Short- and long-term reliability of language fMRI.
Nettekoven, Charlotte; Reck, Nicola; Goldbrunner, Roland; Grefkes, Christian; Weiß Lucas, Carolin
2018-08-01
When using functional magnetic resonance imaging (fMRI) for mapping important language functions, a high test-retest reliability is mandatory, both in basic scientific research and for clinical applications. We, therefore, systematically tested the short- and long-term reliability of fMRI in a group of healthy subjects using a picture naming task and a sparse-sampling fMRI protocol. We hypothesized that test-retest reliability might be higher for (i) speech-related motor areas than for other language areas and for (ii) the short as compared to the long intersession interval. 16 right-handed subjects (mean age: 29 years) participated in three sessions separated by 2-6 (session 1 and 2, short-term) and 21-34 days (session 1 and 3, long-term). Subjects were asked to perform the same overt picture naming task in each fMRI session (50 black-white images per session). Reliability was tested using the following measures: (i) Euclidean distances (ED) between local activation maxima and Centers of Gravity (CoGs), (ii) overlap volumes and (iii) voxel-wise intraclass correlation coefficients (ICCs). Analyses were performed for three regions of interest which were chosen based on whole-brain group data: primary motor cortex (M1), superior temporal gyrus (STG) and inferior frontal gyrus (IFG). Our results revealed that the activation centers were highly reliable, independent of the time interval, ROI or hemisphere with significantly smaller ED for the local activation maxima (6.45 ± 1.36 mm) as compared to the CoGs (8.03 ± 2.01 mm). In contrast, the extent of activation revealed rather low reliability values with overlaps ranging from 24% (IFG) to 56% (STG). Here, the left hemisphere showed significantly higher overlap volumes than the right hemisphere. Although mean ICCs ranged between poor (ICC0.75) were found for all ROIs. Voxel-wise reliability of the different ROIs was influenced by the intersession interval. Taken together, we could show that, despite of
Assessing high reliability via Bayesian approach and accelerated tests
International Nuclear Information System (INIS)
Erto, Pasquale; Giorgio, Massimiliano
2002-01-01
Sometimes the assessment of very high reliability levels is difficult for the following main reasons: - the high reliability level of each item makes it impossible to obtain, in a reasonably short time, a sufficient number of failures; - the high cost of the high reliability items to submit to life tests makes it unfeasible to collect enough data for 'classical' statistical analyses. In the above context, this paper presents a Bayesian solution to the problem of estimation of the parameters of the Weibull-inverse power law model, on the basis of a limited number (say six) of life tests, carried out at different stress levels, all higher than the normal one. The over-stressed (i.e. accelerated) tests allow the use of experimental data obtained in a reasonably short time. The Bayesian approach enables one to reduce the required number of failures adding to the failure information the available a priori engineers' knowledge. This engineers' involvement conforms to the most advanced management policy that aims at involving everyone's commitment in order to obtain total quality. A Monte Carlo study of the non-asymptotic properties of the proposed estimators and a comparison with the properties of maximum likelihood estimators closes the work
Test-Retest Reliability of the Short-Form Survivor Unmet Needs Survey.
Taylor, Karen; Bulsara, Max; Monterosso, Leanne
2018-01-01
Reliable and valid needs assessment measures are important assessment tools in cancer survivorship care. A new 30-item short-form version of the Survivor Unmet Needs Survey (SF-SUNS) was developed and validated with cancer survivors, including hematology cancer survivors; however, test-retest reliability has not been established. The objective of this study was to assess the test-retest reliability of the SF-SUNS with a cohort of lymphoma survivors ( n = 40). Test-retest reliability of the SF-SUNS was conducted at two time points: baseline (time 1) and 5 days later (time 2). Test-retest data were collected from lymphoma cancer survivors ( n = 40) in a large tertiary cancer center in Western Australia. Intraclass correlation analyses compared data at time 1 (baseline) and time 2 (5 days later). Cronbach's alpha analyses were performed to assess the internal consistency at both time points. The majority (23/30, 77%) of items achieved test-retest reliability scores 0.45-0.74 (fair to good). A high degree of overall internal consistency was demonstrated (time 1 = 0.92, time 2 = 0.95), with scores 0.65-0.94 across subscales for both time points. Mixed test-retest reliability of the SF-SUNS was established. Our results indicate the SF-SUNS is responsive to the changing needs of lymphoma cancer survivors. Routine use of cancer survivorship specific needs-based assessments is required in oncology care today. Nurses are well placed to administer these assessments and provide tailored information and resources. Further assessment of test-retest reliability in hematology and other cancer cohorts is warranted.
Reliability of high power electron accelerators for radiation processing
Energy Technology Data Exchange (ETDEWEB)
Zimek, Z. [Department of Radiation Chemistry and Technology, Institute of Nuclear Chemistry and Technology, Warsaw (Poland)
2011-07-01
Accelerators applied for radiation processing are installed in industrial facilities where accelerator availability coefficient should be at the level of 95% to fulfill requirements according to industry standards. Usually the exploitation of electron accelerator reviles the number of short and few long lasting failures. Some technical shortages can be overcome by practical implementation the experience gained in accelerator technology development by different accelerator manufactures. The reliability/availability of high power accelerators for application in flue gas treatment process must be dramatically improved to meet industrial standards. Support of accelerator technology dedicated for environment protection should be provided by governmental and international institutions to overcome accelerator reliability/availability problem and high risk and low direct profit in this particular application. (author)
Reliability of high power electron accelerators for radiation processing
International Nuclear Information System (INIS)
Zimek, Z.
2011-01-01
Accelerators applied for radiation processing are installed in industrial facilities where accelerator availability coefficient should be at the level of 95% to fulfill requirements according to industry standards. Usually the exploitation of electron accelerator reviles the number of short and few long lasting failures. Some technical shortages can be overcome by practical implementation the experience gained in accelerator technology development by different accelerator manufactures. The reliability/availability of high power accelerators for application in flue gas treatment process must be dramatically improved to meet industrial standards. Support of accelerator technology dedicated for environment protection should be provided by governmental and international institutions to overcome accelerator reliability/availability problem and high risk and low direct profit in this particular application. (author)
DEFF Research Database (Denmark)
Ding, Yi; Singh, Chanan; Goel, Lalit
2014-01-01
reliability evaluation techniques for power systems are well developed. These techniques are more focused on steady-state (time-independent) reliability evaluation and have been successfully applied in power system planning and expansion. In the operational phase, however, they may be too rough......The expanding share of the fluctuating and less predictable wind power generation can introduce complexities in power system reliability evaluation and management. This entails a need for the system operator to assess the system status more accurately for securing real-time balancing. The existing...... an approximation of the time-varying behavior of power systems with high penetration of wind power. This paper proposes a time-varying reliability assessment technique. Time-varying reliability models for wind farms, conventional generating units, and rapid start-up generating units are developed and represented...
Morales, Alexandra; Reis, Sibília; Espada, José P; Orgilés, Mireia
2016-09-01
The Short Health Anxiety Inventory is a brief instrument to assess health anxiety widely used across countries; however, no validated version is available for Portuguese-speaking population. Factorial structure, reliability, and equivalency factor with the Spanish version were analyzed with Portuguese adolescents aged 14-18 years. A Portuguese adolescent cohort ( N = 629) and a comparative Spanish adolescent cohort ( N = 1502) were evaluated. The original two-factor version was the best fitting model for the Portuguese version. The reliability was excellent. Complete measurement invariance across both countries was supported. The Portuguese version of the Short Health Anxiety Inventory is a valid screening inventory to assess health anxiety in adolescents.
Reliability and Validity of a Short Scale of Attitude toward Christianity ...
African Journals Online (AJOL)
To facilitate cross-cultural research in the psychology of religion, the reliability and validity of the 7-item short form of the Francis Scale of Attitude toward Christianity was examined among a sample of 453 young people aged between 12-19 years old from standards six, seven, eight, nine and ten attending a secondary ...
Transient analysis of the output short-circuit fault of high power and high voltage DC power supply
International Nuclear Information System (INIS)
Yang Zhigang; Zhang Jian; Huang Yiyun; Hao Xu; Sun Haozhang; Guo Fei
2014-01-01
The transient conditions of output short-circuit fault of high voltage DC power supply was introduced, and the energy of power supply injecting into klystron during the protection process of three-electrode gas switch were analyzed and calculated in detail when klystron load happening electrode arc faults. The results of calculation and simulation are consistent with the results of the experiment. When the output short-circuit fault of high voltage power supply occurs, switch can be shut off in the microsecond, and the short circuit current can be controlled in 200 A. It has verified the rapidity and reliability of the three-electrode gas switch protection, and it has engineering application value. (authors)
Reliability of BOD POD Measurements Remains High After a Short-Duration Low-Carbohydrate Diet.
Greer, Beau Kjerulf; Edsall, Kathleen M; Greer, Anna E
2016-04-01
The purpose of the current study was to determine whether expected changes in body weight via a 3-day low-carbohydrate (LC) diet will disrupt the reliability of air displacement plethysmography measurements via BOD POD. Twenty-four subjects recorded their typical diets for 3 days before BOD POD and 7-site skinfold analyses. Subjects were matched for lean body mass and divided into low-CHO (LC) and control (CON) groups. The LC group was given instruction intended to prevent more than 50 grams/day of carbohydrate consumption for 3 consecutive days, and the CON group replicated their previously recorded diet. Body composition measurements were repeated after dietary intervention. Test-retest reliability measures were significant (p fat percentage in both the LC and the CON groups (rs = .993 and .965, respectively). Likewise, skinfold analysis for body fat percentage reliability was high in both groups (rs = .996 and .997, respectively). There were significant differences between 1st and 2nd BOD POD measurements for body mass (72.9 ± 13.3 vs. 72.1 ± 13.0 kg [M ± SD]) and body volume (69.0 ± 12.7-68.1 ± 12.2 L) in the LC group (p .05) in BOD POD-determined body fat percentage, lean body mass, or fat mass between the 1st and 2nd trial in either group. Body composition measures via BOD POD and 7-site skinfolds remain reliable after 3 days of an LC diet despite significant decreases in body mass.
Analysis of High Power IGBT Short Circuit Failures
Energy Technology Data Exchange (ETDEWEB)
Pappas, G.
2005-02-11
The Next Linear Collider (NLC) accelerator proposal at SLAC requires a highly efficient and reliable, low cost, pulsed-power modulator to drive the klystrons. A solid-state induction modulator has been developed at SLAC to power the klystrons; this modulator uses commercial high voltage and high current Insulated Gate Bipolar Transistor (IGBT) modules. Testing of these IGBT modules under pulsed conditions was very successful; however, the IGBTs failed when tests were performed into a low inductance short circuit. The internal electrical connections of a commercial IGBT module have been analyzed to extract self and mutual partial inductances for the main current paths as well as for the gate structure. The IGBT module, together with the partial inductances, has been modeled using PSpice. Predictions for electrical paths that carry the highest current correlate with the sites of failed die under short circuit tests. A similar analysis has been carried out for a SLAC proposal for an IGBT module layout. This paper discusses the mathematical model of the IGBT module geometry and presents simulation results.
Influence of platform diameter in the reliability and failure mode of extra-short dental implants.
Bordin, Dimorvan; Bergamo, Edmara T P; Bonfante, Estevam A; Fardin, Vinicius P; Coelho, Paulo G
2018-01-01
To evaluate the influence of implant diameter in the reliability and failure mode of extra-short dental implants. Sixty-three extra-short implants (5mm-length) were allocated into three groups according to platform diameter: Ø4.0-mm, Ø5.0-mm, and Ø6.0-mm (21 per group). Identical abutments were torqued to the implants and standardized crowns cemented. Three samples of each group were subjected to single-load to failure (SLF) to allow the design of the step-stress profiles, and the remaining 18 were subjected to step-stress accelerated life-testing (SSALT) in water. The use level probability Weibull curves, and the reliability (probability of survival) for a mission of 100,000 cycles at 100MPa, 200MPa, and 300MPa were calculated. Failed samples were characterized in scanning electron microscopy for fractographic inspection. No significant difference was observed for reliability regarding implant diameter for all loading missions. At 100MPa load, all groups showed reliability higher than 99%. A significant decreased reliability was observed for all groups when 200 and 300MPa missions were simulated, regardless of implant diameter. At 300MPa load, the reliability was 0%, 0%, and 5.24%, for Ø4.0mm, Ø5.0mm, and Ø6.0mm, respectively. The mean beta (β) values were lower than 0.55 indicating that failures were most likely influenced by materials strength, rather than damage accumulation. The Ø6.0mm implant showed significantly higher characteristic stress (η = 1,100.91MPa) than Ø4.0mm (1,030.25MPa) and Ø5.0mm implant (η = 1,012.97MPa). Weibull modulus for Ø6.0-mm implant was m = 7.41, m = 14.65 for Ø4.0mm, and m = 11.64 for Ø5.0mm. The chief failure mode was abutment fracture in all groups. The implant diameter did not influence the reliability and failure mode of 5mm extra-short implants. Copyright © 2017 Elsevier Ltd. All rights reserved.
DEFF Research Database (Denmark)
Sørensen, Lotte; Mikkelsen, Lone Ramer; Jacobsen, Julie Sandell
2018-01-01
Objective: To translate and cross-cultural adapt the short questionnaire to assess health-enhancing physical activity (SQUASH) to Danish, and to investigate the Danish version’s reliability. Methods: The study was conducted according to the COSMIN guidelines. The reliability was evaluated in 53...... and indicates that the Danish version of SQUASH can be used to distinguish between individuals; however, the absolute reliability was poor and SQUASH is not considered suitable for easuring physical activity on an individual level....
Reliability of short form-36 in an Internet- and a pen-and-paper version
DEFF Research Database (Denmark)
Basnov, Maja; Kongsved, Sissel Marie; Bech, Per
2009-01-01
Use of Internet versions of questionnaires may have several advantages in clinical and epidemiological research, but we know little about if Internet versions differ with respect to validity and reliability. We aimed to compare Internet- and pen-and-paper versions of short form-36 (SF-36......) with respect to test-retest reliability and internal consistency. Women referred to mammography (n = 782) were randomised to receive either a paper version with a prepaid return envelope or a guideline on how to fill in the Internet version. A subgroup was asked to answer the questionnaire once again...... in the alternative version. Test-retest reliability was assessed by the intra-class correlation coefficient. Internal consistency was calculated as Cronbach's alpha. The between-version test-retest reliability for the eight subscales were between 0.63 and 0.92. Cronbach's alpha for the two versions were all between...
MCGUCKIN, CONOR
2006-01-01
PUBLISHED The Oxford Happiness Questionnaire short-form is a recently developed eight-item measure of happiness. This study evaluated the internal consistency reliability and test-retest reliability of the Oxford Happiness Questionnaire short-form among 55 Northern Irish undergraduate university students who completed the measure on two occasions separated by two weeks. Internal consistency of the measure on both occasions was satisfactory at both Time 1 (alpha = .62) and Time 2 (alpha = ....
Wang, Chao; Chen, Peijie; Zhuang, Jie
2013-01-01
Purpose: The psychometric profiles of the widely used International Physical Activity Questionnaire-Short Form (IPAQ-SF) in Chinese youth have not been reported. The purpose of this study was to examine the validity and reliability of the IPAQ-SF using a sample of Chinese youth. Method: One thousand and twenty-one youth (M[subscript age] = 14.26 ±…
Olsen, Cecilie Fromholt; Bergland, Astrid
2017-06-09
The purpose of the study was to establish the test-retest reliability of the Norwegian version of the Short Physical Performance Battery (SPPB). This was a cross- sectional reliability study. A convenience sample of 61 older adults with a mean age of 88.4(8.1) was tested by two different physiotherapists at two time points. The mean time interval between tests was 2.5 days. The Intraclass Correlation Coefficient model 3.1 (ICC, 3.1) with 95% confidence intervals as well as the weighted Kappa (K) were used as measures of relative reliability. The Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC) were used to measure absolute reliability. The results were also analyzed for a subgroup of 24 older people with dementia. The ICC reflected high relative reliability for the SPPB summary score and the 4 m walk test (4mwt), both for the total sample (ICC = 0.92, and 0.91 respectively)) and for the subgroup with dementia (ICC = 0.84 and 0.90 respectively). Furthermore, weighted Ks for the SPPB subscales were 0.64 for the chair stand, 0.80 for gait and 0.52 for balance for the total sample and almost identical for the subgroup with dementia. MDC-values at the 95% confidence intervals (MDC95) were calculated at 0.8 for the total score of SPPB and 0.39 m/s for the 4mwt in the total sample. For the subgroup with dementia MDC95 was 1.88 for the total score of SPPB and 0.28 m/s for 4mwt. The SPPB total score and the timed walking test showed overall high relative and absolute reliability for the total sample indicating that the Norwegian version of the SPPB is reliable when used by trained physiotherapists with older people. The reliability of the Norwegian SPPB in older people with dementia seems high, but due to a small sample size this needs further investigation.
Advanced Functionalities for Highly Reliable Optical Networks
DEFF Research Database (Denmark)
An, Yi
This thesis covers two research topics concerning optical solutions for networks e.g. avionic systems. One is to identify the applications for silicon photonic devices for cost-effective solutions in short-range optical networks. The other one is to realise advanced functionalities in order...... to increase the availability of highly reliable optical networks. A cost-effective transmitter based on a directly modulated laser (DML) using a silicon micro-ring resonator (MRR) to enhance its modulation speed is proposed, analysed and experimentally demonstrated. A modulation speed enhancement from 10 Gbit...... interconnects and network-on-chips. A novel concept of all-optical protection switching scheme is proposed, where fault detection and protection trigger are all implemented in the optical domain. This scheme can provide ultra-fast establishment of the protection path resulting in a minimum loss of data...
Reliability and Validity Study of the Attitude towards Mathematics Instruments Short Form
Directory of Open Access Journals (Sweden)
Güney HACIÖMEROĞLU
2017-05-01
Full Text Available Purpose of this study was to investigate the reliability and validity of the Turkish form of the Attitude Towards Mathematics Instrument Short Form developed by Lim and Chapman (2013. In this study, data gathered from 310 elementary students were utilized for Exploratory and Confirmatory Factor Analysis to determine the structure of factor loading. The factor loading among the sub-scales were different from original. Confirmatory Factor analysis revealed that the model was acceptable. There were three sub-scales, value, self-confidence, enjoyment and motivation. Cronbach’s alpha coefficient for the overall instrument was calculated as .84, respectively. The adapted instrument includes three sub-scales: value (α=.91, self-confidence (α=.86, enjoyment and motivation (α=.82. Turkish adaptation of the questionnaire is valid and reliable and appropriate to use in Turkish culture.
Reliability and validity of the Japanese version of the Resilience Scale and its short version
Directory of Open Access Journals (Sweden)
Kondo Maki
2010-11-01
Full Text Available Abstract Background The clinical relevance of resilience has received considerable attention in recent years. The aim of this study is to demonstrate the reliability and validity of the Japanese version of the Resilience Scale (RS and short version of the RS (RS-14. Findings The original English version of RS was translated to Japanese and the Japanese version was confirmed by back-translation. Participants were 430 nursing and university psychology students. The RS, Center for Epidemiologic Studies Depression Scale (CES-D, Rosenberg Self-Esteem Scale (RSES, Social Support Questionnaire (SSQ, Perceived Stress Scale (PSS, and Sheehan Disability Scale (SDS were administered. Internal consistency, convergent validity and factor loadings were assessed at initial assessment. Test-retest reliability was assessed using data collected from 107 students at 3 months after baseline. Mean score on the RS was 111.19. Cronbach's alpha coefficients for the RS and RS-14 were 0.90 and 0.88, respectively. The test-retest correlation coefficients for the RS and RS-14 were 0.83 and 0.84, respectively. Both the RS and RS-14 were negatively correlated with the CES-D and SDS, and positively correlated with the RSES, SSQ and PSS (all p Conclusions This study demonstrates that the Japanese version of RS has psychometric properties with high degrees of internal consistency, high test-retest reliability, and relatively low concurrent validity. RS-14 was equivalent to the RS in internal consistency, test-retest reliability, and concurrent validity. Low scores on the RS, a positive correlation between the RS and perceived stress, and a relatively low correlation between the RS and depressive symptoms in this study suggest that validity of the Japanese version of the RS might be relatively low compared with the original English version.
Exact reliability quantification of highly reliable systems with maintenance
Energy Technology Data Exchange (ETDEWEB)
Bris, Radim, E-mail: radim.bris@vsb.c [VSB-Technical University Ostrava, Faculty of Electrical Engineering and Computer Science, Department of Applied Mathematics, 17. listopadu 15, 70833 Ostrava-Poruba (Czech Republic)
2010-12-15
When a system is composed of highly reliable elements, exact reliability quantification may be problematic, because computer accuracy is limited. Inaccuracy can be due to different aspects. For example, an error may be made when subtracting two numbers that are very close to each other, or at the process of summation of many very different numbers, etc. The basic objective of this paper is to find a procedure, which eliminates errors made by PC when calculations close to an error limit are executed. Highly reliable system is represented by the use of directed acyclic graph which is composed from terminal nodes, i.e. highly reliable input elements, internal nodes representing subsystems and edges that bind all of these nodes. Three admissible unavailability models of terminal nodes are introduced, including both corrective and preventive maintenance. The algorithm for exact unavailability calculation of terminal nodes is based on merits of a high-performance language for technical computing MATLAB. System unavailability quantification procedure applied to a graph structure, which considers both independent and dependent (i.e. repeatedly occurring) terminal nodes is based on combinatorial principle. This principle requires summation of a lot of very different non-negative numbers, which may be a source of an inaccuracy. That is why another algorithm for exact summation of such numbers is designed in the paper. The summation procedure uses benefits from a special number system with the base represented by the value 2{sup 32}. Computational efficiency of the new computing methodology is compared with advanced simulation software. Various calculations on systems from references are performed to emphasize merits of the methodology.
Reliability testing of the Danish version of the Kidney Disease Quality of Life Short Form
DEFF Research Database (Denmark)
Molsted, Stig; Heaf, James; Prescott, Lotte
2005-01-01
. MATERIAL AND METHODS: Translation into Danish and back-translation into English were performed. Pilot, field and internal consistency reliability tests were performed. RESULTS: Cronbach's alpha coefficients for the internal reliability test ranged from 0.77 to 0.93 for the eight generic scales. In a test......OBJECTIVE: The questionnaire Kidney Disease Quality of Life Short Form version 1.3 (KDQOL-SF) is valuable for assessing the health-related quality of life in patients treated with chronic dialysis. The aim of this study was to translate and test the reliability of the KDQOL-SF for use in Denmark...... involving all patients, two of the disease-specific scales had Cronbach's alpha coefficients of test of the scores...
