WorldWideScience

Sample records for high resolution myocardial

  1. Myocardial Infarction Area Quantification using High-Resolution SPECT Images in Rats

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Luciano Fonseca Lemos de [Divisão de Cardiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Mejia, Jorge [Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto, SP (Brazil); Carvalho, Eduardo Elias Vieira de; Lataro, Renata Maria; Frassetto, Sarita Nasbine [Divisão de Cardiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Fazan, Rubens Jr.; Salgado, Hélio Cesar [Departamento de Fisiologia, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Galvis-Alonso, Orfa Yineth [Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto, SP (Brazil); Simões, Marcus Vinícius, E-mail: msimoes@fmrp.usp.br [Divisão de Cardiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil)

    2013-07-15

    Imaging techniques enable in vivo sequential assessment of the morphology and function of animal organs in experimental models. We developed a device for high-resolution single photon emission computed tomography (SPECT) imaging based on an adapted pinhole collimator. To determine the accuracy of this system for quantification of myocardial infarct area in rats. Thirteen male Wistar rats (250 g) underwent experimental myocardial infarction by occlusion of the left coronary artery. After 4 weeks, SPECT images were acquired 1.5 hours after intravenous injection of 555 MBq of 99mTc-Sestamibi. The tomographic reconstruction was performed by using specially developed software based on the Maximum Likelihood algorithm. The analysis of the data included the correlation between the area of perfusion defects detected by scintigraphy and extent of myocardial fibrosis assessed by histology. The images showed a high target organ/background ratio with adequate visualization of the left ventricular walls and cavity. All animals presenting infarction areas were correctly identified by the perfusion images. There was no difference of the infarct area as measured by SPECT (21.1 ± 21.2%) and by histology (21.7 ± 22.0%; p=0.45). There was a strong correlation between individual values of the area of infarction measured by these two methods. The developed system presented adequate spatial resolution and high accuracy for the detection and quantification of myocardial infarction areas, consisting in a low cost and versatile option for high-resolution SPECT imaging of small rodents.

  2. Evaluation of general-purpose collimators against high-resolution collimators with resolution recovery with a view to reducing radiation dose in myocardial perfusion SPECT: A preliminary phantom study.

    Science.gov (United States)

    Armstrong, Ian S; Saint, Kimberley J; Tonge, Christine M; Arumugam, Parthiban

    2017-04-01

    There is a growing focus on reducing radiation dose to patients undergoing myocardial perfusion imaging. This preliminary phantom study aims to evaluate the use of general-purpose collimators with resolution recovery (RR) to allow a reduction in patient radiation dose. Images of a cardiac torso phantom with inferior and anterior wall defects were acquired on a GE Infinia and Siemens Symbia T6 using both high-resolution and general-purpose collimators. Imaging time, a surrogate for administered activity, was reduced between 35% and 40% with general-purpose collimators to match the counts acquired with high-resolution collimators. Images were reconstructed with RR with and without attenuation correction. Two pixel sizes were also investigated. Defect contrast was measured. Defect contrast on general-purpose images was superior or comparable to the high-resolution collimators on both systems despite the reduced imaging time. Infinia general-purpose images required a smaller pixel size to be used to maintain defect contrast, while Symbia T6 general-purpose images did not require a change in pixel size to that used for standard myocardial perfusion SPECT. This study suggests that general-purpose collimators with RR offer a potential for substantial dose reductions while providing similar or better image quality to images acquired using high-resolution collimators.

  3. Impact of metabolic syndrome on ST segment resolution after thrombolytic therapy for acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Ayşe Saatçı Yaşar

    2010-09-01

    Full Text Available Objectives: It has been shown that metabolic syndrome is associated with poor short-term outcome and poor long-term survival in patients with acute myocardial infarction. We aimed to investigate the effect of metabolic syndrome on ST segment resolution in patients received thrombolytic therapy for acute myocardial infarction.Materials and methods: We retrospectively analyzed 161 patients, who were admitted to our clinics with acute ST-elevated-myocardial infarction and received thrombolytic therapy within 12 hours of chest pain. Metabolic syndrome was diagnosed according to National Cholesterol Education Program Adult Treatment Panel III criteria. Resolution of ST segment elevation was assessed on the baseline and 90-minute electrocardiograms. ST segment resolution ≥70% was defined as complete resolution.Results: Metabolic syndrome was found in 56.5% of patients. The proportion of patients with metabolic syndrome who achieved complete ST segment resolution after thrombolysis was significantly lower than that of patients without metabolic syndrome (32.9% versus 58.6%, p=0.001. On multivariate analysis metabolic syndrome was the only independent predictor of ST segment resolution (p=0.01, Odds ratio=2.543, %95 CI:1.248-5.179Conclusion: The patients with metabolic syndrome had lower rates of complete ST segment resolution after thrombolytic therapy for acute myocardial infarction. This finding may contribute to the higher morbidity and mortality of patients with metabolic syndrome.

  4. Appearance of microvascular obstruction on high resolution first-pass perfusion, early and late gadolinium enhancement CMR in patients with acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Redwood Simon

    2009-08-01

    Full Text Available Abstract Background The presence and extent of microvascular obstruction (MO after acute myocardial infarction can be measured by first-pass gadolinium-enhanced perfusion cardiovascular magnetic resonance (CMR or after gadolinium injection with early or late enhancement (EGE/LGE imaging. The volume of MO measured by these three methods may differ because contrast agent diffusion into the MO reduces its apparent extent over time. Theoretically, first-pass perfusion CMR should be the most accurate method to measure MO, but this technique has been limited by lower spatial resolution than EGE and LGE as well as incomplete cardiac coverage. These limitations of perfusion CMR can be overcome using spatio-temporal undersampling methods. The purpose of this study was to compare the extent of MO by high resolution first-pass k-t SENSE accelerated perfusion, EGE and LGE. Methods 34 patients with acute ST elevation myocardial infarction, treated successfully with primary percutaneous coronary intervention (PPCI, underwent CMR within 72 hours of admission. k-t SENSE accelerated first-pass perfusion MR (7 fold acceleration, spatial resolution 1.5 mm × 1.5 mm × 10 mm, 8 slices acquired over 2 RR intervals, 0.1 mmol/kg Gd-DTPA, EGE (1–4 minutes after injection with a fixed TI of 440 ms and LGE images (10–12 minutes after injection, TI determined by a Look-Locker scout were acquired. MO volume was determined for each technique by manual planimetry and summation of discs methodology. Results k-t SENSE first-pass perfusion detected more cases of MO than EGE and LGE (22 vs. 20 vs. 14, respectively. The extent of MO imaged by first-pass perfusion (median mass 4.7 g, IQR 6.7 was greater than by EGE (median mass 2.3 g, IQR 7.1, p = 0.002 and LGE (median mass 0.2 g, IQR 2.4, p = 0.0003. The correlation coefficient between MO mass measured by first-pass perfusion and EGE was 0.91 (p Conclusion The extent of MO following acute myocardial infarction appears larger on

  5. The end of the unique myocardial band

    DEFF Research Database (Denmark)

    MacIver, David H; Partridge, John B; Agger, Peter

    2018-01-01

    Two of the leading concepts of mural ventricular architecture are the unique myocardial band and the myocardial mesh model. We have described, in an accompanying article published in this journal, how the anatomical, histological and high-resolution computed tomographic studies strongly favour th...

  6. Compressed sensing cine imaging with high spatial or high temporal resolution for analysis of left ventricular function.

    Science.gov (United States)

    Goebel, Juliane; Nensa, Felix; Schemuth, Haemi P; Maderwald, Stefan; Gratz, Marcel; Quick, Harald H; Schlosser, Thomas; Nassenstein, Kai

    2016-08-01

    To assess two compressed sensing cine magnetic resonance imaging (MRI) sequences with high spatial or high temporal resolution in comparison to a reference steady-state free precession cine (SSFP) sequence for reliable quantification of left ventricular (LV) volumes. LV short axis stacks of two compressed sensing breath-hold cine sequences with high spatial resolution (SPARSE-SENSE HS: temporal resolution: 40 msec, in-plane resolution: 1.0 × 1.0 mm(2) ) and high temporal resolution (SPARSE-SENSE HT: temporal resolution: 11 msec, in-plane resolution: 1.7 × 1.7 mm(2) ) and of a reference cine SSFP sequence (standard SSFP: temporal resolution: 40 msec, in-plane resolution: 1.7 × 1.7 mm(2) ) were acquired in 16 healthy volunteers on a 1.5T MR system. LV parameters were analyzed semiautomatically twice by one reader and once by a second reader. The volumetric agreement between sequences was analyzed using paired t-test, Bland-Altman plots, and Passing-Bablock regression. Small differences were observed between standard SSFP and SPARSE-SENSE HS for stroke volume (SV; -7 ± 11 ml; P = 0.024), ejection fraction (EF; -2 ± 3%; P = 0.019), and myocardial mass (9 ± 9 g; P = 0.001), but not for end-diastolic volume (EDV; P = 0.079) and end-systolic volume (ESV; P = 0.266). No significant differences were observed between standard SSFP and SPARSE-SENSE HT regarding EDV (P = 0.956), SV (P = 0.088), and EF (P = 0.103), but for ESV (3 ± 5 ml; P = 0.039) and myocardial mass (8 ± 10 ml; P = 0.007). Bland-Altman analysis showed good agreement between the sequences (maximum bias ≤ -8%). Two compressed sensing cine sequences, one with high spatial resolution and one with high temporal resolution, showed good agreement with standard SSFP for LV volume assessment. J. Magn. Reson. Imaging 2016;44:366-374. © 2016 Wiley Periodicals, Inc.

  7. Comparison of quantitative myocardial perfusion imaging CT to fluorescent microsphere-based flow from high-resolution cryo-images

    Science.gov (United States)

    Eck, Brendan L.; Fahmi, Rachid; Levi, Jacob; Fares, Anas; Wu, Hao; Li, Yuemeng; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2016-03-01

    Myocardial perfusion imaging using CT (MPI-CT) has the potential to provide quantitative measures of myocardial blood flow (MBF) which can aid the diagnosis of coronary artery disease. We evaluated the quantitative accuracy of MPI-CT in a porcine model of balloon-induced LAD coronary artery ischemia guided by fractional flow reserve (FFR). We quantified MBF at baseline (FFR=1.0) and under moderate ischemia (FFR=0.7) using MPI-CT and compared to fluorescent microsphere-based MBF from high-resolution cryo-images. Dynamic, contrast-enhanced CT images were obtained using a spectral detector CT (Philips Healthcare). Projection-based mono-energetic images were reconstructed and processed to obtain MBF. Three MBF quantification approaches were evaluated: singular value decomposition (SVD) with fixed Tikhonov regularization (ThSVD), SVD with regularization determined by the L-Curve criterion (LSVD), and Johnson-Wilson parameter estimation (JW). The three approaches over-estimated MBF compared to cryo-images. JW produced the most accurate MBF, with average error 33.3+/-19.2mL/min/100g, whereas LSVD and ThSVD had greater over-estimation, 59.5+/-28.3mL/min/100g and 78.3+/-25.6 mL/min/100g, respectively. Relative blood flow as assessed by a flow ratio of LAD-to-remote myocardium was strongly correlated between JW and cryo-imaging, with R2=0.97, compared to R2=0.88 and 0.78 for LSVD and ThSVD, respectively. We assessed tissue impulse response functions (IRFs) from each approach for sources of error. While JW was constrained to physiologic solutions, both LSVD and ThSVD produced IRFs with non-physiologic properties due to noise. The L-curve provided noise-adaptive regularization but did not eliminate non-physiologic IRF properties or optimize for MBF accuracy. These findings suggest that model-based MPI-CT approaches may be more appropriate for quantitative MBF estimation and that cryo-imaging can support the development of MPI-CT by providing spatial distributions of MBF.

  8. Measurement of myocardial perfusion using magnetic resonance

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Jensen, L.T.; Larsson, H.B.

    2008-01-01

    Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper reviews...... myocardial perfusion imaging with MR contrast agents: methods, validation and experiences from clinical studies. Unresolved issues still restrict the use of these techniques to research although clinical applications are within reach Udgivelsesdato: 2008/12/8...

  9. Proton chemical shift imaging after myocardial infarction

    International Nuclear Information System (INIS)

    Bouchard, A.; Doyle, M.; Pohost, G.M.

    1989-01-01

    The present study was undertaken to test whether chemical shift imaging could detect spatially the lipids known to accumulate in myocardium after an ischemic insult. Seven dogs underwent a 24-hour coronary artery occlusion. Hearts were removed and imaged ex vivo by the Dixon method (1.5 T), and myocardial samples were obtained for high-resolution H-1 spectroscopy. Lipid images revealed regions of increased signal intensity in the periphery f the myocardial infarction. The zones of high lipid signal corresponded to zones with elevated mobile lipids as detected by H-1 spectroscopy

  10. Myocardial perfusion MRI with sliding-window conjugate-gradient HYPR.

    Science.gov (United States)

    Ge, Lan; Kino, Aya; Griswold, Mark; Mistretta, Charles; Carr, James C; Li, Debiao

    2009-10-01

    First-pass perfusion MRI is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. In this study we investigated the feasibility of using a method that combines sliding window and CG-HYPR methods (SW-CG-HYPR) to reduce the acquisition window for each slice while maintaining the temporal resolution of one frame per heartbeat in myocardial perfusion MRI. This method allows an increased number of slices, reduced motion artifacts, and preserves the relatively high SNR and spatial resolution of the "composite images." Results from eight volunteers demonstrate the feasibility of SW-CG-HYPR for accelerated myocardial perfusion imaging with accurate signal intensity changes of left ventricle blood pool and myocardium. Using this method the acquisition time per cardiac cycle was reduced by a factor of 4 and the number of slices was increased from 3 to 8 as compared to the conventional technique. The SNR of the myocardium at peak enhancement with SW-CG-HYPR (13.83 +/- 2.60) was significantly higher (P < 0.05) than the conventional turbo-FLASH protocol (8.40 +/- 1.62). Also, the spatial resolution of the myocardial perfection images was significantly improved. SW-CG-HYPR is a promising technique for myocardial perfusion MRI. (c) 2009 Wiley-Liss, Inc.

  11. The end of the unique myocardial band: Part II. Clinical and functional considerations

    NARCIS (Netherlands)

    MacIver, David H.; Partridge, John B.; Agger, Peter; Stephenson, Robert S.; Boukens, Bastiaan J. D.; Omann, Camilla; Jarvis, Jonathan C.; Zhang, Henggui

    2018-01-01

    Two of the leading concepts of mural ventricular architecture are the unique myocardial band and the myocardial mesh model. We have described, in an accompanying article published in this journal, how the anatomical, histological and high-resolution computed tomographic studies strongly favour the

  12. Direct comparison of high-temporal-resolution CINE MRI with Doppler ultrasound for assessment of diastolic dysfunction in mice.

    Science.gov (United States)

    Roberts, Thomas A; Price, Anthony N; Jackson, Laurence H; Taylor, Valerie; David, Anna L; Lythgoe, Mark F; Stuckey, Daniel J

    2017-10-01

    Diastolic dysfunction is a sensitive early indicator of heart failure and can provide additional data to conventional measures of systolic function. Transmitral Doppler ultrasound, which measures the one-dimensional flow of blood through the mitral valve, is currently the preferred method for the measurement of diastolic function, but the measurement of the left ventricular volume changes using high-temporal-resolution cinematic magnetic resonance imaging (CINE MRI) is an alternative approach which is emerging as a potentially more robust and user-independent technique. Here, we investigated the performance of high-temporal-resolution CINE MRI and compared it with ultrasound for the detection of diastolic dysfunction in a mouse model of myocardial infarction. An in-house, high-temporal-resolution, retrospectively gated CINE sequence was developed with a temporal resolution of 1 ms. Diastolic function in mice was assessed using a custom-made, open-source reconstruction package. Early (E) and late (A) left ventricular filling phases were easily identifiable, and these measurements were compared directly with high-frequency, pulsed-wave, Doppler ultrasound measurements of mitral valve inflow. A repeatability study established that high-temporal-resolution CINE MRI and Doppler ultrasound showed comparable accuracy when measuring E/A in normal control mice. However, when applied in a mouse model of myocardial infarction, high-temporal-resolution CINE MRI indicated diastolic heart failure (E/A = 0.94 ± 0.11), whereas ultrasound falsely detected normal cardiac function (E/A = 1.21 ± 0.11). The addition of high-temporal-resolution CINE MRI to preclinical imaging studies enhances the library of sequences available to cardiac researchers and potentially identifies diastolic heart failure early in disease progression. © 2017 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

  13. High-resolution MRI for the quantitative evaluation of subendocardial and subepicardial perfusion under pharmalogical stress and at rest

    International Nuclear Information System (INIS)

    Ritter, C.O.; Savio, K. del; Brackertz, A.; Beer, M.; Hahn, D.; Koestler, H.

    2007-01-01

    Purpose: MR stress perfusion imaging of the heart allows the quantification of myocardial perfusion and the evaluation of myocardial perfusion reserve (MPR) and the ratio of subendocardial to subepicardial perfusion at rest and under adenosine stress. The aim of this study was to evaluate a high-resolution GRAPPA sequence for quantitative MR first pass perfusion imaging in healthy volunteers. Materials and Methods: First pass stress and rest perfusion studies were performed on 10 healthy volunteers using a 1.5 T MR scanner with a multislice SR-TrueFISP first pass perfusion sequence with a GRAPPA algorithm (acceleration factor 3) in prebolus technique and an image resolution of 1.8 x 1.8 mm. For the comparison group, we examined 12 different healthy volunteers with a standard first pass perfusion SR-TrueFISP sequence using a resolution of 2.7 x 3.3 mm. Myocardial contours were manually delineated followed by an automatic division of the myocardium into two rings with an equal thickness for the subendo- and subepicardial layer. Eight sectors per slice were evaluated using contamination and baseline correction. Results: Using the GRAPPA sequence, the ratio of subendo- to subepimyocardial perfusion was 1.18 ± 0.32 for the examination at rest. Under pharmacologically induced stress, the ratio was 1.08 ± 0.27. For the standard sequence the ratio was 1.15 ± 0.28 at rest and 1.11 ± 0.33 under stress. For the high resolution sequence higher mean values for the subendo- to subepimyocardial ratio were obtained with comparable standard deviations. The difference between the sequences was not significant. Conclusion: The evaluation of subendomyocardial and subepimyocardial perfusion is feasible with a high-resolution first pass perfusion sequence. The use of a higher resolution to avoid systematic error leads to increased image noise. However, no relevant reduction in the quantitative perfusion values under stress and at rest was able to be depicted. (orig.)

  14. Myocardial perfusion magnetic resonance imaging using sliding-window conjugate-gradient highly constrained back-projection reconstruction for detection of coronary artery disease.

    Science.gov (United States)

    Ma, Heng; Yang, Jun; Liu, Jing; Ge, Lan; An, Jing; Tang, Qing; Li, Han; Zhang, Yu; Chen, David; Wang, Yong; Liu, Jiabin; Liang, Zhigang; Lin, Kai; Jin, Lixin; Bi, Xiaoming; Li, Kuncheng; Li, Debiao

    2012-04-15

    Myocardial perfusion magnetic resonance imaging (MRI) with sliding-window conjugate-gradient highly constrained back-projection reconstruction (SW-CG-HYPR) allows whole left ventricular coverage, improved temporal and spatial resolution and signal/noise ratio, and reduced cardiac motion-related image artifacts. The accuracy of this technique for detecting coronary artery disease (CAD) has not been determined in a large number of patients. We prospectively evaluated the diagnostic performance of myocardial perfusion MRI with SW-CG-HYPR in patients with suspected CAD. A total of 50 consecutive patients who were scheduled for coronary angiography with suspected CAD underwent myocardial perfusion MRI with SW-CG-HYPR at 3.0 T. The perfusion defects were interpreted qualitatively by 2 blinded observers and were correlated with x-ray angiographic stenoses ≥50%. The prevalence of CAD was 56%. In the per-patient analysis, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of SW-CG-HYPR was 96% (95% confidence interval 82% to 100%), 82% (95% confidence interval 60% to 95%), 87% (95% confidence interval 70% to 96%), 95% (95% confidence interval 74% to100%), and 90% (95% confidence interval 82% to 98%), respectively. In the per-vessel analysis, the corresponding values were 98% (95% confidence interval 91% to 100%), 89% (95% confidence interval 80% to 94%), 86% (95% confidence interval 76% to 93%), 99% (95% confidence interval 93% to 100%), and 93% (95% confidence interval 89% to 97%), respectively. In conclusion, myocardial perfusion MRI using SW-CG-HYPR allows whole left ventricular coverage and high resolution and has high diagnostic accuracy in patients with suspected CAD. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. A novel high resolution, high sensitivity SPECT detector for molecular imaging of cardiovascular diseases

    Science.gov (United States)

    Cusanno, F.; Argentieri, A.; Baiocchi, M.; Colilli, S.; Cisbani, E.; De Vincentis, G.; Fratoni, R.; Garibaldi, F.; Giuliani, F.; Gricia, M.; Lucentini, M.; Magliozzi, M. L.; Majewski, S.; Marano, G.; Musico, P.; Musumeci, M.; Santavenere, F.; Torrioli, S.; Tsui, B. M. W.; Vitelli, L.; Wang, Y.

    2010-05-01

    Cardiovascular diseases are the most common cause of death in western countries. Understanding the rupture of vulnerable atherosclerotic plaques and monitoring the effect of innovative therapies of heart failure is of fundamental importance. A flexible, high resolution, high sensitivity detector system for molecular imaging with radionuclides on small animal models has been designed for this aim. A prototype has been built using tungsten pinhole and LaBr3(Ce) scintillator coupled to Hamamatsu Flat Panel PMTs. Compact individual-channel readout has been designed, built and tested. Measurements with phantoms as well as pilot studies on mice have been performed, the results show that the myocardial perfusion in mice can be determined with sufficient precision. The detector will be improved replacing the Hamamatsu Flat Panel with Silicon Photomultipliers (SiPMs) to allow integration of the system with MRI scanners. Application of LaBr3(Ce) scintillator coupled to photosensor with high photon detection efficiency and excellent energy resolution will allow dual-label imaging to monitor simultaneously the cardiac perfusion and the molecular targets under investigation during the heart therapy.

  16. Feasibility of high-resolution quantitative perfusion analysis in patients with heart failure.

    Science.gov (United States)

    Sammut, Eva; Zarinabad, Niloufar; Wesolowski, Roman; Morton, Geraint; Chen, Zhong; Sohal, Manav; Carr-White, Gerry; Razavi, Reza; Chiribiri, Amedeo

    2015-02-12

    Cardiac magnetic resonance (CMR) is playing an expanding role in the assessment of patients with heart failure (HF). The assessment of myocardial perfusion status in HF can be challenging due to left ventricular (LV) remodelling and wall thinning, coexistent scar and respiratory artefacts. The aim of this study was to assess the feasibility of quantitative CMR myocardial perfusion analysis in patients with HF. A group of 58 patients with heart failure (HF; left ventricular ejection fraction, LVEF ≤ 50%) and 33 patients with normal LVEF (LVEF >50%), referred for suspected coronary artery disease, were studied. All subjects underwent quantitative first-pass stress perfusion imaging using adenosine according to standard acquisition protocols. The feasibility of quantitative perfusion analysis was then assessed using high-resolution, 3 T kt perfusion and voxel-wise Fermi deconvolution. 30/58 (52%) subjects in the HF group had underlying ischaemic aetiology. Perfusion abnormalities were seen amongst patients with ischaemic HF and patients with normal LV function. No regional perfusion defect was observed in the non-ischaemic HF group. Good agreement was found between visual and quantitative analysis across all groups. Absolute stress perfusion rate, myocardial perfusion reserve (MPR) and endocardial-epicardial MPR ratio identified areas with abnormal perfusion in the ischaemic HF group (p = 0.02; p = 0.04; p = 0.02, respectively). In the Normal LV group, MPR and endocardial-epicardial MPR ratio were able to distinguish between normal and abnormal segments (p = 0.04; p = 0.02 respectively). No significant differences of absolute stress perfusion rate or MPR were observed comparing visually normal segments amongst groups. Our results demonstrate the feasibility of high-resolution voxel-wise perfusion assessment in patients with HF.

  17. Bivariable analysis of ventricular late potentials in high resolution ECG records

    International Nuclear Information System (INIS)

    Orosco, L; Laciar, E

    2007-01-01

    In this study the bivariable analysis for ventricular late potentials detection in high-resolution electrocardiographic records is proposed. The standard time-domain analysis and the application of the time-frequency technique to high-resolution ECG records are briefly described as well as their corresponding results. In the proposed technique the time-domain parameter, QRSD and the most significant time-frequency index, EN QRS are used like variables. A bivariable index is defined, that combines the previous parameters. The propose technique allows evaluating the risk of ventricular tachycardia in post-myocardial infarct patients. The results show that the used bivariable index allows discriminating between the patient's population with ventricular tachycardia and the subjects of the control group. Also, it was found that the bivariable technique obtains a good valuation as diagnostic test. It is concluded that comparatively, the valuation of the bivariable technique as diagnostic test is superior to that of the time-domain method and the time-frequency technique evaluated individually

  18. Cardiac MRI for myocardial ischemia.

    LENUS (Irish Health Repository)

    Daly, Caroline

    2013-01-01

    Proper assessment of the physiologic impact of coronary artery stenosis on the LV myocardium can affect patient prognosis and treatment decisions. Cardiac magnetic resonance imaging (CMR) assesses myocardial perfusion by imaging the myocardium during a first-pass transit of an intravenous gadolinium bolus, with spatial and temporal resolution substantially higher than nuclear myocardial perfusion imaging. Coupled with late gadolinium enhancement (LGE) imaging for infarction during the same imaging session, CMR with vasodilating stress perfusion imaging can qualitatively and quantitatively assess the myocardial extent of hypoperfusion from coronary stenosis independent of infarcted myocardium. This approach has been validated experimentally, and multiple clinical trials have established its diagnostic robustness when compared to stress single-photon emission computed tomography. In specialized centers, dobutamine stress CMR has been shown to have incremental diagnostic value above stress echocardiography due to its high imaging quality and ability to image the heart with no restriction of imaging window. This paper reviews the technical aspects, diagnostic utility, prognostic values, challenges to clinical adaptation, and future developments of stress CMR imaging.

  19. High fat diet-induced glucose intolerance impairs myocardial function, but not myocardial perfusion during hyperaemia: a pilot study

    Directory of Open Access Journals (Sweden)

    van den Brom Charissa E

    2012-06-01

    Full Text Available Abstract Background Glucose intolerance is a major health problem and is associated with increased risk of progression to type 2 diabetes mellitus and cardiovascular disease. However, whether glucose intolerance is related to impaired myocardial perfusion is not known. The purpose of the present study was to study the effect of diet-induced glucose intolerance on myocardial function and perfusion during baseline and pharmacological induced hyperaemia. Methods Male Wistar rats were randomly exposed to a high fat diet (HFD or control diet (CD (n = 8 per group. After 4 weeks, rats underwent an oral glucose tolerance test. Subsequently, rats underwent (contrast echocardiography to determine myocardial function and perfusion during baseline and dipyridamole-induced hyperaemia (20 mg/kg for 10 min. Results Four weeks of HFD feeding resulted in glucose intolerance compared to CD-feeding. Contractile function as represented by fractional shortening was not altered in HFD-fed rats compared to CD-fed rats under baseline conditions. However, dipyridamole increased fractional shortening in CD-fed rats, but not in HFD-fed rats. Basal myocardial perfusion, as measured by estimate of perfusion, was similar in CD- and HFD-fed rats, whereas dipyridamole increased estimate of perfusion in CD-fed rats, but not in HFD-fed rats. However, flow reserve was not different between CD- and HFD-fed rats. Conclusions Diet-induced glucose intolerance is associated with impaired myocardial function during conditions of hyperaemia, but myocardial perfusion is maintained. These findings may result in new insights into the effect of glucose intolerance on myocardial function and perfusion during hyperaemia.

  20. Impact of gender on infarct size, ST-segment resolution, myocardial blush and clinical outcomes after primary stenting for acute myocardial infarction: Substudy from the EMERALD trial.

    Science.gov (United States)

    Ng, Vivian G; Mori, Ken; Costa, Ricardo A; Kish, Mitra; Mehran, Roxana; Urata, Hidenori; Saku, Keijiro; Stone, Gregg W; Lansky, Alexandra J

    2016-03-15

    Women with AMI may have worse outcomes than men. However, it is unclear if this is related to differences in treatment, treatment effect or gender specific factors. We sought to determine whether primary percutaneous intervention (PCI) has a differential impact on infarct size, myocardial perfusion and ST segment resolution in men and women with acute myocardial infarction (AMI). A total of 501 AMI patients were prospectively enrolled in the EMERALD study and underwent PCI with or without distal protection. Post hoc gender subset analysis was performed. 501 patients (108 women, 393 men) with ST-segment elevation AMI presenting within 6h underwent primary (or rescue) PCI with stenting and a distal protection device. Women were older, had more hypertension, less prior AMI, smaller BSA, and smaller vessel size, but had similar rates of diabetes (30% versus 20.2%, p=0.87), LAD infarct, and time-to-reperfusion compared to men. Women more frequently had complete ST-resolution (>70%) at 30days (72.8% versus 59.8%, p=0.02), and smaller infarct size compared to males (12.2±19.6% versus 18.4±18.5%, p=0.006). At 6months, TLR (6.9% versus 5.2%) and MACE (11.4% versus 10.3%) were similar for women and men. Despite worse comorbidities, women with AMI treated with primary PCI with stenting showed similar early and midterm outcomes compared to men. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Effects of short-term high-fat, high-energy diet on hepatic and myocardial triglyceride content in healthy men

    NARCIS (Netherlands)

    van der Meer, Rutger W.; Hammer, Sebastiaan; Lamb, Hildo J.; Frölich, Marijke; Diamant, Michaela; Rijzewijk, Luuk J.; de Roos, Albert; Romijn, Johannes A.; Smit, Johannes W. A.

    2008-01-01

    An association has been suggested between elevated plasma nonesterified fatty acid (NEFA) levels, myocardial triglyceride (TG) accumulation, and myocardial function. Our objective was to investigate the effects of an elevation of plasma NEFA by a high-fat, high-energy (HFHE) diet on hepatic and

  2. Myocardial protection induced by fentanyl in pigs exposed to high-dose adrenaline.

    Science.gov (United States)

    da Luz, Vinicius Fernando; Otsuki, Denise Aya; Gonzalez, Maria Margarita Castro; Negri, Elnara Marcia; Caldini, Elia Garcia; Damaceno-Rodrigues, Nilsa Regina; Malbouisson, Luiz Marcelo Sá; Viana, Bruno Gonçalves; Vane, Matheus Fachini; Carmona, Maria Jose Carvalho

    2015-10-01

    The use of high doses of adrenaline is common in critical patients, especially during cardiac arrest. During these situations, myocardial dysfunction can be a result of multiple factors, including adrenaline use. In addition, opioids have been shown to have anti-arrhythmic and anti-ischemic mechanisms that may confer cardiac protection. This study aimed to evaluate the effects of fentanyl on myocardial function in pigs exposed to high-dose adrenaline. After institutional ethics committee approval, 26 pigs were randomly allocated to receive either 20 μg/kg fentanyl (n = 10; fentanyl group) administered 5 min before five doses of adrenaline (20 μg/kg), equivalent-volume saline (n = 10; saline group) using the same adrenaline dosing protocol, or neither fentanyl nor adrenaline (n = 6; sham group). The fentanyl group showed lower levels of troponin at the end of the sixth hour compared with the saline group (1.91 ± 1.47 vs 5.44 ± 5.35 ng/mL, P = 0.019). Transmission electron microscopy and immunohistochemistry also showed less myocardial injury in the fentanyl group. The conclusion was reached that fentanyl attenuates myocardial injury caused by high-dose adrenaline without blunting the hemodynamic effect of adrenaline. © 2015 Wiley Publishing Asia Pty Ltd.

  3. ST-segment resolution with bivalirudin versus heparin and routine glycoprotein IIb/IIIa inhibitors started in the ambulance in ST-segment elevation myocardial infarction patients transported for primary percutaneous coronary intervention: The EUROMAX ST-segment resolution substudy.

    Science.gov (United States)

    Van't Hof, Arnoud; Giannini, Francesco; Ten Berg, Jurrien; Tolsma, Rudolf; Clemmensen, Peter; Bernstein, Debra; Coste, Pierre; Goldstein, Patrick; Zeymer, Uwe; Hamm, Christian; Deliargyris, Efthymios; Steg, Philippe G

    2017-08-01

    Myocardial reperfusion after primary percutaneous coronary intervention (PCI) can be assessed by the extent of post-procedural ST-segment resolution. The European Ambulance Acute Coronary Syndrome Angiography (EUROMAX) trial compared pre-hospital bivalirudin and pre-hospital heparin or enoxaparin with or without GPIIb/IIIa inhibitors (GPIs) in primary PCI. This nested substudy was performed in centres routinely using pre-hospital GPI in order to compare the impact of randomized treatments on ST-resolution after primary PCI. Residual cumulative ST-segment deviation on the single one hour post-procedure electrocardiogram (ECG) was assessed by an independent core laboratory and was the primary endpoint. It was calculated that 762 evaluable patients were needed to show non-inferiority (85% power, alpha 2.5%) between randomized treatments. A total of 871 participated with electrocardiographic data available in 824 patients (95%). Residual ST-segment deviation one hour after PCI was 3.8±4.9 mm versus 3.9±5.2 mm for bivalirudin and heparin+GPI, respectively ( p=0.0019 for non-inferiority). Overall, there were no differences between randomized treatments in any measures of ST-segment resolution either before or after the index procedure. Pre-hospital treatment with bivalirudin is non-inferior to pre-hospital heparin + GPI with regard to residual ST-segment deviation or ST-segment resolution, reflecting comparable myocardial reperfusion with the two strategies.

  4. High-resolution X-ray television and high-resolution video recorders

    International Nuclear Information System (INIS)

    Haendle, J.; Horbaschek, H.; Alexandrescu, M.

    1977-01-01

    The improved transmission properties of the high-resolution X-ray television chain described here make it possible to transmit more information per television image. The resolution in the fluoroscopic image, which is visually determined, depends on the dose rate and the inertia of the television pick-up tube. This connection is discussed. In the last few years, video recorders have been increasingly used in X-ray diagnostics. The video recorder is a further quality-limiting element in X-ray television. The development of function patterns of high-resolution magnetic video recorders shows that this quality drop may be largely overcome. The influence of electrical band width and number of lines on the resolution in the X-ray television image stored is explained in more detail. (orig.) [de

  5. Mortality rate in type 2 myocardial infarction

    DEFF Research Database (Denmark)

    Saaby, Lotte; Poulsen, Tina Svenstrup; Diederichsen, Axel Cosmus Pyndt

    2014-01-01

    myocardial infarction, hypercholesterolemia, high p-creatinine, and diabetes mellitus. The multivariable-adjusted hazard ratio for type 2 myocardial infarction was 2.0 (95% confidence interval, 1.3-3.0). With shock as the only exception, mortality was independent of the triggering conditions leading to type....../119) in those with type 2 myocardial infarction and 26% (92/360) in those with type 1 myocardial infarction (P high age, prior myocardial infarction, type 2...... 2 myocardial infarction. CONCLUSIONS: Mortality in patients with type 2 myocardial infarction is high, reaching approximately 50% after 2 years. Further descriptive and survival studies are needed to improve the scientific evidence on which treatment of type 2 myocardial infarction is based....

  6. ANL high resolution injector

    International Nuclear Information System (INIS)

    Minehara, E.; Kutschera, W.; Hartog, P.D.; Billquist, P.

    1985-01-01

    The ANL (Argonne National Laboratory) high-resolution injector has been installed to obtain higher mass resolution and higher preacceleration, and to utilize effectively the full mass range of ATLAS (Argonne Tandem Linac Accelerator System). Preliminary results of the first beam test are reported briefly. The design and performance, in particular a high-mass-resolution magnet with aberration compensation, are discussed. 7 refs., 5 figs., 2 tabs

  7. Quantitative characterization of myocardial infarction by cardiovascular magnetic resonance predicts future cardiovascular events in patients with ischemic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Pauly John M

    2008-04-01

    Full Text Available Abstract Background Cardiovascular magnetic resonance (CMR can provide quantitative data of the myocardial tissue utilizing high spatial and temporal resolution along with exquisite tissue contrast. Previous studies have correlated myocardial scar tissue with the occurrence of ventricular arrhythmia. This study was conducted to evaluate whether characterization of myocardial infarction by CMR can predict cardiovascular events in patients with ischemic cardiomyopathy (ICM. Results We consecutively studied 86 patients with ICM (LVEF Conclusion Quantification of the scar volume and scar percentage by CMR is superior to LVEDV, LVESV, and LVEF in prognosticating the future likelihood of the development of cardiovascular events in patients with ICM.

  8. Myocardial perfusion magnetic resonance imaging using sliding-window conjugate-gradient HYPR methods in canine with stenotic coronary arteries.

    Science.gov (United States)

    Ge, Lan; Kino, Aya; Lee, Daniel; Dharmakumar, Rohan; Carr, James C; Li, Debiao

    2010-01-01

    First-pass perfusion magnetic resonance imaging (MRI) is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. A combination of sliding window and conjugate-gradient HighlY constrained back-PRojection reconstruction (SW-CG-HYPR) method has been proposed in healthy volunteer studies to reduce the acquisition window for each slice while maintaining the temporal resolution of 1 frame per heartbeat in myocardial perfusion MRI. This method allows for improved spatial coverage, resolution, and SNR. In this study, we use a controlled animal model to test whether the myocardial territory supplied by a stenotic coronary artery can be detected accurately by SW-CG-HYPR perfusion method under pharmacological stress. Results from 6 mongrel dogs (15-25 kg) studies demonstrate the feasibility of SW-CG-HYPR to detect regional perfusion defects. Using this method, the acquisition time per cardiac cycle was reduced by a factor of 4, and the spatial coverage was increased from 2 to 3 slices to 6 slices as compared with the conventional techniques including both turbo-Fast Low Angle Short (FLASH) and echoplanar imaging (EPI). The SNR of the healthy myocardium at peak enhancement with SW-CG-HYPR (12.68 ± 2.46) is significantly higher (P < 0.01) than the turbo-FLASH (8.65 ± 1.93) and EPI (5.48 ± 1.24). The spatial resolution of SW-CG-HYPR images is 1.2 × 1.2 × 8.0 mm, which is better than the turbo-FLASH (1.8 × 1.8 × 8.0 mm) and EPI (2.0 × 1.8 × 8.0 mm). Sliding-window CG-HYPR is a promising technique for myocardial perfusion MRI. This technique provides higher image quality with respect to significantly improved SNR and spatial resolution of the myocardial perfusion images, which might improve myocardial perfusion imaging in a clinical setting.

  9. ST-segment resolution with bivalirudin versus heparin and routine glycoprotein IIb/IIIa inhibitors started in the ambulance in ST-segment elevation myocardial infarction patients transported for primary percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Van't Hof, Arnoud; Giannini, Francesco; Ten Berg, Jurrien

    2017-01-01

    BACKGROUND: Myocardial reperfusion after primary percutaneous coronary intervention (PCI) can be assessed by the extent of post-procedural ST-segment resolution. The European Ambulance Acute Coronary Syndrome Angiography (EUROMAX) trial compared pre-hospital bivalirudin and pre-hospital heparin o...

  10. High-dose fasudil preserves postconditioning against myocardial infarction under hyperglycemia in rats: role of mitochondrial KATP channels

    Directory of Open Access Journals (Sweden)

    Ichinomiya Taiga

    2012-03-01

    Full Text Available Abstract Background The current study was carried out to determine whether fasudil hydrochloride (fasudil, a Rho-kinase inhibitor, has myocardial postconditioning (PostC activity under hyperglycemia as well as normoglycemia, and if so, whether the effects could be mediated by mitochondrial ATP-sensitive potassium (m-KATP channels. Methods Male Sprague-Dawley rats were anesthetized with sodium pentobarbital. After opening the chest, all rats underwent 30-min coronary artery occlusion followed by 2-h reperfusion. The rats received low-dose (0.15 mg/kg or high-dose (0.5 mg/kg fasudil or diazoxide, an m-KATP channel opener, at 10 mg/kg, just before reperfusion under normoglycemic or hyperglycemic conditions. In another group, rats received 5-hydroxydecanoic acid (5HD, an m-KATP channel blocker, at 10 mg/kg, before high-dose fasudil. Myocardial infarct size was expressed as a percentage of area at risk (AAR. Results Under normoglycemia, low-dose and high-dose fasudil and diazoxide reduced myocardial infarct size (23 ± 8%, 21 ± 9% and 21 ± 10% of AAR, respectively compared with that in the control (42 ± 7%. Under hyperglycemia, low-dose fasudil (40 ± 11% and diazoxide (44 ± 14% could not exert this beneficial effect, but high-dose fasudil reduced myocardial infarct size in the same manner as under normoglycemia (21 ± 13%. 5HD prevented fasudil-induced reduction of myocardial infarct size (42 ± 13%. Conclusion Fasudil induces PostC against myocardial infarction via activation of m-KATP channels in the rat. Although hyperglycemia attenuates the PostC, high-dose fasudil can restore cardioprotection.

  11. Clinical use of 201Tl myocardial scintigraphy

    International Nuclear Information System (INIS)

    Senda, Kohei; Imaeda, Takeyoshi; Kato, Toshimitsu; Asada, Shuichi; Doi, Hidetaka

    1977-01-01

    Myocardial imaging with 201 Tl and scinticamera was studied experimentally using specially designed phantoms and clinically in 23 patients with myocardial infarction or other heart disease. In the phantom experiment, quality of image, accumulative count rate, and detectability of the defect were compared to obtain the best technique for their detection, using four different collimators, i.e., converging, pin-hole, 4000-hole, and 140 keV high-resolution, at two photopeak levels of 201 Tl of 75 and 167 keV, and combining a radiation absorber. In patient examination, myocardial images taken at different periods after injection, different detecting conditions of the scinticamera, and various detecting projections were compared. Images of the converging collimator at the 75 keV photopeak revealed considerably higher accumulative counts and relatively higher quality than those of other detecting conditions. It was necessary to take as many images as possible in various projections, in order to detect the location and size of the myocardial ischemic lesion because the lesion was demonstrated as a clear defect only in profile. It became evident that images taken between about 25 and 90 min delineated the myocardium more clearly than those taken in other periods. Normal images taken in 8 patients without ischemic heart disease appeared in the shape of a doughnut of horseshoe, demonstrating mainly the left venticular myocardium. The image was faint in the region of the aortic or mitral valve and thin in the region of the apical wall. A faint image of the right ventricular myocardium was sometimes seen. In 3 patients with valvular heart disease, findings suggested changes in the thickness of myocardium and the distribution of coronary blood flow. In 11 of 12 patients with old myocardial infarction, the location and size of the lesion was detected. (Evans, J.)

  12. Ultra-high resolution protein crystallography

    International Nuclear Information System (INIS)

    Takeda, Kazuki; Hirano, Yu; Miki, Kunio

    2010-01-01

    Many protein structures have been determined by X-ray crystallography and deposited with the Protein Data Bank. However, these structures at usual resolution (1.5< d<3.0 A) are insufficient in their precision and quantity for elucidating the molecular mechanism of protein functions directly from structural information. Several studies at ultra-high resolution (d<0.8 A) have been performed with synchrotron radiation in the last decade. The highest resolution of the protein crystals was achieved at 0.54 A resolution for a small protein, crambin. In such high resolution crystals, almost all of hydrogen atoms of proteins and some hydrogen atoms of bound water molecules are experimentally observed. In addition, outer-shell electrons of proteins can be analyzed by the multipole refinement procedure. However, the influence of X-rays should be precisely estimated in order to derive meaningful information from the crystallographic results. In this review, we summarize refinement procedures, current status and perspectives for ultra high resolution protein crystallography. (author)

  13. Off-pump supra-arterial myotomy for myocardial bridging.

    Science.gov (United States)

    Crespo, Alejandro; Aramendi, José I; Hamzeh, Gadah; Voces, Roberto

    2008-09-01

    We report the results of surgery and midterm outcome in two patients with symptomatic myocardial bridging who underwent off-pump supra-arterial myotomy. Both patients were operated upon through a median sternotomy. The anterior wall of the heart was exposed in the same manner as in off-pump CABG. The left anterior descending coronary artery is unroofed from its myocardial bridge with the aid of a heart stabilizer and a blower. Neither heparin nor blood transfusion was required. Both patients survived the operation and are asymptomatic. Postoperative coronary angiogram showed good resolution of the muscle bridge in one patient. We conclude that in symptomatic patients with myocardial bridging despite medical therapy, surgical myotomy can be considered an adequate therapy. It can be safely done off-pump.

  14. Magnetic resonance imaging using paramagnetic contrast agents in the clinical evaluation of myocardial infarction. Chapter 15

    International Nuclear Information System (INIS)

    Dijkman, P.R.M. van; Wall, E.E. van der

    1992-01-01

    MRI is noninvasive and specific method for production of high resolution tomographic images in blocks of 3D information. Apart from scintigraphic techniques and computed tomography for evaluation of myocardial ischemia and infarcts, MRI has emerged as a new diagnostic technique to study the extent of anatomical and functional abnormalities in patients with coronary artery disease. Conventional noncontrast MRI can identify acute-infarcted myocardial areas, although the difficulty in identifying myocardial ischemia and infarct with noncontrast MRI suggests a potential role for contrast enhanced MRI. Use of the paramagnetic contrast agent gadolinium diethylene triamine pentaacetic acid (Gd-DTPA) improves depiction of infarcted myocardium on T1-weighted spin -echo MR images that are obtained soon after acute myocardial infarction. This is of particular interest for the estimation of myocardial infarct size. Furthermore, ultrafast subsecond imaging, in combination with Gd-DTPA, offers the potential to analyze cardiac first pass and myocardial perfusion. The development of nontoxic paramagnetic contrast agents which are selectively taken up by viable myocardium would be helpful in assessing the presence of ischemic/infarcted myocardium salvage by MRI following reperfusion. (author). 58 refs., 6 figs

  15. Myocardial perfusion in silent myocardial ischemia

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa

    1989-01-01

    To investigate myocardial perfusion in silent myocardial ischemia, we performed exercise stress myocardial tomography with thallium-201 (Tl) in 85 patients with coronary artery disease (CAD). Exercise stress myocardial tomography was obtained both immediately after exercise and three hours later. Patients were classified into two groups according to the presence (Symptomatic Group, n=36) or absence (Silent Group, n=49) of chest pain during exercise stress. Clinical features (age, gender and history of myocardial infarction) and arteriographically determined severity of CAD were the same in both groups. The extent of myocardial ischemia (% Ischemia) estimated by exercise stress myocardial tomography was the same in each group (30±10 % in Silent Group, 28±12 % in Symptomatic Group, NS). The severity of exercise-induced myocardial ischemia was expressed as a minimal value of myocardial Tl washout rate (minimal WOR) of each patient. Although exercise heart rate was identical in both groups, minimal WOR in Silent Group was significantly higher than that of Symptomatic Group (4±10% vs -16±14%, p<0.001). The study in patients who exhibited both silent and symptomatic ischemia showed the same results. These findings suggest that the severity of ischemia is a fundamental factor in determining the presence or absence of pain during exercise induced ischemia. (author)

  16. High-Sensitivity C-Reactive Protein as a Predictor of Cardiovascular Events after ST-Elevation Myocardial Infarction

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Daniel Rios Pinto; Ramos, Adriane Monserrat; Vieira, Pedro Lima; Menti, Eduardo; Bordin, Odemir Luiz Jr.; Souza, Priscilla Azambuja Lopes de; Quadros, Alexandre Schaan de; Portal, Vera Lúcia, E-mail: veraportal.pesquisa@gmail.com [Programa de Pós-Graduação em Ciências da Saúde: Cardiologia - Instituto de Cardiologia/Fundação Universitária de Cardiologia, Porto Alegre, RS (Brazil)

    2014-07-15

    The association between high-sensitivity C-reactive protein and recurrent major adverse cardiovascular events (MACE) in patients with ST-elevation myocardial infarction who undergo primary percutaneous coronary intervention remains controversial. To investigate the potential association between high-sensitivity C-reactive protein and an increased risk of MACE such as death, heart failure, reinfarction, and new revascularization in patients with ST-elevation myocardial infarction treated with primary percutaneous coronary intervention. This prospective cohort study included 300 individuals aged >18 years who were diagnosed with ST-elevation myocardial infarction and underwent primary percutaneous coronary intervention at a tertiary health center. An instrument evaluating clinical variables and the Thrombolysis in Myocardial Infarction (TIMI) and Global Registry of Acute Coronary Events (GRACE) risk scores was used. High-sensitivity C-reactive protein was determined by nephelometry. The patients were followed-up during hospitalization and up to 30 days after infarction for the occurrence of MACE. Student's t, Mann-Whitney, chi-square, and logistic regression tests were used for statistical analyses. P values of ≤0.05 were considered statistically significant. The mean age was 59.76 years, and 69.3% of patients were male. No statistically significant association was observed between high-sensitivity C-reactive protein and recurrent MACE (p = 0.11). However, high-sensitivity C-reactive protein was independently associated with 30-day mortality when adjusted for TIMI [odds ratio (OR), 1.27; 95% confidence interval (CI), 1.07-1.51; p = 0.005] and GRACE (OR, 1.26; 95% CI, 1.06-1.49; p = 0.007) risk scores. Although high-sensitivity C-reactive protein was not predictive of combined major cardiovascular events within 30 days after ST-elevation myocardial infarction in patients who underwent primary angioplasty and stent implantation, it was an independent predictor

  17. High resolution solar observations

    International Nuclear Information System (INIS)

    Title, A.

    1985-01-01

    Currently there is a world-wide effort to develop optical technology required for large diffraction limited telescopes that must operate with high optical fluxes. These developments can be used to significantly improve high resolution solar telescopes both on the ground and in space. When looking at the problem of high resolution observations it is essential to keep in mind that a diffraction limited telescope is an interferometer. Even a 30 cm aperture telescope, which is small for high resolution observations, is a big interferometer. Meter class and above diffraction limited telescopes can be expected to be very unforgiving of inattention to details. Unfortunately, even when an earth based telescope has perfect optics there are still problems with the quality of its optical path. The optical path includes not only the interior of the telescope, but also the immediate interface between the telescope and the atmosphere, and finally the atmosphere itself

  18. High speed, High resolution terahertz spectrometers

    International Nuclear Information System (INIS)

    Kim, Youngchan; Yee, Dae Su; Yi, Miwoo; Ahn, Jaewook

    2008-01-01

    A variety of sources and methods have been developed for terahertz spectroscopy during almost two decades. Terahertz time domain spectroscopy (THz TDS)has attracted particular attention as a basic measurement method in the fields of THz science and technology. Recently, asynchronous optical sampling (AOS)THz TDS has been demonstrated, featuring rapid data acquisition and a high spectral resolution. Also, terahertz frequency comb spectroscopy (TFCS)possesses attractive features for high precision terahertz spectroscopy. In this presentation, we report on these two types of terahertz spectrometer. Our high speed, high resolution terahertz spectrometer is demonstrated using two mode locked femtosecond lasers with slightly different repetition frequencies without a mechanical delay stage. The repetition frequencies of the two femtosecond lasers are stabilized by use of two phase locked loops sharing the same reference oscillator. The time resolution of our terahertz spectrometer is measured using the cross correlation method to be 270 fs. AOS THz TDS is presented in Fig. 1, which shows a time domain waveform rapidly acquired on a 10ns time window. The inset shows a zoom into the signal with 100ps time window. The spectrum obtained by the fast Fourier Transformation (FFT)of the time domain waveform has a frequency resolution of 100MHz. The dependence of the signal to noise ratio (SNR)on the measurement time is also investigated

  19. Myocardial T1 and extracellular volume fraction mapping at 3 tesla

    Directory of Open Access Journals (Sweden)

    Lee Jason J

    2011-11-01

    Full Text Available Abstract Background To compare 11 heartbeat (HB and 17 HB modified lock locker inversion recovery (MOLLI pulse sequence at 3T and to establish preliminary reference values for myocardial T1 and the extracellular volume fraction (ECV. Methods Both phantoms and normal volunteers were scanned at 3T using 11 HB and 17 HB MOLLI sequence with the following parameters: spatial resolution = 1.75 × 1.75 × 10 mm on a 256 × 180 matrix, TI initial = 110 ms, TI increment = 80 ms, flip angle = 35°, TR/TE = 1.9/1.0 ms. All volunteers were administered Gadolinium-DTPA (Magnevist, 0.15 mmol/kg, and multiple post-contrast MOLLI scans were performed at the same pre-contrast position from 3.5-23.5 minutes after a bolus contrast injection. Late gadolinium enhancement (LGE images were also acquired 12-30 minutes after the gadolinium bolus. Results T1 values of 11 HB and 17 HB MOLLI displayed good agreement in both phantom and volunteers. The average pre-contrast myocardial and blood T1 was 1315 ± 39 ms and 2020 ± 129 ms, respectively. ECV was stable between 8.5 to 23.5 minutes post contrast with an average of 26.7 ± 1.0%. Conclusion The 11 HB MOLLI is a faster method for high-resolution myocardial T1 mapping at 3T. ECV fractions are stable over a wide time range after contrast administration.

  20. High-Resolution Sonars: What Resolution Do We Need for Target Recognition?

    Directory of Open Access Journals (Sweden)

    Pailhas Yan

    2010-01-01

    Full Text Available Target recognition in sonar imagery has long been an active research area in the maritime domain, especially in the mine-counter measure context. Recently it has received even more attention as new sensors with increased resolution have been developed; new threats to critical maritime assets and a new paradigm for target recognition based on autonomous platforms have emerged. With the recent introduction of Synthetic Aperture Sonar systems and high-frequency sonars, sonar resolution has dramatically increased and noise levels decreased. Sonar images are distance images but at high resolution they tend to appear visually as optical images. Traditionally algorithms have been developed specifically for imaging sonars because of their limited resolution and high noise levels. With high-resolution sonars, algorithms developed in the image processing field for natural images become applicable. However, the lack of large datasets has hampered the development of such algorithms. Here we present a fast and realistic sonar simulator enabling development and evaluation of such algorithms.We develop a classifier and then analyse its performances using our simulated synthetic sonar images. Finally, we discuss sensor resolution requirements to achieve effective classification of various targets and demonstrate that with high resolution sonars target highlight analysis is the key for target recognition.

  1. Mouse myocardial first-pass perfusion MR imaging

    NARCIS (Netherlands)

    Coolen, Bram F.; Moonen, Rik P. M.; Paulis, Leonie E. M.; Geelen, Tessa; Nicolay, Klaas; Strijkers, Gustav J.

    2010-01-01

    A first-pass myocardial perfusion sequence for mouse cardiac MRI is presented. A segmented ECG-triggered acquisition combined with parallel imaging acceleration was used to capture the first pass of a Gd-DTPA bolus through the mouse heart with a temporal resolution of 300-400 msec. The method was

  2. Clinical use of /sup 201/Tl myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Senda, K; Imaeda, T; Kato, T; Asada, S; Doi, H

    1977-04-01

    Myocardial imaging with /sup 201/Tl and scinticamera was studied experimentally using specially designed phantoms and clinically in 23 patients with myocardial infarction or other heart disease. In the phantom experiment, quality of image, accumulative count rate, and detectability of the defect were compared to obtain the best technique for their detection, using four different collimators, i.e., converging, pin-hole, 4000-hole, and 140 keV high-resolution, at two photopeak levels of /sup 201/Tl of 75 and 167 keV, and combining a radiation absorber. In patient examination, myocardial images taken at different periods after injection, different detecting conditions of the scinticamera, and various detecting projections were compared. Images of the converging collimator at the 75 keV photopeak revealed considerably higher accumulative counts and relatively higher quality than those of other detecting conditions. It was necessary to take as many images as possible in various projections, in order to detect the location and size of the myocardial ischemic lesion because the lesion was demonstrated as a clear defect only in profile. It became evident that images taken between about 25 and 90 min delineated the myocardium more clearly than those taken in other periods. Normal images taken in 8 patients without ischemic heart disease appeared in the shape of a doughnut of horseshoe, demonstrating mainly the left venticular myocardium. The image was faint in the region of the aortic or mitral valve and thin in the region of the apical wall. A faint image of the right ventricular myocardium was sometimes seen. In 3 patients with valvular heart disease, findings suggested changes in the thickness of myocardium and the distribution of coronary blood flow. In 11 of 12 patients with old myocardial infarction, the location and size of the lesion was detected.

  3. Thallium-201 myocardial imaging in acute-myocardial infarction

    International Nuclear Information System (INIS)

    Wackers, F.J.Th.; Lie, K.I.; Sokole, E.B.; Wellens, H.J.J.; Samson, G.; Schoot, J.B. van der

    1980-01-01

    Thallium-201 scintigraphy has proven to be an early and highly sensitive technique to detect myocardial perfusion abnormalities in patients with acute myocardial infarction. During the early phase of acute myocardial infarction, patients may be hemodynamically and electrically unstable. Therefore, scintigraphy is performed preferably at the bed side in the Coronary Care Unit using a mobile gamma camera. Additionally, in order to shorten imaging time in these often critically ill patients, the authors recommend injecting no less than 2 mCi of 201 Tl. Using this dosage, the imaging time per view will be approximately five minutes. Routinely, three views are taken: the first view is a supine 45 0 left-anterior-oblique view, followed by a supine anterior view and finally a left-lateral view, the latter with the patient turned on the right side. (Auth.)

  4. Elevated serum uric acid affects myocardial reperfusion and infarct size in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention.

    Science.gov (United States)

    Mandurino-Mirizzi, Alessandro; Crimi, Gabriele; Raineri, Claudia; Pica, Silvia; Ruffinazzi, Marta; Gianni, Umberto; Repetto, Alessandra; Ferlini, Marco; Marinoni, Barbara; Leonardi, Sergio; De Servi, Stefano; Oltrona Visconti, Luigi; De Ferrari, Gaetano M; Ferrario, Maurizio

    2018-05-01

    Elevated serum uric acid (eSUA) was associated with unfavorable outcome in patients with ST-segment elevation myocardial infarction (STEMI). However, the effect of eSUA on myocardial reperfusion injury and infarct size has been poorly investigated. Our aim was to correlate eSUA with infarct size, infarct size shrinkage, myocardial reperfusion grade and long-term mortality in STEMI patients undergoing primary percutaneous coronary intervention. We performed a post-hoc patients-level analysis of two randomized controlled trials, testing strategies for myocardial ischemia/reperfusion injury protection. Each patient underwent acute (3-5 days) and follow-up (4-6 months) cardiac magnetic resonance. Infarct size and infarct size shrinkage were outcomes of interest. We assessed T2-weighted edema, myocardial blush grade (MBG), corrected Thrombolysis in myocardial infarction Frame Count, ST-segment resolution and long-term all-cause mortality. A total of 101 (86.1% anterior) STEMI patients were included; eSUA was found in 16 (15.8%) patients. Infarct size was larger in eSUA compared with non-eSUA patients (42.3 ± 22 vs. 29.1 ± 15 ml, P = 0.008). After adjusting for covariates, infarct size was 10.3 ml (95% confidence interval 1.2-19.3 ml, P = 0.001) larger in eSUA. Among patients with anterior myocardial infarction the difference in delayed enhancement between groups was maintained (respectively, 42.3 ± 22.4 vs. 29.9 ± 15.4 ml, P = 0.015). Infarct size shrinkage was similar between the groups. Compared with non-eSUA, eSUA patients had larger T2-weighted edema (53.8 vs. 41.2 ml, P = 0.031) and less favorable MBG (MBG < 2: 44.4 vs. 13.6%, P = 0.045). Corrected Thrombolysis in myocardial infarction Frame Count and ST-segment resolution did not significantly differ between the groups. At a median follow-up of 7.3 years, all-cause mortality was higher in the eSUA group (18.8 vs. 2.4%, P = 0.028). eSUA may affect myocardial

  5. Mouse myocardial first-pass perfusion MR imaging

    NARCIS (Netherlands)

    Coolen, B.F.; Moonen, R.P.M.; Paulis, L.E.M.; Geelen, T.; Nicolay, K.; Strijkers, G.J.

    2010-01-01

    A first-pass myocardial perfusion sequence for mouse cardiac MRI is presented. A segmented ECG-triggered acquisition combined with parallel imaging acceleration was used to capture the first pass of a Gd-DTPA bolus through the mouse heart with a temporal resolution of 300–400 msec. The method was

  6. When is reacquisition necessary due to high extra-cardiac uptake in myocardial perfusion scintigraphy?

    DEFF Research Database (Denmark)

    Johansen, Allan; Lomsky, Milan; Gerke, Oke

    2013-01-01

    Technetium-labeled agents, which are most often used for assessing myocardial perfusion in myocardial perfusion scintigraphy (MPS), are cleared by the liver and excreted by the biliary system. Spillover from extra-cardiac activity into the myocardium, especially the inferior wall, might conceal d...... defects and lower the diagnostic accuracy of the study. The objective was to determine rules of thumb for when reacquisition is useful due to high extra-cardiac uptake, i.e., when interpretation of the studies was affected by poor image quality....

  7. In vivo study of myocardial elastography under graded ischemia conditions

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Wei-Ning; Provost, Jean; Konofagou, Elisa E [Department of Biomedical Engineering, Columbia University, New York, NY (United States); Fujikura, Kana [Department of Radiology, Columbia University, New York, NY (United States); Wang Jie, E-mail: ek2191@columbia.edu [Department of Medicine, Columbia University, New York, NY (United States)

    2011-02-21

    The capability of currently available echocardiography-based strain estimation techniques to fully map myocardial abnormality at early stages of myocardial ischemia is yet to be investigated. In this study, myocardial elastography (ME), a radio-frequency (RF)-based strain imaging technique that maps the full 2D transmural angle-independent strain tensor in standard echocardiographic views at both high spatial and temporal resolution is presented. The objectives were to (1) evaluate the performance of ME on mapping the onset, extent and progression of myocardial ischemia at graded coronary constriction levels (from partial to complete coronary flow reduction), and (2) validate the accuracy of the strain estimates against sonomicrometry (SM) measurements. A non-survival canine ischemic model (n = 5) was performed by gradually constricting the left anterior descending (LAD) coronary blood flow from 0% (baseline blood flow) to 100% (zero blood flow) at 20% increments. An open-architecture ultrasound system was used to acquire RF echocardiograms in a standard full short-axis view at the frame rate of 211 fps, at least twice higher than what is typically used in conventional echocardiographic systems, using a previously developed, fully automated composite technique. Myocardial deformation was estimated by ME and validated against sonomicrometry. ME estimates and maps transmural (1) 2D displacements using RF cross-correlation and recorrelation; and (2) 2D polar (radial and circumferential) strains, derived from 2D (i.e. both lateral and axial) displacement components, at high accuracy. Full-view strain images were shown and found to reliably depict decreased myocardial function in the region at risk at increased levels of coronary flow reduction. The ME radial strain was deemed to be a more sensitive, quantitative, regional measure of myocardial ischemia as a result of coronary flow reduction when compared to the conventional wall motion score index and ejection fraction

  8. Peri-procedural ST segment resolution during Primary Percutaneous Coronary Intervention (PPCI) for acute myocardial infarction: predictors and clinical consequences.

    Science.gov (United States)

    Karamasis, Grigoris V; Russhard, Paul; Al Janabi, Firas; Parker, Michael; Davies, John R; Keeble, Thomas R; Clesham, Gerald J

    ECG ST segment resolution (STR) has been used to assess myocardial perfusion in STEMI patients undergoing PPCI. However, in most of the studies ECGs recorded at different time points after the actual procedure have been used, limiting the options of therapeutic interventions while the patient is still in the catheterisation laboratory. The aim of this study was to investigate the presence and clinical consequences of intra-procedural STR during PPCI. We analysed 12 lead ECGs recorded at the onset and the end of the PPCI procedure, measuring STR in the lead with maximum ST elevation on the initial recording. STR was defined as good when > 50% compared to baseline. Pre and immediately post PPCI ECGs were recorded in 467 STEMI cases whilst the patient was on the catheter lab table. Mean patient age was 63 (+/- 12) years old and 75% were men. Mean duration of symptoms to admission was 3.8 (+/- 3.4) hours and 51% of infarcts were anterior. Good ST resolution at the end of the procedure was seen in 46.5% of patients and was observed more commonly in inferior compared to anterior infarcts (60.1% vs. 32.6%, pST resolution had a shorter mean hospital length of stay (3.8 vs. 4.5 days, p=0.009) and a higher left ventricular ejection fraction (49.9% vs. 44.2%, pST resolution was seen in less than half of STEMI patients undergoing PPCI. There were important clinical consequences of good ST resolution. Identification of suboptimal peri-procedural ST resolution could help identify patients who may benefit from new treatments aimed at protecting the microcirculation, whilst the patients are still in the angiography laboratory. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Myocardial scintigraphy

    International Nuclear Information System (INIS)

    Bunko, Hisashi; Hisada, Kinichi

    1982-01-01

    Among the various methods of image diagnosis of the cardiovascular disorder, nuclear cardiology provides noninvasive means for evaluation of myocardial perfusion as well as morphological and functional informations. In this article, clinical application and image diagnosis of myocardial scintigraphy including Tl-201 myocardial perfusion scintigraphy, single photon emission computed tomography with Tl-201, acute myocardial infarction scintigraphy with Tc-99m-pyrophosphate and Ga-67 imaging of the heart, were discussed. Multiplanar imaging of the heart with Tl-201 after stress and at redistribution was the accepted method for detection and evaluation of the ischemic heart disease. Although it achieved high sensitivity and specificity for ischemic heart disease, detection of the small ischemia and quantation of the regional Tl-201 accumulation were difficult with conventional multiplanar imaging. Application of emission computed tomography improved detectability and quantitativity of the ischemia. However, 7-pinhole tomography did not increase the diagnostic accuracy significantly. It had limited clinical applicability due to poor quantitativity in spite of improved image contrast and its tomographic nature. Advantage and limitation of these tomographic imaging and multiplanar imaging were discussed. Problems and prognostic significance of pyrophosphate imaging of the acute myocardial infarction were also discussed. Visualization of the heart with Ga-67 was helpful for identification of the tumor or inflammation of the heart as well as evaluation of the effect of the therapy. (author)

  10. Berkeley High-Resolution Ball

    International Nuclear Information System (INIS)

    Diamond, R.M.

    1984-10-01

    Criteria for a high-resolution γ-ray system are discussed. Desirable properties are high resolution, good response function, and moderate solid angle so as to achieve not only double- but triple-coincidences with good statistics. The Berkeley High-Resolution Ball involved the first use of bismuth germanate (BGO) for anti-Compton shield for Ge detectors. The resulting compact shield permitted rather close packing of 21 detectors around a target. In addition, a small central BGO ball gives the total γ-ray energy and multiplicity, as well as the angular pattern of the γ rays. The 21-detector array is nearly complete, and the central ball has been designed, but not yet constructed. First results taken with 9 detector modules are shown for the nucleus 156 Er. The complex decay scheme indicates a transition from collective rotation (prolate shape) to single- particle states (possibly oblate) near spin 30 h, and has other interesting features

  11. A bi-ventricular cardiac atlas built from 1000+ high resolution MR images of healthy subjects and an analysis of shape and motion.

    Science.gov (United States)

    Bai, Wenjia; Shi, Wenzhe; de Marvao, Antonio; Dawes, Timothy J W; O'Regan, Declan P; Cook, Stuart A; Rueckert, Daniel

    2015-12-01

    Atlases encode valuable anatomical and functional information from a population. In this work, a bi-ventricular cardiac atlas was built from a unique data set, which consists of high resolution cardiac MR images of 1000+ normal subjects. Based on the atlas, statistical methods were used to study the variation of cardiac shapes and the distribution of cardiac motion across the spatio-temporal domain. We have shown how statistical parametric mapping (SPM) can be combined with a general linear model to study the impact of gender and age on regional myocardial wall thickness. Finally, we have also investigated the influence of the population size on atlas construction and atlas-based analysis. The high resolution atlas, the statistical models and the SPM method will benefit more studies on cardiac anatomy and function analysis in the future. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. High spatial resolution and temporally resolved T2* mapping of normal human myocardium at 7.0 Tesla: an ultrahigh field magnetic resonance feasibility study.

    Directory of Open Access Journals (Sweden)

    Fabian Hezel

    Full Text Available Myocardial tissue characterization using T(2(* relaxation mapping techniques is an emerging application of (preclinical cardiovascular magnetic resonance imaging. The increase in microscopic susceptibility at higher magnetic field strengths renders myocardial T(2(* mapping at ultrahigh magnetic fields conceptually appealing. This work demonstrates the feasibility of myocardial T(2(* imaging at 7.0 T and examines the applicability of temporally-resolved and high spatial resolution myocardial T(2(* mapping. In phantom experiments single cardiac phase and dynamic (CINE gradient echo imaging techniques provided similar T(2(* maps. In vivo studies showed that the peak-to-peak B(0 difference following volume selective shimming was reduced to approximately 80 Hz for the four chamber view and mid-ventricular short axis view of the heart and to 65 Hz for the left ventricle. No severe susceptibility artifacts were detected in the septum and in the lateral wall for T(2(* weighting ranging from TE = 2.04 ms to TE = 10.2 ms. For TE >7 ms, a susceptibility weighting induced signal void was observed within the anterior and inferior myocardial segments. The longest T(2(* values were found for anterior (T(2(* = 14.0 ms, anteroseptal (T(2(* = 17.2 ms and inferoseptal (T(2(* = 16.5 ms myocardial segments. Shorter T(2(* values were observed for inferior (T(2(* = 10.6 ms and inferolateral (T(2(* = 11.4 ms segments. A significant difference (p = 0.002 in T(2(* values was observed between end-diastole and end-systole with T(2(* changes of up to approximately 27% over the cardiac cycle which were pronounced in the septum. To conclude, these results underscore the challenges of myocardial T(2(* mapping at 7.0 T but demonstrate that these issues can be offset by using tailored shimming techniques and dedicated acquisition schemes.

  13. Myocardial Bridge

    Science.gov (United States)

    ... Center > Myocardial Bridge Menu Topics Topics FAQs Myocardial Bridge En español Your heart is made of muscle, ... surface of the heart. What is a myocardial bridge? A myocardial bridge is a band of heart ...

  14. Rapid Rule-Out of Acute Myocardial Injury Using a Single High-Sensitivity Cardiac Troponin I Measurement.

    Science.gov (United States)

    Sandoval, Yader; Smith, Stephen W; Shah, Anoop S V; Anand, Atul; Chapman, Andrew R; Love, Sara A; Schulz, Karen; Cao, Jing; Mills, Nicholas L; Apple, Fred S

    2017-01-01

    Rapid rule-out strategies using high-sensitivity cardiac troponin assays are largely supported by studies performed outside the US in selected cohorts of patients with chest pain that are atypical of US practice, and focused exclusively on ruling out acute myocardial infarction (AMI), rather than acute myocardial injury, which is more common and associated with a poor prognosis. Prospective, observational study of consecutive patients presenting to emergency departments [derivation (n = 1647) and validation (n = 2198) cohorts], where high-sensitivity cardiac troponin I (hs-cTnI) was measured on clinical indication. The negative predictive value (NPV) and diagnostic sensitivity of an hs-cTnI concentration rules out acute myocardial injury, regardless of etiology, with an excellent NPV and diagnostic sensitivity, and identifies patients at minimal risk of AMI or cardiac death at 30 days. ClinicalTrials.gov Identifier: NCT02060760. © 2016 American Association for Clinical Chemistry.

  15. High-Resolution PET Detector. Final report

    International Nuclear Information System (INIS)

    Karp, Joel

    2014-01-01

    The objective of this project was to develop an understanding of the limits of performance for a high resolution PET detector using an approach based on continuous scintillation crystals rather than pixelated crystals. The overall goal was to design a high-resolution detector, which requires both high spatial resolution and high sensitivity for 511 keV gammas. Continuous scintillation detectors (Anger cameras) have been used extensively for both single-photon and PET scanners, however, these instruments were based on NaI(Tl) scintillators using relatively large, individual photo-multipliers. In this project we investigated the potential of this type of detector technology to achieve higher spatial resolution through the use of improved scintillator materials and photo-sensors, and modification of the detector surface to optimize the light response function.We achieved an average spatial resolution of 3-mm for a 25-mm thick, LYSO continuous detector using a maximum likelihood position algorithm and shallow slots cut into the entrance surface

  16. Mortality and morbidity remain high despite captopril and/or valsartan therapy in elderly patients with left ventricular systolic dysfunction, heart failure, or both after acute myocardial infarction - Results from the Valsartan in Acute Myocardial Infarction Trial (VALIANT)

    NARCIS (Netherlands)

    White, HD; Aylward, PEG; Huang, Z; Dalby, AJ; Weaver, WD; Barvik, S; Marin-Neto, JA; Murin, J; Nordlander, RO; van Gilst, WH; Zannad, F; McMurray, JJV; Califf, RM; Pfeffer, MA

    2005-01-01

    Background - The elderly constitute an increasing proportion of acute myocardial infarction patients and have disproportionately high mortality and morbidity. Those with heart failure or impaired left ventricular left ventricular function after acute myocardial infarction have high complication and

  17. Imaging Three-Dimensional Myocardial Mechanics Using Navigator-gated Volumetric Spiral Cine DENSE MRI

    Science.gov (United States)

    Zhong, Xiaodong; Spottiswoode, Bruce S.; Meyer, Craig H.; Kramer, Christopher M.; Epstein, Frederick H.

    2010-01-01

    A navigator-gated 3D spiral cine displacement encoding with stimulated echoes (DENSE) pulse sequence for imaging 3D myocardial mechanics was developed. In addition, previously-described 2D post-processing algorithms including phase unwrapping, tissue tracking, and strain tensor calculation for the left ventricle (LV) were extended to 3D. These 3D methods were evaluated in 5 healthy volunteers, using 2D cine DENSE and historical 3D myocardial tagging as reference standards. With an average scan time of 20.5 ± 5.7 minutes, 3D data sets with a matrix size of 128 × 128 × 22, voxel size of 2.8 × 2.8 × 5.0 mm3, and temporal resolution of 32 ms were obtained with displacement encoding in three orthogonal directions. Mean values for end-systolic mid-ventricular mid-wall radial, circumferential, and longitudinal strain were 0.33 ± 0.10, −0.17 ± 0.02, and −0.16 ± 0.02, respectively. Transmural strain gradients were detected in the radial and circumferential directions, reflecting high spatial resolution. Good agreement by linear correlation and Bland-Altman analysis was achieved when comparing normal strains measured by 2D and 3D cine DENSE. Also, the 3D strains, twist, and torsion results obtained by 3D cine DENSE were in good agreement with historical values measured by 3D myocardial tagging. PMID:20574967

  18. High resolution sequence stratigraphy in China

    International Nuclear Information System (INIS)

    Zhang Shangfeng; Zhang Changmin; Yin Yanshi; Yin Taiju

    2008-01-01

    Since high resolution sequence stratigraphy was introduced into China by DENG Hong-wen in 1995, it has been experienced two development stages in China which are the beginning stage of theory research and development of theory research and application, and the stage of theoretical maturity and widely application that is going into. It is proved by practices that high resolution sequence stratigraphy plays more and more important roles in the exploration and development of oil and gas in Chinese continental oil-bearing basin and the research field spreads to the exploration of coal mine, uranium mine and other strata deposits. However, the theory of high resolution sequence stratigraphy still has some shortages, it should be improved in many aspects. The authors point out that high resolution sequence stratigraphy should be characterized quantitatively and modelized by computer techniques. (authors)

  19. Development of AMS high resolution injector system

    International Nuclear Information System (INIS)

    Bao Yiwen; Guan Xialing; Hu Yueming

    2008-01-01

    The Beijing HI-13 tandem accelerator AMS high resolution injector system was developed. The high resolution energy achromatic system consists of an electrostatic analyzer and a magnetic analyzer, which mass resolution can reach 600 and transmission is better than 80%. (authors)

  20. Resolution enhancement of low quality videos using a high-resolution frame

    NARCIS (Netherlands)

    Pham, T.Q.; Van Vliet, L.J.; Schutte, K.

