WorldWideScience

Sample records for high resolution osl

  1. A reusable OSL-film for 2D radiotherapy dosimetry

    Science.gov (United States)

    Wouter, Crijns; Dirk, Vandenbroucke; Paul, Leblans; Tom, Depuydt

    2017-11-01

    Optical stimulated luminescence (OSL) combines reusability, sub-mm resolution, and a linear dose response in a single radiation detection technology. Such a combination is currently lacking in radiotherapy dosimetry. But OSL-films have a strong energy dependent response to keV photons due to a relative high effective atomic number (Z eff). The current work studied the applicability of a 2D OSL-film with a reduced Z eff as (IMRT/VMAT) dosimeter. Based on their commercial OSL-film experience, Agfa Healthcare N.V. produced a new experimental OSL-film for RT dosimetry. This film had a lower effective atomic number compared to the films used in radiology. Typical 2D dosimeter requirements such as uniformity, dose response, signal stability with time, and angular dependence were evaluated. Additionally, the impact of a possible residual energy dependence was assessed for the infield as well as the out-of-field region of both static beams and standard intensity modulated patterns (chair and pyramid). The OSL-film’s reusable nature allowed for a film specific absolute and linear calibration including a flood-field uniformity correction. The OSL-film was scanned with a CR-15X engine based reader using a strict timing (i.e. 4 min after ‘beam on’ or as soon as possible) to account for spontaneous recombination. The OSL-film had good basic response properties: non-uniformities  ⩽2.6%, a linear dose response (0-32 Gy), a linear signal decay (0.5% min-1) over the 20 min measured, and limited angular dependence  ⩽2.6%. Due to variations of the energy spectrum, larger dose differences were noted outside the central region of the homogenous phantom and outside both static and IMRT fields. However, the OSL-film’s measured dose differences of the IMRT patterns were lower than those of Gafchromic EBT measurements ([-1.6%, 2.1%] versus [-2.9%, 3.6%]). The current OSL-film could be used as a reusable high resolution dosimeter with read-out immediately after

  2. High-resolution OSL chronology of a sediment core from Lake Nam Co on the southern Tibetan Plateau: Comparison with radiocarbon dating

    Science.gov (United States)

    Long, Hao; Shen, Ji; Haberzettl, Torsten; Fuchs, Markus; Frechen, Manfred; Wang, Junbo

    2013-04-01

    Numerous studies on lake sediment cores from the Tibetan Plateau aimed to reconstruct spatial and temporal changes of the late Glacial and Holocene monsoon variations, which are characterized by fluctuations in precipitation and expansion of monsoonal air masses across the Plateau. Accurate and reliable dating of lacustrine deposits is of crucial importance in both the reconstruction of palaeolake and palaeoclimate evolution and the understanding of the mechanisms for climate changes, especially abrupt changes of regional-hemispheric hydrological circulation. Radiocarbon dating is the most commonly used method for establishing chronologies of lake sediments. However, 14C dating of such sediments could be problematic due to the lack of organic matter or a reservoir effect, which appears common in radiocarbon dating of lacustrine sediments from the Tibetan Plateau. In this study, ca. 10.5 m long core (NC core) was retrieved from the water depth of 93 m at Nam Co Lake, which is the second largest saline lake in China, located on the southern Tibetan Plateau. For this core, high-resolution samples (23 samples) were obtained for optically stimulated luminescence (OSL) dating. Quartz of fine-grain (4-11 μm) fraction were extracted from this samples for OSL dating, which is compared with the 14C chronology of NC core based on accelerator mass spectrometry (AMS) dating of bulk organic matter of 22 samples. The sample from the top of NC core was dated to approximate zero age, indicating the sediments bleached well before deposition. Luminescence behaviors of the study samples further confirmed the robustness of OSL ages. Comparison between OSL and 14C ages suggested that: (1) two kinds of ages are in agreement within error from top to 1.8 m, (2) from 1.8 m to the base of NC core, the 14C ages show a general trend to ca. 4 ka higher ages than the OSL ages. Although 14C dating overestimate the ages from 1.8 m to base, they still show the general trend in sedimentation rate

  3. High resolution optically stimulated luminescence dating of a sediment core from the southwestern Sea of Okhotsk

    DEFF Research Database (Denmark)

    Sugisaki, S.; Buylaert, J. P.; Murray, A. S.

    2012-01-01

    (D-e), with stimulation by both infrared and blue light. The suitability of the measurement procedure was confirmed using dose recovery tests. A high resolution record (similar to 2 OSL ages/m) identified clear sedimentation rate changes down the core. The OSL ages are significantly dependent......Optically stimulated luminescence (OSL) dating is now widely accepted as a chronometer for terrestrial sediment. More recently, it has been suggested that OSL may also be useful in the dating of deep-sea marine sediments. In this paper, we test the usefulness of high resolution quartz OSL dating...... in application to a 19 m marine sediment core (MR0604-PC04A) taken from the southwestern Sea of Okhotsk, immediately to the north of Hokkaido, Japan. Fine-grained quartz (4 to 11 mu m) was chosen as the dosimeter, and a single-aliquot regenerative-dose protocol was used for the determination of equivalent dose...

  4. Development of an Equipment for Measuring OSL

    International Nuclear Information System (INIS)

    Chung, Ki Soo; Choe, Hong Soo

    2010-05-01

    A measurement system optically simulated luminescence (OSL) and thermoluminescence (TL) is developed. The system is composed by stimulation light part assembled by 3 ea of high brightness blue LEDs, temperature control system which can be controlled from room temperature to 300 .deg. C and filter package for separation of OSL and stimulation light with GG-420 and U-340 optical filters. The system was tested using Al 2 O 3 C OSL samples and a typical OSL curves were obtained. In addition, several OSL curves from LiAlO 2 C (a candidate of new OSLD material) were obtained and analyzed. A new algorithm for analysis of OSL curve and software (TOLAnal, Windows based) is developed and tested

  5. High resolution OSL and post-IR IRSL dating of the last interglacialeglacial cycle at the Sanbahuo loess site (northeastern China)

    DEFF Research Database (Denmark)

    Yi, Shuangwen; Buylaert, Jan-Pieter; Murray, Andrew

    2015-01-01

    Northeastern China is located in the East Asian monsoon region; it is sensitive to both high and low latitude global climate systems. Loess deposits in the region have considerable potential as sensitive archives of past climate changes. However, research into loess deposition and climate change...... to have been a period of fast loess deposition at ~62 ka, perhaps indicative of winter monsoon intensification with a very cold and dry climate that lead to a serious desertification of dunefields in northeastern China. © 2015 Elsevier B.V. All rights reserved....... in this region is restricted by the lack of independent age control. In this study, coarse-grained quartz SAR OSL and K-feldspar post-IR infrared (IR) stimulated luminescence (post-IR IRSL; pIRIR290) methods have been used to date the Sanbahuo loess site in northeastern China. The quartz OSL characteristics...

  6. Natural and laboratory TT-OSL dose response curves: Testing the lifetime of the TT-OSL signal in nature

    International Nuclear Information System (INIS)

    Chapot, M.S.; Roberts, H.M.; Duller, G.A.T.; Lai, Z.P.

    2016-01-01

    This study compares natural and laboratory generated thermally transferred optically stimulated luminescence (TT-OSL) dose response curves (DRCs) for fine-grain quartz extracts from the Luochuan loess section in central China. Both DRCs saturate at high doses relative to the quartz OSL signal; the natural TT-OSL DRC saturates at about 2200 Gy and laboratory DRCs saturate at about 2700 Gy. However, the natural and laboratory TT-OSL DRCs deviate from one another at circa 150 Gy resulting in TT-OSL equivalent dose underestimation relative to palaeodoses expected from dose rates and independent age control. The lifetime of the TT-OSL signal at 10 °C, calculated from values of trap parameters E and s, is compared against the value for lifetime of the TT-OSL signal in nature at average burial temperature as determined from the age underestimation caused by deviation of the natural and laboratory generated DRCs. These two independent assessments of TT-OSL signal lifetime at Luochuan give similar values, suggesting that laboratory measurements of thermal stability reflect natural burial lifetimes and can potentially be used to correct TT-OSL ages for the difference between natural and laboratory dose response curves. - Highlights: • Natural and laboratory TT-OSL DRCs deviate at ∼150 Gy but saturate at higher doses. • TT-OSL signal lifetime at 10 °C calculated from measured E and s values is ∼180 ka. • TT-OSL signal lifetime at Luochuan estimated from the DRCs' deviation is ∼175 ka. • Natural and laboratory TT-OSL DRC deviation may be caused by low thermal stability. • Laboratory measurements of signal lifetime may be able to correct old TT-OSL ages.

  7. Study of combinations of TL/OSL single dosimeters for mixed high/low ionization density radiation fields

    International Nuclear Information System (INIS)

    Oster, L.; Druzhyna, S.; Orion, I.; Horowitz, Y.S.

    2013-01-01

    In this paper we discuss and compare the potential application of combined OSL/TL measurements using 6 LiF:Mg,Ti (TLD-600 is enriched of isotope 6 Li which has a high cross-section for the reaction with slow neutrons) or 7 LiF:Mg,Ti ( TLD-700 is enriched of 7 Li isotope) and TLD-100 (natural isotopic composition) detectors. The OSL/TL duel readout of LiF:Mg,Ti as an ionization density discriminator avoids some of the difficulties inherent to the various types of discrimination mixed-field passive dosimeters, and in addition has several advantages. The preferential excitation of OSL compared to TL following high ionization density (HID) alpha irradiation, naturally explained via the identification of OSL with the “two-hit” F 2 or F 3 center, whereas the major component of composite TL glow peak 5 is believed to arise from a ''one-hit'' complex defect. This evidence allows near-total discrimination between HID radiation and low-ionization density (LID) radiation. Beta and alpha particle irradiations were carried out with 90 Sr/ 90 Y (∼500 keV average energy) and 241 Am sources (4.7 MeV) respectively and neutron irradiations were carried out at the PTB (Germany) (E n = 5 MeV) and RARAF (Columbia University, USA) (E n = 6 MeV) accelerator facilities. The highest values of the FOM obtained was ∼30 for neutron/gamma discrimination and ∼110 for alpha/gamma discrimination using OSL/TL – peak 5 measurements in TLD-700. -- Highlights: ► The increased response of OSL compared to TL following HID irradiation is observed. ► This evidence is explained via the identification of OSL with the ''two-hit'' F2 centers. ► The potential application of combined OSL/TL in discrimination dosimetry is discussed. ► The values of FOM were 110 for alpha/gamma and 30 for neutron/gamma discrimination

  8. An environmental BeO-OSL dosimeter for emergency response

    International Nuclear Information System (INIS)

    Woda, Clemens; Kaiser, Jan Christian; Urso, Laura; Greiter, Matthias

    2012-01-01

    A conceptual design is presented to use measurements of localized absorbed dose in inner cities for production of high resolution maps of the radioactive contamination following a nuclear emergency or radiological attack. The doses are derived from luminescent detectors pre-fixed at places of high importance (e.g. public squares). For such an environmental dosimeter, BeO is used, which can be read out using optically stimulated luminescence (OSL). A suitable casing of black Perspex has been developed to give a sufficiently accurate estimate of the air kerma value at the detector position. The dosimeter is characterized according to light tightness, dose response and angular photon energy dependence. A short overview of the approach for map production is also given. - Highlights: ► An inexpensive, environmentally stable BeO based OSL dosimeter has been developed for emergency response. ► The detector enables fast readouts and shows highly favorable dosimetric properties. ► A conceptual design is described to produce maps of radioactive contamination from localized dose measurements in urban areas.

  9. Influence of thermal treatment on OSL regeneration in potassium chloride

    International Nuclear Information System (INIS)

    Majgier, Renata; Biernacka, Magdalena; Mandowski, Arkadiusz

    2016-01-01

    Optically stimulated luminescence (OSL) of pure analytical potassium chloride (KCl) prepared in two different forms (crystals and pellets) was studied. The occurrence of regeneration effect (self-renewal of the OSL signal) in the material was examined. The experiments using the variable delay OSL (VD-OSL) method were carried out. Performed measurements allowed to determine time scale of the phenomenon, as well as quantitative changes of regeneration depending on thermal treatment before and after irradiation. Significant increase of the OSL regeneration was noticeable for pellets after the application of the annealing before irradiation, while for crystals a substantial decrease of regeneration was observed. Preheating applied after irradiation caused that self-renewal of OSL signal was drastically reduced or completely suppressed depending on the form of KCl samples. - Highlights: • Optically stimulated luminescence (OSL) of potassium chloride (KCl) was studied. • The measurements were performed using the variable delay OSL method (VD-OSL). • It was found that regeneration of OSL intensity in KCl could be as high as 2000%. • Annealing caused reduction of OSL renewal for crystals and its increase for pellets. • Preheating after irradiation removed or significantly reduced the OSL regeneration.

  10. Component resolved bleaching study in natural calcium fluoride using CW-OSL, LM-OSL and residual TL glow curves after bleaching

    International Nuclear Information System (INIS)

    Angeli, Vasiliki; Polymeris, George S.; Sfampa, Ioanna K.; Tsirliganis, Nestor C.; Kitis, George

    2017-01-01

    Natural calcium fluoride has been commonly used as thermoluminescence (TL) dosimeter due to its high luminescence intensity. The aim of this work includes attempting a correlation between specific TL glow curves after bleaching and components of linearly modulated optically stimulated luminescence (LM-OSL) as well as continuous wave OSL (CW-OSL). A component resolved analysis was applied to both integrated intensity of the RTL glow curves and all OSL decay curves, by using a Computerized Glow-Curve De-convolution (CGCD) procedure. All CW-OSL and LM-OSL components are correlated to the decay components of the integrated RTL signal, apart from two RTL components which cannot be directly correlated with either LM-OSL or CW-OSL component. The unique, stringent criterion for this correlation deals with the value of the decay constant λ of each bleaching component. There is only one, unique bleaching component present in all three luminescence entities which were the subject of the present study, indicating that each TL trap yields at least three different bleaching components; different TL traps can indicate bleaching components with similar values. According to the data of the present work each RTL bleaching component receives electrons from at least two peaks. The results of the present study strongly suggest that the traps that contribute to TL and OSL are the same. - Highlights: • A component resolved bleaching study was attempted to CaF_2:N in terms of CW-OSL, LM-OSL and RTL. • Bleaching decay constants originating from different TL peaks yield overlapping values. • Three to five individual components were used in order to describe the bleaching behavior in all luminescence entities. • There is only one, unique bleaching component present in all three luminescence entities.

  11. The TL and OSL study of hydroxyapatites for dosimetric applications

    International Nuclear Information System (INIS)

    Alencar, Marcus A. Vallim de

    2009-01-01

    The hydroxyapatite, the principal mineral component of the bone and tooth enamel, is one of the dosimetric materials that has distinguished itself in the high dose and accidents dosimetry, as well as in the dating, for the Electron Paramagnetic Resonance (EPR) technique. For this reason, the hydroxyapatite could also be used as Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) dosimeter in the dosimetry of high doses and accidents, and also in the archaeological and geological dating. This work presents a brief study of the TL and OSL behaviour of the B type synthetic carbonated hydroxyapatite, observing the possibility to use this material in TL and OSL dosimetry. The samples were irradiated to a dose of 100 Gy and 1000 Gy, and the TL and OSL measurements were obtained by the RISOE TL/OSL reader, model TL/OSL-DA-15B. The first results demonstrate the presence of three peaks in the TL glow curve in the temperatures of 100 deg C, 150 deg C and 280 deg C. The synthetic carbonated hydroxyapatite also presents an OSL signal when the sample is stimulated with blue light and a small OSL signal for stimulation with infrared light (IR). These results indicate the possibility of this synthetic carbonated hydroxyapatite to be used as dose indicator material using the TL and OSL techniques. (author)

  12. OSL at elevated temperatures: Towards the simultaneous thermal and optical stimulation

    International Nuclear Information System (INIS)

    Polymeris, George S.

    2015-01-01

    In routine OSL dating measurements, a preheat procedure at high temperatures is used to empty the shallow traps. Thus no contribution from shallow traps was expected as each OSL measurement is subsequently performed at moderately high temperatures, around 110–125 °C. The present work attempts to consider the OSL measurements performed at elevated temperatures without any previous preheat as a case of simultaneous thermal and optical stimulation of the same trap. Towards this direction, a set of proposed equations is derived for all three different cases of optical stimulation modes, namely CW-OSL, LM-OSL as well as PS-LM-OSL. According to these equations, indicative features of thermally activated OSL processes are expected, such as the steepening of CW-OSL decay curves as either stimulation temperature or intensity increases, as well as the shifting of the stimulation time of the maximum intensity for both LM-OSL and PS-LM-OSL curves towards shorter times with increasing temperatures. Experimentally, specific measurement sequences after varying stimulation temperature and/or intensity were applied in order to estimate the values of associated trap parameters, such as activation energy and photo-ionization cross-section. Experimental OSL data from a milky natural quartz sample stand in good agreement of these theoretical considerations in the case of 110 °C TL peak and the intense OSL component C 2 monitored at RT. - Highlights: • OSL at elevated temperatures without preheat results from two simultaneous stimulation modes. • Equations were derived assuming of linear superposition of two stimulation modes. • Data for 110 °C TL peak and OSL C 2 at RT stand in agreement with these equations. • Results verify the linear superposition of the two stimulation modes

  13. A simple transformation for converting CW-OSL curves to LM-OSL curves

    DEFF Research Database (Denmark)

    Bulur, E.

    2000-01-01

    A simple mathematical transformation is introduced to convert from OSL decay curves obtained in the conventional way to those obtained using a linear modulation technique based on a linear increase of the stimulation light intensity during OSL measurement. The validity of the transformation...... was tested by the IR-stimulated luminescence curves from feldspars, recorded using both the conventional and the linear modulation techniques. The transformation was further applied to green-light-stimulated OSL from K and Na feldspars. (C) 2000 Elsevier Science Ltd. All rights reserved....

  14. Emergency OSL dosimetry with commonplace materials

    International Nuclear Information System (INIS)

    Sholom, S.; McKeever, S.W.S.

    2014-01-01

    Several commonplace materials were studied as possible emergency optically stimulated luminescence (OSL) dosimeters. The materials included: paper currency (banknotes) and coins of different denomination and from different countries; plastic cards of different types (credit and debit cards, driver's license cards, membership cards, etc.), parts and details of clothing and shoes as well as samples of different fabrics. The samples displayed significant variability in their OSL properties. They differed in the intensity of the initial ‘native’ signal; the bleaching time of the OSL signal; the sensitivity to light of different wavelengths; the fading rate of OSL signals, etc. Procedures of OSL analysis were proposed to account for this variety. Values of the minimum measurable dose (MMD) were below 2 Gy for most tested samples if OSL measurements were conducted within one week of exposure and the samples were kept in dark since exposure (except samples of shoes that were kept under environmental light). The OSL signals in banknotes appear to originate from compounds containing aluminum, silicon, calcium and titanium – these elements were detected using X-ray microanalysis. For coins, the source of the OSL signals is speculated to be small particles of quartz, which were detected on the coins' surfaces. The X-ray microanalysis spectra from fabrics and shoes revealed sodium, aluminum, titanium, iron and nickel as elements that appeared to be responsible for the radiation sensitivity of those samples. It was concluded that, under certain constrained circumstances, paper and metallic money, personal plastic cards, clothing and shoes could be used as emergency OSL dosimeters in triage applications. - Highlights: • Money, plastic cards, clothing and shoes were studied as emergency OSL dosimeters. • Values of the minimum measurable doses were below 2 Gy for most tested samples. • Tested materials could be used as emergency OSL dosimeters in triage applications

  15. Study of the OSL response of the CaF2:Dy (TLD-200) dosimeter

    International Nuclear Information System (INIS)

    Medeiros, Beatriz M.; Alencar, Marcus A.V. de

    2013-01-01

    The OSL dosimetry has become, in recent years, a successful technique in personal and environmental dosimetry due to high luminescence efficiency, excellent reproducibility, fast readout of signal and repeated and successive OSL measurements of the same dosimeter. Another factor that contributes to the increased use of OSL dosimetry is the use of the aluminum oxide doped with carbon (Al 2 O 3 :C) as dosimeter. Developed initially as thermoluminescent dosimeter, the Al 2 O 3 :C has an excellent OSL sensitivity, high efficiency, good linearity, low or no fading and excellent stability with respect to environmental conditions. However, the OSL dose response for aluminum oxide is linear only for low doses. For intermediate doses (doses in radiotherapy), the response is supralinear. For the values of high doses used in the processes of food irradiation and sterilization of surgical materials, the OSL signal of the aluminum oxide already saturated. Furthermore, the degree of supralinearity and the saturation value vary from sample to sample (∼ 30-300 Gy). Therefore, the use of aluminum oxide as OSL dosimeter is inappropriate in radiotherapy and in the irradiation industrial processes. The objective of this work is the study of the OSL properties of other dosimetric materials irradiated with values of intermediate and high dose to verify the applicability of the OSL dosimetry in radiotherapy and in the processes of food irradiation and sterilization of medical materials. The dosimetric material used in this work is the calcium fluoride doped with dysprosium (CaF 2 :Dy) produced by Harshaw and known commercially as TLD-200. The results demonstrate that the CaF 2 :Dy has OSL signal and the OSL dose response is linear in the range of 10 Gy to 300 Gy. Therefore, the dosimetry OSL with this dosimeter can be used in the evaluation of doses of the order of dozens to hundreds of grays. (author)

  16. Tl and OSL on diopside crystal

    International Nuclear Information System (INIS)

    Cano, N.F.; Watanabe, S.; Mittani, J.C.R.; Yukihara, E.G.

    2006-01-01

    The diopside with chemical composition CaMgSi 2 O 6 is part of an important solid solution series of the pyroxene group. The mineral is commonly found in meteorites and it is an important rock forming mineral of medium and high grade metamorphic rocks which are rich in calcium. In the bibliography it is possible to found several studies on electron spin resonance (ESR), reflectance, etc. but not on thermoluminescence (TL) or optically stimulated luminescence (OSL). In the present work we studied diopside TL and OSL behaviour on natural and natural irradiated samples. The sample used in our study is a white coloured diopside provided by Mineracao Sao Judas located in Sao Paulo, Brazil. The X-Ray Fluorescence technique has shown high concentrations of SiO 2 (55.81 % mol), CaO (23.47 % mol), MgO (18.03 % mol), Al 2 O 3 (1.56 % mol), Fe 2 O 3 (0.53 % mol), K 2 O (0.44 % mol), TiO 2 (0.065 % mol), P 2 O 5 (0.026 % mol), and MnO (0.013 % mol). TL measurements on natural samples show four TL peaks at 160, 260, 360, and 450 C. After beta-irradiation an increment mainly in the low temperature peaks is observed. As for OSL measurements, low OSL signal was observed on natural samples using blue light stimulation and UV detection. The intensity of the signal was observed to increase with the irradiation dose. (Author)

  17. Alpha efficiency under TL and OSL - A subtraction technique using OSL and TL to detect artificial irradiation

    International Nuclear Information System (INIS)

    Zink, A.J.C.; Dabis, S.; Porto, E.; Castaing, J.

    2010-01-01

    With the development of thermoluminescence (TL) and optically stimulated luminescence (OSL) to determine the authenticity of old ceramics, forgers use artificial irradiation by gamma ray to age modern productions. Besides fraudulent action, objects can be exposed to various sources of X-rays (e.g. radiography, security control at airports). For all these reasons, the determination of artificial irradiation is an important topic for dating art objects. The main technique to identify artificial irradiations is the subtraction technique. It is based on the fact that alpha efficiency varies according to the luminescence technique (fine grain, coarse grains, predose, OSL). Having observed a rather significant difference of alpha efficiency for TL and OSL, we propose a new subtraction technique using OSL and TL of fine grains.

  18. Dosimetry in the multi kilo-Gray range using optically-stimulated luminescence (OSL) and thermally-transferred OSL from quartz

    International Nuclear Information System (INIS)

    Burbidge, C.I.; Cabo Verde, S.I.; Fernandes, A.C.; Prudencio, M.I.; Botelho, M.L.; Dias, M.I.; Cardoso, G.

    2011-01-01

    This study explores the potential for using photon-stimulated luminescence of quartz grains to retrospectively evaluate multi-kGy gamma radiation doses. Subsamples from two ceramic tiles were given 60 Co gamma doses of 1, 3, 5, 15 and 30 kGy (nominal), accompanied by PMMA dosimeters and quartz grains from a geological sample known to exhibit thermally-transferred optically-stimulated luminescence (TTOSL). Following gamma irradiation, quartz grains were prepared from each subsample. OSL and TTOSL signals were measured for different preheat temperatures, and following re-irradiation with beta doses designed to equal the nominal gamma doses. OSL responses to 10 Gy beta test doses were measured following each cycle of high dose irradiation. Gamma doses were predicted from the beta responses, to evaluate the effectiveness of retrospective dose evaluation for different signal integrals, preheat combinations, and dose intervals. The use of linear modulation limited maximum OSL signal levels to 1.5 x 10 6 cps without reducing detector sensitivity, for the measurement of smaller TTOSL signals. The dosimetric behaviour of the three samples differed significantly: the best results were obtained from the pre-prepared geological quartz. OSL signals evident at short stimulation times, which are conventionally used for dosimetry and dating, did not in general appear appropriate for dosimetry in the range of doses examined. They exhibited dose response characteristics that were highly preheat dependant and variable in form between samples, which contained rapidly saturating and/or non-monotonic components. Higher preheats, up to 300 o C, preferentially removed OSL and TTOSL signals evident at longer stimulation times: those that remained yielded growth in signal with dose to approximately 10 kGy, but the accuracy of retrospective dose determinations was variable. TTOSL signals evident at short stimulation times increased proportionally with dose when 300 o C preheats were used, up

  19. Correlation between TL and OSL properties of CaF2:N

    International Nuclear Information System (INIS)

    Polymeris, George S.; Kitis, George; Tsirliganis, Nestor C.

    2006-01-01

    Natural CaF 2 is very well known thermoluminescent (TL) material, since it has been extensively used as a dosimeter. Its basic advantage is the exhibited high TL sensitivity. In the present work, the optically stimulated luminescence (OSL) sensitivity of this material was studied by exposing it to environmental radiation for time intervals of few hours up to a few days, and was found to be very high. By analyzing the TL glow curves and the OSL decay curves into their individual glow-peaks and components respectively, a relation between specific glow-peaks and OSL components was established. An intense thermal transfer effect occurring during optical stimulation at high temperature was observed and an explanation is offered according to existing models

  20. Implementation of a OSL dosimetry laboratory at IRD/CNEN-BR

    International Nuclear Information System (INIS)

    Moura, Jose; Alencar, Marcus A. Vallim de; Mauricio, Claudia L.P.; Hunt, John

    2005-01-01

    The optically stimulated luminescence (OSL) it is a phenomenon characterized by the luminous emission of an insulating material or semiconductor, during your exhibition to the light, after it being previously exposed to the ionizing radiation. This phenomenon has been used more and more in the dosimetry of the ionizing radiations, why the intensity OSL of some materials is proportional to the absorbed dose in these. The processes OSL and thermoluminescence (TL) they only differ in the stimulation form for light emission. One of the advantages of the OSL process in relation to the traditional technique of TL dosimetry is the no complete destruction of the information of the absorbed dose in the material during the reading. Following this world tendency, the External Individual Monitoring Service of the Institute of Radioprotection and Dosimetry (SEMEX/IRD) implemented the OSL dosimetry laboratory. The acquired reader was the reader model LAUGHTER TL/OSL-GIVE-15B/C. With that reader it is possible to do readings TL and OSL. After the installation of the equipment in a darkroom with temperature and humidity controlled, they were made the preliminary tests with the equipment and the laboratory became operational. After this first stage, they were initiate the studies with the Al 2 O 3 :C dosimeters by Harshaw under the denomination TLD 500. The reading parameters and thermal treatment were optimized to study the applicability of OSL technique with the TLD 500 dosimeter for the use in environmental monitoring. It was also verified the linearity of the system for high doses (10 mGy-1 Gy) seeking your use in radiotherapy, as well as the effect of the thermal treatment in the OSL signal of the Al 2 O 3 :C dosimeter. The results prove the possibility of use of this system in environmental monitoring. The reproductivity of the system for the air kerma value of 100 mGy, considering a degree of confidence of 95%, was to 4,8% for OSL readings and 5,6% for TL. In the two cases

  1. Utilisation of OSL from table salt in retrospective dosimetry

    International Nuclear Information System (INIS)

    Fujita, Hiroki; Jain, Mayank; Murray, Andrew S.

    2011-01-01

    Common salt (NaCl) has previously been suggested for use in dose estimation in accident dosimetry. In this study, we investigated the optically stimulated luminescence (OSL) and violet thermoluminescence (VTL) characteristics of 'Aji-Shio' (Ajinomoto), a Japanese commercial salt. A comparison of OSL and TL signals allowed identification of common source traps. The initial OSL signal contained a dominant thermally unstable component, which necessitated prior heat treatment. Based on these luminescence characteristics, a single-aliquot regenerative-dose (SAR) OSL protocol was modified and tested. The protocol worked very well for six types of salt, but not for four other types of salt. A minimum detection limit of ∼15 mGy was estimated using the OSL protocol; this is lower than the value obtained from other forms of OSL retrospective dosimetry and lower than that obtained using electron spin resonance (ESR) dosimetry. It was concluded that the OSL from Japanese commercial salt could be used successfully to derive precise estimates of accident dose. (author)

  2. TL and OSL dosimetric properties of Opal gemstone for gamma radiation dosimetry

    International Nuclear Information System (INIS)

    Antonio, Patrícia L.; Gronchi, Claudia C.; Oliveira, Raquel A.P.; Khoury, Helen J.; Caldas, Linda V.E.

    2016-01-01

    In this work, the response of the natural material Opal was studied in relation to its thermoluminescence (TL) and optically stimulated luminescence (OSL), after exposure to the gamma radiation of a "6"0Co source. The structure of the powdered Opal was verified using the X-ray diffraction, scanning electronic microscopy and energy-dispersive X-ray spectroscopy techniques. The material, in its stone form, was turned into powder and mixed to Teflon (also in powder) in three different concentrations, and then pellets were manufactured. The aim of this work was to evaluate the response of these pellets in high-doses of gamma radiation beams, and to observe their possible application as dosimeters, using the TL and OSL techniques. The dosimetric properties of the samples were analyzed by means of different tests, as: TL emission curves and OSL signal decay curves, reproducibility of TL and OSL response, minimum detectable dose, TL and OSL dose–response curves (5 Gy–10 kGy), and fading. The results obtained in this work, for the TL and OSL phenomena, demonstrated that the pellets of Opal + Teflon present an adequate performance e possibility of use as dosimeters in beams of high-dose gamma radiation. - Highlights: • The XRD, SEM and EDX techniques were used to investigate powdered Opal. • Pellets of three different concentrations of Opal and Teflon were studied. • The dosimetric properties of the Opal + Teflon pellets were verified. • TL and OSL techniques were used to analyze the characteristics of the pellets. • Pellets of concentration of 2:1 (Opal:Teflon) presented the most adequate results.

  3. Using OSL dating to quantify rates of Earth surface processes

    Science.gov (United States)

    Rhodes, E. J.; Rittenour, T. M.

    2010-12-01

    In Optically Stimulated Luminescence (OSL), the dating signal is reset when mineral grains are exposed to light or heat, and gradually rebuilds during subsequent burial by interaction with ionising radiation. Quartz and feldspar provide useful OSL signals demonstrating rapid signal reduction in only seconds of light exposure. Age estimates ranging from under 1 year to around 200,000 years can be determined for a wide range of sedimentary contexts, including dunes, marine deposits, fluvial and glacial environments, and recent developments provide the framework for low temperature thermochronometric applications on timescales comparable with rapid climate fluctuations. In this presentation, we explore the range of applications for determining rates of Earth surface processes using OSL. We examine technical limitations, and provide a framework for overcoming current difficulties experienced in several specific regions and contexts. We will focus on OSL dating applications to glacigenic and fluvial records, along with use of the technique in tectonic and paleoseismic contexts. In many ways, these represent the most challenging environments for OSL; rapid high energy deposition is associated with incomplete signal zeroing, and the characteristics of quartz in many of these environments make it difficult to derive precise age estimates using this mineral. We will introduce innovative methods to overcome these limitations, both existing and those under development.

  4. BeOSL system for personal dosimetry : dosimetric characteristics and practical application; Sistema BeOSL para dosimetria personal : caracteristicas dosimetricas y la aplicacion practica

    Energy Technology Data Exchange (ETDEWEB)

    Mende, E. [Helmholtz Zentrum Munchen, German Research Center for Environmental Health, Working Group Engineering, D-85764 Neuherberg (Germany)

    2015-10-15

    Full text: BeOSL system of Dosimetric s is very easy to use, assimilate and maintain. Our dosimeter defines a milestone in the supervision of personal equivalent dose of Hp (10) and Hp (0.07) it covers the range of total energy of 16 KeV to 10 MeV. For this energy range is exceptional in its energy dependence for official personal dosimetry. The BeOSL system consists of two modules, one of them is the BeOSL reader that measures the radiation exposure using the latest technology, optically stimulated luminescence (OSL). The reading is extremely fast; it does not require consumables such as nitrogen or other. The detector material is beryllium oxide (Be O); this is an OSL material tissue equivalent and therefore is ideal for personal dosimetry. The BeOSL technology allows multiple readings of the dosimeter (re-read) to verify the dose or archive the dosimeter. One of the biggest advantages of BeOSL system is its modular concept allows the system to run as a manual solution or as a complete automated robotic system, which can be filled with up to 5,000 dosimeters as bulk cargo. (Author)

  5. OSL and IRSL characteristics of quartz and feldspar from southern California, USA

    International Nuclear Information System (INIS)

    Lawson, Michael J.; Roder, Belinda J.; Stang, Dallon M.; Rhodes, Edward J.

    2012-01-01

    Southern California comprises of a wide range of diverse landscapes and environments, from high mountains with glacial and periglacial sediments to deserts with large sand dunes, extensive alluvial fans and ephemeral playas. Highly active tectonic processes has exposed ancient (c. 2 Ga) plutonic and metamorphic basement from deep within the crust, while similar Palaeozoic, Mesozoic and Cenozoic rocks are also common. A rich array of volcanic lithologies extending into the late Quaternary complement many thick sedimentary sequences that formed in equally diverse ancient environments typical of an accreting active continental margin. In some locations, notably in the Coachella Valley close to Palm Springs and the Salton Sea, low OSL sensitivity and poor characteristics restrict the application of the quartz SAR protocol to date late Pleistocene and Holocene fluvial sediments. In other locations such as the Malibu coastline, high sensitivity of the quartz OSL signal is observed, despite local source rocks being dominated by volcanic lithologies. Problems of poor quartz characteristics, along with uncertainty in predicting quartz OSL behavior for future dating campaigns poses a significant problem for projects, in particular for neotectonic contexts. While K-feldspar has been used extensively to date eolian and fluvial sediments in southern California, little information regarding signal stability is available. We explore the characteristics of both quartz and feldspar sub-samples from eolian, fluvial, lacustrine environments, in order to help develop mineral selection criteria for optical dating applications and clarify these issues. The importance of radiation quenching in quartz grains recently eroded from bedrock and the role of fires in enhancing OSL sensitivity are considered. The relative bleachability of quartz and feldspar fractions, along with thermal stability considerations is discussed. A simple test for quartz OSL signal contamination based on thermal

  6. OSL Age Determination of the Hearths in a Bronze Age Dwelling Site by using Bayesian Statistics

    International Nuclear Information System (INIS)

    Kim, Myung Jin; Yang, Hye Jin; Hong, Duk Geun

    2011-01-01

    OSL dating for three hearths having the sequence of use and discard in No. 29 and 29-1 dwelling sites at Sogol cultural site was carried out. Resulting from the deconvolution of natural CW-OSL decay curve and thermal zeroing test, it was turned out that OSL signal was entirely composed of the heat- and light-sensitive fast component with high photoionization cross-section and all quartz OSL signals were thermally bleached under 300 .deg. C which is the minimum temperature related to heating and cooking in Bronze age. After dose recovery test and plateau test, paleodose of each hearth sample was evaluated by using SAR method, and OSL age was determined from the ratio of paleodose to annual dose rate. For the purpose of the precision improvement of OSL age, Bayesian statistics was applied to each hearth's age and the archaeological sequence information. Finally, it could be concluded to the accurate use period of each hearth from the resultant OSL ages

  7. OSL Age Determination of the Hearths in a Bronze Age Dwelling Site by using Bayesian Statistics

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myung Jin [Neosiskorea Co. Ltd., Seoul (Korea, Republic of); Yang, Hye Jin [Baekje Cultural Properties Research Institute, Gongju (Korea, Republic of); Hong, Duk Geun [Kangwon National University, Chuncheon (Korea, Republic of)

    2011-06-15

    OSL dating for three hearths having the sequence of use and discard in No. 29 and 29-1 dwelling sites at Sogol cultural site was carried out. Resulting from the deconvolution of natural CW-OSL decay curve and thermal zeroing test, it was turned out that OSL signal was entirely composed of the heat- and light-sensitive fast component with high photoionization cross-section and all quartz OSL signals were thermally bleached under 300 .deg. C which is the minimum temperature related to heating and cooking in Bronze age. After dose recovery test and plateau test, paleodose of each hearth sample was evaluated by using SAR method, and OSL age was determined from the ratio of paleodose to annual dose rate. For the purpose of the precision improvement of OSL age, Bayesian statistics was applied to each hearth's age and the archaeological sequence information. Finally, it could be concluded to the accurate use period of each hearth from the resultant OSL ages.

  8. Characterization of Al{sub 2}O{sub 3}:C dosemeters for photon dosimetry using OSL technique; Caracterizacao de dosimetros de Al{sub 2}O{sub 3}:C para dosimetria de fotons utilizando a tecnica OSL

    Energy Technology Data Exchange (ETDEWEB)

    Villani, D.; Almeida, S.B.; Campos, L.L., E-mail: dvillani@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2016-07-01

    The optically stimulated dosimetry (OSL) has gained prominence in clinical and academic applications in Brazil. In this paper, we present results of the characterization OSL dosimeters Al{sub 2}O{sub 3}:C (TLD-500) manufactured by Rexon™ Components and TLD Systems in a RISØ reader, model TL/OSL-DA-20 for dosimetry of high-energy photon beams. All reader parameters, and its variations were evaluated. (author)

  9. Properties of lithium aluminate for application as an OSL dosimeter

    International Nuclear Information System (INIS)

    Twardak, A.; Bilski, P.; Marczewska, B.; Lee, J.I.; Kim, J.L.; Gieszczyk, W.; Mrozik, A.; Sądel, M.; Wróbel, D.

    2014-01-01

    Several samples of undoped and carbon or copper doped lithium aluminate (LiAlO 2 ) were prepared in an attempt to achieve a material, which can be applicable in optically stimulated luminescence (OSL) dosimetry. All investigated samples are highly sensitive to ionizing radiation and show good reproducibility. The undoped and copper doped samples exhibit sensitivity several times higher than that of Al 2 O 3 :C, while sensitivity of the carbon doped samples is lower. The studied samples exhibit significant fading, but dynamics of signal loss is different for differently doped samples, what indicates a possibility of improving this characteristic by optimizing dopant composition. - Highlights: • OSL properties of lithium aluminate for personal dosimetry. • Doping influence on OSL fading of lithium aluminate. • Application of lithium aluminate in thermal neutron measurements

  10. The origin of the medium OSL component in West Australian quartz

    International Nuclear Information System (INIS)

    Wang, X.L.; Du, J.H.; Adamiec, G.; Wintle, A.G.

    2015-01-01

    Optically stimulated luminescence (OSL) of a coarse-grained sedimentary quartz from West Australia was investigated. Observations of OSL and TL (thermoluminescence) were made following a series of experiments using different heating and optical bleaching conditions, and with optical stimulation at several different temperatures. Analysis of the fast and medium OSL components suggests that the medium OSL component observed after heating at 260 °C is a by-product of the production of the fast component, and both of them have as their original source the 325 °C TL trap. During fast OSL production following irradiation and preheating, some of the electrons evicted into the conduction band are re-trapped in an intermediate trap corresponding to the 170 °C TL peak; from here they are instantaneously stimulated to give rise to the medium OSL signal when the blue light stimulation is switched on, and subsequently result in the residual recuperated TL after the blue light is switched off. The kinetic properties of the medium OSL component are determined by the properties of both the 170 °C and 325 °C TL traps in contrast to the conventional interpretation of the medium component being derived from an independent source trap. Therefore, the 170 °C TL trap also plays unexpected roles in quartz OSL production with elevated stimulation temperatures (e.g. 125 °C or 130 °C, currently used for OSL dating), while the 110 °C TL trap and its influences are being avoided. - Highlights: • Quartz medium OSL component is a by-product of fast OSL component production. • Medium component is mediated by the 170 C TL peak. • Phototransfer is responsible for the medium OSL

  11. More on the TR-OSL signal from BeO ceramics

    International Nuclear Information System (INIS)

    Bulur, Enver

    2014-01-01

    Time Resolved Optically Stimulated Luminescence (TR-OSL) from BeO ceramics was investigated using blue (445 nm) and near-IR light (852 nm) for stimulation. Stimulation spectrum of the TR-OSL signal – as measured in the interval 700 to 420 nm- was observed to increase monotonically with the decreasing stimulation wavelength. In addition to the “fast” and “slow” components observed with blue light stimulation, IR stimulated TR-OSL spectra of irradiated BeO ceramics were observed to have two components with average lifetimes around ∼2.5 μs and ∼17 μs. Emission spectra of the both IR stimulated TR-OSL components were observed to have a broad emission band peaking around 330 nm. Thermal stability of the IR stimulated TR-OSL signal was studied by making preheating experiments in the range from 100 °C to 190 °C. It was observed that the IR stimulated OSL signal is stable up to ∼150 °C and decay afterwards. Radiation dose response of the IR stimulated luminescence signal was obtained in the range from 5 to 500 Gy. Both blue and IR stimulated TR-OSL signals grew up to 100 Gy and exhibited saturation for higher doses. Additionally, measurement temperature dependence of the components was also investigated and for the ∼2 μs component thermal assistance with activation energy around 0.16 eV was observed. It seems that the fast component of the blue stimulated TR-OSL component can be correlated to the ∼2 μs IR stimulated TR-OSL component. - Highlights: • IR Stimulated Time-Resolved OSL from BeO was studied. • Two components with lifetimes ∼2 and ∼17us were observed. • IR stimulated TR-OSL signal is found to be stable up to 150 °C. • Thermal quenching energy of the 2us component was found as 0.16 eV

  12. Investigation of TL, OSL and PTTL properties of Mg2SiO4:Tb dosimeters

    International Nuclear Information System (INIS)

    Oguz, K. F.; Goekce, M.; Karali, T.; Harmansah, C.

    2010-01-01

    In this study thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of Mg 2 SiO 4 :Tb in the form of sintered pellets were investigated. Mg 2 SiO 4 :Tb is a recently developed dosimetric material which offers high sensitivity for TL and OSL in dosimetric applications. Thermoluminescence glow curve of Tb doped Mg 2 SiO 4 samples show a glow peak at about 200 degree Celsius with two small peaks at about 275 and 330 degree Celsius, respectively. OSL experiments showed that blue light (470 nm) is six times more efficient than green light (532 nm) to stimulate the OSL emission. The aim of this study was to determine the TL and OSL fading properties of Mg 2 SiO 4 : Tb using OSL and TL methods. In addition, PTTL properties of the Mg 2 SiO 4 : Tb was investigated by using blue LEDs, UV lamp and blue laser. Investigations on the fading properties also showed that the TL signal fades % 10 in a period of 1 month and OSL signal fades % 10 in a period of 3 month, which then the signal remains relatively stable for longer periods.

  13. Sample dependent correlation between TL and LM-OSL in Al2O3:C

    International Nuclear Information System (INIS)

    Dallas, G.I.; Polymeris, G.S.; Stefanaki, E.C.; Afouxenidis, D.; Tsirliganis, N.C.; Kitis, G.

    2008-01-01

    Al 2 O 3 :C single crystals are known to exhibit different, sample dependent, glow-curve shapes. The relation between the Thermoluminescence (TL) traps and the linear modulated optically stimulation luminescence (LM-OSL) traps is of high importance. In the present work a correlation study is attempted using 23 single crystals with dimensions between 400 and 500μm. The correlation study involved two steps. In the first step, both TL glow curves and LM-OSL decay curves are deconvoluted and a one-to-one correlation between TL peaks and LM-OSL components is attempted. In the second step the TL glow-curves are corrected for thermal quenching, the corrected curves are deconvoluted and a new correlation between TL and LM-OSL individual components is performed

  14. Remote TL and OSL for asteroid and meteorite study

    International Nuclear Information System (INIS)

    Takaki, Shunji; Ikeya, Motoji; Yamanaka, Chihiro

    1997-01-01

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) of the Allende meteorite have been studied using infrared CO 2 laser light as a heat source and He-Ne laser light to excite the material, respectively from a long distance. New techniques of remote TL (R-TL) and remote OSL (R-OSL) have been developed for future remote dating from a long distance in a planetary survey. The upper limits of the distance for R-TL and R-OSL were estimated using the laboratory TL signal of the meteorite peaking at 320 o C: about 400 photons s -1 for the R-TL and 60 photons s -1 for R-OSL at a distance of 1 km using a laser beam with the divergence of 0.1 mrad at powers of 100 and 1 W, respectively. An age limit of 10 5 or 10 6 years due to the signal saturation and the objects heterogeneity, as expected from previous studies, may make the asteroid survey difficult but would still help to investigate the surface activities of icy planets and satellites in outer planet worlds. (author)

  15. BeOSL system for personal dosimetry : dosimetric characteristics and practical application

    International Nuclear Information System (INIS)

    Mende, E.

    2015-10-01

    Full text: BeOSL system of Dosimetric s is very easy to use, assimilate and maintain. Our dosimeter defines a milestone in the supervision of personal equivalent dose of Hp (10) and Hp (0.07) it covers the range of total energy of 16 KeV to 10 MeV. For this energy range is exceptional in its energy dependence for official personal dosimetry. The BeOSL system consists of two modules, one of them is the BeOSL reader that measures the radiation exposure using the latest technology, optically stimulated luminescence (OSL). The reading is extremely fast; it does not require consumables such as nitrogen or other. The detector material is beryllium oxide (Be O); this is an OSL material tissue equivalent and therefore is ideal for personal dosimetry. The BeOSL technology allows multiple readings of the dosimeter (re-read) to verify the dose or archive the dosimeter. One of the biggest advantages of BeOSL system is its modular concept allows the system to run as a manual solution or as a complete automated robotic system, which can be filled with up to 5,000 dosimeters as bulk cargo. (Author)

  16. Application of pulsed OSL to polymineral fine-grained samples

    International Nuclear Information System (INIS)

    Feathers, James K.; Casson, M. Aksel; Schmidt, Amanda Henck; Chithambo, Makaiko L.

    2012-01-01

    Pulsed OSL is applied to nine fine-grained sediment samples from Sichuan province, China, using stimulating pulses of 10 μs on and 240 μs off, with an infrared exposure prior to each OSL measurement. Comparison of fading rates between pulsed and non-pulsed signals, the latter also obtained with a preceding IR exposure, shows that fading is significant for mainly the non-pulsed signals. Presence of a pulsed IRSL and the magnitudes of b-value to correct for lower alpha efficiency suggest that pulsing does not fully remove a significant feldspar signal, only a fading component. Comparison with ages of quartz extracts shows that pulsed OSL ages are consistent, while CW-OSL ages are slightly older and CW-IRSL ages are much older. The older ages suggest a less well-bleached feldspar component.

  17. Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters

    International Nuclear Information System (INIS)

    Sanchez, R.M.; Vano, E.; Fernandez, J.M.; Ginjaume, M.; Duch, M.A.

    2014-01-01

    The purpose of this paper is to test the appropriateness of OSL and electronic dosemeters to estimate eye lens doses at interventional cardiology environment. Using TLD as reference detectors, personal dose equivalent was measured in phantoms and during clinical procedures. For phantom measurements, OSL dose values resulted in an average difference of 215 % vs. TLD. Tests carried out with other electronic dosemeters revealed differences up to ±20 % versus TLD. With dosemeters positioned outside the goggles and when TLD doses were >20 μSv, the average difference OSL vs. TLD was 29 %. Eye lens doses of almost 700 μSv per procedure were measured in two cases out of a sample of 33 measurements in individual clinical procedures, thus showing the risk of high exposure to the lenses of the eye when protection rules are not followed. The differences found between OSL and TLD are acceptable for the purpose and range of doses measured in the survey (authors)

  18. Performance of OSL dosimeters in clinical beams from mammography; Desempenho de dosimetros OSL em feixes clinicos empregados na mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Caio V.; Cabete, Henrique V.; Alves, Fatima F.R.; Pires, Silvio R.; Medeiros, Regina B.; Freitas, Marcelo B. [Universidade Federal de Sao Paulo (HSP/EPM/UNIFESP), SP (Brazil). Escola Paulista de Medicina; Malthez, Anna Luiza M.C. [Universidade Estadual de Campinas (CPG/FEEC/UNICAMP), Campinas, SP (Brazil). Faculdade de Engenharia Eletrica e de Computacao. Programa de Pos-Graduacao

    2015-08-15

    The search for the relationship between dose and mammography image is critical to the quality of clinical practice. In this sense, dosimetry using optically stimulated luminescent detectors (OSLD) is configured as alternative to traditional methods and allows on-site dose checks received by patients. This study aimed to verify the performance of OSL dosimeters in clinical beams typically used in mammography. For this, aluminum oxide detectors, especially designed to reduce interference on the image quality, were exposed to radiation beam combining targets and filters of a mammography equipment with digital imaging system. In addition were also employed lithium fluoride detectors irradiated under the same conditions, together with a ionization chamber for determination of dose values. A homogeneous acrylic phantom was designed and used for simulating different breast and also determine internal dose values under the irradiation conditions. The results allowed the determination of calibration factors (OSL signal x dose) of the exposed detectors to the radiation beams typically used in clinical practice. The phantom images and the comparison between TL and OSL responses suggest the possibility of routine use of the OSL dosimetry system in mammography. (author)

  19. Development of pulsed stimulation and Photon Timer attachments to the Risø TL/OSL reader

    DEFF Research Database (Denmark)

    Lapp, Torben; Jain, Mayank; Ankjærgaard, Christina

    2009-01-01

    in the OSL/IRSL process, a Photon Timer attachment to the Risø reader has been developed which measures data at 100 ps resolution. Furthermore a post-processing program has been developed to present the data in a compressed 3D form that gives a useful overview of the data before further analysis of relevant...

  20. Developing a SAR TT-OSL protocol for volcanically-heated aeolian quartz from Datong (China)

    DEFF Research Database (Denmark)

    Liu, Jinfeng; Murray, Andrew S.; Jain, Mayank

    2012-01-01

    The thermally-transferred optically stimulated luminescence (TT-OSL) responses of chemically-purified fine-grained quartz from a lava-baked aeolian sediment from Datong (China) are presented. Our main focus is to examine the suitability of the test dose TT-OSL and OSL response to monitor sensitiv......The thermally-transferred optically stimulated luminescence (TT-OSL) responses of chemically-purified fine-grained quartz from a lava-baked aeolian sediment from Datong (China) are presented. Our main focus is to examine the suitability of the test dose TT-OSL and OSL response to monitor...

  1. OSL, TL and IRSL emission spectra of sedimentary quartz and feldspar samples

    International Nuclear Information System (INIS)

    Lomax, Johanna; Mittelstraß, Dirk; Kreutzer, Sebastian; Fuchs, Markus

    2015-01-01

    This contribution presents a variety of different luminescence emission spectra from sedimentary feldspar and quartz samples under various stimulation modes. These are green stimulated quartz (OSL-) spectra, quartz TL spectra, feldspar IRSL and post-IR IRSL spectra. A focus was set at recording OSL and IRSL spectra at elevated stimulation temperatures such as routinely applied in luminescence dating. This was to test whether optical stimulation at elevated temperatures results in a shift of emission peaks. For OSL emissions of quartz, this has so far not been tested. In case of feldspar emissions, post-IR IRSL conditions, hence IRSL emissions at a low temperature, directly followed by high temperature post-IRSL emissions, are explicitly investigated. All spectra were recorded using a new system incorporated into a Lexsyg luminescence reader. Thus, this study, besides presenting new spectral data, also serves as a feasibility study for this new device. It is shown that (a) the new device is capable of automatically measuring different sorts of spectra, also at elevated temperatures, (b) known thermally and optically stimulated peak emissions of quartz and feldspar are confirmed, (c) obtained IRSL and OSL spectra indicate that there is no significant relation between peak emission and stimulation temperature. - Highlights: • We have measured OSL, IRSL and TL emission spectra of sedimentary quartz and feldspar samples. • Spectral analyses were performed at elevated stimulation temperatures. • Emission spectra show very little variation with stimulation temperatures.

  2. OSL signal of IC chips from mobile phones for dose assessment in accidental dosimetry

    International Nuclear Information System (INIS)

    Mrozik, A.; Marczewska, B.; Bilski, P.; Książek, M.

    2017-01-01

    The rapid assessment of the radiation dose is very important for the prediction of biological effects after unintended exposition. The materials for use as dosimeters in accidental dosimetry should be everyday objects which are usually placed near the human body, for example mobile phones. IC (Integrated Circuit) chip is one of several electronic components of mobile phones which give a luminescent signal. The measurements of samples from different mobile phones and smartphones were conducted by optically stimulated luminescence (OSL) and thermoluminescence (TL) methods. The OSL measurement was performed in two ways: with readouts at room temperature and at 100 °C. This work is focused on determination of OSL dose response of IC chips, minimum detectable dose (MDD), OSL signal stability in the time after the exposition, its repeatability and sensitivity to light. Several tests of the assessment of unknown doses were also conducted. The readouts at 100 °C indicate the reducing of the fading of OSL signal in the first hours after irradiation in comparison with room temperature readouts. The obtained results showed relatively good dosimetric properties of IC chips: their high sensitivity to the ionizing radiation, linear dose response up to 10 Gy and a good reproducibility of OSL signal which can allow the dose recovery of doses less than 2 Gy in 14 days after an incident with the accuracy better than 25%. The fading is a drawback of IC chips and the fading factor should be considered when calculating the dose. - Highlights: • IC chips from smartphones demonstrated high potential for accidental dosimetry. • Minimum detectable dose was estimated as a value of 50 mGy. • Samples showed linear dose response for the dose range from 0.05 Gy up to 10 Gy.

  3. Gamma response characterizations of optically stimulated luminescence (OSL) affects personal dosimetry

    Science.gov (United States)

    Monthonwattana, S.; Esor, J.; Rungseesumran, T.; Intang, A.

    2017-06-01

    Optically Stimulated Luminescence (OSL) is the current technique of personal dosimetry changed by Nuclear Technology Service Center instead of Thermoluminescence dosimetry (TLD) because OSL has more advantages, such as repeat reading and elimination of heating process. In this study, OSL was used to test the gamma response characterizations. Detailed OSL investigation on personal dosimetry was carried out in the dose range of 0.2 - 3.0 mSv. The batch homogeneity was 7.66%. R2 value of the linear regression was 0.9997. The difference ratio of angular dependence at ± 60° was 8.7%. Fading of the reading was about 3%.

  4. Constraining the timing of palaeosol development in Iranian arid environments using OSL dating

    DEFF Research Database (Denmark)

    Rashidi, Zakieh; Sohbati, Reza; Karimi, Alireza

    2018-01-01

    are compared to investigate the degree of bleaching of quartz OSL in individual samples at the time of deposition. A comparison between the quartz OSL and K-feldspar IR50 ages shows that 12 out of 15 samples were probably well-bleached prior to deposition. The 17 OSL ages constrain at least four broad phases......The ages of palaeosols in arid environments in Iran are constrained using the optically stimulated luminescence (OSL) signal from quartz. The luminescence properties of quartz OSL and K-feldspar infrared stimulated luminescence (IRSL) at 50 °C (IR50) and post-IR IRSL at 290 °C (pIRIR290) signals...

  5. Influence of pre-measurement thermal treatment on OSL of synthetic quartz measured at room temperature

    International Nuclear Information System (INIS)

    Kale, Y.D.; Gandhi, Y.H.

    2008-01-01

    Much effort has been made to study the influence of pre-measurement thermal treatment and ionizing radiation on quartz specimens owing to its use in a large number of applications. Optically stimulated luminescence (OSL) being a structured and sensitive phenomenon promises to correlate the responsible color center and luminescence emission. OSL studies on quartz with such conditions can reveal many significant results. The aim of the present investigation is to understand the effect of annealing temperature on OSL characteristics of synthetic quartz recorded at room temperature. At identical annealing duration and β-dose, the shape of OSL decay curve remains non-exponential; when specimens annealed at lower temperature (∼400 deg. C). The shape of decay curve changes to exponential in nature along with rise in OSL intensity when the specimen was given higher temperature of annealing (>400 deg. C). The effects of such protocol on pattern of OSL sensitivity as well as area under the OSL decay curve are also presented here. The presence of shallow traps, when OSL decay curve was recorded at room temperature seems to be responsible for the changes in OSL pattern. The influence of shallow traps is attributed to non-exponential decay of OSL recorded at room temperature

  6. Desiccants for retrospective dosimetry using optically stimulated luminescence (OSL)

    International Nuclear Information System (INIS)

    Geber-Bergstrand, Therése; Bernhardsson, Christian; Christiansson, Maria; Mattsson, Sören; Rääf, Christopher L.

    2015-01-01

    Optically stimulated luminescence (OSL) was used to test different kinds of desiccants for their potential use in retrospective dosimetry. Desiccants are used for the purpose of absorbing liquids and can be found in a number of items which may be found in the immediate environment of a person, including hand bags, drug packages, and the vehicles of rescue service teams. Any material exhibiting OSL properties suitable for retrospective dosimetry is a useful addition to the existing dosimetry system available in emergency preparedness. Eleven kinds of desiccants were investigated in order to obtain an overview of the fundamental OSL properties necessary for retrospective dosimetry. Measurements were made using a Risø TL/OSL reader and irradiations were achieved with the 90 Sr/ 90 Y source incorporated in the reader. Several of the desiccants exhibited promising properties as retrospective dosemeters. Some of the materials exhibited a strong as-received signal, i.e. without any laboratory irradiation, but the origin of this signal has not yet been established. The minimum detectable dose ranged from 8 to 450 mGy for ten of the materials and for one material (consisting of natural clay) the minimum detectable dose was 1.8 Gy. - Highlights: • Desiccants can be used as fortuitous dosemeters using OSL. • The minimum detectable dose for processed desiccants range from 8 to 450 mGy. • The minimum detectable dose for natural clay was 1.8 Gy

  7. Detection of sub micro Gray dose levels using OSL phosphor LiMgPO_4:Tb,B

    International Nuclear Information System (INIS)

    Rawat, N.S.; Dhabekar, Bhushan; Muthe, K.P.; Koul, D.K.; Datta, D.

    2017-01-01

    Highlights: • LiMgPO4:Tb,B has been studied and shown to possesses minimum measurable dose (MMD) in sub micro Gray region. • MMD as low as 0.49 µGy in readout time of less than 1 s at stimulation intensity of 32 mW/cm"2 has been achieved. • The OSL measurements for low doses has strengthened and validated this claim. • OSL spectrum shows several emission peaks and the prominent peak around 380 nm. - Abstract: Detection of sub micro Gray doses finds application in personnel and environmental monitoring, and nuclear forensics. Recently developed LiMgPO_4:Tb,B (LMP) is highly sensitive Optically Stimulated Luminescence (OSL) phosphor with excellent dosimetric properties. The OSL emission spectrum of LMP consists of several peaks attributed to characteristic Tb"3"+ emission. The OSL emission peak at 380 nm is favorable for bi-alkali PMT used in RISO reader system. It is demonstrated that significant improvement in dose detection threshold can be realized for LMP by optimization of continuous wave (CW–) OSL parameters like stimulation intensity and readout time. The minimum measurable dose (MMD) as low as 0.49 µGy in readout time of less than 1 s at stimulation intensity of 32 mW/cm"2 has been achieved using this phosphor. The recommendations for choice of parameters for personnel and environmental monitoring are also discussed.

  8. Optically stimulated luminescence (OSL) of dental enamel for retrospective assessment of radiation exposure

    International Nuclear Information System (INIS)

    Yukihara, E.G.; Mittani, J.; McKeever, S.W.S.; Simon, S.L.

    2007-01-01

    This paper briefly reviews the optically stimulated luminescence (OSL) properties of dental enamel and discusses the potential and challenges of OSL for filling the technology gap in biodosimetry required for medical triage following a radiological/nuclear accident or terrorist event. The OSL technique uses light to stimulate a radiation-induced luminescence signal from materials previously exposed to ionizing radiation. This luminescence originates from radiation-induced defects in insulating crystals and is proportional to the absorbed dose of ionizing radiation. In our research conducted to date, we focused on fundamental investigations of the OSL properties of dental enamel using extracted teeth and tabletop OSL readers. The objective was to obtain information to support the development of the necessary instrumentation for retrospective dosimetry using dental enamel in laboratory, or for in situ and non-invasive accident dosimetry using dental enamel in emergency triage. An OSL signal from human dental enamel was detected using blue, green, or IR stimulation. Blue/green stimulation associated with UV emission detection seems to be the most appropriate combination in the sense that there is no signal from un-irradiated samples and the shape of the OSL decay is clear. Improvements in the minimum detection level were achieved by incorporating an ellipsoidal mirror in the OSL system to maximize light collection. Other possibilities to improve the sensitivity and research steps necessary to establish the feasibility of the technique for retrospective assessment of radiation exposure are also discussed

  9. Integrated circuits from mobile phones as possible emergency OSL/TL dosimeters

    International Nuclear Information System (INIS)

    Sholom, S.; McKeever, S.W.S.

    2016-01-01

    In this article, optically stimulated luminescence (OSL) data are presented from integrated circuits (ICs) extracted from mobile phones. The purpose is to evaluate the potential of using OSL from components in personal electronic devices such as smart phones as a means of emergency dosimetry in the event of a large-scale radiological incident. ICs were extracted from five different makes and models of mobile phone. Sample preparation procedures are described, and OSL from the IC samples following irradiation using a 90 Sr/ 90 Y source is presented. Repeatability, sensitivity, dose responses, minimum measurable doses, stability and fading data were examined and are described. A protocol for measuring absorbed dose is presented, and it was concluded that OSL from these components is a viable method for assessing dose in the days following a radiological incident. (authors)

  10. Natural and laboratory OSL growth curve–Verification of the basic assumption of luminescence dating

    International Nuclear Information System (INIS)

    Kijek, N.; Chruścińska, A.

    2016-01-01

    The basic assumption of luminescence dating is the equality between the growth curve of OSL generated by the natural radiation and the OSL growth curve reconstructed in laboratory conditions. The dose rates that generate the OSL in nature and in laboratory experiments differ by about ten orders of magnitude. Recently some discrepancies between the natural and laboratory growth curves have been observed. It is important to establish their reasons in order to introduce appropriate correction into the OSL dating protocol or to find a test that allows to eliminate the samples which should not be used for dating. For this purpose, both growth curves, natural and laboratory, were reconstructed by means of computer simulations of the processes occurring in the sample during its deposition time in environment as well as those which occur in a laboratory during dating procedure. The simulations were carried out for three models including one shallow trap, two OSL traps, one disconnected deep and one luminescence center. The OSL model for quartz can be more complex than the one used in the presented simulations, but in spite of that the results show effects of growth curves discrepancies similar to those observed in experiments. It is clear that the consistency of growth curves is not a general feature of the OSL processes, but rather a result of an advantageous configuration of trap parameters. The deep disconnected traps play the key role and their complete filling before the zeroing of OSL signal is a necessary condition of the growth curves' consistency. - Highlights: • Process of OSL growth curve generation in nature and in laboratory was simulated. • Discrepancies between the natural and the laboratory growth curves are observed. • Deep disconnected traps play the key role in growth curve inequality. • Empty deep traps before zeroing of OSL cause the inequality of growth curves.

  11. Application of pulsed OSL to the separation of the luminescence components from a mixed quartz/feldspar sample

    International Nuclear Information System (INIS)

    Denby, P.M.; Botter-Jensen, L.; Murray, A.S.; Thomsen, K.J.; Moska, P.

    2006-01-01

    It is known that the pulsed optically stimulated luminescence (OSL) characteristics of quartz and feldspars are very different. These differences can be used to preferentially discriminate against the feldspar signal in mixed quartz-bar feldspar mineral assemblages, or in separated quartz contaminated with a feldspar signal. We have developed instrumentation for the study of high-speed pulse stimulated OSL. Our system uses the standard blue/IR LED stimulation unit of a Riso reader (allowing stimulation pulses down to 1-2μs duration) and can thus be applied to the routine analysis of samples. Using this stimulation source, and high-speed photon timing, the OSL yield can be monitored throughout the pulsing cycle and subsequent OSL decay. It is found that the total photon yield per unit stimulation power in pulsed mode is, for quartz, twice and, for feldspar, nearly four times, that in continuous wave mode. Observation of this OSL signal, between stimulation pulses, is seen to be characteristic of the mineral being examined, and has been used to preferentially discriminate against feldspar contamination in a mixed quartz/feldspar sample. Simple implementation of this technique by gating the counting period, so that counts are only accumulated during a windowed period, reduces the feldspar signal to 1.6% of its original value relative to that of the quartz

  12. Emergency EPR and OSL dosimetry with table vitamins and minerals.

    Science.gov (United States)

    Sholom, S; McKeever, S W S

    2016-12-01

    Several table vitamins, minerals and L-lysine amino acid have been preliminarily tested as potential emergency dosemeters using electron paramagnetic resonance (EPR) and optically stimulated luminescence (OSL) techniques. Radiation-induced EPR signals were detected in samples of vitamin B2 and L-lysine while samples of multivitamins of different brands as well as mineral Mg demonstrated prominent OSL signals after exposure to ionizing radiation doses. Basic dosimetric properties of the radiation-sensitive substances were studied, namely dose response, fading of the EPR or OSL signals and values of minimum measurable doses (MMDs). For EPR-sensitive samples, the EPR signal is converted into units of dose using a linear dose response and correcting for fading using the measured fading dependence. For OSL-sensitive materials, a multi-aliquot, enhanced-temperature protocol was developed to avoid the problem of sample sensitization and to minimize the influence of signal fading. The sample dose in this case is also evaluated using the dose response and fading curves. MMDs of the EPR-sensitive samples were below 2 Gy while those of the OSL-sensitive materials were below 500 mGy as long as the samples are analyzed within 1 week after exposure. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Modelling the thermal bleaching of OSL signal in the case of a competition between recombination centres

    International Nuclear Information System (INIS)

    Chruscinska, A.

    2009-01-01

    The thermal bleaching of the optically stimulated luminescence (OSL) has been investigated by computer simulations for a model including three traps and two luminescence centres. The deepest trap is active only during the OSL process. Two other traps are active only during the thermal bleaching. The thermal bleaching effects on the OSL intensity as well as on the OSL curve shape are presented for the wide range of trap and luminescence centre parameters and for the different settings of optical detection window. The conventional OSL curve analysis consisting in decomposition of the OSL curve into first order components is applied to the simulation results and the optical cross section spectra obtained as a result of this analysis are compared with the model assumptions. The simulations show that OSL signal can decrease to undetectable level even when the traps related to this signal are not emptied during thermal bleaching. The residual level of the OSL signal after bleaching process, however, depends strongly on centre parameters and concentrations. The modifications of optical detection spectral window lead to significant changes of bleaching effects. The thermal bleaching influences also the optical cross section spectra obtained as a result of the OSL curve decomposition.

  14. Assessing the completeness of optical resetting of quartz OSL in the natural environment

    International Nuclear Information System (INIS)

    Singarayer, J.S.; Bailey, R.M.; Ward, S.; Stokes, S.

    2005-01-01

    Resetting of previously accumulated optically stimulated luminescence (OSL) signals during transport of sediment is a fundamental requirement for reliable optical dating. The completeness of optical resetting of 46 modern-age quartz samples from a variety of depositional environments was examined. All equivalent dose (D e ) estimates were e from easy-to-bleach through to hard-to-bleach components. For all modern fluvial samples with non-zero D e values, SAR D e (t) analysis and component-resolved linearly modulated OSL (LM OSL) D e estimates showed this to be the case, implying incomplete resetting of previously accumulated charge. LM OSL measurements were also made to investigate the extent of bleaching of the slow components in the natural environment. In aeolian sediments examined, the natural LM OSL was effectively zero (i.e. all components were fully reset). The slow components of modern fluvial samples displayed measurable residual signals up to 15Gy

  15. A fiber-dosimetry method based on OSL from Al2O3:C for radiotherapy applications

    International Nuclear Information System (INIS)

    Gaza, R.; McKeever, S.W.S.; Akselrod, M.S.; Akselrod, A.; Underwood, T.; Yoder, C.; Andersen, C.E.; Aznar, M.C.; Marckmann, C.J.; Boetter-Jensen, L.

    2004-01-01

    We describe a high-sensitivity, fiber-optic dosimetry system based on optically stimulated luminescence (OSL) and radioluminescence from Al 2 O 3 :C single-crystal fibers (detectors). The detectors are coupled to a fiber optic delivery system and OSL from the detector is stimulated via the optical fiber cable using light from a Nd:YAG laser. The OSL is guided back along the same fiber and is detected by a photomultiplier tube. The Al 2 O 3 :C detectors are small and demonstrate high sensitivity with a large signal-to-noise ratio. We describe two modes of operation of the system and discuss algorithms that provide accurate estimation of dose rate and integrated dose in near real time. The system is free from magnetic and electrical interference, and is designed for use in several forms of radiotherapy, including in vitro brachytherapy source calibration, and in vivo dosimetry during patient treatment

  16. INTEGRATED CIRCUITS FROM MOBILE PHONES AS POSSIBLE EMERGENCY OSL/TL DOSIMETERS.

    Science.gov (United States)

    Sholom, S; McKeever, S W S

    2016-09-01

    In this article, optically stimulated luminescence (OSL) data are presented from integrated circuits (ICs) extracted from mobile phones. The purpose is to evaluate the potential of using OSL from components in personal electronic devices such as smart phones as a means of emergency dosimetry in the event of a large-scale radiological incident. ICs were extracted from five different makes and models of mobile phone. Sample preparation procedures are described, and OSL from the IC samples following irradiation using a (90)Sr/(90)Y source is presented. Repeatability, sensitivity, dose responses, minimum measureable doses, stability and fading data were examined and are described. A protocol for measuring absorbed dose is presented, and it was concluded that OSL from these components is a viable method for assessing dose in the days following a radiological incident. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Detection of sub micro Gray dose levels using OSL phosphor LiMgPO{sub 4}:Tb,B

    Energy Technology Data Exchange (ETDEWEB)

    Rawat, N.S., E-mail: naru@barc.gov.in [Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Trombay, Mumbai (India); Dhabekar, Bhushan [Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Trombay, Mumbai (India); Muthe, K.P. [Technical Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai (India); Koul, D.K.; Datta, D. [Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Trombay, Mumbai (India)

    2017-04-15

    Highlights: • LiMgPO4:Tb,B has been studied and shown to possesses minimum measurable dose (MMD) in sub micro Gray region. • MMD as low as 0.49 µGy in readout time of less than 1 s at stimulation intensity of 32 mW/cm{sup 2} has been achieved. • The OSL measurements for low doses has strengthened and validated this claim. • OSL spectrum shows several emission peaks and the prominent peak around 380 nm. - Abstract: Detection of sub micro Gray doses finds application in personnel and environmental monitoring, and nuclear forensics. Recently developed LiMgPO{sub 4}:Tb,B (LMP) is highly sensitive Optically Stimulated Luminescence (OSL) phosphor with excellent dosimetric properties. The OSL emission spectrum of LMP consists of several peaks attributed to characteristic Tb{sup 3+} emission. The OSL emission peak at 380 nm is favorable for bi-alkali PMT used in RISO reader system. It is demonstrated that significant improvement in dose detection threshold can be realized for LMP by optimization of continuous wave (CW–) OSL parameters like stimulation intensity and readout time. The minimum measurable dose (MMD) as low as 0.49 µGy in readout time of less than 1 s at stimulation intensity of 32 mW/cm{sup 2} has been achieved using this phosphor. The recommendations for choice of parameters for personnel and environmental monitoring are also discussed.

