WorldWideScience

Sample records for high resolution sonography

  1. Usefulness of high-resolution sonography in early diagnosis of rabbit clonorchiasis

    International Nuclear Information System (INIS)

    Lim, Jae Hoon; Choi, Don Gil; Chung, Il Gyu; Phyun, Lae Hyun; Pyeun, Yong Seon; Hong, Sung Tae; Lee, Me Jeong

    1999-01-01

    To determine the role of high-resolution sonography in the early diagnosis of experimentally induced clonorchiasis in rabbits. We performed sonographic examination weekly in 22 lightly-infected rabbits (10 rabbits infected with 10 metacercariae, 6 rabbits infected with 20 metacercariae, and 6 rabbits infected with 40 metacercariae), and 10 heavily-infected rabbits (500 metacercariae). The sonographic criterion of diagnosis with dilatation of the intrahepatic ducts. We sacrificed lightly-infected rabbits and counted numbers of adult worms of clonorchis sinensis 9 weeks after infection. Sonographic abnormalities were found 3 weeks after infection in 2 lightly-infected rabbits and 5 heavily-infected rabbits. On sonography at 9 weeks after infection, we observed dilatation of the intrahepatic ducts in 11 (65%) of 17 lightly-infected rabbits and all of 10 heavily-infected rabbits. High-resolution sonography is very useful in early diagnosis of rabbits clonorchiasis.

  2. Usefulness of high-resolution sonography in early diagnosis of rabbit clonorchiasis

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jae Hoon; Choi, Don Gil; Chung, Il Gyu; Phyun, Lae Hyun; Pyeun, Yong Seon [Sungkyunkwan University College of Medicine, Seoul (Korea, Republic of); Hong, Sung Tae; Lee, Me Jeong [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1999-09-15

    To determine the role of high-resolution sonography in the early diagnosis of experimentally induced clonorchiasis in rabbits. We performed sonographic examination weekly in 22 lightly-infected rabbits (10 rabbits infected with 10 metacercariae, 6 rabbits infected with 20 metacercariae, and 6 rabbits infected with 40 metacercariae), and 10 heavily-infected rabbits (500 metacercariae). The sonographic criterion of diagnosis with dilatation of the intrahepatic ducts. We sacrificed lightly-infected rabbits and counted numbers of adult worms of clonorchis sinensis 9 weeks after infection. Sonographic abnormalities were found 3 weeks after infection in 2 lightly-infected rabbits and 5 heavily-infected rabbits. On sonography at 9 weeks after infection, we observed dilatation of the intrahepatic ducts in 11 (65%) of 17 lightly-infected rabbits and all of 10 heavily-infected rabbits. High-resolution sonography is very useful in early diagnosis of rabbits clonorchiasis.

  3. High resolution compression elastography and color doppler sonography in characterization of breast fibroadenoma.

    Science.gov (United States)

    Rjosk-Dendorfer, D; Reu, S; Deak, Z; Hetterich, H; Kolben, T; Reiser, M; Clevert, D A

    2014-01-01

    To evaluate the use of color Doppler sonography and free hand sonoelastography in the assessment of breast fibroadenomas according to their size and shape. From December 2012 to March 2013 women with 16 solid breast masses, classified as BI-RADS category 3 or 4 were examined with B-mode ultrasound, sonoelastography and color Doppler sonography. Lesions were subdivided according to their shape in round, ovoid or macrolobulated and according to their size (fibroadenomas in B-mode sonography could be shown (p = 0.91) and also comparison of Tsukuba-scores and size of masses revealed no significant differences (p = 1.0). Sizes of fibroadenomas ≥2 cm were significantly associated with an increased vascularization of the lesions (p = 0.04) and a macrolobulated appearance in B-mode sonography (p = 0.04). The combination of color Doppler sonography and sonoelastography in addition to B-mode sonography leads to an increased accuracy in distinguishing benign from malignant breast masses and to an improvement in characterization of fibroadenomas independent of their shape or size.

  4. The value of high-resolution sonography and MR imaging in the diagnosis and follow-up of carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Buchberger, W.; Judmaier, W.; Birbamer, G.; Hasenoehrl, K.; Schmidauer, C.

    1993-01-01

    120 wrists of 105 patients with carpal tunnel syndrome were studied preoperatively by high-resolution sonography. Follow-up examinations after carpal tunnel release were performed in 72 wrists. In addition, 40 wrists were examined preoperatively, and 20 wrists were examined postoperatively by MR imaging. Based on quantitative analysis of the cross-sectional area and shape of the median nerve and of the palmar bowing of the flexor retinaculum, sonography established the diagnosis in 95% of cases. MR was superior in the evaluation of mild degrees of median nerve compression, and in the detection of possible causes of the carpal tunnel syndrome, such as synovitis of the flexor tendon sheaths or ganglionic cysts. In postoperative follow-up, sonographic demonstration of a normally flattened median nerve was an excellent indicator of the successful carpal tunnel release. In 10 patients with persistent or recurrent symptoms after carpal tunnel release, the underlying pathology could be exactly demonstrated by MR. (orig.) [de

  5. Diagnostic value of high-resolution B-mode and power-mode sonography in the follow-up of thyroid cancer.

    Science.gov (United States)

    Görges, Rainer; Eising, E G; Fotescu, D; Renzing-Köhler, K; Frilling, A; Schmid, K W; Bockisch, A; Dirsch, O

    2003-02-01

    Ultrasonography is an established diagnostic modality in the follow-up of thyroid cancer. Color flow Doppler has been proposed by some authors as an additional tool for differentiating benign from malignant cervical lesions in various types of head and neck cancer. Over the last few years, a new generation of high-resolution ultrasound platforms with the "power-mode" feature has become available, that also enables the imaging of small vessel blood flow. The objective of our study was to find ways of optimizing the differentiation of benign and malignant cervical tumors in thyroid cancer follow-up by means of sonography. Hundred and twelve cervical lesions in 90 patients with thyroid cancer were evaluated by high-end ultrasonography (Sonoline Elegra, Siemens) using a small-part transducer (7.5 L 40, Siemens). B-mode sonography was performed at a frequency of 8 MHz. The Solbiati index (SI= ratio of largest to smallest diameter), configuration, echogenicity, intranodular structures, and margins were assessed. Perinodular and intranodular blood flow was evaluated by color flow Doppler (PRF 1250 Hz for conventional color flow Doppler, 868 Hz for power-mode Doppler). Possible malignancy was validated by histology, cytology, scintigraphy, and follow-up. Thirty five lesions were benign (diameter 0.4-3.0 cm) and 77 were malignant (0.4-5.4 cm). The patients were randomized into a test group and a learning group to determine the diagnostic value of various ultrasound criteria by means of statistical analysis. In the learning group, decision rules based on the dichotomized criteria were developed using a logistic regression model. Sensitivity and specificity of these decision rules were then evaluated in the test group. The presence of an echocomplex pattern or irregular hyperechoic small intranodular structures (criterion A) and the presence of an irregular diffuse intranodular blood flow (criterion B) are the best indicators of malignancy, whereas an SI >2 is highly

  6. New developments in imaging: Sonography, cine-CT, MRI

    International Nuclear Information System (INIS)

    Otto, R.J.; Higgins, C.B.

    1987-01-01

    The book can be conveniently subdivided into three sections: the first on magnetic resonance imaging the second on cine-computed tomography and the third on advances in ultrasound (US). The MR imaging section includes two chapters: the first on indications for MR in abdominal disease (a cookbook layout of indications for MR imaging versus CT) and the second on MR imaging of the heart. There are also chapters on MR imaging and US in the pelvis, contrast agent principles, and a chapter on imaging renal tumors. The third section, on US, contains chapters on the liver and gastrointenstinal disease, interventional US sonography during neurosurgery, state-of-the-art echocardiography. Doppler flow imaging, contrast media for sonography, endometrial sonography, and high-resolution US in the first trimester. The final chapter is presented as a scientific paper rather than as a chapter in a book and has no illustrations

  7. Specific preoperative diagnosis of choledochal cysts by combined sonography and hepatobiliary scintigraphy

    International Nuclear Information System (INIS)

    Papanicolaou, N.; Abramson, S.J.; Teele, R.L.; Treves, S.

    1985-01-01

    The combined use of sonography and hepatobiliary scintigraphy correctly identified a choledochal cyst preoperatively in seven consecutive infants and children. The high resolution anatomic images provided by sonography coupled with physiologic data on filing of the cyst, biliary patency and liver function derived from radionuclide scanning offer valuable information in the diagnosis and planning of corrective surgery of the cyst and coexisting hepatobiliary anomalies. Invasive diagnostic procedures should be reserved for occasional problematic cases [fr

  8. High-resolution sonography in carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Solbiati, L.; De Pra, L.; Rizzatto, G.; Derchi, L.E.

    1986-01-01

    Carpal tunnel syndrome, caused by the compression on the median nerve under the transverse carpal ligament, has multiple causes and clinical presentations. One hundred eighteen patients with carpal tunnel sydrome underwent high-resolution US which demonstrated unpalpable cystic masses in 25 patients (lobulated stalked synovial cysts in 19 and retrotendinous cysts in six, all confirmed at surgery), and diffuse thickening and decreased echogenicity of the tendon sheaths in 87 patients, suggesting tenosynovitis (confirmed at surgery in 64). In six patients simple encasement of muscle bellies in the carpal tunnel was shown. US can delineate the cause of carpal tunnel syndrome, suggest the need for surgery, and aid the surgeon in locating the lesion to be removed

  9. Power Doppler sonography and ultrasound contrast agent in assessing rheumatoid synovitis

    Directory of Open Access Journals (Sweden)

    F. Salaffi

    2011-09-01

    Full Text Available Pannus formation is a fundamental event in the pathogenesis of rheumatoid arthritis and its hypervascularisation seems to be crucial to the development of joint damage. High-resolution greyscale ultrasonography is a safe, quick, and inexpensive imaging tool that allows an accurate detection of even minimal morphostructural changes in patients with rheumatoid arthritis, including joint effusion, thickening of synovial membrane and bone erosions. More recently, power Doppler sonography has proved to be a reliable tool for semiquantitative assessment of the vascularity of the synovial tissue. The contrast-enhanced power Doppler sonography seems to be a helpful adjunct in assessing synovitis and the therapeutic response to the different therapies in patients with rheumatoid arthritis. The aim of this radiological vignette was to show a representative example of use of power Doppler sonography with contrast agent in assessing rheumatoid synovitis.

  10. 10 MHz b-scan sonography of the cervical carotid arteries

    International Nuclear Information System (INIS)

    Kuhn, F.P.; Kraemer, G.; Bauer, R.; Klotter, H.J.; Mainz Univ.; Mainz Univ.

    1984-01-01

    Two hundred and eighty-two consecutive patients with cerebro-vascular insufficiency, with non-specific neurological symptoms or asymptomatic murmurs, were examined prospectively by two-dimensional high resolution 10 MHz B-scan real time sonography. Arteriosclerotic plaques were usually semi-circular (77%), of high amplitude (64%) and homogeneous (80%). Ulcerating plaques were correctly diagnosed in only three out of eight cases demonstrated angiographically. So far there has been no definite relationship between the appearance of the plaques and clinical symptoms. Compared with arteriography (170 examinations) the specificity of sonography was 98% (62/63), the sensitivity for plaques was 100% (50/50), for stenoses it was 63% (5/8) to 93% (14/15), for occlusions it was 76% (13/17). The indications and drawbacks of the method are discussed. (orig.) [de

  11. The impact of high-resolution ultrasound in the differential diagnosis of non-hemolytic jaundice.

    Science.gov (United States)

    Rauh, Peter; Neye, Holger; Mönkemüller, Klaus; Malfertheiner, Peter; Rickes, Steffen

    2010-12-01

    Because jaundice is a common reason for hospital admission. A fast and correct differential diagnosis is very important to increase treatment efficacy. The aim of our study was to evaluate the impact of the high-resolution ultrasound in this kind of clinical setting. In a prospective study we included 30 patients and we divided them in patients with extrahepatic jaundice and patients with intrahepatic jaundice. We observed a high accuracy of the high-resolution sonography, with a sensitivity of 95% and a specificity of 100% for extrahepatic jaundice, and a sensitivity of 100% and a specificity of 95% for intrahepatic jaundice. We conclude that the high-resolution ultrasound should be used in the very beginning of the diagnostic algorithm for the evaluation of patients with unclear jaundice.

  12. Not all ultrasounds are created equal: general sonography versus musculoskeletal sonography in the detection of rotator cuff tears

    Science.gov (United States)

    Cole, Brandi; Twibill, Kristen; Lam, Patrick; Hackett, Lisa

    2016-01-01

    Background This cross-sectional analytic diagnostic accuracy study was designed to compare the accuracy of ultrasound performed by general sonographers in local radiology practices with ultrasound performed by an experienced musculoskeletal sonographer for the detection of rotator cuff tears. Methods In total, 238 patients undergoing arthroscopy who had previously had an ultrasound performed by both a general sonographer and a specialist musculoskeletal sonographer made up the study cohort. Accuracy of diagnosis was compared with the findings at arthroscopy. Results When analyzed as all tears versus no tears, musculoskeletal sonography had an accuracy of 97%, a sensitivity of 97% and a specificity of 95%, whereas general sonography had an accuracy of 91%, a sensitivity of 91% and a specificity of 86%. When the partial tears were split with those ≥ 50% thickness in the tear group and those tear group, musculoskeletal sonography had an accuracy of 97%, a sensitivity of 97% and a specificity of 100% and general sonography had an accuracy of 85%, a sensitivity of 84% and a specificity of 87%. Conclusions Ultrasound in the hands of an experienced musculoskeletal sonographer is highly accurate for the diagnosis of rotator cuff tears. General sonography has improved subsequent to earlier studies but remains inferior to an ultrasound performed by a musculoskeletal sonographer. PMID:27660657

  13. Gastrointestinal tract sonography in fetuses and children

    Energy Technology Data Exchange (ETDEWEB)

    Couture, Alain; Baud, Catherine; Ferran, Jean Louis; Saguintaah, Magali; Veyrac, Corinne [Hopital Arnaud de Villeneuve, 34 - Montpellier (France). Service de Radiologie Pediatrique

    2008-07-01

    Sonography of the gastrointestinal tract in fetuses, neonates and children entails no known biological risk, permits serial scanning and can provide information unobtainable with any other imaging modality. In experienced hands it can be used as the initial imaging technique in a number of gastrointestinal diseases and conditions. This book provides a comprehensive account of the current state of the art regarding sonography in this context. An introductory chapter compares the merits of sonography and magnetic resonance imaging of the fetal gastrointestinal tract. Subsequent chapters focus on the technique, pitfalls and findings in a wide variety of applications, including antropyloric diseases, bowel obstruction, bowel wall thickening, colitis, appendicitis, some types of intussusception, abdominal wall and umbilical abnormalities, intraperitoneal tumors, and trauma. In each case the sonographic morphology is considered in depth with the aid of high-quality illustrations. A concluding chapter comprises a quiz based on 15 case reports. Gastrointestinal Tract Sonography in Fetuses and Children will be of value to all with an interest in this field. (orig.)

  14. Impact of real-time virtual sonography, a coordinated sonography and MRI system that uses an image fusion technique, on the sonographic evaluation of MRI-detected lesions of the breast in second-look sonography.

    Science.gov (United States)

    Nakano, Shogo; Kousaka, Junko; Fujii, Kimihito; Yorozuya, Kyoko; Yoshida, Miwa; Mouri, Yukako; Akizuki, Miwa; Tetsuka, Rie; Ando, Takahito; Fukutomi, Takashi; Oshima, Yukihiko; Kimura, Junko; Ishiguchi, Tsuneo; Arai, Osamu

    2012-08-01

    The aim of this study was to verify the utility of second-look sonography using real-time virtual sonography (RVS)-a coordinated sonography with an MRI system that uses an image fusion technique with magnetic navigation-on the sonographic evaluation of MRI-detected lesions of the breast. Of the 196 consecutive patients who were examined with breast MRI in our hospital from 2006 to 2009, those patients who underwent second-look sonography to identify MRI-detected lesions were enrolled in this study. MRI was performed using a 1.5-T imager with the patient in a supine position. To assess the efficacy benefits of RVS, the correlations between lesion detection rates, MRI features, distribution, and histopathological classification on second-look sonography using conventional B-mode or RVS were analyzed. Of the 196 patients, 55 (28 %) demonstrated 67 lesions initially detected by MRI, followed by second-look sonography. Of the 67 MRI-detected lesions, 18 (30 %) were identified with second-look sonography using conventional B-mode alone, whereas 60 (90 %) lesions were detected with second-look sonography using RVS (p use of RVS on second-look sonography significantly increases the sonographic detection rate of MRI-detected lesions without operator dependence.

  15. MR-Venography Using High Resolution True-FISP

    Energy Technology Data Exchange (ETDEWEB)

    Spuentrup, E. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Beth Israel Deaconess Medical Center, Boston, MA (United States). Dept. of Medicine; Harvard Medical School, Boston, MA (United States); Buecker, A.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Stuber, M. [Beth Israel Deaconess Medical Center, Boston, MA (United States). Dept. of Medicine; Harvard Medical School, Boston, MA (United States); Philips Med. Syst., Best (Netherlands)

    2001-08-01

    A new fast MR-venography approach using a high resolution True-FISP imaging sequence was investigated in 20 patients suffering from 23 deep vein thromboses. Diagnosis was proven by X-ray venography, CT or ultrasound examination. The presented technique allowed for clear thrombus visualization with a high contrast to the surrounding blood pool even in calf veins. Acquisition time was less than 10 minutes for imaging the pelvis and the legs. No contrast media was needed. The presented high resolution True-FISP MR-veography is a promising non-invasive, fast MR-venography approach for detection of deep venous thrombosis. (orig.) [German] Eine neue schnelle, oertlich hochaufgeloeste MR-Phlebographietechnik mit einer axialen True-FISP Bildgebungssequenz wurde an 20 Patienten mit 23 nach-gewiesenen tiefen Beinvenenthrombosen untersucht. Die Befunde wurden mit einer konventionellen Roentgenphlebographie, einer CT oder einer Sonographie gesichert. Die vorgestellte Technik erlaubte in allen Faellen eine Thrombusdarstellung mit hohem Kontrast zum umgebenden venoesen Blut, wobei aufgrund der hohen Ortsaufloesung auch die Unterschenkelvenen beurteilt werden konnten. Die Datenaufnahmezeit zur Untersuchung des Beckens und der Beine betrug weniger als 10 Minuten. Kontrastmittel wurde nicht benoetigt. Die vorgestellte MR-Phlebographietechnik unter Verwendung einer oertlich hochauf-geloesten True-FISP Sequenz ist eine neue, vielversprechende, nicht-invasive Technik zur Diagnostik der tiefen Bein- und Beckenvenenthrombose. (orig.)

  16. Transvaginal sonography of acute pelvic inflammatory disease

    International Nuclear Information System (INIS)

    Choi, Jin Soo; Kim, Young Hwa; Shin, Hyung Chul; Han, Gun Soo; Kim, Il Young

    1999-01-01

    To determine the value of transvaginal sonography in evaluating women with acute pelvic inflammatory disease (PID). Transvaginal sonography was performed in 25 patients with clinically suggested PID during recent 36 months. The sonographic findings of fallopian tubes and ovaries were analyzed and correlated with pathological findings of 2 fallopian tubes and 19 ovaries in 16 patients who had operations. The correct diagnosis of acute PID was made in 20/25 (80%) by transvaginal sonography. the abnormal sonographic findings of the fallopian tube include tubal thickening or dilatation with internal echo. The sensitivity, specificity, and accuracy for tubal abnormality were 88%, 96%, and 86% , respectively. Ovarian changes were seen on TVS in 14/19 (73%), which include multiple follicular enlargement in 5, tubo-ovarian complex in 9 (tubo-ovarian adhesion in 3, tubo-ovarian abscess in 6). At surgery, the ovay was not involved in all three women who showed tubo-ovarian adhesion on TVS. Among 6 women who showed tubo-ovarian abscess on TVS, tubo-ovarian abscess was confirmed in 3 and the remaining 3 had ovarian cysts. Trandvaginal sonography, a facilitative and accurate modality, is highly sensitive in detecting the abnormality of the tube and useful in differentiating the tubo-ovarian complex in patients with acute PID.

  17. Magnetic resonance tomography and ultrasound in rheumatology; MRT und Sonographie in der Rheumatologie

    Energy Technology Data Exchange (ETDEWEB)

    Kainberger, F. [Universitaetsklinik fuer Radiodiagnostik, Ludwig-Boltzmann-Inst. fuer Physikalische und Radiologische Tumordiagnostik, Wien (Austria); Czerny, C. [Universitaetsklinik fuer Radiodiagnostik, Ludwig-Boltzmann-Inst. fuer Physikalische und Radiologische Tumordiagnostik, Wien (Austria); Trattnig, S. [Universitaetsklinik fuer Radiodiagnostik, Ludwig-Boltzmann-Inst. fuer Physikalische und Radiologische Tumordiagnostik, Wien (Austria); Lack, W. [Universitaetsklinik fuer Orthopaedie, Wien (Austria); Machold, K. [Universitaetsklinik fuer Innere Medizin III, Wien (Austria). Abt. fuer Rheumatologie; Graninger, W. [Universitaetsklinik fuer Innere Medizin III, Wien (Austria). Abt. fuer Rheumatologie

    1996-08-01

    Technical innovations and software improvements in magnetic resonance imaging (MRI) and high-resolution sonography (US) have definitely influenced the diagnostic imaging of rheumatic diseases. For MRI, improvements in surface coils, dedicated low-field systems (0.2 T), and software improvements (shorter acquisition times and refinements of fat suppressing techniques) must be mentioned. For sonography, the main innovations concern the development of higher transducer frequencies (7-15 Mhz) and power Doppler imaging. Clinical evaluations have shown that MRI and US are most useful in cases of suspected rheumatic disease with negative plain film radiographs and for documenting the course of the disease, diagnosing of early rheumatoid arthritis, making a differential diagnosis in clinically unclear rheumatic diseases, investigating vascularization, and quantifying pannus formation. In order to improve diagnostic efficacy the role of MRI and US in the management of patients with rheumatic disease should be reconsidered. (orig.) [Deutsch] Technische Innovationen in Hard- und Software von Magnetresonanztomographie (MRT) und Sonographiegeraeten haben die bildgebende Diagnostik in der Rheumatologie massgeblich beeinflusst (Verbesserungen der Oberflaechenspulen mit hohen Gradientenfeldern, dedizierte Niederfeldgeraete, Softwareverbesserungen in Form von kuerzeren Aquisitionszeiten und Verfeinerungen in der Fettunterdrueckung, hoehere Transducerfrequenzen zwischen 7 und 15 Mhz, Powerdopplerverfahren). Fuer die klinische Anwendung bedeutet dies, dass MRT und Sonographie als bildgebende Zusatzverfahren nach der Anfertigung konventioneller Roentgenaufnahmen anzuwenden sind, wenn diese unauffaellige Resultate ergeben oder spezielle Fragen zur Schwere des Krankheitsprozesses bzw. von Folgeerscheinungen zu beantworten sind. Im besonderen betrifft dies den Nachweis der Frueharthritis, die Differentialdiagnose klinisch nicht klar einzuordnender Krankheitsbilder und die Bestimmung des

  18. Focused abdominal sonography for trauma (FAST) in blunt paediatric abdominal trauma

    International Nuclear Information System (INIS)

    Faruque, A. V.; Qazi, S. H.; Khan, M. A. M.

    2013-01-01

    Objective: To evaluate the role of focussed abdominal sonography for trauma in blunt paediatric abdominal trauma patients, and to see if the role of computed tomography scan could be limited to only those cases in which sonography was positive. Methods: The retrospective study covered 10 years, from January 1, 2000 to December 31, 2009, and was conducted at the Department of Radiology and Department of Emergency Medicine, Aga Khan University Hospital, Karachi. It comprised cases of 174 children from birth to 14 years who had presented with blunt abdominal trauma and had focussed abdominal sonography for trauma done at the hospital. The findings were correlated with computed tomography scan of the abdomen and clinical follow-up. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of focussed abdominal sonography for trauma were calculated for blunt abdominal trauma. SPSS 17 was used for statistical analysis. Results: Of the total 174 cases, 31 (17.81%) were later confirmed by abdominal scan. Of these 31 children, sonography had been positive in 29 (93.54%) children. In 21 (67.74%) of the 31 children, sonography had been true positive; 8 (25%) (8/31) were false positive; and 2 (6%) (2/31) were false negative. There were 6 (19.3%) children in which sonography was positive and converted to laparotomy. There was no significant difference on account of gender (p>0.356). Focussed abdominal sonography for trauma in the study had sensitivity of 91%, specificity of 95%, positive predictive value of 73%, and negative predictive value of 73% with accuracy of 94%. All patients who had negative sonography were discharged later, and had no complication on clinical follow-up. Conclusions: Focussed abdominal sonography for trauma is a fairly reliable mode to assess blunt abdominal trauma in children. It is a useful tool to pick high-grade solid and hollow viscous injury. The results suggest that the role of computed tomography scan can be

  19. Perforated pyloroduodenal peptic ulcer and sonography.

    Science.gov (United States)

    Kuzmich, Siarhei; Harvey, Chris J; Fascia, Daniel T M; Kuzmich, Tatsiana; Neriman, Deena; Basit, Rizwan; Tan, Kai Lee

    2012-11-01

    The purpose of this article is to illustrate the spectrum of sonographic findings in perforated pyloroduodenal peptic ulcer and discuss the potential role of sonography in the diagnosis. Although sonography is not the first-line investigation of choice in suspected perforated peptic ulcer, understanding of the characteristic appearances seen during general abdominal sonography may aid the reader in the diagnosis of this important and sometimes overlooked cause of nonspecific abdominal pain. This may shorten time to the diagnosis and ultimate surgical management.

  20. Diagnostic accuracy of sonography for pleural effusion: systematic review

    Directory of Open Access Journals (Sweden)

    Alexandre Grimberg

    Full Text Available CONTEXT AND OBJECTIVE: The initial method for evaluating the presence of pleural effusion was chest radiography. Isolated studies have shown that sonography has greater accuracy than radiography for this diagnosis; however, no systematic reviews on this matter are available in the literature. Thus, the aim of this study was to evaluate the accuracy of sonography in detecting pleural effusion, by means of a systematic review of the literature. DESIGN AND SETTING: This was a systematic review with meta-analysis on accuracy studies. This study was conducted in the Department of Diagnostic Imaging and in the Brazilian Cochrane Center, Discipline of Emergency Medicine and Evidence-Based Medicine, Department of Medicine, Universidade Federal de São Paulo (Unifesp, São Paulo, Brazil. METHOD: The following databases were searched: Cochrane Library, Medline, Web of Science, Embase and Literatura Latino-Americana e do Caribe em Ciências da Saúde (Lilacs. The references of relevant studies were also screened for additional citations of interest. Studies in which the accuracy of sonography for detecting pleural effusion was tested, with an acceptable reference standard (computed tomography or thoracic drainage, were included. RESULTS: Four studies were included. All of them showed that sonography had high sensitivity, specificity and accuracy for detecting pleural effusions. The mean sensitivity was 93% (95% confidence interval, CI: 89% to 96%, and specificity was 96% (95% CI: 95% to 98%. CONCLUSIONS: In different populations and clinical settings, sonography showed consistently high sensitivity, specificity and accuracy for detecting fluid in the pleural space.

  1. Brain sonography in African infants with complicated sporadic ...

    African Journals Online (AJOL)

    Background: To determine the structural findings in brain sonography of African infants with complicated sporadic bacterial meningitis. Materials and Methods: Retrospective assessment of medical records of patients who underwent brain sonography on account of complicated bacterial meningitis. The brain sonography ...

  2. Three-dimensional power Doppler sonography in screening for carotid artery disease.

    Science.gov (United States)

    Keberle, M; Jenett, M; Beissert, M; Jahns, R; Haerten, R; Hahn, D

    2000-01-01

    Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment. Copyright 2000 John Wiley & Sons, Inc.

  3. Focused abdominal sonography for trauma (FAST) in blunt paediatric abdominal trauma.

    Science.gov (United States)

    Faruque, Ahmad Vaqas; Qazi, Saqib Hamid; Khan, Muhammad Arif Mateen; Akhtar, Wassem; Majeed, Amina

    2013-03-01

    To evaluate the role of focussed abdominal sonography for trauma in blunt paediatric abdominal trauma patients, and to see if the role of computed tomography scan could be limited to only those cases in which sonography was positive. The retrospective study covered 10 years, from January 1,2000 to December 31,2009, and was conducted at the Department of Radiology and Department of Emergency Medicine, Aga Khan University Hospital, Karachi. It comprised cases of 174 children from birth to 14 years who had presented with blunt abdominal trauma and had focussed abdominal sonography for trauma done at the hospital. The findings were correlated with computed tomography scan of the abdomen and clinical follow-up. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of focussed abdominal sonography for trauma were calculated for blunt abdominal trauma. SPSS 17 was used for statistical analysis. Of the total 174 cases, 31 (17.81%) were later confirmed by abdominal scan. Of these 31 children, sonography had been positive in 29 (93.54%) children. In 21 (67.74%) of the 31 children, sonograpy had been true positive; 8 (25%) (8/31) were false positive; and 2 (6%) (2/31) were false negative. There were 6 (19.3%) children in which sonography was positive and converted to laparotomy. There was no significant difference on account of gender (p>0.356). Focussed abdominal sonography for trauma in the study had sensitivity of 91%, specificity of 95%, positive predictive value of 73%, and negative predictive value of 73% with accuracy of 94%. All patients who had negative sonography were discharged later, and had no complication on clinical follow-up. Focussed abdominal sonography for trauma is a fairly reliable mode to assess blunt abdominal trauma in children. It is a useful tool to pick high-grade solid and hollow viscous injury. The results suggest that the role of computed tomography scan can be limited to those cases in which focussed

  4. Mammography and breast sonography in transsexual women

    International Nuclear Information System (INIS)

    Weyers, S.; Villeirs, G.; Vanherreweghe, E.; Verstraelen, H.; Monstrey, S.; Van den Broecke, R.; Gerris, J.

    2010-01-01

    Data on the necessity of performing screening mammographies in transsexual women are lacking. The main objective of this study was to assess the possibility to perform mammography and breast sonography in transsexual women. Fifty Dutch-speaking transsexual women were interviewed about the following: attitude towards mammography and breast sonography, importance attributed to and satisfaction with breast appearance, opinion about the necessity of breast check-up, expectations regarding discomfort during the exams and knowledge about the breast surgery. A fasting blood sample, clinical breast exam, mammography and breast sonography were performed. At mammography the following parameters were noted: density, technical quality, location of the prostheses, presence of any abnormalities and painfulness. At sonography the following parameters were recorded: density, presence of cysts, visualisation of retro-areolar ducts or any abnormalities. Twenty-three percent of patients are not aware of the type of breast implants and 79% do not know their position to the pectoral muscles. Patient satisfaction with the appearance of their breasts was rather high (7.94 on a scale of 0-10). Mean expected and experienced pain from mammography was low (4.37 and 2.00 respectively). There was no statistically significant difference in expected pain between those who already had mammography and those who did not. There was a significant positive correlation between the expected and the experienced pain. Mammography and breast sonography were technically feasible and no gross anomalies were detected. Since both exams were judged as nearly painless, 98% of transsexual women intended to come back if they would be invited. Since breast cancer risk in transsexual women is largely unknown and breast exams are very well accepted, breast screening habits in this population should not differ from those of biological women.

  5. Mammography and breast sonography in transsexual women

    Energy Technology Data Exchange (ETDEWEB)

    Weyers, S., E-mail: steven.weyers@ugent.b [Department of Gynecology, Ghent University Hospital, De Pintelaan 185, B-9000 Ghent (Belgium); Villeirs, G.; Vanherreweghe, E. [Department of Radiology, Ghent University Hospital, Ghent (Belgium); Verstraelen, H. [Department of Gynecology, Ghent University Hospital, De Pintelaan 185, B-9000 Ghent (Belgium); Monstrey, S. [Department of Plastic Surgery, Ghent University Hospital, Ghent (Belgium); Van den Broecke, R.; Gerris, J. [Department of Gynecology, Ghent University Hospital, De Pintelaan 185, B-9000 Ghent (Belgium)

    2010-06-15

    Data on the necessity of performing screening mammographies in transsexual women are lacking. The main objective of this study was to assess the possibility to perform mammography and breast sonography in transsexual women. Fifty Dutch-speaking transsexual women were interviewed about the following: attitude towards mammography and breast sonography, importance attributed to and satisfaction with breast appearance, opinion about the necessity of breast check-up, expectations regarding discomfort during the exams and knowledge about the breast surgery. A fasting blood sample, clinical breast exam, mammography and breast sonography were performed. At mammography the following parameters were noted: density, technical quality, location of the prostheses, presence of any abnormalities and painfulness. At sonography the following parameters were recorded: density, presence of cysts, visualisation of retro-areolar ducts or any abnormalities. Twenty-three percent of patients are not aware of the type of breast implants and 79% do not know their position to the pectoral muscles. Patient satisfaction with the appearance of their breasts was rather high (7.94 on a scale of 0-10). Mean expected and experienced pain from mammography was low (4.37 and 2.00 respectively). There was no statistically significant difference in expected pain between those who already had mammography and those who did not. There was a significant positive correlation between the expected and the experienced pain. Mammography and breast sonography were technically feasible and no gross anomalies were detected. Since both exams were judged as nearly painless, 98% of transsexual women intended to come back if they would be invited. Since breast cancer risk in transsexual women is largely unknown and breast exams are very well accepted, breast screening habits in this population should not differ from those of biological women.

  6. Sonography and electrodiagnosis in carpal tunnel syndrome diagnosis, an analysis of the literature

    International Nuclear Information System (INIS)

    Seror, P.

    2008-01-01

    We present a review of the international literature concerning sonography for the diagnosis of carpal tunnel syndrome (CTS). Analysis of the results and comparison with electrodiagnostic data provide a sensible albeit personal view on the relevance of sonography and whether it competes or is complementary to electrodiagnosis (EDX). Although EDX is considered as the gold standard for CTS diagnosis, one author chose surgical results to define CTS. The normal and threshold mean values for sonography are particularly variable from one study to another. The standard deviation (S.D.), when compared to mean values, makes normal and abnormal data overlap considerably and produces many false negatives when the specificity is high, and many false positives when the sensitivity is high. In fact, sonography is non-interpretable in only 10 to 15% of the population, and it affirms the median nerve lesion at the wrist in 55% of cases when EDX does it in more than 90% with common tests. Further more the specificity of sonography leads to a false positive diagnosis in 1 case out of 5 versus 1 out of 40 with EDX. The main conclusion is that there is no competition but rather a complementarity between sonography and EDX: sonography is certainly an efficient imaging technique but cannot replace proper EDX performed for upper limb paresthesiae. Namely, sonography can answer only one out of the 8 questions a complete EDX answer: Are sonographic images compatible with a median nerve lesion at the wrist? The answer to this solely question can be obtain with a partial EDX using a single conduction test (motor or sensitive), then duration and cost will be comparable to sonography but will be both more sensitive and specific. Finally, one must kept in mind that the final aim of all examinations in CTS is to determine the cause(s) of upper limb paresthesiae, not simply if there is a median nerve lesion at wrist or not

  7. Differential diagnosis of persistent neonatal jaundice: Role of sonography and scintigraphy

    International Nuclear Information System (INIS)

    Lee, Sun Wha; Ko, Young Tae; Lim, Jae Hoon

    1993-01-01

    The most common causes of conjugated hyperbilirubinaemia after the first or second week of life are neonatal hepatitis and biliary atresia. Since these entities represent variable expressions of same pathologic process and have similar clinical, biochemical, and histologic features, differential diagnosis is extremely difficult. We prospectively studies 28 jaundiced infants by sonography and hepatobiliary scintigraphy. Final diagnoses included 12 biliary atresia and 16 neonatal hepatitis. Visualization of a normal sized common bile duct or gallbladder was compatible with the diagnosis of neonatal hepatitis. Non-visualized or atrophic gallbladder on sonography coupled with non-visualization of bowel activity on scintigraphy was highly suggestive of biliary atresia. We believe that sonography plays a valuable role in the initial evaluation of the infants with persistent neonatal jaundice. The combined use of sonography and hepatobiliary scintigraphy provides the most valuable information in suspected biliary atresia for prompt surgical treatment

  8. Sonography for diagnosis of benign and malignant tumors of the nose and paranasal sinuses.

    Science.gov (United States)

    Liu, Jun-jie; Gao, Yong; Wu, Ya-Fei; Zhu, Shang-Yong

    2014-09-01

    The purpose of this study was to demonstrate the reliability of sonography for diagnosis of nose and paranasal sinus tumors. Ninety-six consecutive patients with tumors underwent sonography and computed tomography (CT) before surgical treatment. Tumor detectability and imaging findings were evaluated independently and then compared with pathologic findings. Of 96 tumors, 75 were detected by sonography, for a detectability rate of 78.1%; 93 tumors were detected by CT, for a detectability rate of 96.9%. By comparison, sonography showed a trend toward higher detectability of nasal vestibular tumors than CT (87.5% for sonography versus 50.0% for CT) and small lumps on the wing of the nose (78.8% for sonography versus 33.3% for CT). Among the sonographic features, boundary, shape, internal echo, calcification, bone invasion, vascular pattern, and cervical lymph node metastasis all had significantly positive correlations with malignancy (P benign and malignant tumors of the nose and paranasal sinuses. Consequently, sonography has high value for diagnosis of benign and malignant tumors of the nose and paranasal sinuses, especially for nasal vestibular tumors and small lumps on the wing of the nose. © 2014 by the American Institute of Ultrasound in Medicine.

  9. Clinical application of a modern high-definition head-mounted display in sonography.

    Science.gov (United States)

    Takeshita, Hideki; Kihara, Kazunori; Yoshida, Soichiro; Higuchi, Saori; Ito, Masaya; Nakanishi, Yasukazu; Kijima, Toshiki; Ishioka, Junichiro; Matsuoka, Yoh; Numao, Noboru; Saito, Kazutaka; Fujii, Yasuhisa

    2014-08-01

    Because of the remarkably improved image quality and wearability of modern head-mounted displays, a monitoring system using a head-mounted display rather than a fixed-site monitor for sonographic scanning has the potential to improve the diagnostic performance and lessen the examiner's physical burden during a sonographic examination. In a preclinical setting, 2 head-mounted displays, the HMZ-T2 (Sony Corporation, Tokyo, Japan) and the Wrap1200 (Vuzix Corporation, Rochester, NY), were found to be applicable to sonography. In a clinical setting, the feasibility of the HMZ-T2 was shown by its good image quality and acceptable wearability. This modern device is appropriate for clinical use in sonography. © 2014 by the American Institute of Ultrasound in Medicine.

  10. 21 CFR 872.2050 - Dental sonography device.

    Science.gov (United States)

    2010-04-01

    ... § 872.9. (b) Dental sonography device for interpretation and diagnosis—(1) Identification. A dental sonography device for interpretation and diagnosis is an electrically powered device, intended to interpret temporomandibular joint sounds for the diagnosis of temporomandibular joint disorders and associated orofacial pain...

  11. Sonography as an initial study in patients with suspected ureteral stone

    International Nuclear Information System (INIS)

    Lee, Jae Gue; Lim, Joo Won; Ko, Young Tae; Lee, Dong Ho; Lee, Hye Won; Oh, Joo Hyeong; Yoon, Yup; Lee, Sun Ju

    1999-01-01

    To evaluate the usefulness of sonography as an initial study in patients with suspected ureteral stone. We have undertaken a prospective study for 106 patients with suspected ureteral stone during 15 months. All the patients subsequently underwent urography at a mean interval of 1.8 days after the abdominopelvic sonography. We had only a clinical impression at the sonography and didn't refer to the other study such as KUB. We observed the degree of hydronephrosis using a grading system by Ellenbogen et aland location and size of stone. Seventy four patients had ureteral stone disease. The sonographic findings of these 74 patients showed a stone with hydronephrosis in 61 patients, a stone without hydronephrosis in 9, only hydronephrosis without stone in 2, and unremarkable finding in 2. In 3 of the remaining 32 patients, sonography showed hydronephrosis without stone. Locations of stone were 9 patients of ureteropelvic junction(UPJ), 19 of proximal ureter, 30 of distal ureter, and 16 of ureterovesical junction(UVJ). The sensitivity of sonography for stone was 95% and the specificity was 100%. When a ureteral stone was present, ipsilateral hydronephrosis was detected in 85% of cases on sonography. When only hydronephrosis without stone was detected on sonography, a ureteral stone was diagnosed in 2(40%) of 5 patients. Mean discrepancy of stone size between sonography and KUB was 3.1mm and stone size on sonography was larger. Grade of hydronephrosis between sonography and urography was the same in 32(59%) of 54 patients, whose stones were not expelled until urography after sonography. Sonography could be used as an initial study in patients with suspected ureteral stone.

  12. The accuracy of chest sonography in the diagnosis of small pleural effusion

    International Nuclear Information System (INIS)

    Kocijancic, I.

    2003-01-01

    Background. The aim of the study was to evaluate the accuracy of chest sonography in the radiological diagnosis of small pleural effusions. Patients and methods. Patients referred for abdominal and/or chest sonographies for various reasons were examined for sonographic features of pleural effusion. From January 1997 till January 2000, 69 patients were included into the study. Fifty-two patients were found to have pleural effusion not exceeding 15 mm in depth, the rest of them served as controls. Subsequently erect posteroanterior and expiratory lateral decubitus projections were done in all patients. Results. Compared to radiological examination chest sonography had a positive predictive value of 92% in the diagnosis of small pleural effusions in our study population. The mean thickness of fluid was 9.2 mm on ultrasonography and 7.6 mm on expiratory lateral decubitus views (P<0.01). Conclusions. Chest sonography showed a high degree of accuracy for demonstrating small pleural effusions and could replace lateral decubitus chest radiographs adequately. (author)

  13. Intelligent navigation to improve obstetrical sonography.

    Science.gov (United States)

    Yeo, Lami; Romero, Roberto

    2016-04-01

    'Manual navigation' by the operator is the standard method used to obtain information from two-dimensional and volumetric sonography. Two-dimensional sonography is highly operator dependent and requires extensive training and expertise to assess fetal anatomy properly. Most of the sonographic examination time is devoted to acquisition of images, while 'retrieval' and display of diagnostic planes occurs rapidly (essentially instantaneously). In contrast, volumetric sonography has a rapid acquisition phase, but the retrieval and display of relevant diagnostic planes is often time-consuming, tedious and challenging. We propose the term 'intelligent navigation' to refer to a new method of interrogation of a volume dataset whereby identification and selection of key anatomical landmarks allow the system to: 1) generate a geometrical reconstruction of the organ of interest; and 2) automatically navigate, find, extract and display specific diagnostic planes. This is accomplished using operator-independent algorithms that are both predictable and adaptive. Virtual Intelligent Sonographer Assistance (VIS-Assistance®) is a tool that allows operator-independent sonographic navigation and exploration of the surrounding structures in previously identified diagnostic planes. The advantage of intelligent (over manual) navigation in volumetric sonography is the short time required for both acquisition and retrieval and display of diagnostic planes. Intelligent navigation technology automatically realigns the volume, and reorients and standardizes the anatomical position, so that the fetus and the diagnostic planes are consistently displayed in the same manner each time, regardless of the fetal position or the initial orientation. Automatic labeling of anatomical structures, subject orientation and each of the diagnostic planes is also possible. Intelligent navigation technology can operate on conventional computers, and is not dependent on specific ultrasound platforms or on the

  14. Transcranial Duplex Sonography Predicts Outcome following an Intracerebral Hemorrhage.

    Science.gov (United States)

    Camps-Renom, P; Méndez, J; Granell, E; Casoni, F; Prats-Sánchez, L; Martínez-Domeño, A; Guisado-Alonso, D; Martí-Fàbregas, J; Delgado-Mederos, R

    2017-08-01

    Several radiologic features such as hematoma volume are related to poor outcome following an intracerebral hemorrhage and can be measured with transcranial duplex sonography. We sought to determine the prognostic value of transcranial duplex sonography in patients with intracerebral hemorrhage. We conducted a prospective study of patients diagnosed with spontaneous intracerebral hemorrhage. Transcranial duplex sonography examinations were performed within 2 hours of baseline CT, and we recorded the following variables: hematoma volume, midline shift, third ventricle and lateral ventricle diameters, and the pulsatility index in both MCAs. We correlated these data with the CT scans and assessed the prognostic value of the transcranial duplex sonography measurements. We assessed early neurologic deterioration during hospitalization and mortality at 1-month follow-up. We included 35 patients with a mean age of 72.2 ± 12.8 years. Median baseline hematoma volume was 9.85 mL (interquartile range, 2.74-68.29 mL). We found good agreement and excellent correlation between transcranial duplex sonography and CT when measuring hematoma volume ( r = 0.791; P duplex sonography measurements showed that hematoma volume was an independent predictor of early neurologic deterioration (OR, 1.078; 95% CI, 1.023-1.135) and mortality (OR, 1.089; 95% CI, 1.020-1.160). A second regression analysis with CT variables also demonstrated that hematoma volume was associated with early neurologic deterioration and mortality. When we compared the rating operation curves of both models, their predictive power was similar. Transcranial duplex sonography showed an excellent correlation with CT in assessing hematoma volume and midline shift in patients with intracerebral hemorrhage. Hematoma volume measured with transcranial duplex sonography was an independent predictor of poor outcome. © 2017 by American Journal of Neuroradiology.

  15. Transvaginal versus transabdominal sonography in the evaluation of pelvic pathology

    International Nuclear Information System (INIS)

    Qureshi, I.H.; Ullah, H.; Akram, M.H.; Ashfaq, S.; Nayyar, S.

    2004-01-01

    Objective: To find the accuracy of sonographic information provided by transvaginal sonography (TVS) in pelvic pathology as compared to transabdominal sonography (TAS). Materials and Methods: Hundred patients were included in the study from a total of 212 referred for pelvic sonography. Two radiologists independently performed transabdominal and transvaginal sonography of these patients. An independent observer compared the findings. TVS was graded as superior, equal or inferior to TAS depending on the score assigned by them. Results: TVS was considered superior in 63%, equal in 27% and inferior in 10% of the cases as compared to transabdominal sonography. It was graded inferior to TAS in cases with large pelvic masses and superior in majority of cases of ovarian follicle monitoring, polycystic ovaries, endometrial carcinoma and suspected ectopic pregnancy. Cases in which both techniques were considered equal included patients with no abnormal finding, some pelvic masses and advanced pelvic inflammatory disease. Conclusion: Transvagival sonography is superior to transabdominal sonography in most cases of pelvic pathology. However, TAS should still be the initial sonographic technique for routine evaluation of the female pelvis followed by TVS if indicated. In cases of ovarian follicle monitoring, suspected polycystic ovaries, endometrial pathology and suspected ectopic pregnancy, TVS may be used as the initial sonographic technique and can even replace TAS. (author)

  16. ROLE OF HIGH RESOLUTION ULTRASONOGRAPHY IN THE EVALUATION OF POSTERIOR SEGMENT LESIONS OF THE EYE

    Directory of Open Access Journals (Sweden)

    Rashmi Nagaraju

    2015-01-01

    Full Text Available BACKGRO UND: The superficial location of the eye, its cystic composition, and the advent of high - frequency ultrasound make sonography ideal for imaging the eye. Ultrasonography is a simple, readily available, non - invasive, non - ionizing, highly accurate, real time and cost effective modality . OBJECTIVES: 1 To evaluate the accuracy of high resolution B - mode ultrasonography in the diagnosis of posterior segment lesions of eye as compared to ophthalmoscopic examination particularly in cases of opaque conducting media . 2 To evaluate sonographic appearances of various posterior segment lesions of the eye . MATERIALS AND METHODS: 1 A prospective study was carried out on 62 cases with suspected posterior segment lesions of eye. All patients clinically suspected to have p osterior segment lesions in the presence of opaque conducting media were included in the study. Cases suspected to have isolated anterior segmental and extra ocular lesions were excluded. 2 HRUS was performed with Philips IU22 using high frequency probe ( 5 to 17 MHz utilizing contact method. 3 Sonological diagnosis was made based on sonographic features such as location, morphology, echo pattern, color Doppler characteristics, kinetics of the lesion with eye movements and acoustic characteristics of the lesion. 4 Subsequent clinical, lab investigations, surgical and histopathological examinations were carried out as applicable and final diagnosis was made which was correlated with the sonological diagnosis. Sonological diagnosis was also compared with op hthalmoscopic diagnosis. STATISTICAL ANALYSES: The validities and diagnostic accuracies of high resolution ultrasound and ophthalmoscopic examinations were calculated and compared. RESULTS AND CONCLUSIONS: 1 Ultrasound was the initial imaging modality opt ed in most of the cases as it was readily available, simple and cost effective modality. It establishes the diagnosis in significant number of cases superseding the accuracy

  17. High-resolution real-time sonography and MR imaging in assessment of osteocartilaginous exostoses

    International Nuclear Information System (INIS)

    Prayer, L.M.; Kropej, D.H.; Wimberger, D.M.; Wurnig, C.F.; Kramer, J.; Kainberger, F.M.; Braun, O.H.; Ritschl, P.W.; Imhof, H.

    1991-01-01

    High-resolution real-time ultrasonography (US) and MR imaging, using both spin-echo (SE) and gradient-echo (GE) sequences, were performed prospectively in 14 patients with solitary osteocartilaginous exostoses to assess cartilage cap thickness and bursa formation. Results were compared to surgical and histopathologic findings in all cases. Both US and MR imaging were useful in evaluating exostotic cartilage cap thickness, which is supposed to be the most reliable sign of malignant transformation. Hyaline cartilage matrix had distinctive features in US and MR imaging caused by its specific histologic composition. The formation of bursae over the protruding exostoses, which results in pain and clinically could raise the suspicion of growth and malignant transformation, was demonstrated best using GE sequences. MR imaging was thus superior to US in the detection of bursa formation. (orig.)

  18. High-resolution real-time sonography and MR imaging in assessment of osteocartilaginous exostoses

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, L.M.; Kropej, D.H.; Wimberger, D.M.; Wurnig, C.F.; Kramer, J.; Kainberger, F.M.; Braun, O.H.; Ritschl, P.W.; Imhof, H. (Vienna Univ. (Austria). Depts. of Radiology, Orthopedic Surgery, Pathology, and the MR Inst.)

    1991-09-01

    High-resolution real-time ultrasonography (US) and MR imaging, using both spin-echo (SE) and gradient-echo (GE) sequences, were performed prospectively in 14 patients with solitary osteocartilaginous exostoses to assess cartilage cap thickness and bursa formation. Results were compared to surgical and histopathologic findings in all cases. Both US and MR imaging were useful in evaluating exostotic cartilage cap thickness, which is supposed to be the most reliable sign of malignant transformation. Hyaline cartilage matrix had distinctive features in US and MR imaging caused by its specific histologic composition. The formation of bursae over the protruding exostoses, which results in pain and clinically could raise the suspicion of growth and malignant transformation, was demonstrated best using GE sequences. MR imaging was thus superior to US in the detection of bursa formation. (orig.).

  19. Duplex sonography of the near-surface leg veins

    International Nuclear Information System (INIS)

    Mendoza, E.

    2007-01-01

    The book contains the following contributions: The ultrasonograph, selection of the ultrasonic transducer, anatomy of the near-surface vein system, physiology of the near-surface vein system, varicose status classification, systematics of the duplex sonography of near-surface leg veins, provocational maneuver for the duplex sonographic varicose diagnostics, exploration of vena saphena parva, perforans veins, side branches, phlebitis, sonography for varicose therapy, postsurgical sonography, deep leg veins, examination of near-surface leg veins for the pathology of the deep vein system, differential diagnostic clarification of leg oedema from the phlebologic-lymphological view, diagnostic side features along the near-surface leg veins

  20. Clinical experience with contrast infusion sonography as an Essure confirmation test.

    Science.gov (United States)

    Connor, Viviane F

    2011-06-01

    The purpose of this study was to assess the clinical experience, including the feasibility, safety, compliance, and efficacy, of contrast infusion sonography as an Essure (Conceptus Inc, Mountain View, CA) confirmation test. A retrospective chart review and telephone survey were conducted at an academic multispecialty group. The study participants were women with Essure intervention who underwent contrast infusion sonography, transvaginal sonography, and hysterosalpingography as Essure confirmation tests. The main outcome measures included the feasibility, safety, compliance, and efficacy of contrast infusion sonography as a first-line Essure confirmation test. A total of 118 women had successful bilateral Essure placement. Of the 63 who consented to contrast infusion sonography, 53 (84.1%) had proper bilateral placement and tubal occlusion and were encouraged to rely on Essure. Four were suspected of having unilateral tubal patency; hysterosalpingography in 2 confirmed bilateral tubal occlusion, and 2 were noncompliant with second-line hysterosalpingography. Three patients suspected of having unsatisfactory or uncertain placement on initial transvaginal sonography were encouraged to undergo hysterosalpingography in lieu of contrast infusion sonography, which confirmed unsatisfactory placement in 2 and proper placement and occlusion in 1. Three contrast infusion sonographic procedures could not be completed because of technical issues; therefore, contrast infusion sonography was feasible in 95.2% of the patients (60 of 63). No notable adverse events occurred. Only 17 patients were noncompliant with any confirmation test, yielding an overall compliance rate of 86% (101 of 118). No pregnancies occurred during 669 woman-months of follow-up. The average reimbursement for contrast infusion sonography was US$251.78. Preliminary clinical data suggest that contrast infusion sonography is a feasible, safe, and accurate Essure confirmation test, which is well accepted by

  1. Sonography in the diagnosis of acute appendicitis

    Directory of Open Access Journals (Sweden)

    Ahmad Ryazi

    2003-09-01

    Full Text Available Graded compressive sonography may be useful as an adjuvant in the diagnosis of acute appendicitis. To determine the role of sonography in the differential diagnosis of acute appendicitis, preappendectomy sonographic data of 164 consecutive cases in Fatemeh-Zahra Teaching Hospital were evaluated. Of 113 (68.9% patients who had acute appendicitis in histopathology, 64 (56.6% cases had preoperative sonographic diagnosis of acute appendicitis. Of 51 patients who had normal appendices, 40 (78.4% cases had normal appendices in sonographic evaluations. Sensitivity, specificity and accuracy of sonography for acute appendicitis were 56.7%, 78.4% and 0.63, respectively. The positive and negative predictive values were 85.3% and 44.49% respectively. As a result, sonographic evaluation is an additional diagnostic tool in acute appendicitis.

  2. Radiofrequency Ablation Assisted by Real-Time Virtual Sonography and CT for Hepatocellular Carcinoma Undetectable by Conventional Sonography

    International Nuclear Information System (INIS)

    Nakai, Motoki; Sato, Morio; Sahara, Shinya; Takasaka, Isao; Kawai, Nobuyuki; Minamiguchi, Hiroki; Tanihata, Hirohiko; Kimura, Masashi; Takeuchi, Nozomu

    2009-01-01

    Real-time virtual sonography (RVS) is a diagnostic imaging support system, which provides the same cross-sectional multiplanar reconstruction images as ultrasound images on the same monitor screen in real time. The purpose of this study was to evaluate radiofrequency ablation (RFA) assisted by RVS and CT for hepatocellular carcinoma (HCC) undetectable with conventional sonography. Subjects were 20 patients with 20 HCC nodules not detected by conventional sonography but detectable by CT or MRI. All patients had hepatitis C-induced liver cirrhosis; there were 13 males and 7 females aged 55-81 years (mean, 69.3 years). RFA was performed in the CT room, and the tumor was punctured with the assistance of RVS. CT was performed immediately after puncture, and ablation was performed after confirming that the needle had been inserted into the tumor precisely. The mean number of punctures and success rates of the first puncture were evaluated. Treatment effects were evaluated with dynamic CT every 3 months after RFA. RFA was technically feasible and local tumor control was achieved in all patients. The mean number of punctures was 1.1, and the success rate of the first puncture was 90.0%. This method enabled safe ablation without complications. The mean follow-up period was 13.5 month (range, 9-18 months). No local recurrence was observed at the follow-up points. In conclusion, RFA assisted by RVS and CT is a safe and efficacious method of treatment for HCC undetectable by conventional sonography.

  3. Rotator cuff ruptures of the shoulder joint, sonography - arthrography

    International Nuclear Information System (INIS)

    Triebel, H.J.; Wening, V.; Witte, G.; Hamburg Univ.

    1986-01-01

    47 patients suspected of rutpure of the rotator cuff were sonographed and arthrographed. Rupture of the rotator cuff was diagnosed in 12 cases, both diagnostic methods yielding the same result. In 29 patients sonography and arthrography did not reveal any abnormal findings. Six ruptures evident in sonography were not confirmed by arthrography and were considered false positive. Direct pointers towards rupture of the cuff would be: echoless defects, cuff cannot be visualised fully or in part and irregularities of movement during dynamic examination. Echoless 'cystic' areas in the periarticular soft parts must be considered an indirect pointer. Echorich focal findings in the echopoor cuff represent a differential diagnostic problem and we cannot give a final assessment as yet. Shoulder sonography is justified as a screening method in suspicion of rotator cuff rupture before initiating arthrography. If sonography reveals no abnormal findings, shoulder arthrography need not be performed. (orig.) [de

  4. The accuracy of transvaginal sonography to detect endometriosis cyst

    Science.gov (United States)

    Diantika, M.; Gunardi, E. R.

    2017-08-01

    Endometriosis is common in women of reproductive age. Late diagnosis is still the main concern. Currently, noninvasive diagnostic testing, such as transvaginal sonography, is recommended. The aim of the current study was to evaluate the accuracy of transvaginal sonography in diagnosing endometrial cysts in patients in Cipto Mangunkusumo Hospital, Jakarta, Indonesia. This diagnostic study was carried out at Cipto Mangunkusumo Hospital between January 2014 and June 2015. Outpatients suspected have an endometrial cyst based on the patient history and a clinical examination was recruited. The patients were then evaluated using transvaginal sonography by an experienced sonologist, according to the research protocol. The gold standard test was a histological finding in the removed surgical mass. Ninety-eight patients were analyzed. An endometrial cyst was confirmed by histology in 85 patients (87%). The accuracy, sensitivity, specificity, positive predictive value and negative predictive value of transvaginal sonography was established to be 85% (a range of 71-99%), 93%, 77%, 96%, and 63%, respectively. A significantly higher area under the curve was identified using transvaginal sonogpraphy compared to that achieved with a clinical examination alone (85% versus 79%). Transvaginal sonography was useful in diagnosing endometrial cysts in outpatients and is recommended in daily clinical practice.

  5. Acute testicular torsion in children: the role of sonography in the diagnostic workup.

    Science.gov (United States)

    Gunther, P; Schenk, J P; Wunsch, R; Holland-Cunz, S; Kessler, U; Troger, J; Waag, K L

    2006-11-01

    Acute testicular torsion in children is an emergency and has to be diagnosed urgently. Doppler sonography is increasingly used in imaging the acute scrotum. Nevertheless, in uncertain cases, surgical exploration is required. In this study, we attempted to define the role of Doppler sonography in the diagnostic workup of the acutely painful scrotum. All patients admitted between 1999 and 2005 with acute scrotal pain were included. After clinical assessment, patients were imaged by Doppler sonography with a ''high-end'' instrument. In cases of absent arterial perfusion of the testis in Doppler sonography, surgical exploration was carried out. Patients with unaffected perfusion were followed clinically by ultrasound for up to 2 years. Sixty-one infants and children aged 1 day to 17 years (median: 7.9 years) were included. In 14 cases, sonography demonstrated absent central perfusion, with abnormal parenchymal echogenicity in six. Absence of venous blood flow together with reduction of central arterial perfusion was found in one infant. In these 15 patients, surgical exploration confirmed testicular torsion. Among the other 46 patients, we found four cases with increased testicular perfusion and 27 with increased perfusion of the epididymis. In one infant, a testicular tumour was found sonographically, and orchiectomy confirmed diagnosis of a teratoma. Follow-up examinations of the conservatively treated patients showed good clinical outcome with physiologic central perfusion as well as normal echogenic pattern of both testes. No case of testicular torsion was missed. By means of Doppler sonography, an unequivocal statement regarding testicular perfusion was possible in all cases. The initial Doppler diagnosis was confirmed by operative evaluation and follow-up ultrasound. Testicular torsion can therefore be excluded by correctly performed ultrasound with modern equipment.

  6. Assessment of cutaneous radiation fibrosis by 20 MHz-sonography

    International Nuclear Information System (INIS)

    Gottloeber, P.; Braun-Falco, B.; Plewig, G.; Kerscher, M.; Peter, R.U.; Nadeshina, N.

    1996-01-01

    Radiation fibrosis is the cardinal symptom of the chronicle stage of the cutaneous radiation syndrome. The degree of cutaneous fibrosis can clinically be estimated by palpation. High-frequency 20 MHz-sonography is an established, noninvasive procedure, which renders an exact determination of skin thickness and additionally densitometry is possible. We investigated 15 survivors of the Chernobyl accident in 1986, who developed symptoms of the chronic stage of the cutaneous radiation syndrome. We determined skin thickness and echogenicity of skin areas clinically suggestive of radiation fibrosis before, during and after treatment. 20 MHz-sonography showed a distinct enlargement of the echorich corium and a reduction of the subcutaneous fatty tissue in comparison with the unaffected, contralateral skin, here demonstrating typical features of radiation fibrosis, namely dermal fibrosis and reactive pseudoatrophy and fatty tissue. The histology presented an increase and swelling of the collagen fibers and atypical fibroblastic cells. The patients received treatment with low-dose interferon y (Polyfcron R , 3 x 50μg s.C., three times per week) up to 30 months. A marked reduction of skin thickness and echogenicity reaching nearly normal values could be observed. We conclude that 20 MHz-sonography is an easy to apply, noninvasive, well established procedure to quantify cutaneous radiation fibrosis and to assess therapeutic outcome

  7. The value of computer tomography and sonography in the investigation of the pancreas

    International Nuclear Information System (INIS)

    Lackner, K.; Frommhold, H.; Grauthoff, H.; Moedder, U.; Heuser, L.; Braun, G.; Buurman, R.; Scherer, K.; Hamburg Univ.; Koeln Univ.

    1980-01-01

    Three hundred and five patients were examined by computer tomography and sonography. In 117 patients no abnormalities were found in the pancreas. The accuracy of computer tomography was 87%, of sonography 85%. In 41 patients the presence of a carcinoma of the pancreas was confirmed histologically. In this group the sensitivity of computer tomography was 83%, of sonography 85%. Thirty-four patients suffered from acute pancreatitis. In this group sensitivity of the two methods was equal at 79%. 113 patients had changes of chronic pancreatitis. Sensitivity of computer tomography was 84%, of sonography 70%. Computer tomography is better at demonstrating calcification in the pancreas. Atrophy of the pancreas cannot be diagnosed by sonography. (orig.) [de

  8. Language Lateralization in Children Using Functional Transcranial Doppler Sonography

    Science.gov (United States)

    Haag, Anja; Moeller, Nicola; Knake, Susanne; Hermsen, Anke; Oertel, Wolfgang H.; Rosenow, Felix; Hamer, Hajo M.

    2010-01-01

    Aim: Language lateralization with functional transcranial Doppler sonography (fTCD) and lexical word generation has been shown to have high concordance with the Wada test and functional magnetic resonance imaging in adults. We evaluated a nonlexical paradigm to determine language dominance in children. Method: In 23 right-handed children (12…

  9. Sonography in the 29th Olympic and Paralympic Games: a retrospective analysis.

    Science.gov (United States)

    He, Wen; Xiang, Dong-ying; Dai, Jian-ping

    2011-01-01

    The purpose of this study was to evaluate the application of sonography at the polyclinic of the Olympic/Paralympic village during the Olympic/Paralympic Games. We retrospectively reviewed 759 consecutive patients who underwent sonography at the ultrasound division of the polyclinic in the Olympic/Paralympic village from July 20, 2008, to September 20, 2008. Prevalence of emergency sonography after sports injury and non-sports-related urgent conditions during the games was analyzed. The benefit of sonographic services in large sporting events was discussed. There were 759 patients (484 athletes, 101 coaches, 88 team officials, and 86 volunteers; 462 men and 297 women) in the ultrasound division at the polyclinic. The indications for sonography included abdominal pain (315 cases, 41.50%), muskuloskeletal disorders (228 cases, 30.04%), gynecology related (104 cases, 13.70%), cardiac conditions (49 cases, 6.46%), small parts (29 cases, 3.82%), and vascular problems (34 cases, 4.48%). The rates of positive findings on sonography were 46.03% in the abdomen, 70.17% in musculoskeleton, 41.34% in gynecology, 10.20% in the heart, 75.86% in small parts, and 38.24% in vessels, respectively. Sonography plays an important role in the medical services at the polyclinic in the Olympic/Paralympic village. The benefits of sonography in such large sporting events are accuracy, fast result, portability, and noninvasiveness. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Diabetic mastopathy: a diagnostic challenge in breast sonography.

    Science.gov (United States)

    Moschetta, Marco; Telegrafo, Michele; Triggiani, Vincenzo; Rella, Leonarda; Cornacchia, Ilaria; Serio, Gabriella; Ianora, Amato Antonio Stabile; Angelelli, Giuseppe

    2015-02-01

    Our purpose was to retrospectively evaluate the incidence and morphologic features of diabetic mastopathy in a group of patients with diabetes, searching for specific sonographic characteristics of diabetic mastopathy. One hundred twenty diabetic patients underwent breast clinical examination, mammography, and sonography. All detected breast lesions were confirmed histopathologically. Breast lesions were found in 11 of the 120 patients (9%), including two cases of invasive ductal carcinomas and nine cases of diabetic mastopathy. In seven of those nine cases (77%), diabetic mastopathy appeared as a hypoechoic solid mass with irregular margins, inhomogeneous echotexture, and marked posterior shadowing. In the other two cases (23%), it appeared as a mildly inhomogeneous, hypoechoic solid mass. Diabetic mastopathy is a diagnostic challenge and needs to be suspected in all patients with diabetes mellitus. Imaging features are nonspecific and highly susggestive on breast sonography in most cases. Core-needle biopsy confirmation remains mandatory for a definitive diagnosis. © 2015 Wiley Periodicals, Inc.

  11. Role of sonography in the diagnosis of Echinococcus alveolaris

    Energy Technology Data Exchange (ETDEWEB)

    Maier, W.

    1983-02-01

    Abdominal sonography and computed tomography were performed in eleven patients with operatively and histologically proven Echinococcus alveolaris of the liver and the detailed appearances were compared. Sonography is a useful screening method in the assessment of E. alveolaris, but its previous importance is being gradually superseded by computed tomography, which is capable of providing more detailed information in the diagnosis of Echinococcus infestation.

  12. Clinical applications of imaging reconstruction by virtual sonography

    International Nuclear Information System (INIS)

    Mori, Akihiro; Oohashi, Noritsugu; Maruyama, Takako; Tatebe, Hideharu; Fushimi, Nobutoshi; Asano, Takayuki; Inoue, Hiroshi; Okuno, Masataka

    2008-01-01

    One of the pitfalls in managing multiple liver tumors is the difficulty in identifying individual tumors on ultrasonography. Computed tomography (CT)-assisted virtual sonography has been shown to improve sonographic diagnosis, however it requires additional equipment and software. We have developed a simple reconstruction method of virtual sonography (SRVS). We reconstructed SRVS mimicking ultrasonographic images, utilizing a workstation software attached to a multi-detector row CT system without any additional program. We have performed SRVS in 32 patients with 41 liver tumors that could hardly be identify on ultrasonography. SRVS assisted the identification of malignant form non-pathologic ones and thereby contributed to the appropriate clinical strategy including radiofrequency ablation (RFA) (18 tumors), liver biopsy (2 tumors), other therapies (4 tumors) and follow-up (17 tumors). We have developed virtual sonography using conventional CT software. SRVS seems useful in the clinical practice in managing liver tumors. (author)

  13. High resolution sonography of sublingual space

    International Nuclear Information System (INIS)

    Jain, P.

    2008-01-01

    Full text: Ultrasound examination of the sublingual region is a non-invasive, safe, inexpensive and widely available procedure, unaffected by the amalgam in teeth which is a source of considerable artefact on CT and MRI images. With a little practice and good understanding of the anatomy, ultrasound can be a very helpful primary examination. If the lesion is clearly seen, no further imaging may be required.

  14. High-resolution cranial ultrasound in the shaken-baby syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Chen, C.Y.; Chin, S.C.; Lee, C.C.; Lee, K.W. [Dept. of Radiology, Tri-Service General Hospital and National Defence Medical Centre, Taipei, Taiwan (Taiwan); Huang, C.C. [Dept. of Paediatrics, National Cheng Kung University Hospital, Tainan (Taiwan); Zimmerman, R.A. [Dept. of Radiology, Children' s Hospital of Philadelphia, PA (United States); Yuh, Y.S.; Chen, S.J. [Dept. of Paediatrics, Tri-Service General Hospital and National Defence Medical Centre, Neihu, Taipei (Taiwan)

    2001-08-01

    With limited near-field resolution and accessible acoustic windows, sonography has not been advocated for assessing central nervous system injuries in the shaken-baby syndrome. Our purpose was to correlate high-resolution ultrasonographic characteristics of central nervous system injuries in whiplash injuries and the shaken-baby-syndrome with MRI and CT. Ultrasonographic images of 13 infants, aged 2-12 months, with whiplash or shaking cranial trauma were reviewed and compared with MRI in 10 and CT in 10. Five patients had serial ultrasonography and MRI or CT follow-up from 1 to 4 months after the initial injury. With ultrasonography we identified 20 subdural haematomas. MRI and CT in 15 of these showed that four were hyperechoic in the acute stage, three were mildly echogenic in the subacute stage, and that one subacute and seven chronic lesions were echo-free. Five patients had acute focal or diffuse echogenic cortical oedema which evolved into subacute subcortical hyperechoic haemorrhage in four, and well-defined chronic sonolucent cystic or noncystic encephalomalacia was seen at follow-up in two. Using ultrasonography we were unable to detect two posterior cranial fossa subdural haematomas or subarachnoid haemorrhage in the basal cisterns in three cases, but did show blood in the interhemispheric cistern and convexity sulci in two. Ultrasonography has limitations in demonstrating abnormalities remote from the high cerebral convexities but may be a useful adjunct to CT and MRI in monitoring the progression of central nervous system injuries in infants receiving intensive care. (orig.)

  15. High-resolution cranial ultrasound in the shaken-baby syndrome

    International Nuclear Information System (INIS)

    Chen, C.Y.; Chin, S.C.; Lee, C.C.; Lee, K.W.; Huang, C.C.; Zimmerman, R.A.; Yuh, Y.S.; Chen, S.J.