    2006-01-01

    This paper proposes an example-based Super-Resolution (SR) algorithm of compressed videos in the Discrete Cosine Transform (DCT) domain. Input to the system is a Low-Resolution (LR) compressed video together with a High-Resolution (HR) still image of similar content. Using a training set of

  1. High resolution, high speed ultrahigh vacuum microscopy

    International Nuclear Information System (INIS)

    Poppa, Helmut

    2004-01-01

    The history and future of transmission electron microscopy (TEM) is discussed as it refers to the eventual development of instruments and techniques applicable to the real time in situ investigation of surface processes with high resolution. To reach this objective, it was necessary to transform conventional high resolution instruments so that an ultrahigh vacuum (UHV) environment at the sample site was created, that access to the sample by various in situ sample modification procedures was provided, and that in situ sample exchanges with other integrated surface analytical systems became possible. Furthermore, high resolution image acquisition systems had to be developed to take advantage of the high speed imaging capabilities of projection imaging microscopes. These changes to conventional electron microscopy and its uses were slowly realized in a few international laboratories over a period of almost 40 years by a relatively small number of researchers crucially interested in advancing the state of the art of electron microscopy and its applications to diverse areas of interest; often concentrating on the nucleation, growth, and properties of thin films on well defined material surfaces. A part of this review is dedicated to the recognition of the major contributions to surface and thin film science by these pioneers. Finally, some of the important current developments in aberration corrected electron optics and eventual adaptations to in situ UHV microscopy are discussed. As a result of all the path breaking developments that have led to today's highly sophisticated UHV-TEM systems, integrated fundamental studies are now possible that combine many traditional surface science approaches. Combined investigations to date have involved in situ and ex situ surface microscopies such as scanning tunneling microscopy/atomic force microscopy, scanning Auger microscopy, and photoemission electron microscopy, and area-integrating techniques such as x-ray photoelectron

  2. A high resolution solar atlas for fluorescence calculations

    Science.gov (United States)

    Hearn, M. F.; Ohlmacher, J. T.; Schleicher, D. G.

    1983-01-01

    The characteristics required of a solar atlas to be used for studying the fluorescence process in comets are examined. Several sources of low resolution data were combined to provide an absolutely calibrated spectrum from 2250 A to 7000A. Three different sources of high resolution data were also used to cover this same spectral range. The low resolution data were then used to put each high resolution spectrum on an absolute scale. The three high resolution spectra were then combined in their overlap regions to produce a single, absolutely calibrated high resolution spectrum over the entire spectral range.

  3. Relationships of elevated systemic pentraxin-3 levels with high-risk coronary plaque components and impaired myocardial perfusion after percutaneous coronary intervention in patients with ST-elevation acute myocardial infarction.

    Science.gov (United States)

    Kimura, Shigeki; Inagaki, Hiroshi; Haraguchi, Go; Sugiyama, Tomoyo; Miyazaki, Toru; Hatano, Yu; Yoshikawa, Shunji; Ashikaga, Takashi; Isobe, Mitsuaki

    2014-01-01

    We aimed to assess the relationships of pentraxin-3 (PTX3) with coronary plaque components and myocardial perfusion after percutaneous coronary intervention (PCI) in order to clarify the mechanisms underlying the prognostic function of PTX3 in ST-elevation acute myocardial infarction (STEMI) patients. We enrolled 75 STEMI patients who underwent pre-PCI virtual histology (VH)-intravascular ultrasound. Relationships of the systemic pre-PCI PTX3 level with coronary plaque components and post-PCI myocardial blush grade (MBG) were evaluated. Lesions with elevated pre-PCI PTX3 (median ≥3.79ng/ml) had higher frequencies of VH-derived thin-cap fibroatheroma (65.8% vs. 24.3%, P2 on admission (hazard ratio, 5.356; 95% CI, 1.409-20.359; P=0.014) as independent predictors of adverse cardiac events during follow-up. Systemic pre-PCI PTX3 was associated with high-risk plaque components and impaired post-PCI myocardial perfusion. Thus, PTX3 may be a reliable predictor of outcome in STEMI patients.

  4. Myocardial perfusion SPECT imaging in patients with myocardial bridging

    International Nuclear Information System (INIS)

    Fang Wei; Qiu Hong; Yang Weixian; Wang Feng; He Zuoxiang

    2008-01-01

    Objective: Stress myocardial perfusion SPECT imaging was used to assess myocardial ischemia in patients with myocardial bridging. Methods: Ninety-six patients with myocardial bridging of the left anterior descending artery documented by coronary angiography were included in this study. All under- went exercise or pharmacological stress myocardial perfusion SPECT assessing myocardial ischemia. None had prior myocardial infarction. One year follow-up by telephone interview was performed in all patients. Results The mean stenotic severity of systolic phase on angiography was (65 ± 19)%. In the SPECT study, 20 of 96 (20.8%) patients showed abnormal perfusion. This percentage was significantly higher than that of stress electrocardiogram (ECG). The higher positive rate of SPECT perfusion images was showed in the group of patients with severe systolic narrowing (≥75%) than that with mild-to-moderate systolic narrowing (50% vs 6.3%, P<0.001). The prevalence of abnormal image was significantly higher in ELDERLY PEOPLE; patients with STT change on rest ECG than in those with normal rest ECG (54.2% vs 9.7%, P<0.001). During follow-up, one patient with abnormal SPECT perfusion image sustained angina and accepted percutaneous coronary intervention, and no cardiac event occurred in patients with normal images. Conclusions: Stress myocardial perfusion SPECT imaging can be used effectively for assessing myocardial ischemia and has potential prognostic value for patients with myocardial bridging. (authors)

  5. Effect of eating on thallium myocardial imaging

    International Nuclear Information System (INIS)

    Wilson, R.A.; Sullivan, P.J.; Okada, R.D.; Boucher, C.A.; Morris, C.; Pohost, G.M.; Strauss, H.W.

    1986-01-01

    To determine if eating between initial and delayed thallium images alters the appearance of the delayed thallium scan, a prospective study was performed; 184 subjects sent for routine thallium imaging were randomized into two groups, those who ate a meal high in carbohydrates between initial and delayed thallium myocardial images (n = 106), and those who fasted (n = 78). The 201 Tl images were interpreted in blinded fashion for global myocardial and pulmonary clearance of 201 Tl myocardial defects. The eating group had a significantly lower incidence of transient myocardial defects compared to the noneating group (7 percent vs 18 percent, respectively; p less than 0.05). The time between initial and delayed images and the incidence of exercise-induced ischemic ST-segment depression or pathologic Q waves on the electrocardiogram were not significantly different between the two groups. These data suggest that eating a high-carbohydrate meal between initial and delayed 201 Tl images causes increased 201 Tl myocardial clearance rates and may alter 201 Tl myocardial redistribution over time

  6. High-resolution SPECT for small-animal imaging

    International Nuclear Information System (INIS)

    Qi Yujin

    2006-01-01

    This article presents a brief overview of the development of high-resolution SPECT for small-animal imaging. A pinhole collimator has been used for high-resolution animal SPECT to provide better spatial resolution and detection efficiency in comparison with a parallel-hole collimator. The theory of imaging characteristics of the pinhole collimator is presented and the designs of the pinhole aperture are discussed. The detector technologies used for the development of small-animal SPECT and the recent advances are presented. The evolving trend of small-animal SPECT is toward a multi-pinhole and a multi-detector system to obtain a high resolution and also a high detection efficiency. (authors)

  7. High resolution time integration for SN radiation transport

    International Nuclear Information System (INIS)

    Thoreson, Greg; McClarren, Ryan G.; Chang, Jae H.

    2009-01-01

    First-order, second-order, and high resolution time discretization schemes are implemented and studied for the discrete ordinates (S N ) equations. The high resolution method employs a rate of convergence better than first-order, but also suppresses artificial oscillations introduced by second-order schemes in hyperbolic partial differential equations. The high resolution method achieves these properties by nonlinearly adapting the time stencil to use a first-order method in regions where oscillations could be created. We employ a quasi-linear solution scheme to solve the nonlinear equations that arise from the high resolution method. All three methods were compared for accuracy and convergence rates. For non-absorbing problems, both second-order and high resolution converged to the same solution as the first-order with better convergence rates. High resolution is more accurate than first-order and matches or exceeds the second-order method

  8. Myocardial blood flow and its transit time, oxygen utilization, and efficiency of highly endurance-trained human heart.

    Science.gov (United States)

    Heinonen, Ilkka; Kudomi, Nobuyuki; Kemppainen, Jukka; Kiviniemi, Antti; Noponen, Tommi; Luotolahti, Matti; Luoto, Pauliina; Oikonen, Vesa; Sipilä, Hannu T; Kopra, Jaakko; Mononen, Ilkka; Duncker, Dirk J; Knuuti, Juhani; Kalliokoski, Kari K

    2014-07-01

    Highly endurance-trained athlete's heart represents the most extreme form of cardiac adaptation to physical stress, but its circulatory alterations remain obscure. In the present study, myocardial blood flow (MBF), blood mean transit time (MTT), oxygen extraction fraction (OEF) and consumption (MVO2), and efficiency of cardiac work were quantified in highly trained male endurance athletes and control subjects at rest and during supine cycling exercise using [(15)O]-labeled radiotracers and positron emission tomography. Heart rate and MBF were lower in athletes both at rest and during exercise. OEF increased in response to exercise in both groups, but was higher in athletes (70 ± 21 vs. 63 ± 11 % at rest and 86 ± 13 vs. 73 ± 10 % during exercise). MTT was longer and vascular resistance higher in athletes both at rest and during exercise, but arterial content of 2,3-diphosphoglycerate (oxygen affinity) was unchanged. MVO2 per gram of myocardium trended (p = 0.08) lower in athletes both at rest and during exercise, while myocardial efficiency of work and MVO2 per beat were not different between groups. Arterial levels of free fatty acids were ~twofold higher in athletes likely leading to higher myocardial fatty acid oxidation and hence oxygen cost, which may have blunted the bradycardia-induced decrease in MVO2. Finally, the observed group differences in MBF, OEF, MTT and vascular resistance remained significant also after they were controlled for differences in MVO2. In conclusion, in highly endurance-trained human heart, increased myocardial blood transition time enables higher oxygen extraction levels with a lower myocardial blood flow and higher vascular resistance. These physiological adaptations to exercise training occur independently of the level of oxygen consumption and together with training-induced bradycardia may serve as mechanisms to increase functional reserve of the human heart.

  9. High tracking resolution detectors. Final Technical Report

    International Nuclear Information System (INIS)

    Vasile, Stefan; Li, Zheng

    2010-01-01

    High-resolution tracking detectors based on Active Pixel Sensor (APS) have been valuable tools in Nuclear Physics and High-Energy Physics research, and have contributed to major discoveries. Their integration time, radiation length and readout rate is a limiting factor for the planed luminosity upgrades in nuclear and high-energy physics collider-based experiments. The goal of this program was to demonstrate and develop high-gain, high-resolution tracking detector arrays with faster readout, and shorter radiation length than APS arrays. These arrays may operate as direct charged particle detectors or as readouts of high resolution scintillating fiber arrays. During this program, we developed in CMOS large, high-resolution pixel sensor arrays with integrated readout, and reset at pixel level. Their intrinsic gain, high immunity to surface and moisture damage, will allow operating these detectors with minimal packaging/passivation requirements and will result in radiation length superior to APS. In Phase I, we designed and fabricated arrays with calorimetric output capable of sub-pixel resolution and sub-microsecond readout rate. The technical effort was dedicated to detector and readout structure development, performance verification, as well as to radiation damage and damage annealing.

  10. Ultra high resolution tomography

    Energy Technology Data Exchange (ETDEWEB)

    Haddad, W.S.

    1994-11-15

    Recent work and results on ultra high resolution three dimensional imaging with soft x-rays will be presented. This work is aimed at determining microscopic three dimensional structure of biological and material specimens. Three dimensional reconstructed images of a microscopic test object will be presented; the reconstruction has a resolution on the order of 1000 A in all three dimensions. Preliminary work with biological samples will also be shown, and the experimental and numerical methods used will be discussed.

  11. QRS slopes for assessment of myocardial damage in chronic chagasic patients

    International Nuclear Information System (INIS)

    Pueyo, E; Laciar, E; Anzuola, E; Laguna, P; Jane, R

    2007-01-01

    In this study the slopes of the QRS complex are evaluated for determination of the degree of myocardial damage in chronic chagasic patients. Previous studies have demonstrated the ability of the slope indices to reflect alterations in the conduction velocity of the cardiac impulse. Results obtained in the present study show that chronic chagasic patients have significantly flatter QRS slopes as compared to healthy subjects. Not only that but the extent of slope lessening turns out to be proportional to the degree of myocardial damage caused by the disease. Additionally, when incorporating the slope indices into a classification analysis together with other indices indicative of the presence of ventricular late potentials obtained from high resolution electrocardiography, results show that the percentages of correct classification increase up to 62.5%, which means eight points above the percentages obtained prior to incorporation of the slope indices. It can be concluded that QRS slopes have great potential for assessing the degree of severity associated with Chagas' disease

  12. Myocardial scintigraphy: methods and indications

    International Nuclear Information System (INIS)

    Knapp, W.H.

    1993-01-01

    Myocardial scintigraphy comprises perfusion imaging using TI-201 or - more recently - Tc-99m-labeled compounds with high affinity to myocytes. Imaging with these agents has become an important procedure in the detection of coronary artery disease, particularly in patients with non-diagnostic stress-ECG, in the functional evaluation of coronary stenoses after angiographical documentation in order to meet the adequate therapy decision, in therapy monitoring and follow-up, in the post infarction assessment of myocardial viability and differentiation between severe ischemia and scar and, occasionally, in acute ischemia. The use of positron emitters does not offer significant advantages for mere perfusion imaging, but is indispensable for the scintigraphic investigation of certain aspects of myocardial metabolism, particularly for the differentiation of viable ischemic wall segments from irreversibly damaged tissue. Imaging of myocardial necrosis has been improved by the introduction of labeled antimyosin antibody fragments and offers a considerable clinical potential in the diagnosis of myocarditis and cardiac transplant rejection. Neurohumoral aspects are increasingly involved in our understanding of myocardial failure. Scintigraphy of innervation/neurotransmission contributes to the investigation of pathophysiological alterations in myocardial insufficiency and in heart transplants. (orig.) [de

  13. Use of high flip angle in T1-prepared FAST sequences for myocardial perfusion quantification

    International Nuclear Information System (INIS)

    Vallee, Jean-Paul; Ivancevic, Marko; Lazeyras, Francois; Didier, Dominique; Kasuboski, Larry; Chatelain, Pascal; Righetti, Alberto

    2003-01-01

    This study reports on the first use of high flip angle and radio-frequency (RF) spoiling in T1-prepared fast acquisition in steady state (FAST) sequence for myocardial perfusion in patients. T1 dynamic range was measured in vitro with a FAST, an RF FAST and a snapshot fast low-angle shot (FLASH) sequences with a 90 flip angle. Myocardial perfusion was then measured twice in 6 patients during the same MR session. The RF FAST and FLASH, but not the FAST sequence, demonstrated an extended T1 dynamic range; however, the FLASH images were degraded by artifacts not present on the RF FAST images. The myocardial perfusion indices K1 (first-order transfer constant from the blood to the myocardium for the Gd-DTPA) and Vd (distribution volume of Gd-DTPA in myocardium) did not differ significantly between the two injections. K1 was 0.48±0.12 ml/min g -1 and Vd was 12.5±2.9%. With an extended T1 dynamic range and the sensitivity required for myocardial perfusion quantification, the RF FAST sequence with a 90 flip angle outperformed the snapshot FLASH sequence in terms of image quality and the FAST sequence in terms of contrast dynamic range. (orig.)

  14. A high resolution portable spectroscopy system

    International Nuclear Information System (INIS)

    Kulkarni, C.P.; Vaidya, P.P.; Paulson, M.; Bhatnagar, P.V.; Pande, S.S.; Padmini, S.

    2003-01-01

    Full text: This paper describes the system details of a High Resolution Portable Spectroscopy System (HRPSS) developed at Electronics Division, BARC. The system can be used for laboratory class, high-resolution nuclear spectroscopy applications. The HRPSS consists of a specially designed compact NIM bin, with built-in power supplies, accommodating a low power, high resolution MCA, and on-board embedded computer for spectrum building and communication. A NIM based spectroscopy amplifier and a HV module for detector bias are integrated (plug-in) in the bin. The system communicates with a host PC via a serial link. Along-with a laptop PC, and a portable HP-Ge detector, the HRPSS offers a laboratory class performance for portable applications

  15. Influence of Term of Exposure to High-Fat Diet-Induced Obesity on Myocardial Collagen Type I and III

    International Nuclear Information System (INIS)

    Silva, Danielle Cristina Tomaz da; Lima-Leopoldo, Ana Paula; Leopoldo, André Soares; Campos, Dijon Henrique Salomé de; Nascimento, André Ferreira do; Oliveira, Sílvio Assis Junior de; Padovani, Carlos Roberto; Cicogna, Antonio Carlos

    2014-01-01

    Obesity is a risk factor for many medical complications; medical research has shown that hemodynamic, morphological and functional abnormalities are correlated with the duration and severity of obesity. Present study determined the influence of term of exposure to high-fat diet-induced obesity on myocardial collagen type I and III. Thirty-day-old male Wistar rats were randomly distributed into two groups: a control (C) group fed a standard rat chow and an obese (Ob) group alternately fed one of four palatable high-fat diets. Each diet was changed daily, and the rats were maintained on their respective diets for 15 (C 15 and Ob 15 ) and 30 (C 30 and Ob 30 ) consecutive weeks. Obesity was determined by adiposity index. The Ob 15 group was similar to the C 15 group regarding the expression of myocardial collagen type I; however, expression in the Ob 30 group was less than C 30 group. The time of exposure to obesity was associated with a reduction in collagen type I in Ob 30 when compared with Ob 15 . Obesity did not affect collagen type III expression. This study showed that the time of exposure to obesity for 30 weeks induced by unsaturated high-fat diet caused a reduction in myocardial collagen type I expression in the obese rats. However, no effect was seen on myocardial collagen type III expression

  16. Evaluation of Parallel and Fan-Beam Data Acquisition Geometries and Strategies for Myocardial SPECT Imaging

    Science.gov (United States)

    Qi, Yujin; Tsui, B. M. W.; Gilland, K. L.; Frey, E. C.; Gullberg, G. T.

    2004-06-01

    This study evaluates myocardial SPECT images obtained from parallel-hole (PH) and fan-beam (FB) collimator geometries using both circular-orbit (CO) and noncircular-orbit (NCO) acquisitions. A newly developed 4-D NURBS-based cardiac-torso (NCAT) phantom was used to simulate the /sup 99m/Tc-sestamibi uptakes in human torso with myocardial defects in the left ventricular (LV) wall. Two phantoms were generated to simulate patients with thick and thin body builds. Projection data including the effects of attenuation, collimator-detector response and scatter were generated using SIMSET Monte Carlo simulations. A large number of photon histories were generated such that the projection data were close to noise free. Poisson noise fluctuations were then added to simulate the count densities found in clinical data. Noise-free and noisy projection data were reconstructed using the iterative OS-EM reconstruction algorithm with attenuation compensation. The reconstructed images from noisy projection data show that the noise levels are lower for the FB as compared to the PH collimator due to increase in detected counts. The NCO acquisition method provides slightly better resolution and small improvement in defect contrast as compared to the CO acquisition method in noise-free reconstructed images. Despite lower projection counts the NCO shows the same noise level as the CO in the attenuation corrected reconstruction images. The results from the channelized Hotelling observer (CHO) study show that FB collimator is superior to PH collimator in myocardial defect detection, but the NCO shows no statistical significant difference from the CO for either PH or FB collimator. In conclusion, our results indicate that data acquisition using NCO makes a very small improvement in the resolution over CO for myocardial SPECT imaging. This small improvement does not make a significant difference on myocardial defect detection. However, an FB collimator provides better defect detection than a

  17. High Resolution Elevation Contours

    Data.gov (United States)

    Minnesota Department of Natural Resources — This dataset contains contours generated from high resolution data sources such as LiDAR. Generally speaking this data is 2 foot or less contour interval.

  18. Extension of least squares spectral resolution algorithm to high-resolution lipidomics data

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Ying-Xu [Department of Chemistry, University of Bergen, PO Box 7803, N-5020 Bergen (Norway); Mjøs, Svein Are, E-mail: svein.mjos@kj.uib.no [Department of Chemistry, University of Bergen, PO Box 7803, N-5020 Bergen (Norway); David, Fabrice P.A. [Bioinformatics and Biostatistics Core Facility, School of Life Sciences, Ecole Polytechnique Fédérale de Lausanne (EPFL) and Swiss Institute of Bioinformatics (SIB), Lausanne (Switzerland); Schmid, Adrien W. [Proteomics Core Facility, Ecole Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne (Switzerland)

    2016-03-31

    Lipidomics, which focuses on the global study of molecular lipids in biological systems, has been driven tremendously by technical advances in mass spectrometry (MS) instrumentation, particularly high-resolution MS. This requires powerful computational tools that handle the high-throughput lipidomics data analysis. To address this issue, a novel computational tool has been developed for the analysis of high-resolution MS data, including the data pretreatment, visualization, automated identification, deconvolution and quantification of lipid species. The algorithm features the customized generation of a lipid compound library and mass spectral library, which covers the major lipid classes such as glycerolipids, glycerophospholipids and sphingolipids. Next, the algorithm performs least squares resolution of spectra and chromatograms based on the theoretical isotope distribution of molecular ions, which enables automated identification and quantification of molecular lipid species. Currently, this methodology supports analysis of both high and low resolution MS as well as liquid chromatography-MS (LC-MS) lipidomics data. The flexibility of the methodology allows it to be expanded to support more lipid classes and more data interpretation functions, making it a promising tool in lipidomic data analysis. - Highlights: • A flexible strategy for analyzing MS and LC-MS data of lipid molecules is proposed. • Isotope distribution spectra of theoretically possible compounds were generated. • High resolution MS and LC-MS data were resolved by least squares spectral resolution. • The method proposed compounds that are likely to occur in the analyzed samples. • The proposed compounds matched results from manual interpretation of fragment spectra.

  19. Extension of least squares spectral resolution algorithm to high-resolution lipidomics data

    International Nuclear Information System (INIS)

    Zeng, Ying-Xu; Mjøs, Svein Are; David, Fabrice P.A.; Schmid, Adrien W.

    2016-01-01

    Lipidomics, which focuses on the global study of molecular lipids in biological systems, has been driven tremendously by technical advances in mass spectrometry (MS) instrumentation, particularly high-resolution MS. This requires powerful computational tools that handle the high-throughput lipidomics data analysis. To address this issue, a novel computational tool has been developed for the analysis of high-resolution MS data, including the data pretreatment, visualization, automated identification, deconvolution and quantification of lipid species. The algorithm features the customized generation of a lipid compound library and mass spectral library, which covers the major lipid classes such as glycerolipids, glycerophospholipids and sphingolipids. Next, the algorithm performs least squares resolution of spectra and chromatograms based on the theoretical isotope distribution of molecular ions, which enables automated identification and quantification of molecular lipid species. Currently, this methodology supports analysis of both high and low resolution MS as well as liquid chromatography-MS (LC-MS) lipidomics data. The flexibility of the methodology allows it to be expanded to support more lipid classes and more data interpretation functions, making it a promising tool in lipidomic data analysis. - Highlights: • A flexible strategy for analyzing MS and LC-MS data of lipid molecules is proposed. • Isotope distribution spectra of theoretically possible compounds were generated. • High resolution MS and LC-MS data were resolved by least squares spectral resolution. • The method proposed compounds that are likely to occur in the analyzed samples. • The proposed compounds matched results from manual interpretation of fragment spectra.

  20. Ultra-high resolution coded wavefront sensor

    KAUST Repository

    Wang, Congli

    2017-06-08

    Wavefront sensors and more general phase retrieval methods have recently attracted a lot of attention in a host of application domains, ranging from astronomy to scientific imaging and microscopy. In this paper, we introduce a new class of sensor, the Coded Wavefront Sensor, which provides high spatio-temporal resolution using a simple masked sensor under white light illumination. Specifically, we demonstrate megapixel spatial resolution and phase accuracy better than 0.1 wavelengths at reconstruction rates of 50 Hz or more, thus opening up many new applications from high-resolution adaptive optics to real-time phase retrieval in microscopy.

  1. Three-dimension structure of ventricular myocardial fibers after myocardial infarction

    Directory of Open Access Journals (Sweden)

    Li Libin

    2010-11-01

    Full Text Available Abstract Background To explore the pathological changes of three-dimension structure of ventricular myocardial fibers after anterior myocardial infarction in dog heart. Methods Fourteen acute anterior myocardial infarction models were made from healthy dogs (mean weight 17.6 ± 2.5 kg. Six out of 14 dogs with old myocardial infarction were sacrificed, and their hearts were harvested after they survived the acute anterior myocardial infarction for 3 months. Each heart was dissected into ventricular myocardial band (VMB, morphological characters in infarction region were observed, and infarct size percents in descending segment and ascending segment were calculated. Results Six dog hearts were successfully dissected into VMB. Uncorresponding damages in myocardial fibers of descending segment and ascending segment were found in apical circle in anterior wall infarction. Infarct size percent in the ascending segment was significantly larger than that in the descending segment (23.36 ± 3.15 (SD vs 30.69 ± 2.40%, P = 0.0033; the long axis of infarction area was perpendicular to the orientation of myocardial fibers in ascending segment; however, the long axis of the infarction area was parallel with the orientation of myocardial fibers in descending segment. Conclusions We found that damages were different in both morphology and size in ascending segment and descending segment in heart with myocardial infarction. This may provide an important insight for us to understand the mechanism of heart failure following coronary artery diseases.

  2. Effect of perindopril on the myocardial energy consumption in patients with heart failure after myocardial infarction

    Directory of Open Access Journals (Sweden)

    Da-Peng Li

    2017-07-01

    Full Text Available Objective: To explore the clinical efficacy of perinodopril in the treatment of heart failure in patients after myocardial infarction and effect on the myocardial energy consumption. Methods: A total of 87 patients with heart failure after myocardial infarction who were admitted in our hospital from August, 2014 to October, 2015 were included in the study and divided into the routine dose group (n=43, perinodopril 4 mg/d and high dose group (n=44, perinodopril 8 mg/d according to the long-term oral dose. All the patients were given perinodopril, continuously for 6 months. The changes of blood pressure and serum biochemical indicators before and after treatment in the two groups were compared. The changes of cardiac function indicators and myocardial energy consumption indicators before and after treatment in the two groups were compared. 6MWT 6 months and 1 year after treatment in the two groups was calculated. Results: The plasma BNP and H-FABP levels, LVEDD, LVESD, MEE, and cESS after treatment in the two groups were significantly reduced when compared with before treatment, and those in the high dose group were significantly lower than those in the low dose group. LVEF and FS after treatment in the two groups were significantly increased, and those in the high dose group were significantly greater than those in the routine dose group. The seurm potassium level after treatment in the high dose group was significantly elevated when compared with before treatment, but was not significantly different from that in the routine dose group. SBP, DBP, and Scr levels after treatment in the two groups were not significantly changed. 6MWT 6 months and 1 year after treatment in the high dose group was significantly greater than that in the routine dose group. Conclusions: Perinodopril in a high dose can significantly reduce the plasma BNP and H-FABP levels in patients with heart failure after myocardial infarction, inhibit the ventricular remodeling

  3. Nitrogen-13-labeled ammonia for myocardial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, W.F.; Fill, H.R.; Harper, P.V.

    1977-01-01

    Cyclotron-produced nitrogen-13 (half-life 10 min), as labeled ammonia (/sup 13/NH/sub 4//sup +/), has been evaluated as a myocardial perfusion imaging agent. The regional myocardial uptake of /sup 13/NH/sub 4//sup +/ has been shown to be proportional to regional tissue perfusion in animal studies. Intravenously administered /sup 13/NH/sub 4//sup +/ is rapidly cleared from the circulation, being extracted by the liver (15 percent), lungs, myocardium (2 percent--4 percent), brain, kidney, and bladder. Myocardial ammonia is metabolized mainly to glutamine via the glutamine synthetase pathway. Pulmonary uptake is substantial, but usually transient, except in smokers where clearance may be delayed. The positron annihilation irradiation (511 keV) of /sup 13/N may be imaged with a scintillation camera, using either a specially designed tungsten collimator or a pinhole collimator. After early technical problems with collimation and the production method of /sup 13/NH/sub 4//sup +/ were overcome, reproducible high quality myocardial images were consistently obtained. The normal myocardial image was established to be of a homogeneous ''doughnut'' configuration. Imaging studies performed in patients with varying manifestations of ischemic and valvular heart disease showed a high incidence of localized perfusion defects, especially in patients with acute myocardial infarction. Sequential studies at short intervals in patients with acute infarction showed correlation between alterations in regional perfusion and the clinical course of the patient. It is concluded that myocardial imaging with /sup 13/NH/sub 4//sup +/ and a scintillation camera provides a valid and noninvasive means of assessing regional myocardial perfusion. This method is especially suitable for sequential studies of acute cardiac patients at short intervals. Coincidence imaging of the 511 keV annihilation irradiation provides a tomographic and potentially quantitative assessment of the

  4. High resolution data acquisition

    Science.gov (United States)

    Thornton, Glenn W.; Fuller, Kenneth R.

    1993-01-01

    A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock (38) pulse train (37) and analog circuitry (44) for generating a triangular wave (46) synchronously with the pulse train (37). The triangular wave (46) has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter (18, 32) forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter (26) counts the clock pulse train (37) during the interval to form a gross event interval time. A computer (52) then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.

  5. Mechanical ventilation with high tidal volumes attenuates myocardial dysfunction by decreasing cardiac edema in a rat model of LPS-induced peritonitis

    Directory of Open Access Journals (Sweden)

    Smeding Lonneke

    2012-03-01

    Full Text Available Abstract Background Injurious mechanical ventilation (MV may augment organ injury remote from the lungs. During sepsis, myocardial dysfunction is common and increased endothelial activation and permeability can cause myocardial edema, which may, among other factors, hamper myocardial function. We investigated the effects of MV with injuriously high tidal volumes on the myocardium in an animal model of sepsis. Methods Normal rats and intraperitoneal (i.p. lipopolysaccharide (LPS-treated rats were ventilated with low (6 ml/kg and high (19 ml/kg tidal volumes (Vt under general anesthesia. Non-ventilated animals served as controls. Mean arterial pressure (MAP, central venous pressure (CVP, cardiac output (CO and pulmonary plateau pressure (Pplat were measured. Ex vivo myocardial function was measured in isolated Langendorff-perfused hearts. Cardiac expression of endothelial vascular cell adhesion molecule (VCAM-1 and edema were measured to evaluate endothelial inflammation and leakage. Results MAP decreased after LPS-treatment and Vt-dependently, both independent of each other and with interaction. MV Vt-dependently increased CVP and Pplat and decreased CO. LPS-induced peritonitis decreased myocardial function ex vivo but MV attenuated systolic dysfunction Vt-dependently. Cardiac endothelial VCAM-1 expression was increased by LPS treatment independent of MV. Cardiac edema was lowered Vt-dependently by MV, particularly after LPS, and correlated inversely with systolic myocardial function parameters ex vivo. Conclusion MV attenuated LPS-induced systolic myocardial dysfunction in a Vt-dependent manner. This was associated with a reduction in cardiac edema following a lower transmural coronary venous outflow pressure during LPS-induced coronary inflammation.

  6. High resolution time integration for Sn radiation transport

    International Nuclear Information System (INIS)

    Thoreson, Greg; McClarren, Ryan G.; Chang, Jae H.

    2008-01-01

    First order, second order and high resolution time discretization schemes are implemented and studied for the S n equations. The high resolution method employs a rate of convergence better than first order, but also suppresses artificial oscillations introduced by second order schemes in hyperbolic differential equations. All three methods were compared for accuracy and convergence rates. For non-absorbing problems, both second order and high resolution converged to the same solution as the first order with better convergence rates. High resolution is more accurate than first order and matches or exceeds the second order method. (authors)

  7. Structure of high-resolution NMR spectra

    CERN Document Server

    Corio, PL

    2012-01-01

    Structure of High-Resolution NMR Spectra provides the principles, theories, and mathematical and physical concepts of high-resolution nuclear magnetic resonance spectra.The book presents the elementary theory of magnetic resonance; the quantum mechanical theory of angular momentum; the general theory of steady state spectra; and multiple quantum transitions, double resonance and spin echo experiments.Physicists, chemists, and researchers will find the book a valuable reference text.

  8. Echocardiography diagnosis of myocardial infarction complications

    Directory of Open Access Journals (Sweden)

    N.D. Oryshchyn

    2016-03-01

    Full Text Available Diagnosis and management of myocardial infarction complications are discussed in this article. These complications are associated with high level of mortality and surgery is a main treatment method. High level of suspicion and early diagnosis are essential for appropriate treatment and improvement of prognosis. Echocardiography is a main diagnostic method. Analysis of literature about contemporary management of mechanical complications of myocardial infarction has been performed, case reports are presented.

  9. Is the effect of job strain on myocardial infarction risk due to interaction between high psychological demands and low decision latitude?

    DEFF Research Database (Denmark)

    Hallqvist, J; Diderichsen, Finn; Theorell, T

    1998-01-01

    The objectives are to examine if the excess risk of myocardial infarction from exposure to job strain is due to interaction between high demands and low control and to analyse what role such an interaction has regarding socioeconomic differences in risk of myocardial infarction. The material...

  10. Influence of Term of Exposure to High-Fat Diet-Induced Obesity on Myocardial Collagen Type I and III

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Danielle Cristina Tomaz da [Departamento de Clínica Médica, Faculdade de Medicina de Botucatu, Universidade Estadual Paulista (UNESP), Botucatu, SP (Brazil); Lima-Leopoldo, Ana Paula; Leopoldo, André Soares [Departamento de Esportes, Centro de Educação Física e Desportos da Universidade Federal do Espírito Santo (UFES), Vitória, ES (Brazil); Campos, Dijon Henrique Salomé de; Nascimento, André Ferreira do [Departamento de Clínica Médica, Faculdade de Medicina de Botucatu, Universidade Estadual Paulista (UNESP), Botucatu, SP (Brazil); Oliveira, Sílvio Assis Junior de [Escola de Fisioterapia da Universidade Federal de Mato Grosso do Sul (UFMS), Campo Grande, MS (Brazil); Padovani, Carlos Roberto [Departamento de Bioestatística do Instituto de Ciências Biológicas da Universidade Estadual Paulista (UNESP), Botucatu, SP (Brazil); Cicogna, Antonio Carlos, E-mail: dany.tomaz@gmail.com [Departamento de Clínica Médica, Faculdade de Medicina de Botucatu, Universidade Estadual Paulista (UNESP), Botucatu, SP (Brazil)

    2014-02-15

    Obesity is a risk factor for many medical complications; medical research has shown that hemodynamic, morphological and functional abnormalities are correlated with the duration and severity of obesity. Present study determined the influence of term of exposure to high-fat diet-induced obesity on myocardial collagen type I and III. Thirty-day-old male Wistar rats were randomly distributed into two groups: a control (C) group fed a standard rat chow and an obese (Ob) group alternately fed one of four palatable high-fat diets. Each diet was changed daily, and the rats were maintained on their respective diets for 15 (C{sub 15} and Ob{sub 15}) and 30 (C{sub 30} and Ob{sub 30}) consecutive weeks. Obesity was determined by adiposity index. The Ob{sub 15} group was similar to the C{sub 15} group regarding the expression of myocardial collagen type I; however, expression in the Ob{sub 30} group was less than C{sub 30} group. The time of exposure to obesity was associated with a reduction in collagen type I in Ob{sub 30} when compared with Ob{sub 15}. Obesity did not affect collagen type III expression. This study showed that the time of exposure to obesity for 30 weeks induced by unsaturated high-fat diet caused a reduction in myocardial collagen type I expression in the obese rats. However, no effect was seen on myocardial collagen type III expression.

  11. High-resolution multi-slice PET

    International Nuclear Information System (INIS)

    Yasillo, N.J.; Chintu Chen; Ordonez, C.E.; Kapp, O.H.; Sosnowski, J.; Beck, R.N.

    1992-01-01

    This report evaluates the progress to test the feasibility and to initiate the design of a high resolution multi-slice PET system. The following specific areas were evaluated: detector development and testing; electronics configuration and design; mechanical design; and system simulation. The design and construction of a multiple-slice, high-resolution positron tomograph will provide substantial improvements in the accuracy and reproducibility of measurements of the distribution of activity concentrations in the brain. The range of functional brain research and our understanding of local brain function will be greatly extended when the development of this instrumentation is completed

  12. High resolution NMR spectroscopy of synthetic polymers in bulk

    International Nuclear Information System (INIS)

    Komorski, R.A.

    1986-01-01

    The contents of this book are: Overview of high-resolution NMR of solid polymers; High-resolution NMR of glassy amorphous polymers; Carbon-13 solid-state NMR of semicrystalline polymers; Conformational analysis of polymers of solid-state NMR; High-resolution NMR studies of oriented polymers; High-resolution solid-state NMR of protons in polymers; and Deuterium NMR of solid polymers. This work brings together the various approaches for high-resolution NMR studies of bulk polymers into one volume. Heavy emphasis is, of course, given to 13C NMR studies both above and below Tg. Standard high-power pulse and wide-line techniques are not covered

  13. Myocardial infarction

    International Nuclear Information System (INIS)

    Ando, Jyoji; Yasuda, Hisakazu; Miyamoto, Atsushi; Kobayashi, Tsuyoshi

    1980-01-01

    sup(99m)Tc-pyrophosphate (PYP) scintigraphy and 201 Tl myocardial scintigraphy were utilized for the diagnoses of the presence, the region, and the extent of myocardial infarction. Exercise 201 Tl myocardial scintigrams and exercise radionuclide ventriculography were utilized for diagnosis of coronary artery lesions in angina pectoris. Radionuclide ventriculography was used to investigate effects of coronary artery lesions on cardiac function and hemodynamics. In order to select adequate treatments for myocardial infarction and estimate the prognosis, it was necessary to detect the presence, the region, and the extent of acute myocardial infarction and to investigate effects of partial infarction on hemodynamics by using radionuclide imaging. Exercise myocardial scintigraphy could be carried out noninvasively and repeatedly for diagnosis of coronal artery disease. Therefore, this method could be applied widely. It was possible to use this method as a screening test of coronary artery diseases for the diagnoses of asymptomatic patients who showed ST changes in ECG, the patients with cardiac neurosis and the patency after a reconstructive surgery of coronary artery. (Tsunoda, M.)

  14. High resolution integral holography using Fourier ptychographic approach.

    Science.gov (United States)

    Li, Zhaohui; Zhang, Jianqi; Wang, Xiaorui; Liu, Delian

    2014-12-29

    An innovative approach is proposed for calculating high resolution computer generated integral holograms by using the Fourier Ptychographic (FP) algorithm. The approach initializes a high resolution complex hologram with a random guess, and then stitches together low resolution multi-view images, synthesized from the elemental images captured by integral imaging (II), to recover the high resolution hologram through an iterative retrieval with FP constrains. This paper begins with an analysis of the principle of hologram synthesis from multi-projections, followed by an accurate determination of the constrains required in the Fourier ptychographic integral-holography (FPIH). Next, the procedure of the approach is described in detail. Finally, optical reconstructions are performed and the results are demonstrated. Theoretical analysis and experiments show that our proposed approach can reconstruct 3D scenes with high resolution.

  15. High-spatial resolution and high-spectral resolution detector for use in the measurement of solar flare hard x rays

    International Nuclear Information System (INIS)

    Desai, U.D.; Orwig, L.E.

    1988-01-01

    In the areas of high spatial resolution, the evaluation of a hard X-ray detector with 65 micron spatial resolution for operation in the energy range from 30 to 400 keV is proposed. The basic detector is a thick large-area scintillator faceplate, composed of a matrix of high-density scintillating glass fibers, attached to a proximity type image intensifier tube with a resistive-anode digital readout system. Such a detector, combined with a coded-aperture mask, would be ideal for use as a modest-sized hard X-ray imaging instrument up to X-ray energies as high as several hundred keV. As an integral part of this study it was also proposed that several techniques be critically evaluated for X-ray image coding which could be used with this detector. In the area of high spectral resolution, it is proposed to evaluate two different types of detectors for use as X-ray spectrometers for solar flares: planar silicon detectors and high-purity germanium detectors (HPGe). Instruments utilizing these high-spatial-resolution detectors for hard X-ray imaging measurements from 30 to 400 keV and high-spectral-resolution detectors for measurements over a similar energy range would be ideally suited for making crucial solar flare observations during the upcoming maximum in the solar cycle

  16. High resolution photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Arko, A.J.

    1988-01-01

    Photoelectron Spectroscopy (PES) covers a very broad range of measurements, disciplines, and interests. As the next generation light source, the FEL will result in improvements over the undulator that are larger than the undulater improvements over bending magnets. The combination of high flux and high inherent resolution will result in several orders of magnitude gain in signal to noise over measurements using synchrotron-based undulators. The latter still require monochromators. Their resolution is invariably strongly energy-dependent so that in the regions of interest for many experiments (h upsilon > 100 eV) they will not have a resolving power much over 1000. In order to study some of the interesting phenomena in actinides (heavy fermions e.g.) one would need resolving powers of 10 4 to 10 5 . These values are only reachable with the FEL

  17. High-resolution regional climate model evaluation using variable-resolution CESM over California

    Science.gov (United States)

    Huang, X.; Rhoades, A.; Ullrich, P. A.; Zarzycki, C. M.

    2015-12-01

    Understanding the effect of climate change at regional scales remains a topic of intensive research. Though computational constraints remain a problem, high horizontal resolution is needed to represent topographic forcing, which is a significant driver of local climate variability. Although regional climate models (RCMs) have traditionally been used at these scales, variable-resolution global climate models (VRGCMs) have recently arisen as an alternative for studying regional weather and climate allowing two-way interaction between these domains without the need for nudging. In this study, the recently developed variable-resolution option within the Community Earth System Model (CESM) is assessed for long-term regional climate modeling over California. Our variable-resolution simulations will focus on relatively high resolutions for climate assessment, namely 28km and 14km regional resolution, which are much more typical for dynamically downscaled studies. For comparison with the more widely used RCM method, the Weather Research and Forecasting (WRF) model will be used for simulations at 27km and 9km. All simulations use the AMIP (Atmospheric Model Intercomparison Project) protocols. The time period is from 1979-01-01 to 2005-12-31 (UTC), and year 1979 was discarded as spin up time. The mean climatology across California's diverse climate zones, including temperature and precipitation, is analyzed and contrasted with the Weather Research and Forcasting (WRF) model (as a traditional RCM), regional reanalysis, gridded observational datasets and uniform high-resolution CESM at 0.25 degree with the finite volume (FV) dynamical core. The results show that variable-resolution CESM is competitive in representing regional climatology on both annual and seasonal time scales. This assessment adds value to the use of VRGCMs for projecting climate change over the coming century and improve our understanding of both past and future regional climate related to fine

  18. Section on High Resolution Optical Imaging (HROI)

    Data.gov (United States)

    Federal Laboratory Consortium — The Section on High Resolution Optical Imaging (HROI) develops novel technologies for studying biological processes at unprecedented speed and resolution. Research...

  19. Relation of plasma lipoprotein(a) with myocardial viability and left ventricular performance in survivors of myocardial infarction

    International Nuclear Information System (INIS)

    Aksoy, M.; Goktekin, O.; Gursurer, M.; Emre, A.; Bilge, M.; Yesilcimen, K.; Ersek, B.; Kepekci, Y.; Akdemir, I.

    1999-01-01

    Previous studies have reported that high serum lipoprotein(a) levels may be responsible for total occlusion of the infarct-related artery via inhibition of intrinsic fibrinolysis during acute myocardial infarction. We evaluated whether this would result in a greater extent of myocardial necrosis and impaired left ventricular function in patients with high lipoprotein(a) levels. Sixty-eight patients with prior myocardial infarction, who were not receiving thrombolytic therapy underwent coronary angiography and stress-redistribution-reinjection Tl-201 scintigraphy. Antegrade TIMI flow in the infarct-related artery was lower (1.54±1.14 vs 2.15±1.05; p=0.03) and the collateral index was higher (1.3±1.0 vs 0.8±0.9; p=0.07) in patients with high lipoprotein(a) levels (>30 mg/dl) compared to those with low lipoprotein(a) levels (≤30 mg/dl). Regional wall motion score index was lower (0.8±0.8 vs 1.4±0.5; p=0.008) and global ejection fraction was higher (46±10% vs 40±11%; p=0.03) in patients with low lipoprotein(a) levels. On SPECT images, the number of nonviable defects was higher in patients with high lipoprotein(a) levels (4.0±2.5 vs 1.9±1.3; p=0.0002), whereas the number of viable defects was higher in those with low lipoprotein(a) levels (2.5±1.8 vs 1.5±1.3; p=0.02). We conclude, that high lipoprotein(a) levels may prolong the occlusion of infarct-related artery during acute myocardial infarction and lead to a greater extent of myocardial necrosis and impaired left ventricular function. (author)

  20. Myocardial Bridging

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    2016-02-01

    Full Text Available Abstract Myocardial bridging is rare. Myocardial bridges are most commonly localized in the middle segment of the left anterior descending coronary artery. The anatomic features of the bridges vary significantly. Alterations of the endothelial morphology and the vasoactive agents impact on the progression of atherosclerosis of myocardial bridging. Patients may present with chest pain, myocardial infarction, arrhythmia and even sudden death. Patients who respond poorly to the medical treatment with β-blockers warrant a surgical intervention. Myotomy is a preferred surgical procedure for the symptomatic patients. Coronary stent deployment has been in limited use due to the unsatisfactory long-term results.

  1. High angular resolution at LBT

    Science.gov (United States)

    Conrad, A.; Arcidiacono, C.; Bertero, M.; Boccacci, P.; Davies, A. G.; Defrere, D.; de Kleer, K.; De Pater, I.; Hinz, P.; Hofmann, K. H.; La Camera, A.; Leisenring, J.; Kürster, M.; Rathbun, J. A.; Schertl, D.; Skemer, A.; Skrutskie, M.; Spencer, J. R.; Veillet, C.; Weigelt, G.; Woodward, C. E.

    2015-12-01

    High angular resolution from ground-based observatories stands as a key technology for advancing planetary science. In the window between the angular resolution achievable with 8-10 meter class telescopes, and the 23-to-40 meter giants of the future, LBT provides a glimpse of what the next generation of instruments providing higher angular resolution will provide. We present first ever resolved images of an Io eruption site taken from the ground, images of Io's Loki Patera taken with Fizeau imaging at the 22.8 meter LBT [Conrad, et al., AJ, 2015]. We will also present preliminary analysis of two data sets acquired during the 2015 opposition: L-band fringes at Kurdalagon and an occultation of Loki and Pele by Europa (see figure). The light curves from this occultation will yield an order of magnitude improvement in spatial resolution along the path of ingress and egress. We will conclude by providing an overview of the overall benefit of recent and future advances in angular resolution for planetary science.

  2. A method for generating high resolution satellite image time series

    Science.gov (United States)

    Guo, Tao

    2014-10-01

    There is an increasing demand for satellite remote sensing data with both high spatial and temporal resolution in many applications. But it still is a challenge to simultaneously improve spatial resolution and temporal frequency due to the technical limits of current satellite observation systems. To this end, much R&D efforts have been ongoing for years and lead to some successes roughly in two aspects, one includes super resolution, pan-sharpen etc. methods which can effectively enhance the spatial resolution and generate good visual effects, but hardly preserve spectral signatures and result in inadequate analytical value, on the other hand, time interpolation is a straight forward method to increase temporal frequency, however it increase little informative contents in fact. In this paper we presented a novel method to simulate high resolution time series data by combing low resolution time series data and a very small number of high resolution data only. Our method starts with a pair of high and low resolution data set, and then a spatial registration is done by introducing LDA model to map high and low resolution pixels correspondingly. Afterwards, temporal change information is captured through a comparison of low resolution time series data, and then projected onto the high resolution data plane and assigned to each high resolution pixel according to the predefined temporal change patterns of each type of ground objects. Finally the simulated high resolution data is generated. A preliminary experiment shows that our method can simulate a high resolution data with a reasonable accuracy. The contribution of our method is to enable timely monitoring of temporal changes through analysis of time sequence of low resolution images only, and usage of costly high resolution data can be reduces as much as possible, and it presents a highly effective way to build up an economically operational monitoring solution for agriculture, forest, land use investigation

  3. Mechanisms of thallium-201 myocardial accumulation

    International Nuclear Information System (INIS)

    Wackers, F.J.Th.; Samson, G.

    1980-01-01

    The practical advantages of 201 Tl over other suitable myocardial imaging agents such as potassium-43 ( 43 K), rubidium-81 ( 81 Rb), and cesium-129 ( 129 Cs), are its relatively low energy photons which makes it possible to employ high-resolution low-energy collimators and its physical half-life of 73 hr which provides sufficiently long shelf-life for practical clinical imaging. Toxicological considerations do not play a role using 201 Tl as thallous chloride. The concentration of thallous chloride in a dose of 2 mCi of 201 Tl is less than 4μg. The LD 50 of thallous chloride is a factor 10 4 more. The minimal lethal dose in man is reported to be 12 mg/kg. The kinetics of 201 Tl, its tissue distributions and radiation doses are assessed, and the effect of cardiac drugs on thallium-201 uptake are discussed. (Auth.)

  4. Resolution enhancement of low-quality videos using a high-resolution frame

    Science.gov (United States)

    Pham, Tuan Q.; van Vliet, Lucas J.; Schutte, Klamer

    2006-01-01

    This paper proposes an example-based Super-Resolution (SR) algorithm of compressed videos in the Discrete Cosine Transform (DCT) domain. Input to the system is a Low-Resolution (LR) compressed video together with a High-Resolution (HR) still image of similar content. Using a training set of corresponding LR-HR pairs of image patches from the HR still image, high-frequency details are transferred from the HR source to the LR video. The DCT-domain algorithm is much faster than example-based SR in spatial domain 6 because of a reduction in search dimensionality, which is a direct result of the compact and uncorrelated DCT representation. Fast searching techniques like tree-structure vector quantization 16 and coherence search1 are also key to the improved efficiency. Preliminary results on MJPEG sequence show promising result of the DCT-domain SR synthesis approach.

  5. A cloud mask methodology for high resolution remote sensing data combining information from high and medium resolution optical sensors

    Science.gov (United States)

    Sedano, Fernando; Kempeneers, Pieter; Strobl, Peter; Kucera, Jan; Vogt, Peter; Seebach, Lucia; San-Miguel-Ayanz, Jesús

    2011-09-01

    This study presents a novel cloud masking approach for high resolution remote sensing images in the context of land cover mapping. As an advantage to traditional methods, the approach does not rely on thermal bands and it is applicable to images from most high resolution earth observation remote sensing sensors. The methodology couples pixel-based seed identification and object-based region growing. The seed identification stage relies on pixel value comparison between high resolution images and cloud free composites at lower spatial resolution from almost simultaneously acquired dates. The methodology was tested taking SPOT4-HRVIR, SPOT5-HRG and IRS-LISS III as high resolution images and cloud free MODIS composites as reference images. The selected scenes included a wide range of cloud types and surface features. The resulting cloud masks were evaluated through visual comparison. They were also compared with ad-hoc independently generated cloud masks and with the automatic cloud cover assessment algorithm (ACCA). In general the results showed an agreement in detected clouds higher than 95% for clouds larger than 50 ha. The approach produced consistent results identifying and mapping clouds of different type and size over various land surfaces including natural vegetation, agriculture land, built-up areas, water bodies and snow.

  6. Quantitative Myocardial Perfusion Imaging Versus Visual Analysis in Diagnosing Myocardial Ischemia: A CE-MARC Substudy.

    Science.gov (United States)

    Biglands, John D; Ibraheem, Montasir; Magee, Derek R; Radjenovic, Aleksandra; Plein, Sven; Greenwood, John P

    2018-05-01

    This study sought to compare the diagnostic accuracy of visual and quantitative analyses of myocardial perfusion cardiovascular magnetic resonance against a reference standard of quantitative coronary angiography. Visual analysis of perfusion cardiovascular magnetic resonance studies for assessing myocardial perfusion has been shown to have high diagnostic accuracy for coronary artery disease. However, only a few small studies have assessed the diagnostic accuracy of quantitative myocardial perfusion. This retrospective study included 128 patients randomly selected from the CE-MARC (Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease) study population such that the distribution of risk factors and disease status was proportionate to the full population. Visual analysis results of cardiovascular magnetic resonance perfusion images, by consensus of 2 expert readers, were taken from the original study reports. Quantitative myocardial blood flow estimates were obtained using Fermi-constrained deconvolution. The reference standard for myocardial ischemia was a quantitative coronary x-ray angiogram stenosis severity of ≥70% diameter in any coronary artery of >2 mm diameter, or ≥50% in the left main stem. Diagnostic performance was calculated using receiver-operating characteristic curve analysis. The area under the curve for visual analysis was 0.88 (95% confidence interval: 0.81 to 0.95) with a sensitivity of 81.0% (95% confidence interval: 69.1% to 92.8%) and specificity of 86.0% (95% confidence interval: 78.7% to 93.4%). For quantitative stress myocardial blood flow the area under the curve was 0.89 (95% confidence interval: 0.83 to 0.96) with a sensitivity of 87.5% (95% confidence interval: 77.3% to 97.7%) and specificity of 84.5% (95% confidence interval: 76.8% to 92.3%). There was no statistically significant difference between the diagnostic performance of quantitative and visual analyses (p = 0.72). Incorporating rest myocardial

  7. Immediate rule-out of acute myocardial infarction using electrocardiogram and baseline high-sensitivity troponin I

    DEFF Research Database (Denmark)

    Neumann, Johannes Tobias; Sörensen, Nils Arne; Ojeda, Francisco

    2017-01-01

    AIMS: Serial measurements of high-sensitivity troponin are used to rule out acute myocardial infarction (AMI) with an assay specific cutoff at the 99th percentile. Here, we evaluated the performance of a single admission troponin with a lower cutoff combined with a low risk electrocardiogram (ECG...

  8. High-Resolution Mass Spectrometers

    Science.gov (United States)

    Marshall, Alan G.; Hendrickson, Christopher L.

    2008-07-01

    Over the past decade, mass spectrometry has been revolutionized by access to instruments of increasingly high mass-resolving power. For small molecules up to ˜400 Da (e.g., drugs, metabolites, and various natural organic mixtures ranging from foods to petroleum), it is possible to determine elemental compositions (CcHhNnOoSsPp…) of thousands of chemical components simultaneously from accurate mass measurements (the same can be done up to 1000 Da if additional information is included). At higher mass, it becomes possible to identify proteins (including posttranslational modifications) from proteolytic peptides, as well as lipids, glycoconjugates, and other biological components. At even higher mass (˜100,000 Da or higher), it is possible to characterize posttranslational modifications of intact proteins and to map the binding surfaces of large biomolecule complexes. Here we review the principles and techniques of the highest-resolution analytical mass spectrometers (time-of-flight and Fourier transform ion cyclotron resonance and orbitrap mass analyzers) and describe some representative high-resolution applications.

  9. USGS High Resolution Orthoimagery Collection - Historical - National Geospatial Data Asset (NGDA) High Resolution Orthoimagery

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — USGS high resolution orthorectified images from The National Map combine the image characteristics of an aerial photograph with the geometric qualities of a map. An...

  10. High throughput screening of ligand binding to macromolecules using high resolution powder diffraction

    Science.gov (United States)

    Von Dreele, Robert B.; D'Amico, Kevin

    2006-10-31

    A process is provided for the high throughput screening of binding of ligands to macromolecules using high resolution powder diffraction data including producing a first sample slurry of a selected polycrystalline macromolecule material and a solvent, producing a second sample slurry of a selected polycrystalline macromolecule material, one or more ligands and the solvent, obtaining a high resolution powder diffraction pattern on each of said first sample slurry and the second sample slurry, and, comparing the high resolution powder diffraction pattern of the first sample slurry and the high resolution powder diffraction pattern of the second sample slurry whereby a difference in the high resolution powder diffraction patterns of the first sample slurry and the second sample slurry provides a positive indication for the formation of a complex between the selected polycrystalline macromolecule material and at least one of the one or more ligands.

  11. Oral High-Dose Multivitamins and Minerals or Post Myocardial Infarction Patients in TACT

    Science.gov (United States)

    Lamas, Gervasio A.; Boineau, Robin; Goertz, Christine; Mark, Daniel B.; Rosenberg, Yves; Stylianou, Mario; Rozema, Theodore; Nahin, Richard L.; Lindblad, Lauren; Lewis, Eldrin F.; Drisko, Jeanne; Lee, Kerry L.

    2014-01-01

    Background Oral multivitamins and minerals are often used in conjunction with ethylenediamine tetra acetic acid infusions to treat atherosclerotic disease. Whether high-dose multivitamins are effective as secondary prevention of atherosclerotic disease, however, has not been established. Objective The vitamin component of the Trial to Assess Chelation Therapy assessed whether oral multivitamins reduced cardiovascular events, and were safe. Design The Trial to Assess Chelation Therapy was designed as a double-blind placebo-controlled 2×2 factorial multicenter randomized trial. Setting 134 US and Canadian academic and clinical sites participated. Patients 1708 patients, age ≥50 years, ≥6 weeks post myocardial infarction, with creatinine level ≤ 176.8 µmol/L (2.0 mg/dL). (ClinicalTrials.gov: NCT00044213). Intervention Patients were randomly assigned to an oral 28-component high-dose multivitamin and multimineral mixture or placebo. Measurements Study results were analyzed per randomized group. The primary endpoint was time to total mortality, recurrent myocardial infarction, stroke, coronary revascularization, or hospitalization for angina. Limited secondary endpoints and subgroup analyses were also pre-specified. Results The median age was 65 years, 18% female. The qualifying myocardial infarction had occurred 4.6 (1.6, 9.2) years prior to enrollment. The median duration of follow-up was 55 months (IQR 26, 60) overall. The median number of months during which patients took their vitamins was 31 (13, 59) in the active treatment group, and 35 (13, 60) in the placebo group (p=0.65). There were 645 (76%) vitamin patients and 646 (76%) placebo patients who completed at least 1 year of oral therapy (p=0.98); and 400 (46.9%) vitamin patients and 426 (49.8%) placebo patients who completed at least 3 years of oral therapy (p=0.23). There were 783 (46%) of patients who discontinued their vitamin regimen (390 (46%) in placebo, 394 (46%) in active; p=0.67), and 17% of

  12. Texton-based super-resolution for achieving high spatiotemporal resolution in hybrid camera system

    Science.gov (United States)

    Kamimura, Kenji; Tsumura, Norimichi; Nakaguchi, Toshiya; Miyake, Yoichi

    2010-05-01

    Many super-resolution methods have been proposed to enhance the spatial resolution of images by using iteration and multiple input images. In a previous paper, we proposed the example-based super-resolution method to enhance an image through pixel-based texton substitution to reduce the computational cost. In this method, however, we only considered the enhancement of a texture image. In this study, we modified this texton substitution method for a hybrid camera to reduce the required bandwidth of a high-resolution video camera. We applied our algorithm to pairs of high- and low-spatiotemporal-resolution videos, which were synthesized to simulate a hybrid camera. The result showed that the fine detail of the low-resolution video can be reproduced compared with bicubic interpolation and the required bandwidth could be reduced to about 1/5 in a video camera. It was also shown that the peak signal-to-noise ratios (PSNRs) of the images improved by about 6 dB in a trained frame and by 1.0-1.5 dB in a test frame, as determined by comparison with the processed image using bicubic interpolation, and the average PSNRs were higher than those obtained by the well-known Freeman’s patch-based super-resolution method. Compared with that of the Freeman’s patch-based super-resolution method, the computational time of our method was reduced to almost 1/10.

  13. Myocardial perfusion imaging, coronary angiography and histological examination in experimental treatment of Ad-HGF for myocardial infarction

    International Nuclear Information System (INIS)

    Li Jianhua; Feng Jianlin; Cheng Xu; Li Dianfu; Zhang Youfu

    2007-01-01

    Objective: Gene therapy has drawn a great attention. A swine model of adenovirus hepatocyte growth factor(Ad-HGF) treated myocardial infarction(MI) was utilized, with the effect being assessed by rest myocardial perfusion imaging, coronary angiography and histological examination. Methods: Three groups of MI swine treated with Ad-HGF at low dose [n=5, Ad-HGF 10 8 plague forming unit (PFU)/ site], medium dose(n=5, 4 x 10 8 PFU/site), and high dose (n=5, 5 x 10 9 PFU/site), a control group treated with normal saline(NS, n=5) and a blank control group (n=5) underwent rest myocardial perfusion imaging and coronary angiography before and after treatment. The imaging results were analyzed along with histological findings in each group. Results: The state of myocardial perfusion and Rentrop scores remained unchanged in the blank control and NS groups after treatment. Whereas there was a significant improvement in the two variables in all three groups treated with Ad-HGF. The scores of left circumflex coronary artery (LCX) before and after treated were 7.8 ± 1.3 and 16.4 ± 1.1 (low-dose), 8.2 ± 1.6 and 17.6 ± 0.9 (medium-dose), 8.4 ± 1.5 and 19.0 ± 0.7 (high-dose), respectively. No significant differences were noted among the 3 groups. The number of vessels of NS group was markedly less than that of other groups. Conclusion: Myocardial perfusion imaging seems to be more accurate than coronary angiography and histological examination in evaluating the effects of Ad-HGF on myocardial infarction. (authors)

  14. Immersion Gratings for Infrared High-resolution Spectroscopy

    Science.gov (United States)

    Sarugaku, Yuki; Ikeda, Yuji; Kobayashi, Naoto; Kaji, Sayumi; Sukegawa, Takashi; Sugiyama, Shigeru; Nakagawa, Takao; Arasaki, Takayuki; Kondo, Sohei; Nakanishi, Kenshi; Yasui, Chikako; Kawakita, Hideyo

    2016-10-01

    High-resolution spectroscopy in the infrared wavelength range is essential for observations of minor isotopologues, such as HDO for water, and prebiotic organic molecules like hydrocarbons/P-bearing molecules because numerous vibrational molecular bands (including non-polar molecules) are located in this wavelength range. High spectral resolution enables us to detect weak lines without spectral line confusion. This technique has been widely used in planetary sciences, e.g., cometary coma (H2O, CO, and organic molecules), the martian atmosphere (CH4, CO2, H2O and HDO), and the upper atmosphere of gas giants (H3+ and organic molecules such as C2H6). Spectrographs with higher resolution (and higher sensitivity) still have a potential to provide a plenty of findings. However, because the size of spectrographs scales with the spectral resolution, it is difficult to realize it.Immersion grating (IG), which is a diffraction grating wherein the diffraction surface is immersed in a material with a high refractive index (n > 2), provides n times higher spectral resolution compared to a reflective grating of the same size. Because IG reduces the size of spectrograph to 1/n compared to the spectrograph with the same spectral resolution using a conventional reflective grating, it is widely acknowledged as a key optical device to realize compact spectrographs with high spectral resolution.Recently, we succeeded in fabricating a CdZnTe immersion grating with the theoretically predicted diffraction efficiency by machining process using an ultrahigh-precision five-axis processing machine developed by Canon Inc. Using the same technique, we completed a practical germanium (Ge) immersion grating with both a reflection coating on the grating surface and the an AR coating on the entrance surface. It is noteworthy that the wide wavelength range from 2 to 20 um can be covered by the two immersion gratings.In this paper, we present the performances and the applications of the immersion

  15. Assessment of myocardial viability by MR imaging

    International Nuclear Information System (INIS)

    Sandstede, Joern J.W.

    2003-01-01

    Diagnosis of myocardial viability after infarction focuses on the prediction of functional improvement of dysfunctional myocardium after revascularization therapy. Magnetic resonance imaging provides different approaches for the detection of myocardial viability. Measurement of end-diastolic wall thickness is easy to perform and has a high sensitivity, but a low specificity, and can only be used 4 months after myocardial infarction due to infarct healing processes. Low-dose dobutamine stress has a good sensitivity with a high specificity for the prediction of wall motion improvement, but this is only true for patients with a singular dysfunctional area and only slightly depressed cardiac function. Late enhancement allows for direct visualization of necrotic or scarred tissue. By measuring the transmural extent of late enhancement, the probability of mechanical improvement can precisely be given. Imaging of microvascular obstruction by first-pass perfusion or late enhancement gives additional information on viability and patient prognosis. Metabolic imaging techniques, such as 31 P-MR spectroscopy and 23 Na-MR imaging, provide further insights into the mechanisms of myocardial infarction and viability. In conclusion, cardiac MRI offers several clinically usable approaches for the assessment of myocardial viability and will probably become the method of choice in the near future. (orig.)

  16. High resolution tomographic instrument development

    International Nuclear Information System (INIS)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational

  17. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  18. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  19. High resolution heart rate variability analysis in patients with angina pectoris during coronary artery bypass graft surgery

    Science.gov (United States)

    Mironov, V. A.; Mironova, T. F.; Kuvatov, V. A.; Nokhrina, O. Yu.; Kuvatova, E. V.

    2017-12-01

    The purpose of the study is approbation of the capabilities of high-resolution rhythmocardiography (RCG) for the determination of the actual cardiovascular status of operated patients with angina pectoris during coronary artery bypass graft surgery (CABGS) for myocardial revascularization. The research was done by means of a KAP-RK-02-Mikor hardware-software complex with a monitor record and the time- and frequency-domain analyses of heart rate variability (HRV). Monitor records were made at each stage of CABGS in 123 patients. As a result, HRV manifested itself as a fairly adequate and promising method for the determination of the cardiovascular status during CABGS. In addition, the data of the HRV study during CABGS testify to the capability of RCG to determine the high risk of life-threatening cardioarrhythmias before and during operation, to different changes in sinoatrial heart node (SN) dysregulation, and contain the HRV symptoms of a high death risk before, during and after shunting. The loss of the peripheral autonomic sympathetic and parasympathetic control in SN in the form of the autonomic cardioneuropathy syndrome is a predictor of the complications related to CABGS. The obtained data on RCG monitoring of HRV recording are suggestive of wide prospects of the high-resolution RCG method to be used in cardiac surgery as a whole. The actual multivariant dysregulations of SN pacemaker activity testify to its adequacy to the pathophysiology of each period of the cardiac operation, according to the initial ischemic damages and localization of cardiosurgical manipulations during CABGS.

  20. High resolution Neutron and Synchrotron Powder Diffraction

    International Nuclear Information System (INIS)

    Hewat, A.W.

    1986-01-01

    The use of high-resolution powder diffraction has grown rapidly in the past years, with the development of Rietveld (1967) methods of data analysis and new high-resolution diffractometers and multidetectors. The number of publications in this area has increased from a handful per year until 1973 to 150 per year in 1984, with a ten-year total of over 1000. These papers cover a wide area of solid state-chemistry, physics and materials science, and have been grouped under 20 subject headings, ranging from catalysts to zeolites, and from battery electrode materials to pre-stressed superconducting wires. In 1985 two new high-resolution diffractometers are being commissioned, one at the SNS laboratory near Oxford, and one at the ILL in Grenoble. In different ways these machines represent perhaps the ultimate that can be achieved with neutrons and will permit refinement of complex structures with about 250 parameters and unit cell volumes of about 2500 Angstrom/sp3/. The new European Synchotron Facility will complement the Grenoble neutron diffractometers, and extend the role of high-resolution powder diffraction to the direct solution of crystal structures, pioneered in Sweden

  1. High resolution (transformers.

    Science.gov (United States)

    Garcia-Souto, Jose A; Lamela-Rivera, Horacio

    2006-10-16

    A novel fiber-optic interferometric sensor is presented for vibrations measurements and analysis. In this approach, it is shown applied to the vibrations of electrical structures within power transformers. A main feature of the sensor is that an unambiguous optical phase measurement is performed using the direct detection of the interferometer output, without external modulation, for a more compact and stable implementation. High resolution of the interferometric measurement is obtained with this technique (transformers are also highlighted.

  2. High-resolution wavefront control of high-power laser systems

    International Nuclear Information System (INIS)

    Brase, J.; Brown, C.; Carrano, C.; Kartz, M.; Olivier, S.; Pennington, D.; Silva, D.

    1999-01-01

    Nearly every new large-scale laser system application at LLNL has requirements for beam control which exceed the current level of available technology. For applications such as inertial confinement fusion, laser isotope separation, laser machining, and laser the ability to transport significant power to a target while maintaining good beam quality is critical. There are many ways that laser wavefront quality can be degraded. Thermal effects due to the interaction of high-power laser or pump light with the internal optical components or with the ambient gas are common causes of wavefront degradation. For many years, adaptive optics based on thing deformable glass mirrors with piezoelectric or electrostrictive actuators have be used to remove the low-order wavefront errors from high-power laser systems. These adaptive optics systems have successfully improved laser beam quality, but have also generally revealed additional high-spatial-frequency errors, both because the low-order errors have been reduced and because deformable mirrors have often introduced some high-spatial-frequency components due to manufacturing errors. Many current and emerging laser applications fall into the high-resolution category where there is an increased need for the correction of high spatial frequency aberrations which requires correctors with thousands of degrees of freedom. The largest Deformable Mirrors currently available have less than one thousand degrees of freedom at a cost of approximately $1M. A deformable mirror capable of meeting these high spatial resolution requirements would be cost prohibitive. Therefore a new approach using a different wavefront control technology is needed. One new wavefront control approach is the use of liquid-crystal (LC) spatial light modulator (SLM) technology for the controlling the phase of linearly polarized light. Current LC SLM technology provides high-spatial-resolution wavefront control, with hundreds of thousands of degrees of freedom, more

  3. Assessment of myocardial viability by exercise stress myocardial tomography with 201Tl

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa

    1992-01-01

    Exercise stress (Ex) and redistribution (RD) myocardial tomography with Tl-201 has been widely used for evaluating myocardial viability. But recent studies have demonstrated that reinjection (ReI) study following RD study is necessary for detecting reversible ischemic myocardium. On the other hand, decreased myocardial washout of Tl-201 after Ex is an indicator of myocardial ischemia. So we have studied the usefulness of myocardial Tl-201 washout rate (WOR) for the evaluation of myocardial viability by comparing it with ReI images. Ex and RD myocardial tomographies were obtained immediately after Ex and 3 hours later. After RD study a small amount of Tl-201 was injected and ReI imaging was repeated. We studied 64 myocardial segments (in 58 patients with coronary artery disease) in which Ex-induced perfusion defects persisted in RD images. According to the changes of perfusion defects between Ex, RD and ReI images, they were classified into 3 types: Type I; perfusion defect on the RD image was identical to ReI image (75%). Type I was divided into 2 subgroups whether perfusion defect at Ex was unchanged (Ia, 42%) or improved (Ib, 33%) on the RD image. Type II; perfusion defect at Ex was reduced on the RD image and it improved furthermore at ReI image (17%). Type III; perfusion defect was the same at Ex and RD but it was reduced on the ReI image (8%). WOR less than 30% was defined as abnormal when Ex heart rate exceeded 120 bpm and lung-myocardial Tl-201 uptake ratio was less than 0.45. The differentiation between Type Ia and Type III is of great importance. History of myocardial infarction, effort angina and Ex induced ST depression could not differentiate these 2 groups. WOR abnormality was observed in all of Type III, but WOR was normal in Type Ia. In conclusion, WOR abnormality in Ex-RD myocardial imaging is useful for evaluating myocardial viability. ReI imaging is necessary for the precise evaluation of viable muscle mass and for inadequate Ex. (author)

  4. High resolution optical DNA mapping

    Science.gov (United States)

    Baday, Murat

    Many types of diseases including cancer and autism are associated with copy-number variations in the genome. Most of these variations could not be identified with existing sequencing and optical DNA mapping methods. We have developed Multi-color Super-resolution technique, with potential for high throughput and low cost, which can allow us to recognize more of these variations. Our technique has made 10--fold improvement in the resolution of optical DNA mapping. Using a 180 kb BAC clone as a model system, we resolved dense patterns from 108 fluorescent labels of two different colors representing two different sequence-motifs. Overall, a detailed DNA map with 100 bp resolution was achieved, which has the potential to reveal detailed information about genetic variance and to facilitate medical diagnosis of genetic disease.

  5. High-intensity training reduces intermittent hypoxia-induced ER stress and myocardial infarct size.

    Science.gov (United States)

    Bourdier, Guillaume; Flore, Patrice; Sanchez, Hervé; Pepin, Jean-Louis; Belaidi, Elise; Arnaud, Claire

    2016-01-15

    Chronic intermittent hypoxia (IH) is described as the major detrimental factor leading to cardiovascular morbimortality in obstructive sleep apnea (OSA) patients. OSA patients exhibit increased infarct size after a myocardial event, and previous animal studies have shown that chronic IH could be the main mechanism. Endoplasmic reticulum (ER) stress plays a major role in the pathophysiology of cardiovascular disease. High-intensity training (HIT) exerts beneficial effects on the cardiovascular system. Thus, we hypothesized that HIT could prevent IH-induced ER stress and the increase in infarct size. Male Wistar rats were exposed to 21 days of IH (21-5% fraction of inspired O2, 60-s cycle, 8 h/day) or normoxia. After 1 wk of IH alone, rats were submitted daily to both IH and HIT (2 × 24 min, 15-30m/min). Rat hearts were either rapidly frozen to evaluate ER stress by Western blot analysis or submitted to an ischemia-reperfusion protocol ex vivo (30 min of global ischemia/120 min of reperfusion). IH induced cardiac proapoptotic ER stress, characterized by increased expression of glucose-regulated protein kinase 78, phosphorylated protein kinase-like ER kinase, activating transcription factor 4, and C/EBP homologous protein. IH-induced myocardial apoptosis was confirmed by increased expression of cleaved caspase-3. These IH-associated proapoptotic alterations were associated with a significant increase in infarct size (35.4 ± 3.2% vs. 22.7 ± 1.7% of ventricles in IH + sedenary and normoxia + sedentary groups, respectively, P < 0.05). HIT prevented both the IH-induced proapoptotic ER stress and increased myocardial infarct size (28.8 ± 3.9% and 21.0 ± 5.1% in IH + HIT and normoxia + HIT groups, respectively, P = 0.28). In conclusion, these findings suggest that HIT could represent a preventive strategy to limit IH-induced myocardial ischemia-reperfusion damages in OSA patients. Copyright © 2016 the American Physiological Society.

  6. High-Resolution Electronics: Spontaneous Patterning of High-Resolution Electronics via Parallel Vacuum Ultraviolet (Adv. Mater. 31/2016).