  18. The preliminary application of OSL in comparison with TL for authentication of ancient Chinese bricks

    International Nuclear Information System (INIS)

    Leung, P.L.; Tang Qiang; Li, Mike; Zhang Chunxiang

    2005-01-01

    The single-aliquot regenerative-dose (SAR) protocol with optically stimulated luminenscence (OSL) was applied to measure the equivalent dose (ED) of ancient Chinese bricks ranging in age from 180 to 1600 years. In the protocol, sensitivity changes can be corrected by using OSL response to a fixed test dose during measurement. For comparative study between OSL and TL, thermoluminescence (TL) measurement procedures were also applied to determine the paleodose of the bricks. Both results of OSL and TL are in agreement with the known ages of the bricks, and the paleodose ratios(ED OSL / ED TL ) are between 0.96 and 1.21, mean value 1.08+/-0.02. The annual doses of the bricks, estimated by the paleodoses and the known ages, range from 5.07 to 6.79mGy/a, comparable with the measured annual dose values of the bricks. Therefore, it is concluded that the SAR protocol is a rapid and effective OSL technique to authenticate Chinese bricks

  19. A comparative study between OSL and TL techniques for the dating of ancient chinese bricks

    International Nuclear Information System (INIS)

    Leung, P.L.; Li, M.; Tang Qiang; Zhang Chunxiang

    2004-01-01

    The single-aliquot regenerative-dose (SAR) protocol to the optically stimulated luminescence (OSL) was applied to measure the paleodose of ancient Chinese bricks with an age range from 180 to 1600 years. In the protocol, sensitivity changes can be corrected by using OSL response to a fixed test dose during measurement. For comparative study between OSL and TL, thermoluminescence (TL) measurement procedures were also applied to determine the paleodose of the bricks. Both results of OSL and TL are in good agreement with, and the paleodose ratios (De OSL /De TL ) are between 0.96 and 1.21, with a mean value of 1.08 ± 0.07. The annual dose of the bricks, estimated by the paleodoses and the known ages, ranges from 5.07 to 6.85 mGy/a, comparable with the measured annual dose values. Therefore, it is concluded that the SAR protocol is a rapid and effective OSL technique to authenticate Chinese bricks. (authors)

  20. OSL-thermochronometry using bedrock quartz: a note of caution

    DEFF Research Database (Denmark)

    Guralnik, B.; Ankjærgaard, Christina; Jain, Mayank

    2015-01-01

    Optically stimulated luminescence (OSL) thermochronometry is an emerging application, whose capability to record sub-Million-year thermal histories is of increasing interest to a growing number of subdisciplines of Quaternary research. However, several recent studies have encountered difficulties......, and may hamper successful OSL dating. Furthermore, even when the desirable signal is present, its concentration might be indistinguishable from its environmental steady-state prediction, thus preventing its conversion to a cooling or heating history. We explore the saturation properties and the thermal...

  1. A comparison of single and multiple aliquot TT-OSL data sets for sand-sized quartz from the Arabian Peninsula

    International Nuclear Information System (INIS)

    Rosenberg, T.M.; Preusser, F.; Wintle, A.G.

    2011-01-01

    The quartz OSL signal from dune sands from Saudi Arabia and Oman start to saturate at doses of about 100 Gy. In order to try to date dune sands with greater expected doses, a previously published, single-aliquot, regenerative-dose protocol (SAR) for thermally-transferred optically stimulated luminescence (TT-OSL) was tested. Dose recovery tests, recycling and recuperation ratios showed robust functioning and dose response curves demonstrated the potential to extend the dose range to beyond 600 Gy. Multiple aliquot additive dose (MAAD) TT-OSL protocols were used to test for sensitivity changes in the SAR TT-OSL protocol up to doses of 1200 Gy. A strong dose dependent deviation of the SAR TT-OSL relative to the MAAD TT-OSL dose response is observed. Comparison of the TT-OSL and OSL sensitivity data obtained from the MAAD and SAR data sets shows a lack of proportionality between TT-OSL and OSL for the SAR data which will result in a problem when SAR dose response curves are constructed using many regeneration points with doses above 300 Gy.

  2. An investigation of coseismic OSL / TL time zeroing of quartz gouge based on low- to high-velocity friction experiments

    Science.gov (United States)

    Akasegawa, K.; Oohashi, K.; Hasebe, N.; Miura, K.

    2016-12-01

    To determine an age of coseismic event of an active fault, we generally examine crosscutting relationship between faults and overlying strata by trenching. However, we could not apply this method in case there are no overlying young strata in the vicinity of the fault zones. The alternative is a dating of fault zone materials whose age experienced resetting with seismic fault slip (for example, the ESR method;. Ikeya et al,1982; the OSL and TL methods). The idea behinds to the OSL (optically stimulated luminescence) and TL (thermoluminescence) dating methods for a determination of paleo-earthquake event is the accumulated natural radiation damage becomes to zero (time zeroing) by the frictional heating and grinding. However, physical and geological conditions required to induce time zeroing is not well understood because there is only few experimental investigations under the limited conditions (Hiraga et al,2004;. Kim et al, 2014) . In this study, we conduct low- to high-velocity friction experiments using quartz gouge under various experimental conditions (e.g., normal stress, displacement, moisture content) to establish an empirical relationship and physical and geological conditions of coseismic OSL time zeroing. In this experiment, we carry out the friction experiments using quartz in Tsushigawa granite taken from the east wall of the Nojima fault Ogura trench site, which was excavated in 2015. Samples were taken from the most distant position from the fault in the trench site. The samples were clashed using a mortar and sieved to a grain size of treatment. The residual is user for the friction experiments after having known radiation dose using an artificial gamma-ray source. In this presentation, we show results of the friction experiments and dating of the quartz gouge and discuss physical and geological conditions of OSL time zeroing. References Okumura, T., and Shitaoka, Y., 2011. Engineering Geology of Japan, No. 1, 5-17. Hiraga, S., Yoshimoto, A., and

  3. Luminescence characteristics of quartz from the Southern Kenyan Rift Valley: Dose estimation using LM-OSL SAR

    International Nuclear Information System (INIS)

    Choi, J.H.; Duller, G.A.T.; Wintle, A.G.; Cheong, C.-S.

    2006-01-01

    Linearly modulated (LM) optically stimulated luminescence (OSL) measurements have revealed that some sedimentary quartz samples from the Kenyan Rift Valley do not have a fast OSL component, but contain a medium component and several slow components. It was impossible to recover a known dose for these samples using the conventional single-aliquot regenerative-dose (SAR) procedure. The dose-response curves and continuous wave (CW) OSL decay curves for these samples showed several undesirable properties for dating. We have compared various luminescence characteristics of these samples with other quartz samples from elsewhere in the world for which the SAR procedure has been shown to be appropriate; the latter were dominated by a fast OSL component. The characteristics include photoionisation cross-sections for each component and the relative proportions of the different components in the initial and total OSL signals. It was found that those samples that had greater than 90% of the initial 0.8 s of their OSL signal from the fast component were suitable for dating using the conventional SAR protocol. A novel method of displaying the relative contributions of the different OSL components in a ternary diagram is proposed. The thermal stability of each component was investigated using pulse-annealing experiments. We then examined the possibility of applying an LM-OSL SAR protocol to samples that have a substantial medium component

  4. Thermally assisted OSL from deep traps in Al2O3:C

    International Nuclear Information System (INIS)

    Polymeris, G.S.; Raptis, S.; Afouxenidis, D.; Tsirliganis, N.C.; Kitis, G.

    2010-01-01

    The present work suggests an alternative experimental method in order to not only measure the signal of the deep traps in Al 2 O 3 :C without heating the sample to temperatures greater than 500 o C, but also use this signal for high dose level dosimetry purposes as well. This method consists of photo transfer OSL measurements performed at elevated temperatures using the blue LEDs (470 nm, FWHM 20 nm) housed at commercial Riso TL/OSL systems, after the sample was previously heated up to 500 o C in order to empty its main TL dosimetric trap. The influence of this procedure on specific features such as glow curve shape and sensitivity of the main TL glow peak was also studied.

  5. OSL response bleaching of BeO samples, using fluorescent light and blue LEDs

    International Nuclear Information System (INIS)

    Groppo, Daniela Piai; Caldas, Linda V.E.

    2015-01-01

    The optically stimulated luminescence (OSL) is widely used as a dosimetric technique for many applications. In this work, the OSL response bleaching of BeO samples was studied. The samples were irradiated using a beta radiation source ( 90 Sr+ 90 Y); the bleaching treatments (fluorescent light and blue LEDs) were performed, and the results were compared. Various optical treatment time intervals were tested until reaching the complete bleaching of the OSL response. The best combination of the time interval and bleaching type was analyzed. (author)

  6. OSL response bleaching of BeO samples, using fluorescent light and blue LEDs

    International Nuclear Information System (INIS)

    Groppo, D P; Caldas, L V E

    2016-01-01

    The optically stimulated luminescence (OSL) is widely used as a dosimetric technique for many applications. In this work, the OSL response bleaching of BeO samples was studied. The samples were irradiated using a beta radiation source ("9"0Sr+"9"0Y); the bleaching treatments (fluorescent light and blue LEDs) were performed, and the results were compared. Various optical treatment time intervals were tested until reaching the complete bleaching of the OSL response. The best combination of the time interval and bleaching type was analyzed. (paper)

  7. A compact design for monochromatic OSL measurements in the wavelength range 380-1020 NM

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Poolton, N.R.J.; Willumsen, F.

    1994-01-01

    automated Riso TL/OSL dating apparatus, thus allowing for either routine scanning or more detailed thermo-optical investigations. The high throughput efficiency of the unit means that the existing 75 W tungsten-halogen lamp can be directly used for such measurements on both quartz and feldspar samples......The development and performance of a compact module is described that allows for the monochromatic illumination of samples in the wavelength range 380-1020 nm, enabling the measurement of energy-resolved optically stimulated luminescence. The unit is designed to couple directly to the existing....... The design allows for rapid spectral scanning with a choice of resolution of anywhere between 10 and 80 nm: stray light levels are less than 0.01%. The unit can equally be used for recording wavelength-resolved emission spectra, whether photo-excited or thermally stimulated; the capabilities of the system...

  8. Correlation of basic TL, OSL and IRSL properties of ten K-feldspar samples of various origins

    Energy Technology Data Exchange (ETDEWEB)

    Sfampa, I.K. [Aristotle University of Thessaloniki, Nuclear Physics Laboratory, 54124 Thessaloniki (Greece); Polymeris, G.S. [Institute of Nuclear Sciences, Ankara University, 06100 Besevler, Ankara (Turkey); Pagonis, V. [McDaniel College, Physics Department, Westminster, MD 21157 (United States); Theodosoglou, E. [Department of Mineralogy-Petrology-Economic Geology, School of Geology, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Tsirliganis, N.C. [Laboratory of Radiation Applications and Archaeological Dating, Department of Archaeometry and Physicochemical Measurements, ‘Athena’ R.& I.C., Kimmeria University Campus, GR67100 Xanthi (Greece); Kitis, G., E-mail: gkitis@auth.gr [Aristotle University of Thessaloniki, Nuclear Physics Laboratory, 54124 Thessaloniki (Greece)

    2015-09-15

    Highlights: • OSL and IRSL bleaching behavior of ten K-feldspar samples is presented. • OSL and IRSL decay curves were component resolved using tunneling model. • The growth of integrated OSL and IRSL signals versus time was described by new expression based on tunneling model. • Correlation between TL, OSL and IRSL signals and of all properties with K-feldspar structure was discussed. - Abstract: Feldspars stand among the most widely used minerals in dosimetric methods of dating using thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Having very good dosimetric properties, they can in principle contribute to the dating of every site of archaeological and geological interest. The present work studies basic properties of ten naturally occurring K-feldspar samples belonging to three feldspar species, namely sanidine, orthoclase and microcline. The basic properties studied are (a) the influence of blue light and infrared stimulation on the thermoluminescence glow-curves, (b) the growth of OSL, IRSL, residual TL and TL-loss as a function of OSL and IRSL bleaching time and (c) the correlation between the OSL and IRSL signals and the energy levels responsible for the TL glow-curve. All experimental data were fitted using analytical expressions derived from a recently developed tunneling recombination model. The results show that the analytical expressions provide excellent fits to all experimental results, thus verifying the tunneling recombination mechanism in these materials and providing valuable information about the concentrations of luminescence centers.

  9. Thermal activation of OSL as a geothermometer for quartz grain heating during fault movements

    CERN Document Server

    Rink, W J; Rees-Jones, J; Schwarcz, H P

    1999-01-01

    In discussions of ESR dating of fault movements, there has been much debate whether zeroing of ESR signals is a mechanical shearing effect or caused by frictional heating. The OSL (optically stimulated luminescence) sensitivity of quartz is known to increase after heating. This thermal activation of dose response of the OSL in quartz should be useful as a geothermometer to test whether quartz particles in fault gouge had been heated. We tested the OSL sensitivities of quartz from fault gouge, and from a control (quartz grains from sandstone) and were able to show heat-induced enhancement of OSL sensitivity to a test dose. We observed that relative enhancement of OSL dose response (ratio of heated to unheated single aliquots) is significantly less for the finest grains (45-75 and 100-150 mu m) compared with coarser grains (150-250 mu m). These data are consistent with a model of zeroing of the quartz grains during faulting, by frictional heating localized to the grain boundaries, which would be expected to aff...

  10. Pure thermal sensitisation and pre-dose effect of OSL in both unfired and annealed quartz samples

    Energy Technology Data Exchange (ETDEWEB)

    Oniya, Ebenezer O., E-mail: ebenezer.oniya@aaua.edu.ng [Physics and Electronics Department, Adekunle Ajasin University, 342111 Akungba Akoko (Nigeria); Polymeris, George S. [Institute of Nuclear Sciences, Ankara University, Beşevler 06100, Ankara (Turkey); Jibiri, Nnamdi N. [Department of Physics, University of Ibadan, Ibadan (Nigeria); Tsirliganis, Nestor C. [Department of Archaeometry and Physicochemical Measurements, R.C. ‘Athena’, P.O. Box 159, Kimmeria University Campus, 67100 Xanthi (Greece); Babalola, Israel A. [Department of Physics, University of Ibadan, Ibadan (Nigeria); Kitis, George [Nuclear Physics Laboratory, Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece)

    2017-06-01

    The sensitisation of quartz has attracted much attention since its thorough understanding is important in luminescence studies and dating applications. The present investigation examines the influence of pure thermal activation and predose treatments on the sensitisation of different components of linearly modulated optically stimulated luminescence (LM-OSL) measured at room temperature (RT) thereby eliminating undesired thermal quenching effects. Annealed and unfired quartz samples from Nigeria were used. The OSL measurements were carried out using an automated RISØTL/OSL reader (model-TL/OSL–DA–15). A new approach was adopted to match each of the resolved components of the RT-LM-OSL to respective thermoluminescence (TL) peaks that share the same electron trap and recombination centers. Pure thermal activation and pre-dose treatments respectively affect the sensitisation of all the components of the RT-LM-OSL in a similar manner as the one reported for the 110 °C TL peak but without thermal quenching contributions. Component C4 in annealed samples that was identified to share the same electron trap and recombination centers with the 110 °C TL peak was also proved appropriate for RT-LM-OSL, instead of the initial part of the continuous wave (CW) OSL signal, thus the methods can serve as complementary dating methods.

  11. Pure thermal sensitisation and pre-dose effect of OSL in both unfired and annealed quartz samples

    International Nuclear Information System (INIS)

    Oniya, Ebenezer O.; Polymeris, George S.; Jibiri, Nnamdi N.; Tsirliganis, Nestor C.; Babalola, Israel A.; Kitis, George

    2017-01-01

    The sensitisation of quartz has attracted much attention since its thorough understanding is important in luminescence studies and dating applications. The present investigation examines the influence of pure thermal activation and predose treatments on the sensitisation of different components of linearly modulated optically stimulated luminescence (LM-OSL) measured at room temperature (RT) thereby eliminating undesired thermal quenching effects. Annealed and unfired quartz samples from Nigeria were used. The OSL measurements were carried out using an automated RISØTL/OSL reader (model-TL/OSL–DA–15). A new approach was adopted to match each of the resolved components of the RT-LM-OSL to respective thermoluminescence (TL) peaks that share the same electron trap and recombination centers. Pure thermal activation and pre-dose treatments respectively affect the sensitisation of all the components of the RT-LM-OSL in a similar manner as the one reported for the 110 °C TL peak but without thermal quenching contributions. Component C4 in annealed samples that was identified to share the same electron trap and recombination centers with the 110 °C TL peak was also proved appropriate for RT-LM-OSL, instead of the initial part of the continuous wave (CW) OSL signal, thus the methods can serve as complementary dating methods.

  12. Relative response of TL and component-resolved OSL to alpha and beta radiations in annealed sedimentary quartz

    International Nuclear Information System (INIS)

    Polymeris, George S.; Afouxenidis, Dimitrios; Raptis, Spyridoula; Liritzis, Ioannis; Tsirliganis, Nestor C.; Kitis, George

    2011-01-01

    Knowledge of the relative luminescence response to alpha and beta radiation is very important in TL and OSL dating. In the present study the relative alpha to beta response is studied in a sedimentary quartz sample, previously fired at 900 deg. C for 1 h, in the dose region between 1 and 128 Gy, for both thermoluminescence (TL) and linearly modulated optically stimulated luminescence (LM - OSL). The LM - OSL measurements were performed at room temperature and at 125 deg. C. All OSL signals were deconvolved into their individual components. Comparison of OSL curves after alpha and beta irradiation strongly supports that quartz OSL components follow first order kinetics in both cases. In the case of TL, the relative alpha to beta response is found to be very different for each TL glow-peak, but it does not depend strongly on irradiation dose. In the case of LM - OSL measurements, it is found that the relative behaviour of the alpha to beta response is different for three distinct regions, namely the fast OSL component, the region of medium OSL component originating from the TL glow-peak at 110 deg. C when stimulation takes place at room temperature and finally the region of slow OSL component. Following stimulation at ambient temperature, the relative alpha to beta response of all components was not observed to depend significantly on dose, with the value of ratio being 0.03 and a tendency to decrease with increasing dose. However, in the case of measurements performed at 125 deg. C, the relative response of the fast components is much enhanced, and for the remaining components it increases with increasing dose. Special care must be taken to examine the relative alpha to beta response of the fast component at 125 deg. C which contrasts the relative response of the TL peak at ca. 325 deg. C. The implications for the dating of annealed quartz are also briefly discussed. - Highlights: → Relative alpha to beta response for TL and LM-OSL is studied in annealed

  13. Study of optically stimulated luminescence (OSL) for radiation detection. Application to an optical fibre γ-radiation sensor

    International Nuclear Information System (INIS)

    Roy, O.

    1998-01-01

    This work shows up the usefulness of the Optically Stimulated Luminescence (OSL) to resolve radioprotection problems. We study the use of OSL as a gamma dosimetric technique with respect to the ALARA's concept (As Low As Reasonably Achievable). A new approach based on optical fibers and luminescent materials showing OSL properties (closely related to Thermoluminescence phenomena) is presented in order to improve the remote real time dosimetry monitoring. Like thermoluminescent materials (TLD), OSL materials can trap charges under an irradiation (UV, X, γ,...). Instead of heating, the charges trapped are released by light stimulation and produce a visible luminescence which amount is proportional to trap the 'data stored' left by irradiation, enabling the dose measurement. The OSL phenomenon offers the same advantages as TLD plus the interesting possibility of a remote optical stimulation. The end-user objective deals with the development of a γ-radiation Optical FIber Sensor (OFS) for dose measurement which can offer new functionalities based on OSL materials coupled with an optical fiber. Rare earth doped Alkaline Earth Sulphides (AES), BAFX:EU 2+ (X = Cl, Br, I) and halogen alkaline have been studied (crystalline form, synthesis techniques, influence of dopants and color centers). Their characteristics are presented and extensively discussed. A specific experimental set-up to characterise various OSL phosphors has been developed. It allows the study of sensitivity, linearity, time decay behaviour of OSL signal and zeroing time. A joint study of OSL and TL has shown the technical limitations as well as the thermal fading and the origin of the long zeroing time. An Optical Fiber Sensor (OFS) based on OSL and using MgS:Sm has been developed for practical applications on nuclear fields. Its specifications are presented and discussed, moreover improvements are proposed. (author)

  14. Firing temperature of pottery using TL and OSL techniques

    International Nuclear Information System (INIS)

    Polymeris, G.S.; Sakalis, A.; Papadopoulou, D.; Dallas, G.; Kitis, G.; Tsirliganis, N.C.

    2007-01-01

    Several methods of thermal analysis are used to determine in the laboratory the firing temperature of ancient ceramic sherds. These methods are based primarily on changes of physical characteristics occurring when clay minerals are heated. The luminescence properties of quartz grains in a ceramic matrix also undergo certain changes during firing. The possibility of measuring the sensitivity change (sensitization) of quartz in order to determine the firing temperature of archeological ceramic artifacts was investigated. The sensitivity change was studied for both the thermoluminescence (TL) and the optically stimulated luminescence (OSL) signal for a ceramic sample of known firing temperature. Various segments of the sample were annealed to a different temperature. Subsequently, the initial sensitivity, as well as the thermal and the pre-dose sensitization were measured for both TL and OSL at room temperature as a function of the annealing temperature. The obtained TL glow curves showed different shapes for annealing temperatures above the firing temperature. Thermal and pre-dose sensitizations also exhibited a similar, although less prominent, rise. The OSL signal was analyzed by integrating the raw signal over the initial second of stimulation. The initial sensitivity showed an abrupt change for annealing temperatures around the firing temperature. An alternative approach used for the analysis of the OSL signal involved a full-component resolved sensitization study. The same abrupt change for the initial sensitivity of both the first and second components was observed, as well as, a clear but not very prominent thermal sensitization trend for annealing temperatures above the firing temperature

  15. Study of optically stimulated luminescence (OSL) for radiation detection. Application to an optical fibre {gamma}-radiation sensor; Etude de la luminescence stimulee optiquement (OSL) pour la detection de rayonnements: application a un capteur a fibre optique de rayonnement {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Roy, O. [CEA Saclay, 91 - Gif-sur-Yvette (France). Dept. d`Electronique et d`Instrumentation Nucleaire]|[Paris-7 Univ., 75 (France)

    1998-12-31

    This work shows up the usefulness of the Optically Stimulated Luminescence (OSL) to resolve radioprotection problems. We study the use of OSL as a gamma dosimetric technique with respect to the ALARA`s concept (As Low As Reasonably Achievable). A new approach based on optical fibers and luminescent materials showing OSL properties (closely related to Thermoluminescence phenomena) is presented in order to improve the remote real time dosimetry monitoring. Like thermoluminescent materials (TLD), OSL materials can trap charges under an irradiation (UV, X, {gamma},...). Instead of heating, the charges trapped are released by light stimulation and produce a visible luminescence which amount is proportional to trap the `data stored` left by irradiation, enabling the dose measurement. The OSL phenomenon offers the same advantages as TLD plus the interesting possibility of a remote optical stimulation. The end-user objective deals with the development of a {gamma}-radiation Optical FIber Sensor (OFS) for dose measurement which can offer new functionalities based on OSL materials coupled with an optical fiber. Rare earth doped Alkaline Earth Sulphides (AES), BAFX:EU{sup 2+} (X = Cl, Br, I) and halogen alkaline have been studied (crystalline form, synthesis techniques, influence of dopants and color centers). Their characteristics are presented and extensively discussed. A specific experimental set-up to characterise various OSL phosphors has been developed. It allows the study of sensitivity, linearity, time decay behaviour of OSL signal and zeroing time. A joint study of OSL and TL has shown the technical limitations as well as the thermal fading and the origin of the long zeroing time. An Optical Fiber Sensor (OFS) based on OSL and using MgS:Sm has been developed for practical applications on nuclear fields. Its specifications are presented and discussed, moreover improvements are proposed. (author) 320 refs.

  16. OSL surface exposure dating of a lithic quarry in Tibet: Laboratory validation and application

    DEFF Research Database (Denmark)

    Gliganic, L.A.; Meyer, M.C.; Sohbati, R.

    2018-01-01

    developed OSL Surface exposure dating technique (OSL-Surf) to date flake scars at lithic quarry sites. We performed the first quantitative validation of the model describing the OSL-Surf dating technique using a controlled laboratory experiment. Our results show that longer laboratory bleaching durations......-depth profile that could be used to calibrate the model to estimate the exposure duration of a flake scar associated with human exploitation of the area. Finally, we observe that the μ parameter of the OSL-Surf model varies considerably between the laboratory-bleached and two naturally daylight-bleached...... datasets, despite having identical lithologies. We thus infer that, in addition to lithological controls, the μ parameter is primarily sensitive to the daylight irradiation geometry and only weakly dependent on spectrum of the incident light; this interpretation implies a narrow effective bleaching...

  17. SU-E-T-592: OSL Response of Al2O3:C Detectors Exposed to Therapeutic Proton Beams

    Energy Technology Data Exchange (ETDEWEB)

    Granville, DA [Carleton Laboratory for Radiotherapy Physics, Carleton University, Ottawa, ON (Canada); Flint, DB; Sawakuchi, GO [The University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: To characterize the response of Al{sub 2}O{sub 3}:C optically stimulated luminescence (OSL) detectors (OSLDs) exposed to therapeutic proton beams of differing beam quality. Methods: We prepared Al{sub 2}O{sub 3}:C OSLDs from the same material as commercially available nanoDot dosimeters (Landauer, Inc). We irradiated the OSLDs in modulated proton beams of varying quality, as defined by the residual range. An absorbed dose to water of 0.2 Gy was delivered to all OSLDs with the residual range values varying from 0.5 to 23.5 cm (average LET in water from ∼0.5 to 2.5 keV/µm). To investigate the beam quality dependence of different emission bands within the OSL spectrum, we performed OSLD readouts using both continuous-wave stimulation (CW-OSL) and pulsed stimulation (P-OSL) with two sets of optical filters (Hoya U-340 and Kopp 5113). For all readout modes, the relative absorbed dose sensitivity (S{sub rel}) for each beam quality was calculated using OSLDs irradiated in a 6 MV photon beam as a reference. Results: We found that the relative absorbed dose sensitivity was highly dependent on both readout mode and integration time of the OSL signal. For CW-OSL signals containing only the blue emission band, S{sub rel} was between 0.85 and 0.94 for 1 s readouts and between 0.82 and 0.93 for 10 s readouts. Similarly, for P-OSL readouts containing only the blue emission band S{sub rel} ranged from 0.86 to 0.91, and 0.82 to 0.93 for 1 s and 10 s readouts, respectively. For OSLD signals containing only the UV emission band, S{sub rel} ranged from 1.00 to 1.46, and 0.97 to 1.30 for P-OSL readouts of 1 s and 10 s, respectively. Conclusion: For measurements of absorbed dose using Al{sub 2}O{sub 3}:C OSLDs in therapeutic proton beams, dependence on beam quality was smallest for readout protocols that selected the blue emission band with small integration times. DA Granville received financial support from the Natural Sciences and Engineering

  18. TL and OSL studies of carbon doped magnesium aluminate (MgAl2O4:C)

    Science.gov (United States)

    Raj, Sanu S.; Mishra, D. R.; Soni, Anuj; Grover, V.; Polymeris, G. S.; Muthe, K. P.; Jha, S. K.; Tyagi, A. K.

    2016-10-01

    The MgAl2O4:C has been synthesized by using two different methods by electron gun and vacuum assisted melting of MgAl2O4 in presence of graphite. The MgAl2O4:C phosphor thus developed by these two different methods have similar types of the TL/OSL defects with multiple overlapping TL glow peaks from 100 °C to 400 °C. The Computerized Curve De-convolution Analysis (CCDA) has been used to measure TL parameters such as thermal trap depth, frequency factor and order of kinetic associated with charge transfer process in TL phenomenon. The investigated TL/OSL results show that these two methods of incorporating carbon in MgAl2O4 have generated closely resemble the defects of similar types in MgAl2O4:C lattice. However, the MgAl2O4:C synthesized by electron gun shows relatively larger concentration of the TL/OSL defects as compared to MgAl2O4:C synthesized using vacuum assisted melting method. The photo-ionization cross-section (PIC) associated with fastest OSL component of MgAl2O4: C is found to be ∼ 0.5 times than that of fastest OSL component of commercially available dosimetric grade α-Al2O3:C. The MgAl2O4:C thus developed shows good dynamic OSL dose linearity from few mGy to 1 Gy. This work reveals that MgAl2O4:C could be developed as potential tissue equivalent OSL / TL material.

  19. TL and OSL studies on undoped diamond films grown by hot filament chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Soni, Anuj, E-mail: anujsoni.phy@gmail.com [Radiological Physics and Advisory Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Choudhary, R.K. [Materials Processing Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Polymeris, G.S. [Ankara University, Institute of Nuclear Sciences (Turkey); Mishra, D.R. [Radiological Physics and Advisory Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Mishra, P. [Materials Processing Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Kulkarni, M.S. [Radiation Safety Systems Division, Bhabha Atomic Research Center, Mumbai 400 085 (India)

    2016-09-15

    In this work, approximately 0.5 µm thick diamond films were grown on a silicon substrate by hot filament chemical vapour deposition (HFCVD) method in a gas mixture of hydrogen and methane. The batch to batch reproducibility of the sample using this technique was found to be very good. The obtained film was characterized by micro laser Raman spectroscopy (MLRS), grazing incidence X-ray diffractometry (GIXRD), scanning electron microscopy (SEM) and atomic force miscroscopy (AFM) techniques. MLRS and GIXRD results confirmed the formation of diamond whereas SEM and AFM analyses indicated uniform morphology of the film with an average grain size of 200 nm. The deposited film was studied for ionizing radiation dosimetry applications using the thermoluminescence (TL) and optically stimulated luminescence (OSL) techniques after irradiating the film by a calibrated 5 mCi, {sup 90}Sr/{sup 90}Y beta source. In the TL measurement, for a heating rate of 4 K/s, broad glow curve was obtained which was deconvoluted into seven TL peaks. The integrated TL counts were found to vary linearly with increasing the radiation dose up to 10 kGy. The characteristic TL output seen in the temperature range 200–300 °C, may be considered good for thermal stability of the film and it could also avoid TL fading during storage and non-interference of any black body radiation during the measurement. However, in comparison to TL output, the OSL response for 470 nm LED stimulation was found to be lesser. The CW–OSL decay curve has shown two components contributing to the OSL signal, having photoionization cross-section 1.5×10{sup −18} and 5.2×10{sup −19} cm{sup 2} respectively. The studies have revealed the possibility of using diamond film for high dose radiation dosimetry with TL/OSL method.

  20. LM-OSL signals from some insulators: an analysis of the dependency of the detrapping probability on stimulation light intensity

    DEFF Research Database (Denmark)

    Bulur, E.; Bøtter-Jensen, L.; Murray, A.S.

    2001-01-01

    Optically stimulated luminescence (OSL) signals from various insulators including quartz, Al2O3 : C, BeO and NaCl have been studied using the linear modulation OSL (LM-OSL) technique. LM-OSL is based on the linear increase of the stimulation light power from zero to a maximum during the measurement...... is not always correct. The initial decay rates of the blue (similar to 470 nm) light stimulated constant power OSL decay curves were examined to test the relation between the detrapping rates and the stimulation light intensity. In SiO2, Al2O3 : C and BeO a linear relation between the detrapping rates....... The resultant OSL curve initially increases and then decays after reaching a maximum, The analysis of LM-OSL data usually assumes a linear relationship between the detrapping rate and the stimulation light intensity. However, experiments carried out using various insulators have shown that this assumption...

  1. Synthesis and TL/OSL properties of a novel high-sensitive blue-emitting LiSrPO{sub 4}:Eu{sup 2+} phosphor for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Palan, C.B.; Koparkar, K.A.; Omanwar, S.K. [Sant Gadge Baba Amravati University, Department of Physics, Amravati (India); Bajaj, N.S. [Toshniwal Arts, Commerce and Science College, Sengoan, Hingoli District, MH (India); Soni, A. [Bhabha Atomic Research Centre, Radiological Physics and Advisory Division, Mumbai (India)

    2016-07-15

    In this study, a series of Eu{sup 2+}-doped LiSrPO{sub 4} phosphors were synthesized via solid-state method. The structural and morphological characterizations were done through X-ray diffraction and scanning electronic microscope. Additionally, the photoluminescence (PL), thermoluminescence (TL) and optically stimulated luminescence (OSL) behaviours of LiSrPO{sub 4}:Eu{sup 2+} phosphors were studied. The LiSrPO{sub 4}:Eu{sup 2+} phosphor shows OSL sensitivity about 8 times than that of α-Al{sub 2}O{sub 3}:C phosphor and 6 times than that of LiMgPO{sub 4}:Tb{sup 3+}, B phosphor. Moreover, TL sensitivity was about 15 times more as compared to α-Al{sub 2}O{sub 3}:C phosphor. The kinetic parameters of TL curve were calculated using peak shape method. In TL/OSL mode, dose-response was almost linear nature, in the range of measurement. The minimum detectable dose was found to be 25.18 μGy with 3σ of background. Also, reusability was also studies, which shows the phosphor can be reusable for 10 cycles with 0.1 % change in OSL output. (orig.)

  2. Optically stimulated luminescence (OSL) from Ag-doped Li2B4O7 crystals

    International Nuclear Information System (INIS)

    Kananen, B.E.; Maniego, E.S.; Golden, E.M.; Giles, N.C.; McClory, J.W.; Adamiv, V.T.; Burak, Ya.V.; Halliburton, L.E.

    2016-01-01

    Optically stimulated luminescence (CW-OSL) is observed from Ag-doped lithium tetraborate (Li 2 B 4 O 7 ) crystals. Photoluminescence, optical absorption, and electron paramagnetic resonance (EPR) are used to identify the defects participating in the OSL process. As-grown crystals have Ag + ions substituting for Li + ions. They also have Ag + ions occupying interstitial sites. During a room-temperature exposure to ionizing radiation, holes are trapped at the Ag + ions that replace Li + ions and electrons are trapped at the interstitial Ag + ions, i.e., the radiation forms Ag 2+ (4d 9 ) ions and Ag 0 (4d 10 5s 1 ) atoms. These Ag 2+ and Ag 0 centers have characteristic EPR spectra. The Ag 0 centers also have a broad optical absorption band peaking near 370 nm. An OSL response is observed when the stimulation wavelength overlaps this absorption band. Specifically, stimulation with 400 nm light produces an intense OSL response when emission is monitored near 270 nm. Electrons optically released from the Ag 0 centers recombine with holes trapped at Ag 2+ ions to produce the ultraviolet emission. The OSL response is progressively smaller as the stimulation light is moved to longer wavelengths (i.e., away from the 370 nm peak of the absorption band of the Ag 0 electron traps). Oxygen vacancies are also present in the Ag-doped Li 2 B 4 O 7 crystals, and their role in the OSL process as a secondary relatively short-lived electron trap is described.

  3. Tl and OSL dosimetry of diamond films CVD pure and unpurified with boron-carbon; Dosimetria Tl y OSL de peliculas de diamante CVD puras e impurificadas con boro-carbono

    Energy Technology Data Exchange (ETDEWEB)

    Melendrez, R.; Pedroza M, M.; Chernov, V.; Ochoa N, J.D.; Bernal, R.; Barboza F, M. [CIF, UNISON, A.P. 5-088, 83190 Hermosillo, Sonora (Mexico); Castaneda, B. [Departamento de Fisica, Universidad de Sonora, Apdo. Postal 1626, Hermosillo, Sonora (Mexico); Goncalves, J.A.N.; Sandonato, G.M. [Laboratorio Associado de Plasma, Instituto Nacional de Pesquisas Espaciais C.P. 515- 12201 -970, Sao Jose dos Campos, SP (Brazil); Cruz Z, E. [Instituto de Ciencias Nucleares, UNAM, Apdo. Postal 70-543, 04510 Mexico D.F. (Mexico); Preciado F, S.; Cruz V, C.; Brown, F. [Departamento de Investigacion en Polimeros y Materiales de la Universidad de Sonora, Apdo. Postal 130, 83000 Hermosillo, Sonora (Mexico); Schreck, M. [Universitaet Augsburg, Institut fuer Physik D-86135 Augsburg (Germany)

    2004-07-01

    The diamond is a material that possesses extreme physical properties, such as its hardness to the radiation, its low chemical reactivity besides its equivalence to the human tissue, which qualify him as an ideal material for radiation dosimetry. In this work, it was studied the thermal and optically stimulated response (Tl and OSL) of polycrystalline diamond films grown by the technique of CVD pure and contaminated with Boron-carbon (B/C) with the intention of characterizing their efficiency like a dosemeter for radiation in a range of 0 - 3000 Gy. For the case of the films without impurities, the Tl curve presents four main peaks, two of them in an interval of temperatures of 150-200 C and other two additional around of 250-400 C. The dependence of the response of integrated Tl and that of OSL always maintained a lineal relationship with the exhibition dose up to 100 Gy. The behavior of the films contaminated with B/C (2000 - 20000 ppm) was established through experiments that involved the signal of OSL and their relationship with the Tl response. It was found that this processes are correlated, since the electrons caught in the traps of low temperature (50 - 250 C) of the Tl they are the electrons that recombining with more probability to provide the signal of OSL. According to these results it is possible to propose the diamond films as a good candidate for dosimetry to, using the traditional technique of Tl so much as well as the but recent of OSL. (Author)

  4. On the use of OSL of wire-bond chip card modules for retrospective and accident dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Woda, Clemens [Helmholtz Zentrum Muenchen - German Research Centre for Environmental Health, Institute of Radiation Protection, Ingolstaedter Landstrasse 1, D-85764 Neuherberg (Germany)], E-mail: clemens.woda@helmholtz-muenchen.de; Spoettl, Thomas [Infineon Technologies AG, Wernerwerkstrasse 1, D-93049 Regensburg (Germany)

    2009-05-15

    The potential of optically stimulated luminescence of wire-bond chip card modules, used in health insurance, ID, cash and credit cards for retrospective and accident dosimetry is investigated. Chip card modules obtained directly from the producer, using a widely spread UV-cured epoxy product for encapsulation, are used as basis for the study. The radiation sensitivity is due to silica grains added to the epoxy for controlling the thixotropic properties. Luminescence properties are complex due to the presumed thermo-optical release of electrons from the epoxy and transfer into the silica. Best results and highest sensitivity are obtained by using no or only low preheat treatments. A high degree of fading of the OSL signal during storage at room temperature is observed, which is tentatively explained by the superposition of thermal decay of shallow OSL traps and athermal (anomalous) decay of deeper OSL traps. The dose response of the OSL signal shows exponentially saturating behaviour, with saturation doses of 77 Gy or 9.6 Gy, depending on pretreatment. Dose recovery tests show that given doses can be recovered within a deviation of {+-}14%, if measured signals are corrected for fading. The minimum detectable dose is estimated at {approx}3 mGy, {approx}10 mGy and {approx}20 mGy for readouts immediately, 1 day and 10 days after exposure, respectively.

  5. On the use of OSL of wire-bond chip card modules for retrospective and accident dosimetry

    International Nuclear Information System (INIS)

    Woda, Clemens; Spoettl, Thomas

    2009-01-01

    The potential of optically stimulated luminescence of wire-bond chip card modules, used in health insurance, ID, cash and credit cards for retrospective and accident dosimetry is investigated. Chip card modules obtained directly from the producer, using a widely spread UV-cured epoxy product for encapsulation, are used as basis for the study. The radiation sensitivity is due to silica grains added to the epoxy for controlling the thixotropic properties. Luminescence properties are complex due to the presumed thermo-optical release of electrons from the epoxy and transfer into the silica. Best results and highest sensitivity are obtained by using no or only low preheat treatments. A high degree of fading of the OSL signal during storage at room temperature is observed, which is tentatively explained by the superposition of thermal decay of shallow OSL traps and athermal (anomalous) decay of deeper OSL traps. The dose response of the OSL signal shows exponentially saturating behaviour, with saturation doses of 77 Gy or 9.6 Gy, depending on pretreatment. Dose recovery tests show that given doses can be recovered within a deviation of ±14%, if measured signals are corrected for fading. The minimum detectable dose is estimated at ∼3 mGy, ∼10 mGy and ∼20 mGy for readouts immediately, 1 day and 10 days after exposure, respectively.

  6. OSL dating of sediments from Negro and Solimões rivers – Amazon, Brazil

    International Nuclear Information System (INIS)

    Fiore, M.; Soares, E.A.A.; Mittani, J.C.R.; Yee, M.; Tatumi, S.H.

    2014-01-01

    In this work, the OSL dating results of Quaternary fluvial deposits from the confluence of Negro and Solimões rivers were studied. The equivalent doses (D e ) of sediments were obtained using a Single Aliquot Regeneration (SAR) protocol. Statistic studies were made using frequency histogram, weighted histogram and Radial plot in order to analyze the D e fluctuations. Ages from 74.5 to 205 thousand of years (Pleistocene) were recorded. The gamma-ray spectroscopy was used to evaluate the natural radioisotopes concentrations of the samples and low concentrations were found with values between 0.64 and 3.71 ppm for 235 U and 238 U; 2.01–9.77 ppm for 232 Th; already, for 40 K, the concentration was negligible. The OSL dating of sediments has contributed to a better understanding of the evolution of Negro and Solimões rivers, in Amazon, Brazil. - Highlights: ► OSL dating of fluvial terraces from Amazon. ► SAR protocols applied to Amazon sediments dating. ► OSL dating of Solimão and Negro rivers sediments

  7. Mechanical properties of rubberwood oriented strand lumber (OSL: The effect of strand length

    Directory of Open Access Journals (Sweden)

    Buhnnum Kyokong

    2005-09-01

    Full Text Available Effect of strand length on mechanical properties (tension, compression and bending of oriented strand lumber (OSL made of rubberwood (Hevea brasiliensis Muell. Arg. was reported. Three strand lengths of 50 mm, 100 mm, and 150 mm with 1 mm thickness and 15 mm width were used. The strands were mixed with 5% pMDI glue (weight basis in a tumble mixer. The OSL specimens were formed by hot pressing process of unidirectionally aligned strands. Average specific gravity and moisture content were 0.76 and 8.34%, respectively. Tension and compression tests were carried out for directions both parallel and perpendicular to grain while bending test was performed only in parallel direction. Ultimate stresses and moduli of elasticity were examined from the stress-strain curves. It was found that for the parallel-to-grain direction, the longer strand OSL gave higher strength. The role of the strand length did not appear for the direction normal to the grain. The relationship between the mechanical properties of OSL and strand length was well described by the modified Hankinson formula.

  8. BeO-OSL detectors for dose measurements in cell cultures

    International Nuclear Information System (INIS)

    Andreeff, M.; Freudenberg, R.; Kotzerke, J.; Sommer, D.; Reichelt, U.; Henniger, J.

    2009-01-01

    Aim: The absorbed dose is an important parameter in experiments involving irradiation of cells in vitro with unsealed radionuclides. Typically, this is estimated with a model calculation, although the results thus obtained cannot be verified. Generally used real-time measurement methods are not applicable in this setting. A new detector material with in vitro suitability is the subject of this work. Methods: Optically-stimulated luminescence (OSL) dosimeters based on beryllium oxide (BeO) were used for dose measurement in cell cultures exposed to unsealed radionuclides. Their qualitative properties (e. g. energy-dependent count rate sensitivity, fading, contamination by radioactive liquids) were determined and compared to the results of a Monte Carlo simulation (using AMOS software). OSL dosimeters were tested in common cell culture setups with a known geometry. Results: Dose reproducibility of the OSL dosimeters was ± 1.5%. Fading at room temperature was 0.07% per day. Dose loss (optically-stimulated deletion) under ambient lighting conditions was 0.5% per minute. The Monte Carlo simulation for the relative sensitivity at different beta energies provided corresponding results to those obtained with the OSL dosimeters. Dose profile measurements using a 6 well plate and 14 ml PP tube showed that the geometry of the cell culture vessel has a marked influence on dose distribution with 188 Re. Conclusion: A new dosimeter system was calibrated with β-emitters of different energy. It turned out as suitable for measuring dose in liquids. The dose profile measurements obtained are suitably precise to be used as a check against theoretical dose calculations. (orig.)

  9. The fast ratio: A rapid measure for testing the dominance of the fast component in the initial OSL signal from quartz

    International Nuclear Information System (INIS)

    Durcan, Julie A.; Duller, Geoff A.T.

    2011-01-01

    The signal from the fast component is usually considered preferable for quartz optically stimulated luminescence (OSL) dating, however its presence in a continuous wave (CW) OSL signal is often assumed, rather than verified. This paper presents an objective measure (termed the fast ratio) for testing the dominance of the fast component in the initial part of a quartz OSL signal. The ratio is based upon the photo ionisation cross-sections of the fast and medium components and the power of the measurement equipment used to record the OSL signal, and it compares parts of the OSL signal selected to represent the fast and medium components. The ability of the fast ratio to distinguish between samples whose CW-OSL signal is dominated by the fast and non-fast components is demonstrated by comparing the fast ratio with the contribution of the fast component calculated from curve deconvolution of measured OSL signals and from simulated data. The ratio offers a rapid method for screening a large number of OSL signals obtained for individual equivalent dose estimates, it can be calculated and applied as easily as other routine screening methods, and is transferrable between different aliquots, samples and measurement equipment. - Highlights: → Fast ratio is a measure which tests dominance of fast component in quartz OSL signals. → A fast ratio above 20 implies a CW-OSL signal is dominated by fast component. → Fast ratio can be easily and rapidly applied to a large number of OSL signals. → Uses include signal comparison, data screening, identify need for further analysis.

  10. Preliminary results on TL and OSL aluminium oxide dosimeters developed at IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Fukumori, David T.; Yoshito, Walter K.; Ussui, Valter; Lazar, Dolores R.R.; Campos, Leticia L., E-mail: fukumori@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The aluminum oxide composes the modern TL and OSL radiation dosimeters. TL and OSL phenomena are related to chemical elements in the crystalline structure of {alpha}-Al{sub 2}O{sub 3}. The aim of this work was to develop materials based on aluminum oxide for use in TL and OSL dosimetry. The studies included the dosimetric properties of alumina samples obtained by electro fusion, adsorption and coprecipitation. Electro fused alumina commercially available as abrasive particles was used to produce the pellets by glass sintering. Adsorption and coprecipitation were the methods used to insert metal ions to alumina. The best results were achieved with electro fused alumina and Tm{sup 3+} doped Al{sub 2}O{sub 3} pellets. The electro fused alumina-glass pellets show TL and OSL signals and the TL curve has two peaks. Its minimum detectable radiation dose is 7.2 mGy and the linearity of TL response as function of dose is up to about 800 mGy. The {alpha}-Al{sub 2}O{sub 3}:Tm pellets produced by sintering at 1550 deg C presented a meaningful TL glow curve so that it is worth studying their properties and viability of use in dosimetry. (author)

  11. OSL and TL retrospective dosimetry with a fluorapatite glass-ceramic used for dental restorations

    International Nuclear Information System (INIS)

    Ekendahl, Daniela; Judas, Libor; Sukupova, Lucie

    2013-01-01

    Optically Stimulated Luminescence (OSL) and Thermoluminescence (TL) properties of a fluorapatite glass-ceramic have been investigated, with a view to developing a dose assessment technique for medical triage following unplanned exposures of individuals to ionizing radiation. The ceramic is an innovative material used in dental prostheses and restorations. It is strongly sensitive to radiation and the intensity of both the OSL and TL signals are proportional to the absorbed radiation dose. We focused on the optimization of the measuring procedure and investigated characteristics such as reproducibility, fading, minimum detectable dose (MDD), dose response and photon energy response of TL and OSL signals. The dental ceramic exhibited very good reproducibility (<5% at 2σ level) when measured and a linear dose response for a wide range of doses (50 mGy–20 Gy). The MDD values for the samples investigated were ∼5 mGy. The material is not tissue equivalent and the OSL and TL signals are strongly dependent on incident photon energy. Both the luminescence signals exhibited significant fading during the first few hours after irradiation. Its rate was dependent on the parameters of measurement. The results indicate that the material can be used for the purposes of accident dosimetry, however, the fading and photon energy response have to be properly corrected for a reliable dose assessment. - Highlights: ► A dental ceramic was considered as a retrospective and accident dosimeter. ► Dosimetry application was investigated using OSL and TL. ► TL and OSL signals are proportional to absorbed radiation dose. ► Accuracy is dependent on correction of fading and photon energy response

  12. Thermal activation of OSL as a geothermometer for quartz grain heating during fault movements

    International Nuclear Information System (INIS)

    Rink, W.J.; Toyoda, S.; Rees-Jones, J.; Schwarcz, H.P.

    1999-01-01

    In discussions of ESR dating of fault movements, there has been much debate whether zeroing of ESR signals is a mechanical shearing effect or caused by frictional heating. The OSL (optically stimulated luminescence) sensitivity of quartz is known to increase after heating. This thermal activation of dose response of the OSL in quartz should be useful as a geothermometer to test whether quartz particles in fault gouge had been heated. We tested the OSL sensitivities of quartz from fault gouge, and from a control (quartz grains from sandstone) and were able to show heat-induced enhancement of OSL sensitivity to a test dose. We observed that relative enhancement of OSL dose response (ratio of heated to unheated single aliquots) is significantly less for the finest grains (45-75 and 100-150 μm) compared with coarser grains (150-250 μm). These data are consistent with a model of zeroing of the quartz grains during faulting, by frictional heating localized to the grain boundaries, which would be expected to affect smaller grains more than large ones. This argues against a zeroing model in which the entire fault gouge is heated by friction. Higher laboratory preheating of sandstone quartz reduces between-aliquot variability of OSL dose response in the unheated grains to nearly zero. Unheated coarsest fault gouge grains displayed virtually no among-aliquot variability, whereas fine grains showed much larger between-aliquot variability; as with the quartz sand, variability dropped to near zero after laboratory heating, suggesting that fine grains in fault gouge have experienced a wide range of natural thermal histories during faulting. This may present a problem for ESR dating of fault gouge using the plateau method

  13. Application of the OSL dosimetry technique in the identification of irradiated foods, such as condiments and spices

    International Nuclear Information System (INIS)

    Silva, Catherine C.O.; Alencar, Marcus A.V. de

    2013-01-01

    The use of ionizing radiation in food preservation is considered a well-established technique, so many countries, including Brazil, now allow the use of irradiated foods. Many methods have been tested for dosimetry and identification of irradiated foods including thermoluminescence, electron paramagnetic resonance, and others based on microbiological changes and in viscosity, and which requires a sample processing. The technique of optically stimulated luminescence (OSL) presents an advantage over other methods mentioned: The samples may be used without the need for a prior processing. This work aims to study the OSL properties of condiments and spices irradiated, in order to verify the possibility of the application of the OSL technique in identifying and dosimetry of irradiated foods. The samples used were of four kinds of spices: cumin, oregano, white pepper and black pepper. All samples were subjected to gamma irradiation from a Co-60 source with dose values of kerma in air of 100 Gy to 35 kGy. The samples of cumin presents the OSL signal, however, is only possible to identify whether the condiment was irradiated or not. The sample of oregano also presents the OSL signal, and for this condiment is possible to identify addition to its irradiation, the value of dose. The black pepper and white pepper samples don't presents the OSL signal. The results obtained in this study indicate the possibility of using the OSL technique for the identification and dosimetry of irradiated foods. (author)

  14. Quartz OSL Dating of the loess deposit in the eastern Tibetan Plateau and its environment implications since the Last Glaciation

    Science.gov (United States)

    Yang, S.; Cheng, T.; Liu, W.; Fang, X.

    2017-12-01

    Loess deposit is widespread in the Chuanxi Plateau, the eastern Tibetan Plateau, which is a critical archive for understanding the aeolian process, the evolution of the westerly and the environment changes on the Plateau. Previous studies have shown its aeolian origin, and mainly transported by wind from the western part of the Tibetan Plateau. However, the aeolian processes of the loess and its environment implications are not well understood mainly due to lack of detailed age controls. We carry out a combined quartz optically stimulated luminescence (OSL) dating and accelerator mass spectrometry radiocarbon dating (AMS 14-C) for the loess deposits in Garzê and Jinchuan. The results indicate that the quartz OSL dating can provide reliable age controls for the loess-paleosol sequences from the Chuanxi Plateau, showing the potential of OSL to date loess in the high altitude region. The results indicate that the OSL ages are in agreement with the observed stratigraphy in the field. The constructed OSL and AMS 14-C chronology of the Garzê loess reveals that the widespread loess in Ganzi Region deposited since the Last Glacial. The dust accumulation is rapid during marine isotope stage (MIS) 3 and 2, and a relative low accumulation rate in the Holocene, which may related with the desertification processes of the inner Tibetan Plateau.

  15. Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors

    International Nuclear Information System (INIS)

    Karsch, L.; Beyreuther, E.; Burris-Mog, T.; Kraft, S.; Richter, C.; Zeil, K.; Pawelke, J.

    2012-01-01

    Purpose: The use of laser accelerators in radiation therapy can perhaps increase the low number of proton and ion therapy facilities in some years due to the low investment costs and small size. The laser-based acceleration technology leads to a very high peak dose rate of about 10 11 Gy/s. A first dosimetric task is the evaluation of dose rate dependence of clinical dosimeters and other detectors. Methods: The measurements were done at ELBE, a superconductive linear electron accelerator which generates electron pulses with 5 ps length at 20 MeV. The different dose rates are reached by adjusting the number of electrons in one beam pulse. Three clinical dosimeters (TLD, OSL, and EBT radiochromic films) were irradiated with four different dose rates and nearly the same dose. A faraday cup, an integrating current transformer, and an ionization chamber were used to control the particle flux on the dosimeters. Furthermore two diamond detectors were tested. Results: The dosimeters are dose rate independent up to 410 9 Gy/s within 2% (OSL and TLD) and up to 1510 9 Gy/s within 5% (EBT films). The diamond detectors show strong dose rate dependence. Conclusions: TLD, OSL dosimeters, and EBT films are suitable for pulsed beams with a very high pulse dose rate like laser accelerated particle beams.

  16. On the OSL curve shape and preheat treatment of electronic components from portable electronic devices

    DEFF Research Database (Denmark)

    Woda, Clemens; Greilich, Steffen; Beerten, Koen

    2010-01-01

    The shape of the OSL decay curve and the effect of longer time delays between accidental exposure and readout of alumina-rich electronic components from portable electronic devices are investigated. The OSL decay curve follows a hyperbolic decay function, which is interpreted as an approximation ...

  17. TL and OSL studies on lithium borate single crystals doped with Cu and Ag

    International Nuclear Information System (INIS)

    Rawat, N.S.; Kulkarni, M.S.; Tyagi, M.; Ratna, P.; Mishra, D.R.; Singh, S.G.; Tiwari, B.; Soni, A.; Gadkari, S.C.; Gupta, S.K.

    2012-01-01

    Lithium borate (LBO) single crystals doped with Cu and Ag (0.25 mol% each) (Li 2 B 4 O 7 :Cu,Ag) are grown by the Czochralski method. The thermoluminescence readout on Li 2 B 4 O 7 :Cu,Ag crystals showed three glow peaks at∼375, 441 and 516 K for the heating rate of 1 K/s. The thermoluminescence sensitivity of the grown Li 2 B 4 O 7 :Cu,Ag single crystals is found to be 5 times TLD-100 and a linear dose response in the range 1 mGy to 1 kGy. The glow curve deconvolution reveals nearly first order kinetics for all the three peaks with trap depths 0.77, 1.25 and 1.34 eV respectively and corresponding frequency factors 1.6×10 9 , 1.3×10 13 and 6.8×10 11 s −1 . The continuous wave optically stimulated luminescence (CW-OSL) measurements were performed on the LBO:Cu,Ag single crystals using blue light stimulation. The traps responsible for the three thermoluminescence peaks in Li 2 B 4 O 7 :Cu,Ag are found to be OSL sensitive. The qualitative correlation between TL peaks and CW-OSL response is established. The photoluminescence studies show that in case of co-doping of Ag in LBO:Cu the emission at 370 nm in Cu states dominates over the transitions in Ag states implying doping of Ag plays a role as sensitizer when co-doped with Cu and increases overall emission. - Highlights: ► Growth of crack free single crystals of Li2B4O7 :Cu and Ag. ► Study of TL and OSL parameters for Li2B4O7 :Cu and Ag. ► Correlation of OSL with TL peaks. ► Optimization of OSL readout time with respect to residual TL.

  18. Pulse and integral optically stimulated luminescence (OSL). Similarities and dissimilarities to thermoluminescence (TL) dose dependence and dose-rate effects

    International Nuclear Information System (INIS)

    Chen, R.; Leung, P.L.

    2000-01-01

    Optically stimulated luminescence (OSL) and thermoluminescence (Tl) are two possible methods to monitor the absorbed radiation in solid samples, and therefore are utilized for dosimetry. For this application, two properties are desirable, namely, linear dose dependence of the measured quantity and dose-rate independence. For Tl, different kinds of super linear dose dependence have been reported in the literature in different materials, and in some cases, dose-rate dependence has also been found. These have been explained as being the result of competition. In OSL, some recent works reported on super linear dose dependence in annealed samples. In the present work, we explain the possible occurrence of these phenomena in OSL by solving numerically the relevant rate equations governing the process during irradiation, relaxation and read-out (heating or light stimulation). The results show that for short pulse OSL, quadratic dose dependence can be expected when only one trapping state and one kind of recombination center are involved and when the excitation starts with empty traps and centers. With the short pulse OSL, the calculation also reveals a possible dose-rate effect. Under the same circumstances, the area under the OSL curve depends linearly on the dose. The dependence of the whole area under the OSL curve on the dose is shown to be super linear when a disconnected trapping state or radiationless center take part in the process. Also, dose-rate effect can be expected in these cases, although no experimental effect of this sort has been reported so far. In pulse OSL, the analogy is made between the measured intensity and the initial rise range of non-first order Tl, whereas for the total area OSL, there is a nearly full analogy with the dose behavior of the Tl maximum. (Author)

  19. Mortar and surface dating with Optically Stimulated Luminescence (OSL): Innovative techniques for the age determination of buildings

    International Nuclear Information System (INIS)

    Panzeri, L.

    2013-01-01

    In this work the results of a dating study on bricks and mortars using both Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) are shown. The samples came from the outside walls of the Certosa di Pavia, located in northern Italy and independently dated (XVII-XVIII century). TL dating, applied to bricks using the fine grain technique, allowed to determine the time of manufacture of the bricks (XII century), that resulted therefore re-used. To circumvent this problem the application of two innovative dating techniques, OSL surface dating and mortar dating, was attempted. The first was applied to the light-shielded surfaces of bricks and allowed to successfully determine the edification of the wall (XVII century). Mortar dating gave instead severe age overestimation: the results obtained on coarse grain quartz with the SAR technique both on multi-grains aliquots and with single-grain analyses were highly dispersed indicating an incomplete bleaching of the quartz grains. The shine-down curves were in fact characterized by the absence of the so-called fast component, as confirmed by Linear Modulated OSL technique.

  20. Online fibre optic OSL in vivo dosimetry for quality assurance of external beam radiation therapy treatments: The ANR-TECSAN Codofer Project

    International Nuclear Information System (INIS)

    Magne, S.; Ferdinand, P.; De Carlan, L.; Bridier, A.; Isambert, A.; Hugon, R.; Guillon, J.

    2010-01-01

    The Codofer Project (2007-2009), led under the ANR-TECSAN Call, was coordinated by CEA LIST, in partnership with IGR and the Fimel company. The aim of the project was to design and test both metrologically and in clinical conditions OSL optical fiber sensors dedicated to in vivo dosimetry during external beam radiation therapy treatment with high-energy electrons. This study, combined with the results of clinical tests obtained within the European Project Maestro, has demonstrated the advantages of OSL/FO dosimetry for providing quality assurance of treatments. However, the French market for dosimetry has greatly changed as a result of the rules decreed by the French government in 2007. The OSL/FO product is now targeted for other treatment modalities lacking suitable dosimeters (ANR-INTRADOSE Project [2009-2011]). (authors)

  1. Potential and limits of OSL, TT-OSL, IRSL and pIRIR290 dating methods applied on a Middle Pleistocene sediment record of Lake El'gygytgyn, Russia

    Directory of Open Access Journals (Sweden)

    A. Zander

    2013-03-01

    Full Text Available This study tests the paleomagnetic and proxy-data based Mid- to Upper Pleistocene sediment deposition history of Lake El'gygytgyn by applying different approaches of luminescence dating techniques on sediment cores taken from the centre of the 175 m deep lake. For dating polymineral and quartz fine grains (4–11 μm grain size range were extracted from nine different levels from the upper 28 m of sediment cores 5011-1A and 5011-1B. According to the independent age model, the lowest sample from 27.8–27.9 m below lake bottom level correlates to the Brunhes-Matuyama (B/M reversal. Polymineral sub-samples were analysed by infra-red stimulated luminescence (IRSL and post-IR IRSL measured at 290 °C (pIRIR290 using single aliquot regenerative dose (SAR sequences. SAR protocols were further applied to measure the blue light optically stimulated luminescence (OSL and thermally-transferred OSL (TT-OSL of fine-grained quartz supplemented by a multiple aliquot approach. Neither low temperature IRSL measurements at 50 °C nor any OSL dating approach on quartz yielded reliable results. Deconvolution of their dose response curves revealed a pseudo-increase of the dose response curves and explains the observed underestimation. The pIRIR protocol applied to polymineral fine grains was the only luminescence technique able to provide dating results of acceptable accuracy up to ca. 700 ka when correlated to the existing proxy-data and paleomagnetic based age record. We present the potential and limits of the different dating techniques and a correlation of pIRIR290 results with the proxy-data based age model.

  2. Optical stimulated luminescence (OSL) dating

    International Nuclear Information System (INIS)

    Banerjee, D.

    1999-01-01

    Since the pioneering work by Huntley et al. (1985), optical dating is being increasingly recognised as an important technique for establishing a time frame of deposition of sediments (Aitken, 1998). Optical dating differs from thermoluminescence (TL) dating in that visible/infrared light from lasers or LEDs (light-emitting-diodes) is used as a means of stimulation, in contrast to thermal stimulation. It has several advantages over TL dating: (i) the resetting of the OSL (optically stimulated luminescence) clock is more effective than that of TL clock; for sediments transported under water or in other situations where the sediment grains have undergone inhomogeneous bleaching, this property ensures that ages based on optical dating are generally more reliable than TL ages, (ii) the optical dating technique is non-destructive, and multiple readouts of the optical signal is possible; this feature has resulted in the development of single-aliquot and single-grain protocols (Murray and Wintle, 1999; Banerjee et al. 1999), (iii) the sample is not heated as in TL; thus, spurious luminescence is avoided and there is a significant reduction in blackbody radiation. Dating of materials which change phase on heating is also practical, and finally, (iv) thermal quenching of luminescence is negligible, allowing accurate estimation of kinetic parameters using standard techniques and providing access to deep OSL traps. This characteristic may be helpful in extending the limits of optical dating beyond the last 150 ka from a global point of view

  3. Tl and OSL dosimetry of diamond films CVD pure and unpurified with boron-carbon

    International Nuclear Information System (INIS)

    Melendrez, R.; Pedroza M, M.; Chernov, V.; Ochoa N, J.D.; Bernal, R.; Barboza F, M.; Castaneda, B.; Goncalves, J.A.N.; Sandonato, G.M.; Cruz Z, E.; Preciado F, S.; Cruz V, C.; Brown, F.; Schreck, M.

    2004-01-01

    The diamond is a material that possesses extreme physical properties, such as its hardness to the radiation, its low chemical reactivity besides its equivalence to the human tissue, which qualify him as an ideal material for radiation dosimetry. In this work, it was studied the thermal and optically stimulated response (Tl and OSL) of polycrystalline diamond films grown by the technique of CVD pure and contaminated with Boron-carbon (B/C) with the intention of characterizing their efficiency like a dosemeter for radiation in a range of 0 - 3000 Gy. For the case of the films without impurities, the Tl curve presents four main peaks, two of them in an interval of temperatures of 150-200 C and other two additional around of 250-400 C. The dependence of the response of integrated Tl and that of OSL always maintained a lineal relationship with the exhibition dose up to 100 Gy. The behavior of the films contaminated with B/C (2000 - 20000 ppm) was established through experiments that involved the signal of OSL and their relationship with the Tl response. It was found that this processes are correlated, since the electrons caught in the traps of low temperature (50 - 250 C) of the Tl they are the electrons that recombining with more probability to provide the signal of OSL. According to these results it is possible to propose the diamond films as a good candidate for dosimetry to, using the traditional technique of Tl so much as well as the but recent of OSL. (Author)

  4. The correlation of fast OSL component with the TL peak at 3250C in quartz of various origins

    International Nuclear Information System (INIS)

    Kitis, G.; Kiyak, N.; Polymeris, G.S.; Tsirliganis, N.C.

    2010-01-01

    The fast component of the optically stimulated luminescence (OSL) signal in quartz is the basic tool for the optical dating. Its relation with the thermoluminescence (TL) glow-peak at about 325 deg. C is well established for naturally irradiated quartz. This relationship is also an important part of a general model for quartz on which many theoretical simulations of various OSL experimental results have been based. In the present work this relationship is systematically investigated in nine quartz samples of different origin. The linearly modulated OSL (LM-OSL) curves of all quartz samples for stimulation time less than 50 s consists of two components discriminated easily by a computerized curve deconvolution (CCD) analysis. By comparing the un-bleached to the respective bleached TL glow-curve, it is found that the system of these two fast OSL components is directly related with only a small portion of the electron traps responsible for the TL glow-peaks in the temperature region 200-400 0 C. By increasing the stimulation times, besides the two fast components, the medium and the slow components are also obtained. The medium and slow components are clearly related with the main body of the electron traps responsible for TL glow-peaks in the same temperature region 200-400 0 C. Despite their different origin all quartz samples show an appreciable homogeneity concerning the number and time position of the individual components, whereas, the relative TL/OSL intensities vary strongly from sample to sample with the integrated TL intensity being generally much less than the integrated OSL intensity.

  5. Introduction of a new dosimetry system based on optically stimulated luminescence (OSL) in our personal monitoring service

    International Nuclear Information System (INIS)

    Hubner, S.

    2014-08-01

    The personal monitoring service named Auswertungsstelle is part of the Helmholtz Zentrum Munchen, a non-profit-making research center in Germany. As one of the four monitoring services in Germany, we have been a reliable partner in radiation protection for more than 60 years. With about 1.9 million dose assessments per year, we are the largest monitoring service in Europe. For dozens of years, our main dosimeter used in whole-body dosimetry has been a film dosimeter. Although its dosimetric properties are still up to date, film dosimetry won.t be a sustainable technique for the use in monitoring services. Therefore, a project with the objective of investigating alternative dosimetric materials and methods was launched in the late 1990 at the Helmholtz Zentrum Munchen. Based on this research work, the use of Be O as an OSL dosimeter was studied by the radiation physics group of the Tu Dresden, by order and on account of the Auswertungsstelle at the Helmholtz Zentrum Munchen. It was shown, that ceramic Be O features promising dosimetric properties, making Be O detectors particularly suitable for being used in all applications in whole-body dosimetry measuring photons. Ceramic Be O material has an excellent resistance to environmental influences. The Be O chips are almost tissue equivalent. Therefore, these detectors show low photon energy dependence. A new personal dosimetry system based on the OSL dosimetry of Be O was developed. Applying this system, the Auswertungsstelle offers OSL-dosimeters for official monitoring of the Personal Dose Equivalent Hp(10) since 2011. This OSL-System is accredited according to DIN IEC 62387 and we obtained the corresponding type approval by the Ptb, the national metrology institute in Germany. Sophisticated logistics was developed and installed. High degree of automation was achieved by robots for dosimeter assembly and machines for packing, labelling and unpacking of the dosimeters. To become a sustainable dosimetry system not only

  6. Introduction of a new dosimetry system based on optically stimulated luminescence (OSL) in our personal monitoring service

    Energy Technology Data Exchange (ETDEWEB)

    Hubner, S., E-mail: stephan.huebner@helmholtz-muenchen.de [Helmholtz Zentrum Munchen, German Research Center for Environmental Health, D-80219, Munich (Georgia)

    2014-08-15

    The personal monitoring service named Auswertungsstelle is part of the Helmholtz Zentrum Munchen, a non-profit-making research center in Germany. As one of the four monitoring services in Germany, we have been a reliable partner in radiation protection for more than 60 years. With about 1.9 million dose assessments per year, we are the largest monitoring service in Europe. For dozens of years, our main dosimeter used in whole-body dosimetry has been a film dosimeter. Although its dosimetric properties are still up to date, film dosimetry won.t be a sustainable technique for the use in monitoring services. Therefore, a project with the objective of investigating alternative dosimetric materials and methods was launched in the late 1990 at the Helmholtz Zentrum Munchen. Based on this research work, the use of Be O as an OSL dosimeter was studied by the radiation physics group of the Tu Dresden, by order and on account of the Auswertungsstelle at the Helmholtz Zentrum Munchen. It was shown, that ceramic Be O features promising dosimetric properties, making Be O detectors particularly suitable for being used in all applications in whole-body dosimetry measuring photons. Ceramic Be O material has an excellent resistance to environmental influences. The Be O chips are almost tissue equivalent. Therefore, these detectors show low photon energy dependence. A new personal dosimetry system based on the OSL dosimetry of Be O was developed. Applying this system, the Auswertungsstelle offers OSL-dosimeters for official monitoring of the Personal Dose Equivalent Hp(10) since 2011. This OSL-System is accredited according to DIN IEC 62387 and we obtained the corresponding type approval by the Ptb, the national metrology institute in Germany. Sophisticated logistics was developed and installed. High degree of automation was achieved by robots for dosimeter assembly and machines for packing, labelling and unpacking of the dosimeters. To become a sustainable dosimetry system not only

  7. The dependence of dose recovery experiments on the bleaching of natural quartz OSL using different light sources

    International Nuclear Information System (INIS)

    Choi, J.H.; Murray, A.S.; Cheong, C.-S.; Hong, S.C.