High-Reliability Health Care: Getting There from Here
Chassin, Mark R; Loeb, Jerod M
2013-01-01
Context Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer “project fatigue” because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. Methods We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals’ readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. Findings We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Conclusions Hospitals can make substantial progress toward high reliability by undertaking several specific
A least squares approach for efficient and reliable short-term versus long-term optimization
DEFF Research Database (Denmark)
Christiansen, Lasse Hjuler; Capolei, Andrea; Jørgensen, John Bagterp
2017-01-01
The uncertainties related to long-term forecasts of oil prices impose significant financial risk on ventures of oil production. To minimize risk, oil companies are inclined to maximize profit over short-term horizons ranging from months to a few years. In contrast, conventional production...... optimization maximizes long-term profits over horizons that span more than a decade. To address this challenge, the oil literature has introduced short-term versus long-term optimization. Ideally, this problem is solved by a posteriori multi-objective optimization methods that generate an approximation...... the balance between the objectives, leaving an unfulfilled potential to increase profits. To promote efficient and reliable short-term versus long-term optimization, this paper introduces a natural way to characterize desirable Pareto points and proposes a novel least squares (LS) method. Unlike hierarchical...
Development of a highly reliable CRT processor
International Nuclear Information System (INIS)
Shimizu, Tomoya; Saiki, Akira; Hirai, Kenji; Jota, Masayoshi; Fujii, Mikiya
1996-01-01
Although CRT processors have been employed by the main control board to reduce the operator's workload during monitoring, the control systems are still operated by hardware switches. For further advancement, direct controller operation through a display device is expected. A CRT processor providing direct controller operation must be as reliable as the hardware switches are. The authors are developing a new type of highly reliable CRT processor that enables direct controller operations. In this paper, we discuss the design principles behind a highly reliable CRT processor. The principles are defined by studies of software reliability and of the functional reliability of the monitoring and operation systems. The functional configuration of an advanced CRT processor is also addressed. (author)
Yildiz, Metin; Doma, Serian
2017-09-26
The effects of effortful swallowing and solid meal ingestions on heart rate variability (HRV) have been examined previously. The effects of spontaneous saliva swallowing on short-term HRV and reliability of HRV analysis have not been studied before. The effect of saliva swallowing on HRV analyses parameters [meanRRI, SDNN (standard deviation of normal-to-normal), LF (low frequency), HF (high frequency) powers, LH/HF] and the reliability of LF and HF powers were investigated by frequency, time-frequency and intraclass correlation coefficient (ICC) analyses. Electrocardiogram and swallowing signal that obtained from an electronic stethoscope placed on the necks of subjects were recorded simultaneously from 30 healthy and young volunteers in sitting position during 15 min. Spontaneous swallowing has been shown to significantly alter some HRV parameters (SDNN, LF power and LF/HF ratio). Time-frequency analysis results showed that the contribution of saliva swallowing to LF (1-58%) and HF (2-42%) powers could change significantly depending on the number of swallowing. The ICC of the LF and HF powers for the successive 5-min signal segments were found 0·89, 0·92, respectively. These values decreased to 0·73 and 0·90 in the subjects with more swallowing rate. When the analyses were made for 2-min signal periods, these values decreased to 0·63 and 0·67. We concluded that spontaneous saliva swallowing can change HRV parameters. We have also seen that changes in swallowing rate and use of short signal segments may reduce the reliability of HRV analyses. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
High-reliability health care: getting there from here.
Chassin, Mark R; Loeb, Jerod M
2013-09-01
Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer "project fatigue" because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals' readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Hospitals can make substantial progress toward high reliability by undertaking several specific organizational change initiatives. Further research
Contribution to high voltage matrix switches reliability
International Nuclear Information System (INIS)
Lausenaz, Yvan
2000-01-01
Nowadays, power electronic equipment requirements are important, concerning performances, quality and reliability. On the other hand, costs have to be reduced in order to satisfy the market rules. To provide cheap, reliability and performances, many standard components with mass production are developed. But the construction of specific products must be considered following these two different points: in one band you can produce specific components, with delay, over-cost problems and eventuality quality and reliability problems, in the other and you can use standard components in a adapted topologies. The CEA of Pierrelatte has adopted this last technique of power electronic conception for the development of these high voltage pulsed power converters. The technique consists in using standard components and to associate them in series and in parallel. The matrix constitutes high voltage macro-switch where electrical parameters are distributed between the synchronized components. This study deals with the reliability of these structures. It brings up the high reliability aspect of MOSFETs matrix associations. Thanks to several homemade test facilities, we obtained lots of data concerning the components we use. The understanding of defects propagation mechanisms in matrix structures has allowed us to put forwards the necessity of robust drive system, adapted clamping voltage protection, and careful geometrical construction. All these reliability considerations in matrix associations have notably allowed the construction of a new matrix structure regrouping all solutions insuring reliability. Reliable and robust, this product has already reaches the industrial stage. (author) [fr
Härdén, Marie; Nyström, Britta; Kulich, Károly; Carlsson, Jonas; Bengtson, Ann; Edvardsson, Nils
2009-07-15
Symptoms related to atrial fibrillation and their impact on health-related quality of life (HRQoL) are often evaluated in clinical trials. However, there remains a need for a properly validated instrument. We aimed to develop and validate a short symptoms scale for patients with AF. One hundred and eleven patients with a variety of symptoms related to AF were scheduled for DC cardioversion. The mean age was 67.1 +/- 12.1 years, and 80% were men. The patients completed the new symptoms scale, the Toronto Symptoms Check List (SCL) and the generic Short Form 36 (SF-36) the day before the planned DC cardioversion. Compliance was excellent, with only 1 of 666 answers missing. One item, 'limitations in working capability', was deleted because of a low numerical response rate, as many of the patients were retired. The internal consistency reliability of the remaining six items was 0.81 (Cronbach's alpha). Patients scored highest in the items of 'dyspnoea on exertion', 'limitations in daily life due to AF' and 'fatigue due to AF', with scores of 4.5, 3.3 and 4.5, respectively. There was a good correlation to all relevant SF-36 domains and to the relevant questions of the SCL. The Rasch analyses showed that the items are unidimensional and that they are clearly separated and cover an adequate range. Test-retest reliability was performed in patients who failed DC and was adequate for three of six items, > 0.70. The psychometric characteristics of the new short symptoms scale were found to have satisfactory reliability and validity.
Hayes, Corey J.; Bhandari, Naleen Raj; Kathe, Niranjan; Payakachat, Nalin
2017-01-01
Limited evidence exists on how non-cancer pain (NCP) affects an individual’s health-related quality of life (HRQoL). This study aimed to validate the Medical Outcomes Study Short Form-12 Version 2 (SF-12v2), a generic measure of HRQoL, in a NCP cohort using the Medical Expenditure Panel Survey Longitudinal Files. The SF Mental Component Summary (MCS12) and SF Physical Component Summary (PCS12) were tested for reliability (internal consistency and test-retest reliability) and validity (construct: convergent and discriminant; criterion: concurrent and predictive). A total of 15,716 patients with NCP were included in the final analysis. The MCS12 and PCS12 demonstrated high internal consistency (Cronbach’s alpha and Mosier’s alpha > 0.8), and moderate and high test-retest reliability, respectively (MCS12 intraclass correlation coefficient (ICC): 0.64; PCS12 ICC: 0.73). Both scales were significantly associated with a number of chronic conditions (p reliable and valid measure of HRQoL for patients with NCP. PMID:28445438
Temporal reliability and lateralization of the resting-state language network.
Zhu, Linlin; Fan, Yang; Zou, Qihong; Wang, Jue; Gao, Jia-Hong; Niu, Zhendong
2014-01-01
The neural processing loop of language is complex but highly associated with Broca's and Wernicke's areas. The left dominance of these two areas was the earliest observation of brain asymmetry. It was demonstrated that the language network and its functional asymmetry during resting state were reproducible across institutions. However, the temporal reliability of resting-state language network and its functional asymmetry are still short of knowledge. In this study, we established a seed-based resting-state functional connectivity analysis of language network with seed regions located at Broca's and Wernicke's areas, and investigated temporal reliability of language network and its functional asymmetry. The language network was found to be temporally reliable in both short- and long-term. In the aspect of functional asymmetry, the Broca's area was found to be left lateralized, while the Wernicke's area is mainly right lateralized. Functional asymmetry of these two areas revealed high short- and long-term reliability as well. In addition, the impact of global signal regression (GSR) on reliability of the resting-state language network was investigated, and our results demonstrated that GSR had negligible effect on the temporal reliability of the resting-state language network. Our study provided methodology basis for future cross-culture and clinical researches of resting-state language network and suggested priority of adopting seed-based functional connectivity for its high reliability.
Temporal reliability and lateralization of the resting-state language network.
Directory of Open Access Journals (Sweden)
Linlin Zhu
Full Text Available The neural processing loop of language is complex but highly associated with Broca's and Wernicke's areas. The left dominance of these two areas was the earliest observation of brain asymmetry. It was demonstrated that the language network and its functional asymmetry during resting state were reproducible across institutions. However, the temporal reliability of resting-state language network and its functional asymmetry are still short of knowledge. In this study, we established a seed-based resting-state functional connectivity analysis of language network with seed regions located at Broca's and Wernicke's areas, and investigated temporal reliability of language network and its functional asymmetry. The language network was found to be temporally reliable in both short- and long-term. In the aspect of functional asymmetry, the Broca's area was found to be left lateralized, while the Wernicke's area is mainly right lateralized. Functional asymmetry of these two areas revealed high short- and long-term reliability as well. In addition, the impact of global signal regression (GSR on reliability of the resting-state language network was investigated, and our results demonstrated that GSR had negligible effect on the temporal reliability of the resting-state language network. Our study provided methodology basis for future cross-culture and clinical researches of resting-state language network and suggested priority of adopting seed-based functional connectivity for its high reliability.
Temporal Reliability and Lateralization of the Resting-State Language Network
Zou, Qihong; Wang, Jue; Gao, Jia-Hong; Niu, Zhendong
2014-01-01
The neural processing loop of language is complex but highly associated with Broca's and Wernicke's areas. The left dominance of these two areas was the earliest observation of brain asymmetry. It was demonstrated that the language network and its functional asymmetry during resting state were reproducible across institutions. However, the temporal reliability of resting-state language network and its functional asymmetry are still short of knowledge. In this study, we established a seed-based resting-state functional connectivity analysis of language network with seed regions located at Broca's and Wernicke's areas, and investigated temporal reliability of language network and its functional asymmetry. The language network was found to be temporally reliable in both short- and long-term. In the aspect of functional asymmetry, the Broca's area was found to be left lateralized, while the Wernicke's area is mainly right lateralized. Functional asymmetry of these two areas revealed high short- and long-term reliability as well. In addition, the impact of global signal regression (GSR) on reliability of the resting-state language network was investigated, and our results demonstrated that GSR had negligible effect on the temporal reliability of the resting-state language network. Our study provided methodology basis for future cross-culture and clinical researches of resting-state language network and suggested priority of adopting seed-based functional connectivity for its high reliability. PMID:24475058
Directory of Open Access Journals (Sweden)
Bengtson Ann
2009-07-01
Full Text Available Abstract Background Symptoms related to atrial fibrillation and their impact on health-related quality of life (HRQoL are often evaluated in clinical trials. However, there remains a need for a properly validated instrument. We aimed to develop and validate a short symptoms scale for patients with AF. Methods One hundred and eleven patients with a variety of symptoms related to AF were scheduled for DC cardioversion. The mean age was 67.1 ± 12.1 years, and 80% were men. The patients completed the new symptoms scale, the Toronto Symptoms Check List (SCL and the generic Short Form 36 (SF-36 the day before the planned DC cardioversion. Compliance was excellent, with only 1 of 666 answers missing. Results One item, 'limitations in working capability', was deleted because of a low numerical response rate, as many of the patients were retired. The internal consistency reliability of the remaining six items was 0.81 (Cronbach's α. Patients scored highest in the items of 'dyspnoea on exertion', 'limitations in daily life due to AF' and 'fatigue due to AF', with scores of 4.5, 3.3 and 4.5, respectively. There was a good correlation to all relevant SF-36 domains and to the relevant questions of the SCL. The Rasch analyses showed that the items are unidimensional and that they are clearly separated and cover an adequate range. Test-retest reliability was performed in patients who failed DC and was adequate for three of six items, >0.70. Conclusion The psychometric characteristics of the new short symptoms scale were found to have satisfactory reliability and validity.
Schretlen, David; And Others
1994-01-01
Composite reliability and standard errors of measurement were computed for prorated Verbal, Performance, and Full-Scale intelligence quotient (IQ) scores from a seven-subtest short form of the Wechsler Adult Intelligence Scale-Revised. Results with 1,880 adults (standardization sample) indicate that this form is as reliable as the complete test.…
Validation of the Short Form of the Career Development Inventory with an Iranian High School Sample
Sadeghi, Ahmad; Baghban, Iran; Bahrami, Fatemeh; Ahmadi, Ahmad; Creed, Peter
2011-01-01
A short 33-item form of the Career Development Inventory was validated on a sample of 310 Iranian high school students. Factor analysis indicated that attitude and cognitive subscale items loaded on their respective factors, and that internal reliability coefficients at all levels were satisfactory to good. Support for validity was demonstrated by…
Reliability and Failure in NASA Missions: Blunders, Normal Accidents, High Reliability, Bad Luck
Jones, Harry W.
2015-01-01
NASA emphasizes crew safety and system reliability but several unfortunate failures have occurred. The Apollo 1 fire was mistakenly unanticipated. After that tragedy, the Apollo program gave much more attention to safety. The Challenger accident revealed that NASA had neglected safety and that management underestimated the high risk of shuttle. Probabilistic Risk Assessment was adopted to provide more accurate failure probabilities for shuttle and other missions. NASA's "faster, better, cheaper" initiative and government procurement reform led to deliberately dismantling traditional reliability engineering. The Columbia tragedy and Mars mission failures followed. Failures can be attributed to blunders, normal accidents, or bad luck. Achieving high reliability is difficult but possible.
Achieving High Reliability with People, Processes, and Technology.
Saunders, Candice L; Brennan, John A
2017-01-01
High reliability as a corporate value in healthcare can be achieved by meeting the "Quadruple Aim" of improving population health, reducing per capita costs, enhancing the patient experience, and improving provider wellness. This drive starts with the board of trustees, CEO, and other senior leaders who ingrain high reliability throughout the organization. At WellStar Health System, the board developed an ambitious goal to become a top-decile health system in safety and quality metrics. To achieve this goal, WellStar has embarked on a journey toward high reliability and has committed to Lean management practices consistent with the Institute for Healthcare Improvement's definition of a high-reliability organization (HRO): one that is committed to the prevention of failure, early identification and mitigation of failure, and redesign of processes based on identifiable failures. In the end, a successful HRO can provide safe, effective, patient- and family-centered, timely, efficient, and equitable care through a convergence of people, processes, and technology.
High power klystrons for efficient reliable high power amplifiers
Levin, M.
1980-11-01
This report covers the design of reliable high efficiency, high power klystrons which may be used in both existing and proposed troposcatter radio systems. High Power (10 kW) klystron designs were generated in C-band (4.4 GHz to 5.0 GHz), S-band (2.5 GHz to 2.7 GHz), and L-band or UHF frequencies (755 MHz to 985 MHz). The tubes were designed for power supply compatibility and use with a vapor/liquid phase heat exchanger. Four (4) S-band tubes were developed in the course of this program along with two (2) matching focusing solenoids and two (2) heat exchangers. These tubes use five (5) tuners with counters which are attached to the focusing solenoids. A reliability mathematical model of the tube and heat exchanger system was also generated.
Wang, Chao; Chen, Peijie; Zhuang, Jie
2013-12-01
The psychometric profiles of the widely used International Physical Activity Questionnaire-Short Form (IPAQ-SF) in Chinese youth have not been reported. The purpose of this study was to examine the validity and reliability of the IPAQ-SF using a sample of Chinese youth. One thousand and twenty-one youth (M(age) = 14.26 +/- 1.63 years, 52.8% boys) from 11 cities in China wore accelerometers for 7 consecutive days and completed the IPAQ-SF on the 8th day to recall their physical activity (PA) during accelerometer-wearing days. A subsample of 92 youth (M(age) = 15.90 +/- 1.35 years, 46.7% boys) completed the IPAQ-SF again a week later to recall their PA during accelerometer-wearing days. Differences in PA estimated by the IPAQ-SF and accelerometer were examined by paired-sample t test. Spearman correlation coefficients were used to examine the correlation between the IPAQ-SF and accelerometer. Test-retest reliability of the IPAQ-SF was determined by the intraclass correlation coefficient (ICC). Compared with accelerometer, the IPAQ-SF overestimated sedentary time, moderate PA (MPA), vigorous PA (VPA), and moderate-to-vigorous PA (MVPA). Correlations between PA (total PA, MPA, VPA, and MVPA) and sedentary time measured by 2 instruments ranged from "none" to "low" (p = .08-.31). Test-retest ICC of the IPAQ-SF ranged from "moderate" to "high" (ICC = .43-.83), except for sitting in boys (ICC = .06), sitting for the whole sample (ICC = .32), and VPA in girls (ICC = .35). The IPAQ-SF was not a valid instrument for measuring PA and sedentary behavior in Chinese youth.
High-reliability computing for the smarter planet
International Nuclear Information System (INIS)
Quinn, Heather M.; Graham, Paul; Manuzzato, Andrea; Dehon, Andre
2010-01-01
The geometric rate of improvement of transistor size and integrated circuit performance, known as Moore's Law, has been an engine of growth for our economy, enabling new products and services, creating new value and wealth, increasing safety, and removing menial tasks from our daily lives. Affordable, highly integrated components have enabled both life-saving technologies and rich entertainment applications. Anti-lock brakes, insulin monitors, and GPS-enabled emergency response systems save lives. Cell phones, internet appliances, virtual worlds, realistic video games, and mp3 players enrich our lives and connect us together. Over the past 40 years of silicon scaling, the increasing capabilities of inexpensive computation have transformed our society through automation and ubiquitous communications. In this paper, we will present the concept of the smarter planet, how reliability failures affect current systems, and methods that can be used to increase the reliable adoption of new automation in the future. We will illustrate these issues using a number of different electronic devices in a couple of different scenarios. Recently IBM has been presenting the idea of a 'smarter planet.' In smarter planet documents, IBM discusses increased computer automation of roadways, banking, healthcare, and infrastructure, as automation could create more efficient systems. A necessary component of the smarter planet concept is to ensure that these new systems have very high reliability. Even extremely rare reliability problems can easily escalate to problematic scenarios when implemented at very large scales. For life-critical systems, such as automobiles, infrastructure, medical implantables, and avionic systems, unmitigated failures could be dangerous. As more automation moves into these types of critical systems, reliability failures will need to be managed. As computer automation continues to increase in our society, the need for greater radiation reliability is necessary
High-reliability computing for the smarter planet
Energy Technology Data Exchange (ETDEWEB)
Quinn, Heather M [Los Alamos National Laboratory; Graham, Paul [Los Alamos National Laboratory; Manuzzato, Andrea [UNIV OF PADOVA; Dehon, Andre [UNIV OF PENN; Carter, Nicholas [INTEL CORPORATION
2010-01-01
The geometric rate of improvement of transistor size and integrated circuit performance, known as Moore's Law, has been an engine of growth for our economy, enabling new products and services, creating new value and wealth, increasing safety, and removing menial tasks from our daily lives. Affordable, highly integrated components have enabled both life-saving technologies and rich entertainment applications. Anti-lock brakes, insulin monitors, and GPS-enabled emergency response systems save lives. Cell phones, internet appliances, virtual worlds, realistic video games, and mp3 players enrich our lives and connect us together. Over the past 40 years of silicon scaling, the increasing capabilities of inexpensive computation have transformed our society through automation and ubiquitous communications. In this paper, we will present the concept of the smarter planet, how reliability failures affect current systems, and methods that can be used to increase the reliable adoption of new automation in the future. We will illustrate these issues using a number of different electronic devices in a couple of different scenarios. Recently IBM has been presenting the idea of a 'smarter planet.' In smarter planet documents, IBM discusses increased computer automation of roadways, banking, healthcare, and infrastructure, as automation could create more efficient systems. A necessary component of the smarter planet concept is to ensure that these new systems have very high reliability. Even extremely rare reliability problems can easily escalate to problematic scenarios when implemented at very large scales. For life-critical systems, such as automobiles, infrastructure, medical implantables, and avionic systems, unmitigated failures could be dangerous. As more automation moves into these types of critical systems, reliability failures will need to be managed. As computer automation continues to increase in our society, the need for greater radiation reliability is
Dodeen, Hamzeh
2013-01-01
Students' opinions continue to be a significant factor in the evaluation of teaching in higher education institutions. The purpose of this study was to psychometrically assess short students evaluation of teaching (SET) forms using the UAE University form as a model. The study evaluated the form validity, reliability, the overall question, and…
Column Grid Array Rework for High Reliability
Mehta, Atul C.; Bodie, Charles C.
2008-01-01
Due to requirements for reduced size and weight, use of grid array packages in space applications has become common place. To meet the requirement of high reliability and high number of I/Os, ceramic column grid array packages (CCGA) were selected for major electronic components used in next MARS Rover mission (specifically high density Field Programmable Gate Arrays). ABSTRACT The probability of removal and replacement of these devices on the actual flight printed wiring board assemblies is deemed to be very high because of last minute discoveries in final test which will dictate changes in the firmware. The questions and challenges presented to the manufacturing organizations engaged in the production of high reliability electronic assemblies are, Is the reliability of the PWBA adversely affected by rework (removal and replacement) of the CGA package? and How many times can we rework the same board without destroying a pad or degrading the lifetime of the assembly? To answer these questions, the most complex printed wiring board assembly used by the project was chosen to be used as the test vehicle, the PWB was modified to provide a daisy chain pattern, and a number of bare PWB s were acquired to this modified design. Non-functional 624 pin CGA packages with internal daisy chained matching the pattern on the PWB were procured. The combination of the modified PWB and the daisy chained packages enables continuity measurements of every soldered contact during subsequent testing and thermal cycling. Several test vehicles boards were assembled, reworked and then thermal cycled to assess the reliability of the solder joints and board material including pads and traces near the CGA. The details of rework process and results of thermal cycling are presented in this paper.
DEFF Research Database (Denmark)
Pakpour, Amir; Yekaninejad, Mirsaeed; Mølsted, Stig
2011-01-01
AIM: The aims of the study were to translate the Kidney Disease Quality of Life--Short Form version 1.3 (KDQOL-SF ver. 1.3) questionnaire into Iranian (Farsi), and to then assess it in terms of validity and reliability on Iranian patients. METHODS: The questionnaire was first translated into Farsi...... a larger group (212 patients with end-stage renal disease on haemodialysis). Afterwards, reliability was estimated by internal consistency, and validity was assessed using known group comparisons and constructs for the patient group as a whole. Finally, the factor structure of the questionnaire...... be summarized into an 11 factor structure that jointly accounted for 79.81% of the variance. CONCLUSION: The Iranian version of the KDQOL-SF questionnaire is both highly reliable and valid for use with Iranian patients on haemodialysis....
Delivering high performance BWR fuel reliably
International Nuclear Information System (INIS)
Schardt, J.F.
