WorldWideScience

Sample records for high resolution tomography

  1. High resolution positron tomography

    International Nuclear Information System (INIS)

    Brownell, G.L.; Burnham, C.A.

    1982-01-01

    The limits of spatial resolution in practical positron tomography are examined. The four factors that limit spatial resolution are: positron range; small angle deviation; detector dimensions and properties; statistics. Of these factors, positron range may be considered the fundamental physical limitation since it is independent of instrument properties. The other factors are to a greater or lesser extent dependent on the design of the tomograph

  2. Ultra high resolution tomography

    Energy Technology Data Exchange (ETDEWEB)

    Haddad, W.S.

    1994-11-15

    Recent work and results on ultra high resolution three dimensional imaging with soft x-rays will be presented. This work is aimed at determining microscopic three dimensional structure of biological and material specimens. Three dimensional reconstructed images of a microscopic test object will be presented; the reconstruction has a resolution on the order of 1000 A in all three dimensions. Preliminary work with biological samples will also be shown, and the experimental and numerical methods used will be discussed.

  3. High resolution tomography using analog coding

    International Nuclear Information System (INIS)

    Brownell, G.L.; Burnham, C.A.; Chesler, D.A.

    1985-01-01

    As part of a 30-year program in the development of positron instrumentation, the authors have developed a high resolution bismuth germanate (BGO) ring tomography (PCR) employing 360 detectors and 90 photomultiplier tubes for one plane. The detectors are shaped as trapezoid and are 4 mm wide at the front end. When assembled, they form an essentially continuous cylindrical detector. Light from a scintillation in the detector is viewed through a cylindrical light pipe by the photomultiplier tubes. By use of an analog coding scheme, the detector emitting light is identified from the phototube signals. In effect, each phototube can identify four crystals. PCR is designed as a static device and does not use interpolative motion. This results in considerable advantage when performing dynamic studies. PCR is the positron tomography analog of the γ-camera widely used in nuclear medicine

  4. High resolution computed tomography of positron emitters

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.; Cahoon, J.L.; Huesman, R.H.; Jackson, H.G.

    1976-10-01

    High resolution computed transaxial radionuclide tomography has been performed on phantoms containing positron-emitting isotopes. The imaging system consisted of two opposing groups of eight NaI(Tl) crystals 8 mm x 30 mm x 50 mm deep and the phantoms were rotated to measure coincident events along 8960 projection integrals as they would be measured by a 280-crystal ring system now under construction. The spatial resolution in the reconstructed images is 7.5 mm FWHM at the center of the ring and approximately 11 mm FWHM at a radius of 10 cm. We present measurements of imaging and background rates under various operating conditions. Based on these measurements, the full 280-crystal system will image 10,000 events per sec with 400 μCi in a section 1 cm thick and 20 cm in diameter. We show that 1.5 million events are sufficient to reliably image 3.5-mm hot spots with 14-mm center-to-center spacing and isolated 9-mm diameter cold spots in phantoms 15 to 20 cm in diameter

  5. High resolution IVEM tomography of biological specimens

    Energy Technology Data Exchange (ETDEWEB)

    Sedat, J.W.; Agard, D.A. [Univ. of California, San Francisco, CA (United States)

    1997-02-01

    Electron tomography is a powerful tool for elucidating the three-dimensional architecture of large biological complexes and subcellular organelles. The introduction of intermediate voltage electron microscopes further extended the technique by providing the means to examine very large and non-symmetrical subcellular organelles, at resolutions beyond what would be possible using light microscopy. Recent studies using electron tomography on a variety of cellular organelles and assemblies such as centrosomes, kinetochores, and chromatin have clearly demonstrated the power of this technique for obtaining 3D structural information on non-symmetric cell components. When combined with biochemical and molecular observations, these 3D reconstructions have provided significant new insights into biological function.

  6. High resolution and high speed positron emission tomography data acquisition

    International Nuclear Information System (INIS)

    Burgiss, S.G.; Byars, L.G.; Jones, W.F.; Casey, M.E.

    1986-01-01

    High resolution positron emission tomography (PET) requires many detectors. Thus, data collection systems for PET must have high data rates, wide data paths, and large memories to histogram the events. This design uses the VMEbus to cost effectively provide these features. It provides for several modes of operation including real time sorting, list mode data storage, and replay of stored list mode data

  7. New detector developments for high resolution positron emission tomography

    International Nuclear Information System (INIS)

    Ziegler, S.I.; Pichler, B.; Lorenz, E.

    1998-01-01

    The strength of quantitative, functional imaging using positron emission tomography, specially in small animals, is limited due to the spatial resolution. Therefore, various tomograph designs employing new scintillators, light sensors, or coincidence electronic are investigated to improve resolution without losses in sensitivity. Luminous scintillators with short light decay time in combination with novel readout schemes using photomultipliers or semiconductor detectors are currently tested by several groups and are implemented in tomographs for small animals. This review summarises the state of development in high resolution positron emission tomography with a detailed description of a system incorporating avalanche photodiode arrays and small scintillation crystals. (orig.) [de

  8. Detectors for high resolution dynamic positron emission tomography

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.; Huesman, R.H.

    1985-01-01

    Tomography is the technique of producing a photographic image of an opaque specimen by transmitting a beam of x-rays or gamma rays through the specimen onto an adjacent photographic film. The image results from variations in thickness, density, and chemical composition, of the specimen. This technique is used to study the metabolism of the human brain. This article examines the design of equipment used for high resolution dynamic positron emission tomography. 27 references, 5 figures, 3 tables

  9. High resolution computed tomography of auditory ossicles

    International Nuclear Information System (INIS)

    Isono, M.; Murata, K.; Ohta, F.; Yoshida, A.; Ishida, O.; Kinki Univ., Osaka

    1990-01-01

    Auditory ossicular sections were scanned at section thicknesses (mm)/section interspaces (mm) of 1.5/1.5 (61 patients), 1.0/1.0 (13 patients) or 1.5/1.0 (33 patients). At any type of section thickness/interspace, the malleal and incudal structures were observed with almost equal frequency. The region of the incudostapedial joint and each component part of the stapes were shown more frequently at a section interspace of 1.0 mm than at 1.5 mm. The visualization frequency of each auditory ossicular component on two or more serial sections was investigated. At a section thickness/section interspace of 1.5/1.5, the visualization rates were low except for large components such as the head of the malleus and the body of the incus, but at a slice interspace of 1.0 mm, they were high for most components of the auditory ossicles. (orig.)

  10. Aspects of pulmonary histiocytosis X on high resolution computed tomography

    International Nuclear Information System (INIS)

    Costa, N.S.S.; Castro Lessa Angela, M.T. de; Angelo Junior, J.R.L.; Silva, F.M.D.; Kavakama, J.; Carvalho, C.R.R. de; Cerri, G.G.

    1995-01-01

    Pulmonary histiocytosis X is a disease that occurs in young adults and presents with nodules and cysts, mainly in upper lobes, with consequent pulmonary fibrosis. These pulmonary changes are virtually pathognomonic findings on high resolution computed tomography, that allows estimate the area of the lung involved and distinguish histiocytosis X from other disorders that also produces nodules and cysts. (author). 10 refs, 2 tabs, 6 figs

  11. COST EFFECTIVE AND HIGH RESOLUTION SUBSURFACE CHARACTERIZATION USING HYDRAULIC TOMOGRAPHY

    Science.gov (United States)

    2017-08-01

    objective of this project is to provide the DoD and its remediation contractors with the HT technology for delineating the spatial distribution of...STATEMENT Approved for public release; distribution is unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT Hydraulic Tomography ( HT ) is a high-resolution...performance of subsurface remedial actions at environmental sites. The good technical performance and cost-effectiveness of HT have been demonstrated in

  12. High resolution muon computed tomography at neutrino beam facilities

    International Nuclear Information System (INIS)

    Suerfu, B.; Tully, C.G.

    2016-01-01

    X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pion decay pipe at a neutrino beam facility and what can be achieved for momentum resolution in a muon spectrometer. Such an imaging system can be applied in archaeology, art history, engineering, material identification and whenever there is a need to image inside a transportable object constructed of dense materials

  13. Paracoccidioidomycosis: High-resolution computed tomography-pathologic correlation

    International Nuclear Information System (INIS)

    Marchiori, Edson; Valiante, Paulo Marcos; Mano, Claudia Mauro; Zanetti, Glaucia; Escuissato, Dante L.; Souza, Arthur Soares; Capone, Domenico

    2011-01-01

    Objective: The purpose of this study was to describe the high-resolution computed tomography (HRCT) features of pulmonary paracoccidioidomycosis and to correlate them with pathologic findings. Methods: The study included 23 adult patients with pulmonary paracoccidioidomycosis. All patients had undergone HRCT, and the images were retrospectively analyzed by two chest radiologists, who reached decisions by consensus. An experienced lung pathologist reviewed all pathological specimens. The HRCT findings were correlated with histopathologic data. Results: The predominant HRCT findings included areas of ground-glass opacities, nodules, interlobular septal thickening, airspace consolidation, cavitation, and fibrosis. The main pathological features consisted of alveolar and interlobular septal inflammatory infiltration, granulomas, alveolar exudate, cavitation secondary to necrosis, and fibrosis. Conclusion: Paracoccidioidomycosis can present different tomography patterns, which can involve both the interstitium and the airspace. These abnormalities can be pathologically correlated with inflammatory infiltration, granulomatous reaction, and fibrosis.

  14. Diagnosis of cholesteatoma by high resolution computed tomography

    International Nuclear Information System (INIS)

    Kakitsubata, Yousuke; Kakitsubata, Sachiko; Ogata, Noboru; Asada, Keiko; Watanabe, Katsushi; Tohno, Tetsuya; Makino, Kohji

    1988-01-01

    Three normal volunteers and 57 patients with cholesteatoma were examined by high resolution computed tomography. Serial sections were made through the temporal bone at the nasaly inclined position of 30 degree to the orbitomeatal line (semiaxial plane ; SAP). The findings of temporal bone structures in normal subjects were evaluated in SAP and axial plane (OM). Although the both planes showed good visualization, SAP showed both the eustachian tube and tympanic cavity in one slice. In cholesteatoma soft tissue masses in the tympanic cavity, mastoid air cells and Eustachian tube were demonstrated clearly by SAP. (author)

  15. High resolution X-ray tomography for stationary multiphase flows

    International Nuclear Information System (INIS)

    Schmitz, D.; Reinecke, N.; Petritsch, G.; Mewes, D.

    1998-01-01

    The high resolution which can be obtained by computer assisted tomography is used to investigate the liquid distribution and void fraction in random and structured packing. With a spatial resolution of 0.4x0.4mm 2 it is possible even to detect thin liquid films on structured packings. The experimental set-up consists of a custom-built second generation tomograph. The imaged object consists of a column filled with either a random ceramic packing of spheres or a structured metal packing. The liquid and void fraction distribution in random and structured packings with a quiescent gaseous phase is visualized. The water/air system is used. The liquid distributor consists of a perforated plate. The experimental hold-up values averaged over the column cross-section are in good agreement with empirical equations. (author)

  16. Quantitative analysis of cholesteatoma using high resolution computed tomography

    International Nuclear Information System (INIS)

    Kikuchi, Shigeru; Yamasoba, Tatsuya; Iinuma, Toshitaka.

    1992-01-01

    Seventy-three cases of adult cholesteatoma, including 52 cases of pars flaccida type cholesteatoma and 21 of pars tensa type cholesteatoma, were examined using high resolution computed tomography, in both axial (lateral semicircular canal plane) and coronal sections (cochlear, vestibular and antral plane). These cases were classified into two subtypes according to the presence of extension of cholesteatoma into the antrum. Sixty cases of chronic otitis media with central perforation (COM) were also examined as controls. Various locations of the middle ear cavity were measured in terms of size in comparison with pars flaccida type cholesteatoma, pars tensa type cholesteatoma and COM. The width of the attic was significantly larger in both pars flaccida type and pars tensa type cholesteatoma than in COM. With pars flaccida type cholesteatoma there was a significantly larger distance between the malleus and lateral wall of the attic than with COM. In contrast, the distance between the malleus and medial wall of the attic was significantly larger with pars tensa type cholesteatoma than with COM. With cholesteatoma extending into the antrum, regardless of the type of cholesteatoma, there were significantly larger distances than with COM at the following sites: the width and height of the aditus ad antrum, and the width, height and anterior-posterior diameter of the antrum. However, these distances were not significantly different between cholesteatoma without extension into the antrum and COM. The hitherto demonstrated qualitative impressions of bone destruction in cholesteatoma were quantitatively verified in detail using high resolution computed tomography. (author)

  17. Accelerated high-resolution photoacoustic tomography via compressed sensing

    Science.gov (United States)

    Arridge, Simon; Beard, Paul; Betcke, Marta; Cox, Ben; Huynh, Nam; Lucka, Felix; Ogunlade, Olumide; Zhang, Edward

    2016-12-01

    Current 3D photoacoustic tomography (PAT) systems offer either high image quality or high frame rates but are not able to deliver high spatial and temporal resolution simultaneously, which limits their ability to image dynamic processes in living tissue (4D PAT). A particular example is the planar Fabry-Pérot (FP) photoacoustic scanner, which yields high-resolution 3D images but takes several minutes to sequentially map the incident photoacoustic field on the 2D sensor plane, point-by-point. However, as the spatio-temporal complexity of many absorbing tissue structures is rather low, the data recorded in such a conventional, regularly sampled fashion is often highly redundant. We demonstrate that combining model-based, variational image reconstruction methods using spatial sparsity constraints with the development of novel PAT acquisition systems capable of sub-sampling the acoustic wave field can dramatically increase the acquisition speed while maintaining a good spatial resolution: first, we describe and model two general spatial sub-sampling schemes. Then, we discuss how to implement them using the FP interferometer and demonstrate the potential of these novel compressed sensing PAT devices through simulated data from a realistic numerical phantom and through measured data from a dynamic experimental phantom as well as from in vivo experiments. Our results show that images with good spatial resolution and contrast can be obtained from highly sub-sampled PAT data if variational image reconstruction techniques that describe the tissues structures with suitable sparsity-constraints are used. In particular, we examine the use of total variation (TV) regularization enhanced by Bregman iterations. These novel reconstruction strategies offer new opportunities to dramatically increase the acquisition speed of photoacoustic scanners that employ point-by-point sequential scanning as well as reducing the channel count of parallelized schemes that use detector arrays.

  18. High resolution computed tomography of the post partum pituitary gland

    International Nuclear Information System (INIS)

    Hinshaw, D.B.; Hasso, A.N.; Thompson, J.R.; Davidson, B.J.

    1984-01-01

    Eight volunteer post partum female patients were examined with high resolution computed tomography during the week immediately after delivery. All patients received high dose (40-70 gm) intravenous iodine contrast administration. The scans were examined for pituitary gland height, shape and homogeneity. All of the patients had enlarged glands by the traditional standards (i.e. gland height of 8 mm or greater). The diaphragma sellae in every call bulged upward with a convex domed appearance. The glands were generally inhomogeneous. One gland had a 4 mm focal well defined area of decreased attenuation. Two patients who were studied again months later had glands which had returned to ''normal'' size. The enlarged, upwardly convex pituitary gland appears to be typical and normal for the recently post partum period. (orig.)

  19. High-resolution multimodal clinical multiphoton tomography of skin

    Science.gov (United States)

    König, Karsten

    2011-03-01

    This review focuses on multimodal multiphoton tomography based on near infrared femtosecond lasers. Clinical multiphoton tomographs for 3D high-resolution in vivo imaging have been placed into the market several years ago. The second generation of this Prism-Award winning High-Tech skin imaging tool (MPTflex) was introduced in 2010. The same year, the world's first clinical CARS studies have been performed with a hybrid multimodal multiphoton tomograph. In particular, non-fluorescent lipids and water as well as mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen has been imaged with submicron resolution in patients suffering from psoriasis. Further multimodal approaches include the combination of multiphoton tomographs with low-resolution wide-field systems such as ultrasound, optoacoustical, OCT, and dermoscopy systems. Multiphoton tomographs are currently employed in Australia, Japan, the US, and in several European countries for early diagnosis of skin cancer, optimization of treatment strategies, and cosmetic research including long-term testing of sunscreen nanoparticles as well as anti-aging products.

  20. High resolution computed tomography of the middle ear

    International Nuclear Information System (INIS)

    Ikeda, Katsuhisa; Sakurai, Tokio; Saijo, Shigeru; Kobayashi, Toshimitsu

    1983-01-01

    High resolution computed tomography was performed in 57 cases with various middle ear diseases (chronic otitis media, otitis media with effusion, acute otitis media and atelectasis). Although further improvement in detectability is necessary in order to discriminate each type of the soft tissue lesions, CT is the most useful method currently available in detecting the small structures and soft tissue lesions of the middle ear. In particular, the lesions at the tympanic isthmus and tympanic fold could very clearly be detected only by CT. In acute otitis media, lesions usually started in the attic and spread to the mastoid air cells. In otitis media with effusion, the soft tissue shadow was ovserved in the attic and mastoid air cell. CT is valuable in diagnosis, evaluation of the treatment and prognosis, and analysis of pathophysiology in the middle ear diseases. (author)

  1. Pulmonary leukemic involvement: high-resolution computed tomography evaluation

    International Nuclear Information System (INIS)

    Oliveira, Ana Paola de; Marchiori, Edson; Souza Junior, Arthur Soares

    2004-01-01

    Objective: To evaluate the role of high-resolution computed tomography (HRCT) in patients with leukemia and pulmonary symptoms, to establish the main patterns and to correlate them with the etiology. Materials and Methods: This is a retrospective study of the HRCT of 15 patients with leukemia and pulmonary symptoms. The examinations were performed using a spatial high-resolution protocol and were analyzed by two independent radiologists. Results: The main HRCT patterns found were ground-glass opacity (n=11), consolidation (n=9), airspace nodules (n=3), septal thickening (n=3), tree-in-bud pattern (n=3), and pleural effusion (n=3). Pulmonary infection was the most common finding seen in 12 patients: bacterial pneumonia (n=6), fungal infection (n = 4), pulmonary tuberculosis (n=1) and viral infection (n=1). Leukemic pleural infiltration (n=1), lymphoma (n=1) and pulmonary hemorrhage (n=1) were detected in the other three patients. Conclusion: HRCT is an important tool that may suggest the cause of lung involvement, its extension and in some cases to guide invasive procedures in patients with leukemia. (author)

  2. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  3. High resolution functional photoacoustic tomography of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xiaoqi; Yao, Lei; Xi, Lei; Jiang, Huabei, E-mail: hjiang@bme.ufl.edu [Department of Biomedical Engineering, University of Florida, Gainesville, Florida 32611 (United States); Heldermon, Coy D. [Department of Medicine, University of Florida, Gainesville, Florida 32611 (United States)

    2015-09-15

    Purpose: To evaluate the feasibility of functional photoacoustic tomography (fPAT) for high resolution detection and characterization of breast cancer and to demonstrate for the first time quantitative hemoglobin concentration and oxygen saturation images of breasts that were formed with model-based reconstruction of tomographic photoacoustic data. Methods: The study was HIPAA compliant and was approved by the university institutional review board. Written informed consents were obtained from all the participants. Ten cases, including six cancer and four healthy (mean age = 50 yr; age range = 41–66 yr), were examined. Functional images of breast tissue including absolute total hemoglobin concentration (Hb{sub T}) and oxygen saturation (StO{sub 2}%) were obtained by fPAT and cross validated with magnetic resonance imaging (MRI) readings and/or histopathology. Results: Hb{sub T} and StO{sub 2}% maps from all six pathology-confirmed cancer cases (60%) show clear detection of tumor, while MR images indicate clear detection of tumor for five of six cancer cases; one small tumor was read as near-complete-resolution by MRI. The average Hb{sub T} and StO{sub 2}% value of suspicious lesion area for the cancer cases was 61.6 ± 18.9 μM/l and 67.5% ± 5.2% compared to 25.6 ± 7.4 μM/l and 65.2% ± 3.8% for background normal tissue. Conclusions: fPAT has the potential to be a significant add-on in breast cancer detection and characterization as it provides submillimeter resolution functional images of breast lesions.

  4. Optimised performance of industrial high resolution computerised tomography

    International Nuclear Information System (INIS)

    Maangaard, M.

    2000-01-01

    -sensitivity/noise, density-sensitivity/noise, and mass attenuation-sensitivity/noise. With these measures, a method is presented that finds the optimal equipment settings, where no improvement can be made without worsening at least one other sensitivity/noise ratio. This thesis includes modelling and verification of the sharpness of the CT system in terms of the modulation transfer function, MTF. Together with the limiting perception factor and the maximised SNR the detectability limits for any specific contrasting detail in the centre of a cylindrical sample can be determined. It is also demonstrated that the model can be used to suppress beam hardening when collecting CT-data. When homogeneous samples are imaged, the model can in addition be used to make post-processing corrections for suppressing the beam hardening artefacts. Wavelet-based local tomography has been found to produce images with good accuracy from projection data only from a small region in a sample. This technique is demonstrated on thermal barrier coatings, which contain internal cracks. With optimised equipment settings and geometrical magnification of a region in the sample, wavelet-based local tomography produced high-resolution images of excellent quality. The increased resolution reveals features in the microstructure that cannot be resolved with traditional CT. This technique will be a useful tool for characterisation of the microstructure in advanced materials

  5. Pulmonary high-resolution computed tomography findings in nephropathia epidemica

    Energy Technology Data Exchange (ETDEWEB)

    Paakkala, Antti, E-mail: antti.paakkala@pshp.fi [Medical Imaging Centre, Tampere University Hospital, 33521 Tampere (Finland); Jaervenpaeae, Ritva, E-mail: ritva.jarvenpaa@pshp.fi [Medical Imaging Centre, Tampere University Hospital, 33521 Tampere (Finland); Maekelae, Satu, E-mail: satu.marjo.makela@uta.fi [Department of Internal Medicine, Tampere University Hospital, 33521 Tampere (Finland); Medical School, University of Tampere, 33521 Tampere (Finland); Huhtala, Heini, E-mail: heini.huhtala@uta.fi [School of Public Health, University of Tampere, 33521 Tampere (Finland); Mustonen, Jukka, E-mail: jukka.mustonen@uta.fi [Department of Internal Medicine, Tampere University Hospital, 33521 Tampere (Finland); Medical School, University of Tampere, 33521 Tampere (Finland)

    2012-08-15

    Purpose: To evaluate lung high-resolution computed tomography (HRCT) findings in patients with Puumala hantavirus-induced nephropathia epidemica (NE), and to determine if these findings correspond to chest radiograph findings. Materials and methods: HRCT findings and clinical course were studied in 13 hospital-treated NE patients. Chest radiograph findings were studied in 12 of them. Results: Twelve patients (92%) showed lung parenchymal abnormalities in HRCT, while only 8 had changes in their chest radiography. Atelectasis, pleural effusion, intralobular and interlobular septal thickening were the most common HRCT findings. Ground-glass opacification (GGO) was seen in 4 and hilar and mediastinal lymphadenopathy in 3 patients. Atelectasis and pleural effusion were also mostly seen in chest radiographs, other findings only in HRCT. Conclusion: Almost every NE patient showed lung parenchymal abnormalities in HRCT. The most common findings of lung involvement in NE can be defined as accumulation of pleural fluid and atelectasis and intralobular and interlobular septal thickening, most profusely in the lower parts of the lung. As a novel finding, lymphadenopathy was seen in a minority, probably related to capillary leakage and overall fluid overload. Pleural effusion is not the prominent feature in other viral pneumonias, whereas intralobular and interlobular septal thickening are characteristic of other viral pulmonary infections as well. Lung parenchymal findings in HRCT can thus be taken not to be disease-specific in NE and HRCT is useful only for scientific purposes.

  6. Towards high-resolution positron emission tomography for small volumes

    International Nuclear Information System (INIS)

    McKee, B.T.A.

    1982-01-01

    Some arguments are made regarding the medical usefulness of high spatial resolution in positron imaging, even if limited to small imaged volumes. Then the intrinsic limitations to spatial resolution in positron imaging are discussed. The project to build a small-volume, high resolution animal research prototype (SHARP) positron imaging system is described. The components of the system, particularly the detectors, are presented and brief mention is made of data acquisition and image reconstruction methods. Finally, some preliminary imaging results are presented; a pair of isolated point sources and 18 F in the bones of a rabbit. Although the detector system is not fully completed, these first results indicate that the goals of high sensitivity and high resolution (4 mm) have been realized. (Auth.)

  7. High Resolution Computed Tomography in Asthma 

    Directory of Open Access Journals (Sweden)

    Nabil Maradny

    2012-03-01

    Full Text Available  Objectives: High-resolution computed tomography (HRCT can detect the structural abnormalities in asthma. This study attempts to correlate these abnormalities with clinical and pulmonary function test (PFT data.Methods: Consecutive stable asthma patients attending Mubarak Al Kabeer Hospital, Kuwait, were subjected to HRCT during a six month period from July 2004 to December 2004, after initial evaluation and PFT.Results: Of the 28 cases, sixteen (57.1�20had moderate, 6 (21.4�20had mild and 6 (21.4�20had severe persistent asthma. Thirteen (46.4�20patients had asthma for 1 to 5 years and 12 (42.9�20were having asthma for >10 years. Bronchial wall thickening (57.1� bronchiectasis (28.6� mucoid impaction (17.9� mosaic attenuation (10.7� air trapping (78.6�20and plate like atelectasis (21.4�20were noted. Bronchial wall thickening (p=0.044 and bronchiectasis (p=0.063 were most prevalent in males. Ten (35.7�20patients exhibited mild, 9 (32.1�20had moderate and 3 (10.7�20had severe air trapping. The difference in Hounsfield units between expiratory and inspiratory slices (air trapping when correlated with percent-predicted FEV1 in right upper (r=0.25;p=0.30, left upper (r=0.20; p=0.41, right mid (r=0.15; p=0.53, left mid (r=-0.04; p=0.60, right lower (r=0.04; p=0.86 and left lower zones (r=-0.13; p=0.58 showed no relation. The same when correlated as above with the percent predicted FEF 25-75 did not show any significant association. The presence of air trapping was compared with sex (p=0.640, nationality (p=1.000, disease duration (p=1.000 and severity of symptoms (p=0.581.Conclusion: Abnormal HRCT findings are common in asthma; however, air trapping when present was not related to the duration or severity of the illness or to the FEV1.

  8. Ultra high resolution soft x-ray tomography

    International Nuclear Information System (INIS)

    Haddad, W.S.; Trebes, J.E.; Goodman, D.M.; Lee, H.R.; McNulty, I.; Zalensky, A.O.

    1995-01-01

    Ultra high resolution three dimensional images of a microscopic test object were made with soft x-rays using a scanning transmission x-ray microscope. The test object consisted of two different patterns of gold bars on silicon nitride windows that were separated by ∼5 microm. A series of nine 2-D images of the object were recorded at angles between -50 to +55 degrees with respect to the beam axis. The projections were then combined tomographically to form a 3-D image by means of an algebraic reconstruction technique (ART) algorithm. A transverse resolution of ∼ 1,000 angstrom was observed. Artifacts in the reconstruction limited the overall depth resolution to ∼ 6,000 angstrom, however some features were clearly reconstructed with a depth resolution of ∼ 1,000 angstrom. A specially modified ART algorithm and a constrained conjugate gradient (CCG) code were also developed as improvements over the standard ART algorithm. Both of these methods made significant improvements in the overall depth resolution, bringing it down to ∼ 1,200 angstrom overall. Preliminary projection data sets were also recorded with both dry and re-hydrated human sperm cells over a similar angular range

  9. Ultra high resolution soft x-ray tomography

    International Nuclear Information System (INIS)

    Haddad, W.S.; Trebes, J.E.; Goodman, D.M.

    1995-01-01

    Ultra high resolution three dimensional images of a microscopic test object were made with soft x-rays using a scanning transmission x-ray microscope. The test object consisted of two different patterns of gold bars on silicon nitride windows that were separated by ∼5μm. A series of nine 2-D images of the object were recorded at angles between -50 to +55 degrees with respect to the beam axis. The projections were then combined tomographically to form a 3-D image by means of an algebraic reconstruction technique (ART) algorithm. A transverse resolution of ∼1000 Angstrom was observed. Artifacts in the reconstruction limited the overall depth resolution to ∼6000 Angstrom, however some features were clearly reconstructed with a depth resolution of ∼1000 Angstrom. A specially modified ART algorithm and a constrained conjugate gradient (CCG) code were also developed as improvements over the standard ART algorithm. Both of these methods made significant improvements in the overall depth resolution bringing it down to ∼1200 Angstrom overall. Preliminary projection data sets were also recorded with both dry and re-hydrated human sperm cells over a similar angular range

  10. The clinical impact of high resolution computed tomography in patients with respiratory disease

    International Nuclear Information System (INIS)

    Screaton, Nicholas J.; Tasker, Angela D.; Flower, Christopher D.R.; Miller, Fiona N.A.C.; Patel, Bipen D.; Groves, Ashley; Lomas, David A.

    2011-01-01

    High resolution computed tomography is widely used to investigate patients with suspected diffuse lung disease. Numerous studies have assessed the diagnostic performance of this investigation, but the diagnostic and therapeutic impacts have received little attention. The diagnostic and therapeutic impacts of high resolution computed tomography in routine clinical practice were evaluated prospectively. All 507 referrals for high-resolution computed tomography over 12 months in two centres were included. Requesting clinicians completed questionnaires before and after the investigation detailing clinical indications, working diagnoses, confidence level in each diagnosis, planned investigations and treatments. Three hundred and fifty-four studies on 347 patients had complete data and were available for analysis. Following high-resolution computed tomography, a new leading diagnosis (the diagnosis with the highest confidence level) emerged in 204 (58%) studies; in 166 (47%) studies the new leading diagnosis was not in the original differential diagnosis. Mean confidence in the leading diagnosis increased from 6.7 to 8.5 out of 10 (p < 0.001). The invasiveness of planned investigations increased in 23 (7%) studies and decreased in 124 (35%) studies. The treatment plan was modified after 319 (90%) studies. Thoracic high-resolution computed tomography alters leading diagnosis, increases diagnostic confidence, and frequently changes investigation and management plans. (orig.)

  11. High-resolution computed tomography and histopathological findings in hypersensitivity pneumonitis: a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Pedro Paulo Teixeira e Silva; Moreira, Marise Amaral Reboucas; Silva, Daniela Graner Schuwartz Tannus; Moreira, Maria Auxiliadora do Carmo [Universidade Federal de Goias (UFG), Goiania, GO (Brazil); Gama, Roberta Rodrigues Monteiro da [Hospital do Cancer de Barretos, Barretos, SP (Brazil); Sugita, Denis Masashi, E-mail: pedroptstorres@yahoo.com.br [Anapolis Unievangelica, Anapolis, GO (Brazil)

    2016-03-15

    Hypersensitivity pneumonitis is a diffuse interstitial and granulomatous lung disease caused by the inhalation of any one of a number of antigens. The objective of this study was to illustrate the spectrum of abnormalities in high-resolution computed tomography and histopathological findings related to hypersensitivity pneumonitis. We retrospectively evaluated patients who had been diagnosed with hypersensitivity pneumonitis (on the basis of clinical-radiological or clinical-radiological-pathological correlations) and had undergone lung biopsy. Hypersensitivity pneumonitis is clinically divided into acute, subacute, and chronic forms; high-resolution computed tomography findings correlate with the time of exposure; and the two occasionally overlap. In the subacute form, centrilobular micronodules, ground glass opacities, and air trapping are characteristic high-resolution computed tomography findings, whereas histopathology shows lymphocytic inflammatory infiltrates, bronchiolitis, variable degrees of organizing pneumonia, and giant cells. In the chronic form, high-resolution computed tomography shows traction bronchiectasis, honeycombing, and lung fibrosis, the last also being seen in the biopsy sample. A definitive diagnosis of hypersensitivity pneumonitis can be made only through a multidisciplinary approach, by correlating clinical findings, exposure history, high-resolution computed tomography findings, and lung biopsy findings. (author)

  12. Physical fundamentals of high-resolution computerized tomography

    International Nuclear Information System (INIS)

    Kalender, W.A.; Suess, C.

    1985-01-01

    A model is demonstrated allowing on assessment of the influence of various factors on local or spatial resolution. Separate establishment of data collection, picture reconstruction and representation is important. Different aspects depending on device type obtain when collecting data. When assessing and developing device types further, attention should be given to the weakest chain links which determine local resolution. However, we should never forget that local resolution is but one parameter for describing picture quality. Resolution of low contrasts and freedom from artifacts are at least as important parameters for the assessment of the total CT system. (orig.) [de

  13. Pneumocystis carinii pneumonia in acquired immunodeficiency syndrome - correlation of high-resolution computed tomography and anatomopathology

    International Nuclear Information System (INIS)

    Marchiori, Edson; Moreira, Luiza Beatriz; Capone, Domenico; Moraes, Heleno Pinto de; Pereira, Cyntia Inez Guedes Soares

    2001-01-01

    We present the main findings observed on the high-resolution computed tomography examinations of 15 patients with acquired immunodeficiency syndrome and Pneumocystis carinii pneumonia. The high-resolution computed tomography and autopsy findings of 5 patients were also compared. The most frequently observed high-resolution computed tomography patterns were ground-glass attenuation, consolidation areas, crazy-paving pattern and cysts. Nodules and intralobular reticulation were less frequently observed. Ground-glass attenuation and consolidation areas corresponded to alveolar filling with inflammatory exudate. Thickening of the interlobular septa was due to cell infiltration and edema. One patient presented interlobular reticulation, and the pathology study revealed alveolar septa thickening due to cell infiltration and fibrosis. Nodules observed in one of the patients corresponded to a patchy intra alveolar accumulation of microorganisms and inflammatory cells forming a 'granulomatous' pattern. (author)

  14. High-resolution coded-aperture design for compressive X-ray tomography using low resolution detectors

    Science.gov (United States)

    Mojica, Edson; Pertuz, Said; Arguello, Henry

    2017-12-01

    One of the main challenges in Computed Tomography (CT) is obtaining accurate reconstructions of the imaged object while keeping a low radiation dose in the acquisition process. In order to solve this problem, several researchers have proposed the use of compressed sensing for reducing the amount of measurements required to perform CT. This paper tackles the problem of designing high-resolution coded apertures for compressed sensing computed tomography. In contrast to previous approaches, we aim at designing apertures to be used with low-resolution detectors in order to achieve super-resolution. The proposed method iteratively improves random coded apertures using a gradient descent algorithm subject to constraints in the coherence and homogeneity of the compressive sensing matrix induced by the coded aperture. Experiments with different test sets show consistent results for different transmittances, number of shots and super-resolution factors.

  15. Refinement procedure for the image alignment in high-resolution electron tomography

    International Nuclear Information System (INIS)

    Houben, L.; Bar Sadan, M.

    2011-01-01

    High-resolution electron tomography from a tilt series of transmission electron microscopy images requires an accurate image alignment procedure in order to maximise the resolution of the tomogram. This is the case in particular for ultra-high resolution where even very small misalignments between individual images can dramatically reduce the fidelity of the resultant reconstruction. A tomographic-reconstruction based and marker-free method is proposed, which uses an iterative optimisation of the tomogram resolution. The method utilises a search algorithm that maximises the contrast in tomogram sub-volumes. Unlike conventional cross-correlation analysis it provides the required correlation over a large tilt angle separation and guarantees a consistent alignment of images for the full range of object tilt angles. An assessment based on experimental reconstructions shows that the marker-free procedure is competitive to the reference of marker-based procedures at lower resolution and yields sub-pixel accuracy even for simulated high-resolution data. -- Highlights: → Alignment procedure for electron tomography based on iterative tomogram contrast optimisation. → Marker-free, independent of object, little user interaction. → Accuracy competitive with fiducial marker methods and suited for high-resolution tomography.

  16. High-resolution PET [Positron Emission Tomography] for Medical Science Studies

    Science.gov (United States)

    Budinger, T. F.; Derenzo, S. E.; Huesman, R. H.; Jagust, W. J.; Valk, P. E.

    1989-09-01

    One of the unexpected fruits of basic physics research and the computer revolution is the noninvasive imaging power available to today's physician. Technologies that were strictly the province of research scientists only a decade or two ago now serve as the foundations for such standard diagnostic tools as x-ray computer tomography (CT), magnetic resonance imaging (MRI), magnetic resonance spectroscopy (MRS), ultrasound, single photon emission computed tomography (SPECT), and positron emission tomography (PET). Furthermore, prompted by the needs of both the practicing physician and the clinical researcher, efforts to improve these technologies continue. This booklet endeavors to describe the advantages of achieving high resolution in PET imaging.

  17. A high time and spatial resolution MRPC designed for muon tomography

    Science.gov (United States)

    Shi, L.; Wang, Y.; Huang, X.; Wang, X.; Zhu, W.; Li, Y.; Cheng, J.

    2014-12-01

    A prototype of cosmic muon scattering tomography system has been set up in Tsinghua University in Beijing. Multi-gap Resistive Plate Chamber (MRPC) is used in the system to get the muon tracks. Compared with other detectors, MRPC can not only provide the track but also the Time of Flight (ToF) between two detectors which can estimate the energy of particles. To get a more accurate track and higher efficiency of the tomography system, a new type of high time and two-dimensional spatial resolution MRPC has been developed. A series of experiments have been done to measure the efficiency, time resolution and spatial resolution. The results show that the efficiency can reach 95% and its time resolution is around 65 ps. The cluster size is around 4 and the spatial resolution can reach 200 μ m.

  18. High resolution computed tomography of chronic otitis media

    International Nuclear Information System (INIS)

    Shirahata, Yuichi; Tachibana, Toshiro; Fukami, Masaya; Onishi, Toshiro; Doi, Osamu

    1986-01-01

    Seventy six patients with chronic otitis media were examined by CT. Using 3 dried skulls, the epitympanum was impacted with a piece of paraffin containing of 2 % iodine, and studied with CT-scan (Toshiba 60A-30) to clarify whether or not the paraffin could produce a soft tissue density on CT which was similar to that of cholesteatoma in the middle ear. The results showed that computed tomography was excellent in demonstrating a soft tissue mass in the middle ear with inflammatory disease. When the middle ear infection with granulation tissue or cholesteatoma existed, the resulting soft tissue mass was indistinguishable. CT scanning was useful for accurate determination of location of bone destruction in the middle ear as well as of the ossicles. (author)

  19. High-resolution computed tomography scan of lumbosacral spine

    International Nuclear Information System (INIS)

    Lifson, A.; Heithoff, K.B.; Burton, C.V.; Ray, C.D.

    1981-01-01

    A GE 8800 computed tomography (CT) scanner was used in over 4,000 cases of acute and chronic low back pain. Practically unlimited potentials of the study were clearly demonstrated in the diagnosis of such conditions as central and lateral spinal stenosis, overgrowth of fusions, disk herniation and free extrusion. Nonenhanced CT scanning is capable of clear visualization of soft-tissue structures: nerve roots and ganglia, epidural fat, epidural fibrous tissue, and epidural veins. CT scanning has become a primary diagnostic modality in the Low Back Clinic at our institute, replacing myelography in the majority of cases. Enhancement of the image with metrizamide was found to be of limited diagnostic value in lumbar degenerative disk disease. However, the utilization of a radiopaque material is indicated in selected circumstances. (Auth.)

  20. High-resolution retinal imaging using adaptive optics and Fourier-domain optical coherence tomography

    Science.gov (United States)

    Olivier, Scot S.; Werner, John S.; Zawadzki, Robert J.; Laut, Sophie P.; Jones, Steven M.

    2010-09-07

    This invention permits retinal images to be acquired at high speed and with unprecedented resolution in three dimensions (4.times.4.times.6 .mu.m). The instrument achieves high lateral resolution by using adaptive optics to correct optical aberrations of the human eye in real time. High axial resolution and high speed are made possible by the use of Fourier-domain optical coherence tomography. Using this system, we have demonstrated the ability to image microscopic blood vessels and the cone photoreceptor mosaic.

  1. Forward transformation for high resolution eddy current tomography using whitney elements

    International Nuclear Information System (INIS)

    Szewczyk, R.; Salach, J.; Nowicki, M.; Ruokolainen, J.; Raback, P.

    2014-01-01

    Tomographic methods are intensively developed field of non-destructive testing. The main advantage of this type of NDT method is 3D information concerning the shape of the discontinuities in investigated material. On the other hand, the most common tomography method utilizing X-rays creates the significant risks typical to X-ray technique. As a result, Xray tomography is difficult to use in industry. Introduced to the industry in 2007, the eddy current tomography is safe and cost effective. However, in opposite to X-ray tomography, eddy current tomography requires sophisticated and time consuming inverse transformation creating 2D or 3D view of discontinuities. For this reason solutions presented previously are focused on 2D inverse transformation and exhibit limited resolution. For eddy current tomography, the forward tomographic transformation is most important, which is the base of inverse transformation. This paper presents the novel, fast and cost-effective solution utilizing Whitney elements method for such forward transformation. As a result, new possibilities of development in the area of high resolution 3D eddy current tomography are created. (authors)

  2. 'High resolution' computerized tomography in spinal narrow and spinal column diagnosis

    International Nuclear Information System (INIS)

    Koester, O.

    1985-01-01

    Bearing in mind that direct comparison is lacking, high resolution computerized tomography in spinal column diagnosis can be said to supply considerably increased information when dealing with the issues of a cervical prolapse and bony changes of any origin. Its advantages appear to be reduced when assessing lumbar prolapse, intraspinal masses and paravertebral soft-tissue processes. (orig.) [de

  3. Diagnostic Yield of Transbronchial Biopsy in Comparison to High Resolution Computerized Tomography in Sarcoidosis Cases

    Science.gov (United States)

    Akten, H Serpil; Kilic, Hatice; Celik, Bulent; Erbas, Gonca; Isikdogan, Zeynep; Turktas, Haluk; Kokturk, Nurdan

    2018-04-25

    This study aimed to evaluate the diagnostic yield of fiberoptic bronchoscopic (FOB) transbronchial biopsy and its relation with quantitative findings of high resolution computerized tomography (HRCT). A total of 83 patients, 19 males and 64 females with a mean age of 45.1 years diagnosed with sarcoidosis with complete records of high resolution computerized tomography were retrospectively recruited during the time period from Feb 2005 to Jan 2015. High resolution computerized tomography scans were retrospectively assessed in random order by an experienced observer without knowledge of the bronchoscopic results or lung function tests. According to the radiological staging with HRCT, 2.4% of the patients (n=2) were stage 0, 19.3% (n=16) were stage 1, 72.3% (n=60) were stage 2 and 6.0% (n=5) were stage 3. This study showed that transbronchial lung biopsy showed positive results in 39.7% of the stage I or II sarcoidosis patients who were diagnosed by bronchoscopy. Different high resolution computerized tomography patterns and different scores of involvement did make a difference in the diagnostic accuracy of transbronchial biopsy (p=0.007). Creative Commons Attribution License

  4. High-resolution computed tomography findings in pulmonary Langerhans cell histiocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Rosana Souza [Universidade Federal do Rio de Janeiro (HUCFF/UFRJ), RJ (Brazil). Hospital Universitario Clementino Fraga Filho. Unit of Radiology; Capone, Domenico; Ferreira Neto, Armando Leao [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil)

    2011-07-15

    Objective: The present study was aimed at characterizing main lung changes observed in pulmonary Langerhans cell histiocytosis by means of high-resolution computed tomography. Materials and Methods: High-resolution computed tomography findings in eight patients with proven disease diagnosed by open lung biopsy, immunohistochemistry studies and/or extrapulmonary manifestations were retrospectively evaluated. Results: Small rounded, thin-walled cystic lesions were observed in the lung of all the patients. Nodules with predominantly peripheral distribution over the lung parenchyma were observed in 75% of the patients. The lesions were diffusely distributed, predominantly in the upper and middle lung fields in all of the cases, but involvement of costophrenic angles was observed in 25% of the patients. Conclusion: Comparative analysis of high-resolution computed tomography and chest radiography findings demonstrated that thinwalled cysts and small nodules cannot be satisfactorily evaluated by conventional radiography. Because of its capacity to detect and characterize lung cysts and nodules, high-resolution computed tomography increases the probability of diagnosing pulmonary Langerhans cell histiocytosis. (author)

  5. Analyzing 3D xylem networks in Vitis vinifera using High Resolution Computed Tomography (HRCT)

    Science.gov (United States)

    Recent developments in High Resolution Computed Tomography (HRCT) have made it possible to visualize three dimensional (3D) xylem networks without time consuming, labor intensive physical sectioning. Here we describe a new method to visualize complex vessel networks in plants and produce a quantitat...

  6. Pulmonary malaria: high-resolution computed tomography findings - a case report

    International Nuclear Information System (INIS)

    Rodrigues, Rosana; Souza, Daniel Andrade Tinoco de; Marchiori, Edson

    2004-01-01

    We report the case of a 38-year-old man with pulmonary malaria. High-resolution computed tomography showed thickening of the peribronchovascular interstitium and interlobular septa, areas of consolidation and ground glass attenuation and bilateral pleural effusion suggesting pulmonary edema. The patient recovered well after receiving specific treatment and was discharged after 11 days of hospitalization. (author)

  7. Clinical use of pulmonary function tests and high-resolution tomography in interstitial lung diseases

    International Nuclear Information System (INIS)

    Garcia C, Clara P; Mejia M, Luis F

    2010-01-01

    Diagnosis of interstitial lung diseases is generally arrived at by clinical history, physical examination, and radiologic images, especially high-resolution CT-scanning. It is important to note that, while these diseases have different clinical and histological characteristics, they share a basic pattern of abnormal lung function. With regard to high-resolution tomography, the characteristics of these diseases are similar, although there are specific differences that can be helpful for correct diagnosis. These diseases have severe consequences on respiratory gas exchange. These alterations, combined with other abnormalities of lung function, cause the signs and symptoms and have an impact on quality of life. The use of physiologic parameters is not only helpful for diagnosis, but can also assess severity, help to define the consequences of treatment, and aid in the follow-up. Although some pulmonary function tests can remain completely normal with severe radiographic findings, 10% of patients have impaired lung function before radiologic changes. High-resolution tomography is an essential imaging tool for the study of these patients. This is true not only for diagnosis, but also with regard to clinical parameters and follow-up. Its prognostic use is continually gaining importance. In this article we assess the clinical use of pulmonary function tests and high-resolution tomography in interstitial lung diseases.

  8. Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner

    OpenAIRE

    Kakinuma, Ryutaro; Moriyama, Noriyuki; Muramatsu, Yukio; Gomi, Shiho; Suzuki, Masahiro; Nagasawa, Hirobumi; Kusumoto, Masahiko; Aso, Tomohiko; Muramatsu, Yoshihisa; Tsuchida, Takaaki; Tsuta, Koji; Maeshima, Akiko Miyagi; Tochigi, Naobumi; Watanabe, Shun-ichi; Sugihara, Naoki

    2015-01-01

    Purpose: The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. Materials and Methods: This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm × 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm × 16 or 0.5 mm × 64 detector-row CT scanner operating at 150 mAs. Images fr...

  9. Lipoid pneumonia in adults: findings on high-resolution computed tomography

    International Nuclear Information System (INIS)

    Marchiori, Edson; Escuissato, Dante L.; Souza Junior, Arthur Soares; Araujo Neto, Cesar; Nobre, Luiz Felipe; Irion, Klaus L.; Rodrigues, Rosana; Mancano, Alexandre Dias; Capone, Domenico; Fialho, Suzane Mansur; Souza, Carolina Althoff

    2007-01-01

    Objective: The present study was aimed at describing the findings on high-resolution computed tomography in patients with exogenous lipoid pneumonia secondary to mineral oil aspiration. Materials and methods: Eight adult patients - four men and four women - with mean age of 69.4 years were studied. All of the patients were users of mineral oil for treating intestinal constipation. High-resolution computed tomography studies of these patients were blindly evaluated by two radiologists. Results: Air-space consolidation with areas of fat density and crazy paving pattern were the most frequent findings. The lesions were bilateral in six cases and unilateral in two. Conclusion: Air-space consolidation with areas of fat density, associated with a clinical history of mineral oil ingestion virtually indicates a diagnosis of exogenous lipoid pneumonia. (author)

  10. Lipoid pneumonia in adults: findings on high-resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. of Radiology]. E-mail: edmarchiori@gmail.com; Zanetti, Glaucia [Faculdade de Medicina de Petropolis, RJ (Brazil); Escuissato, Dante L. [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil); Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil); Araujo Neto, Cesar [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil); Nobre, Luiz Felipe [Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil); Irion, Klaus L. [The Cardiothoracic Centre NHS Trust, Liverpool (United Kingdom); Rodrigues, Rosana [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Hospital Universitario Clementino Fraga Filho (HUCFF); Mancano, Alexandre Dias [Hospital Regional de Taguatinga, Brasilia, DF (Brazil); Capone, Domenico [Universidade Estadual do Rio de Janeiro (UERJ), RJ (Brazil); Fialho, Suzane Mansur [Centro Nuclear da Guanabara, Rio de Janeiro, RJ (Brazil); Souza, Carolina Althoff [University of Ottawa (Canada)

    2007-09-15

    Objective: The present study was aimed at describing the findings on high-resolution computed tomography in patients with exogenous lipoid pneumonia secondary to mineral oil aspiration. Materials and methods: Eight adult patients - four men and four women - with mean age of 69.4 years were studied. All of the patients were users of mineral oil for treating intestinal constipation. High-resolution computed tomography studies of these patients were blindly evaluated by two radiologists. Results: Air-space consolidation with areas of fat density and crazy paving pattern were the most frequent findings. The lesions were bilateral in six cases and unilateral in two. Conclusion: Air-space consolidation with areas of fat density, associated with a clinical history of mineral oil ingestion virtually indicates a diagnosis of exogenous lipoid pneumonia. (author)

  11. High-resolution photoacoustic tomography of resting-state functional connectivity in the mouse brain

    OpenAIRE

    Nasiriavanaki, Mohammadreza; Xia, Jun; Wan, Hanlin; Bauer, Adam Quentin; Culver, Joseph P.; Wang, Lihong V.

    2013-01-01

    The increasing use of mouse models for human brain disease studies presents an emerging need for a new functional imaging modality. Using optical excitation and acoustic detection, we developed a functional connectivity photoacoustic tomography system, which allows noninvasive imaging of resting-state functional connectivity in the mouse brain, with a large field of view and a high spatial resolution. Bilateral correlations were observed in eight functional regions, including the olfactory bu...

  12. High-resolution computed tomography of the lungs: the borderlands of normality

    International Nuclear Information System (INIS)

    Dalal, P.U.; Hansell, D.M.

    2006-01-01

    High-resolution computed tomography (HRCT) is now widely used in the assessment of airways and diffuse lung disease. Considerable literature on pathologic correlation has increased the understanding of the signs of disease seen on HRCT. However, neither the significance of subtle individual signs nor the spectrum of HRCT appearances in healthy lungs is well documented. HRCT signs that cause diagnostic uncertainty and the spectrum of findings that exist between definite normality and definite abnormality are discussed. (orig.)

  13. Noninvasive Characterization of Indeterminate Pulmonary Nodules Detected on Chest High-Resolution Computed Tomography

    Science.gov (United States)

    2017-10-01

    Chest High- Resolution Computed Tomography 5b. GRANT NUMBER W81XWH-15-1-0110 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Fabien Maldonado 5d. PROJECT...Selection of cancer cases and controls, flowcharts : Screen-detected lung cancers (N=649) Adenocarcinomas (N=353) Squamous cell carcinomas (N=136...during the process, and I hope everyone has a nice weekend! Best, Liz …… Elizabeth S. Moses, Ph.D. | Scientific Program Manager, DECAMP Boston

  14. Pulmonary complications of crack cocaine use: high-resolution computed tomography of the chest

    International Nuclear Information System (INIS)

    Mancano, Alexandre

    2008-01-01

    Here, we report high-resolution computed tomography (HRCT) findings in a patient who developed sudden hemoptysis, dyspnea and chest pain after smoking crack cocaine. Chest X-rays showed consolidations, primarily in the upper lobes, and HRCT scans showed ground glass attenuation opacities, consolidations and air-space nodules. A follow-up CT, after drug use discontinuation and administration of corticosteroids, showed partial resolution of pulmonary lesions and the appearance of cavitations. Clinical, imaging and laboratory findings led to a diagnosis of 'crack lung'. (author)

  15. Development of sealed sample containers and high resolution micro-tomography

    Energy Technology Data Exchange (ETDEWEB)

    Uesugi, Kentaro, E-mail: ueken@spring8.or.jp; Takeuchi, Akihisa; Suzuki, Yoshio [Japan synchrotron radiation research institute, JASRI/SPring-8 Kouto 1-1-1, Sayo, Hyogo 679-5198 Japan (Japan); Uesugi, Masayuki [Japan Aerospace Exploration Agency (ISAS/JAXA), Sagamihara, Kanagawa 252-5210 (Japan); Hamada, Hiroshi [NTT Advanced technology Corporation, Atsugi, Kanagawa 243-0124 (Japan)

    2016-01-28

    A sample container and a high resolution micro-tomography system have been developed at BL47XU at SPring-8. The container is made of a SiN membrane in a shape of truncated pyramid, which makes it possible to exclude oxygen and moisture in the air. The sample rotation stage for tomography is set downward to keep the sample in the container without any glue. The spatial resolution and field of view are 300 nm and 110 μm using a Fresnel zone plate objective with an outermost zone width of 100 nm at 8 keV, respectively. The scan time is about 20 minutes for 1800 projections. A 3-D image of an asteroid particle was successfully obtained without adhesive and contamination.

  16. Refinement procedure for the image alignment in high-resolution electron tomography.

    Science.gov (United States)

    Houben, L; Bar Sadan, M

    2011-01-01

    High-resolution electron tomography from a tilt series of transmission electron microscopy images requires an accurate image alignment procedure in order to maximise the resolution of the tomogram. This is the case in particular for ultra-high resolution where even very small misalignments between individual images can dramatically reduce the fidelity of the resultant reconstruction. A tomographic-reconstruction based and marker-free method is proposed, which uses an iterative optimisation of the tomogram resolution. The method utilises a search algorithm that maximises the contrast in tomogram sub-volumes. Unlike conventional cross-correlation analysis it provides the required correlation over a large tilt angle separation and guarantees a consistent alignment of images for the full range of object tilt angles. An assessment based on experimental reconstructions shows that the marker-free procedure is competitive to the reference of marker-based procedures at lower resolution and yields sub-pixel accuracy even for simulated high-resolution data. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Bronchial asthma: correlation of high resolution computerized tomography findings with clinical data

    International Nuclear Information System (INIS)

    Mogami, Roberto; Marchiori, Edson; Kirk, Kennedy; Capone, Domenico; Daltro, Pedro

    1999-01-01

    In this work we did a sectional study of 31 asthmatic patients with several levels of disease severity, which were submitted to high resolution computed tomography of the thorax and spirometry, between the months of July, 1995 and August, 1997. The tomographic findings were correlated with the clinical classification of the patients and the most frequent tomographic findings were bronchial wall thickening, bronchial dilatation, air trapping, centrilobular opacities, cicatricial linear shadows, mucoid impaction, emphysema and atelectasis. In asthmatic patients of long duration we observed small airway disease and irreversible lesions as the predominant findings. In smoking patients there was no high frequency of emphysema. (author)

  18. Computerized tomography using high resolution X-ray imaging system with a microfocus source

    International Nuclear Information System (INIS)

    Zaprazny, Z.; Korytar, D.; Konopka, P.; Ac, V.; Bielecki, J.

    2011-01-01

    In recent years there is an effort to image an internal structure of an object by using not only conventional 2D X-ray radiography but also using high resolution 3D tomography which is based on reconstruction of multiple 2D projections at various angular positions of the object. We have previously reported [1] the development and basic parameters of a high resolution x-ray imaging system with a microfocus source. We report the recent progress using this high resolution X-ray laboratory system in this work. These first findings show that our system is particularly suitable for light weight and nonmetallic objects such as biological objects, plastics, wood, paper, etc. where phase contrast helps to increase the visibility of the finest structures of the object. Phase-contrast X-ray Computerized Tomography is of our special interest because it is an emerging imaging technique that can be implemented at third generation synchrotron radiation sources and also in laboratory conditions using a microfocus X-ray tube or beam conditioning optics. (authors)

  19. High-resolution photoacoustic tomography of resting-state functional connectivity in the mouse brain

    Science.gov (United States)

    Nasiriavanaki, Mohammadreza; Xia, Jun; Wan, Hanlin; Bauer, Adam Quentin; Culver, Joseph P.; Wang, Lihong V.

    2014-01-01

    The increasing use of mouse models for human brain disease studies presents an emerging need for a new functional imaging modality. Using optical excitation and acoustic detection, we developed a functional connectivity photoacoustic tomography system, which allows noninvasive imaging of resting-state functional connectivity in the mouse brain, with a large field of view and a high spatial resolution. Bilateral correlations were observed in eight functional regions, including the olfactory bulb, limbic, parietal, somatosensory, retrosplenial, visual, motor, and temporal regions, as well as in several subregions. The borders and locations of these regions agreed well with the Paxinos mouse brain atlas. By subjecting the mouse to alternating hyperoxic and hypoxic conditions, strong and weak functional connectivities were observed, respectively. In addition to connectivity images, vascular images were simultaneously acquired. These studies show that functional connectivity photoacoustic tomography is a promising, noninvasive technique for functional imaging of the mouse brain. PMID:24367107

  20. A study with high resolution computed tomography of bone destruction in cholesteatoma

    International Nuclear Information System (INIS)

    Kikuchi, Shigeru; Yamaso, Tatsuya; Higo, Ryusaburo; Senba, Tetsuo; Iinuma, Yoshitaka.

    1992-01-01

    The modes and incidences of bone destruction in the middle ear cholesteatoma were evaluated by high resolution computed tomography, comparing with chronic otitis media with central perforation (COM) as control. The head of the malleus, the body and long process of the incus were more markedly destroyed in cholesteatoma than in COM with statistical significance. With the further extension of cholesteatoma into the antrum, the tegmen of the aditus ad antrum, the lateral semicircular canal, the handle of the malleus and the Korner's septum were involved in bone destruction. (author)

  1. Tracking Solid Oxide Cell Microstructure Evolution by High Resolution 3D Nano-Tomography

    DEFF Research Database (Denmark)

    De Angelis, Salvatore

    . The degradation processes are mainly attributed to morphological changes occurring within the electrodes microstructure. Therefore, precise tracking of 3D microstructural evolution during operation is considered crucial to understanding the complex relationship between microstructure and performance. In this work......, X-ray ptychographic tomography is applied to SOC materials, demonstrating unprecedented spatial resolution and data quality. The eect of a complete redox cycle on the same Ni-YSZ microstructure is visualized ex-situ in 3D, showing major rearrangement of the nickel network after reduction......, the formation of cracks in the YSZ, and void formation in nickel oxide after oxidation. Capitalizing on the high resolution of ptychography, the eect of nickel coarsening on the Ni-YSZ microstructure evolution is studied ex-situ in three dimensions, while the sample is repeatedly scanned and treated at high...

  2. Developmental approach towards high resolution optical coherence tomography for glaucoma diagnostics

    Science.gov (United States)

    Kemper, Björn; Ketelhut, Steffi; Heiduschka, Peter; Thorn, Marie; Larsen, Michael; Schnekenburger, Jürgen

    2018-02-01

    Glaucoma is caused by a pathological rise in the intraocular pressure, which results in a progressive loss of vision by a damage to retinal cells and the optical nerve head. Early detection of pressure-induced damage is thus essential for the reduction of eye pressure and to prevent severe incapacity or blindness. Within the new European Project GALAHAD (Glaucoma Advanced, Label free High Resolution Automated OCT Diagnostics), we will develop a new low-cost and high-resolution OCT system for the early detection of glaucoma. The device is designed to improve diagnosis based on a new system of optical coherence tomography. Although OCT systems are at present available in ophthalmology centres, high-resolution devices are extremely expensive. The novelty of the new Galahad system is its super wideband light source to achieve high image resolution at a reasonable cost. Proof of concept experiments with cell and tissue Glaucoma test standards and animal models are planned for the test of the new optical components and new algorithms performance for the identification of Glaucoma associated cell and tissue structures. The intense training of the software systems with various samples should result in a increased sensitivity and specificity of the OCT software system.

  3. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brun, E., E-mail: emmanuel.brun@esrf.fr [European Synchrotron Radiation Facility (ESRF), Grenoble 380000, France and Department of Physics, Ludwig-Maximilians University, Garching 85748 (Germany); Grandl, S.; Sztrókay-Gaul, A.; Gasilov, S. [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Barbone, G. [Department of Physics, Harvard University, Cambridge, Massachusetts 02138 (United States); Mittone, A.; Coan, P. [Department of Physics, Ludwig-Maximilians University, Garching 85748, Germany and Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Bravin, A. [European Synchrotron Radiation Facility (ESRF), Grenoble 380000 (France)

    2014-11-01

    Purpose: Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. Methods: The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure’s possible applications. Results: A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. Conclusions: The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  4. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography.

    Science.gov (United States)

    Brun, E; Grandl, S; Sztrókay-Gaul, A; Barbone, G; Mittone, A; Gasilov, S; Bravin, A; Coan, P

    2014-11-01

    Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure's possible applications. A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  5. Study on a high resolution positron emission tomography scanner for brain study

    International Nuclear Information System (INIS)

    Nohara, N.; Tomitani, T.; Yamamoto, M.; Murayama, H.; Tanaka, E.

    1990-01-01

    The spatial resolution of positron emission tomography (PET) scanners is usually limited by the finite size of crystals such as bismuth germanate (BGO). To attain high resolution as well as high sensitivity, it is essential to use a large number of small BGO crystals arranged in close-packing on circular rings. In developing high resolution PET scanners, however, there are two physical factors limiting the spatial resolution. One is the finite range of positrons before annihilation and the other the deviation from 180 degrees of annihilation photons. The effect of the factors on the spatial resolution has been evaluated for positron-emitting sources as a function of detector ring radius. A high resolution PET scanner has been developed for brain study, aiming to have spatial resolutions as high as less than 4-mm FWHM in tomographic plane and less than 6-mm FWHM in axial direction at the detector ring center. For the goal of the high resolutions a multi-segment type of photomultiplier tubes has been specially designed and developed, which allows one tube to be directly coupled by four BGO crystals. The scanner consists of five detector rings of 47-cm in diameter, using all 1200 BGO crystals each measuring 5 mm x 12 mm x 30 mm. The scanner provides simultaneous 9 images by combination of in-plane and cross-plane, offering a 24-cm dia. x7.4-cm field-of-view. Physical performance of the scanner was investigated. At the ring center, the spatial resolution in the tomographic plane was measured to be 3.5-mm FWHM. The axial resolution was measured to be 5.7-mm FWHM for in-plane and 5.3-mm FWHM for cross-plane. Sensitivity for a 20-cm dia. uniform source was measured to be 9.5 kcps/μCi/ml for in-plane and 15.3 kcps/μCi/ml for cross-plane. (J.P.N.)

  6. Functional high-resolution computed tomography of pulmonary vascular and airway reactions

    International Nuclear Information System (INIS)

    Herold, C.J.; Johns Hopkins Medical Institutions, Baltimore, MD; Brown, R.H.; Johns Hopkins Medical Institutions, Baltimore, MD; Johns Hopkins Medical Institutions, Baltimore, MD; Wetzel, R.C.; Herold, S.M.; Zeerhouni, E.A.

    1993-01-01

    We describe the use of high-resolution computed tomography (HRCT) for assessment of the function of pulmonary vessels and airways. With its excellent spatial resolution, HRCT is able to demonstrate pulmonary structures as small as 300 μm and can be used to monitor changes following various stimuli. HRCT also provides information about structures smaller than 300 μm through measurement of parenchymal background density. To date, sequential, spiral and ultrafast HRCT techniques have been used in a variety of challenges to gather information about the anatomical correlates of traditional physiological measurements, thus making anatomical-physiological correlation possible. HRCT of bronchial reactivity can demonstrate the location and time course of aerosol-induced broncho-constriction and may show changes not apparent on spirometry. HRCT of the pulmonary vascular system visualized adaptations of vessels during hypoxia and intravascular volume loading and elucidates cardiorespiratory interactions. Experimental studies provide a basis for potential clinical applications of this method. (orig.) [de

  7. Ultra-high resolution optical coherence tomography for encapsulation quality inspection

    KAUST Repository

    Czajkowski, Jakub

    2011-08-28

    We present the application of ultra-high resolution optical coherence tomography (UHR-OCT) in evaluation of thin, protective films used in printed electronics. Two types of sample were investigated: microscopy glass and organic field effect transistor (OFET) structure. Samples were coated with thin (1-3 μm) layer of parylene C polymer. Measurements were done using experimental UHR-OCT device based on a Kerr-lens mode locked Ti: sapphire femtosecond laser, photonic crystal fibre and modified, free-space Michelson interferometer. Submicron resolution offered by the UHR-OCT system applied in the study enables registration of both interfaces of the thin encapsulation layer. Complete, volumetric characterisation of protective layers is presented, demonstrating possibility to use OCT for encapsulation quality inspection. © Springer-Verlag 2011.

  8. High resolution computed tomography in patients with various forms of systemic sclerosis

    International Nuclear Information System (INIS)

    Lewszuk, A.; Rozycki, J.; Tarasow, E.; Kowal-Bielecka, O.

    2008-01-01

    Pulmonary lesions are, besides renal and cardiac complications, one of the main causes of mortality among patients with systemic sclerosis (scleroderma). Pathologic changes in the respiratory system take the form of interstitial fibrosis clinically manifested by progressive exertion dyspnea and abnormalities of respiratory restriction type in functional tests. The aim of the study was systematization of pulmonary lesion symptomatology in conventional chest radiography and high resolution computed tomography (HRCT) in patients with various forms of scleroderma, as well as determination of the frequency and localization of the particular lesion types. The study was carried out in a group of 49 patients with systemic sclerosis (47 women and 2 men), who underwent conventional radiography and high resolution computed tomography of the chest. In patients with systemic sclerosis, HRCT revealed most frequently interstitial changes of ground glass type, as well as linear and reticular opacities, whereas bronchiectasis and honeycombing type lesions were less frequent. Pulmonary lesions were seen with increasing frequency towards the lung base and were localized mainly in the posterior, inferior and peripheral parts of the lungs. Comparison of the patients with limited and diffuse scleroderma demonstrated that the diffuse form is associated with more frequent involvement of the respiratory system and more advanced pulmonary lesions. The observed characteristics of pulmonary lesions show similarity between interstitial lung disease in the course of systemic sclerosis and nonspecific interstitial pneumonia (NSIP), which supports classification of interstitial lung disease associated with scleroderma as belonging to that group of interstitial inflammations. (author)

  9. Imaging of dopamine transporters in rats using high-resolution pinhole single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Booij, Jan; Bruin, Kora de; Habraken, Jan B.A. [Department of Nuclear Medicine, F2N, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Voorn, Pieter [Department of Anatomy, Vrije Universiteit Medical Center, Amsterdam (Netherlands)

    2002-09-01

    To date, the vast majority of investigations on the dopaminergic system in small animals have been in vitro studies. In comparison with in vitro studies, single-photon emission tomography (SPET) or positron emission tomography (PET) imaging of the dopaminergic system in small animals has the advantage of permitting repeated studies within the same group of animals. Dopamine transporter imaging is a valuable non-invasive tool with which to investigate the integrity of dopaminergic neurons. The purpose of this study was to investigate the feasibility of assessing dopamine transporter density semi-quantitatively in rats using a recently developed high-resolution pinhole SPET system. This system was built exclusively for imaging of small animals. In this unique single-pinhole system, the animal rotates instead of the collimated detector. The system has proven to have a high spatial resolution. We performed SPET imaging with [{sup 123}I]FP-CIT to quantify striatal dopamine transporters in rat brain. In all seven studied control rats, symmetrical striatal binding to dopamine transporters was seen 2 h after injection of the radiotracer, with striatal-to-cerebellar binding ratios of approximately 3.5. In addition, test/retest variability of the striatal-to-cerebellar binding ratios was studied and found to be 14.5%. Finally, in unilaterally 6-hydroxydopamine-lesioned rats, striatal binding was only visible on the non-lesioned side. Quantitative analysis revealed that striatal-to-cerebellar SPET ratios were significantly lower on the lesioned (mean binding ratio 2.2{+-}0.2) than on the non-lesioned (mean ratio 3.1{+-}0.4) side. The preliminary results of this study indicate that semi-quantitative assessment of striatal dopamine transporter density using our recently developed high-resolution single-pinhole SPET system is feasible in living rat brain. (orig.)

  10. Detector response restoration in image reconstruction of high resolution positron emission tomography

    International Nuclear Information System (INIS)

    Liang, Z.

    1994-01-01

    A mathematical method was studied to model the detector response of high spatial-resolution positron emission tomography systems consisting of close-packed small crystals, and to restore the resolution deteriorated due to crystal penetration and/or nonuniform sampling across the field-of-view (FOV). The simulated detector system had 600 bismuth germanate crystals of 3.14 mm width and 30 mm length packed on a single ring of 60 cm diameter. The space between crystal was filled up with lead. Each crystal was in coincidence with 200 opposite crystals so that the FOV had a radius of 30 cm. The detector response was modeled based on the attenuating properties of the crystals and the septa, as well as the geometry of the detector system. The modeled detector-response function was used to restore the projections from the sinogram of the ring-detector system. The restored projections had a uniform sampling of 1.57 mm across the FOV. The crystal penetration and/or the nonuniform sampling were compensated in the projections. A penalized maximum-likelihood algorithm was employed to accomplish the restoration. The restored projections were then filtered and backprojected to reconstruct the image. A chest phantom with a few small circular ''cold'' objects located at the center and near the periphery of FOV was computer generated and used to test the restoration. The reconstructed images from the restored projections demonstrated resolution improvement off the FOV center, while preserving the resolution near the center

  11. Phase contrast enhanced high resolution X-ray imaging and tomography of soft tissue

    International Nuclear Information System (INIS)

    Jakubek, Jan; Granja, Carlos; Dammer, Jiri; Hanus, Robert; Holy, Tomas; Pospisil, Stanislav; Tykva, Richard; Uher, Josef; Vykydal, Zdenek

    2007-01-01

    A tabletop system for digital high resolution and high sensitivity X-ray micro-radiography has been developed for small-animal and soft-tissue imaging. The system is based on a micro-focus X-ray tube and the semiconductor hybrid position sensitive Medipix2 pixel detector. Transmission radiography imaging, conventionally based only on absorption, is enhanced by exploiting phase-shift effects induced in the X-ray beam traversing the sample. Phase contrast imaging is realized by object edge enhancement. DAQ is done by a novel fully integrated USB-based readout with online image generation. Improved signal reconstruction techniques make use of advanced statistical data analysis, enhanced beam hardening correction and direct thickness calibration of individual pixels. 2D and 3D micro-tomography images of several biological samples demonstrate the applicability of the system for biological and medical purposes including in-vivo and time dependent physiological studies in the life sciences

  12. High-resolution x-ray computed tomography to understand ruminant phylogeny

    Science.gov (United States)

    Costeur, Loic; Schulz, Georg; Müller, Bert

    2014-09-01

    High-resolution X-ray computed tomography has become a vital technique to study fossils down to the true micrometer level. Paleontological research requires the non-destructive analysis of internal structures of fossil specimens. We show how X-ray computed tomography enables us to visualize the inner ear of extinct and extant ruminants without skull destruction. The inner ear, a sensory organ for hearing and balance has a rather complex three-dimensional morphology and thus provides relevant phylogenetical information what has been to date essentially shown in primates. We made visible the inner ears of a set of living and fossil ruminants using the phoenix x-ray nanotom®m (GE Sensing and Inspection Technologies GmbH). Because of the high absorbing objects a tungsten target was used and the experiments were performed with maximum accelerating voltage of 180 kV and a beam current of 30 μA. Possible stem ruminants of the living families are known in the fossil record but extreme morphological convergences in external structures such as teeth is a strong limitation to our understanding of the evolutionary history of this economically important group of animals. We thus investigate the inner ear to assess its phylogenetical potential for ruminants and our first results show strong family-level morphological differences.

  13. High-resolution computed tomography findings in eight patients with hantavirus pulmonary syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Diego de Lacerda; Hochhegger, Bruno; Souza Junior, Arthur Soares; Zanetti, Glaucia; Escuissato, Dante Luiz; Meirelles, Gustavo de Souza Portes; Funari, Marcelo Buarque de Gusmao; Marchiori, Edson, E-mail: edmarchiori@gmail.com [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Santa Casa de Porto Alegre, Porto Alegre, RS (Brazil); Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil); Ultra X, Sao Jose do Rio Preto, SP (Brazil); Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil); Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil); Grupo Fleury, Sao Paulo, SP (Brazil); Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Faculdade de Medicina

    2017-05-15

    Objective: The purpose of this study was to describe the high-resolution computed tomography (HRCT) findings in patients with hantavirus pulmonary syndrome (HPS). Materials and Methods: We retrospectively reviewed HRCT findings from eight cases of HPS. All patients were men, aged 19-70 (mean, 41.7) years. Diagnoses were established by serological test (enzyme-linked immunosorbent assay) in all patients. Two chest radiologists analyzed the images and reached decisions by consensus. Results: The predominant HRCT findings were ground-glass opacities (GGOs) and smooth inter- and intralobular septal thickening, found in all eight cases; however, the crazy-paving pattern was found in only three cases. Pleural effusion and peribronchovascular thickening were observed in five patients. The abnormalities were bilateral in all patients. Conclusion: The predominant HRCT findings in patients with HPS were GGOs and smooth inter- and intralobular septal thickening, which probably correlate with the histopathologic findings of pulmonary edema. (author)

  14. Three dimensional imaging of damage in structural materials using high resolution micro-tomography

    Energy Technology Data Exchange (ETDEWEB)

    Buffiere, J.-Y. [GEMPPM UMR CNRS 5510, INSA Lyon, 20 Av. A. Einstein, 69621 Villeurbanne Cedex (France)]. E-mail: jean-yves.buffiere@insa-lyon.fr; Proudhon, H. [GEMPPM UMR CNRS 5510, INSA Lyon, 20 Av. A. Einstein, 69621 Villeurbanne Cedex (France); Ferrie, E. [GEMPPM UMR CNRS 5510, INSA Lyon, 20 Av. A. Einstein, 69621 Villeurbanne Cedex (France); Ludwig, W. [GEMPPM UMR CNRS 5510, INSA Lyon, 20 Av. A. Einstein, 69621 Villeurbanne Cedex (France); Maire, E. [GEMPPM UMR CNRS 5510, INSA Lyon, 20 Av. A. Einstein, 69621 Villeurbanne Cedex (France); Cloetens, P. [ESRF Grenoble (France)

    2005-08-15

    This paper presents recent results showing the ability of high resolution synchrotron X-ray micro-tomography to image damage initiation and development during mechanical loading of structural metallic materials. First, the initiation, growth and coalescence of porosities in the bulk of two metal matrix composites have been imaged at different stages of a tensile test. Quantitative data on damage development has been obtained and related to the nature of the composite matrix. Second, three dimensional images of fatigue crack have been obtained in situ for two different Al alloys submitted to fretting and/or uniaxial in situ fatigue. The analysis of those images shows the strong interaction of the cracks with the local microstructure and provides unique experimental data for modelling the behaviour of such short cracks.