    2009-01-01

    In this paper, the dependence of dose recovery tests on the different bleaching light sources (blue-LEDs, solar simulator, natural sunlight) is investigated with a variety of sedimentary quartz samples, selected so that their OSL signals are dominated by the fast OSL component. We observed that when long solar simulator bleaching was applied, various known doses were underestimated in an SAR-based dose recovery test. However, when blue-LEDs and short solar simulator bleaching were used (10 s and 60 s) the known doses were accurately recovered. In repeated measurement of the OSL signals induced by the same regeneration and test dose, we observed a considerable increase in quartz OSL sensitivity during or after the first OSL measurement when long solar simulator bleaching was used; this seems to provide a possible explanation for the observed underestimation of the laboratory known doses. A series of experimental results using a sample from a modern aeolian dune surface shows that there are no subsequent sensitivity changes when the naturally zeroed samples are bleached with sunlight for long time. It seems that there is a dependence of the sensitivity change on the amount of dose administered before solar simulator bleaching and on the light intensity of solar simulator. When small doses were given to the naturally zeroed sample, the sensitivity change during or after the first OSL measurement was not significant. However, when a considerable amount of beta dose (∼4000 Gy) is administered to the sample, a clear sensitivity change during or after the first OSL measurement (∼20%) was observed. Such a sensitivity change was not observed when the bleaching light intensity of solar simulator was reduced by increasing the distance between samples and the UV lamp. Our results show that, at least for the samples described here, the outcomes of dose recovery experiments are dependent on the bleaching conditions.

  8. TL/OSL properties of natural schist for archaeological dating and retrospective dosimetry

    International Nuclear Information System (INIS)

    Afouxenidis, D.; Stefanaki, E.C.; Polymeris, G.S.; Sakalis, A.; Tsirliganis, N.C.; Kitis, G.

    2007-01-01

    Schist, a metamorphic rock composed largely of quartz and muscovite, has been used as a building stone through the centuries in many parts of the world. In ancient Greece, it was used in buildings and monuments (Knossos, Karthaia, etc). Basic TL and OSL properties of schist are studied in the present work to evaluate its potential use in archaeological dating and retrospective dosimetry. In particular, the optical stability, as well as the linearity of the TL and OSL signal were investigated for samples of natural schist obtained from a roofing slate. The results indicate that both signals are rapidly bleached when the sample is exposed to sunlight. An exposure of 1 min reduces the TL signal by 93%, the IRSL signal by 99% and the post-IR BSL signal by 90%. The dose response was found to be linear for a radiation dose at least up to 75 Gy for the TL and the IR OSL signal and at least up to 25 Gy for the post-IR BSL signal

  9. Pilot study: relative dose of the TLD, OSL and Radiochromic film applied in CT exams dosimetry

    International Nuclear Information System (INIS)

    Kikuti, C.F.; Maia, R.S.I.; Romano, R.F.T.; Daros, K. A.C.

    2015-01-01

    At DDI/UNIFESP, the abdomen and chest CT exams correspond to 38% of the exams, becoming the focus of studies. The aim of this study is to assess the relative dose using TLDs, OSLs and RF for the evaluation of the dose distribution in the skin in abdomen CT exams. The simulation of the CT exam was performed in an anthropomorphic phantom, using a CT scanner Philips, Brilliance/64 and TLDs, OSLs and RF fixed along the sagittal axis of the phantom. The OSLs showed similar performance to the TLDs and RF shows low accuracy, resulting in an average value (0.927±0.022). (author)

  10. Pilot study: relative dose of the TLD, OSL and Radiochromic film applied in CT exams dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kikuti, C.F. [Universidade Federal do Mato Grosso do Sul (UFMS), Campo Grande, MS (Brazil). Hospital Universitario Maria Aparecida Pedrossian; Maia, R.S.I.; Romano, R.F.T.; Daros, K. A.C., E-mail: daros.kellen@unifesp.br [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Departamento de Diagnostico por Imagem

    2015-07-01

    At DDI/UNIFESP, the abdomen and chest CT exams correspond to 38% of the exams, becoming the focus of studies. The aim of this study is to assess the relative dose using TLDs, OSLs and RF for the evaluation of the dose distribution in the skin in abdomen CT exams. The simulation of the CT exam was performed in an anthropomorphic phantom, using a CT scanner Philips, Brilliance/64 and TLDs, OSLs and RF fixed along the sagittal axis of the phantom. The OSLs showed similar performance to the TLDs and RF shows low accuracy, resulting in an average value (0.927±0.022). (author)

  11. Retrospective radiation dosimetry using OSL of electronic components: Results of an inter-laboratory comparison

    International Nuclear Information System (INIS)

    Bassinet, C.; Woda, C.; Bortolin, E.; Della Monaca, S.; Fattibene, P.; Quattrini, M.C.; Bulanek, B.; Ekendahl, D.; Burbidge, C.I.; Cauwels, V.; Kouroukla, E.; Geber-Bergstrand, T.; Mrozik, A.; Marczewska, B.; Bilski, P.; Sholom, S.; McKeever, S.W.S.; Smith, R.W.; Veronese, I.

    2014-01-01

    In the framework of the EU-FP7 MULTIBIODOSE project, two protocols using OSL of resistors removed from the circuit board of mobile phones were developed with the aim to use the resistors as fortuitous dosimeters in the event of a large scale radiological accident. This paper presents the results of an inter-laboratory comparison carried out under the umbrella of EURADOS. The two aims of this exercise were the validation of the MULTIBIODOSE protocols by a large number of laboratories and the dissemination of the method with the objective of preparing the basis for a network that could increase Europe's response capacity in the case of a mass casualty radiological emergency. Twelve institutes from eleven European countries and one institute from the USA, with various degrees of expertise in OSL dosimetry, took part in the OSL inter-laboratory comparison. Generally, a good agreement within uncertainties was observed between estimated and nominal doses. - Highlights: • Resistors in mobile phones could function as reliable fortuitous dosimeters in case of a large scale radiological accident. • Two OSL protocols were validated by an inter-laboratory comparison. • It is feasible to set up a network of laboratories so as to increase the measurement capacity

  12. Optically stimulated luminescence (OSL) and some other luminescence images from granite slices exposed with radiations

    International Nuclear Information System (INIS)

    Hashimoto, T.; Notoya, S.; Ojima, T.; Hoteida, M.

    1995-01-01

    Optically stimulated luminescence (OSL) images of some X- and γ-irradiated granite slices were obtained using photon detection through a 570 nm bandpass filter with diode-laser excitation of 910 nm. Alternative photo-induced phosphorescence (PIP) images, which were colour photographed immediately after the sunlight exposure of slice samples, were also found to be helpful in the observation of the luminescence properties and to filter selection for OSL measurements. These OSL and PIP images were compared with some other colour luminescence images, including thermoluminescence images (TLCI) and after-glow images (AGCI). It was obvious that there exists a variety of coloured emissions derived mainly from feldspar constituents and these were found to be dependent on the geological history or metamorphism of the granites. (Author)

  13. A single-aliquot regenerative-dose method based on IR (1.49 eV) bleaching of the fast OSL component in quartz

    DEFF Research Database (Denmark)

    Jain, M.; Murray, A.S.; Bøtter-Jensen, L.

    2005-01-01

    In the optically stimulated luminescence (OSL) dating of quartz, the presence of significant medium and slow components in the initial-OSL signal (first 0.8 s or so) can give rise to erroneous dose estimates. Thus it is desirable to develop a dose estimation method that is based on the OSL from t...

  14. Fiber optic based OSL set up for online and offline measurements of dose due to ionizing radiation

    International Nuclear Information System (INIS)

    Rawat, N.S.; Kulkarni, M.S.; Upadhyay, B.N.; Srikanth, G.; Bindra, K.S.; Oak, S.M.

    2016-01-01

    An optic-fiber dosimetry system based on optically stimulated luminescence (OSL) and radio-luminescence (RL) from Al_2O_3 : C single-crystal (detector) was designed and developed. The set up is intended to measure dose and dose rates at various radiological installations. The Al_2O_3:C single crystal (from Landaeur Inc. USA) was coupled to a fiber optic delivery system and OSL from the detector is stimulated via the optical fiber cable using light from a Nd:YAG laser. OSL and RL signals are later used to predict cumulative dose and dose rates using "6"0Co gamma source. (author)

  15. Attaining provenance proxies from OSL and TL sensitivities: Coupling with grain size and heavy minerals data from southern Brazilian coastal sediments

    International Nuclear Information System (INIS)

    Zular, André; Sawakuchi, André O.; Guedes, Carlos C.F.; Giannini, Paulo C.F.

    2015-01-01

    In the São Francisco do Sul (SFS) barrier in southern Brazil, the optically stimulated luminescence (OSL) and thermoluminescence (TL) sensitivities of coastal sands vary according to geomorphological units. Sands from older beach ridges (ages older than 2000 years ago) show higher OSL and TL sensitivities than younger units (ages younger than 2000 years). Geomorphological units in the SFS attest to changes in provenance as a result of a coastal climate shift evidenced through grain size and heavy mineral analysis. We argue that in the SFS barrier sands, OSL and TL sensitivity signals provide an additional proxy to climate events and can be used as an alternative method to assess changes in provenance and tracking source-to-sink systems to monitor past and future environmental changes. - Highlights: • OSL and TL sensitivities are confronted with grain size and heavy minerals data. • We report OSL and 110 °C TL sensitivities as provenance proxies. • 110 °C TL sensitivity outlines environmental changes better than OSL sensitivity data.

  16. Study of morphological and luminescent properties (TL and OSL) of ZnO nanocrystals synthetized by coprecipitation method

    Energy Technology Data Exchange (ETDEWEB)

    Soares, A.F., E-mail: alvarodefarias@hotmail.com; Tatumi, S.H., E-mail: sonia.tatumi@gmail.com; Mazzo, T.M.; Rocca, R.R.; Courrol, L.C.

    2017-06-15

    In this work, ZnO nanocrystalline phosphorus were synthesized using the method of coprecipitation, subsequently different heat treatments at 900 and 1000 °C for 2 h and 1000 °C for 4 h were performed. Afterward, Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) emissions were verified after exposure to β-radiation. Photoluminescence results showed UV and VIS emissions. Morphological studies with X-ray diffraction (XRD) and Scanning Electron Microscopy (SEM) confirmed the crystallinity of the samples, with their well-shaped wurtzite hexagonal structures in nanoscale. ZnO calcinated at 900 °C – 2 h emitted a broad TL peak located between the 362–372 °C; for ZnO calcinated at 1000 °C – 2 h, two intense peaks were observed at 144 and 308 °C, this TL emission curve was investigated with more details using Computerized Glow Curve Deconvolution and six individual TL peaks were obtained, for sample irradiated with 40.6 Gy, corroborating with the T{sub m}-T{sub stop} results. A study of Minimum Detectable Dose (MDD) was made and a dose of (492±40) μGy was determined. CW-OSL and LM-OSL analysis were made for ZnO calcinated at 1000 °C – 2 h, allowed to verify the behaviour, and the curve existing components (fast and medium, depending on dose). As well as the calculation of the Minimum Detectable Dose for CW-OSL. - Highlights: •ZnO nanocrystals were successfully produced by the method of coprecipitation. •Grains sizes by Scherrer Equation were between 26.9–40.6 nm, corroborating with SEM. •Study of the TL emission: Computerized Glow Curve Deconvolution (CGCD) and Tm-Tstop. •TL emission of ZnO calcinated supplied the minimum detectable dose of (492±40) μGy. •Study of CW-OSL and LM-OSL with CGCD. MDD for CW-OSL evaluation of ZnO calcinated.

  17. A new luminescence detection and stimulation head for the Risø TL/OSL reader

    International Nuclear Information System (INIS)

    Lapp, T.; Kook, M.; Murray, A.S.; Thomsen, K.J.; Buylaert, J.-P.; Jain, M.

    2015-01-01

    A new automated Detection And Stimulation Head (DASH) has been developed for the Risø TL/OSL luminescence reader to provide easy access to new technologies, new signals and new measurement methods. The automated DASH includes a filter changer and a detector changer that makes it possible to change stimulation filters (4 × 4 filter combinations possible) and detectors (3 detectors possible) as part of a measurements sequence. The new automated DASH with dedicated driver electronics does not affect the use of other attachments, and can be retrospectively fitted to existing Risø TL/OSL readers. - Highlights: • A new detection and stimulation head for the Risø TL/OSL reader is described. • An example of the use of the filter changer is presented. • The power and spatial uniformity of blue, green and IR stimulation are characterised. • The potential of an EMCCD camera detector is described.

  18. Optically stimulated luminescence (OSL) from Ag-doped Li{sub 2}B{sub 4}O{sub 7} crystals

    Energy Technology Data Exchange (ETDEWEB)

    Kananen, B.E.; Maniego, E.S.; Golden, E.M.; Giles, N.C.; McClory, J.W. [Department of Engineering Physics, Air Force Institute of Technology, Wright-Patterson Air Force Base, OH 45433 (United States); Adamiv, V.T.; Burak, Ya.V. [Vlokh Institute of Physical Optics, Dragomanov 23, L’viv 79005 (Ukraine); Halliburton, L.E., E-mail: Larry.Halliburton@mail.wvu.edu [Department of Physics and Astronomy, West Virginia University, Morgantown, WV 26506 (United States)

    2016-09-15

    Optically stimulated luminescence (CW-OSL) is observed from Ag-doped lithium tetraborate (Li{sub 2}B{sub 4}O{sub 7}) crystals. Photoluminescence, optical absorption, and electron paramagnetic resonance (EPR) are used to identify the defects participating in the OSL process. As-grown crystals have Ag{sup +} ions substituting for Li{sup +} ions. They also have Ag{sup +} ions occupying interstitial sites. During a room-temperature exposure to ionizing radiation, holes are trapped at the Ag{sup +} ions that replace Li{sup +} ions and electrons are trapped at the interstitial Ag{sup +} ions, i.e., the radiation forms Ag{sup 2+} (4d{sup 9}) ions and Ag{sup 0} (4d{sup 10}5s{sup 1}) atoms. These Ag{sup 2+} and Ag{sup 0} centers have characteristic EPR spectra. The Ag{sup 0} centers also have a broad optical absorption band peaking near 370 nm. An OSL response is observed when the stimulation wavelength overlaps this absorption band. Specifically, stimulation with 400 nm light produces an intense OSL response when emission is monitored near 270 nm. Electrons optically released from the Ag{sup 0} centers recombine with holes trapped at Ag{sup 2+} ions to produce the ultraviolet emission. The OSL response is progressively smaller as the stimulation light is moved to longer wavelengths (i.e., away from the 370 nm peak of the absorption band of the Ag{sup 0} electron traps). Oxygen vacancies are also present in the Ag-doped Li{sub 2}B{sub 4}O{sub 7} crystals, and their role in the OSL process as a secondary relatively short-lived electron trap is described.

  19. Does deposition depth control the OSL bleaching of fluvial sediment?

    NARCIS (Netherlands)

    Cunningham, A. C.; Wallinga, J.; Hobo, N.; Versendaal, A. J.; Makaske, B.; Middelkoop, H.

    2014-01-01

    The Optically Stimulated Luminescence (OSL) signal from fluvial sediment often contains a remnant from the previous deposition cycle, leading to a partially bleached equivalent-dose distribution. Although identification of the burial dose is of primary concern, the degree of bleaching could

  20. Temperature dependence of OSL decay curves: Experimental and theoretical aspects

    DEFF Research Database (Denmark)

    McKeever, S.W.S.; Bøtter-Jensen, L.; Agersnap Larsen, N.

    1997-01-01

    ; (2) thermally assisted optical stimulation; (3) thermal quenching; and (4) localized donor-acceptor type recombination. Experimental OSL data from natural quartz and feldspars, stimulated with both green and infra-red light, are examined in the light of the theoretical considerations. (C) 1997...

  1. Correlation between TL and OSL signals in KMgF3:Ce3+: Bleaching study of individual glow-peaks

    International Nuclear Information System (INIS)

    Dallas, G.I.; Polymeris, G.S.; Afouxenidis, D.; Tsirliganis, N.C.; Tsagas, N.F.; Kitis, G.

    2010-01-01

    KMgF 3 :Ce 3+ is an ultra sensitive Thermoluminescence (TL) material with a complex TL and OSL glow-curve structure. The aim of the present work is to attempt a one-to-one correspondence between specific TL glow-peaks and OSL components in KMgF 3 :Ce 3+ . The correlation study involves the deconvolution of the TL curves and the estimation of the bleaching decay constants for individual glow-peaks followed by the deconvolution of the LM-OSL curve using the estimated decay constants. It was found that the bleaching of each individual glow-peak takes place in three different rates; namely in a fast, medium and slow rate.

  2. Angular dependence of the nanoDot OSL dosimeter

    OpenAIRE

    Kerns, James R.; Kry, Stephen F.; Sahoo, Narayan; Followill, David S.; Ibbott, Geoffrey S.

    2011-01-01

    Purpose: Optically stimulated luminescent detectors (OSLDs) are quickly gaining popularity as passive dosimeters, with applications in medicine for linac output calibration verification, brachytherapy source verification, treatment plan quality assurance, and clinical dose measurements. With such wide applications, these dosimeters must be characterized for numerous factors affecting their response. The most abundant commercial OSLD is the InLight∕OSL system from Landauer, Inc. The purpose of...

  3. Passive dosimetry: introduction of a new dosimeter based on OSL technology

    International Nuclear Information System (INIS)

    Archambault, V.; Le Roy, G.; Prugnaud, B.

    2005-01-01

    A new passive dosimeter based on OSL technology has been introduced on the French market. In this article are described: the technology and the material on which this new detector relied, the dosimeter itself. (author)

  4. Improvement of the M/S manipulator maintenance at OSL

    International Nuclear Information System (INIS)

    Kuwana, Koichi; Ouchi, Hiroshi; Ito, Yutaka; Sato, Yoshihiro; Midorikawa, Mituhiro; Hayakawa, Tuyoshi

    2010-01-01

    The safeguards inspection samples from the JNFL Rokkasho Reprocessing Plant (RRP) are received and analyzed at the On Site Laboratory (OSL). Since the samples from the input accountancy tank of the RRP contain a lot of fission products, they are treated in a hot-cell line with a M/S (Master /Slave) manipulator. Special equipment and tools were used for the maintenance of the M/S manipulator, especially for the exchange of the M/S manipulator. However, the manipulator exchange work was not easy due to the limitation of the space in the OSL. For solution to this problem, a monorail and monorail hoist equipment was installed onto wall surface of analytical room close to each M/S manipulator, and then it made the exchange of M/S manipulator easy without special equipment and tools. Additionally, operator was freed from the burden of working space arranging for the exchange of M/S manipulator such as removing of analytical equipments. This report represents the improvement of operation for the exchange of M/S manipulator with installation of monorail and hoist equipment. (author)

  5. LM-OSL from single grains of quartz: A preliminary study

    DEFF Research Database (Denmark)

    Bulur, E.; Duller, G.A.T.; Solongo, S.

    2002-01-01

    the easy-to-bleach component, those with only the hard-to-bleach component, and those exhibiting all components. The results of this preliminary study show that LM-OSL experiments carried out at the single grain level may give important insights into the luminescence properties observed when viewing...

  6. Characterization of an optically stimulated luminescence (OSL) material for thermal neutron detection: SrS:Ce,Sm,B

    International Nuclear Information System (INIS)

    Ravotti, Federico; Garcia, Pierre; Prevost, Hildegarde; Dusseau, Laurent; Lapraz, Dominique; Vaille, Jean-Roch; Benoit, David

    2008-01-01

    SrS:Ce,Sm exhibits some interesting phosphorescent and charge storage properties that are used in OSL (optically stimulated luminescence) radiation dosimetry. To enhance the thermal neutron sensitivity of this phosphor, a new material obtained by boron doping has been developed. This OSL, B material was analysed with respect to its optical and structural characteristics in order to study possible modifications induced by doping procedure. Optical study highlights a decrease in the material luminescence of about 40% with TL and OSL experiments. The emission spectrum remains the same after boron addition. This result is in agreement with the structural characterization analysis since the lattice parameters were not modified. 11B MAS NMR results indicate that boron atoms are present in the host lattice in form of BO4 groups. Consequences on dosimetry applications are discussed. The neutron response of the OSL, B irradiated in a nuclear reactor is linear up to a fluence of 5 x 1011 cm -2 and it is possible to separate the thermal neutron and gamma components. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  7. Optically stimulated luminescence (OSL) dating of shallow marine sediments to develop an analysis method of late Quaternary geodynamics

    International Nuclear Information System (INIS)

    Hataya, Ryuta; Shirai, Masaaki

    2003-01-01

    To develop an analysis method of geodynamics, we have examined the applicability of the OSL dating of marine terrace deposits. We have done the OSL dating, using the multiple-aliquot additive-dose technique, of shallow marine sediments from the upper part the Kioroshi Formation in Ibaraki Prefecture, which are correlated to Marine Oxygen Isotope Stage (MIS) 5e-5c. Marine terrace deposit consists mainly of shallow marine sediment. OSL ages of foreshore and foreshore-shoreface beds are 88-112 Ka, and are in good agreement with the geological/geomorphological data. On the other hand, OSL ages of the backshore bed are younger, and ones of the shoreface bed are older than geologically estimated ages. These results show that OPSL dating method can date shallow marine sediment using samples from foreshore and foreshore-shoreface beds, and that this method can distinguish terrace deposits formed in MIS5 and that in MIS7 by taking geomorphologic information into account. These results contribute to the characterization of long-term geological movement in coastal areas. (author)

  8. SSDL Preparation for Implementation of the Use of OSL Dosimeters in Malaysia

    International Nuclear Information System (INIS)

    Sangau, J.K.; Taiman Kadni; Ahmad Bazlie Abdul Kadir

    2013-01-01

    Since the early 1980's, film badge has been widely used as a device of personal dose monitoring in Malaysia. Secondary Standard Dosimetry Laboratory (SSDL), as a service center for film badge has obtained the supply of personal monitoring film from Agfa Gevaert, Belgium every year. As the uses of film badge have some weaknesses, it has prompted SSDL to find an alternative dosimeter to replace the film badge. Based on the studies that have been conducted, SSDL has selected OSL dosimeter (Optically Stimulated Luminescent Dosimeter) to replace the film badge and is expected to be fully operational by middle of 2015. This paper aims to explain the selection of OSL dosimeter and planning carried out to ensure the success of their application in Malaysia. (author)

  9. The TL and room temperature OSL properties of the glow peak at 110 deg. C in natural milky quartz: A case study

    International Nuclear Information System (INIS)

    Polymeris, George S.; Afouxenidis, Dimitrios; Tsirliganis, Nestor C.; Kitis, George

    2009-01-01

    The LM-OSL signal of quartz, while measured at room temperature, is dominated by an intermediate, broad and intense OSL component, so that its contribution and general characteristics are derived very accurately. Through a series of dose-response, bleaching and thermal decay at room temperature experiments, in conjunction with curve fitting studies, a component resolved analysis is carried out studying the correlation between this specific component, termed as LM-OSL component C 2 and the 110 deg. C TL glow peak in quartz. The dose-response of these two luminescence components behaves exactly similar being linear at low doses and saturating at almost 100 Gy. Both signals decay exponentially under illumination, providing identical optical detrapping cross-section values. Residual of both luminescence signals after thermal decay at room temperature follows an exponential law, yielding similar mean half-lives. All previous luminescence features provide strong evidence for the electron trap being the same for both the 110 deg. C TL trap and the LM-OSL component C 2 . The results of the present work are very promising and clearly support the possibility of extrapolating the TL pre-dose methodology to the OSL pre-dose effect using only the LM-OSL component C 2

  10. Dependence of the anomalous fading of the TL and blue-OSL of fluorapatite on the occupancy of the tunnelling recombination sites

    International Nuclear Information System (INIS)

    Tsirliganis, N.C.; Polymeris, G.S.; Kitis, G.; Pagonis, V.

    2007-01-01

    The anomalous fading (AF) of thermoluminescence (TL) and optically stimulated luminescence (OSL) signals in Durango apatite is attributed to tunnelling effects. Electrons from the TL and OSL traps in this material are transferred, via a tunnelling effect, to the recombination sites. The availability of recombination sites for tunnelled electrons is of major importance for the degree of AF rate observed in this material. It is expected that a variation of the number of the electron recombination sites will be reflected in the experimentally measured AF rate. In the present work an investigation of the recombination sites for the tunnelled electrons is attempted by studying the AF effect using a special technique, in which the anomalously faded TL (OSL) is replaced by an equal amount of TL (OSL) induced by a beta dose

  11. Persistent luminescence, TL and OSL characterization of beta irradiated SrAl2O4:Eu2+, Dy3+ combustion synthesized phosphor

    International Nuclear Information System (INIS)

    Zúñiga-Rivera, N.J.; García, R.; Rodríguez-Mijangos, R.; Chernov, V.; Meléndrez, R.; Pedroza-Montero, M.; Barboza-Flores, M.

    2014-01-01

    The persistent luminescence (PLUM), thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of strontium aluminates co-doped with Eu +2 and Dy +3 exposed to beta radiation is reported. The phosphor was synthesized by the combustion synthesis method employing a highly exothermic redox reaction between the metal nitrates [Al(NO 3 ) 3 , Sr(NO 3 ) 2 , Eu(NO 3 ) 3 and Dy(NO 3 ) 3 ] and organic fuel carbohydrazide (CH 6 N 4 O). The long decay PLUM emission, TL and OSL were measured as a function of beta radiation dose. A wide emission band centered at 510 nm (green) related to Eu 2+ ions and lattice defects were observed for the synthesized samples. The presence of a variety of defects and aggregates were responsible for the observed broad 100 °C peaked TL glow curve of the irradiated sample which is composed of several overlapped TL peaks. The existence of multiple trapping levels, with different trapping/detrapping probabilities, is behind the particular features for the PLUM, TL and OSL emissions. We conclude that in the SrAl 2 O 4 :Eu 2+ , Dy 3+ phosphors, the low temperature TL peaked around 30–75 °C is responsible for the PLUM emission and those around 100 °C were related to very stable trapping states which provide suitable radiation storage properties to be used as a PLUM/TL/OSL radiation phosphor

  12. Retrospective dosimetry using Japanese brick quartz: A way forward despite an unstable fast decaying OSL signal

    DEFF Research Database (Denmark)

    Fujita, Hiroki; Jain, Mayank; Murray, A.S.

    2011-01-01

    signals has been carried out towards identification of common source traps. It is observed that OSL from Japanese brick quartz shows unusual luminescence characteristics; in particular, the initial fast decaying OSL signal contains a dominant (>90%) thermally unstable component related to the 85 °C TL...... peak, which necessitates a prior heat treatment. A single-aliquot regenerative-dose (SAR) protocol is developed and tested using thermal treatments intended to isolate a stable dosimetric signal. A minimum detection limit of 65 mGy is then estimated using this protocol. Following irradiation using 60Co...... of Japanese brick quartz examined here can be used to derive precise estimates of accident dose, and, possibly to distinguish between sources of gamma radiation in a nuclear accident. To our knowledge, this is the first report on the existence of an unstable fast decaying OSL signal in quartz derived from...

  13. Optimization of CW-OSL parameters for improved dose detection threshold in Al2O3:C

    International Nuclear Information System (INIS)

    Rawat, N.S.; Dhabekar, B.; Kulkarni, M.S.; Muthe, K.P.; Mishra, D.R.; Soni, A.; Gupta, S.K.; Babu, D.A.R.

    2014-01-01

    Continuous wave optically stimulated luminescence (CW-OSL) is relatively a simple technique that offers good signal to noise ratio (SNR) and involves simple instrumentation. This study reports the influence and optimization of CW-OSL parameters on minimum detectable dose (MDD) using α-Al 2 O 3 :C phosphor. It is found that at a given stimulation intensity MDD in CW-OSL mode depends on signal integration time. At lower integration times MDD is inferior. It exhibits an improvement for intermediate values, shows a plateau region and deteriorates as integration time increases further. MDD is found to be ∼127 μGy at 4 mW/cm 2 stimulation intensity for integration time of 0.1 s, which improves to ∼10.5 μGy for 60 s. At stimulation intensity of 72 mW/cm 2 , MDD is 37 μGy for integration time of 60 s and improves significantly to 7 μGy for 1 s. - Highlights: • CW-OSL parameters are optimized to obtain best SNR and MDD in Al 2 O 3 :C. • MDD is found to depend on signal integration time and stimulation intensity. • With time, MDD initially improves, stabilizes then deteriorates. • At a given intensity, MDD is optimum for a certain range of integration time

  14. An application of artificial neural intelligence for personal dose assessment using a multi-area OSL dosimetry system

    International Nuclear Information System (INIS)

    Lee, S.-Y.Sang-Yoon.; Kim, B.-H.Bong-Hwan; Lee, K.J.Kun Jai

    2001-01-01

    Significant advances have been made in recent years to improve measurement technology and performance of phosphor materials in the fields of optically stimulated luminescence (OSL) dosimetry. Pulsed and continuous wave OSL studies recently carried out on α-Al 2 O 3 : C have shown that the material seems to be the most promising for routine application of OSL for dosimetric purposes. The main objective of the study is to propose a new personal dosimetry system using α-Al 2 O 3 : C by taking advantage of its optical properties and energy dependencies. In the process of the study, a new dose assessment algorithm was developed using artificial neural networks in hopes of achieving a higher degree of accuracy and precision in personal OSL dosimetry system. The original hypothesis of this work is that the spectral information of an X- and γ-ray fields may be obtained by the analysis of the response of a multi-element system. In this study, a feedforward neural network using the error back-propagation method with Bayesian optimization was applied for the response unfolding procedure. The validation of the proposed algorithm was investigated by unfolding the 10 measured responses of α-Al 2 O 3 : C for arbitrarily mixed photon fields which range from 20 to 662 keV

  15. TL and OSL properties of Mn2+-doped MgGa2O4 phosphor

    Science.gov (United States)

    Luchechko, A.; Zhydachevskyy, Ya; Maraba, D.; Bulur, E.; Ubizskii, S.; Kravets, O.

    2018-04-01

    The oxide MgGa2O4 spinel ceramics doped with Mn2+ ions was synthesized by a solid-state reaction at 1200 °C in air. The activator concentration was equal 0.05 mol% of MnO. Phase purity of the synthesized samples was analyzed by X-ray diffraction technique. This spinel ceramics show efficient green emission in the range from 470 to 550 nm with a maximum at about 505 nm under UV or X-ray excitations, which is due to Mn2+ ions. MgGa2O4: Mn2+ exhibits intense thermoluminescence (TL) and optically stimulated luminescence (OSL) after influence of ionizing radiation. Are complex nature of the TL glow curves is associated with a significant number of structural defects that are responsible for the formation of shallow and deep electron traps. In this work, time-resolved OSL characteristics of the samples exposed to beta particles are reported for the first time. A light from green LED was used for optical stimulation. Obtained TL and OSL results suggest MgGa2O4:Mn2+ as perspective material for further research and possible application in radiation dosimetry.

  16. Analysis of optical bleaching of OSL signal in sediment quartz

    International Nuclear Information System (INIS)

    Przegiętka, K.R.; Chruścińska, A.

    2013-01-01

    The aim of this work was to study the effect of the quality of optical bleaching on the results of OSL (Optically Stimulated Luminescence) dating method. The large aliquots of coarse quartz grains extracted from fluvial deposit were used in the study. The poor, medium and good bleaching were simulated in laboratory with help of Blue LED light source in series of experiments. Then the samples were irradiated with a common laboratory dose. The equivalent doses (DE) were measured by the help of standard Single Aliquot Regeneration (SAR) technique, but obtained DE distributions are analyzed in a new way. The method for recognizing and compensating for partial bleaching is proposed. The conclusions for dating sediment quartz samples are presented and discussed. -- Highlights: ► Bleaching experiments on sediment quartz are performed. ► Blue LED light source incorporated in luminescence reader is used. ► New analysis of data measured by standard SAR OSL technique is proposed. ► The results are promising for recognizing and compensating for partial bleaching

  17. OSL and TL of Resistors of Mobile Phones for Retrospective Accident Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. I.; Kim, J. L.; Pradhan, A. S.; Chang, I.; Kim, B. H. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    work place and in the public rather than actual health hazard due to radiation exposure. Therefore, a quick demonstration of measurement of doses following the accident is needed to reassure those receiving insignificant or low level of exposures that they are quite safe and need no treatment. This confidence building also becomes an important aspect of dosimetry. As the ranges of doses which could be encountered in such situations may vary from the background level to significantly high doses depending on the type of accident / incident and the location of personnel, it becomes important that the techniques used in retrospective dosimetry should be very sensitive and should be able to measure doses in a wide range from background level to several Gy. More recently, with the increasing apprehensions of nuclear terrorism / dirty bomb, research and developments in retrospective dosimetry has gained a new momentum the world over. Among the TL and OSL sensitive materials, the extraction and the processing of the materials from bricks and roof tiles is a very time consuming process and gives indirect estimate of individual doses. On the other hand, TL and OSL properties of components of electronic devices mobile phones, i-pods, black-berries, mp3 players and USB sticks containing ceramics with luminescence properties (e.g resistors, capacitors, resonators, antenna switches, transistors etc.) and chip cards containing silica epoxy (e.g. credit cards, bank cards, social security card, telephone card, SIM cards, ID cards e.g) are being considered very attractive and being evaluated. In this study, the TL and OSL properties of the electronic components of mobile phones are investigated and dose recovery potential is evaluated with a presumption that a mobile phone has become a part of body belongings masses of almost ages

  18. OSL and TL of Resistors of Mobile Phones for Retrospective Accident Dosimetry

    International Nuclear Information System (INIS)

    Lee, J. I.; Kim, J. L.; Pradhan, A. S.; Chang, I.; Kim, B. H.

    2012-01-01

    and in the public rather than actual health hazard due to radiation exposure. Therefore, a quick demonstration of measurement of doses following the accident is needed to reassure those receiving insignificant or low level of exposures that they are quite safe and need no treatment. This confidence building also becomes an important aspect of dosimetry. As the ranges of doses which could be encountered in such situations may vary from the background level to significantly high doses depending on the type of accident / incident and the location of personnel, it becomes important that the techniques used in retrospective dosimetry should be very sensitive and should be able to measure doses in a wide range from background level to several Gy. More recently, with the increasing apprehensions of nuclear terrorism / dirty bomb, research and developments in retrospective dosimetry has gained a new momentum the world over. Among the TL and OSL sensitive materials, the extraction and the processing of the materials from bricks and roof tiles is a very time consuming process and gives indirect estimate of individual doses. On the other hand, TL and OSL properties of components of electronic devices mobile phones, i-pods, black-berries, mp3 players and USB sticks containing ceramics with luminescence properties (e.g resistors, capacitors, resonators, antenna switches, transistors etc.) and chip cards containing silica epoxy (e.g. credit cards, bank cards, social security card, telephone card, SIM cards, ID cards e.g) are being considered very attractive and being evaluated. In this study, the TL and OSL properties of the electronic components of mobile phones are investigated and dose recovery potential is evaluated with a presumption that a mobile phone has become a part of body belongings masses of almost ages

  19. Rapid and cyclic dust accumulation during MIS 2 in Central Asia inferred from loess OSL dating and grain-size analysis.

    Science.gov (United States)

    Li, Yun; Song, Yougui; Lai, Zhongping; Han, Li; An, Zhisheng

    2016-09-02

    Due to lack of reliable proxies from the Westerlies-dominant region, the strength change of Northern Hemisphere Westerlies remains poorly understood. The aim of this study is to provide a reliable paleoclimatic proxy about the Northern Hemisphere Westerlies change. Here we report a 30.7 m thick loess section from the Ili basin directly controlled by the Westerlies. Based on optically stimulated luminescence (OSL) and high resolution grain-size records, we reconstruct the change history of the Westerlies strength during the last glacial period (mainly Marine Isotope Stages 2, MIS2), being similar with the Westerlies index recorded in the Qinghai Lake sediments. Within error limits, all ages are in stratigraphic order. We further compare the climatic records among the Ili loess, Qinghai Lake and the NGRIP, their similarity shows a good climatic coupling relationship among the Central Asia, East Asia and the North Atlantic, and the Westerlies plays a critical influence in transporting the North Atlantic signal to Central and East Asia.

  20. Optically stimulated luminescence (OSL) as a chronometer for surface exposure dating

    DEFF Research Database (Denmark)

    Sohbati, Reza; Murray, Andrew S.; Chapot, Melissa S.

    2012-01-01

    We pioneer a technique of surface-exposure dating based upon the characteristic form of an optically stimulated luminescence (OSL) bleaching profile beneath a rock surface; this evolves as a function of depth and time. As a field illustration of this new method, the maximum age of a premier example...... exposure histories; one of these samples was exposed at the time of sampling and one was buried and no longer light exposed. A third sample is known to have been first exposed 80 years ago and was still exposed at the time of sampling. First, the OSL-depth profile of the known-age sample is modeled...... to estimate material-dependent and environmental parameters. These parameters are then used to fit the model to the corresponding data for the samples of unknown exposure history. From these fits we calculate that the buried sample was light exposed for similar to 700 years before burial and that the unburied...

  1. New data on OSL dating of Early Khalynian deposits of Northern Caspian

    Science.gov (United States)

    Sychev, Nikita; Yanina, Tamara; Svitoch, Alexander; Kurbanov, Redzhep; Badyukova, Ekaterina

    2016-04-01

    regressions) reaches high values (Arslanov, 2015). Therefore in this paper we describe the new OSL-dating results of Khalynian transgression sediments. Two key sections were selected for study: Srednaya Akhtuba and Nizhneye Zaymische. The first section - Srednaya Akhtuba is located in the slope of the ravine, cutting through the marine plain, 1 km above the bridge across the Akhtuba river. Nizhneye Zaymische located in the slope of Volga-Akhtuba valley, cutting through the marine Khalynian plain. For the dating of these deposits we used Risø OSL-reader (provided by Nordic luminescence Lab and DTU), and standard SAR protocol (Murray, 2004). The obtained results characterize 5 equivalent doses of chocolate clays samples. The first date was obtained for the top of the chocolate clay, one for the bottom. Accordingly, two calculated OSL-dates indicate the age of these deposits corresponding to initial stage of the first marine isotope stage (MIS-1). These dates are well correlated with the characteristics of age, obtained by radiocarbon and U-Th methods that show their high reliability. The equivalent dose obtained for chocolate clays of Nizhneye Zaimishce is 43 Gy, radiation dose in Akhtuba sediments was about 3.1 Gy per thousand years. This research was supported by the Russian Science Foundation Project 14-17-00705.

  2. High-resolution X-ray television and high-resolution video recorders

    International Nuclear Information System (INIS)

    Haendle, J.; Horbaschek, H.; Alexandrescu, M.

    1977-01-01

    The improved transmission properties of the high-resolution X-ray television chain described here make it possible to transmit more information per television image. The resolution in the fluoroscopic image, which is visually determined, depends on the dose rate and the inertia of the television pick-up tube. This connection is discussed. In the last few years, video recorders have been increasingly used in X-ray diagnostics. The video recorder is a further quality-limiting element in X-ray television. The development of function patterns of high-resolution magnetic video recorders shows that this quality drop may be largely overcome. The influence of electrical band width and number of lines on the resolution in the X-ray television image stored is explained in more detail. (orig.) [de

  3. Single-grain quartz OSL dating of debris flow deposits from Men Tou Gou, south west Beijing, China

    DEFF Research Database (Denmark)

    Zhao, Qiuyue; Thomsen, Kristina Jørkov; Murray, A. S.

    2017-01-01

    of the return frequency of these debris flows, risk assessment and climate change research. In this project, we use quartz single-grain optically stimulated luminescence (OSL) methods to determine the burial ages of five debris flow samples from the Zhai Tang region -60 km west of Beijing. OSL characteristics...... poorly bleached prior to deposition; relative over-dispersions are larger than 60%. Minimum age modelling indicates that all five samples were deposited within the past few hundred years, indicating that catastrophic debris flows are occurring under the historically-recent land-use pattern....

  4. A method to acquire CT organ dose map using OSL dosimeters and ATOM anthropomorphic phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Da; Li, Xinhua; Liu, Bob [Division of Diagnostic Imaging Physics and Webster Center for Advanced Research and Education in Radiation, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Gao, Yiming; Xu, X. George [Nuclear Engineering Program, Rensselaer Polytechnic Institute, Troy, New York 12180 (United States)

    2013-08-15

    Purpose: To present the design and procedure of an experimental method for acquiring densely sampled organ dose map for CT applications, based on optically stimulated luminescence (OSL) dosimeters “nanoDots” and standard ATOM anthropomorphic phantoms; and to provide the results of applying the method—a dose data set with good statistics for the comparison with Monte Carlo simulation result in the future.Methods: A standard ATOM phantom has densely located holes (in 3 × 3 cm or 1.5 × 1.5 cm grids), which are too small (5 mm in diameter) to host many types of dosimeters, including the nanoDots. The authors modified the conventional way in which nanoDots are used, by removing the OSL disks from the holders before inserting them inside a standard ATOM phantom for dose measurements. The authors solved three technical difficulties introduced by this modification: (1) energy dependent dose calibration for raw OSL readings; (2) influence of the brief background exposure of OSL disks to dimmed room light; (3) correct pairing between the dose readings and measurement locations. The authors acquired 100 dose measurements at various positions in the phantom, which was scanned using a clinical chest protocol with both angular and z-axis tube current modulations.Results: Dose calibration was performed according to the beam qualities inside the phantom as determined from an established Monte Carlo model of the scanner. The influence of the brief exposure to dimmed room light was evaluated and deemed negligible. Pairing between the OSL readings and measurement locations was ensured by the experimental design. The organ doses measured for a routine adult chest scan protocol ranged from 9.4 to 18.8 mGy, depending on the composition, location, and surrounding anatomy of the organs. The dose distribution across different slices of the phantom strongly depended on the z-axis mA modulation. In the same slice, doses to the soft tissues other than the spinal cord demonstrated

  5. A method to acquire CT organ dose map using OSL dosimeters and ATOM anthropomorphic phantoms

    International Nuclear Information System (INIS)

    Zhang, Da; Li, Xinhua; Liu, Bob; Gao, Yiming; Xu, X. George

    2013-01-01

    Purpose: To present the design and procedure of an experimental method for acquiring densely sampled organ dose map for CT applications, based on optically stimulated luminescence (OSL) dosimeters “nanoDots” and standard ATOM anthropomorphic phantoms; and to provide the results of applying the method—a dose data set with good statistics for the comparison with Monte Carlo simulation result in the future.Methods: A standard ATOM phantom has densely located holes (in 3 × 3 cm or 1.5 × 1.5 cm grids), which are too small (5 mm in diameter) to host many types of dosimeters, including the nanoDots. The authors modified the conventional way in which nanoDots are used, by removing the OSL disks from the holders before inserting them inside a standard ATOM phantom for dose measurements. The authors solved three technical difficulties introduced by this modification: (1) energy dependent dose calibration for raw OSL readings; (2) influence of the brief background exposure of OSL disks to dimmed room light; (3) correct pairing between the dose readings and measurement locations. The authors acquired 100 dose measurements at various positions in the phantom, which was scanned using a clinical chest protocol with both angular and z-axis tube current modulations.Results: Dose calibration was performed according to the beam qualities inside the phantom as determined from an established Monte Carlo model of the scanner. The influence of the brief exposure to dimmed room light was evaluated and deemed negligible. Pairing between the OSL readings and measurement locations was ensured by the experimental design. The organ doses measured for a routine adult chest scan protocol ranged from 9.4 to 18.8 mGy, depending on the composition, location, and surrounding anatomy of the organs. The dose distribution across different slices of the phantom strongly depended on the z-axis mA modulation. In the same slice, doses to the soft tissues other than the spinal cord demonstrated

  6. Two-dimensional chronostratigraphic modelling of OSL ages from recent beach-ridge deposits, SE Australia

    DEFF Research Database (Denmark)

    Tamura, Toru; Cunningham, Alastair C.; Oliver, Thomas S.N.

    2018-01-01

    Optically-stimulated luminesecne (OSL) dating, in concert with two-dimensional ground-penetrating radar (GPR) profiling, has contributed to significant advances in our understanding of beach-ridge systems and other sedimentary landforms in various settings. For recent beach-ridges, the good OSL...... samples may be larger than the difference in sample ages. Age inversions can be avoided, however, if the stratigraphic constraints are included in the age estimation process. Here, we create a custom Bayesian chronological model for a recent (..., for direct comparison with a GPR profile. The model includes a full ‘burial-dose model’ for each sample and a dose rate term with the modelled ages constrained by the vertical and shore-normal sample order. The modelled ages are visualized by plotting isochrones on the beach-ridge cross section...

  7. Constraining Middle Pleistocene Glaciations in Birmingham, England; Using Optical Stimulated Luminescence (OSL) Dating.

    Science.gov (United States)

    Gibson, S. M.; Gibbard, P. L.; Bateman, M. D.; Boreham, S.

    2014-12-01

    Birmingham is built on a complex sequence of Middle Pleistocene sediments, representing at least three lowland glaciations (MIS12, MIS6, and MIS2). British Geological Survey mapping accounts 75% of the land mass as Quaternary deposits; predominantly glacial-sandy tills, glacial-fluvial sands, clays and organic silts and peats. Understanding the age of fluvial-glacial outwash, related to specific glaciations, is critical in establishing a Geochronology of Birmingham. Shotton (1953) found a series of Middle Pleistocene glacial sediments, termed the Wolstonian, intermediate in age between MIS11 and MIS5e Interglacial's. Uncertainty surrounding the relation to East Anglian sequences developed by Rose (1987) implies Birmingham sequences should be referred to MIS12. Despite this, younger Middle Pleistocene glacial sequences occur in Birmingham, yet uncertainty has deepened over our understanding of the complex, inaccessible sediments, especially as deposits have similar extent with MIS2 sequences. Five Optical Stimulated Luminescence (OSL) dates from three sites around Birmingham have been sampled. East of Birmingham, ice advanced from the Irish Sea and later the North East. In Wolston, a sample of outwash sand, associated with the Thurssington Till, is dated. In Meriden, two samples of outwash sands, associated with a distal Oadby Till, are dated. West of Birmingham, ice advanced from the Welsh Ice Sheet. In Seisdon, two samples of an Esker and outwash sand, associated with a Ridgeacre Till, are dated. Correlation of OSL dates provide an important constraint on understanding the history of Birmingham. Using GSI3D modeling to correlate geochronology and sedimentology, the significance of OSL dating can be understood within the complex sequences (and regional stratigraphy), complimented by Cosmogenic and Palynology dates taken in South West and North East. OSL dating on Birmingham's outwash sands, deposited by extensive repeated Middle Pleistocene glaciations, asserts the

  8. Sources of uncertainties in OSL dating of archaeological mortars: The case study of the Roman amphitheatre “Palais-Gallien” in Bordeaux

    International Nuclear Information System (INIS)

    Urbanova, P.; Hourcade, D.; Ney, C.; Guibert, P.

    2015-01-01

    dispersive X-ray spectroscopy cartography, Beta-radiography imaging, inductively coupled plasma mass spectrometry) were employed to demonstrate the presence of this phenomenon. Despite the extremely large proportion of high equivalent doses in equivalent dose distributions, there is an apparent presence of well-bleached grains at the beginning of equivalent dose distributions. The study shows the potential of dating mortars by single grain OSL. - Highlights: • Fewer than 8% of all measured grains exhibited an OSL signal. • The heterogeneity of β-irradiation arises principally from variations of K-content. • Beta-imaging confirmed inhomogeneous distribution of beta sources in studied samples. • The samples are highly affected by heterogeneous bleaching. • Standard age models are not adapted for the studied series of samples

  9. Estimation of identification limit for a small-type OSL dosimeter on the medical images by measurement of X-ray spectra.

    Science.gov (United States)

    Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2016-07-01

    Our aim in this study is to derive an identification limit on a dosimeter for not disturbing a medical image when patients wear a small-type optically stimulated luminescence (OSL) dosimeter on their bodies during X-ray diagnostic imaging. For evaluation of the detection limit based on an analysis of X-ray spectra, we propose a new quantitative identification method. We performed experiments for which we used diagnostic X-ray equipment, a soft-tissue-equivalent phantom (1-20 cm), and a CdTe X-ray spectrometer assuming one pixel of the X-ray imaging detector. Then, with the following two experimental settings, corresponding X-ray spectra were measured with 40-120 kVp and 0.5-1000 mAs at a source-to-detector distance of 100 cm: (1) X-rays penetrating a soft-tissue-equivalent phantom with the OSL dosimeter attached directly on the phantom, and (2) X-rays penetrating only the soft-tissue-equivalent phantom. Next, the energy fluence and errors in the fluence were calculated from the spectra. When the energy fluence with errors concerning these two experimental conditions was estimated to be indistinctive, we defined the condition as the OSL dosimeter not being identified on the X-ray image. Based on our analysis, we determined the identification limit of the dosimeter. We then compared our results with those for the general irradiation conditions used in clinics. We found that the OSL dosimeter could not be identified under the irradiation conditions of abdominal and chest radiography, namely, one can apply the OSL dosimeter to measurement of the exposure dose in the irradiation field of X-rays without disturbing medical images.

  10. OSL and TL dosimeter characterization of boron doped CVD diamond films

    Science.gov (United States)

    Gonçalves, J. A. N.; Sandonato, G. M.; Meléndrez, R.; Chernov, V.; Pedroza-Montero, M.; De la Rosa, E.; Rodríguez, R. A.; Salas, P.; Barboza-Flores, M.

    2005-04-01

    Natural diamond is an exceptional prospect for clinical radiation dosimetry due to its tissue-equivalence properties and being chemically inert. The use of diamond in radiation dosimetry has been halted by the high market price; although recently the capability of growing high quality CVD diamond has renewed the interest in using diamond films as radiation dosimeters. In the present work we have characterized the dosimetric properties of diamond films synthesized by the HFCVD method. The thermoluminescence and the optically stimulated luminescence of beta exposed diamond sample containing a B/C 4000 ppm doping presents excellent properties suitable for dosimetric applications with β-ray doses up to 3.0 kGy. The observed OSL and TL performance is reasonable appropriate to justify further investigation of diamond films as dosimeters for ionizing radiation, specially in the radiotherapy field where very well localized and in vivo and real time radiation dose applications are essential.

  11. Quartz OSL dating of late Holocene beach ridges from the Magdalen Islands (Quebec, Canada)

    DEFF Research Database (Denmark)

    Remillard, A.M.; Buylaert, Jan-Pieter; Murray, Andrew

    2015-01-01

    Quartz optically stimulated luminescence (OSL) dating has been applied to sandy beach ridge systems from the Magdalen Islands in the center of the Gulf of St. Lawrence (Quebec, Canada) to provide the first chronological framework for these features. Nineteen beach ridges (22 samples) from four......). The OSL ages indicate that the ridges were built between 2.6 ± 0.2 ka and 0.40 ± 0.10 ka, i.e. during a period of sea level rise. This rise eroded adjacent sandstone cliffs, which contributed a significant sediment supply to the littoral drift and beaches. Some low-lying coasts in the archipelago...... great potential in this area, and is an appropriate method for establishing precise chronologies for coastal sediments in this region of the Gulf of St. Lawrence. © 2015 Elsevier B.V. All rights reserved....

  12. ANL high resolution injector

    International Nuclear Information System (INIS)

    Minehara, E.; Kutschera, W.; Hartog, P.D.; Billquist, P.

    1985-01-01

    The ANL (Argonne National Laboratory) high-resolution injector has been installed to obtain higher mass resolution and higher preacceleration, and to utilize effectively the full mass range of ATLAS (Argonne Tandem Linac Accelerator System). Preliminary results of the first beam test are reported briefly. The design and performance, in particular a high-mass-resolution magnet with aberration compensation, are discussed. 7 refs., 5 figs., 2 tabs

  13. Fake age hiatus in a loess section revealed by OSL dating of calcrete nodules

    Science.gov (United States)

    Zhang, Junjie; Li, Sheng-Hua; Sun, Jimin; Hao, Qingzhen

    2018-04-01

    Optically stimulated luminescence (OSL) dating on potassium feldspar has been performed with high resolution in the Luochuan section in the Chinese Loess Plateau. An age hiatus of ∼ 15 ka is found at the top of L2 layer within the loess/paleosol sequences. The age of the potassium feldspar from the calcrete nodules along the S1/L2 boundary is significantly older than those of the paleosol and loess samples lying above and below the boundary. The age overestimation of the potassium feldspar from calcrete nodules is caused by the underestimation of the dose rate, because accretion of carbonates could dilute the radioactivity. The age hiatus at the top of L2 also resulted from the underestimation of the dose rates of four loess samples beneath this hiatus. These four loess samples have high CaO concentrations. Ages of these samples are overestimated in the similar way as the nodules, but with smaller degrees. All results suggest that the accretion of carbonates happened after the loess deposition. The carbonate accretion process of the calcrete nodules has been simulated with accumulation models. The accretion can be as young as 46 ka, assuming the calcrete nodules formed rapidly at a certain time point. For slow and gradual accretion models, the carbonate started to accumulate slowly since the dust deposition and the accumulation became faster afterwards. The transition of the accretion rate may relate to the climate change or a change in the carbonate leaching and re-precipitation system.

  14. Persistent luminescence, TL and OSL characterization of beta irradiated SrAl{sub 2}O{sub 4}:Eu{sup 2+}, Dy{sup 3+} combustion synthesized phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Zúñiga-Rivera, N.J. [Departamento de Física, Posgrado en Nanotecnología, Universidad de Sonora, Hermosillo, Sonora 83000 (Mexico); García, R.; Rodríguez-Mijangos, R.; Chernov, V.; Meléndrez, R.; Pedroza-Montero, M. [Departamento de Investigación en Física, Universidad de Sonora, Hermosillo, Sonora 83000 (Mexico); Barboza-Flores, M., E-mail: mbarboza@cifus.uson.mx [Departamento de Investigación en Física, Universidad de Sonora, Hermosillo, Sonora 83000 (Mexico)

    2014-05-01

    The persistent luminescence (PLUM), thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of strontium aluminates co-doped with Eu{sup +2} and Dy{sup +3} exposed to beta radiation is reported. The phosphor was synthesized by the combustion synthesis method employing a highly exothermic redox reaction between the metal nitrates [Al(NO{sub 3}){sub 3}, Sr(NO{sub 3}){sub 2}, Eu(NO{sub 3}){sub 3} and Dy(NO{sub 3}){sub 3}] and organic fuel carbohydrazide (CH{sub 6}N{sub 4}O). The long decay PLUM emission, TL and OSL were measured as a function of beta radiation dose. A wide emission band centered at 510 nm (green) related to Eu{sup 2+} ions and lattice defects were observed for the synthesized samples. The presence of a variety of defects and aggregates were responsible for the observed broad 100 °C peaked TL glow curve of the irradiated sample which is composed of several overlapped TL peaks. The existence of multiple trapping levels, with different trapping/detrapping probabilities, is behind the particular features for the PLUM, TL and OSL emissions. We conclude that in the SrAl{sub 2}O{sub 4}:Eu{sup 2+}, Dy{sup 3+} phosphors, the low temperature TL peaked around 30–75 °C is responsible for the PLUM emission and those around 100 °C were related to very stable trapping states which provide suitable radiation storage properties to be used as a PLUM/TL/OSL radiation phosphor.

  15. TL/OSL ages from Salto Formation (Uruguay)tectonic, climatic and environmental considerations

    International Nuclear Information System (INIS)

    Ubilla, M.; Veroslavsky, G.

    2004-01-01

    TL/OSL ages from Salto Formation based on two sandy samples collected at Salto City and Route 3 (Boycua Creek) are provided: 986±100 ky (LVD-948) and 830±95 ky (LVD-949) respectively. Both support a Pleistocene age for Salto Formation, approximately late early/early middle Pleistocene. Neotectonic and climatic processes are also discussed [es

  16. OSL sensitivity changes during single aliquot procedures: Computer simulations

    DEFF Research Database (Denmark)

    McKeever, S.W.S.; Agersnap Larsen, N.; Bøtter-Jensen, L.

    1997-01-01

    We present computer simulations of sensitivity changes obtained during single aliquot, regeneration procedures. The simulations indicate that the sensitivity changes are the combined result of shallow trap and deep trap effects. Four separate processes have been identified. Although procedures can...... be suggested to eliminate the shallow trap effects, it appears that the deep trap effects cannot be removed. The character of the sensitivity changes which result from these effects is seen to be dependent upon several external parameters, including the extent of bleaching of the OSL signal, the laboratory...

  17. A luminescence imaging system for the routine measurement of single-grain OSL dose distributions

    DEFF Research Database (Denmark)

    Kook, Myung Ho; Lapp, Torben; Murray, Andrew

    2015-01-01

    the potential of an electron multiplying charge-coupled device (EMCCD), providing extremely low level light detection. We characterize the performance of the device by discussing reproducibility and evaluating uncertainties in OSL signals. Finally we derive a typical single grain natural dose distribution...

  18. Dose evaluation using multiple-aliquot quartz OSL: Test of methods and a new protocol for improved accuracy and precision

    DEFF Research Database (Denmark)

    Jain, M.; Bøtter-Jensen, L.; Singhvi, A.K.

    2003-01-01

    -dose-dependent sensitivity changes during the pre-heat, and fundamental variability in the shapes of quartz OSL (blue-green or blue-light stimulated luminescence) decay forms. A new protocol using a combination of 'elevated temperature IR cleaning' (ETIR) and 'component-specific dose normalisation' (CSDN) has been developed....... CSDN accounts for variability in the OSL decay forms and absorbs such sensitivity changes. A combination of ETIR and CSDN protocol increased palaeodose precision from +/-100% to +/-4% in quartz separates from the fluvially transported sands in the Thar desert. A comparison with palaeodose estimates...

  19. A new method for measuring bioturbation rates in sandy tidal flat sediments based on luminescence dating

    DEFF Research Database (Denmark)

    Madsen, Anni T.; Murray, Andrew S.; Jain, Mayank

    2011-01-01

    The rates of post-depositional mixing by bioturbation have been investigated using Optically Stimulated Luminescence (OSL) dating in two sediment cores (BAL2 and BAL5), retrieved from a sandy tidal flat in the Danish part of the Wadden Sea. A high-resolution chronology, consisting of thirty-six OSL...

  20. Real time dose rate measurements with fiber optic probes based on the RL and OSL of beryllium oxide

    International Nuclear Information System (INIS)

    Teichmann, T.; Sponner, J.; Jakobi, Ch.; Henniger, J.

    2016-01-01

    This work covers the examination of fiber optical probes based on the radioluminescence and real time optically stimulated luminescence of beryllium oxide. Experiments are carried out to determine the fundamental dosimetric and temporal properties of the system and evaluate its suitability for dose rate measurements in brachytherapy and other applications using non-pulsed radiation fields. For this purpose the responses of the radioluminescence and optically stimulated luminescence signal have been investigated in the dose rate range of 20 mGy/h to 3.6 Gy/h and for doses of 1 mGy up to 6 Gy. Furthermore, a new, efficient analysis procedure, the double phase reference summing, is introduced, leading to a real time optically stimulated luminescence signal. This method allows a complete compensation of the stem effect during the measurement. In contrast to previous works, the stimulation of the 1 mm cylindrical beryllium oxide detectors is performed with a symmetric function during irradiation. The investigated dose rates range from 0.3 to 3.6 Gy/h. The real time optically stimulated luminescence signal of beryllium oxide shows a dependency on both the dose rate and the applied dose. To overcome the problem of dose dependency, further experiments using higher stimulation intensities have to follow. - Highlights: • RL and OSL measurements with BeO extended to low dose (rate) range. • A new method to obtain the real time OSL: Dual Phase Reference Summing. • Real time OSL signal shows both dose and dose rate dependency. • Real time OSL enables a complete discrimination of the stem effect.

  1. Intercomparison of dispersed radiation readings among film dosimetry, electronic and OSL with X-rays for low dose; Intercomparacion de lecturas de radiacion dispersa entre dosimetria film, electronica y OSL con rayos X para dosis bajas

    Energy Technology Data Exchange (ETDEWEB)

    Andisco, D. [Universidad de Buenos Aires, Facultad de Medicina, Paraguay 2155, C1121AAA Buenos Aires (Argentina); Blanco, S. [CONICET, Saavedra 15, C1083ACA Buenos Aires (Argentina); Bourel, V.; Schmidt, L. [Universidad Favaloro, Facultad de Ciencias e Ingenieria, Solis 453, C1078AAI, Buenos Aires (Argentina); Di Risio, C., E-mail: dandisco@fmed.uba.ar [Universidad de Belgrano, Facultad de Ingenieria, Zabala 1837, C1426DQG, Buenos Aires (Argentina)

    2014-08-15

    One of the personal dosimetry methods more used for several decades is the dosimetry type film, characterized to possess readings with certain margin of trust. Today other methods exist that many times are presupposed more reliable due to the nature of the detection like the electronic dosimeters or the OSL (Optically Stimulated Luminescence) dosimetry. With the purpose of comparing different methods and to can determining the existent differences among each method has been carried out an intercomparison assay. The different dosimeters have been exposed to dispersed radiation generated by a Hemodynamics equipment of the type -arch in C- and a dispersing system of the primary beam. Film dosimeters have been used; OSL (In Light), OSL (Nano Dots) and Electronic with the purpose of knowing and to valorize the existent differences among its readings. Always, the intercomparison exercises have demonstrated to be an useful tool when establishing the measurement capacity and the quality of the results emitted by the laboratories of personal dosimetry services. Also, this type of assays allows obtaining quality indicators of the laboratory performance and they are habitual part of the procedures for accreditation of the same ones. The Optically Stimulated Luminescence is a technology that has grown in Argentina so much in the area of personal dosimetry as in dosimetry in vivo (radiotherapy area). In this intercomparison study, the answers corresponding to each technology were looked for oneself irradiation of the disperse type, that is to say, of very low energy. (Author)

  2. TL, OSL and C-14 dating results of the sediments and bricks from mummified nuns' grave

    Directory of Open Access Journals (Sweden)

    Diego R.G. Tudela

    2012-06-01

    Full Text Available This paper presents the results of TL and OSL dating of soil and fragments of bricks from a grave, which was occupied by two mummified nuns, found at "Luz" Monastery, located in the state of São Paulo, Brazil. The TL and OSL ages were compared to C-14 dating ones obtained from bone collagens of the mummies. The majority of the ages is related to the eighteenth century. The gamma-ray spectroscopy was used to evaluate natural radioisotope concentrations in the samples, and by using these concentrations the annual dose rates, from 3.0 to 5.3 Gy/kyr, were obtained. Neutron activation analysis was performed and the radioisotope contents results are in agreement with those obtained by gamma-ray spectroscopy. The contents of U, Th and Ce elements were higher than those found in usual sediments.Este artigo apresenta os resultados de datação por TL e OSL de solos, e fragmentos de tijolos de um túmulo, que foi ocupado por duas freiras mumificadas encontradas no Mosteiro da "Luz", localizado no Estado de São Paulo, Brasil. As idades encontradas por TL e OSL foram comparadas às obtidas a partir de C-14 dos colágenos contidos em amostras de osso das múmias. A maioria das idades obtidas são do século XVIII. A espectroscopia de radiação-gama foi utilizada para avaliar concentrações de radioisótopos naturais nas amostras e para calcular as taxas de dose anual que resultaram em 3,0 a 5,3 Gy/kano. As concentrações radioativas são próximas daquelas obtidas através de Análise por Ativação de Nêutrons. Os conteúdos de elementos U, Th e Ce são superiores aos encontrados na maioria dos sedimentos.

  3. Resetting of Quartz OSL (optically stimulated luminescence) Signals by Frictional Heating in Experimentally Sheared Gouges at Seismic Slip Rates.

    Science.gov (United States)

    Kim, J. H.; Choi, J. H.; Chauhan, N.; Lee, S.; Hirose, T.; Ree, J. H.

    2014-12-01

    Recent studies on natural and experimental seismic faults have revealed that frictional heating plays an important role in earthquake dynamics as well as in producing mineralogical and microstructural signatures of seismic faulting. Here, we report changes in OSL signals in quartz by frictional heating in experimental fault gouges. The gouges (80% of quartz and 20% of bentonite by weight) with a thickness of 1 mm were sheared between sandstone cylinders (diameter: 25 mm) at a normal stress of 1 MPa and slip rate of 1.31 m/s. The quartz grains from a sand dune on the western coast of South Korea were sieved to select size fractions between 90 and 250 μm. The equivalent dose (De) of the undeformed quartz grains was 8.0 ± 0.3 Gy. Upon displacement, the friction abruptly increases to the 1st peak (with friction coefficient μ ≈ 0.75) followed by slip weakening. Then the fault zones show two more peak frictions (μ ≈ 0.53~0.75) and finally reach a steady-state friction (μ ≈ 0.2~0.35). The fault can be divided into three zones based grain size (thus slip rate); slip localization (SLZ), intermediate slip-rate (ISZ) and low slip-rate (LSZ) zones. SLZ develops adjacent to the moving side of the sandstone cylinder with P-foliation and shear band. The size of quartz (Dq) in ISZ and LSZ is 5-30 μm and 50-250 μm, respectively. SEM and TEM analyses indicate that the fault gouge of SLZ consists of subangular quartz clasts (Dq ≈ 3 μm) and matrix of nano-scale quartz, unidentified silicate minerals and amorphous material. The fault zones were sectioned into six layers (~160 µm thick for each layer) parallel to the fault zone boundary for OSL analyses. Quartz grains from all the layers except the one immediately adjacent to the stationary side of the sandstone cylinder show De of 'effectively' 0 Gy indicating a full resetting of OSL signals. The partial resetting of OSL signal in the layer adjacent to the stationary side of the cylinder indicates the temperature (T

  4. Application of pulsed OSL to the separation of the luminescence components from a mixed quartz/feldspar sample

    DEFF Research Database (Denmark)

    Denby, Phil M.; Bøtter-Jensen, L.; Murray, A.S.

    2006-01-01

    with a feldspar signal. We have developed instrumentation for the study of high-speed pulse stimulated OSL. Our system uses the standard blue/IR LED stimulation unit of a Riso reader (allowing stimulation pulses down to 1-2 mu s duration) and can thus be applied to the routine analysis of samples. Using...... that counts are only accumulated during a windowed period, reduces the feldspar signal to 1.6% of its original value relative to that of the quartz. (c) 2006 Elsevier Ltd. All rights reserved....

  5. PIXE multivariate statistics and OSL investigation for the classification and dating of archaeological pottery excavated at Tell Al-Rawda site, Syria

    Energy Technology Data Exchange (ETDEWEB)

    Bakraji, E.H., E-mail: cscientificl@aec.org.sy [Archaeometry Laboratory, Chemistry Department, Atomic Energy Commission of Syria, P. O. Box 6091, Damascus (Syrian Arab Republic); Rihawy, M.S. [Archaeometry Laboratory, Chemistry Department, Atomic Energy Commission of Syria, P. O. Box 6091, Damascus (Syrian Arab Republic); Castel, C. [CNRS – Maison de l’Orient et de la Méditerranée, Laboratoire “Archéorient”, CNRS/Université Lumière-Lyon 2 (France); Abboud, R. [Archaeometry Laboratory, Chemistry Department, Atomic Energy Commission of Syria, P. O. Box 6091, Damascus (Syrian Arab Republic)

    2015-03-15

    Highlights: •PIXE and OSL methods were used to classify and date pottery from Tell Al-Rawda site. •Three groups were classified using PIXE, which suggest different sources of the clay. •OSL was used for dating the site and the date found was consistent with typology. -- Abstract: Particle Induced X-ray Emission (PIXE) technique has been utilised to study 48 Syrian ancient pottery fragments taken from excavations at Tell Al-Rawda site. Eighteen elements (Mg, Al, Si, P, S, K, Ca, Ti, Mn, Fe, Ni, Zn, As, Br, Rb, Sr, Y, and Pb) were determined. The elements concentrations have been processed using two multivariate statistical methods, to classify the pottery where one main group and other two small groups were defined. In addition, four samples from different places on the site were subjected to optically stimulated luminescence (OSL) dating. The average age obtained using a single aliquot regeneration (SAR) protocol was found to be 4350 ± 240 year.

  6. Establishing a luminescence chronology for a palaeosol-loess profile at Tokaj (Hungary): A comparison of quartz OSL and polymineral IRSL signals

    DEFF Research Database (Denmark)

    Schatz, Ann-Kathrin; Buylaert, Jan-Pieter; Murray, Andrew

    2012-01-01

    We present a comparative study of quartz OSL, polymineral IRSL at low temperature (50 °C, IR50) and post-IR elevated temperature (290 °C) IRSL (pIRIR290) feldspar dating on nine samples from the Tokaj loess section in NE Hungary (SE Europe). Preheat plateau tests show a drop in quartz OSL De...... between 160 and 240 °C but above 240 °C a clear De plateau is present. Quartz OSL SAR is shown to be generally appropriate to these samples (recycling, recuperation) but a satisfactory dose recovery result was only obtained when a dose was added to a sample without any prior optical or thermal pre...... of the Tokaj loess has been deposited during MIS 3 (60–24 ka), with periods of soil formation occurring during the onset of MIS 3 (≥58 ka) and between about 35 and 25 ka. Our results also indicate episodic deposition of loess and varying, non-linear sedimentation rates during MIS 3. Proxy analyses...

  7. PIXE multivariate statistics and OSL investigation for the classification and dating of archaeological pottery excavated at Tell Al-Rawda site, Syria

    International Nuclear Information System (INIS)

    Bakraji, E.H.; Rihawy, M.S.; Castel, C.; Abboud, R.