    Science.gov (United States)

    Liu, Xuying; Kanehara, Masayuki; Liu, Chuan; Sakamoto, Kenji; Yasuda, Takeshi; Takeya, Jun; Minari, Takeo

    2016-08-01

    On page 6568, T. Minari and co-workers describe spontaneous patterning based on the parallel vacuum ultraviolet (PVUV) technique, enabling the homogeneous integration of complex, high-resolution electronic circuits, even on large-scale, flexible, transparent substrates. Irradiation of PVUV to the hydrophobic polymer surface precisely renders the selected surface into highly wettable regions with sharply defined boundaries, which spontaneously guides a metal nanoparticle ink into a series of circuit lines and gaps with the widths down to a resolution of 1 μm. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Different Causes of Death in Patients with Myocardial Infarction Type 1, Type 2, and Myocardial Injury.

    Science.gov (United States)

    Lambrecht, Sascha; Sarkisian, Laura; Saaby, Lotte; Poulsen, Tina S; Gerke, Oke; Hosbond, Susanne; Diederichsen, Axel C P; Thygesen, Kristian; Mickley, Hans

    2018-05-01

    Data outlining the mortality and the causes of death in patients with type 1 myocardial infarction, type 2 myocardial infarction, and those with myocardial injury are limited. During a 1-year period from January 2010 to January 2011, all hospitalized patients who had cardiac troponin I measured on clinical indication were prospectively studied. Patients with at least one cardiac troponin I value >30 ng/L underwent case ascertainment and individual evaluation by an experienced adjudication committee. Patients were classified as having type 1 myocardial infarction, type 2 myocardial infarction, or myocardial injury according to the criteria of the universal definition of myocardial infarction. Follow-up was ensured until December 31, 2014. Data on mortality and causes of death were obtained from the Danish Civil Registration System and the Danish Register of Causes of Death. Overall, 3762 consecutive patients were followed for a mean of 3.2 years (interquartile range 1.3-3.6 years). All-cause mortality differed significantly among categories: Type 1 myocardial infarction 31.7%, type 2 myocardial infarction 62.2%, myocardial injury 58.7%, and 22.2% in patients with nonelevated troponin values (log-rank test; P causes, vs 42.6% in patients with type 2 myocardial infarction (P = .015) and 41.2% in those with myocardial injury (P causes of death did not differ substantially between patients with type 2 myocardial infarction and those with myocardial injury. Patients with type 2 myocardial infarction and myocardial injury exhibit a significantly higher long-term mortality compared with patients with type 1 myocardial infarction . However, most patients with type 1 myocardial infarction die from cardiovascular causes in contrast to patients with type 2 myocardial infarction and myocardial injury, in whom noncardiovascular causes of death predominate. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. High resolution UV spectroscopy and laser-focused nanofabrication

    NARCIS (Netherlands)

    Myszkiewicz, G.

    2005-01-01

    This thesis combines two at first glance different techniques: High Resolution Laser Induced Fluorescence Spectroscopy (LIF) of small aromatic molecules and Laser Focusing of atoms for Nanofabrication. The thesis starts with the introduction to the high resolution LIF technique of small aromatic

  9. High-resolution spectrometer at PEP

    International Nuclear Information System (INIS)

    Weiss, J.M.; HRS Collaboration.

    1982-01-01

    A description is presented of the High Resolution Spectrometer experiment (PEP-12) now running at PEP. The advanced capabilities of the detector are demonstrated with first physics results expected in the coming months

  10. Evaluation of myocardial preconditioning and adenosine effects in cardioprotection in rat hearts with ischemia-reperfusion injury using 99MTc-glucarate imaging

    International Nuclear Information System (INIS)

    Liu Zhonglin; Barrett, H.H.; Koon Yan Pak

    2004-01-01

    Significant tolerance to myocardial ischemia-reperfusion injury, as assessed by biochemical assay and noninvasive infarct-avid imaging, was induced with an IPC protocol in the rat model. The cardioprotection of IPC could be simulated by adenosine receptor A1 agonist CCPA, or blocked by antagonist SPT. Thus, adenosine mediates protection by ischemic preconditioning in this specific rat heart model. 99mTc-glucarate imaging is not only useful in detecting early ischemia-reperfusion injury, but also invaluable in evaluating the effects of cardioprotective treatments. uantitative anal ses on dynamic images with 99m Tc-glucarate would make it possible to identify myocardial ischemia-reperfusion injury more accurate, and provide a unique tool for evaluation of cardioprotection. The FASTSPECT imaging with the ischenuc-reperfused rat heart model provides a solution-specific approach with high-resolution and fast dynamic acquisition for kinetic studies of new myocardial imaging agents as the evidence of its major role in the present study. (authors)

  11. Myocardial imaging. Coxsackie myocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Wells, R.G.; Ruskin, J.A.; Sty, J.R.

    1986-09-01

    A 3-week-old male neonate with heart failure associated with Coxsackie virus infection was imaged with Tc-99m PYP and TI-201. The abnormal imaging pattern suggested myocardial infarction. Autopsy findings indicated that the cause was myocardial necrosis secondary to an acute inflammatory process. Causes of abnormal myocardial uptake of Tc-99m PYP in pediatrics include infarction, myocarditis, cardiomyopathy, bacterial endocarditis, and trauma. Myocardial imaging cannot provide a specific cause diagnosis. Causes of myocardial infarction in pediatrics are listed in Table 1.

  12. Myocardial imaging. Coxsackie myocarditis

    International Nuclear Information System (INIS)

    Wells, R.G.; Ruskin, J.A.; Sty, J.R.

    1986-01-01

    A 3-week-old male neonate with heart failure associated with Coxsackie virus infection was imaged with Tc-99m PYP and TI-201. The abnormal imaging pattern suggested myocardial infarction. Autopsy findings indicated that the cause was myocardial necrosis secondary to an acute inflammatory process. Causes of abnormal myocardial uptake of Tc-99m PYP in pediatrics include infarction, myocarditis, cardiomyopathy, bacterial endocarditis, and trauma. Myocardial imaging cannot provide a specific cause diagnosis. Causes of myocardial infarction in pediatrics are listed in Table 1

  13. High-resolution structure of the native histone octamer

    International Nuclear Information System (INIS)

    Wood, Christopher M.; Nicholson, James M.; Lambert, Stanley J.; Chantalat, Laurent; Reynolds, Colin D.; Baldwin, John P.

    2005-01-01

    The high-resolution (1.90 Å) model of the native histone octamer allows structural comparisons to be made with the nucleosome-core particle, along with an identification of a likely core-histone binding site. Crystals of native histone octamers (H2A–H2B)–(H4–H3)–(H3′–H4′)–(H2B′–H2A′) from chick erythrocytes in 2 M KCl, 1.35 M potassium phosphate pH 6.9 diffract X-rays to 1.90 Å resolution, yielding a structure with an R work value of 18.7% and an R free of 22.2%. The crystal space group is P6 5 , the asymmetric unit of which contains one complete octamer. This high-resolution model of the histone-core octamer allows further insight into intermolecular interactions, including water molecules, that dock the histone dimers to the tetramer in the nucleosome-core particle and have relevance to nucleosome remodelling. The three key areas analysed are the H2A′–H3–H4 molecular cluster (also H2A–H3′–H4′), the H4–H2B′ interaction (also H4′–H2B) and the H2A′–H4 β-sheet interaction (also H2A–H4′). The latter of these three regions is important to nucleosome remodelling by RNA polymerase II, as it is shown to be a likely core-histone binding site, and its disruption creates an instability in the nucleosome-core particle. A majority of the water molecules in the high-resolution octamer have positions that correlate to similar positions in the high-resolution nucleosome-core particle structure, suggesting that the high-resolution octamer model can be used for comparative studies with the high-resolution nucleosome-core particle

  14. Requirements on high resolution detectors

    Energy Technology Data Exchange (ETDEWEB)

    Koch, A. [European Synchrotron Radiation Facility, Grenoble (France)

    1997-02-01

    For a number of microtomography applications X-ray detectors with a spatial resolution of 1 {mu}m are required. This high spatial resolution will influence and degrade other parameters of secondary importance like detective quantum efficiency (DQE), dynamic range, linearity and frame rate. This note summarizes the most important arguments, for and against those detector systems which could be considered. This article discusses the mutual dependencies between the various figures which characterize a detector, and tries to give some ideas on how to proceed in order to improve present technology.

  15. High-resolution clean-sc

    NARCIS (Netherlands)

    Sijtsma, P.; Snellen, M.

    2016-01-01

    In this paper a high-resolution extension of CLEAN-SC is proposed: HR-CLEAN-SC. Where CLEAN-SC uses peak sources in “dirty maps” to define so-called source components, HR-CLEAN-SC takes advantage of the fact that source components can likewise be derived from points at some distance from the peak,

  16. High coronary artery calcium score affects clinical outcome despite normal stress myocardial perfusion imaging and normal left ventricular ejection fraction

    DEFF Research Database (Denmark)

    Madsen, Claus Juul; Andersen, Kim F; Zerahn, Bo

    2013-01-01

    Normal myocardial perfusion imaging (MPI) indicates a low risk for cardiac death and new ischaemic events. However, the impact of normal MPI combined with a high coronary artery calcium score (CACS) is not clear. The aims of this study were to evaluate the risk of severely elevated CACS and to id......Normal myocardial perfusion imaging (MPI) indicates a low risk for cardiac death and new ischaemic events. However, the impact of normal MPI combined with a high coronary artery calcium score (CACS) is not clear. The aims of this study were to evaluate the risk of severely elevated CACS...

  17. Planning for shallow high resolution seismic surveys

    CSIR Research Space (South Africa)

    Fourie, CJS

    2008-11-01

    Full Text Available of the input wave. This information can be used in conjunction with this spreadsheet to aid the geophysicist in designing shallow high resolution seismic surveys to achieve maximum resolution and penetration. This Excel spreadsheet is available free from...

  18. Study progress of cardiac MRI technology in assessment of myocardial viability after myocardial infarction

    International Nuclear Information System (INIS)

    Wang Jing; Zhang Hao

    2013-01-01

    Acute myocardial infarction (AMI) is one of the most common diseases that cause disability and death around the world. Correctly and effectively assessing the myocardial viability after myocardial infarction can reduce the disabled rate and mortality rate. At present, many methods could be used to assess myocardial viability. The cardiac magnetic resonance imaging (CMR) technology has a lot of advantages compared to other methods. In this paper, we reviewed the research progress of CMR in assessment of myocardial viability after myocardial infarction, and compared CMR with other technologies. (authors)

  19. The diagnosis of silent myocardial ischemia. Motion-Frozen (or morphing) myocardial perfusion imaging.

    Science.gov (United States)

    Chang, Cheng; Ye, Bo; Xie, Wenhui; Zhang, Daoliang; Lei, Bei; Ye, Xiaodan

    2016-01-01

    Silent myocardial ischemia is typically defined as objective evidence of myocardial ischemia in patients without subjective ischemia symptoms. Currently, coronary artery angiography is the gold standard for diagnosis of asymptomatic coronary artery disease (CAD). Computed tomography coronary angiography (CTCA) can visually demonstrate the morphology, trend and extent of coronary stenosis and is commonly used in clinical screening of CAD. Myocardial perfusion imaging can be used not only to identify whether anatomical stenosis causes myocardial dysfunction, but to also assess the risk stratification and prognosis of myocardial disease (MD). Myocardial perfusion imaging using morphing combined with CTCA can simultaneously show the relationship between CAD and myocardial ischemia from an anatomical and functional aspect. This allows earlier diagnosis of asymptomatic CAD myocardial ischemia, accurate identification of the culprit vessels, and could prevent unnecessary interventional therapy. The 1-day dobutamine stress/resting met-hod is also one of the methods used. The combination of CTCA and the morphing technique can provide anatomical and functional information on coronary arteries at the same time, significantly improving the diagnostic sensitivity, specificity, and accuracy of MD.

  20. Pseudo-acute myocardial infarction due to transient apical ventricular dysfunction syndrome (Takotsubo syndrome).

    Science.gov (United States)

    Maciel, Bruno Araújo; Cidrão, Alan Alves de Lima; Sousa, Italo Bruno Dos Santos; Ferreira, José Adailson da Silva; Messias Neto, Valdevino Pedro

    2013-03-01

    Takotsubo syndrome is characterized by predominantly medial-apical transient left ventricular dysfunction, which is typically triggered by physical or emotional stress. The present article reports the case of a 61-year-old female patient presenting with dizziness, excessive sweating, and sudden state of ill feeling following an episode involving intense emotional stress. The physical examination and electrocardiogram were normal upon admission, but the troponin I and creatine kinase-MB concentrations were increased. Acute myocardial infarction without ST segment elevation was suspected, and coronary angiography was immediately performed, which showed severe diffuse left ventricular hypokinesia, medial-apical systolic ballooning, and a lack of significant coronary injury. The patient was referred to the intensive care unit and was successfully treated with supportive therapy. As this case shows, Takotsubo syndrome might simulate the clinical manifestations of acute myocardial infarction, and coronary angiography is necessary to distinguish between both myocardial infarction and myocardial infarction in the acute stage. The present patient progressed with spontaneous resolution of the ventricular dysfunction without any sequelae.

  1. Screening for silent myocardial ischemia caseof diabetics : interest of myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Bahri, Haifa

    2007-01-01

    Silent myocardial ischemia is a major cause of morbidity and mortality in diabetic patients. Its diagnosis by noninvasive means such as myocardial SPECT would improve the management of these patients. The purpose of this study is to assess the frequency of silent myocardial ischemia in asymptomatic diabetics and their evolution. As a result, the myocardial SPECT is a reliable tool for screening for silent myocardial ischemia in diabetic patients. Its prognostic value allows to stratify the cardiac risk and guide therapeutic management. Its integration into a screening strategy in Tunisia seems limited by its low availability and cost. The latter could be reduced by better patient selection.

  2. Acute myocardial infarction

    International Nuclear Information System (INIS)

    RISCHPLER, Christoph

    2016-01-01

    Inflammatory processes after myocardial infarction have gained major interest in recent cardiovascular research. It is believed that not only the degree of cell recruitment to the heart plays a pivotal role in the quality of wound healing after myocardial infarction, but also the balance between different types or even subtypes of cells. It is also this balance which is thought to control key processes in tissue repair, such as apoptosis and neoangiogenesis. In this paper, we aim to review imaging strategies (with a special focus on nuclear molecular imaging strategies) that target cells and processes involved in postischemic inflammation and that have a high potential to be translated into clinic or that are already being used and evaluated in humans.

  3. Gamma-ray spectrometer system with high efficiency and high resolution

    International Nuclear Information System (INIS)

    Moss, C.E.; Bernard, W.; Dowdy, E.J.; Garcia, C.; Lucas, M.C.; Pratt, J.C.

    1983-01-01

    Our gamma-ray spectrometer system, designed for field use, offers high efficiency and high resolution for safeguards applications. The system consists of three 40% high-purity germanium detectors and a LeCroy 3500 data acquisition system that calculates a composite spectrum for the three detectors. The LeCroy 3500 mainframe can be operated remotely from the detector array with control exercised through modems and the telephone system. System performance with a mixed source of 125 Sb, 154 Eu, and 155 Eu confirms the expected efficiency of 120% with the overall resolution showing little degradation over that of the worst detector

  4. Radioiodinated tracers for myocardial imaging

    International Nuclear Information System (INIS)

    Kulkarni, P.V.; Corbett, J.R.

    1990-01-01

    Recent advances in the efficient production of high purity radioiodine (123I) and new efficient radiolabeling techniques have allowed the development of new classes of cardiovascular radiopharmaceuticals. These include 123I-labeled fatty acids to assess myocardial metabolism, 123I-metaiodobenzylguanidine (MIBG) for myocardial neuronal activity, labeled monoclonal antibodies for myocardial necrosis, and labeled lipoproteins for receptor concentration. 123I-labeled fatty acids and MIBG are under clinical investigation with encouraging results. 123I- and 111In-labeled fragments of monoclonal antibodies to myosin have been used for imaging myocardial necrosis in humans. The development of radiotracers for imaging of cholinergic and adrenergic receptors is still in the experimental stage. Recent advances in imaging instrumentation and radiopharmaceuticals have resulted in cardiac imaging applications beyond blood pool ventriculography, perfusion, and infarct-avid imaging. Developments of radioiodine (123I)-labeled agents promise to play an important role in the assessment of myocardial metabolism, neuronal activity, and receptor concentration. The chemistry of iodine is well defined compared with that of 99mTc; therefore, iodine isotopes are well suited for labeling biologically important molecules. Among the iodine isotopes, 123I has nearly ideal nuclear properties for nuclear medical applications with a 13.3-hour half-life (T1/2) and 159 keV gamma emission (83%). Despite the nearly ideal chemical and nuclear properties of 123I, the widespread application of 123I-based radiopharmaceuticals in clinical practice has been limited by high production costs (123I is produced in a cyclotron), relatively limited availability, and the presence of undesirable radionuclidic impurities (124I, T1/2 = 4.2 days; 125I, T1/2 = 60 days; 126I, T1/2 = 13.1 days). 77 references

  5. High resolution metric imaging payload

    Science.gov (United States)

    Delclaud, Y.

    2017-11-01

    Alcatel Space Industries has become Europe's leader in the field of high and very high resolution optical payloads, in the frame work of earth observation system able to provide military government with metric images from space. This leadership allowed ALCATEL to propose for the export market, within a French collaboration frame, a complete space based system for metric observation.

  6. High-resolution X-ray diffraction studies of multilayers

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Hornstrup, Allan; Schnopper, H. W.

    1988-01-01

    High-resolution X-ray diffraction studies of the perfection of state-of-the-art multilayers are presented. Data were obtained using a triple-axis perfect-crystal X-ray diffractometer. Measurements reveal large-scale figure errors in the substrate. A high-resolution triple-axis set up is required...

  7. Isotope specific resolution recovery image reconstruction in high resolution PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kotasidis, Fotis A. [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva, Switzerland and Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, M20 3LJ, Manchester (United Kingdom); Angelis, Georgios I. [Faculty of Health Sciences, Brain and Mind Research Institute, University of Sydney, NSW 2006, Sydney (Australia); Anton-Rodriguez, Jose; Matthews, Julian C. [Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, Manchester M20 3LJ (United Kingdom); Reader, Andrew J. [Montreal Neurological Institute, McGill University, Montreal QC H3A 2B4, Canada and Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King' s College London, St. Thomas’ Hospital, London SE1 7EH (United Kingdom); Zaidi, Habib [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva (Switzerland); Geneva Neuroscience Centre, Geneva University, CH-1205 Geneva (Switzerland); Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, PO Box 30 001, Groningen 9700 RB (Netherlands)

    2014-05-15

    Purpose: Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measurements. As such, non-optimal PSF models that do not correspond to those needed for the data to be reconstructed are used within resolution modeling (RM) image reconstruction, usually underestimating the true PSF owing to the difference in positron range. In high resolution brain and preclinical imaging, this effect is of particular importance since the PSFs become more positron range limited and isotope-specific PSFs can help maximize the performance benefit from using resolution recovery image reconstruction algorithms. Methods: In this work, the authors used a printing technique to simultaneously measure multiple point sources on the High Resolution Research Tomograph (HRRT), and the authors demonstrated the feasibility of deriving isotope-dependent system matrices from fluorine-18 and carbon-11 point sources. Furthermore, the authors evaluated the impact of incorporating them within RM image reconstruction, using carbon-11 phantom and clinical datasets on the HRRT. Results: The results obtained using these two isotopes illustrate that even small differences in positron range can result in different PSF maps, leading to further improvements in contrast recovery when used in image reconstruction. The difference is more pronounced in the centre of the field-of-view where the full width at half maximum (FWHM) from the positron range has a larger contribution to the overall FWHM compared to the edge where the parallax error dominates the overall FWHM. Conclusions: Based on the proposed methodology, measured isotope-specific and spatially variant PSFs can be reliably derived and used for improved spatial resolution and variance performance in resolution

  8. Isotope specific resolution recovery image reconstruction in high resolution PET imaging

    International Nuclear Information System (INIS)

    Kotasidis, Fotis A.; Angelis, Georgios I.; Anton-Rodriguez, Jose; Matthews, Julian C.; Reader, Andrew J.; Zaidi, Habib

    2014-01-01

    Purpose: Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measurements. As such, non-optimal PSF models that do not correspond to those needed for the data to be reconstructed are used within resolution modeling (RM) image reconstruction, usually underestimating the true PSF owing to the difference in positron range. In high resolution brain and preclinical imaging, this effect is of particular importance since the PSFs become more positron range limited and isotope-specific PSFs can help maximize the performance benefit from using resolution recovery image reconstruction algorithms. Methods: In this work, the authors used a printing technique to simultaneously measure multiple point sources on the High Resolution Research Tomograph (HRRT), and the authors demonstrated the feasibility of deriving isotope-dependent system matrices from fluorine-18 and carbon-11 point sources. Furthermore, the authors evaluated the impact of incorporating them within RM image reconstruction, using carbon-11 phantom and clinical datasets on the HRRT. Results: The results obtained using these two isotopes illustrate that even small differences in positron range can result in different PSF maps, leading to further improvements in contrast recovery when used in image reconstruction. The difference is more pronounced in the centre of the field-of-view where the full width at half maximum (FWHM) from the positron range has a larger contribution to the overall FWHM compared to the edge where the parallax error dominates the overall FWHM. Conclusions: Based on the proposed methodology, measured isotope-specific and spatially variant PSFs can be reliably derived and used for improved spatial resolution and variance performance in resolution

  9. Isotope specific resolution recovery image reconstruction in high resolution PET imaging.

    Science.gov (United States)

    Kotasidis, Fotis A; Angelis, Georgios I; Anton-Rodriguez, Jose; Matthews, Julian C; Reader, Andrew J; Zaidi, Habib

    2014-05-01

    Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measurements. As such, non-optimal PSF models that do not correspond to those needed for the data to be reconstructed are used within resolution modeling (RM) image reconstruction, usually underestimating the true PSF owing to the difference in positron range. In high resolution brain and preclinical imaging, this effect is of particular importance since the PSFs become more positron range limited and isotope-specific PSFs can help maximize the performance benefit from using resolution recovery image reconstruction algorithms. In this work, the authors used a printing technique to simultaneously measure multiple point sources on the High Resolution Research Tomograph (HRRT), and the authors demonstrated the feasibility of deriving isotope-dependent system matrices from fluorine-18 and carbon-11 point sources. Furthermore, the authors evaluated the impact of incorporating them within RM image reconstruction, using carbon-11 phantom and clinical datasets on the HRRT. The results obtained using these two isotopes illustrate that even small differences in positron range can result in different PSF maps, leading to further improvements in contrast recovery when used in image reconstruction. The difference is more pronounced in the centre of the field-of-view where the full width at half maximum (FWHM) from the positron range has a larger contribution to the overall FWHM compared to the edge where the parallax error dominates the overall FWHM. Based on the proposed methodology, measured isotope-specific and spatially variant PSFs can be reliably derived and used for improved spatial resolution and variance performance in resolution recovery image reconstruction. The

  10. Periodontitis and myocardial hypertrophy.

    Science.gov (United States)

    Suzuki, Jun-Ichi; Sato, Hiroki; Kaneko, Makoto; Yoshida, Asuka; Aoyama, Norio; Akimoto, Shouta; Wakayama, Kouji; Kumagai, Hidetoshi; Ikeda, Yuichi; Akazawa, Hiroshi; Izumi, Yuichi; Isobe, Mitsuaki; Komuro, Issei

    2017-04-01

    There is a deep relationship between cardiovascular disease and periodontitis. It has been reported that myocardial hypertrophy may be affected by periodontitis in clinical settings. Although these clinical observations had some study limitations, they strongly suggest a direct association between severity of periodontitis and left ventricular hypertrophy. However, the detailed mechanisms between myocardial hypertrophy and periodontitis have not yet been elucidated. Recently, we demonstrated that periodontal bacteria infection is closely related to myocardial hypertrophy. In murine transverse aortic constriction models, a periodontal pathogen, Aggregatibacter actinomycetemcomitans markedly enhanced cardiac hypertrophy with matrix metalloproteinase-2 activation, while another pathogen Porphyromonas gingivalis (P.g.) did not accelerate these pathological changes. In the isoproterenol-induced myocardial hypertrophy model, P.g. induced myocardial hypertrophy through Toll-like receptor-2 signaling. From our results and other reports, regulation of chronic inflammation induced by periodontitis may have a key role in the treatment of myocardial hypertrophy. In this article, we review the pathophysiological mechanism between myocardial hypertrophy and periodontitis.

  11. Dynamic CT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Caruso, Damiano; Eid, Marwen; Schoepf, U. Joseph; Jin, Kwang Nam; Varga-Szemes, Akos; Tesche, Christian; Mangold, Stefanie

    2016-01-01

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  12. Dynamic CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncological and Pathological Sciences, University of Rome “Sapienza”, Latina (Italy); Eid, Marwen [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Mangold, Stefanie [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen (Germany); and others

    2016-10-15

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  13. Scalable Algorithms for Large High-Resolution Terrain Data

    DEFF Research Database (Denmark)

    Mølhave, Thomas; Agarwal, Pankaj K.; Arge, Lars Allan

    2010-01-01

    In this paper we demonstrate that the technology required to perform typical GIS computations on very large high-resolution terrain models has matured enough to be ready for use by practitioners. We also demonstrate the impact that high-resolution data has on common problems. To our knowledge, so...

  14. High resolution NMR imaging using a high field yokeless permanent magnet.

    Science.gov (United States)

    Kose, Katsumi; Haishi, Tomoyuki

    2011-01-01

    We measured the homogeneity and stability of the magnetic field of a high field (about 1.04 tesla) yokeless permanent magnet with 40-mm gap for high resolution nuclear magnetic resonance (NMR) imaging. Homogeneity was evaluated using a 3-dimensional (3D) lattice phantom and 3D spin-echo imaging sequences. In the central sphere (20-mm diameter), peak-to-peak magnetic field inhomogeneity was about 60 ppm, and the root-mean-square was 8 ppm. We measured room temperature, magnet temperature, and NMR frequency of the magnet simultaneously every minute for about 68 hours with and without the thermal insulator of the magnet. A simple mathematical model described the magnet's thermal property. Based on magnet performance, we performed high resolution (up to [20 µm](2)) imaging with internal NMR lock sequences of several biological samples. Our results demonstrated the usefulness of the high field small yokeless permanent magnet for high resolution NMR imaging.

  15. High resolution NMR imaging using a high field yokeless permanent magnet

    International Nuclear Information System (INIS)

    Kose, Katsumi; Haishi, Tomoyuki

    2011-01-01

    We measured the homogeneity and stability of the magnetic field of a high field (about 1.04 tesla) yokeless permanent magnet with 40-mm gap for high resolution nuclear magnetic resonance (NMR) imaging. Homogeneity was evaluated using a 3-dimensional (3D) lattice phantom and 3D spin-echo imaging sequences. In the central sphere (20-mm diameter), peak-to-peak magnetic field inhomogeneity was about 60 ppm, and the root-mean-square was 8 ppm. We measured room temperature, magnet temperature, and NMR frequency of the magnet simultaneously every minute for about 68 hours with and without the thermal insulator of the magnet. A simple mathematical model described the magnet's thermal property. Based on magnet performance, we performed high resolution (up to [20 μm] 2 ) imaging with internal NMR lock sequences of several biological samples. Our results demonstrated the usefulness of the high field small yokeless permanent magnet for high resolution NMR imaging. (author)

  16. The clinical application value of myocardial perfusion imaging in evaluating coronary artery myocardial bridge patients with symptoms

    International Nuclear Information System (INIS)

    Wang Yuetao; Fu Ning; Ding Xuemei; Lu Cunzhi; Zhu Feng; Wang Guanmin; Huang Yijie; Wang Linguang

    2008-01-01

    Objective: Myocardial bridge is a common inborn coronary artery anomaly, myocardial bridge may be associated with myocardial ischemia. Only a few patients with coronary artery myocardial bridge were evaluated with nuclear medicine techniques. The aim of this study was to investigate the role of nuclear cardiology with myocardial perfusion technique in symptomatic myocardial bridge patients. Methods Nineteen myocardial bridge patients with the symptoms of chest pain and chest distress were analyzed retrospectively. 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion images (both exercise and rest) were performed in all. Imaging results were compared with the results of movement electrocardiogram (ECG) and coronary arteriography. The t test or χ 2 test was used to statistically analyze the data with Stata 7.0 software. Results: Of the 19 patients, 18 patients had myocardial bridge locating at the left anterior descending artery, 1 patient at the left anterior descending and left circumflex artery, the mean angiographic systolic occlusion within the myocardial bridge was (65.4 ± 22.1)%. Of these 19 patients, Exercise-rest 99 Tc m -MIBI myocardial perfusion imaging defined positive myocardial ischemia in 10 and negative in 9 patients. Of the 10 patients with 99 Tc m -MIBI myocardial perfusion imaging defined myocardial ischemia, 8 had reversible radioactive defect of partial anterior wall and (or) apex, 1 had reversible defect of post lateral wall and post septal wall, and 1 had reversible defect of inferior wall. The positive predictive value of myocardial perfusion imaging was 52.6% (10/19), which was higher than movement ECG [21.1% (4/19), χ 2 = 4.07, P 99 Tc m -MIBI myocardial periusion imaging defined myocardial ischemia. Six cases with Grade II stenosis, two were 99 Tc m -MIBI myocardial perfusion imaging defined myocardial ischemia. Eight cases with Grade III stenosis, seven were 99 Tc m -MIBI myocardial perfusion imaging defined myocardial

  17. Progress in high-resolution x-ray holographic microscopy

    International Nuclear Information System (INIS)

    Jacobsen, C.; Kirz, J.; Howells, M.; McQuaid, K.; Rothman, S.; Feder, R.; Sayre, D.

    1987-07-01

    Among the various types of x-ray microscopes that have been demonstrated, the holographic microscope has had the largest gap between promise and performance. The difficulties of fabricating x-ray optical elements have led some to view holography as the most attractive method for obtaining the ultimate in high resolution x-ray micrographs; however, we know of no investigations prior to 1987 that clearly demonstrated submicron resolution in reconstructed images. Previous efforts suffered from problems such as limited resolution and dynamic range in the recording media, low coherent x-ray flux, and aberrations and diffraction limits in visible light reconstruction. We have addressed the recording limitations through the use of an undulator x-ray source and high-resolution photoresist recording media. For improved results in the readout and reconstruction steps, we have employed metal shadowing and transmission electron microscopy, along with numerical reconstruction techniques. We believe that this approach will allow holography to emerge as a practical method of high-resolution x-ray microscopy. 30 refs., 4 figs

  18. Progress in high-resolution x-ray holographic microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, C.; Kirz, J.; Howells, M.; McQuaid, K.; Rothman, S.; Feder, R.; Sayre, D.

    1987-07-01

    Among the various types of x-ray microscopes that have been demonstrated, the holographic microscope has had the largest gap between promise and performance. The difficulties of fabricating x-ray optical elements have led some to view holography as the most attractive method for obtaining the ultimate in high resolution x-ray micrographs; however, we know of no investigations prior to 1987 that clearly demonstrated submicron resolution in reconstructed images. Previous efforts suffered from problems such as limited resolution and dynamic range in the recording media, low coherent x-ray flux, and aberrations and diffraction limits in visible light reconstruction. We have addressed the recording limitations through the use of an undulator x-ray source and high-resolution photoresist recording media. For improved results in the readout and reconstruction steps, we have employed metal shadowing and transmission electron microscopy, along with numerical reconstruction techniques. We believe that this approach will allow holography to emerge as a practical method of high-resolution x-ray microscopy. 30 refs., 4 figs.

  19. High-resolution spectroscopy of gases for industrial applications

    DEFF Research Database (Denmark)

    Fateev, Alexander; Clausen, Sønnik

    High-resolution spectroscopy of gases is a powerful technique which has various fundamental and practical applications: in situ simultaneous measurements of gas temperature and gas composition, radiative transfer modeling, validation of existing and developing of new databases and etc. Existing...... databases (e.g. HITRAN, HITEMP or CDSD) can normally be used for absorption spectra calculations at limited temperature/pressure ranges. Therefore experimental measurements of absorption/transmission spectra gases (e.g. CO2, H2O or SO2) at high-resolution and elevated temperatures are essential both...... for analysis of complex experimental data and further development of the databases. High-temperature gas cell facilities available at DTU Chemical Engineering are presented and described. The gas cells and high-resolution spectrometers allow us to perform high-quality reference measurements of gases relevant...

  20. Clinical Characteristics and Outcomes of Patients with Myocardial Infarction, Myocardial Injury, and Nonelevated Troponins

    DEFF Research Database (Denmark)

    Sarkisian, Laura; Saaby, Lotte; Poulsen, Tina S

    2016-01-01

    BACKGROUND: Cardiac troponins have emerged as the preferred biomarkers for detecting myocardial necrosis and diagnosing myocardial infarction. However, current cardiac troponin assays do not discriminate between ischemic and nonischemic causes of myocardial cell death. Thus, when an increased...... troponin value is encountered in the absence of obvious myocardial ischemia, a careful search for other clinical conditions is crucial. METHODS: In 2010 to 2011, we prospectively studied hospitalized patients who had cardiac troponin I measured on clinical indication. An acute myocardial infarction...... was diagnosed in cases of a cardiac troponin I increase or decrease pattern with at least 1 value >30 ng/L (99th percentile) together with myocardial ischemia. Myocardial injury was defined as cardiac troponin I values >30 ng/L, but without signs or symptoms indicating overt cardiac ischemia. Patients with peak...

  1. Towards high-resolution positron emission tomography for small volumes

    International Nuclear Information System (INIS)

    McKee, B.T.A.

    1982-01-01

    Some arguments are made regarding the medical usefulness of high spatial resolution in positron imaging, even if limited to small imaged volumes. Then the intrinsic limitations to spatial resolution in positron imaging are discussed. The project to build a small-volume, high resolution animal research prototype (SHARP) positron imaging system is described. The components of the system, particularly the detectors, are presented and brief mention is made of data acquisition and image reconstruction methods. Finally, some preliminary imaging results are presented; a pair of isolated point sources and 18 F in the bones of a rabbit. Although the detector system is not fully completed, these first results indicate that the goals of high sensitivity and high resolution (4 mm) have been realized. (Auth.)

  2. Myocardial infarction in Swedish subway drivers.

    Science.gov (United States)

    Bigert, Carolina; Klerdal, Kristina; Hammar, Niklas; Gustavsson, Per

    2007-08-01

    Particulate matter in urban air is associated with the risk of myocardial infarction in the general population. Very high levels of airborne particles have been detected in the subway system of Stockholm, as well as in several other large cities. This situation has caused concern for negative health effects among subway staff. The aim of this study was to investigate whether there is an increased incidence of myocardial infarction among subway drivers. Data from a population-based case-control study of men aged 40-69 in Stockholm County in 1976-1996 were used. The study included all first events of myocardial infarction in registers of hospital discharges and deaths. The controls were selected randomly from the general population. National censuses were used for information on occupation. Altogether, 22 311 cases and 131 496 controls were included. Among these, 54 cases and 250 controls had worked as subway drivers. The relative risk of myocardial infarction among subway drivers was not increased. It was 0.92 [95% confidence interval (95% CI) 0.68-1.25] when the subway drivers were compared with other manual workers and 1.06 (95% CI 0.78-1.43) when the subway drivers were compared with all other gainfully employed men. Subgroup analyses indicated no influence on the risk of myocardial infarction from the duration of employment, latency time, or time since employment stopped. Subway drivers in Stockholm do not have a higher incidence of myocardial infarction than other employed persons.

  3. Investigation of [18F]2-fluoro-2-deoxyglucose for the measure of myocardial glucose metabolism

    International Nuclear Information System (INIS)

    Phelps, M.E.; Hoffman, E.J.; Selin, C.; Huang, S.C.; Robinson, G.; MacDonald, N.; Schelbert, H.; Kuhl, D.E.

    1978-01-01

    Fluorine-18-labeled 2-deoxyglucose (FDG) was studied as a glucose analog for the measure of myocardial glucose metabolism. Myocardial uptake and retention, blood clearance, species dependence (dog, monkey, man), and effect of diet on uptake were investigated. Normal myocardial uptake of FDG was 3 to 4% of injected dose in dog and monkey, and 1 to 4% in man, compared with brain uptakes of 1.5 to 3% in dog, 5 to 6% in monkey, and 4 to 8% in man. The myocardial metabolic rate (MR) for glucose in the nonfasting (glycolytic) state was 2.8 times that in the fasting (ketogenic) state. Human subjects showed higher myocardial uptake after a normal meal than after a meal containing mostly free fatty acids (FFA). Blood clearance was rapid with initial clearance t/sub 1/2/ of 0.2 to 0.3 min, followed by a t/sub 1/2/ of 8.4 +- 1.2 min in dog and 11.6 +- 1.1 min in man. A small third component had half-times of 59 +- 10 min and 88 +- 4 min in dog and man, respectively. With the ECAT positron tomograph, high image-contrast ratios were found between heart and blood (dog 3.5/1, man 14/1), heart and lung (dog 9/1, man 20/1), and heart and liver (dog 15/1, man 10/1). The FDG was taken up rapidly by the myocardium without any significant tissue clearance over a 4-hr period. The FDG exhibited excellent imaging properties. Average counting rates of 12K, 20K, and 40K c/min-mCi injected are obtained in human subjects with high, medium, and low resolutions of the ECAT tomograph. Determination of glucose and FFA MR in vivo with EACT provides a method for investigation and assessment of changing aerobic and anaerobic metabolic rates in ischemic heart disease in man

  4. High-resolution X-ray crystal structure of bovine H-protein using the high-pressure cryocooling method

    International Nuclear Information System (INIS)

    Higashiura, Akifumi; Ohta, Kazunori; Masaki, Mika; Sato, Masaru; Inaka, Koji; Tanaka, Hiroaki; Nakagawa, Atsushi

    2013-01-01

    Using the high-pressure cryocooling method, the high-resolution X-ray crystal structure of bovine H-protein was determined at 0.86 Å resolution. This is the first ultra-high-resolution structure obtained from a high-pressure cryocooled crystal. Recently, many technical improvements in macromolecular X-ray crystallography have increased the number of structures deposited in the Protein Data Bank and improved the resolution limit of protein structures. Almost all high-resolution structures have been determined using a synchrotron radiation source in conjunction with cryocooling techniques, which are required in order to minimize radiation damage. However, optimization of cryoprotectant conditions is a time-consuming and difficult step. To overcome this problem, the high-pressure cryocooling method was developed (Kim et al., 2005 ▶) and successfully applied to many protein-structure analyses. In this report, using the high-pressure cryocooling method, the X-ray crystal structure of bovine H-protein was determined at 0.86 Å resolution. Structural comparisons between high- and ambient-pressure cryocooled crystals at ultra-high resolution illustrate the versatility of this technique. This is the first ultra-high-resolution X-ray structure obtained using the high-pressure cryocooling method

  5. High resolution drift chambers

    International Nuclear Information System (INIS)

    Va'vra, J.

    1985-07-01

    High precision drift chambers capable of achieving less than or equal to 50 μm resolutions are discussed. In particular, we compare so called cool and hot gases, various charge collection geometries, several timing techniques and we also discuss some systematic problems. We also present what we would consider an ''ultimate'' design of the vertex chamber. 50 refs., 36 figs., 6 tabs

  6. Abnormal myocardial capillary density in apical hypertrophic cardiomyopathy can be assessed by myocardial contrast echocardiography

    International Nuclear Information System (INIS)

    Moon, Jeonggeun; Cho, In-Jeong; Shim, Chi-Young; Ha, Jong-Won; Jang, Yangsoo; Chung, Namsik; Rim, Se-Joong

    2010-01-01

    Myocardial ischemia and dysfunction can occur in hypertrophic cardiomyopathy (HCM) because of the high muscle-to-blood ratio, even without significant coronary artery disease. Microbubbles reside only in the intravascular space and myocardial video-intensity during systole results mostly from microbubbles within capillaries. The hypothesis explored in the present study was that an abnormal capillary density in apical HCM (ApHCM) can be demonstrated using myocardial contrast echocardiography (MCE). The 56 patients were investigated (31 males, age 58±9 years; 33 ApHCM, 9 hypertensive left ventricular hypertrophy [LVH], 14 controls). MCE was performed with low-mechanical-index power modulation imaging. Tissue Doppler imaging to assess myocardial contractile function was obtained at the mitral annulus (S'), and 99m Tc-MIBI single photon emission computed tomography (SPECT) was also performed. All ApHCM patients exhibited perfusion defects at the hypertrophied segments in the systolic phase during MCE, whereas SPECT showed normal or rather increased perfusion at those sites. The cyclic variation of video-intensity was exaggerated in ApHCM when compared with the LVH or control group (% of [systolic video-intensity]/[diastolic video-intensity]: 33.0±12.3%, 88.3±19.2% and 79.4±13.9%, respectively [P<0.05]). Concurrently, MCE cyclic variation and perfusion defect size were related to decreased S' (P<0.05 for all). A perfusion defect at the hypertrophied segment, representing abnormal myocardial capillary density, was observed in ApHCM patients during MCE. The extent of MCE cyclic variation and the perfusion defect size both correlate with decreased myocardial contractile property in ApHCM. (author)

  7. High resolution neutron spectroscopy for helium isotopes

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; Klages, H.O.; Schmalz, G.; Haesner, B.H.; Kecskemeti, J.; Schwarz, P.; Wilczynski, J.

    1992-01-01

    A high resolution fast neutron time-of-flight spectrometer is described, neutron time-of-flight spectra are taken using a specially designed TDC in connection to an on-line computer. The high time-of-flight resolution of 5 ps/m enabled the study of the total cross section of 4 He for neutrons near the 3/2 + resonance in the 5 He nucleus. The resonance parameters were determined by a single level Breit-Winger fit to the data. (orig.)

  8. A high-resolution regional reanalysis for Europe

    Science.gov (United States)

    Ohlwein, C.

    2015-12-01

    Reanalyses gain more and more importance as a source of meteorological information for many purposes and applications. Several global reanalyses projects (e.g., ERA, MERRA, CSFR, JMA9) produce and verify these data sets to provide time series as long as possible combined with a high data quality. Due to a spatial resolution down to 50-70km and 3-hourly temporal output, they are not suitable for small scale problems (e.g., regional climate assessment, meso-scale NWP verification, input for subsequent models such as river runoff simulations). The implementation of regional reanalyses based on a limited area model along with a data assimilation scheme is able to generate reanalysis data sets with high spatio-temporal resolution. Within the Hans-Ertel-Centre for Weather Research (HErZ), the climate monitoring branch concentrates efforts on the assessment and analysis of regional climate in Germany and Europe. In joint cooperation with DWD (German Meteorological Service), a high-resolution reanalysis system based on the COSMO model has been developed. The regional reanalysis for Europe matches the domain of the CORDEX EURO-11 specifications, albeit at a higher spatial resolution, i.e., 0.055° (6km) instead of 0.11° (12km) and comprises the assimilation of observational data using the existing nudging scheme of COSMO complemented by a special soil moisture analysis with boundary conditions provided by ERA-Interim data. The reanalysis data set covers the past 20 years. Extensive evaluation of the reanalysis is performed using independent observations with special emphasis on precipitation and high-impact weather situations indicating a better representation of small scale variability. Further, the evaluation shows an added value of the regional reanalysis with respect to the forcing ERA Interim reanalysis and compared to a pure high-resolution dynamical downscaling approach without data assimilation.

  9. Effect of streptozotocin-induced diabetes on myocardial blood flow reserve assessed by myocardial contrast echocardiography in rats

    Directory of Open Access Journals (Sweden)

    Weytjens Caroline

    2008-09-01

    Full Text Available Abstract The role of structural and functional abnormalities of small vessels in diabetes cardiomyopathy remains unclear. Myocardial contrast echocardiography allows the quantification of myocardial blood flow at rest and during dipyridamole infusion. The aim of the study was to determine the myocardial blood flow reserve in normal rats compared with Streptozotocin-induced diabetic rats using contrast echocardiography. Methods We prospectively studied 40 Wistar rats. Diabetes was induced by intravenous streptozotocin in 20 rats. All rats underwent baseline and stress (dipyridamole: 20 mg/kg high power intermittent imaging in short axis view under anaesthesia baseline and after six months. Myocardial blood flow was determined and compared at rest and after dipyridamole in both populations. The myocardial blood flow reserve was calculated and compared in the 2 groups. Parameters of left ventricular function were determined from the M-mode tracings and histological examination was performed in all rats at the end of the study. Results At six months, myocardial blood flow reserve was significantly lower in diabetic rats compared to controls (3.09 ± 0.98 vs. 1.28 ± 0.67 ml min-1 g-1; p Conclusion In this animal study, diabetes induced a functional alteration of the coronary microcirculation, as demonstrated by contrast echocardiography, a decrease in capillary density and of the cardiac systolic function. These findings may offer new insights into the underlying mechanisms of diabetes cardiomyopathy.

  10. High-resolution in vivo imaging of the cross-sectional deformations of contracting embryonic heart loops using optical coherence tomography

    DEFF Research Database (Denmark)

    Männer, J.; Thrane, Lars; Norozi, K.

    2008-01-01

    The embryonic heart tube consists of an outer myocardial tube, a middle layer of cardiac jelly, and an inner endocardial tube. It is said that tubular hearts pump the blood by peristaltoid contractions. The traditional concept of cardiac peristalsis sees the cyclic deformations of pulsating heart...... tubes as concentric narrowing and widening of tubes of circular cross-section. We have visualized the cross-sectional deformations of contracting embryonic hearts in chick embryos (HH-stages 9-17) using real-time high-resolution optical coherence tomography. Cardiac contractions are detected from HH...... of the endocardial tube is the consequence of an uneven distribution of the cardiac jelly. Our data show that the cyclic deformations of pulsating embryonic heart tubes run other than originally thought. There is evidence that heart tubes of elliptic cross-section might pump blood with a higher mechanical efficiency...

  11. Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Carrascosa, Patricia M., E-mail: investigacion@diagnosticomaipu.com.ar; Deviggiano, Alejandro; Capunay, Carlos; Campisi, Roxana; López Munain, Marina de; Vallejos, Javier; Tajer, Carlos; Rodriguez-Granillo, Gaston A.

    2015-04-15

    Highlights: •We evaluated myocardial perfusion by dual energy computed tomography (DECT). •We included patients with intermediate to high likelihood of coronary artery disease. •Stress myocardial perfusion by DECT had a reliable accuracy for the detection of ischemia. •Stress myocardial perfusion with DECT showed an incremental value over anatomical evaluation. •DECT imaging was associated to a significant reduction in radiation dose compared to SPECT. -- Abstract: Purpose: We sought to explore the diagnostic performance of dual energy computed tomography (DECT) for the evaluation of myocardial perfusion in patients with intermediate to high likelihood of coronary artery disease (CAD). Materials and methods: Consecutive patients with known or suspected CAD referred for myocardial perfusion imaging by single-photon emission computed tomography (SPECT) constituted the study population and were scanned using a DECT scanner equipped with gemstone detectors for spectral imaging, and a SPECT. The same pharmacological stress was used for both scans. Results: Twenty-five patients were prospectively included in the study protocol. The mean age was 63.4 ± 10.6 years. The total mean effective radiation dose was 7.5 ± 1.2 mSv with DECT and 8.2 ± 1.7 mSv with SPECT (p = 0.007). A total of 425 left ventricular segments were evaluated by DECT, showing a reliable accuracy for the detection of reversible perfusion defects [area under ROC curve (AUC) 0.84 (0.80–0.87)]. Furthermore, adding stress myocardial perfusion provided a significant incremental value over anatomical evaluation alone by computed tomography coronary angiography [AUC 0.70 (0.65–0.74), p = 0.003]. Conclusions: In this pilot investigation, stress myocardial perfusion by DECT demonstrated a significant incremental value over anatomical evaluation alone by CTCA for the detection of reversible perfusion defects.

  12. Automated data processing of high-resolution mass spectra

    DEFF Research Database (Denmark)

    Hansen, Michael Adsetts Edberg; Smedsgaard, Jørn

    of the massive amounts of data. We present an automated data processing method to quantitatively compare large numbers of spectra from the analysis of complex mixtures, exploiting the full quality of high-resolution mass spectra. By projecting all detected ions - within defined intervals on both the time...... infusion of crude extracts into the source taking advantage of the high sensitivity, high mass resolution and accuracy and the limited fragmentation. Unfortunately, there has not been a comparable development in the data processing techniques to fully exploit gain in high resolution and accuracy...... infusion analyses of crude extract to find the relationship between species from several species terverticillate Penicillium, and also that the ions responsible for the segregation can be identified. Furthermore the process can automate the process of detecting unique species and unique metabolites....

  13. [Interventional therapy of acute myocardial infarction].

    Science.gov (United States)

    Zahn, R; Zeymer, U

    2008-09-01

    Currently an acute myocardial infarction has to be differentiated into ST-elevation myocardial infarction (STEMI) or non ST-elevation myocardial infarction (NSTEMI). However, there exists another definition of acute coronary syndromes (ACS), which is more important in clinical practice, for all recommendations from the guidelines of the cardiac societies concerning the invasive strategies rely on this one. Here one has to differentiate an ACS with ST-elevation (STE-ACS = STEMI) from an ACS without ST-elevation (NSTE-ACS). The last one is further divided into an NSTE-ACS with or without high risk. In patients with an NSTE-ACS with high risk an early invasive strategy is recommended within 72 h after the diagnosis. In patients with an NSTE-ACS without high risk a more conservative approach can be pursued. In STE-ACS patients primary angioplasty is the reperfusion therapy of choice, if it can be performed in a timely fashion within 2 h after diagnosis at an interventional centre with experienced interventionalists and short "door-to-balloon" times. In Germany this goal is achievable almost everywhere. Therefore it is currently the most important task to establish local networks to reach this goal.

  14. Achieving sensitive, high-resolution laser spectroscopy at CRIS

    Energy Technology Data Exchange (ETDEWEB)

    Groote, R. P. de [Instituut voor Kern- en Stralingsfysica, KU Leuven (Belgium); Lynch, K. M., E-mail: kara.marie.lynch@cern.ch [EP Department, CERN, ISOLDE (Switzerland); Wilkins, S. G. [The University of Manchester, School of Physics and Astronomy (United Kingdom); Collaboration: the CRIS collaboration

    2017-11-15

    The Collinear Resonance Ionization Spectroscopy (CRIS) experiment, located at the ISOLDE facility, has recently performed high-resolution laser spectroscopy, with linewidths down to 20 MHz. In this article, we present the modifications to the beam line and the newly-installed laser systems that have made sensitive, high-resolution measurements possible. Highlights of recent experimental campaigns are presented.

  15. Clinical impact and predictors of complete ST segment resolution after primary percutaneous coronary intervention: A subanalysis of the ATLANTIC Trial.

    Science.gov (United States)

    Fabris, Enrico; van 't Hof, Arnoud; Hamm, Christian W; Lapostolle, Frédéric; Lassen, Jens F; Goodman, Shaun G; Ten Berg, Jurriën M; Bolognese, Leonardo; Cequier, Angel; Chettibi, Mohamed; Hammett, Christopher J; Huber, Kurt; Janzon, Magnus; Merkely, Béla; Storey, Robert F; Zeymer, Uwe; Cantor, Warren J; Tsatsaris, Anne; Kerneis, Mathieu; Diallo, Abdourahmane; Vicaut, Eric; Montalescot, Gilles

    2017-08-01

    In the ATLANTIC (Administration of Ticagrelor in the catheterization laboratory or in the Ambulance for New ST elevation myocardial Infarction to open the Coronary artery) trial the early use of aspirin, anticoagulation, and ticagrelor coupled with very short medical contact-to-balloon times represent good indicators of optimal treatment of ST-elevation myocardial infarction and an ideal setting to explore which factors may influence coronary reperfusion beyond a well-established pre-hospital system. This study sought to evaluate predictors of complete ST-segment resolution after percutaneous coronary intervention in ST-elevation myocardial infarction patients enrolled in the ATLANTIC trial. ST-segment analysis was performed on electrocardiograms recorded at the time of inclusion (pre-hospital electrocardiogram), and one hour after percutaneous coronary intervention (post-percutaneous coronary intervention electrocardiogram) by an independent core laboratory. Complete ST-segment resolution was defined as ≥70% ST-segment resolution. Complete ST-segment resolution occurred post-percutaneous coronary intervention in 54.9% ( n=800/1456) of patients and predicted lower 30-day composite major adverse cardiovascular and cerebrovascular events (odds ratio 0.35, 95% confidence interval 0.19-0.65; pST-segment resolution were the time from symptoms to pre-hospital electrocardiogram (odds ratio 0.91, 95% confidence interval 0.85-0.98; pST-segment resolution (odds ratio 1.22, 95% confidence interval 0.99-1.51; p=0.06). This study confirmed that post-percutaneous coronary intervention complete ST-segment resolution is a valid surrogate marker for cardiovascular clinical outcomes. In the current era of ST-elevation myocardial infarction reperfusion, patients' delay and diabetes mellitus are independent predictors of poor reperfusion and need specific attention in the future.

  16. An atlas of high-resolution IRAS maps on nearby galaxies

    Science.gov (United States)

    Rice, Walter

    1993-01-01

    An atlas of far-infrared IRAS maps with near 1 arcmin angular resolution of 30 optically large galaxies is presented. The high-resolution IRAS maps were produced with the Maximum Correlation Method (MCM) image construction and enhancement technique developed at IPAC. The MCM technique, which recovers the spatial information contained in the overlapping detector data samples of the IRAS all-sky survey scans, is outlined and tests to verify the structural reliability and photometric integrity of the high-resolution maps are presented. The infrared structure revealed in individual galaxies is discussed. The atlas complements the IRAS Nearby Galaxy High-Resolution Image Atlas, the high-resolution galaxy images encoded in FITS format, which is provided to the astronomical community as an IPAC product.

  17. Diagnostic value of exercise induced 18F-FDG myocardial metabolism scintigraphy in myocardial ischemia

    International Nuclear Information System (INIS)

    Shen Rui; He Zuoxiang; Shi Rongfang; Liu Xiujie; Tian Yueqin; Guo Feng; Wei Hongxing; Wu Yongjian; Qin Xuewen; Gao Runlin

    2006-01-01

    Objective: To evaluate the feasibility and diagnostic accuracy of exercise induced myocardial imaging with 18 F-fluorodeoxyglucose (FDG) in myocardial ischemia. Methods: Twenty-six patients with known or suspected coronary artery, disease (CAD) and with no prior myocardial infarction underwent simultaneous myocardial perfusion and metabolism imaging following intravenous injection of 99 Tc m -methoxy-isobutylisonitrile ( 99 Tc m -sestamibi) and 18 F-FDG at peak exercise. Subsequently rest perfusion imaging and coronary angiography (CAG) were performed in all patients. Exercise 18 F-FDG myocardial imaging was compared with 99 Tc m -sestamibi imaging and CAG. Results: In 22 patients with ≥50% narrowing over l coronary artery, 18 had perfusion abnormalities (sensitivity 82%), whereas 20 had abnormal myocardial 18 F-FDG uptake (sensitivity 91%, P>0.05). Patients with reversible (12 cases) or partial reversible (3 cases) perfusion abnormalities had increased myocardial 18 F-FDG uptake in abnormal perfusion segments. Compared with CAG, perfusion defect was seen in myocardial segments corresponding to 25 vascular territories of 51 vessels with ≥50% narrowing in 22 patients in 99 Tc m -sestamibi imaging (sensitivity 49%), whereas increased 18 F-FDG uptake was seen in 34 vascular territories (sensitivity 67%, P=0.008). Conclusions: Exercise induced myocardial ischemia can be imaged directly with 18 F-FDG. Combined exercise 18 F-FDG and 99 Tc m -sestamibi imaging provides a better assessment of exercise-induced myocardial ischemia as compared with exercise-rest perfusion imaging. (authors)

  18. Localization and quantification of acute myocardial infarction by myocardial perfusion tomographic imaging

    International Nuclear Information System (INIS)

    Lin Xiufang; Min Changgeng; Lin Zhihu; Ke Ruoyi

    1994-01-01

    The authors reported the result of the quantification and localization of 30 clinically confirmed acute myocardial infarction patients in comparison with that of ECG. A left ventricle model was used to correct the area calculated by the method of Bull's eye. The result indicated that the infarction area calculated by the corrected Bull's eye method correlated closely with that determined by the ECG QRS scoring method (r = 0.706, P<0.01). Myocardial infarctions of all 30 patients were detected by both ECG and myocardial perfusion tomographic imaging. The accuracy of localization of myocardial infarction by myocardial perfusion imaging was similar to that of ECG in the anterior wall, anterior septum, anterior lateral and inferior wall, but superior to that of ECG in the apex, posterior lateral, posterior septum, and posterior wall

  19. Development of high speed integrated circuit for very high resolution timing measurements

    International Nuclear Information System (INIS)

    Mester, Christian

    2009-10-01

    A multi-channel high-precision low-power time-to-digital converter application specific integrated circuit for high energy physics applications has been designed and implemented in a 130 nm CMOS process. To reach a target resolution of 24.4 ps, a novel delay element has been conceived. This nominal resolution has been experimentally verified with a prototype, with a minimum resolution of 19 ps. To further improve the resolution, a new interpolation scheme has been described. The ASIC has been designed to use a reference clock with the LHC bunch crossing frequency of 40 MHz and generate all required timing signals internally, to ease to use within the framework of an LHC upgrade. Special care has been taken to minimise the power consumption. (orig.)

  20. Development of high speed integrated circuit for very high resolution timing measurements

    Energy Technology Data Exchange (ETDEWEB)

    Mester, Christian

    2009-10-15

    A multi-channel high-precision low-power time-to-digital converter application specific integrated circuit for high energy physics applications has been designed and implemented in a 130 nm CMOS process. To reach a target resolution of 24.4 ps, a novel delay element has been conceived. This nominal resolution has been experimentally verified with a prototype, with a minimum resolution of 19 ps. To further improve the resolution, a new interpolation scheme has been described. The ASIC has been designed to use a reference clock with the LHC bunch crossing frequency of 40 MHz and generate all required timing signals internally, to ease to use within the framework of an LHC upgrade. Special care has been taken to minimise the power consumption. (orig.)

  1. Classification of myocardial infarction

    DEFF Research Database (Denmark)

    Saaby, Lotte; Poulsen, Tina Svenstrup; Hosbond, Susanne Elisabeth

    2013-01-01

    The classification of myocardial infarction into 5 types was introduced in 2007 as an important component of the universal definition. In contrast to the plaque rupture-related type 1 myocardial infarction, type 2 myocardial infarction is considered to be caused by an imbalance between demand...

  2. High-resolution MRI in detecting subareolar breast abscess.

    Science.gov (United States)

    Fu, Peifen; Kurihara, Yasuyuki; Kanemaki, Yoshihide; Okamoto, Kyoko; Nakajima, Yasuo; Fukuda, Mamoru; Maeda, Ichiro

    2007-06-01

    Because subareolar breast abscess has a high recurrence rate, a more effective imaging technique is needed to comprehensively visualize the lesions and guide surgery. We performed a high-resolution MRI technique using a microscopy coil to reveal the characteristics and extent of subareolar breast abscess. High-resolution MRI has potential diagnostic value in subareolar breast abscess. This technique can be used to guide surgery with the aim of reducing the recurrence rate.

  3. Direct Evidence that Myocardial Insulin Resistance following Myocardial Ischemia Contributes to Post-Ischemic Heart Failure

    Science.gov (United States)

    Fu, Feng; Zhao, Kun; Li, Jia; Xu, Jie; Zhang, Yuan; Liu, Chengfeng; Yang, Weidong; Gao, Chao; Li, Jun; Zhang, Haifeng; Li, Yan; Cui, Qin; Wang, Haichang; Tao, Ling; Wang, Jing; Quon, Michael J; Gao, Feng

    2015-01-01

    A close link between heart failure (HF) and systemic insulin resistance has been well documented, whereas myocardial insulin resistance and its association with HF are inadequately investigated. This study aims to determine the role of myocardial insulin resistance in ischemic HF and its underlying mechanisms. Male Sprague-Dawley rats subjected to myocardial infarction (MI) developed progressive left ventricular dilation with dysfunction and HF at 4 wk post-MI. Of note, myocardial insulin sensitivity was decreased as early as 1 wk after MI, which was accompanied by increased production of myocardial TNF-α. Overexpression of TNF-α in heart mimicked impaired insulin signaling and cardiac dysfunction leading to HF observed after MI. Treatment of rats with a specific TNF-α inhibitor improved myocardial insulin signaling post-MI. Insulin treatment given immediately following MI suppressed myocardial TNF-α production and improved cardiac insulin sensitivity and opposed cardiac dysfunction/remodeling. Moreover, tamoxifen-induced cardiomyocyte-specific insulin receptor knockout mice exhibited aggravated post-ischemic ventricular remodeling and dysfunction compared with controls. In conclusion, MI induces myocardial insulin resistance (without systemic insulin resistance) mediated partly by ischemia-induced myocardial TNF-α overproduction and promotes the development of HF. Our findings underscore the direct and essential role of myocardial insulin signaling in protection against post-ischemic HF. PMID:26659007

  4. Recent applications of gas chromatography with high-resolution mass spectrometry.

    Science.gov (United States)

    Špánik, Ivan; Machyňáková, Andrea

    2018-01-01

    Gas chromatography coupled to high-resolution mass spectrometry is a powerful analytical method that combines excellent separation power of gas chromatography with improved identification based on an accurate mass measurement. These features designate gas chromatography with high-resolution mass spectrometry as the first choice for identification and structure elucidation of unknown volatile and semi-volatile organic compounds. Gas chromatography with high-resolution mass spectrometry quantitative analyses was previously focused on the determination of dioxins and related compounds using magnetic sector type analyzers, a standing requirement of many international standards. The introduction of a quadrupole high-resolution time-of-flight mass analyzer broadened interest in this method and novel applications were developed, especially for multi-target screening purposes. This review is focused on the development and the most interesting applications of gas chromatography coupled to high-resolution mass spectrometry towards analysis of environmental matrices, biological fluids, and food safety since 2010. The main attention is paid to various approaches and applications of gas chromatography coupled to high-resolution mass spectrometry for non-target screening to identify contaminants and to characterize the chemical composition of environmental, food, and biological samples. The most interesting quantitative applications, where a significant contribution of gas chromatography with high-resolution mass spectrometry over the currently used methods is expected, will be discussed as well. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. The relationship between myocardial blood flow and myocardial viability after reperfusion. Myocardial viability assessed by 15O-water-PET

    International Nuclear Information System (INIS)

    Tsukagoshi, Joichi

    1994-01-01

    The purpose of this study was to examine the relationship between myocardial blood flow and myocardial viability in the ischemic canine myocardium after reperfusion. Transient ischemia was induced by 60-, 90-, and 180-minute occlusion of the left anterior descending coronary artery. Myocardial blood flow (MBF) was measured in the areas in which regional contractility was severely impaired (ehocardiographically akinetic or dyskinetic) in the early reperfusion period by 15 O-water positron emission tomography (PET) 12 hours and 4 weeks after reperfusion. An MBF ratio of ischemic to nonischemic regions 12 hours after reperfusion was inversely correlated with the amount of histologically determined tissue necrosis (r=-0.74). The regional contractility recovered 4 weeks later in the areas where an MBF ratio was 0.48 or greater, but did not recover in the areas with a lower MBF ratio. Thus, myocardial viability can be appropriately predicted in the early phase of myocardial perfusion by PET with 15 O-water even in the absence of metabolic imaging. (author)

  6. Myocardial Na,K-ATPase: Clinical aspects

    OpenAIRE

    Kjeldsen, Keld

    2003-01-01

    The specific binding of digitalis glycosides to Na,K-ATPase is used as a tool for Na,K-ATPase quantification with high accuracy and precision. In myocardial biopsies from patients with heart failure, total Na,K-ATPase concentration is decreased by around 40%; a correlation exists between a decrease in heart function and a decrease in Na,K-ATPase concentration. During digitalization, around 30% of remaining pumps are occupied by digoxin. Myocardial Na,K-ATPase is also influenced by other drugs...

  7. Tl myocardial SPECT demonstrates importance of collateral circulation in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Hattori, Fukunori

    1997-01-01

    The influence of collateral circulation on the preservation of myocardial viability and the efficacy of drug therapy and PTCA were evaluated by exercise 201 Tl myocardial SPECT before and after treatment. Thirty-five patients with a history of myocardial infarction resulting from total or subtotal obstruction of the responsible coronary artery were divided into four groups, according to the method of the treatment and the degree of collateral blood flow. Patients in groups A and B received drug therapy and displayed developed and undeveloped collateral circulation, respectively. Groups C and D received PTCA and displayed developed and undeveloped collateral circulation, respectively. Tl myocardial SPECT was performed before treatment to record the extent of redistribution to the occluded region, the degree of myocardial viability and the nature and extent of the ischemic lesion. In group A, myocardial perfusion improved, although redistribution remained in all cases, while in group B, 4 of 7 cases improved after drug therapy. In group C, myocardial perfusion improved in all cases, and redistribution disappeared in 7 of 12 cases. 5 of 6 cases improved in group D after PTCA. After drug therapy, the %Tl uptake in the infarcted region improved significantly in initial and delayed images of patients in group A. The differences in initial and delayed images in group B before and after drug therapy were not significant. In contrast, groups C and D both registered significant improvement in initial and delayed images after PTCA. The washout rate improved significantly in groups A, C and D after their respective treatments. These results suggest that developed collateral circulation helps to preserve myocardial viability in cases of myocardial infarction. Myocardial perfusion improved after drug therapy in cases with developed collateral circulation, and in patients with developed and undeveloped collateral circulation receiving PTCA. (K.H.)

  8. Detection of myocardial ischemia with myocardial perfusion SPECT in patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Seo, J. H.; Jeong, S. Y.; Bae, J. H.; Anh, B. C.; Lee, J.; Lee, K. B

    2004-01-01

    Diabetes mellitus(DM) is a critical disease associated with higher rates of cardiovascular morbidity and mortality. Atherosclerosis accounts for 65-80% of all deaths in diabetic patients and patients with DM are known to show high prevalence of coronary artery diseases(CAD). We evaluated the incidence of scintigraphic evidence of CAD in diabetic patients and results were compared with cardiovascular symptoms and clinical factors. 169 patients with DM(mean age 629years, 68 males) were referred for evaluation of CAD between Jan 2002 and Dec 2003. 101(60%) patients were with chest pain and 68(40%) were asymptomatic. Patients underwent exercise(n=6) or adenosine stress(n=163) SPECT myocardial perfusion imaging(MPI). Exclusion criteria included history of documented myocardial infarction, prior revascularization, clinically significant valvular heart disease, left-bundle branch block on rest ECG. We evaluated symptoms associated with cardiac problem and other clinical and laboratory data to reveal correlation with presence of CAD. MPI were assessed visually and semi-quantitatively with C-Equal program. Myocardial ischemia was detected in 52(31%) patients. Among them, 41 had 1-vessel and 9 had 2-vessel disease. In 52 patients with ischemia, 28(54%) were male and 24(46%) were female. 20/68(29%) asymptomatic and 32/101(32%) symptomatic patients had ischemia. Higher prevalence of neuropathy, hypertension, higher blood glucose level, HbA1c and CRP was noted in patients with myocardial ischemia. Serum levels of cholesterol and LDL was not significantly different between patients with ischemia and with normal MPI findings. Abnormal MPI findings were not related with gender and age. These results show a high prevalence of abnormal MPI results in diabetic patients regardless of symptoms. Screening stress MPI in diabetic patients should be indicated irrespective of symptoms, especially in patients with neuropathy, hypertension, higher level of blood glucose, or increased CRP

  9. Detection of myocardial ischemia with myocardial perfusion SPECT in patients with diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Seo, J. H.; Jeong, S. Y.; Bae, J. H.; Anh, B. C.; Lee, J.; Lee, K. B [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2004-07-01

    Diabetes mellitus(DM) is a critical disease associated with higher rates of cardiovascular morbidity and mortality. Atherosclerosis accounts for 65-80% of all deaths in diabetic patients and patients with DM are known to show high prevalence of coronary artery diseases(CAD). We evaluated the incidence of scintigraphic evidence of CAD in diabetic patients and results were compared with cardiovascular symptoms and clinical factors. 169 patients with DM(mean age 629years, 68 males) were referred for evaluation of CAD between Jan 2002 and Dec 2003. 101(60%) patients were with chest pain and 68(40%) were asymptomatic. Patients underwent exercise(n=6) or adenosine stress(n=163) SPECT myocardial perfusion imaging(MPI). Exclusion criteria included history of documented myocardial infarction, prior revascularization, clinically significant valvular heart disease, left-bundle branch block on rest ECG. We evaluated symptoms associated with cardiac problem and other clinical and laboratory data to reveal correlation with presence of CAD. MPI were assessed visually and semi-quantitatively with C-Equal program. Myocardial ischemia was detected in 52(31%) patients. Among them, 41 had 1-vessel and 9 had 2-vessel disease. In 52 patients with ischemia, 28(54%) were male and 24(46%) were female. 20/68(29%) asymptomatic and 32/101(32%) symptomatic patients had ischemia. Higher prevalence of neuropathy, hypertension, higher blood glucose level, HbA1c and CRP was noted in patients with myocardial ischemia. Serum levels of cholesterol and LDL was not significantly different between patients with ischemia and with normal MPI findings. Abnormal MPI findings were not related with gender and age. These results show a high prevalence of abnormal MPI results in diabetic patients regardless of symptoms. Screening stress MPI in diabetic patients should be indicated irrespective of symptoms, especially in patients with neuropathy, hypertension, higher level of blood glucose, or increased CRP.

  10. Myocardial uptake of cocaine and effects of cocaine on myocardial substrate utilization and perfusion in hypertensive rats

    Energy Technology Data Exchange (ETDEWEB)

    Som, P.; Wang, G.J. [Brookhaven National Lab., Upton, NY (United States); Oster, Z.H. [State Univ. of New York, Stony Brook, NY (United States); Knapp, F.F. Jr. [Oak Ridge National Lab., TN (United States); Yonekura, Y. [Kyoto Univ. (Japan). Faculty of Medicine; Fujibayashi, Y. [Kyoto Univ. (Japan). Hospital; Yamamoto, K. [Fukui Univ. (Japan). Medical School; Kubota, K. [Tohoku Univ., Sendai (Japan)

    1992-12-31

    Cocaine abuse is a problem causing world-wide concern and the number of deaths following cocaine use is increasing. Cardiovascular complications following cocaine include severe tachyarrythmias, pulmonary edema, myocardial infarction, and acute renal failure, which are major problems confronting emergency facilities. While the studies of cocaine effects on the brain have been given the most attention, it is clear that the effects of cocaine on the cardiovascular system are of great importance, given the increasing number of reports on sudden death and myocardial infarctions in young adults related to cocaine use. The precise mechanisms of cardiotoxic actions of cocaine are unclear. We investigated the whole-body distribution of C-14-labeled cocaine to determine the cocaine-binding sites, including blocking experiments to determine the nature of regional binding sites, and differential response of the normal vs. diseased heart (hypertensive cardiomyopathy) in an animal model to mimic a potentially high risk population. We investigated the acute effects of cocaine on myocardial metabolism using two myocardial energy substrate analogs, fatty acid and glucose with comparison with regional perfusion.

  11. Myocardial uptake of cocaine and effects of cocaine on myocardial substrate utilization and perfusion in hypertensive rats

    Energy Technology Data Exchange (ETDEWEB)

    Som, P.; Wang, G.J. (Brookhaven National Lab., Upton, NY (United States)); Oster, Z.H. (State Univ. of New York, Stony Brook, NY (United States)); Knapp, F.F. Jr. (Oak Ridge National Lab., TN (United States)); Yonekura, Y. (Kyoto Univ. (Japan). Faculty of Medicine); Fujibayashi, Y. (Kyoto Univ. (Japan). Hospital); Yamamoto, K. (Fukui Univ. (Japan). Medical School); Kubota, K. (Tohoku Univ., Sendai

    1992-01-01

    Cocaine abuse is a problem causing world-wide concern and the number of deaths following cocaine use is increasing. Cardiovascular complications following cocaine include severe tachyarrythmias, pulmonary edema, myocardial infarction, and acute renal failure, which are major problems confronting emergency facilities. While the studies of cocaine effects on the brain have been given the most attention, it is clear that the effects of cocaine on the cardiovascular system are of great importance, given the increasing number of reports on sudden death and myocardial infarctions in young adults related to cocaine use. The precise mechanisms of cardiotoxic actions of cocaine are unclear. We investigated the whole-body distribution of C-14-labeled cocaine to determine the cocaine-binding sites, including blocking experiments to determine the nature of regional binding sites, and differential response of the normal vs. diseased heart (hypertensive cardiomyopathy) in an animal model to mimic a potentially high risk population. We investigated the acute effects of cocaine on myocardial metabolism using two myocardial energy substrate analogs, fatty acid and glucose with comparison with regional perfusion.

  12. Multi-resolution voxel phantom modeling: a high-resolution eye model for computational dosimetry.

    Science.gov (United States)

    Caracappa, Peter F; Rhodes, Ashley; Fiedler, Derek

    2014-09-21

    Voxel models of the human body are commonly used for simulating radiation dose with a Monte Carlo radiation transport code. Due to memory limitations, the voxel resolution of these computational phantoms is typically too large to accurately represent the dimensions of small features such as the eye. Recently reduced recommended dose limits to the lens of the eye, which is a radiosensitive tissue with a significant concern for cataract formation, has lent increased importance to understanding the dose to this tissue. A high-resolution eye model is constructed using physiological data for the dimensions of radiosensitive tissues, and combined with an existing set of whole-body models to form a multi-resolution voxel phantom, which is used with the MCNPX code to calculate radiation dose from various exposure types. This phantom provides an accurate representation of the radiation transport through the structures of the eye. Two alternate methods of including a high-resolution eye model within an existing whole-body model are developed. The accuracy and performance of each method is compared against existing computational phantoms.