1998-01-01
Utilities are under intense pressure to reduce their production costs in order to compete in the increasingly deregulated marketplace. They need fuel, which can deliver high performance to meet demanding operating strategies. GE's latest BWR fuel design, GE14, provides that high performance capability. GE's product introduction process assures that this performance will be delivered reliably, with little risk to the utility. (author)
Highly reliable electro-hydraulic control system
International Nuclear Information System (INIS)
Mande, Morima; Hiyama, Hiroshi; Takahashi, Makoto
1984-01-01
The unscheduled shutdown of nuclear power stations disturbs power system, and exerts large influence on power generation cost due to the lowering of capacity ratio; therefore, high reliability is required for the control system of nuclear power stations. Toshiba Corp. has exerted effort to improve the reliability of the control system of power stations, and in this report, the electro-hydraulic control system for the turbines of nuclear power stations is described. The main functions of the electro-hydraulic control system are the control of main steam pressure with steam regulation valves and turbine bypass valves, the control of turbine speed and load, the prevention of turbine overspeed, the protection of turbines and so on. The system is composed of pressure sensors and a speed sensor, the control board containing the electronic circuits for control computation and protective sequence, the oil cylinders, servo valves and opening detectors of the valves for control, a high pressure oil hydraulic machine and piping, the operating panel and so on. The main features are the adoption of tripling intermediate value selection method, the multiplying of protection sensors and the adoption of 2 out of 3 trip logic, the multiplying of power sources, the improvement of the reliability of electronic circuit hardware and oil hydraulic system. (Kako, I.)
Extremera, Natalio; Fernández-Berrocal, Pablo
2006-02-01
This study investigated the construct validity and reliability of the Spanish Ruminative Responses Scale-Short From, and the Distraction Responses Scale of the Response Styles Questionnaire for a sample of 727 Spanish high school and college students who responded anonymously and voluntarily to a questionnaire (293 men, 434 women; ages 16 to 29 years, M=18.8, SD=3.0). In addition to the above scales, the questionnaire included the Spanish forms of the Beck Depression Inventory, the Trait Anxiety Scale from the State-Trait Anxiety Scale, the Satisfaction with Life Scale, and the Subjective Happiness Scale. The internal consistency of the scales was satisfactory (Cronbach alpha=.86 for the Ruminative Responses Scale and .78 for the Distraction Responses Scale). As expected, scores on the Spanish Ruminative Responses Scale showed positive correlations with those on the Beck Depression Inventory and the Trait Anxiety Scale and negative associations with the Satisfaction with Life Scale and the Subjective Happiness Scale. Conversely, the Spanish Distraction Responses Scale was negatively correlated with the Beck Depression Inventory and positively associated with the Satisfaction with Life Scale and the Subjective Happiness Scale. These results provide evidence of appropriate reliability for research purposes. Furthermore, the correlational analysis supported prior findings that ruminative response and distraction response styles are differentially associated with reported depressed and positive moods.
Delivering high performance BWR fuel reliably
Energy Technology Data Exchange (ETDEWEB)
Schardt, J.F. [GE Nuclear Energy, Wilmington, NC (United States)
1998-07-01
Utilities are under intense pressure to reduce their production costs in order to compete in the increasingly deregulated marketplace. They need fuel, which can deliver high performance to meet demanding operating strategies. GE's latest BWR fuel design, GE14, provides that high performance capability. GE's product introduction process assures that this performance will be delivered reliably, with little risk to the utility. (author)
Morpho-Functional 1H-MRI of the Lung in COPD: Short-Term Test-Retest Reliability.
Directory of Open Access Journals (Sweden)
Bertram J Jobst
MRI1 (276 of 278 and MRI2 (259 of 264.Morpho-functional 1H-MRI can be obtained with reproducible image quality and high short-term test-retest reliability for COPD-related morphological and functional changes of the lung. This underlines its potential value for the monitoring of regional lung characteristics in COPD trials.
Al Hassan, Mohammad; Britton, Paul; Hatfield, Glen Spencer; Novack, Steven D.
2017-01-01
Field Programmable Gate Arrays (FPGAs) integrated circuits (IC) are one of the key electronic components in today's sophisticated launch and space vehicle complex avionic systems, largely due to their superb reprogrammable and reconfigurable capabilities combined with relatively low non-recurring engineering costs (NRE) and short design cycle. Consequently, FPGAs are prevalent ICs in communication protocols and control signal commands. This paper will identify reliability concerns and high level guidelines to estimate FPGA total failure rates in a launch vehicle application. The paper will discuss hardware, hardware description language, and radiation induced failures. The hardware contribution of the approach accounts for physical failures of the IC. The hardware description language portion will discuss the high level FPGA programming languages and software/code reliability growth. The radiation portion will discuss FPGA susceptibility to space environment radiation.
Kumar, Santhosh; Kroon, Jeroen; Lalloo, Ratilal; Johnson, Newell W
2016-03-01
Parental-Caregiver Perception Questionnaire (P-CPQ) and Family Impact Scale (FIS) are commonly used measures to evaluate the parent's perception of the impact of children's oral health on quality of life and family respectively. Recently, shorter forms of P-CPQ and FIS have been developed. No study has sought to validate these short forms in other languages and cultures. This study aimed to evaluate the validity and reliability of FIS, 8 and 16-item P-CPQ in a Telugu speaking population of India. For this cross-sectional study, a multi-stage random sampling technique was used to recruit 11-13 year-old schoolchildren of Medak district, Telangana, India and their parents (n = 1342). Parents were approached with questionnaires through their children who underwent clinical examinations for dental caries, fluorosis and malocclusion. The translated versions underwent pilot testing (n = 40), test-retest reliability was also assessed (n = 161). The overall summary scale and subscales of the short forms of P-CPQ and FIS failed to discriminate between the categories of dental caries severity. Also, malocclusion status was not related to the domain or overall scores of both the short forms of P-CPQ. There were significant differences in subscale and overall scores of 16 and 8-item P-CPQ and FIS between the fluorosis categories. Both 16 and 8-item P-CPQ summary scales were significantly related to parent's global rating of oral health (16-item, r = 0.30, p internal consistency and reliability on repeated administrations.
Directory of Open Access Journals (Sweden)
Sangmi Kim
Full Text Available Studies examining the association between telomere length and cancer risk have often relied on measurement of telomere length from a single blood draw using a real-time PCR technique. We examined the reliability of telomere length measurement using sequential samples collected over a 9-month period.Relative telomere length in peripheral blood was estimated using a single tube monochrome multiplex quantitative PCR assay in blood DNA samples from 27 non-pregnant adult women (aged 35 to 74 years collected in 7 visits over a 9-month period. A linear mixed model was used to estimate the components of variance for telomere length measurements attributed to variation among women and variation between time points within women. Mean telomere length measurement at any single visit was not significantly different from the average of 7 visits. Plates had a significant systematic influence on telomere length measurements, although measurements between different plates were highly correlated. After controlling for plate effects, 64% of the remaining variance was estimated to be accounted for by variance due to subject. Variance explained by time of visit within a subject was minor, contributing 5% of the remaining variance.Our data demonstrate good short-term reliability of telomere length measurement using blood from a single draw. However, the existence of technical variability, particularly plate effects, reinforces the need for technical replicates and balancing of case and control samples across plates.
Custom high-reliability radiation-hard CMOS-LSI circuit design
International Nuclear Information System (INIS)
Barnard, W.J.
1981-01-01
Sandia has developed a custom CMOS-LSI design capability to provide high reliability radiation-hardened circuits. This capability relies on (1) proven design practices to enhance reliability, (2) use of well characterized cells and logic modules, (3) computer-aided design tools to reduce design time and errors and to standardize design definition, and (4) close working relationships with the system designer and technology fabrication personnel. Trade-offs are made during the design between circuit complexity/performance and technology/producibility for high reliability and radiation-hardened designs to result. Sandia has developed and is maintaining a radiation-hardened bulk CMOS technology fabrication line for production of prototype and small production volume parts
High Reliability Oscillators for Terahertz Systems, Phase II
National Aeronautics and Space Administration — To develop reliable THz sources with high power and high DC-RF efficiency, Virginia Diodes, Inc. will develop a thorough understanding of the complex interactions...
Assessment of microelectronics packaging for high temperature, high reliability applications
Energy Technology Data Exchange (ETDEWEB)
Uribe, F.
1997-04-01
This report details characterization and development activities in electronic packaging for high temperature applications. This project was conducted through a Department of Energy sponsored Cooperative Research and Development Agreement between Sandia National Laboratories and General Motors. Even though the target application of this collaborative effort is an automotive electronic throttle control system which would be located in the engine compartment, results of this work are directly applicable to Sandia`s national security mission. The component count associated with the throttle control dictates the use of high density packaging not offered by conventional surface mount. An enabling packaging technology was selected and thermal models defined which characterized the thermal and mechanical response of the throttle control module. These models were used to optimize thick film multichip module design, characterize the thermal signatures of the electronic components inside the module, and to determine the temperature field and resulting thermal stresses under conditions that may be encountered during the operational life of the throttle control module. Because the need to use unpackaged devices limits the level of testing that can be performed either at the wafer level or as individual dice, an approach to assure a high level of reliability of the unpackaged components was formulated. Component assembly and interconnect technologies were also evaluated and characterized for high temperature applications. Electrical, mechanical and chemical characterizations of enabling die and component attach technologies were performed. Additionally, studies were conducted to assess the performance and reliability of gold and aluminum wire bonding to thick film conductor inks. Kinetic models were developed and validated to estimate wire bond reliability.
Yu, Long; Xu, Juanjuan; Zhang, Lifang; Xu, Xiaogang
2018-03-01
Based on stress-strength interference theory to establish the reliability mathematical model for high temperature and high pressure multi-stage decompression control valve (HMDCV), and introduced to the temperature correction coefficient for revising material fatigue limit at high temperature. Reliability of key dangerous components and fatigue sensitivity curve of each component are calculated and analyzed by the means, which are analyzed the fatigue life of control valve and combined with reliability theory of control valve model. The impact proportion of each component on the control valve system fatigue failure was obtained. The results is shown that temperature correction factor makes the theoretical calculations of reliability more accurate, prediction life expectancy of main pressure parts accords with the technical requirements, and valve body and the sleeve have obvious influence on control system reliability, the stress concentration in key part of control valve can be reduced in the design process by improving structure.
High-energy, short-pulse, carbon-dioxide lasers
International Nuclear Information System (INIS)
Fenstermacher, C.A.
1979-01-01
Lasers for fusion application represent a special class of short-pulse generators; not only must they generate extremely short temporal pulses of high quality, but they must do this at ultra-high powers and satisfy other stringent requirements by this application. This paper presents the status of the research and development of carbon-dioxide laser systems at the Los Alamos Scientific Laboratory, vis-a-vis the fusion requirements
Valen, Jakob; Ryum, Truls; Svartberg, Martin; Stiles, Tore C.; McCullough, Leigh
2011-01-01
This study examined interrater reliability and sensitivity to change of the Achievement of Therapeutic Objectives Scale (ATOS; McCullough, Larsen, et al., 2003) in short-term dynamic psychotherapy (STDP) and cognitive therapy (CT). The ATOS is a process scale originally developed to assess patients' achievements of treatment objectives in STDP,…
Reliability & availability of wind turbine electrical & electronic components
Tavner, P.; Faulstich, S.; Hahn, B.; Bussel, van G.J.W.
2010-01-01
Recent analysis of European onshore wind turbine reliability data has shown that whilst wind turbine mechanical subassemblies tend to have relatively low failure rates but long downtimes, electrical and electronic subassemblies have relatively high failure rates and short downtimes. For onshore wind
High reliability low jitter 80 kV pulse generator
International Nuclear Information System (INIS)
Savage, Mark Edward; Stoltzfus, Brian Scott
2009-01-01
Switching can be considered to be the essence of pulsed power. Time accurate switch/trigger systems with low inductance are useful in many applications. This article describes a unique switch geometry coupled with a low-inductance capacitive energy store. The system provides a fast-rising high voltage pulse into a low impedance load. It can be challenging to generate high voltage (more than 50 kilovolts) into impedances less than 10 (Omega), from a low voltage control signal with a fast rise time and high temporal accuracy. The required power amplification is large, and is usually accomplished with multiple stages. The multiple stages can adversely affect the temporal accuracy and the reliability of the system. In the present application, a highly reliable and low jitter trigger generator was required for the Z pulsed-power facility [M. E. Savage, L. F. Bennett, D. E. Bliss, W. T. Clark, R. S. Coats,J. M. Elizondo, K. R. LeChien, H. C. Harjes, J. M. Lehr, J. E. Maenchen, D. H. McDaniel, M. F. Pasik, T. D. Pointon, A. C. Owen, D. B. Seidel, D. L. Smith, B. S. Stoltzfus, K.W. Struve, W.A. Stygar, L.K. Warne, and J. R. Woodworth, 2007 IEEE Pulsed Power Conference, Albuquerque, NM (IEEE, Piscataway, NJ, 2007), p. 979]. The large investment in each Z experiment demands low prefire probability and low jitter simultaneously. The system described here is based on a 100 kV DC-charged high-pressure spark gap, triggered with an ultraviolet laser. The system uses a single optical path for simultaneously triggering two parallel switches, allowing lower inductance and electrode erosion with a simple optical system. Performance of the system includes 6 ns output rise time into 5.6 (Omega), 550 ps one-sigma jitter measured from the 5 V trigger to the high voltage output, and misfire probability less than 10 -4 . The design of the system and some key measurements will be shown in the paper. We will discuss the design goals related to high reliability and low jitter. While
Memorial Hermann: high reliability from board to bedside.
Shabot, M Michael; Monroe, Douglas; Inurria, Juan; Garbade, Debbi; France, Anne-Claire
2013-06-01
In 2006 the Memorial Hermann Health System (MHHS), which includes 12 hospitals, began applying principles embraced by high reliability organizations (HROs). Three factors support its HRO journey: (1) aligned organizational structure with transparent management systems and compressed reporting processes; (2) Robust Process Improvement (RPI) with high-reliability interventions; and (3) cultural establishment, sustainment, and evolution. The Quality and Safety strategic plan contains three domains, each with a specific set of measures that provide goals for performance: (1) "Clinical Excellence;" (2) "Do No Harm;" and (3) "Saving Lives," as measured by the Serious Safety Event rate. MHHS uses a uniform approach to performance improvement--RPI, which includes Six Sigma, Lean, and change management, to solve difficult safety and quality problems. The 9 acute care hospitals provide multiple opportunities to integrate high-reliability interventions and best practices across MHHS. For example, MHHS partnered with the Joint Commission Center for Transforming Healthcare in its inaugural project to establish reliable hand hygiene behaviors, which improved MHHS's average hand hygiene compliance rate from 44% to 92% currently. Soon after compliance exceeded 85% at all 12 hospitals, the average rate of central line-associated bloodstream and ventilator-associated pneumonias decreased to essentially zero. MHHS's size and diversity require a disciplined approach to performance improvement and systemwide achievement of measurable success. The most significant cultural change at MHHS has been the expectation for 100% compliance with evidence-based quality measures and 0% incidence of patient harm.
A new kind high-reliability digital reactivity meter
International Nuclear Information System (INIS)
Shen Feng; Jiang Zongbing
2001-01-01
The paper introduces a new kind of high-reliability Digital Reactivity Meter developed by the DRM developing group in designing department of Nuclear Power Institute of China. The meter has two independent measure channels, which can be set as either master-slave structure or working independently. This structure will ensure that the meter can continually fulfill its online measure task under the condition of single failure with it. It provides a solution for the conflict between nuclear station's extreme demand in DRM's reliability and instability of computer's business software platform. The instrument reaches both advance and reliability by covering a lot of kinds of complex functions in data process and display
Sfendla, Anis; Laita, Meriame; Nejjar, Basma; Souirti, Zouhayr; Touhami, Ahami Ahmed Omar; Senhaji, Meftaha
2018-05-01
The extensive accessibility to smartphones in the last decade raises the concerns of addictive behavior patterns toward these technologies worldwide and in developing countries, and Arabic ones in particular. In an area of stigmatized behavior such as Internet and smartphone addiction, the hypothesis extends to whether there is a reliable instrument that can assess smartphone addiction. To our knowledge, no scale in Arabic language is available to assess maladaptive behavior associated with smartphone use. This study aims to assess the factorial validity and internal reliability of the Arabic Smartphone Addiction Scale (SAS) and Smartphone Addiction Scale-Short Version (SAS-SV) in a Moroccan surveyed population. Participants (N = 440 and N = 310) completed an online survey, including SAS, SAS-SV, and questions about sociodemographic status. Factor analysis results showed six factors with factor loading ranging from 0.25 to 0.99 for SAS. Reliability, based on Cronbach's alpha, was excellent (α = 0.94) for this instrument. The SAS-SV showed one factor (unidimensional construct), and internal reliability was in the good range with an alpha coefficient of (α = 0.87). The prevalence of excessive users was 55.8 percent with highest symptom prevalence reported for tolerance and preoccupation. This study proved factor validity of the Arabic SAS and SAS-SV instruments and confirmed their internal reliability.
Reliability and validity of the Japanese version of the Resilience Scale and its short version.
Nishi, Daisuke; Uehara, Ritei; Kondo, Maki; Matsuoka, Yutaka
2010-11-17
The clinical relevance of resilience has received considerable attention in recent years. The aim of this study is to demonstrate the reliability and validity of the Japanese version of the Resilience Scale (RS) and short version of the RS (RS-14). The original English version of RS was translated to Japanese and the Japanese version was confirmed by back-translation. Participants were 430 nursing and university psychology students. The RS, Center for Epidemiologic Studies Depression Scale (CES-D), Rosenberg Self-Esteem Scale (RSES), Social Support Questionnaire (SSQ), Perceived Stress Scale (PSS), and Sheehan Disability Scale (SDS) were administered. Internal consistency, convergent validity and factor loadings were assessed at initial assessment. Test-retest reliability was assessed using data collected from 107 students at 3 months after baseline. Mean score on the RS was 111.19. Cronbach's alpha coefficients for the RS and RS-14 were 0.90 and 0.88, respectively. The test-retest correlation coefficients for the RS and RS-14 were 0.83 and 0.84, respectively. Both the RS and RS-14 were negatively correlated with the CES-D and SDS, and positively correlated with the RSES, SSQ and PSS (all p reliability, and relatively low concurrent validity. RS-14 was equivalent to the RS in internal consistency, test-retest reliability, and concurrent validity. Low scores on the RS, a positive correlation between the RS and perceived stress, and a relatively low correlation between the RS and depressive symptoms in this study suggest that validity of the Japanese version of the RS might be relatively low compared with the original English version.
Simple and reliable procedure for the evaluation of short-term dynamic processes in power systems
Energy Technology Data Exchange (ETDEWEB)
Popovic, D P
1986-10-01
An efficient approach is presented to the solution of the short-term dynamics model in power systems. It consists of an adequate algebraic treatment of the original system of nonlinear differential equations, using linearization, decomposition and Cauchy's formula. The simple difference equations obtained in this way are incorporated into a model of the electrical network, which is of a low order compared to the ones usually used. Newton's method is applied to the model formed in this way, which leads to a simple and reliable iterative procedure. The characteristics of the procedure developed are demonstrated on examples of transient stability analysis of real power systems. 12 refs.
Directory of Open Access Journals (Sweden)
Corey J. Hayes
2017-04-01
Full Text Available Limited evidence exists on how non-cancer pain (NCP affects an individual’s health-related quality of life (HRQoL. This study aimed to validate the Medical Outcomes Study Short Form-12 Version 2 (SF-12v2, a generic measure of HRQoL, in a NCP cohort using the Medical Expenditure Panel Survey Longitudinal Files. The SF Mental Component Summary (MCS12 and SF Physical Component Summary (PCS12 were tested for reliability (internal consistency and test-retest reliability and validity (construct: convergent and discriminant; criterion: concurrent and predictive. A total of 15,716 patients with NCP were included in the final analysis. The MCS12 and PCS12 demonstrated high internal consistency (Cronbach’s alpha and Mosier’s alpha > 0.8, and moderate and high test-retest reliability, respectively (MCS12 intraclass correlation coefficient (ICC: 0.64; PCS12 ICC: 0.73. Both scales were significantly associated with a number of chronic conditions (p < 0.05. The PCS12 was strongly correlated with perceived health (r = 0.52 but weakly correlated with perceived mental health (r = 0.25. The MCS12 was moderately correlated with perceived mental health (r = 0.42 and perceived health (r = 0.33. Increasing PCS12 and MCS12 scores were significantly associated with lower odds of reporting future physical and cognitive limitations (PCS12: OR = 0.90 95%CI: 0.89–0.90, MCS12: OR = 0.94 95%CI: 0.93–0.94. In summary, the SF-12v2 is a reliable and valid measure of HRQoL for patients with NCP.
Development of high-reliability control system for nuclear power plants
International Nuclear Information System (INIS)
Asami, K.; Yanai, K.; Hirose, H.; Ito, T.
1983-01-01
In Japan, many nuclear power generating plants are in operation and under construction. There is a general awareness of the problems in connection with nuclear power generation and strong emphasis is put on achieving highly reliable operation of nuclear power plants. Hitachi has developed a new high-reliability control system. NURECS-3000 (NUclear Power Plant High-REliability Control System), which is applied to the main control systems, such as the reactor feedwater control system, the reactor recirculation control system and the main turbine control system. The NURECS-3000 system was designed taking into account the fact that there will be failures, but the aim is for the system to continue to function correctly; it is therefore a fault-tolerant system. It has redundant components which can be completely isolated from each other in order to prevent fault propagation. The system has a hierarchical configuration, with a main controller, consisting of a triplex microcomputer system, and sub-loop controllers. Special care was taken to ensure the independence of these subsystems. Since most of the redundant system failures are caused by common-mode failures and the reliability of redundant systems depends on the reliability of the common-mode parts, the aim was to minimize these parts. (author)
High reliability megawatt transformer/rectifier
Zwass, Samuel; Ashe, Harry; Peters, John W.
1991-01-01
The goal of the two phase program is to develop the technology and design and fabricate ultralightweight high reliability DC to DC converters for space power applications. The converters will operate from a 5000 V dc source and deliver 1 MW of power at 100 kV dc. The power weight density goal is 0.1 kg/kW. The cycle to cycle voltage stability goals was + or - 1 percent RMS. The converter is to operate at an ambient temperature of -40 C with 16 minute power pulses and one hour off time. The uniqueness of the design in Phase 1 resided in the dc switching array which operates the converter at 20 kHz using Hollotron plasma switches along with a specially designed low loss, low leakage inductance and a light weight high voltage transformer. This approach reduced considerably the number of components in the converter thereby increasing the system reliability. To achieve an optimum transformer for this application, the design uses four 25 kV secondary windings to produce the 100 kV dc output, thus reducing the transformer leakage inductance, and the ac voltage stresses. A specially designed insulation system improves the high voltage dielectric withstanding ability and reduces the insulation path thickness thereby reducing the component weight. Tradeoff studies and tests conducted on scaled-down model circuits and using representative coil insulation paths have verified the calculated transformer wave shape parameters and the insulation system safety. In Phase 1 of the program a converter design approach was developed and a preliminary transformer design was completed. A fault control circuit was designed and a thermal profile of the converter was also developed.