    2001-01-01

    With limited near-field resolution and accessible acoustic windows, sonography has not been advocated for assessing central nervous system injuries in the shaken-baby syndrome. Our purpose was to correlate high-resolution ultrasonographic characteristics of central nervous system injuries in whiplash injuries and the shaken-baby-syndrome with MRI and CT. Ultrasonographic images of 13 infants, aged 2-12 months, with whiplash or shaking cranial trauma were reviewed and compared with MRI in 10 and CT in 10. Five patients had serial ultrasonography and MRI or CT follow-up from 1 to 4 months after the initial injury. With ultrasonography we identified 20 subdural haematomas. MRI and CT in 15 of these showed that four were hyperechoic in the acute stage, three were mildly echogenic in the subacute stage, and that one subacute and seven chronic lesions were echo-free. Five patients had acute focal or diffuse echogenic cortical oedema which evolved into subacute subcortical hyperechoic haemorrhage in four, and well-defined chronic sonolucent cystic or noncystic encephalomalacia was seen at follow-up in two. Using ultrasonography we were unable to detect two posterior cranial fossa subdural haematomas or subarachnoid haemorrhage in the basal cisterns in three cases, but did show blood in the interhemispheric cistern and convexity sulci in two. Ultrasonography has limitations in demonstrating abnormalities remote from the high cerebral convexities but may be a useful adjunct to CT and MRI in monitoring the progression of central nervous system injuries in infants receiving intensive care. (orig.)

  16. Sonography of the neonatal spine: part 1, Normal anatomy, imaging pitfalls, and variations that may simulate disorders.

    Science.gov (United States)

    Lowe, Lisa H; Johanek, Andrew J; Moore, Charlotte W

    2007-03-01

    Our objective is to discuss neonatal spine sonography with emphasis on imaging pitfalls and normal variants that may simulate disease and to distinguish them from true spinal disorders. Sonography of the neonatal spine is now accepted as a highly sensitive, readily available screening study that can be used to evaluate various anomalies of the lumbar spine in most infants younger than 4 months.

  17. Role of focused assessment with sonography for trauma as a ...

    African Journals Online (AJOL)

    Background: The objective of the study was to review the utility of focused assessement with sonography for trauma (FAST) as a screening tool for blunt abdominal trauma (BAT) in children involved in high energy trauma (HET), and to determine whether a FAST could replace computed tomography (CT) in clinical ...

  18. Sonography in the postoperative evaluation of laparoscopic inguinal hernia repair.

    Science.gov (United States)

    Furtschegger, A; Sandbichler, P; Judmaier, W; Gstir, H; Steiner, E; Egender, G

    1995-09-01

    We evaluated the use of sonography as a means of assessing hernial occlusion and possible postoperative changes such as hematomas or seromas in the inguinal and scrotal regions after 1139 laparoscopic repairs of hernias between August 1992 and November 1994. Changes after laparoscopic hernia repair were found in 307 patients (27%). Hematomas or seromas were seen in 132 patients, protrusion of the prosthetic mesh in 17, mesh infection in two, and small bowel entrapment in an insufficient peritoneal suture in two. Recurrences were diagnosed correctly in six patients, mobile preperitoneal lipomas in five. Sonography is useful in the evaluation of complications after laparoscopic hernia repair, including recurrent hernia. In the absence of symptoms, sonography is not indicated.

  19. Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips.

    Science.gov (United States)

    Schulz-Wendtland, R; Dankerl, P; Dilbat, G; Bani, M; Fasching, P A; Heusinger, K; Lux, M P; Loehberg, C R; Jud, S M; Rauh, C; Bayer, C M; Beckmann, M W; Wachter, D L; Uder, M; Meier-Meitinger, M; Brehm, B

    2015-01-01

    Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography.

  20. Principles and practice of sonography

    International Nuclear Information System (INIS)

    Fleischer, A.C.; James, A.E.

    1987-01-01

    This book is a text of sonographic technique, emphasizing clinical and diagnostic procedures. Ultrasound images and explanatory line drawings are placed side-by-side to facilitate interpretation. This book covers instrumentation and scanning principles, obstetric, gynecologic, abdominal, renal and urologic, pediatric, plus superficial structure sonography

  1. Reliability and precision of stress sonography of the ulnar collateral ligament.

    Science.gov (United States)

    Bica, David; Armen, Joseph; Kulas, Anthony S; Youngs, Kevin; Womack, Zachary

    2015-03-01

    Musculoskeletal sonography has emerged as an additional diagnostic tool that can be used to assess medial elbow pain and laxity in overhead throwers. It provides a dynamic, rapid, and noninvasive modality in the evaluation of ligamentous structural integrity. Many studies have demonstrated the utility of dynamic sonography for medial elbow and ulnar collateral ligament (UCL) integrity. However, evaluating the reliabilityand precision of these measurements is critical if sonography is ultimately used as a clinical diagnostic tool. The purpose of this study was to evaluate the reliability and precision of stress sonography applied to the medial elbow. We conducted a cross-sectional study during the 2011 baseball off-season. Eighteen National Collegiate Athletic Association Division I pitchers were enrolled, and 36 elbows were studied. Using sonography, the medial elbow was assessed, and measurements of the UCL length and ulnohumeral joint gapping were performed twice under two conditions (unloaded and loaded) and bilaterally. Intraclass correlation coefficients (0.72-0.94) and standard errors of measurements (0.3-0.9 mm) for UCL length and ulnohumeral joint gapping were good to excellent. Mean differences between unloaded and loaded conditions for the dominant arms were 1.3 mm (gapping; P < .001) and 1.4 mm (UCL length; P < .001). Medial elbow stress sonography is a reliable and precise method for detecting changes in ulnohumeral joint gapping and UCL lengthening. Ultimately, this method may provide clinicians valuable information regarding the medial elbow's response to valgus loading and may help guide treatment options. © 2015 by the American Institute of Ultrasound in Medicine.

  2. Afferent loop syndrome: Role of sonography and CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Ho; Lim, Jae Hoon; Ko, Young Tae [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1992-03-15

    Afferent loop syndrome(ALS) is caused by obstruction of the afferent loop after subtotal gastrectomy with Billroth II gastrojejunostomy. Prompt diagnosis of ALS is important as perforation of the loop occurs. The aim of study is to ascertain the sonography and CT to diagnose ALS. We describe the radiologic findings in ten patients with ALS. The cause of ALS, established at surgery, included cancer recurrence (n=4), internal hernia (n=4), marginal ulcer (n=1), and development of cancer at the anastomosis site (n=1). Abdominal X-ray and sonography were performed in all cases, upper GI series in five cases and computed tomography in two cases. The dilated afferent loop was detected in only two cases out often patients in retrospective review of abdominal X-ray. ALS with recurrence of cancer was diagnosed in three cases by upper GI series. Of the cases that had sonography, the afferent loop was seen in the upper abdomen crossing transversely over the midline in all ten patients. The cause of ALS were predicated on the basis of the sonograms in three of the five patients. In two cases of computed tomography, the dilated afferent loop and recurrent cancer at the remnant stomach were seen.Our experience suggests that the diagnosis of afferent syndrome can be made on the basis of the typical anatomic location and shape of the dilated bowel loop in both sonography and computed tomography.

  3. Role of focused assessment with sonography for trauma as a screening tool for blunt abdominal trauma in young children after high energy trauma

    NARCIS (Netherlands)

    Tummers, W.; Schuppen, J.V. (J Van); H.R. Langeveld-Benders (Hester); Wilde, J.; Banderker, E.; Van, A.

    2016-01-01

    textabstractBackground: The objective of the study was to review the utility of focused assessement with sonography for trauma (FAST) as a screening tool for blunt abdominal trauma (BAT) in children involved in high energy trauma (HET), and to determine whether a FAST could replace computed

  4. Re-Appraising the Role of Sonography in Pediatric Acute Abdominal Pain

    OpenAIRE

    Lin, Wei-Ching; Lin, Chien-Heng

    2013-01-01

    Objective Most pediatric emergency department (ED) visits are due to acute abdominal pain. Sonography is a reliable technique for differential diagnosis. The objective of this study was to re-appraise the role of sonography in evaluating acute abdominal pain in children. Methods Retrospective chart review of children aged

  5. Role of focused assessment with sonography for trauma as a screening tool for blunt abdominal trauma in young children after high energy trauma

    NARCIS (Netherlands)

    Tummers, W.; van Schuppen, J.; Langeveld, H.; Wilde, J.; Banderker, E.; van As, A.

    2016-01-01

    The objective of the study was to review the utility of focused assessement with sonography for trauma (FAST) as a screening tool for blunt abdominal trauma (BAT) in children involved in high energy trauma (HET), and to determine whether a FAST could replace computed tomography (CT) in clinical

  6. Transabdominal bowl sonography

    DEFF Research Database (Denmark)

    Wilkens, Rune; Strandberg, Charlotte

    2014-01-01

    This focused review describes the current use and future perspectives regarding transabdominal bowel sonography (TABS). The technique for B-mode and Doppler is described and the use of ultrasound contrast and elastography is discussed. Pathology and subsequent imaging findings are focused on appe...... on appendicitis, diverticulitis, inflammatory bowel diseases and within paediatric conditions along with other common intestinal pathology. In conclusion we find that TABS is a fast, efficient, low-cost and non-ionization imaging technique without any patient discomfort....

  7. The efficiency of sonography in diagnosing volvulus in neonates with suspected intestinal malrotation.

    Science.gov (United States)

    Zhang, Wenhua; Sun, Hongjun; Luo, Fangqiong

    2017-10-01

    This study is to prospectively evaluate the efficiency of sonography for volvulus diagnosis in neonates with clinically suspected intestinal malrotation.A total of 83 patients with suspected intestinal malrotation who underwent detailed abdominal sonography and upper gastrointestinal contrast study were included. Malrotation was characterized by inversion of the superior mesenteric artery (SMA) and superior mesenteric vein (SMV) in sonographic examination. The "whirlpool sign" of Color Doppler Sonography was recognized as a characteristic for malrotation with volvulus. The degrees of rotation of the SMV winding around SMA were also detected by sonography. Surgery was performed in patients with sonography diagnosed malrotation.A total of 39 patients were sonographically diagnosed as malrotation which was subsequently confirmed by surgery. The sensitivity and positive predictive value of the sonographic diagnosis were both 100% (39/39). The sensitivity, specificity and accuracy of "whirlpool sign" for the detection of midgut volvulus were 95.2% (20/21), 88.9% (16/18), and 92.3% (36/39), respectively. Greater degrees of rotation (equal or greater than 720°) showed higher risk (odds ratio, 5.0; P volvulus may be used as a potential indicator for intestinal necrosis. In addition, sonography can exclude malrotation and may help the diagnosis of other diseases, such as annular pancreas and duodenal atresia.

  8. Malignant and benign diseases of the breast in 41 male patients: mammography, sonography and pathological correlations; Maligne und benigne Erkrankungen der Brust bei 41 maennlichen Patienten: Mammographie und Sonographie mit histopathologischer Korrelation

    Energy Technology Data Exchange (ETDEWEB)

    Partik, B.; Mallek, R.; Pokieser, P.; Wunderbaldinger, P.; Helbich, T.H. [Vienna Univ. (Austria). Klinik fuer Radiodiagnostik; Rudas, M. [Vienna Univ. (Austria). Inst. fuer Klinische Pathologie

    2001-11-01

    Aim: The goal of our study was to evaluate findings in mammography and sonography in male patients with pathohistologically proven diseases of the breast. Material and Methods: Mammographies and sonographies, which were obtained in 41 male patients in a 6-year period, were retrospectively evaluated in accordance with the BI-RADS trademark classification. Results: Histologically 13 carcinomas, 21 gynecomastias, 3 pseudogynecomastias, 2 epithelial inclusion cysts and 2 other benign lesions were diagnosed. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of mammography in differentiation of benign versus malignant disease were 92%, 89%, 80%, 96% and 90%, respectively. Additional sonography did not change these results. However, sonography increased diagnostic confidence in 18.2% (2/11) of suspicious lesions. Conclusion: In our study the invasive ductal carcinoma of male patients was a predominantly lobulated, ill-defined lesion in mammography and sonography. The differentiation of carcinoma to pseudogynecomastia and diffuse or dendritic gynecomastia was securely feasible. However, we could not reliably distinguish between carcinoma and some benign mass lesions. In cases of mammographically diagnosed masses or unclear mammography, additional sonography should be performed to increase the diagnostic confidence. (orig.) [German] Ziel: Die Befunde von Mammographie und Sonographie bei histologisch gesicherten malignen und benignen Mammaerkrankungen maennlicher Patienten zu evaluieren. Material und Methode: Retrospektiv wurden die in einem Zeitraum von 6 Jahren durchgefuehrten Mammographien und Sonographien bei 41 maennlichen Patienten in Anlehnung an die BI-RADS trademark Klassifikation ausgewertet. Resultate: Es wurden 13 Karzinome, 21 Gynaekomastien, 3 Pseudogynaekomastien, 2 Atherome und 2 weitere benigne Laesionen histologisch diagnostiziert. Die Mammographie zeigte in der Differenzierung maligne versus benigne Laesion

  9. The role of sonography in the diagnosis of Echinococcus alveolaris

    International Nuclear Information System (INIS)

    Maier, W.

    1983-01-01

    Abdominal sonography and computed tomography were performed in eleven patients with operatively and histologically proven Echinococcus alveolaris of the liver and the detailed appearances were compared. Sonography is a useful screening method in the assessment of E. alveolaris, but its previous importance is being gradually superseded by computed tomography, which is capable of providing more detailed information in the diagnosis of Echinococcus infestation. (orig.)

  10. Radiofrequency ablation assisted by real-time virtual sonography for hepatocellular carcinoma inconspicuous under sonography and high-risk locations

    Directory of Open Access Journals (Sweden)

    Cheng-Han Lee

    2015-08-01

    Full Text Available Radiofrequency ablation (RFA is an effective and real-time targeting modality for small hepatocellular carcinomas (HCCs. However, mistargeting may occur when the target tumor is confused with cirrhotic nodules or because of the poor conspicuity of the index tumor under ultrasonography (US. Real-time virtual sonography (RVS can provide the same reconstruction computed tomography images as US images. The aim of this study is to investigate the usefulness of RVS-assisted RFA for HCCs that are inconspicuous or conspicuous under US. A total of 21 patients with 28 HCC tumors—divided into US inconspicuous and high-risk subgroup (3 tumors in 3 patients, US inconspicuous and nonhigh-risk subgroup (5 tumors in 4 patients, US conspicuous and high-risk subgroup (16 tumors in 14 patients, and US conspicuous and nonhigh-risk subgroup (4 tumors in 3 patients—underwent RVS-assisted RFA between May 2012 and June 2014 in our institution. The mean diameter of the nodules was 2.0 ± 1.1 cm. The results showed that the complete ablation rate is 87.5% (7/8 in the US undetectable group and 75% (15/20 in the US detectable group. A comparison between six tumors with incomplete ablation and 22 tumors with complete ablation showed higher alpha-fetoprotein level (mean, 1912 ng/mL vs. 112 ng/mL and larger tumor size (mean diameter, 26 mm vs. 16 mm in the incomplete ablation nodules (both p < 0.05. In conclusion, RVS-assisted RFA is useful for tumors that are difficult to detect under conventional US and may also be useful for tumors in high-risk locations because it may prevent complication induced by mistargeting.

  11. Management of threatened abortion with real-time sonography.

    Science.gov (United States)

    Anderson, S G

    1980-02-01

    Real-time sonography was used to evaluate 158 patients with threatened abortion. Fetal motion was first detected during the seventh gestational week and with increasing frequency thereafter in 73 patients with viable pregnancies continuing to term. Only 2 of 65 patients who aborted demonstrated fetal motion. The presence or absence of fetal motion was most reliable after 7 weeks' gestation for establishing a prognosis for a given pregnancy. Seventy-two of 74 pregnancies with fetal motion continued to term, whereas 63 of 64 pregnancies without fetal motion aborted. A method for using real-time sonography in the management of threatened abortion is presented.

  12. Using modern teaching strategies to teach upper abdominal sonography to medical students.

    Science.gov (United States)

    Cheng, Wei-Chun; Lin, Xi-Zhang; Chen, Chiung-Yu

    2013-07-01

    Upper abdominal sonography can help physicians to confirm the diagnosis of various hepatobiliary diseases. Teaching sonography skills to medical students is important because it may enhance their level of knowledge and overall development during their gastroenterology section rotation. Sonographic imaging is abstract and students can be easily confused when scanning the abdominal structures from different sites and directions. We used several modern teaching strategies to facilitate the learning of sonography skills. The year five medical students beginning a gastroenterology section rotation for their first-year clerkship were taught abdominal sonography skills. Abstract sonographic images were related to concrete objects and the surrounding structures were further indicated. Each of the images was given a specific name and was sorted according to the scanning site. A mnemonics system was designed to help students to memorize the names of these images. A badge was created to recognize the achievement of being able to complete a basic upper abdominal sonography. Students were free (i.e., not obligated) to request a demonstration opportunity to show their skills within 2 weeks after receiving tutelage. We recorded the number of students who received training and were able to successfully complete the task; these individuals then received a badge to be pinned onto their white coats. Sixty-three of 68 students (92.6%) requested evaluation and all of them passed. We have greatly simplified the process of learning about upper abdominal sonography by using andragogy to enhance learning, mnemonics to help memory, and a pin-badge reward system to stimulate incentives. Copyright © 2013. Published by Elsevier B.V.

  13. Biopsy guided by real-time sonography fused with MRI: a phantom study

    DEFF Research Database (Denmark)

    Ewertsen, C.; Grossjohann, Hanne Sønder; Nielsen, Kristina Rue

    2008-01-01

    OBJECTIVE: The purpose of our study was to test the accuracy of sonographically guided biopsies in a phantom of structures not visible on sonography but shown on MRI by using commercially available sonography systems with image fusion software. MATERIALS AND METHODS: A previously recorded MRI...

  14. Duplex sonography of the near-surface leg veins; Duplexsonographie der oberflaechlichen Beinvenen

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, E.

    2007-07-01

    The book contains the following contributions: The ultrasonograph, selection of the ultrasonic transducer, anatomy of the near-surface vein system, physiology of the near-surface vein system, varicose status classification, systematics of the duplex sonography of near-surface leg veins, provocational maneuver for the duplex sonographic varicose diagnostics, exploration of vena saphena parva, perforans veins, side branches, phlebitis, sonography for varicose therapy, postsurgical sonography, deep leg veins, examination of near-surface leg veins for the pathology of the deep vein system, differential diagnostic clarification of leg oedema from the phlebologic-lymphological view, diagnostic side features along the near-surface leg veins.

  15. The demonstration of gall stones by sonography and radiography

    International Nuclear Information System (INIS)

    Gladisch, R.; Deininger, H.K.; Staedtische Kliniken Darmstadt

    1983-01-01

    Eighty-seven unselected gall stones were examined radiologically and by ultrasound in vitro. No relationship of diagnostic value could be established between the amount of calcification and stone demonstration, the sonogram being influenced by the size of the stone, its surface contour and its position in the ultrasound beam. Sonography is therefore not suitable for selecting those patients on whom litholysis could be carried out. Sonography appears to be useful only in a negative way by establishing the exact size of the concretion. (orig.) [de

  16. Radiology of the male breast. Radiologische Diagnostik der maennlichen Brustdruese. Mammographie, Sonographie, pathohistologische Korrelation

    Energy Technology Data Exchange (ETDEWEB)

    Buchberger, W; Penz, T; Strasser, K [Innsbruck Univ. (Austria). Universitaetsklinik fuer Radiodiagnostik; Toetsch, M [Innsbruck Univ. (Austria). Inst. fuer Pathologische Anatomie

    1991-09-01

    61 men with breast enlargement underwent mammography; complementary sonography was performed in 34 cases. Diagnoses included gynaecomastia in 53 cases, pseudogynaecomastia in 9 cases, 3 carcinomas, 2 inflammatory lesions and 1 lipoma. Mammography and sonography can differentiate reliably true gynaecomastia from pseudogynaecomastia. Gynaecomastia and especially inflammatory lesions may not always be readily differentiated from carcinoma. Sonography can be helpful by demonstrating hyperreflexive glandular tissue, whereas carcinomas are usually hypoechoic. (orig./GDG).

  17. Central venous cannulation: are routine chest radiographs necessary after B-mode and colour Doppler sonography check?

    International Nuclear Information System (INIS)

    Lanza, Cecilia; Fabrizzi, Giancarlo; Russo, Marco

    2006-01-01

    After the insertion of a central venous catheter, a chest radiograph is usually obtained to ensure correct positioning of the catheter tip. To determine in a paediatric population whether B-mode and colour Doppler sonography after central venous access is useful to evaluate catheter position, thus obviating the need for a postprocedural radiograph. A prospective study of 107 consecutive central venous access procedures placed in a paediatric intensive care unit was performed. At the end of the procedure, B-mode and colour Doppler sonography were used to assess catheter position and check for complications. A postprocedural chest radiograph was obtained in all patients. In 96 patients postprocedural B-mode and colour Doppler sonography showed colour Doppler signals within the vena cava. Among the 11 patients predicted to have a potential complication, there was one pneumothorax and ten malpositions. Chest radiography showed a total of 13 complications - 1 pneumothorax and 12 malpositions. The concordance between colour Doppler sonography and chest radiography was 98.1% in the detection of catheter position; sonography had a sensitivity of 84.6% and a specificity of 100%. The close concordance between B-mode and colour Doppler sonography and chest radiography justifies the more frequent use of sonography to evaluate catheter position because ionizing radiation is eliminated. Chest radiography may then be performed only when there is suspected inappropriate catheter tip position after sonography. (orig.)

  18. Sonography, CT and MR in soft part growths in the head and neck region

    International Nuclear Information System (INIS)

    Brinkmann, G.; Brix, F.; Beigel, A.

    1990-01-01

    14 patients with a space-occupying growth in the head and neck region were examined via sonography, CT and MR to explore and demonstrate by means of a prospective comparative study the possibilities offered by these three imaging methods. Stages are best diagnosed by means of sonography; the leading role of this method is undisputed. To clarify sonographically unclear findings and especially in pre-surgery planning, MR offers advantages over CT on account of the high soft-part contrast and multiplanar visualisation. However, it is impossible or very difficult to differentiate abscesses and lymphadenitides from malignant growths with these three methods solely on the basis of image-morphological criteria. (orig.) [de

  19. Diagnosis of hydronephrosis: comparison of radionuclide scanning and sonography

    International Nuclear Information System (INIS)

    Malave, S.R.; Neiman, H.L.; Spies, S.M.; Cisternino, S.J.; Adamo, G.

    1980-01-01

    Diagnostic sonographic and radioisotope scanning techniques have been shown to be useful in the diagnosis of obstructive uropathy. The accuracy of both methods was compared and sonography was found to provide the more accurate data (sensitivity, 90%, specificity, 98%; accuracy, 97%). Sonography provides excellent anatomic information and enables one to grade the degree of dilatation. Renal radionuclide studies were less sensitive in detecting obstruction, particularly in the presence of chronic renal disease, but offered additional information regarding relative renal blood flow, total effective renal plasma flow, and interval change in renal parenchymal function

  20. Ideal Positions: 3D Sonography, Medical Visuality, Popular Culture.

    Science.gov (United States)

    Seiber, Tim

    2016-03-01

    As digital technologies are integrated into medical environments, they continue to transform the experience of contemporary health care. Importantly, medicine is increasingly visual. In the history of sonography, visibility has played an important role in accessing fetal bodies for diagnostic and entertainment purposes. With the advent of three-dimensional (3D) rendering, sonography presents the fetus visually as already a child. The aesthetics of this process and the resulting imagery, made possible in digital networks, discloses important changes in the relationship between technology and biology, reproductive health and political debates, and biotechnology and culture.

  1. An economic evaluation of first-trimester genetic sonography for prenatal detection of Down syndrome.

    Science.gov (United States)

    Vintzileos, A M; Ananth, C V; Fisher, A J; Smulian, J C; Day-Salvatore, D; Beazoglou, T

    1998-04-01

    To determine 1) the diagnostic accuracy requirements of first-trimester genetic sonography from the cost-benefit point of view and 2) the economic impact of first-trimester genetic sonography for the United States on the basis of the accuracy of previously published studies. A cost-benefit equation was developed on the basis of the hypothesis that the cost of chorionic villus sampling (CVS) in pregnant women with advanced maternal age (at least 35 years old) should be at least equal to the cost of genetic sonography with CVS used only for those with abnormal ultrasound results. The components of the equation included the diagnostic accuracy of genetic ultrasound (sensitivity and specificity for detecting Down syndrome), the costs of the CVS package and genetic ultrasound, and the lifetime cost of Down syndrome cases. First-trimester genetic sonography was found to be beneficial if the overall sensitivity for detecting Down syndrome was greater than 70%, and even then, the cost-benefit ratio depended on the corresponding false-positive rate. The required minimum ultrasound sensitivity varied according to the maternal age-specific prevalence of Down syndrome and ranged between 40% (for women 35 years old) to 96% (for women 44 years old). Of eight published cohorts using nuchal translucency thickness for genetic sonography, five had accuracies of genetic ultrasound compatible with net benefits. The benefits of first-trimester genetic sonography depend on its diagnostic accuracy. First-trimester genetic sonography has the potential for annual savings of 22 million dollars in the United States.

  2. Women's perception of transvaginal sonography in a tertiary hospital in nigeria

    International Nuclear Information System (INIS)

    Eze, C.U.; Okaro, A.O.; Nwobi, I.C.

    2008-01-01

    Available studies suggest that pregnant women's views on the desirability of routine ultrasound are Influenced by their perceptions of its potential benefits and concern about possible adverse effects. To assess women's views of transvaginal sonography and to determine any correlation between their perception of the procedure and their prior knowledge and experience of it. We surveyed women presenting with various gynecologic problems or complications of the first trimester. Data collection was by self-administered questionnaires using conveniences sampling technique on women attending the clinic over a period of one year. Only women who had transvaginal sonography were included. A total of 250 women were recruited and interviewed. Transvaginal sonography was considered not embarrassing by 76%, acceptable by 86%, not painful by 87.2% and not stressful by 82% of the women. There were no statistically significant differences in the women's perception of the procedure whether they had prior knowledge and previous experience of the procedure or not (P>0.05). The majority of the women perceived transvaginal sonography favourably. Their perception of the Procedure was favourable whether they had prior knowledge and previous experience of it or not. (author)

  3. Deginerative changes of femoral articular cartilage in the knee : comparative study of specimen sonography and pathology

    International Nuclear Information System (INIS)

    Park, Ju Youn; Hong, Sung Hwan; Sohn, Jin Hee; Wee, Young Hoon; Chang, Jun Dong; Park, Hong Seok; Lee, Eil Seoung; Kang Ik Won

    2001-01-01

    To determine the sonographic findings of degenerative change in femoral articular cartilage of the knee by comparative study of specimen sonography and pathology. We obtained 40 specimens of cartilage of the femur (20 medial and 20 lateral condylar) from 20 patients with osteoarthritis of the knee who had undergone total knee replacement. The specimens were placed in a saline-filled container and sonography was performed using a 10-MHz linear transducer. Sonographic abnormalities were evaluated at the cartilage surface, within the cartilage, and at the bone-cartilage interface, and were compared with the corresponding pathologic findings. In addition, cartilage thickness was measured at a representative portion of each femoral cartilage specimen and was compared with the thickness determined by sonography. 'Dot' lesions, irregularity or loss of the hyperechoic line, were demonstrated by sonography at the saline-cartilage interface of 14 cartilages. Pathologic examination showed that these findings corresponded to cleft, detachment, erosion, and degeneration. Irregularities in the hyperechoic line at the bone-cartilage interface were revealed by sonography in eight cartilages and were related to irregularity or loss of tidemark, downward displacement of the cartilage, and subchondral callus formation. Dot lesions, corresponding to cleft and degeneration, were noted within one cartilage. Cartilage thickness measured on specimen and by sonography showed no significant difference (p=0.446). Specimen sonography suggested that articular cartilage underwent degenerative histopathological change. Cartilage thickness measured by sonography exactly reflected real thickness

  4. Sonography as a new diagnostic procedure for investigating abnormalities of the shoulder

    International Nuclear Information System (INIS)

    Rapf, C.; Furtschegger, A.; Resch, H.; Innsbruck Univ.

    1986-01-01

    Eighty-one sonographic examinations of patients with complaints relating to the shoulder joint have shown that this is the method next in value to radiological examination. So far, lesions of the rotator cuff and of the long head of the biceps could only be demonstrated by invasive procedures such as arthrography or arthroscopy. In these situations, sonography attains a similar accuracy. Diffuse lesions can also be diagnosed correctly, making arthrography and arthroscopy unnecessary. In addition, sonography can demonstrate inflammatory and degenerative changes and incomplete sub-acromial and intermediary tears of the rotator cuff, unlike conventional diagnostic methods. In future, arthrography and arthroscopy will only be necessary as additional diagnostic methods if sonography remains inconclusive. (orig.) [de

  5. Stress Urinary lncontinence : Comparative Study of Perineal Sonography in Erect Position and Chain Cystourethrograpy

    Energy Technology Data Exchange (ETDEWEB)

    Han, Gi Seok; Kim, Seung Hyup; Yeon, Kyung Mo; Han, Man Chung; Paick, Jae Seung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1995-06-15

    Authors investigated the diagnostic value of perineal sonography in erect position for patients with stress urinary incontinence. Perineal sonography and chain cystourethrography were performed in 18 female patients(mean age 51.2) with stress urinary incontinence. The posterior are throvesical angles in stress and rest states were measured in both studies and compared with each other. Mean posteriorurethrovesical angles({+-}2 standard error) in rest and stress states were 136.3({+-}7.2) .deg. , and 145.9({+-}7.0) .deg. for chain cystourethrography and 131.4({+-}5.6) .deg. and 143.4({+-}5.9) .deg. for perineal sonography, respectively. The data frorm both studies correlated well with cach other. Perineal sonography inerect position is easy,non-invasive technique and may substitute the chain cystourethrography in the evaluation of the patients with stress urinary in continece

  6. Retrobulbar Hematoma from Warfarin Toxicity and the Limitations of Bedside Ocular Sonography

    Science.gov (United States)

    2010-05-01

    worldwide. Peer Reviewed Title: Retrobulbar Hematoma from Warfarin Toxicity and the Limitations of Bedside Ocular Sonography Journal Issue: Western...Preferred Citation: Thompson D, Stanescu C, Pryor P, Laselle B. Retrobulbar Hematoma from Warfarin Toxicity and the Limitations of Bedside Ocular...nontrauamtic retrobulbar hematoma associated with warfarin toxicity. The application and limitations of focused bedside ocular sonography for this

  7. Transcranial Doppler sonography in familial hemiplegic migraine

    International Nuclear Information System (INIS)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A.

    1991-01-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab

  8. Transcranial Doppler sonography in familial hemiplegic migraine

    Energy Technology Data Exchange (ETDEWEB)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A. (Universita la Sapienza, Roma (Italy))

    1991-02-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab.

  9. Three-dimensional versus two-dimensional sonography of the temporomandibular joint in comparison to MRI

    Energy Technology Data Exchange (ETDEWEB)

    Landes, Constantin A. [Oral, Maxillofacial and Plastic Facial Surgery, Frankfurt University Medical Centre, Theodor-Stern-Kai 7, 60596 Frankfurt (Germany)]. E-mail: c.landes@lycos.com; Goral, Wojciech A. [Oral, Maxillofacial and Plastic Facial Surgery, Frankfurt University Medical Centre, Theodor-Stern-Kai 7, 60596 Frankfurt (Germany)]. E-mail: w.goral@gmx.de; Sader, Robert [Oral, Maxillofacial and Plastic Facial Surgery, Frankfurt University Medical Centre, Theodor-Stern-Kai 7, 60596 Frankfurt (Germany)]. E-mail: r.sader@em.uni-frankfurt.de; Mack, Martin G. [Department of Diagnostic and Interventional Radiology, Frankfurt University Medical Centre, Theodor-Stern-Kai 7, 60596 Frankfurt (Germany)]. E-mail: martinmack@arcor.de

    2007-02-15

    Aim: To compare clinical feasibility of static two-dimensional (2D) to three-dimensional (3D) sonography of the temporomandibular joint (TMJ) in assessment of disk dislocation and joint degeneration compared to magnetic resonance imaging (MRI). Method: Thirty-three patients, 66 TMJ were prospectively sonographed 2D and 3D (8-12.5 MHz step motor scan), in occlusion and maximum opening with a probe position parallel inferior to the zygomatic arch. Axial 2D images were judged independent from the 3D scans; 3D volumes were cut axial, sagittal, frontal and rotated in real-time. Disk position and joint degeneration were assessed and compared to a subsequent MRI examination. Results: The specific appearance of the disk was hypoechogenic overlying a hyperechogenic condyle in axial (2D) or sagittal and frontal (3D) viewing. Specificity of 2D sonography for disk dislocation was 63%, sensitivity 58%, accuracy 64%, positive predictive value 46%, negative predictive value 73%; for joint degeneration synonymously 59/68/61/38/83%. 3D sonography for disk displacement reached synonymously 68/60/69/51/76%, for joint degeneration 75/65/73/48/86%. 2D sonographic diagnoses of disk dislocation in the closed mouth position and of joint degeneration showed significantly different results from the expected values (MRI) in {chi} {sup 2} testing; 3D diagnoses of disk dislocation in closed mouth position, of joint degeneration, 2D and 3D diagnoses in open mouth position were nonsignificant. Conclusions: Acceptable was the overall negative predictive value, as specificity and accuracy for joint degeneration in 3D. 3D appears superior diagnosing disk dislocation in closed mouth position as for overall joint degeneration. Sensitivity, accuracy and positive predictive value will have to ameliorate with future equipment of higher resolution in real-time 2D and 3D, if sonographic screening shall be clinically applied prior to MRI.

  10. Fetal tracheolaryngeal airway obstruction: prenatal evaluation by sonography and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Courtier, Jesse; Poder, Liina; Wang, Zhen J.; Westphalen, Antonio C.; Yeh, Benjamin M.; Coakley, Fergus V. [University of California San Francisco, Department of Radiology, San Francisco, CA (United States)

    2010-11-15

    We reviewed the sonographic and MRI findings of tracheolaryngeal obstruction in the fetus. Conditions that can cause tracheolaryngeal obstruction include extrinsic causes such as lymphatic malformation, cervical teratoma and vascular rings and intrinsic causes such as congenital high airway obstruction syndrome (CHAOS). Accurate distinction of these conditions by sonography or MRI can help facilitate parental counseling and management, including the decision to utilize the ex utero intrapartum treatment (EXIT) procedure. (orig.)

  11. Evaluation of renal allograft rejection by Doppler sonography and MR imaging

    International Nuclear Information System (INIS)

    Steinberg, H.V.; Nelson, R.C.; Murphy, F.B.; Baumgartner, B.R.; Bourke, E.; Delaney, V.B.; Whelchel, J.B.; Bernardino, M.E.

    1986-01-01

    The authors prospectively studies the efficacy of Doppler sonography and MR imaging in evaluating renal allografts, with specific attention to transplant rejection. Based on study findings, we were unable to make a statement with respect to the appearance or accuracy of diagnosing cyclosporin toxicity or acute tubular necrosis by either modality due to concomitant rejection in the few patients so afflicted. Moreover, the ability to predict and diagnose the presence or absence of allograft rejection was not affected by different serum creatinine values. Most important, however, Doppler sonography was shown to be superior to MR imaging in evaluating for allograft rejection, as evidenced by its higher sensitivity (100% vs. 71%), specificity (88% vs. 75%), and accuracy (96% vs. 73%). Thus, because of its low cost and ease of accessibility, Doppler sonography should become the primary modality for renal transplant screening

  12. Stress Urinary lncontinence : Comparative Study of Perineal Sonography in Erect Position and Chain Cystourethrograpy

    International Nuclear Information System (INIS)

    Han, Gi Seok; Kim, Seung Hyup; Yeon, Kyung Mo; Han, Man Chung; Paick, Jae Seung

    1995-01-01

    Authors investigated the diagnostic value of perineal sonography in erect position for patients with stress urinary incontinence. Perineal sonography and chain cystourethrography were performed in 18 female patients(mean age 51.2) with stress urinary incontinence. The posterior are throvesical angles in stress and rest states were measured in both studies and compared with each other. Mean posteriorurethrovesical angles(±2 standard error) in rest and stress states were 136.3(±7.2) .deg. , and 145.9(±7.0) .deg. for chain cystourethrography and 131.4(±5.6) .deg. and 143.4(±5.9) .deg. for perineal sonography, respectively. The data frorm both studies correlated well with cach other. Perineal sonography inerect position is easy,non-invasive technique and may substitute the chain cystourethrography in the evaluation of the patients with stress urinary in continece

  13. Intratumoral vascularity of experimentally induced VX2 carcinoma : comparison of power doppler sonography and microangiography

    International Nuclear Information System (INIS)

    Park, Kil Sun; Won, Hyung Jin; Seo, Joon Beom; Kim, Tae Kyoung; Han, Joon Koo; Choi, Byung Ihn

    1997-01-01

    To evaluate the usefulness and limitations of power Doppler sonography in determining the tumor vascularity Power Doppler sonography was performed on VX2 carcinomas present in rabbit thighs, and the findings were compared with those of microangiography in an almost identical plane. Tumor vascularity was qualitatively analysed on the basis of tumor vessel distribution and density, and the presence of thick and thin vesels;for a comparison of tumor vascularity as seen on microangiography, tumor blood flow signals shown by power Doppler sonography were graded 3, 2, 1, 0. For quantitative analysis, a comparison was made of the percentage of tumor area occupied by vessels, as shown in each study. Data analysis utilized the Wilcoxon signed-rank test and Spearman correlation test. Mean tumor vascularity scores, as seen on power Doppler sonography and relating to tumor vessel distribution and density, and the presence of thick and thin vessels, were 2.87, 2.73, 2.93 and 2.73, respectively. The means and medians of the percentages of tumor area occupied by vessels were 22.7% and 23.5% and 36.4% and 34.7% on microangiography and power Doppler sonography, respectively. Thus, there was good correlation between these two modes. Power doppler sonography could demonstrate the tumor vascularity on microangiography relatively well but tend to overestimate it

  14. Fetal tracheolaryngeal airway obstruction: prenatal evaluation by sonography and MRI

    Science.gov (United States)

    Courtier, Jesse; Poder, Liina; Wang, Zhen J.; Westphalen, Antonio C.; Yeh, Benjamin M.

    2010-01-01

    We reviewed the sonographic and MRI findings of tracheolaryngeal obstruction in the fetus. Conditions that can cause tracheolaryngeal obstruction include extrinsic causes such as lymphatic malformation, cervical teratoma and vascular rings and intrinsic causes such as congenital high airway obstruction syndrome (CHAOS). Accurate distinction of these conditions by sonography or MRI can help facilitate parental counseling and management, including the decision to utilize the ex utero intrapartum treatment (EXIT) procedure. PMID:20737145

  15. The cardiac sonography workforce in New Zealand

    Science.gov (United States)

    White, Steve; Poppe, Katrina; Whalley, Gillian

    2015-01-01

    Abstract Introduction: The aim of this paper is to investigate the cardiac sonography workforce characteristics and registration requirements in New Zealand (NZ), with a comparison to similar workforces internationally. Methods: The Survey of Clinical Echocardiography in New Zealand 2 (SCANZ2) audit was performed in December 2010. All of NZ's public‐funded District Health Board (DHB) centers providing echocardiography services responded to questions relating to staff, equipment, procedure types and patient statistics. The Medical Radiation Technologists Board (MRTB), Clinical Physiologists Registration Board (CPRB) and Australian Sonographers Association Registry (ASAR) websites were reviewed in March 2012 for registered sonographers with a cardiac scope of practice. The cardiac sonography workforces in Australia, the UK, the USA and Canada were investigated for comparison. Results: There are 84 cardiac sonographers (60.3 full‐time equivalent) working in DHBs: 71% from a cardiac technical background; 40% have post‐graduate qualifications; a further 17% are undertaking post‐graduate qualifications; and 59 cardiac sonographers have registration with professional bodies in NZ and/or Australia. Cardiac sonographers in NZ do not undergo compulsory registration, but other sonographers in NZ have compulsory registration with the MRTB. Sonographers are predominantly not licensed internationally. Discussion: Disparity exists between registration of cardiac and non‐cardiac sonographers in NZ. Many cardiac sonographers have voluntary registration but few are registered with the MRTB. Reasons for this include professional alignment, educational qualifications and representation. International trends show increased pressure from governments and professional bodies to regulate sonographers. Conclusion: This study provides a snapshot of the cardiac sonography workforce in NZ for the first time. PMID:28191178

  16. Three-dimensional power Doppler sonography: imaging and quantifying blood flow and vascularization.

    Science.gov (United States)

    Pairleitner, H; Steiner, H; Hasenoehrl, G; Staudach, A

    1999-08-01

    To assess the feasibility of imaging low-velocity blood flow in adnexal masses by transvaginal three-dimensional power Doppler sonography, to analyze three-dimensional power Doppler sonography data sets with a new computer-assisted method and to test the reproducibility of the technique. A commercially available 5-MHz Combison 530 ultrasound system was used to perform three-dimensional power Doppler sonography transvaginally. A cube (= volume of interest) was defined enclosing the vessels of the cyst and the Cartesian characteristics were stored on a hard disk. This cube was analyzed using specially designed software. Five indices representing vascularization (the vascularization index (VI) or blood flow (the flow index (FI)) or both (the vascularization-flow index (VFI)) were calculated. The intraobserver repeatability of cube definition and scan repetition was assessed using Hartley's test for homogeneous variances. Interobserver agreement was assessed by the Pearson correlation coefficient. Imaging of vessels with low-velocity blood flow by three-dimensional power Doppler sonography and cube definition was possible in all adnexal massed studied. In some cases even induced non-vascular flow related to endometriosis was detected. The calculated F value with intraobserver repeated Cartesian file-saving ranged from 0 to 18.8, with intraobserver scan repetition from 4.74 to 24.8 for VI, FI 1, FI 2 and VFI 1; for VFI 2 the calculated F value was 64. The interobserver correlation coefficient ranged between 0.83 and 0.92 for VI, FI 1, FI 2 and VFI 1; for VFI 2 the correlation coefficient was less than 0.75. Vessels with low-velocity blood flow can be imaged using three-dimensional power Doppler sonography. Induced non-vascular flow was detected in endometriotic cyst fluid. Three-dimensional power Doppler sonography combined with the cube method gave reproducible information for all indices except VFI 2. These indices might prove to be a new predictor in all fields of

  17. 99m-Tc DMSA scintigraphy and color/power doppler sonography for children pyelonephritis diagnosis and follow-up

    International Nuclear Information System (INIS)

    Hitzel, A.; Manrique, A.; Gardin, I.; Vera, P.; Hitzel, A.; Dacher, J.N.; Manrique, A.; Menard, J.F.; Gardin, I.; Vera, P.; Dacher, J.N.; Liard, A.; Menard, J.F.

    2004-01-01

    Early diagnosis of acute pyelonephritis is essential to avoid scarring development. This study was performed to evaluate capabilities of color/doppler sonography to detect pyelonephritis and to predict scarring when compared with 99m Tc-DMSA scintigraphy. Fifty-seven children were evaluated during pyelonephritis: biology (CRP, creatinine, blood formula), color/power doppler sonography and 99m Tc-DMSA scintigraphy (DMSA1). 7 ± 2 months later, follow-up consisted in biological tests and a 99m 'Tc-DMSA scintigraphy (DMSA2). During pyelonephritis, body temperature, CRP value and neutrophil counts were significantly higher in patients with an abnormal DMSA1 but not in patients with abnormal doppler sonography. When compared with DMSA1, doppler sonography sensitivity and specificity were 80% and 81% respectively. DMSA1 and doppler sonography were concordant in 86% of children with a pyelonephritis. At follow-up, all clinical et biological parameters were normalized. DMSA2 was abnormal in 51% of children. When compared with DMSA2, positive and negative predictive values for scarring of doppler sonography were 57% and 75% respectively. DMSA 1, positive and negative predictive values for scarring were 62% and 100%. In conclusion, color/power doppler sonography is a reliable tool for pyelonephritis diagnosis, but its predictive value for scarring is poor. Negative predictive value of DMSA scintigraphy is excellent. (author)

  18. Diagnostic imaging strategy for MDCT- or MRI-detected breast lesions: use of targeted sonography

    International Nuclear Information System (INIS)

    Nakano, Satoko; Ohtsuka, Masahiko; Mibu, Akemi; Karikomi, Masato; Sakata, Hitomi; Yamamoto, Masahiro

    2012-01-01

    Leading-edge technology such as magnetic resonance imaging (MRI) or computed tomography (CT) often reveals mammographically and ultrasonographically occult lesions. MRI is a well-documented, effective tool to evaluate these lesions; however, the detection rate of targeted sonography varies for MRI detected lesions, and its significance is not well established in diagnostic strategy of MRI detected lesions. We assessed the utility of targeted sonography for multidetector-row CT (MDCT)- or MRI-detected lesions in practice. We retrospectively reviewed 695 patients with newly diagnosed breast cancer who were candidates for breast conserving surgery and underwent MDCT or MRI in our hospital between January 2004 and March 2011. Targeted sonography was performed in all MDCT- or MRI-detected lesions followed by imaging-guided biopsy. Patient background, histopathology features and the sizes of the lesions were compared among benign, malignant and follow-up groups. Of the 695 patients, 61 lesions in 56 patients were detected by MDCT or MRI. The MDCT- or MRI-detected lesions were identified by targeted sonography in 58 out of 61 lesions (95.1%). Patients with pathological diagnoses were significantly older and more likely to be postmenopausal than the follow-up patients. Pathological diagnosis proved to be benign in 20 cases and malignant in 25. The remaining 16 lesions have been followed up. Lesion size and shape were not significantly different among the benign, malignant and follow-up groups. Approximately 95% of MDCT- or MRI-detected lesions were identified by targeted sonography, and nearly half of these lesions were pathologically proven malignancies in this study. Targeted sonography is a useful modality for MDCT- or MRI-detected breast lesions

  19. The role of colour Doppler sonography in the diagnosis of lower limb Klippel–Trénaunay syndrome

    International Nuclear Information System (INIS)

    Qi, H.T.; Wang, X.M.; Zhang, X.D.; Zhang, M.H.; Li, C.M.; Bao, S.G.; Yuan, H.

    2013-01-01

    Aim: To investigate the accuracy of colour Doppler sonography as compared to phlebography in patients with Klippel-Trénaunay syndrome (KTS). Materials and methods: From September 2004 to May 2012, 59 consecutive patients seen in Shandong medical imaging research institute with a clinical suggestion of KTS were included. Thirty-four were female and 25 were male, with a mean age of 28.4 years. Colour Doppler sonography was used to assess the lower limb veins. The main sonographic criteria for a positive diagnosis were visualization of the lateral vein or sciatic vein, capillary haemangioma, and abnormality of the deep veins. These data were compared with phlebography findings. The κ statistic was used to determine the level of agreement. The sensitivity, specificity, positive and negative predictive values, and accuracy of colour Doppler sonography as a diagnostic test were assessed. Results: Colour Doppler sonography findings were positive in 21 of 59 patients with a clinical suggestion of KTS. The diagnosis was confirmed using phlebography in 22 patients. There were two false-positive results and one false-negative result by colour Doppler sonography. The κ-value was 0.892. Sensitivity, specificity, positive and negative predictive values, and accuracy for colour Doppler sonography were 95.4, 94.6, 91.3, 97.2, and 94.9%, respectively. Conclusion: Colour Doppler sonography is an accurate, reliable, and non-invasive investigation in the assessment of patients with suspected KTS

  20. Impact of sonography in gouty arthritis: Comparison with conventional radiography, clinical examination, and laboratory findings

    International Nuclear Information System (INIS)

    Schueller-Weidekamm, Claudia; Schueller, Gerd; Aringer, Martin; Weber, Michael; Kainberger, Franz

    2007-01-01

    Objective: To explore the typical sonographic features of gray-scale and Power Doppler of acute and chronic gouty arthritis in conjunction with radiographic, clinical, and laboratory findings. Materials and methods: All hand, finger, and toe joints of 19 patients with acute and chronic gout were examined with gray-scale and Power Doppler sonography. The number and size of bone changes detected with sonography was compared to radiographic findings. Vascularization of the synovial tissue was scored on Power Doppler (grades 0-3), and was compared with clinical appearance, including swelling, tenderness, and redness (grades 0-3). Results: In acute gout, mild to moderate echogenic periarticular nodules with sonotransmission and hypervascularization of the edematous surrounding soft tissue were found. In chronic gout, tophaceous nodules completely blocked transmission of US wave, leading to strong reflexion and dorsal shadowing in a minority of cases. No significant difference in the detection of large bone changes (>2 mm) was found between sonography and radiography. However, gray-scale sonography was significantly more sensitive in the detection of small bone changes (p < 0.001). Power Doppler scores were statistically significantly higher than clinical examination scores (p < 0.001). Discussion: Sonography is superior to radiographs in evaluating small bone changes. The inflammatory process in joints can be better detected with Power Doppler sonography than with clinical examination. Typical sonographic appearance of acute and in particular of chronic gout might provide clues on gouty arthritis that adds to the information available from conventional radiography, clinical, and laboratory findings

  1. Impact of sonography in gouty arthritis: Comparison with conventional radiography, clinical examination, and laboratory findings

    Energy Technology Data Exchange (ETDEWEB)

    Schueller-Weidekamm, Claudia [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)]. E-mail: claudia.schueller-weidekamm@meduniwien.ac.at; Schueller, Gerd [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Aringer, Martin [Department of Rheumatology, Internal Medicine III, Medical University of Vienna (Austria); Weber, Michael [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Kainberger, Franz [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2007-06-15

    Objective: To explore the typical sonographic features of gray-scale and Power Doppler of acute and chronic gouty arthritis in conjunction with radiographic, clinical, and laboratory findings. Materials and methods: All hand, finger, and toe joints of 19 patients with acute and chronic gout were examined with gray-scale and Power Doppler sonography. The number and size of bone changes detected with sonography was compared to radiographic findings. Vascularization of the synovial tissue was scored on Power Doppler (grades 0-3), and was compared with clinical appearance, including swelling, tenderness, and redness (grades 0-3). Results: In acute gout, mild to moderate echogenic periarticular nodules with sonotransmission and hypervascularization of the edematous surrounding soft tissue were found. In chronic gout, tophaceous nodules completely blocked transmission of US wave, leading to strong reflexion and dorsal shadowing in a minority of cases. No significant difference in the detection of large bone changes (>2 mm) was found between sonography and radiography. However, gray-scale sonography was significantly more sensitive in the detection of small bone changes (p < 0.001). Power Doppler scores were statistically significantly higher than clinical examination scores (p < 0.001). Discussion: Sonography is superior to radiographs in evaluating small bone changes. The inflammatory process in joints can be better detected with Power Doppler sonography than with clinical examination. Typical sonographic appearance of acute and in particular of chronic gout might provide clues on gouty arthritis that adds to the information available from conventional radiography, clinical, and laboratory findings.

  2. Chest sonography. 2. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Mathis, Gebhard (ed.)

    2008-07-01

    Chest sonography is an established procedure in the stepwise imaging diagnosis of pulmonary and pleural disease. It is the method of choice to distinguish between solid and liquid lesions and allows the investigator to make an unequivocal diagnosis without exposing the patient to costly and stressful procedures. This book presents the state of the art in chest investigation by means of ultrasonography. A number of excellent illustrations and the compact text provide concise and easy-to-assimilate information about the diagnostic procedure. Basic elements such as indications, investigation techniques and image artifacts are detailed in separate chapters. (orig.)

  3. Chest sonography. 2. ed.

    International Nuclear Information System (INIS)

    Mathis, Gebhard

    2008-01-01

    Chest sonography is an established procedure in the stepwise imaging diagnosis of pulmonary and pleural disease. It is the method of choice to distinguish between solid and liquid lesions and allows the investigator to make an unequivocal diagnosis without exposing the patient to costly and stressful procedures. This book presents the state of the art in chest investigation by means of ultrasonography. A number of excellent illustrations and the compact text provide concise and easy-to-assimilate information about the diagnostic procedure. Basic elements such as indications, investigation techniques and image artifacts are detailed in separate chapters. (orig.)

  4. High-resolution X-ray television and high-resolution video recorders

    International Nuclear Information System (INIS)

    Haendle, J.; Horbaschek, H.; Alexandrescu, M.

    1977-01-01

    The improved transmission properties of the high-resolution X-ray television chain described here make it possible to transmit more information per television image. The resolution in the fluoroscopic image, which is visually determined, depends on the dose rate and the inertia of the television pick-up tube. This connection is discussed. In the last few years, video recorders have been increasingly used in X-ray diagnostics. The video recorder is a further quality-limiting element in X-ray television. The development of function patterns of high-resolution magnetic video recorders shows that this quality drop may be largely overcome. The influence of electrical band width and number of lines on the resolution in the X-ray television image stored is explained in more detail. (orig.) [de

  5. Muscle lesion comparing of imaging procedures (sonography and MRT) -experimental and clinical study

    International Nuclear Information System (INIS)

    Mellerowicz, H.; Lubasch, A.; Dulce, M.; Wagner, S.; Paul, B.

    1993-01-01

    Muscle injuries in sports are more common now. Diagnosis and follow up of muscle injuries is nowadays achieved by sonography and MRT. In order to assess the two imagine procedures, a direct test for comparison of sonography and MRT was performed in an experimental study: A standardised disconnection of m. triceps surae in rats was either sutured and glued or not treated. Clinical studies were performed in 26 patients suffering from muscle trauma. Sonography was proved to be a reliable procedure especially in follow up control until full weight bearing and should be used first. Negative or doubtfull findings require further investigation by MRT. Especially contrast medium (Gd-DTPA) assisted examinations enables a long term follow up and may even show small (muscle strain) and deep lying injuries. (orig.) [de

  6. Correlation between sonography and antibody activity in patients with Hashimoto thyroiditis.

    Science.gov (United States)

    Willms, Arnulf; Bieler, Dan; Wieler, Helmut; Willms, Diana; Kaiser, Klaus P; Schwab, Robert

    2013-11-01

    Patients with Hashimoto thyroiditis show structural changes of the thyroid that can be identified by a variety of sonographic criteria. We conducted this study to investigate whether there is a correlation between sonography and antibody activity and to assess the role of sonography in the diagnosis and follow-up of Hashimoto thyroiditis. In addition, we present a new classification system (termed the VESINC system [volume, echogenicity, sonographic texture, pseudonodular hypoechoic infiltration, nodules, and cysts]), which helps improve the clarity of sonographic findings. The study included 223 consecutive patients with previously diagnosed Hashimoto autoimmune thyroiditis who attended the thyroid clinic of the German Armed Forces Central Hospital in Koblenz for follow-up examinations between 2006 and 2008. Laboratory tests were performed to measure the levels of free triiodothyronine, free thyroxine, thyrotropin, anti-thyroglobulin antibodies (TgAbs), and antithyroid peroxidase antibodies (TPOAbs). Sonography was performed according to a strict protocol. We then assessed whether a correlation existed between antibody activity and the 6 sonographic variables of the VESINC system. Hypoechogenicity, heterogeneity, and pseudonodular hypoechoic infiltration were associated with significantly higher TPOAb activity (P Hashimoto thyroiditis.

  7. Interobserver variability of sonography for prediction of placenta accreta.

    Science.gov (United States)

    Bowman, Zachary S; Eller, Alexandra G; Kennedy, Anne M; Richards, Douglas S; Winter, Thomas C; Woodward, Paula J; Silver, Robert M

    2014-12-01

    The sensitivity of sonography to predict accreta has been reported as higher than 90%. However, most studies are from single expert investigators. Our objective was to analyze interobserver variability of sonography for prediction of placenta accreta. Patients with previa with and without accreta were ascertained, and images with placental views were collected, deidentified, and placed in random sequence. Three radiologists and 3 maternal-fetal medicine specialists interpreted each study for the presence of accreta and specific findings reported to be associated with its diagnosis. Investigator-specific sensitivity, specificity, and accuracy were calculated. κ statistics were used to assess variability between individuals and types of investigators. A total of 229 sonographic studies from 55 patients with accreta and 56 control patients were examined. Accuracy ranged from 55.9% to 76.4%. Of imaging studies yielding diagnoses, sensitivity ranged from 53.4% to 74.4%, and specificity ranged from 70.8% to 94.8%. Overall interobserver agreement was moderate (mean κ ± SD = 0.47 ± 0.12). κ values between pairs of investigators ranged from 0.32 (fair agreement) to 0.73 (substantial agreement). Average individual agreement ranged from fair (κ = 0.35) to moderate (κ = 0.53). Blinded from clinical data, sonography has significant interobserver variability for the diagnosis of placenta accreta. © 2013 by the American Institute of Ultrasound in Medicine.

  8. MRI, CT, and sonography in the preoperative evaluation of primary tumor extension in malignant pleural mesothelioma; MRT, CT und Sonographie in der praeoperativen Beurteilung der Primaertumorausdehnung beim malignen Pleuramesotheliom

    Energy Technology Data Exchange (ETDEWEB)

    Layer, G.; Steudel, A.; Schild, H.H. [Radiologische Universitaetsklinik Bonn (Germany); Schmitteckert, H.; Tuengerthal, S.; Schirren, J. [Thoraxklinik Heidelberg-Rohrbach (Germany); Kaick, G. van [Deutsches Krebsforschungszentrum Heidelberg (Germany). Schwerpunkt fuer Onkologische Diagnostik und Therapie

    1999-04-01

    Purpose: Evaluation of the diagnostic value of the imaging modalities computed tomography (CT), magnetic resonance imaging (MRI), and thoracic sonography in the preoperative staging of malignant pleural mesothelioma. Results: The accuracy rates for CT were 85%, 98%, 83%, 73%, 71%, and 83%. MRI had an accuracy of 71%, 92%, 71%, 83%, 71%, and 96%, the thoracic ultrasound examinations of 76%, 63%, 51%, 60%, 71% and 89%. Conclusions: According to these results CT remains the method of choice in the preoperative assessment of T-stage of malignant pleural mesothelioma. MRI is of nearly the same value, but is not a must. Sonography may be supplementary method for operation planning. (orig./AJ) [Deutsch] Ziel: Evaluation der diagnostischen Wertigkeit der Schnittbildverfahren MRT, CT und Sonographie in der praeoperativen Diagnostik des Pleuramesothelioms. Ergebisse: Die Treffsicherheiten betrugen fuer die genannten anatomischen Regionen im CT 85%, 98%, 83%, 73%, 71%, und 83%, im MRT 71%, 92%, 71%, 83%, 71% bzw. 96%, waehrend sich fuer die thorakale Ultraschalluntersuchung Treffsicherheiten von 76%, 63%, 51%, 60%, 71% und 89% errechneten. Schlussfolgerungen: Die CT bleibt damit das Verfahren erster Wahl in der praeoperativen Diagnostik des malignen Pleuramesothelioms. Eine unbedingte Forderung nach praeoperativer Durchfuehrung einer MRT-Untersuchung ergibt sich nach der vorliegenden Studie nicht. Die Sonographie des Thorax und oberen Abdomens liefert einen wichtigen ergaenzenden Beitrag bei der Planung der Operation des malignen Pleuramesothelioms. (orig./AJ)

  9. Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: experience with 59 implants.

    Science.gov (United States)

    Ahn, C Y; DeBruhl, N D; Gorczyca, D P; Shaw, W W; Bassett, L W

    1994-10-01

    With the current controversy regarding the safety of silicone implants, the detection and evaluation of implant rupture are causing concern for both plastic surgeons and patients. Our study obtained comparative value analysis of mammography, sonography, and magnetic resonance imaging (MRI) in the detection of silicone implant rupture. Twenty-nine symptomatic patients (total of 59 silicone implants) were entered into the study. Intraoperative findings revealed 21 ruptured implants (36 percent). During physical examination, a positive "squeeze test" was highly suggestive of implant rupture. Mammograms were obtained of 51 implants (sensitivity 11 percent, specificity 89 percent). Sonography was performed on 57 implants (sensitivity 70 percent, specificity 92 percent). MRI was performed on 55 implants (sensitivity 81 percent, specificity 92 percent). Sonographically, implant rupture is demonstrated by the "stepladder sign." Double-lumen implants may appear as false-positive results for rupture on sonography. On MRI, the "linguine sign" represents disrupted fragments of a ruptured implant. The most reliable imaging modality for implant rupture detection is MRI, followed by sonogram. Mammogram is the least reliable. Our study supports the clinical indication and diagnostic value of sonogram and MRI in the evaluation of symptomatic breast implant patients.

  10. Color doppler sonography in thickened gallbladder wall

    International Nuclear Information System (INIS)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki

    1996-01-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes

  11. Reframing conceptual physics: Improving relevance to elementary education and sonography majors

    Science.gov (United States)

    LaFazia, David Gregory

    This study outlines the steps taken to reframe the Waves and Periodicity unit within a conceptual physics course. Beyond this unit reframing process, this paper explores the activities that made up the reframed unit and how each was developed and revised. The unit was reframed to improve relevance of the activities to the Elementary Education and Diagnostic Medical Sonography majors who make up the bulk of the course roster. The unit was reframed around ten design principles that were built on best practices from the literature, survey responses, and focused interviews. These principles support the selection of a biology-integrated themed approach to teaching physics. This is done through active and highly kinesthetic learning across three realms of human experience: physical, social, and cognitive. The unit materials were designed around making connections to students' future careers while requiring students to take progressively more responsibility in activities and assessments. Several support strategies are employed across these activities and assessments, including an energy-first, guided-inquiry approach to concept scaffolding and accommodations for diverse learners. Survey responses were solicited from physics instructors experienced with this population, Elementary Education and Sonography program advisors, and curriculum design, learning strategies, and educational technology experts. The reframed unit was reviewed by doctoral-level science education experts and revised to further improve the depth and transparency with which the design principles reframe the unit activities. The reframed unit contains a full unit plan, lesson plans, and full unit materials. These include classroom and online activities, assessments, and templates for future unit and lesson planning. Additional supplemental materials are provided to support Elementary Education and Sonography students and program advisors and also further promote the reframed unit materials and design

  12. Follow-up Sonography after Sonoguided Renal Biopsy

    International Nuclear Information System (INIS)

    Kim, Hyung Soo; Park, Cheol Min; Cha, In Ho

    1996-01-01

    To assess ultrasonographic findings and clinical significance after renal biopsy. 174 cases of post-biopsy sonography were studied retrospectively. We classified post-biopsy hematoma on the basis of their size as small (thickness less than 1 cm, length less than 3cm), medium (thickness less than 1cm, length greater than 3 cm), large (thickness greater than 1 cm, length greater than 3 cm). We also compared bleeding parameters (prothrombin time, partial thromboplastin time) and renal function in both cases which had hematoma or not. Total 33 hematomas were found (19%). Small hematoma was observed in 14 cases, medium hematoma in 16 cases, large hematoma in 3 cases. Severe complications requiring prompt therapy occurred in 1 case(0.6%). In 6 cases hematocrit fell by more than 4%, all of these hematomas were observed on US. Severe complications after sonoguided renal biopsy were rare. There was poor correlation between prebiopsybleeding parameter, renal function and post-biopsy hematomas. And sonography is considered as adequate method for follow up of post-biopsy hematoma

  13. Suspected leaking abdominal aortic aneurysm: use of sonography in the emergency room.

    Science.gov (United States)

    Shuman, W P; Hastrup, W; Kohler, T R; Nyberg, D A; Wang, K Y; Vincent, L M; Mack, L A

    1988-07-01

    To determine the value of sonography in the emergent evaluation of suspected leaking abdominal aortic aneurysms, the authors examined 60 patients in the emergency department using sonography and a protocol involving advance radio notification from the ambulance; arrival of sonographic personnel and equipment in the triage room before patient arrival; and, during other triage activities, rapid sonographic evaluation of the aorta for aneurysm and of the paraaortic region for extraluminal blood. Sonographic findings were correlated with surgical results and clinical outcome. When performed under these circumstances, sonography was accurate in demonstrating presence or absence of aneurysm (98%), but its sensitivity for extraluminal blood was poor (4%). A combination of sonographic confirmation of aneurysm, abdominal pain, and unstable hemodynamic condition resulted in the correct decision to perform emergent surgery in 21 of 22 patients (95%). An abbreviated sonographic examination done in the emergency room can provide accurate, useful information about the presence of aneurysm; this procedure does not significantly delay triage of these patients.

  14. Addison's disease with adrenal enlargement on sonography and computed toimography

    International Nuclear Information System (INIS)

    Renner, F.; Graninger, W.

    1986-01-01

    One of the major causes of chronic adrenal insufficiency (Addison's disease) is tuberculous adrenalopathy. Since sonography and computed tomography have become generally available in recent years and are of potential help in the diagnosis of this disease the merits of these methods are discussed in the light of 2 cases of adrenal tuberculosis, followed by a review of the literature. Adrenal calcification is the most significant, although not specific sign of adrenal insufficiency due to tuberculosis. Computed tomography has proven to be the method of choice in the non-invasive diagnosis of tuberculous adrenalopathy and in the monitoring of tuberculostatic treatment in this disease. Sonography is helpful as a preliminary investigation. (Author)

  15. Value of breast MRI as supplement to mammography and sonography for high risk breast cancer patients; Wertigkeit der Mamma-MRT als Ergaenzung zu Mammographie und Sonographie bei Patientinnen mit erhoehtem Mammakarzinomrisiko

    Energy Technology Data Exchange (ETDEWEB)

    Schlossbauer, T.; Hellerhoff, K.; Reiser, M. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2008-04-15

    The aim of this study is to give an overview on early detection of breast cancer in patients with an increased risk of breast cancer. Sensitivities and diagnostic accuracies of breast MRI, mammography and ultrasound were compared. A systematic literature search of the past 3 years was performed. Studies which compared breast imaging modalities and used image-guided biopsy results as standard of reference were included. Patients included had to have had an increased lifetime risk for breast cancer (>15%). Regarding sensitivity and diagnostic accuracy, breast MRI performed best in comparison to the other modalities within this collective of patients. Sensitivities ranged from 71-100%, 0-78%, and 13-65%, for MRI, mammography, and ultrasound, respectively Breast MRI is a well established tool for screening in patients at high risk for developing breast cancer and is a valuable supplement to mammography and ultrasound within this selected cohort of patients. (orig.) [German] Ziele der Arbeit sind die inhaltliche Einfuehrung in das Thema Frueherkennung des Mammakarzinoms bei Patientinnen mit erhoehtem Risiko und eine systematische Analyse der Wertigkeit von MRT und anderen bildgebenden Verfahren in diesem Zusammenhang. Es wurde eine systematische Literaturrecherche ueber die letzten 3 Jahre durchgefuehrt. Dabei wurden Vergleichsstudien der verschiedenen bildgebenden Verfahren in der Mammadiagnostik beruecksichtigt, bei denen die bildgesteuerte Biopsie als Goldstandard angegeben wurde. Von allen bildgebenden Verfahren zeigt die Mamma-MRT bei Patientinnen mit familiaerem Risiko die hoechste Sensitivitaet und diagnostische Genauigkeit bei der Detektion des Mammakarzinoms. Fuer MRT, Mammographie und Sonographie werden Sensitivitaeten zwischen 71 und 100%, 0 und 78% sowie 13 und 65% angegeben. Die Mamma-MRT ist ein etabliertes Verfahren zum Screening von Risikopatientinnen. Uebereinstimmend wird der diagnostische Nutzen der Mamma-MRT als ergaenzendes Verfahren zu Mammographie

  16. Unenhanced helical CT in the evaluation of the urinary tract in children and young adults following urinary tract reconstruction: comparison with sonography

    Energy Technology Data Exchange (ETDEWEB)

    Myers, M.T.; Elder, J.S.; Sivit, C.J.; Applegate, K.E. [Dept. of Radiology, Rainbow Babies and Children' s Hospital, Cleveland, OH (United States)

    2001-03-01

    Purpose. To compare the accuracy of unenhanced, helical CT with sonography for the detection of complications of urinary tract reconstruction. Materials and methods. Forty-six kidneys in 24 patients were examined with CT and sonography. All scans were assessed for ease of renal visualization, presence of renal, ureteral, and bladder calculi, renal scars, hydronephrosis, and abdominal wall hernia. The results of both imaging modalities were independently reported. Results. CT provided excellent visualization of all 46 kidneys, while sonography provided poor visualization of 8 kidneys (17 %) (P < 0.001). CT detected calculi in 10 kidneys, 1 ureter, and 7 bladders. Sonography detected calculi in only 2 kidneys, and 2 bladders. Overall, CT detected significantly more calculi than US (18 vs 4, P = 0.01). CT detected scarring in 15 kidneys, while sonography detected scarring in 10. Hydronephrosis was detected in 6 kidneys by CT and in 8 kidneys by sonography. Three abdominal wall hernias were seen at CT that were not seen at sonography. Conclusion. CT is superior to sonography for the detection of urinary tract calculi and renal scarring. CT will demonstrate abdominal wall hernias that are unsuspected. (orig.)

  17. Use of chest sonography in acute-care radiology☆

    Science.gov (United States)

    De Luca, C.; Valentino, M.; Rimondi, M.R.; Branchini, M.; Baleni, M. Casadio; Barozzi, L.

    2008-01-01

    Diagnosis of acute lung disease is a daily challenge for radiologists working in acute-care areas. It is generally based on the results of chest radiography performed under technically unfavorable conditions. Computed tomography (CT) is undoubtedly more accurate in these cases, but it cannot always be performed on critically ill patients who need continuous care. The use of thoracic ultrasonography (US) has recently been proposed for the study of acute lung disease. It can be carried out rapidly at the bedside and does not require any particularly sophisticated equipment. This report analyzes our experience with chest sonography as a supplement to chest radiography in an Emergency Radiology Unit. We performed chest sonography – as an adjunct to chest radiography – on 168 patients with acute chest pathology. Static and dynamic US signs were analyzed in light of radiographic findings and, when possible, CT. The use of chest US improved the authors' ability to provide confident diagnoses of acute disease of the chest and lungs. PMID:23397048

  18. Esophageal and anorectal involvement in systemic sclerosis: a systematic assessment with high resolution manometry.

    Science.gov (United States)

    Luciano, Laure; Granel, Brigitte; Bernit, Emmanuelle; Harle, Jean-Robert; Baumstarck, Karine; Grimaud, Jean-Charles; Bouvier, Michel; Vitton, Véronique

    2016-01-01

    In systemic sclerosis (SSc), esophageal and anorectal involvements are frequent and often associated with each other. In clinical practice, esophageal explorations are often prescribed, while anorectal explorations are rarely proposed and therefore, under-recognised. However, it is well documented in the literature that early detection of anorectal dysfunction could delay and/or prevent the onset of symptoms such as fecal incontinence (FI). The main objective was the systematic evaluation and detection of esophageal and anorectal involvements in SSc patients. In this monocentric retrospective study, all patients with SSc addressed in the Department of Functional Digestive Explorations, North Hospital, Marseille for esophageal and anorectal explorations were included. Self-Questionnaires, evaluating the symptoms and quality of life, were filled by patients during their visit. Explorations were performed on the same day: high resolution esophageal manometry (EHRM), 3 Dimensional high resolution anorectal manometry (3DHRARM) and endo anal sonography (EUS). 44 patients (41 women), mean age 59.8±12 years, were included. With regard to the symptoms, 45.5% of patients had gastro-esophageal reflux disease (GERD), 66.9% dysphagia, 65.9% constipation and 77.3% FI. The incidence of esophageal dismotility was 65.9%, anorectal and both upper and lower dysfunction were 43.2%. More than 89% patients with abnormal explorations (EHRM, 3DHRARM or both) were symptomatic. Duration of SSc and altered quality of life was correlated with the severity of digestive involvement. Anorectal dysfunction appears to be closely linked to esophageal involvement in SSc. Their routine screening is undoubtedly essential to limit the occurrence of severe symptoms such as FI.