  13. High-resolution intravital microscopy.

    Directory of Open Access Journals (Sweden)

    Volker Andresen

    Full Text Available Cellular communication constitutes a fundamental mechanism of life, for instance by permitting transfer of information through synapses in the nervous system and by leading to activation of cells during the course of immune responses. Monitoring cell-cell interactions within living adult organisms is crucial in order to draw conclusions on their behavior with respect to the fate of cells, tissues and organs. Until now, there is no technology available that enables dynamic imaging deep within the tissue of living adult organisms at sub-cellular resolution, i.e. detection at the level of few protein molecules. Here we present a novel approach called multi-beam striped-illumination which applies for the first time the principle and advantages of structured-illumination, spatial modulation of the excitation pattern, to laser-scanning-microscopy. We use this approach in two-photon-microscopy--the most adequate optical deep-tissue imaging-technique. As compared to standard two-photon-microscopy, it achieves significant contrast enhancement and up to 3-fold improved axial resolution (optical sectioning while photobleaching, photodamage and acquisition speed are similar. Its imaging depth is comparable to multifocal two-photon-microscopy and only slightly less than in standard single-beam two-photon-microscopy. Precisely, our studies within mouse lymph nodes demonstrated 216% improved axial and 23% improved lateral resolutions at a depth of 80 µm below the surface. Thus, we are for the first time able to visualize the dynamic interactions between B cells and immune complex deposits on follicular dendritic cells within germinal centers (GCs of live mice. These interactions play a decisive role in the process of clonal selection, leading to affinity maturation of the humoral immune response. This novel high-resolution intravital microscopy method has a huge potential for numerous applications in neurosciences, immunology, cancer research and

  14. High-Resolution Intravital Microscopy

    Science.gov (United States)

    Andresen, Volker; Pollok, Karolin; Rinnenthal, Jan-Leo; Oehme, Laura; Günther, Robert; Spiecker, Heinrich; Radbruch, Helena; Gerhard, Jenny; Sporbert, Anje; Cseresnyes, Zoltan; Hauser, Anja E.; Niesner, Raluca

    2012-01-01

    Cellular communication constitutes a fundamental mechanism of life, for instance by permitting transfer of information through synapses in the nervous system and by leading to activation of cells during the course of immune responses. Monitoring cell-cell interactions within living adult organisms is crucial in order to draw conclusions on their behavior with respect to the fate of cells, tissues and organs. Until now, there is no technology available that enables dynamic imaging deep within the tissue of living adult organisms at sub-cellular resolution, i.e. detection at the level of few protein molecules. Here we present a novel approach called multi-beam striped-illumination which applies for the first time the principle and advantages of structured-illumination, spatial modulation of the excitation pattern, to laser-scanning-microscopy. We use this approach in two-photon-microscopy - the most adequate optical deep-tissue imaging-technique. As compared to standard two-photon-microscopy, it achieves significant contrast enhancement and up to 3-fold improved axial resolution (optical sectioning) while photobleaching, photodamage and acquisition speed are similar. Its imaging depth is comparable to multifocal two-photon-microscopy and only slightly less than in standard single-beam two-photon-microscopy. Precisely, our studies within mouse lymph nodes demonstrated 216% improved axial and 23% improved lateral resolutions at a depth of 80 µm below the surface. Thus, we are for the first time able to visualize the dynamic interactions between B cells and immune complex deposits on follicular dendritic cells within germinal centers (GCs) of live mice. These interactions play a decisive role in the process of clonal selection, leading to affinity maturation of the humoral immune response. This novel high-resolution intravital microscopy method has a huge potential for numerous applications in neurosciences, immunology, cancer research and developmental biology

  15. Investigation of (/sup 18/F)2-fluoro-2-deoxyglucose for the measure of myocardial glucose metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Phelps, M.E.; Hoffman, E.J.; Selin, C.; Huang, S.C.; Robinson, G.; MacDonald, N.; Schelbert, H.; Kuhl, D.E.

    1978-12-01

    Fluorine-18-labeled 2-deoxyglucose (FDG) was studied as a glucose analog for the measure of myocardial glucose metabolism. Myocardial uptake and retention, blood clearance, species dependence (dog, monkey, man), and effect of diet on uptake were investigated. Normal myocardial uptake of FDG was 3 to 4% of injected dose in dog and monkey, and 1 to 4% in man, compared with brain uptakes of 1.5 to 3% in dog, 5 to 6% in monkey, and 4 to 8% in man. The myocardial metabolic rate (MR) for glucose in the nonfasting (glycolytic) state was 2.8 times that in the fasting (ketogenic) state. Human subjects showed higher myocardial uptake after a normal meal than after a meal containing mostly free fatty acids (FFA). Blood clearance was rapid with initial clearance t/sub 1/2/ of 0.2 to 0.3 min, followed by a t/sub 1/2/ of 8.4 +- 1.2 min in dog and 11.6 +- 1.1 min in man. A small third component had half-times of 59 +- 10 min and 88 +- 4 min in dog and man, respectively. With the ECAT positron tomograph, high image-contrast ratios were found between heart and blood (dog 3.5/1, man 14/1), heart and lung (dog 9/1, man 20/1), and heart and liver (dog 15/1, man 10/1). The FDG was taken up rapidly by the myocardium without any significant tissue clearance over a 4-hr period. The FDG exhibited excellent imaging properties. Average counting rates of 12K, 20K, and 40K c/min-mCi injected are obtained in human subjects with high, medium, and low resolutions of the ECAT tomograph. Determination of glucose and FFA MR in vivo with EACT provides a method for investigation and assessment of changing aerobic and anaerobic metabolic rates in ischemic heart disease in man.

  16. Automated quantitative coronary computed tomography correlates of myocardial ischaemia on gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Graaf, Michiel A. de; Boogers, Mark J.; Veltman, Caroline E.; El-Naggar, Heba M.; Bax, Jeroen J.; Delgado, Victoria; Broersen, Alexander; Kitslaar, Pieter H.; Dijkstra, Jouke; Kroft, Lucia J.; Younis, Imad Al; Reiber, Johan H.; Scholte, Arthur J.

    2013-01-01

    Automated software tools have permitted more comprehensive, robust and reproducible quantification of coronary stenosis, plaque burden and plaque location of coronary computed tomography angiography (CTA) data. The association between these quantitative CTA (QCT) parameters and the presence of myocardial ischaemia has not been explored. The aim of the present investigation was to evaluate the association between QCT parameters of coronary artery lesions and the presence of myocardial ischaemia on gated myocardial perfusion single-photon emission CT (SPECT). Included in the study were 40 patients (mean age 58.2 ± 10.9 years, 27 men) with known or suspected coronary artery disease (CAD) who had undergone multidetector row CTA and gated myocardial perfusion SPECT within 6 months. From the CTA datasets, vessel-based and lesion-based visual analyses were performed. Consecutively, lesion-based QCT was performed to assess plaque length, plaque burden, percentage lumen area stenosis and remodelling index. Subsequently, the presence of myocardial ischaemia was assessed using the summed difference score (SDS ≥2) on gated myocardial perfusion SPECT. Myocardial ischaemia was seen in 25 patients (62.5 %) in 37 vascular territories. Quantitatively assessed significant stenosis and quantitatively assessed lesion length were independently associated with myocardial ischaemia (OR 7.72, 95 % CI 2.41-24.7, p 2 = 20.7) and lesion length (χ 2 = 26.0) to the clinical variables and the visual assessment (χ 2 = 5.9) had incremental value in the association with myocardial ischaemia. Coronary lesion length and quantitatively assessed significant stenosis were independently associated with myocardial ischaemia. Both quantitative parameters have incremental value over baseline variables and visually assessed significant stenosis. Potentially, QCT can refine assessment of CAD, which may be of potential use for identification of patients with myocardial ischaemia. (orig.)

  17. Effect of eating on thallium-201 myocardial redistribution after myocardial ischemia

    International Nuclear Information System (INIS)

    Angello, D.A.; Wilson, R.A.; Palac, R.T.

    1987-01-01

    To determine whether eating a high-carbohydrate meal between initial and delayed postexercise thallium-201 (Tl-201) imaging affects detection of Tl-201 redistribution during exercise stress testing, 16 patients with stable angina performed 2 Tl-201 treadmill exercise stress tests within a 14-day interval. Immediately after initial postexercise imaging, patients either drank a commercially available instant breakfast preparation for the intervention test or drank an equivalent volume of water for the control test. Comparable exercise workloads were achieved by exercising patients to the same heart rate for both tests. The order of the 2 (intervention and control) tests were randomized. All patients had at least 1 region of Tl-201 myocardial redistribution on either their eating or control test scans, although only 7 of the 16 had positive treadmill exercise test responses. Forty-six regions showing Tl-201 myocardial redistribution were identified in all 144 regions examined. Significantly more of these regions were identified on control test scans than on eating test scans: 11 of 46 on both test scans, 6 of 46 only on eating test scans and 29 of 46 only on control scans (p less than 0.001). Consistent with results of the quantitative regional analysis, the percentage of Tl-201 clearance over 4 hours in the 46 Tl-201 myocardial redistribution regions was 39 +/- 8% for the eating tests and 29 +/- 8% for control tests (mean +/- standard deviation, p less than 0.003). In 4 patients diagnosis of transient ischemia would have been missed because their 14 Tl-201 myocardial redistribution regions were detected only on the control test scans

  18. Hyper-resolution urban flood modeling using high-resolution radar precipitation and LiDAR data

    Science.gov (United States)

    Noh, S. J.; Lee, S.; Lee, J.; Seo, D. J.

    2016-12-01

    Floods occur most frequently among all natural hazards, often causing widespread economic damage and loss of human lives. In particular, urban flooding is becoming increasingly costly and difficult to manage with a greater concentration of population and assets in urban centers. Despite of known benefits for accurate representation of small scale features and flow interaction among different flow domains, which have significant impact on flood propagation, high-resolution modeling has not been fully utilized due to expensive computation and various uncertainties from model structure, input and parameters. In this study, we assess the potential of hyper-resolution hydrologic-hydraulic modeling using high-resolution radar precipitation and LiDAR data for improved urban flood prediction and hazard mapping. We describe a hyper-resolution 1D-2D coupled urban flood model for pipe and surface flows and evaluate the accuracy of the street-level inundation information produced. For detailed geometric representation of urban areas and for computational efficiency, we use 1 m-resolution topographical data, processed from LiDAR measurements, in conjunction with adaptive mesh refinement. For street-level simulation in large urban areas at grid sizes of 1 to 10 m, a hybrid parallel computing scheme using MPI and openMP is also implemented in a high-performance computing system. The modeling approach developed is applied for the Johnson Creek Catchment ( 40 km2), which makes up the Arlington Urban Hydroinformatics Testbed. In addition, discussion will be given on availability of hyper-resolution simulation archive for improved real-time flood mapping.

  19. Analysis of the impact of spatial resolution on land/water classifications using high-resolution aerial imagery

    Science.gov (United States)

    Enwright, Nicholas M.; Jones, William R.; Garber, Adrienne L.; Keller, Matthew J.

    2014-01-01

    Long-term monitoring efforts often use remote sensing to track trends in habitat or landscape conditions over time. To most appropriately compare observations over time, long-term monitoring efforts strive for consistency in methods. Thus, advances and changes in technology over time can present a challenge. For instance, modern camera technology has led to an increasing availability of very high-resolution imagery (i.e. submetre and metre) and a shift from analogue to digital photography. While numerous studies have shown that image resolution can impact the accuracy of classifications, most of these studies have focused on the impacts of comparing spatial resolution changes greater than 2 m. Thus, a knowledge gap exists on the impacts of minor changes in spatial resolution (i.e. submetre to about 1.5 m) in very high-resolution aerial imagery (i.e. 2 m resolution or less). This study compared the impact of spatial resolution on land/water classifications of an area dominated by coastal marsh vegetation in Louisiana, USA, using 1:12,000 scale colour-infrared analogue aerial photography (AAP) scanned at four different dot-per-inch resolutions simulating ground sample distances (GSDs) of 0.33, 0.54, 1, and 2 m. Analysis of the impact of spatial resolution on land/water classifications was conducted by exploring various spatial aspects of the classifications including density of waterbodies and frequency distributions in waterbody sizes. This study found that a small-magnitude change (1–1.5 m) in spatial resolution had little to no impact on the amount of water classified (i.e. percentage mapped was less than 1.5%), but had a significant impact on the mapping of very small waterbodies (i.e. waterbodies ≤ 250 m2). These findings should interest those using temporal image classifications derived from very high-resolution aerial photography as a component of long-term monitoring programs.

  20. Short-lived cyclotron produced radionuclides evaluation on the myocardial imaging agents

    International Nuclear Information System (INIS)

    Rikitake, Tomoyuki; Tateno, Yukio; Yamane, Akiko; Matsumoto, Touru; Umegaki, Youichiro

    1978-01-01

    Organ uptake after venous administration of 13 N-ammonia, 43 K, 86 Rb, 201 Tl and after rectal administration of 13 N-ammonia was studied. Each nuclides highly accumulated in myocardium after intravenous injection, but rectal administrated 13 N-ammonia did not show this tendency. Intravenously injected 13 N-ammonia showed very early myocardial uptake and early secretion from kidney. Rectal administrated 13 N-ammonia was less accumulated in myocardium. 43 KCl and 13 NH 4 Cl were injected intravenously and administrated from the rectum to the rabbits under imaging scintilator system. Whole-body scintiscanner with display-processing unit was used for a 43 KCl injected rabbit. A positroncamera with computer system (TOSBAC 3400 on line system) was used for 13 NH 4 Cl (i.v. and rectal ad.) rabbits. The dynamic studies of 43 KCl, 13 NH 4 Cl were made from these imaging data. The countratio of heart to the liver after 43 K injection was nearly equal or less than the liver. The peakcount was at 15 min after 13 NH 4 Cl intravenous injection. 13 N accumulated promptly at upper mediastinal part and kidney, and soon disappeared from these part. Uptake of the heat was high and that of the liver was low. When 13 NH 4 Cl was administrated from the rectum, 13 N trapped at the liver, and uptake of the heart was very low level. Scintiscanning after 13 KCl intravenously injected, did not show the high resolution. Rabbit heart was distinguishable from the liver, but there are no visibility of the detail. Seeing positronscintigram after 13 NH 4 Cl administration both from intravenously and from rectum, the detail was well visible. We concluded the positron scintigram after 13 NH 4 Cl injection should be a good myocardial imaging agent. Furthermore, 13 Nh 4 Cl has two eminent characters as a myocardial imaging agent comparing 201 TlCl. One is prompt making of image, the others is the very low radiation dose. (auth.)

  1. Image Quality in High-resolution and High-cadence Solar Imaging

    Science.gov (United States)

    Denker, C.; Dineva, E.; Balthasar, H.; Verma, M.; Kuckein, C.; Diercke, A.; González Manrique, S. J.

    2018-03-01

    Broad-band imaging and even imaging with a moderate bandpass (about 1 nm) provides a photon-rich environment, where frame selection (lucky imaging) becomes a helpful tool in image restoration, allowing us to perform a cost-benefit analysis on how to design observing sequences for imaging with high spatial resolution in combination with real-time correction provided by an adaptive optics (AO) system. This study presents high-cadence (160 Hz) G-band and blue continuum image sequences obtained with the High-resolution Fast Imager (HiFI) at the 1.5-meter GREGOR solar telescope, where the speckle-masking technique is used to restore images with nearly diffraction-limited resolution. The HiFI employs two synchronized large-format and high-cadence sCMOS detectors. The median filter gradient similarity (MFGS) image-quality metric is applied, among others, to AO-corrected image sequences of a pore and a small sunspot observed on 2017 June 4 and 5. A small region of interest, which was selected for fast-imaging performance, covered these contrast-rich features and their neighborhood, which were part of Active Region NOAA 12661. Modifications of the MFGS algorithm uncover the field- and structure-dependency of this image-quality metric. However, MFGS still remains a good choice for determining image quality without a priori knowledge, which is an important characteristic when classifying the huge number of high-resolution images contained in data archives. In addition, this investigation demonstrates that a fast cadence and millisecond exposure times are still insufficient to reach the coherence time of daytime seeing. Nonetheless, the analysis shows that data acquisition rates exceeding 50 Hz are required to capture a substantial fraction of the best seeing moments, significantly boosting the performance of post-facto image restoration.

  2. Myocardial potency of Bio-tea against Isoproterenol induced myocardial damage in rats.

    Science.gov (United States)

    Lobo, Reema Orison; Shenoy, Chandrakala K

    2015-07-01

    Kombucha (Bio-tea) is a beverage produced by the fermentation of sugared black tea using a symbiotic association of bacteria and yeasts. Traditional claims about Kombucha report beneficial effects such as antibiotic properties, gastric regulation, relief from joint rheumatism and positive influence on the cholesterol level, arteriosclerosis, diabetes, and aging problems. The present investigation was carried out to understand the preventive effect of Kombucha on heart weight, blood glucose, total protein, lipid profile and cardiac markers in rats with myocardial damage induced using Isoproterenol. As Bio-tea is produced by fermenting tea, the parameters were compared in rats pre-treated with normal black tea and Bio-tea for 30 days followed by subcutaneous injection of Isoproterenol (85 mg/kg body weight). Normal rats as well as Isoproterenol induced myocardial infarcted rats were also used, which served as controls. Isoproterenol induced myocardial infarcted control rats showed a significant increase in heart weight, blood glucose and cardiac markers and a decrease in plasma protein. Increased levels of cholesterol, triglycerides, low density lipids (LDL) and very low density lipids (VLDL) were also observed, while the high density lipid (HDL) content decreased. Bio-tea showed a higher preventive effect against myocardial infarction when compared to tea, as was observed by the significant reduction in heart weight, and blood glucose and increase in plasma albumin levels. Bio-tea significantly decreased cholesterol, triglycerides, LDL and VLDL while simultaneously increasing the levels of HDL. Similarly a decrease in leakage of cardiac markers from the myocardium was also observed.

  3. Myocardial contusion in patients with blunt chest trauma as evaluated by thallium 201 myocardial scintigraphy

    International Nuclear Information System (INIS)

    Bodin, L.; Rouby, J.J.; Viars, P.

    1988-01-01

    Fifty five patients suffering from blunt chest trauma were studied to assess the diagnosis of myocardial contusion using thallium 201 myocardial scintigraphy. Thirty-eight patients had consistent scintigraphic defects and were considered to have a myocardial contusion. All patients with scintigraphic defects had paroxysmal arrhythmias and/or ECG abnormalities. Of 38 patients, 32 had localized ST-T segment abnormalities; 29, ST-T segment abnormalities suggesting involvement of the same cardiac area as scintigraphic defects; 21, echocardiographic abnormalities. Sixteen patients had segmental hypokinesia involving the same cardiac area as the scintigraphic defects. Fifteen patients had clinical signs suggestive of myocardial contusion and scintigraphic defects. Almost 70 percent of patients with blunt chest trauma had scintigraphic defects related to areas of myocardial contusion. When thallium 201 myocardial scintigraphy directly showed myocardial lesion, two-dimensional echocardiography and standard ECG detected related functional consequences of cardiac trauma

  4. Significant suppression of myocardial (18)F-fluorodeoxyglucose uptake using 24-h carbohydrate restriction and a low-carbohydrate, high-fat diet.

    Science.gov (United States)

    Kobayashi, Yasuhiro; Kumita, Shin-ichiro; Fukushima, Yoshimitsu; Ishihara, Keiichi; Suda, Masaya; Sakurai, Minoru

    2013-11-01

    (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) is a useful tool for evaluating inflammation. Because, myocardial-FDG uptake occurs with diverse physiology, it should be suppressed during evaluation of myocardial inflammation by FDG-PET/CT. Diets inducing fat-based metabolism, such as a low-carbohydrate, high-fat diet (LCHF), are used in uptake-suppression protocols. However, a complete suppression of myocardial-FDG uptake has not been established. Hence, we assessed the efficacy of 24-h carbohydrate restriction along with an LCHF diet compared to that of the conventional protocol in suppressing myocardial-FDG uptake and also compared fat and glucose metabolism between these protocols. Fourteen healthy volunteers agreed to undergo >24-h carbohydrate restriction (glucose, vs. 2.98 [1.76-6.43], p=0.001). Target-to-background ratios [myocardium-to-blood ratio (MBR), myocardium-to-lung ratio (MLR), and myocardium-to-liver ratio (MLvR)] were also significantly lower with the diet-preparation protocol [MBR: 0.75 (0.68-0.84) vs. 1.63 (0.98-4.09), pvs. 4.54 (2.53-12.78), p=0.004; MLvR: 0.48 (0.44-0.56) vs. 1.11 (0.63-2.32), p=0.002]. Only insulin levels were significantly different between the subjects in each protocol group (11.3 [6.2-15.1] vs. 3.9 [2.9-6.2]). Carbohydrate restriction together with an LCHF supplement administered 1h before FDG significantly suppressed myocardial-FDG uptake. FFAs and insulin might not directly affect myocardial-FDG uptake. Copyright © 2013 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  5. Smartphone microendoscopy for high resolution fluorescence imaging

    Directory of Open Access Journals (Sweden)

    Xiangqian Hong

    2016-09-01

    Full Text Available High resolution optical endoscopes are increasingly used in diagnosis of various medical conditions of internal organs, such as the cervix and gastrointestinal (GI tracts, but they are too expensive for use in resource-poor settings. On the other hand, smartphones with high resolution cameras and Internet access have become more affordable, enabling them to diffuse into most rural areas and developing countries in the past decade. In this paper, we describe a smartphone microendoscope that can take fluorescence images with a spatial resolution of 3.1 μm. Images collected from ex vivo, in vitro and in vivo samples using the device are also presented. The compact and cost-effective smartphone microendoscope may be envisaged as a powerful tool for detecting pre-cancerous lesions of internal organs in low and middle-income countries (LMICs.

  6. Exercise induced ST elevation and residual myocardial ischemia in previous myocardial infarction

    International Nuclear Information System (INIS)

    Shimonagata, Tsuyoshi; Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Saito, Muneyasu; Sumiyoshi, Tetsuya

    1987-01-01

    The purpose of this study was to evaluate the clinical significance of stress induced ST elevation on infarcted area in 65 patients with previous myocardial infarction (single vessel disease) who had stress thallium scan. Stress induced ST changes on infarcted area were compared with quantitative assessment of myocardial ischemia (thallium ischemic score; TIS) and extent of myocardial infarction (defect score; DS) derived from circumferential profile analysis. In patients with previous myocardial infarction in less than 3 month from the onset (n = 36), left ventricular ejection fraction (LVEF) and extent of abnormal LV wall motion were not significantly different between patients with stress induced ST elevation ( ≥ 2 mm, n = 26) and those with stress induced ST elevation ( < 2 mm, n = 10), while, in patients with previous myocardial infarction in more than 3 month (n = 29), patients with stress induced ST elevation ( ≥ 2 mm, n = 15) showed left ventricular dyskinesis more frequently than those with ST elevation ( < 2 mm, n = 14). In addition, the former showed significantly higher DS and significantly lower TIS than the latter. In patients with previous myocardial infarction in less than 3 month, patients with ST elevation ( ≥ 2 mm, n = 15) with prominent upright T wave (n = 15) had transient thallium defect in infarcted area in 73 % and they had significantly higher LVEF and TIS than those with ST elevation ( < 2 mm, n = 11). These results indicated that ST elevation in infarcted area reflect different significance according to the recovery of injured myocardium and stress induced ST elevation with prominent upright T wave in infarcted area reflect residual myocardial ischemia in less than 3 month from the onset of myocardial infarction. (author)

  7. High resolution mid-infrared spectroscopy based on frequency upconversion

    DEFF Research Database (Denmark)

    Dam, Jeppe Seidelin; Hu, Qi; Tidemand-Lichtenberg, Peter

    2013-01-01

    signals can be analyzed. The obtainable frequency resolution is usually in the nm range where sub nm resolution is preferred in many applications, like gas spectroscopy. In this work we demonstrate how to obtain sub nm resolution when using upconversion. In the presented realization one object point...... high resolution spectral performance by observing emission from hot water vapor in a butane gas burner....

  8. Climate change and high-resolution whole-building numerical modelling

    NARCIS (Netherlands)

    Blocken, B.J.E.; Briggen, P.M.; Schellen, H.L.; Hensen, J.L.M.

    2010-01-01

    This paper briefly discusses the need of high-resolution whole-building numerical modelling in the context of climate change. High-resolution whole-building numerical modelling can be used for detailed analysis of the potential consequences of climate change on buildings and to evaluate remedial

  9. Myocardial ischemia in hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Lima Filho, Moyses de Oliveira; Figueiredo, Geraldo L.; Simoes, Marcus V.; Pyntia, Antonio O.; Marin Neto, Jose Antonio

    2000-01-01

    Myocardial ischemia in hypertrophic cardiomyopathy is multifactorial and explains the occurrence of angina, in about 50% of patients. The pathophysiology of myocardial ischemia may be explained by the increase of the ventricular mass and relative paucity of the coronary microcirculation; the elevated ventricular filling pressures and myocardial stiffness causing a compression of the coronary microvessels; the impaired coronary vasodilator flow reserve caused by anatomic and functional abnormalities; and the systolic compression of epicardial vessel (myocardial bridges). Myocardial ischemia must be investigated by perfusion scintigraphic methods since its presence influences the prognosis and has relevant clinical implications for management of patients. Patients with hypertrophic cardiomyopathy and documented myocardial ischemia usually need to undergo invasive coronary angiography to exclude the presence of concomitant atherosclerotic coronary disease. (author)

  10. New approach to 3-D, high sensitivity, high mass resolution space plasma composition measurements

    International Nuclear Information System (INIS)

    McComas, D.J.; Nordholt, J.E.

    1990-01-01

    This paper describes a new type of 3-D space plasma composition analyzer. The design combines high sensitivity, high mass resolution measurements with somewhat lower mass resolution but even higher sensitivity measurements in a single compact and robust design. While the lower resolution plasma measurements are achieved using conventional straight-through time-of-flight mass spectrometry, the high mass resolution measurements are made by timing ions reflected in a linear electric field (LEF), where the restoring force that an ion experiences is proportional to the depth it travels into the LEF region. Consequently, the ion's equation of motion in that dimension is that of a simple harmonic oscillator and its travel time is simply proportional to the square root of the ion's mass/charge (m/q). While in an ideal LEF, the m/q resolution can be arbitrarily high, in a real device the resolution is limited by the field linearity which can be achieved. In this paper we describe how a nearly linear field can be produced and discuss how the design can be optimized for various different plasma regimes and spacecraft configurations

  11. Evaluation of attenuation correction, scatter correction and resolution recovery in myocardial Tc-99m MIBI SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Larcos, G.; Hutton, B.F.; Farlow, D.C.; Campbell- Rodgers, N.; Gruenewald, S.M.; Lau, Y.H. [Westmead Hospital, Westmead, Sydney, NSW (Australia). Departments of Nuclear Medicine and Ultrasound and Medical Physics

    1998-06-01

    Full text: The introduction of transmission based attenuation correction (AC) has increased the diagnostic accuracy of Tc-99m MIBI myocardial perfusion SPECT. The aim of this study is to evaluate recent developments, including scatter correction (SC) and resolution recovery (RR). We reviewed 13 patients who underwent Tc-99m MIBI SPECT (two day protocol) and coronary angiography and 4 manufacturer supplied studies assigned a low pretest likelihood of coronary artery disease (CAD). Patients had a mean age of 59 years (range: 41-78). Data were reconstructed using filtered backprojection (FBP; method 1), maximum likelihood (ML) incorporating AC (method 2), ADAC software using sinogram based SC+RR followed by ML with AC (method 3) and ordered subset ML incorporating AC,SC and RR (method 4). Images were reported by two of three blinded experienced physicians using a standard semiquantitative scoring scheme. Fixed or reversible perfusion defects were considered abnormal; CAD was considered present with stenoses > 50%. Patients had normal coronary anatomy (n=9), single (n=4) or two vessel CAD (n=4) (four in each of LAD, RCA and LCX). There were no statistically significant differences for any combination. Normalcy rate = 100% for all methods. Physicians graded 3/17 (methods 2,4) and 1/17 (method 3) images as fair or poor in quality. Thus, AC or AC+SC+RR produce good quality images in most patients; there is potential for improvement in sensitivity over standard FBP with no significant change in normalcy or specificity

  12. Effect of antecedent hypertension and follow-up blood pressure on outcomes after high-risk myocardial infarction

    DEFF Research Database (Denmark)

    Thune, J.J.; Signorovitch, J.; Velazquez, E.J.

    2007-01-01

    myocardial infarction in the Valsartan in Myocardial Infarction Trial. We assessed the relationship between antecedent hypertension and outcomes and the association between elevated (systolic: >140 mm Hg) or low blood pressure (systolic:

  13. High resolution CT of the chest

    Energy Technology Data Exchange (ETDEWEB)

    Barneveld Binkhuysen, F H [Eemland Hospital (Netherlands), Dept. of Radiology

    1996-12-31

    Compared to conventional CT high resolution CT (HRCT) shows several extra anatomical structures which might effect both diagnosis and therapy. The extra anatomical structures were discussed briefly in this article. (18 refs.).

  14. Methodology of high-resolution photography for mural condition database

    Science.gov (United States)

    Higuchi, R.; Suzuki, T.; Shibata, M.; Taniguchi, Y.

    2015-08-01

    Digital documentation is one of the most useful techniques to record the condition of cultural heritage. Recently, high-resolution images become increasingly useful because it is possible to show general views of mural paintings and also detailed mural conditions in a single image. As mural paintings are damaged by environmental stresses, it is necessary to record the details of painting condition on high-resolution base maps. Unfortunately, the cost of high-resolution photography and the difficulty of operating its instruments and software have commonly been an impediment for researchers and conservators. However, the recent development of graphic software makes its operation simpler and less expensive. In this paper, we suggest a new approach to make digital heritage inventories without special instruments, based on our recent our research project in Üzümlü church in Cappadocia, Turkey. This method enables us to achieve a high-resolution image database with low costs, short time, and limited human resources.

  15. High-Resolution MRI in Rectal Cancer

    International Nuclear Information System (INIS)

    Dieguez, Adriana

    2010-01-01

    High-resolution MRI is the best method of assessing the relation of the rectal tumor with the potential circumferential resection margin (CRM). Therefore it is currently considered the method of choice for local staging of rectal cancer. The primary surgery of rectal cancer is total mesorectal excision (TME), which plane of dissection is formed by the mesorectal fascia surrounding mesorectal fat and rectum. This fascia will determine the circumferential margin of resection. At the same time, high resolution MRI allows adequate pre-operative identification of important prognostic risk factors, improving the selection and indication of therapy for each patient. This information includes, besides the circumferential margin of resection, tumor and lymph node staging, extramural vascular invasion and the description of lower rectal tumors. All these should be described in detail in the report, being part of the discussion in the multidisciplinary team, the place where the decisions involving the patient with rectal cancer will take place. The aim of this study is to provide the information necessary to understand the use of high resolution MRI in the identification of prognostic risk factors in rectal cancer. The technical requirements and standardized report for this study will be describe, as well as the anatomical landmarks of importance for the total mesorectal excision (TME), as we have said is the surgery of choice for rectal cancer. (authors) [es

  16. SPECT myocardial blood flow quantitation toward clinical use: a comparative study with {sup 13}N-Ammonia PET myocardial blood flow quantitation

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Bailing [University of Missouri-Columbia, Nuclear Science and Engineering Institute, Columbia, Missouri (United States); Hu, Lien-Hsin; Yang, Bang-Hung; Ting, Chien-Hsin; Huang, Wen-Sheng [Taipei Veterans General Hospital, Department of Nuclear Medicine, Taipei (China); Chen, Lung-Ching [Shin Kong Wu-Ho Su Memorial Hospital, Division of Cardiology, Taipei (China); Chen, Yen-Kung [Shin Kong Wu-Ho Su Memorial Hospital, Department of Nuclear Medicine, Taipei (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Changhua (China); Wu, Tao-Cheng [National Yang-Ming University, Cardiovascular Research Center, Taipei (China)

    2017-01-15

    The aim of this study was to evaluate the accuracy of myocardial blood flow (MBF) quantitation of {sup 99m}Tc-Sestamibi (MIBI) single photon emission computed tomography (SPECT) compared with {sup 13}N-Ammonia (NH3) position emission tomography (PET) on the same cohorts. Recent advances of SPECT technologies have been applied to develop MBF quantitation as a promising tool to diagnose coronary artery disease (CAD) for areas where PET MBF quantitation is not available. However, whether the SPECT approach can achieve the same level of accuracy as the PET approach for clinical use still needs further investigations. Twelve healthy volunteers (HVT) and 16 clinical patients with CAD received both MIBI SPECT and NH3 PET flow scans. Dynamic SPECT images acquired with high temporary resolution were fully corrected for physical factors and processed to quantify K1 using the standard compartmental modeling. Human MIBI tracer extraction fraction (EF) was determined by comparing MIBI K1 and NH3 flow on the HVT group and then used to convert flow values from K1 for all subjects. MIBI and NH3 flow values were systematically compared to validate the SPECT approach. The human MIBI EF was determined as [1.0-0.816*exp(-0.267/MBF)]. Global and regional MBF and myocardial flow reserve (MFR) of MIBI SPECT and NH3 PET were highly correlated for all subjects (global R{sup 2}: MBF = 0.92, MFR = 0.78; regional R{sup 2}: MBF ≥ 0.88, MFR ≥ 0.71). No significant differences for rest flow, stress flow, and MFR between these two approaches were observed (All p ≥ 0.088). Bland-Altman plots overall revealed small bias between MIBI SPECT and NH3 PET (global: ΔMBF = -0.03Lml/min/g, ΔMFR = 0.07; regional: ΔMBF = -0.07 - 0.06, ΔMFR = -0.02 - 0.22). Quantitation with SPECT technologies can be accurate to measure myocardial blood flow as PET quantitation while comprehensive imaging factors of SPECT to derive the variability between these two approaches were fully addressed and corrected

  17. SPECT myocardial blood flow quantitation toward clinical use: a comparative study with "1"3N-Ammonia PET myocardial blood flow quantitation

    International Nuclear Information System (INIS)

    Hsu, Bailing; Hu, Lien-Hsin; Yang, Bang-Hung; Ting, Chien-Hsin; Huang, Wen-Sheng; Chen, Lung-Ching; Chen, Yen-Kung; Hung, Guang-Uei; Wu, Tao-Cheng

    2017-01-01

    The aim of this study was to evaluate the accuracy of myocardial blood flow (MBF) quantitation of "9"9"mTc-Sestamibi (MIBI) single photon emission computed tomography (SPECT) compared with "1"3N-Ammonia (NH3) position emission tomography (PET) on the same cohorts. Recent advances of SPECT technologies have been applied to develop MBF quantitation as a promising tool to diagnose coronary artery disease (CAD) for areas where PET MBF quantitation is not available. However, whether the SPECT approach can achieve the same level of accuracy as the PET approach for clinical use still needs further investigations. Twelve healthy volunteers (HVT) and 16 clinical patients with CAD received both MIBI SPECT and NH3 PET flow scans. Dynamic SPECT images acquired with high temporary resolution were fully corrected for physical factors and processed to quantify K1 using the standard compartmental modeling. Human MIBI tracer extraction fraction (EF) was determined by comparing MIBI K1 and NH3 flow on the HVT group and then used to convert flow values from K1 for all subjects. MIBI and NH3 flow values were systematically compared to validate the SPECT approach. The human MIBI EF was determined as [1.0-0.816*exp(-0.267/MBF)]. Global and regional MBF and myocardial flow reserve (MFR) of MIBI SPECT and NH3 PET were highly correlated for all subjects (global R"2: MBF = 0.92, MFR = 0.78; regional R"2: MBF ≥ 0.88, MFR ≥ 0.71). No significant differences for rest flow, stress flow, and MFR between these two approaches were observed (All p ≥ 0.088). Bland-Altman plots overall revealed small bias between MIBI SPECT and NH3 PET (global: ΔMBF = -0.03Lml/min/g, ΔMFR = 0.07; regional: ΔMBF = -0.07 - 0.06, ΔMFR = -0.02 - 0.22). Quantitation with SPECT technologies can be accurate to measure myocardial blood flow as PET quantitation while comprehensive imaging factors of SPECT to derive the variability between these two approaches were fully addressed and corrected. (orig.)

  18. High-resolution coherent three-dimensional spectroscopy of Br2.

    Science.gov (United States)

    Chen, Peter C; Wells, Thresa A; Strangfeld, Benjamin R

    2013-07-25

    In the past, high-resolution spectroscopy has been limited to small, simple molecules that yield relatively uncongested spectra. Larger and more complex molecules have a higher density of peaks and are susceptible to complications (e.g., effects from conical intersections) that can obscure the patterns needed to resolve and assign peaks. Recently, high-resolution coherent two-dimensional (2D) spectroscopy has been used to resolve and sort peaks into easily identifiable patterns for molecules where pattern-recognition has been difficult. For very highly congested spectra, however, the ability to resolve peaks using coherent 2D spectroscopy is limited by the bandwidth of instrumentation. In this article, we introduce and investigate high-resolution coherent three-dimensional spectroscopy (HRC3D) as a method for dealing with heavily congested systems. The resulting patterns are unlike those in high-resolution coherent 2D spectra. Analysis of HRC3D spectra could provide a means for exploring the spectroscopy of large and complex molecules that have previously been considered too difficult to study.

  19. The value of gated myocardial perfusion imaging for the evaluation of early treatment effectiveness of ischemic heart disease using Ad-HGF myocardial injection

    International Nuclear Information System (INIS)

    Feng Jianlin; Cheng Xu; Li Jianhua; Xu Zhaoqiang; Li Dianfu; Yuan Biao; Zhang Yourong; Cao Kejiang; Huang Jun

    2008-01-01

    Objective: Hepatocyte growth factor (HGF) has multipotent actions mediated by c- Mesenchymal epithelial transition factor (Met) receptor. Preclinical studies in animal models of myocardial ischemia demonstrated that treatment with HGF could benefit myocardial perfusion, cardiac remodeling, angiogenesis and myocardial function. This study used gated 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging (G-MPI) to assess the early treatment effectiveness of adenovirus HGF (Ad-HGF) directly administered in ischemic heart disease (IHD) patients. Methods: Eighteen patients with IHD were divided into 3 groups receiving low dose [5 x 10 8 plaque forming unit (PFU)/site], medium (1.5 x 10 9 PFU/site) and high dose (5 x l0 9 PFU/site) of Ad-HGF. And the Ad-HGF was injected at 10 sites in each patient. Rest G-MPI was performed before and after treatment for myocardial perfusion and left ventricular function measurement. Stata 7.0 was used to analyse the data. Results: (1) After Ad-HGF, myocardial perfusion was improved in 3/6, 5/6 and 6/6 patients in low, medium and high dosage groups. The dosage of AD-HGF was closely correlated with the improvement of myocardial perfusion (χ 2 =4.34, P<0.05). (2) Left ventricular ejection fraction (LVEF) was significantly increased [(50.1 ± 6.4)% vs (58.7 ± 5.6)%, t=6.1, P<0.01], end-diastolic volume [EDV, (137.7 ± 33.2) ml vs (123.7 ± 32.7) ml] and end-systolic volume [ESV, (70.2 ± 22.4) ml vs (51.9 ± 14.9) ml] were significantly reduced. (3) The LVEFs were increased in all groups, and the LVEF improvement in the high dosage group [(8.6 ± 5.9)%] was significantly greater than the other two groups [(4.3 ± l.2)%, (6.8 ± 5.7)%]. The difference of post-treatment improvement on LVEF between the low and medium dosage groups was not significant. The dosage of Ad-HGF was closely correlated with the improvement of LVEF (r=0.67, P< 0.01). Conclusion: G-MPI is a reliable method for evaluating the early effectiveness of

  20. Automated quantitative coronary computed tomography correlates of myocardial ischaemia on gated myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Graaf, Michiel A. de; Boogers, Mark J.; Veltman, Caroline E. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); The Interuniversity Cardiology Institute of The Netherlands, Utrecht (Netherlands); El-Naggar, Heba M.; Bax, Jeroen J.; Delgado, Victoria [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); Broersen, Alexander; Kitslaar, Pieter H.; Dijkstra, Jouke [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Kroft, Lucia J. [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Younis, Imad Al [Leiden University Medical Center, Department of Nuclear Medicine, Leiden (Netherlands); Reiber, Johan H. [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Medis medical imaging systems B.V., Leiden (Netherlands); Scholte, Arthur J. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands)

    2013-08-15

    Automated software tools have permitted more comprehensive, robust and reproducible quantification of coronary stenosis, plaque burden and plaque location of coronary computed tomography angiography (CTA) data. The association between these quantitative CTA (QCT) parameters and the presence of myocardial ischaemia has not been explored. The aim of the present investigation was to evaluate the association between QCT parameters of coronary artery lesions and the presence of myocardial ischaemia on gated myocardial perfusion single-photon emission CT (SPECT). Included in the study were 40 patients (mean age 58.2 {+-} 10.9 years, 27 men) with known or suspected coronary artery disease (CAD) who had undergone multidetector row CTA and gated myocardial perfusion SPECT within 6 months. From the CTA datasets, vessel-based and lesion-based visual analyses were performed. Consecutively, lesion-based QCT was performed to assess plaque length, plaque burden, percentage lumen area stenosis and remodelling index. Subsequently, the presence of myocardial ischaemia was assessed using the summed difference score (SDS {>=}2) on gated myocardial perfusion SPECT. Myocardial ischaemia was seen in 25 patients (62.5 %) in 37 vascular territories. Quantitatively assessed significant stenosis and quantitatively assessed lesion length were independently associated with myocardial ischaemia (OR 7.72, 95 % CI 2.41-24.7, p < 0.001, and OR 1.07, 95 % CI 1.00-1.45, p = 0.032, respectively) after correcting for clinical variables and visually assessed significant stenosis. The addition of quantitatively assessed significant stenosis ({chi} {sup 2} = 20.7) and lesion length ({chi} {sup 2} = 26.0) to the clinical variables and the visual assessment ({chi} {sup 2} = 5.9) had incremental value in the association with myocardial ischaemia. Coronary lesion length and quantitatively assessed significant stenosis were independently associated with myocardial ischaemia. Both quantitative parameters have

  1. High resolution gamma-ray spectroscopy at high count rates with a prototype High Purity Germanium detector

    Science.gov (United States)

    Cooper, R. J.; Amman, M.; Vetter, K.

    2018-04-01

    High-resolution gamma-ray spectrometers are required for applications in nuclear safeguards, emergency response, and fundamental nuclear physics. To overcome one of the shortcomings of conventional High Purity Germanium (HPGe) detectors, we have developed a prototype device capable of achieving high event throughput and high energy resolution at very high count rates. This device, the design of which we have previously reported on, features a planar HPGe crystal with a reduced-capacitance strip electrode geometry. This design is intended to provide good energy resolution at the short shaping or digital filter times that are required for high rate operation and which are enabled by the fast charge collection afforded by the planar geometry crystal. In this work, we report on the initial performance of the system at count rates up to and including two million counts per second.

  2. Myocardial perfusion assessment by dual-energy computed tomography in patients with intermediate to high likelihood of coronary artery disease

    International Nuclear Information System (INIS)

    De Zam, M.C.; Capunay, C.; Rodriguez Granillo, G.A.; Deviggiano, A.; Campisi, R.; Munain, M. López de; Vallejos, J.; Carrascosa, P.M.

    2015-01-01

    Objectives. We sought to explore the feasibility and diagnostic performance of dual-energy computed tomography (DECT) for the evaluation of myocardial perfusion in patients with intermediate to high likelihood of coronary artery disease (CAD), and to assess the impact of beam hardening artifacts (HAE). Methods. The present prospective study involved patients with known or suspected CAD referred for myocardial perfusion imaging by single-photon emission computed tomography (SPECT). Twenty patients were included in the study protocol, and scanned using DECT imaging (n = 20). The same pharmacological stress was used for DECT and SPECT scans. Results. A total of 680 left ventricular segments were evaluated by DECT and SPECT. The contrast to noise ratio was 8.8±2.9. The diagnostic performance of DECT was very good in identifying perfusion defects [area under ROC curve (AUC) of DECT 0.90 (0.86-0.94)] compared with SPECT, and remained unaffected when including only segments affected by beam hardening artifacts (BHA) [AUC= DECT 0.90 (0.84-0.96)]. Conclusions. In this pilot investigation, myocardial perfusion assessment by DECT imaging in patients with intermediate to high likelihood of CAD was feasible and remained unaffected by the presence of BHA. (authors) [es

  3. Detectors for high resolution dynamic pet

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.; Huesman, R.H.

    1983-05-01

    This report reviews the motivation for high spatial resolution in dynamic positron emission tomography of the head and the technical problems in realizing this objective. We present recent progress in using small silicon photodiodes to measure the energy deposited by 511 keV photons in small BGO crystals with an energy resolution of 9.4% full-width at half-maximum. In conjunction with a suitable phototube coupled to a group of crystals, the photodiode signal to noise ratio is sufficient for the identification of individual crystals both for conventional and time-of-flight positron tomography

  4. [Myocardial ultrastructural changes in rats following different levels of acute +Gz exposure].

    Science.gov (United States)

    Zheng, Jun; Liu, Cheng-gang; Ren, Li; Xiao, Xiao-guang; Xu, Shu-xuan; Wang, Ping; Ji, Gui-ying

    2004-06-01

    To observe the effects of different levels of acute +Gz exposure on myocardial ultrastructure of rats and provide experimental basis for further development of anti-G measures. Twenty male Wistar rats were randomly divided into 4 groups (n=5): normal control group, +20 Gz group, +10 Gz group and +5 Gz group. Profile of the centrifuge +Gz exposure was trapezoidal, in which +20 Gz lasted for 30 s, +10 Gz for 1.5 min. +5 Gz exposure was repeated for 3 times with 30 min interval and each for 1.5 min. Myocardial tissue of left ventricle was sampled for transmission electron microscopy 5 h after exposure. +20 Gz and +10 Gz exposure caused obvious edema of myocardial and endothelial cells, myofibril disorder and injuries of mitochondria and nucleus. Breaks of myocardial fiber, formation of contraction bands and rupture of mitochondria were also observed in +20 Gz group. In +5 Gz group, there was still slight edema of myocardial and endothelial cells, while organic changes of myocardial ultrastructure were not observed. High +Gz exposure can cause myocardial ultrastructural injury in rats. Slight reversible injured response can also be observed in myocardial cell after repeated moderate level of +Gz exposure. This indicates that attention should be paid to the study of the effect of high +Gz on heart in pilots.

  5. High Spatial Resolution Cardiovascular Magnetic Resonance at 7.0 Tesla in Patients with Hypertrophic Cardiomyopathy – First Experiences: Lesson Learned from 7.0 Tesla

    Science.gov (United States)

    Prothmann, Marcel; von Knobelsdorff-Brenkenhoff, Florian; Töpper, Agnieszka; Dieringer, Matthias A.; Shahid, Etham; Graessl, Andreas; Rieger, Jan; Lysiak, Darius; Thalhammer, C.; Huelnhagen, Till; Kellman, Peter; Niendorf, Thoralf; Schulz-Menger, Jeanette

    2016-01-01

    Background Cardiovascular Magnetic Resonance (CMR) provides valuable information in patients with hypertrophic cardiomyopathy (HCM) based on myocardial tissue differentiation and the detection of small morphological details. CMR at 7.0T improves spatial resolution versus today’s clinical protocols. This capability is as yet untapped in HCM patients. We aimed to examine the feasibility of CMR at 7.0T in HCM patients and to demonstrate its capability for the visualization of subtle morphological details. Methods We screened 131 patients with HCM. 13 patients (9 males, 56 ±31 years) and 13 healthy age- and gender-matched subjects (9 males, 55 ±31years) underwent CMR at 7.0T and 3.0T (Siemens, Erlangen, Germany). For the assessment of cardiac function and morphology, 2D CINE imaging was performed (voxel size at 7.0T: (1.4x1.4x2.5) mm3 and (1.4x1.4x4.0) mm3; at 3.0T: (1.8x1.8x6.0) mm3). Late gadolinium enhancement (LGE) was performed at 3.0T for detection of fibrosis. Results All scans were successful and evaluable. At 3.0T, quantification of the left ventricle (LV) showed similar results in short axis view vs. the biplane approach (LVEDV, LVESV, LVMASS, LVEF) (p = 0.286; p = 0.534; p = 0.155; p = 0.131). The LV-parameters obtained at 7.0T where in accordance with the 3.0T data (pLVEDV = 0.110; pLVESV = 0.091; pLVMASS = 0.131; pLVEF = 0.182). LGE was detectable in 12/13 (92%) of the HCM patients. High spatial resolution CINE imaging at 7.0T revealed hyperintense regions, identifying myocardial crypts in 7/13 (54%) of the HCM patients. All crypts were located in the LGE-positive regions. The crypts were not detectable at 3.0T using a clinical protocol. Conclusions CMR at 7.0T is feasible in patients with HCM. High spatial resolution gradient echo 2D CINE imaging at 7.0T allowed the detection of subtle morphological details in regions of extended hypertrophy and LGE. PMID:26863618

  6. High Resolution Thermometry for EXACT

    Science.gov (United States)

    Panek, J. S.; Nash, A. E.; Larson, M.; Mulders, N.

    2000-01-01

    High Resolution Thermometers (HRTs) based on SQUID detection of the magnetization of a paramagnetic salt or a metal alloy has been commonly used for sub-nano Kelvin temperature resolution in low temperature physics experiments. The main applications to date have been for temperature ranges near the lambda point of He-4 (2.177 K). These thermometers made use of materials such as Cu(NH4)2Br4 *2H2O, GdCl3, or PdFe. None of these materials are suitable for EXACT, which will explore the region of the He-3/He-4 tricritical point at 0.87 K. The experiment requirements and properties of several candidate paramagnetic materials will be presented, as well as preliminary test results.

  7. Evaluation of left ventricular function in patient with old myocardial infarction by 201-thallium myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Kanji; Shimohara, Yasuaki; Ito, Misao; Okada, Keisei [Kure Kyosai Hospital, Hiroshima (Japan); Kodama, Kazunori

    1984-08-01

    Correlation between the ratio of myocardial defect calculated by 201-thallium myocardial scintigraphy and the left ventricular ejection fraction (LVEF) obtained by gated blood pool scintigraphy and the maximum level of creatine phosphokinase (CPK) was studied in 70 patients with old myocardial infarction. There was a significant correlation between the defect ratio and the LVEF or CPK level in patients with anterior or septal myocardial infarction. In all patients with inferior myocardial infarction in whom no defect was seen, the LVEF was more than 40%. However, no distinct correlation between the defect ratio and the LVEF or CPK level was obtained in cases of inferior myocardial infarction.

  8. High temperature and high resolution uv photoelectron spectroscopy using supersonic molecular beams

    International Nuclear Information System (INIS)

    Wang, Lai-Sheng; Reutt-Robey, J.E.; Niu, B.; Lee, Y.T.; Shirley, D.A.

    1989-07-01

    A high temperature molecular beam source with electron bombardment heating has been built for high resolution photoelectron spectroscopic studies of high temperature species and clusters. This source has the advantages of: producing an intense, continuous, seeded molecular beam, eliminating the interference of the heating mechanism from the photoelectron measurement. Coupling the source with our hemispherical electron energy analyzer, we can obtain very high resolution HeIα (584 angstrom) photoelectron spectra of high temperature species. Vibrationally-resolved photoelectron spectra of PbSe, As 2 , As 4 , and ZnCl 2 are shown to demonstrate the performance of the new source. 25 refs., 8 figs., 1 tab

  9. Myocardial accumulation of a dopamine D[sub 2] receptor-binding radioligand, 2'-iodospiperone

    Energy Technology Data Exchange (ETDEWEB)

    Saji, Hideo; Yonekura, Yoshiharu; Tanahashi, Kiyoko; Iida, Yasuhiko; Iwasaki, Yasushi; Magata, Yasuhiro; Konishi, Junji; Yokoyama, Akira [Kyoto Univ. (Japan). Faculty of Medicine

    1993-08-01

    [sup 125]I-iodospiperone (2'-ISP), which has a high and selective affinity for dopamine D[sub 2] receptors, produced a high myocardial accumulation of radioactivity in the early phase after intravenous injection into mice. A human scintigraphic study also showed that the myocardium was clearly visualized soon after intravenous injection of the tracer. Analysis of the myocardial homogenate obtained from mice showed that [sup 125]I-2'-ISP was metabolically stable and was taken up by the myocardium in its intact form. Administration of spiperone significantly reduced the myocardial uptake of [sup 125]I-2'-ISP in mice. Treatment with haloperidol and (+) butaclamol, which have a high affinity for dopamine D[sub 2] receptors, also tended to reduce the myocardial uptake of radioactivity, while (-)-butaclamol, which has no affinity for dopamine D[sub 2] receptors, caused no change in uptake. These findings suggest that the myocardial accumulation of 2'-ISP occurred in association with dopamine D[sub 2] (DA[sub 2]) receptors. (author).

  10. Ribbon scanning confocal for high-speed high-resolution volume imaging of brain.

    Directory of Open Access Journals (Sweden)

    Alan M Watson

    Full Text Available Whole-brain imaging is becoming a fundamental means of experimental insight; however, achieving subcellular resolution imagery in a reasonable time window has not been possible. We describe the first application of multicolor ribbon scanning confocal methods to collect high-resolution volume images of chemically cleared brains. We demonstrate that ribbon scanning collects images over ten times faster than conventional high speed confocal systems but with equivalent spectral and spatial resolution. Further, using this technology, we reconstruct large volumes of mouse brain infected with encephalitic alphaviruses and demonstrate that regions of the brain with abundant viral replication were inaccessible to vascular perfusion. This reveals that the destruction or collapse of large regions of brain micro vasculature may contribute to the severe disease caused by Venezuelan equine encephalitis virus. Visualization of this fundamental impact of infection would not be possible without sampling at subcellular resolution within large brain volumes.

  11. Assessment of myocardial fatty acid metabolism in patients with angina pectoris and diabetes mellitus using 123I-BMIPP myocardial scintigraphy

    International Nuclear Information System (INIS)

    Ito, Kazuki; Tanabe, Takuji; Yuba, Tatsuya; Doue, Tomoki; Adachi, Yoshihiko; Katoh, Shuuji; Sugihara, Hiroki; Azuma, Akihiro; Nakagawa, Masao

    2001-01-01

    We studied the effect of myocardial ischemia and diabetes mellitus (DM) on the myocardial fatty acid metabolism using 123 I-BMIPP myocardial scintigraphy. We performed 123 I-BMIPP myocardial scintigraphy in 50 patients with myocardial ischemia and without DM (AP), in 30 patients with myocardial ischemia and DM (AP+DM), 12 patients with DM and without myocardial ischemia (DM), and in 10 normal subjects (N). Myocardial uptake rate of 123 I-BMIPP was obtained using the time activity curve. Myocardial washout rate of 123 I-BMIPP was calculated using the polar images of early and delayed SPECT images. Myocardial uptake rate of 123 I-BMIPP (%) were AP: 4.9±0.6, AP+DM: 5.5±0.5, DM 5.7±0.5 and N: 5.0±0.4. 123 I-BMIPP myocardial uptake rate was increased in AP+DM and DM. 123 I-BMIPP myocardial washout rate (%) were AP: 30.2±4.3, AP+DM: 24.5±3.9, DM: 16.1±2.8 and N: 19.4±3.2. 123 I-BMIPP myocardial washout rate was increased in AP and AP+DM. 123 I-BMIPP myocardial washout rate was increased particularly in patients with multi-vessels disease. 123 I-BMIPP myocardial washout rate was decreased in DM. The present study suggested that diabetes mellitus increased myocardial fatty acid uptake and decreased myocardial fatty acid washout, and that myocardial ischemia increased myocardial fatty acid washout. (author)

  12. Tumor necrosis factor-alpha increases myocardial microvascular transport in vivo

    DEFF Research Database (Denmark)

    Hansen, P R; Svendsen, Jesper Hastrup; Høyer, S

    1994-01-01

    Tumor necrosis factor-alpha (TNF-alpha) is a primary mediator in the pathogenesis of tissue injury, and high circulating levels of TNF-alpha are found in a variety of pathological conditions. In open-chest anesthetized dogs, the effects of intracoronary recombinant human TNF-alpha (rTNF-alpha; 100...... in cardiac output and was associated with the appearance of areas with myocardial necrosis in the regional left ventricular wall. The myocardial plasma flow rate and maximum plasma flow rate in response to a 30-s coronary occlusion were not influenced by rTNF-alpha, although a decrease in the myocardial...... ng/kg for 60 min) on myocardial microvascular transport of a small hydrophilic indicator was examined by the single-injection, residue-detection method. Intracoronary infusion of rTNF-alpha increased myocardial microvascular transport after 120 min. This increase was preceded by a sustained decline...

  13. Role of myocardial perfusion imaging in evaluating thrombolytic therapy for acute myocardial infarction

    International Nuclear Information System (INIS)

    Beller, G.A.

    1987-01-01

    Myocardial thallium-201 scintigraphy is being increasingly employed as a method for assessing the efficacy of coronary reperfusion in acute myocardial infarction. New thallium uptake after intracoronary tracer administration after successful recanalization indicates that nutrient blood flow has been successfully restored. One may also presume that some myocardial salvage occurred if thallium administered in this manner is transported intracellularly by myocytes with intact sarcolemmal membranes. However, if one injects thallium by way of the intracoronary route immediately after reperfusion, the initial uptake of thallium in reperfused myocardium may predominantly represent hyperemic flow and regional thallium counts measured may not be proportional to the mass of viable myocytes. When thallium is injected intravenously during the occlusion phase the degree of redistribution after thrombolysis is proportional to the degree of flow restoration and myocardial viability. When thallium is injected for the first time intravenously immediately after reperfusion, an overestimation of myocardial salvage may occur because of excess thallium uptake in the infarct zone consequent to significant hyperemia. Another approach to myocardial thallium scintigraphy in patients undergoing thrombolytic therapy is to administer two separate intravenous injections before and 24 hours or later after treatment. Finally, patients with acute myocardial infarction who receive intravenous thrombolytic therapy are candidates for predischarge exercise thallium-201 scintigraphy for risk stratification and detection of residual ischemia

  14. High resolution tsunami inversion for 2010 Chile earthquake

    Directory of Open Access Journals (Sweden)

    T.-R. Wu

    2011-12-01

    Full Text Available We investigate the feasibility of inverting high-resolution vertical seafloor displacement from tsunami waveforms. An inversion method named "SUTIM" (small unit tsunami inversion method is developed to meet this goal. In addition to utilizing the conventional least-square inversion, this paper also enhances the inversion resolution by Grid-Shifting method. A smooth constraint is adopted to gain stability. After a series of validation and performance tests, SUTIM is used to study the 2010 Chile earthquake. Based upon data quality and azimuthal distribution, we select tsunami waveforms from 6 GLOSS stations and 1 DART buoy record. In total, 157 sub-faults are utilized for the high-resolution inversion. The resolution reaches 10 sub-faults per wavelength. The result is compared with the distribution of the aftershocks and waveforms at each gauge location with very good agreement. The inversion result shows that the source profile features a non-uniform distribution of the seafloor displacement. The highly elevated vertical seafloor is mainly concentrated in two areas: one is located in the northern part of the epicentre, between 34° S and 36° S; the other is in the southern part, between 37° S and 38° S.

  15. High resolution tsunami inversion for 2010 Chile earthquake

    Science.gov (United States)

    Wu, T.-R.; Ho, T.-C.

    2011-12-01

    We investigate the feasibility of inverting high-resolution vertical seafloor displacement from tsunami waveforms. An inversion method named "SUTIM" (small unit tsunami inversion method) is developed to meet this goal. In addition to utilizing the conventional least-square inversion, this paper also enhances the inversion resolution by Grid-Shifting method. A smooth constraint is adopted to gain stability. After a series of validation and performance tests, SUTIM is used to study the 2010 Chile earthquake. Based upon data quality and azimuthal distribution, we select tsunami waveforms from 6 GLOSS stations and 1 DART buoy record. In total, 157 sub-faults are utilized for the high-resolution inversion. The resolution reaches 10 sub-faults per wavelength. The result is compared with the distribution of the aftershocks and waveforms at each gauge location with very good agreement. The inversion result shows that the source profile features a non-uniform distribution of the seafloor displacement. The highly elevated vertical seafloor is mainly concentrated in two areas: one is located in the northern part of the epicentre, between 34° S and 36° S; the other is in the southern part, between 37° S and 38° S.

  16. Reproducibility and quantitativity of oblique-angle reconstruction in single photon emission computed tomography using Tl-201 myocardial phantom

    International Nuclear Information System (INIS)

    Bunko, Hisashi; Nanbu, Ichiro; Seki, Hiroyasu

    1984-01-01

    This study was carried out in order to evaluate reproducibility and quantitativity of oblique-angle reconstruction of myocardial phantom SPECT. Myocardial phantom with transmural and subendcardial defects, and off-axis phantom with wall thickness changing continuously from 0 to 23 mm were used. Sixty projection data in every 6 0 were aquired using dual-camera (ZLC) with high resolution collimators connected to Scintipac-2400 computer system. Oblique-angle reconstructed images were obtained by indicating the long axis of the phantom manually in the transaxial and vertical long axial tomograms. Reproducibility and quantitativity were evaluated by creating circumferential profile (CFP) of the finally reconstructed short axial images. Inter- and intra-operater reproducibility of relative counting ratio were less than 6.7% (C.V.) and 3.3% (C.V.), respectively. Both inter- and intraoperater reproducibility of absolute counts were better than that of counting ratio (less than 5.1% (C.V.) and 2.9% (C.V.), respectively). Variation of defect location in the reconstructed image and between the slices were less than 1 sampling interval of CFP (6 0 ) and 0.6 slice, respectively. Quantitativity of counts in the reconstructed images was poor in the transmulal defect, but was fair in the subendocardial defect. Counting ratio was greatly affected by wall thickness. Temporal quantitatibity or linearity of the counts in sequential SPECTs was good in non-defect area, especially when wall thickness was greater than 70% (16 mm) of maximum. In conclusion, three-dimensional oblique-angle reconstruction in Tl-201 myocardial SPECT could be applicable to relative and temporal quantitation of local myocardial activity other than defect area for the quantitative evaluation of Tl-201 myocardial wash-out. (J.P.N.)

  17. Concept for a new high resolution high intensity diffractometer

    Energy Technology Data Exchange (ETDEWEB)

    Stuhr, U [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    A concept of a new time-of-flight powder-diffractometer for a thermal neutral beam tube at SINQ is presented. The design of the instrument optimises the contradictory conditions of high intensity and high resolution. The high intensity is achieved by using many neutron pulses simultaneously. By analysing the time-angle-pattern of the detected neutrons an assignment of the neutrons to a single pulse is possible. (author) 3 figs., tab., refs.

  18. The relationship between myocardial blood flow and myocardial viability after reperfusion. Myocardial viability assessed by [sup 15]O-water-PET

    Energy Technology Data Exchange (ETDEWEB)

    Tsukagoshi, Joichi (Gunma Univ., Maebashi (Japan). School of Medicine)

    1994-09-01

    The purpose of this study was to examine the relationship between myocardial blood flow and myocardial viability in the ischemic canine myocardium after reperfusion. Transient ischemia was induced by 60-, 90-, and 180-minute occlusion of the left anterior descending coronary artery. Myocardial blood flow (MBF) was measured in the areas in which regional contractility was severely impaired (ehocardiographically akinetic or dyskinetic) in the early reperfusion period by [sup 15]O-water positron emission tomography (PET) 12 hours and 4 weeks after reperfusion. An MBF ratio of ischemic to nonischemic regions 12 hours after reperfusion was inversely correlated with the amount of histologically determined tissue necrosis (r=-0.74). The regional contractility recovered 4 weeks later in the areas where an MBF ratio was 0.48 or greater, but did not recover in the areas with a lower MBF ratio. Thus, myocardial viability can be appropriately predicted in the early phase of myocardial perfusion by PET with [sup 15]O-water even in the absence of metabolic imaging. (author).

  19. Quantitative myocardial perfusion PET parametric imaging at the voxel-level

    International Nuclear Information System (INIS)

    Mohy-ud-Din, Hassan; Rahmim, Arman; Lodge, Martin A

    2015-01-01

    Quantitative myocardial perfusion (MP) PET has the potential to enhance detection of early stages of atherosclerosis or microvascular dysfunction, characterization of flow-limiting effects of coronary artery disease (CAD), and identification of balanced reduction of flow due to multivessel stenosis. We aim to enable quantitative MP-PET at the individual voxel level, which has the potential to allow enhanced visualization and quantification of myocardial blood flow (MBF) and flow reserve (MFR) as computed from uptake parametric images. This framework is especially challenging for the 82 Rb radiotracer. The short half-life enables fast serial imaging and high patient throughput; yet, the acquired dynamic PET images suffer from high noise-levels introducing large variability in uptake parametric images and, therefore, in the estimates of MBF and MFR. Robust estimation requires substantial post-smoothing of noisy data, degrading valuable functional information of physiological and pathological importance. We present a feasible and robust approach to generate parametric images at the voxel-level that substantially reduces noise without significant loss of spatial resolution. The proposed methodology, denoted physiological clustering, makes use of the functional similarity of voxels to penalize deviation of voxel kinetics from physiological partners. The results were validated using extensive simulations (with transmural and non-transmural perfusion defects) and clinical studies. Compared to post-smoothing, physiological clustering depicted enhanced quantitative noise versus bias performance as well as superior recovery of perfusion defects (as quantified by CNR) with minimal increase in bias. Overall, parametric images obtained from the proposed methodology were robust in the presence of high-noise levels as manifested in the voxel time-activity-curves. (paper)

  20. Myocardial scintigraphy with thallium-201

    Energy Technology Data Exchange (ETDEWEB)

    Lichte, H [Zentralkrankenhaus Gauting (Germany, F.R.). Nuklearmedizinische Abt.

    1977-04-01

    Myocardial scintigraphy with /sup 201/thallium is a non-invasive method for detection of myocardial infarction and coronary heart disease. Redistribution-analysis as a sequential-scintigraphy of an exercise-scan permits to distinguish between myocardial scars and coronary vessel disease.

  1. Volumetric expiratory high-resolution CT of the lung

    International Nuclear Information System (INIS)

    Nishino, Mizuki; Hatabu, Hiroto

    2004-01-01

    We developed a volumetric expiratory high-resolution CT (HRCT) protocol that provides combined inspiratory and expiratory volumetric imaging of the lung without increasing radiation exposure, and conducted a preliminary feasibility assessment of this protocol to evaluate diffuse lung disease with small airway abnormalities. The volumetric expiratory high-resolution CT increased the detectability of the conducting airway to the areas of air trapping (P<0.0001), and added significant information about extent and distribution of air trapping (P<0.0001)

  2. Developing Visual Editors for High-Resolution Haptic Patterns

    DEFF Research Database (Denmark)

    Cuartielles, David; Göransson, Andreas; Olsson, Tony

    2012-01-01

    In this article we give an overview of our iterative work in developing visual editors for creating high resolution haptic patterns to be used in wearable, haptic feedback devices. During the past four years we have found the need to address the question of how to represent, construct and edit high...... resolution haptic patterns so that they translate naturally to the user’s haptic experience. To solve this question we have developed and tested several visual editors...

  3. Myocardial Lipid Profiling During Time Course of High Fat Diet and its Relationship to the Expression of Fatty Acid Transporters

    Directory of Open Access Journals (Sweden)

    Ewa Harasim

    2015-09-01

    Full Text Available Background/Aims: It is well documented that increased fatty acids (FA supply causes lipid accumulation and insulin resistance in skeletal muscles. Whether the same mechanism is present in the heart is still unclear. Therefore, the goal of our study was to determine the content of specific myocardial lipid fractions during feeding rats a high fat diet (HFD for 5 weeks. Moreover, the relation between changes in myocardial lipid content, whole body insulin resistance and the expression of fatty acid transporters in each week of HFD was established. Methods: Gas liquid chromatography and high performance liquid chromatography were used to determine the content of lipid fractions in the left ventricle. Expression of selected proteins was estimated by Western blot technique. All measurements were made after each week of HFD. Results: As expected, lipid profile in myocardium was altered by HFD in different weeks of the study with the most intense changes in triacylglycerols, long chain fatty acid-CoA and ceramide. Furthermore, there was a significant elevation of plasmalemmal (the 4th and the 5th week and mitochondrial expression (from the 3rd to the 5th week of fatty acid translocase. Conclusion: High fat diet affects myocardial lipid profile in each week of its duration and causes alternations in FA metabolism in cardiomyocytes.

  4. CT imaging of myocardial perfusion and viability. Beyond structure and function

    Energy Technology Data Exchange (ETDEWEB)

    Schoepf, U. Joseph [Medical University of South Carolina, Charleston, SC (United States). Dept. of Radiology and Radiological Sciences; Bamberg, Fabian [Muenchen Univ. (Germany); Bastarrika, Gorka [Sunnybrook Health Sciences Centre, Toronto, ON (Canada). Cardiothoracic Imaging Division; Ruzsics, Balazs [Royal Liverpool and Broadgreen Univ., Liverpool (United Kingdom). Dept. of Cardiology; Vliegenthart, Rozemarijn (ed.) [University Medical Center Groningen (Netherlands). Center for Medical Imaging

    2014-06-01

    First publication to be devoted to the subject. Reviews an advanced, promising application in healthcare. Spans multiple medical disciplines. The rapid evolution in cardiac computed tomography during the past decade has improved spatial and temporal resolution to the extent that cardiac CT is now an accepted alternative for the non-invasive interrogation of the heart. Beyond the assessment of cardiac structure and ventricular function, recent research has identified yet another promising CT application for the comprehensive diagnosis of coronary heart disease, namely the assessment of myocardial perfusion and viability. In this book, the first to be devoted to this novel application of CT, leading experts from across the world present up-to-date information and consider future directions. After short sections outlining the state of the art in the traditional applications of CT to image structure and function, the full range of CT techniques that may be employed to evaluate the myocardial blood supply are discussed in detail. Similarly, diverse CT approaches for the assessment of myocardial viability are described, with careful consideration of the available experimental and clinical evidence and the role of quantitative imaging.

  5. High resolution SETI: Experiences and prospects

    Science.gov (United States)

    Horowitz, Paul; Clubok, Ken

    Megachannel spectroscopy with sub-Hertz resolution constitutes an attractive strategy for a microwave search for extraterrestrial intelligence (SETI), assuming the transmission of a narrowband radiofrequency beacon. Such resolution matches the properties of the interstellar medium, and the necessary Doppler corrections provide a high degree of interference rejection. We have constructed a frequency-agile receiver with an FFT-based 8 megachannel digital spectrum analyzer, on-line signal recognition, and multithreshold archiving. We are using it to conduct a meridian transit search of the northern sky at the Harvard-Smithsonian 26-m antenna, with a second identical system scheduled to begin observations in Argentina this month. Successive 400 kHz spectra, at 0.05 Hz resolution, are searched for features characteristic of an intentional narrowband beacon transmission. These spectra are centered on guessable frequencies (such as λ21 cm), referenced successively to the local standard of rest, the galactic barycenter, and the cosmic blackbody rest frame. This search has rejected interference admirably, but is greatly limited both in total frequency coverage and sensitivity to signals other than carriers. We summarize five years of high resolution SETI at Harvard, in the context of answering the questions "How useful is narrowband SETI, how serious are its limitations, what can be done to circumvent them, and in what direction should SETI evolve?" Increasingly powerful signal processing hardware, combined with ever-higher memory densities, are particularly relevant, permitting the construction of compact and affordable gigachannel spectrum analyzers covering hundreds of megahertz of instantaneous bandwidth.

  6. The high-resolution regional reanalysis COSMO-REA6

    Science.gov (United States)

    Ohlwein, C.

    2016-12-01

    Reanalyses gain more and more importance as a source of meteorological information for many purposes and applications. Several global reanalyses projects (e.g., ERA, MERRA, CSFR, JMA9) produce and verify these data sets to provide time series as long as possible combined with a high data quality. Due to a spatial resolution down to 50-70km and 3-hourly temporal output, they are not suitable for small scale problems (e.g., regional climate assessment, meso-scale NWP verification, input for subsequent models such as river runoff simulations). The implementation of regional reanalyses based on a limited area model along with a data assimilation scheme is able to generate reanalysis data sets with high spatio-temporal resolution. Within the Hans-Ertel-Centre for Weather Research (HErZ), the climate monitoring branch concentrates efforts on the assessment and analysis of regional climate in Germany and Europe. In joint cooperation with DWD (German Meteorological Service), a high-resolution reanalysis system based on the COSMO model has been developed. The regional reanalysis for Europe matches the domain of the CORDEX EURO-11 specifications, albeit at a higher spatial resolution, i.e., 0.055° (6km) instead of 0.11° (12km) and comprises the assimilation of observational data using the existing nudging scheme of COSMO complemented by a special soil moisture analysis with boundary conditions provided by ERA-Interim data. The reanalysis data set covers the past 20 years. Extensive evaluation of the reanalysis is performed using independent observations with special emphasis on precipitation and high-impact weather situations indicating a better representation of small scale variability. Further, the evaluation shows an added value of the regional reanalysis with respect to the forcing ERA Interim reanalysis and compared to a pure high-resolution dynamical downscaling approach without data assimilation.

  7. Assessment of myocardial viability using multidetector computed tomography in patients with reperfused acute myocardial infarction

    International Nuclear Information System (INIS)

    Kim, T.; Choi, B.J.; Kang, D.K.; Sun, J.S.

    2012-01-01

    Aim: To assess the prognostic value of 64-section multidetector computed tomography (MDCT) to predict follow-up myocardial dysfunction and functional recovery after reperfusion therapy in patients with acute myocardial infarction (MI) as defined by echocardiography. Materials and methods: After reperfusion therapy for acute MI, 71 patients underwent two-phase contrast-enhanced MDCT and follow-up echocardiography. MDCT findings were compared with echocardiographic findings using kappa statistics. The areas under the receiver operating characteristic curves (AUCs) and the odds ratios (ORs) of early perfusion defects (EPD), delayed enhancement (DE), and residual perfusion defects (RPD) for predicting follow-up myocardial dysfunction and functional recovery were calculated on a segmental basis. Results: The presence of transmural EPD (EPD TM ) or RPD showed good agreement (k = 0.611 and 0.658, respectively) with follow-up myocardial dysfunction, while subendocardial EPD (EPD sub ) or subendocardial DE (DE sub ) showed fair agreement with follow-up myocardial dysfunction (k = 0.235 and 0.234, respectively). The AUC of RPD (0.796) was superior (p TM (0.761) and DE TM (0.771). The presence of EPD TM , DE TM , and RPD were significant, independent positive predictors of follow-up myocardial dysfunction (OR = 6.4, 1.9, and 9.8, respectively). EPD TM was a significant, independent negative predictor of myocardial functional recovery (OR = 0.13). Conclusion: Abnormal myocardial attenuation on two-phase MDCT after reperfusion therapy may provide promising information regarding myocardial viability in patients with acute MI.

  8. Monitoring of myocardial edema following acute myocardial infarction

    International Nuclear Information System (INIS)

    Tahir, E.; Sinn, M.; Avanesov, M.; Wien, J.; Saering, D.; Stehning, C.; Radunski, U. K.; Muellerleile, K.; Adam, G.; Lund, G. K.

    2015-01-01

    normal myocardium with 1018 ± 43 ms and remained constantly high in the edema zone throughout all follow-ups. Edema size continuously decreased within the following months after acute myocardial infarction, but was still present after 6 months in all patients. Additionally, quantitative mapping show increased T1 and T2 values within the edema zone indicating prolonged presence of edema up to 6 months after infarction

  9. Early spontaneous intermittent myocardial reperfusion during acute myocardial infarction is associated with augmented thrombogenic activity and less myocardial damage

    NARCIS (Netherlands)

    Haider, A.W.; Andreotti, F.; Hackett, D.R.; Tousoulis, D.; Kluft, C.; Maseri, A.; Davies, G.J.

