubbles may increase the temperature rise rate initially. The bubble aggregates may form along the beam axis under sonication and then eventually makes the temperature elevation reach a saturated value. When acoustic cavitation occurs, the bubble-assisted enhancement of the initial temperature rise (exposure time t<2s) can still be predicted by the theory.

  17. Relations between residential and workplace segregation among newly arrived immigrant men and women

    NARCIS (Netherlands)

    Tammaru, T.; Strömgren, M.; Van Ham, M.; Danzer, A.M.

    2016-01-01

    Contemporary cities are becoming more and more diverse in population as a result of immigration. Research shows that while residential neighborhoods are becoming ethnically more diverse within cities, residential segregation from natives has overall remained persistently high. High levels of

  18. Residential photovoltaic system designs

    Energy Technology Data Exchange (ETDEWEB)

    Russell, M. C.

    1981-01-01

    A project to develop Residential Photovoltaic Systems has begun at Massachusetts Institute of Technology Lincoln Laboratory with the construction and testing of five Prototype Systems. All of these systems utilize a roof-mounted photovoltaic array and allow excess solar-generated electric energy to be fed back to the local utility grid, eliminating the need for on-site storage. Residential photovoltaic system design issues are discussed and specific features of the five Prototype Systems now under test are presented.

  19. Evidence of nonelectrochemical shift reaction on a CO-tolerant high-entropy state Pt-Ru anode catalyst for reliable and efficient residential fuel cell systems.

    Science.gov (United States)

    Takeguchi, Tatsuya; Yamanaka, Toshiro; Asakura, Kiyotaka; Muhamad, Ernee Noryana; Uosaki, Kohei; Ueda, Wataru

    2012-09-05

    A randomly mixed monodispersed nanosized Pt-Ru catalyst, an ultimate catalyst for CO oxidation reaction, was prepared by the rapid quenching method. The mechanism of CO oxidation reaction on the Pt-Ru anode catalyst was elucidated by investigating the relation between the rate of CO oxidation reaction and the current density. The rate of CO oxidation reaction increased with an increase in unoccupied sites kinetically formed by hydrogen oxidation reaction, and the rate was independent of anode potential. Results of extended X-ray absorption fine structure spectroscopy showed the combination of N(Pt-Ru)/(N(Pt-Ru) + N(Pt-Pt)) ≑ M(Ru)/(M(Pt) + M(Ru)) and N(Ru-Pt)/(N(Ru-Pt) + N(Ru-Ru)) ≑ M(Pt)/(M(Ru) + M(Pt)), where N(Pt-Ru)(N(Ru-Pt)), N(Pt-Pt)(N(Ru-Ru)), M(Pt), and M(Ru) are the coordination numbers from Pt(Ru) to Ru(Pt) and Pt (Ru) to Pt (Ru) and the molar ratios of Pt and Ru, respectively. This indicates that Pt and Ru were mixed with a completely random distribution. A high-entropy state of dispersion of Pt and Ru could be maintained by rapid quenching from a high temperature. It is concluded that a nonelectrochemical shift reaction on a randomly mixed Pt-Ru catalyst is important to enhance the efficiency of residential fuel cell systems under operation conditions.

  20. Serum feline-specific pancreatic lipase immunoreactivity concentrations and abdominal ultrasonographic findings in cats with trauma resulting from high-rise syndrome.

    Science.gov (United States)

    Zimmermann, Elke; Hittmair, Katharina M; Suchodolski, Jan S; Steiner, Jörg M; Tichy, Alexander; Dupré, Gilles

    2013-05-01

    To evaluate serum feline-specific pancreatic lipase immunoreactivity (fPLI) concentrations and abdominal ultrasonographic findings in cats with trauma resulting from high-rise syndrome. Prospective case series. Animals-34 client-owned cats. From cats evaluated because of high-rise syndrome between March and October 2009, a blood sample was obtained for measurement of serum fPLI concentration within 12 hours after the fall and at 24, 48, and 72 hours after the first blood collection. Pancreatitis was diagnosed in cats with an fPLI concentration > 5.4 μg/L. Each cat had abdominal ultrasonography performed twice 48 hours apart, and pancreatic trauma was assessed via detection of pancreatic enlargement, hypoechoic or heteroechoic pancreatic parenchyma, hyperechoic mesentery, and peritoneal effusion. Cats were assigned 1 point for each abnormality present, and a cumulative score ≥ 3 was considered suggestive of traumatic pancreatitis. Traumatic pancreatitis was diagnosed in 9 and 8 cats on the basis of serum fPLI concentration and ultrasonographic findings, respectively. For cats with pancreatitis, fPLI concentration was significantly higher at 12 and 24 hours after the fall than at 48 and 72 hours after the fall, and serum fPLI concentration decreased as time after the fall increased. Significant agreement existed between the use of serum fPLI concentration and abdominal ultrasonography for the diagnosis of traumatic pancreatitis. Cats with high-rise syndrome often had serum fPLI concentrations > 5.4 μg/L within 12 hours after the fall, and concurrent evaluation of those cats via abdominal ultrasonography twice, 48 hours apart, improved detection of traumatic pancreatitis.

  1. Strength and stability analysis of load-bearing structures of a high-rise building with account for actual positions of reinforced concrete structural members

    Directory of Open Access Journals (Sweden)

    Belostotskiy Aleksandr Mikhaylovich

    2015-04-01

    Full Text Available The given paper is devoted to strength and stability analysis of load-bearing structures of a high-rise (54-storey building with allowance for actual positions of reinforced concrete structural members (columns and walls. Finite element method (FEM is used for structural analysis. The authors present formulations of problems, governing equations, information about basic three-dimensional finite element models (so-called “design” (ideal model, the first “actual” model (taking into account the deviations of positions of columns from the project and the second “actual” model (taking into account the deviations of positions of walls from the project of the coupled system “high-rise building - foundation” within ANSYS Mechanical software and their verification, numerical approach to structural analysis and corresponding solvers. Finite element models include mainly 4-node structural shell elements (suitable for analyzing foundation slabs, floor slabs and load-bearing walls and three-dimensional 2-node beam elements (suitable for analyzing beams and columns, special spring-damper elements and multipoint constraint elements. Detailed finite element mesh on the bottom foundation slab is agreed with the location of piles. The advanced model of Prof. Yu.K. Zaretsky is used for approximation of soil behavior. Construction sequence and various types of nonlinearities are taken into account. The results of modal analysis, static and dynamic analysis with various load combinations (gravity load, facade load, dead (constant loads, temporary loads, wind load, snow load, crown load etc. are considered, the results of the regulatory assessment of the strength of structures (obtained with the use of corresponding software in accordance with design codes of the Russian Federation are under consideration as well. The corresponding displacements, stresses, natural vibration frequencies can be used for research and development of the correct monitoring

  2. The rising star of high-oleic Virginia peanuts: A summary of data supporting the release of 'VENUS'

    Science.gov (United States)

    'VENUS' is a large-seeded high-oleic Virginia-type peanut that has enhanced Sclerotinia blight and pod rot tolerance when compared to the cultivar Jupiter. 'VENUS' is the first high-oleic Virginia peanut developed for and proposed for release in the Southwestern US. 'VENUS' (experimental designati...

  3. Antimicrobial prescribing in residential homes.

    Science.gov (United States)

    McClean, Pamela; Tunney, Michael; Gilpin, Deirdre; Parsons, Carole; Hughes, Carmel

    2012-07-01

    Research in residential homes has been limited to date and the extent of systemic and topical antimicrobial prescribing is largely unknown. The aim of this study was to investigate antimicrobial prescribing in residential homes in Northern Ireland (NI). Point prevalence studies (PPSs) were completed in November 2010 (PPS1) and April 2011 (PPS2) in 30 residential homes. Data were obtained from care plans, medication administration records and staff in relation to antimicrobial prescribing and facility and resident characteristics, and analysed descriptively. The point prevalence of systemic antimicrobial prescribing was 9.4% in PPS1 and 9.2% in PPS2 (range 0.0%-33.3% during both PPSs). Trimethoprim was the most commonly prescribed systemic antimicrobial and the main indication was the prevention of urinary tract infections. Almost 25% of systemic antimicrobials were prescribed at inappropriate doses. The point prevalence of topical antimicrobial prescribing was 6.4% (range 0.0%-22.2%) in PPS1 and 5.9% (range 0.0%-21.1%) in PPS2. The most commonly prescribed topical antimicrobials were chloramphenicol eye preparations in PPS1 and fusidic acid skin preparations in PPS2; treatment with these topical antimicrobials was generally prolonged. More than 25% of all systemic and 55% of all topical antimicrobials were initiated following telephone consultations as opposed to face-to-face consultations. The prevalence of systemic antimicrobial prescribing in residential homes in NI is relatively high compared with care homes (particularly nursing homes) in other countries. Systemic and topical antimicrobial prescribing is not always appropriate in terms of the doses prescribed and the duration of use. It is apparent that current strategies employed in NI are insufficient to ensure prudent antimicrobial prescribing within this environment.

  4. Effects of a high-intensity functional exercise program on depressive symptoms among people with dementia in residential care: a randomized controlled trial.

    Science.gov (United States)

    Boström, Gustaf; Conradsson, Mia; Hörnsten, Carl; Rosendahl, Erik; Lindelöf, Nina; Holmberg, Henrik; Nordström, Peter; Gustafson, Yngve; Littbrand, Håkan

    2016-08-01

    The aim of this study is to evaluate the effect of a high-intensity functional exercise program on depressive symptoms among older care facility residents with dementia. Residents (n = 186) with a diagnosis of dementia, age ≥ 65 years, Mini-Mental State Examination score ≥ 10, and dependence in activities of daily living were included. Participants were randomized to a high-intensity functional exercise program or a non-exercise control activity conducted 45 min every other weekday for 4 months. The 15-item Geriatric Depression Scale (GDS) and the Montgomery-Åsberg Depression Rating Scale (MADRS) were administered by blinded assessors at baseline, 4, and 7 months. No difference between the exercise and control activity was found in GDS or MADRS score at 4 or 7 months. Among participants with GDS scores ≥ 5, reductions in GDS score were observed in the exercise and control groups at 4 months (-1.58, P = 0.001 and -1.54, P = 0.004) and 7 months (-1.25, P = 0.01 and -1.45, P = 0.007). Among participants with MADRS scores ≥ 7, a reduction in MADRS score was observed at 4 months in the control group (-2.80, P = 0.009) and at 7 months in the exercise and control groups (-3.17, P = 0.003 and -3.34, P = 0.002). A 4-month high-intensity functional exercise program has no superior effect on depressive symptoms relative to a control activity among older people with dementia living in residential care facilities. Exercise and non-exercise group activities may reduce high levels of depressive symptoms. Copyright © 2015 John Wiley & Sons, Ltd.

  5. Improving the safety of high-rise house-building based on the risk of introduction of protective actions

    Directory of Open Access Journals (Sweden)

    Ю.В. Верюжський

    2007-01-01

    Full Text Available  The analysis of various factors action that of probable threats of high-altitude buildings of mass construction influencing safety is lead. The estimation of a buildings safety from a position of their reliability and security from risks is given.

  6. Analysis of the Smoke Control Design in High-rise Building%高层建筑防排烟设计浅析

    Institute of Scientific and Technical Information of China (English)

    唐海明

    2014-01-01

    In the aspects of fire protection, the requirements of high-rise buildings are much higher than lower or multi-sto-rey building because of the large layer and difficult to rescue from the outside. Smoke control as an important measure of building fire protection plays a very important role in the fire escape and rescue. In this article, the author carries on a brief analysis and discussion of the problems in the high-rise buildi-ng smoke control design.%高层建筑由于层数多、火灾时外部救援难,在防火方面的要求远高于低层或多层建筑。防排烟作为建筑防火的一项重要措施,对火灾逃生及救援有着十分重要的作用。本文对高层建筑防排烟设计中碰到的一些问题进行简要的分析与探讨。

  7. Mechanosensing in myosin filament solves a 60 years old conflict in skeletal muscle modeling between high power output and slow rise in tension

    Directory of Open Access Journals (Sweden)

    Lorenzo Marcucci

    2016-09-01

    Full Text Available Almost 60 years ago Andrew Huxley with his seminal paper [Huxley1957] laid the foundation of modern muscle modeling, linking chemical events to mechanical performance. He described mechanics and energetics of muscle contraction through the cyclical attachment and detachment of myosin motors to the actin filament with ad hoc assumptions on the dependence of the rate constants on the strain of the myosin motors. That relatively simple hypothesis is still present in recent models, even though with several modifications to adapt the model to the different experimental constraints which became subsequently available. However, already in that paper, one controversial aspect of the model became clear. Relatively high attachment and detachment rates of myosin to the actin filament were needed to simulate the high power output at intermediate velocity of contraction. However, these rates were incompatible with the relatively slow rise in tension after activation, despite the rise should be generated by the same rate functions. This discrepancy has not been fully solved till today, despite several hypotheses have been forwarded to reconcile the two aspects.Here, using a conventional muscle model, we show that the recently revealed mechanosensing mechanism of recruitment of myosin motors [Linarietal2015] can solve this long standing problem without any further ad-hoc hypotheses.

  8. Assessment of safety culture among job positions in high-rise construction: a hybrid fuzzy multi criteria decision-making (FMCDM) approach.

    Science.gov (United States)

    Ardeshir, A; Mohajeri, M

    2018-01-16

    The construction industry is known as one of the most dangerous industries, which not only requires sound operation of executive laws and regulations, but also necessitates the safety culture of all workers at workshops. Therefore, the aim of this research is to identify the factors of safety culture and ranking occupations in jobsites based on those factors in order to proactively improve the safety culture of construction projects and subsequently promote safety conditions and worksites. In this study, safety culture criteria are weighted by a combination of Fuzzy Decision Trail and Evaluation Laboratory and Fuzzy ANP methods. Next, different job positions in high-rise projects are ranked using the Fuzzy Technique for Order of Preference by Similarity to Ideal Solution method. Findings demonstrated that the project manager, site superintendent and supervisor occupations had the highest and labourers had the lowest level of safety culture in the high-rise construction industry. Furthermore, factors such as safety supervision and training must be considered more seriously in order to create a positive safety culture among workers.

  9. Theoretical and experimental investigations on coherence of traffic noise transmission through an open window into a rectangular room in high-rise buildings.

    Science.gov (United States)

    Zhang, Jiping; Jiang, Weikang; Li, Ningrong

    2002-10-01

    A method for theoretically calculating the coherence between sound pressure inside a rectangular room in a high-rise building and that outside the open window of the room is proposed. The traffic noise transmitted into a room is generally dominated by low-frequency components, to which active noise control (ANC) technology may find an application. However, good coherence between reference and error signals is essential for an effective noise reduction and should be checked first. Based on traffic noise prediction methods, wave theory, and mode coupling theory, the results of this paper enabled one to determine the potentials and limitations of ANC used to reduce such a transmission. Experimental coherence results are shown for two similar, empty rectangular rooms located on the 17th and 30th floors of a 34 floor high-rise building. The calculated results with the proposed method are generally in good agreement with the experimental results and demonstrate the usefulness of the method for predicting the coherence.

  10. Collective resistance despite complicity: High identifiers rise above the legitimization of disadvantage by the in-group.

    Science.gov (United States)

    Jiménez-Moya, Gloria; Rodríguez-Bailón, Rosa; Spears, Russell; de Lemus, Soledad

    2017-03-01

    How do individuals deal with group disadvantage when their fellow in-group members conceive it as legitimate? Integrating research on the normative conflict model (Packer, 2008, Pers. Soc. Psychol. Rev., 12, 50) and collective action, we expect high identifiers to reject the in-group norm of legitimacy that justifies the inequality, and to assert that the group is actually able and willing to contest the disadvantage by collective means. In Study 1 and Study 2, we tested this hypothesis in different intergroup contexts. The results confirmed our predictions and also showed one boundary condition for high identifiers, namely that the content of the social identity supports resistance. In Study 3, we found support for our hypothesis using artificial groups and manipulating identification experimentally. These results show that even when a disadvantaged group appears to accept its situation, high identified in-group members will still contest this and, moreover, expect other in-group members to support them in this endeavour. © 2017 The British Psychological Society.

  11. Methodology for the Detection of Residential Vulnerable Areas – the Case of Barcelona

    Science.gov (United States)

    Cornado, Cossima; Garcia-Almirall, Pilar; Vima, Sara; Vila Busqued, Gemma; Uzqueda, Angel

    2017-10-01

    In a context of a shifting environmental, economic and social paradigm, European cities face a situation that is at the same time challenge and opportunity: the need for urban rehabilitation of the vulnerable degraded socio residential fabric. Public administrations in big cities and metropolitan areas are confronted with both the undercurrent need of actualization of the built stock and the rise of urban residential vulnerability. The city of Barcelona, as many others, is the result of multiple phenomena with high urban and social consequences. The socio spatial integration of immigrant population, the touristic rise and gentrification processes are current situations simultaneously taking place in the city. In parallel, a framework of economic crisis in which public investments in urban and social matters decrease, provides a temporal juncture that results into an increase of social polarization and socio economic inequality that becomes evident and expressed in the territory. This research focuses in the case of Barcelona, and presents a methodology based on a system of indicators elaborated through the exploitation of statistical data complemented with very specific data supplied by the Barcelona City Council. The accurate knowledge of socio demographic, socioeconomic and residential and urban characteristics is crucial in order to define the very complex urban dynamics that describe in the city neighbourhoods and areas. Residential vulnerability is defined as an assembly of objective conditions that relate to residential space and indicate situations of social discrimination and structural disadvantage of the population, related to a specific time and context. Thus, it is relevant to analyse the concentration of certain indicators of vulnerability in specific places or neighbourhoods, to contrast its effect on the socio-residential situation and its temporal evolution in order to identify tendencies. The present study contributes to the identification of data

  12. An automatic approach towards modal parameter estimation for high-rise buildings of multicomponent signals under ambient excitations via filter-free Random Decrement Technique

    Science.gov (United States)

    Nasser, Fatima; Li, Zhongyang; Martin, Nadine; Gueguen, Philippe

    2016-03-01

    This paper proposes an automatic modal analysis approach for signals of high-rise buildings recorded under real-world ambient excitations. The fact of working over such type of signals is faced with several challenges: the time-domain convolution between the system impulse response and the seismic noise, the existence of several components, the presence of closely-spaced frequency modes, with high additive noises, and low, exponential and damped amplitudes. The proposed approach handles these challenges simultaneously without the need for a user intervention. It is based on a filter-free Random Decrement Technique to estimate the free-decay response, followed by a spectral-based method for a rough modal estimate and finalized by a Maximum-Likelihood Estimation process to refine the modal estimates. Each of these processes is responsible to tackle one or more of the aforementioned challenges in the aim to provide an automatic and moreover a reliable modal analysis of the studied signals.

  13. Experimental Evaluation of Indoor Air Distribution in High-Performance Residential Buildings: Part I. General Descriptions and Qualification Tests

    Energy Technology Data Exchange (ETDEWEB)

    Jalalzadeh, A. A.; Hancock, E.; Powell, D.

    2007-12-01

    The main objective of this project is to experimentally characterize an air distribution system in heating mode during a period of recovery from setback. The specific air distribution system under evaluation incorporates a high sidewall supply-air register/diffuser and a near-floor wall return air grille directly below. With this arrangement, the highest temperature difference between the supply air and the room can occur during the recovery period and create a favorable condition for stratification. The experimental approach will provide realistic input data and results for verification of computational fluid dynamics modeling.

  14. Harmful Materials and Residential Demolition

    Science.gov (United States)

    Certain harmful or problematic materials present in residential buildings may need to be handled differently from general demolition debris. Here is a list of several specific types of materials that may be present in residential buildings.

  15. Growing bubbles rising in line

    Directory of Open Access Journals (Sweden)

    John F. Harper

    2001-01-01

    Full Text Available Over many years the author and others have given theories for bubbles rising in line in a liquid. Theory has usually suggested that the bubbles will tend towards a stable distance apart, but experiments have often showed them pairing off and sometimes coalescing. However, existing theory seems not to deal adequately with the case of bubbles growing as they rise, which they do if the liquid is boiling, or is a supersaturated solution of a gas, or simply because the pressure decreases with height. That omission is now addressed, for spherical bubbles rising at high Reynolds numbers. As the flow is then nearly irrotational, Lagrange's equations can be used with Rayleigh's dissipation function. The theory also works for bubbles shrinking as they rise because they dissolve.

  16. Rising to the Forensic Analytical Challenges Associated with the Global Increase in Seizures of Cathinone-derived "Legal Highs"

    Science.gov (United States)

    Sutcliffe, O.; Daeid, N. Nic; Kemp, H. F.; Meier-Augenstein, W.

    2012-04-01

    Substances touted as "legal highs" and known by names such as "ivory wave" or "NRG-1" mimic the effects of illegal drugs such as amphetamine, cocaine and ecstasy. Sold as "bath salts", plant food or incense these so-called "designer drugs" can be dangerous but despite this health danger many have not yet been made illegal and are difficult to detect with current drug tests. These "bath salts" can cause euphoria, paranoia, anxiety and hallucinations. They often contain mephedrone, a synthetic compound structurally related to methcathinone, which is found in Khat - a plant that, like mephedrone itself, is illegal to possess in many countries. "Bath salts" are usually labelled as being "not for human consumption" and the name "bath salts" is used by those who sell these substances as a way of circumventing legislation when supplying them. Mephedrone (a synthetic cathinone) was legal (or at least not illegal) in the UK until April 2010 when it was classified as a Class B, Schedule 1 substance (UK Misuse of Drugs Act 1971). The current challenges to law enforcement agencies are: (1) Identification and quantification of new and emerging illicit substances. (2) Tracing or linking product to precursor (i.e. source identification). Here, we present as a potential way of tracing the source of the raw materials, and consequently providing information as to who is making the "bath salts", which is based on identification of products and/or adulterants/excipients by GCMS in combination with isotopic profiling of both precursor and product to determine characteristic shifts or linkages in isotopic composition between starting material used, synthetic processes employed and resultant drug produced.

  17. Efficiency of the motion amplification device with viscous dampers and its application in high-rise buildings

    Science.gov (United States)

    Huang, Henry C.

    2009-12-01

    After nearly a decade of application and investigation, a motion amplification device with viscous dampers for energy dissipation has been recognized as an effective solution to mitigate wind or seismic excitation, especially for stiff structural systems. As a result of compensation of amplified motion, it has been proved that the efficiency of viscous damper largely depends on the motion amplification device configuration, particularly for device stiffness. In this paper, a “scissor-jack” type of motion amplification device, called a “toggle brace damper” system, is studied. It is demonstrated that the efficiency of such a device reflected by its amplification factor is not merely a function of its geometric configuration, but is highly dependent on the support elements’ stiffness as well, similar to the mechanism of a leverage arm. Accordingly, a mathematical model in terms of complex modulus of the viscous damper with consideration of the support brace’s stiffness is established. The results indicate that the efficiency of the motion amplification device with viscous dampers significantly depends on the stiffness of the support elements. Other parameters, such as toggle brace configuration and damping values of the viscous damper, are studied and compared. As an application example, numerical analyses are conducted to study the dynamic performance of a 39-story office tower installed with toggle brace dampers constructed on soft soil in a reclaimed area, under a combined effect of the vortex shedding of an adjacent existing 52-story building and earthquakes. The results show that viscous dampers with a motion amplification system using a properly designed toggle brace device proved to be an effective solution to alleviate the external excitations.