  15. Three dimensional imaging of damage in structural materials using high resolution micro-tomography

    International Nuclear Information System (INIS)

    Buffiere, J.-Y.; Proudhon, H.; Ferrie, E.; Ludwig, W.; Maire, E.; Cloetens, P.

    2005-01-01

    This paper presents recent results showing the ability of high resolution synchrotron X-ray micro-tomography to image damage initiation and development during mechanical loading of structural metallic materials. First, the initiation, growth and coalescence of porosities in the bulk of two metal matrix composites have been imaged at different stages of a tensile test. Quantitative data on damage development has been obtained and related to the nature of the composite matrix. Second, three dimensional images of fatigue crack have been obtained in situ for two different Al alloys submitted to fretting and/or uniaxial in situ fatigue. The analysis of those images shows the strong interaction of the cracks with the local microstructure and provides unique experimental data for modelling the behaviour of such short cracks

  16. High-resolution computed tomography of cholesteatoma of the middle ear

    International Nuclear Information System (INIS)

    Ishii, Kiyoshi; Fukusumi, Akio; Okudera, Toshio; Kato, Toshihiko; Soda, Toyoji

    1988-01-01

    The high-resolution computed tomography (CT) appearances of 72 consecutive cases (92 ears) of chronic otomastoiditis were reviewed. The cholesteatomas were verified surgically and/or otologically in 35 of these 92 ears. Discussion was made with special emphasis on the differential diagnosis of cholesteatoma of the middle ear from the non-cholesteatoma otitis media. The CT findings suggestive of cholesteatoma were as follows: the definitive findings was of a soft-tissue opacity filling Purssak's space, with a medial displacement of the malleus and the incus; the possible findings were 1) a bony erosion of the wall of the middle ear cavity, 2) a partial or complete disappearance of the malleus and/or the incus, and 3) an opacification of Purssak's space and the superomedial aspect of the external auditory meatus. (author)

  17. Spectrum of high-resolution computed tomography imaging in occupational lung disease.

    Science.gov (United States)

    Satija, Bhawna; Kumar, Sanyal; Ojha, Umesh Chandra; Gothi, Dipti

    2013-10-01

    Damage to the lungs caused by dusts or fumes or noxious substances inhaled by workers in certain specific occupation is known as occupational lung disease. Recognition of occupational lung disease is especially important not only for the primary worker, but also because of the implications with regard to primary and secondary disease prevention in the exposed co-workers. Although many of the disorders can be detected on chest radiography, high-resolution computed tomography (HRCT) is superior in delineating the lung architecture and depicting pathology. The characteristic radiological features suggest the correct diagnosis in some, whereas a combination of clinical features, occupational history, and radiological findings is essential in establishing the diagnosis in others. In the presence of a history of exposure and consistent clinical features, the diagnosis of even an uncommon occupational lung disease can be suggested by the characteristic described HRCT findings. In this article, we briefly review the HRCT appearance of a wide spectrum of occupational lung diseases.

  18. Spectrum of high-resolution computed tomography imaging in occupational lung disease

    International Nuclear Information System (INIS)

    Satija, Bhawna; Kumar, Sanyal; Ojha, Umesh Chandra; Gothi, Dipti

    2013-01-01

    Damage to the lungs caused by dusts or fumes or noxious substances inhaled by workers in certain specific occupation is known as occupational lung disease. Recognition of occupational lung disease is especially important not only for the primary worker, but also because of the implications with regard to primary and secondary disease prevention in the exposed co-workers. Although many of the disorders can be detected on chest radiography, high-resolution computed tomography (HRCT) is superior in delineating the lung architecture and depicting pathology. The characteristic radiological features suggest the correct diagnosis in some, whereas a combination of clinical features, occupational history, and radiological findings is essential in establishing the diagnosis in others. In the presence of a history of exposure and consistent clinical features, the diagnosis of even an uncommon occupational lung disease can be suggested by the characteristic described HRCT findings. In this article, we briefly review the HRCT appearance of a wide spectrum of occupational lung diseases

  19. New microfocus bremsstrahlung source based on betatron B-18 for high-resolution radiography and tomography

    Science.gov (United States)

    Rychkov, M. M.; Kaplin, V. V.; Malikov, E. L.; Smolyanskiy, V. A.; Stepanov, I. B.; Lutsenko, A. S.; Gentsel'man, V.; Vas'kovskiy, I. K.

    2018-01-01

    New microfocus source of hard bremsstrahlung (photon energy > 1 MeV), based on the betatron B-18 with a narrow Ta target inside, for high-resolution radiography and tomography is presented. The first studies of the source demonstrate its possibilities for practical applications to detect the microdefects in products made from heavy materials and to control gaps in joints of parts of composite structures of engineering facilities. The radiography method was used to investigate a compound object consisting of four vertically arranged steel bars between which surfaces were exposed gaps of 10 μm in width. The radiographic image of the object, obtained with a magnification of 2.4, illustrates the good sensitivity of detecting the gaps between adjacent bars, due to the small width of the linear focus of the bremsstrahlung source.

  20. In vivo high resolution human corneal imaging using full-field optical coherence tomography.

    Science.gov (United States)

    Mazlin, Viacheslav; Xiao, Peng; Dalimier, Eugénie; Grieve, Kate; Irsch, Kristina; Sahel, José-Alain; Fink, Mathias; Boccara, A Claude

    2018-02-01

    We present the first full-field optical coherence tomography (FFOCT) device capable of in vivo imaging of the human cornea. We obtained images of the epithelial structures, Bowman's layer, sub-basal nerve plexus (SNP), anterior and posterior stromal keratocytes, stromal nerves, Descemet's membrane and endothelial cells with visible nuclei. Images were acquired with a high lateral resolution of 1.7 µm and relatively large field-of-view of 1.26 mm x 1.26 mm - a combination, which, to the best of our knowledge, has not been possible with other in vivo human eye imaging methods. The latter together with a contactless operation, make FFOCT a promising candidate for becoming a new tool in ophthalmic diagnostics.

  1. High-resolution computed tomography findings in pulmonary complications after bone marrow transplantation: iconographic essay

    International Nuclear Information System (INIS)

    Gasparetto, Emerson L.; Ono, Sergio E.; Souza, Carolina A.; Escuissato, Dante L.; Rocha, Gabriela de Melo; Inoue, Cezar; Falavigna, Joao M.; Marchiori, Edson; Universidade Federal, Rio de Janeiro

    2005-01-01

    Bone marrow transplantation has been the treatment of choice for many hematologic diseases. However, pulmonary complications, which may occur in up to 60% of the patients, are the main cause of treatment failure and may be divided in three phases according to the patient's immunity. In the first phase, up to 30 days after the procedure, there is a predominance of non-infectious complications and fungal pneumonia. Viral infections, mainly by cytomegalovirus, are common in the second phase (up to 100 days after bone marrow transplantation). Finally, in the late phase after bone marrow transplantation, non-infectious complications as bronchiolitis obliterans organizing pneumonia and graft-versus-host disease are most commonly seen. The authors present a pictorial essay of the high-resolution computed tomography findings in patients with pulmonary complications after bone marrow transplantation. (author)

  2. Intrathoracic manifestations of collagen vascular diseases on high-resolution chest computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Silva, C. Isabela S. [University of British Columbia, Vancouver (Canada). Vancouver General Hospital]. E-mail: isabela.silva@vch.ca; Mueller, Nestor L. [University of British Columbia, Vancouver (Canada). Vancouver General Hospital. Dept. of Radiology

    2008-05-15

    Intrathoracic manifestations of collagen vascular diseases are very common. The frequency of intrathoracic manifestations and the patterns of abnormality are variable depending on the type of collagen vascular disease and may simultaneously involve one or more of the following: lung parenchyma, airways, pulmonary vessels, pericardium, and pleura. The most common pulmonary manifestations are diffuse interstitial pneumonia and pulmonary hypertension which together represent the main causes of morbidity and mortality of these patients. Pulmonary, airway and pleural involvement may also be secondary to the disease therapy, or result from bacterial pneumonia or opportunistic infection. In the present review, the authors summarize the main intrathoracic manifestations of collagen vascular diseases and the differential diagnosis on high-resolution chest computed tomography. (author)

  3. High-resolution computed tomography findings in eight patients with hantavirus pulmonary syndrome

    International Nuclear Information System (INIS)

    Barbosa, Diego de Lacerda; Hochhegger, Bruno; Souza Junior, Arthur Soares; Zanetti, Glaucia; Escuissato, Dante Luiz; Meirelles, Gustavo de Souza Portes; Funari, Marcelo Buarque de Gusmao; Marchiori, Edson; Santa Casa de Porto Alegre, Porto Alegre, RS; Faculdade de Medicina de Sao Jose do Rio Preto; Ultra X, Sao Jose do Rio Preto, SP; Universidade Federal do Parana; Universidade Federal de Sao Paulo; Grupo Fleury, Sao Paulo, SP; Universidade de Sao Paulo

    2017-01-01

    Objective: The purpose of this study was to describe the high-resolution computed tomography (HRCT) findings in patients with hantavirus pulmonary syndrome (HPS). Materials and Methods: We retrospectively reviewed HRCT findings from eight cases of HPS. All patients were men, aged 19-70 (mean, 41.7) years. Diagnoses were established by serological test (enzyme-linked immunosorbent assay) in all patients. Two chest radiologists analyzed the images and reached decisions by consensus. Results: The predominant HRCT findings were ground-glass opacities (GGOs) and smooth inter- and intralobular septal thickening, found in all eight cases; however, the crazy-paving pattern was found in only three cases. Pleural effusion and peribronchovascular thickening were observed in five patients. The abnormalities were bilateral in all patients. Conclusion: The predominant HRCT findings in patients with HPS were GGOs and smooth inter- and intralobular septal thickening, which probably correlate with the histopathologic findings of pulmonary edema. (author)

  4. Pulmonary paracoccidioidomycosis: A case report with high-resolution computed tomography findings

    Directory of Open Access Journals (Sweden)

    M. Armas

    2012-07-01

    Full Text Available Paracoccidioidomycosis is a systemic mycosis which is endemic in rural areas of Latin America, an important European source of immigrants and a growing European touristic destination as well, with most cases occurring in Brazil, Argentina, Venezuela and Colombia. The authors report a case of a 43-year-old man who previously worked in Venezuela and is living in Portugal for 8 years, presenting with a single cutaneous lesion. Despite the absence of valuable respiratory complaints, severe lung damage was found with high-resolution computed tomography (HRCT. Biopsy of the cutaneous lesion and mycologic sputum examination were performed revealing Paracoccidioides brasiliensis infection. Resumo: A Paracoccidioidomicose é uma micose sistémica endémica nas áreas rurais da América Latina, uma fonte importante de imigrantes e destino de emigração e turismo europeu, a maioria dos casos ocorrendo no Brasil, Argentina, Venezuela e Colômbia. Os autores descrevem o caso clínico de um paciente com 43 anos, anteriormente emigrado na Venezuela e residente em Portugal há 8 anos, que se apresenta com lesão cutânea isolada. Embora sem queixas relevantes do foro respiratório, apresentava extensas lesões do parênquima pulmonar caracterizadas por tomografia computorizada de alta resolução (TCAR. Foi realizada biópsia da lesão cutânea e exame micológico da expetoração que revelaram infeção por Paracoccidioides brasiliensis (PB. Keywords: Paracoccidioidomycosis, Paracoccidioides brasiliensis, Pulmonary fibrosis, High-resolution computed tomography, Palavras-chave: Paracoccidioidomicose, Paracoccidioides brasiliensis, Fibrose pulmonar, Tomografia computorizada de alta resolução

  5. Toward robust high resolution fluorescence tomography: a hybrid row-action edge preserving regularization

    Science.gov (United States)

    Behrooz, Ali; Zhou, Hao-Min; Eftekhar, Ali A.; Adibi, Ali

    2011-02-01

    Depth-resolved localization and quantification of fluorescence distribution in tissue, called Fluorescence Molecular Tomography (FMT), is highly ill-conditioned as depth information should be extracted from limited number of surface measurements. Inverse solvers resort to regularization algorithms that penalize Euclidean norm of the solution to overcome ill-posedness. While these regularization algorithms offer good accuracy, their smoothing effects result in continuous distributions which lack high-frequency edge-type features of the actual fluorescence distribution and hence limit the resolution offered by FMT. We propose an algorithm that penalizes the total variation (TV) norm of the solution to preserve sharp transitions and high-frequency components in the reconstructed fluorescence map while overcoming ill-posedness. The hybrid algorithm is composed of two levels: 1) An Algebraic Reconstruction Technique (ART), performed on FMT data for fast recovery of a smooth solution that serves as an initial guess for the iterative TV regularization, 2) A time marching TV regularization algorithm, inspired by the Rudin-Osher-Fatemi TV image restoration, performed on the initial guess to further enhance the resolution and accuracy of the reconstruction. The performance of the proposed method in resolving fluorescent tubes inserted in a liquid tissue phantom imaged by a non-contact CW trans-illumination FMT system is studied and compared to conventional regularization schemes. It is observed that the proposed method performs better in resolving fluorescence inclusions at higher depths.

  6. Comparison between high-resolution computed tomography and 99mTc-technegas SPECT pulmonary emphysema

    International Nuclear Information System (INIS)

    Nakano, Satoru; Satoh, Katashi; Takahashi, Kazue

    1996-01-01

    Scintigraphy with 99m Tc-technegas was recently introduced for clinical imaging of lung ventilation. This method has been found to be useful in emergencies, to be more suitable for single photon emission computed tomography (SPECT) than other agents used in ventilation scintigraphy, and could reveal abnormalities in ventilation more easily than high resolution computed tomography (HRCT) in pulmonary emphysema. We compared 99m Tc-technegas SPECT with HRCT in six regions: the right upper, middle, and lower lobes, the left upper lobe, the lingula, and the left lower lobe, in 15 patients with pulmonary emphysema. Patients with centrilobular emphysema tended to show stronger changes in upper lobes than in lower lobes on both 99m Tc-technegas SPECT and HRCT. Some regions showed no change on HRCT but various changes on 99m Tc-SPECT. Patients with panlobular emphysema showed severe changes on 99m Tc-SPECT in lower lung fields in which well-demarcated areas of low attenuation were not seen on HRCT. We conclude that 99m Tc-SPECT is useful for detecting early changes and panlobular changes in pulmonary emphysema. (author)

  7. Ground-glass opacity in diffuse lung diseases: high-resolution computed tomography-pathology correlation

    International Nuclear Information System (INIS)

    Santos, Maria Lucia de Oliveira; Vianna, Alberto Domingues; Marchiori, Edson; Souza Junior, Arthur Soares; Moraes, Heleno Pinto de

    2003-01-01

    Ground-glass opacity is a finding frequently seen in high-resolution computed tomography examinations of the chest and is characterized by hazy increased attenuation of lung, however without blurring of bronchial and vascular margins. Due to its un specificity, association with other radiological, clinical and pathological findings must be considered for an accurate diagnostic interpretation. In this paper were reviewed 62 computed tomography examinations of patients with diffuse pulmonary diseases of 14 different etiologies in which ground-glass opacity was the only or the most remarkable finding, and correlated this findings with pathology abnormalities seen on specimens obtained from biopsies or necropsies. In pneumocystosis, ground-glass opacities correlated histologically with alveolar occupation by a foaming material containing parasites, in bronchiole alveolar cell carcinoma with thickening of the alveolar septa and occupation of the lumen by mucus and tumoral cells, in paracoccidioidomycosis with thickening of the alveolar septa, areas of fibrosis and alveolar bronchopneumonia exudate, in sarcoidosis with fibrosis or clustering of granulomas and in idiopathic pulmonary fibrosis with alveolar septa thickening due to fibrosis. Alveolar occupation by blood was found in cases of leptospirosis, idiopathic hemo siderosis, metastatic kidney tumor and invasive aspergillosis whereas oily vacuole were seen in lipoid pneumonia, proteinaceous and lipo proteinaceous material in silico proteinosis and pulmonary alveolar proteinosis, and edematous fluid in cardiac failure. (author)

  8. The Spectrum of Presentations of Cryptogenic Organizing Pneumonia in High Resolution Computed Tomography

    International Nuclear Information System (INIS)

    Mehrian, Payam; Shahnazi, Makhtoom; Dahaj, Ali Ahmadi; Bizhanzadeh, Sorour; Karimi, Mohammad Ali

    2014-01-01

    Various radiologic patterns of cryptogenic organizing pneumonia (COP) in X-rays have been reported for more than 20 years, and later, in computed tomography scans. The aim of the present study was to describe the spectrum of radiologic findings on high resolution computed tomography (HRCT) scans in patients with COP. HRCT scans of 31 sequential patients (mean age: 54.3±11 years; 55% male) with biopsy-proven COP in a tertiary lung center between 2009 and 2012 were reviewed by two experienced pulmonary radiologists with almost perfect interobserver agreement (kappa=0.83). Chest HRCTs from the lung apex to the base were performed using a 16-slice multi-detector CT scanner. The most common HRCT presentation of COP was ground-glass opacity (GGO) in 83.9% of cases, followed by consolidation in 71%. Both findings were mostly asymmetric bilateral and multifocal. Other common findings were the reverse halo (48.4%), parenchymal bands (54.8%) and subpleural bands (32.3%). Pulmonary nodules were found in about one-third of patients and were frequently smaller than 5 mm in diameter. Both GGOs and consolidations were revealed more often in the lower lobes. The main presentations of COP on HRCT include bilateral GGOs and consolidations in the lower lobes together with the reverse halo sign

  9. Clinical cone beam computed tomography compared to high-resolution peripheral computed tomography in the assessment of distal radius bone.

    Science.gov (United States)

    de Charry, C; Boutroy, S; Ellouz, R; Duboeuf, F; Chapurlat, R; Follet, H; Pialat, J B

    2016-10-01

    Clinical cone beam computed tomography (CBCT) was compared to high-resolution peripheral quantitative computed tomography (HR-pQCT) for the assessment of ex vivo radii. Strong correlations were found for geometry, volumetric density, and trabecular structure. Using CBCT, bone architecture assessment was feasible but compared to HR-pQCT, trabecular parameters were overestimated whereas cortical ones were underestimated. HR-pQCT is the most widely used technique to assess bone microarchitecture in vivo. Yet, this technology has been only applicable at peripheral sites, in only few research centers. Clinical CBCT is more widely available but quantitative assessment of the bone structure is usually not performed. We aimed to compare the assessment of bone structure with CBCT (NewTom 5G, QR, Verona, Italy) and HR-pQCT (XtremeCT, Scanco Medical AG, Brüttisellen, Switzerland). Twenty-four distal radius specimens were scanned with these two devices with a reconstructed voxel size of 75 μm for Newtom 5G and 82 μm for XtremeCT, respectively. A rescaling-registration scheme was used to define the common volume of interest. Cortical and trabecular compartments were separated using a semiautomated double contouring method. Density and microstructure were assessed with the HR-pQCT software on both modality images. Strong correlations were found for geometry parameters (r = 0.98-0.99), volumetric density (r = 0.91-0.99), and trabecular structure (r = 0.94-0.99), all p < 0.001. Correlations were lower for cortical microstructure (r = 0.80-0.89), p < 0.001. However, absolute differences were observed between modalities for all parameters, with an overestimation of the trabecular structure (trabecular number, 1.62 ± 0.37 vs. 1.47 ± 0.36 mm(-1)) and an underestimation of the cortical microstructure (cortical porosity, 3.3 ± 1.3 vs. 4.4 ± 1.4 %) assessed on CBCT images compared to HR-pQCT images. Clinical CBCT devices are able to

  10. Persistent asthma in adults: comparison of high resolution computed tomography of the lungs after one year of follow-up

    International Nuclear Information System (INIS)

    Cukier, Alberto; Stelmach, Rafael; Kavakama, Jorge Issamu; Terra Filho, Mario; Vargas, Francisco

    2001-01-01

    The aims of this study were to evaluate the role of high resolution computed tomography of the thorax in detecting abnormalities in chronic asthmatic patients and to determine the behavior of these lesions after at least one year. Fourteen persistent asthmatic patients with a mean forced expiratory volume in 1-second that was 63% of predicted and a mean forced expiratory volume in 1-second /forced vital capacity of 60% had two high resolution computed tomography separated by an interval of at least one year. All 14 patients had abnormalities on both scans. The most common abnormality was bronchial wall thickening, which was present in all patients on both computed tomography. Bronchiectasis was suggested on the first computed tomography in 5 of the 14 (36%) patients, but on follow-up, the bronchial dilatation had disappeared in 2 and diminished in a third. Only one patient had any emphysematous changes; a minimal persistent area of para septal emphysema was present on both scans. In 3 patients, a 'mosaic' appearance was observed on the first scan, and this persisted on the follow-up computed tomography. Two patients had persistent areas of mucoid impaction. In a third patient, mucus plugging was detected only on the second computed tomography. We conclude that there are many abnormalities on the high resolution computed tomography of patients with persistent asthma. Changes suggestive of bronchiectasis, namely bronchial dilatation, frequently resolve spontaneously. Therefore, the diagnosis of bronchiectasis by high resolution computed tomography in asthmatic patients must be made with caution, since bronchial dilatation can be reversible or can represent false dilatation. Non smoking chronic asthmatic subjects in this study had no evidence of centrilobular or panacinar emphysema. (author)

  11. High-resolution tomography of positron emitters with clustered pinhole SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Goorden, Marlies C; Beekman, Freek J [Section of Radiation Detection and Medical Imaging, Applied Sciences, Delft University of Technology, Mekelweg 15, 2629 JB Delft (Netherlands)], E-mail: m.c.goorden@tudelft.nl

    2010-03-07

    State-of-the-art small-animal single photon emission computed tomography (SPECT) enables sub-half-mm resolution imaging of radio-labelled molecules. Due to severe photon penetration through pinhole edges, current multi-pinhole SPECT is not suitable for high-resolution imaging of photons with high energies, such as the annihilation photons emitted by positron emitting tracers (511 keV). To deal with this edge penetration, we introduce here clustered multi-pinhole SPECT (CMP): each pinhole in a cluster has a narrow opening angle to reduce photon penetration. Using simulations, CMP is compared with (i) a collimator with traditional pinholes that is currently used for sub-half-mm imaging of SPECT isotopes (U-SPECT-II), and (ii), like (i) but with collimator thickness adapted to image high-energy photons (traditional multi-pinhole SPECT, TMP). At 511 keV, U-SPECT-II is able to resolve the 0.9 mm rods of an iteratively reconstructed Jaszczak-like capillary hot rod phantom, and while TMP only leads to small improvements, CMP can resolve rods as small as 0.7 mm. Using a digital tumour phantom, we show that CMP resolves many details not assessable with standard USPECT-II and TMP collimators. Furthermore, CMP makes it possible to visualize uptake of positron emitting tracers in sub-compartments of a digital mouse striatal brain phantom. This may open up unique possibilities for analysing processes such as those underlying the function of neurotransmitter systems. Additional potential of CMP may include (i) the imaging of other high-energy single-photon emitters (e.g. I-131) and (ii) localized imaging of positron emitting tracers simultaneously with single photon emitters, with an even better resolution than coincidence PET.

  12. High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography

    Science.gov (United States)

    Larsson, Daniel H.; Vågberg, William; Yaroshenko, Andre; Yildirim, Ali Önder; Hertz, Hans M.

    2016-12-01

    X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-power small-spot liquid-metal-jet electron-impact source. The tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.

  13. Development of a multiplexed readout with high position resolution for positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sangwon; Choi, Yong [Molecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul 04107 (Korea, Republic of); Kang, Jihoon [Department of Biomedical Engineering, Chonnam National University, Yeosu 550-749 (Korea, Republic of); Jung, Jin Ho [Molecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul 04107 (Korea, Republic of)

    2017-04-01

    Detector signals for positron emission tomography (PET) are commonly multiplexed to reduce the number of digital processing channels so that the system can remain cost effective while also maintaining imaging performance. In this work, a multiplexed readout combining Anger position estimation algorithm and position decoder circuit (PDC) was developed to reduce the number of readout channels by a factor of 24, 96-to-4. The data acquisition module consisted of a TDC (50 ps resolution), 4-channel ADCs (12 bit, 105 MHz sampling rate), 2 GB SDRAM and USB3.0. The performance of the multiplexed readout was assessed with a high-resolution PET detector block composed of 2×3 detector modules, each consisting of an 8×8 array of 1.52×1.52×6 mm{sup 3} LYSO, a 4×4 array of 3×3 mm{sup 2} silicon photomultiplier (SiPM) and 13.4×13.4 mm{sup 2} light guide with 0.7 mm thickness. The acquired flood histogram showed that all 384 crystals could be resolved. The average energy resolution at 511 keV was 13.7±1.6% full-width-at-half-maximum (FWHM) and the peak-to-valley ratios of the flood histogram on the horizontal and vertical lines were 18.8±0.8 and 22.8±1.3, respectively. The coincidence resolving time of a pair of detector blocks was 6.2 ns FWHM. The reconstructed phantom image showed that rods down to a diameter of 1.6 mm could be resolved. The results of this study indicate that the multiplexed readout would be useful in developing a PET with a spatial resolution less than the pixel size of the photosensor, such as a SiPM array.

  14. Early-state damage detection, characterization, and evolution using high-resolution computed tomography

    Science.gov (United States)

    Grandin, Robert John

    Safely using materials in high performance applications requires adequately understanding the mechanisms which control the nucleation and evolution of damage. Most of a material's operational life is spent in a state with noncritical damage, and, for example in metals only a small portion of its life falls within the classical Paris Law regime of crack growth. Developing proper structural health and prognosis models requires understanding the behavior of damage in these early stages within the material's life, and this early-stage damage occurs on length scales at which the material may be considered "granular'' in the sense that the discrete regions which comprise the whole are large enough to require special consideration. Material performance depends upon the characteristics of the granules themselves as well as the interfaces between granules. As a result, properly studying early-stage damage in complex, granular materials requires a means to characterize changes in the granules and interfaces. The granular-scale can range from tenths of microns in ceramics, to single microns in fiber-reinforced composites, to tens of millimeters in concrete. The difficulty of direct-study is often overcome by exhaustive testing of macro-scale damage caused by gross material loads and abuse. Such testing, for example optical or electron microscopy, destructive and further, is costly when used to study the evolution of damage within a material and often limits the study to a few snapshots. New developments in high-resolution computed tomography (HRCT) provide the necessary spatial resolution to directly image the granule length-scale of many materials. Successful application of HRCT with fiber-reinforced composites, however, requires extending the HRCT performance beyond current limits. This dissertation will discuss improvements made in the field of CT reconstruction which enable resolutions to be pushed to the point of being able to image the fiber-scale damage structures and

  15. South Ilan Plain High-Resolution 3-D S-Wave Velocity from Ambient Noise Tomography

    Directory of Open Access Journals (Sweden)

    Kai-Xun Chen

    2016-06-01

    Full Text Available The Ilan Plain in northeastern Taiwan is located at a pivotal point where the Ryukyu trench subduction zone, the northern Taiwan crustal stretching zone, and the ongoing arc-continent collision zone converge. In contrast to the North Ilan Plain, the South Ilan Plain exhibits a thin unconsolidated sedimentary layer with depths ranging from 0 - 1 km, high on-land seismicity and significant SE movements relative to Penghu island. We deployed a dense network of 43 short-period vertical component Texan instruments from June to November 2013 in this study, covering most of the South Ilan Plain and its vicinity. We then used the ambient noise tomography method for simultaneous phase and group Rayleigh wave velocity measurements to invert a high-resolution 3-D S-wave for shallow structures (up to a depth of 2.5 km in the South Ilan Plain. We used the fast marching method for ray tracing to deal with ray bending in an inhomogeneous medium. The resulting rays gradually bend toward high velocity zones with increasing number of iterations. The high velocity zone results are modified by more iterations and the resolutions become higher because ray crossings are proportional to ray densities for evenly distributed stations. The final results agreed well with known sedimentary basement thickness patterns. We observed nearly EW trending fast anomalies beneath the mountainous terrain abutting to the South Ilan Plain. The Chingshui location consistently exhibited a low S-wave velocity zone to a depth of 1.5 km.

  16. Use of a YAP:Ce matrix coupled to a position-sensitive photomultiplier for high resolution positron emission tomography

    International Nuclear Information System (INIS)

    Del Guerra, A.; Zavattini, G.; Notaristefani, F. de; Giganti, M.; Piffanelli, A.; Pani, R.; Turra, A.

    1996-01-01

    A new scintillation detector system has been designed for application in high resolution Positron Emission Tomography (PET). The detector is a bundle of small YAlO 3 :Ce (YAP) crystals closely packed (0.2 x 0.2 x 3.0 cm 3 ), coupled to a position sensitive photomultiplier tube (PSPMT). The preliminary results obtained for spatial resolution, time resolution, energy resolution and efficiency of two such detectors working in coincidence are presented. These are 1.2 mm for the FWHM spatial resolution, 2.0 ns for the FWHM time resolution and 20% for the FWHM energy resolution at 511 keV. The measured efficiency is (44 ± 3)% with a 150 keV threshold and (20 ± 2)% with a 300 keV threshold

  17. Metastatic pulmonary calcification: high-resolution computed tomography findings in 23 cases

    Directory of Open Access Journals (Sweden)

    Luciana Camara Belém

    Full Text Available Abstract Objective: The aim of this study was to evaluate the high-resolution computed tomography (HRCT findings in patients diagnosed with metastatic pulmonary calcification (MPC. Materials and Methods: We retrospectively reviewed the HRCT findings from 23 cases of MPC [14 men, 9 women; mean age, 54.3 (range, 26-89 years]. The patients were examined between 2000 and 2014 in nine tertiary hospitals in Brazil, Chile, and Canada. Diagnoses were established by histopathologic study in 18 patients and clinical-radiological correlation in 5 patients. Two chest radiologists analyzed the images and reached decisions by consensus. Results: The predominant HRCT findings were centrilobular ground-glass nodules (n = 14; 60.9%, consolidation with high attenuation (n = 10; 43.5%, small dense nodules (n = 9; 39.1%, peripheral reticular opacities associated with small calcified nodules (n = 5; 21.7%, and ground-glass opacities without centrilobular ground-glass nodular opacity (n = 5; 21.7%. Vascular calcification within the chest wall was found in four cases and pleural effusion was observed in five cases. The abnormalities were bilateral in 21 cases. Conclusion: MPC manifested with three main patterns on HRCT, most commonly centrilobular ground-glass nodules, often containing calcifications, followed by dense consolidation and small solid nodules, most of which were calcified. We also described another pattern of peripheral reticular opacities associated with small calcified nodules. These findings should suggest the diagnosis of MPC in the setting of hypercalcemia.

  18. Metastatic pulmonary calcification: high-resolution computed tomography findings in 23 cases

    Energy Technology Data Exchange (ETDEWEB)

    Belem, Luciana Camara; Souza, Carolina A.; Souza Junior, Arthur Soares; Escuissato, Dante Luiz; Hochhegger, Bruno; Nobre, Luiz Felipe; Rodrigues, Rosana Souza; Gomes, Antonio Carlos Portugal; Silva, Claudio S.; Guimaraes, Marcos Duarte; Zanetti, Glaucia; Marchiori, Edson, E-mail: edmarchiori@gmail.com [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Ottawa Hospital Research Institute, University of Ottawa, (Canada); Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil); Ultra X, Sao Jose do Rio Preto, SP (Brazil); Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil); Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), Porto Alegre, RS (Brazil); Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil). Hospital Universitario

    2017-07-15

    Objective: The aim of this study was to evaluate the high-resolution computed tomography (HRCT) findings in patients diagnosed with metastatic pulmonary calcification (MPC). Materials and Methods: We retrospectively reviewed the HRCT findings from 23 cases of MPC [14 men, 9 women; mean age, 54.3 (range, 26-89) years]. The patients were examined between 2000 and 2014 in nine tertiary hospitals in Brazil, Chile, and Canada. Diagnoses were established by histopathologic study in 18 patients and clinical-radiological correlation in 5 patients. Two chest radiologists analyzed the images and reached decisions by consensus. Results: The predominant HRCT findings were centrilobular ground-glass nodules (n = 14; 60.9%), consolidation with high attenuation (n = 10; 43.5%), small dense nodules (n = 9; 39.1%), peripheral reticular opacities associated with small calcified nodules (n = 5; 21.7%), and ground-glass opacities without centrilobular ground-glass nodular opacity (n = 5; 21.7%). Vascular calcification within the chest wall was found in four cases and pleural effusion was observed in five cases. The abnormalities were bilateral in 21 cases. Conclusion: MPC manifested with three main patterns on HRCT, most commonly centrilobular ground-glass nodules, often containing calcifications, followed by dense consolidation and small solid nodules, most of which were calcified. We also described another pattern of peripheral reticular opacities associated with small calcified nodules. These findings should suggest the diagnosis of MPC in the setting of hypercalcemia. (author)

  19. In vivo monitoring laser tissue interaction using high resolution Fourier-domain optical coherence tomography

    Science.gov (United States)

    Jo, Hang Chan; Shin, Dong Jun; Ahn, Jin-Chul; Chung, Phil-Sang; Kim, DaeYu

    2017-02-01

    Laser-induced therapies include laser ablation to remove or cut target tissue by irradiating high-power focused laser beam. These laser treatments are widely used tools for minimally invasive surgery and retinal surgical procedures in clinical settings. In this study, we demonstrate laser tissue interaction images of various sample tissues using high resolution Fourier-domain optical coherence tomography (Fd-OCT). We use a Q-switch diode-pumped Nd:YVO4 nanosecond laser (532nm central wavelength) with a 4W maximum output power at a 20 kHz repetition rate to ablate in vitro and in vivo samples including chicken breast and mouse ear tissues. The Fd-OCT system acquires time-series Bscan images at the same location during the tissue ablation experiments with 532nm laser irradiation. The real-time series of OCT cross-sectional (B-scan) images compare structural changes of 532nm laser ablation using same and different laser output powers. Laser tissue ablation is demonstrated by the width and the depth of the tissue ablation from the B-scan images.

  20. [Diagnostic value of high-resolution computed tomography imaging in congenital inner ear malformations].

    Science.gov (United States)

    Sun, Xiaowei; Ding, Yuanping; Zhang, Jianji; Chen, Ying; Xu, Anting; Dou, Fenfen; Zhang, Zihe

    2007-02-01

    To observe the inner ear structure with volume rendering (VR) reconstruction and to evaluate the role of high-resolution computed tomography (HRCT) in congenital inner ear malformations. HRCT scanning was performed in 10 patients (20 ears) without ear disease (control group) and 7 patients (11 ears) with inner ear malformations (IEM group) and the original data was processed with VR reconstruction. The inner ear osseous labyrinth structure in the images generated by these techniques was observed respectively in the normal ears and malformation ears. The inner ear osseous labyrinth structure and the relationship was displayed clearly in VR imaging in the control group,meanwhile, characters and degree of malformed structure were also displayed clearly in the IEA group. Of seven patients (11 ears) with congenital inner ear malformations, the axial, MPR and VR images can display the site and degree in 9 ears. VR images were superior to the axial images in displaying the malformations in 2 ears with the small lateral semicircular canal malformations. The malformations included Mondini deformity (7 ears), vestibular and semicircular canal malformations (3 ears), vestibular aqueduct dilate (7 ears, of which 6 ears accompanied by other malformations) , the internal auditory canal malformation (2 ears, all accompanied by other malformations). HRCT can display the normal structure of bone inner ear through high quality VR reconstructions. VR images can also display the site and degree of the malformations three-dimensionally and intuitively. HRCT is valuable in diagnosing the inner ear malformation.

  1. Metastatic pulmonary calcification: high-resolution computed tomography findings in 23 cases

    International Nuclear Information System (INIS)

    Belem, Luciana Camara; Souza, Carolina A.; Souza Junior, Arthur Soares; Escuissato, Dante Luiz; Hochhegger, Bruno; Nobre, Luiz Felipe; Rodrigues, Rosana Souza; Gomes, Antonio Carlos Portugal; Silva, Claudio S.; Guimaraes, Marcos Duarte; Zanetti, Glaucia; Marchiori, Edson; Ottawa Hospital Research Institute, University of Ottawa,; Faculdade de Medicina de Sao Jose do Rio Preto; Ultra X, Sao Jose do Rio Preto, SP; Universidade Federal do Parana; Universidade Federal de Ciencias da Saude de Porto Alegre; Universidade Federal de Santa Catarina

    2017-01-01

    Objective: The aim of this study was to evaluate the high-resolution computed tomography (HRCT) findings in patients diagnosed with metastatic pulmonary calcification (MPC). Materials and Methods: We retrospectively reviewed the HRCT findings from 23 cases of MPC [14 men, 9 women; mean age, 54.3 (range, 26-89) years]. The patients were examined between 2000 and 2014 in nine tertiary hospitals in Brazil, Chile, and Canada. Diagnoses were established by histopathologic study in 18 patients and clinical-radiological correlation in 5 patients. Two chest radiologists analyzed the images and reached decisions by consensus. Results: The predominant HRCT findings were centrilobular ground-glass nodules (n = 14; 60.9%), consolidation with high attenuation (n = 10; 43.5%), small dense nodules (n = 9; 39.1%), peripheral reticular opacities associated with small calcified nodules (n = 5; 21.7%), and ground-glass opacities without centrilobular ground-glass nodular opacity (n = 5; 21.7%). Vascular calcification within the chest wall was found in four cases and pleural effusion was observed in five cases. The abnormalities were bilateral in 21 cases. Conclusion: MPC manifested with three main patterns on HRCT, most commonly centrilobular ground-glass nodules, often containing calcifications, followed by dense consolidation and small solid nodules, most of which were calcified. We also described another pattern of peripheral reticular opacities associated with small calcified nodules. These findings should suggest the diagnosis of MPC in the setting of hypercalcemia. (author)

  2. Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner

    Science.gov (United States)

    Kakinuma, Ryutaro; Moriyama, Noriyuki; Muramatsu, Yukio; Gomi, Shiho; Suzuki, Masahiro; Nagasawa, Hirobumi; Kusumoto, Masahiko; Aso, Tomohiko; Muramatsu, Yoshihisa; Tsuchida, Takaaki; Tsuta, Koji; Maeshima, Akiko Miyagi; Tochigi, Naobumi; Watanabe, Shun-ichi; Sugihara, Naoki; Tsukagoshi, Shinsuke; Saito, Yasuo; Kazama, Masahiro; Ashizawa, Kazuto; Awai, Kazuo; Honda, Osamu; Ishikawa, Hiroyuki; Koizumi, Naoya; Komoto, Daisuke; Moriya, Hiroshi; Oda, Seitaro; Oshiro, Yasuji; Yanagawa, Masahiro; Tomiyama, Noriyuki; Asamura, Hisao

    2015-01-01

    Purpose The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. Materials and Methods This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm x 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm x 16 or 0.5 mm x 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner. Results The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU]) was greater than that for C-HRCT (40.41 ± 0.52 HU; P < .0001). The image quality of U-HRCT was graded as superior to that of C-HRCT (P < .0001) for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary vessels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures. Conclusion Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners. PMID:26352144

  3. Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner.

    Directory of Open Access Journals (Sweden)

    Ryutaro Kakinuma

    Full Text Available The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT scanners.This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm x 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm x 16 or 0.5 mm x 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner.The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU] was greater than that for C-HRCT (40.41 ± 0.52 HU; P < .0001. The image quality of U-HRCT was graded as superior to that of C-HRCT (P < .0001 for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary vessels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures.Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners.

  4. Chronic hypersensitivity pneumonitis: high resolution computed tomography patterns and pulmonary function indices as prognostic determinants

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Simon L.F.; Devaraj, Anand; Hansell, David M. [Royal Brompton Hospital, Department of Radiology, London (United Kingdom); Sverzellati, Nicola [University of Parma, Department of Clinical Sciences, Section of Radiology, Parma (Italy); Wells, Athol U. [Royal Brompton Hospital, Interstitial Lung Diseases Unit, London (United Kingdom)

    2012-08-15

    To investigate high resolution computed tomography (HRCT) and pulmonary function indices (PFTs) for determining prognosis in patients with chronic fibrotic hypersensitivity pneumonitis (CHP). Case records, PFTs (FEV{sub 1}, FVC and DLco) and HRCTs of ninety-two patients with chronic hypersensitivity pneumonitis were evaluated. HRCT studies were scored by two observers for total disease extent, ground-glass opacification, fine and coarse reticulation, microcystic and macrocystic honeycombing, centrilobular emphysema and consolidation. Traction bronchiectasis within each pattern was graded. Using Cox proportional hazards regression models the prognostic strength of individual HRCT patterns and pulmonary function test variables were determined. There were forty two deaths during the study period. Increasing severity of traction bronchiectasis was the strongest predictor of mortality (HR 1.10, P < 0.001, 95%CI 1.04-1.16). Increasing global interstitial disease extent (HR 1.02, P = 0.02, 95%CI 1.00-1.03), microcystic honeycombing (HR 1.09, P = 0.019, 95%CI 1.01-1.17) and macrocystic honeycombing (HR 1.06, P < 0.01, 95%CI 1.01-1.10) were also independent predictors of mortality. In contrast, no individual PFT variable was predictive of mortality once HRCT patterns were accounted for. HRCT patterns, in particular, severity of traction bronchiectasis and extent of honeycombing are superior to pulmonary function tests for predicting mortality in patients with CHP. (orig.)

  5. High-resolution computed tomography in silicosis: correlation with chest radiography and pulmonary function tests

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Agnaldo Jose [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Pedro Ernesto Univ. Hospital. Dept. of Respiratory Function]. E-mail: phel.lop@uol.com.br; Mogami, Roberto; Capone, Domenico; Jansen, Jose Manoel [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). School of Medical Sciences; Tessarollo, Bernardo [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Dept. of Radiology and Diagnostic Image; Melo, Pedro Lopes de [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. of Biology

    2008-05-15

    Objective: To correlate tomographic findings with pulmonary function findings, as well as to compare chest X-ray findings with high-resolution computed tomography (HRCT) findings, in patients with silicosis. Methods: A cross-sectional study was conducted in 44 non-smoking patients without a history of tuberculosis. Chest X-ray findings were classified according to the International Labour Organization recommendations. Using a semiquantitative system, the following HRCT findings were measured: the full extent of pulmonary involvement; parenchymal opacities; and emphysema. Spirometry and forced oscillation were performed. Pulmonary volumes were evaluated using the helium dilution method, and diffusing capacity of the lung for carbon monoxide was assessed. Results: Of the 44 patients studied, 41 were male. The mean age was 48.4 years. There were 4 patients who were classified as category 0 based on X-ray findings and as category 1 based on HRCT findings. Using HRCT scans, we identified progressive massive fibrosis in 33 patients, compared with only 23 patients when X-rays were used. Opacity score was found to correlate most closely with airflow, DLCO and compliance. Emphysema score correlated inversely with volume, DLCO and airflow. In this sample of patients presenting a predominance of large opacities (75% of the individuals), the deterioration of pulmonary function was associated with the extent of structural changes. Conclusions: In the early detection of silicosis and the identification of progressive massive fibrosis, HRCT scans are superior to X-rays. (author)

  6. High-resolution computed tomography in silicosis: correlation with chest radiography and pulmonary function tests

    International Nuclear Information System (INIS)

    Lopes, Agnaldo Jose; Mogami, Roberto; Capone, Domenico; Jansen, Jose Manoel; Tessarollo, Bernardo; Melo, Pedro Lopes de

    2008-01-01

    Objective: To correlate tomographic findings with pulmonary function findings, as well as to compare chest X-ray findings with high-resolution computed tomography (HRCT) findings, in patients with silicosis. Methods: A cross-sectional study was conducted in 44 non-smoking patients without a history of tuberculosis. Chest X-ray findings were classified according to the International Labour Organization recommendations. Using a semiquantitative system, the following HRCT findings were measured: the full extent of pulmonary involvement; parenchymal opacities; and emphysema. Spirometry and forced oscillation were performed. Pulmonary volumes were evaluated using the helium dilution method, and diffusing capacity of the lung for carbon monoxide was assessed. Results: Of the 44 patients studied, 41 were male. The mean age was 48.4 years. There were 4 patients who were classified as category 0 based on X-ray findings and as category 1 based on HRCT findings. Using HRCT scans, we identified progressive massive fibrosis in 33 patients, compared with only 23 patients when X-rays were used. Opacity score was found to correlate most closely with airflow, DLCO and compliance. Emphysema score correlated inversely with volume, DLCO and airflow. In this sample of patients presenting a predominance of large opacities (75% of the individuals), the deterioration of pulmonary function was associated with the extent of structural changes. Conclusions: In the early detection of silicosis and the identification of progressive massive fibrosis, HRCT scans are superior to X-rays. (author)

  7. Spectrum of high-resolution computed tomography imaging in occupational lung disease

    Directory of Open Access Journals (Sweden)

    Bhawna Satija

    2013-01-01

    Full Text Available Damage to the lungs caused by dusts or fumes or noxious substances inhaled by workers in certain specific occupation is known as occupational lung disease. Recognition of occupational lung disease is especially important not only for the primary worker, but also because of the implications with regard to primary and secondary disease prevention in the exposed co-workers. Although many of the disorders can be detected on chest radiography, high-resolution computed tomography (HRCT is superior in delineating the lung architecture and depicting pathology. The characteristic radiological features suggest the correct diagnosis in some, whereas a combination of clinical features, occupational history, and radiological findings is essential in establishing the diagnosis in others. In the presence of a history of exposure and consistent clinical features, the diagnosis of even an uncommon occupational lung disease can be suggested by the characteristic described HRCT findings. In this article, we briefly review the HRCT appearance of a wide spectrum of occupational lung diseases.

  8. Chronic hypersensitivity pneumonitis: high resolution computed tomography patterns and pulmonary function indices as prognostic determinants

    International Nuclear Information System (INIS)

    Walsh, Simon L.F.; Devaraj, Anand; Hansell, David M.; Sverzellati, Nicola; Wells, Athol U.

    2012-01-01

    To investigate high resolution computed tomography (HRCT) and pulmonary function indices (PFTs) for determining prognosis in patients with chronic fibrotic hypersensitivity pneumonitis (CHP). Case records, PFTs (FEV 1 , FVC and DLco) and HRCTs of ninety-two patients with chronic hypersensitivity pneumonitis were evaluated. HRCT studies were scored by two observers for total disease extent, ground-glass opacification, fine and coarse reticulation, microcystic and macrocystic honeycombing, centrilobular emphysema and consolidation. Traction bronchiectasis within each pattern was graded. Using Cox proportional hazards regression models the prognostic strength of individual HRCT patterns and pulmonary function test variables were determined. There were forty two deaths during the study period. Increasing severity of traction bronchiectasis was the strongest predictor of mortality (HR 1.10, P < 0.001, 95%CI 1.04-1.16). Increasing global interstitial disease extent (HR 1.02, P = 0.02, 95%CI 1.00-1.03), microcystic honeycombing (HR 1.09, P = 0.019, 95%CI 1.01-1.17) and macrocystic honeycombing (HR 1.06, P < 0.01, 95%CI 1.01-1.10) were also independent predictors of mortality. In contrast, no individual PFT variable was predictive of mortality once HRCT patterns were accounted for. HRCT patterns, in particular, severity of traction bronchiectasis and extent of honeycombing are superior to pulmonary function tests for predicting mortality in patients with CHP. (orig.)

  9. High-resolution computed tomography findings in chronic eosinophilic vs. cryptogenic organising pneumonia.

    Science.gov (United States)

    Mehrian, P; Doroudinia, A; Rashti, A; Aloosh, O; Dorudinia, A

    2017-11-01

    The similar clinical and computed tomography (CT) characteristics of cryptogenic organising pneumonia (COP) and chronic eosinophilic pneumonia (CEP) make precise diagnosis challenging. To help differentiate between COP and CEP using high-resolution CT (HRCT). Clinical data and HRCT images of COP and CEP patients referred to Masih Daneshvari Hospital, Tehran, Iran, from 2007 to 2015 were reviewed. Diagnosis of COP or CEP was confirmed using open lung biopsy or a combination of transbronchial biopsy, bronchoalveolar lavage fluid (BALF) analysis, peripheral eosinophilia and a favourable response to corticosteroids. Ground-glass opacity, a dominant ground-glass pattern, upper-lobe pneumonia, increased thickness of bronchial walls and a mosaic pattern in the lungs were more frequent in CEP. Lower-lobe pneumonia, subpleural reticulation, a dominant consolidation pattern, nodules and masses, non-septal linear opacities, bronchial dilation and a reverse halo sign were more frequent in COP. History of asthma, wheezing and peripheral eosinophilia was significantly more common in CEP than in COP. Distinguishing between CEP and COP based on HRCT alone is not always possible. However, in many cases, especially if the correct diagnosis cannot be established by other means, certain HRCT features can be very helpful.

  10. Hygromorphic characterization of softwood under high resolution X-ray tomography for hygrothermal simulation

    Science.gov (United States)

    El Hachem, Chady; Abahri, Kamilia; Vicente, Jérôme; Bennacer, Rachid; Belarbi, Rafik

    2018-03-01

    Because of their complex hygromorphic shape, microstructural study of wooden materials behavior has recently been the point of interest of researchers. The purpose of this study, in a first part, consists in characterizing by high resolution X-ray tomography the microstructural properties of spruce wood. In a second part, the subresulting geometrical parameters will be incorporated when evaluating the wooden hygrothermal transfers behavior. To do so, volume reconstructions of 3 Dimensional images (3D), obtained with a voxel size of 0.5 μm were achieved. The post-treatment of the corresponding volumes has given access to averages and standard deviations of lumens' diameters and cell walls' thicknesses. These results were performed for both early wood and latewood. Further, a segmentation approach for individualizing wood lumens was developed, which presents an important challenge in understanding localized physical properties. In this context, 3D heat and mass transfers within the real reconstructed geometries took place in order to highlight the effect of wood directions on the equivalent conductivity and moisture diffusion coefficients. Results confirm that the softwood cellular structure has a critical impact on the reliability of the studied physical parameters.

  11. Bronchiolitis obliterans following exposure to sulfur mustard: chest high resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ghanei, Mostafa E-mail: m.ghanei@bmsu.ac.ir; Mokhtari, Majid; Mohammad, Mehdi Mir; Aslani, Jafar

    2004-11-01

    Background: Pulmonary complications are known to occur in over half of the patients exposed to sulfur mustard (SM). Chemical weapons of mass destruction (WMD) including SM were used by Iraq during Iran-Iraq war between 1983 and 1989. We undertook this study to evaluate the chest high resolution computerized tomography (HRCT) as a diagnostic tool in patients with documented exposure to SM and chronic respiratory symptoms. Method: The medical records of 155 patients exposed to SM during Iran-Iraq war and suffered respiratory complications were reviewed. Chest HRCTs of these patients were examined. Ten healthy controls with no history of exposure to HD were matched for age, gender, and chest HRCT protocol applied. Results: Fifty chest HRCTs of these patients were randomly selected for this study. The most frequent findings were; air trapping 38 (76%), bronchiectasis 37 (74%), mosaic parenchymal attenuation (MPA) 36 (72%), irregular and dilated major airways 33 (66%) bronchial wall thickening (BWT) 45 (90%), and interlobular septal wall thickening (SWT) 13 (26%), respectively. Air trapping in one patient (10%) was the only positive finding in the control group. Conclusions: Chest HRCT findings of bronchiectasis, air trapping, MPA, SWT, and BWT were seen in our patients 15 years after exposure to HD. These findings suggest the diagnosis of bronchiolitis obliterans (BO). We did not encounter chest HRCT features consistent with pulmonary fibrosis.

  12. X-ray phase-contrast tomography for high-spatial-resolution zebrafish muscle imaging

    Science.gov (United States)

    Vågberg, William; Larsson, Daniel H.; Li, Mei; Arner, Anders; Hertz, Hans M.

    2015-11-01

    Imaging of muscular structure with cellular or subcellular detail in whole-body animal models is of key importance for understanding muscular disease and assessing interventions. Classical histological methods for high-resolution imaging methods require excision, fixation and staining. Here we show that the three-dimensional muscular structure of unstained whole zebrafish can be imaged with sub-5 μm detail with X-ray phase-contrast tomography. Our method relies on a laboratory propagation-based phase-contrast system tailored for detection of low-contrast 4-6 μm subcellular myofibrils. The method is demonstrated on 20 days post fertilization zebrafish larvae and comparative histology confirms that we resolve individual myofibrils in the whole-body animal. X-ray imaging of healthy zebrafish show the expected structured muscle pattern while specimen with a dystrophin deficiency (sapje) displays an unstructured pattern, typical of Duchenne muscular dystrophy. The method opens up for whole-body imaging with sub-cellular detail also of other types of soft tissue and in different animal models.

  13. TH-AB-209-07: High Resolution X-Ray-Induced Acoustic Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Xiang, L; Tang, S [University of Oklahoma, Norman, OK (United States); Ahmad, M [Stanford University, Palo Alto, CA (United States); Xing, L [Stanford University School of Medicine, Stanford, CA (United States)

    2016-06-15

    Purpose: X-ray radiographic absorption imaging is an invaluable tool in medical diagnostics, biology and materials science. However, the use of conventional CT is limited by two factors: the detection sensitivity to weak absorption material and the radiation dose from CT scanning. The purpose of this study is to explore X-ray induced acoustic computed tomography (XACT), a new imaging modality, which combines X-ray absorption contrast and high ultrasonic resolution to address these challenges. Methods: First, theoretical models was built to analyze the XACT sensitivity to X-ray absorption and calculate the minimal radiation dose in XACT imaging. Then, an XACT system comprised of an ultrashort X-ray pulse, a low noise ultrasound detector and a signal acquisition system was built to evaluate the X-ray induced acoustic signal generation. A piece of chicken bone and a phantom with two golden fiducial markers were exposed to 270 kVp X-ray source with 60 ns exposure time, and the X-ray induced acoustic signal was received by a 2.25MHz ultrasound transducer in 200 positions. XACT images were reconstructed by a filtered back-projection algorithm. Results: The theoretical analysis shows that X-ray induced acoustic signals have 100% relative sensitivity to X-ray absorption, but not to X-ray scattering. Applying this innovative technology to breast imaging, we can reduce radiation dose by a factor of 50 compared with newly FDA approved breast CT. The reconstructed images of chicken bone and golden fiducial marker phantom reveal that the spatial resolution of the built XACT system is 350µm. Conclusion: In XACT, the imaging sensitivity to X-ray absorption is improved and the imaging dose is dramatically reduced by using ultrashort pulsed X-ray. Taking advantage of the high ultrasonic resolution, we can also perform 3D imaging with a single X-ray pulse. This new modality has the potential to revolutionize x-ray imaging applications in medicine and biology.

  14. High resolution electrical resistivity tomography of golf course greens irrigated with reclaimed wastewater: Hydrological approach

    Science.gov (United States)

    Tapias, Josefina C.; Lovera, Raúl; Himi, Mahjoub; Gallardo, Helena; Sendrós, Alexandre; Marguí, Eva; Queralt, Ignasi; Casas, Albert

    2014-05-01

    tomography is a non-invasive and cost-effective technique for high resolution characterizing the subsurface below golf course greens. The obtained models have provided detailed information on the lateral and vertical variability of each the subsurface and from an empirical correlation between the values of electrical resistivity and hydraulic permeability to assess the preferred areas of drainage that could pose in risk to the vulnerability of the underlying aquifers.

  15. PATTERN OF INTERSTITIAL LUNG DISEASE AS SEEN BY HIGH RESOLUTION COMPUTERISED TOMOGRAPHY.

    Science.gov (United States)

    Onyambu, C K; Waigwa, M N

    2012-09-01

    Diffuse lung diseases constitute a major cause of morbidity and mortality worldwide. High Resolution Computed Tomography (HRCT) is the recommended imaging technique in the diagnosis, assessment and followup of these diseases. To describe the pattern of HRCT findings in patients with suspected interstitial lung disease. Kenyatta National Hospital (KNH), Nairobi Hospital and MP Shah Hospital; all situated in Nairobi, during the period February to August 2010. One hundred and one patients sent for HRCT in the six month study period. A total of 101 patients were recruited with age range 18 to 100 years, with a mean age of 53.6 (SD 19.7) years and a median age of 54 years. The male-female ratio was 1.2:1. Cough [80.2% (n = 81)] was the most common presenting complaint followed by dyspnoea (53.5%, n = 53) and chest pain [24.8% (n = 25)]. Overall, the predominant pattern of involvement on chest HRCT was reticular pattern seen in 56.1% (n = 82) of patients, followed by honey-comb pattern (37.8%, n = 82). The study demonstrated marked lung parenchymal destruction in most cases; a poor prognostic indicator which could have been due to delayed referral. HRCT has a high pick up rate of subtle parenchymal lung lesions as well as defining the lesions and their distribution compared to plain chest radiography. This is important in narrowing the differential diagnosis as well as for pre-biopsy planning. The diagnosis of ILD requires a multidisciplinary approach including a detailed clinical history, physical findings, and laboratory investigations, radiological and histological assessment.

  16. High resolution seismic tomography imaging of Ireland with quarry blast data

    Science.gov (United States)

    Arroucau, P.; Lebedev, S.; Bean, C. J.; Grannell, J.

    2017-12-01

    Local earthquake tomography is a well established tool to image geological structure at depth. That technique, however, is difficult to apply in slowly deforming regions, where local earthquakes are typically rare and of small magnitude, resulting in sparse data sampling. The natural earthquake seismicity of Ireland is very low. That due to quarry and mining blasts, on the other hand, is high and homogeneously distributed. As a consequence, and thanks to the dense and nearly uniform coverage achieved in the past ten years by temporary and permanent broadband seismological stations, the quarry blasts offer an alternative approach for high resolution seismic imaging of the crust and uppermost mantle beneath Ireland. We detected about 1,500 quarry blasts in Ireland and Northern Ireland between 2011 and 2014, for which we manually picked more than 15,000 P- and 20,000 S-wave first arrival times. The anthropogenic, explosive origin of those events was unambiguously assessed based on location, occurrence time and waveform characteristics. Here, we present a preliminary 3D tomographic model obtained from the inversion of 3,800 P-wave arrival times associated with a subset of 500 events observed in 2011, using FMTOMO tomographic code. Forward modeling is performed with the Fast Marching Method (FMM) and the inverse problem is solved iteratively using a gradient-based subspace inversion scheme after careful selection of damping and smoothing regularization parameters. The results illuminate the geological structure of Ireland from deposit to crustal scale in unprecedented detail, as demonstrated by sensitivity analysis, source relocation with the 3D velocity model and comparisons with surface geology.

  17. Initial characterization of a BGO-photodiode detector for high resolution positron emission tomography

    International Nuclear Information System (INIS)

    Derenzo, S.E.

    1983-11-01

    Spatial resolution in positron emission tomography is currently limited by the resolution of the detectors. This work presents the initial characterization of a detector design using small bismuth germanate (BGO) crystals individually coupled to silicon photodiodes (SPDs) for crystal identification, and coupled in groups to phototubes (PMTs) for coincidence timing. A 3 mm x 3 mm x 3 mm BGO crystal coupled only to an SPD can achieve a 511 keV photopeak resolution of 8.7% FWHM at -150 0 C, using a pulse peaking time of 10 μs. When two 3 mm x 3 mm x 15 mm BGO crystals are coupled individually to SPDs and also coupled to a common 14 mm diam PMT, the SPDs detect the 511 keV photopeak with a resolution of 30% FWHM at -76 0 C. In coincidence with an opposing 3 mm wide BGO crystal, the SPDs are able to identify the crystal of interaction with good signal-to-noise ratio, and the detector pair resolution is 2 mm FWHM. 32 references, 7 figures, 3 tables

  18. Evaluation of pulmonary changes due to biomass fuels using high-resolution computed tomography

    International Nuclear Information System (INIS)

    Kara, Mustafa; Tas, Fikret; Bulut, Sema; Akkurt, Ibrahim; Seyfikli, Zehra

    2003-01-01

    Biomass fuels are frequently used in rural areas of the world for cooking and heating frequently. It has been reported that the use of these fuels causes hazardous effects on the lungs. In this study, we evaluated the pulmonary changes due to the use of biomass fuels in a female population that lives in our territory by high-resolution computed tomography (HRCT). The study analyzed three groups of women. The first group comprised those subjects who were exposed to biomass without respiratory symptoms (group 1; n=32). The second group comprised those individuals that were exposed to biomass and showed respiratory symptoms, such as cough, sputum production, and dyspnea (group 2; n=30). The third group was composed of women who were not exposed to biomass and also had no respiratory symptoms (group 3; n=30). Women with a history of concomitant pulmonary diseases were excluded from the study. All groups were examined with HRCT. Groups 1 and 2 (individuals exposed to biomass fuels) had more pathologic findings than group 3 (not exposed to biomass fuels). Ground-glass appearance was seen in 71.9% in group 1, 23.3% in group 2, and 3.3% in group 3. The difference between the groups was statistically significant (p<0.05). Fibrotic bands were seen 50% in group 1, 63.3% in group 2, and only 6.7% in group 3 (p<0.001). Exposure to biomass fuels was the cause or predisposing factor for many pulmonary diseases, ranging from chronic bronchitis to diffuse lung diseases. We believe that these pathological changes due to biomass fuels can be detected earlier by HRCT and the diseases might be prevented or treated earlier. (orig.)

  19. Radiologist agreement on the quantification of bronchiectasis by high-resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brito, Milene Carneiro Barbosa de, E-mail: milenebrito7@gmail.com [Clinica da Imagem do Tocantins, Araguaia, TO (Brazil); Ota, Mauricio Kenji [Fundacao Instituto de Pesquisa e Estudos de Diagnostico por Imagem (FIDI), Sao Paulo, SP (Brazil); Leitao Filho, Fernando Sergio Studart [Universidade de Fortaleza (UNIFOR), Fortaleza, CE (Brazil); Meirelles, Gustavo de Souza Portes [Grupo Fleury, Sao Paulo, SP (Brazil)

    2017-01-15

    Objective: To evaluate radiologist agreement on the quantification of bronchiectasis by high-resolution computed tomography (HRCT). Materials and Methods: The HRCT scans of 43 patients with bronchiectasis were analyzed by two radiologists, who used a scoring system to grade the findings. Kappa (κ) values and overall agreement were calculated. Results: For the measurement and appearance of bronchiectasis, the interobserver agreement was moderate (κ = 0.45 and κ = 0.43, respectively), as was the intraobserver agreement (κ = 0.54 and κ = 0.47, respectively). Agreement on the presence of mucous plugging was fair, for central distribution (overall interobserver agreement of 68.3% and κ = 0.39 for intraobserver agreement) and for peripheral distribution (κ = 0.34 and κ = 0.35 for interobserver and intraobserver agreement, respectively). The agreement was also fair for peri bronchial thickening (κ = 0.21 and κ = 0.30 for interobserver and intraobserver agreement, respectively). There was fair interobserver and intraobserver agreement on the detection of opacities (κ = 0.39 and 71.9%, respectively), ground-glass attenuation (64.3% and κ = 0.24, respectively), and cysts/bullae (κ = 0.47 and κ = 0.44, respectively). Qualitative analysis of the HRCT findings of bronchiectasis and the resulting individual patient scores showed that there was an excellent correlation between the observers (intra class correlation coefficient of 0.85 and 0.81 for interobserver and intraobserver agreement, respectively). Conclusion: In the interpretation of HRCT findings of bronchiectasis, radiologist agreement appears to be fair. In our final analysis of the findings using the proposed score, we observed excellent interobserver and intraobserver agreement. (author)

  20. Radiologist agreement on the quantification of bronchiectasis by high-resolution computed tomography

    International Nuclear Information System (INIS)

    Brito, Milene Carneiro Barbosa de; Ota, Mauricio Kenji; Leitao Filho, Fernando Sergio Studart; Meirelles, Gustavo de Souza Portes

    2017-01-01

    Objective: To evaluate radiologist agreement on the quantification of bronchiectasis by high-resolution computed tomography (HRCT). Materials and Methods: The HRCT scans of 43 patients with bronchiectasis were analyzed by two radiologists, who used a scoring system to grade the findings. Kappa (κ) values and overall agreement were calculated. Results: For the measurement and appearance of bronchiectasis, the interobserver agreement was moderate (κ = 0.45 and κ = 0.43, respectively), as was the intraobserver agreement (κ = 0.54 and κ = 0.47, respectively). Agreement on the presence of mucous plugging was fair, for central distribution (overall interobserver agreement of 68.3% and κ = 0.39 for intraobserver agreement) and for peripheral distribution (κ = 0.34 and κ = 0.35 for interobserver and intraobserver agreement, respectively). The agreement was also fair for peri bronchial thickening (κ = 0.21 and κ = 0.30 for interobserver and intraobserver agreement, respectively). There was fair interobserver and intraobserver agreement on the detection of opacities (κ = 0.39 and 71.9%, respectively), ground-glass attenuation (64.3% and κ = 0.24, respectively), and cysts/bullae (κ = 0.47 and κ = 0.44, respectively). Qualitative analysis of the HRCT findings of bronchiectasis and the resulting individual patient scores showed that there was an excellent correlation between the observers (intra class correlation coefficient of 0.85 and 0.81 for interobserver and intraobserver agreement, respectively). Conclusion: In the interpretation of HRCT findings of bronchiectasis, radiologist agreement appears to be fair. In our final analysis of the findings using the proposed score, we observed excellent interobserver and intraobserver agreement. (author)

  1. High-resolution computed tomography findings in elderly patients with asthma

    International Nuclear Information System (INIS)

    Yilmaz, Sevda; Ekici, Aydanur; Ekici, Mehmet; Keles, Hatice

    2006-01-01

    Objective: Based on the hypothesis that airway remodelling is related to the duration of asthma, HRCT scanning should show greater abnormalities in the early-onset than the late-onset asthmatics. It was, therefore, intended to assess the presence and the frequency of airway and parenchymal abnormalities with high-resolution computed tomography (HRCT) in elderly asthmatic patients, and to determine whether these abnormalities are related to the duration of asthma. Patients and methods: Sixty-eight clinically stable asthmatic patients aged ≥60 yr were included in this prospective study. The patients were separated into two groups according to the duration of symptoms as late-onset asthma (n = 31) with disease duration of <5 yr, and early-onset asthma (n = 37) with disease duration of ≥5 yr. All patients were lifelong non-smoker and had been using inhaled beta agonists and inhaled steroids. HRCT-scanning and histamine inhalation test were performed on all patients. Results: In comparison with late-onset asthmatic patients, those with early-onset asthma had significantly higher frequency of emphysema (21.6% versus 0.0%, p = 0.006), bronchial dilatation (13.9% versus 0.0%, p 0.03) and bronchial wall thickness (41.7% versus 12.9%, p = 0.01). Multiple logistic regression analysis identified that early-onset of disease was an independent risk factor for the presence of irreversible HRCT-scan abnormalities in elderly asthmatics [odds ratio (OR): 9.4 (2.7-32.7), p 0.00001]. Conclusion: Present data suggest that HRCT abnormalities in early-onset elderly asthmatics reflect parenchymal and airway changes that become irreversible throughout the long course of the disease

  2. Determination of the activity of pulmonary tuberculosis : the utility of high-resolution computed tomography

    International Nuclear Information System (INIS)

    Chung, Myung Hee; Lee, Hae Giu; Yu, Won Jong; Chung, Hong Jun; Yang, Bo Sung; Kwon, Soon Suck; Park, Seog Hee

    2000-01-01

    To evaluate the utility of high-resolution computed tomography (HRCT), as used to determine the activity of tuberculosis, and to analyze the HRCT findings in active and in inactive tuberculosis. We analyzed the HRCT findings of 100 patients (54 men, 46 women; average age, 54 years) who according to the results of chest radiography had pulmonary tuberculosis of undetermined activity. We assessed HRCT findings such as the presence of a centrilobular, macro-, or micronodule; consolidation, ground-glass opacity, cavity, interlobular septal thickening, irregular linear opacities, bronchial wall thickening, bronchovascular bundle distortion, bronchiectasis, atelectasis, and pericicatrical emphysema. We compared the ratio of the area of nodule and consolidation to that of whole lung, and compared the findings between active and inactive tuberculosis. Eleven of 100 patients were excluded because the final diagnosis was other than tuberculosis. In 59 patients, the presence of active pulmonary tuberculosis was proven by positive sputum smear and/or culture for mycobacterium tuberculosis. On the basis of the negative results of these tests, pulmonary tuberculosis was found to be inactive in 30 patients; serial chest radiographs indicated that their condition remained stable over a 6-month period. For HRCT, sensitivity was 96.6%, specificity 56.7%, positive predictive value 81.4%, negative predictive value 89.5%, and accuracy 83.1%. For active tuberculosis, the presence of centrilobular nodules, tree-in-bud, macronodules, cavity within the nodule, and consolidations was statistically significant, while for inactive tuberculosis, that of irregular linear opacities, micronodules, bronchiectasis, and cicatrization atectasis was similarly significant. The CT score for the area of nodules and consolidations was higher in active than in inactive tuberculosis, but only the nodule score showed statistical significance. HRCT can be a useful diagnostic tool for evaluating the activity

  3. The subclinical involvement of the lung in rheumatoid arthritis: evaluation by high-resolution computed tomography

    Directory of Open Access Journals (Sweden)

    E. Bichi Secchi

    2011-09-01

    Full Text Available Pulmonary involvement is one of the most frequent extra-articular manifestations of rheumatoid arthritis (RA and represents a serious complication, being the second cause of death after infection. High-resolution computed tomography (HRCT, owing to its increased sensitivity and diagnostic accuracy respect to the conventional chest radiograph (CXR, allows to detect pulmonary abnormalities in RA patients more frequently than CXR. The aim of this study was to assess pulmonary involvement by HRCT in lifelong non-smoking RA patients without symptoms and clinical signs of pulmonary disease. Seventy-two patients (54 women and 18 men with a mean age of 56.8±10.4 years (range, 40- 77 years and mean duration of disease of 6.9±4.7 years (range, 2-12 years entered the study. 52/72 (72% were positive for rheumatoid factor (> 20 UI/ml. Standard CXR and HRCT were carried out in each patient. CXR showed a mild interstitial fibrosis in 7 patients (9.7%, whereas HRCT demonstrated pulmonary abnormalities in an higher number of them (22/72 = 30.5%. The most frequent abnormal findings on HRCT were irregular pleural margins (13.8% and septal/subpleural lines (18%, both compatible with pulmonary fibrosis. Ground-glass opacities were found in 8.3% of the patients. Pulmonary nodules (diameter, range 0,5-2 cm predominantly located in the subpleural portions of the lung, were demonstrated in the same percentage (8.3% of patients. Small airway involvement, represented by bronchiectasis/bronchioloectasis, was shown in 15.2% of patients. Subpleural cysts were present in two cases (2.8%. No patient had evidence of honeycombing on HRCT. In conclusion, HRCT is an accurate, non-invasive and safe method of diagnosing lung abnormalities in RA patients without signs and clinical symptoms of pulmonary disease...

  4. Quantitative image analysis of vertebral body architecture - improved diagnosis in osteoporosis based on high-resolution computed tomography

    International Nuclear Information System (INIS)

    Mundinger, A.; Wiesmeier, B.; Dinkel, E.; Helwig, A.; Beck, A.; Schulte Moenting, J.

    1993-01-01

    71 women, 64 post-menopausal, were examined by single-energy quantitative computed tomography (SEQCT) and by high-resolution computed tomography (HRCT) scans through the middle of lumbar vertebral bodies. Computer-assisted image analysis of the high-resolution images assessed trabecular morphometry of the vertebral spongiosa texture. Texture parameters differed in women with and without age-reduced bone density, and in the former group also in patients with and without vertebral fractures. Discriminating parameters were the total number, diameter and variance of trabecular and intertrabecular spaces as well as the trabecular surface (p < 0.05)). A texture index based on these statistically selected morphometric parameters identified a subgroup of patients suffering from fractures due to abnormal spongiosal architecture but with a bone mineral content not indicative for increased fracture risk. The combination of osteodensitometric and trabecular morphometry improves the diagnosis of osteoporosis and may contribute to the prediction of individual fracture risk. (author)

  5. High resolution propagation-based imaging system for in vivo dynamic computed tomography of lungs in small animals

    Science.gov (United States)

    Preissner, M.; Murrie, R. P.; Pinar, I.; Werdiger, F.; Carnibella, R. P.; Zosky, G. R.; Fouras, A.; Dubsky, S.