Achieving High Reliability Operations Through Multi-Program Integration
Energy Technology Data Exchange (ETDEWEB)
Holly M. Ashley; Ronald K. Farris; Robert E. Richards
2009-04-01
Over the last 20 years the Idaho National Laboratory (INL) has adopted a number of operations and safety-related programs which has each periodically taken its turn in the limelight. As new programs have come along there has been natural competition for resources, focus and commitment. In the last few years, the INL has made real progress in integrating all these programs and are starting to realize important synergies. Contributing to this integration are both collaborative individuals and an emerging shared vision and goal of the INL fully maturing in its high reliability operations. This goal is so powerful because the concept of high reliability operations (and the resulting organizations) is a masterful amalgam and orchestrator of the best of all the participating programs (i.e. conduct of operations, behavior based safety, human performance, voluntary protection, quality assurance, and integrated safety management). This paper is a brief recounting of the lessons learned, thus far, at the INL in bringing previously competing programs into harmony under the goal (umbrella) of seeking to perform regularly as a high reliability organization. In addition to a brief diagram-illustrated historical review, the authors will share the INL’s primary successes (things already effectively stopped or started) and the gaps yet to be bridged.
High Reliability Cryogenic Piezoelectric Valve Actuator, Phase II
National Aeronautics and Space Administration — Cryogenic fluid valves are subject to harsh exposure and actuators to drive these valves require robust performance and high reliability. DSM's piezoelectric...
Sidor, Anna; Cierpka, Manfred
2016-01-01
A standardized assessment of a family system plays a crucial role in family therapy research and diagnostic, as well as in a family therapy itself. A 14-item short version of the General Family Questionnaire (FB-K) was designed to get a tool for assessing family functionality that is low time-consuming. The short version was developed by factor analysis from the long version FA-A. The quality criteria of the family questionnaire were verified in a control sample of 208 high-risk families four months after the birth of their child. The new family questionnaire demonstrates a very good reliability and a satisfactory 8-months-stability. The concurrent validity with the FACES scale "cohesion" is assured. Regarding the construct validity a positive correlation to the feeling of coherence was found. The family questionnaire shows a negative correlation to the maternal postnatal depressive symptoms, the degree of maternal stress burden, the dysfunctionality of the mother-child-relationship and impaired bonding. The values taken from a norm sample with infants are higher by trend and in the sample with children under 18 do not deviate from the values of the risk sample. FB-K covers two aspects of family functioning, the bond between family members and their willingness to communicate. The internal consistency of FB-K is excellent, the criterion and the construct validity are good.
Weertman, A; ArntZ, A; Dreessen, L; van Velzen, C; Vertommen, S
2003-01-01
This study examined the short-interval test-retest reliability of the Structured Clinical Interview (SCID-II: First, Spitzer, Gibbon, & Williams, 1995) for DSM-IV personality disorders (PDs). The SCID-II was administered to 69 in- and outpatients on two occasions separated by 1 to 6 weeks. The
High-Reliable PLC RTOS Development and RPS Structure Analysis
Energy Technology Data Exchange (ETDEWEB)
Sohn, H. S.; Song, D. Y.; Sohn, D. S.; Kim, J. H. [Enersys Co., Daejeon (Korea, Republic of)
2008-04-15
One of the KNICS objectives is to develop a platform for Nuclear Power Plant(NPP) I and C(Instrumentation and Control) system, especially plant protection system. The developed platform is POSAFE-Q and this work supports the development of POSAFE-Q with the development of high-reliable real-time operating system(RTOS) and programmable logic device(PLD) software. Another KNICS objective is to develop safety I and C systems, such as Reactor Protection System(RPS) and Engineered Safety Feature-Component Control System(ESF-CCS). This work plays an important role in the structure analysis for RPS. Validation and verification(V and V) of the safety critical software is an essential work to make digital plant protection system highly reliable and safe. Generally, the reliability and safety of software based system can be improved by strict quality assurance framework including the software development itself. In other words, through V and V, the reliability and safety of a system can be improved and the development activities like software requirement specification, software design specification, component tests, integration tests, and system tests shall be appropriately documented for V and V.
High-Reliable PLC RTOS Development and RPS Structure Analysis
International Nuclear Information System (INIS)
Sohn, H. S.; Song, D. Y.; Sohn, D. S.; Kim, J. H.
2008-04-01
One of the KNICS objectives is to develop a platform for Nuclear Power Plant(NPP) I and C(Instrumentation and Control) system, especially plant protection system. The developed platform is POSAFE-Q and this work supports the development of POSAFE-Q with the development of high-reliable real-time operating system(RTOS) and programmable logic device(PLD) software. Another KNICS objective is to develop safety I and C systems, such as Reactor Protection System(RPS) and Engineered Safety Feature-Component Control System(ESF-CCS). This work plays an important role in the structure analysis for RPS. Validation and verification(V and V) of the safety critical software is an essential work to make digital plant protection system highly reliable and safe. Generally, the reliability and safety of software based system can be improved by strict quality assurance framework including the software development itself. In other words, through V and V, the reliability and safety of a system can be improved and the development activities like software requirement specification, software design specification, component tests, integration tests, and system tests shall be appropriately documented for V and V.
High beam quality and high energy short-pulse laser with MOPA
Jin, Quanwei; Pang, Yu; Jiang, JianFeng; Tan, Liang; Cui, Lingling; Wei, Bin; Sun, Yinhong; Tang, Chun
2018-03-01
A high energy, high beam quality short-pulse diode-pumped Nd:YAG master oscillator power-amplifier (MOPA) laser with two amplifier stages is demonstrated. The two-rod birefringence compensation was used as beam quality controlling methods, which presents a short-pulse energy of 40 mJ with a beam quality value of M2 = 1.2 at a repetition rate of 400Hz. The MOPA system delivers a short-pulse energy of 712.5 mJ with a pulse width of 12.4 ns.The method of spherical aberration compensation is improved the beam quality, a M2 factor of 2.3 and an optical-to-optical efficiency of 27.7% is obtained at the maximum laser out power.The laser obtained 1.4J out energy with polarization integration.
High pressure, high current, low inductance, high reliability sealed terminals
Hsu, John S [Oak Ridge, TN; McKeever, John W [Oak Ridge, TN
2010-03-23
The invention is a terminal assembly having a casing with at least one delivery tapered-cone conductor and at least one return tapered-cone conductor routed there-through. The delivery and return tapered-cone conductors are electrically isolated from each other and positioned in the annuluses of ordered concentric cones at an off-normal angle. The tapered cone conductor service can be AC phase conductors and DC link conductors. The center core has at least one service conduit of gate signal leads, diagnostic signal wires, and refrigerant tubing routed there-through. A seal material is in direct contact with the casing inner surface, the tapered-cone conductors, and the service conduits thereby hermetically filling the interstitial space in the casing interior core and center core. The assembly provides simultaneous high-current, high-pressure, low-inductance, and high-reliability service.
Human reliability in high dose rate afterloading radiotherapy based on FMECA
International Nuclear Information System (INIS)
Deng Jun; Fan Yaohua; Yue Baorong; Wei Kedao; Ren Fuli
2012-01-01
Objective: To put forward reasonable and feasible recommendations against the procedure with relative high risk during the high dose rate (HDR) afterloading radiotherapy, so as to enhance its clinical application safety, through studying the human reliability in the process of carrying out the HDR afterloading radiotherapy. Methods: Basic data were collected by on-site investigation and process analysis as well as expert evaluation. Failure mode, effect and criticality analysis (FMECA) employed to study the human reliability in the execution of HDR afterloading radiotherapy. Results: The FMECA model of human reliability for HDR afterloading radiotherapy was established, through which 25 procedures with relative high risk index were found,accounting for 14.1% of total 177 procedures. Conclusions: FMECA method in human reliability study for HDR afterloading radiotherapy is feasible. The countermeasures are put forward to reduce the human error, so as to provide important basis for enhancing clinical application safety of HDR afterloading radiotherapy. (authors)
Reliability studies of high operating temperature MCT photoconductor detectors
Wang, Wei; Xu, Jintong; Zhang, Yan; Li, Xiangyang
2010-10-01
This paper concerns HgCdTe (MCT) infrared photoconductor detectors with high operating temperature. The near room temperature operation of detectors have advantages of light weight, less cost and convenient usage. Their performances are modest and they suffer from reliable problems. These detectors face with stability of the package, chip bonding area and passivation layers. It's important to evaluate and improve the reliability of such detectors. Defective detectors were studied with SEM(Scanning electron microscope) and microscopy. Statistically significant differences were observed between the influence of operating temperature and the influence of humidity. It was also found that humility has statistically significant influence upon the stability of the chip bonding and passivation layers, and the amount of humility isn't strongly correlated to the damage on the surface. Considering about the commonly found failures modes in detectors, special test structures were designed to improve the reliability of detectors. An accelerated life test was also implemented to estimate the lifetime of the high operating temperature MCT photoconductor detectors.
RELIABILITY AND ACCURACY OF 10 HZ GPS DEVICES FOR SHORT-DISTANCE EXERCISE
Directory of Open Access Journals (Sweden)
Julen Castellano
2011-03-01
al., 2009. Logan Plus v.4.0 software was used to synchronize the GPS files with the video, establishing the beginning of action when the participant crossed the initial photocell; this was then added to the duration obtained through the photoelectric cells.The accuracy of data within and between devices is shown in Table 1. The average values are close to those established in tests of 15 m and 30 m, with errors getting smaller when the devices were used over 30 m.The intra-device reliability is depicted in Figure 1, showing greater stability over 30 m than 15 m. The inter-device reliability yielded a CV = 1.3% and CV = 0.7% for sprints over 15 m and 30 m, respectively.To our knowledge this is the first study to assess the reliability and accuracy of GPS devices operating at a sampling frequency of 10 Hz. A further point of note is that studies of intra- and inter-device reliability for the same model of device (and therefore the same sampling rate have traditionally used only two devices (Duffield et al., 2010; Petersen et al., 2009, whereas here a total of nine devices were studied.The distance data were found to be highly accurate and only slightly underestimated by the GPS devices. Furthermore, high intra- and inter-device reliability was observed. Accuracy improved with increased distance, and the mean SEM of 10.9% when running 15 m was reduced by half over 30 m (Table 1. Using similar statistics and methodology, Petersen et al., 2009 found SEM values of between 5% and 24% for MinimaxX devices, and between 3% and 11% with SPI-Pro devices, both at a sampling frequency of 5 Hz. Here, only one device (number 1 produced values above 6% in the 15 m test, while another device (number 2 did so for runs of 30 m. We conclude that the increase in sampling frequency led to increased accuracy of the devices.As regards intra-device reliability, high values were obtained in all cases, and increased when used over 30 m (Figure 1. Some studies have reported differences between
Performance and reliability of TPE-2 device with pulsed high power source
International Nuclear Information System (INIS)
Sato, Y.; Takeda, S.; Kiyama, S.
1987-01-01
The performance and the reliability of TPE-2 device with pulsed high power sources are described. To obtain the stable high beta plasma, the reproducibility and the reliability of the pulsed power sources must be maintained. A new power crowbar system with high efficiency and the switches with low jitter time are adopted to the bank system. A monitor system which always watches the operational states of the switches is developed too, and applied for the fast rising capacitor banks of TPE-2 device. The reliable operation for the bank has been realized, based on the data of switch monitor system
High reliability low jitter 80 kV pulse generator
Directory of Open Access Journals (Sweden)
M. E. Savage
2009-08-01
Full Text Available Switching can be considered to be the essence of pulsed power. Time accurate switch/trigger systems with low inductance are useful in many applications. This article describes a unique switch geometry coupled with a low-inductance capacitive energy store. The system provides a fast-rising high voltage pulse into a low impedance load. It can be challenging to generate high voltage (more than 50 kilovolts into impedances less than 10 Ω, from a low voltage control signal with a fast rise time and high temporal accuracy. The required power amplification is large, and is usually accomplished with multiple stages. The multiple stages can adversely affect the temporal accuracy and the reliability of the system. In the present application, a highly reliable and low jitter trigger generator was required for the Z pulsed-power facility [M. E. Savage, L. F. Bennett, D. E. Bliss, W. T. Clark, R. S. Coats,J. M. Elizondo, K. R. LeChien, H. C. Harjes, J. M. Lehr, J. E. Maenchen, D. H. McDaniel, M. F. Pasik, T. D. Pointon, A. C. Owen, D. B. Seidel, D. L. Smith, B. S. Stoltzfus, K. W. Struve, W. A. Stygar, L. K. Warne, and J. R. Woodworth, 2007 IEEE Pulsed Power Conference, Albuquerque, NM (IEEE, Piscataway, NJ, 2007, p. 979]. The large investment in each Z experiment demands low prefire probability and low jitter simultaneously. The system described here is based on a 100 kV DC-charged high-pressure spark gap, triggered with an ultraviolet laser. The system uses a single optical path for simultaneously triggering two parallel switches, allowing lower inductance and electrode erosion with a simple optical system. Performance of the system includes 6 ns output rise time into 5.6 Ω, 550 ps one-sigma jitter measured from the 5 V trigger to the high voltage output, and misfire probability less than 10^{-4}. The design of the system and some key measurements will be shown in the paper. We will discuss the
Highly reliable TOFD UT Technique
International Nuclear Information System (INIS)
Acharya, G.D.; Trivedi, S.A.R.; Pai, K.B.
2003-01-01
The high performance of the time of flight diffraction technique (TOFD) with regard to the detection capabilities of weld defects such as crack, slag, lack of fusion has led to a rapidly increasing acceptance of the technique as a pre?service inspection tool. Since the early 1990s TOFD has been applied to several projects, where it replaced the commonly used radiographic testing. The use of TOM lead to major time savings during new build and replacement projects. At the same time the TOFD technique was used as base line inspection, which enables monitoring in the future for critical welds, but also provides documented evidence for life?time. The TOFD technique as the ability to detect and simultaneously size flows of nearly any orientation within the weld and heat affected zone. TOM is recognized as a reliable, proven technique for detection and sizing of defects and proven to be a time saver, resulting in shorter shutdown periods and construction project times. Thus even in cases where inspection price of TOFD per welds is higher, in the end it will result in significantly lower overall costs and improve quality. This paper deals with reliability, economy, acceptance criteria and field experience. It also covers comparative study between radiography technique Vs. TOFD. (Author)
Downs, Stephen; Marquez, Jodie; Chiarelli, Pauline
2013-06-01
What is the intra-rater and inter-rater relative reliability of the Berg Balance Scale? What is the absolute reliability of the Berg Balance Scale? Does the absolute reliability of the Berg Balance Scale vary across the scale? Systematic review with meta-analysis of reliability studies. Any clinical population that has undergone assessment with the Berg Balance Scale. Relative intra-rater reliability, relative inter-rater reliability, and absolute reliability. Eleven studies involving 668 participants were included in the review. The relative intrarater reliability of the Berg Balance Scale was high, with a pooled estimate of 0.98 (95% CI 0.97 to 0.99). Relative inter-rater reliability was also high, with a pooled estimate of 0.97 (95% CI 0.96 to 0.98). A ceiling effect of the Berg Balance Scale was evident for some participants. In the analysis of absolute reliability, all of the relevant studies had an average score of 20 or above on the 0 to 56 point Berg Balance Scale. The absolute reliability across this part of the scale, as measured by the minimal detectable change with 95% confidence, varied between 2.8 points and 6.6 points. The Berg Balance Scale has a higher absolute reliability when close to 56 points due to the ceiling effect. We identified no data that estimated the absolute reliability of the Berg Balance Scale among participants with a mean score below 20 out of 56. The Berg Balance Scale has acceptable reliability, although it might not detect modest, clinically important changes in balance in individual subjects. The review was only able to comment on the absolute reliability of the Berg Balance Scale among people with moderately poor to normal balance. Copyright © 2013 Australian Physiotherapy Association. Published by .. All rights reserved.
A High Precision Artificial Neural Networks Model for Short-Term Energy Load Forecasting
Directory of Open Access Journals (Sweden)
Ping-Huan Kuo
2018-01-01
Full Text Available One of the most important research topics in smart grid technology is load forecasting, because accuracy of load forecasting highly influences reliability of the smart grid systems. In the past, load forecasting was obtained by traditional analysis techniques such as time series analysis and linear regression. Since the load forecast focuses on aggregated electricity consumption patterns, researchers have recently integrated deep learning approaches with machine learning techniques. In this study, an accurate deep neural network algorithm for short-term load forecasting (STLF is introduced. The forecasting performance of proposed algorithm is compared with performances of five artificial intelligence algorithms that are commonly used in load forecasting. The Mean Absolute Percentage Error (MAPE and Cumulative Variation of Root Mean Square Error (CV-RMSE are used as accuracy evaluation indexes. The experiment results show that MAPE and CV-RMSE of proposed algorithm are 9.77% and 11.66%, respectively, displaying very high forecasting accuracy.
Seeking high reliability in primary care: Leadership, tools, and organization.
Weaver, Robert R
2015-01-01
Leaders in health care increasingly recognize that improving health care quality and safety requires developing an organizational culture that fosters high reliability and continuous process improvement. For various reasons, a reliability-seeking culture is lacking in most health care settings. Developing a reliability-seeking culture requires leaders' sustained commitment to reliability principles using key mechanisms to embed those principles widely in the organization. The aim of this study was to examine how key mechanisms used by a primary care practice (PCP) might foster a reliability-seeking, system-oriented organizational culture. A case study approach was used to investigate the PCP's reliability culture. The study examined four cultural artifacts used to embed reliability-seeking principles across the organization: leadership statements, decision support tools, and two organizational processes. To decipher their effects on reliability, the study relied on observations of work patterns and the tools' use, interactions during morning huddles and process improvement meetings, interviews with clinical and office staff, and a "collective mindfulness" questionnaire. The five reliability principles framed the data analysis. Leadership statements articulated principles that oriented the PCP toward a reliability-seeking culture of care. Reliability principles became embedded in the everyday discourse and actions through the use of "problem knowledge coupler" decision support tools and daily "huddles." Practitioners and staff were encouraged to report unexpected events or close calls that arose and which often initiated a formal "process change" used to adjust routines and prevent adverse events from recurring. Activities that foster reliable patient care became part of the taken-for-granted routine at the PCP. The analysis illustrates the role leadership, tools, and organizational processes play in developing and embedding a reliable-seeking culture across an
Improving patient safety: patient-focused, high-reliability team training.
McKeon, Leslie M; Cunningham, Patricia D; Oswaks, Jill S Detty
2009-01-01
Healthcare systems are recognizing "human factor" flaws that result in adverse outcomes. Nurses work around system failures, although increasing healthcare complexity makes this harder to do without risk of error. Aviation and military organizations achieve ultrasafe outcomes through high-reliability practice. We describe how reliability principles were used to teach nurses to improve patient safety at the front line of care. Outcomes include safety-oriented, teamwork communication competency; reflections on safety culture and clinical leadership are discussed.
A High Reliability Frequency Stabilized Semiconductor Laser Source, Phase II
National Aeronautics and Space Administration — Ultrastable, narrow linewidth, high reliability MOPA sources are needed for high performance LIDARs in NASA for, wind speed measurement, surface topography and earth...
Soft Pneumatic Actuator Fascicles for High Force and Reliability.
Robertson, Matthew A; Sadeghi, Hamed; Florez, Juan Manuel; Paik, Jamie
2017-03-01
Soft pneumatic actuators (SPAs) are found in mobile robots, assistive wearable devices, and rehabilitative technologies. While soft actuators have been one of the most crucial elements of technology leading the development of the soft robotics field, they fall short of force output and bandwidth requirements for many tasks. In addition, other general problems remain open, including robustness, controllability, and repeatability. The SPA-pack architecture presented here aims to satisfy these standards of reliability crucial to the field of soft robotics, while also improving the basic performance capabilities of SPAs by borrowing advantages leveraged ubiquitously in biology; namely, the structured parallel arrangement of lower power actuators to form the basis of a larger and more powerful actuator module. An SPA-pack module consisting of a number of smaller SPAs will be studied using an analytical model and physical prototype. Experimental measurements show an SPA pack to generate over 112 N linear force, while the model indicates the benefit of parallel actuator grouping over a geometrically equivalent single SPA scale as an increasing function of the number of individual actuators in the group. For a module of four actuators, a 23% increase in force production over a volumetrically equivalent single SPA is predicted and validated, while further gains appear possible up to 50%. These findings affirm the advantage of utilizing a fascicle structure for high-performance soft robotic applications over existing monolithic SPA designs. An example of high-performance soft robotic platform will be presented to demonstrate the capability of SPA-pack modules in a complete and functional system.
Soft Pneumatic Actuator Fascicles for High Force and Reliability
Robertson, Matthew A.; Sadeghi, Hamed; Florez, Juan Manuel
2017-01-01
Abstract Soft pneumatic actuators (SPAs) are found in mobile robots, assistive wearable devices, and rehabilitative technologies. While soft actuators have been one of the most crucial elements of technology leading the development of the soft robotics field, they fall short of force output and bandwidth requirements for many tasks. In addition, other general problems remain open, including robustness, controllability, and repeatability. The SPA-pack architecture presented here aims to satisfy these standards of reliability crucial to the field of soft robotics, while also improving the basic performance capabilities of SPAs by borrowing advantages leveraged ubiquitously in biology; namely, the structured parallel arrangement of lower power actuators to form the basis of a larger and more powerful actuator module. An SPA-pack module consisting of a number of smaller SPAs will be studied using an analytical model and physical prototype. Experimental measurements show an SPA pack to generate over 112 N linear force, while the model indicates the benefit of parallel actuator grouping over a geometrically equivalent single SPA scale as an increasing function of the number of individual actuators in the group. For a module of four actuators, a 23% increase in force production over a volumetrically equivalent single SPA is predicted and validated, while further gains appear possible up to 50%. These findings affirm the advantage of utilizing a fascicle structure for high-performance soft robotic applications over existing monolithic SPA designs. An example of high-performance soft robotic platform will be presented to demonstrate the capability of SPA-pack modules in a complete and functional system. PMID:28289573
Zhong, Tao; Chung, Pak-Kwong; Liu, Jing Dong
2018-02-01
Independent from noise exposure, noise sensitivity plays a pivotal role in people's noise annoyance perception and concomitant health deteriorations. The present study empirically investigated the psychometric properties of the Chinese version of the Weinstein Noise Sensitivity Scale-Short Form (CNSS-SF), the widely used inventory measuring individual differences in noise perception. In total, 373 Chinese participants (age = 21.41 ± 3.36) completed the online, anonymous questionnaire package. Examination of the CNSS-SF's reliability (internal consistency), factorial validity through validation and cross-validation, nomological validity and measurement invariance across gender groups were undertaken. The Cronbach alpha coefficients and composite reliabilities indicated sufficient reliability of the CNSS-SF. Two confirmatory factor analyses (CFA), in two randomly partitioned groups of participants, substantiated the factorial validity of the scale. The nomological validity of the scale was also corroborated by the significant positive association of its score with the trait anxiety score. Measurement invariance of the CNSS-SF was also found across genders via multi-group CFA. Though not without limitations, findings from the present research provide promising evidence for the utility of the scale in measuring noise sensitivity among the Chinese population. The availability of the CNSS-SF can promote research related to environmental noise and health in China, as well as facilitate cross-cultural comparisons. Copyright © 2018 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
On the design of high-rise buildings with a specified level of reliability
Dolganov, Andrey; Kagan, Pavel
2018-03-01
High-rise buildings have a specificity, which significantly distinguishes them from traditional buildings of high-rise and multi-storey buildings. Steel structures in high-rise buildings are advisable to be used in earthquake-proof regions, since steel, due to its plasticity, provides damping of the kinetic energy of seismic impacts. These aspects should be taken into account when choosing a structural scheme of a high-rise building and designing load-bearing structures. Currently, modern regulatory documents do not quantify the reliability of structures. Although the problem of assigning an optimal level of reliability has existed for a long time. The article shows the possibility of designing metal structures of high-rise buildings with specified reliability. Currently, modern regulatory documents do not quantify the reliability of high-rise buildings. Although the problem of assigning an optimal level of reliability has existed for a long time. It is proposed to establish the value of reliability 0.99865 (3σ) for constructions of buildings and structures of a normal level of responsibility in calculations for the first group of limiting states. For increased (construction of high-rise buildings) and reduced levels of responsibility for the provision of load-bearing capacity, it is proposed to assign respectively 0.99997 (4σ) and 0.97725 (2σ). The coefficients of the use of the cross section of a metal beam for different levels of security are given.