  18. Thermal surface analysis on high-rise building façades with neo-minimalist and modern style in Penang, Malaysia

    Science.gov (United States)

    Arab, Yasser; Hassan, Ahmad Sanusi; Qanaa, Bushra

    2017-10-01

    This research analyzed the façade thermal performance of high-rise buildings with modern and neo-minimalist architectural style. Four high-rise apartment buildings in Penang Island are selected as case studies for this research. The modern architectural style, which was popular during the 1970s to 1990s, nearly disregarded the cultural identity of the country and used the basic geometric shapes in the design. Conversely, the neo-minimalist style is the popular style from the 2010s up to the present. This style is a result of the "less is more" concept, which means using minimal applications to obtain an efficient design. The four selected case studies are as follows: Halaman Kristal 2 and Mutiara Idaman 1 with modern architectural style and Light Linear and Baystar apartments with neo-minimalist style. The research uses Fluke Ti20 thermal imager to capture thermal images of the west façade of the selected case studies on an hourly basis from 12:00 to 6:00 P.M. on March 15, 2017. Results confirm that the neo-minimalist façade elements, such as balconies and recessed walls, as well as other shading elements, are effective in improving the performance of façade shading. Notably, façade shading causes low surface temperature and provides cool indoor atmosphere during the day when the temperature is extremely high outside. Accordingly, this distinct feature partly explains the current popularity of the neo-minimalist architectural style.

  19. High-density, Low-rise - a challenge for Dwelling Landscapes in the Netherlands : Architectural Research by Design as a process towards incorporated typologies

    NARCIS (Netherlands)

    Kuitenbrouwer, P.A.M.; De Saeger, R.

    2015-01-01

    In the Netherlands, the topics of ‘cluttering’ of the landscape and ‘compact city’ at present guide the search for alternatives to suburban residential areas, which have taken too much space of open land. This paper discusses the very important issue of finding ways to comply with our growing need

  20. Family ties and residential locations

    NARCIS (Netherlands)

    Mulder, C.H.; Cooke, T.J.

    2009-01-01

    In this paper, and in the Special Issue it introduces, the focus is on the role of family ties in residential location choice and, conversely, the role of residential locations in maintaining family ties. Not only do events in the nuclear family trigger residential relocations, but nearby family

  1. 解析防排烟设计技术在高层建筑中的应用%Analysis of the Application of Smoke Control Technology in High-rise Building

    Institute of Scientific and Technical Information of China (English)

    孔海燕

    2014-01-01

    With the development of society and economy, high-rise buildings are increasing, and high-rise building sm-oke control design problems gradually aroused people's con-cern. This article through the analysis of the existing problems in the high-rise smoke control design, and carries on the deep discussion of smoke control system design method in high-rise building.%随着经济社会的发展,高层建筑日益增多,高层建筑防排烟设计问题逐渐引起人们的关注。文章通过分析高层防排烟设计中存在的问题,对高层建筑防排烟系统的设计方法进行了深入地探讨。

  2. The Role of Residential Segregation in Contemporary School Segregation

    Science.gov (United States)

    Frankenberg, Erica

    2013-01-01

    Inaction to address housing segregation in metropolitan areas has resulted in persistently high levels of residential segregation. As the Supreme Court has recently limited school districts' voluntary integration efforts, this article considers the role of residential segregation in maintaining racially isolated schools, namely what is known about…

  3. Continuing rise in oropharyngeal cancer in a high HPV prevalence area: A Danish population-based study from 2011 to 2014.

    Science.gov (United States)

    Carlander, Amanda-Louise Fenger; Grønhøj Larsen, Christian; Jensen, David Hebbelstrup; Garnæs, Emilie; Kiss, Katalin; Andersen, Luise; Olsen, Caroline Holkmann; Franzmann, Maria; Høgdall, Estrid; Kjær, Susanne K; Norrild, Bodil; Specht, Lena; Andersen, Elo; van Overeem Hansen, Thomas; Nielsen, Finn Cilius; von Buchwald, Christian

    2017-01-01

    Human papillomavirus (HPV) is a critical element in the rising incidence of oropharyngeal squamous cell carcinoma (OPSCC), although whether this trend will continue, and the types of HPV responsible, are currently unknown. We previously demonstrated an increased incidence of HPV-related OPSCC in the high HPV prevalence area of Eastern Denmark from 2000 to 2010. Therefore, we investigated if the incidence for OPSCC continued to rise, the association to HPV and putative HPV-types in Eastern Denmark from 2011 to 14. We then projected the expected incidence of OPSCC versus cervical cancer through to 2020. Patients with OPSCC (tonsillar squamous cell carcinoma [TSCC] and base of tongue squamous cell carcinoma [BSCC]) were identified via the Danish Head and Neck Cancer Group and the Danish Pathology Databank (n = 700). Tumours were re-reviewed and assessed using p16 immunohistochemistry, HPV DNA polymerase chain reaction (PCR), with genotyping by next generation sequencing. Sixty-two percent (432/700) of tumours were HPV-positive (HPV+). The total incidence rate (per 100.000) for OPSCC increased from 4.0 in 2011 to 4.5 in 2014, primarily due to a rise in HPV+ TSCCs and HPV+ BSCCs, although numbers of HPV-negative (HPV-) OPSCC also increased during the study period. The majority of HPV+ tumours were HPV16 DNA positive (86%), but we also identified HPV33 DNA (6%), HPV35 DNA (4%) and others (3%), including HPV18, 26, 31, 45, 56, 58, 59 and HPV67. An increasing incidence of OPSCC is driven primarily by HPV+ OPSCC. Sixty-two percent of tumours were HPV+, which is a high-prevalence, although the lower number of HPV- cases has yet to stabilise. HPV16 was the predominant genotype, although a significant proportion (14%) was of another genotype. Our projections suggest that the number of HPV+ OPSCC will exceed that of cervical cancer in 2016 in Eastern Denmark. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Discuss the High-rise Building Smoke Control Design%高层建筑防排烟设计探讨

    Institute of Scientific and Technical Information of China (English)

    宋丹辉

    2014-01-01

    With the speeding up of urbanization in China, high-rise buildings are increasing and the building internal functions tend to be more comprehensive and complicated with higher fire prevention requirements. Smoke control, as an important measure of building fire protection, has a very important role to the fire escape and rescue.%随着我国城市化进程的加快,高层建筑逐渐增多,建筑内部功能趋于综合化、复杂化,在防火方面的要求更高。防排烟作为建筑防火的一项重要措施,对火灾逃生及救援有着极为重要的作用。

  5. Comparison of the Efficiency of Tuned Mass and Tuned Liquid Dampers at High-Rise Structures under Near and Far Fault Earthquakes

    Directory of Open Access Journals (Sweden)

    Hamed Rahman Shokrgozar

    2017-02-01

    Full Text Available Tuned mass and tuned liquid dampers are most common passive control systems that used for decrease of seismic responses of buildings. In this study, the performance of high-rise buildings with TM and TL dampers are evaluated under seven near-fault and seven far-fault earthquakes. For this purpose, a twenty-four stories steel moment frame building has been considered and the time history dynamic analyses are performed for both of controlled and uncontrolled states. Moreover, this building has been also modelled with five various mass, stiffness and damping ratios.The results have been shown that decreasing the structural responses at tall buildings against near-fault earthquakes are more than far-fault earthquakes due to the effect of higher modes. Furthermore, the tuned mass damper has better performance at decreasing of the responses in comparison of tuned liquid dampers.

  6. Continuing rise in oropharyngeal cancer in a high HPV prevalence area: A Danish population-based study from 2011 to 2014

    DEFF Research Database (Denmark)

    Carlander, Amanda-Louise Fenger; Larsen, Christian Grønhøj; Jensen, David Hebbelstrup

    2017-01-01

    and HPV+ BSCCs, although numbers of HPV-negative (HPV–) OPSCC also increased during the study period. The majority of HPV+ tumours were HPV16 DNA positive (86%), but we also identified HPV33 DNA (6%), HPV35 DNA (4%) and others (3%), including HPV18, 26, 31, 45, 56, 58, 59 and HPV67. Conclusion...... An increasing incidence of OPSCC is driven primarily by HPV+ OPSCC. Sixty-two percent of tumours were HPV+, which is a high-prevalence, although the lower number of HPV– cases has yet to stabilise. HPV16 was the predominant genotype, although a significant proportion (14%) was of another genotype. Our......Background Human papillomavirus (HPV) is a critical element in the rising incidence of oropharyngeal squamous cell carcinoma (OPSCC), although whether this trend will continue, and the types of HPV responsible, are currently unknown. We previously demonstrated an increased incidence of HPV...

  7. Going upward in wood. Pilot project. Wooden multi-storey buildings up to the high-rise height; Hoch hinaus in Holz. Pilotprojekt. Hoelzerne Geschossbauten bis zur Hochhausgrenze

    Energy Technology Data Exchange (ETDEWEB)

    Schankula, Arthur [Architekturbuero Arthur Schankula, Muenchen (Germany)

    2011-07-01

    At the site of a former U.S. barrack in the Bavarian town Bad Aibling, the Office Schankula Architekten (Munich, Federal Republic of Germany) and the timber construction company Huber and Sohn GmbH and Co. KG (Eiselfing, Federal Republic of Germany) realized a concept for the construction of storey buildings made of wood up to the high-rise height together with the engineering office Bauart (Berlin, Federal Republic of Germany). The project is supported by the German Federal Environmental Foundation (Osnabrueck, Federal Republic of Germany) and is embedded in the project funded by the Federal Ministry of Economics and Technology (Berlin, Federal Republic of Germany) 'Zero energy district Bad Aibling'. Here, the company B and O (Muenchen, Federal Republic of Germany) as a service provider for the housing industry developed one of the most important locations of the experimental housing.

  8. Residential Solar Systems.

    Science.gov (United States)

    Fulkerson, Dan

    This publication contains student and teacher instructional materials for a course in residential solar systems. The text is designed either as a basic solar course or as a supplement to extend student skills in areas such as architectural drafting, air conditioning and refrigeration, and plumbing. The materials are presented in four units…

  9. Towards safer residential areas.

    NARCIS (Netherlands)

    Kraay, J.H. Mathijssen, M.P.M. & Wegman, F.C.M.

    1985-01-01

    In recent years there has been an increasing interest, both by social institutions and by scientists, in the promotion of traffic safety and in the improvement of the living environment in residential areas. For this purpose use can be made of an extended range of measures, influencing the

  10. Residential Mechanical Precooling

    Energy Technology Data Exchange (ETDEWEB)

    German, a. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Hoeschele, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2014-12-01

    This research conducted by the Alliance for Residential Building Innovation team evaluated mechanical air conditioner pre-cooling strategies in homes throughout the United States. EnergyPlus modeling evaluated two homes with different performance characteristics in seven climates. Results are applicable to new construction homes and most existing homes built in the last 10 years, as well as fairly efficient retrofitted homes.

  11. Potential of shading devices and glazing configurations on cooling energy savings for high-rise office buildings in hot-humid climates: The case of Malaysia

    Directory of Open Access Journals (Sweden)

    Allen Khin Kiet Lau

    2016-12-01

    Full Text Available Rapid growing of energy use has raised critical concerns over energy supply difficulties and negative environmental impacts globally and among ASEAN countries. Malaysia is experiencing a high average annual energy demand growth rate of approximately 2.3% which large portion of that energy is used by office buildings. Under the hot-humid climatic conditions in Malaysia, high-rise office buildings with large or fully glazed façades are facing a major problem of overheating due to high solar radiation through the glazed façades. This has caused high cooling energy requirements. The aim of this study is to investigate the potential of three types of shading devices on cooling energy savings when applied at different façade orientations. The aim also extends to investigations on different cooling energy savings when shading devices are applied on façade glazing with different configurations and thermal performances. This was done through a case study of a high-rise office building in Kuala Lumpur, Malaysia using IES (VE building thermal simulation software. Twenty simulation building models were applied with different shading devices at different façade orientations and with high and low performance façade glazing. The simulation results indicate that high-rise office buildings in Malaysia use approximately 45.9% of total building energy for cooling purposes. The results also suggest that use of various shading devices on low-e double glazed façades will result between 1.0% and 3.4% annual cooling energy savings, depending on the types of shading devices and façade orientations. The estimated annual cooling energy savings increase to between 5.0% and 9.9% when the shading devices are applied to all orientations of low-e double glazed façades. The estimated annual cooling energy savings further increase to between 5.6% and 10.4% when the façade glazing is replaced by single clear glazing. This study recommends prioritizing shading devices on

  12. Solar Photovoltaic Financing: Residential Sector Deployment

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, J.; Cory, K.

    2009-03-01

    This report presents the information that homeowners and policy makers need to facilitate PV financing at the residential level. The full range of cash payments, bill savings, and tax incentives is covered, as well as potentially available solar attribute payments. Traditional financing is also compared to innovative solutions, many of which are borrowed from the commercial sector. Together, these mechanisms are critical for making the economic case for a residential PV installation, given its high upfront costs. Unfortunately, these programs are presently limited to select locations around the country. By calling attention to these innovative initiatives, this report aims to help policy makers consider greater adoption of these models to benefit homeowners interested installing a residential PV system.

  13. 77 FR 29322 - Updating State Residential Building Energy Efficiency Codes

    Science.gov (United States)

    2012-05-17

    ...The Department of Energy (DOE or Department) has determined that the 2012 edition of the International Code Council (ICC) International Energy Conservation Code (IECC) (2012 IECC or 2012 edition) would achieve greater energy efficiency in low-rise residential buildings than the 2009 IECC. Upon publication of this affirmative final determination, States are required to file certification statements to DOE that they have reviewed the provisions of their residential building code regarding energy efficiency and made a determination as to whether to update their code to meet or exceed the 2012 IECC. Additionally, this Notice provides guidance to States on how the codes have changed from previous versions, and the certification process.

  14. Influence of Macroeconomic Factors on Residential Property ...

    African Journals Online (AJOL)

    Sultan

    An attempt was made in this study to bridge the existing gap in the knowledge of the influence exerted by macroeconomic factors on residential .... inflation, high level of employment, low level of unemployment and balanced economic ... employment rate on property returns 1s consistent with that of Apergi (2003). Sari et al.

  15. Possible impacts of sea-level rise on the Diep river/Rietvlei system, Cape-Town

    CSIR Research Space (South Africa)

    Hughes, P

    1993-10-01

    Full Text Available Many of the Cape Province's estuaries and tidal inlets have sandy connections to the sea and are often intensively developed for industrial or residential purposes. The possible impacts of sea-level rise are of considerable interest...

  16. Detailed residential electric determination

    Energy Technology Data Exchange (ETDEWEB)

    1984-06-01

    Data on residential loads has been collected from four residences in real time. The data, measured at 5-second intervals for 53 days of continuous operation, were statistically characterized. An algorithm was developed and incorporated into the modeling code SOLCEL. Performance simulations with SOLCEL using these data as well as previous data collected over longer time intervals indicate that no significant errors in system value are introduced through the use of long-term average data.

  17. Guidelines for residential commissioning

    Energy Technology Data Exchange (ETDEWEB)

    Wray, Craig P.; Walker, Iain S.; Sherman, Max H.

    2003-01-31

    Currently, houses do not perform optimally or even as many codes and forecasts predict, largely because they are field assembled and there is no consistent process to identify problems or to correct them. Residential commissioning is a solution to this problem. This guide is the culmination of a 30-month project that began in September 1999. The ultimate objective of the project is to increase the number of houses that undergo commissioning, which will improve the quality, comfort, and safety of homes for California citizens. The project goal is to lay the groundwork for a residential commissioning industry in California focused on end-use energy and non-energy issues. As such, we intend this guide to be a beginning and not an end. Our intent is that the guide will lead to the programmatic integration of commissioning with other building industry processes, which in turn will provide more value to a single site visit for people such as home energy auditors and raters, home inspectors, and building performance contractors. Project work to support the development of this guide includes: a literature review and annotated bibliography, which facilitates access to 469 documents related to residential commissioning published over the past 20 years (Wray et al. 2000), an analysis of the potential benefits one can realistically expect from commissioning new and existing California houses (Matson et al. 2002), and an assessment of 107 diagnostic tools for evaluating residential commissioning metrics (Wray et al. 2002). In this guide, we describe the issues that non-experts should consider in developing a commissioning program to achieve the benefits we have identified. We do this by providing specific recommendations about: how to structure the commissioning process, which diagnostics to use, and how to use them to commission new and existing houses. Using examples, we also demonstrate the potential benefits of applying the recommended whole-house commissioning approach to

  18. The integration of photovoltaics within high rise buildings in the dense urban environments of SE Asia, considerations of legislation to promote it and to maintain solar energy access

    Energy Technology Data Exchange (ETDEWEB)

    Close, J. [University of Hong Kong (Hong Kong). Dept. of Architecture

    1996-05-01

    The consensus of the `92 Rio summit was that all development should aim for sustainable development. The major growth region for the next decade is SE Asia, particularly the cities of South China for which Hong Kong is a role model. Current buildings are heavily dependent on air-conditioning while planning legislation plus cost factors have inhibited the use of external shading devices and building codes have failed to introduce comprehensive integrated standards for energy conservation. Photovoltaics are a renewable energy resource without harmful effects on the environment. The technology is maturing and high efficiency low-cost cells starting in commercial production. Opportunities exist for photovoltaic arrays as shading and cladding panels in high-rise construction. Hong Kong`s solar radiation has been analysed, and the power potential of photovoltaic cladding and shading of a commercial building simulated. A 12 month study of photovoltaics has been set up to monitor real values in the urban context. Changes in present energy generation strategies are discussed, through NFFO and DSM, to assist the take-up of photovoltaics in buildings as well as the need for legislation to maintain solar access. (author)

  19. Evaluating the physical demands when using sled-type stair descent devices to evacuate mobility-limited occupants from high-rise buildings.

    Science.gov (United States)

    Lavender, Steven A; Mehta, Jay P; Hedman, Glenn E; Park, Sanghyun; Reichelt, Paul A; Conrad, Karen M

    2015-09-01

    The physical demands on evacuators were investigated when using different types of sled-type stair descent devices designed for the emergency evacuation of high rise buildings. Twelve firefighters used six sled-type stair descent devices during simulated evacuations. The devices were evaluated under two staircase width conditions (1.12, and 1.32 m). Dependent measures included electromyographic (EMG) data, heart rates, Borg Scale ratings, and descent velocities. All stair descent speeds were below those reported during pedestrian egress trials. With the exception of the inflatable device, the devices operated by two evacuators had higher descent speeds than those operated by a single evacuator. High friction materials under the sleds facilitated control and reduced the muscle demands on stairs but increased physical demands on the landings. Usability assessments found devices with shorter overall lengths had fewer wall contacts on the landing, and handles integrated in the straps were preferred by the evacuators. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  20. Design of AN Intelligent Individual Evacuation Model for High Rise Building Fires Based on Neural Network Within the Scope of 3d GIS

    Science.gov (United States)

    Atila, U.; Karas, I. R.; Turan, M. K.; Rahman, A. A.

    2013-09-01

    One of the most dangerous disaster threatening the high rise and complex buildings of today's world including thousands of occupants inside is fire with no doubt. When we consider high population and the complexity of such buildings it is clear to see that performing a rapid and safe evacuation seems hard and human being does not have good memories in case of such disasters like world trade center 9/11. Therefore, it is very important to design knowledge based realtime interactive evacuation methods instead of classical strategies which lack of flexibility. This paper presents a 3D-GIS implementation which simulates the behaviour of an intelligent indoor pedestrian navigation model proposed for a self -evacuation of a person in case of fire. The model is based on Multilayer Perceptron (MLP) which is one of the most preferred artificial neural network architecture in classification and prediction problems. A sample fire scenario following through predefined instructions has been performed on 3D model of the Corporation Complex in Putrajaya (Malaysia) and the intelligent evacuation process has been realized within a proposed 3D-GIS based simulation.

  1. The American Indian Summer Institute in Earth System Science (AISESS) at UC Irvine: A Two-Week Residential Summer Program for High School Students

    Science.gov (United States)

    Johnson, K. R.; Polequaptewa, N.; Leon, Y.

    2012-12-01

    Native Americans remain severely underrepresented in the geosciences, despite a clear need for qualified geoscience professionals within Tribal communities to address critical issues such as natural resource and land management, water and air pollution, and climate change. In addition to the need for geoscience professionals within Tribal communities, increased participation of Native Americans in the geosciences would enhance the overall diversity of perspectives represented within the Earth science community and lead to improved Earth science literacy within Native communities. To address this need, the Department of Earth System Science and the American Indian Resource Program at the University California have organized a two-week residential American Indian Summer Institute in Earth System Science (AISESS) for high-school students (grades 9-12) from throughout the nation. The format of the AISESS program is based on the highly-successful framework of a previous NSF Funded American Indian Summer Institute in Computer Science (AISICS) at UC Irvine and involves key senior personnel from the AISICS program. The AISESS program, however, incorporates a week of camping on the La Jolla Band of Luiseño Indians reservation in Northern San Diego County, California. Following the week of camping and field projects, the students spend a week on the campus of UC Irvine participating in Earth System Science lectures, laboratory activities, and tours. The science curriculum is closely woven together with cultural activities, native studies, and communication skills programs The program culminates with a closing ceremony during which students present poster projects on environmental issues relevant to their tribal communities. The inaugural AISESS program took place from July 15th-28th, 2012. We received over 100 applications from Native American high school students from across the nation. We accepted 40 students for the first year, of which 34 attended the program. The

  2. The rise and rise of renewable cities

    Directory of Open Access Journals (Sweden)

    Newman Peter

    2017-01-01

    Full Text Available The decoupling of fossil fuels from growth in economic activity has been proceeding rapidly for most of the 21st century and is analysed globally in terms of structures and technologies for energy efficiency and for switching to renewable energy in the world’s cities. This is leading to the decline of coal and oil. The evidence suggests that the changes are based on demand for the structures and technologies that are emerging, facilitating a disruptive process. The rise of renewable cities can therefore be expected to accelerate.

  3. 'Nothing works' in secure residential youth care?

    NARCIS (Netherlands)

    Souverein, F.A.; van der Helm, G.H.P.; Stams, G.J.J.M.

    2013-01-01

    A debate about the effectiveness of secure residential youth care is currently going on. While some continue to support secure residential youth care, others conclude that ‘nothing works’ in secure residential youth care, and argue that non-residential treatment is superior to secure residential

  4. A waterborne outbreak and detection of cryptosporidium oocysts in drinking water of an older high-rise apartment complex in seoul.