    2018-04-01

    We have developed an x-ray imaging system for in vivo four-dimensional computed tomography (4DCT) of small animals for pre-clinical lung investigations. Our customized laboratory facility is capable of high resolution in vivo imaging at high frame rates. Characterization using phantoms demonstrate a spatial resolution of slightly below 50 μm at imaging rates of 30 Hz, and the ability to quantify material density differences of at least 3%. We benchmark our system against existing small animal pre-clinical CT scanners using a quality factor that combines spatial resolution, image noise, dose and scan time. In vivo 4DCT images obtained on our system demonstrate resolution of important features such as blood vessels and small airways, of which the smallest discernible were measured as 55–60 μm in cross section. Quantitative analysis of the images demonstrate regional differences in ventilation between injured and healthy lungs.

  6. High resolution neutron tomography applied to tooth fillings on real teeth by use of neutron lens

    International Nuclear Information System (INIS)

    Masschaele, B.; Cauwels, P.; Mondelaers, W.; Baechler, S.; Jolie, J.; Materna, T.

    2000-01-01

    Today tomography is a well known technique for nondestructive analysis of samples. By taking several X-ray pictures from an object, it is possible to make a 3D reconstruction. The same thing can be done with neutrons. Since very recent it is possible to produce a high-flux neutron beam. By looking at the attenuation of the neutron beam in the sample from different angles, it is possible to make a neutron tomography. The properties of neutrons are so much different from X-rays that a new era in tomography has started. Where X-rays have a hard time penetrating samples containing heavy elements (Pb, Bi, U, Hg, Au), neutrons just seem to walk through. But when the neutrons encounter samples containing light compounds like water, oil, paper, B, Li,... they are easily absorbed. This makes the use of neutrons for imaging complementary to the well known X-ray imaging. The most used tooth filling material nowadays is amalgam. Amalgam is a mixture of different metals, like silver, tin, copper, mercury. Mercury is dangerous for the human body when it enters the blood stream. These fillings are very dense and X-rays have a very hard time penetrating it. Neutrons are the ideal probe for investigation of these high density regions. The result of the tomography reveals information on the long term stability of amalgam fillings and could help the still ongoing debate on the safety of the fillings. (author)

  7. High-resolution-cone beam tomography analysis of bone microarchitecture in patients with acromegaly and radiological vertebral fractures.

    Science.gov (United States)

    Maffezzoni, Filippo; Maddalo, Michele; Frara, Stefano; Mezzone, Monica; Zorza, Ivan; Baruffaldi, Fabio; Doglietto, Francesco; Mazziotti, Gherardo; Maroldi, Roberto; Giustina, Andrea

    2016-11-01

    Vertebral fractures are an emerging complication of acromegaly but their prediction is still difficult occurring even in patients with normal bone mineral density. In this study we evaluated the ability of high-resolution cone-beam computed tomography to provide information on skeletal abnormalities associated with vertebral fractures in acromegaly. 40 patients (24 females, 16 males; median age 57 years, range 25-72) and 21 healthy volunteers (10 females, 11 males; median age 60 years, range: 25-68) were evaluated for trabecular (bone volume/trabecular volume ratio, mean trabecular separation, and mean trabecular thickness) and cortical (thickness and porosity) parameters at distal radius using a high-resolution cone-beam computed tomography system. All acromegaly patients were evaluated for morphometric vertebral fractures and for mineral bone density by dual-energy X-ray absorptiometry at lumbar spine, total hip, femoral neck, and distal radius. Acromegaly patients with vertebral fractures (15 cases) had significantly (p acromegaly patients did not have significant differences in bone density at either skeletal site. Patients with acromegaly showed lower bone volume/trabecular volume ratio (p = 0.003) and mean trabecular thickness (p acromegaly. High-resolution cone-beam computed tomography at the distal radius may be useful to evaluate and predict the effects of acromegaly on bone microstructure.

  8. Progressive systemic sclerosis: high-resolution computed tomography findings; Esclerose sistemica progressiva: aspectos na tomografia computadorizada de alta resolucao

    Energy Technology Data Exchange (ETDEWEB)

    Gasparetto, Emerson L.; Pimenta, Rodrigo; Ono, Sergio E.; Escuissato, Dante L. [Parana Univ., Curitiba, PR (Brazil). Hospital de Clinicas. Servico de Radiologia Medica]. E-mail: dante.luiz@onda.com.br; Inoue, Cesar [Parana Univ., Curitiba, PR (Brazil). Faculdade de Medicina

    2005-09-15

    Objective: To describe the high-resolution computed tomography findings in the lung of patients with systemic sclerosis, independently of the respiratory symptoms. Materials and methods: Seventy-three high-resolution computed tomography scans of 44 patients with clinical diagnosis of systemic sclerosis were reviewed and defined by the consensus of two radiologists. Results: Abnormalities were seen in 91.8% (n = 67) of the scans. The most frequent findings were reticular pattern (90.4%), ground-glass opacities (63%), traction bronchiectasis and bronchiolectasis (56.2%), esophageal dilatation (46.6%), honeycombing pattern (28.8%) and signs of pulmonary hypertension (15.6%). In most cases the lesions were bilateral (89%) and symmetrical (58.5%). The lesions were predominantly located in the basal (91.2%) and peripheral (92.2%) regions. Conclusion: In the majority of the patients, progressive systemic sclerosis can cause pulmonary fibrosis mainly characterized by reticular pattern with basal and peripheral distribution on high-resolution computed tomography. (author)

  9. Ultra-High Resolution Optical Coherence Tomography Imaging of Unilateral Drusen in a 31 Year Old Woman.

    Science.gov (United States)

    de Carlo, Talisa E; Adhi, Mehreen; Lu, Chen D; Duker, Jay S; Fujimoto, James G; Waheed, Nadia K

    We report a case of widespread unilateral drusen in a healthy 31 year old Caucasian woman using multi-modal imaging including ultra-high resolution optical coherence tomography (UHR-OCT). Dilated fundus exam showed multiple drusen-like lesions in the posterior pole without heme or fluid. Fundus auto fluorescence demonstrated hyperautofluorescent at the deposits. Fluorescein angiography revealed mild hyperfluorescence and staining of the lesions. Spectral-domain optical coherence tomography (SD-OCT) OS showed accumulations in the temporal macula at Bruch's membrane. UHR-OCT provided improved axial resolution compared to the standard 5 μm on the commercial SD-OCT and confirmed the presence of deposits in Bruch's membrane, consistent with drusen. The retinal layers were draped over the excrescences but did not show any disruption.

  10. High-resolution computed tomography of the temporal bone. Part 2.: pathology

    International Nuclear Information System (INIS)

    Grzegorzewski, M.; Boron, Z.; Burzynska-Makuch, M.

    1995-01-01

    Selected cases of the temporal bone pathology on high resolution CT were demonstrated. Transverse and coronal sections of the cases were selected from 68 patients with various otological diseases. (author)

  11. Comparison of high resolution computed tomography and pulmonary function tests in diagnosis of mild emphysema

    International Nuclear Information System (INIS)

    Kuwano, Kazuyoshi; Matsuba, Kenichi; Ikeda, Togo

    1989-01-01

    To assess the ability of high resolution CT scan and pulmonary function tests in detecting and grading mild emphysema, we correlated the high resolution CT scan and pulmonary function tests with the pathologic grade of emphysema and the destructive index of lung specimens from 42 patients undergoing thoracotomy for solitary pulmonary nodules. Using the high resolution CT scan, we could identify the pathologic grade of mild and moderate emphysema. By measuring diffusing capacity per unit alveolar gas volume (DLco/VA), it seemed to be possible to detect the mildest degree of alveolar destruction assessed by the destructive index, which was not detected by high resolution CT scan. The reason for these results seemed to be that we assessed the severity of emphysema by detecting the air space enlargement on high resolution CT scan images caused by the destruction of alveolar walls, which were detectable by measuring DLco/VA. We conclude that it is possible to detect mild emphysema using the combination of high resolution CT scan and pulmomary function tests. (author)

  12. Interstitial lung illness: Discoveries in x-ray of the thorax vs computerized tomography of high resolution

    International Nuclear Information System (INIS)

    Patino O, Maria Olga; Gomez Ramirez, Rafael

    1993-01-01

    This study wants to prove the advantages of the computerized axial tomography (TAC) of high resolution on the conventional radiography and the follow-up of the patients with interstitial pulmonary disease (IPD). 29 patients were studied with conventional RX and TAC with 17. $ % of high resolution which had normal radiography with clear abnormalities in the TAC of high resolution, the type of interstitial pulmonary disease (IPD). In the 68,9% of the cases it showed abnormality as well in TAC as in conventional RX. In the fact, that the TAC does not allow a specific etiologic diagnosis of the IPD type, as it is done in the biopsy. It allows identifying abnormality in those patients apparently normal by the radiography of the thorax and when it already exists the histopathologic diagnosis it allows the follow-up in a no invasive way

  13. Spirometry-Assisted High Resolution Chest Computed Tomography in Children: Is it Worth the Effort?

    Science.gov (United States)

    Otjen, Jeffrey Parke; Swanson, Jonathan Ogden; Oron, Assaf; DiBlasi, Robert M; Swortzel, Tim; van Well, Jade Adriana Marie; Gommers, Eva Anna Elisabeth; Rosenfeld, Margaret

    Image quality of high resolution chest computed tomographies (HRCTs) depends on adequate breath holds at end inspiration and end expiration. We hypothesized that implementation of spirometry-assisted breath holds in children undergoing HRCTs would improve image quality over that obtained with voluntary breath holds by decreasing motion artifact and atelectasis. This is a retrospective case-control study of HRCTs obtained at a tertiary care children's hospital before and after implementation of a spirometry-assisted CT protocol, in which children ≥8 years of age are first trained in supine slow vital capacity maneuvers and then repeat the maneuvers in the CT scanner, coached by a respiratory therapist. Spirometry-assisted CT scans (cases) were matched by age, gender and diagnosis (cystic fibrosis vs other) to CT scans obtained with voluntary breath holds in the 6 years before implementation of the spirometry assistance protocol (controls), and evaluated by 2 blinded pediatric radiologists. Among both cases and controls (N = 50 each), 10 carried the diagnosis of cystic fibrosis and 40 had other diagnoses. Mean age was 12.9 years (range: 7.5-20.1) among cases and 13.0 (7.1-19.7) among controls. Mean (SD) inspiratory image density among cases was -852 (37) Hounsfield units (HU) and -828 (43) among controls (p = 0.006). Mean (SD) expiratory image density was -629 (95) HU among cases and -688 (83) HU among controls (p = 0.002). Mean (SD) change in image density between inspiratory and expiratory images was +222 (85) HU among cases and +140 (76) HU among controls (p 0.80). Atelectasis was present on inspiratory images in 8 cases and 9 controls and on expiratory images in 9 cases and 10 controls (p > 0.80). Spirometry-assisted CTs had a significantly greater difference in lung density between inspiratory and expiratory scans than those performed with voluntary breath holds, likely improving the ability to detect air trapping. No appreciable difference in image quality

  14. The micro-mechanics of strength, durability and damage tolerance in composites: new insights from high resolution computed tomography

    Science.gov (United States)

    Spearing, S. Mark; Sinclair, Ian

    2016-07-01

    Recent work, led by the authors, on impact damage resistance, particle toughening and tensile fibre failure is reviewed in order to illustrate the use of high-resolution X-ray tomography to observe and quantify damage mechanisms in carbon fibre composite laminates. Using synchrotron and micro-focus X-ray sources resolutions of less than 1 μm have been routinely achieved. This enables individual broken fibres and the micromechanisms of particle toughening to be observed and quantified. The data for fibre failure, cluster formation and overall tensile strength are compared with model predictions. This allows strategies for future model development to be identified. The overall implications for using such high-resolution 3-D measurements to inform a “data-rich mechanics” approach to materials evaluation and modeling is discussed.

  15. High-resolution breast tomography at high energy: a feasibility study of phase contrast imaging on a whole breast

    International Nuclear Information System (INIS)

    Sztrókay, A; Schlossbauer, T; Bamberg, F; Reiser, M F; Coan, P; Diemoz, P C; Brun, E; Bravin, A; Mayr, D

    2012-01-01

    Previous studies on phase contrast imaging (PCI) mammography have demonstrated an enhancement of breast morphology and cancerous tissue visualization compared to conventional imaging. We show here the first results of the PCI analyser-based imaging (ABI) in computed tomography (CT) mode on whole and large (>12 cm) tumour-bearing breast tissues. We demonstrate in this work the capability of the technique of working at high x-ray energies and producing high-contrast images of large and complex specimens. One entire breast of an 80-year-old woman with invasive ductal cancer was imaged using ABI-CT with monochromatic 70 keV x-rays and an area detector of 92×92 µm 2 pixel size. Sagittal slices were reconstructed from the acquired data, and compared to corresponding histological sections. Comparison with conventional absorption-based CT was also performed. Five blinded radiologists quantitatively evaluated the visual aspects of the ABI-CT images with respect to sharpness, soft tissue contrast, tissue boundaries and the discrimination of different structures/tissues. ABI-CT excellently depicted the entire 3D architecture of the breast volume by providing high-resolution and high-contrast images of the normal and cancerous breast tissues. These results are an important step in the evolution of PCI-CT towards its clinical implementation. (paper)

  16. High-resolution breast tomography at high energy: a feasibility study of phase contrast imaging on a whole breast

    Science.gov (United States)

    Sztrókay, A.; Diemoz, P. C.; Schlossbauer, T.; Brun, E.; Bamberg, F.; Mayr, D.; Reiser, M. F.; Bravin, A.; Coan, P.

    2012-05-01

    Previous studies on phase contrast imaging (PCI) mammography have demonstrated an enhancement of breast morphology and cancerous tissue visualization compared to conventional imaging. We show here the first results of the PCI analyser-based imaging (ABI) in computed tomography (CT) mode on whole and large (>12 cm) tumour-bearing breast tissues. We demonstrate in this work the capability of the technique of working at high x-ray energies and producing high-contrast images of large and complex specimens. One entire breast of an 80-year-old woman with invasive ductal cancer was imaged using ABI-CT with monochromatic 70 keV x-rays and an area detector of 92×92 µm2 pixel size. Sagittal slices were reconstructed from the acquired data, and compared to corresponding histological sections. Comparison with conventional absorption-based CT was also performed. Five blinded radiologists quantitatively evaluated the visual aspects of the ABI-CT images with respect to sharpness, soft tissue contrast, tissue boundaries and the discrimination of different structures/tissues. ABI-CT excellently depicted the entire 3D architecture of the breast volume by providing high-resolution and high-contrast images of the normal and cancerous breast tissues. These results are an important step in the evolution of PCI-CT towards its clinical implementation.

  17. Breaking the Crowther limit: Combining depth-sectioning and tilt tomography for high-resolution, wide-field 3D reconstructions

    Energy Technology Data Exchange (ETDEWEB)

    Hovden, Robert, E-mail: rmh244@cornell.edu [School of Applied and Engineering Physics and Kavli Institute at Cornell for Nanoscale Science, Cornell University, Ithaca, NY 14853 (United States); Ercius, Peter [National Center for Electron Microscopy, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Jiang, Yi [Department of Physics, Cornell University, Ithaca, NY 14853 (United States); Wang, Deli; Yu, Yingchao; Abruña, Héctor D. [Department of Chemistry and Chemical Biology, Cornell University, Ithaca, NY 14853 (United States); Elser, Veit [Department of Physics, Cornell University, Ithaca, NY 14853 (United States); Muller, David A. [School of Applied and Engineering Physics and Kavli Institute at Cornell for Nanoscale Science, Cornell University, Ithaca, NY 14853 (United States)

    2014-05-01

    To date, high-resolution (<1 nm) imaging of extended objects in three-dimensions (3D) has not been possible. A restriction known as the Crowther criterion forces a tradeoff between object size and resolution for 3D reconstructions by tomography. Further, the sub-Angstrom resolution of aberration-corrected electron microscopes is accompanied by a greatly diminished depth of field, causing regions of larger specimens (>6 nm) to appear blurred or missing. Here we demonstrate a three-dimensional imaging method that overcomes both these limits by combining through-focal depth sectioning and traditional tilt-series tomography to reconstruct extended objects, with high-resolution, in all three dimensions. The large convergence angle in aberration corrected instruments now becomes a benefit and not a hindrance to higher quality reconstructions. A through-focal reconstruction over a 390 nm 3D carbon support containing over 100 dealloyed and nanoporous PtCu catalyst particles revealed with sub-nanometer detail the extensive and connected interior pore structure that is created by the dealloying instability. - Highlights: • Develop tomography technique for high-resolution and large field of view. • We combine depth sectioning with traditional tilt tomography. • Through-focal tomography reduces tilts and improves resolution. • Through-focal tomography overcomes the fundamental Crowther limit. • Aberration-corrected becomes a benefit and not a hindrance for tomography.

  18. High-resolution computed tomography of the temporal bone. Part 1.: normal anatomy

    International Nuclear Information System (INIS)

    Grzegorzewski, M.; Boron, Z.; Burzynska-Makuch, M.

    1995-01-01

    Normal anatomy of the temporal bone in transverse and coronal sections was presented. CT studies were performed using high-resolution program. The images of an asymptomatic ear of 2 patients were selected from 68 cases examined on account of various otological diseases. All the sections showed as many as 68 anatomic structures. (author)

  19. The high-grade interpolator: a means for enhancing the resolution of helical computed tomography images of the lung

    International Nuclear Information System (INIS)

    Garcia-Santos, J. M.; Torres del rio, S.; Blanco, A.; Rodriguez, R.; Parlorio, E.; Garcia, A.; Girela, E.; Hernandez, M. D.; Canteras, M.

    2002-01-01

    The purpose of this study was to demonstrate that the use of a high-grade interpolator in the reconstruction of images of the chest increases the resolution, independently of the high-resolution filter. Eight independent observers in two groups (experts and non experts) assessed (two readings separated by a time interval) the same section of the chest reconstructed four times (st-st, st-xs, b-st, b-xs), combining standard (st) and high-resolution (b) filters and standard (st) and high-grade (xs) interpolators. The images were classified from greater to lesser in terms of the resolution perceived. The results were used to compare the degree of resolution introduced by the interpolator and the filter and to determine whether or not there existed variability between observers and between the observations of each, and whether experience played a role in the findings. Six of the eight observers assigned the b-xs images the highest degree of resolution in the majority of cases, followed by the b-st image, the st-xs image and, finally, the st-st image). The other tow observers (one expert and one nonexpert) different only with respect to the order of the st-xs and b-st images, which they assigned the second and third places, respectively. The expert group showed no intra observer variability, while two of the nonexpert observers did. The high-grade interpolator enhances the resolution of images of the chest regardless of who evaluates them, while it does not substantially increase image noise. Thus, its use is recommended in helical computed tomography imaging of the lung. (Author) 10 refs

  20. Development of high-resolution detector module with depth of interaction identification for positron emission tomography

    International Nuclear Information System (INIS)

    Niknejad, Tahereh; Pizzichemi, Marco; Stringhini, Gianluca; Auffray, Etiennette; Bugalho, Ricardo; Da Silva, Jose Carlos; Di Francesco, Agostino; Ferramacho, Luis; Lecoq, Paul; Leong, Carlos; Paganoni, Marco; Rolo, Manuel; Silva, Rui; Silveira, Miguel; Tavernier, Stefaan; Varela, Joao; Zorraquino, Carlos

    2017-01-01

    We have developed a Time-of-flight high resolution and commercially viable detector module for the application in small PET scanners. A new approach to depth of interaction (DOI) encoding with low complexity for a pixelated crystal array using a single side readout and 4-to-1 coupling between scintillators and photodetectors was investigated. In this method the DOI information is estimated using the light sharing technique. The detector module is a 1.53×1.53×15 mm"3 matrix of 8×8 LYSO scintillator with lateral surfaces optically depolished separated by reflective foils. The crystal array is optically coupled to 4×4 silicon photomultipliers (SiPM) array and readout by a high performance front-end ASIC with TDC capability (50 ps time binning). The results show an excellent crystal identification for all the scintillators in the matrix, a timing resolution of 530 ps, an average DOI resolution of 5.17 mm FWHM and an average energy resolution of 18.29% FWHM. - Highlights: • A new method for DOI encoding for PET detectors based on light sharing is proposed. • A prototype module with LYSO scintillator matrix coupled to SiPMs array is produced. • The module has one side readout and 4-to-1 coupling between scintillators and SiPMs. • A compact TOF front-end ASIC is used. • Excellent performances are shown by the prototype module.

  1. Development of high-resolution detector module with depth of interaction identification for positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Niknejad, Tahereh, E-mail: tniknejad@lip.pt [Laboratory of Instrumentation and Experimental Particles Physics, Lisbon (Portugal); Pizzichemi, Marco [University of Milano-Bicocca (Italy); Stringhini, Gianluca [University of Milano-Bicocca (Italy); CERN, Geneve (Switzerland); Auffray, Etiennette [CERN, Geneve (Switzerland); Bugalho, Ricardo; Da Silva, Jose Carlos; Di Francesco, Agostino [Laboratory of Instrumentation and Experimental Particles Physics, Lisbon (Portugal); Ferramacho, Luis [PETsys Electronics, Oeiras (Portugal); Lecoq, Paul [CERN, Geneve (Switzerland); Leong, Carlos [PETsys Electronics, Oeiras (Portugal); Paganoni, Marco [University of Milano-Bicocca (Italy); Rolo, Manuel [Laboratory of Instrumentation and Experimental Particles Physics, Lisbon (Portugal); INFN, Turin (Italy); Silva, Rui [Laboratory of Instrumentation and Experimental Particles Physics, Lisbon (Portugal); Silveira, Miguel [PETsys Electronics, Oeiras (Portugal); Tavernier, Stefaan [PETsys Electronics, Oeiras (Portugal); Vrije Universiteit Brussel (Belgium); Varela, Joao [Laboratory of Instrumentation and Experimental Particles Physics, Lisbon (Portugal); CERN, Geneve (Switzerland); Zorraquino, Carlos [Biomedical Image Technologies Lab, Universidad Politécnica de Madrid (Spain); CIBER-BBN, Universidad Politécnica de Madrid (Spain)

    2017-02-11

    We have developed a Time-of-flight high resolution and commercially viable detector module for the application in small PET scanners. A new approach to depth of interaction (DOI) encoding with low complexity for a pixelated crystal array using a single side readout and 4-to-1 coupling between scintillators and photodetectors was investigated. In this method the DOI information is estimated using the light sharing technique. The detector module is a 1.53×1.53×15 mm{sup 3} matrix of 8×8 LYSO scintillator with lateral surfaces optically depolished separated by reflective foils. The crystal array is optically coupled to 4×4 silicon photomultipliers (SiPM) array and readout by a high performance front-end ASIC with TDC capability (50 ps time binning). The results show an excellent crystal identification for all the scintillators in the matrix, a timing resolution of 530 ps, an average DOI resolution of 5.17 mm FWHM and an average energy resolution of 18.29% FWHM. - Highlights: • A new method for DOI encoding for PET detectors based on light sharing is proposed. • A prototype module with LYSO scintillator matrix coupled to SiPMs array is produced. • The module has one side readout and 4-to-1 coupling between scintillators and SiPMs. • A compact TOF front-end ASIC is used. • Excellent performances are shown by the prototype module.

  2. High-resolution computed tomography of the lung in smokers: Visual and computer-based analysis

    International Nuclear Information System (INIS)

    Mueller-Leisse, C.; Otto, A.; Berger, F.; Schmitz, E.; Guenther, R.W.

    1997-01-01

    Purpose: It has been the aim of the study to assess parenchymal changes in the lung with high-resolution CT in healthy heavy, moderate, and non-smokers. Material and methods: We prospectively evaluated CT changes in 42 healthy heavy smokers (gr. (group) 2, ≥30 pack-years), 40 moderate smokers (gr. 1, R , Kontron GmbH, Munich, Germany). Results: Productive cough, dyspnoea and chronic bronchitis were more common in smokers than in non-smokers (p [de

  3. High resolution 3-D shear wave velocity structure in South China from surface wave tomography

    Science.gov (United States)

    Ning, S.; Guo, Z.; Chen, Y. J.

    2017-12-01

    Using continuous data from a total of 638 seismic stations, including 484 from CEArray between 2008 and 2013 and 154 from SINOPROBE between 2014 and 2015, we perform both ambient noise and earthquake Rayleigh wave tomography across South China. Combining Rayleigh wave phase velocity between 6and 40s periods from ambient noise tomography and Rayleigh wave phase velocity between 20and 140s from teleseismic two-plane-wave tomography, we obtain phase velocity maps between 6 and140 s periods. We then invert Rayleigh wave phase velocity to construct a 3-D shear wave velocity structure of South China by Markov Chain Monte Carlo method. Similar to other inversion results, our results correspond topography well. Moreover, our results also reveal that velocity structure of the eastern South China in mantle depth is similar to eastern North China, the core of the western South China, Sichuan Block (SB),still exists thick lithosphere. However, owing to much more data employed and some data quality control techniques in this research, our results reveal more detailed structures. Along Qinling-Dabie Orogenic Belt (QDOB), North-South Gravity Lineament (NSGL) and the Sichuan-Yunnan Rhombic Block (SYRB), there are obvious high speed anomalies in depths of 10-20 km, which possibly imply ancient intrusions. Moreover, it seems that Tancheng-Lujiang Fault Zone (TLFZ) has already cut through QDOB, forming a deep fracture cutting through the crust of the whole China continent. Although SB still exists thick lithosphere, there are indications for thermal erosion. At the same time, the lithosphere of the central SYRB seems to be experiencing delamination process, obviously forming a barrier to prevent the hot Tibetan Plateau (TP) mantle material from flowing further southeast. Upwelling hot mantle material possibly triggered by this delamination process might be the cause of the Emeishan Large Igneous Province. There exists an intercontinental low velocity layer in the crust of the TP

  4. High resolution in-vivo imaging of skin with full field optical coherence tomography

    Science.gov (United States)

    Dalimier, E.; Bruhat, Alexis; Grieve, K.; Harms, F.; Martins, F.; Boccara, C.

    2014-03-01

    Full-field OCT (FFOCT) has the ability to provide en-face images with a very good axial sectioning as well as a very high transverse resolution (about 1 microns in all directions). Therefore it offers the possibility to visualize biological tissues with very high resolution both on the axial native view, and on vertical reconstructed sections. Here we investigated the potential dermatological applications of in-vivo skin imaging with FFOCT. A commercial FFOCT device was adapted for the in-vivo acquisition of stacks of images on the arm, hand and finger. Several subjects of different benign and pathological skin conditions were tested. The images allowed measurement of the stratum corneum and epidermis thicknesses, measurement of the stratum corneum refractive index, size measurement and count of the keratinocytes, visualization of the dermal-epidermal junction, and visualization of the melanin granules and of the melanocytes. Skins with different pigmentations could be discriminated and skin pathologies such as eczema could be identified. The very high resolution offered by FFOCT both on axial native images and vertical reconstructed sections allows for the visualization and measurement of a set of parameters useful for cosmetology and dermatology. In particular, FFOCT is a potential tool for the understanding and monitoring of skin hydration and pigmentation, as well as skin inflammation.

  5. A new iterative reconstruction technique for attenuation correction in high-resolution positron emission tomography

    International Nuclear Information System (INIS)

    Knesaurek, K.; Machac, J.; Vallabhajosula, S.; Buchsbaum, M.S.

    1996-01-01

    A new interative reconstruction technique (NIRT) for positron emission computed tomography (PET), which uses transmission data for nonuniform attenuation correction, is described. Utilizing the general inverse problem theory, a cost functional which includes a noise term was derived. The cost functional was minimized using a weighted-least-square maximum a posteriori conjugate gradient (CG) method. The procedure involves a change in the Hessian of the cost function by adding an additional term. Two phantoms were used in a real data acquisition. The first was a cylinder phantom filled with uniformly distributed activity of 74 MBq of fluorine-18. Two different inserts were placed in the phantom. The second was a Hoffman brain phantom filled with uniformly distributed activity of 7.4 MBq of 18 F. Resulting reconstructed images were used to test and compare a new interative reconstruction technique with a standard filtered backprojection (FBP) method. The results confirmed that NIRT, based on the conjugate gradient method, converges rapidly and provides good reconstructed images. In comaprison with standard results obtained by the FBP method, the images reconstructed by NIRT showed better noise properties. The noise was measured as rms% noise and was less, by a factor of 1.75, in images reconstructed by NIRT than in the same images reconstructed by FBP. The distance between the Hoffman brain slice created from the MRI image was 0.526, while the same distance for the Hoffman brain slice reconstructed by NIRT was 0.328. The NIRT method suppressed the propagation of the noise without visible loss of resolution in the reconstructed PET images. (orig.)

  6. Transverse axial plane anatomy of the temporal bone employing high spatial resolution computed tomography

    International Nuclear Information System (INIS)

    Russell, E.J.; Koslow, M.; Lasjaunias, P.; Bergeron, R.T.; Chase, N.

    1982-01-01

    Anatomical relationships of temporal bone structures are demonstrated by thin section edge detection computed tomography. Many otic structures are best appreciated in axial view, but reorientation to anatomy as seen in this plane is needed for optimal diagnosis. A level by level review of key structure is presented toward this end. The limitations and advantages of computed tomography are discussed. (orig.)

  7. Three-dimensional reconstruction and modeling of middle ear biomechanics by high-resolution computed tomography and finite element analysis.

    Science.gov (United States)

    Lee, Chia-Fone; Chen, Peir-Rong; Lee, Wen-Jeng; Chen, Jyh-Horng; Liu, Tien-Chen

    2006-05-01

    To present a systematic and practical approach that uses high-resolution computed tomography to derive models of the middle ear for finite element analysis. This prospective study included 31 subjects with normal hearing and no previous otologic disorders. Temporal bone images obtained from 15 right ears and 16 left ears were used for evaluation and reconstruction. High-resolution computed tomography of temporal bone was performed using simultaneous acquisition of 16 sections with a collimated slice thickness of 0.625 mm. All images were transferred to an Amira visualization system for three-dimensional reconstruction. The created three-dimensional model was translated into two commercial modeling packages, Patran and ANSYS, for finite element analysis. The characteristic dimensions of the model were measured and compared with previously published histologic section data. This result confirms that the geometric model created by the proposed method is accurate except that the tympanic membrane is thicker than when measured by the histologic section method. No obvious difference in the geometrical dimension between right and left ossicles was found (P > .05). The three-dimensional model created by finite element method and predicted umbo and stapes displacements are close to the bounds of the experimental curves of Nishihara's, Huber's, Gan's, and Sun's data across the frequency range of 100 to 8000 Hz. The model includes a description of the geometry of the middle ear components and dynamic equations of vibration. The proposed method is quick, practical, low-cost, and, most importantly, noninvasive as compared with histologic section methods.

  8. Reversible bronchial dilatation in children: comparison of serial high-resolution computer tomography scans of the lungs

    Energy Technology Data Exchange (ETDEWEB)

    Gaillard, E.A. E-mail: erol.gaillard@lwh-tr.nwest.nhs.uk; Carty, H.; Heaf, D.; Smyth, R.L

    2003-09-01

    Introduction: bronchiectasis is generally considered irreversible in the adult population, largely based on studies employing bronchography in cases with a significant clinical history. It is assumed, that the same is true for children. Few studies have examined the natural history of bronchiectasis in children and diagnostic criteria on high-resolution computer tomography of the lungs are derived from studies on adults. Frequently, bronchiectasis is reported in children in cases where localised bronchial dilatation is present, incorrectly labelling these children with an irreversible life-long condition. Objective: to evaluate changes in appearance of bronchial dilatation, unrelated to cystic fibrosis in children, as assessed by sequential high-resolution computer tomography (HRCT) of the lungs. Methods: the scans of 22 children with a radiological diagnosis of bronchiectasis, seen at Alder Hey Children's Hospital between 1994 and 2000, who had at least two CT scans of the lungs were reviewed by a single radiologist, who was blinded to the original report. Results: following a median scan interval of 21 months (range 2-43), bronchial dilatation resolved completely in six children and there was improvement in appearances in a further eight, with medical treatment alone. Discussion: a radiological diagnosis of bronchiectasis should be considered with caution in children as diagnostic criteria derived from studies in adults have not been validated in children and the condition is generally considered irreversible.

  9. High-resolution optical coherence tomography, autofluorescence, and infrared reflectance imaging in Sjögren reticular dystrophy.

    Science.gov (United States)

    Schauwvlieghe, Pieter-Paul; Torre, Kara Della; Coppieters, Frauke; Van Hoey, Anneleen; De Baere, Elfride; De Zaeytijd, Julie; Leroy, Bart P; Brodie, Scott E

    2013-01-01

    To describe the phenotype of three cases of Sjögren reticular dystrophy in detail, including high-resolution optical coherence tomography, autofluorescence imaging, and near-infrared reflectance imaging. Two unrelated teenagers were independently referred for ophthalmologic evaluation. Both underwent a full ophthalmologic workup, including electrophysiologic and extensive imaging with spectral-domain optical coherence tomography, autofluorescence imaging, and near-infrared reflectance imaging. In addition, mutation screening of ABCA4, PRPH2, and the mitochondrial tRNA gene was performed in Patient 1. Subsequently, the teenage sister of Patient 2 was examined. Strikingly similar phenotypes were present in these three patients. Fundoscopy showed bilateral foveal pigment alterations, and a lobular network of deep retinal, pigmented deposits throughout the posterior pole, tapering toward the midperiphery, with relative sparing of the immediate perifoveal macula and peripapillary area. This network is mildly to moderately hyperautofluorescent on autofluorescence and bright on near-infrared reflectance imaging. Optical coherence tomography showed abnormalities of the retinal pigment epithelium-Bruch membrane complex, photoreceptor outer segments, and photoreceptor inner/outer segment interface. The results of retinal function test were entirely normal. No molecular cause was detected in Patient 1. Imaging suggested that the lobular network of deep retinal deposits in Sjögren reticular dystrophy is the result of accumulation of both pigment and lipofuscin between photoreceptors and retinal pigment epithelium, as well as within the retinal pigment epithelium.

  10. High resolution aquifer characterization using crosshole GPR full-waveform tomography

    Science.gov (United States)

    Gueting, N.; Vienken, T.; Klotzsche, A.; Van Der Kruk, J.; Vanderborght, J.; Caers, J.; Vereecken, H.; Englert, A.

    2016-12-01

    Limited knowledge about the spatial distribution of aquifer properties typically constrains our ability to predict subsurface flow and transport. Here, we investigate the value of using high resolution full-waveform inversion of cross-borehole ground penetrating radar (GPR) data for aquifer characterization. By stitching together GPR tomograms from multiple adjacent crosshole planes, we are able to image, with a decimeter scale resolution, the dielectric permittivity and electrical conductivity of an alluvial aquifer along cross-sections of 50 m length and 10 m depth. A logistic regression model is employed to predict the spatial distribution of lithological facies on the basis of the GPR results. Vertical profiles of porosity and hydraulic conductivity from direct-push, flowmeter and grain size data suggest that the GPR predicted facies classification is meaningful with regard to porosity and hydraulic conductivity, even though the distributions of individual facies show some overlap and the absolute hydraulic conductivities from the different methods (direct-push, flowmeter, grain size) differ up to approximately one order of magnitude. Comparison of the GPR predicted facies architecture with tracer test data suggests that the plume splitting observed in a tracer experiment was caused by a hydraulically low-conductive sand layer with a thickness of only a few decimeters. Because this sand layer is identified by GPR full-waveform inversion but not by conventional GPR ray-based inversion we conclude that the improvement in spatial resolution due to full-waveform inversion is crucial to detect small-scale aquifer structures that are highly relevant for solute transport.

  11. Effects of polytetrafluoroethylene treatment and compression on gas diffusion layer microstructure using high-resolution X-ray computed tomography

    Science.gov (United States)

    Khajeh-Hosseini-Dalasm, Navvab; Sasabe, Takashi; Tokumasu, Takashi; Pasaogullari, Ugur

    2014-11-01

    The microstructure of a TGP-H-120 Toray paper gas diffusion layer (GDL) was investigated using high resolution X-ray computed tomography (CT) technique, with a resolution of 1.8 μm and a field of view (FOV) of ∼1.8 × 1.8 mm. The images obtained from the tomography scans were further post processed, and image thresholding and binarization methodologies are presented. The validity of Otsu's thresholding method was examined. Detailed information on bulk porosity and porosity distribution of the GDL at various Polytetrafluoroethylene (PTFE) treatments and uniform/non-uniform compression pressures was provided. A sample holder was designed to investigate the effects of non-uniform compression pressure, which enabled regulating compression pressure between 0, and 3 MPa at a gas channel/current collector rib configuration. The results show the heterogeneous and anisotropic microstructure of the GDL, non-uniform distribution of PTFE, and significant microstructural change under uniform/non-uniform compression. These findings provide useful inputs for numerical models to include the effects of microstructural changes in the study of transport phenomena within the GDL and to increase the accuracy and predictability of cell performance.

  12. A comparative study of noise in supercontinuum light sources for ultra-high resolution optical coherence tomography

    DEFF Research Database (Denmark)

    Maria J., Sanjuan-Ferrer,; Bravo Gonzalo, Ivan; Bondu, Magalie

    2017-01-01

    Supercontinuum (SC) light is a well-established technology, which finds applications in several domains ranging from chemistry to material science and imaging systems [1-2]. More specifically, its ultra-wide optical bandwidth and high average power make it an ideal tool for Optical Coherence...... Tomography (OCT). Over the last 5 years, numerous examples have demonstrated its high potential [3-4] in this context. However, SC light sources present pulse-to-pulse intensity variation that can limit the performance of any OCT system [5] by degrading their signal to noise ratio (SNR). To this goal, we...... have studied and compared the noise of several SC light sources and evaluated how their noise properties affect the performance of Ultra-High Resolution OCT (UHR-OCT) at 1300 nm. We have measured several SC light sources with different parameters (pulse length, energy, seed repetition rate, etc.). We...

  13. High resolution Rayleigh wave group velocity tomography in North-China from ambient seismic noise

    International Nuclear Information System (INIS)

    Fang Lihua; Wu Jianping; Ding Zhifeng; Panza, G.F.

    2009-03-01

    This study presents the results of the Rayleigh wave group velocity tomography in North-China performed using ambient seismic noise observed at 190 broadband and 10 very broadband stations of the North-China Seismic Array. All available vertical component time-series for the 14 months span between January, 2007 and February, 2008 are cross-correlated to obtain empirical Rayleigh wave Green functions that are subsequently processed, with the multiple filter method, to isolate the group velocity dispersion curves of the fundamental mode of Rayleigh wave. Tomographic maps, with a grid spacing of 0.25 deg. x 0.25 deg., are computed at the periods of 4.5s, 12s, 20s, 28s. The maps at short periods reveal an evident lateral heterogeneity in the crust of North-China, quite well in agreement with known geological and tectonic features. The North China Basin is imaged as a broad low velocity area, while the Taihangshan and Yanshan uplifts and Ordos block are imaged as high velocity zones, and the Quaternary intermountain basins show up as small low-velocity anomalies. The group velocity contours at 4.5s, 12s and 20s are consistent with the Bouguer gravity anomalies measured in the area of the Taihangshan fault, that cuts through the lower crust at least. Most of the historical strong earthquakes (M≥6.0) are located where the tomographic maps show zones with moderate velocity gradient. (author)

  14. High-resolution Electrical Resistivity Tomography monitoring of a tracer test in a confined aquifer

    Science.gov (United States)

    Wilkinson, P. B.; Meldrum, P. I.; Kuras, O.; Chambers, J. E.; Holyoake, S. J.; Ogilvy, R. D.

    2010-04-01

    A permanent geoelectrical subsurface imaging system has been installed at a contaminated land site to monitor changes in groundwater quality after the completion of a remediation programme. Since the resistivities of earth materials are sensitive to the presence of contaminants and their break-down products, 4-dimensional resistivity imaging can act as a surrogate monitoring technology for tracking and visualising changes in contaminant concentrations at much higher spatial and temporal resolution than manual intrusive investigations. The test site, a municipal car park built on a former gasworks, had been polluted by a range of polycyclic aromatic hydrocarbons and dissolved phase contaminants. It was designated statutory contaminated land under Part IIA of the UK Environmental Protection Act due to the risk of polluting an underlying minor aquifer. Resistivity monitoring zones were established on the boundaries of the site by installing vertical electrode arrays in purpose-drilled boreholes. After a year of monitoring data had been collected, a tracer test was performed to investigate groundwater flow velocity and to demonstrate rapid volumetric monitoring of natural attenuation processes. A saline tracer was injected into the confined aquifer, and its motion and evolution were visualised directly in high-resolution tomographic images in near real-time. Breakthrough curves were calculated from independent resistivity measurements, and the estimated seepage velocities from the monitoring images and the breakthrough curves were found to be in good agreement with each other and with estimates based on the piezometric gradient and assumed material parameters.

  15. Pollen structure visualization using high-resolution laboratory-based hard X-ray tomography.

    Science.gov (United States)

    Li, Qiong; Gluch, Jürgen; Krüger, Peter; Gall, Martin; Neinhuis, Christoph; Zschech, Ehrenfried

    2016-10-14

    A laboratory-based X-ray microscope is used to investigate the 3D structure of unstained whole pollen grains. For the first time, high-resolution laboratory-based hard X-ray microscopy is applied to study pollen grains. Based on the efficient acquisition of statistically relevant information-rich images using Zernike phase contrast, both surface- and internal structures of pine pollen - including exine, intine and cellular structures - are clearly visualized. The specific volumes of these structures are calculated from the tomographic data. The systematic three-dimensional study of pollen grains provides morphological and structural information about taxonomic characters that are essential in palynology. Such studies have a direct impact on disciplines such as forestry, agriculture, horticulture, plant breeding and biodiversity. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. High-resolution computed tomography of the toothed jaw compared with histologic microsections

    International Nuclear Information System (INIS)

    Klein, H.M.; Fuhrmann, R.; Diedrich, P.; Guenther, R.W.

    1993-01-01

    Human bone segments of the toothed jaw were scanned using high-resolution CT with axial and coronal contiguous 1 and 2 mm slices. The bone segments were sliced analogous to the performed CT image positions. Contact films and micro-sections were made from the cuttings. Length and width of the teeth, the thickness of the alveolar bone and the distance between bone and dental surface were measured. Comparison of the CT measurements with contact films and histological specimen yielded best results for axial slices with 1 mm slice thickness (mean error 0.3-0.5 mm). Coronary oriented slices showed an error of 0.3-1.6 mm. 3D-reformatting can improve spatial orientation for axially produced image series. For CT imaging of the toothed jaw concerning the dento-alveolar structures, contiguous axial scanning with 1 mm slice thickness appears to be the concept of choice. (orig.) [de

  17. Automated high resolution full-field spatial coherence tomography for quantitative phase imaging of human red blood cells

    Science.gov (United States)

    Singla, Neeru; Dubey, Kavita; Srivastava, Vishal; Ahmad, Azeem; Mehta, D. S.

    2018-02-01

    We developed an automated high-resolution full-field spatial coherence tomography (FF-SCT) microscope for quantitative phase imaging that is based on the spatial, rather than the temporal, coherence gating. The Red and Green color laser light was used for finding the quantitative phase images of unstained human red blood cells (RBCs). This study uses morphological parameters of unstained RBCs phase images to distinguish between normal and infected cells. We recorded the single interferogram by a FF-SCT microscope for red and green color wavelength and average the two phase images to further reduced the noise artifacts. In order to characterize anemia infected from normal cells different morphological features were extracted and these features were used to train machine learning ensemble model to classify RBCs with high accuracy.

  18. Anterior Chamber Angle Measurements Using Schwalbe's Line with High Resolution Fourier-Domain Optical Coherence Tomography

    Science.gov (United States)

    Qin, Bing; Francis, Brian A.; Li, Yan; Tang, Maolong; Zhang, Xinbo; Jiang, Chunhui; Cleary, Catherine; Huang, David

    2012-01-01

    Purpose To use Fourier-domain optical coherence tomography (OCT) to measure the angle opening distance at Schwalbe's line (AOD-SL) and determine its value in anterior chamber angle assessment. Methods Horizontal scans of the nasal and temporal anterior chamber angles in glaucoma subjects were performed by 830 nm wavelength Fourier-domain OCT. Images were graded by two ophthalmologists who assessed the visibility of Schwalbe’s line (SL), anterior limbus (AL), scleral spur (SS), and angle recess (AR). AOD-SL was measured with computer calipers. SL was manually identified by the termination of the corneal endothelium. Gonioscopy was used to classify anterior chamber angles according to a modified Shaffer system. Spearman's rho analysis was performed to assess correlation between AOD-SL and modified Shaffer grade. A cut-off value of AOD-SL for diagnosing occludable angles (modified Shaffer grade ≤1) was determined by receiver operating characteristic (ROC) analyses. Results Thirty-five glaucoma subjects (65 eyes) were enrolled. SL, AL, AR, and SS were visible by OCT in 97.7%, 99.2%, 87.3%, and 80.8% of eyes, respectively. Nasal and temporal AOD-SLs were 322.6 ± 200.2 µm and 341.4 ± 197.4 µm, respectively. Correlation coefficients between AOD-SL and modified Shaffer grade were 0.80 (nasal) and 0.81 (temporal). The diagnostic cut-off value of AOD-SL for occludable angles was 290 µm. The areas under the ROC curve, sensitivity, specificity values were 0.90, 0.80, 0.87 (nasal) and 0.90, 0.85, 0.77 (temporal). Conclusions The measurement of AOD-SL by Fourier-domain OCT is highly correlated with gonioscopy and may be a useful noncontact method of assessing angle closure risk. PMID:22827999

  19. Breaking the Crowther limit: Combining depth-sectioning and tilt tomography for high-resolution, wide-field 3D reconstructions

    International Nuclear Information System (INIS)

    Hovden, Robert; Ercius, Peter; Jiang, Yi; Wang, Deli; Yu, Yingchao; Abruña, Héctor D.; Elser, Veit; Muller, David A.

    2014-01-01

    To date, high-resolution ( 6 nm) to appear blurred or missing. Here we demonstrate a three-dimensional imaging method that overcomes both these limits by combining through-focal depth sectioning and traditional tilt-series tomography to reconstruct extended objects, with high-resolution, in all three dimensions. The large convergence angle in aberration corrected instruments now becomes a benefit and not a hindrance to higher quality reconstructions. A through-focal reconstruction over a 390 nm 3D carbon support containing over 100 dealloyed and nanoporous PtCu catalyst particles revealed with sub-nanometer detail the extensive and connected interior pore structure that is created by the dealloying instability. - Highlights: • Develop tomography technique for high-resolution and large field of view. • We combine depth sectioning with traditional tilt tomography. • Through-focal tomography reduces tilts and improves resolution. • Through-focal tomography overcomes the fundamental Crowther limit. • Aberration-corrected becomes a benefit and not a hindrance for tomography

  20. High resolution feature extraction from optical coherence tomography acquired internal fingerprint

    CSIR Research Space (South Africa)

    Khutlang, Rethabile

    2016-05-01

    Full Text Available coherence tomography (OCT) can be used to scan the internal skin features, up to the depth of the papillary layer. OCT is contactless and scans in three dimensions. The papillary contour represents an internal fingerprint, which does not suffer external skin...

  1. Using high resolution X-ray computed tomography to create an image based model of a lymph node.

    Science.gov (United States)

    Cooper, L J; Zeller-Plumhoff, B; Clough, G F; Ganapathisubramani, B; Roose, T

    2018-07-14

    Lymph nodes are an important part of the immune system. They filter the lymphatic fluid as it is transported from the tissues before being returned to the blood stream. The fluid flow through the nodes influences the behaviour of the immune cells that gather within the nodes and the structure of the node itself. Measuring the fluid flow in lymph nodes experimentally is challenging due to their small size and fragility. In this paper, we present high resolution X-ray computed tomography images of a murine lymph node. The impact of the resulting visualized structures on fluid transport are investigated using an image based model. The high contrast between different structures within the lymph node provided by phase contrast X-ray computed tomography reconstruction results in images that, when related to the permeability of the lymph node tissue, suggest an increased fluid velocity through the interstitial channels in the lymph node tissue. Fluid taking a direct path from the afferent to the efferent lymphatic vessel, through the centre of the node, moved faster than the fluid that flowed around the periphery of the lymph node. This is a possible mechanism for particles being moved into the cortex. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Examination of the fine interstitial changes of pneumoconiosis with high resolution computed tomography (HR-CT)

    International Nuclear Information System (INIS)

    Kido, Masamitsu; Miyazaki, Nobuyoshi; Harada, Susumu; Nakata, Hajime

    1986-01-01

    High resolution CT was performed in 14 patients with fine interstitial changes of pneumoconiosis and Review image was evaluated for the diagnostic accuracy as compared with conventional chest roentgenogram. Of the 14 Patients in the study, 7 were divided category 1 by the ILO U/C classification, 4 were category 2, 3 were category 3. Studies of lung function showed obstructive ventilatory disturbance characterized by moderate reduction in FEV 1.0% (58.6 ± 16.5 %) and V25/H (0.34 ± 0.24 l/sec/m). HR-CT defined more sensitive in the presence of fine lung nodules than conventional X-p, and showed high contrast interfaces provided by the aerated lung. HR-CT was also of value in detecting bulla, bleb, peripleural changes and hilar lymphadenopathy. Radiologic-pathologic correlation was examined on tne specimens of transbronchial lung biopsy in 4 patients, and revealed the diagnostic usefullness of HR-CT. (author)

  3. Quantitative assessment of liquid Ga penetration into an aluminium alloy by high-resolution X-ray tomography

    International Nuclear Information System (INIS)

    Ohgaki, T.; Toda, H.; Sinclair, I.; Buffiere, J.-Y.; Ludwig, W.; Kobayashi, T.; Niinomi, M.; Akahori, T.

    2005-01-01

    We have evaluated the liquid Ga penetration into an aluminium alloy by high-resolution X-ray tomography. The 3D visualization of a crack together with its surrounding grain structure was performed with the help of the Ga penetration technique. It is found that the advance directions of the crack-tip were strongly influenced by the grain microstructure and the branching of the crack is affected by grain distribution. In this study, the liquid Ga not only acts as a contrast agent for grain boundaries, but also expands the volume of the Al alloy due to Ga diffusion and associated processes. The 3D strain between the grains has been determined by microstructural gauging technique, which uses micropores as marker points. The 3D expansion of the sample volume, the volume reduction of micropores and the brittle fracture were evidently observed

  4. Comparison of high-resolution computed tomography findings between Pseudomonas aeruginosa pneumonia and Cytomegalovirus pneumonia

    International Nuclear Information System (INIS)

    Omeri, Ahmad Khalid; Okada, Fumito; Takata, Shoko; Ono, Asami; Sato, Haruka; Mori, Hiromu; Nakayama, Tomoko; Ando, Yumiko; Hiramatsu, Kazufumi

    2014-01-01

    To compare pulmonary high-resolution CT (HRCT) findings in patients with Pseudomonas aeruginosa pneumonia to HRCT findings in patients with Cytomegalovirus (CMV) pneumonia. We studied 124 patients (77 men, 47 women; age range, 20-89 years; mean age, 65.4 years) with P. aeruginosa pneumonia and 44 patients (22 men, 22 women; age range, 36-86 years; mean age, 63.2 years) with CMV pneumonia. CT findings of consolidation (p < 0.005), bronchial wall thickening (p < 0.001), cavity (p < 0.05), and pleural effusion (p < 0.001) were significantly more frequent in patients with P. aeruginosa pneumonia than in those with CMV pneumonia. Centrilobular nodules, a crazy-paving appearance, and nodules were significantly more frequent in patients with CMV pneumonia than in those with P. aeruginosa pneumonia (all p < 0.001). Pulmonary HRCT findings, such as bronchial wall thickening, crazy-paving appearance, and nodules may be useful in distinguishing between P. aeruginosa pneumonia and CMV pneumonia. (orig.)

  5. Comparison of high-resolution computed tomography findings between Pseudomonas aeruginosa pneumonia and Cytomegalovirus pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Omeri, Ahmad Khalid; Okada, Fumito; Takata, Shoko; Ono, Asami; Sato, Haruka; Mori, Hiromu [Oita University Faculty of Medicine, Department of Radiology, Yufu, Oita (Japan); Nakayama, Tomoko [Oita Red Cross Hospital, Department of Radiology, Oita (Japan); Ando, Yumiko [Oita Nishibeppu National Hospital, Department of Radiology, Oita (Japan); Hiramatsu, Kazufumi [Oita University Hospital, Hospital Infection Control Center, Oita (Japan)

    2014-12-15

    To compare pulmonary high-resolution CT (HRCT) findings in patients with Pseudomonas aeruginosa pneumonia to HRCT findings in patients with Cytomegalovirus (CMV) pneumonia. We studied 124 patients (77 men, 47 women; age range, 20-89 years; mean age, 65.4 years) with P. aeruginosa pneumonia and 44 patients (22 men, 22 women; age range, 36-86 years; mean age, 63.2 years) with CMV pneumonia. CT findings of consolidation (p < 0.005), bronchial wall thickening (p < 0.001), cavity (p < 0.05), and pleural effusion (p < 0.001) were significantly more frequent in patients with P. aeruginosa pneumonia than in those with CMV pneumonia. Centrilobular nodules, a crazy-paving appearance, and nodules were significantly more frequent in patients with CMV pneumonia than in those with P. aeruginosa pneumonia (all p < 0.001). Pulmonary HRCT findings, such as bronchial wall thickening, crazy-paving appearance, and nodules may be useful in distinguishing between P. aeruginosa pneumonia and CMV pneumonia. (orig.)

  6. Cost-Effective and High-Resolution Subsurface Characterization Using Hydraulic Tomography

    Science.gov (United States)

    2017-08-28

    of this project is to provide the Department of Defense (DoD) and its remediation contractors with the Hydraulic Tomography ( HT ) technology for...objective of this project is to provide the DoD and its remediation contractors with the HT technology for delineating the spatial distribution of the...SPONSOR/MONITOR’S REPORT NUMBER(S) ER-201212 The overall objective of this project is to provide the DoD and its remediation contractors with the

  7. Simultaneous Confocal Scanning Laser Ophthalmoscopy Combined with High-Resolution Spectral-Domain Optical Coherence Tomography: A Review

    Directory of Open Access Journals (Sweden)

    Verônica Castro Lima

    2011-01-01

    Full Text Available We aimed to evaluate technical aspects and the clinical relevance of a simultaneous confocal scanning laser ophthalmoscope and a high-speed, high-resolution, spectral-domain optical coherence tomography (SDOCT device for retinal imaging. The principle of confocal scanning laser imaging provides a high resolution of retinal and choroidal vasculature with low light exposure. Enhanced contrast, details, and image sharpness are generated using confocality. The real-time SDOCT provides a new level of accuracy for assessment of the angiographic and morphological correlation. The combined system allows for simultaneous recordings of topographic and tomographic images with accurate correlation between them. Also it can provide simultaneous multimodal imaging of retinal pathologies, such as fluorescein and indocyanine green angiographies, infrared and blue reflectance (red-free images, fundus autofluorescence images, and OCT scans (Spectralis HRA + OCT; Heidelberg Engineering, Heidelberg, Germany. The combination of various macular diagnostic tools can lead to a better understanding and improved knowledge of macular diseases.

  8. Potentials of high resolution magnetic resonance imaging versus computed tomography for preoperative local staging of colon cancer

    International Nuclear Information System (INIS)

    Rollven, Erik; Blomqvist, Lennart; Holm, Torbjorn; Glimelius, Bengt; Loerinc, Esther

    2013-01-01

    Background: Preoperative identification of locally advanced colon cancer is of importance in order to properly plan treatment. Purpose: To study high resolution T2-weighted magnetic resonance imaging (MRI) versus computed tomography (CT) for preoperative staging of colon cancer with surgery and histopathology as reference standard. Material and Methods: Twenty-eight patients with a total of 29 tumors were included. Patients were examined on a 1.5 T MR unit using a phased array body coil. T2 turbo spin-echo high resolution sequences were obtained in a coronal, transverse, and perpendicular plane to the long axis of the colon at the site of the tumor. Contrast-enhanced CT was performed using a protocol for metastasis staging. The examinations were independently evaluated by two gastrointestinal radiologists using criteria adapted to imaging for prediction of T-stage, N-stage, and extramural venous invasion. Based on the T-stage, tumors were divided in to locally advanced (T3cd-T4) and not locally advanced (T1-T3ab). Surgical and histopathological findings served as reference standard. Results: Using MRI, T-stage, N-stage, and extramural venous invasion were correctly predicted for each observer in 90% and 93%, 72% and 69%, and 82% and 78% of cases, respectively. With CT the corresponding results were 79% and 76%, 72% and 72%, 78% and 67%. For MRI inter-observer agreements (Kappa statistics) were 0.79, 0.10, and 0.76. For CT the corresponding results were 0.64, 0.66, and 0.22. Conclusion: Patients with locally advanced colon cancer, defined as tumor stage T3cd-T4, can be identified by both high resolution MRI and CT, even when CT is performed with a metastasis staging protocol. MRI may have an advantage, due to its high soft tissue discrimination, to identify certain prognostic factors such as T-stage and extramural venous invasion

  9. Potentials of high resolution magnetic resonance imaging versus computed tomography for preoperative local staging of colon cancer

    Energy Technology Data Exchange (ETDEWEB)

    Rollven, Erik; Blomqvist, Lennart [Dept. of Diagnostic Radiology, Karolinska Univ. Hospital Solna, Stockholm (Sweden); Dept. of Molecular Medicine and Surgery, Karolinska Inst., Stockholm (Sweden)], e-mail: erik.rollven@ki.se; Holm, Torbjorn [Dept. of Molecular Medicine and Surgery, Karolinska Inst., Stockholm (Sweden); Dept. of Surgery, Karolinska Univ. Hospital Solna, Stockholm (Sweden); Glimelius, Bengt [Dept. of Radiology, Oncology and Radiation Science, Uppsala Univ., Uppsala (Sweden); Dept. of Oncology and Pathology, Karolinska Inst., Stockholm (Sweden); Loerinc, Esther [Dept. of Oncology and Pathology, Karolinska Inst., Stockholm (Sweden); Dept. of Pathology, Karolinska Univ. Hospital, Solna, Sweden (Sweden)

    2013-09-15

    Background: Preoperative identification of locally advanced colon cancer is of importance in order to properly plan treatment. Purpose: To study high resolution T2-weighted magnetic resonance imaging (MRI) versus computed tomography (CT) for preoperative staging of colon cancer with surgery and histopathology as reference standard. Material and Methods: Twenty-eight patients with a total of 29 tumors were included. Patients were examined on a 1.5 T MR unit using a phased array body coil. T2 turbo spin-echo high resolution sequences were obtained in a coronal, transverse, and perpendicular plane to the long axis of the colon at the site of the tumor. Contrast-enhanced CT was performed using a protocol for metastasis staging. The examinations were independently evaluated by two gastrointestinal radiologists using criteria adapted to imaging for prediction of T-stage, N-stage, and extramural venous invasion. Based on the T-stage, tumors were divided in to locally advanced (T3cd-T4) and not locally advanced (T1-T3ab). Surgical and histopathological findings served as reference standard. Results: Using MRI, T-stage, N-stage, and extramural venous invasion were correctly predicted for each observer in 90% and 93%, 72% and 69%, and 82% and 78% of cases, respectively. With CT the corresponding results were 79% and 76%, 72% and 72%, 78% and 67%. For MRI inter-observer agreements (Kappa statistics) were 0.79, 0.10, and 0.76. For CT the corresponding results were 0.64, 0.66, and 0.22. Conclusion: Patients with locally advanced colon cancer, defined as tumor stage T3cd-T4, can be identified by both high resolution MRI and CT, even when CT is performed with a metastasis staging protocol. MRI may have an advantage, due to its high soft tissue discrimination, to identify certain prognostic factors such as T-stage and extramural venous invasion.

  10. Changes in bone macro- and microstructure in diabetic obese mice revealed by high resolution microfocus X-ray computed tomography

    Science.gov (United States)

    Kerckhofs, G.; Durand, M.; Vangoitsenhoven, R.; Marin, C.; van der Schueren, B.; Carmeliet, G.; Luyten, F. P.; Geris, L.; Vandamme, K.

    2016-10-01

    High resolution microfocus X-ray computed tomography (HR-microCT) was employed to characterize the structural alterations of the cortical and trabecular bone in a mouse model of obesity-driven type 2 diabetes (T2DM). C57Bl/6J mice were randomly assigned for 14 weeks to either a control diet-fed (CTRL) or a high fat diet (HFD)-fed group developing obesity, hyperglycaemia and insulin resistance. The HFD group showed an increased trabecular thickness and a decreased trabecular number compared to CTRL animals. Midshaft tibia intracortical porosity was assessed at two spatial image resolutions. At 2 μm scale, no change was observed in the intracortical structure. At 1 μm scale, a decrease in the cortical vascular porosity of the HFD bone was evidenced. The study of a group of 8 week old animals corresponding to animals at the start of the diet challenge revealed that the decreased vascular porosity was T2DM-dependant and not related to the ageing process. Our results offer an unprecedented ultra-characterization of the T2DM compromised skeletal micro-architecture and highlight an unrevealed T2DM-related decrease in the cortical vascular porosity, potentially affecting the bone health and fragility. Additionally, it provides some insights into the technical challenge facing the assessment of the rodent bone structure using HR-microCT imaging.

  11. Pulmonary leukemic involvement: high-resolution computed tomography evaluation; Comprometimento pulmonar nas leucemias: avaliacao por tomografia computadorizada de alta resolucao

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Ana Paola de [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Programa de Pos-graduacao em Radiologia; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Souza, Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Dept. de Radiologia

    2004-12-01

    Objective: To evaluate the role of high-resolution computed tomography (HRCT) in patients with leukemia and pulmonary symptoms, to establish the main patterns and to correlate them with the etiology. Materials and Methods: This is a retrospective study of the HRCT of 15 patients with leukemia and pulmonary symptoms. The examinations were performed using a spatial high-resolution protocol and were analyzed by two independent radiologists. Results: The main HRCT patterns found were ground-glass opacity (n=11), consolidation (n=9), airspace nodules (n=3), septal thickening (n=3), tree-in-bud pattern (n=3), and pleural effusion (n=3). Pulmonary infection was the most common finding seen in 12 patients: bacterial pneumonia (n=6), fungal infection (n = 4), pulmonary tuberculosis (n=1) and viral infection (n=1). Leukemic pleural infiltration (n=1), lymphoma (n=1) and pulmonary hemorrhage (n=1) were detected in the other three patients. Conclusion: HRCT is an important tool that may suggest the cause of lung involvement, its extension and in some cases to guide invasive procedures in patients with leukemia. (author)

  12. Changes in bone macro- and microstructure in diabetic obese mice revealed by high resolution microfocus X-ray computed tomography

    Science.gov (United States)

    Kerckhofs, G.; Durand, M.; Vangoitsenhoven, R.; Marin, C.; Van der Schueren, B.; Carmeliet, G.; Luyten, F. P.; Geris, L.; Vandamme, K.

    2016-01-01

    High resolution microfocus X-ray computed tomography (HR-microCT) was employed to characterize the structural alterations of the cortical and trabecular bone in a mouse model of obesity-driven type 2 diabetes (T2DM). C57Bl/6J mice were randomly assigned for 14 weeks to either a control diet-fed (CTRL) or a high fat diet (HFD)-fed group developing obesity, hyperglycaemia and insulin resistance. The HFD group showed an increased trabecular thickness and a decreased trabecular number compared to CTRL animals. Midshaft tibia intracortical porosity was assessed at two spatial image resolutions. At 2 μm scale, no change was observed in the intracortical structure. At 1 μm scale, a decrease in the cortical vascular porosity of the HFD bone was evidenced. The study of a group of 8 week old animals corresponding to animals at the start of the diet challenge revealed that the decreased vascular porosity was T2DM-dependant and not related to the ageing process. Our results offer an unprecedented ultra-characterization of the T2DM compromised skeletal micro-architecture and highlight an unrevealed T2DM-related decrease in the cortical vascular porosity, potentially affecting the bone health and fragility. Additionally, it provides some insights into the technical challenge facing the assessment of the rodent bone structure using HR-microCT imaging. PMID:27759061

  13. High-resolution time-lapse tomography of rat vertebrae during compressive loading: deformation response analysis

    Czech Academy of Sciences Publication Activity Database

    Fíla, Tomáš; Kytýř, Daniel; Zlámal, Petr; Kumpová, Ivana; Doktor, Tomáš; Koudelka_ml., Petr; Jiroušek, Ondřej

    2014-01-01

    Roč. 9, May (2014), C05054 ISSN 1748-0221. [International workshop on radiation imaging detectors /15./. Paris, 23.06.2013-27.06.2013] R&D Projects: GA ČR(CZ) GAP105/10/2305; GA MŠk(CZ) LO1219 Institutional support: RVO:68378297 Keywords : image reconstruction in medical imaging * computerized tomography * computed radiography Subject RIV: JJ - Other Materials Impact factor: 1.399, year: 2014 http://iopscience.iop.org/1748-0221/9/05/C05054

  14. Resolution, sensitivity, and in vivo application of high-resolution computed tomography for titanium-coated polymethyl methacrylate (PMMA) dental implants

    NARCIS (Netherlands)

    Cuijpers, V.M.J.I.; Jaroszewicz, J.; Anil, S.; Al Farraj Aldosari, A.; Walboomers, X.F.; Jansen, J.A.

    2014-01-01

    OBJECTIVES: The aims of this study were (i) to determine the spatial resolution and sensitivity of micro- versus nano-computed tomography (CT) techniques and (ii) to validate micro- versus nano-CT in a dog dental implant model, comparative to histological analysis. MATERIAL AND METHODS: To determine

  15. Segmentation methodology for automated classification and differentiation of soft tissues in multiband images of high-resolution ultrasonic transmission tomography.

    Science.gov (United States)

    Jeong, Jeong-Won; Shin, Dae C; Do, Synho; Marmarelis, Vasilis Z

    2006-08-01

    This paper presents a novel segmentation methodology for automated classification and differentiation of soft tissues using multiband data obtained with the newly developed system of high-resolution ultrasonic transmission tomography (HUTT) for imaging biological organs. This methodology extends and combines two existing approaches: the L-level set active contour (AC) segmentation approach and the agglomerative hierarchical kappa-means approach for unsupervised clustering (UC). To prevent the trapping of the current iterative minimization AC algorithm in a local minimum, we introduce a multiresolution approach that applies the level set functions at successively increasing resolutions of the image data. The resulting AC clusters are subsequently rearranged by the UC algorithm that seeks the optimal set of clusters yielding the minimum within-cluster distances in the feature space. The presented results from Monte Carlo simulations and experimental animal-tissue data demonstrate that the proposed methodology outperforms other existing methods without depending on heuristic parameters and provides a reliable means for soft tissue differentiation in HUTT images.

  16. High resolution coherence domain depth-resolved nailfold capillaroscopy based on correlation mapping optical coherence tomography

    Science.gov (United States)

    Subhash, Hrebesh M.; O'Gorman, Sean; Neuhaus, Kai; Leahy, Martin

    2014-03-01

    In this paper we demonstrate a novel application of correlation mapping optical coherence tomography (cm-OCT) for volumetric nailfold capillaroscopy (NFC). NFC is a widely used non-invasive diagnostic method to analyze capillary morphology and microvascular abnormalities of nailfold area for a range of disease conditions. However, the conventional NFC is incapable of providing volumetric imaging, when volumetric quantitative microangiopathic parameters such as plexus morphology, capillary density, and morphologic anomalies of the end row loops most critical. cm-OCT is a recently developed well established coherence domain magnitude based angiographic modality, which takes advantage of the time-varying speckle effect, which is normally dominant in the vicinity of vascular regions compared to static tissue region. It utilizes the correlation coefficient as a direct measurement of decorrelation between two adjacent B-frames to enhance the visibility of depth-resolved microcirculation.

  17. Three dimensional characterization of laser ablation craters using high resolution X-ray computed tomography

    Science.gov (United States)

    Galmed, A. H.; du Plessis, A.; le Roux, S. G.; Hartnick, E.; Von Bergmann, H.; Maaza, M.

    2018-01-01

    Laboratory X-ray computed tomography is an emerging technology for the 3D characterization and dimensional analysis of many types of materials. In this work we demonstrate the usefulness of this characterization method for the full three dimensional analysis of laser ablation craters, in the context of a laser induced breakdown spectroscopy setup. Laser induced breakdown spectroscopy relies on laser ablation for sampling the material of interest. We demonstrate here qualitatively (in images) and quantitatively (in terms of crater cone angles, depths, diameters and volume) laser ablation crater analysis in 3D for metal (aluminum) and rock (false gold ore). We show the effect of a Gaussian beam profile on the resulting crater geometry, as well as the first visual evidence of undercutting in the rock sample, most likely due to ejection of relatively large grains. The method holds promise for optimization of laser ablation setups especially for laser induced breakdown spectroscopy.

  18. Crazy-paving sign in high-resolution computed tomography in parainfluenza virus pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Matsuno, Osamu [Department of Respiratory Disease, NHO National Osaka Minami Medical Center, Kido higashi machi 2-1, Kawachinagano City, Osaka 586-8521 (Japan)], E-mail: matsuno@ommc-hp.jp; Hayama, Yoshitomo; Honda, Hidehiro; Yamane, Hiroyuki; Yamamoto, Suguru; Ueno, Kiyonobu [Department of Respiratory Disease, NHO National Osaka Minami Medical Center, Kido higashi machi 2-1, Kawachinagano City, Osaka 586-8521 (Japan); Saeki, Yukihiko [Department of Clinical Research, NHO National Osaka Minami Medical Center, Kido higashi machi 2-1, Kawachinagano city, Osaka 586-8521 (Japan)

    2010-05-15

    The crazy-paving sign is the appearance of a smooth linear pattern superimposed on an area of ground-glass opacity on thin-section computed tomography (CT). A 69-year-old woman was admitted to our hospital for treatment of pneumonia. Thoracic CT showed a crazy-paving sign in the right lung field on admission. She received ceftriaxone and clarithromycin, and the symptoms and infiltration shadow promptly disappeared. Serologic testing revealed a greater than 4-fold increase in the IgG titer for parainfluenza virus I. To our knowledge, there is no previous report of the crazy-paving sign in associated with viral pneumonia in a non-immunocompromised host or with parainfluenza pneumonia.

  19. Ultra-low noise supercontinuum source for ultra-high resolution optical coherence tomography at 1300 nm

    Science.gov (United States)

    Gonzalo, I. B.; Maria, M.; Engelsholm, R. D.; Feuchter, T.; Leick, L.; Moselund, P. M.; Podoleanu, A.; Bang, O.

    2018-02-01

    Supercontinuum (SC) sources are of great interest for many applications due to their ultra-broad optical bandwidth, good beam quality and high power spectral density [1]. In particular, the high average power over large bandwidths makes SC light sources excellent candidates for ultra-high resolution optical coherence tomography (UHR-OCT) [2-5]. However, conventional SC sources suffer from high pulse-to-pulse intensity fluctuations as a result of the noise-sensitive nonlinear effects involved in the SC generation process [6-9]. This intensity noise from the SC source can limit the performance of OCT, resulting in a reduced signal-to-noise ratio (SNR) [10-12]. Much work has been done to reduce the noise of the SC sources for instance with fiber tapers [7,8] or increasing the repetition rate of the pump laser for averaging in the spectrometer [10,12]. An alternative approach is to use all-normal dispersion (ANDi) fibers [13,14] to generate SC light from well-known coherent nonlinear processes [15-17]. In fact, reduction of SC noise using ANDi fibers compared to anomalous dispersion SC pumped by sub-picosecond pulses has been recently demonstrated [18], but a cladding mode was used to stabilize the ANDi SC. In this work, we characterize the noise performance of a femtosecond pumped ANDi based SC and a commercial SC source in an UHR-OCT system at 1300 nm. We show that the ANDi based SC presents exceptional noise properties compared to a commercial source. An improvement of 5 dB in SNR is measured in the UHR-OCT system, and the noise behavior resembles that of a superluminiscent diode. This preliminary study is a step forward towards development of an ultra-low noise SC source at 1300 nm for ultra-high resolution OCT.

  20. Can high-resolution peripheral quantitative computed tomography imaging of subchondral and cortical bone predict condylar fracture in Thoroughbred racehorses?

    Science.gov (United States)

    Trope, G D; Ghasem-Zadeh, A; Anderson, G A; Mackie, E J; Whitton, R C

    2015-07-01

    High-resolution 3D imaging may improve the prediction and/or early identification of condylar fractures of the distal metacarpus/tarsus and reduce the frequency of breakdown injury in racehorses. To test the hypotheses that horses suffering condylar fractures have higher bone volume fraction (BV/TV) of the distal metacarpal epiphysis, greater subchondral bone thickness at the fracture site and higher second moment of inertia in the metacarpal midshaft as identified with high-resolution 3D imaging. Cross-sectional study using cadaver material. Thoroughbreds that died on racetracks were grouped as: 1) horses with third metacarpal (McIII) fractures with a condylar component (cases, n = 13); 2) horses with no limb fracture (controls, n = 8); 3) horses with fractures in other bones or suspensory apparatus disruption (other fatal injuries, n = 16). The palmar condyles of McIII and the midshaft were examined with high resolution peripheral quantitative computed tomography (HR-pQCT). Statistical analysis included logistic regression and Spearman's correlation. There were no significant differences in BV/TV of distal McIII and second moment of inertia of the midshaft between cases and controls. Epiphyseal bone BV/TV was greater in injured limbs of horses with any fatal limb injury (Groups 1 and 3 combined) compared with controls (odds ratio = 1.20, 95% confidence interval 1.01-1.42, P = 0.034). An epiphyseal BV/TV>0.742 resulted in a sensitivity of 82.8% and specificity of 62.5% in identifying horses with fatal limb injury. In horses without condylar fracture, increased subchondral bone thickness was associated with palmar osteochondral disease lesions in the adjacent condyle (rs = 0.65, Phorses at risk of any fatal breakdown injury but not metacarpal condylar fractures. Measurement of parasagittal groove subchondral bone thickness is complicated by adjacent palmar osteochondral disease lesions. Thus, high-resolution imaging of the distal metacarpus appears to have limited

  1. The Dimensions of the Orbital Cavity Based on High-Resolution Computed Tomography of Human Cadavers

    DEFF Research Database (Denmark)

    Felding, Ulrik Ascanius; Bloch, Sune Land; Buchwald, Christian von

    2016-01-01

    for surface area. To authors' knowledge, this study is the first to have measured the entire surface area of the orbital cavity.The volume and surface area of the orbital cavity were estimated in computed tomography scans of 11 human cadavers using unbiased stereological sampling techniques. The mean (± SD......) total volume and total surface area of the orbital cavities was 24.27 ± 3.88 cm and 32.47 ± 2.96 cm, respectively. There was no significant difference in volume (P = 0.315) or surface area (P = 0.566) between the 2 orbital cavities.The stereological technique proved to be a robust and unbiased method...... that may be used as a gold standard for comparison with automated computer software. Future imaging studies in blow-out fracture patients may be based on individual and relative calculation involving both herniated volume and fractured surface area in relation to the total volume and surface area...