    1995-01-01

    Objectives. This study investigated the influence of early spontaneous intermittent reperfusion on the extent of myocardial damage and its relation to endogenous hemostatic activity, Background. In the early phase of acute myocardial infarction coronary occlusion is often intermittent, even before

  10. Myocardial adrenergic nerve activity in valvular diseases assessed by iodine-123-metaiodobenzylguanidine myocardial scintigraphy

    International Nuclear Information System (INIS)

    Imamura, Yoshihiro; Fukuyama, Takaya

    1997-01-01

    Iodine-123-metaiodobenzylguanidine (MIBG) imaging was used to assess myocardial adrenergic nerve activity in patients with heart failure. MIBG planar images were obtained in 94 patients. The uptake of MIBG, calculated as the heart-to-mediastinum activity ratio in the immediate image (15 min), showed a significant decrease only in patients with severe heart failure due to cardiomyopathy, but was not changed in those with valvular diseases. Storage and release of MIBG, calculated as the percentage myocardial MIBG washout from 15 min to 4 hours after isotope injection, was substantially accelerated in both patients with cardiomyopathy and valvular diseases in proportion to the severity of heart failure. These data suggest that, in severe heart failure associated with cardiomyopathy, norepinephrine uptake is reduced. Also, myocardial adrenergic nerve activity is accelerated in proportion to the severity of heart failure independent of the underlying cause. MIBG images were analyzed in 20 patients with mitral stenosis with the same methods to clarify whether myocardial adrenergic nerve activity is different in patients with heart failure without left ventricular volume or pressure overload. Myocardial uptake of MIBG did not show any significant difference. The percentage myocardial MIBG washout was increased in patients with severe heart failure. The closest correlation was between myocardial washout and cardiac output. In heart failure due to mitral stenosis, myocardial adrenergic nerve activity is intensified. Decrease in cardiac output associated with mitral stenosis acts as a potent stimulus for this intensification. (author)

  11. SRS station 16.3: high-resolution applications

    CERN Document Server

    Murphy, B M; Golshan, M; Moore, M; Reid, J; Kowalski, G

    2001-01-01

    Station 16.3 is a high-resolution X-ray diffraction beamline at Daresbury Laboratory Synchrotron Radiation Source. The data presented demonstrate the high-resolution available on the station utilising the recently commissioned four-reflection Si 1 1 1 monochromator and three-reflection Si 1 1 1 analyser. For comparison, a reciprocal space map of the two-bounce Si 1 1 1 monochromator and two-bounce analyser is also shown. Operation of the station is illustrated with examples for silicon, and for diamond. Lattice parameter variations were measured with accuracies in the part per million range and lattice tilts at the arc second level (DuMond, Phys. Rev. 52 (1937) 872).

  12. High-resolution X-ray crystal structure of bovine H-protein using the high-pressure cryocooling method.

    Science.gov (United States)

    Higashiura, Akifumi; Ohta, Kazunori; Masaki, Mika; Sato, Masaru; Inaka, Koji; Tanaka, Hiroaki; Nakagawa, Atsushi

    2013-11-01

    Recently, many technical improvements in macromolecular X-ray crystallography have increased the number of structures deposited in the Protein Data Bank and improved the resolution limit of protein structures. Almost all high-resolution structures have been determined using a synchrotron radiation source in conjunction with cryocooling techniques, which are required in order to minimize radiation damage. However, optimization of cryoprotectant conditions is a time-consuming and difficult step. To overcome this problem, the high-pressure cryocooling method was developed (Kim et al., 2005) and successfully applied to many protein-structure analyses. In this report, using the high-pressure cryocooling method, the X-ray crystal structure of bovine H-protein was determined at 0.86 Å resolution. Structural comparisons between high- and ambient-pressure cryocooled crystals at ultra-high resolution illustrate the versatility of this technique. This is the first ultra-high-resolution X-ray structure obtained using the high-pressure cryocooling method.

  13. Resolution-recovery-embedded image reconstruction for a high-resolution animal SPECT system.

    Science.gov (United States)

    Zeraatkar, Navid; Sajedi, Salar; Farahani, Mohammad Hossein; Arabi, Hossein; Sarkar, Saeed; Ghafarian, Pardis; Rahmim, Arman; Ay, Mohammad Reza

    2014-11-01

    The small-animal High-Resolution SPECT (HiReSPECT) is a dedicated dual-head gamma camera recently designed and developed in our laboratory for imaging of murine models. Each detector is composed of an array of 1.2 × 1.2 mm(2) (pitch) pixelated CsI(Na) crystals. Two position-sensitive photomultiplier tubes (H8500) are coupled to each head's crystal. In this paper, we report on a resolution-recovery-embedded image reconstruction code applicable to the system and present the experimental results achieved using different phantoms and mouse scans. Collimator-detector response functions (CDRFs) were measured via a pixel-driven method using capillary sources at finite distances from the head within the field of view (FOV). CDRFs were then fitted by independent Gaussian functions. Thereafter, linear interpolations were applied to the standard deviation (σ) values of the fitted Gaussians, yielding a continuous map of CDRF at varying distances from the head. A rotation-based maximum-likelihood expectation maximization (MLEM) method was used for reconstruction. A fast rotation algorithm was developed to rotate the image matrix according to the desired angle by means of pre-generated rotation maps. The experiments demonstrated improved resolution utilizing our resolution-recovery-embedded image reconstruction. While the full-width at half-maximum (FWHM) radial and tangential resolution measurements of the system were over 2 mm in nearly all positions within the FOV without resolution recovery, reaching around 2.5 mm in some locations, they fell below 1.8 mm everywhere within the FOV using the resolution-recovery algorithm. The noise performance of the system was also acceptable; the standard deviation of the average counts per voxel in the reconstructed images was 6.6% and 8.3% without and with resolution recovery, respectively. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  14. High-resolution electron microscopy of advanced materials

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, T.E.; Kung, H.H.; Sickafus, K.E.; Gray, G.T. III; Field, R.D.; Smith, J.F. [Los Alamos National Lab., NM (United States). Materials Science and Technology Div.

    1997-11-01

    This final report chronicles a three-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The High-Resolution Electron Microscopy Facility has doubled in size and tripled in quality since the beginning of the three-year period. The facility now includes a field-emission scanning electron microscope, a 100 kV field-emission scanning transmission electron microscope (FE-STEM), a 300 kV field-emission high-resolution transmission electron microscope (FE-HRTEM), and a 300 kV analytical transmission electron microscope. A new orientation imaging microscope is being installed. X-ray energy dispersive spectrometers for chemical analysis are available on all four microscopes; parallel electron energy loss spectrometers are operational on the FE-STEM and FE-HRTEM. These systems enable evaluation of local atomic bonding, as well as chemical composition in nanometer-scale regions. The FE-HRTEM has a point-to-point resolution of 1.6 {angstrom}, but the resolution can be pushed to its information limit of 1 {angstrom} by computer reconstruction of a focal series of images. HRTEM has been used to image the atomic structure of defects such as dislocations, grain boundaries, and interfaces in a variety of materials from superconductors and ferroelectrics to structural ceramics and intermetallics.

  15. High Resolution PET with 250 micrometer LSO Detectors and Adaptive Zoom

    International Nuclear Information System (INIS)

    Cherry, Simon R.; Qi, Jinyi

    2012-01-01

    There have been impressive improvements in the performance of small-animal positron emission tomography (PET) systems since their first development in the mid 1990s, both in terms of spatial resolution and sensitivity, which have directly contributed to the increasing adoption of this technology for a wide range of biomedical applications. Nonetheless, current systems still are largely dominated by the size of the scintillator elements used in the detector. Our research predicts that developing scintillator arrays with an element size of 250 (micro)m or smaller will lead to an image resolution of 500 (micro)m when using 18F- or 64Cu-labeled radiotracers, giving a factor of 4-8 improvement in volumetric resolution over the highest resolution research systems currently in existence. This proposal had two main objectives: (i) To develop and evaluate much higher resolution and efficiency scintillator arrays that can be used in the future as the basis for detectors in a small-animal PET scanner where the spatial resolution is dominated by decay and interaction physics rather than detector size. (ii) To optimize one such high resolution, high sensitivity detector and adaptively integrate it into the existing microPET II small animal PET scanner as a 'zoom-in' detector that provides higher spatial resolution and sensitivity in a limited region close to the detector face. The knowledge gained from this project will provide valuable information for building future PET systems with a complete ring of very high-resolution detector arrays and also lay the foundations for utilizing high-resolution detectors in combination with existing PET systems for localized high-resolution imaging.

  16. Achieving High Resolution Timer Events in Virtualized Environment.

    Science.gov (United States)

    Adamczyk, Blazej; Chydzinski, Andrzej

    2015-01-01

    Virtual Machine Monitors (VMM) have become popular in different application areas. Some applications may require to generate the timer events with high resolution and precision. This however may be challenging due to the complexity of VMMs. In this paper we focus on the timer functionality provided by five different VMMs-Xen, KVM, Qemu, VirtualBox and VMWare. Firstly, we evaluate resolutions and precisions of their timer events. Apparently, provided resolutions and precisions are far too low for some applications (e.g. networking applications with the quality of service). Then, using Xen virtualization we demonstrate the improved timer design that greatly enhances both the resolution and precision of achieved timer events.

  17. Compact and high-resolution optical orbital angular momentum sorter

    Directory of Open Access Journals (Sweden)

    Chenhao Wan

    2017-03-01

    Full Text Available A compact and high-resolution optical orbital angular momentum (OAM sorter is proposed and demonstrated. The sorter comprises a quadratic fan-out mapper and a dual-phase corrector positioned in the pupil plane and the Fourier plane, respectively. The optical system is greatly simplified compared to previous demonstrations of OAM sorting, and the performance in resolution and efficiency is maintained. A folded configuration is set up using a single reflective spatial light modulator (SLM to demonstrate the validity of the scheme. The two phase elements are implemented on the left and right halves of the SLM and connected by a right-angle prism. Experimental results demonstrate the high resolution of the compact OAM sorter, and the current limit in efficiency can be overcome by replacing with transmissive SLMs and removing the beam splitters. This novel scheme paves the way for the miniaturization and integration of high-resolution OAM sorters.

  18. Myocardial Hemorrhage After Acute Reperfused ST-Segment–Elevation Myocardial Infarction

    Science.gov (United States)

    Carrick, David; Haig, Caroline; Ahmed, Nadeem; McEntegart, Margaret; Petrie, Mark C.; Eteiba, Hany; Hood, Stuart; Watkins, Stuart; Lindsay, M. Mitchell; Davie, Andrew; Mahrous, Ahmed; Mordi, Ify; Rauhalammi, Samuli; Sattar, Naveed; Welsh, Paul; Radjenovic, Aleksandra; Ford, Ian; Oldroyd, Keith G.

    2016-01-01

    Background— The success of coronary reperfusion therapy in ST-segment–elevation myocardial infarction (MI) is commonly limited by failure to restore microvascular perfusion. Methods and Results— We performed a prospective cohort study in patients with reperfused ST-segment–elevation MI who underwent cardiac magnetic resonance 2 days (n=286) and 6 months (n=228) post MI. A serial imaging time-course study was also performed (n=30 participants; 4 cardiac magnetic resonance scans): 4 to 12 hours, 2 days, 10 days, and 7 months post reperfusion. Myocardial hemorrhage was taken to represent a hypointense infarct core with a T2* value of hemorrhage 2 days post MI was associated with clinical characteristics indicative of MI severity and inflammation. Myocardial hemorrhage was a multivariable associate of adverse remodeling (odds ratio [95% confidence interval]: 2.64 [1.07–6.49]; P=0.035). Ten (4%) patients had a cardiovascular cause of death or experienced a heart failure event post discharge, and myocardial hemorrhage, but not microvascular obstruction, was associated with this composite adverse outcome (hazard ratio, 5.89; 95% confidence interval, 1.25–27.74; P=0.025), including after adjustment for baseline left ventricular end-diastolic volume. In the serial imaging time-course study, myocardial hemorrhage occurred in 7 (23%), 13 (43%), 11 (33%), and 4 (13%) patients 4 to 12 hours, 2 days, 10 days, and 7 months post reperfusion. The amount of hemorrhage (median [interquartile range], 7.0 [4.9–7.5]; % left ventricular mass) peaked on day 2 (Phemorrhage and microvascular obstruction follow distinct time courses post ST-segment–elevation MI. Myocardial hemorrhage was more closely associated with adverse outcomes than microvascular obstruction. Clinical Trial Registration— URL: http://www.clinicaltrials.gov. Unique identifier: NCT02072850. PMID:26763281

  19. High resolution manometry findings in patients with esophageal epiphrenic diverticula.

    Science.gov (United States)

    Vicentine, Fernando P P; Herbella, Fernando A M; Silva, Luciana C; Patti, Marco G

    2011-12-01

    The pathophysiology of esophageal epiphrenic diverticula is still uncertain even though a concomitant motility disorder is found in the majority of patients in different series. High resolution manometry may allow detection of motor abnormalities in a higher number of patients with esophageal epiphrenic diverticula compared with conventional manometry. This study aims to evaluate the high resolution manometry findings in patients with esophageal epiphrenic diverticula. Nine individuals (mean age 63 ± 10 years, 4 females) with esophageal epiphrenic diverticula underwent high resolution manometry. A single diverticulum was observed in eight patients and multiple diverticula in one. Visual analysis of conventional tracings and color pressure plots for identification of segmental abnormalities was performed by two researchers experienced in high resolution manometry. Upper esophageal sphincter was normal in all patients. Esophageal body was abnormal in eight patients; lower esophageal sphincter was abnormal in seven patients. Named esophageal motility disorders were found in seven patients: achalasia in six, diffuse esophageal spasm in one. In one patient, a segmental hypercontractile zone was noticed with pressure of 196 mm Hg. High resolution manometry demonstrated motor abnormalities in all patients with esophageal epiphrenic diverticula.

  20. Influence of Respiratory Gating, Image Filtering, and Animal Positioning on High-Resolution Electrocardiography-Gated Murine Cardiac Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chao Wu

    2015-01-01

    Full Text Available Cardiac parameters obtained from single-photon emission computed tomographic (SPECT images can be affected by respiratory motion, image filtering, and animal positioning. We investigated the influence of these factors on ultra-high-resolution murine myocardial perfusion SPECT. Five mice were injected with 99m technetium (99mTc-tetrofosmin, and each was scanned in supine and prone positions in a U-SPECT-II scanner with respiratory and electrocardiographic (ECG gating. ECG-gated SPECT images were created without applying respiratory motion correction or with two different respiratory motion correction strategies. The images were filtered with a range of three-dimensional gaussian kernels, after which end-diastolic volumes (EDVs, end-systolic volumes (ESVs, and left ventricular ejection fractions were calculated. No significant differences in the measured cardiac parameters were detected when any strategy to reduce or correct for respiratory motion was applied, whereas big differences (> 5% in EDV and ESV were found with regard to different positioning of animals. A linear relationship (p < .001 was found between the EDV or ESV and the kernel size of the gaussian filter. In short, respiratory gating did not significantly affect the cardiac parameters of mice obtained with ultra-high-resolution SPECT, whereas the position of the animals and the image filters should be the same in a comparative study with multiple scans to avoid systematic differences in measured cardiac parameters.

  1. Constraining Stochastic Parametrisation Schemes Using High-Resolution Model Simulations

    Science.gov (United States)

    Christensen, H. M.; Dawson, A.; Palmer, T.

    2017-12-01

    Stochastic parametrisations are used in weather and climate models as a physically motivated way to represent model error due to unresolved processes. Designing new stochastic schemes has been the target of much innovative research over the last decade. While a focus has been on developing physically motivated approaches, many successful stochastic parametrisation schemes are very simple, such as the European Centre for Medium-Range Weather Forecasts (ECMWF) multiplicative scheme `Stochastically Perturbed Parametrisation Tendencies' (SPPT). The SPPT scheme improves the skill of probabilistic weather and seasonal forecasts, and so is widely used. However, little work has focused on assessing the physical basis of the SPPT scheme. We address this matter by using high-resolution model simulations to explicitly measure the `error' in the parametrised tendency that SPPT seeks to represent. The high resolution simulations are first coarse-grained to the desired forecast model resolution before they are used to produce initial conditions and forcing data needed to drive the ECMWF Single Column Model (SCM). By comparing SCM forecast tendencies with the evolution of the high resolution model, we can measure the `error' in the forecast tendencies. In this way, we provide justification for the multiplicative nature of SPPT, and for the temporal and spatial scales of the stochastic perturbations. However, we also identify issues with the SPPT scheme. It is therefore hoped these measurements will improve both holistic and process based approaches to stochastic parametrisation. Figure caption: Instantaneous snapshot of the optimal SPPT stochastic perturbation, derived by comparing high-resolution simulations with a low resolution forecast model.

  2. High-resolution flood modeling of urban areas using MSN_Flood

    Directory of Open Access Journals (Sweden)

    Michael Hartnett

    2017-07-01

    Full Text Available Although existing hydraulic models have been used to simulate and predict urban flooding, most of these models are inadequate due to the high spatial resolution required to simulate flows in urban floodplains. Nesting high-resolution subdomains within coarser-resolution models is an efficient solution for enabling simultaneous calculation of flooding due to tides, surges, and high river flows. MSN_Flood has been developed to incorporate moving boundaries around nested domains, permitting alternate flooding and drying along the boundary and in the interior of the domain. Ghost cells adjacent to open boundary cells convert open boundaries, in effect, into internal boundaries. The moving boundary may be multi-segmented and non-continuous, with recirculating flow across the boundary. When combined with a bespoke adaptive interpolation scheme, this approach facilitates a dynamic internal boundary. Based on an alternating-direction semi-implicit finite difference scheme, MSN_Flood was used to hindcast a major flood event in Cork City resulting from the combined pressures of fluvial, tidal, and storm surge processes. The results show that the model is computationally efficient, as the 2-m high-resolution nest is used only in the urban flooded region. Elsewhere, lower-resolution nests are used. The results also show that the model is highly accurate when compared with measured data. The model is capable of incorporating nested sub-domains when the nested boundary is multi-segmented and highly complex with lateral gradients of elevation and velocities. This is a major benefit when modelling urban floodplains at very high resolution.

  3. Collimator optimization in myocardial perfusion SPECT using the ideal observer and realistic background variability for lesion detection and joint detection and localization tasks

    Science.gov (United States)

    Ghaly, Michael; Du, Yong; Links, Jonathan M.; Frey, Eric C.

    2016-03-01

    computed for both tasks and analyzed using ROC and LROC analysis methodologies. The results of this study suggest that collimators with somewhat poorer resolution and higher sensitivity than those of a typical low-energy high-resolution (LEHR) collimator were optimal for both defect detection and joint detection and localization tasks in myocardial perfusion SPECT for the range of defect sizes investigated. This study also indicates that optimizing instrumentation for a detection task may provide near-optimal performance on the more challenging detection-localization task.

  4. VO(2peak), myocardial hypertrophy, and myocardial blood flow in endurance-trained men.

    Science.gov (United States)

    Laaksonen, Marko S; Heinonen, Ilkka; Luotolahti, Matti; Knuuti, Juhani; Kalliokoski, Kari K

    2014-08-01

    Endurance training induces cardiovascular and metabolic adaptations, leading to enhanced endurance capacity and exercise performance. Previous human studies have shown contradictory results in functional myocardial vascular adaptations to exercise training, and we hypothesized that this may be related to different degrees of hypertrophy in the trained heart. We studied the interrelationships between peak aerobic power (V˙O2peak), myocardial blood flow (MBF) at rest and during adenosine-induced vasodilation, and parameters of myocardial hypertrophy in endurance-trained (ET, n = 31) and untrained (n = 17) subjects. MBF and myocardial hypertrophy were studied using positron emission tomography and echocardiography, respectively. Both V˙O2peak (P negatively with adenosine-stimulated MBF, but when LV mass was taken into account as a partial correlate, this correlation disappeared. The present results show that increased LV mass in ET subjects explains the reduced hyperemic myocardial perfusion in this subject population and suggests that excessive LV hypertrophy has negative effect on cardiac blood flow capacity.

  5. Reproducible high-resolution multispectral image acquisition in dermatology

    Science.gov (United States)

    Duliu, Alexandru; Gardiazabal, José; Lasser, Tobias; Navab, Nassir

    2015-07-01

    Multispectral image acquisitions are increasingly popular in dermatology, due to their improved spectral resolution which enables better tissue discrimination. Most applications however focus on restricted regions of interest, imaging only small lesions. In this work we present and discuss an imaging framework for high-resolution multispectral imaging on large regions of interest.

  6. Intracoronary and systemic melatonin to patients with acute myocardial infarction

    DEFF Research Database (Denmark)

    Halladin, Natalie L; Busch, Sarah Ekeløf; Jensen, Svend Eggert

    2014-01-01

    -point is the Myocardial Salvage Index assessed by cardiovascular magnetic resonance imaging on day 4 (± 1) after pPCI. The secondary end-points are high-sensitivity troponin, creatinekinase myocardial band and clinical events. CONCLUSION: The aim of the IMPACT trial is to evaluate the effect of melatonin on reperfusion...

  7. High Resolution Energetic X-ray Imager (HREXI)

    Science.gov (United States)

    Grindlay, Jonathan

    We propose to design and build the first imaging hard X-ray detector system that incorporates 3D stacking of closely packed detector readouts in finely-spaced imaging arrays with their required data processing and control electronics. In virtually all imaging astronomical detectors, detector readout is done with flex connectors or connections that are not vertical but rather horizontal , requiring loss of focal plane area. For high resolution pixel detectors needed for high speed event-based X-ray imaging, from low energy applications (CMOS) with focusing X-ray telescopes, to hard X-ray applications with pixelated CZT for large area coded aperture telescopes, this new detector development offers great promise. We propose to extend our previous and current APRA supported ProtoEXIST program that has developed the first large area imaging CZT detectors and demonstrated their astrophysical capabilities on two successful balloon flight to a next generation High Resolution Energetic X-ray Imager (HREXI), which would incorporate microvia technology for the first time to connect the readout ASIC on each CZT crystal directly to its control and data processing system. This 3-dimensional stacking of detector and readout/control system means that large area (>2m2) imaging detector planes for a High Resolution Wide-field hard X-ray telescope can be built with initially greatly reduced detector gaps and ultimately with no gaps. This increases detector area, efficiency, and simplicity of detector integration. Thus higher sensitivity wide-field imagers will be possible at lower cost. HREXI will enable a post-Swift NASA mission such as the EREXS concept proposed to PCOS to be conducted as a future MIDEX mission. This mission would conduct a high resolution (<2 arcmin) , broad band (5 200 keV) hard X-ray survey of black holes on all scales with ~10X higher sensitivity than Swift. In the current era of Time Domain Astrophysics, such a survey capability, in conjunction with a n

  8. Benefits of lifelong exercise training on left ventricular function after myocardial infarction.

    Science.gov (United States)

    Maessen, Martijn Fh; Eijsvogels, Thijs Mh; Stevens, Guus; van Dijk, Arie Pj; Hopman, Maria Te

    2017-11-01

    Background Endurance exercise training induces cardio-protective effects, but athletes are not exempted from a myocardial infarction. Evidence from animal studies suggests that exercise training attenuates pathological left ventricular remodelling following myocardial infarction. We tested the hypothesis that lifelong exercise training is related to attenuated pathological left ventricular remodelling after myocardial infarction as evidenced by better left ventricular systolic function in veteran athletes compared to sedentary peers. Design This was a cross-sectional study. Methods Sixty-five males (60 ± 6 years) were included and allocated to four groups based on lifelong exercise training volumes: (a) athletes ( n = 18), (b) post-myocardial infarction athletes (athletes + myocardial infarction, n = 20), (c) sedentary controls ( n = 13), and (d) post-myocardial infarction controls (sedentary controls + myocardial infarction, n = 14). Athletes were lifelong (≥20 years) highly physically active (≥30 metabolic equivalent of task (MET)-h/week), whereas sedentary controls did not meet the exercise guidelines (creatine-kinase, creatinine, aspartate transaminase and lactate dehydrogenase) following myocardial infarction and infarct location did not differ between athletes + myocardial infarction and sedentary controls + myocardial infarction. Left ventricular ejection fraction was significantly higher in athletes (61% ± 4), athletes + myocardial infarction (58% ± 4) and sedentary controls (57% ± 6) compared to sedentary controls + myocardial infarction (51% ± 7; p athletes (-19% (-21% to -17%), athletes + myocardial infarction (-16% (-20% to -12%)), and sedentary controls (-15% (-18% to -14%) compared to sedentary controls + myocardial infarction (-13% (-15% to -8%), p athletes.

  9. 45. Ezetimibe and statins yields on silent holter ambulatory myocardial ischemia

    Directory of Open Access Journals (Sweden)

    W. Kadro

    2016-07-01

    Full Text Available Further cholestrol lowering may affect silent ischemia detected on holter monitoring. Cholesterol lowering is associated with a reduction in cardiovascular morbidity and mortality. Statins are the main drugs for cholesterol lowering. Ezetimibe when added to statins gives further reduction in cholesterol but its long-term effect on cardiovascular morbidity and mortality and ischemic events is not known. This study sought to determine whether further cholesterol lowering with ezitimibe will also results in a reduction of myocardial ischemia during daily life. We enrolled 50 patients with proven stable coronary artery disease (CAD and at least one episode of ST-segment depression on ambulatory ECG monitoring. All of them were receiving optimal therapy for CAD including statin therapy for cholesterol reduction. 25 patients were randomized to continue their statin therapy (Statin only group and 25 to recieve statin plus ezitimibe 10 mg/day (ezitimibe group. Serum cholesterol and LDL cholesterol levels and ambulatory monitoring were repeated after 4–6 months of therapy. The two groups were comparable with respect to baseline characteristics, number of episodes of ST-segment depression, and baseline serum cholesterol levels. The ezitimibe group had lower mean total and LDL cholesterol levels at study end and experienced a significant reduction in the number of episodes of ST-segment depression compared with the statin only group. ST-segment depression was completely resolved in 13 of 25 patients (52% in the ezitimibe group versus 3 of 25 (12% in the statin only group. The ezitimibe group exhibited a highly significant reduction in ambulatory ischemia (P < .001. By logistic regression, treatment with ezitimibe was an independent predictor of ischemia resolution. Further cholesterol lowering with ezitimibe can result in reduction or resolution of myocardial ischemia recorded as episodes of ST-segment depression in ambulatory monitoring of the ECG.

  10. High-resolution investigations of edge effects in neutron imaging

    International Nuclear Information System (INIS)

    Strobl, M.; Kardjilov, N.; Hilger, A.; Kuehne, G.; Frei, G.; Manke, I.

    2009-01-01

    Edge enhancement is the main effect measured by the so-called inline or propagation-based neutron phase contrast imaging method. The effect has originally been explained by diffraction, and high spatial coherence has been claimed to be a necessary precondition. However, edge enhancement has also been found in conventional imaging with high resolution. In such cases the effects can produce artefacts and hinder quantification. In this letter the edge effects at cylindrical shaped samples and long straight edges have been studied in detail. The enhancement can be explained by refraction and total reflection. Using high-resolution imaging, where spatial resolutions better than 50 μm could be achieved, refraction and total reflection peaks - similar to diffraction patterns - could be separated and distinguished.

  11. High-Resolution Adaptive Optics Test-Bed for Vision Science

    International Nuclear Information System (INIS)

    Wilks, S.C.; Thomspon, C.A.; Olivier, S.S.; Bauman, B.J.; Barnes, T.; Werner, J.S.

    2001-01-01

    We discuss the design and implementation of a low-cost, high-resolution adaptive optics test-bed for vision research. It is well known that high-order aberrations in the human eye reduce optical resolution and limit visual acuity. However, the effects of aberration-free eyesight on vision are only now beginning to be studied using adaptive optics to sense and correct the aberrations in the eye. We are developing a high-resolution adaptive optics system for this purpose using a Hamamatsu Parallel Aligned Nematic Liquid Crystal Spatial Light Modulator. Phase-wrapping is used to extend the effective stroke of the device, and the wavefront sensing and wavefront correction are done at different wavelengths. Issues associated with these techniques will be discussed

  12. Ultra-high resolution AMOLED

    Science.gov (United States)

    Wacyk, Ihor; Prache, Olivier; Ghosh, Amal

    2011-06-01

    AMOLED microdisplays continue to show improvement in resolution and optical performance, enhancing their appeal for a broad range of near-eye applications such as night vision, simulation and training, situational awareness, augmented reality, medical imaging, and mobile video entertainment and gaming. eMagin's latest development of an HDTV+ resolution technology integrates an OLED pixel of 3.2 × 9.6 microns in size on a 0.18 micron CMOS backplane to deliver significant new functionality as well as the capability to implement a 1920×1200 microdisplay in a 0.86" diagonal area. In addition to the conventional matrix addressing circuitry, the HDTV+ display includes a very lowpower, low-voltage-differential-signaling (LVDS) serialized interface to minimize cable and connector size as well as electromagnetic emissions (EMI), an on-chip set of look-up-tables for digital gamma correction, and a novel pulsewidth- modulation (PWM) scheme that together with the standard analog control provides a total dimming range of 0.05cd/m2 to 2000cd/m2 in the monochrome version. The PWM function also enables an impulse drive mode of operation that significantly reduces motion artifacts in high speed scene changes. An internal 10-bit DAC ensures that a full 256 gamma-corrected gray levels are available across the entire dimming range, resulting in a measured dynamic range exceeding 20-bits. This device has been successfully tested for operation at frame rates ranging from 30Hz up to 85Hz. This paper describes the operational features and detailed optical and electrical test results for the new AMOLED WUXGA resolution microdisplay.

  13. Generalized Nonlinear Chirp Scaling Algorithm for High-Resolution Highly Squint SAR Imaging.

    Science.gov (United States)

    Yi, Tianzhu; He, Zhihua; He, Feng; Dong, Zhen; Wu, Manqing

    2017-11-07

    This paper presents a modified approach for high-resolution, highly squint synthetic aperture radar (SAR) data processing. Several nonlinear chirp scaling (NLCS) algorithms have been proposed to solve the azimuth variance of the frequency modulation rates that are caused by the linear range walk correction (LRWC). However, the azimuth depth of focusing (ADOF) is not handled well by these algorithms. The generalized nonlinear chirp scaling (GNLCS) algorithm that is proposed in this paper uses the method of series reverse (MSR) to improve the ADOF and focusing precision. It also introduces a high order processing kernel to avoid the range block processing. Simulation results show that the GNLCS algorithm can enlarge the ADOF and focusing precision for high-resolution highly squint SAR data.

  14. Generalized Nonlinear Chirp Scaling Algorithm for High-Resolution Highly Squint SAR Imaging

    Directory of Open Access Journals (Sweden)

    Tianzhu Yi

    2017-11-01

    Full Text Available This paper presents a modified approach for high-resolution, highly squint synthetic aperture radar (SAR data processing. Several nonlinear chirp scaling (NLCS algorithms have been proposed to solve the azimuth variance of the frequency modulation rates that are caused by the linear range walk correction (LRWC. However, the azimuth depth of focusing (ADOF is not handled well by these algorithms. The generalized nonlinear chirp scaling (GNLCS algorithm that is proposed in this paper uses the method of series reverse (MSR to improve the ADOF and focusing precision. It also introduces a high order processing kernel to avoid the range block processing. Simulation results show that the GNLCS algorithm can enlarge the ADOF and focusing precision for high-resolution highly squint SAR data.

  15. SURGERY OF SYMPTOMATIC MYOCARDIAL BRIDGING

    Directory of Open Access Journals (Sweden)

    N. Maghamipour N. Safaei

    2007-06-01

    Full Text Available Myocardial bridging with systolic compression of the left anterior descending coronary artery (LAD may be associated with myocardial ischemia. In symptomatic myocardial bridging unresponsive to medical treatment, surgical unroofing of the left LAD can be performed. Little information is available about the long-term prognosis of patients with this coronary anomaly after the surgical unroofing, so we decided to evaluate the result of this operation. A total of 26 patients underwent surgical unroofing of myocardial bridging. Patients had a myocardial bridge of at least 3 cm in length in the middle of LAD and with more than 70% compression during systole. Unroofing was performed with cardiopulmonary bypass in 16 and with off pump technique in 10 patients. In 6 patients repeat angiographies for control of myotomy were done. In one of them a nonsignificant 20% narrowing was seen. Postoperative scintigraphic and angiographic studies demonstrated restoration of coronary flow and myocardial perfusion without residual myocardial bridges under beta-stimulation in 24 patients. Two patients had residual narrowing. With off pump technique, 1 patient had perforation of the right ventricle and 1 patient underwent reoperation because of incomplete unroofing during the first operation. None of the patients with cardiopulmonary bypass technique had residual chest pain or other complications. Surgical unroofing of myocardial bridging with the aid of cardiopulmonary bypass is a safe and easy procedure with low operative risk and with excellent functional results.

  16. Human enamel structure studied by high resolution electron microscopy

    International Nuclear Information System (INIS)

    Wen, S.L.

    1989-01-01

    Human enamel structural features are characterized by high resolution electron microscopy. The human enamel consists of polycrystals with a structure similar to Ca10(PO4)6(OH)2. This article describes the structural features of human enamel crystal at atomic and nanometer level. Besides the structural description, a great number of high resolution images are included. Research into the carious process in human enamel is very important for human beings. This article firstly describes the initiation of caries in enamel crystal at atomic and unit-cell level and secondly describes the further steps of caries with structural and chemical demineralization. The demineralization in fact, is the origin of caries in human enamel. The remineralization of carious areas in human enamel has drawn more and more attention as its potential application is realized. This process has been revealed by high resolution electron microscopy in detail in this article. On the other hand, the radiation effects on the structure of human enamel are also characterized by high resolution electron microscopy. In order to reveal this phenomenon clearly, a great number of electron micrographs have been shown, and a physical mechanism is proposed. 26 references

  17. Refinement procedure for the image alignment in high-resolution electron tomography

    International Nuclear Information System (INIS)

    Houben, L.; Bar Sadan, M.

    2011-01-01

    High-resolution electron tomography from a tilt series of transmission electron microscopy images requires an accurate image alignment procedure in order to maximise the resolution of the tomogram. This is the case in particular for ultra-high resolution where even very small misalignments between individual images can dramatically reduce the fidelity of the resultant reconstruction. A tomographic-reconstruction based and marker-free method is proposed, which uses an iterative optimisation of the tomogram resolution. The method utilises a search algorithm that maximises the contrast in tomogram sub-volumes. Unlike conventional cross-correlation analysis it provides the required correlation over a large tilt angle separation and guarantees a consistent alignment of images for the full range of object tilt angles. An assessment based on experimental reconstructions shows that the marker-free procedure is competitive to the reference of marker-based procedures at lower resolution and yields sub-pixel accuracy even for simulated high-resolution data. -- Highlights: → Alignment procedure for electron tomography based on iterative tomogram contrast optimisation. → Marker-free, independent of object, little user interaction. → Accuracy competitive with fiducial marker methods and suited for high-resolution tomography.

  18. Myocardial perfusion imaging for detection of silent myocardial ischemia

    International Nuclear Information System (INIS)

    Beller, G.A.

    1988-01-01

    Despite the widespread use of the exercise stress test in diagnosing asymptomatic myocardial ischemia, exercise radionuclide imaging remains useful for detecting silent ischemia in numerous patient populations, including those who are totally asymptomatic, those who have chronic stable angina, those who have recovered from an episode of unstable angina or an uncomplicated myocardial infarction, and those who have undergone angioplasty or received thrombolytic therapy. Studies show that thallium scintigraphy is more sensitive than exercise electrocardiography in detecting ischemia, i.e., in part, because perfusion defects occur more frequently than ST depression and before angina in the ischemic cascade. Thallium-201 scintigraphy can be performed to differentiate a true- from a false-positive exercise electrocardiographic test in patients with exercise-induced ST depression and no angina. The development of technetium-labeled isonitriles may improve the accuracy of myocardial perfusion imaging. 11 references

  19. High resolution backscattering instruments

    International Nuclear Information System (INIS)

    Coldea, R.

    2001-01-01

    The principle of operation of indirect-geometry time-of-flight spectrometers are presented, including the IRIS at the ISIS spallation neutron source. The key features that make those types of spectrometers ideally suited for low-energy spectroscopy are: high energy resolution over a wide dynamic range, and simultaneous measurement over a large momentum transfer range provided by the wide angular detector coverage. To exemplify these features are discussed of single-crystal experiments of the spin dynamics in the two-dimensional frustrated quantum magnet Cs 2 CuCl 4 . (R.P.)

  20. Application of myocardial perfusion quantitative imaging for the evaluation of therapeutic effect in canine with myocardial infarction

    International Nuclear Information System (INIS)

    Liang Hong; Chen Ju; Liu Sheng; Zeng Shiquan

    2000-01-01

    Myocardial blood perfusion (MBP) ECT and quantitative analysis were performed in 10 canines with experimental acute myocardial infarct (AMI). The accuracy of main myocardial quantitative index, including defect volume (DV) and defect fraction (DF), was estimated and correlated with histochemical staining (HS) of infarcted area. Other 21/AMI canines were divided into Nd:YAG laser trans-myocardial revascularization treated group LTMR and control group. All canines were performed MBP ECT after experimental AMI. Results found that the infarcted volume (IV) measured by HS has well correlated (r 0.88) with DV estimated by myocardial quantitative analysis. But the DF values calculated by both methods was not significantly different (t = 1.28 P > 0.05). In LTMR group 27.5% +- 3.9%, the DF is smaller than control group 32.1% +- 4.6% (t = 2.49 P 99m Tc-MIBI myocardial perfusion SPECT and quantitative study can accurately predict the myocardial blood flow and magnitude of injured myocardium. Nd:YAG LTMR could improve myocardial blood perfusion of ischemic myocardium and decrease effectively the infarct areas

  1. Using Adobe Acrobat to create high-resolution line art images.

    Science.gov (United States)

    Woo, Hyoun Sik; Lee, Jeong Min

    2009-08-01

    The purpose of this article is to introduce a method for using Adobe Acrobat to make high-resolution and high-quality line art images. High-resolution and high-quality line art images for radiology journal submission can be generated using Adobe Acrobat as a steppingstone, and the customized PDF conversion settings can be used for converting hybrid images, including both bitmap and vector components.

  2. High-resolution axial MR imaging of tibial stress injuries

    Directory of Open Access Journals (Sweden)

    Mammoto Takeo

    2012-05-01

    Full Text Available Abstract Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries.

  3. High-resolution axial MR imaging of tibial stress injuries

    Science.gov (United States)

    2012-01-01

    Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries. PMID:22574840

  4. High-resolution esophageal pressure topography for esophageal motility disorders

    OpenAIRE

    Hashem Fakhre Yaseri; Gholamreza Hamsi; Tayeb Ramim

    2016-01-01

    Background: High-resolution manometer (HRM) of the esophagus has become the main diagnostic test in the evaluation of esophageal motility disorders. The development of high-resolution manometry catheters and software displays of manometry recordings in color-coded pressure plots have changed the diagnostic assessment of esophageal disease. The first step of the Chicago classification described abnormal esophagogastric junction deglutitive relaxation. The latest classification system, proposed...

  5. Quantitation of Acrylamide in Foods by High-Resolution Mass Spectrometry

    NARCIS (Netherlands)

    Troise, A.D.; Fogliano, Vincenzo

    2016-01-01

    The use of liquid chromatography high-resolution mass spectrometry (LC-HRMS) and direct analysis real-time high-resolution mass spectrometry (DART-HRMS) defines a new scenario in the analysis of thermal-induced toxicants, such as acrylamide. Several factors contribute to the definition of the

  6. High-spin research with HERA [High Energy-Resolution Array

    International Nuclear Information System (INIS)

    Diamond, R.M.

    1987-06-01

    The topic of this report is high spin research with the High Energy Resolution Array (HERA) at Lawrence Berkeley Laboratory. This is a 21 Ge detector system, the first with bismuth germanate (BGO) Compton suppression. The array is described briefly and some of the results obtained during the past year using this detector facility are discussed. Two types of studies are described: observation of superdeformation in the light Nd isotopes, and rotational damping at high spin and excitation energy in the continuum gamma ray spectrum

  7. Ultra high resolution soft x-ray tomography

    International Nuclear Information System (INIS)

    Haddad, W.S.; Trebes, J.E.; Goodman, D.M.

    1995-01-01

    Ultra high resolution three dimensional images of a microscopic test object were made with soft x-rays using a scanning transmission x-ray microscope. The test object consisted of two different patterns of gold bars on silicon nitride windows that were separated by ∼5μm. A series of nine 2-D images of the object were recorded at angles between -50 to +55 degrees with respect to the beam axis. The projections were then combined tomographically to form a 3-D image by means of an algebraic reconstruction technique (ART) algorithm. A transverse resolution of ∼1000 Angstrom was observed. Artifacts in the reconstruction limited the overall depth resolution to ∼6000 Angstrom, however some features were clearly reconstructed with a depth resolution of ∼1000 Angstrom. A specially modified ART algorithm and a constrained conjugate gradient (CCG) code were also developed as improvements over the standard ART algorithm. Both of these methods made significant improvements in the overall depth resolution bringing it down to ∼1200 Angstrom overall. Preliminary projection data sets were also recorded with both dry and re-hydrated human sperm cells over a similar angular range

  8. Ultra high resolution soft x-ray tomography

    International Nuclear Information System (INIS)

    Haddad, W.S.; Trebes, J.E.; Goodman, D.M.; Lee, H.R.; McNulty, I.; Zalensky, A.O.

    1995-01-01

    Ultra high resolution three dimensional images of a microscopic test object were made with soft x-rays using a scanning transmission x-ray microscope. The test object consisted of two different patterns of gold bars on silicon nitride windows that were separated by ∼5 microm. A series of nine 2-D images of the object were recorded at angles between -50 to +55 degrees with respect to the beam axis. The projections were then combined tomographically to form a 3-D image by means of an algebraic reconstruction technique (ART) algorithm. A transverse resolution of ∼ 1,000 angstrom was observed. Artifacts in the reconstruction limited the overall depth resolution to ∼ 6,000 angstrom, however some features were clearly reconstructed with a depth resolution of ∼ 1,000 angstrom. A specially modified ART algorithm and a constrained conjugate gradient (CCG) code were also developed as improvements over the standard ART algorithm. Both of these methods made significant improvements in the overall depth resolution, bringing it down to ∼ 1,200 angstrom overall. Preliminary projection data sets were also recorded with both dry and re-hydrated human sperm cells over a similar angular range

  9. Quantitative Myocardial Perfusion with Dynamic Contrast-Enhanced Imaging in MRI and CT: Theoretical Models and Current Implementation

    Directory of Open Access Journals (Sweden)

    G. J. Pelgrim

    2016-01-01

    Full Text Available Technological advances in magnetic resonance imaging (MRI and computed tomography (CT, including higher spatial and temporal resolution, have made the prospect of performing absolute myocardial perfusion quantification possible, previously only achievable with positron emission tomography (PET. This could facilitate integration of myocardial perfusion biomarkers into the current workup for coronary artery disease (CAD, as MRI and CT systems are more widely available than PET scanners. Cardiac PET scanning remains expensive and is restricted by the requirement of a nearby cyclotron. Clinical evidence is needed to demonstrate that MRI and CT have similar accuracy for myocardial perfusion quantification as PET. However, lack of standardization of acquisition protocols and tracer kinetic model selection complicates comparison between different studies and modalities. The aim of this overview is to provide insight into the different tracer kinetic models for quantitative myocardial perfusion analysis and to address typical implementation issues in MRI and CT. We compare different models based on their theoretical derivations and present the respective consequences for MRI and CT acquisition parameters, highlighting the interplay between tracer kinetic modeling and acquisition settings.

  10. High-resolution 3D imaging of polymerized photonic crystals by lab-based x-ray nanotomography with 50-nm resolution

    Science.gov (United States)

    Yin, Leilei; Chen, Ying-Chieh; Gelb, Jeff; Stevenson, Darren M.; Braun, Paul A.

    2010-09-01

    High resolution x-ray computed tomography is a powerful non-destructive 3-D imaging method. It can offer superior resolution on objects that are opaque or low contrast for optical microscopy. Synchrotron based x-ray computed tomography systems have been available for scientific research, but remain difficult to access for broader users. This work introduces a lab-based high-resolution x-ray nanotomography system with 50nm resolution in absorption and Zernike phase contrast modes. Using this system, we have demonstrated high quality 3-D images of polymerized photonic crystals which have been analyzed for band gap structures. The isotropic volumetric data shows excellent consistency with other characterization results.

  11. High-resolution nuclear magnetic resonance studies of proteins.

    Science.gov (United States)

    Jonas, Jiri

    2002-03-25

    The combination of advanced high-resolution nuclear magnetic resonance (NMR) techniques with high-pressure capability represents a powerful experimental tool in studies of protein folding. This review is organized as follows: after a general introduction of high-pressure, high-resolution NMR spectroscopy of proteins, the experimental part deals with instrumentation. The main section of the review is devoted to NMR studies of reversible pressure unfolding of proteins with special emphasis on pressure-assisted cold denaturation and the detection of folding intermediates. Recent studies investigating local perturbations in proteins and the experiments following the effects of point mutations on pressure stability of proteins are also discussed. Ribonuclease A, lysozyme, ubiquitin, apomyoglobin, alpha-lactalbumin and troponin C were the model proteins investigated.

  12. High-resolution CT of the lungs: Anatomic-pathologic correlation

    International Nuclear Information System (INIS)

    Stein, M.G.; Webb, W.R.; Finkbeiner, W.; Gamsu, G.

    1986-01-01

    The interpretation of thin-section (1.5-mm), high-resolution CT scans of the lungs has been limited by lack of direct radiologic and pathologic correlation. The author scanned fresh inflated isolated lungs from ten healthy and five diseased subjects using thin-section, high-resolution techniques. The lungs were then fixed by inflation with endobronchial Formalin. Gough sections (1 mm thick) were obtained at the same levels as the CT scans. In healthy subjects, secondary lobules were identified by the presence of visible interlobular septa and central arterioles. In some patients with disease, septal thickening was visible. In patients with honeycombing cystic areas of destroyed lung were seen, along with areas of fibrosis. Emphysema was well evaluated. Thin-section, high-resolution CT can define lung architecture and may resolve mild changes of the interstitium

  13. High-resolution x-ray imaging using a structured scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Hormozan, Yashar, E-mail: hormozan@kth.se; Sychugov, Ilya; Linnros, Jan [Materials and Nano Physics, School of Information and Communication Technology, KTH Royal Institute of Technology, Electrum 229, Kista, Stockholm SE-16440 (Sweden)

    2016-02-15

    Purpose: In this study, the authors introduce a new generation of finely structured scintillators with a very high spatial resolution (a few micrometers) compared to conventional scintillators, yet maintaining a thick absorbing layer for improved detectivity. Methods: Their concept is based on a 2D array of high aspect ratio pores which are fabricated by ICP etching, with spacings (pitches) of a few micrometers, on silicon and oxidation of the pore walls. The pores were subsequently filled by melting of powdered CsI(Tl), as the scintillating agent. In order to couple the secondary emitted photons of the back of the scintillator array to a CCD device, having a larger pixel size than the pore pitch, an open optical microscope with adjustable magnification was designed and implemented. By imaging a sharp edge, the authors were able to calculate the modulation transfer function (MTF) of this finely structured scintillator. Results: The x-ray images of individually resolved pores suggest that they have been almost uniformly filled, and the MTF measurements show the feasibility of a few microns spatial resolution imaging, as set by the scintillator pore size. Compared to existing techniques utilizing CsI needles as a structured scintillator, their results imply an almost sevenfold improvement in resolution. Finally, high resolution images, taken by their detector, are presented. Conclusions: The presented work successfully shows the functionality of their detector concept for high resolution imaging and further fabrication developments are most likely to result in higher quantum efficiencies.

  14. Science with High Spatial Resolution Far-Infrared Data

    Science.gov (United States)

    Terebey, Susan (Editor); Mazzarella, Joseph M. (Editor)

    1994-01-01

    The goal of this workshop was to discuss new science and techniques relevant to high spatial resolution processing of far-infrared data, with particular focus on high resolution processing of IRAS data. Users of the maximum correlation method, maximum entropy, and other resolution enhancement algorithms applicable to far-infrared data gathered at the Infrared Processing and Analysis Center (IPAC) for two days in June 1993 to compare techniques and discuss new results. During a special session on the third day, interested astronomers were introduced to IRAS HIRES processing, which is IPAC's implementation of the maximum correlation method to the IRAS data. Topics discussed during the workshop included: (1) image reconstruction; (2) random noise; (3) imagery; (4) interacting galaxies; (5) spiral galaxies; (6) galactic dust and elliptical galaxies; (7) star formation in Seyfert galaxies; (8) wavelet analysis; and (9) supernova remnants.

  15. Textural Segmentation of High-Resolution Sidescan Sonar Images

    National Research Council Canada - National Science Library

    Kalcic, Maria; Bibee, Dale

    1995-01-01

    .... The high resolution of the 455 kHz sonar imagery also provides much information about the surficial bottom sediments, however their acoustic scattering properties are not well understood at high frequencies...

  16. High-resolution computed tomography findings in pulmonary Langerhans cell histiocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Rosana Souza [Universidade Federal do Rio de Janeiro (HUCFF/UFRJ), RJ (Brazil). Hospital Universitario Clementino Fraga Filho. Unit of Radiology; Capone, Domenico; Ferreira Neto, Armando Leao [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil)

    2011-07-15

    Objective: The present study was aimed at characterizing main lung changes observed in pulmonary Langerhans cell histiocytosis by means of high-resolution computed tomography. Materials and Methods: High-resolution computed tomography findings in eight patients with proven disease diagnosed by open lung biopsy, immunohistochemistry studies and/or extrapulmonary manifestations were retrospectively evaluated. Results: Small rounded, thin-walled cystic lesions were observed in the lung of all the patients. Nodules with predominantly peripheral distribution over the lung parenchyma were observed in 75% of the patients. The lesions were diffusely distributed, predominantly in the upper and middle lung fields in all of the cases, but involvement of costophrenic angles was observed in 25% of the patients. Conclusion: Comparative analysis of high-resolution computed tomography and chest radiography findings demonstrated that thinwalled cysts and small nodules cannot be satisfactorily evaluated by conventional radiography. Because of its capacity to detect and characterize lung cysts and nodules, high-resolution computed tomography increases the probability of diagnosing pulmonary Langerhans cell histiocytosis. (author)

  17. Normal 201Tl SPECT myocardial scintigram - a basis for quantification of tomographic data using 1800 rotation

    International Nuclear Information System (INIS)

    Bock, A.; Frenzel, R.; Meyer, M.; Pink, V.; Reisinger, I.; Strangfeld, D.

    1990-01-01

    Using 180 0 rotation for 201 Tl myocardial perfusion SPECT the influence of different myocardial wall thickness, depth-dependent resolution, attenuation and other facts is the reason for about 30% inhomogenity from anterolateral to posteroseptal myocardium in polar coordinate Bull's eye. It is very difficult for a visual observer to assess patients without knowledge of the corresponding normal distribution. We studied 25 normal males and calculated pixelwice vitality, washout rate between stress, 2-hr and 3.5-hr delay to obtain a normal Bull's eye reference databank. Before the patient's data can be analysed it is necessary to multiplicate them with the inverse normal Bull's eye. (author)

  18. Exercise and rest Tl-201 myocardial SPECT, and low dose dobutamine echocardiography to assess myocardial viability in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Toyama, Takuji; Ishida, Yoshio; Shimonagata, Tsuyoshi; Kawano, Shigeo; Beppu, Shintaro; Nishimura, Tsunehiko.

    1994-01-01

    To evaluate viability of infarcted myocardium, findings of Tl-201 myocardial SPECT were compared with those of low-dose dobutamine (DOB) echocardiography. The subjects were 19 patients with myocardial infarction (23 infarcted zones), consisting of 16 men and 3 women. Findings on myocardial SPECT were classified as evidence of myocardial viability (14 zones, Group A) and no evidence of myocardial viability (9 zones, Group B). For both groups, wall motion and regional % uptake (%UP) were obtained. DOB echocardiography revealed an improvement in 5 of 8 akinesis zones in Group A. In addition, one other zone was found improved by follow-up examination. Six hypokinesis zones were all found improved on DOB echocardiography. Out of a total of 14 akinesis or hypokinesis zones, 11 (79%) showed improvement on DOB echocardiography in Group A. In Group B, all akinesis zones remained unchanged on DOB echocardiography, although one zone was improved by follow-up examination. In 11 zones in which wall motion was improved on DOB echocardiography, %UT was increased by an average of 58% on 4 hr-delayed images and 70% on resting images. The corresponding figures for 12 zones which did not improve on DOB echocardiography were 49% and 50% on the average, respectively. In conclusion, low-dose DOB echocardiography appeared to reflect viability of severely infarcted myocardium, although it had a slightly lower sensitivity than convensional Tl-201 myocardial SPECT in its ability to detect. (N.K.)

  19. Myocardial contusion following nonfatal blunt chest trauma

    International Nuclear Information System (INIS)

    Kumar, S.A.; Puri, V.K.; Mittal, V.K.; Cortez, J.

    1983-01-01

    Currently available diagnostic techniques for myocardial contusion following blunt chest trauma were evaluated. We investigated 30 patients prospectively over a period of 1 year for the presence of myocardial contusion. Among the 30 patients, eight were found to have myocardial contusion on the basis of abnormal electrocardiograms, elevated creatine phosphokinase MB fraction (CPK-MB), and positive myocardial scan. Myocardial scan was positive in seven of eight patients (87.5%). CPK-MB fraction was elevated in four of eight patients (50%). Definitive electrocardiographic changes were seen in only two of eight patients (25%). It appears that myocardial scan using technetium pyrophosphate and CPK-MB fraction determinations are the most reliable aids in diagnosis of myocardial contusion following blunt chest trauma

  20. A Forward-Looking High-Resolution GPR System

    National Research Council Canada - National Science Library

    Kositsky, Joel; Milanfar, Peyman

    1999-01-01

    A high-resolution ground penetrating radar (GPR) system was designed to help define the optimal radar parameters needed for the efficient standoff detection of buried and surface-laid antitank mines...

  1. Accelerated high-resolution photoacoustic tomography via compressed sensing

    Science.gov (United States)

    Arridge, Simon; Beard, Paul; Betcke, Marta; Cox, Ben; Huynh, Nam; Lucka, Felix; Ogunlade, Olumide; Zhang, Edward

    2016-12-01

    Current 3D photoacoustic tomography (PAT) systems offer either high image quality or high frame rates but are not able to deliver high spatial and temporal resolution simultaneously, which limits their ability to image dynamic processes in living tissue (4D PAT). A particular example is the planar Fabry-Pérot (FP) photoacoustic scanner, which yields high-resolution 3D images but takes several minutes to sequentially map the incident photoacoustic field on the 2D sensor plane, point-by-point. However, as the spatio-temporal complexity of many absorbing tissue structures is rather low, the data recorded in such a conventional, regularly sampled fashion is often highly redundant. We demonstrate that combining model-based, variational image reconstruction methods using spatial sparsity constraints with the development of novel PAT acquisition systems capable of sub-sampling the acoustic wave field can dramatically increase the acquisition speed while maintaining a good spatial resolution: first, we describe and model two general spatial sub-sampling schemes. Then, we discuss how to implement them using the FP interferometer and demonstrate the potential of these novel compressed sensing PAT devices through simulated data from a realistic numerical phantom and through measured data from a dynamic experimental phantom as well as from in vivo experiments. Our results show that images with good spatial resolution and contrast can be obtained from highly sub-sampled PAT data if variational image reconstruction techniques that describe the tissues structures with suitable sparsity-constraints are used. In particular, we examine the use of total variation (TV) regularization enhanced by Bregman iterations. These novel reconstruction strategies offer new opportunities to dramatically increase the acquisition speed of photoacoustic scanners that employ point-by-point sequential scanning as well as reducing the channel count of parallelized schemes that use detector arrays.

  2. Diagnosis of coronary stenosis using thallium-201 myocardial emission computed tomography

    International Nuclear Information System (INIS)

    Ito, Tsunaaki; Takeda, Hiroshi; Maeda, Hisato; Nakagawa, Tsuyoshi; Yamaguchi, Nobuo; Makino, Katsutoshi; Futagami, Yasuo; Konishi, Tokuji

    1985-01-01

    Thallium-201 myocardial emission computed tomography (ECT) was described with respect to methods of correcting ECT data and reconstructing the images, qualitative and quantitative diagnosis in the detection of coronary stenosis. Although 201 Tl myocardial ECT (using circumferential profile method combined with washout method) has relatively high diagnostic sensitivity, the correction of absorption is not satisfactory yet. Inside absorption coefficient is considered uniform by regarding the human body as oval shape. However, the chest, including the heart, lungs, vertebrae and thoracic wall, has four different absorption coefficients. If absorption can be corrected accurately, it will be possible to completely assess the myocardial blood flow by measuring the regional myocardial uptake of thallium-201. (Namekawa, K.)

  3. A Very High Spatial Resolution Detector for Small Animal PET

    International Nuclear Information System (INIS)

    Kanai Shah, M.S.

    2007-01-01

    Positron Emission Tomography (PET) is an in vivo analog of autoradiography and has the potential to become a powerful new tool in imaging biological processes in small laboratory animals. PET imaging of small animals can provide unique information that can help in advancement of human disease models as well as drug development. Clinical PET scanners used for human imaging are bulky, expensive and do not have adequate spatial resolution for small animal studies. Hence, dedicated, low cost instruments are required for conducting small animal studies with higher spatial resolution than what is currently achieved with clinical as well as dedicated small animal PET scanners. The goal of the proposed project is to investigate a new all solid-state detector design for small animal PET imaging. Exceptionally high spatial resolution, good timing resolution, and excellent energy resolution are expected from the proposed detector design. The Phase I project was aimed at demonstrating the feasibility of producing high performance solid-state detectors that provide high sensitivity, spatial resolution, and timing characteristics. Energy resolution characteristics of the new detector were also investigated. The goal of the Phase II project is to advance the promising solid-state detector technology for small animal PET and determine its full potential. Detectors modules will be built and characterized and finally, a bench-top small animal PET system will be assembled and evaluated

  4. Scintigraphic demonstration of acute myocardial infarcts

    International Nuclear Information System (INIS)

    Holman, B.L.; Lesch, M.

    1976-01-01

    The feasibility of acute infarct scintigraphy for the clinical evaluation of patients with known or suspected acute myocardial infarction is established. Further development of this methodologic approach may result in even better agents for the visualization of infarcts. Radiotracers with high affinity for the infarct, rapid blood clearance, and low concentrations in surrounding organs, such as liver and bone, would be more suitable than available radiopharmaceuticals for acute myocardial infarct scintigraphy. Ultimately, labeling these tracers and ultra-short-lived radionuclides will enable rapid sequential imaging to assess changes in the extent of infarction and to determine the efficacy of therapies aimed at limiting infarct size

  5. Strengthening IAEA safeguards using high-resolution commercial satellite imagery

    International Nuclear Information System (INIS)

    Zhang Hui

    2001-01-01

    Full text: In May 1997, the IAEA Board of Governors adopted the Additional Safeguards Protocol to improve its ability to detect the undeclared production of fissile material. This new strengthened safeguards system has opened the door for the IAEA to use of all types of information, including the potential use of commercial satellite imagery. We have therefore been investigating the feasibility of strengthening IAEA safeguards using commercial satellite imagery. Based on our analysis on a number of one-meter resolution IKONOS satellite images of military nuclear production facilities at nuclear states including Russia, China, India, Pakistan and Israel, we found that the new high-resolution commercial satellite imagery would play a new and valuable role in strengthening IAEA safeguards. Since 1999, images with a resolution of one meter have been available commercially from Space Imaging's IKONOS satellite. One-meter images from other companies are expected to enter the market soon. Although still an order of magnitude less capable than military imaging satellites, the capabilities of these new high-resolution commercial satellites are good enough to detect and identify the major visible characteristics of nuclear production facilities and sites. Unlike the classified spy satellite photos limited to few countries, the commercial satellite imagery is commercially available to anyone who wants to purchase it. Therefore, the new commercial satellite open a new chance that each state, international organizations, and non-governmental groups could use the commercial images to play a more proactive role in monitoring the nuclear activities in related countries and verifying the compliance of non-proliferation agreements. This could help galvanize support for intensified efforts to slow the pace of nuclear proliferation. To produce fissile materials (plutonium and highly enriched uranium) for weapons, a country would operate dedicated plutonium-production reactors and the

  6. Processing method for high resolution monochromator

    International Nuclear Information System (INIS)

    Kiriyama, Koji; Mitsui, Takaya

    2006-12-01

    A processing method for high resolution monochromator (HRM) has been developed at Japanese Atomic Energy Agency/Quantum Beam Science Directorate/Synchrotron Radiation Research unit at SPring-8. For manufacturing a HRM, a sophisticated slicing machine and X-ray diffractometer have been installed for shaping a crystal ingot and orienting precisely the surface of a crystal ingot, respectively. The specification of the slicing machine is following; Maximum size of a diamond blade is φ 350mm in diameter, φ 38.1mm in the spindle diameter, and 2mm in thickness. A large crystal such as an ingot with 100mm in diameter, 200mm in length can be cut. Thin crystal samples such as a wafer can be also cut using by another sample holder. Working distance of a main shaft with the direction perpendicular to working table in the machine is 350mm at maximum. Smallest resolution of the main shaft with directions of front-and-back and top-and-bottom are 0.001mm read by a digital encoder. 2mm/min can set for cutting samples in the forward direction. For orienting crystal faces relative to the blade direction adjustment, a one-circle goniometer and 2-circle segment are equipped on the working table in the machine. A rotation and a tilt of the stage can be done by manual operation. Digital encoder in a turn stage is furnished and has angle resolution of less than 0.01 degrees. In addition, a hand drill as a supporting device for detailed processing of crystal is prepared. Then, an ideal crystal face can be cut from crystal samples within an accuracy of about 0.01 degrees. By installation of these devices, a high energy resolution monochromator crystal for inelastic x-ray scattering and a beam collimator are got in hand and are expected to be used for nanotechnology studies. (author)

  7. High-resolution coded-aperture design for compressive X-ray tomography using low resolution detectors

    Science.gov (United States)

    Mojica, Edson; Pertuz, Said; Arguello, Henry

    2017-12-01

    One of the main challenges in Computed Tomography (CT) is obtaining accurate reconstructions of the imaged object while keeping a low radiation dose in the acquisition process. In order to solve this problem, several researchers have proposed the use of compressed sensing for reducing the amount of measurements required to perform CT. This paper tackles the problem of designing high-resolution coded apertures for compressed sensing computed tomography. In contrast to previous approaches, we aim at designing apertures to be used with low-resolution detectors in order to achieve super-resolution. The proposed method iteratively improves random coded apertures using a gradient descent algorithm subject to constraints in the coherence and homogeneity of the compressive sensing matrix induced by the coded aperture. Experiments with different test sets show consistent results for different transmittances, number of shots and super-resolution factors.

  8. Hypertension impairs myocardial blood perfusion reserve in subjects without regional myocardial ischemia

    International Nuclear Information System (INIS)

    Nakajima, Hiroshi; Onishi, Katsuya; Kurita, Tairo

    2010-01-01

    Quantitative analysis of myocardial perfusion MRI can provide noninvasive assessments of myocardial perfusion reserve (MPR), which is associated with endothelial function. Endothelial function is influenced by various factors, including hypertension, diabetes, dyslipidemia, renal dysfunction and anemia. The purpose of this study was to evaluate which risk factor is the strongest effector of MPR in subjects without regional myocardial ischemia. We studied 110 patients (66 years ±10, male 68%, hypertension 76%, diabetes mellitus (DM) 40% and dyslipidemia 65%) without regional myocardial ischemia. Adenosine triphosphate (ATP) stress and rest first-pass perfusion magnetic resonance (MR) images were acquired with a 1.5-T MR system, and MPR was calculated as the ratio of stress to rest myocardial blood flow (MBF). Average rest MBF in 110 patients was 1.07±0.62 ml min -1 g -1 , whereas stress MBF was 3.15±1.93 ml min -1 g -1 and the MPR was 3.33±1.82. Rest MBF correlated significantly with hematocrit, whereas stress MBF showed a strong correlation with estimated glomerular filtration rate (e-GFR). MPR was associated with hypertension, age, e-GFR, hematocrit and left ventricular mass index (LVMI). In multiple regression analysis, hypertension (P=0.003, β=-0.274) showed the strongest correlation with MPR among other risk factors, such as diabetes (P=ns), dyslipidemia (P=ns), e-GFR (P=ns), LVMI (P=0.007, β=-0.248) and hematocrit (P=ns) after adjusting age and gender. Hypertension is the most important effector of MPR in subjects without myocardial ischemia. (author)

  9. Hypertension impairs myocardial blood perfusion reserve in subjects without regional myocardial ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Hiroshi; Onishi, Katsuya; Kurita, Tairo [Mie Univ., Graduate School of Medicine, Tsu, Mie (Japan)

    2010-11-15

    Quantitative analysis of myocardial perfusion MRI can provide noninvasive assessments of myocardial perfusion reserve (MPR), which is associated with endothelial function. Endothelial function is influenced by various factors, including hypertension, diabetes, dyslipidemia, renal dysfunction and anemia. The purpose of this study was to evaluate which risk factor is the strongest effector of MPR in subjects without regional myocardial ischemia. We studied 110 patients (66 years {+-}10, male 68%, hypertension 76%, diabetes mellitus (DM) 40% and dyslipidemia 65%) without regional myocardial ischemia. Adenosine triphosphate (ATP) stress and rest first-pass perfusion magnetic resonance (MR) images were acquired with a 1.5-T MR system, and MPR was calculated as the ratio of stress to rest myocardial blood flow (MBF). Average rest MBF in 110 patients was 1.07{+-}0.62 ml min{sup -1} g{sup -1}, whereas stress MBF was 3.15{+-}1.93 ml min{sup -1} g{sup -1} and the MPR was 3.33{+-}1.82. Rest MBF correlated significantly with hematocrit, whereas stress MBF showed a strong correlation with estimated glomerular filtration rate (e-GFR). MPR was associated with hypertension, age, e-GFR, hematocrit and left ventricular mass index (LVMI). In multiple regression analysis, hypertension (P=0.003, {beta}=-0.274) showed the strongest correlation with MPR among other risk factors, such as diabetes (P=ns), dyslipidemia (P=ns), e-GFR (P=ns), LVMI (P=0.007, {beta}=-0.248) and hematocrit (P=ns) after adjusting age and gender. Hypertension is the most important effector of MPR in subjects without myocardial ischemia. (author)

  10. Low dose dynamic CT myocardial perfusion imaging using a statistical iterative reconstruction method

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Yinghua [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States); Chen, Guang-Hong [Department of Medical Physics and Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States); Hacker, Timothy A.; Raval, Amish N. [Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Van Lysel, Michael S.; Speidel, Michael A., E-mail: speidel@wisc.edu [Department of Medical Physics and Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States)

    2014-07-15

    Purpose: Dynamic CT myocardial perfusion imaging has the potential to provide both functional and anatomical information regarding coronary artery stenosis. However, radiation dose can be potentially high due to repeated scanning of the same region. The purpose of this study is to investigate the use of statistical iterative reconstruction to improve parametric maps of myocardial perfusion derived from a low tube current dynamic CT acquisition. Methods: Four pigs underwent high (500 mA) and low (25 mA) dose dynamic CT myocardial perfusion scans with and without coronary occlusion. To delineate the affected myocardial territory, an N-13 ammonia PET perfusion scan was performed for each animal in each occlusion state. Filtered backprojection (FBP) reconstruction was first applied to all CT data sets. Then, a statistical iterative reconstruction (SIR) method was applied to data sets acquired at low dose. Image voxel noise was matched between the low dose SIR and high dose FBP reconstructions. CT perfusion maps were compared among the low dose FBP, low dose SIR and high dose FBP reconstructions. Numerical simulations of a dynamic CT scan at high and low dose (20:1 ratio) were performed to quantitatively evaluate SIR and FBP performance in terms of flow map accuracy, precision, dose efficiency, and spatial resolution. Results: Forin vivo studies, the 500 mA FBP maps gave −88.4%, −96.0%, −76.7%, and −65.8% flow change in the occluded anterior region compared to the open-coronary scans (four animals). The percent changes in the 25 mA SIR maps were in good agreement, measuring −94.7%, −81.6%, −84.0%, and −72.2%. The 25 mA FBP maps gave unreliable flow measurements due to streaks caused by photon starvation (percent changes of +137.4%, +71.0%, −11.8%, and −3.5%). Agreement between 25 mA SIR and 500 mA FBP global flow was −9.7%, 8.8%, −3.1%, and 26.4%. The average variability of flow measurements in a nonoccluded region was 16.3%, 24.1%, and 937

  11. Low dose dynamic CT myocardial perfusion imaging using a statistical iterative reconstruction method

    International Nuclear Information System (INIS)

    Tao, Yinghua; Chen, Guang-Hong; Hacker, Timothy A.; Raval, Amish N.; Van Lysel, Michael S.; Speidel, Michael A.

    2014-01-01

    Purpose: Dynamic CT myocardial perfusion imaging has the potential to provide both functional and anatomical information regarding coronary artery stenosis. However, radiation dose can be potentially high due to repeated scanning of the same region. The purpose of this study is to investigate the use of statistical iterative reconstruction to improve parametric maps of myocardial perfusion derived from a low tube current dynamic CT acquisition. Methods: Four pigs underwent high (500 mA) and low (25 mA) dose dynamic CT myocardial perfusion scans with and without coronary occlusion. To delineate the affected myocardial territory, an N-13 ammonia PET perfusion scan was performed for each animal in each occlusion state. Filtered backprojection (FBP) reconstruction was first applied to all CT data sets. Then, a statistical iterative reconstruction (SIR) method was applied to data sets acquired at low dose. Image voxel noise was matched between the low dose SIR and high dose FBP reconstructions. CT perfusion maps were compared among the low dose FBP, low dose SIR and high dose FBP reconstructions. Numerical simulations of a dynamic CT scan at high and low dose (20:1 ratio) were performed to quantitatively evaluate SIR and FBP performance in terms of flow map accuracy, precision, dose efficiency, and spatial resolution. Results: Forin vivo studies, the 500 mA FBP maps gave −88.4%, −96.0%, −76.7%, and −65.8% flow change in the occluded anterior region compared to the open-coronary scans (four animals). The percent changes in the 25 mA SIR maps were in good agreement, measuring −94.7%, −81.6%, −84.0%, and −72.2%. The 25 mA FBP maps gave unreliable flow measurements due to streaks caused by photon starvation (percent changes of +137.4%, +71.0%, −11.8%, and −3.5%). Agreement between 25 mA SIR and 500 mA FBP global flow was −9.7%, 8.8%, −3.1%, and 26.4%. The average variability of flow measurements in a nonoccluded region was 16.3%, 24.1%, and 937

  12. Refinement procedure for the image alignment in high-resolution electron tomography.

    Science.gov (United States)

    Houben, L; Bar Sadan, M

    2011-01-01

    High-resolution electron tomography from a tilt series of transmission electron microscopy images requires an accurate image alignment procedure in order to maximise the resolution of the tomogram. This is the case in particular for ultra-high resolution where even very small misalignments between individual images can dramatically reduce the fidelity of the resultant reconstruction. A tomographic-reconstruction based and marker-free method is proposed, which uses an iterative optimisation of the tomogram resolution. The method utilises a search algorithm that maximises the contrast in tomogram sub-volumes. Unlike conventional cross-correlation analysis it provides the required correlation over a large tilt angle separation and guarantees a consistent alignment of images for the full range of object tilt angles. An assessment based on experimental reconstructions shows that the marker-free procedure is competitive to the reference of marker-based procedures at lower resolution and yields sub-pixel accuracy even for simulated high-resolution data. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Towards high resolution polarisation analysis using double polarisation and ellipsoidal analysers

    CERN Document Server

    Martin-Y-Marero, D

    2002-01-01

    Classical polarisation analysis methods lack the combination of high resolution and high count rate necessary to cope with the demand of modern condensed-matter experiments. In this work, we present a method to achieve high resolution polarisation analysis based on a double polarisation system. Coupling this method with an ellipsoidal wavelength analyser, a high count rate can be achieved whilst delivering a resolution of around 10 mu eV. This method is ideally suited to pulsed sources, although it can be adapted to continuous sources as well. (orig.)

  14. Evaluation of myocardial abnormalities in collagen diseases by thallium-201 myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yamano, Shigeru; Kagoshima, Tadashi; Sugihara, Kiyotaka (Nara Medical Univ., Kashihara (Japan)) (and others)

    1993-12-01

    This study was performed to evaluate myocardial abnormalities in patients with collagen diseases by exercise and rest thallium-201 myocardial scintigrams. A total of 65 patients without ischemic ECG changes, consisting of 18 with systemic lupus erythematosus (SLE), 18 with polymyositis (PM), 8 with progressive systemic sclerosis (PSS), and 21 with Sjoegren's syndrome (SjS), was enrolled in this study. Reversible exercise-induced defects scintigraphically suggesting myocardial ischemia were noted in 8 cases of SLE, 4 cases of PM, 4 cases of PSS, and 3 cases of SjS. Nineteen patients had exercise-induced defects and underwent cardiac catheterization, 8 of whom had normal coronary angiograms. Fixed hypoperfusion areas were observed in one case of SLE, 6 cases of PM and 3 cases of SjS. Rest thallium-201 myocardial scintigram disclosed hypoperfusion areas which were not induced by exercise in 2 cases of SLE, 3 cases of PM, one case of PSS and 5 cases of SjS. Echocardiogram showed no significant differences in ejection fraction and % fractional shortening between the disease groups and healthy control group. These findings suggest that patients with collagen diseases have abnormalities of coronary circulation at the level of the intramural vasculature before cardiac function impairment, myocardial fibrosis and functional abnormalities at the cell membrane. (author).

  15. Acute myocardial infarction in a young patient

    International Nuclear Information System (INIS)

    Hameed, A.; Ata-ur-Rehman Quraishi

    2004-01-01

    Myocardial infarction (MI) is considered to be the disease of the fifth and sixth decade as seen in the West but an earlier age incidence is not infrequently encountered in the South Asian population. However, occurrence of MI in the teen-age still remains a rare happening. We are reporting a case of a teenager, who suffered a myocardial infarction with cardiogenic shock and pulmonary edema on two separate occasions with ECG and biochemical evidence of myocardial infarction. An exercise stress test done in between the two episodes was negative at a workload of 13.5 METs. A coronary angiogram done after the second event revealed normal coronary arteries and a preserved left ventricular systolic and segmental function. Except for low HDL (high density lipoprotein) and mildly raised homocysteine levels, the patient did not have other conventional or novel risk factors for coronary artery disease. (author)

  16. Ultra-high resolution HLA genotyping and allele discovery by highly multiplexed cDNA amplicon pyrosequencing

    Directory of Open Access Journals (Sweden)

    Lank Simon M

    2012-08-01

    Full Text Available Abstract Background High-resolution HLA genotyping is a critical diagnostic and research assay. Current methods rarely achieve unambiguous high-resolution typing without making population-specific frequency inferences due to a lack of locus coverage and difficulty in exon-phase matching. Achieving high-resolution typing is also becoming more challenging with traditional methods as the database of known HLA alleles increases. Results We designed a cDNA amplicon-based pyrosequencing method to capture 94% of the HLA class I open-reading-frame with only two amplicons per sample, and an analogous method for class II HLA genes, with a primary focus on sequencing the DRB loci. We present a novel Galaxy server-based analysis workflow for determining genotype. During assay validation, we performed two GS Junior sequencing runs to determine the accuracy of the HLA class I amplicons and DRB amplicon at different levels of multiplexing. When 116 amplicons were multiplexed, we unambiguously resolved 99%of class I alleles to four- or six-digit resolution, as well as 100% unambiguous DRB calls. The second experiment, with 271 multiplexed amplicons, missed some alleles, but generated high-resolution, concordant typing for 93% of class I alleles, and 96% for DRB1 alleles. In a third, preliminary experiment we attempted to sequence novel amplicons for other class II loci with mixed success. Conclusions The presented assay is higher-throughput and higher-resolution than existing HLA genotyping methods, and suitable for allele discovery or large cohort sampling. The validated class I and DRB primers successfully generated unambiguously high-resolution genotypes, while further work is needed to validate additional class II genotyping amplicons.