    Science.gov (United States)

    Cho, Eun-Joo; Yang, Jin-Young; Lee, Eun-Sook; Kim, Se-Chul; Cha, So-Yang; Kim, Sung-Tek; Lee, Man-Ho; Han, Sun-Hee; Park, Young-Sang

    2013-08-01

    From May to June 2012, a waterborne outbreak of 124 cases of cryptosporidiosis occurred in the plumbing systems of an older high-rise apartment complex in Seoul, Republic of Korea. The residents of this apartment complex had symptoms of watery diarrhea and vomiting. Tap water samples in the apartment complex and its adjacent buildings were collected and tested for 57 parameters under the Korean Drinking Water Standards and for additional 11 microbiological parameters. The microbiological parameters included total colony counts, Clostridium perfringens, Enterococcus, fecal streptococcus, Salmonella, Shigella, Pseudomonas aeruginosa, Cryptosporidium oocysts, Giardia cysts, total culturable viruses, and Norovirus. While the tap water samples of the adjacent buildings complied with the Korean Drinking Water Standards for all parameters, fecal bacteria and Cryptosporidium oocysts were detected in the tap water samples of the outbreak apartment complex. It turned out that the agent of the disease was Cryptosporidium parvum. The drinking water was polluted with sewage from a septic tank in the apartment complex. To remove C. parvum oocysts, we conducted physical processes of cleaning the water storage tanks, flushing the indoor pipes, and replacing old pipes with new ones. Finally we restored the clean drinking water to the apartment complex after identification of no oocysts.

  5. Response Analysis and Auto-Regressive Exogenous Modeling of a Steel-Reinforced Concrete High-Rise Building during the 2011 Off the Pacific Coast of Tohoku Earthquake

    Directory of Open Access Journals (Sweden)

    Naohiro Nakamura

    2017-12-01

    Full Text Available Many seismic records were obtained during the 2011 off the Pacific coast of Tohoku earthquake. These records can be used to improve the seismic design and disaster prevention capabilities of buildings. In this paper, seismic simulation analyses of a steel-reinforced concrete high-rise building located in the Tokyo Bay area are conducted based on the seismic record of the Tohoku earthquake. A non-linear sway-rocking model is used in the analysis, and comparisons are drawn between the observed records and analytical results of the pre-shock, main shock, and earthquake after 1 month. The analytical results correspond well with the seismic records, and the effect of the non-linear nature of the main shock is retained in the building. This is an important consideration when conducting response evaluation. An auto-regressive exogenous model is used to identify the first and second natural periods, and the damping ratios, of both the records and the analytical results. Although the first and second damping ratios are similar in value to the observed results, the second damping ratio is overestimated in the analytical results because of the stiffness damping model.

  6. Historical Consumption of Heating Natural Gas and Thermal Monitoring of a Multifamily High-Rise Building in a Temperate/Cold Climate in Argentina

    Directory of Open Access Journals (Sweden)

    Celina Filippín

    2012-12-01

    Full Text Available This paper analyzes the historical consumption of natural gas in a multifamily high-rise building and the monitored winter thermal behavior of an apartment sample. The building is located in the center of Argentina (latitude: 36º27’S; longitude: 64º27’W, where the climate is a cold temperate with an absolute minimum temperature that may reach −10 °C. The building has two blocks, North and South. The building’s annual gas consumption and its variability between 1996 and 2008 are shown. The South block consumed 78% more gas, a situation expected due to lower solar resource availability and greater vulnerability regarding strong and cold SW winds. Indoor temperatures monitored during 2009 in four apartments are described. The outdoor minimum temperature reached −5 °C, with solar irradiance around 500 W/m2 at midday. Results showed that the average indoor temperatures were 20.1, 20.6, 24.0 and 22.1 °C. The highest consumption value corresponded to the apartment exposed to SW cold winds. Compared to the rest of the building, the apartment on the top floor consumes 59% more energy than the average for the gas consumed throughout the year. The authors assume that the energy potentials of intervention are different, and not necessarily all the apartments should have the same technological response.

  7. Numerical Investigation of Wind Conditions for Roof-Mounted Wind Turbines: Effects of Wind Direction and Horizontal Aspect Ratio of a High-Rise Cuboid Building

    Directory of Open Access Journals (Sweden)

    Takaaki Kono

    2016-11-01

    Full Text Available From the viewpoint of installing small wind turbines (SWTs on rooftops, this study investigated the effects of wind direction and horizontal aspect ratio (HAR = width/length of a high-rise cuboid building on wind conditions above the roof by conducting large eddy simulations (LESs. The LES results confirmed that as HAR decreases (i.e., as the building width decreases, the variation in wind velocity over the roof tends to decrease. This tendency is more prominent as the angle between the wind direction and the normal vector of the building’s leeward face with longer roof edge increases. Moreover, at windward corners of the roof, wind conditions are generally favorable at relatively low heights. In contrast, at the midpoint of the roof's windward edge, wind conditions are generally not favorable at relatively low heights. At leeward representative locations of the roof, the bottoms of the height range of favorable wind conditions are typically higher than those at the windward representative locations, but the favorable wind conditions are much better at the leeward representative locations. When there is no prevailing wind direction, the center of the roof is more favorable for installing SWTs than the corners or the edge midpoints of the roof.

  8. Measurement of radio wave reflection due to temperature rising from rock salt and ice irradiated by an electron beam for an ultra-high-energy neutrino detector

    Energy Technology Data Exchange (ETDEWEB)

    Tanikawa, Takahiro; Chiba, Masami; Kamijo, Toshio; Yabuki, Fumiaki; Yasuda, Osamu; Akiyama, Hidetoshi; Chikashige, Yuichi; Kon, Tadashi; Shimizu, Yutaka; Utsumi, Michiaki; Fujii, Masatoshi [Graduate School of Science and Engineering, Tokyo Metropolitan University, 1-1 Minami-Ohsawa, Hachioji-shi, Tokyo 192-0397 (Japan); Faculty of Science and Technology, Seikei University, Musashino-shi, Tokyo 180-8633 (Japan); Department of Applied Science and Energy Engineering, School of Engineering, Tokai University, Hiratsuka-shi, Kanagawa 259-1292 (Japan); School of Medicine, Shimane University, Izumo-shi, Shimane 693-8501 (Japan)

    2012-11-12

    An ultra-high-energy neutrino (UHE{nu}) gives temperature rise along the hadronic and electromagnetic shower when it enters into rock salt or ice. Permittivities of them arise with respect the temperatures at ionization processes of the UHE{nu} shower. It is expected by Fresnel's formula that radio wave reflects at the irregularity of the permittivity in the medium. We had found the radio wave reflection effect in rock salt. The reflection effect and long attenuation length of radio wave in rock salt and ice would yield a new UHE{nu} detection method. An experiment for ice was performed to study the reflection effect. A coaxial tube was filled with rock salt powder or ice. Open end of the coaxial tube was irradiated by a 2 MeV electron beam. Radio wave of 435 MHz was introduced to the coaxial tube. We measured the reflection wave from the open end. We found the radio wave reflection effect due to electron beam irradiation in ice as well as in rock salt.

  9. Evaluation of the dynamic responses of high rise buildings with respect to the direct methods for soil-foundation-structure interaction effects and comparison with the approximate methods

    Directory of Open Access Journals (Sweden)

    Jahangir Khazaei

    2017-08-01

    Full Text Available In dynamic analysis, modeling of soil medium is ignored because of the infinity and complexity of the soil behavior and so the important effects of these terms are neglected, while the behavior of the soil under the structure plays an important role in the response of the structure during an earthquake. In fact, the soil layers and soil foundation structure interaction phenomena can increase the applied seismic forces during earthquakes that has been examined with different methods. In this paper, effects of soil foundation structure interaction on a steel high rise building has been modeled using Abaqus software for nonlinear dynamic analysis with finite element direct method and simulation of infinite boundary condition for soil medium and also approximate Cone model. In the direct method, soil, structure and foundation are modeled altogether. In other hand, for using Cone model as a simple model, dynamic stiffness coefficients have been employed to simulate soil with considering springs and dashpots in all degree of freedom. The results show that considering soil foundation structure interaction cause increase in maximum lateral displacement of structure and the friction coefficient of soil-foundation interface can alter the responses of structure. It was also observed that the results of the approximate methods have good agreement for engineering demands.

  10. Evaluating the physical demands on firefighters using track-type stair descent devices to evacuate mobility-limited occupants from high-rise buildings.

    Science.gov (United States)

    Mehta, Jay P; Lavender, Steven A; Hedman, Glenn E; Reichelt, Paul A; Park, Sanghyun; Conrad, Karen M

    2015-01-01

    The physical demands on firefighting personnel were investigated when using different types of track-type stair descent devices designed for the emergency evacuation of high rise buildings as a function of staircase width and evacuation urgency. Twelve firefighters used five track-type stair descent devices during simulated urgent and non-urgent evacuations. The devices were evaluated under two staircase width conditions (1.12, and 1.32 m), and three devices were also evaluated under a narrower staircase condition (0.91 m). Dependent measures included electromyographic (EMG) data, spine motion, heart rates, Borg Scale ratings, task durations and descent velocities. Stair descent speeds favored the devices that had shorter fore/aft dimensions when moving through the landing. EMG results indicated that there were tradeoffs due to design features, particularly on the landings where the physical demands tended to be greater. On the landings, devices that could be rolled on four wheels reduced the deltoid and bicep activation levels. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  11. Evaluating the physical demands on firefighters using hand-carried stair descent devices to evacuate mobility-limited occupants from high-rise buildings.

    Science.gov (United States)

    Lavender, Steven A; Hedman, Glenn E; Mehta, Jay P; Reichelt, Paul A; Conrad, Karen M; Park, Sanghyun

    2014-05-01

    The physical demands on firefighting personnel were investigated when using different types of hand-carried stair descent devices designed for the emergency evacuation of high rise buildings as a function of staircase width and evacuation urgency. Twelve firefighters used three hand-carried stair descent devices during simulated urgent and non-urgent evacuations. The devices were evaluated under three staircase width conditions (0.91, 1.12, and 1.32 m). For comparison, an urgent manual carry was also performed on the 1.12 m wide stairs. Dependent measures included electromyographic (EMG) data, heart rates, Borg Scale ratings, task durations and descent velocities. Results indicated that the stair chair with extended front handles, which allows the front person to descend the stairs facing forward, reduced the time integrated back muscle EMG by half and showed a descent velocity that was 1.8 times faster than the other stair descent devices in the study. There were no differences across staircase widths. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  12. High-resolution U-Pb ages from the Upper Triassic Chinle Formation (New Mexico, USA) support a diachronous rise of dinosaurs

    Science.gov (United States)

    Irmis, Randall B.; Mundil, Roland; Martz, Jeffrey W.; Parker, William G.

    2011-09-01

    Though the Late Triassic preserves major paleoenvironmental fluctuations and is key for understanding the evolution of Mesozoic and modern terrestrial ecosystems, comparisons of Late Triassic non-marine sedimentary and fossil records are difficult because global correlations lack precise radioisotopic ages, and have instead been based upon unconstrained biostratigraphic ranges of palynomorph and vertebrate fossils. The Chinle Formation in southwestern North America preserves a major Late Triassic record of paleoenvironmental and biotic change, including significant early dinosaur fossils. Previous high-resolution radioisotopic age constraints for the formation are limited to a single U-Pb zircon age from the upper third of the formation. The extraction of a geologically meaningful age is challenging from these redeposited units and preference is given to considering the youngest age of a deposit as a maximum age and closest approximation of the depositional age. Because calculating a weighted mean age (or median age) from a group of ages from such deposits is often not adequate, the precision of our two new CA-TIMS single crystal zircon U-Pb ages from the Chinle Formation of New Mexico is limited to ca 0.3% (or ± 0.7 Ma) of the youngest crystal age. Our 206Pb/ 238U age of ~ 218 Ma from the Blue Mesa Member in Six Mile Canyon, western New Mexico, demonstrates that strata, palynomorphs, and vertebrate fossils previously considered to be late Carnian in age are actually middle Norian in age. Our new age of ~ 212 Ma from the Hayden Quarry within the Petrified Forest Member at Ghost Ranch, northern New Mexico, provides the first maximum age for important vertebrate assemblages from this area that record the rise of dinosaurs, and demonstrates that basal dinosauromorphs ('dinosaur precursors') co-existed with dinosaurs for at least 18 Ma. These new radioisotopic data allow a new correlation of the Chinle Formation to the Late Triassic timescale, suggesting that most if

  13. Development of a Residential Integrated Ventilation Controller

    Energy Technology Data Exchange (ETDEWEB)

    Staff Scientist; Walker, Iain; Sherman, Max; Dickerhoff, Darryl

    2011-12-01

    The goal of this study was to develop a Residential Integrated Ventilation Controller (RIVEC) to reduce the energy impact of required mechanical ventilation by 20percent, maintain or improve indoor air quality and provide demand response benefits. This represents potential energy savings of about 140 GWh of electricity and 83 million therms of natural gas as well as proportional peak savings in California. The RIVEC controller is intended to meet the 2008 Title 24 requirements for residential ventilation as well as taking into account the issues of outdoor conditions, other ventilation devices (including economizers), peak demand concerns and occupant preferences. The controller is designed to manage all the residential ventilation systems that are currently available. A key innovation in this controller is the ability to implement the concept of efficacy and intermittent ventilation which allows time shifting of ventilation. Using this approach ventilation can be shifted away from times of high cost or high outdoor pollution towards times when it is cheaper and more effective. Simulations, based on the ones used to develop the new residential ventilation requirements for the California Buildings Energy code, were used to further define the specific criteria and strategies needed for the controller. These simulations provide estimates of the energy, peak power and contaminant improvement possible for different California climates for the various ventilation systems. Results from a field test of the prototype controller corroborate the predicted performance.

  14. Re-thinking residential mobility

    Science.gov (United States)

    van Ham, Maarten; Findlay, Allan M.

    2015-01-01

    While researchers are increasingly re-conceptualizing international migration, far less attention has been devoted to re-thinking short-distance residential mobility and immobility. In this paper we harness the life course approach to propose a new conceptual framework for residential mobility research. We contend that residential mobility and immobility should be re-conceptualized as relational practices that link lives through time and space while connecting people to structural conditions. Re-thinking and re-assessing residential mobility by exploiting new developments in longitudinal analysis will allow geographers to understand, critique and address pressing societal challenges. PMID:27330243

  15. Large-Scale Residential Demolition

    Science.gov (United States)

    The EPA provides resources for handling residential demolitions or renovations. This includes planning, handling harmful materials, recycling, funding, compliance assistance, good practices and regulations.

  16. Emission factors and characteristics of ammonia, hydrogen sulfide, carbon dioxide, and particulate matter at two high-rise layer hen houses

    Science.gov (United States)

    Ni, Ji-Qin; Liu, Shule; Diehl, Claude A.; Lim, Teng-Teeh; Bogan, Bill W.; Chen, Lide; Chai, Lilong; Wang, Kaiying; Heber, Albert J.

    2017-04-01

    Air pollutants emitted from confined animal buildings can cause environmental pollution and ecological damage. Long-term (>6 months) and continuous (or high frequency) monitoring that can reveal seasonal and diurnal variations is needed to obtain emission factors and characteristics about these pollutants. A two-year continuous monitoring of ammonia (NH3), hydrogen sulfide (H2S), carbon dioxide (CO2) and particulate matter (PM10) emissions from two 218,000-hen high-rise layer houses (H-A and H-B) in Indiana, USA was conducted from June 2007 to May 2009. Gaseous pollutant concentrations were measured with two gas analyzers and PM10 concentrations were measured with three Tapered Element Oscillating Microbalances. The operation and performance of ventilation fans were continuously monitored with multiple methods. Only the emission rates calculated with valid data days (days with more than 18 h, or 75%, of valid data) are reported in this paper. The two-house and two-year mean ± standard deviation emissions per day per hen for NH3, H2S, CO2, and PM10 were 1.08 ± 0.42 g, 1.37 ± 0.83 mg, 76.7 ± 14.6 g, and 20.6 ± 22.5 mg, respectively. Seasonal emission variations were demonstrated for NH3 and CO2, but not evident for H2S and PM10. Ammonia and CO2 emissions were higher in winter than in summer. Significant daily mean emission variations were observed for all four pollutants between the two houses (P 9% of that from bird respiration. Emissions of CO2 during molting were about 80% of those during normal egg production days. Emissions of H2S were not a major concern due to their very low quantities. Emissions of PM10 were more variable than other pollutants. However, not all of the emission statistics are explainable.

  17. A Reduced-Order Controller Considering High-Order Modal Information of High-Rise Buildings for AMD Control System with Time-Delay

    Directory of Open Access Journals (Sweden)

    Zuo-Hua Li

    2017-01-01

    Full Text Available Time-delays of control force calculation, data acquisition, and actuator response will degrade the performance of Active Mass Damper (AMD control systems. To reduce the influence, model reduction method is used to deal with the original controlled structure. However, during the procedure, the related hierarchy information of small eigenvalues will be directly discorded. As a result, the reduced-order model ignores the information of high-order mode, which will reduce the design accuracy of an AMD control system. In this paper, a new reduced-order controller based on the improved Balanced Truncation (BT method is designed to reduce the calculation time and to retain the abandoned high-order modal information. It includes high-order natural frequency, damping ratio, and vibration modal information of the original structure. Then, a control gain design method based on Guaranteed Cost Control (GCC algorithm is presented to eliminate the adverse effects of data acquisition and actuator response time-delays in the design process of the reduced-order controller. To verify its effectiveness, the proposed methodology is applied to a numerical example of a ten-storey frame and an experiment of a single-span four-storey steel frame. Both numerical and experimental results demonstrate that the reduced-order controller with GCC algorithm has an excellent control effect; meanwhile it can compensate time-delays effectively.

  18. ASHRAE and residential ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.

    2003-10-01

    In the last quarter of a century, the western world has become increasingly aware of environmental threats to health and safety. During this period, people psychologically retreated away from outdoors hazards such as pesticides, smog, lead, oil spills, and dioxin to the seeming security of their homes. However, the indoor environment may not be healthier than the outdoor environment, as has become more apparent over the past few years with issues such as mold, formaldehyde, and sick-building syndrome. While the built human environment has changed substantially over the past 10,000 years, human biology has not; poor indoor air quality creates health risks and can be uncomfortable. The human race has found, over time, that it is essential to manage the indoor environments of their homes. ASHRAE has long been in the business of ventilation, but most of the focus of that effort has been in the area of commercial and institutional buildings. Residential ventilation was traditionally not a major concern because it was felt that, between operable windows and envelope leakage, people were getting enough outside air in their homes. In the quarter of a century since the first oil shock, houses have gotten much more energy efficient. At the same time, the kinds of materials and functions in houses changed in character in response to people's needs. People became more environmentally conscious and aware not only about the resources they were consuming but about the environment in which they lived. All of these factors contributed to an increasing level of public concern about residential indoor air quality and ventilation. Where once there was an easy feeling about the residential indoor environment, there is now a desire to define levels of acceptability and performance. Many institutions--both public and private--have interests in Indoor Air Quality (IAQ), but ASHRAE, as the professional society that has had ventilation as part of its mission for over 100 years, is the

  19. Prismatic louver active façades for natural illumination and thermal energy gain in high-rise and commercial buildings

    Science.gov (United States)

    Vlachokostas, A.; Volkmann, C.; Madamopoulos, N.

    2013-06-01

    High-rise and commercial buildings in urban centers present a great challenge in terms of their energy consumption. Due to maximization of rentable square footage, the preferred urban façade system over the past 50 years has been the "curtain wall", only a few inches thick and comprised of modular steel or aluminum framing and predominant glass infills. The perceived Achilles heel of these modern glass façade systems is their thermal inefficiency: They are inadequate thermal barriers and exhibit excessive solar gain. The excessive solar gain has a negative impact on lighting and cooling loads of the entire building. This negative impact will be further exacerbated with rising energy costs. However, rather than view the glass façade's uncontrolled solar gain merely as a weakness contributing to higher energy consumption, the condition could indeed be considered as related to an energy solution. These glass façades can be retrofitted to operate as a provider of daylight and energy for the rest of the building, taking advantage of the overexposure to the sun. With today's technology, the sun's abundant renewable energy can be the driving force for the energy transition of these building envelopes. Illumination, thermal energy, and electricity production can be directly supplied from the sun, and when correctly and efficiently managed, they can lead to a significantly less energy-intensive building stock. We propose a multi-purpose, prismatic, louver-based façade to perform both daylight and thermal energy harvesting with a goal of offering a better daylight environment for the occupants, and reduce the energy consumption and carbon footprint of the building. While decentralized air-conditioning units are commonly accepted as façade "plug-ins", such decentralization could be utilized with more benefits by passively managing the interior space conditions, without using any extra power. Just as living organisms respond and adapt to the environmental changes in

  20. Thermal environmental case study of an existing underfloor air distribution (UFAD) system in a high-rise building in the tropics

    Science.gov (United States)

    Ya, Y. H.; Poh, K. S.

    2015-09-01

    The performance of an existing underfloor air distribution (UFAD) system in a renowned high-rise office tower in Malaysia was studied to identify the root cause issues behind the poor indoor air quality. Occupants are the best thermal sensor. The building was detected with the sick building syndrome (SBS) that causes runny noses, flu-like symptoms, irritated skin, and etc. Long period of exposure to indoor air pollutants may increase the occupant's health risk. The parameters such as the space temperature, relative humidity, air movement, air change, fresh air flow rate, chilled water supply and return are evaluated at three stories that consist of five open offices. A full traverse study was carried out at one of the fresh air duct. A simplified duct flow measurement method using pitot-tubes was developed. The results showed that the diffusers were not effective in creating the swirl effect to the space. Internal heat gain from human and office electrical equipment were not drawn out effectively. Besides, relative humidity has exceeded the recommended level. These issues were caused by the poor maintenance of the building. The energy efficiency strategy of the UFAD system comes from the higher supply air temperature. It may leads to insufficient cooling load for the latent heat gained under improper system performance. Special care and considerations in design, construction and maintenance are needed to ensure the indoor air quality to be maintained. Several improvements were recommended to tackle the existing indoor air quality issues. Solar system was studied as one of the innovative method for retrofitting.

  1. A study on the development and application of the E/V shaft cooling system to reduce stack effect in high-rise buildings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joonghoon [Institute of Technology, Samsung C and T Corporation, Seoul (Korea); Song, Doosam [Dept. of Architectural Eng., Sungkyunkwan University, Suwon, Gyeongg-Do (Korea); Park, Dongryul [Graduate School, Sungkyunkwan University, Suwon, Gyeongg-Do (Korea)

    2010-02-15

    This study suggests the E/V(Elevator) shaft cooling system as a new approach to reduce the stack effect and the related problems in high-rise buildings. The basic characteristics on its application were analyzed with some simulations in this study. Moreover, the system was applied to an actual building and its performance was evaluated through the measurements. The system can reduce the stack effect itself and the related problems simultaneously and it can reduce the pressure and the air flow rate in each part of a building in the same ratio. These features were shown in the results of the simulations; for the examples, when all the E/V shafts were cooled from 22 C to 12 C, the stack effect and the pressure in each part of the modeled building were decreased by about 27%. In the field measurements, the wind velocity through the E/V door was decreased effectively in the whole building; its reduction ratio at the lobby floor was about 25% and at the upper floors (37F, 38F) about 10% respectively. But, the neutral pressure level at the E/V shaft was moved by the vertical temperature difference in the E/V shaft because of the inflow ducts concentrated in the lower part of the E/V shaft. This movement was also shown in another simulation on the same conditions as the measured ones. It is very important to minimize the vertical temperature difference in the E/V shaft to maximize the reduction effects on the problems. (author)

  2. Active mass damper system for high-rise buildings using neural oscillator and position controller considering stroke limitation of the auxiliary mass

    Science.gov (United States)

    Hongu, J.; Iba, D.; Nakamura, M.; Moriwaki, I.