  2. Experimental studies of the visualisation of spongious bone by high resolution computed tomography

    International Nuclear Information System (INIS)

    Henschel, M.G.; Freyschmidt, J.; Holland, B.R.

    1995-01-01

    18 native human lumbar vertebrae were placed in a water phantom and examined by HR-CT. The scans were compared with contact radiographs of correlating thin bone sections by morphologic criteria. The measured lower limit of visualisation of cancellous bone structures is celarly worse than expected from the measurements of spatial resolution with standard phantoms used for HR-CT (0.6 versus 0.4 mm). True and exact imaging of normal cancellous bone cannot be achieved even by modern HR-CT. Noise creates structures mimicking cancellous bone. (orig./MG) [de

  3. Pulmonary malaria: high-resolution computed tomography findings - a case report; Malaria pulmonar: aspectos na tomografia computadorizada de alta resolucao - relato de caso

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Rosana; Souza, Daniel Andrade Tinoco de [Universidade Federal, Rio de Janeiro, RJ (Brazil). Hospital Universitario Clementino Fraga Filho. Servico de Radiodiagnostico; Hospital Copa D' Or, Rio de Janeiro, RJ (Brazil); Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: edmarchiori@bol.com.br

    2004-04-01

    We report the case of a 38-year-old man with pulmonary malaria. High-resolution computed tomography showed thickening of the peribronchovascular interstitium and interlobular septa, areas of consolidation and ground glass attenuation and bilateral pleural effusion suggesting pulmonary edema. The patient recovered well after receiving specific treatment and was discharged after 11 days of hospitalization. (author)

  4. Diffuse lung neoplasms. Correlation between high resolution computerized tomography and anatomopathology; Neoplasias pulmonares difusas: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Irion, Klaus L. [Complexo Hospitalar Santa Casa de Porto Alegre, RS (Brazil). Servico de Radiologia do Pavilhao Pereira Filho; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto, SP (Brazil)]. E-mail: edmarchiori@zipmail.com.br

    2002-08-01

    A short comparative evaluation study between high resolution computerized tomography and anatomopathologic findings is presented. The association of these two diagnostic techniques is discussed as a factor to enhance the accuracy of diffuse lung diseases, such as carcinomatous lymphangitis, Kaposi's Sarcoma, lymphomas, hematogenic metastases, bronchiole-alveolar carcinoma and leukemia. (MAC)

  5. Imaging of cellular spread on a three-dimensional scaffold by means of a novel cell-labeling technique for high-resolution computed tomography

    NARCIS (Netherlands)

    Thimm, B.W.; Hofmann, S.; Schneider, P.; Carretta, R.; Müller, R.

    2012-01-01

    Computed tomography (CT) represents a truly three-dimensional (3D) imaging technique that can provide high-resolution images on the cellular level. Thus, one approach to detect single cells is X-ray absorption-based CT, where cells are labeled with a dense, opaque material providing the required

  6. High-resolution surface wave tomography of the European crust and uppermost mantle from ambient seismic noise

    Science.gov (United States)

    Lu, Yang; Stehly, Laurent; Paul, Anne; AlpArray Working Group

    2018-05-01

    Taking advantage of the large number of seismic stations installed in Europe, in particular in the greater Alpine region with the AlpArray experiment, we derive a new high-resolution 3-D shear-wave velocity model of the European crust and uppermost mantle from ambient noise tomography. The correlation of up to four years of continuous vertical-component seismic recordings from 1293 broadband stations (10° W-35° E, 30° N-75° N) provides Rayleigh wave group velocity dispersion data in the period band 5-150 s at more than 0.8 million virtual source-receiver pairs. Two-dimensional Rayleigh wave group velocity maps are estimated using adaptive parameterization to accommodate the strong heterogeneity of path coverage. A probabilistic 3-D shear-wave velocity model, including probability densities for the depth of layer boundaries and S-wave velocity values, is obtained by non-linear Bayesian inversion. A weighted average of the probabilistic model is then used as starting model for the linear inversion step, providing the final Vs model. The resulting S-wave velocity model and Moho depth are validated by comparison with previous geophysical studies. Although surface-wave tomography is weakly sensitive to layer boundaries, vertical cross-sections through our Vs model and the associated probability of presence of interfaces display striking similarities with reference controlled-source (CSS) and receiver-function sections across the Alpine belt. Our model even provides new structural information such as a ˜8 km Moho jump along the CSS ECORS-CROP profile that was not imaged by reflection data due to poor penetration across a heterogeneous upper crust. Our probabilistic and final shear wave velocity models have the potential to become new reference models of the European crust, both for crustal structure probing and geophysical studies including waveform modeling or full waveform inversion.

  7. Highly resolving computerized tomography

    International Nuclear Information System (INIS)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions. (BWU) [de

  8. Highly resolving computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions.

  9. Active disease and residual damage in treated Wegener's granulomatosis: an observational study using pulmonary high-resolution computed tomography

    International Nuclear Information System (INIS)

    Komocsi, Andras; Reuter, Michael; Heller, Martin; Murakoezi, Henriette; Gross, Wolfgang L.; Schnabel, Armin

    2003-01-01

    The purpose of this study was to determine to what extent high-resolution computed tomography (HRCT) of the lungs can distinguish active inflammatory disease from inactive cicatricial disease in patients treated for Wegener's granulomatosis (WG). Twenty-eight WG patients with active pulmonary disease underwent a first HRCT examination immediately before standard immunosuppressive treatment and a second examination after clinical remission had been achieved. Lesions remaining after treatment were categorized as residual damage and were compared with findings during active disease to see by what features active and cicatricial disease can be distinguished. During active disease 17 patients had nodules/masses, 12 had ground-glass opacities, 6 had septal lines and 6 had non-septal lines. After treatment, ground-glass opacities had resolved completely. Nodules/masses had resolved in 8 patients and had diminished in 7 patients. Residual nodules were distinguished from nodules/masses in active disease by lack of cavitation and a diameter of mostly <15 mm. In one-third of patients lines resolved, but in 8 instances new lines evolved during immunosuppression. During a follow-up period of a median 26.5 months (range 20.0-33.8), patients with residual nodules or lines had no more relapses than patients with completely cleared lungs. Treated pulmonary WG leaves substantial residual damage. High-resolution CT does assist in the distinction between active and inactive lesions. Ground-glass opacities, cavitating nodules/masses and masses measuring more than 3 cm represent active disease ordinarily. Non-cavitary small nodules and septal or non-septal lines can be either active or cicatricial lesions. The nature of these lesions needs to be clarified by longitudinal observation. (orig.)

  10. Clinical, pathological, and radiological characteristics of solitary ground-glass opacity lung nodules on high-resolution computed tomography

    Directory of Open Access Journals (Sweden)

    Qiu ZX

    2016-09-01

    Full Text Available Zhi-Xin Qiu,1 Yue Cheng,1 Dan Liu,1 Wei-Ya Wang,2 Xia Wu,2 Wei-Lu Wu,2 Wei-Min Li1,2 1Department of Respiratory Medicine, 2Department of Pathology, West China Hospital, Sichuan University, Chengdu, People’s Republic of China Background: Lung nodules are being detected at an increasing rate year by year with high-resolution computed tomography (HRCT being widely used. Ground-glass opacity nodule is one of the special types of pulmonary nodules that is confirmed to be closely associated with early stage of lung cancer. Very little is known about solitary ground-glass opacity nodules (SGGNs. In this study, we analyzed the clinical, pathological, and radiological characteristics of SGGNs on HRCT.Methods: A total of 95 resected SGGNs were evaluated with HRCT scan. The clinical, pathological, and radiological characteristics of these cases were analyzed.Results: Eighty-one adenocarcinoma and 14 benign nodules were observed. The nodules included 12 (15% adenocarcinoma in situ (AIS, 14 (17% minimally invasive adenocarcinoma (MIA, and 55 (68% invasive adenocarcinoma (IA. No patients with recurrence till date have been identified. The positive expression rates of anaplastic lymphoma kinase and ROS-1 (proto-oncogene tyrosine-protein kinase ROS were only 2.5% and 8.6%, respectively. The specificity and accuracy of HRCT of invasive lung adenocarcinoma were 85.2% and 87.4%. The standard uptake values of only two patients determined by 18F-FDG positron emission tomography/computed tomography (PET/CT were above 2.5. The size, density, shape, and pleural tag of nodules were significant factors that differentiated IA from AIS and MIA. Moreover, the size, shape, margin, pleural tag, vascular cluster, bubble-like sign, and air bronchogram of nodules were significant determinants for mixed ground-glass opacity nodules (all P<0.05.Conclusion: We analyzed the clinical, pathological, and radiological characteristics of SGGNs on HRCT and found that the size, density

  11. High-Resolution Body Wave Tomography of the Ross Sea Embayment, Antarctica

    Science.gov (United States)

    White-Gaynor, A.; Nyblade, A.; Wiens, D. A.; Aster, R. C.; Gerstoft, P.; Bromirski, P. D.; Stephen, R. A.

    2017-12-01

    The West Antarctic Rift System (WARS) is one of the least understood continental rift system on the planet. The 1000 km wide WARS includes the Ross Sea Embayment between Marie Byrd Land and the Transantarctic Mountains (TAMS). Active volcanism on Ross Island continues to challenge our understanding of the generally quiescent rift system. Previous regional-scale body wave tomographic investigations have identified areas of low seismic wave speeds to 200 km depth beneath Ross Island. However, the spatial extent of the low velocity structure across the entirety of the WARS remains poorly constrained due to the insufficient resolution of upper mantle structure under the Ross Sea Embayment away from Ross Island. We utilize teleseismic P wave observations recorded on the RIS/DRIS network, which consists of 34 seismometers deployed across the Ross Ice Shelf, along with data from nearby POLENET and TAMSEIS stations to better resolve this region. Relative P wave travel time residuals from 1300 teleseismic events, obtained using a multichannel cross-correlation method, have been inverted for a seismic velocity model of the upper mantle throughout the Ross Sea Embayment. Our results suggest that the low wave speed structure under Ross Island extends roughly halfway across the Embayment and south along the Transantarctic Mountains. This observation is consistent with a two-phase rifting history for the WARS in which broad, late Cretaceous rifting between Marie Byrd Land and the TAMS transitioned to more focused rifting along the TAMS margin in the Cenozoic.

  12. Imaging tissues for biomedical research using the high-resolution micro-tomography system nanotom® m

    Science.gov (United States)

    Deyhle, Hans; Schulz, Georg; Khimchenko, Anna; Bikis, Christos; Hieber, Simone E.; Jaquiery, Claude; Kunz, Christoph; Müller-Gerbl, Magdalena; Höchel, Sebastian; Saxer, Till; Stalder, Anja K.; Ilgenstein, Bernd; Beckmann, Felix; Thalmann, Peter; Buscema, Marzia; Rohr, Nadja; Holme, Margaret N.; Müller, Bert

    2016-10-01

    Micro computed tomography (mCT) is well established in virtually all fields of biomedical research, allowing for the non-destructive volumetric visualization of tissue morphology. A variety of specimens can be investigated, ranging from soft to hard tissue to engineered structures like scaffolds. Similarly, the size of the objects of interest ranges from a fraction of a millimeter to several tens of centimeters. While synchrotron radiation-based μCT still offers unrivaled data quality, the ever-improving technology of cathodic tube-based machines offers a valuable and more accessible alternative. The Biomaterials Science Center of the University of Basel operates a nanotomOR m (phoenix|x-ray, GE Sensing and Inspection Technologies GmbH, Wunstorf, Germany), with a 180 kV source and a minimal spot size of about 0.9 μm. Through the adjustable focus-specimen and focus-detector distances, the effective pixel size can be adjusted from below 500 nm to about 80 μm. On the high-resolution side, it is for example possible to visualize the tubular network in sub-millimeter thin dentin specimens. It is then possible to locally extract parameters such as tubule diameter, density, or alignment, giving information on cell movements during tooth formation. On the other side, with a horizontal shift of the 3,072 pixels x 2,400 pixels detector, specimens up to 35 cm in diameter can be scanned. It is possible, for example, to scan an entire human knee, albeit with inferior resolution. Lab source μCT machines are thus a powerful and flexible tool for the advancement of biomedical research, and a valuable and more accessible alternative to synchrotron radiation facilities.

  13. High-resolution Fourier-Domain Optical Coherence Tomography and Microperimetric Findings After Macula-off Retinal Detachment Repair

    Science.gov (United States)

    Smith, Allison J.; Telander, David G.; Zawadzki, Robert J.; Choi, Stacey S.; Morse, Lawrence S.; Werner, John S.; Park, Susanna S.

    2009-01-01

    Objective To evaluate the morphologic changes in the macula of subjects with repaired macula-off retinal detachment (RD) using high-resolution Fourier-domain optical coherence tomography (FD OCT) and to perform functional correlation in a subset of patients using microperimetry (MP-1). Design Prospective observational case series. Participants Seventeen eyes from 17 subjects who had undergone anatomically successful repair for macula-off, rhegmatogenous RD at least 3 months earlier and without visually significant maculopathy on funduscopy. Methods FD OCT with axial and transverse resolution of 4.5 μm and 10 to 15 μm, respectively, was used to obtain rapid serial B-scans of the macula, which were compared with that from Stratus OCT. The FD OCT B-scans were used to create a 3-dimensional volume, from which en face C-scans were created. Among 11 patients, MP-1 was performed to correlate morphologic changes with visual function. Main Outcome Measures Stratus OCT scans, FD OCT scans, and MP-1 data. Results Stratus OCT and FD OCT images of the macula were obtained 3 to 30 months (mean 7 months) postoperatively in all eyes. Although Stratus OCT revealed photoreceptor disruption in 2 eyes (12%), FD OCT showed photoreceptor disruption in 13 eyes (76%). This difference was statistically significant (Pmacula-off RD repair is a common abnormality in the macula that is detected better with FD OCT than Stratus OCT. A good correlation between MP-1 abnormality and presence of photoreceptor disruption or subretinal fluid on FD OCT demonstrates that these anatomic abnormalities contribute to decreased visual function after successful repair. PMID:18672289

  14. High-resolution computed tomography versus chest radiography in the diagnosis of interstitial lung disease in systemic sclerosis

    International Nuclear Information System (INIS)

    Azevedo, Ana Beatriz Cordeiro de; Calderaro, Debora; Moreira, Caio; Guimaraes, Silvana Mangeon Meirelles; Tavares Junior, Wilson Campos; Leao Filho, Hilton Muniz; Andrade, Diego Correa de; Ferreira, Cid Sergio; Vieira, Jose Nelson Mendes

    2005-01-01

    Objective: To compare the accuracy of high-resolution computed tomography (HRCT) with chest radiography in the diagnosis of interstitial lung disease in systemic sclerosis (SSc). Materials And Methods: HRCT scans and chest radiographs in postero-anterior and lateral views were performed in 34 patients with systemic sclerosis, according to the American College of Rheumatology preliminary criteria for the diagnosis of SSc. The prevalence of radiological findings suggestive of interstitial lung disease in SSc seen on both imaging methods was compared. Results: Interstitial disease was observed on HRCT images of 31 patients (91%) and in the chest radiographs of 16 patients (47%). The most frequent findings observed on HRCT were septal lines (74%), honeycombing (56%) and parenchymal bands (26%). Chest radiographs showed reticular areas of attenuation in 11 patients (32%) and parenchymal distortion in 12% of the patients. In 18 patients (53%) with normal chest radiographs HRCT showed septal lines in 55%, ground glass in 44%, honeycombing in 38.5% and cysts in 33%. Conclusion: HRCT is more sensitive than chest radiography in the evaluation of incipient interstitial lung involvement in patients with SSc and can provide a justification for immunosuppressive therapy in patients with early disease. (author)

  15. Clinical Impact of Emphysema Evaluated by High-Resolution Computed Tomography on Idiopathic Pulmonary Fibrosis Diagnosed by Surgical Lung Biopsy.

    Science.gov (United States)

    Kohashi, Yasuo; Arai, Toru; Sugimoto, Chikatoshi; Tachibana, Kazunobu; Akira, Masanori; Kitaichi, Masanori; Hayashi, Seiji; Inoue, Yoshikazu

    2016-01-01

    The prognosis of combined cases of pulmonary fibrosis and emphysema is unresolved partially because radiological differentiation between usual interstitial pneumonia and nonspecific interstitial pneumonia is difficult in coexisting emphysema cases. The purpose of this study was to clarify the clinical impact of emphysema on the survival of patients with idiopathic pulmonary fibrosis (IPF). One hundred and seven patients with interstitial lung diseases were diagnosed by surgical lung biopsies between 2006 and 2012, and 47 patients were diagnosed with IPF through multidisciplinary discussion. Emphysema on high-resolution computed tomography scans was evaluated semiquantitatively by visual scoring. Eight out of the 47 IPF patients showed a higher emphysema score (>3) and were diagnosed to have IPF-emphysema. The median survival time of patients with IPF-emphysema (1,734 days) from the initial diagnosis was significantly shorter than that of patients with IPF alone (2,229 days) by Kaplan-Meier analysis (p = 0.007, log-rank test). Univariate Cox proportional hazard regression analyses revealed that a higher total emphysema score (>3.0) was a significantly poor prognostic factor in addition to Krebs von den Lungen-6, surfactant protein-D, arterial oxygen tension, percent forced vital capacity, and percent diffusing capacity of carbon monoxide (%DLCO). Multivariate Cox proportional hazard regression analyses with the stepwise method showed that higher total emphysema score (>3) and %DLCO were significantly poor prognostic factors. The prognosis of IPF-emphysema was significantly worse than that of IPF alone. © 2016 S. Karger AG, Basel.

  16. Changes in structural lung disease in cystic fibrosis children over 4 years as evaluated by high-resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Carpio, Carlos; Alvarez-Sala, Rodolfo; Prados, Concepcion [University Hospital La Paz, La Paz Hospital Research Institute, Department of Respiratory Medicine, Madrid (Spain); Albi, Gustavo [Nino de Jesus Children' s Hospital, Department of Radiology, Madrid (Spain); Rayon-Aledo, Jose Carlos; Caballero, Paloma [University Hospital La Princesa, Department of Radiology, Madrid (Spain); Giron, Rosa [University Hospital La Princesa, Department of Respiratory Medicine, Madrid (Spain)

    2015-12-15

    To compare the worsening of structural lung disease on high-resolution computed tomography (HRCT) with changes in spirometry results in cystic fibrosis (CF) patients, and analyse factors associated with the worsening of structural lung disease over time. A total of 31 CF subjects (mean age 11.03 ± 3.67 years old) were prospectively evaluated by two HRCT and spirometry tests performed 4 years apart. HRCT abnormalities were scored using the Bhalla scoring system. Comparisons between changes on HRCT and spirometry were made for all patients, and also for groups categorized by age, sex, genotypic alterations and lung obstruction. The mean HRCT Bhalla scoring, forced expiratory volume in 1 s (FEV{sub 1} %pred.) and forced vital capacity (FVC %pred.) were 7.92 ± 3.59, 87.76 ± 20.52 and 96.54 ± 15.12, respectively. There was a significant deterioration in the Bhalla score (p < 0.01) and in certain categories: severity of bronchiectasis, peribronchial thickening, mucous plugging and bronchial divisions. Females had a more pronounced worsening of the Bhalla score than males (p = 0.048). No change over time was found in FEV{sub 1} and FVC. Only sex was associated with a deterioration in HRCT. HRCT Bhalla scoring changes statistically significantly over 4 years, but spirometry results do not. Worsening on HRCT is more evident in females. (orig.)

  17. Changes in structural lung disease in cystic fibrosis children over 4 years as evaluated by high-resolution computed tomography

    International Nuclear Information System (INIS)

    Carpio, Carlos; Alvarez-Sala, Rodolfo; Prados, Concepcion; Albi, Gustavo; Rayon-Aledo, Jose Carlos; Caballero, Paloma; Giron, Rosa

    2015-01-01

    To compare the worsening of structural lung disease on high-resolution computed tomography (HRCT) with changes in spirometry results in cystic fibrosis (CF) patients, and analyse factors associated with the worsening of structural lung disease over time. A total of 31 CF subjects (mean age 11.03 ± 3.67 years old) were prospectively evaluated by two HRCT and spirometry tests performed 4 years apart. HRCT abnormalities were scored using the Bhalla scoring system. Comparisons between changes on HRCT and spirometry were made for all patients, and also for groups categorized by age, sex, genotypic alterations and lung obstruction. The mean HRCT Bhalla scoring, forced expiratory volume in 1 s (FEV 1 %pred.) and forced vital capacity (FVC %pred.) were 7.92 ± 3.59, 87.76 ± 20.52 and 96.54 ± 15.12, respectively. There was a significant deterioration in the Bhalla score (p < 0.01) and in certain categories: severity of bronchiectasis, peribronchial thickening, mucous plugging and bronchial divisions. Females had a more pronounced worsening of the Bhalla score than males (p = 0.048). No change over time was found in FEV 1 and FVC. Only sex was associated with a deterioration in HRCT. HRCT Bhalla scoring changes statistically significantly over 4 years, but spirometry results do not. Worsening on HRCT is more evident in females. (orig.)

  18. High-resolution computed tomography of the chest in children with cystic fibrosis: support for use as an outcome surrogate

    Energy Technology Data Exchange (ETDEWEB)

    Brody, A.S. [Departments of Radiology and Pediatrics, Children`s Hospital Medical Center, Cincinnati, OH (United States)]|[University of Cincinnati School of Medicine, Children`s Hospital Medical Center, Cincinnati, OH (United States)]|[Department of Radiology, Cincinnati, OH (United States); Molina, P.L. [Department of Radiology, University of North Carolina at Chapel Hill, North Carolina (United States); Klein, J.S. [Department of Radiology, University of Vermont, Burlington, Vermont (United States); Rothman, B.S. [University of Cincinnati School of Medicine, Children`s Hospital Medical Center, Cincinnati, OH (United States); Ramagopal, M.; Swartz, D.R. [Department of Pediatrics, University of Vermont, Burlington, Vermont (United States)

    1999-10-01

    Background. Outcome surrogates are indicators that reflect, rather than directly measure, patient benefit. In order to provide useful results, however, outcome surrogates must be carefully chosen and must meet specific criteria. Objective. To support development of high-resolution computed tomography (HRCT) as an outcome surrogate in cystic fibrosis (CF) by demonstrating the ability of HRCT to show short-term improvement in the appearance of the lungs in children with CF. Materials and methods. HRCT was performed at admission and after discharge on 8 children during 15 admissions for acute pulmonary exacerbation of CF. Three radiologists scored each study separately, then compared admission and discharge pairs. Results. HRCT scores improved in 13/15 admissions. Mean score decreased from 25 to 22. The decrease was significant (P = 0.014). Comparison of admission and discharge scans showed improvement in peribronchial thickening (P = 0.007), mucous plugging (P = 0.002), and overall appearance (P = 0.025). Conclusion. HRCT has the potential to be a useful outcome surrogate in CF. A necessary attribute of an outcome surrogate is that it improves rapidly with effective therapy. Despite widespread belief among radiologists and pulmonologists that HRCT meets this criterion, no previous report has demonstrated this ability in children. These findings support further development of HRCT as an outcome surrogate in children with CF. (orig.) With 2 figs., 2 tabs., 18 refs.

  19. Comparison of initial high resolution computed tomography features in viral pneumonia between metapneumovirus infection and severe acute respiratory syndrome

    International Nuclear Information System (INIS)

    Wong, Cheuk Kei Kathy; Lai, Vincent; Wong, Yiu Chung

    2012-01-01

    Objective: To review and compare initial high resolution computed tomography (HRCT) findings in patients with metapneumovirus pneumonia and severe acute respiratory syndrome (SARS-Coronovirus). Materials and methods: 4 cases of metapneumovirus pneumonia (mean age of 52.3 years) in an institutional outbreak (Castle Peak Hospital) in 2008 and 38 cases of SARS-coronovirus (mean age of 39.6 years) admitted to Tuen Mun hospital during an epidemic outbreak in 2003 were included. HRCT findings of the lungs for all patients were retrospectively reviewed by two independent radiologists. Results: In the metapneumovirus group, common HRCT features were ground glass opacities (100%), consolidation (100%), parenchymal band (100%), bronchiectasis (75%). Crazy paving pattern was absent. They were predominantly subpleural and basal in location and bilateral involvement was observed in 50% of patients. In the SARS group, common HRCT features were ground glass opacities (92.1%), interlobular septal thickening (86.8%), crazy paving pattern (73.7%) and consolidation (68%). Bronchiectasis was not seen. Majority of patient demonstrated segmental or lobar in distribution and bilateral involvement was observed in 44.7% of patients. Pleural effusion and lymphadenopathy were of consistent rare features in both groups. Conclusion: Ground glass opacities, interlobular septal thickening and consolidations were consistent HRCT manifestations in both metapneumovirus infection and SARS. The presence of bronchiectasis (0% in SARS) may point towards metapneumovirus while crazy paving pattern is more suggestive of SARS.

  20. High-resolution computed tomography of the chest in children with cystic fibrosis: support for use as an outcome surrogate

    International Nuclear Information System (INIS)

    Brody, A.S.; Molina, P.L.; Klein, J.S.; Rothman, B.S.; Ramagopal, M.; Swartz, D.R.

    1999-01-01

    Background. Outcome surrogates are indicators that reflect, rather than directly measure, patient benefit. In order to provide useful results, however, outcome surrogates must be carefully chosen and must meet specific criteria. Objective. To support development of high-resolution computed tomography (HRCT) as an outcome surrogate in cystic fibrosis (CF) by demonstrating the ability of HRCT to show short-term improvement in the appearance of the lungs in children with CF. Materials and methods. HRCT was performed at admission and after discharge on 8 children during 15 admissions for acute pulmonary exacerbation of CF. Three radiologists scored each study separately, then compared admission and discharge pairs. Results. HRCT scores improved in 13/15 admissions. Mean score decreased from 25 to 22. The decrease was significant (P = 0.014). Comparison of admission and discharge scans showed improvement in peribronchial thickening (P = 0.007), mucous plugging (P = 0.002), and overall appearance (P = 0.025). Conclusion. HRCT has the potential to be a useful outcome surrogate in CF. A necessary attribute of an outcome surrogate is that it improves rapidly with effective therapy. Despite widespread belief among radiologists and pulmonologists that HRCT meets this criterion, no previous report has demonstrated this ability in children. These findings support further development of HRCT as an outcome surrogate in children with CF. (orig.)

  1. High-resolution Computed Tomography Findings of H1N1 Influenza-Associated Pneumonia in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Chan; Choi, Song; Kim, Jin Woong; Lim, Hyo Soon [Dept. of Radiology, Chonnam National University Hospital, Chonnam National University School of Medicine, Kwangju (Korea, Republic of); Seon, Hyung Joo; Shin, Sang Soo [Dept. of Radiology, Chonnam National University Hospital, Chonnam National University School of Medicine, Kwangju (Korea, Republic of); Kim, Yun Hyeon; Park, Kyung Hwa [Dept. of Internal Medicine, Chonnam National University Hospital, Chonnam National University School of Medicine, Kwangju (Korea, Republic of)

    2011-04-15

    To evaluate and compare the high-resolution computed tomography (HRCT) findings of patients with H1N1 influenza-associated pneumonia compared usual community acquired pneumonia (CAP), to determine whether there were any useful common HRCT findings predicting their prognosis. HRCT findings of 31 patients (M:F = 16:15, mean age 42 yrs) with Influenza A (H1N1) infection were retrospectively reviewed for abnormal HRCT findings and compared to HRCT findings of CAP in matched patients. Patients were matched according to age and sex, from 2009 to January 2010. The predominant HRCT findings of pneumonia consisted of areas of consolidation and/or groundglass opacity (GGO) which showed no statistically significant differences when comparing the two groups. However, the abnormalities of H1N1-related pneumonia showed higher bilaterality and multilobar or multisegmental involvement compared with CAP (p < 0.05). Internal low attenuation or air-densities in pulmonary infiltration /or lymphadenopathy was observed only in patients with CAP (p < 0.05). HRCT findings in 8 patients with poor clinical outcome had bilaterality (p=0.015), multilobar, and multisegmental involvement. The predominant HRCT findings of H1N1-related pneumonia were areas of consolidation and/or GGO. In addition, H1N1-related pneumonia showed higher bilaterality or multilobar/multisegmental involvement compared with CAP. The patients who presented bilaterality had a worse clinical outcome.

  2. High-resolution Computed Tomography in the Diagnosis of Otosclerosis in Taiwan

    Directory of Open Access Journals (Sweden)

    Tsung-Lun Lee

    2009-10-01

    Conclusion: HRCT has high specificity (100% but low sensitivity (46% for the diagnosis of otosclerosis in Taiwanese patients despite progress in radiology. The low image positive rate we found, compared with that in Western literature, may stem from a greater percentage of inactive otosclerosis. [J Chin Med Assoc 2009;72(10:527–532

  3. High-resolution computed tomography findings of pulmonary tuberculosis in lung transplant recipients

    Directory of Open Access Journals (Sweden)

    Irai Luis Giacomelli

    Full Text Available ABSTRACT Objective: Respiratory infections constitute a major cause of morbidity and mortality in solid organ transplant recipients. The incidence of pulmonary tuberculosis is high among such patients. On imaging, tuberculosis has various presentations. Greater understanding of those presentations could reduce the impact of the disease by facilitating early diagnosis. Therefore, we attempted to describe the HRCT patterns of pulmonary tuberculosis in lung transplant recipients. Methods: From two hospitals in southern Brazil, we collected the following data on lung transplant recipients who developed pulmonary tuberculosis: gender; age; symptoms; the lung disease that led to transplantation; HRCT pattern; distribution of findings; time from transplantation to pulmonary tuberculosis; and mortality rate. The HRCT findings were classified as miliary nodules; cavitation and centrilobular nodules with a tree-in-bud pattern; ground-glass attenuation with consolidation; mediastinal lymph node enlargement; or pleural effusion. Results: We evaluated 402 lung transplant recipients, 19 of whom developed pulmonary tuberculosis after transplantation. Among those 19 patients, the most common HRCT patterns were ground-glass attenuation with consolidation (in 42%; cavitation and centrilobular nodules with a tree-in-bud pattern (in 31.5%; and mediastinal lymph node enlargement (in 15.7%. Among the patients with cavitation and centrilobular nodules with a tree-in-bud pattern, the distribution was within the upper lobes in 66.6%. No pleural effusion was observed. Despite treatment, one-year mortality was 47.3%. Conclusions: The predominant HRCT pattern was ground-glass attenuation with consolidation, followed by cavitation and centrilobular nodules with a tree-in-bud pattern. These findings are similar to those reported for immunocompetent patients with pulmonary tuberculosis and considerably different from those reported for AIDS patients with the same disease.

  4. High-resolution computed tomography findings of pulmonary tuberculosis in lung transplant recipients

    Energy Technology Data Exchange (ETDEWEB)

    Giacomelli, Irai Luis; Schuhmacher Neto, Roberto; Nin, Carlos Schuller; Cassano, Priscilla de Souza; Pereira, Marisa; Moreira, Jose da Silva; Nascimento, Douglas Zaione; Hochhegger, Bruno, E-mail: iraigiacomelli@gmail.com [Complexo Hospitalar Santa Casa de Porto Alegre, RS (Brazil)

    2017-07-15

    Objective: Respiratory infections constitute a major cause of morbidity and mortality in solid organ transplant recipients. The incidence of pulmonary tuberculosis is high among such patients. On imaging, tuberculosis has various presentations. Greater understanding of those presentations could reduce the impact of the disease by facilitating early diagnosis. Therefore, we attempted to describe the HRCT patterns of pulmonary tuberculosis in lung transplant recipients. Methods: From two hospitals in southern Brazil, we collected the following data on lung transplant recipients who developed pulmonary tuberculosis: gender; age; symptoms; the lung disease that led to transplantation; HRCT pattern; distribution of findings; time from transplantation to pulmonary tuberculosis; and mortality rate. The HRCT findings were classified as miliary nodules; cavitation and centrilobular nodules with a tree-in-bud pattern; ground-glass attenuation with consolidation; mediastinal lymph node enlargement; or pleural effusion. Results: We evaluated 402 lung transplant recipients, 19 of whom developed pulmonary tuberculosis after transplantation. Among those 19 patients, the most common HRCT patterns were ground-glass attenuation with consolidation (in 42%); cavitation and centrilobular nodules with a tree-in-bud pattern (in 31.5%); and mediastinal lymph node enlargement (in 15.7%). Among the patients with cavitation and centrilobular nodules with a tree-in-bud pattern, the distribution was within the upper lobes in 66.6%. No pleural effusion was observed. Despite treatment, one-year mortality was 47.3%. Conclusions: The predominant HRCT pattern was ground-glass attenuation with consolidation, followed by cavitation and centrilobular nodules with a tree-in-bud pattern. These findings are similar to those reported for immunocompetent patients with pulmonary tuberculosis and considerably different from those reported for AIDS patients with the same disease. (author)

  5. High-resolution computed tomography findings of pulmonary tuberculosis in lung transplant recipients.

    Science.gov (United States)

    Giacomelli, Irai Luis; Schuhmacher Neto, Roberto; Nin, Carlos Schuller; Cassano, Priscilla de Souza; Pereira, Marisa; Moreira, José da Silva; Nascimento, Douglas Zaione; Hochhegger, Bruno

    2017-01-01

    Respiratory infections constitute a major cause of morbidity and mortality in solid organ transplant recipients. The incidence of pulmonary tuberculosis is high among such patients. On imaging, tuberculosis has various presentations. Greater understanding of those presentations could reduce the impact of the disease by facilitating early diagnosis. Therefore, we attempted to describe the HRCT patterns of pulmonary tuberculosis in lung transplant recipients. From two hospitals in southern Brazil, we collected the following data on lung transplant recipients who developed pulmonary tuberculosis: gender; age; symptoms; the lung disease that led to transplantation; HRCT pattern; distribution of findings; time from transplantation to pulmonary tuberculosis; and mortality rate. The HRCT findings were classified as miliary nodules; cavitation and centrilobular nodules with a tree-in-bud pattern; ground-glass attenuation with consolidation; mediastinal lymph node enlargement; or pleural effusion. We evaluated 402 lung transplant recipients, 19 of whom developed pulmonary tuberculosis after transplantation. Among those 19 patients, the most common HRCT patterns were ground-glass attenuation with consolidation (in 42%); cavitation and centrilobular nodules with a tree-in-bud pattern (in 31.5%); and mediastinal lymph node enlargement (in 15.7%). Among the patients with cavitation and centrilobular nodules with a tree-in-bud pattern, the distribution was within the upper lobes in 66.6%. No pleural effusion was observed. Despite treatment, one-year mortality was 47.3%. The predominant HRCT pattern was ground-glass attenuation with consolidation, followed by cavitation and centrilobular nodules with a tree-in-bud pattern. These findings are similar to those reported for immunocompetent patients with pulmonary tuberculosis and considerably different from those reported for AIDS patients with the same disease.

  6. High-resolution emission tomography of small laboratory animals: physics and gamma-astronomy meet molecular biology

    International Nuclear Information System (INIS)

    Beekman, F.J.; Colijn, A.P.; Vastenhouw, B.; Wiegant, V.M.; Gerrits, M.A.F.M.

    2003-01-01

    Molecular imaging can be defined as the characterization and measurement of biological processes in living animals, model systems and humans at the cellular and molecular level using remote imaging detectors. An example concerns the mapping of the distributions of radioactively labeled molecules in laboratory animals which is of crucial importance for life sciences. Tomographic methods like Single Photon Emission Computed Tomography (SPECT) offer a possibility to visualize distributions of radioactively labeled molecules in living animals. Miniature tomography systems, derived from their clinical counterparts, but with a much higher image resolution are under development in several institutes. An example is U-SPECT that will be discussed in the present paper. Such systems are expected to accelerate several biomedical research procedures, the understanding of gene and protein function, as well as pharmaceutical development

  7. Utility of high-resolution computed tomography for predicting risk of sputum smear-negative pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Nakanishi, Masanori; Demura, Yoshiki; Ameshima, Shingo; Kosaka, Nobuyuki; Chiba, Yukio; Nishikawa, Satoshi; Itoh, Harumi; Ishizaki, Takeshi

    2010-01-01

    Background: To diagnose sputum smear-negative pulmonary tuberculosis (PTB) is difficult and the ability of high-resolution computed tomography (HRCT) for diagnosing PTB has remained unclear in the sputum smear-negative setting. We retrospectively investigated whether or not this imaging modality can predict risk for sputum smear-negative PTB. Methods: We used HRCT to examine the findings of 116 patients with suspected PTB despite negative sputum smears for acid-fast bacilli (AFB). We investigated their clinical features and HRCT-findings to predict the risk for PTB by multivariate analysis and a combination of HRCT findings by stepwise regression analysis. We then designed provisional HRCT diagnostic criteria based on these results to rank the risk of PTB and blinded observers assessed the validity and reliability of these criteria. Results: A positive tuberculin skin test alone among clinical laboratory findings was significantly associated with an increase of risk of PTB. Multivariate regression analysis showed that large nodules, tree-in-bud appearance, lobular consolidation and the main lesion being located in S1, S2, and S6 were significantly associated with an increased risk of PTB. Stepwise regression analysis showed that coexistence of the above 4 factors was most significantly associated with an increase in the risk for PTB. Ranking of the results using our HRCT diagnostic criteria by blinded observers revealed good utility and agreement for predicting PTB risk. Conclusions: Even in the sputum smear-negative setting, HRCT can predict the risk of PTB with good reproducibility and can select patients having a high probability of PTB.

  8. Utility of high-resolution computed tomography for predicting risk of sputum smear-negative pulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Masanori [Departments of Respiratory Medicine, Faculty of Medical Sciences, University of Fukui, 23 Shimoaizuki Eiheizi-cho, Fukui 910-1193 (Japan)], E-mail: mnakanishi@nifty.ne.jp; Demura, Yoshiki; Ameshima, Shingo [Departments of Respiratory Medicine, Faculty of Medical Sciences, University of Fukui, 23 Shimoaizuki Eiheizi-cho, Fukui 910-1193 (Japan); Kosaka, Nobuyuki [Departments of Radiology, Faculty of Medical Sciences, University of Fukui, 23 Shimoaizuki Eiheizi-cho, Fukui 910-1193 (Japan); Chiba, Yukio [Department of Respiratory Medicine, National Hospital Organization, Fukui Hospital, Tsuruga, Fukui 914-0195 (Japan); Nishikawa, Satoshi [Department of Radiology, National Hospital Organization, Fukui Hospital, Tsuruga, Fukui 914-0195 (Japan); Itoh, Harumi [Departments of Radiology, Faculty of Medical Sciences, University of Fukui, 23 Shimoaizuki Eiheizi-cho, Fukui 910-1193 (Japan); Ishizaki, Takeshi [Departments of Respiratory Medicine, Faculty of Medical Sciences, University of Fukui, 23 Shimoaizuki Eiheizi-cho, Fukui 910-1193 (Japan)

    2010-03-15

    Background: To diagnose sputum smear-negative pulmonary tuberculosis (PTB) is difficult and the ability of high-resolution computed tomography (HRCT) for diagnosing PTB has remained unclear in the sputum smear-negative setting. We retrospectively investigated whether or not this imaging modality can predict risk for sputum smear-negative PTB. Methods: We used HRCT to examine the findings of 116 patients with suspected PTB despite negative sputum smears for acid-fast bacilli (AFB). We investigated their clinical features and HRCT-findings to predict the risk for PTB by multivariate analysis and a combination of HRCT findings by stepwise regression analysis. We then designed provisional HRCT diagnostic criteria based on these results to rank the risk of PTB and blinded observers assessed the validity and reliability of these criteria. Results: A positive tuberculin skin test alone among clinical laboratory findings was significantly associated with an increase of risk of PTB. Multivariate regression analysis showed that large nodules, tree-in-bud appearance, lobular consolidation and the main lesion being located in S1, S2, and S6 were significantly associated with an increased risk of PTB. Stepwise regression analysis showed that coexistence of the above 4 factors was most significantly associated with an increase in the risk for PTB. Ranking of the results using our HRCT diagnostic criteria by blinded observers revealed good utility and agreement for predicting PTB risk. Conclusions: Even in the sputum smear-negative setting, HRCT can predict the risk of PTB with good reproducibility and can select patients having a high probability of PTB.

  9. Spectrum of high resolution computed tomography findings in occupational lung disease: experience in a tertiary care institute.

    Science.gov (United States)

    Bhawna, Satija; Ojha, U C; Kumar, Sanyal; Gupta, Rajiv; Gothi, Dipti; Pal, R S

    2013-01-01

    To study the spectrum of high resolution computed tomography (HRCT) findings in occupational lung disease in industrial workers and to assess the utility of International classification of HRCT for occupational and environmental respiratory diseases (ICHOERD). Retrospective analysis of radiological data (radiographs and computed tomography chest scans) gathered over a period of 3 years (January 2010- December 2012) of industrial workers in an organised sector who presented with respiratory complaints. The HRCT findings were evaluated using ICHOERD. There were 5 females and 114 males in the study, with a mean age of 49 years. These workers were exposed to different harmful agents including silica, asbestos, cotton dust, metal dust, iron oxide, organic dust, rubber fumes, plastic fumes, acid fumes, and oil fumes. There were 10 smokers in the study. The radiograph of chest was normal in 53 patients. 46% of these normal patients (21.8% of total) demonstrated positive findings on HRCT. When the radiograph was abnormal, HRCT provided more accurate information and excluded the other diagnosis. The HRCT findings were appropriately described using the ICHOERD. Bronchiectasis was the most common finding (44.5%) with mild central cylindrical bronchiectasis as the most common pattern. Pleural thickening was seen in 41 patients (34.5%). Enlarged hilar or mediastinal lymphnodes were seen in 10 patients (8.4%) with egg-shell calcification in 1 patient exposed to silica. Bronchogenic carcinoma was seen in 1 patient exposed to asbestos. Occupational lung disease is a common work related condition in industrial workers even in the organized sector. Though chest radiograph is the primary diagnostic tool, HRCT is the undisputed Gold Standard for evaluation of these patients. Despite the disadvantage of radiation exposure, low dose CT may serve as an important tool for screening and surveillance. The ICHOERD is a powerful and reliable tool not only for diagnosis, but also for

  10. The dental cavities of equine cheek teeth: three-dimensional reconstructions based on high resolution micro-computed tomography

    Directory of Open Access Journals (Sweden)

    Kopke Susan

    2012-09-01

    Full Text Available Abstract Background Recent studies reported on the very complex morphology of the pulp system in equine cheek teeth. The continuous production of secondary dentine leads to distinct age-related changes of the endodontic cavity. Detailed anatomical knowledge of the dental cavities in all ages is required to explain the aetiopathology of typical equine endodontic diseases. Furthermore, data on mandibular and maxillary pulp systems is in high demand to provide a basis for the development of endodontic therapies. However, until now examination of the pulp cavity has been based on either sectioned teeth or clinical computed tomography. More precise results were expected by using micro-computed tomography with a resolution of about 0.1 mm and three-dimensional reconstructions based on previous greyscale analyses and histological verification. The aim of the present study was to describe the physiological configurations of the pulp system within a wide spectrum of tooth ages. Results Maxillary teeth: All morphological constituents of the endodontic cavity were present in teeth between 4 and 16 years: Triadan 06s displayed six pulp horns and five root canals, Triadan 07-10s five pulp horns and four root canals and Triadan 11s seven pulp horns and four to six root canals. A common pulp chamber was most frequent in teeth ≤5 years, but was found even in a tooth of 9 years. A large variety of pulp configurations was observed within 2.5 and 16 years post eruption, but most commonly a separation into mesial and distal pulp compartments was seen. Maxillary cheek teeth showed up to four separate pulp compartments but the frequency of two, three and four pulp compartments was not related to tooth age (P > 0.05. In Triadan 06s, pulp horn 6 was always connected to pulp horns 1 and 3 and root canal I. In Triadan 11s, pulp horns 7 and 8 were present in variable constitutions. Mandibular teeth: A common pulp chamber was present in teeth up to 15 years, but most

  11. Spectrum of High Resolution Computed Tomography Findings in Occupational Lung Disease: Experience in a Tertiary Care Institute

    Directory of Open Access Journals (Sweden)

    Satija Bhawna

    2013-01-01

    Full Text Available Objective: To study the spectrum of high resolution computed tomography (HRCT findings in occupational lung disease in industrial workers and to assess the utility of International classification of HRCT for occupational and environmental respiratory diseases (ICHOERD. Materials and Methods: Retrospective analysis of radiological data (radiographs and computed tomography chest scans gathered over a period of 3 years (January 2010- December 2012 of industrial workers in an organised sector who presented with respiratory complaints. The HRCT findings were evaluated using ICHOERD. Results: There were 5 females and 114 males in the study, with a mean age of 49 years. These workers were exposed to different harmful agents including silica, asbestos, cotton dust, metal dust, iron oxide, organic dust, rubber fumes, plastic fumes, acid fumes, and oil fumes. There were 10 smokers in the study. The radiograph of chest was normal in 53 patients. 46% of these normal patients (21.8% of total demonstrated positive findings on HRCT. When the radiograph was abnormal, HRCT provided more accurate information and excluded the other diagnosis. The HRCT findings were appropriately described using the ICHOERD. Bronchiectasis was the most common finding (44.5% with mild central cylindrical bronchiectasis as the most common pattern. Pleural thickening was seen in 41 patients (34.5%. Enlarged hilar or mediastinal lymphnodes were seen in 10 patients (8.4% with egg-shell calcification in 1 patient exposed to silica. Bronchogenic carcinoma was seen in 1 patient exposed to asbestos. Conclusions: Occupational lung disease is a common work related condition in industrial workers even in the organized sector. Though chest radiograph is the primary diagnostic tool, HRCT is the undisputed Gold Standard for evaluation of these patients. Despite the disadvantage of radiation exposure, low dose CT may serve as an important tool for screening and surveillance. The ICHOERD is a

  12. Bone-marrow densitometry: Assessment of marrow space of human vertebrae by single energy high resolution-quantitative computed tomography

    International Nuclear Information System (INIS)

    Peña, Jaime A.; Damm, Timo; Bastgen, Jan; Barkmann, Reinhard; Glüer, Claus C.; Thomsen, Felix; Campbell, Graeme M.

    2016-01-01

    Purpose: Accurate noninvasive assessment of vertebral bone marrow fat fraction is important for diagnostic assessment of a variety of disorders and therapies known to affect marrow composition. Moreover, it provides a means to correct fat-induced bias of single energy quantitative computed tomography (QCT) based bone mineral density (BMD) measurements. The authors developed new segmentation and calibration methods to obtain quantitative surrogate measures of marrow-fat density in the axial skeleton. Methods: The authors developed and tested two high resolution-QCT (HR-QCT) based methods which permit segmentation of bone voids in between trabeculae hypothesizing that they are representative of bone marrow space. The methods permit calculation of marrow content in units of mineral equivalent marrow density (MeMD). The first method is based on global thresholding and peeling (GTP) to define a volume of interest away from the transition between trabecular bone and marrow. The second method, morphological filtering (MF), uses spherical elements of different radii (0.1–1.2 mm) and automatically places them in between trabeculae to identify regions with large trabecular interspace, the bone-void space. To determine their performance, data were compared ex vivo to high-resolution peripheral CT (HR-pQCT) images as the gold-standard. The performance of the methods was tested on a set of excised human vertebrae with intact bone marrow tissue representative of an elderly population with low BMD. Results: 86% (GTP) and 87% (MF) of the voxels identified as true marrow space on HR-pQCT images were correctly identified on HR-QCT images and thus these volumes of interest can be considered to be representative of true marrow space. Within this volume, MeMD was estimated with residual errors of 4.8 mg/cm 3 corresponding to accuracy errors in fat fraction on the order of 5% both for GTP and MF methods. Conclusions: The GTP and MF methods on HR-QCT images permit noninvasive

  13. Bone-marrow densitometry: Assessment of marrow space of human vertebrae by single energy high resolution-quantitative computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Peña, Jaime A.; Damm, Timo; Bastgen, Jan; Barkmann, Reinhard; Glüer, Claus C., E-mail: glueer@rad.uni-kiel.de [Sektion Biomedizinische Bildgebung, Klinik für Radiologie und Neuroradiologie, Christian-Albrechts-Universität zu Kiel, Campus Kiel, Kiel 24118 (Germany); Thomsen, Felix [Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Universidad Nacional del Sur, Bahía Blanca 8000 (Argentina); Campbell, Graeme M. [Sektion Biomedizinische Bildgebung, Klinik für Radiologie und Neuroradiologie, Christian-Albrechts-Universität zu Kiel, Campus Kiel, Kiel 24118, Germany and Institut für Biomechanik, Technische Universität Hamburg-Harburg (TUHH), Hamburg 21073 (Germany)

    2016-07-15

    Purpose: Accurate noninvasive assessment of vertebral bone marrow fat fraction is important for diagnostic assessment of a variety of disorders and therapies known to affect marrow composition. Moreover, it provides a means to correct fat-induced bias of single energy quantitative computed tomography (QCT) based bone mineral density (BMD) measurements. The authors developed new segmentation and calibration methods to obtain quantitative surrogate measures of marrow-fat density in the axial skeleton. Methods: The authors developed and tested two high resolution-QCT (HR-QCT) based methods which permit segmentation of bone voids in between trabeculae hypothesizing that they are representative of bone marrow space. The methods permit calculation of marrow content in units of mineral equivalent marrow density (MeMD). The first method is based on global thresholding and peeling (GTP) to define a volume of interest away from the transition between trabecular bone and marrow. The second method, morphological filtering (MF), uses spherical elements of different radii (0.1–1.2 mm) and automatically places them in between trabeculae to identify regions with large trabecular interspace, the bone-void space. To determine their performance, data were compared ex vivo to high-resolution peripheral CT (HR-pQCT) images as the gold-standard. The performance of the methods was tested on a set of excised human vertebrae with intact bone marrow tissue representative of an elderly population with low BMD. Results: 86% (GTP) and 87% (MF) of the voxels identified as true marrow space on HR-pQCT images were correctly identified on HR-QCT images and thus these volumes of interest can be considered to be representative of true marrow space. Within this volume, MeMD was estimated with residual errors of 4.8 mg/cm{sup 3} corresponding to accuracy errors in fat fraction on the order of 5% both for GTP and MF methods. Conclusions: The GTP and MF methods on HR-QCT images permit noninvasive

  14. High-resolution computed tomography findings from adult patients with Influenza A (H1N1) virus-associated pneumonia

    International Nuclear Information System (INIS)

    Marchiori, Edson; Zanetti, Glaucia; Hochhegger, Bruno; Rodrigues, Rosana Souza; Fontes, Cristina Asvolinsque Pantaleao; Nobre, Luiz Felipe; Dias Mancano, Alexandre; Meirelles, Gustavo; Irion, Klaus Loureiro

    2010-01-01

    Objective: The aim of this study was to assess the high-resolution computed tomography (HRCT) findings at presentation in patients diagnosed with Influenza A (H1N1) virus-associated pneumonia. Materials and methods: We reviewed the HRCT findings from 20 patients diagnosed with Influenza A (H1N1) and compared their HRCT scans with chest radiographs, obtained on the same day. The imaging studies were obtained 4-9 days after the onset of symptoms. The patients included 11 men and 9 women (ages 24-62 years; mean 42.7 years). All patients had a body temperature greater than 100.4 deg. F (>38 deg. C), tachypnea, and cough. Other common symptoms included diarrhea (60%) and sore throat (30%). The radiographs and HRCT scans were reviewed independently by two observers who reached a consensus decision. Results: The predominant HRCT findings consisted of bilateral ground-glass opacities (n = 12), bilateral areas of consolidation (n = 2), or a mixed bilateral pattern of ground-glass opacities and areas of consolidation (n = 6). The abnormalities were bilateral in all of the 20 patients, had a predominantly sub-pleural distribution in 13 patients, and had a random distribution in the remaining 7 patients. The predominant radiographic findings were consolidations. Normal radiographs were found in 4 out of the 20 patients. Conclusion: HRCT may reveal parenchymal abnormalities in patients with Influenza A (H1N1) infection who have normal findings on radiographs. The predominant HRCT findings were bilateral, peripheral, ground-glass opacities and/or bilateral areas of consolidation. The patients who presented consolidations had more severe clinical course.

  15. Possible UIP pattern on high-resolution computed tomography is associated with better survival than definite UIP in IPF patients.

    Science.gov (United States)

    Salisbury, Margaret L; Tolle, Leslie B; Xia, Meng; Murray, Susan; Tayob, Nabihah; Nambiar, Anoop M; Schmidt, Shelley L; Lagstein, Amir; Myers, Jeffery L; Gross, Barry H; Kazerooni, Ella A; Sundaram, Baskaran; Chughtai, Aamer R; Martinez, Fernando J; Flaherty, Kevin R

    2017-10-01

    Idiopathic pulmonary fibrosis (IPF) is a progressive fibrosing lung disease of unknown etiology. Inter-society consensus guidelines on IPF diagnosis and management outline radiologic patterns including definite usual interstitial pneumonia (UIP), possible UIP, and inconsistent with UIP. We evaluate these diagnostic categories as prognostic markers among patients with IPF. Included subjects had biopsy-proven UIP, a multidisciplinary team diagnosis of IPF, and a baseline high-resolution computed tomography (HRCT). Thoracic radiologists assigned the radiologic pattern and documented the presence and extent of specific radiologic findings. The outcome of interest was lung transplant-free survival. IPF patients with a possible UIP pattern on HRCT had significantly longer Kaplan-Meier event-free survival compared to those with definite UIP pattern (5.21 and 3.57 years, respectively, p = 0.002). In a multivariable Cox proportional hazards model adjusted for baseline age, gender, %-predicted FVC, and %-predicted DLCO via the GAP Stage, extent of fibrosis (via the traction bronchiectasis score) and ever-smoker status, possible UIP pattern on HRCT (versus definite UIP) was associated with reduced hazard of death or lung transplant (HR = 0.42, CI 95% 0.23-0.78, p = 0.006). Radiologic diagnosis categories outlined by inter-society consensus guidelines is a widely-reported and potentially useful prognostic marker in IPF patients, with possible UIP pattern on HRCT associated with a favorable prognosis compared to definite UIP pattern, after adjusting for relevant covariates. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. High-resolution computed tomography findings of early mucinous adenocarcinomas and their pathologic characteristics in 22 surgically resected cases

    Energy Technology Data Exchange (ETDEWEB)

    Miyata, Naoko, E-mail: n.miyata@scchr.jp [Division of Thoracic Surgery, Shizuoka Cancer Center Hospital, 1007 Shimonagakubo, Nagaizumi, Sunto-gun, Shizuoka 411-8777 (Japan); Endo, Masahiro [Division of Diagnostic Radiology, Shizuoka Cancer Center Hospital (Japan); Nakajima, Takashi [Division of Pathology, Shizuoka Cancer Center Hospital (Japan); Kojima, Hideaki; Maniwa, Tomohiro; Takahashi, Shoji; Isaka, Mitsuhiro [Division of Thoracic Surgery, Shizuoka Cancer Center Hospital, 1007 Shimonagakubo, Nagaizumi, Sunto-gun, Shizuoka 411-8777 (Japan); Kameya, Toru [Division of Pathology, Shizuoka Cancer Center Hospital (Japan); Ohde, Yasuhisa [Division of Thoracic Surgery, Shizuoka Cancer Center Hospital, 1007 Shimonagakubo, Nagaizumi, Sunto-gun, Shizuoka 411-8777 (Japan)

    2015-05-15

    Highlights: • We clinicopathologically reviewed 22 cases of early mucinous adenocarcinoma. • Radiologically, all cases showed solid or part-solid nodules. • Lobular-bounded margins were observed in 7 cases. • The radiological features could be histologically attributed to mucin production. • One-third of the cases were preoperatively misdiagnosed as inflammatory nodules. - Abstract: Background: The pathological criteria of early-stage mucinous adenocarcinoma of the lung have recently been defined; however, its characteristic radiologic imaging findings are still poorly understood. Thus, this study aimed to clarify the radiologic and pathological findings of early-stage mucinous adenocarcinoma. Materials and methods: In this study, we clinicopathologically reviewed 22 cases of surgically resected mucinous adenocarcinoma in situ (AIS) and minimal invasive adenocarcinoma (MIA), and attempted to elucidate the characteristic radiologic features of early mucinous adenocarcinomas using high-resolution computed tomography (HRCT). Results: Radiologically, the mean value of the maximum diameter of 22 tumours was 2.1 cm (range, 1.0–2.9 cm). Based on the HRCT findings, the tumours were divided into part-solid ground glass nodules (n = 11) and solid nodules (n = 11). The mean CT attenuation value was 25.7 HU (range, 17–35 HU). All tumours, except 3 tumours pathologically diagnosed as AIS, showed air-containing features. According to the preoperative CT findings, 7 (35%) cases were diagnosed as inflammatory nodules. Of these, 4 cases had lobular-bounded margins, and 3 showed vaguely outlined ground glass shadows. Conclusion: The characteristic HRCT findings of mucinous AIS and MIA were solid or part-solid nodules with air-containing spaces. However, some AIS and MIA nodules showed lobular-bounded margins or marginally vaguely outlined ground glass shadows, and were difficult to differentiate from inflammatory nodules.

  17. High-resolution computed tomography findings of early mucinous adenocarcinomas and their pathologic characteristics in 22 surgically resected cases

    International Nuclear Information System (INIS)

    Miyata, Naoko; Endo, Masahiro; Nakajima, Takashi; Kojima, Hideaki; Maniwa, Tomohiro; Takahashi, Shoji; Isaka, Mitsuhiro; Kameya, Toru; Ohde, Yasuhisa

    2015-01-01

    Highlights: • We clinicopathologically reviewed 22 cases of early mucinous adenocarcinoma. • Radiologically, all cases showed solid or part-solid nodules. • Lobular-bounded margins were observed in 7 cases. • The radiological features could be histologically attributed to mucin production. • One-third of the cases were preoperatively misdiagnosed as inflammatory nodules. - Abstract: Background: The pathological criteria of early-stage mucinous adenocarcinoma of the lung have recently been defined; however, its characteristic radiologic imaging findings are still poorly understood. Thus, this study aimed to clarify the radiologic and pathological findings of early-stage mucinous adenocarcinoma. Materials and methods: In this study, we clinicopathologically reviewed 22 cases of surgically resected mucinous adenocarcinoma in situ (AIS) and minimal invasive adenocarcinoma (MIA), and attempted to elucidate the characteristic radiologic features of early mucinous adenocarcinomas using high-resolution computed tomography (HRCT). Results: Radiologically, the mean value of the maximum diameter of 22 tumours was 2.1 cm (range, 1.0–2.9 cm). Based on the HRCT findings, the tumours were divided into part-solid ground glass nodules (n = 11) and solid nodules (n = 11). The mean CT attenuation value was 25.7 HU (range, 17–35 HU). All tumours, except 3 tumours pathologically diagnosed as AIS, showed air-containing features. According to the preoperative CT findings, 7 (35%) cases were diagnosed as inflammatory nodules. Of these, 4 cases had lobular-bounded margins, and 3 showed vaguely outlined ground glass shadows. Conclusion: The characteristic HRCT findings of mucinous AIS and MIA were solid or part-solid nodules with air-containing spaces. However, some AIS and MIA nodules showed lobular-bounded margins or marginally vaguely outlined ground glass shadows, and were difficult to differentiate from inflammatory nodules

  18. Diagnostic accuracy for X-ray chest in interstitial lung disease as confirmed by high resolution computed tomography (HRCT) chest

    International Nuclear Information System (INIS)

    Afzal, F.; Raza, S.; Shafique, M.

    2017-01-01

    Objective: To determine the diagnostic accuracy of x-ray chest in interstitial lung disease as confirmed by high resolution computed tomography (HRCT) chest. Study Design: A cross-sectional validational study. Place and Duration of Study: Department of Diagnostic Radiology, Combined Military Hospital Rawalpindi, from Oct 2013 to Apr 2014. Material and Method: A total of 137 patients with clinical suspicion of interstitial lung disease (ILD) aged 20-50 years of both genders were included in the study. Patients with h/o previous histopathological diagnosis, already taking treatment and pregnant females were excluded. All the patients had chest x-ray and then HRCT. The x-ray and HRCT findings were recorded as presence or absence of the ILD. Results: Mean age was 40.21 ± 4.29 years. Out of 137 patients, 79 (57.66 percent) were males and 58 (42.34 percent) were females with male to female ratio of 1.36:1. Chest x-ray detected ILD in 80 (58.39 percent) patients, out of which, 72 (true positive) had ILD and 8 (false positive) had no ILD on HRCT. Overall sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of chest x-ray in diagnosing ILD was 80.0 percent, 82.98 percent, 90.0 percent, 68.42 percent and 81.02 percent respectively. Conclusion: This study concluded that chest x-ray is simple, non-invasive, economical and readily available alternative to HRCT with an acceptable diagnostic accuracy of 81 percent in the diagnosis of ILD. (author)

  19. High-resolution computed tomography findings from adult patients with Influenza A (H1N1) virus-associated pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Fluminense Federal University, Rio de Janeiro (Brazil); Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)], E-mail: edmarchiori@gmail.com; Zanetti, Glaucia [Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)], E-mail: glauciazanetti@gmail.com; Hochhegger, Bruno [Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)], E-mail: brunohochhegger@gmail.com; Rodrigues, Rosana Souza [Federal University of Rio de Janeiro, Rio de Janeiro (Brazil); D' OR Institute for Research and Education, Rio de Janeiro (Brazil)], E-mail: rosana.souzarodrigues@gmail.com; Fontes, Cristina Asvolinsque Pantaleao [Fluminense Federal University, Rio de Janeiro (Brazil)], E-mail: cristinasvolinsque@gmail.com; Nobre, Luiz Felipe [Santa Catarina Federal University, Florianopolis (Brazil)], E-mail: luizfelipenobresc@gmail.com; Dias Mancano, Alexandre [Anchieta Hospital, Taguatinga, DF (Brazil)], E-mail: alex.manzano1@gmail.com; Meirelles, Gustavo [Sao Paulo Federal University, Sao Paulo (Brazil)], E-mail: gmeirelles@gmail.com; Irion, Klaus Loureiro [Liverpool Heart and Chest Hospital NHS Trust, Liverpool (United Kingdom); Royal Liverpool and Broadgreen University Hospital NHS, Liverpool (United Kingdom)], E-mail: klaus.irion@btinternet.com

    2010-04-15

    Objective: The aim of this study was to assess the high-resolution computed tomography (HRCT) findings at presentation in patients diagnosed with Influenza A (H1N1) virus-associated pneumonia. Materials and methods: We reviewed the HRCT findings from 20 patients diagnosed with Influenza A (H1N1) and compared their HRCT scans with chest radiographs, obtained on the same day. The imaging studies were obtained 4-9 days after the onset of symptoms. The patients included 11 men and 9 women (ages 24-62 years; mean 42.7 years). All patients had a body temperature greater than 100.4 deg. F (>38 deg. C), tachypnea, and cough. Other common symptoms included diarrhea (60%) and sore throat (30%). The radiographs and HRCT scans were reviewed independently by two observers who reached a consensus decision. Results: The predominant HRCT findings consisted of bilateral ground-glass opacities (n = 12), bilateral areas of consolidation (n = 2), or a mixed bilateral pattern of ground-glass opacities and areas of consolidation (n = 6). The abnormalities were bilateral in all of the 20 patients, had a predominantly sub-pleural distribution in 13 patients, and had a random distribution in the remaining 7 patients. The predominant radiographic findings were consolidations. Normal radiographs were found in 4 out of the 20 patients. Conclusion: HRCT may reveal parenchymal abnormalities in patients with Influenza A (H1N1) infection who have normal findings on radiographs. The predominant HRCT findings were bilateral, peripheral, ground-glass opacities and/or bilateral areas of consolidation. The patients who presented consolidations had more severe clinical course.

  20. Super-resolution Phase Tomography

    KAUST Repository

    Depeursinge, Christian; Cotte, Yann; Toy, Fatih; Jourdain, Pascal; Boss, Daiel; Marquet, Pierre; Magistretti, Pierre J.

    2013-01-01

    Digital Holographic Microscopy (DHM) yields reconstructed complex wavefields. It allows synthesizing the aperture of a virtual microscope up to 2π, offering super-resolution phase images. Live images of micro-organisms and neurons with resolution less than 100 nm are presented.

  1. Super-resolution Phase Tomography

    KAUST Repository

    Depeursinge, Christian

    2013-04-21

    Digital Holographic Microscopy (DHM) yields reconstructed complex wavefields. It allows synthesizing the aperture of a virtual microscope up to 2π, offering super-resolution phase images. Live images of micro-organisms and neurons with resolution less than 100 nm are presented.

  2. Hypersensitivity pneumonitis (extrinsic allergic alveolitis): high-resolution computed tomography findings; Pneumonite por hipersensibilidade (alveolite alergica extrinseca): achados na tomografia computadorizada de alta resolucao

    Energy Technology Data Exchange (ETDEWEB)

    Almeida Junior, Jose Guiomar de; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Faculdade de Ciencias Medicas. Dept. de Radiologia]. E-mail: edmarchiori@zipmail.com.br; Escuissato, Dante L. [Parana Univ., Curitiba, PR (Brazil). Dept. de Radiologia; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Dept. de Radiologia; Gasparetto, Emerson L. [Parana Univ., Curitiba, PR (Brazil). Hospital de Clinicas; Nobre, Luiz Felipe [Santa Catarina Univ., Florianopolis, SC (Brazil); Irion, Klaus L. [Santa Casa de Misericordia de Porto Alegre, RS (Brazil). Pavilhao Pereira Filho. Servico de Radiologia

    2003-12-01

    Hypersensitivity pneumonitis, or extrinsic allergic alveolitis, is an immunologic disease of the lungs caused by inhaled chemicals or organics allergens. A lymphocytic inflammatory response in the peripheral airways and surrounding interstitial tissue occurs. In this study the high-resolution computed tomography findings of 13 patients with hypersensitivity pneumonitis were analyzed and discussed. The most frequent high-resolution computed tomography findings were: ground-glass opacities (92.3%), centrilobular nodules (38.4%) and air trapping (38.4%). Other findings included bronchiectasis (23.1%), consolidation (23.1%), crazy paving (7.7%), parenchymal bands (15.4%), linear opacities (7.7%), architectural distortion (7.7%), tracheal dilatation (7.7%), intralobular reticulate (7.7%), honeycombing (7.7%), emphysema (7.7%) and atelectasis (7.7%). In two of the 13 patients there was fibrosis (architectural distortion and honeycombing), which represents the chronic phase of the disease. (author)

  3. Paracoccidioidomycosis: high-resolution computed tomography - anatomo-pathological correlation; Paracoccidioidomicose: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson; Muniz, Maria Angelica Soares; Santos, Maria Lucia de Oliveira [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Radiologia; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Patologia; Capone, Domenico [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Pneumologia

    2000-12-01

    We reviewed the high-resolution computed tomography scans of 13 patients with paracoccidioidomycosis and correlated the findings with the anatomo-pathological findings of 5 patients. The most frequent findings observed were thickening of the interlobular septa, emphysema, ground glass areas, thickening of bronchial walls, tracheal dilatation, nodules, cavities and evidence of fibrosing disease such as architectural distortion, parenchymatous bands, spicular pleural thickening, intralobular reticulate and thickening with distortion off the axial interstitium. (author)

  4. Aspects of pulmonary histiocytosis X on high resolution computed tomography; Aspectos da histiocitose X pulmonar na tomografia computadorizada de alta resolucao (TCAR)

    Energy Technology Data Exchange (ETDEWEB)

    Costa, N.S.S.; Castro Lessa Angela, M.T. de; Angelo Junior, J.R.L.; Silva, F.M.D.; Kavakama, J.; Carvalho, C.R.R. de; Cerri, G.G. [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina. Hospital das Clinicas. Inst. do Coracao

    1995-01-01

    Pulmonary histiocytosis X is a disease that occurs in young adults and presents with nodules and cysts, mainly in upper lobes, with consequent pulmonary fibrosis. These pulmonary changes are virtually pathognomonic findings on high resolution computed tomography, that allows estimate the area of the lung involved and distinguish histiocytosis X from other disorders that also produces nodules and cysts. (author). 10 refs, 2 tabs, 6 figs.

  5. Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography

    Science.gov (United States)

    Habte, F.; Foudray, A. M. K.; Olcott, P. D.; Levin, C. S.

    2007-07-01

    We are studying two new detector technologies that directly measure the three-dimensional coordinates of 511 keV photon interactions for high-resolution positron emission tomography (PET) systems designed for small animal and breast imaging. These detectors are based on (1) lutetium oxyorthosilicate (LSO) scintillation crystal arrays coupled to position-sensitive avalanche photodiodes (PSAPD) and (2) cadmium zinc telluride (CZT). The detectors have excellent measured 511 keV photon energy resolutions (oriented 'edge-on' with respect to incoming 511 keV annihilation photons and arranged to form a compact FOV with detectors very close to, or in contact with, the subject tissues. In this paper, we used Monte Carlo simulation to study various factors that limit the photon sensitivity of a high-resolution PET system dedicated to small animal imaging. To optimize the photon sensitivity, we studied several possible system geometries for a fixed 8 cm transaxial and 8 cm axial FOV. We found that using rectangular-shaped detectors arranged into a cylindrical geometry does not yield the best photon sensitivity. This is due to the fact that forming rectangular-shaped detectors into a ring produces significant wedge-shaped inter-module gaps, through which Compton-scattered photons in the detector can escape. This effect limits the center point source photon sensitivity to 8% photon sensitivity for the LSO-PSAPD box configuration and >15% for CZT box geometry, using a 350-650 keV energy window setting. These simulation results compare well with analytical estimations. The trend is different for a clinical whole-body PET system that uses conventional LSO-PMT block detectors with larger crystal elements. Simulations predict roughly the same sensitivity for both box and cylindrical detector configurations. This results from the fact that a large system diameter (>80 cm) results in relatively small inter-module gaps in clinical whole-body PET. In addition, the relatively large block

  6. Computed tomography with selectable image resolution

    International Nuclear Information System (INIS)

    Dibianca, F.A.; Dallapiazza, D.G.

    1981-01-01

    A computed tomography system x-ray detector has a central group of half-width detector elements and groups of full-width elements on each side of the central group. To obtain x-ray attenuation data for whole body layers, the half-width elements are switched effectively into paralleled pairs so all elements act like full-width elements and an image of normal resolution is obtained. For narrower head layers, the elements in the central group are used as half-width elements so resolution which is twice as great as normal is obtained. The central group is also used in the half-width mode and the outside groups are used in the full-width mode to obtain a high resolution image of a body zone within a full body layer. In one embodiment data signals from the detector are switched by electronic multiplexing and in another embodiment a processor chooses the signals for the various kinds of images that are to be reconstructed. (author)

  7. Halo sign nodules in angio invasive pulmonary aspergillosis: correlation of high-resolution computed tomography findings with anatomopathology; Nodulos com sinal do halo na aspergilose pulmonar angioinvasiva: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Valiante, Paulo Marcos [Universidade Federal, Rio de Janeiro, RJ (Brazil). Dept. de Patologia; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Disciplina de Radiologia

    2002-08-01

    The aim of this study was to correlate the early findings observed on high-resolution computed tomography with anatomopathology results of patients with angio invasive aspergillosis. The authors studied two patients with leukemia. The nodules seen on high-resolution computed tomography corresponded to areas of hemorrhagic infarction, necrotic coagulation and fungal hyphae infiltration whereas ground glass halo corresponded to intra alveolar hemorrhage. Nodules with halo sign were closely correlated with anatomopathology findings. We concluded that the anatomopathology findings can clearly explain the image features of the lesions observed on high-resolution computed tomography. (author)

  8. Diagnosis of asbestosis by a time expanded wave form analysis, auscultation and high resolution computed tomography: a comparative study.