    2015-01-01

    Highlights: •PIXE and OSL methods were used to classify and date pottery from Tell Al-Rawda site. •Three groups were classified using PIXE, which suggest different sources of the clay. •OSL was used for dating the site and the date found was consistent with typology. -- Abstract: Particle Induced X-ray Emission (PIXE) technique has been utilised to study 48 Syrian ancient pottery fragments taken from excavations at Tell Al-Rawda site. Eighteen elements (Mg, Al, Si, P, S, K, Ca, Ti, Mn, Fe, Ni, Zn, As, Br, Rb, Sr, Y, and Pb) were determined. The elements concentrations have been processed using two multivariate statistical methods, to classify the pottery where one main group and other two small groups were defined. In addition, four samples from different places on the site were subjected to optically stimulated luminescence (OSL) dating. The average age obtained using a single aliquot regeneration (SAR) protocol was found to be 4350 ± 240 year

  8. Ultra-high resolution protein crystallography

    International Nuclear Information System (INIS)

    Takeda, Kazuki; Hirano, Yu; Miki, Kunio

    2010-01-01

    Many protein structures have been determined by X-ray crystallography and deposited with the Protein Data Bank. However, these structures at usual resolution (1.5< d<3.0 A) are insufficient in their precision and quantity for elucidating the molecular mechanism of protein functions directly from structural information. Several studies at ultra-high resolution (d<0.8 A) have been performed with synchrotron radiation in the last decade. The highest resolution of the protein crystals was achieved at 0.54 A resolution for a small protein, crambin. In such high resolution crystals, almost all of hydrogen atoms of proteins and some hydrogen atoms of bound water molecules are experimentally observed. In addition, outer-shell electrons of proteins can be analyzed by the multipole refinement procedure. However, the influence of X-rays should be precisely estimated in order to derive meaningful information from the crystallographic results. In this review, we summarize refinement procedures, current status and perspectives for ultra high resolution protein crystallography. (author)

  9. TL, OSL and C-14 dating results of the sediments and bricks from mummified nuns' grave

    International Nuclear Information System (INIS)

    Tudela, Diego R.G.; Tatumi, Sonia H.; Yee, Marcio; Brito, Silvio L.M.

    2012-01-01

    This paper presents the results of TL and OSL dating of soil and fragments of bricks from a grave, which was occupied by two mummified nuns, found at 'Luz' Monastery, located in the state of Sao Paulo, Brazil. The TL and OSL ages were compared to C-14 dating ones obtained from bone collagens of the mummies. The majority of the ages is related to the eighteenth century. The gamma-ray spectroscopy was used to evaluate natural radioisotope concentrations in the samples, and by using these concentrations the annual dose rates, from 3.0 to 5.3 Gy/kyr, were obtained. Neutron activation analysis was performed and the radioisotope contents results are in agreement with those obtained by gamma-ray spectroscopy. The contents of U, Th and Ce elements were higher than those found in usual sediments. (author)

  10. High resolution solar observations

    International Nuclear Information System (INIS)

    Title, A.

    1985-01-01

    Currently there is a world-wide effort to develop optical technology required for large diffraction limited telescopes that must operate with high optical fluxes. These developments can be used to significantly improve high resolution solar telescopes both on the ground and in space. When looking at the problem of high resolution observations it is essential to keep in mind that a diffraction limited telescope is an interferometer. Even a 30 cm aperture telescope, which is small for high resolution observations, is a big interferometer. Meter class and above diffraction limited telescopes can be expected to be very unforgiving of inattention to details. Unfortunately, even when an earth based telescope has perfect optics there are still problems with the quality of its optical path. The optical path includes not only the interior of the telescope, but also the immediate interface between the telescope and the atmosphere, and finally the atmosphere itself

  11. High speed, High resolution terahertz spectrometers

    International Nuclear Information System (INIS)

    Kim, Youngchan; Yee, Dae Su; Yi, Miwoo; Ahn, Jaewook

    2008-01-01

    A variety of sources and methods have been developed for terahertz spectroscopy during almost two decades. Terahertz time domain spectroscopy (THz TDS)has attracted particular attention as a basic measurement method in the fields of THz science and technology. Recently, asynchronous optical sampling (AOS)THz TDS has been demonstrated, featuring rapid data acquisition and a high spectral resolution. Also, terahertz frequency comb spectroscopy (TFCS)possesses attractive features for high precision terahertz spectroscopy. In this presentation, we report on these two types of terahertz spectrometer. Our high speed, high resolution terahertz spectrometer is demonstrated using two mode locked femtosecond lasers with slightly different repetition frequencies without a mechanical delay stage. The repetition frequencies of the two femtosecond lasers are stabilized by use of two phase locked loops sharing the same reference oscillator. The time resolution of our terahertz spectrometer is measured using the cross correlation method to be 270 fs. AOS THz TDS is presented in Fig. 1, which shows a time domain waveform rapidly acquired on a 10ns time window. The inset shows a zoom into the signal with 100ps time window. The spectrum obtained by the fast Fourier Transformation (FFT)of the time domain waveform has a frequency resolution of 100MHz. The dependence of the signal to noise ratio (SNR)on the measurement time is also investigated

  12. Evaluation of aluminum oxide dosimeters using OSL technique in dosimetry of clinical photon beams on volumetric modulated arc treatment

    International Nuclear Information System (INIS)

    Villani, Daniel

    2017-01-01

    Treatment using Volumetric Modulated Arc Radiation Therapy is the most modern modality of conformational radiotherapy so that, with the overlapping of several fields, the dose distributions provide a perfect conformation to the tumor, reducing the probability of complications in adjacent normal tissues. In this sense, many efforts are being invested to improve dose distribution compliance as well as the integration of imaging techniques for tumor screening and correction of inter and intrafraction variations. To this end, an intensive monitoring of the quality of the processes and a quality assurance program are fundamental for patient safety and compliance with current legislation; besides the use of different dosimetry methodologies for intercomparison and validation of the results. The aim of this study is to evaluate and compare the performance of aluminum oxide (Al_2O_3:C) OSL dosimeters manufactured by Landauer Inc. with those produced by Rexon™ in the dosimetry of high energy photon clinical bundles used in Volumetric Modulated Arc Therapy - (VMAT) using different simulating objects. The dosimeters were characterized for gamma radiation of the "6"0Co and for clinical photon beams of 6 MV typical of treatments by VMAT under conditions of electronic equilibrium and maximum dose respectively. Performance tests of the TL and OSL readers used and repeatability of the samples were evaluated. After all tests, the dosimeters were irradiated in the simulation of different radiotherapy treatments by VMAT and their responses compared to the planning system. All types of dosimeters presented satisfactory results in verifying the doses of this type of planning simulation. The Al_2O_3:C dosimeters presented compatible results and validated by the other dosimeters and ionization chamber. Regarding the best technique, the OSL InLight commercial system presents greater practicality and versatility for use and application in the clinical routine. (author)

  13. A primary assessment of a daybreak 2200 OSL reader using fine grain quartz and CaSO4:Tm TLD

    International Nuclear Information System (INIS)

    Zhang Keqi; Chen Jie; Lu Yanchou; Wang Changsheng; Yang Chuancheng

    2007-01-01

    Daybreak 2200 OSL readers are widely used for luminescence dating applications. As the sample irradiation and illumination may affect discs in adjacent positions, it is critical to confirm that these factors do not introduce significant systematic errors. Effects of cross-irradiation and cross-bleaching were examined and quantified using fine-grain quartz and highly sensitive CaSO 4 :Tm dosimeters, and the irradiation offset time was measured. The cross-bleaching effect on adjacent aliquots is non-linear with no more than 15% OSL signal reduction following 10ks illumination with the power of blue LED being at 95% maximum. But at positions other than the nearest neighboring sample, almost no effect of cross-bleaching was found. The cross-talk dose, even to the nearest samples, was about 0.02% of the applied dose, and it decreased with increasing distance from the source. Offset time of the built-in Beta source shutter is 0.22 s, which can be neglected in regular dating, and leak dose of the source can be ignored as well. Finally, measurement consistency at Position 0.5, 10, ..... and 55 of the sample tray is better than 3% in relative standard deviation. (authors)

  14. Assessment of influence of OSL dosimeters in the skin dose in radiotherapy: study for Monte Carlo simulation; Avaliacao da influencia de dosimetros OSL na dose na pele em radioterapia: estudo por simulacao Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Schuch, Franciely F.; Nicolucci, Patricia, E-mail: franschuch@yahoo.com.br [Universidade de Sao Paulo (USP), Ribeiraoo Preto, SP (Brazil)

    2017-11-01

    The interest in optically stimulated luminescence (OSL) dosimetry materials is growing due to its potential use in quality control in Radiotherapy. The use of these dosimeters for in vivo dosimetry, however, may influence the dose to the skin and deeper tissues in the patient. The goal of this study is to evaluate the influence of the OSL Al{sub 2}O{sub 3} material in dose deposited in the skin and deep in Radiotherapy. Monte Carlo simulation is used to evaluate this purpose when OSL dosimeters of Al{sub 2}O{sub 3} are positioned on the skin surface of the patient. Percentage depth dose curves for clinical beams of 6 and 10 MV were simulated with and without the presence of the dosimeter on the surface of a water phantom. The results showed a decrease of doses in regions close to the surface of the skin. In the build-up region, the maximum decreases of dose produced by the presence of the dosimeters were 52,5% and 47,5% for the 6 and 10 MV beams, respectively. After the build-up region, there are not significant changes in the doses for any of the used beams. The differences of doses found are due to the influence of the dosimetric material on the relative fluence of electrons near the end surface of the dosimeter. Thus, the results showed that the presence of the dosimetric material on the surface interferes on the skin dose. However, these dosimeters do not cause dose variations in depths of clinical interest, allowing its application in routine in vivo dosimetry in Radiotherapy. (author)

  15. Single-grain OSL dating of Early Middle Palaeolithic deposits at Cuesta de la Bajada, Ebro Basin, Spain

    Science.gov (United States)

    Arnold, Lee; Demuro, Martina; Santonja, Manuel; Perez-Gonzalez, Alfredo; Pares, Josep

    2013-04-01

    -response curves with very high saturation limits. The latter offers the advantage of extending the age range over which single-grain techniques can be applied in this Middle Pleistocene context. Dose-recovery tests performed at high doses of 470 Gy yielded accurate equivalent dose (De) results with low overdispersion, providing reasonable confidence in the chosen measurement conditions. Three of the samples display single-grain De distributions with low levels of dispersion indicating that the sediments were adequately bleached prior to burial and remained undisturbed thereafter. The fourth sample displays higher De dispersion and a younger subpopulation of grains, which could be explained by beta-dose heterogeneity associated with interspersed gravels within the basal archaeological horizon. We apply various statistical age models to derive final chronologies and compare the resultant single-grain ages with those obtained using different absolute dating methods. We also report on experiments performed using 'synthetic multi-grain aliquots' created from the single-grain De datasets, and discuss their implications for the reliability of multi-grain OSL dating techniques in this context.

  16. SU-F-T-327: Total Body Irradiation In-Vivo Dose Measurements Using Optically Stimulated Luminescence (OSL) NanoDots and Farmer Type Ion Chamber

    International Nuclear Information System (INIS)

    Kaur, H; Kumar, S; Sarkar, B; Ganesh, T; Giri, U; Jassal, K; Rathinamuthu, S; Gulia, G; Gopal, V; Mohanti, B; Munshi, A

    2016-01-01

    Purpose: This study was performed to analyze the agreement between optically stimulated luminescence (OSL) nanoDots measured doses and 0.6 cc Farmer type ionization chamber measured doses during total body irradiation (TBI). Methods: In-vivo dose measurements using OSL nanoDots and Farmer chamber were done in a total of twelve patients who received TBI at our center by bilateral parallel-opposed beams technique. In this technique, the patient is kept inside the TBI box which is filled with rice bags and irradiated using two bilateral parallel opposed beams of 40×40 cm"2 size with 45° collimator rotation at an SSD of 333.5 cm in an Elekta Synergy linear accelerator. All patients received a dose of 2 Gy in single fraction as conditioning regimen. The beams were equally weighted at the midplane of the box. The nanoDots were placed over forehead, right and left neck, right and left lung, umbilicus, right and left abdomen, medial part of thigh, knee and toe. A 0.6 cc Farmer chamber was placed in between the thighs of the patient. Measured doses are reported along with the statistical comparisons using paired sample t-test. Results: For the above sites the mean doses were 212.2±21.1, 218.2±7.6, 218.7±9.3, 215.6±9.5, 217.5±11.5, 214.5±7.7, 218.3±6.8, 221.5±15, 229.1±11.0, 220.5±7.7 and 223.3±5.1 cGy respectively. For all OSL measurements the mean dose was 218.6±11.8 cGy. Farmer chamber measurements yielded a mean dose of 208.8±15.6 cGy. Statistical analysis revealed that there was no significant difference between OSL measured doses in forehead, right and left neck, right and left lung, umbilicus, right and left abdomen and toe and Farmer chamber measured doses (0.72≤p≤0.06). However the mean OSL doses at thigh and knee were statistically different (p<0.05) from the Farmer chamber measurements. Conclusion: OSL measurements were found to be in agreement with Farmer type ionization chamber measurements in in-vivo dosimetry of TBI.

  17. High-Resolution Sonars: What Resolution Do We Need for Target Recognition?

    Directory of Open Access Journals (Sweden)

    Pailhas Yan

    2010-01-01

    Full Text Available Target recognition in sonar imagery has long been an active research area in the maritime domain, especially in the mine-counter measure context. Recently it has received even more attention as new sensors with increased resolution have been developed; new threats to critical maritime assets and a new paradigm for target recognition based on autonomous platforms have emerged. With the recent introduction of Synthetic Aperture Sonar systems and high-frequency sonars, sonar resolution has dramatically increased and noise levels decreased. Sonar images are distance images but at high resolution they tend to appear visually as optical images. Traditionally algorithms have been developed specifically for imaging sonars because of their limited resolution and high noise levels. With high-resolution sonars, algorithms developed in the image processing field for natural images become applicable. However, the lack of large datasets has hampered the development of such algorithms. Here we present a fast and realistic sonar simulator enabling development and evaluation of such algorithms.We develop a classifier and then analyse its performances using our simulated synthetic sonar images. Finally, we discuss sensor resolution requirements to achieve effective classification of various targets and demonstrate that with high resolution sonars target highlight analysis is the key for target recognition.

  18. Evaluation of aluminum oxide dosimeters using OSL technique in dosimetry of clinical photon beams on volumetric modulated arc treatment; Avaliacao de dosimetros de oxido de aluminio pela tecnica OSL na dosimetria de campos de fotons clinicos utilizados no tratamento radioterapico em arco modulado volumetrico

    Energy Technology Data Exchange (ETDEWEB)

    Villani, Daniel

    2017-07-01

    Treatment using Volumetric Modulated Arc Radiation Therapy is the most modern modality of conformational radiotherapy so that, with the overlapping of several fields, the dose distributions provide a perfect conformation to the tumor, reducing the probability of complications in adjacent normal tissues. In this sense, many efforts are being invested to improve dose distribution compliance as well as the integration of imaging techniques for tumor screening and correction of inter and intrafraction variations. To this end, an intensive monitoring of the quality of the processes and a quality assurance program are fundamental for patient safety and compliance with current legislation; besides the use of different dosimetry methodologies for intercomparison and validation of the results. The aim of this study is to evaluate and compare the performance of aluminum oxide (Al{sub 2}O{sub 3}:C) OSL dosimeters manufactured by Landauer Inc. with those produced by Rexon™ in the dosimetry of high energy photon clinical bundles used in Volumetric Modulated Arc Therapy - (VMAT) using different simulating objects. The dosimeters were characterized for gamma radiation of the {sup 60}Co and for clinical photon beams of 6 MV typical of treatments by VMAT under conditions of electronic equilibrium and maximum dose respectively. Performance tests of the TL and OSL readers used and repeatability of the samples were evaluated. After all tests, the dosimeters were irradiated in the simulation of different radiotherapy treatments by VMAT and their responses compared to the planning system. All types of dosimeters presented satisfactory results in verifying the doses of this type of planning simulation. The Al{sub 2}O{sub 3}:C dosimeters presented compatible results and validated by the other dosimeters and ionization chamber. Regarding the best technique, the OSL InLight commercial system presents greater practicality and versatility for use and application in the clinical routine

  19. Intercomparison of dispersed radiation readings among film dosimetry, electronic and OSL with X-rays for low dose

    International Nuclear Information System (INIS)

    Andisco, D.; Blanco, S.; Bourel, V.; Schmidt, L.; Di Risio, C.

    2014-08-01

    One of the personal dosimetry methods more used for several decades is the dosimetry type film, characterized to possess readings with certain margin of trust. Today other methods exist that many times are presupposed more reliable due to the nature of the detection like the electronic dosimeters or the OSL (Optically Stimulated Luminescence) dosimetry. With the purpose of comparing different methods and to can determining the existent differences among each method has been carried out an intercomparison assay. The different dosimeters have been exposed to dispersed radiation generated by a Hemodynamics equipment of the type -arch in C- and a dispersing system of the primary beam. Film dosimeters have been used; OSL (In Light), OSL (Nano Dots) and Electronic with the purpose of knowing and to valorize the existent differences among its readings. Always, the intercomparison exercises have demonstrated to be an useful tool when establishing the measurement capacity and the quality of the results emitted by the laboratories of personal dosimetry services. Also, this type of assays allows obtaining quality indicators of the laboratory performance and they are habitual part of the procedures for accreditation of the same ones. The Optically Stimulated Luminescence is a technology that has grown in Argentina so much in the area of personal dosimetry as in dosimetry in vivo (radiotherapy area). In this intercomparison study, the answers corresponding to each technology were looked for oneself irradiation of the disperse type, that is to say, of very low energy. (Author)

  20. TL, OSL and C-14 dating results of the sediments and bricks from mummified nuns' grave

    Energy Technology Data Exchange (ETDEWEB)

    Tudela, Diego R.G.; Tatumi, Sonia H.; Yee, Marcio; Brito, Silvio L.M., E-mail: tatumi@fatecsp.br [Faculdades de Tecnologia de Sao Paulo (FATECs/CEETEPS/UNESP), Sao Paulo, SP (Brazil). Centro Estadual de Educacao Tecnologica Paula Souza; Morais, Jose L.; Morais, Daisy de; Piedade, Silvia C. [Universidade de Sao Paulo (USP), SP (Brazil). Museu de Arqueologia e Etnologia; Munita, Casimiro S.P.; Hazenfratz, Roberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2012-06-15

    This paper presents the results of TL and OSL dating of soil and fragments of bricks from a grave, which was occupied by two mummified nuns, found at 'Luz' Monastery, located in the state of Sao Paulo, Brazil. The TL and OSL ages were compared to C-14 dating ones obtained from bone collagens of the mummies. The majority of the ages is related to the eighteenth century. The gamma-ray spectroscopy was used to evaluate natural radioisotope concentrations in the samples, and by using these concentrations the annual dose rates, from 3.0 to 5.3 Gy/kyr, were obtained. Neutron activation analysis was performed and the radioisotope contents results are in agreement with those obtained by gamma-ray spectroscopy. The contents of U, Th and Ce elements were higher than those found in usual sediments. (author)

  1. Berkeley High-Resolution Ball

    International Nuclear Information System (INIS)

    Diamond, R.M.

    1984-10-01

    Criteria for a high-resolution γ-ray system are discussed. Desirable properties are high resolution, good response function, and moderate solid angle so as to achieve not only double- but triple-coincidences with good statistics. The Berkeley High-Resolution Ball involved the first use of bismuth germanate (BGO) for anti-Compton shield for Ge detectors. The resulting compact shield permitted rather close packing of 21 detectors around a target. In addition, a small central BGO ball gives the total γ-ray energy and multiplicity, as well as the angular pattern of the γ rays. The 21-detector array is nearly complete, and the central ball has been designed, but not yet constructed. First results taken with 9 detector modules are shown for the nucleus 156 Er. The complex decay scheme indicates a transition from collective rotation (prolate shape) to single- particle states (possibly oblate) near spin 30 h, and has other interesting features

  2. Stability of fine-grained TT-OSL and post-IR IRSL signals from a c. 1 Ma sequence of aeolian and lacustrine deposits from the Nihewan Basin (northern China)

    DEFF Research Database (Denmark)

    Liu, Jinfeng; Murray, Andrew Sean; Buylaert, Jan-Pieter

    2016-01-01

    We tested the suitability of the fine-grained quartz (4–11 μm) Optical Stimulated Luminescence (OSL) and thermally-transferred OSL (TT-OSL), and the fine-grained polymineral (4–11 μm) post-infrared IRSL (post-IR IRSL or pIRIR) signals for dating samples from aeolian-lacustrine deposits from...... accurate ones; nevertheless, these ages provide the first long series absolute chronology for study of local palaeolithic and geomorphic evolution history aside from the  magnetostratigraphical results available before this research....

  3. SU-F-T-327: Total Body Irradiation In-Vivo Dose Measurements Using Optically Stimulated Luminescence (OSL) NanoDots and Farmer Type Ion Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, H; Kumar, S; Sarkar, B; Ganesh, T; Giri, U; Jassal, K; Rathinamuthu, S; Gulia, G; Gopal, V; Mohanti, B; Munshi, A [Fortis Memorial Research Institute, Gurgaon, Haryana (India)

    2016-06-15

    Purpose: This study was performed to analyze the agreement between optically stimulated luminescence (OSL) nanoDots measured doses and 0.6 cc Farmer type ionization chamber measured doses during total body irradiation (TBI). Methods: In-vivo dose measurements using OSL nanoDots and Farmer chamber were done in a total of twelve patients who received TBI at our center by bilateral parallel-opposed beams technique. In this technique, the patient is kept inside the TBI box which is filled with rice bags and irradiated using two bilateral parallel opposed beams of 40×40 cm{sup 2} size with 45° collimator rotation at an SSD of 333.5 cm in an Elekta Synergy linear accelerator. All patients received a dose of 2 Gy in single fraction as conditioning regimen. The beams were equally weighted at the midplane of the box. The nanoDots were placed over forehead, right and left neck, right and left lung, umbilicus, right and left abdomen, medial part of thigh, knee and toe. A 0.6 cc Farmer chamber was placed in between the thighs of the patient. Measured doses are reported along with the statistical comparisons using paired sample t-test. Results: For the above sites the mean doses were 212.2±21.1, 218.2±7.6, 218.7±9.3, 215.6±9.5, 217.5±11.5, 214.5±7.7, 218.3±6.8, 221.5±15, 229.1±11.0, 220.5±7.7 and 223.3±5.1 cGy respectively. For all OSL measurements the mean dose was 218.6±11.8 cGy. Farmer chamber measurements yielded a mean dose of 208.8±15.6 cGy. Statistical analysis revealed that there was no significant difference between OSL measured doses in forehead, right and left neck, right and left lung, umbilicus, right and left abdomen and toe and Farmer chamber measured doses (0.72≤p≤0.06). However the mean OSL doses at thigh and knee were statistically different (p<0.05) from the Farmer chamber measurements. Conclusion: OSL measurements were found to be in agreement with Farmer type ionization chamber measurements in in-vivo dosimetry of TBI.

  4. High-Resolution PET Detector. Final report

    International Nuclear Information System (INIS)

    Karp, Joel

    2014-01-01

    The objective of this project was to develop an understanding of the limits of performance for a high resolution PET detector using an approach based on continuous scintillation crystals rather than pixelated crystals. The overall goal was to design a high-resolution detector, which requires both high spatial resolution and high sensitivity for 511 keV gammas. Continuous scintillation detectors (Anger cameras) have been used extensively for both single-photon and PET scanners, however, these instruments were based on NaI(Tl) scintillators using relatively large, individual photo-multipliers. In this project we investigated the potential of this type of detector technology to achieve higher spatial resolution through the use of improved scintillator materials and photo-sensors, and modification of the detector surface to optimize the light response function.We achieved an average spatial resolution of 3-mm for a 25-mm thick, LYSO continuous detector using a maximum likelihood position algorithm and shallow slots cut into the entrance surface

  5. Single-grain and multi-grain OSL dating of river terrace sediments in the Tabernas Basin, SE Spain

    DEFF Research Database (Denmark)

    Geach, M.R.; Thomsen, Kristina Jørkov; Buylaert, Jan-Pieter

    2015-01-01

    River terraces represent important records of landscape response to e.g. base-level change and tectonicmovement. Both these driving forces are important in the southern Iberian Peninsula. In this study,Optically Stimulated Luminescence (OSL) dating was used to date two principal river terraces...

  6. High resolution luminescence chronology for Xiashu Loess deposits of Southeastern China

    Science.gov (United States)

    Yi, Shuangwen; Li, Xusheng; Han, Zhiyong; Lu, Huayu; Liu, Jinfeng; Wu, Jiang

    2018-04-01

    Loess deposits in Xiashu are representative of such deposits in Southeastern China that are mainly distributed in the middle and lower reaches of the Yangtze River valley. These loess-paleosol sequences provide a key archive of past climate change in humid, subtropical regions. However, the ages of the sequences are not well constrained. In this study, the standard quartz single-aliquot regenerative (SAR) dose optically stimulated luminescence (OSL) and K-feldspar post-infrared infrared stimulated luminescence (post-IR IRSL; pIRIR290) methods are used to date two loess sequences in Nanjing region. Our results show that quartz SAR OSL and K-feldspar pIRIR290 ages are more or less indistinguishable from one another up to ∼50 ka. Beyond this age, the K-feldspar pIRIR ages increased systematically with deposition depth, agreeing well with the expected ages as far as ∼200 ka. On the basis of a fully independently-dated timescale, we are therefore able to propose, for the first time, a new age model for the Xiashu Loess deposits accumulated since the penultimate interglacial period. Using our newly obtained luminescence dating ages, we observe a marked difference between the loess accumulation rates in the two sequences, potentially forced by regional depositional processes and loess preservation.

  7. Effect of high-dose irradiation on the optically stimulated luminescence of Al{sub 2}O{sub 3}:C

    Energy Technology Data Exchange (ETDEWEB)

    Yukihara, E.G. E-mail: yukihara@thor.phy.okstate.edu; Whitley, V.H.; McKeever, S.W.S. E-mail: swsm@okstate.edu; Akselrod, A.E.; Akselrod, M.S

    2004-06-01

    This paper examines the effect of high-dose irradiation on the optically stimulated luminescence (OSL) of Al{sub 2}O{sub 3}:C, principally on the shape of the OSL decay curve and on the OSL sensitivity. The effect of the degree of deep trap filling on the OSL was also studied by monitoring the sensitivity changes after doses of beta irradiation and after step-annealing of samples previously irradiated with high doses. The OSL response to dose shows a linear-supralinear-saturation behavior, with a decrease in the response for doses higher than those required for saturation. This behavior correlates with the sensitivity changes observed in the samples annealed only to 773 K, which show sensitization for doses up to 20-50 Gy and desensitization for higher doses. Data from the step-annealing study leads to the suggestion that the sensitization is caused by the filling of deep electron traps, which become thermally unstable at 1100-1200 K, whereas the desensitization is caused by the filling of deep hole traps, which become thermally unstable at 800-875 K, along with a concomitant decrease in the concentration of recombination centers (F{sup +}-centers). Changes in the shape of the OSL decay curves are also observed at high doses, the decay becoming faster as the dose increases. These changes in the OSL decay curves are discussed in terms of multiple overlapping components, each characterized by different photoionization cross-sections. However, using numerical solutions of the rate equations for a simple model consisting of a main trap and a recombination center, it is shown that the kinetics of OSL process may also be partially responsible for the changes in the OSL curves at high doses in Al{sub 2}O{sub 3}:C. Finally, the implication of these results for the dosimetry of heavy charged particles is discussed.

  8. High resolution sequence stratigraphy in China

    International Nuclear Information System (INIS)

    Zhang Shangfeng; Zhang Changmin; Yin Yanshi; Yin Taiju

    2008-01-01

    Since high resolution sequence stratigraphy was introduced into China by DENG Hong-wen in 1995, it has been experienced two development stages in China which are the beginning stage of theory research and development of theory research and application, and the stage of theoretical maturity and widely application that is going into. It is proved by practices that high resolution sequence stratigraphy plays more and more important roles in the exploration and development of oil and gas in Chinese continental oil-bearing basin and the research field spreads to the exploration of coal mine, uranium mine and other strata deposits. However, the theory of high resolution sequence stratigraphy still has some shortages, it should be improved in many aspects. The authors point out that high resolution sequence stratigraphy should be characterized quantitatively and modelized by computer techniques. (authors)

  9. Development of AMS high resolution injector system

    International Nuclear Information System (INIS)

    Bao Yiwen; Guan Xialing; Hu Yueming

    2008-01-01

    The Beijing HI-13 tandem accelerator AMS high resolution injector system was developed. The high resolution energy achromatic system consists of an electrostatic analyzer and a magnetic analyzer, which mass resolution can reach 600 and transmission is better than 80%. (authors)

  10. Resolution enhancement of low quality videos using a high-resolution frame

    NARCIS (Netherlands)

    Pham, T.Q.; Van Vliet, L.J.; Schutte, K.

    2006-01-01

    This paper proposes an example-based Super-Resolution (SR) algorithm of compressed videos in the Discrete Cosine Transform (DCT) domain. Input to the system is a Low-Resolution (LR) compressed video together with a High-Resolution (HR) still image of similar content. Using a training set of

  11. High resolution, high speed ultrahigh vacuum microscopy

    International Nuclear Information System (INIS)

    Poppa, Helmut

    2004-01-01

    The history and future of transmission electron microscopy (TEM) is discussed as it refers to the eventual development of instruments and techniques applicable to the real time in situ investigation of surface processes with high resolution. To reach this objective, it was necessary to transform conventional high resolution instruments so that an ultrahigh vacuum (UHV) environment at the sample site was created, that access to the sample by various in situ sample modification procedures was provided, and that in situ sample exchanges with other integrated surface analytical systems became possible. Furthermore, high resolution image acquisition systems had to be developed to take advantage of the high speed imaging capabilities of projection imaging microscopes. These changes to conventional electron microscopy and its uses were slowly realized in a few international laboratories over a period of almost 40 years by a relatively small number of researchers crucially interested in advancing the state of the art of electron microscopy and its applications to diverse areas of interest; often concentrating on the nucleation, growth, and properties of thin films on well defined material surfaces. A part of this review is dedicated to the recognition of the major contributions to surface and thin film science by these pioneers. Finally, some of the important current developments in aberration corrected electron optics and eventual adaptations to in situ UHV microscopy are discussed. As a result of all the path breaking developments that have led to today's highly sophisticated UHV-TEM systems, integrated fundamental studies are now possible that combine many traditional surface science approaches. Combined investigations to date have involved in situ and ex situ surface microscopies such as scanning tunneling microscopy/atomic force microscopy, scanning Auger microscopy, and photoemission electron microscopy, and area-integrating techniques such as x-ray photoelectron

  12. A high resolution solar atlas for fluorescence calculations

    Science.gov (United States)

    Hearn, M. F.; Ohlmacher, J. T.; Schleicher, D. G.

    1983-01-01

    The characteristics required of a solar atlas to be used for studying the fluorescence process in comets are examined. Several sources of low resolution data were combined to provide an absolutely calibrated spectrum from 2250 A to 7000A. Three different sources of high resolution data were also used to cover this same spectral range. The low resolution data were then used to put each high resolution spectrum on an absolute scale. The three high resolution spectra were then combined in their overlap regions to produce a single, absolutely calibrated high resolution spectrum over the entire spectral range.

  13. Investigation of OSL signal of resistors from mobile phones for accidental dosimetry

    International Nuclear Information System (INIS)

    Mrozik, A.; Marczewska, B.; Bilski, P.; Gieszczyk, W.

    2014-01-01

    Resistors from mobile phones, usually located near the human body, are considered as individual dosimeters of ionizing radiation in emergency situations. The resistors contain Al 2 O 3 , which is optically stimulated luminescence (OSL) material sensitive to ionizing radiation. This work is focused on determination of dose homogeneity within mobile phones which was carried out by OSL measurements of resistors placed in different parts inside the mobile phone. Separate, commercially available resistors, similar in the shape and size to the resistors from circuit board of the studied mobile phone, were situated in different locations inside it. The irradiations were performed in uniform 60 Co and 137 Cs radiation fields, with the mobile phones connected and not connected to the cellular network. The dose decrease of 9% was measured for original resistors situated between circuit board and battery, in comparison to the dose at the front of the phone. The resistors showed the lower signal when the mobile phone was connected to the cellular network, due to higher temperature inside the housing. The profile of fading was investigated within 3 month period for resistors irradiated with 1 Gy of gamma rays to estimate of the fading coefficient. - Highlights: • Impact of a mobile phone mode (switched on/off) on absorbed dose by resistors was showed. • The influence of the temperature during irradiation on absorbed dose was measured. • Dose distribution inside of a mobile phone was performed. • Fading factor of resistors was calculated

  14. Optically stimulated luminescence (OSL) dating of quartzite cobbles from the Tapada do Montinho archaeological site (east-central Portugal)

    DEFF Research Database (Denmark)

    Sohbati, Reza; Murray, Andrew S.; Buylaert, Jan-Pieter

    2012-01-01

    The burial age of an alluvially deposited cobble pavement at the Tapada do Montinho archaeological site (east-central Portugal) is investigated using optically stimulated luminescence (OSL) dating. Measurements on the cobbles (quartzite clasts) were carried out on intact slices and large aliquots...

  15. OSL-SAR dating of sediments from Brazilian aeolian system: Dama Branca, Rio de Janeiro, morphodynamic study

    Energy Technology Data Exchange (ETDEWEB)

    Carmo, Lucas S. do; Watanabe, Shigueo, E-mail: lsatiro@usp.br, E-mail: lacifid@if.usp.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); DeWitt, Regina, E-mail: dewittr@ecu.edu [East Carolina University (ECU), Greenville, NC (United States)

    2017-07-01

    It has been reported that the formation and stabilization of coastal dune fields in Brazil have a dependence on the climate changes and Relative Sea Level (RSL) variations. A few topics regarding the morphodynamics of coastal aeolian systems in Brazil can be the RSL variations in the Holocene and weather conditions. In this work, a dune field known as 'Dama Branca', located in the town of Cabo Frio, Rio de Janeiro, has been studied to understand its formation and stabilization. Dating by trapped charge dating techniques as Optically Stimulated Luminescence (OSL) using the Single Aliquot Regenerative protocol (SAR), help to understand the formation and dynamics of aeolian systems in Brazil. Samples from a dune were collected from different heights and points for dating. The results obtained by OSL-SAR showed that ages decrease as the height from the dune base increase and older samples are found in deeper horizontal positions. The ages for the base of the studied dunes indicated that its stabilization occurred during the recess of the sea level. (author)

  16. OSL-SAR dating of sediments from Brazilian aeolian system: Dama Branca, Rio de Janeiro, morphodynamic study

    International Nuclear Information System (INIS)

    Carmo, Lucas S. do; Watanabe, Shigueo; DeWitt, Regina

    2017-01-01

    It has been reported that the formation and stabilization of coastal dune fields in Brazil have a dependence on the climate changes and Relative Sea Level (RSL) variations. A few topics regarding the morphodynamics of coastal aeolian systems in Brazil can be the RSL variations in the Holocene and weather conditions. In this work, a dune field known as 'Dama Branca', located in the town of Cabo Frio, Rio de Janeiro, has been studied to understand its formation and stabilization. Dating by trapped charge dating techniques as Optically Stimulated Luminescence (OSL) using the Single Aliquot Regenerative protocol (SAR), help to understand the formation and dynamics of aeolian systems in Brazil. Samples from a dune were collected from different heights and points for dating. The results obtained by OSL-SAR showed that ages decrease as the height from the dune base increase and older samples are found in deeper horizontal positions. The ages for the base of the studied dunes indicated that its stabilization occurred during the recess of the sea level. (author)

  17. Study of sensitivity change of OSL signals from quartz and feldspars as a function of preheat temperature

    DEFF Research Database (Denmark)

    Jungner, H.; Bøtter-Jensen, L.

    1994-01-01

    and as a result, the equivalent dose (ED) would be underestimated. A study of sensitivity changes in feldspars and quartz was carried out with emphasis on the effect of preheat and annealing on the OSL signal. Measurement results obtained are presented, and possible elimination of errors in dating caused...

  18. High-resolution SPECT for small-animal imaging

    International Nuclear Information System (INIS)

    Qi Yujin

    2006-01-01

    This article presents a brief overview of the development of high-resolution SPECT for small-animal imaging. A pinhole collimator has been used for high-resolution animal SPECT to provide better spatial resolution and detection efficiency in comparison with a parallel-hole collimator. The theory of imaging characteristics of the pinhole collimator is presented and the designs of the pinhole aperture are discussed. The detector technologies used for the development of small-animal SPECT and the recent advances are presented. The evolving trend of small-animal SPECT is toward a multi-pinhole and a multi-detector system to obtain a high resolution and also a high detection efficiency. (authors)

  19. Sources of uncertainty in individual monitoring for photographic,TL and OSL dosimetry techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Max S.; Silva, Everton R.; Mauricio, Claudia L.P., E-mail: max.das.ferreira@gmail.com, E-mail: everton@ird.gov.br, E-mail: claudia@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The identification of the uncertainty sources and their quantification is essential to the quality of any dosimetric results. If uncertainties are not stated for all dose measurements informed in the monthly dose report to the monitored radiation facilities, they need to be known. This study aims to analyze the influence of different sources of uncertainties associated with photographic, TL and OSL dosimetric techniques, considering the evaluation of occupational doses of whole-body exposure for photons. To identify the sources of uncertainty it was conducted a bibliographic review in specific documents that deal with operational aspects of each technique and the uncertainties associated to each of them. Withal, technical visits to individual monitoring services were conducted to assist in this identification. The sources of uncertainty were categorized and their contributions were expressed in a qualitative way. The process of calibration and traceability are the most important sources of uncertainties, regardless the technique used. For photographic dosimetry, the remaining important uncertainty sources are due to: energy and angular dependence; linearity of response; variations in the films processing. For TL and OSL, the key process for a good performance is respectively the reproducibility of the thermal and optical cycles. For the three techniques, all procedures of the measurement process must be standardized, controlled and reproducible. Further studies can be performed to quantify the contribution of the sources of uncertainty. (author)

  20. High resolution time integration for SN radiation transport

    International Nuclear Information System (INIS)

    Thoreson, Greg; McClarren, Ryan G.; Chang, Jae H.

    2009-01-01

    First-order, second-order, and high resolution time discretization schemes are implemented and studied for the discrete ordinates (S N ) equations. The high resolution method employs a rate of convergence better than first-order, but also suppresses artificial oscillations introduced by second-order schemes in hyperbolic partial differential equations. The high resolution method achieves these properties by nonlinearly adapting the time stencil to use a first-order method in regions where oscillations could be created. We employ a quasi-linear solution scheme to solve the nonlinear equations that arise from the high resolution method. All three methods were compared for accuracy and convergence rates. For non-absorbing problems, both second-order and high resolution converged to the same solution as the first-order with better convergence rates. High resolution is more accurate than first-order and matches or exceeds the second-order method

  1. High tracking resolution detectors. Final Technical Report

    International Nuclear Information System (INIS)

    Vasile, Stefan; Li, Zheng

    2010-01-01

    High-resolution tracking detectors based on Active Pixel Sensor (APS) have been valuable tools in Nuclear Physics and High-Energy Physics research, and have contributed to major discoveries. Their integration time, radiation length and readout rate is a limiting factor for the planed luminosity upgrades in nuclear and high-energy physics collider-based experiments. The goal of this program was to demonstrate and develop high-gain, high-resolution tracking detector arrays with faster readout, and shorter radiation length than APS arrays. These arrays may operate as direct charged particle detectors or as readouts of high resolution scintillating fiber arrays. During this program, we developed in CMOS large, high-resolution pixel sensor arrays with integrated readout, and reset at pixel level. Their intrinsic gain, high immunity to surface and moisture damage, will allow operating these detectors with minimal packaging/passivation requirements and will result in radiation length superior to APS. In Phase I, we designed and fabricated arrays with calorimetric output capable of sub-pixel resolution and sub-microsecond readout rate. The technical effort was dedicated to detector and readout structure development, performance verification, as well as to radiation damage and damage annealing.

  2. Ultra high resolution tomography

    Energy Technology Data Exchange (ETDEWEB)

    Haddad, W.S.

    1994-11-15

    Recent work and results on ultra high resolution three dimensional imaging with soft x-rays will be presented. This work is aimed at determining microscopic three dimensional structure of biological and material specimens. Three dimensional reconstructed images of a microscopic test object will be presented; the reconstruction has a resolution on the order of 1000 A in all three dimensions. Preliminary work with biological samples will also be shown, and the experimental and numerical methods used will be discussed.

  3. A high resolution portable spectroscopy system

    International Nuclear Information System (INIS)

    Kulkarni, C.P.; Vaidya, P.P.; Paulson, M.; Bhatnagar, P.V.; Pande, S.S.; Padmini, S.

    2003-01-01

    Full text: This paper describes the system details of a High Resolution Portable Spectroscopy System (HRPSS) developed at Electronics Division, BARC. The system can be used for laboratory class, high-resolution nuclear spectroscopy applications. The HRPSS consists of a specially designed compact NIM bin, with built-in power supplies, accommodating a low power, high resolution MCA, and on-board embedded computer for spectrum building and communication. A NIM based spectroscopy amplifier and a HV module for detector bias are integrated (plug-in) in the bin. The system communicates with a host PC via a serial link. Along-with a laptop PC, and a portable HP-Ge detector, the HRPSS offers a laboratory class performance for portable applications

  4. High Resolution Elevation Contours

    Data.gov (United States)

    Minnesota Department of Natural Resources — This dataset contains contours generated from high resolution data sources such as LiDAR. Generally speaking this data is 2 foot or less contour interval.

  5. Extension of least squares spectral resolution algorithm to high-resolution lipidomics data

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Ying-Xu [Department of Chemistry, University of Bergen, PO Box 7803, N-5020 Bergen (Norway); Mjøs, Svein Are, E-mail: svein.mjos@kj.uib.no [Department of Chemistry, University of Bergen, PO Box 7803, N-5020 Bergen (Norway); David, Fabrice P.A. [Bioinformatics and Biostatistics Core Facility, School of Life Sciences, Ecole Polytechnique Fédérale de Lausanne (EPFL) and Swiss Institute of Bioinformatics (SIB), Lausanne (Switzerland); Schmid, Adrien W. [Proteomics Core Facility, Ecole Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne (Switzerland)

    2016-03-31

    Lipidomics, which focuses on the global study of molecular lipids in biological systems, has been driven tremendously by technical advances in mass spectrometry (MS) instrumentation, particularly high-resolution MS. This requires powerful computational tools that handle the high-throughput lipidomics data analysis. To address this issue, a novel computational tool has been developed for the analysis of high-resolution MS data, including the data pretreatment, visualization, automated identification, deconvolution and quantification of lipid species. The algorithm features the customized generation of a lipid compound library and mass spectral library, which covers the major lipid classes such as glycerolipids, glycerophospholipids and sphingolipids. Next, the algorithm performs least squares resolution of spectra and chromatograms based on the theoretical isotope distribution of molecular ions, which enables automated identification and quantification of molecular lipid species. Currently, this methodology supports analysis of both high and low resolution MS as well as liquid chromatography-MS (LC-MS) lipidomics data. The flexibility of the methodology allows it to be expanded to support more lipid classes and more data interpretation functions, making it a promising tool in lipidomic data analysis. - Highlights: • A flexible strategy for analyzing MS and LC-MS data of lipid molecules is proposed. • Isotope distribution spectra of theoretically possible compounds were generated. • High resolution MS and LC-MS data were resolved by least squares spectral resolution. • The method proposed compounds that are likely to occur in the analyzed samples. • The proposed compounds matched results from manual interpretation of fragment spectra.

  6. Extension of least squares spectral resolution algorithm to high-resolution lipidomics data

    International Nuclear Information System (INIS)

    Zeng, Ying-Xu; Mjøs, Svein Are; David, Fabrice P.A.; Schmid, Adrien W.

    2016-01-01

    Lipidomics, which focuses on the global study of molecular lipids in biological systems, has been driven tremendously by technical advances in mass spectrometry (MS) instrumentation, particularly high-resolution MS. This requires powerful computational tools that handle the high-throughput lipidomics data analysis. To address this issue, a novel computational tool has been developed for the analysis of high-resolution MS data, including the data pretreatment, visualization, automated identification, deconvolution and quantification of lipid species. The algorithm features the customized generation of a lipid compound library and mass spectral library, which covers the major lipid classes such as glycerolipids, glycerophospholipids and sphingolipids. Next, the algorithm performs least squares resolution of spectra and chromatograms based on the theoretical isotope distribution of molecular ions, which enables automated identification and quantification of molecular lipid species. Currently, this methodology supports analysis of both high and low resolution MS as well as liquid chromatography-MS (LC-MS) lipidomics data. The flexibility of the methodology allows it to be expanded to support more lipid classes and more data interpretation functions, making it a promising tool in lipidomic data analysis. - Highlights: • A flexible strategy for analyzing MS and LC-MS data of lipid molecules is proposed. • Isotope distribution spectra of theoretically possible compounds were generated. • High resolution MS and LC-MS data were resolved by least squares spectral resolution. • The method proposed compounds that are likely to occur in the analyzed samples. • The proposed compounds matched results from manual interpretation of fragment spectra.

  7. Reliability of equivalent-dose determination and age-models in the OSL dating of historical and modern palaeoflood sediments

    DEFF Research Database (Denmark)

    Medialdea, Alicia; Thomsen, Kristina Jørkov; Murray, Andrew Sean

    2014-01-01

    model to small aliquot (similar to 30 grains) dose distributions. From our study we conclude that these and similar young slack-water flood deposits can be accurately dated using quartz OSL, opening up the possibility of establishing time series of flood discharge in catchments for which no instrumental...

  8. Ultra-high resolution coded wavefront sensor

    KAUST Repository

    Wang, Congli

    2017-06-08

    Wavefront sensors and more general phase retrieval methods have recently attracted a lot of attention in a host of application domains, ranging from astronomy to scientific imaging and microscopy. In this paper, we introduce a new class of sensor, the Coded Wavefront Sensor, which provides high spatio-temporal resolution using a simple masked sensor under white light illumination. Specifically, we demonstrate megapixel spatial resolution and phase accuracy better than 0.1 wavelengths at reconstruction rates of 50 Hz or more, thus opening up many new applications from high-resolution adaptive optics to real-time phase retrieval in microscopy.

  9. High resolution data acquisition

    Science.gov (United States)

    Thornton, Glenn W.; Fuller, Kenneth R.

    1993-01-01

    A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock (38) pulse train (37) and analog circuitry (44) for generating a triangular wave (46) synchronously with the pulse train (37). The triangular wave (46) has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter (18, 32) forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter (26) counts the clock pulse train (37) during the interval to form a gross event interval time. A computer (52) then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.

  10. High resolution time integration for Sn radiation transport

    International Nuclear Information System (INIS)

    Thoreson, Greg; McClarren, Ryan G.; Chang, Jae H.

    2008-01-01

    First order, second order and high resolution time discretization schemes are implemented and studied for the S n equations. The high resolution method employs a rate of convergence better than first order, but also suppresses artificial oscillations introduced by second order schemes in hyperbolic differential equations. All three methods were compared for accuracy and convergence rates. For non-absorbing problems, both second order and high resolution converged to the same solution as the first order with better convergence rates. High resolution is more accurate than first order and matches or exceeds the second order method. (authors)

  11. Structure of high-resolution NMR spectra

    CERN Document Server

    Corio, PL

    2012-01-01

    Structure of High-Resolution NMR Spectra provides the principles, theories, and mathematical and physical concepts of high-resolution nuclear magnetic resonance spectra.The book presents the elementary theory of magnetic resonance; the quantum mechanical theory of angular momentum; the general theory of steady state spectra; and multiple quantum transitions, double resonance and spin echo experiments.Physicists, chemists, and researchers will find the book a valuable reference text.

  12. High-resolution multi-slice PET

    International Nuclear Information System (INIS)

    Yasillo, N.J.; Chintu Chen; Ordonez, C.E.; Kapp, O.H.; Sosnowski, J.; Beck, R.N.

    1992-01-01

    This report evaluates the progress to test the feasibility and to initiate the design of a high resolution multi-slice PET system. The following specific areas were evaluated: detector development and testing; electronics configuration and design; mechanical design; and system simulation. The design and construction of a multiple-slice, high-resolution positron tomograph will provide substantial improvements in the accuracy and reproducibility of measurements of the distribution of activity concentrations in the brain. The range of functional brain research and our understanding of local brain function will be greatly extended when the development of this instrumentation is completed

  13. High resolution NMR spectroscopy of synthetic polymers in bulk

    International Nuclear Information System (INIS)

    Komorski, R.A.

    1986-01-01

    The contents of this book are: Overview of high-resolution NMR of solid polymers; High-resolution NMR of glassy amorphous polymers; Carbon-13 solid-state NMR of semicrystalline polymers; Conformational analysis of polymers of solid-state NMR; High-resolution NMR studies of oriented polymers; High-resolution solid-state NMR of protons in polymers; and Deuterium NMR of solid polymers. This work brings together the various approaches for high-resolution NMR studies of bulk polymers into one volume. Heavy emphasis is, of course, given to 13C NMR studies both above and below Tg. Standard high-power pulse and wide-line techniques are not covered

  14. Quartz OSL dating of late quaternary Chinese and Serbian loess: A cross Eurasian comparison of dust mass accumulation rates

    DEFF Research Database (Denmark)

    Peric, Zoran; Adolphi, Emma Lagerbäck; Stevens, Thomas

    2018-01-01

    on multi-millennial timescales, with no detailed examination of dust MAR at the two ends of the Eurasian loess belt on shorter, sub-orbital scales. Here we present a detailed quartz optically stimulated luminescence (OSL) chronology from the Serbian Titel Loess Plateau (Veliki Surduk loess core...

  15. High resolution integral holography using Fourier ptychographic approach.

    Science.gov (United States)

    Li, Zhaohui; Zhang, Jianqi; Wang, Xiaorui; Liu, Delian

    2014-12-29

    An innovative approach is proposed for calculating high resolution computer generated integral holograms by using the Fourier Ptychographic (FP) algorithm. The approach initializes a high resolution complex hologram with a random guess, and then stitches together low resolution multi-view images, synthesized from the elemental images captured by integral imaging (II), to recover the high resolution hologram through an iterative retrieval with FP constrains. This paper begins with an analysis of the principle of hologram synthesis from multi-projections, followed by an accurate determination of the constrains required in the Fourier ptychographic integral-holography (FPIH). Next, the procedure of the approach is described in detail. Finally, optical reconstructions are performed and the results are demonstrated. Theoretical analysis and experiments show that our proposed approach can reconstruct 3D scenes with high resolution.

  16. High-spatial resolution and high-spectral resolution detector for use in the measurement of solar flare hard x rays

    International Nuclear Information System (INIS)

    Desai, U.D.; Orwig, L.E.

    1988-01-01

    In the areas of high spatial resolution, the evaluation of a hard X-ray detector with 65 micron spatial resolution for operation in the energy range from 30 to 400 keV is proposed. The basic detector is a thick large-area scintillator faceplate, composed of a matrix of high-density scintillating glass fibers, attached to a proximity type image intensifier tube with a resistive-anode digital readout system. Such a detector, combined with a coded-aperture mask, would be ideal for use as a modest-sized hard X-ray imaging instrument up to X-ray energies as high as several hundred keV. As an integral part of this study it was also proposed that several techniques be critically evaluated for X-ray image coding which could be used with this detector. In the area of high spectral resolution, it is proposed to evaluate two different types of detectors for use as X-ray spectrometers for solar flares: planar silicon detectors and high-purity germanium detectors (HPGe). Instruments utilizing these high-spatial-resolution detectors for hard X-ray imaging measurements from 30 to 400 keV and high-spectral-resolution detectors for measurements over a similar energy range would be ideally suited for making crucial solar flare observations during the upcoming maximum in the solar cycle

  17. High resolution photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Arko, A.J.

    1988-01-01

    Photoelectron Spectroscopy (PES) covers a very broad range of measurements, disciplines, and interests. As the next generation light source, the FEL will result in improvements over the undulator that are larger than the undulater improvements over bending magnets. The combination of high flux and high inherent resolution will result in several orders of magnitude gain in signal to noise over measurements using synchrotron-based undulators. The latter still require monochromators. Their resolution is invariably strongly energy-dependent so that in the regions of interest for many experiments (h upsilon > 100 eV) they will not have a resolving power much over 1000. In order to study some of the interesting phenomena in actinides (heavy fermions e.g.) one would need resolving powers of 10 4 to 10 5 . These values are only reachable with the FEL

  18. Preliminary results of chronostratigraphic field work, OSL-dating and morphogenetic reconstruction of an alluvial apron at Alborz southern foothill, Damghan basin, Iran

    Science.gov (United States)

    Büdel, Christian; Fuchs, Markus; Majid Padashi, Seyed; Baumhauer, Roland

    2014-05-01

    Here we present preliminary results of a chronostratigraphic study of an alluvial fan in the Damghan Basin, northern Iran. The basin sediments date back to the Mio- and Pliocene and therefore represent the starting point of alluvial fan aggradation. Today, the still active alluvial fans prograde from the Albors Mountain ranges and sit on the older sediment bodies. In this study, our focus is on the late Pleistocene to Holocene alluvial fan sedimentation history. The upper stratigraphy of the alluvial fans and intercalated lake deposits is characterized by six individual layers of gravels and fines, representing six different stratigraphic units. These units are described and classified by detailed geomorphological and stratigraphic mapping. To establish an alluvial fan chronology, six profiles were sampled for OSL dating. As expected, due to the high-energy transport system of alluvial fan aggradation in semi-desert environments, OSL dating of these sediments is challenging due to the problem of insufficient bleaching. Consequently, most of the samples are interpreted as maximum ages. However, the measurements show a consistent internal age structure and the overall OSL-based chronology is in agreement with the age model derived from our geomorphological analysis. As a first interpretation, based on surveyed geomorphological features and chronological analysis, we could identify seven morphodynamic phases, leading to a genetic model of alluvial fan aggradation. The oldest Pleistocene age estimate is derived from a former lake terrace. The following ages represent ongoing lake sediment deposition and the development of a proximal and mid-fan gravel cover. After the youngest lake deposits were accumulated within the Holocene, the lake starts to retreat and small alluvial fans are filling up the former lake bottom. This last sedimentation phase can be divided in at least two sub-phases, probably coupled to a lateral shifting of the active depositional lobe and to the

  19. Comparison of Cottonwood Dendrochronology and Optically Stimulated Luminescence Geochronometers Along a High Plains Meandering River, Powder River, Montana, USA

    Science.gov (United States)

    Hasse, T. R.; Schook, D. M.

    2017-12-01

    Geochronometers at centennial scales can aid our understanding of process rates in fluvial geomorphology. Plains cottonwood trees (Populus deltoides ssp. Monilifera) in the high plains of the United States are known to germinate on freshly created deposits such as point bars adjacent to rivers. As the trees mature they may be partially buried (up to a few meters) by additional flood deposits. Cottonwood age gives a minimum age estimate of the stratigraphic surface where the tree germinated and a maximum age estimate for overlying sediments, providing quantitative data on rates of river migration and sediment accumulation. Optically Stimulated Luminescence (OSL) of sand grains can be used to estimate the time since the sand grains were last exposed to sunlight, also giving a minimum age estimate of sediment burial. Both methods have disadvantages: Browsing, partial burial, and other damage to young cottonwoods can increase the time required for the tree to reach a height where it can be sampled with a tree corer, making the germination point a few years to a few decades older than the measured tree age; fluvial OSL samples can have inherited age (when the OSL age is older than the burial age) if the sediment was not completely bleached prior to burial. We collected OSL samples at 8 eroding banks of the Powder River Montana, and tree cores at breast height (±1.2 m) from cottonwood trees growing on the floodplain adjacent to the OSL sample locations. Using the Minimum Age Model (MAM) we found that OSL ages appear to be 500 to 1,000 years older than the adjacent cottonwood trees which range in age (at breast height) from 60 to 185 years. Three explanations for this apparent anomaly in ages are explored. Samples for OSL could be below a stratigraphic unconformity relative to the cottonwood germination elevation. Shallow samples for OSL could be affected by anthropogenic mixing of sediments due to plowing and leveling of hay fields. The OSL samples could have

  20. Dosimetry of Al2O3 optically stimulated luminescent dosimeter at high energy photons and electrons

    Science.gov (United States)

    Yusof, M. F. Mohd; Joohari, N. A.; Abdullah, R.; Shukor, N. S. Abd; Kadir, A. B. Abd; Isa, N. Mohd

    2018-01-01

    The linearity of Al2O3 OSL dosimeters (OSLD) were evaluated for dosimetry works in clinical photons and electrons. The measurements were made at a reference depth of Zref according to IAEA TRS 398:2000 codes of practice at 6 and 10 MV photons and 6 and 9 MeV electrons. The measured dose was compared to the thermoluminescence dosimeters (TLD) and ionization chamber commonly used for dosimetry works for higher energy photons and electrons. The results showed that the measured dose in OSL dosimeters were in good agreement with the reported by the ionization chamber in both high energy photons and electrons. A reproducibility test also reported excellent consistency of readings with the OSL at similar energy levels. The overall results confirmed the suitability of OSL dosimeters for dosimetry works involving high energy photons and electrons in radiotherapy.

  1. Bioactivity characterization of 45S5 bioglass using TL, OSL and EPR: Comparison with the case of 58S sol-gel bioactive glass

    Energy Technology Data Exchange (ETDEWEB)

    Polymeris, G.S., E-mail: gspolymeris@ankara.edu.tr [Ankara University, Institute of Nuclear Sciences, 06100 Beşevler, Ankara (Turkey); Giannoulatou, V. [Ankara University, Institute of Nuclear Sciences, 06100 Beşevler, Ankara (Turkey); Solid State Section, Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Kyriakidou, A. [Solid State Section, Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Sfampa, I.K. [Nuclear Physics Laboratory, Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Theodorou, G.S. [Solid State Section, Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Şahiner, E.; Meriç, N. [Ankara University, Institute of Nuclear Sciences, 06100 Beşevler, Ankara (Turkey); Kitis, G. [Nuclear Physics Laboratory, Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Paraskevopoulos, K.M. [Solid State Section, Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece)

    2017-01-01

    The current work exploits the effective application of thermoluminescence (TL), optically stimulated luminescence (OSL) and the possibility of applying Electron Paramagnetic Resonance (EPR) for the discrimination between different bioactive responses in the case of the 45S5 bioactive glass (SiO{sub 2} 45, Na{sub 2}O 24.5, CaO 24.5, P{sub 2}O{sub 5} 6 in wt%), which was synthesized through melting process. These techniques are suggested mainly due to their low spectroscopic detection thresholds. The original 45S5 in grain size range of 20–40 μm was immersed in the Simulated Body Fluid (SBF) for various different immersion times ranging over one week. In this work the 110 °C TL peak, a specific OSL component and the EPR signal at g = 2.013 ascribed to oxygen hole center (OHC) are used due to their sensitivity to the different bioactive responses. For all luminescence and EPR components, the intensity plot versus immersion time yields sharp discontinuities, resulting in effective probes regarding the timescale for both the beginning as well as the end of the procedure of the crystalline HCAp formation respectively. On the contrary to the smooth decreasing pattern of both luminescence entities, the peak to peak amplitude of the EPR signal indicates an initial increase for the initial 16 min of immersion, followed by a further decrease throughout the immersion time duration. The discontinuities monitored for both sensitivity of TL, OSL and EPR, in conjunction with the discontinuities monitored for the sensitization of TL and OSL, when plotted versus immersion time, provide an individual time scale for each one of the chemical reactions involved in the five steps of the aforementioned procedure. According to the authors' best knowledge, scarce characterization techniques could provide this time scale frame, while it is the first time that such an application of OSL and EPR is attempted. Finally, the bioactive response of the 45S5 bioglass was compared with that

  2. High-resolution regional climate model evaluation using variable-resolution CESM over California

    Science.gov (United States)

    Huang, X.; Rhoades, A.; Ullrich, P. A.; Zarzycki, C. M.

    2015-12-01

    Understanding the effect of climate change at regional scales remains a topic of intensive research. Though computational constraints remain a problem, high horizontal resolution is needed to represent topographic forcing, which is a significant driver of local climate variability. Although regional climate models (RCMs) have traditionally been used at these scales, variable-resolution global climate models (VRGCMs) have recently arisen as an alternative for studying regional weather and climate allowing two-way interaction between these domains without the need for nudging. In this study, the recently developed variable-resolution option within the Community Earth System Model (CESM) is assessed for long-term regional climate modeling over California. Our variable-resolution simulations will focus on relatively high resolutions for climate assessment, namely 28km and 14km regional resolution, which are much more typical for dynamically downscaled studies. For comparison with the more widely used RCM method, the Weather Research and Forecasting (WRF) model will be used for simulations at 27km and 9km. All simulations use the AMIP (Atmospheric Model Intercomparison Project) protocols. The time period is from 1979-01-01 to 2005-12-31 (UTC), and year 1979 was discarded as spin up time. The mean climatology across California's diverse climate zones, including temperature and precipitation, is analyzed and contrasted with the Weather Research and Forcasting (WRF) model (as a traditional RCM), regional reanalysis, gridded observational datasets and uniform high-resolution CESM at 0.25 degree with the finite volume (FV) dynamical core. The results show that variable-resolution CESM is competitive in representing regional climatology on both annual and seasonal time scales. This assessment adds value to the use of VRGCMs for projecting climate change over the coming century and improve our understanding of both past and future regional climate related to fine

  3. Section on High Resolution Optical Imaging (HROI)

    Data.gov (United States)

    Federal Laboratory Consortium — The Section on High Resolution Optical Imaging (HROI) develops novel technologies for studying biological processes at unprecedented speed and resolution. Research...

  4. Comparative study of different Al_2O_3:C dosimeters using OSL technique for dosimetry on Volumetric Modulated Arc Radiotherapy Treatment (VMAT)

    International Nuclear Information System (INIS)

    Villani, Daniel; Campos, LetIcia L.; Mancini, Anselmo; Haddad, Cecilia M.K.

    2016-01-01

    In modern radiotherapy, the VMAT technique has become a successful treatment alternative. Due to its complexity, a quality assurance program must be established by evaluating, among other items, the dosimetric factors. This paper aims to compare the performance between the OSL aluminum oxide (Al_2O_3:C) nanoDot™ dosimeters (Inlight™ system) manufactured by Landauer Inc. and TLD-500 Al_2O_3:C dosimeters manufactured by Rexon™ for VMAT dosimetry using an anthropomorphic phantom. The results showed that both type of Al_2O_3:C dosimeters presented good repeatability and agreement between the doses measured and calculated by planning system. However, the need of sophisticated readers to OSL analysis of the TLD-500, turns it less practical for routine usage, comparing to Inlight™ system. (author)

  5. High angular resolution at LBT

    Science.gov (United States)

    Conrad, A.; Arcidiacono, C.; Bertero, M.; Boccacci, P.; Davies, A. G.; Defrere, D.; de Kleer, K.; De Pater, I.; Hinz, P.; Hofmann, K. H.; La Camera, A.; Leisenring, J.; Kürster, M.; Rathbun, J. A.; Schertl, D.; Skemer, A.; Skrutskie, M.; Spencer, J. R.; Veillet, C.; Weigelt, G.; Woodward, C. E.

    2015-12-01

    High angular resolution from ground-based observatories stands as a key technology for advancing planetary science. In the window between the angular resolution achievable with 8-10 meter class telescopes, and the 23-to-40 meter giants of the future, LBT provides a glimpse of what the next generation of instruments providing higher angular resolution will provide. We present first ever resolved images of an Io eruption site taken from the ground, images of Io's Loki Patera taken with Fizeau imaging at the 22.8 meter LBT [Conrad, et al., AJ, 2015]. We will also present preliminary analysis of two data sets acquired during the 2015 opposition: L-band fringes at Kurdalagon and an occultation of Loki and Pele by Europa (see figure). The light curves from this occultation will yield an order of magnitude improvement in spatial resolution along the path of ingress and egress. We will conclude by providing an overview of the overall benefit of recent and future advances in angular resolution for planetary science.

  6. A method for generating high resolution satellite image time series

    Science.gov (United States)

    Guo, Tao

    2014-10-01

    There is an increasing demand for satellite remote sensing data with both high spatial and temporal resolution in many applications. But it still is a challenge to simultaneously improve spatial resolution and temporal frequency due to the technical limits of current satellite observation systems. To this end, much R&D efforts have been ongoing for years and lead to some successes roughly in two aspects, one includes super resolution, pan-sharpen etc. methods which can effectively enhance the spatial resolution and generate good visual effects, but hardly preserve spectral signatures and result in inadequate analytical value, on the other hand, time interpolation is a straight forward method to increase temporal frequency, however it increase little informative contents in fact. In this paper we presented a novel method to simulate high resolution time series data by combing low resolution time series data and a very small number of high resolution data only. Our method starts with a pair of high and low resolution data set, and then a spatial registration is done by introducing LDA model to map high and low resolution pixels correspondingly. Afterwards, temporal change information is captured through a comparison of low resolution time series data, and then projected onto the high resolution data plane and assigned to each high resolution pixel according to the predefined temporal change patterns of each type of ground objects. Finally the simulated high resolution data is generated. A preliminary experiment shows that our method can simulate a high resolution data with a reasonable accuracy. The contribution of our method is to enable timely monitoring of temporal changes through analysis of time sequence of low resolution images only, and usage of costly high resolution data can be reduces as much as possible, and it presents a highly effective way to build up an economically operational monitoring solution for agriculture, forest, land use investigation

  7. TL-OSL study of Li{sub 3}PO{sub 4}: Mg, Cu phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Rahangdale, S. R., E-mail: sachin.rahangdale1@gmail.com; Wankhede, S. P. [Department of Physics, K.D.K.College of Engineering, Nagpur (India); Dhabekar, B. S. [RPAD, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Palikundwar, U. A.; Moharil, S. V. [Department of Physics, RTM Nagpur University, Nagpur, 440010 (India)

    2015-08-28

    In the present work, we report the thermoluminescence and optically stimulated luminescence properties of Mg and Cu doped Li{sub 3}PO{sub 4} phosphor. The phosphor was synthesized by precipitation method. The thermoluminescence dosimetric peak temperature for the phosphor varies with concentrations of Mg and Cu. Li{sub 3}PO{sub 4} shows good response to 470nm optical stimulation. The OSL sensitivity of the phosphor is approximately 12 times than that of standard Lithium magnesium phosphate. This study may help to develop this material for the application in real time dosimetry using optically stimulated luminescence.

  8. Resolution enhancement of low-quality videos using a high-resolution frame

    Science.gov (United States)

    Pham, Tuan Q.; van Vliet, Lucas J.; Schutte, Klamer

    2006-01-01

    This paper proposes an example-based Super-Resolution (SR) algorithm of compressed videos in the Discrete Cosine Transform (DCT) domain. Input to the system is a Low-Resolution (LR) compressed video together with a High-Resolution (HR) still image of similar content. Using a training set of corresponding LR-HR pairs of image patches from the HR still image, high-frequency details are transferred from the HR source to the LR video. The DCT-domain algorithm is much faster than example-based SR in spatial domain 6 because of a reduction in search dimensionality, which is a direct result of the compact and uncorrelated DCT representation. Fast searching techniques like tree-structure vector quantization 16 and coherence search1 are also key to the improved efficiency. Preliminary results on MJPEG sequence show promising result of the DCT-domain SR synthesis approach.

  9. A cloud mask methodology for high resolution remote sensing data combining information from high and medium resolution optical sensors

    Science.gov (United States)

    Sedano, Fernando; Kempeneers, Pieter; Strobl, Peter; Kucera, Jan; Vogt, Peter; Seebach, Lucia; San-Miguel-Ayanz, Jesús

    2011-09-01

    This study presents a novel cloud masking approach for high resolution remote sensing images in the context of land cover mapping. As an advantage to traditional methods, the approach does not rely on thermal bands and it is applicable to images from most high resolution earth observation remote sensing sensors. The methodology couples pixel-based seed identification and object-based region growing. The seed identification stage relies on pixel value comparison between high resolution images and cloud free composites at lower spatial resolution from almost simultaneously acquired dates. The methodology was tested taking SPOT4-HRVIR, SPOT5-HRG and IRS-LISS III as high resolution images and cloud free MODIS composites as reference images. The selected scenes included a wide range of cloud types and surface features. The resulting cloud masks were evaluated through visual comparison. They were also compared with ad-hoc independently generated cloud masks and with the automatic cloud cover assessment algorithm (ACCA). In general the results showed an agreement in detected clouds higher than 95% for clouds larger than 50 ha. The approach produced consistent results identifying and mapping clouds of different type and size over various land surfaces including natural vegetation, agriculture land, built-up areas, water bodies and snow.

  10. High-Resolution Mass Spectrometers

    Science.gov (United States)

    Marshall, Alan G.; Hendrickson, Christopher L.

    2008-07-01

    Over the past decade, mass spectrometry has been revolutionized by access to instruments of increasingly high mass-resolving power. For small molecules up to ˜400 Da (e.g., drugs, metabolites, and various natural organic mixtures ranging from foods to petroleum), it is possible to determine elemental compositions (CcHhNnOoSsPp…) of thousands of chemical components simultaneously from accurate mass measurements (the same can be done up to 1000 Da if additional information is included). At higher mass, it becomes possible to identify proteins (including posttranslational modifications) from proteolytic peptides, as well as lipids, glycoconjugates, and other biological components. At even higher mass (˜100,000 Da or higher), it is possible to characterize posttranslational modifications of intact proteins and to map the binding surfaces of large biomolecule complexes. Here we review the principles and techniques of the highest-resolution analytical mass spectrometers (time-of-flight and Fourier transform ion cyclotron resonance and orbitrap mass analyzers) and describe some representative high-resolution applications.

  11. Comparative study of different Al{sub 2}O{sub 3}:C dosimeters using OSL technique for dosimetry on Volumetric Modulated Arc Radiotherapy Treatment (VMAT); Estudo comparativo de diferentes dosimetros de Al{sub 2}O{sub 3}:C pela tecnica OSL na dosimetria de tratamentos Radioterapicos por Arco Modulado Volumetrico (VMAT)

    Energy Technology Data Exchange (ETDEWEB)

    Villani, Daniel; Campos, LetIcia L., E-mail: dvillani@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Mancini, Anselmo; Haddad, Cecilia M.K. [Hospital Sirio-Libanes, Sao Paulo, SP (Brazil). Centro de Radioterapia

    2016-07-01

    In modern radiotherapy, the VMAT technique has become a successful treatment alternative. Due to its complexity, a quality assurance program must be established by evaluating, among other items, the dosimetric factors. This paper aims to compare the performance between the OSL aluminum oxide (Al{sub 2}O{sub 3}:C) nanoDot™ dosimeters (Inlight™ system) manufactured by Landauer Inc. and TLD-500 Al{sub 2}O{sub 3}:C dosimeters manufactured by Rexon™ for VMAT dosimetry using an anthropomorphic phantom. The results showed that both type of Al{sub 2}O{sub 3}:C dosimeters presented good repeatability and agreement between the doses measured and calculated by planning system. However, the need of sophisticated readers to OSL analysis of the TLD-500, turns it less practical for routine usage, comparing to Inlight™ system. (author)

  12. USGS High Resolution Orthoimagery Collection - Historical - National Geospatial Data Asset (NGDA) High Resolution Orthoimagery

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — USGS high resolution orthorectified images from The National Map combine the image characteristics of an aerial photograph with the geometric qualities of a map. An...