    2016-04-01

    This paper proposes a problem-solving method for the stroke limitation problem, which is related to auxiliary masses of active mass damper systems for high-rise buildings. The proposed method is used in a new simple control system for the active mass dampers mimicking the motion of bipedal mammals, which has a neural oscillator synchronizing with the acceleration response of structures and a position controller. In the system, the travel distance and direction of the auxiliary mass of the active mass damper is determined by reference to the output of the neural oscillator, and then, the auxiliary mass is transferred to the decided location by using a PID controller. The one of the purpose of the previouslyproposed system is stroke restriction problem avoidance of the auxiliary mass during large earthquakes by the determination of the desired value within the stroke limitation of the auxiliary mass. However, only applying the limited desired value could not rigorously restrict the auxiliary mass within the limitation, because the excessive inertia force except for the control force produced by the position controller affected on the motion of the auxiliary mass. In order to eliminate the effect on the auxiliary mass by the structural absolute acceleration, a cancellation method is introduced by adding a term to the control force of the position controller. We first develop the previously-proposed system for the active mass damper and the additional term for cancellation, and verity through numerical experiments that the new system is able to operate the auxiliary mass within the restriction during large earthquakes. Based on the comparison of the proposed system with the LQ system, a conclusion was drawn regarding which the proposed neuronal system with the additional term appears to be able to limit the stroke of the auxiliary mass of the AMD.

  3. Residential Mechanical Precooling

    Energy Technology Data Exchange (ETDEWEB)

    German, Alea [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation (ARBI); Hoeschele, Marc [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation (ARBI)

    2014-12-01

    Residential air conditioning (AC) represents a challenging load for many electric utilities with poor load factors. Mechanical precooling improves the load factor by shifting cooling operation from on-peak to off-peak hours. This provides benefits to utilities and the electricity grid, as well as to occupants who can take advantage of time-of-use (TOU) electricity rates. Performance benefits stem from reduced compressor cycling, and shifting condensing unit operation to earlier periods of the day when outdoor temperatures are more favorable to operational efficiency. Finding solutions that save energy and reduce demand on the electricity grid is an important national objective and supports key Building America goals. The Alliance for Residential Building Innovation team evaluated mechanical AC precooling strategies in homes throughout the United States. EnergyPlus modeling was used to evaluate two homes with different performance characteristics in seven climates. Results are applicable to new construction homes and most existing homes built in the last 10 years, as well as fairly efficient retrofitted homes. A successful off-peak AC strategy offers the potential for increased efficiency and improved occupant comfort, and promotes a more reliable and robust electricity grid. Demand response capabilities and further integration with photovoltaic TOU generation patterns provide additional opportunities to flatten loads and optimize grid impacts.

  4. Residential fuel quality

    Energy Technology Data Exchange (ETDEWEB)

    Santa, T. [Santa Fuel, Inc., Bridgeport, CT (United States)

    1997-09-01

    This report details progress made in improving the performance of No. 2 heating oil in residential applications. Previous research in this area is documented in papers published in the Brookhaven Oil Heat Technology Conference Proceedings in 1993, 1994 and 1996. By way of review we have investigated a number of variables in the search for improved fuel system performance. These include the effect of various additives designed to address stability, dispersion, biotics, corrosion and reaction with metals. We have also investigated delivery methods, filtration, piping arrangements and the influence of storage tank size and location. As a result of this work Santa Fuel Inc. in conjunction with Mobile Oil Corporation have identified an additive package which shows strong evidence of dramatically reducing the occurrence of fuel system failures in residential oil burners. In a broad market roll-out of the additized product we have experienced a 29% reduction in fuel related service calls when comparing the 5 months ending January 1997 to the same period ending January 1996.

  5. Congestion and residential moving behaviour

    DEFF Research Database (Denmark)

    Larsen, Morten Marott; Pilegaard, Ninette; Van Ommeren, Jos

    2008-01-01

    we study how congestion and residential moving behaviour are interrelated, using a two-region job search model. Workers choose between interregional commuting and residential moving, in order to live closer to their place of work. This choice affects the external costs of commuting, due to conges...

  6. Evaluation of Multi Residential House Renovation Efficiency

    National Research Council Canada - National Science Library

    Daiva Rapcevičienė

    2011-01-01

    .... According to reconstruction investments of multi residential house, three government financing programs of multi residential house are evaluated and selected the most effective program by comparing...

  7. Precipitation Mediates the Response of Carbon Cycle to Rising Temperature in the Mid-to-High Latitudes of the Northern Hemisphere.

    Directory of Open Access Journals (Sweden)

    Xin Lin

    Full Text Available Over the past decades, rising air temperature has been accompanied by changes in precipitation. Despite relatively robust literature on the temperature sensitivity of carbon cycle at continental to global scales, less is known about the way this sensitivity is affected by precipitation. In this study we investigate how precipitation mediates the response of the carbon cycle to warming over the mid-to-high latitudes in the Northern Hemisphere (north of 30 °N. Based on atmospheric CO2 observations at Point Barrow (BRW in Alaska, satellite-derived NDVI (a proxy of vegetation productivity, and temperature and precipitation data, we analyzed the responses of carbon cycle to temperature change in wet and dry years (with precipitation above or below the multiyear average. The results suggest that, over the past three decades, the net seasonal atmospheric CO2 changes at BRW were significantly correlated with temperature in spring and autumn, yet only weakly correlated with temperature and precipitation during the growing season. We further found that responses of the net CO2 changes to warming in spring and autumn vary with precipitation levels, with the absolute temperature sensitivity in wet years roughly twice that in dry years. The analyses of NDVI and climate data also identify higher sensitivity of vegetation growth to warming in wet years for the growing season, spring and summer. The different temperature sensitivities in wet versus dry years probably result from differences in soil moisture and/or nutrient availability, which may enhance (inhibit the responsiveness of carbon assimilation and/or decomposition to warming under high (low precipitation levels. The precipitation-mediated response of the terrestrial carbon cycle to warming reported here emphasizes the important role of precipitation in assessing the temporal variations of carbon budgets in the past as well as in the future. More efforts are required to reduce uncertainty in future

  8. Precipitation Mediates the Response of Carbon Cycle to Rising Temperature in the Mid-to-High Latitudes of the Northern Hemisphere.

    Science.gov (United States)

    Lin, Xin; Li, Junsheng; Luo, Jianwu; Wu, Xiaopu; Tian, Yu; Wang, Wei

    2015-01-01

    Over the past decades, rising air temperature has been accompanied by changes in precipitation. Despite relatively robust literature on the temperature sensitivity of carbon cycle at continental to global scales, less is known about the way this sensitivity is affected by precipitation. In this study we investigate how precipitation mediates the response of the carbon cycle to warming over the mid-to-high latitudes in the Northern Hemisphere (north of 30 °N). Based on atmospheric CO2 observations at Point Barrow (BRW) in Alaska, satellite-derived NDVI (a proxy of vegetation productivity), and temperature and precipitation data, we analyzed the responses of carbon cycle to temperature change in wet and dry years (with precipitation above or below the multiyear average). The results suggest that, over the past three decades, the net seasonal atmospheric CO2 changes at BRW were significantly correlated with temperature in spring and autumn, yet only weakly correlated with temperature and precipitation during the growing season. We further found that responses of the net CO2 changes to warming in spring and autumn vary with precipitation levels, with the absolute temperature sensitivity in wet years roughly twice that in dry years. The analyses of NDVI and climate data also identify higher sensitivity of vegetation growth to warming in wet years for the growing season, spring and summer. The different temperature sensitivities in wet versus dry years probably result from differences in soil moisture and/or nutrient availability, which may enhance (inhibit) the responsiveness of carbon assimilation and/or decomposition to warming under high (low) precipitation levels. The precipitation-mediated response of the terrestrial carbon cycle to warming reported here emphasizes the important role of precipitation in assessing the temporal variations of carbon budgets in the past as well as in the future. More efforts are required to reduce uncertainty in future precipitation

  9. Modeling and optimization of a heat-pump-assisted high temperature proton exchange membrane fuel cell micro-combined-heat-and-power system for residential applications

    DEFF Research Database (Denmark)

    Arsalis, Alexandros; Kær, Søren Knudsen; Nielsen, Mads Pagh

    2015-01-01

    In this study a micro-combined-heat-and-power (micro-CHP) system is coupled to a vapor-compression heat pump to fulfill the residential needs for heating (space heating and water heating) and electricity in detached single-family households in Denmark. Such a combination is assumed to be attractive...... for application, since both fuel cell technology and electric heat pumps are found to be two of the most efficient technologies for generation/conversion of useful energy. The micro-CHP system is fueled with natural gas and includes a fuel cell stack, a fuel processor and other auxiliary components. The micro....... The variational loads are considered from full to quarter load, and the micro-CHP system is optimized in terms of operating thermophysical parameters for every different load. The results clearly indicate the capability of the proposed system to perform efficiently throughout all necessary load changes to fulfill...

  10. Environmental Psychological Assessment for High-rise Residents in Bangkok Metropolitan Area: Safety Concern, Privacy Satisfaction, and Sense of Community : Een ruimtelijke en psychologische beoordeling voor hoogbouwbewoners in de metropoolregio Bangkok: veiligheidszorgen, privacyborging en gemeenschapszin

    NARCIS (Netherlands)

    S. Rujibhong (Siriwan)

    2017-01-01

    markdownabstractDue to a large population size and spatial limitations of urban environments, the vertical expansion of city space including high-rise habitat has become an inevitable pathway for the metropolises all over the world. Likewise, Bangkok, the capital city of Thailand and one of the most

  11. Residential Energy Performance Metrics

    Directory of Open Access Journals (Sweden)

    Christopher Wright

    2010-06-01

    Full Text Available Techniques for residential energy monitoring are an emerging field that is currently drawing significant attention. This paper is a description of the current efforts to monitor and compare the performance of three solar powered homes built at Missouri University of Science and Technology. The homes are outfitted with an array of sensors and a data logger system to measure and record electricity production, system energy use, internal home temperature and humidity, hot water production, and exterior ambient conditions the houses are experiencing. Data is being collected to measure the performance of the houses, compare to energy modeling programs, design and develop cost effective sensor systems for energy monitoring, and produce a cost effective home control system.

  12. Residential energy performance metrics

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Ch. [Department of Engineering Management, Missouri University of Science and Technology, 600 W. 14th Street, Rolla, MO 65409 (United States); Baur, S. [Department of Civil, Architectural and Environmental Engineering, Missouri University of Science and Technology, 1401 Pine Street, Rolla, MO 65409 (United States); Grantham, K. [Department of Engineering Management, Missouri University of Science and Technology, 600 W. 14th Street, Rolla, MO 65409 (United States); Stone, R. B. [School of Mechanical, Industrial, and Manufacturing Engineering, Oregon State University, Corvallis, OR, 97331(United States); Grasman, S. E. [Department of Engineering Management, Missouri University of Science and Technology, 600 W. 14th Street, Rolla, MO 65409 (United States)

    2010-06-15

    Techniques for residential energy monitoring are an emerging field that is currently drawing significant attention. This paper is a description of the current efforts to monitor and compare the performance of three solar powered homes built at Missouri University of Science and Technology. The homes are outfitted with an array of sensors and a data logger system to measure and record electricity production, system energy use, internal home temperature and humidity, hot water production, and exterior ambient conditions the houses are experiencing. Data is being collected to measure the performance of the houses, compare to energy modeling programs, design and develop cost effective sensor systems for energy monitoring, and produce a cost effective home control system. (authors)

  13. College residential sleep environment.

    Science.gov (United States)

    Sexton-Radek, Kathy; Hartley, Andrew

    2013-12-01

    College students regularly report increased sleep disturbances as well as concomitant reductions in performance (e.g., academic grades) upon entering college. Sleep hygiene refers to healthy sleep practices that are commonly used as first interventions in sleep disturbances. One widely used practice of this sort involves arranging the sleep environment to minimize disturbances from excessive noise and light at bedtime. Communal sleep situations such as those in college residence halls do not easily support this intervention. Following several focus groups, a questionnaire was designed to gather self-reported information on sleep disturbances in a college population. The present study used The Young Adult Sleep Environment Inventory (YASEI) and sleep logs to investigate the sleep environment of college students living in residential halls. A summary of responses indicated that noise and light are significant sleep disturbances in these environments. Recommendations are presented related to these findings.

  14. Solar Energy Systems for Ohioan Residential Homeowners

    Science.gov (United States)

    Luckett, Rickey D.

    Dwindling nonrenewable energy resources and rising energy costs have forced the United States to develop alternative renewable energy sources. The United States' solar energy industry has seen an upsurge in recent years, and photovoltaic holds considerable promise as a renewable energy technology. The purpose of this case study was to explore homeowner's awareness of the benefits of solar energy. Disruptive-innovation theory was used to explore marketing strategies for conveying information to homeowners about access to new solar energy products and services. Twenty residential homeowners were interviewed face-to-face to explore (a) perceived benefits of solar energy in their county in Ohio, and (b) perceptions on the rationale behind the marketing strategy of solar energy systems sold for residential use. The study findings used inductive analyses and coding interpretation to explore the participants' responses that revealed 3 themes: the existence of environmental benefits for using solar energy systems, the expensive cost of equipment associated with government incentives, and the lack of marketing information that is available for consumer use. The implications for positive social change include the potential to enable corporate leaders, small business owners, and entrepreneurs to develop marketing strategies for renewable energy systems. These strategies may promote use of solar energy systems as a clean, renewable, and affordable alternative electricity energy source for the 21st century.

  15. The Rise of Iran

    DEFF Research Database (Denmark)

    Jakobsen, Peter Viggo; Rahigh-Aghsan, Ali

    2010-01-01

    Iran is viewed by many as a rising power that poses an increasing threat to regional and even global security. This view is wrong for three reasons. Iran's hard and soft power is exaggerated by most accounts; it is too limited to allow the Iranians to dominate the Persian Gulf let alone the Middl...... regional powers and the West to balance Iran and contain its influence, even if it acquires nuclear weapons. If these limitations on Iranian power are taken into account the rise seems destined to be a short one....... East, and its brand of Shi‘ism has very limited appeal outside of Iran. Second, growing internal political and economic instability will seriously limit Iran's bid for regional dominance. Third, the failure to stop the Iranian nuclear program has led analysts to underestimate the ability of the other...

  16. The Rise of Iran

    DEFF Research Database (Denmark)

    Rahigh-Aghsan, Ali; Jakobsen, Peter Viggo

    2010-01-01

    Iran is viewed as a rising power that poses an increasing threat to regional and even global security. This view is wrong for three reasons. Iran's hard and soft power is exaggerated by most accounts; it is too limited to allow the Iranians to dominate the Persian Gulf let alone the Middle East, ...... powers and the West to balance Iran and contain its influence, even if it acquires nuclear weapons. If these limitations on Iranian power are taken into account the rise seems destined to be a short one......., and its brand of Shi‘ism has very limited appeal outside of Iran. Second, growing internal political and economic instability will seriously limit Iran's bid for regional dominance. Third, the failure to stop the Iranian nuclear program has led analysts to underestimate the ability of the other regional...

  17. The Rise of Iran

    DEFF Research Database (Denmark)

    Rahigh-Aghsan, Ali

    Iran is viewed as a rising power that poses an increasing threat to regional and even global security. This view is wrong for three reasons. Iran's hard and soft power is exaggerated by most accounts; it is too limited to allow the Iranians to dominate the Persian Gulf let alone the Middle East, ...... powers and the West to balance Iran and contain its influence, even if it acquires nuclear weapons. If these limitations on Iranian power are taken into account the rise seems destined to be a short one......., and its brand of Shi‘ism  has very limited appeal outside of Iran. Second, growing internal political and economic instability will seriously limit Iran's bid for regional dominance. Third, the failure to stop the Iranian nuclear program has led analysts to underestimate the ability of the other regional...

  18. A Survey of State and Local PV Program Response to Financial Innovation and Disparate Federal Tax Treatment in the Residential PV Sector

    Energy Technology Data Exchange (ETDEWEB)

    Bolinger, Mark [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Holt, Edward [Ed Holt & Associates, Inc., Harpswell, ME (United States)

    2015-06-01

    High up-front costs and a lack of financing options have historically been the primary barriers to the adoption of photovoltaics (PV) in the residential sector. State clean energy funds, which emerged in a number of states from the restructuring of the electricity industry in the mid-to-late 1990s, have for many years attempted to overcome these barriers through PV rebate and, in some cases, loan programs. While these programs (rebate programs in particular) have been popular, the residential PV market in the United States only started to achieve significant scale in the last five years – driven in large part by an initial wave of financial innovation that led to the rise of third-party ownership.

  19. 某高层住宅消防电梯间前室的防烟设计%Design of Smoke Control in the Room before Anti-fire Elevator Room of One High-rise Residential

    Institute of Scientific and Technical Information of China (English)

    闻利华

    2011-01-01

    This article focuses on introducing the design steps of smoke control system in the room before elevator room, including ways to determine the smoke control, calculating the air rate of pressurized air supply system and air supply outlet and verifying residual pressure fan.%本文重点介绍消防电梯问前室防烟系统的设计步骤,包括防烟方式的判断,加压送风系统的风量及送风口尺寸的计算以及风机余压的验证.

  20. ENERGY STAR Certified Residential Dishwashers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 6.0 ENERGY STAR Program Requirements for Residential Dishwashers that are effective as of...

  1. Utilization of waste heat of high-rise buildings. Definition of parameters for European countries. Abwaermenutzung von Hochbauten. Entwicklung von Kennziffern fuer europaeische Laender

    Energy Technology Data Exchange (ETDEWEB)

    Rudolph, R.; Gahrmann, A.; Haag, R.

    1980-01-01

    The object of the study is the quantity of waste heat of air conditioning installations, service water systems, heating systems in residential buildings, hospitals, schools, hotels, office buildings, department stores and swimming pools (as of end of 1978). Energetic calculations have been differentiated according to the following four climatic zones: I. Denmark, Northern Germany, II. Eastern France, Southern Germany, III. Great Britain, the Benelux countries, Northern France, Northern Italy, IV. Southern France, Central Italy. The countries of the European Community are assigned to three groups for the purpose of economy calculations. The economically useful savings potential per household amounts to 0-6 MWh/a in one- and two-family houses and to 0-10 MWh/a in multiple family dwellings. Heat recovery from exhaust air is economical for forced air-conditioned buildings. In the direct exhaust-air-to-fresh-air heat exchanging process, energy saving amounts to about 45-75% of requirements for meeting heat losses due to air exchange. Heat recovery from waste water of hotels and hospitals is economical, energy saving amounting to about 5 MWh/bed x a. Thus it is feasible to save a total of about 15% of primary energy requirements of the buildings examined in the EC. It is possible to save up to 2% economically, but only about 15% of the economically useful potential have been used.

  2. Residential energy usage comparison: Findings

    Energy Technology Data Exchange (ETDEWEB)

    Smith, B.A.; Uhlaner, R.T.; Cason, T.N.; Courteau, S. (Quantum Consulting, Inc., Berkeley, CA (United States))

    1991-08-01

    This report presents the research methods and results from the Residential Energy Usage Comparison (REUC) project, a joint effort by Southern California Edison Company (SCE) and the Electric Power Research Institute (EPRI). The REUC project design activities began in early 1986. The REUC project is an innovative demand-site project designed to measure and compare typical energy consumption patterns of energy efficient residential electric and gas appliances. 95 figs., 33 tabs.

  3. Investigation of structural changes in residential electricity demand

    Energy Technology Data Exchange (ETDEWEB)

    Chern, W.S.; Bouis, H.E.

    1982-09-23

    The purpose of this study was to investigate the stability of aggregate national residential electricity demand coefficients over time. The hypothesis is maintained that the aggregate residential demand is the sum of various end-use demand components. Since the end-use composition changes over time, the demand relationship may change as well. Since the end-use composition differs among regions, the results obtained from this study can be used for making inferences about regional differences in electricity demand relationships. There are two additional sources for a possible structural change. One is that consumers may react differently to declining and rising prices, secondly, the impact of the 1973 oil embargo may have shifted demand preferences. The electricity demand model used for this study is presented. A moving regression method was employed to investigate changes in residential electricity demand over time. The statistical results show a strikingly consistent pattern of change for most of the structural variables. The most important finding of this study is that the estimated structure of residential electricity demand changes systematically over time as a result of changes in the characteristics (both durability and saturation level) of the stock of appliances. Furthermore, there is not strong evidence that the structural changes in demand occurred due to either the reversal of the declining trend of electricity prices or the impact of the 1973 oil embarge. (LCL)

  4. Procedures for Calculating Residential Dehumidification Loads

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jon [National Renewable Energy Lab. (NREL), Golden, CO (United States); Booten, Chuck [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-06-01

    Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity. The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.

  5. Dynamic management of integrated residential energy systems

    Science.gov (United States)

    Muratori, Matteo

    dissertation presents a bottom-up highly resolved model of a generic residential energy eco-system in the United States. The model is able to capture the entire energy footprint of an individual household, to include all appliances, space conditioning systems, in-home charging of plug-in electric vehicles, and any other energy needs, viewing residential and transportation energy needs as an integrated continuum. The residential energy eco-system model is based on a novel bottom-up approach that quantifies consumer energy use behavior. The incorporation of stochastic consumer behaviors allows capturing the electricity consumption of each residential specific end-use, providing an accurate estimation of the actual amount of available controllable resources, and for a better understanding of the potential of residential demand response programs. A dynamic energy management framework is then proposed to manage electricity consumption inside each residential energy eco-system. Objective of the dynamic energy management framework is to optimize the scheduling of all the controllable appliances and in-home charging of plug-in electric vehicles to minimize cost. Such an automated energy management framework is used to simulate residential demand response programs, and evaluate their impact on the electric power infrastructure. For instance, time-varying electricity pricing might lead to synchronization of the individual residential demands, creating pronounced rebound peaks in the aggregate demand that are higher and steeper than the original demand peaks that the time-varying electricity pricing structure intended to eliminate. The modeling tools developed in this study can serve as a virtual laboratory for investigating fundamental economic and policy-related questions regarding the interplay of individual consumers with energy use. The models developed allow for evaluating the impact of different energy policies, technology adoption, and electricity price structures on the total

  6. The Common Problems Analysis and Countermeasure Research in the High-rise Building Smoke Exhaust Design%高层建筑防排烟设计中常见问题分析及对策研究

    Institute of Scientific and Technical Information of China (English)

    吴国华

    2014-01-01

    The design problems of high-rise building techn-ology smoke control are becoming more and more common, and more and more important. This paper analyzes three common issues in the design of high-rise building smoke exhaust, and puts forward the countermeasures in view of the-se smoke control problems.%高层建筑物防排烟的设计问题越来越常见,越来越重要。本文分析了高层建筑防排烟设计中常见的三个方面的问题,并针对防排烟的这些问题提出解决对策。

  7. [On the evaluation of health factors in high-rise buildings. 2. Bioclimatological consequences resulting from comparative measurements of the air ionisation in a high-rise building located in a heavily contaminated suburban area and at certain altitudes (author's transl)].