  19. Duplex sonography in portal hypertension

    International Nuclear Information System (INIS)

    Kwon, Hyuk Po; Jang, J. C.; Park, B. H.

    1990-01-01

    We measure the diameter and blood velocity of the portal vein in 50 patients with cirrhosis of the liver and 40 healthy subjects, and calculated cross sectional area, mean blood flow velocity, blood flow volume and congestion index. In patients with cirrhosis of the liver, the cross sectional area of the portal vein was significantly increased: the mean blood flow volume was significantly reduced; the blood flow volume was significantly increased; the congestion index of the portal vein was significantly increased. Duples sonography may play an important role in the diagnosis of portal hypertension

  20. The Significance of Brain Transcranial Sonography in Burning Mouth Syndrome: a Pilot Study.

    Science.gov (United States)

    Zavoreo, Iris; Vučićević, Vanja; Boras; Zadravec, Dijana; Bašić, Vanja; Kes; Ciliga, Dubravka; Gabrić, Dragana

    2017-03-01

    Burning mouth syndrome (BMS) is a chronic disorder which is affecting mostly postmenopausal women and is characterized by burning symptoms in the oral cavity on the clinically healthy oral mucosa. Also, the results of previous studies suggested a possible role of peripheral and/or central neurological disturbances in these patients. The aim of this study was to analyze patients with burning mouth syndrome using transcranial sonography. By use of transcranial sonography of the brain parenchyma, substantia nigra , midbrain raphe and brain nucleus were evaluated in 20 patients with BMS (64.7±12.3 years) and 20 controls with chronic pain in the lumbosacral region (61.5±15). Statistical analysis was performed by use of Student t test with significance set at pburning mouth syndrome might reflect central disturbances within this syndrome. Burning Mouth Syndrome; Transcranial Sonography; substantia nigra; Midbrain Raphe Nuclei; Red Nucleus.

  1. Comparison of sonography and venography in the diagnosis of lower extremity deep venous thrombosis

    International Nuclear Information System (INIS)

    Mostbeck, G.H.; Kettenbach, J.; Henk, C.

    1993-01-01

    In recent years, non-invasive sonographic techniques [real-time ultrasound (US), duplex ultrasonography (DU) and color-coded duplex sonography (CCDS)] have increased in importance for the diagnosis of lower extremity deep venous thrombosis. To ascertain the accuracy and limitations of these techniques prospectively, various studies have been performed to compare sonography with venography. This review deals with basic methodologic considerations when two imaging methds are compared and describes the features of deep venous thrombosis seen on US, DU and CCDS. Reports comparing sonography and phlebography for the diagnosis of deep venous thrombosis are presented and discussed. The advantages and limitations of US, DU and CCDS for the diagnosis of iliac, femoral, popliteal and infrapopliteal venous thrombosis are compared with those of venography, and controversial areas are touched on. (orig.) [de

  2. Usefulness of high-resolution sonography for assessement of hepatocellular carcinoma in the transgenic mice expressing hepatitis B virus X-protein; A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Kwon-Ha; Park, Sung Hoon; Kim, Chang Guhn; Won, Jong Jin; Moon, Hyung Bae [Wonkwang Univ. School of Medicine, Iksan (Korea, Republic of); Yu, Dae Yeul [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    2000-11-01

    To determine the value of high resolution ultrasonography (US) for the detection of hepatocellular carcinoma in the HBx transgenic mice. Forty-two HBx transgenic mice aged 8-20 (mean, 14) months underwent high-resolution ultrasound using a 10-12 MHz linear transducer. US findings indication the presence or absence, number, size and echogenicity of each hepatic tumor were analyzed, and in addition, color or power Doppler US was used to analyse tumoral vascularity. In each animal, sacrificed less than five hours after US examination, sonographic and pathologic findings were correlated. On gross pathologic examination, 20 hepatocellular carcinomas measuring 1.5-15 (mean, 4.7) mm in diameter were found in 16 mice; US revealed that 17 of the tumors were homogeneous hypoechoic nodules. With regard to tumor detection, sensitivity was 85%, specificity 96%, positive predictive value 0.944, negative predictive value 0.897, and overall accuracy 90%. Doppler US revealed that in three nodules, intratumoral vessels were present. In the other 26 mice, gross examination showed that no mass was present; microscopically, however, four nodules measuring 0.3-1.2 mm were found in four of these animals. Tumoral vascularity detected by color Doppler US corresponded to the intratumoral vessel within the nodules. One peritoneal nodule, confirmed as a metastatic tumor, was found at the greater omentum. In HBx transgenic mice, high-resolution US is valuable for the detection of hepatocellular carcinoma.

  3. The forgotten organ: Contrast enhanced sonography of the spleen

    International Nuclear Information System (INIS)

    Goerg, Christian

    2007-01-01

    Objective: Ultrasound contrast agents in conjunction with contrast specific imaging techniques, are increasingly accepted in clinical use for diagnostic imaging in several organs. Contrast enhanced sonography (CES) of second-generation contrast media have shown a spleen-specific uptake of the microbubble contrast agent. The aim of this review is to illustrate indications for the use of CES in patients with suspected (peri-)splenic pathology. Methods: This review based on the experience of transcutaneous CES in 200 patients with (peri-)splenic pathology diagnosed by B-mode sonography at an internal medicine center. CES studies were performed with a contrast-devoted unit (Acuson, Sequoia, Siemens medical solution) that had contrast-specific, continuous-mode software. A low mechanical index was used. A sulfur hexafluoride-based microbubble contrast medium (Sonovue, Bracco SpA, Milan, Italy) was injected. Results: On our experience, there are several clinical conditions which may show an diagnostic advantage of CES in comparison to B-mode US. CES should be performed to investigate: (1) the perisplenic tumor to diagnose or exclude accessory spleen, (2) the small-sized spleen to diagnose functional asplenia/hyposplenia, (3) the inhomogenous spleen of unknown cause to diagnose focal lesions within the spleen, (4) the incidentally found hypoechoic splenic tumor to diagnose high vascular splenic hemangioma, (5) focal lesions suspect for splenic abscess, hematoma, infarction to confirme diagnosis, and (6) patients with abdominal trauma to diagnose or exclude splenic injuriy. Conclusion: CES is of diagnostic value in several clinical circumstances to diagnose accessory spleen, functional asplenia, small-sized splenic involvement, high vascular splenic hemangioma, and vascular splenic pathology like splenic infarction, splenic abscess, and splenic laceration

  4. The forgotten organ: Contrast enhanced sonography of the spleen

    Energy Technology Data Exchange (ETDEWEB)

    Goerg, Christian [Medizinische Universitaetsklinik, Baldingerstrasse, 35043 Marburg/Lahn (Germany)], E-mail: goergc@med.uni-marburg.de

    2007-11-15

    Objective: Ultrasound contrast agents in conjunction with contrast specific imaging techniques, are increasingly accepted in clinical use for diagnostic imaging in several organs. Contrast enhanced sonography (CES) of second-generation contrast media have shown a spleen-specific uptake of the microbubble contrast agent. The aim of this review is to illustrate indications for the use of CES in patients with suspected (peri-)splenic pathology. Methods: This review based on the experience of transcutaneous CES in 200 patients with (peri-)splenic pathology diagnosed by B-mode sonography at an internal medicine center. CES studies were performed with a contrast-devoted unit (Acuson, Sequoia, Siemens medical solution) that had contrast-specific, continuous-mode software. A low mechanical index was used. A sulfur hexafluoride-based microbubble contrast medium (Sonovue, Bracco SpA, Milan, Italy) was injected. Results: On our experience, there are several clinical conditions which may show an diagnostic advantage of CES in comparison to B-mode US. CES should be performed to investigate: (1) the perisplenic tumor to diagnose or exclude accessory spleen, (2) the small-sized spleen to diagnose functional asplenia/hyposplenia, (3) the inhomogenous spleen of unknown cause to diagnose focal lesions within the spleen, (4) the incidentally found hypoechoic splenic tumor to diagnose high vascular splenic hemangioma, (5) focal lesions suspect for splenic abscess, hematoma, infarction to confirme diagnosis, and (6) patients with abdominal trauma to diagnose or exclude splenic injuriy. Conclusion: CES is of diagnostic value in several clinical circumstances to diagnose accessory spleen, functional asplenia, small-sized splenic involvement, high vascular splenic hemangioma, and vascular splenic pathology like splenic infarction, splenic abscess, and splenic laceration.

  5. ANL high resolution injector

    International Nuclear Information System (INIS)

    Minehara, E.; Kutschera, W.; Hartog, P.D.; Billquist, P.

    1985-01-01

    The ANL (Argonne National Laboratory) high-resolution injector has been installed to obtain higher mass resolution and higher preacceleration, and to utilize effectively the full mass range of ATLAS (Argonne Tandem Linac Accelerator System). Preliminary results of the first beam test are reported briefly. The design and performance, in particular a high-mass-resolution magnet with aberration compensation, are discussed. 7 refs., 5 figs., 2 tabs

  6. Usefulness of sonography in women less than 35 years old with palpable breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Ju; Chung, Hyun Ung; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun; Kim, Jae Kyu; Chung, Hyon De [Chonnam National University College of Medicine, Gwangju (Korea, Republic of)

    1994-12-15

    To assess the usefulness of sonography in the evaluation of palpable mass in patients less than 35 years old,the breast sonograms and mammograms of 105 histopathologically proved cases were retrospectively reviewed. Breast parenchymal patterns on mammogram, sensitivity of sonography and mammography in the diagnosis of palpable breast masses, and sonographic findings of breast masses were analyzed. Grade IV breast parenchymal pattern was demonstrated in 44 of 76 mammogram (57.9%). The incidence of Grade IV pattern increased, as the patients' age became younger. The sensitivity of sonography (81.3%) was higher than that of mammography (45.3%) in the evaluation of the benign breast lesions. However, the sensitivity of both modalities were nearly equal (66.7% and 58.3% respectively) in the evaluation of the breast cancers. Sonographic findings of fibroadenoma included oval,well defined border, smooth contour, weak homogeneous internal echoes, posterior sonic enhancement, and bilateral shadows. On the other hand, breast cancer exhibited poorly defined border, irregular contour, and inhomogeneous hypoechoic mass with posterior sonic attenuation. In summary, sonography was useful in the evaluation of the palpable breast mass in women less than 35 years old. Choreoathetotic sonographic findings might help the differential diagnosis of breast masses

  7. Usefulness of sonography in women less than 35 years old with palpable breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Ju; Chung, Hyun Ung; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun; Kim, Jae Kyu; Chung, Hyon De [Chonnam National University College of Medicine, Gwangju (Korea, Republic of)

    1994-12-15

    To assess the usefulness of sonography in the evaluation of palpable mass in patients less than 35 years old,the breast sonograms and mammograms of 105 histopathologically proved cases were retrospectively reviewed. Breast parenchymal patterns on mammogram, sensitivity of sonography and mammography in the diagnosis of palpable breast masses, and sonographic findings of breast masses were analyzed. Grade IV breast parenchymal pattern was demonstrated in 44 of 76 mammogram (57.9%). The incidence of Grade IV pattern increased, as the patients' age became younger. The sensitivity of sonography (81.3%) was higher than that of mammography (45.3%) in the evaluation of the benign breast lesions. However, the sensitivity of both modalities were nearly equal (66.7% and 58.3% respectively) in the evaluation of the breast cancers. Sonographic findings of fibroadenoma included oval,well defined border, smooth contour, weak homogeneous internal echoes, posterior sonic enhancement, and bilateral shadows. On the other hand, breast cancer exhibited poorly defined border, irregular contour, and inhomogeneous hypoechoic mass with posterior sonic attenuation. In summary, sonography was useful in the evaluation of the palpable breast mass in women less than 35 years old. Choreoathetotic sonographic findings might help the differential diagnosis of breast masses

  8. High resolution ultrasound and magnetic resonance imaging of the optic nerve and the optic nerve sheath: anatomic correlation and clinical importance.

    Science.gov (United States)

    Steinborn, M; Fiegler, J; Kraus, V; Denne, C; Hapfelmeier, A; Wurzinger, L; Hahn, H

    2011-12-01

    We performed a cadaver study to evaluate the accuracy of measurements of the optic nerve and the optic nerve sheath for high resolution US (HRUS) and magnetic resonance imaging (MRI). Five Thiel-fixated cadaver specimens of the optic nerve were examined with HRUS and MRI. Measurements of the optic nerve and the ONSD were performed before and after the filling of the optic nerve sheath with saline solution. Statistical analysis included the calculation of the agreement of measurements and the evaluation of the intraobserver and interobserver variation. Overall a good correlation of measurement values between HRUS and MRI can be found (mean difference: 0.02-0.97 mm). The repeatability coefficient (RC) and concordance correlation coefficient (CCC) values were good to excellent for most acquisitions (RC 0.2-1.11 mm; CCC 0.684-0.949). The highest variation of measurement values was found for transbulbar sonography (RC 0.58-1.83 mm; CCC 0.615/0.608). If decisive anatomic structures are clearly depicted and the measuring points are set correctly, there is a good correlation between HRUS and MRI measurements of the optic nerve and the ONSD even on transbulbar sonography. As most of the standard and cut-off values that have been published for ultrasound are significantly lower than the results obtained with MRI, a reevaluation of sonographic ONSD measurement with correlation to MRI is necessary. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Budd-chiari syndrome by membranous obstruction of inferior vena cava: comparison of sonography and computed tomography

    International Nuclear Information System (INIS)

    Lee, Dong Ho; Lim, Jae Hoon; Ko, Young Tae; Yoon, Yup; Lim, Joo Won

    1992-01-01

    Membranous obstruction of the hepatic inferior vena cava (MOVC) is one of the common causes of Budd-Chiari syndrome. The aim of this study is to ascertain and compare the characteristic sonographic and CT findings of Budd-Chiari syndrome caused by MOVC. We studied 10 patients of Budd-Chiari syndrome caused by MOVC thorough sonography and CT. MOVC was confirmed by operation and/or inferior vena cavography. The cases included 9 men and one woman. With sonography, IVC obstruction was diagnosed in 9 cases. The cause of IVC obstruction was web in 5 cases and fibrous cord in 3 cases. The cause was unspecified in one case. Obliteration of the hepatic veins and intrahepatic collateral vessels were delineated in 9 cases. With color doppler sonography, the directions of blood flow of the hepatic veins through the intervenous communication were fairly well demonstrated in all 5 cases. With CT, IVC obstruction was diagnosed in 7 cases. The obliteration of the hepatic segment of the IVC were segmental in 6 cases and diffuse in one case. CT demonstrated communicating vessels between the hepatic veins in 3 cases. Furthermore, systemic collateral vessels (azygos and hemiazygos veins, veins along the abdominal wall, and internal mammary veins) were demonstrated in all cases. Liver cirrhosis was combined in all cases and hepatoma developed in 4 cases. Sonography is useful to detect the MOVC and to demonstrate hepatic venous obstruction and intrahepatic collateral vessels. Color doppler sonography is easily performed to show the direction of the blood flow through interconnecting vessels. CT shows the obliterated segment of the IVC clearly and multiple prominent systemic collaterals. In conclusion, Budd-Chiari syndrome caused by MOVC is accurately diagnosed by combined color doppler sonography and CT

  10. Upper Abdominal Ultra-Sonography Findings in HIV Patients at ...

    African Journals Online (AJOL)

    Design: A descriptive cross-sectional study. Setting: Kenyatta National Hospital and the Defence Forces Memorial Hospital, Nairobi, Kenya. Subjects: HIV infected patients referred for upper abdominal sonography within the study duration of eight months. Results: Two hundred and seventy three (273) patients were ...

  11. Plantar fascia softening in plantar fasciitis with normal B-mode sonography.

    Science.gov (United States)

    Wu, Chueh-Hung; Chen, Wen-Shiang; Wang, Tyng-Guey

    2015-11-01

    To investigate plantar fascia elasticity in patients with typical clinical manifestations of plantar fasciitis but normal plantar fascia morphology on B-mode sonography. Twenty patients with plantar fasciitis (10 unilateral and 10 bilateral) and 30 healthy volunteers, all with normal plantar fascia morphology on B-mode sonography, were included in the study. Plantar fascia elasticity was evaluated by sonoelastographic examination. All sonoelastograms were quantitatively analyzed, and less red pixel intensity was representative of softer tissue. Pixel intensity was compared among unilateral plantar fasciitis patients, bilateral plantar fasciitis patients, and healthy volunteers by one-way ANOVA. A post hoc Scheffé's test was used to identify where the differences occurred. Compared to healthy participants (red pixel intensity: 146.9 ± 9.1), there was significantly less red pixel intensity in the asymptomatic sides of unilateral plantar fasciitis (140.4 ± 7.3, p = 0.01), symptomatic sides of unilateral plantar fasciitis (127.1 ± 7.4, p plantar fasciitis (129.4 ± 7.5, p plantar fascia thickness or green or blue pixel intensity among these groups. Sonoelastography revealed that the plantar fascia is softer in patients with typical clinical manifestations of plantar fasciitis, even if they exhibit no abnormalities on B-mode sonography.

  12. Transvaginal sonography in abnormal uterine bleeding and correlation to hysteroscopy

    International Nuclear Information System (INIS)

    Saeed, S.; Shah, S.; Ali, H.; Khan, S.; Ehsan, N.; Ahmed, S.Z.

    2017-01-01

    To correlate results of Transvaginal sonography with those of hysteroscopy and biopsy in abnormal uterine bleeding to estimate the accuracy and analytical values of non-invasive transvaginal sonography in abnormal uterine bleeding. Methodology: This cross-sectional Study was carried out at BMCH, Quetta, Balochistan, Pakistan from March 2013 to February 2014 and included 200 patients of abnormal uterine bleeding. Exclusion criteria were pregnancy, virginity, local bleeding of perineal or vaginal origin. Hysteroscopy and biopsy and Transvaginal Ultrasound (TVS) were performed in all. Result: The most common type of bleeding was found to be menorrhagia in 39% while the least common type was postmenopausal bleeding in 9%. Mean endometrial thickness was 11.64 mm and it was noted that at less than 14mm thickness no serious pathology was found. Sensitivity of TVS for endometrial hyperplasia was found to be 66.66% while specificity was 100%. Positive analytical value was 100% while negative value was 100%. Overall sensitivity calculated for TVS was 94.44%, specificity 98.55%, PPV was 81.93% and NPV 98.55%. Conclusion: Sensitivity and specificity of TVS were lower than hysteroscopy and biopsy but the difference was not significant. TVS can be used as first line investigation while hysteroscopy and biopsy may be left for cases of high risk or in those cases where some positive findings could be found on TVS. (author)

  13. The role of sonography in patients with breast cancer presenting as an axillary mass

    International Nuclear Information System (INIS)

    Park, Sun Young; Kim, Eun Kyung; Oh, Ki Keun; Lee, Kyong Sik; Park, Byeong Woo

    2002-01-01

    To compare sonography and mammography in terms of their diagnostic value in breast cancer cases which initially presented as an axillary mass without a palpable mass or other clinical symptoms. Seven patients with enlarged axillary lymph nodes who first presented with no evidence of palpable breast lesions and who underwent both mammography and sonography were enrolled in this study. In six of the seven, the presence of metastatic adenocarcinoma was confirmed preoperatively by axillary needle aspiration biopsy; in four, subsequent sonographically guided breast core biopsy performed after careful examination of the primary site indicated that primary breast cancer was present. In each case, the radiologic findings were evaluated by both breast sonography and mammography. Breast lesions were detected mammographically in four of seven cases (57%); in three of the four, the lesion presented as a mass, and in one as microcalcification. In three of these four detected cases, fatty or scattered fibroglandular breast parenchyma was present; in one, the parenchyma was dense. In the three cases in which lesions were not detected, mammography revealed the presence of heterogeneously dense parenchyma. Breast sonography showed that lesions were present in six of seven cases (86%); in the remaining patient, malignant microcalcification was detected at mammography. Final pathologic examination indicated that all breast lesions except one, which was a ductal carcinoma in situ, with microinvasion, were infiltrating ductal carcinomas whose size ranged from microscopic to greater than 3 cm. At the time of this study, all seven patients were alive and well, having been disease free for up to 61 months after surgery. In women with a palpable axillary mass confirmed as metastatic adenocarcinoma, breast sonography may be a valuable adjunct to mammography

  14. Comparison of findings of spontaneous splenorenal shunt in color Doppler sonography with multislice CT scan (64 slices) in liver transplant candidates

    Energy Technology Data Exchange (ETDEWEB)

    Bagheri, Mohammadhadi, E-mail: Bagherimh@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Hajati, Azadeh, E-mail: azadeh.hajati@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Hosseini, Mohammadkazem, E-mail: hosseiniaslm@sums.ac.ir [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Ostad, Seyed Pouria, E-mail: Pouria.Ostad@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of)

    2012-09-15

    Background: Liver transplantation is the only definite treatment for end stage liver disease and it has high costs for the medical system so decreasing its complication and increasing its effectiveness is crucial. One of the factors that affect liver transplantation is the presence of spontaneous splenorenal shunt. Its diagnosis is mainly overlooked in pre-liver transplant patients. Main modality for its diagnosis is multislice CT scan however this is more expensive than sonography. Also, it exposes the patients to ionizing radiation. Considering the advantages of color Doppler ultrasound, studies to determine the sensitivity and specificity for detection of spontaneous splenorenal shunt is essential. Materials and methods: In our study 70 cirrhotic patients who were referred by liver transplant surgeons for evaluation of abdomen by CT and sonograhy were assessed for presence of spontaneous splenorenal shunt, left adrenal varix and left renal vein diameter and velocity and sensitivity and specificity of both modalities were checked. Patients in whom left renal vein could not evaluated by sonography and patients with splenectomy and nutcracker syndrome were excluded. Results: In the point of 10 mm diameter of left renal vein in CT scan there was 78.6% sensitivity and 67.9% specificity for the presence of spontaneous splenorenal shunt. Left adrenal varix in CT had sensitivity of 71.4%, specificity of 100%, and positive predictive value of 100% and negative predictive value of 70% and varix below spleen in CT had sensitivity of 54.8%, specificity of 96.4%, and positive predictive value of 95.8% and negative predictive value of 58.7% for the presence of spontaneous splenorenal shunt. In the point of 8 mm diameter of left renal vein in sonography there was 66.7% sensitivity and 85.7% specificity for the presence of spontaneous splenorenal shunt. For the velocity of more than 35 cm/s of left renal vein in sonography there was 61.9% sensitivity and 82.1% specificity for

  15. Phylloedes tumor of breast: findings at mammography, sonography and color Doppler imaging

    International Nuclear Information System (INIS)

    Park, Kun Choon; Ahn, Sei Hyun; Kim, Young Hwan; Choi, Hye Yong; Baek, Seung Yon; Yoon, Jeong Hyun

    1994-01-01

    The phylloides tumor of the breast is rare. the purposes of this study were to find the characteristic findings at mammography, sonography, and color Doppler imaging and to evaluate the usefulness of color Doppler study as an additional modality in the diagnosis of phylloides tumor and differentiation between benign and malignant varieties. Eight cases, who were pathologically proven as pylloides tumors, were retrospectively studied. The findings at histologic examination suggested benign in five, malignantin two, and borderline in one. We analyzed the mammograms of all eight patients and sonogram and color Doppler images of four patients. Phylloides tumors were seen as dense masses with lobulated margins in mammograms. On sonography, they showed relatively well-defined masses with in homogenous internal echo pattern and central echogenic areas. They were characterized by the presence of arterial and venous flows in the center and periphery of the lesion on color Doppler imaging and spectral analysis. We conclude that mammographic, sonographic and even color Doppler findings are not predictive of benign or malignant nature of the phylloides tumor. However, mammography and sonography with color Doppler interrogation are helpful in the diagnosis of phylloides tumor

  16. Abnormal uterine bleeding due to vascular abnormality caused by D and E : doppler sonography for diagnosis and transcatheter arterial embolization for treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Jo; Heo, Chan; Jung, Tae Gun; Kim, Gi Sung; Kwon, Hyeok Po; Lee, Sang Kwon; Kwon, Jung Hyeok [Dongkang Hospital, Ulsan (Korea, Republic of); Lee, Yeong Hwan [Taegu Catholic Univ. School of Medicine, Taegu (Korea, Republic of)

    1996-06-01

    We attempted to evaluate the usefulness of Doppler sonography in the diagnosis of uterine vascular abnormality caused by previous D and E, and to report that transarterial embolization is an excellent treatment modality. We analyzed gray-scale US, color/duplex Doppler US and angiographic findings in seven patients with radiologically proven uterine vascular abnormality. Two of the seven cases were pseudoaneurysms and five of the seven cases were AVMs. n one of the AVMS, two small pseudoaneurysms were combined. In all cases, transarterial embolizations using 3 mm coil or/and gelfoam particles were performed. Follow-up US studies, including color Doppler US, were performed. on color/duplex Doppler sonography, two cases of pseudoaneurysm showed blood pools with turbulent arterial flow, and five cases of AVM showed asymmetrically increased cascularity, with vailable high velocities composed of the pulsatile arterial flow, with a high diastolic component. on angiography, the former showed pseudoaneruysmal sacs, and the latter densely opacified vascular tangles. No more abnormal uterine bleeding was shown following transarterial embolization in all cases. Color/duplex Doppler sonography was valuable in the diagnosis or treatment of abnormal uterine bleeding caused by uterine vascular abnormality such as acquired AVM or pseudoaneruysm.

  17. Abnormal uterine bleeding due to vascular abnormality caused by D and E : doppler sonography for diagnosis and transcatheter arterial embolization for treatment

    International Nuclear Information System (INIS)

    Kim, Yong Jo; Heo, Chan; Jung, Tae Gun; Kim, Gi Sung; Kwon, Hyeok Po; Lee, Sang Kwon; Kwon, Jung Hyeok; Lee, Yeong Hwan

    1996-01-01

    We attempted to evaluate the usefulness of Doppler sonography in the diagnosis of uterine vascular abnormality caused by previous D and E, and to report that transarterial embolization is an excellent treatment modality. We analyzed gray-scale US, color/duplex Doppler US and angiographic findings in seven patients with radiologically proven uterine vascular abnormality. Two of the seven cases were pseudoaneurysms and five of the seven cases were AVMs. n one of the AVMS, two small pseudoaneurysms were combined. In all cases, transarterial embolizations using 3 mm coil or/and gelfoam particles were performed. Follow-up US studies, including color Doppler US, were performed. on color/duplex Doppler sonography, two cases of pseudoaneurysm showed blood pools with turbulent arterial flow, and five cases of AVM showed asymmetrically increased cascularity, with vailable high velocities composed of the pulsatile arterial flow, with a high diastolic component. on angiography, the former showed pseudoaneruysmal sacs, and the latter densely opacified vascular tangles. No more abnormal uterine bleeding was shown following transarterial embolization in all cases. Color/duplex Doppler sonography was valuable in the diagnosis or treatment of abnormal uterine bleeding caused by uterine vascular abnormality such as acquired AVM or pseudoaneruysm

  18. Targeted hepatic sonography during clinic visits for detection of fatty liver in overweight children: a pilot study.

    Science.gov (United States)

    Perito, Emily R; Tsai, Patrika M; Hawley, Sarah; Lustig, Robert H; Feldstein, Vickie A

    2013-04-01

    The purpose of this study was to assess the feasibility and utility of targeted hepatic sonography to evaluate for hepatic steatosis during a subspecialty clinic visit. In this pilot study, we performed targeted hepatic sonography on 25 overweight children aged 7 to 17 years consecutively seen in a pediatric obesity clinic. Long-axis images of the right lobe of the liver and a split-screen image of liver and spleen were taken. Images were interpreted in real time by the radiologist and shown to the family. Demographics, clinical measurements, and laboratory parameters were also collected from the specialty clinic visit on the same day. Sonography required a median of 4 minutes during the visit (interquartile range, 3-5 minutes). All consented patients completed the study. The median alanine aminotransferase (ALT) level was 23 U/L in those with no steatosis (n = 14), 26 U/L with mild steatosis (n = 6), and 41 U/L with moderate/marked steatosis (n = 5). Children with ALT levels of 25 to 50 U/L had very variable sonographic measures of hepatic steatosis. When the participants were categorized by the overall degree of fatty liver, hepatic steatosis was significantly associated with the aspartate aminotransferase level (P = .028), ALT level (P = .003), and diastolic blood pressure (P = .05) but did not correlate with age, sex, Latino race, or insulin resistance. Targeted hepatic sonography added information not apparent from routine ALT screening and provided immediate feedback to clinicians and families about the effect of obesity on end organs. This examination could be a feasible, informative addition to screening for children at high risk for nonalcoholic fatty liver disease who are seen in clinics that specialize in obesity.

  19. Open-access transvaginal sonography in women of reproductive age with abnormal vaginal bleeding: a descriptive study in general practice

    NARCIS (Netherlands)

    de Vries, Corlien J. H.; Wieringa-de Waard, Margreet; Bindels, Patrick J. E.; Ankum, Willem M.

    2011-01-01

    Diagnostic ultrasonography is used by GPs in approximately 10% of patients of reproductive age with abnormal vaginal bleeding. Transvaginal sonography is recommended as a first-line diagnostic instrument for assessing uterine pathology. To assess if findings resulting from open-access sonography

  20. Pseudoaneurysm of the posterior circumflex humeral artery diagnosed by sonography

    DEFF Research Database (Denmark)

    Damgaard, Bodil; Court-Payen, Michel; Larsen, Lone

    2009-01-01

    with a painless, nonpulsatile mass in the posterior shoulder region and was suspected of a malignant soft-tissue tumor. Sonography, including power Doppler imaging, demonstrated a pseudoaneurysm, with the intralesional blood-filled cavity developed from the posterior circumflex humeral artery. The diagnosis...

  1. Contributions of scintigraphy and sonography to the diagnosis of traumatic splenic lesions in children

    International Nuclear Information System (INIS)

    Soucy, J.P.; Danais, S.; Filiatrault, D.; Lamoureux, J.; Lamoureux, F.

    1984-01-01

    20 children who were sent to the Nuclear Medicine and Sonography services for evaluation of the spleen in the context of a history of abdominal trauma were studied. All but one of the children were treated conservately, the exception having had on emergency renal procedure performed for renal rupture. The working diagnosis, based on the clinical that of splenic trauma in all cases. The result show a sensitivity of 90% (2 false negatives) for scintigraphy, and of 30% (14 false negatives) for sonography for the non-invasive diagnosis of splenic trauma in children [fr

  2. Contributions of scintigraphy and sonography to the diagnosis of traumatic splenic lesions in children

    Energy Technology Data Exchange (ETDEWEB)

    Soucy, J.P.; Danais, S.; Filiatrault, D.; Lamoureux, J.; Lamoureux, F. (Hopital Sainte-Justine, Montreal (Canada))

    1984-01-01

    20 children who were sent to the Nuclear Medicine and Sonography services for evaluation of the spleen in the context of a history of abdominal trauma were studied. All but one of the children were treated conservately, the exception having had on emergency renal procedure performed for renal rupture. The working diagnosis, based on the clinical, was that of splenic trauma in all cases. The results show a sensitivity of 90% (2 false negatives) for scintigraphy, and of 30% (14 false negatives) for sonography for the non-invasive diagnosis of splenic trauma in children.

  3. Ultra-high resolution protein crystallography

    International Nuclear Information System (INIS)

    Takeda, Kazuki; Hirano, Yu; Miki, Kunio

    2010-01-01

    Many protein structures have been determined by X-ray crystallography and deposited with the Protein Data Bank. However, these structures at usual resolution (1.5< d<3.0 A) are insufficient in their precision and quantity for elucidating the molecular mechanism of protein functions directly from structural information. Several studies at ultra-high resolution (d<0.8 A) have been performed with synchrotron radiation in the last decade. The highest resolution of the protein crystals was achieved at 0.54 A resolution for a small protein, crambin. In such high resolution crystals, almost all of hydrogen atoms of proteins and some hydrogen atoms of bound water molecules are experimentally observed. In addition, outer-shell electrons of proteins can be analyzed by the multipole refinement procedure. However, the influence of X-rays should be precisely estimated in order to derive meaningful information from the crystallographic results. In this review, we summarize refinement procedures, current status and perspectives for ultra high resolution protein crystallography. (author)

  4. Top ten pitfalls to avoid when performing musculoskeletal sonography: What you should know before entering the examination room

    International Nuclear Information System (INIS)

    Arend, Carlos Frederico

    2013-01-01

    Sonography has been used successfully to evaluate a number of musculoskeletal disorders. The method is operator dependent and familiarity with sonographic pitfalls greatly improves diagnostic accuracy and helps to optimize management. In this article, we discuss ten common pitfalls which can become a source of confusion and misdiagnosis in musculoskeletal sonography

  5. Contrast infusion sonography in the post-Essure setting.

    Science.gov (United States)

    Connor, Viviane

    2008-01-01

    To compare contrast infusion sonogram (CIS) to hysterosalpingogram (HSG) for use as a 3-month confirmation test after Essure. Pilot study (Canadian Task Force classification II-2). Healthy women in an academic multispecialty group. Seventeen women desiring permanent sterilization who had had successful bilateral Essure placement within 12 weeks. Contrast infusion sonography was performed and immediately followed by an HSG at the same appointment, between 1 and 12 weeks after Essure placement. To determine how well microinsert location and tubal status can be assessed with CIS, an adaptation of hysterosalpingo contrast sonography (HyCoSy), when compared with sequential HSG. Tubal occlusion rate within 4 to 8 weeks after Essure placement was also noted. All microinserts were readily identified with ultrasound, and location was accurately determined. In all patients (100%) with at least 1 tube patent on HSG, patency was also demonstrated on CIS by visualizing real-time flow in the tube or the presence of dye in the cul-de-sac or adnexa. There were no significant adverse events, and pain ratings were similar for both tests. The majority (88%) of patients felt strongly that they would prefer to have a 3-month confirmation test performed in the gynecologist's office rather than an unfamiliar radiologic facility. Tubal occlusion was noted on both CIS and HSG in 82% of patients before 12 weeks. Based on this pilot study with a small sample, CIS, an adaptation of HyCoSy, has comparable accuracy to HSG in the post-Essure setting. The safety, convenience, and comfort of an in-office test using ultrasound and a non-iodine-based dye would be a welcome alternative to HSG. There was also a high rate of bilateral fallopian tube occlusion noted on HSG at 4 weeks after Essure.

  6. The Significance of Brain Transcranial Sonography in Burning Mouth Syndrome: a Pilot Study

    Directory of Open Access Journals (Sweden)

    Iris Zavoreo

    2017-01-01

    Full Text Available Objective: Burning mouth syndrome (BMS is a chronic disorder which is affecting mostly postmenopausal women and is characterized by burning symptoms in the oral cavity on the clinically healthy oral mucosa. The results of previous studies suggested a possible role of peripheral and/or central neurological disturbances in these patients. The aim of this study was to analyze patients with burning mouth syndrome using transcranial sonography. Methods: By use of transcranial sonography of the brain parenchyma, substantia nigra, midbrain raphe and brain nucleus were evaluated in 20 patients with BMS (64.7±12.3 years and 20 controls with chronic pain in the lumbosacral region (61.5±15. Statistical analysis was performed by use of Student t test with significance set at p<0.05. Results: The results of this study have shown hypoechogenicity of the substantia nigra and midbrain raphe as well as hyperechogenicity of the brain nucleus in BMS patients (p<0,05 as compared to controls. Conclusions: Altered transcranial sonography findings of the brain parenchyma, midbrain raphe and brain nucleus in patients with burning mouth syndrome might reflect central disturbances within this syndrome.

  7. Real-time sonography in obstetrics.

    Science.gov (United States)

    Anderson, S G

    1978-03-01

    Three hundred fifty real-time scans were performed on pregnant women for various indications. Placental localization was satisfactorily obtained in 173 of 174 studies. Estimates of fetal gestation from directly measured biparietal diameter were +/-2 weeks of actual gestation in 153 of 172 (88.9%) measurements. The presence or absence of fetal motion and cardiac activity established a diagnosis of fetal viability or fetal death in 32 patients after the first trimester. Accurate diagnosis was made in 52 of 57 patients with threatened abortions, and two of these errors occurred in scans performed before completion of the eighth postmenstrual week. Because of the ability to demonstrate fetal motion, real-time sonography should have many applications in obstetrics.

  8. [Elastography as an additional tool in breast sonography. Technical principles and clinical applications].

    Science.gov (United States)

    Rjosk-Dendorfer, D; Reichelt, A; Clevert, D-A

    2014-03-01

    In recent years the use of elastography in addition to sonography has become a routine clinical tool for the characterization of breast masses. Whereas free hand compression elastography results in qualitative imaging of tissue stiffness due to induced compression, shear wave elastography displays quantitative information of tissue displacement. Recent studies have investigated the use of elastography in addition to sonography and improvement of specificity in differentiating benign from malignant breast masses could be shown. Therefore, additional use of elastography could help to reduce the number of unnecessary biopsies in benign breast lesions especially in category IV lesions of the ultrasound breast imaging reporting data system (US-BI-RADS).

  9. The role of whole body spiral CT in the primary work-up of polytrauma patients - comparison with conventional radiography and abdominal sonography

    International Nuclear Information System (INIS)

    Albrecht, T.; Schlippenbach, J. von; Wolf, K.J.; Stahel, P.F.; Ertel, W.

    2004-01-01

    Purpose: To evaluate the role of routine 'whole body spiral CT' in the primary work-up of polytrauma patients for injuries of the thorax, abdomen and spine, and to compare the results with those of conventional radiography of the chest and spine and abdominal ultrasound. Materials and Methods: Fifty consecutive polytrauma patients underwent contrast-enhanced single slice spiral CT (5 mm collimation) from the vertex to the floor of the pelvis as part of the primary work-up after emergency room admission. Overlapping high resolution sections and sagittal reformations of the spine were obtained. Reports of additional chest radiographs (n=43), abdominal ultrasound examinations (n=47) and spine radiographs (n=36) performed in the emergency room were available for retrospective comparison. The 'final diagnoses', which served as the standard of reference, were taken from the patients' records using all information that became available until discharge or death, such as findings from further imaging, surgery and autopsy. Results: CT showed 109 (97%) of 112 thoracic and abdominal soft-tissue injuries. Relevant injuries missed were an early splenic laceration and an early pelvic hematoma, both of which became clinically apparent several hours later. There were 4 false positive CT findings. Conventional chest radiography demonstrated only 20% of thoracic and sonography 22% of abdominal injuries. Chest radiography and sonography produced 2 false-positive findings each. CT showed 66 (87%) of 76 vertebral fractures including all 19 unstable ones. CT missed 5 anterior vertebral body and 5 spinous/transverse process fractures. Conventional radiography found 71% of vertebral fractures including only 50% of the unstable one. (orig.)

  10. High resolution solar observations

    International Nuclear Information System (INIS)

    Title, A.

    1985-01-01

    Currently there is a world-wide effort to develop optical technology required for large diffraction limited telescopes that must operate with high optical fluxes. These developments can be used to significantly improve high resolution solar telescopes both on the ground and in space. When looking at the problem of high resolution observations it is essential to keep in mind that a diffraction limited telescope is an interferometer. Even a 30 cm aperture telescope, which is small for high resolution observations, is a big interferometer. Meter class and above diffraction limited telescopes can be expected to be very unforgiving of inattention to details. Unfortunately, even when an earth based telescope has perfect optics there are still problems with the quality of its optical path. The optical path includes not only the interior of the telescope, but also the immediate interface between the telescope and the atmosphere, and finally the atmosphere itself

  11. High speed, High resolution terahertz spectrometers

    International Nuclear Information System (INIS)

    Kim, Youngchan; Yee, Dae Su; Yi, Miwoo; Ahn, Jaewook

    2008-01-01

    A variety of sources and methods have been developed for terahertz spectroscopy during almost two decades. Terahertz time domain spectroscopy (THz TDS)has attracted particular attention as a basic measurement method in the fields of THz science and technology. Recently, asynchronous optical sampling (AOS)THz TDS has been demonstrated, featuring rapid data acquisition and a high spectral resolution. Also, terahertz frequency comb spectroscopy (TFCS)possesses attractive features for high precision terahertz spectroscopy. In this presentation, we report on these two types of terahertz spectrometer. Our high speed, high resolution terahertz spectrometer is demonstrated using two mode locked femtosecond lasers with slightly different repetition frequencies without a mechanical delay stage. The repetition frequencies of the two femtosecond lasers are stabilized by use of two phase locked loops sharing the same reference oscillator. The time resolution of our terahertz spectrometer is measured using the cross correlation method to be 270 fs. AOS THz TDS is presented in Fig. 1, which shows a time domain waveform rapidly acquired on a 10ns time window. The inset shows a zoom into the signal with 100ps time window. The spectrum obtained by the fast Fourier Transformation (FFT)of the time domain waveform has a frequency resolution of 100MHz. The dependence of the signal to noise ratio (SNR)on the measurement time is also investigated

  12. High-Resolution Sonars: What Resolution Do We Need for Target Recognition?

    Directory of Open Access Journals (Sweden)

    Pailhas Yan

    2010-01-01

    Full Text Available Target recognition in sonar imagery has long been an active research area in the maritime domain, especially in the mine-counter measure context. Recently it has received even more attention as new sensors with increased resolution have been developed; new threats to critical maritime assets and a new paradigm for target recognition based on autonomous platforms have emerged. With the recent introduction of Synthetic Aperture Sonar systems and high-frequency sonars, sonar resolution has dramatically increased and noise levels decreased. Sonar images are distance images but at high resolution they tend to appear visually as optical images. Traditionally algorithms have been developed specifically for imaging sonars because of their limited resolution and high noise levels. With high-resolution sonars, algorithms developed in the image processing field for natural images become applicable. However, the lack of large datasets has hampered the development of such algorithms. Here we present a fast and realistic sonar simulator enabling development and evaluation of such algorithms.We develop a classifier and then analyse its performances using our simulated synthetic sonar images. Finally, we discuss sensor resolution requirements to achieve effective classification of various targets and demonstrate that with high resolution sonars target highlight analysis is the key for target recognition.

  13. Using modern teaching strategies to teach upper abdominal sonography to medical students

    Directory of Open Access Journals (Sweden)

    Wei-Chun Cheng

    2013-07-01

    Conclusion: We have greatly simplified the process of learning about upper abdominal sonography by using andragogy to enhance learning, mnemonics to help memory, and a pin-badge reward system to stimulate incentives.

  14. Optimization of Region of Interest Drawing for Quantitative Analysis: Differentiation Between Benign and Malignant Breast Lesions on Contrast-Enhanced Sonography.

    Science.gov (United States)

    Nakata, Norio; Ohta, Tomoyuki; Nishioka, Makiko; Takeyama, Hiroshi; Toriumi, Yasuo; Kato, Kumiko; Nogi, Hiroko; Kamio, Makiko; Fukuda, Kunihiko

    2015-11-01

    This study was performed to evaluate the diagnostic utility of quantitative analysis of benign and malignant breast lesions using contrast-enhanced sonography. Contrast-enhanced sonography using the perflubutane-based contrast agent Sonazoid (Daiichi Sankyo, Tokyo, Japan) was performed in 94 pathologically proven palpable breast mass lesions, which could be depicted with B-mode sonography. Quantitative analyses using the time-intensity curve on contrast-enhanced sonography were performed in 5 region of interest (ROI) types (manually traced ROI and circular ROIs of 5, 10, 15, and 20 mm in diameter). The peak signal intensity, initial slope, time to peak, positive enhancement integral, and wash-out ratio were investigated in each ROI. There were significant differences between benign and malignant lesions in the time to peak (P benign and malignant lesions in the time to peak (P benign and malignant breast lesions. © 2015 by the American Institute of Ultrasound in Medicine.

  15. Comparison of computerized tomography to sonography, applied in diseases of the pancreas

    International Nuclear Information System (INIS)

    Kluge, K.

    1982-01-01

    The examination results of 418 patients whose epigastria had been examined both by computerized tomography and sonography over 1 week in the time from beginning January 1978 until and of July 1979 were compared with regard to the imaging of the pancreas, reliability, and the specificity and sensitivity in establishing the diagnosis. For the sonographic examination, a compound and a real-time unit were used; the computerized tomography was carried out by means of an equipment of the 3rd generation with a scan time of 4 sec. The screening of the pancreas was significantly better using computerized tomography (99.3% US. 84% with US). As for accuracy, computerized tomography had 92.5% exact diagnoses versus 79.9% obtained by sonography. If, however, we look at the cases in which the pancreas could be screened with both methods the accuracy was almost the same (93.7 CT and 93.3% US). Specificity was almost of the same quality, however, the method of computerized tomography with 0.963 was slightly better than ultrasound with 0.943. As for sensitivity, sonography with 0.838 was better than CT with 0.721. The reason for that is the fact that a big part of the chronic pancreatites (30.3%) were not recognized by means of computerized tomography. (orig.) [de

  16. Duplex sonography in the planning and evaluation of arteriovenous fistulae for haemodialysis

    International Nuclear Information System (INIS)

    Kerr, S.F.; Krishan, S.; Lapham, R.C.; Weston, M.J.

    2010-01-01

    This paper describes how to perform duplex sonography in the planning and evaluation of arteriovenous fistulae in haemodialysis patients, discusses its roles in these settings, and presents a review of commonly encountered complications.

  17. Treatment response assessment of radiofrequency ablation for hepatocellular carcinoma: Usefulness of virtual CT sonography with magnetic navigation

    International Nuclear Information System (INIS)

    Minami, Yasunori; Kitai, Satoshi; Kudo, Masatoshi

    2012-01-01

    Purpose: Virtual CT sonography using magnetic navigation provides cross sectional images of CT volume data corresponding to the angle of the transducer in the magnetic field in real-time. The purpose of this study was to clarify the value of this virtual CT sonography for treatment response of radiofrequency ablation for hepatocellular carcinoma. Patients and methods: Sixty-one patients with 88 HCCs measuring 0.5–1.3 cm (mean ± SD, 1.0 ± 0.3 cm) were treated by radiofrequency ablation. For early treatment response, dynamic CT was performed 1–5 days (median, 2 days). We compared early treatment response between axial CT images and multi-angle CT images using virtual CT sonography. Results: Residual tumor stains on axial CT images and multi-angle CT images were detected in 11.4% (10/88) and 13.6% (12/88) after the first session of RFA, respectively (P = 0.65). Two patients were diagnosed as showing hyperemia enhancement after the initial radiofrequency ablation on axial CT images and showed local tumor progression shortly because of unnoticed residual tumors. Only virtual CT sonography with magnetic navigation retrospectively showed the residual tumor as circular enhancement. In safety margin analysis, 10 patients were excluded because of residual tumors. The safety margin more than 5 mm by virtual CT sonographic images and transverse CT images were determined in 71.8% (56/78) and 82.1% (64/78), respectively (P = 0.13). The safety margin should be overestimated on axial CT images in 8 nodules. Conclusion: Virtual CT sonography with magnetic navigation was useful in evaluating the treatment response of radiofrequency ablation therapy for hepatocellular carcinoma.

  18. Tc-99m DTPA perfusion scintigraphy and color coded duplex sonography in the evaluation of minimal renal allograft perfusion

    International Nuclear Information System (INIS)

    Bair, H.J.; Platsch, G.; Wolf, F.; Guenter, E.; Becker, D.; Rupprecht, H.; Neumayer, H.H.

    1997-01-01

    Aim: The clinical impact of perfusion scintigraphy versus color coded Duplex sonography was evaluated, with respect to their potential in assessing minimal allograft perfusion in vitally threatened kidney transplants, i.e. oligoanuric allografts suspected to have either severe rejection or thrombosis of the renal vein or artery. Methods: From July 1990 to August 1994 the grafts of 15 out of a total of 315 patients were vitally threatened. Technetium-99m DTPA scintigraphy and color coded Duplex sonography were performed in all patients. For scintigraphic evaluation of transplant perfusion analog scans up to 60 min postinjection, and time-activity curves over the first 60 sec after injection of 370-440 MBq Tc-99m diethylenetriaminepentaacetate acid (DTPA) were used and classified by a perfusion score, the time between renal and iliac artery peaks (TDiff) and the washout of the renogram curve. Additionally, evaluation of excretion function and assessment of vascular or urinary leaks were performed. By color coded Duplex sonography the perfusion in all sections of the graft as well as the vascular anastomoses were examined and the maximal blood flow velocity (Vmax) and the resistive index (RI) in the renal artery were determined by means of the pulsed Doppler device. Pathologic-anatomical diagnosis was achieved by either biopsy or post-explant histology in all grafts. Results: Scintigraphy and color coded Duplex sonography could reliably differentiate minimal (8/15) and not perfused (7/15) renal allografts. The results were confirmed either by angiography in digital subtraction technique (DSA) or the clinical follow up. Conclusion: In summary, perfusion scintigraphy and color coded Duplex sonography are comparable modalities to assess kidney graft perfusion. In clinical practice scintigraphy and colorcoded Doppler sonography can replace digital subtraction angiography in the evaluation of minimal allograft perfusion. (orig.) [de

  19. Berkeley High-Resolution Ball

    International Nuclear Information System (INIS)

    Diamond, R.M.

    1984-10-01

    Criteria for a high-resolution γ-ray system are discussed. Desirable properties are high resolution, good response function, and moderate solid angle so as to achieve not only double- but triple-coincidences with good statistics. The Berkeley High-Resolution Ball involved the first use of bismuth germanate (BGO) for anti-Compton shield for Ge detectors. The resulting compact shield permitted rather close packing of 21 detectors around a target. In addition, a small central BGO ball gives the total γ-ray energy and multiplicity, as well as the angular pattern of the γ rays. The 21-detector array is nearly complete, and the central ball has been designed, but not yet constructed. First results taken with 9 detector modules are shown for the nucleus 156 Er. The complex decay scheme indicates a transition from collective rotation (prolate shape) to single- particle states (possibly oblate) near spin 30 h, and has other interesting features

  20. Transcranial sonography and functional imaging in glucocerebrosidase mutation Parkinson disease.

    Science.gov (United States)

    Barrett, M J; Hagenah, J; Dhawan, V; Peng, S; Stanley, K; Raymond, D; Deik, A; Gross, S J; Schreiber-Agus, N; Mirelman, A; Marder, K; Ozelius, L J; Eidelberg, D; Bressman, S B; Saunders-Pullman, R

    2013-02-01

    Heterozygous glucocerebrosidase (GBA) mutations are the leading genetic risk factor for Parkinson disease, yet imaging correlates, particularly transcranial sonography, have not been extensively described. To determine whether GBA mutation heterozygotes with Parkinson disease demonstrate hyperechogenicity of the substantia nigra, transcranial sonography was performed in Ashkenazi Jewish Parkinson disease subjects, tested for the eight most common Gaucher disease mutations and the LRRK2 G2019S mutation, and in controls. [(18)F]-fluorodeoxyglucose or [(18)F]-fluorodopa positron emission tomography is also reported from a subset of Parkinson disease subjects with heterozygous GBA mutations. Parkinson disease subjects with heterozygous GBA mutations (n = 23) had a greater median maximal area of substantia nigral echogenicity compared to controls (n = 34, aSNmax = 0.30 vs. 0.18, p = 0.007). There was no difference in median maximal area of nigral echogenicity between Parkinson disease groups defined by GBA and LRRK2 genotype: GBA heterozygotes; GBA homozygotes/compound heterozygotes (n = 4, aSNmax = 0.27); subjects without LRRK2 or GBA mutations (n = 32, aSNmax = 0.27); LRRK2 heterozygotes/homozygotes without GBA mutations (n = 27, aSNmax = 0.28); and GBA heterozygotes/LRRK2 heterozygotes (n = 4, aSNmax = 0.32, overall p = 0.63). In secondary analyses among Parkinson disease subjects with GBA mutations, maximal area of nigral echogenicity did not differ based on GBA mutation severity or mutation number. [(18)F]-fluorodeoxyglucose (n = 3) and [(18)F]-fluorodopa (n = 2) positron emission tomography in Parkinson disease subjects with heterozygous GBA mutations was consistent with findings in idiopathic Parkinson disease. Both transcranial sonography and positron emission tomography are abnormal in GBA mutation associated Parkinson disease, similar to other Parkinson disease subjects. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. The Benefit of Sonography in Pregnancy-associated Breast Cancer

    International Nuclear Information System (INIS)

    Son, Eun Ju; Oh, Ki Keun; Kim, Eun Kyung

    2005-01-01

    To evaluate the sonographic, mammographic and MRI features of pregnancy-associated breast cancer with the major focus on the sonographic benefit in a diagnosis of pregnancy associated breast cancer. From 1998 to 2002, sonography was performed on a total 7 patients (age 23 to 38 years), who were pathologically diagnosed with breast cancer during pregnancy. Six of those patients underwent mammography. Five patients underwent a breast MRI, preoperatively. The radiological findings were evaluated retrospectively. Six patients underwent surgery and 1 patient underwent a core biopsy and chemotherapy. The histological, nuclear grading and pathological staging were evaluated. The sonographic findings showed a mass with irregular shapes (n=6), irregular margins (n=6), a non-parallel orientation (n=5), complex echo patterns (n=5). Associated findings could be observed in 3 patients, including Cooper's ligament thickening (n=2), edema (n=2), skin thickening (n=1) and axillary lymphadenopathy (n=3). The sonographic findings were positive and showed masses in 6 patients. All the patients had a dense breast in mammography. The mammographic findings included masses (n=4), masses with microcalcifications (n=2), masses with axillary lymphadenopathy (n=3), calcifications alone (n=1), an asymmetric density alone (n=1), extremely dense breasts with negative findings (n=2). A breast MRI showed an irregular shaped mass (n=4) with a rim-like enhancement (n=3), linear ductal enhancement without a mass (n= 1), and the time intensity cure revealed the typical pattern and level of enhancement in the carcinoma. Sonography is a valuable tool for diagnosing pregnancy-associated breast cancer. However, mammography should be performed if there is a suspicious lesion on sonography in order to confirm the pregnancy-associated breast cancer. Mammography has a lower sensitivity during pregnancy due to the physiologic changes in the breasts. However, calcifications and associated findings are helpful

  2. Rectal sonography before and after radiation treatment in inoperable cervical cancer

    International Nuclear Information System (INIS)

    Deutinger, J.; Bernaschek, G.; Tatra, G.

    1989-01-01

    Transrectal sonography is helpful in the classification of parametrial infiltration prior to treatment as well as in the follow-up. In this study, we performed rectal sonography in cases of inoperable cervical cancer to objectify the reduction of the infiltration of the uterine cervix and of the parametrium. Rectosonography was performed in 10 patients with histologically confirmed cancer of the uterine cervix before and after radiation treatment. The patients were treated with brachytherapy and teletherapy with an average radiation dose of 7680 rad. The whole therapy was finished after 6 to 9 weeks. Rectosonography enabled us to objectify the effect of radiation therapy. The length and width of parametrial infiltration could be measured in relation to the pelvis wall. Furthermore, the configuration of the parametrium could be imaged. Therefore, in cervical cancer, rectosonography is a valuable method to check and the documentate the effect of treatment and to diagnose recurrency. (orig.) [de

  3. Diagnosis of brain death by transcranial Doppler sonography.

    Science.gov (United States)

    Bode, H; Sauer, M; Pringsheim, W

    1988-12-01

    The blood flow velocities in the basal cerebral arteries can be recorded at any age by transcranial Doppler sonography. We examined nine children with either initial or developing clinical signs of brain death. Soon after successful resuscitation increased diastolic flow velocities indicated a probable decrease in cerebrovascular resistance; this was of no particular prognostic importance. As soon as there was a clinical deterioration, there was a reduction in flow velocities with retrograde flow during early diastole, probably due to an increase in cerebrovascular resistance; this indicated a doubtful prognosis. In eight of the nine children with clinical signs of brain death a typical reverberating flow pattern was found, which was characterised by a counterbalancing short forward flow in systole and a short retrograde flow in early diastole. This indicated arrest of cerebral blood flow. One newborn showed normal systolic and end diastolic flow velocities in the basal cerebral arteries for two days despite clinical and electroencephalographic signs of brain death. Shunting of blood through the circle of Willis without effective cerebral perfusion may explain this phenomenon. No patient had the typical reverberating flow pattern without being clinically brain dead. Transcranial Doppler sonography is a reliable technique, which can be used at the bedside for the confirmation or the exclusion of brain death in children in addition to the clinical examination.

  4. Middle cerebral artery vasospasm: transcranial color-coded duplex sonography versus conventional nonimaging transcranial Doppler sonography.

    Science.gov (United States)

    Swiat, Maciej; Weigele, John; Hurst, Robert W; Kasner, Scott E; Pawlak, Mikolaj; Arkuszewski, Michal; Al-Okaili, Riyadh N; Swiercz, Miroslaw; Ustymowicz, Andrzej; Opala, Grzegorz; Melhem, Elias R; Krejza, Jaroslaw

    2009-03-01

    To prospectively compare accuracies of transcranial color-coded duplex sonography (TCCS) and transcranial Doppler sonography (TCD) in the diagnosis of middle cerebral artery (MCA) vasospasm. Prospective blinded head-to-head comparison TCD and TCCS methods using digital subtraction angiography (DSA) as the reference standard. Department of Radiology in a tertiary university health center in a metropolitan area. Eighty-one consecutive patients (mean age, 53.9 +/- 13.9 years; 48 women). The indication for DSA was subarachnoid hemorrhage in 71 patients (87.6%), stroke or transient ischemic attack in five patients (6.2%), and other reasons in five patients (6.2%). The MCA was graded as normal, narrowed 50% using DSA. The accuracy of ultrasound methods was estimated by total area (Az) under receiver operator characteristic curve. To compare sensitivities of ultrasound methods, McNemar's test was used with mean velocity thresholds of 120 cm/sec for the detection of less advanced, and 200 cm/sec for the more advanced MCA narrowing. Angiographic MCA narrowing 50% in 10 of 135 arteries. Accuracy of TCCS was insignificantly higher than that of TCD in the detection of 50% narrowing, total Az for mean velocity being 0.83 +/- 0.05, 0.77 +/- 0.05, and 0.95 +/- 0.02, 0.86 +/- 0.08, respectively. Sensitivity of TCCS at commonly used threshold of 120 cm/sec for less advanced MCA spasm was significantly better than that of TCD at similar specificity, 55% vs. 39%, p = 0.038, whereas at a threshold of 200 cm/sec used for more advanced spasm, sensitivities and specificities of both methods were not different. The accuracy of TCCS and TCD is similar, but TCCS is more sensitive than TCD in the detection of MCA spasm. Sensitivity of both techniques in the detection of mild and more advanced spasm using 120 cm/sec and 200 cm/sec thresholds, respectively, is poor; however, a larger sample is required to increase precision of our sensitivity estimates.

  5. High-Resolution PET Detector. Final report

    International Nuclear Information System (INIS)

    Karp, Joel

    2014-01-01

    The objective of this project was to develop an understanding of the limits of performance for a high resolution PET detector using an approach based on continuous scintillation crystals rather than pixelated crystals. The overall goal was to design a high-resolution detector, which requires both high spatial resolution and high sensitivity for 511 keV gammas. Continuous scintillation detectors (Anger cameras) have been used extensively for both single-photon and PET scanners, however, these instruments were based on NaI(Tl) scintillators using relatively large, individual photo-multipliers. In this project we investigated the potential of this type of detector technology to achieve higher spatial resolution through the use of improved scintillator materials and photo-sensors, and modification of the detector surface to optimize the light response function.We achieved an average spatial resolution of 3-mm for a 25-mm thick, LYSO continuous detector using a maximum likelihood position algorithm and shallow slots cut into the entrance surface

  6. [Performances and place of sonography in the diagnostic of endometriosis: CNGOF-HAS Endometriosis Guidelines].

    Science.gov (United States)

    Philip, C-A; Dubernard, G

    2018-03-01

    Endometriosis is difficult to diagnose clinically. Transvaginal sonography (TVS) is a procedure that is known to be operator-dependent, which mean that published evidences has to be balanced with the level of the sonographer that produced the data. The objective of this publication was to assess the performances of the sonography in the diagnosis of endometriosis in order to establish the French national recommendations. We searched the MEDLINE database for publication from January 2000 to September 2017 using keywords associated with endometriosis and sonography. Eighty-four trial and reviews published in English or French were included. Ovarian endometrioma can usually be diagnosed by a non-expert sonographer, especially when its aspect is typical. In case of an ovarian cyst with atypical presentation, it is recommended to control the sonography by a referent or to perform an MRI. In menopaused women, any ovarian cyst should be considered as a cancer until proven otherwise. In the diagnosis of posterior deep invasive endometriosis (DIE), TVS with sensitivity and specificity of 96 and 99% respectively, seems at least equivalent if not superior to MRI. However, these performances are related to expert sonographers. To reach sufficient efficiency in posterior DIE, the estimated learning curve for a sonographer is 44 cases. When posterior DIE is suspected, we recommend proposing a TVS "performed by an expert" or a MRI "at least interpreted by an expert". In anterior DIE, TVS has a good specificity (100%), but its sensitivity is poor in the literature (64%). TVS is therefore not able to eliminate the diagnosis. However a renal ultrasound should be proposed each time a urinary endometriosis is confirmed, and should be considered whenever posterior DIE is diagnosed especially the lesion is superior to 3cm. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  7. Real-time virtual sonography (RVS)-guided vacuum-assisted breast biopsy for lesions initially detected with breast MRI.

    Science.gov (United States)

    Uematsu, Takayoshi

    2013-12-01

    To report on our initial experiences with a new method of real-time virtual sonography (RVS)-guided 11-gauge vacuum-assisted breast biopsy for lesions that were initially detected with breast MRI. RVS-guided 11-gauge vacuum-assisted biopsy is performed when a lesion with suspicious characteristics is initially detected with breast MRI and is occult on mammography, sonography, and physical examination. Live sonographic images were co-registered to the previously loaded second-look spine contrast-enhanced breast MRI volume data to correlate the sonography and MR images. Six lesions were examined in six consecutive patients scheduled to undergo RVS-guided 11-gauge vacuum-assisted biopsy. One patient was removed from the study because of non-visualization of the lesion in the second-look spine contrast-enhanced breast MRI. Five patients with non-mass enhancement lesions were biopsied. The lesions ranged in size from 9 to 13 mm (mean 11 mm). The average procedural time, including the sonography and MR image co-registration time, was 25 min. All biopsies resulted in tissue retrieval. One was fibroadenomatous nodules, and those of four were fibrocystic changes. There were no complications during or after the procedures. RVS-guided 11-gauge vacuum-assisted breast biopsies provide a safe and effective method for the examination of suspicious lesions initially detected with MRI.

  8. Clinical significance of neonatal parafrontal horn cysts detected by cranial sonography

    International Nuclear Information System (INIS)

    Woo, Jeong Joo; Jung, Myung Ja; Kim, Eun Ryung

    2005-01-01

    The describe the significance, incidence and characteristics of sonographic findings and long term outcomes of parafrontal horn cysts detected by screening cranial sonography done within the first week following birth. 2122 first cranial ultrasound scans performed over a five year period were retrospectively evaluated and 23 neonates with parafrontal horn cysts were found (which are different from secondary cystic lesions). 17 cases had a birth weight of 2400 gm with gestation between 34 and 41 weeks. The size, shape and location of the parafrontal horn cysts and other associated abnormalities shown on the cranial sonogram were evaluated and sequential ultrasound study, maternal records, neonatal events and neurodevelopmental evaluations were retrospectively assessed. Of the 23 subjects, 21 had isolated parafrontal horn cysts and 2 had subependymal hemorrhages. There was no record of any abnormal perinatal history. The cysts were bilateral in 20 neonates and unilateral in the others. The size of the cysts ranged from 3 to 18 mm in diameter (mean 9 mm). Sonographic features of the parafrontal horn cysts were distinctive morphology (elliptical, thin walled) and location (adjacent to the tip of the frontal horn). In 17 of the cases a follow-up cranial sonography was performed, and all parafrontal horn cysts disappeared within 3 to 6 months. Neurodevelopmental outcomes were normal in those 17 cases. Screening cranial sonography of neonates discovers isolated parafrontal horn cyst. The incidence of parafrontal horn cysts in neonates in our study was 1.1%. They are present in the first week following birth and resolve themselves without medical treatment within a few months. In addition, they show normal neurodevelopment. The parafrontal cysts are suspected to be a benign variant of normal neurodevelopment

  9. Locally advanced breast cancer: comparison of mammography, sonography and MR imaging in evaluation of residual disease in women receiving neoadjuvant chemotherapy

    International Nuclear Information System (INIS)

    Londero, Viviana; Bazzocchi, Massimo; Del Frate, Chiara; Francescutti, Giuliana; Zuiani, Chiara; Puglisi, Fabio; Di Loreto, Carla

    2004-01-01

    The accuracy of mammography, sonography and magnetic resonance imaging (MRI) in identifying residual disease after neoadjuvant chemotherapy is evaluated and imaging findings are correlated with pathologic findings. Fifteen patients enrolled in an experimental protocol of preoperative neoadjuvant chemotherapy underwent clinical examination, mammography, sonography and dynamic MRI, performed in this order, before and respectively after 2 and 4 cycles of neoadjuvant chemotherapy. Four radiologists, two for mammography, one for sonography and one for MR, examined the images, blinded to the results of the other examinations. All patients underwent radical or conservative surgery, and imaging findings were compared with pathologic findings. MRI identified 2/15 (13.3.%) clinically complete response (CR), 9/15 (60%) partial response (PR), 3/15 (20%) stable disease (SD) and 1/15 (6.7%) progressive disease. Mammography identified 1/15 (6.7%) clinically CR, 8/15 (53.3%) PR and 4/15 (27%) SD, and was not able to evaluate the disease in 2/15 (13%) cases. Sonography presented the same results as MRI. Therefore, MRI and sonography compared to mammography correctly identified residual disease in 100 vs. 86%. MRI resulted in two false-negative results because of the presence of microfoci of in situ ductal carcinoma (DCIS) and invasive lobular carcinoma (LCI). MRI was superior to mammography in cases of multifocal or multicentric disease (83 vs. 33%). Sonography performed after MRI improves the accuracy in evaluation of uncertain foci of multifocal disease seen on MR images with an increase of diagnostic accuracy from 73 to 84.5%. MRI assesses response to neoadjuvant chemotherapy better than traditional methods of physical examination and mammography. (orig.)

  10. Locally advanced breast cancer: comparison of mammography, sonography and MR imaging in evaluation of residual disease in women receiving neoadjuvant chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Londero, Viviana; Bazzocchi, Massimo; Del Frate, Chiara; Francescutti, Giuliana; Zuiani, Chiara [Institute of Radiology, University of Udine, via Colugna 50, 33100, Udine (Italy); Puglisi, Fabio [Department of Oncology, University of Udine, via Colugna 50, 33100, Udine (Italy); Di Loreto, Carla [Institute of Pathology, University of Udine, via Colugna 50, 33100, Udine (Italy)

    2004-08-01

    The accuracy of mammography, sonography and magnetic resonance imaging (MRI) in identifying residual disease after neoadjuvant chemotherapy is evaluated and imaging findings are correlated with pathologic findings. Fifteen patients enrolled in an experimental protocol of preoperative neoadjuvant chemotherapy underwent clinical examination, mammography, sonography and dynamic MRI, performed in this order, before and respectively after 2 and 4 cycles of neoadjuvant chemotherapy. Four radiologists, two for mammography, one for sonography and one for MR, examined the images, blinded to the results of the other examinations. All patients underwent radical or conservative surgery, and imaging findings were compared with pathologic findings. MRI identified 2/15 (13.3.%) clinically complete response (CR), 9/15 (60%) partial response (PR), 3/15 (20%) stable disease (SD) and 1/15 (6.7%) progressive disease. Mammography identified 1/15 (6.7%) clinically CR, 8/15 (53.3%) PR and 4/15 (27%) SD, and was not able to evaluate the disease in 2/15 (13%) cases. Sonography presented the same results as MRI. Therefore, MRI and sonography compared to mammography correctly identified residual disease in 100 vs. 86%. MRI resulted in two false-negative results because of the presence of microfoci of in situ ductal carcinoma (DCIS) and invasive lobular carcinoma (LCI). MRI was superior to mammography in cases of multifocal or multicentric disease (83 vs. 33%). Sonography performed after MRI improves the accuracy in evaluation of uncertain foci of multifocal disease seen on MR images with an increase of diagnostic accuracy from 73 to 84.5%. MRI assesses response to neoadjuvant chemotherapy better than traditional methods of physical examination and mammography. (orig.)

  11. The masked educator-innovative simulation in an Australian undergraduate Medical Sonography and Medical Imaging program.

    Science.gov (United States)

    Reid-Searl, Kerry; Bowman, Anita; McAllister, Margaret; Cowling, Cynthia; Spuur, Kelly

    2014-12-01

    Clinical learning experiences for sonography and medical imaging students can sometimes involve the practice of technical procedures with less of a focus on developing communication skills with patients. Whilst patient-based simulation scenarios have been widely reported in other health education programmes, there is a paucity of research in sonography and medical imaging. The aim of this study was to explore the effectiveness of Mask-Ed™ (KRS Simulation) in the learning and teaching of clinical communication skills to undergraduate medical sonography and medical imaging students. Mask-Ed™ (KRS Simulation) is a simulation technique where the educator is hidden behind wearable realistic silicone body props including masks. Focus group interviews were conducted with 11 undergraduate medical sonography and medical imaging students at CQUniversity, Australia. The number of participants was limited to the size of the cohort of students enrolled in the course. Prior to these interviews participants were engaged in learning activities that featured the use of the Mask-Ed™ (KRS Simulation) method. Thematic analysis was employed to explore how the introduction of Mask-Ed™ (KRS Simulation) contributed to students' learning in relation to clinical communication skills. Key themes included: benefits of interacting with someone real rather than another student, learning made fun, awareness of empathy, therapeutic communication skills, engaged problem solving and purposeful reflection. Mask-Ed™ (KRS Simulation) combined with interactive sessions with an expert facilitator, contributed positively to students' learning in relation to clinical communication skills. Participants believed that interacting with someone real, as in the Mask-Ed characters was beneficial. In addition to the learning being described as fun, participants gained an awareness of empathy, therapeutic communication skills, engaged problem solving and purposeful reflection.

  12. Prenatal diagnosis of the Dandy-Walker syndrome by sonography and computed tomography

    International Nuclear Information System (INIS)

    Toelly, E.; Ebner, F.; Oberbauer, R.W.