  13. High throughput screening of ligand binding to macromolecules using high resolution powder diffraction

    Science.gov (United States)

    Von Dreele, Robert B.; D'Amico, Kevin

    2006-10-31

    A process is provided for the high throughput screening of binding of ligands to macromolecules using high resolution powder diffraction data including producing a first sample slurry of a selected polycrystalline macromolecule material and a solvent, producing a second sample slurry of a selected polycrystalline macromolecule material, one or more ligands and the solvent, obtaining a high resolution powder diffraction pattern on each of said first sample slurry and the second sample slurry, and, comparing the high resolution powder diffraction pattern of the first sample slurry and the high resolution powder diffraction pattern of the second sample slurry whereby a difference in the high resolution powder diffraction patterns of the first sample slurry and the second sample slurry provides a positive indication for the formation of a complex between the selected polycrystalline macromolecule material and at least one of the one or more ligands.

  14. Texton-based super-resolution for achieving high spatiotemporal resolution in hybrid camera system

    Science.gov (United States)

    Kamimura, Kenji; Tsumura, Norimichi; Nakaguchi, Toshiya; Miyake, Yoichi

    2010-05-01

    Many super-resolution methods have been proposed to enhance the spatial resolution of images by using iteration and multiple input images. In a previous paper, we proposed the example-based super-resolution method to enhance an image through pixel-based texton substitution to reduce the computational cost. In this method, however, we only considered the enhancement of a texture image. In this study, we modified this texton substitution method for a hybrid camera to reduce the required bandwidth of a high-resolution video camera. We applied our algorithm to pairs of high- and low-spatiotemporal-resolution videos, which were synthesized to simulate a hybrid camera. The result showed that the fine detail of the low-resolution video can be reproduced compared with bicubic interpolation and the required bandwidth could be reduced to about 1/5 in a video camera. It was also shown that the peak signal-to-noise ratios (PSNRs) of the images improved by about 6 dB in a trained frame and by 1.0-1.5 dB in a test frame, as determined by comparison with the processed image using bicubic interpolation, and the average PSNRs were higher than those obtained by the well-known Freeman’s patch-based super-resolution method. Compared with that of the Freeman’s patch-based super-resolution method, the computational time of our method was reduced to almost 1/10.

  15. Immersion Gratings for Infrared High-resolution Spectroscopy

    Science.gov (United States)

    Sarugaku, Yuki; Ikeda, Yuji; Kobayashi, Naoto; Kaji, Sayumi; Sukegawa, Takashi; Sugiyama, Shigeru; Nakagawa, Takao; Arasaki, Takayuki; Kondo, Sohei; Nakanishi, Kenshi; Yasui, Chikako; Kawakita, Hideyo

    2016-10-01

    High-resolution spectroscopy in the infrared wavelength range is essential for observations of minor isotopologues, such as HDO for water, and prebiotic organic molecules like hydrocarbons/P-bearing molecules because numerous vibrational molecular bands (including non-polar molecules) are located in this wavelength range. High spectral resolution enables us to detect weak lines without spectral line confusion. This technique has been widely used in planetary sciences, e.g., cometary coma (H2O, CO, and organic molecules), the martian atmosphere (CH4, CO2, H2O and HDO), and the upper atmosphere of gas giants (H3+ and organic molecules such as C2H6). Spectrographs with higher resolution (and higher sensitivity) still have a potential to provide a plenty of findings. However, because the size of spectrographs scales with the spectral resolution, it is difficult to realize it.Immersion grating (IG), which is a diffraction grating wherein the diffraction surface is immersed in a material with a high refractive index (n > 2), provides n times higher spectral resolution compared to a reflective grating of the same size. Because IG reduces the size of spectrograph to 1/n compared to the spectrograph with the same spectral resolution using a conventional reflective grating, it is widely acknowledged as a key optical device to realize compact spectrographs with high spectral resolution.Recently, we succeeded in fabricating a CdZnTe immersion grating with the theoretically predicted diffraction efficiency by machining process using an ultrahigh-precision five-axis processing machine developed by Canon Inc. Using the same technique, we completed a practical germanium (Ge) immersion grating with both a reflection coating on the grating surface and the an AR coating on the entrance surface. It is noteworthy that the wide wavelength range from 2 to 20 um can be covered by the two immersion gratings.In this paper, we present the performances and the applications of the immersion

  16. High resolution tomographic instrument development

    International Nuclear Information System (INIS)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational

  17. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  18. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  19. Comparison of single-grain and small-aliquot OSL dose estimates in < 3000 years old river sediments from South India

    DEFF Research Database (Denmark)

    Thomas, P.J.; Jain, M.; Juyal, N.

    2005-01-01

    We report on OSL dose distributions derived from small-aliquot and single grains of quartz in young fluvial sediments sampled from the Penner River basin, South India. The single-grain dose distributions suggest that 13 out of 19 samples were well bleached. In many well-bleached samples, there wa......We report on OSL dose distributions derived from small-aliquot and single grains of quartz in young fluvial sediments sampled from the Penner River basin, South India. The single-grain dose distributions suggest that 13 out of 19 samples were well bleached. In many well-bleached samples......, there was an underestimation in the single-aliquot dose estimates as compared to those from the single grain-the difference between average dose estimates determined by the two methods ranged from similar to 1% to 31%. Such a dose underestimation was not detectable in poorly bleached samples. Various possible reasons...... perhaps be one of the reasons; this may occur because the stimulation wavelength affects the proportion of the medium and slow components in the initial signal. (c) 2004 Elsevier Ltd. All rights reserved....

  20. High resolution Neutron and Synchrotron Powder Diffraction

    International Nuclear Information System (INIS)

    Hewat, A.W.

    1986-01-01

    The use of high-resolution powder diffraction has grown rapidly in the past years, with the development of Rietveld (1967) methods of data analysis and new high-resolution diffractometers and multidetectors. The number of publications in this area has increased from a handful per year until 1973 to 150 per year in 1984, with a ten-year total of over 1000. These papers cover a wide area of solid state-chemistry, physics and materials science, and have been grouped under 20 subject headings, ranging from catalysts to zeolites, and from battery electrode materials to pre-stressed superconducting wires. In 1985 two new high-resolution diffractometers are being commissioned, one at the SNS laboratory near Oxford, and one at the ILL in Grenoble. In different ways these machines represent perhaps the ultimate that can be achieved with neutrons and will permit refinement of complex structures with about 250 parameters and unit cell volumes of about 2500 Angstrom/sp3/. The new European Synchotron Facility will complement the Grenoble neutron diffractometers, and extend the role of high-resolution powder diffraction to the direct solution of crystal structures, pioneered in Sweden

  1. High resolution (transformers.

    Science.gov (United States)

    Garcia-Souto, Jose A; Lamela-Rivera, Horacio

    2006-10-16

    A novel fiber-optic interferometric sensor is presented for vibrations measurements and analysis. In this approach, it is shown applied to the vibrations of electrical structures within power transformers. A main feature of the sensor is that an unambiguous optical phase measurement is performed using the direct detection of the interferometer output, without external modulation, for a more compact and stable implementation. High resolution of the interferometric measurement is obtained with this technique (transformers are also highlighted.

  2. High-resolution wavefront control of high-power laser systems

    International Nuclear Information System (INIS)

    Brase, J.; Brown, C.; Carrano, C.; Kartz, M.; Olivier, S.; Pennington, D.; Silva, D.

    1999-01-01

    Nearly every new large-scale laser system application at LLNL has requirements for beam control which exceed the current level of available technology. For applications such as inertial confinement fusion, laser isotope separation, laser machining, and laser the ability to transport significant power to a target while maintaining good beam quality is critical. There are many ways that laser wavefront quality can be degraded. Thermal effects due to the interaction of high-power laser or pump light with the internal optical components or with the ambient gas are common causes of wavefront degradation. For many years, adaptive optics based on thing deformable glass mirrors with piezoelectric or electrostrictive actuators have be used to remove the low-order wavefront errors from high-power laser systems. These adaptive optics systems have successfully improved laser beam quality, but have also generally revealed additional high-spatial-frequency errors, both because the low-order errors have been reduced and because deformable mirrors have often introduced some high-spatial-frequency components due to manufacturing errors. Many current and emerging laser applications fall into the high-resolution category where there is an increased need for the correction of high spatial frequency aberrations which requires correctors with thousands of degrees of freedom. The largest Deformable Mirrors currently available have less than one thousand degrees of freedom at a cost of approximately $1M. A deformable mirror capable of meeting these high spatial resolution requirements would be cost prohibitive. Therefore a new approach using a different wavefront control technology is needed. One new wavefront control approach is the use of liquid-crystal (LC) spatial light modulator (SLM) technology for the controlling the phase of linearly polarized light. Current LC SLM technology provides high-spatial-resolution wavefront control, with hundreds of thousands of degrees of freedom, more

  3. Radiocromic film, TLD, OSL and 'Paracas Phantom' by dosimetric intercomparation in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Paucar Jauregui, R.; Condori Marcos, P.; Vidarte Garcia, F.

    2008-01-01

    Full text: In Peru, one deals to patients with arteriovenous malformations or cerebral tumors by means of stereotactic radiosurgery, using fine photon beams of high energy of 6 MeV, generated by a linear accelerator Varian 2100 Clinac CD of the Complejo Hospitalario San Pablo in Lima, Peru. In this work we describes the 'Dosimetric Intercomparation System of the Quality Assurance Program in Stereotactic Radiosurgery of the Complejo Hospitalario San Pablo (DIS)'. The DIS allows to guarantee application of the doses with high accuracy. It shows the good performance of the Local DIS's components: dosimetry of radiocromics films, dosimetry termoluminiscent (TLD), dosimetry of optically stimulated luminescence (OSL) and an anthropomorphic phantom of head constructed locally, denominated 'Paracas Phantom'. Also, in the International DIS practiced with The University of Texas Md Anderson Cancer Center, stands out results within the ranges: a) Dose to the center of the target (RDS/Institution): 0,95-1,05; b) Treated volumen (Measured/Institution): 0,75 - 1,05; c) Ratio of measure treated volume to target volume: 1,00 - 2,00; and d) Minimum dose to target (Minimum dose/Prescription dose): >0,90. It concludes that the DIS is important for the good decision making on the radiological safety of the patients dealt with stereotactic radiosurgery. (author)

  4. OSL properties of three commonly available salt brands in India for its use in accident dosimetry

    Science.gov (United States)

    Singh, A. K.; Menon, S. N.; Kadam, S. Y.; Koul, D. K.; Datta, D.

    2018-03-01

    Thermally stimulated luminescence (TL) and Optically Stimulated Luminescence (OSL) characterization of three commonly available salt brands in India were undertaken for their application in accident dosimetry. The investigations showed that the luminescence properties differed to some extent with that reported in literature. Dosimetric properties of these salt samples showed that these can be useful in accident dosimetry. Based on the sensitization and fading behaviour of the samples a Single Aliquot Regenerative (SAR) protocol has been proposed for dose estimation.

  5. High resolution optical DNA mapping

    Science.gov (United States)

    Baday, Murat

    Many types of diseases including cancer and autism are associated with copy-number variations in the genome. Most of these variations could not be identified with existing sequencing and optical DNA mapping methods. We have developed Multi-color Super-resolution technique, with potential for high throughput and low cost, which can allow us to recognize more of these variations. Our technique has made 10--fold improvement in the resolution of optical DNA mapping. Using a 180 kb BAC clone as a model system, we resolved dense patterns from 108 fluorescent labels of two different colors representing two different sequence-motifs. Overall, a detailed DNA map with 100 bp resolution was achieved, which has the potential to reveal detailed information about genetic variance and to facilitate medical diagnosis of genetic disease.

  6. High-Resolution Electronics: Spontaneous Patterning of High-Resolution Electronics via Parallel Vacuum Ultraviolet (Adv. Mater. 31/2016).

    Science.gov (United States)

    Liu, Xuying; Kanehara, Masayuki; Liu, Chuan; Sakamoto, Kenji; Yasuda, Takeshi; Takeya, Jun; Minari, Takeo

    2016-08-01

    On page 6568, T. Minari and co-workers describe spontaneous patterning based on the parallel vacuum ultraviolet (PVUV) technique, enabling the homogeneous integration of complex, high-resolution electronic circuits, even on large-scale, flexible, transparent substrates. Irradiation of PVUV to the hydrophobic polymer surface precisely renders the selected surface into highly wettable regions with sharply defined boundaries, which spontaneously guides a metal nanoparticle ink into a series of circuit lines and gaps with the widths down to a resolution of 1 μm. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. High resolution UV spectroscopy and laser-focused nanofabrication

    NARCIS (Netherlands)

    Myszkiewicz, G.

    2005-01-01

    This thesis combines two at first glance different techniques: High Resolution Laser Induced Fluorescence Spectroscopy (LIF) of small aromatic molecules and Laser Focusing of atoms for Nanofabrication. The thesis starts with the introduction to the high resolution LIF technique of small aromatic

  8. High-resolution spectrometer at PEP

    International Nuclear Information System (INIS)

    Weiss, J.M.; HRS Collaboration.

    1982-01-01

    A description is presented of the High Resolution Spectrometer experiment (PEP-12) now running at PEP. The advanced capabilities of the detector are demonstrated with first physics results expected in the coming months

  9. High-resolution structure of the native histone octamer

    International Nuclear Information System (INIS)

    Wood, Christopher M.; Nicholson, James M.; Lambert, Stanley J.; Chantalat, Laurent; Reynolds, Colin D.; Baldwin, John P.

    2005-01-01

    The high-resolution (1.90 Å) model of the native histone octamer allows structural comparisons to be made with the nucleosome-core particle, along with an identification of a likely core-histone binding site. Crystals of native histone octamers (H2A–H2B)–(H4–H3)–(H3′–H4′)–(H2B′–H2A′) from chick erythrocytes in 2 M KCl, 1.35 M potassium phosphate pH 6.9 diffract X-rays to 1.90 Å resolution, yielding a structure with an R work value of 18.7% and an R free of 22.2%. The crystal space group is P6 5 , the asymmetric unit of which contains one complete octamer. This high-resolution model of the histone-core octamer allows further insight into intermolecular interactions, including water molecules, that dock the histone dimers to the tetramer in the nucleosome-core particle and have relevance to nucleosome remodelling. The three key areas analysed are the H2A′–H3–H4 molecular cluster (also H2A–H3′–H4′), the H4–H2B′ interaction (also H4′–H2B) and the H2A′–H4 β-sheet interaction (also H2A–H4′). The latter of these three regions is important to nucleosome remodelling by RNA polymerase II, as it is shown to be a likely core-histone binding site, and its disruption creates an instability in the nucleosome-core particle. A majority of the water molecules in the high-resolution octamer have positions that correlate to similar positions in the high-resolution nucleosome-core particle structure, suggesting that the high-resolution octamer model can be used for comparative studies with the high-resolution nucleosome-core particle

  10. Requirements on high resolution detectors

    Energy Technology Data Exchange (ETDEWEB)

    Koch, A. [European Synchrotron Radiation Facility, Grenoble (France)

    1997-02-01

    For a number of microtomography applications X-ray detectors with a spatial resolution of 1 {mu}m are required. This high spatial resolution will influence and degrade other parameters of secondary importance like detective quantum efficiency (DQE), dynamic range, linearity and frame rate. This note summarizes the most important arguments, for and against those detector systems which could be considered. This article discusses the mutual dependencies between the various figures which characterize a detector, and tries to give some ideas on how to proceed in order to improve present technology.

  11. High-resolution clean-sc

    NARCIS (Netherlands)

    Sijtsma, P.; Snellen, M.

    2016-01-01

    In this paper a high-resolution extension of CLEAN-SC is proposed: HR-CLEAN-SC. Where CLEAN-SC uses peak sources in “dirty maps” to define so-called source components, HR-CLEAN-SC takes advantage of the fact that source components can likewise be derived from points at some distance from the peak,

  12. Planning for shallow high resolution seismic surveys

    CSIR Research Space (South Africa)

    Fourie, CJS

    2008-11-01

    Full Text Available of the input wave. This information can be used in conjunction with this spreadsheet to aid the geophysicist in designing shallow high resolution seismic surveys to achieve maximum resolution and penetration. This Excel spreadsheet is available free from...

  13. Thermally assisted OSL application for equivalent dose estimation; comparison of multiple equivalent dose values as well as saturation levels determined by luminescence and ESR techniques for a sedimentary sample collected from a fault gouge

    Energy Technology Data Exchange (ETDEWEB)

    Şahiner, Eren, E-mail: sahiner@ankara.edu.tr; Meriç, Niyazi, E-mail: meric@ankara.edu.tr; Polymeris, George S., E-mail: gspolymeris@ankara.edu.tr

    2017-02-01

    Highlights: • Multiple equivalent dose estimations were carried out. • Additive ESR and regenerative luminescence were applied. • Preliminary SAR results employing TA-OSL signal were discussed. • Saturation levels of ESR and luminescence were investigated. • IRSL{sub 175} and SAR TA-OSL stand as very promising for large doses. - Abstract: Equivalent dose estimation (D{sub e}) constitutes the most important part of either trap-charge dating techniques or dosimetry applications. In the present work, multiple, independent equivalent dose estimation approaches were adopted, using both luminescence and ESR techniques; two different minerals were studied, namely quartz as well as feldspathic polymineral samples. The work is divided into three independent parts, depending on the type of signal employed. Firstly, different D{sub e} estimation approaches were carried out on both polymineral and contaminated quartz, using single aliquot regenerative dose protocols employing conventional OSL and IRSL signals, acquired at different temperatures. Secondly, ESR equivalent dose estimations using the additive dose procedure both at room temperature and at 90 K were discussed. Lastly, for the first time in the literature, a single aliquot regenerative protocol employing a thermally assisted OSL signal originating from Very Deep Traps was applied for natural minerals. Rejection criteria such as recycling and recovery ratios are also presented. The SAR protocol, whenever applied, provided with compatible D{sub e} estimations with great accuracy, independent on either the type of mineral or the stimulation temperature. Low temperature ESR signals resulting from Al and Ti centers indicate very large D{sub e} values due to bleaching in-ability, associated with large uncertainty values. Additionally, dose saturation of different approaches was investigated. For the signal arising from Very Deep Traps in quartz saturation is extended almost by one order of magnitude. It is

  14. Gamma-ray spectrometer system with high efficiency and high resolution

    International Nuclear Information System (INIS)

    Moss, C.E.; Bernard, W.; Dowdy, E.J.; Garcia, C.; Lucas, M.C.; Pratt, J.C.

    1983-01-01

    Our gamma-ray spectrometer system, designed for field use, offers high efficiency and high resolution for safeguards applications. The system consists of three 40% high-purity germanium detectors and a LeCroy 3500 data acquisition system that calculates a composite spectrum for the three detectors. The LeCroy 3500 mainframe can be operated remotely from the detector array with control exercised through modems and the telephone system. System performance with a mixed source of 125 Sb, 154 Eu, and 155 Eu confirms the expected efficiency of 120% with the overall resolution showing little degradation over that of the worst detector

  15. High resolution metric imaging payload

    Science.gov (United States)

    Delclaud, Y.

    2017-11-01

    Alcatel Space Industries has become Europe's leader in the field of high and very high resolution optical payloads, in the frame work of earth observation system able to provide military government with metric images from space. This leadership allowed ALCATEL to propose for the export market, within a French collaboration frame, a complete space based system for metric observation.

  16. High-resolution X-ray diffraction studies of multilayers

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Hornstrup, Allan; Schnopper, H. W.

    1988-01-01

    High-resolution X-ray diffraction studies of the perfection of state-of-the-art multilayers are presented. Data were obtained using a triple-axis perfect-crystal X-ray diffractometer. Measurements reveal large-scale figure errors in the substrate. A high-resolution triple-axis set up is required...

  17. Isotope specific resolution recovery image reconstruction in high resolution PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kotasidis, Fotis A. [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva, Switzerland and Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, M20 3LJ, Manchester (United Kingdom); Angelis, Georgios I. [Faculty of Health Sciences, Brain and Mind Research Institute, University of Sydney, NSW 2006, Sydney (Australia); Anton-Rodriguez, Jose; Matthews, Julian C. [Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, Manchester M20 3LJ (United Kingdom); Reader, Andrew J. [Montreal Neurological Institute, McGill University, Montreal QC H3A 2B4, Canada and Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King' s College London, St. Thomas’ Hospital, London SE1 7EH (United Kingdom); Zaidi, Habib [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva (Switzerland); Geneva Neuroscience Centre, Geneva University, CH-1205 Geneva (Switzerland); Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, PO Box 30 001, Groningen 9700 RB (Netherlands)

    2014-05-15

    Purpose: Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measurements. As such, non-optimal PSF models that do not correspond to those needed for the data to be reconstructed are used within resolution modeling (RM) image reconstruction, usually underestimating the true PSF owing to the difference in positron range. In high resolution brain and preclinical imaging, this effect is of particular importance since the PSFs become more positron range limited and isotope-specific PSFs can help maximize the performance benefit from using resolution recovery image reconstruction algorithms. Methods: In this work, the authors used a printing technique to simultaneously measure multiple point sources on the High Resolution Research Tomograph (HRRT), and the authors demonstrated the feasibility of deriving isotope-dependent system matrices from fluorine-18 and carbon-11 point sources. Furthermore, the authors evaluated the impact of incorporating them within RM image reconstruction, using carbon-11 phantom and clinical datasets on the HRRT. Results: The results obtained using these two isotopes illustrate that even small differences in positron range can result in different PSF maps, leading to further improvements in contrast recovery when used in image reconstruction. The difference is more pronounced in the centre of the field-of-view where the full width at half maximum (FWHM) from the positron range has a larger contribution to the overall FWHM compared to the edge where the parallax error dominates the overall FWHM. Conclusions: Based on the proposed methodology, measured isotope-specific and spatially variant PSFs can be reliably derived and used for improved spatial resolution and variance performance in resolution

  18. Isotope specific resolution recovery image reconstruction in high resolution PET imaging

    International Nuclear Information System (INIS)

    Kotasidis, Fotis A.; Angelis, Georgios I.; Anton-Rodriguez, Jose; Matthews, Julian C.; Reader, Andrew J.; Zaidi, Habib

    2014-01-01

    Purpose: Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measurements. As such, non-optimal PSF models that do not correspond to those needed for the data to be reconstructed are used within resolution modeling (RM) image reconstruction, usually underestimating the true PSF owing to the difference in positron range. In high resolution brain and preclinical imaging, this effect is of particular importance since the PSFs become more positron range limited and isotope-specific PSFs can help maximize the performance benefit from using resolution recovery image reconstruction algorithms. Methods: In this work, the authors used a printing technique to simultaneously measure multiple point sources on the High Resolution Research Tomograph (HRRT), and the authors demonstrated the feasibility of deriving isotope-dependent system matrices from fluorine-18 and carbon-11 point sources. Furthermore, the authors evaluated the impact of incorporating them within RM image reconstruction, using carbon-11 phantom and clinical datasets on the HRRT. Results: The results obtained using these two isotopes illustrate that even small differences in positron range can result in different PSF maps, leading to further improvements in contrast recovery when used in image reconstruction. The difference is more pronounced in the centre of the field-of-view where the full width at half maximum (FWHM) from the positron range has a larger contribution to the overall FWHM compared to the edge where the parallax error dominates the overall FWHM. Conclusions: Based on the proposed methodology, measured isotope-specific and spatially variant PSFs can be reliably derived and used for improved spatial resolution and variance performance in resolution

  19. Isotope specific resolution recovery image reconstruction in high resolution PET imaging.

    Science.gov (United States)

    Kotasidis, Fotis A; Angelis, Georgios I; Anton-Rodriguez, Jose; Matthews, Julian C; Reader, Andrew J; Zaidi, Habib

    2014-05-01

    Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measurements. As such, non-optimal PSF models that do not correspond to those needed for the data to be reconstructed are used within resolution modeling (RM) image reconstruction, usually underestimating the true PSF owing to the difference in positron range. In high resolution brain and preclinical imaging, this effect is of particular importance since the PSFs become more positron range limited and isotope-specific PSFs can help maximize the performance benefit from using resolution recovery image reconstruction algorithms. In this work, the authors used a printing technique to simultaneously measure multiple point sources on the High Resolution Research Tomograph (HRRT), and the authors demonstrated the feasibility of deriving isotope-dependent system matrices from fluorine-18 and carbon-11 point sources. Furthermore, the authors evaluated the impact of incorporating them within RM image reconstruction, using carbon-11 phantom and clinical datasets on the HRRT. The results obtained using these two isotopes illustrate that even small differences in positron range can result in different PSF maps, leading to further improvements in contrast recovery when used in image reconstruction. The difference is more pronounced in the centre of the field-of-view where the full width at half maximum (FWHM) from the positron range has a larger contribution to the overall FWHM compared to the edge where the parallax error dominates the overall FWHM. Based on the proposed methodology, measured isotope-specific and spatially variant PSFs can be reliably derived and used for improved spatial resolution and variance performance in resolution recovery image reconstruction. The

  20. Study of teflon pads as high doses dosemeters

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2013-01-01

    The aim of this work is to study the Teflon, which is used as a binder in the manufacture of dosimetric tablets, for the feasibility of this material as high dose dosemeter. In this paper we used the technique of thermally stimulated luminescence (OSL) to characterize the dosimetric properties of Teflon. Teflon samples were exposed to different doses of radiation, using a source of gamma radiation ( 60 Co). It was obtained dose-response curve between 100 Gy to 50 kGy and reproducibility of OSL response. The preliminary results show that Teflon is a useful material to high dose dosimetry

  1. Scalable Algorithms for Large High-Resolution Terrain Data

    DEFF Research Database (Denmark)

    Mølhave, Thomas; Agarwal, Pankaj K.; Arge, Lars Allan

    2010-01-01

    In this paper we demonstrate that the technology required to perform typical GIS computations on very large high-resolution terrain models has matured enough to be ready for use by practitioners. We also demonstrate the impact that high-resolution data has on common problems. To our knowledge, so...

  2. High resolution NMR imaging using a high field yokeless permanent magnet.

    Science.gov (United States)

    Kose, Katsumi; Haishi, Tomoyuki

    2011-01-01

    We measured the homogeneity and stability of the magnetic field of a high field (about 1.04 tesla) yokeless permanent magnet with 40-mm gap for high resolution nuclear magnetic resonance (NMR) imaging. Homogeneity was evaluated using a 3-dimensional (3D) lattice phantom and 3D spin-echo imaging sequences. In the central sphere (20-mm diameter), peak-to-peak magnetic field inhomogeneity was about 60 ppm, and the root-mean-square was 8 ppm. We measured room temperature, magnet temperature, and NMR frequency of the magnet simultaneously every minute for about 68 hours with and without the thermal insulator of the magnet. A simple mathematical model described the magnet's thermal property. Based on magnet performance, we performed high resolution (up to [20 µm](2)) imaging with internal NMR lock sequences of several biological samples. Our results demonstrated the usefulness of the high field small yokeless permanent magnet for high resolution NMR imaging.

  3. High resolution NMR imaging using a high field yokeless permanent magnet

    International Nuclear Information System (INIS)

    Kose, Katsumi; Haishi, Tomoyuki

    2011-01-01

    We measured the homogeneity and stability of the magnetic field of a high field (about 1.04 tesla) yokeless permanent magnet with 40-mm gap for high resolution nuclear magnetic resonance (NMR) imaging. Homogeneity was evaluated using a 3-dimensional (3D) lattice phantom and 3D spin-echo imaging sequences. In the central sphere (20-mm diameter), peak-to-peak magnetic field inhomogeneity was about 60 ppm, and the root-mean-square was 8 ppm. We measured room temperature, magnet temperature, and NMR frequency of the magnet simultaneously every minute for about 68 hours with and without the thermal insulator of the magnet. A simple mathematical model described the magnet's thermal property. Based on magnet performance, we performed high resolution (up to [20 μm] 2 ) imaging with internal NMR lock sequences of several biological samples. Our results demonstrated the usefulness of the high field small yokeless permanent magnet for high resolution NMR imaging. (author)

  4. Progress in high-resolution x-ray holographic microscopy

    International Nuclear Information System (INIS)

    Jacobsen, C.; Kirz, J.; Howells, M.; McQuaid, K.; Rothman, S.; Feder, R.; Sayre, D.

    1987-07-01

    Among the various types of x-ray microscopes that have been demonstrated, the holographic microscope has had the largest gap between promise and performance. The difficulties of fabricating x-ray optical elements have led some to view holography as the most attractive method for obtaining the ultimate in high resolution x-ray micrographs; however, we know of no investigations prior to 1987 that clearly demonstrated submicron resolution in reconstructed images. Previous efforts suffered from problems such as limited resolution and dynamic range in the recording media, low coherent x-ray flux, and aberrations and diffraction limits in visible light reconstruction. We have addressed the recording limitations through the use of an undulator x-ray source and high-resolution photoresist recording media. For improved results in the readout and reconstruction steps, we have employed metal shadowing and transmission electron microscopy, along with numerical reconstruction techniques. We believe that this approach will allow holography to emerge as a practical method of high-resolution x-ray microscopy. 30 refs., 4 figs

  5. Progress in high-resolution x-ray holographic microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, C.; Kirz, J.; Howells, M.; McQuaid, K.; Rothman, S.; Feder, R.; Sayre, D.

    1987-07-01

    Among the various types of x-ray microscopes that have been demonstrated, the holographic microscope has had the largest gap between promise and performance. The difficulties of fabricating x-ray optical elements have led some to view holography as the most attractive method for obtaining the ultimate in high resolution x-ray micrographs; however, we know of no investigations prior to 1987 that clearly demonstrated submicron resolution in reconstructed images. Previous efforts suffered from problems such as limited resolution and dynamic range in the recording media, low coherent x-ray flux, and aberrations and diffraction limits in visible light reconstruction. We have addressed the recording limitations through the use of an undulator x-ray source and high-resolution photoresist recording media. For improved results in the readout and reconstruction steps, we have employed metal shadowing and transmission electron microscopy, along with numerical reconstruction techniques. We believe that this approach will allow holography to emerge as a practical method of high-resolution x-ray microscopy. 30 refs., 4 figs.

  6. High-resolution spectroscopy of gases for industrial applications

    DEFF Research Database (Denmark)

    Fateev, Alexander; Clausen, Sønnik

    High-resolution spectroscopy of gases is a powerful technique which has various fundamental and practical applications: in situ simultaneous measurements of gas temperature and gas composition, radiative transfer modeling, validation of existing and developing of new databases and etc. Existing...... databases (e.g. HITRAN, HITEMP or CDSD) can normally be used for absorption spectra calculations at limited temperature/pressure ranges. Therefore experimental measurements of absorption/transmission spectra gases (e.g. CO2, H2O or SO2) at high-resolution and elevated temperatures are essential both...... for analysis of complex experimental data and further development of the databases. High-temperature gas cell facilities available at DTU Chemical Engineering are presented and described. The gas cells and high-resolution spectrometers allow us to perform high-quality reference measurements of gases relevant...

  7. Towards high-resolution positron emission tomography for small volumes

    International Nuclear Information System (INIS)

    McKee, B.T.A.

    1982-01-01

    Some arguments are made regarding the medical usefulness of high spatial resolution in positron imaging, even if limited to small imaged volumes. Then the intrinsic limitations to spatial resolution in positron imaging are discussed. The project to build a small-volume, high resolution animal research prototype (SHARP) positron imaging system is described. The components of the system, particularly the detectors, are presented and brief mention is made of data acquisition and image reconstruction methods. Finally, some preliminary imaging results are presented; a pair of isolated point sources and 18 F in the bones of a rabbit. Although the detector system is not fully completed, these first results indicate that the goals of high sensitivity and high resolution (4 mm) have been realized. (Auth.)

  8. High-resolution X-ray crystal structure of bovine H-protein using the high-pressure cryocooling method

    International Nuclear Information System (INIS)

    Higashiura, Akifumi; Ohta, Kazunori; Masaki, Mika; Sato, Masaru; Inaka, Koji; Tanaka, Hiroaki; Nakagawa, Atsushi

    2013-01-01

    Using the high-pressure cryocooling method, the high-resolution X-ray crystal structure of bovine H-protein was determined at 0.86 Å resolution. This is the first ultra-high-resolution structure obtained from a high-pressure cryocooled crystal. Recently, many technical improvements in macromolecular X-ray crystallography have increased the number of structures deposited in the Protein Data Bank and improved the resolution limit of protein structures. Almost all high-resolution structures have been determined using a synchrotron radiation source in conjunction with cryocooling techniques, which are required in order to minimize radiation damage. However, optimization of cryoprotectant conditions is a time-consuming and difficult step. To overcome this problem, the high-pressure cryocooling method was developed (Kim et al., 2005 ▶) and successfully applied to many protein-structure analyses. In this report, using the high-pressure cryocooling method, the X-ray crystal structure of bovine H-protein was determined at 0.86 Å resolution. Structural comparisons between high- and ambient-pressure cryocooled crystals at ultra-high resolution illustrate the versatility of this technique. This is the first ultra-high-resolution X-ray structure obtained using the high-pressure cryocooling method

  9. High resolution drift chambers

    International Nuclear Information System (INIS)

    Va'vra, J.

    1985-07-01

    High precision drift chambers capable of achieving less than or equal to 50 μm resolutions are discussed. In particular, we compare so called cool and hot gases, various charge collection geometries, several timing techniques and we also discuss some systematic problems. We also present what we would consider an ''ultimate'' design of the vertex chamber. 50 refs., 36 figs., 6 tabs

  10. OSL dating of fine-grained quartz from Holocene Yangtze delta sediments

    DEFF Research Database (Denmark)

    Sugisaki, Saiko; Buylaert, Jan-Pieter; Murray, Andrew

    2015-01-01

    Holocene flood events in the Yangtze River are associated with variations in East Asian Summer Monsoon (EASM) precipitation, and so Yangtze delta sediments may preserve information about the frequency and magnitude of EASM precipitation. These flood/drought cycles of the EASM directly affect...... the living standards of East Asian population. However, despite its importance, little chronological control is available for the Yangtze Delta sediments; because biogenic carbonate only occurs sporadically, it has proved the difficulty to discuss sedimentation mechanisms and rates in any detail. In 2013 two...... sediment cores (YD13-G3 and H1) were taken from the Yangtze subaqueous delta to investigate precipitation history. In this study, we investigate the potential of quartz OSL dating of the fine silt fraction (fine-grained quartz; 4-11 μm) from these cores to estimate the depositional age of the sediments. We...

  11. High resolution neutron spectroscopy for helium isotopes

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; Klages, H.O.; Schmalz, G.; Haesner, B.H.; Kecskemeti, J.; Schwarz, P.; Wilczynski, J.

    1992-01-01

    A high resolution fast neutron time-of-flight spectrometer is described, neutron time-of-flight spectra are taken using a specially designed TDC in connection to an on-line computer. The high time-of-flight resolution of 5 ps/m enabled the study of the total cross section of 4 He for neutrons near the 3/2 + resonance in the 5 He nucleus. The resonance parameters were determined by a single level Breit-Winger fit to the data. (orig.)

  12. A high-resolution regional reanalysis for Europe

    Science.gov (United States)

    Ohlwein, C.

    2015-12-01

    Reanalyses gain more and more importance as a source of meteorological information for many purposes and applications. Several global reanalyses projects (e.g., ERA, MERRA, CSFR, JMA9) produce and verify these data sets to provide time series as long as possible combined with a high data quality. Due to a spatial resolution down to 50-70km and 3-hourly temporal output, they are not suitable for small scale problems (e.g., regional climate assessment, meso-scale NWP verification, input for subsequent models such as river runoff simulations). The implementation of regional reanalyses based on a limited area model along with a data assimilation scheme is able to generate reanalysis data sets with high spatio-temporal resolution. Within the Hans-Ertel-Centre for Weather Research (HErZ), the climate monitoring branch concentrates efforts on the assessment and analysis of regional climate in Germany and Europe. In joint cooperation with DWD (German Meteorological Service), a high-resolution reanalysis system based on the COSMO model has been developed. The regional reanalysis for Europe matches the domain of the CORDEX EURO-11 specifications, albeit at a higher spatial resolution, i.e., 0.055° (6km) instead of 0.11° (12km) and comprises the assimilation of observational data using the existing nudging scheme of COSMO complemented by a special soil moisture analysis with boundary conditions provided by ERA-Interim data. The reanalysis data set covers the past 20 years. Extensive evaluation of the reanalysis is performed using independent observations with special emphasis on precipitation and high-impact weather situations indicating a better representation of small scale variability. Further, the evaluation shows an added value of the regional reanalysis with respect to the forcing ERA Interim reanalysis and compared to a pure high-resolution dynamical downscaling approach without data assimilation.

  13. Energy dependence measurement of small-type optically stimulated luminescence (OSL) dosimeter by means of characteristic X-rays induced with general diagnostic X-ray equipment.

    Science.gov (United States)

    Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2016-01-01

    For X-ray inspections by way of general X-ray equipment, it is important to measure an entrance-skin dose. Recently, a small optically stimulated luminescence (OSL) dosimeter was made commercially available by Landauer, Inc. The dosimeter does not interfere with the medical images; therefore, it is expected to be a convenient detector for measuring personal exposure doses. In an actual clinical situation, it is assumed that X-rays of different energies will be detected by a dosimeter. For evaluation of the exposure dose measured by a dosimeter, it is necessary to know the energy dependence of the dosimeter. Our aim in this study was to measure the energy dependence of the OSL dosimeter experimentally in the diagnostic X-ray region. Metal samples weighing several grams were irradiated and, in this way, characteristic X-rays having energies ranging from 8 to 85 keV were generated. Using these mono-energetic X-rays, the dosimeter was irradiated. Simultaneously, the fluence of the X-rays was determined with a CdTe detector. The energy-dependent efficiency of the dosimeter was derived from the measured value of the dosimeter and the fluence. Moreover, the energy-dependent efficiency was calculated by Monte-Carlo simulation. The efficiency obtained in the experiment was in good agreement with that of the simulation. In conclusion, our proposed method, in which characteristic X-rays are used, is valuable for measurement of the energy dependence of a small OSL dosimeter in the diagnostic X-ray region.

  14. Automated data processing of high-resolution mass spectra

    DEFF Research Database (Denmark)

    Hansen, Michael Adsetts Edberg; Smedsgaard, Jørn

    of the massive amounts of data. We present an automated data processing method to quantitatively compare large numbers of spectra from the analysis of complex mixtures, exploiting the full quality of high-resolution mass spectra. By projecting all detected ions - within defined intervals on both the time...... infusion of crude extracts into the source taking advantage of the high sensitivity, high mass resolution and accuracy and the limited fragmentation. Unfortunately, there has not been a comparable development in the data processing techniques to fully exploit gain in high resolution and accuracy...... infusion analyses of crude extract to find the relationship between species from several species terverticillate Penicillium, and also that the ions responsible for the segregation can be identified. Furthermore the process can automate the process of detecting unique species and unique metabolites....

  15. Achieving sensitive, high-resolution laser spectroscopy at CRIS

    Energy Technology Data Exchange (ETDEWEB)

    Groote, R. P. de [Instituut voor Kern- en Stralingsfysica, KU Leuven (Belgium); Lynch, K. M., E-mail: kara.marie.lynch@cern.ch [EP Department, CERN, ISOLDE (Switzerland); Wilkins, S. G. [The University of Manchester, School of Physics and Astronomy (United Kingdom); Collaboration: the CRIS collaboration

    2017-11-15

    The Collinear Resonance Ionization Spectroscopy (CRIS) experiment, located at the ISOLDE facility, has recently performed high-resolution laser spectroscopy, with linewidths down to 20 MHz. In this article, we present the modifications to the beam line and the newly-installed laser systems that have made sensitive, high-resolution measurements possible. Highlights of recent experimental campaigns are presented.

  16. An atlas of high-resolution IRAS maps on nearby galaxies

    Science.gov (United States)

    Rice, Walter

    1993-01-01

    An atlas of far-infrared IRAS maps with near 1 arcmin angular resolution of 30 optically large galaxies is presented. The high-resolution IRAS maps were produced with the Maximum Correlation Method (MCM) image construction and enhancement technique developed at IPAC. The MCM technique, which recovers the spatial information contained in the overlapping detector data samples of the IRAS all-sky survey scans, is outlined and tests to verify the structural reliability and photometric integrity of the high-resolution maps are presented. The infrared structure revealed in individual galaxies is discussed. The atlas complements the IRAS Nearby Galaxy High-Resolution Image Atlas, the high-resolution galaxy images encoded in FITS format, which is provided to the astronomical community as an IPAC product.

  17. Exploring procedures for the rapid assessment of optically stimulated luminescence range-finder ages

    International Nuclear Information System (INIS)

    Roberts, Helen M.; Durcan, Julie A.; Duller, Geoff A.T.

    2009-01-01

    Optically stimulated luminescence (OSL) dating of sediments is a lengthy, labour-intensive, and time-consuming procedure. However, in some situations a rough approximation of the OSL age is all that is necessary e.g. for a pilot field campaign, to plan a sampling strategy, or to determine the resolution required for a dating campaign. Thus, it would be useful to establish an approximate OSL age without the lengthy and involved processes normally used. This paper explores how the standard procedures involved in OSL age determinations can be simplified to yield range-finder ages. Three areas are examined, namely, laboratory preparation, D e estimation, and dose-rate determination. The consequences of circumventing some of the preparation and measurement steps of conventional OSL dating are examined for a variety of sediments, by comparing the OSL range-finder ages to those obtained using full quartz OSL preparation and measurement procedures.

  18. Development of high speed integrated circuit for very high resolution timing measurements

    International Nuclear Information System (INIS)

    Mester, Christian

    2009-10-01

    A multi-channel high-precision low-power time-to-digital converter application specific integrated circuit for high energy physics applications has been designed and implemented in a 130 nm CMOS process. To reach a target resolution of 24.4 ps, a novel delay element has been conceived. This nominal resolution has been experimentally verified with a prototype, with a minimum resolution of 19 ps. To further improve the resolution, a new interpolation scheme has been described. The ASIC has been designed to use a reference clock with the LHC bunch crossing frequency of 40 MHz and generate all required timing signals internally, to ease to use within the framework of an LHC upgrade. Special care has been taken to minimise the power consumption. (orig.)

  19. Development of high speed integrated circuit for very high resolution timing measurements

    Energy Technology Data Exchange (ETDEWEB)

    Mester, Christian

    2009-10-15

    A multi-channel high-precision low-power time-to-digital converter application specific integrated circuit for high energy physics applications has been designed and implemented in a 130 nm CMOS process. To reach a target resolution of 24.4 ps, a novel delay element has been conceived. This nominal resolution has been experimentally verified with a prototype, with a minimum resolution of 19 ps. To further improve the resolution, a new interpolation scheme has been described. The ASIC has been designed to use a reference clock with the LHC bunch crossing frequency of 40 MHz and generate all required timing signals internally, to ease to use within the framework of an LHC upgrade. Special care has been taken to minimise the power consumption. (orig.)

  20. High-resolution MRI in detecting subareolar breast abscess.

    Science.gov (United States)

    Fu, Peifen; Kurihara, Yasuyuki; Kanemaki, Yoshihide; Okamoto, Kyoko; Nakajima, Yasuo; Fukuda, Mamoru; Maeda, Ichiro

    2007-06-01

    Because subareolar breast abscess has a high recurrence rate, a more effective imaging technique is needed to comprehensively visualize the lesions and guide surgery. We performed a high-resolution MRI technique using a microscopy coil to reveal the characteristics and extent of subareolar breast abscess. High-resolution MRI has potential diagnostic value in subareolar breast abscess. This technique can be used to guide surgery with the aim of reducing the recurrence rate.

  1. Recent applications of gas chromatography with high-resolution mass spectrometry.

    Science.gov (United States)

    Špánik, Ivan; Machyňáková, Andrea

    2018-01-01

    Gas chromatography coupled to high-resolution mass spectrometry is a powerful analytical method that combines excellent separation power of gas chromatography with improved identification based on an accurate mass measurement. These features designate gas chromatography with high-resolution mass spectrometry as the first choice for identification and structure elucidation of unknown volatile and semi-volatile organic compounds. Gas chromatography with high-resolution mass spectrometry quantitative analyses was previously focused on the determination of dioxins and related compounds using magnetic sector type analyzers, a standing requirement of many international standards. The introduction of a quadrupole high-resolution time-of-flight mass analyzer broadened interest in this method and novel applications were developed, especially for multi-target screening purposes. This review is focused on the development and the most interesting applications of gas chromatography coupled to high-resolution mass spectrometry towards analysis of environmental matrices, biological fluids, and food safety since 2010. The main attention is paid to various approaches and applications of gas chromatography coupled to high-resolution mass spectrometry for non-target screening to identify contaminants and to characterize the chemical composition of environmental, food, and biological samples. The most interesting quantitative applications, where a significant contribution of gas chromatography with high-resolution mass spectrometry over the currently used methods is expected, will be discussed as well. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Multi-resolution voxel phantom modeling: a high-resolution eye model for computational dosimetry.

    Science.gov (United States)

    Caracappa, Peter F; Rhodes, Ashley; Fiedler, Derek

    2014-09-21

    Voxel models of the human body are commonly used for simulating radiation dose with a Monte Carlo radiation transport code. Due to memory limitations, the voxel resolution of these computational phantoms is typically too large to accurately represent the dimensions of small features such as the eye. Recently reduced recommended dose limits to the lens of the eye, which is a radiosensitive tissue with a significant concern for cataract formation, has lent increased importance to understanding the dose to this tissue. A high-resolution eye model is constructed using physiological data for the dimensions of radiosensitive tissues, and combined with an existing set of whole-body models to form a multi-resolution voxel phantom, which is used with the MCNPX code to calculate radiation dose from various exposure types. This phantom provides an accurate representation of the radiation transport through the structures of the eye. Two alternate methods of including a high-resolution eye model within an existing whole-body model are developed. The accuracy and performance of each method is compared against existing computational phantoms.

  3. High-resolution intravital microscopy.

    Directory of Open Access Journals (Sweden)

    Volker Andresen

    Full Text Available Cellular communication constitutes a fundamental mechanism of life, for instance by permitting transfer of information through synapses in the nervous system and by leading to activation of cells during the course of immune responses. Monitoring cell-cell interactions within living adult organisms is crucial in order to draw conclusions on their behavior with respect to the fate of cells, tissues and organs. Until now, there is no technology available that enables dynamic imaging deep within the tissue of living adult organisms at sub-cellular resolution, i.e. detection at the level of few protein molecules. Here we present a novel approach called multi-beam striped-illumination which applies for the first time the principle and advantages of structured-illumination, spatial modulation of the excitation pattern, to laser-scanning-microscopy. We use this approach in two-photon-microscopy--the most adequate optical deep-tissue imaging-technique. As compared to standard two-photon-microscopy, it achieves significant contrast enhancement and up to 3-fold improved axial resolution (optical sectioning while photobleaching, photodamage and acquisition speed are similar. Its imaging depth is comparable to multifocal two-photon-microscopy and only slightly less than in standard single-beam two-photon-microscopy. Precisely, our studies within mouse lymph nodes demonstrated 216% improved axial and 23% improved lateral resolutions at a depth of 80 µm below the surface. Thus, we are for the first time able to visualize the dynamic interactions between B cells and immune complex deposits on follicular dendritic cells within germinal centers (GCs of live mice. These interactions play a decisive role in the process of clonal selection, leading to affinity maturation of the humoral immune response. This novel high-resolution intravital microscopy method has a huge potential for numerous applications in neurosciences, immunology, cancer research and

  4. High-Resolution Intravital Microscopy

    Science.gov (United States)

    Andresen, Volker; Pollok, Karolin; Rinnenthal, Jan-Leo; Oehme, Laura; Günther, Robert; Spiecker, Heinrich; Radbruch, Helena; Gerhard, Jenny; Sporbert, Anje; Cseresnyes, Zoltan; Hauser, Anja E.; Niesner, Raluca

    2012-01-01

    Cellular communication constitutes a fundamental mechanism of life, for instance by permitting transfer of information through synapses in the nervous system and by leading to activation of cells during the course of immune responses. Monitoring cell-cell interactions within living adult organisms is crucial in order to draw conclusions on their behavior with respect to the fate of cells, tissues and organs. Until now, there is no technology available that enables dynamic imaging deep within the tissue of living adult organisms at sub-cellular resolution, i.e. detection at the level of few protein molecules. Here we present a novel approach called multi-beam striped-illumination which applies for the first time the principle and advantages of structured-illumination, spatial modulation of the excitation pattern, to laser-scanning-microscopy. We use this approach in two-photon-microscopy - the most adequate optical deep-tissue imaging-technique. As compared to standard two-photon-microscopy, it achieves significant contrast enhancement and up to 3-fold improved axial resolution (optical sectioning) while photobleaching, photodamage and acquisition speed are similar. Its imaging depth is comparable to multifocal two-photon-microscopy and only slightly less than in standard single-beam two-photon-microscopy. Precisely, our studies within mouse lymph nodes demonstrated 216% improved axial and 23% improved lateral resolutions at a depth of 80 µm below the surface. Thus, we are for the first time able to visualize the dynamic interactions between B cells and immune complex deposits on follicular dendritic cells within germinal centers (GCs) of live mice. These interactions play a decisive role in the process of clonal selection, leading to affinity maturation of the humoral immune response. This novel high-resolution intravital microscopy method has a huge potential for numerous applications in neurosciences, immunology, cancer research and developmental biology

  5. Hyper-resolution urban flood modeling using high-resolution radar precipitation and LiDAR data

    Science.gov (United States)

    Noh, S. J.; Lee, S.; Lee, J.; Seo, D. J.

    2016-12-01

    Floods occur most frequently among all natural hazards, often causing widespread economic damage and loss of human lives. In particular, urban flooding is becoming increasingly costly and difficult to manage with a greater concentration of population and assets in urban centers. Despite of known benefits for accurate representation of small scale features and flow interaction among different flow domains, which have significant impact on flood propagation, high-resolution modeling has not been fully utilized due to expensive computation and various uncertainties from model structure, input and parameters. In this study, we assess the potential of hyper-resolution hydrologic-hydraulic modeling using high-resolution radar precipitation and LiDAR data for improved urban flood prediction and hazard mapping. We describe a hyper-resolution 1D-2D coupled urban flood model for pipe and surface flows and evaluate the accuracy of the street-level inundation information produced. For detailed geometric representation of urban areas and for computational efficiency, we use 1 m-resolution topographical data, processed from LiDAR measurements, in conjunction with adaptive mesh refinement. For street-level simulation in large urban areas at grid sizes of 1 to 10 m, a hybrid parallel computing scheme using MPI and openMP is also implemented in a high-performance computing system. The modeling approach developed is applied for the Johnson Creek Catchment ( 40 km2), which makes up the Arlington Urban Hydroinformatics Testbed. In addition, discussion will be given on availability of hyper-resolution simulation archive for improved real-time flood mapping.

  6. Testing the accuracy of a Bayesian central-dose model for single-grain OSL, using known-age samples

    DEFF Research Database (Denmark)

    Guerin, Guillaume; Combès, Benoit; Lahaye, Christelle

    2015-01-01

    on multi-grain OSL age estimates, these samples are presumed to have been both well-bleached at burial, and unaffected by mixing after deposition. Two ways of estimating single-grain ages are then compared: the standard approach on the one hand, consisting of applying the Central Age Model to De values...... for well-bleached samples; (ii) dose recovery experiments do not seem to be a very reliable tool to estimate the accuracy of a SAR measurement protocol for age determination....

  7. Analysis of the impact of spatial resolution on land/water classifications using high-resolution aerial imagery

    Science.gov (United States)

    Enwright, Nicholas M.; Jones, William R.; Garber, Adrienne L.; Keller, Matthew J.

    2014-01-01

    Long-term monitoring efforts often use remote sensing to track trends in habitat or landscape conditions over time. To most appropriately compare observations over time, long-term monitoring efforts strive for consistency in methods. Thus, advances and changes in technology over time can present a challenge. For instance, modern camera technology has led to an increasing availability of very high-resolution imagery (i.e. submetre and metre) and a shift from analogue to digital photography. While numerous studies have shown that image resolution can impact the accuracy of classifications, most of these studies have focused on the impacts of comparing spatial resolution changes greater than 2 m. Thus, a knowledge gap exists on the impacts of minor changes in spatial resolution (i.e. submetre to about 1.5 m) in very high-resolution aerial imagery (i.e. 2 m resolution or less). This study compared the impact of spatial resolution on land/water classifications of an area dominated by coastal marsh vegetation in Louisiana, USA, using 1:12,000 scale colour-infrared analogue aerial photography (AAP) scanned at four different dot-per-inch resolutions simulating ground sample distances (GSDs) of 0.33, 0.54, 1, and 2 m. Analysis of the impact of spatial resolution on land/water classifications was conducted by exploring various spatial aspects of the classifications including density of waterbodies and frequency distributions in waterbody sizes. This study found that a small-magnitude change (1–1.5 m) in spatial resolution had little to no impact on the amount of water classified (i.e. percentage mapped was less than 1.5%), but had a significant impact on the mapping of very small waterbodies (i.e. waterbodies ≤ 250 m2). These findings should interest those using temporal image classifications derived from very high-resolution aerial photography as a component of long-term monitoring programs.

  8. Image Quality in High-resolution and High-cadence Solar Imaging

    Science.gov (United States)

    Denker, C.; Dineva, E.; Balthasar, H.; Verma, M.; Kuckein, C.; Diercke, A.; González Manrique, S. J.

    2018-03-01

    Broad-band imaging and even imaging with a moderate bandpass (about 1 nm) provides a photon-rich environment, where frame selection (lucky imaging) becomes a helpful tool in image restoration, allowing us to perform a cost-benefit analysis on how to design observing sequences for imaging with high spatial resolution in combination with real-time correction provided by an adaptive optics (AO) system. This study presents high-cadence (160 Hz) G-band and blue continuum image sequences obtained with the High-resolution Fast Imager (HiFI) at the 1.5-meter GREGOR solar telescope, where the speckle-masking technique is used to restore images with nearly diffraction-limited resolution. The HiFI employs two synchronized large-format and high-cadence sCMOS detectors. The median filter gradient similarity (MFGS) image-quality metric is applied, among others, to AO-corrected image sequences of a pore and a small sunspot observed on 2017 June 4 and 5. A small region of interest, which was selected for fast-imaging performance, covered these contrast-rich features and their neighborhood, which were part of Active Region NOAA 12661. Modifications of the MFGS algorithm uncover the field- and structure-dependency of this image-quality metric. However, MFGS still remains a good choice for determining image quality without a priori knowledge, which is an important characteristic when classifying the huge number of high-resolution images contained in data archives. In addition, this investigation demonstrates that a fast cadence and millisecond exposure times are still insufficient to reach the coherence time of daytime seeing. Nonetheless, the analysis shows that data acquisition rates exceeding 50 Hz are required to capture a substantial fraction of the best seeing moments, significantly boosting the performance of post-facto image restoration.

  9. Smartphone microendoscopy for high resolution fluorescence imaging

    Directory of Open Access Journals (Sweden)

    Xiangqian Hong

    2016-09-01

    Full Text Available High resolution optical endoscopes are increasingly used in diagnosis of various medical conditions of internal organs, such as the cervix and gastrointestinal (GI tracts, but they are too expensive for use in resource-poor settings. On the other hand, smartphones with high resolution cameras and Internet access have become more affordable, enabling them to diffuse into most rural areas and developing countries in the past decade. In this paper, we describe a smartphone microendoscope that can take fluorescence images with a spatial resolution of 3.1 μm. Images collected from ex vivo, in vitro and in vivo samples using the device are also presented. The compact and cost-effective smartphone microendoscope may be envisaged as a powerful tool for detecting pre-cancerous lesions of internal organs in low and middle-income countries (LMICs.

  10. High resolution mid-infrared spectroscopy based on frequency upconversion

    DEFF Research Database (Denmark)

    Dam, Jeppe Seidelin; Hu, Qi; Tidemand-Lichtenberg, Peter

    2013-01-01

    signals can be analyzed. The obtainable frequency resolution is usually in the nm range where sub nm resolution is preferred in many applications, like gas spectroscopy. In this work we demonstrate how to obtain sub nm resolution when using upconversion. In the presented realization one object point...... high resolution spectral performance by observing emission from hot water vapor in a butane gas burner....

  11. Climate change and high-resolution whole-building numerical modelling

    NARCIS (Netherlands)

    Blocken, B.J.E.; Briggen, P.M.; Schellen, H.L.; Hensen, J.L.M.

    2010-01-01

    This paper briefly discusses the need of high-resolution whole-building numerical modelling in the context of climate change. High-resolution whole-building numerical modelling can be used for detailed analysis of the potential consequences of climate change on buildings and to evaluate remedial

  12. New approach to 3-D, high sensitivity, high mass resolution space plasma composition measurements

    International Nuclear Information System (INIS)

    McComas, D.J.; Nordholt, J.E.

    1990-01-01

    This paper describes a new type of 3-D space plasma composition analyzer. The design combines high sensitivity, high mass resolution measurements with somewhat lower mass resolution but even higher sensitivity measurements in a single compact and robust design. While the lower resolution plasma measurements are achieved using conventional straight-through time-of-flight mass spectrometry, the high mass resolution measurements are made by timing ions reflected in a linear electric field (LEF), where the restoring force that an ion experiences is proportional to the depth it travels into the LEF region. Consequently, the ion's equation of motion in that dimension is that of a simple harmonic oscillator and its travel time is simply proportional to the square root of the ion's mass/charge (m/q). While in an ideal LEF, the m/q resolution can be arbitrarily high, in a real device the resolution is limited by the field linearity which can be achieved. In this paper we describe how a nearly linear field can be produced and discuss how the design can be optimized for various different plasma regimes and spacecraft configurations

  13. High resolution CT of the chest

    Energy Technology Data Exchange (ETDEWEB)

    Barneveld Binkhuysen, F H [Eemland Hospital (Netherlands), Dept. of Radiology

    1996-12-31

    Compared to conventional CT high resolution CT (HRCT) shows several extra anatomical structures which might effect both diagnosis and therapy. The extra anatomical structures were discussed briefly in this article. (18 refs.).

  14. Methodology of high-resolution photography for mural condition database

    Science.gov (United States)

    Higuchi, R.; Suzuki, T.; Shibata, M.; Taniguchi, Y.

    2015-08-01

    Digital documentation is one of the most useful techniques to record the condition of cultural heritage. Recently, high-resolution images become increasingly useful because it is possible to show general views of mural paintings and also detailed mural conditions in a single image. As mural paintings are damaged by environmental stresses, it is necessary to record the details of painting condition on high-resolution base maps. Unfortunately, the cost of high-resolution photography and the difficulty of operating its instruments and software have commonly been an impediment for researchers and conservators. However, the recent development of graphic software makes its operation simpler and less expensive. In this paper, we suggest a new approach to make digital heritage inventories without special instruments, based on our recent our research project in Üzümlü church in Cappadocia, Turkey. This method enables us to achieve a high-resolution image database with low costs, short time, and limited human resources.

  15. High-Resolution MRI in Rectal Cancer

    International Nuclear Information System (INIS)

    Dieguez, Adriana

    2010-01-01

    High-resolution MRI is the best method of assessing the relation of the rectal tumor with the potential circumferential resection margin (CRM). Therefore it is currently considered the method of choice for local staging of rectal cancer. The primary surgery of rectal cancer is total mesorectal excision (TME), which plane of dissection is formed by the mesorectal fascia surrounding mesorectal fat and rectum. This fascia will determine the circumferential margin of resection. At the same time, high resolution MRI allows adequate pre-operative identification of important prognostic risk factors, improving the selection and indication of therapy for each patient. This information includes, besides the circumferential margin of resection, tumor and lymph node staging, extramural vascular invasion and the description of lower rectal tumors. All these should be described in detail in the report, being part of the discussion in the multidisciplinary team, the place where the decisions involving the patient with rectal cancer will take place. The aim of this study is to provide the information necessary to understand the use of high resolution MRI in the identification of prognostic risk factors in rectal cancer. The technical requirements and standardized report for this study will be describe, as well as the anatomical landmarks of importance for the total mesorectal excision (TME), as we have said is the surgery of choice for rectal cancer. (authors) [es

  16. De determination for young samples using the standardised OSL response of coarse-grain quartz

    International Nuclear Information System (INIS)

    Burbidge, C.I.; Duller, G.A.T.; Roberts, H.M.

    2006-01-01

    It has recently been shown that it is possible to construct standardised curves of the sensitivity corrected growth in optically stimulated luminescence (OSL) with exposure to ionising radiation, and that they may be used in the dating of quartz and polymineral samples. Standardised growth curves are particularly advantageous where measurement time is limited, as once they have been defined, only the natural signal and the response to a subsequent test dose are required in order to determine the equivalent dose of a sub-sample. The present study is concerned with the application of the standardised growth curve approach to OSL dating of Holocene age samples. Systematic changes in the shape of the standardised growth curve of coarse-grain quartz are identified as the size of the test dose is varied, because of non-proportionality between the test dose and the luminescence test response. The effect is characterised by fitting the change in gradient of the standardised growth curve as test dose is varied. An equation is defined to describe standardised growth as a function of regenerative dose and test dose. Regenerative dose responses of other samples in this study are treated as unknowns and recovered through different growth curves to compare precision and accuracy of various methods of D e determination. The standardised growth curve is found to yield similar precision to conventional fits of single aliquot regenerative data, but slightly poorer accuracy. The standardised growth curve approach was refined by incorporating the measurement of one regenerative response for each aliquot as well as its natural signal. Measurements of this additional data point for aliquots of 22 samples were used to adjust the standardised growth equation, improving its accuracy. The incorporation of this additional data point also indicated a systematic uncertainty of 2.4% in the estimates of D e

  17. High-resolution coherent three-dimensional spectroscopy of Br2.

    Science.gov (United States)

    Chen, Peter C; Wells, Thresa A; Strangfeld, Benjamin R

    2013-07-25

    In the past, high-resolution spectroscopy has been limited to small, simple molecules that yield relatively uncongested spectra. Larger and more complex molecules have a higher density of peaks and are susceptible to complications (e.g., effects from conical intersections) that can obscure the patterns needed to resolve and assign peaks. Recently, high-resolution coherent two-dimensional (2D) spectroscopy has been used to resolve and sort peaks into easily identifiable patterns for molecules where pattern-recognition has been difficult. For very highly congested spectra, however, the ability to resolve peaks using coherent 2D spectroscopy is limited by the bandwidth of instrumentation. In this article, we introduce and investigate high-resolution coherent three-dimensional spectroscopy (HRC3D) as a method for dealing with heavily congested systems. The resulting patterns are unlike those in high-resolution coherent 2D spectra. Analysis of HRC3D spectra could provide a means for exploring the spectroscopy of large and complex molecules that have previously been considered too difficult to study.

  18. High resolution gamma-ray spectroscopy at high count rates with a prototype High Purity Germanium detector

    Science.gov (United States)

    Cooper, R. J.; Amman, M.; Vetter, K.

    2018-04-01

    High-resolution gamma-ray spectrometers are required for applications in nuclear safeguards, emergency response, and fundamental nuclear physics. To overcome one of the shortcomings of conventional High Purity Germanium (HPGe) detectors, we have developed a prototype device capable of achieving high event throughput and high energy resolution at very high count rates. This device, the design of which we have previously reported on, features a planar HPGe crystal with a reduced-capacitance strip electrode geometry. This design is intended to provide good energy resolution at the short shaping or digital filter times that are required for high rate operation and which are enabled by the fast charge collection afforded by the planar geometry crystal. In this work, we report on the initial performance of the system at count rates up to and including two million counts per second.

  19. Detectors for high resolution dynamic pet

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.; Huesman, R.H.

    1983-05-01

    This report reviews the motivation for high spatial resolution in dynamic positron emission tomography of the head and the technical problems in realizing this objective. We present recent progress in using small silicon photodiodes to measure the energy deposited by 511 keV photons in small BGO crystals with an energy resolution of 9.4% full-width at half-maximum. In conjunction with a suitable phototube coupled to a group of crystals, the photodiode signal to noise ratio is sufficient for the identification of individual crystals both for conventional and time-of-flight positron tomography

  20. Effective noise-suppressed and artifact-reduced reconstruction of SPECT data using a preconditioned alternating projection algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Li, Si; Xu, Yuesheng, E-mail: yxu06@syr.edu [Guangdong Provincial Key Laboratory of Computational Science, School of Mathematics and Computational Sciences, Sun Yat-sen University, Guangzhou 510275 (China); Zhang, Jiahan; Lipson, Edward [Department of Physics, Syracuse University, Syracuse, New York 13244 (United States); Krol, Andrzej; Feiglin, David [Department of Radiology, SUNY Upstate Medical University, Syracuse, New York 13210 (United States); Schmidtlein, C. Ross [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York 10065 (United States); Vogelsang, Levon [Carestream Health, Rochester, New York 14608 (United States); Shen, Lixin [Guangdong Provincial Key Laboratory of Computational Science, School of Mathematics and Computational Sciences, Sun Yat-sen University, Guangzhou 510275, China and Department of Mathematics, Syracuse University, Syracuse, New York 13244 (United States)

    2015-08-15

    Purpose: The authors have recently developed a preconditioned alternating projection algorithm (PAPA) with total variation (TV) regularizer for solving the penalized-likelihood optimization model for single-photon emission computed tomography (SPECT) reconstruction. This algorithm belongs to a novel class of fixed-point proximity methods. The goal of this work is to investigate how PAPA performs while dealing with realistic noisy SPECT data, to compare its performance with more conventional methods, and to address issues with TV artifacts by proposing a novel form of the algorithm invoking high-order TV regularization, denoted as HOTV-PAPA, which has been explored and studied extensively in the present work. Methods: Using Monte Carlo methods, the authors simulate noisy SPECT data from two water cylinders; one contains lumpy “warm” background and “hot” lesions of various sizes with Gaussian activity distribution, and the other is a reference cylinder without hot lesions. The authors study the performance of HOTV-PAPA and compare it with PAPA using first-order TV regularization (TV-PAPA), the Panin–Zeng–Gullberg one-step-late method with TV regularization (TV-OSL), and an expectation–maximization algorithm with Gaussian postfilter (GPF-EM). The authors select penalty-weights (hyperparameters) by qualitatively balancing the trade-off between resolution and image noise separately for TV-PAPA and TV-OSL. However, the authors arrived at the same penalty-weight value for both of them. The authors set the first penalty-weight in HOTV-PAPA equal to the optimal penalty-weight found for TV-PAPA. The second penalty-weight needed for HOTV-PAPA is tuned by balancing resolution and the severity of staircase artifacts. The authors adjust the Gaussian postfilter to approximately match the local point spread function of GPF-EM and HOTV-PAPA. The authors examine hot lesion detectability, study local spatial resolution, analyze background noise properties, estimate mean

  1. Effective noise-suppressed and artifact-reduced reconstruction of SPECT data using a preconditioned alternating projection algorithm

    International Nuclear Information System (INIS)

    Li, Si; Xu, Yuesheng; Zhang, Jiahan; Lipson, Edward; Krol, Andrzej; Feiglin, David; Schmidtlein, C. Ross; Vogelsang, Levon; Shen, Lixin

    2015-01-01

    Purpose: The authors have recently developed a preconditioned alternating projection algorithm (PAPA) with total variation (TV) regularizer for solving the penalized-likelihood optimization model for single-photon emission computed tomography (SPECT) reconstruction. This algorithm belongs to a novel class of fixed-point proximity methods. The goal of this work is to investigate how PAPA performs while dealing with realistic noisy SPECT data, to compare its performance with more conventional methods, and to address issues with TV artifacts by proposing a novel form of the algorithm invoking high-order TV regularization, denoted as HOTV-PAPA, which has been explored and studied extensively in the present work. Methods: Using Monte Carlo methods, the authors simulate noisy SPECT data from two water cylinders; one contains lumpy “warm” background and “hot” lesions of various sizes with Gaussian activity distribution, and the other is a reference cylinder without hot lesions. The authors study the performance of HOTV-PAPA and compare it with PAPA using first-order TV regularization (TV-PAPA), the Panin–Zeng–Gullberg one-step-late method with TV regularization (TV-OSL), and an expectation–maximization algorithm with Gaussian postfilter (GPF-EM). The authors select penalty-weights (hyperparameters) by qualitatively balancing the trade-off between resolution and image noise separately for TV-PAPA and TV-OSL. However, the authors arrived at the same penalty-weight value for both of them. The authors set the first penalty-weight in HOTV-PAPA equal to the optimal penalty-weight found for TV-PAPA. The second penalty-weight needed for HOTV-PAPA is tuned by balancing resolution and the severity of staircase artifacts. The authors adjust the Gaussian postfilter to approximately match the local point spread function of GPF-EM and HOTV-PAPA. The authors examine hot lesion detectability, study local spatial resolution, analyze background noise properties, estimate mean

  2. High Resolution Thermometry for EXACT

    Science.gov (United States)

    Panek, J. S.; Nash, A. E.; Larson, M.; Mulders, N.

    2000-01-01

    High Resolution Thermometers (HRTs) based on SQUID detection of the magnetization of a paramagnetic salt or a metal alloy has been commonly used for sub-nano Kelvin temperature resolution in low temperature physics experiments. The main applications to date have been for temperature ranges near the lambda point of He-4 (2.177 K). These thermometers made use of materials such as Cu(NH4)2Br4 *2H2O, GdCl3, or PdFe. None of these materials are suitable for EXACT, which will explore the region of the He-3/He-4 tricritical point at 0.87 K. The experiment requirements and properties of several candidate paramagnetic materials will be presented, as well as preliminary test results.

  3. High temperature and high resolution uv photoelectron spectroscopy using supersonic molecular beams

    International Nuclear Information System (INIS)

    Wang, Lai-Sheng; Reutt-Robey, J.E.; Niu, B.; Lee, Y.T.; Shirley, D.A.