    Science.gov (United States)

    Möse, J R; Fischer, G

    1981-01-01

    According to accepted scientific theories inhaled small ions deliver their charges in the pulmonary alveoli and this leads to local recharges. This process stimulates structures of the central nervous system and the activity of the endocrine is excited, resulting in an enhancement of the general well-being. These possibilities of interpretation regarding a biological ionic effect are supported, with reservations (e.g. effects produced by a change in climate), by positive medical effects during and after a stay in a well-ventilated mountain climate or also in a sea-climate. Owing to their lower mobility the large ions are inhaled as small ions to an increasing extent. The chemical and physical noxa are delivered and deposited in the respiratory tract. They "stick" the epithelia in the trachea and in the bronchi as well as the endothelia in the lung vesicles. The number of the ciliary movements is reduced. Similar effects are known to be caused also by nicotine abuse. This results in a decreased ability of expectoration and a lower intake of oxygen by the alveoli. These facts could furnish an explanation for the increased vulnerability of city dwellers to infections diseases and to catarrh. The changed ionisation of air in urbanised areas (mainly large ions in high concentrations) definitely represents only one of the many risk factors. In addition to the attempt to characterize bioclimatically local weather conditions by means of the non-conventional parameter "air ionisation" our study has also been intended to establish biologically oriented criteria for the living in a high-rise building in a particularly unfavourable location. Under specific microclimatic conditions the uppermost storeys were at times bioclimatically favoured over the lowermost, especially when shallow air inversion is present. In such cases, small ions exclusively were registered in the upper storeys and large ions in the lower floors.

  8. PERSPECTIVE: The tripping points of sea level rise

    Science.gov (United States)

    Hecht, Alan D.

    2009-12-01

    When President Nixon created the US Environmental Protection Agency (EPA) in 1970 he said the environment must be perceived as a single, interrelated system. We are nowhere close to achieving this vision. Jim Titus and his colleagues [1] highlight one example of where one set of regulations or permits may be in conflict with another and where regulations were crafted in the absence of understanding the cumulative impact of global warming. The issue here is how to deal with the impacts of climate change on sea level and the latter's impact on wetland polices, clean water regulations, and ecosystem services. The Titus paper could also be called `The tripping points of sea level rise'. Titus and his colleagues have looked at the impact of such sea level rise on the east coast of the United States. Adaptive responses include costly large- scale investment in shore protection (e.g. dikes, sand replenishment) and/or ecosystem migration (retreat), where coastal ecosystems move inland. Shore protection is limited by available funds, while ecosystem migrations are limited by available land use. The driving factor is the high probability of sea level rise due to climate change. Estimating sea level rise is difficult because of local land and coastal dynamics including rising or falling land areas. It is estimated that sea level could rise between 8 inches and 2 feet by the end of this century [2]. The extensive data analysis done by Titus et al of current land use is important because, as they observe, `property owners and land use agencies have generally not decided how they will respond to sea level rise, nor have they prepared maps delineating where shore protection and retreat are likely'. This is the first of two `tripping points', namely the need for adaptive planning for a pending environmental challenge that will create economic and environment conflict among land owners, federal and state agencies, and businesses. One way to address this gap in adaptive management

  9. Modeling and off-design performance of a 1 kWe HT-PEMFC (high temperature-proton exchange membrane fuel cell)-based residential micro-CHP (combined-heat-and-power) system for Danish single-family households

    DEFF Research Database (Denmark)

    Arsalis, Alexandros; Nielsen, Mads Pagh; Kær, Søren Knudsen

    2011-01-01

    A novel proposal for the modeling and operation of a micro-CHP (combined-heat-and-power) residential system based on HT-PEMFC (High Temperature-Proton Exchange Membrane Fuel Cell) technology is described and analyzed to investigate its commercialization prospects. An HT-PEMFC operates at elevated...

  10. 76 FR 64924 - Updating State Residential Building Energy Efficiency Codes

    Science.gov (United States)

    2011-10-19

    ...The Department of Energy (DOE or Department) has preliminarily determined that the 2012 edition of the International Code Council (ICC) International Energy Conservation Code (IECC) (2012 IECC or 2012 edition) would achieve greater energy efficiency in low-rise residential buildings than the 2009 IECC. Upon publication of an affirmative final determination, States would be required to file certification statements to DOE that they have reviewed the provisions of their residential building code regarding energy efficiency and made a determination as to whether to update their code to meet or exceed the 2012 IECC. Additionally, this Notice provides guidance to States on how the codes have changed from previous versions, and the certification process should this preliminary determination be finalized.

  11. Waste removal systems and recycling participation in residential environments

    DEFF Research Database (Denmark)

    Thøgersen, John

    2002-01-01

    form of recycling (Ackerman, 1997; Pieters, 1989). Therefore, residential environments in developed countries increasingly contain separate collection systems for that fraction of waste that can be recycled, and hence re-utilized, in the production of new goods. These collection systemsare in addition......Systems for the removal of waste are important although often overlooked elements of any residential environment. It is an old insight that when these systems are ineffective (and this is globally and historically the rule rather than the exception), human living conditions and often even human...... health are severely impaired (Pieters, 1989). More recently, resource waste and environmental hazards from waste have given rise to public and political concern as well, even when disposal systems are well managed. This concern has led to efforts to divert solid waste away from disposal and towards some...

  12. The rise of Chrome

    Directory of Open Access Journals (Sweden)

    Jonathan Tamary

    2015-10-01

    Full Text Available Since Chrome’s initial release in 2008 it has grown in market share, and now controls roughly half of the desktop browsers market. In contrast with Internet Explorer, the previous dominant browser, this was not achieved by marketing practices such as bundling the browser with a pre-loaded operating system. This raises the question of how Chrome achieved this remarkable feat, while other browsers such as Firefox and Opera were left behind. We show that both the performance of Chrome and its conformance with relevant standards are typically better than those of the two main contending browsers, Internet Explorer and Firefox. In addition, based on a survey of the importance of 25 major features, Chrome product managers seem to have made somewhat better decisions in selecting where to put effort. Thus the rise of Chrome is consistent with technical superiority over the competition.

  13. Is sea-level rising?

    Digital Repository Service at National Institute of Oceanography (India)

    Unnikrishnan, A.S.

    There has been considerable research on sea-level-rise caused by global warming. The various reports of the Intergovernmental Panel on Climate Change (IPCC) made assessments of observed sea level rise and future projections. Figure 1 shows a global...

  14. Financing Non-Residential Photovoltaic Projects: Options and Implications

    Energy Technology Data Exchange (ETDEWEB)

    Bolinger, Mark

    2009-01-09

    .ii Specifically, due to financial innovation, non-residential entities interested in PV no longer face prohibitively high up-front costs, no longer need to be able to absorb Tax Benefits in order to make the economics pencil out, no longer need to be able to operate and maintain the system, and no longer need to accept the risk that the system does not perform as expected.

  15. Effects of Floor Level and Building Type on Residential Levels of Outdoor and Indoor Polycyclic Aromatic Hydrocarbons, Black Carbon, and Particulate Matter in New York City

    Directory of Open Access Journals (Sweden)

    Rachel L. Miller

    2011-05-01

    Full Text Available Consideration of the relationship between residential floor level and concentration of traffic-related airborne pollutants may predict individual residential exposure among inner city dwellers more accurately. Our objective was to characterize the vertical gradient of residential levels of polycyclic aromatic hydrocarbons (PAH; dichotomized into Σ8PAHsemivolatile (MW 178–206, and Σ8PAHnonvolatile (MW 228–278, black carbon (BC, PM2.5 (particulate matter by floor level (FL, season and building type. We hypothesize that PAH, BC and PM2.5 concentrations may decrease with higher FL and the vertical gradients of these compounds would be affected by heating season and building type. PAH, BC and PM2.5 were measured over a two-week period outdoor and indoor of the residences of a cohort of 5–6 year old children (n = 339 living in New York City’s Northern Manhattan and the Bronx. Airborne-pollutant levels were analyzed by three categorized FL groups (0–2nd, 3rd–5th, and 6th–32nd FL and two building types (low-rise versus high-rise apartment building. Indoor Σ8PAHnonvolatile and BC levels declined with increasing FL. During the nonheating season, the median outdoor Σ8PAHnonvolatile, but not Σ8PAHsemivolatile, level at 6th–2nd FL was 1.5–2 times lower than levels measured at lower FL. Similarly, outdoor and indoor BC concentrations at 6th–32nd FL were significantly lower than those at lower FL only during the nonheating season (p < 0.05. In addition, living in a low-rise building was associated significantly with higher levels of Σ8PAHnonvolatile and BC. These results suggest that young inner city children may be exposed to varying levels of air pollutants depending on their FL, season, and building type.

  16. An evaluation of options to mitigate voltage rise due to increasing PV penetration in distribution networks

    Directory of Open Access Journals (Sweden)

    Carter Craig E.

    2017-01-01

    Full Text Available Australia and most other countries are adopting renewable energy generation as the dominant means of reducing dependence on fossil fuels. This has been made more feasible by the exponential take-up of solar photovoltaic (PV systems and their concurrent production scale-up and cost decline. Rooftop solar PV, combined with battery storage, seems likely to be the dominant means of providing household electricity needs. In response to the technical challenges from rooftop PV, network utilities have implemented various low cost options to cope with PV’s impact on network voltages. However, if we want this clean energy technology to fully utilise the available roof space and eventually meet residential electricity needs, additional hardware, control and commercial options will need to be adopted by both network utilities and their customers to overcome the technical barriers, especially voltage rise. This paper presents the authors’ evaluations of options to mitigate voltage rise, including operating solar inverters with reactive power absorption (var absorbing, dependent only on solar power output or operating the solar inverters in a volt–var response mode (voltage droop control where the inverter adjusts its reactive power (Q in response to changes in its terminal voltage – Q(V. This paper also considers the fulltime Q(V option, where an inverter’s reactive power capacity is independent of solar conditions – statcom mode. The network utility option of using line drop compensation (LDC – used on long rural MV feeders on urban MV feeders during daylight hours is assessed to lessen voltage rise on LV feeders with low net loading or reverse power flow due to high solar PV generation. The paper concludes that a combination of solar inverters performing fast fulltime voltage droop control outside a voltage deadband (statcom mode and HV/MV substation transformers with slow acting daytime LDC mitigates voltage rise, whilst limiting feeder

  17. 24 CFR 203.672 - Residential areas.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Residential areas. 203.672 Section... FAMILY MORTGAGE INSURANCE Servicing Responsibilities Occupied Conveyance § 203.672 Residential areas. (a) For the purposes of occupied conveyance considerations, a residential area is any area which...

  18. Residential radon in Finland: sources, variation, modelling and dose comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Arvela, H.

    1995-09-01

    The study deals with sources of indoor radon in Finland, seasonal variations in radon concentration, the effect of house construction and ventilation and also with the radiation dose from indoor radon and terrestrial gamma radiation. The results are based on radon measurements in approximately 4000 dwellings and on air exchange measurements in 250 dwellings as well as on model calculations. The results confirm that convective soil air flow is by far the most important source of indoor radon in Finnish low-rise residential housing. (97 refs., 61 figs., 30 tabs.).

  19. The waiting children : Pathways (and future) of children in long-term residential care

    NARCIS (Netherlands)

    López, Mónica; del Valle, Jorge F.

    2015-01-01

    There is an international consensus about the need to avoid prolonged stays in residential care and a preference for family-based interventions for those children who have been separated from their families. Nevertheless, Spanish statistics show a high number of children entering residential

  20. Belongingness--The Critical Variable in the Residential Treatment of Alcoholism.

    Science.gov (United States)

    Machell, David F.

    Many alcohol treatment programs have stressed a sense of belongingness as a means for successful treatment of alcoholics in a residential setting. An examination of the effectiveness of this strategy in highly structured and less structured programs involved 200 chronic, recidivistic male adult alcoholics in a residential program. Subjects were…

  1. Predictors of Success in a Residential Education Placement for Foster Youths

    Science.gov (United States)

    Jones, Loring P.

    2012-01-01

    This study examines factors that contributed to successful outcomes (graduated high school, remained in school, went to a lower level of care, or reunified with parents) for the first 246 residents of a residential education placement. Residential education placements' primary purpose is to provide an educational program rather than mental health…

  2. Residential segregation and the survival of U.S. urban public hospitals.

    Science.gov (United States)

    Ko, Michelle; Needleman, Jack; Derose, Kathryn Pitkin; Laugesen, Miriam J; Ponce, Ninez A

    2014-06-01

    Residential segregation is associated geographic disparities in access to care, but its impact on local health care policy, including public hospitals, is unknown. We examined the effects of racial residential segregation on U.S. urban public hospital closures from 1987 to 2007, controlling for hospital, market, and policy characteristics. We found that a high level of residential segregation moderated the protective effects of Black population composition, such that a high level of residential segregation, in combination with a high percentage of poor residents, conferred a higher likelihood of hospital closure. More segregated and poorer communities face disadvantages in access to care that may be compounded as a result of instability in the health care safety net. Policy makers should consider the influence of social factors such as residential segregation on the allocation of the safety net resources.

  3. Trends of Sustainable Residential Architecture

    OpenAIRE

    Narvydas, A

    2015-01-01

    The article is based on Master’s research conducted during Scottish Housing Expo 2010. The aim of the research was to determine the prevailing trends in sustainable residential architecture. Each trend can be described by features detected during visual and technical observation of project data. Based on that architects may predict possible problems related to a specific trend.

  4. ENERGY STAR Certified Residential Freezers

    Science.gov (United States)

    Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Residential Refrigerators and Freezers that are effective as of September 15, 2014. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=refrig.pr_crit_refrigerators

  5. Main challenges of residential areas

    Directory of Open Access Journals (Sweden)

    Oana Luca

    2017-06-01

    Full Text Available The present article is a position paper aiming to initiate a professional debate related to the aspects related to the urban dysfunctions leading to the wear of the residential areas. The paper proposes a definition of the wear process, identify the main causes leading to its occurrence and propose a number of solutions to neutralise the dysfunctions. The three wearing phases of residential areas components are emphasized, exploring their lifecycle. In order to perform the study of urban wear, the status of the residential areas components can be established and monitored, and also the variables of the function that can mathematically model the specific wear process may be considered. The paper is considered a first step for the model adjustment, to be tested and validated in the following steps. Based on the mathematical method and model, there can be created, in a potential future research, the possibility of determining the precarity degree for residential areas/neighbourhoods and cities, by minimising the subjective component of the analyses preceding the decision for renovation or regeneration.

  6. Technical Problems of Residential Construction

    Science.gov (United States)

    Nowogońska, Beata; Cibis, Jerzy

    2017-10-01

    Beauty, utility, durability - these are the features of good architecture and should also be the distinguishing qualities of every residential building. But do beauty and utility remain along with the passing of time? Performance characteristics are an indicator of both, the technical as well as aesthetic state of buildings. Aesthetic needs are in disagreement with the merciless aging process. The beauty of a city is formed not only by the original forms of new residential buildings, but also by existing tenement housing; thus preserving their aesthetics becomes a necessity. Time is continuously passing and along with it, aging intensifies. The aging process is a natural phenomenon for every material. The life expectancy of building materials is also limited. Along with the passing of time, the technical state of residential buildings continuously deteriorates. With the passing of time, the aesthetic values and preferences of users of flats change and the usability of the building decreases. The permanence of buildings, including residential buildings, is shaped not only by the forces of nature but also by activities of humans. A long lifespan is ensured by carrying out ongoing, systematic renovation-repair works. It is thanks to them that buildings derived from past centuries are still being used, and their market attractiveness is not decreasing.

  7. The Risk of Metachronous Advanced Colorectal Neoplasia Rises in Parallel with an Increasing Number of High-Risk Findings at Baseline.

    Science.gov (United States)

    Lee, Seung Min; Kim, Jeong Hwan; Sung, In Kyung; Hong, Sung Noh

    2015-11-23

    Colorectal adenomas that are ≥10 mm have villous histology or high-grade dysplasia, or that are associated with ≥3 adenomas are considered high-risk for metachronous advanced neoplasia. We evaluated the cumulative incidence of metachronous advanced neoplasia according to the total number of high-risk findings detected on baseline colonoscopy. This was a retrospective cohort study performed in 862 patients who underwent removal of colorectal adenomas between 2005 and 2009. At least one surveillance colonoscopy had been conducted at Konkuk University Medical Center, Seoul, Korea. The cumulative incidence of metachronous advanced neoplasia in patients with 0, 1, 2, and 3-4 high-risk findings at 1 year were 0.7%, 1.3%, 2.8%, and 8.0%; at 3 years, those were 5.9%, 11.9%, 15.5%, and 24.7%; and at 5 years, those were 8.5%, 18.7%, 26.3%, and 37.2%, respectively. In a multivariate model, the risk of metachronous advanced neoplasia was significantly higher for the multiple high-risk findings group when compared with the 0 high-risk findings group (1 high-risk (+) hazard ratio, 1.86 [95% confidence interval, 1.00-3.44]; 2 high-risk (+) 1.84 [0.88-3.84]; and 3-4 high-risk (+) 3.29 [1.54-7.01]; ptrend=0.020). The presence of overlapping multiple high-risk findings was associated with an increased risk of advanced neoplasia during surveillance.

  8. Residential radon and lung cancer incidence in a Danish cohort

    DEFF Research Database (Denmark)

    Bräuner, Elvira Vaclavik; Andersen, Claus Erik; Sørensen, Mette

    2012-01-01

    High-level occupational radon exposure is an established risk factor for lung cancer. We assessed the long-term association between residential radon and lung cancer risk using a prospective Danish cohort using 57,053 persons recruited during 1993–1997. We followed each cohort member for cancer...... occurrence until 27 June 2006, identifying 589 lung cancer cases. We traced residential addresses from 1 January 1971 until 27 June 2006 and calculated radon at each of these addresses using information from central databases regarding geology and house construction. Cox proportional hazards models were used...... to estimate incidence rate ratios (IRR) and 95% confidence intervals (CI) for lung cancer risk associated with residential radon exposure with and without adjustment for sex, smoking variables, education, socio-economic status, occupation, body mass index, air pollution and consumption of fruit and alcohol...

  9. Improve isolation materials and recommendation of residential buildings in Kazakhstan

    Science.gov (United States)

    Kim, Yuliya; Sun, Cheng; Nuguzhinov, Zhmagul

    2017-04-01

    The article shows the problem of high volumes of energy use in Kazakhstan and introduction of energy-efficient technologies, production and causes of the problem. To improve the thermal comfort, needed primarily to improve the thermal insulation properties of materials. This article examines the characteristics of thermal insulation materials and their application in the construction process in Kazakhstan. The material properties are calculated and shown as formulas, which can use in the future in the design of residential buildings. The construction studied of passive technology in the residential area. By the design process and the combination of design variables selected option.

  10. Evaluation of advanced technologies for residential appliances and residential and commercial lighting

    Energy Technology Data Exchange (ETDEWEB)

    Turiel, I.; Atkinson, B.; Boghosian, S.; Chan, P.; Jennings, J.; Lutz, J.; McMahon, J.; Rosenquist, G.

    1995-01-01

    Section 127 of the Energy Policy Act requires that the Department of Energy (DOE) prepare a report to Congress on the potential for the development and commercialization of appliances that substantially exceed the present federal or state efficiency standards. Candidate high-efficiency appliances must meet several criteria including: the potential exists for substantial improvement (beyond the minimum established in law) of the appliance`s energy efficiency; electric, water, or gas utilities are prepared to support and promote the commercialization of such appliances; manufacturers are unlikely to undertake development and commercialization of such appliances on their own, or development and production would be substantially accelerated by support to manufacturers. This report describes options to improve the efficiency of residential appliances, including water heaters, clothes washers and dryers, refrigerator/freezers, dishwashers, space heating and cooling devices, as well as residential and commercial lighting products. Data from this report (particularly Appendix 1)were used to prepare the report to Congress mentioned previously. For the residential sector, national energy savings are calculated using the LBL Residential Energy Model. This model projects the number of households and appliance saturations over time. First, end-use consumption is calculated for a base case where models that only meet the standard replace existing models as these reach the end of their lifetime. Second, models with efficiencies equal to the technology under consideration replace existing models that reach the end of their lifetime. For the commercial sector, the COMMEND model was utilized to project national energy savings from new technologies. In this report, energy savings are shown for the period 1988 to 2015.

  11. Nanotechnology opportunities in residential and non-residential construction

    Science.gov (United States)

    Theodore H. Wegner; Jerrold E. Winandy; Michael A. Ritter

    2005-01-01

    Over 1.9 × 106 housing units are constructed in the United States in 2004. On a volume basis, wood products comprise almost 80% of all materials used in residential housing. It is estimated that over 7 × 109 m3 of lumber have gone into structures in the United States over the last century. Half of the wood products now used in construction are engineered wood...

  12. Residential carbon monoxide poisoning from motor vehicles.

    Science.gov (United States)

    Hampson, Neil B

    2011-01-01

    Although morbidity and mortality from accidental carbon monoxide (CO) poisoning are high in the United States, identification of common but poorly recognized sources should help prevention efforts. The study aimed to describe CO poisoning of home occupants due to a vehicle left running in an attached garage. News stories reporting incidents of US CO poisoning were collected daily from March 2007 to September 2009 via a news.Google.com search and data extracted. Patients were individuals reported in the media to have been poisoned with CO in their home by a vehicle running in the attached garage. Main outcome measures were frequency of occurrence, geographic distribution, patient demographics, and mortality. Of 837 CO poisoning incidents reported in US news media over 2 and a half years, 59 (8%) were the result of a vehicle left running in the garage. The elderly were disproportionately affected, with incidents most common in states with larger elderly populations and 29% of cases with age specified occurring in individuals older than 80 years. Among those older than 80 years, 15 of 17 were found dead at the scene. Residential CO poisoning from a vehicle running in the garage is common, disproportionately affects the elderly, has a high mortality rate, and should be preventable with a residential CO alarm. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. 试论城市高层建筑消防排烟系统的检查与维护%The Inspection and Maintenance of City High-rise Building Fire Smoke Extraction System

    Institute of Scientific and Technical Information of China (English)

    刘彦富

    2014-01-01

    Due to the high building have high floors, big safe hidden troubles, requirements for the smoke control system are natural y more strictly. This paper wil explain the importance of smoke control system in high-rise building, and analyze so-me problems, check and maintenance method of the smoke co-ntrol system at present.%高层建筑由于楼层高,安全隐患大,对于防排烟系统的要求自然比较严格。本文将在阐释高层建筑防排烟系统重要性的基础上,重点分析防排烟系统目前存在的一些问题及检查与维护的方法。

  14. From Civic Conservation to the Age of Ecology: The Rise and Synthesis of Ecological Ideas in the American High School Science Curriculum, 1900-1980

    Science.gov (United States)

    Laubach, Stephen A.