High-Capacity Short-Range Optical Communication Links
DEFF Research Database (Denmark)
Tatarczak, Anna
Over the last decade, we have observed a tremendous spread of end-user mobile devices. The user base of a mobile application can grow or shrink by millions per day. This situation creates a pressing need for highly scalable server infrastructure; a need nowadays satisfied through cloud computing...... offered by data centers. As the popularity of cloud computing soars, the demand for high-speed, short-range data center links grows. Vertical cavity surface emitting lasers (VCSEL) and multimode fibers (MMF) prove especially well-suited for such scenarios. VCSELs have high modulation bandwidths......, we achieve 10 Gbps over 400 m and then conrm the approach in an optimized system at 25 Gbps over 300 m. The techniques described in this thesis leverage additional degrees of freedom to better utilize the available resources of short-range links. The proposed schemes enable higher speeds and longer...
High-voltage short-fall pulse generator
International Nuclear Information System (INIS)
Dolbilov, G.V.; Fateev, A.A.; Petrov, V.A.
1986-01-01
Powerful high-voltage pulses with short fall times and relatively low afterpulse amplitude are required for the deflection systems of accelerators. A generator is described that provides, into a 75-ohm load, a voltage pulse of up to 100 kV with a fall time of less than 1 nsec and a relative afterpulse amplitude of less than or equal to 15%. The generator employs a short-circuited ferrite-filled line in which shock waves are formed. A magnetic section is used to increase power. The switch is a TGI1-2500/50 thyratron. The main causes of afterpulses and methods for reducing their amplitude are examined
Reliability-based design optimization via high order response surface method
International Nuclear Information System (INIS)
Li, Hong Shuang
2013-01-01
To reduce the computational effort of reliability-based design optimization (RBDO), the response surface method (RSM) has been widely used to evaluate reliability constraints. We propose an efficient methodology for solving RBDO problems based on an improved high order response surface method (HORSM) that takes advantage of an efficient sampling method, Hermite polynomials and uncertainty contribution concept to construct a high order response surface function with cross terms for reliability analysis. The sampling method generates supporting points from Gauss-Hermite quadrature points, which can be used to approximate response surface function without cross terms, to identify the highest order of each random variable and to determine the significant variables connected with point estimate method. The cross terms between two significant random variables are added to the response surface function to improve the approximation accuracy. Integrating the nested strategy, the improved HORSM is explored in solving RBDO problems. Additionally, a sampling based reliability sensitivity analysis method is employed to reduce the computational effort further when design variables are distributional parameters of input random variables. The proposed methodology is applied on two test problems to validate its accuracy and efficiency. The proposed methodology is more efficient than first order reliability method based RBDO and Monte Carlo simulation based RBDO, and enables the use of RBDO as a practical design tool.
SHORT COMMUNICATION High prevalence of Plasmodium ...
African Journals Online (AJOL)
Dell
Volume 20, Number 1, January 2018. 1. SHORT COMMUNICATION ... This study was designed to establish the prevalence of Plasmodium falciparum malaria among HIV infected populations. ... The prevalence of P. falciparum was high among HIV seropositive individuals in the Lake Victoria Zone, which calls for additional ...
Highly-reliable laser diodes and modules for spaceborne applications
Deichsel, E.
2017-11-01
Laser applications become more and more interesting in contemporary missions such as earth observations or optical communication in space. One of these applications is light detection and ranging (LIDAR), which comprises huge scientific potential in future missions. The Nd:YAG solid-state laser of such a LIDAR system is optically pumped using 808nm emitting pump sources based on semiconductor laser-diodes in quasi-continuous wave (qcw) operation. Therefore reliable and efficient laser diodes with increased output powers are an important requirement for a spaceborne LIDAR-system. In the past, many tests were performed regarding the performance and life-time of such laser-diodes. There were also studies for spaceborne applications, but a test with long operation times at high powers and statistical relevance is pending. Other applications, such as science packages (e.g. Raman-spectroscopy) on planetary rovers require also reliable high-power light sources. Typically fiber-coupled laser diode modules are used for such applications. Besides high reliability and life-time, designs compatible to the harsh environmental conditions must be taken in account. Mechanical loads, such as shock or strong vibration are expected due to take-off or landing procedures. Many temperature cycles with high change rates and differences must be taken in account due to sun-shadow effects in planetary orbits. Cosmic radiation has strong impact on optical components and must also be taken in account. Last, a hermetic sealing must be considered, since vacuum can have disadvantageous effects on optoelectronics components.
Utilizing leadership to achieve high reliability in the delivery of perinatal care
Directory of Open Access Journals (Sweden)
Parrotta C
2012-11-01
Full Text Available Carmen Parrotta,1 William Riley,1 Les Meredith21School of Public Health, University of Minnesota, Minneapolis, MN, 2Premier Insurance Management Services Inc, Charlotte, NC, USAAbstract: Highly reliable care requires standardization of clinical practices and is a prerequisite for patient safety. However, standardization in complex hospital settings is extremely difficult to attain and health care leaders are challenged to create care delivery processes that ensure patient safety. Moreover, once high reliability is achieved in a hospital unit, it must be maintained to avoid process deterioration. This case study examines an intervention to implement care bundles (a collection of evidence-based practices in four hospitals to achieve standardized care in perinatal units. The results show different patterns in the rate and magnitude of change within the hospitals to achieve high reliability. The study is part of a larger nationwide study of 16 hospitals to improve perinatal safety. Based on the findings, we discuss the role of leadership for implementing and sustaining high reliability to ensure freedom from unintended injury.Keywords: care bundles, evidence-based practice, standardized care, process improvement
To the problem of reliability of high-voltage accelerators for industrial purposes
International Nuclear Information System (INIS)
Al'bertinskij, B.I.; Svin'in, M.P.; Tsepakin, S.G.
1979-01-01
Statistical data characterizing the reliability of ELECTRON and AVRORA-2 type accelerators are presented. Used as a reliability index was the mean time to failure of the main accelerator units. The analysis of accelerator failures allowed a number of conclusions to be drawn. The high failure rate level is connected with inadequate training of the servicing personnel and a natural period of equipment adjustment. The mathematical analysis of the failure rate showed that the main responsibility for insufficient high reliability rests with selenium diodes which are employed in the high voltage power supply. Substitution of selenium diodes by silicon ones increases time between failures. It is shown that accumulation and processing of operational statistical data will permit more accurate prediction of the reliability of produced high-voltage accelerators, make it possible to cope with the problems of planning optimal, in time, preventive inspections and repair, and to select optimal safety factors and test procedures n time, preventive inspections and repair, and to select optimal safety factors and test procedures n time, prevent
High-reliability, 4. pi. -scan, leakage-x-ray dosimeter
Energy Technology Data Exchange (ETDEWEB)
Kaneko, T; Iida, H; Yoshida, T; Sugimoto, H [Tokyo Shibaura Electric Co. Ltd., Kawasaki, Kanagawa (Japan). Tamagawa Works
1978-04-01
A world-wide movement is growing for the protection of living bodies against leakage radiations. In Japan, detailed regulations have been established for the enforcement of the law in regard to this problem. The substances of the measurement provided in the regulations are extremely diversified, much affecting the reliability and the economic efficiency of the equipment. Now a new 4..pi..-scan X-ray dosimeter with high reliability has been developed and proved to effect qualitative improvement of measurement as well as elevation of productivity.
Modeling high-Power Accelerators Reliability-SNS LINAC (SNS-ORNL); MAX LINAC (MYRRHA)
International Nuclear Information System (INIS)
Pitigoi, A. E.; Fernandez Ramos, P.
2013-01-01
Improving reliability has recently become a very important objective in the field of particle accelerators. The particle accelerators in operation are constantly undergoing modifications, and improvements are implemented using new technologies, more reliable components or redundant schemes (to obtain more reliability, strength, more power, etc.) A reliability model of SNS (Spallation Neutron Source) LINAC has been developed within MAX project and analysis of the accelerator systems reliability has been performed within the MAX project, using the Risk Spectrum reliability analysis software. The analysis results have been evaluated by comparison with the SNS operational data. Results and conclusions are presented in this paper, oriented to identify design weaknesses and provide recommendations for improving reliability of MYRRHA linear accelerator. The SNS reliability model developed for the MAX preliminary design phase indicates possible avenues for further investigation that could be needed to improve the reliability of the high-power accelerators, in view of the future reliability targets of ADS accelerators.
Validity and Reliability of the Academic Resilience Scale in Turkish High School
Kapikiran, Sahin
2012-01-01
The present study aims to determine the validity and reliability of the academic resilience scale in Turkish high school. The participances of the study includes 378 high school students in total (192 female and 186 male). A set of analyses were conducted in order to determine the validity and reliability of the study. Firstly, both exploratory…
Forward Capacity Markets: Maintaining Grid Reliability in Europe
Chaigneau, Matthieu
2012-01-01
The liberalization process of the electricity industry in many countries leads to new rules and new challenges for the grid management. System reliability is a major concern, mainly because of (a) the high level penetration of renewable energy sources and (b) the growing peak load and environmental regulations In most electricity markets, peak resources operate only during a short period, and at a high operating cost, jeopardizing their return on investment, while low-cost base resources make...
Power system reliability enhancement by using PowerformerTM
Directory of Open Access Journals (Sweden)
Rahmat-Allah Hooshmand
2009-01-01
Full Text Available A high-voltage generator PowerformerTM is a new generation of the AC generators. The most significant advantages of these PowerformerTM are their direct connection to high-voltage grid, higher availability, and more reactive power margin, short term overloading capacity and removing the power transformer from the structure of the power plant. In this paper, the installation effect of these generators on the power system reliability is investigated. The amount of the effects depends on the type and location of the power plant, location of the PowerformerTM, the size of load and network topology. For this purpose, in the 6-bus IEEE RBTS system, the conventional generators are replaced by these new PowerformerTM and then, the reliability indices are evaluated. The simulation results show that the reliability indices such as the expected duration of load curtailment (EDLC and the expected energy not served (EENS are improved. .
Survey of industry methods for producing highly reliable software
International Nuclear Information System (INIS)
Lawrence, J.D.; Persons, W.L.
1994-11-01
The Nuclear Reactor Regulation Office of the US Nuclear Regulatory Commission is charged with assessing the safety of new instrument and control designs for nuclear power plants which may use computer-based reactor protection systems. Lawrence Livermore National Laboratory has evaluated the latest techniques in software reliability for measurement, estimation, error detection, and prediction that can be used during the software life cycle as a means of risk assessment for reactor protection systems. One aspect of this task has been a survey of the software industry to collect information to help identify the design factors used to improve the reliability and safety of software. The intent was to discover what practices really work in industry and what design factors are used by industry to achieve highly reliable software. The results of the survey are documented in this report. Three companies participated in the survey: Computer Sciences Corporation, International Business Machines (Federal Systems Company), and TRW. Discussions were also held with NASA Software Engineering Lab/University of Maryland/CSC, and the AIAA Software Reliability Project
Engineering high reliability, low-jitter Marx generators
International Nuclear Information System (INIS)
Schneider, L.X.; Lockwood, G.J.
1985-01-01
Multimodule pulsed power accelerators typically require high module reliability and nanosecond regime simultaneity between modules. Energy storage using bipolar Marx generators can meet these requirements. Experience gained from computer simulations and the development of the DEMON II Marx generator has led to a fundamental understanding of the operation of these multistage devices. As a result of this research, significant improvements in erection time jitter and reliability have been realized in multistage, bipolar Marx generators. Erection time jitter has been measured as low as 2.5 nanoseconds for the 3.2MV, 16-stage PBFA I Marx and 3.5 nanoseconds for the 6.0MV, 30-stage PBFA II (DEMON II) Marx, while maintaining exceptionally low prefire rates. Performance data are presented from the DEMON II Marx research program, as well as discussions on the use of computer simulations in designing low-jitter Marx generators
Lewis, Christopher Alan; Cruise, Sharon Mary; McGuckin, Conor
2005-04-01
This study evaluated the test-retest reliability of the Francis Scale of Attitude toward Christianity short-form. 39 Northern Irish undergraduate students completed the measure on two occasions separated by one week. Stability across the two administrations was high, r = .92, and there was no significant change between Time 1(M = 25.2, SD = 5.4) and Time 2 (M = 25.7, SD = 6.2). These data support the short-term test-retest reliability of the Francis Scale of Attitude toward Christianity short-form.
Instrument reliability for high-level nuclear-waste-repository applications
International Nuclear Information System (INIS)
Rogue, F.; Binnall, E.P.; Armantrout, G.A.
1983-01-01
Reliable instrumentation will be needed to evaluate the characteristics of proposed high-level nuclear-wasted-repository sites and to monitor the performance of selected sites during the operational period and into repository closure. A study has been done to assess the reliability of instruments used in Department of Energy (DOE) waste repository related experiments and in other similar geological applications. The study included experiences with geotechnical, hydrological, geochemical, environmental, and radiological instrumentation and associated data acquisition equipment. Though this paper includes some findings on the reliability of instruments in each of these categories, the emphasis is on experiences with geotechnical instrumentation in hostile repository-type environments. We review the failure modes, rates, and mechanisms, along with manufacturers modifications and design changes to enhance and improve instrument performance; and include recommendations on areas where further improvements are needed
Accurate Short-Term Power Forecasting of Wind Turbines: The Case of Jeju Island’s Wind Farm
BeomJun Park; Jin Hur
2017-01-01
Short-term wind power forecasting is a technique which tells system operators how much wind power can be expected at a specific time. Due to the increasing penetration of wind generating resources into the power grids, short-term wind power forecasting is becoming an important issue for grid integration analysis. The high reliability of wind power forecasting can contribute to the successful integration of wind generating resources into the power grids. To guarantee the reliability of forecas...
Introduction to nanotechnology: a short course for high school students
Markin, Alexey V.
2016-04-01
This report devoted to presenting results of development and implementation of a short course (4 hours) entitled "Introduction to Nanotechnology" that was specially designed for familiarizing high school students with nanomaterials and nanotechnology. The course contains introduction to nanotechnology, essential definitions, short overview of history, descriptions for various examples of nanomaterials and their classifications, performing demonstration experiments. All these parts of the course are briefly analyzed from pedagogical effectiveness point of view. Finally, results of course testing, problems and perspectives of nano-oriented education at high school are also discussed shortly.
OTDM Networking for Short Range High-Capacity Highly Dynamic Networks
DEFF Research Database (Denmark)
Medhin, Ashenafi Kiros
This PhD thesis aims at investigating the possibility of designing energy-efficient high-capacity (up to Tbit/s) optical network scenarios, leveraging on the effect of collective switching of many bits simultaneously, as is inherent in high bit rate serial optical data signals. The focus...... is on short range highly dynamic networks, catering to data center needs. The investigation concerns optical network scenarios, and experimental implementations of high bit rate serial data packet generation and reception, scalable optical packet labeling, simple optical label extraction and stable ultra...
The role of high cycle fatigue (HCF) onset in Francis runner reliability
International Nuclear Information System (INIS)
Gagnon, M; Tahan, S A; Bocher, P; Thibault, D
2012-01-01
High Cycle Fatigue (HCF) plays an important role in Francis runner reliability. This paper presents a model in which reliability is defined as the probability of not exceeding a threshold above which HCF contributes to crack propagation. In the context of combined Low Cycle Fatigue (LCF) and HCF loading, the Kitagawa diagram is used as the limit state threshold for reliability. The reliability problem is solved using First-Order Reliability Methods (FORM). A study case is proposed using in situ measured strains and operational data. All the parameters of the reliability problem are based either on observed data or on typical design specifications. From the results obtained, we observed that the uncertainty around the defect size and the HCF stress range play an important role in reliability. At the same time, we observed that expected values for the LCF stress range and the number of LCF cycles have a significant influence on life assessment, but the uncertainty around these values could be neglected in the reliability assessment.
Efficiency criteria for high reliability measured system structures
International Nuclear Information System (INIS)
Sal'nikov, N.L.
2012-01-01
The procedures of structural redundancy are usually used to develop high reliability measured systems. To estimate efficiency of such structures the criteria to compare different systems has been developed. So it is possible to develop more exact system by inspection of redundant system data unit stochastic characteristics in accordance with the developed criteria [ru
Designing reliability into high-effectiveness industrial gas turbine regenerators
International Nuclear Information System (INIS)
Valentino, S.J.
1979-01-01
The paper addresses the measures necessary to achieve a reliable regenerator design that can withstand higher temperatures (1000-1200 F) and many start and stop cycles - conditions encountered in high-efficiency operation in pipeline applications. The discussion is limited to three major areas: (1) structural analysis of the heat exchanger core - the part of the regenerator that must withstand the higher temperatures and cyclic duty (2) materials data and material selection and (3) a comprehensive test program to demonstrate the reliability of the regenerator. This program includes life-cycle tests, pressure containment in fin panels, core-to-core joint structural test, bellows pressure containment test, sliding pad test, core gas-side passage flow distribution test, and production test. Today's regenerators must have high cyclic life capability, stainless steel construction, and long fault-free service life of 120,000 hr
Short-circuit experiments on a high Tc-superconducting cable conductor
DEFF Research Database (Denmark)
Tønnesen, Ole; Jensen, E.H.; Traholt, C.
2002-01-01
A high temperature superconductor (HTS) cable conductor (CC) with a critical current of 2.1 kA was tested over a range of short-circuit currents up to 20 kA. The duration of the short-circuit currents is 1 s. Between each short-circuit test the critical current of the HTS CC was measured in order...
THE RELIABILITY OF DETERMINING THE SHORT CIRCUIT ZONE OF THE LINES OF 6–35 kV
Directory of Open Access Journals (Sweden)
F. А. Romaniuk
2018-01-01
Full Text Available A method of increasing the reliability of determining the zone of short-circuit at the current step protection of the lines of 6–35 kV with unilateral power, aimed at improvement of their technical perfection, is presented in the paper. Having taken the relative simpleness of the current protection into account the authors consider the unilateral remote method of accounting the parameters of the emergency mode and the type of fault to be the most suitable for the implementation of the algorithm of its functioning as compared with the existing methods of fault location. The major factors affecting the accuracy of determining the short circuit zone based on the remote method are noted. With the use of the method of computational experiment the influence of the load currents and contact resistances of various levels on the magnitude and character of changes of errors of determination of the calculated distance of the point of fault from the protection installation location taking into account the errors of measuring transformers. It is demonstrated that in many cases of arc short circuit in a loaded line in order to define the zone of short-circuit with fair accuracy correction of the estimated distance to the fault as calculated by the parameters of the damaged loop (loops is required. According to the results of numerical experiments corrective expressions on the basis of two relative asymmetry currents determined by the current values of the differences of the phase currents of the line for detecting a type of a short circuit have been obtained. The assessment of the efficiency of the proposed method has been performed. It is shown that the application of the proposed correction method makes it possible to increase the accuracy of fault zone detection. The dynamic properties of the proposed method applied to different modes of the line functioning have been studied. It is determined that in the worst case the definition of the fault zone for a
Systems reliability in high risk situations
International Nuclear Information System (INIS)
Hunns, D.M.
1974-12-01
A summary is given of five papers and the discussion of a seminar promoted by the newly-formed National Centre of Systems Reliability. The topics covered include hazard analysis, reliability assessment, and risk assessment in both nuclear and non-nuclear industries. (U.K.)
A short form of the neonatal intensive care unit family needs inventory
Directory of Open Access Journals (Sweden)
Elisabete Alves
2016-01-01
Conclusions: The Short Form of the NICU Family Needs Inventory is a brief, simple, and valid instrument with a high degree of reliability. Further studies are needed to explore associations with practices of family‐centered care.
Short-time, high-dosage penicillin infusion therapy of syphilis
DEFF Research Database (Denmark)
Lomholt, Hans; Poulsen, Asmus; Brandrup, Flemming
2003-01-01
The optimal dosage and duration of penicillin treatment for the various stages of syphilis are not known. We present data on 20 patients with syphilis (primary, secondary or latent) treated with high-dose, short-time penicillin infusion therapy. Patients were given 10 MIU of penicillin G intraven......The optimal dosage and duration of penicillin treatment for the various stages of syphilis are not known. We present data on 20 patients with syphilis (primary, secondary or latent) treated with high-dose, short-time penicillin infusion therapy. Patients were given 10 MIU of penicillin G...
Impact of High-Reliability Education on Adverse Event Reporting by Registered Nurses.
McFarland, Diane M; Doucette, Jeffrey N
Adverse event reporting is one strategy to identify risks and improve patient safety, but, historically, adverse events are underreported by registered nurses (RNs) because of fear of retribution and blame. A program was provided on high reliability to examine whether education would impact RNs' willingness to report adverse events. Although the findings were not statistically significant, they demonstrated a positive impact on adverse event reporting and support the need to create a culture of high reliability.
Gearbox Reliability Collaborative High-Speed Shaft Calibration
Energy Technology Data Exchange (ETDEWEB)
Keller, J.; McNiff, B.
2014-09-01
Instrumentation has been added to the high-speed shaft, pinion, and tapered roller bearing pair of the Gearbox Reliability Collaborative gearbox to measure loads and temperatures. The new shaft bending moment and torque instrumentation was calibrated and the purpose of this document is to describe this calibration process and results, such that the raw shaft bending and torque signals can be converted to the proper engineering units and coordinate system reference for comparison to design loads and simulation model predictions.
Learning Organizations in High Reliability Industries
International Nuclear Information System (INIS)
Schwalbe, D.; Wächter, C.