    1989-07-01

    A high temperature molecular beam source with electron bombardment heating has been built for high resolution photoelectron spectroscopic studies of high temperature species and clusters. This source has the advantages of: producing an intense, continuous, seeded molecular beam, eliminating the interference of the heating mechanism from the photoelectron measurement. Coupling the source with our hemispherical electron energy analyzer, we can obtain very high resolution HeIα (584 angstrom) photoelectron spectra of high temperature species. Vibrationally-resolved photoelectron spectra of PbSe, As 2 , As 4 , and ZnCl 2 are shown to demonstrate the performance of the new source. 25 refs., 8 figs., 1 tab

  4. Ribbon scanning confocal for high-speed high-resolution volume imaging of brain.

    Directory of Open Access Journals (Sweden)

    Alan M Watson

    Full Text Available Whole-brain imaging is becoming a fundamental means of experimental insight; however, achieving subcellular resolution imagery in a reasonable time window has not been possible. We describe the first application of multicolor ribbon scanning confocal methods to collect high-resolution volume images of chemically cleared brains. We demonstrate that ribbon scanning collects images over ten times faster than conventional high speed confocal systems but with equivalent spectral and spatial resolution. Further, using this technology, we reconstruct large volumes of mouse brain infected with encephalitic alphaviruses and demonstrate that regions of the brain with abundant viral replication were inaccessible to vascular perfusion. This reveals that the destruction or collapse of large regions of brain micro vasculature may contribute to the severe disease caused by Venezuelan equine encephalitis virus. Visualization of this fundamental impact of infection would not be possible without sampling at subcellular resolution within large brain volumes.

  5. High resolution tsunami inversion for 2010 Chile earthquake

    Directory of Open Access Journals (Sweden)

    T.-R. Wu

    2011-12-01

    Full Text Available We investigate the feasibility of inverting high-resolution vertical seafloor displacement from tsunami waveforms. An inversion method named "SUTIM" (small unit tsunami inversion method is developed to meet this goal. In addition to utilizing the conventional least-square inversion, this paper also enhances the inversion resolution by Grid-Shifting method. A smooth constraint is adopted to gain stability. After a series of validation and performance tests, SUTIM is used to study the 2010 Chile earthquake. Based upon data quality and azimuthal distribution, we select tsunami waveforms from 6 GLOSS stations and 1 DART buoy record. In total, 157 sub-faults are utilized for the high-resolution inversion. The resolution reaches 10 sub-faults per wavelength. The result is compared with the distribution of the aftershocks and waveforms at each gauge location with very good agreement. The inversion result shows that the source profile features a non-uniform distribution of the seafloor displacement. The highly elevated vertical seafloor is mainly concentrated in two areas: one is located in the northern part of the epicentre, between 34° S and 36° S; the other is in the southern part, between 37° S and 38° S.

  6. High resolution tsunami inversion for 2010 Chile earthquake

    Science.gov (United States)

    Wu, T.-R.; Ho, T.-C.

    2011-12-01

    We investigate the feasibility of inverting high-resolution vertical seafloor displacement from tsunami waveforms. An inversion method named "SUTIM" (small unit tsunami inversion method) is developed to meet this goal. In addition to utilizing the conventional least-square inversion, this paper also enhances the inversion resolution by Grid-Shifting method. A smooth constraint is adopted to gain stability. After a series of validation and performance tests, SUTIM is used to study the 2010 Chile earthquake. Based upon data quality and azimuthal distribution, we select tsunami waveforms from 6 GLOSS stations and 1 DART buoy record. In total, 157 sub-faults are utilized for the high-resolution inversion. The resolution reaches 10 sub-faults per wavelength. The result is compared with the distribution of the aftershocks and waveforms at each gauge location with very good agreement. The inversion result shows that the source profile features a non-uniform distribution of the seafloor displacement. The highly elevated vertical seafloor is mainly concentrated in two areas: one is located in the northern part of the epicentre, between 34° S and 36° S; the other is in the southern part, between 37° S and 38° S.

  7. Concept for a new high resolution high intensity diffractometer

    Energy Technology Data Exchange (ETDEWEB)

    Stuhr, U [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    A concept of a new time-of-flight powder-diffractometer for a thermal neutral beam tube at SINQ is presented. The design of the instrument optimises the contradictory conditions of high intensity and high resolution. The high intensity is achieved by using many neutron pulses simultaneously. By analysing the time-angle-pattern of the detected neutrons an assignment of the neutrons to a single pulse is possible. (author) 3 figs., tab., refs.

  8. Volumetric expiratory high-resolution CT of the lung

    International Nuclear Information System (INIS)

    Nishino, Mizuki; Hatabu, Hiroto

    2004-01-01

    We developed a volumetric expiratory high-resolution CT (HRCT) protocol that provides combined inspiratory and expiratory volumetric imaging of the lung without increasing radiation exposure, and conducted a preliminary feasibility assessment of this protocol to evaluate diffuse lung disease with small airway abnormalities. The volumetric expiratory high-resolution CT increased the detectability of the conducting airway to the areas of air trapping (P<0.0001), and added significant information about extent and distribution of air trapping (P<0.0001)

  9. Developing Visual Editors for High-Resolution Haptic Patterns

    DEFF Research Database (Denmark)

    Cuartielles, David; Göransson, Andreas; Olsson, Tony

    2012-01-01

    In this article we give an overview of our iterative work in developing visual editors for creating high resolution haptic patterns to be used in wearable, haptic feedback devices. During the past four years we have found the need to address the question of how to represent, construct and edit high...... resolution haptic patterns so that they translate naturally to the user’s haptic experience. To solve this question we have developed and tested several visual editors...

  10. Slip-accumulation patterns and earthquake recurrences along the Talas-Fergana Fault - Contributions of high-resolution geomorphic offsets.

    Science.gov (United States)

    Rizza, M.; Dubois, C.; Fleury, J.; Abdrakhmatov, K.; Pousse, L.; Baikulov, S.; Vezinet, A.

    2017-12-01

    In the western Tien-Shan Range, the largest intracontinental strike-slip fault is the Karatau-Talas Fergana Fault system. This dextral fault system is subdivided into two main segments: the Karatau fault to the north and the Talas-Fergana fault (TFF) to the south. Kinematics and rates of deformation for the TFF during the Quaternary period are still debated and are poorly constrained. Only a few paleoseismological investigations are availabe along the TFF (Burtman et al., 1996; Korjenkov et al., 2010) and no systematic quantifications of the dextral displacements along the TFF has been undertaken. As such, the appraisal of the TFF behavior demands new tectonic information. In this study, we present the first detailed analysis of the morphology and the segmentation of the TFF and an offset inventory of morphological markers along the TFF. To discuss temporal and spatial recurrence patterns of slip accumulated over multiple seismic events, our study focused on a 60 km-long section of the TFF (Chatkal segment). Using tri-stereo Pleiades satellite images, high-resolution DEMs (1*1 m pixel size) have been generated in order to (i) analyze the fine-scale fault geometry and (ii) thoroughly measure geomorphic offsets. Photogrammetry data obtained from our drone survey on high interest sites, provide higher-resolution DEMs of 0.5 * 0.5 m pixel size.Our remote sensing mapping allows an unprecedented subdivision - into five distinct segments - of the study area. About 215 geomorphic markers have been measured and offsets range from 4.5m to 180 m. More than 80% of these offsets are smaller than 60 m, suggesting landscape reset during glacial maximum. Calculations of Cumulative Offset Probability Density (COPD) for the whole 60 km-long section as well as for each segments support distinct behavior from a segment to another and thus variability in slip-accumulation patterns. Our data argue for uniform slip model behavior along this section of the TFF. Moreover, we excavated a

  11. High resolution SETI: Experiences and prospects

    Science.gov (United States)

    Horowitz, Paul; Clubok, Ken

    Megachannel spectroscopy with sub-Hertz resolution constitutes an attractive strategy for a microwave search for extraterrestrial intelligence (SETI), assuming the transmission of a narrowband radiofrequency beacon. Such resolution matches the properties of the interstellar medium, and the necessary Doppler corrections provide a high degree of interference rejection. We have constructed a frequency-agile receiver with an FFT-based 8 megachannel digital spectrum analyzer, on-line signal recognition, and multithreshold archiving. We are using it to conduct a meridian transit search of the northern sky at the Harvard-Smithsonian 26-m antenna, with a second identical system scheduled to begin observations in Argentina this month. Successive 400 kHz spectra, at 0.05 Hz resolution, are searched for features characteristic of an intentional narrowband beacon transmission. These spectra are centered on guessable frequencies (such as λ21 cm), referenced successively to the local standard of rest, the galactic barycenter, and the cosmic blackbody rest frame. This search has rejected interference admirably, but is greatly limited both in total frequency coverage and sensitivity to signals other than carriers. We summarize five years of high resolution SETI at Harvard, in the context of answering the questions "How useful is narrowband SETI, how serious are its limitations, what can be done to circumvent them, and in what direction should SETI evolve?" Increasingly powerful signal processing hardware, combined with ever-higher memory densities, are particularly relevant, permitting the construction of compact and affordable gigachannel spectrum analyzers covering hundreds of megahertz of instantaneous bandwidth.

  12. The high-resolution regional reanalysis COSMO-REA6

    Science.gov (United States)

    Ohlwein, C.

    2016-12-01

    Reanalyses gain more and more importance as a source of meteorological information for many purposes and applications. Several global reanalyses projects (e.g., ERA, MERRA, CSFR, JMA9) produce and verify these data sets to provide time series as long as possible combined with a high data quality. Due to a spatial resolution down to 50-70km and 3-hourly temporal output, they are not suitable for small scale problems (e.g., regional climate assessment, meso-scale NWP verification, input for subsequent models such as river runoff simulations). The implementation of regional reanalyses based on a limited area model along with a data assimilation scheme is able to generate reanalysis data sets with high spatio-temporal resolution. Within the Hans-Ertel-Centre for Weather Research (HErZ), the climate monitoring branch concentrates efforts on the assessment and analysis of regional climate in Germany and Europe. In joint cooperation with DWD (German Meteorological Service), a high-resolution reanalysis system based on the COSMO model has been developed. The regional reanalysis for Europe matches the domain of the CORDEX EURO-11 specifications, albeit at a higher spatial resolution, i.e., 0.055° (6km) instead of 0.11° (12km) and comprises the assimilation of observational data using the existing nudging scheme of COSMO complemented by a special soil moisture analysis with boundary conditions provided by ERA-Interim data. The reanalysis data set covers the past 20 years. Extensive evaluation of the reanalysis is performed using independent observations with special emphasis on precipitation and high-impact weather situations indicating a better representation of small scale variability. Further, the evaluation shows an added value of the regional reanalysis with respect to the forcing ERA Interim reanalysis and compared to a pure high-resolution dynamical downscaling approach without data assimilation.

  13. Dating recent floodplain sediments in the Hawkesbury-Nepean River system, eastern Australia using single-grain quartz OSL

    DEFF Research Database (Denmark)

    Sim, Anna K.; Thomsen, Kristina Jørkov; Murray, K.J.

    2014-01-01

    Two fluvial sediment cores taken from a floodplain of the Hawkesbury-Nepean River system in the Sydney region, eastern Australia are dated using Optically Stimulated Luminescence (OSL) to provide a reliable chronology essential for the management and planning of water resources. Nine charcoal 14C...... in an average apparent age overestimation of ~200 years, which is significant for these samples, but negligible for sediments older than a few thousand years. The intention is that the chronology obtained in this study will be used in conjunction with a proxy flood record, derived from floodplain sediments...

  14. SRS station 16.3: high-resolution applications

    CERN Document Server

    Murphy, B M; Golshan, M; Moore, M; Reid, J; Kowalski, G

    2001-01-01

    Station 16.3 is a high-resolution X-ray diffraction beamline at Daresbury Laboratory Synchrotron Radiation Source. The data presented demonstrate the high-resolution available on the station utilising the recently commissioned four-reflection Si 1 1 1 monochromator and three-reflection Si 1 1 1 analyser. For comparison, a reciprocal space map of the two-bounce Si 1 1 1 monochromator and two-bounce analyser is also shown. Operation of the station is illustrated with examples for silicon, and for diamond. Lattice parameter variations were measured with accuracies in the part per million range and lattice tilts at the arc second level (DuMond, Phys. Rev. 52 (1937) 872).

  15. High-resolution X-ray crystal structure of bovine H-protein using the high-pressure cryocooling method.

    Science.gov (United States)

    Higashiura, Akifumi; Ohta, Kazunori; Masaki, Mika; Sato, Masaru; Inaka, Koji; Tanaka, Hiroaki; Nakagawa, Atsushi

    2013-11-01

    Recently, many technical improvements in macromolecular X-ray crystallography have increased the number of structures deposited in the Protein Data Bank and improved the resolution limit of protein structures. Almost all high-resolution structures have been determined using a synchrotron radiation source in conjunction with cryocooling techniques, which are required in order to minimize radiation damage. However, optimization of cryoprotectant conditions is a time-consuming and difficult step. To overcome this problem, the high-pressure cryocooling method was developed (Kim et al., 2005) and successfully applied to many protein-structure analyses. In this report, using the high-pressure cryocooling method, the X-ray crystal structure of bovine H-protein was determined at 0.86 Å resolution. Structural comparisons between high- and ambient-pressure cryocooled crystals at ultra-high resolution illustrate the versatility of this technique. This is the first ultra-high-resolution X-ray structure obtained using the high-pressure cryocooling method.

  16. Resolution-recovery-embedded image reconstruction for a high-resolution animal SPECT system.

    Science.gov (United States)

    Zeraatkar, Navid; Sajedi, Salar; Farahani, Mohammad Hossein; Arabi, Hossein; Sarkar, Saeed; Ghafarian, Pardis; Rahmim, Arman; Ay, Mohammad Reza

    2014-11-01

    The small-animal High-Resolution SPECT (HiReSPECT) is a dedicated dual-head gamma camera recently designed and developed in our laboratory for imaging of murine models. Each detector is composed of an array of 1.2 × 1.2 mm(2) (pitch) pixelated CsI(Na) crystals. Two position-sensitive photomultiplier tubes (H8500) are coupled to each head's crystal. In this paper, we report on a resolution-recovery-embedded image reconstruction code applicable to the system and present the experimental results achieved using different phantoms and mouse scans. Collimator-detector response functions (CDRFs) were measured via a pixel-driven method using capillary sources at finite distances from the head within the field of view (FOV). CDRFs were then fitted by independent Gaussian functions. Thereafter, linear interpolations were applied to the standard deviation (σ) values of the fitted Gaussians, yielding a continuous map of CDRF at varying distances from the head. A rotation-based maximum-likelihood expectation maximization (MLEM) method was used for reconstruction. A fast rotation algorithm was developed to rotate the image matrix according to the desired angle by means of pre-generated rotation maps. The experiments demonstrated improved resolution utilizing our resolution-recovery-embedded image reconstruction. While the full-width at half-maximum (FWHM) radial and tangential resolution measurements of the system were over 2 mm in nearly all positions within the FOV without resolution recovery, reaching around 2.5 mm in some locations, they fell below 1.8 mm everywhere within the FOV using the resolution-recovery algorithm. The noise performance of the system was also acceptable; the standard deviation of the average counts per voxel in the reconstructed images was 6.6% and 8.3% without and with resolution recovery, respectively. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  17. High-resolution electron microscopy of advanced materials

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, T.E.; Kung, H.H.; Sickafus, K.E.; Gray, G.T. III; Field, R.D.; Smith, J.F. [Los Alamos National Lab., NM (United States). Materials Science and Technology Div.

    1997-11-01

    This final report chronicles a three-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The High-Resolution Electron Microscopy Facility has doubled in size and tripled in quality since the beginning of the three-year period. The facility now includes a field-emission scanning electron microscope, a 100 kV field-emission scanning transmission electron microscope (FE-STEM), a 300 kV field-emission high-resolution transmission electron microscope (FE-HRTEM), and a 300 kV analytical transmission electron microscope. A new orientation imaging microscope is being installed. X-ray energy dispersive spectrometers for chemical analysis are available on all four microscopes; parallel electron energy loss spectrometers are operational on the FE-STEM and FE-HRTEM. These systems enable evaluation of local atomic bonding, as well as chemical composition in nanometer-scale regions. The FE-HRTEM has a point-to-point resolution of 1.6 {angstrom}, but the resolution can be pushed to its information limit of 1 {angstrom} by computer reconstruction of a focal series of images. HRTEM has been used to image the atomic structure of defects such as dislocations, grain boundaries, and interfaces in a variety of materials from superconductors and ferroelectrics to structural ceramics and intermetallics.

  18. High Resolution PET with 250 micrometer LSO Detectors and Adaptive Zoom

    International Nuclear Information System (INIS)

    Cherry, Simon R.; Qi, Jinyi

    2012-01-01

    There have been impressive improvements in the performance of small-animal positron emission tomography (PET) systems since their first development in the mid 1990s, both in terms of spatial resolution and sensitivity, which have directly contributed to the increasing adoption of this technology for a wide range of biomedical applications. Nonetheless, current systems still are largely dominated by the size of the scintillator elements used in the detector. Our research predicts that developing scintillator arrays with an element size of 250 (micro)m or smaller will lead to an image resolution of 500 (micro)m when using 18F- or 64Cu-labeled radiotracers, giving a factor of 4-8 improvement in volumetric resolution over the highest resolution research systems currently in existence. This proposal had two main objectives: (i) To develop and evaluate much higher resolution and efficiency scintillator arrays that can be used in the future as the basis for detectors in a small-animal PET scanner where the spatial resolution is dominated by decay and interaction physics rather than detector size. (ii) To optimize one such high resolution, high sensitivity detector and adaptively integrate it into the existing microPET II small animal PET scanner as a 'zoom-in' detector that provides higher spatial resolution and sensitivity in a limited region close to the detector face. The knowledge gained from this project will provide valuable information for building future PET systems with a complete ring of very high-resolution detector arrays and also lay the foundations for utilizing high-resolution detectors in combination with existing PET systems for localized high-resolution imaging.

  19. Achieving High Resolution Timer Events in Virtualized Environment.

    Science.gov (United States)

    Adamczyk, Blazej; Chydzinski, Andrzej

    2015-01-01

    Virtual Machine Monitors (VMM) have become popular in different application areas. Some applications may require to generate the timer events with high resolution and precision. This however may be challenging due to the complexity of VMMs. In this paper we focus on the timer functionality provided by five different VMMs-Xen, KVM, Qemu, VirtualBox and VMWare. Firstly, we evaluate resolutions and precisions of their timer events. Apparently, provided resolutions and precisions are far too low for some applications (e.g. networking applications with the quality of service). Then, using Xen virtualization we demonstrate the improved timer design that greatly enhances both the resolution and precision of achieved timer events.

  20. Compact and high-resolution optical orbital angular momentum sorter

    Directory of Open Access Journals (Sweden)

    Chenhao Wan

    2017-03-01

    Full Text Available A compact and high-resolution optical orbital angular momentum (OAM sorter is proposed and demonstrated. The sorter comprises a quadratic fan-out mapper and a dual-phase corrector positioned in the pupil plane and the Fourier plane, respectively. The optical system is greatly simplified compared to previous demonstrations of OAM sorting, and the performance in resolution and efficiency is maintained. A folded configuration is set up using a single reflective spatial light modulator (SLM to demonstrate the validity of the scheme. The two phase elements are implemented on the left and right halves of the SLM and connected by a right-angle prism. Experimental results demonstrate the high resolution of the compact OAM sorter, and the current limit in efficiency can be overcome by replacing with transmissive SLMs and removing the beam splitters. This novel scheme paves the way for the miniaturization and integration of high-resolution OAM sorters.

  1. High resolution manometry findings in patients with esophageal epiphrenic diverticula.

    Science.gov (United States)

    Vicentine, Fernando P P; Herbella, Fernando A M; Silva, Luciana C; Patti, Marco G

    2011-12-01

    The pathophysiology of esophageal epiphrenic diverticula is still uncertain even though a concomitant motility disorder is found in the majority of patients in different series. High resolution manometry may allow detection of motor abnormalities in a higher number of patients with esophageal epiphrenic diverticula compared with conventional manometry. This study aims to evaluate the high resolution manometry findings in patients with esophageal epiphrenic diverticula. Nine individuals (mean age 63 ± 10 years, 4 females) with esophageal epiphrenic diverticula underwent high resolution manometry. A single diverticulum was observed in eight patients and multiple diverticula in one. Visual analysis of conventional tracings and color pressure plots for identification of segmental abnormalities was performed by two researchers experienced in high resolution manometry. Upper esophageal sphincter was normal in all patients. Esophageal body was abnormal in eight patients; lower esophageal sphincter was abnormal in seven patients. Named esophageal motility disorders were found in seven patients: achalasia in six, diffuse esophageal spasm in one. In one patient, a segmental hypercontractile zone was noticed with pressure of 196 mm Hg. High resolution manometry demonstrated motor abnormalities in all patients with esophageal epiphrenic diverticula.

  2. Constraining Stochastic Parametrisation Schemes Using High-Resolution Model Simulations

    Science.gov (United States)

    Christensen, H. M.; Dawson, A.; Palmer, T.

    2017-12-01

    Stochastic parametrisations are used in weather and climate models as a physically motivated way to represent model error due to unresolved processes. Designing new stochastic schemes has been the target of much innovative research over the last decade. While a focus has been on developing physically motivated approaches, many successful stochastic parametrisation schemes are very simple, such as the European Centre for Medium-Range Weather Forecasts (ECMWF) multiplicative scheme `Stochastically Perturbed Parametrisation Tendencies' (SPPT). The SPPT scheme improves the skill of probabilistic weather and seasonal forecasts, and so is widely used. However, little work has focused on assessing the physical basis of the SPPT scheme. We address this matter by using high-resolution model simulations to explicitly measure the `error' in the parametrised tendency that SPPT seeks to represent. The high resolution simulations are first coarse-grained to the desired forecast model resolution before they are used to produce initial conditions and forcing data needed to drive the ECMWF Single Column Model (SCM). By comparing SCM forecast tendencies with the evolution of the high resolution model, we can measure the `error' in the forecast tendencies. In this way, we provide justification for the multiplicative nature of SPPT, and for the temporal and spatial scales of the stochastic perturbations. However, we also identify issues with the SPPT scheme. It is therefore hoped these measurements will improve both holistic and process based approaches to stochastic parametrisation. Figure caption: Instantaneous snapshot of the optimal SPPT stochastic perturbation, derived by comparing high-resolution simulations with a low resolution forecast model.

  3. High-resolution flood modeling of urban areas using MSN_Flood

    Directory of Open Access Journals (Sweden)

    Michael Hartnett

    2017-07-01

    Full Text Available Although existing hydraulic models have been used to simulate and predict urban flooding, most of these models are inadequate due to the high spatial resolution required to simulate flows in urban floodplains. Nesting high-resolution subdomains within coarser-resolution models is an efficient solution for enabling simultaneous calculation of flooding due to tides, surges, and high river flows. MSN_Flood has been developed to incorporate moving boundaries around nested domains, permitting alternate flooding and drying along the boundary and in the interior of the domain. Ghost cells adjacent to open boundary cells convert open boundaries, in effect, into internal boundaries. The moving boundary may be multi-segmented and non-continuous, with recirculating flow across the boundary. When combined with a bespoke adaptive interpolation scheme, this approach facilitates a dynamic internal boundary. Based on an alternating-direction semi-implicit finite difference scheme, MSN_Flood was used to hindcast a major flood event in Cork City resulting from the combined pressures of fluvial, tidal, and storm surge processes. The results show that the model is computationally efficient, as the 2-m high-resolution nest is used only in the urban flooded region. Elsewhere, lower-resolution nests are used. The results also show that the model is highly accurate when compared with measured data. The model is capable of incorporating nested sub-domains when the nested boundary is multi-segmented and highly complex with lateral gradients of elevation and velocities. This is a major benefit when modelling urban floodplains at very high resolution.

  4. Reproducible high-resolution multispectral image acquisition in dermatology

    Science.gov (United States)

    Duliu, Alexandru; Gardiazabal, José; Lasser, Tobias; Navab, Nassir

    2015-07-01

    Multispectral image acquisitions are increasingly popular in dermatology, due to their improved spectral resolution which enables better tissue discrimination. Most applications however focus on restricted regions of interest, imaging only small lesions. In this work we present and discuss an imaging framework for high-resolution multispectral imaging on large regions of interest.

  5. Teflon pastille use in high dose dosimetry; Utilizacao de pastilhas de teflon em dosimetria de doses altas

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Maria Ines [Associacao Educacional Nove de Julho (UNINOVE), Sao Paulo, SP (Brazil); Caldas, Linda V.E., E-mail: miteixeira@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-10-26

    This paper study the Teflon, which is used as aglomerant in the confection of dosimetric pastilles, for the viabilization of this material as high dose dosimeter. This paper used the OSL technique for the characterization of dosimetric properties of Teflon. The doses-response curve has been obtained for {sup 60}Co radiation between 100 Gy and 50 kGy, and the OSL answer reproducibility. The preliminary results shown that the Teflon is a material which can be used for high dose dosimetry

  6. High Resolution Energetic X-ray Imager (HREXI)

    Science.gov (United States)

    Grindlay, Jonathan

    We propose to design and build the first imaging hard X-ray detector system that incorporates 3D stacking of closely packed detector readouts in finely-spaced imaging arrays with their required data processing and control electronics. In virtually all imaging astronomical detectors, detector readout is done with flex connectors or connections that are not vertical but rather horizontal , requiring loss of focal plane area. For high resolution pixel detectors needed for high speed event-based X-ray imaging, from low energy applications (CMOS) with focusing X-ray telescopes, to hard X-ray applications with pixelated CZT for large area coded aperture telescopes, this new detector development offers great promise. We propose to extend our previous and current APRA supported ProtoEXIST program that has developed the first large area imaging CZT detectors and demonstrated their astrophysical capabilities on two successful balloon flight to a next generation High Resolution Energetic X-ray Imager (HREXI), which would incorporate microvia technology for the first time to connect the readout ASIC on each CZT crystal directly to its control and data processing system. This 3-dimensional stacking of detector and readout/control system means that large area (>2m2) imaging detector planes for a High Resolution Wide-field hard X-ray telescope can be built with initially greatly reduced detector gaps and ultimately with no gaps. This increases detector area, efficiency, and simplicity of detector integration. Thus higher sensitivity wide-field imagers will be possible at lower cost. HREXI will enable a post-Swift NASA mission such as the EREXS concept proposed to PCOS to be conducted as a future MIDEX mission. This mission would conduct a high resolution (<2 arcmin) , broad band (5 200 keV) hard X-ray survey of black holes on all scales with ~10X higher sensitivity than Swift. In the current era of Time Domain Astrophysics, such a survey capability, in conjunction with a n

  7. High-resolution investigations of edge effects in neutron imaging

    International Nuclear Information System (INIS)

    Strobl, M.; Kardjilov, N.; Hilger, A.; Kuehne, G.; Frei, G.; Manke, I.

    2009-01-01

    Edge enhancement is the main effect measured by the so-called inline or propagation-based neutron phase contrast imaging method. The effect has originally been explained by diffraction, and high spatial coherence has been claimed to be a necessary precondition. However, edge enhancement has also been found in conventional imaging with high resolution. In such cases the effects can produce artefacts and hinder quantification. In this letter the edge effects at cylindrical shaped samples and long straight edges have been studied in detail. The enhancement can be explained by refraction and total reflection. Using high-resolution imaging, where spatial resolutions better than 50 μm could be achieved, refraction and total reflection peaks - similar to diffraction patterns - could be separated and distinguished.

  8. High-Resolution Adaptive Optics Test-Bed for Vision Science

    International Nuclear Information System (INIS)

    Wilks, S.C.; Thomspon, C.A.; Olivier, S.S.; Bauman, B.J.; Barnes, T.; Werner, J.S.

    2001-01-01

    We discuss the design and implementation of a low-cost, high-resolution adaptive optics test-bed for vision research. It is well known that high-order aberrations in the human eye reduce optical resolution and limit visual acuity. However, the effects of aberration-free eyesight on vision are only now beginning to be studied using adaptive optics to sense and correct the aberrations in the eye. We are developing a high-resolution adaptive optics system for this purpose using a Hamamatsu Parallel Aligned Nematic Liquid Crystal Spatial Light Modulator. Phase-wrapping is used to extend the effective stroke of the device, and the wavefront sensing and wavefront correction are done at different wavelengths. Issues associated with these techniques will be discussed

  9. Ultra-high resolution AMOLED

    Science.gov (United States)

    Wacyk, Ihor; Prache, Olivier; Ghosh, Amal

    2011-06-01

    AMOLED microdisplays continue to show improvement in resolution and optical performance, enhancing their appeal for a broad range of near-eye applications such as night vision, simulation and training, situational awareness, augmented reality, medical imaging, and mobile video entertainment and gaming. eMagin's latest development of an HDTV+ resolution technology integrates an OLED pixel of 3.2 × 9.6 microns in size on a 0.18 micron CMOS backplane to deliver significant new functionality as well as the capability to implement a 1920×1200 microdisplay in a 0.86" diagonal area. In addition to the conventional matrix addressing circuitry, the HDTV+ display includes a very lowpower, low-voltage-differential-signaling (LVDS) serialized interface to minimize cable and connector size as well as electromagnetic emissions (EMI), an on-chip set of look-up-tables for digital gamma correction, and a novel pulsewidth- modulation (PWM) scheme that together with the standard analog control provides a total dimming range of 0.05cd/m2 to 2000cd/m2 in the monochrome version. The PWM function also enables an impulse drive mode of operation that significantly reduces motion artifacts in high speed scene changes. An internal 10-bit DAC ensures that a full 256 gamma-corrected gray levels are available across the entire dimming range, resulting in a measured dynamic range exceeding 20-bits. This device has been successfully tested for operation at frame rates ranging from 30Hz up to 85Hz. This paper describes the operational features and detailed optical and electrical test results for the new AMOLED WUXGA resolution microdisplay.

  10. Generalized Nonlinear Chirp Scaling Algorithm for High-Resolution Highly Squint SAR Imaging.

    Science.gov (United States)

    Yi, Tianzhu; He, Zhihua; He, Feng; Dong, Zhen; Wu, Manqing

    2017-11-07

    This paper presents a modified approach for high-resolution, highly squint synthetic aperture radar (SAR) data processing. Several nonlinear chirp scaling (NLCS) algorithms have been proposed to solve the azimuth variance of the frequency modulation rates that are caused by the linear range walk correction (LRWC). However, the azimuth depth of focusing (ADOF) is not handled well by these algorithms. The generalized nonlinear chirp scaling (GNLCS) algorithm that is proposed in this paper uses the method of series reverse (MSR) to improve the ADOF and focusing precision. It also introduces a high order processing kernel to avoid the range block processing. Simulation results show that the GNLCS algorithm can enlarge the ADOF and focusing precision for high-resolution highly squint SAR data.

  11. Generalized Nonlinear Chirp Scaling Algorithm for High-Resolution Highly Squint SAR Imaging

    Directory of Open Access Journals (Sweden)

    Tianzhu Yi

    2017-11-01

    Full Text Available This paper presents a modified approach for high-resolution, highly squint synthetic aperture radar (SAR data processing. Several nonlinear chirp scaling (NLCS algorithms have been proposed to solve the azimuth variance of the frequency modulation rates that are caused by the linear range walk correction (LRWC. However, the azimuth depth of focusing (ADOF is not handled well by these algorithms. The generalized nonlinear chirp scaling (GNLCS algorithm that is proposed in this paper uses the method of series reverse (MSR to improve the ADOF and focusing precision. It also introduces a high order processing kernel to avoid the range block processing. Simulation results show that the GNLCS algorithm can enlarge the ADOF and focusing precision for high-resolution highly squint SAR data.

  12. Human enamel structure studied by high resolution electron microscopy

    International Nuclear Information System (INIS)

    Wen, S.L.

    1989-01-01

    Human enamel structural features are characterized by high resolution electron microscopy. The human enamel consists of polycrystals with a structure similar to Ca10(PO4)6(OH)2. This article describes the structural features of human enamel crystal at atomic and nanometer level. Besides the structural description, a great number of high resolution images are included. Research into the carious process in human enamel is very important for human beings. This article firstly describes the initiation of caries in enamel crystal at atomic and unit-cell level and secondly describes the further steps of caries with structural and chemical demineralization. The demineralization in fact, is the origin of caries in human enamel. The remineralization of carious areas in human enamel has drawn more and more attention as its potential application is realized. This process has been revealed by high resolution electron microscopy in detail in this article. On the other hand, the radiation effects on the structure of human enamel are also characterized by high resolution electron microscopy. In order to reveal this phenomenon clearly, a great number of electron micrographs have been shown, and a physical mechanism is proposed. 26 references

  13. Refinement procedure for the image alignment in high-resolution electron tomography

    International Nuclear Information System (INIS)

    Houben, L.; Bar Sadan, M.

    2011-01-01

    High-resolution electron tomography from a tilt series of transmission electron microscopy images requires an accurate image alignment procedure in order to maximise the resolution of the tomogram. This is the case in particular for ultra-high resolution where even very small misalignments between individual images can dramatically reduce the fidelity of the resultant reconstruction. A tomographic-reconstruction based and marker-free method is proposed, which uses an iterative optimisation of the tomogram resolution. The method utilises a search algorithm that maximises the contrast in tomogram sub-volumes. Unlike conventional cross-correlation analysis it provides the required correlation over a large tilt angle separation and guarantees a consistent alignment of images for the full range of object tilt angles. An assessment based on experimental reconstructions shows that the marker-free procedure is competitive to the reference of marker-based procedures at lower resolution and yields sub-pixel accuracy even for simulated high-resolution data. -- Highlights: → Alignment procedure for electron tomography based on iterative tomogram contrast optimisation. → Marker-free, independent of object, little user interaction. → Accuracy competitive with fiducial marker methods and suited for high-resolution tomography.

  14. High resolution backscattering instruments

    International Nuclear Information System (INIS)

    Coldea, R.

    2001-01-01

    The principle of operation of indirect-geometry time-of-flight spectrometers are presented, including the IRIS at the ISIS spallation neutron source. The key features that make those types of spectrometers ideally suited for low-energy spectroscopy are: high energy resolution over a wide dynamic range, and simultaneous measurement over a large momentum transfer range provided by the wide angular detector coverage. To exemplify these features are discussed of single-crystal experiments of the spin dynamics in the two-dimensional frustrated quantum magnet Cs 2 CuCl 4 . (R.P.)

  15. Using Adobe Acrobat to create high-resolution line art images.

    Science.gov (United States)

    Woo, Hyoun Sik; Lee, Jeong Min

    2009-08-01

    The purpose of this article is to introduce a method for using Adobe Acrobat to make high-resolution and high-quality line art images. High-resolution and high-quality line art images for radiology journal submission can be generated using Adobe Acrobat as a steppingstone, and the customized PDF conversion settings can be used for converting hybrid images, including both bitmap and vector components.

  16. High-resolution axial MR imaging of tibial stress injuries

    Directory of Open Access Journals (Sweden)

    Mammoto Takeo

    2012-05-01

    Full Text Available Abstract Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries.

  17. High-resolution axial MR imaging of tibial stress injuries

    Science.gov (United States)

    2012-01-01

    Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries. PMID:22574840

  18. High-resolution esophageal pressure topography for esophageal motility disorders

    OpenAIRE

    Hashem Fakhre Yaseri; Gholamreza Hamsi; Tayeb Ramim

    2016-01-01

    Background: High-resolution manometer (HRM) of the esophagus has become the main diagnostic test in the evaluation of esophageal motility disorders. The development of high-resolution manometry catheters and software displays of manometry recordings in color-coded pressure plots have changed the diagnostic assessment of esophageal disease. The first step of the Chicago classification described abnormal esophagogastric junction deglutitive relaxation. The latest classification system, proposed...

  19. Quantitation of Acrylamide in Foods by High-Resolution Mass Spectrometry

    NARCIS (Netherlands)

    Troise, A.D.; Fogliano, Vincenzo

    2016-01-01

    The use of liquid chromatography high-resolution mass spectrometry (LC-HRMS) and direct analysis real-time high-resolution mass spectrometry (DART-HRMS) defines a new scenario in the analysis of thermal-induced toxicants, such as acrylamide. Several factors contribute to the definition of the

  20. High-spin research with HERA [High Energy-Resolution Array

    International Nuclear Information System (INIS)

    Diamond, R.M.

    1987-06-01

    The topic of this report is high spin research with the High Energy Resolution Array (HERA) at Lawrence Berkeley Laboratory. This is a 21 Ge detector system, the first with bismuth germanate (BGO) Compton suppression. The array is described briefly and some of the results obtained during the past year using this detector facility are discussed. Two types of studies are described: observation of superdeformation in the light Nd isotopes, and rotational damping at high spin and excitation energy in the continuum gamma ray spectrum

  1. Ultra high resolution soft x-ray tomography

    International Nuclear Information System (INIS)

    Haddad, W.S.; Trebes, J.E.; Goodman, D.M.

    1995-01-01

    Ultra high resolution three dimensional images of a microscopic test object were made with soft x-rays using a scanning transmission x-ray microscope. The test object consisted of two different patterns of gold bars on silicon nitride windows that were separated by ∼5μm. A series of nine 2-D images of the object were recorded at angles between -50 to +55 degrees with respect to the beam axis. The projections were then combined tomographically to form a 3-D image by means of an algebraic reconstruction technique (ART) algorithm. A transverse resolution of ∼1000 Angstrom was observed. Artifacts in the reconstruction limited the overall depth resolution to ∼6000 Angstrom, however some features were clearly reconstructed with a depth resolution of ∼1000 Angstrom. A specially modified ART algorithm and a constrained conjugate gradient (CCG) code were also developed as improvements over the standard ART algorithm. Both of these methods made significant improvements in the overall depth resolution bringing it down to ∼1200 Angstrom overall. Preliminary projection data sets were also recorded with both dry and re-hydrated human sperm cells over a similar angular range

  2. Ultra high resolution soft x-ray tomography

    International Nuclear Information System (INIS)

    Haddad, W.S.; Trebes, J.E.; Goodman, D.M.; Lee, H.R.; McNulty, I.; Zalensky, A.O.

    1995-01-01

    Ultra high resolution three dimensional images of a microscopic test object were made with soft x-rays using a scanning transmission x-ray microscope. The test object consisted of two different patterns of gold bars on silicon nitride windows that were separated by ∼5 microm. A series of nine 2-D images of the object were recorded at angles between -50 to +55 degrees with respect to the beam axis. The projections were then combined tomographically to form a 3-D image by means of an algebraic reconstruction technique (ART) algorithm. A transverse resolution of ∼ 1,000 angstrom was observed. Artifacts in the reconstruction limited the overall depth resolution to ∼ 6,000 angstrom, however some features were clearly reconstructed with a depth resolution of ∼ 1,000 angstrom. A specially modified ART algorithm and a constrained conjugate gradient (CCG) code were also developed as improvements over the standard ART algorithm. Both of these methods made significant improvements in the overall depth resolution, bringing it down to ∼ 1,200 angstrom overall. Preliminary projection data sets were also recorded with both dry and re-hydrated human sperm cells over a similar angular range

  3. High-resolution 3D imaging of polymerized photonic crystals by lab-based x-ray nanotomography with 50-nm resolution

    Science.gov (United States)

    Yin, Leilei; Chen, Ying-Chieh; Gelb, Jeff; Stevenson, Darren M.; Braun, Paul A.

    2010-09-01

    High resolution x-ray computed tomography is a powerful non-destructive 3-D imaging method. It can offer superior resolution on objects that are opaque or low contrast for optical microscopy. Synchrotron based x-ray computed tomography systems have been available for scientific research, but remain difficult to access for broader users. This work introduces a lab-based high-resolution x-ray nanotomography system with 50nm resolution in absorption and Zernike phase contrast modes. Using this system, we have demonstrated high quality 3-D images of polymerized photonic crystals which have been analyzed for band gap structures. The isotropic volumetric data shows excellent consistency with other characterization results.

  4. High-resolution nuclear magnetic resonance studies of proteins.

    Science.gov (United States)

    Jonas, Jiri

    2002-03-25

    The combination of advanced high-resolution nuclear magnetic resonance (NMR) techniques with high-pressure capability represents a powerful experimental tool in studies of protein folding. This review is organized as follows: after a general introduction of high-pressure, high-resolution NMR spectroscopy of proteins, the experimental part deals with instrumentation. The main section of the review is devoted to NMR studies of reversible pressure unfolding of proteins with special emphasis on pressure-assisted cold denaturation and the detection of folding intermediates. Recent studies investigating local perturbations in proteins and the experiments following the effects of point mutations on pressure stability of proteins are also discussed. Ribonuclease A, lysozyme, ubiquitin, apomyoglobin, alpha-lactalbumin and troponin C were the model proteins investigated.

  5. High-resolution CT of the lungs: Anatomic-pathologic correlation

    International Nuclear Information System (INIS)

    Stein, M.G.; Webb, W.R.; Finkbeiner, W.; Gamsu, G.

    1986-01-01

    The interpretation of thin-section (1.5-mm), high-resolution CT scans of the lungs has been limited by lack of direct radiologic and pathologic correlation. The author scanned fresh inflated isolated lungs from ten healthy and five diseased subjects using thin-section, high-resolution techniques. The lungs were then fixed by inflation with endobronchial Formalin. Gough sections (1 mm thick) were obtained at the same levels as the CT scans. In healthy subjects, secondary lobules were identified by the presence of visible interlobular septa and central arterioles. In some patients with disease, septal thickening was visible. In patients with honeycombing cystic areas of destroyed lung were seen, along with areas of fibrosis. Emphysema was well evaluated. Thin-section, high-resolution CT can define lung architecture and may resolve mild changes of the interstitium

  6. High-resolution x-ray imaging using a structured scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Hormozan, Yashar, E-mail: hormozan@kth.se; Sychugov, Ilya; Linnros, Jan [Materials and Nano Physics, School of Information and Communication Technology, KTH Royal Institute of Technology, Electrum 229, Kista, Stockholm SE-16440 (Sweden)

    2016-02-15

    Purpose: In this study, the authors introduce a new generation of finely structured scintillators with a very high spatial resolution (a few micrometers) compared to conventional scintillators, yet maintaining a thick absorbing layer for improved detectivity. Methods: Their concept is based on a 2D array of high aspect ratio pores which are fabricated by ICP etching, with spacings (pitches) of a few micrometers, on silicon and oxidation of the pore walls. The pores were subsequently filled by melting of powdered CsI(Tl), as the scintillating agent. In order to couple the secondary emitted photons of the back of the scintillator array to a CCD device, having a larger pixel size than the pore pitch, an open optical microscope with adjustable magnification was designed and implemented. By imaging a sharp edge, the authors were able to calculate the modulation transfer function (MTF) of this finely structured scintillator. Results: The x-ray images of individually resolved pores suggest that they have been almost uniformly filled, and the MTF measurements show the feasibility of a few microns spatial resolution imaging, as set by the scintillator pore size. Compared to existing techniques utilizing CsI needles as a structured scintillator, their results imply an almost sevenfold improvement in resolution. Finally, high resolution images, taken by their detector, are presented. Conclusions: The presented work successfully shows the functionality of their detector concept for high resolution imaging and further fabrication developments are most likely to result in higher quantum efficiencies.

  7. Science with High Spatial Resolution Far-Infrared Data

    Science.gov (United States)

    Terebey, Susan (Editor); Mazzarella, Joseph M. (Editor)

    1994-01-01

    The goal of this workshop was to discuss new science and techniques relevant to high spatial resolution processing of far-infrared data, with particular focus on high resolution processing of IRAS data. Users of the maximum correlation method, maximum entropy, and other resolution enhancement algorithms applicable to far-infrared data gathered at the Infrared Processing and Analysis Center (IPAC) for two days in June 1993 to compare techniques and discuss new results. During a special session on the third day, interested astronomers were introduced to IRAS HIRES processing, which is IPAC's implementation of the maximum correlation method to the IRAS data. Topics discussed during the workshop included: (1) image reconstruction; (2) random noise; (3) imagery; (4) interacting galaxies; (5) spiral galaxies; (6) galactic dust and elliptical galaxies; (7) star formation in Seyfert galaxies; (8) wavelet analysis; and (9) supernova remnants.

  8. Textural Segmentation of High-Resolution Sidescan Sonar Images

    National Research Council Canada - National Science Library

    Kalcic, Maria; Bibee, Dale

    1995-01-01

    .... The high resolution of the 455 kHz sonar imagery also provides much information about the surficial bottom sediments, however their acoustic scattering properties are not well understood at high frequencies...

  9. High-resolution computed tomography findings in pulmonary Langerhans cell histiocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Rosana Souza [Universidade Federal do Rio de Janeiro (HUCFF/UFRJ), RJ (Brazil). Hospital Universitario Clementino Fraga Filho. Unit of Radiology; Capone, Domenico; Ferreira Neto, Armando Leao [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil)

    2011-07-15

    Objective: The present study was aimed at characterizing main lung changes observed in pulmonary Langerhans cell histiocytosis by means of high-resolution computed tomography. Materials and Methods: High-resolution computed tomography findings in eight patients with proven disease diagnosed by open lung biopsy, immunohistochemistry studies and/or extrapulmonary manifestations were retrospectively evaluated. Results: Small rounded, thin-walled cystic lesions were observed in the lung of all the patients. Nodules with predominantly peripheral distribution over the lung parenchyma were observed in 75% of the patients. The lesions were diffusely distributed, predominantly in the upper and middle lung fields in all of the cases, but involvement of costophrenic angles was observed in 25% of the patients. Conclusion: Comparative analysis of high-resolution computed tomography and chest radiography findings demonstrated that thinwalled cysts and small nodules cannot be satisfactorily evaluated by conventional radiography. Because of its capacity to detect and characterize lung cysts and nodules, high-resolution computed tomography increases the probability of diagnosing pulmonary Langerhans cell histiocytosis. (author)

  10. Luminescence dating of Pleistocene alluvial sediments affected by the Alhama de Murcia fault (eastern Betics, Spain) – a comparison between OSL, IRSL and post-IRIRSL ages

    DEFF Research Database (Denmark)

    Sohbati, Reza; Murray, Andrew S.; Buylaert, Jan-Pieter

    2012-01-01

    The ages of nine alluvial units, identified by the integration of data obtained from five trenches at the southern termination of the Alhama de Murcia Fault (AMF) (eastern Betics, Spain), are constrained using luminescence dating based on the Optically Stimulated Luminescence (OSL) from quartz...

  11. A Forward-Looking High-Resolution GPR System

    National Research Council Canada - National Science Library

    Kositsky, Joel; Milanfar, Peyman

    1999-01-01

    A high-resolution ground penetrating radar (GPR) system was designed to help define the optimal radar parameters needed for the efficient standoff detection of buried and surface-laid antitank mines...

  12. Accelerated high-resolution photoacoustic tomography via compressed sensing

    Science.gov (United States)

    Arridge, Simon; Beard, Paul; Betcke, Marta; Cox, Ben; Huynh, Nam; Lucka, Felix; Ogunlade, Olumide; Zhang, Edward

    2016-12-01

    Current 3D photoacoustic tomography (PAT) systems offer either high image quality or high frame rates but are not able to deliver high spatial and temporal resolution simultaneously, which limits their ability to image dynamic processes in living tissue (4D PAT). A particular example is the planar Fabry-Pérot (FP) photoacoustic scanner, which yields high-resolution 3D images but takes several minutes to sequentially map the incident photoacoustic field on the 2D sensor plane, point-by-point. However, as the spatio-temporal complexity of many absorbing tissue structures is rather low, the data recorded in such a conventional, regularly sampled fashion is often highly redundant. We demonstrate that combining model-based, variational image reconstruction methods using spatial sparsity constraints with the development of novel PAT acquisition systems capable of sub-sampling the acoustic wave field can dramatically increase the acquisition speed while maintaining a good spatial resolution: first, we describe and model two general spatial sub-sampling schemes. Then, we discuss how to implement them using the FP interferometer and demonstrate the potential of these novel compressed sensing PAT devices through simulated data from a realistic numerical phantom and through measured data from a dynamic experimental phantom as well as from in vivo experiments. Our results show that images with good spatial resolution and contrast can be obtained from highly sub-sampled PAT data if variational image reconstruction techniques that describe the tissues structures with suitable sparsity-constraints are used. In particular, we examine the use of total variation (TV) regularization enhanced by Bregman iterations. These novel reconstruction strategies offer new opportunities to dramatically increase the acquisition speed of photoacoustic scanners that employ point-by-point sequential scanning as well as reducing the channel count of parallelized schemes that use detector arrays.

  13. A Very High Spatial Resolution Detector for Small Animal PET

    International Nuclear Information System (INIS)

    Kanai Shah, M.S.

    2007-01-01

    Positron Emission Tomography (PET) is an in vivo analog of autoradiography and has the potential to become a powerful new tool in imaging biological processes in small laboratory animals. PET imaging of small animals can provide unique information that can help in advancement of human disease models as well as drug development. Clinical PET scanners used for human imaging are bulky, expensive and do not have adequate spatial resolution for small animal studies. Hence, dedicated, low cost instruments are required for conducting small animal studies with higher spatial resolution than what is currently achieved with clinical as well as dedicated small animal PET scanners. The goal of the proposed project is to investigate a new all solid-state detector design for small animal PET imaging. Exceptionally high spatial resolution, good timing resolution, and excellent energy resolution are expected from the proposed detector design. The Phase I project was aimed at demonstrating the feasibility of producing high performance solid-state detectors that provide high sensitivity, spatial resolution, and timing characteristics. Energy resolution characteristics of the new detector were also investigated. The goal of the Phase II project is to advance the promising solid-state detector technology for small animal PET and determine its full potential. Detectors modules will be built and characterized and finally, a bench-top small animal PET system will be assembled and evaluated

  14. Strengthening IAEA safeguards using high-resolution commercial satellite imagery

    International Nuclear Information System (INIS)

    Zhang Hui

    2001-01-01

    Full text: In May 1997, the IAEA Board of Governors adopted the Additional Safeguards Protocol to improve its ability to detect the undeclared production of fissile material. This new strengthened safeguards system has opened the door for the IAEA to use of all types of information, including the potential use of commercial satellite imagery. We have therefore been investigating the feasibility of strengthening IAEA safeguards using commercial satellite imagery. Based on our analysis on a number of one-meter resolution IKONOS satellite images of military nuclear production facilities at nuclear states including Russia, China, India, Pakistan and Israel, we found that the new high-resolution commercial satellite imagery would play a new and valuable role in strengthening IAEA safeguards. Since 1999, images with a resolution of one meter have been available commercially from Space Imaging's IKONOS satellite. One-meter images from other companies are expected to enter the market soon. Although still an order of magnitude less capable than military imaging satellites, the capabilities of these new high-resolution commercial satellites are good enough to detect and identify the major visible characteristics of nuclear production facilities and sites. Unlike the classified spy satellite photos limited to few countries, the commercial satellite imagery is commercially available to anyone who wants to purchase it. Therefore, the new commercial satellite open a new chance that each state, international organizations, and non-governmental groups could use the commercial images to play a more proactive role in monitoring the nuclear activities in related countries and verifying the compliance of non-proliferation agreements. This could help galvanize support for intensified efforts to slow the pace of nuclear proliferation. To produce fissile materials (plutonium and highly enriched uranium) for weapons, a country would operate dedicated plutonium-production reactors and the

  15. Processing method for high resolution monochromator

    International Nuclear Information System (INIS)

    Kiriyama, Koji; Mitsui, Takaya

    2006-12-01

    A processing method for high resolution monochromator (HRM) has been developed at Japanese Atomic Energy Agency/Quantum Beam Science Directorate/Synchrotron Radiation Research unit at SPring-8. For manufacturing a HRM, a sophisticated slicing machine and X-ray diffractometer have been installed for shaping a crystal ingot and orienting precisely the surface of a crystal ingot, respectively. The specification of the slicing machine is following; Maximum size of a diamond blade is φ 350mm in diameter, φ 38.1mm in the spindle diameter, and 2mm in thickness. A large crystal such as an ingot with 100mm in diameter, 200mm in length can be cut. Thin crystal samples such as a wafer can be also cut using by another sample holder. Working distance of a main shaft with the direction perpendicular to working table in the machine is 350mm at maximum. Smallest resolution of the main shaft with directions of front-and-back and top-and-bottom are 0.001mm read by a digital encoder. 2mm/min can set for cutting samples in the forward direction. For orienting crystal faces relative to the blade direction adjustment, a one-circle goniometer and 2-circle segment are equipped on the working table in the machine. A rotation and a tilt of the stage can be done by manual operation. Digital encoder in a turn stage is furnished and has angle resolution of less than 0.01 degrees. In addition, a hand drill as a supporting device for detailed processing of crystal is prepared. Then, an ideal crystal face can be cut from crystal samples within an accuracy of about 0.01 degrees. By installation of these devices, a high energy resolution monochromator crystal for inelastic x-ray scattering and a beam collimator are got in hand and are expected to be used for nanotechnology studies. (author)

  16. High-resolution coded-aperture design for compressive X-ray tomography using low resolution detectors

    Science.gov (United States)

    Mojica, Edson; Pertuz, Said; Arguello, Henry

    2017-12-01

    One of the main challenges in Computed Tomography (CT) is obtaining accurate reconstructions of the imaged object while keeping a low radiation dose in the acquisition process. In order to solve this problem, several researchers have proposed the use of compressed sensing for reducing the amount of measurements required to perform CT. This paper tackles the problem of designing high-resolution coded apertures for compressed sensing computed tomography. In contrast to previous approaches, we aim at designing apertures to be used with low-resolution detectors in order to achieve super-resolution. The proposed method iteratively improves random coded apertures using a gradient descent algorithm subject to constraints in the coherence and homogeneity of the compressive sensing matrix induced by the coded aperture. Experiments with different test sets show consistent results for different transmittances, number of shots and super-resolution factors.

  17. Refinement procedure for the image alignment in high-resolution electron tomography.

    Science.gov (United States)

    Houben, L; Bar Sadan, M

    2011-01-01

    High-resolution electron tomography from a tilt series of transmission electron microscopy images requires an accurate image alignment procedure in order to maximise the resolution of the tomogram. This is the case in particular for ultra-high resolution where even very small misalignments between individual images can dramatically reduce the fidelity of the resultant reconstruction. A tomographic-reconstruction based and marker-free method is proposed, which uses an iterative optimisation of the tomogram resolution. The method utilises a search algorithm that maximises the contrast in tomogram sub-volumes. Unlike conventional cross-correlation analysis it provides the required correlation over a large tilt angle separation and guarantees a consistent alignment of images for the full range of object tilt angles. An assessment based on experimental reconstructions shows that the marker-free procedure is competitive to the reference of marker-based procedures at lower resolution and yields sub-pixel accuracy even for simulated high-resolution data. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Towards high resolution polarisation analysis using double polarisation and ellipsoidal analysers

    CERN Document Server

    Martin-Y-Marero, D

    2002-01-01

    Classical polarisation analysis methods lack the combination of high resolution and high count rate necessary to cope with the demand of modern condensed-matter experiments. In this work, we present a method to achieve high resolution polarisation analysis based on a double polarisation system. Coupling this method with an ellipsoidal wavelength analyser, a high count rate can be achieved whilst delivering a resolution of around 10 mu eV. This method is ideally suited to pulsed sources, although it can be adapted to continuous sources as well. (orig.)

  19. Ultra-high resolution HLA genotyping and allele discovery by highly multiplexed cDNA amplicon pyrosequencing

    Directory of Open Access Journals (Sweden)

    Lank Simon M

    2012-08-01

    Full Text Available Abstract Background High-resolution HLA genotyping is a critical diagnostic and research assay. Current methods rarely achieve unambiguous high-resolution typing without making population-specific frequency inferences due to a lack of locus coverage and difficulty in exon-phase matching. Achieving high-resolution typing is also becoming more challenging with traditional methods as the database of known HLA alleles increases. Results We designed a cDNA amplicon-based pyrosequencing method to capture 94% of the HLA class I open-reading-frame with only two amplicons per sample, and an analogous method for class II HLA genes, with a primary focus on sequencing the DRB loci. We present a novel Galaxy server-based analysis workflow for determining genotype. During assay validation, we performed two GS Junior sequencing runs to determine the accuracy of the HLA class I amplicons and DRB amplicon at different levels of multiplexing. When 116 amplicons were multiplexed, we unambiguously resolved 99%of class I alleles to four- or six-digit resolution, as well as 100% unambiguous DRB calls. The second experiment, with 271 multiplexed amplicons, missed some alleles, but generated high-resolution, concordant typing for 93% of class I alleles, and 96% for DRB1 alleles. In a third, preliminary experiment we attempted to sequence novel amplicons for other class II loci with mixed success. Conclusions The presented assay is higher-throughput and higher-resolution than existing HLA genotyping methods, and suitable for allele discovery or large cohort sampling. The validated class I and DRB primers successfully generated unambiguously high-resolution genotypes, while further work is needed to validate additional class II genotyping amplicons.

  20. Transistor reset preamplifier for high-rate high-resolution spectroscopy

    International Nuclear Information System (INIS)

    Landis, D.A.; Cork, C.P.; Madden, N.W.; Goulding, F.S.

    1981-10-01

    Pulsed transistor reset of high resolution charge sensitive preamplifiers used in cooled semiconductor spectrometers can sometimes have an advantage over pulsed light reset systems. Several versions of transistor reset spectrometers using both silicon and germanium detectors have been built. This paper discusses the advantages of the transistor reset system and illustrates several configurations of the packages used for the FET and reset transistor. It also describes the preamplifer circuit and shows the performance of the spectrometer at high rates

  1. Constructing a WISE High Resolution Galaxy Atlas

    Science.gov (United States)

    Jarrett, T. H.; Masci, F.; Tsai, C. W.; Petty, S.; Cluver, M.; Assef, Roberto J.; Benford, D.; Blain, A.; Bridge, C.; Donoso, E.; hide

    2012-01-01

    After eight months of continuous observations, the Wide-field Infrared Survey Explorer (WISE) mapped the entire sky at 3.4 micron, 4.6 micron, 12 micron, and 22 micron. We have begun a dedicated WISE High Resolution Galaxy Atlas project to fully characterize large, nearby galaxies and produce a legacy image atlas and source catalog. Here we summarize the deconvolution techniques used to significantly improve the spatial resolution of WISE imaging, specifically designed to study the internal anatomy of nearby galaxies. As a case study, we present results for the galaxy NGC 1566, comparing the WISE enhanced-resolution image processing to that of Spitzer, Galaxy Evolution Explorer, and ground-based imaging. This is the first paper in a two-part series; results for a larger sample of nearby galaxies are presented in the second paper.

  2. High resolution spectroscopy in the microwave and far infrared

    Science.gov (United States)

    Pickett, Herbert M.

    1990-01-01

    High resolution rotational spectroscopy has long been central to remote sensing techniques in atmospheric sciences and astronomy. As such, laboratory measurements must supply the required data to make direct interpretation of data for instruments which sense atmospheres using rotational spectra. Spectral measurements in the microwave and far infrared regions are also very powerful tools when combined with infrared measurements for characterizing the rotational structure of vibrational spectra. In the past decade new techniques were developed which have pushed high resolution spectroscopy into the wavelength region between 25 micrometers and 2 mm. Techniques to be described include: (1) harmonic generation of microwave sources, (2) infrared laser difference frequency generation, (3) laser sideband generation, and (4) ultrahigh resolution interferometers.

  3. High resolution and high speed positron emission tomography data acquisition

    International Nuclear Information System (INIS)

    Burgiss, S.G.; Byars, L.G.; Jones, W.F.; Casey, M.E.

    1986-01-01

    High resolution positron emission tomography (PET) requires many detectors. Thus, data collection systems for PET must have high data rates, wide data paths, and large memories to histogram the events. This design uses the VMEbus to cost effectively provide these features. It provides for several modes of operation including real time sorting, list mode data storage, and replay of stored list mode data

  4. Ultra high spatial and temporal resolution breast imaging at 7T.

    Science.gov (United States)

    van de Bank, B L; Voogt, I J; Italiaander, M; Stehouwer, B L; Boer, V O; Luijten, P R; Klomp, D W J

    2013-04-01

    There is a need to obtain higher specificity in the detection of breast lesions using MRI. To address this need, Dynamic Contrast-Enhanced (DCE) MRI has been combined with other structural and functional MRI techniques. Unfortunately, owing to time constraints structural images at ultra-high spatial resolution can generally not be obtained during contrast uptake, whereas the relatively low spatial resolution of functional imaging (e.g. diffusion and perfusion) limits the detection of small lesions. To be able to increase spatial as well as temporal resolution simultaneously, the sensitivity of MR detection needs to increase as well as the ability to effectively accelerate the acquisition. The required gain in signal-to-noise ratio (SNR) can be obtained at 7T, whereas acceleration can be obtained with high-density receiver coil arrays. In this case, morphological imaging can be merged with DCE-MRI, and other functional techniques can be obtained at higher spatial resolution, and with less distortion [e.g. Diffusion Weighted Imaging (DWI)]. To test the feasibility of this concept, we developed a unilateral breast coil for 7T. It comprises a volume optimized dual-channel transmit coil combined with a 30-channel receive array coil. The high density of small coil elements enabled efficient acceleration in any direction to acquire ultra high spatial resolution MRI of close to 0.6 mm isotropic detail within a temporal resolution of 69 s, high spatial resolution MRI of 1.5 mm isotropic within an ultra high temporal resolution of 6.7 s and low distortion DWI at 7T, all validated in phantoms, healthy volunteers and a patient with a lesion in the right breast classified as Breast Imaging Reporting and Data System (BI-RADS) IV. Copyright © 2012 John Wiley & Sons, Ltd.

  5. High-Resolution X-ray Emission and X-ray Absorption Spectroscopy

    NARCIS (Netherlands)

    Groot, F.M.F. de

    2000-01-01

    In this review, high-resolution X-ray emission and X-ray absorption spectroscopy will be discussed. The focus is on the 3d transition-metal systems. To understand high-resolution X-ray emission and reso-nant X-ray emission, it is first necessary to spend some time discussing the X-ray absorption

  6. High-resolution flurescence spectroscopy in immunoanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Grubor, Nenad M. [Iowa State Univ., Ames, IA (United States)

    2005-01-01

    The work presented in this dissertation combines highly sensitive and selective fluorescence line-narrowing spectroscopy (FLNS) detection with various modes of immunoanalytical techniques. It has been shown that FLNS is capable of directly probing molecules immunocomplexed with antibodies, eliminating analytical ambiguities that may arise from interferences that accompany traditional immunochemical techniques. Moreover, the utilization of highly cross-reactive antibodies for highly specific analyte determination has been demonstrated. Finally, they demonstrate the first example of the spectral resolution of diastereomeric analytes based on their interaction with a cross-reactive antibody.

  7. Development of a high-resolution cavity-beam position monitor

    Directory of Open Access Journals (Sweden)

    Yoichi Inoue

    2008-06-01

    Full Text Available We have developed a high-resolution cavity-beam position monitor (BPM to be used at the focal point of the ATF2, which is a test beam line that is now being built to demonstrate stable orbit control at ∼nanometer resolution. The design of the cavity structure was optimized for the Accelerator Test Facility (ATF beam in various ways. For example, the cavity has a rectangular shape in order to isolate two dipole modes in orthogonal directions, and a relatively thin gap that is less sensitive to trajectory inclination. A two stage homodyne mixer with highly sensitive electronics and phase-sensitive detection was also developed. Two BPM blocks, each containing two cavity BPMs, were installed in the existing ATF beam line using a rigid support frame. After testing the basic characteristics, we measured the resolution using three BPMs. The system demonstrated 8.7 nm position resolution over a dynamic range of 5  μm.

  8. Development of a high-resolution cavity-beam position monitor

    Science.gov (United States)

    Inoue, Yoichi; Hayano, Hitoshi; Honda, Yosuke; Takatomi, Toshikazu; Tauchi, Toshiaki; Urakawa, Junji; Komamiya, Sachio; Nakamura, Tomoya; Sanuki, Tomoyuki; Kim, Eun-San; Shin, Seung-Hwan; Vogel, Vladimir

    2008-06-01

    We have developed a high-resolution cavity-beam position monitor (BPM) to be used at the focal point of the ATF2, which is a test beam line that is now being built to demonstrate stable orbit control at ˜nanometer resolution. The design of the cavity structure was optimized for the Accelerator Test Facility (ATF) beam in various ways. For example, the cavity has a rectangular shape in order to isolate two dipole modes in orthogonal directions, and a relatively thin gap that is less sensitive to trajectory inclination. A two stage homodyne mixer with highly sensitive electronics and phase-sensitive detection was also developed. Two BPM blocks, each containing two cavity BPMs, were installed in the existing ATF beam line using a rigid support frame. After testing the basic characteristics, we measured the resolution using three BPMs. The system demonstrated 8.7 nm position resolution over a dynamic range of 5μm.

  9. Classification of high resolution satellite images

    OpenAIRE

    Karlsson, Anders

    2003-01-01

    In this thesis the Support Vector Machine (SVM)is applied on classification of high resolution satellite images. Sveral different measures for classification, including texture mesasures, 1st order statistics, and simple contextual information were evaluated. Additionnally, the image was segmented, using an enhanced watershed method, in order to improve the classification accuracy.

  10. High-resolution and high-throughput multichannel Fourier transform spectrometer with two-dimensional interferogram warping compensation

    Science.gov (United States)

    Watanabe, A.; Furukawa, H.

    2018-04-01

    The resolution of multichannel Fourier transform (McFT) spectroscopy is insufficient for many applications despite its extreme advantage of high throughput. We propose an improved configuration to realise both performance using a two-dimensional area sensor. For the spectral resolution, we obtained the interferogram of a larger optical path difference by shifting the area sensor without altering any optical components. The non-linear phase error of the interferometer was successfully corrected using a phase-compensation calculation. Warping compensation was also applied to realise a higher throughput to accumulate the signal between vertical pixels. Our approach significantly improved the resolution and signal-to-noise ratio by factors of 1.7 and 34, respectively. This high-resolution and high-sensitivity McFT spectrometer will be useful for detecting weak light signals such as those in non-invasive diagnosis.

  11. A new method for high-resolution characterization of hydraulic conductivity

    Science.gov (United States)

    Liu, Gaisheng; Butler, J.J.; Bohling, Geoffrey C.; Reboulet, Ed; Knobbe, Steve; Hyndman, D.W.

    2009-01-01

    A new probe has been developed for high-resolution characterization of hydraulic conductivity (K) in shallow unconsolidated formations. The probe was recently applied at the Macrodispersion Experiment (MADE) site in Mississippi where K was rapidly characterized at a resolution as fine as 0.015 m, which has not previously been possible. Eleven profiles were obtained with K varying up to 7 orders of magnitude in individual profiles. Currently, high-resolution (0.015-m) profiling has an upper K limit of 10 m/d; lower-resolution (???0.4-m) mode is used in more permeable zones pending modifications. The probe presents a new means to help address unresolved issues of solute transport in heterogeneous systems. Copyright 2009 by the American Geophysical Union.

  12. Evaluation of a High-Resolution Regional Reanalysis for Europe

    Science.gov (United States)

    Ohlwein, C.; Wahl, S.; Keller, J. D.; Bollmeyer, C.

    2014-12-01

    Reanalyses gain more and more importance as a source of meteorological information for many purposes and applications. Several global reanalyses projects (e.g., ERA, MERRA, CSFR, JMA9) produce and verify these data sets to provide time series as long as possible combined with a high data quality. Due to a spatial resolution down to 50-70km and 3-hourly temporal output, they are not suitable for small scale problems (e.g., regional climate assessment, meso-scale NWP verification, input for subsequent models such as river runoff simulations). The implementation of regional reanalyses based on a limited area model along with a data assimilation scheme is able to generate reanalysis data sets with high spatio-temporal resolution. Within the Hans-Ertel-Centre for Weather Research (HErZ), the climate monitoring branch concentrates efforts on the assessment and analysis of regional climate in Germany and Europe. In joint cooperation with DWD (German Meteorological Service), a high-resolution reanalysis system based on the COSMO model has been developed. The regional reanalysis for Europe matches the domain of the CORDEX EURO-11 specifications, albeit at a higher spatial resolution, i.e., 0.055° (6km) instead of 0.11° (12km) and comprises the assimilation of observational data using the existing nudging scheme of COSMO complemented by a special soil moisture analysis with boundary conditions provided by ERA-Interim data. The reanalysis data set covers 6 years (2007-2012) and is currently extended to 16 years. Extensive evaluation of the reanalysis is performed using independent observations with special emphasis on precipitation and high-impact weather situations indicating a better representation of small scale variability. Further, the evaluation shows an added value of the regional reanalysis with respect to the forcing ERA Interim reanalysis and compared to a pure high-resolution dynamical downscaling approach without data assimilation.

  13. High resolution satellite imagery : from spies to pipeline management

    Energy Technology Data Exchange (ETDEWEB)

    Adam, S. [Canadian Geomatic Solutions Ltd., Calgary, AB (Canada); Farrell, M. [TransCanada Transmission, Calgary, AB (Canada)

    2000-07-01

    The launch of Space Imaging's IKONOS satellite in September 1999 has opened the door for corridor applications. The technology has been successfully implemented by TransCanada PipeLines in mapping over 1500 km of their mainline. IKONOS is the world's first commercial high resolution satellite which collects data at 1-meter black/white and 4-meter multi-spectral. Its use is regulated by the U.S. government. It is the best source of high resolution satellite image data. Other sources include the Indian Space Agency's IRS-1 C/D satellite and the Russian SPIN-2 which provides less reliable coverage. In addition, two more high resolution satellites may be launched this year to provide imagery every day of the year. IKONOS scenes as narrow as 5 km can be purchased. TransCanada conducted a pilot study to determine if high resolution satellite imagery is as effective as ortho-photos for identifying population structures within a buffer of TransCanada's east line right-of-way. The study examined three unique segments where residential, commercial, industrial and public features were compared. It was determined that IKONOS imagery is as good as digital ortho-photos for updating structures from low to very high density areas. The satellite imagery was also logistically easier than ortho-photos to acquire. This will be even more evident when the IKONOS image archives begins to grow. 4 tabs., 3 figs.

  14. High resolution radar satellite imagery analysis for safeguards applications

    Energy Technology Data Exchange (ETDEWEB)

    Minet, Christian; Eineder, Michael [German Aerospace Center, Remote Sensing Technology Institute, Department of SAR Signal Processing, Wessling, (Germany); Rezniczek, Arnold [UBA GmbH, Herzogenrath, (Germany); Niemeyer, Irmgard [Forschungszentrum Juelich, Institue of Energy and Climate Research, IEK-6: Nuclear Waste Management and Reactor Safety, Juelich, (Germany)

    2011-12-15

    For monitoring nuclear sites, the use of Synthetic Aperture Radar (SAR) imagery shows essential promises. Unlike optical remote sensing instruments, radar sensors operate under almost all weather conditions and independently of the sunlight, i.e. time of the day. Such technical specifications are required both for continuous and for ad-hoc, timed surveillance tasks. With Cosmo-Skymed, TerraSARX and Radarsat-2, high-resolution SAR imagery with a spatial resolution up to 1m has recently become available. Our work therefore aims to investigate the potential of high-resolution TerraSAR data for nuclear monitoring. This paper focuses on exploiting amplitude of a single acquisition, assessing amplitude changes and phase differences between two acquisitions, and PS-InSAR processing of an image stack.