    1984-01-01

    A case of Dandy-Walker-syndrome is presented, comparing the value of sonography and CT in intrauterine diagnosis. Together with a review of the literature of the subject, pathogenesis, morphology and prognosis in regard to the psychomotoric development are discussed. (orig.) [de

  13. High resolution sequence stratigraphy in China

    International Nuclear Information System (INIS)

    Zhang Shangfeng; Zhang Changmin; Yin Yanshi; Yin Taiju

    2008-01-01

    Since high resolution sequence stratigraphy was introduced into China by DENG Hong-wen in 1995, it has been experienced two development stages in China which are the beginning stage of theory research and development of theory research and application, and the stage of theoretical maturity and widely application that is going into. It is proved by practices that high resolution sequence stratigraphy plays more and more important roles in the exploration and development of oil and gas in Chinese continental oil-bearing basin and the research field spreads to the exploration of coal mine, uranium mine and other strata deposits. However, the theory of high resolution sequence stratigraphy still has some shortages, it should be improved in many aspects. The authors point out that high resolution sequence stratigraphy should be characterized quantitatively and modelized by computer techniques. (authors)

  14. Development of AMS high resolution injector system

    International Nuclear Information System (INIS)

    Bao Yiwen; Guan Xialing; Hu Yueming

    2008-01-01

    The Beijing HI-13 tandem accelerator AMS high resolution injector system was developed. The high resolution energy achromatic system consists of an electrostatic analyzer and a magnetic analyzer, which mass resolution can reach 600 and transmission is better than 80%. (authors)

  15. Resolution enhancement of low quality videos using a high-resolution frame

    NARCIS (Netherlands)

    Pham, T.Q.; Van Vliet, L.J.; Schutte, K.

    2006-01-01

    This paper proposes an example-based Super-Resolution (SR) algorithm of compressed videos in the Discrete Cosine Transform (DCT) domain. Input to the system is a Low-Resolution (LR) compressed video together with a High-Resolution (HR) still image of similar content. Using a training set of

  16. Differentiation of widely invasive and minimally invasive follicular thyroid carcinoma with sonography

    International Nuclear Information System (INIS)

    Shin, Jung Hee; Han, Boo-Kyung; Ko, Eun Young; Oh, Young Lyun; Kim, Jung Han

    2010-01-01

    Purpose: We evaluated the sonographic findings that can help differentiate widely invasive follicular thyroid carcinomas (WIFTC) from minimally invasive follicular thyroid carcinomas (MIFTC). Methods: We retrospectively compared the sonographic and clinical findings of 24 patients (M:F = 5:19) with 24 MIFTCs and 12 patients (M:F = 1:11) with 13 WIFTCs that were confirmed pathologically and available in sonography at our institution between 1995 and 2007. Results: WIFTC was more common in elderly patients than MIFTC (p < 0.0001). WIFTC was seen with a larger size than MIFTC (p = 0.0092). The best cut-off values for age and size were 49 years and 5.6 cm, respectively. On sonography, all tumors were seen as a well-defined oval or round mass. Heterogeneous mulberry-like echotexture was more common for WIFTC than for MIFTC (77% vs. 25%) (p = 0.0046). The presence of calcifications was more frequent in WIFTC than in MIFTC (54% vs. 8%) (p = 0.0041). Ring calcifications (86%) were the most common type for WIFTC. WIFTC was commonly hypoechoic (70%) and rarely cystic change (8%), but without statistical differences. When WIFTCs represented tumors with two or more findings with a statistical difference, the specificity was 96%. Conclusion: WIFTC is distinguishable from MIFTC by sonography for patients with an age ≥49 years, a tumor ≥5.6 cm, a heterogeneous mulberry-like echotexure, or the presence of calcifications. The sonographic impression of a WIFTC can support a preoperative or intraoperative diagnosis of a difficult case as determined by FNA or with a frozen section.

  17. High resolution, high speed ultrahigh vacuum microscopy

    International Nuclear Information System (INIS)

    Poppa, Helmut

    2004-01-01

    The history and future of transmission electron microscopy (TEM) is discussed as it refers to the eventual development of instruments and techniques applicable to the real time in situ investigation of surface processes with high resolution. To reach this objective, it was necessary to transform conventional high resolution instruments so that an ultrahigh vacuum (UHV) environment at the sample site was created, that access to the sample by various in situ sample modification procedures was provided, and that in situ sample exchanges with other integrated surface analytical systems became possible. Furthermore, high resolution image acquisition systems had to be developed to take advantage of the high speed imaging capabilities of projection imaging microscopes. These changes to conventional electron microscopy and its uses were slowly realized in a few international laboratories over a period of almost 40 years by a relatively small number of researchers crucially interested in advancing the state of the art of electron microscopy and its applications to diverse areas of interest; often concentrating on the nucleation, growth, and properties of thin films on well defined material surfaces. A part of this review is dedicated to the recognition of the major contributions to surface and thin film science by these pioneers. Finally, some of the important current developments in aberration corrected electron optics and eventual adaptations to in situ UHV microscopy are discussed. As a result of all the path breaking developments that have led to today's highly sophisticated UHV-TEM systems, integrated fundamental studies are now possible that combine many traditional surface science approaches. Combined investigations to date have involved in situ and ex situ surface microscopies such as scanning tunneling microscopy/atomic force microscopy, scanning Auger microscopy, and photoemission electron microscopy, and area-integrating techniques such as x-ray photoelectron

  18. A high resolution solar atlas for fluorescence calculations

    Science.gov (United States)

    Hearn, M. F.; Ohlmacher, J. T.; Schleicher, D. G.

    1983-01-01

    The characteristics required of a solar atlas to be used for studying the fluorescence process in comets are examined. Several sources of low resolution data were combined to provide an absolutely calibrated spectrum from 2250 A to 7000A. Three different sources of high resolution data were also used to cover this same spectral range. The low resolution data were then used to put each high resolution spectrum on an absolute scale. The three high resolution spectra were then combined in their overlap regions to produce a single, absolutely calibrated high resolution spectrum over the entire spectral range.

  19. Clinical significance of neonatal parafrontal horn cysts detected by cranial sonography

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Jeong Joo [Eulji University of Medicine, Daejeon (Korea, Republic of); Jung, Myung Ja [Sanggye Paik Hospital, Inje University of Medicine, Seoul (Korea, Republic of); Kim, Eun Ryung [Sungae General Hospital, Seoul (Korea, Republic of)

    2005-07-15

    The describe the significance, incidence and characteristics of sonographic findings and long term outcomes of parafrontal horn cysts detected by screening cranial sonography done within the first week following birth. 2122 first cranial ultrasound scans performed over a five year period were retrospectively evaluated and 23 neonates with parafrontal horn cysts were found (which are different from secondary cystic lesions). 17 cases had a birth weight of < 2400 gm with gestation between 30 and 35 weeks, 6 cases had a birth weight of > 2400 gm with gestation between 34 and 41 weeks. The size, shape and location of the parafrontal horn cysts and other associated abnormalities shown on the cranial sonogram were evaluated and sequential ultrasound study, maternal records, neonatal events and neurodevelopmental evaluations were retrospectively assessed. Of the 23 subjects, 21 had isolated parafrontal horn cysts and 2 had subependymal hemorrhages. There was no record of any abnormal perinatal history. The cysts were bilateral in 20 neonates and unilateral in the others. The size of the cysts ranged from 3 to 18 mm in diameter (mean 9 mm). Sonographic features of the parafrontal horn cysts were distinctive morphology (elliptical, thin walled) and location (adjacent to the tip of the frontal horn). In 17 of the cases a follow-up cranial sonography was performed, and all parafrontal horn cysts disappeared within 3 to 6 months. Neurodevelopmental outcomes were normal in those 17 cases. Screening cranial sonography of neonates discovers isolated parafrontal horn cyst. The incidence of parafrontal horn cysts in neonates in our study was 1.1%. They are present in the first week following birth and resolve themselves without medical treatment within a few months. In addition, they show normal neurodevelopment. The parafrontal cysts are suspected to be a benign variant of normal neurodevelopment.

  20. Combined Use of Ultrasound Elastography and B-Mode Sonography for Differentiation of Benign and Malignant Circumscribed Breast Masses.

    Science.gov (United States)

    Kim, Soo-Yeon; Park, Jeong Seon; Koo, Hye Ryoung

    2015-11-01

    To evaluate the diagnostic performance of combined B-mode sonography and ultrasound elastography for differentiation between benign and malignant breast masses with circumscribed margins. We analyzed 109 pathologically proven circumscribed breast masses. Two radiologists retrospectively reviewed B-mode sonograms and elastograms in consensus. Based on the American College of Radiology Breast Imaging Reporting and Data System, we determined categories of the masses on B-mode sonography. Elastographic scores were assessed by a 3-point scale (negative, 0; equivocal, 1; and positive, 2). When the elastographic score for a lesion was 0 or 2, we downgraded or upgraded the B-mode category, respectively; thus, the reclassified Breast Imaging Reporting and Data System category was defined as the "reclassification category." Mean category values for benign and malignant lesions were compared by a Student t test. The diagnostic performance of B-mode, elastographic, and reclassification assessments was compared by receiver operating characteristic curve analysis. The mean B-mode category (2.5 versus 1.7), elastographic score (1.7 versus 0.8), and reclassification category (3.2 versus 1.6) were significantly higher in malignant than benign lesions (P benign and malignant circumscribed breast masses, combined use of B-mode sonography and elastography could provide a better diagnostic performance than B-mode sonography alone. © 2015 by the American Institute of Ultrasound in Medicine.

  1. High-resolution SPECT for small-animal imaging

    International Nuclear Information System (INIS)

    Qi Yujin

    2006-01-01

    This article presents a brief overview of the development of high-resolution SPECT for small-animal imaging. A pinhole collimator has been used for high-resolution animal SPECT to provide better spatial resolution and detection efficiency in comparison with a parallel-hole collimator. The theory of imaging characteristics of the pinhole collimator is presented and the designs of the pinhole aperture are discussed. The detector technologies used for the development of small-animal SPECT and the recent advances are presented. The evolving trend of small-animal SPECT is toward a multi-pinhole and a multi-detector system to obtain a high resolution and also a high detection efficiency. (authors)

  2. Is sonography performed by the rheumatologist as useful as arthrography executed by the radiologist for the assessment of full thickness rotator cuff tears?

    NARCIS (Netherlands)

    Swen, W. A.; Jacobs, J. W.; Neve, W. C.; Bal, D.; Bijlsma, J. W.

    1998-01-01

    Sonography and arthrography are techniques used to detect rotator cuff tears (RCT). The diagnostic value of sonography executed by a rheumatologist versus that of arthrography performed by a radiologist for assessment of RCT was investigated among patients with unilateral chronic shoulder complaints

  3. Preoperative assessment of intestinal endometriosis: A comparison of transvaginal sonography with water-contrast in the rectum, transrectal sonography, and barium enema.

    Science.gov (United States)

    Bergamini, Valentino; Ghezzi, Fabio; Scarperi, Stefano; Raffaelli, Ricciarda; Cromi, Antonella; Franchi, Massimo

    2010-12-01

    To evaluate the accuracy of Transrectal Sonography (TRS) and a new technique, Transvaginal Sonography with Water-Contrast in the Rectum (RWC-TVS), in the diagnosis of rectosigmoid endometriosis, and the accuracy of Barium Enema (BE) and RWC-TVS in the detection of intestinal stenosis due to endometriosis. In a prospective study, we compared the findings of TRS and RWC-TVS performed before surgery with the operative and pathologic findings in 61 consecutive patients who underwent laparoscopy or laparotomy for suspected rectosigmoid endometriosis. The accuracy of BE and RWC-TVS in the detection of intestinal stenosis was evaluated comparing the radiologic and ultrasonographic results with the macroscopic findings at surgery and pathology. RWC-TVS diagnosed rectosigmoid endometriosis with the same accuracy of TRS and was equally efficient as BE in the detection of a significant intestinal lumen stenosis. For the diagnosis of rectosigmoid endometriosis the sensitivity, specificity, positive and negative predictive values of TRS and RWC-TVS were 88.2% and 96%, 80%, and 90%, 95.7%, and 98%, and 57.1% and 81.8%, respectively. For the detection of intestinal stenosis the sensitivity, specificity, positive and negative predictive values of BE and RWC-TVS were 93.7% and 87.5%, 94.2% and 91.4%, 88.2% and 82.3%, and 97% and 94.1%, respectively. RWC-TVS is a new, simple technique for a single-step and accurate preoperative assessment of rectosigmoid endometriosis.

  4. Color coded duplex sonography. Interdisciplinary vascular ultrasonography; Farbkodierte Duplexsonographie. Interdisziplinaerer vaskulaerer Ultraschall

    Energy Technology Data Exchange (ETDEWEB)

    Kubale, R. [Institut fuer Radiologie, Sonographie und Nuklearmedizin, Pirmasens (Germany); Stiegler, H. [Staedtisches Krankenhaus Schwabing, Muenchen (Germany). 7. Medizinische Abt.

    2002-07-01

    An interdisciplinary team of experts impart the state of the art in color coded duplex sonography applied for examination of all anatomic areas. Detailed information is given for every vascular area, describing the examination procedure, possible origins of mistakes or faults, and means to avoid them. In addition to the classical applications, eg. for examination of the extra- and intracranial vessels, vessels of the limbs, visceral vessels and the vessels of liver and kidney, there are chapters devoted to: haemodialysis shunts, arteriovenous malformations, duplex sonography of the penis, tumor vascularisation. (orig./CB) [German] Ein interdisziplinaeres Autorenteam vermittelt Ihnen den State of the Art der FKDS fuer alle anatomischen Regionen. Fuer jede der Gefaessregionen werden detaillierte Angaben zum Untersuchungsablauf, zu moeglichen Fehlerquellen und zu deren Vermeidung geboten. Neben den klassischen Anwendungen bei der Untersuchung - der extra- und intrakraniellen Gefaesse, - der Extremitaetengefaesse, - der viszeralen Gefaesse sowie der Gefaesse von Niere und Leber finden Sie Kapitel zu den Themen: Haemodialyseshunt, arteriovenoese Malformationen, Duplexsonographie des Penis und Tumorvaskularisation. (orig./AJ)

  5. Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography

    International Nuclear Information System (INIS)

    Byun, Sung Su; Kim, Youn Jeong; Chun, Yong Sun; Kim, Won Hong; Kim, Jeong Ho; Park, Chul Hi

    2008-01-01

    This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. The z-axis length (mean±standard deviation) of the beam hardening artifact was 4.5±0.8 cm in the arthroplastic knees and 3.9±2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating postarthroplasty patients

  6. Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Sung Su; Kim, Youn Jeong; Chun, Yong Sun; Kim, Won Hong [Inha University, College of Medicine, Incheon (Korea, Republic of); Kim, Jeong Ho; Park, Chul Hi [Gachon University, Gil Medical Center, Incheon (Korea, Republic of)

    2008-02-15

    This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. The z-axis length (mean{+-}standard deviation) of the beam hardening artifact was 4.5{+-}0.8 cm in the arthroplastic knees and 3.9{+-}2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating postarthroplasty patients.

  7. Tumor vascularity of experimentally induced VX2 carcinoma in the rabbit thigh: evaluation with enhanced power doppler sonography and DSA correlated with histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hoon; Han, Joon Koo; Chung, Jin Wook; Lee, Kyoung Ho; Kim, Se Hyung; Kim, Seog Joon; Choi, Byung Ihn; Chang, Kee Hyun [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2002-05-01

    To describe findings of enhanced power Doppler sonography and DSA in experimentally induced VX2 carcinomas in rabbit thigh and to correlate the imaging findings with the histopathologic features. A total of 30 VX2 carcinomas were implanted in rabbit thigh, and after conventional and enhanced power Doppler sonography and DSA, histopathologic examination was performed. Enhanced power Doppler sonography and DSA, were used to determine the distribution pattern of tumor vascularity; to assess its grade and the percentage of a tumor area occupied by vessels, conventional and enhanced power Doppler sonography, as well as DSA, were used. The grade of necrosis and the development of fibrovascular stroma and capsule were histopathologically determined. The findings of power Doppler sonography were compared with those of DSA and the imaging features were correlated with the histopathologic features. At enhanced power Doppler sonography, the signal was either avascular (n=9), peripheral (n=15) or diffuse (n=6), while at DSA, the corresponding totals were eight, fourteen and eight. There was statistically significant corelation between enhanced power Doppler sonogrpahy and DSA, both in their depiction of the distribution of patterns of tumor vascularity and as regards their findings of grade and percentage of vascular area. As determined by both conventional and enhanced power Doppler sonogrpahy, and by DSA, grade of necrosis and the development of fibrovascular stroma and a capsule correlated with grade and the percentage of vascular area. Experimentally induced VX2 carcinomas in rabbit thigh demonstrated various patterns of tumor vascularity, and the findings of enhanced power Doppler sonography correlated with those of DSA. Tumor vascularity, as demonstrated by two imaging modalities, correlated closely with grade of necrosis and the development of fibrovascular stroma and a capsule, as revealed by histopathologic examination.

  8. Tumor vascularity of experimentally induced VX2 carcinoma in the rabbit thigh: evaluation with enhanced power doppler sonography and DSA correlated with histopathologic findings

    International Nuclear Information System (INIS)

    Kim, Young Hoon; Han, Joon Koo; Chung, Jin Wook; Lee, Kyoung Ho; Kim, Se Hyung; Kim, Seog Joon; Choi, Byung Ihn; Chang, Kee Hyun

    2002-01-01

    To describe findings of enhanced power Doppler sonography and DSA in experimentally induced VX2 carcinomas in rabbit thigh and to correlate the imaging findings with the histopathologic features. A total of 30 VX2 carcinomas were implanted in rabbit thigh, and after conventional and enhanced power Doppler sonography and DSA, histopathologic examination was performed. Enhanced power Doppler sonography and DSA, were used to determine the distribution pattern of tumor vascularity; to assess its grade and the percentage of a tumor area occupied by vessels, conventional and enhanced power Doppler sonography, as well as DSA, were used. The grade of necrosis and the development of fibrovascular stroma and capsule were histopathologically determined. The findings of power Doppler sonography were compared with those of DSA and the imaging features were correlated with the histopathologic features. At enhanced power Doppler sonography, the signal was either avascular (n=9), peripheral (n=15) or diffuse (n=6), while at DSA, the corresponding totals were eight, fourteen and eight. There was statistically significant corelation between enhanced power Doppler sonogrpahy and DSA, both in their depiction of the distribution of patterns of tumor vascularity and as regards their findings of grade and percentage of vascular area. As determined by both conventional and enhanced power Doppler sonogrpahy, and by DSA, grade of necrosis and the development of fibrovascular stroma and a capsule correlated with grade and the percentage of vascular area. Experimentally induced VX2 carcinomas in rabbit thigh demonstrated various patterns of tumor vascularity, and the findings of enhanced power Doppler sonography correlated with those of DSA. Tumor vascularity, as demonstrated by two imaging modalities, correlated closely with grade of necrosis and the development of fibrovascular stroma and a capsule, as revealed by histopathologic examination

  9. Diagnosis of Pentalogy of Cantrell in the First Trimester Using Transvaginal Sonography and Color Doppler

    Directory of Open Access Journals (Sweden)

    Ayşe Figen Türkçapar

    2015-01-01

    Full Text Available We report the prenatal diagnosis of Cantrell syndrome in the first trimester. During a routine transabdominal ultrasonographic examination, a midline supraumbilical abdominal wall defect including herniated liver and ectopia cordis with a large omphalocele containing the intestines and cystic hygroma was incidentally identified at the 12th week of gestation. A transvaginal sonography examination revealed a severe lumbosacral scoliosis in addition to the inability to visualize the abdominal aorta which was indicative of a severe intracardiac defect. The parents opted for pregnancy to be terminated. In this case report, we discuss the complementary role of transvaginal sonography and Doppler imaging in the diagnosis of Cantrell syndrome in early pregnancy.

  10. Effectiveness of sonography assisted minimal invasive plate osteosynthesis (MIPO) compare with fluoroscope assisted in femoral shaft fracture: A cadaveric study.

    Science.gov (United States)

    Saengsin, Jirawat; Vaseenon, Tanawat; Pattamapaspong, Nuttaya; Kritsaneephaiboon, Apipop

    2017-08-01

    A minimal invasive plate osteosynthesis (MIPO) has an advantage of biological soft tissue preservation that consists of preserving bony blood supply, fracture hematoma and less soft tissue damage which leads to decreasing of infection rate and rapid bone healing. However, the radiation exposure is still a disadvantage of this technique. A sonography that provides dynamic real time imaging may be used as an alternative technique for assisting MIPO. The aim of this study was to compare the effectiveness of MIPO in femoral shaft fracture between the sonography assisted and the fluoroscopy assisted. Twenty-eight cadaveric limbs were subjected to create femoral shaft fracture. Then, sonography assisted reduction with temporary external fixation and MIPO were performed. Images of the sonography and the fluoroscopy were recorded including before reduction, after reduction and after MIPO in order to identify fracture displacements in anteroposterior and mediolateral directions. Moreover, the anterior and posterior distances from edge of the bone to the plate were measured to confirm plate position. The effectiveness of this technique was defined as the proper plate position and acceptable alignment after fixation. All distances from the sonography and the fluoroscopy were also analyzed and compared using Pearson correlation and Bland-Altman method to assess the agreements between two tests. All of the subjects were met the criteria for acceptable alignment. We found only three femoral shaft fracture (11%) operated with MIPO by sonography assisted that showed slipped plate off femoral bones. According to Pearson correlation, there were good to excellent agreements in term of measuring fracture displacement before (Pearson Correlation >0.7) and after reduction (Pearson Correlation >0.7) between these two tests. There was moderate agreement regarding to evaluation of plate position (Pearson Correlation 03.-0.7). When we compared two methods of measurement using Bland

  11. High resolution time integration for SN radiation transport

    International Nuclear Information System (INIS)

    Thoreson, Greg; McClarren, Ryan G.; Chang, Jae H.

    2009-01-01

    First-order, second-order, and high resolution time discretization schemes are implemented and studied for the discrete ordinates (S N ) equations. The high resolution method employs a rate of convergence better than first-order, but also suppresses artificial oscillations introduced by second-order schemes in hyperbolic partial differential equations. The high resolution method achieves these properties by nonlinearly adapting the time stencil to use a first-order method in regions where oscillations could be created. We employ a quasi-linear solution scheme to solve the nonlinear equations that arise from the high resolution method. All three methods were compared for accuracy and convergence rates. For non-absorbing problems, both second-order and high resolution converged to the same solution as the first-order with better convergence rates. High resolution is more accurate than first-order and matches or exceeds the second-order method

  12. High tracking resolution detectors. Final Technical Report

    International Nuclear Information System (INIS)

    Vasile, Stefan; Li, Zheng

    2010-01-01

    High-resolution tracking detectors based on Active Pixel Sensor (APS) have been valuable tools in Nuclear Physics and High-Energy Physics research, and have contributed to major discoveries. Their integration time, radiation length and readout rate is a limiting factor for the planed luminosity upgrades in nuclear and high-energy physics collider-based experiments. The goal of this program was to demonstrate and develop high-gain, high-resolution tracking detector arrays with faster readout, and shorter radiation length than APS arrays. These arrays may operate as direct charged particle detectors or as readouts of high resolution scintillating fiber arrays. During this program, we developed in CMOS large, high-resolution pixel sensor arrays with integrated readout, and reset at pixel level. Their intrinsic gain, high immunity to surface and moisture damage, will allow operating these detectors with minimal packaging/passivation requirements and will result in radiation length superior to APS. In Phase I, we designed and fabricated arrays with calorimetric output capable of sub-pixel resolution and sub-microsecond readout rate. The technical effort was dedicated to detector and readout structure development, performance verification, as well as to radiation damage and damage annealing.

  13. Ultra high resolution tomography

    Energy Technology Data Exchange (ETDEWEB)

    Haddad, W.S.

    1994-11-15

    Recent work and results on ultra high resolution three dimensional imaging with soft x-rays will be presented. This work is aimed at determining microscopic three dimensional structure of biological and material specimens. Three dimensional reconstructed images of a microscopic test object will be presented; the reconstruction has a resolution on the order of 1000 A in all three dimensions. Preliminary work with biological samples will also be shown, and the experimental and numerical methods used will be discussed.

  14. Use and effectiveness of scintigraphy, sonography and angiography in circumscribed disease of the liver

    Energy Technology Data Exchange (ETDEWEB)

    Pokieser, H; Czembirek, H; Mayrhofer, H; Urbanek, A; Kahn, P; Weiss, W; Base, W [Ludwig-Boltzmann-Institut fuer Radiologisch-Physikalische Tumordiagnostik, Vienna (Austria); Vienna Univ. (Austria). 1. Medizinische Klinik; Hanuschkrankenhaus, Vienna (Austria). 1. Medizinische Abt.)

    1977-02-01

    The effectiveness of scintigraphy, sonography and angiography is compared in a material of 140 cases of circumscribed disease of the liver. Typical clinical starting points are defined as points of reference of the diagnostic techniques. Clinical diagnosis is very safe in cases of secondary blastoma and hepatocellular carcinoma of the liver. Since the great majority of these conditions cause space-occupying lesions of the liver, problems of radiologic diagnosis are confined to the smaller number of clinically ill-defined lesions. For the diagnosis of secondary blastomas and cystic processes of all kinds, scintigraphy and sonography are not improved by angiography. Solid space-occupying lesions of unknown origin, however, can only be recognized with angiography. Histology of both benign and malignant processes will be correct in more than 90% of cases.

  15. MRI, CT, and sonography in the preoperative evaluation of primary tumor extension in malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Layer, G.; Steudel, A.; Schild, H.H.; Schmitteckert, H.; Tuengerthal, S.; Schirren, J.; Kaick, G. van

    1999-01-01

    Purpose: Evaluation of the diagnostic value of the imaging modalities computed tomography (CT), magnetic resonance imaging (MRI), and thoracic sonography in the preoperative staging of malignant pleural mesothelioma. Results: The accuracy rates for CT were 85%, 98%, 83%, 73%, 71%, and 83%. MRI had an accuracy of 71%, 92%, 71%, 83%, 71%, and 96%, the thoracic ultrasound examinations of 76%, 63%, 51%, 60%, 71% and 89%. Conclusions: According to these results CT remains the method of choice in the preoperative assessment of T-stage of malignant pleural mesothelioma. MRI is of nearly the same value, but is not a must. Sonography may be supplementary method for operation planning. (orig./AJ) [de

  16. Visualization of the Origin of the Vertebral Arteries with Color Doppler Sonography

    International Nuclear Information System (INIS)

    Yoon, Seok Hwan; Lee, Won Hong; Lee, Dae Hyung

    2009-01-01

    Atherosclerotic disease at the origin of the vertebral arteries is one of the risk factors for vertebrobasilar ischemic disease. Assessment and visualization of the origin of the vertebral arteries with color doppler sonography is a non-trivial task. The aim of this study is to increase the visualization rate of the origin of the vertebral arteries with color doppler sonography. Color doppler sonography for the vertebral arteries included carotid arteries was performed to 198 patients. We first examined the vertebral artery in the upper neck in the direction of the subclavian artery to distinguish its origin more easily. If the vertebral artery origin was not visualized in natural position, the examiner pushed the transducer toward a clavicle or pushed the shoulder of patient by the other hand. The technical methods for visualization of the vertebral artery origin were classified into three grades: natural position, pushing the transducer, and pushing the shoulder of patient according to the depth (3.0 cm and shallower, deeper than 3.0 cm) of the origin. The origin of the vertebral arteries could be visualized in 97% on the right and in 92% on the left. The origin of the vertebral arteries could be visualized in 98.6%, 1.4%, and 0.0% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 81.2%, 14.6%, and 4.2% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at deeper than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 85.4%, 10.7%, and 3.9% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the left side. The origin of the vertebral arteries could be visualized in 55.7%, 30.4%, and 13.9% in natural position, pushing the transducer, and pushing the shoulder of

  17. A high resolution portable spectroscopy system

    International Nuclear Information System (INIS)

    Kulkarni, C.P.; Vaidya, P.P.; Paulson, M.; Bhatnagar, P.V.; Pande, S.S.; Padmini, S.

    2003-01-01

    Full text: This paper describes the system details of a High Resolution Portable Spectroscopy System (HRPSS) developed at Electronics Division, BARC. The system can be used for laboratory class, high-resolution nuclear spectroscopy applications. The HRPSS consists of a specially designed compact NIM bin, with built-in power supplies, accommodating a low power, high resolution MCA, and on-board embedded computer for spectrum building and communication. A NIM based spectroscopy amplifier and a HV module for detector bias are integrated (plug-in) in the bin. The system communicates with a host PC via a serial link. Along-with a laptop PC, and a portable HP-Ge detector, the HRPSS offers a laboratory class performance for portable applications

  18. False negative pericardial Focused Assessment with Sonography for Trauma examination following cardiac rupture from blunt thoracic trauma: a case report.

    Science.gov (United States)

    Baker, Laura; Almadani, Ammar; Ball, Chad G

    2015-07-15

    The Focused Assessment with Sonography for Trauma examination is an invaluable tool in the initial assessment of any injured patient. Although highly sensitive and accurate for identifying hemoperitoneum, occasional false negative results do occur in select scenarios. We present a previously unreported case of survival following blunt cardiac rupture with associated negative pericardial window due to a concurrent pericardial wall laceration. A healthy 46-year-old white woman presented to our level 1 trauma center with hemodynamic instability following a motor vehicle collision. Although her abdominal Focused Assessment with Sonography for Trauma windows were positive for fluid, her pericardial window was negative. After immediate transfer to the operating room in the setting of persistent instability, a subsequent thoracotomy identified a blunt cardiac rupture that was draining into the ipsilateral pleural space via an adjacent tear in the pericardium. The cardiac injury was controlled with digital pressure, resuscitation completed, and then repaired using standard cardiorrhaphy techniques. Following repair of her injuries (left ventricle, left atrial appendage, and liver), her postoperative course was uneventful. Evaluation of the pericardial space using Focused Assessment with Sonography for Trauma is an important component in the initial assessment of the severely injured patient. Even in cases of blunt mechanisms however, clinicians must be wary of occasional false negative pericardial ultrasound evaluations secondary to a concomitant pericardial laceration and subsequent decompression of hemorrhage from the cardiac rupture into the ipsilateral pleural space.

  19. The value of 3D-CT angiography and duplex sonography in comparison to arteriography in carotid artery stenoses

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Wesner, F.; Hoepfner, M.; Schwarzenberg, H.; Heller, M.

    1997-01-01

    To determine the value of 3D-CT angiography, duplex sonography in comparison to selective digital subtraction angiography for evaluation of carotid artery stenoses. Methods: 30 patients with 51 stenoses of carotid artery underwent 3D-CT angiography, duplex sonography and angiography. Quantification of stenosis was determined according to the NASCET study and categorized into mild (0-29%), moderate (30-69%), severe (70-99%) and occluded (100%). Results: The agreement of 3D-CT angiography with intraarterial digital subtraction angiography (DSA) was 62% (r=0.89; p [de

  20. Duplex sonography and magnetic resonance imaging in the clarification of nephrological complications after renal transplant

    International Nuclear Information System (INIS)

    Gueckel, C.; Krestin, G.P.; Wienand, P.

    1989-01-01

    A prospective study compared Duplex sonography and magnetic resonance imaging in evaluating renal transplant. Hundred and two Duplex sonographic and 24 MR examinations were performed and correlated with clinical course or biopsy. All normal renal allografts, 6 transplants with acute tubular necrosis and 2 cases of cyclosporin toxicity had normal Doppler waveforms, whereas 9 renal transplants with evidence of interstitial rejection by biopsy showed an obliteration or reversal of diastolic flow. MR imaging was less specific in identifying allograft rejection. There were false positive results in normal renal transplants, allografts with acute tubular necrosis and after rejection therapy. With regard to cost, accessibility and specificity, Duplex sonography is the method of choice for the evaluation of renal allografts. (orig.) [de

  1. High Resolution Elevation Contours

    Data.gov (United States)

    Minnesota Department of Natural Resources — This dataset contains contours generated from high resolution data sources such as LiDAR. Generally speaking this data is 2 foot or less contour interval.

  2. Extension of least squares spectral resolution algorithm to high-resolution lipidomics data

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Ying-Xu [Department of Chemistry, University of Bergen, PO Box 7803, N-5020 Bergen (Norway); Mjøs, Svein Are, E-mail: svein.mjos@kj.uib.no [Department of Chemistry, University of Bergen, PO Box 7803, N-5020 Bergen (Norway); David, Fabrice P.A. [Bioinformatics and Biostatistics Core Facility, School of Life Sciences, Ecole Polytechnique Fédérale de Lausanne (EPFL) and Swiss Institute of Bioinformatics (SIB), Lausanne (Switzerland); Schmid, Adrien W. [Proteomics Core Facility, Ecole Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne (Switzerland)

    2016-03-31

    Lipidomics, which focuses on the global study of molecular lipids in biological systems, has been driven tremendously by technical advances in mass spectrometry (MS) instrumentation, particularly high-resolution MS. This requires powerful computational tools that handle the high-throughput lipidomics data analysis. To address this issue, a novel computational tool has been developed for the analysis of high-resolution MS data, including the data pretreatment, visualization, automated identification, deconvolution and quantification of lipid species. The algorithm features the customized generation of a lipid compound library and mass spectral library, which covers the major lipid classes such as glycerolipids, glycerophospholipids and sphingolipids. Next, the algorithm performs least squares resolution of spectra and chromatograms based on the theoretical isotope distribution of molecular ions, which enables automated identification and quantification of molecular lipid species. Currently, this methodology supports analysis of both high and low resolution MS as well as liquid chromatography-MS (LC-MS) lipidomics data. The flexibility of the methodology allows it to be expanded to support more lipid classes and more data interpretation functions, making it a promising tool in lipidomic data analysis. - Highlights: • A flexible strategy for analyzing MS and LC-MS data of lipid molecules is proposed. • Isotope distribution spectra of theoretically possible compounds were generated. • High resolution MS and LC-MS data were resolved by least squares spectral resolution. • The method proposed compounds that are likely to occur in the analyzed samples. • The proposed compounds matched results from manual interpretation of fragment spectra.

  3. Extension of least squares spectral resolution algorithm to high-resolution lipidomics data

    International Nuclear Information System (INIS)

    Zeng, Ying-Xu; Mjøs, Svein Are; David, Fabrice P.A.; Schmid, Adrien W.

    2016-01-01

    Lipidomics, which focuses on the global study of molecular lipids in biological systems, has been driven tremendously by technical advances in mass spectrometry (MS) instrumentation, particularly high-resolution MS. This requires powerful computational tools that handle the high-throughput lipidomics data analysis. To address this issue, a novel computational tool has been developed for the analysis of high-resolution MS data, including the data pretreatment, visualization, automated identification, deconvolution and quantification of lipid species. The algorithm features the customized generation of a lipid compound library and mass spectral library, which covers the major lipid classes such as glycerolipids, glycerophospholipids and sphingolipids. Next, the algorithm performs least squares resolution of spectra and chromatograms based on the theoretical isotope distribution of molecular ions, which enables automated identification and quantification of molecular lipid species. Currently, this methodology supports analysis of both high and low resolution MS as well as liquid chromatography-MS (LC-MS) lipidomics data. The flexibility of the methodology allows it to be expanded to support more lipid classes and more data interpretation functions, making it a promising tool in lipidomic data analysis. - Highlights: • A flexible strategy for analyzing MS and LC-MS data of lipid molecules is proposed. • Isotope distribution spectra of theoretically possible compounds were generated. • High resolution MS and LC-MS data were resolved by least squares spectral resolution. • The method proposed compounds that are likely to occur in the analyzed samples. • The proposed compounds matched results from manual interpretation of fragment spectra.

  4. Local recurrences after conservative surgery and irradiation for breast cancer: Diagnosis with mammography and ultrasound. Mammographie und Sonographie in der Rezidivdiagnostik nach brusterhaltender Therapie des Mammakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Buchberger, W; Hamberger, L; Schoen, G [Innsbruck Univ. (Austria). Universitaetsklinik fuer Radiodiagnostik; Steixner, G; Fritsch, E [Innsbruck Univ. (Austria). Universitaetsklinik fuer Strahlentherapie

    1991-06-01

    89 patients, who underwent conservative surgery for breast cancer were followed up with mammography and real-time sonography. 78 patients underwent postoperative irradiation. Depending on the time interval between irradiation and examination various alterations in mammographic and sonographic patterns were evident. Of 14 biospy-confirmed local recurrences, 11 were diagnosed by mammography and 12 by sonography. Combined use of mammography and sonography should therefore lead to better results in the diagnosis of local recurrences and to a reduction of unnecessary biopsies. (orig./GDG).

  5. Ultra-high resolution coded wavefront sensor

    KAUST Repository

    Wang, Congli

    2017-06-08

    Wavefront sensors and more general phase retrieval methods have recently attracted a lot of attention in a host of application domains, ranging from astronomy to scientific imaging and microscopy. In this paper, we introduce a new class of sensor, the Coded Wavefront Sensor, which provides high spatio-temporal resolution using a simple masked sensor under white light illumination. Specifically, we demonstrate megapixel spatial resolution and phase accuracy better than 0.1 wavelengths at reconstruction rates of 50 Hz or more, thus opening up many new applications from high-resolution adaptive optics to real-time phase retrieval in microscopy.

  6. X-ray or sonography - at the example of the mesotheliomen

    International Nuclear Information System (INIS)

    Wimmer, B.; Grosser, G.; Kaiser, D.

    1981-01-01

    The primary method to present the mesothelioma is always the X-ray picture. The differential-diagnostical spectrum, however, is very wide. Sonography and computerized tomography can help to see the regions around the mesothelioma better. Thus, a large number of differential-diagnostical possibilities can be excluded. None of these methods, however, is able to substitute a histological definition. This is only possible by using effusion cytology, closed or open biopsy. (MG) [de

  7. Contrast-enhanced sonography for quantitative assessment of portal hypertension in patients with liver cirrhosis.

    Science.gov (United States)

    Qu, En-Ze; Zhang, Ying-Cai; Li, Zhi-Yan; Liu, Yang; Wang, Jin-Rui

    2014-11-01

    The clinical utility of contrast-enhanced sonography in portal hypertension remains unclear. We explored the feasibility of using contrast-enhanced sonography for noninvasive assessment of portal venous pressure. Twenty healthy individuals (control group; 9 men; mean age, 46.4 years) and 18 patients with portal hypertension (15 men; mean age, 46.2 years) were enrolled in this study. The portal hypertension group included patients who underwent splenectomy and pericardial blood vessel disarticulation at our hospital from October 2010 to March 2011. One week before surgery, patients with portal hypertension underwent preoperative liver contrast-enhanced sonography. Two-dimensional, Doppler, and contrast-enhanced sonographic parameters were compared between the groups. Portal venous pressure was measured intraoperatively by portal vein puncture in the portal hypertension group, and its relationship with the other parameters was analyzed. The 2-dimensional, Doppler, and contrast-enhanced sonographic parameters differed between the groups (P Portal venous pressure was inversely correlated with the area under the portal vein/hepatic artery time-intensity curve ratio (Qp/Qa), portal vein/hepatic artery strength ratio (Ip/Ia), and portal vein/hepatic artery wash-in perfusion slope ratio (βp/βa), with correlation coefficients of -0.701, -0.625, and -0.494, respectively. Measurement of the liver contrast-enhanced sonographic parameters Qp/Qa, Ip/Ia, and βp/βa could be used as a new quantitative method for noninvasively assessing portal venous pressure. © 2014 by the American Institute of Ultrasound in Medicine.

  8. Doppler sonography of diabetic feet: Quantitative analysis of blood flow volume

    International Nuclear Information System (INIS)

    Seo, Young Lan; Kim, Ho Chul; Choi, Chul Soon; Yoon, Dae Young; Han, Dae Hee; Moon, Jeung Hee; Bae, Sang Hoon

    2002-01-01

    To analyze Doppler sonographic findings of diabetic feet by estimating the quantitative blood flow volume and by analyzing waveform on Doppler. Doppler sonography was performed in thirty four patients (10 diabetic patients with foot ulceration, 14 diabetic patients without ulceration and 10 normal patients as the normal control group) to measure the flow volume of the arteries of the lower extremities (posterior and anterior tibial arteries, and distal femoral artery. Analysis of doppler waveforms was also done to evaluate the nature of the changed blood flow volume of diabetic patients, and the waveforms were classified into triphasic, biphasic-1, biphasic-2 and monophasic patterns. Flow volume of arteries in diabetic patients with foot ulceration was increased witha statistical significance when compared to that of diabetes patients without foot ulceration of that of normal control group (P<0.05). Analysis of Doppler waveform revealed that the frequency of biphasic-2 pattern was significantly higher in diabetic patients than in normal control group(p<0.05). Doppler sonography in diabetic feet showed increased flow volume and biphasic Doppler waveform, and these findings suggest neuropathy rather than ischemic changes in diabetic feet.

  9. Noninvasive Prenatal Diagnosis of Hypohidrotic Ectodermal Dysplasia by Tooth Germ Sonography.

    Science.gov (United States)

    Wünsche, S; Jüngert, J; Faschingbauer, F; Mommsen, H; Goecke, T; Schwanitz, K; Stepan, H; Schneider, H

    2015-08-01

    Hypohidrotic ectodermal dysplasia, a potentially life-threatening heritable disorder, may be recognized already in utero by characteristic features such as oligodontia and mandibular hypoplasia. As therapeutic options and prognosis depend on the time point of diagnosis, early recognition was attempted during routine prenatal ultrasound examinations. Fetuses of nine pregnant women (one triplet and eight singleton pregnancies) with family histories of hypohidrotic ectodermal dysplasia were investigated by sonography between the 20th and 24th week of gestation. In 4 male and 2 female fetuses reduced amounts of tooth germs were detected, whereas 5 fetal subjects showed the normal amount. Three-dimensional ultrasound evaluation revealed mandibular hypoplasia in 5 of the 6 fetuses with oligodontia. Molecular genetic analysis and/or clinical findings after birth confirmed the prenatal sonographic diagnosis in each subject. In subjects with a family history of hypohidrotic ectodermal dysplasia, the diagnosis of this rare condition can be established noninvasively by sonography in the second trimester of pregnancy. Early recognition of the disorder may help to prevent dangerous hyperthermic episodes in infancy and may allow timely therapeutic interventions. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Doppler sonography of diabetic feet: Quantitative analysis of blood flow volume

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Lan; Kim, Ho Chul; Choi, Chul Soon; Yoon, Dae Young; Han, Dae Hee; Moon, Jeung Hee; Bae, Sang Hoon [Hallym University College of Medicine, Seoul (Korea, Republic of)

    2002-09-15

    To analyze Doppler sonographic findings of diabetic feet by estimating the quantitative blood flow volume and by analyzing waveform on Doppler. Doppler sonography was performed in thirty four patients (10 diabetic patients with foot ulceration, 14 diabetic patients without ulceration and 10 normal patients as the normal control group) to measure the flow volume of the arteries of the lower extremities (posterior and anterior tibial arteries, and distal femoral artery. Analysis of doppler waveforms was also done to evaluate the nature of the changed blood flow volume of diabetic patients, and the waveforms were classified into triphasic, biphasic-1, biphasic-2 and monophasic patterns. Flow volume of arteries in diabetic patients with foot ulceration was increased witha statistical significance when compared to that of diabetes patients without foot ulceration of that of normal control group (P<0.05). Analysis of Doppler waveform revealed that the frequency of biphasic-2 pattern was significantly higher in diabetic patients than in normal control group(p<0.05). Doppler sonography in diabetic feet showed increased flow volume and biphasic Doppler waveform, and these findings suggest neuropathy rather than ischemic changes in diabetic feet.

  11. Dedicated training program for shoulder sonography: the results of a quality program reverberate with everyone.

    Science.gov (United States)

    Delzell, Patricia B; Boyle, Alex; Schneider, Erika

    2015-06-01

    The purpose of this study was to define and report on the effect of a comprehensive musculoskeletal sonography training program to improve accuracy (sensitivity and specificity) for the diagnosis of rotator cuff tears in relatively inexperienced operators. Before the training program was implemented, radiologists (n = 12) had a mean of 2 years (range, training shoulder sonographic results were compared to surgical reports or, in their absence, to shoulder magnetic resonance imaging or computed tomographic arthrographic results if within 2 months of the sonographic examination. A total of 82 patients were included in the pre-training group (January 2010-December 2011), and 50 patients were included in the post-training group (January 2012-June 2013). The accuracy, sensitivity, specificity, and positive and negative predictive values were determined for the presence or absence of supraspinatus and infraspinatus tendon tears. After implementation of the training program, the sensitivity of sonography for detecting full-thickness rotator cuff tears increased by 14%, and the sensitivity for detecting partial-thickness rotator cuff tears increased by 3%. Quality improvement programs and acquisition standardization along with ongoing, focused case conferences for the entire care team increased the sensitivity of shoulder sonography for diagnosing both full- and partial-thickness rotator cuff tears, independent of the years of operator experience. © 2015 by the American Institute of Ultrasound in Medicine.

  12. High resolution data acquisition

    Science.gov (United States)

    Thornton, Glenn W.; Fuller, Kenneth R.

    1993-01-01

    A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock (38) pulse train (37) and analog circuitry (44) for generating a triangular wave (46) synchronously with the pulse train (37). The triangular wave (46) has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter (18, 32) forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter (26) counts the clock pulse train (37) during the interval to form a gross event interval time. A computer (52) then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.

  13. Prenatal sonography and computed tomography for cerebral malformations of the foetus

    Energy Technology Data Exchange (ETDEWEB)

    Brinkmann, G.; Brix, F.; Weisner, D.

    1987-07-01

    In three pregnant women, sonography and amniocentesis suggested cranial abnormalities of the foetuses. In view of the far-reaching consequences of such a diagnosis, CT was carried out to confirm the diagnosis. It was possible to show the intra-uterine abnormalities and the type of malformation in considerable detail. In one case an encephalocele was demonstrated, in the two others, an anencephalic foetus was shown.

  14. Prenatal sonography and computed tomography for cerebral malformations of the foetus

    International Nuclear Information System (INIS)

    Brinkmann, G.; Brix, F.; Weisner, D.; Kiel Univ.

    1987-01-01

    In three pregnant women, sonography and amniocentesis suggested cranial abnormalities of the foetuses. In view of the far-reaching consequences of such a diagnosis, CT was carried out to confirm the diagnosis. It was possible to show the intra-uterine abnormalities and the type of malformation in considerable detail. In one case an encephalocele was demonstrated, in the two others, an anencephalic foetus was shown. (orig.) [de

  15. High resolution time integration for Sn radiation transport

    International Nuclear Information System (INIS)

    Thoreson, Greg; McClarren, Ryan G.; Chang, Jae H.

    2008-01-01

    First order, second order and high resolution time discretization schemes are implemented and studied for the S n equations. The high resolution method employs a rate of convergence better than first order, but also suppresses artificial oscillations introduced by second order schemes in hyperbolic differential equations. All three methods were compared for accuracy and convergence rates. For non-absorbing problems, both second order and high resolution converged to the same solution as the first order with better convergence rates. High resolution is more accurate than first order and matches or exceeds the second order method. (authors)

  16. Structure of high-resolution NMR spectra

    CERN Document Server

    Corio, PL

    2012-01-01

    Structure of High-Resolution NMR Spectra provides the principles, theories, and mathematical and physical concepts of high-resolution nuclear magnetic resonance spectra.The book presents the elementary theory of magnetic resonance; the quantum mechanical theory of angular momentum; the general theory of steady state spectra; and multiple quantum transitions, double resonance and spin echo experiments.Physicists, chemists, and researchers will find the book a valuable reference text.

  17. Sonography of acne vulgaris.

    Science.gov (United States)

    Wortsman, Ximena; Claveria, Pedro; Valenzuela, Fernando; Molina, Maria Teresa; Wortsman, Jacobo

    2014-01-01

    The purpose of this study was to assess the sonographic morphology of the clinical and subclinical pathology of facial acne vulgaris. We studied patients with facial acne vulgaris diagnosed by certified dermatologists, and using a standardized protocol for sonographic examinations, we sequentially described the sonographic pathomorphologic characteristics. Lesions of particular interest to the referring clinician were also analyzed separately. Additionally, acne involvement was staged clinically and sonographically (SOS-Acne) using morphologic definitions of the relevant lesions and predefined scoring systems for gradation of the severity of acne lesions. A total of 245 acne lesions in 20 consecutive patients were studied. Sonographic abnormalities consisted of pseudocysts, folliculitis, fistulas, and calcinosis. Most conditions were subclinical and mostly due to lesion extensions deep into the dermis and hypodermis (52% of pseudocysts and 68% of fistulas). The statistical concordance between acne severity scores assigned by two separate clinicians was strong (κ = 0.8020), but the corresponding sonographic scores generally showed more severe and clinically occult involvement. Facial acne vulgaris often involves deeper tissues, beyond the reach of the spatially restricted clinical examination; these subclinical conditions can be detected and defined with sonography. Additionally, acne vulgaris is amenable to sonographic scoring.

  18. High-resolution multi-slice PET

    International Nuclear Information System (INIS)

    Yasillo, N.J.; Chintu Chen; Ordonez, C.E.; Kapp, O.H.; Sosnowski, J.; Beck, R.N.

    1992-01-01

    This report evaluates the progress to test the feasibility and to initiate the design of a high resolution multi-slice PET system. The following specific areas were evaluated: detector development and testing; electronics configuration and design; mechanical design; and system simulation. The design and construction of a multiple-slice, high-resolution positron tomograph will provide substantial improvements in the accuracy and reproducibility of measurements of the distribution of activity concentrations in the brain. The range of functional brain research and our understanding of local brain function will be greatly extended when the development of this instrumentation is completed

  19. High resolution NMR spectroscopy of synthetic polymers in bulk

    International Nuclear Information System (INIS)

    Komorski, R.A.

    1986-01-01

    The contents of this book are: Overview of high-resolution NMR of solid polymers; High-resolution NMR of glassy amorphous polymers; Carbon-13 solid-state NMR of semicrystalline polymers; Conformational analysis of polymers of solid-state NMR; High-resolution NMR studies of oriented polymers; High-resolution solid-state NMR of protons in polymers; and Deuterium NMR of solid polymers. This work brings together the various approaches for high-resolution NMR studies of bulk polymers into one volume. Heavy emphasis is, of course, given to 13C NMR studies both above and below Tg. Standard high-power pulse and wide-line techniques are not covered

  20. Can sonography define the chemical composition of gall stones

    International Nuclear Information System (INIS)

    Frentzel-Beyme, B.; Faehndrich, R.; Arnan-Thiele, B.

    1983-01-01

    Eight sonographic patterns caused by gall stones are described. In an attempt to explain these different appearances, 62 stones were analysed chemically and physically. The chemical composition of the stones did not correlate with their sonographic pattern. Cholesterol stones cannot be recognised as such by sonography. The formation of an acoustic shadow depends largely on the position of the stone within the acoustic beam. It therefore follows that the examination must be done by keeping the focal plane of the transducer in proper relationship to the stone. (orig.) [de

  1. High resolution integral holography using Fourier ptychographic approach.

    Science.gov (United States)

    Li, Zhaohui; Zhang, Jianqi; Wang, Xiaorui; Liu, Delian

    2014-12-29

    An innovative approach is proposed for calculating high resolution computer generated integral holograms by using the Fourier Ptychographic (FP) algorithm. The approach initializes a high resolution complex hologram with a random guess, and then stitches together low resolution multi-view images, synthesized from the elemental images captured by integral imaging (II), to recover the high resolution hologram through an iterative retrieval with FP constrains. This paper begins with an analysis of the principle of hologram synthesis from multi-projections, followed by an accurate determination of the constrains required in the Fourier ptychographic integral-holography (FPIH). Next, the procedure of the approach is described in detail. Finally, optical reconstructions are performed and the results are demonstrated. Theoretical analysis and experiments show that our proposed approach can reconstruct 3D scenes with high resolution.

  2. Hepatic hemangiomas with peritumoral sparing of fatty infiltration in hepatic steatosis: findings on contrast-enhanced MR imaging and on sonography

    International Nuclear Information System (INIS)

    Kim, Min Jeong; Kim, Kyoung Won; Won, Hyung Jin

    2006-01-01

    We wanted to determine the frequency of peritumoral sparing of fatty infiltration (PTSF) around hepatic hemangioma in hepatic steatosis and to evaluate the finding of these tumors on dynamic contrast-enhanced MR imaging and on sonography. This study included 76 hemangiomas in 67 patients suffering with hepatic steatosis. A diagnosis of hemangioma was based on the histologic findings, hemangioma SPECT or a compatible enhancement pattern on the dynamic contrast-enhanced MR study. For chemical shifting, PTSF was defined when there wasn't any decrease in signal intensity of the liver parenchyma on the opposed-phase images as compared with the in-phase images, and this intensity appeared as a hyperintense area around the tumor. We evaluated the frequency of PTSF and we analyzed if the presence of PTSF was related to the tumor size, the rapidity of enhancement or an associated arterioportal shunt. Among those, sonographic images were available in 55 hemangiomas. We also evaluated the sonographic appearances of hemangiomas with PTSF. Of the 76 hemangiomas, PTSF was noted on the MR chemical-shift images in 57 hemangiomas (75%). There was no significant relationship between tumor size and the presence of PTSF (ρ = .578). However, this finding was more frequently found in high-flow hemangiomas than in the slow-flow ones (ρ = .0038) and it was also related to the presence of associated arterioportal shunt (ρ = .0158). Sonographically, hemangiomas with PTSF were commonly surrounded by a peritumoral low-echoic area (28/41, 68%); these tumors more frequently showed a thin high-echoic rim on sonography than did the tumors without this finding (ρ = .0055). PTSF is commonly seen in hemangiomas in hepatic steatosis patients. Hepatic hemangiomas with PTSF tend to show rapid enhancement on dynamic MR imaging and this is accompanied by arterioportal shunt. They tend to be seen as an iso-or low-echoic mass with a thin high-echoic rim on sonography, and the mass is commonly

  3. Hepatic hemangiomas with peritumoral sparing of fatty infiltration in hepatic steatosis: findings on contrast-enhanced MR imaging and on sonography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Jeong; Kim, Kyoung Won; Won, Hyung Jin [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)] (and others)

    2006-12-15

    We wanted to determine the frequency of peritumoral sparing of fatty infiltration (PTSF) around hepatic hemangioma in hepatic steatosis and to evaluate the finding of these tumors on dynamic contrast-enhanced MR imaging and on sonography. This study included 76 hemangiomas in 67 patients suffering with hepatic steatosis. A diagnosis of hemangioma was based on the histologic findings, hemangioma SPECT or a compatible enhancement pattern on the dynamic contrast-enhanced MR study. For chemical shifting, PTSF was defined when there wasn't any decrease in signal intensity of the liver parenchyma on the opposed-phase images as compared with the in-phase images, and this intensity appeared as a hyperintense area around the tumor. We evaluated the frequency of PTSF and we analyzed if the presence of PTSF was related to the tumor size, the rapidity of enhancement or an associated arterioportal shunt. Among those, sonographic images were available in 55 hemangiomas. We also evaluated the sonographic appearances of hemangiomas with PTSF. Of the 76 hemangiomas, PTSF was noted on the MR chemical-shift images in 57 hemangiomas (75%). There was no significant relationship between tumor size and the presence of PTSF ({rho} = .578). However, this finding was more frequently found in high-flow hemangiomas than in the slow-flow ones ({rho} = .0038) and it was also related to the presence of associated arterioportal shunt ({rho} = .0158). Sonographically, hemangiomas with PTSF were commonly surrounded by a peritumoral low-echoic area (28/41, 68%); these tumors more frequently showed a thin high-echoic rim on sonography than did the tumors without this finding ({rho} = .0055). PTSF is commonly seen in hemangiomas in hepatic steatosis patients. Hepatic hemangiomas with PTSF tend to show rapid enhancement on dynamic MR imaging and this is accompanied by arterioportal shunt. They tend to be seen as an iso-or low-echoic mass with a thin high-echoic rim on sonography, and the mass is

  4. High-spatial resolution and high-spectral resolution detector for use in the measurement of solar flare hard x rays

    International Nuclear Information System (INIS)

    Desai, U.D.; Orwig, L.E.

    1988-01-01

    In the areas of high spatial resolution, the evaluation of a hard X-ray detector with 65 micron spatial resolution for operation in the energy range from 30 to 400 keV is proposed. The basic detector is a thick large-area scintillator faceplate, composed of a matrix of high-density scintillating glass fibers, attached to a proximity type image intensifier tube with a resistive-anode digital readout system. Such a detector, combined with a coded-aperture mask, would be ideal for use as a modest-sized hard X-ray imaging instrument up to X-ray energies as high as several hundred keV. As an integral part of this study it was also proposed that several techniques be critically evaluated for X-ray image coding which could be used with this detector. In the area of high spectral resolution, it is proposed to evaluate two different types of detectors for use as X-ray spectrometers for solar flares: planar silicon detectors and high-purity germanium detectors (HPGe). Instruments utilizing these high-spatial-resolution detectors for hard X-ray imaging measurements from 30 to 400 keV and high-spectral-resolution detectors for measurements over a similar energy range would be ideally suited for making crucial solar flare observations during the upcoming maximum in the solar cycle

  5. High resolution photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Arko, A.J.

    1988-01-01

    Photoelectron Spectroscopy (PES) covers a very broad range of measurements, disciplines, and interests. As the next generation light source, the FEL will result in improvements over the undulator that are larger than the undulater improvements over bending magnets. The combination of high flux and high inherent resolution will result in several orders of magnitude gain in signal to noise over measurements using synchrotron-based undulators. The latter still require monochromators. Their resolution is invariably strongly energy-dependent so that in the regions of interest for many experiments (h upsilon > 100 eV) they will not have a resolving power much over 1000. In order to study some of the interesting phenomena in actinides (heavy fermions e.g.) one would need resolving powers of 10 4 to 10 5 . These values are only reachable with the FEL

  6. [Changes of renal blood flow during organ-associated foot reflexology measured by color Doppler sonography].

    Science.gov (United States)

    Sudmeier, I; Bodner, G; Egger, I; Mur, E; Ulmer, H; Herold, M

    1999-06-01

    Using colour Doppler sonography blood flow changes of the right kidney during foot reflexology were determined in a placebo-controlled, double-blind, randomised study. 32 healthy young adults (17 women, 15 men) were randomly assigned to the verum or placebo group. The verum group received foot reflexology at zones corresponding to the right kidney, the placebo group was treated on other foot zones. Before, during and after foot reflexology the blood flow of three vessels of the right kidney was measured using colour Doppler sonography. Systolic peak velocity and end diastolic peak velocity were measured in cm/s, and the resistive index, a parameter of the vascular resistance, was calculated. The resistive index in the verum group showed a highly significant decrease (p foot reflexology. There was no difference between men and women and no difference between smokers and non-smokers. Verum and placebo group significantly differed concerning alterations of the resistive index both between the measuring points before versus during foot reflexology (p = 0.002) and those during versus after foot reflexology (p = 0.031). The significant decrease of the resistive index during foot reflexology in the verum group indicates a decrease of flow resistance in renal vessels and an increase of renal blood flow. These findings support the hypothesis that organ-associated foot reflexology is effective in changing renal blood flow during therapy.

  7. Muscle sonography in six patients with hereditary inclusion body myopathy

    International Nuclear Information System (INIS)

    Adler, Ronald S.; Garolfalo, Giovanna; Paget, Stephen; Kagen, Lawrence

    2008-01-01

    To evaluate the morphological changes of muscle with sonography in six patients affected by hereditary inclusion body myopathy (HIBM). We studied a group of six Persian Jews diagnosed with HIBM. All were homozygous for the GNE mutation M712T. Ultrasonographic examinations of the quadriceps femoris and hamstring muscle groups were performed. A follow-up ultrasound examination was performed, after an interval of 3 years, in four of these patients. Muscles were assessed subjectively as to echogenicity, determined by gray-scale assessment, and loss of normal muscle morphology. Power Doppler sonography (PDS) was used to assess vascularity. A sonographic finding of central atrophy and peripheral sparing resulting in a target-like appearance was noted in the hamstring compartment of all six patients. The quadriceps compartment also showed involvement of the rectus femoris of all patients, which, in some cases, was the only muscle involved in the quadriceps. Vascularity was markedly reduced in the affected areas, with blood flow demonstrated in the peripherally spared areas. The severity of atrophy increased with disease duration. In this case series, we describe a new sonographic finding as well as document progression of HIBM disease, which has generally been described as quadriceps sparing. The myopathic target lesion, as well as isolated rectus femoris atrophy, may provide a useful adjunct to disease diagnosis. (orig.)

  8. High-resolution regional climate model evaluation using variable-resolution CESM over California

    Science.gov (United States)

    Huang, X.; Rhoades, A.; Ullrich, P. A.; Zarzycki, C. M.

    2015-12-01

    Understanding the effect of climate change at regional scales remains a topic of intensive research. Though computational constraints remain a problem, high horizontal resolution is needed to represent topographic forcing, which is a significant driver of local climate variability. Although regional climate models (RCMs) have traditionally been used at these scales, variable-resolution global climate models (VRGCMs) have recently arisen as an alternative for studying regional weather and climate allowing two-way interaction between these domains without the need for nudging. In this study, the recently developed variable-resolution option within the Community Earth System Model (CESM) is assessed for long-term regional climate modeling over California. Our variable-resolution simulations will focus on relatively high resolutions for climate assessment, namely 28km and 14km regional resolution, which are much more typical for dynamically downscaled studies. For comparison with the more widely used RCM method, the Weather Research and Forecasting (WRF) model will be used for simulations at 27km and 9km. All simulations use the AMIP (Atmospheric Model Intercomparison Project) protocols. The time period is from 1979-01-01 to 2005-12-31 (UTC), and year 1979 was discarded as spin up time. The mean climatology across California's diverse climate zones, including temperature and precipitation, is analyzed and contrasted with the Weather Research and Forcasting (WRF) model (as a traditional RCM), regional reanalysis, gridded observational datasets and uniform high-resolution CESM at 0.25 degree with the finite volume (FV) dynamical core. The results show that variable-resolution CESM is competitive in representing regional climatology on both annual and seasonal time scales. This assessment adds value to the use of VRGCMs for projecting climate change over the coming century and improve our understanding of both past and future regional climate related to fine

  9. Section on High Resolution Optical Imaging (HROI)

    Data.gov (United States)

    Federal Laboratory Consortium — The Section on High Resolution Optical Imaging (HROI) develops novel technologies for studying biological processes at unprecedented speed and resolution. Research...

  10. Validation of color Doppler sonography for evaluating relative displacement between the flexor tendon and subsynovial connective tissue.

    Science.gov (United States)

    Tat, Jimmy; Kociolek, Aaron M; Keir, Peter J

    2015-04-01

    A common pathologic finding in carpal tunnel syndrome is fibrosis and thickening of the subsynovial connective tissue. This finding suggests an etiology of excessive shear forces, with relative longitudinal displacement between the flexor tendon and adjacent subsynovial connective tissue. The purpose of this study was to validate color Doppler sonography for measurement of tendon displacement over time. Eight unmatched fresh frozen cadaver arms were used to evaluate color Doppler sonography for measurement of tendon displacement. The middle flexor digitorum superficialis tendon was moved through a physiologic excursion of 20 mm at 3 different tendon velocities (50, 100, and 150 mm/s). We found that color Doppler sonography provided accurate measurement of tendon displacement, with absolute errors of -0.05 mm (50 mm/s), -1.24 mm (100 mm/s), and -2.36 mm (150 mm/s) on average throughout the tendon excursion range. Evaluating relative displacement between the tendon and subsynovial connective tissue during finger flexion-extension movements also offered insight into the gliding mechanism of the subsynovial connective tissue. During flexion, we observed a curvilinear increase in relative displacement, with greater differential motion at the end range of displacement, likely due to the sequential stretch of the fibrils between successive layers of the subsynovial connective tissue. In extension, there was a linear return in relative displacement, suggesting a different unloading mechanism characterized by uniform relaxation of fibrils. We demonstrated the validity of color Doppler displacement for use in the evaluation of relative motion. Color Doppler sonography is useful in our understanding of the behavior of the subsynovial connective tissue during tendon excursion, which may elucidate the role of finger motion in the etiology of shear injury. © 2015 by the American Institute of Ultrasound in Medicine.

  11. Thyroid disease in the pediatric patient: emphasizing imaging with sonography

    International Nuclear Information System (INIS)

    Babcock, Diane S.

    2006-01-01

    Thyroid disease does occur in the pediatric patient, and imaging plays an important role in its evaluation. A review is presented of normal development of the thyroid gland, the technique and indications for thyroid sonography, and key imaging features of congenital thyroid disorders (ectopic or absent thyroid, infantile goiter, thyroglossal duct remnants), benign thyroid masses (follicular adenoma, degenerative nodules, colloid and thyroid cysts), malignant masses (follicular, papillary and medullary carcinoma) and diffuse thyroid disease (acute bacterial thyroiditis, Hashimoto's thyroiditis, Grave's disease). (orig.)

  12. High angular resolution at LBT

    Science.gov (United States)

    Conrad, A.; Arcidiacono, C.; Bertero, M.; Boccacci, P.; Davies, A. G.; Defrere, D.; de Kleer, K.; De Pater, I.; Hinz, P.; Hofmann, K. H.; La Camera, A.; Leisenring, J.; Kürster, M.; Rathbun, J. A.; Schertl, D.; Skemer, A.; Skrutskie, M.; Spencer, J. R.; Veillet, C.; Weigelt, G.; Woodward, C. E.

    2015-12-01

    High angular resolution from ground-based observatories stands as a key technology for advancing planetary science. In the window between the angular resolution achievable with 8-10 meter class telescopes, and the 23-to-40 meter giants of the future, LBT provides a glimpse of what the next generation of instruments providing higher angular resolution will provide. We present first ever resolved images of an Io eruption site taken from the ground, images of Io's Loki Patera taken with Fizeau imaging at the 22.8 meter LBT [Conrad, et al., AJ, 2015]. We will also present preliminary analysis of two data sets acquired during the 2015 opposition: L-band fringes at Kurdalagon and an occultation of Loki and Pele by Europa (see figure). The light curves from this occultation will yield an order of magnitude improvement in spatial resolution along the path of ingress and egress. We will conclude by providing an overview of the overall benefit of recent and future advances in angular resolution for planetary science.

  13. A method for generating high resolution satellite image time series

    Science.gov (United States)

    Guo, Tao

    2014-10-01

    There is an increasing demand for satellite remote sensing data with both high spatial and temporal resolution in many applications. But it still is a challenge to simultaneously improve spatial resolution and temporal frequency due to the technical limits of current satellite observation systems. To this end, much R&D efforts have been ongoing for years and lead to some successes roughly in two aspects, one includes super resolution, pan-sharpen etc. methods which can effectively enhance the spatial resolution and generate good visual effects, but hardly preserve spectral signatures and result in inadequate analytical value, on the other hand, time interpolation is a straight forward method to increase temporal frequency, however it increase little informative contents in fact. In this paper we presented a novel method to simulate high resolution time series data by combing low resolution time series data and a very small number of high resolution data only. Our method starts with a pair of high and low resolution data set, and then a spatial registration is done by introducing LDA model to map high and low resolution pixels correspondingly. Afterwards, temporal change information is captured through a comparison of low resolution time series data, and then projected onto the high resolution data plane and assigned to each high resolution pixel according to the predefined temporal change patterns of each type of ground objects. Finally the simulated high resolution data is generated. A preliminary experiment shows that our method can simulate a high resolution data with a reasonable accuracy. The contribution of our method is to enable timely monitoring of temporal changes through analysis of time sequence of low resolution images only, and usage of costly high resolution data can be reduces as much as possible, and it presents a highly effective way to build up an economically operational monitoring solution for agriculture, forest, land use investigation

  14. Sonography-guided hydrostatic reduction of ileocolic intussusception in children: analysis of failure and success in consecutive patients presenting timely to the hospital.

    Science.gov (United States)

    Menke, Jan; Kahl, Fritz

    2015-03-01

    In children with ileocolic intussusception sonography is increasingly being used for diagnosis, whereas fluoroscopy is frequently used for guiding non-invasive reduction. This study assessed the success rate of radiation-free sonography-guided hydrostatic reduction in children with ileocolic intussusception, using novel well-defined success rate indices. All children were evaluated who presented from 2005 to 2013 to the local university hospital with ileocolic intussusception. The patients were treated with sonography-guided hydrostatic reduction unless primary surgery was clinically indicated. The according success rate was determined by indices of Bekdash et al. They represent the ratio of persistently successful non-surgical reductions versus four different denominators, depending on including/excluding cases with primary surgery and including/excluding cases requiring bowel resection/intervention. Fifty-six consecutive patients were included (age, 3 months to 7.8 years). About 80% of the patients presented until 24 h and 20% until 48 h after the onset of symptoms. Seven patients underwent primary surgery, with bowel resection required in three cases. Hydrostatic reduction was attempted in 49 patients, being permanently successful in 41 cases (selective reduction rate 41/49 = 83.7%; crude reduction rate 41/56 = 73.2%). The remaining eight patients underwent secondary surgery, with just two patients not requiring surgical bowel resection/intervention (corrected selective reduction rate 41/43 = 95.3%). The composite reduction rate was 87.2% (successful/feasible reductions, 41/47). Radiation-free sonography-guided hydrostatic reduction has a good success rate in children with ileocolic intussusception. It may be particularly valuable in centers that are already experienced with using sonography for the diagnosis.

  15. Negative predictive value of ultrasound in predicting tumor-free margins in specimen sonography

    International Nuclear Information System (INIS)

    Naz, S.; Hafeez, S.; Hussain, Z.; Hilal, K.

    2017-01-01

    Objective: To evaluate the success of ultrasound in post-excision specimen visualization, and negative predictive value of ultrasound for estimation of tumor-free margins using histopathology as the gold standard. Study Design: Cross-sectional analytical study. Place and Duration of Study: The Aga Khan University Hospital, Karachi, Pakistan, from May 2010 till January 2013. Methodology: Sonography of all breast nodules was done before and after exicision by two female radiologists with at least five years clinical experience. All surgeries were performed by the same referring breast surgeons. All nodules were non-palpable and had histopathology as well as specimen sonography performed at AKUH. Subjects were excluded, if histopathology was not available, post-procedure sonogram not done or done in another hospital and nodules that were not seen on ultrasound. After needle localization in 47 patients using ultrasound and in 7 patients using mammogram was done, sonogram was conducted in all 54 lesions. These were then assessed by ultrasound for detection of lesion and tumor-free margins in malignant lesion. Post-excision ultrasound was performed for the evaluation of lesion whether visualized or absent with localizing needle in situ, lesion dimensions, depth measurement between the superior margin of the lesion and its edge. Results: All 54 lesions were present on post-exicison scan, out of which 28 were documented as malignant and 26 as benign. Ultrasound declared all specimens as tumor-free. On histopathology, two lesions were documented as having tumor-positive margins and were proven to be invasive lobular carcinoma. Therefore, the negative predictive value of the specimen sonography for margin detection was 26/28 (92.8%). Conclusion: Ultrasound of the excised breast tumor specimen is a simple and reliable technique for confirmation of the tumor-free margins in non-palpable breast lesions. (author)

  16. Resolution enhancement of low-quality videos using a high-resolution frame

    Science.gov (United States)

    Pham, Tuan Q.; van Vliet, Lucas J.; Schutte, Klamer

    2006-01-01

    This paper proposes an example-based Super-Resolution (SR) algorithm of compressed videos in the Discrete Cosine Transform (DCT) domain. Input to the system is a Low-Resolution (LR) compressed video together with a High-Resolution (HR) still image of similar content. Using a training set of corresponding LR-HR pairs of image patches from the HR still image, high-frequency details are transferred from the HR source to the LR video. The DCT-domain algorithm is much faster than example-based SR in spatial domain 6 because of a reduction in search dimensionality, which is a direct result of the compact and uncorrelated DCT representation. Fast searching techniques like tree-structure vector quantization 16 and coherence search1 are also key to the improved efficiency. Preliminary results on MJPEG sequence show promising result of the DCT-domain SR synthesis approach.