  17. Transistor reset preamplifier for high-rate high-resolution spectroscopy

    International Nuclear Information System (INIS)

    Landis, D.A.; Cork, C.P.; Madden, N.W.; Goulding, F.S.

    1981-10-01

    Pulsed transistor reset of high resolution charge sensitive preamplifiers used in cooled semiconductor spectrometers can sometimes have an advantage over pulsed light reset systems. Several versions of transistor reset spectrometers using both silicon and germanium detectors have been built. This paper discusses the advantages of the transistor reset system and illustrates several configurations of the packages used for the FET and reset transistor. It also describes the preamplifer circuit and shows the performance of the spectrometer at high rates

  18. Comparison of blood biochemics between acute myocardial infarction models with blood stasis and simple acute myocardial infarction models in rats

    International Nuclear Information System (INIS)

    Qu Shaochun; Yu Xiaofeng; Wang Jia; Zhou Jinying; Xie Haolin; Sui Dayun

    2010-01-01

    Objective: To construct the acute myocardial infarction models in rats with blood stasis and study the difference on blood biochemics between the acute myocardial infarction models with blood stasis and the simple acute myocardial infarction models. Methods: Wistar rats were randomly divided into control group, acute blood stasis model group, acute myocardial infarction sham operation group, acute myocardial infarction model group and of acute myocardial infarction model with blood stasis group. The acute myocardial infarction models under the status of the acute blood stasis in rats were set up. The serum malondialdehyde (MDA), nitric oxide (NO), free fatty acid (FFA), tumor necrosis factor-α (TNF-α) levels were detected, the activities of serum superoxide dismutase (SOD), glutathione peroxidase (GSH-Px) and the levels of prostacycline (PGI2), thromboxane A 2 (TXA 2 ) and endothelin (ET) in plasma were determined. Results: There were not obvious differences in MDA, SOD, GSH-Px and FFA between the acute myocardial infarction models with blood stasis in rats and the simple acute myocardial infarction models (P 2 and NO, and the increase extents of TXA 2 , ET and TNF-α in the acute myocardial infarction models in rats with blood stasis were higher than those in the simple acute myocardial infarction models (P 2 and NO, are significant when the acute myocardial infarction models in rats with blood stasis and the simple acute myocardial infarction models are compared. The results show that it is defective to evaluate pharmacodynamics of traditional Chinese drug with only simple acute myocardial infarction models. (authors)

  19. Constructing a WISE High Resolution Galaxy Atlas

    Science.gov (United States)

    Jarrett, T. H.; Masci, F.; Tsai, C. W.; Petty, S.; Cluver, M.; Assef, Roberto J.; Benford, D.; Blain, A.; Bridge, C.; Donoso, E.; hide

    2012-01-01

    After eight months of continuous observations, the Wide-field Infrared Survey Explorer (WISE) mapped the entire sky at 3.4 micron, 4.6 micron, 12 micron, and 22 micron. We have begun a dedicated WISE High Resolution Galaxy Atlas project to fully characterize large, nearby galaxies and produce a legacy image atlas and source catalog. Here we summarize the deconvolution techniques used to significantly improve the spatial resolution of WISE imaging, specifically designed to study the internal anatomy of nearby galaxies. As a case study, we present results for the galaxy NGC 1566, comparing the WISE enhanced-resolution image processing to that of Spitzer, Galaxy Evolution Explorer, and ground-based imaging. This is the first paper in a two-part series; results for a larger sample of nearby galaxies are presented in the second paper.

  20. High resolution spectroscopy in the microwave and far infrared

    Science.gov (United States)

    Pickett, Herbert M.

    1990-01-01

    High resolution rotational spectroscopy has long been central to remote sensing techniques in atmospheric sciences and astronomy. As such, laboratory measurements must supply the required data to make direct interpretation of data for instruments which sense atmospheres using rotational spectra. Spectral measurements in the microwave and far infrared regions are also very powerful tools when combined with infrared measurements for characterizing the rotational structure of vibrational spectra. In the past decade new techniques were developed which have pushed high resolution spectroscopy into the wavelength region between 25 micrometers and 2 mm. Techniques to be described include: (1) harmonic generation of microwave sources, (2) infrared laser difference frequency generation, (3) laser sideband generation, and (4) ultrahigh resolution interferometers.

  1. Quantitative myocardial blood flow with Rubidium-82 PET

    DEFF Research Database (Denmark)

    Hagemann, Christoffer E; Ghotbi, Adam A; Kjær, Andreas

    2015-01-01

    Positron emission tomography (PET) allows assessment of myocardial blood flow in absolute terms (ml/min/g). Quantification of myocardial blood flow (MBF) and myocardial flow reserve (MFR) extend the scope of conventional semi-quantitative myocardial perfusion imaging (MPI): e.g. in 1) identificat......Positron emission tomography (PET) allows assessment of myocardial blood flow in absolute terms (ml/min/g). Quantification of myocardial blood flow (MBF) and myocardial flow reserve (MFR) extend the scope of conventional semi-quantitative myocardial perfusion imaging (MPI): e.g. in 1...... global MFR and major adverse cardiovascular events (MACE), and together with new diagnostic possibilities from measuring the longitudinal myocardial perfusion gradient, cardiac (82)Rb PET faces a promising clinical future. This article reviews current evidence on quantitative (82)Rb PET's ability...

  2. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    Science.gov (United States)

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions.

  3. The value of magnetic resonance spectroscopy in diagnosing myocardial infarction

    International Nuclear Information System (INIS)

    Gao Fabao; Huang Zhilan; Fang Hong; Zhao Haitao; Suo Liping; Gao Yuangui; Mao Songshou

    1999-01-01

    Objective: To determine the amount of high-energy phosphates and internal ratios various phosphate metabolites in myocardium of normal subjects and patients with myocardial infarction using 31 P MR spectroscopy ( 31 P MRS), and to assess the clinical value of 31 P MRS in patients with myocardial infarction (MI). Method: Fifteen patients (all men, aged 31-66 years, mean 53.8 years) of MI (acute 5, chronic 10) with ejection fraction of less than 46% and 8 healthy volunteers (normal controls) were studied using a 1.5-T Siemens Magneton 63 SP MR imager. The 10-cm diameter surface coil ( 1 H and 31 P double-tuned surface coil) was employed. To minimize motion artifacts, the subjects were examined in prone position with chest wall lying just above the surface coil. 31 P MRS study was further conducted in 7 of 15 patients after PTCA and coronary thrombolytic therapy. Results: In the control group, the myocardium PCr/β-ATP and Pi/PCr ratio were 1.58 +- 0.19 and 0.36 +- 0.17, respectively, while in patients with MI, these parameters were 0.98 +- 0.31 and 1.22 +- 0.66 (P 31 P MRS in MI in Chinese population was first reported. The contents of high-energy metabolites and their ratios in myocardium in both normal control and those with MI were studied. Myocardial high energy phosphates were not depleted in human MI. 31 P MRS possesses a great potential in evaluating myocardial viability, effects of reperfusion, and the recovery of myocardial physiologic function after reestablishment of coronary blood flow

  4. High resolution and high speed positron emission tomography data acquisition

    International Nuclear Information System (INIS)

    Burgiss, S.G.; Byars, L.G.; Jones, W.F.; Casey, M.E.

    1986-01-01

    High resolution positron emission tomography (PET) requires many detectors. Thus, data collection systems for PET must have high data rates, wide data paths, and large memories to histogram the events. This design uses the VMEbus to cost effectively provide these features. It provides for several modes of operation including real time sorting, list mode data storage, and replay of stored list mode data

  5. Ultra high spatial and temporal resolution breast imaging at 7T.

    Science.gov (United States)

    van de Bank, B L; Voogt, I J; Italiaander, M; Stehouwer, B L; Boer, V O; Luijten, P R; Klomp, D W J

    2013-04-01

    There is a need to obtain higher specificity in the detection of breast lesions using MRI. To address this need, Dynamic Contrast-Enhanced (DCE) MRI has been combined with other structural and functional MRI techniques. Unfortunately, owing to time constraints structural images at ultra-high spatial resolution can generally not be obtained during contrast uptake, whereas the relatively low spatial resolution of functional imaging (e.g. diffusion and perfusion) limits the detection of small lesions. To be able to increase spatial as well as temporal resolution simultaneously, the sensitivity of MR detection needs to increase as well as the ability to effectively accelerate the acquisition. The required gain in signal-to-noise ratio (SNR) can be obtained at 7T, whereas acceleration can be obtained with high-density receiver coil arrays. In this case, morphological imaging can be merged with DCE-MRI, and other functional techniques can be obtained at higher spatial resolution, and with less distortion [e.g. Diffusion Weighted Imaging (DWI)]. To test the feasibility of this concept, we developed a unilateral breast coil for 7T. It comprises a volume optimized dual-channel transmit coil combined with a 30-channel receive array coil. The high density of small coil elements enabled efficient acceleration in any direction to acquire ultra high spatial resolution MRI of close to 0.6 mm isotropic detail within a temporal resolution of 69 s, high spatial resolution MRI of 1.5 mm isotropic within an ultra high temporal resolution of 6.7 s and low distortion DWI at 7T, all validated in phantoms, healthy volunteers and a patient with a lesion in the right breast classified as Breast Imaging Reporting and Data System (BI-RADS) IV. Copyright © 2012 John Wiley & Sons, Ltd.

  6. High-Resolution X-ray Emission and X-ray Absorption Spectroscopy

    NARCIS (Netherlands)

    Groot, F.M.F. de

    2000-01-01

    In this review, high-resolution X-ray emission and X-ray absorption spectroscopy will be discussed. The focus is on the 3d transition-metal systems. To understand high-resolution X-ray emission and reso-nant X-ray emission, it is first necessary to spend some time discussing the X-ray absorption

  7. High-resolution flurescence spectroscopy in immunoanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Grubor, Nenad M. [Iowa State Univ., Ames, IA (United States)

    2005-01-01

    The work presented in this dissertation combines highly sensitive and selective fluorescence line-narrowing spectroscopy (FLNS) detection with various modes of immunoanalytical techniques. It has been shown that FLNS is capable of directly probing molecules immunocomplexed with antibodies, eliminating analytical ambiguities that may arise from interferences that accompany traditional immunochemical techniques. Moreover, the utilization of highly cross-reactive antibodies for highly specific analyte determination has been demonstrated. Finally, they demonstrate the first example of the spectral resolution of diastereomeric analytes based on their interaction with a cross-reactive antibody.

  8. Cardiac MRI. T2-mapping versus T2-weighted dark-blood TSE imaging for myocardial edema visualization in acute myocardial infarction

    International Nuclear Information System (INIS)

    Nassenstein, K.; Nensa, F.; Schlosser, T.; Umutlu, L.; Lauenstein, T.; Bruder, O.; Maderwald, S.; Ladd, M.E.

    2014-01-01

    Purpose: To assess the diagnostic accuracy of T2 mapping for the detection of myocardial edema in acute myocardial infarction (AMI), and to compare this diagnostic accuracy with that of the current standard for myocardial edema imaging, which is T2w dark-blood TSE imaging. Materials and Methods: 29 patients with AMI were examined at 1.5 T. For the visualization of myocardial edema, T2 maps, calculated from three T2w SSFP images, and T2w dark-blood TSE images were acquired in standard short- and long-axis views. Cine SSFP images were acquired for the analysis of left ventricular (LV) function and late gadolinium enhancement images (LGE) for the visualization of myocardial necrosis. The T2 maps as well as the T2w dark-blood TSE images were evaluated twice independently from the cine SSFP and LGE images. The presence or absence of myocardial edema was rated visually for each LV segment. As the standard of reference, the infarct zone was defined based on the cine SSFP and the LGE images. Results: In this segment-based analysis, T2 mapping showed a sensitivity of 82 % and a specificity of 94 % for the detection of edema in the infarct zone. T2w dark-blood TSE imaging revealed a sensitivity of 50 % and a specificity of 98 %. T2 mapping showed a higher intra-rater agreement compared to T2w dark-blood TSE imaging (κ: 0.87 vs. 0.76). Conclusions: T2 mapping allows for the visualization of myocardial edema in AMI with a high sensitivity and specificity, and features better diagnostic accuracy in terms of a higher sensitivity compared to T2w dark-blood TSE imaging. (orig.)

  9. Dobutamine cardiovascular magnetic resonance for the detection of myocardial ischemia with the use of myocardial tagging.

    Science.gov (United States)

    Kuijpers, Dirkjan; Ho, Kai Yiu J A M; van Dijkman, Paul R M; Vliegenthart, Rozemarijn; Oudkerk, Matthijs

    2003-04-01

    The purpose of this study was to assess the value of high-dose dobutamine cardiovascular magnetic resonance (CMR) with myocardial tagging for the detection of wall motion abnormalities as a measure of myocardial ischemia in patients with known or suspected coronary artery disease. Two hundred eleven consecutive patients with chest pain underwent dobutamine-CMR 4 days after antianginal medication was stopped. Dobutamine-CMR was performed at rest and during increasing doses of dobutamine. Cine-images were acquired during breath-hold with and without myocardial tagging at 3 short-axis levels. Regional wall motion was assessed in a 16-segment short-axis model. Patients with new wall motion abnormalities (NWMA) were examined by coronary angiography. Dobutamine-CMR was successfully performed in 194 patients. Dobutamine-CMR without tagging detected NWMA in 58 patients, whereas NWMA were detected in 68 patients with tagging (P=0.002, McNemar). Coronary angiography showed coronary artery disease in 65 (96%) of these 68 patients. All but 3 of the 65 patients needed revascularization. In the 112 patients with a negative dobutamine-CMR study, without baseline wall motion abnormalities, the cardiovascular occurrence-free survival rate was 98.2% during the mean follow-up period of 17.3 months (range, 7 to 31). Dobutamine-CMR with myocardial tagging detected more NWMA compared with dobutamine-CMR without tagging and reliably separated patients with a normal life expectancy from those at increased risk of major adverse cardiac events.

  10. Development of a high-resolution cavity-beam position monitor

    Directory of Open Access Journals (Sweden)

    Yoichi Inoue

    2008-06-01

    Full Text Available We have developed a high-resolution cavity-beam position monitor (BPM to be used at the focal point of the ATF2, which is a test beam line that is now being built to demonstrate stable orbit control at ∼nanometer resolution. The design of the cavity structure was optimized for the Accelerator Test Facility (ATF beam in various ways. For example, the cavity has a rectangular shape in order to isolate two dipole modes in orthogonal directions, and a relatively thin gap that is less sensitive to trajectory inclination. A two stage homodyne mixer with highly sensitive electronics and phase-sensitive detection was also developed. Two BPM blocks, each containing two cavity BPMs, were installed in the existing ATF beam line using a rigid support frame. After testing the basic characteristics, we measured the resolution using three BPMs. The system demonstrated 8.7 nm position resolution over a dynamic range of 5  μm.

  11. Development of a high-resolution cavity-beam position monitor

    Science.gov (United States)

    Inoue, Yoichi; Hayano, Hitoshi; Honda, Yosuke; Takatomi, Toshikazu; Tauchi, Toshiaki; Urakawa, Junji; Komamiya, Sachio; Nakamura, Tomoya; Sanuki, Tomoyuki; Kim, Eun-San; Shin, Seung-Hwan; Vogel, Vladimir

    2008-06-01

    We have developed a high-resolution cavity-beam position monitor (BPM) to be used at the focal point of the ATF2, which is a test beam line that is now being built to demonstrate stable orbit control at ˜nanometer resolution. The design of the cavity structure was optimized for the Accelerator Test Facility (ATF) beam in various ways. For example, the cavity has a rectangular shape in order to isolate two dipole modes in orthogonal directions, and a relatively thin gap that is less sensitive to trajectory inclination. A two stage homodyne mixer with highly sensitive electronics and phase-sensitive detection was also developed. Two BPM blocks, each containing two cavity BPMs, were installed in the existing ATF beam line using a rigid support frame. After testing the basic characteristics, we measured the resolution using three BPMs. The system demonstrated 8.7 nm position resolution over a dynamic range of 5μm.

  12. Classification of high resolution satellite images

    OpenAIRE

    Karlsson, Anders

    2003-01-01

    In this thesis the Support Vector Machine (SVM)is applied on classification of high resolution satellite images. Sveral different measures for classification, including texture mesasures, 1st order statistics, and simple contextual information were evaluated. Additionnally, the image was segmented, using an enhanced watershed method, in order to improve the classification accuracy.

  13. High-resolution and high-throughput multichannel Fourier transform spectrometer with two-dimensional interferogram warping compensation

    Science.gov (United States)

    Watanabe, A.; Furukawa, H.

    2018-04-01

    The resolution of multichannel Fourier transform (McFT) spectroscopy is insufficient for many applications despite its extreme advantage of high throughput. We propose an improved configuration to realise both performance using a two-dimensional area sensor. For the spectral resolution, we obtained the interferogram of a larger optical path difference by shifting the area sensor without altering any optical components. The non-linear phase error of the interferometer was successfully corrected using a phase-compensation calculation. Warping compensation was also applied to realise a higher throughput to accumulate the signal between vertical pixels. Our approach significantly improved the resolution and signal-to-noise ratio by factors of 1.7 and 34, respectively. This high-resolution and high-sensitivity McFT spectrometer will be useful for detecting weak light signals such as those in non-invasive diagnosis.

  14. A new method for high-resolution characterization of hydraulic conductivity

    Science.gov (United States)

    Liu, Gaisheng; Butler, J.J.; Bohling, Geoffrey C.; Reboulet, Ed; Knobbe, Steve; Hyndman, D.W.

    2009-01-01

    A new probe has been developed for high-resolution characterization of hydraulic conductivity (K) in shallow unconsolidated formations. The probe was recently applied at the Macrodispersion Experiment (MADE) site in Mississippi where K was rapidly characterized at a resolution as fine as 0.015 m, which has not previously been possible. Eleven profiles were obtained with K varying up to 7 orders of magnitude in individual profiles. Currently, high-resolution (0.015-m) profiling has an upper K limit of 10 m/d; lower-resolution (???0.4-m) mode is used in more permeable zones pending modifications. The probe presents a new means to help address unresolved issues of solute transport in heterogeneous systems. Copyright 2009 by the American Geophysical Union.

  15. Myocardial protection in heart surgery.

    Science.gov (United States)

    Mentzer, Robert M

    2011-01-01

    One of the unmet clinical needs in heart surgery is the prevention of myocardial stunning and necrosis that occurs as a result of ischemia-reperfusion. Myocardial stunning, a frequent consequence after heart surgery, is characterized by a requirement for postoperative inotropic support despite a technically satisfactory heart operation. In high-risk patients with marginal cardiac reserve, stunning is a major cause of prolonged critical care and may be associated with as much as a 5-fold increase in mortality. In contrast, the frequency of myocardial necrosis (myocardial infarction [MI]) after cardiac surgery is less appreciated and its consequences are much more subtle. The consequences may not be apparent for months to years. While we now have a much better understanding of the molecular mechanisms underlying myocardial stunning and MI, we still have no effective way to prevent these complications, nor a consistently effective means to engage the well-studied endogenous mechanisms of cardioprotection. The failure to develop clinically effective interventions is multifactorial and can be attributed to reliance on findings obtained from subcellular and cellular studies, to drawing conclusions from preclinical large animal studies that have been conducted in a disease-free state, and to accepting less than robust surrogate markers of injury in phase II clinical trials. These factors also explain the disappointing failure to identify effective adjuvant therapy in the setting of percutaneous coronary revascularization for acute MI (AMI) and reperfusion injury. These issues have contributed to the disappointing outcomes of large and costly phase III trials, resulting in a lack of enthusiasm on the part of the pharmaceutical industry to engage in further drug development for this indication. The purpose of this review is to (1) define the scope of the clinical problem; (2) summarize the outcomes of selected phases II and III clinical trials; and (3) identify the gap that

  16. Evaluation of myocardial involvement in Duchenne's progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Kawai, Naoki; Sotobata, Iwao; Okada, Mitsuhiro

    1985-01-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. A qualitative analysis was performed from five projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in the LV posterolateral or posterior wall (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle involvements or thoracic deformities assessed by transmission computed tomography. Extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. Progression of the myocardial scintigraphic abnormalities were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies over 2 to 3 years. It was concluded that thallium myocardial perfusion imaging is a useful clinical technique to assess myocardial involvement in Duchenne's progressive muscular dystrophy. (author)

  17. Evaluation of a High-Resolution Regional Reanalysis for Europe

    Science.gov (United States)

    Ohlwein, C.; Wahl, S.; Keller, J. D.; Bollmeyer, C.

    2014-12-01

    Reanalyses gain more and more importance as a source of meteorological information for many purposes and applications. Several global reanalyses projects (e.g., ERA, MERRA, CSFR, JMA9) produce and verify these data sets to provide time series as long as possible combined with a high data quality. Due to a spatial resolution down to 50-70km and 3-hourly temporal output, they are not suitable for small scale problems (e.g., regional climate assessment, meso-scale NWP verification, input for subsequent models such as river runoff simulations). The implementation of regional reanalyses based on a limited area model along with a data assimilation scheme is able to generate reanalysis data sets with high spatio-temporal resolution. Within the Hans-Ertel-Centre for Weather Research (HErZ), the climate monitoring branch concentrates efforts on the assessment and analysis of regional climate in Germany and Europe. In joint cooperation with DWD (German Meteorological Service), a high-resolution reanalysis system based on the COSMO model has been developed. The regional reanalysis for Europe matches the domain of the CORDEX EURO-11 specifications, albeit at a higher spatial resolution, i.e., 0.055° (6km) instead of 0.11° (12km) and comprises the assimilation of observational data using the existing nudging scheme of COSMO complemented by a special soil moisture analysis with boundary conditions provided by ERA-Interim data. The reanalysis data set covers 6 years (2007-2012) and is currently extended to 16 years. Extensive evaluation of the reanalysis is performed using independent observations with special emphasis on precipitation and high-impact weather situations indicating a better representation of small scale variability. Further, the evaluation shows an added value of the regional reanalysis with respect to the forcing ERA Interim reanalysis and compared to a pure high-resolution dynamical downscaling approach without data assimilation.

  18. Histochemical and immunohistochemical analyses of the myocardial scar fallowing acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Tatić Vujadin

    2012-01-01

    Full Text Available Background/Aim. The heart has traditionally been considered as a static organ without capacity of regeneration after trauma. Currently, the more and more often asked question is whether the heart has any intrinsic capacities to regenerate myocytes after myocardial infarction. The aim of this study was to present the existence of the preserved muscle fibers in the myocardial scar following myocardial infarction as well as the presence of numerous cells of various size and form that differently reacted to the used immunohistochemical antibodies. Methods. Histological, histochemical and immunohistochemical analyses of myocardial sections taken from 177 patients who had died of acute myocardial infarction and had the myocardial scar following myocardial infarction, were carried out. More sections taken both from the site of acute infarction and scar were examined by the following methods: hematoxylin-eosin (HE, periodic acid schiff (PAS, PAS-diastasis, Masson trichrom, Malory, van Gieson, vimentin, desmin, myosin, myoglobin, alpha actin, smoth muscle actin (SMA, p53, leukocyte common antigen (LCA, proliferating cell nuclear antigen (PCNA, Ki-67, actin HHF35, CD34, CD31, CD45, CD45Ro, CD8, CD20. Results. In all sections taken from the scar region, larger or smaller islets of the preserved muscle fibers with the signs of hypertrophy were found. In the scar, a large number of cells of various size and form: spindle, oval, elongated with abundant cytoplasm, small with one nucleus and cells with scanty cytoplasm, were found. The present cells differently reacted to histochemical and immunohistochemical methods. Large oval cells showed negative reaction to lymphocytic and leukocytic markers, and positive to alpha actin, actin HHF35, Ki-67, myosin, myoglobin and desmin. Elongated cells were also positive to those markers. Small mononuclear cells showed positive reaction to lymphocytic markers. Endothelial and smooth muscle cells in the blood vessel walls

  19. Fatty acid myocardial imaging using 123I-β-methyl-iophenyl pentadecanoic acid (BMIPP): Comparison of myocardial perfusion and fatty acid utilization in canine myocardial infarction

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Sago, Masayoshi; Kihara, Koichi; Oka, Hisashi; Shimonagata, Tsuyoshi; Katabuchi, Tetsuro; Hayashi, Makoto; Uehara, Toshiisa; Hayashida, Kohei; Noda, Hiroyuki; Takano, Hisateru

    1989-01-01

    To evaluate the relationship between myocardial perfusion and fatty acid metabolism in canine myocardial infarction, 16 dogs were studied using thallium and 123 I-β-methyl-iodophenyl pentadecanoic acid (BMIPP). Eight dogs (group A) had left anterior coronary arterial occlusion (6 h ligation), 6 dogs (group B) had reperfusion (3 h ligation and 1 h reperfusion) and 2 dogs served as the normal control. Myocardial imaging with BMIPP was excellent, owing to its higher uptake and longer retention in myocardium and rapid blood disappearance in addition to diminished liver and lung uptake. The mean half time value which was generated from the BMIPP myocardial washout curve, was significantly larger in the reperfused myocardium. The gamma camera imaging showed uncoupling of BMIPP and thallium (BMIPP uptake greater than thallium uptake) in five dogs in group B. On the other hand, all dogs in group A had a persistent defect in BMIPP and thallium uptake. Our findings indicate that the combination of BMIPP and thallium for myocardial imaging supply different information about the zone of infarction and ischemia, which may be useful for the assessment of myocardial viability. (orig.)

  20. High resolution satellite imagery : from spies to pipeline management

    Energy Technology Data Exchange (ETDEWEB)

    Adam, S. [Canadian Geomatic Solutions Ltd., Calgary, AB (Canada); Farrell, M. [TransCanada Transmission, Calgary, AB (Canada)

    2000-07-01

    The launch of Space Imaging's IKONOS satellite in September 1999 has opened the door for corridor applications. The technology has been successfully implemented by TransCanada PipeLines in mapping over 1500 km of their mainline. IKONOS is the world's first commercial high resolution satellite which collects data at 1-meter black/white and 4-meter multi-spectral. Its use is regulated by the U.S. government. It is the best source of high resolution satellite image data. Other sources include the Indian Space Agency's IRS-1 C/D satellite and the Russian SPIN-2 which provides less reliable coverage. In addition, two more high resolution satellites may be launched this year to provide imagery every day of the year. IKONOS scenes as narrow as 5 km can be purchased. TransCanada conducted a pilot study to determine if high resolution satellite imagery is as effective as ortho-photos for identifying population structures within a buffer of TransCanada's east line right-of-way. The study examined three unique segments where residential, commercial, industrial and public features were compared. It was determined that IKONOS imagery is as good as digital ortho-photos for updating structures from low to very high density areas. The satellite imagery was also logistically easier than ortho-photos to acquire. This will be even more evident when the IKONOS image archives begins to grow. 4 tabs., 3 figs.

  1. Pseudo-dissection of ascending aorta in inferior myocardial infarction.

    Directory of Open Access Journals (Sweden)

    Grahame K. Goode

    2011-06-01

    Full Text Available Acute aortic dissection is a cardiac emergency which can present as inferior myocardial infarction. It has high morbidity and mortality requiring prompt diagnosis and treatment. Rapid advances in noninvasive imaging modalities have facilitated the early diagnosis of this condition and in ruling out this potentially catastrophic illness. We report an interesting case of a 57 year- old -man who presented with inferior myocardial infarction requiring thrombolysis and temporary pacing wire for complete heart block. An echocardiogram was highly suspicious of aortic dissection. CT scan confirmed that the malposition of the temporary pacing wire through the aorta mimicked aortic dissection.

  2. High resolution radar satellite imagery analysis for safeguards applications

    Energy Technology Data Exchange (ETDEWEB)

    Minet, Christian; Eineder, Michael [German Aerospace Center, Remote Sensing Technology Institute, Department of SAR Signal Processing, Wessling, (Germany); Rezniczek, Arnold [UBA GmbH, Herzogenrath, (Germany); Niemeyer, Irmgard [Forschungszentrum Juelich, Institue of Energy and Climate Research, IEK-6: Nuclear Waste Management and Reactor Safety, Juelich, (Germany)

    2011-12-15

    For monitoring nuclear sites, the use of Synthetic Aperture Radar (SAR) imagery shows essential promises. Unlike optical remote sensing instruments, radar sensors operate under almost all weather conditions and independently of the sunlight, i.e. time of the day. Such technical specifications are required both for continuous and for ad-hoc, timed surveillance tasks. With Cosmo-Skymed, TerraSARX and Radarsat-2, high-resolution SAR imagery with a spatial resolution up to 1m has recently become available. Our work therefore aims to investigate the potential of high-resolution TerraSAR data for nuclear monitoring. This paper focuses on exploiting amplitude of a single acquisition, assessing amplitude changes and phase differences between two acquisitions, and PS-InSAR processing of an image stack.

  3. 'Motion frozen' quantification and display of myocardial perfusion gated SPECT

    International Nuclear Information System (INIS)

    Slomka, P.J.; Hurwitz, G.A.; Baddredine, M.; Baranowski, J.; Aladl, U.E.

    2002-01-01

    Aim: Gated SPECT imaging incorporates both functional and perfusion information of the left ventricle (LV). However perfusion data is confounded by the effect of ventricular motion. Most existing quantification paradigms simply add all gated frames and then proceed to extract the perfusion information from static images, discarding the effects of cardiac motion. In an attempt to improve the reliability and accuracy of cardiac SPECT quantification we propose to eliminate the LV motion prior to the perfusion quantification via automated image warping algorithm. Methods: A pilot series of 14 male and 11 female gated stress SPECT images acquired with 8 time bins have been co-registered to the coordinates of the 3D normal templates. Subsequently the LV endo and epi-cardial 3D points (300-500) were identified on end-systolic (ES) and end-diastolic (ED) frames, defining the ES-ED motion vectors. The nonlinear image warping algorithm (thin-plate-spline) was then applied to warp end-systolic frame was onto the end-diastolic frames using the corresponding ES-ED motion vectors. The remaining 6 intermediate frames were also transformed to the ED coordinates using fractions of the motion vectors. Such warped images were then summed to provide the LV perfusion image in the ED phase but with counts from the full cycle. Results: The identification of the ED/ES corresponding points was successful in all cases. The corrected displacement between ED and ES images was up to 25 mm. The summed images had the appearance of the ED frames but have been much less noisy since all the counts have been used. The spatial resolution of such images appeared higher than that of summed gated images, especially in the female scans. These 'motion frozen' images could be displayed and quantified as regular non-gated tomograms including polar map paradigm. Conclusions: This image processing technique may improve the effective image resolution of summed gated myocardial perfusion images used for

  4. Effects of display resolution and size on primary diagnosis of chest images using a high-resolution electronic work station

    International Nuclear Information System (INIS)

    Fuhrman, C.R.; Cooperstein, L.A.; Herron, J.; Good, W.F.; Good, B.; Gur, D.; Maitz, G.; Tabor, E.; Hoy, R.J.

    1987-01-01

    To evaluate the acceptability of electronically displayed planar images, the authors have a high-resolution work station. This system utilizes a high-resolution film digitizer (100-micro resolution) interfaced to a mainframe computer and two high-resolution (2,048 X 2,048) display devices (Azuray). In a clinically simulated multiobserver blind study (19 cases and five observers) a prodetermined series of reading sessions is stored on magnetic disk and is transferred to the displays while the preceding set of images is being reviewed. Images can be linearly processed on the fly into 2,000 X 2,000 full resolution, 1,000 X 1,000 minified display, or 1,000 X 1,000 interpolated for full-size display. Results of the study indicate that radiologists accept but do not like significant minification (more than X2), and they rate 2,000 X 2,000 images as having better diagnostic quality than 1,000 X 1,000 images

  5. Myocardial scintigraphy with thallium-201

    International Nuclear Information System (INIS)

    Schwaiger, M.; Silber, S.; Klein, U.; Rudolph, W.

    1980-01-01

    Thallium-201 myocardial scintigraphy is an important non-invasive method for assessment of coronary artery disease. Other applications of the method such as delineation of the right ventricular free wall in right ventricular overload, or the detection of hypertrophic cardiomyopathies or myocardial infiltrations are of subordinate importance. In heart disease such as congestive cardiomyopathy and mitral valve prolapse thallium-201 uptake defects have been described, the clinical implications of these findings, however, cannot be adequately interpreted at this time. Myocardial uptake of thallium-201 is an active process, dependent on and proportional to perfusion. Differentiation between myocardial ischemia and myocardial scar is based on the presence or absence of thallium-201 'redistribution'. That is, in the presence of acute reversible ischemia there is increased thallium-201 uptake in the post-ischemic phase in previously hypoperfused myocardium and, subsequently, equilibrium of the initially registered activity differences. 'Redistribution' has also been described in the resting scintigram of patients with severe coronary artery disease and chronic hypoperfusion. (orig.) [de

  6. Quantitative assessment of myocardial blood flow by measurement of fractional myocardial uptake of 201Tl

    International Nuclear Information System (INIS)

    Yonekura, Yoshiharu; Ishii, Yasushi; Torizuka, Kanji; Kadota, Kazunori; Kambara, Hirofumi

    1980-01-01

    Fractional Myocardial uptake of 201 Tl was measured for the quantitative assessment of myocardial blood flow in coronary artery disease (CAD). 10 normals and 28 CAD, 7 of which have less than 50% stenosis (CAD I) and 21 of which have more than 50% stenosis (CAD II) in the proximal portion of coronary arteries, were studied at rest and with submaximal exercise loading by bicycle ergometer. After intravenous injection of 201 Tl, its rapid transport process was recorded during the initial 5 minutes by a scintillation camera and a minicomputer. Total injected dosage (T) was obtained from the counts of the entire chest region during the initial passage of the tracer through the heart and lung. Myocardial uptake (M) was counted with the same geometry from the subsequent accumulation within the myocardial region with subtraction of the background activities in the upper mediastinal region (B). The fractional myocardial uptake of 201 Tl ((M-B)/T) is assumed to be proportional to the fractional myocardial blood flow to cardiac output (MBF/CO) according to the indicator fractionation principle. The average value of MBF/CO at rest in CAD (4.11 +- 1.12%) was significantly greater than in normals (3.36 +- 0.49%), which may be caused by an increased left ventricular mass in CAD. Change rate of MBF/CO on the exercise loading was significantly less in CAD I (1.36 +- 0.14) and in CAD II (1.11 +- 0.21) than in normals (1.75 +- 0.11). MBF/CO increased proportionally to the increment of the double product of heart rate and systolic blood pressure by exercise loading in normals, whereas it didn't in CAD. The sensitivity of this method was superior to the stress electrocardiogram and the stress myocardial perfusion imaging, not only in CAD II but also in CAD I. This result indicated that this type of global assessment of the myocardial reserve capacity is valuable in addition to the simple stress myocardial perfusion imaging. (author)

  7. High-resolution phylogenetic microbial community profiling

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Esther; Coleman-Derr, Devin; Bowman, Brett; Schwientek, Patrick; Clum, Alicia; Copeland, Alex; Ciobanu, Doina; Cheng, Jan-Fang; Gies, Esther; Hallam, Steve; Tringe, Susannah; Woyke, Tanja

    2014-03-17

    The representation of bacterial and archaeal genome sequences is strongly biased towards cultivated organisms, which belong to merely four phylogenetic groups. Functional information and inter-phylum level relationships are still largely underexplored for candidate phyla, which are often referred to as microbial dark matter. Furthermore, a large portion of the 16S rRNA gene records in the GenBank database are labeled as environmental samples and unclassified, which is in part due to low read accuracy, potential chimeric sequences produced during PCR amplifications and the low resolution of short amplicons. In order to improve the phylogenetic classification of novel species and advance our knowledge of the ecosystem function of uncultivated microorganisms, high-throughput full length 16S rRNA gene sequencing methodologies with reduced biases are needed. We evaluated the performance of PacBio single-molecule real-time (SMRT) sequencing in high-resolution phylogenetic microbial community profiling. For this purpose, we compared PacBio and Illumina metagenomic shotgun and 16S rRNA gene sequencing of a mock community as well as of an environmental sample from Sakinaw Lake, British Columbia. Sakinaw Lake is known to contain a large age of microbial species from candidate phyla. Sequencing results show that community structure based on PacBio shotgun and 16S rRNA gene sequences is highly similar in both the mock and the environmental communities. Resolution power and community representation accuracy from SMRT sequencing data appeared to be independent of GC content of microbial genomes and was higher when compared to Illumina-based metagenome shotgun and 16S rRNA gene (iTag) sequences, e.g. full-length sequencing resolved all 23 OTUs in the mock community, while iTags did not resolve closely related species. SMRT sequencing hence offers various potential benefits when characterizing uncharted microbial communities.

  8. Analysis strategies for high-resolution UHF-fMRI data.

    Science.gov (United States)

    Polimeni, Jonathan R; Renvall, Ville; Zaretskaya, Natalia; Fischl, Bruce

    2018-03-01

    Functional MRI (fMRI) benefits from both increased sensitivity and specificity with increasing magnetic field strength, making it a key application for Ultra-High Field (UHF) MRI scanners. Most UHF-fMRI studies utilize the dramatic increases in sensitivity and specificity to acquire high-resolution data reaching sub-millimeter scales, which enable new classes of experiments to probe the functional organization of the human brain. This review article surveys advanced data analysis strategies developed for high-resolution fMRI at UHF. These include strategies designed to mitigate distortion and artifacts associated with higher fields in ways that attempt to preserve spatial resolution of the fMRI data, as well as recently introduced analysis techniques that are enabled by these extremely high-resolution data. Particular focus is placed on anatomically-informed analyses, including cortical surface-based analysis, which are powerful techniques that can guide each step of the analysis from preprocessing to statistical analysis to interpretation and visualization. New intracortical analysis techniques for laminar and columnar fMRI are also reviewed and discussed. Prospects for single-subject individualized analyses are also presented and discussed. Altogether, there are both specific challenges and opportunities presented by UHF-fMRI, and the use of proper analysis strategies can help these valuable data reach their full potential. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. A High-Resolution Stopwatch for Cents

    Science.gov (United States)

    Gingl, Z.; Kopasz, K.

    2011-01-01

    A very low-cost, easy-to-make stopwatch is presented to support various experiments in mechanics. The high-resolution stopwatch is based on two photodetectors connected directly to the microphone input of a sound card. Dedicated free open-source software has been developed and made available to download. The efficiency is demonstrated by a free…

  10. [Clinical significance of myocardial 123I-BMIPP imaging in patients with myocardial infarction].

    Science.gov (United States)

    Narita, M; Kurihara, T; Shindoh, T; Honda, M

    1997-03-01

    In order to clarify the characteristics of fatty acid metabolism in patients with myocardial infarction (MI), we performed myocardial imaging with 123I-beta-methyl-p-iodophenylpentadecanoic acid (BMIPP) and we compared these findings with exercise stress (Ex) and resting myocardial perfusion imaging with 99mTc-methoxyisobutylisonitrile (MIBI) and left ventricular wall motion index (WMI) which were obtained by left ventriculography. We studied 55 patients with MI, 14 patients with recent MI (RMI) and 41 patients with old MI (OMI), and myocardial images were divided into 17 segments and myocardial uptake of the radionuclide was graded from 0 (normal) to 3 (maximal abnormality). In 28 patients we compared segmental defect score (SDS) with WMI which were obtained by centerline method at the corresponded segments. As a whole, the mean total defect scores (TDSs) of BMIPP and Ex were similar and they were greater than the mean TDS of resting perfusion. In 30 patient (55%) TDS of BMIPP was greater than that of TDS of resting perfusion. In 24 patients perfusion abnormality developed by Ex and the location of BMIPP abnormality coincided with the abnormality of Ex. But in the other 6 patients Ex did not induce any abnormality and they were all RMI and infarcted coronary artery was patent. However in the group with TDS of BMIPP identical to TDS of resting perfusion (25 patients), 92% did not show myocardial perfusion abnormality after Ex. In the comparison of SDS and WMI, myocardial segments were divided into 3 groups; both SDSs of BMIPP and resting perfusion were normal or borderline abnormality (Group 1, 82 segments), SDS of resting perfusion was normal or borderline and SDS of BMIPP was definitely abnormal (Group 2, 10 segments) and both SDSs of BMIPP and resting perfusion were definitely abnormal (Group 3, 48 segments). In Group 1, WMS (-0.41 +/- 0.77) was significantly (p acid metabolism may appear in viable myocardium such as jeopardized myocardium and myocardium which

  11. Ring artifact correction for high-resolution micro CT

    International Nuclear Information System (INIS)

    Kyriakou, Yiannis; Prell, Daniel; Kalender, Willi A

    2009-01-01

    In high-resolution micro CT using flat detectors (FD), imperfect or defect detector elements may cause concentric-ring artifacts due to their continuous over- or underestimation of attenuation values, which often disturb image quality. We here present a dedicated image-based ring artifact correction method for high-resolution micro CT, based on median filtering of the reconstructed image and working on a transformed version of the reconstructed images in polar coordinates. This post-processing method reduced ring artifacts in the reconstructed images and improved image quality for phantom and in in vivo scans. Noise and artifacts were reduced both in transversal and in multi-planar reformations along the longitudinal axis. (note)

  12. Evaluation of myocardial abnormalities in patients with collagen diseases by thallium-201 myocardial scintigram

    Energy Technology Data Exchange (ETDEWEB)

    Yamano, Shigeru (Nara Medical Univ., Kashihara (Japan))

    1992-08-01

    This study was performed to evaluate myocardial lesions in patients with collagen diseases by rest and exercise thallium-201 myocardial scintigraphies. A total of 76 patients without ischemic ECG changes, consisting of 27 cases of systemic lupus erythematosus (SLE), 17 cases of polymyositis or dermatomyositis (PM[center dot]DM), 11 cases of progressive systemic sclerosis (PSS), and 21 cases of Sjoegren's syndrome (SjS), were enrolled in this study. Reversible exercise-induced defects suggesting myocardial ischemia were noted in 12 cases of SLE, 5 cases of PM[center dot]DM, 3 cases of PSS, and 3 cases of SjS. Of the 23 patients who had exercise-induced defects, 9 patients showed normal coronary angiograms by cardiac catheterization. Fixed hypoperfusion areas were observed in 5 cases of SLE, 6 cases of PM[center dot]DM, 4 cases of PSS and 3 cases of SjS. Rest thallium-201 myocardial scintigraphy disclosed hypoperfusion areas, which were not induced by exercise, in 1 case of SLE, 4 cases of PM[center dot]DM, 1 case of PSS and 5 cases of SjS. Endomyocardial biopsy was performed on 20 patients. Myocardial lesions in PM[center dot]DM and PSS were more severe and wide spread than in SLE. Ejection fraction and fractional shortening evaluated by echocardiography had no significant differences between each disease group and the healthy control group. These findings suggest that patients with collagen diseases show the presence of abnormalities of coronary circulation at the level of the intramyocardial vasculature in the stage before impairment of cardiac function, myocardial fibrosis and functional abnormalities of the cell membrane level that were not dependent on myocardial ischemia. (author).

  13. Digital approach to high-resolution pulse processing for semiconductor detectors

    International Nuclear Information System (INIS)

    Georgiev, A.; Buchner, A.; Gast, W.; Lieder, R.M.

    1992-01-01

    A new design philosophy for processing signals produced by high resolution, large volume semiconductor detectors is described. These detectors, to be used in the next generation of spectrometer arrays for nuclear research (i.e. EUROBALL, etc.), present a set of problems like resolution degradation due to charge trapping and ballistic defect effects, low resolution at a high count rate, poor long term stability, etc. To solve these problems, a new design approach has been developed, including reconstruction of the event charge, providing a pure triangular residual function, and suppressing low frequency noise. 5 refs., 4 figs

  14. Digital approach to high-resolution pulse processing for semiconductor detectors

    Energy Technology Data Exchange (ETDEWEB)

    Georgiev, A [Sofia Univ. (Bulgaria); Buchner, A [Forschungszentrum Rossendorf (Germany); Gast, W; Lieder, R M [Forschungszentrum Juelich GmbH (Germany). Inst. fuer Kernphysik; Stein, J [Target System Electronic GmbH, Solingen, (Germany)

    1992-08-01

    A new design philosophy for processing signals produced by high resolution, large volume semiconductor detectors is described. These detectors, to be used in the next generation of spectrometer arrays for nuclear research (i.e. EUROBALL, etc.), present a set of problems like resolution degradation due to charge trapping and ballistic defect effects, low resolution at a high count rate, poor long term stability, etc. To solve these problems, a new design approach has been developed, including reconstruction of the event charge, providing a pure triangular residual function, and suppressing low frequency noise. 5 refs., 4 figs.

  15. The myocardial perfusion imaging of bone marrow mesenchymal stem cell transplantation treated acute myocardial infarction in pig

    International Nuclear Information System (INIS)

    He Miao; Hou Xiancun; Li Yaomei; Zhou Peng; Qi Chunmei; Wu Weihuan; Li Li

    2006-01-01

    Objective: To evaluate the clinical value of bone marrow mesenchymal stem cell transplantation on acute myocardial infarction in pig with myocardial perfusion imaging. Methods: Acute myocardial infarction models were established by 21 minitype Chinese pigs and were divided into two groups. After 10 days, experimental group (n=11) was transplanted with bone marrow mesenchymal stem cell at the infarct areas, and the control group (n=10) with incubation solution. Before and eight weeks after transplantation, both groups were examined by 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging and with semi-quantitative analysis. Besides, echocardiogram and immunohistochemistry were also performed. Results: There was significant difference of total myocardial perfusion abnormal segments (46 vs 26), infarct areas [(34±12)% vs (21±10)%] and myocardial ischemia score [(20.0±4.3) vs (12.1±3.6)] between two groups (P<0.05). Also, there were accordant results with echocardiogram and immunohistochemistry findings. Conclusions: Bone marrow mesenchymal stem cell transplantation may improve blood perfusion and viability of the ischemic areas: Myocardial perfusion imaging can accurately observe the survival of bone marrow mesenchymal stem cell transplanted at the infarct areas. (authors)

  16. Usefulness of myocardial parametric imaging to evaluate myocardial viability in experimental and in clinical studies.

    Science.gov (United States)

    Korosoglou, G; Hansen, A; Bekeredjian, R; Filusch, A; Hardt, S; Wolf, D; Schellberg, D; Katus, H A; Kuecherer, H

    2006-03-01

    To evaluate whether myocardial parametric imaging (MPI) is superior to visual assessment for the evaluation of myocardial viability. Myocardial contrast echocardiography (MCE) was assessed in 11 pigs before, during, and after left anterior descending coronary artery occlusion and in 32 patients with ischaemic heart disease by using intravenous SonoVue administration. In experimental studies perfusion defect area assessment by MPI was compared with visually guided perfusion defect planimetry. Histological assessment of necrotic tissue was the standard reference. In clinical studies viability was assessed on a segmental level by (1) visual analysis of myocardial opacification; (2) quantitative estimation of myocardial blood flow in regions of interest; and (3) MPI. Functional recovery between three and six months after revascularisation was the standard reference. In experimental studies, compared with visually guided perfusion defect planimetry, planimetric assessment of infarct size by MPI correlated more significantly with histology (r2 = 0.92 versus r2 = 0.56) and had a lower intraobserver variability (4% v 15%, p < 0.05). In clinical studies, MPI had higher specificity (66% v 43%, p < 0.05) than visual MCE and good accuracy (81%) for viability detection. It was less time consuming (3.4 (1.6) v 9.2 (2.4) minutes per image, p < 0.05) than quantitative blood flow estimation by regions of interest and increased the agreement between observers interpreting myocardial perfusion (kappa = 0.87 v kappa = 0.75, p < 0.05). MPI is useful for the evaluation of myocardial viability both in animals and in patients. It is less time consuming than quantification analysis by regions of interest and less observer dependent than visual analysis. Thus, strategies incorporating this technique may be valuable for the evaluation of myocardial viability in clinical routine.

  17. Enhancing GIS Capabilities for High Resolution Earth Science Grids

    Science.gov (United States)

    Koziol, B. W.; Oehmke, R.; Li, P.; O'Kuinghttons, R.; Theurich, G.; DeLuca, C.

    2017-12-01

    Applications for high performance GIS will continue to increase as Earth system models pursue more realistic representations of Earth system processes. Finer spatial resolution model input and output, unstructured or irregular modeling grids, data assimilation, and regional coordinate systems present novel challenges for GIS frameworks operating in the Earth system modeling domain. This presentation provides an overview of two GIS-driven applications that combine high performance software with big geospatial datasets to produce value-added tools for the modeling and geoscientific community. First, a large-scale interpolation experiment using National Hydrography Dataset (NHD) catchments, a high resolution rectilinear CONUS grid, and the Earth System Modeling Framework's (ESMF) conservative interpolation capability will be described. ESMF is a parallel, high-performance software toolkit that provides capabilities (e.g. interpolation) for building and coupling Earth science applications. ESMF is developed primarily by the NOAA Environmental Software Infrastructure and Interoperability (NESII) group. The purpose of this experiment was to test and demonstrate the utility of high performance scientific software in traditional GIS domains. Special attention will be paid to the nuanced requirements for dealing with high resolution, unstructured grids in scientific data formats. Second, a chunked interpolation application using ESMF and OpenClimateGIS (OCGIS) will demonstrate how spatial subsetting can virtually remove computing resource ceilings for very high spatial resolution interpolation operations. OCGIS is a NESII-developed Python software package designed for the geospatial manipulation of high-dimensional scientific datasets. An overview of the data processing workflow, why a chunked approach is required, and how the application could be adapted to meet operational requirements will be discussed here. In addition, we'll provide a general overview of OCGIS

  18. Efficacy and Safety of a Pharmaco-Invasive Strategy With Half-Dose Alteplase Versus Primary Angioplasty in ST-Segment-Elevation Myocardial Infarction: EARLY-MYO Trial (Early Routine Catheterization After Alteplase Fibrinolysis Versus Primary PCI in Acute ST-Segment-Elevation Myocardial Infarction).

    Science.gov (United States)

    Pu, Jun; Ding, Song; Ge, Heng; Han, Yaling; Guo, Jinchen; Lin, Rong; Su, Xi; Zhang, Heng; Chen, Lianglong; He, Ben

    2017-10-17

    Timely primary percutaneous coronary intervention (PPCI) cannot be offered to all patients with ST-segment-elevation myocardial infarction (STEMI). Pharmaco-invasive (PhI) strategy has been proposed as a valuable alternative for eligible patients with STEMI. We conducted a randomized study to compare the efficacy and safety of a PhI strategy with half-dose fibrinolytic regimen versus PPCI in patients with STEMI. The EARLY-MYO trial (Early Routine Catheterization After Alteplase Fibrinolysis Versus Primary PCI in Acute ST-Segment-Elevation Myocardial Infarction) was an investigator-initiated, prospective, multicenter, randomized, noninferiority trial comparing a PhI strategy with half-dose alteplase versus PPCI in patients with STEMI 18 to 75 years of age presenting ≤6 hours after symptom onset but with an expected PCI-related delay. The primary end point of the study was complete epicardial and myocardial reperfusion after PCI, defined as thrombolysis in myocardial infarction flow grade 3, thrombolysis in myocardial infarction myocardial perfusion grade 3, and ST-segment resolution ≥70%. We also measured infarct size and left ventricular ejection fraction with cardiac magnetic resonance and recorded 30-day clinical and safety outcomes. A total of 344 patients from 7 centers were randomized to PhI (n=171) or PPCI (n=173). PhI was noninferior (and even superior) to PPCI for the primary end point (34.2% versus 22.8%, P noninferiority <0.05, P superiority =0.022), with no significant differences in the frequency of the individual components of the combined end point: thrombolysis in myocardial infarction flow 3 (91.3% versus 89.2%, P =0.580), thrombolysis in myocardial infarction myocardial perfusion grade 3 (65.8% versus 62.9%, P =0.730), and ST-segment resolution ≥70% (50.9% versus 45.5%, P =0.377). Infarct size (23.3%±11.3% versus 25.8%±13.7%, P =0.101) and left ventricular ejection fraction (52.2%±11.0% versus 51.4%±12.0%, P =0.562) were similar in both

  19. Noninvasive assessment of canine myocardial oxidative metabolism with carbon-11 acetate and positron emission tomography

    International Nuclear Information System (INIS)

    Brown, M.A.; Myears, D.W.; Bergmann, S.R.

    1988-01-01

    Noninvasive quantification of regional myocardial metabolism would be highly desirable to evaluate pathogenetic mechanisms of heart disease and their response to therapy. It was previously demonstrated that the metabolism of radiolabeled acetate, a readily utilized myocardial substrate predominantly metabolized to carbon dioxide (CO2) by way of the tricarboxylic acid cycle, provides a good index of oxidative metabolism in isolated perfused rabbit hearts because of tight coupling between the tricarboxylic acid cycle and oxidative phosphorylation. In the present study, in a prelude to human studies, the relation between myocardial clearance of carbon-11 (11C)-labeled acetate and myocardial oxygen consumption was characterized in eight intact dogs using positron emission tomography. Anesthetized dogs were studied during baseline conditions and again during either high or low work states induced pharmacologically. High myocardial extraction and rapid blood clearance of tracer yielded myocardial images of excellent quality. The turnover (clearance) of 11C radioactivity from the myocardium was biexponential with the mean half-time of the dominant rapid phase averaging 5.4 +/- 2.2, 2.8 +/- 1.3 and 11.1 +/- 1.3 min in control, high and low work load studies, respectively. No significant difference was found between the rate of clearance of 11C radioactivity from the myocardium measured noninvasively with positron emission tomography and the myocardial efflux of 11CO2 measured directly from the coronary sinus. The rate of clearance of the 11C radioactivity from the heart correlated closely with myocardial oxygen consumption (r = 0.90, p less than 0.001) as well as with the rate-pressure product (r = 0.95, p less than 0.001). Hence, the rate of oxidation of 11C-acetate can be determined noninvasively with positron emission tomography, providing a quantitative index of oxidative metabolism under diverse conditions

  20. High resolution melting: improvements in the genetic diagnosis of hypertrophic cardiomyopathy in a Portuguese cohort

    Directory of Open Access Journals (Sweden)

    Santos Susana

    2012-03-01

    Full Text Available Abstract Background Hypertrophic Cardiomyopathy (HCM is a complex myocardial disorder with a recognized genetic heterogeneity. The elevated number of genes and mutations involved in HCM limits a gene-based diagnosis that should be considered of most importance for basic research and clinical medicine. Methodology In this report, we evaluated High Resolution Melting (HRM robustness, regarding HCM genetic testing, by means of analyzing 28 HCM-associated genes, including the most frequent 4 HCM-associated sarcomere genes, as well as 24 genes with lower reported HCM-phenotype association. We analyzed 80 Portuguese individuals with clinical phenotype of HCM allowing simultaneously a better characterization of this disease in the Portuguese population. Results HRM technology allowed us to identify 60 mutated alleles in 72 HCM patients: 49 missense mutations, 3 nonsense mutations, one 1-bp deletion, one 5-bp deletion, one in frame 3-bp deletion, one insertion/deletion, 3 splice mutations, one 5'UTR mutation in MYH7, MYBPC3, TNNT2, TNNI3, CSRP3, MYH6 and MYL2 genes. Significantly 22 are novel gene mutations. Conclusions HRM was proven to be a technique with high sensitivity and a low false positive ratio allowing a rapid, innovative and low cost genotyping of HCM. In a short return, HRM as a gene scanning technique could be a cost-effective gene-based diagnosis for an accurate HCM genetic diagnosis and hopefully providing new insights into genotype/phenotype correlations.

  1. High risk for obstructive sleep apnea in patients with acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Carla Renata Silva Andrechuk

    2015-10-01

    Full Text Available Objectives: to stratify the risk for obstructive sleep apnea in patients with acute myocardial infarction, treated at a public, tertiary, teaching hospital of the state of São Paulo, Brazil, and to identify related sociodemographic and clinical factors.Method: cross-sectional analytical study with 113 patients (mean age 59.57 years, 70.8% male. A specific questionnaire was used for the sociodemographic and clinical characterization and the Berlin Questionnaire for the stratification of the risk of obstructive sleep apnea syndrome.Results: the prevalence of high risk was 60.2% and the outcome of clinical worsening during hospitalization was more frequent among these patients. The factors related to high risk were body mass index over 30 kg/m2, arterial hypertension and waist circumference indicative of cardiovascular risk, while older age (60 years and over constituted a protective factor.Conclusion: considering the high prevalence of obstructive sleep apnea and its relation to clinical worsening, it is suggested that nurses should monitor, in their clinical practice, people at high risk for this syndrome, guiding control measures of modifiable factors and aiming to prevent the associated complications, including worsening of cardiovascular diseases.

  2. Computer simulation of high resolution transmission electron micrographs: theory and analysis

    International Nuclear Information System (INIS)

    Kilaas, R.

    1985-03-01

    Computer simulation of electron micrographs is an invaluable aid in their proper interpretation and in defining optimum conditions for obtaining images experimentally. Since modern instruments are capable of atomic resolution, simulation techniques employing high precision are required. This thesis makes contributions to four specific areas of this field. First, the validity of a new method for simulating high resolution electron microscope images has been critically examined. Second, three different methods for computing scattering amplitudes in High Resolution Transmission Electron Microscopy (HRTEM) have been investigated as to their ability to include upper Laue layer (ULL) interaction. Third, a new method for computing scattering amplitudes in high resolution transmission electron microscopy has been examined. Fourth, the effect of a surface layer of amorphous silicon dioxide on images of crystalline silicon has been investigated for a range of crystal thicknesses varying from zero to 2 1/2 times that of the surface layer

  3. Development and use of a new Tc-99m myocardial perfusion agent - DMPE

    International Nuclear Information System (INIS)

    Sodd, V.J.; Nishiyama, H.; Grossman, L.W.

    1982-01-01

    Thallium-201 is used routinely in nuclear medicine as a myocardial imaging agent. Because of its high cost and inferior scintigraphic and dosimetric properties as compared to Tc-99m, efforts to develop a Tc-99m myocardial imaging agent to replace Tl-201 have been underway. The development, dosimetry, toxicity and pre-clinical investigations in dogs of a new and promising Tc-99m myocardial imaging agent, Tc-DMPE, are described

  4. Pre-hospital ticagrelor in ST-segment elevation myocardial infarction in the French ATLANTIC population

    DEFF Research Database (Denmark)

    Cayla, Guillaume; Lapostolle, Frederic; Ecollan, Patrick

    2017-01-01

    BACKGROUND: ATLANTIC was a randomized study comparing pre- and in-hospital treatment with a ticagrelor loading dose (LD) in ongoing ST-segment elevation myocardial infarction (STEMI). We sought to compare patient characteristics and clinical outcomes in France with other countries participating...... in ATLANTIC. METHODS: The population comprised 1862 patients, 660 (35.4%) from France and 1202 from 12 other countries. The main endpoints were reperfusion (≥70% ST-segment elevation resolution) and TIMI flow grade 3 before (co-primary endpoints) and after percutaneous coronary intervention (PCI). Other...... endpoints included a composite ischaemic endpoint (death/myocardial infarction/stroke/urgent revascularization/definite stent thrombosis) and bleeding events at 30days. RESULTS: In France, median times from first LD to angiography and between first and second LDs were 49 and 35min, respectively, and were...

  5. The development of high resolution silicon x-ray microcalorimeters

    Science.gov (United States)

    Porter, F. S.; Kelley, R. L.; Kilbourne, C. A.

    2005-12-01

    Recently we have produced x-ray microcalorimeters with resolving powers approaching 2000 at 5.9 keV using a spare XRS microcalorimeter array. We attached 400 um square, 8 um thick HgTe absorbers using a variety of attachment methods to an XRS array and ran the detector array at temperatures between 40 and 60 mK. The best results were for absorbers attached using the standard XRS absorber-pixel thermal isolation scheme utilizing SU8 polymer tubes. In this scenario we achieved a resolution of 3.2 eV FWHM at 5.9 keV. Substituting a silicon spacer for the SU8 tubes also yielded sub-4eV results. In contrast, absorbers attached directly to the thermistor produced significant position dependence and thus degraded resolution. Finally, we tested standard 640um-square XRS detectors at reduced bias power at 50mK and achieved a resolution of 3.7eV, a 50% improvement over the XRS flight instrument. Implanted silicon microcalorimeters are a mature flight-qualified technology that still has a substantial phase space for future development. We will discuss these new high resolution results, the various absorber attachment schemes, planned future improvements, and, finally, their relevance to future high resolution x-ray spectrometers including Constellation-X.

  6. High resolution muon computed tomography at neutrino beam facilities

    International Nuclear Information System (INIS)

    Suerfu, B.; Tully, C.G.

    2016-01-01

    X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pion decay pipe at a neutrino beam facility and what can be achieved for momentum resolution in a muon spectrometer. Such an imaging system can be applied in archaeology, art history, engineering, material identification and whenever there is a need to image inside a transportable object constructed of dense materials

  7. Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes

    International Nuclear Information System (INIS)

    Yang Yongfeng; Dokhale, Purushottam A; Silverman, Robert W; Shah, Kanai S; McClish, Mickel A; Farrell, Richard; Entine, Gerald; Cherry, Simon R

    2006-01-01

    We explore dual-ended read out of LSO arrays with two position sensitive avalanche photodiodes (PSAPDs) as a high resolution, high efficiency depth-encoding detector for PET applications. Flood histograms, energy resolution and depth of interaction (DOI) resolution were measured for unpolished LSO arrays with individual crystal sizes of 1.0, 1.3 and 1.5 mm, and for a polished LSO array with 1.3 mm pixels. The thickness of the crystal arrays was 20 mm. Good flood histograms were obtained for all four arrays, and crystals in all four arrays can be clearly resolved. Although the amplitude of each PSAPD signal decreases as the interaction depth moves further from the PSAPD, the sum of the two PSAPD signals is essentially constant with irradiation depth for all four arrays. The energy resolutions were similar for all four arrays, ranging from 14.7% to 15.4%. A DOI resolution of 3-4 mm (including the width of the irradiation band which is ∼2 mm) was obtained for all the unpolished arrays. The best DOI resolution was achieved with the unpolished 1 mm array (average 3.5 mm). The DOI resolution for the 1.3 mm and 1.5 mm unpolished arrays was 3.7 and 4.0 mm respectively. For the polished array, the DOI resolution was only 16.5 mm. Summing the DOI profiles across all crystals for the 1 mm array only degraded the DOI resolution from 3.5 mm to 3.9 mm, indicating that it may not be necessary to calibrate the DOI response separately for each crystal within an array. The DOI response of individual crystals in the array confirms this finding. These results provide a detailed characterization of the DOI response of these PSAPD-based PET detectors which will be important in the design and calibration of a PET scanner making use of this detector approach

  8. A high resolution x-ray fluorescence spectrometer for near edge absorption studies

    International Nuclear Information System (INIS)

    Stojanoff, V.; Hamalainen, K.; Siddons, D.P.; Hastings, J.B.; Berman, L.E.; Cramer, S.; Smith, G.

    1991-01-01

    A high resolution fluorescence spectrometer using a Johann geometry in a back scattering arrangement was developed. The spectrometer, with a resolution of 0.3 eV at 6.5 keV, combined with an incident beam, with a resolution of 0.7 eV, form the basis of a high resolution instrument for measuring x-ray absorption spectra. The advantages of the instrument are illustrated with the near edge absorption spectrum of dysprosium nitrate. 10 refs., 4 figs

  9. High Frequency High Spectral Resolution Focal Plane Arrays for AtLAST

    Science.gov (United States)

    Baryshev, Andrey

    2018-01-01

    Large collecting area single dish telescope such as ATLAST will be especially effective for medium (R 1000) and high (R 50000) spectral resolution observations. Large focal plane array is a natural solution to increase mapping speed. For medium resolution direct detectors with filter banks (KIDs) and or heterodyne technology can be employed. We will analyze performance limits of comparable KID and SIS focal plane array taking into account quantum limit and high background condition of terrestrial observing site. For large heterodyne focal plane arrays, a high current density AlN junctions open possibility of large instantaneous bandwidth >40%. This and possible multi frequency band FPSs presents a practical challenge for spatial sampling and scanning strategies. We will discuss phase array feeds as a possible solution, including a modular back-end system, which can be shared between KID and SIS based FPA. Finally we will discuss achievable sensitivities and pixel co unts for a high frequency (>500 GHz) FPAs and address main technical challenges: LO distribution, wire counts, bias line multiplexing, and monolithic vs. discrete mixer component integration.

  10. Clinical usefulness of technetium-99m pyrophosphate and Tl-201 myocardial imaging for the estimation of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Akio; Sato, Akihiko; Miyakoda, Hiroyuki; Watanabe, Toshiya; Itatsu, Hidetaka; Ueda, Osamu; Sakurai, Kuniteru; Kawai, Naoki; Sotobata, Iwao

    1985-04-01

    A correlative study was performed between the infarct size estimated by either technetium-99 pyrophosphate (Tc-PYP) or Tl-201 myocardial imaging, and the cumulative total creatinine phosphokinase activity (..sigma..CPK) or left ventricular ejection fraction (LVEF) in 40 patients with acute myocardial infarction. Tc-PYP infarct area (TcIA) and mean Tl-201 uptake ratio (MUR) were calculated as indices of myocardial infarct size. LVEF was evaluated by first pass method using Tc-PYP in the acute phase of myocardial infraction. In 23 patients with anterior myocardial infarction, a significant correlation was shown between either TcIA or anterior-wall MUR and ..sigma..CPK (r=0.81 and r=-0.69, respectively) and also between either TcIA or anterior-wall MUR and LVEF (r=-0.84 and r=0.80, respectively). In 17 patients with inferior myocardial infarction without additional involvement of right ventricular wall, inferior-wall MUR correlated with ..sigma..CPK (r=-0.74). No statically significant correlation was shown between TcIA and ..sigma..CPK, and also between either TcIA or inferior-wall MUR and LVEF. In conclusion, the infarct size estimated with Tc-PYP or Tl-201 myocardial imaging could be a useful clinical indicator of the severity of acute myocardial infarction especially in anterior wall. (author).

  11. A new omni-directional multi-camera system for high resolution surveillance

    Science.gov (United States)

    Cogal, Omer; Akin, Abdulkadir; Seyid, Kerem; Popovic, Vladan; Schmid, Alexandre; Ott, Beat; Wellig, Peter; Leblebici, Yusuf

    2014-05-01

    Omni-directional high resolution surveillance has a wide application range in defense and security fields. Early systems used for this purpose are based on parabolic mirror or fisheye lens where distortion due to the nature of the optical elements cannot be avoided. Moreover, in such systems, the image resolution is limited to a single image sensor's image resolution. Recently, the Panoptic camera approach that mimics the eyes of flying insects using multiple imagers has been presented. This approach features a novel solution for constructing a spherically arranged wide FOV plenoptic imaging system where the omni-directional image quality is limited by low-end sensors. In this paper, an overview of current Panoptic camera designs is provided. New results for a very-high resolution visible spectrum imaging and recording system inspired from the Panoptic approach are presented. The GigaEye-1 system, with 44 single cameras and 22 FPGAs, is capable of recording omni-directional video in a 360°×100° FOV at 9.5 fps with a resolution over (17,700×4,650) pixels (82.3MP). Real-time video capturing capability is also verified at 30 fps for a resolution over (9,000×2,400) pixels (21.6MP). The next generation system with significantly higher resolution and real-time processing capacity, called GigaEye-2, is currently under development. The important capacity of GigaEye-1 opens the door to various post-processing techniques in surveillance domain such as large perimeter object tracking, very-high resolution depth map estimation and high dynamicrange imaging which are beyond standard stitching and panorama generation methods.

  12. EMODnet High Resolution Seabed Mapping - further developing a high resolution digital bathymetry for European seas

    Science.gov (United States)

    Schaap, D.; Schmitt, T.

    2017-12-01

    Access to marine data is a key issue for the EU Marine Strategy Framework Directive and the EU Marine Knowledge 2020 agenda and includes the European Marine Observation and Data Network (EMODnet) initiative. EMODnet aims at assembling European marine data, data products and metadata from diverse sources in a uniform way. The EMODnet Bathymetry project has developed Digital Terrain Models (DTM) for the European seas. These have been produced from survey and aggregated data sets that are indexed with metadata by adopting the SeaDataNet Catalogue services. SeaDataNet is a network of major oceanographic data centres around the European seas that manage, operate and further develop a pan-European infrastructure for marine and ocean data management. The latest EMODnet Bathymetry DTM release has a grid resolution of 1/8 arcminute and covers all European sea regions. Use has been made of circa 7800 gathered survey datasets and composite DTMs. Catalogues and the EMODnet DTM are published at the dedicated EMODnet Bathymetry portal including a versatile DTM viewing and downloading service. End December 2016 the Bathymetry project has been succeeded by EMODnet High Resolution Seabed Mapping (HRSM). This continues gathering of bathymetric in-situ data sets with extra efforts for near coastal waters and coastal zones. In addition Satellite Derived Bathymetry data are included to fill gaps in coverage of the coastal zones. The extra data and composite DTMs will increase the coverage of the European seas and its coastlines, and provide input for producing an EMODnet DTM with a common resolution of 1/16 arc minutes. The Bathymetry Viewing and Download service will be upgraded to provide a multi-resolution map and including 3D viewing. The higher resolution DTMs will also be used to determine best-estimates of the European coastline for a range of tidal levels (HAT, MHW, MSL, Chart Datum, LAT), thereby making use of a tidal model for Europe. Extra challenges will be `moving to the

  13. Obesity, Inflammation and Acute Myocardial Infarction - Expression of leptin, IL-6 and high sensitivity-CRP in Chennai based population

    Directory of Open Access Journals (Sweden)

    Rajendran Karthick

    2012-08-01

    Full Text Available Abstract Background Obesity, characterised by increased fat mass and is currently regarded as a pro-inflammatory state and often associated with increased risk of cardiovascular diseases (CVD including Myocardial infarction. There is an upregulation of inflammatory markers such as interleukin-6, interleukin-6 receptor and acute phase protein CRP in Acute Myocardial Infarction (AMI patients but the exact mechanism linking obesity and inflammation is not known. It is of our interest to investigate if serum leptin (ob gene product is associated with AMI and correlated with inflammatory proteins namely Interleukin-6 (IL-6 and high sensitivity - C reactive protein (hs-CRP. Results Serum leptin levels were significantly higher in AMI patients when compared to Non-CVD controls. IL-6 and hs-CRP were also elevated in the AMI group and leptin correlated positively with IL-6 and hs-CRP. Incidentally this is the first report from Chennai based population, India. Conclusions The strong correlation between serum levels of leptin and IL-6 implicates an involvement of leptin in the upregulation of inflammatory cytokines during AMI. We hypothesise that the increase in values of IL-6, hs-CRP and their correlation to leptin in AMI patients could be due to participation of leptin in the signaling cascade after myocardial ischemia.

  14. Obesity, Inflammation and Acute Myocardial Infarction - Expression of leptin, IL-6 and high sensitivity-CRP in Chennai based population.

    Science.gov (United States)

    Rajendran, Karthick; Devarajan, Nalini; Ganesan, Manohar; Ragunathan, Malathi

    2012-08-14

    Obesity, characterised by increased fat mass and is currently regarded as a pro-inflammatory state and often associated with increased risk of cardiovascular diseases (CVD) including Myocardial infarction. There is an upregulation of inflammatory markers such as interleukin-6, interleukin-6 receptor and acute phase protein CRP in Acute Myocardial Infarction (AMI) patients but the exact mechanism linking obesity and inflammation is not known. It is of our interest to investigate if serum leptin (ob gene product) is associated with AMI and correlated with inflammatory proteins namely Interleukin-6 (IL-6) and high sensitivity - C reactive protein (hs-CRP). Serum leptin levels were significantly higher in AMI patients when compared to Non-CVD controls. IL-6 and hs-CRP were also elevated in the AMI group and leptin correlated positively with IL-6 and hs-CRP. Incidentally this is the first report from Chennai based population, India. The strong correlation between serum levels of leptin and IL-6 implicates an involvement of leptin in the upregulation of inflammatory cytokines during AMI. We hypothesise that the increase in values of IL-6, hs-CRP and their correlation to leptin in AMI patients could be due to participation of leptin in the signaling cascade after myocardial ischemia.

  15. High resolution microphotonic needle for endoscopic imaging (Conference Presentation)

    Science.gov (United States)

    Tadayon, Mohammad Amin; Mohanty, Aseema; Roberts, Samantha P.; Barbosa, Felippe; Lipson, Michal

    2017-02-01

    GRIN (Graded index) lens have revolutionized micro endoscopy enabling deep tissue imaging with high resolution. The challenges of traditional GRIN lenses are their large size (when compared with the field of view) and their limited resolution. This is because of the relatively weak NA in standard graded index lenses. Here we introduce a novel micro-needle platform for endoscopy with much higher resolution than traditional GRIN lenses and a FOV that corresponds to the whole cross section of the needle. The platform is based on polymeric (SU-8) waveguide integrated with a microlens micro fabricated on a silicon substrate using a unique molding process. Due to the high index of refraction of the material the NA of the needle is much higher than traditional GRIN lenses. We tested the probe in a fluorescent dye solution (19.6 µM Alexa Flour 647 solution) and measured a numerical aperture of 0.25, focal length of about 175 µm and minimal spot size of about 1.6 µm. We show that the platform can image a sample with the field of view corresponding to the cross sectional area of the waveguide (80x100 µm2). The waveguide size can in principle be modified to vary size of the imaging field of view. This demonstration, combined with our previous work demonstrating our ability to implant the high NA needle in a live animal, shows that the proposed system can be used for deep tissue imaging with very high resolution and high field of view.