  15. Effects of display resolution and size on primary diagnosis of chest images using a high-resolution electronic work station

    International Nuclear Information System (INIS)

    Fuhrman, C.R.; Cooperstein, L.A.; Herron, J.; Good, W.F.; Good, B.; Gur, D.; Maitz, G.; Tabor, E.; Hoy, R.J.

    1987-01-01

    To evaluate the acceptability of electronically displayed planar images, the authors have a high-resolution work station. This system utilizes a high-resolution film digitizer (100-micro resolution) interfaced to a mainframe computer and two high-resolution (2,048 X 2,048) display devices (Azuray). In a clinically simulated multiobserver blind study (19 cases and five observers) a prodetermined series of reading sessions is stored on magnetic disk and is transferred to the displays while the preceding set of images is being reviewed. Images can be linearly processed on the fly into 2,000 X 2,000 full resolution, 1,000 X 1,000 minified display, or 1,000 X 1,000 interpolated for full-size display. Results of the study indicate that radiologists accept but do not like significant minification (more than X2), and they rate 2,000 X 2,000 images as having better diagnostic quality than 1,000 X 1,000 images

  16. High-resolution phylogenetic microbial community profiling

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Esther; Coleman-Derr, Devin; Bowman, Brett; Schwientek, Patrick; Clum, Alicia; Copeland, Alex; Ciobanu, Doina; Cheng, Jan-Fang; Gies, Esther; Hallam, Steve; Tringe, Susannah; Woyke, Tanja

    2014-03-17

    The representation of bacterial and archaeal genome sequences is strongly biased towards cultivated organisms, which belong to merely four phylogenetic groups. Functional information and inter-phylum level relationships are still largely underexplored for candidate phyla, which are often referred to as microbial dark matter. Furthermore, a large portion of the 16S rRNA gene records in the GenBank database are labeled as environmental samples and unclassified, which is in part due to low read accuracy, potential chimeric sequences produced during PCR amplifications and the low resolution of short amplicons. In order to improve the phylogenetic classification of novel species and advance our knowledge of the ecosystem function of uncultivated microorganisms, high-throughput full length 16S rRNA gene sequencing methodologies with reduced biases are needed. We evaluated the performance of PacBio single-molecule real-time (SMRT) sequencing in high-resolution phylogenetic microbial community profiling. For this purpose, we compared PacBio and Illumina metagenomic shotgun and 16S rRNA gene sequencing of a mock community as well as of an environmental sample from Sakinaw Lake, British Columbia. Sakinaw Lake is known to contain a large age of microbial species from candidate phyla. Sequencing results show that community structure based on PacBio shotgun and 16S rRNA gene sequences is highly similar in both the mock and the environmental communities. Resolution power and community representation accuracy from SMRT sequencing data appeared to be independent of GC content of microbial genomes and was higher when compared to Illumina-based metagenome shotgun and 16S rRNA gene (iTag) sequences, e.g. full-length sequencing resolved all 23 OTUs in the mock community, while iTags did not resolve closely related species. SMRT sequencing hence offers various potential benefits when characterizing uncharted microbial communities.

  17. Analysis strategies for high-resolution UHF-fMRI data.

    Science.gov (United States)

    Polimeni, Jonathan R; Renvall, Ville; Zaretskaya, Natalia; Fischl, Bruce

    2018-03-01

    Functional MRI (fMRI) benefits from both increased sensitivity and specificity with increasing magnetic field strength, making it a key application for Ultra-High Field (UHF) MRI scanners. Most UHF-fMRI studies utilize the dramatic increases in sensitivity and specificity to acquire high-resolution data reaching sub-millimeter scales, which enable new classes of experiments to probe the functional organization of the human brain. This review article surveys advanced data analysis strategies developed for high-resolution fMRI at UHF. These include strategies designed to mitigate distortion and artifacts associated with higher fields in ways that attempt to preserve spatial resolution of the fMRI data, as well as recently introduced analysis techniques that are enabled by these extremely high-resolution data. Particular focus is placed on anatomically-informed analyses, including cortical surface-based analysis, which are powerful techniques that can guide each step of the analysis from preprocessing to statistical analysis to interpretation and visualization. New intracortical analysis techniques for laminar and columnar fMRI are also reviewed and discussed. Prospects for single-subject individualized analyses are also presented and discussed. Altogether, there are both specific challenges and opportunities presented by UHF-fMRI, and the use of proper analysis strategies can help these valuable data reach their full potential. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. A High-Resolution Stopwatch for Cents

    Science.gov (United States)

    Gingl, Z.; Kopasz, K.

    2011-01-01

    A very low-cost, easy-to-make stopwatch is presented to support various experiments in mechanics. The high-resolution stopwatch is based on two photodetectors connected directly to the microphone input of a sound card. Dedicated free open-source software has been developed and made available to download. The efficiency is demonstrated by a free…

  19. Ring artifact correction for high-resolution micro CT

    International Nuclear Information System (INIS)

    Kyriakou, Yiannis; Prell, Daniel; Kalender, Willi A

    2009-01-01

    In high-resolution micro CT using flat detectors (FD), imperfect or defect detector elements may cause concentric-ring artifacts due to their continuous over- or underestimation of attenuation values, which often disturb image quality. We here present a dedicated image-based ring artifact correction method for high-resolution micro CT, based on median filtering of the reconstructed image and working on a transformed version of the reconstructed images in polar coordinates. This post-processing method reduced ring artifacts in the reconstructed images and improved image quality for phantom and in in vivo scans. Noise and artifacts were reduced both in transversal and in multi-planar reformations along the longitudinal axis. (note)

  20. Digital approach to high-resolution pulse processing for semiconductor detectors

    International Nuclear Information System (INIS)

    Georgiev, A.; Buchner, A.; Gast, W.; Lieder, R.M.

    1992-01-01

    A new design philosophy for processing signals produced by high resolution, large volume semiconductor detectors is described. These detectors, to be used in the next generation of spectrometer arrays for nuclear research (i.e. EUROBALL, etc.), present a set of problems like resolution degradation due to charge trapping and ballistic defect effects, low resolution at a high count rate, poor long term stability, etc. To solve these problems, a new design approach has been developed, including reconstruction of the event charge, providing a pure triangular residual function, and suppressing low frequency noise. 5 refs., 4 figs

  1. Digital approach to high-resolution pulse processing for semiconductor detectors

    Energy Technology Data Exchange (ETDEWEB)

    Georgiev, A [Sofia Univ. (Bulgaria); Buchner, A [Forschungszentrum Rossendorf (Germany); Gast, W; Lieder, R M [Forschungszentrum Juelich GmbH (Germany). Inst. fuer Kernphysik; Stein, J [Target System Electronic GmbH, Solingen, (Germany)

    1992-08-01

    A new design philosophy for processing signals produced by high resolution, large volume semiconductor detectors is described. These detectors, to be used in the next generation of spectrometer arrays for nuclear research (i.e. EUROBALL, etc.), present a set of problems like resolution degradation due to charge trapping and ballistic defect effects, low resolution at a high count rate, poor long term stability, etc. To solve these problems, a new design approach has been developed, including reconstruction of the event charge, providing a pure triangular residual function, and suppressing low frequency noise. 5 refs., 4 figs.

  2. Enhancing GIS Capabilities for High Resolution Earth Science Grids

    Science.gov (United States)

    Koziol, B. W.; Oehmke, R.; Li, P.; O'Kuinghttons, R.; Theurich, G.; DeLuca, C.

    2017-12-01

    Applications for high performance GIS will continue to increase as Earth system models pursue more realistic representations of Earth system processes. Finer spatial resolution model input and output, unstructured or irregular modeling grids, data assimilation, and regional coordinate systems present novel challenges for GIS frameworks operating in the Earth system modeling domain. This presentation provides an overview of two GIS-driven applications that combine high performance software with big geospatial datasets to produce value-added tools for the modeling and geoscientific community. First, a large-scale interpolation experiment using National Hydrography Dataset (NHD) catchments, a high resolution rectilinear CONUS grid, and the Earth System Modeling Framework's (ESMF) conservative interpolation capability will be described. ESMF is a parallel, high-performance software toolkit that provides capabilities (e.g. interpolation) for building and coupling Earth science applications. ESMF is developed primarily by the NOAA Environmental Software Infrastructure and Interoperability (NESII) group. The purpose of this experiment was to test and demonstrate the utility of high performance scientific software in traditional GIS domains. Special attention will be paid to the nuanced requirements for dealing with high resolution, unstructured grids in scientific data formats. Second, a chunked interpolation application using ESMF and OpenClimateGIS (OCGIS) will demonstrate how spatial subsetting can virtually remove computing resource ceilings for very high spatial resolution interpolation operations. OCGIS is a NESII-developed Python software package designed for the geospatial manipulation of high-dimensional scientific datasets. An overview of the data processing workflow, why a chunked approach is required, and how the application could be adapted to meet operational requirements will be discussed here. In addition, we'll provide a general overview of OCGIS

  3. Computer simulation of high resolution transmission electron micrographs: theory and analysis

    International Nuclear Information System (INIS)

    Kilaas, R.

    1985-03-01

    Computer simulation of electron micrographs is an invaluable aid in their proper interpretation and in defining optimum conditions for obtaining images experimentally. Since modern instruments are capable of atomic resolution, simulation techniques employing high precision are required. This thesis makes contributions to four specific areas of this field. First, the validity of a new method for simulating high resolution electron microscope images has been critically examined. Second, three different methods for computing scattering amplitudes in High Resolution Transmission Electron Microscopy (HRTEM) have been investigated as to their ability to include upper Laue layer (ULL) interaction. Third, a new method for computing scattering amplitudes in high resolution transmission electron microscopy has been examined. Fourth, the effect of a surface layer of amorphous silicon dioxide on images of crystalline silicon has been investigated for a range of crystal thicknesses varying from zero to 2 1/2 times that of the surface layer

  4. The development of high resolution silicon x-ray microcalorimeters

    Science.gov (United States)

    Porter, F. S.; Kelley, R. L.; Kilbourne, C. A.

    2005-12-01

    Recently we have produced x-ray microcalorimeters with resolving powers approaching 2000 at 5.9 keV using a spare XRS microcalorimeter array. We attached 400 um square, 8 um thick HgTe absorbers using a variety of attachment methods to an XRS array and ran the detector array at temperatures between 40 and 60 mK. The best results were for absorbers attached using the standard XRS absorber-pixel thermal isolation scheme utilizing SU8 polymer tubes. In this scenario we achieved a resolution of 3.2 eV FWHM at 5.9 keV. Substituting a silicon spacer for the SU8 tubes also yielded sub-4eV results. In contrast, absorbers attached directly to the thermistor produced significant position dependence and thus degraded resolution. Finally, we tested standard 640um-square XRS detectors at reduced bias power at 50mK and achieved a resolution of 3.7eV, a 50% improvement over the XRS flight instrument. Implanted silicon microcalorimeters are a mature flight-qualified technology that still has a substantial phase space for future development. We will discuss these new high resolution results, the various absorber attachment schemes, planned future improvements, and, finally, their relevance to future high resolution x-ray spectrometers including Constellation-X.

  5. High resolution muon computed tomography at neutrino beam facilities

    International Nuclear Information System (INIS)

    Suerfu, B.; Tully, C.G.

    2016-01-01

    X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pion decay pipe at a neutrino beam facility and what can be achieved for momentum resolution in a muon spectrometer. Such an imaging system can be applied in archaeology, art history, engineering, material identification and whenever there is a need to image inside a transportable object constructed of dense materials

  6. Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes

    International Nuclear Information System (INIS)

    Yang Yongfeng; Dokhale, Purushottam A; Silverman, Robert W; Shah, Kanai S; McClish, Mickel A; Farrell, Richard; Entine, Gerald; Cherry, Simon R

    2006-01-01

    We explore dual-ended read out of LSO arrays with two position sensitive avalanche photodiodes (PSAPDs) as a high resolution, high efficiency depth-encoding detector for PET applications. Flood histograms, energy resolution and depth of interaction (DOI) resolution were measured for unpolished LSO arrays with individual crystal sizes of 1.0, 1.3 and 1.5 mm, and for a polished LSO array with 1.3 mm pixels. The thickness of the crystal arrays was 20 mm. Good flood histograms were obtained for all four arrays, and crystals in all four arrays can be clearly resolved. Although the amplitude of each PSAPD signal decreases as the interaction depth moves further from the PSAPD, the sum of the two PSAPD signals is essentially constant with irradiation depth for all four arrays. The energy resolutions were similar for all four arrays, ranging from 14.7% to 15.4%. A DOI resolution of 3-4 mm (including the width of the irradiation band which is ∼2 mm) was obtained for all the unpolished arrays. The best DOI resolution was achieved with the unpolished 1 mm array (average 3.5 mm). The DOI resolution for the 1.3 mm and 1.5 mm unpolished arrays was 3.7 and 4.0 mm respectively. For the polished array, the DOI resolution was only 16.5 mm. Summing the DOI profiles across all crystals for the 1 mm array only degraded the DOI resolution from 3.5 mm to 3.9 mm, indicating that it may not be necessary to calibrate the DOI response separately for each crystal within an array. The DOI response of individual crystals in the array confirms this finding. These results provide a detailed characterization of the DOI response of these PSAPD-based PET detectors which will be important in the design and calibration of a PET scanner making use of this detector approach

  7. A high resolution x-ray fluorescence spectrometer for near edge absorption studies

    International Nuclear Information System (INIS)

    Stojanoff, V.; Hamalainen, K.; Siddons, D.P.; Hastings, J.B.; Berman, L.E.; Cramer, S.; Smith, G.

    1991-01-01

    A high resolution fluorescence spectrometer using a Johann geometry in a back scattering arrangement was developed. The spectrometer, with a resolution of 0.3 eV at 6.5 keV, combined with an incident beam, with a resolution of 0.7 eV, form the basis of a high resolution instrument for measuring x-ray absorption spectra. The advantages of the instrument are illustrated with the near edge absorption spectrum of dysprosium nitrate. 10 refs., 4 figs

  8. High Frequency High Spectral Resolution Focal Plane Arrays for AtLAST

    Science.gov (United States)

    Baryshev, Andrey

    2018-01-01

    Large collecting area single dish telescope such as ATLAST will be especially effective for medium (R 1000) and high (R 50000) spectral resolution observations. Large focal plane array is a natural solution to increase mapping speed. For medium resolution direct detectors with filter banks (KIDs) and or heterodyne technology can be employed. We will analyze performance limits of comparable KID and SIS focal plane array taking into account quantum limit and high background condition of terrestrial observing site. For large heterodyne focal plane arrays, a high current density AlN junctions open possibility of large instantaneous bandwidth >40%. This and possible multi frequency band FPSs presents a practical challenge for spatial sampling and scanning strategies. We will discuss phase array feeds as a possible solution, including a modular back-end system, which can be shared between KID and SIS based FPA. Finally we will discuss achievable sensitivities and pixel co unts for a high frequency (>500 GHz) FPAs and address main technical challenges: LO distribution, wire counts, bias line multiplexing, and monolithic vs. discrete mixer component integration.

  9. Angular dependence of the nanoDot OSL dosimeter

    International Nuclear Information System (INIS)

    Kerns, James R.; Kry, Stephen F.; Sahoo, Narayan; Followill, David S.; Ibbott, Geoffrey S.

    2011-01-01

    Purpose: Optically stimulated luminescent detectors (OSLDs) are quickly gaining popularity as passive dosimeters, with applications in medicine for linac output calibration verification, brachytherapy source verification, treatment plan quality assurance, and clinical dose measurements. With such wide applications, these dosimeters must be characterized for numerous factors affecting their response. The most abundant commercial OSLD is the InLight/OSL system from Landauer, Inc. The purpose of this study was to examine the angular dependence of the nanoDot dosimeter, which is part of the InLight system. Methods: Relative dosimeter response data were taken at several angles in 6 and 18 MV photon beams, as well as a clinical proton beam. These measurements were done within a phantom at a depth beyond the build-up region. To verify the observed angular dependence, additional measurements were conducted as well as Monte Carlo simulations in MCNPX. Results: When irradiated with the incident photon beams parallel to the plane of the dosimeter, the nanoDot response was 4% lower at 6 MV and 3% lower at 18 MV than the response when irradiated with the incident beam normal to the plane of the dosimeter. Monte Carlo simulations at 6 MV showed similar results to the experimental values. Examination of the results in Monte Carlo suggests the cause as partial volume irradiation. In a clinical proton beam, no angular dependence was found. Conclusions: A nontrivial angular response of this OSLD was observed in photon beams. This factor may need to be accounted for when evaluating doses from photon beams incident from a variety of directions.

  10. A new omni-directional multi-camera system for high resolution surveillance

    Science.gov (United States)

    Cogal, Omer; Akin, Abdulkadir; Seyid, Kerem; Popovic, Vladan; Schmid, Alexandre; Ott, Beat; Wellig, Peter; Leblebici, Yusuf

    2014-05-01

    Omni-directional high resolution surveillance has a wide application range in defense and security fields. Early systems used for this purpose are based on parabolic mirror or fisheye lens where distortion due to the nature of the optical elements cannot be avoided. Moreover, in such systems, the image resolution is limited to a single image sensor's image resolution. Recently, the Panoptic camera approach that mimics the eyes of flying insects using multiple imagers has been presented. This approach features a novel solution for constructing a spherically arranged wide FOV plenoptic imaging system where the omni-directional image quality is limited by low-end sensors. In this paper, an overview of current Panoptic camera designs is provided. New results for a very-high resolution visible spectrum imaging and recording system inspired from the Panoptic approach are presented. The GigaEye-1 system, with 44 single cameras and 22 FPGAs, is capable of recording omni-directional video in a 360°×100° FOV at 9.5 fps with a resolution over (17,700×4,650) pixels (82.3MP). Real-time video capturing capability is also verified at 30 fps for a resolution over (9,000×2,400) pixels (21.6MP). The next generation system with significantly higher resolution and real-time processing capacity, called GigaEye-2, is currently under development. The important capacity of GigaEye-1 opens the door to various post-processing techniques in surveillance domain such as large perimeter object tracking, very-high resolution depth map estimation and high dynamicrange imaging which are beyond standard stitching and panorama generation methods.

  11. EMODnet High Resolution Seabed Mapping - further developing a high resolution digital bathymetry for European seas

    Science.gov (United States)

    Schaap, D.; Schmitt, T.

    2017-12-01

    Access to marine data is a key issue for the EU Marine Strategy Framework Directive and the EU Marine Knowledge 2020 agenda and includes the European Marine Observation and Data Network (EMODnet) initiative. EMODnet aims at assembling European marine data, data products and metadata from diverse sources in a uniform way. The EMODnet Bathymetry project has developed Digital Terrain Models (DTM) for the European seas. These have been produced from survey and aggregated data sets that are indexed with metadata by adopting the SeaDataNet Catalogue services. SeaDataNet is a network of major oceanographic data centres around the European seas that manage, operate and further develop a pan-European infrastructure for marine and ocean data management. The latest EMODnet Bathymetry DTM release has a grid resolution of 1/8 arcminute and covers all European sea regions. Use has been made of circa 7800 gathered survey datasets and composite DTMs. Catalogues and the EMODnet DTM are published at the dedicated EMODnet Bathymetry portal including a versatile DTM viewing and downloading service. End December 2016 the Bathymetry project has been succeeded by EMODnet High Resolution Seabed Mapping (HRSM). This continues gathering of bathymetric in-situ data sets with extra efforts for near coastal waters and coastal zones. In addition Satellite Derived Bathymetry data are included to fill gaps in coverage of the coastal zones. The extra data and composite DTMs will increase the coverage of the European seas and its coastlines, and provide input for producing an EMODnet DTM with a common resolution of 1/16 arc minutes. The Bathymetry Viewing and Download service will be upgraded to provide a multi-resolution map and including 3D viewing. The higher resolution DTMs will also be used to determine best-estimates of the European coastline for a range of tidal levels (HAT, MHW, MSL, Chart Datum, LAT), thereby making use of a tidal model for Europe. Extra challenges will be `moving to the

  12. High resolution microphotonic needle for endoscopic imaging (Conference Presentation)

    Science.gov (United States)

    Tadayon, Mohammad Amin; Mohanty, Aseema; Roberts, Samantha P.; Barbosa, Felippe; Lipson, Michal

    2017-02-01

    GRIN (Graded index) lens have revolutionized micro endoscopy enabling deep tissue imaging with high resolution. The challenges of traditional GRIN lenses are their large size (when compared with the field of view) and their limited resolution. This is because of the relatively weak NA in standard graded index lenses. Here we introduce a novel micro-needle platform for endoscopy with much higher resolution than traditional GRIN lenses and a FOV that corresponds to the whole cross section of the needle. The platform is based on polymeric (SU-8) waveguide integrated with a microlens micro fabricated on a silicon substrate using a unique molding process. Due to the high index of refraction of the material the NA of the needle is much higher than traditional GRIN lenses. We tested the probe in a fluorescent dye solution (19.6 µM Alexa Flour 647 solution) and measured a numerical aperture of 0.25, focal length of about 175 µm and minimal spot size of about 1.6 µm. We show that the platform can image a sample with the field of view corresponding to the cross sectional area of the waveguide (80x100 µm2). The waveguide size can in principle be modified to vary size of the imaging field of view. This demonstration, combined with our previous work demonstrating our ability to implant the high NA needle in a live animal, shows that the proposed system can be used for deep tissue imaging with very high resolution and high field of view.

  13. Imaging collagen type I fibrillogenesis with high spatiotemporal resolution

    International Nuclear Information System (INIS)

    Stamov, Dimitar R; Stock, Erik; Franz, Clemens M; Jähnke, Torsten; Haschke, Heiko

    2015-01-01

    Fibrillar collagens, such as collagen type I, belong to the most abundant extracellular matrix proteins and they have received much attention over the last five decades due to their large interactome, complex hierarchical structure and high mechanical stability. Nevertheless, the collagen self-assembly process is still incompletely understood. Determining the real-time kinetics of collagen type I formation is therefore pivotal for better understanding of collagen type I structure and function, but visualising the dynamic self-assembly process of collagen I on the molecular scale requires imaging techniques offering high spatiotemporal resolution. Fast and high-speed scanning atomic force microscopes (AFM) provide the means to study such processes on the timescale of seconds under near-physiological conditions. In this study we have applied fast AFM tip scanning to study the assembly kinetics of fibrillar collagen type I nanomatrices with a temporal resolution reaching eight seconds for a frame size of 500 nm. By modifying the buffer composition and pH value, the kinetics of collagen fibrillogenesis can be adjusted for optimal analysis by fast AFM scanning. We furthermore show that amplitude-modulation imaging can be successfully applied to extract additional structural information from collagen samples even at high scan rates. Fast AFM scanning with controlled amplitude modulation therefore provides a versatile platform for studying dynamic collagen self-assembly processes at high resolution. - Highlights: • Continuous non-invasive time-lapse investigation of collagen I fibrillogenesis in situ. • Imaging of collagen I self-assembly with high spatiotemporal resolution. • Application of setpoint modulation to study the hierarchical structure of collagen I. • Observing real-time formation of the D-banding pattern in collagen I

  14. Imaging collagen type I fibrillogenesis with high spatiotemporal resolution

    Energy Technology Data Exchange (ETDEWEB)

    Stamov, Dimitar R, E-mail: stamov@jpk.com [JPK Instruments AG, Bouchéstrasse 12, 12435 Berlin (Germany); Stock, Erik [JPK Instruments AG, Bouchéstrasse 12, 12435 Berlin (Germany); Franz, Clemens M [DFG-Center for Functional Nanostructures (CFN), Karlsruhe Institute of Technology (KIT), Wolfgang-Gaede-Strasse 1a, 76131 Karlsruhe (Germany); Jähnke, Torsten; Haschke, Heiko [JPK Instruments AG, Bouchéstrasse 12, 12435 Berlin (Germany)

    2015-02-15

    Fibrillar collagens, such as collagen type I, belong to the most abundant extracellular matrix proteins and they have received much attention over the last five decades due to their large interactome, complex hierarchical structure and high mechanical stability. Nevertheless, the collagen self-assembly process is still incompletely understood. Determining the real-time kinetics of collagen type I formation is therefore pivotal for better understanding of collagen type I structure and function, but visualising the dynamic self-assembly process of collagen I on the molecular scale requires imaging techniques offering high spatiotemporal resolution. Fast and high-speed scanning atomic force microscopes (AFM) provide the means to study such processes on the timescale of seconds under near-physiological conditions. In this study we have applied fast AFM tip scanning to study the assembly kinetics of fibrillar collagen type I nanomatrices with a temporal resolution reaching eight seconds for a frame size of 500 nm. By modifying the buffer composition and pH value, the kinetics of collagen fibrillogenesis can be adjusted for optimal analysis by fast AFM scanning. We furthermore show that amplitude-modulation imaging can be successfully applied to extract additional structural information from collagen samples even at high scan rates. Fast AFM scanning with controlled amplitude modulation therefore provides a versatile platform for studying dynamic collagen self-assembly processes at high resolution. - Highlights: • Continuous non-invasive time-lapse investigation of collagen I fibrillogenesis in situ. • Imaging of collagen I self-assembly with high spatiotemporal resolution. • Application of setpoint modulation to study the hierarchical structure of collagen I. • Observing real-time formation of the D-banding pattern in collagen I.

  15. High-resolution fiber-optic microendoscopy for in situ cellular imaging.

    Science.gov (United States)

    Pierce, Mark; Yu, Dihua; Richards-Kortum, Rebecca

    2011-01-11

    Many biological and clinical studies require the longitudinal study and analysis of morphology and function with cellular level resolution. Traditionally, multiple experiments are run in parallel, with individual samples removed from the study at sequential time points for evaluation by light microscopy. Several intravital techniques have been developed, with confocal, multiphoton, and second harmonic microscopy all demonstrating their ability to be used for imaging in situ. With these systems, however, the required infrastructure is complex and expensive, involving scanning laser systems and complex light sources. Here we present a protocol for the design and assembly of a high-resolution microendoscope which can be built in a day using off-the-shelf components for under US$5,000. The platform offers flexibility in terms of image resolution, field-of-view, and operating wavelength, and we describe how these parameters can be easily modified to meet the specific needs of the end user. We and others have explored the use of the high-resolution microendoscope (HRME) in in vitro cell culture, in excised and living animal tissues, and in human tissues in vivo. Users have reported the use of several different fluorescent contrast agents, including proflavine, benzoporphyrin-derivative monoacid ring A (BPD-MA), and fluoroscein, all of which have received full, or investigational approval from the FDA for use in human subjects. High-resolution microendoscopy, in the form described here, may appeal to a wide range of researchers working in the basic and clinical sciences. The technique offers an effective and economical approach which complements traditional benchtop microscopy, by enabling the user to perform high-resolution, longitudinal imaging in situ.

  16. Compressed sensing cine imaging with high spatial or high temporal resolution for analysis of left ventricular function.

    Science.gov (United States)

    Goebel, Juliane; Nensa, Felix; Schemuth, Haemi P; Maderwald, Stefan; Gratz, Marcel; Quick, Harald H; Schlosser, Thomas; Nassenstein, Kai

    2016-08-01

    To assess two compressed sensing cine magnetic resonance imaging (MRI) sequences with high spatial or high temporal resolution in comparison to a reference steady-state free precession cine (SSFP) sequence for reliable quantification of left ventricular (LV) volumes. LV short axis stacks of two compressed sensing breath-hold cine sequences with high spatial resolution (SPARSE-SENSE HS: temporal resolution: 40 msec, in-plane resolution: 1.0 × 1.0 mm(2) ) and high temporal resolution (SPARSE-SENSE HT: temporal resolution: 11 msec, in-plane resolution: 1.7 × 1.7 mm(2) ) and of a reference cine SSFP sequence (standard SSFP: temporal resolution: 40 msec, in-plane resolution: 1.7 × 1.7 mm(2) ) were acquired in 16 healthy volunteers on a 1.5T MR system. LV parameters were analyzed semiautomatically twice by one reader and once by a second reader. The volumetric agreement between sequences was analyzed using paired t-test, Bland-Altman plots, and Passing-Bablock regression. Small differences were observed between standard SSFP and SPARSE-SENSE HS for stroke volume (SV; -7 ± 11 ml; P = 0.024), ejection fraction (EF; -2 ± 3%; P = 0.019), and myocardial mass (9 ± 9 g; P = 0.001), but not for end-diastolic volume (EDV; P = 0.079) and end-systolic volume (ESV; P = 0.266). No significant differences were observed between standard SSFP and SPARSE-SENSE HT regarding EDV (P = 0.956), SV (P = 0.088), and EF (P = 0.103), but for ESV (3 ± 5 ml; P = 0.039) and myocardial mass (8 ± 10 ml; P = 0.007). Bland-Altman analysis showed good agreement between the sequences (maximum bias ≤ -8%). Two compressed sensing cine sequences, one with high spatial resolution and one with high temporal resolution, showed good agreement with standard SSFP for LV volume assessment. J. Magn. Reson. Imaging 2016;44:366-374. © 2016 Wiley Periodicals, Inc.

  17. 1024 matrix image reconstruction: usefulness in high resolution chest CT

    International Nuclear Information System (INIS)

    Jeong, Sun Young; Chung, Myung Jin; Chong, Se Min; Sung, Yon Mi; Lee, Kyung Soo

    2006-01-01

    We tried to evaluate whether high resolution chest CT with a 1,024 matrix has a significant advantage in image quality compared to a 512 matrix. Each set of 512 and 1024 matrix high resolution chest CT scans with both 0.625 mm and 1.25 mm slice thickness were obtained from 26 patients. Seventy locations that contained twenty-four low density lesions without sharp boundary such as emphysema, and forty-six sharp linear densities such as linear fibrosis were selected; these were randomly displayed on a five mega pixel LCD monitor. All the images were masked for information concerning the matrix size and slice thickness. Two chest radiologists scored the image quality of each ar rowed lesion as follows: (1) undistinguishable, (2) poorly distinguishable, (3) fairly distinguishable, (4) well visible and (5) excellently visible. The scores were compared from the aspects of matrix size, slice thickness and the different observers by using ANOVA tests. The average and standard deviation of image quality were 3.09 (± .92) for the 0.625 mm x 512 matrix, 3.16 (± .84) for the 0.625 mm x 1024 matrix, 2.49 (± 1.02) for the 1.25 mm x 512 matrix, and 2.35 (± 1.02) for the 1.25 mm x 1024 matrix, respectively. The image quality on both matrices of the high resolution chest CT scans with a 0.625 mm slice thickness was significantly better than that on the 1.25 mm slice thickness (ρ < 0.001). However, the image quality on the 1024 matrix high resolution chest CT scans was not significantly different from that on the 512 matrix high resolution chest CT scans (ρ = 0.678). The interobserver variation between the two observers was not significant (ρ = 0.691). We think that 1024 matrix image reconstruction for high resolution chest CT may not be clinical useful

  18. Study on a high resolution positron emission tomography scanner for brain study

    International Nuclear Information System (INIS)

    Nohara, N.; Tomitani, T.; Yamamoto, M.; Murayama, H.; Tanaka, E.

    1990-01-01

    The spatial resolution of positron emission tomography (PET) scanners is usually limited by the finite size of crystals such as bismuth germanate (BGO). To attain high resolution as well as high sensitivity, it is essential to use a large number of small BGO crystals arranged in close-packing on circular rings. In developing high resolution PET scanners, however, there are two physical factors limiting the spatial resolution. One is the finite range of positrons before annihilation and the other the deviation from 180 degrees of annihilation photons. The effect of the factors on the spatial resolution has been evaluated for positron-emitting sources as a function of detector ring radius. A high resolution PET scanner has been developed for brain study, aiming to have spatial resolutions as high as less than 4-mm FWHM in tomographic plane and less than 6-mm FWHM in axial direction at the detector ring center. For the goal of the high resolutions a multi-segment type of photomultiplier tubes has been specially designed and developed, which allows one tube to be directly coupled by four BGO crystals. The scanner consists of five detector rings of 47-cm in diameter, using all 1200 BGO crystals each measuring 5 mm x 12 mm x 30 mm. The scanner provides simultaneous 9 images by combination of in-plane and cross-plane, offering a 24-cm dia. x7.4-cm field-of-view. Physical performance of the scanner was investigated. At the ring center, the spatial resolution in the tomographic plane was measured to be 3.5-mm FWHM. The axial resolution was measured to be 5.7-mm FWHM for in-plane and 5.3-mm FWHM for cross-plane. Sensitivity for a 20-cm dia. uniform source was measured to be 9.5 kcps/μCi/ml for in-plane and 15.3 kcps/μCi/ml for cross-plane. (J.P.N.)

  19. Beam-transport system for high-resolution heavy-ion spectroscopy

    International Nuclear Information System (INIS)

    Roussel, P.; Kashy, E.

    1980-01-01

    A method is given to adjust a beam-transport system to the requirements of high-energy resolution heavy-ion spectroscopy. The results of a test experiment performed on a MP tandem with a 12 C beam are shown. A drastic improvement in energy resolution is obtained for a kinematical factor K=1/p dp/dtheta=0.12 [fr

  20. Workshop on high-resolution, large-acceptance spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Zeidman, B. (ed.)

    1981-01-01

    The purpose of the Workshop on High-Resolution, Large-Acceptance Spectrometers was to provide a means for exchange of information among those actively engaged in the design and construction of these new spectrometers. Thirty-seven papers were prepared for the data base.

  1. Very high-resolution regional climate simulations over Scandinavia-present climate

    DEFF Research Database (Denmark)

    Christensen, Ole B.; Christensen, Jens H.; Machenhauer, Bennert

    1998-01-01

    realistically simulated. It is found in particular that in mountainous regions the high-resolution simulation shows improvements in the simulation of hydrologically relevant fields such as runoff and snow cover. Also, the distribution of precipitation on different intensity classes is most realistically...... on a high-density station network for the Scandinavian countries compiled for the present study. The simulated runoff is compared with observed data from Sweden extracted from a Swedish climatological atlas. These runoff data indicate that the precipitation analyses are underestimating the true...... simulated in the high-resolution simulation. It does, however, inherit certain large-scale systematic errors from the driving GCM. In many cases these errors increase with increasing resolution. Model verification of near-surface temperature and precipitation is made using a new gridded climatology based...

  2. Digital signal processors for cryogenic high-resolution x-ray detector readout

    International Nuclear Information System (INIS)

    Friedrich, Stephan; Drury, Owen B.; Bechstein, Sylke; Hennig, Wolfgang; Momayezi, Michael

    2003-01-01

    We are developing fast digital signal processors (DSPs) to read out superconducting high-resolution X-ray detectors with on-line pulse processing. For superconducting tunnel junction (STJ) detector read-out, the DSPs offer online filtering, rise time discrimination and pile-up rejection. Compared to analog pulse processing, DSP readout somewhat degrades the detector resolution, but improves the spectral purity of the detector response. We discuss DSP performance with our 9-channel STJ array for synchrotron-based high-resolution X-ray spectroscopy. (author)

  3. High spatial resolution CT image reconstruction using parallel computing

    International Nuclear Information System (INIS)

    Yin Yin; Liu Li; Sun Gongxing

    2003-01-01

    Using the PC cluster system with 16 dual CPU nodes, we accelerate the FBP and OR-OSEM reconstruction of high spatial resolution image (2048 x 2048). Based on the number of projections, we rewrite the reconstruction algorithms into parallel format and dispatch the tasks to each CPU. By parallel computing, the speedup factor is roughly equal to the number of CPUs, which can be up to about 25 times when 25 CPUs used. This technique is very suitable for real-time high spatial resolution CT image reconstruction. (authors)

  4. High resolution and simultaneous monitoring of airborne radionuclides

    International Nuclear Information System (INIS)

    Abe, T.; Yamaguchi, Y.; Muguntha Manikandan, N.; Komura, K.

    2005-01-01

    By using 11 extremely low background Ge detectors at Ogoya Underground Laboratory, it became possible to investigate temporal variations of airborne 212 Pb (T 1/2 =10.6 h) along with 210 Pb and 7 Be with order of magnitude higher time resolution. Then, we have measured airborne nuclides at three monitoring points, (1) roof of our laboratory (LLRL; 40 m ASL), (2) Shinshiku Plateau (640 m ASL) located about 8 km from LLRL as a comparison of vertical distribution, and (3) Hegura Island (10 m ASL) at about 50 km from Wajima located north of Noto Peninsula facing on the Sea of Japan (about 180 km to the north-northeast of LLRL), to investigate influence of Asian continent. Airborne nuclides were collected by high volume air samplers at intervals of a few hours at either two or three points simultaneously. In the same manner, high resolution monitoring was carried out also at the time of passage of typhoon and cold front. In this study, we observed drastic temporal variations of airborne radionuclides and correlations of multiple monitoring points. The results indicate that high resolution and simultaneous monitoring is very useful to understand dynamic state of variations of airborne nuclides due to short and long-term air-mass movement. (author)

  5. High-resolution multimodal clinical multiphoton tomography of skin

    Science.gov (United States)

    König, Karsten

    2011-03-01

    This review focuses on multimodal multiphoton tomography based on near infrared femtosecond lasers. Clinical multiphoton tomographs for 3D high-resolution in vivo imaging have been placed into the market several years ago. The second generation of this Prism-Award winning High-Tech skin imaging tool (MPTflex) was introduced in 2010. The same year, the world's first clinical CARS studies have been performed with a hybrid multimodal multiphoton tomograph. In particular, non-fluorescent lipids and water as well as mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen has been imaged with submicron resolution in patients suffering from psoriasis. Further multimodal approaches include the combination of multiphoton tomographs with low-resolution wide-field systems such as ultrasound, optoacoustical, OCT, and dermoscopy systems. Multiphoton tomographs are currently employed in Australia, Japan, the US, and in several European countries for early diagnosis of skin cancer, optimization of treatment strategies, and cosmetic research including long-term testing of sunscreen nanoparticles as well as anti-aging products.

  6. Estimation of identification limit for a small-type OSL dosimeter on the medical images by measurement of X-ray spectra

    OpenAIRE

    Takegami, Kazuki ; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi ; Maehata, Itsumi ; Kanazawa, Yuki ; Okazaki, Tohru ; Hashizume, Takuya ; Kobayashi, Ikuo 

    2016-01-01

    Our aim in this study is to derive an identification limit on a dosimeter for not disturbing a medical image when patients wear a small-type optically stimulated luminescence (OSL) dosimeter on their bodies during X-ray diagnostic imaging. For evaluation of the detection limit based on an analysis of X-ray spectra, we propose a new quantitative identification method. We performed experiments for which we used diagnostic X-ray equipment, a soft-tissue-equivalent phantom (1–20 cm), and a CdTe X...

  7. Integrated High Resolution Monitoring of Mediterranean vegetation

    Science.gov (United States)

    Cesaraccio, Carla; Piga, Alessandra; Ventura, Andrea; Arca, Angelo; Duce, Pierpaolo; Mereu, Simone

    2017-04-01

    The study of the vegetation features in a complex and highly vulnerable ecosystems, such as Mediterranean maquis, leads to the need of using continuous monitoring systems at high spatial and temporal resolution, for a better interpretation of the mechanisms of phenological and eco-physiological processes. Near-surface remote sensing techniques are used to quantify, at high temporal resolution, and with a certain degree of spatial integration, the seasonal variations of the surface optical and radiometric properties. In recent decades, the design and implementation of global monitoring networks involved the use of non-destructive and/or cheaper approaches such as (i) continuous surface fluxes measurement stations, (ii) phenological observation networks, and (iii) measurement of temporal and spatial variations of the vegetation spectral properties. In this work preliminary results from the ECO-SCALE (Integrated High Resolution Monitoring of Mediterranean vegetation) project are reported. The project was manly aimed to develop an integrated system for environmental monitoring based on digital photography, hyperspectral radiometry , and micrometeorological techniques during three years of experimentation (2013-2016) in a Mediterranean site of Italy (Capo Caccia, Alghero). The main results concerned the analysis of chromatic coordinates indices from digital images, to characterized the phenological patterns for typical shrubland species, determining start and duration of the growing season, and the physiological status in relation to different environmental drought conditions; then the seasonal patterns of canopy phenology, was compared to NEE (Net Ecosystem Exchange) patterns, showing similarities. However, maximum values of NEE and ER (Ecosystem respiration), and short term variation, seemed mainly tuned by inter annual pattern of meteorological variables, in particular of temperature recorded in the months preceding the vegetation green-up. Finally, green signals

  8. A multi-channel high-resolution time recorder system

    International Nuclear Information System (INIS)

    Zhang Lingyun; Yang Xiaojun; Song Kezhu; Wang Yanfang

    2004-01-01

    This paper introduces a multi-channel and high-speed time recorder system, which was originally designed to work in the experiments of quantum cryptography research. The novelty of the system is that all the hardware logic is performed by only one FPGA. The system can achieve several desirable features, such as simplicity, high resolution and high processing speed. (authors)

  9. Application of high resolution synchrotron micro-CT radiation in dental implant osseointegration

    DEFF Research Database (Denmark)

    Neldam, Camilla Albeck; Lauridsen, Torsten; Rack, Alexander

    2015-01-01

    The purpose of this study was to describe a refined method using high-resolution synchrotron radiation microtomography (SRmicro-CT) to evaluate osseointegration and peri-implant bone volume fraction after titanium dental implant insertion. SRmicro-CT is considered gold standard evaluating bone...... microarchitecture. Its high resolution, high contrast, and excellent high signal-to-noise-ratio all contribute to the highest spatial resolutions achievable today. Using SRmicro-CT at a voxel size of 5 μm in an experimental goat mandible model, the peri-implant bone volume fraction was found to quickly increase...

  10. An angle encoder for super-high resolution and super-high accuracy using SelfA

    Science.gov (United States)

    Watanabe, Tsukasa; Kon, Masahito; Nabeshima, Nobuo; Taniguchi, Kayoko

    2014-06-01

    Angular measurement technology at high resolution for applications such as in hard disk drive manufacturing machines, precision measurement equipment and aspherical process machines requires a rotary encoder with high accuracy, high resolution and high response speed. However, a rotary encoder has angular deviation factors during operation due to scale error or installation error. It has been assumed to be impossible to achieve accuracy below 0.1″ in angular measurement or control after the installation onto the rotating axis. Self-calibration (Lu and Trumper 2007 CIRP Ann. 56 499; Kim et al 2011 Proc. MacroScale; Probst 2008 Meas. Sci. Technol. 19 015101; Probst et al Meas. Sci. Technol. 9 1059; Tadashi and Makoto 1993 J. Robot. Mechatronics 5 448; Ralf et al 2006 Meas. Sci. Technol. 17 2811) and cross-calibration (Probst et al 1998 Meas. Sci. Technol. 9 1059; Just et al 2009 Precis. Eng. 33 530; Burnashev 2013 Quantum Electron. 43 130) technologies for a rotary encoder have been actively discussed on the basis of the principle of circular closure. This discussion prompted the development of rotary tables which achieve reliable and high accuracy angular verification. We apply these technologies for the development of a rotary encoder not only to meet the requirement of super-high accuracy but also to meet that of super-high resolution. This paper presents the development of an encoder with 221 = 2097 152 resolutions per rotation (360°), that is, corresponding to a 0.62″ signal period, achieved by the combination of a laser rotary encoder supplied by Magnescale Co., Ltd and a self-calibratable encoder (SelfA) supplied by The National Institute of Advanced Industrial Science & Technology (AIST). In addition, this paper introduces the development of a rotary encoder to guarantee ±0.03″ accuracy at any point of the interpolated signal, with respect to the encoder at the minimum resolution of 233, that is, corresponding to a 0.0015″ signal period after

  11. Quantifying and containing the curse of high resolution coronal imaging

    Directory of Open Access Journals (Sweden)

    V. Delouille

    2008-10-01

    Full Text Available Future missions such as Solar Orbiter (SO, InterHelioprobe, or Solar Probe aim at approaching the Sun closer than ever before, with on board some high resolution imagers (HRI having a subsecond cadence and a pixel area of about (80 km2 at the Sun during perihelion. In order to guarantee their scientific success, it is necessary to evaluate if the photon counts available at these resolution and cadence will provide a sufficient signal-to-noise ratio (SNR. For example, if the inhomogeneities in the Quiet Sun emission prevail at higher resolution, one may hope to locally have more photon counts than in the case of a uniform source. It is relevant to quantify how inhomogeneous the quiet corona will be for a pixel pitch that is about 20 times smaller than in the case of SoHO/EIT, and 5 times smaller than TRACE. We perform a first step in this direction by analyzing and characterizing the spatial intermittency of Quiet Sun images thanks to a multifractal analysis. We identify the parameters that specify the scale-invariance behavior. This identification allows next to select a family of multifractal processes, namely the Compound Poisson Cascades, that can synthesize artificial images having some of the scale-invariance properties observed on the recorded images. The prevalence of self-similarity in Quiet Sun coronal images makes it relevant to study the ratio between the SNR present at SoHO/EIT images and in coarsened images. SoHO/EIT images thus play the role of "high resolution" images, whereas the "low-resolution" coarsened images are rebinned so as to simulate a smaller angular resolution and/or a larger distance to the Sun. For a fixed difference in angular resolution and in Spacecraft-Sun distance, we determine the proportion of pixels having a SNR preserved at high resolution given a particular increase in effective area. If scale-invariance continues to prevail at smaller scales, the conclusion reached with SoHO/EIT images can be transposed

  12. A High-resolution Reanalysis for the European CORDEX Region

    Science.gov (United States)

    Bentzien, Sabrina; Bollmeyer, Christoph; Crewell, Susanne; Friederichs, Petra; Hense, Andreas; Keller, Jan; Keune, Jessica; Kneifel, Stefan; Ohlwein, Christian; Pscheidt, Ieda; Redl, Stephanie; Steinke, Sandra

    2014-05-01

    A High-resolution Reanalysis for the European CORDEX Region Within the Hans-Ertel-Centre for Weather Research (HErZ), the climate monitoring branch concentrates efforts on the assessment and analysis of regional climate in Germany and Europe. In joint cooperation with DWD (German Meteorological Service), a high-resolution reanalysis system based on the COSMO model has been developed. Reanalyses gain more and more importance as a source of meteorological information for many purposes and applications. Several global reanalyses projects (e.g., ERA, MERRA, CSFR, JMA9) produce and verify these data sets to provide time series as long as possible combined with a high data quality. Due to a spatial resolution down to 50-70km and 3-hourly temporal output, they are not suitable for small scale problems (e.g., regional climate assessment, meso-scale NWP verification, input for subsequent models such as river runoff simulations). The implementation of regional reanalyses based on a limited area model along with a data assimilation scheme is able to generate reanalysis data sets with high spatio-temporal resolution. The work presented here focuses on the regional reanalysis for Europe with a domain matching the CORDEX-EURO-11 specifications, albeit at a higher spatial resolution, i.e., 0.055° (6km) instead of 0.11° (12km). The COSMO reanalysis system comprises the assimilation of observational data using the existing nudging scheme of COSMO and is complemented by a special soil moisture analysis and boundary conditions given by ERA-interim data. The reanalysis data set currently covers 6 years (2007-2012). The evaluation of the reanalyses is done using independent observations with special emphasis on precipitation and high-impact weather situations. The development and evaluation of the COSMO-based reanalysis for the CORDEX-Euro domain can be seen as a preparation for joint European activities on the development of an ensemble system of regional reanalyses for Europe.

  13. High Time Resolution Astrophysics

    CERN Document Server

    Phelan, Don; Shearer, Andrew

    2008-01-01

    High Time Resolution Astrophysics (HTRA) is an important new window to the universe and a vital tool in understanding a range of phenomena from diverse objects and radiative processes. This importance is demonstrated in this volume with the description of a number of topics in astrophysics, including quantum optics, cataclysmic variables, pulsars, X-ray binaries and stellar pulsations to name a few. Underlining this science foundation, technological developments in both instrumentation and detectors are described. These instruments and detectors combined cover a wide range of timescales and can measure fluxes, spectra and polarisation. These advances make it possible for HTRA to make a big contribution to our understanding of the Universe in the next decade.

  14. High resolution ultrasonic densitometer

    International Nuclear Information System (INIS)

    Dress, W.B.

    1983-01-01

    The velocity of torsional stress pulses in an ultrasonic waveguide of non-circular cross section is affected by the temperature and density of the surrounding medium. Measurement of the transit times of acoustic echoes from the ends of a sensor section are interpreted as level, density, and temperature of the fluid environment surrounding that section. This paper examines methods of making these measurements to obtain high resolution, temperature-corrected absolute and relative density and level determinations of the fluid. Possible applications include on-line process monitoring, a hand-held density probe for battery charge state indication, and precise inventory control for such diverse fluids as uranium salt solutions in accountability storage and gasoline in service station storage tanks

  15. Simulation study for high resolution alpha particle spectrometry with mesh type collimator

    International Nuclear Information System (INIS)

    Park, Seunghoon; Kwak, Sungwoo; Kang, Hanbyeol; Shin, Jungki; Park, Iljin

    2014-01-01

    An alpha particle spectrometry with a mesh type collimator plays a crucial role in identifying specific radionuclide in a radioactive source collected from the atmosphere or environment. The energy resolution is degraded without collimation because particles with a high angle have a longer path to travel in the air. Therefore, collision with the background increases. The collimator can cut out particles which traveling at a high angle. As a result, an energy distribution with high resolution can be obtained. Therefore, the mesh type collimator is simulated for high resolution alpha particle spectrometry. In conclusion, the collimator can improve resolution. With collimator, the collimator is a role of cutting out particles with a high angle, so, low energy tail and broadened energy distribution can be reduced. The mesh diameter is found out as an important factor to control resolution and counting efficiency. Therefore, a target particle, for example, 235 U, can be distinguished by a detector with a collimator under a mixture of various nuclides, for example: 232 U, 238 U, and 232 Th

  16. Low-resolution ship detection from high-altitude aerial images

    Science.gov (United States)

    Qi, Shengxiang; Wu, Jianmin; Zhou, Qing; Kang, Minyang

    2018-02-01

    Ship detection from optical images taken by high-altitude aircrafts such as unmanned long-endurance airships and unmanned aerial vehicles has broad applications in marine fishery management, ship monitoring and vessel salvage. However, the major challenge is the limited capability of information processing on unmanned high-altitude platforms. Furthermore, in order to guarantee the wide detection range, unmanned aircrafts generally cruise at high altitudes, resulting in imagery with low-resolution targets and strong clutters suffered by heavy clouds. In this paper, we propose a low-resolution ship detection method to extract ships from these high-altitude optical images. Inspired by a recent research on visual saliency detection indicating that small salient signals could be well detected by a gradient enhancement operation combined with Gaussian smoothing, we propose the facet kernel filtering to rapidly suppress cluttered backgrounds and delineate candidate target regions from the sea surface. Then, the principal component analysis (PCA) is used to compute the orientation of the target axis, followed by a simplified histogram of oriented gradient (HOG) descriptor to characterize the ship shape property. Finally, support vector machine (SVM) is applied to discriminate real targets and false alarms. Experimental results show that the proposed method actually has high efficiency in low-resolution ship detection.

  17. Gas scintillation glass GEM detector for high-resolution X-ray imaging and CT

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, T., E-mail: fujiwara-t@aist.go.jp [Research Institute for Measurement and Analytical Instrumentation, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8568 (Japan); Mitsuya, Y. [Nuclear Professional School, The University of Tokyo, Tokai, Naka, Ibaraki 319-1188 (Japan); Fushie, T. [Radiment Lab. Inc., Setagaya, Tokyo 156-0044 (Japan); Murata, K.; Kawamura, A.; Koishikawa, A. [XIT Co., Naruse, Machida, Tokyo 194-0045 (Japan); Toyokawa, H. [Research Institute for Measurement and Analytical Instrumentation, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8568 (Japan); Takahashi, H. [Institute of Engineering Innovation, School of Engineering, The University of Tokyo, Bunkyo, Tokyo 113-8654 (Japan)

    2017-04-01

    A high-spatial-resolution X-ray-imaging gaseous detector has been developed with a single high-gas-gain glass gas electron multiplier (G-GEM), scintillation gas, and optical camera. High-resolution X-ray imaging of soft elements is performed with a spatial resolution of 281 µm rms and an effective area of 100×100 mm. In addition, high-resolution X-ray 3D computed tomography (CT) is successfully demonstrated with the gaseous detector. It shows high sensitivity to low-energy X-rays, which results in high-contrast radiographs of objects containing elements with low atomic numbers. In addition, the high yield of scintillation light enables fast X-ray imaging, which is an advantage for constructing CT images with low-energy X-rays.

  18. Novel techniques in VUV high-resolution spectroscopy

    NARCIS (Netherlands)

    Ubachs, W.M.G.; Salumbides, E.J.; Eikema, K.S.E.; de Oliveira, N.; Nahon, L.

    2014-01-01

    Novel VUV sources and techniques for VUV spectroscopy are reviewed. Laser-based VUV sources have been developed via non-linear upconversion of laser pulses in the nanosecond (ns), the picosecond (ps), and femtosecond (fs) domain, and are applied in high-resolution gas phase spectroscopic studies.

  19. Duchenne muscular dystrophy: High-resolution melting curve ...

    African Journals Online (AJOL)

    Duchenne muscular dystrophy: High-resolution melting curve analysis as an affordable diagnostic mutation scanning tool in a South African cohort. ... Genetic screening for D/BMD in South Africa currently includes multiple ligase-dependent probe amplification (MLPA) for exonic deletions and duplications and linkage ...

  20. High-Resolution 3 T MR Microscopy Imaging of Arterial Walls

    International Nuclear Information System (INIS)

    Sailer, Johannes; Rand, Thomas; Berg, Andreas; Sulzbacher, Irene; Peloschek, P.; Hoelzenbein, Thomas; Lammer, Johannes

    2006-01-01

    Purpose. To achieve a high spatial resolution in MR imaging that allows for clear visualization of anatomy and even histology and documentation of plaque morphology in in vitro samples from patients with advanced atherosclerosis. A further objective of our study was to evaluate whether T2-weighted high-resolution MR imaging can provide accurate classification of atherosclerotic plaque according to a modified American Heart Association classification. Methods. T2-weighted images of arteries were obtained in 13 in vitro specimens using a 3 T MR unit (Medspec 300 Avance/Bruker, Ettlingen, Germany) combined with a dedicated MR microscopy system. Measurement parameters were: T2-weighted sequences with TR 3.5 sec, TE 15-120 msec; field of view (FOV) 1.4 x 1.4; NEX 8; matrix 192; and slice thickness 600 μm. MR measurements were compared with corresponding histologic sections. Results. We achieved excellent spatial and contrast resolution in all specimens. We found high agreement between MR images and histology with regard to the morphology and extent of intimal proliferations in all but 2 specimens. We could differentiate fibrous caps and calcifications from lipid plaque components based on differences in signal intensity in order to differentiate hard and soft atheromatous plaques. Hard plaques with predominantly intimal calcifications were found in 7 specimens, and soft plaques with a cholesterol/lipid content in 5 cases. In all specimens, hemorrhage or thrombus formation, and fibrotic and hyalinized tissue could be detected on both MR imaging and histopathology. Conclusion. High-resolution, high-field MR imaging of arterial walls demonstrates the morphologic features, volume, and extent of intimal proliferations with high spatial and contrast resolution in in vitro specimens and can differentiate hard and soft plaques

  1. Motivation for an SSC detector with ultra-high resolution photon detection

    International Nuclear Information System (INIS)

    Gunion, J.F.; Kane, G.

    1992-01-01

    It is well known that incorporating ultra-high resolution photon detection into a general purpose detector for the SSC will be extremely difficult. The authors will argue that the physics signals that could be missed without such resolution are of such importance that a special purpose detector designed specifically for photon final state modes should be constructed, if sufficient resolution cannot be achieved with general purpose detectors. The potentially great value of these signals as a probe of extremely high mass scales is stressed

  2. Comparison of Two Grid Refinement Approaches for High Resolution Regional Climate Modeling: MPAS vs WRF

    Science.gov (United States)

    Leung, L.; Hagos, S. M.; Rauscher, S.; Ringler, T.

    2012-12-01

    This study compares two grid refinement approaches using global variable resolution model and nesting for high-resolution regional climate modeling. The global variable resolution model, Model for Prediction Across Scales (MPAS), and the limited area model, Weather Research and Forecasting (WRF) model, are compared in an idealized aqua-planet context with a focus on the spatial and temporal characteristics of tropical precipitation simulated by the models using the same physics package from the Community Atmosphere Model (CAM4). For MPAS, simulations have been performed with a quasi-uniform resolution global domain at coarse (1 degree) and high (0.25 degree) resolution, and a variable resolution domain with a high-resolution region at 0.25 degree configured inside a coarse resolution global domain at 1 degree resolution. Similarly, WRF has been configured to run on a coarse (1 degree) and high (0.25 degree) resolution tropical channel domain as well as a nested domain with a high-resolution region at 0.25 degree nested two-way inside the coarse resolution (1 degree) tropical channel. The variable resolution or nested simulations are compared against the high-resolution simulations that serve as virtual reality. Both MPAS and WRF simulate 20-day Kelvin waves propagating through the high-resolution domains fairly unaffected by the change in resolution. In addition, both models respond to increased resolution with enhanced precipitation. Grid refinement induces zonal asymmetry in precipitation (heating), accompanied by zonal anomalous Walker like circulations and standing Rossby wave signals. However, there are important differences between the anomalous patterns in MPAS and WRF due to differences in the grid refinement approaches and sensitivity of model physics to grid resolution. This study highlights the need for "scale aware" parameterizations in variable resolution and nested regional models.

  3. Toward high-resolution NMR spectroscopy of microscopic liquid samples

    Energy Technology Data Exchange (ETDEWEB)

    Butler, Mark C.; Mehta, Hardeep S.; Chen, Ying; Reardon, Patrick N.; Renslow, Ryan S.; Khbeis, Michael; Irish, Duane; Mueller, Karl T.

    2017-01-01

    A longstanding limitation of high-resolution NMR spectroscopy is the requirement for samples to have macroscopic dimensions. Commercial probes, for example, are designed for volumes of at least 5 mL, in spite of decades of work directed toward the goal of miniaturization. Progress in miniaturizing inductive detectors has been limited by a perceived need to meet two technical requirements: (1) minimal separation between the sample and the detector, which is essential for sensitivity, and (2) near-perfect magnetic-field homogeneity at the sample, which is typically needed for spectral resolution. The first of these requirements is real, but the second can be relaxed, as we demonstrate here. By using pulse sequences that yield high-resolution spectra in an inhomogeneous field, we eliminate the need for near-perfect field homogeneity and the accompanying requirement for susceptibility matching of microfabricated detector components. With this requirement removed, typical imperfections in microfabricated components can be tolerated, and detector dimensions can be matched to those of the sample, even for samples of volume << 5 uL. Pulse sequences that are robust to field inhomogeneity thus enable small-volume detection with optimal sensitivity. We illustrate the potential of this approach to miniaturization by presenting spectra acquired with a flat-wire detector that can easily be scaled to subnanoliter volumes. In particular, we report high-resolution NMR spectroscopy of an alanine sample of volume 500 pL.

  4. Gamma-Ray Imager With High Spatial And Spectral Resolution

    Science.gov (United States)

    Callas, John L.; Varnell, Larry S.; Wheaton, William A.; Mahoney, William A.

    1996-01-01

    Gamma-ray instrument developed to enable both two-dimensional imaging at relatively high spatial resolution and spectroscopy at fractional-photon-energy resolution of about 10 to the negative 3rd power in photon-energy range from 10 keV to greater than 10 MeV. In its spectroscopic aspect, instrument enables identification of both narrow and weak gamma-ray spectral peaks.

  5. Fuzzy Classification of High Resolution Remote Sensing Scenes Using Visual Attention Features

    Directory of Open Access Journals (Sweden)

    Linyi Li

    2017-01-01

    Full Text Available In recent years the spatial resolutions of remote sensing images have been improved greatly. However, a higher spatial resolution image does not always lead to a better result of automatic scene classification. Visual attention is an important characteristic of the human visual system, which can effectively help to classify remote sensing scenes. In this study, a novel visual attention feature extraction algorithm was proposed, which extracted visual attention features through a multiscale process. And a fuzzy classification method using visual attention features (FC-VAF was developed to perform high resolution remote sensing scene classification. FC-VAF was evaluated by using remote sensing scenes from widely used high resolution remote sensing images, including IKONOS, QuickBird, and ZY-3 images. FC-VAF achieved more accurate classification results than the others according to the quantitative accuracy evaluation indices. We also discussed the role and impacts of different decomposition levels and different wavelets on the classification accuracy. FC-VAF improves the accuracy of high resolution scene classification and therefore advances the research of digital image analysis and the applications of high resolution remote sensing images.

  6. Variational data assimilation system with nesting model for high resolution ocean circulation

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, Yoichi; Igarashi, Hiromichi; Hiyoshi, Yoshimasa; Sasaki, Yuji; Wakamatsu, Tsuyoshi; Awaji, Toshiyuki [Center for Earth Information Science and Technology, Japan Agency for Marine-Earth Science and Technology, 3173-25 Showa-machi, Kanazawa-Ku, Yokohama 236-0001 (Japan); In, Teiji [Japan Marine Science Foundation, 4-24, Minato-cho, Mutsu, Aomori, 035-0064 (Japan); Nakada, Satoshi [Graduate School of Maritime Science, Kobe University, 5-1-1, Fukae-minamimachi, Higashinada-Ku, Kobe, 658-0022 (Japan); Nishina, Kei, E-mail: ishikaway@jamstec.go.jp [Graduate School of Science, Kyoto University, Kitashirakawaoiwake-cho, Sakyo-Ku, Kyoto, 606-8502 (Japan)

    2015-10-15

    To obtain the high-resolution analysis fields for ocean circulation, a new incremental approach is developed using a four-dimensional variational data assimilation system with nesting models. The results show that there are substantial biases when using a classical method combined with data assimilation and downscaling, caused by different dynamics resulting from the different resolutions of the models used within the nesting models. However, a remarkable reduction in biases of the low-resolution model relative to the high-resolution model was observed using our new approach in narrow strait regions, such as the Tsushima and Tsugaru straits, where the difference in the dynamics represented by the high- and low-resolution models is substantial. In addition, error reductions are demonstrated in the downstream region of these narrow channels associated with the propagation of information through the model dynamics. (paper)

  7. Real-time database for high resolution neutron monitor measurements

    Energy Technology Data Exchange (ETDEWEB)

    Steigies, Christian T.; Rother, Oliver M.; Wimmer-Schweingruber, Robert F.; Heber, Bernd [IEAP, Christian-Albrechts-Universitaet zu Kiel (Germany)

    2008-07-01

    The worldwide network of standardised neutron monitors is, after 50 years, still the state-of-the-art instrumentation to measure spectral variations of the primary cosmic ray component. These measurements are an ideal complement to space based cosmic ray measurements. Data from the approximately 50 IGY and NM64 neutron monitors is stored locally but also available through data collections sites like the World Data Center (WDC) or the IZMIRAN ftp server. The data from the WDC is in a standard format, but only hourly values are available. IZMIRAN collects the data in the best available time resolution, but the data arrives on the ftp server only hours, sometimes days, after the measurements. Also, the high time-resolution measurements of the different stations do not have a common format, a conversion routine for each station is needed before they can be used for scientific analysis. Supported by the 7th framework program of the European Commission, we are setting up a real-time database where high resolution cosmic ray measurements will be stored and accessible immediately after the measurement. Stations that do not have 1-minute resolution measurements will be upgraded to 1-minute or better resolution with an affordable standard registration system, that will submit the measurements to the database via the internet in real-time.

  8. High resolution imaging of boron carbide microstructures

    International Nuclear Information System (INIS)

    MacKinnon, I.D.R.; Aselage, T.; Van Deusen, S.B.

    1986-01-01

    Two samples of boron carbide have been examined using high resolution transmission electron microscopy (HRTEM). A hot-pressed B 13 C 2 sample shows a high density of variable width twins normal to (10*1). Subtle shifts or offsets of lattice fringes along the twin plane and normal to approx.(10*5) were also observed. A B 4 C powder showed little evidence of stacking disorder in crystalline regions

  9. A subspace approach to high-resolution spectroscopic imaging.

    Science.gov (United States)

    Lam, Fan; Liang, Zhi-Pei

    2014-04-01

    To accelerate spectroscopic imaging using sparse sampling of (k,t)-space and subspace (or low-rank) modeling to enable high-resolution metabolic imaging with good signal-to-noise ratio. The proposed method, called SPectroscopic Imaging by exploiting spatiospectral CorrElation, exploits a unique property known as partial separability of spectroscopic signals. This property indicates that high-dimensional spectroscopic signals reside in a very low-dimensional subspace and enables special data acquisition and image reconstruction strategies to be used to obtain high-resolution spatiospectral distributions with good signal-to-noise ratio. More specifically, a hybrid chemical shift imaging/echo-planar spectroscopic imaging pulse sequence is proposed for sparse sampling of (k,t)-space, and a low-rank model-based algorithm is proposed for subspace estimation and image reconstruction from sparse data with the capability to incorporate prior information and field inhomogeneity correction. The performance of the proposed method has been evaluated using both computer simulations and phantom studies, which produced very encouraging results. For two-dimensional spectroscopic imaging experiments on a metabolite phantom, a factor of 10 acceleration was achieved with a minimal loss in signal-to-noise ratio compared to the long chemical shift imaging experiments and with a significant gain in signal-to-noise ratio compared to the accelerated echo-planar spectroscopic imaging experiments. The proposed method, SPectroscopic Imaging by exploiting spatiospectral CorrElation, is able to significantly accelerate spectroscopic imaging experiments, making high-resolution metabolic imaging possible. Copyright © 2014 Wiley Periodicals, Inc.

  10. Intracavitary in vivo dosimetry based on multichannel fiber-coupled optically stimulated luminescence (OSL) of Al2O3:C for Curietherapy

    International Nuclear Information System (INIS)

    Spasic, Estelle

    2012-01-01

    The brachytherapy is an old technique using sealed radioactive sources of low or average energy. This technique is still therapeutically and economically relevant today and always evolving (e.g. High Dose Rate (HDR) brachytherapy). This treatment enables to deliver a high dose of irradiation in a limited tumoral volume and enables to minimize the risk of radiation-induced cancer as preserving the Organs at Risks (OAR). However, this technique generates high dose gradients, which makes in vivo dosimetry difficult to implement. Hence, the deviations observed between doses delivered and prescribed are often up to the maximal deviation tolerated by the nuclear safety regulations (± 5%) in conformational radiotherapy. Those regulations have been made mandatory in France since 2011. This thesis has been done within the framework of the ANR-TECSAN INTRADOSE project and is based on the past technological benefits demonstrated during the MAESTRO European project and the ANR-TECSAN CODOFER project, in particular a RL/OSL multichannel instrumentation (Radioluminescence - Optically Stimulated Luminescence) made and validated in preclinical evaluation during the MAESTRO project. The purpose of the INTRADOSE project is to demonstrate the feasibility of the intracavitary In Vivo Dosimetry (IVD) by dosimetric catheter using optical fibers and alumina crystals Al 2 O 3 :C with the aim of improving the safety of patients treated by HDR brachytherapy. This new probe enables to measure a dose distribution (several points) close to the OAR, it offers a little diameter (≤ 3 mm) designed for an intracavitary use (e.g. to insert in the urethra), it is transparent, radiation stable and reusable after dose reading and sterilization. During this study, we have first developed this new dosimetric sensor based on the OSL using the properties of the alumina crystal. Several tests have been done in order to evaluate the feasibility and the compatibility with a medical application. Then

  11. High-resolution spectroscopic probes of collisions and half-collisions

    Energy Technology Data Exchange (ETDEWEB)

    Hall, G.E. [Brookhaven National Laboratory, Upton, NY (United States)

    1993-12-01

    Research in this program explores the dynamics of gas phase collisions and photodissociation by high-resolution laser spectroscopy. Simultaneous state and velocity detection frequently permits a determination of scalar or vector correlations among products. The correlated product distributions are always more informative, and often easier to interpret than the uncorrelated product state distributions. The authors have recently built an apparatus to record transient absorption spectra with 50 nS time resolution and 20 MHz frequency resolution using a single frequency Ti:sapphire laser. The photodissociation of NCCN and C{sub 2}H{sub 5}SCN at 193 nm is discussed.

  12. The demonstration of the auditory ossicles by high resolution CT

    International Nuclear Information System (INIS)

    Lloyd, G.A.S.; Boulay, G.H. du; Phelps, P.D.; Pullicino, P.

    1979-01-01

    The high resolution CT scanning system introduced by EMI in 1978 has added a new dimension to computerised tomography in otology. The apparatus used for this study was an EMI CT 5005 body scanner adapted for head and neck scanning and incorporating a high resolution facility. The latter has proved most advantageous in areas of relatively high differential absorption, so that its application to the demonstration of abnormalities in the petrous temporal bone, and in particular middle ear disease, has been very rewarding. Traumatic ossicular disruptions may now be demonstrated and the high contrast of CT often shows them better than conventional hypocycloidal tomography. The stapes is also better visualised and congenital abnormalities of its superstructure have been recorded. These studies have been achieved with a very acceptable level of radiation to the eye, lens and cornea and the technique is clearly a rival to conventional pluridirectional tomography in the assessment of the petrous temporal bone. With further design improvements high resolution CT could completely replace existing techniques. (orig.) [de

  13. A low-cost personal dosemeter based on optically stimulated luminescence (OSL) of common household salt (NaCl)

    International Nuclear Information System (INIS)

    Ekendahl, Daniela; Bulánek, Boris; Judas, Libor

    2016-01-01

    Salt represents a radiation sensitive material that can be used for dosimetry. The objective of this experimental study was to test a low-cost salt dosemeter that was designed for personnel that are not radiation workers, but can operate in low probability events resulting in a serious external radiation exposure. The dosemeter is based on use of optically stimulated luminescence (OSL) of a common household salt. Attention was concentrated on its energy and angular responses. The dosemeter was fixed to the ICRU slab phantom and irradiated by photons of reference radiation qualities (ISO 4037-1) with mean energies between 33 and 1250 keV. Angular response was investigated for angles of incidence from 0° to 80° for radiation qualities of N-150 (∼118 keV) and S-Cs (∼662 keV). Single-Aliquot Regenerative-dose analytical protocol was employed for dose reconstruction. The results were evaluated with respect to H_p(10) measurement. The salt dosemeter can provide reliable or reasonably conservative H_p(10) estimates in radiation fields where photon energies > 100 keV predominate, radiation incidence angles are from 0° to 80° and also for rotational geometry. Furthermore, a personal dose reconstruction trial was demonstrated. Relative deviation between the measured and reference H_p(10) values was 5.5%. A practical disadvantage of the method is the more demanding analytical protocol. - Highlights: • Common salt has a considerable potential for dosimetry based on use of OSL. • A simple salt personal dosemeter was designed and tested. • Photon energy and angular responses were satisfactory for purposes of accidental dosimetry. • Dose reconstruction trial proved the potential for reliable estimate of personal doses.