2016-01-01
Full text: Humans make mistakes. Sometimes we learn from them. In a high reliability organization we have to learn before an error leads to an incident (or even accident). Therefore the “human factor” is most important as most of the time the human is the last line of defense. The “human factor” is more than communication or leadership skills. At the end, it is the personal attitude. This attitude has to be safety minded. And this attitude has to be self-reflected continuously. Moreover, feedback from others is urgently needed to improve one’s personal skills daily and learn from our own experience as well as from others. (author
Cruz-Orduña, Isabel; Agüera-Ortiz, Luis F; Montorio-Cerrato, Ignacio; León-Salas, Beatriz; Valle de Juan, M Cristina; Martínez-Martín, Pablo
2015-01-01
People with progressive dementia evolve into a state where traditional neuropsychological tests are not effective. Severe Impairment Battery (SIB) and short form (SIB-s) were developed for evaluating the cognitive status in patients with severe dementia. To evaluate the psychometric attributes of the SIB-s in patients with severe dementia. 127 institutionalized patients (female: 86.6%; mean age: 82.6 ± 7.5 years-old) with dementia were assessed with the SIB-s, the Global Deterioration Scale (GDS), Mini-Mental State Examination (MMSE), Severe Mini-Mental State Examination (sMMSE), Barthel Index and FAST. SIB-s acceptability, reliability, validity and precision were analyzed. The mean total score for scale was 19.1 ± 15.34 (range: 0-48). Floor effect was 18.1%, only marginally higher than the desirable 15%. Factor analysis identified a single factor explaining 68% of the total variance of the scale. Cronbach's alpha coefficient was 0.96 and the item-total corrected correlation ranged from 0.27 to 0.83. The item homogeneity value was 0.43. Test-retest and inter-rater reliability for the total score was satisfactory (ICC: 0.96 and 0.95, respectively). The SIB-s showed moderate correlation with functional dependency scales (Barthel Index: 0.48, FAST: -0.74). Standard error of measurement was 3.07 for the total score. The SIB-s is a reliable and valid instrument for evaluating patients with severe dementia in the Spanish population of relatively brief instruments.
Improving the Short-Circuit Reliability in IGBTs
DEFF Research Database (Denmark)
Reigosa, Paula Diaz; Iannuzzo, Francesco; Rahimo, Munaf
2018-01-01
takes place during the IGBT short-circuit, whose time-varying element is the Miller capacitance, which is involved in the amplification mechanism. This hypothesis has been validated through simulations and its mitigation is possible by increasing the electric field at the emitter of the IGBT......In this paper, the oscillation mechanism limiting the ruggedness of IGBTs is investigated through both circuit and device analysis. The work presented here is based on a time-domain approach for two different IGBT cell structures (i.e., trench-gate and planar), illustrating the 2-D effects during...
Hawaii Electric System Reliability
Energy Technology Data Exchange (ETDEWEB)
Loose, Verne William [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Silva Monroy, Cesar Augusto [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
2012-08-01
This report addresses Hawaii electric system reliability issues; greater emphasis is placed on short-term reliability but resource adequacy is reviewed in reference to electric consumers’ views of reliability “worth” and the reserve capacity required to deliver that value. The report begins with a description of the Hawaii electric system to the extent permitted by publicly available data. Electrical engineering literature in the area of electric reliability is researched and briefly reviewed. North American Electric Reliability Corporation standards and measures for generation and transmission are reviewed and identified as to their appropriateness for various portions of the electric grid and for application in Hawaii. Analysis of frequency data supplied by the State of Hawaii Public Utilities Commission is presented together with comparison and contrast of performance of each of the systems for two years, 2010 and 2011. Literature tracing the development of reliability economics is reviewed and referenced. A method is explained for integrating system cost with outage cost to determine the optimal resource adequacy given customers’ views of the value contributed by reliable electric supply. The report concludes with findings and recommendations for reliability in the State of Hawaii.
An FEC Adaptive Multicast MAC Protocol for Providing Reliability in WLANs
Basalamah, Anas; Sato, Takuro
For wireless multicast applications like multimedia conferencing, voice over IP and video/audio streaming, a reliable transmission of packets within short delivery delay is needed. Moreover, reliability is crucial to the performance of error intolerant applications like file transfer, distributed computing, chat and whiteboard sharing. Forward Error Correction (FEC) is frequently used in wireless multicast to enhance Packet Error Rate (PER) performance, but cannot assure full reliability unless coupled with Automatic Repeat Request forming what is knows as Hybrid-ARQ. While reliable FEC can be deployed at different levels of the protocol stack, it cannot be deployed on the MAC layer of the unreliable IEEE802.11 WLAN due to its inability to exchange ACKs with multiple recipients. In this paper, we propose a Multicast MAC protocol that enhances WLAN reliability by using Adaptive FEC and study it's performance through mathematical analysis and simulation. Our results show that our protocol can deliver high reliability and throughput performance.
Thomas, David E.
2013-01-01
This executive position paper proposes recommendations for designing reform models between public and private sectors dedicated to improving school reform work in low performing urban high schools. It reviews scholarly research about for-profit educational management organizations, high reliability organizations, American high school reform, and…
The reliability of commonly used electrophysiology measures.
Brown, K E; Lohse, K R; Mayer, I M S; Strigaro, G; Desikan, M; Casula, E P; Meunier, S; Popa, T; Lamy, J-C; Odish, O; Leavitt, B R; Durr, A; Roos, R A C; Tabrizi, S J; Rothwell, J C; Boyd, L A; Orth, M
Electrophysiological measures can help understand brain function both in healthy individuals and in the context of a disease. Given the amount of information that can be extracted from these measures and their frequent use, it is essential to know more about their inherent reliability. To understand the reliability of electrophysiology measures in healthy individuals. We hypothesized that measures of threshold and latency would be the most reliable and least susceptible to methodological differences between study sites. Somatosensory evoked potentials from 112 control participants; long-latency reflexes, transcranial magnetic stimulation with resting and active motor thresholds, motor evoked potential latencies, input/output curves, and short-latency sensory afferent inhibition and facilitation from 84 controls were collected at 3 visits over 24 months at 4 Track-On HD study sites. Reliability was assessed using intra-class correlation coefficients for absolute agreement, and the effects of reliability on statistical power are demonstrated for different sample sizes and study designs. Measures quantifying latencies, thresholds, and evoked responses at high stimulator intensities had the highest reliability, and required the smallest sample sizes to adequately power a study. Very few between-site differences were detected. Reliability and susceptibility to between-site differences should be evaluated for electrophysiological measures before including them in study designs. Levels of reliability vary substantially across electrophysiological measures, though there are few between-site differences. To address this, reliability should be used in conjunction with theoretical calculations to inform sample size and ensure studies are adequately powered to detect true change in measures of interest. Copyright © 2017 Elsevier Inc. All rights reserved.
Sub-nanosecond jitter, repetitive impulse generators for high reliability applications
International Nuclear Information System (INIS)
Krausse, G.J.; Sarjeant, W.J.
1981-01-01
Low jitter, high reliability impulse generator development has recently become of ever increasing importance for developing nuclear physics and weapons applications. The research and development of very low jitter (< 30 ps), multikilovolt generators for high reliability, minimum maintenance trigger applications utilizing a new class of high-pressure tetrode thyratrons now commercially available are described. The overall system design philosophy is described followed by a detailed analysis of the subsystem component elements. A multi-variable experimental analysis of this new tetrode thyratron was undertaken, in a low-inductance configuration, as a function of externally available parameters. For specific thyratron trigger conditions, rise times of 18 ns into 6.0-Ω loads were achieved at jitters as low as 24 ps. Using this database, an integrated trigger generator system with solid-state front-end is described in some detail. The generator was developed to serve as the Master Trigger Generator for a large neutrino detector installation at the Los Alamos Meson Physics Facility
Reliable on-line storage in the ALICE High-Level Trigger
Energy Technology Data Exchange (ETDEWEB)
Kalcher, Sebastian; Lindenstruth, Volker [Kirchhoff Institute of Physics, University of Heidelberg (Germany)
2009-07-01
The on-line disk capacity within large computing clusters such as used in the ALICE High-Level Trigger (HLT) is often not used due to the inherent unreliability of the involved disks. With currently available hard drive capacities the total on-line capacity can be significant when compared to the storage requirements of present high energy physics experiments. In this talk we report on ClusterRAID, a reliable, distributed mass storage system, which allows to harness the (often unused) disk capacities of large cluster installations. The key paradigm of this system is to transform the local hard drive into a reliable device. It provides adjustable fault-tolerance by utilizing sophisticated error-correcting codes. To reduce the costs of coding and decoding operations the use of modern graphics processing units as co-processor has been investigated. Also, the utilization of low overhead, high performance communication networks has been examined. A prototype set up of the system exists within the HLT with 90 TB gross capacity.
High-repetition-rate short-pulse gas discharge.
Tulip, J; Seguin, H; Mace, P N
1979-09-01
A high-average-power short-pulse gas discharge is described. This consists of a volume-preionized transverse discharge of the type used in gas lasers driven by a Blumlein energy storage circuit. The Blumlein circuit is fabricated from coaxial cable, is pulse-charged from a high-repetition-rate Marx-bank generator, and is switched by a high-repetition-rate segmented rail gap. The operation of this discharge under conditions typical of rare-gas halide lasers is described. A maximum of 900 pps was obtained, giving a power flow into the discharge of 30 kW.
High level issues in reliability quantification of safety-critical software
International Nuclear Information System (INIS)
Kim, Man Cheol
2012-01-01
For the purpose of developing a consensus method for the reliability assessment of safety-critical digital instrumentation and control systems in nuclear power plants, several high level issues in reliability assessment of the safety-critical software based on Bayesian belief network modeling and statistical testing are discussed. Related to the Bayesian belief network modeling, the relation between the assessment approach and the sources of evidence, the relation between qualitative evidence and quantitative evidence, how to consider qualitative evidence, and the cause-consequence relation are discussed. Related to the statistical testing, the need of the consideration of context-specific software failure probabilities and the inability to perform a huge number of tests in the real world are discussed. The discussions in this paper are expected to provide a common basis for future discussions on the reliability assessment of safety-critical software. (author)
Transferring Aviation Practices into Clinical Medicine for the Promotion of High Reliability.
Powell-Dunford, Nicole; McPherson, Mark K; Pina, Joseph S; Gaydos, Steven J
2017-05-01
Aviation is a classic example of a high reliability organization (HRO)-an organization in which catastrophic events are expected to occur without control measures. As health care systems transition toward high reliability, aviation practices are increasingly transferred for clinical implementation. A PubMed search using the terms aviation, crew resource management, and patient safety was undertaken. Manuscripts authored by physician pilots and accident investigation regulations were analyzed. Subject matter experts involved in adoption of aviation practices into the medical field were interviewed. A PubMed search yielded 621 results with 22 relevant for inclusion. Improved clinical outcomes were noted in five research trials in which aviation practices were adopted, particularly with regard to checklist usage and crew resource-management training. Effectiveness of interventions was influenced by intensity of application, leadership involvement, and provision of staff training. The usefulness of incorporating mishap investigation techniques has not been established. Whereas aviation accident investigation is highly standardized, the investigation of medical error is characterized by variation. The adoption of aviation practices into clinical medicine facilitates an evolution toward high reliability. Evidence for the efficacy of the checklist and crew resource-management training is robust. Transference of aviation accident investigation practices is preliminary. A standardized, independent investigation process could facilitate the development of a safety culture commensurate with that achieved in the aviation industry.Powell-Dunford N, McPherson MK, Pina JS, Gaydos SJ. Transferring aviation practices into clinical medicine for the promotion of high reliability. Aerosp Med Hum Perform. 2017; 88(5):487-491.
Reliability of force-velocity relationships during deadlift high pull.
Lu, Wei; Boyas, Sébastien; Jubeau, Marc; Rahmani, Abderrahmane
2017-11-13
This study aimed to evaluate the within- and between-session reliability of force, velocity and power performances and to assess the force-velocity relationship during the deadlift high pull (DHP). Nine participants performed two identical sessions of DHP with loads ranging from 30 to 70% of body mass. The force was measured by a force plate under the participants' feet. The velocity of the 'body + lifted mass' system was calculated by integrating the acceleration and the power was calculated as the product of force and velocity. The force-velocity relationships were obtained from linear regression of both mean and peak values of force and velocity. The within- and between-session reliability was evaluated by using coefficients of variation (CV) and intraclass correlation coefficients (ICC). Results showed that DHP force-velocity relationships were significantly linear (R² > 0.90, p 0.94), mean and peak velocities showed a good agreement (CV reliable and can therefore be utilised as a tool to characterise individuals' muscular profiles.
Direct unavailability computation of a maintained highly reliable system
Czech Academy of Sciences Publication Activity Database
Briš, R.; Byczanski, Petr
2010-01-01
Roč. 224, č. 3 (2010), s. 159-170 ISSN 1748-0078 Grant - others:GA Mšk(CZ) MSM6198910007 Institutional research plan: CEZ:AV0Z30860518 Keywords : high reliability * availability * directed acyclic graph Subject RIV: BA - General Mathematics http:// journals .pepublishing.com/content/rtp3178l17923m46/
Implementing eco friendly highly reliable upload feature using multi 3G service
Tanutama, Lukas; Wijaya, Rico
2017-12-01
The current trend of eco friendly Internet access is preferred. In this research the understanding of eco friendly is minimum power consumption. The devices that are selected have operationally low power consumption and normally have no power consumption as they are hibernating during idle state. To have the reliability a router of a router that has internal load balancing feature will provide the improvement of previous research on multi 3G services for broadband lines. Previous studies emphasized on accessing and downloading information files from Public Cloud residing Web Servers. The demand is not only for speed but high reliability of access as well. High reliability will mean mitigating both direct and indirect high cost due to repeated attempts of uploading and downloading the large files. Nomadic and mobile computer users need viable solution. Following solution for downloading information has been proposed and tested. The solution is promising. The result is now extended to providing reliable access line by means of redundancy and automatic reconfiguration for uploading and downloading large information files to a Web Server in the Cloud. The technique is taking advantage of internal load balancing feature to provision a redundant line acting as a backup line. A router that has the ability to provide load balancing to several WAN lines is chosen. The WAN lines are constructed using multiple 3G lines. The router supports the accessing Internet with more than one 3G access line which increases the reliability and availability of the Internet access as the second line immediately takes over if the first line is disturbed.
Ayvat, Ender; Kilinç, Muhammed; Kirdi, Nuray
2017-06-12
This study aimed to describe the cultural adaptation of the Turkish Physical Activity Scale for the Elderly (PASE) and to examine the reliability and validity of the scale in older Turkish adults. Eighty elderly people were recruited for the study. The assessments included the PASE, the International Physical Activity Questionnaire (IPAQ), the Short Physical Performance Battery and Short Form-36 Quality of Life Questionnaire (SF-36), and the Mini Mental State Test. Outcome measures were conducted twice within a week (test-retest) for reliability. Cronbach's α coefficient was 0.714 for the initial evaluation. The intraclass correlation coefficient for the test-retest reliability was 0.995 with a 95% confidence interval of 0.993-0.997. A high level of positive correlation (0.742, P reliable and valid scale for the fields of research and practice.
MacDonald, James; Duerson, Drew
2015-07-01
Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing
Lee, Hayan; Schatz, Michael C
2012-08-15
Genome resequencing and short read mapping are two of the primary tools of genomics and are used for many important applications. The current state-of-the-art in mapping uses the quality values and mapping quality scores to evaluate the reliability of the mapping. These attributes, however, are assigned to individual reads and do not directly measure the problematic repeats across the genome. Here, we present the Genome Mappability Score (GMS) as a novel measure of the complexity of resequencing a genome. The GMS is a weighted probability that any read could be unambiguously mapped to a given position and thus measures the overall composition of the genome itself. We have developed the Genome Mappability Analyzer to compute the GMS of every position in a genome. It leverages the parallelism of cloud computing to analyze large genomes, and enabled us to identify the 5-14% of the human, mouse, fly and yeast genomes that are difficult to analyze with short reads. We examined the accuracy of the widely used BWA/SAMtools polymorphism discovery pipeline in the context of the GMS, and found discovery errors are dominated by false negatives, especially in regions with poor GMS. These errors are fundamental to the mapping process and cannot be overcome by increasing coverage. As such, the GMS should be considered in every resequencing project to pinpoint the 'dark matter' of the genome, including of known clinically relevant variations in these regions. The source code and profiles of several model organisms are available at http://gma-bio.sourceforge.net
Lifetime Reliability Assessment of Concrete Slab Bridges
DEFF Research Database (Denmark)
Thoft-Christensen, Palle
A procedure for lifetime assesment of the reliability of short concrete slab bridges is presented in the paper. Corrosion of the reinforcement is the deterioration mechanism used for estimating the reliability profiles for such bridges. The importance of using sensitivity measures is stressed....... Finally the produce is illustrated on 6 existing UK bridges....
Hawaii electric system reliability.
Energy Technology Data Exchange (ETDEWEB)
Silva Monroy, Cesar Augusto; Loose, Verne William
2012-09-01
This report addresses Hawaii electric system reliability issues; greater emphasis is placed on short-term reliability but resource adequacy is reviewed in reference to electric consumers' views of reliability %E2%80%9Cworth%E2%80%9D and the reserve capacity required to deliver that value. The report begins with a description of the Hawaii electric system to the extent permitted by publicly available data. Electrical engineering literature in the area of electric reliability is researched and briefly reviewed. North American Electric Reliability Corporation standards and measures for generation and transmission are reviewed and identified as to their appropriateness for various portions of the electric grid and for application in Hawaii. Analysis of frequency data supplied by the State of Hawaii Public Utilities Commission is presented together with comparison and contrast of performance of each of the systems for two years, 2010 and 2011. Literature tracing the development of reliability economics is reviewed and referenced. A method is explained for integrating system cost with outage cost to determine the optimal resource adequacy given customers' views of the value contributed by reliable electric supply. The report concludes with findings and recommendations for reliability in the State of Hawaii.
Leadership in organizations with high security and reliability requirements
International Nuclear Information System (INIS)
Gonzalez, F.
2013-01-01
Developing leadership skills in organizations is the key to ensure the sustainability of excellent results in industries with high requirements safety and reliability. In order to have a model of leadership development specific to this type of organizations, Tecnatom in 2011, we initiated a project internal, to find and adapt a competency model to these requirements.
Meta-Heuristics in Short Scale Construction: Ant Colony Optimization and Genetic Algorithm.
Schroeders, Ulrich; Wilhelm, Oliver; Olaru, Gabriel
2016-01-01
The advent of large-scale assessment, but also the more frequent use of longitudinal and multivariate approaches to measurement in psychological, educational, and sociological research, caused an increased demand for psychometrically sound short scales. Shortening scales economizes on valuable administration time, but might result in inadequate measures because reducing an item set could: a) change the internal structure of the measure, b) result in poorer reliability and measurement precision, c) deliver measures that cannot effectively discriminate between persons on the intended ability spectrum, and d) reduce test-criterion relations. Different approaches to abbreviate measures fare differently with respect to the above-mentioned problems. Therefore, we compare the quality and efficiency of three item selection strategies to derive short scales from an existing long version: a Stepwise COnfirmatory Factor Analytical approach (SCOFA) that maximizes factor loadings and two metaheuristics, specifically an Ant Colony Optimization (ACO) with a tailored user-defined optimization function and a Genetic Algorithm (GA) with an unspecific cost-reduction function. SCOFA compiled short versions were highly reliable, but had poor validity. In contrast, both metaheuristics outperformed SCOFA and produced efficient and psychometrically sound short versions (unidimensional, reliable, sensitive, and valid). We discuss under which circumstances ACO and GA produce equivalent results and provide recommendations for conditions in which it is advisable to use a metaheuristic with an unspecific out-of-the-box optimization function.
DEFF Research Database (Denmark)
Pouwer, F; Van Der Ploeg, Henk M; Adér, Herman J
1999-01-01
OBJECTIVE: The objective of this study was to investigate the validity and reliability of the short-form 12-Item Well-Being Questionnaire (W-BQ12). The 12 items were used to construct the three 4-item subscales Negative Well-Being (NWB), Energy (ENE), and Positive Well-Being (PWB), and the 12-item...... and 701 as having type 2 diabetes. Cronbach's alpha proved to be high and stable across sex and type of diabetes for all W-BQ12 scales. Test-retest reliability ranged from 0.66 (PWB) to 0.83 (GWB), with a mean interval of 66 +/- 14 days. Convergent validity of the W-BQ12 scales was supported by high....../psychiatrist. CONCLUSIONS: The W-BQ12 appeared to be a reliable and valid measure of psychological well-being. This short instrument is easy to administer and may be considered a useful tool for both clinicians and researchers to assess the psychological well-being of patients with diabetes....
Kim, Minjin; Kim, Gi-Hwan; Oh, Kyoung Suk; Jo, Yimhyun; Yoon, Hyun; Kim, Ka-Hyun; Lee, Heon; Kim, Jin Young; Kim, Dong Suk
2017-06-27
Organic-inorganic hybrid metal halide perovskite solar cells (PSCs) are attracting tremendous research interest due to their high solar-to-electric power conversion efficiency with a high possibility of cost-effective fabrication and certified power conversion efficiency now exceeding 22%. Although many effective methods for their application have been developed over the past decade, their practical transition to large-size devices has been restricted by difficulties in achieving high performance. Here we report on the development of a simple and cost-effective production method with high-temperature and short-time annealing processing to obtain uniform, smooth, and large-size grain domains of perovskite films over large areas. With high-temperature short-time annealing at 400 °C for 4 s, the perovskite film with an average domain size of 1 μm was obtained, which resulted in fast solvent evaporation. Solar cells fabricated using this processing technique had a maximum power conversion efficiency exceeding 20% over a 0.1 cm 2 active area and 18% over a 1 cm 2 active area. We believe our approach will enable the realization of highly efficient large-area PCSs for practical development with a very simple and short-time procedure. This simple method should lead the field toward the fabrication of uniform large-scale perovskite films, which are necessary for the production of high-efficiency solar cells that may also be applicable to several other material systems for more widespread practical deployment.
High-intensity exercise and recovery during short-term ...
African Journals Online (AJOL)
Objective. To determine the effect of short-term creatine supplementation plus a protein-carbohydrate formula on high-intensity exercise performance and recovery. Design. A repeated-measures, experimental study, employing a randomised, double-blind, placebo-controlled, group comparison design was used.
Anomalous high photoconductivity in short channel indium-zinc-oxide photo-transistors
International Nuclear Information System (INIS)
Choi, Hyun-Sik; Jeon, Sanghun
2015-01-01
Upon light exposure, an indium-zinc-oxide (IZO) thin-film transistor (TFT) presents higher photoconductivity by several orders of magnitude at the negative gate bias region. Among various device geometrical factors, scaling down the channel length of the photo-transistor results in an anomalous increase in photoconductivity. To probe the origin of this high photoconductivity in short-channel device, we measured transient current, current–voltage, and capacitance–voltage characteristics of IZO–TFTs with various channel lengths and widths before and after illumination. Under the illumination, the equilibrium potential region which lies far from front interface exists only in short-channel devices, forming the un-depleted conducting back channel. This region plays an important role in carrier transport under the illumination, leading to high photoconductivity in short-channel devices. Photon exposure coupled with gate-modulated band bending for short-channel devices leads to the accumulation of V o ++ at the front channel and screening negative gate bias, thereby generating high current flow in the un-depleted back-channel region
Surviving the Lead Reliability Engineer Role in High Unit Value Projects
Perez, Reinaldo J.
2011-01-01
A project with a very high unit value within a company is defined as a project where a) the project constitutes one of a kind (or two-of-a-kind) national asset type of project, b) very large cost, and c) a mission failure would be a very public event that will hurt the company's image. The Lead Reliability engineer in a high visibility project is by default involved in all phases of the project, from conceptual design to manufacture and testing. This paper explores a series of lessons learned, over a period of ten years of practical industrial experience by a Lead Reliability Engineer. We expand on the concepts outlined by these lessons learned via examples. The lessons learned are applicable to all industries.