  17. A cloud mask methodology for high resolution remote sensing data combining information from high and medium resolution optical sensors

    Science.gov (United States)

    Sedano, Fernando; Kempeneers, Pieter; Strobl, Peter; Kucera, Jan; Vogt, Peter; Seebach, Lucia; San-Miguel-Ayanz, Jesús

    2011-09-01

    This study presents a novel cloud masking approach for high resolution remote sensing images in the context of land cover mapping. As an advantage to traditional methods, the approach does not rely on thermal bands and it is applicable to images from most high resolution earth observation remote sensing sensors. The methodology couples pixel-based seed identification and object-based region growing. The seed identification stage relies on pixel value comparison between high resolution images and cloud free composites at lower spatial resolution from almost simultaneously acquired dates. The methodology was tested taking SPOT4-HRVIR, SPOT5-HRG and IRS-LISS III as high resolution images and cloud free MODIS composites as reference images. The selected scenes included a wide range of cloud types and surface features. The resulting cloud masks were evaluated through visual comparison. They were also compared with ad-hoc independently generated cloud masks and with the automatic cloud cover assessment algorithm (ACCA). In general the results showed an agreement in detected clouds higher than 95% for clouds larger than 50 ha. The approach produced consistent results identifying and mapping clouds of different type and size over various land surfaces including natural vegetation, agriculture land, built-up areas, water bodies and snow.

  18. Thyroid disease in the pediatric patient: emphasizing imaging with sonography

    Energy Technology Data Exchange (ETDEWEB)

    Babcock, Diane S. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2006-04-15

    Thyroid disease does occur in the pediatric patient, and imaging plays an important role in its evaluation. A review is presented of normal development of the thyroid gland, the technique and indications for thyroid sonography, and key imaging features of congenital thyroid disorders (ectopic or absent thyroid, infantile goiter, thyroglossal duct remnants), benign thyroid masses (follicular adenoma, degenerative nodules, colloid and thyroid cysts), malignant masses (follicular, papillary and medullary carcinoma) and diffuse thyroid disease (acute bacterial thyroiditis, Hashimoto's thyroiditis, Grave's disease). (orig.)

  19. High-Resolution Mass Spectrometers

    Science.gov (United States)

    Marshall, Alan G.; Hendrickson, Christopher L.

    2008-07-01

    Over the past decade, mass spectrometry has been revolutionized by access to instruments of increasingly high mass-resolving power. For small molecules up to ˜400 Da (e.g., drugs, metabolites, and various natural organic mixtures ranging from foods to petroleum), it is possible to determine elemental compositions (CcHhNnOoSsPp…) of thousands of chemical components simultaneously from accurate mass measurements (the same can be done up to 1000 Da if additional information is included). At higher mass, it becomes possible to identify proteins (including posttranslational modifications) from proteolytic peptides, as well as lipids, glycoconjugates, and other biological components. At even higher mass (˜100,000 Da or higher), it is possible to characterize posttranslational modifications of intact proteins and to map the binding surfaces of large biomolecule complexes. Here we review the principles and techniques of the highest-resolution analytical mass spectrometers (time-of-flight and Fourier transform ion cyclotron resonance and orbitrap mass analyzers) and describe some representative high-resolution applications.

  20. USGS High Resolution Orthoimagery Collection - Historical - National Geospatial Data Asset (NGDA) High Resolution Orthoimagery

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — USGS high resolution orthorectified images from The National Map combine the image characteristics of an aerial photograph with the geometric qualities of a map. An...

  1. High throughput screening of ligand binding to macromolecules using high resolution powder diffraction

    Science.gov (United States)

    Von Dreele, Robert B.; D'Amico, Kevin

    2006-10-31

    A process is provided for the high throughput screening of binding of ligands to macromolecules using high resolution powder diffraction data including producing a first sample slurry of a selected polycrystalline macromolecule material and a solvent, producing a second sample slurry of a selected polycrystalline macromolecule material, one or more ligands and the solvent, obtaining a high resolution powder diffraction pattern on each of said first sample slurry and the second sample slurry, and, comparing the high resolution powder diffraction pattern of the first sample slurry and the high resolution powder diffraction pattern of the second sample slurry whereby a difference in the high resolution powder diffraction patterns of the first sample slurry and the second sample slurry provides a positive indication for the formation of a complex between the selected polycrystalline macromolecule material and at least one of the one or more ligands.

  2. Texton-based super-resolution for achieving high spatiotemporal resolution in hybrid camera system

    Science.gov (United States)

    Kamimura, Kenji; Tsumura, Norimichi; Nakaguchi, Toshiya; Miyake, Yoichi

    2010-05-01

    Many super-resolution methods have been proposed to enhance the spatial resolution of images by using iteration and multiple input images. In a previous paper, we proposed the example-based super-resolution method to enhance an image through pixel-based texton substitution to reduce the computational cost. In this method, however, we only considered the enhancement of a texture image. In this study, we modified this texton substitution method for a hybrid camera to reduce the required bandwidth of a high-resolution video camera. We applied our algorithm to pairs of high- and low-spatiotemporal-resolution videos, which were synthesized to simulate a hybrid camera. The result showed that the fine detail of the low-resolution video can be reproduced compared with bicubic interpolation and the required bandwidth could be reduced to about 1/5 in a video camera. It was also shown that the peak signal-to-noise ratios (PSNRs) of the images improved by about 6 dB in a trained frame and by 1.0-1.5 dB in a test frame, as determined by comparison with the processed image using bicubic interpolation, and the average PSNRs were higher than those obtained by the well-known Freeman’s patch-based super-resolution method. Compared with that of the Freeman’s patch-based super-resolution method, the computational time of our method was reduced to almost 1/10.

  3. Immersion Gratings for Infrared High-resolution Spectroscopy

    Science.gov (United States)

    Sarugaku, Yuki; Ikeda, Yuji; Kobayashi, Naoto; Kaji, Sayumi; Sukegawa, Takashi; Sugiyama, Shigeru; Nakagawa, Takao; Arasaki, Takayuki; Kondo, Sohei; Nakanishi, Kenshi; Yasui, Chikako; Kawakita, Hideyo

    2016-10-01

    High-resolution spectroscopy in the infrared wavelength range is essential for observations of minor isotopologues, such as HDO for water, and prebiotic organic molecules like hydrocarbons/P-bearing molecules because numerous vibrational molecular bands (including non-polar molecules) are located in this wavelength range. High spectral resolution enables us to detect weak lines without spectral line confusion. This technique has been widely used in planetary sciences, e.g., cometary coma (H2O, CO, and organic molecules), the martian atmosphere (CH4, CO2, H2O and HDO), and the upper atmosphere of gas giants (H3+ and organic molecules such as C2H6). Spectrographs with higher resolution (and higher sensitivity) still have a potential to provide a plenty of findings. However, because the size of spectrographs scales with the spectral resolution, it is difficult to realize it.Immersion grating (IG), which is a diffraction grating wherein the diffraction surface is immersed in a material with a high refractive index (n > 2), provides n times higher spectral resolution compared to a reflective grating of the same size. Because IG reduces the size of spectrograph to 1/n compared to the spectrograph with the same spectral resolution using a conventional reflective grating, it is widely acknowledged as a key optical device to realize compact spectrographs with high spectral resolution.Recently, we succeeded in fabricating a CdZnTe immersion grating with the theoretically predicted diffraction efficiency by machining process using an ultrahigh-precision five-axis processing machine developed by Canon Inc. Using the same technique, we completed a practical germanium (Ge) immersion grating with both a reflection coating on the grating surface and the an AR coating on the entrance surface. It is noteworthy that the wide wavelength range from 2 to 20 um can be covered by the two immersion gratings.In this paper, we present the performances and the applications of the immersion

  4. High resolution tomographic instrument development

    International Nuclear Information System (INIS)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational

  5. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  6. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  7. Blunt splenic trauma: Can contrast enhanced sonography be used for the screening of delayed pseudoaneurysms?

    Energy Technology Data Exchange (ETDEWEB)

    Poletti, Pierre-Alexandre, E-mail: Pierre-Alexandre.Poletti@hcuge.ch [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Becker, Christoph D.; Arditi, Daniel; Terraz, Sylvain [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Buchs, Nicolas [Department of Surgery, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Shanmuganathan, Kathirkamanathan [Department of Diagnostic Radiology and Nuclear Medicine, 22 S. Greene Street, Baltimore, MD 21201 (United States); Platon, Alexandra [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland)

    2013-11-01

    Purpose: To assess the value of contrast-enhanced sonography (CES) for the detection of delayed post-traumatic splenic pseudo-aneurysms, usually considered an indication for angiographic embolization. Methods: Sixty-three consecutive hemodynamically stable trauma patients in whom admission CT displayed a splenic injury of grade II or higher (AAST classification), without evidence of vascular involvement, were included in the study. CES of the spleen using a second generation contrast agent was systematically performed within 48–72 h after admission, for the detection of a pooling of contrast media suggestive of pseudoaneurysm. Within 6 h after contrast-enhanced sonography, all patients underwent an abdominal CT for control purposes. CES results were compared to CT findings, which were considered the reference standard. This study received approval from the institutional ethical board. Results: CES showed a blush of contrast consistent with a pseudoaneurysm in 6 of the 63 patients. All were confirmed at subsequent control CT. Pooling of contrast was found at CT in 2 patients in whom contrast-enhanced sonography was negative. There was no false positive CES examination for the suspicion of pseudoaneurysms. When compared to CT, the sensitivity, specificity, positive and negative predictive values of CES to suggest a pseudoaneurysms, were 75% (6/8), 100% (55/55), 100% (6/6), and 96% (55/57), respectively. Conclusion: Our data suggest that CES may be useful for the screening of delayed traumatic splenic pseudoaneurysms: if a negative CES does not absolutely rule out a pseudoaneurysm, a positive CES warrants an angiography, without need of control CT.

  8. Blunt splenic trauma: Can contrast enhanced sonography be used for the screening of delayed pseudoaneurysms?

    International Nuclear Information System (INIS)

    Poletti, Pierre-Alexandre; Becker, Christoph D.; Arditi, Daniel; Terraz, Sylvain; Buchs, Nicolas; Shanmuganathan, Kathirkamanathan; Platon, Alexandra

    2013-01-01

    Purpose: To assess the value of contrast-enhanced sonography (CES) for the detection of delayed post-traumatic splenic pseudo-aneurysms, usually considered an indication for angiographic embolization. Methods: Sixty-three consecutive hemodynamically stable trauma patients in whom admission CT displayed a splenic injury of grade II or higher (AAST classification), without evidence of vascular involvement, were included in the study. CES of the spleen using a second generation contrast agent was systematically performed within 48–72 h after admission, for the detection of a pooling of contrast media suggestive of pseudoaneurysm. Within 6 h after contrast-enhanced sonography, all patients underwent an abdominal CT for control purposes. CES results were compared to CT findings, which were considered the reference standard. This study received approval from the institutional ethical board. Results: CES showed a blush of contrast consistent with a pseudoaneurysm in 6 of the 63 patients. All were confirmed at subsequent control CT. Pooling of contrast was found at CT in 2 patients in whom contrast-enhanced sonography was negative. There was no false positive CES examination for the suspicion of pseudoaneurysms. When compared to CT, the sensitivity, specificity, positive and negative predictive values of CES to suggest a pseudoaneurysms, were 75% (6/8), 100% (55/55), 100% (6/6), and 96% (55/57), respectively. Conclusion: Our data suggest that CES may be useful for the screening of delayed traumatic splenic pseudoaneurysms: if a negative CES does not absolutely rule out a pseudoaneurysm, a positive CES warrants an angiography, without need of control CT

  9. Ancillary lung parenchymal findings at spiral CT scanning in pulmonary embolism. Relationship to chest sonography

    International Nuclear Information System (INIS)

    Reissig, Angelika; Heyne, Jens-Peter; Kroegel, Claus

    2004-01-01

    Introduction/objective: The aim of the study was to compare findings of transthoracic sonography (TS) and of spiral computed tomography (sCT) in patients with suspected pulmonary embolism (PE). Methods and patients: Peripheral parenchymal and pleural findings of TS and sCT were compared in 62 patients (25 females, 37 males; mean age 62.2 years) with suspected PE. Results: In 39 patients PE was established, of whose pleura-based lesions could be detected by TS in 30 patients and by sCT in 31 patients. Whilst in three of the patients parenchymal lesions were exclusively detected by sonography, no peripheral abnormalities could be discovered with either technique in five patients. Among the nine patients lacking peripheral abnormalities on sonography, four revealed peripheral lesions in sCT. In 23 patients without PE, peripheral consolidations at CT were detected in six patients whereas two showed lesions on TS. With respect to the appearance, pleura-based wedge-shaped consolidations were the main parenchymal alterations (82.4% at TS, 66.1% at sCT) as compared with non-wedge-shaped consolidations (17.6% at TS, 33.9% at sCT). Peripheral lesions were located preferentially within the lower lobes. In addition, both localised and basal pleural effusion associated with PE could be demonstrated in 58.9% at TS and in 23.1% by sCT. Discussions and conclusion: The study shows that in PE parenchymal and pleural changes are detectable by TS and sCT. If parenchymal findings are present at sCT, peripheral PE should be considered, even in the absence of directly visible emboli

  10. Ancillary lung parenchymal findings at spiral CT scanning in pulmonary embolism. Relationship to chest sonography

    Energy Technology Data Exchange (ETDEWEB)

    Reissig, Angelika E-mail: angelika.reissig@med.uni-jena.de; Heyne, Jens-Peter; Kroegel, Claus

    2004-03-01

    Introduction/objective: The aim of the study was to compare findings of transthoracic sonography (TS) and of spiral computed tomography (sCT) in patients with suspected pulmonary embolism (PE). Methods and patients: Peripheral parenchymal and pleural findings of TS and sCT were compared in 62 patients (25 females, 37 males; mean age 62.2 years) with suspected PE. Results: In 39 patients PE was established, of whose pleura-based lesions could be detected by TS in 30 patients and by sCT in 31 patients. Whilst in three of the patients parenchymal lesions were exclusively detected by sonography, no peripheral abnormalities could be discovered with either technique in five patients. Among the nine patients lacking peripheral abnormalities on sonography, four revealed peripheral lesions in sCT. In 23 patients without PE, peripheral consolidations at CT were detected in six patients whereas two showed lesions on TS. With respect to the appearance, pleura-based wedge-shaped consolidations were the main parenchymal alterations (82.4% at TS, 66.1% at sCT) as compared with non-wedge-shaped consolidations (17.6% at TS, 33.9% at sCT). Peripheral lesions were located preferentially within the lower lobes. In addition, both localised and basal pleural effusion associated with PE could be demonstrated in 58.9% at TS and in 23.1% by sCT. Discussions and conclusion: The study shows that in PE parenchymal and pleural changes are detectable by TS and sCT. If parenchymal findings are present at sCT, peripheral PE should be considered, even in the absence of directly visible emboli.

  11. Transcranial sonography for diagnosis of Parkinson's disease

    Directory of Open Access Journals (Sweden)

    Maaser Peter

    2010-01-01

    Full Text Available Abstract Background In idiopathic Parkinson's disease (IPD transcranial sonography (TCS represents an alternative diagnostic method to verify clinical diagnosis. Although the phenomenon of an increased echogenicity of the Substantia nigra (SN is well known this method is still not widly used in the diagnostic workup. Until now reliability of this method is still a matter of debate, partly because data only existed from a few laboratories using the same ultrasound machine. Therefore our study was conducted to test the reliability of this method by using a different ultrasound device and examining a large population of control and IPD subjects by two examiners to calculate interobserver reliability. Method In this study echogenicity of SN was examined in 199 IPD patients and 201 control subjects. All individuals underwent a neurological assessment including Perdue pegboard test and Webster gait test. Using a Sonos 5500 ultrasound device area of SN was measured, echogenicity of raphe, red nuclei, thalamus, caudate and lenticular nuclei, width of third and lateral ventricle were documented. Results We found a highly characteristic enlargement of the SN echogenic signal in IPD. The cut-off value for the SN area was established using a ROC curve with a sensitivity of 95% corresponding to an area of SN of 0.2 cm2 and was found to be equivalent to the cut-off values of other studies using different ultrasound devices. Conclusions Our study shows that TCS is a reliable and highly sensitive tool for differentiation of IPD patients from individuals without CNS disorders.

  12. High resolution Neutron and Synchrotron Powder Diffraction

    International Nuclear Information System (INIS)

    Hewat, A.W.

    1986-01-01

    The use of high-resolution powder diffraction has grown rapidly in the past years, with the development of Rietveld (1967) methods of data analysis and new high-resolution diffractometers and multidetectors. The number of publications in this area has increased from a handful per year until 1973 to 150 per year in 1984, with a ten-year total of over 1000. These papers cover a wide area of solid state-chemistry, physics and materials science, and have been grouped under 20 subject headings, ranging from catalysts to zeolites, and from battery electrode materials to pre-stressed superconducting wires. In 1985 two new high-resolution diffractometers are being commissioned, one at the SNS laboratory near Oxford, and one at the ILL in Grenoble. In different ways these machines represent perhaps the ultimate that can be achieved with neutrons and will permit refinement of complex structures with about 250 parameters and unit cell volumes of about 2500 Angstrom/sp3/. The new European Synchotron Facility will complement the Grenoble neutron diffractometers, and extend the role of high-resolution powder diffraction to the direct solution of crystal structures, pioneered in Sweden

  13. High resolution (transformers.

    Science.gov (United States)

    Garcia-Souto, Jose A; Lamela-Rivera, Horacio

    2006-10-16

    A novel fiber-optic interferometric sensor is presented for vibrations measurements and analysis. In this approach, it is shown applied to the vibrations of electrical structures within power transformers. A main feature of the sensor is that an unambiguous optical phase measurement is performed using the direct detection of the interferometer output, without external modulation, for a more compact and stable implementation. High resolution of the interferometric measurement is obtained with this technique (transformers are also highlighted.

  14. High-resolution wavefront control of high-power laser systems

    International Nuclear Information System (INIS)

    Brase, J.; Brown, C.; Carrano, C.; Kartz, M.; Olivier, S.; Pennington, D.; Silva, D.

    1999-01-01

    Nearly every new large-scale laser system application at LLNL has requirements for beam control which exceed the current level of available technology. For applications such as inertial confinement fusion, laser isotope separation, laser machining, and laser the ability to transport significant power to a target while maintaining good beam quality is critical. There are many ways that laser wavefront quality can be degraded. Thermal effects due to the interaction of high-power laser or pump light with the internal optical components or with the ambient gas are common causes of wavefront degradation. For many years, adaptive optics based on thing deformable glass mirrors with piezoelectric or electrostrictive actuators have be used to remove the low-order wavefront errors from high-power laser systems. These adaptive optics systems have successfully improved laser beam quality, but have also generally revealed additional high-spatial-frequency errors, both because the low-order errors have been reduced and because deformable mirrors have often introduced some high-spatial-frequency components due to manufacturing errors. Many current and emerging laser applications fall into the high-resolution category where there is an increased need for the correction of high spatial frequency aberrations which requires correctors with thousands of degrees of freedom. The largest Deformable Mirrors currently available have less than one thousand degrees of freedom at a cost of approximately $1M. A deformable mirror capable of meeting these high spatial resolution requirements would be cost prohibitive. Therefore a new approach using a different wavefront control technology is needed. One new wavefront control approach is the use of liquid-crystal (LC) spatial light modulator (SLM) technology for the controlling the phase of linearly polarized light. Current LC SLM technology provides high-spatial-resolution wavefront control, with hundreds of thousands of degrees of freedom, more

  15. High resolution optical DNA mapping

    Science.gov (United States)

    Baday, Murat

    Many types of diseases including cancer and autism are associated with copy-number variations in the genome. Most of these variations could not be identified with existing sequencing and optical DNA mapping methods. We have developed Multi-color Super-resolution technique, with potential for high throughput and low cost, which can allow us to recognize more of these variations. Our technique has made 10--fold improvement in the resolution of optical DNA mapping. Using a 180 kb BAC clone as a model system, we resolved dense patterns from 108 fluorescent labels of two different colors representing two different sequence-motifs. Overall, a detailed DNA map with 100 bp resolution was achieved, which has the potential to reveal detailed information about genetic variance and to facilitate medical diagnosis of genetic disease.

  16. Mammary blood supply in various diseases as evidenced by color Doppler sonography

    International Nuclear Information System (INIS)

    Kharchenko, V.P.; Rozhkova, N.I.; Zubovskij, G.A.; Medvedeva, N.A.

    1993-01-01

    Color dopplerosonography, traditional sonography, and mammography without contrast staining, as well as physical and pathomorphologic methods were used in examinations of the mammary glands of 76 women aged 18 to 65. Characteristic features of the blood supply to the gland were detected, and differential diagnostic criteria defined on the basis of these findings, to simplify differentiation between malignant and benign nodular formations and the diffuse changes in the mamma

  17. High-Resolution Electronics: Spontaneous Patterning of High-Resolution Electronics via Parallel Vacuum Ultraviolet (Adv. Mater. 31/2016).

    Science.gov (United States)

    Liu, Xuying; Kanehara, Masayuki; Liu, Chuan; Sakamoto, Kenji; Yasuda, Takeshi; Takeya, Jun; Minari, Takeo

    2016-08-01

    On page 6568, T. Minari and co-workers describe spontaneous patterning based on the parallel vacuum ultraviolet (PVUV) technique, enabling the homogeneous integration of complex, high-resolution electronic circuits, even on large-scale, flexible, transparent substrates. Irradiation of PVUV to the hydrophobic polymer surface precisely renders the selected surface into highly wettable regions with sharply defined boundaries, which spontaneously guides a metal nanoparticle ink into a series of circuit lines and gaps with the widths down to a resolution of 1 μm. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. High resolution UV spectroscopy and laser-focused nanofabrication

    NARCIS (Netherlands)

    Myszkiewicz, G.

    2005-01-01

    This thesis combines two at first glance different techniques: High Resolution Laser Induced Fluorescence Spectroscopy (LIF) of small aromatic molecules and Laser Focusing of atoms for Nanofabrication. The thesis starts with the introduction to the high resolution LIF technique of small aromatic

  19. High-resolution spectrometer at PEP

    International Nuclear Information System (INIS)

    Weiss, J.M.; HRS Collaboration.

    1982-01-01

    A description is presented of the High Resolution Spectrometer experiment (PEP-12) now running at PEP. The advanced capabilities of the detector are demonstrated with first physics results expected in the coming months

  20. Clinical study of color Doppler sonography in Graves' disease blood flow changes after thyroid arteries embolization

    International Nuclear Information System (INIS)

    Zhuang Wenquan; Li Weiduo; Yang Jianyong; Chen Wei; Huang Yonghui; Guo Wenbo; Li Jiaping

    2003-01-01

    Objective: To study the color doppler image characteristics of thyroid arteries pre- and post-interventional procedure and to assess the clinical efficacy in Gnaves' disease. Methods: 11 from 31 patients diagnosed as Graves' disease undertaken thyroid arteries embolization, were analyzed. Color Doppler sonography was applied to monitor the pre-and post- procedure thyroid size and diameters of thyroid arteries. Power Doppler was used to detect the Vmax, Vmin, RI and blood flow. Results: After thyroid arteries embolization, the size and vascularity of thyroids were reduced. The thyroid arteries showed shrinkage and stoppage blood flow at the embolized site. The changes of RI, blood parameters of Vmax, Vmin and diameters of the thyroid arteries pre- and post-procedure turned out to be statistically significant for clinical restriction. Conclusion: The color Doppler sonography plays an important role for preoperative diagnosis and predicting the prognosis

  1. High-resolution structure of the native histone octamer

    International Nuclear Information System (INIS)

    Wood, Christopher M.; Nicholson, James M.; Lambert, Stanley J.; Chantalat, Laurent; Reynolds, Colin D.; Baldwin, John P.

    2005-01-01

    The high-resolution (1.90 Å) model of the native histone octamer allows structural comparisons to be made with the nucleosome-core particle, along with an identification of a likely core-histone binding site. Crystals of native histone octamers (H2A–H2B)–(H4–H3)–(H3′–H4′)–(H2B′–H2A′) from chick erythrocytes in 2 M KCl, 1.35 M potassium phosphate pH 6.9 diffract X-rays to 1.90 Å resolution, yielding a structure with an R work value of 18.7% and an R free of 22.2%. The crystal space group is P6 5 , the asymmetric unit of which contains one complete octamer. This high-resolution model of the histone-core octamer allows further insight into intermolecular interactions, including water molecules, that dock the histone dimers to the tetramer in the nucleosome-core particle and have relevance to nucleosome remodelling. The three key areas analysed are the H2A′–H3–H4 molecular cluster (also H2A–H3′–H4′), the H4–H2B′ interaction (also H4′–H2B) and the H2A′–H4 β-sheet interaction (also H2A–H4′). The latter of these three regions is important to nucleosome remodelling by RNA polymerase II, as it is shown to be a likely core-histone binding site, and its disruption creates an instability in the nucleosome-core particle. A majority of the water molecules in the high-resolution octamer have positions that correlate to similar positions in the high-resolution nucleosome-core particle structure, suggesting that the high-resolution octamer model can be used for comparative studies with the high-resolution nucleosome-core particle

  2. Requirements on high resolution detectors

    Energy Technology Data Exchange (ETDEWEB)

    Koch, A. [European Synchrotron Radiation Facility, Grenoble (France)

    1997-02-01

    For a number of microtomography applications X-ray detectors with a spatial resolution of 1 {mu}m are required. This high spatial resolution will influence and degrade other parameters of secondary importance like detective quantum efficiency (DQE), dynamic range, linearity and frame rate. This note summarizes the most important arguments, for and against those detector systems which could be considered. This article discusses the mutual dependencies between the various figures which characterize a detector, and tries to give some ideas on how to proceed in order to improve present technology.

  3. High-resolution clean-sc

    NARCIS (Netherlands)

    Sijtsma, P.; Snellen, M.

    2016-01-01

    In this paper a high-resolution extension of CLEAN-SC is proposed: HR-CLEAN-SC. Where CLEAN-SC uses peak sources in “dirty maps” to define so-called source components, HR-CLEAN-SC takes advantage of the fact that source components can likewise be derived from points at some distance from the peak,

  4. MR imaging-guided sonography followed by fine-needle aspiration cytology in occult carcinoma of the breast

    NARCIS (Netherlands)

    A.I.M. Obdeijn (Inge-Marie); Brouwers-Kuyper, E.M.; M.M.A. Tilanus-Linthorst (Madeleine); T. Wiggers (Theo); M. Oudkerk (Matthijs)

    2000-01-01

    markdownabstractOBJECTIVE. In patients with axillary metastases as clinical evidence of possible occult breast cancer, a combined approach of MR imaging, sonography, and aspiration biopsy cytology was evaluated. SUBJECTS AND METHODS. Thirty-one women with metastatic adenocarcinoma in their

  5. Planning for shallow high resolution seismic surveys

    CSIR Research Space (South Africa)

    Fourie, CJS

    2008-11-01

    Full Text Available of the input wave. This information can be used in conjunction with this spreadsheet to aid the geophysicist in designing shallow high resolution seismic surveys to achieve maximum resolution and penetration. This Excel spreadsheet is available free from...

  6. Fatty liver: prospective comparative study with sonography and CT

    International Nuclear Information System (INIS)

    Kim, Sung Jin; Kim, Y. M.; Kim, W. S.; Choi, B. I.; Lee, J. S.; Han, C. K.; Kim, C. W.

    1990-01-01

    To identify the reasonable criteria in detection of the degree of Fatty liver, we prospectively evaluated sonograms and CT scans in 33 Patients With bright liver on sonography. On sonograms, we analyzed the echogenicity of the liver, acoustic attenuation, and visualization of the portal vein and the diaphragm, Each criterion was scored from 0 to 2. CT criterion for fatty liver was assessed by the attenuation difference between the liver and the spleen on nonocontrast CT scans, The average sonographic grade for CT Grade I was 1.3, Grade II was 2.1,and Grade III was 2.8. The accurate detection rate of each sonographic grade was as follows, Grade

  7. Gamma-ray spectrometer system with high efficiency and high resolution

    International Nuclear Information System (INIS)

    Moss, C.E.; Bernard, W.; Dowdy, E.J.; Garcia, C.; Lucas, M.C.; Pratt, J.C.

    1983-01-01

    Our gamma-ray spectrometer system, designed for field use, offers high efficiency and high resolution for safeguards applications. The system consists of three 40% high-purity germanium detectors and a LeCroy 3500 data acquisition system that calculates a composite spectrum for the three detectors. The LeCroy 3500 mainframe can be operated remotely from the detector array with control exercised through modems and the telephone system. System performance with a mixed source of 125 Sb, 154 Eu, and 155 Eu confirms the expected efficiency of 120% with the overall resolution showing little degradation over that of the worst detector

  8. High-frequency ultrasound probe sonography staging for colorectal neoplasia with superficial morphology: its utility and impact on patient management.

    Science.gov (United States)

    Urban, Ondrej; Kliment, Martin; Fojtik, Petr; Falt, Premysl; Orhalmi, Julius; Vitek, Petr; Holeczy, Pavol

    2011-10-01

    This prospective study aimed to evaluate the impact of high-frequency ultrasound probe sonography (HFUPS) staging on the management of patients with superficial colorectal neoplasia (SCN) as determined by the endoscopic characteristics of lesions. Consecutive patients referred for endoscopic treatment of nonpedunculated SCN were enrolled in this study. A lesion was considered high risk if a depressed area or invasive pit pattern was present. The gold standard for final staging included histology from endoscopic or surgical resection. The impact on treatment was defined as any modification of the therapeutic algorithm based on the result of the HFUPS examination compared with that based on endoscopy alone. In this study, 48 lesions in 48 patients were evaluated. Of these, 28 (58%) were considered high risk, and the remaining 20 (42%) were regarded as low risk. A total of seven lesions (15%) that could not be examined with HFUPS and another non-neoplastic lesion were excluded from final analysis. For the remaining 40 lesions, the overall accuracy of the HFUPS examination to predict the correct T-stage was 90% (95% confidence interval [CI], 77-96%). The HFUPS examination had a positive impact on the treatment of 0 low-risk and 11 high-risk (42%) lesions. The impact of HFUPS on the treatment of SCN depends on their endoscopic characteristics. It is negligible for low-risk SCNs, and these lesions can be treated on the basis of their endoscopic appearance alone. Nevertheless, compared with endoscopy alone, HFUPS changed the subsequent therapeutic approach in a positive way for up to 42% of high-risk lesions, including those with a depressed component and an invasive pit pattern. These endoscopic features can therefore be recommended as the entry criteria for an HFUPS examination.

  9. High resolution metric imaging payload

    Science.gov (United States)

    Delclaud, Y.

    2017-11-01

    Alcatel Space Industries has become Europe's leader in the field of high and very high resolution optical payloads, in the frame work of earth observation system able to provide military government with metric images from space. This leadership allowed ALCATEL to propose for the export market, within a French collaboration frame, a complete space based system for metric observation.

  10. High-resolution X-ray diffraction studies of multilayers

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Hornstrup, Allan; Schnopper, H. W.

    1988-01-01

    High-resolution X-ray diffraction studies of the perfection of state-of-the-art multilayers are presented. Data were obtained using a triple-axis perfect-crystal X-ray diffractometer. Measurements reveal large-scale figure errors in the substrate. A high-resolution triple-axis set up is required...

  11. Isotope specific resolution recovery image reconstruction in high resolution PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kotasidis, Fotis A. [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva, Switzerland and Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, M20 3LJ, Manchester (United Kingdom); Angelis, Georgios I. [Faculty of Health Sciences, Brain and Mind Research Institute, University of Sydney, NSW 2006, Sydney (Australia); Anton-Rodriguez, Jose; Matthews, Julian C. [Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, Manchester M20 3LJ (United Kingdom); Reader, Andrew J. [Montreal Neurological Institute, McGill University, Montreal QC H3A 2B4, Canada and Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King' s College London, St. Thomas’ Hospital, London SE1 7EH (United Kingdom); Zaidi, Habib [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva (Switzerland); Geneva Neuroscience Centre, Geneva University, CH-1205 Geneva (Switzerland); Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, PO Box 30 001, Groningen 9700 RB (Netherlands)

    2014-05-15

    Purpose: Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measurements. As such, non-optimal PSF models that do not correspond to those needed for the data to be reconstructed are used within resolution modeling (RM) image reconstruction, usually underestimating the true PSF owing to the difference in positron range. In high resolution brain and preclinical imaging, this effect is of particular importance since the PSFs become more positron range limited and isotope-specific PSFs can help maximize the performance benefit from using resolution recovery image reconstruction algorithms. Methods: In this work, the authors used a printing technique to simultaneously measure multiple point sources on the High Resolution Research Tomograph (HRRT), and the authors demonstrated the feasibility of deriving isotope-dependent system matrices from fluorine-18 and carbon-11 point sources. Furthermore, the authors evaluated the impact of incorporating them within RM image reconstruction, using carbon-11 phantom and clinical datasets on the HRRT. Results: The results obtained using these two isotopes illustrate that even small differences in positron range can result in different PSF maps, leading to further improvements in contrast recovery when used in image reconstruction. The difference is more pronounced in the centre of the field-of-view where the full width at half maximum (FWHM) from the positron range has a larger contribution to the overall FWHM compared to the edge where the parallax error dominates the overall FWHM. Conclusions: Based on the proposed methodology, measured isotope-specific and spatially variant PSFs can be reliably derived and used for improved spatial resolution and variance performance in resolution

  12. Isotope specific resolution recovery image reconstruction in high resolution PET imaging

    International Nuclear Information System (INIS)

    Kotasidis, Fotis A.; Angelis, Georgios I.; Anton-Rodriguez, Jose; Matthews, Julian C.; Reader, Andrew J.; Zaidi, Habib

    2014-01-01

    Purpose: Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measurements. As such, non-optimal PSF models that do not correspond to those needed for the data to be reconstructed are used within resolution modeling (RM) image reconstruction, usually underestimating the true PSF owing to the difference in positron range. In high resolution brain and preclinical imaging, this effect is of particular importance since the PSFs become more positron range limited and isotope-specific PSFs can help maximize the performance benefit from using resolution recovery image reconstruction algorithms. Methods: In this work, the authors used a printing technique to simultaneously measure multiple point sources on the High Resolution Research Tomograph (HRRT), and the authors demonstrated the feasibility of deriving isotope-dependent system matrices from fluorine-18 and carbon-11 point sources. Furthermore, the authors evaluated the impact of incorporating them within RM image reconstruction, using carbon-11 phantom and clinical datasets on the HRRT. Results: The results obtained using these two isotopes illustrate that even small differences in positron range can result in different PSF maps, leading to further improvements in contrast recovery when used in image reconstruction. The difference is more pronounced in the centre of the field-of-view where the full width at half maximum (FWHM) from the positron range has a larger contribution to the overall FWHM compared to the edge where the parallax error dominates the overall FWHM. Conclusions: Based on the proposed methodology, measured isotope-specific and spatially variant PSFs can be reliably derived and used for improved spatial resolution and variance performance in resolution

  13. Isotope specific resolution recovery image reconstruction in high resolution PET imaging.

    Science.gov (United States)

    Kotasidis, Fotis A; Angelis, Georgios I; Anton-Rodriguez, Jose; Matthews, Julian C; Reader, Andrew J; Zaidi, Habib

    2014-05-01

    Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measurements. As such, non-optimal PSF models that do not correspond to those needed for the data to be reconstructed are used within resolution modeling (RM) image reconstruction, usually underestimating the true PSF owing to the difference in positron range. In high resolution brain and preclinical imaging, this effect is of particular importance since the PSFs become more positron range limited and isotope-specific PSFs can help maximize the performance benefit from using resolution recovery image reconstruction algorithms. In this work, the authors used a printing technique to simultaneously measure multiple point sources on the High Resolution Research Tomograph (HRRT), and the authors demonstrated the feasibility of deriving isotope-dependent system matrices from fluorine-18 and carbon-11 point sources. Furthermore, the authors evaluated the impact of incorporating them within RM image reconstruction, using carbon-11 phantom and clinical datasets on the HRRT. The results obtained using these two isotopes illustrate that even small differences in positron range can result in different PSF maps, leading to further improvements in contrast recovery when used in image reconstruction. The difference is more pronounced in the centre of the field-of-view where the full width at half maximum (FWHM) from the positron range has a larger contribution to the overall FWHM compared to the edge where the parallax error dominates the overall FWHM. Based on the proposed methodology, measured isotope-specific and spatially variant PSFs can be reliably derived and used for improved spatial resolution and variance performance in resolution recovery image reconstruction. The

  14. Scalable Algorithms for Large High-Resolution Terrain Data

    DEFF Research Database (Denmark)

    Mølhave, Thomas; Agarwal, Pankaj K.; Arge, Lars Allan

    2010-01-01

    In this paper we demonstrate that the technology required to perform typical GIS computations on very large high-resolution terrain models has matured enough to be ready for use by practitioners. We also demonstrate the impact that high-resolution data has on common problems. To our knowledge, so...

  15. High resolution NMR imaging using a high field yokeless permanent magnet.

    Science.gov (United States)

    Kose, Katsumi; Haishi, Tomoyuki

    2011-01-01

    We measured the homogeneity and stability of the magnetic field of a high field (about 1.04 tesla) yokeless permanent magnet with 40-mm gap for high resolution nuclear magnetic resonance (NMR) imaging. Homogeneity was evaluated using a 3-dimensional (3D) lattice phantom and 3D spin-echo imaging sequences. In the central sphere (20-mm diameter), peak-to-peak magnetic field inhomogeneity was about 60 ppm, and the root-mean-square was 8 ppm. We measured room temperature, magnet temperature, and NMR frequency of the magnet simultaneously every minute for about 68 hours with and without the thermal insulator of the magnet. A simple mathematical model described the magnet's thermal property. Based on magnet performance, we performed high resolution (up to [20 µm](2)) imaging with internal NMR lock sequences of several biological samples. Our results demonstrated the usefulness of the high field small yokeless permanent magnet for high resolution NMR imaging.

  16. High resolution NMR imaging using a high field yokeless permanent magnet

    International Nuclear Information System (INIS)

    Kose, Katsumi; Haishi, Tomoyuki

    2011-01-01

    We measured the homogeneity and stability of the magnetic field of a high field (about 1.04 tesla) yokeless permanent magnet with 40-mm gap for high resolution nuclear magnetic resonance (NMR) imaging. Homogeneity was evaluated using a 3-dimensional (3D) lattice phantom and 3D spin-echo imaging sequences. In the central sphere (20-mm diameter), peak-to-peak magnetic field inhomogeneity was about 60 ppm, and the root-mean-square was 8 ppm. We measured room temperature, magnet temperature, and NMR frequency of the magnet simultaneously every minute for about 68 hours with and without the thermal insulator of the magnet. A simple mathematical model described the magnet's thermal property. Based on magnet performance, we performed high resolution (up to [20 μm] 2 ) imaging with internal NMR lock sequences of several biological samples. Our results demonstrated the usefulness of the high field small yokeless permanent magnet for high resolution NMR imaging. (author)

  17. Progress in high-resolution x-ray holographic microscopy

    International Nuclear Information System (INIS)

    Jacobsen, C.; Kirz, J.; Howells, M.; McQuaid, K.; Rothman, S.; Feder, R.; Sayre, D.

    1987-07-01

    Among the various types of x-ray microscopes that have been demonstrated, the holographic microscope has had the largest gap between promise and performance. The difficulties of fabricating x-ray optical elements have led some to view holography as the most attractive method for obtaining the ultimate in high resolution x-ray micrographs; however, we know of no investigations prior to 1987 that clearly demonstrated submicron resolution in reconstructed images. Previous efforts suffered from problems such as limited resolution and dynamic range in the recording media, low coherent x-ray flux, and aberrations and diffraction limits in visible light reconstruction. We have addressed the recording limitations through the use of an undulator x-ray source and high-resolution photoresist recording media. For improved results in the readout and reconstruction steps, we have employed metal shadowing and transmission electron microscopy, along with numerical reconstruction techniques. We believe that this approach will allow holography to emerge as a practical method of high-resolution x-ray microscopy. 30 refs., 4 figs

  18. Progress in high-resolution x-ray holographic microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, C.; Kirz, J.; Howells, M.; McQuaid, K.; Rothman, S.; Feder, R.; Sayre, D.

    1987-07-01

    Among the various types of x-ray microscopes that have been demonstrated, the holographic microscope has had the largest gap between promise and performance. The difficulties of fabricating x-ray optical elements have led some to view holography as the most attractive method for obtaining the ultimate in high resolution x-ray micrographs; however, we know of no investigations prior to 1987 that clearly demonstrated submicron resolution in reconstructed images. Previous efforts suffered from problems such as limited resolution and dynamic range in the recording media, low coherent x-ray flux, and aberrations and diffraction limits in visible light reconstruction. We have addressed the recording limitations through the use of an undulator x-ray source and high-resolution photoresist recording media. For improved results in the readout and reconstruction steps, we have employed metal shadowing and transmission electron microscopy, along with numerical reconstruction techniques. We believe that this approach will allow holography to emerge as a practical method of high-resolution x-ray microscopy. 30 refs., 4 figs.

  19. High-resolution spectroscopy of gases for industrial applications

    DEFF Research Database (Denmark)

    Fateev, Alexander; Clausen, Sønnik

    High-resolution spectroscopy of gases is a powerful technique which has various fundamental and practical applications: in situ simultaneous measurements of gas temperature and gas composition, radiative transfer modeling, validation of existing and developing of new databases and etc. Existing...... databases (e.g. HITRAN, HITEMP or CDSD) can normally be used for absorption spectra calculations at limited temperature/pressure ranges. Therefore experimental measurements of absorption/transmission spectra gases (e.g. CO2, H2O or SO2) at high-resolution and elevated temperatures are essential both...... for analysis of complex experimental data and further development of the databases. High-temperature gas cell facilities available at DTU Chemical Engineering are presented and described. The gas cells and high-resolution spectrometers allow us to perform high-quality reference measurements of gases relevant...

  20. Towards high-resolution positron emission tomography for small volumes

    International Nuclear Information System (INIS)

    McKee, B.T.A.

    1982-01-01

    Some arguments are made regarding the medical usefulness of high spatial resolution in positron imaging, even if limited to small imaged volumes. Then the intrinsic limitations to spatial resolution in positron imaging are discussed. The project to build a small-volume, high resolution animal research prototype (SHARP) positron imaging system is described. The components of the system, particularly the detectors, are presented and brief mention is made of data acquisition and image reconstruction methods. Finally, some preliminary imaging results are presented; a pair of isolated point sources and 18 F in the bones of a rabbit. Although the detector system is not fully completed, these first results indicate that the goals of high sensitivity and high resolution (4 mm) have been realized. (Auth.)

  1. High-resolution X-ray crystal structure of bovine H-protein using the high-pressure cryocooling method

    International Nuclear Information System (INIS)

    Higashiura, Akifumi; Ohta, Kazunori; Masaki, Mika; Sato, Masaru; Inaka, Koji; Tanaka, Hiroaki; Nakagawa, Atsushi

    2013-01-01

    Using the high-pressure cryocooling method, the high-resolution X-ray crystal structure of bovine H-protein was determined at 0.86 Å resolution. This is the first ultra-high-resolution structure obtained from a high-pressure cryocooled crystal. Recently, many technical improvements in macromolecular X-ray crystallography have increased the number of structures deposited in the Protein Data Bank and improved the resolution limit of protein structures. Almost all high-resolution structures have been determined using a synchrotron radiation source in conjunction with cryocooling techniques, which are required in order to minimize radiation damage. However, optimization of cryoprotectant conditions is a time-consuming and difficult step. To overcome this problem, the high-pressure cryocooling method was developed (Kim et al., 2005 ▶) and successfully applied to many protein-structure analyses. In this report, using the high-pressure cryocooling method, the X-ray crystal structure of bovine H-protein was determined at 0.86 Å resolution. Structural comparisons between high- and ambient-pressure cryocooled crystals at ultra-high resolution illustrate the versatility of this technique. This is the first ultra-high-resolution X-ray structure obtained using the high-pressure cryocooling method

  2. High resolution drift chambers

    International Nuclear Information System (INIS)

    Va'vra, J.

    1985-07-01

    High precision drift chambers capable of achieving less than or equal to 50 μm resolutions are discussed. In particular, we compare so called cool and hot gases, various charge collection geometries, several timing techniques and we also discuss some systematic problems. We also present what we would consider an ''ultimate'' design of the vertex chamber. 50 refs., 36 figs., 6 tabs

  3. Comparative assessment of renal Tc-99m DMSA scan and renal sonography findings in complication of urinary tract infections

    International Nuclear Information System (INIS)

    Alavi, M.; Rasekhi, A.

    2002-01-01

    Urinary tract infection is a common disease in childhood specially in female. In this study 50 patients with established diagnosis of urinary tract infection were evaluated by both renal scan with Tc-99m DMSA and renal sonography. The study revealed that most urinary tract infections are in children, female sex between 5-9 years of age. Therefore the most important complications (renal scarring) are also common in this age-sex distribution. Occurrence of renal scars increase with increasing the number of recurrent infections. Vesicoureteral reflux is one of the most important, common risk factors for renal scarring. Renal Tc-99m Dmsa scan is more sensitive than renal sonography in detecting the renal scars

  4. High resolution neutron spectroscopy for helium isotopes

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; Klages, H.O.; Schmalz, G.; Haesner, B.H.; Kecskemeti, J.; Schwarz, P.; Wilczynski, J.

    1992-01-01

    A high resolution fast neutron time-of-flight spectrometer is described, neutron time-of-flight spectra are taken using a specially designed TDC in connection to an on-line computer. The high time-of-flight resolution of 5 ps/m enabled the study of the total cross section of 4 He for neutrons near the 3/2 + resonance in the 5 He nucleus. The resonance parameters were determined by a single level Breit-Winger fit to the data. (orig.)

  5. A high-resolution regional reanalysis for Europe

    Science.gov (United States)

    Ohlwein, C.

    2015-12-01

    Reanalyses gain more and more importance as a source of meteorological information for many purposes and applications. Several global reanalyses projects (e.g., ERA, MERRA, CSFR, JMA9) produce and verify these data sets to provide time series as long as possible combined with a high data quality. Due to a spatial resolution down to 50-70km and 3-hourly temporal output, they are not suitable for small scale problems (e.g., regional climate assessment, meso-scale NWP verification, input for subsequent models such as river runoff simulations). The implementation of regional reanalyses based on a limited area model along with a data assimilation scheme is able to generate reanalysis data sets with high spatio-temporal resolution. Within the Hans-Ertel-Centre for Weather Research (HErZ), the climate monitoring branch concentrates efforts on the assessment and analysis of regional climate in Germany and Europe. In joint cooperation with DWD (German Meteorological Service), a high-resolution reanalysis system based on the COSMO model has been developed. The regional reanalysis for Europe matches the domain of the CORDEX EURO-11 specifications, albeit at a higher spatial resolution, i.e., 0.055° (6km) instead of 0.11° (12km) and comprises the assimilation of observational data using the existing nudging scheme of COSMO complemented by a special soil moisture analysis with boundary conditions provided by ERA-Interim data. The reanalysis data set covers the past 20 years. Extensive evaluation of the reanalysis is performed using independent observations with special emphasis on precipitation and high-impact weather situations indicating a better representation of small scale variability. Further, the evaluation shows an added value of the regional reanalysis with respect to the forcing ERA Interim reanalysis and compared to a pure high-resolution dynamical downscaling approach without data assimilation.

  6. Standard sonography and arthrosonography in the study of rotator cuff tears

    International Nuclear Information System (INIS)

    El-Dalati, Ghassan; Martone, Enrico; Caffarri, Sabrina; Fusaro, Michele; Pozzi Mucelli, Roberto; Castellarin, Gianluca; Ricci, Matteo; Vecchini, Eugenio

    2005-01-01

    Purpose. The aim of this study was to evaluate the sensitivity of ultrasonography, integrating standard ultrasound and arthrosonography after injecting a saline solution into the glenohumeral cavity in cases of suspected rotator cuff tears. Materials and methods. We respectively examinated 40 patients awaiting shoulder arthroscopy for suspected or diagnosed tears of the rotator cuff. A radiologist, unaware of the pre-operative diagnosis, performed an ultrasound scan on all the patients before and after the injection of saline solution into the glenohumeral cavity. The parameters considered were presence or absence of a rotator cuff injury; type of injury according to Snyder and its extent along the longitudinal and transverse planes; presence or absence of effusion into the articular cavity; subacromial/subdeltoid bursal distension. All the patients underwent arthroscopy either the same day of the day after the ultrasound examination. Results. Standard sonography showed 26 complete rotator cuff tears (type C according to Snyder), 2 partial tears (type B according to Snyder) and 12 intact rotator cuffs. Arthrosonography detected 31 complete rotator cuff tears (type C according to Snyder), 1 partial tear (type B according to Snyder) and 8 intact rotator cuffs. Arthroscopy identified 32 complete rotator cuff tears (type C according to Snyder), 1 partial tear (type B according to Snyder) and 8 intact rotator cuffs. Analysis of the results shows that, taking arthroscopy as the gold standard, the sensitivity of normal sonography is 81.2%, whereas that of arthosonography is 96.8% (p [it

  7. The value of computerized tomography and sonography in different types of pancreatitis, judged on the basis of a diagnosis previously confirmed by retrograde endoscopic cholangiopancreaticography and the pancreomycin-secretin test

    International Nuclear Information System (INIS)

    Sewing, G.

    1985-01-01

    The blind study described here pointed to a diagnostic superiority of computered tomography, the results of which in chronic pancreatitis were judged to be better than those of sonography, chiefly because of its high sensitivity in the detection of calcified deposits in the pancreas. The values determined, in particular those relating to the specifity of the methods used, were lower than the data given by other authors. From the findings revealed here there was, however, sufficient evidence to confirm that both computered tomography and sonography certainly have their merits as non-invasive methods of morphological examination in the diagnosis of pancreatitis. They should therefore be used, preferably in combined form, prior to any other diagnostic measures that may be more hazardous to the patient. (MBC) [de

  8. Automated data processing of high-resolution mass spectra

    DEFF Research Database (Denmark)

    Hansen, Michael Adsetts Edberg; Smedsgaard, Jørn

    of the massive amounts of data. We present an automated data processing method to quantitatively compare large numbers of spectra from the analysis of complex mixtures, exploiting the full quality of high-resolution mass spectra. By projecting all detected ions - within defined intervals on both the time...... infusion of crude extracts into the source taking advantage of the high sensitivity, high mass resolution and accuracy and the limited fragmentation. Unfortunately, there has not been a comparable development in the data processing techniques to fully exploit gain in high resolution and accuracy...... infusion analyses of crude extract to find the relationship between species from several species terverticillate Penicillium, and also that the ions responsible for the segregation can be identified. Furthermore the process can automate the process of detecting unique species and unique metabolites....

  9. Achieving sensitive, high-resolution laser spectroscopy at CRIS

    Energy Technology Data Exchange (ETDEWEB)

    Groote, R. P. de [Instituut voor Kern- en Stralingsfysica, KU Leuven (Belgium); Lynch, K. M., E-mail: kara.marie.lynch@cern.ch [EP Department, CERN, ISOLDE (Switzerland); Wilkins, S. G. [The University of Manchester, School of Physics and Astronomy (United Kingdom); Collaboration: the CRIS collaboration

    2017-11-15

    The Collinear Resonance Ionization Spectroscopy (CRIS) experiment, located at the ISOLDE facility, has recently performed high-resolution laser spectroscopy, with linewidths down to 20 MHz. In this article, we present the modifications to the beam line and the newly-installed laser systems that have made sensitive, high-resolution measurements possible. Highlights of recent experimental campaigns are presented.

  10. An atlas of high-resolution IRAS maps on nearby galaxies

    Science.gov (United States)

    Rice, Walter

    1993-01-01

    An atlas of far-infrared IRAS maps with near 1 arcmin angular resolution of 30 optically large galaxies is presented. The high-resolution IRAS maps were produced with the Maximum Correlation Method (MCM) image construction and enhancement technique developed at IPAC. The MCM technique, which recovers the spatial information contained in the overlapping detector data samples of the IRAS all-sky survey scans, is outlined and tests to verify the structural reliability and photometric integrity of the high-resolution maps are presented. The infrared structure revealed in individual galaxies is discussed. The atlas complements the IRAS Nearby Galaxy High-Resolution Image Atlas, the high-resolution galaxy images encoded in FITS format, which is provided to the astronomical community as an IPAC product.

  11. Development of high speed integrated circuit for very high resolution timing measurements

    International Nuclear Information System (INIS)

    Mester, Christian

    2009-10-01

    A multi-channel high-precision low-power time-to-digital converter application specific integrated circuit for high energy physics applications has been designed and implemented in a 130 nm CMOS process. To reach a target resolution of 24.4 ps, a novel delay element has been conceived. This nominal resolution has been experimentally verified with a prototype, with a minimum resolution of 19 ps. To further improve the resolution, a new interpolation scheme has been described. The ASIC has been designed to use a reference clock with the LHC bunch crossing frequency of 40 MHz and generate all required timing signals internally, to ease to use within the framework of an LHC upgrade. Special care has been taken to minimise the power consumption. (orig.)

  12. Development of high speed integrated circuit for very high resolution timing measurements

    Energy Technology Data Exchange (ETDEWEB)

    Mester, Christian

    2009-10-15

    A multi-channel high-precision low-power time-to-digital converter application specific integrated circuit for high energy physics applications has been designed and implemented in a 130 nm CMOS process. To reach a target resolution of 24.4 ps, a novel delay element has been conceived. This nominal resolution has been experimentally verified with a prototype, with a minimum resolution of 19 ps. To further improve the resolution, a new interpolation scheme has been described. The ASIC has been designed to use a reference clock with the LHC bunch crossing frequency of 40 MHz and generate all required timing signals internally, to ease to use within the framework of an LHC upgrade. Special care has been taken to minimise the power consumption. (orig.)

  13. High-resolution MRI in detecting subareolar breast abscess.

    Science.gov (United States)

    Fu, Peifen; Kurihara, Yasuyuki; Kanemaki, Yoshihide; Okamoto, Kyoko; Nakajima, Yasuo; Fukuda, Mamoru; Maeda, Ichiro

    2007-06-01

    Because subareolar breast abscess has a high recurrence rate, a more effective imaging technique is needed to comprehensively visualize the lesions and guide surgery. We performed a high-resolution MRI technique using a microscopy coil to reveal the characteristics and extent of subareolar breast abscess. High-resolution MRI has potential diagnostic value in subareolar breast abscess. This technique can be used to guide surgery with the aim of reducing the recurrence rate.

  14. Recent applications of gas chromatography with high-resolution mass spectrometry.

    Science.gov (United States)

    Špánik, Ivan; Machyňáková, Andrea

    2018-01-01

    Gas chromatography coupled to high-resolution mass spectrometry is a powerful analytical method that combines excellent separation power of gas chromatography with improved identification based on an accurate mass measurement. These features designate gas chromatography with high-resolution mass spectrometry as the first choice for identification and structure elucidation of unknown volatile and semi-volatile organic compounds. Gas chromatography with high-resolution mass spectrometry quantitative analyses was previously focused on the determination of dioxins and related compounds using magnetic sector type analyzers, a standing requirement of many international standards. The introduction of a quadrupole high-resolution time-of-flight mass analyzer broadened interest in this method and novel applications were developed, especially for multi-target screening purposes. This review is focused on the development and the most interesting applications of gas chromatography coupled to high-resolution mass spectrometry towards analysis of environmental matrices, biological fluids, and food safety since 2010. The main attention is paid to various approaches and applications of gas chromatography coupled to high-resolution mass spectrometry for non-target screening to identify contaminants and to characterize the chemical composition of environmental, food, and biological samples. The most interesting quantitative applications, where a significant contribution of gas chromatography with high-resolution mass spectrometry over the currently used methods is expected, will be discussed as well. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Multi-resolution voxel phantom modeling: a high-resolution eye model for computational dosimetry.

    Science.gov (United States)

    Caracappa, Peter F; Rhodes, Ashley; Fiedler, Derek

    2014-09-21

    Voxel models of the human body are commonly used for simulating radiation dose with a Monte Carlo radiation transport code. Due to memory limitations, the voxel resolution of these computational phantoms is typically too large to accurately represent the dimensions of small features such as the eye. Recently reduced recommended dose limits to the lens of the eye, which is a radiosensitive tissue with a significant concern for cataract formation, has lent increased importance to understanding the dose to this tissue. A high-resolution eye model is constructed using physiological data for the dimensions of radiosensitive tissues, and combined with an existing set of whole-body models to form a multi-resolution voxel phantom, which is used with the MCNPX code to calculate radiation dose from various exposure types. This phantom provides an accurate representation of the radiation transport through the structures of the eye. Two alternate methods of including a high-resolution eye model within an existing whole-body model are developed. The accuracy and performance of each method is compared against existing computational phantoms.

  16. High-resolution intravital microscopy.

    Directory of Open Access Journals (Sweden)

    Volker Andresen

    Full Text Available Cellular communication constitutes a fundamental mechanism of life, for instance by permitting transfer of information through synapses in the nervous system and by leading to activation of cells during the course of immune responses. Monitoring cell-cell interactions within living adult organisms is crucial in order to draw conclusions on their behavior with respect to the fate of cells, tissues and organs. Until now, there is no technology available that enables dynamic imaging deep within the tissue of living adult organisms at sub-cellular resolution, i.e. detection at the level of few protein molecules. Here we present a novel approach called multi-beam striped-illumination which applies for the first time the principle and advantages of structured-illumination, spatial modulation of the excitation pattern, to laser-scanning-microscopy. We use this approach in two-photon-microscopy--the most adequate optical deep-tissue imaging-technique. As compared to standard two-photon-microscopy, it achieves significant contrast enhancement and up to 3-fold improved axial resolution (optical sectioning while photobleaching, photodamage and acquisition speed are similar. Its imaging depth is comparable to multifocal two-photon-microscopy and only slightly less than in standard single-beam two-photon-microscopy. Precisely, our studies within mouse lymph nodes demonstrated 216% improved axial and 23% improved lateral resolutions at a depth of 80 µm below the surface. Thus, we are for the first time able to visualize the dynamic interactions between B cells and immune complex deposits on follicular dendritic cells within germinal centers (GCs of live mice. These interactions play a decisive role in the process of clonal selection, leading to affinity maturation of the humoral immune response. This novel high-resolution intravital microscopy method has a huge potential for numerous applications in neurosciences, immunology, cancer research and

  17. High-Resolution Intravital Microscopy

    Science.gov (United States)

    Andresen, Volker; Pollok, Karolin; Rinnenthal, Jan-Leo; Oehme, Laura; Günther, Robert; Spiecker, Heinrich; Radbruch, Helena; Gerhard, Jenny; Sporbert, Anje; Cseresnyes, Zoltan; Hauser, Anja E.; Niesner, Raluca

    2012-01-01

    Cellular communication constitutes a fundamental mechanism of life, for instance by permitting transfer of information through synapses in the nervous system and by leading to activation of cells during the course of immune responses. Monitoring cell-cell interactions within living adult organisms is crucial in order to draw conclusions on their behavior with respect to the fate of cells, tissues and organs. Until now, there is no technology available that enables dynamic imaging deep within the tissue of living adult organisms at sub-cellular resolution, i.e. detection at the level of few protein molecules. Here we present a novel approach called multi-beam striped-illumination which applies for the first time the principle and advantages of structured-illumination, spatial modulation of the excitation pattern, to laser-scanning-microscopy. We use this approach in two-photon-microscopy - the most adequate optical deep-tissue imaging-technique. As compared to standard two-photon-microscopy, it achieves significant contrast enhancement and up to 3-fold improved axial resolution (optical sectioning) while photobleaching, photodamage and acquisition speed are similar. Its imaging depth is comparable to multifocal two-photon-microscopy and only slightly less than in standard single-beam two-photon-microscopy. Precisely, our studies within mouse lymph nodes demonstrated 216% improved axial and 23% improved lateral resolutions at a depth of 80 µm below the surface. Thus, we are for the first time able to visualize the dynamic interactions between B cells and immune complex deposits on follicular dendritic cells within germinal centers (GCs) of live mice. These interactions play a decisive role in the process of clonal selection, leading to affinity maturation of the humoral immune response. This novel high-resolution intravital microscopy method has a huge potential for numerous applications in neurosciences, immunology, cancer research and developmental biology

  18. Fusiform-shaped nodules along the internal carotid artery demonstrated by follow-up sonography within the dissected neck area in patients with oral cancer

    International Nuclear Information System (INIS)

    Hayashi, Takafumi; Katsura, Kouji; Taira, Shuhzou; Shingaki, Susumu; Hoshina, Hideyuki

    2004-01-01

    In order to distinguish benign from malignant nodules within the dissected neck area in patients with oral cancer during the follow-up period, we retrospectively evaluated the frequency and characteristic findings of fusiform-shaped nodules along the internal carotid artery observed by follow-up sonography. From 1997 to 2003, 52 patients with oral cancer, who underwent radical neck dissections, were enrolled in this study. The study cohort consisted of 33 males and 19 females ranging in age from 29 to 84 years (mean, 62.0 years). After neck dissection, every patient was examined repeatedly with sonography during the follow-up period at an interval of one month. CT and/or MRI were performed when clinically required. Any patient with recurrent neck mass was excluded from this study. In the 52 patients, fusiform-shaped nodules were observed in 10 patients (19%) by the follow-up sonography. The nodules were homogenously hypoechoic and the margin was well-demarcated except for the upper end. A hyperechoic core was clearly observed in every nodule, which showed a fatty density on post-contrast CT. On post-contrast MRI, the nodules enhanced markedly and the core showed hypointensity on fat saturated images. In conclusion, it was suggested that the fusiform-shaped nodules observed by follow-up sonography within the dissected neck area might be the superior cervical ganglion of sympathetic trunk. However, further studies are needed to disclose the true character of the nodules. (author)

  19. 3-D sonography for diagnosis of disk dislocation of the temporomandibular joint compared with MRI.

    Science.gov (United States)

    Landes, Constantin A; Goral, Wojciech A; Sader, Robert; Mack, Martin G

    2006-05-01

    This study determines the value of three-dimensional (3-D) sonography for the assessment of disk dislocation of the temporomandibular joint (TMJ). Sixty-eight patients (i.e.,136 TMJ) with clinical dysfunction were examined by 272 sonographic 3-D scans. An 8- to 12.5-MHz transducer, angulated by step-motor, was used after picking a volume box on 2-D scan; magnetic resonance imaging followed immediately. Every TMJ was scrutinized in closed- and open-mouth position for normal or dislocated disk position. Fifty-three patients had complete data sets, i.e., 106 TMJ, 212 examinations. Sonographic examination took 5 min, with 74% specificity (62% closed-mouth; 85% open-mouth); sensitivity 53% (62/43%); accuracy 70% (62/77%); positive predictive value 49% (57/41%); and negative predictive value 77% (67/86%). This study encourages more research on the diagnostic capacity of 3-D TMJ sonography, with the advantage of multidimensional joint visualization. Although fair in specificity and negative predictive value, sensitivity and accuracy may ameliorate with future higher-sound frequency, real-time 3-D viewing and automated image analysis.

  20. Hyper-resolution urban flood modeling using high-resolution radar precipitation and LiDAR data

    Science.gov (United States)

    Noh, S. J.; Lee, S.; Lee, J.; Seo, D. J.

    2016-12-01

    Floods occur most frequently among all natural hazards, often causing widespread economic damage and loss of human lives. In particular, urban flooding is becoming increasingly costly and difficult to manage with a greater concentration of population and assets in urban centers. Despite of known benefits for accurate representation of small scale features and flow interaction among different flow domains, which have significant impact on flood propagation, high-resolution modeling has not been fully utilized due to expensive computation and various uncertainties from model structure, input and parameters. In this study, we assess the potential of hyper-resolution hydrologic-hydraulic modeling using high-resolution radar precipitation and LiDAR data for improved urban flood prediction and hazard mapping. We describe a hyper-resolution 1D-2D coupled urban flood model for pipe and surface flows and evaluate the accuracy of the street-level inundation information produced. For detailed geometric representation of urban areas and for computational efficiency, we use 1 m-resolution topographical data, processed from LiDAR measurements, in conjunction with adaptive mesh refinement. For street-level simulation in large urban areas at grid sizes of 1 to 10 m, a hybrid parallel computing scheme using MPI and openMP is also implemented in a high-performance computing system. The modeling approach developed is applied for the Johnson Creek Catchment ( 40 km2), which makes up the Arlington Urban Hydroinformatics Testbed. In addition, discussion will be given on availability of hyper-resolution simulation archive for improved real-time flood mapping.

  1. Analysis of the impact of spatial resolution on land/water classifications using high-resolution aerial imagery

    Science.gov (United States)

    Enwright, Nicholas M.; Jones, William R.; Garber, Adrienne L.; Keller, Matthew J.

    2014-01-01

    Long-term monitoring efforts often use remote sensing to track trends in habitat or landscape conditions over time. To most appropriately compare observations over time, long-term monitoring efforts strive for consistency in methods. Thus, advances and changes in technology over time can present a challenge. For instance, modern camera technology has led to an increasing availability of very high-resolution imagery (i.e. submetre and metre) and a shift from analogue to digital photography. While numerous studies have shown that image resolution can impact the accuracy of classifications, most of these studies have focused on the impacts of comparing spatial resolution changes greater than 2 m. Thus, a knowledge gap exists on the impacts of minor changes in spatial resolution (i.e. submetre to about 1.5 m) in very high-resolution aerial imagery (i.e. 2 m resolution or less). This study compared the impact of spatial resolution on land/water classifications of an area dominated by coastal marsh vegetation in Louisiana, USA, using 1:12,000 scale colour-infrared analogue aerial photography (AAP) scanned at four different dot-per-inch resolutions simulating ground sample distances (GSDs) of 0.33, 0.54, 1, and 2 m. Analysis of the impact of spatial resolution on land/water classifications was conducted by exploring various spatial aspects of the classifications including density of waterbodies and frequency distributions in waterbody sizes. This study found that a small-magnitude change (1–1.5 m) in spatial resolution had little to no impact on the amount of water classified (i.e. percentage mapped was less than 1.5%), but had a significant impact on the mapping of very small waterbodies (i.e. waterbodies ≤ 250 m2). These findings should interest those using temporal image classifications derived from very high-resolution aerial photography as a component of long-term monitoring programs.

  2. Image Quality in High-resolution and High-cadence Solar Imaging

    Science.gov (United States)

    Denker, C.; Dineva, E.; Balthasar, H.; Verma, M.; Kuckein, C.; Diercke, A.; González Manrique, S. J.

    2018-03-01

    Broad-band imaging and even imaging with a moderate bandpass (about 1 nm) provides a photon-rich environment, where frame selection (lucky imaging) becomes a helpful tool in image restoration, allowing us to perform a cost-benefit analysis on how to design observing sequences for imaging with high spatial resolution in combination with real-time correction provided by an adaptive optics (AO) system. This study presents high-cadence (160 Hz) G-band and blue continuum image sequences obtained with the High-resolution Fast Imager (HiFI) at the 1.5-meter GREGOR solar telescope, where the speckle-masking technique is used to restore images with nearly diffraction-limited resolution. The HiFI employs two synchronized large-format and high-cadence sCMOS detectors. The median filter gradient similarity (MFGS) image-quality metric is applied, among others, to AO-corrected image sequences of a pore and a small sunspot observed on 2017 June 4 and 5. A small region of interest, which was selected for fast-imaging performance, covered these contrast-rich features and their neighborhood, which were part of Active Region NOAA 12661. Modifications of the MFGS algorithm uncover the field- and structure-dependency of this image-quality metric. However, MFGS still remains a good choice for determining image quality without a priori knowledge, which is an important characteristic when classifying the huge number of high-resolution images contained in data archives. In addition, this investigation demonstrates that a fast cadence and millisecond exposure times are still insufficient to reach the coherence time of daytime seeing. Nonetheless, the analysis shows that data acquisition rates exceeding 50 Hz are required to capture a substantial fraction of the best seeing moments, significantly boosting the performance of post-facto image restoration.

  3. Smartphone microendoscopy for high resolution fluorescence imaging

    Directory of Open Access Journals (Sweden)

    Xiangqian Hong

    2016-09-01

    Full Text Available High resolution optical endoscopes are increasingly used in diagnosis of various medical conditions of internal organs, such as the cervix and gastrointestinal (GI tracts, but they are too expensive for use in resource-poor settings. On the other hand, smartphones with high resolution cameras and Internet access have become more affordable, enabling them to diffuse into most rural areas and developing countries in the past decade. In this paper, we describe a smartphone microendoscope that can take fluorescence images with a spatial resolution of 3.1 μm. Images collected from ex vivo, in vitro and in vivo samples using the device are also presented. The compact and cost-effective smartphone microendoscope may be envisaged as a powerful tool for detecting pre-cancerous lesions of internal organs in low and middle-income countries (LMICs.

  4. High resolution mid-infrared spectroscopy based on frequency upconversion

    DEFF Research Database (Denmark)

    Dam, Jeppe Seidelin; Hu, Qi; Tidemand-Lichtenberg, Peter

    2013-01-01

    signals can be analyzed. The obtainable frequency resolution is usually in the nm range where sub nm resolution is preferred in many applications, like gas spectroscopy. In this work we demonstrate how to obtain sub nm resolution when using upconversion. In the presented realization one object point...... high resolution spectral performance by observing emission from hot water vapor in a butane gas burner....

  5. Climate change and high-resolution whole-building numerical modelling

    NARCIS (Netherlands)

    Blocken, B.J.E.; Briggen, P.M.; Schellen, H.L.; Hensen, J.L.M.

    2010-01-01

    This paper briefly discusses the need of high-resolution whole-building numerical modelling in the context of climate change. High-resolution whole-building numerical modelling can be used for detailed analysis of the potential consequences of climate change on buildings and to evaluate remedial

  6. Sonography and MRI of latissimus dorsi strain injury in four elite athletes

    International Nuclear Information System (INIS)

    Pedret, Carles; Balius, Ramon; Idoate, Fernando

    2011-01-01

    The objective of this study was to describe the MR and sonographic findings in latissimus dorsi (LD) muscle strain in athletes, and to review the most common injuries described in the literature, most of which are humeral avulsions. Four injuries and two reinjuries of the myotendinous junction of the LD were followed from the day of injury until the return to play. Sonography (US) and MR imaging were performed in each case to confirm the diagnosis and to monitor the healing process. All cases had acute and isolated pain in the back of the shoulder while performing an eccentric maneuver of the arm and the shoulder. US and MR images demonstrated that injuries were located in the middle and cranial portion of the latissimus dorsi surrounding the myotendinous junction. After rehabilitation, all players played at high level again. Isolated lesions of LD are very rare. They can be demonstrated by US and MR images. (orig.)