    Science.gov (United States)

    al Jarad, N; Strickland, B; Bothamley, G; Lock, S; Logan-Sinclair, R; Rudd, R M

    1993-01-01

    BACKGROUND--Crackles are a prominent clinical feature of asbestosis and may be an early sign of the condition. Auscultation, however, is subjective and interexaminer disagreement is a problem. Computerised lung sound analysis can visualise, store, and analyse lung sounds and disagreement on the presence of crackles is minimal. High resolution computed tomography (HRCT) is superior to chest radiography in detecting early signs of asbestosis. The aim of this study was to compare clinical auscultation, time expanded wave form analysis (TEW), chest radiography, and HRCT in detecting signs of asbestosis in asbestos workers. METHODS--Fifty three asbestos workers (51 men and two women) were investigated. Chest radiography and HRCT were assessed by two independent readers for detection of interstitial opacities. HRCT was performed in the supine position with additional sections at the bases in the prone position. Auscultation for persistent fine inspiratory crackles was performed by two independent examiners unacquainted with the diagnosis. TEW analysis was obtained from a 33 second recording of lung sounds over the lung bases. TEW and auscultation were performed in a control group of 13 subjects who had a normal chest radiograph. There were 10 current smokers and three previous smokers. In asbestos workers the extent of pulmonary opacities on the chest radiograph was scored according to the International Labour Office (ILO) scale. Patients were divided into two groups: 21 patients in whom the chest radiograph was > 1/0 (group 1) and 32 patients in whom the chest radiograph was scored auscultation in seven (22%) patients and by TEW in 14 (44%). HRCT detected definite interstitial opacities in 11 (34%) and gravity dependent subpleural lines in two (6%) patients. All but two patients with evidence of interstitial disease or gravity dependent subpleural lines on HRCT had crackles detected by TEW. In patients with an ILO score of > 1/0 auscultation and TEW revealed mid to late

  9. Bronchial asthma: correlation of high resolution computerized tomography findings with clinical data; Asma bronquica: correlacao de achados em tomografia computadorizada de alta resolucao com dados clinicos

    Energy Technology Data Exchange (ETDEWEB)

    Mogami, Roberto [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Servico de Radiologia; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Kirk, Kennedy; Capone, Domenico [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Servico de Pneumologia; Daltro, Pedro [Instituto Fernandes Figueira, Rio de Janeiro, RJ (Brazil). Servico de Radiologia

    1999-04-01

    In this work we did a sectional study of 31 asthmatic patients with several levels of disease severity, which were submitted to high resolution computed tomography of the thorax and spirometry, between the months of July, 1995 and August, 1997. The tomographic findings were correlated with the clinical classification of the patients and the most frequent tomographic findings were bronchial wall thickening, bronchial dilatation, air trapping, centrilobular opacities, cicatricial linear shadows, mucoid impaction, emphysema and atelectasis. In asthmatic patients of long duration we observed small airway disease and irreversible lesions as the predominant findings. In smoking patients there was no high frequency of emphysema. (author)

  10. Indications for application of a high resolution coil in MR tomography. Indikationen zur Applikation einer Hochaufloesungsspule in der MR-Tomographie

    Energy Technology Data Exchange (ETDEWEB)

    Maeurer, J. (Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany)); Requardt, H. (Siemens AG, Erlangen (Germany)); Mueller, F. (Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany)); Steinkamp, H.J. (Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany)); Hosten, N. (Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany)); Langer, R. (Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany)); Felix, R. (Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany))

    1994-04-01

    This is the first study with high spatial resolution Magnetic Resonance Imaging (MRI), performed with a high resolution coil in a clinical whole-body system. Measurements were recorded with a slice thickness of 2 mm. A 256x256 matrix and a 2.5 cm field of view were used resulting in a pixel size of 1.01 mm[sup 2]. MR images of the skin, hand, wrist, knee and ankle of 14 healthy volunteers, of three anatomic pathology tissue specimens and of three formalin-fixed specimens were obtained. Normal anatomy was identified and compared with the three gross anatomic pathology sections. The skin, hands, wrists and ankles of 30 patients were examined and a variety of pathological lesions were detected, including cutaneous neoplasms and ulceration, acute and chronic tendon lesions and pathologic features of the bone and wrist. Based on the excellent imaging of anatomic detail and superior contrast resolution, high resolution MRI proved an important complement for preoperative diagnosis. (orig.)

  11. Improvement in the detection of locoregional recurrence in head and neck malignancies: F-18 fluorodeoxyglucose-positron emission tomography/computed tomography compared to high-resolution contrast-enhanced computed tomography and endoscopic examination.

    Science.gov (United States)

    Rangaswamy, Balasubramanya; Fardanesh, M Reza; Genden, Eric M; Park, Eunice E; Fatterpekar, Girish; Patel, Zara; Kim, Jongho; Som, Peter M; Kostakoglu, Lale

    2013-11-01

    To compare the diagnostic efficacy of positron emission tomography (PET) with F-18 fluorodeoxyglucose (FDG-PET)/computed tomography (CT) to that of contrast-enhanced high-resolution CT (HRCT) and assess the value of a combinatorial approach in detection of recurrent squamous cell cancer of the head and neck (HNC) and to assess the efficacy of FDG-PET/CT with and without HRCT in comparison to standard-of-care follow-up--physical examination (PE) and endoscopy (E)--in determination of locally recurrent HNC. Retrospective study. A total of 103 patients with HNC underwent FDG-PET/CT and neck HRCT. There were two groups of patients: Group A had an FDG-PET study acquired with low-dose CT, and group B had an FDG-PET study acquired with HRCT. The PET data obtained with or without HRCT were compared on a lesion and patient basis with the results of the PE/E. On a lesion basis, both groups combined had higher sensitivity and negative predictive value (NPV) than the HRCT. Specificity and positive predictive value (PPV) for group B were higher than for group A. On a patient basis, both groups combined had a higher sensitivity and NPV than PE/E, respectively, although specificity of PE/E was higher than that of either group. PET data obtained with either protocol directly influenced treatment. HRCT increases the specificity and PPV of PET/CT when acquired simultaneously with PET. FDG-PET/CT acquired with either LDCT or HRCT has higher accuracy than HRCT alone and increases the sensitivity and NPV of PE/E. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  12. High-Resolution X-Ray Tomography: A 3D Exploration Into the Skeletal Architecture in Mouse Models Submitted to Microgravity Constraints

    Directory of Open Access Journals (Sweden)

    Alessandra Giuliani

    2018-03-01

    Full Text Available Bone remodeling process consists in a slow building phase and in faster resorption with the objective to maintain a functional skeleton locomotion to counteract the Earth gravity. Thus, during spaceflights, the skeleton does not act against gravity, with a rapid decrease of bone mass and density, favoring bone fracture. Several studies approached the problem by imaging the bone architecture and density of cosmonauts returned by the different spaceflights. However, the weaknesses of the previously reported studies was two-fold: on the one hand the research suffered the small statistical sample size of almost all human spaceflight studies, on the other the results were not fully reliable, mainly due to the fact that the observed bone structures were small compared with the spatial resolution of the available imaging devices. The recent advances in high-resolution X-ray tomography have stimulated the study of weight-bearing skeletal sites by novel approaches, mainly based on the use of the mouse and its various strains as an animal model, and sometimes taking advantage of the synchrotron radiation support to approach studies of 3D bone architecture and mineralization degree mapping at different hierarchical levels. Here we report the first, to our knowledge, systematic review of the recent advances in studying the skeletal bone architecture by high-resolution X-ray tomography after submission of mice models to microgravity constrains.

  13. A method for volume determination of the orbit and its contents by high resolution axial tomography and quantitative digital image analysis.

    Science.gov (United States)

    Cooper, W C

    1985-01-01

    The various congenital and acquired conditions which alter orbital volume are reviewed. Previous investigative work to determine orbital capacity is summarized. Since these studies were confined to postmortem evaluations, the need for a technique to measure orbital volume in the living state is presented. A method for volume determination of the orbit and its contents by high-resolution axial tomography and quantitative digital image analysis is reported. This procedure has proven to be accurate (the discrepancy between direct and computed measurements ranged from 0.2% to 4%) and reproducible (greater than 98%). The application of this method to representative clinical problems is presented and discussed. The establishment of a diagnostic system versatile enough to expand the usefulness of computerized axial tomography and polytomography should add a new dimension to ophthalmic investigation and treatment.

  14. High resolution 3D laboratory x-ray tomography data of femora from young, 1–14 day old C57BL/6 mice

    Directory of Open Access Journals (Sweden)

    Emely L. Bortel

    2015-09-01

    Full Text Available This data article contains high resolution (1.2 µm effective pixel size lab-based micro-computed tomography (µCT reconstructed volume data of the femoral mid-shafts from young C57BL/6 mice. This data formed the basis for the analyses of bone structural development in healthy mice, including closed and open porosity as reported in Bortel et al. [1]. The data reveals changes seen in bone material and porosity distribution observed when mouse bones transform from porous scaffolds into solid structures during normal organogenesis.

  15. Angioinvasive pulmonary aspergillosis after allogeneic bone marrow transplantation: clinical and high-resolution computed tomography findings in 12 cases

    OpenAIRE

    Gasparetto, Emerson L.; Souza, Carolina A.; Tazoniero, Priscilla; Davaus, Taisa; Escuissato, Dante L.; Marchiori, Edson

    2007-01-01

    The aim of this study was to present the clinical and high-resolution CT scan findings of angioinvasive pulmonary aspergillosis (APA) in 12 patients who underwent allogeneic bone marrow transplantation (BMT). The CT scans were reviewed by three chest radiologists who assessed the pattern and distribution of findings by consent. There were 7 (58%) female and 5 (42%) male patients, with aging between 5 and 50 years (average of 26 years). All patients were submitted to BMT for the treatment of h...

  16. Second Mesiobuccal Root Canal of Maxillary First Molars in a Brazilian Population in High-Resolution Cone-Beam Computed Tomography.

    Science.gov (United States)

    Gomes Alves, Claudia Rezende; Martins Marques, Márcia; Stella Moreira, Maria; Harumi Miyagi de Cara, Sueli Patricia; Silveira Bueno, Carlos Eduardo; Lascala, Cesar Ângelo

    2018-01-01

    The second canal of the mesiobuccal root (MB2) of the maxillary first molars (MFM) is difficult to detect in conventional radiographs and can be a major cause of failure in endodontic treatments. The aim of this study was to investigate the prevalence and anatomy of the MB2 by using high-resolution cone-beam computed tomography (CBCT). Three radiologists examined 414 high-resolution CBCTs. Of these, the CBCTs of 287 patients (mean age 49.43±16.76) who had at least one MFM were selected, making a total of 362 teeth. Prevalence and its relation with gender and age of the patients, side of the tooth, and Vertucci's classification were analyzed. Data were statistically analyzed ( P molars in this Brazilian population examined with high-resolution CBTCs is 68.23%, being more prevalent in young patients. Gender and the side examined are no factors for determining the presence of MB2. Although the both FOVs of the high-resolution CBTCs (FOV 8 and 5) detect the MB2 canal, smaller FOV (FOV 5) is more accurate in the analysis of the internal anatomy of such root canals, according to the Vertucci´s classification.

  17. Use of scanner characteristics in iterative image reconstruction for high-resolution positron emission tomography studies of small animals

    Energy Technology Data Exchange (ETDEWEB)

    Brix, G. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Doll, J. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Bellemann, M.E. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Trojan, H. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Haberkorn, U. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Schmidlin, P. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Ostertag, H. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany)

    1997-07-01

    The purpose of this work was to improve of the spatial resolution of a whole-body PET system for experimental studies of small animals by incorporation of scanner characteristics into the process of iterative image reconstruction. The image-forming characteristics of the PET camera were characterized by a spatially variant line-spread function (LSF), which was determined from 49 activated copper-64 line sources positioned over a field of view (FOV) of 21.0 cm. During the course of iterative image reconstruction, the forward projection of the estimated image was blurred with the LSF at each iteration step before the estimated projections were compared with the measured projections. Moreover, imaging studies of a rat and two nude mice were performed to evaluate the imaging properties of our approach in vivo. The spatial resolution of the scanner perpendicular to the direction of projection could be approximated by a one-dimensional Gaussian-shaped LSF with a full-width at half-maximum increasing from 6.5 mm at the centre to 6.7 mm at a radial distance of 10.5 cm. The incorporation of this blurring kernel into the iteration formula resulted in a significantly improved spatial resolution of about 3.9 mm over the examined FOV. As demonstrated by the phantom and the animal experiments, the high-resolution algorithm not only led to a better contrast resolution in the reconstructed emission scans but also improved the accuracy for quantitating activity concentrations in small tissue structures without leading to an amplification of image noise or image mottle. The presented data-handling strategy incorporates the image restoration step directly into the process of algebraic image reconstruction and obviates the need for ill-conditioned ``deconvolution`` procedures to be performed on the projections or on the reconstructed image. In our experience, the proposed algorithm is of special interest in experimental studies of small animals. (orig./AJ). With 9 figs.

  18. Use of scanner characteristics in iterative image reconstruction for high-resolution positron emission tomography studies of small animals

    International Nuclear Information System (INIS)

    Brix, G.; Doll, J.; Bellemann, M.E.; Trojan, H.; Haberkorn, U.; Schmidlin, P.; Ostertag, H.

    1997-01-01

    The purpose of this work was to improve of the spatial resolution of a whole-body PET system for experimental studies of small animals by incorporation of scanner characteristics into the process of iterative image reconstruction. The image-forming characteristics of the PET camera were characterized by a spatially variant line-spread function (LSF), which was determined from 49 activated copper-64 line sources positioned over a field of view (FOV) of 21.0 cm. During the course of iterative image reconstruction, the forward projection of the estimated image was blurred with the LSF at each iteration step before the estimated projections were compared with the measured projections. Moreover, imaging studies of a rat and two nude mice were performed to evaluate the imaging properties of our approach in vivo. The spatial resolution of the scanner perpendicular to the direction of projection could be approximated by a one-dimensional Gaussian-shaped LSF with a full-width at half-maximum increasing from 6.5 mm at the centre to 6.7 mm at a radial distance of 10.5 cm. The incorporation of this blurring kernel into the iteration formula resulted in a significantly improved spatial resolution of about 3.9 mm over the examined FOV. As demonstrated by the phantom and the animal experiments, the high-resolution algorithm not only led to a better contrast resolution in the reconstructed emission scans but also improved the accuracy for quantitating activity concentrations in small tissue structures without leading to an amplification of image noise or image mottle. The presented data-handling strategy incorporates the image restoration step directly into the process of algebraic image reconstruction and obviates the need for ill-conditioned ''deconvolution'' procedures to be performed on the projections or on the reconstructed image. In our experience, the proposed algorithm is of special interest in experimental studies of small animals. (orig./AJ). With 9 figs

  19. Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations.

    Science.gov (United States)

    Shokri, Abbas; Eskandarloo, Amir; Norouzi, Marouf; Poorolajal, Jalal; Majidi, Gelareh; Aliyaly, Alireza

    2018-03-01

    This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) scans obtained with 2 CBCT systems with high- and low-resolution modes for the detection of root perforations in endodontically treated mandibular molars. The root canals of 72 mandibular molars were cleaned and shaped. Perforations measuring 0.2, 0.3, and 0.4 mm in diameter were created at the furcation area of 48 roots, simulating strip perforations, or on the external surfaces of 48 roots, simulating root perforations. Forty-eight roots remained intact (control group). The roots were filled using gutta-percha (Gapadent, Tianjin, China) and AH26 sealer (Dentsply Maillefer, Ballaigues, Switzerland). The CBCT scans were obtained using the NewTom 3G (QR srl, Verona, Italy) and Cranex 3D (Soredex, Helsinki, Finland) CBCT systems in high- and low-resolution modes, and were evaluated by 2 observers. The chi-square test was used to assess the nominal variables. In strip perforations, the accuracies of low- and high-resolution modes were 75% and 83% for NewTom 3G and 67% and 69% for Cranex 3D. In root perforations, the accuracies of low- and high-resolution modes were 79% and 83% for NewTom 3G and was 56% and 73% for Cranex 3D. The accuracy of the 2 CBCT systems was different for the detection of strip and root perforations. The Cranex 3D had non-significantly higher accuracy than the NewTom 3G. In both scanners, the high-resolution mode yielded significantly higher accuracy than the low-resolution mode. The diagnostic accuracy of CBCT scans was not affected by the perforation diameter.

  20. High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography - initial experience

    International Nuclear Information System (INIS)

    Rist, Carsten; Nikolaou, Konstantin; Wintersperger, Bernd J.; Reiser, Maximilian F.; Becker, Christoph R.; Flohr, Thomas

    2006-01-01

    The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265±25HU and 254±16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367±36HU versus 402±28HU, P<0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68±0.08 mm versus 2.81±0.07 mm and 3.29±0.06 mm versus 3.18±0.07 mm (P<0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen. (orig.)

  1. Functional high-resolution computed tomography of pulmonary vascular and airway reactions. Experimental results. Funktionelle HR-CT der Lunge. Experimentelle Untersuchungen pulmonaler Gefaess- und Atemwegsreaktionen

    Energy Technology Data Exchange (ETDEWEB)

    Herold, C.J. (Universitaetsklinik fuer Radiodiagnostik, Vienna (Austria) Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Radiology); Brown, R.H. (Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Radiology Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Anesthesiology and Intensive Care Medicine Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Physiology); Wetzel, R.C.; Herold, S.M. (Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Anesthesiology and Intensive Care Medicine); Zeerhouni, E.A. (Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Radiology)

    1993-03-01

    We describe the use of high-resolution computed tomography (HRCT) for assessment of the function of pulmonary vessels and airways. With its excellent spatial resolution, HRCT is able to demonstrate pulmonary structures as small as 300 [mu]m and can be used to monitor changes following various stimuli. HRCT also provides information about structures smaller than 300 [mu]m through measurement of parenchymal background density. To date, sequential, spiral and ultrafast HRCT techniques have been used in a variety of challenges to gather information about the anatomical correlates of traditional physiological measurements, thus making anatomical-physiological correlation possible. HRCT of bronchial reactivity can demonstrate the location and time course of aerosol-induced broncho-constriction and may show changes not apparent on spirometry. HRCT of the pulmonary vascular system visualized adaptations of vessels during hypoxia and intravascular volume loading and elucidates cardiorespiratory interactions. Experimental studies provide a basis for potential clinical applications of this method. (orig.).

  2. Relationships (II) of International Classification of High-resolution Computed Tomography for Occupational and Environmental Respiratory Diseases with ventilatory functions indices for parenchymal abnormalities.

    Science.gov (United States)

    Tamura, Taro; Suganuma, Narufumi; Hering, Kurt G; Vehmas, Tapio; Itoh, Harumi; Akira, Masanori; Takashima, Yoshihiro; Hirano, Harukazu; Kusaka, Yukinori

    2015-01-01

    The International Classification of High-Resolution Computed Tomography (HRCT) for Occupational and Environmental Respiratory Diseases (ICOERD) is used to screen and diagnose respiratory illnesses. Using univariate and multivariate analysis, we investigated the relationship between subject characteristics and parenchymal abnormalities according to ICOERD, and the results of ventilatory function tests (VFT). Thirty-five patients with and 27 controls without mineral-dust exposure underwent VFT and HRCT. We recorded all subjects' occupational history for mineral dust exposure and smoking history. Experts independently assessed HRCT using the ICOERD parenchymal abnormalities (Items) grades for well-defined rounded opacities (RO), linear and/or irregular opacities (IR), and emphysema (EM). High-resolution computed tomography showed that 11 patients had RO; 15 patients, IR; and 19 patients, EM. According to the multiple regression model, age and height had significant associations with many indices ventilatory functions such as vital capacity, forced vital capacity, and forced expiratory volume in 1 s (FEV1). The EM summed grades on the upper, middle, and lower zones of the right and left lungs also had significant associations with FEV1 and the maximum mid-expiratory flow rate. The results suggest the ICOERD notation is adequate based on the good and significant multiple regression modeling of ventilatory function with the EM summed grades.

  3. High resolution aquifer characterization using crosshole GPR full-waveform tomography: Comparison with direct-push and tracer test data

    Science.gov (United States)

    Gueting, Nils; Vienken, Thomas; Klotzsche, Anja; van der Kruk, Jan; Vanderborght, Jan; Caers, Jef; Vereecken, Harry; Englert, Andreas

    2017-01-01

    Limited knowledge about the spatial distribution of aquifer properties typically constrains our ability to predict subsurface flow and transport. Here we investigate the value of using high resolution full-waveform inversion of cross-borehole ground penetrating radar (GPR) data for aquifer characterization. By stitching together GPR tomograms from multiple adjacent crosshole planes, we are able to image, with a decimeter scale resolution, the dielectric permittivity and electrical conductivity of an alluvial aquifer along cross sections of 50 m length and 10 m depth. A logistic regression model is employed to predict the spatial distribution of lithological facies on the basis of the GPR results. Vertical profiles of porosity and hydraulic conductivity from direct-push, flowmeter and grain size data suggest that the GPR predicted facies classification is meaningful with regard to porosity and hydraulic conductivity, even though the distributions of individual facies show some overlap and the absolute hydraulic conductivities from the different methods (direct-push, flowmeter, grain size) differ up to approximately one order of magnitude. Comparison of the GPR predicted facies architecture with tracer test data suggests that the plume splitting observed in a tracer experiment was caused by a hydraulically low-conductive sand layer with a thickness of only a few decimeters. Because this sand layer is identified by GPR full-waveform inversion but not by conventional GPR ray-based inversion we conclude that the improvement in spatial resolution due to full-waveform inversion is crucial to detect small-scale aquifer structures that are highly relevant for solute transport.

  4. High-resolution and high sensitivity mesoscopic fluorescence tomography based on de-scanning EMCCD: System design and thick tissue imaging applications

    Science.gov (United States)

    Ozturk, Mehmet Saadeddin

    Optical microscopy has been one of the essential tools for biological studies for decades, however, its application areas was limited to superficial investigation due to strong scattering in live tissues. Even though advanced techniques such as confocal or multiphoton methods have been recently developed to penetrate beyond a few hundreds of microns deep in tissues, they still cannot perform in the mesoscopic regime (millimeter scale) without using destructive sample preparation protocols such as clearing techniques. They provide rich cellular information; however, they cannot be readily employed to investigate the biological processes at larger scales. Herein, we will present our effort to establish a novel imaging approach that can quantify molecular expression in intact tissues, well beyond the current microscopy depth limits. Mesoscopic Fluorescence Molecular Tomography (MFMT) is an emerging imaging modality that offers unique potential for the non-invasive molecular assessment of thick in-vitro and in-vivo live tissues. This novel imaging modality is based on an optical inverse problem that allows for retrieval of the quantitative spatial distribution of fluorescent tagged bio-markers at millimeter depth. MFMT is well-suited for in-vivo subsurface tissue imaging and thick bio-printed specimens due to its high sensitivity and fast acquisition times, as well as relatively large fields of view. Herein, we will first demonstrate the potential of this technique using our first generation MFMT system applied to multiplexed reporter gene imaging (in-vitro) and determination of Photodynamic Therapy (PDT) agent bio-distribution in a mouse model (in-vivo). Second, we will present the design rationale, in silico benchmarking, and experimental validation of a second generation MFMT (2GMFMT) system. We will demonstrate the gain in resolution and sensitivity achieved due to the de-scanned dense detector configuration implemented. The potential of this novel platform will be

  5. Ultra-high resolution C-Arm CT arthrography of the wrist: Radiation dose and image quality compared to conventional multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Werncke, Thomas, E-mail: Werncke.Thomas@mh-hannover.de [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Sonnow, Lena; Meyer, Bernhard C. [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Lüpke, Matthias [University of Veterinary Medicine Hannover, Institute for General Radiology and Medical Physics, Bischofsholer Damm 15, 30173 Hannover (Germany); Hinrichs, Jan; Wacker, Frank K.; Falck, Christian von [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany)

    2017-04-15

    Objective: Objective of this phantom and cadaveric study was to compare the effective radiation dose (ED) and image quality (IQ) between C-arm computed tomography (CACT) using an ultra-high resolution 1 × 1 binning with a standard 16-slice CT (MDCT) arthrography of the wrist. Methods: ED was determined with thermoluminescence dosimetry using an anthropomorphic phantom and different patient positions. Imaging was conducted in 10 human cadaveric wrists after tri-compartmental injection of diluted iodinated contrast material and a wire phantom. IQ of MDCT was compared with CACT reconstructed with a soft (CACT1) and sharp (CACT2) kernel. High and low contrast resolution was determined. Three radiologists assessed IQ of wrist structures and occurrence of image artifacts using a 5-point Likert scale. Results: ED of MDCT was comparable to standard CACT (4.3 μSv/3.7 μSv). High contrast resolution was best for CACT2, decreased to CACT1 and MDCT. Low contrast resolution increased between CACT2 and MDCT (P < 0.001). IQ was best for CACT2 (1.3 ± 0.5), decreased to CACT1 (1.9 ± 0.6) and MDCT (3.5 ± 0.6). Non-compromising artifacts were only reported for CACT. Conclusions: The results of this phantom and cadaveric study indicate that ultra-high resolution C-Arm CT arthrography of the wrist bears the potential to outperform MDCT arthrography in terms of image quality and workflow at the cost of mildly increasing image artifacts while radiation dose to the patient is comparably low for both, MDCT and C-Arm CT.

  6. Identifying the most infectious lesions in pulmonary tuberculosis by high-resolution multi-detector computed tomography

    International Nuclear Information System (INIS)

    Yeh, Jun Jun; Chen, Solomon Chih-Cheng; Teng, Wen-Bao; Chou, Chun-Hsiung; Hsieh, Shih-Peng; Lee, Tsung-Lung; Wu, Ming-Ting

    2010-01-01

    This study aimed to determine whether characteristics detected by multi-detector computed tomography (MDCT) were predictive of highly infectious, smear-positive, active pulmonary tuberculosis (PTB). Among 124 patients with active PTB, 84 had positive (group 1) and 40 had negative (group 2) smear results for acid-fast bacilli. Multiplanar MDCT, axial conventional CT and chest X-ray images were analysed retrospectively for morphology, number, and segmental (lobe) distribution of lesions. By multivariate analysis, consolidation over any segment of the upper, middle, or lingual lobes, cavitations, and clusters of nodules were associated with group 1, while centrilobular nodules were predictive of group 2. Using five independent variables associated with risk in group 1, a prediction model was created to distinguish between group 1 and group 2. ROC curve analysis showed an area under the curve of 0.951 ± 0.021 for this prediction model. With the ideal cutoff point score of 1, the sensitivity, specificity, and positive predictive values were 84.5%, 97.5%, and 98.0%, respectively. A model to predict smear-positive active PTB on the basis of findings from MDCT may be a useful tool for clinical decisions about isolating patients pending sputum smear results. (orig.)

  7. Identifying the most infectious lesions in pulmonary tuberculosis by high-resolution multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, Jun Jun [Pingtung Christian Hospital, Pingtung (China); Mei-Ho Institute of Technology, Pingtung (China); China Medical University, Taichung (China); Chen, Solomon Chih-Cheng [Pingtung Christian Hospital, Pingtung (China); National Taiwan University, Institute of Occupational Medicine and Industrial Hygiene, College of Public Health, Taipei (China); Teng, Wen-Bao; Chou, Chun-Hsiung; Hsieh, Shih-Peng; Lee, Tsung-Lung [Pingtung Christian Hospital, Pingtung (China); Wu, Ming-Ting [National Yang Ming University, Faculty of Medicine, School of Medicine, Taipei (China); Kaohsiung Veterans General Hospital, Section of Thoracic and Circulation Imaging, Department of Radiology, Kaohsiung (China)

    2010-09-15

    This study aimed to determine whether characteristics detected by multi-detector computed tomography (MDCT) were predictive of highly infectious, smear-positive, active pulmonary tuberculosis (PTB). Among 124 patients with active PTB, 84 had positive (group 1) and 40 had negative (group 2) smear results for acid-fast bacilli. Multiplanar MDCT, axial conventional CT and chest X-ray images were analysed retrospectively for morphology, number, and segmental (lobe) distribution of lesions. By multivariate analysis, consolidation over any segment of the upper, middle, or lingual lobes, cavitations, and clusters of nodules were associated with group 1, while centrilobular nodules were predictive of group 2. Using five independent variables associated with risk in group 1, a prediction model was created to distinguish between group 1 and group 2. ROC curve analysis showed an area under the curve of 0.951 {+-} 0.021 for this prediction model. With the ideal cutoff point score of 1, the sensitivity, specificity, and positive predictive values were 84.5%, 97.5%, and 98.0%, respectively. A model to predict smear-positive active PTB on the basis of findings from MDCT may be a useful tool for clinical decisions about isolating patients pending sputum smear results. (orig.)

  8. High-resolution 3-D S-wave Tomography of upper crust structures in Yilan Plain from Ambient Seismic Noise

    Science.gov (United States)

    Chen, Kai-Xun; Chen, Po-Fei; Liang, Wen-Tzong; Chen, Li-Wei; Gung, YuanCheng

    2015-04-01

    The Yilan Plain (YP) in NE Taiwan locates on the western YP of the Okinawa Trough and displays high geothermal gradients with abundant hot springs, likely resulting from magmatism associated with the back-arc spreading as attested by the offshore volcanic island (Kueishantao). YP features NS distinctive characteristics that the South YP exhibits thin top sedimentary layer, high on-land seismicity and significant SE movements, relative those of the northern counterpart. A dense network (~2.5 km station interval) of 89 Texan instruments was deployed in Aug. 2014, covering most of the YP and its vicinity. The ray path coverage density of each 0.015 degree cells are greater than 150 km that could provide the robustness assessment of tomographic results. We analyze ambient noise signals to invert a high-resolution 3D S-wave model for shallow velocity structures in and around YP. The aim is to investigate the velocity anomalies corresponding to geothermal resources and the NS geological distinctions aforementioned. We apply the Welch's method to generate empirical Rayleigh wave Green's functions between two stations records of continuous vertical components. The group velocities of thus derived functions are then obtained by the multiple-filter analysis technique measured at the frequency range between 0.25 and 1 Hz. Finally, we implement a wavelet-based multi-scale parameterization technique to construct 3D model of S-wave velocity. Our first month results exhibit low velocity in the plain, corresponding existing sediments, those of whole YP show low velocity offshore YP and those of high-resolution south YP reveal stark velocity contrast across the Sanshin fault. Key words: ambient seismic noises, Welch's method, S-wave, Yilan Plain

  9. High Resolution Vp and Vp/Vs Local Earthquake Tomography of the Val d'Agri Region (Southern Apennines, Italy).

    Science.gov (United States)

    Improta, L.; Bagh, S.; De Gori, P.; Pastori, M.; Piccinini, D.; Valoroso, L.; Anselmi, M.; Buttinelli, M.; Chiarabba, C.

    2015-12-01

    The Val d'Agri (VA) Quaternary basin in the southern Apennines extensional belt hosts the largest oilfield in onshore Europe and normal-fault systems with high (up to M7) seismogenic potential. Frequent small-magnitude swarms related to both active crustal extension and anthropogenic activity have occurred in the region. Causal factors for induced seismicity are a water impoundment with severe seasonal oscillations and a high-rate wastewater injection well. We analyzed around 1200 earthquakes (MLENI petroleum company. We used local earthquake tomography to investigate static and transient features of the crustal velocity structure and to accurately locate earthquakes. Vp and Vp/Vs models are parameterized by a 3x3x2 km spacing and well resolved down to about 12 km depth. The complex Vp model illuminates broad antiformal structures corresponding to wide ramp-anticlines involving Mesozoic carbonates of the Apulia hydrocarbon reservoir, and NW-SE trending low Vp regions related to thrust-sheet-top clastic basins. The VA basin corresponds to shallow low-Vp region. Focal mechanisms show normal faulting kinematics with minor strike slip solutions in agreement with the local extensional regime. Earthquake locations and focal solutions depict shallow (< 5 km depth) E-dipping extensional structures beneath the artificial lake located in the southern sector of the basin, and along the western margin of the VA. A few swarms define relatively deep transfer structures accommodating the differential extension between main normal faults. The spatio-temporal distribution of around 220 events correlates with wastewater disposal activity, illuminating a NE-dipping fault between 2-5 km depth in the carbonate reservoir. The fault measures 5 km along dip and corresponds to a pre-existing thrust fault favorably oriented with respect to the local extensional field.

  10. Angioinvasive pulmonary aspergillosis after allogeneic bone marrow transplantation: clinical and high-resolution computed tomography findings in 12 cases

    Directory of Open Access Journals (Sweden)

    Emerson L. Gasparetto

    Full Text Available The aim of this study was to present the clinical and high-resolution CT scan findings of angioinvasive pulmonary aspergillosis (APA in 12 patients who underwent allogeneic bone marrow transplantation (BMT. The CT scans were reviewed by three chest radiologists who assessed the pattern and distribution of findings by consent. There were 7 (58% female and 5 (42% male patients, with aging between 5 and 50 years (average of 26 years. All patients were submitted to BMT for the treatment of hematological conditions. The diagnosis of APA was defined between 5 and 373 days after BMT, with average of 111 days. Three cases (25% were diagnosed in the neutropenic phase after the BMT, five (42% in the early phase and four patients in the late phase post-BMT. Regarding high-resolution CT (HRCT scan findings, nodules were found in 75% of the cases (9/12, most of the cases with more than 10 lesions (7/9 and of centrilobular localization (6/9. Consolidations were identified in seven patients (58%, being single in six, and commonly presenting ill defined borders (n=3 and subsegmental localization (n=5. Ground glass attenuation was found in six patients (50%. The halo sign was observed in nine cases (75%. Cavitations were seen in two air-space consolidations and one large nodule (2.5 cm. Patients submitted to BMT presenting respiratory symptoms and nodules or consolidations with halo sign at HRCT scan need to have the diagnosis of angioinvasive pulmonary aspergillosis included in all the post BMT phases.

  11. Angioinvasive pulmonary aspergillosis after allogeneic bone marrow transplantation: clinical and high-resolution computed tomography findings in 12 cases.

    Science.gov (United States)

    Gasparetto, Emerson L; Souza, Carolina A; Tazoniero, Priscilla; Davaus, Taisa; Escuissato, Dante L; Marchiori, Edson

    2007-02-01

    The aim of this study was to present the clinical and high-resolution CT scan findings of angioinvasive pulmonary aspergillosis (APA) in 12 patients who underwent allogeneic bone marrow transplantation (BMT). The CT scans were reviewed by three chest radiologists who assessed the pattern and distribution of findings by consent. There were 7 (58%) female and 5 (42%) male patients, with aging between 5 and 50 years (average of 26 years). All patients were submitted to BMT for the treatment of hematological conditions. The diagnosis of APA was defined between 5 and 373 days after BMT, with average of 111 days. Three cases (25%) were diagnosed in the neutropenic phase after the BMT, five (42%) in the early phase and four patients in the late phase post-BMT. Regarding high-resolution CT (HRCT) scan findings, nodules were found in 75% of the cases (9/12), most of the cases with more than 10 lesions (7/9) and of centrilobular localization (6/9). Consolidations were identified in seven patients (58%), being single in six, and commonly presenting ill defined borders (n=3) and subsegmental localization (n=5). Ground glass attenuation was found in six patients (50%). The halo sign was observed in nine cases (75%). Cavitations were seen in two air-space consolidations and one large nodule (2.5 cm). Patients submitted to BMT presenting respiratory symptoms and nodules or consolidations with halo sign at HRCT scan need to have the diagnosis of angioinvasive pulmonary aspergillosis included in all the post BMT phases.

  12. Esclerose sistêmica progressiva: aspectos na tomografia computadorizada de alta resolução Progressive systemic sclerosis: high-resolution computed tomography findings

    Directory of Open Access Journals (Sweden)

    Emerson L. Gasparetto

    2005-09-01

    Full Text Available OBJETIVO: Descrever os achados de tomografia computadorizada de alta resolução de pacientes com esclerose sistêmica pulmonar, independentemente dos sintomas respiratórios. MATERIAIS E MÉTODOS: Foram revisados 73 exames de tomografia computadorizada de alta resolução de 44 pacientes com diagnóstico de esclerodermia estabelecido através de critérios clínicos e laboratoriais. Os exames foram revisados por dois radiologistas, que estabeleceram os achados por consenso. RESULTADOS: Em 91,8% (n = 67 dos exames observaram-se alterações. Os principais achados foram lesões de padrão reticular (90,4%, opacidades em vidro-fosco (63%, bronquiectasias e bronquiolectasias de tração (56,2%, dilatação esofagiana (46,6%, faveolamento (28,8% e sinais de hipertensão pulmonar (15,6%. Na maioria dos casos as lesões eram bilaterais (89% e simétricas (58,5%. Quanto à localização, houve predomínio de lesões basais (91,2% e periféricas (92,2%. CONCLUSÃO: A esclerose sistêmica progressiva acarreta fibrose pulmonar na maioria dos pacientes, caracterizada principalmente por lesão reticular basal e periférica.OBJECTIVE: To describe the high-resolution computed tomography findings in the lung of patients with systemic sclerosis, independently of the respiratory symptoms. MATERIALS AND METHODS: Seventy-three high-resolution computed tomography scans of 44 patients with clinical diagnosis of systemic sclerosis were reviewed and defined by the consensus of two radiologists. RESULTS: Abnormalities were seen in 91.8% (n = 67 of the scans. The most frequent findings were reticular pattern (90.4%, ground-glass opacities (63%, traction bronchiectasis and bronchiolectasis (56.2%, esophageal dilatation (46.6%, honeycombing pattern (28.8% and signs of pulmonary hypertension (15.6%. In most cases the lesions were bilateral (89% and symmetrical (58.5%. The lesions were predominantly located in the basal (91.2% and peripheral (92.2% regions. CONCLUSION: In

  13. Effects of pure and hybrid iterative reconstruction algorithms on high-resolution computed tomography in the evaluation of interstitial lung disease.

    Science.gov (United States)

    Katsura, Masaki; Sato, Jiro; Akahane, Masaaki; Mise, Yoko; Sumida, Kaoru; Abe, Osamu

    2017-08-01

    To compare image quality characteristics of high-resolution computed tomography (HRCT) in the evaluation of interstitial lung disease using three different reconstruction methods: model-based iterative reconstruction (MBIR), adaptive statistical iterative reconstruction (ASIR), and filtered back projection (FBP). Eighty-nine consecutive patients with interstitial lung disease underwent standard-of-care chest CT with 64-row multi-detector CT. HRCT images were reconstructed in 0.625-mm contiguous axial slices using FBP, ASIR, and MBIR. Two radiologists independently assessed the images in a blinded manner for subjective image noise, streak artifacts, and visualization of normal and pathologic structures. Objective image noise was measured in the lung parenchyma. Spatial resolution was assessed by measuring the modulation transfer function (MTF). MBIR offered significantly lower objective image noise (22.24±4.53, PASIR (39.76±7.41) and FBP (51.91±9.71). MTF (spatial resolution) was increased using MBIR compared with ASIR and FBP. MBIR showed improvements in visualization of normal and pathologic structures over ASIR and FBP, while ASIR was rated quite similarly to FBP. MBIR significantly improved subjective image noise (PASIR and FBP. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography.

    Science.gov (United States)

    Carlson, Matthew L; Leng, Shuai; Diehn, Felix E; Witte, Robert J; Krecke, Karl N; Grimes, Josh; Koeller, Kelly K; Bruesewitz, Michael R; McCollough, Cynthia H; Lane, John I

    2017-08-01

    A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.

  15. High-resolution in vivo imaging of the cross-sectional deformations of contracting embryonic heart loops using optical coherence tomography

    DEFF Research Database (Denmark)

    Männer, J.; Thrane, Lars; Norozi, K.

    2008-01-01

    The embryonic heart tube consists of an outer myocardial tube, a middle layer of cardiac jelly, and an inner endocardial tube. It is said that tubular hearts pump the blood by peristaltoid contractions. The traditional concept of cardiac peristalsis sees the cyclic deformations of pulsating heart...... tubes as concentric narrowing and widening of tubes of circular cross-section. We have visualized the cross-sectional deformations of contracting embryonic hearts in chick embryos (HH-stages 9-17) using real-time high-resolution optical coherence tomography. Cardiac contractions are detected from HH...... of the endocardial tube is the consequence of an uneven distribution of the cardiac jelly. Our data show that the cyclic deformations of pulsating embryonic heart tubes run other than originally thought. There is evidence that heart tubes of elliptic cross-section might pump blood with a higher mechanical efficiency...

  16. Correlation between high-resolution computed tomography and galactomannan antigenemia in adult hematologic patients at risk for invasive aspergillosis

    International Nuclear Information System (INIS)

    Hidalgo, A.; Parody, R.; Martino, R.; Sanchez, F.; Franquet, T.; Gimenez, A.; Blancas, C.

    2009-01-01

    Objectives: To analyse the predominant radiological pattern of pulmonary lesions in adult hematologic patients at risk for invasive aspergillosis (IA) together with the results of serial serum Aspergillus galactomannan antigen testing (GM). Material and methods: In a prospective study for patients at high risk of aspergillus pulmonary infection, serum GM were performed 2-3 times per week during the periods of high risk for IA and high-resolution CT (HRCT) was performed in case of abnormal chest X-ray (CXR) and/or persistent fever after 5 days of antibiotic treatment. Changes on HRCT scan were classified as airway IA and angioinvasive IA. IA was classified as proven or probable in accordance with the definitions stated by the European Organization for Research and Treatment of Cancer/Mycosis Study Group (EORTC-MS). Positive GM testing was not considered as microbiological criterion. Results: 38 hematological patients were diagnosed of probable (n = 28) or proven (n = 10) IA. 55% patients had a neutrophil count less than 500 mm -3 (n = 21), and 37% patients ≥2 risk factors for IA. All probable IA were diagnosed by bronchoalveolar lavage (BAL). Proven IA was reached by positive histopathologic and culture results of samples obtained by autopsy (n = 4), percutaneous (n = 3) or transbronchial biopsy (n = 3). 18 patients had airway IA, and 60% had a GM level ≥1.5. 20 patients were diagnosed of angioinvasive IA from which 80% had a GM level ≥1.5. Conclusion: Serum GM levels may be lower in patients with airway IA than in those with an angioinvasive form. HRCT and serum GM are complementary tests in the diagnosis of IA.

  17. Development of a lab-scale, high-resolution, tube-generated X-ray computed-tomography system for three-dimensional (3D) materials characterization

    International Nuclear Information System (INIS)

    Mertens, J.C.E.; Williams, J.J.; Chawla, Nikhilesh

    2014-01-01

    The design and construction of a modular high resolution X-ray computed tomography (XCT) system is highlighted in this paper. The design approach is detailed for meeting a specified set of instrument performance goals tailored towards experimental versatility and high resolution imaging. The XCT tool is unique in the detector and X-ray source design configuration, enabling control in the balance between detection efficiency and spatial resolution. The system package is also unique: The sample manipulation approach implemented enables a wide gamut of in situ experimentation to analyze structure evolution under applied stimulus, by optimizing scan conditions through a high degree of controllability. The component selection and design process is detailed: Incorporated components are specified, custom designs are shared, and the approach for their integration into a fully functional XCT scanner is provided. Custom designs discussed include the dual-target X-ray source cradle which maintains position and trajectory of the beam between the two X-ray target configurations with respect to a scintillator mounting and positioning assembly and the imaging sensor, as well as a novel large-format X-ray detector with enhanced adaptability. The instrument is discussed from an operational point of view, including the details of data acquisition and processing implemented for 3D imaging via micro-CT. The performance of the instrument is demonstrated on a silica-glass particle/hydroxyl-terminated-polybutadiene (HTPB) matrix binder PBX simulant. Post-scan data processing, specifically segmentation of the sample's relevant microstructure from the 3D reconstruction, is provided to demonstrate the utility of the instrument. - Highlights: • Custom built X-ray tomography system for microstructural characterization • Detector design for maximizing polychromatic X-ray detection efficiency • X-ray design offered for maximizing X-ray flux with respect to imaging resolution

  18. Pneumocystis carinii pneumonia in acquired immunodeficiency syndrome - correlation of high-resolution computed tomography and anatomopathology; Pneumocistose na sindrome da imunodeficiencia adquirida: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson; Moreira, Luiza Beatriz [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: edmarchiori@zipmail.com.br; Capone, Domenico [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Patologia; Pereira, Cyntia Inez Guedes Soares

    2001-12-01

    We present the main findings observed on the high-resolution computed tomography examinations of 15 patients with acquired immunodeficiency syndrome and Pneumocystis carinii pneumonia. The high-resolution computed tomography and autopsy findings of 5 patients were also compared. The most frequently observed high-resolution computed tomography patterns were ground-glass attenuation, consolidation areas, crazy-paving pattern and cysts. Nodules and intralobular reticulation were less frequently observed. Ground-glass attenuation and consolidation areas corresponded to alveolar filling with inflammatory exudate. Thickening of the interlobular septa was due to cell infiltration and edema. One patient presented interlobular reticulation, and the pathology study revealed alveolar septa thickening due to cell infiltration and fibrosis. Nodules observed in one of the patients corresponded to a patchy intra alveolar accumulation of microorganisms and inflammatory cells forming a 'granulomatous' pattern. (author)

  19. Three-Dimensional Imaging and Numerical Reconstruction of Graphite/Epoxy Composite Microstructure Based on Ultra-High Resolution X-Ray Computed Tomography

    Science.gov (United States)

    Czabaj, M. W.; Riccio, M. L.; Whitacre, W. W.

    2014-01-01

    A combined experimental and computational study aimed at high-resolution 3D imaging, visualization, and numerical reconstruction of fiber-reinforced polymer microstructures at the fiber length scale is presented. To this end, a sample of graphite/epoxy composite was imaged at sub-micron resolution using a 3D X-ray computed tomography microscope. Next, a novel segmentation algorithm was developed, based on concepts adopted from computer vision and multi-target tracking, to detect and estimate, with high accuracy, the position of individual fibers in a volume of the imaged composite. In the current implementation, the segmentation algorithm was based on Global Nearest Neighbor data-association architecture, a Kalman filter estimator, and several novel algorithms for virtualfiber stitching, smoothing, and overlap removal. The segmentation algorithm was used on a sub-volume of the imaged composite, detecting 508 individual fibers. The segmentation data were qualitatively compared to the tomographic data, demonstrating high accuracy of the numerical reconstruction. Moreover, the data were used to quantify a) the relative distribution of individual-fiber cross sections within the imaged sub-volume, and b) the local fiber misorientation relative to the global fiber axis. Finally, the segmentation data were converted using commercially available finite element (FE) software to generate a detailed FE mesh of the composite volume. The methodology described herein demonstrates the feasibility of realizing an FE-based, virtual-testing framework for graphite/fiber composites at the constituent level.

  20. Tomography high Resolution CT findings of nontuberculous mycobacterial pulmonary disease: Comparison between the first treatment and the re treatment group

    Energy Technology Data Exchange (ETDEWEB)

    Gwak, Soon Hyuk; Cho, Bum Sang; Jeon, Min Hee; Kim, Eun Young; Kang, Min Ho; Yi, Kyung Sik; Lee, Seung Young; Kim, Sung Jin; Lee, Ki Man [Chungbuk National Univ., Cheongju, (Korea, Republic of)

    2012-06-15

    To analyze and compare the thin section CT findings of first and re treatment nontuberculous mycobacterial (NTM) pulmonary disease. Between January 2005 and April 2010, 121 patients with positive sputum culture for NTM were recruited. We included only 32 patients underwent high resolution chest CT and were confirmed by American Thoracic Society criteria NTM pulmonary infection (first treatment 15, re treatment 17 patients). CT images of 32 patients were reviewed retrospectively. We evaluated the frequency and laterality of the followings; nodule, increased density, bronchial change, parenchymal change. The significantly frequent CT findings of the re treatment NTM group were well defined nodules (retreatment 82.4%, first treatment 33.3%, p = 0.00), consolidations (retreatment 88.2%, first treatment 53.3%, p = 0.03), bronchial changes (bronchiectasis; retreatment 100%, first treatment 66.6%, p = 0.01, bronchial narrowing; retreatment 23.5%, first treatment 0%, p = 0.04 and mucoid impaction; retreatment-58.8%, first treatment-20.0%, p = 0.03) and atelectasis with bronchiectasis (retreatment-88.2%, first treatment 26.7%, p = 0.00). However, most of the evaluated thin section CT findings, such as centrilobular and ill defined nodules, lobular, segmental and subpleural consolidations, ground glass attenuation, bronchial wall thickening, cavities, pleural lesions, fibrotic band, emphysema and laterality of lesions, have not shown significant differences between first treatment and the re treatment group. Thin section CT findings of well defined nodules, consolidations, bronchial changes (bronchiectasis, bronchial narrowing and mucoid impaction) and atelectasis with bronchiectasis are highly suggestive of re treatment NTM pulmonary disease.

  1. Individual pore and interconnection size analysis of macroporous ceramic scaffolds using high-resolution X-ray tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jerban, Saeed, E-mail: saeed.jerban@usherbrooke.ca; Elkoun, Saïd, E-mail: Said.Elkoun@usherbrooke.ca

    2016-08-15

    The pore interconnection size of β-tricalcium phosphate scaffolds plays an essential role in the bone repair process. Although, the μCT technique is widely used in the biomaterial community, it is rarely used to measure the interconnection size because of the lack of algorithms. In addition, discrete nature of the μCT introduces large systematic errors due to the convex geometry of interconnections. We proposed, verified and validated a novel pore-level algorithm to accurately characterize the individual pores and interconnections. Specifically, pores and interconnections were isolated, labeled, and individually analyzed with high accuracy. The technique was verified thoroughly by visually inspecting and verifying over 3474 properties of randomly selected pores. This extensive verification process has passed a one-percent accuracy criterion. Scanning errors inherent in the discretization, which lead to both dummy and significantly overestimated interconnections, have been examined using computer-based simulations and additional high-resolution scanning. Then accurate correction charts were developed and used to reduce the scanning errors. Only after the corrections, both the μCT and SEM-based results converged, and the novel algorithm was validated. Material scientists with access to all geometrical properties of individual pores and interconnections, using the novel algorithm, will have a more-detailed and accurate description of the substitute architecture and a potentially deeper understanding of the link between the geometric and biological interaction. - Highlights: •An algorithm is developed to analyze individually all pores and interconnections. •After pore isolating, the discretization errors in interconnections were corrected. •Dummy interconnections and overestimated sizes were due to thin material walls. •The isolating algorithm was verified through visual inspection (99% accurate). •After correcting for the systematic errors, algorithm was

  2. In vivo visualization of photoreceptor layer and lipofuscin accumulation in Stargardt’s disease and fundus flavimaculatus by high resolution spectral-domain optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Giuseppe Querques

    2009-12-01

    Full Text Available Giuseppe Querques, Rosy Prato, Gabriel Coscas, Gisèle Soubrane, Eric H SouiedDepartment of Ophthalmology, Hopital Intercommunal de Creteil, University Paris XII, FranceIntroduction: To assess photoreceptor (PR layer morphology in patients with Stargardt’s disease (STGD and fundus flavimaculatus (FFM using high resolution spectral domain optical coherence tomography (HD-OCT; OCT 4000 Cirrus, Humphrey-Zeiss, San Leandro, CA.Methods: This was a prospective observational case series. Sixteen consecutive patients with STGD and FFM underwent a complete ophthalmologic examination. Optical coherence tomography examination was performed with HD-OCT, a high-speed (27,000 axial scans per second OCT system using spectral/Fourier domain detection, with an axial image resolution of 5 µm.Results: A total of 31 eyes were included in the study. Transverse loss of the PR layer in the foveal region was shown by HD-OCT. Twenty eyes with clinically evident central atrophy had a disruption of either the Verhoeff‘s membrane (VM or the layer corresponding to the interface of inner segment (IS and outer segment (OS of PR in the foveal region. Among these eyes, 12/20 eyes had a loss of the PR layer (loss of both VM and IS-OS interface in the foveal region. Eleven eyes (11/31 without clinically evident central atrophy had an intact interface of IS and OS of PR centrally. Moreover, we observed hyperreflective deposits: type 1 lesions located within the retinal pigment epithelium (RPE layer and at the level of the outer segments of PR, and type 2 lesions located at the level of the outer nuclear layer and clearly separated from the RPE layer. Type 1 lesions alone were associated with absence of loss of the PR layer in the foveal region in all eyes; type 2 lesions were always associated with presence of type 1 lesions, and often (8/12 eyes associated with loss of the PR layer within the foveal region. Mean best-corrected visual acuity (BCVA was significantly

  3. Interlobate esker architecture and related hydrogeological features derived from a combination of high-resolution reflection seismics and refraction tomography, Virttaankangas, southwest Finland

    Science.gov (United States)

    Maries, Georgiana; Ahokangas, Elina; Mäkinen, Joni; Pasanen, Antti; Malehmir, Alireza

    2017-05-01

    A novel high-resolution (2-4 m source and receiver spacing) reflection and refraction seismic survey was carried out for aquifer characterization and to confirm the existing depositional model of the interlobate esker of Virttaankangas, which is part of the Säkylänharju-Virttaankangas glaciofluvial esker-chain complex in southwest Finland. The interlobate esker complex hosting the managed aquifer recharge (MAR) plant is the source of the entire water supply for the city of Turku and its surrounding municipalities. An accurate delineation of the aquifer is therefore critical for long-term MAR planning and sustainable use of the esker resources. Moreover, an additional target was to resolve the poorly known stratigraphy of the 70-100-m-thick glacial deposits overlying a zone of fractured bedrock. Bedrock surface as well as fracture zones were confirmed through combined reflection seismic and refraction tomography results and further validated against existing borehole information. The high-resolution seismic data proved successful in accurately delineating the esker cores and revealing complex stratigraphy from fan lobes to kettle holes, providing valuable information for potential new pumping wells. This study illustrates the potential of geophysical methods for fast and cost-effective esker studies, in particular the digital-based landstreamer and its combination with geophone-based wireless recorders, where the cover sediments are reasonably thick.

  4. Flat-Panel Computed Tomography (DYNA-CT) in Neuroradiology. From High-Resolution Imaging of Implants to One-Stop-Shopping for Acute Stroke.

    Science.gov (United States)

    Doerfler, A; Gölitz, P; Engelhorn, T; Kloska, S; Struffert, T

    2015-10-01

    Originally aimed at improving standard radiography by providing higher absorption efficiency and a wider dynamic range, flat-panel detector technology has meanwhile got widely accepted in the neuroradiological community. Especially flat-panel detector computed tomography (FD-CT) using rotational C-arm mounted flat-panel detector technology is capable of volumetric imaging with a high spatial resolution. By providing CT-like images of the brain within the angio suite, FD-CT is able to rapidly visualize hemorrhage and may thus improve complication management without the need of patient transfer. As "Angiographic CT" FD-CT may be helpful during many diagnostic and neurointerventional procedures and for noninvasive monitoring and follow-up. In addition, spinal interventions and high-resolution imaging of the temporal bone might also benefit from FD-CT. Finally, using novel dynamic perfusion and angiographic protocols, FD-CT may provide functional information on brain perfusion and vasculature with the potential to replace standard imaging in selected acute stroke patients.

  5. Imaging of cellular spread on a three-dimensional scaffold by means of a novel cell-labeling technique for high-resolution computed tomography.

    Science.gov (United States)

    Thimm, Benjamin W; Hofmann, Sandra; Schneider, Philipp; Carretta, Roberto; Müller, Ralph

    2012-03-01

    Computed tomography (CT) represents a truly three-dimensional (3D) imaging technique that can provide high-resolution images on the cellular level. Thus, one approach to detect single cells is X-ray absorption-based CT, where cells are labeled with a dense, opaque material providing the required contrast for CT imaging. Within the present work, a novel cell-labeling method has been developed showing the feasibility of labeling fixed cells with iron oxide (FeO) particles for subsequent CT imaging and quantitative morphometry. A biotin-streptavidin detection system was exploited to bind FeO particles to its target endothelial cells. The binding of the particles was predominantly close to the cell centers on 2D surfaces as shown by light microscopy, scanning electron microscopy, and CT. When cells were cultured on porous, 3D polyurethane surfaces, significantly more FeO particles were detected compared with surfaces without cells and FeO particle labeling using CT. Here, we report on the implementation and evaluation of a novel cell detection method based on high-resolution CT. This system has potential in cell tracking for 3D in vitro imaging in the future.

  6. Prospects of linear reconstruction in atomic resolution electron holographic tomography

    International Nuclear Information System (INIS)

    Krehl, Jonas; Lubk, Axel

    2015-01-01

    Tomography commonly requires a linear relation between the measured signal and the underlying specimen property; for Electron Holographic Tomography this is given by the Phase Grating Approximation (PGA). While largely valid at medium resolution, discrepancies arise at high resolution imaging conditions. We set out to investigate the artefacts that are produced if the reconstruction still assumes the PGA even with an atomic resolution tilt series. To forego experimental difficulties the holographic tilt series was simulated. The reconstructed electric potential clearly shows peaks at the positions of the atoms. These peaks have characterisitic deformations, which can be traced back to the defocus a particular atom has in the holograms of the tilt series. Exchanging an atom for one of a different atomic number results in a significant change in the reconstructed potential that is well contained within the atom's peak. - Highlights: • We simulate a holographic tilt series of a nanocrystal with atomic resolution. • Using PGA-based Holographic Tomography we reconstruct the atomic structure. • The reconstruction shows characteristic artefacts, chiefly caused by defocus. • Changing one atom's Z produces a well localised in the reconstruction

  7. Prospects of linear reconstruction in atomic resolution electron holographic tomography

    Energy Technology Data Exchange (ETDEWEB)

    Krehl, Jonas, E-mail: Jonas.Krehl@triebenberg.de; Lubk, Axel

    2015-03-15

    Tomography commonly requires a linear relation between the measured signal and the underlying specimen property; for Electron Holographic Tomography this is given by the Phase Grating Approximation (PGA). While largely valid at medium resolution, discrepancies arise at high resolution imaging conditions. We set out to investigate the artefacts that are produced if the reconstruction still assumes the PGA even with an atomic resolution tilt series. To forego experimental difficulties the holographic tilt series was simulated. The reconstructed electric potential clearly shows peaks at the positions of the atoms. These peaks have characterisitic deformations, which can be traced back to the defocus a particular atom has in the holograms of the tilt series. Exchanging an atom for one of a different atomic number results in a significant change in the reconstructed potential that is well contained within the atom's peak. - Highlights: • We simulate a holographic tilt series of a nanocrystal with atomic resolution. • Using PGA-based Holographic Tomography we reconstruct the atomic structure. • The reconstruction shows characteristic artefacts, chiefly caused by defocus. • Changing one atom's Z produces a well localised in the reconstruction.

  8. Submicron Resolution Spectral-Domain Optical Coherence Tomography

    KAUST Repository

    Alarousu, Erkki; Jabbour, Ghassan

    2013-01-01

    Apparatuses and systems for submicron resolution spectral-domain optical coherence tomography (OCT) are disclosed. The system may use white light sources having wavelengths within 400-1000 nanometers, and achieve resolution below 1 .mu

  9. ANL high resolution injector

    International Nuclear Information System (INIS)

    Minehara, E.; Kutschera, W.; Hartog, P.D.; Billquist, P.

    1985-01-01

    The ANL (Argonne National Laboratory) high-resolution injector has been installed to obtain higher mass resolution and higher preacceleration, and to utilize effectively the full mass range of ATLAS (Argonne Tandem Linac Accelerator System). Preliminary results of the first beam test are reported briefly. The design and performance, in particular a high-mass-resolution magnet with aberration compensation, are discussed. 7 refs., 5 figs., 2 tabs

  10. Preclinical evaluation and intraoperative human retinal imaging with a high-resolution microscope-integrated spectral domain optical coherence tomography device.

    Science.gov (United States)

    Hahn, Paul; Migacz, Justin; O'Donnell, Rachelle; Day, Shelley; Lee, Annie; Lin, Phoebe; Vann, Robin; Kuo, Anthony; Fekrat, Sharon; Mruthyunjaya, Prithvi; Postel, Eric A; Izatt, Joseph A; Toth, Cynthia A

    2013-01-01

    The authors have recently developed a high-resolution microscope-integrated spectral domain optical coherence tomography (MIOCT) device designed to enable OCT acquisition simultaneous with surgical maneuvers. The purpose of this report is to describe translation of this device from preclinical testing into human intraoperative imaging. Before human imaging, surgical conditions were fully simulated for extensive preclinical MIOCT evaluation in a custom model eye system. Microscope-integrated spectral domain OCT images were then acquired in normal human volunteers and during vitreoretinal surgery in patients who consented to participate in a prospective institutional review board-approved study. Microscope-integrated spectral domain OCT images were obtained before and at pauses in surgical maneuvers and were compared based on predetermined diagnostic criteria to images obtained with a high-resolution spectral domain research handheld OCT system (HHOCT; Bioptigen, Inc) at the same time point. Cohorts of five consecutive patients were imaged. Successful end points were predefined, including ≥80% correlation in identification of pathology between MIOCT and HHOCT in ≥80% of the patients. Microscope-integrated spectral domain OCT was favorably evaluated by study surgeons and scrub nurses, all of whom responded that they would consider participating in human intraoperative imaging trials. The preclinical evaluation identified significant improvements that were made before MIOCT use during human surgery. The MIOCT transition into clinical human research was smooth. Microscope-integrated spectral domain OCT imaging in normal human volunteers demonstrated high resolution comparable to tabletop scanners. In the operating room, after an initial learning curve, surgeons successfully acquired human macular MIOCT images before and after surgical maneuvers. Microscope-integrated spectral domain OCT imaging confirmed preoperative diagnoses, such as full-thickness macular hole

  11. High-resolution electrical resistivity tomography applied to patterned ground, Wedel Jarlsberg Land, south-west Spitsbergen

    Directory of Open Access Journals (Sweden)

    Marek Kasprzak

    2015-06-01

    Full Text Available This article presents results of two-dimensional electrical resistivity tomography (ERT applied to three types of patterned ground in Wedel-Jarlsberg Land (Svalbard, carried out in late July 2012. The structures investigated include sorted circles, non-sorted polygons and a net with sorted coarser material. ERT was used to recognize the internal ground structure, the shape of permafrost table below the active layer and the geometric relationships between permafrost, ground layering and surface patterns. Results of inversion modelling indicate that the permafrost table occurs at a depth of 0.5–1 m in a mountain valley and 1–2.5 m on raised marine terraces. The permafrost table was nearly planar beneath non-sorted deposits and wavy beneath sorted materials. The mutual relationships between the permafrost table and the shape of a stone circle are different from those typically presented in literature. Ground structure beneath the net with sorted coarser materials is complex as implied in convective models. In non-sorted polygons, the imaging failed to reveal vertical structures between them.

  12. High-resolution computed tomography to differentiate chronic diffuse interstitial lung diseases with predominant ground-glass pattern using logical analysis of data

    International Nuclear Information System (INIS)

    Martin, Sophie Grivaud; Brauner, Michel W.; Rety, Frederique; Kronek, Louis-Philippe; Brauner, Nadia; Valeyre, Dominique; Nunes, Hilario; Brillet, Pierre-Yves

    2010-01-01

    We evaluated the performance of high-resolution computed tomography (HRCT) to differentiate chronic diffuse interstitial lung diseases (CDILD) with predominant ground-glass pattern by using logical analysis of data (LAD). A total of 162 patients were classified into seven categories: sarcoidosis (n = 38), connective tissue disease (n = 32), hypersensitivity pneumonitis (n = 18), drug-induced lung disease (n = 15), alveolar proteinosis (n = 12), idiopathic non-specific interstitial pneumonia (n = 10) and miscellaneous (n = 37). First, 40 CT attributes were investigated by the LAD to build up patterns characterising a category. From the association of patterns, LAD determined models specific to each CDILD. Second, data were recomputed by adding eight clinical attributes to the analysis. The 20 x 5 cross-folding method was used for validation. Models could be individualised for sarcoidosis, hypersensitivity pneumonitis, connective tissue disease and alveolar proteinosis. An additional model was individualised for drug-induced lung disease by adding clinical data. No model was demonstrated for idiopathic non-specific interstitial pneumonia and the miscellaneous category. The results showed that HRCT had a good sensitivity (≥64%) and specificity (≥78%) and a high negative predictive value (≥93%) for diseases with a model. Higher sensitivity (≥78%) and specificity (≥89%) were achieved by adding clinical data. The diagnostic performance of HRCT is high and can be increased by adding clinical data. (orig.)

  13. Serial High-Resolution Computed Tomography Imaging in Patients with Wegener Granulomatosis: Differentiation Between Active Inflammatory and Chronic Fibrotic Lesions

    International Nuclear Information System (INIS)

    Lohrmann, C.; Uhl, M.; Schaefer, O.; Ghanem, N.; Kotter, E.; Langer, M.

    2005-01-01

    PURPOSE: To evaluate pulmonary pathologies in Wegener granulomatosis with sequential computed tomography (CT) in order to differentiate active inflammatory lesions from chronic fibrotic lesions. MATERIAL AND METHODS: Serial CT findings in 38 patients with Wegener granulomatosis were retrospectively analyzed (mean follow-up period, 21 months). The presence, extension, and distribution of the following findings were evaluated with CT: parenchymal nodules, masses, ground-glass attenuation, airspace consolidation, bronchial wall-thickening, bronchiectasis, linear areas of attenuation, pleural irregularities, pleural effusions, hilar and mediastinal lymphadenopathy. RESULTS: Observed in 92% of patients, nodules were the most common CT pathology. Areas of ground-glass attenuation, consolidation, masses of linear attenuation, and tracheal/bronchial wall-thickening were detected in 24%, 26%, 32%, 39%, and 68% of patients. At follow-up, the clearance of lesions was most consistent for areas of ground-glass attenuation (89%), masses (87%), and cavitated nodules (85%). In the follow-up scan, 58% of all nodules, 47% of pulmonary consolidations, and 66% of bronchial wall-thickening were completely resolved. Areas of bronchiectasis and septal/non-septal lines remained stable in 70% and 71% of patients. CONCLUSION: The majority of the lesions decreased or resolved completely with or without areas of linear attenuation. Ground-glass attenuation, cavitated nodules and masses appear to represent active inflammatory lesions. In most probability, areas of bronchiectasis and septal/non-septal lines more often represent chronic fibrotic changes rather than active inflammatory changes. In combination with clinical evaluation and bronchoscopy, CT assists in the assessment of disease activity

  14. Serial High-Resolution Computed Tomography Imaging in Patients with Wegener Granulomatosis: Differentiation Between Active Inflammatory and Chronic Fibrotic Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lohrmann, C.; Uhl, M.; Schaefer, O.; Ghanem, N.; Kotter, E.; Langer, M. [Univ. Hospital of Freiburg (Germany). Dept. of Radiology

    2005-08-01

    PURPOSE: To evaluate pulmonary pathologies in Wegener granulomatosis with sequential computed tomography (CT) in order to differentiate active inflammatory lesions from chronic fibrotic lesions. MATERIAL AND METHODS: Serial CT findings in 38 patients with Wegener granulomatosis were retrospectively analyzed (mean follow-up period, 21 months). The presence, extension, and distribution of the following findings were evaluated with CT: parenchymal nodules, masses, ground-glass attenuation, airspace consolidation, bronchial wall-thickening, bronchiectasis, linear areas of attenuation, pleural irregularities, pleural effusions, hilar and mediastinal lymphadenopathy. RESULTS: Observed in 92% of patients, nodules were the most common CT pathology. Areas of ground-glass attenuation, consolidation, masses of linear attenuation, and tracheal/bronchial wall-thickening were detected in 24%, 26%, 32%, 39%, and 68% of patients. At follow-up, the clearance of lesions was most consistent for areas of ground-glass attenuation (89%), masses (87%), and cavitated nodules (85%). In the follow-up scan, 58% of all nodules, 47% of pulmonary consolidations, and 66% of bronchial wall-thickening were completely resolved. Areas of bronchiectasis and septal/non-septal lines remained stable in 70% and 71% of patients. CONCLUSION: The majority of the lesions decreased or resolved completely with or without areas of linear attenuation. Ground-glass attenuation, cavitated nodules and masses appear to represent active inflammatory lesions. In most probability, areas of bronchiectasis and septal/non-septal lines more often represent chronic fibrotic changes rather than active inflammatory changes. In combination with clinical evaluation and bronchoscopy, CT assists in the assessment of disease activity.

  15. Aortic and Cardiac Structure and Function Using High-Resolution Echocardiography and Optical Coherence Tomography in a Mouse Model of Marfan Syndrome.

    Directory of Open Access Journals (Sweden)

    Ling Lee

    Full Text Available Marfan syndrome (MFS is an autosomal-dominant disorder of connective tissue caused by mutations in the fibrillin-1 (FBN1 gene. Mortality is often due to aortic dissection and rupture. We investigated the structural and functional properties of the heart and aorta in a [Fbn1C1039G/+] MFS mouse using high-resolution ultrasound (echo and optical coherence tomography (OCT. Echo was performed on 6- and 12-month old wild type (WT and MFS mice (n = 8. In vivo pulse wave velocity (PWV, aortic root diameter, ejection fraction, stroke volume, left ventricular (LV wall thickness, LV mass and mitral valve early and atrial velocities (E/A ratio were measured by high resolution echocardiography. OCT was performed on 12-month old WT and MFS fixed mouse hearts to measure ventricular volume and mass. The PWV was significantly increased in 6-mo MFS vs. WT (366.6 ± 19.9 vs. 205.2 ± 18.1 cm/s; p = 0.003 and 12-mo MFS vs. WT (459.5 ± 42.3 vs. 205.3 ± 30.3 cm/s; p< 0.0001. PWV increased with age in MFS mice only. We also found a significantly enlarged aortic root and decreased E/A ratio in MFS mice compared with WT for both age groups. The [Fbn1C1039G/+] mouse model of MFS replicates many of the anomalies of Marfan patients including significant aortic dilation, central aortic stiffness, LV systolic and diastolic dysfunction. This is the first demonstration of the direct measurement in vivo of pulse wave velocity non-invasively in the aortic arch of MFS mice, a robust measure of aortic stiffness and a critical clinical parameter for the assessment of pathology in the Marfan syndrome.

  16. Analyses of the eustachian tube and its surrounding tissues with cross sectional images by high-resolution computed tomography (HR-CT)

    International Nuclear Information System (INIS)

    Yoshida, Haruo; Kobayashi, Toshimitsu; Takasaki, Kenji; Kanda, Yukihiko; Nakao, Yoshiaki; Morikawa, Minoru; Ishimaru, Hideki; Hayashi, Kuniaki

    2000-01-01

    We attempted to image the eustachian tube (ET) and its surrounding tissues by high-resolution computed tomography (HR-CT). Twenty-two normal subjects (44 ears) without middle ear problems were studied, and a patient with severe patulous ET was also studied as an abnormal case. In our device of multiplanar reconstruction technique, we were able to obtain the clear reconstructed images of the ET lumen as well as of its surrounding tissues (bone, ET cartilage, tensor veli palatini muscle, levator veli palatini muscle, Ostmann's fat tissue, tensor tympani muscle, internal carotid artery) at any desired portion, either parallel or perpendicular to the long axis of the ET. However, the exact borders between the ET cartilage and the muscles, Ostmann's fat tissue and the tubal gland were not clearly identified. In the severe case of patulous ET, the ET lumen was widely opened at each cross-sectional image from the pharyngeal orifice to the tympanic orifice, in contrast with its being closed at the cartilaginous portion in the normal cases. In addition, the fat tissue and glands around the ET lumen were not clearly identified in this case. We suggest that this method will lead to better understanding of the ET-related diseases such as patulous ET. (author)

  17. Analyses of the eustachian tube and its surrounding tissues with cross sectional images by high-resolution computed tomography (HR-CT)

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Haruo; Kobayashi, Toshimitsu; Takasaki, Kenji; Kanda, Yukihiko; Nakao, Yoshiaki; Morikawa, Minoru; Ishimaru, Hideki; Hayashi, Kuniaki [Nagasaki Univ. (Japan). School of Medicine

    2000-07-01

    We attempted to image the eustachian tube (ET) and its surrounding tissues by high-resolution computed tomography (HR-CT). Twenty-two normal subjects (44 ears) without middle ear problems were studied, and a patient with severe patulous ET was also studied as an abnormal case. In our device of multiplanar reconstruction technique, we were able to obtain the clear reconstructed images of the ET lumen as well as of its surrounding tissues (bone, ET cartilage, tensor veli palatini muscle, levator veli palatini muscle, Ostmann's fat tissue, tensor tympani muscle, internal carotid artery) at any desired portion, either parallel or perpendicular to the long axis of the ET. However, the exact borders between the ET cartilage and the muscles, Ostmann's fat tissue and the tubal gland were not clearly identified. In the severe case of patulous ET, the ET lumen was widely opened at each cross-sectional image from the pharyngeal orifice to the tympanic orifice, in contrast with its being closed at the cartilaginous portion in the normal cases. In addition, the fat tissue and glands around the ET lumen were not clearly identified in this case. We suggest that this method will lead to better understanding of the ET-related diseases such as patulous ET. (author)

  18. Bronchoalveolar lavage cellular analyses in conjunction with high-resolution computed tomography imaging as a diagnostic intervention for patients with suspected interstitial lung disease

    Directory of Open Access Journals (Sweden)

    Ammaiyappan Chockalingam

    2016-01-01

    Full Text Available Background: Bronchoalveolar lavage (BAL has gained acceptance for diagnosis of Interstitial lung disease (ILD. The advent of high-resolution computed tomography (HRCT has reduced the clinical utility of BAL. This work has utilized the recommendations of the American Thoracic Society (ATS to optimize BAL and the findings have been associated with clinical examination and HRCT to precisely narrow down the cause of ILD. Materials and Methods: BAL was performed on ILD suspects at the target site chosen based on HRCT. The procedure, transport, processing, and analysis of BAL fluid were performed as per the ATS guidelines. The clinical data, HRCT findings and BAL report were used to narrow down the diagnosis of ILD. The statistical analysis was performed to assess the significance. Results: The BAL procedure was optimized as per the recommendations of the ATS. In a cohort of 50 patients, Idiopathic pulmonary fibrosis, (8 hypersensitivity pneumonitis, (17 connective tissue disorder, (9 sarcoidosis, (3 pneumoconiosis, (5 acute respiratory distress syndrome, (2 eosinophilic lung disease (2 and lymphangitic carcinomatosa, (2 aspiration bronchiolitis (1 and pulmonary histiocytosis (1 were diagnosed. Statistically significant variation in differential counts was found in different ILDs. The different ILDs were classified based on the criteria described by the ATS. Clinical Significance: BAL along with clinical and HRCT findings improved the diagnostic accuracy by incorporating, the acute or chronic nature of the disease and the cause for acute exacerbation, which helped in the better management of ILDs.