Reliability engineering for nuclear and other high technology systems
International Nuclear Information System (INIS)
Lakner, A.A.; Anderson, R.T.
1985-01-01
This book is written for the reliability instructor, program manager, system engineer, design engineer, reliability engineer, nuclear regulator, probability risk assessment (PRA) analyst, general manager and others who are involved in system hardware acquisition, design and operation and are concerned with plant safety and operational cost-effectiveness. It provides criteria, guidelines and comprehensive engineering data affecting reliability; it covers the key aspects of system reliability as it relates to conceptual planning, cost tradeoff decisions, specification, contractor selection, design, test and plant acceptance and operation. It treats reliability as an integrated methodology, explicitly describing life cycle management techniques as well as the basic elements of a total hardware development program, including: reliability parameters and design improvement attributes, reliability testing, reliability engineering and control. It describes how these elements can be defined during procurement, and implemented during design and development to yield reliable equipment. (author)
Yagi, Tetsuya; Shimada, Naoyuki; Nishida, Takehiro; Mitsuyama, Hiroshi; Miyashita, Motoharu
2013-03-01
Laser based displays, as pico to cinema laser projectors have gathered much attention because of wide gamut, low power consumption, and so on. Laser light sources for the displays are operated mainly in CW, and heat management is one of the big issues. Therefore, highly efficient operation is necessitated. Also the light sources for the displays are requested to be highly reliable. 638 nm broad stripe laser diode (LD) was newly developed for high efficiency and highly reliable operation. An AlGaInP/GaAs red LD suffers from low wall plug efficiency (WPE) due to electron overflow from an active layer to a p-cladding layer. Large optical confinement factor (Γ) design with AlInP cladding layers is adopted to improve the WPE. The design has a disadvantage for reliable operation because the large Γ causes high optical density and brings a catastrophic optical degradation (COD) at a front facet. To overcome the disadvantage, a window-mirror structure is also adopted in the LD. The LD shows WPE of 35% at 25°C, highest record in the world, and highly stable operation at 35°C, 550 mW up to 8,000 hours without any catastrophic optical degradation.
High reliability fuel in the US
International Nuclear Information System (INIS)
Neuhold, R.J.; Leggett, R.D.; Walters, L.C.; Matthews, R.B.
1986-05-01
The fuels development program of the United States is described for liquid metal reactors (LMR's). The experience base, status and future potential are discussed for the three systems - oxide, metal and carbide - that have proved to have high reliability. Information is presented showing burnup capability of the oxide fuel system in a large core, e.g., FFTF, to be 150 MWd/kgM with today's technology with the potential for a capability as high as 300 MWd/kgM. Data provided for the metal fuel system show 8 at. % being routinely achieved as the EBR-II driver fuel with good potential for extending this to 15 at. % since special test pins have already exceeded this burnup level. The data included for the carbide fuel system are from pin and assembly irradiations in EBR-II and FFTF, respectively. Burnup to 12 at. % appears readily achievable with burnups to 20 at. % being demonstrated in a few pins. Efforts continue on all three systems with the bulk of the activity on metal and oxide
Jones, Corinne A.; Hoffman, Matthew R.; Geng, Zhixian; Abdelhalim, Suzan M.; Jiang, Jack J.; McCulloch, Timothy M.
2014-01-01
Purpose: The purpose of this study was to investigate inter- and intrarater reliability among expert users, novice users, and speech-language pathologists with a semiautomated high-resolution manometry analysis program. We hypothesized that all users would have high intrarater reliability and high interrater reliability. Method: Three expert…
Seismic Performance of High-Ductile Fiber-Reinforced Concrete Short Columns
Directory of Open Access Journals (Sweden)
Mingke Deng
2018-01-01
Full Text Available This study mainly aims to investigate the effectiveness of high-ductile fiber-reinforced concrete (HDC as a means to enhance the seismic performance of short columns. Six HDC short columns and one reinforced concrete (RC short column were designed and tested under lateral cyclic loading. The influence of the material type (concrete or HDC, axial load, stirrup ratio, and shear span ratio on crack patterns, hysteresis behavior, shear strength, deformation capacity, energy dissipation, and stiffness degradation was presented and discussed, respectively. The test results show that the RC short column failed in brittle shear with poor energy dissipation, while using HDC to replace concrete can effectively improve the seismic behavior of the short columns. Compared with the RC short column, the shear strength of HDC specimens was improved by 12.6–30.2%, and the drift ratio and the energy dissipation increases were 56.9–88.5% and 237.7–336.7%, respectively, at the ultimate displacement. Additionally, the prediction model of the shear strength for RC columns based on GB50010-2010 (Chinese code can be safely adopted to evaluate the shear strength of HDC short columns.
The reliability and stability of visual working memory capacity.
Xu, Z; Adam, K C S; Fang, X; Vogel, E K
2018-04-01
Because of the central role of working memory capacity in cognition, many studies have used short measures of working memory capacity to examine its relationship to other domains. Here, we measured the reliability and stability of visual working memory capacity, measured using a single-probe change detection task. In Experiment 1, the participants (N = 135) completed a large number of trials of a change detection task (540 in total, 180 each of set sizes 4, 6, and 8). With large numbers of both trials and participants, reliability estimates were high (α > .9). We then used an iterative down-sampling procedure to create a look-up table for expected reliability in experiments with small sample sizes. In Experiment 2, the participants (N = 79) completed 31 sessions of single-probe change detection. The first 30 sessions took place over 30 consecutive days, and the last session took place 30 days later. This unprecedented number of sessions allowed us to examine the effects of practice on stability and internal reliability. Even after much practice, individual differences were stable over time (average between-session r = .76).
High reliable and Real-time Data Communication Network Technology for Nuclear Power Plant
International Nuclear Information System (INIS)
Jeong, K. I.; Lee, J. K.; Choi, Y. R.; Lee, J. C.; Choi, Y. S.; Cho, J. W.; Hong, S. B.; Jung, J. E.; Koo, I. S.
2008-03-01
As advanced digital Instrumentation and Control (I and C) system of NPP(Nuclear Power Plant) are being introduced to replace analog systems, a Data Communication Network(DCN) is becoming the important system for transmitting the data generated by I and C systems in NPP. In order to apply the DCNs to NPP I and C design, DCNs should conform to applicable acceptance criteria and meet the reliability and safety goals of the system. As response time is impacted by the selected protocol, network topology, network performance, and the network configuration of I and C system, DCNs should transmit a data within time constraints and response time required by I and C systems to satisfy response time requirements of I and C system. To meet these requirements, the DCNs of NPP I and C should be a high reliable and real-time system. With respect to high reliable and real-time system, several reports and techniques having influences upon the reliability and real-time requirements of DCNs are surveyed and analyzed
REMOTE SENSING APPLICATIONS WITH HIGH RELIABILITY IN CHANGJIANG WATER RESOURCE MANAGEMENT
Directory of Open Access Journals (Sweden)
L. Ma
2018-04-01
Full Text Available Remote sensing technology has been widely used in many fields. But most of the applications cannot get the information with high reliability and high accuracy in large scale, especially for the applications using automatic interpretation methods. We have designed an application-oriented technology system (PIR composed of a series of accurate interpretation techniques,which can get over 85 % correctness in Water Resource Management from the view of photogrammetry and expert knowledge. The techniques compose of the spatial positioning techniques from the view of photogrammetry, the feature interpretation techniques from the view of expert knowledge, and the rationality analysis techniques from the view of data mining. Each interpreted polygon is accurate enough to be applied to the accuracy sensitive projects, such as the Three Gorge Project and the South - to - North Water Diversion Project. In this paper, we present several remote sensing applications with high reliability in Changjiang Water Resource Management,including water pollution investigation, illegal construction inspection, and water conservation monitoring, etc.
Remote Sensing Applications with High Reliability in Changjiang Water Resource Management
Ma, L.; Gao, S.; Yang, A.
2018-04-01
Remote sensing technology has been widely used in many fields. But most of the applications cannot get the information with high reliability and high accuracy in large scale, especially for the applications using automatic interpretation methods. We have designed an application-oriented technology system (PIR) composed of a series of accurate interpretation techniques,which can get over 85 % correctness in Water Resource Management from the view of photogrammetry and expert knowledge. The techniques compose of the spatial positioning techniques from the view of photogrammetry, the feature interpretation techniques from the view of expert knowledge, and the rationality analysis techniques from the view of data mining. Each interpreted polygon is accurate enough to be applied to the accuracy sensitive projects, such as the Three Gorge Project and the South - to - North Water Diversion Project. In this paper, we present several remote sensing applications with high reliability in Changjiang Water Resource Management,including water pollution investigation, illegal construction inspection, and water conservation monitoring, etc.
Ultra Reliable Short Message Relaying with Wireless Power Transfer
López, Onel L. Alcaraz; Alves, Hirley; Souza, Richard Demo; Fernández, Evelio Martín García
2017-01-01
Abstract We consider a dual-hop wireless network where an energy constrained relay node first harvests energy through the received radio-frequency signal from the source, and then uses the harvested energy to forward the source’s information to the destination node. The throughput and delay metrics are investigated for a decode-and-forward relaying mechanism at finite blocklength regime and delay-limited transmission mode. We consider ultra-reliable communication scenarios under discussio...
International Nuclear Information System (INIS)
Kim, Hye Ji; Yoon, Yong Tae
2016-01-01
Highlights: • Application of TSFCL to interconnect systems with different reliabilities is proposed. • TSFCL protects a grid by preventing detrimental effects from being delivered through the interconnection line. • A high-speed TSFCL with high impedance for transmission systems is required to be developed. - Abstract: Interconnection of power systems is one effective way to improve power supply reliability. However, differences in the reliability of each power system create a greater obstacle for the stable interconnection of power systems, as after interconnection a high-reliability system is affected by frequent faults in low reliability side systems. Several power system interconnection methods, such as the back-to-back method and the installation of either transformers or series reactors, have been investigated to counteract the damage caused by faults in the other neighboring systems. However, these methods are uneconomical and require complex operational management plans. In this work, a high-speed trigger-type superconducting fault current limiter (TSFCL) with large-impedance is proposed as a solution to maintain reliability and power quality when a high reliability power system is interconnected with a low reliability power system. Through analysis of the reliability index for the numerical examples obtained from a PSCAD/EMTDC simulator, a high-speed TSFCL with a large-impedance is confirmed to be effective for the interconnection between power systems with different reliabilities.
Energy Technology Data Exchange (ETDEWEB)
Burgazzi, Luciano [ENEA-Centro Ricerche ' Ezio Clementel' , Advanced Physics Technology Division, Via Martiri di Monte Sole, 4, 40129 Bologna (Italy)]. E-mail: burgazzi@bologna.enea.it; Pierini, Paolo [INFN-Sezione di Milano, Laboratorio Acceleratori e Superconduttivita Applicata, Via Fratelli Cervi 201, I-20090 Segrate (MI) (Italy)
2007-04-15
The main effort of the present study is to analyze the availability and reliability of a high-performance linac (linear accelerator) conceived for Accelerator-Driven Systems (ADS) purpose and to suggest recommendations, in order both to meet the high operability goals and to satisfy the safety requirements dictated by the reactor system. Reliability Block Diagrams (RBD) approach has been considered for system modelling, according to the present level of definition of the design: component failure modes are assessed in terms of Mean Time Between Failure (MTBF) and Mean Time To Repair (MTTR), reliability and availability figures are derived, applying the current reliability algorithms. The lack of a well-established component database has been pointed out as the main issue related to the accelerator reliability assessment. The results, affected by the conservative character of the study, show a high margin for the improvement in terms of accelerator reliability and availability figures prediction. The paper outlines the viable path towards the accelerator reliability and availability enhancement process and delineates the most proper strategies. The improvement in the reliability characteristics along this path is shown as well.
International Nuclear Information System (INIS)
Burgazzi, Luciano; Pierini, Paolo
2007-01-01
The main effort of the present study is to analyze the availability and reliability of a high-performance linac (linear accelerator) conceived for Accelerator-Driven Systems (ADS) purpose and to suggest recommendations, in order both to meet the high operability goals and to satisfy the safety requirements dictated by the reactor system. Reliability Block Diagrams (RBD) approach has been considered for system modelling, according to the present level of definition of the design: component failure modes are assessed in terms of Mean Time Between Failure (MTBF) and Mean Time To Repair (MTTR), reliability and availability figures are derived, applying the current reliability algorithms. The lack of a well-established component database has been pointed out as the main issue related to the accelerator reliability assessment. The results, affected by the conservative character of the study, show a high margin for the improvement in terms of accelerator reliability and availability figures prediction. The paper outlines the viable path towards the accelerator reliability and availability enhancement process and delineates the most proper strategies. The improvement in the reliability characteristics along this path is shown as well
Energy Technology Data Exchange (ETDEWEB)
Mayer, Michael
2015-03-09
The scope of the thesis is the development of a method for improvement of efficient integrated management systems for high reliability organizations (HRO). A comprehensive analysis of severe accident prevention is performed. Severe accident management, mitigation measures and business continuity management are not included. High reliability organizations are complex and potentially dynamic organization forms that can be inherently dangerous like nuclear power plants, offshore platforms, chemical facilities, large ships or large aircrafts. A recursive generic management system model (RGM) was development based on the following factors: systemic and cybernetic Asepcts; integration of different management fields, high decision quality, integration of efficient methods of safety and risk analysis, integration of human reliability aspects, effectiveness evaluation and improvement.
A novel high reliability CMOS SRAM cell
Energy Technology Data Exchange (ETDEWEB)
Xie Chengmin; Wang Zhongfang; Wu Longsheng; Liu Youbao, E-mail: hglnew@sina.com [Computer Research and Design Department, Xi' an Microelectronic Technique Institutes, Xi' an 710054 (China)
2011-07-15
A novel 8T single-event-upset (SEU) hardened and high static noise margin (SNM) SRAM cell is proposed. By adding one transistor paralleled with each access transistor, the drive capability of pull-up PMOS is greater than that of the conventional cell and the read access transistors are weaker than that of the conventional cell. So the hold, read SNM and critical charge increase greatly. The simulation results show that the critical charge is almost three times larger than that of the conventional 6T cell by appropriately sizing the pull-up transistors. The hold and read SNM of the new cell increase by 72% and 141.7%, respectively, compared to the 6T design, but it has a 54% area overhead and read performance penalty. According to these features, this novel cell suits high reliability applications, such as aerospace and military. (semiconductor integrated circuits)
A novel high reliability CMOS SRAM cell
International Nuclear Information System (INIS)
Xie Chengmin; Wang Zhongfang; Wu Longsheng; Liu Youbao
2011-01-01
A novel 8T single-event-upset (SEU) hardened and high static noise margin (SNM) SRAM cell is proposed. By adding one transistor paralleled with each access transistor, the drive capability of pull-up PMOS is greater than that of the conventional cell and the read access transistors are weaker than that of the conventional cell. So the hold, read SNM and critical charge increase greatly. The simulation results show that the critical charge is almost three times larger than that of the conventional 6T cell by appropriately sizing the pull-up transistors. The hold and read SNM of the new cell increase by 72% and 141.7%, respectively, compared to the 6T design, but it has a 54% area overhead and read performance penalty. According to these features, this novel cell suits high reliability applications, such as aerospace and military. (semiconductor integrated circuits)
Qiu, Lei; Yuan, Shenfang; Shi, Xiaoling; Huang, Tianxiang
2012-07-01
Piezoelectric transducer (PZT) and Lamb wave based structural health monitoring (SHM) method have been widely studied for on-line SHM of high-performance structures. To monitor large-scale structures, a dense PZTs array is required. In order to improve the placement efficiency and reduce the wire burden of the PZTs array, the concept of the piezoelectric transducers layer (PSL) was proposed. The PSL consists of PZTs, a flexible interlayer with printed wires and signal input/output interface. For on-line SHM on real aircraft structures, there are two main issues on electromagnetic interference and connection reliability of the PSL. To address the issues, an electromagnetic shielding design method of the PSL to reduce spatial electromagnetic noise and crosstalk is proposed and a combined welding-cementation process based connection reliability design method is proposed to enhance the connection reliability between the PZTs and the flexible interlayer. Two experiments on electromagnetic interference suppression are performed to validate the shielding design of the PSL. The experimental results show that the amplitudes of the spatial electromagnetic noise and crosstalk output from the shielded PSL developed by this paper are - 15 dB and - 25 dB lower than those of the ordinary PSL, respectively. Other two experiments on temperature durability ( - 55 °C-80 °C ) and strength durability (160-1600μɛ, one million load cycles) are applied to the PSL to validate the connection reliability. The low repeatability errors (less than 3% and less than 5%, respectively) indicate that the developed PSL is of high connection reliability and long fatigue life.
Validity and reliability of short form-12 questionnaire in Iranian hemodialysis patients
DEFF Research Database (Denmark)
Pakpour, Amir H.; Nourozi, Saeedeh; Mølsted, Stig
2011-01-01
INTRODUCTION: The aim of the study was to assess the validity and reliability of the SF-12 questionnaire in a sample of Iranian patients undergoing hemodialysis. MATERIALS AND METHODS: One hundred and forty-four hemodialysis patients were included from dialysis centers in Zanjan, Iran, and were...... asked to complete the SF-12 and SF-36 questionnaires. An initial test-retest reliability evaluation was performed on a sample of 70 patients from the total group, with a retest interval of 14 days. Reliability was estimated by internal consistency and validity was assessed using known-group comparisons...... and construct validity on the patient group as a whole. A linear regression analysis was used to assess any variation in the physical component summary and mental component summary scores of the SF-36 with the respective component summary scores of the SF-12. In addition, the factor structure...
Technology Improvement for the High Reliability LM-2F Launch Vehicle
Institute of Scientific and Technical Information of China (English)
QIN Tong; RONG Yi; ZHENG Liwei; ZHANG Zhi
2017-01-01
The Long March 2F (LM-2F) launch vehicle,the only launch vehicle designed for manned space flight in China,successfully launched the Tiangong 2 space laboratory and the Shenzhou ll manned spaceship into orbits in 2016 respectively.In this study,it introduces the technological improvements for enhancing the reliability of the LM-2F launch vehicle in the aspects of general technology,control system,manufacture and ground support system.The LM2F launch vehicle will continue to provide more contributions to the Chinese Space Station Project with its high reliability and 100% success rate.
Toward reliable and repeatable automated STEM-EDS metrology with high throughput
Zhong, Zhenxin; Donald, Jason; Dutrow, Gavin; Roller, Justin; Ugurlu, Ozan; Verheijen, Martin; Bidiuk, Oleksii
2018-03-01
New materials and designs in complex 3D architectures in logic and memory devices have raised complexity in S/TEM metrology. In this paper, we report about a newly developed, automated, scanning transmission electron microscopy (STEM) based, energy dispersive X-ray spectroscopy (STEM-EDS) metrology method that addresses these challenges. Different methodologies toward repeatable and efficient, automated STEM-EDS metrology with high throughput are presented: we introduce the best known auto-EDS acquisition and quantification methods for robust and reliable metrology and present how electron exposure dose impacts the EDS metrology reproducibility, either due to poor signalto-noise ratio (SNR) at low dose or due to sample modifications at high dose conditions. Finally, we discuss the limitations of the STEM-EDS metrology technique and propose strategies to optimize the process both in terms of throughput and metrology reliability.
A short form of the neonatal intensive care unit family needs inventory
Directory of Open Access Journals (Sweden)
Elisabete Alves
2016-02-01
Full Text Available ABSTRACT OBJECTIVE: The identification of parental needs in Neonatal Intensive Care Units is essential to design and implement family-centered care. This article aims to validate the Neonatal Intensive Care Units Family Needs Inventory for the Portuguese population, and to propose a Short Form. METHODS: A linguistic adaptation of the Neonatal Intensive Care Units Family Needs Inventory, a self-report scale with 56-items, was performed. The instrument was administered to 211 parents of infants hospitalized in all level III Neonatal Intensive Care Units in the North of Portugal, 15-22 days after admission (July of 2013-June of 2014. The number of items needed to achieve reliability close to 0.8 was calculated using by the Spearman-Brown formula. The global goodness of fit of the scale was evaluated using the comparative fit index. Construct validity was assessed through association of each dimension score with socio-demographic and obstetric characteristics. RESULTS: Exploratory factor analysis revealed two dimensions, one focused on parents' needs and another on the infant's needs. To compose the Short Form Inventory, items with ceiling effect were eliminated and 22 items were submitted to confirmatory analysis, which supported the existence of two dimensions (CFI = 0.925. The Short Form showed a high degree of reliability (alpha ≥ 0.76. Less educated and older parents more frequently attributed a significantly higher importance to parent-centered needs, while parents of multiples revealed a tendency to value infant-centered needs. CONCLUSIONS: The Short Form of the Neonatal Intensive Care Units Family Needs Inventory is a brief, simple, and valid instrument with a high degree of reliability. Further studies are needed to explore associations with practices of family-centered care.
Gehling, Julia; Mainka, Tina; Vollert, Jan; Pogatzki-Zahn, Esther M; Maier, Christoph; Enax-Krumova, Elena K
2016-08-05
Conditioned Pain Modulation (CPM) is often used to assess human descending pain inhibition. Nine different studies on the test-retest-reliability of different CPM paradigms have been published, but none of them has investigated the commonly used heat-cold-pain method. The results vary widely and therefore, reliability measures cannot be extrapolated from one CPM paradigm to another. Aim of the present study was to analyse the test-retest-reliability of the common heat-cold-pain method and its correlation to pain thresholds. We tested the short-term test-retest-reliability within 40 ± 19.9 h using a cold-water immersion (10 °C, left hand) as conditioning stimulus (CS) and heat pain (43-49 °C, pain intensity 60 ± 5 on the 101-point numeric rating scale, right forearm) as test stimulus (TS) in 25 healthy right-handed subjects (12females, 31.6 ± 14.1 years). The TS was applied 30s before (TSbefore), during (TSduring) and after (TSafter) the 60s CS. The difference between the pain ratings for TSbefore and TSduring represents the early CPM-effect, between TSbefore and TSafter the late CPM-effect. Quantitative sensory testing (QST, DFNS protocol) was performed on both sessions before the CPM assessment. paired t-tests, Intraclass correlation coefficient (ICC), standard error of measurement (SEM), smallest real difference (SRD), Pearson's correlation, Bland-Altman analysis, significance level p Pain ratings during CPM correlated significantly (ICC: 0.411…0.962) between both days, though ratings for TSafter were lower on day 2 (p pain thresholds. The short-term test-retest-reliability of the early CPM-effect using the heat-cold-pain method in healthy subjects achieved satisfying results in terms of the ICC. The SRD of the early CPM effect showed that an individual change of > 20 NRS can be attributed to a real change rather than chance. The late CPM-effect was weaker and not reliable.