  7. Sonography and MRI of latissimus dorsi strain injury in four elite athletes

    Energy Technology Data Exchange (ETDEWEB)

    Pedret, Carles [Unitat Medicina Esportiva Consorci Sanitari del Garraf, Barcelona (Spain); Centre Diagnostic per Imatge de Tarragona, Tarragona (Spain); Balius, Ramon [Generalitat of Catalonia, Sports Catalan Council, Catalonia (Spain); Idoate, Fernando [Clinica San Miguel, Department of Radiology, Pamplona (Spain)

    2011-05-15

    The objective of this study was to describe the MR and sonographic findings in latissimus dorsi (LD) muscle strain in athletes, and to review the most common injuries described in the literature, most of which are humeral avulsions. Four injuries and two reinjuries of the myotendinous junction of the LD were followed from the day of injury until the return to play. Sonography (US) and MR imaging were performed in each case to confirm the diagnosis and to monitor the healing process. All cases had acute and isolated pain in the back of the shoulder while performing an eccentric maneuver of the arm and the shoulder. US and MR images demonstrated that injuries were located in the middle and cranial portion of the latissimus dorsi surrounding the myotendinous junction. After rehabilitation, all players played at high level again. Isolated lesions of LD are very rare. They can be demonstrated by US and MR images. (orig.)

  8. New approach to 3-D, high sensitivity, high mass resolution space plasma composition measurements

    International Nuclear Information System (INIS)

    McComas, D.J.; Nordholt, J.E.

    1990-01-01

    This paper describes a new type of 3-D space plasma composition analyzer. The design combines high sensitivity, high mass resolution measurements with somewhat lower mass resolution but even higher sensitivity measurements in a single compact and robust design. While the lower resolution plasma measurements are achieved using conventional straight-through time-of-flight mass spectrometry, the high mass resolution measurements are made by timing ions reflected in a linear electric field (LEF), where the restoring force that an ion experiences is proportional to the depth it travels into the LEF region. Consequently, the ion's equation of motion in that dimension is that of a simple harmonic oscillator and its travel time is simply proportional to the square root of the ion's mass/charge (m/q). While in an ideal LEF, the m/q resolution can be arbitrarily high, in a real device the resolution is limited by the field linearity which can be achieved. In this paper we describe how a nearly linear field can be produced and discuss how the design can be optimized for various different plasma regimes and spacecraft configurations

  9. High resolution CT of the chest

    Energy Technology Data Exchange (ETDEWEB)

    Barneveld Binkhuysen, F H [Eemland Hospital (Netherlands), Dept. of Radiology

    1996-12-31

    Compared to conventional CT high resolution CT (HRCT) shows several extra anatomical structures which might effect both diagnosis and therapy. The extra anatomical structures were discussed briefly in this article. (18 refs.).

  10. Methodology of high-resolution photography for mural condition database

    Science.gov (United States)

    Higuchi, R.; Suzuki, T.; Shibata, M.; Taniguchi, Y.

    2015-08-01

    Digital documentation is one of the most useful techniques to record the condition of cultural heritage. Recently, high-resolution images become increasingly useful because it is possible to show general views of mural paintings and also detailed mural conditions in a single image. As mural paintings are damaged by environmental stresses, it is necessary to record the details of painting condition on high-resolution base maps. Unfortunately, the cost of high-resolution photography and the difficulty of operating its instruments and software have commonly been an impediment for researchers and conservators. However, the recent development of graphic software makes its operation simpler and less expensive. In this paper, we suggest a new approach to make digital heritage inventories without special instruments, based on our recent our research project in Üzümlü church in Cappadocia, Turkey. This method enables us to achieve a high-resolution image database with low costs, short time, and limited human resources.

  11. High-Resolution MRI in Rectal Cancer

    International Nuclear Information System (INIS)

    Dieguez, Adriana

    2010-01-01

    High-resolution MRI is the best method of assessing the relation of the rectal tumor with the potential circumferential resection margin (CRM). Therefore it is currently considered the method of choice for local staging of rectal cancer. The primary surgery of rectal cancer is total mesorectal excision (TME), which plane of dissection is formed by the mesorectal fascia surrounding mesorectal fat and rectum. This fascia will determine the circumferential margin of resection. At the same time, high resolution MRI allows adequate pre-operative identification of important prognostic risk factors, improving the selection and indication of therapy for each patient. This information includes, besides the circumferential margin of resection, tumor and lymph node staging, extramural vascular invasion and the description of lower rectal tumors. All these should be described in detail in the report, being part of the discussion in the multidisciplinary team, the place where the decisions involving the patient with rectal cancer will take place. The aim of this study is to provide the information necessary to understand the use of high resolution MRI in the identification of prognostic risk factors in rectal cancer. The technical requirements and standardized report for this study will be describe, as well as the anatomical landmarks of importance for the total mesorectal excision (TME), as we have said is the surgery of choice for rectal cancer. (authors) [es

  12. Infantile hemangioendothelioma of liver

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Jin Mo; Kim, Woo Sun; Kim, In One; Yoon, Chong Hyun; Yeon, Kyung Mo; Choi, Choong Gon [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1993-05-15

    Radiologic findings of hemangioendothelioma of the liver were retrospectively analyzed in twelve infants. The radiological examinations included were sonography in 12 patients, computed tomography (CT) in six, magnetic resonance (MR) imaging in five, and angiography in two. Four patients were diagnosed pathologically, two by angiography, five by follow-up sonography, and one by clinical presentation with sonography. The common radiologic findings of the hemangioendothelioma were well circumscribed heterogeneous echogenic mass (75%) on sonography, peripheral massive enhancement (67%) on CT, bright high signal intensity on T2-weighted MR image (100%), and homogenous or peripheral enhancement (75%) on Gd-DTPA enhanced T1-weighted MR image. Dilated proximal aorta and enlarged draining hepatic veins on angiography and other studies were also important findings. The follow-up sonography demonstrated the involution of lesions with some calcification in four patients and complete resolution in one. The authors believe that these findings in an infant under the age of 6 months strongly suggest the diagnosis of hemangioendothelioma of the liver, and follow-up sonography should be done.

  13. High-resolution coherent three-dimensional spectroscopy of Br2.

    Science.gov (United States)

    Chen, Peter C; Wells, Thresa A; Strangfeld, Benjamin R

    2013-07-25

    In the past, high-resolution spectroscopy has been limited to small, simple molecules that yield relatively uncongested spectra. Larger and more complex molecules have a higher density of peaks and are susceptible to complications (e.g., effects from conical intersections) that can obscure the patterns needed to resolve and assign peaks. Recently, high-resolution coherent two-dimensional (2D) spectroscopy has been used to resolve and sort peaks into easily identifiable patterns for molecules where pattern-recognition has been difficult. For very highly congested spectra, however, the ability to resolve peaks using coherent 2D spectroscopy is limited by the bandwidth of instrumentation. In this article, we introduce and investigate high-resolution coherent three-dimensional spectroscopy (HRC3D) as a method for dealing with heavily congested systems. The resulting patterns are unlike those in high-resolution coherent 2D spectra. Analysis of HRC3D spectra could provide a means for exploring the spectroscopy of large and complex molecules that have previously been considered too difficult to study.

  14. High resolution gamma-ray spectroscopy at high count rates with a prototype High Purity Germanium detector

    Science.gov (United States)

    Cooper, R. J.; Amman, M.; Vetter, K.

    2018-04-01

    High-resolution gamma-ray spectrometers are required for applications in nuclear safeguards, emergency response, and fundamental nuclear physics. To overcome one of the shortcomings of conventional High Purity Germanium (HPGe) detectors, we have developed a prototype device capable of achieving high event throughput and high energy resolution at very high count rates. This device, the design of which we have previously reported on, features a planar HPGe crystal with a reduced-capacitance strip electrode geometry. This design is intended to provide good energy resolution at the short shaping or digital filter times that are required for high rate operation and which are enabled by the fast charge collection afforded by the planar geometry crystal. In this work, we report on the initial performance of the system at count rates up to and including two million counts per second.

  15. Detectors for high resolution dynamic pet

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.; Huesman, R.H.

    1983-05-01

    This report reviews the motivation for high spatial resolution in dynamic positron emission tomography of the head and the technical problems in realizing this objective. We present recent progress in using small silicon photodiodes to measure the energy deposited by 511 keV photons in small BGO crystals with an energy resolution of 9.4% full-width at half-maximum. In conjunction with a suitable phototube coupled to a group of crystals, the photodiode signal to noise ratio is sufficient for the identification of individual crystals both for conventional and time-of-flight positron tomography

  16. High Resolution Thermometry for EXACT

    Science.gov (United States)

    Panek, J. S.; Nash, A. E.; Larson, M.; Mulders, N.

    2000-01-01

    High Resolution Thermometers (HRTs) based on SQUID detection of the magnetization of a paramagnetic salt or a metal alloy has been commonly used for sub-nano Kelvin temperature resolution in low temperature physics experiments. The main applications to date have been for temperature ranges near the lambda point of He-4 (2.177 K). These thermometers made use of materials such as Cu(NH4)2Br4 *2H2O, GdCl3, or PdFe. None of these materials are suitable for EXACT, which will explore the region of the He-3/He-4 tricritical point at 0.87 K. The experiment requirements and properties of several candidate paramagnetic materials will be presented, as well as preliminary test results.

  17. Tc-99m DTPA perfusion scintigraphy and color coded duplex sonography in the evaluation of minimal renal allograft perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Bair, H.J.; Platsch, G.; Wolf, F. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Nuclear Medicine; Guenter, E.; Becker, D. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Internal Medicine 1; Rupprecht, H.; Neumayer, H.H. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Internal Medicine 4

    1997-08-01

    Aim: The clinical impact of perfusion scintigraphy versus color coded Duplex sonography was evaluated, with respect to their potential in assessing minimal allograft perfusion in vitally threatened kidney transplants, i.e. oligoanuric allografts suspected to have either severe rejection or thrombosis of the renal vein or artery. Methods: From July 1990 to August 1994 the grafts of 15 out of a total of 315 patients were vitally threatened. Technetium-99m DTPA scintigraphy and color coded Duplex sonography were performed in all patients. For scintigraphic evaluation of transplant perfusion analog scans up to 60 min postinjection, and time-activity curves over the first 60 sec after injection of 370-440 MBq Tc-99m diethylenetriaminepentaacetate acid (DTPA) were used and classified by a perfusion score, the time between renal and iliac artery peaks (TDiff) and the washout of the renogram curve. Additionally, evaluation of excretion function and assessment of vascular or urinary leaks were performed. By color coded Duplex sonography the perfusion in all sections of the graft as well as the vascular anastomoses were examined and the maximal blood flow velocity (Vmax) and the resistive index (RI) in the renal artery were determined by means of the pulsed Doppler device. Pathologic-anatomical diagnosis was achieved by either biopsy or post-explant histology in all grafts. Results: Scintigraphy and color coded Duplex sonography could reliably differentiate minimal (8/15) and not perfused (7/15) renal allografts. The results were confirmed either by angiography in digital subtraction technique (DSA) or the clinical follow up. Conclusion: In summary, perfusion scintigraphy and color coded Duplex sonography are comparable modalities to assess kidney graft perfusion. In clinical practice scintigraphy and colorcoded Doppler sonography can replace digital subtraction angiography in the evaluation of minimal allograft perfusion. (orig.) [Deutsch] Ziel der Studie war es, das

  18. High temperature and high resolution uv photoelectron spectroscopy using supersonic molecular beams

    International Nuclear Information System (INIS)

    Wang, Lai-Sheng; Reutt-Robey, J.E.; Niu, B.; Lee, Y.T.; Shirley, D.A.

    1989-07-01

    A high temperature molecular beam source with electron bombardment heating has been built for high resolution photoelectron spectroscopic studies of high temperature species and clusters. This source has the advantages of: producing an intense, continuous, seeded molecular beam, eliminating the interference of the heating mechanism from the photoelectron measurement. Coupling the source with our hemispherical electron energy analyzer, we can obtain very high resolution HeIα (584 angstrom) photoelectron spectra of high temperature species. Vibrationally-resolved photoelectron spectra of PbSe, As 2 , As 4 , and ZnCl 2 are shown to demonstrate the performance of the new source. 25 refs., 8 figs., 1 tab

  19. Ribbon scanning confocal for high-speed high-resolution volume imaging of brain.

    Directory of Open Access Journals (Sweden)

    Alan M Watson

    Full Text Available Whole-brain imaging is becoming a fundamental means of experimental insight; however, achieving subcellular resolution imagery in a reasonable time window has not been possible. We describe the first application of multicolor ribbon scanning confocal methods to collect high-resolution volume images of chemically cleared brains. We demonstrate that ribbon scanning collects images over ten times faster than conventional high speed confocal systems but with equivalent spectral and spatial resolution. Further, using this technology, we reconstruct large volumes of mouse brain infected with encephalitic alphaviruses and demonstrate that regions of the brain with abundant viral replication were inaccessible to vascular perfusion. This reveals that the destruction or collapse of large regions of brain micro vasculature may contribute to the severe disease caused by Venezuelan equine encephalitis virus. Visualization of this fundamental impact of infection would not be possible without sampling at subcellular resolution within large brain volumes.

  20. High resolution tsunami inversion for 2010 Chile earthquake

    Directory of Open Access Journals (Sweden)

    T.-R. Wu

    2011-12-01

    Full Text Available We investigate the feasibility of inverting high-resolution vertical seafloor displacement from tsunami waveforms. An inversion method named "SUTIM" (small unit tsunami inversion method is developed to meet this goal. In addition to utilizing the conventional least-square inversion, this paper also enhances the inversion resolution by Grid-Shifting method. A smooth constraint is adopted to gain stability. After a series of validation and performance tests, SUTIM is used to study the 2010 Chile earthquake. Based upon data quality and azimuthal distribution, we select tsunami waveforms from 6 GLOSS stations and 1 DART buoy record. In total, 157 sub-faults are utilized for the high-resolution inversion. The resolution reaches 10 sub-faults per wavelength. The result is compared with the distribution of the aftershocks and waveforms at each gauge location with very good agreement. The inversion result shows that the source profile features a non-uniform distribution of the seafloor displacement. The highly elevated vertical seafloor is mainly concentrated in two areas: one is located in the northern part of the epicentre, between 34° S and 36° S; the other is in the southern part, between 37° S and 38° S.

  1. High resolution tsunami inversion for 2010 Chile earthquake

    Science.gov (United States)

    Wu, T.-R.; Ho, T.-C.

    2011-12-01

    We investigate the feasibility of inverting high-resolution vertical seafloor displacement from tsunami waveforms. An inversion method named "SUTIM" (small unit tsunami inversion method) is developed to meet this goal. In addition to utilizing the conventional least-square inversion, this paper also enhances the inversion resolution by Grid-Shifting method. A smooth constraint is adopted to gain stability. After a series of validation and performance tests, SUTIM is used to study the 2010 Chile earthquake. Based upon data quality and azimuthal distribution, we select tsunami waveforms from 6 GLOSS stations and 1 DART buoy record. In total, 157 sub-faults are utilized for the high-resolution inversion. The resolution reaches 10 sub-faults per wavelength. The result is compared with the distribution of the aftershocks and waveforms at each gauge location with very good agreement. The inversion result shows that the source profile features a non-uniform distribution of the seafloor displacement. The highly elevated vertical seafloor is mainly concentrated in two areas: one is located in the northern part of the epicentre, between 34° S and 36° S; the other is in the southern part, between 37° S and 38° S.

  2. Concept for a new high resolution high intensity diffractometer

    Energy Technology Data Exchange (ETDEWEB)

    Stuhr, U [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    A concept of a new time-of-flight powder-diffractometer for a thermal neutral beam tube at SINQ is presented. The design of the instrument optimises the contradictory conditions of high intensity and high resolution. The high intensity is achieved by using many neutron pulses simultaneously. By analysing the time-angle-pattern of the detected neutrons an assignment of the neutrons to a single pulse is possible. (author) 3 figs., tab., refs.

  3. Volumetric expiratory high-resolution CT of the lung

    International Nuclear Information System (INIS)

    Nishino, Mizuki; Hatabu, Hiroto

    2004-01-01

    We developed a volumetric expiratory high-resolution CT (HRCT) protocol that provides combined inspiratory and expiratory volumetric imaging of the lung without increasing radiation exposure, and conducted a preliminary feasibility assessment of this protocol to evaluate diffuse lung disease with small airway abnormalities. The volumetric expiratory high-resolution CT increased the detectability of the conducting airway to the areas of air trapping (P<0.0001), and added significant information about extent and distribution of air trapping (P<0.0001)

  4. Developing Visual Editors for High-Resolution Haptic Patterns

    DEFF Research Database (Denmark)

    Cuartielles, David; Göransson, Andreas; Olsson, Tony

    2012-01-01

    In this article we give an overview of our iterative work in developing visual editors for creating high resolution haptic patterns to be used in wearable, haptic feedback devices. During the past four years we have found the need to address the question of how to represent, construct and edit high...... resolution haptic patterns so that they translate naturally to the user’s haptic experience. To solve this question we have developed and tested several visual editors...

  5. High resolution SETI: Experiences and prospects

    Science.gov (United States)

    Horowitz, Paul; Clubok, Ken

    Megachannel spectroscopy with sub-Hertz resolution constitutes an attractive strategy for a microwave search for extraterrestrial intelligence (SETI), assuming the transmission of a narrowband radiofrequency beacon. Such resolution matches the properties of the interstellar medium, and the necessary Doppler corrections provide a high degree of interference rejection. We have constructed a frequency-agile receiver with an FFT-based 8 megachannel digital spectrum analyzer, on-line signal recognition, and multithreshold archiving. We are using it to conduct a meridian transit search of the northern sky at the Harvard-Smithsonian 26-m antenna, with a second identical system scheduled to begin observations in Argentina this month. Successive 400 kHz spectra, at 0.05 Hz resolution, are searched for features characteristic of an intentional narrowband beacon transmission. These spectra are centered on guessable frequencies (such as λ21 cm), referenced successively to the local standard of rest, the galactic barycenter, and the cosmic blackbody rest frame. This search has rejected interference admirably, but is greatly limited both in total frequency coverage and sensitivity to signals other than carriers. We summarize five years of high resolution SETI at Harvard, in the context of answering the questions "How useful is narrowband SETI, how serious are its limitations, what can be done to circumvent them, and in what direction should SETI evolve?" Increasingly powerful signal processing hardware, combined with ever-higher memory densities, are particularly relevant, permitting the construction of compact and affordable gigachannel spectrum analyzers covering hundreds of megahertz of instantaneous bandwidth.

  6. The high-resolution regional reanalysis COSMO-REA6

    Science.gov (United States)

    Ohlwein, C.

    2016-12-01

    Reanalyses gain more and more importance as a source of meteorological information for many purposes and applications. Several global reanalyses projects (e.g., ERA, MERRA, CSFR, JMA9) produce and verify these data sets to provide time series as long as possible combined with a high data quality. Due to a spatial resolution down to 50-70km and 3-hourly temporal output, they are not suitable for small scale problems (e.g., regional climate assessment, meso-scale NWP verification, input for subsequent models such as river runoff simulations). The implementation of regional reanalyses based on a limited area model along with a data assimilation scheme is able to generate reanalysis data sets with high spatio-temporal resolution. Within the Hans-Ertel-Centre for Weather Research (HErZ), the climate monitoring branch concentrates efforts on the assessment and analysis of regional climate in Germany and Europe. In joint cooperation with DWD (German Meteorological Service), a high-resolution reanalysis system based on the COSMO model has been developed. The regional reanalysis for Europe matches the domain of the CORDEX EURO-11 specifications, albeit at a higher spatial resolution, i.e., 0.055° (6km) instead of 0.11° (12km) and comprises the assimilation of observational data using the existing nudging scheme of COSMO complemented by a special soil moisture analysis with boundary conditions provided by ERA-Interim data. The reanalysis data set covers the past 20 years. Extensive evaluation of the reanalysis is performed using independent observations with special emphasis on precipitation and high-impact weather situations indicating a better representation of small scale variability. Further, the evaluation shows an added value of the regional reanalysis with respect to the forcing ERA Interim reanalysis and compared to a pure high-resolution dynamical downscaling approach without data assimilation.

  7. A comparison of magnetic resonance imaging, sonography, and radiography of the hand in patients with early rheumatoid arthritis

    NARCIS (Netherlands)

    Hoving, Jan Lucas; Buchbinder, Rachelle; Hall, Stephen; Lawler, Gary; Coombs, Peter; McNealy, Stephen; Bird, Paul; Connell, David

    2004-01-01

    OBJECTIVE: As therapy for rheumatoid arthritis (RA) becomes more effective, more sensitive imaging methods are required to assess disease activity and joint damage. We compared magnetic resonance imaging (MRI), sonography, and radiography for assessment of disease activity for the detection of bony

  8. Transcranial Doppler sonography as diagnostic method

    Directory of Open Access Journals (Sweden)

    Jasminka Đelilović-Vranić

    2002-02-01

    Full Text Available Having in mind the fact that cerebrovascular disease (CVB takes today in medicine, in spite of diagnostic and therapeutic modernisation, the third place of mortality causes in the world (behind cordial and malignant diseases, but in front of depressions, and the second place of invalidity cause (right after trauma as well as the second place of dementia cause (after Alzheimer disease, it urges primary prophylaxis. Developing countries, but before all countries of East and Middle Europe, where is our country, are highly risked areas where CV disease has trend of incidence and total frequency increase. In the neighbouring Croatia today CV disease is at the first place of mortality causes. In the world today 5 million people annually suffer CV disease, in Europe about 700.000, but frequency of suffering on Balkan is about 5 prom. Age of CV disease effecting unfortunately moved towards young age, and today 49% of effected by CV disease are of 46 to 59 years of age. Early detection and treatment of risk factors (before hypertension, smoking, diabetes mellitus, hyperlipidaemia, stress and physical non-activities are the first aspect of CV disease prophylaxis. Together with this aspect of primary prophylaxis is early detection of complications of mentioned risk factors on the walls of blood vessels, before all changing in sense of arteriosclerosis, with consequence of disorder of cerebral haemodynamics. With that objective - verification of circulator and total haemodynamic disorders, there is obvious disclose of non-invasive diagnostic methods, and one of them is Transcranial Doppler Sonography(TCD. TCD is method comfortable for patient, reliable and rather precise, dynamic, and can be repeated several times, without side effects and in comparison with others rather cheap.

  9. SRS station 16.3: high-resolution applications

    CERN Document Server

    Murphy, B M; Golshan, M; Moore, M; Reid, J; Kowalski, G

    2001-01-01

    Station 16.3 is a high-resolution X-ray diffraction beamline at Daresbury Laboratory Synchrotron Radiation Source. The data presented demonstrate the high-resolution available on the station utilising the recently commissioned four-reflection Si 1 1 1 monochromator and three-reflection Si 1 1 1 analyser. For comparison, a reciprocal space map of the two-bounce Si 1 1 1 monochromator and two-bounce analyser is also shown. Operation of the station is illustrated with examples for silicon, and for diamond. Lattice parameter variations were measured with accuracies in the part per million range and lattice tilts at the arc second level (DuMond, Phys. Rev. 52 (1937) 872).

  10. High-resolution X-ray crystal structure of bovine H-protein using the high-pressure cryocooling method.

    Science.gov (United States)

    Higashiura, Akifumi; Ohta, Kazunori; Masaki, Mika; Sato, Masaru; Inaka, Koji; Tanaka, Hiroaki; Nakagawa, Atsushi

    2013-11-01

    Recently, many technical improvements in macromolecular X-ray crystallography have increased the number of structures deposited in the Protein Data Bank and improved the resolution limit of protein structures. Almost all high-resolution structures have been determined using a synchrotron radiation source in conjunction with cryocooling techniques, which are required in order to minimize radiation damage. However, optimization of cryoprotectant conditions is a time-consuming and difficult step. To overcome this problem, the high-pressure cryocooling method was developed (Kim et al., 2005) and successfully applied to many protein-structure analyses. In this report, using the high-pressure cryocooling method, the X-ray crystal structure of bovine H-protein was determined at 0.86 Å resolution. Structural comparisons between high- and ambient-pressure cryocooled crystals at ultra-high resolution illustrate the versatility of this technique. This is the first ultra-high-resolution X-ray structure obtained using the high-pressure cryocooling method.

  11. Resolution-recovery-embedded image reconstruction for a high-resolution animal SPECT system.

    Science.gov (United States)

    Zeraatkar, Navid; Sajedi, Salar; Farahani, Mohammad Hossein; Arabi, Hossein; Sarkar, Saeed; Ghafarian, Pardis; Rahmim, Arman; Ay, Mohammad Reza

    2014-11-01

    The small-animal High-Resolution SPECT (HiReSPECT) is a dedicated dual-head gamma camera recently designed and developed in our laboratory for imaging of murine models. Each detector is composed of an array of 1.2 × 1.2 mm(2) (pitch) pixelated CsI(Na) crystals. Two position-sensitive photomultiplier tubes (H8500) are coupled to each head's crystal. In this paper, we report on a resolution-recovery-embedded image reconstruction code applicable to the system and present the experimental results achieved using different phantoms and mouse scans. Collimator-detector response functions (CDRFs) were measured via a pixel-driven method using capillary sources at finite distances from the head within the field of view (FOV). CDRFs were then fitted by independent Gaussian functions. Thereafter, linear interpolations were applied to the standard deviation (σ) values of the fitted Gaussians, yielding a continuous map of CDRF at varying distances from the head. A rotation-based maximum-likelihood expectation maximization (MLEM) method was used for reconstruction. A fast rotation algorithm was developed to rotate the image matrix according to the desired angle by means of pre-generated rotation maps. The experiments demonstrated improved resolution utilizing our resolution-recovery-embedded image reconstruction. While the full-width at half-maximum (FWHM) radial and tangential resolution measurements of the system were over 2 mm in nearly all positions within the FOV without resolution recovery, reaching around 2.5 mm in some locations, they fell below 1.8 mm everywhere within the FOV using the resolution-recovery algorithm. The noise performance of the system was also acceptable; the standard deviation of the average counts per voxel in the reconstructed images was 6.6% and 8.3% without and with resolution recovery, respectively. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  12. A novel decision tree approach based on transcranial Doppler sonography to screen for blunt cervical vascular injuries.

    Science.gov (United States)

    Purvis, Dianna; Aldaghlas, Tayseer; Trickey, Amber W; Rizzo, Anne; Sikdar, Siddhartha

    2013-06-01

    Early detection and treatment of blunt cervical vascular injuries prevent adverse neurologic sequelae. Current screening criteria can miss up to 22% of these injuries. The study objective was to investigate bedside transcranial Doppler sonography for detecting blunt cervical vascular injuries in trauma patients using a novel decision tree approach. This prospective pilot study was conducted at a level I trauma center. Patients undergoing computed tomographic angiography for suspected blunt cervical vascular injuries were studied with transcranial Doppler sonography. Extracranial and intracranial vasculatures were examined with a portable power M-mode transcranial Doppler unit. The middle cerebral artery mean flow velocity, pulsatility index, and their asymmetries were used to quantify flow patterns and develop an injury decision tree screening protocol. Student t tests validated associations between injuries and transcranial Doppler predictive measures. We evaluated 27 trauma patients with 13 injuries. Single vertebral artery injuries were most common (38.5%), followed by single internal carotid artery injuries (30%). Compared to patients without injuries, mean flow velocity asymmetry was higher for single internal carotid artery (P = .003) and single vertebral artery (P = .004) injuries. Similarly, pulsatility index asymmetry was higher in single internal carotid artery (P = .015) and single vertebral artery (P = .042) injuries, whereas the lowest pulsatility index was elevated for bilateral vertebral artery injuries (P = .006). The decision tree yielded 92% specificity, 93% sensitivity, and 93% correct classifications. In this pilot feasibility study, transcranial Doppler measures were significantly associated with the blunt cervical vascular injury status, suggesting that transcranial Doppler sonography might be a viable bedside screening tool for trauma. Patient-specific hemodynamic information from transcranial Doppler assessment has the potential to alter

  13. High-resolution electron microscopy of advanced materials

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, T.E.; Kung, H.H.; Sickafus, K.E.; Gray, G.T. III; Field, R.D.; Smith, J.F. [Los Alamos National Lab., NM (United States). Materials Science and Technology Div.

    1997-11-01

    This final report chronicles a three-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The High-Resolution Electron Microscopy Facility has doubled in size and tripled in quality since the beginning of the three-year period. The facility now includes a field-emission scanning electron microscope, a 100 kV field-emission scanning transmission electron microscope (FE-STEM), a 300 kV field-emission high-resolution transmission electron microscope (FE-HRTEM), and a 300 kV analytical transmission electron microscope. A new orientation imaging microscope is being installed. X-ray energy dispersive spectrometers for chemical analysis are available on all four microscopes; parallel electron energy loss spectrometers are operational on the FE-STEM and FE-HRTEM. These systems enable evaluation of local atomic bonding, as well as chemical composition in nanometer-scale regions. The FE-HRTEM has a point-to-point resolution of 1.6 {angstrom}, but the resolution can be pushed to its information limit of 1 {angstrom} by computer reconstruction of a focal series of images. HRTEM has been used to image the atomic structure of defects such as dislocations, grain boundaries, and interfaces in a variety of materials from superconductors and ferroelectrics to structural ceramics and intermetallics.

  14. High Resolution PET with 250 micrometer LSO Detectors and Adaptive Zoom

    International Nuclear Information System (INIS)

    Cherry, Simon R.; Qi, Jinyi

    2012-01-01

    There have been impressive improvements in the performance of small-animal positron emission tomography (PET) systems since their first development in the mid 1990s, both in terms of spatial resolution and sensitivity, which have directly contributed to the increasing adoption of this technology for a wide range of biomedical applications. Nonetheless, current systems still are largely dominated by the size of the scintillator elements used in the detector. Our research predicts that developing scintillator arrays with an element size of 250 (micro)m or smaller will lead to an image resolution of 500 (micro)m when using 18F- or 64Cu-labeled radiotracers, giving a factor of 4-8 improvement in volumetric resolution over the highest resolution research systems currently in existence. This proposal had two main objectives: (i) To develop and evaluate much higher resolution and efficiency scintillator arrays that can be used in the future as the basis for detectors in a small-animal PET scanner where the spatial resolution is dominated by decay and interaction physics rather than detector size. (ii) To optimize one such high resolution, high sensitivity detector and adaptively integrate it into the existing microPET II small animal PET scanner as a 'zoom-in' detector that provides higher spatial resolution and sensitivity in a limited region close to the detector face. The knowledge gained from this project will provide valuable information for building future PET systems with a complete ring of very high-resolution detector arrays and also lay the foundations for utilizing high-resolution detectors in combination with existing PET systems for localized high-resolution imaging.

  15. Achieving High Resolution Timer Events in Virtualized Environment.

    Science.gov (United States)

    Adamczyk, Blazej; Chydzinski, Andrzej

    2015-01-01

    Virtual Machine Monitors (VMM) have become popular in different application areas. Some applications may require to generate the timer events with high resolution and precision. This however may be challenging due to the complexity of VMMs. In this paper we focus on the timer functionality provided by five different VMMs-Xen, KVM, Qemu, VirtualBox and VMWare. Firstly, we evaluate resolutions and precisions of their timer events. Apparently, provided resolutions and precisions are far too low for some applications (e.g. networking applications with the quality of service). Then, using Xen virtualization we demonstrate the improved timer design that greatly enhances both the resolution and precision of achieved timer events.

  16. Value of sonography in establishing severity of liver cirrhosis:correlation of sonographic features with Childclass

    International Nuclear Information System (INIS)

    Choi, Byung Ihn; KIm, Ho Chul; Shin, Yong Moon; Kim, Chu Wan; Lee, Hyo suk; Kim, Chung Yong

    1993-01-01

    This prospective study was designed to investigate the utility of sonography in establishing severity of liver cirrhosis as compared with Child class in clinical creteria. Seventy-our consecutive patients with liver cirrhosis were examined with sonography. This study included 50 males and 24 females, aged 35 to 72 years (mean ; 51) The number of patients in child A,B, and C group was 30,29,15 respectively. Sonographic features evaluated were hepatic parenchymal echo pattern, presence of nodularity of hepatic surface, degree of hepatic sonic attenuation,degree of obliteration of wall echo of the intrahepatic portal vein, size of the main portal vein, thickness of the gallbladder wall, size of the spleen, and presence of ascites. Each sonographic features was graded from 0 to depending upon the degree of severity, and was correlated with Child class of liver cirrhosis. Hepatic parenchymal echo pattern, presence of nodularity of hepatic surface, thickness of gallbladder wall, and presence of ascites were correlated well with Child class (p 0.05). In conclusion, these results indicate that careful evaluation of sonographic features are helpful in predicting severity of liver cirrhosis

  17. Compact and high-resolution optical orbital angular momentum sorter

    Directory of Open Access Journals (Sweden)

    Chenhao Wan

    2017-03-01

    Full Text Available A compact and high-resolution optical orbital angular momentum (OAM sorter is proposed and demonstrated. The sorter comprises a quadratic fan-out mapper and a dual-phase corrector positioned in the pupil plane and the Fourier plane, respectively. The optical system is greatly simplified compared to previous demonstrations of OAM sorting, and the performance in resolution and efficiency is maintained. A folded configuration is set up using a single reflective spatial light modulator (SLM to demonstrate the validity of the scheme. The two phase elements are implemented on the left and right halves of the SLM and connected by a right-angle prism. Experimental results demonstrate the high resolution of the compact OAM sorter, and the current limit in efficiency can be overcome by replacing with transmissive SLMs and removing the beam splitters. This novel scheme paves the way for the miniaturization and integration of high-resolution OAM sorters.

  18. High resolution manometry findings in patients with esophageal epiphrenic diverticula.

    Science.gov (United States)

    Vicentine, Fernando P P; Herbella, Fernando A M; Silva, Luciana C; Patti, Marco G

    2011-12-01

    The pathophysiology of esophageal epiphrenic diverticula is still uncertain even though a concomitant motility disorder is found in the majority of patients in different series. High resolution manometry may allow detection of motor abnormalities in a higher number of patients with esophageal epiphrenic diverticula compared with conventional manometry. This study aims to evaluate the high resolution manometry findings in patients with esophageal epiphrenic diverticula. Nine individuals (mean age 63 ± 10 years, 4 females) with esophageal epiphrenic diverticula underwent high resolution manometry. A single diverticulum was observed in eight patients and multiple diverticula in one. Visual analysis of conventional tracings and color pressure plots for identification of segmental abnormalities was performed by two researchers experienced in high resolution manometry. Upper esophageal sphincter was normal in all patients. Esophageal body was abnormal in eight patients; lower esophageal sphincter was abnormal in seven patients. Named esophageal motility disorders were found in seven patients: achalasia in six, diffuse esophageal spasm in one. In one patient, a segmental hypercontractile zone was noticed with pressure of 196 mm Hg. High resolution manometry demonstrated motor abnormalities in all patients with esophageal epiphrenic diverticula.

  19. Constraining Stochastic Parametrisation Schemes Using High-Resolution Model Simulations

    Science.gov (United States)

    Christensen, H. M.; Dawson, A.; Palmer, T.

    2017-12-01

    Stochastic parametrisations are used in weather and climate models as a physically motivated way to represent model error due to unresolved processes. Designing new stochastic schemes has been the target of much innovative research over the last decade. While a focus has been on developing physically motivated approaches, many successful stochastic parametrisation schemes are very simple, such as the European Centre for Medium-Range Weather Forecasts (ECMWF) multiplicative scheme `Stochastically Perturbed Parametrisation Tendencies' (SPPT). The SPPT scheme improves the skill of probabilistic weather and seasonal forecasts, and so is widely used. However, little work has focused on assessing the physical basis of the SPPT scheme. We address this matter by using high-resolution model simulations to explicitly measure the `error' in the parametrised tendency that SPPT seeks to represent. The high resolution simulations are first coarse-grained to the desired forecast model resolution before they are used to produce initial conditions and forcing data needed to drive the ECMWF Single Column Model (SCM). By comparing SCM forecast tendencies with the evolution of the high resolution model, we can measure the `error' in the forecast tendencies. In this way, we provide justification for the multiplicative nature of SPPT, and for the temporal and spatial scales of the stochastic perturbations. However, we also identify issues with the SPPT scheme. It is therefore hoped these measurements will improve both holistic and process based approaches to stochastic parametrisation. Figure caption: Instantaneous snapshot of the optimal SPPT stochastic perturbation, derived by comparing high-resolution simulations with a low resolution forecast model.

  20. Sonographic diagnosis of neonatal ovarian cysts: Two cases of spontaneous resolution

    International Nuclear Information System (INIS)

    Nussbaum, A.R.; Sanders, R.C.; Hartman, D.S.; Dudgeon, D.L.; Haller, J.A. Jr.

    1986-01-01

    Sonography established the diagnosis of an ovarian cyst in 12 infants. In two, spontaneous resolution over a 2- to 4-month interval was documented. Six cysts were discovered prenatally and confirmed postnatally, and six were identified in neonates with a palpable abdominal mass or distention. Ten masses were intra-abdominal; two were pelvic in location. The cyst size ranged from 2 to 10 cm in diameter. The cyst was spherical and unilateral in 11 of 12 infants and dumbbell-shaped and bilateral in one infant. Four cysts were anechoic and eight hemorrhagic or torsed cysts were complex or echogenic. In two hemorrhagic cysts a fluid-debris level was detected, and three were septated

  1. High-resolution flood modeling of urban areas using MSN_Flood

    Directory of Open Access Journals (Sweden)

    Michael Hartnett

    2017-07-01

    Full Text Available Although existing hydraulic models have been used to simulate and predict urban flooding, most of these models are inadequate due to the high spatial resolution required to simulate flows in urban floodplains. Nesting high-resolution subdomains within coarser-resolution models is an efficient solution for enabling simultaneous calculation of flooding due to tides, surges, and high river flows. MSN_Flood has been developed to incorporate moving boundaries around nested domains, permitting alternate flooding and drying along the boundary and in the interior of the domain. Ghost cells adjacent to open boundary cells convert open boundaries, in effect, into internal boundaries. The moving boundary may be multi-segmented and non-continuous, with recirculating flow across the boundary. When combined with a bespoke adaptive interpolation scheme, this approach facilitates a dynamic internal boundary. Based on an alternating-direction semi-implicit finite difference scheme, MSN_Flood was used to hindcast a major flood event in Cork City resulting from the combined pressures of fluvial, tidal, and storm surge processes. The results show that the model is computationally efficient, as the 2-m high-resolution nest is used only in the urban flooded region. Elsewhere, lower-resolution nests are used. The results also show that the model is highly accurate when compared with measured data. The model is capable of incorporating nested sub-domains when the nested boundary is multi-segmented and highly complex with lateral gradients of elevation and velocities. This is a major benefit when modelling urban floodplains at very high resolution.

  2. Reproducible high-resolution multispectral image acquisition in dermatology

    Science.gov (United States)

    Duliu, Alexandru; Gardiazabal, José; Lasser, Tobias; Navab, Nassir

    2015-07-01

    Multispectral image acquisitions are increasingly popular in dermatology, due to their improved spectral resolution which enables better tissue discrimination. Most applications however focus on restricted regions of interest, imaging only small lesions. In this work we present and discuss an imaging framework for high-resolution multispectral imaging on large regions of interest.

  3. High Resolution Energetic X-ray Imager (HREXI)

    Science.gov (United States)

    Grindlay, Jonathan

    We propose to design and build the first imaging hard X-ray detector system that incorporates 3D stacking of closely packed detector readouts in finely-spaced imaging arrays with their required data processing and control electronics. In virtually all imaging astronomical detectors, detector readout is done with flex connectors or connections that are not vertical but rather horizontal , requiring loss of focal plane area. For high resolution pixel detectors needed for high speed event-based X-ray imaging, from low energy applications (CMOS) with focusing X-ray telescopes, to hard X-ray applications with pixelated CZT for large area coded aperture telescopes, this new detector development offers great promise. We propose to extend our previous and current APRA supported ProtoEXIST program that has developed the first large area imaging CZT detectors and demonstrated their astrophysical capabilities on two successful balloon flight to a next generation High Resolution Energetic X-ray Imager (HREXI), which would incorporate microvia technology for the first time to connect the readout ASIC on each CZT crystal directly to its control and data processing system. This 3-dimensional stacking of detector and readout/control system means that large area (>2m2) imaging detector planes for a High Resolution Wide-field hard X-ray telescope can be built with initially greatly reduced detector gaps and ultimately with no gaps. This increases detector area, efficiency, and simplicity of detector integration. Thus higher sensitivity wide-field imagers will be possible at lower cost. HREXI will enable a post-Swift NASA mission such as the EREXS concept proposed to PCOS to be conducted as a future MIDEX mission. This mission would conduct a high resolution (<2 arcmin) , broad band (5 200 keV) hard X-ray survey of black holes on all scales with ~10X higher sensitivity than Swift. In the current era of Time Domain Astrophysics, such a survey capability, in conjunction with a n

  4. High-resolution investigations of edge effects in neutron imaging

    International Nuclear Information System (INIS)

    Strobl, M.; Kardjilov, N.; Hilger, A.; Kuehne, G.; Frei, G.; Manke, I.

    2009-01-01

    Edge enhancement is the main effect measured by the so-called inline or propagation-based neutron phase contrast imaging method. The effect has originally been explained by diffraction, and high spatial coherence has been claimed to be a necessary precondition. However, edge enhancement has also been found in conventional imaging with high resolution. In such cases the effects can produce artefacts and hinder quantification. In this letter the edge effects at cylindrical shaped samples and long straight edges have been studied in detail. The enhancement can be explained by refraction and total reflection. Using high-resolution imaging, where spatial resolutions better than 50 μm could be achieved, refraction and total reflection peaks - similar to diffraction patterns - could be separated and distinguished.

  5. High-Resolution Adaptive Optics Test-Bed for Vision Science

    International Nuclear Information System (INIS)

    Wilks, S.C.; Thomspon, C.A.; Olivier, S.S.; Bauman, B.J.; Barnes, T.; Werner, J.S.

    2001-01-01

    We discuss the design and implementation of a low-cost, high-resolution adaptive optics test-bed for vision research. It is well known that high-order aberrations in the human eye reduce optical resolution and limit visual acuity. However, the effects of aberration-free eyesight on vision are only now beginning to be studied using adaptive optics to sense and correct the aberrations in the eye. We are developing a high-resolution adaptive optics system for this purpose using a Hamamatsu Parallel Aligned Nematic Liquid Crystal Spatial Light Modulator. Phase-wrapping is used to extend the effective stroke of the device, and the wavefront sensing and wavefront correction are done at different wavelengths. Issues associated with these techniques will be discussed

  6. Ultra-high resolution AMOLED

    Science.gov (United States)

    Wacyk, Ihor; Prache, Olivier; Ghosh, Amal

    2011-06-01

    AMOLED microdisplays continue to show improvement in resolution and optical performance, enhancing their appeal for a broad range of near-eye applications such as night vision, simulation and training, situational awareness, augmented reality, medical imaging, and mobile video entertainment and gaming. eMagin's latest development of an HDTV+ resolution technology integrates an OLED pixel of 3.2 × 9.6 microns in size on a 0.18 micron CMOS backplane to deliver significant new functionality as well as the capability to implement a 1920×1200 microdisplay in a 0.86" diagonal area. In addition to the conventional matrix addressing circuitry, the HDTV+ display includes a very lowpower, low-voltage-differential-signaling (LVDS) serialized interface to minimize cable and connector size as well as electromagnetic emissions (EMI), an on-chip set of look-up-tables for digital gamma correction, and a novel pulsewidth- modulation (PWM) scheme that together with the standard analog control provides a total dimming range of 0.05cd/m2 to 2000cd/m2 in the monochrome version. The PWM function also enables an impulse drive mode of operation that significantly reduces motion artifacts in high speed scene changes. An internal 10-bit DAC ensures that a full 256 gamma-corrected gray levels are available across the entire dimming range, resulting in a measured dynamic range exceeding 20-bits. This device has been successfully tested for operation at frame rates ranging from 30Hz up to 85Hz. This paper describes the operational features and detailed optical and electrical test results for the new AMOLED WUXGA resolution microdisplay.

  7. Generalized Nonlinear Chirp Scaling Algorithm for High-Resolution Highly Squint SAR Imaging.

    Science.gov (United States)

    Yi, Tianzhu; He, Zhihua; He, Feng; Dong, Zhen; Wu, Manqing

    2017-11-07

    This paper presents a modified approach for high-resolution, highly squint synthetic aperture radar (SAR) data processing. Several nonlinear chirp scaling (NLCS) algorithms have been proposed to solve the azimuth variance of the frequency modulation rates that are caused by the linear range walk correction (LRWC). However, the azimuth depth of focusing (ADOF) is not handled well by these algorithms. The generalized nonlinear chirp scaling (GNLCS) algorithm that is proposed in this paper uses the method of series reverse (MSR) to improve the ADOF and focusing precision. It also introduces a high order processing kernel to avoid the range block processing. Simulation results show that the GNLCS algorithm can enlarge the ADOF and focusing precision for high-resolution highly squint SAR data.

  8. Generalized Nonlinear Chirp Scaling Algorithm for High-Resolution Highly Squint SAR Imaging

    Directory of Open Access Journals (Sweden)

    Tianzhu Yi

    2017-11-01

    Full Text Available This paper presents a modified approach for high-resolution, highly squint synthetic aperture radar (SAR data processing. Several nonlinear chirp scaling (NLCS algorithms have been proposed to solve the azimuth variance of the frequency modulation rates that are caused by the linear range walk correction (LRWC. However, the azimuth depth of focusing (ADOF is not handled well by these algorithms. The generalized nonlinear chirp scaling (GNLCS algorithm that is proposed in this paper uses the method of series reverse (MSR to improve the ADOF and focusing precision. It also introduces a high order processing kernel to avoid the range block processing. Simulation results show that the GNLCS algorithm can enlarge the ADOF and focusing precision for high-resolution highly squint SAR data.

  9. Human enamel structure studied by high resolution electron microscopy

    International Nuclear Information System (INIS)

    Wen, S.L.

    1989-01-01

    Human enamel structural features are characterized by high resolution electron microscopy. The human enamel consists of polycrystals with a structure similar to Ca10(PO4)6(OH)2. This article describes the structural features of human enamel crystal at atomic and nanometer level. Besides the structural description, a great number of high resolution images are included. Research into the carious process in human enamel is very important for human beings. This article firstly describes the initiation of caries in enamel crystal at atomic and unit-cell level and secondly describes the further steps of caries with structural and chemical demineralization. The demineralization in fact, is the origin of caries in human enamel. The remineralization of carious areas in human enamel has drawn more and more attention as its potential application is realized. This process has been revealed by high resolution electron microscopy in detail in this article. On the other hand, the radiation effects on the structure of human enamel are also characterized by high resolution electron microscopy. In order to reveal this phenomenon clearly, a great number of electron micrographs have been shown, and a physical mechanism is proposed. 26 references

  10. Refinement procedure for the image alignment in high-resolution electron tomography

    International Nuclear Information System (INIS)

    Houben, L.; Bar Sadan, M.

    2011-01-01

    High-resolution electron tomography from a tilt series of transmission electron microscopy images requires an accurate image alignment procedure in order to maximise the resolution of the tomogram. This is the case in particular for ultra-high resolution where even very small misalignments between individual images can dramatically reduce the fidelity of the resultant reconstruction. A tomographic-reconstruction based and marker-free method is proposed, which uses an iterative optimisation of the tomogram resolution. The method utilises a search algorithm that maximises the contrast in tomogram sub-volumes. Unlike conventional cross-correlation analysis it provides the required correlation over a large tilt angle separation and guarantees a consistent alignment of images for the full range of object tilt angles. An assessment based on experimental reconstructions shows that the marker-free procedure is competitive to the reference of marker-based procedures at lower resolution and yields sub-pixel accuracy even for simulated high-resolution data. -- Highlights: → Alignment procedure for electron tomography based on iterative tomogram contrast optimisation. → Marker-free, independent of object, little user interaction. → Accuracy competitive with fiducial marker methods and suited for high-resolution tomography.

  11. High resolution backscattering instruments

    International Nuclear Information System (INIS)

    Coldea, R.

    2001-01-01

    The principle of operation of indirect-geometry time-of-flight spectrometers are presented, including the IRIS at the ISIS spallation neutron source. The key features that make those types of spectrometers ideally suited for low-energy spectroscopy are: high energy resolution over a wide dynamic range, and simultaneous measurement over a large momentum transfer range provided by the wide angular detector coverage. To exemplify these features are discussed of single-crystal experiments of the spin dynamics in the two-dimensional frustrated quantum magnet Cs 2 CuCl 4 . (R.P.)

  12. Using Adobe Acrobat to create high-resolution line art images.

    Science.gov (United States)

    Woo, Hyoun Sik; Lee, Jeong Min

    2009-08-01

    The purpose of this article is to introduce a method for using Adobe Acrobat to make high-resolution and high-quality line art images. High-resolution and high-quality line art images for radiology journal submission can be generated using Adobe Acrobat as a steppingstone, and the customized PDF conversion settings can be used for converting hybrid images, including both bitmap and vector components.

  13. High-resolution axial MR imaging of tibial stress injuries

    Directory of Open Access Journals (Sweden)

    Mammoto Takeo

    2012-05-01

    Full Text Available Abstract Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries.

  14. High-resolution axial MR imaging of tibial stress injuries

    Science.gov (United States)

    2012-01-01

    Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries. PMID:22574840

  15. High-resolution esophageal pressure topography for esophageal motility disorders

    OpenAIRE

    Hashem Fakhre Yaseri; Gholamreza Hamsi; Tayeb Ramim

    2016-01-01

    Background: High-resolution manometer (HRM) of the esophagus has become the main diagnostic test in the evaluation of esophageal motility disorders. The development of high-resolution manometry catheters and software displays of manometry recordings in color-coded pressure plots have changed the diagnostic assessment of esophageal disease. The first step of the Chicago classification described abnormal esophagogastric junction deglutitive relaxation. The latest classification system, proposed...

  16. Quantitation of Acrylamide in Foods by High-Resolution Mass Spectrometry

    NARCIS (Netherlands)

    Troise, A.D.; Fogliano, Vincenzo

    2016-01-01

    The use of liquid chromatography high-resolution mass spectrometry (LC-HRMS) and direct analysis real-time high-resolution mass spectrometry (DART-HRMS) defines a new scenario in the analysis of thermal-induced toxicants, such as acrylamide. Several factors contribute to the definition of the

  17. Diagnosis of Cervical Abortion by TransvaginaI Color Doppler Sonography : A Case Report

    International Nuclear Information System (INIS)

    Lee, Eun Ju; Ryu, Hee Sug; Ji, Hoon; Suh, Jung Ho

    1995-01-01

    Cervical abortion is a spontaneous abortion of an intrauterine pregnancy into the cervical canal where the abortus is retained by a closed external os, causing distension of the cervical canal. Cervical abortion should be distinguished from the cervical pregnancy. We present a case of cervical abortion diagnosed preoperatively by transvaginal sonography and color doppler imaging, and treated by dilatation and curettage. Charateristic transvaginal sonographic findings and identification of subtrophoblastic blood flow by color doppler imaging could allow differentiation of the cevical aborition from the cervical pregnancy

  18. High-spin research with HERA [High Energy-Resolution Array

    International Nuclear Information System (INIS)

    Diamond, R.M.

    1987-06-01

    The topic of this report is high spin research with the High Energy Resolution Array (HERA) at Lawrence Berkeley Laboratory. This is a 21 Ge detector system, the first with bismuth germanate (BGO) Compton suppression. The array is described briefly and some of the results obtained during the past year using this detector facility are discussed. Two types of studies are described: observation of superdeformation in the light Nd isotopes, and rotational damping at high spin and excitation energy in the continuum gamma ray spectrum

  19. Ultra high resolution soft x-ray tomography

    International Nuclear Information System (INIS)

    Haddad, W.S.; Trebes, J.E.; Goodman, D.M.

    1995-01-01

    Ultra high resolution three dimensional images of a microscopic test object were made with soft x-rays using a scanning transmission x-ray microscope. The test object consisted of two different patterns of gold bars on silicon nitride windows that were separated by ∼5μm. A series of nine 2-D images of the object were recorded at angles between -50 to +55 degrees with respect to the beam axis. The projections were then combined tomographically to form a 3-D image by means of an algebraic reconstruction technique (ART) algorithm. A transverse resolution of ∼1000 Angstrom was observed. Artifacts in the reconstruction limited the overall depth resolution to ∼6000 Angstrom, however some features were clearly reconstructed with a depth resolution of ∼1000 Angstrom. A specially modified ART algorithm and a constrained conjugate gradient (CCG) code were also developed as improvements over the standard ART algorithm. Both of these methods made significant improvements in the overall depth resolution bringing it down to ∼1200 Angstrom overall. Preliminary projection data sets were also recorded with both dry and re-hydrated human sperm cells over a similar angular range

  20. Ultra high resolution soft x-ray tomography

    International Nuclear Information System (INIS)

    Haddad, W.S.; Trebes, J.E.; Goodman, D.M.; Lee, H.R.; McNulty, I.; Zalensky, A.O.

    1995-01-01

    Ultra high resolution three dimensional images of a microscopic test object were made with soft x-rays using a scanning transmission x-ray microscope. The test object consisted of two different patterns of gold bars on silicon nitride windows that were separated by ∼5 microm. A series of nine 2-D images of the object were recorded at angles between -50 to +55 degrees with respect to the beam axis. The projections were then combined tomographically to form a 3-D image by means of an algebraic reconstruction technique (ART) algorithm. A transverse resolution of ∼ 1,000 angstrom was observed. Artifacts in the reconstruction limited the overall depth resolution to ∼ 6,000 angstrom, however some features were clearly reconstructed with a depth resolution of ∼ 1,000 angstrom. A specially modified ART algorithm and a constrained conjugate gradient (CCG) code were also developed as improvements over the standard ART algorithm. Both of these methods made significant improvements in the overall depth resolution, bringing it down to ∼ 1,200 angstrom overall. Preliminary projection data sets were also recorded with both dry and re-hydrated human sperm cells over a similar angular range

  1. High-resolution 3D imaging of polymerized photonic crystals by lab-based x-ray nanotomography with 50-nm resolution

    Science.gov (United States)

    Yin, Leilei; Chen, Ying-Chieh; Gelb, Jeff; Stevenson, Darren M.; Braun, Paul A.

    2010-09-01

    High resolution x-ray computed tomography is a powerful non-destructive 3-D imaging method. It can offer superior resolution on objects that are opaque or low contrast for optical microscopy. Synchrotron based x-ray computed tomography systems have been available for scientific research, but remain difficult to access for broader users. This work introduces a lab-based high-resolution x-ray nanotomography system with 50nm resolution in absorption and Zernike phase contrast modes. Using this system, we have demonstrated high quality 3-D images of polymerized photonic crystals which have been analyzed for band gap structures. The isotropic volumetric data shows excellent consistency with other characterization results.

  2. High-resolution nuclear magnetic resonance studies of proteins.

    Science.gov (United States)

    Jonas, Jiri

    2002-03-25

    The combination of advanced high-resolution nuclear magnetic resonance (NMR) techniques with high-pressure capability represents a powerful experimental tool in studies of protein folding. This review is organized as follows: after a general introduction of high-pressure, high-resolution NMR spectroscopy of proteins, the experimental part deals with instrumentation. The main section of the review is devoted to NMR studies of reversible pressure unfolding of proteins with special emphasis on pressure-assisted cold denaturation and the detection of folding intermediates. Recent studies investigating local perturbations in proteins and the experiments following the effects of point mutations on pressure stability of proteins are also discussed. Ribonuclease A, lysozyme, ubiquitin, apomyoglobin, alpha-lactalbumin and troponin C were the model proteins investigated.

  3. High-resolution CT of the lungs: Anatomic-pathologic correlation

    International Nuclear Information System (INIS)

    Stein, M.G.; Webb, W.R.; Finkbeiner, W.; Gamsu, G.

    1986-01-01

    The interpretation of thin-section (1.5-mm), high-resolution CT scans of the lungs has been limited by lack of direct radiologic and pathologic correlation. The author scanned fresh inflated isolated lungs from ten healthy and five diseased subjects using thin-section, high-resolution techniques. The lungs were then fixed by inflation with endobronchial Formalin. Gough sections (1 mm thick) were obtained at the same levels as the CT scans. In healthy subjects, secondary lobules were identified by the presence of visible interlobular septa and central arterioles. In some patients with disease, septal thickening was visible. In patients with honeycombing cystic areas of destroyed lung were seen, along with areas of fibrosis. Emphysema was well evaluated. Thin-section, high-resolution CT can define lung architecture and may resolve mild changes of the interstitium

  4. Transvaginal sonographic findings of the ectopic pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Soon Ae; Youn, Chang Seon; Han, Sei Yul; Cho, Joo Youn; Chang, Sang Sik; Cha, Kwang Yul; Cha, Kyung Sub [Cha Women' s Hospital, Sungnam (Korea, Republic of)

    1989-08-15

    Transvaginal(TV) sonography uses high-frequency transducer and allows access to the uterus and adnexa, provides better resolution and more accurate diagnosis of ectopic pregnancy. To determine the value and the utility of TV sonography for a suspected ectopic pregnancy, we studied 56 women during 4 months from January to April 1989. Of 56 patients 46 had an surgically confirmed ectopic pregnancy, 5 had not an ectopic pregnancy and 5 had not follow up. TV sonography provides definite sonographic diagnosis of ectopic pregnancy including an extrauterine gestational sac 34 cases(74%), extrauterine embryo 9 caes(19.7%), hematosalpinx 10 cases(21.7%). Overall adnexal mass was detected in 38 cases(82.6%) at initial TV sonography and in 44 cases(95.6%) at follow up TV sonography. Additional findings were uterine decidual reaction 19 cases(41.3%), pseudo G-sac 4 cases(8.7%), cul-de-sac fluid 42 cases(91.2%). Follow-up TV sonography showed newly developed or growing adnexal mass in 8 among 9 cases. False positive 5 cases were two ovarian cysts, one incomplete abortion, two parametrial thickening due to previous ectopic pregnancy and salpingectomy. TV sonography may improve the govality of patient management by early diagnosis and early surgical treatment, so may preserve fertility. In conclusion, we may suggest that TV sonography is an integral part of diagnostic modality in suspected ectopic pregnancy.

  5. Transvaginal sonographic findings of the ectopic pregnancy

    International Nuclear Information System (INIS)

    Jun, Soon Ae; Youn, Chang Seon; Han, Sei Yul; Cho, Joo Youn; Chang, Sang Sik; Cha, Kwang Yul; Cha, Kyung Sub

    1989-01-01

    Transvaginal(TV) sonography uses high-frequency transducer and allows access to the uterus and adnexa, provides better resolution and more accurate diagnosis of ectopic pregnancy. To determine the value and the utility of TV sonography for a suspected ectopic pregnancy, we studied 56 women during 4 months from January to April 1989. Of 56 patients 46 had an surgically confirmed ectopic pregnancy, 5 had not an ectopic pregnancy and 5 had not follow up. TV sonography provides definite sonographic diagnosis of ectopic pregnancy including an extrauterine gestational sac 34 cases(74%), extrauterine embryo 9 caes(19.7%), hematosalpinx 10 cases(21.7%). Overall adnexal mass was detected in 38 cases(82.6%) at initial TV sonography and in 44 cases(95.6%) at follow up TV sonography. Additional findings were uterine decidual reaction 19 cases(41.3%), pseudo G-sac 4 cases(8.7%), cul-de-sac fluid 42 cases(91.2%). Follow-up TV sonography showed newly developed or growing adnexal mass in 8 among 9 cases. False positive 5 cases were two ovarian cysts, one incomplete abortion, two parametrial thickening due to previous ectopic pregnancy and salpingectomy. TV sonography may improve the govality of patient management by early diagnosis and early surgical treatment, so may preserve fertility. In conclusion, we may suggest that TV sonography is an integral part of diagnostic modality in suspected ectopic pregnancy

  6. High-resolution x-ray imaging using a structured scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Hormozan, Yashar, E-mail: hormozan@kth.se; Sychugov, Ilya; Linnros, Jan [Materials and Nano Physics, School of Information and Communication Technology, KTH Royal Institute of Technology, Electrum 229, Kista, Stockholm SE-16440 (Sweden)

    2016-02-15

    Purpose: In this study, the authors introduce a new generation of finely structured scintillators with a very high spatial resolution (a few micrometers) compared to conventional scintillators, yet maintaining a thick absorbing layer for improved detectivity. Methods: Their concept is based on a 2D array of high aspect ratio pores which are fabricated by ICP etching, with spacings (pitches) of a few micrometers, on silicon and oxidation of the pore walls. The pores were subsequently filled by melting of powdered CsI(Tl), as the scintillating agent. In order to couple the secondary emitted photons of the back of the scintillator array to a CCD device, having a larger pixel size than the pore pitch, an open optical microscope with adjustable magnification was designed and implemented. By imaging a sharp edge, the authors were able to calculate the modulation transfer function (MTF) of this finely structured scintillator. Results: The x-ray images of individually resolved pores suggest that they have been almost uniformly filled, and the MTF measurements show the feasibility of a few microns spatial resolution imaging, as set by the scintillator pore size. Compared to existing techniques utilizing CsI needles as a structured scintillator, their results imply an almost sevenfold improvement in resolution. Finally, high resolution images, taken by their detector, are presented. Conclusions: The presented work successfully shows the functionality of their detector concept for high resolution imaging and further fabrication developments are most likely to result in higher quantum efficiencies.

  7. Science with High Spatial Resolution Far-Infrared Data

    Science.gov (United States)

    Terebey, Susan (Editor); Mazzarella, Joseph M. (Editor)

    1994-01-01

    The goal of this workshop was to discuss new science and techniques relevant to high spatial resolution processing of far-infrared data, with particular focus on high resolution processing of IRAS data. Users of the maximum correlation method, maximum entropy, and other resolution enhancement algorithms applicable to far-infrared data gathered at the Infrared Processing and Analysis Center (IPAC) for two days in June 1993 to compare techniques and discuss new results. During a special session on the third day, interested astronomers were introduced to IRAS HIRES processing, which is IPAC's implementation of the maximum correlation method to the IRAS data. Topics discussed during the workshop included: (1) image reconstruction; (2) random noise; (3) imagery; (4) interacting galaxies; (5) spiral galaxies; (6) galactic dust and elliptical galaxies; (7) star formation in Seyfert galaxies; (8) wavelet analysis; and (9) supernova remnants.

  8. Textural Segmentation of High-Resolution Sidescan Sonar Images

    National Research Council Canada - National Science Library

    Kalcic, Maria; Bibee, Dale

    1995-01-01

    .... The high resolution of the 455 kHz sonar imagery also provides much information about the surficial bottom sediments, however their acoustic scattering properties are not well understood at high frequencies...

  9. High-resolution computed tomography findings in pulmonary Langerhans cell histiocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Rosana Souza [Universidade Federal do Rio de Janeiro (HUCFF/UFRJ), RJ (Brazil). Hospital Universitario Clementino Fraga Filho. Unit of Radiology; Capone, Domenico; Ferreira Neto, Armando Leao [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil)

    2011-07-15

    Objective: The present study was aimed at characterizing main lung changes observed in pulmonary Langerhans cell histiocytosis by means of high-resolution computed tomography. Materials and Methods: High-resolution computed tomography findings in eight patients with proven disease diagnosed by open lung biopsy, immunohistochemistry studies and/or extrapulmonary manifestations were retrospectively evaluated. Results: Small rounded, thin-walled cystic lesions were observed in the lung of all the patients. Nodules with predominantly peripheral distribution over the lung parenchyma were observed in 75% of the patients. The lesions were diffusely distributed, predominantly in the upper and middle lung fields in all of the cases, but involvement of costophrenic angles was observed in 25% of the patients. Conclusion: Comparative analysis of high-resolution computed tomography and chest radiography findings demonstrated that thinwalled cysts and small nodules cannot be satisfactorily evaluated by conventional radiography. Because of its capacity to detect and characterize lung cysts and nodules, high-resolution computed tomography increases the probability of diagnosing pulmonary Langerhans cell histiocytosis. (author)

  10. Limits of the values of thermography in the diagnosis of malignomas of the thyroid - compared with scintigraphy and sonography

    International Nuclear Information System (INIS)

    Kaick, G. van

    1976-01-01

    In 250 patients suffering from various diseases of the thyroid, infrared thermography was tried out in addition to the common methods of examination such as scintiscanning, ultrasonic examination, and puncture with fine needles. These examinations were carried out using the camera videosystem made by Messrs. Rank. The thermopictures consist of 20,000 dots and are produced at a rate of 45 pictures per second. The measurements were made after exposing the bare throat to the constant room temperature of 19 0 for 15 minutes for adaptation. The results of the test indicate that most of the malignant growths on the thyroid can be detected by clinical diagnosis alone. The combination of cold scintiscanning, solid sonography, and thermography will probably enable a better and more specific diagnosis. Thermography and sonography alone are not suitable as screening methods for diagnosing malignant growths in the thyroid. (GSE) [de

  11. A Forward-Looking High-Resolution GPR System

    National Research Council Canada - National Science Library

    Kositsky, Joel; Milanfar, Peyman

    1999-01-01

    A high-resolution ground penetrating radar (GPR) system was designed to help define the optimal radar parameters needed for the efficient standoff detection of buried and surface-laid antitank mines...

  12. Accelerated high-resolution photoacoustic tomography via compressed sensing

    Science.gov (United States)

    Arridge, Simon; Beard, Paul; Betcke, Marta; Cox, Ben; Huynh, Nam; Lucka, Felix; Ogunlade, Olumide; Zhang, Edward

    2016-12-01

    Current 3D photoacoustic tomography (PAT) systems offer either high image quality or high frame rates but are not able to deliver high spatial and temporal resolution simultaneously, which limits their ability to image dynamic processes in living tissue (4D PAT). A particular example is the planar Fabry-Pérot (FP) photoacoustic scanner, which yields high-resolution 3D images but takes several minutes to sequentially map the incident photoacoustic field on the 2D sensor plane, point-by-point. However, as the spatio-temporal complexity of many absorbing tissue structures is rather low, the data recorded in such a conventional, regularly sampled fashion is often highly redundant. We demonstrate that combining model-based, variational image reconstruction methods using spatial sparsity constraints with the development of novel PAT acquisition systems capable of sub-sampling the acoustic wave field can dramatically increase the acquisition speed while maintaining a good spatial resolution: first, we describe and model two general spatial sub-sampling schemes. Then, we discuss how to implement them using the FP interferometer and demonstrate the potential of these novel compressed sensing PAT devices through simulated data from a realistic numerical phantom and through measured data from a dynamic experimental phantom as well as from in vivo experiments. Our results show that images with good spatial resolution and contrast can be obtained from highly sub-sampled PAT data if variational image reconstruction techniques that describe the tissues structures with suitable sparsity-constraints are used. In particular, we examine the use of total variation (TV) regularization enhanced by Bregman iterations. These novel reconstruction strategies offer new opportunities to dramatically increase the acquisition speed of photoacoustic scanners that employ point-by-point sequential scanning as well as reducing the channel count of parallelized schemes that use detector arrays.

  13. A Very High Spatial Resolution Detector for Small Animal PET

    International Nuclear Information System (INIS)

    Kanai Shah, M.S.

    2007-01-01

    Positron Emission Tomography (PET) is an in vivo analog of autoradiography and has the potential to become a powerful new tool in imaging biological processes in small laboratory animals. PET imaging of small animals can provide unique information that can help in advancement of human disease models as well as drug development. Clinical PET scanners used for human imaging are bulky, expensive and do not have adequate spatial resolution for small animal studies. Hence, dedicated, low cost instruments are required for conducting small animal studies with higher spatial resolution than what is currently achieved with clinical as well as dedicated small animal PET scanners. The goal of the proposed project is to investigate a new all solid-state detector design for small animal PET imaging. Exceptionally high spatial resolution, good timing resolution, and excellent energy resolution are expected from the proposed detector design. The Phase I project was aimed at demonstrating the feasibility of producing high performance solid-state detectors that provide high sensitivity, spatial resolution, and timing characteristics. Energy resolution characteristics of the new detector were also investigated. The goal of the Phase II project is to advance the promising solid-state detector technology for small animal PET and determine its full potential. Detectors modules will be built and characterized and finally, a bench-top small animal PET system will be assembled and evaluated

  14. Strengthening IAEA safeguards using high-resolution commercial satellite imagery

    International Nuclear Information System (INIS)

    Zhang Hui

    2001-01-01

    Full text: In May 1997, the IAEA Board of Governors adopted the Additional Safeguards Protocol to improve its ability to detect the undeclared production of fissile material. This new strengthened safeguards system has opened the door for the IAEA to use of all types of information, including the potential use of commercial satellite imagery. We have therefore been investigating the feasibility of strengthening IAEA safeguards using commercial satellite imagery. Based on our analysis on a number of one-meter resolution IKONOS satellite images of military nuclear production facilities at nuclear states including Russia, China, India, Pakistan and Israel, we found that the new high-resolution commercial satellite imagery would play a new and valuable role in strengthening IAEA safeguards. Since 1999, images with a resolution of one meter have been available commercially from Space Imaging's IKONOS satellite. One-meter images from other companies are expected to enter the market soon. Although still an order of magnitude less capable than military imaging satellites, the capabilities of these new high-resolution commercial satellites are good enough to detect and identify the major visible characteristics of nuclear production facilities and sites. Unlike the classified spy satellite photos limited to few countries, the commercial satellite imagery is commercially available to anyone who wants to purchase it. Therefore, the new commercial satellite open a new chance that each state, international organizations, and non-governmental groups could use the commercial images to play a more proactive role in monitoring the nuclear activities in related countries and verifying the compliance of non-proliferation agreements. This could help galvanize support for intensified efforts to slow the pace of nuclear proliferation. To produce fissile materials (plutonium and highly enriched uranium) for weapons, a country would operate dedicated plutonium-production reactors and the

  15. Processing method for high resolution monochromator

    International Nuclear Information System (INIS)

    Kiriyama, Koji; Mitsui, Takaya

    2006-12-01

    A processing method for high resolution monochromator (HRM) has been developed at Japanese Atomic Energy Agency/Quantum Beam Science Directorate/Synchrotron Radiation Research unit at SPring-8. For manufacturing a HRM, a sophisticated slicing machine and X-ray diffractometer have been installed for shaping a crystal ingot and orienting precisely the surface of a crystal ingot, respectively. The specification of the slicing machine is following; Maximum size of a diamond blade is φ 350mm in diameter, φ 38.1mm in the spindle diameter, and 2mm in thickness. A large crystal such as an ingot with 100mm in diameter, 200mm in length can be cut. Thin crystal samples such as a wafer can be also cut using by another sample holder. Working distance of a main shaft with the direction perpendicular to working table in the machine is 350mm at maximum. Smallest resolution of the main shaft with directions of front-and-back and top-and-bottom are 0.001mm read by a digital encoder. 2mm/min can set for cutting samples in the forward direction. For orienting crystal faces relative to the blade direction adjustment, a one-circle goniometer and 2-circle segment are equipped on the working table in the machine. A rotation and a tilt of the stage can be done by manual operation. Digital encoder in a turn stage is furnished and has angle resolution of less than 0.01 degrees. In addition, a hand drill as a supporting device for detailed processing of crystal is prepared. Then, an ideal crystal face can be cut from crystal samples within an accuracy of about 0.01 degrees. By installation of these devices, a high energy resolution monochromator crystal for inelastic x-ray scattering and a beam collimator are got in hand and are expected to be used for nanotechnology studies. (author)

  16. High-resolution coded-aperture design for compressive X-ray tomography using low resolution detectors

    Science.gov (United States)

    Mojica, Edson; Pertuz, Said; Arguello, Henry

    2017-12-01

    One of the main challenges in Computed Tomography (CT) is obtaining accurate reconstructions of the imaged object while keeping a low radiation dose in the acquisition process. In order to solve this problem, several researchers have proposed the use of compressed sensing for reducing the amount of measurements required to perform CT. This paper tackles the problem of designing high-resolution coded apertures for compressed sensing computed tomography. In contrast to previous approaches, we aim at designing apertures to be used with low-resolution detectors in order to achieve super-resolution. The proposed method iteratively improves random coded apertures using a gradient descent algorithm subject to constraints in the coherence and homogeneity of the compressive sensing matrix induced by the coded aperture. Experiments with different test sets show consistent results for different transmittances, number of shots and super-resolution factors.