  19. Utility of the inspiratory phase in high-resolution computed tomography evaluations of pediatric patients with bronchiolitis obliterans after allogeneic bone marrow transplant: reducing patient radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Togni Filho, Paulo Henrique; Casagrande, Joao Luiz Marin; Lederman, Henrique Manoel, E-mail: paulotognifilho@gmail.com [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Dept. of Diagnostico por Imagem; Universidade de Sao Paulo (InRad/HC/FMUSP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Instituto de Radiologia

    2017-03-15

    Objective: To evaluate the utility of the inspiratory phase in high-resolution computed tomography (HRCT) of the chest for the diagnosis of post-bone marrow transplantation bronchiolitis obliterans. Materials and Methods: This was a retrospective, observational, cross-sectional study. We selected patients of either gender who underwent bone marrow transplantation and chest HRCT between March 1, 2002 and December 12, 2014. Ages ranged from 3 months to 20.7 years. We included all examinations in which the HRCT was performed appropriately. The examinations were read by two radiologists, one with extensive experience in pediatric radiology and another in the third year of residency, who determined the presence or absence of the following imaging features: air trapping, bronchiectasis, alveolar opacities, nodules, and atelectasis. Results: A total of 222 examinations were evaluated (mean, 5.4 ± 4.5 examinations per patient). The expiratory phase findings were comparable to those obtained in the inspiratory phase, except in one patient, in whom a small uncharacteristic nodule was identified only in the inspiratory phase. Air trapping was identified in a larger number of scans in the expiratory phase than in the inspiratory phase, as was atelectasis, although the difference was statistically significant only for air trapping. Conclusion: In children being evaluated for post-bone marrow transplantation bronchiolitis obliterans, the inspiratory phase can be excluded from the chest HRCT protocol, thus reducing by half the radiation exposure in this population. (author)

  20. Interstitial pulmonary alterations in visceral leishmaniasis: evaluation with high-resolution computed tomography; Alteracoes pulmonares intersticiais na leishmaniose visceral: avaliacao pela tomografia computadorizada de alta resolucao

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Norma Selma Santos; Cerri, Giovanni Guido [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina. Dept. de Radiologia

    1999-08-01

    Visceral leishmaniasis, also called kala-azar, is a disease caused by a protozoan, the Leishmania donovani chagasi, that comprises reticuloendothelial system with involvement of the liver, spleen and bone marrow. It is endemic in some areas of northeastern Brazil and other countries of Latin America and Africa. The pathogenesis is related to the immunologic system of patients that present with the inability to activate the phagocytosis of the macrophages. As occurs in the liver and kidneys, the lungs are also involved with interstitial abnormalities caused by Leishmania that are not dependent upon the presence of the parasite. The histopathologic changes described are the involvement of inter alveolar septal in three different phases, irregularly and diffusely throughout the whole pulmonary parenchyma. This work analyzed high-resolution computed tomography (HRCT) of the thorax in 17 patients with visceral leishmaniasis in order to detect and characterize the abnormalities described in the anatomo pathologic findings reported in the literature. The HRCT is being used to evaluate chronic interstitial lung disease in a good correlation with histologic findings. The most common findings detected by HRCT were the reticular opacities that include peribronchovascular interstitial thickening and interlobular septal thickening an ground-glass opacity. The HRCT suggests that similar changes to that found in alveolar structures may occur in the secondary pulmonary lobule and that the involvement in the parenchymal interstitium represents the findings reported by pathological studies in visceral leishmaniasis. (author)

  1. The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas

    International Nuclear Information System (INIS)

    Krestan, C.; Czerny, C.; Gstoettner, W.; Franz, P.

    2003-01-01

    The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions caused by recurrent cholesteatoma, bony defects of the facial nerve and of the labyrinth, and a defect of the tegmen tympani with a soft tissue mass in the middle ear. Postoperative MRI delineated neuritis of the facial nerve, labyrinthitis, and a meningo-encephalocele protruding into the middle ear. HRCT and MRI are excellent imaging tools to depict either bony or soft tissue complications or both if caused by acquired cholesteatomas. According to our findings and to the literature HRCT and MRI are complementary imaging methods to depict pre- or postoperative complications of acquired cholesteatomas if these are suspected by clinical examination. (orig.) [de

  2. Risk of acute exacerbation of interstitial pneumonia after pulmonary resection for lung cancer in patients with idiopathic pulmonary fibrosis based on preoperative high-resolution computed tomography

    International Nuclear Information System (INIS)

    Suzuki, Hidemi; Sekine, Yasuo; Yoshida, Shigetoshi

    2011-01-01

    In patients with lung cancer accompanied by idiopathic pulmonary fibrosis (IPF), acute exacerbation of the IPF often occurs after pulmonary resection; however, few studies have been done to identify its preexisting risk factors. We analyzed the high-resolution computed tomography (HRCT) findings of IPF to identify the radiological characteristics of IPF susceptible to acute exacerbation after lung cancer surgery. We reviewed retrospectively 28 lung cancer patients with IPF who underwent pulmonary resection. Clinical data, respiratory function, HRCT findings, and historical features were compared between the acute exacerbation (n=9) and nonexacerbation (n=19) groups. The classification of radiological findings of IPF on HRCT was done using a scoring system of seven factors related to the interstitial shadow, including fibrosis, ground-glass opacity, and low-attenuation area. There were no significant differences in clinical background, respiratory function, composite physiologic index, or pathological features between the groups; however, the degree of fibrosis on preoperative HRCT was significantly higher in the exacerbation group (P<0.003). The fibrosis score was higher on the opposite side to the lung cancer in the exacerbation group (P<0.05). Although it is difficult to predict postoperative acute IPF exacerbation, the degree and laterality of co-existing fibrosis seem to be predictors. (author)

  3. Test-retest variability of high resolution positron emission tomography (PET) imaging of cortical serotonin (5HT2A) receptors in older, healthy adults

    International Nuclear Information System (INIS)

    Chow, Tiffany W; Mamo, David C; Uchida, Hiroyuki; Graff-Guerrero, Ariel; Houle, Sylvain; Smith, Gwenn S; Pollock, Bruce G; Mulsant, Benoit H

    2009-01-01

    Position emission tomography (PET) imaging using [ 18 F]-setoperone to quantify cortical 5-HT 2A receptors has the potential to inform pharmacological treatments for geriatric depression and dementia. Prior reports indicate a significant normal aging effect on serotonin 5HT 2A receptor (5HT 2A R) binding potential. The purpose of this study was to assess the test-retest variability of [ 18 F]-setoperone PET with a high resolution scanner (HRRT) for measuring 5HT 2A R availability in subjects greater than 60 years old. Methods: Six healthy subjects (age range = 65–78 years) completed two [ 18 F]-setoperone PET scans on two separate occasions 5–16 weeks apart. The average difference in the binding potential (BP ND ) as measured on the two occasions in the frontal and temporal cortical regions ranged between 2 and 12%, with the lowest intraclass correlation coefficient in anterior cingulate regions. We conclude that the test-retest variability of [ 18 F]-setoperone PET in elderly subjects is comparable to that of [ 18 F]-setoperone and other 5HT 2A R radiotracers in younger subject samples

  4. Utility of the inspiratory phase in high-resolution computed tomography evaluations of pediatric patients with bronchiolitis obliterans after allogeneic bone marrow transplant: reducing patient radiation exposure

    International Nuclear Information System (INIS)

    Togni Filho, Paulo Henrique; Casagrande, Joao Luiz Marin; Lederman, Henrique Manoel; Universidade de Sao Paulo

    2017-01-01

    Objective: To evaluate the utility of the inspiratory phase in high-resolution computed tomography (HRCT) of the chest for the diagnosis of post-bone marrow transplantation bronchiolitis obliterans. Materials and Methods: This was a retrospective, observational, cross-sectional study. We selected patients of either gender who underwent bone marrow transplantation and chest HRCT between March 1, 2002 and December 12, 2014. Ages ranged from 3 months to 20.7 years. We included all examinations in which the HRCT was performed appropriately. The examinations were read by two radiologists, one with extensive experience in pediatric radiology and another in the third year of residency, who determined the presence or absence of the following imaging features: air trapping, bronchiectasis, alveolar opacities, nodules, and atelectasis. Results: A total of 222 examinations were evaluated (mean, 5.4 ± 4.5 examinations per patient). The expiratory phase findings were comparable to those obtained in the inspiratory phase, except in one patient, in whom a small uncharacteristic nodule was identified only in the inspiratory phase. Air trapping was identified in a larger number of scans in the expiratory phase than in the inspiratory phase, as was atelectasis, although the difference was statistically significant only for air trapping. Conclusion: In children being evaluated for post-bone marrow transplantation bronchiolitis obliterans, the inspiratory phase can be excluded from the chest HRCT protocol, thus reducing by half the radiation exposure in this population. (author)

  5. High Resolution Elevation Contours

    Data.gov (United States)

    Minnesota Department of Natural Resources — This dataset contains contours generated from high resolution data sources such as LiDAR. Generally speaking this data is 2 foot or less contour interval.

  6. An investigation of the potential of optical computed tomography for imaging of synchrotron-generated x-rays at high spatial resolution

    International Nuclear Information System (INIS)

    Doran, Simon J; Brochard, Thierry; Braeuer-Krisch, Elke; Adamovics, John; Krstajic, Nikola

    2010-01-01

    X-ray microbeam radiation therapy (MRT) is a novel form of treatment, currently in its preclinical stage, which uses microplanar x-ray beams from a synchrotron radiation source. It is important to perform accurate dosimetry on these microbeams, but, to date, there has been no accurate enough method available for making 3D dose measurements with isotropic, high spatial resolution to verify the results of Monte Carlo dose simulations. Here, we investigate the potential of optical computed tomography for satisfying these requirements. The construction of a simple optical CT microscopy (optical projection tomography) system from standard commercially available hardware is described. The measurement of optical densities in projection data is shown to be highly linear (r 2 = 0.999). The depth-of-field (DOF) of the imaging system is calculated based on the previous literature and measured experimentally using a commercial DOF target. It is shown that high quality images can be acquired despite the evident lack of telecentricity and despite DOF of the system being much lower than the sample diameter. Possible reasons for this are discussed. Results are presented for a complex irradiation of a 22 mm diameter cylinder of the radiochromic polymer PRESAGE(TM), demonstrating the exquisite 'dose-painting' abilities available in the MRT hutch of beamline ID-17 at the European Synchrotron Radiation Facility. Dose distributions in this initial experiment are equally well resolved on both an optical CT scan and a corresponding transmission image of radiochromic film, down to a line width of 83 μm (6 lp mm -1 ) with an MTF value of 0.40. A group of 33 μm wide lines was poorly resolved on both the optical CT and film images, and this is attributed to an incorrect exposure time calculation, leading to under-delivery of dose. Image artefacts in the optical CT scan are discussed. PRESAGE(TM) irradiated using the microbeam facility is proposed as a suitable material for producing

  7. High resolution computed tomography(HRCT) findings of a solitary pulmonary nodule : differential diagnosis of cancer and tuberculosis

    International Nuclear Information System (INIS)

    Kim, Hee Soo; Choe, Kyu Ok

    1996-01-01

    To evaluate the role of HRCT in the differentiation of Pulmonary tuberculosis and lung cancer, where the manifestation of disease is a solitary pulmonary nodule(SPN). Forty eight SPNs including 29 cancers proven by surgery(n=10), by bronchoscopic biopsy(n=7) and by fine needle aspiration biopsy(n=12), and 19 tuberculous nodules proven by surgery(n=4), by bronchoscopic biopsy(n=4), by fine needle aspiration biopsy(n=5), by a positive result in AFB culture without evidence of malignant cells(n=3), and by a decrease in size on serial plain chests despite negative AFB culture(n=3) were included. Scanning parameters for HRCT were 140 KVp, 170 mA, 1.5 mm collimation, 3 sec scanning time, and a high spatial frequency algorithm was used. With regard to the marginal features of nodules, the findings more commonly observed in malignant nodules were greater average length of the longest spicule(5.35 ± 3.19 mm versus 2.75 ± 1.56 mm), and more commonspiculated nodules greater than 3 cm in diameter, 16(55%) versus 2(10.5%)(p<0.05). Regarding the internal characteristics of nodules and perinodular parenchymal changes, the findings more commonly observed in cases of cancer were air-bronchograms within nodules(14 ; 48.3%) and interlobar fissure puckering (6 ; 20.7%), whereas in tuberculosis cases the most common findings were low density of nodule(16 ; 84.2%), cavitation(12 ; 63.1%), and perinodular focal lung hypodensity(5 ; 26.3%), (p<0.05). no statstically significant difference was observed between the incidence of satellite lesion of tuberculous(73.7%) and of malignant nodules(34.5%). However, perilobular nodules or bronchovascular bundle thickening s were more commonly observed in the satellite lesions of malignant nodules(9 ; 90%), whereas centrilobular nodules or lobular consolidation were more commonly observed in those of tuberculous nodules(12 ; 85.7%), (p<0.05). HRCT provides detailed information concerning perinodular parenchymal changes and characteristics of

  8. Metabolomics of Breast Cancer Using High-Resolution Magic Angle Spinning Magnetic Resonance Spectroscopy: Correlations with 18F-FDG Positron Emission Tomography-Computed Tomography, Dynamic Contrast-Enhanced and Diffusion-Weighted Imaging MRI.

    Science.gov (United States)

    Yoon, Haesung; Yoon, Dahye; Yun, Mijin; Choi, Ji Soo; Park, Vivian Youngjean; Kim, Eun-Kyung; Jeong, Joon; Koo, Ja Seung; Yoon, Jung Hyun; Moon, Hee Jung; Kim, Suhkmann; Kim, Min Jung

    2016-01-01

    Our goal in this study was to find correlations between breast cancer metabolites and conventional quantitative imaging parameters using high-resolution magic angle spinning (HR-MAS) magnetic resonance spectroscopy (MRS) and to find breast cancer subgroups that show high correlations between metabolites and imaging parameters. Between August 2010 and December 2013, we included 53 female patients (mean age 49.6 years; age range 32-75 years) with a total of 53 breast lesions assessed by the Breast Imaging Reporting and Data System. They were enrolled under the following criteria: breast lesions larger than 1 cm in diameter which 1) were suspicious for malignancy on mammography or ultrasound (US), 2) were pathologically confirmed to be breast cancer with US-guided core-needle biopsy (CNB) 3) underwent 3 Tesla MRI with dynamic contrast-enhanced (DCE) and diffusion-weighted imaging (DWI) and positron emission tomography-computed tomography (PET-CT), and 4) had an attainable immunohistochemistry profile from CNB. We acquired spectral data by HR-MAS MRS with CNB specimens and expressed the data as relative metabolite concentrations. We compared the metabolites with the signal enhancement ratio (SER), maximum standardized FDG uptake value (SUV max), apparent diffusion coefficient (ADC), and histopathologic prognostic factors for correlation. We calculated Spearman correlations and performed a partial least squares-discriminant analysis (PLS-DA) to further classify patient groups into subgroups to find correlation differences between HR-MAS spectroscopic values and conventional imaging parameters. In a multivariate analysis, the PLS-DA models built with HR-MAS MRS metabolic profiles showed visible discrimination between high and low SER, SUV, and ADC. In luminal subtype breast cancer, compared to all cases, high SER, ADV, and SUV were more closely clustered by visual assessment. Multiple metabolites were correlated with SER and SUV in all cases. Multiple metabolites showed

  9. Metabolomics of Breast Cancer Using High-Resolution Magic Angle Spinning Magnetic Resonance Spectroscopy: Correlations with 18F-FDG Positron Emission Tomography-Computed Tomography, Dynamic Contrast-Enhanced and Diffusion-Weighted Imaging MRI.

    Directory of Open Access Journals (Sweden)

    Haesung Yoon

    Full Text Available Our goal in this study was to find correlations between breast cancer metabolites and conventional quantitative imaging parameters using high-resolution magic angle spinning (HR-MAS magnetic resonance spectroscopy (MRS and to find breast cancer subgroups that show high correlations between metabolites and imaging parameters.Between August 2010 and December 2013, we included 53 female patients (mean age 49.6 years; age range 32-75 years with a total of 53 breast lesions assessed by the Breast Imaging Reporting and Data System. They were enrolled under the following criteria: breast lesions larger than 1 cm in diameter which 1 were suspicious for malignancy on mammography or ultrasound (US, 2 were pathologically confirmed to be breast cancer with US-guided core-needle biopsy (CNB 3 underwent 3 Tesla MRI with dynamic contrast-enhanced (DCE and diffusion-weighted imaging (DWI and positron emission tomography-computed tomography (PET-CT, and 4 had an attainable immunohistochemistry profile from CNB. We acquired spectral data by HR-MAS MRS with CNB specimens and expressed the data as relative metabolite concentrations. We compared the metabolites with the signal enhancement ratio (SER, maximum standardized FDG uptake value (SUV max, apparent diffusion coefficient (ADC, and histopathologic prognostic factors for correlation. We calculated Spearman correlations and performed a partial least squares-discriminant analysis (PLS-DA to further classify patient groups into subgroups to find correlation differences between HR-MAS spectroscopic values and conventional imaging parameters.In a multivariate analysis, the PLS-DA models built with HR-MAS MRS metabolic profiles showed visible discrimination between high and low SER, SUV, and ADC. In luminal subtype breast cancer, compared to all cases, high SER, ADV, and SUV were more closely clustered by visual assessment. Multiple metabolites were correlated with SER and SUV in all cases. Multiple metabolites

  10. Technical note: a landmark-based approach to the study of the ear ossicles using ultra-high-resolution X-ray computed tomography data.

    Science.gov (United States)

    Schmidt, Jodi L; Cole, Theodore M; Silcox, Mary T

    2011-08-01

    Previous study of the ear ossicles in Primates has demonstrated that they vary on both functional and phylogenetic bases. Such studies have generally employed two-dimensional linear measurements rather than three-dimensional data. The availability of Ultra- high-resolution X-ray computed tomography (UhrCT) has made it possible to accurately image the ossicles so that broadly accepted methodologies for acquiring and studying morphometric data can be applied. Using UhrCT data also allows for the ossicular chain to be studied in anatomical position, so that it is possible to consider the spatial and size relationships of all three bones. One issue impeding the morphometric study of the ear ossicles is a lack of broadly recognized landmarks. Distinguishing landmarks on the ossicles is difficult in part because there are only two areas of articulation in the ossicular chain, one of which (the malleus/incus articulation) has a complex three-dimensional form. A measurement error study is presented demonstrating that a suite of 16 landmarks can be precisely located on reconstructions of the ossicles from UhrCT data. Estimates of measurement error showed that most landmarks were highly replicable, with an average CV for associated interlandmark distances of less than 3%. The positions of these landmarks are chosen to reflect not only the overall shape of the bones in the chain and their relative positions, but also functional parameters. This study should provide a basis for further examination of the smallest bones in the body in three dimensions. Copyright © 2011 Wiley-Liss, Inc.

  11. Comparison of chest radiography and high-resolution computed tomography findings in early and low-grade coal worker's pneumoconiosis

    Energy Technology Data Exchange (ETDEWEB)

    Savranlar, A.; Altin, R.; Mahmutyazicioglu, K.; Ozdemir, H.; Kart, L.; Ozer, T.; Gundogdu, S. [Zonguldak Karaelmas University, Zonguldak (Turkey). Faculty of Medicine

    2004-08-01

    High-resolution computed tomography (HRCT) is more sensitive than chest X-ray (CXR) in the depiction of parenchymal abnormalities. The paper presents and compares CXR and HRCT findings in coal workers with and without early and low-grade coal worker's pneumoconiosis (CWP). 71 coal workers were enrolled in the study. HRCT's were graded according to Hosoda and Shida's Japanese classification. After grading, 67 workers with CXR profusion 0/0-2/2 were included in the study. Four patients with major opacity were excluded. Profusion 0/1 to 1/1 cases were accepted as early and profusion and 2/2 cases as low-grade pneumoconiosis. Discordance rate was found to be higher in the early pneumoconiosis cases with negative CXR than low-grade pneumoconiosis (60, 36 and 8%, respectively). When coal miners with normal CXR were evaluated by HRCT, six out of 10 cases were diagnosed as positive. In low-grade pneumoconiosis group, the number of patients with positive CXR but negative HRCT were low in comparison to patients with CXR negative and early pneumoconiosis findings. Most of the CXR category 0 patients (10/16) were diagnosed as category 1 by HRCT. Eleven cases diagnosed as CXR category 1 were diagnosed as category 0 (7/11) and category 2 (4/11) by HRCT. In CXR category 2 (eight cases), there were four cases diagnosed as category 1 by HRCT. Overall, discordance between CXR and HRCT was high, especially for CXR negative and early pneumoconiosis cases. The role of CXR in screening coal workers to detect early pneumoconiosis findings should be questioned. The authors suggest using HRCT as a standard screening method instead of CXR to distinguish between normal and early pneumoconiosis.

  12. Edema pulmonar hidrostático: aspectos na tomografia computadorizada de alta resolução Hydrostatic pulmonary edema: high-resolution computed tomography aspects

    Directory of Open Access Journals (Sweden)

    Cláudia Maria Cunha Ribeiro

    2006-12-01

    Full Text Available OBJETIVO: A proposta deste estudo foi caracterizar por meio de tomografia computadorizada de alta resolução do tórax as principais alterações pulmonares do edema pulmonar hidrostático. MÉTODOS: Foram analisadas, retrospectivamente, as tomografias de quinze pacientes com quadro clínico de edema pulmonar hidrostático, divididos em cinco principais grupos etiológicos: insuficiência cardíaca congestiva, valvulopatia mitral aguda, infarto agudo do miocárdio, miocardite e mediastinite fibrosante, tendo sido sete pacientes classificados no primeiro grupo e dois em cada um dos demais. RESULTADOS: Os principais achados do edema hidrostático foram opacidades em vidro fosco (100%, espessamento dos septos interlobulares (100%, derrame pleural (87% e espessamento do interstício peribroncovascular (80%. Outros achados menos comuns foram aumento do calibre dos vasos, consolidações e nódulos do espaço aéreo. CONCLUSÃO: O padrão predominante encontrado nos pacientes estudados foi o de opacidades em vidro fosco associadas a espessamento dos septos interlobulares (padrão de pavimentação em mosaico, com derrame pleural bilateral, predominante à direita.OBJECTIVE: This study aimed to use high-resolution computed tomography scans of the chest to characterize the principal alterations occurring in cases of hydrostatic pulmonary edema. METHODS: A retrospective analysis was made of the tomography scans of 15 patients presenting clinical profiles of hydrostatic pulmonary edema. The cases were divided into five groups by etiology: congestive heart failure (n = 7; acute mitral valve disease (n = 2; acute myocardial infarction (n = 2; myocarditis (n = 2; and fibrosing mediastinitis (n = 2. RESULTS: The principal findings in the cases of hydrostatic pulmonary edema were ground-glass opacities (in 100%, interlobular septal thickening (in 100%, pleural effusion (in 87% and peribronchovascular interstitial thickening (in 80%. Other, less common

  13. High resolution solar observations

    International Nuclear Information System (INIS)

    Title, A.

    1985-01-01

    Currently there is a world-wide effort to develop optical technology required for large diffraction limited telescopes that must operate with high optical fluxes. These developments can be used to significantly improve high resolution solar telescopes both on the ground and in space. When looking at the problem of high resolution observations it is essential to keep in mind that a diffraction limited telescope is an interferometer. Even a 30 cm aperture telescope, which is small for high resolution observations, is a big interferometer. Meter class and above diffraction limited telescopes can be expected to be very unforgiving of inattention to details. Unfortunately, even when an earth based telescope has perfect optics there are still problems with the quality of its optical path. The optical path includes not only the interior of the telescope, but also the immediate interface between the telescope and the atmosphere, and finally the atmosphere itself

  14. Investigation of optimal display size for detecting ground-glass opacity on high resolution computed tomography using a new digital contrast-detail phantom

    International Nuclear Information System (INIS)

    Yamaguchi, Michihiro; Fujita, Hideki; Bessho, Yuichi; Inoue, Tatsuro; Asai, Yoshiyuki; Murase, Kenya

    2011-01-01

    The purpose of this study was to clarify the relationship between display sizes of high resolution computed tomography (HRCT) images for detecting ground-glass opacity (GGO) and observer performance using a digital contrast-detail (d-CD) phantom. A structure of the d-CD phantom was determined on the basis of the actual images of GGOs and background noises of 22 patients who were diagnosed as GGO by chest HRCT. The d-CD phantom has a 512 × 512 matrix in size and has total of 100 holes: the diameter of these holes increases stepwise from 2 to 20 pixels with 2 pixels interval in a vertical direction and the CT value varies stepwise from 2 to 200 HU in a horizontal direction. The observer performance study was carried out for three different display sizes (30 cm × 30 cm as an enlarged size, 13 cm × 13 cm as an original size, and 7 cm × 7 cm as a reduced size) using a 2-megapixels LCD monitor, and it was analyzed using Friedman and Wilcoxon statistical tests. As a result, the observer performance for the original display and the reduced display sizes was superior to that for the enlarged size (P = 0.006 and 0.037 for the original display and the reduced display sizes, respectively), whereas there was no significant difference between the original display and reduced display sizes (P = 0.77). The d-CD phantom enables a short-term evaluation of observer performance and is useful in analyzing relationship between display size and observer performance.

  15. High-resolution computed tomography findings of influenza virus pneumonia. A comparative study between seasonal and novel (H1N1) influenza virus pneumonia

    International Nuclear Information System (INIS)

    Tanaka, Nobuyuki; Kunihiro, Yoshie; Matsunaga, Naofumi; Hasegawa, Shunji; Ichiyama, Takashi; Emoto, Takuya; Suda, Hiroki

    2012-01-01

    The purpose of this study was to evaluate the high-resolution computed tomography (HRCT) findings of novel influenza virus (n-IFV) pneumonia and compare them with the findings for seasonal (s-IFV) pneumonia. We evaluated 29 cases of pure IFV pneumonia that occurred between 1990 and 2010. We evaluated the existence, extent, and patterns of HRCT findings and compared these features between s-IFV and n-IFV. Consolidation was less frequent in s-IFV than in n-IFV (40.0 vs. 84.2%, respectively; p=0.014). Consolidation with a loss of volume was frequent in n-IFV (62.5%). There was no significant difference in the occurrence of ground-glass opacity (GGO) between s-IFV and n-IFV (100 vs. 84.2%, respectively). GGO with reticular opacities was more frequent in s-IFV than in n-IFV (70.0 vs. 25.0%, respectively; p=0.024). The frequency of nodules was not significantly different between the two groups. The mosaic pattern was more frequent in s-IFV than in n-IFV patients (80.0 vs. 15.8%, respectively; p=0.0007). Mucoid impaction was more frequent in patients with n-IFV than with s-IFV (52.6 vs. 10.0%, respectively; p=0.025). Consolidation and mucoid impaction were more frequent in n-IFV, whereas GGO with reticular opacities and a mosaic pattern occurred more frequently in s-IFV; otherwise, there were no significant differences between the two groups. (author)

  16. Preoperative differentiation between T1a and ≥T1b gallbladder cancer: combined interpretation of high-resolution ultrasound and multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Joo, Ijin; Baek, Jee Hyun; Kim, Jung Hoon; Han, Joon Koo; Choi, Byung Ihn; Lee, Jae Young; Park, Hee Sun

    2014-01-01

    To determine the diagnostic value of combined interpretation of high-resolution ultrasound (HRUS) and multidetector-row computed tomography (MDCT) for preoperative differentiation between T1a and ≥T1b gallbladder (GB) cancer. Eighty-seven patients with pathologically confirmed GB cancers (T1a, n = 15; ≥T1b, n = 72), who preoperatively underwent both HRUS and MDCT, were included in this retrospective study. Two reviewers independently determined the T-stages of the GB cancers on HRUS and MDCT using a five-point confidence scale (5, definitely T1a; 1, definitely ≥T1b). For individual modality interpretation, the lesions with scores ≥4 were classified as T1a, and, for combined modality interpretation, the lesions with all scores ≥4 in both modalities were classified as T1a. The McNemar test was used to compare diagnostic performance. The diagnostic accuracy of differentiation between T1a and ≥T1b GB cancer was higher using combined interpretation (90.8 % and 88.5 % for reviewers 1 and 2, respectively) than individual interpretation of HRUS (82.8 % and 83.9 %) or MDCT (74.7 % and 82.8 %) (P < 0.05, reviewer 1). Combined interpretations demonstrated 100 % specificity for both reviewers, which was significantly higher than individual interpretations (P < 0.05, both reviewers). Combined HRUS and MDCT interpretation may improve the diagnostic accuracy and specificity for differentiating between T1a and ≥T1b GB cancers. circle Differentiating between T1a and ≥T1b gallbladder cancer can help surgical planning. (orig.)

  17. Comparison of high-resolution and standard zoom imaging modes in cone beam computed tomography for detection of longitudinal root fracture: An in vitro study

    International Nuclear Information System (INIS)

    Taramsari, Mehran; Kajan, Zahra Dalili; Bashizadeh, Parinaz; Salamat, Fatemeh

    2013-01-01

    The purpose of this study was to compare the efficacy of two imaging modes in a cone beam computed tomography (CBCT) system in detecting root fracture in endodontically-treated teeth with fiber posts or screw posts by selecting two fields of view. In this study, 78 endodontically-treated single canal premolars were included. A post space was created in all of them. Then the teeth were randomly set in one of 6 artificial dental arches. In 39 of the 78 teeth set in the 6 dental arches, a root fracture was intentionally created. Next, a fiber post and a screw post were cemented into 26 teeth having equal the root fractures. High resolution (HiRes) and standard zoom images were provided by a CBCT device. Upon considering the reconstructed images, two observers in agreement with each other confirmed the presence or absence of root fracture. A McNemar test was used for comparing the results of the two modes. The frequency of making a correct diagnosis using the HiRes zoom imaging mode was 71.8% and in standard zoom was 59%. The overall sensitivity and specificity in diagnosing root fracture in the HiRes mode were 71.79% and 46.15% and in the standard zoom modes were 58.97% and 33.33%, respectively. There were no significant differences between the diagnostic values of the two imaging modes used in the diagnosis of root fracture or in the presence of root canal restorations. In both modes, the most true-positive results were reported in the post space group.

  18. Distal radius plate of CFR-PEEK has minimal effect compared to titanium plates on bone parameters in high-resolution peripheral quantitative computed tomography: a pilot study.

    Science.gov (United States)

    de Jong, Joost J A; Lataster, Arno; van Rietbergen, Bert; Arts, Jacobus J; Geusens, Piet P; van den Bergh, Joop P W; Willems, Paul C

    2017-02-27

    Carbon-fiber-reinforced poly-ether-ether-ketone (CFR-PEEK) has superior radiolucency compared to other orthopedic implant materials, e.g. titanium or stainless steel, thus allowing metal-artifact-free postoperative monitoring by computed tomography (CT). Recently, high-resolution peripheral quantitative CT (HRpQCT) proved to be a promising technique to monitor the recovery of volumetric bone mineral density (vBMD), micro-architecture and biomechanical parameters in stable conservatively treated distal radius fractures. When using HRpQCT to monitor unstable distal radius fractures that require volar distal radius plating for fixation, radiolucent CFR-PEEK plates may be a better alternative to currently used titanium plates to allow for reliable assessment. In this pilot study, we assessed the effect of a volar distal radius plate made from CFR-PEEK on bone parameters obtained from HRpQCT in comparison to two titanium plates. Plates were instrumented in separate cadaveric human fore-arms (n = 3). After instrumentation and after removal of the plates duplicate HRpQCT scans were made of the region covered by the plate. HRpQCT images were visually checked for artifacts. vBMD, micro-architectural and biomechanical parameters were calculated, and compared between the uninstrumented and instrumented radii. No visible image artifacts were observed in the CFR-PEEK plate instrumented radius, and errors in bone parameters ranged from -3.2 to 2.6%. In the radii instrumented with the titanium plates, severe image artifacts were observed and errors in bone parameters ranged between -30.2 and 67.0%. We recommend using CFR-PEEK plates in longitudinal in vivo studies that monitor the healing process of unstable distal radius fractures treated operatively by plating or bone graft ingrowth.

  19. Chest Abnormalities in Juvenile-Onset Mixed Connective Tissue Disease: Assessment with High-Resolution Computed Tomography and Pulmonary Function Tests

    International Nuclear Information System (INIS)

    Aaloekken, T.M.; Mynarek, G.; Kolbenstvedt, A.; Lilleby, V.; Foerre, Oe.; Soeyseth, V.; Pripp, A.H.; Johansen, B.

    2009-01-01

    Background: Mixed connective tissue disease (MCTD) is associated with several chest manifestations. Only a few studies have focused on chest manifestations in juvenile-onset MCTD (jMCTD), and the true prevalence of pulmonary abnormalities on high-resolution computed tomography (HRCT) in these patients is unknown. Purpose: To investigate the occurrence of pulmonary abnormalities in jMCTD with particular reference to interstitial lung disease (ILD), and to evaluate a possible association between pulmonary findings and disease-related variables. Material and Methods: Twenty-four childhood-onset MCTD patients with median disease duration of 10.5 years (range 1-21 years) were investigated in a cross-sectional study by means of HRCT, pulmonary function tests (PFT), and clinical assessment. Results: Discrete ILD was identified in six patients (25%). Median extent of ILD was 2.0%, and all except one of the patients had very mild disease in which 5% or less of the parenchyma was affected. The CT features of fibrosis were mainly microcystic and fine intralobular. The most frequently abnormal PFT was carbon monoxide uptake from the lung, which was abnormal in 33% of the patients. PFT and disease duration were not significantly associated with HRCT findings of ILD. Conclusion: The prevalence of ILD in childhood-onset MCTD patients was lower than previously believed. In most of the patients with ILD, the findings were subtle and without clinical correlation. The results suggest a low extent of ILD in childhood-onset MCTD, even after long-term disease duration

  20. Rheumatoid arthritis-associated interstitial lung disease: lung inflammation evaluated with high resolution computed tomography scan is correlated to rheumatoid arthritis disease activity.

    Science.gov (United States)

    Pérez-Dórame, Renzo; Mejía, Mayra; Mateos-Toledo, Heidegger; Rojas-Serrano, Jorge

    2015-01-01

    To describe the association between rheumatoid arthritis disease activity (RA) and interstitial lung damage (inflammation and fibrosis), in a group of patients with rheumatoid arthritis-associated interstitial lung disease (RA-ILD). A retrospective study of RA patients with interstitial lung disease (restrictive pattern in lung function tests and evidence of interstitial lung disease in high resolution computed tomography (HRCT)). Patients were evaluated to exclude other causes of pulmonary disease. RA disease activity was measured with the CDAI index. Interstitial lung inflammation and fibrosis were determined by Kazerooni scale. We compared Kazerooni ground-glass score with the nearest CDAI score to HRCT date scan of the first medical evaluation at our institution. In nine patients, we compared the first ground-glass score with a second one after treatment with DMARDs and corticosteroids. Spearman's rank correlation coefficient was used to evaluate association between RA disease activity and the Kazerooni ground-glass and fibrosis scores. Thirty-four patients were included. A positive correlation between CDAI and ground-glass scores was found (rs=0.3767, P<0.028). Fibrosis and CDAI scores were not associated (rs=-0.0747, P<0.6745). After treatment, a downward tendency in the ground-glass score was observed (median [IQR]): (2.33 [2,3] vs. 2 [1.33-2.16]), P<0.056, along with a lesser CDAI score (27 [8-43] vs. 9 [5-12]), P<0.063. There is a correlation between RA disease activity and ground-glass appearance in the HRCT of RA-ILD patients. These results suggest a positive association between RA disease activity and lung inflammation in RA-ILD. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  1. Rostrocaudal gradients of dopamine D2/3 receptor binding in striatal subregions measured with [11C]raclopride and high-resolution positron emission tomography

    DEFF Research Database (Denmark)

    Alakurtti, Kati; Johansson, Jarkko J; Tuokkola, Terhi

    2013-01-01

    scanned with brain-dedicated high-resolution research tomography (HRRT, Siemens Medical Solutions, Knoxville, TN, USA) and [(11)C]raclopride. Coronally defined regions of interest (ROIs) of the caudate nucleus, putamen and ventral striatum (VST) were sampled plane-by-plane, 1.5mm apart, on spatially...... observed in the VST. The novelty of this study lies in the presentation, for the first time, of the D2/3 receptor binding gradients in each striatal subregion in the brains of living healthy humans. The high spatial resolution provided by HRRT enables frequent sampling of BPND along the longitudinal extent...

  2. UT-CT: A National Resource for Applications of High-Resolution X-ray Computed Tomography in the Geological Sciences

    Science.gov (United States)

    Carlson, W. D.; Ketcham, R. A.; Rowe, T. B.

    2002-12-01

    An NSF-sponsored (EAR-IF) shared multi-user facility dedicated to research applications of high-resolution X-ray computed tomography (CT) in the geological sciences has been in operation since 1997 at the University of Texas at Austin. The centerpiece of the facility is an industrial CT scanner custom-designed for geological applications. Because the instrument can optimize trade-offs among penetrating ability, spatial resolution, density discrimination, imaging modes, and scan times, it can image a very broad range of geological specimens and materials, and thus offers significant advantages over medical scanners and desktop microtomographs. Two tungsten-target X-ray sources (200-kV microfocal and 420-kV) and three X-ray detectors (image-intensifier, high-sensitivity cadmium tungstate linear array, and high-resolution gadolinium-oxysulfide radiographic line scanner) can be used in various combinations to meet specific imaging goals. Further flexibility is provided by multiple imaging modes: second-generation (translate-rotate), third-generation (rotate-only; centered and variably offset), and cone-beam (volume CT). The instrument can accommodate specimens as small as about 1 mm on a side, and as large as 0.5 m in diameter and 1.5 m tall. Applications in petrology and structural geology include measuring crystal sizes and locations to identify mechanisms governing the kinetics of metamorphic reactions; visualizing relationships between alteration zones and abundant macrodiamonds in Siberian eclogites to elucidate metasomatic processes in the mantle; characterizing morphologies of spiral inclusion trails in garnet to test hypotheses of porphyroblast rotation during growth; measuring vesicle size distributions in basaltic flows for determination of elevation at the time of eruption to constrain timing and rates of continental uplift; analysis of the geometry, connectivity, and tortuosity of migmatite leucosomes to define the topology of melt flow paths, for numerical

  3. High resolution drift chambers

    International Nuclear Information System (INIS)

    Va'vra, J.

    1985-07-01

    High precision drift chambers capable of achieving less than or equal to 50 μm resolutions are discussed. In particular, we compare so called cool and hot gases, various charge collection geometries, several timing techniques and we also discuss some systematic problems. We also present what we would consider an ''ultimate'' design of the vertex chamber. 50 refs., 36 figs., 6 tabs

  4. Detectors for high resolution dynamic pet

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.; Huesman, R.H.

    1983-05-01

    This report reviews the motivation for high spatial resolution in dynamic positron emission tomography of the head and the technical problems in realizing this objective. We present recent progress in using small silicon photodiodes to measure the energy deposited by 511 keV photons in small BGO crystals with an energy resolution of 9.4% full-width at half-maximum. In conjunction with a suitable phototube coupled to a group of crystals, the photodiode signal to noise ratio is sufficient for the identification of individual crystals both for conventional and time-of-flight positron tomography

  5. Interactively variable isotropic resolution in computed tomography

    International Nuclear Information System (INIS)

    Lapp, Robert M; Kyriakou, Yiannis; Kachelriess, Marc; Wilharm, Sylvia; Kalender, Willi A

    2008-01-01

    An individual balancing between spatial resolution and image noise is necessary to fulfil the diagnostic requirements in medical CT imaging. In order to change influencing parameters, such as reconstruction kernel or effective slice thickness, additional raw-data-dependent image reconstructions have to be performed. Therefore, the noise versus resolution trade-off is time consuming and not interactively applicable. Furthermore, isotropic resolution, expressed by an equivalent point spread function (PSF) in every spatial direction, is important for the undistorted visualization and quantitative evaluation of small structures independent of the viewing plane. Theoretically, isotropic resolution can be obtained by matching the in-plane and through-plane resolution with the aforementioned parameters. Practically, however, the user is not assisted in doing so by current reconstruction systems and therefore isotropic resolution is not commonly achieved, in particular not at the desired resolution level. In this paper, an integrated approach is presented for equalizing the in-plane and through-plane spatial resolution by image filtering. The required filter kernels are calculated from previously measured PSFs in x/y- and z-direction. The concepts derived are combined with a variable resolution filtering technique. Both approaches are independent of CT raw data and operate only on reconstructed images which allows for their application in real time. Thereby, the aim of interactively variable, isotropic resolution is achieved. Results were evaluated quantitatively by measuring PSFs and image noise, and qualitatively by comparing the images to direct reconstructions regarded as the gold standard. Filtered images matched direct reconstructions with arbitrary reconstruction kernels with standard deviations in difference images of typically between 1 and 17 HU. Isotropic resolution was achieved within 5% of the selected resolution level. Processing times of 20-100 ms per frame

  6. High resolution data acquisition

    Science.gov (United States)

    Thornton, Glenn W.; Fuller, Kenneth R.

    1993-01-01

    A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock (38) pulse train (37) and analog circuitry (44) for generating a triangular wave (46) synchronously with the pulse train (37). The triangular wave (46) has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter (18, 32) forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter (26) counts the clock pulse train (37) during the interval to form a gross event interval time. A computer (52) then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.

  7. High resolution CT in diffuse lung disease

    International Nuclear Information System (INIS)

    Webb, W.R.

    1995-01-01

    High resolution CT (computerized tomography) was discussed in detail. The conclusions were HRCT is able to define lung anatomy at the secondary lobular level and define a variety of abnormalities in patients with diffuse lung diseases. Evidence from numerous studies indicates that HRCT can play a major role in the assessment of diffuse infiltrative lung disease and is indicate clinically (95 refs.)

  8. High resolution CT in diffuse lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Webb, W R [California Univ., San Francisco, CA (United States). Dept. of Radiology

    1996-12-31

    High resolution CT (computerized tomography) was discussed in detail. The conclusions were HRCT is able to define lung anatomy at the secondary lobular level and define a variety of abnormalities in patients with diffuse lung diseases. Evidence from numerous studies indicates that HRCT can play a major role in the assessment of diffuse infiltrative lung disease and is indicate clinically (95 refs.).

  9. High-resolution optical coherence tomography using broadband light source with strain-controlled InAs/GaAs quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Tsubaki, Ippei; Harada, Yukihiro; Kita, Takashi [Department of Electrical and Electronic Engineering, Graduate School of Engineering, Kobe University, 1-1 Rokkodai, Nada, Kobe 657-8501 (Japan)

    2012-12-15

    Recently, there has been an increasing interest in broadband light sources to develop a biomolecular imaging technique called optical coherence tomography (OCT). We fabricated superluminescent diodes (SLDs) using three kinds of quantum dot (QD) layers with different emission wavelength in the active region. The emission wavelength was controlled by reducing the strain in QDs by using In{sub 0.1}Ga{sub 0.9}As strain-reducing layer. The SLD device showed a broad electroluminescence spectrum with the center wavelength of 1104 nm and the spectral linewidth of 122 nm at the injection of 40 mA, which corresponds to the theoretical axial resolution of 4.4 {mu}m. To estimate the actual resolution of the OCT system using fabricated SLD, we measured the interference signal in the Michelson interferometer. An axial resolution of 5.4 {mu}m, which is close to the theoretical limit, was obtained (copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  10. High resolution photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Arko, A.J.

    1988-01-01

    Photoelectron Spectroscopy (PES) covers a very broad range of measurements, disciplines, and interests. As the next generation light source, the FEL will result in improvements over the undulator that are larger than the undulater improvements over bending magnets. The combination of high flux and high inherent resolution will result in several orders of magnitude gain in signal to noise over measurements using synchrotron-based undulators. The latter still require monochromators. Their resolution is invariably strongly energy-dependent so that in the regions of interest for many experiments (h upsilon > 100 eV) they will not have a resolving power much over 1000. In order to study some of the interesting phenomena in actinides (heavy fermions e.g.) one would need resolving powers of 10 4 to 10 5 . These values are only reachable with the FEL

  11. High-resolution computed tomography findings of swine-origin influenza A (H1N1) virus (S-OIV) infection: comparison with scrub typhus

    International Nuclear Information System (INIS)

    Jo, Bang Sil; Lee, In Jae; Lee, Kwanseop; Im, Hyoung June

    2012-01-01

    Background. Swine-origin influenza A (H1N1) virus (S-OIV) infection and scrub typhus, also known as tsutsugamushi disease can manifest as acute respiratory illnesses, particularly during the late fall or early winter, with similar radiographic findings, such as a predominance of ground-glass opacity (GGO). Purpose. To differentiate S-OIV infection from scrub typhus using high-resolution computed tomography (HRCT). Material and Methods. We retrospectively reviewed the HRCT findings of 14 patients with S-OIV infection and 10 patients with scrub typhus. We assessed the location, cross-sectional distribution, and the presence of a peribronchovascular distribution of GGO and consolidations on HRCT. We also assessed the presence of interlobular septal thickening, bronchial wall thickening, pneumothorax, pneumomediastinum, pleural effusion, and mediastinal or axillary lymph node enlargement. Results. Scrub typhus was more common than S-OIV in elderly patients (P < 0.001). The monthly incidences of S-OIV and scrub typhus infection reached a peak between October and November. About 86% of S-OIV patients and 80% of scrub typhus patients presented with GGO. About 67% of the GGO lesions in S-OIV had a peribronchovascular distribution, but this was absent in scrub typhus (P = 0.005). Consolidation (93% vs. 10%, P < 0.001) and bronchial wall thickening (43% vs. 0%, P = 0.024) were more frequent in S-OIV infection than scrub typhus. Interlobular septal thickening (90% vs. 36%, P = 0.013) and axillary lymphadenopathy (90% vs. 0%, P < 0.001) were more common in scrub typhus than S-OIV infection. Conclusion. There was considerable overlap in HRCT findings between S-OIV infection and scrub typhus. However, S-OIV showed a distinctive peribronchovascular distribution of GGO lesions. Consolidation and bronchial wall thickening were seen more frequently in S-OIV infection, whereas interlobular septal thickening and axillary lymphadenopathy were more common in scrub typhus. Thus, CT could

  12. The summit part of Mount Etna revealed by High Resolution DC Electrical Resistivity Tomography coupled with complementary geophysical and soil gas techniques

    Science.gov (United States)

    Finizola, Anthony; Ricci, Tullio; Antoine, Raphael; Delcher, Eric; Peltier, Aline; Bernard, Julien; Brothelande, Elodie; Fargier, Yannick; Fauchard, Cyrille; Foucart, Brice; Gailler, Lydie; Gusset, Rachel; Lazarte, Ivonne; Martin, Erwan; Mézon, Cécile; Portal, Angélie; Poret, Matthieu; Rossi, Matteo

    2016-04-01

    In the framework of the EC FP7 project "MEDiterranean SUpersite Volcanoes", one profile coupling DC electrical resistivity tomography (Pole-Dipole configuration with a remote electrode located between 8-10 km from the middle of the different acquisitions, 64 electrodes and 40 m spacing between the electrodes), self-potential, soil CO2 degassing, Radon measurements and sub-surface (30cm depth) temperature have been performed between June 25th and July 13th 2015. This profile, NE-SW direction, crossed the summit part of Mount Etna. A total 5720m of profile was performed, with a roll along protocol of 1/4 of the dispositive, for each new acquisitions. A total of 6 acquisitions was made to complete the entire profile. For the first time in the world, a multi-electrodes DC ERT profile, of high resolution (40 m of spacing between the electrodes) reached, thanks to a pole-dipole configuration, 900m for the depth of investigation. The ERT profile clearly evidences the hydrothermal system of Mount Etna: the lowest resistivity values are associated with a large scale positive self-potential anomaly, and smaller wavelength anomalies for temperature, CO2 concentration and Radon, in the area where the electrical conductor reach the surface. Structural discontinuities such as the Elliptic crater, was clearly evidenced by a sharp decrease of the self-potential values in the inner part of this crater. The striking result of this profile is the presence of a resistive body located just below the NE crater. This structure displays the highest degassing values of the entire profile. We interpret this resistive body as a consequence of the thermic over-heated plume rising from the top of the shallow feeding system. Indeed, above several hundred of degrees Celsuis, it is impossible to consider rain water infiltration and the presence of a wet hydrothermal system. The consequence would be therefore to obtain this resistive body, centred on the area of main heat transfer. Above this

  13. High-resolution computed tomography findings of swine-origin influenza A (H1N1) virus (S-OIV) infection: comparison with scrub typhus

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Bang Sil; Lee, In Jae; Lee, Kwanseop [Dept. of Radiology, Hallym Univ. College of Medicine, Seoul (Korea, Republic of)], E-mail: ijlee2003@medimail.co.kr; Im, Hyoung June [Dept. of Occupational Medicine, Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    2012-07-15

    Background. Swine-origin influenza A (H1N1) virus (S-OIV) infection and scrub typhus, also known as tsutsugamushi disease can manifest as acute respiratory illnesses, particularly during the late fall or early winter, with similar radiographic findings, such as a predominance of ground-glass opacity (GGO). Purpose. To differentiate S-OIV infection from scrub typhus using high-resolution computed tomography (HRCT). Material and Methods. We retrospectively reviewed the HRCT findings of 14 patients with S-OIV infection and 10 patients with scrub typhus. We assessed the location, cross-sectional distribution, and the presence of a peribronchovascular distribution of GGO and consolidations on HRCT. We also assessed the presence of interlobular septal thickening, bronchial wall thickening, pneumothorax, pneumomediastinum, pleural effusion, and mediastinal or axillary lymph node enlargement. Results. Scrub typhus was more common than S-OIV in elderly patients (P < 0.001). The monthly incidences of S-OIV and scrub typhus infection reached a peak between October and November. About 86% of S-OIV patients and 80% of scrub typhus patients presented with GGO. About 67% of the GGO lesions in S-OIV had a peribronchovascular distribution, but this was absent in scrub typhus (P = 0.005). Consolidation (93% vs. 10%, P < 0.001) and bronchial wall thickening (43% vs. 0%, P = 0.024) were more frequent in S-OIV infection than scrub typhus. Interlobular septal thickening (90% vs. 36%, P = 0.013) and axillary lymphadenopathy (90% vs. 0%, P < 0.001) were more common in scrub typhus than S-OIV infection. Conclusion. There was considerable overlap in HRCT findings between S-OIV infection and scrub typhus. However, S-OIV showed a distinctive peribronchovascular distribution of GGO lesions. Consolidation and bronchial wall thickening were seen more frequently in S-OIV infection, whereas interlobular septal thickening and axillary lymphadenopathy were more common in scrub typhus. Thus, CT could

  14. An exploratory study of contrast agents for soft tissue visualization by means of high resolution X-ray computed tomography imaging.

    Science.gov (United States)

    Pauwels, E; Van Loo, D; Cornillie, P; Brabant, L; Van Hoorebeke, L

    2013-04-01

    High resolution X-ray computed tomography (CT), or microCT, is a promising and already widely used technique in various scientific fields. Also for histological purposes it has great potential. Although microCT has proven to be a valuable technique for the imaging of bone structures, the visualization of soft tissue structures is still an important challenge due to their low inherent X-ray contrast. One way to achieve contrast enhancement is to make use of contrast agents. However, contrary to light and electron microscopy, knowledge about contrast agents and staining procedures is limited for X-ray CT. The purpose of this paper is to identify useful X-ray contrast agents for soft tissue visualization, which can be applied in a simple way and are also suited for samples larger than (1 cm)(3) . And 28 chemical substances have been investigated. All chemicals were applied in the form of concentrated aqueous solutions in which the samples were immersed. First, strips of green Bacon were stained to evaluate contrast enhancement between muscle and adipose tissue. Furthermore it was also tested whether the contrast agents remained fixed in the tissue after staining by re-immersing them in water. Based on the results, 12 contrast agents were selected for further testing on postmortem mice hind legs, containing a variety of different tissues, including muscle, fat, bone, cartilage and tendons. It was evaluated whether the contrast agents allowed a clearer distinction between the different soft tissue structures present. Finally also penetration depth was measured. And 26 chemicals resulted in contrast enhancement between muscle and adipose tissue in the Bacon strips. Mercury(II)chloride (HgCl2 ), phosphotungstic acid (PTA), phosphomolybdic acid (PMA) and ammonium orthomolybdate ((NH4 )2 MoO4 ) remained fixed after re-immersion in water. The penetration tests showed that potassium iodide (KI) and sodium tungstate can be most efficiently used for large samples of the order

  15. High resolution (transformers.

    Science.gov (United States)

    Garcia-Souto, Jose A; Lamela-Rivera, Horacio

    2006-10-16

    A novel fiber-optic interferometric sensor is presented for vibrations measurements and analysis. In this approach, it is shown applied to the vibrations of electrical structures within power transformers. A main feature of the sensor is that an unambiguous optical phase measurement is performed using the direct detection of the interferometer output, without external modulation, for a more compact and stable implementation. High resolution of the interferometric measurement is obtained with this technique (transformers are also highlighted.

  16. A simulation study of high-resolution x-ray computed tomography imaging using irregular sampling with a photon-counting detector

    International Nuclear Information System (INIS)

    Lee, Seungwan; Choi, Yu-Na; Kim, Hee-Joung

    2013-01-01

    The purpose of this study was to improve the spatial resolution for the x-ray computed tomography (CT) imaging with a photon-counting detector using an irregular sampling method. The geometric shift-model of detector was proposed to produce the irregular sampling pattern and increase the number of samplings in the radial direction. The conventional micro-x-ray CT system and the novel system with the geometric shift-model of detector were simulated using analytic and Monte Carlo simulations. The projections were reconstructed using filtered back-projection (FBP), algebraic reconstruction technique (ART), and total variation (TV) minimization algorithms, and the reconstructed images were compared in terms of normalized root-mean-square error (NRMSE), full-width at half-maximum (FWHM), and coefficient-of-variation (COV). The results showed that the image quality improved in the novel system with the geometric shift-model of detector, and the NRMSE, FWHM, and COV were lower for the images reconstructed using the TV minimization technique in the novel system with the geometric shift-model of detector. The irregular sampling method produced by the geometric shift-model of detector can improve the spatial resolution and reduce artifacts and noise for reconstructed images obtained from an x-ray CT system with a photon-counting detector. -- Highlights: • We proposed a novel sampling method based on a spiral pattern to improve the spatial resolution. • The novel sampling method increased the number of samplings in the radial direction. • The spatial resolution was improved by the novel sampling method

  17. High resolution backscattering instruments

    International Nuclear Information System (INIS)

    Coldea, R.

    2001-01-01

    The principle of operation of indirect-geometry time-of-flight spectrometers are presented, including the IRIS at the ISIS spallation neutron source. The key features that make those types of spectrometers ideally suited for low-energy spectroscopy are: high energy resolution over a wide dynamic range, and simultaneous measurement over a large momentum transfer range provided by the wide angular detector coverage. To exemplify these features are discussed of single-crystal experiments of the spin dynamics in the two-dimensional frustrated quantum magnet Cs 2 CuCl 4 . (R.P.)

  18. Development of a large-area Multigap RPC with adequate spatial resolution for muon tomography

    Science.gov (United States)

    Wang, J.; Wang, Y.; Wang, X.; Zeng, M.; Xie, B.; Han, D.; Lyu, P.; Wang, F.; Li, Y.

    2016-11-01

    We study the performance of a large-area 2-D Multigap Resistive Plate Chamber (MRPC) designed for muon tomography with high spatial resolution. An efficiency up to 98% and a spatial resolution of around 270 μ m are obtained in cosmic ray and X-ray tests. The performance of the MRPC is also investigated for two working gases: standard gas and pure Freon. The result shows that the MRPC working in pure Freon can provide higher efficiency and better spatial resolution.

  19. Submicron Resolution Spectral-Domain Optical Coherence Tomography

    KAUST Repository

    Alarousu, Erkki

    2013-11-14

    Apparatuses and systems for submicron resolution spectral-domain optical coherence tomography (OCT) are disclosed. The system may use white light sources having wavelengths within 400-1000 nanometers, and achieve resolution below 1 .mu.m. The apparatus is aggregated into a unitary piece, and a user can connect the apparatus to a user provided controller and/or light source. The light source may be a supercontinuum source.

  20. High Time Resolution Astrophysics

    CERN Document Server

    Phelan, Don; Shearer, Andrew

    2008-01-01

    High Time Resolution Astrophysics (HTRA) is an important new window to the universe and a vital tool in understanding a range of phenomena from diverse objects and radiative processes. This importance is demonstrated in this volume with the description of a number of topics in astrophysics, including quantum optics, cataclysmic variables, pulsars, X-ray binaries and stellar pulsations to name a few. Underlining this science foundation, technological developments in both instrumentation and detectors are described. These instruments and detectors combined cover a wide range of timescales and can measure fluxes, spectra and polarisation. These advances make it possible for HTRA to make a big contribution to our understanding of the Universe in the next decade.

  1. High resolution ultrasonic densitometer

    International Nuclear Information System (INIS)

    Dress, W.B.

    1983-01-01

    The velocity of torsional stress pulses in an ultrasonic waveguide of non-circular cross section is affected by the temperature and density of the surrounding medium. Measurement of the transit times of acoustic echoes from the ends of a sensor section are interpreted as level, density, and temperature of the fluid environment surrounding that section. This paper examines methods of making these measurements to obtain high resolution, temperature-corrected absolute and relative density and level determinations of the fluid. Possible applications include on-line process monitoring, a hand-held density probe for battery charge state indication, and precise inventory control for such diverse fluids as uranium salt solutions in accountability storage and gasoline in service station storage tanks

  2. High-definition optical coherence tomography

    DEFF Research Database (Denmark)

    Boone, Marc; Norrenberg, Sarah; Jemec, Gregor

    2013-01-01

    to those described for reflectance confocal microscopy but with the advantages not only to visualize individual cells up to a depth of 570 μm but also in both slice and en face mode. An adapted algorithmic method for pattern analysis of common inflammatory skin diseases could be proposed. This new......High-definition optical coherence tomography (HD-OCT) is a non-invasive technique for morphological investigation of tissue with cellular resolution filling the imaging gap between reflectance confocal microscopy and conventional optical coherence tomography. The aim of this study is first...... dermatitis. Additional studies to test the sensitivity and specificity of the proposed algorithm for pattern analysis are essential. The other categories of Ackerman's pattern recognition need to be evaluated. This study provides a set of morphological features generated by HD-OCT imaging very similar...

  3. Improved image quality and diagnostic potential using ultra-high-resolution computed tomography of the lung with small scan FOV: A prospective study.

    Science.gov (United States)

    Zhu, Huiyuan; Zhang, Lian; Wang, Yali; Hamal, Preeti; You, Xiaofang; Mao, Haixia; Li, Fei; Sun, Xiwen

    2017-01-01

    The aim of this study was to assess whether CT imaging using an ultra-high-resolution CT (UHRCT) scan with a small scan field of view (FOV) provides higher image quality and helps to reduce the follow-up period compared with a conventional high-resolution CT (CHRCT) scan. We identified patients with at least one pulmonary nodule at our hospital from July 2015 to November 2015. CHRCT and UHRCT scans were conducted in all enrolled patients. Three experienced radiologists evaluated the image quality using a 5-point score and made diagnoses. The paired images were displayed side by side in a random manner and annotations of scan information were removed. The following parameters including image quality, diagnostic confidence of radiologists, follow-up recommendations and diagnostic accuracy were assessed. A total of 52 patients (62 nodules) were included in this study. UHRCT scan provides a better image quality regarding the margin of nodules and solid internal component compared to that of CHRCT (P images than of CHRCT images (Pimages (P 0.05). These findings suggest that the UHRCT prototype scanner provides a better image quality of subsolid nodules compared to CHRCT and contributes significantly to reduce the patients' follow-up period.

  4. Improved image quality and diagnostic potential using ultra-high-resolution computed tomography of the lung with small scan FOV: A prospective study.

    Directory of Open Access Journals (Sweden)

    Huiyuan Zhu

    Full Text Available The aim of this study was to assess whether CT imaging using an ultra-high-resolution CT (UHRCT scan with a small scan field of view (FOV provides higher image quality and helps to reduce the follow-up period compared with a conventional high-resolution CT (CHRCT scan. We identified patients with at least one pulmonary nodule at our hospital from July 2015 to November 2015. CHRCT and UHRCT scans were conducted in all enrolled patients. Three experienced radiologists evaluated the image quality using a 5-point score and made diagnoses. The paired images were displayed side by side in a random manner and annotations of scan information were removed. The following parameters including image quality, diagnostic confidence of radiologists, follow-up recommendations and diagnostic accuracy were assessed. A total of 52 patients (62 nodules were included in this study. UHRCT scan provides a better image quality regarding the margin of nodules and solid internal component compared to that of CHRCT (P 0.05. These findings suggest that the UHRCT prototype scanner provides a better image quality of subsolid nodules compared to CHRCT and contributes significantly to reduce the patients' follow-up period.

  5. Influence of Respiratory Gating, Image Filtering, and Animal Positioning on High-Resolution Electrocardiography-Gated Murine Cardiac Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chao Wu

    2015-01-01

    Full Text Available Cardiac parameters obtained from single-photon emission computed tomographic (SPECT images can be affected by respiratory motion, image filtering, and animal positioning. We investigated the influence of these factors on ultra-high-resolution murine myocardial perfusion SPECT. Five mice were injected with 99m technetium (99mTc-tetrofosmin, and each was scanned in supine and prone positions in a U-SPECT-II scanner with respiratory and electrocardiographic (ECG gating. ECG-gated SPECT images were created without applying respiratory motion correction or with two different respiratory motion correction strategies. The images were filtered with a range of three-dimensional gaussian kernels, after which end-diastolic volumes (EDVs, end-systolic volumes (ESVs, and left ventricular ejection fractions were calculated. No significant differences in the measured cardiac parameters were detected when any strategy to reduce or correct for respiratory motion was applied, whereas big differences (> 5% in EDV and ESV were found with regard to different positioning of animals. A linear relationship (p < .001 was found between the EDV or ESV and the kernel size of the gaussian filter. In short, respiratory gating did not significantly affect the cardiac parameters of mice obtained with ultra-high-resolution SPECT, whereas the position of the animals and the image filters should be the same in a comparative study with multiple scans to avoid systematic differences in measured cardiac parameters.

  6. High-resolution computed tomography evaluation of the bronchial lumen to vertebral body diameter and pulmonary artery to vertebral body diameter ratios in anesthetized ventilated normal cats.

    Science.gov (United States)

    Lee-Fowler, Tekla M; Cole, Robert C; Dillon, A Ray; Tillson, D Michael; Garbarino, Rachel; Barney, Sharron

    2017-10-01

    Objectives Bronchial lumen to pulmonary artery diameter (BA) ratio has been utilized to investigate pulmonary pathology on high-resolution CT images. Diseases affecting both the bronchi and pulmonary arteries render the BA ratio less useful. The purpose of the study was to establish bronchial lumen diameter to vertebral body diameter (BV) and pulmonary artery diameter to vertebral body diameter (AV) ratios in normal cats. Methods Using high-resolution CT images, 16 sets of measurements (sixth thoracic vertebral body [mid-body], each lobar bronchi and companion pulmonary artery diameter) were acquired from young adult female cats and 41 sets from pubertal female cats. Results Young adult and pubertal cat BV ratios were not statistically different from each other in any lung lobe. Significant differences between individual lung lobe BV ratios were noted on combined age group analysis. Caudal lung lobe AV ratios were significantly different between young adult and pubertal cats. All other lung lobe AV ratios were not significantly different. Caudal lung lobe AV ratios were significantly different from all other lung lobes but not from each other in both the young adult and pubertal cats. Conclusions and relevance BV ratio reference intervals determined for individual lung lobes could be applied to both young adult and pubertal cats. Separate AV ratios for individual lung lobes would be required for young adult and pubertal cats. These ratios should allow more accurate evaluation of cats with concurrent bronchial and pulmonary arterial disease.

  7. A tomografia computadorizada de alta resolução na avaliação da toxicidade pulmonar por amiodarona High-resolution computed tomography of amiodarone pulmonary toxicity

    Directory of Open Access Journals (Sweden)

    Daniela Peixoto Consídera

    2006-04-01

    Full Text Available OBJETIVO: Avaliar as principais alterações identificadas na tomografia computadorizada de alta resolução do tórax em pacientes com toxicidade pulmonar pela amiodarona. MATERIAIS E MÉTODOS: Foram avaliadas dez tomografias computadorizadas de alta resolução de tórax de pacientes com pneumonite pela amiodarona, seis desses pacientes do sexo masculino e quatro do sexo feminino, com idade média de 73,5 anos. RESULTADOS: Os achados tomográficos mais relevantes foram opacidades lineares ou reticulares em seis casos (60%, pequenos nódulos com densidade elevada em seis casos (60%, consolidações densas em três casos (30% e aumento da densidade do parênquima hepático em cinco de oito casos em que havia estudo tomográfico do abdome superior (62,5%. CONCLUSÃO: A tomografia computadorizada de alta resolução é um exame importante na avaliação de pacientes com toxicidade pulmonar pela amiodarona, devendo ser realizada sempre que houver suspeita deste diagnóstico. O achado de espessamento de septos interlobulares associado a lesões com aumento de densidade é altamente sugestivo deste diagnóstico.OBJECTIVE: To evaluate the main findings of chest high-resolution computed tomography in patients with amiodarone pulmonary toxicity. MATERIALS AND METHODS: Ten patients - six male and four female, average age of 73.5 years - with amiodarone-induced pneumonitis have undergone chest high-resolution computed tomography. RESULTS: The most relevant tomographic findings were linear or reticular opacities in six cases (60%, small high density nodules in six cases (60%, dense consolidations in three cases (30% and increased density in the hepatic parenchyma in five of eight cases in which there was a superior abdomen CT scan (62.5%. CONCLUSION: The high-resolution computed tomography is a valuable non-invasive test for evaluating patients with amiodarone pulmonary toxicity and should always be performed when one suspects of the presence of this

  8. Preliminary frequency-domain analysis for the reconstructed spatial resolution of muon tomography

    Science.gov (United States)

    Yu, B.; Zhao, Z.; Wang, X.; Wang, Y.; Wu, D.; Zeng, Z.; Zeng, M.; Yi, H.; Luo, Z.; Yue, X.; Cheng, J.

    2014-11-01

    Muon tomography is an advanced technology to non-destructively detect high atomic number materials. It exploits the multiple Coulomb scattering information of muon to reconstruct the scattering density image of the traversed object. Because of the statistics of muon scattering, the measurement error of system and the data incompleteness, the reconstruction is always accompanied with a certain level of interference, which will influence the reconstructed spatial resolution. While statistical noises can be reduced by extending the measuring time, system parameters determine the ultimate spatial resolution that one system can reach. In this paper, an effective frequency-domain model is proposed to analyze the reconstructed spatial resolution of muon tomography. The proposed method modifies the resolution analysis in conventional computed tomography (CT) to fit the different imaging mechanism in muon scattering tomography. The measured scattering information is described in frequency domain, then a relationship between the measurements and the original image is proposed in Fourier domain, which is named as "Muon Central Slice Theorem". Furthermore, a preliminary analytical expression of the ultimate reconstructed spatial is derived, and the simulations are performed for validation. While the method is able to predict the ultimate spatial resolution of a given system, it can also be utilized for the optimization of system design and construction.

  9. Preliminary frequency-domain analysis for the reconstructed spatial resolution of muon tomography

    International Nuclear Information System (INIS)

    Yu, B.; Zhao, Z.; Wang, X.; Wang, Y.; Wu, D.; Zeng, Z.; Zeng, M.; Yi, H.; Luo, Z.; Yue, X.; Cheng, J.

    2014-01-01

    Muon tomography is an advanced technology to non-destructively detect high atomic number materials. It exploits the multiple Coulomb scattering information of muon to reconstruct the scattering density image of the traversed object. Because of the statistics of muon scattering, the measurement error of system and the data incompleteness, the reconstruction is always accompanied with a certain level of interference, which will influence the reconstructed spatial resolution. While statistical noises can be reduced by extending the measuring time, system parameters determine the ultimate spatial resolution that one system can reach. In this paper, an effective frequency-domain model is proposed to analyze the reconstructed spatial resolution of muon tomography. The proposed method modifies the resolution analysis in conventional computed tomography (CT) to fit the different imaging mechanism in muon scattering tomography. The measured scattering information is described in frequency domain, then a relationship between the measurements and the original image is proposed in Fourier domain, which is named as M uon Central Slice Theorem . Furthermore, a preliminary analytical expression of the ultimate reconstructed spatial is derived, and the simulations are performed for validation. While the method is able to predict the ultimate spatial resolution of a given system, it can also be utilized for the optimization of system design and construction

  10. Novel injectable gellan gum hydrogel composites incorporating Zn- and Sr-enriched bioactive glass microparticles: High-resolution X-ray microcomputed tomography, antibacterial and in vitro testing.

    Science.gov (United States)

    Douglas, Timothy E L; Dziadek, Michal; Gorodzha, Svetlana; Lišková, Jana; Brackman, Gilles; Vanhoorne, Valérie; Vervaet, Chris; Balcaen, Lieve; Del Rosario Florez Garcia, Maria; Boccaccini, Aldo R; Weinhardt, Venera; Baumbach, Tilo; Vanhaecke, Frank; Coenye, Tom; Bačáková, Lucie; Surmeneva, Maria A; Surmenev, Roman A; Cholewa-Kowalska, Katarzyna; Skirtach, Andre G

    2018-06-01

    Mineralization of hydrogel biomaterials is desirable to improve their suitability as materials for bone regeneration. In this study, gellan gum (GG) hydrogels were formed by simple mixing of GG solution with bioactive glass microparticles of 45S5 composition, leading to hydrogel formation by ion release from the amorphous bioactive glass microparticles. This resulted in novel injectable, self-gelling composites of GG hydrogels containing 20% bioactive glass. Gelation occurred within 20 min. Composites containing the standard 45S5 bioactive glass preparation were markedly less stiff. X-ray microcomputed tomography proved to be a highly sensitive technique capable of detecting microparticles of diameter approximately 8 μm, that is, individual microparticles, and accurately visualizing the size distribution of bioactive glass microparticles and their aggregates, and their distribution in GG hydrogels. The widely used melt-derived 45S5 preparation served as a standard and was compared with a calcium-rich, sol-gel derived preparation (A2), as well as A2 enriched with zinc (A2Zn5) and strontium (A2Sr5). A2, A2Zn, and A2Sr bioactive glass particles were more homogeneously dispersed in GG hydrogels than 45S5. Composites containing all four bioactive glass preparations exhibited antibacterial activity against methicillin-resistant Staphylococcus aureus. Composites containing A2Zn5 and A2Sr5 bioactive glasses supported the adhesion and growth of osteoblast-like cells and were considerably more cytocompatible than 45S5. All composites underwent mineralization with calcium-deficient hydroxyapatite upon incubation in simulated body fluid. The extent of mineralization appeared to be greatest for composites containing A2Zn5 and 45S5. The results underline the importance of the choice of bioactive glass when preparing injectable, self-gelling composites. Copyright © 2018 John Wiley & Sons, Ltd.

  11. High resolution hadron calorimetry

    International Nuclear Information System (INIS)

    Wigmans, R.

    1987-01-01

    The components that contribute to the signal of a hadron calorimeter and the factors that affect its performance are discussed, concentrating on two aspects; energy resolution and signal linearity. Both are decisively dependent on the relative response to the electromagnetic and the non-electromagnetic shower components, the e/h signal ratio, which should be equal to 1.0 for optimal performance. The factors that determine the value of this ratio are examined. The calorimeter performance is crucially determined by its response to the abundantly present soft neutrons in the shower. The presence of a considerable fraction of hydrogen atoms in the active medium is essential for achieving the best possible results. Firstly, this allows one to tune e/h to the desired value by choosing the appropriate sampling fraction. And secondly, the efficient neutron detection via recoil protons in the readout medium itself reduces considerably the effect of fluctuations in binding energy losses at the nuclear level, which dominate the intrinsic energy resolution. Signal equalization, or compensation (e/h = 1.0) does not seem to be a property unique to 238 U, but can also be achieved with lead and probably even iron absorbers. 21 refs.; 19 figs

  12. High speed computer assisted tomography

    International Nuclear Information System (INIS)

    Maydan, D.; Shepp, L.A.

    1980-01-01

    X-ray generation and detection apparatus for use in a computer assisted tomography system which permits relatively high speed scanning. A large x-ray tube having a circular anode (3) surrounds the patient area. A movable electron gun (8) orbits adjacent to the anode. The anode directs into the patient area xrays which are delimited into a fan beam by a pair of collimating rings (21). After passing through the patient, x-rays are detected by an array (22) of movable detectors. Detector subarrays (23) are synchronously movable out of the x-ray plane to permit the passage of the fan beam

  13. High-resolution(18)F-fluorodeoxyglucose positron emission tomography and magnetic resonance imaging for pituitary adenoma detection in Cushing disease.