    2013-01-01

    Ecological ideas have been manifested in diverse ways in American high schools since the early twentieth century. Core scientific concepts in ecology--the study of the relationship between organisms and their environment--include adaptations, plant succession, ecosystem ecology, and population ecology. This dissertation argues, however, that there…

  15. Perceived public health effects of occupational and residential ...

    African Journals Online (AJOL)

    High levels of environmental contamination can occur from e-waste processing, putting workers and residents in surrounding areas at risk as they are likely to be exposed to complex mixtures of unknown toxicity. This study was aimed at assessing the perceived public health effects of occupational and residential exposures ...

  16. Determinants of Residential Property Value in Nigeria – A Neural ...

    African Journals Online (AJOL)

    This study investigated, by means of artificial intelligent system, the influence of residential real estate property characteristics on property values (prices) in Nigeria, using two major cities (Benin and Lagos) as examples. It revealed a high positive linear correlation between property characteristics and the property market ...

  17. Risk Profiles of Children Entering Residential Care: A Cluster Analysis

    Science.gov (United States)

    Hagaman, Jessica L.; Trout, Alexandra L.; Chmelka, M. Beth; Thompson, Ronald W.; Reid, Robert

    2010-01-01

    Children in residential care are a heterogeneous population, presenting various combinations of risks. Existing studies on these children suggest high variability across multiple domains (e.g., academics, behavior). Given this heterogeneity, it is important to begin to identify the combinations and patterns of multiple risks, or risk profiles,…

  18. Application of composite materials. Curtain wall for protection of TV electric wave reflection interference due to high-rise buildings; Konna tokoro ni fukugo zairyo. Koso biru ni yoru terebi denpa hansha shogai no boshiyo katen uoru

    Energy Technology Data Exchange (ETDEWEB)

    Kabayashi, M.; Kasashima, Y.; Nakagawa, H. [Kajima Construction Co. Ltd., Tokyo (Japan)] Otani, Y. [Kureha Chemical Industry Co. Ltd., Tokyo (Japan)

    1998-05-15

    In company with advancement of the high-rise buildings, the occurrence of the TV waves reflection interference increases. On a case of small scale buildings, it can be treated by installation of a common receiving facility and a cable television, but on a case of large scale super high-rise buildings, it is most effective and economical to convert an objective wall to one with lower reflection of TV waves. As an exterior wall used for its countermeasure, a ferrite type electric wave absorption wall was developed before 10 years and actualized which was buried ferrite tiles, one of electric wave absorbers into a pre-case concrete (PCa) curtain wall. And, recently, a resistor membrane type electric wave absorbing wall, and electric wave transmissive wall, and so for the with equal electric wave absorbing feature to the ferrite type electric wave absorbing wall, light weight and good workable execution were developed and actualized. These exterior walls for countermeasures are composed of a composite adding a new material to the conventional PCa curtain wall. As authors started this research and development earlier to utilize a lot of buildings, outlines of these researches and developments are introduced. 8 figs.

  19. The rise of ampicillin-resistant Enterococcus faecium high-risk clones as a frequent intestinal colonizer in oncohaematological neutropenic patients on levofloxacin prophylaxis: a risk for bacteraemia?

    Science.gov (United States)

    Sánchez-Díaz, A M; Cuartero, C; Rodríguez, J D; Lozano, S; Alonso, J M; Rodríguez-Domínguez, M; Tedim, A P; Del Campo, R; López, J; Cantón, R; Ruiz-Garbajosa, P

    2016-01-01

    Levofloxacin extended prophylaxis (LEP), recommended in oncohaematological neutropenic patients to reduce infections, might select resistant bacteria in the intestine acting as a source of endogenous infection. In a prospective observational study we evaluated intestinal emergence and persistence of ampicillin-resistant Enterococcus faecium (AREfm), a marker of hospital adapted high-risk clones. AREfm was recovered from the faeces of 52 patients with prolonged neutropenia after chemotherapy, at admission (Basal), during LEP, and twice weekly until discharge (Pos-LEP). Antibiotic susceptibility, virulence traits and population structure (pulsed-field gel electrophoresis and multilocus sequence typing) were determined and compared with bacteraemic isolates. Gut enterococcal population was monitored using a quantitative PCR quantification approach. AREfm colonized 61.4% of patients (194/482 faecal samples). Sequential AREfm acquisition (25% Basal, 36.5% LEP, 50% Pos-LEP) and high persistent colonization rates (76.9-89.5%) associated with a decrease in clonal diversity were demonstrated. Isolates were clustered into 24 PFGE-patterns within 13 sequence types, 95.8% of them belonging to hospital-associated Bayesian analysis of population structure subgroups 2.1a and 3.3a. Levofloxacin resistance and high-level streptomycin resistance were a common trait of these high-risk clones. AREfm-ST117, the most persistent clone, was dominant (60.0% isolates, 32.6% patients). It presented esp gene and caused 18.2% of all bacteraemia episodes in 21% of patients previously colonized by this clone. In AREfm-colonized patients, intestinal enrichment in the E. faecium population with a decline in total bacterial load was observed. AREfm intestinal colonization increases during hospital stay and coincides with enterococci population enrichment in the gut. Dominance and intestinal persistence of the ST117 clone might increase the risk of bacteraemia. Copyright © 2015 European Society of

  20. The Relationship Between Spatial Configuration and Social Interaction in High-Rise Flats: A Case Study On The Jatinegara Barat in Jakarta.

    Directory of Open Access Journals (Sweden)

    Ridwana Rifan

    2018-01-01

    The results of this study indicate that: (1 the relationship of spatial configuration to social interaction level in Jatinegara Barat flats can be positive or negative. (2 Positive relationships are found on the1st and 2ndfloor areas. High configuration values with high interaction levels are found in shared spaces on the 1st and 2nd floors with characteristics such as open space, large space, and availability of interaction supporting elements, while low configuration values with low interaction levels are found in more confined spaces such as private spaces and narrow corridors. (3 Negative relationships are found in the corridor and shared space in front of the elevator on each typical floors. Shared space in front of the elevator that has high spatial configuration value with large area show a low level of social interaction. While corridor with lower configuration value with the narrow area but have supporting elements such as chairs, mats, and shops have a higher level of social interaction. (4 This study shows that in the case of the relationship between spatial configuration and social interaction, availability of interaction supporting elements has greater influence rather than any other spatial factors.

  1. Design and optimization of zero-energy-consumption based solar energy residential building systems

    Science.gov (United States)

    Zheng, D. L.; Yu, L. J.; Tan, H. W.

    2017-11-01

    Energy consumption of residential buildings has grown fast in recent years, thus raising a challenge on zero energy residential building (ZERB) systems, which aim at substantially reducing energy consumption of residential buildings. Thus, how to facilitate ZERB has become a hot but difficult topic. In the paper, we put forward the overall design principle of ZERB based on analysis of the systems’ energy demand. In particular, the architecture for both schematic design and passive technology is optimized and both energy simulation analysis and energy balancing analysis are implemented, followed by committing the selection of high-efficiency appliance and renewable energy sources for ZERB residential building. In addition, Chinese classical residential building has been investigated in the proposed case, in which several critical aspects such as building optimization, passive design, PV panel and HVAC system integrated with solar water heater, Phase change materials, natural ventilation, etc., have been taken into consideration.

  2. Economic aspects of possible residential heating conservation

    Energy Technology Data Exchange (ETDEWEB)

    Hopkowicz, M.; Szul, A. [Technical Univ., Cracow (Poland)

    1995-12-31

    The paper presents methods of evaluation of energy and economy related effects of different actions aimed at conservation in residential buildings. It identifies also the method of selecting the most effective way of distribution funds assigned to weatherization as well as necessary improvements to be implemented within the heating node and the internal heating system of the building. The analysis of data gathered for four 11-stories high residential buildings of {open_quotes}Zeran{close_quotes} type being subject of the Conservation Demonstrative Project, included a differentiated scope of weatherization efforts and various actions aimed at system upgrading. Basing upon the discussion of the split of heat losses in a building as well as the established energy savings for numerous options of upgrading works, the main problem has been defined. It consists in optimal distribution of financial means for the discussed measures if the total amount of funds assigned for modifications is defined. The method based upon the principle of relative increments has been suggested. The economical and energy specifications of the building and its components, required for this method have also been elaborated. The application of this method allowed to define the suggested optimal scope of actions within the entire fund assigned for the comprehensive weatherization.

  3. The Rise of the Digital Public Library

    Science.gov (United States)

    McKendrick, Joseph

    2012-01-01

    There is a growing shift to digital offerings among public libraries. Libraries increasingly are fulfilling roles as technology hubs for their communities, with high demand for technology and career development training resources. Ebooks and other digital materials are on the rise, while print is being scaled back. More libraries are turning to…

  4. The rise of the photosynthetic rate when light intensity increases is delayed in ndh gene-defective tobacco at high but not at low CO2 concentrations

    Directory of Open Access Journals (Sweden)

    Mercedes eMartin

    2015-02-01

    Full Text Available The 11 plastid ndh genes have hovered frequently on the edge of dispensability, being absent in the plastid DNA of many algae and certain higher plants. We have compared the photosynthetic activity of tobacco (Nicotiana tabacum, cv. Petit Havana with five transgenic lines (ndhF, pr-ndhF, T181D, T181A and ndhF FC and found that photosynthetic performance is impaired in transgenic ndhF-defective tobacco plants at rapidly fluctuating light intensities and higher than ambient CO2 concentrations. In contrast to wild type and ndhF FC, which reach the maximum photosynthetic rate in less than one min when light intensity suddenly increases, ndh defective plants (ndhF and T181A show up to a 5 min delay in reaching the maximum photosynthetic rate at CO2 concentrations higher than the ambient 360 ppm. Net photosynthesis was determined at different CO2 concentrations when sequences of 130, 870, 61, 870 and 130 μmol m−2 s−1 PAR sudden light changes were applied to leaves and photosynthetic efficiency and entropy production were determined as indicators of photosynthesis performance. The two ndh-defective plants, ndhF and T181A, had lower photosynthetic efficiency and higher entropy production than wt, ndhF FC and T181D tobacco plants, containing full functional ndh genes, at CO2 concentrations above 400 ppm. We propose that the Ndh complex improves cyclic electron transport by adjusting the redox level of transporters during the low light intensity stage. In ndhF-defective strains, the supply of electrons through the Ndh complex fails, transporters remain over-oxidized (specially at high CO2 concentrations and the rate of cyclic electron transport is low, impairing the ATP level required to rapidly reach high CO2 fixation rates in the following high light phase. Hence, ndh genes could be dispensable at low but not at high atmospheric concentrations of CO2.

  5. The rise of the photosynthetic rate when light intensity increases is delayed in ndh gene-defective tobacco at high but not at low CO2 concentrations.

    Science.gov (United States)

    Martín, Mercedes; Noarbe, Dolores M; Serrot, Patricia H; Sabater, Bartolomé

    2015-01-01

    The 11 plastid ndh genes have hovered frequently on the edge of dispensability, being absent in the plastid DNA of many algae and certain higher plants. We have compared the photosynthetic activity of tobacco (Nicotiana tabacum, cv. Petit Havana) with five transgenic lines (ΔndhF, pr-ΔndhF, T181D, T181A, and ndhF FC) and found that photosynthetic performance is impaired in transgenic ndhF-defective tobacco plants at rapidly fluctuating light intensities and higher than ambient CO2 concentrations. In contrast to wild type and ndhF FC, which reach the maximum photosynthetic rate in less than 1 min when light intensity suddenly increases, ndh defective plants (ΔndhF and T181A) show up to a 5 min delay in reaching the maximum photosynthetic rate at CO2 concentrations higher than the ambient 360 ppm. Net photosynthesis was determined at different CO2 concentrations when sequences of 130, 870, 61, 870, and 130 μmol m(-2) s(-1) PAR sudden light changes were applied to leaves and photosynthetic efficiency and entropy production (Sg) were determined as indicators of photosynthesis performance. The two ndh-defective plants, ΔndhF and T181A, had lower photosynthetic efficiency and higher Sg than wt, ndhF FC and T181D tobacco plants, containing full functional ndh genes, at CO2 concentrations above 400 ppm. We propose that the Ndh complex improves cyclic electron transport by adjusting the redox level of transporters during the low light intensity stage. In ndhF-defective strains, the supply of electrons through the Ndh complex fails, transporters remain over-oxidized (specially at high CO2 concentrations) and the rate of cyclic electron transport is low, impairing the ATP level required to rapidly reach high CO2 fixation rates in the following high light phase. Hence, ndh genes could be dispensable at low but not at high atmospheric concentrations of CO2.

  6. Dielectric-wall linear accelerator with a high voltage fast rise time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators

    Science.gov (United States)

    Caporaso, George J.; Sampayan, Stephen E.; Kirbie, Hugh C.

    1998-01-01

    A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface.

  7. The rise of micropharma.

    Science.gov (United States)

    Barden, Christopher J; Weaver, Donald F

    2010-02-01

    The drug discovery pipelines of the major pharmaceutical companies have become shockingly depleted, foreshadowing a potential crisis in the ability of Big Pharma to meet the pharmaceutical demands created by the ever-changing spectrum of human disease. However, from this major crisis is emerging a major opportunity, namely micropharma--academia-originated biotech start-up companies that are efficient, innovative, product-focused and small. In this Feature, we discuss a 'new ecosystem' for drug development, with high-risk innovation in micropharma leading to Big Pharma clinical trials; we also identify the 'five golden goals' that micropharma must strive to achieve to attain success. Although micropharma will encounter numerous hurdles on this road to success, there is room for optimism that micropharma might have the capacity to address society's growing, but unmet, need for effective therapeutics over coming years. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  8. Relatively low HIV infection rates in rural Uganda, but with high potential for a rise: a cohort study in Kayunga District, Uganda.

    Directory of Open Access Journals (Sweden)

    David Guwatudde

    Full Text Available BACKGROUND: Few studies have been conducted in Uganda to identify and quantify the determinants of HIV-1 infection. We report results from a community-based cohort study, whose primary objectives were to determine HIV-1 prevalence, incidence, and determinants of these infections, among other objectives. METHODOLOGY: Consenting volunteers from the rural district of Kayunga in Uganda aged 15-49 years were enrolled between March and July 2006. Participants were evaluated every six months. A questionnaire that collected information on behavioral and other HIV-1 risk factors was administered, and a blood sample obtained for laboratory analysis at each study visit. PRINCIPAL FINDINGS: HIV-1 prevalence among the 2025 participants was 9.9% (95% CI = 8.6%-11.2%. By the end of 12 months of follow-up, 1689.7 person-years had been accumulated, with a median follow-up time of 11.97 months. Thirteen HIV-1 incident cases were detected giving an annual HIV-1 incidence of 0.77% (95% CI = 0.35-1.19. Prevalence of HSV-2 infection was 57% and was strongly associated with prevalent HIV-1 infection (adjusted Odds Ratio = 3.9, 95% CI = 2.50-6.17; as well as incident HIV-1 infection (adjusted Rate Ratio (RR = 8.7, 95% CI = 1.11-67.2. The single most important behavioral characteristic associated with incident HIV infection was the number of times in the past 6 months, a participant had sex with person(s they suspected/knew were having sex with others; attaining statistical significance at 10 times and higher (adjusted RR = 6.3, 95% CI = 1.73-23.1. By the end of 12 months of follow-up, 259 participants (13% were lost to follow-up, 13 (0.6% had died, and 2 (0.1% had withdrawn consent. CONCLUSIONS: Despite relatively low HIV-1 incidence observed in this community, prevalence remains relatively high. In the presence of high prevalence of HSV-2 infection and the behavioral characteristic of having sex with more than one partner, there is potential for increase in HIV-1

  9. Preparing for Extreme Heat in India: Using High-Resolution Climate Models to Explore the Impact of Rising Temperatures on Human Health and Labor Productivity

    Science.gov (United States)

    Shaw, C.

    2016-12-01

    Globally, higher daily peak temperatures and longer, more intense heat waves are becoming increasingly frequent due to climate change. India, with relatively low GDP per capita, high population density, and tropical climate, is particularly vulnerable to these trends. In May 2015, one of the worst heat waves in world history hit the country, culminating in at least 2,300 officially-reported deaths as temperatures in some regions reached 48°C. As a result of climate change, heat waves in this region will last longer, be more extreme, and occur with greater frequency in the coming years. Impacts will be felt most acutely by vulnerable populations, which include not only those with frail health, but also populations otherwise considered healthy whose livelihood involves working under exposure to high temperatures. The problem is exacerbated by low levels of economic development, particularly in the under-provision of medical services, a higher proportion of weather-reliant income sources, and the inability to recover quickly from shocks. Responding to these challenges requires collaboration among the disciplines of climate science, public health, economics, and public policy. This project, presented as an online web application using Esri's ArcGIS Story Map, covers 1) the impact of extreme heat on human mortality, 2) the impact of combined heat and humidity (as measured by wet bulb globe temperature) on labor productivity, and 3) emerging best practices in adaptation planning by local municipalities and NGOs. The work is presented in a format that is designed to allow policymakers to take a deeper dive into the literature linking extreme temperature to human health and labor productivity, combined with interactive mapping tools that allow planners to drill down to data at the district level across the country of India. Further, the work presents a case study of heat adaptation planning efforts that have already been implemented in the city of Ahmedabad, allowing

  10. Lateral Displacement And Shear Lag Effect Of High-Rise Buildings With Diagrid SystemThat Is Constructed Above A Frame

    Directory of Open Access Journals (Sweden)

    Abd. Samat Roslida

    2017-01-01

    Full Text Available Diagrid system has gained a wide acceptance in the design of tall buildings due to its many advantages including its high structural efficiency in resisting both gravity and lateral loads. Most diagrid structures that had been studied have full triangulated members from the ground level to the top of the buildings where comparison in the effectiveness in minimizing the lateral displacement was often made between structures with full diagrid, frame and outrigger system. Nevertheless, no study has been performed on the effectiveness of the diagrid that is constructed above a frame system. The objective of this research is to understand the behavior of the lateral displacement and shear lag effect due to wind load when the diagrid structure is constructed above a frame. Models of sixty storey buildings were analyzed by using Staad.Pro software. The level where the diagrid members started and the spacing of vertical base columns of the frame were altered. The lateral displacement and shear lag effect resembled closely of those of the model of full diagrid when the diagrid was started at level 3, and the vertical base columns were uniformly spaced at 6 metres.

  11. The relation between residential property and its surroundings and day- and night-time residential burglary

    NARCIS (Netherlands)

    Montoya, Lorena; Junger, Marianne; Ongena, Yfke

    This article examines how residential property and its surroundings influence day- and night-time residential burglary. Crime Prevention Through Environmental Design (CPTED) principles of territoriality, surveillance, access control, target hardening, image maintenance, and activity support underpin

  12. ER-alpha-cDNA as part of a bicistronic transcript gives rise to high frequency, long term, receptor expressing cell clones.

    Directory of Open Access Journals (Sweden)

    Michal Shenfeld

    Full Text Available Within the large group of Estrogen Receptor alpha (ERα-negative breast cancer patients, there is a subgroup carrying the phenotype ERα(-, PR(-, and Her2(-, named accordingly "Triple-Negative" (TN. Using cell lines derived from this TN group, we wished to establish cell clones, in which ERα is ectopically expressed, forming part of a synthetic lethality screening system. Initially, we generated cell transfectants expressing a mono-cistronic ERα transcription unit, adjacent to a separate dominant selectable marker transcription unit. However, the yield of ERα expressing colonies was rather low (5-12.5%, and only about half of these displayed stable ectopic ERα expression over time. Generation and maintenance of such cell clones under minimal exposure to the ERα ligand, did not improve yield or expression stability. Indeed, other groups have also reported grave difficulties in obtaining ectopic expression of ERα in ERα-deficient breast carcinoma cells. We therefore switched to transfecting these cell lines with pERα-IRES, a plasmid vector encoding a bicistronic translation mRNA template: ERα Open Reading Frame (ORF being upstream followed by a dominant-positive selectable marker (hygro(R ORF, directed for translation from an Internal Ribosome Entry Site (IRES. Through usage of this bicistronic vector linkage system, it was possible to generate a very high yield of ERα expressing cell clones (50-100%. The stability over time of these clones was also somewhat improved, though variations between individual cell clones were evident. Our successful experience with ERα in this system may serve as a paradigm for other genes where ectopic expression meets similar hardships.

  13. Nonlinear Responses of High-rise Buildings in Seattle for Simulated Ground Motions From Giant Cascadia Subduction Earthquakes (Mw 9.2)

    Science.gov (United States)

    Yang, J.; Heaton, T. H.

    2008-12-01

    With the exception of the 2003 Tokachi-oki earthquake, strong ground recordings from large subduction earthquakes (Mw > 8.0) are meager. Furthermore there are no strong motion recordings of giant earthquakes. However, there is a growing set of high-quality broadband teleseismic recordings of large and giant earthquakes. In this poster, we use recordings from the 2003 Tokachi-oki (Mw 8.3) earthquake as empirical Green's functions to simulate the rock and soil ground motions from a scenario Mw 9.2 subduction earthquake on Cascadia subduction zone in the frequency band of interest to flexible and large- scale buildings (0.075 to 1 Hz). The effect of amplification by the Seattle basin is considered by using a basin response Green's function which is derived from deconvolving the teleseismic waves recorded at rock sites from soil sites at the SHIP02 experiment. These strong ground motions are used to excite simulation of the fully nonlinear seismic responses of 20-story and 6-story steel moment-frame buildings designed according to both the U.S. 1994 UBC and also the Japanese building code published in 1987. We consider several realizations of the hypothetical subduction earthquake; the down-dip limit of rupture is of particular importance to the simulated ground motions in Seattle. If slip is assumed to be limited to offshore regions, then the building simulations indicate that the building responses are mostly in the linear range. However, our simulation shows that buildings with brittle welds would collapse for rupture models where rupture extends beneath the Olympic Mountains. The ground motions all have very long durations (more than 4 minutes), and our building simulations should be considered as a minimum estimate since we have used a very simple model of degradation of the structure.