  17. Refinement procedure for the image alignment in high-resolution electron tomography.

    Science.gov (United States)

    Houben, L; Bar Sadan, M

    2011-01-01

    High-resolution electron tomography from a tilt series of transmission electron microscopy images requires an accurate image alignment procedure in order to maximise the resolution of the tomogram. This is the case in particular for ultra-high resolution where even very small misalignments between individual images can dramatically reduce the fidelity of the resultant reconstruction. A tomographic-reconstruction based and marker-free method is proposed, which uses an iterative optimisation of the tomogram resolution. The method utilises a search algorithm that maximises the contrast in tomogram sub-volumes. Unlike conventional cross-correlation analysis it provides the required correlation over a large tilt angle separation and guarantees a consistent alignment of images for the full range of object tilt angles. An assessment based on experimental reconstructions shows that the marker-free procedure is competitive to the reference of marker-based procedures at lower resolution and yields sub-pixel accuracy even for simulated high-resolution data. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Towards high resolution polarisation analysis using double polarisation and ellipsoidal analysers

    CERN Document Server

    Martin-Y-Marero, D

    2002-01-01

    Classical polarisation analysis methods lack the combination of high resolution and high count rate necessary to cope with the demand of modern condensed-matter experiments. In this work, we present a method to achieve high resolution polarisation analysis based on a double polarisation system. Coupling this method with an ellipsoidal wavelength analyser, a high count rate can be achieved whilst delivering a resolution of around 10 mu eV. This method is ideally suited to pulsed sources, although it can be adapted to continuous sources as well. (orig.)

  19. Sonography of scrotal trauma

    International Nuclear Information System (INIS)

    Rao, Meka Srinivasa; Arjun, Kalyanpur

    2012-01-01

    The purpose of this article is to depict the spectrum of scrotal injuries in blunt trauma. Scrotal injuries are not very common and are mostly due to blunt trauma from direct injury, sports injuries or motor vehicle accidents. To minimize complications and ensure testicular salvage, rapid and accurate diagnosis is necessary. High-resolution USG is the investigation of choice, as it is readily available, accurate and has been seen to improve outcomes. An understanding of and familiarity with the sonographic appearance of scrotal injuries on the part of the radiologist/sonographer is therefore of key importance

  20. Sonography of scrotal trauma

    Directory of Open Access Journals (Sweden)

    Meka Srinivasa Rao

    2012-01-01

    Full Text Available The purpose of this article is to depict the spectrum of scrotal injuries in blunt trauma. Scrotal injuries are not very common and are mostly due to blunt trauma from direct injury, sports injuries or motor vehicle accidents. To minimize complications and ensure testicular salvage, rapid and accurate diagnosis is necessary. High-resolution USG is the investigation of choice, as it is readily available, accurate and has been seen to improve outcomes. An understanding of and familiarity with the sonographic appearance of scrotal injuries on the part of the radiologist/sonographer is therefore of key importance.

  1. Sonography and dynamic scintigraphy with 99mTc-DTPA in children with nephrotic syndrome

    International Nuclear Information System (INIS)

    Bliznakova, D.; Klisarove, A.

    2000-01-01

    The aim of the study is to assay the clinical application of kidney sonography and dynamic scintigraphy with 99m Tc-DTPA in children presenting nephrotic syndrome. A total of 32 children (mean age 9.5±1.2) are covered by the study, with the most important laboratory investigations being performed. All patients undergo abdominal sonography and dynamic kidney scintigraphy following iv administration of 100 μC/kg 99m Tc-DTPA, and glomerular filtration clarence (GFR) measured by the method of full and empty syringe activity. The functional curves are also shown. In children with primary nephrotic syndrome the sonographic imaging reveals enlarged kidney size and enhanced sonogeneity of parenchyma in the first stage. In patients with secondary nephrotic syndrome increased kidney size is likewise observed with enhanced sonogeneity of parenchyma in second stage and unclear visualization of pyramids. In children with idiopathic nephrotic syndrome the scintigraphic data confirm the enlarged kidneys with moderately increased values of GFR. In the mixed forms of nephrotic syndrome the kidneys preserve their moderate enlargement against the background of heterogeneous GFR values. In 5 patients the functional curves show kidney excretion impairment. The study confirms that sonographic imaging correlates well with the dynamic scintigraphic 99m Tc-DTPA imaging in children with nephrotic syndrome. The functional curves and GFR values promote accurate diagnosing and monitoring of the dynamic pathological processes. (author)

  2. Ultra-high resolution HLA genotyping and allele discovery by highly multiplexed cDNA amplicon pyrosequencing

    Directory of Open Access Journals (Sweden)

    Lank Simon M

    2012-08-01

    Full Text Available Abstract Background High-resolution HLA genotyping is a critical diagnostic and research assay. Current methods rarely achieve unambiguous high-resolution typing without making population-specific frequency inferences due to a lack of locus coverage and difficulty in exon-phase matching. Achieving high-resolution typing is also becoming more challenging with traditional methods as the database of known HLA alleles increases. Results We designed a cDNA amplicon-based pyrosequencing method to capture 94% of the HLA class I open-reading-frame with only two amplicons per sample, and an analogous method for class II HLA genes, with a primary focus on sequencing the DRB loci. We present a novel Galaxy server-based analysis workflow for determining genotype. During assay validation, we performed two GS Junior sequencing runs to determine the accuracy of the HLA class I amplicons and DRB amplicon at different levels of multiplexing. When 116 amplicons were multiplexed, we unambiguously resolved 99%of class I alleles to four- or six-digit resolution, as well as 100% unambiguous DRB calls. The second experiment, with 271 multiplexed amplicons, missed some alleles, but generated high-resolution, concordant typing for 93% of class I alleles, and 96% for DRB1 alleles. In a third, preliminary experiment we attempted to sequence novel amplicons for other class II loci with mixed success. Conclusions The presented assay is higher-throughput and higher-resolution than existing HLA genotyping methods, and suitable for allele discovery or large cohort sampling. The validated class I and DRB primers successfully generated unambiguously high-resolution genotypes, while further work is needed to validate additional class II genotyping amplicons.

  3. Transistor reset preamplifier for high-rate high-resolution spectroscopy

    International Nuclear Information System (INIS)

    Landis, D.A.; Cork, C.P.; Madden, N.W.; Goulding, F.S.

    1981-10-01

    Pulsed transistor reset of high resolution charge sensitive preamplifiers used in cooled semiconductor spectrometers can sometimes have an advantage over pulsed light reset systems. Several versions of transistor reset spectrometers using both silicon and germanium detectors have been built. This paper discusses the advantages of the transistor reset system and illustrates several configurations of the packages used for the FET and reset transistor. It also describes the preamplifer circuit and shows the performance of the spectrometer at high rates

  4. [Preoperatory sonography efficiency in paediatric patients with cholelithiasis undergoing laparoscopic cholecystectomy].

    Science.gov (United States)

    Riñón, C; de Mingo, L; Cortés, M J; Ollero, J C; Alvarez, M; Espinosa, R; Rollán, V

    2009-01-01

    Biliary lithiasis is not much frequent in paediatric patients. The manegement of cholelithiasis in patients undergoing laparoscopic cholecystectomy is still controversial. We propose the preoperatory echographic study of the biliary tree 24-48 h before surgery, as the first choice, instead of the intraoperatory cholangiography. We made a retrospective study of 42 patients undergoing laparoscopic cholecystectomy due to symptomatic biliary lithiasis during the last 15 years, with ages between 18 months and 17-years-old (mean age 9,6-years-old) and weight between 11 and 70 kg (mean weight 42 kg) at the moment of surgery. Six of them had haematological illnesses, 17 came to the hospital because of acute abdominal pain, 10 had been studied because of recurrent abdominal pain and 9 had casual diagnoses. Abdominal sonography was performed in all patients 24-48 hours before surgery. Four children were diagnosed of biliary duct lithiasis: two choledocolithiasis and two stones in the cystic duct. One of the cystic stones was extracted in the operating room and the rest resolved spontaneously. One patient presented dilatation of choledocal duct after surgery, without any stones' evidence. Also this patient resolved spontaneously. We had no complications. Biliary lithiasis is not frequent in children, even if it seems to be increasing. A few of these patients will suffer of choledocolithiasis. The intraoperatory exploration of the biliary tree during laparoscopic surgery is technically difficult due the small size of paediatric patients. Cholangiography is not always successful and can produce some important complications as pancreatitis. Preoperative sonography 24-48 hours before surgery is a safe and efficient method for the diagnosis and follow-up of paediatric patients with biliary lithiasis undergoing laparoscopic cholecystectomy. It is safe enough to be performed without intraoperatory cholangiography.

  5. Internal Carotid Artery Hypoplasia: Role of Color-Coded Carotid Duplex Sonography.

    Science.gov (United States)

    Chen, Pei-Ya; Liu, Hung-Yu; Lim, Kun-Eng; Lin, Shinn-Kuang

    2015-10-01

    The purpose of this study was to determine the role of color-coded carotid duplex sonography for diagnosis of internal carotid artery hypoplasia. We retrospectively reviewed 25,000 color-coded carotid duplex sonograms in our neurosonographic database to establish more diagnostic criteria for internal carotid artery hypoplasia. A definitive diagnosis of internal carotid artery hypoplasia was made in 9 patients. Diagnostic findings on color-coded carotid duplex imaging include a long segmental small-caliber lumen (52% diameter) with markedly decreased flow (13% flow volume) in the affected internal carotid artery relative to the contralateral side but without intraluminal lesions. Indirect findings included markedly increased total flow volume (an increase of 133%) in both vertebral arteries, antegrade ipsilateral ophthalmic arterial flow, and a reduced vessel diameter with increased flow resistance in the ipsilateral common carotid artery. Ten patients with distal internal carotid artery dissection showed a similar color-coded duplex pattern, but the reductions in the internal and common carotid artery diameters and increase in collateral flow from the vertebral artery were less prominent than those in hypoplasia. The ipsilateral ophthalmic arterial flow was retrograde in 40% of patients with distal internal carotid artery dissection. In addition, thin-section axial and sagittal computed tomograms of the skull base could show the small diameter of the carotid canal in internal carotid artery hypoplasia and help distinguish hypoplasia from distal internal carotid artery dissection. Color-coded carotid duplex sonography provides important clues for establishing a diagnosis of internal carotid artery hypoplasia. A hypoplastic carotid canal can be shown by thin-section axial and sagittal skull base computed tomography to confirm the final diagnosis. © 2015 by the American Institute of Ultrasound in Medicine.

  6. Constructing a WISE High Resolution Galaxy Atlas

    Science.gov (United States)

    Jarrett, T. H.; Masci, F.; Tsai, C. W.; Petty, S.; Cluver, M.; Assef, Roberto J.; Benford, D.; Blain, A.; Bridge, C.; Donoso, E.; hide

    2012-01-01

    After eight months of continuous observations, the Wide-field Infrared Survey Explorer (WISE) mapped the entire sky at 3.4 micron, 4.6 micron, 12 micron, and 22 micron. We have begun a dedicated WISE High Resolution Galaxy Atlas project to fully characterize large, nearby galaxies and produce a legacy image atlas and source catalog. Here we summarize the deconvolution techniques used to significantly improve the spatial resolution of WISE imaging, specifically designed to study the internal anatomy of nearby galaxies. As a case study, we present results for the galaxy NGC 1566, comparing the WISE enhanced-resolution image processing to that of Spitzer, Galaxy Evolution Explorer, and ground-based imaging. This is the first paper in a two-part series; results for a larger sample of nearby galaxies are presented in the second paper.

  7. High resolution spectroscopy in the microwave and far infrared

    Science.gov (United States)

    Pickett, Herbert M.

    1990-01-01

    High resolution rotational spectroscopy has long been central to remote sensing techniques in atmospheric sciences and astronomy. As such, laboratory measurements must supply the required data to make direct interpretation of data for instruments which sense atmospheres using rotational spectra. Spectral measurements in the microwave and far infrared regions are also very powerful tools when combined with infrared measurements for characterizing the rotational structure of vibrational spectra. In the past decade new techniques were developed which have pushed high resolution spectroscopy into the wavelength region between 25 micrometers and 2 mm. Techniques to be described include: (1) harmonic generation of microwave sources, (2) infrared laser difference frequency generation, (3) laser sideband generation, and (4) ultrahigh resolution interferometers.

  8. Emergency Sonography Aids Diagnostic Accuracy of Torso Injuries: A Study in a Resource Limited Setting

    Directory of Open Access Journals (Sweden)

    Charles Edward Tunuka

    2014-01-01

    Full Text Available Introduction. Clinical evaluation of patients with torso trauma is often a diagnostic challenge. Extended focused assessment with sonography for trauma (EFAST is an emergency ultrasound scan that adds to the evaluation of intrathoracic abdominal and pericardial cavities done in FAST (focused assessment with sonography for trauma. Objective. This study compares EFAST (the index test with the routine standard of care (SoC investigations (the standard reference test for torso trauma injuries. Methods. A cross-sectional descriptive study was conducted over a 3-month period. Eligible patients underwent EFAST scanning and the SoC assessment. The diagnostic accuracy of EFAST was calculated using sensitivity and specificity scores. Results. We recruited 197 patients; the M : F ratio was 5 : 1, with mean age of 27 years (SD 11. The sensitivity of EFAST was 100%, the specificity was 97%, the PPV was 87%, and the NPV was 100%. It took 5 minutes on average to complete an EFAST scan. 168 (85% patients were EFAST-scanned. Most patients (82 (48% were discharged on the same day of hospitalization, while 7 (4% were still at the hospital after two weeks. The mortality rate was 18 (9%. Conclusion. EFAST is a reliable method of diagnosing torso injuries in a resource limited context.

  9. A radiologist's guide to the imaging in the diagnosis and treatment of developmental dysplasia of the hip. Pt. 1. General considerations, physical examination as applied to real-time sonography and radiography

    International Nuclear Information System (INIS)

    Gerscovich, E.O.

    1997-01-01

    Developmental dysplasia of the hip (DDH) has a broad spectrum of presentation with the minor findings resolving spontaneously and the most severe ones resulting in disability, if not diagnosed early in life. Diagnosis in the first few months of life allows conservative treatment with complete resolution in most cases. Suspicion of DDH is based on ethnic, family, and pregnancy history, and on physical examination of the newborn. Imaging assists in the diagnosis and follows the treatment. Different modalities have their own advantages and disadvantages. This article deals with the description of the disease, risk factors, statistics, the physical examination as applied to real-time sonography, and imaging (plain radiography, arthrography, computed tomography, and magnetic resonance imaging). (orig.). With 26 figs., 1 tab

  10. High resolution and high speed positron emission tomography data acquisition

    International Nuclear Information System (INIS)

    Burgiss, S.G.; Byars, L.G.; Jones, W.F.; Casey, M.E.

    1986-01-01

    High resolution positron emission tomography (PET) requires many detectors. Thus, data collection systems for PET must have high data rates, wide data paths, and large memories to histogram the events. This design uses the VMEbus to cost effectively provide these features. It provides for several modes of operation including real time sorting, list mode data storage, and replay of stored list mode data

  11. Vascularity and grey-scale sonographic features of normal cervical lymph nodes: variations with nodal size

    International Nuclear Information System (INIS)

    Ying, Michael; Ahuja, Anil; Brook, Fiona; Metreweli, Constantine

    2001-01-01

    AIM: This study was undertaken to investigate variations in the vascularity and grey-scale sonographic features of cervical lymph nodes with their size. MATERIALS AND METHODS: High resolution grey-scale sonography and power Doppler sonography were performed in 1133 cervical nodes in 109 volunteers who had a sonographic examination of the neck. Standardized parameters were used in power Doppler sonography. RESULTS: About 90% of lymph nodes with a maximum transverse diameter greater than 5 mm showed vascularity and an echogenic hilus. Smaller nodes were less likely to show vascularity and an echogenic hilus. As the size of the lymph nodes increased, the intranodal blood flow velocity increased significantly (P 0.05). CONCLUSIONS: The findings provide a baseline for grey-scale and power Doppler sonography of normal cervical lymph nodes. Sonologists will find varying vascularity and grey-scale appearances when encountering nodes of different sizes. Ying, M. et al. (2001)

  12. Ultra high spatial and temporal resolution breast imaging at 7T.

    Science.gov (United States)

    van de Bank, B L; Voogt, I J; Italiaander, M; Stehouwer, B L; Boer, V O; Luijten, P R; Klomp, D W J

    2013-04-01

    There is a need to obtain higher specificity in the detection of breast lesions using MRI. To address this need, Dynamic Contrast-Enhanced (DCE) MRI has been combined with other structural and functional MRI techniques. Unfortunately, owing to time constraints structural images at ultra-high spatial resolution can generally not be obtained during contrast uptake, whereas the relatively low spatial resolution of functional imaging (e.g. diffusion and perfusion) limits the detection of small lesions. To be able to increase spatial as well as temporal resolution simultaneously, the sensitivity of MR detection needs to increase as well as the ability to effectively accelerate the acquisition. The required gain in signal-to-noise ratio (SNR) can be obtained at 7T, whereas acceleration can be obtained with high-density receiver coil arrays. In this case, morphological imaging can be merged with DCE-MRI, and other functional techniques can be obtained at higher spatial resolution, and with less distortion [e.g. Diffusion Weighted Imaging (DWI)]. To test the feasibility of this concept, we developed a unilateral breast coil for 7T. It comprises a volume optimized dual-channel transmit coil combined with a 30-channel receive array coil. The high density of small coil elements enabled efficient acceleration in any direction to acquire ultra high spatial resolution MRI of close to 0.6 mm isotropic detail within a temporal resolution of 69 s, high spatial resolution MRI of 1.5 mm isotropic within an ultra high temporal resolution of 6.7 s and low distortion DWI at 7T, all validated in phantoms, healthy volunteers and a patient with a lesion in the right breast classified as Breast Imaging Reporting and Data System (BI-RADS) IV. Copyright © 2012 John Wiley & Sons, Ltd.

  13. High-Resolution X-ray Emission and X-ray Absorption Spectroscopy

    NARCIS (Netherlands)

    Groot, F.M.F. de

    2000-01-01

    In this review, high-resolution X-ray emission and X-ray absorption spectroscopy will be discussed. The focus is on the 3d transition-metal systems. To understand high-resolution X-ray emission and reso-nant X-ray emission, it is first necessary to spend some time discussing the X-ray absorption

  14. High-resolution flurescence spectroscopy in immunoanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Grubor, Nenad M. [Iowa State Univ., Ames, IA (United States)

    2005-01-01

    The work presented in this dissertation combines highly sensitive and selective fluorescence line-narrowing spectroscopy (FLNS) detection with various modes of immunoanalytical techniques. It has been shown that FLNS is capable of directly probing molecules immunocomplexed with antibodies, eliminating analytical ambiguities that may arise from interferences that accompany traditional immunochemical techniques. Moreover, the utilization of highly cross-reactive antibodies for highly specific analyte determination has been demonstrated. Finally, they demonstrate the first example of the spectral resolution of diastereomeric analytes based on their interaction with a cross-reactive antibody.

  15. Sonography and computerized tomography in a comparison in renal mass diseases

    International Nuclear Information System (INIS)

    Brommer, M.

    1981-01-01

    One hundred and thirteen patients with renal mass processes were examined sonographically and by computized tomography. The diagnosis was assured in 32 cases histologically, in 40 cases angiographically clinically and by the course and in 41 cases only clinically and by the course resp. by sonographic and computerized tomography control studies. The accuracy of a hit in sonography is smaller compared with computerized tomography with fast image formation. However, due to its relative safety, it is judged as the most useful technique for a first diagnossis of renal masses after ureographic diagnostic of excreta. A diagnostic procedure is proposed in which the number of necessary angiographies and diagnostic sampling surgery can be considerably reduced. (orig.) [de

  16. Development of a high-resolution cavity-beam position monitor

    Directory of Open Access Journals (Sweden)

    Yoichi Inoue

    2008-06-01

    Full Text Available We have developed a high-resolution cavity-beam position monitor (BPM to be used at the focal point of the ATF2, which is a test beam line that is now being built to demonstrate stable orbit control at ∼nanometer resolution. The design of the cavity structure was optimized for the Accelerator Test Facility (ATF beam in various ways. For example, the cavity has a rectangular shape in order to isolate two dipole modes in orthogonal directions, and a relatively thin gap that is less sensitive to trajectory inclination. A two stage homodyne mixer with highly sensitive electronics and phase-sensitive detection was also developed. Two BPM blocks, each containing two cavity BPMs, were installed in the existing ATF beam line using a rigid support frame. After testing the basic characteristics, we measured the resolution using three BPMs. The system demonstrated 8.7 nm position resolution over a dynamic range of 5  μm.

  17. Development of a high-resolution cavity-beam position monitor

    Science.gov (United States)

    Inoue, Yoichi; Hayano, Hitoshi; Honda, Yosuke; Takatomi, Toshikazu; Tauchi, Toshiaki; Urakawa, Junji; Komamiya, Sachio; Nakamura, Tomoya; Sanuki, Tomoyuki; Kim, Eun-San; Shin, Seung-Hwan; Vogel, Vladimir

    2008-06-01

    We have developed a high-resolution cavity-beam position monitor (BPM) to be used at the focal point of the ATF2, which is a test beam line that is now being built to demonstrate stable orbit control at ˜nanometer resolution. The design of the cavity structure was optimized for the Accelerator Test Facility (ATF) beam in various ways. For example, the cavity has a rectangular shape in order to isolate two dipole modes in orthogonal directions, and a relatively thin gap that is less sensitive to trajectory inclination. A two stage homodyne mixer with highly sensitive electronics and phase-sensitive detection was also developed. Two BPM blocks, each containing two cavity BPMs, were installed in the existing ATF beam line using a rigid support frame. After testing the basic characteristics, we measured the resolution using three BPMs. The system demonstrated 8.7 nm position resolution over a dynamic range of 5μm.

  18. Classification of high resolution satellite images

    OpenAIRE

    Karlsson, Anders

    2003-01-01

    In this thesis the Support Vector Machine (SVM)is applied on classification of high resolution satellite images. Sveral different measures for classification, including texture mesasures, 1st order statistics, and simple contextual information were evaluated. Additionnally, the image was segmented, using an enhanced watershed method, in order to improve the classification accuracy.

  19. High-resolution and high-throughput multichannel Fourier transform spectrometer with two-dimensional interferogram warping compensation

    Science.gov (United States)

    Watanabe, A.; Furukawa, H.

    2018-04-01

    The resolution of multichannel Fourier transform (McFT) spectroscopy is insufficient for many applications despite its extreme advantage of high throughput. We propose an improved configuration to realise both performance using a two-dimensional area sensor. For the spectral resolution, we obtained the interferogram of a larger optical path difference by shifting the area sensor without altering any optical components. The non-linear phase error of the interferometer was successfully corrected using a phase-compensation calculation. Warping compensation was also applied to realise a higher throughput to accumulate the signal between vertical pixels. Our approach significantly improved the resolution and signal-to-noise ratio by factors of 1.7 and 34, respectively. This high-resolution and high-sensitivity McFT spectrometer will be useful for detecting weak light signals such as those in non-invasive diagnosis.

  20. A new method for high-resolution characterization of hydraulic conductivity

    Science.gov (United States)

    Liu, Gaisheng; Butler, J.J.; Bohling, Geoffrey C.; Reboulet, Ed; Knobbe, Steve; Hyndman, D.W.

    2009-01-01

    A new probe has been developed for high-resolution characterization of hydraulic conductivity (K) in shallow unconsolidated formations. The probe was recently applied at the Macrodispersion Experiment (MADE) site in Mississippi where K was rapidly characterized at a resolution as fine as 0.015 m, which has not previously been possible. Eleven profiles were obtained with K varying up to 7 orders of magnitude in individual profiles. Currently, high-resolution (0.015-m) profiling has an upper K limit of 10 m/d; lower-resolution (???0.4-m) mode is used in more permeable zones pending modifications. The probe presents a new means to help address unresolved issues of solute transport in heterogeneous systems. Copyright 2009 by the American Geophysical Union.

  1. Evaluation of a High-Resolution Regional Reanalysis for Europe

    Science.gov (United States)

    Ohlwein, C.; Wahl, S.; Keller, J. D.; Bollmeyer, C.

    2014-12-01

    Reanalyses gain more and more importance as a source of meteorological information for many purposes and applications. Several global reanalyses projects (e.g., ERA, MERRA, CSFR, JMA9) produce and verify these data sets to provide time series as long as possible combined with a high data quality. Due to a spatial resolution down to 50-70km and 3-hourly temporal output, they are not suitable for small scale problems (e.g., regional climate assessment, meso-scale NWP verification, input for subsequent models such as river runoff simulations). The implementation of regional reanalyses based on a limited area model along with a data assimilation scheme is able to generate reanalysis data sets with high spatio-temporal resolution. Within the Hans-Ertel-Centre for Weather Research (HErZ), the climate monitoring branch concentrates efforts on the assessment and analysis of regional climate in Germany and Europe. In joint cooperation with DWD (German Meteorological Service), a high-resolution reanalysis system based on the COSMO model has been developed. The regional reanalysis for Europe matches the domain of the CORDEX EURO-11 specifications, albeit at a higher spatial resolution, i.e., 0.055° (6km) instead of 0.11° (12km) and comprises the assimilation of observational data using the existing nudging scheme of COSMO complemented by a special soil moisture analysis with boundary conditions provided by ERA-Interim data. The reanalysis data set covers 6 years (2007-2012) and is currently extended to 16 years. Extensive evaluation of the reanalysis is performed using independent observations with special emphasis on precipitation and high-impact weather situations indicating a better representation of small scale variability. Further, the evaluation shows an added value of the regional reanalysis with respect to the forcing ERA Interim reanalysis and compared to a pure high-resolution dynamical downscaling approach without data assimilation.

  2. High resolution satellite imagery : from spies to pipeline management

    Energy Technology Data Exchange (ETDEWEB)

    Adam, S. [Canadian Geomatic Solutions Ltd., Calgary, AB (Canada); Farrell, M. [TransCanada Transmission, Calgary, AB (Canada)

    2000-07-01

    The launch of Space Imaging's IKONOS satellite in September 1999 has opened the door for corridor applications. The technology has been successfully implemented by TransCanada PipeLines in mapping over 1500 km of their mainline. IKONOS is the world's first commercial high resolution satellite which collects data at 1-meter black/white and 4-meter multi-spectral. Its use is regulated by the U.S. government. It is the best source of high resolution satellite image data. Other sources include the Indian Space Agency's IRS-1 C/D satellite and the Russian SPIN-2 which provides less reliable coverage. In addition, two more high resolution satellites may be launched this year to provide imagery every day of the year. IKONOS scenes as narrow as 5 km can be purchased. TransCanada conducted a pilot study to determine if high resolution satellite imagery is as effective as ortho-photos for identifying population structures within a buffer of TransCanada's east line right-of-way. The study examined three unique segments where residential, commercial, industrial and public features were compared. It was determined that IKONOS imagery is as good as digital ortho-photos for updating structures from low to very high density areas. The satellite imagery was also logistically easier than ortho-photos to acquire. This will be even more evident when the IKONOS image archives begins to grow. 4 tabs., 3 figs.

  3. High resolution radar satellite imagery analysis for safeguards applications

    Energy Technology Data Exchange (ETDEWEB)

    Minet, Christian; Eineder, Michael [German Aerospace Center, Remote Sensing Technology Institute, Department of SAR Signal Processing, Wessling, (Germany); Rezniczek, Arnold [UBA GmbH, Herzogenrath, (Germany); Niemeyer, Irmgard [Forschungszentrum Juelich, Institue of Energy and Climate Research, IEK-6: Nuclear Waste Management and Reactor Safety, Juelich, (Germany)

    2011-12-15

    For monitoring nuclear sites, the use of Synthetic Aperture Radar (SAR) imagery shows essential promises. Unlike optical remote sensing instruments, radar sensors operate under almost all weather conditions and independently of the sunlight, i.e. time of the day. Such technical specifications are required both for continuous and for ad-hoc, timed surveillance tasks. With Cosmo-Skymed, TerraSARX and Radarsat-2, high-resolution SAR imagery with a spatial resolution up to 1m has recently become available. Our work therefore aims to investigate the potential of high-resolution TerraSAR data for nuclear monitoring. This paper focuses on exploiting amplitude of a single acquisition, assessing amplitude changes and phase differences between two acquisitions, and PS-InSAR processing of an image stack.

  4. Effects of display resolution and size on primary diagnosis of chest images using a high-resolution electronic work station

    International Nuclear Information System (INIS)

    Fuhrman, C.R.; Cooperstein, L.A.; Herron, J.; Good, W.F.; Good, B.; Gur, D.; Maitz, G.; Tabor, E.; Hoy, R.J.

    1987-01-01

    To evaluate the acceptability of electronically displayed planar images, the authors have a high-resolution work station. This system utilizes a high-resolution film digitizer (100-micro resolution) interfaced to a mainframe computer and two high-resolution (2,048 X 2,048) display devices (Azuray). In a clinically simulated multiobserver blind study (19 cases and five observers) a prodetermined series of reading sessions is stored on magnetic disk and is transferred to the displays while the preceding set of images is being reviewed. Images can be linearly processed on the fly into 2,000 X 2,000 full resolution, 1,000 X 1,000 minified display, or 1,000 X 1,000 interpolated for full-size display. Results of the study indicate that radiologists accept but do not like significant minification (more than X2), and they rate 2,000 X 2,000 images as having better diagnostic quality than 1,000 X 1,000 images

  5. High-resolution phylogenetic microbial community profiling

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Esther; Coleman-Derr, Devin; Bowman, Brett; Schwientek, Patrick; Clum, Alicia; Copeland, Alex; Ciobanu, Doina; Cheng, Jan-Fang; Gies, Esther; Hallam, Steve; Tringe, Susannah; Woyke, Tanja

    2014-03-17

    The representation of bacterial and archaeal genome sequences is strongly biased towards cultivated organisms, which belong to merely four phylogenetic groups. Functional information and inter-phylum level relationships are still largely underexplored for candidate phyla, which are often referred to as microbial dark matter. Furthermore, a large portion of the 16S rRNA gene records in the GenBank database are labeled as environmental samples and unclassified, which is in part due to low read accuracy, potential chimeric sequences produced during PCR amplifications and the low resolution of short amplicons. In order to improve the phylogenetic classification of novel species and advance our knowledge of the ecosystem function of uncultivated microorganisms, high-throughput full length 16S rRNA gene sequencing methodologies with reduced biases are needed. We evaluated the performance of PacBio single-molecule real-time (SMRT) sequencing in high-resolution phylogenetic microbial community profiling. For this purpose, we compared PacBio and Illumina metagenomic shotgun and 16S rRNA gene sequencing of a mock community as well as of an environmental sample from Sakinaw Lake, British Columbia. Sakinaw Lake is known to contain a large age of microbial species from candidate phyla. Sequencing results show that community structure based on PacBio shotgun and 16S rRNA gene sequences is highly similar in both the mock and the environmental communities. Resolution power and community representation accuracy from SMRT sequencing data appeared to be independent of GC content of microbial genomes and was higher when compared to Illumina-based metagenome shotgun and 16S rRNA gene (iTag) sequences, e.g. full-length sequencing resolved all 23 OTUs in the mock community, while iTags did not resolve closely related species. SMRT sequencing hence offers various potential benefits when characterizing uncharted microbial communities.

  6. [Can TOF MRA replace duplex and Doppler sonography in preoperative assessment of the carotid arteries? A prospective comparison and review of the literature].

    Science.gov (United States)

    Krappel, F A; Bauer, E; Harland, U

    2002-01-01

    To examine the quality and usefulness of time-of-flight MR-angiography and duplex-doppler sonography, respectively, in assessment of the extracranial arteries before cervical spine operations. Patients scheduled for operations of the cervical spine had an MRI plus TOF as well as a duplex and Doppler scan. At the time of the examination the radiologist and the neurologist in charge were blinded for the study. Endpoints were not only the accuracy of the procedures but more so which method improved the preoperative process most. Twenty patients were examined so far. Only in one case did the result differ when a complete occlusion diagnosed sonographically was judged as a severe stenosis on MRA. One patient did not tolerate the MRA for the extra 5 minutes necessary, therefore a contrast-enhanced MRA was performed. MRA eased the preoperative process as imaging of the pathology and the carotids were realised in one step. The costs were slightly higher for MRA than for duplex-doppler sonography. TOF-MRA can replace the duplex-doppler examination in the preoperative assessment of the carotids and has the potential to streamline the preoperative time schedule. Similar to duplex and doppler, in order to be accurate enough the method requires a high degree of expertise from the radiologist.

  7. The utility of focused assessment with sonography for trauma as a triage tool in multiple-casualty incidents during the second Lebanon war.

    Science.gov (United States)

    Beck-Razi, Nira; Fischer, Doron; Michaelson, Moshe; Engel, Ahuva; Gaitini, Diana

    2007-09-01

    The purpose of this study was to evaluate the role of focused assessment with sonography for trauma (FAST) as a triage tool in multiple-casualty incidents (MCIs) for a single international conflict. The charts of 849 casualties that arrived at our level 1 trauma referral center were reviewed. Casualties were initially triaged according to the Injury Severity Score at the emergency department gate. Two-hundred eighty-one physically injured patients, 215 soldiers (76.5%) and 66 civilians (23.5%), were admitted. Focused assessment with sonography for trauma was performed in 102 casualties suspected to have an abdominal injury. Sixty-eight underwent computed tomography (CT); 12 underwent laparotomy; and 28 were kept under clinical observation alone. We compared FAST results against CT, laparotomy, and clinical observation records. Focused assessment with sonography for trauma results were positive in 17 casualties and negative in 85. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of FAST were 75%, 97.6%, 88.2%, 94.1%, and 93.1%, respectively. A strong correlation between FAST and CT results, laparotomy, and clinical observation was obtained (P war conflict-related MCI, FAST enabled immediate triage of casualties to laparotomy, CT, or clinical observation. Because of its moderate sensitivity, a negative FAST result with strong clinical suspicion demands further evaluation, especially in an MCI.

  8. Analysis strategies for high-resolution UHF-fMRI data.

    Science.gov (United States)

    Polimeni, Jonathan R; Renvall, Ville; Zaretskaya, Natalia; Fischl, Bruce

    2018-03-01

    Functional MRI (fMRI) benefits from both increased sensitivity and specificity with increasing magnetic field strength, making it a key application for Ultra-High Field (UHF) MRI scanners. Most UHF-fMRI studies utilize the dramatic increases in sensitivity and specificity to acquire high-resolution data reaching sub-millimeter scales, which enable new classes of experiments to probe the functional organization of the human brain. This review article surveys advanced data analysis strategies developed for high-resolution fMRI at UHF. These include strategies designed to mitigate distortion and artifacts associated with higher fields in ways that attempt to preserve spatial resolution of the fMRI data, as well as recently introduced analysis techniques that are enabled by these extremely high-resolution data. Particular focus is placed on anatomically-informed analyses, including cortical surface-based analysis, which are powerful techniques that can guide each step of the analysis from preprocessing to statistical analysis to interpretation and visualization. New intracortical analysis techniques for laminar and columnar fMRI are also reviewed and discussed. Prospects for single-subject individualized analyses are also presented and discussed. Altogether, there are both specific challenges and opportunities presented by UHF-fMRI, and the use of proper analysis strategies can help these valuable data reach their full potential. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. A High-Resolution Stopwatch for Cents

    Science.gov (United States)

    Gingl, Z.; Kopasz, K.

    2011-01-01

    A very low-cost, easy-to-make stopwatch is presented to support various experiments in mechanics. The high-resolution stopwatch is based on two photodetectors connected directly to the microphone input of a sound card. Dedicated free open-source software has been developed and made available to download. The efficiency is demonstrated by a free…

  10. A radiologist`s guide to the imaging in the diagnosis and treatment of developmental dysplasia of the hip. Pt. 1. General considerations, physical examination as applied to real-time sonography and radiography

    Energy Technology Data Exchange (ETDEWEB)

    Gerscovich, E.O. [Department of Radiology, University of California, Davis Medical Center, 2516 Stockton Blvd., Ticon II Building, Sacramento, CA 95817 (United States)

    1997-07-07

    Developmental dysplasia of the hip (DDH) has a broad spectrum of presentation with the minor findings resolving spontaneously and the most severe ones resulting in disability, if not diagnosed early in life. Diagnosis in the first few months of life allows conservative treatment with complete resolution in most cases. Suspicion of DDH is based on ethnic, family, and pregnancy history, and on physical examination of the newborn. Imaging assists in the diagnosis and follows the treatment. Different modalities have their own advantages and disadvantages. This article deals with the description of the disease, risk factors, statistics, the physical examination as applied to real-time sonography, and imaging (plain radiography, arthrography, computed tomography, and magnetic resonance imaging). (orig.). With 26 figs., 1 tab.

  11. Ring artifact correction for high-resolution micro CT

    International Nuclear Information System (INIS)

    Kyriakou, Yiannis; Prell, Daniel; Kalender, Willi A

    2009-01-01

    In high-resolution micro CT using flat detectors (FD), imperfect or defect detector elements may cause concentric-ring artifacts due to their continuous over- or underestimation of attenuation values, which often disturb image quality. We here present a dedicated image-based ring artifact correction method for high-resolution micro CT, based on median filtering of the reconstructed image and working on a transformed version of the reconstructed images in polar coordinates. This post-processing method reduced ring artifacts in the reconstructed images and improved image quality for phantom and in in vivo scans. Noise and artifacts were reduced both in transversal and in multi-planar reformations along the longitudinal axis. (note)

  12. Digital approach to high-resolution pulse processing for semiconductor detectors

    International Nuclear Information System (INIS)

    Georgiev, A.; Buchner, A.; Gast, W.; Lieder, R.M.

    1992-01-01

    A new design philosophy for processing signals produced by high resolution, large volume semiconductor detectors is described. These detectors, to be used in the next generation of spectrometer arrays for nuclear research (i.e. EUROBALL, etc.), present a set of problems like resolution degradation due to charge trapping and ballistic defect effects, low resolution at a high count rate, poor long term stability, etc. To solve these problems, a new design approach has been developed, including reconstruction of the event charge, providing a pure triangular residual function, and suppressing low frequency noise. 5 refs., 4 figs

  13. Digital approach to high-resolution pulse processing for semiconductor detectors

    Energy Technology Data Exchange (ETDEWEB)

    Georgiev, A [Sofia Univ. (Bulgaria); Buchner, A [Forschungszentrum Rossendorf (Germany); Gast, W; Lieder, R M [Forschungszentrum Juelich GmbH (Germany). Inst. fuer Kernphysik; Stein, J [Target System Electronic GmbH, Solingen, (Germany)

    1992-08-01

    A new design philosophy for processing signals produced by high resolution, large volume semiconductor detectors is described. These detectors, to be used in the next generation of spectrometer arrays for nuclear research (i.e. EUROBALL, etc.), present a set of problems like resolution degradation due to charge trapping and ballistic defect effects, low resolution at a high count rate, poor long term stability, etc. To solve these problems, a new design approach has been developed, including reconstruction of the event charge, providing a pure triangular residual function, and suppressing low frequency noise. 5 refs., 4 figs.

  14. Enhancing GIS Capabilities for High Resolution Earth Science Grids

    Science.gov (United States)

    Koziol, B. W.; Oehmke, R.; Li, P.; O'Kuinghttons, R.; Theurich, G.; DeLuca, C.

    2017-12-01

    Applications for high performance GIS will continue to increase as Earth system models pursue more realistic representations of Earth system processes. Finer spatial resolution model input and output, unstructured or irregular modeling grids, data assimilation, and regional coordinate systems present novel challenges for GIS frameworks operating in the Earth system modeling domain. This presentation provides an overview of two GIS-driven applications that combine high performance software with big geospatial datasets to produce value-added tools for the modeling and geoscientific community. First, a large-scale interpolation experiment using National Hydrography Dataset (NHD) catchments, a high resolution rectilinear CONUS grid, and the Earth System Modeling Framework's (ESMF) conservative interpolation capability will be described. ESMF is a parallel, high-performance software toolkit that provides capabilities (e.g. interpolation) for building and coupling Earth science applications. ESMF is developed primarily by the NOAA Environmental Software Infrastructure and Interoperability (NESII) group. The purpose of this experiment was to test and demonstrate the utility of high performance scientific software in traditional GIS domains. Special attention will be paid to the nuanced requirements for dealing with high resolution, unstructured grids in scientific data formats. Second, a chunked interpolation application using ESMF and OpenClimateGIS (OCGIS) will demonstrate how spatial subsetting can virtually remove computing resource ceilings for very high spatial resolution interpolation operations. OCGIS is a NESII-developed Python software package designed for the geospatial manipulation of high-dimensional scientific datasets. An overview of the data processing workflow, why a chunked approach is required, and how the application could be adapted to meet operational requirements will be discussed here. In addition, we'll provide a general overview of OCGIS

  15. Off ice Hysteroscopy in Patients with Abnormal Uterine Bleeding and Normal Transvaginal Sonography

    Directory of Open Access Journals (Sweden)

    Mojgan Barati

    2008-01-01

    Full Text Available Background: Abnormal uterine bleeding (AUB is one of the most common clinical problemsin gynecology. Transvaginal sonography (TVS and hysteroscopy are two diagnostic methods forpatients with AUB. For most of the patients with AUB, diagnostic hysteroscopy can be done inclinic with minimal discomfort and much lower expense than operative room.Materials and Methods: In our clinical trial study, from March 21, 2005 to March 20, 2007,patients with AUB in Ahwaz Imam Khomayni hospital, after history and physical examinationsunderwent TVS. Of those, 147 patients with normal TVS entered the study and were considered foroutpatient hysteroscopy. Patients with endometrial cavity lesion were scheduled for operation room,and those with empty endometrial cavity aspiration biopsy were done outpatiently. Specimens weresent to pathologist for examination.Results: All the patients were divided into three groups: group 1 or minority was under 30 yearsold (7 women, group 2 was 30-40 years, and group 3 or majority was over 40 years old (96women. 115 patients (78.2% had normal and 32 patients (21.8% had abnormal hysteroscopicresults. 116 patients (78.8% had normal and 31 patients (21.2% had abnormal pathologic results;moreover, cervical canal polyp was the most common lesion hysteroscopically and pathologicallyin all groups.Conclusion: Of 147 patients (100% with AUB and normal TVS, 32 patients (21.8% wereabnormal hysteroscopically. Cervical canal polyps may be missed by transvaginal sonography, butcan be diagnosed by hysteroscopy. In patients with AUB and normal TVS, hysteroscopy can beused as the second step.

  16. Computer simulation of high resolution transmission electron micrographs: theory and analysis

    International Nuclear Information System (INIS)

    Kilaas, R.

    1985-03-01

    Computer simulation of electron micrographs is an invaluable aid in their proper interpretation and in defining optimum conditions for obtaining images experimentally. Since modern instruments are capable of atomic resolution, simulation techniques employing high precision are required. This thesis makes contributions to four specific areas of this field. First, the validity of a new method for simulating high resolution electron microscope images has been critically examined. Second, three different methods for computing scattering amplitudes in High Resolution Transmission Electron Microscopy (HRTEM) have been investigated as to their ability to include upper Laue layer (ULL) interaction. Third, a new method for computing scattering amplitudes in high resolution transmission electron microscopy has been examined. Fourth, the effect of a surface layer of amorphous silicon dioxide on images of crystalline silicon has been investigated for a range of crystal thicknesses varying from zero to 2 1/2 times that of the surface layer

  17. The role of whole body spiral CT in the primary work-up of polytrauma patients - comparison with conventional radiography and abdominal sonography; Die Rolle der Ganzkoerper-Spiral-CT bei der Primaerdiagnostik polytraumatisierter Patienten - Vergleich mit konventioneller Radiographie und Abdomensonographie

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, T.; Schlippenbach, J. von; Wolf, K.J. [Klinik und Poliklinik fuer Radiologie und Nuklearmedizin, Charite - Campus Benjamin Franklin (Germany); Stahel, P.F.; Ertel, W. [Klinik fuer Unfall- und Wiederherstellungschirurgie, Charite - Campus Benjamin Franklin (Germany)

    2004-08-01

    Purpose: To evaluate the role of routine 'whole body spiral CT' in the primary work-up of polytrauma patients for injuries of the thorax, abdomen and spine, and to compare the results with those of conventional radiography of the chest and spine and abdominal ultrasound. Materials and Methods: Fifty consecutive polytrauma patients underwent contrast-enhanced single slice spiral CT (5 mm collimation) from the vertex to the floor of the pelvis as part of the primary work-up after emergency room admission. Overlapping high resolution sections and sagittal reformations of the spine were obtained. Reports of additional chest radiographs (n=43), abdominal ultrasound examinations (n=47) and spine radiographs (n=36) performed in the emergency room were available for retrospective comparison. The 'final diagnoses', which served as the standard of reference, were taken from the patients' records using all information that became available until discharge or death, such as findings from further imaging, surgery and autopsy. Results: CT showed 109 (97%) of 112 thoracic and abdominal soft-tissue injuries. Relevant injuries missed were an early splenic laceration and an early pelvic hematoma, both of which became clinically apparent several hours later. There were 4 false positive CT findings. Conventional chest radiography demonstrated only 20% of thoracic and sonography 22% of abdominal injuries. Chest radiography and sonography produced 2 false-positive findings each. CT showed 66 (87%) of 76 vertebral fractures including all 19 unstable ones. CT missed 5 anterior vertebral body and 5 spinous/transverse process fractures. Conventional radiography found 71% of vertebral fractures including only 50% of the unstable one. (orig.)

  18. The development of high resolution silicon x-ray microcalorimeters

    Science.gov (United States)

    Porter, F. S.; Kelley, R. L.; Kilbourne, C. A.

    2005-12-01

    Recently we have produced x-ray microcalorimeters with resolving powers approaching 2000 at 5.9 keV using a spare XRS microcalorimeter array. We attached 400 um square, 8 um thick HgTe absorbers using a variety of attachment methods to an XRS array and ran the detector array at temperatures between 40 and 60 mK. The best results were for absorbers attached using the standard XRS absorber-pixel thermal isolation scheme utilizing SU8 polymer tubes. In this scenario we achieved a resolution of 3.2 eV FWHM at 5.9 keV. Substituting a silicon spacer for the SU8 tubes also yielded sub-4eV results. In contrast, absorbers attached directly to the thermistor produced significant position dependence and thus degraded resolution. Finally, we tested standard 640um-square XRS detectors at reduced bias power at 50mK and achieved a resolution of 3.7eV, a 50% improvement over the XRS flight instrument. Implanted silicon microcalorimeters are a mature flight-qualified technology that still has a substantial phase space for future development. We will discuss these new high resolution results, the various absorber attachment schemes, planned future improvements, and, finally, their relevance to future high resolution x-ray spectrometers including Constellation-X.

  19. High resolution muon computed tomography at neutrino beam facilities

    International Nuclear Information System (INIS)

    Suerfu, B.; Tully, C.G.

    2016-01-01

    X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pion decay pipe at a neutrino beam facility and what can be achieved for momentum resolution in a muon spectrometer. Such an imaging system can be applied in archaeology, art history, engineering, material identification and whenever there is a need to image inside a transportable object constructed of dense materials

  20. Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes

    International Nuclear Information System (INIS)

    Yang Yongfeng; Dokhale, Purushottam A; Silverman, Robert W; Shah, Kanai S; McClish, Mickel A; Farrell, Richard; Entine, Gerald; Cherry, Simon R

    2006-01-01

    We explore dual-ended read out of LSO arrays with two position sensitive avalanche photodiodes (PSAPDs) as a high resolution, high efficiency depth-encoding detector for PET applications. Flood histograms, energy resolution and depth of interaction (DOI) resolution were measured for unpolished LSO arrays with individual crystal sizes of 1.0, 1.3 and 1.5 mm, and for a polished LSO array with 1.3 mm pixels. The thickness of the crystal arrays was 20 mm. Good flood histograms were obtained for all four arrays, and crystals in all four arrays can be clearly resolved. Although the amplitude of each PSAPD signal decreases as the interaction depth moves further from the PSAPD, the sum of the two PSAPD signals is essentially constant with irradiation depth for all four arrays. The energy resolutions were similar for all four arrays, ranging from 14.7% to 15.4%. A DOI resolution of 3-4 mm (including the width of the irradiation band which is ∼2 mm) was obtained for all the unpolished arrays. The best DOI resolution was achieved with the unpolished 1 mm array (average 3.5 mm). The DOI resolution for the 1.3 mm and 1.5 mm unpolished arrays was 3.7 and 4.0 mm respectively. For the polished array, the DOI resolution was only 16.5 mm. Summing the DOI profiles across all crystals for the 1 mm array only degraded the DOI resolution from 3.5 mm to 3.9 mm, indicating that it may not be necessary to calibrate the DOI response separately for each crystal within an array. The DOI response of individual crystals in the array confirms this finding. These results provide a detailed characterization of the DOI response of these PSAPD-based PET detectors which will be important in the design and calibration of a PET scanner making use of this detector approach

  1. A high resolution x-ray fluorescence spectrometer for near edge absorption studies

    International Nuclear Information System (INIS)

    Stojanoff, V.; Hamalainen, K.; Siddons, D.P.; Hastings, J.B.; Berman, L.E.; Cramer, S.; Smith, G.

    1991-01-01

    A high resolution fluorescence spectrometer using a Johann geometry in a back scattering arrangement was developed. The spectrometer, with a resolution of 0.3 eV at 6.5 keV, combined with an incident beam, with a resolution of 0.7 eV, form the basis of a high resolution instrument for measuring x-ray absorption spectra. The advantages of the instrument are illustrated with the near edge absorption spectrum of dysprosium nitrate. 10 refs., 4 figs

  2. High Frequency High Spectral Resolution Focal Plane Arrays for AtLAST

    Science.gov (United States)

    Baryshev, Andrey

    2018-01-01

    Large collecting area single dish telescope such as ATLAST will be especially effective for medium (R 1000) and high (R 50000) spectral resolution observations. Large focal plane array is a natural solution to increase mapping speed. For medium resolution direct detectors with filter banks (KIDs) and or heterodyne technology can be employed. We will analyze performance limits of comparable KID and SIS focal plane array taking into account quantum limit and high background condition of terrestrial observing site. For large heterodyne focal plane arrays, a high current density AlN junctions open possibility of large instantaneous bandwidth >40%. This and possible multi frequency band FPSs presents a practical challenge for spatial sampling and scanning strategies. We will discuss phase array feeds as a possible solution, including a modular back-end system, which can be shared between KID and SIS based FPA. Finally we will discuss achievable sensitivities and pixel co unts for a high frequency (>500 GHz) FPAs and address main technical challenges: LO distribution, wire counts, bias line multiplexing, and monolithic vs. discrete mixer component integration.

  3. A new omni-directional multi-camera system for high resolution surveillance

    Science.gov (United States)

    Cogal, Omer; Akin, Abdulkadir; Seyid, Kerem; Popovic, Vladan; Schmid, Alexandre; Ott, Beat; Wellig, Peter; Leblebici, Yusuf

    2014-05-01

    Omni-directional high resolution surveillance has a wide application range in defense and security fields. Early systems used for this purpose are based on parabolic mirror or fisheye lens where distortion due to the nature of the optical elements cannot be avoided. Moreover, in such systems, the image resolution is limited to a single image sensor's image resolution. Recently, the Panoptic camera approach that mimics the eyes of flying insects using multiple imagers has been presented. This approach features a novel solution for constructing a spherically arranged wide FOV plenoptic imaging system where the omni-directional image quality is limited by low-end sensors. In this paper, an overview of current Panoptic camera designs is provided. New results for a very-high resolution visible spectrum imaging and recording system inspired from the Panoptic approach are presented. The GigaEye-1 system, with 44 single cameras and 22 FPGAs, is capable of recording omni-directional video in a 360°×100° FOV at 9.5 fps with a resolution over (17,700×4,650) pixels (82.3MP). Real-time video capturing capability is also verified at 30 fps for a resolution over (9,000×2,400) pixels (21.6MP). The next generation system with significantly higher resolution and real-time processing capacity, called GigaEye-2, is currently under development. The important capacity of GigaEye-1 opens the door to various post-processing techniques in surveillance domain such as large perimeter object tracking, very-high resolution depth map estimation and high dynamicrange imaging which are beyond standard stitching and panorama generation methods.

  4. EMODnet High Resolution Seabed Mapping - further developing a high resolution digital bathymetry for European seas

    Science.gov (United States)

    Schaap, D.; Schmitt, T.

    2017-12-01

    Access to marine data is a key issue for the EU Marine Strategy Framework Directive and the EU Marine Knowledge 2020 agenda and includes the European Marine Observation and Data Network (EMODnet) initiative. EMODnet aims at assembling European marine data, data products and metadata from diverse sources in a uniform way. The EMODnet Bathymetry project has developed Digital Terrain Models (DTM) for the European seas. These have been produced from survey and aggregated data sets that are indexed with metadata by adopting the SeaDataNet Catalogue services. SeaDataNet is a network of major oceanographic data centres around the European seas that manage, operate and further develop a pan-European infrastructure for marine and ocean data management. The latest EMODnet Bathymetry DTM release has a grid resolution of 1/8 arcminute and covers all European sea regions. Use has been made of circa 7800 gathered survey datasets and composite DTMs. Catalogues and the EMODnet DTM are published at the dedicated EMODnet Bathymetry portal including a versatile DTM viewing and downloading service. End December 2016 the Bathymetry project has been succeeded by EMODnet High Resolution Seabed Mapping (HRSM). This continues gathering of bathymetric in-situ data sets with extra efforts for near coastal waters and coastal zones. In addition Satellite Derived Bathymetry data are included to fill gaps in coverage of the coastal zones. The extra data and composite DTMs will increase the coverage of the European seas and its coastlines, and provide input for producing an EMODnet DTM with a common resolution of 1/16 arc minutes. The Bathymetry Viewing and Download service will be upgraded to provide a multi-resolution map and including 3D viewing. The higher resolution DTMs will also be used to determine best-estimates of the European coastline for a range of tidal levels (HAT, MHW, MSL, Chart Datum, LAT), thereby making use of a tidal model for Europe. Extra challenges will be `moving to the

  5. High resolution microphotonic needle for endoscopic imaging (Conference Presentation)

    Science.gov (United States)

    Tadayon, Mohammad Amin; Mohanty, Aseema; Roberts, Samantha P.; Barbosa, Felippe; Lipson, Michal

    2017-02-01

    GRIN (Graded index) lens have revolutionized micro endoscopy enabling deep tissue imaging with high resolution. The challenges of traditional GRIN lenses are their large size (when compared with the field of view) and their limited resolution. This is because of the relatively weak NA in standard graded index lenses. Here we introduce a novel micro-needle platform for endoscopy with much higher resolution than traditional GRIN lenses and a FOV that corresponds to the whole cross section of the needle. The platform is based on polymeric (SU-8) waveguide integrated with a microlens micro fabricated on a silicon substrate using a unique molding process. Due to the high index of refraction of the material the NA of the needle is much higher than traditional GRIN lenses. We tested the probe in a fluorescent dye solution (19.6 µM Alexa Flour 647 solution) and measured a numerical aperture of 0.25, focal length of about 175 µm and minimal spot size of about 1.6 µm. We show that the platform can image a sample with the field of view corresponding to the cross sectional area of the waveguide (80x100 µm2). The waveguide size can in principle be modified to vary size of the imaging field of view. This demonstration, combined with our previous work demonstrating our ability to implant the high NA needle in a live animal, shows that the proposed system can be used for deep tissue imaging with very high resolution and high field of view.

  6. Imaging collagen type I fibrillogenesis with high spatiotemporal resolution

    International Nuclear Information System (INIS)

    Stamov, Dimitar R; Stock, Erik; Franz, Clemens M; Jähnke, Torsten; Haschke, Heiko

    2015-01-01

    Fibrillar collagens, such as collagen type I, belong to the most abundant extracellular matrix proteins and they have received much attention over the last five decades due to their large interactome, complex hierarchical structure and high mechanical stability. Nevertheless, the collagen self-assembly process is still incompletely understood. Determining the real-time kinetics of collagen type I formation is therefore pivotal for better understanding of collagen type I structure and function, but visualising the dynamic self-assembly process of collagen I on the molecular scale requires imaging techniques offering high spatiotemporal resolution. Fast and high-speed scanning atomic force microscopes (AFM) provide the means to study such processes on the timescale of seconds under near-physiological conditions. In this study we have applied fast AFM tip scanning to study the assembly kinetics of fibrillar collagen type I nanomatrices with a temporal resolution reaching eight seconds for a frame size of 500 nm. By modifying the buffer composition and pH value, the kinetics of collagen fibrillogenesis can be adjusted for optimal analysis by fast AFM scanning. We furthermore show that amplitude-modulation imaging can be successfully applied to extract additional structural information from collagen samples even at high scan rates. Fast AFM scanning with controlled amplitude modulation therefore provides a versatile platform for studying dynamic collagen self-assembly processes at high resolution. - Highlights: • Continuous non-invasive time-lapse investigation of collagen I fibrillogenesis in situ. • Imaging of collagen I self-assembly with high spatiotemporal resolution. • Application of setpoint modulation to study the hierarchical structure of collagen I. • Observing real-time formation of the D-banding pattern in collagen I

  7. Imaging collagen type I fibrillogenesis with high spatiotemporal resolution

    Energy Technology Data Exchange (ETDEWEB)

    Stamov, Dimitar R, E-mail: stamov@jpk.com [JPK Instruments AG, Bouchéstrasse 12, 12435 Berlin (Germany); Stock, Erik [JPK Instruments AG, Bouchéstrasse 12, 12435 Berlin (Germany); Franz, Clemens M [DFG-Center for Functional Nanostructures (CFN), Karlsruhe Institute of Technology (KIT), Wolfgang-Gaede-Strasse 1a, 76131 Karlsruhe (Germany); Jähnke, Torsten; Haschke, Heiko [JPK Instruments AG, Bouchéstrasse 12, 12435 Berlin (Germany)

    2015-02-15

    Fibrillar collagens, such as collagen type I, belong to the most abundant extracellular matrix proteins and they have received much attention over the last five decades due to their large interactome, complex hierarchical structure and high mechanical stability. Nevertheless, the collagen self-assembly process is still incompletely understood. Determining the real-time kinetics of collagen type I formation is therefore pivotal for better understanding of collagen type I structure and function, but visualising the dynamic self-assembly process of collagen I on the molecular scale requires imaging techniques offering high spatiotemporal resolution. Fast and high-speed scanning atomic force microscopes (AFM) provide the means to study such processes on the timescale of seconds under near-physiological conditions. In this study we have applied fast AFM tip scanning to study the assembly kinetics of fibrillar collagen type I nanomatrices with a temporal resolution reaching eight seconds for a frame size of 500 nm. By modifying the buffer composition and pH value, the kinetics of collagen fibrillogenesis can be adjusted for optimal analysis by fast AFM scanning. We furthermore show that amplitude-modulation imaging can be successfully applied to extract additional structural information from collagen samples even at high scan rates. Fast AFM scanning with controlled amplitude modulation therefore provides a versatile platform for studying dynamic collagen self-assembly processes at high resolution. - Highlights: • Continuous non-invasive time-lapse investigation of collagen I fibrillogenesis in situ. • Imaging of collagen I self-assembly with high spatiotemporal resolution. • Application of setpoint modulation to study the hierarchical structure of collagen I. • Observing real-time formation of the D-banding pattern in collagen I.

  8. Advances in the early diagnosis of congenital hip dysplasia by real-time sonography

    Energy Technology Data Exchange (ETDEWEB)

    Brockmann, W.P.; Wilmsdorf, H.v.; Weh, L.; Korn, U.

    1984-05-01

    Twenty-four infants and children aged five days to three years had their hips examined by ultrasound, and in 17 the findings were compared with the radiographic appearances. Real-time sonography, because of its flexibility, is a suitable screening method for the early diagnosis of hip dysplasia. It has the typical characteristics of a screening method: so far there have been no false negative findings. False positive results are rare, but cannot be completely excluded. The patients examined so far were mostly abnormal, and a final assessment of false positive findings will have to await larger clinical material, including normals. 6 figs.

  9. Demographics of new Undergraduate Medical Imaging and Medical Sonography degree students at CQUniversity, Australia

    International Nuclear Information System (INIS)

    Spuur, Kelly M.; Falconi, Caroline L.; Cowling, Cynthia M.; Bowman, Anita L.; Maroney, Maria A.

    2012-01-01

    Aim: To report the student demographics of the inaugural intake into the Bachelor of Medical Imaging and Bachelor of Medical Sonography/Graduate Diploma of Medical Sonography at CQUniversity, Mackay, Australia. Method: Surveys were distributed to students enrolled in the course MEDI11001 Fundamentals of the Imaging Professions; this course is common to both cohorts in Term 1 of the programs. All students enrolled at the time of the survey were present to participate in the survey. Participation was voluntary. Descriptive statistics were developed from responses and thematic analysis applied to open-ended questions. Results: A total of 44 students were enrolled in the programs. The most common place of residence on enrolment was within 40 km of the Mackay campus (16/36.4%); mature age students (30/68.2%); live on campus in the purpose built residences (18/40.9%) and were influenced by the location of the programs in Mackay to enrol (27/61.2%), with the primary justification for this being that the programs were offered close to home. The university website was identified as the primary source of information regarding the programs (15/34.1%) followed by family and friends (11/25%). The programs were first preference for 31 students (70.5%). The majority (23/52.3%) undertakes some type of paid work. Conclusion: Both programs have attracted a diverse student cohort. The majority of students were mature age students from outside of the area local to the Mackay campus of CQUniversity.

  10. Sonography of acute appendicitis in pregnant women: diagnostic accuracy by the stage of gestation

    International Nuclear Information System (INIS)

    Kim, Sam Soo; Lee, Sang Wook; Rho, Myung Ho

    2004-01-01

    To evaluate the diagnostic accuracy of a diagnosis of acute appendicitis in pregnant women according to the trimester. A retrospective review was performed on 103 pregnant women who underwent sonography with clinically suspected acute appendicitis. The sonographic technique used involved either the graded compression or a non-compression method. All the sonograms were obtained after changing the patient's position and identifying the diseased appendix. The criterion for a sonographic diagnosis of acute appendicitis was the visualization of a non-compressible appendix with a maximal diameter ≥ 6 mm. The sonographic findings were correlated with the surgical findings and clinical follow-up. Acute appendicitis was confirmed by both the surgical and pathological findings in 48 out of 103 pregnant women. Ultrasound established the diagnosis in 34 of the 48 patients with proven appendicitis. There were false-positives in 2 patients and false-negatives in 14 patients. Among the 55 patients who had a normal appendix, 30 patients improved at the clinical follow-up and 25 patients had other intra-abdominal disorders. The diagnostic accuracy of the ultrasound was 94% in the first trimester, 81% in the second trimester, and 76% in the third trimester. The overall accuracy was found to be 84%, with a 71% sensitivity and a 96% specificity. No significant difference was found in the diagnostic accuracy of the ultrasound according to the trimester in which the acute appendicitis occurred. Therefore, regardless of the stage of gestation, sonography is a valuable procedure for diagnosing acute appendicitis

  11. High-resolution fiber-optic microendoscopy for in situ cellular imaging.

    Science.gov (United States)

    Pierce, Mark; Yu, Dihua; Richards-Kortum, Rebecca

    2011-01-11

    Many biological and clinical studies require the longitudinal study and analysis of morphology and function with cellular level resolution. Traditionally, multiple experiments are run in parallel, with individual samples removed from the study at sequential time points for evaluation by light microscopy. Several intravital techniques have been developed, with confocal, multiphoton, and second harmonic microscopy all demonstrating their ability to be used for imaging in situ. With these systems, however, the required infrastructure is complex and expensive, involving scanning laser systems and complex light sources. Here we present a protocol for the design and assembly of a high-resolution microendoscope which can be built in a day using off-the-shelf components for under US$5,000. The platform offers flexibility in terms of image resolution, field-of-view, and operating wavelength, and we describe how these parameters can be easily modified to meet the specific needs of the end user. We and others have explored the use of the high-resolution microendoscope (HRME) in in vitro cell culture, in excised and living animal tissues, and in human tissues in vivo. Users have reported the use of several different fluorescent contrast agents, including proflavine, benzoporphyrin-derivative monoacid ring A (BPD-MA), and fluoroscein, all of which have received full, or investigational approval from the FDA for use in human subjects. High-resolution microendoscopy, in the form described here, may appeal to a wide range of researchers working in the basic and clinical sciences. The technique offers an effective and economical approach which complements traditional benchtop microscopy, by enabling the user to perform high-resolution, longitudinal imaging in situ.

  12. Compressed sensing cine imaging with high spatial or high temporal resolution for analysis of left ventricular function.

    Science.gov (United States)

    Goebel, Juliane; Nensa, Felix; Schemuth, Haemi P; Maderwald, Stefan; Gratz, Marcel; Quick, Harald H; Schlosser, Thomas; Nassenstein, Kai

    2016-08-01

    To assess two compressed sensing cine magnetic resonance imaging (MRI) sequences with high spatial or high temporal resolution in comparison to a reference steady-state free precession cine (SSFP) sequence for reliable quantification of left ventricular (LV) volumes. LV short axis stacks of two compressed sensing breath-hold cine sequences with high spatial resolution (SPARSE-SENSE HS: temporal resolution: 40 msec, in-plane resolution: 1.0 × 1.0 mm(2) ) and high temporal resolution (SPARSE-SENSE HT: temporal resolution: 11 msec, in-plane resolution: 1.7 × 1.7 mm(2) ) and of a reference cine SSFP sequence (standard SSFP: temporal resolution: 40 msec, in-plane resolution: 1.7 × 1.7 mm(2) ) were acquired in 16 healthy volunteers on a 1.5T MR system. LV parameters were analyzed semiautomatically twice by one reader and once by a second reader. The volumetric agreement between sequences was analyzed using paired t-test, Bland-Altman plots, and Passing-Bablock regression. Small differences were observed between standard SSFP and SPARSE-SENSE HS for stroke volume (SV; -7 ± 11 ml; P = 0.024), ejection fraction (EF; -2 ± 3%; P = 0.019), and myocardial mass (9 ± 9 g; P = 0.001), but not for end-diastolic volume (EDV; P = 0.079) and end-systolic volume (ESV; P = 0.266). No significant differences were observed between standard SSFP and SPARSE-SENSE HT regarding EDV (P = 0.956), SV (P = 0.088), and EF (P = 0.103), but for ESV (3 ± 5 ml; P = 0.039) and myocardial mass (8 ± 10 ml; P = 0.007). Bland-Altman analysis showed good agreement between the sequences (maximum bias ≤ -8%). Two compressed sensing cine sequences, one with high spatial resolution and one with high temporal resolution, showed good agreement with standard SSFP for LV volume assessment. J. Magn. Reson. Imaging 2016;44:366-374. © 2016 Wiley Periodicals, Inc.

  13. Small part ultrasound in childhood and adolescence

    Energy Technology Data Exchange (ETDEWEB)

    Wunsch, R., E-mail: R.Wunsch@kinderklinik-datteln.de [Department of Pediatric Radiology, Vestic Children' s Hospital Datteln, University of Witten/Herdecke, Dr.-Friedrich-Steiner-Strasse 5, D-45711 Datteln (Germany); Rohden, L. von, E-mail: l.vonrohden@gmx.de [Department of Pediatric Radiology, Otto-von-Guericke-University Magdeburg, Klinik f. Radiologie und Nuklearmedizin – Kinderradiologie, Leipziger Straße 44, D-39120 Magdeburg (Germany); Cleaveland, R. [Department of Pediatric Radiology, Vestic Children' s Hospital Datteln, University of Witten/Herdecke, Dr.-Friedrich-Steiner-Strasse 5, D-45711 Datteln (Germany); Aumann, V., E-mail: volker.aumann@med.ovgu.de [Department of Pediatric Haematology and Oncology, Otto-von-Guericke-University Magdeburg, Universitätskinderklinik (H 10), Pädiatrische Hämatologie und Onkologie, Leipziger Straße 44, D-39120 Magdeburg (Germany)

    2014-09-15

    Small-part sonography refers to the display of small, near-surface structures using high-frequency linear array transducers. Traditional applications for small part ultrasound imaging include visualization and differential diagnostic evaluation in unclear superficial bodily structures with solid, liquid and mixed texture, as well as similar structures in nearly superficial organs such as the thyroid glands and the testes. Furthermore indications in the head and neck regions are the assessment of the outer CSF spaces in infants, the sonography of the orbit, the sonography of the walls of the large neck vessels, the visualization of superficially situated lymph nodes and neoplasms. Clinical evidence concludes that sonography, having of all imaging modalities the highest spatial resolution in the millimeter- and micrometer range (100–1000 μm), can be considered the best suited technique for examining superficial pathological formations and near-surface organs. In addition, it delivers important information about characteristic, often pathognomonic tissue architecture in pathological processes.

  14. Small part ultrasound in childhood and adolescence

    International Nuclear Information System (INIS)

    Wunsch, R.; Rohden, L. von; Cleaveland, R.; Aumann, V.