    Science.gov (United States)

    Chittiboina, Prashant; Montgomery, Blake K; Millo, Corina; Herscovitch, Peter; Lonser, Russell R

    2015-04-01

    OBJECT High-resolution PET (hrPET) performed using a high-resolution research tomograph is reported as having a resolution of 2 mm and could be used to detect corticotroph adenomas through uptake of(18)F-fluorodeoxyglucose ((18)F-FDG). To determine the sensitivity of this imaging modality, the authors compared(18)F-FDG hrPET and MRI detection of pituitary adenomas in Cushing disease (CD). METHODS Consecutive patients with CD who underwent preoperative(18)F-FDG hrPET and MRI (spin echo [SE] and spoiled gradient recalled [SPGR] sequences) were prospectively analyzed. Standardized uptake values (SUVs) were calculated from hrPET and were compared with MRI findings. Imaging findings were correlated to operative and histological findings. RESULTS Ten patients (7 females and 3 males) were included (mean age 30.8 ± 19.3 years; range 11-59 years). MRI revealed a pituitary adenoma in 4 patients (40% of patients) on SE and 7 patients (70%) on SPGR sequences.(18)F-FDG hrPET demonstrated increased(18)F-FDG uptake consistent with an adenoma in 4 patients (40%; adenoma size range 3-14 mm). Maximum SUV was significantly higher for(18)F-FDG hrPET-positive tumors (difference = 5.1, 95% CI 2.1-8.1; p = 0.004) than for(18)F-FDG hrPET-negative tumors.(18)F-FDG hrPET positivity was not associated with tumor volume (p = 0.2) or dural invasion (p = 0.5). Midnight and morning ACTH levels were associated with(18)F-FDG hrPET positivity (p = 0.01 and 0.04, respectively) and correlated with the maximum SUV (R = 0.9; p = 0.001) and average SUV (R = 0.8; p = 0.01). All(18)F-FDG hrPET-positive adenomas had a less than a 180% ACTH increase and(18)F-FDG hrPET-negative adenomas had a greater than 180% ACTH increase after CRH stimulation (p = 0.03). Three adenomas were detected on SPGR MRI sequences that were not detected by(18)F-FDG hrPET imaging. Two adenomas not detected on SE (but no adenomas not detected on SPGR) were detected on(18)F-FDG hrPET. CONCLUSIONS While(18)F-FDG hrPET imaging can

  14. Cenozoic volcanism in the Bohemian Massif in the context of P- and S-velocity high-resolution teleseismic tomography of the upper mantle

    Czech Academy of Sciences Publication Activity Database

    Plomerová, Jaroslava; Munzarová, Helena; Vecsey, Luděk; Kissling, E.; Achauer, U.; Babuška, Vladislav

    2016-01-01

    Roč. 17, č. 8 (2016), s. 3326-3349 ISSN 1525-2027 R&D Projects: GA ČR GAP210/12/2381; GA ČR GA205/01/1154; GA MŠk LM2010008; GA MŠk(CZ) LM2015079 Institutional support: RVO:67985530 Keywords : seismic tomography * upper mantle * body waves Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 3.201, year: 2016

  15. Ground-glass opacity in diffuse lung diseases: high-resolution computed tomography-pathology correlation; Opacidades em vidro fosco nas doencas pulmonares difusas: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Maria Lucia de Oliveira; Vianna, Alberto Domingues; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Disciplina de Radiologia; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Patologia]. E-mail: edmarchiori@zipmail.com.br

    2003-12-01

    Ground-glass opacity is a finding frequently seen in high-resolution computed tomography examinations of the chest and is characterized by hazy increased attenuation of lung, however without blurring of bronchial and vascular margins. Due to its un specificity, association with other radiological, clinical and pathological findings must be considered for an accurate diagnostic interpretation. In this paper were reviewed 62 computed tomography examinations of patients with diffuse pulmonary diseases of 14 different etiologies in which ground-glass opacity was the only or the most remarkable finding, and correlated this findings with pathology abnormalities seen on specimens obtained from biopsies or necropsies. In pneumocystosis, ground-glass opacities correlated histologically with alveolar occupation by a foaming material containing parasites, in bronchiole alveolar cell carcinoma with thickening of the alveolar septa and occupation of the lumen by mucus and tumoral cells, in paracoccidioidomycosis with thickening of the alveolar septa, areas of fibrosis and alveolar bronchopneumonia exudate, in sarcoidosis with fibrosis or clustering of granulomas and in idiopathic pulmonary fibrosis with alveolar septa thickening due to fibrosis. Alveolar occupation by blood was found in cases of leptospirosis, idiopathic hemo siderosis, metastatic kidney tumor and invasive aspergillosis whereas oily vacuole were seen in lipoid pneumonia, proteinaceous and lipo proteinaceous material in silico proteinosis and pulmonary alveolar proteinosis, and edematous fluid in cardiac failure. (author)

  16. High-resolution retinal swept source optical coherence tomography with an ultra-wideband Fourier-domain mode-locked laser at MHz A-scan rates.

    Science.gov (United States)

    Kolb, Jan Philip; Pfeiffer, Tom; Eibl, Matthias; Hakert, Hubertus; Huber, Robert

    2018-01-01

    We present a new 1060 nm Fourier domain mode locked laser (FDML laser) with a record 143 nm sweep bandwidth at 2∙ 417 kHz  =  834 kHz and 120 nm at 1.67 MHz, respectively. We show that not only the bandwidth alone, but also the shape of the spectrum is critical for the resulting axial resolution, because of the specific wavelength-dependent absorption of the vitreous. The theoretical limit of our setup lies at 5.9 µm axial resolution. In vivo MHz-OCT imaging of human retina is performed and the image quality is compared to the previous results acquired with 70 nm sweep range, as well as to existing spectral domain OCT data with 2.1 µm axial resolution from literature. We identify benefits of the higher resolution, for example the improved visualization of small blood vessels in the retina besides several others.

  17. Active and fossil mantle flows in the western Alpine region unravelled by seismic anisotropy analysis and high-resolution P wave tomography

    Science.gov (United States)

    Salimbeni, Simone; Malusà, Marco G.; Zhao, Liang; Guillot, Stéphane; Pondrelli, Silvia; Margheriti, Lucia; Paul, Anne; Solarino, Stefano; Aubert, Coralie; Dumont, Thierry; Schwartz, Stéphane; Wang, Qingchen; Xu, Xiaobing; Zheng, Tianyu; Zhu, Rixiang

    2018-04-01

    The anisotropy of seismic velocities in the mantle, when integrated with high-resolution tomographic models and geologic information, can be used to detect active mantle flows in complex plate boundary areas, providing new insights on the impact of mantle processes on the topography of mountain belts. Here we use a densely spaced array of temporary broadband seismic stations to analyze the seismic anisotropy pattern of the western Alpine region, at the boundary between the Alpine and Apenninic slabs. Our results are supportive of a polyphase development of anisotropic mantle fabrics, possibly starting from the Jurassic to present. Geophysical data presented in this work, and geologic evidence taken from the literature, indicate that: (i) fossil fabrics formed during Tethyan rifting may be still preserved within the Alpine and Apenninic slabs; (ii) mantle deformation during Apenninic slab rollback is not compensated by a complete toroidal flow around the northern tip of the retreating slab; (iii) the previously observed continuous trend of anisotropy fast axes near-parallel to the western Alpine arc is confirmed. We observe that this arc-parallel trend of fast axes is located in correspondence to a low velocity anomaly in the European upper mantle, beneath regions of the Western and Ligurian Alps showing the highest uplift rates. We propose that the progressive rollback of the Apenninic slab, in the absence of a counterclockwise toroidal flow at its northern tip, induced a suction effect at the scale of the supraslab mantle. The resulting mantle flow pattern was characterized by an asthenospheric counterflow at the rear of the unbroken Western Alps slab and around its southern tip, and by an asthenospheric upwelling, mirrored by low P wave velocities, that would have favored the topographic uplift of the Alpine belt from the Mont Blanc to the Mediterranean sea.

  18. The role of facial canal diameter in the pathogenesis and grade of Bell's palsy: a study by high resolution computed tomography.

    Science.gov (United States)

    Celik, Onur; Eskiizmir, Gorkem; Pabuscu, Yuksel; Ulkumen, Burak; Toker, Gokce Tanyeri

    The exact etiology of Bell's palsy still remains obscure. The only authenticated finding is inflammation and edema of the facial nerve leading to entrapment inside the facial canal. To identify if there is any relationship between the grade of Bell's palsy and diameter of the facial canal, and also to study any possible anatomic predisposition of facial canal for Bell's palsy including parts which have not been studied before. Medical records and temporal computed tomography scans of 34 patients with Bell's palsy were utilized in this retrospective clinical study. Diameters of both facial canals (affected and unaffected) of each patient were measured at labyrinthine segment, geniculate ganglion, tympanic segment, second genu, mastoid segment and stylomastoid foramen. The House-Brackmann (HB) scale of each patient at presentation and 3 months after the treatment was evaluated from their medical records. The paired samples t-test and Wilcoxon signed-rank test were used for comparison of width between the affected side and unaffected side. The Wilcoxon signed-rank test was also used for evaluation of relationship between the diameter of facial canal and the grade of the Bell's palsy. Significant differences were established at a level of p=0.05 (IBM SPSS Statistics for Windows, Version 21.0.; Armonk, NY, IBM Corp). Thirty-four patients - 16 females, 18 males; mean age±Standard Deviation, 40.3±21.3 - with Bell's palsy were included in the study. According to the HB facial nerve grading system; 8 patients were grade V, 6 were grade IV, 11 were grade III, 8 were grade II and 1 patient was grade I. The mean width at the labyrinthine segment of the facial canal in the affected temporal bone was significantly smaller than the equivalent in the unaffected temporal bone (p=0.00). There was no significant difference between the affected and unaffected temporal bones at the geniculate ganglion (p=0.87), tympanic segment (p=0.66), second genu (p=0.62), mastoid segment (p=0

  19. Time resolution in scintillator based detectors for positron emission tomography

    International Nuclear Information System (INIS)

    Gundacker, S.

    2014-01-01

    In the domain of medical photon detectors L(Y)SO scintillators are used for positron emission tomography (PET). The interest for time of flight (TOF) in PET is increasing since measurements have shown that new crystals like L(Y)SO coupled to state of the art photodetectors, e.g. silicon photomultipliers (SiPM), can reach coincidence time resolutions (CTRs) of far below 500ps FWHM. To achieve these goals it is important to study the processe in the whole detection chain, i.e. the high energy particle or gamma interaction in the crystal, the scintillation process itself, the light propagation in the crystal with the light transfer to the photodetector, and the electronic readout. In this thesis time resolution measurements for a PET like system are performed in a coincidence setup utilizing the ultra fast amplifier discriminator NINO. We found that the time-over-threshold energy information provided by NINO shows a degradation in energy resolution for higher SiPM bias voltages. This is a consequence of the increasing dark count rate (DCR) of the SiPM with higher bias voltages together with the exponential decay of the signal. To overcome this problem and to operate the SiPM at its optimum voltage in terms of timing we developed a new electronic board that employs NINO only as a low noise leading edge discriminator together with an analog amplifier which delivers the energy information. With this new electronic board we indeed improved the measured CTR by about 15%. To study the limits of time resolution in more depth we measured the CTR with 2x2x3mm3 LSO:Ce codoped 0.4%Ca crystals coupled to commercially available SiPMs (Hamamatsu S10931-50P MPPC) and achieved a CTR of 108±5ps FWHM at an energy of 511keV. We determined the influence of the data acquisition system and the electronics on the CTR to be 27±2ps FWHM and thus negligible. To quantitatively understand the measured values, we developed a Monte Carlo simulation tool in MATLAB that incorporates the timing

  20. High speed laser tomography system

    Science.gov (United States)

    Samsonov, D.; Elsaesser, A.; Edwards, A.; Thomas, H. M.; Morfill, G. E.

    2008-03-01

    A high speed laser tomography system was developed capable of acquiring three-dimensional (3D) images of optically thin clouds of moving micron-sized particles. It operates by parallel-shifting an illuminating laser sheet with a pair of galvanometer-driven mirrors and synchronously recording two-dimensional (2D) images of thin slices of the imaged volume. The maximum scanning speed achieved was 120000slices/s, sequences of 24 volume scans (up to 256 slices each) have been obtained. The 2D slices were stacked to form 3D images of the volume, then the positions of the particles were identified and followed in the consecutive scans. The system was used to image a complex plasma with particles moving at speeds up to cm/s.

  1. Diffusible iodine-based contrast-enhanced computed tomography (diceCT): an emerging tool for rapid, high-resolution, 3-D imaging of metazoan soft tissues.

    Science.gov (United States)

    Gignac, Paul M; Kley, Nathan J; Clarke, Julia A; Colbert, Matthew W; Morhardt, Ashley C; Cerio, Donald; Cost, Ian N; Cox, Philip G; Daza, Juan D; Early, Catherine M; Echols, M Scott; Henkelman, R Mark; Herdina, A Nele; Holliday, Casey M; Li, Zhiheng; Mahlow, Kristin; Merchant, Samer; Müller, Johannes; Orsbon, Courtney P; Paluh, Daniel J; Thies, Monte L; Tsai, Henry P; Witmer, Lawrence M

    2016-06-01

    Morphologists have historically had to rely on destructive procedures to visualize the three-dimensional (3-D) anatomy of animals. More recently, however, non-destructive techniques have come to the forefront. These include X-ray computed tomography (CT), which has been used most commonly to examine the mineralized, hard-tissue anatomy of living and fossil metazoans. One relatively new and potentially transformative aspect of current CT-based research is the use of chemical agents to render visible, and differentiate between, soft-tissue structures in X-ray images. Specifically, iodine has emerged as one of the most widely used of these contrast agents among animal morphologists due to its ease of handling, cost effectiveness, and differential affinities for major types of soft tissues. The rapid adoption of iodine-based contrast agents has resulted in a proliferation of distinct specimen preparations and scanning parameter choices, as well as an increasing variety of imaging hardware and software preferences. Here we provide a critical review of the recent contributions to iodine-based, contrast-enhanced CT research to enable researchers just beginning to employ contrast enhancement to make sense of this complex new landscape of methodologies. We provide a detailed summary of recent case studies, assess factors that govern success at each step of the specimen storage, preparation, and imaging processes, and make recommendations for standardizing both techniques and reporting practices. Finally, we discuss potential cutting-edge applications of diffusible iodine-based contrast-enhanced computed tomography (diceCT) and the issues that must still be overcome to facilitate the broader adoption of diceCT going forward. © 2016 The Authors. Journal of Anatomy published by John Wiley & Sons Ltd on behalf of Anatomical Society.

  2. High-resolution CT of lesions of the optic nerve

    International Nuclear Information System (INIS)

    Peyster, R.G.; Hoover, E.D.; Hershey, B.L.; Haskin, M.E.

    1983-01-01

    The optic nerves are well demonstrated by high-resolution computed tomography. Involvement of the optic nerve by optic gliomas and optic nerve sheath meningiomas is well known. However, nonneoplastic processes such as increased intracranial pressure, optic neuritis, Grave ophthalmopathy, and orbital pseudotumor may also alter the appearance of the optic nerve/sheath on computed tomography. Certain clinical and computed tomographic features permit distinction of these nonneoplastic tumefactions from tumors

  3. Fibrose maciça progressiva em trabalhadores expostos à sílica: achados na tomografia computadorizada de alta resolução Progressive massive fibrosis in silica-exposed workers: high-resolution computed tomography findings

    Directory of Open Access Journals (Sweden)

    Ângela Santos Ferreira

    2006-12-01

    Full Text Available OBJETIVO: Avaliar as características radiológicas das massas conglomeradas pela tomografia computadorizada de alta resolução de tórax. MÉTODOS: Foram selecionados 75 pacientes silicóticos, a maioria jateadores de areia, portadores de fibrose maciça progressiva, atendidos no Hospital Universitário Antônio Pedro entre 1986 e 2004. Os pacientes foram submetidos a avaliação clínica, radiografia simples de tórax e tomografia computadorizada de alta resolução. RESULTADOS: Mais da metade dos pacientes com silicose complicada mostrou na radiografia de tórax grandes opacidades dos tipos B e C, denotando a gravidade da doença nesses pacientes. Dos 75 casos, apenas um apresentou massa unilateral simulando câncer de pulmão. Quarenta e quatro pacientes realizaram tomografia computadorizada de alta resolução do tórax. As massas predominaram nos terços superiores e posteriores (88,6%. Broncograma aéreo e calcificações no interior das massas foram observados em 70,4% e 63,8% dos casos, respectivamente. História de tuberculose foi relatada em 52% dos pacientes estudados. CONCLUSÃO: Na grande maioria dos casos as massas eram bilaterais, predominando nas regiões póstero-superiores dos pulmões, com broncogramas aéreos e calcificações de permeio. Associação com calcificações linfonodais foi um achado freqüente. A exposição a elevadas concentrações de poeira e a tuberculose foram consideradas fatores de risco para o desenvolvimento da fibrose maciça progressiva.OBJECTIVE: To evaluate the radiological characteristics of conglomerate masses using high-resolution computed tomography of the chest. METHODS: From among the patients treated between 1986 and 2004 at the Antonio Pedro University Hospital, 75 patients with silicosis and massive fibrosis, most working in the field of sandblasting, were selected for study. These patients were submitted to a clinical evaluation, chest X-ray and high-resolution computed tomography of

  4. High resolution metric imaging payload

    Science.gov (United States)

    Delclaud, Y.

    2017-11-01

    Alcatel Space Industries has become Europe's leader in the field of high and very high resolution optical payloads, in the frame work of earth observation system able to provide military government with metric images from space. This leadership allowed ALCATEL to propose for the export market, within a French collaboration frame, a complete space based system for metric observation.

  5. Using x-ray computed tomography in hydrology: Systems, resolutions, and limitations

    DEFF Research Database (Denmark)

    Wildenschild, Dorthe; Hopmans, J.W.; Vaz, C.M.P.

    2002-01-01

    media, obtained with different scanning systems and sample sizes, to illustrate advantages and limitations of these various systems, including topics of spatial resolution and contrast. In addition, we present examples of our most recent three-dimensional high-resolution images, for which......A combination of advances in experimental techniques and mathematical analysis has made it possible to characterize phase distribution and pore geometry in porous media using non-destructive X-ray computed tomography (CT). We present qualitative and quantitative CT results for partially saturated...

  6. Berkeley High-Resolution Ball

    International Nuclear Information System (INIS)

    Diamond, R.M.

    1984-10-01

    Criteria for a high-resolution γ-ray system are discussed. Desirable properties are high resolution, good response function, and moderate solid angle so as to achieve not only double- but triple-coincidences with good statistics. The Berkeley High-Resolution Ball involved the first use of bismuth germanate (BGO) for anti-Compton shield for Ge detectors. The resulting compact shield permitted rather close packing of 21 detectors around a target. In addition, a small central BGO ball gives the total γ-ray energy and multiplicity, as well as the angular pattern of the γ rays. The 21-detector array is nearly complete, and the central ball has been designed, but not yet constructed. First results taken with 9 detector modules are shown for the nucleus 156 Er. The complex decay scheme indicates a transition from collective rotation (prolate shape) to single- particle states (possibly oblate) near spin 30 h, and has other interesting features

  7. Insights into the mechanics of en-échelon sigmoidal vein formation using ultra-high resolution photogrammetry and computed tomography

    Science.gov (United States)

    Thiele, Samuel T.; Micklethwaite, Steven; Bourke, Paul; Verrall, Michael; Kovesi, Peter

    2015-08-01

    Two novel techniques, photo based reconstruction (photogrammetry) and computed tomography (CT), are used to investigate the formation of an exceptional array of sigmoidal veins in a hand sample from Cape Liptrap, Southern Victoria, and to provide constraint on models for their development. The accuracies of the photogrammetric models were tested by comparison with a laser scan generated three dimensional (3D) model. The photogrammetric model was found to be accurate to at least 0.25 mm and substantially more detailed than the laser scan. A methodology was developed by which 3D structural measurements could be extracted from the photogrammetric model. This was augmented with the CT model which, through its capacity to elucidate internal structure, was used to constrain the geometry and linkage of structures within the rock volume. The photogrammetric and CT data were then combined with detailed photomicrographs to evaluate the evolution of the sigmoidal veins in the sample. The angle between the sigmoidal vein margins and an inferred shear zone, as well as the orientations of the crystal fibres, were found to imply a rotation of >27°. However coeval pressure solution seams and older veinlets in the rock bridges between the veins were only found to have rotated by ∼10°, an observation not easily explained using existing models for sigmoidal vein formation. A new model is proposed in which a significant component of sigmoidal vein geometry is due to localised dilation caused by slip on the pressure solution seams. The process involves strain partitioning onto pressure solution seams, which leads to exaggeration of sigmoidal vein geometries. If not accounted for, the apparent vein rotation due to slip partitioning introduces errors into calculations of simple shear and volume strain based on sigmoidal arrays of this type. Furthermore, the CT data demonstrated that in 3D the veins are continuous and channel-like, implying a far higher degree of connectivity and

  8. Research for obtaining a detection system with high spatial and temporal resolution for a tomograph with positron emission (PET-Tomography)

    International Nuclear Information System (INIS)

    Cruceru, Ilie; Bartos, Daniel; Stanescu, Daniela

    2002-01-01

    This report describes a new type of detector for a tomograph system with positron emission. The detector has a new design with detection characteristics better than other detectors used currently in tomographic systems. We have in view the detectors like NaI(Tl), CsI(Tl), BGO and others. The new detector is based on discharge in gases and the interaction of gamma radiation - generated in the annihilation processes of positrons - with the mixture of gases within detector. The main novelty is the structure of electrodes with central readout microstrip plate. This structure is composed from two identical chambers. Each of these chambers have two glass resistive electrodes and one metallic electrode (cathode). One of the glass electrodes is separated from the metallic electrode while the other one is in contact with the central readout microstrip plate. In this way to gaps of 0.3 mm are generated. The gas mixture flows between these gaps. The electric charges generated in this gas are collected on the strips under the influence of the electric field applied between cathode and the anode of the detector.The arrangement of electrodes is shown. The structure of electrodes is mounted into a metallic box of special construction which allows the gas to flow through the detector and collects the electric charges generated in the detector. At present the detector is in the stage of a laboratory model and the tests carried out led to the following detection parameters: detection efficiency, 95%; spatial resolution, 3 mm; time resolution, 82 ps. The measurements were performed in coincidence using two similar detectors and the source of positrons was located between detectors. In the next stage of research will be defined the final constructive solution of the experimental model, built and tested for this positron source. The mixture of gases used for tests contained 85%C 2 H 2 F 4 + 10%SF 6 + 5%C 4 H 10 (isobutane). (authors)

  9. 99mTc-IgG-Lung Scintigraphy in the Assessment of Pulmonary Involvement in Interstitial Lung Disease and Its Comparison With Pulmonary Function Tests and High-Resolution Computed Tomography: A Preliminary Study

    International Nuclear Information System (INIS)

    Bahtouee, Mehrzad; Saberifard, Jamshid; Javadi, Hamid; Nabipour, Iraj; Malakizadeh, Hasan; Monavvarsadegh, Gholamhossein; Ilkhani Pak, Hoda; Sadeghi, Azadeh; Assadi, Majid

    2015-01-01

    The discrimination of inactive inflammatory processes from the active form of the disease is of great importance in the management of interstitial lung disease (ILD). The aim of this study was to determine the efficacy of 99mTc-IgG scan for the detection of severity of disease compared to high-resolution computed tomography (HRCT) and pulmonary function test (PFT). Eight known cases of ILD including four cases of Mustard gas (MG) intoxication and four patients with ILD of unknown cause were included in this study. A population of six patients without lung disease was considered as the control group. The patients underwent PFT and high-resolution computed tomography, followed by 99mTc-IgG scan. They were followed up for one year. 99mTc-IgG scan assessment of IgG uptake was accomplished both qualitatively (subjectively) and semiquantitatively. All eight ILD patients demonstrated a strong increase in 99mTc-IgG uptake in the lungs, compared to the control patients. The 99mTc-IgG scan scores were higher in the patient group (0.64[95% confidence interval(CI)=0.61-0.69])) than the control group (0.35 (0.35[95% CI=0.28-0.40]), (P<0.05)). In patients, a statistically significant positive correlation was detected between 99mTc-IgG scan and HRCT scores (Spearman’s correlation coefficient = 0.92, P < 0.008). The 99mTc-Human Immunoglobulin (HIG) scores were not significantly correlated with PFT findings (including FVC, FEV1, FEV1/FVC), O 2 saturation and age (P values > 0.05). There were no significant correlations between 99mTc-IgG score and HRCT patterns including ground glass opacity, reticular fibrosis and honeycombing (P value > 0.05). The present results confirmed that 99mTc-IgG scan could be applied to detect the severity of pulmonary involvement, which was well correlated with HRCT findings. This data also showed that the 99mTc-IgG scan might be used as a complement to HRCT in the functional evaluation of the clinical status in ILD; however, further studies are

  10. High resolution CT of temporal bone trauma

    International Nuclear Information System (INIS)

    Youn, Eun Kyung

    1986-01-01

    Radiographic studies of the temporal bone following head trauma are indicated when there is cerebrospinal fluid otorrhea or rhinorrhoea, hearing loss, or facial nerve paralysis. Plain radiography displays only 17-30% of temporal bone fractures and pluridirectional tomography is both difficult to perform, particularly in the acutely ill patient, and less satisfactory for the demonstration of fine fractures. Consequently, high resolution CT is the imaging method of choice for the investigation of suspected temporal bone trauma and allows special resolution of fine bony detail comparable to that attainable by conventional tomography. Eight cases of temporal bone trauma examined at Korea General Hospital April 1985 through May 1986. The results were as follows: Seven patients (87%) suffered longitudinal fractures. In 6 patients who had purely conductive hearing loss, CT revealed various ossicular chain abnormality. In one patient who had neuro sensory hearing loss, CT demonstrated intract ossicular with a fracture nearing lateral wall of the lateral semicircular canal. In one patient who had mixed hearing loss, CT showed complex fracture.

  11. Requirements on high resolution detectors

    Energy Technology Data Exchange (ETDEWEB)

    Koch, A. [European Synchrotron Radiation Facility, Grenoble (France)

    1997-02-01

    For a number of microtomography applications X-ray detectors with a spatial resolution of 1 {mu}m are required. This high spatial resolution will influence and degrade other parameters of secondary importance like detective quantum efficiency (DQE), dynamic range, linearity and frame rate. This note summarizes the most important arguments, for and against those detector systems which could be considered. This article discusses the mutual dependencies between the various figures which characterize a detector, and tries to give some ideas on how to proceed in order to improve present technology.

  12. Interior tomography in microscopic CT with image reconstruction constrained by full field of view scan at low spatial resolution

    Science.gov (United States)

    Luo, Shouhua; Shen, Tao; Sun, Yi; Li, Jing; Li, Guang; Tang, Xiangyang

    2018-04-01

    In high resolution (microscopic) CT applications, the scan field of view should cover the entire specimen or sample to allow complete data acquisition and image reconstruction. However, truncation may occur in projection data and results in artifacts in reconstructed images. In this study, we propose a low resolution image constrained reconstruction algorithm (LRICR) for interior tomography in microscopic CT at high resolution. In general, the multi-resolution acquisition based methods can be employed to solve the data truncation problem if the project data acquired at low resolution are utilized to fill up the truncated projection data acquired at high resolution. However, most existing methods place quite strict restrictions on the data acquisition geometry, which greatly limits their utility in practice. In the proposed LRICR algorithm, full and partial data acquisition (scan) at low and high resolutions, respectively, are carried out. Using the image reconstructed from sparse projection data acquired at low resolution as the prior, a microscopic image at high resolution is reconstructed from the truncated projection data acquired at high resolution. Two synthesized digital phantoms, a raw bamboo culm and a specimen of mouse femur, were utilized to evaluate and verify performance of the proposed LRICR algorithm. Compared with the conventional TV minimization based algorithm and the multi-resolution scout-reconstruction algorithm, the proposed LRICR algorithm shows significant improvement in reduction of the artifacts caused by data truncation, providing a practical solution for high quality and reliable interior tomography in microscopic CT applications. The proposed LRICR algorithm outperforms the multi-resolution scout-reconstruction method and the TV minimization based reconstruction for interior tomography in microscopic CT.

  13. High resolution optical DNA mapping

    Science.gov (United States)

    Baday, Murat

    Many types of diseases including cancer and autism are associated with copy-number variations in the genome. Most of these variations could not be identified with existing sequencing and optical DNA mapping methods. We have developed Multi-color Super-resolution technique, with potential for high throughput and low cost, which can allow us to recognize more of these variations. Our technique has made 10--fold improvement in the resolution of optical DNA mapping. Using a 180 kb BAC clone as a model system, we resolved dense patterns from 108 fluorescent labels of two different colors representing two different sequence-motifs. Overall, a detailed DNA map with 100 bp resolution was achieved, which has the potential to reveal detailed information about genetic variance and to facilitate medical diagnosis of genetic disease.

  14. High angular resolution at LBT

    Science.gov (United States)

    Conrad, A.; Arcidiacono, C.; Bertero, M.; Boccacci, P.; Davies, A. G.; Defrere, D.; de Kleer, K.; De Pater, I.; Hinz, P.; Hofmann, K. H.; La Camera, A.; Leisenring, J.; Kürster, M.; Rathbun, J. A.; Schertl, D.; Skemer, A.; Skrutskie, M.; Spencer, J. R.; Veillet, C.; Weigelt, G.; Woodward, C. E.

    2015-12-01

    High angular resolution from ground-based observatories stands as a key technology for advancing planetary science. In the window between the angular resolution achievable with 8-10 meter class telescopes, and the 23-to-40 meter giants of the future, LBT provides a glimpse of what the next generation of instruments providing higher angular resolution will provide. We present first ever resolved images of an Io eruption site taken from the ground, images of Io's Loki Patera taken with Fizeau imaging at the 22.8 meter LBT [Conrad, et al., AJ, 2015]. We will also present preliminary analysis of two data sets acquired during the 2015 opposition: L-band fringes at Kurdalagon and an occultation of Loki and Pele by Europa (see figure). The light curves from this occultation will yield an order of magnitude improvement in spatial resolution along the path of ingress and egress. We will conclude by providing an overview of the overall benefit of recent and future advances in angular resolution for planetary science.

  15. A high-resolution computed tomography-based scoring system to differentiate the most infectious active pulmonary tuberculosis from community-acquired pneumonia in elderly and non-elderly patients

    International Nuclear Information System (INIS)

    Yeh, Jun-Jun; Chen, Solomon Chih-Cheng; Chen, Cheng-Ren; Yeh, Ting-Chun; Lin, Hsin-Kai; Hong, Jia-Bin; Wu, Bing-Tsang; Wu, Ming-Ting

    2014-01-01

    The objective of this study was to use high-resolution computed tomography (HRCT) imaging to predict the presence of smear-positive active pulmonary tuberculosis (PTB) in elderly (at least 65 years of age) and non-elderly patients (18-65 years of age). Patients with active pulmonary infections seen from November 2010 through December 2011 received HRCT chest imaging, sputum smears for acid-fast bacilli and sputum cultures for Mycobacterium tuberculosis. Smear-positive PTB was defined as at least one positive sputum smear and a positive culture for M. tuberculosis. Multivariate logistic regression analyses were performed to determine the HRCT predictors of smear-positive active PTB, and a prediction score was developed on the basis of receiver operating characteristic curve analysis. Of 1,255 patients included, 139 were diagnosed with smear-positive active PTB. According to ROC curve analysis, the sensitivity, specificity, positive predictive value, negative predictive value, false positive rates and false negative rates were 98.6 %, 95.8 %, 78.5 %, 99.8 %, 4.2 % and 1.4 %, respectively, for diagnosing smear-positive active PTB in elderly patients, and 100.0 %, 96.9 %, 76.5 %, 100.0 %, 3.1 % and 0.0 %, respectively, for non-elderly patients. HRCT can assist in the early diagnosis of the most infectious active PTB, thereby preventing transmission and minimizing unnecessary immediate respiratory isolation. (orig.)

  16. The correlation of symptoms, pulmonary function tests and exercise testing with high-resolution computed tomography in patients with idiopathic interstitial pneumonia in a tertiary care hospital in South India.

    Science.gov (United States)

    Isaac, Barney Thomas Jesudason; Thangakunam, Balamugesh; Cherian, Rekha A; Christopher, Devasahayam Jesudas

    2015-01-01

    For the follow-up of patients with idiopathic interstitial pneumonias (IIP), it is unclear which parameters of pulmonary function tests (PFT) and exercise testing would correlate best with high-resolution computed tomography (HRCT).. To find out the correlation of symptom scores, PFTs and exercise testing with HRCT scoring in patients diagnosed as idiopathic interstitial pneumonia. Cross-sectional study done in pulmonary medicine outpatients department of a tertiary care hospital in South India. Consecutive patients who were diagnosed as IIP by a standard algorithm were included into the study. Cough and dyspnea were graded for severity and duration. Pulmonary function tests and exercise testing parameters were noted. HRCT was scored based on an alveolar score, an interstitial score and a total score. The HRCT was correlated with each of the clinical and physiologic parameters. Pearson's/Spearman's correlation coefficient was used for the correlation of symptoms and parameters of ABG, PFT and 6MWT with the HRCT scores. A total of 94 patients were included in the study. Cough and dyspnea severity (r = 0.336 and 0.299), FVC (r = -0.48), TLC (r = -0.439) and DLCO and distance saturation product (DSP) (r = -0.368) and lowest saturation (r = -0.324) had significant correlation with total HRCT score. Among these, DLCO, particularly DLCO corrected % of predicted, correlated best with HRCT score (r = -0.721).. Symptoms, PFT and exercise testing had good correlation with HRCT. DLCO corrected % of predicted correlated best with HRCT.

  17. A high-resolution computed tomography-based scoring system to differentiate the most infectious active pulmonary tuberculosis from community-acquired pneumonia in elderly and non-elderly patients

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, Jun-Jun [Ditmanson Medical Foundation Chia-Yi Christian Hospital, Section of Thoracic Imaging, Department of Chest Medicine and Family Medicine, Chiayi City (China); Chia Nan University of Pharmacy and Science, Tainan (China); Meiho University, Pingtung (China); Pingtung Christian Hospital, Pingtung (China); Chen, Solomon Chih-Cheng; Chen, Cheng-Ren [Ditmanson Medical Foundation Chia-Yi Christian Hospital, Department of Medical Research, Chiayi City (China); Yeh, Ting-Chun; Lin, Hsin-Kai; Hong, Jia-Bin; Wu, Bing-Tsang [Ditmanson Medical Foundation Chia-Yi Christian Hospital, Department of Family Medicine, Chiayi City (China); Wu, Ming-Ting [Department of Radiology, Kaohsiung Veterans General Hospital, Section of Thoracic and Circulation Imaging, Kaohsiung (China); School of Medicine, National Yang Ming University, Faculty of Medicine, Taipei (China)

    2014-10-15

    The objective of this study was to use high-resolution computed tomography (HRCT) imaging to predict the presence of smear-positive active pulmonary tuberculosis (PTB) in elderly (at least 65 years of age) and non-elderly patients (18-65 years of age). Patients with active pulmonary infections seen from November 2010 through December 2011 received HRCT chest imaging, sputum smears for acid-fast bacilli and sputum cultures for Mycobacterium tuberculosis. Smear-positive PTB was defined as at least one positive sputum smear and a positive culture for M. tuberculosis. Multivariate logistic regression analyses were performed to determine the HRCT predictors of smear-positive active PTB, and a prediction score was developed on the basis of receiver operating characteristic curve analysis. Of 1,255 patients included, 139 were diagnosed with smear-positive active PTB. According to ROC curve analysis, the sensitivity, specificity, positive predictive value, negative predictive value, false positive rates and false negative rates were 98.6 %, 95.8 %, 78.5 %, 99.8 %, 4.2 % and 1.4 %, respectively, for diagnosing smear-positive active PTB in elderly patients, and 100.0 %, 96.9 %, 76.5 %, 100.0 %, 3.1 % and 0.0 %, respectively, for non-elderly patients. HRCT can assist in the early diagnosis of the most infectious active PTB, thereby preventing transmission and minimizing unnecessary immediate respiratory isolation. (orig.)

  18. Relationships (I) of International Classification of High-resolution Computed Tomography for Occupational and Environmental Respiratory Diseases with the ILO International Classification of Radiographs of Pneumoconioses for parenchymal abnormalities.

    Science.gov (United States)

    Tamura, Taro; Suganuma, Narufumi; Hering, Kurt G; Vehmas, Tapio; Itoh, Harumi; Akira, Masanori; Takashima, Yoshihiro; Hirano, Harukazu; Kusaka, Yukinori

    2015-01-01

    The International Classification of High-resolution Computed Tomography (HRCT) for Occupational and Environmental Respiratory Diseases (ICOERD) has been developed for the screening, diagnosis, and epidemiological reporting of respiratory diseases caused by occupational hazards. This study aimed to establish a correlation between readings of HRCT (according to the ICOERD) and those of chest radiography (CXR) pneumoconiotic parenchymal opacities (according to the International Labor Organization Classification/International Classification of Radiographs of Pneumoconioses [ILO/ICRP]). Forty-six patients with and 28 controls without mineral dust exposure underwent posterior-anterior CXR and HRCT. We recorded all subjects' exposure and smoking history. Experts independently read CXRs (using ILO/ICRP). Experts independently assessed HRCT using the ICOERD parenchymal abnormalities grades for well-defined rounded opacities (RO), linear and/or irregular opacities (IR), and emphysema (EM). The correlation between the ICOERD summed grades and ILO/ICRP profusions was evaluated using Spearman's rank-order correlation. Twenty-three patients had small opacities on CXR. HRCT showed that 21 patients had RO; 20 patients, IR opacities; and 23 patients, EM. The correlation between ILO/ICRP profusions and the ICOERD grades was 0.844 for rounded opacities (p<0.01). ICOERD readings from HRCT scans correlated well with previously validated ILO/ICRP criteria. The ICOERD adequately detects pneumoconiotic micronodules and can be used for the interpretation of pneumoconiosis.

  19. Pleuro-pulmonary abnormalities in patients with systemic lupus erythematosus assessment with high resolution computed tomography, chest radiography and pulmonary function tests

    Energy Technology Data Exchange (ETDEWEB)

    Sant, S.M.; Doran, M.; Fenelon, H.M.; Breatnach, E.S. [University of Michigan (United States)

    1998-04-01

    The objective has to assess the nature of pleuro-pulmonary abnormalities, with particular reference to interstitial lung disease (ILD), in patients with systemic lupus erythematosus (SLE) In conclusion, HRCT is more sensitive than PFTs or CXR in the evaluation of pleuro-pulmonary disease in SLE. We report an unusually high prevalence of HRCT appearances suggestive of ILD in patients with SLE. subclinical lung disease is common in patients with SLE. (author)

  20. Pleuro-pulmonary abnormalities in patients with systemic lupus erythematosus assessment with high resolution computed tomography, chest radiography and pulmonary function tests

    International Nuclear Information System (INIS)

    Sant, S.M.; Doran, M.; Fenelon, H.M.; Breatnach, E.S.

    1998-01-01

    The objective has to assess the nature of pleuro-pulmonary abnormalities, with particular reference to interstitial lung disease (ILD), in patients with systemic lupus erythematosus (SLE) In conclusion, HRCT is more sensitive than PFTs or CXR in the evaluation of pleuro-pulmonary disease in SLE. We report an unusually high prevalence of HRCT appearances suggestive of ILD in patients with SLE. subclinical lung disease is common in patients with SLE. (author)

  1. High resolution multiplexed functional imaging in live embryos (Conference Presentation)

    Science.gov (United States)

    Xu, Dongli; Zhou, Weibin; Peng, Leilei

    2017-02-01

    Fourier multiplexed fluorescence lifetime imaging (FmFLIM) scanning laser optical tomography (FmFLIM-SLOT) combines FmFLIM and Scanning laser optical tomography (SLOT) to perform multiplexed 3D FLIM imaging of live embryos. The system had demonstrate multiplexed functional imaging of zebrafish embryos genetically express Foster Resonant Energy Transfer (FRET) sensors. However, previous system has a 20 micron resolution because the focused Gaussian beam diverges quickly from the focused plane, makes it difficult to achieve high resolution imaging over a long projection depth. Here, we present a high-resolution FmFLIM-SLOT system with achromatic Bessel beam, which achieves 3 micron resolution in 3D deep tissue imaging. In Bessel-FmFLIM-SLOT, multiple laser excitation lines are firstly intensity modulated by a Michelson interferometer with a spinning polygon mirror optical delay line, which enables Fourier multiplexed multi-channel lifetime measurements. Then, a spatial light modulator and a prism are used to transform the modulated Gaussian laser beam to an achromatic Bessel beam. The achromatic Bessel beam scans across the whole specimen with equal angular intervals as sample rotated. After tomography reconstruction and the frequency domain lifetime analysis method, both the 3D intensity and lifetime image of multiple excitation-emission can be obtained. Using Bessel-FmFLIM-SLOT system, we performed cellular-resolution FLIM tomography imaging of live zebrafish embryo. Genetically expressed FRET sensors in these embryo will allow non-invasive observation of multiple biochemical processes in vivo.

  2. High resolution techniques using scanning proton microprobe (SPM)

    International Nuclear Information System (INIS)

    Cholewa, M.; Saint, A.; Prawer, S.; Laird, J.S.; Legge, G.J.F.; Bardos, R.A.; Moorhead, G.F.; Taylor, G.N.; Stuart, S.A.; Howard, J.

    1994-01-01

    The very high resolution (down to 50 nm) achieved with low beam currents (fA) in a scanning ion microprobe have lead to many nondestructive techniques of microanalysis. This paper discusses recent developments and applications in the use of 3-D STIM (scanning transmission ion microscopy) Tomography, channeling STIM and IBIC (ion beam induced charge). (orig.)

  3. Pattern of interstitial lung disease detected by high resolution ...

    African Journals Online (AJOL)

    Background: Diffuse lung diseases constitute a major cause of morbidity and mortality worldwide. High Resolution Computed Tomography (HRCT) is the recommended imaging technique in the diagnosis, assessment and followup of these diseases. Objectives: To describe the pattern of HRCT findings in patients with ...

  4. High resolution tomographic instrument development

    International Nuclear Information System (INIS)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational

  5. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  6. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  7. Pulmonary emphysema quantitation with Computed Tomography. Comparison between the visual score with high resolution CT, expiratory density mask with spiral CT and lung function studies

    International Nuclear Information System (INIS)

    Zompatori, Maurizio; Battaglia, Milva; Rimondi, Maria Rita; Vivacqua, Donatella; Biscarini, Manuela; Fasano, Luca; Pacilli, Angela Maria Grazia; Guerrieri, Aldo; Fabbri, Mario; Cavina, Mauro

    1997-01-01

    CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of expiratory airflow obstruction and gas diffusion impairment (visual score versus forced expiratory volume in one second: r = -0.81, versus single breath carbon monoxide diffusion: r = -0.78. Spiral expiratory density mask -850 HU versus forced expiratory volume in one second: r = -0.85 versus single breath carbon monoxide diffusion: r = -0.77). When -900 HU was used as the cut-off value for the expiratory density mask, the correlation with single breath carbon monoxide diffusion worsened (r = -0.56). Visual score and expiratory density mask -850 HU gave similar results and permitted COPD patients to be clearly distinguished from normal controls (p < 0.01). They believe the true residual volume should lie somewhere in between the CT value and the function results with the helium dilution technique and conclude that the extent of pulmonary emphysema can be confidently assessed with CT methods. Finally, the simple visual score may be as reliable as such highly sophisticated new methods as the spiral expiratory density mask

  8. Dynamic high resolution imaging of rats

    International Nuclear Information System (INIS)

    Miyaoka, R.S.; Lewellen, T.K.; Bice, A.N.

    1990-01-01

    A positron emission tomography with the sensitivity and resolution to do dynamic imaging of rats would be an invaluable tool for biological researchers. In this paper, the authors determine the biological criteria for dynamic positron emission imaging of rats. To be useful, 3 mm isotropic resolution and 2-3 second time binning were necessary characteristics for such a dedicated tomograph. A single plane in which two objects of interest could be imaged simultaneously was considered acceptable. Multi-layered detector designs were evaluated as a possible solution to the dynamic imaging and high resolution imaging requirements. The University of Washington photon history generator was used to generate data to investigate a tomograph's sensitivity to true, scattered and random coincidences for varying detector ring diameters. Intrinsic spatial uniformity advantages of multi-layered detector designs over conventional detector designs were investigated using a Monte Carlo program. As a result, a modular three layered detector prototype is being developed. A module will consist of a layer of five 3.5 mm wide crystals and two layers of six 2.5 mm wide crystals. The authors believe adequate sampling can be achieved with a stationary detector system using these modules. Economical crystal decoding strategies have been investigated and simulations have been run to investigate optimum light channeling methods for block decoding strategies. An analog block decoding method has been proposed and will be experimentally evaluated to determine whether it can provide the desired performance

  9. A resolution-enhancing image reconstruction method for few-view differential phase-contrast tomography

    Science.gov (United States)

    Guan, Huifeng; Anastasio, Mark A.

    2017-03-01

    It is well-known that properly designed image reconstruction methods can facilitate reductions in imaging doses and data-acquisition times in tomographic imaging. The ability to do so is particularly important for emerging modalities such as differential X-ray phase-contrast tomography (D-XPCT), which are currently limited by these factors. An important application of D-XPCT is high-resolution imaging of biomedical samples. However, reconstructing high-resolution images from few-view tomographic measurements remains a challenging task. In this work, a two-step sub-space reconstruction strategy is proposed and investigated for use in few-view D-XPCT image reconstruction. It is demonstrated that the resulting iterative algorithm can mitigate the high-frequency information loss caused by data incompleteness and produce images that have better preserved high spatial frequency content than those produced by use of a conventional penalized least squares (PLS) estimator.

  10. High resolution CT of the lung

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Harumi (Kyoto Univ. (Japan). Faculty of Medicine)

    1991-02-01

    The emergence of computed tomography (CT) in the early 1970s has greatly contributed to diagnostic radiology. The brain was the first organ examined with CT, followed by the abdomen. For the chest, CT has also come into use shortly after the introduction in the examination of the thoracic cavity and mediastinum. CT techniques were, however, of limited significance in the evaluation of pulmonary diseases, especially diffuse pulmonary diseases. High-resolution CT (HRCT) has been introduced in clinical investigations of the lung field. This article is designed to present chest radiographic and conventional tomographic interpretations and to introduce findings of HRCT corresponding to the same shadows, with a summation of the significance of HRCT and issues of diagnostic imaging. Materials outlined are tuberculosis, pneumoconiosis, bronchopneumonia, mycoplasma pneumonia, lymphangitic carcinomatosis, sarcoidosis, diffuse panbronchiolitis, interstitial pneumonia, and pulmonary emphysema. Finally, an overview of basic investigations evolved from HRCT is given. (N.K.) 140 refs.

  11. Section on High Resolution Optical Imaging (HROI)

    Data.gov (United States)

    Federal Laboratory Consortium — The Section on High Resolution Optical Imaging (HROI) develops novel technologies for studying biological processes at unprecedented speed and resolution. Research...

  12. High Resolution Thermometry for EXACT

    Science.gov (United States)

    Panek, J. S.; Nash, A. E.; Larson, M.; Mulders, N.

    2000-01-01

    High Resolution Thermometers (HRTs) based on SQUID detection of the magnetization of a paramagnetic salt or a metal alloy has been commonly used for sub-nano Kelvin temperature resolution in low temperature physics experiments. The main applications to date have been for temperature ranges near the lambda point of He-4 (2.177 K). These thermometers made use of materials such as Cu(NH4)2Br4 *2H2O, GdCl3, or PdFe. None of these materials are suitable for EXACT, which will explore the region of the He-3/He-4 tricritical point at 0.87 K. The experiment requirements and properties of several candidate paramagnetic materials will be presented, as well as preliminary test results.

  13. High speed, High resolution terahertz spectrometers

    International Nuclear Information System (INIS)

    Kim, Youngchan; Yee, Dae Su; Yi, Miwoo; Ahn, Jaewook

    2008-01-01

    A variety of sources and methods have been developed for terahertz spectroscopy during almost two decades. Terahertz time domain spectroscopy (THz TDS)has attracted particular attention as a basic measurement method in the fields of THz science and technology. Recently, asynchronous optical sampling (AOS)THz TDS has been demonstrated, featuring rapid data acquisition and a high spectral resolution. Also, terahertz frequency comb spectroscopy (TFCS)possesses attractive features for high precision terahertz spectroscopy. In this presentation, we report on these two types of terahertz spectrometer. Our high speed, high resolution terahertz spectrometer is demonstrated using two mode locked femtosecond lasers with slightly different repetition frequencies without a mechanical delay stage. The repetition frequencies of the two femtosecond lasers are stabilized by use of two phase locked loops sharing the same reference oscillator. The time resolution of our terahertz spectrometer is measured using the cross correlation method to be 270 fs. AOS THz TDS is presented in Fig. 1, which shows a time domain waveform rapidly acquired on a 10ns time window. The inset shows a zoom into the signal with 100ps time window. The spectrum obtained by the fast Fourier Transformation (FFT)of the time domain waveform has a frequency resolution of 100MHz. The dependence of the signal to noise ratio (SNR)on the measurement time is also investigated

  14. Isotropic-resolution linear-array-based photoacoustic computed tomography through inverse Radon transform

    Science.gov (United States)

    Li, Guo; Xia, Jun; Li, Lei; Wang, Lidai; Wang, Lihong V.

    2015-03-01

    Linear transducer arrays are readily available for ultrasonic detection in photoacoustic computed tomography. They offer low cost, hand-held convenience, and conventional ultrasonic imaging. However, the elevational resolution of linear transducer arrays, which is usually determined by the weak focus of the cylindrical acoustic lens, is about one order of magnitude worse than the in-plane axial and lateral spatial resolutions. Therefore, conventional linear scanning along the elevational direction cannot provide high-quality three-dimensional photoacoustic images due to the anisotropic spatial resolutions. Here we propose an innovative method to achieve isotropic resolutions for three-dimensional photoacoustic images through combined linear and rotational scanning. In each scan step, we first elevationally scan the linear transducer array, and then rotate the linear transducer array along its center in small steps, and scan again until 180 degrees have been covered. To reconstruct isotropic three-dimensional images from the multiple-directional scanning dataset, we use the standard inverse Radon transform originating from X-ray CT. We acquired a three-dimensional microsphere phantom image through the inverse Radon transform method and compared it with a single-elevational-scan three-dimensional image. The comparison shows that our method improves the elevational resolution by up to one order of magnitude, approaching the in-plane lateral-direction resolution. In vivo rat images were also acquired.

  15. Lung scintigraphy with nonspecific human immunoglobulin G (99mTc-HIG) in the evaluation of pulmonary involvement in connective tissue diseases: correlation with pulmonary function tests (PFTs) and high-resolution computed tomography (HRCT)

    International Nuclear Information System (INIS)

    Kostopoulos, C.; Toubanakis, C.; Mamoulakis, C.; Gialafos, E.; Mavrikakis, M.; Koutsikos, J.; Zerva, C.; Leondi, A.; Moulopoulos, L.A.; Sfikakis, P.P.

    2008-01-01

    In patients with connective tissue diseases (CTD), the early detection and evaluation of the severity of the pulmonary involvement is mandatory. High-resolution computed tomography (HRCT) and pulmonary function tests (PFTs) are considered to be valuable noninvasive diagnostic modalities. Radiopharmaceuticals have also been used for this purpose. Our aim was the evaluation of technetium-labeled human polyclonal immunoglobulin G (HIG) lung scintigraphy in the early detection and assessment of the severity of the pulmonary involvement in CTD patients. Fifty-two nonsmoking CTD patients were studied by PFTs, HRCT, and HIG. According to PFTs, patients were divided in group A (impaired PFTs - abnormal pulmonary function) and group B (normal pulmonary function). Semiquantitative analysis was done on HIG and HRCT and corresponding scores were obtained. Significant difference was found between HIG scores in the two groups (0.6 ± 0.07 vs 0.51 ± 0.08, P < 0.001). There was a statistically significant negative correlation between HIG scores and PFTs results and a positive correlation between HIG and HRCT scores. HIG demonstrated similar clinical performance to HRCT. At the best cut-off levels of their score (0.56 and 7, respectively), HIG had a superior sensitivity (77.5 vs 57.5%) with lower specificity (75 vs 91.7%). The combination of the two methods increased the sensitivity of abnormal findings at the expense of specificity. HIG scintigraphy can be used in the early detection and evaluation of the severity of the pulmonary involvement in CTD, whereas, when used in combination with HRCT, the detection of affected patients can be further improved. (orig.)

  16. Microlitíase alveolar pulmonar: achados na tomografia computadorizada de alta resolução do tórax em 10 pacientes Pulmonary alveolar microlithiasis: high-resolution computed tomography findings in 10 patients

    Directory of Open Access Journals (Sweden)

    Edson Marchiori

    2007-10-01

    Full Text Available OBJETIVO: Apresentar os achados na tomografia computadorizada de alta resolução (TCAR do tórax da microlitíase alveolar pulmonar. MÉTODOS: Foram estudadas, retrospectivamente, as tomografias de dez pacientes adultos, sete mulheres e três homens, com idade média de 38,7 anos. Os exames foram analisados por dois radiologistas, de forma independente, e as decisões finais foram obtidas por consenso. RESULTADOS: Os achados mais freqüentes foram as opacidades em vidro fosco e as calcificações subpleurais, ambas presentes em 90% dos pacientes estudados. Os outros achados de maior relevância foram pequenos nódulos parenquimatosos, calcificação ao longo dos septos interlobulares, cissuras nodulares, nódulos subpleurais, cistos subpleurais, consolidações densas e padrão de pavimentação em mosaico. CONCLUSÕES: A microlitíase alveolar pulmonar apresenta aspectos na TCAR que são altamente sugestivos da doença, na maior parte dos casos dispensando a realização de biópsias pulmonares.OBJECTIVE: To present the high-resolution computed tomography (HRCT findings of pulmonary alveolar microlithiasis. METHODS: The HRCT scans of 10 adult patients (seven females and three males; mean age, 38.7 years were retrospectively analyzed. The films were studied independently by two radiologists. RESULTS: The most common tomographic findings were ground-glass attenuation and linear subpleural calcifications, which were seen in 90% of the patients. Other relevant findings were small parenchymal nodules, calcification along the interlobular septa, nodular cissures, subpleural nodules, subpleural cysts, dense consolidations, and a mosaic pattern of attenuation. CONCLUSIONS: The HRCT findings presented by individuals with pulmonary alveolar microlithiasis are distinct. In most cases, such findings can form the basis of the diagnosis, eliminating the need to perform a lung biopsy.

  17. Simultaneous dual wavelength eye-tracked ultrahigh resolution retinal and choroidal optical coherence tomography

    DEFF Research Database (Denmark)

    Unterhuber, A.; Povaay, B.; Müller, André

    2013-01-01

    We demonstrate an optical coherence tomography device that simultaneously combines different novel ultrabroad bandwidth light sources centered in the 800 and 1060 nm regions, operating at 66 kHz depth scan rate, and a confocal laser scanning ophthalmoscope-based eye tracker to permit motion......-artifact-free, ultrahigh resolution and high contrast retinal and choroidal imaging. The two wavelengths of the device provide the complementary information needed for diagnosis of subtle retinal changes, while also increasing visibility of deeper-lying layers to image pathologies that include opaque media in the anterior...... eye segment or eyes with increased choroidal thickness....

  18. High-resolution intravital microscopy.

    Directory of Open Access Journals (Sweden)

    Volker Andresen

    Full Text Available Cellular communication constitutes a fundamental mechanism of life, for instance by permitting transfer of information through synapses in the nervous system and by leading to activation of cells during the course of immune responses. Monitoring cell-cell interactions within living adult organisms is crucial in order to draw conclusions on their behavior with respect to the fate of cells, tissues and organs. Until now, there is no technology available that enables dynamic imaging deep within the tissue of living adult organisms at sub-cellular resolution, i.e. detection at the level of few protein molecules. Here we present a novel approach called multi-beam striped-illumination which applies for the first time the principle and advantages of structured-illumination, spatial modulation of the excitation pattern, to laser-scanning-microscopy. We use this approach in two-photon-microscopy--the most adequate optical deep-tissue imaging-technique. As compared to standard two-photon-microscopy, it achieves significant contrast enhancement and up to 3-fold improved axial resolution (optical sectioning while photobleaching, photodamage and acquisition speed are similar. Its imaging depth is comparable to multifocal two-photon-microscopy and only slightly less than in standard single-beam two-photon-microscopy. Precisely, our studies within mouse lymph nodes demonstrated 216% improved axial and 23% improved lateral resolutions at a depth of 80 µm below the surface. Thus, we are for the first time able to visualize the dynamic interactions between B cells and immune complex deposits on follicular dendritic cells within germinal centers (GCs of live mice. These interactions play a decisive role in the process of clonal selection, leading to affinity maturation of the humoral immune response. This novel high-resolution intravital microscopy method has a huge potential for numerous applications in neurosciences, immunology, cancer research and

  19. High-Resolution Intravital Microscopy

    Science.gov (United States)

    Andresen, Volker; Pollok, Karolin; Rinnenthal, Jan-Leo; Oehme, Laura; Günther, Robert; Spiecker, Heinrich; Radbruch, Helena; Gerhard, Jenny; Sporbert, Anje; Cseresnyes, Zoltan; Hauser, Anja E.; Niesner, Raluca

    2012-01-01

    Cellular communication constitutes a fundamental mechanism of life, for instance by permitting transfer of information through synapses in the nervous system and by leading to activation of cells during the course of immune responses. Monitoring cell-cell interactions within living adult organisms is crucial in order to draw conclusions on their behavior with respect to the fate of cells, tissues and organs. Until now, there is no technology available that enables dynamic imaging deep within the tissue of living adult organisms at sub-cellular resolution, i.e. detection at the level of few protein molecules. Here we present a novel approach called multi-beam striped-illumination which applies for the first time the principle and advantages of structured-illumination, spatial modulation of the excitation pattern, to laser-scanning-microscopy. We use this approach in two-photon-microscopy - the most adequate optical deep-tissue imaging-technique. As compared to standard two-photon-microscopy, it achieves significant contrast enhancement and up to 3-fold improved axial resolution (optical sectioning) while photobleaching, photodamage and acquisition speed are similar. Its imaging depth is comparable to multifocal two-photon-microscopy and only slightly less than in standard single-beam two-photon-microscopy. Precisely, our studies within mouse lymph nodes demonstrated 216% improved axial and 23% improved lateral resolutions at a depth of 80 µm below the surface. Thus, we are for the first time able to visualize the dynamic interactions between B cells and immune complex deposits on follicular dendritic cells within germinal centers (GCs) of live mice. These interactions play a decisive role in the process of clonal selection, leading to affinity maturation of the humoral immune response. This novel high-resolution intravital microscopy method has a huge potential for numerous applications in neurosciences, immunology, cancer research and developmental biology

  20. Imaging of basal cell carcinoma by high-definition optical coherence tomography

    DEFF Research Database (Denmark)

    Boone, M A L M; Norrenberg, S; Jemec, G B E

    2012-01-01

    With the continued development of noninvasive therapies for basal cell carcinoma (BCC) such as photodynamic therapy and immune therapies, noninvasive diagnosis and monitoring become increasingly relevant. High-definition optical coherence tomography (HD-OCT) is a high-resolution imaging tool, wit......, with micrometre resolution in both transversal and axial directions, enabling visualization of individual cells up to a depth of around 570 μm, and filling the imaging gap between conventional optical coherence tomography (OCT) and reflectance confocal microscopy (RCM)....

  1. High-Resolution Mass Spectrometers

    Science.gov (United States)

    Marshall, Alan G.; Hendrickson, Christopher L.

    2008-07-01

    Over the past decade, mass spectrometry has been revolutionized by access to instruments of increasingly high mass-resolving power. For small molecules up to ˜400 Da (e.g., drugs, metabolites, and various natural organic mixtures ranging from foods to petroleum), it is possible to determine elemental compositions (CcHhNnOoSsPp…) of thousands of chemical components simultaneously from accurate mass measurements (the same can be done up to 1000 Da if additional information is included). At higher mass, it becomes possible to identify proteins (including posttranslational modifications) from proteolytic peptides, as well as lipids, glycoconjugates, and other biological components. At even higher mass (˜100,000 Da or higher), it is possible to characterize posttranslational modifications of intact proteins and to map the binding surfaces of large biomolecule complexes. Here we review the principles and techniques of the highest-resolution analytical mass spectrometers (time-of-flight and Fourier transform ion cyclotron resonance and orbitrap mass analyzers) and describe some representative high-resolution applications.

  2. Ultra-high resolution AMOLED

    Science.gov (United States)

    Wacyk, Ihor; Prache, Olivier; Ghosh, Amal

    2011-06-01

    AMOLED microdisplays continue to show improvement in resolution and optical performance, enhancing their appeal for a broad range of near-eye applications such as night vision, simulation and training, situational awareness, augmented reality, medical imaging, and mobile video entertainment and gaming. eMagin's latest development of an HDTV+ resolution technology integrates an OLED pixel of 3.2 × 9.6 microns in size on a 0.18 micron CMOS backplane to deliver significant new functionality as well as the capability to implement a 1920×1200 microdisplay in a 0.86" diagonal area. In addition to the conventional matrix addressing circuitry, the HDTV+ display includes a very lowpower, low-voltage-differential-signaling (LVDS) serialized interface to minimize cable and connector size as well as electromagnetic emissions (EMI), an on-chip set of look-up-tables for digital gamma correction, and a novel pulsewidth- modulation (PWM) scheme that together with the standard analog control provides a total dimming range of 0.05cd/m2 to 2000cd/m2 in the monochrome version. The PWM function also enables an impulse drive mode of operation that significantly reduces motion artifacts in high speed scene changes. An internal 10-bit DAC ensures that a full 256 gamma-corrected gray levels are available across the entire dimming range, resulting in a measured dynamic range exceeding 20-bits. This device has been successfully tested for operation at frame rates ranging from 30Hz up to 85Hz. This paper describes the operational features and detailed optical and electrical test results for the new AMOLED WUXGA resolution microdisplay.

  3. High resolution, high speed ultrahigh vacuum microscopy

    International Nuclear Information System (INIS)

    Poppa, Helmut

    2004-01-01

    The history and future of transmission electron microscopy (TEM) is discussed as it refers to the eventual development of instruments and techniques applicable to the real time in situ investigation of surface processes with high resolution. To reach this objective, it was necessary to transform conventional high resolution instruments so that an ultrahigh vacuum (UHV) environment at the sample site was created, that access to the sample by various in situ sample modification procedures was provided, and that in situ sample exchanges with other integrated surface analytical systems became possible. Furthermore, high resolution image acquisition systems had to be developed to take advantage of the high speed imaging capabilities of projection imaging microscopes. These changes to conventional electron microscopy and its uses were slowly realized in a few international laboratories over a period of almost 40 years by a relatively small number of researchers crucially interested in advancing the state of the art of electron microscopy and its applications to diverse areas of interest; often concentrating on the nucleation, growth, and properties of thin films on well defined material surfaces. A part of this review is dedicated to the recognition of the major contributions to surface and thin film science by these pioneers. Finally, some of the important current developments in aberration corrected electron optics and eventual adaptations to in situ UHV microscopy are discussed. As a result of all the path breaking developments that have led to today's highly sophisticated UHV-TEM systems, integrated fundamental studies are now possible that combine many traditional surface science approaches. Combined investigations to date have involved in situ and ex situ surface microscopies such as scanning tunneling microscopy/atomic force microscopy, scanning Auger microscopy, and photoemission electron microscopy, and area-integrating techniques such as x-ray photoelectron

  4. Investigation of spatial resolution characteristics of an in vivo microcomputed tomography system

    Energy Technology Data Exchange (ETDEWEB)

    Ghani, Muhammad U. [Center for Biomedical engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019 (United States); Zhou, Zhongxing [Center for Biomedical engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019 (United States); School of Precision and Optoelectronics Engineering, Tianjin University, Tianjin 300072 (China); Ren, Liqiang; Wong, Molly; Li, Yuhua; Zheng, Bin [Center for Biomedical engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019 (United States); Yang, Kai [Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114 (United States); Liu, Hong, E-mail: liu@ou.edu [Center for Biomedical engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019 (United States)

    2016-01-21

    The spatial resolution characteristics of an in vivo microcomputed tomography (CT) system was investigated in the in-plane (x–y), cross plane (z) and projection imaging modes. The microCT system utilized in this study employs a flat panel detector with a 127 µm pixel pitch, a microfocus x-ray tube with a focal spot size ranging from 5–30 µm, and accommodates three geometric magnifications (M) of 1.72, 2.54 and 5.10. The in-plane modulation transfer function (MTF) curves were measured as a function of the number of projections, geometric magnification (M), detector binning and reconstruction magnification (M{sub Recon}). The in plane cutoff frequency (10% MTF) ranged from 2.31 lp/mm (M=1.72, 2×2 binning) to 12.56 lp/mm (M=5.10, 1×1 binning) and a bar pattern phantom validated those measurements. A slight degradation in the spatial resolution was observed when comparing the image reconstruction with 511 and 918 projections, whose effect was visible at the lower frequencies. Small value of M{sub Recon} has little or no impact on the in-plane spatial resolution owning to a stable system. Large value of M{sub Recon} has implications on the spatial resolution and it was evident when comparing the bar pattern images reconstructed with M{sub Recon}=1.25 and 2.5. The cross plane MTF curves showed that the spatial resolution increased as the slice thickness decreased. The cutoff frequencies in the projection imaging mode yielded slightly higher values as compared to the in-plane and cross plane modes at all the geometric magnifications (M). At M=5.10, the cutoff resolution of the projection and cross plane on an ultra-high contrast resolution bar chip phantom were 14.9 lp/mm and 13–13.5 lp/mm. Due to the finite focal spot size of the x-ray tube, the detector blur and the reconstruction kernel functions, the system's spatial resolution does not reach the limiting spatial resolution as defined by the Nyquist's detector criteria with an ideal point source

  5. Microstructural abnormalities in MEWDS demonstrated by ultrahigh resolution optical coherence tomography.

    Science.gov (United States)

    Nguyen, My Hanh T; Witkin, Andre J; Reichel, Elias; Ko, Tony H; Fujimoto, James G; Schuman, Joel S; Duker, Jay S

    2007-01-01

    Histopathological studies of acute multiple evanescent white dot syndrome (MEWDS) have not been reported because of the transient and benign nature of the disease. Ultrahigh resolution optical coherence tomography (UHR-OCT), capable of high resolution in vivo imaging, offers a unique opportunity to visualize retinal microstructure in the disease. UHR-OCT images of the maculae of five patients with MEWDS were obtained and analyzed. Diagnosis was based on clinical presentation, examination, visual field testing, and angiography. UHR-OCT revealed disturbances in the photoreceptor inner/outer segment junction (IS/OS) in each of the five patients (six eyes) with MEWDS. In addition, thinning of the outer nuclear layer was seen in the case of recurrent MEWDS, suggesting that repeated episodes of MEWDS may result in photoreceptor atrophy. Subtle disruptions of the photoreceptor IS/OS are demonstrated in all eyes affected by MEWDS. UHR-OCT may be a useful adjunct to diagnosis and monitoring of MEWDS.

  6. High-definition velocity-space tomography of fast-ion dynamics

    DEFF Research Database (Denmark)

    Salewski, Mirko; Geiger, B.; Jacobsen, A.S.

    2016-01-01

    Velocity-space tomography of the fast-ion distribution function in a fusion plasma is usually a photon-starved tomography method due to limited optical access and signal-to-noise ratio of fast-ion Dα (FIDA) spectroscopy as well as the strive for high-resolution images. In high-definition tomography...... information to reconstruct where in velocity space the measurements and the simulation disagree. This alternative approach is demonstrated for four-view as well as for two-view FIDA measurements. The high-definition tomography tools allow us to study fast ions in sawtoothing plasmas and the formation of NBI...

  7. High-resolution ultrasonic spectroscopy

    Directory of Open Access Journals (Sweden)

    V. Buckin

    2018-03-01

    Full Text Available High-resolution ultrasonic spectroscopy (HR-US is an analytical technique for direct and non-destructive monitoring of molecular and micro-structural transformations in liquids and semi-solid materials. It is based on precision measurements of ultrasonic velocity and attenuation in analysed samples. The application areas of HR-US in research, product development, and quality and process control include analysis of conformational transitions of polymers, ligand binding, molecular self-assembly and aggregation, crystallisation, gelation, characterisation of phase transitions and phase diagrams, and monitoring of chemical and biochemical reactions. The technique does not require optical markers or optical transparency. The HR-US measurements can be performed in small sample volumes (down to droplet size, over broad temperature range, at ambient and elevated pressures, and in various measuring regimes such as automatic temperature ramps, titrations and measurements in flow.

  8. High resolution eddy current microscopy

    Science.gov (United States)

    Lantz, M. A.; Jarvis, S. P.; Tokumoto, H.

    2001-01-01

    We describe a sensitive scanning force microscope based technique for measuring local variations in resistivity by monitoring changes in the eddy current induced damping of a cantilever with a magnetic tip oscillating above a conducting sample. To achieve a high sensitivity, we used a cantilever with an FeNdBLa particle mounted on the tip. Resistivity measurements are demonstrated on a silicon test structure with a staircase doping profile. Regions with resistivities of 0.0013, 0.0041, and 0.022 Ω cm are clearly resolved with a lateral resolution of approximately 180 nm. For this range of resistivities, the eddy current induced damping is found to depend linearly on the sample resistivity.

  9. Oversampling in the computed tomography measurements applied for bone structure studies as a method of spatial resolution improvement

    International Nuclear Information System (INIS)

    Tatoń, Grzegorz; Rokita, Eugeniusz; Rok, Tomasz; Beckmann, Felix

    2012-01-01

    Our purpose was to check the potential ability of oversampling as a method for computed tomography axial resolution improvement. The method of achieving isotropic and fine resolution, when the scanning system is characterized by anisotropic resolutions is proposed. In case of typical clinical system the axial resolution is much lower than the planar one. The idea relies on the scanning with a wide overlapping layers and subsequent resolution recovery on the level of scanning step. Simulated three-dimensional images, as well as the real microtomographic images of rat femoral bone were used in proposed solution tests. Original high resolution images were virtually scanned with a wide beam and a small step in order to simulate the real measurements. The low resolution image series were subsequently processed in order to back to the original fine one. Original, virtually scanned and recovered images resolutions were compared with the use of modulation transfer function (MTF). A good ability of oversampling as a method for the resolution recovery was showed. It was confirmed by comparing the resolving powers after and before resolution recovery. The MTF analysis showed resolution improvement. The resolution improvement was achieved but the image noise raised considerably, which is clearly visible on image histograms. Despite this disadvantage the proposed method can be successfully used in practice, especially in the trabecular bone studies because of high contrast between trabeculae and intertrabecular spaces

  10. Measurement on the density resolution of industrial computerized tomography by using disc specimen with holes

    International Nuclear Information System (INIS)

    Tian, Y.; Gao, D.; Zhang, W.; Xia, Z.; Yang, C.

    2004-01-01

    Several ways mainly used for measuring the density resolution of industrial computerized tomography (ICT) are briefly introduced. Based on the equivalent conversion between volume variation and density variation, a kind of disc specimen with holes is designed to measure the density resolution of ICT. In this experiment, a kind of high quality polymethyl methacylate (PMMA) is selected to make specimens with diameter of 250mm, in which six sets of holes with diameter separately 0.5mm, 1.0mm, 1.5mm, 2.0mm, 2.5mm, and 3.0mm are distributed in the radial directions with interval of 60 o between two neighboring sets, and in the same set, the distances of holes departing the center of the specimen are respectively 20mm, 40mm, 60mm, 80mm, and 100mm. The experiment shows that the method is sensitive, simple, flexible, and practical. About 0.2% density resolution of region of interest (ROI) with diameter 20mm can be verified, the relationship between CT value of ROI and its position can be obtained, and at the same time the spatial resolution of ICT can be measured in high quality. (author)

  11. The demonstration of the auditory ossicles by high resolution CT

    International Nuclear Information System (INIS)

    Lloyd, G.A.S.; Boulay, G.H. du; Phelps, P.D.; Pullicino, P.

    1979-01-01

    The high resolution CT scanning system introduced by EMI in 1978 has added a new dimension to computerised tomography in otology. The apparatus used for this study was an EMI CT 5005 body scanner adapted for head and neck scanning and incorporating a high resolution facility. The latter has proved most advantageous in areas of relatively high differential absorption, so that its application to the demonstration of abnormalities in the petrous temporal bone, and in particular middle ear disease, has been very rewarding. Traumatic ossicular disruptions may now be demonstrated and the high contrast of CT often shows them better than conventional hypocycloidal tomography. The stapes is also better visualised and congenital abnormalities of its superstructure have been recorded. These studies have been achieved with a very acceptable level of radiation to the eye, lens and cornea and the technique is clearly a rival to conventional pluridirectional tomography in the assessment of the petrous temporal bone. With further design improvements high resolution CT could completely replace existing techniques. (orig.) [de

  12. High resolution CT in obstructive and air-ways lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Webb, W R [California Univ., San Francisco, CA (United States). Dept. of Radiology

    1996-12-31

    The topics briefly discussed i.e. emphysema, its diagnosis, bronchiectasis etc. HRTC (high resolution computerized tomography) in diagnosing both disease and small airways abnormalities also discussed. (33 refs.).

  13. High resolution CT in obstructive and air-ways lung disease

    International Nuclear Information System (INIS)

    Webb, W.R.

    1995-01-01

    The topics briefly discussed i.e. emphysema, its diagnosis, bronchiectasis etc. HRTC (high resolution computerized tomography) in diagnosing both disease and small airways abnormalities also discussed. (33 refs.)

  14. Tuberculous otitis media: findings on high-resolution CT

    International Nuclear Information System (INIS)

    Lungenschmid, D.; Buchberger, W.; Schoen, G.; Schoepf, R.; Mihatsch, T.; Birbamer, G.; Wicke, K.

    1993-01-01

    We describe two cases of tuberculous otitis media studied with high-resolution computed tomography (CT). Findings included extensive soft tissue densities with fluid levels in the tympanic cavity, the antrum, the mastoid and petrous air cells. Multifocal bony erosions and reactive bone sclerosis were seen as well. CT proved valuable for planning therapy by accurately displaying the involvement of the various structures of the middle and inner ear. However, the specific nature of the disease could only be presumed. (orig.)