  14. Volcanic rocks cored on hess rise, Western Pacific Ocean

    Science.gov (United States)

    Vallier, T.L.; Windom, K.E.; Seifert, K.E.; Thiede, Jorn

    1980-01-01

    Large aseismic rises and plateaus in the western Pacific include the Ontong-Java Plateau, Magellan Rise, Shatsky Rise, Mid-Pacific Mountains, and Hess Rise. These are relatively old features that rise above surrounding sea floors as bathymetric highs. Thick sequences of carbonate sediments overlie, what are believed to be, Upper Jurassic and Lower Cretaceous volcanic pedestals. We discuss here petrological and tectonic implications of data from volcanic rocks cored on Hess Rise. The data suggest that Hess Rise originated at a spreading centre in the late early Cretaceous (Aptian-Albian stages). Subsequent off-ridge volcanism in the late Albian-early Cenomanian stages built a large archipelago of oceanic islands and seamounts composed, at least in part, of alkalic rocks. The volcanic platform subsided during its northward passage through the mid-Cretaceousequatorial zone. Faulting and uplift, and possibly volcanism, occurred in the latest Cretaceous (Campanian-Maastrichtian stages). Since then, Hess Rise continued its northward movement and subsidence. Volcanic rocks from holes drilled on Hess Rise during IPOD Leg 62 (Fig. 1) are briefly described here and we relate the petrological data to the origin and evolution of that rise. These are the first volcanic rocks reported from Hess Rise. ?? 1980 Nature Publishing Group.

  15. Rising Threat; Bonsai.

    Science.gov (United States)

    Aksel, Gokhan; Bozan, Oner; Kayaci, Mine; Guneysel, Ozlem; Sezgin, Seckin Bahar

    2015-06-01

    In recent years, and especially in the past few months, the number of synthetic cannabinoid (bonsai) users has increased in our country. The aim of this study was to draw attention to the consumption of bonsai among young people and reveal the demographic and basic clinical characteristics of these users. This was a retrospective study conducted at the Ümraniye Training and Research Hospital. All of the adult patients (≥18 year old) with synthetic cannabinoid intoxication who presented to the Emergency Department throughout the two years of the study (July 1(st) 2012-June 30(th) 2014) were enrolled. The frequencies were given as the median and inter-quartile range). 197 patients were included in this study, with 190 male patients (96.4%) and 7 (3.6%) female patients. Two of the four hospitalized patients were exitus, 52 left on their own will and a total of 141 patients were discharged after 6-12 hours of observation in the ED. The use of synthetic cannabinoids (bonsai) in the recent years, especially in the summer months of 2014 was investigated in this study. Although these patients can have a benign clinical course, the process can also be fatal. It should especially be noted that patients with depressed respiration, low GCS scores and high PaCO2 values are at higher risk for mortality and the necessity of early intubation should be kept in mind.

  16. Rising to the Challenge

    Directory of Open Access Journals (Sweden)

    Xiaoping Li

    2015-06-01

    Full Text Available Writing is recognized as a vital skill in education and the workplace; students in the United States finishing K-12 schooling are expected to be competent writers. Yet, the Nation’s Report Card found that U.S. high school graduates coming into the workforce are particularly deficient in writing skills. Teachers serve as a crucial link in the move to improve literacy skills of K-12 students; however, teachers themselves are underprepared to be writers and writing teachers. Therefore, there is an urgent need to improve teachers’ writing skills and skills of teaching writing to improve K-12 students’ writing skills in the United States. This qualitative study examined the process-based writing project experienced by 22 practicing teachers through their reflective practices in a graduate capstone class. In particular, this study explored the challenges the teachers faced and the lessons they learned through the recursive phases of writing: planning, drafting, revising, editing, conferring, and publishing. The triangulation of the researchers’ field notes, teachers’ daily reflections, and informal interviews between the instructor and the teachers indicated that the challenges the teachers faced and the lesson they learned through the process-based writing project were phase specific. On the completion of the writing project, the participating teachers (a developed a deep understanding of process-based writing; (b learned new skills of planning, drafting, revising, editing, and sharing; and (c were more confident as writers themselves and as writing teachers for their students.

  17. Exposure to residential radon and lung cancer in Spain: a population-based case-control study.

    Science.gov (United States)

    Barros-Dios, Juan Miguel; Barreiro, María Amparo; Ruano-Ravina, Alberto; Figueiras, Adolfo

    2002-09-15

    Although high radon concentrations have been linked to increased risk of lung cancer by both experimental studies and investigations of underground miners, epidemiologic studies of residential radon exposure display inconsistencies. The authors therefore decided to conduct a population-based case-control study in northwest Spain to determine the risk of lung cancer associated with exposure to residential radon. The study covered a total of 163 subjects with incident lung cancer and a population sample of 241 cancer-free subjects since 1992-1994. Odds ratios for radon were estimated using logistic regression adjusted for sex, age, lifetime tobacco use, family history, and habitat. The adjusted odds ratios for the second, third, and fourth quartiles of radon (breakpoints: 37.0, 55.2, and 148.0 Bq/m(3)) were 2.73 (95% confidence interval (CI): 1.12, 5.48), 2.48 (95% CI: 1.29, 6.79), and 2.96 (95% CI: 1.29, 6.79), respectively. An additive synergic effect between radon and tobacco was found. The results from this study suggest that, even at concentrations far below official guideline levels, radon may lead to a 2.5-fold rise in the risk of lung cancer. Furthermore, the synergy found between smoking and radon may prove useful when it comes to drafting public health recommendations.

  18. Tracing residential mobility during the Merovingian period: An isotopic analysis of human remains from the Upper Rhine Valley, Germany.

    Science.gov (United States)

    Schuh, Christine; Makarewicz, Cheryl A

    2016-09-01

    Written sources have provided information about the rise of Merovingian power and their territorial conquests after the disintegration of the Western Roman Empire, but the extent to which altered power relations in the newly annexed territories reshaped regional and local communities is poorly understood. The early medieval cemetery of Dirmstein, located in the Upper Rhine Valley, is one of the rare sites bearing archeological evidence of simultaneous use by an indigenous community and newcomers from outside the Merovingian core area, and it offers the opportunity to investigate residential mobility at the former Roman Rhine frontier during the Merovingian period. We conducted strontium, oxygen, and carbon isotope analyses on human tooth enamel recovered from 25 sixth century inhumations at the Dirmstein cemetery to establish the presence of newcomers to the Upper Rhine region. The low δ(13) C values exhibited by the Dirmstein individuals revealed ingestion of a C3 terrestrial based diet, with no detectable contribution of C4 plants, which indicates the absence of individuals from regions where a C4 -based diet was common. Human (87) Sr/(86) Sr values well outside the local range of bioavailable strontium, in combination with low δ(18) O values, suggest a notable presence of newcomers from more eastern or high altitude regions. The isotopic evidence indicates that residential mobility was important and new settlers, most likely from outside the Merovingian core area, contributed to the settlement of the northern Upper Rhine Valley during the sixth century AD. © 2016 Wiley Periodicals, Inc.

  19. Rising Threat; Bonsai

    Directory of Open Access Journals (Sweden)

    Gokhan AKSEL

    2015-06-01

    Full Text Available SUMMARY: Objectives: In recent years, and especially in the past few months, the number of synthetic cannabinoid (bonsai users has increased in our country. The aim of this study was to draw attention to the consumption of bonsai among young people and reveal the demographic and basic clinical characteristics of these users. Methods: This was a retrospective study conducted at the Ümraniye Training and Research Hospital. All of the adult patients (≥18 year old with synthetic cannabinoid intoxication who presented to the Emergency Department throughout the two years of the study (July 1st 2012–June 30th 2014 were enrolled. The frequencies were given as the median and inter-quartile range. Results: 197 patients were included in this study, with 190 male patients (96.4% and 7 (3.6% female patients. Two of the four hospitalized patients were exitus, 52 left on their own will and a total of 141 patients were discharged after 6-12 hours of observation in the ED. Conclusions: The use of synthetic cannabinoids (bonsai in the recent years, especially in the summer months of 2014 was investigated in this study. Although these patients can have a benign clinical course, the process can also be fatal. It should especially be noted that patients with depressed respiration, low GCS scores and high PaCO2 values are at higher risk for mortality and the necessity of early intubation should be kept in mind. Key words: Cannabinoid receptor agonists, emergency medicine

  20. Surface Tension and Capillary Rise

    Science.gov (United States)

    Walton, Alan J.

    1972-01-01

    Discussion of the shortcomings of textbook explanations of surface tension, distinguishing between concepts of tension and capillary rise. The arguments require only a clear understanding of Newtonian mechanics, notably potential energy. (DF)

  1. Looking For Value in All The Wrong Places. Toward Expanded Consideration of Green and High Performance Attributes in Non-residential Property Appraisals in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Evan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-10-21

    Large numbers of commercial buildings have sought to improve their energy and environmental performance, with half of all leasable U.S. offices now designated at some level of “green”. All proper/es fall somewhere on the green/high-­performance spectrum (above and below average) whether or not they bear a formal label or ra/ng.1 Variations in the level of performance can either positively or negatively influence value. This component of value can be shaped by many factors, from utility costs to tenant/owner preferences that translate into income (rent levels, vacancy rates, lease-­up /mes, etc.). Occupant perceptions of indoor environmental quality are another potential influence on value. While there has been little uptake of this thinking by practicing appraisers, the increased prevalence of green/HP practices combined with concerns about appraiser competency are compelling the industry to adapt their traditional techniques to this new driver of value. However, the overly narrow focus of policymakers on appraisal of labeled or rated exemplary buildings (e.g., LEED or ENERGY STAR Certified) represents a significant missed opportunity. Any level of green or energy performance can in fact influence value, including below-­average performance (a.k.a. “brown discount”), irrespec/ve of whether or not the building has been formally rated. Another surmountable challenge is the limitations to non-­appraisers’ understanding of the appraisal process (and constraints therein). A crucial byproduct of this is unrealistic expectations of what appraisers can and will do in the marketplace. This report identifies opportunities for catalyzing improvement of the green/HP appraisal process, which apply to all involved actors—from owner, report-­ordering client, the appraiser, and the appraisal reviewer—and fostering more demand for appraisals that recognize green/HP property attributes. The intended audience is primarily the public policy community and other

  2. Investigate and Comparsion Self-Esteem and Happiness Among Residential and Non-Residential Old People

    Directory of Open Access Journals (Sweden)

    Zakieh Nasiri

    2012-07-01

    Full Text Available Objectives: The main aim of this study was to investigate and to compare elderly happiness and self-esteem among residential and non-residential. Methods & Materials: This research was designed as descriptive. Two groups were selected in convenience method. Member of residential elderly (416 elderly were chosen based on Morgan Table. Hundred-twenty elderly, 60 residential (30 men and 30 women and 60 non-residential (30 men and 30 women were chosen for study. Data used the three questionnaires, like Demographic questionnaires, Oxford Happiness Inventory and Self-esteem Scale’s Rozenberg. Data were gathered and analyzed with Pearson test, t-student test. Results: The results were indicated that a significant relationship between happiness and self-esteem, among residential and non- residential old people. The findings showed significant difference in happiness, self-esteem among residential and home participants in both groups (P<0.01. Conclusion: The results were showed that a significant relationship between social support and self-esteem, among residential and non-residential old people. Also, the results were indicated that significant difference between social support. In general, residential participants had lower social support and self-esteem than non-residential participants.

  3. Patterns of Residential Segregation.

    Science.gov (United States)

    Louf, Rémi; Barthelemy, Marc

    2016-01-01

    The spatial distribution of income shapes the structure and organisation of cities and its understanding has broad societal implications. Despite an abundant literature, many issues remain unclear. In particular, all definitions of segregation are implicitely tied to a single indicator, usually rely on an ambiguous definition of income classes, without any consensus on how to define neighbourhoods and to deal with the polycentric organization of large cities. In this paper, we address all these questions within a unique conceptual framework. We avoid the challenge of providing a direct definition of segregation and instead start from a definition of what segregation is not. This naturally leads to the measure of representation that is able to identify locations where categories are over- or underrepresented. From there, we provide a new measure of exposure that discriminates between situations where categories co-locate or repel one another. We then use this feature to provide an unambiguous, parameter-free method to find meaningful breaks in the income distribution, thus defining classes. Applied to the 2014 American Community Survey, we find 3 emerging classes-low, middle and higher income-out of the original 16 income categories. The higher-income households are proportionally more present in larger cities, while lower-income households are not, invalidating the idea of an increased social polarisation. Finally, using the density-and not the distance to a center which is meaningless in polycentric cities-we find that the richer class is overrepresented in high density zones, especially for larger cities. This suggests that density is a relevant factor for understanding the income structure of cities and might explain some of the differences observed between US and European cities.

  4. The rise and fall of spinning tops

    Science.gov (United States)

    Cross, Rod

    2013-04-01

    The motion of four different spinning tops was filmed with a high-speed video camera. Unlike pointed tops, tops with a rounded peg precess initially about a vertical axis that lies well outside the top, and then spiral inward until the precession axis passes through a point close to the center-of-mass. The center-of-mass of a top with a rounded peg can rise as a result of rolling rather than sliding friction, contrary to the explanation normally given for the rise of spinning tops. A tippe top was also filmed and was observed to jump vertically off a horizontal surface several times while the center-of-mass was rising, contrary to the usual assumption that the normal reaction force on a tippe top remains approximately equal to its weight. It was found that the center-of-mass of a tippe top rises as a result of rolling friction at low spin frequencies and as a result of sliding friction at high spin frequencies. It was also found that, at low spin frequencies, a tippe top can precess at two different frequencies simultaneously.

  5. Transitioning to Low-GWP Alternatives in Residential and Light Commercial Air Conditioning

    Science.gov (United States)

    This fact sheet provides current information on low global warming potential (GWP) alternatives for new equipment in residential and light commercial air conditioning (AC), in lieu of high-GWP hydrofluorocarbons (HFCs).

  6. Residential greenness is differentially associated with childhood allergic rhinitis and aeroallergen sensitization in seven birth cohorts

    NARCIS (Netherlands)

    Fuertes, E.; Markevych, I.; Bowatte, G.; Gruzieva, O.; Gehring, U.; Becker, A.; Berdel, D.; von Berg, A.; Bergstrom, A.; Brauer, M.; Brunekreef, B.; Brueske, I.; Carlsten, C.; Chan-Yeung, M.; Dharmage, S. C.; Hoffmann, B.; Kluemper, C.; Koppelman, G. H.; Kozyrskyj, A.; Korek, M.; Kull, I.; Lodge, C.; Lowe, A.; MacIntyre, E.; Pershagen, G.; Standl, M.; Sugiri, D.; Wijga, A.; Heinrich, J.

    2016-01-01

    Background: The prevalence of allergic rhinitis is high, but the role of environmental factors remains unclear. We examined cohort-specific and combined associations of residential greenness with allergic rhinitis and aeroallergen sensitization based on individual data from Swedish (BAMSE),

  7. Analysis on and Design of Smoke Control and Air Conditioning System of A Super High-rise Building%某超高层建筑防排烟及空调系统分析与设计

    Institute of Scientific and Technical Information of China (English)

    杨稀童

    2015-01-01

    Based on a practical case, the problems of smoke control and the air conditioning system in a super high-rise building design are analyzed, with water system partition and water pump control strategy analyzed in detail. And the optimal solution for the project is finally obtained.%该文结合工程实例,分析在超高层建筑设计时应注意的防排烟及空调系统的问题,并重点分析空调水系统分区、水泵控制策略,得出该项目水系统分区及水泵控制的最优方案。

  8. Comparison of real-time instruments and gravimetric method when measuring particulate matter in a residential building.

    Science.gov (United States)

    Wang, Zuocheng; Calderón, Leonardo; Patton, Allison P; Sorensen Allacci, MaryAnn; Senick, Jennifer; Wener, Richard; Andrews, Clinton J; Mainelis, Gediminas

    2016-11-01

    This study used several real-time and filter-based aerosol instruments to measure PM 2.5 levels in a high-rise residential green building in the Northeastern US and compared performance of those instruments. PM 2.5 24-hr average concentrations were determined using a Personal Modular Impactor (PMI) with 2.5 µm cut (SKC Inc., Eighty Four, PA) and a direct reading pDR-1500 (Thermo Scientific, Franklin, MA) as well as its filter. 1-hr average PM 2.5 concentrations were measured in the same apartments with an Aerotrak Optical Particle Counter (OPC) (model 8220, TSI, Inc., Shoreview, MN) and a DustTrak DRX mass monitor (model 8534, TSI, Inc., Shoreview, MN). OPC and DRX measurements were compared with concurrent 1-hr mass concentration from the pDR-1500. The pDR-1500 direct reading showed approximately 40% higher particle mass concentration compared to its own filter (n = 41), and 25% higher PM 2.5 mass concentration compared to the PMI 2.5 filter. The pDR-1500 direct reading and PMI 2.5 in non-smoking homes (self-reported) were not significantly different (n = 10, R 2 = 0.937), while the difference between measurements for smoking homes was 44% (n = 31, R 2 = 0.773). Both OPC and DRX data had substantial and significant systematic and proportional biases compared with pDR-1500 readings. However, these methods were highly correlated: R 2 = 0.936 for OPC versus pDR-1500 reading and R 2 = 0.863 for DRX versus pDR-1500 reading. The data suggest that accuracy of aerosol mass concentrations from direct-reading instruments in indoor environments depends on the instrument, and that correction factors can be used to reduce biases of these real-time monitors in residential green buildings with similar aerosol properties. This study used several real-time and filter-based aerosol instruments to measure PM 2.5 levels in a high-rise residential green building in the northeastern United States and compared performance of those instruments. The data show that while the use of real

  9. Active mass damper system for high-rise buildings using neural oscillator and position controller: sinusoidally varying desired displacement of auxiliary mass intended for reduction of maximum control force

    Science.gov (United States)

    Iba, D.; Hongu, J.; Sasaki, T.; Shima, S.; Nakamura, M.; Moriwaki, I.

    2017-04-01

    Reducing vibration of high-rise structures under earthquake load has been the subject of considerable efforts in Japan. Relevant researches about vibration energy dissipation devices for buildings have been undertaken. An active mass damper is one of the well-known vibration control devices. Despite the accumulation of much knowledge of control design methods for the system, application of the devices to high-rise structures under earthquake load is challenging, because the active mass dampers have one serious disadvantage about stroke limitation of the auxiliary mass. In this study, we have proposed a new control system, which had a neural oscillator and position controller, to solve this problem. The objective of this paper is to improve the vibration control performance of the proposed active mass damper system. The previous method generated rectangular waves as the desired displacement, whose amplitude is varied in accordance with the vibration responses of a structure excited by earthquakes. Furthermore, the gains of the position controller, which derives the auxiliary mass to the desired displacement, have been designed in consideration of response reduction of the structure. However, the generated rectangular desired displacement was not adequate to reduce the maximum acceleration responses of the structure, because the driving force for the auxiliary mass generates excessive amounts of acceleration as the direction of the desired displacement is switched. Thus, this paper proposes a new method, which generates sinusoidal varying desired displacement for the auxiliary mass of the active mass damper system to reduce the acceleration response of structures. The results of numerical simulation showed that the proposed method in this work was effective for improving the control performance.

  10. Chapter 17: Residential Behavior Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, James [Cadmus Group, Waltham, MA (United States); Todd, Annika [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-01-01

    Residential behavior-based (BB) programs use strategies grounded in the behavioral social sciences to influence household energy use. Strategies may include providing households with real-time or delayed feedback about their energy use; supplying energy-efficiency education and tips; rewarding households for reducing their energy use; comparing households to their peers; and establishing games, tournaments, and competitions. BB programs often target multiple energy end uses and encourage energy savings, demand savings, or both. Savings from BB programs are usually a small percentage of energy use, typically less than 5%.

  11. Floor heating of high-rise buildings

    Energy Technology Data Exchange (ETDEWEB)

    Korff, H.K.

    1979-01-01

    When planning a large housing estate near Aschaffenburg in the years from 1962 to 1965, the decision was made to use electric floor heating fed mainly by off-peak electricity. In order to keep the cost of heating at an acceptable level and for better use of the storage effect, a type of thermal insulation was installed which was far in advance of the methods used at the time. The heat transmission coefficient of the external walls was later on found to be 0.88 W/m/sup 2/K. This value fully meets the requirements as specified in the thermal insulation ordinance which came into force in 1977. A cost analysis has shown that the heating costs are not higher than in similar buildings equipped with conventional heating systems.

  12. Performance-based potential for residential energy efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Performance-based potential for residential energy efficiency

    2013-01-15

    Energy performance contracts (EPCs) have proven an effective mechanism for increasing energy efficiency in nearly all sectors of the economy since their introduction nearly 30 years ago. In the modern form, activities undertaken as part of an EPC are scoped and implemented by experts with specialized technical knowledge, financed by commercial lenders, and enable a facility owner to limit risk and investment of time and resources while receiving the rewards of improved energy performance. This report provides a review of the experiences of the US with EPCs and discusses the possibilities for the residential sector to utilize EPCs. Notably absent from the EPC market is the residential segment. Historically, research has shown that the residential sector varies in several key ways from markets segments where EPCs have proven successful, including: high degree of heterogeneity of energy use characteristics among and within households, comparatively small quantity of energy consumed per residence, limited access to information about energy consumption and savings potential, and market inefficiencies that constrain the value of efficiency measures. However, the combination of recent technological advances in automated metering infrastructure, flexible financing options, and the expansion of competitive wholesale electricity markets to include energy efficiency as a biddable supply-side resource present an opportunity for EPC-like efforts to successfully engage the residential sector, albeit following a different model than has been used in EPCs traditionally.(Author)

  13. The post-evaluation of green residential building in Ningxia

    Science.gov (United States)

    Wu, Yunna; Wang, Zhen

    2017-06-01

    Green residential buildings are concerned by more and more people. However, the development of green residential buildings has been limited due to the single-standard requirements and lack of the multi-objective performance. At same time, the evaluation criteria system of green residential building is not comprehensive enough. So first of all, using SPSS software, residents questionnaire surveys are figured and found that the judge of experts and residents about the green elements is inconsistent, so the owners’ satisfaction is included in the post-evaluation criterial systems of green residential building from five aspects-the preliminary work of construction, construction process, economic, social benefits and owners satisfaction in Ningxia area, combined with expert interviews. Secondly, in the post-evaluation, it is difficult for many experts judgment matrix to meet the requirement of consistency, in this paper using MATLAB program, judgment matrix consistency is adjusted. And the weights of the criteria and sub-criteria and experts weights using group AHP method are determined. Finally, the grey clustering method is used to establish the post-evaluation model and the real case of Sai-shang project is carried out. It shows that the result obtained by using the improved criteria system and method in this paper is in a high degree of agreement with the actual result.

  14. Residential Solar Power and the Physics Teacher

    Science.gov (United States)

    Carpenter, David

    2007-10-01

    The roof of my house sports one of the largest residential photovoltaic arrays in Ohio. It produces all of the electricity for my house and family of four. With state and federal incentives, it cost less to install than the price of a new car. It will pay for itself within the warrantee period. A picture of my house with solar panels is the background on my classroom computer. I am the physics teacher at Hayes High School in Delaware, Ohio. I don't need a formal curriculum. Sooner or later my students start asking questions. They even ask the exact same questions that adults do. The inverter for my PV system sends performance data to my computer. I post this on my website, which takes it into my classroom. This sparks conversation on a whole variety of topics, from sun angles to energy, electricity, technology and climate studies.