  14. High resolution NMR theory and chemical applications

    CERN Document Server

    Becker, Edwin D

    2012-01-01

    High Resolution NMR: Theory and Chemical Applications discusses the principles and theory of nuclear magnetic resonance and how this concept is used in the chemical sciences. This book is written at an intermediate level, with mathematics used to augment verbal descriptions of the phenomena. This text pays attention to developing and interrelating four approaches - the steady state energy levels, the rotating vector picture, the density matrix, and the product operator formalism. The style of this book is based on the assumption that the reader has an acquaintance with the general principles of quantum mechanics, but no extensive background in quantum theory or proficiency in mathematics is required. This book begins with a description of the basic physics, together with a brief account of the historical development of the field. It looks at the study of NMR in liquids, including high resolution NMR in the solid state and the principles of NMR imaging and localized spectroscopy. This book is intended to assis...

  15. Principles of high resolution NMR in solids

    CERN Document Server

    Mehring, Michael

    1983-01-01

    The field of Nuclear Magnetic Resonance (NMR) has developed at a fascinating pace during the last decade. It always has been an extremely valuable tool to the organic chemist by supplying molecular "finger print" spectra at the atomic level. Unfortunately the high resolution achievable in liquid solutions could not be obtained in solids and physicists and physical chemists had to live with unresolved lines open to a wealth of curve fitting procedures and a vast amount of speculations. High resolution NMR in solids seemed to be a paradoxon. Broad structure­ less lines are usually encountered when dealing with NMR in solids. Only with the recent advent of mUltiple pulse, magic angle, cross-polarization, two-dimen­ sional and multiple-quantum spectroscopy and other techniques during the last decade it became possible to resolve finer details of nuclear spin interactions in solids. I have felt that graduate students, researchers and others beginning to get involved with these techniques needed a book which trea...

  16. High resolution NMR theory and chemical applications

    CERN Document Server

    Becker, Edwin D

    1999-01-01

    High Resolution NMR provides a broad treatment of the principles and theory of nuclear magnetic resonance (NMR) as it is used in the chemical sciences. It is written at an "intermediate" level, with mathematics used to augment, rather than replace, clear verbal descriptions of the phenomena. The book is intended to allow a graduate student, advanced undergraduate, or researcher to understand NMR at a fundamental level, and to see illustrations of the applications of NMR to the determination of the structure of small organic molecules and macromolecules, including proteins. Emphasis is on the study of NMR in liquids, but the treatment also includes high resolution NMR in the solid state and the principles of NMR imaging and localized spectroscopy. Careful attention is given to developing and interrelating four approaches - steady state energy levels, the rotating vector picture, the density matrix, and the product operator formalism. The presentation is based on the assumption that the reader has an acquaintan...

  17. High resolution study of high mass pairs and high transverse momentum particles

    International Nuclear Information System (INIS)

    Smith, S.R.

    1983-01-01

    Preliminary experiments involving the high resolution spectrometer (experiment 605) at Fermilab are described. The spectrometer is designed for the study of pairs of particles at large invariant masses and single particles at large transverse momenta. A number of applications of the apparatus in the study of Drell-Yan processes, e.g. transverse momentum measurement, are discussed

  18. Localization-based super-resolution imaging meets high-content screening.

    Science.gov (United States)

    Beghin, Anne; Kechkar, Adel; Butler, Corey; Levet, Florian; Cabillic, Marine; Rossier, Olivier; Giannone, Gregory; Galland, Rémi; Choquet, Daniel; Sibarita, Jean-Baptiste

    2017-12-01

    Single-molecule localization microscopy techniques have proven to be essential tools for quantitatively monitoring biological processes at unprecedented spatial resolution. However, these techniques are very low throughput and are not yet compatible with fully automated, multiparametric cellular assays. This shortcoming is primarily due to the huge amount of data generated during imaging and the lack of software for automation and dedicated data mining. We describe an automated quantitative single-molecule-based super-resolution methodology that operates in standard multiwell plates and uses analysis based on high-content screening and data-mining software. The workflow is compatible with fixed- and live-cell imaging and allows extraction of quantitative data like fluorophore photophysics, protein clustering or dynamic behavior of biomolecules. We demonstrate that the method is compatible with high-content screening using 3D dSTORM and DNA-PAINT based super-resolution microscopy as well as single-particle tracking.

  19. High-resolution RCMs as pioneers for future GCMs

    Science.gov (United States)

    Schar, C.; Ban, N.; Arteaga, A.; Charpilloz, C.; Di Girolamo, S.; Fuhrer, O.; Hoefler, T.; Leutwyler, D.; Lüthi, D.; Piaget, N.; Ruedisuehli, S.; Schlemmer, L.; Schulthess, T. C.; Wernli, H.

    2017-12-01

    Currently large efforts are underway to refine the horizontal resolution of global and regional climate models to O(1 km), with the intent to represent convective clouds explicitly rather than using semi-empirical parameterizations. This refinement will move the governing equations closer to first principles and is expected to reduce the uncertainties of climate models. High resolution is particularly attractive in order to better represent critical cloud feedback processes (e.g. related to global climate sensitivity and extratropical summer convection) and extreme events (such as heavy precipitation events, floods, and hurricanes). The presentation will be illustrated using decade-long simulations at 2 km horizontal grid spacing, some of these covering the European continent on a computational mesh with 1536x1536x60 grid points. To accomplish such simulations, use is made of emerging heterogeneous supercomputing architectures, using a version of the COSMO limited-area weather and climate model that is able to run entirely on GPUs. Results show that kilometer-scale resolution dramatically improves the simulation of precipitation in terms of the diurnal cycle and short-term extremes. The modeling framework is used to address changes of precipitation scaling with climate change. It is argued that already today, modern supercomputers would in principle enable global atmospheric convection-resolving climate simulations, provided appropriately refactored codes were available, and provided solutions were found to cope with the rapidly growing output volume. A discussion will be provided of key challenges affecting the design of future high-resolution climate models. It is suggested that km-scale RCMs should be exploited to pioneer this terrain, at a time when GCMs are not yet available at such resolutions. Areas of interest include the development of new parameterization schemes adequate for km-scale resolution, the exploration of new validation methodologies and data

  20. Methylation-Sensitive High Resolution Melting (MS-HRM).

    Science.gov (United States)

    Hussmann, Dianna; Hansen, Lise Lotte

    2018-01-01

    Methylation-Sensitive High Resolution Melting (MS-HRM) is an in-tube, PCR-based method to detect methylation levels at specific loci of interest. A unique primer design facilitates a high sensitivity of the assays enabling detection of down to 0.1-1% methylated alleles in an unmethylated background.Primers for MS-HRM assays are designed to be complementary to the methylated allele, and a specific annealing temperature enables these primers to anneal both to the methylated and the unmethylated alleles thereby increasing the sensitivity of the assays. Bisulfite treatment of the DNA prior to performing MS-HRM ensures a different base composition between methylated and unmethylated DNA, which is used to separate the resulting amplicons by high resolution melting.The high sensitivity of MS-HRM has proven useful for detecting cancer biomarkers in a noninvasive manner in urine from bladder cancer patients, in stool from colorectal cancer patients, and in buccal mucosa from breast cancer patients. MS-HRM is a fast method to diagnose imprinted diseases and to clinically validate results from whole-epigenome studies. The ability to detect few copies of methylated DNA makes MS-HRM a key player in the quest for establishing links between environmental exposure, epigenetic changes, and disease.

  1. High-resolution MR imaging of talar osteochondral lesions with new classification

    Energy Technology Data Exchange (ETDEWEB)

    Griffith, James Francis; Lau, Domily Ting Yi; Yeung, David Ka Wai [Prince of Wales Hospital, Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Shatin, NT (China); Wong, Margaret Wan Nar [Prince of Wales Hospital, Chinese University of Hong Kong, Department of Orthopaedics and Traumatology, Shatin (China)

    2012-04-15

    Retrospective review of high-resolution MR imaging features of talar dome osteochondral lesions and development of new classification system based on these features. Over the past 7 years, 70 osteochondral lesions of the talar dome from 70 patients (49 males, 21 females, mean age 42 years, range 15-62 years) underwent high-resolution MR imaging with a microscopy coil at 1.5 T. Sixty-one (87%) of 70 lesions were located on the medial central aspect and ten (13%) lesions were located on the lateral central aspect of the talar dome. Features evaluated included cartilage fracture, osteochondral junction separation, subchondral bone collapse, bone:bone separation, and marrow change. Based on these findings, a new five-part grading system was developed. Signal-to-noise characteristics of microscopy coil imaging at 1.5 T were compared to dedicated ankle coil imaging at 3 T. Microscopy coil imaging at 1.5 T yielded 20% better signal-to-noise characteristics than ankle coil imaging at 3 T. High-resolution MR revealed that osteochondral junction separation, due to focal collapse of the subchondral bone, was a common feature, being present in 28 (45%) of 61 medial central osteochondral lesions. Reparative cartilage hypertrophy and bone:bone separation in the absence of cartilage fracture were also common findings. Complete osteochondral separation was uncommon. A new five-part grading system incorporating features revealed by high-resolution MR imaging was developed. High-resolution MRI reveals clinically pertinent features of talar osteochondral lesions, which should help comprehension of symptomatology and enhance clinical decision-making. These features were incorporated in a new MR-based grading system. Whenever possible, symptomatic talar osteochondral lesions should be assessed by high-resolution MR imaging. (orig.)

  2. High-resolution MR imaging of talar osteochondral lesions with new classification

    International Nuclear Information System (INIS)

    Griffith, James Francis; Lau, Domily Ting Yi; Yeung, David Ka Wai; Wong, Margaret Wan Nar

    2012-01-01

    Retrospective review of high-resolution MR imaging features of talar dome osteochondral lesions and development of new classification system based on these features. Over the past 7 years, 70 osteochondral lesions of the talar dome from 70 patients (49 males, 21 females, mean age 42 years, range 15-62 years) underwent high-resolution MR imaging with a microscopy coil at 1.5 T. Sixty-one (87%) of 70 lesions were located on the medial central aspect and ten (13%) lesions were located on the lateral central aspect of the talar dome. Features evaluated included cartilage fracture, osteochondral junction separation, subchondral bone collapse, bone:bone separation, and marrow change. Based on these findings, a new five-part grading system was developed. Signal-to-noise characteristics of microscopy coil imaging at 1.5 T were compared to dedicated ankle coil imaging at 3 T. Microscopy coil imaging at 1.5 T yielded 20% better signal-to-noise characteristics than ankle coil imaging at 3 T. High-resolution MR revealed that osteochondral junction separation, due to focal collapse of the subchondral bone, was a common feature, being present in 28 (45%) of 61 medial central osteochondral lesions. Reparative cartilage hypertrophy and bone:bone separation in the absence of cartilage fracture were also common findings. Complete osteochondral separation was uncommon. A new five-part grading system incorporating features revealed by high-resolution MR imaging was developed. High-resolution MRI reveals clinically pertinent features of talar osteochondral lesions, which should help comprehension of symptomatology and enhance clinical decision-making. These features were incorporated in a new MR-based grading system. Whenever possible, symptomatic talar osteochondral lesions should be assessed by high-resolution MR imaging. (orig.)

  3. High resolution positron tomography

    International Nuclear Information System (INIS)

    Brownell, G.L.; Burnham, C.A.

    1982-01-01

    The limits of spatial resolution in practical positron tomography are examined. The four factors that limit spatial resolution are: positron range; small angle deviation; detector dimensions and properties; statistics. Of these factors, positron range may be considered the fundamental physical limitation since it is independent of instrument properties. The other factors are to a greater or lesser extent dependent on the design of the tomograph

  4. High-intensity xenon plasma discharge lamp for bulk-sensitive high-resolution photoemission spectroscopy.

    Science.gov (United States)

    Souma, S; Sato, T; Takahashi, T; Baltzer, P

    2007-12-01

    We have developed a highly brilliant xenon (Xe) discharge lamp operated by microwave-induced electron cyclotron resonance (ECR) for ultrahigh-resolution bulk-sensitive photoemission spectroscopy (PES). We observed at least eight strong radiation lines from neutral or singly ionized Xe atoms in the energy region of 8.4-10.7 eV. The photon flux of the strongest Xe I resonance line at 8.437 eV is comparable to that of the He Ialpha line (21.218 eV) from the He-ECR discharge lamp. Stable operation for more than 300 h is achieved by efficient air-cooling of a ceramic tube in the resonance cavity. The high bulk sensitivity and high-energy resolution of PES using the Xe lines are demonstrated for some typical materials.

  5. High resolution, position sensitive detector for energetic particle beams

    International Nuclear Information System (INIS)

    Marsh, E.P.; Strathman, M.D.; Reed, D.A.; Odom, R.W.; Morse, D.H.; Pontau, A.E.

    1993-01-01

    The performance and design of an imaging position sensitive, particle beam detector will be presented. The detector is minimally invasive, operates a wide dynamic range (>10 10 ), and exhibits high spatial resolution. The secondary electrons produced when a particle beam passes through a thin foil are imaged using stigmatic ion optics onto a two-dimensional imaging detector. Due to the low scattering cross section of the 6 nm carbon foil the detector is a minimal perturbation on the primary beam. A prototype detector with an image resolution of approximately 5 μm for a field of view of 1 mm has been reported. A higher resolution detector for imaging small beams (<50 μm) with an image resolution of better than 0.5 μm has since been developed and its design is presented. (orig.)

  6. High-resolution mapping of forest carbon stocks in the Colombian Amazon

    Directory of Open Access Journals (Sweden)

    G. P. Asner

    2012-07-01

    Full Text Available High-resolution mapping of tropical forest carbon stocks can assist forest management and improve implementation of large-scale carbon retention and enhancement programs. Previous high-resolution approaches have relied on field plot and/or light detection and ranging (LiDAR samples of aboveground carbon density, which are typically upscaled to larger geographic areas using stratification maps. Such efforts often rely on detailed vegetation maps to stratify the region for sampling, but existing tropical forest maps are often too coarse and field plots too sparse for high-resolution carbon assessments. We developed a top-down approach for high-resolution carbon mapping in a 16.5 million ha region (> 40% of the Colombian Amazon – a remote landscape seldom documented. We report on three advances for large-scale carbon mapping: (i employing a universal approach to airborne LiDAR-calibration with limited field data; (ii quantifying environmental controls over carbon densities; and (iii developing stratification- and regression-based approaches for scaling up to regions outside of LiDAR coverage. We found that carbon stocks are predicted by a combination of satellite-derived elevation, fractional canopy cover and terrain ruggedness, allowing upscaling of the LiDAR samples to the full 16.5 million ha region. LiDAR-derived carbon maps have 14% uncertainty at 1 ha resolution, and the regional map based on stratification has 28% uncertainty in any given hectare. High-resolution approaches with quantifiable pixel-scale uncertainties will provide the most confidence for monitoring changes in tropical forest carbon stocks. Improved confidence will allow resource managers and decision makers to more rapidly and effectively implement actions that better conserve and utilize forests in tropical regions.

  7. The implementation of sea ice model on a regional high-resolution scale

    Science.gov (United States)

    Prasad, Siva; Zakharov, Igor; Bobby, Pradeep; McGuire, Peter

    2015-09-01

    The availability of high-resolution atmospheric/ocean forecast models, satellite data and access to high-performance computing clusters have provided capability to build high-resolution models for regional ice condition simulation. The paper describes the implementation of the Los Alamos sea ice model (CICE) on a regional scale at high resolution. The advantage of the model is its ability to include oceanographic parameters (e.g., currents) to provide accurate results. The sea ice simulation was performed over Baffin Bay and the Labrador Sea to retrieve important parameters such as ice concentration, thickness, ridging, and drift. Two different forcing models, one with low resolution and another with a high resolution, were used for the estimation of sensitivity of model results. Sea ice behavior over 7 years was simulated to analyze ice formation, melting, and conditions in the region. Validation was based on comparing model results with remote sensing data. The simulated ice concentration correlated well with Advanced Microwave Scanning Radiometer for EOS (AMSR-E) and Ocean and Sea Ice Satellite Application Facility (OSI-SAF) data. Visual comparison of ice thickness trends estimated from the Soil Moisture and Ocean Salinity satellite (SMOS) agreed with the simulation for year 2010-2011.

  8. The dose dependency of the over-dispersion of quartz OSL single grain dose distributions

    DEFF Research Database (Denmark)

    Thomsen, Kristina Jørkov; Murray, Andrew S.; Jain, Mayank

    2012-01-01

    The use of single grain quartz OSL dating has become widespread over the past decade, particularly with application to samples likely to have been incompletely bleached before burial. By reducing the aliquot size to a single grain the probability of identifying the grain population most likely...... to have been well-bleached at deposition is maximised and thus the accuracy with which the equivalent dose can be determined is – at least in principle – improved. However, analysis of single grain dose distributions requires knowledge of the dispersion of the well-bleached part of the dose distribution....... This can be estimated by measurement of a suitable analogue, e.g. a well-bleached aeolian sample, but this requires such an analogue to be available, and in addition the assumptions that the sample is in fact a) well-bleached, and b) has a similar dose rate heterogeneity to the fossil deposit. Finally...

  9. Performance of a high resolution cavity beam position monitor system

    Science.gov (United States)

    Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Pete; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Honda, Yosuke; Kolomensky, Yury; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; Thomson, Mark; Urakawa, Junji; Vogel, Vladimir; Ward, David; White, Glen

    2007-07-01

    It has been estimated that an RF cavity Beam Position Monitor (BPM) could provide a position measurement resolution of less than 1 nm. We have developed a high resolution cavity BPM and associated electronics. A triplet comprised of these BPMs was installed in the extraction line of the Accelerator Test Facility (ATF) at the High Energy Accelerator Research Organization (KEK) for testing with its ultra-low emittance beam. The three BPMs were each rigidly mounted inside an alignment frame on six variable-length struts which could be used to move the BPMs in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, we have demonstrated a position resolution of 15.6 nm and a tilt resolution of 2.1 μrad over a dynamic range of approximately ±20 μm.

  10. The high resolution shear wave seismic reflection technique

    International Nuclear Information System (INIS)

    Johnson, W.J.; Clark, J.C.

    1991-04-01

    This report presents the state-of-the-art of the high resolution S-wave reflection technique. Published and unpublished literature has been reviewed and discussions have been held with experts. Result is to confirm that the proposed theoretical and practical basis for identifying aquifer systems using both P- and S-wave reflections is sound. Knowledge of S-wave velocity and P-wave velocity is a powerful tool for assessing the fluid characteristics of subsurface layers. Material properties and lateral changes in material properties such as change from clay to sand, can be inferred from careful dual evaluation of P and S-wave records. The high resolution S-wave reflection technique has seen its greatest application to date as part of geotechnical studies for building foundations in the Far East. Information from this type of study has been evaluated and will be incorporated in field studies. In particular, useful information regarding S-wave sources, noise suppression and recording procedures will be incorporated within the field studies. Case histories indicate that the best type of site for demonstrating the power of the high resolution S-wave technique will be in unconsolidated soil without excessive structural complexities. More complex sites can form the basis for subsequent research after the basic principles of the technique can be established under relatively uncomplicated conditions

  11. Charge-coupled devices for particle detection with high spatial resolution

    International Nuclear Information System (INIS)

    Farley, F.J.; Damerell, C.J.S.; Gillman, A.R.; Wickens, F.J.

    1980-10-01

    The results of a study of the possible application of a thin microelectronic device (the charge-coupled device) to high energy physics as particle detectors with good spatial resolution which can distinguish between tracks emerging from the primary vertex and those from secondary vertices due to the decay of short lived particles with higher flavours, are reported. Performance characteristics indicating the spatial resolution, particle discrimination, time resolution, readout time and lifetime of such detectors have been obtained. (U.K.)

  12. Rapid calibrated high-resolution hyperspectral imaging using tunable laser source

    Science.gov (United States)

    Nguyen, Lam K.; Margalith, Eli

    2009-05-01

    We present a novel hyperspectral imaging technique based on tunable laser technology. By replacing the broadband source and tunable filters of a typical NIR imaging instrument, several advantages are realized, including: high spectral resolution, highly variable field-of-views, fast scan-rates, high signal-to-noise ratio, and the ability to use optical fiber for efficient and flexible sample illumination. With this technique, high-resolution, calibrated hyperspectral images over the NIR range can be acquired in seconds. The performance of system features will be demonstrated on two example applications: detecting melamine contamination in wheat gluten and separating bovine protein from wheat protein in cattle feed.

  13. High Resolution Higher Energy X-ray Microscope for Mesoscopic Materials

    International Nuclear Information System (INIS)

    Snigireva, I; Snigirev, A

    2013-01-01

    We developed a novel X-ray microscopy technique to study mesoscopically structured materials, employing compound refractive lenses. The easily seen advantage of lens-based methodology is the possibility to retrieve high resolution diffraction pattern and real-space images in the same experimental setup. Methodologically the proposed approach is similar to the studies of crystals by high resolution transmission electron microscopy. The proposed microscope was applied for studying of mesoscopic materials such as natural and synthetic opals, inverted photonic crystals

  14. Solutions on high-resolution multiple configuration system sensors

    Science.gov (United States)

    Liu, Hua; Ding, Quanxin; Guo, Chunjie; Zhou, Liwei

    2014-11-01

    For aim to achieve an improved resolution in modern image domain, a method of continuous zoom multiple configuration, with a core optics is attempt to establish model by novel principle on energy transfer and high accuracy localization, by which the system resolution can be improved with a level in nano meters. A comparative study on traditional vs modern methods can demonstrate that the dialectical relationship and their balance is important, among Merit function, Optimization algorithms and Model parameterization. The effect of system evaluated criterion that MTF, REA, RMS etc. can support our arguments qualitatively.

  15. Development of high-energy resolution inverse photoemission technique

    International Nuclear Information System (INIS)

    Asakura, D.; Fujii, Y.; Mizokawa, T.

    2005-01-01

    We developed a new inverse photoemission (IPES) machine based on a new idea to improve the energy resolution: off-plane Eagle mounting of the optical system in combination with dispersion matching between incoming electron and outgoing photon. In order to achieve dispersion matching, we have employed a parallel plate electron source and have investigated whether the electron beam is obtained as expected. In this paper, we present the principle and design of the new IPES method and report the current status of the high-energy resolution IPES machine

  16. High-Resolution Reciprocal Space Mapping for Characterizing Deformation Structures

    DEFF Research Database (Denmark)

    Pantleon, Wolfgang; Wejdemann, Christian; Jakobsen, Bo

    2014-01-01

    With high-angular resolution three-dimensional X-ray diffraction (3DXRD), quantitative information is gained about dislocation structures in individual grains in the bulk of a macroscopic specimen by acquiring reciprocal space maps. In high-resolution 3D reciprocal space maps of tensile......-deformed copper, individual, almost dislocation-free subgrains are identified from high-intensity peaks and distinguished by their unique combination of orientation and elastic strain; dislocation walls manifest themselves as a smooth cloud of lower intensity. The elastic strain shows only minor variations within...... dynamics is followed in situ during varying loading conditions by reciprocal space mapping: during uninterrupted tensile deformation, formation of subgrains is observed concurrently with broadening of Bragg reflections shortly after the onset of plastic deformation. When the traction is terminated, stress...

  17. Self-triggered image intensifier tube for high-resolution UHECR imaging detector

    CERN Document Server

    Sasaki, M; Jobashi, M

    2003-01-01

    The authors have developed a self-triggered image intensifier tube with high-resolution imaging capability. An image detected by a first image intensifier tube as an electrostatic lens with a photocathode diameter of 100 mm is separated by a half-mirror into a path for CCD readout (768x494 pixels) and a fast control to recognize and trigger the image. The proposed system provides both a high signal-to-noise ratio to improve single photoelectron detection and excellent spatial resolution between 207 and 240 mu m rendering this device a potentially essential tool for high-energy physics and astrophysics experiments, as well as high-speed photography. When combined with a 1-arcmin resolution optical system with 50 deg. field-of-view proposed by the present authors, the observation of ultra high-energy cosmic rays and high-energy neutrinos using this device is expected, leading to revolutionary progress in particle astrophysics as a complementary technique to traditional astronomical observations at multiple wave...

  18. High spectral resolution X-ray observations of AGN

    NARCIS (Netherlands)

    Kaastra, J.S.

    2008-01-01

    brief overview of some highlights of high spectral resolution X-ray observations of AGN is given, mainly obtained with the RGS of XMM-Newton. Future prospects for such observations with XMM-Newton are given.

  19. A high resolution 16 k multi-channel analyzer PC add-on card

    International Nuclear Information System (INIS)

    Kulkarni, C.P.; Paulson, Molly; Vaidya, P.P.

    2001-01-01

    This paper describes the system details of a 16 K channel resolution Multi-Channel Analyzer (MCA) developed at Electronics Division, BARC, which is used in high resolution nuclear spectroscopy systems for pulse height analysis. The high resolution data acquisition PC add-on card is architectured using a state of the art digital circuit design technology which makes use of a Field Programmable Gate Array (FPGA), and some of the most modern and advanced analog counterparts like low power, high speed and high precision comparators, Op-amps, ADCs and DACs etc. The 16 K MCA card gives an economic, compact, and low power alternative for nuclear pulse spectroscopy use. (author)

  20. An angle encoder for super-high resolution and super-high accuracy using SelfA

    International Nuclear Information System (INIS)

    Watanabe, Tsukasa; Kon, Masahito; Nabeshima, Nobuo; Taniguchi, Kayoko

    2014-01-01

    Angular measurement technology at high resolution for applications such as in hard disk drive manufacturing machines, precision measurement equipment and aspherical process machines requires a rotary encoder with high accuracy, high resolution and high response speed. However, a rotary encoder has angular deviation factors during operation due to scale error or installation error. It has been assumed to be impossible to achieve accuracy below 0.1″ in angular measurement or control after the installation onto the rotating axis. Self-calibration (Lu and Trumper 2007 CIRP Ann. 56 499; Kim et al 2011 Proc. MacroScale; Probst 2008 Meas. Sci. Technol. 19 015101; Probst et al Meas. Sci. Technol. 9 1059; Tadashi and Makoto 1993 J. Robot. Mechatronics 5 448; Ralf et al 2006 Meas. Sci. Technol. 17 2811) and cross-calibration (Probst et al 1998 Meas. Sci. Technol. 9 1059; Just et al 2009 Precis. Eng. 33 530; Burnashev 2013 Quantum Electron. 43 130) technologies for a rotary encoder have been actively discussed on the basis of the principle of circular closure. This discussion prompted the development of rotary tables which achieve reliable and high accuracy angular verification. We apply these technologies for the development of a rotary encoder not only to meet the requirement of super-high accuracy but also to meet that of super-high resolution. This paper presents the development of an encoder with 2 21 = 2097 152 resolutions per rotation (360°), that is, corresponding to a 0.62″ signal period, achieved by the combination of a laser rotary encoder supplied by Magnescale Co., Ltd and a self-calibratable encoder (SelfA) supplied by The National Institute of Advanced Industrial Science and Technology (AIST). In addition, this paper introduces the development of a rotary encoder to guarantee ±0.03″ accuracy at any point of the interpolated signal, with respect to the encoder at the minimum resolution of 2 33 , that is, corresponding to a 0.0015″ signal period

  1. Assessment of prediction skill in equatorial Pacific Ocean in high resolution model of CFS

    Science.gov (United States)

    Arora, Anika; Rao, Suryachandra A.; Pillai, Prasanth; Dhakate, Ashish; Salunke, Kiran; Srivastava, Ankur

    2018-01-01

    The effect of increasing atmospheric resolution on prediction skill of El Niño southern oscillation phenomenon in climate forecast system model is explored in this paper. Improvement in prediction skill for sea surface temperature (SST) and winds at all leads compared to low resolution model in the tropical Indo-Pacific basin is observed. High resolution model is able to capture extreme events reasonably well. As a result, the signal to noise ratio is improved in the high resolution model. However, spring predictability barrier (SPB) for summer months in Nino 3 and Nino 3.4 region is stronger in high resolution model, in spite of improvement in overall prediction skill and dynamics everywhere else. Anomaly correlation coefficient of SST in high resolution model with observations in Nino 3.4 region targeting boreal summer months when predicted at lead times of 3-8 months in advance decreased compared its lower resolution counterpart. It is noted that higher variance of winds predicted in spring season over central equatorial Pacific compared to observed variance of winds results in stronger than normal response on subsurface ocean, hence increases SPB for boreal summer months in high resolution model.

  2. High-Resolution Near Real-Time Drought Monitoring in South Asia

    Science.gov (United States)

    Aadhar, S.; Mishra, V.

    2017-12-01

    Drought in South Asia affect food and water security and pose challenges for millions of people. For policy-making, planning and management of water resources at the sub-basin or administrative levels, high-resolution datasets of precipitation and air temperature are required in near-real time. Here we develop a high resolution (0.05 degree) bias-corrected precipitation and temperature data that can be used to monitor near real-time drought conditions over South Asia. Moreover, the dataset can be used to monitor climatic extremes (heat waves, cold waves, dry and wet anomalies) in South Asia. A distribution mapping method was applied to correct bias in precipitation and air temperature (maximum and minimum), which performed well compared to the other bias correction method based on linear scaling. Bias-corrected precipitation and temperature data were used to estimate Standardized precipitation index (SPI) and Standardized Precipitation Evapotranspiration Index (SPEI) to assess the historical and current drought conditions in South Asia. We evaluated drought severity and extent against the satellite-based Normalized Difference Vegetation Index (NDVI) anomalies and satellite-driven Drought Severity Index (DSI) at 0.05˚. We find that the bias-corrected high-resolution data can effectively capture observed drought conditions as shown by the satellite-based drought estimates. High resolution near real-time dataset can provide valuable information for decision-making at district and sub- basin levels.

  3. New detector developments for high resolution positron emission tomography

    International Nuclear Information System (INIS)

    Ziegler, S.I.; Pichler, B.; Lorenz, E.

    1998-01-01

    The strength of quantitative, functional imaging using positron emission tomography, specially in small animals, is limited due to the spatial resolution. Therefore, various tomograph designs employing new scintillators, light sensors, or coincidence electronic are investigated to improve resolution without losses in sensitivity. Luminous scintillators with short light decay time in combination with novel readout schemes using photomultipliers or semiconductor detectors are currently tested by several groups and are implemented in tomographs for small animals. This review summarises the state of development in high resolution positron emission tomography with a detailed description of a system incorporating avalanche photodiode arrays and small scintillation crystals. (orig.) [de

  4. High Resolution Thz and FIR Spectroscopy of SOCl_2

    Science.gov (United States)

    Martin-Drumel, M. A.; Cuisset, A.; Sadovskii, D. A.; Mouret, G.; Hindle, F.; Pirali, O.

    2013-06-01

    Thionyl chloride (SOCl_2) is an extremely powerful oxidant widely used in industrial processes and playing a role in the chemistry of the atmosphere. In addition, it has a molecular configuration similar to that of phosgene (COCl_2), and is therefore of particular interest for security and defense applications. Low resolution vibrational spectra of gas phase SOCl_2 as well as high resolution pure rotational transitions up to 25 GHz have previously been investigated. To date no high resolution data are reported at frequencies higher than 25 GHz. We have investigated the THz absorption spectrum of SOCl_2 in the spectral region 70-650 GHz using a frequency multiplier chain coupled to a 1 m long single path cell containing a pressure of about 15 μbar. At the time of the writing, about 8000 pure rotational transitions of SO^{35}Cl_2 with highest J and K_a values of 110 and 50 respectively have been assigned on the spectrum. We have also recorded the high resolution FIR spectra of SOCl_2 in the spectral range 50-700 wn using synchrotron radiation at the AILES beamline of SOLEIL facility. A White-type cell aligned with an absorption path length of 150 m has been used to record, at a resolution of 0.001 wn, two spectra at pressures of 5 and 56 μbar of SOCl_2. On these spectra all FIR modes of SOCl_2 are observed (ν_2 to ν_6) and present a resolved rotational structure. Their analysis is in progress. T. J. Johnson et al., J. Phys. Chem. A 107, 6183 (2003) D. E. Martz and R. T. Lagemann, J. Chem. Phys. 22,1193 (1954) H. S. P. Müller and M. C. L. Gerry, J. Chem. Soc. Faraday Trans. 90, 3473 (1994)

  5. A high resolution large dynamic range TDC circuit implementation

    International Nuclear Information System (INIS)

    Lei Wuhu; Liu Songqiu; Ye Weiguo; Han Hui; Li Pengyu

    2003-01-01

    Time measurement technology is usually used in nuclear experimentation. There are many methods of time measurement. The implementation method of Time to Digital Conversion (TDC) by means of electronic is a classical technology. The range and resolution of TDC is different according with different usage. A wide range and high resolution TDC circuit, including its theory and implementation way, is introduced in this paper. The test result is also given. (authors)

  6. A high resolution large dynamic range TDC circuit implementation

    International Nuclear Information System (INIS)

    Lei Wuhu; Liu Songqiu; Li Pengyu; Han Hui; Ye Yanlin

    2005-01-01

    Time measurement technology is usually used in nuclear experimentation. There are many methods of time measurement. The implementation method of Time to Digital Conversion (TDC) by means of electronics is a classical technology. The range and resolution of TDC is different according with different usage. A wide range and high resolution TDC circuit, including its theory and implementation way, is introduced in this paper. The test result is also given. (authors)

  7. High-resolution retinal imaging using adaptive optics and Fourier-domain optical coherence tomography

    Science.gov (United States)

    Olivier, Scot S.; Werner, John S.; Zawadzki, Robert J.; Laut, Sophie P.; Jones, Steven M.

    2010-09-07

    This invention permits retinal images to be acquired at high speed and with unprecedented resolution in three dimensions (4.times.4.times.6 .mu.m). The instrument achieves high lateral resolution by using adaptive optics to correct optical aberrations of the human eye in real time. High axial resolution and high speed are made possible by the use of Fourier-domain optical coherence tomography. Using this system, we have demonstrated the ability to image microscopic blood vessels and the cone photoreceptor mosaic.

  8. High-heat tank safety issue resolution program plan

    International Nuclear Information System (INIS)

    Wang, O.S.

    1993-12-01

    The purpose of this program plan is to provide a guide for selecting corrective actions that will mitigate and/or remediate the high-heat waste tank safety issue for single-shell tank (SST) 241-C-106. This program plan also outlines the logic for selecting approaches and tasks to mitigate and resolve the high-heat safety issue. The identified safety issue for high-heat tank 241-C-106 involves the potential release of nuclear waste to the environment as the result of heat-induced structural damage to the tank's concrete, if forced cooling is interrupted for extended periods. Currently, forced ventilation with added water to promote thermal conductivity and evaporation cooling is used to cool the waste. At this time, the only viable solution identified to resolve this safety issue is the removal of heat generating waste in the tank. This solution is being aggressively pursued as the permanent solution to this safety issue and also to support the present waste retrieval plan. Tank 241-C-106 has been selected as the first SST for retrieval. The program plan has three parts. The first part establishes program objectives and defines safety issues, drivers, and resolution criteria and strategy. The second part evaluates the high-heat safety issue and its mitigation and remediation methods and alternatives according to resolution logic. The third part identifies major tasks and alternatives for mitigation and resolution of the safety issue. Selected tasks and best-estimate schedules are also summarized in the program plan

  9. Mastering high resolution tip-enhanced Raman spectroscopy: towards a shift of perception.

    Science.gov (United States)

    Richard-Lacroix, Marie; Zhang, Yao; Dong, Zhenchao; Deckert, Volker

    2017-07-03

    Recent years have seen tremendous improvement of our understanding of high resolution reachable in TERS experiments, forcing us to re-evaluate our understanding of the intrinsic limits of this field, but also exposing several inconsistencies. On the one hand, more and more recent experimental results have provided us with clear indications of spatial resolutions down to a few nanometres or even on the subnanometre scale. Moreover, lessons learned from recent theoretical investigations clearly support such high resolutions, and vice versa the obvious theoretical impossibility to evade high resolution from a purely plasmonic point of view. On the other hand, most of the published TERS results still, to date, claim a resolution on the order of tens of nanometres that would be somehow limited by the tip apex, a statement well accepted for the past 2 decades. Overall, this now leads the field to a fundamental question: how can this divergence be justified? The answer to this question brings up an equally critical one: how can this gap be bridged? This review aims at raising a fundamental discussion related to the resolution limits of tip-enhanced Raman spectroscopy, at revisiting our comprehension of the factors limiting it both from a theoretical and an experimental point of view and at providing indications on how to move the field ahead. It is our belief that a much deeper understanding of the real accessible lateral resolution in TERS and the practical factors that limit them will simultaneously help us to fully explore the potential of this technique for studying nanoscale features in organic, inorganic and biological systems, and also to improve both the reproducibility and the accuracy of routine TERS studies. A significant improvement of our comprehension of the accessible resolution in TERS is thus critical for a broad audience, even in certain contexts where high resolution TERS is not the desired outcome.

  10. High resolution, position sensitive detector for energetic particle beams

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, E P [Charles Evans and Associates, Redwood City, CA (United States); Strathman, M D [Charles Evans and Associates, Redwood City, CA (United States); Reed, D A [Charles Evans and Associates, Redwood City, CA (United States); Odom, R W [Charles Evans and Associates, Redwood City, CA (United States); Morse, D H [Sandia National Labs., Livermore, CA (United States); Pontau, A E [Sandia National Labs., Livermore, CA (United States)

    1993-05-01

    The performance and design of an imaging position sensitive, particle beam detector will be presented. The detector is minimally invasive, operates a wide dynamic range (>10[sup 10]), and exhibits high spatial resolution. The secondary electrons produced when a particle beam passes through a thin foil are imaged using stigmatic ion optics onto a two-dimensional imaging detector. Due to the low scattering cross section of the 6 nm carbon foil the detector is a minimal perturbation on the primary beam. A prototype detector with an image resolution of approximately 5 [mu]m for a field of view of 1 mm has been reported. A higher resolution detector for imaging small beams (<50 [mu]m) with an image resolution of better than 0.5 [mu]m has since been developed and its design is presented. (orig.)

  11. WRF high resolution dynamical downscaling of ERA-Interim for Portugal

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Pedro M.M. [University of Lisbon, Instituto Dom Luiz, Lisbon (Portugal); Faculdade de Ciencias da Universidade de Lisboa, Lisbon (Portugal); Cardoso, Rita M.; Miranda, Pedro M.A.; Medeiros, Joana de [University of Lisbon, Instituto Dom Luiz, Lisbon (Portugal); Belo-Pereira, Margarida; Espirito-Santo, Fatima [Instituto de Meteorologia, Lisbon (Portugal)

    2012-11-15

    This study proposes a dynamically downscaled climatology of Portugal, produced by a high resolution (9 km) WRF simulation, forced by 20 years of ERA-Interim reanalysis (1989-2008), nested in an intermediate domain with 27 km of resolution. The Portuguese mainland is characterized by large precipitation gradients, with observed mean annual precipitation ranging from about 400 to over 2,200 mm, with a very wet northwest and rather dry southeast, largely explained by orographic processes. Model results are compared with all available stations with continuous records, comprising daily information in 32 stations for temperature and 308 for precipitation, through the computation of mean climatologies, standard statistical errors on daily to seasonally timescales, and distributions of extreme events. Results show that WRF at 9 km outperforms ERA-Interim in all analyzed variables, with good results in the representation of the annual cycles in each region. The biases of minimum and maximum temperature are reduced, with improvement of the description of temperature variability at the extreme range of its distribution. The largest gain of the high resolution simulations is visible in the rainiest regions of Portugal, where orographic enhancement is crucial. These improvements are striking in the high ranking percentiles in all seasons, describing extreme precipitation events. WRF results at 9 km compare favorably with published results supporting its use as a high-resolution regional climate model. This higher resolution allows a better representation of extreme events that are of major importance to develop mitigation/adaptation strategies by policy makers and downstream users of regional climate models in applications such as flash floods or heat waves. (orig.)

  12. High-resolution near real-time drought monitoring in South Asia

    OpenAIRE

    Aadhar, Saran; Mishra, Vimal

    2017-01-01

    Drought in South Asia affect food and water security and pose challenges for millions of people. For policy-making, planning, and management of water resources at sub-basin or administrative levels, high-resolution datasets of precipitation and air temperature are required in near-real time. We develop a high-resolution (0.05°) bias-corrected precipitation and temperature data that can be used to monitor near real-time drought conditions over South Asia. Moreover, the dataset can be used to m...

  13. High resolution estimates of the corrosion risk for cultural heritage in Italy

    International Nuclear Information System (INIS)

    De Marco, Alessandra; Screpanti, Augusto; Mircea, Mihaela; Piersanti, Antonio; Proietti, Chiara; Fornasier, M. Francesca

    2017-01-01

    Air pollution plays a pivotal role in the deterioration of many materials used in buildings and cultural monuments causing an inestimable damage. This study aims to estimate the impacts of air pollution (SO 2 , HNO 3 , O 3 , PM 10 ) and meteorological conditions (temperature, precipitation, relative humidity) on limestone, copper and bronze based on high resolution air quality data-base produced with AMS-MINNI modelling system over the Italian territory over the time period 2003–2010. A comparison between high resolution data (AMS-MINNI grid, 4 × 4 km) and low resolution data (EMEP grid, 50 × 50 km) has been performed. Our results pointed out that the corrosion levels for limestone, copper and bronze are decreased in Italy from 2003 to 2010 in relation to decrease of pollutant concentrations. However, some problem related to air pollution persists especially in Northern and Southern Italy. In particular, PM 10 and HNO 3 are considered the main responsible for limestone corrosion. Moreover, the high resolution data (AMS-MINNI) allowed the identification of risk areas that are not visible with the low resolution data (EMEP modelling system) in all considered years and, especially, in the limestone case. Consequently, high resolution air quality simulations are suitable to provide concrete benefits in providing information for national effective policy against corrosion risk for cultural heritage, also in the context of climate changes that are affecting strongly Mediterranean basin. - Highlights: • Air pollution plays a pivotal role in the deterioration of cultural materials. • Limestone, copper and bronze corrosion levels decreased in Italy from 2003 to 2010. • PM 10 is considered the main responsible for limestone corrosion in Northern Italy. • HNO3 is considered the main responsible for limestone corrosion in all analyzed years. • High-resolution data are particularly useful to define area at risk for corrosion. - Importance of the high-resolution

  14. High-resolution computer-aided moire

    Science.gov (United States)

    Sciammarella, Cesar A.; Bhat, Gopalakrishna K.

    1991-12-01

    This paper presents a high resolution computer assisted moire technique for the measurement of displacements and strains at the microscopic level. The detection of micro-displacements using a moire grid and the problem associated with the recovery of displacement field from the sampled values of the grid intensity are discussed. A two dimensional Fourier transform method for the extraction of displacements from the image of the moire grid is outlined. An example of application of the technique to the measurement of strains and stresses in the vicinity of the crack tip in a compact tension specimen is given.

  15. High flux and high resolution VUV beam line for synchrotron radiation

    International Nuclear Information System (INIS)

    Wilcke, H.; Boehmer, W.; Schwentner, N.

    1982-04-01

    A beam line has been optimized for high flux and high resolution in the wavelength range from 30 nm to 300 nm. Sample chambers for luminescence spectroscopy on gaseous, liquid and solid samples and for photoelectron spectroscopy have been integrated. The synchrotron radiation from the storage ring DORIS (at DESY, Hamburg) emitted into 50 mrad in horizontal and into 2.2 mrad in vertical direction is focused by a cylindrical and a plane elliptical mirror into the entrance slit of a 2m normal incidence monochromator. The light flux from the exit slit is focused by a rotational elliptic mirror onto the sample yielding a size of the light spot of 4 x 0.15 mm 2 . The light flux at the sample reaches 7 x 10 12 photons nm -1 s -1 at 8 eV photon energy for a current of 100 mA in DORIS. A resolution of 0.007 nm has been obtained. (orig.)

  16. Pyrosequencing™ : A one-step method for high resolution HLA typing

    Directory of Open Access Journals (Sweden)

    Marincola Francesco M

    2003-11-01

    Full Text Available Abstract While the use of high-resolution molecular typing in routine matching of human leukocyte antigens (HLA is expected to improve unrelated donor selection and transplant outcome, the genetic complexity of HLA still makes the current methodology limited and laborious. Pyrosequencing™ is a gel-free, sequencing-by-synthesis method. In a Pyrosequencing reaction, nucleotide incorporation proceeds sequentially along each DNA template at a given nucleotide dispensation order (NDO that is programmed into a pyrosequencer. Here we describe the design of a NDO that generates a pyrogram unique for any given allele or combination of alleles. We present examples of unique pyrograms generated from each of two heterozygous HLA templates, which would otherwise remain cis/trans ambiguous using standard sequencing based typing (SBT method. In addition, we display representative data that demonstrate long read and linear signal generation. These features are prerequisite of high-resolution typing and automated data analysis. In conclusion Pyrosequencing is a one-step method for high resolution DNA typing.

  17. Development of high resolution Michelson interferometer for stable phase-locked ultrashort pulse pair generation.

    Science.gov (United States)

    Okada, Takumi; Komori, Kazuhiro; Goshima, Keishiro; Yamauchi, Shohgo; Morohashi, Isao; Sugaya, Takeyoshi; Ogura, Mutsuo; Tsurumachi, Noriaki

    2008-10-01

    We developed a high resolution Michelson interferometer with a two-frequency He-Ne laser positioning system in order to stabilize the relative phase of a pulse pair. The control resolution corresponded to a 12 as time resolution or a phase of 1.5 degrees at 900 nm. This high resolution Michelson interferometer can generate a phase-locked pulse pair either with a specific relative phase such as 0 or pi radians or with an arbitrary phase. Coherent control of an InAs self-assembled quantum dot was demonstrated using the high resolution Michelson interferometer with a microspectroscopy system.

  18. Study on the performance of large area MRPC with high position resolution

    Energy Technology Data Exchange (ETDEWEB)

    Yue Qian, E-mail: yueq@mail.tsinghua.edu.cn [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education (China); Wu Yucheng; Li Yuanjing; Ye Jin; Cheng Jianping; Wang Yi; Li Jin [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education (China)

    2012-01-01

    Multi-gap resistive plate chamber (MRPC), which is mostly developed in high energy physics domain with excellent time resolution, is also highlighted in imaging applications. A set of 50 cm Multiplication-Sign 50 cm large area MRPC with high position resolution was successfully developed by our group and different experiments have been done to test its performances. Cosmic ray muons were used to do the test and proper high voltage and working gas were chosen. Data analysis indicates its good detection efficiency and good position resolution, which encourages further study of its application in RPC-PET and muon tomography.

  19. High-resolution satellite imagery is an important yet underutilized resource in conservation biology.

    Science.gov (United States)

    Boyle, Sarah A; Kennedy, Christina M; Torres, Julio; Colman, Karen; Pérez-Estigarribia, Pastor E; de la Sancha, Noé U

    2014-01-01

    Technological advances and increasing availability of high-resolution satellite imagery offer the potential for more accurate land cover classifications and pattern analyses, which could greatly improve the detection and quantification of land cover change for conservation. Such remotely-sensed products, however, are often expensive and difficult to acquire, which prohibits or reduces their use. We tested whether imagery of high spatial resolution (≤5 m) differs from lower-resolution imagery (≥30 m) in performance and extent of use for conservation applications. To assess performance, we classified land cover in a heterogeneous region of Interior Atlantic Forest in Paraguay, which has undergone recent and dramatic human-induced habitat loss and fragmentation. We used 4 m multispectral IKONOS and 30 m multispectral Landsat imagery and determined the extent to which resolution influenced the delineation of land cover classes and patch-level metrics. Higher-resolution imagery more accurately delineated cover classes, identified smaller patches, retained patch shape, and detected narrower, linear patches. To assess extent of use, we surveyed three conservation journals (Biological Conservation, Biotropica, Conservation Biology) and found limited application of high-resolution imagery in research, with only 26.8% of land cover studies analyzing satellite imagery, and of these studies only 10.4% used imagery ≤5 m resolution. Our results suggest that high-resolution imagery is warranted yet under-utilized in conservation research, but is needed to adequately monitor and evaluate forest loss and conversion, and to delineate potentially important stepping-stone fragments that may serve as corridors in a human-modified landscape. Greater access to low-cost, multiband, high-resolution satellite imagery would therefore greatly facilitate conservation management and decision-making.

  20. Utilization of Short-Simulations for Tuning High-Resolution Climate Model

    Science.gov (United States)

    Lin, W.; Xie, S.; Ma, P. L.; Rasch, P. J.; Qian, Y.; Wan, H.; Ma, H. Y.; Klein, S. A.

    2016-12-01

    Many physical parameterizations in atmospheric models are sensitive to resolution. Tuning the models that involve a multitude of parameters at high resolution is computationally expensive, particularly when relying primarily on multi-year simulations. This work describes a complementary set of strategies for tuning high-resolution atmospheric models, using ensembles of short simulations to reduce the computational cost and elapsed time. Specifically, we utilize the hindcast approach developed through the DOE Cloud Associated Parameterization Testbed (CAPT) project for high-resolution model tuning, which is guided by a combination of short (tests have been found to be effective in numerous previous studies in identifying model biases due to parameterized fast physics, and we demonstrate that it is also useful for tuning. After the most egregious errors are addressed through an initial "rough" tuning phase, longer simulations are performed to "hone in" on model features that evolve over longer timescales. We explore these strategies to tune the DOE ACME (Accelerated Climate Modeling for Energy) model. For the ACME model at 0.25° resolution, it is confirmed that, given the same parameters, major biases in global mean statistics and many spatial features are consistent between Atmospheric Model Intercomparison Project (AMIP)-type simulations and CAPT-type hindcasts, with just a small number of short-term simulations for the latter over the corresponding season. The use of CAPT hindcasts to find parameter choice for the reduction of large model biases dramatically improves the turnaround time for the tuning at high resolution. Improvement seen in CAPT hindcasts generally translates to improved AMIP-type simulations. An iterative CAPT-AMIP tuning approach is therefore adopted during each major tuning cycle, with the former to survey the likely responses and narrow the parameter space, and the latter to verify the results in climate context along with assessment in

  1. Validation of High-resolution Climate Simulations over Northern Europe.

    Science.gov (United States)

    Muna, R. A.

    2005-12-01

    Two AMIP2-type (Gates 1992) experiments have been performed with climate versions of ARPEGE/IFS model examine for North Atlantic North Europe, and Norwegian region and analyzed the effect of increasing resolution on the simulated biases. The ECMWF reanalysis or ERA-15 has been used to validate the simulations. Each of the simulations is an integration of the period 1979 to 1996. The global simulations used observed monthly mean sea surface temperatures (SST) as lower boundary condition. All aspects but the horizontal resolutions are similar in the two simulations. The first simulation has a uniform horizontal resolution of T63L. The second one has a variable resolution (T106Lc3) with the highest resolution in the Norwegian Sea. Both simulations have 31 vertical layers in the same locations. For each simulation the results were divided into two seasons: winter (DJF) and summer (JJA). The parameters investigated were mean sea level pressure, geopotential and temperature at 850 hPa and 500 hPa. To find out the causes of temperature bias during summer, latent and sensible heat flux, total cloud cover and total precipitation were analyzed. The high-resolution simulation exhibits more or less realistic climate over Nordic, Artic and European region. The overall performance of the simulations shows improvements of generally all fields investigated with increasing resolution over the target area both in winter (DJF) and summer (JJA).

  2. Development and features of an X-ray detector with high spatial resolution

    International Nuclear Information System (INIS)

    Hartmann, H.

    1979-09-01

    A laboratory model of an X-ray detector with high spatial resolution was developed and constructed. It has no spectral resolution, but a local resolution of 20 μm which is about ten times as high as that of position-sensitive proportional counters and satisfies the requirements of the very best Wolter telescopes with regard to spatial resolution. The detector will be used for laboratory tests of the 80 cm Wolter telescope which is being developed for Spacelab flights. The theory of the wire grid detector and the physics of the photoelectric effect has been developed, and model calculations and numerical calculations have been carried out. (orig./WB) [de

  3. High Resolution Tracking Devices Based on Capillaries Filled with Liquid Scintillator

    CERN Multimedia

    Bonekamper, D; Vassiltchenko, V; Wolff, T

    2002-01-01

    %RD46 %title\\\\ \\\\The aim of the project is to develop high resolution tracking devices based on thin glass capillary arrays filled with liquid scintillator. This technique provides high hit densities and a position resolution better than 20 $\\mu$m. Further, their radiation hardness makes them superior to other types of tracking devices with comparable performance. Therefore, the technique is attractive for inner tracking in collider experiments, microvertex devices, or active targets for short-lived particle detection. High integration levels in the read-out based on the use of multi-pixel photon detectors and the possibility of optical multiplexing allow to reduce considerably the number of output channels, and, thus, the cost for the detector.\\\\ \\\\New optoelectronic devices have been developed and tested: the megapixel Electron Bombarded CCD (EBCCD), a high resolution image-detector having an outstanding capability of single photo-electron detection; the Vacuum Image Pipeline (VIP), a high-speed gateable pi...

  4. Modelling high-resolution electron microscopy based on core-loss spectroscopy

    International Nuclear Information System (INIS)

    Allen, L.J.; Findlay, S.D.; Oxley, M.P.; Witte, C.; Zaluzec, N.J.

    2006-01-01

    There are a number of factors affecting the formation of images based on core-loss spectroscopy in high-resolution electron microscopy. We demonstrate unambiguously the need to use a full nonlocal description of the effective core-loss interaction for experimental results obtained from high angular resolution electron channelling electron spectroscopy. The implications of this model are investigated for atomic resolution scanning transmission electron microscopy. Simulations are used to demonstrate that core-loss spectroscopy images formed using fine probes proposed for future microscopes can result in images that do not correspond visually with the structure that has led to their formation. In this context, we also examine the effect of varying detector geometries. The importance of the contribution to core-loss spectroscopy images by dechannelled or diffusely scattered electrons is reiterated here

  5. High resolution color imagery for orthomaps and remote sensing

    Energy Technology Data Exchange (ETDEWEB)

    Fricker, Peter [Leica Geosystems GIS and Mapping, LLC (Switzerland); Gallo, M. Guillermo [Leica Geosystems GIS and Mapping, LLC (United States)

    2005-07-01

    The ADS40 Airborne Digital Pushbroom Sensor is currently the only commercial sensor capable of acquiring color and false color strip images in the low decimeter range at the same high resolution as the black and white stereo images. This high resolution of 12,000 pixels across the entire swath and 100% forward overlap in the image strips result in high quality DSM's, True Ortho's and at the same time allow unbiased remote sensing applications due to color strip images unchanged by pan-sharpening. The paper gives details on how the pushbroom sensor achieves these seemingly difficult technical challenges. It describes how a variety of mapping applications benefit from this sensor, a sensor which acts as a satellite pushbroom sensor within the airborne environment. (author)

  6. High resolution solar observations from first principles to applications

    Science.gov (United States)

    Verdoni, Angelo P.

    2009-10-01

    The expression "high-resolution observations" in Solar Physics refers to the spatial, temporal and spectral domains in their entirety. High-resolution observations of solar fine structure are a necessity to answer many of the intriguing questions related to solar activity. However, a researcher building instruments for high-resolution observations has to cope with the fact that these three domains often have diametrically opposed boundary conditions. Many factors have to be considered in the design of a successful instrument. Modern post-focus instruments are more closely linked with the solar telescopes that they serve than in past. In principle, the quest for high-resolution observations already starts with the selection of the observatory site. The site survey of the Advanced Technology Solar Telescope (ATST) under the stewardship of the National Solar Observatory (NSO) has identified Big Bear Solar Observatory (BBSO) as one of the best sites for solar observations. In a first step, the seeing characteristics at BBSO based on the data collected for the ATST site survey are described. The analysis will aid in the scheduling of high-resolution observations at BBSO as well as provide useful information concerning the design and implementation of a thermal control system for the New Solar Telescope (NST). NST is an off-axis open-structure Gregorian-style telescope with a 1.6 m aperture. NST will be housed in a newly constructed 5/8-sphere ventilated dome. With optics exposed to the surrounding air, NST's open-structure design makes it particularly vulnerable to the effects of enclosure-related seeing. In an effort to mitigate these effects, the initial design of a thermal control system for the NST dome is presented. The goal is to remediate thermal related seeing effects present within the dome interior. The THermal Control System (THCS) is an essential component for the open-telescope design of NST to work. Following these tasks, a calibration routine for the

  7. Pneumonia: high-resolution CT findings in 114 patients

    Energy Technology Data Exchange (ETDEWEB)

    Reittner, Pia [Department of Radiology, Vancouver Hospital and Health Sciences Center, 855 W. 12th Ave., Vancouver, BC (Canada); Department of Radiology, Karl Franzens University and University Hospital Graz, Auenbruggerplatz 9, 8036 Graz (Austria); Ward, Suzanne; Heyneman, Laura; Mueller, Nestor L. [Department of Radiology, Vancouver Hospital and Health Sciences Center, 855 W. 12th Ave., Vancouver, BC (Canada); Johkoh, Takeshi [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0825 (Japan)

    2003-03-01

    The objective of the present study was to assess the high-resolution CT appearances of different types of pneumonia. The high-resolution CT scans obtained in 114 patients (58 immunocompetent, 59 immunocompromised) with bacterial, Mycoplasma pneumoniae, viral, fungal, and Pneumocystis carinii pneumonias were analyzed retrospectively by two independent observers for presence, pattern, and distribution of abnormalities. Areas of air-space consolidation were not detected in patients with viral pneumonia and were less frequently seen in patients with Pneumocystis carinii pneumonia (2 of 22 patients, 9%) than in bacterial (30 of 35, 85%), Mycoplasma pneumoniae (22 of 28, 79%), and fungal pneumonias (15 of 20, 75%; p<0.01). There was no significant difference in the prevalence or distribution of consolidation between bacterial, Mycoplasma pneumoniae, and fungal pneumonias. Extensive symmetric bilateral areas of ground-glass attenuation were present in 21 of 22 (95%) patients with Pneumocystis carinii pneumonia and were not seen in other pneumonias except in association with areas of consolidation and nodules. Centrilobular nodules were present less commonly in bacterial pneumonia (6 of 35 patients, 17%) than in Mycoplasma pneumoniae (24 of 28, 96%), viral (7 of 9, 78%), or fungal (12 of 20, 92%) pneumonia (p<0.01). Except for Pneumocystis carinii pneumonia and Mycoplasma pneumoniae pneumonia, which often have a characteristic appearance, high-resolution CT is of limited value in the differential diagnosis of the various types of infective pneumonia. (orig.)

  8. Pneumonia: high-resolution CT findings in 114 patients

    International Nuclear Information System (INIS)

    Reittner, Pia; Ward, Suzanne; Heyneman, Laura; Mueller, Nestor L.; Johkoh, Takeshi

    2003-01-01

    The objective of the present study was to assess the high-resolution CT appearances of different types of pneumonia. The high-resolution CT scans obtained in 114 patients (58 immunocompetent, 59 immunocompromised) with bacterial, Mycoplasma pneumoniae, viral, fungal, and Pneumocystis carinii pneumonias were analyzed retrospectively by two independent observers for presence, pattern, and distribution of abnormalities. Areas of air-space consolidation were not detected in patients with viral pneumonia and were less frequently seen in patients with Pneumocystis carinii pneumonia (2 of 22 patients, 9%) than in bacterial (30 of 35, 85%), Mycoplasma pneumoniae (22 of 28, 79%), and fungal pneumonias (15 of 20, 75%; p<0.01). There was no significant difference in the prevalence or distribution of consolidation between bacterial, Mycoplasma pneumoniae, and fungal pneumonias. Extensive symmetric bilateral areas of ground-glass attenuation were present in 21 of 22 (95%) patients with Pneumocystis carinii pneumonia and were not seen in other pneumonias except in association with areas of consolidation and nodules. Centrilobular nodules were present less commonly in bacterial pneumonia (6 of 35 patients, 17%) than in Mycoplasma pneumoniae (24 of 28, 96%), viral (7 of 9, 78%), or fungal (12 of 20, 92%) pneumonia (p<0.01). Except for Pneumocystis carinii pneumonia and Mycoplasma pneumoniae pneumonia, which often have a characteristic appearance, high-resolution CT is of limited value in the differential diagnosis of the various types of infective pneumonia. (orig.)

  9. Topography improvements in MEMS DMs for high-contrast, high-resolution imaging, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will develop and demonstrate an innovative microfabrication process to substantially improve the surface quality achievable in high-resolution...

  10. Scene Classification Using High Spatial Resolution Multispectral Data

    National Research Council Canada - National Science Library

    Garner, Jamada

    2002-01-01

    ...), High-spatial resolution (8-meter), 4-color MSI data from IKONOS provide a new tool for scene classification, The utility of these data are studied for the purpose of classifying the Elkhorn Slough and surrounding wetlands in central...

  11. Preliminary report on the development of a high resolution PET camera using semiconductor detectors

    International Nuclear Information System (INIS)

    Kikuchi, Yohei; Ishii, Keizo; Yamazaki, Hiromichi; Matsuyama, Shigeo; Yamaguchi, Takashi; Yamamoto, Yusuke; Sato, Takemi; Aoki, Yasushi; Aoki, Kenichi

    2005-01-01

    We are developing a PET camera using small semiconductor detectors, whose resolution is equivalent to the physical limit of spatial resolution. First, a coincidence system of 16 Schottky CdTe detectors of 0.5 mm width obtained a resolution of <1 mm and it was confirmed that the Schottky CdTe detector is suitable for high resolution PET. Next, the performance of a pair of 32 channel CdTe arrays (1.2 mm width per channel) was investigated for the development of the prototype of high resolution PET. The time resolution between opposing detector pair was 13 ns (FWHM) when high voltage (700 V) was applied. The image of a 0.6 mm diameter point source was obtained in an experiment with opposing detector arrays using four channels, indicating that, a higher resolution can be achieved with the 32 channel CdTe array

  12. High resolution reservoir geological modelling using outcrop information

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Changmin; Lin Kexiang; Liu Huaibo [Jianghan Petroleum Institute, Hubei (China)] [and others

    1997-08-01

    This is China`s first case study of high resolution reservoir geological modelling using outcrop information. The key of the modelling process is to build a prototype model and using the model as a geological knowledge bank. Outcrop information used in geological modelling including seven aspects: (1) Determining the reservoir framework pattern by sedimentary depositional system and facies analysis; (2) Horizontal correlation based on the lower and higher stand duration of the paleo-lake level; (3) Determining the model`s direction based on the paleocurrent statistics; (4) Estimating the sandbody communication by photomosaic and profiles; (6) Estimating reservoir properties distribution within sandbody by lithofacies analysis; and (7) Building the reservoir model in sandbody scale by architectural element analysis and 3-D sampling. A high resolution reservoir geological model of Youshashan oil field has been built by using this method.

  13. Turbine component casting core with high resolution region

    Science.gov (United States)

    Kamel, Ahmed; Merrill, Gary B.

    2014-08-26

    A hollow turbine engine component with complex internal features can include a first region and a second, high resolution region. The first region can be defined by a first ceramic core piece formed by any conventional process, such as by injection molding or transfer molding. The second region can be defined by a second ceramic core piece formed separately by a method effective to produce high resolution features, such as tomo lithographic molding. The first core piece and the second core piece can be joined by interlocking engagement that once subjected to an intermediate thermal heat treatment process thermally deform to form a three dimensional interlocking joint between the first and second core pieces by allowing thermal creep to irreversibly interlock the first and second core pieces together such that the joint becomes physically locked together providing joint stability through thermal processing.

  14. High-resolution neutron-diffraction measurements to 8 kbar

    Science.gov (United States)

    Bull, C. L.; Fortes, A. D.; Ridley, C. J.; Wood, I. G.; Dobson, D. P.; Funnell, N. P.; Gibbs, A. S.; Goodway, C. M.; Sadykov, R.; Knight, K. S.

    2017-10-01

    We describe the capability to measure high-resolution neutron powder diffraction data to a pressure of at least 8 kbar. We have used the HRPD instrument at the ISIS neutron source and a piston-cylinder design of pressure cell machined from a null-scattering titanium zirconium alloy. Data were collected under hydrostatic conditions from an elpasolite perovskite La?NiMnO?; by virtue of a thinner cell wall on the incident-beam side of the cell, it was possible to obtain data in the instrument's highest resolution back-scattering detector banks up to a maximum pressure of 8.5 kbar.

  15. Kinetic Energy from Supernova Feedback in High-resolution Galaxy Simulations

    Science.gov (United States)

    Simpson, Christine M.; Bryan, Greg L.; Hummels, Cameron; Ostriker, Jeremiah P.

    2015-08-01

    We describe a new method for adding a prescribed amount of kinetic energy to simulated gas modeled on a cartesian grid by directly altering grid cells’ mass and velocity in a distributed fashion. The method is explored in the context of supernova (SN) feedback in high-resolution (˜10 pc) hydrodynamic simulations of galaxy formation. Resolution dependence is a primary consideration in our application of the method, and simulations of isolated explosions (performed at different resolutions) motivate a resolution-dependent scaling for the injected fraction of kinetic energy that we apply in cosmological simulations of a 109 M⊙ dwarf halo. We find that in high-density media (≳50 cm-3) with coarse resolution (≳4 pc per cell), results are sensitive to the initial kinetic energy fraction due to early and rapid cooling. In our galaxy simulations, the deposition of small amounts of SN energy in kinetic form (as little as 1%) has a dramatic impact on the evolution of the system, resulting in an order-of-magnitude suppression of stellar mass. The overall behavior of the galaxy in the two highest resolution simulations we perform appears to converge. We discuss the resulting distribution of stellar metallicities, an observable sensitive to galactic wind properties, and find that while the new method demonstrates increased agreement with observed systems, significant discrepancies remain, likely due to simplistic assumptions that neglect contributions from SNe Ia and stellar winds.

  16. The spectrometer of the High-Resolution Multi position Thomson Scattering Diagnostic for TJ-II

    International Nuclear Information System (INIS)

    Herranz, J.; Barth, C. J.; Castejon, F.; Lopez-Sanchez, A.; Mirones, E.; Pastor, I.; Perez, D.; Rodriguez, C.

    2001-01-01

    Since 1998, a high-resolution multiposition thompson scattering system is in operation at the stellarator TJ-II, combining high accuracy and excellent spatial resolution. A description of the diagnostic spectrometer is presented. The main characteristics of the spectrometer that allow YJ-II Thomson scattering diagnostic to have high spatial and spectral resolution are described in this paper. (Author)

  17. Construction of a high resolution electron beam profile monitor

    International Nuclear Information System (INIS)

    Norem, J.; Dawson, J.; Haberichter, W.; Novak, W.; Reed, L.; Yang, X.F.

    1993-01-01

    Bremsstrahlung from an electron beam on a heavy target can be used to image the beam profile using collimators and slits. The limiting resolution using this system is determined by Fresnel diffraction, and is ∼ √(λd/2), where λ is the photon wavelength and d is determined by the linear dimensions of the system. For linear colliders this resolution could be a few nm. The highest resolution requires detectors which see only high energy, (small λ), photons, and this is accomplished by converting photons to pairs, and detecting Cherenkov light in a nearly forward angle with a CCD detector or streak camera. Tests are planned at the Argonne APS and SLAC FFTB

  18. Resolution of RNA using high-performance liquid chromatography

    NARCIS (Netherlands)

    Mclaughlin, L.W.; Bischoff, Rainer

    1987-01-01

    High-performance liquid chromatographic techniques can be very effective for the resolution and isolation of nucleic acids. The characteristic ionic (phosphodiesters) and hydrophobic (nucleobases) properties of RNAs can be exploited for their separation. In this respect anion-exchange and

  19. High-Resolution Remote Sensing Image Building Extraction Based on Markov Model

    Science.gov (United States)

    Zhao, W.; Yan, L.; Chang, Y.; Gong, L.

    2018-04-01

    With the increase of resolution, remote sensing images have the characteristics of increased information load, increased noise, more complex feature geometry and texture information, which makes the extraction of building information more difficult. To solve this problem, this paper designs a high resolution remote sensing image building extraction method based on Markov model. This method introduces Contourlet domain map clustering and Markov model, captures and enhances the contour and texture information of high-resolution remote sensing image features in multiple directions, and further designs the spectral feature index that can characterize "pseudo-buildings" in the building area. Through the multi-scale segmentation and extraction of image features, the fine extraction from the building area to the building is realized. Experiments show that this method can restrain the noise of high-resolution remote sensing images, reduce the interference of non-target ground texture information, and remove the shadow, vegetation and other pseudo-building information, compared with the traditional pixel-level image information extraction, better performance in building extraction precision, accuracy and completeness.

  20. MR-Venography Using High Resolution True-FISP

    Energy Technology Data Exchange (ETDEWEB)

    Spuentrup, E. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Beth Israel Deaconess Medical Center, Boston, MA (United States). Dept. of Medicine; Harvard Medical School, Boston, MA (United States); Buecker, A.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Stuber, M. [Beth Israel Deaconess Medical Center, Boston, MA (United States). Dept. of Medicine; Harvard Medical School, Boston, MA (United States); Philips Med. Syst., Best (Netherlands)

    2001-08-01

    A new fast MR-venography approach using a high resolution True-FISP imaging sequence was investigated in 20 patients suffering from 23 deep vein thromboses. Diagnosis was proven by X-ray venography, CT or ultrasound examination. The presented technique allowed for clear thrombus visualization with a high contrast to the surrounding blood pool even in calf veins. Acquisition time was less than 10 minutes for imaging the pelvis and the legs. No contrast media was needed. The presented high resolution True-FISP MR-veography is a promising non-invasive, fast MR-venography approach for detection of deep venous thrombosis. (orig.) [German] Eine neue schnelle, oertlich hochaufgeloeste MR-Phlebographietechnik mit einer axialen True-FISP Bildgebungssequenz wurde an 20 Patienten mit 23 nach-gewiesenen tiefen Beinvenenthrombosen untersucht. Die Befunde wurden mit einer konventionellen Roentgenphlebographie, einer CT oder einer Sonographie gesichert. Die vorgestellte Technik erlaubte in allen Faellen eine Thrombusdarstellung mit hohem Kontrast zum umgebenden venoesen Blut, wobei aufgrund der hohen Ortsaufloesung auch die Unterschenkelvenen beurteilt werden konnten. Die Datenaufnahmezeit zur Untersuchung des Beckens und der Beine betrug weniger als 10 Minuten. Kontrastmittel wurde nicht benoetigt. Die vorgestellte MR-Phlebographietechnik unter Verwendung einer oertlich hochauf-geloesten True-FISP Sequenz ist eine neue, vielversprechende, nicht-invasive Technik zur Diagnostik der tiefen Bein- und Beckenvenenthrombose. (orig.)