  15. Development of AMS high resolution injector system

    International Nuclear Information System (INIS)

    Bao Yiwen; Guan Xialing; Hu Yueming

    2008-01-01

    The Beijing HI-13 tandem accelerator AMS high resolution injector system was developed. The high resolution energy achromatic system consists of an electrostatic analyzer and a magnetic analyzer, which mass resolution can reach 600 and transmission is better than 80%. (authors)

  16. Advanced Technologies for Ultrahigh Resolution and Functional Optical Coherence Tomography

    Science.gov (United States)

    2008-04-15

    Gorczynska, "Frequency domain optical coherence tomography techniques in eye imaging," Acta Physica Polonica A , vol. 102, pp. 739-46, 2002/12/ 2002. [57] S...other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a ...SUPPLEMENTARY NOTES 14. ABSTRACT 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: a . REPORT b. ABSTRACT c. THIS PAGE 17. LIMITATION OF ABSTRACT

  17. A Very High Spatial Resolution Detector for Small Animal PET

    International Nuclear Information System (INIS)

    Kanai Shah, M.S.

    2007-01-01

    Positron Emission Tomography (PET) is an in vivo analog of autoradiography and has the potential to become a powerful new tool in imaging biological processes in small laboratory animals. PET imaging of small animals can provide unique information that can help in advancement of human disease models as well as drug development. Clinical PET scanners used for human imaging are bulky, expensive and do not have adequate spatial resolution for small animal studies. Hence, dedicated, low cost instruments are required for conducting small animal studies with higher spatial resolution than what is currently achieved with clinical as well as dedicated small animal PET scanners. The goal of the proposed project is to investigate a new all solid-state detector design for small animal PET imaging. Exceptionally high spatial resolution, good timing resolution, and excellent energy resolution are expected from the proposed detector design. The Phase I project was aimed at demonstrating the feasibility of producing high performance solid-state detectors that provide high sensitivity, spatial resolution, and timing characteristics. Energy resolution characteristics of the new detector were also investigated. The goal of the Phase II project is to advance the promising solid-state detector technology for small animal PET and determine its full potential. Detectors modules will be built and characterized and finally, a bench-top small animal PET system will be assembled and evaluated

  18. The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas; CT und MRT des erworbenen Cholesteatoms: Prae- und postoperative Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Krestan, C.; Czerny, C. [Abteilung fuer Osteologie, Univ.-Klinik fuer Radiodiagnostik, Wien (Austria); Gstoettner, W. [Univ.-Klinik fuer Hals-Nasen-Ohren-Heilkunde, Frankfurt (Germany); Franz, P. [Univ.-Klinik fuer Hals-Nasen-Ohren-Heilkunde, Wien (Austria)

    2003-03-01

    The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions caused by recurrent cholesteatoma, bony defects of the facial nerve and of the labyrinth, and a defect of the tegmen tympani with a soft tissue mass in the middle ear. Postoperative MRI delineated neuritis of the facial nerve, labyrinthitis, and a meningo-encephalocele protruding into the middle ear. HRCT and MRI are excellent imaging tools to depict either bony or soft tissue complications or both if caused by acquired cholesteatomas. According to our findings and to the literature HRCT and MRI are complementary imaging methods to depict pre- or postoperative complications of acquired cholesteatomas if these are suspected by clinical examination. (orig.) [German] In dieser Arbeit wird die Rolle der hochaufloesenden Computertomographie (HRCT) und der Magnetresonanztomographie (MRT) zur Abklaerung prae- und postoperativ bedingter Komplikationen erworbener Cholesteatome beschrieben. Die Bildgebung wurde sowohl mit der HRCT als auch mit der MRT durchgefuehrt. Die HRCT und die MRT wurden in axialer und koronaler Ebene (auch

  19. High-resolution nuclear magnetic resonance imaging and single photon emission computerized tomography--cerebral blood flow in a case of pure sensory stroke and mild dementia owing to subcortical arteriosclerotic encephalopathy (Binswanger's disease)

    DEFF Research Database (Denmark)

    De Chiara, S; Lassen, N A; Andersen, A R

    1987-01-01

    hypertensive, 72-year-old patient with PSS, CT scanning and conventional nuclear magnetic resonance imaging (NMRI) scanning using a 7-mm-thick slice on a 1.5 Tesla instrument all failed to visualize the thalamic infarct. Using the high-resolution mode with 2-mm slice thickness it was, however, clearly seen...

  20. High-resolution electron microscopy

    CERN Document Server

    Spence, John C H

    2013-01-01

    This new fourth edition of the standard text on atomic-resolution transmission electron microscopy (TEM) retains previous material on the fundamentals of electron optics and aberration correction, linear imaging theory (including wave aberrations to fifth order) with partial coherence, and multiple-scattering theory. Also preserved are updated earlier sections on practical methods, with detailed step-by-step accounts of the procedures needed to obtain the highest quality images of atoms and molecules using a modern TEM or STEM electron microscope. Applications sections have been updated - these include the semiconductor industry, superconductor research, solid state chemistry and nanoscience, and metallurgy, mineralogy, condensed matter physics, materials science and material on cryo-electron microscopy for structural biology. New or expanded sections have been added on electron holography, aberration correction, field-emission guns, imaging filters, super-resolution methods, Ptychography, Ronchigrams, tomogr...

  1. High-speed X-ray phase tomography with Talbot interferometer and fringe scanning method

    International Nuclear Information System (INIS)

    Kibayashi, Shunsuke; Harasse, Sébastien; Yashiro, Wataru; Momose, Atsushi

    2012-01-01

    High-speed X-ray phase tomography based on the Fourier-transform method has been demonstrated with an X-ray Talbot interferometer using white synchrotron radiation. We report the experimental results of high-speed X-ray phase tomography with fringe-scanning method instead of Fourier-transform method to improve spatial resolution without a considerable increase of scan time. To apply fringe-scanning method to high speed tomography, we tested a scan that is a synchronous combination of one-way continuous movements of the sample rotation and the grating displacement. When this scanning method was combined with X-ray phase tomography, we were able to obtain a scan time of 5 s. A comparison of the image quality derived with the conventional approach and with the proposed approach using the fringe-scanning method showed that the latter had better spatial resolution.

  2. Zeolites - a high resolution electron microscopy study

    International Nuclear Information System (INIS)

    Alfredsson, V.

    1994-10-01

    High resolution transmission electron microscopy (HRTEM) has been used to investigate a number of zeolites (EMT, FAU, LTL, MFI and MOR) and a member of the mesoporous M41S family. The electron optical artefact, manifested as a dark spot in the projected centre of the large zeolite channels, caused by insufficient transfer of certain reflections in the objective lens has been explained. The artefact severely hinders observation of materials confined in the zeolite channels and cavities. It is shown how to circumvent the artefact problem and how to image confined materials in spite of disturbance caused by the artefact. Image processing by means of a Wiener filter has been applied for removal of the artefact. The detailed surface structure of FAU has been investigated. Comparison of experimental micrographs with images simulated using different surface models indicates that the surface can be terminated in different ways depending on synthesis methods. The dealuminated form of FAU (USY) is covered by an amorphous region. Platinum incorporated in FAU has a preponderance to aggregate in the (111) twin planes, probably due to a local difference in cage structure with more spacious cages. It is shown that platinum is intra-zeolitic as opposed to being located on the external surface of the zeolite crystal. This could be deduced from tomography of ultra-thin sections among observations. HRTEM studies of the mesoporous MCM-41 show that the pores have a hexagonal shape and also supports the mechanistic model proposed which involves a cooperative formation of a mesophase including the silicate species as well as the surfactant. 66 refs, 24 figs

  3. Resolution tests of global geodynamic models by travel-time tomography

    Czech Academy of Sciences Publication Activity Database

    Běhounková, Marie; Čížková, H.; Matyska, C.

    2005-01-01

    Roč. 49, č. 3 (2005), s. 343-363 ISSN 0039-3169 R&D Projects: GA ČR GA205/02/1306 Institutional research plan: CEZ:AV0Z30120515 Keywords : seismic tomography * synthetic inversion * resolution tests Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 0.656, year: 2005

  4. Digital adaptive optics for achieving space-invariant lateral resolution in optical coherence tomography

    International Nuclear Information System (INIS)

    Kumar, A.

    2015-01-01

    Optical coherence tomography (OCT) is a non-invasive optical interferometric imaging technique that provides reflectivity profiles of the sample structures with high axial resolution. The high axial resolution is due to the use of low coherence (broad-band) light source. However, the lateral resolution in OCT depends on the numerical aperture (NA) of the focusing/imaging optics and it is affected by defocus and other higher order optical aberrations induced by the imperfect optics, or by the sample itself.Hardware based adaptive optics (AO) has been successfully combined with OCT to achieve high lateral resolution in combination with high axial resolution provided by OCT. AO, which conventionally uses Shack-Hartmann wavefront sensor (SH WFS) and deformable mirror for wavefront sensing and correction respectively, can compensate for optical aberration and can enable diffraction-limited resolution in OCT. Visualization of cone photoreceptors in 3-D has been successfully demonstrated using AO-OCT. However, OCT being an interferometric imaging technique can provide access to phase information.This phase information can be exploited by digital adaptive optics (DAO) techniques to correct optical aberration in the post-processing step to obtain diffraction-limited space invariant lateral resolution throughout the image volume. Thus, the need for hardware based AO can be eliminated, which in turn can reduce the system complexity and economical cost. In the first paper of this thesis, a novel DAO method based on sub-aperture correlation is presented which is the digital equivalent of SH WFS. The advantage of this method is that it is non-iterative in nature and it does not require a priori knowledge of any system parameters such wavelength, focal length, NA or detector pixel size. For experimental proof, a FF SS OCT system was used and the sample consisted of resolution test target and a plastic plate that introduced random optical aberration. Experimental results show that

  5. Improvements in high energy computed tomography

    International Nuclear Information System (INIS)

    Burstein, P.; Krieger, A.; Annis, M.

    1984-01-01

    In computerized axial tomography employed with large relatively dense objects such as a solid fuel rocket engine, using high energy x-rays, such as a 15 MeV source, a collimator is employed with an acceptance angle substantially less than 1 0 , in a preferred embodiment 7 minutes of a degree. In a preferred embodiment, the collimator may be located between the object and the detector, although in other embodiments, a pre-collimator may also be used, that is between the x-ray source and the object being illuminated. (author)

  6. Enhanced spatial resolution in fluorescence molecular tomography using restarted L1-regularized nonlinear conjugate gradient algorithm.

    Science.gov (United States)

    Shi, Junwei; Liu, Fei; Zhang, Guanglei; Luo, Jianwen; Bai, Jing

    2014-04-01

    Owing to the high degree of scattering of light through tissues, the ill-posedness of fluorescence molecular tomography (FMT) inverse problem causes relatively low spatial resolution in the reconstruction results. Unlike L2 regularization, L1 regularization can preserve the details and reduce the noise effectively. Reconstruction is obtained through a restarted L1 regularization-based nonlinear conjugate gradient (re-L1-NCG) algorithm, which has been proven to be able to increase the computational speed with low memory consumption. The algorithm consists of inner and outer iterations. In the inner iteration, L1-NCG is used to obtain the L1-regularized results. In the outer iteration, the restarted strategy is used to increase the convergence speed of L1-NCG. To demonstrate the performance of re-L1-NCG in terms of spatial resolution, simulation and physical phantom studies with fluorescent targets located with different edge-to-edge distances were carried out. The reconstruction results show that the re-L1-NCG algorithm has the ability to resolve targets with an edge-to-edge distance of 0.1 cm at a depth of 1.5 cm, which is a significant improvement for FMT.

  7. Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography

    Science.gov (United States)

    Herz, P. R.; Chen, Y.; Aguirre, A. D.; Schneider, K.; Hsiung, P.; Fujimoto, J. G.; Madden, K.; Schmitt, J.; Goodnow, J.; Petersen, C.

    2004-10-01

    A distally actuated, rotational-scanning micromotor endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with micromotor endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications.

  8. Theoretical limit of spatial resolution in diffuse optical tomography using a perturbation model

    International Nuclear Information System (INIS)

    Konovalov, A B; Vlasov, V V

    2014-01-01

    We have assessed the limit of spatial resolution of timedomain diffuse optical tomography (DOT) based on a perturbation reconstruction model. From the viewpoint of the structure reconstruction accuracy, three different approaches to solving the inverse DOT problem are compared. The first approach involves reconstruction of diffuse tomograms from straight lines, the second – from average curvilinear trajectories of photons and the third – from total banana-shaped distributions of photon trajectories. In order to obtain estimates of resolution, we have derived analytical expressions for the point spread function and modulation transfer function, as well as have performed a numerical experiment on reconstruction of rectangular scattering objects with circular absorbing inhomogeneities. It is shown that in passing from reconstruction from straight lines to reconstruction using distributions of photon trajectories we can improve resolution by almost an order of magnitude and exceed the accuracy of reconstruction of multi-step algorithms used in DOT. (optical tomography)

  9. Planning for shallow high resolution seismic surveys

    CSIR Research Space (South Africa)

    Fourie, CJS

    2008-11-01

    Full Text Available of the input wave. This information can be used in conjunction with this spreadsheet to aid the geophysicist in designing shallow high resolution seismic surveys to achieve maximum resolution and penetration. This Excel spreadsheet is available free from...

  10. Fast iterative segmentation of high resolution medical images

    International Nuclear Information System (INIS)

    Hebert, T.J.

    1996-01-01

    Various applications in positron emission tomography (PET), single photon emission computed tomography (SPECT) and magnetic resonance imaging (MRI) require segmentation of 20 to 60 high resolution images of size 256x256 pixels in 3-9 seconds per image. This places particular constraints on the design of image segmentation algorithms. This paper examines the trade-offs in segmenting images based on fitting a density function to the pixel intensities using curve-fitting versus the maximum likelihood method. A quantized data representation is proposed and the EM algorithm for fitting a finite mixture density function to the quantized representation for an image is derived. A Monte Carlo evaluation of mean estimation error and classification error showed that the resulting quantized EM algorithm dramatically reduces the required computation time without loss of accuracy

  11. High resolution NMR in zeolites

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, Anix [INTEVEP, Filial de Petroleos de Venezuela, SA, Caracas (Venezuela). Dept. de Analisis y Evalucion

    1992-12-31

    In this work {sup 29} Si and {sup 27} Al NMR spectroscopy was used to study various types of zeolites. The corresponding spectra were used to measure the Si/Al ratios, to follow chemical modifications induced by acid and hydrothermal treatments, to determine non-equivalent crystallographic sites in highly dealuminated mordenites, and to detect modifications of faujasites due to the insertion of titanium atoms in the lattice. (author) 7 refs., 7 figs., 2 tabs.

  12. High resolution NMR in zeolites

    International Nuclear Information System (INIS)

    Diaz, Anix

    1991-01-01

    In this work 29 Si and 27 Al NMR spectroscopy was used to study various types of zeolites. The corresponding spectra were used to measure the Si/Al ratios, to follow chemical modifications induced by acid and hydrothermal treatments, to determine non-equivalent crystallographic sites in highly dealuminated mordenites, and to detect modifications of faujasites due to the insertion of titanium atoms in the lattice. (author)

  13. Signal Amplification Technique (SAT): an approach for improving resolution and reducing image noise in computed tomography

    International Nuclear Information System (INIS)

    Phelps, M.E.; Huang, S.C.; Hoffman, E.J.; Plummer, D.; Carson, R.

    1981-01-01

    Spatial resolution improvements in computed tomography (CT) have been limited by the large and unique error propagation properties of this technique. The desire to provide maximum image resolution has resulted in the use of reconstruction filter functions designed to produce tomographic images with resolution as close as possible to the intrinsic detector resolution. Thus, many CT systems produce images with excessive noise with the system resolution determined by the detector resolution rather than the reconstruction algorithm. CT is a rigorous mathematical technique which applies an increasing amplification to increasing spatial frequencies in the measured data. This mathematical approach to spatial frequency amplification cannot distinguish between signal and noise and therefore both are amplified equally. We report here a method in which tomographic resolution is improved by using very small detectors to selectively amplify the signal and not noise. Thus, this approach is referred to as the signal amplification technique (SAT). SAT can provide dramatic improvements in image resolution without increases in statistical noise or dose because increases in the cutoff frequency of the reconstruction algorithm are not required to improve image resolution. Alternatively, in cases where image counts are low, such as in rapid dynamic or receptor studies, statistical noise can be reduced by lowering the cutoff frequency while still maintaining the best possible image resolution. A possible system design for a positron CT system with SAT is described

  14. High-resolution CT of lymphoid interstitial pneumonia

    International Nuclear Information System (INIS)

    Vilgrain, V.; Frija, J.; Yana, C.; Couderc, L.J.; David, M.; Clauvel, J.P.; Laval-Jeantet, M.

    1989-01-01

    Three patients with lymphoid interstitial pneumonia (two HIV 1+ patients with chronic lymphadenopathic syndromes and one with a not-characterized autoimmune disease) have been studied with high-resolution computed tomography (HR-CT). This technique reveals septal lines, small reticulonodular opacities, polyhedral micronodular opacities, 'ground-glass' opacities and a dense, subpleural, curved broken line in one patient. The lesions dominate in the bases of the lungs. They are not characteristic for lymphoid interstitial pneumonia. If a patient presents with a chronic lymphadenopathic syndrome, the diagnosis of an opportunistic infection should not be automatically made, since the syndrome can be caused by lymphoid interstitial pneumonia [fr

  15. High resolution sequence stratigraphy in China

    International Nuclear Information System (INIS)

    Zhang Shangfeng; Zhang Changmin; Yin Yanshi; Yin Taiju

    2008-01-01

    Since high resolution sequence stratigraphy was introduced into China by DENG Hong-wen in 1995, it has been experienced two development stages in China which are the beginning stage of theory research and development of theory research and application, and the stage of theoretical maturity and widely application that is going into. It is proved by practices that high resolution sequence stratigraphy plays more and more important roles in the exploration and development of oil and gas in Chinese continental oil-bearing basin and the research field spreads to the exploration of coal mine, uranium mine and other strata deposits. However, the theory of high resolution sequence stratigraphy still has some shortages, it should be improved in many aspects. The authors point out that high resolution sequence stratigraphy should be characterized quantitatively and modelized by computer techniques. (authors)

  16. High resolution CT of the chest

    Energy Technology Data Exchange (ETDEWEB)

    Barneveld Binkhuysen, F H [Eemland Hospital (Netherlands), Dept. of Radiology

    1996-12-31

    Compared to conventional CT high resolution CT (HRCT) shows several extra anatomical structures which might effect both diagnosis and therapy. The extra anatomical structures were discussed briefly in this article. (18 refs.).

  17. High-resolution spectrometer at PEP

    International Nuclear Information System (INIS)

    Weiss, J.M.; HRS Collaboration.

    1982-01-01

    A description is presented of the High Resolution Spectrometer experiment (PEP-12) now running at PEP. The advanced capabilities of the detector are demonstrated with first physics results expected in the coming months

  18. High Speed impedance tomography for cardiac imaging

    International Nuclear Information System (INIS)

    Tehrani, J.N.; Jin, C.; Schaik, Andre

    2010-01-01

    Full text: Electrical Impedance Tomography (EIT) calculates the internal conductivity distribution within a body using electrical contact measurements. Previous investigation has shown that optimizing electrode placement can give better information about the stroke volume and better separation between the ventricles and atria than with the electrodes attached in the transverse plane. In our investigation we are developing fast three dimensional imaging of the heart (two planes of 16 electrodes) including internal electrodes in esophagus. The reconstruction speed in EIT is one of the main limitations for real time imaging when using a detailed three dimensional finite element mesh. For that reason we investigated new iterative algorithms for solving large scale LJ regularization. In this research we compare these algorithms on noise reliability and speed for 2D cardiac models. The four methods were as follows: (I) an interior point method for solving Ll-regularized least squares problems (Ll-LS); (2) total variation using a Lagrangian multiplier (TV AL3); (3) a two step iterative shrinkage/thresholding method (TWIST) for solving the Lo-regularized least squares problem; (4) The Least Absolute Shrinkage and Selection Operator (LASSO). In our investigation, using 1600 elements, we found all four algorithms provided an improvement over the best conventional EIT reconstruction method, Total Variation, in three important areas: robustness to noise, increased computational speed of at least 40 x and a visually apparent improvement in spatial resolution. Out of the four algorithms we found TWIST was the fastest with at least a 1 00 x speed increase. (author)

  19. Ultra-high resolution coded wavefront sensor

    KAUST Repository

    Wang, Congli

    2017-06-08

    Wavefront sensors and more general phase retrieval methods have recently attracted a lot of attention in a host of application domains, ranging from astronomy to scientific imaging and microscopy. In this paper, we introduce a new class of sensor, the Coded Wavefront Sensor, which provides high spatio-temporal resolution using a simple masked sensor under white light illumination. Specifically, we demonstrate megapixel spatial resolution and phase accuracy better than 0.1 wavelengths at reconstruction rates of 50 Hz or more, thus opening up many new applications from high-resolution adaptive optics to real-time phase retrieval in microscopy.

  20. Structure of high-resolution NMR spectra

    CERN Document Server

    Corio, PL

    2012-01-01

    Structure of High-Resolution NMR Spectra provides the principles, theories, and mathematical and physical concepts of high-resolution nuclear magnetic resonance spectra.The book presents the elementary theory of magnetic resonance; the quantum mechanical theory of angular momentum; the general theory of steady state spectra; and multiple quantum transitions, double resonance and spin echo experiments.Physicists, chemists, and researchers will find the book a valuable reference text.

  1. Relation between frequency of seismic wave and resolution of tomography; Danseiha tomography kaiseki ni okeru shuhasu to bunkaino no kankei

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, M; Watanabe, T; Ashida, Y; Sassa, K [Kyoto University, Kyoto (Japan). Faculty of Engineering

    1997-05-27

    With regard to the elastic wave exploration, discussions have been given on the relationship between frequency and resolution in P-wave velocity tomography using the initial travel time. The discussions were carried out by using a new analysis method which incorporates the concept of Fresnel volume into tomography analysis. The following two arrangements were used in the calculation: a cross hole arrangement, in which seismic source and vibration receiving points were arranged so as to surround the three directions of a region extending 250 m in the horizontal direction and 500 m in the vertical direction, and observation is performed between two wells, and a permeation VSP arrangement in which the seismic source is installed on the ground surface and receiving points installed in wells. Restructuring was performed on the velocity structure by using a total of 819 observation travel times. This method has derived results of the restructuring according to frequencies of the seismic source used for the exploration. The resolution shown in the result of the restructuring has become higher as elastic waves with higher frequency are used, and the size of the structure identified from the restructuring result has decreased. This fact reveals that sufficient considerations must be given on frequencies of elastic waves used according to size of objects to be explored. 4 refs., 4 figs.

  2. High tracking resolution detectors. Final Technical Report

    International Nuclear Information System (INIS)

    Vasile, Stefan; Li, Zheng

    2010-01-01

    High-resolution tracking detectors based on Active Pixel Sensor (APS) have been valuable tools in Nuclear Physics and High-Energy Physics research, and have contributed to major discoveries. Their integration time, radiation length and readout rate is a limiting factor for the planed luminosity upgrades in nuclear and high-energy physics collider-based experiments. The goal of this program was to demonstrate and develop high-gain, high-resolution tracking detector arrays with faster readout, and shorter radiation length than APS arrays. These arrays may operate as direct charged particle detectors or as readouts of high resolution scintillating fiber arrays. During this program, we developed in CMOS large, high-resolution pixel sensor arrays with integrated readout, and reset at pixel level. Their intrinsic gain, high immunity to surface and moisture damage, will allow operating these detectors with minimal packaging/passivation requirements and will result in radiation length superior to APS. In Phase I, we designed and fabricated arrays with calorimetric output capable of sub-pixel resolution and sub-microsecond readout rate. The technical effort was dedicated to detector and readout structure development, performance verification, as well as to radiation damage and damage annealing.

  3. New DOI identification approach for high-resolution PET detectors

    International Nuclear Information System (INIS)

    Choghadi, Amin; Takahashi, Hiroyuki; Shimazoe, Kenji

    2016-01-01

    Depth-of-interaction (DOI) Identification in positron emission tomography (PET) detectors is getting importance as it improves spatial resolution in both conventional and time-of-flight (TOF) PET, and coincidence time resolution (CTR) in TOF-PET. In both prototypes, spatial resolution is affected by parallax error caused by length of scintillator crystals. This long length also contributes substantial timing uncertainty to the time resolution of TOF-PET. Through DOI identification, both parallax error and the timing uncertainty caused by the length of crystal can be resolved. In this work, a novel approach to estimate DOI was investigated, enjoying the interference of absorbance spectrum of scintillator crystals with their emission spectrum. Because the absorption length is close to zero for shorter wavelengths of crystal emission spectrum, the counts in this range of spectrum highly depend on DOI; that is, higher counts corresponds to deeper interactions. The ratio of counts in this range to the total counts is a good measure to estimate DOI. In order to extract such ratio, two photodetectors for each crystal are used and an optical filter is mounted only on top of one of them. The ratio of filtered output to non-filtered output can be utilized as DOI estimator. For a 2×2×20 mm 3 GAGG:Ce scintillator, 8-mm DOI resolution achieved in our simulations. (author)

  4. High-Resolution Characterization of UMo Alloy Microstructure

    Energy Technology Data Exchange (ETDEWEB)

    Devaraj, Arun [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kovarik, Libor [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Joshi, Vineet V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jana, Saumyadeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Manandhar, Sandeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Arey, Bruce W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lavender, Curt A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-30

    This report highlights the capabilities and procedure for high-resolution characterization of UMo fuels in PNNL. Uranium-molybdenum (UMo) fuel processing steps, from casting to forming final fuel, directly affect the microstructure of the fuel, which in turn dictates the in-reactor performance of the fuel under irradiation. In order to understand the influence of processing on UMo microstructure, microstructure characterization techniques are necessary. Higher-resolution characterization techniques like transmission electron microscopy (TEM) and atom probe tomography (APT) are needed to interrogate the details of the microstructure. The findings from TEM and APT are also directly beneficial for developing predictive multiscale modeling tools that can predict the microstructure as a function of process parameters. This report provides background on focused-ion-beam–based TEM and APT sample preparation, TEM and APT analysis procedures, and the unique information achievable through such advanced characterization capabilities for UMo fuels, from a fuel fabrication capability viewpoint.

  5. Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography

    International Nuclear Information System (INIS)

    Chen Guanghong; Zambelli, Joseph; Li Ke; Bevins, Nicholas; Qi Zhihua

    2011-01-01

    Purpose: The noise variance versus spatial resolution relationship in differential phase contrast (DPC) projection imaging and computed tomography (CT) are derived and compared to conventional absorption-based x-ray projection imaging and CT. Methods: The scaling law for DPC-CT is theoretically derived and subsequently validated with phantom results from an experimental Talbot-Lau interferometer system. Results: For the DPC imaging method, the noise variance in the differential projection images follows the same inverse-square law with spatial resolution as in conventional absorption-based x-ray imaging projections. However, both in theory and experimental results, in DPC-CT the noise variance scales with spatial resolution following an inverse linear relationship with fixed slice thickness. Conclusions: The scaling law in DPC-CT implies a lesser noise, and therefore dose, penalty for moving to higher spatial resolutions when compared to conventional absorption-based CT in order to maintain the same contrast-to-noise ratio.

  6. Imaging actinic keratosis by high-definition optical coherence tomography. Histomorphologic correlation

    DEFF Research Database (Denmark)

    Boone, Marc A L M; Norrenberg, Sarah; Jemec, Gregor B E

    2013-01-01

    With the continued development of non-invasive therapies for actinic keratosis such as PDT and immune therapies, the non-invasive diagnosis and monitoring become increasingly relevant. High-definition optical coherence tomography is a high-resolution imaging tool, with micrometre resolution in both...... transversal and axial directions, enable to visualize individual cells up to a depth of around 570 μm filling the imaging gap between conventional optical coherence tomography and reflectance confocal microscopy. We sought to determine the feasibility of detecting and grading of actinic keratosis...... by this technique using criteria defined for reflectance confocal microscopy compared to histology. In this pilot study, skin lesions of 17 patients with a histologically proven actinic keratosis were imaged by high-definition optical coherence tomography just before excision and images analysed qualitatively...

  7. Ultra-high resolution protein crystallography

    International Nuclear Information System (INIS)

    Takeda, Kazuki; Hirano, Yu; Miki, Kunio

    2010-01-01

    Many protein structures have been determined by X-ray crystallography and deposited with the Protein Data Bank. However, these structures at usual resolution (1.5< d<3.0 A) are insufficient in their precision and quantity for elucidating the molecular mechanism of protein functions directly from structural information. Several studies at ultra-high resolution (d<0.8 A) have been performed with synchrotron radiation in the last decade. The highest resolution of the protein crystals was achieved at 0.54 A resolution for a small protein, crambin. In such high resolution crystals, almost all of hydrogen atoms of proteins and some hydrogen atoms of bound water molecules are experimentally observed. In addition, outer-shell electrons of proteins can be analyzed by the multipole refinement procedure. However, the influence of X-rays should be precisely estimated in order to derive meaningful information from the crystallographic results. In this review, we summarize refinement procedures, current status and perspectives for ultra high resolution protein crystallography. (author)

  8. Exogenous lipoid pneumonia: high-resolution CT findings

    International Nuclear Information System (INIS)

    Lee, J.S.; Song, K.S.; Lim, T.H.; Im, J.G.; Seo, J.B.

    1999-01-01

    The aim of this study was to assess high-resolution computed tomography (HRCT) findings of exogenous lipoid pneumonia. High-resolution computed tomography was obtained in 25 patients with proven exogenous lipoid pneumonia resulting from aspiration of squalene (derived from shark liver oil). Diagnosis was based on biopsy (n = 9), bronchoalveolar lavage (n = 8), or sputum cytology and clinical findings (n = 8). The clinical history of taking squalene was confirmed in all patients. The CT findings were classified into three patterns: diffuse ground-glass opacity, consolidation, and interstitial abnormalities. Distribution of the abnormalities, duration of taking squalene, predisposing factors for aspiration, and route of administration were analyzed. Ten patients showed diffuse ground-glass opacity pattern. Seven of 10 patients had predisposing conditions such as unconsciousness, pharyngeal dysmotility, or motor disturbances, and 6 patients had a recent history of taking large amount of squalene through nasal route. Seven patients who had consolidation pattern had a history of taking squalene for several months and did not have any predisposing factor. All of the 5 patients who had a pattern of interstitial abnormalities had a history of taking squalene longer than 1 year and showed segmental distribution of interstitial thickening with interposing ground-glass opacities. Three patients simultaneously had two different patterns at different lobes of the lung. The HRCT findings of lipoid pneumonia are ground-glass opacities, consolidation, and interstitial abnormalities. These HRCT findings with appropriate inquiries could be useful for diagnosis of exogeneous lipoid pneumonia. (orig.)

  9. Astronomy at high angular resolution a compendium of techniques in the visible and near-infrared

    CERN Document Server

    Hussain, Gaitee; Berger, Jean-Philippe; Schmidtobreick, Linda

    2016-01-01

    This book offers an essential compendium of astronomical high-resolution techniques. Recent years have seen considerable developments in such techniques, which are critical to advances in many areas of astronomy. As reflected in the book, these techniques can be divided into direct methods, interferometry, and reconstruction methods, and can be applied to a huge variety of astrophysical systems, ranging from planets, single stars and binaries to active galactic nuclei, providing angular resolution in the micro- to tens of milliarcsecond scales. Written by experts in their fields, the chapters cover adaptive optics, aperture masking imaging, spectra disentangling, interferometry, lucky imaging, Roche tomography, imaging with interferometry, interferometry of AGN, AGN reverberation mapping, Doppler- and magnetic imaging of stellar surfaces, Doppler tomography, eclipse mapping, Stokes imaging, and stellar tomography. This book is intended to enable a next generation of astronomers to apply high-resolution techni...

  10. Optimisation of time resolution in Positron Emission Tomography dedicated to dose control in hadron-therapy

    International Nuclear Information System (INIS)

    Joly, Baptiste

    2010-01-01

    Hadron-therapy is a tumor treatment technique based on irradiation by ions beams. The dose distribution can be controlled during the treatment by Positron Emission Tomography (PET). Indeed, the nuclear collisions between the incident ions and the target medium produce β + emitters, whose spatial distribution is correlated to the dose distribution. However, this application of PET suffers from a low β + activity, a high parasitic activity, and requires fast reconstruction. The Time-Of-Flight technique appears as a key factor to make the in beam PET technique feasible. This work starts from a front-end concept based on fast digital sampling of the detector signals and digital processing for energy and time extraction. The statistical limitations to time resolution determined by the scintillation process are first examined. An experimental set-up with two scintillation detectors in coincidence is then used to test various algorithms: digital discriminators (leading-edge, constant fraction), and filters (least squares, optimal filter, low-pass interpolating filter). The timing performances of all the algorithms are very similar, except the least squares filter, which is not adapted to the non-stationary noise conditions resulting from the scintillation process. Various scintillator materials and configurations are tested, confirming the importance of light yield, scintillation time constants and photodetector response. An avalanche photodiode detector is tested and used for a multichannel demonstrator, which will be used for in-beam tests. (author)

  11. Geometrical analysis of woven fabric microstructure based on micron-resolution computed tomography data

    Science.gov (United States)

    Krieger, Helga; Seide, Gunnar; Gries, Thomas; Stapleton, Scott E.

    2018-04-01

    The global mechanical properties of textiles such as elasticity and strength, as well as transport properties such as permeability depend strongly on the microstructure of the textile. Textiles are heterogeneous structures with highly anisotropic material properties, including local fiber orientation and local fiber volume fraction. In this paper, an algorithm is presented to generate a virtual 3D-model of a woven fabric architecture with information about the local fiber orientation and the local fiber volume fraction. The geometric data of the woven fabric impregnated with resin was obtained by micron-resolution computed tomography (μCT). The volumetric μCT-scan was discretized into cells and the microstructure of each cell was analyzed and homogenized. Furthermore, the discretized data was used to calculate the local permeability tensors of each cell. An example application of the analyzed data is the simulation of the resin flow through a woven fabric based on the determined local permeability tensors and on Darcy's law. The presented algorithm is an automated and robust method of going from μCT-scans to structural or flow models.

  12. High-Resolution PET Detector. Final report

    International Nuclear Information System (INIS)

    Karp, Joel

    2014-01-01

    The objective of this project was to develop an understanding of the limits of performance for a high resolution PET detector using an approach based on continuous scintillation crystals rather than pixelated crystals. The overall goal was to design a high-resolution detector, which requires both high spatial resolution and high sensitivity for 511 keV gammas. Continuous scintillation detectors (Anger cameras) have been used extensively for both single-photon and PET scanners, however, these instruments were based on NaI(Tl) scintillators using relatively large, individual photo-multipliers. In this project we investigated the potential of this type of detector technology to achieve higher spatial resolution through the use of improved scintillator materials and photo-sensors, and modification of the detector surface to optimize the light response function.We achieved an average spatial resolution of 3-mm for a 25-mm thick, LYSO continuous detector using a maximum likelihood position algorithm and shallow slots cut into the entrance surface

  13. A high resolution portable spectroscopy system

    International Nuclear Information System (INIS)

    Kulkarni, C.P.; Vaidya, P.P.; Paulson, M.; Bhatnagar, P.V.; Pande, S.S.; Padmini, S.

    2003-01-01

    Full text: This paper describes the system details of a High Resolution Portable Spectroscopy System (HRPSS) developed at Electronics Division, BARC. The system can be used for laboratory class, high-resolution nuclear spectroscopy applications. The HRPSS consists of a specially designed compact NIM bin, with built-in power supplies, accommodating a low power, high resolution MCA, and on-board embedded computer for spectrum building and communication. A NIM based spectroscopy amplifier and a HV module for detector bias are integrated (plug-in) in the bin. The system communicates with a host PC via a serial link. Along-with a laptop PC, and a portable HP-Ge detector, the HRPSS offers a laboratory class performance for portable applications

  14. High-resolution multi-slice PET

    International Nuclear Information System (INIS)

    Yasillo, N.J.; Chintu Chen; Ordonez, C.E.; Kapp, O.H.; Sosnowski, J.; Beck, R.N.

    1992-01-01

    This report evaluates the progress to test the feasibility and to initiate the design of a high resolution multi-slice PET system. The following specific areas were evaluated: detector development and testing; electronics configuration and design; mechanical design; and system simulation. The design and construction of a multiple-slice, high-resolution positron tomograph will provide substantial improvements in the accuracy and reproducibility of measurements of the distribution of activity concentrations in the brain. The range of functional brain research and our understanding of local brain function will be greatly extended when the development of this instrumentation is completed

  15. High resolution neutron spectroscopy for helium isotopes

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; Klages, H.O.; Schmalz, G.; Haesner, B.H.; Kecskemeti, J.; Schwarz, P.; Wilczynski, J.

    1992-01-01

    A high resolution fast neutron time-of-flight spectrometer is described, neutron time-of-flight spectra are taken using a specially designed TDC in connection to an on-line computer. The high time-of-flight resolution of 5 ps/m enabled the study of the total cross section of 4 He for neutrons near the 3/2 + resonance in the 5 He nucleus. The resonance parameters were determined by a single level Breit-Winger fit to the data. (orig.)

  16. SUPER-RESOLUTION ULTRASOUND TOMOGRAPHY: A PRELIMINARY STUDY WITH A RING ARRAY

    Energy Technology Data Exchange (ETDEWEB)

    HUANG, LIANJIE [Los Alamos National Laboratory; SIMONETTI, FRANCESCO [NON LANL; DURIC, NEBOJSA [NON LANL; RAMA, OLSI [NON LANL

    2007-01-18

    Ultrasound tomography attempts to retrieve the structure of an objective by exploiting the interaction of acoustic waves with the object. A fundamental limit of ultrasound tomography is that features cannot be resolved if they are spaced less than {lambda}/2 apart, where {lambda} is wavelength of the probing wave, regardless of the degree of accuracy of the measurements. Therefore, since the attenuation of the probing wave with propagation distance increases as {lambda} decreases, resolution has to be traded against imaging depth. Recently, it has been shown that the {lambda}/2 limit is a consequence of the Born approximation (implicit in the imaging algorithms currently employed) which neglects the distortion of the probing wavefield as it travels through the medium to be imaged. On the other hand, such a distortion, which is due to the multiple scattering phenomenon, can encode unlimited resolution in the radiating component of the scattered field. Previously, a resolution better than {lambda}/3 has been reported in these proceedings [F. Simonetti, pp. 126 (2006)] in the case of elastic wave probing. In this paper, they demonstrate experimentally a resolution better than {lambda}/4 for objects immersed in a water bth probed by means of a ring array which excites and detects pressure waves in a full view configuration.

  17. Smartphone microendoscopy for high resolution fluorescence imaging

    Directory of Open Access Journals (Sweden)

    Xiangqian Hong

    2016-09-01

    Full Text Available High resolution optical endoscopes are increasingly used in diagnosis of various medical conditions of internal organs, such as the cervix and gastrointestinal (GI tracts, but they are too expensive for use in resource-poor settings. On the other hand, smartphones with high resolution cameras and Internet access have become more affordable, enabling them to diffuse into most rural areas and developing countries in the past decade. In this paper, we describe a smartphone microendoscope that can take fluorescence images with a spatial resolution of 3.1 μm. Images collected from ex vivo, in vitro and in vivo samples using the device are also presented. The compact and cost-effective smartphone microendoscope may be envisaged as a powerful tool for detecting pre-cancerous lesions of internal organs in low and middle-income countries (LMICs.

  18. Advances in broad bandwidth light sources for ultrahigh resolution optical coherence tomography

    International Nuclear Information System (INIS)

    Unterhuber, A; Povazay, B; Bizheva, K; Hermann, B; Sattmann, H; Stingl, A; Le, T; Seefeld, M; Menzel, R; Preusser, M; Budka, H; Schubert, Ch; Reitsamer, H; Ahnelt, P K; Morgan, J E; Cowey, A; Drexler, W

    2004-01-01

    Novel ultra-broad bandwidth light sources enabling unprecedented sub-2 μm axial resolution over the 400 nm-1700 nm wavelength range have been developed and evaluated with respect to their feasibility for clinical ultrahigh resolution optical coherence tomography (UHR OCT) applications. The state-of-the-art light sources described here include a compact Kerr lens mode locked Ti:sapphire laser (λ c = 785 nm, Δλ = 260 nm, P out = 50 mW) and different nonlinear fibre-based light sources with spectral bandwidths (at full width at half maximum) up to 350 nm at λ c = 1130 nm and 470 nm at λ c = 1375 nm. In vitro UHR OCT imaging is demonstrated at multiple wavelengths in human cancer cells, animal ganglion cells as well as in neuropathologic and ophthalmic biopsies in order to compare and optimize UHR OCT image contrast, resolution and penetration depth

  19. High-resolution CT findings in Streptococcus milleri pulmonary infection

    International Nuclear Information System (INIS)

    Okada, F.; Ono, A.; Ando, Y.; Nakayama, T.; Ishii, H.; Hiramatsu, K.; Sato, H.; Kira, A.; Otabe, M.; Mori, H.

    2013-01-01

    Aim: To assess pulmonary high-resolution computed tomography (CT) findings in patients with acute Streptococcus milleri pulmonary infection. Materials and methods: Sixty consecutive patients with acute S. milleri pneumonia who had undergone high-resolution CT chest examinations between January 2004 and March 2010 were retrospectively identified. Twenty-seven patients with concurrent infections were excluded. The final study group comprised 33 patients (25 men, 8 women; aged 20–88 years, mean 63.1 years) with S. milleri infection. The patients' clinical findings were assessed. Parenchymal abnormalities, enlarged lymph nodes, and pleural effusion were evaluated on high-resolution CT. Results: Underlying conditions included malignancy (n = 15), a smoking habit (n = 11), and diabetes mellitus (n = 8). CT images of all patients showed abnormal findings, including ground-glass opacity (n = 24), bronchial wall thickening (n = 23), consolidation (n = 17), and cavities (n = 7). Pleural effusion was found in 18 patients, and complex pleural effusions were found in seven patients. Conclusion: Pulmonary infection caused by S. milleri was observed mostly in male patients with underlying conditions such as malignancy or a smoking habit. The CT findings in patients with S. milleri consisted mainly of ground-glass opacity, bronchial wall thickening, pleural effusions, and cavities

  20. High resolution Neutron and Synchrotron Powder Diffraction

    International Nuclear Information System (INIS)

    Hewat, A.W.

    1986-01-01

    The use of high-resolution powder diffraction has grown rapidly in the past years, with the development of Rietveld (1967) methods of data analysis and new high-resolution diffractometers and multidetectors. The number of publications in this area has increased from a handful per year until 1973 to 150 per year in 1984, with a ten-year total of over 1000. These papers cover a wide area of solid state-chemistry, physics and materials science, and have been grouped under 20 subject headings, ranging from catalysts to zeolites, and from battery electrode materials to pre-stressed superconducting wires. In 1985 two new high-resolution diffractometers are being commissioned, one at the SNS laboratory near Oxford, and one at the ILL in Grenoble. In different ways these machines represent perhaps the ultimate that can be achieved with neutrons and will permit refinement of complex structures with about 250 parameters and unit cell volumes of about 2500 Angstrom/sp3/. The new European Synchotron Facility will complement the Grenoble neutron diffractometers, and extend the role of high-resolution powder diffraction to the direct solution of crystal structures, pioneered in Sweden

  1. Classification of high resolution satellite images

    OpenAIRE

    Karlsson, Anders

    2003-01-01

    In this thesis the Support Vector Machine (SVM)is applied on classification of high resolution satellite images. Sveral different measures for classification, including texture mesasures, 1st order statistics, and simple contextual information were evaluated. Additionnally, the image was segmented, using an enhanced watershed method, in order to improve the classification accuracy.

  2. High-resolution clean-sc

    NARCIS (Netherlands)

    Sijtsma, P.; Snellen, M.

    2016-01-01

    In this paper a high-resolution extension of CLEAN-SC is proposed: HR-CLEAN-SC. Where CLEAN-SC uses peak sources in “dirty maps” to define so-called source components, HR-CLEAN-SC takes advantage of the fact that source components can likewise be derived from points at some distance from the peak,

  3. A High-Resolution Stopwatch for Cents

    Science.gov (United States)

    Gingl, Z.; Kopasz, K.

    2011-01-01

    A very low-cost, easy-to-make stopwatch is presented to support various experiments in mechanics. The high-resolution stopwatch is based on two photodetectors connected directly to the microphone input of a sound card. Dedicated free open-source software has been developed and made available to download. The efficiency is demonstrated by a free…

  4. 'Big Bang' tomography as a new route to atomic-resolution electron tomography.

    Science.gov (United States)

    Van Dyck, Dirk; Jinschek, Joerg R; Chen, Fu-Rong

    2012-06-13

    Until now it has not been possible to image at atomic resolution using classical electron tomographic methods, except when the target is a perfectly crystalline nano-object imaged along a few zone axes. The main reasons are that mechanical tilting in an electron microscope with sub-ångström precision over a very large angular range is difficult, that many real-life objects such as dielectric layers in microelectronic devices impose geometrical constraints and that many radiation-sensitive objects such as proteins limit the total electron dose. Hence, there is a need for a new tomographic scheme that is able to deduce three-dimensional information from only one or a few projections. Here we present an electron tomographic method that can be used to determine, from only one viewing direction and with sub-ångström precision, both the position of individual atoms in the plane of observation and their vertical position. The concept is based on the fact that an experimentally reconstructed exit wave consists of the superposition of the spherical waves that have been scattered by the individual atoms of the object. Furthermore, the phase of a Fourier component of a spherical wave increases with the distance of propagation at a known 'phase speed'. If we assume that an atom is a point-like object, the relationship between the phase and the phase speed of each Fourier component is linear, and the distance between the atom and the plane of observation can therefore be determined by linear fitting. This picture has similarities with Big Bang cosmology, in which the Universe expands from a point-like origin such that the distance of any galaxy from the origin is linearly proportional to the speed at which it moves away from the origin (Hubble expansion). The proof of concept of the method has been demonstrated experimentally for graphene with a two-layer structure and it will work optimally for similar layered materials, such as boron nitride and molybdenum disulphide.

  5. Constructing a WISE High Resolution Galaxy Atlas

    Science.gov (United States)

    Jarrett, T. H.; Masci, F.; Tsai, C. W.; Petty, S.; Cluver, M.; Assef, Roberto J.; Benford, D.; Blain, A.; Bridge, C.; Donoso, E.; hide

    2012-01-01

    After eight months of continuous observations, the Wide-field Infrared Survey Explorer (WISE) mapped the entire sky at 3.4 micron, 4.6 micron, 12 micron, and 22 micron. We have begun a dedicated WISE High Resolution Galaxy Atlas project to fully characterize large, nearby galaxies and produce a legacy image atlas and source catalog. Here we summarize the deconvolution techniques used to significantly improve the spatial resolution of WISE imaging, specifically designed to study the internal anatomy of nearby galaxies. As a case study, we present results for the galaxy NGC 1566, comparing the WISE enhanced-resolution image processing to that of Spitzer, Galaxy Evolution Explorer, and ground-based imaging. This is the first paper in a two-part series; results for a larger sample of nearby galaxies are presented in the second paper.

  6. High resolution imaging of boron carbide microstructures

    International Nuclear Information System (INIS)

    MacKinnon, I.D.R.; Aselage, T.; Van Deusen, S.B.

    1986-01-01

    Two samples of boron carbide have been examined using high resolution transmission electron microscopy (HRTEM). A hot-pressed B 13 C 2 sample shows a high density of variable width twins normal to (10*1). Subtle shifts or offsets of lattice fringes along the twin plane and normal to approx.(10*5) were also observed. A B 4 C powder showed little evidence of stacking disorder in crystalline regions

  7. High contrast computed tomography with synchrotron radiation

    Science.gov (United States)

    Itai, Yuji; Takeda, Tohoru; Akatsuka, Takao; Maeda, Tomokazu; Hyodo, Kazuyuki; Uchida, Akira; Yuasa, Tetsuya; Kazama, Masahiro; Wu, Jin; Ando, Masami

    1995-02-01

    This article describes a new monochromatic x-ray CT system using synchrotron radiation with applications in biomedical diagnosis which is currently under development. The system is designed to provide clear images and to detect contrast materials at low concentration for the quantitative functional evaluation of organs in correspondence with their anatomical structures. In this system, with x-ray energy changing from 30 to 52 keV, images can be obtained to detect various contrast materials (iodine, barium, and gadolinium), and K-edge energy subtraction is applied. Herein, the features of the new system designed to enhance the advantages of SR are reported. With the introduction of a double-crystal monochromator, the high-order x-ray contamination is eliminated. The newly designed CCD detector with a wide dynamic range of 60 000:1 has a spatial resolution of 200 μm. The resulting image quality, which is expected to show improved contrast and spatial resolution, is currently under investigation.

  8. Toward Rapid Unattended X-ray Tomography of Large Planar Samples at 50-nm Resolution

    International Nuclear Information System (INIS)

    Rudati, J.; Tkachuk, A.; Gelb, J.; Hsu, G.; Feng, Y.; Pastrick, R.; Lyon, A.; Trapp, D.; Beetz, T.; Chen, S.; Hornberger, B.; Seshadri, S.; Kamath, S.; Zeng, X.; Feser, M.; Yun, W.; Pianetta, P.; Andrews, J.; Brennan, S.; Chu, Y. S.

    2009-01-01

    X-ray tomography at sub-50 nm resolution of small areas (∼15 μmx15 μm) are routinely performed with both laboratory and synchrotron sources. Optics and detectors for laboratory systems have been optimized to approach the theoretical efficiency limit. Limited by the availability of relatively low-brightness laboratory X-ray sources, exposure times for 3-D data sets at 50 nm resolution are still many hours up to a full day. However, for bright synchrotron sources, the use of these optimized imaging systems results in extremely short exposure times, approaching live-camera speeds at the Advanced Photon Source at Argonne National Laboratory near Chicago in the US These speeds make it possible to acquire a full tomographic dataset at 50 nm resolution in less than a minute of true X-ray exposure time. However, limits in the control and positioning system lead to large overhead that results in typical exposure times of ∼15 min currently.We present our work on the reduction and elimination of system overhead and toward complete automation of the data acquisition process. The enhancements underway are primarily to boost the scanning rate, sample positioning speed, and illumination homogeneity to performance levels necessary for unattended tomography of large areas (many mm 2 in size). We present first results on this ongoing project.

  9. Study on the performance of large area MRPC with high position resolution

    Energy Technology Data Exchange (ETDEWEB)

    Yue Qian, E-mail: yueq@mail.tsinghua.edu.cn [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education (China); Wu Yucheng; Li Yuanjing; Ye Jin; Cheng Jianping; Wang Yi; Li Jin [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education (China)

    2012-01-01

    Multi-gap resistive plate chamber (MRPC), which is mostly developed in high energy physics domain with excellent time resolution, is also highlighted in imaging applications. A set of 50 cm Multiplication-Sign 50 cm large area MRPC with high position resolution was successfully developed by our group and different experiments have been done to test its performances. Cosmic ray muons were used to do the test and proper high voltage and working gas were chosen. Data analysis indicates its good detection efficiency and good position resolution, which encourages further study of its application in RPC-PET and muon tomography.

  10. High resolution SETI: Experiences and prospects

    Science.gov (United States)

    Horowitz, Paul; Clubok, Ken

    Megachannel spectroscopy with sub-Hertz resolution constitutes an attractive strategy for a microwave search for extraterrestrial intelligence (SETI), assuming the transmission of a narrowband radiofrequency beacon. Such resolution matches the properties of the interstellar medium, and the necessary Doppler corrections provide a high degree of interference rejection. We have constructed a frequency-agile receiver with an FFT-based 8 megachannel digital spectrum analyzer, on-line signal recognition, and multithreshold archiving. We are using it to conduct a meridian transit search of the northern sky at the Harvard-Smithsonian 26-m antenna, with a second identical system scheduled to begin observations in Argentina this month. Successive 400 kHz spectra, at 0.05 Hz resolution, are searched for features characteristic of an intentional narrowband beacon transmission. These spectra are centered on guessable frequencies (such as λ21 cm), referenced successively to the local standard of rest, the galactic barycenter, and the cosmic blackbody rest frame. This search has rejected interference admirably, but is greatly limited both in total frequency coverage and sensitivity to signals other than carriers. We summarize five years of high resolution SETI at Harvard, in the context of answering the questions "How useful is narrowband SETI, how serious are its limitations, what can be done to circumvent them, and in what direction should SETI evolve?" Increasingly powerful signal processing hardware, combined with ever-higher memory densities, are particularly relevant, permitting the construction of compact and affordable gigachannel spectrum analyzers covering hundreds of megahertz of instantaneous bandwidth.

  11. Idiopathic pulmonary fibrosis and collagen vascular diseases - high resolution CT findings

    International Nuclear Information System (INIS)

    Ferreira Neto, Armando Leao; Mogami, Roberto; Marchiori, Edson; Capone, Domenico

    1996-01-01

    The aspects of the thorax high-resolution computed tomography of 15 patients with idiopathic pulmonary fibrosis and 11 patients with collagen vascular diseases are described and characterized mainly by the presence of reticular lesions with little cysts predominantly in the periphery and lower lobes. They may be associated with ground-glass lesions that, as usual, means areas of alveolitis. (author)

  12. Vascular channels in metacarpophalangeal joints : a comparative histologic and high-resolution imaging study

    NARCIS (Netherlands)

    Scharmga, A.; Keller, K.K.; Peters, M.; van Tubergen, A.; van den Bergh, J.P.W.; van Rietbergen, B.; Weijers, R.; Loeffen, D.; Hauge, E.M.; Geusens, P.P.M.M.

    2017-01-01

    We evaluated whether cortical interruptions classified as vascular channel (VC) on high-resolution peripheral quantitative computed tomography (HR-pQCT) could be confirmed by histology. We subsequently evaluated the image characteristics of histologically identified VCs on matched single and

  13. Maximum likelihood positioning algorithm for high-resolution PET scanners

    International Nuclear Information System (INIS)

    Gross-Weege, Nicolas; Schug, David; Hallen, Patrick; Schulz, Volkmar

    2016-01-01

    Purpose: In high-resolution positron emission tomography (PET), lightsharing elements are incorporated into typical detector stacks to read out scintillator arrays in which one scintillator element (crystal) is smaller than the size of the readout channel. In order to identify the hit crystal by means of the measured light distribution, a positioning algorithm is required. One commonly applied positioning algorithm uses the center of gravity (COG) of the measured light distribution. The COG algorithm is limited in spatial resolution by noise and intercrystal Compton scatter. The purpose of this work is to develop a positioning algorithm which overcomes this limitation. Methods: The authors present a maximum likelihood (ML) algorithm which compares a set of expected light distributions given by probability density functions (PDFs) with the measured light distribution. Instead of modeling the PDFs by using an analytical model, the PDFs of the proposed ML algorithm are generated assuming a single-gamma-interaction model from measured data. The algorithm was evaluated with a hot-rod phantom measurement acquired with the preclinical HYPERION II D PET scanner. In order to assess the performance with respect to sensitivity, energy resolution, and image quality, the ML algorithm was compared to a COG algorithm which calculates the COG from a restricted set of channels. The authors studied the energy resolution of the ML and the COG algorithm regarding incomplete light distributions (missing channel information caused by detector dead time). Furthermore, the authors investigated the effects of using a filter based on the likelihood values on sensitivity, energy resolution, and image quality. Results: A sensitivity gain of up to 19% was demonstrated in comparison to the COG algorithm for the selected operation parameters. Energy resolution and image quality were on a similar level for both algorithms. Additionally, the authors demonstrated that the performance of the ML

  14. Tuberculose pulmonar: achados na tomografia computadorizada de alta resolução do tórax em pacientes com doença em atividade comprovada bacteriologicamente Pulmonary tuberculosis: findings on high resolution computerized tomography of active disease on patients with bacteriological confirmation

    Directory of Open Access Journals (Sweden)

    CRISTIANE ALÓ CAMPOS

    2002-01-01

    Full Text Available Objetivo: Descrever os achados em pacientes com tuberculose pulmonar em atividade na tomografia computadorizada de alta resolução e o padrão de distribuição das lesões pelo parênquima pulmonar. Casuística e método: Foram analisadas retrospectivamente as tomografias de alta resolução de 42 pacientes com diagnóstico bacteriológico de tuberculose pulmonar ou forte suspeita clínica, com posterior confirmação bacteriológica. Resultados: Os principais sinais sugestivos de atividade encontrados foram nódulos do espaço aéreo (83%, nódulos centrolobulares (74%, aspecto de árvore em brotamento (67%, cavitações (67%, espessamento das paredes brônquicas (55%, consolidações (48%, opacidade em vidro fosco (21%, e espessamento do interstício pulmonar (9%. Conclusão: A tomografia computadorizada de alta resolução do tórax pode sugerir fortemente atividade da doença, sendo particularmente útil nos pacientes com baciloscopias negativas e/ou radiografias indeterminadas, permitindo a instituição de tratamento adequado, antes mesmo do crescimento da micobactéria em meio de cultura.Background: The aim of this study was to describe the signs of active tuberculosis in patients submitted to high resolution computerized tomography and the distribution of lesions along the pulmonary parenchyma. Material and methods: The high resolution CTs performed on 42 patients with tuberculosis either bacteriologically diagnosed or clinical suspected and later confirmed by bacteriological tests were studied. Results: The signs of disease activity observed were airspace nodule (83%, centrilobular nodule (74%, tree-in-bud pattern (67%, cavitations (67%, bronchial thickening (55%, parenchymal consolidations (48%, ground glass opacity (21% and thickening of the inter and intralobular septa (9%. Conclusion: High resolution computed tomography can be strongly suggestive of disease activity, is particularly helpful in patients with negative smear and

  15. High resolution NMR theory and chemical applications

    CERN Document Server

    Becker, Edwin D

    2012-01-01

    High Resolution NMR: Theory and Chemical Applications discusses the principles and theory of nuclear magnetic resonance and how this concept is used in the chemical sciences. This book is written at an intermediate level, with mathematics used to augment verbal descriptions of the phenomena. This text pays attention to developing and interrelating four approaches - the steady state energy levels, the rotating vector picture, the density matrix, and the product operator formalism. The style of this book is based on the assumption that the reader has an acquaintance with the general principles of quantum mechanics, but no extensive background in quantum theory or proficiency in mathematics is required. This book begins with a description of the basic physics, together with a brief account of the historical development of the field. It looks at the study of NMR in liquids, including high resolution NMR in the solid state and the principles of NMR imaging and localized spectroscopy. This book is intended to assis...

  16. High resolution NMR theory and chemical applications

    CERN Document Server

    Becker, Edwin D

    1999-01-01

    High Resolution NMR provides a broad treatment of the principles and theory of nuclear magnetic resonance (NMR) as it is used in the chemical sciences. It is written at an "intermediate" level, with mathematics used to augment, rather than replace, clear verbal descriptions of the phenomena. The book is intended to allow a graduate student, advanced undergraduate, or researcher to understand NMR at a fundamental level, and to see illustrations of the applications of NMR to the determination of the structure of small organic molecules and macromolecules, including proteins. Emphasis is on the study of NMR in liquids, but the treatment also includes high resolution NMR in the solid state and the principles of NMR imaging and localized spectroscopy. Careful attention is given to developing and interrelating four approaches - steady state energy levels, the rotating vector picture, the density matrix, and the product operator formalism. The presentation is based on the assumption that the reader has an acquaintan...

  17. High-resolution flurescence spectroscopy in immunoanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Grubor, Nenad M. [Iowa State Univ., Ames, IA (United States)

    2005-01-01

    The work presented in this dissertation combines highly sensitive and selective fluorescence line-narrowing spectroscopy (FLNS) detection with various modes of immunoanalytical techniques. It has been shown that FLNS is capable of directly probing molecules immunocomplexed with antibodies, eliminating analytical ambiguities that may arise from interferences that accompany traditional immunochemical techniques. Moreover, the utilization of highly cross-reactive antibodies for highly specific analyte determination has been demonstrated. Finally, they demonstrate the first example of the spectral resolution of diastereomeric analytes based on their interaction with a cross-reactive antibody.

  18. High-Resolution MRI in Rectal Cancer

    International Nuclear Information System (INIS)

    Dieguez, Adriana

    2010-01-01

    High-resolution MRI is the best method of assessing the relation of the rectal tumor with the potential circumferential resection margin (CRM). Therefore it is currently considered the method of choice for local staging of rectal cancer. The primary surgery of rectal cancer is total mesorectal excision (TME), which plane of dissection is formed by the mesorectal fascia surrounding mesorectal fat and rectum. This fascia will determine the circumferential margin of resection. At the same time, high resolution MRI allows adequate pre-operative identification of important prognostic risk factors, improving the selection and indication of therapy for each patient. This information includes, besides the circumferential margin of resection, tumor and lymph node staging, extramural vascular invasion and the description of lower rectal tumors. All these should be described in detail in the report, being part of the discussion in the multidisciplinary team, the place where the decisions involving the patient with rectal cancer will take place. The aim of this study is to provide the information necessary to understand the use of high resolution MRI in the identification of prognostic risk factors in rectal cancer. The technical requirements and standardized report for this study will be describe, as well as the anatomical landmarks of importance for the total mesorectal excision (TME), as we have said is the surgery of choice for rectal cancer. (authors) [es

  19. Improvement of resolution in full-view linear-array photoacoustic computed tomography using a novel adaptive weighting method

    Science.gov (United States)

    Omidi, Parsa; Diop, Mamadou; Carson, Jeffrey; Nasiriavanaki, Mohammadreza

    2017-03-01

    Linear-array-based photoacoustic computed tomography is a popular methodology for deep and high resolution imaging. However, issues such as phase aberration, side-lobe effects, and propagation limitations deteriorate the resolution. The effect of phase aberration due to acoustic attenuation and constant assumption of the speed of sound (SoS) can be reduced by applying an adaptive weighting method such as the coherence factor (CF). Utilizing an adaptive beamforming algorithm such as the minimum variance (MV) can improve the resolution at the focal point by eliminating the side-lobes. Moreover, invisibility of directional objects emitting parallel to the detection plane, such as vessels and other absorbing structures stretched in the direction perpendicular to the detection plane can degrade resolution. In this study, we propose a full-view array level weighting algorithm in which different weighs are assigned to different positions of the linear array based on an orientation algorithm which uses the histogram of oriented gradient (HOG). Simulation results obtained from a synthetic phantom show the superior performance of the proposed method over the existing reconstruction methods.

  20. Complicações pulmonares após uso de crack: achados na tomografia computadorizada de alta resolução do tórax Pulmonary complications of crack cocaine use: high-resolution computed tomography of the chest

    Directory of Open Access Journals (Sweden)

    Alexandre Mançano

    2008-05-01

    Full Text Available Relatamos os achados na tomografia computadorizada de alta resolução de um paciente que, após uso de cocaína fumada (crack, desenvolveu quadro de hemoptise, dispnéia e dor torácica súbitas. As radiografias de tórax mostravam consolidações predominando em lobos superiores. A tomografia de alta resolução evidenciava opacidades em vidro fosco, consolidações e nódulos do espaço aéreo. Nova tomografia de controle, após suspensão da droga e uso de corticóides, mostrou regressão parcial das lesões e aparecimento de escavações. A correlação entre os achados clínicos, laboratoriais e de imagem permitiu o diagnóstico de "pulmão de crack".Here, we report high-resolution computed tomography (HRCT findings in a patient who developed sudden hemoptysis, dyspnea and chest pain after smoking crack cocaine. Chest X-rays showed consolidations, primarily in the upper lobes, and HRCT scans showed ground glass attenuation opacities, consolidations and air-space nodules. A follow-up CT, after drug use discontinuation and administration of corticosteroids, showed partial resolution of pulmonary lesions and the appearance of cavitations. Clinical, imaging and laboratory findings led to a diagnosis of 'crack lung'.

  1. USGS High Resolution Orthoimagery Collection - Historical - National Geospatial Data Asset (NGDA) High Resolution Orthoimagery

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — USGS high resolution orthorectified images from The National Map combine the image characteristics of an aerial photograph with the geometric qualities of a map. An...

  2. Meniscus tears of the knee: Postarthrogram high resolution CT

    International Nuclear Information System (INIS)

    Kim, Jae Hyoung; Do, Young Soo; You, Jin Jong; Gong, Jae Chul; Kim, Hyung Jin; Chung, Sung Hoon

    1990-01-01

    Thirty-eight knees with clinically suspected meniscal tears were examined with high resolution computed tomography(HRCT) immediately following double contrast arthrography. All subsequently underwent arthroscopy. The findings of postarthrogram HRCT and arthroscopy were compared to evaluated the usefulness of postarthrogram HRCT in diagnosis of the meniscal tears. The sensitivity, specificity and accuracy of HRCT were 96.2%. 83.3% and 92.1% respectively. The anatomic details of the meniscal tears were clearly visible on the HRCT scans. Sagittal and coronal reformation views well visualized the horizontal tears and the relationship of torn meniscal fragments, and well differential the peripheral tears from the synovial recess. Our result indicate that postarthrogram HRCT not only is a sensitive and effective method for the detection and characterization of the meniscal tears, but also provides arthroscopists with the appropriate surgical plans

  3. High energy near- and far-field ptychographic tomography at the ESRF

    Science.gov (United States)

    da Silva, Julio C.; Haubrich, Jan; Requena, Guillermo; Hubert, Maxime; Pacureanu, Alexandra; Bloch, Leonid; Yang, Yang; Cloetens, Peter

    2017-09-01

    In high-resolution tomography, one needs high-resolved projections in order to reconstruct a high-quality 3D map of a sample. X-ray ptychography is a robust technique which can provide such high-resolution 2D projections taking advantage of coherent X-rays. This technique was used in the far-field regime for a fair amount of time, but it can now also be implemented in the near-field regime. In both regimes, the technique enables not only high-resolution imaging, but also high sensitivity to the electron density of the sample. The combination with tomography makes 3D imaging possible via ptychographic X-ray computed tomography (PXCT), which can provide a 3D map of the complex-valued refractive index of the sample. The extension of PXCT to X-ray energies above 15 keV is challenging, but it can allow the imaging of object opaque to lower energy. We present here the implementation and developments of high-energy near- and far-field PXCT at the ESRF.

  4. High-resolution 3D imaging of polymerized photonic crystals by lab-based x-ray nanotomography with 50-nm resolution

    Science.gov (United States)

    Yin, Leilei; Chen, Ying-Chieh; Gelb, Jeff; Stevenson, Darren M.; Braun, Paul A.

    2010-09-01

    High resolution x-ray computed tomography is a powerful non-destructive 3-D imaging method. It can offer superior resolution on objects that are opaque or low contrast for optical microscopy. Synchrotron based x-ray computed tomography systems have been available for scientific research, but remain difficult to access for broader users. This work introduces a lab-based high-resolution x-ray nanotomography system with 50nm resolution in absorption and Zernike phase contrast modes. Using this system, we have demonstrated high quality 3-D images of polymerized photonic crystals which have been analyzed for band gap structures. The isotropic volumetric data shows excellent consistency with other characterization results.

  5. Moderate resolution spectrophotometry of high redshift quasars

    Science.gov (United States)

    Schneider, Donald P.; Schmidt, Maarten; Gunn, James E.

    1991-01-01

    A uniform set of photometry and high signal-to-noise moderate resolution spectroscopy of 33 quasars with redshifts larger than 3.1 is presented. The sample consists of 17 newly discovered quasars (two with redshifts in excess of 4.4) and 16 sources drawn from the literature. The objects in this sample have r magnitudes between 17.4 and 21.4; their luminosities range from -28.8 to -24.9. Three of the 33 objects are broad absorption line quasars. A number of possible high redshift damped Ly-alpha systems were found.

  6. SPIRAL2/DESIR high resolution mass separator

    Energy Technology Data Exchange (ETDEWEB)

    Kurtukian-Nieto, T., E-mail: kurtukia@cenbg.in2p3.fr [Centre d’Études Nucléaires de Bordeaux Gradignan, Université Bordeaux 1-CNRS/IN2P3, BP 120, F-33175 Gradignan Cedex (France); Baartman, R. [TRIUMF, 4004 Wesbrook Mall, Vancouver B.C., V6T 2A3 (Canada); Blank, B.; Chiron, T. [Centre d’Études Nucléaires de Bordeaux Gradignan, Université Bordeaux 1-CNRS/IN2P3, BP 120, F-33175 Gradignan Cedex (France); Davids, C. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Delalee, F. [Centre d’Études Nucléaires de Bordeaux Gradignan, Université Bordeaux 1-CNRS/IN2P3, BP 120, F-33175 Gradignan Cedex (France); Duval, M. [GANIL, CEA/DSM-CNRS/IN2P3, Bd Henri Becquerel, BP 55027, F-14076 Caen Cedex 5 (France); El Abbeir, S.; Fournier, A. [Centre d’Études Nucléaires de Bordeaux Gradignan, Université Bordeaux 1-CNRS/IN2P3, BP 120, F-33175 Gradignan Cedex (France); Lunney, D. [CSNSM-IN2P3-CNRS, Université de Paris Sud, F-91405 Orsay (France); Méot, F. [BNL, Upton, Long Island, New York (United States); Serani, L. [Centre d’Études Nucléaires de Bordeaux Gradignan, Université Bordeaux 1-CNRS/IN2P3, BP 120, F-33175 Gradignan Cedex (France); Stodel, M.-H.; Varenne, F. [GANIL, CEA/DSM-CNRS/IN2P3, Bd Henri Becquerel, BP 55027, F-14076 Caen Cedex 5 (France); and others

    2013-12-15

    DESIR is the low-energy part of the SPIRAL2 ISOL facility under construction at GANIL. DESIR includes a high-resolution mass separator (HRS) with a designed resolving power m/Δm of 31,000 for a 1 π-mm-mrad beam emittance, obtained using a high-intensity beam cooling device. The proposed design consists of two 90-degree magnetic dipoles, complemented by electrostatic quadrupoles, sextupoles, and a multipole, arranged in a symmetric configuration to minimize aberrations. A detailed description of the design and results of extensive simulations are given.

  7. An original acquisition chain for the TOHR High Resolution Tomograph

    International Nuclear Information System (INIS)

    Pinot, Laurent

    1999-01-01

    The framework of this work is part of a new approach of emission tomography adapted to small animals. The principle of our tomographic system TOHR (French acronym for High Resolution Tomograph) is based on the use of large solid angle and high resolution focusing collimators each mounted in front of a detection module of high efficiency. With a first-generation acquisition chain we were able to characterize TOHR, however, to take fully advantage of the TOHR possibilities, a completely new acquisition scheme had to be designed. This system, being the main topic of this work, makes use of temporal information. The detection of a particle that entered the detector is translated into temporal logical signals. These signals pass into a time coding circuitry and the coded results are transferred in a digital processor. According to the initial terms of delivery, the developed acquisition chain steers the detection of events dependent on the deposited energy and time of arrival. The latter is done by coincidence measurements. All elements are mounted on a special board included into a PC unit and a dedicated program controls the whole system. First experiments showed up the interest of the new acquisition unit for other application in physics or medical imaging

  8. Toward electron exit wave tomography of amorphous materials at atomic resolution

    Energy Technology Data Exchange (ETDEWEB)

    Borisenko, Konstantin B., E-mail: konstantin.borisenko@materials.ox.ac.uk [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Moldovan, Grigore [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Kirkland, Angus I., E-mail: angus.kirkland@materials.ox.ac.uk [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Van Dyck, Dirk [Department of Physics, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp (Belgium); Tang, Hsin-Yu; Chen, Fu-Rong [Department of Engineering and System Science, National Tsing Hua University, Kuang-Fu Road, 300 Hsinchu, Taiwan (China)

    2012-09-25

    Highlights: Black-Right-Pointing-Pointer We suggest a novel electron exit wave tomography approach to obtain three dimensional atomic structures of amorphous materials. Black-Right-Pointing-Pointer Theoretical tests using a model of amorphous Si doped with Au show that it is feasible to reconstruct both Si and Au atoms positions. Black-Right-Pointing-Pointer Reconstructions of the strongly scattering Au atoms positions appear to be insensitive to typical experimental errors. - Abstract: We suggest to use electron exit wave phase for tomographic reconstruction of structure of Au-doped amorphous Si with atomic resolution. In the present theoretical investigation into the approach it is found that the number of projections and the accuracy of defocus in the focal series restoration are the main factors that contribute to the final resolution. Although resolution is ultimately limited by these factors, phase shifts in the exit wave are sufficient to identify the position of Au atoms in an amorphous Si needle model, even when only 19 projections with defocus error of 4 nm are used. Electron beam damage will probably further limit the resolution of such tomographic reconstructions, however beam damage can be mitigated using lower accelerating voltages.

  9. Processing method for high resolution monochromator

    International Nuclear Information System (INIS)

    Kiriyama, Koji; Mitsui, Takaya

    2006-12-01

    A processing method for high resolution monochromator (HRM) has been developed at Japanese Atomic Energy Agency/Quantum Beam Science Directorate/Synchrotron Radiation Research unit at SPring-8. For manufacturing a HRM, a sophisticated slicing machine and X-ray diffractometer have been installed for shaping a crystal ingot and orienting precisely the surface of a crystal ingot, respectively. The specification of the slicing machine is following; Maximum size of a diamond blade is φ 350mm in diameter, φ 38.1mm in the spindle diameter, and 2mm in thickness. A large crystal such as an ingot with 100mm in diameter, 200mm in length can be cut. Thin crystal samples such as a wafer can be also cut using by another sample holder. Working distance of a main shaft with the direction perpendicular to working table in the machine is 350mm at maximum. Smallest resolution of the main shaft with directions of front-and-back and top-and-bottom are 0.001mm read by a digital encoder. 2mm/min can set for cutting samples in the fo