  16. Imaging collagen type I fibrillogenesis with high spatiotemporal resolution

    International Nuclear Information System (INIS)

    Stamov, Dimitar R; Stock, Erik; Franz, Clemens M; Jähnke, Torsten; Haschke, Heiko

    2015-01-01

    Fibrillar collagens, such as collagen type I, belong to the most abundant extracellular matrix proteins and they have received much attention over the last five decades due to their large interactome, complex hierarchical structure and high mechanical stability. Nevertheless, the collagen self-assembly process is still incompletely understood. Determining the real-time kinetics of collagen type I formation is therefore pivotal for better understanding of collagen type I structure and function, but visualising the dynamic self-assembly process of collagen I on the molecular scale requires imaging techniques offering high spatiotemporal resolution. Fast and high-speed scanning atomic force microscopes (AFM) provide the means to study such processes on the timescale of seconds under near-physiological conditions. In this study we have applied fast AFM tip scanning to study the assembly kinetics of fibrillar collagen type I nanomatrices with a temporal resolution reaching eight seconds for a frame size of 500 nm. By modifying the buffer composition and pH value, the kinetics of collagen fibrillogenesis can be adjusted for optimal analysis by fast AFM scanning. We furthermore show that amplitude-modulation imaging can be successfully applied to extract additional structural information from collagen samples even at high scan rates. Fast AFM scanning with controlled amplitude modulation therefore provides a versatile platform for studying dynamic collagen self-assembly processes at high resolution. - Highlights: • Continuous non-invasive time-lapse investigation of collagen I fibrillogenesis in situ. • Imaging of collagen I self-assembly with high spatiotemporal resolution. • Application of setpoint modulation to study the hierarchical structure of collagen I. • Observing real-time formation of the D-banding pattern in collagen I

  17. Imaging collagen type I fibrillogenesis with high spatiotemporal resolution

    Energy Technology Data Exchange (ETDEWEB)

    Stamov, Dimitar R, E-mail: stamov@jpk.com [JPK Instruments AG, Bouchéstrasse 12, 12435 Berlin (Germany); Stock, Erik [JPK Instruments AG, Bouchéstrasse 12, 12435 Berlin (Germany); Franz, Clemens M [DFG-Center for Functional Nanostructures (CFN), Karlsruhe Institute of Technology (KIT), Wolfgang-Gaede-Strasse 1a, 76131 Karlsruhe (Germany); Jähnke, Torsten; Haschke, Heiko [JPK Instruments AG, Bouchéstrasse 12, 12435 Berlin (Germany)

    2015-02-15

    Fibrillar collagens, such as collagen type I, belong to the most abundant extracellular matrix proteins and they have received much attention over the last five decades due to their large interactome, complex hierarchical structure and high mechanical stability. Nevertheless, the collagen self-assembly process is still incompletely understood. Determining the real-time kinetics of collagen type I formation is therefore pivotal for better understanding of collagen type I structure and function, but visualising the dynamic self-assembly process of collagen I on the molecular scale requires imaging techniques offering high spatiotemporal resolution. Fast and high-speed scanning atomic force microscopes (AFM) provide the means to study such processes on the timescale of seconds under near-physiological conditions. In this study we have applied fast AFM tip scanning to study the assembly kinetics of fibrillar collagen type I nanomatrices with a temporal resolution reaching eight seconds for a frame size of 500 nm. By modifying the buffer composition and pH value, the kinetics of collagen fibrillogenesis can be adjusted for optimal analysis by fast AFM scanning. We furthermore show that amplitude-modulation imaging can be successfully applied to extract additional structural information from collagen samples even at high scan rates. Fast AFM scanning with controlled amplitude modulation therefore provides a versatile platform for studying dynamic collagen self-assembly processes at high resolution. - Highlights: • Continuous non-invasive time-lapse investigation of collagen I fibrillogenesis in situ. • Imaging of collagen I self-assembly with high spatiotemporal resolution. • Application of setpoint modulation to study the hierarchical structure of collagen I. • Observing real-time formation of the D-banding pattern in collagen I.

  18. Clinical Significance of Reverse Redistribution Phenomenon on Delayed Tc-99m Tetrofosmin Myocardial Perfusion Imaging in Patients with Acute Myocardial Infarction

    International Nuclear Information System (INIS)

    Park, Soon Ah; Kim, Dae Weung; Kim, Chang Guhn; Jeong, Jin Won; Kim, Nam Ho; Yun, Kyeong Ho

    2009-01-01

    This study was performed to investigate the clinical significance of reverse redistribution (RR) phenomenon detected on delayed Tc-99m tetrofosmin myocardial single photon emission computed tomography (SPECT) in patients with acute myocardial infarction after revascularization. A Tc-99m tetrofrosmin myocardial SPECT was performed in 67 consecutive patients after revascularization for acute myocardial infarction. Myocardial SPECT imaging was performed for early imaging at 40 min and for delayed imaging at 180 min after reinjection at myocardial stress. Regional myocardial uptakes were scored by 4-point scoring in the left ventricular wall divided into 17 segments. Reverse redistribution was defined as an increase of more than 2 point in the activity score on the delayed image. Follow-up myocardial SPECT and coronary angiography (CAG) were performed 9 months later. On myocardial SPECT performed following revascularization, RR was observed in 100 of all 319 segments (31%) and in 43 patients (64%). The abnormalities of perfusion and regional wall motion were more severe in the patients with RR compared to those without RR (p<0.05). On follow-up myocardial SPECT, the myocardial perfusion, regional wall motion, and myocardial thickness were significantly improved in the patients with RR (p<0.05) however, these changes were not significant in those without RR. There was no significant difference between the patients with RR and those without RR in the occurrence of restenosis on CAG. In patients with acute myocardial infarction, the regions showing the RR phenomenon on delayed Tc-99m tetrofosmin SPECT may reflect viable myocardium and indicate recovery of salvaged myocardium

  19. High-resolution fiber-optic microendoscopy for in situ cellular imaging.

    Science.gov (United States)

    Pierce, Mark; Yu, Dihua; Richards-Kortum, Rebecca

    2011-01-11

    Many biological and clinical studies require the longitudinal study and analysis of morphology and function with cellular level resolution. Traditionally, multiple experiments are run in parallel, with individual samples removed from the study at sequential time points for evaluation by light microscopy. Several intravital techniques have been developed, with confocal, multiphoton, and second harmonic microscopy all demonstrating their ability to be used for imaging in situ. With these systems, however, the required infrastructure is complex and expensive, involving scanning laser systems and complex light sources. Here we present a protocol for the design and assembly of a high-resolution microendoscope which can be built in a day using off-the-shelf components for under US$5,000. The platform offers flexibility in terms of image resolution, field-of-view, and operating wavelength, and we describe how these parameters can be easily modified to meet the specific needs of the end user. We and others have explored the use of the high-resolution microendoscope (HRME) in in vitro cell culture, in excised and living animal tissues, and in human tissues in vivo. Users have reported the use of several different fluorescent contrast agents, including proflavine, benzoporphyrin-derivative monoacid ring A (BPD-MA), and fluoroscein, all of which have received full, or investigational approval from the FDA for use in human subjects. High-resolution microendoscopy, in the form described here, may appeal to a wide range of researchers working in the basic and clinical sciences. The technique offers an effective and economical approach which complements traditional benchtop microscopy, by enabling the user to perform high-resolution, longitudinal imaging in situ.

  20. 1024 matrix image reconstruction: usefulness in high resolution chest CT

    International Nuclear Information System (INIS)

    Jeong, Sun Young; Chung, Myung Jin; Chong, Se Min; Sung, Yon Mi; Lee, Kyung Soo

    2006-01-01

    We tried to evaluate whether high resolution chest CT with a 1,024 matrix has a significant advantage in image quality compared to a 512 matrix. Each set of 512 and 1024 matrix high resolution chest CT scans with both 0.625 mm and 1.25 mm slice thickness were obtained from 26 patients. Seventy locations that contained twenty-four low density lesions without sharp boundary such as emphysema, and forty-six sharp linear densities such as linear fibrosis were selected; these were randomly displayed on a five mega pixel LCD monitor. All the images were masked for information concerning the matrix size and slice thickness. Two chest radiologists scored the image quality of each ar rowed lesion as follows: (1) undistinguishable, (2) poorly distinguishable, (3) fairly distinguishable, (4) well visible and (5) excellently visible. The scores were compared from the aspects of matrix size, slice thickness and the different observers by using ANOVA tests. The average and standard deviation of image quality were 3.09 (± .92) for the 0.625 mm x 512 matrix, 3.16 (± .84) for the 0.625 mm x 1024 matrix, 2.49 (± 1.02) for the 1.25 mm x 512 matrix, and 2.35 (± 1.02) for the 1.25 mm x 1024 matrix, respectively. The image quality on both matrices of the high resolution chest CT scans with a 0.625 mm slice thickness was significantly better than that on the 1.25 mm slice thickness (ρ < 0.001). However, the image quality on the 1024 matrix high resolution chest CT scans was not significantly different from that on the 512 matrix high resolution chest CT scans (ρ = 0.678). The interobserver variation between the two observers was not significant (ρ = 0.691). We think that 1024 matrix image reconstruction for high resolution chest CT may not be clinical useful

  1. Study on a high resolution positron emission tomography scanner for brain study

    International Nuclear Information System (INIS)

    Nohara, N.; Tomitani, T.; Yamamoto, M.; Murayama, H.; Tanaka, E.

    1990-01-01

    The spatial resolution of positron emission tomography (PET) scanners is usually limited by the finite size of crystals such as bismuth germanate (BGO). To attain high resolution as well as high sensitivity, it is essential to use a large number of small BGO crystals arranged in close-packing on circular rings. In developing high resolution PET scanners, however, there are two physical factors limiting the spatial resolution. One is the finite range of positrons before annihilation and the other the deviation from 180 degrees of annihilation photons. The effect of the factors on the spatial resolution has been evaluated for positron-emitting sources as a function of detector ring radius. A high resolution PET scanner has been developed for brain study, aiming to have spatial resolutions as high as less than 4-mm FWHM in tomographic plane and less than 6-mm FWHM in axial direction at the detector ring center. For the goal of the high resolutions a multi-segment type of photomultiplier tubes has been specially designed and developed, which allows one tube to be directly coupled by four BGO crystals. The scanner consists of five detector rings of 47-cm in diameter, using all 1200 BGO crystals each measuring 5 mm x 12 mm x 30 mm. The scanner provides simultaneous 9 images by combination of in-plane and cross-plane, offering a 24-cm dia. x7.4-cm field-of-view. Physical performance of the scanner was investigated. At the ring center, the spatial resolution in the tomographic plane was measured to be 3.5-mm FWHM. The axial resolution was measured to be 5.7-mm FWHM for in-plane and 5.3-mm FWHM for cross-plane. Sensitivity for a 20-cm dia. uniform source was measured to be 9.5 kcps/μCi/ml for in-plane and 15.3 kcps/μCi/ml for cross-plane. (J.P.N.)

  2. Beam-transport system for high-resolution heavy-ion spectroscopy

    International Nuclear Information System (INIS)

    Roussel, P.; Kashy, E.

    1980-01-01

    A method is given to adjust a beam-transport system to the requirements of high-energy resolution heavy-ion spectroscopy. The results of a test experiment performed on a MP tandem with a 12 C beam are shown. A drastic improvement in energy resolution is obtained for a kinematical factor K=1/p dp/dtheta=0.12 [fr

  3. Influence of high energy phosphate metabolism in postischemic myocardial dysfunction using magnetic resonance spectroscopy; Influencia dos fosfatos de alta energia na funcao ventricular em pacientes com infarto do miocardio avaliada pela resonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Kalil Filho, Roberto [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina. Hospital das Clinicas

    1998-05-01

    The recovery of left ventricular function after reperfusion is delayed in general by several hours, days or weeks and this phenomenon is known as myocardial stunning. One of the theories to explain the pathogenesis of this postischemic myocardial dysfunction is the production of not enough energy by mitochondria, leading to decreased adenosine-triphosphate (ATP) levels. We evaluated the influence of high energy phosphate metabolism in postischemic myocardial dysfunction, using magnetic resonance spectroscopy in patients with acute anterior wall myocardial infarction, successfully reperfused, within the first six hours from the onset of the symptoms. Twenty-nine patients were studied in the acute phase (on average four days after the onset of myocardial infarction) and 21 repeated the examination in the follow-up phase (average 39 days). Regional left ventricular function was evaluated by cine-resonance and high energy phosphate metabolism by phosphorus-31 spectroscopy, using the phosphocreatine {beta} ATP (P Cr/{beta}ATP) ratio. The existence of myocardial stunning was suggested by the improvement of the related regional contractility during the follow-up. The contractility improved in the septal wall from 2.46{+-} 0.68 to 1.54 {+-} 0.78 (p<0.001), in the anteroseptal wall from 2.0 {+-} 0.89 to 1.40 {+-} 0.75 (p<0.001) and in the anterior wall from 2.37 {+-} 0.71 to 1.41 {+-} 0.59 (p<0.001). The P Cr/{beta}ATP ratio did not change from acute to follow-up phase (1.51 {+-} 0.17 vs. 1.53 {+-} 0.17; p = 0.6). This study suggests that decreased high energy phosphate metabolism after reperfusion does not have an important role in the genesis of the myocardial stunning in patients with acute anterior wall myocardial infarction. (author) 25 refs., 9 figs., 1 tab.

  4. Workshop on high-resolution, large-acceptance spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Zeidman, B. (ed.)

    1981-01-01

    The purpose of the Workshop on High-Resolution, Large-Acceptance Spectrometers was to provide a means for exchange of information among those actively engaged in the design and construction of these new spectrometers. Thirty-seven papers were prepared for the data base.

  5. Very high-resolution regional climate simulations over Scandinavia-present climate

    DEFF Research Database (Denmark)

    Christensen, Ole B.; Christensen, Jens H.; Machenhauer, Bennert

    1998-01-01

    realistically simulated. It is found in particular that in mountainous regions the high-resolution simulation shows improvements in the simulation of hydrologically relevant fields such as runoff and snow cover. Also, the distribution of precipitation on different intensity classes is most realistically...... on a high-density station network for the Scandinavian countries compiled for the present study. The simulated runoff is compared with observed data from Sweden extracted from a Swedish climatological atlas. These runoff data indicate that the precipitation analyses are underestimating the true...... simulated in the high-resolution simulation. It does, however, inherit certain large-scale systematic errors from the driving GCM. In many cases these errors increase with increasing resolution. Model verification of near-surface temperature and precipitation is made using a new gridded climatology based...

  6. Preoperative prediction of reversible myocardial asynergy by postexercise radionuclide ventriculography

    International Nuclear Information System (INIS)

    Rozanski, A.; Berman, D.; Gray, R.; Diamond, G.; Raymond, M.; Prause, J.; Maddahi, J.; Swan, H.J.; Matloff, J.

    1982-01-01

    Myocardial asynergy is sometimes reversed by coronary bypass, and a noninvasive method of predicting which assess are reversible would be desirable. To assess whether changes in myocardial wall motion observed immediately after exercise can differentiate reversible from nonreversible myocardial asynergy, we evaluated 53 patients by radionuclide ventriculography before and after exercise and again at rest after coronary bypass surgery. Preoperative improvement in wall motion immediately after exercise was highly predictive of the surgical outcome (average chance-corrected agreement, 91 per cent). At surgery the asynergic segments that had improved after exercise were free of grossly apparent epicardial scarring. The accuracy of these predictions for postoperative improvement was significantly greater (P less than 0.01) than that of analysis of Q waves on resting electrocardiography (average chance-corrected agreement, 40 per cent). In contrast, preoperative changes in left ventricular ejection fraction after exercise were not predictive of postoperative resting ejection fraction. We conclude that postexercise radionuclide ventriculography can be used to identify reversible resting myocardial asynergy. This test should prove effective in predicting which patients with myocardial asynergy are most likely to benefit from aortocoronary revascularization

  7. Quantitative assessment of 201TlCl myocardial SPECT

    International Nuclear Information System (INIS)

    Uehara, Toshiisa

    1987-01-01

    Clinical evaluation of the quantitative analysis of Tl-201 myocardial tomography by SPECT (Single Photon Emission Computed Tomography) was performed in comparison with visual evaluation. The method of quantitative analysis has been already reported in our previous paper. In this study, the program of re-standardization in the case of lateral myocardial infarction was added. This program was useful mainly for the evaluation of lesions in the left circumflex coronary artery. Regarding the degree of diagnostic accuracy of myocardial infarction in general, quantitative evaluation of myocardial SPECT images was highest followed by visual evaluation of myocardial SPECT images, and visual evaluation of myocardial planar images. However, in the case of anterior myocardial infarction, visual evaluation of myocardial SPECT images has almost the same detectability as quantitative evaluation of myocardial SPECT images. In the case of infero-posterior myocardial infarction, quantitative evaluation was superior to visual evaluation. As for specificity, quantitative evaluation of SPECT images was slightly inferior to visual evaluation of SPECT images. An infarction map was made by quantitative analysis and this enabled us to determine the infarction site, extent and degree according to easily recognizable patterns. As a result, the responsible coronary artery lesion could be inferred correctly and the calculated infarction score could be correlated with the residual left ventricular function after myocardial infarction. (author)

  8. [Prognosis significance of blood homocysteine after myocardial infarction].

    Science.gov (United States)

    Reis, R P; Azinheira, J; Reis, H P; Bordalo e Sá, A; Tavares, J; Adão, M; Santos, A L; Pina, J E; Correia, J M; Luís, A S

    2000-05-01

    Homocysteinemia is an independent risk factor of coronary artery disease and of myocardial infarction. In the present study we intend to relate fasting homocystein levels to prognosis after a myocardial infarction. From 1990 to 1992, we studied fasting homocysteinemia levels on a group of 112 patients aged under 56 years that had suffered a myocardial infarction between 3 and 12 months before. We obtained, the patients names, addresses, phone numbers and physicians' name. Seven years later (on average) we collected data regarding the patients evolution, consulting medical records, their physicians or by personal contact. We evaluated complications, namely mortality, vascular morbidity, such as unstable angina, re-infarction, stroke, and the need for invasive procedures (catheterism, PTCA, CABG). According to previous studies of the group, we used a cut-point of 10.10 mumol/L to define patients with normal or pathological levels of homocysteinemia. We excluded all patients that took vitamin B supplements, co-factors of HC metabolism, during this follow-up. We were able to obtain data on 110 patients. Patients with normal HC levels (n = 62) presented less global complications (26 versus 72%, p homocystein levels (n = 48), those with higher homocystein levels presented a higher degree of complications. In this population with myocardial infarction under 56 years of age, a high homocysteinemia level is an important prognostic factor. This study suggests that we can improve the prognosis and decrease the complications after myocardial infarction by lowering elevated homocystein levels.

  9. Acute myocardial infarction mortality in Cuba, 1999-2008.

    Science.gov (United States)

    Armas, Nurys B; Ortega, Yanela Y; de la Noval, Reinaldo; Suárez, Ramón; Llerena, Lorenzo; Dueñas, Alfredo F

    2012-10-01

    Acute myocardial infarction is one of the leading causes of death in the world. This is also true in Cuba, where no national-level epidemiologic studies of related mortality have been published in recent years. Describe acute myocardial infarction mortality in Cuba from 1999 through 2008. A descriptive study was conducted of persons aged ≥25 years with a diagnosis of acute myocardial infarction from 1999 through 2008. Data were obtained from the Ministry of Public Health's National Statistics Division database for variables: age; sex; site (out of hospital, in hospital or in hospital emergency room) and location (jurisdiction) of death. Proportions, age- and sex-specific rates and age-standardized overall rates per 100,000 population were calculated and compared over time, using the two five-year time frames within the study period. A total of 145,808 persons who had suffered acute myocardial infarction were recorded, 75,512 of whom died, for a case-fatality rate of 51.8% (55.1% in 1999-2003 and 49.7% in 2004-2008). In the first five-year period, mortality was 98.9 per 100,000 population, falling to 81.8 per 100,000 in the second; most affected were people aged ≥75 years and men. Of Cuba's 14 provinces and special municipality, Havana, Havana City and Camagüey provinces, and the Isle of Youth Special Municipality showed the highest mortality; Holguín, Ciego de Ávila and Granma provinces the lowest. Out-of-hospital deaths accounted for the greatest proportion of deaths in both five-year periods (54.8% and 59.2% in 1999-2003 and 2004-2008, respectively). Although risk of death from acute myocardial infarction decreased through the study period, it remains a major health problem in Cuba. A national acute myocardial infarction case registry is needed. Also required is further research to help elucidate possible causes of Cuba's high acute myocardial infarction mortality: cardiovascular risk studies, studies of out-of-hospital mortality and quality of care

  10. Digital signal processors for cryogenic high-resolution x-ray detector readout

    International Nuclear Information System (INIS)

    Friedrich, Stephan; Drury, Owen B.; Bechstein, Sylke; Hennig, Wolfgang; Momayezi, Michael

    2003-01-01

    We are developing fast digital signal processors (DSPs) to read out superconducting high-resolution X-ray detectors with on-line pulse processing. For superconducting tunnel junction (STJ) detector read-out, the DSPs offer online filtering, rise time discrimination and pile-up rejection. Compared to analog pulse processing, DSP readout somewhat degrades the detector resolution, but improves the spectral purity of the detector response. We discuss DSP performance with our 9-channel STJ array for synchrotron-based high-resolution X-ray spectroscopy. (author)

  11. High spatial resolution CT image reconstruction using parallel computing

    International Nuclear Information System (INIS)

    Yin Yin; Liu Li; Sun Gongxing

    2003-01-01

    Using the PC cluster system with 16 dual CPU nodes, we accelerate the FBP and OR-OSEM reconstruction of high spatial resolution image (2048 x 2048). Based on the number of projections, we rewrite the reconstruction algorithms into parallel format and dispatch the tasks to each CPU. By parallel computing, the speedup factor is roughly equal to the number of CPUs, which can be up to about 25 times when 25 CPUs used. This technique is very suitable for real-time high spatial resolution CT image reconstruction. (authors)

  12. High resolution and simultaneous monitoring of airborne radionuclides

    International Nuclear Information System (INIS)

    Abe, T.; Yamaguchi, Y.; Muguntha Manikandan, N.; Komura, K.

    2005-01-01

    By using 11 extremely low background Ge detectors at Ogoya Underground Laboratory, it became possible to investigate temporal variations of airborne 212 Pb (T 1/2 =10.6 h) along with 210 Pb and 7 Be with order of magnitude higher time resolution. Then, we have measured airborne nuclides at three monitoring points, (1) roof of our laboratory (LLRL; 40 m ASL), (2) Shinshiku Plateau (640 m ASL) located about 8 km from LLRL as a comparison of vertical distribution, and (3) Hegura Island (10 m ASL) at about 50 km from Wajima located north of Noto Peninsula facing on the Sea of Japan (about 180 km to the north-northeast of LLRL), to investigate influence of Asian continent. Airborne nuclides were collected by high volume air samplers at intervals of a few hours at either two or three points simultaneously. In the same manner, high resolution monitoring was carried out also at the time of passage of typhoon and cold front. In this study, we observed drastic temporal variations of airborne radionuclides and correlations of multiple monitoring points. The results indicate that high resolution and simultaneous monitoring is very useful to understand dynamic state of variations of airborne nuclides due to short and long-term air-mass movement. (author)

  13. High-resolution multimodal clinical multiphoton tomography of skin

    Science.gov (United States)

    König, Karsten

    2011-03-01

    This review focuses on multimodal multiphoton tomography based on near infrared femtosecond lasers. Clinical multiphoton tomographs for 3D high-resolution in vivo imaging have been placed into the market several years ago. The second generation of this Prism-Award winning High-Tech skin imaging tool (MPTflex) was introduced in 2010. The same year, the world's first clinical CARS studies have been performed with a hybrid multimodal multiphoton tomograph. In particular, non-fluorescent lipids and water as well as mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen has been imaged with submicron resolution in patients suffering from psoriasis. Further multimodal approaches include the combination of multiphoton tomographs with low-resolution wide-field systems such as ultrasound, optoacoustical, OCT, and dermoscopy systems. Multiphoton tomographs are currently employed in Australia, Japan, the US, and in several European countries for early diagnosis of skin cancer, optimization of treatment strategies, and cosmetic research including long-term testing of sunscreen nanoparticles as well as anti-aging products.

  14. Integrated High Resolution Monitoring of Mediterranean vegetation

    Science.gov (United States)

    Cesaraccio, Carla; Piga, Alessandra; Ventura, Andrea; Arca, Angelo; Duce, Pierpaolo; Mereu, Simone

    2017-04-01

    The study of the vegetation features in a complex and highly vulnerable ecosystems, such as Mediterranean maquis, leads to the need of using continuous monitoring systems at high spatial and temporal resolution, for a better interpretation of the mechanisms of phenological and eco-physiological processes. Near-surface remote sensing techniques are used to quantify, at high temporal resolution, and with a certain degree of spatial integration, the seasonal variations of the surface optical and radiometric properties. In recent decades, the design and implementation of global monitoring networks involved the use of non-destructive and/or cheaper approaches such as (i) continuous surface fluxes measurement stations, (ii) phenological observation networks, and (iii) measurement of temporal and spatial variations of the vegetation spectral properties. In this work preliminary results from the ECO-SCALE (Integrated High Resolution Monitoring of Mediterranean vegetation) project are reported. The project was manly aimed to develop an integrated system for environmental monitoring based on digital photography, hyperspectral radiometry , and micrometeorological techniques during three years of experimentation (2013-2016) in a Mediterranean site of Italy (Capo Caccia, Alghero). The main results concerned the analysis of chromatic coordinates indices from digital images, to characterized the phenological patterns for typical shrubland species, determining start and duration of the growing season, and the physiological status in relation to different environmental drought conditions; then the seasonal patterns of canopy phenology, was compared to NEE (Net Ecosystem Exchange) patterns, showing similarities. However, maximum values of NEE and ER (Ecosystem respiration), and short term variation, seemed mainly tuned by inter annual pattern of meteorological variables, in particular of temperature recorded in the months preceding the vegetation green-up. Finally, green signals

  15. A multi-channel high-resolution time recorder system

    International Nuclear Information System (INIS)

    Zhang Lingyun; Yang Xiaojun; Song Kezhu; Wang Yanfang

    2004-01-01

    This paper introduces a multi-channel and high-speed time recorder system, which was originally designed to work in the experiments of quantum cryptography research. The novelty of the system is that all the hardware logic is performed by only one FPGA. The system can achieve several desirable features, such as simplicity, high resolution and high processing speed. (authors)

  16. Application of high resolution synchrotron micro-CT radiation in dental implant osseointegration

    DEFF Research Database (Denmark)

    Neldam, Camilla Albeck; Lauridsen, Torsten; Rack, Alexander

    2015-01-01

    The purpose of this study was to describe a refined method using high-resolution synchrotron radiation microtomography (SRmicro-CT) to evaluate osseointegration and peri-implant bone volume fraction after titanium dental implant insertion. SRmicro-CT is considered gold standard evaluating bone...... microarchitecture. Its high resolution, high contrast, and excellent high signal-to-noise-ratio all contribute to the highest spatial resolutions achievable today. Using SRmicro-CT at a voxel size of 5 μm in an experimental goat mandible model, the peri-implant bone volume fraction was found to quickly increase...

  17. Effect of nicorandil on the myocardial tissue perfusion and myocardial cell injury in patients with diabetes after PCI

    Directory of Open Access Journals (Sweden)

    Xue-Li Ren1

    2017-04-01

    Full Text Available Objective: To study the effect of nicorandil on the myocardial tissue perfusion and myocardial cell damage in patients with diabetes after percutaneous coronary intervention (PCI. Methods: 68 patients with coronary heart disease and type 2 diabetes mellitus who received PCI in our hospital between May 2011 and September 2015 were collected and then divided into observation group and control group (n=34 according to the single-blind randomized control method. Control group of patients received PCI alone, and the observation group of patients received nicorandil therapy after PCI. After treatment, real-time myocardial ultrasound contrast was used to evaluate the myocardial perfusion of two groups of patients; blood biochemical analyzer was used to detect the contents of peripheral blood myocardial enzyme spectrum indexes; the ELISA method was used to detect the contents of serum oxidative stress indicators; RIA method was used to detect the contents of serum apoptosis molecules. Results: After treatment, the myocardial tissue perfusion parameters plateau peak intensity (A, slope rate of curve (β and myocardial blood flow (A×β levels of observation group were significantly higher than those of control group (P<0.05; peripheral blood myocardial enzyme spectrum indexes creatine kinase (CK, lactate dehydrogenase (LDH, troponin I (cTnI and glutamic oxalacetic transaminase (GOT contents of observation group were significantly lower than those of control group (P<0.05; serum vitamin E (VitE and vitamin C (VitC contents of observation group were significantly higher than those of control group while malondialdehyde (MDA, advanced oxidation protein products (AOPPs, soluble apoptosis-associated factor (sFas and soluble apoptosis-associated factor ligand (sFasL contents were lower than those of control group (P<0.05. Conclusion: Adjuvant nicorandil therapy can improve the myocardial perfusion and reduce the myocardial cell injury in patients with coronary

  18. An angle encoder for super-high resolution and super-high accuracy using SelfA

    Science.gov (United States)

    Watanabe, Tsukasa; Kon, Masahito; Nabeshima, Nobuo; Taniguchi, Kayoko

    2014-06-01

    Angular measurement technology at high resolution for applications such as in hard disk drive manufacturing machines, precision measurement equipment and aspherical process machines requires a rotary encoder with high accuracy, high resolution and high response speed. However, a rotary encoder has angular deviation factors during operation due to scale error or installation error. It has been assumed to be impossible to achieve accuracy below 0.1″ in angular measurement or control after the installation onto the rotating axis. Self-calibration (Lu and Trumper 2007 CIRP Ann. 56 499; Kim et al 2011 Proc. MacroScale; Probst 2008 Meas. Sci. Technol. 19 015101; Probst et al Meas. Sci. Technol. 9 1059; Tadashi and Makoto 1993 J. Robot. Mechatronics 5 448; Ralf et al 2006 Meas. Sci. Technol. 17 2811) and cross-calibration (Probst et al 1998 Meas. Sci. Technol. 9 1059; Just et al 2009 Precis. Eng. 33 530; Burnashev 2013 Quantum Electron. 43 130) technologies for a rotary encoder have been actively discussed on the basis of the principle of circular closure. This discussion prompted the development of rotary tables which achieve reliable and high accuracy angular verification. We apply these technologies for the development of a rotary encoder not only to meet the requirement of super-high accuracy but also to meet that of super-high resolution. This paper presents the development of an encoder with 221 = 2097 152 resolutions per rotation (360°), that is, corresponding to a 0.62″ signal period, achieved by the combination of a laser rotary encoder supplied by Magnescale Co., Ltd and a self-calibratable encoder (SelfA) supplied by The National Institute of Advanced Industrial Science & Technology (AIST). In addition, this paper introduces the development of a rotary encoder to guarantee ±0.03″ accuracy at any point of the interpolated signal, with respect to the encoder at the minimum resolution of 233, that is, corresponding to a 0.0015″ signal period after

  19. Quantifying and containing the curse of high resolution coronal imaging

    Directory of Open Access Journals (Sweden)

    V. Delouille

    2008-10-01

    Full Text Available Future missions such as Solar Orbiter (SO, InterHelioprobe, or Solar Probe aim at approaching the Sun closer than ever before, with on board some high resolution imagers (HRI having a subsecond cadence and a pixel area of about (80 km2 at the Sun during perihelion. In order to guarantee their scientific success, it is necessary to evaluate if the photon counts available at these resolution and cadence will provide a sufficient signal-to-noise ratio (SNR. For example, if the inhomogeneities in the Quiet Sun emission prevail at higher resolution, one may hope to locally have more photon counts than in the case of a uniform source. It is relevant to quantify how inhomogeneous the quiet corona will be for a pixel pitch that is about 20 times smaller than in the case of SoHO/EIT, and 5 times smaller than TRACE. We perform a first step in this direction by analyzing and characterizing the spatial intermittency of Quiet Sun images thanks to a multifractal analysis. We identify the parameters that specify the scale-invariance behavior. This identification allows next to select a family of multifractal processes, namely the Compound Poisson Cascades, that can synthesize artificial images having some of the scale-invariance properties observed on the recorded images. The prevalence of self-similarity in Quiet Sun coronal images makes it relevant to study the ratio between the SNR present at SoHO/EIT images and in coarsened images. SoHO/EIT images thus play the role of "high resolution" images, whereas the "low-resolution" coarsened images are rebinned so as to simulate a smaller angular resolution and/or a larger distance to the Sun. For a fixed difference in angular resolution and in Spacecraft-Sun distance, we determine the proportion of pixels having a SNR preserved at high resolution given a particular increase in effective area. If scale-invariance continues to prevail at smaller scales, the conclusion reached with SoHO/EIT images can be transposed

  20. A High-resolution Reanalysis for the European CORDEX Region

    Science.gov (United States)

    Bentzien, Sabrina; Bollmeyer, Christoph; Crewell, Susanne; Friederichs, Petra; Hense, Andreas; Keller, Jan; Keune, Jessica; Kneifel, Stefan; Ohlwein, Christian; Pscheidt, Ieda; Redl, Stephanie; Steinke, Sandra

    2014-05-01

    A High-resolution Reanalysis for the European CORDEX Region Within the Hans-Ertel-Centre for Weather Research (HErZ), the climate monitoring branch concentrates efforts on the assessment and analysis of regional climate in Germany and Europe. In joint cooperation with DWD (German Meteorological Service), a high-resolution reanalysis system based on the COSMO model has been developed. Reanalyses gain more and more importance as a source of meteorological information for many purposes and applications. Several global reanalyses projects (e.g., ERA, MERRA, CSFR, JMA9) produce and verify these data sets to provide time series as long as possible combined with a high data quality. Due to a spatial resolution down to 50-70km and 3-hourly temporal output, they are not suitable for small scale problems (e.g., regional climate assessment, meso-scale NWP verification, input for subsequent models such as river runoff simulations). The implementation of regional reanalyses based on a limited area model along with a data assimilation scheme is able to generate reanalysis data sets with high spatio-temporal resolution. The work presented here focuses on the regional reanalysis for Europe with a domain matching the CORDEX-EURO-11 specifications, albeit at a higher spatial resolution, i.e., 0.055° (6km) instead of 0.11° (12km). The COSMO reanalysis system comprises the assimilation of observational data using the existing nudging scheme of COSMO and is complemented by a special soil moisture analysis and boundary conditions given by ERA-interim data. The reanalysis data set currently covers 6 years (2007-2012). The evaluation of the reanalyses is done using independent observations with special emphasis on precipitation and high-impact weather situations. The development and evaluation of the COSMO-based reanalysis for the CORDEX-Euro domain can be seen as a preparation for joint European activities on the development of an ensemble system of regional reanalyses for Europe.

  1. High Time Resolution Astrophysics

    CERN Document Server

    Phelan, Don; Shearer, Andrew

    2008-01-01

    High Time Resolution Astrophysics (HTRA) is an important new window to the universe and a vital tool in understanding a range of phenomena from diverse objects and radiative processes. This importance is demonstrated in this volume with the description of a number of topics in astrophysics, including quantum optics, cataclysmic variables, pulsars, X-ray binaries and stellar pulsations to name a few. Underlining this science foundation, technological developments in both instrumentation and detectors are described. These instruments and detectors combined cover a wide range of timescales and can measure fluxes, spectra and polarisation. These advances make it possible for HTRA to make a big contribution to our understanding of the Universe in the next decade.

  2. High resolution ultrasonic densitometer

    International Nuclear Information System (INIS)

    Dress, W.B.

    1983-01-01

    The velocity of torsional stress pulses in an ultrasonic waveguide of non-circular cross section is affected by the temperature and density of the surrounding medium. Measurement of the transit times of acoustic echoes from the ends of a sensor section are interpreted as level, density, and temperature of the fluid environment surrounding that section. This paper examines methods of making these measurements to obtain high resolution, temperature-corrected absolute and relative density and level determinations of the fluid. Possible applications include on-line process monitoring, a hand-held density probe for battery charge state indication, and precise inventory control for such diverse fluids as uranium salt solutions in accountability storage and gasoline in service station storage tanks

  3. Simulation study for high resolution alpha particle spectrometry with mesh type collimator

    International Nuclear Information System (INIS)

    Park, Seunghoon; Kwak, Sungwoo; Kang, Hanbyeol; Shin, Jungki; Park, Iljin

    2014-01-01

    An alpha particle spectrometry with a mesh type collimator plays a crucial role in identifying specific radionuclide in a radioactive source collected from the atmosphere or environment. The energy resolution is degraded without collimation because particles with a high angle have a longer path to travel in the air. Therefore, collision with the background increases. The collimator can cut out particles which traveling at a high angle. As a result, an energy distribution with high resolution can be obtained. Therefore, the mesh type collimator is simulated for high resolution alpha particle spectrometry. In conclusion, the collimator can improve resolution. With collimator, the collimator is a role of cutting out particles with a high angle, so, low energy tail and broadened energy distribution can be reduced. The mesh diameter is found out as an important factor to control resolution and counting efficiency. Therefore, a target particle, for example, 235 U, can be distinguished by a detector with a collimator under a mixture of various nuclides, for example: 232 U, 238 U, and 232 Th

  4. Relationship between the mismatch of 123I-BMIPP and 201Tl myocardial single-photon emission computed tomography and autonomic nervous system activity in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Yamanaka, Hiroyuki; Suzuki, Takeshi; Kishida, Hiroshi; Nagasawa, Koichi; Takano, Teruo

    2006-01-01

    The purpose of this study was to elucidate the relationship between the mismatch of thallium-201 (Tl) and iodine-123-beta-methyl-iodophenyl-pentadecanoic acid (BMIPP) myocardial single-photon emission computed tomography (SPECT) and autonomic nervous system activity in myocardial infarction (MI) patients. The subjects were 40 patients (34 males, 6 females) who underwent examinations by 123 I-BMIPP and 201 Tl myocardial SPECT imaging and 24-hour Holter monitoring within a 3-day period 3 weeks after the onset of their first MI. R-R intervals were analyzed every hour over a period of 24 hours by fast Fourier transformation (FFT). High frequency (HF) and low frequency (LF) were defined as markers of cardiac vagal activity in the former and the LF/HF ratio as sympathetic activity. Greater or more extensive decreases in the BMIPP image than that in the Tl image were defined as a positive mismatch. Patients were divided into positive and negative mismatch groups of 20 patients each. There were no significant differences between the 2 groups in age, sex, site of infarction, max CK (creatine kinase), max CK-MB, or left ventricular ejection fraction. The incidences of clinical signs suggesting residual myocardial ischemia were significantly greater in the positive than in the negative mismatch group (P 123 I-BMIPP and 201 Tl myocardial SPECT 3 weeks after a first acute myocardial infarction with uncomplicated moderate or severe heart failure and decreased heart rate variability are related to residual myocardial ischemia. A combined assessment of heart rate variability in 24 hour Holter electrocardiogram (ECG) monitoring and perfusion-metabolism mismatch in 123 I-BMIPP and 201 Tl myocardial SPECT is useful for determining residual myocardial ischemia in the follow-up of those with acute myocardial infarction. (author)

  5. Radioiodinated BMIPP for myocardial imaging - current status and future perspectives

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Kropp, J.; Franken, P.R.

    1998-01-01

    Since the 1970's both basic research applications and clinical use of radioiodinated free fatty acids has continued to be of interest in nuclear cardiology. Clinical use of iodine-123-labeled fatty acids offers a unique opportunity for direct or indirect evaluation of alterations in myocardial metabolism by single photon computed tomography (SPECT). The relationship between the negative 'mismatches' often observed between regional fatty acid uptake and perfusion tracer distribution (i.e. BMIPP defect larger than flow tracer defect) has been an important observation which can often provide information on myocardial viability. Although the widespread use of the iodine-123-labeled 15-(p-iodophenyl)-3-(R, S)-methylpentadecanoic acid (BMIPP) analogue in Japan continues to provide extensive clinical data defining indications for the use of this agent, it remains to be seen, however, if iodine-123-labeled fatty acids such as BMIPP will enter routine clinical use in other countries, since their commercial availability as approved radiopharmaceuticals will be required. In this paper further studies describing the resolution and evaluation of the metabolism and myocardial uptake and release kinetics of the 3R- and 3S-BMIPP isomers are described. Although it is beyond the scope of this brief paper to review and discuss the voluminous data which have been published concerning both clincial applications and research studies with BMIPP over the last several years, the issues associated with the broader clinical use of BMIPP and other iodine-123-labeled fatty acid agents are discussed. (orig.) [de

  6. Old tools for sophisticated diagnosis: Electrocardiography for the assessment of myocardial viability

    International Nuclear Information System (INIS)

    Margonato, A.; Chierchia, S.

    1996-01-01

    The identification of residual myocardial viability in patients with a previous myocardial infarction has important clinical implications. Various methods have been developed for the detection of viable myocardium, however most of them are expensive and available only to high-tech centers. In the attempt to obtain reliable information at a low cost, exercise-ECG has been proposed as a useful technique. The results of a series of studies show that ST segment elevation and ventricular arrhythmias elicited by exercise are reliable signs of the presence of reversible myocardial damage

  7. Low-resolution ship detection from high-altitude aerial images

    Science.gov (United States)

    Qi, Shengxiang; Wu, Jianmin; Zhou, Qing; Kang, Minyang

    2018-02-01

    Ship detection from optical images taken by high-altitude aircrafts such as unmanned long-endurance airships and unmanned aerial vehicles has broad applications in marine fishery management, ship monitoring and vessel salvage. However, the major challenge is the limited capability of information processing on unmanned high-altitude platforms. Furthermore, in order to guarantee the wide detection range, unmanned aircrafts generally cruise at high altitudes, resulting in imagery with low-resolution targets and strong clutters suffered by heavy clouds. In this paper, we propose a low-resolution ship detection method to extract ships from these high-altitude optical images. Inspired by a recent research on visual saliency detection indicating that small salient signals could be well detected by a gradient enhancement operation combined with Gaussian smoothing, we propose the facet kernel filtering to rapidly suppress cluttered backgrounds and delineate candidate target regions from the sea surface. Then, the principal component analysis (PCA) is used to compute the orientation of the target axis, followed by a simplified histogram of oriented gradient (HOG) descriptor to characterize the ship shape property. Finally, support vector machine (SVM) is applied to discriminate real targets and false alarms. Experimental results show that the proposed method actually has high efficiency in low-resolution ship detection.

  8. Gas scintillation glass GEM detector for high-resolution X-ray imaging and CT

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, T., E-mail: fujiwara-t@aist.go.jp [Research Institute for Measurement and Analytical Instrumentation, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8568 (Japan); Mitsuya, Y. [Nuclear Professional School, The University of Tokyo, Tokai, Naka, Ibaraki 319-1188 (Japan); Fushie, T. [Radiment Lab. Inc., Setagaya, Tokyo 156-0044 (Japan); Murata, K.; Kawamura, A.; Koishikawa, A. [XIT Co., Naruse, Machida, Tokyo 194-0045 (Japan); Toyokawa, H. [Research Institute for Measurement and Analytical Instrumentation, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8568 (Japan); Takahashi, H. [Institute of Engineering Innovation, School of Engineering, The University of Tokyo, Bunkyo, Tokyo 113-8654 (Japan)

    2017-04-01

    A high-spatial-resolution X-ray-imaging gaseous detector has been developed with a single high-gas-gain glass gas electron multiplier (G-GEM), scintillation gas, and optical camera. High-resolution X-ray imaging of soft elements is performed with a spatial resolution of 281 µm rms and an effective area of 100×100 mm. In addition, high-resolution X-ray 3D computed tomography (CT) is successfully demonstrated with the gaseous detector. It shows high sensitivity to low-energy X-rays, which results in high-contrast radiographs of objects containing elements with low atomic numbers. In addition, the high yield of scintillation light enables fast X-ray imaging, which is an advantage for constructing CT images with low-energy X-rays.

  9. IGF-1 Alleviates High Fat Diet-Induced Myocardial Contractile Dysfunction: Role of Insulin Signaling and Mitochondrial Function

    Science.gov (United States)

    Zhang, Yingmei; Yuan, Ming; Bradley, Katherine M.; Dong, Feng; Anversa, Piero; Ren, Jun

    2012-01-01

    Obesity is often associated with reduced plasma IGF-1 levels, oxidative stress, mitochondrial damage and cardiac dysfunction. This study was designed to evaluate the impact of IGF-1 on high fat diet-induced oxidative, myocardial, geometric and mitochondrial responses. FVB and cardiomyocyte-specific IGF-1 overexpression transgenic mice were fed a low (10%) or high fat (45%) diet to induce obesity. High fat diet feeding led to glucose intolerance, elevated plasma levels of leptin, interleukin-6, insulin and triglyceride as well as reduced circulating IGF-1 levels. Echocardiography revealed reduced fractional shortening, increased end systolic and diastolic diameter, increased wall thickness, and cardiac hypertrophy in high fat-fed FVB mice. High fat diet promoted ROS generation, apoptosis, protein and mitochondrial damage, reduced ATP content, cardiomyocyte cross-sectional area, contractile and intracellular Ca2+ dysregulation, including depressed peak shortening and maximal velocity of shortening/relengthening, prolonged duration of relengthening, and dampened intracellular Ca2+ rise and clearance. Western blot analysis revealed disrupted phosphorylation of insulin receptor, post-receptor signaling molecules IRS-1 (tyrosine/serine phosphorylation), Akt, GSK3β, Foxo3a, mTOR, as well as downregulated expression of mitochondrial proteins PPARγ coactivator 1α (PGC1α) and UCP-2. Intriguingly, IGF-1 mitigated high fat diet feeding-induced alterations in ROS, protein and mitochondrial damage, ATP content, apoptosis, myocardial contraction, intracellular Ca2+ handling and insulin signaling, but not whole body glucose intolerance and cardiac hypertrophy. Exogenous IGF-1 treatment also alleviated high fat diet-induced cardiac dysfunction. Our data revealed that IGF-1 alleviates high fat diet-induced cardiac dysfunction despite persistent cardiac remodeling, possibly due to preserved cell survival, mitochondrial function and insulin signaling. PMID:22275536

  10. Evaluation of myocardial damage in Duchenne's muscular dystrophy with thallium-201 myocardial SPECT

    International Nuclear Information System (INIS)

    Tamura, Takuhisa; Shibuya, Noritoshi; Hashiba, Kunitake; Oku, Yasuhiko; Mori, Hideki; Yano, Katsusuke.

    1993-01-01

    Myocardial damage and cardiopulmonary functions in patients with Duchenne's muscular dystrophy (DMD) were assessed using thallium-201 myocardial single-photon emission computed tomography (SPECT) and technetium-99m multigated radionuclide angiography. Twenty-five patients with DMD were divided into 4 groups according to percent of perfusion defect (%PD) calculated by the bull's-eye method and age. PD was detected in 24 (96.0%) of 25 patients with DMD, and it spread from the left ventricular lateral wall to the anterior wall and/or interventricular septum. PD was detected even in a 6-year-old DMD boy. Patients in Group I (%PD≥10% and age<15 years old) were shown to have a higher risk of left-sided heart failure without respiratory failure. Patients in Group II (%PD≥10 and age≥15) showed decreased pulmonary function and worsened arterial blood gas values as compared with Group IV (%PD<10 and age≥15). There was no significant difference in cardiac function among the 4 groups. It is postulated that myocardial damage in Group II patients is dependent primarily on a deficiency of dystrophin and on chronic respiratory failure, and that some of them are at risk of cardiopulmonary failure. It is concluded that myocardial SPECT is useful for the early diagnosis of myocardial damage and evaluation of cardiopulmonary function in DMD patients. (author)

  11. Novel techniques in VUV high-resolution spectroscopy

    NARCIS (Netherlands)

    Ubachs, W.M.G.; Salumbides, E.J.; Eikema, K.S.E.; de Oliveira, N.; Nahon, L.

    2014-01-01

    Novel VUV sources and techniques for VUV spectroscopy are reviewed. Laser-based VUV sources have been developed via non-linear upconversion of laser pulses in the nanosecond (ns), the picosecond (ps), and femtosecond (fs) domain, and are applied in high-resolution gas phase spectroscopic studies.

  12. Duchenne muscular dystrophy: High-resolution melting curve ...

    African Journals Online (AJOL)

    Duchenne muscular dystrophy: High-resolution melting curve analysis as an affordable diagnostic mutation scanning tool in a South African cohort. ... Genetic screening for D/BMD in South Africa currently includes multiple ligase-dependent probe amplification (MLPA) for exonic deletions and duplications and linkage ...

  13. High-Resolution 3 T MR Microscopy Imaging of Arterial Walls

    International Nuclear Information System (INIS)

    Sailer, Johannes; Rand, Thomas; Berg, Andreas; Sulzbacher, Irene; Peloschek, P.; Hoelzenbein, Thomas; Lammer, Johannes

    2006-01-01

    Purpose. To achieve a high spatial resolution in MR imaging that allows for clear visualization of anatomy and even histology and documentation of plaque morphology in in vitro samples from patients with advanced atherosclerosis. A further objective of our study was to evaluate whether T2-weighted high-resolution MR imaging can provide accurate classification of atherosclerotic plaque according to a modified American Heart Association classification. Methods. T2-weighted images of arteries were obtained in 13 in vitro specimens using a 3 T MR unit (Medspec 300 Avance/Bruker, Ettlingen, Germany) combined with a dedicated MR microscopy system. Measurement parameters were: T2-weighted sequences with TR 3.5 sec, TE 15-120 msec; field of view (FOV) 1.4 x 1.4; NEX 8; matrix 192; and slice thickness 600 μm. MR measurements were compared with corresponding histologic sections. Results. We achieved excellent spatial and contrast resolution in all specimens. We found high agreement between MR images and histology with regard to the morphology and extent of intimal proliferations in all but 2 specimens. We could differentiate fibrous caps and calcifications from lipid plaque components based on differences in signal intensity in order to differentiate hard and soft atheromatous plaques. Hard plaques with predominantly intimal calcifications were found in 7 specimens, and soft plaques with a cholesterol/lipid content in 5 cases. In all specimens, hemorrhage or thrombus formation, and fibrotic and hyalinized tissue could be detected on both MR imaging and histopathology. Conclusion. High-resolution, high-field MR imaging of arterial walls demonstrates the morphologic features, volume, and extent of intimal proliferations with high spatial and contrast resolution in in vitro specimens and can differentiate hard and soft plaques

  14. Motivation for an SSC detector with ultra-high resolution photon detection

    International Nuclear Information System (INIS)

    Gunion, J.F.; Kane, G.

    1992-01-01

    It is well known that incorporating ultra-high resolution photon detection into a general purpose detector for the SSC will be extremely difficult. The authors will argue that the physics signals that could be missed without such resolution are of such importance that a special purpose detector designed specifically for photon final state modes should be constructed, if sufficient resolution cannot be achieved with general purpose detectors. The potentially great value of these signals as a probe of extremely high mass scales is stressed

  15. Comparison of Two Grid Refinement Approaches for High Resolution Regional Climate Modeling: MPAS vs WRF

    Science.gov (United States)

    Leung, L.; Hagos, S. M.; Rauscher, S.; Ringler, T.

    2012-12-01

    This study compares two grid refinement approaches using global variable resolution model and nesting for high-resolution regional climate modeling. The global variable resolution model, Model for Prediction Across Scales (MPAS), and the limited area model, Weather Research and Forecasting (WRF) model, are compared in an idealized aqua-planet context with a focus on the spatial and temporal characteristics of tropical precipitation simulated by the models using the same physics package from the Community Atmosphere Model (CAM4). For MPAS, simulations have been performed with a quasi-uniform resolution global domain at coarse (1 degree) and high (0.25 degree) resolution, and a variable resolution domain with a high-resolution region at 0.25 degree configured inside a coarse resolution global domain at 1 degree resolution. Similarly, WRF has been configured to run on a coarse (1 degree) and high (0.25 degree) resolution tropical channel domain as well as a nested domain with a high-resolution region at 0.25 degree nested two-way inside the coarse resolution (1 degree) tropical channel. The variable resolution or nested simulations are compared against the high-resolution simulations that serve as virtual reality. Both MPAS and WRF simulate 20-day Kelvin waves propagating through the high-resolution domains fairly unaffected by the change in resolution. In addition, both models respond to increased resolution with enhanced precipitation. Grid refinement induces zonal asymmetry in precipitation (heating), accompanied by zonal anomalous Walker like circulations and standing Rossby wave signals. However, there are important differences between the anomalous patterns in MPAS and WRF due to differences in the grid refinement approaches and sensitivity of model physics to grid resolution. This study highlights the need for "scale aware" parameterizations in variable resolution and nested regional models.

  16. Toward high-resolution NMR spectroscopy of microscopic liquid samples

    Energy Technology Data Exchange (ETDEWEB)

    Butler, Mark C.; Mehta, Hardeep S.; Chen, Ying; Reardon, Patrick N.; Renslow, Ryan S.; Khbeis, Michael; Irish, Duane; Mueller, Karl T.

    2017-01-01

    A longstanding limitation of high-resolution NMR spectroscopy is the requirement for samples to have macroscopic dimensions. Commercial probes, for example, are designed for volumes of at least 5 mL, in spite of decades of work directed toward the goal of miniaturization. Progress in miniaturizing inductive detectors has been limited by a perceived need to meet two technical requirements: (1) minimal separation between the sample and the detector, which is essential for sensitivity, and (2) near-perfect magnetic-field homogeneity at the sample, which is typically needed for spectral resolution. The first of these requirements is real, but the second can be relaxed, as we demonstrate here. By using pulse sequences that yield high-resolution spectra in an inhomogeneous field, we eliminate the need for near-perfect field homogeneity and the accompanying requirement for susceptibility matching of microfabricated detector components. With this requirement removed, typical imperfections in microfabricated components can be tolerated, and detector dimensions can be matched to those of the sample, even for samples of volume << 5 uL. Pulse sequences that are robust to field inhomogeneity thus enable small-volume detection with optimal sensitivity. We illustrate the potential of this approach to miniaturization by presenting spectra acquired with a flat-wire detector that can easily be scaled to subnanoliter volumes. In particular, we report high-resolution NMR spectroscopy of an alanine sample of volume 500 pL.

  17. Assessment of myocardial infarction by magnetic resonance imaging with the aid of contrast agents

    International Nuclear Information System (INIS)

    Roos, A. de; Doornbos, J.

    1991-01-01

    The potential of MR imaging in myocardial ischemia with low-temporal-resolution spin-echo techniques both with and without MR contrast agents has been explored. There are indications that early MR imaging after administration of Gd-DTPA is capable to differentiate reperfused from non-reperfused infarcts. Furthermore, MR infarct sizing using Gd-DTPA is feasible to demonstrate infarct size reduction in patients with successful reperfusion. (H.W.). 50 refs.; 9 figs

  18. Gamma-Ray Imager With High Spatial And Spectral Resolution

    Science.gov (United States)

    Callas, John L.; Varnell, Larry S.; Wheaton, William A.; Mahoney, William A.

    1996-01-01

    Gamma-ray instrument developed to enable both two-dimensional imaging at relatively high spatial resolution and spectroscopy at fractional-photon-energy resolution of about 10 to the negative 3rd power in photon-energy range from 10 keV to greater than 10 MeV. In its spectroscopic aspect, instrument enables identification of both narrow and weak gamma-ray spectral peaks.

  19. Predictors of fatal outcome in acute myocardial infarction

    International Nuclear Information System (INIS)

    Qureshi, O.; Mughal, M.M.

    2008-01-01

    Myocardial infarction is one of the most common life threatening diagnoses in emergency hospital admissions. Most of the complications occur during the first few hours while the patients are likely to be in the hospital. Although the mortality rate after admission for myocardial infarction has declined significantly over the last two decades but it still remains high. Survival is markedly influenced by age of the patient, presence of different risk factors and complications that patients develop after myocardial infarction. We conducted a study at Armed Forces Institute of Cardiology/National Institute of Heart Diseases (AFIC/NIHD) to document the predictors of mortality in patients with acute myocardial infarction. Patients with first acute myocardial infarction admitted to the hospital from Feb. 2007 to June 2007 were included in the study. It was a descriptive case series study and data was collected on a pre-designed proforma with convenient sampling technique. Patients were assessed clinically with special emphasis on history of typical chest pain and physical examination. Relevant investigations were carried out to establish the diagnosis. Two hundred and fifty cases were assessed. Mean age was 57.94+-14.00 years. Males were 74.4% and Females were 25.6%. Overall in-hospital mortality was 9.2%. Females had a higher mortality (14.06%) as compared to males (7.52%). Mortality was also related with age of the patient and Diabetes Mellitus. Other features adversely affecting the in-hospital mortality included higher Killip class, anterior wall myocardial infarction and higher peak Creatine Kinase (CK) levels. Mortality was also higher in patients who did not receive thrombolytic therapy for different reasons. Patients with certain risk factors are more prone to develop complications and have a higher mortality rate. Identification of some of these risk factors and timely management of complications may reduce mortality. (author)

  20. Fuzzy Classification of High Resolution Remote Sensing Scenes Using Visual Attention Features

    Directory of Open Access Journals (Sweden)

    Linyi Li

    2017-01-01

    Full Text Available In recent years the spatial resolutions of remote sensing images have been improved greatly. However, a higher spatial resolution image does not always lead to a better result of automatic scene classification. Visual attention is an important characteristic of the human visual system, which can effectively help to classify remote sensing scenes. In this study, a novel visual attention feature extraction algorithm was proposed, which extracted visual attention features through a multiscale process. And a fuzzy classification method using visual attention features (FC-VAF was developed to perform high resolution remote sensing scene classification. FC-VAF was evaluated by using remote sensing scenes from widely used high resolution remote sensing images, including IKONOS, QuickBird, and ZY-3 images. FC-VAF achieved more accurate classification results than the others according to the quantitative accuracy evaluation indices. We also discussed the role and impacts of different decomposition levels and different wavelets on the classification accuracy. FC-VAF improves the accuracy of high resolution scene classification and therefore advances the research of digital image analysis and the applications of high resolution remote sensing images.

  1. Variational data assimilation system with nesting model for high resolution ocean circulation

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, Yoichi; Igarashi, Hiromichi; Hiyoshi, Yoshimasa; Sasaki, Yuji; Wakamatsu, Tsuyoshi; Awaji, Toshiyuki [Center for Earth Information Science and Technology, Japan Agency for Marine-Earth Science and Technology, 3173-25 Showa-machi, Kanazawa-Ku, Yokohama 236-0001 (Japan); In, Teiji [Japan Marine Science Foundation, 4-24, Minato-cho, Mutsu, Aomori, 035-0064 (Japan); Nakada, Satoshi [Graduate School of Maritime Science, Kobe University, 5-1-1, Fukae-minamimachi, Higashinada-Ku, Kobe, 658-0022 (Japan); Nishina, Kei, E-mail: ishikaway@jamstec.go.jp [Graduate School of Science, Kyoto University, Kitashirakawaoiwake-cho, Sakyo-Ku, Kyoto, 606-8502 (Japan)

    2015-10-15

    To obtain the high-resolution analysis fields for ocean circulation, a new incremental approach is developed using a four-dimensional variational data assimilation system with nesting models. The results show that there are substantial biases when using a classical method combined with data assimilation and downscaling, caused by different dynamics resulting from the different resolutions of the models used within the nesting models. However, a remarkable reduction in biases of the low-resolution model relative to the high-resolution model was observed using our new approach in narrow strait regions, such as the Tsushima and Tsugaru straits, where the difference in the dynamics represented by the high- and low-resolution models is substantial. In addition, error reductions are demonstrated in the downstream region of these narrow channels associated with the propagation of information through the model dynamics. (paper)

  2. Real-time database for high resolution neutron monitor measurements

    Energy Technology Data Exchange (ETDEWEB)

    Steigies, Christian T.; Rother, Oliver M.; Wimmer-Schweingruber, Robert F.; Heber, Bernd [IEAP, Christian-Albrechts-Universitaet zu Kiel (Germany)

    2008-07-01

    The worldwide network of standardised neutron monitors is, after 50 years, still the state-of-the-art instrumentation to measure spectral variations of the primary cosmic ray component. These measurements are an ideal complement to space based cosmic ray measurements. Data from the approximately 50 IGY and NM64 neutron monitors is stored locally but also available through data collections sites like the World Data Center (WDC) or the IZMIRAN ftp server. The data from the WDC is in a standard format, but only hourly values are available. IZMIRAN collects the data in the best available time resolution, but the data arrives on the ftp server only hours, sometimes days, after the measurements. Also, the high time-resolution measurements of the different stations do not have a common format, a conversion routine for each station is needed before they can be used for scientific analysis. Supported by the 7th framework program of the European Commission, we are setting up a real-time database where high resolution cosmic ray measurements will be stored and accessible immediately after the measurement. Stations that do not have 1-minute resolution measurements will be upgraded to 1-minute or better resolution with an affordable standard registration system, that will submit the measurements to the database via the internet in real-time.

  3. High resolution imaging of boron carbide microstructures

    International Nuclear Information System (INIS)

    MacKinnon, I.D.R.; Aselage, T.; Van Deusen, S.B.

    1986-01-01

    Two samples of boron carbide have been examined using high resolution transmission electron microscopy (HRTEM). A hot-pressed B 13 C 2 sample shows a high density of variable width twins normal to (10*1). Subtle shifts or offsets of lattice fringes along the twin plane and normal to approx.(10*5) were also observed. A B 4 C powder showed little evidence of stacking disorder in crystalline regions

  4. A subspace approach to high-resolution spectroscopic imaging.

    Science.gov (United States)

    Lam, Fan; Liang, Zhi-Pei

    2014-04-01

    To accelerate spectroscopic imaging using sparse sampling of (k,t)-space and subspace (or low-rank) modeling to enable high-resolution metabolic imaging with good signal-to-noise ratio. The proposed method, called SPectroscopic Imaging by exploiting spatiospectral CorrElation, exploits a unique property known as partial separability of spectroscopic signals. This property indicates that high-dimensional spectroscopic signals reside in a very low-dimensional subspace and enables special data acquisition and image reconstruction strategies to be used to obtain high-resolution spatiospectral distributions with good signal-to-noise ratio. More specifically, a hybrid chemical shift imaging/echo-planar spectroscopic imaging pulse sequence is proposed for sparse sampling of (k,t)-space, and a low-rank model-based algorithm is proposed for subspace estimation and image reconstruction from sparse data with the capability to incorporate prior information and field inhomogeneity correction. The performance of the proposed method has been evaluated using both computer simulations and phantom studies, which produced very encouraging results. For two-dimensional spectroscopic imaging experiments on a metabolite phantom, a factor of 10 acceleration was achieved with a minimal loss in signal-to-noise ratio compared to the long chemical shift imaging experiments and with a significant gain in signal-to-noise ratio compared to the accelerated echo-planar spectroscopic imaging experiments. The proposed method, SPectroscopic Imaging by exploiting spatiospectral CorrElation, is able to significantly accelerate spectroscopic imaging experiments, making high-resolution metabolic imaging possible. Copyright © 2014 Wiley Periodicals, Inc.

  5. Myocardial imaging in acute myocardial infarction using β-methyl-p-(123I)-iodophenylpentadecanoic acid

    International Nuclear Information System (INIS)

    Naruse, Hitoshi; Itano, Midoriko; Kondo, Tomohiro

    1992-01-01

    Myocardial imaging using β-methyl-p-( 123 I)-iodophenylpentadecanoic acid (BMIPP) was performed in 11 patients with acute myocardial infarction. The left ventricular images were divided into 12 segments, and myocardial images with BMIPP were compared with coronary angiography (CAG), thallium-201 myocardial scintigraphy (Tl) and wall motion obtained by two-dimensional echocardiography (WM). When the culprit lesion was at the proximal point of the left anterior descending artery (LAD), all segments showed depressed uptake. In 3 cases with single vessel disease of the LAD, inferior wall of the basis showed reduced uptake of BMIPP despite the location of the culprit lesion. In cases with discordant uptake between the two tracers, BMIPP frequently showed more severely depressed uptake than Tl in the subacute phase, although the uptake of BMIPP correlated with that of Tl (τ=0.82, p<0.001). In such cases, the discordance was related to the improvement in WM from the acute phase to the convalescent phase. BMIPP uptake correlated with WM in the subacute phase (τ=0.50, p<0.001). BMIPP showed more severely depressed uptake while WM showed mild asynergy in most cases in which discordance was found between the BMIPP and WM findings. However, there was no correlation between the change in WM from the acute to subacute phases, or the uptakes of BMIPP and Tl alone. We concluded that the myocardial condition can be evaluated in detail in acute myocardial infarction by comparing the findings of BMIPP with those of Tl and WM. (author)

  6. High-resolution spectroscopic probes of collisions and half-collisions

    Energy Technology Data Exchange (ETDEWEB)

    Hall, G.E. [Brookhaven National Laboratory, Upton, NY (United States)

    1993-12-01

    Research in this program explores the dynamics of gas phase collisions and photodissociation by high-resolution laser spectroscopy. Simultaneous state and velocity detection frequently permits a determination of scalar or vector correlations among products. The correlated product distributions are always more informative, and often easier to interpret than the uncorrelated product state distributions. The authors have recently built an apparatus to record transient absorption spectra with 50 nS time resolution and 20 MHz frequency resolution using a single frequency Ti:sapphire laser. The photodissociation of NCCN and C{sub 2}H{sub 5}SCN at 193 nm is discussed.

  7. The demonstration of the auditory ossicles by high resolution CT

    International Nuclear Information System (INIS)

    Lloyd, G.A.S.; Boulay, G.H. du; Phelps, P.D.; Pullicino, P.

    1979-01-01

    The high resolution CT scanning system introduced by EMI in 1978 has added a new dimension to computerised tomography in otology. The apparatus used for this study was an EMI CT 5005 body scanner adapted for head and neck scanning and incorporating a high resolution facility. The latter has proved most advantageous in areas of relatively high differential absorption, so that its application to the demonstration of abnormalities in the petrous temporal bone, and in particular middle ear disease, has been very rewarding. Traumatic ossicular disruptions may now be demonstrated and the high contrast of CT often shows them better than conventional hypocycloidal tomography. The stapes is also better visualised and congenital abnormalities of its superstructure have been recorded. These studies have been achieved with a very acceptable level of radiation to the eye, lens and cornea and the technique is clearly a rival to conventional pluridirectional tomography in the assessment of the petrous temporal bone. With further design improvements high resolution CT could completely replace existing techniques. (orig.) [de

  8. Statins and perioperative myocardial infarction. | Levin | Southern ...

    African Journals Online (AJOL)

    The growing prevalence of atherosclerosis means that perioperative myocardial infarction (PMI) is of significant concern to anesthesiologists. Perioperative revascularization (if indicated medically), beta blockade (in high risk patients) and statin therapy are therapeutic modalities that are currently employed to reduce PMI.

  9. Detecting Myocardial Ischemia With 99mTechnetium-Tetrofosmin Myocardial Perfusion Imaging in Ischemic Stroke.

    Science.gov (United States)

    Giannopoulos, Sotirios; Markoula, Sofia; Sioka, Chrissa; Zouroudi, Sofia; Spiliotopoulou, Maria; Naka, Katerina K; Michalis, Lampros K; Fotopoulos, Andreas; Kyritsis, Athanassios P

    2017-10-01

    To assess the myocardial status in patients with stroke, employing myocardial perfusion imaging (MPI) with 99m Technetium-tetrofosmin ( 99m Tc-TF)-single-photon emission computed tomography (SPECT). Fifty-two patients with ischemic stroke were subjected to 99m Tc-TF-SPECT MPI within 1 month after stroke occurrence. None of the patients had any history or symptoms of coronary artery disease or other heart disease. Myocardial perfusion imaging was evaluated visually using a 17-segment polar map. Myocardial ischemia (MIS) was defined as present when the summed stress score (SSS) was >4; MIS was defined as mild when SSS was 4 to 8, and moderate/severe with SSS ≥9. Patients with SSS >4 were compared to patients with SSS SSS >9 were compared to patients with SSS SSS, with the oldest age exhibiting the highest SSS ( P = .01). The association of age with SSS remained statistically significant in the multivariate analysis ( P = .04). The study suggested that more than half of patients with stroke without a history of cardiac disease have MIS. Although most of them have mild MIS, we suggest a thorough cardiological evaluation in this group of patients for future prevention of severe myocardial outcome.

  10. High resolution NMR theory and chemical applications

    CERN Document Server

    Becker, Edwin D

    2012-01-01

    High Resolution NMR: Theory and Chemical Applications discusses the principles and theory of nuclear magnetic resonance and how this concept is used in the chemical sciences. This book is written at an intermediate level, with mathematics used to augment verbal descriptions of the phenomena. This text pays attention to developing and interrelating four approaches - the steady state energy levels, the rotating vector picture, the density matrix, and the product operator formalism. The style of this book is based on the assumption that the reader has an acquaintance with the general principles of quantum mechanics, but no extensive background in quantum theory or proficiency in mathematics is required. This book begins with a description of the basic physics, together with a brief account of the historical development of the field. It looks at the study of NMR in liquids, including high resolution NMR in the solid state and the principles of NMR imaging and localized spectroscopy. This book is intended to assis...

  11. Principles of high resolution NMR in solids

    CERN Document Server

    Mehring, Michael

    1983-01-01

    The field of Nuclear Magnetic Resonance (NMR) has developed at a fascinating pace during the last decade. It always has been an extremely valuable tool to the organic chemist by supplying molecular "finger print" spectra at the atomic level. Unfortunately the high resolution achievable in liquid solutions could not be obtained in solids and physicists and physical chemists had to live with unresolved lines open to a wealth of curve fitting procedures and a vast amount of speculations. High resolution NMR in solids seemed to be a paradoxon. Broad structure­ less lines are usually encountered when dealing with NMR in solids. Only with the recent advent of mUltiple pulse, magic angle, cross-polarization, two-dimen­ sional and multiple-quantum spectroscopy and other techniques during the last decade it became possible to resolve finer details of nuclear spin interactions in solids. I have felt that graduate students, researchers and others beginning to get involved with these techniques needed a book which trea...

  12. High resolution NMR theory and chemical applications

    CERN Document Server

    Becker, Edwin D

    1999-01-01

    High Resolution NMR provides a broad treatment of the principles and theory of nuclear magnetic resonance (NMR) as it is used in the chemical sciences. It is written at an "intermediate" level, with mathematics used to augment, rather than replace, clear verbal descriptions of the phenomena. The book is intended to allow a graduate student, advanced undergraduate, or researcher to understand NMR at a fundamental level, and to see illustrations of the applications of NMR to the determination of the structure of small organic molecules and macromolecules, including proteins. Emphasis is on the study of NMR in liquids, but the treatment also includes high resolution NMR in the solid state and the principles of NMR imaging and localized spectroscopy. Careful attention is given to developing and interrelating four approaches - steady state energy levels, the rotating vector picture, the density matrix, and the product operator formalism. The presentation is based on the assumption that the reader has an acquaintan...

  13. Association between aortic valve calcification and myocardial ischemia, especially in asymptomatic patients.

    Science.gov (United States)

    Yamazato, Ryo; Yamamoto, Hideya; Tadehara, Futoshi; Teragawa, Hiroki; Kurisu, Satoshi; Dohi, Yoshihiro; Ishibashi, Ken; Kunita, Eiji; Utsunomiya, Hiroto; Oka, Toshiharu; Kihara, Yasuki

    2012-08-01

    Aortic valve calcification (AVC) is recognized as a manifestation of systemic arteriosclerosis. However, it is unclear whether AVC is associated with myocardial ischemia. Stress myocardial perfusion SPECT (MPS) is widely used for the diagnosis of myocardial ischemia. However, routine MPS is not recommended, particularly in asymptomatic patients. Accordingly, we investigated the hypothesis that the presence of AVC is strongly associated with inducible myocardial ischemia, even among asymptomatic patients. We investigated 669 consecutive patients who underwent both adenosine stress (201)Tl MPS and echocardiography. We evaluated the extent and severity of myocardial ischemia by the summed difference score (SDS). We defined the presence of myocardial ischemia as SDS ≥ 3 and moderate to severe ischemia as SDS ≥ 8. We classified the severity of AVC according to the number of affected aortic leaflets. We also compared the mean SDS and the prevalence of SDS ≥ 3 and SDS ≥ 8 among patients stratified by the severity of AVC. The presence of AVC was significantly associated with myocardial ischemia (odds ratio [OR], 1.56; 95% confidence interval [CI], 1.10-2.23; P = 0.013) and moderate to severe ischemia (OR, 2.16; 95% CI, 1.26-3.80; P = 0.0061). In 311 asymptomatic patients, AVC was strongly associated with moderate to severe ischemia (OR, 4.31; 95% CI, 1.67-12.8; P = 0.0043). However, the SDS value and the prevalence of SDS ≥ 3 and SDS ≥ 8 did not increase with increasing number of affected aortic leaflets. The presence of AVC may be associated with the presence of myocardial ischemia, particularly in asymptomatic patients. However, we found no association between the extent of AVC and inducible myocardial ischemia. The presence of AVC may be a useful anatomic marker to help identify patients at high risk of myocardial ischemia, particularly asymptomatic patients.

  14. High resolution study of high mass pairs and high transverse momentum particles

    International Nuclear Information System (INIS)

    Smith, S.R.

    1983-01-01

    Preliminary experiments involving the high resolution spectrometer (experiment 605) at Fermilab are described. The spectrometer is designed for the study of pairs of particles at large invariant masses and single particles at large transverse momenta. A number of applications of the apparatus in the study of Drell-Yan processes, e.g. transverse momentum measurement, are discussed

  15. Ventricular and myocardial scintiscanning: Methodical fundamentals

    International Nuclear Information System (INIS)

    Standke, R.; Hoer, G.; Maul, F.D.

    1984-01-01

    Nuclear cardiology is concerned with non invasive procedures to quantitate global and regional left ventricular function (Radionuclide ventriculography), also the imaging of vitally perfused myocardium (Myocardial scintigraphy) is achieved. A gammacamera and a minicomputer are necessary. Radionuclide ventriculography enables the analysis of global and regional time dependent left ventricular volume curves and hence the evaluation of contraction and contractility of the heart muscle. The basis is a sequence of scans covering an average heartcycle. This sequence may be produced either by first pass or equilibrium technique. Myocardial scintigraphy at rest images vital myocardium, scans immediately after exercise represent the interference of myocardial perfusion and muscle mass. The regional difference (Redistribution) between normalized exercise- and rest scans provide quantitative parameters to detect impairment of exercise-induced myocardial perfusion anomalies. The procedures of sectorial analysis of left ventricular function and myocardial perfusion are presented. (orig.) [de

  16. Fenofibrate Therapy Restores Antioxidant Protection and Improves Myocardial Insulin Resistance in a Rat Model of Metabolic Syndrome and Myocardial Ischemia: The Role of Angiotensin II

    Directory of Open Access Journals (Sweden)

    Luz Ibarra-Lara

    2016-12-01

    Full Text Available Renin-angiotensin system (RAS activation promotes oxidative stress which increases the risk of cardiac dysfunction in metabolic syndrome (MetS and favors local insulin resistance. Fibrates regulate RAS improving MetS, type-2 diabetes and cardiovascular diseases. We studied the effect of fenofibrate treatment on the myocardic signaling pathway of Angiotensin II (Ang II/Angiotensin II type 1 receptor (AT1 and its relationship with oxidative stress and myocardial insulin resistance in MetS rats under heart ischemia. Control and MetS rats were assigned to the following groups: (a sham; (b vehicle-treated myocardial infarction (MI (MI-V; and (c fenofibrate-treated myocardial infarction (MI-F. Treatment with fenofibrate significantly reduced triglycerides, non-high density lipoprotein cholesterol (non-HDL-C, insulin levels and insulin resistance index (HOMA-IR in MetS animals. MetS and MI increased Ang II concentration and AT1 expression, favored myocardial oxidative stress (high levels of malondialdehyde, overexpression of nicotinamide adenine dinucleotide phosphate (NADPH oxidase 4 (NOX4, decreased total antioxidant capacity and diminished expression of superoxide dismutase (SOD1, SOD2 and catalase and inhibited expression of the insulin signaling cascade: phosphatidylinositol 3-kinase (PI3K/protein kinase B (PkB, also known as Akt/Glut-4/endothelial nitric oxide synthase (eNOS. In conclusion, fenofibrate treatment favors an antioxidant environment as a consequence of a reduction of the Ang II/AT1/NOX4 signaling pathway, reestablishing the cardiac insulin signaling pathway. This might optimize cardiac metabolism and improve the vasodilator function during myocardial ischemia.

  17. Study of thallium scintigraphy for myocardial infarction performed within 72 hours of attack

    Energy Technology Data Exchange (ETDEWEB)

    Setsuda, Koichi; Tomita, Yoshifumi; Takayama, Morimasa (Nippon Medical School, Tokyo)

    1983-11-01

    In 40 cases undergoing /sup 201/Tl myocardial scanning within 72 hours of attack of myocardial infarction, a significant correlation was found between the infarct size determined by myocardial scanning and the size of the infarction estimated on the basis of ECG findings and serum enzymes. The group with high pulmonary capillary wedge pressure was the group with low Tl scores. The group showing dyskinesis and aneurysm in left ventriculography showed low Tl scores and a significant correlation between the ejection fraction calculated from left ventriculograms and the Tl score. The above date indicate that /sup 201/Tl myocardial scanning in the acute phase after attack of infarction reflects the infarction size and cardiac function.