    2014-01-01

    Small-part sonography refers to the display of small, near-surface structures using high-frequency linear array transducers. Traditional applications for small part ultrasound imaging include visualization and differential diagnostic evaluation in unclear superficial bodily structures with solid, liquid and mixed texture, as well as similar structures in nearly superficial organs such as the thyroid glands and the testes. Furthermore indications in the head and neck regions are the assessment of the outer CSF spaces in infants, the sonography of the orbit, the sonography of the walls of the large neck vessels, the visualization of superficially situated lymph nodes and neoplasms. Clinical evidence concludes that sonography, having of all imaging modalities the highest spatial resolution in the millimeter- and micrometer range (100–1000 μm), can be considered the best suited technique for examining superficial pathological formations and near-surface organs. In addition, it delivers important information about characteristic, often pathognomonic tissue architecture in pathological processes

  15. Transcranial brainstem sonography as a diagnostic tool for amyotrophic lateral sclerosis.

    Science.gov (United States)

    Prell, Tino; Schenk, Annekathrin; Witte, Otto W; Grosskreutz, Julian; Günther, Albrecht

    2014-06-01

    Diagnosing amyotrophic lateral sclerosis (ALS) can be difficult, particularly in the early stage of disease; therefore, we evaluated the use of transcranial stem sonography (TCS) to improve early detection of the disease. In this cross-sectional study, 94 patients with sporadic ALS and 46 age- and gender-matched healthy controls were evaluated by TCS according to a standardized protocol used to diagnose Parkinson's disease. Approximately half (48%) of the patients with ALS showed a clear (> 0.25 cm(2)) mesencephalic hyperechogenic structure, 20% showed a possible (laterally. In conclusion, although the neuropathological correlation to hyperechogenicity remains unclear, TCS is an easy, feasible and reproducible technique that could serve as an additional diagnostic tool and as a surrogate biomarker in ALS.

  16. 1024 matrix image reconstruction: usefulness in high resolution chest CT

    International Nuclear Information System (INIS)

    Jeong, Sun Young; Chung, Myung Jin; Chong, Se Min; Sung, Yon Mi; Lee, Kyung Soo

    2006-01-01

    We tried to evaluate whether high resolution chest CT with a 1,024 matrix has a significant advantage in image quality compared to a 512 matrix. Each set of 512 and 1024 matrix high resolution chest CT scans with both 0.625 mm and 1.25 mm slice thickness were obtained from 26 patients. Seventy locations that contained twenty-four low density lesions without sharp boundary such as emphysema, and forty-six sharp linear densities such as linear fibrosis were selected; these were randomly displayed on a five mega pixel LCD monitor. All the images were masked for information concerning the matrix size and slice thickness. Two chest radiologists scored the image quality of each ar rowed lesion as follows: (1) undistinguishable, (2) poorly distinguishable, (3) fairly distinguishable, (4) well visible and (5) excellently visible. The scores were compared from the aspects of matrix size, slice thickness and the different observers by using ANOVA tests. The average and standard deviation of image quality were 3.09 (± .92) for the 0.625 mm x 512 matrix, 3.16 (± .84) for the 0.625 mm x 1024 matrix, 2.49 (± 1.02) for the 1.25 mm x 512 matrix, and 2.35 (± 1.02) for the 1.25 mm x 1024 matrix, respectively. The image quality on both matrices of the high resolution chest CT scans with a 0.625 mm slice thickness was significantly better than that on the 1.25 mm slice thickness (ρ < 0.001). However, the image quality on the 1024 matrix high resolution chest CT scans was not significantly different from that on the 512 matrix high resolution chest CT scans (ρ = 0.678). The interobserver variation between the two observers was not significant (ρ = 0.691). We think that 1024 matrix image reconstruction for high resolution chest CT may not be clinical useful

  17. Study on a high resolution positron emission tomography scanner for brain study

    International Nuclear Information System (INIS)

    Nohara, N.; Tomitani, T.; Yamamoto, M.; Murayama, H.; Tanaka, E.

    1990-01-01

    The spatial resolution of positron emission tomography (PET) scanners is usually limited by the finite size of crystals such as bismuth germanate (BGO). To attain high resolution as well as high sensitivity, it is essential to use a large number of small BGO crystals arranged in close-packing on circular rings. In developing high resolution PET scanners, however, there are two physical factors limiting the spatial resolution. One is the finite range of positrons before annihilation and the other the deviation from 180 degrees of annihilation photons. The effect of the factors on the spatial resolution has been evaluated for positron-emitting sources as a function of detector ring radius. A high resolution PET scanner has been developed for brain study, aiming to have spatial resolutions as high as less than 4-mm FWHM in tomographic plane and less than 6-mm FWHM in axial direction at the detector ring center. For the goal of the high resolutions a multi-segment type of photomultiplier tubes has been specially designed and developed, which allows one tube to be directly coupled by four BGO crystals. The scanner consists of five detector rings of 47-cm in diameter, using all 1200 BGO crystals each measuring 5 mm x 12 mm x 30 mm. The scanner provides simultaneous 9 images by combination of in-plane and cross-plane, offering a 24-cm dia. x7.4-cm field-of-view. Physical performance of the scanner was investigated. At the ring center, the spatial resolution in the tomographic plane was measured to be 3.5-mm FWHM. The axial resolution was measured to be 5.7-mm FWHM for in-plane and 5.3-mm FWHM for cross-plane. Sensitivity for a 20-cm dia. uniform source was measured to be 9.5 kcps/μCi/ml for in-plane and 15.3 kcps/μCi/ml for cross-plane. (J.P.N.)

  18. Beam-transport system for high-resolution heavy-ion spectroscopy

    International Nuclear Information System (INIS)

    Roussel, P.; Kashy, E.

    1980-01-01

    A method is given to adjust a beam-transport system to the requirements of high-energy resolution heavy-ion spectroscopy. The results of a test experiment performed on a MP tandem with a 12 C beam are shown. A drastic improvement in energy resolution is obtained for a kinematical factor K=1/p dp/dtheta=0.12 [fr

  19. Workshop on high-resolution, large-acceptance spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Zeidman, B. (ed.)

    1981-01-01

    The purpose of the Workshop on High-Resolution, Large-Acceptance Spectrometers was to provide a means for exchange of information among those actively engaged in the design and construction of these new spectrometers. Thirty-seven papers were prepared for the data base.

  20. Very high-resolution regional climate simulations over Scandinavia-present climate

    DEFF Research Database (Denmark)

    Christensen, Ole B.; Christensen, Jens H.; Machenhauer, Bennert

    1998-01-01

    realistically simulated. It is found in particular that in mountainous regions the high-resolution simulation shows improvements in the simulation of hydrologically relevant fields such as runoff and snow cover. Also, the distribution of precipitation on different intensity classes is most realistically...... on a high-density station network for the Scandinavian countries compiled for the present study. The simulated runoff is compared with observed data from Sweden extracted from a Swedish climatological atlas. These runoff data indicate that the precipitation analyses are underestimating the true...... simulated in the high-resolution simulation. It does, however, inherit certain large-scale systematic errors from the driving GCM. In many cases these errors increase with increasing resolution. Model verification of near-surface temperature and precipitation is made using a new gridded climatology based...

  1. Digital signal processors for cryogenic high-resolution x-ray detector readout

    International Nuclear Information System (INIS)

    Friedrich, Stephan; Drury, Owen B.; Bechstein, Sylke; Hennig, Wolfgang; Momayezi, Michael

    2003-01-01

    We are developing fast digital signal processors (DSPs) to read out superconducting high-resolution X-ray detectors with on-line pulse processing. For superconducting tunnel junction (STJ) detector read-out, the DSPs offer online filtering, rise time discrimination and pile-up rejection. Compared to analog pulse processing, DSP readout somewhat degrades the detector resolution, but improves the spectral purity of the detector response. We discuss DSP performance with our 9-channel STJ array for synchrotron-based high-resolution X-ray spectroscopy. (author)

  2. High spatial resolution CT image reconstruction using parallel computing

    International Nuclear Information System (INIS)

    Yin Yin; Liu Li; Sun Gongxing

    2003-01-01

    Using the PC cluster system with 16 dual CPU nodes, we accelerate the FBP and OR-OSEM reconstruction of high spatial resolution image (2048 x 2048). Based on the number of projections, we rewrite the reconstruction algorithms into parallel format and dispatch the tasks to each CPU. By parallel computing, the speedup factor is roughly equal to the number of CPUs, which can be up to about 25 times when 25 CPUs used. This technique is very suitable for real-time high spatial resolution CT image reconstruction. (authors)

  3. High resolution and simultaneous monitoring of airborne radionuclides

    International Nuclear Information System (INIS)

    Abe, T.; Yamaguchi, Y.; Muguntha Manikandan, N.; Komura, K.

    2005-01-01

    By using 11 extremely low background Ge detectors at Ogoya Underground Laboratory, it became possible to investigate temporal variations of airborne 212 Pb (T 1/2 =10.6 h) along with 210 Pb and 7 Be with order of magnitude higher time resolution. Then, we have measured airborne nuclides at three monitoring points, (1) roof of our laboratory (LLRL; 40 m ASL), (2) Shinshiku Plateau (640 m ASL) located about 8 km from LLRL as a comparison of vertical distribution, and (3) Hegura Island (10 m ASL) at about 50 km from Wajima located north of Noto Peninsula facing on the Sea of Japan (about 180 km to the north-northeast of LLRL), to investigate influence of Asian continent. Airborne nuclides were collected by high volume air samplers at intervals of a few hours at either two or three points simultaneously. In the same manner, high resolution monitoring was carried out also at the time of passage of typhoon and cold front. In this study, we observed drastic temporal variations of airborne radionuclides and correlations of multiple monitoring points. The results indicate that high resolution and simultaneous monitoring is very useful to understand dynamic state of variations of airborne nuclides due to short and long-term air-mass movement. (author)

  4. High-resolution multimodal clinical multiphoton tomography of skin

    Science.gov (United States)

    König, Karsten

    2011-03-01

    This review focuses on multimodal multiphoton tomography based on near infrared femtosecond lasers. Clinical multiphoton tomographs for 3D high-resolution in vivo imaging have been placed into the market several years ago. The second generation of this Prism-Award winning High-Tech skin imaging tool (MPTflex) was introduced in 2010. The same year, the world's first clinical CARS studies have been performed with a hybrid multimodal multiphoton tomograph. In particular, non-fluorescent lipids and water as well as mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen has been imaged with submicron resolution in patients suffering from psoriasis. Further multimodal approaches include the combination of multiphoton tomographs with low-resolution wide-field systems such as ultrasound, optoacoustical, OCT, and dermoscopy systems. Multiphoton tomographs are currently employed in Australia, Japan, the US, and in several European countries for early diagnosis of skin cancer, optimization of treatment strategies, and cosmetic research including long-term testing of sunscreen nanoparticles as well as anti-aging products.

  5. Comparison of sonography and magnetic resonance imaging for the diagnosis of partial tears of finger extensor tendons in rheumatoid arthritis

    NARCIS (Netherlands)

    Swen, W. A.; Jacobs, J. W.; Hubach, P. C.; Klasens, J. H.; Algra, P. R.; Bijlsma, J. W.

    2000-01-01

    Finger extensor tenosynovitis in rheumatoid arthritis (RA) may lead to partial and eventually to complete tendon tears. The aim of this study was to investigate the diagnostic value of sonography (SG) and/or magnetic resonance imaging (MRI) to visualize partial tendon tears. Twenty-one RA patients

  6. 3D Super-Resolution Motion-Corrected MRI: Validation of Fetal Posterior Fossa Measurements.

    Science.gov (United States)

    Pier, Danielle B; Gholipour, Ali; Afacan, Onur; Velasco-Annis, Clemente; Clancy, Sean; Kapur, Kush; Estroff, Judy A; Warfield, Simon K

    2016-09-01

    Current diagnosis of fetal posterior fossa anomalies by sonography and conventional MRI is limited by fetal position, motion, and by two-dimensional (2D), rather than three-dimensional (3D), representation. In this study, we aimed to validate the use of a novel magnetic resonance imaging (MRI) technique, 3D super-resolution motion-corrected MRI, to image the fetal posterior fossa. From a database of pregnant women who received fetal MRIs at our institution, images of 49 normal fetal brains were reconstructed. Six measurements of the cerebellum, vermis, and pons were obtained for all cases on 2D conventional and 3D reconstructed MRI, and the agreement between the two methods was determined using concordance correlation coefficients. Concordance of axial and coronal measurements of the transcerebellar diameter was also assessed within each method. Between the two methods, the concordance of measurements was high for all six structures (P fetal motion and orthogonal slice acquisition. This technique will facilitate further study of fetal abnormalities of the posterior fossa. Copyright © 2016 by the American Society of Neuroimaging.

  7. Integrated High Resolution Monitoring of Mediterranean vegetation

    Science.gov (United States)

    Cesaraccio, Carla; Piga, Alessandra; Ventura, Andrea; Arca, Angelo; Duce, Pierpaolo; Mereu, Simone

    2017-04-01

    The study of the vegetation features in a complex and highly vulnerable ecosystems, such as Mediterranean maquis, leads to the need of using continuous monitoring systems at high spatial and temporal resolution, for a better interpretation of the mechanisms of phenological and eco-physiological processes. Near-surface remote sensing techniques are used to quantify, at high temporal resolution, and with a certain degree of spatial integration, the seasonal variations of the surface optical and radiometric properties. In recent decades, the design and implementation of global monitoring networks involved the use of non-destructive and/or cheaper approaches such as (i) continuous surface fluxes measurement stations, (ii) phenological observation networks, and (iii) measurement of temporal and spatial variations of the vegetation spectral properties. In this work preliminary results from the ECO-SCALE (Integrated High Resolution Monitoring of Mediterranean vegetation) project are reported. The project was manly aimed to develop an integrated system for environmental monitoring based on digital photography, hyperspectral radiometry , and micrometeorological techniques during three years of experimentation (2013-2016) in a Mediterranean site of Italy (Capo Caccia, Alghero). The main results concerned the analysis of chromatic coordinates indices from digital images, to characterized the phenological patterns for typical shrubland species, determining start and duration of the growing season, and the physiological status in relation to different environmental drought conditions; then the seasonal patterns of canopy phenology, was compared to NEE (Net Ecosystem Exchange) patterns, showing similarities. However, maximum values of NEE and ER (Ecosystem respiration), and short term variation, seemed mainly tuned by inter annual pattern of meteorological variables, in particular of temperature recorded in the months preceding the vegetation green-up. Finally, green signals

  8. A multi-channel high-resolution time recorder system

    International Nuclear Information System (INIS)

    Zhang Lingyun; Yang Xiaojun; Song Kezhu; Wang Yanfang

    2004-01-01

    This paper introduces a multi-channel and high-speed time recorder system, which was originally designed to work in the experiments of quantum cryptography research. The novelty of the system is that all the hardware logic is performed by only one FPGA. The system can achieve several desirable features, such as simplicity, high resolution and high processing speed. (authors)

  9. Application of high resolution synchrotron micro-CT radiation in dental implant osseointegration

    DEFF Research Database (Denmark)

    Neldam, Camilla Albeck; Lauridsen, Torsten; Rack, Alexander

    2015-01-01

    The purpose of this study was to describe a refined method using high-resolution synchrotron radiation microtomography (SRmicro-CT) to evaluate osseointegration and peri-implant bone volume fraction after titanium dental implant insertion. SRmicro-CT is considered gold standard evaluating bone...... microarchitecture. Its high resolution, high contrast, and excellent high signal-to-noise-ratio all contribute to the highest spatial resolutions achievable today. Using SRmicro-CT at a voxel size of 5 μm in an experimental goat mandible model, the peri-implant bone volume fraction was found to quickly increase...

  10. An angle encoder for super-high resolution and super-high accuracy using SelfA

    Science.gov (United States)

    Watanabe, Tsukasa; Kon, Masahito; Nabeshima, Nobuo; Taniguchi, Kayoko

    2014-06-01

    Angular measurement technology at high resolution for applications such as in hard disk drive manufacturing machines, precision measurement equipment and aspherical process machines requires a rotary encoder with high accuracy, high resolution and high response speed. However, a rotary encoder has angular deviation factors during operation due to scale error or installation error. It has been assumed to be impossible to achieve accuracy below 0.1″ in angular measurement or control after the installation onto the rotating axis. Self-calibration (Lu and Trumper 2007 CIRP Ann. 56 499; Kim et al 2011 Proc. MacroScale; Probst 2008 Meas. Sci. Technol. 19 015101; Probst et al Meas. Sci. Technol. 9 1059; Tadashi and Makoto 1993 J. Robot. Mechatronics 5 448; Ralf et al 2006 Meas. Sci. Technol. 17 2811) and cross-calibration (Probst et al 1998 Meas. Sci. Technol. 9 1059; Just et al 2009 Precis. Eng. 33 530; Burnashev 2013 Quantum Electron. 43 130) technologies for a rotary encoder have been actively discussed on the basis of the principle of circular closure. This discussion prompted the development of rotary tables which achieve reliable and high accuracy angular verification. We apply these technologies for the development of a rotary encoder not only to meet the requirement of super-high accuracy but also to meet that of super-high resolution. This paper presents the development of an encoder with 221 = 2097 152 resolutions per rotation (360°), that is, corresponding to a 0.62″ signal period, achieved by the combination of a laser rotary encoder supplied by Magnescale Co., Ltd and a self-calibratable encoder (SelfA) supplied by The National Institute of Advanced Industrial Science & Technology (AIST). In addition, this paper introduces the development of a rotary encoder to guarantee ±0.03″ accuracy at any point of the interpolated signal, with respect to the encoder at the minimum resolution of 233, that is, corresponding to a 0.0015″ signal period after

  11. Quantifying and containing the curse of high resolution coronal imaging

    Directory of Open Access Journals (Sweden)

    V. Delouille

    2008-10-01

    Full Text Available Future missions such as Solar Orbiter (SO, InterHelioprobe, or Solar Probe aim at approaching the Sun closer than ever before, with on board some high resolution imagers (HRI having a subsecond cadence and a pixel area of about (80 km2 at the Sun during perihelion. In order to guarantee their scientific success, it is necessary to evaluate if the photon counts available at these resolution and cadence will provide a sufficient signal-to-noise ratio (SNR. For example, if the inhomogeneities in the Quiet Sun emission prevail at higher resolution, one may hope to locally have more photon counts than in the case of a uniform source. It is relevant to quantify how inhomogeneous the quiet corona will be for a pixel pitch that is about 20 times smaller than in the case of SoHO/EIT, and 5 times smaller than TRACE. We perform a first step in this direction by analyzing and characterizing the spatial intermittency of Quiet Sun images thanks to a multifractal analysis. We identify the parameters that specify the scale-invariance behavior. This identification allows next to select a family of multifractal processes, namely the Compound Poisson Cascades, that can synthesize artificial images having some of the scale-invariance properties observed on the recorded images. The prevalence of self-similarity in Quiet Sun coronal images makes it relevant to study the ratio between the SNR present at SoHO/EIT images and in coarsened images. SoHO/EIT images thus play the role of "high resolution" images, whereas the "low-resolution" coarsened images are rebinned so as to simulate a smaller angular resolution and/or a larger distance to the Sun. For a fixed difference in angular resolution and in Spacecraft-Sun distance, we determine the proportion of pixels having a SNR preserved at high resolution given a particular increase in effective area. If scale-invariance continues to prevail at smaller scales, the conclusion reached with SoHO/EIT images can be transposed

  12. A High-resolution Reanalysis for the European CORDEX Region

    Science.gov (United States)

    Bentzien, Sabrina; Bollmeyer, Christoph; Crewell, Susanne; Friederichs, Petra; Hense, Andreas; Keller, Jan; Keune, Jessica; Kneifel, Stefan; Ohlwein, Christian; Pscheidt, Ieda; Redl, Stephanie; Steinke, Sandra

    2014-05-01

    A High-resolution Reanalysis for the European CORDEX Region Within the Hans-Ertel-Centre for Weather Research (HErZ), the climate monitoring branch concentrates efforts on the assessment and analysis of regional climate in Germany and Europe. In joint cooperation with DWD (German Meteorological Service), a high-resolution reanalysis system based on the COSMO model has been developed. Reanalyses gain more and more importance as a source of meteorological information for many purposes and applications. Several global reanalyses projects (e.g., ERA, MERRA, CSFR, JMA9) produce and verify these data sets to provide time series as long as possible combined with a high data quality. Due to a spatial resolution down to 50-70km and 3-hourly temporal output, they are not suitable for small scale problems (e.g., regional climate assessment, meso-scale NWP verification, input for subsequent models such as river runoff simulations). The implementation of regional reanalyses based on a limited area model along with a data assimilation scheme is able to generate reanalysis data sets with high spatio-temporal resolution. The work presented here focuses on the regional reanalysis for Europe with a domain matching the CORDEX-EURO-11 specifications, albeit at a higher spatial resolution, i.e., 0.055° (6km) instead of 0.11° (12km). The COSMO reanalysis system comprises the assimilation of observational data using the existing nudging scheme of COSMO and is complemented by a special soil moisture analysis and boundary conditions given by ERA-interim data. The reanalysis data set currently covers 6 years (2007-2012). The evaluation of the reanalyses is done using independent observations with special emphasis on precipitation and high-impact weather situations. The development and evaluation of the COSMO-based reanalysis for the CORDEX-Euro domain can be seen as a preparation for joint European activities on the development of an ensemble system of regional reanalyses for Europe.

  13. High Time Resolution Astrophysics

    CERN Document Server

    Phelan, Don; Shearer, Andrew

    2008-01-01

    High Time Resolution Astrophysics (HTRA) is an important new window to the universe and a vital tool in understanding a range of phenomena from diverse objects and radiative processes. This importance is demonstrated in this volume with the description of a number of topics in astrophysics, including quantum optics, cataclysmic variables, pulsars, X-ray binaries and stellar pulsations to name a few. Underlining this science foundation, technological developments in both instrumentation and detectors are described. These instruments and detectors combined cover a wide range of timescales and can measure fluxes, spectra and polarisation. These advances make it possible for HTRA to make a big contribution to our understanding of the Universe in the next decade.

  14. High resolution ultrasonic densitometer

    International Nuclear Information System (INIS)

    Dress, W.B.

    1983-01-01

    The velocity of torsional stress pulses in an ultrasonic waveguide of non-circular cross section is affected by the temperature and density of the surrounding medium. Measurement of the transit times of acoustic echoes from the ends of a sensor section are interpreted as level, density, and temperature of the fluid environment surrounding that section. This paper examines methods of making these measurements to obtain high resolution, temperature-corrected absolute and relative density and level determinations of the fluid. Possible applications include on-line process monitoring, a hand-held density probe for battery charge state indication, and precise inventory control for such diverse fluids as uranium salt solutions in accountability storage and gasoline in service station storage tanks

  15. Simulation study for high resolution alpha particle spectrometry with mesh type collimator

    International Nuclear Information System (INIS)

    Park, Seunghoon; Kwak, Sungwoo; Kang, Hanbyeol; Shin, Jungki; Park, Iljin

    2014-01-01

    An alpha particle spectrometry with a mesh type collimator plays a crucial role in identifying specific radionuclide in a radioactive source collected from the atmosphere or environment. The energy resolution is degraded without collimation because particles with a high angle have a longer path to travel in the air. Therefore, collision with the background increases. The collimator can cut out particles which traveling at a high angle. As a result, an energy distribution with high resolution can be obtained. Therefore, the mesh type collimator is simulated for high resolution alpha particle spectrometry. In conclusion, the collimator can improve resolution. With collimator, the collimator is a role of cutting out particles with a high angle, so, low energy tail and broadened energy distribution can be reduced. The mesh diameter is found out as an important factor to control resolution and counting efficiency. Therefore, a target particle, for example, 235 U, can be distinguished by a detector with a collimator under a mixture of various nuclides, for example: 232 U, 238 U, and 232 Th

  16. Low-resolution ship detection from high-altitude aerial images

    Science.gov (United States)

    Qi, Shengxiang; Wu, Jianmin; Zhou, Qing; Kang, Minyang

    2018-02-01

    Ship detection from optical images taken by high-altitude aircrafts such as unmanned long-endurance airships and unmanned aerial vehicles has broad applications in marine fishery management, ship monitoring and vessel salvage. However, the major challenge is the limited capability of information processing on unmanned high-altitude platforms. Furthermore, in order to guarantee the wide detection range, unmanned aircrafts generally cruise at high altitudes, resulting in imagery with low-resolution targets and strong clutters suffered by heavy clouds. In this paper, we propose a low-resolution ship detection method to extract ships from these high-altitude optical images. Inspired by a recent research on visual saliency detection indicating that small salient signals could be well detected by a gradient enhancement operation combined with Gaussian smoothing, we propose the facet kernel filtering to rapidly suppress cluttered backgrounds and delineate candidate target regions from the sea surface. Then, the principal component analysis (PCA) is used to compute the orientation of the target axis, followed by a simplified histogram of oriented gradient (HOG) descriptor to characterize the ship shape property. Finally, support vector machine (SVM) is applied to discriminate real targets and false alarms. Experimental results show that the proposed method actually has high efficiency in low-resolution ship detection.

  17. Gas scintillation glass GEM detector for high-resolution X-ray imaging and CT

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, T., E-mail: fujiwara-t@aist.go.jp [Research Institute for Measurement and Analytical Instrumentation, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8568 (Japan); Mitsuya, Y. [Nuclear Professional School, The University of Tokyo, Tokai, Naka, Ibaraki 319-1188 (Japan); Fushie, T. [Radiment Lab. Inc., Setagaya, Tokyo 156-0044 (Japan); Murata, K.; Kawamura, A.; Koishikawa, A. [XIT Co., Naruse, Machida, Tokyo 194-0045 (Japan); Toyokawa, H. [Research Institute for Measurement and Analytical Instrumentation, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8568 (Japan); Takahashi, H. [Institute of Engineering Innovation, School of Engineering, The University of Tokyo, Bunkyo, Tokyo 113-8654 (Japan)

    2017-04-01

    A high-spatial-resolution X-ray-imaging gaseous detector has been developed with a single high-gas-gain glass gas electron multiplier (G-GEM), scintillation gas, and optical camera. High-resolution X-ray imaging of soft elements is performed with a spatial resolution of 281 µm rms and an effective area of 100×100 mm. In addition, high-resolution X-ray 3D computed tomography (CT) is successfully demonstrated with the gaseous detector. It shows high sensitivity to low-energy X-rays, which results in high-contrast radiographs of objects containing elements with low atomic numbers. In addition, the high yield of scintillation light enables fast X-ray imaging, which is an advantage for constructing CT images with low-energy X-rays.

  18. Novel techniques in VUV high-resolution spectroscopy

    NARCIS (Netherlands)

    Ubachs, W.M.G.; Salumbides, E.J.; Eikema, K.S.E.; de Oliveira, N.; Nahon, L.

    2014-01-01

    Novel VUV sources and techniques for VUV spectroscopy are reviewed. Laser-based VUV sources have been developed via non-linear upconversion of laser pulses in the nanosecond (ns), the picosecond (ps), and femtosecond (fs) domain, and are applied in high-resolution gas phase spectroscopic studies.

  19. Duchenne muscular dystrophy: High-resolution melting curve ...

    African Journals Online (AJOL)

    Duchenne muscular dystrophy: High-resolution melting curve analysis as an affordable diagnostic mutation scanning tool in a South African cohort. ... Genetic screening for D/BMD in South Africa currently includes multiple ligase-dependent probe amplification (MLPA) for exonic deletions and duplications and linkage ...

  20. High-Resolution 3 T MR Microscopy Imaging of Arterial Walls

    International Nuclear Information System (INIS)

    Sailer, Johannes; Rand, Thomas; Berg, Andreas; Sulzbacher, Irene; Peloschek, P.; Hoelzenbein, Thomas; Lammer, Johannes

    2006-01-01

    Purpose. To achieve a high spatial resolution in MR imaging that allows for clear visualization of anatomy and even histology and documentation of plaque morphology in in vitro samples from patients with advanced atherosclerosis. A further objective of our study was to evaluate whether T2-weighted high-resolution MR imaging can provide accurate classification of atherosclerotic plaque according to a modified American Heart Association classification. Methods. T2-weighted images of arteries were obtained in 13 in vitro specimens using a 3 T MR unit (Medspec 300 Avance/Bruker, Ettlingen, Germany) combined with a dedicated MR microscopy system. Measurement parameters were: T2-weighted sequences with TR 3.5 sec, TE 15-120 msec; field of view (FOV) 1.4 x 1.4; NEX 8; matrix 192; and slice thickness 600 μm. MR measurements were compared with corresponding histologic sections. Results. We achieved excellent spatial and contrast resolution in all specimens. We found high agreement between MR images and histology with regard to the morphology and extent of intimal proliferations in all but 2 specimens. We could differentiate fibrous caps and calcifications from lipid plaque components based on differences in signal intensity in order to differentiate hard and soft atheromatous plaques. Hard plaques with predominantly intimal calcifications were found in 7 specimens, and soft plaques with a cholesterol/lipid content in 5 cases. In all specimens, hemorrhage or thrombus formation, and fibrotic and hyalinized tissue could be detected on both MR imaging and histopathology. Conclusion. High-resolution, high-field MR imaging of arterial walls demonstrates the morphologic features, volume, and extent of intimal proliferations with high spatial and contrast resolution in in vitro specimens and can differentiate hard and soft plaques

  1. Motivation for an SSC detector with ultra-high resolution photon detection

    International Nuclear Information System (INIS)

    Gunion, J.F.; Kane, G.

    1992-01-01

    It is well known that incorporating ultra-high resolution photon detection into a general purpose detector for the SSC will be extremely difficult. The authors will argue that the physics signals that could be missed without such resolution are of such importance that a special purpose detector designed specifically for photon final state modes should be constructed, if sufficient resolution cannot be achieved with general purpose detectors. The potentially great value of these signals as a probe of extremely high mass scales is stressed

  2. Comparison of Two Grid Refinement Approaches for High Resolution Regional Climate Modeling: MPAS vs WRF

    Science.gov (United States)

    Leung, L.; Hagos, S. M.; Rauscher, S.; Ringler, T.

    2012-12-01

    This study compares two grid refinement approaches using global variable resolution model and nesting for high-resolution regional climate modeling. The global variable resolution model, Model for Prediction Across Scales (MPAS), and the limited area model, Weather Research and Forecasting (WRF) model, are compared in an idealized aqua-planet context with a focus on the spatial and temporal characteristics of tropical precipitation simulated by the models using the same physics package from the Community Atmosphere Model (CAM4). For MPAS, simulations have been performed with a quasi-uniform resolution global domain at coarse (1 degree) and high (0.25 degree) resolution, and a variable resolution domain with a high-resolution region at 0.25 degree configured inside a coarse resolution global domain at 1 degree resolution. Similarly, WRF has been configured to run on a coarse (1 degree) and high (0.25 degree) resolution tropical channel domain as well as a nested domain with a high-resolution region at 0.25 degree nested two-way inside the coarse resolution (1 degree) tropical channel. The variable resolution or nested simulations are compared against the high-resolution simulations that serve as virtual reality. Both MPAS and WRF simulate 20-day Kelvin waves propagating through the high-resolution domains fairly unaffected by the change in resolution. In addition, both models respond to increased resolution with enhanced precipitation. Grid refinement induces zonal asymmetry in precipitation (heating), accompanied by zonal anomalous Walker like circulations and standing Rossby wave signals. However, there are important differences between the anomalous patterns in MPAS and WRF due to differences in the grid refinement approaches and sensitivity of model physics to grid resolution. This study highlights the need for "scale aware" parameterizations in variable resolution and nested regional models.

  3. Toward high-resolution NMR spectroscopy of microscopic liquid samples

    Energy Technology Data Exchange (ETDEWEB)

    Butler, Mark C.; Mehta, Hardeep S.; Chen, Ying; Reardon, Patrick N.; Renslow, Ryan S.; Khbeis, Michael; Irish, Duane; Mueller, Karl T.

    2017-01-01

    A longstanding limitation of high-resolution NMR spectroscopy is the requirement for samples to have macroscopic dimensions. Commercial probes, for example, are designed for volumes of at least 5 mL, in spite of decades of work directed toward the goal of miniaturization. Progress in miniaturizing inductive detectors has been limited by a perceived need to meet two technical requirements: (1) minimal separation between the sample and the detector, which is essential for sensitivity, and (2) near-perfect magnetic-field homogeneity at the sample, which is typically needed for spectral resolution. The first of these requirements is real, but the second can be relaxed, as we demonstrate here. By using pulse sequences that yield high-resolution spectra in an inhomogeneous field, we eliminate the need for near-perfect field homogeneity and the accompanying requirement for susceptibility matching of microfabricated detector components. With this requirement removed, typical imperfections in microfabricated components can be tolerated, and detector dimensions can be matched to those of the sample, even for samples of volume << 5 uL. Pulse sequences that are robust to field inhomogeneity thus enable small-volume detection with optimal sensitivity. We illustrate the potential of this approach to miniaturization by presenting spectra acquired with a flat-wire detector that can easily be scaled to subnanoliter volumes. In particular, we report high-resolution NMR spectroscopy of an alanine sample of volume 500 pL.

  4. Gamma-Ray Imager With High Spatial And Spectral Resolution

    Science.gov (United States)

    Callas, John L.; Varnell, Larry S.; Wheaton, William A.; Mahoney, William A.

    1996-01-01

    Gamma-ray instrument developed to enable both two-dimensional imaging at relatively high spatial resolution and spectroscopy at fractional-photon-energy resolution of about 10 to the negative 3rd power in photon-energy range from 10 keV to greater than 10 MeV. In its spectroscopic aspect, instrument enables identification of both narrow and weak gamma-ray spectral peaks.

  5. Fuzzy Classification of High Resolution Remote Sensing Scenes Using Visual Attention Features

    Directory of Open Access Journals (Sweden)

    Linyi Li

    2017-01-01

    Full Text Available In recent years the spatial resolutions of remote sensing images have been improved greatly. However, a higher spatial resolution image does not always lead to a better result of automatic scene classification. Visual attention is an important characteristic of the human visual system, which can effectively help to classify remote sensing scenes. In this study, a novel visual attention feature extraction algorithm was proposed, which extracted visual attention features through a multiscale process. And a fuzzy classification method using visual attention features (FC-VAF was developed to perform high resolution remote sensing scene classification. FC-VAF was evaluated by using remote sensing scenes from widely used high resolution remote sensing images, including IKONOS, QuickBird, and ZY-3 images. FC-VAF achieved more accurate classification results than the others according to the quantitative accuracy evaluation indices. We also discussed the role and impacts of different decomposition levels and different wavelets on the classification accuracy. FC-VAF improves the accuracy of high resolution scene classification and therefore advances the research of digital image analysis and the applications of high resolution remote sensing images.

  6. Variational data assimilation system with nesting model for high resolution ocean circulation

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, Yoichi; Igarashi, Hiromichi; Hiyoshi, Yoshimasa; Sasaki, Yuji; Wakamatsu, Tsuyoshi; Awaji, Toshiyuki [Center for Earth Information Science and Technology, Japan Agency for Marine-Earth Science and Technology, 3173-25 Showa-machi, Kanazawa-Ku, Yokohama 236-0001 (Japan); In, Teiji [Japan Marine Science Foundation, 4-24, Minato-cho, Mutsu, Aomori, 035-0064 (Japan); Nakada, Satoshi [Graduate School of Maritime Science, Kobe University, 5-1-1, Fukae-minamimachi, Higashinada-Ku, Kobe, 658-0022 (Japan); Nishina, Kei, E-mail: ishikaway@jamstec.go.jp [Graduate School of Science, Kyoto University, Kitashirakawaoiwake-cho, Sakyo-Ku, Kyoto, 606-8502 (Japan)

    2015-10-15

    To obtain the high-resolution analysis fields for ocean circulation, a new incremental approach is developed using a four-dimensional variational data assimilation system with nesting models. The results show that there are substantial biases when using a classical method combined with data assimilation and downscaling, caused by different dynamics resulting from the different resolutions of the models used within the nesting models. However, a remarkable reduction in biases of the low-resolution model relative to the high-resolution model was observed using our new approach in narrow strait regions, such as the Tsushima and Tsugaru straits, where the difference in the dynamics represented by the high- and low-resolution models is substantial. In addition, error reductions are demonstrated in the downstream region of these narrow channels associated with the propagation of information through the model dynamics. (paper)

  7. Real-time database for high resolution neutron monitor measurements

    Energy Technology Data Exchange (ETDEWEB)

    Steigies, Christian T.; Rother, Oliver M.; Wimmer-Schweingruber, Robert F.; Heber, Bernd [IEAP, Christian-Albrechts-Universitaet zu Kiel (Germany)

    2008-07-01

    The worldwide network of standardised neutron monitors is, after 50 years, still the state-of-the-art instrumentation to measure spectral variations of the primary cosmic ray component. These measurements are an ideal complement to space based cosmic ray measurements. Data from the approximately 50 IGY and NM64 neutron monitors is stored locally but also available through data collections sites like the World Data Center (WDC) or the IZMIRAN ftp server. The data from the WDC is in a standard format, but only hourly values are available. IZMIRAN collects the data in the best available time resolution, but the data arrives on the ftp server only hours, sometimes days, after the measurements. Also, the high time-resolution measurements of the different stations do not have a common format, a conversion routine for each station is needed before they can be used for scientific analysis. Supported by the 7th framework program of the European Commission, we are setting up a real-time database where high resolution cosmic ray measurements will be stored and accessible immediately after the measurement. Stations that do not have 1-minute resolution measurements will be upgraded to 1-minute or better resolution with an affordable standard registration system, that will submit the measurements to the database via the internet in real-time.

  8. High resolution imaging of boron carbide microstructures

    International Nuclear Information System (INIS)

    MacKinnon, I.D.R.; Aselage, T.; Van Deusen, S.B.

    1986-01-01

    Two samples of boron carbide have been examined using high resolution transmission electron microscopy (HRTEM). A hot-pressed B 13 C 2 sample shows a high density of variable width twins normal to (10*1). Subtle shifts or offsets of lattice fringes along the twin plane and normal to approx.(10*5) were also observed. A B 4 C powder showed little evidence of stacking disorder in crystalline regions

  9. A subspace approach to high-resolution spectroscopic imaging.

    Science.gov (United States)

    Lam, Fan; Liang, Zhi-Pei

    2014-04-01

    To accelerate spectroscopic imaging using sparse sampling of (k,t)-space and subspace (or low-rank) modeling to enable high-resolution metabolic imaging with good signal-to-noise ratio. The proposed method, called SPectroscopic Imaging by exploiting spatiospectral CorrElation, exploits a unique property known as partial separability of spectroscopic signals. This property indicates that high-dimensional spectroscopic signals reside in a very low-dimensional subspace and enables special data acquisition and image reconstruction strategies to be used to obtain high-resolution spatiospectral distributions with good signal-to-noise ratio. More specifically, a hybrid chemical shift imaging/echo-planar spectroscopic imaging pulse sequence is proposed for sparse sampling of (k,t)-space, and a low-rank model-based algorithm is proposed for subspace estimation and image reconstruction from sparse data with the capability to incorporate prior information and field inhomogeneity correction. The performance of the proposed method has been evaluated using both computer simulations and phantom studies, which produced very encouraging results. For two-dimensional spectroscopic imaging experiments on a metabolite phantom, a factor of 10 acceleration was achieved with a minimal loss in signal-to-noise ratio compared to the long chemical shift imaging experiments and with a significant gain in signal-to-noise ratio compared to the accelerated echo-planar spectroscopic imaging experiments. The proposed method, SPectroscopic Imaging by exploiting spatiospectral CorrElation, is able to significantly accelerate spectroscopic imaging experiments, making high-resolution metabolic imaging possible. Copyright © 2014 Wiley Periodicals, Inc.

  10. Hepatic Vein Arrival Time for Diagnosis of Liver Cirrhosis: A 10-Year Single-Center Experience With Contrast-Enhanced Sonography.

    Science.gov (United States)

    Abbattista, Teresa; Ridolfi, Francesco; Consalvo, Giovanni Traina; Brunelli, Eugenio

    2016-10-01

    To evaluate the performance of contrast-enhanced sonography with a second-generation contrast agent in assessing the severity of chronic diffuse liver disease and differentiating cirrhotic from noncirrhotic liver disease. Contrast-enhanced sonography was performed after intravenous bolus injection of a second-generation contrast agent in 14 healthy control participants and 160 consecutive patients with cirrhotic and noncirrhotic liver disease (n = 78 and 82, respectively) enrolled between March 2004 and April 2014. The intensity of enhancement in a main hepatic vein was used to determine hepatic vein arrival time, time to peak intensity, and peak contrast enhancement. The hepatic vein arrival time was lower in cirrhotic patients compared with both noncirrhotic patients and controls (mean ± SD, 15.0 ± 2.8, 21.5 ± 3.4, and 25.6 ± 4.7 seconds, respectively; P < .05). The hepatic vein arrival time in noncirrhotic patients was also significantly lower than that in controls (P < .05). The time to peak intensity was significantly lower in cirrhotic patients compared with noncirrhotic patients and controls (40.7 ± 13.7, 49.4 ± 12.8, and 51.2 ± 13.7 seconds; P < .05). A receiver operating characteristic curve analysis revealed that the hepatic vein arrival time more accurately excluded a diagnosis of liver cirrhosis than the time to peak intensity (area under the receiver operating characteristic curve, 0.953 versus 0.694). Specifically, a hepatic vein arrival time cutoff value of 17 seconds excluded liver cirrhosis with 91.1% sensitivity and 93.6% specificity. Contrast-enhanced sonography is a valid alternative method for noninvasive staging of liver diseases. The hepatic vein arrival time could be used to exclude liver cirrhosis in a clinical setting.

  11. High-resolution spectroscopic probes of collisions and half-collisions

    Energy Technology Data Exchange (ETDEWEB)

    Hall, G.E. [Brookhaven National Laboratory, Upton, NY (United States)

    1993-12-01

    Research in this program explores the dynamics of gas phase collisions and photodissociation by high-resolution laser spectroscopy. Simultaneous state and velocity detection frequently permits a determination of scalar or vector correlations among products. The correlated product distributions are always more informative, and often easier to interpret than the uncorrelated product state distributions. The authors have recently built an apparatus to record transient absorption spectra with 50 nS time resolution and 20 MHz frequency resolution using a single frequency Ti:sapphire laser. The photodissociation of NCCN and C{sub 2}H{sub 5}SCN at 193 nm is discussed.

  12. Sonography of cat scratch disease.

    Science.gov (United States)

    Melville, David M; Jacobson, Jon A; Downie, Brian; Biermann, J Sybil; Kim, Sung Moon; Yablon, Corrie M

    2015-03-01

    To characterize the sonographic features of cat scratch disease and to identify features that allow differentiation from other causes of medial epitrochlear masses. After Institutional Review Board approval was obtained, patients who underwent sonography for a medial epitrochlear mass or lymph node were identified via the radiology information system. Patients were divided into 2 groups: cat scratch disease and non-cat scratch disease, based on pathologic results and clinical information. Sonograms were retrospectively reviewed and characterized with respect to dimension, shape (round, oval, or lobular), symmetry, location (subcutaneous or intramuscular), multiplicity, echogenicity (anechoic, hypoechoic, isoechoic, hyperechoic, or mixed), hyperechoic hilum (present or absent), adjacent anechoic or hypoechoic area, hyperemia (present or absent), pattern of hyperemia if present (central, peripheral, or mixed), increased posterior through-transmission (present or absent), and shadowing (present or absent). Sonographic findings were compared between the patients with and without cat scratch disease. The final patient group consisted of 5 cases of cat scratch disease and 16 cases of other causes of medial epitrochlear masses. The 2 sonographic findings that were significantly different between the cat scratch disease and non-cat scratch disease cases included mass asymmetry (P = .0062) and the presence of a hyperechoic hilum (P = .0075). The other sonographic findings showed no significant differences between the groups. The sonographic finding of an epitrochlear mass due to cat scratch disease most commonly is that of a hypoechoic lobular or oval mass with central hyperemia and a possible adjacent fluid collection; however, the presence of asymmetry and a hyperechoic hilum differentiate cat scratch disease from other etiologies. © 2015 by the American Institute of Ultrasound in Medicine.

  13. The demonstration of the auditory ossicles by high resolution CT

    International Nuclear Information System (INIS)

    Lloyd, G.A.S.; Boulay, G.H. du; Phelps, P.D.; Pullicino, P.

    1979-01-01

    The high resolution CT scanning system introduced by EMI in 1978 has added a new dimension to computerised tomography in otology. The apparatus used for this study was an EMI CT 5005 body scanner adapted for head and neck scanning and incorporating a high resolution facility. The latter has proved most advantageous in areas of relatively high differential absorption, so that its application to the demonstration of abnormalities in the petrous temporal bone, and in particular middle ear disease, has been very rewarding. Traumatic ossicular disruptions may now be demonstrated and the high contrast of CT often shows them better than conventional hypocycloidal tomography. The stapes is also better visualised and congenital abnormalities of its superstructure have been recorded. These studies have been achieved with a very acceptable level of radiation to the eye, lens and cornea and the technique is clearly a rival to conventional pluridirectional tomography in the assessment of the petrous temporal bone. With further design improvements high resolution CT could completely replace existing techniques. (orig.) [de

  14. High resolution NMR theory and chemical applications

    CERN Document Server

    Becker, Edwin D

    2012-01-01

    High Resolution NMR: Theory and Chemical Applications discusses the principles and theory of nuclear magnetic resonance and how this concept is used in the chemical sciences. This book is written at an intermediate level, with mathematics used to augment verbal descriptions of the phenomena. This text pays attention to developing and interrelating four approaches - the steady state energy levels, the rotating vector picture, the density matrix, and the product operator formalism. The style of this book is based on the assumption that the reader has an acquaintance with the general principles of quantum mechanics, but no extensive background in quantum theory or proficiency in mathematics is required. This book begins with a description of the basic physics, together with a brief account of the historical development of the field. It looks at the study of NMR in liquids, including high resolution NMR in the solid state and the principles of NMR imaging and localized spectroscopy. This book is intended to assis...

  15. Principles of high resolution NMR in solids

    CERN Document Server

    Mehring, Michael

    1983-01-01

    The field of Nuclear Magnetic Resonance (NMR) has developed at a fascinating pace during the last decade. It always has been an extremely valuable tool to the organic chemist by supplying molecular "finger print" spectra at the atomic level. Unfortunately the high resolution achievable in liquid solutions could not be obtained in solids and physicists and physical chemists had to live with unresolved lines open to a wealth of curve fitting procedures and a vast amount of speculations. High resolution NMR in solids seemed to be a paradoxon. Broad structure­ less lines are usually encountered when dealing with NMR in solids. Only with the recent advent of mUltiple pulse, magic angle, cross-polarization, two-dimen­ sional and multiple-quantum spectroscopy and other techniques during the last decade it became possible to resolve finer details of nuclear spin interactions in solids. I have felt that graduate students, researchers and others beginning to get involved with these techniques needed a book which trea...

  16. High resolution NMR theory and chemical applications

    CERN Document Server

    Becker, Edwin D

    1999-01-01

    High Resolution NMR provides a broad treatment of the principles and theory of nuclear magnetic resonance (NMR) as it is used in the chemical sciences. It is written at an "intermediate" level, with mathematics used to augment, rather than replace, clear verbal descriptions of the phenomena. The book is intended to allow a graduate student, advanced undergraduate, or researcher to understand NMR at a fundamental level, and to see illustrations of the applications of NMR to the determination of the structure of small organic molecules and macromolecules, including proteins. Emphasis is on the study of NMR in liquids, but the treatment also includes high resolution NMR in the solid state and the principles of NMR imaging and localized spectroscopy. Careful attention is given to developing and interrelating four approaches - steady state energy levels, the rotating vector picture, the density matrix, and the product operator formalism. The presentation is based on the assumption that the reader has an acquaintan...

  17. High resolution study of high mass pairs and high transverse momentum particles

    International Nuclear Information System (INIS)

    Smith, S.R.

    1983-01-01

    Preliminary experiments involving the high resolution spectrometer (experiment 605) at Fermilab are described. The spectrometer is designed for the study of pairs of particles at large invariant masses and single particles at large transverse momenta. A number of applications of the apparatus in the study of Drell-Yan processes, e.g. transverse momentum measurement, are discussed

  18. Localization-based super-resolution imaging meets high-content screening.

    Science.gov (United States)

    Beghin, Anne; Kechkar, Adel; Butler, Corey; Levet, Florian; Cabillic, Marine; Rossier, Olivier; Giannone, Gregory; Galland, Rémi; Choquet, Daniel; Sibarita, Jean-Baptiste

    2017-12-01

    Single-molecule localization microscopy techniques have proven to be essential tools for quantitatively monitoring biological processes at unprecedented spatial resolution. However, these techniques are very low throughput and are not yet compatible with fully automated, multiparametric cellular assays. This shortcoming is primarily due to the huge amount of data generated during imaging and the lack of software for automation and dedicated data mining. We describe an automated quantitative single-molecule-based super-resolution methodology that operates in standard multiwell plates and uses analysis based on high-content screening and data-mining software. The workflow is compatible with fixed- and live-cell imaging and allows extraction of quantitative data like fluorophore photophysics, protein clustering or dynamic behavior of biomolecules. We demonstrate that the method is compatible with high-content screening using 3D dSTORM and DNA-PAINT based super-resolution microscopy as well as single-particle tracking.

  19. High-resolution RCMs as pioneers for future GCMs

    Science.gov (United States)

    Schar, C.; Ban, N.; Arteaga, A.; Charpilloz, C.; Di Girolamo, S.; Fuhrer, O.; Hoefler, T.; Leutwyler, D.; Lüthi, D.; Piaget, N.; Ruedisuehli, S.; Schlemmer, L.; Schulthess, T. C.; Wernli, H.

    2017-12-01

    Currently large efforts are underway to refine the horizontal resolution of global and regional climate models to O(1 km), with the intent to represent convective clouds explicitly rather than using semi-empirical parameterizations. This refinement will move the governing equations closer to first principles and is expected to reduce the uncertainties of climate models. High resolution is particularly attractive in order to better represent critical cloud feedback processes (e.g. related to global climate sensitivity and extratropical summer convection) and extreme events (such as heavy precipitation events, floods, and hurricanes). The presentation will be illustrated using decade-long simulations at 2 km horizontal grid spacing, some of these covering the European continent on a computational mesh with 1536x1536x60 grid points. To accomplish such simulations, use is made of emerging heterogeneous supercomputing architectures, using a version of the COSMO limited-area weather and climate model that is able to run entirely on GPUs. Results show that kilometer-scale resolution dramatically improves the simulation of precipitation in terms of the diurnal cycle and short-term extremes. The modeling framework is used to address changes of precipitation scaling with climate change. It is argued that already today, modern supercomputers would in principle enable global atmospheric convection-resolving climate simulations, provided appropriately refactored codes were available, and provided solutions were found to cope with the rapidly growing output volume. A discussion will be provided of key challenges affecting the design of future high-resolution climate models. It is suggested that km-scale RCMs should be exploited to pioneer this terrain, at a time when GCMs are not yet available at such resolutions. Areas of interest include the development of new parameterization schemes adequate for km-scale resolution, the exploration of new validation methodologies and data

  20. Methylation-Sensitive High Resolution Melting (MS-HRM).

    Science.gov (United States)

    Hussmann, Dianna; Hansen, Lise Lotte

    2018-01-01

    Methylation-Sensitive High Resolution Melting (MS-HRM) is an in-tube, PCR-based method to detect methylation levels at specific loci of interest. A unique primer design facilitates a high sensitivity of the assays enabling detection of down to 0.1-1% methylated alleles in an unmethylated background.Primers for MS-HRM assays are designed to be complementary to the methylated allele, and a specific annealing temperature enables these primers to anneal both to the methylated and the unmethylated alleles thereby increasing the sensitivity of the assays. Bisulfite treatment of the DNA prior to performing MS-HRM ensures a different base composition between methylated and unmethylated DNA, which is used to separate the resulting amplicons by high resolution melting.The high sensitivity of MS-HRM has proven useful for detecting cancer biomarkers in a noninvasive manner in urine from bladder cancer patients, in stool from colorectal cancer patients, and in buccal mucosa from breast cancer patients. MS-HRM is a fast method to diagnose imprinted diseases and to clinically validate results from whole-epigenome studies. The ability to detect few copies of methylated DNA makes MS-HRM a key player in the quest for establishing links between environmental exposure, epigenetic changes, and disease.

  1. High-resolution MR imaging of talar osteochondral lesions with new classification

    Energy Technology Data Exchange (ETDEWEB)

    Griffith, James Francis; Lau, Domily Ting Yi; Yeung, David Ka Wai [Prince of Wales Hospital, Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Shatin, NT (China); Wong, Margaret Wan Nar [Prince of Wales Hospital, Chinese University of Hong Kong, Department of Orthopaedics and Traumatology, Shatin (China)

    2012-04-15

    Retrospective review of high-resolution MR imaging features of talar dome osteochondral lesions and development of new classification system based on these features. Over the past 7 years, 70 osteochondral lesions of the talar dome from 70 patients (49 males, 21 females, mean age 42 years, range 15-62 years) underwent high-resolution MR imaging with a microscopy coil at 1.5 T. Sixty-one (87%) of 70 lesions were located on the medial central aspect and ten (13%) lesions were located on the lateral central aspect of the talar dome. Features evaluated included cartilage fracture, osteochondral junction separation, subchondral bone collapse, bone:bone separation, and marrow change. Based on these findings, a new five-part grading system was developed. Signal-to-noise characteristics of microscopy coil imaging at 1.5 T were compared to dedicated ankle coil imaging at 3 T. Microscopy coil imaging at 1.5 T yielded 20% better signal-to-noise characteristics than ankle coil imaging at 3 T. High-resolution MR revealed that osteochondral junction separation, due to focal collapse of the subchondral bone, was a common feature, being present in 28 (45%) of 61 medial central osteochondral lesions. Reparative cartilage hypertrophy and bone:bone separation in the absence of cartilage fracture were also common findings. Complete osteochondral separation was uncommon. A new five-part grading system incorporating features revealed by high-resolution MR imaging was developed. High-resolution MRI reveals clinically pertinent features of talar osteochondral lesions, which should help comprehension of symptomatology and enhance clinical decision-making. These features were incorporated in a new MR-based grading system. Whenever possible, symptomatic talar osteochondral lesions should be assessed by high-resolution MR imaging. (orig.)

  2. High-resolution MR imaging of talar osteochondral lesions with new classification

    International Nuclear Information System (INIS)

    Griffith, James Francis; Lau, Domily Ting Yi; Yeung, David Ka Wai; Wong, Margaret Wan Nar

    2012-01-01

    Retrospective review of high-resolution MR imaging features of talar dome osteochondral lesions and development of new classification system based on these features. Over the past 7 years, 70 osteochondral lesions of the talar dome from 70 patients (49 males, 21 females, mean age 42 years, range 15-62 years) underwent high-resolution MR imaging with a microscopy coil at 1.5 T. Sixty-one (87%) of 70 lesions were located on the medial central aspect and ten (13%) lesions were located on the lateral central aspect of the talar dome. Features evaluated included cartilage fracture, osteochondral junction separation, subchondral bone collapse, bone:bone separation, and marrow change. Based on these findings, a new five-part grading system was developed. Signal-to-noise characteristics of microscopy coil imaging at 1.5 T were compared to dedicated ankle coil imaging at 3 T. Microscopy coil imaging at 1.5 T yielded 20% better signal-to-noise characteristics than ankle coil imaging at 3 T. High-resolution MR revealed that osteochondral junction separation, due to focal collapse of the subchondral bone, was a common feature, being present in 28 (45%) of 61 medial central osteochondral lesions. Reparative cartilage hypertrophy and bone:bone separation in the absence of cartilage fracture were also common findings. Complete osteochondral separation was uncommon. A new five-part grading system incorporating features revealed by high-resolution MR imaging was developed. High-resolution MRI reveals clinically pertinent features of talar osteochondral lesions, which should help comprehension of symptomatology and enhance clinical decision-making. These features were incorporated in a new MR-based grading system. Whenever possible, symptomatic talar osteochondral lesions should be assessed by high-resolution MR imaging. (orig.)

  3. High resolution positron tomography

    International Nuclear Information System (INIS)

    Brownell, G.L.; Burnham, C.A.

    1982-01-01

    The limits of spatial resolution in practical positron tomography are examined. The four factors that limit spatial resolution are: positron range; small angle deviation; detector dimensions and properties; statistics. Of these factors, positron range may be considered the fundamental physical limitation since it is independent of instrument properties. The other factors are to a greater or lesser extent dependent on the design of the tomograph

  4. High-intensity xenon plasma discharge lamp for bulk-sensitive high-resolution photoemission spectroscopy.

    Science.gov (United States)

    Souma, S; Sato, T; Takahashi, T; Baltzer, P

    2007-12-01

    We have developed a highly brilliant xenon (Xe) discharge lamp operated by microwave-induced electron cyclotron resonance (ECR) for ultrahigh-resolution bulk-sensitive photoemission spectroscopy (PES). We observed at least eight strong radiation lines from neutral or singly ionized Xe atoms in the energy region of 8.4-10.7 eV. The photon flux of the strongest Xe I resonance line at 8.437 eV is comparable to that of the He Ialpha line (21.218 eV) from the He-ECR discharge lamp. Stable operation for more than 300 h is achieved by efficient air-cooling of a ceramic tube in the resonance cavity. The high bulk sensitivity and high-energy resolution of PES using the Xe lines are demonstrated for some typical materials.

  5. High resolution, position sensitive detector for energetic particle beams

    International Nuclear Information System (INIS)

    Marsh, E.P.; Strathman, M.D.; Reed, D.A.; Odom, R.W.; Morse, D.H.; Pontau, A.E.

    1993-01-01

    The performance and design of an imaging position sensitive, particle beam detector will be presented. The detector is minimally invasive, operates a wide dynamic range (>10 10 ), and exhibits high spatial resolution. The secondary electrons produced when a particle beam passes through a thin foil are imaged using stigmatic ion optics onto a two-dimensional imaging detector. Due to the low scattering cross section of the 6 nm carbon foil the detector is a minimal perturbation on the primary beam. A prototype detector with an image resolution of approximately 5 μm for a field of view of 1 mm has been reported. A higher resolution detector for imaging small beams (<50 μm) with an image resolution of better than 0.5 μm has since been developed and its design is presented. (orig.)

  6. Interventions for tubal ectopic pregnancy

    NARCIS (Netherlands)

    Hajenius, P. J.; Mol, B. W.; Bossuyt, P. M.; Ankum, W. M.; van der Veen, F.

    2000-01-01

    BACKGROUND: The diagnosis of ectopic pregnancy can now often be made by non-invasive methods due to sensitive pregnancy tests (in urine and serum) and high resolution transvaginal sonography, which have been integrated in diagnostic algorithms. These algorithms, in combination with the increased

  7. High-resolution mapping of forest carbon stocks in the Colombian Amazon

    Directory of Open Access Journals (Sweden)

    G. P. Asner

    2012-07-01

    Full Text Available High-resolution mapping of tropical forest carbon stocks can assist forest management and improve implementation of large-scale carbon retention and enhancement programs. Previous high-resolution approaches have relied on field plot and/or light detection and ranging (LiDAR samples of aboveground carbon density, which are typically upscaled to larger geographic areas using stratification maps. Such efforts often rely on detailed vegetation maps to stratify the region for sampling, but existing tropical forest maps are often too coarse and field plots too sparse for high-resolution carbon assessments. We developed a top-down approach for high-resolution carbon mapping in a 16.5 million ha region (> 40% of the Colombian Amazon – a remote landscape seldom documented. We report on three advances for large-scale carbon mapping: (i employing a universal approach to airborne LiDAR-calibration with limited field data; (ii quantifying environmental controls over carbon densities; and (iii developing stratification- and regression-based approaches for scaling up to regions outside of LiDAR coverage. We found that carbon stocks are predicted by a combination of satellite-derived elevation, fractional canopy cover and terrain ruggedness, allowing upscaling of the LiDAR samples to the full 16.5 million ha region. LiDAR-derived carbon maps have 14% uncertainty at 1 ha resolution, and the regional map based on stratification has 28% uncertainty in any given hectare. High-resolution approaches with quantifiable pixel-scale uncertainties will provide the most confidence for monitoring changes in tropical forest carbon stocks. Improved confidence will allow resource managers and decision makers to more rapidly and effectively implement actions that better conserve and utilize forests in tropical regions.

  8. The implementation of sea ice model on a regional high-resolution scale

    Science.gov (United States)

    Prasad, Siva; Zakharov, Igor; Bobby, Pradeep; McGuire, Peter

    2015-09-01

    The availability of high-resolution atmospheric/ocean forecast models, satellite data and access to high-performance computing clusters have provided capability to build high-resolution models for regional ice condition simulation. The paper describes the implementation of the Los Alamos sea ice model (CICE) on a regional scale at high resolution. The advantage of the model is its ability to include oceanographic parameters (e.g., currents) to provide accurate results. The sea ice simulation was performed over Baffin Bay and the Labrador Sea to retrieve important parameters such as ice concentration, thickness, ridging, and drift. Two different forcing models, one with low resolution and another with a high resolution, were used for the estimation of sensitivity of model results. Sea ice behavior over 7 years was simulated to analyze ice formation, melting, and conditions in the region. Validation was based on comparing model results with remote sensing data. The simulated ice concentration correlated well with Advanced Microwave Scanning Radiometer for EOS (AMSR-E) and Ocean and Sea Ice Satellite Application Facility (OSI-SAF) data. Visual comparison of ice thickness trends estimated from the Soil Moisture and Ocean Salinity satellite (SMOS) agreed with the simulation for year 2010-2011.

  9. Performance of a high resolution cavity beam position monitor system

    Science.gov (United States)

    Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Pete; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Honda, Yosuke; Kolomensky, Yury; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; Thomson, Mark; Urakawa, Junji; Vogel, Vladimir; Ward, David; White, Glen

    2007-07-01

    It has been estimated that an RF cavity Beam Position Monitor (BPM) could provide a position measurement resolution of less than 1 nm. We have developed a high resolution cavity BPM and associated electronics. A triplet comprised of these BPMs was installed in the extraction line of the Accelerator Test Facility (ATF) at the High Energy Accelerator Research Organization (KEK) for testing with its ultra-low emittance beam. The three BPMs were each rigidly mounted inside an alignment frame on six variable-length struts which could be used to move the BPMs in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, we have demonstrated a position resolution of 15.6 nm and a tilt resolution of 2.1 μrad over a dynamic range of approximately ±20 μm.

  10. The high resolution shear wave seismic reflection technique

    International Nuclear Information System (INIS)

    Johnson, W.J.; Clark, J.C.

    1991-04-01

    This report presents the state-of-the-art of the high resolution S-wave reflection technique. Published and unpublished literature has been reviewed and discussions have been held with experts. Result is to confirm that the proposed theoretical and practical basis for identifying aquifer systems using both P- and S-wave reflections is sound. Knowledge of S-wave velocity and P-wave velocity is a powerful tool for assessing the fluid characteristics of subsurface layers. Material properties and lateral changes in material properties such as change from clay to sand, can be inferred from careful dual evaluation of P and S-wave records. The high resolution S-wave reflection technique has seen its greatest application to date as part of geotechnical studies for building foundations in the Far East. Information from this type of study has been evaluated and will be incorporated in field studies. In particular, useful information regarding S-wave sources, noise suppression and recording procedures will be incorporated within the field studies. Case histories indicate that the best type of site for demonstrating the power of the high resolution S-wave technique will be in unconsolidated soil without excessive structural complexities. More complex sites can form the basis for subsequent research after the basic principles of the technique can be established under relatively uncomplicated conditions

  11. Charge-coupled devices for particle detection with high spatial resolution

    International Nuclear Information System (INIS)

    Farley, F.J.; Damerell, C.J.S.; Gillman, A.R.; Wickens, F.J.

    1980-10-01

    The results of a study of the possible application of a thin microelectronic device (the charge-coupled device) to high energy physics as particle detectors with good spatial resolution which can distinguish between tracks emerging from the primary vertex and those from secondary vertices due to the decay of short lived particles with higher flavours, are reported. Performance characteristics indicating the spatial resolution, particle discrimination, time resolution, readout time and lifetime of such detectors have been obtained. (U.K.)

  12. Rapid calibrated high-resolution hyperspectral imaging using tunable laser source

    Science.gov (United States)

    Nguyen, Lam K.; Margalith, Eli

    2009-05-01

    We present a novel hyperspectral imaging technique based on tunable laser technology. By replacing the broadband source and tunable filters of a typical NIR imaging instrument, several advantages are realized, including: high spectral resolution, highly variable field-of-views, fast scan-rates, high signal-to-noise ratio, and the ability to use optical fiber for efficient and flexible sample illumination. With this technique, high-resolution, calibrated hyperspectral images over the NIR range can be acquired in seconds. The performance of system features will be demonstrated on two example applications: detecting melamine contamination in wheat gluten and separating bovine protein from wheat protein in cattle feed.

  13. High Resolution Higher Energy X-ray Microscope for Mesoscopic Materials

    International Nuclear Information System (INIS)

    Snigireva, I; Snigirev, A

    2013-01-01

    We developed a novel X-ray microscopy technique to study mesoscopically structured materials, employing compound refractive lenses. The easily seen advantage of lens-based methodology is the possibility to retrieve high resolution diffraction pattern and real-space images in the same experimental setup. Methodologically the proposed approach is similar to the studies of crystals by high resolution transmission electron microscopy. The proposed microscope was applied for studying of mesoscopic materials such as natural and synthetic opals, inverted photonic crystals

  14. Solutions on high-resolution multiple configuration system sensors

    Science.gov (United States)

    Liu, Hua; Ding, Quanxin; Guo, Chunjie; Zhou, Liwei

    2014-11-01

    For aim to achieve an improved resolution in modern image domain, a method of continuous zoom multiple configuration, with a core optics is attempt to establish model by novel principle on energy transfer and high accuracy localization, by which the system resolution can be improved with a level in nano meters. A comparative study on traditional vs modern methods can demonstrate that the dialectical relationship and their balance is important, among Merit function, Optimization algorithms and Model parameterization. The effect of system evaluated criterion that MTF, REA, RMS etc. can support our arguments qualitatively.

  15. Development of high-energy resolution inverse photoemission technique

    International Nuclear Information System (INIS)

    Asakura, D.; Fujii, Y.; Mizokawa, T.

    2005-01-01

    We developed a new inverse photoemission (IPES) machine based on a new idea to improve the energy resolution: off-plane Eagle mounting of the optical system in combination with dispersion matching between incoming electron and outgoing photon. In order to achieve dispersion matching, we have employed a parallel plate electron source and have investigated whether the electron beam is obtained as expected. In this paper, we present the principle and design of the new IPES method and report the current status of the high-energy resolution IPES machine

  16. High-Resolution Reciprocal Space Mapping for Characterizing Deformation Structures

    DEFF Research Database (Denmark)

    Pantleon, Wolfgang; Wejdemann, Christian; Jakobsen, Bo

    2014-01-01

    With high-angular resolution three-dimensional X-ray diffraction (3DXRD), quantitative information is gained about dislocation structures in individual grains in the bulk of a macroscopic specimen by acquiring reciprocal space maps. In high-resolution 3D reciprocal space maps of tensile......-deformed copper, individual, almost dislocation-free subgrains are identified from high-intensity peaks and distinguished by their unique combination of orientation and elastic strain; dislocation walls manifest themselves as a smooth cloud of lower intensity. The elastic strain shows only minor variations within...... dynamics is followed in situ during varying loading conditions by reciprocal space mapping: during uninterrupted tensile deformation, formation of subgrains is observed concurrently with broadening of Bragg reflections shortly after the onset of plastic deformation. When the traction is terminated, stress...

  17. Self-triggered image intensifier tube for high-resolution UHECR imaging detector

    CERN Document Server

    Sasaki, M; Jobashi, M

    2003-01-01

    The authors have developed a self-triggered image intensifier tube with high-resolution imaging capability. An image detected by a first image intensifier tube as an electrostatic lens with a photocathode diameter of 100 mm is separated by a half-mirror into a path for CCD readout (768x494 pixels) and a fast control to recognize and trigger the image. The proposed system provides both a high signal-to-noise ratio to improve single photoelectron detection and excellent spatial resolution between 207 and 240 mu m rendering this device a potentially essential tool for high-energy physics and astrophysics experiments, as well as high-speed photography. When combined with a 1-arcmin resolution optical system with 50 deg. field-of-view proposed by the present authors, the observation of ultra high-energy cosmic rays and high-energy neutrinos using this device is expected, leading to revolutionary progress in particle astrophysics as a complementary technique to traditional astronomical observations at multiple wave...

  18. High spectral resolution X-ray observations of AGN

    NARCIS (Netherlands)

    Kaastra, J.S.

    2008-01-01

    brief overview of some highlights of high spectral resolution X-ray observations of AGN is given, mainly obtained with the RGS of XMM-Newton. Future prospects for such observations with XMM-Newton are given.

  19. A high resolution 16 k multi-channel analyzer PC add-on card

    International Nuclear Information System (INIS)

    Kulkarni, C.P.; Paulson, Molly; Vaidya, P.P.

    2001-01-01

    This paper describes the system details of a 16 K channel resolution Multi-Channel Analyzer (MCA) developed at Electronics Division, BARC, which is used in high resolution nuclear spectroscopy systems for pulse height analysis. The high resolution data acquisition PC add-on card is architectured using a state of the art digital circuit design technology which makes use of a Field Programmable Gate Array (FPGA), and some of the most modern and advanced analog counterparts like low power, high speed and high precision comparators, Op-amps, ADCs and DACs etc. The 16 K MCA card gives an economic, compact, and low power alternative for nuclear pulse spectroscopy use. (author)

  20. An angle encoder for super-high resolution and super-high accuracy using SelfA

    International Nuclear Information System (INIS)

    Watanabe, Tsukasa; Kon, Masahito; Nabeshima, Nobuo; Taniguchi, Kayoko

    2014-01-01

    Angular measurement technology at high resolution for applications such as in hard disk drive manufacturing machines, precision measurement equipment and aspherical process machines requires a rotary encoder with high accuracy, high resolution and high response speed. However, a rotary encoder has angular deviation factors during operation due to scale error or installation error. It has been assumed to be impossible to achieve accuracy below 0.1″ in angular measurement or control after the installation onto the rotating axis. Self-calibration (Lu and Trumper 2007 CIRP Ann. 56 499; Kim et al 2011 Proc. MacroScale; Probst 2008 Meas. Sci. Technol. 19 015101; Probst et al Meas. Sci. Technol. 9 1059; Tadashi and Makoto 1993 J. Robot. Mechatronics 5 448; Ralf et al 2006 Meas. Sci. Technol. 17 2811) and cross-calibration (Probst et al 1998 Meas. Sci. Technol. 9 1059; Just et al 2009 Precis. Eng. 33 530; Burnashev 2013 Quantum Electron. 43 130) technologies for a rotary encoder have been actively discussed on the basis of the principle of circular closure. This discussion prompted the development of rotary tables which achieve reliable and high accuracy angular verification. We apply these technologies for the development of a rotary encoder not only to meet the requirement of super-high accuracy but also to meet that of super-high resolution. This paper presents the development of an encoder with 2 21 = 2097 152 resolutions per rotation (360°), that is, corresponding to a 0.62″ signal period, achieved by the combination of a laser rotary encoder supplied by Magnescale Co., Ltd and a self-calibratable encoder (SelfA) supplied by The National Institute of Advanced Industrial Science and Technology (AIST). In addition, this paper introduces the development of a rotary encoder to guarantee ±0.03″ accuracy at any point of the interpolated signal, with respect to the encoder at the minimum resolution of 2 33 , that is, corresponding to a 0.0015″ signal period