  15. Probabilistic Quantification of Potentially Flexible Residential Demand

    DEFF Research Database (Denmark)

    Kouzelis, Konstantinos; Mendaza, Iker Diaz de Cerio; Bak-Jensen, Birgitte

    2014-01-01

    of residential consumers. The procedure is based on non-flexible consumer clustering and subsequent statistical analysis. Consequently, the power consumption pattern of a flexible consumer is compared to a 3D probability distribution created by the previously referred methodology. The results show a strong......The balancing of power systems with high penetration of renewable energy is a serious challenge to be faced in the near future. One of the possible solutions, recently capturing a lot of attention, is demand response. Demand response can only be achieved by power consumers holding loads which allow...... them to modify their normal power consumption pattern, namely flexible consumers. However flexibility, despite being constantly mentioned, is usually not properly defined and even rarer quantified. This manuscript introduces a methodology to identify and quantify potentially flexible demand...

  16. Rise, stagnation, and rise of Danish women's life expectancy

    DEFF Research Database (Denmark)

    Lindahl-Jacobsen, Rune; Rau, Roland; Jeune, Bernard

    2016-01-01

    or later. Because it is difficult to disentangle period effects from cohort effects, demographers, epidemiologists, actuaries, and other population scientists often disagree about cohort effects' relative importance. In particular, some advocate forecasts of life expectancy based on period trends; others...... favor forecasts that hinge on cohort differences. We use a combination of age decomposition and exchange of survival probabilities between countries to study the remarkable recent history of female life expectancy in Denmark, a saga of rising, stagnating, and now again rising lifespans. The gap between...

  17. Exploring the unprecedented rise in Danish burglary

    DEFF Research Database (Denmark)

    Sorensen, David W.M.

    2012-01-01

    After 18 years of relative stability, the number of residential burglaries reported to Danish police suddenly shot up by 65% between 2005 and 2009. As of 2011, burglary rates remained 30% higher than the 18-year average prior to the increase. Little solid evidence exists as to why residential bur...

  18. Residential ventilation standards scoping study

    Energy Technology Data Exchange (ETDEWEB)

    McKone, Thomas E.; Sherman, Max H.

    2003-10-01

    The goals of this scoping study are to identify research needed to develop improved ventilation standards for California's Title 24 Building Energy Efficiency Standards. The 2008 Title 24 Standards are the primary target for the outcome of this research, but this scoping study is not limited to that timeframe. We prepared this scoping study to provide the California Energy Commission with broad and flexible options for developing a research plan to advance the standards. This document presents the findings of a scoping study commissioned by the Public Interest Energy Research (PIER) program of the California Energy Commission to determine what research is necessary to develop new residential ventilation requirements for California. This study is one of three companion efforts needed to complete the job of determining the ventilation needs of California residences, determining the bases for setting residential ventilation requirements, and determining appropriate ventilation technologies to meet these needs and requirements in an energy efficient manner. Rather than providing research results, this scoping study identifies important research questions along with the level of effort necessary to address these questions and the costs, risks, and benefits of pursuing alternative research questions. In approaching these questions and corresponding levels of effort, feasibility and timing were important considerations. The Commission has specified Summer 2005 as the latest date for completing this research in time to update the 2008 version of California's Energy Code (Title 24).

  19. Residential Electricity Consumption in Poland

    Directory of Open Access Journals (Sweden)

    Edyta Ropuszyńska-Surma

    2016-01-01

    Full Text Available Key factors influencing electricity consumption in the residential sector in Poland have been identified. A fixed-effects model was used, which includes time effects, and a set of covariates, based on the model developed by Houthakker et al. This model estimates electricity demand by using lagged values of the dependent variable along with current and lagged values of electricity prices, and other variables that affect electricity demand such as: population, economic growth, income per capita, price of related goods, etc. The model has been identified according to the research results of the authors and those obtained by Bentzen and Engsted. The set of covariates was extended to the lagged electricity price given by a tariff (taken from two years previous to the time of interest and heating degree days index, a very important factor in European Union countries, where the climate is temperate. The authors propose four models of residential electricity demand, for which a confidence interval of 95% has been assumed. Estimation was based on Polish quarterly data for the years 2003-2013. (original abstract

  20. Using Machine Learning and Data Analysis to Improve Customer Acquisition and Marketing in Residential Solar

    Energy Technology Data Exchange (ETDEWEB)

    Sigrin, Benjamin O [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-10-18

    High customer acquisition costs remain a persistent challenge in the U.S. residential solar industry. Effective customer acquisition in the residential solar market is increasingly achieved with the help of data analysis and machine learning, whether that means more targeted advertising, understanding customer motivations, or responding to competitors. New research by the National Renewable Energy Laboratory, Sandia National Laboratories, Vanderbilt University, University of Pennsylvania, and the California Center for Sustainable Energy and funded through the U.S. Department of Energy's Solar Energy Evolution and Diffusion (SEEDS) program demonstrates novel computational methods that can help drive down costs in the residential solar industry.

  1. Credit Scores, Race, and Residential Sorting

    Science.gov (United States)

    Nelson, Ashlyn Aiko

    2010-01-01

    Credit scores have a profound impact on home purchasing power and mortgage pricing, yet little is known about how credit scores influence households' residential location decisions. This study estimates the effects of credit scores on residential sorting behavior using a novel mortgage industry data set combining household demographic, credit, and…

  2. Children with ADHD in Residential Care

    Science.gov (United States)

    Casey, Kathryn J.; Hagaman, Jessica L.; Trout, Alexandra L.; Reid, Robert; Chmelka, Beth; Thompson, Ronald W.; Daly, Daniel L.

    2008-01-01

    Little is known about the characteristics or functioning of children with ADHD in residential care as compared to their non-ADHD peers. This study evaluated data on 538 children with (n = 125) and without (n = 413) ADHD in residential care to determine demographic, mental health, behavioral, and treatment (i.e., medication use) characteristics.…

  3. Urban and suburban lifestyles and residential preferences in a highly urbanized society Urbane en suburbane leefstijlen en woonvoorkeuren in een samenleving onder verstedelijkingsdruk. Resultaten op basis van case onderzoek in Gent (Vlaanderen, België

    Directory of Open Access Journals (Sweden)

    Georges Allaert

    2012-12-01

    Full Text Available It is widely recognized that cities nowadays are confronted with (new challenges like segregation and suburbanisation. This paper explores the idea that these processes are related with residential choices (or preferences made by residents with divergent lifestyles and value patterns. The paper focuses on differences between urban and suburban lifestyles and residential preferences. Firstly the concept of lifestyles in general, and urban and suburban lifestyles more specifically, are approached. Secondly the results of a quantitative survey amongst residents within four neighbourhoods in the Ghent Region, a city in Belgium, are presented. This survey confirms that residents of urban and suburban zones have divergent lifestyles, but only for behavioural aspects, such as : private property protection, status behaviour and ecological behaviour. This results however in a social-spatial inequality and polarization between the urban centres and the suburban fringe. The shared aims amongst urban as well as suburban residents for a more secure residential environment and the ideal of the detached single-family house with private garden situated within a purely residential area, were identified as drivers for future suburban migrations. These residential preferences might cause (further suburbanisation but do not need to lead to segregated social communities, since living with peers does not seem to be a driver for migration in Flanders, Belgium.Heel wat steden worden vandaag de dag geconfronteerd met een toenemende of voortschrijdende segregatie en suburbanisatie. Deze maatschappelijke en ruimtelijke processen worden in deze paper in verband gebracht met concrete woonkeuzes of -voor­keuren van de bewoners en met hun specifieke leefstijlen. In eerste instantie wordt in de paper stilgestaan bij het concept leefstijl, waarbij een onderscheid wordt gemaakt tussen latente leefstijlen, gerelateerd aan normen, waarden en karaktereigenschappen van de

  4. Assessment of Alternative Scenarios for CO2 Reduction Potential in the Residential Building Sector

    Directory of Open Access Journals (Sweden)

    Young-Sun Jeong

    2017-03-01

    Full Text Available The South Korean government announced its goals of reducing the country’s CO2 emissions by up to 30% below the business as usual (BAU projections by 2020 in 2009 and 37% below BAU projections by 2030 in 2015. This paper explores the potential energy savings and reduction in CO2 emissions offered by residential building energy efficiency policies and plans in South Korea. The current and future energy consumption and CO2 emissions in the residential building were estimated using an energy–environment model from 2010 to 2030. The business as usual scenario is based on the energy consumption characteristic of residential buildings using the trends related to socio-economic prospects and the number of dwellings. The alternative scenarios took into account energy efficiency for new residential buildings (scenario I, refurbishment of existing residential buildings (scenario II, use of highly efficient boilers (scenario III, and use of a solar thermal energy system (scenario IV. The results show that energy consumption in the residential building sector will increase by 33% between 2007 and 2030 in the BAU scenario. Maximum reduction in CO2 emissions in the residential building sector of South Korea was observed by 2030 in scenario I. In each alternative scenario analysis, CO2 emissions were 12.9% lower than in the business as usual scenario by the year 2030.

  5. [Residential radon and lung cancer. An ecologic study in Galicia, Spain].

    Science.gov (United States)

    Barbosa-Lorenzo, Raquel; Ruano-Ravina, Alberto; Cerdeira Caramés, Sara; Barros-Dios, Juan Miguel

    2015-04-08

    Residential radon is the second cause of lung cancer and the first in never smokers. Galicia is a high radon emission area. The objective of this study is to analyze the relationship between municipal lung cancer mortality and residential radon in Galician municipalities. We performed an ecologic study including 192 municipalities with at least 3 residential radon measurements. The observed number of lung cancer deaths was obtained from the Galician Mortality Registry. Afterwards, we calculated the standardized mortality ratios (SMRs) of lung cancer for males and females for the period comprising 1980-2009. Median municipal residential radon concentrations were correlated with lung cancer SMRs. Median residential radon concentration for the included municipalities was 75 Bq/m(3), with an interquartile range of 40.7 to 154 Bq/m(3). The correlation between lung cancer SMRs and municipal radon concentration was statistically significant for males (P=.023) whereas it did not reach statistical significance for females (P=.087). There exists an association between municipal residential radon and lung cancer mortality in Galicia for males, though for women the association is not statistically significant. These results suggest that residential radon could raise the risk of lung cancer in males, though for females no association is evident. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  6. Indoor Noise Loading in Residential Prefabricated Buildings

    Science.gov (United States)

    Kraus, Michal; Juhásová Šenitková, Ingrid

    2017-10-01

    Quality on indoor environment is among others also defined by an acoustic comfort and noise emissions. The indoor noise loading in the residential prefabricated buildings is specific problem related to structural design of these buildings. Problems with noise level of sanitary systems are mostly associated with hydraulic shock such as water distribution and sewage drainage. Another very common cause of excessive noise is also flushing the toilet or water fall on enamelled steel (bath or shower). This paper aims to analyse the acoustic properties in the residential prefabricated buildings. Sanitary core of the assessed apartment is in original condition without any alterations. The sanitary core is based on a formica (high-pressure laminate). The study discusses the maximum sound levels in the three assessed rooms for the three different noise sources. The values of maximum noise level are measured for the corridor, bedroom and living room. Sources of noise are common activities relating to the operation of sanitary core - the toilet flush in the toilet, falling water from the shower in the bathroom and the water falling on the bottom of the kitchen sink in the kitchen. Other sources of noise are eliminated or minimized during the experiment. The digital sound level meter Testo 815 is used for measurements. The measured values of maximum sound level LA,max [dB] are adjusted by the correction coefficient. The obtained values are compared with the hygienic limits for day and night period. Night hygienic limit (30 dB) is exceeded in all the rooms for all noise sources. This limit is exceeded from 17 to 73%. The values in the bedroom and the living room meet the daily hygienic limit (40 dB). The daily limit is exceeded only in the corridor. The highest values of noise are identified for the toilet flushing.

  7. Planning of Low-rise Urban Housing Areas

    DEFF Research Database (Denmark)

    Svensson, O.

    In many countries industrialization of house building has led to the building of large, monotonous housing areas with high-rise construction. In Denmark, however, smaller, varied housing areas with low-rise construction and urban features have become predominant. This report contains guidelines...... for the planning of such housing areas....

  8. The Florence Rise, the Western Bend of the Cyprus Arc

    NARCIS (Netherlands)

    Woodside, J.M.; Mascle, J.; Zitter, T.A.C.; Limonov, A.F.; Ergun, M.; Volkonskaia, A.

    2002-01-01

    The Florence Rise is a submarine feature extending from the island of Cyprus in the southeast to the Anaximander Mountains which form the northwestern end of the Cyprus Arc south of western Turkey. The eastern Florence Rise includes a topographic high near Cyprus while its central domain displays

  9. Thermographic Inspections And The Residential Conservation Service Program (RCS)

    Science.gov (United States)

    Ward, Ronald J.

    1983-03-01

    Rhode Islanders Saving Energy (RISE) is a non-profit corporation founded in 1977 to provide Rhode Island residents with a variety of energy conservation services. Since January of 1981, it has been performing energy audits in compliance with the Department of Energy's (DOE) Residential Conservation Service Program (RCS). One aspect of the RCS program is the performance of inspections on energy conservation activities completed according to RCS installation guidelines. This paper will describe both the use and results of thermographic inspections within the RISE program. The primary objective of these inspections has been to assure the quality of the building envelope after completion of retrofit measures. Thermal anamolies have been detected that vary in size, location and probable cause. Approximately 37% of all jobs performed through RISE in conjunction with the RCS program have required remedial work as a result of problems that were identi-fied during the thermographic inspection. This percentage was much higher when infra-red inspections were conducted on "Non-RCS" retrofits. Statistics will be presented that provide an interesting insight on the quality of retrofit work when performed in associa-tion with a constant inspection process.

  10. Exploring the Impact and Implications of Residential Mobility: From the Neighborhood to the School

    Directory of Open Access Journals (Sweden)

    Robin L. Ersing

    2009-03-01

    Full Text Available This cross-sectional study examines residential relocation among a cohort of 495 fifth graders in one urban community in the Southeastern U.S. The impact of residential mobility is discussed in relation to student/family outcomes as well as the stressors placed upon schools. Results support previous findings which suggest residential relocation is correlated with academic problems. In addition, highly mobile students are twice as likely to be referred by teachers for disciplinary intervention and families are five times more likely than their residentially stable counterparts to be involved with child protective services. Implications from this study address the need for school systems, including school social workers, to look beyond the classroom to understand and respond to the needs of highly mobile families.

  11. Gis Based Analysis For Suitability Location Finding In The Residential Development Areas Of Greater Matara Region

    Directory of Open Access Journals (Sweden)

    H.K.G.M Madurika

    2017-02-01

    Full Text Available Urban Planning and Land utilization for the Residential is one of crucial factors in high density Cities. Many theories in Planning explain the Residential areas are moving to periphery areas in cities by its commercial development. Martara is one of developing city in Southern Sri Lanka and Residential land value are comparative high in city sub urban areas. In this study it is examined that where is the best locations for residential development in Grater Matara Region by using five criteria. GIS based Multi Criteria Method MCE method have been applied to find the suitable locations. The results of analysis have been shown that there are 5378.99 hectares area suitable within study area and however extremely importance areas only 1.40 hectares accordingly given criteria but very strongly importance and importance category have 1560.51 and 2468.22 respectively.

  12. Residential architecture of George Pavlovic Kovalevsky in interwar Belgrade

    Directory of Open Access Journals (Sweden)

    Vuksanović-Macura Zlata

    2016-01-01

    Full Text Available George Pavlovic Kovalevsky, architect and urban planner, belongs to the most significant authors who created in the period between the Two World Wars in Belgrade. Yet, his work and life have rarely been the subject of scholarly literature, while the study of his housing projects has been overlooked. This paper discusses housing projects designed by Kovalevsky mainly in collaboration with another Russian architect Vladimir Bilinski. The analysis of the projects is based on original archival plans, documents and photographs. Residential buildings designed during 1921-1923 by these two architects include small single-storey houses, multi-storey building and spacious villas. Although of different surface, volume and shape, they have some common characteristics such as: classical construction, equable aesthetic quality that followed the spirit of the late Secession or the modernized Academicism, and were designed in line with the requirements of the property-owners. Buildings created by Kovalevsky and Bilinski cannot be considered among the most important achievements of the interwar Belgrade residential architecture, but their study is important because it contributes to a better understanding and evaluation of the work of these authors, as well as the overall architectural production of that period. In a broader sense, this paper builds upon general rise in interest in the revaluation of cultural, social and historical values of residential architecture in Belgrade that was created in the late 19th and the first half of the 20th century, as an important segment of the material and immaterial cultural heritage and the identity of the city and contributes to its more adequate interpretation and preservation.

  13. Finding Rising and Falling Words

    NARCIS (Netherlands)

    Tjong Kim Sang, E.

    2016-01-01

    We examine two different methods for finding rising words (among which neologisms) and falling words (among which archaisms) in decades of magazine texts (millions of words) and in years of tweets (billions of words): one based on correlation coefficients of relative frequencies and time, and one

  14. Temperature rise of installed FCC

    Science.gov (United States)

    Hankins, J. D.

    1976-01-01

    Report discusses temperature profiles of installed FCC for wood and tile surfaces. Three-conductor FCC was tested at twice nominal current-carrying capacity over bare floor and under carpet, with result indicating that temperature rise is not a linear function of current with FCC at this level.

  15. The Impact of Subsidies on the Prevalence of Climate-Sensitive Residential Buildings in Malaysia

    Directory of Open Access Journals (Sweden)

    David T. Tan

    2017-12-01

    Full Text Available Dependence on air-conditioning (AC for residential cooling and ventilation is a health and sustainability challenge. In hot temperatures, climate-sensitive buildings (CSB can complement and/or substitute for AC usage in achieving thermal comfort. Many countries facing such conditions—particularly in tropical climates—are developing quickly, with rising populations and income creating demand for new housing and AC. This presents a window for adoption of CSB but could also result in long term lock-in of AC-dependent buildings. Here, a simple system dynamics model is used to explore the potential and limitations of subsidies to affect futures of housing stock and night-time AC usage in Malaysia. The effectiveness of subsidies in achieving high uptake of CSB and resulting health benefits is highly dependent on homebuyer willingness to pay (WTP. A detailed understanding of WTP in the Malaysian context and factors that can shift WTP is necessary to determine if CSB subsidies can be a good policy mechanism for achieving CSB uptake.

  16. Racial Residential Segregation and Disparities in Obesity among Women.

    Science.gov (United States)

    Bower, Kelly M; Thorpe, Roland J; Yenokyan, Gayane; McGinty, E Emma E; Dubay, Lisa; Gaskin, Darrell J

    2015-10-01

    The high rate of obesity among black women in the USA is a significant public health problem. However, there is limited research on the relationship between racial residential segregation and disparities in obesity, and the existing evidence is limited and results are mixed. This study examines the relationship between racial residential segregation and obesity among black and white women. We conducted this cross-sectional study by joining data from the 1999-2004 National Health and Nutrition Examination Survey with data from the 2000 US Census. Multilevel logistic regression models found that for every one-point increase in the black isolation index, there was a 1.06 (95 % confidence interval (CI) = 1.01, 1.11) times higher odds of obesity for black women. In order to address the disparately high rates of obesity among black women, health policies need to address the economic, political, and social forces that produce racially segregated neighborhoods.

  17. Insights from stakeholders of five residential smart grid pilot projects in the Netherlands

    OpenAIRE

    Obinna, U.; Joore, P.; Wauben, L.; Reinders, Angelina H.M.E.

    2016-01-01

    This paper presents insights and perceptions of stakeholders involved in the development and implementation of residential smart grid pilot projects in the Netherlands, adding to the limited information that is currently available in this area, while expectations about the potential benefits of smart grids are high. The main research questions of this study are: (1) How have some typical residential smart grid pilots in the Netherlands been set up? (2) Which stakeholders are involved in these...

  18. Rise, stagnation, and rise of Danish women's life expectancy

    DEFF Research Database (Denmark)

    Lindahl-Jacobsen, Rune; Rau, Roland; Jeune, Bernard

    2016-01-01

    Health conditions change from year to year, with a general tendency in many countries for improvement. These conditions also change from one birth cohort to another: some generations suffer more adverse events in childhood, smoke more heavily, eat poorer diets, etc., than generations born earlier...... favor forecasts that hinge on cohort differences. We use a combination of age decomposition and exchange of survival probabilities between countries to study the remarkable recent history of female life expectancy in Denmark, a saga of rising, stagnating, and now again rising lifespans. The gap between...... female life expectancy in Denmark vs. Sweden grew to 3.5 y in the period 1975-2000. When we assumed that Danish women born 1915-1945 had the same survival probabilities as Swedish women, the gap remained small and roughly constant. Hence, the lower Danish life expectancy is caused by these cohorts...

  19. 76 FR 42688 - Updating State Residential Building Energy Efficiency Codes

    Science.gov (United States)

    2011-07-19

    ...The U.S. Department of Energy (DOE or Department) has determined that the 2009 edition of the International Code Council (ICC) International Energy Conservation Code (IECC) (2009 IECC or 2009 edition) would achieve greater energy efficiency in low-rise residential buildings than the 2006 IECC, with site energy savings estimated at 14%. Also, DOE has determined that the 2006 edition of the ICC IECC (2006 IECC or 2006 edition) would achieve greater energy efficiency than the 2003 edition of the ICC IECC (2003 IECC or 2003 edition), with site energy savings estimated at 1%. Finally, DOE has determined that the 2003 edition would not achieve greater energy efficiency than the 2000 IECC. Upon publication of this affirmative final determination, States are required to file certification statements to DOE that they have reviewed the provisions of their residential building code regarding energy efficiency and made a determination as to whether to update their code to meet or exceed the 2009 IECC. Additionally, this Notice provides guidance to States on how the codes have changed from previous versions, how to submit certifications, and how to request extensions of the deadline to submit certifications.

  20. 75 FR 54131 - Updating State Residential Building Energy Efficiency Codes

    Science.gov (United States)

    2010-09-03

    ...The Department of Energy (DOE or Department) has preliminarily determined that the 2009 version of the International Code Council (ICC) International Energy Conservation Code (IECC) would achieve greater energy efficiency in low-rise residential buildings than the 2006 IECC. Also, DOE has preliminarily determined that the 2006 version of the IECC would achieve greater energy efficiency than the 2003 IECC. Finally, DOE has preliminarily determined that the 2003 version of the IECC would not achieve greater energy efficiency than the 2000 IECC. If these determinations are finalized, States would be required to file certification statements to DOE that they have reviewed the provisions of their residential building code regarding energy efficiency and made a determination as to whether to update their code to meet or exceed the most recent code with an affirmative determination, the 2009 IECC. Additionally, this Notice provides guidance to States on how the codes have changed from previous versions, how to submit certifications, and how to request extensions of the deadline to submit certifications, should the preliminary determinations be adopted as final.