  18. Localization-based super-resolution imaging meets high-content screening.

    Science.gov (United States)

    Beghin, Anne; Kechkar, Adel; Butler, Corey; Levet, Florian; Cabillic, Marine; Rossier, Olivier; Giannone, Gregory; Galland, Rémi; Choquet, Daniel; Sibarita, Jean-Baptiste

    2017-12-01

    Single-molecule localization microscopy techniques have proven to be essential tools for quantitatively monitoring biological processes at unprecedented spatial resolution. However, these techniques are very low throughput and are not yet compatible with fully automated, multiparametric cellular assays. This shortcoming is primarily due to the huge amount of data generated during imaging and the lack of software for automation and dedicated data mining. We describe an automated quantitative single-molecule-based super-resolution methodology that operates in standard multiwell plates and uses analysis based on high-content screening and data-mining software. The workflow is compatible with fixed- and live-cell imaging and allows extraction of quantitative data like fluorophore photophysics, protein clustering or dynamic behavior of biomolecules. We demonstrate that the method is compatible with high-content screening using 3D dSTORM and DNA-PAINT based super-resolution microscopy as well as single-particle tracking.

  19. High-resolution RCMs as pioneers for future GCMs

    Science.gov (United States)

    Schar, C.; Ban, N.; Arteaga, A.; Charpilloz, C.; Di Girolamo, S.; Fuhrer, O.; Hoefler, T.; Leutwyler, D.; Lüthi, D.; Piaget, N.; Ruedisuehli, S.; Schlemmer, L.; Schulthess, T. C.; Wernli, H.

    2017-12-01

    Currently large efforts are underway to refine the horizontal resolution of global and regional climate models to O(1 km), with the intent to represent convective clouds explicitly rather than using semi-empirical parameterizations. This refinement will move the governing equations closer to first principles and is expected to reduce the uncertainties of climate models. High resolution is particularly attractive in order to better represent critical cloud feedback processes (e.g. related to global climate sensitivity and extratropical summer convection) and extreme events (such as heavy precipitation events, floods, and hurricanes). The presentation will be illustrated using decade-long simulations at 2 km horizontal grid spacing, some of these covering the European continent on a computational mesh with 1536x1536x60 grid points. To accomplish such simulations, use is made of emerging heterogeneous supercomputing architectures, using a version of the COSMO limited-area weather and climate model that is able to run entirely on GPUs. Results show that kilometer-scale resolution dramatically improves the simulation of precipitation in terms of the diurnal cycle and short-term extremes. The modeling framework is used to address changes of precipitation scaling with climate change. It is argued that already today, modern supercomputers would in principle enable global atmospheric convection-resolving climate simulations, provided appropriately refactored codes were available, and provided solutions were found to cope with the rapidly growing output volume. A discussion will be provided of key challenges affecting the design of future high-resolution climate models. It is suggested that km-scale RCMs should be exploited to pioneer this terrain, at a time when GCMs are not yet available at such resolutions. Areas of interest include the development of new parameterization schemes adequate for km-scale resolution, the exploration of new validation methodologies and data

  20. Application of 123I-labelled long-chained fatty acids for the study of myocardial metabolism

    International Nuclear Information System (INIS)

    Freundlieb, C.; Hoeck, A.; Vyska, F.; Feinendegen, L.E.; Machulla, H.J.; Stoecklin, G.

    1978-01-01

    Radioiodine-labelled fatty acids are useful tracers for myocardial imaging. The present study extends myocardial scintigraphy with ω-123-I-heptadecanoic acid to measuring myocardial metabolism. 4 normal individuals and 6 patients with cardiac disease received i.v. 1-2 mCi ω-123-I-heptadecanoic acid. Immediately fast serial scintigrams of the myocardium were taken for 30 minutes. Disappearance of the tracer, and appearance of anorganic 123-I, was measured in the peripheral blood. The myocardial images were of high quality later than 5 minutes after injection. By correcting for anorganic 123-I in the peripheral blood and the interstitium, the turnover of tracer in the myocardial cells could be measured. Activity was lost from the myocardium with a half time between 14 and 32 minutes. Within regions of old myocardials infarctions the half time of tracer loss was prolonged. The data clearly indicate the feasibility of using ω-123-I-heptadecanoic acid for measuring myocardial metabolism. (author)

  1. Effect of collateral circulation on myocardial protection in patients with acute myocardial infarction. Comparison of technetium-99m-tetrofosmin myocardial single photon emission computed tomography and coronary angiography

    International Nuclear Information System (INIS)

    Yoshida, Michi; Kondo, Makoto; Abe, Yoshiteru; Kubota, Tomoyuki; Matsuoka, Ryota; Araki, Makoto; Tanio, Hitoshi; Doyama, Kiyoshi

    2006-01-01

    Evaluation of myocardial blood flow from collateral vessels into the infarct area has been estimated by coronary angiography. In patients with acute myocardial infarction with Thrombolysis in Myocardial Infarction (TIMI) 0 flow, myocardial tracer uptake on single photon emission computed tomography (SPECT) images can predict the collateral blood flow in the infarct area if technetium (Tc)-99m-tetrofosmin was administered before recanalization. The present study investigated whether collateral blood flow evaluated by myocardial scintigraphy is a good predictor of myocardial salvage in patients with acute myocardial infarction. The study group consisted of 30 patients (mean age 65±14 years, 23 males, 7 females) with first acute myocardial infarction and coronary angiography evidence of total occlusion (TIMI 0) within 12 hr after the onset. All patients had one vessel disease related to infarction and TIMI 3 flow after percutaneous coronary intervention (PCI). Tc-99m-tetrofosmin was injected intravenously before the PCI. The regional severity score index (RSSI) was obtained from SPECT using the 17 segment method with the four-point scoring system. Myocardial viability was evaluated by the RSSI obtained from thallium-glucose-insulin infusion SPECT after 1 week and regional wall motion score index obtained from echocardiography during the chronic phase. The patients were divided into two groups according to the angiographic collateral finding. There were no differences in RSSI on thallium-glucose-insulin SPECT and regional wall motion score between the good collateral group (n=8) and poor collateral group (n=22). Myocardial Tc-99m-tetrofosmin RSSI was similar in these groups. On the other hand, the patients were divided according to Tc-99m-tetrofosmin scintigraphic evaluation before PCI. RSSI on thallium-glucose-insulin SPECT was significantly greater (0.7±0.5 vs 1.5±0.4, p<0.01) and regional wall motion score was significantly less (1.46±0.50 vs 2.08±0.78, p<0

  2. Methylation-Sensitive High Resolution Melting (MS-HRM).

    Science.gov (United States)

    Hussmann, Dianna; Hansen, Lise Lotte

    2018-01-01

    Methylation-Sensitive High Resolution Melting (MS-HRM) is an in-tube, PCR-based method to detect methylation levels at specific loci of interest. A unique primer design facilitates a high sensitivity of the assays enabling detection of down to 0.1-1% methylated alleles in an unmethylated background.Primers for MS-HRM assays are designed to be complementary to the methylated allele, and a specific annealing temperature enables these primers to anneal both to the methylated and the unmethylated alleles thereby increasing the sensitivity of the assays. Bisulfite treatment of the DNA prior to performing MS-HRM ensures a different base composition between methylated and unmethylated DNA, which is used to separate the resulting amplicons by high resolution melting.The high sensitivity of MS-HRM has proven useful for detecting cancer biomarkers in a noninvasive manner in urine from bladder cancer patients, in stool from colorectal cancer patients, and in buccal mucosa from breast cancer patients. MS-HRM is a fast method to diagnose imprinted diseases and to clinically validate results from whole-epigenome studies. The ability to detect few copies of methylated DNA makes MS-HRM a key player in the quest for establishing links between environmental exposure, epigenetic changes, and disease.

  3. High-resolution MR imaging of talar osteochondral lesions with new classification

    Energy Technology Data Exchange (ETDEWEB)

    Griffith, James Francis; Lau, Domily Ting Yi; Yeung, David Ka Wai [Prince of Wales Hospital, Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Shatin, NT (China); Wong, Margaret Wan Nar [Prince of Wales Hospital, Chinese University of Hong Kong, Department of Orthopaedics and Traumatology, Shatin (China)

    2012-04-15

    Retrospective review of high-resolution MR imaging features of talar dome osteochondral lesions and development of new classification system based on these features. Over the past 7 years, 70 osteochondral lesions of the talar dome from 70 patients (49 males, 21 females, mean age 42 years, range 15-62 years) underwent high-resolution MR imaging with a microscopy coil at 1.5 T. Sixty-one (87%) of 70 lesions were located on the medial central aspect and ten (13%) lesions were located on the lateral central aspect of the talar dome. Features evaluated included cartilage fracture, osteochondral junction separation, subchondral bone collapse, bone:bone separation, and marrow change. Based on these findings, a new five-part grading system was developed. Signal-to-noise characteristics of microscopy coil imaging at 1.5 T were compared to dedicated ankle coil imaging at 3 T. Microscopy coil imaging at 1.5 T yielded 20% better signal-to-noise characteristics than ankle coil imaging at 3 T. High-resolution MR revealed that osteochondral junction separation, due to focal collapse of the subchondral bone, was a common feature, being present in 28 (45%) of 61 medial central osteochondral lesions. Reparative cartilage hypertrophy and bone:bone separation in the absence of cartilage fracture were also common findings. Complete osteochondral separation was uncommon. A new five-part grading system incorporating features revealed by high-resolution MR imaging was developed. High-resolution MRI reveals clinically pertinent features of talar osteochondral lesions, which should help comprehension of symptomatology and enhance clinical decision-making. These features were incorporated in a new MR-based grading system. Whenever possible, symptomatic talar osteochondral lesions should be assessed by high-resolution MR imaging. (orig.)

  4. High-resolution MR imaging of talar osteochondral lesions with new classification

    International Nuclear Information System (INIS)

    Griffith, James Francis; Lau, Domily Ting Yi; Yeung, David Ka Wai; Wong, Margaret Wan Nar

    2012-01-01

    Retrospective review of high-resolution MR imaging features of talar dome osteochondral lesions and development of new classification system based on these features. Over the past 7 years, 70 osteochondral lesions of the talar dome from 70 patients (49 males, 21 females, mean age 42 years, range 15-62 years) underwent high-resolution MR imaging with a microscopy coil at 1.5 T. Sixty-one (87%) of 70 lesions were located on the medial central aspect and ten (13%) lesions were located on the lateral central aspect of the talar dome. Features evaluated included cartilage fracture, osteochondral junction separation, subchondral bone collapse, bone:bone separation, and marrow change. Based on these findings, a new five-part grading system was developed. Signal-to-noise characteristics of microscopy coil imaging at 1.5 T were compared to dedicated ankle coil imaging at 3 T. Microscopy coil imaging at 1.5 T yielded 20% better signal-to-noise characteristics than ankle coil imaging at 3 T. High-resolution MR revealed that osteochondral junction separation, due to focal collapse of the subchondral bone, was a common feature, being present in 28 (45%) of 61 medial central osteochondral lesions. Reparative cartilage hypertrophy and bone:bone separation in the absence of cartilage fracture were also common findings. Complete osteochondral separation was uncommon. A new five-part grading system incorporating features revealed by high-resolution MR imaging was developed. High-resolution MRI reveals clinically pertinent features of talar osteochondral lesions, which should help comprehension of symptomatology and enhance clinical decision-making. These features were incorporated in a new MR-based grading system. Whenever possible, symptomatic talar osteochondral lesions should be assessed by high-resolution MR imaging. (orig.)

  5. High resolution positron tomography

    International Nuclear Information System (INIS)

    Brownell, G.L.; Burnham, C.A.

    1982-01-01

    The limits of spatial resolution in practical positron tomography are examined. The four factors that limit spatial resolution are: positron range; small angle deviation; detector dimensions and properties; statistics. Of these factors, positron range may be considered the fundamental physical limitation since it is independent of instrument properties. The other factors are to a greater or lesser extent dependent on the design of the tomograph

  6. High-intensity xenon plasma discharge lamp for bulk-sensitive high-resolution photoemission spectroscopy.

    Science.gov (United States)

    Souma, S; Sato, T; Takahashi, T; Baltzer, P

    2007-12-01

    We have developed a highly brilliant xenon (Xe) discharge lamp operated by microwave-induced electron cyclotron resonance (ECR) for ultrahigh-resolution bulk-sensitive photoemission spectroscopy (PES). We observed at least eight strong radiation lines from neutral or singly ionized Xe atoms in the energy region of 8.4-10.7 eV. The photon flux of the strongest Xe I resonance line at 8.437 eV is comparable to that of the He Ialpha line (21.218 eV) from the He-ECR discharge lamp. Stable operation for more than 300 h is achieved by efficient air-cooling of a ceramic tube in the resonance cavity. The high bulk sensitivity and high-energy resolution of PES using the Xe lines are demonstrated for some typical materials.

  7. High resolution, position sensitive detector for energetic particle beams

    International Nuclear Information System (INIS)

    Marsh, E.P.; Strathman, M.D.; Reed, D.A.; Odom, R.W.; Morse, D.H.; Pontau, A.E.

    1993-01-01

    The performance and design of an imaging position sensitive, particle beam detector will be presented. The detector is minimally invasive, operates a wide dynamic range (>10 10 ), and exhibits high spatial resolution. The secondary electrons produced when a particle beam passes through a thin foil are imaged using stigmatic ion optics onto a two-dimensional imaging detector. Due to the low scattering cross section of the 6 nm carbon foil the detector is a minimal perturbation on the primary beam. A prototype detector with an image resolution of approximately 5 μm for a field of view of 1 mm has been reported. A higher resolution detector for imaging small beams (<50 μm) with an image resolution of better than 0.5 μm has since been developed and its design is presented. (orig.)

  8. Silent myocardial ischemia in patients with symptomatic intracranial atherosclerosis: associated factors.

    Science.gov (United States)

    Arenillas, Juan F; Candell-Riera, Jaume; Romero-Farina, Guillermo; Molina, Carlos A; Chacón, Pilar; Aguadé-Bruix, Santiago; Montaner, Joan; de León, Gustavo; Castell-Conesa, Joan; Alvarez-Sabín, José

    2005-06-01

    Optimization of coronary risk evaluation in stroke patients has been encouraged. The relationship between symptomatic intracranial atherosclerosis and occult coronary artery disease (CAD) has not been evaluated sufficiently. We aimed to investigate the prevalence of silent myocardial ischemia in patients with symptomatic intracranial atherosclerosis and to identify factors associated with its presence. From 186 first-ever transient ischemic attack or ischemic stroke patients with intracranial stenoses, 65 fulfilled selection criteria, including angiographic confirmation of a symptomatic atherosclerotic stenosis and absence of known CAD. All patients underwent a maximal-stress myocardial perfusion single-photon emission computed tomography (SPECT). Lipoprotein(a) [Lp(a)], C-reactive protein, and homocysteine (Hcy) levels were determined before SPECT. Stress-rest SPECT detected reversible myocardial perfusion defects in 34 (52%) patients. Vascular risk factors associated with a pathologic SPECT were hypercholesterolemia (P=0.045), presence of >2 risk factors (P=0.004) and high Lp(a) (P=0.023) and Hcy levels (P=0.018). Ninety percent of patients with high Lp(a) and Hcy levels had a positive SPECT. Existence of a stenosed intracranial internal carotid artery (ICA; odds ratio [OR], 7.22, 2.07 to 25.23; P=0.002) and location of the symptomatic stenosis in vertebrobasilar arteries (OR, 4.89, 1.19 to 20.12; P=0.027) were independently associated with silent myocardial ischemia after adjustment by age, sex, and risk factors. More than 50% of the patients with symptomatic intracranial atherosclerosis and not overt CAD show myocardial perfusion defects on stress-rest SPECT. Stenosed intracranial ICA, symptomatic vertebrobasilar stenosis and presence of high Lp(a) and Hcy levels may characterize the patients at a higher risk for occult CAD.

  9. Myocardial viability assessed by Tl-201 SPECT. Redistribution versus reinjection

    International Nuclear Information System (INIS)

    Chalela, William Azem; Pimentel, Flavio Ferrarini de Oliveira; Uchida, Augusto Hiroshi; Bottega, Augusto; Ramires, Jose Antonio Franchine; Izaki, Marisa; Moraes, Aguinaldo Pereira; Soares Junior, Jose; Giorgi, Maria C. Pinto; Moffa, Paulo Jorge; Bellotti, Giovanni; Giovanni Guido Cerri; Meneghetti, Jose Claudio

    1994-01-01

    The purpose of this study was to verify if a third series of images acquired by reinjection thallium-201, 24 h after conventional myocardial perfusion with the radioisotope, improves the identification of myocardial viability segments. The methods: we studied 30 patients, mean age 57.7 ±9.4 years, with old myocardial infarction using thallium (Tl)-201 SPECT, and we obtained three series of images (stress, redistribution after 4 h and reinjection after 24 h. Cardiac images were divided in 5 segments (apical, lateral, anterior, septal and inferior) and each one received a value by a score system according to the Tl-201 myocardial uptake (0=normal uptake; 1=mild hypoperfusion; 2=moderate hypoperfusion; 3=severe hypoperfusion or no myocardial uptake). We considered viable myocardium when the uptake of Tl-201 in the segment related to te myocardial infarction increases at least 1 point in two different axis of Tl-201 SPECT. The results: seven (23,3%) patients demonstrated increase of Tl-201 uptake only at reinjection images, showing a high efficacy of the method. Nine (30%) patients showed persistent hypoperfusion at all series of images suggesting only fibrosis in the are related to the infarction. Fourteen (46,7%) patients showed increase of Tl-201 concentration at redistribution images; among these patients, six showed improvement of myocardial uptake at reinjection. This condition was interpreted as regional chronic ischemic process: hibernating myocardium. The conclusion was that Tl-201 hypoperfusion at redistribution images without significant changes in relation to the stress images do not represent fibrosis at all. The reinjection technic was better than conventional redistribution in the detection of viable myocardium. This data allows a better therapeutic orientation. (author)

  10. The Influence of findings of coronary artery on myocardial salvage in acute myocardial infarction

    International Nuclear Information System (INIS)

    Itano, Midoriko; Naruse, Hitoshi; Morita, Masato; Kawamoto, Hideo; Yamamoto, Juro; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru

    1992-01-01

    201 Tl stress myocardial scintigraphy was performed in convalescent patients with acute myocardial infarction, to evaluate the influence of stenosis and collateral circulation of coronary artery in acute phase, on myocardial salvage in chronic phase. In 14 cases of unsuccessful coronary revascularization (complete occlusion), a complete defect of thallium imaging in chronic phase was seen in only one case of four cases with good collateral circulation, while eight of 10 cases with poor collateral circulation. In 16 cases with collateral circulation, six cases showed a complete defect, although the target vessel had improved to less than 75% of stenosis. However, in cases of good collateral circulation, no case showed a complete defect when the target vessel had improved to less than 75% of stenosis. The myocardial salvage is quite possible (p<0.05), when the coronary angiography in acute phase showed the forward flow (99% or 90% of stenosis) before coronary revascularization and/or good collateral circulation (Rentrop 2deg or 3deg). (author)

  11. High-resolution mapping of forest carbon stocks in the Colombian Amazon

    Directory of Open Access Journals (Sweden)

    G. P. Asner

    2012-07-01

    Full Text Available High-resolution mapping of tropical forest carbon stocks can assist forest management and improve implementation of large-scale carbon retention and enhancement programs. Previous high-resolution approaches have relied on field plot and/or light detection and ranging (LiDAR samples of aboveground carbon density, which are typically upscaled to larger geographic areas using stratification maps. Such efforts often rely on detailed vegetation maps to stratify the region for sampling, but existing tropical forest maps are often too coarse and field plots too sparse for high-resolution carbon assessments. We developed a top-down approach for high-resolution carbon mapping in a 16.5 million ha region (> 40% of the Colombian Amazon – a remote landscape seldom documented. We report on three advances for large-scale carbon mapping: (i employing a universal approach to airborne LiDAR-calibration with limited field data; (ii quantifying environmental controls over carbon densities; and (iii developing stratification- and regression-based approaches for scaling up to regions outside of LiDAR coverage. We found that carbon stocks are predicted by a combination of satellite-derived elevation, fractional canopy cover and terrain ruggedness, allowing upscaling of the LiDAR samples to the full 16.5 million ha region. LiDAR-derived carbon maps have 14% uncertainty at 1 ha resolution, and the regional map based on stratification has 28% uncertainty in any given hectare. High-resolution approaches with quantifiable pixel-scale uncertainties will provide the most confidence for monitoring changes in tropical forest carbon stocks. Improved confidence will allow resource managers and decision makers to more rapidly and effectively implement actions that better conserve and utilize forests in tropical regions.

  12. The implementation of sea ice model on a regional high-resolution scale

    Science.gov (United States)

    Prasad, Siva; Zakharov, Igor; Bobby, Pradeep; McGuire, Peter

    2015-09-01

    The availability of high-resolution atmospheric/ocean forecast models, satellite data and access to high-performance computing clusters have provided capability to build high-resolution models for regional ice condition simulation. The paper describes the implementation of the Los Alamos sea ice model (CICE) on a regional scale at high resolution. The advantage of the model is its ability to include oceanographic parameters (e.g., currents) to provide accurate results. The sea ice simulation was performed over Baffin Bay and the Labrador Sea to retrieve important parameters such as ice concentration, thickness, ridging, and drift. Two different forcing models, one with low resolution and another with a high resolution, were used for the estimation of sensitivity of model results. Sea ice behavior over 7 years was simulated to analyze ice formation, melting, and conditions in the region. Validation was based on comparing model results with remote sensing data. The simulated ice concentration correlated well with Advanced Microwave Scanning Radiometer for EOS (AMSR-E) and Ocean and Sea Ice Satellite Application Facility (OSI-SAF) data. Visual comparison of ice thickness trends estimated from the Soil Moisture and Ocean Salinity satellite (SMOS) agreed with the simulation for year 2010-2011.

  13. Performance of a high resolution cavity beam position monitor system

    Science.gov (United States)

    Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Pete; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Honda, Yosuke; Kolomensky, Yury; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; Thomson, Mark; Urakawa, Junji; Vogel, Vladimir; Ward, David; White, Glen

    2007-07-01

    It has been estimated that an RF cavity Beam Position Monitor (BPM) could provide a position measurement resolution of less than 1 nm. We have developed a high resolution cavity BPM and associated electronics. A triplet comprised of these BPMs was installed in the extraction line of the Accelerator Test Facility (ATF) at the High Energy Accelerator Research Organization (KEK) for testing with its ultra-low emittance beam. The three BPMs were each rigidly mounted inside an alignment frame on six variable-length struts which could be used to move the BPMs in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, we have demonstrated a position resolution of 15.6 nm and a tilt resolution of 2.1 μrad over a dynamic range of approximately ±20 μm.

  14. The high resolution shear wave seismic reflection technique

    International Nuclear Information System (INIS)

    Johnson, W.J.; Clark, J.C.

    1991-04-01

    This report presents the state-of-the-art of the high resolution S-wave reflection technique. Published and unpublished literature has been reviewed and discussions have been held with experts. Result is to confirm that the proposed theoretical and practical basis for identifying aquifer systems using both P- and S-wave reflections is sound. Knowledge of S-wave velocity and P-wave velocity is a powerful tool for assessing the fluid characteristics of subsurface layers. Material properties and lateral changes in material properties such as change from clay to sand, can be inferred from careful dual evaluation of P and S-wave records. The high resolution S-wave reflection technique has seen its greatest application to date as part of geotechnical studies for building foundations in the Far East. Information from this type of study has been evaluated and will be incorporated in field studies. In particular, useful information regarding S-wave sources, noise suppression and recording procedures will be incorporated within the field studies. Case histories indicate that the best type of site for demonstrating the power of the high resolution S-wave technique will be in unconsolidated soil without excessive structural complexities. More complex sites can form the basis for subsequent research after the basic principles of the technique can be established under relatively uncomplicated conditions

  15. Characteristics of 201Tl myocardial SPECT and left ventriculography in patients with acute diagonal branch myocardial infarction

    International Nuclear Information System (INIS)

    Tanaka, Takeshi; Aizawa, Tadanori; Katou, Kazuzo; Ogasawara, Ken; Kirigaya, Hajime

    1993-01-01

    Characteristics of 201 Tl myocardial SPECT and ventriculography were studied in 13 patients with acute diagonal branch myocardial infarction. Rest 201 Tl myocardial SPECT and left ventriculography were underwent in chronic phase. In 5 patients electrocardiogram (ECG) changes in acute phase were not definite. In 6 patients it was difficult to identify the obstructed coronary artery with coronary angiography in acute phase. Mean value of maximum creatine phosphokinese (CPK) was 854 (458-1,774) U/l. It seemed to be difficult to diagnose acute diagonal branch myocardial infarction with ECG and/or coronary angiography. In all patients defects were noted on 201 Tl SPECT. Defects were small and noted in the central anterior wall and not in the septum. In 2 patients defects were noted at apex. In left ventriculography dyskinetic motion was noted in 10 patients; one patient showed apical aneurysm and 3 patients showed anterior wall aneurysm. In 3 patients anterior wall showed akinesis. It was concluded that 201 Tl myocardial SPECT were useful for detecting diagonal branch lesion. In case of diagonal branch myocardial infarction size of defects were small and defects were not noted in the septum, however aneurysmal motion was frequently noted. (author)

  16. Amphetamine Containing Dietary Supplements and Acute Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Julio Perez-Downes

    2016-01-01

    Full Text Available Weight loss is one of the most researched and marketed topics in American society. Dietary regimens, medications that claim to boost the metabolism, and the constant pressure to fit into society all play a role in our patient’s choices regarding new dietary products. One of the products that are well known to suppress appetite and cause weight loss is amphetamines. While these medications suppress appetite, most people are not aware of the detrimental side effects of amphetamines, including hypertension, tachycardia, arrhythmias, and in certain instances acute myocardial infarction. Here we present the uncommon entity of an acute myocardial infarction due to chronic use of an amphetamine containing dietary supplement in conjunction with an exercise regimen. Our case brings to light further awareness regarding use of amphetamines. Clinicians should have a high index of suspicion of use of these substances when young patients with no risk factors for coronary artery disease present with acute arrhythmias, heart failure, and myocardial infarctions.

  17. Charge-coupled devices for particle detection with high spatial resolution

    International Nuclear Information System (INIS)

    Farley, F.J.; Damerell, C.J.S.; Gillman, A.R.; Wickens, F.J.

    1980-10-01

    The results of a study of the possible application of a thin microelectronic device (the charge-coupled device) to high energy physics as particle detectors with good spatial resolution which can distinguish between tracks emerging from the primary vertex and those from secondary vertices due to the decay of short lived particles with higher flavours, are reported. Performance characteristics indicating the spatial resolution, particle discrimination, time resolution, readout time and lifetime of such detectors have been obtained. (U.K.)

  18. Rapid calibrated high-resolution hyperspectral imaging using tunable laser source

    Science.gov (United States)

    Nguyen, Lam K.; Margalith, Eli

    2009-05-01

    We present a novel hyperspectral imaging technique based on tunable laser technology. By replacing the broadband source and tunable filters of a typical NIR imaging instrument, several advantages are realized, including: high spectral resolution, highly variable field-of-views, fast scan-rates, high signal-to-noise ratio, and the ability to use optical fiber for efficient and flexible sample illumination. With this technique, high-resolution, calibrated hyperspectral images over the NIR range can be acquired in seconds. The performance of system features will be demonstrated on two example applications: detecting melamine contamination in wheat gluten and separating bovine protein from wheat protein in cattle feed.

  19. Myocardial scintigraphy with /sup 201/Tl and quantitative assessment of myocardial blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Y; Kanbara, H; Yonekura, Y; Kadota, K; Fujita, T [Kyoto Univ. (Japan). Faculty of Medicine

    1976-12-01

    A newly introduced radionuclide for myocardial imaging, /sup 201/Tl, was studied. Twenty-two subjects consisting of 7 normals, 12 with ischemic heart disease and 3 with hypertrophic cardiomyopathy (HCM) were selected. On intravenous administration of /sup 201/Tl(1.5 to 20. mCi), initial transit of the tracer through the heart, as well as subsequent uptake by the myocardium, were recorded by a scintillation camera. The later process showed the distribution of the myocardial blood flow (MBF). A normal myocardial scintigraphy revealed the left-sided myocardial mass predominantly, whereas the right side or the septum predominated in the case of tetralogy of fallot (T/F) or idiopathic hypertrophic subuaortic stenosis (IHSS). An ischemic or infarcted area of the myocardium in ischemic heart disease (IHD) was compatible with electrocardiographic findings, and revealed defects even in an equivocal case on ECG. Since the ratio of radioactivity taken up by the myocardium (U) to the total injected dosis (I) is assumed to be proportional to the fractional MBF of cardiac output (CO), MBF/CO is calculated by ratio of the radioactivity selected from myocardial region on the later recording to that from the entire region on the initial transit of the tracer bolus. The average MBF/CO of normals was 4.4 +- 0.5%, IHD 4.0 +- 0.8% and HCM 5.5 +- 1.2%. On exercise loading, a significant increase of this value was observed in normals, whereas no change was observed in IHD.

  20. High Resolution Higher Energy X-ray Microscope for Mesoscopic Materials

    International Nuclear Information System (INIS)

    Snigireva, I; Snigirev, A

    2013-01-01

    We developed a novel X-ray microscopy technique to study mesoscopically structured materials, employing compound refractive lenses. The easily seen advantage of lens-based methodology is the possibility to retrieve high resolution diffraction pattern and real-space images in the same experimental setup. Methodologically the proposed approach is similar to the studies of crystals by high resolution transmission electron microscopy. The proposed microscope was applied for studying of mesoscopic materials such as natural and synthetic opals, inverted photonic crystals

  1. Frequency of myocardial injury after blunt chest trauma as evaluated by radionuclide angiography

    International Nuclear Information System (INIS)

    Sutherland, G.R.; Driedger, A.A.; Holliday, R.L.; Cheung, H.W.; Sibbald, W.J.

    1983-01-01

    Seventy-seven patients who had sustained multisystem trauma, including severe blunt chest injury, were prospectively evaluated to assess the frequency of associated traumatic myocardial injury. Traumatic injury to either the right or left ventricle was defined by the presence of discrete abnormalities of wall motion on electrocardiographically gated cardiac scintigraphy in patients without a clinical history of heart disease. Forty-two patients (55%) (Group 1) had focal abnormalities of wall motion; 27 involved the right ventricle, 7 the left ventricle, 7 were biventricular, and 1 involved only the septum. Both the right and left ventricular ejection fractions were significantly lower (31 +/- 11% and 47 +/- 14%, respectively) than those in the 35 traumatized patients without wall motion abnormalities on scintigraphy (Group 2) (49 +/- 8% and 58 +/- 11%, respectively). Repeat scintigraphic examination in 32 Group 1 patients at a time remote from initial injury showed improvement or resolution of previously defined focal wall motion abnormalities in 27 of 32 patients (84%). The electrocardiogram and serum enzyme tests were insensitive indexes of traumatic myocardial injury when defined by the scintigraphic abnormalities. Thus, severe blunt chest trauma results in a higher frequency of traumatic myocardial injury than heretofore recognized, and frequently involves the anteriorly situated right ventricle

  2. High-degree atrioventricular block complicating ST-segment elevation myocardial infarction in the era of primary percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Gang, Uffe Jakob Ortved; Hvelplund, Anders; Pedersen, Sune

    2012-01-01

    Primary percutaneous coronary intervention (pPCI) has replaced thrombolysis as treatment-of-choice for ST-segment elevation myocardial infarction (STEMI). However, the incidence and prognostic significance of high-degree atrioventricular block (HAVB) in STEMI patients in the pPCI era has been only...... sparsely investigated. The objective of this study was to assess the incidence, predictors and prognostic significance of HAVB in STEMI patients treated with pPCI....

  3. Solutions on high-resolution multiple configuration system sensors

    Science.gov (United States)

    Liu, Hua; Ding, Quanxin; Guo, Chunjie; Zhou, Liwei

    2014-11-01

    For aim to achieve an improved resolution in modern image domain, a method of continuous zoom multiple configuration, with a core optics is attempt to establish model by novel principle on energy transfer and high accuracy localization, by which the system resolution can be improved with a level in nano meters. A comparative study on traditional vs modern methods can demonstrate that the dialectical relationship and their balance is important, among Merit function, Optimization algorithms and Model parameterization. The effect of system evaluated criterion that MTF, REA, RMS etc. can support our arguments qualitatively.

  4. Development of high-energy resolution inverse photoemission technique

    International Nuclear Information System (INIS)

    Asakura, D.; Fujii, Y.; Mizokawa, T.

    2005-01-01

    We developed a new inverse photoemission (IPES) machine based on a new idea to improve the energy resolution: off-plane Eagle mounting of the optical system in combination with dispersion matching between incoming electron and outgoing photon. In order to achieve dispersion matching, we have employed a parallel plate electron source and have investigated whether the electron beam is obtained as expected. In this paper, we present the principle and design of the new IPES method and report the current status of the high-energy resolution IPES machine

  5. High-Resolution Reciprocal Space Mapping for Characterizing Deformation Structures

    DEFF Research Database (Denmark)

    Pantleon, Wolfgang; Wejdemann, Christian; Jakobsen, Bo

    2014-01-01

    With high-angular resolution three-dimensional X-ray diffraction (3DXRD), quantitative information is gained about dislocation structures in individual grains in the bulk of a macroscopic specimen by acquiring reciprocal space maps. In high-resolution 3D reciprocal space maps of tensile......-deformed copper, individual, almost dislocation-free subgrains are identified from high-intensity peaks and distinguished by their unique combination of orientation and elastic strain; dislocation walls manifest themselves as a smooth cloud of lower intensity. The elastic strain shows only minor variations within...... dynamics is followed in situ during varying loading conditions by reciprocal space mapping: during uninterrupted tensile deformation, formation of subgrains is observed concurrently with broadening of Bragg reflections shortly after the onset of plastic deformation. When the traction is terminated, stress...

  6. Self-triggered image intensifier tube for high-resolution UHECR imaging detector

    CERN Document Server

    Sasaki, M; Jobashi, M

    2003-01-01

    The authors have developed a self-triggered image intensifier tube with high-resolution imaging capability. An image detected by a first image intensifier tube as an electrostatic lens with a photocathode diameter of 100 mm is separated by a half-mirror into a path for CCD readout (768x494 pixels) and a fast control to recognize and trigger the image. The proposed system provides both a high signal-to-noise ratio to improve single photoelectron detection and excellent spatial resolution between 207 and 240 mu m rendering this device a potentially essential tool for high-energy physics and astrophysics experiments, as well as high-speed photography. When combined with a 1-arcmin resolution optical system with 50 deg. field-of-view proposed by the present authors, the observation of ultra high-energy cosmic rays and high-energy neutrinos using this device is expected, leading to revolutionary progress in particle astrophysics as a complementary technique to traditional astronomical observations at multiple wave...

  7. High spectral resolution X-ray observations of AGN

    NARCIS (Netherlands)

    Kaastra, J.S.

    2008-01-01

    brief overview of some highlights of high spectral resolution X-ray observations of AGN is given, mainly obtained with the RGS of XMM-Newton. Future prospects for such observations with XMM-Newton are given.

  8. [Diagnostics of acute myocardial infarction in elderly patients].

    Science.gov (United States)

    Bahrmann, P; Heppner, H J; Bahrmann, A; Christ, M; Bertsch, T; Sieber, C C

    2011-06-01

    The early diagnosis of an acute myocardial infarction (MI) is improved by the introduction of novel high-sensitivity troponin assays. These assays can measure low level myocardial injury not detectable by standard troponin assays. Especially in older patients who appear to have a higher basal troponin level, the results must always be judged in the context of the medical history, physical examination, electrocardiogram (ECG) and any further findings. Even small increases in high-sensitivity troponin indicate increased risk for death or MI during follow-up. In the case of MI an invasive strategy results in better survival rates compared with conservative therapy but at the expense of an increased risk of bleeding in elderly patients. This article provides an overview on the diagnosis of MI in elderly patients.

  9. A high resolution 16 k multi-channel analyzer PC add-on card

    International Nuclear Information System (INIS)

    Kulkarni, C.P.; Paulson, Molly; Vaidya, P.P.

    2001-01-01

    This paper describes the system details of a 16 K channel resolution Multi-Channel Analyzer (MCA) developed at Electronics Division, BARC, which is used in high resolution nuclear spectroscopy systems for pulse height analysis. The high resolution data acquisition PC add-on card is architectured using a state of the art digital circuit design technology which makes use of a Field Programmable Gate Array (FPGA), and some of the most modern and advanced analog counterparts like low power, high speed and high precision comparators, Op-amps, ADCs and DACs etc. The 16 K MCA card gives an economic, compact, and low power alternative for nuclear pulse spectroscopy use. (author)

  10. An angle encoder for super-high resolution and super-high accuracy using SelfA

    International Nuclear Information System (INIS)

    Watanabe, Tsukasa; Kon, Masahito; Nabeshima, Nobuo; Taniguchi, Kayoko

    2014-01-01

    Angular measurement technology at high resolution for applications such as in hard disk drive manufacturing machines, precision measurement equipment and aspherical process machines requires a rotary encoder with high accuracy, high resolution and high response speed. However, a rotary encoder has angular deviation factors during operation due to scale error or installation error. It has been assumed to be impossible to achieve accuracy below 0.1″ in angular measurement or control after the installation onto the rotating axis. Self-calibration (Lu and Trumper 2007 CIRP Ann. 56 499; Kim et al 2011 Proc. MacroScale; Probst 2008 Meas. Sci. Technol. 19 015101; Probst et al Meas. Sci. Technol. 9 1059; Tadashi and Makoto 1993 J. Robot. Mechatronics 5 448; Ralf et al 2006 Meas. Sci. Technol. 17 2811) and cross-calibration (Probst et al 1998 Meas. Sci. Technol. 9 1059; Just et al 2009 Precis. Eng. 33 530; Burnashev 2013 Quantum Electron. 43 130) technologies for a rotary encoder have been actively discussed on the basis of the principle of circular closure. This discussion prompted the development of rotary tables which achieve reliable and high accuracy angular verification. We apply these technologies for the development of a rotary encoder not only to meet the requirement of super-high accuracy but also to meet that of super-high resolution. This paper presents the development of an encoder with 2 21 = 2097 152 resolutions per rotation (360°), that is, corresponding to a 0.62″ signal period, achieved by the combination of a laser rotary encoder supplied by Magnescale Co., Ltd and a self-calibratable encoder (SelfA) supplied by The National Institute of Advanced Industrial Science and Technology (AIST). In addition, this paper introduces the development of a rotary encoder to guarantee ±0.03″ accuracy at any point of the interpolated signal, with respect to the encoder at the minimum resolution of 2 33 , that is, corresponding to a 0.0015″ signal period

  11. Assessment of prediction skill in equatorial Pacific Ocean in high resolution model of CFS

    Science.gov (United States)

    Arora, Anika; Rao, Suryachandra A.; Pillai, Prasanth; Dhakate, Ashish; Salunke, Kiran; Srivastava, Ankur

    2018-01-01

    The effect of increasing atmospheric resolution on prediction skill of El Niño southern oscillation phenomenon in climate forecast system model is explored in this paper. Improvement in prediction skill for sea surface temperature (SST) and winds at all leads compared to low resolution model in the tropical Indo-Pacific basin is observed. High resolution model is able to capture extreme events reasonably well. As a result, the signal to noise ratio is improved in the high resolution model. However, spring predictability barrier (SPB) for summer months in Nino 3 and Nino 3.4 region is stronger in high resolution model, in spite of improvement in overall prediction skill and dynamics everywhere else. Anomaly correlation coefficient of SST in high resolution model with observations in Nino 3.4 region targeting boreal summer months when predicted at lead times of 3-8 months in advance decreased compared its lower resolution counterpart. It is noted that higher variance of winds predicted in spring season over central equatorial Pacific compared to observed variance of winds results in stronger than normal response on subsurface ocean, hence increases SPB for boreal summer months in high resolution model.

  12. Diagnosis of acute myocardial infarction in patients undergoing open heart surgery: a comparison of serial myocardial imaging with cardiac enzymes, electrocardiography, and vectocardiography

    International Nuclear Information System (INIS)

    Lowenthal, I.S.; Parisi, A.F.; Tow, D.E.; Barsamian, E.M.; Sasahara, A.A.; McCaughan, D.; Clemson, H.C.

    1977-01-01

    In 44 consecutive patients undergoing elective open heart surgery (OHS), serial electrocardiograms (ECG), vectorcardiograms (VCG), serum CPK, cardiac isoenzymes (CPKMB), and myocardial images using Tc-99m pyrophosphate were obtained, before and after the operation, for the detection of acute myocardial infarction (AMI). Twenty-nine patients developed one or more positive tests postoperatively. Two patients had positive myocardial scintiscans; both had other evidence of infarction. Conversely, the appearance of CPKMB, or new ECG and VCG changes, occurred frequently without evidence of infarction, and were not associated with the development of a positive scintiscan. The results show that false-negative results are infrequent in patients imaged early after OHS, and that cardiac surgical procedures do not cause a high incidence of false-positive scintigrams. Consequently, radionuclide imaging for AMI offers an important adjunct for excluding acute infarction following open heart surgery

  13. High-Resolution Near Real-Time Drought Monitoring in South Asia

    Science.gov (United States)

    Aadhar, S.; Mishra, V.

    2017-12-01

    Drought in South Asia affect food and water security and pose challenges for millions of people. For policy-making, planning and management of water resources at the sub-basin or administrative levels, high-resolution datasets of precipitation and air temperature are required in near-real time. Here we develop a high resolution (0.05 degree) bias-corrected precipitation and temperature data that can be used to monitor near real-time drought conditions over South Asia. Moreover, the dataset can be used to monitor climatic extremes (heat waves, cold waves, dry and wet anomalies) in South Asia. A distribution mapping method was applied to correct bias in precipitation and air temperature (maximum and minimum), which performed well compared to the other bias correction method based on linear scaling. Bias-corrected precipitation and temperature data were used to estimate Standardized precipitation index (SPI) and Standardized Precipitation Evapotranspiration Index (SPEI) to assess the historical and current drought conditions in South Asia. We evaluated drought severity and extent against the satellite-based Normalized Difference Vegetation Index (NDVI) anomalies and satellite-driven Drought Severity Index (DSI) at 0.05˚. We find that the bias-corrected high-resolution data can effectively capture observed drought conditions as shown by the satellite-based drought estimates. High resolution near real-time dataset can provide valuable information for decision-making at district and sub- basin levels.

  14. New detector developments for high resolution positron emission tomography

    International Nuclear Information System (INIS)

    Ziegler, S.I.; Pichler, B.; Lorenz, E.

    1998-01-01

    The strength of quantitative, functional imaging using positron emission tomography, specially in small animals, is limited due to the spatial resolution. Therefore, various tomograph designs employing new scintillators, light sensors, or coincidence electronic are investigated to improve resolution without losses in sensitivity. Luminous scintillators with short light decay time in combination with novel readout schemes using photomultipliers or semiconductor detectors are currently tested by several groups and are implemented in tomographs for small animals. This review summarises the state of development in high resolution positron emission tomography with a detailed description of a system incorporating avalanche photodiode arrays and small scintillation crystals. (orig.) [de

  15. High Resolution Thz and FIR Spectroscopy of SOCl_2

    Science.gov (United States)

    Martin-Drumel, M. A.; Cuisset, A.; Sadovskii, D. A.; Mouret, G.; Hindle, F.; Pirali, O.

    2013-06-01

    Thionyl chloride (SOCl_2) is an extremely powerful oxidant widely used in industrial processes and playing a role in the chemistry of the atmosphere. In addition, it has a molecular configuration similar to that of phosgene (COCl_2), and is therefore of particular interest for security and defense applications. Low resolution vibrational spectra of gas phase SOCl_2 as well as high resolution pure rotational transitions up to 25 GHz have previously been investigated. To date no high resolution data are reported at frequencies higher than 25 GHz. We have investigated the THz absorption spectrum of SOCl_2 in the spectral region 70-650 GHz using a frequency multiplier chain coupled to a 1 m long single path cell containing a pressure of about 15 μbar. At the time of the writing, about 8000 pure rotational transitions of SO^{35}Cl_2 with highest J and K_a values of 110 and 50 respectively have been assigned on the spectrum. We have also recorded the high resolution FIR spectra of SOCl_2 in the spectral range 50-700 wn using synchrotron radiation at the AILES beamline of SOLEIL facility. A White-type cell aligned with an absorption path length of 150 m has been used to record, at a resolution of 0.001 wn, two spectra at pressures of 5 and 56 μbar of SOCl_2. On these spectra all FIR modes of SOCl_2 are observed (ν_2 to ν_6) and present a resolved rotational structure. Their analysis is in progress. T. J. Johnson et al., J. Phys. Chem. A 107, 6183 (2003) D. E. Martz and R. T. Lagemann, J. Chem. Phys. 22,1193 (1954) H. S. P. Müller and M. C. L. Gerry, J. Chem. Soc. Faraday Trans. 90, 3473 (1994)

  16. A high resolution large dynamic range TDC circuit implementation

    International Nuclear Information System (INIS)

    Lei Wuhu; Liu Songqiu; Ye Weiguo; Han Hui; Li Pengyu

    2003-01-01

    Time measurement technology is usually used in nuclear experimentation. There are many methods of time measurement. The implementation method of Time to Digital Conversion (TDC) by means of electronic is a classical technology. The range and resolution of TDC is different according with different usage. A wide range and high resolution TDC circuit, including its theory and implementation way, is introduced in this paper. The test result is also given. (authors)

  17. A high resolution large dynamic range TDC circuit implementation

    International Nuclear Information System (INIS)

    Lei Wuhu; Liu Songqiu; Li Pengyu; Han Hui; Ye Yanlin

    2005-01-01

    Time measurement technology is usually used in nuclear experimentation. There are many methods of time measurement. The implementation method of Time to Digital Conversion (TDC) by means of electronics is a classical technology. The range and resolution of TDC is different according with different usage. A wide range and high resolution TDC circuit, including its theory and implementation way, is introduced in this paper. The test result is also given. (authors)

  18. High-resolution retinal imaging using adaptive optics and Fourier-domain optical coherence tomography

    Science.gov (United States)

    Olivier, Scot S.; Werner, John S.; Zawadzki, Robert J.; Laut, Sophie P.; Jones, Steven M.

    2010-09-07

    This invention permits retinal images to be acquired at high speed and with unprecedented resolution in three dimensions (4.times.4.times.6 .mu.m). The instrument achieves high lateral resolution by using adaptive optics to correct optical aberrations of the human eye in real time. High axial resolution and high speed are made possible by the use of Fourier-domain optical coherence tomography. Using this system, we have demonstrated the ability to image microscopic blood vessels and the cone photoreceptor mosaic.

  19. High-heat tank safety issue resolution program plan

    International Nuclear Information System (INIS)

    Wang, O.S.

    1993-12-01

    The purpose of this program plan is to provide a guide for selecting corrective actions that will mitigate and/or remediate the high-heat waste tank safety issue for single-shell tank (SST) 241-C-106. This program plan also outlines the logic for selecting approaches and tasks to mitigate and resolve the high-heat safety issue. The identified safety issue for high-heat tank 241-C-106 involves the potential release of nuclear waste to the environment as the result of heat-induced structural damage to the tank's concrete, if forced cooling is interrupted for extended periods. Currently, forced ventilation with added water to promote thermal conductivity and evaporation cooling is used to cool the waste. At this time, the only viable solution identified to resolve this safety issue is the removal of heat generating waste in the tank. This solution is being aggressively pursued as the permanent solution to this safety issue and also to support the present waste retrieval plan. Tank 241-C-106 has been selected as the first SST for retrieval. The program plan has three parts. The first part establishes program objectives and defines safety issues, drivers, and resolution criteria and strategy. The second part evaluates the high-heat safety issue and its mitigation and remediation methods and alternatives according to resolution logic. The third part identifies major tasks and alternatives for mitigation and resolution of the safety issue. Selected tasks and best-estimate schedules are also summarized in the program plan

  20. Morphological aspects of myocardial bridges.

    Science.gov (United States)

    Lujinović, Almira; Kulenović, Amela; Kapur, Eldan; Gojak, Refet

    2013-11-01

    Although some myocardial bridges can be asymptomatic, their presence often causes coronary disease either through direct compression of the "tunnel" segment or through stimulation and accelerated development of atherosclerosis in the segment proximally to the myocardial bridge. The studied material contained 30 human hearts received from the Department of Anatomy. The hearts were preserved 3 to 5 days in 10% formalin solution. Thereafter, the fatty tissue was removed and arterial blood vessels prepared by careful dissection with special reference to the presence of the myocardial bridges. Length and thickness of the bridges were measured by the precise electronic caliper. The angle between the myocardial bridge fibre axis and other axis of the crossed blood vessel was measured by a goniometer. The presence of the bridges was confirmed in 53.33% of the researched material, most frequently (43.33%) above the anterior interventricular branch. The mean length of the bridges was 14.64 ± 9.03 mm and the mean thickness was 1.23 ± 1.32 mm. Myocardial bridge fibres pass over the descending blood vessel at the angle of 10-90 degrees. The results obtained on a limited sample suggest that the muscular index of myocardial bridge is the highest for bridges located on RIA, but that the difference is not significant in relation to bridges located on other branches. The results obtained suggest that bridges located on other branches, not only those on RIA, could have a great contractive power and, consequently, a great compressive force, which would be exerted on the wall of a crossed blood vessel.

  1. Mastering high resolution tip-enhanced Raman spectroscopy: towards a shift of perception.

    Science.gov (United States)

    Richard-Lacroix, Marie; Zhang, Yao; Dong, Zhenchao; Deckert, Volker

    2017-07-03

    Recent years have seen tremendous improvement of our understanding of high resolution reachable in TERS experiments, forcing us to re-evaluate our understanding of the intrinsic limits of this field, but also exposing several inconsistencies. On the one hand, more and more recent experimental results have provided us with clear indications of spatial resolutions down to a few nanometres or even on the subnanometre scale. Moreover, lessons learned from recent theoretical investigations clearly support such high resolutions, and vice versa the obvious theoretical impossibility to evade high resolution from a purely plasmonic point of view. On the other hand, most of the published TERS results still, to date, claim a resolution on the order of tens of nanometres that would be somehow limited by the tip apex, a statement well accepted for the past 2 decades. Overall, this now leads the field to a fundamental question: how can this divergence be justified? The answer to this question brings up an equally critical one: how can this gap be bridged? This review aims at raising a fundamental discussion related to the resolution limits of tip-enhanced Raman spectroscopy, at revisiting our comprehension of the factors limiting it both from a theoretical and an experimental point of view and at providing indications on how to move the field ahead. It is our belief that a much deeper understanding of the real accessible lateral resolution in TERS and the practical factors that limit them will simultaneously help us to fully explore the potential of this technique for studying nanoscale features in organic, inorganic and biological systems, and also to improve both the reproducibility and the accuracy of routine TERS studies. A significant improvement of our comprehension of the accessible resolution in TERS is thus critical for a broad audience, even in certain contexts where high resolution TERS is not the desired outcome.

  2. Elevated plasma procalcitonin level predicts poor prognosis of ST elevation myocardial infarction in Asian elderly.

    Science.gov (United States)

    Dai, Junru; Xia, Bangbo; Wu, Xiaomiao

    Previous studies have focused on relationship between plasma procalcitonin level and myocardial infarction risk, but this relationship in Asian elderly has not been investigated. The aim of this study was to reveal the association of peripheral procalcitonin concentration (both immediate and average levels) with myocardial infarction prognosis in Asian elderly. A total of 400 ST-elevation myocardial infarction patients, 400 unstable angina patients and 400 controls were included. Plasma levels of high-sensitivity C-reactive protein and procalcitonin were measured using commercially available kits. Each myocardial infarction patient received a standard therapy and a 12-month follow-up unless major adverse cardiac events occurred. On admission, plasma procalcitonin level was higher in myocardial infarction patients than in unstable angina patients and controls (p < .001). In the follow-up period, 142 myocardial infarction patients suffered from major adverse cardiac events, and other 258 myocardial infarction patients did not. Higher admission, peak and average plasma levels of procalcitonin in the first week after chest pain onset were associated with elevated risk of major adverse cardiac events (HR: 1.46, 95%CI: 1.18-1.99; HR: 2.57, 95%CI: 1.99-3.52; HR: 2.36, 95%CI: 1.81-3.00). Plasma procalcitonin level had a positive linear correlation with plasma level of high-sensitivity C-reactive protein on admission (r = 0.650, p < .001). In conclusion, peripheral concentration of procalcitonin (both immediate and average levels) might be an independent predictor for prognosis in myocardial infarction patients. Prognostic significance of procalcitonin might be implicated in inflammation.

  3. High resolution, position sensitive detector for energetic particle beams

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, E P [Charles Evans and Associates, Redwood City, CA (United States); Strathman, M D [Charles Evans and Associates, Redwood City, CA (United States); Reed, D A [Charles Evans and Associates, Redwood City, CA (United States); Odom, R W [Charles Evans and Associates, Redwood City, CA (United States); Morse, D H [Sandia National Labs., Livermore, CA (United States); Pontau, A E [Sandia National Labs., Livermore, CA (United States)

    1993-05-01

    The performance and design of an imaging position sensitive, particle beam detector will be presented. The detector is minimally invasive, operates a wide dynamic range (>10[sup 10]), and exhibits high spatial resolution. The secondary electrons produced when a particle beam passes through a thin foil are imaged using stigmatic ion optics onto a two-dimensional imaging detector. Due to the low scattering cross section of the 6 nm carbon foil the detector is a minimal perturbation on the primary beam. A prototype detector with an image resolution of approximately 5 [mu]m for a field of view of 1 mm has been reported. A higher resolution detector for imaging small beams (<50 [mu]m) with an image resolution of better than 0.5 [mu]m has since been developed and its design is presented. (orig.)

  4. WRF high resolution dynamical downscaling of ERA-Interim for Portugal

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Pedro M.M. [University of Lisbon, Instituto Dom Luiz, Lisbon (Portugal); Faculdade de Ciencias da Universidade de Lisboa, Lisbon (Portugal); Cardoso, Rita M.; Miranda, Pedro M.A.; Medeiros, Joana de [University of Lisbon, Instituto Dom Luiz, Lisbon (Portugal); Belo-Pereira, Margarida; Espirito-Santo, Fatima [Instituto de Meteorologia, Lisbon (Portugal)

    2012-11-15

    This study proposes a dynamically downscaled climatology of Portugal, produced by a high resolution (9 km) WRF simulation, forced by 20 years of ERA-Interim reanalysis (1989-2008), nested in an intermediate domain with 27 km of resolution. The Portuguese mainland is characterized by large precipitation gradients, with observed mean annual precipitation ranging from about 400 to over 2,200 mm, with a very wet northwest and rather dry southeast, largely explained by orographic processes. Model results are compared with all available stations with continuous records, comprising daily information in 32 stations for temperature and 308 for precipitation, through the computation of mean climatologies, standard statistical errors on daily to seasonally timescales, and distributions of extreme events. Results show that WRF at 9 km outperforms ERA-Interim in all analyzed variables, with good results in the representation of the annual cycles in each region. The biases of minimum and maximum temperature are reduced, with improvement of the description of temperature variability at the extreme range of its distribution. The largest gain of the high resolution simulations is visible in the rainiest regions of Portugal, where orographic enhancement is crucial. These improvements are striking in the high ranking percentiles in all seasons, describing extreme precipitation events. WRF results at 9 km compare favorably with published results supporting its use as a high-resolution regional climate model. This higher resolution allows a better representation of extreme events that are of major importance to develop mitigation/adaptation strategies by policy makers and downstream users of regional climate models in applications such as flash floods or heat waves. (orig.)

  5. Regional Longitudinal Myocardial Deformation Provides Incremental Prognostic Information in Patients with ST-Segment Elevation Myocardial Infarction.

    Directory of Open Access Journals (Sweden)

    Tor Biering-Sørensen

    Full Text Available Global longitudinal systolic strain (GLS has recently been demonstrated to be a superior prognosticator to conventional echocardiographic measures in patients after myocardial infarction (MI. The aim of this study was to evaluate the prognostic value of regional longitudinal myocardial deformation in comparison to GLS, conventional echocardiography and clinical information.In total 391 patients were admitted with ST-Segment elevation myocardial infarction (STEMI, treated with primary percutaneous coronary intervention and subsequently examined by echocardiography. All patients were examined by tissue Doppler imaging (TDI and two-dimensional strain echocardiography (2DSE.During a median-follow-up of 5.3 (IQR 2.5-6.1 years the primary endpoint (death, heart failure or a new MI was reached by 145 (38.9% patients. After adjustment for significant confounders (including conventional echocardiographic parameters and culprit lesion, reduced longitudinal performance in the anterior septal and inferior myocardial regions (but not GLS remained independent predictors of the combined outcome. Furthermore, inferior myocardial longitudinal deformation provided incremental prognostic information to clinical and conventional echocardiographic information (Harrell's c-statistics: 0.63 vs. 0.67, p = 0.032. In addition, impaired longitudinal deformation outside the culprit lesion perfusion region was significantly associated with an adverse outcome (p<0.05 for all deformation parameters.Regional longitudinal myocardial deformation measures, regardless if determined by TDI or 2DSE, are superior prognosticators to GLS. In addition, impaired longitudinal deformation in the inferior myocardial segment provides prognostic information over and above clinical and conventional echocardiographic risk factors. Furthermore, impaired longitudinal deformation outside the culprit lesion perfusion region seems to be a paramount marker of adverse outcome.

  6. ST segment elevation after myocardial infarction: Viability or ventricular dysfunction? Comparison with myocardial scintigraphy

    International Nuclear Information System (INIS)

    Chalela, William Azem; Soares, J. Jr.; Meneghetti, J.C.; Olivera, C.G.; Moffa, P.J.; Falcao, A.M.; Ramires, J.A.F.

    2004-01-01

    The detection of viable myocardium after myocardial infarction is an important indication for revascularization. We compared exercise-induced ST segment elevation with reversibility at Thallium-201 SPECT scintigraphy and regional wall motion assessment by ventriculography. Thirty two patients with previous myocardial infarction and with left ventricular ejection fraction of < 50% were studied. Patients underwent coronary angiography and Thallium-201 SPECT scintigraphy with re-injection protocol before and after coronary artery bypass graft surgery. Group I comprised 11 patients with ST segment elevation during treadmill stress testing. Group II comprised 21 patients without ST segment elevation. Minimal or moderate hypokinesis was present in 2 patients of Group I and in 4 patients of Group II. Nine patients of Group I and 17 patients of Group II had severe hypokinetic, akinetic or dyskinetic myocardium. Scintigraphy revealed reversibility in the myocardial infarction area in 4 patients from Group I (36.4%) and 11 (52.4%) patients from Group II. Improvement in perfusion after coronary artery bypass grafting was observed in 4 patients from Group I and 8 patients from Group II. Sensitivity, specificity, accuracy, and positive and negative predictive values of ST segment elevation were 33.3, 70.6, 55.2, 44.5 and 60% respectively. It was concluded that exercise-induced ST segment elevation after myocardial infarction is present more frequently in cases of severe regional myocardial dysfunction. (author)

  7. High-resolution near real-time drought monitoring in South Asia

    OpenAIRE

    Aadhar, Saran; Mishra, Vimal

    2017-01-01

    Drought in South Asia affect food and water security and pose challenges for millions of people. For policy-making, planning, and management of water resources at sub-basin or administrative levels, high-resolution datasets of precipitation and air temperature are required in near-real time. We develop a high-resolution (0.05°) bias-corrected precipitation and temperature data that can be used to monitor near real-time drought conditions over South Asia. Moreover, the dataset can be used to m...

  8. Perfusion Computed Tomography for the Assessment of Myocardial Viability — a Case Series

    Directory of Open Access Journals (Sweden)

    Morariu Mirabela

    2016-06-01

    Full Text Available Myocardial viability plays an important role in preventing the development of left ventricular remodeling following an acute myocardial infarction. A preserved viability in the infarcted area has been demonstrated to be associated with a lower amplitude of the remodeling process, while the extent of the non-viable myocardium is directly correlated with the amplitude of the remodeling process. A number of methods are currently in use for the quantification of the viable myocardium, and some of them are based on the estimation of myocardial perfusion during pharmacologic stress. 64-slice Multi-detector Computed Tomography (MDCT during vasodilator stress test, associated with CT Coronary Angiography (CCTA has a high diagnostic accuracy in evaluating myocardial perfusion. In this article, we present a sequence of 3 clinical cases that presented with symptoms of myocardial ischemia, who underwent 64-slice MDCT imaging at rest and during adenosine stress test, in order to assess the extent of the hypoperfused myocardial areas. Coronary artery anatomy and the Coronary Calcium Score was assessed for all 3 patients by performing CT Coronary Angiography. The combination of CT Angiography and adenosine stress CT myocardial perfusion imaging can accurately detect atherosclerosic lesions that cause perfusion abnormalities, compared with the combination of invasive angiography and single-photon emission computed tomography (SPECT.

  9. High resolution estimates of the corrosion risk for cultural heritage in Italy

    International Nuclear Information System (INIS)

    De Marco, Alessandra; Screpanti, Augusto; Mircea, Mihaela; Piersanti, Antonio; Proietti, Chiara; Fornasier, M. Francesca

    2017-01-01

    Air pollution plays a pivotal role in the deterioration of many materials used in buildings and cultural monuments causing an inestimable damage. This study aims to estimate the impacts of air pollution (SO 2 , HNO 3 , O 3 , PM 10 ) and meteorological conditions (temperature, precipitation, relative humidity) on limestone, copper and bronze based on high resolution air quality data-base produced with AMS-MINNI modelling system over the Italian territory over the time period 2003–2010. A comparison between high resolution data (AMS-MINNI grid, 4 × 4 km) and low resolution data (EMEP grid, 50 × 50 km) has been performed. Our results pointed out that the corrosion levels for limestone, copper and bronze are decreased in Italy from 2003 to 2010 in relation to decrease of pollutant concentrations. However, some problem related to air pollution persists especially in Northern and Southern Italy. In particular, PM 10 and HNO 3 are considered the main responsible for limestone corrosion. Moreover, the high resolution data (AMS-MINNI) allowed the identification of risk areas that are not visible with the low resolution data (EMEP modelling system) in all considered years and, especially, in the limestone case. Consequently, high resolution air quality simulations are suitable to provide concrete benefits in providing information for national effective policy against corrosion risk for cultural heritage, also in the context of climate changes that are affecting strongly Mediterranean basin. - Highlights: • Air pollution plays a pivotal role in the deterioration of cultural materials. • Limestone, copper and bronze corrosion levels decreased in Italy from 2003 to 2010. • PM 10 is considered the main responsible for limestone corrosion in Northern Italy. • HNO3 is considered the main responsible for limestone corrosion in all analyzed years. • High-resolution data are particularly useful to define area at risk for corrosion. - Importance of the high-resolution

  10. The expression of myocardial injury in cold induced myocardial imaging and echocardiography of systematic scleroderma

    International Nuclear Information System (INIS)

    Liang Jiugen; Zhu Xiaojun; Jiang Ningyi; Chen Shaoxiong

    1999-01-01

    The study was performed with cold-induced 99m Tc(MIBI) myocardial imaging (MI) in 23 patients with systematic scleroderma. The left ventricular function and wall motion were also observed by dimensional echocardiography (UCG). 14 patients had myocardial perfusion abnormalities visualized by MI, including 5 cases with fixed defects of 9 segments, 3 cases with reversible defects of 6 segments and 6 cases with both fixed and reversible one of 14 segments. The positive rate in myocardial imaging had no significant differences between patients with and without Raynaud's phenomenon (0.5>P>0.25). Compared with baseline, the ejection fraction, stroke volume, cardiac output were significantly decreased during cold-induced in patients with abnormal myocardial scintigraphy (P<0.05), and had significant difference compared with normal group (P<0.05). 4 cases with cold-induced reversible perfusion defects had anatomically correlated regional ventricular hypokinesia in UCG

  11. Echocardiography as a Screening Test for Myocardial Scarring in Children with Hypertrophic Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Gregory Compton

    2016-01-01

    Full Text Available Introduction. Hypertrophic cardiomyopathy (HCM is burdened with morbidity and mortality including tachyarrhythmias and sudden cardiac death. These complications are attributed in part to the formation of proarrhythmic scars in the myocardium. The presence of extensive LGE is a risk factor for adverse outcomes in HCM. Late gadolinium enhancement (LGE cardiac magnetic resonance imaging (cMRI is the standard for the noninvasive evaluation of myocardial scars. However, echocardiography represents an attractive screening tool for myocardial scarring. The aim of this study was to compare the suitability of echocardiography to detect myocardial scars to the standard of cMRI-LGE. Methods. The cMRI studies and echocardiograms from 56 consecutive children with HCM were independently evaluated for the presence of cMRI-LGE and echocardiographic evidence of scarring by expert readers. Results. Echocardiography had a high sensitivity (93% and negative predictive value (94% in comparison to LGE. The false positive rate was high, leading to a low specificity (37% and a low positive predictive value (35%. Conclusions. Given the poor specificity and positive predictive value, echocardiography is not a suitable screening test for the presence of myocardial scarring in children with HCM. However, children without echocardiographic evidence of myocardial scarring may not need to undergo cardiac magnetic resonance imaging to “rule in” LGE.

  12. Prognostic impact of physical activity prior to myocardial infarction

    DEFF Research Database (Denmark)

    Ejlersen, Hanne; Andersen, Zorana Jovanovic; von Euler-Chelpin, My Catarina

    2017-01-01

    the course of myocardial infarction by reducing case fatality and the subsequent risk of heart failure and mortality. Methods: A total of 14,223 participants in the Copenhagen City Heart Study were assessed at baseline in 1976-1978; 1,664 later developed myocardial infarction (mean age at myocardial...... estimated by logistic and Cox proportional hazards regression models, adjusted for age at myocardial infarction and other potential confounders. Results: A total of 425 (25.5%) myocardial infarctions were fatal. Higher levels of LTPA prior to myocardial infarction were associated with lower case fatality...

  13. High-resolution computer-aided moire

    Science.gov (United States)

    Sciammarella, Cesar A.; Bhat, Gopalakrishna K.

    1991-12-01

    This paper presents a high resolution computer assisted moire technique for the measurement of displacements and strains at the microscopic level. The detection of micro-displacements using a moire grid and the problem associated with the recovery of displacement field from the sampled values of the grid intensity are discussed. A two dimensional Fourier transform method for the extraction of displacements from the image of the moire grid is outlined. An example of application of the technique to the measurement of strains and stresses in the vicinity of the crack tip in a compact tension specimen is given.

  14. High flux and high resolution VUV beam line for synchrotron radiation

    International Nuclear Information System (INIS)

    Wilcke, H.; Boehmer, W.; Schwentner, N.

    1982-04-01

    A beam line has been optimized for high flux and high resolution in the wavelength range from 30 nm to 300 nm. Sample chambers for luminescence spectroscopy on gaseous, liquid and solid samples and for photoelectron spectroscopy have been integrated. The synchrotron radiation from the storage ring DORIS (at DESY, Hamburg) emitted into 50 mrad in horizontal and into 2.2 mrad in vertical direction is focused by a cylindrical and a plane elliptical mirror into the entrance slit of a 2m normal incidence monochromator. The light flux from the exit slit is focused by a rotational elliptic mirror onto the sample yielding a size of the light spot of 4 x 0.15 mm 2 . The light flux at the sample reaches 7 x 10 12 photons nm -1 s -1 at 8 eV photon energy for a current of 100 mA in DORIS. A resolution of 0.007 nm has been obtained. (orig.)

  15. Pyrosequencing™ : A one-step method for high resolution HLA typing

    Directory of Open Access Journals (Sweden)

    Marincola Francesco M

    2003-11-01

    Full Text Available Abstract While the use of high-resolution molecular typing in routine matching of human leukocyte antigens (HLA is expected to improve unrelated donor selection and transplant outcome, the genetic complexity of HLA still makes the current methodology limited and laborious. Pyrosequencing™ is a gel-free, sequencing-by-synthesis method. In a Pyrosequencing reaction, nucleotide incorporation proceeds sequentially along each DNA template at a given nucleotide dispensation order (NDO that is programmed into a pyrosequencer. Here we describe the design of a NDO that generates a pyrogram unique for any given allele or combination of alleles. We present examples of unique pyrograms generated from each of two heterozygous HLA templates, which would otherwise remain cis/trans ambiguous using standard sequencing based typing (SBT method. In addition, we display representative data that demonstrate long read and linear signal generation. These features are prerequisite of high-resolution typing and automated data analysis. In conclusion Pyrosequencing is a one-step method for high resolution DNA typing.

  16. Development of high resolution Michelson interferometer for stable phase-locked ultrashort pulse pair generation.

    Science.gov (United States)

    Okada, Takumi; Komori, Kazuhiro; Goshima, Keishiro; Yamauchi, Shohgo; Morohashi, Isao; Sugaya, Takeyoshi; Ogura, Mutsuo; Tsurumachi, Noriaki

    2008-10-01

    We developed a high resolution Michelson interferometer with a two-frequency He-Ne laser positioning system in order to stabilize the relative phase of a pulse pair. The control resolution corresponded to a 12 as time resolution or a phase of 1.5 degrees at 900 nm. This high resolution Michelson interferometer can generate a phase-locked pulse pair either with a specific relative phase such as 0 or pi radians or with an arbitrary phase. Coherent control of an InAs self-assembled quantum dot was demonstrated using the high resolution Michelson interferometer with a microspectroscopy system.

  17. Study on the performance of large area MRPC with high position resolution

    Energy Technology Data Exchange (ETDEWEB)

    Yue Qian, E-mail: yueq@mail.tsinghua.edu.cn [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education (China); Wu Yucheng; Li Yuanjing; Ye Jin; Cheng Jianping; Wang Yi; Li Jin [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education (China)

    2012-01-01

    Multi-gap resistive plate chamber (MRPC), which is mostly developed in high energy physics domain with excellent time resolution, is also highlighted in imaging applications. A set of 50 cm Multiplication-Sign 50 cm large area MRPC with high position resolution was successfully developed by our group and different experiments have been done to test its performances. Cosmic ray muons were used to do the test and proper high voltage and working gas were chosen. Data analysis indicates its good detection efficiency and good position resolution, which encourages further study of its application in RPC-PET and muon tomography.

  18. High-resolution satellite imagery is an important yet underutilized resource in conservation biology.

    Science.gov (United States)

    Boyle, Sarah A; Kennedy, Christina M; Torres, Julio; Colman, Karen; Pérez-Estigarribia, Pastor E; de la Sancha, Noé U

    2014-01-01

    Technological advances and increasing availability of high-resolution satellite imagery offer the potential for more accurate land cover classifications and pattern analyses, which could greatly improve the detection and quantification of land cover change for conservation. Such remotely-sensed products, however, are often expensive and difficult to acquire, which prohibits or reduces their use. We tested whether imagery of high spatial resolution (≤5 m) differs from lower-resolution imagery (≥30 m) in performance and extent of use for conservation applications. To assess performance, we classified land cover in a heterogeneous region of Interior Atlantic Forest in Paraguay, which has undergone recent and dramatic human-induced habitat loss and fragmentation. We used 4 m multispectral IKONOS and 30 m multispectral Landsat imagery and determined the extent to which resolution influenced the delineation of land cover classes and patch-level metrics. Higher-resolution imagery more accurately delineated cover classes, identified smaller patches, retained patch shape, and detected narrower, linear patches. To assess extent of use, we surveyed three conservation journals (Biological Conservation, Biotropica, Conservation Biology) and found limited application of high-resolution imagery in research, with only 26.8% of land cover studies analyzing satellite imagery, and of these studies only 10.4% used imagery ≤5 m resolution. Our results suggest that high-resolution imagery is warranted yet under-utilized in conservation research, but is needed to adequately monitor and evaluate forest loss and conversion, and to delineate potentially important stepping-stone fragments that may serve as corridors in a human-modified landscape. Greater access to low-cost, multiband, high-resolution satellite imagery would therefore greatly facilitate conservation management and decision-making.

  19. Utilization of Short-Simulations for Tuning High-Resolution Climate Model

    Science.gov (United States)

    Lin, W.; Xie, S.; Ma, P. L.; Rasch, P. J.; Qian, Y.; Wan, H.; Ma, H. Y.; Klein, S. A.

    2016-12-01

    Many physical parameterizations in atmospheric models are sensitive to resolution. Tuning the models that involve a multitude of parameters at high resolution is computationally expensive, particularly when relying primarily on multi-year simulations. This work describes a complementary set of strategies for tuning high-resolution atmospheric models, using ensembles of short simulations to reduce the computational cost and elapsed time. Specifically, we utilize the hindcast approach developed through the DOE Cloud Associated Parameterization Testbed (CAPT) project for high-resolution model tuning, which is guided by a combination of short (tests have been found to be effective in numerous previous studies in identifying model biases due to parameterized fast physics, and we demonstrate that it is also useful for tuning. After the most egregious errors are addressed through an initial "rough" tuning phase, longer simulations are performed to "hone in" on model features that evolve over longer timescales. We explore these strategies to tune the DOE ACME (Accelerated Climate Modeling for Energy) model. For the ACME model at 0.25° resolution, it is confirmed that, given the same parameters, major biases in global mean statistics and many spatial features are consistent between Atmospheric Model Intercomparison Project (AMIP)-type simulations and CAPT-type hindcasts, with just a small number of short-term simulations for the latter over the corresponding season. The use of CAPT hindcasts to find parameter choice for the reduction of large model biases dramatically improves the turnaround time for the tuning at high resolution. Improvement seen in CAPT hindcasts generally translates to improved AMIP-type simulations. An iterative CAPT-AMIP tuning approach is therefore adopted during each major tuning cycle, with the former to survey the likely responses and narrow the parameter space, and the latter to verify the results in climate context along with assessment in

  20. Validation of High-resolution Climate Simulations over Northern Europe.

    Science.gov (United States)

    Muna, R. A.

    2005-12-01

    Two AMIP2-type (Gates 1992) experiments have been performed with climate versions of ARPEGE/IFS model examine for North Atlantic North Europe, and Norwegian region and analyzed the effect of increasing resolution on the simulated biases. The ECMWF reanalysis or ERA-15 has been used to validate the simulations. Each of the simulations is an integration of the period 1979 to 1996. The global simulations used observed monthly mean sea surface temperatures (SST) as lower boundary condition. All aspects but the horizontal resolutions are similar in the two simulations. The first simulation has a uniform horizontal resolution of T63L. The second one has a variable resolution (T106Lc3) with the highest resolution in the Norwegian Sea. Both simulations have 31 vertical layers in the same locations. For each simulation the results were divided into two seasons: winter (DJF) and summer (JJA). The parameters investigated were mean sea level pressure, geopotential and temperature at 850 hPa and 500 hPa. To find out the causes of temperature bias during summer, latent and sensible heat flux, total cloud cover and total precipitation were analyzed. The high-resolution simulation exhibits more or less realistic climate over Nordic, Artic and European region. The overall performance of the simulations shows improvements of generally all fields investigated with increasing resolution over the target area both in winter (DJF) and summer (JJA).