Uncovering the mutation-fixation correlation in short lineages
Directory of Open Access Journals (Sweden)
Vallender Eric J
2007-09-01
Full Text Available Abstract Background We recently reported a highly unexpected positive correlation between the fixation probability of nonsynonymous mutations (estimated by ω and neutral mutation rate (estimated by Ks in mammalian lineages. However, this positive correlation was observed for lineages with relatively long divergence time such as the human-mouse lineage, and was not found for very short lineages such as the human-chimpanzee lineage. It was previously unclear how to interpret this discrepancy. It may indicate that the positive correlation between ω and Ks in long lineages is a false finding. Alternatively, it may reflect a biologically meaningful difference between various lineages. Finally, the lack of positive correlation in short lineages may be the result of methodological artifacts. Results Here we show that a strong positive correlation can indeed be seen in short lineages when a method was introduced to correct for the inherently high levels of stochastic noise in the use of Ks as an estimator of neutral mutation rate. Thus, the previously noted lack of positive correlation between ω and Ks in short lineages is due to stochastic noise in Ks that makes it a far less reliable estimator of neutral mutation rate in short lineages as compared to long lineages. Conclusion A positive correlation between ω and Ks can be observed in all mammalian lineages for which large amounts of sequence data are available, including very short lineages. It confirms the authenticity of this highly unexpected correlation, and argues that the correction likely applies broadly across all mammals and perhaps even non-mammalian species.
Bearing Procurement Analysis Method by Total Cost of Ownership Analysis and Reliability Prediction
Trusaji, Wildan; Akbar, Muhammad; Sukoyo; Irianto, Dradjad
2018-03-01
In making bearing procurement analysis, price and its reliability must be considered as decision criteria, since price determines the direct cost as acquisition cost and reliability of bearing determine the indirect cost such as maintenance cost. Despite the indirect cost is hard to identify and measured, it has high contribution to overall cost that will be incurred. So, the indirect cost of reliability must be considered when making bearing procurement analysis. This paper tries to explain bearing evaluation method with the total cost of ownership analysis to consider price and maintenance cost as decision criteria. Furthermore, since there is a lack of failure data when bearing evaluation phase is conducted, reliability prediction method is used to predict bearing reliability from its dynamic load rating parameter. With this method, bearing with a higher price but has higher reliability is preferable for long-term planning. But for short-term planning the cheaper one but has lower reliability is preferable. This contextuality can give rise to conflict between stakeholders. Thus, the planning horizon needs to be agreed by all stakeholder before making a procurement decision.
Teixeira Martins, Marcia C; Jaceldo-Siegl, Karen; Fan, Jing; Singh, Pramil; Fraser, Gary E
2015-01-01
Past dietary patterns may be more important than recent dietary patterns in the aetiology of chronic diseases because of the long latency in their development. We developed an instrument to recall vegetarian dietary patterns during the lifetime and examined its reliability of recall over 5·3 and 32·6 years on average. The short-term/5-year recall ability study (5-RAS) was done using 24 690 participants from the cohort of the Adventist Health Study-2 (mean age 62·2 years). The long-term/33-year recall ability study (33-RAS) included an overlap population of 1721 individuals who joined the Adventist Health Study-1 and Adventist Health Study-2 (mean age 72·5 years). Spearman correlation coefficients for recall of vegetarian status were 0·78 and 0·72 for the 5-RAS and 33-RAS, respectively, when compared with 'reference' data. For both time periods sensitivity and positive predictive values were highest for the lacto-ovo-vegetarian and non-vegetarian patterns (vegans, lacto-ovo-vegetarians, pesco-vegetarians, semi-vegetarians and non-vegetarians). In the 5-RAS analyses, male, non-black, younger, and more educated participants, lifetime Adventists, and those with more stability of consumption of animal products generally showed higher recall ability. Somewhat similar tendencies were shown for the 33-RAS analyses. Our findings show that the instrument has higher reliability for recalled lacto-ovo-vegetarian and non-vegetarian than for vegan, semi- and pesco-vegetarian dietary patterns in both short- and long-term recalls. This is in part because these last dietary patterns were greatly contaminated by recalls that correctly would have belonged in the adjoining category that consumed more animal products.
System principles, mathematical models and methods to ensure high reliability of safety systems
Zaslavskyi, V.
2017-04-01
Modern safety and security systems are composed of a large number of various components designed for detection, localization, tracking, collecting, and processing of information from the systems of monitoring, telemetry, control, etc. They are required to be highly reliable in a view to correctly perform data aggregation, processing and analysis for subsequent decision making support. On design and construction phases of the manufacturing of such systems a various types of components (elements, devices, and subsystems) are considered and used to ensure high reliability of signals detection, noise isolation, and erroneous commands reduction. When generating design solutions for highly reliable systems a number of restrictions and conditions such as types of components and various constrains on resources should be considered. Various types of components perform identical functions; however, they are implemented using diverse principles, approaches and have distinct technical and economic indicators such as cost or power consumption. The systematic use of different component types increases the probability of tasks performing and eliminates the common cause failure. We consider type-variety principle as an engineering principle of system analysis, mathematical models based on this principle, and algorithms for solving optimization problems of highly reliable safety and security systems design. Mathematical models are formalized in a class of two-level discrete optimization problems of large dimension. The proposed approach, mathematical models, algorithms can be used for problem solving of optimal redundancy on the basis of a variety of methods and control devices for fault and defects detection in technical systems, telecommunication networks, and energy systems.
Oyeyemi, Adewale L; Oyeyemi, Adetoyeje Y; Adegoke, Babatunde O; Oyetoke, Fatima O; Aliyu, Habeeb N; Aliyu, Salamatu U; Rufai, Adamu A
2011-11-22
Accurate assessment of physical activity is important in determining the risk for chronic diseases such as cardiovascular disease, stroke, type 2 diabetes, cancer and obesity. The absence of culturally relevant measures in indigenous languages could pose challenges to epidemiological studies on physical activity in developing countries. The purpose of this study was to translate and cross-culturally adapt the Short International Physical Activity Questionnaire (IPAQ-SF) to the Hausa language, and to evaluate the validity and reliability of the Hausa version of IPAQ-SF in Nigeria. The English IPAQ-SF was translated into the Hausa language, synthesized, back translated, and subsequently subjected to expert committee review and pre-testing. The final product (Hausa IPAQ-SF) was tested in a cross-sectional study for concurrent (correlation with the English version) and construct validity, and test-retest reliability in a sample of 102 apparently healthy adults. The Hausa IPAQ-SF has good concurrent validity with Spearman correlation coefficients (ρ) ranging from 0.78 for vigorous activity (Min Week-1) to 0.92 for total physical activity (Metabolic Equivalent of Task [MET]-Min Week-1), but poor construct validity, with cardiorespiratory fitness (ρ = 0.21, p = 0.01) and body mass index (ρ = 0.22, p = 0.04) significantly correlated with only moderate activity and sitting time (Min Week-1), respectively. Reliability was good for vigorous (ICC = 0.73, 95% C.I = 0.55-0.84) and total physical activity (ICC = 0.61, 95% C.I = 0.47-0.72), but fair for moderate activity (ICC = 0.33, 95% C.I = 0.12-0.51), and few meaningful differences were found in the gender and socioeconomic status specific analyses. The Hausa IPAQ-SF has acceptable concurrent validity and test-retest reliability for vigorous-intensity activity, walking, sitting and total physical activity, but demonstrated only fair construct validity for moderate and sitting activities. The Hausa IPAQ-SF can be used for
International Nuclear Information System (INIS)
Qiu, Lei; Yuan, Shenfang; Shi, Xiaoling; Huang, Tianxiang
2012-01-01
Piezoelectric transducer (PZT) and Lamb wave based structural health monitoring (SHM) method have been widely studied for on-line SHM of high-performance structures. To monitor large-scale structures, a dense PZTs array is required. In order to improve the placement efficiency and reduce the wire burden of the PZTs array, the concept of the piezoelectric transducers layer (PSL) was proposed. The PSL consists of PZTs, a flexible interlayer with printed wires and signal input/output interface. For on-line SHM on real aircraft structures, there are two main issues on electromagnetic interference and connection reliability of the PSL. To address the issues, an electromagnetic shielding design method of the PSL to reduce spatial electromagnetic noise and crosstalk is proposed and a combined welding–cementation process based connection reliability design method is proposed to enhance the connection reliability between the PZTs and the flexible interlayer. Two experiments on electromagnetic interference suppression are performed to validate the shielding design of the PSL. The experimental results show that the amplitudes of the spatial electromagnetic noise and crosstalk output from the shielded PSL developed by this paper are − 15 dB and − 25 dB lower than those of the ordinary PSL, respectively. Other two experiments on temperature durability ( − 55 °C–80 °C ) and strength durability (160–1600με, one million load cycles) are applied to the PSL to validate the connection reliability. The low repeatability errors (less than 3% and less than 5%, respectively) indicate that the developed PSL is of high connection reliability and long fatigue life. (paper)
76 FR 72203 - Voltage Coordination on High Voltage Grids; Notice of Reliability Workshop Agenda
2011-11-22
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. AD12-5-000] Voltage Coordination on High Voltage Grids; Notice of Reliability Workshop Agenda As announced in the Notice of Staff..., from 9 a.m. to 4:30 p.m. to explore the interaction between voltage control, reliability, and economic...
High Reliability Prototype Quadrupole for the Next Linear Collider
International Nuclear Information System (INIS)
Spencer, Cherrill M
2001-01-01
The Next Linear Collider (NLC) will require over 5600 magnets, each of which must be highly reliable and/or quickly repairable in order that the NLC reach its 85% overall availability goal. A multidiscipline engineering team was assembled at SLAC to develop a more reliable electromagnet design than historically had been achieved at SLAC. This team carried out a Failure Mode and Effects Analysis (FMEA) on a standard SLAC quadrupole magnet system. They overcame a number of longstanding design prejudices, producing 10 major design changes. This paper describes how a prototype magnet was constructed and the extensive testing carried out on it to prove full functionality with an improvement in reliability. The magnet's fabrication cost will be compared to the cost of a magnet with the same requirements made in the historic SLAC way. The NLC will use over 1600 of these 12.7 mm bore quadrupoles with a range of integrated strengths from 0.6 to 132 Tesla, a maximum gradient of 135 Tesla per meter, an adjustment range of 0 to -20% and core lengths from 324 mm to 972 mm. The magnetic center must remain stable to within 1 micron during the 20% adjustment. A magnetic measurement set-up has been developed that can measure sub-micron shifts of a magnetic center. The prototype satisfied the center shift requirement over the full range of integrated strengths
Numerical challenges of short range wake field calculations
Energy Technology Data Exchange (ETDEWEB)
Lau, Thomas; Gjonaj, Erion; Weiland, Thomas [Technische Universitaet Darmstadt (Germany). Institut fuer Theorie Elektromagnetischer Felder (TEMF)
2011-07-01
For present and future accelerator projects with ultra short bunches the accurate and reliable calculation of short range wake fields is an important issue. However, the numerical calculation of short range wake fields is a numerical challenging task. The presentation gives an overview over the numerical challenges and techniques for short range wake field calculations. Finally, some simulation results obtained by the program PBCI developed at the TU Darmstadt are presented.
International Nuclear Information System (INIS)
Schafft, H.A.
1977-01-01
Summaries are presented of 12 invited talks on the following topics: the procurement and assurance of high reliability electronic parts, leak rate and moisture measurements, pacemaker batteries, and pacemaker leads. The workshop, second in a series, was held in response to strong interest expressed by the pacemaker community to address technical questions relevant to the enhancement and assurance of cardiac pacemaker reliability. Discussed at the workshop were a process validation wafer concept for assuring process uniformity in device chips; screen tests for assuring reliable electronic parts; reliability prediction; reliability comparison of semiconductor technologies; mechanisms of short-circuiting dendritic growths; details of helium and radioisotope leak test methods; a study to correlate package leak rates, as measured with test gasses, and actual moisture infusion; battery life prediction; microcalorimetric measurements to nondestructively evaluate batteries for pacemakers; and an engineer's and a physician's view of the present status of pacemaker leads. References are included with most of the reports
Huang, Min H; Miller, Kara; Smith, Kristin; Fredrickson, Kayle; Shilling, Tracy
2016-01-01
Cancer is primarily a disease of older adults. About 77% of all cancers are diagnosed in persons aged 55 years and older. Cancer and its treatment can cause diverse sequelae impacting body systems underlying balance control. No study has examined the psychometric properties of balance assessment tools in older cancer survivors, presenting a significant challenge in the selection of outcome measures for clinicians treating this fast-growing population. This study aimed to determine the reliability, validity, and minimal detectable change (MDC) of the Balance Evaluation System Test (BESTest), Mini-Balance Evaluation Systems Test (Mini-BESTest), and Brief-Balance Evaluation Systems Test (Brief-BESTest) in community-dwelling older cancer survivors. This study was a cross-sectional design. Twenty breast and 8 prostate cancer survivors participated [age (SD) = 68.4 (8.13) years]. The BESTest and Activity-specific Balance Confidence (ABC) Scale were administered during the first session. Scores of Mini-BESTest and Brief-BESTest were extracted on the basis of the scores of BESTest. The BESTest was repeated within 1 to 2 weeks by the same rater to determine the test-retest reliability. For the analysis of the inter-rater reliability, 21 participants were randomly selected to be evaluated by 2 raters. A primary rater administered the test. The 2 raters independently and concurrently scored the performance of the participants. Each rater recorded the ratings separately on the scoring sheet. No discussion among the raters was allowed throughout the testing. Intraclass correlation coefficients (ICCs), standard error of measurement, minimal detectable change (MDC), and Bland-Altman plots were calculated. Concurrent validity of these balance tests with the ABC Scale was examined using the Spearman correlation. The BESTest, Mini-BESTest, and Brief-BESTest had high test-retest (ICC = 0.90-0.94) and interrater reliability (ICC = 0.86-0.96), small standard error of measurement (0
A criterion of the performance of thermometric systems of high metrological reliability
International Nuclear Information System (INIS)
Sal'nikov, N.L.; Filimonov, E.V.
1995-01-01
Monitoring temperature regimes is an important part of ensuring the operational safety of a nuclear power plant. Therefore, high standards are imposed upon the reliability of the primary information on the heat field of the object obtained from different sensors, and it is urgent to develop methods of evaluating the metrological reliability of these sensors. THe main sources of thermometric information at nuclear power plants are contact temperature sensors, the most widely used of these being thermoelectric converters (TEC) and thermal resistance converters (TRC)
Fuel reliability experience in Finland
International Nuclear Information System (INIS)
Kekkonen, L.
2015-01-01
Four nuclear reactors have operated in Finland now for 35-38 years. The two VVER-440 units at Loviisa Nuclear Power Plant are operated by Fortum and two BWR’s in Olkiluoto are operated by Teollisuuden Voima Oyj (TVO). The fuel reliability experience of the four reactors operating currently in Finland has been very good and the fuel failure rates have been very low. Systematic inspection of spent fuel assemblies, and especially all failed assemblies, is a good practice that is employed in Finland in order to improve fuel reliability and operational safety. Investigation of the root cause of fuel failures is important in developing ways to prevent similar failures in the future. The operational and fuel reliability experience at the Loviisa Nuclear Power Plant has been reported also earlier in the international seminars on WWER Fuel Performance, Modelling and Experimental Support. In this paper the information on fuel reliability experience at Loviisa NPP is updated and also a short summary of the fuel reliability experience at Olkiluoto NPP is given. Keywords: VVER-440, fuel reliability, operational experience, poolside inspections, fuel failure identification. (author)
Shou, Juan; Ren, Limin; Wang, Haitang; Yan, Fei; Cao, Xiaoyun; Wang, Hui; Wang, Zhiliang; Zhu, Shanzhu; Liu, Yao
2016-04-01
The 12-item Short-Form Health Survey (SF-12) is the abridged practical version of SF-36. This cross-sectional study was aimed to assess the reliability and validity of SF-12 for the health status of Chinese community elderly population. The Chinese community elderly people in Xujiahui district of Shanghai were investigated. The internal consistency reliability was assessed using Cronbach's alpha and split-half reliability coefficients. Construct validity was analyzed using exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). Spearman's correlation coefficient (ρ) was used for the evaluation of criterion, convergent, and discriminant validity with Spearman's ρ ≥ 0.4 as satisfactory. Comparisons of the SF-12 summary scores among populations that differed in demographics were performed for discriminant validity. Total 1343 individuals aged ≥60 and reliability coefficient (0.812) reflected satisfactory internal consistency reliability of SF-12. EFA extracted a two-factor model (physical and mental health). About 60.7 % of the total variance was explained by the two factors. CFA showed that the two-factor solution provided a good fit to the data. Good convergent validity and discriminant validity of SF-12 were proved by the correction analyses (Spearman's ρ > 0.4) and the comparisons of the SF-12 summary scores among populations (P 0.4, P reliability and validity in measuring health status of Chinese community elderly population in Xujiahui district of Shanghai.
Energy Technology Data Exchange (ETDEWEB)
Susnik, J [Institut Jozef Stefan, Ljubljana (Yugoslavia)
1979-07-01
First a short report on development of computer programs for the reliability evaluation and the findings regarding the adequate reliability of Nuclear Power Plant safety systems are given. Then evaluation of the general NPP availability situation is discussed and suggestions for planning and achieving an adequate high availability are presented. (author)
Tang, Jennifer Yee-Man; Ho, Andy Hau-Yan; Luo, Hao; Wong, Gloria Hoi-Yan; Lau, Bobo Hi-Po; Lum, Terry Yat-Sang; Cheung, Karen Siu-Lan
2016-09-01
The present study aimed to develop and validate a Cantonese short version of the Zarit Burden Interview (CZBI-Short) for Hong Kong Chinese dementia caregivers. The 12-item Zarit Burden Interview (ZBI) was translated into spoken Cantonese and back-translated by two bilingual research assistants and face validated by a panel of experts. Five hundred Chinese dementia caregivers showing signs of stress reported their burden using the translated ZBI and rated their depressive symptoms, overall health, and care recipients' physical functioning and behavioral problems. The factor structure of the translated scale was identified using principal component analysis and confirmatory factor analysis; internal consistency and item-total correlations were assessed; and concurrent validity was tested by correlating the ZBI with depressive symptoms, self-rated health, and care recipients' physical functioning and behavioral problems. The principal component analysis resulted in 11 items loading on a three-factor model comprised role strain, self-criticism, and negative emotion, which accounted for 59% of the variance. The confirmatory factor analysis supported the three-factor model (CZBI-Short) that explained 61% of the total variance. Cronbach's alpha (0.84) and item-total correlations (rho = 0.39-0.71) indicated CZBI-Short had good reliability. CZBI-Short showed correlations with depressive symptoms (r = 0.50), self-rated health (r = -0.26) and care recipients' physical functioning (r = 0.18-0.26) and disruptive behaviors (r = 0.36). The 12-item CZBI-Short is a concise, reliable, and valid instrument to assess burden in Chinese dementia caregivers in clinical and social care settings.
Baumbach, S.; Pricking, S.; Overbuschmann, J.; Nutsch, S.; Kleinbauer, J.; Gebs, R.; Tan, C.; Scelle, R.; Kahmann, M.; Budnicki, A.; Sutter, D. H.; Killi, A.
2017-02-01
Multi-megawatt ultrafast laser systems at micrometer wavelength are commonly used for material processing applications, including ablation, cutting and drilling of various materials or cleaving of display glass with excellent quality. There is a need for flexible and efficient beam guidance, avoiding free space propagation of light between the laser head and the processing unit. Solid core step index fibers are only feasible for delivering laser pulses with peak powers in the kW-regime due to the optical damage threshold in bulk silica. In contrast, hollow core fibers are capable of guiding ultra-short laser pulses with orders of magnitude higher peak powers. This is possible since a micro-structured cladding confines the light within the hollow core and therefore minimizes the spatial overlap between silica and the electro-magnetic field. We report on recent results of single-mode ultra-short pulse delivery over several meters in a lowloss hollow core fiber packaged with industrial connectors. TRUMPF's ultrafast TruMicro laser platforms equipped with advanced temperature control and precisely engineered opto-mechanical components provide excellent position and pointing stability. They are thus perfectly suited for passive coupling of ultra-short laser pulses into hollow core fibers. Neither active beam launching components nor beam trackers are necessary for a reliable beam delivery in a space and cost saving packaging. Long term tests with weeks of stable operation, excellent beam quality and an overall transmission efficiency of above 85 percent even at high average power confirm the reliability for industrial applications.
High-order harmonic generation with short-pulse lasers
International Nuclear Information System (INIS)
Schafer, K.J.; Krause, J.L.; Kulander, K.C.
1992-12-01
Recent progress in the understanding of high-order harmonic conversion from atoms and ions exposed to high-intensity, short-pulse optical lasers is reviewed. We find that ions can produce harmonics comparable in strength to those obtained from neutral atoms, and that the emission extends to much higher order. Simple scaling laws for the strength of the harmonic emission and the maximium observable harmonic are suggested. These results imply that the photoemission observed in recent experiments in helium and neon contains contributions from ions as well as neutrals
High Average Power, High Energy Short Pulse Fiber Laser System
Energy Technology Data Exchange (ETDEWEB)
Messerly, M J
2007-11-13
Recently continuous wave fiber laser systems with output powers in excess of 500W with good beam quality have been demonstrated [1]. High energy, ultrafast, chirped pulsed fiber laser systems have achieved record output energies of 1mJ [2]. However, these high-energy systems have not been scaled beyond a few watts of average output power. Fiber laser systems are attractive for many applications because they offer the promise of high efficiency, compact, robust systems that are turn key. Applications such as cutting, drilling and materials processing, front end systems for high energy pulsed lasers (such as petawatts) and laser based sources of high spatial coherence, high flux x-rays all require high energy short pulses and two of the three of these applications also require high average power. The challenge in creating a high energy chirped pulse fiber laser system is to find a way to scale the output energy while avoiding nonlinear effects and maintaining good beam quality in the amplifier fiber. To this end, our 3-year LDRD program sought to demonstrate a high energy, high average power fiber laser system. This work included exploring designs of large mode area optical fiber amplifiers for high energy systems as well as understanding the issues associated chirped pulse amplification in optical fiber amplifier systems.
Short-term memory for tactile and temporal stimuli in a shared-attention recall task.
Bowers, R L; Mollenhauer, M S; Luxford, J
1990-06-01
The present study examined short-term memory for tactile and temporal stimuli. Subjects were required to touch three-dimensional sample objects of different shapes and textures, presented for three durations: short, medium, or long. After the sample duration elapsed, a retention interval (5 sec.-20 sec.) occurred followed by a recall test for one of the sample dimensions of shape, texture, or time, across trials. Analysis showed that accuracy for shape and texture was high throughout testing (95-99%), but memory for perceived duration was relatively poor (60%). Further analysis indicated that poor recall on the time dimension was isolated to the medium and long samples; accuracy for short durations was consistently high (90%). In addition, a reliable response bias emerged; subjects recalled durations shorter than the actual duration presented. The results were discussed in terms of two lines of research, one indicating that haptic short-term memory is strong relative to other memory systems, and the other suggesting that the choose-short bias occurs across species.
The Accelerator Reliability Forum
Lüdeke, Andreas; Giachino, R
2014-01-01
A high reliability is a very important goal for most particle accelerators. The biennial Accelerator Reliability Workshop covers topics related to the design and operation of particle accelerators with a high reliability. In order to optimize the over-all reliability of an accelerator one needs to gather information on the reliability of many different subsystems. While a biennial workshop can serve as a platform for the exchange of such information, the authors aimed to provide a further channel to allow for a more timely communication: the Particle Accelerator Reliability Forum [1]. This contribution will describe the forum and advertise it’s usage in the community.
Reliability and validity of a short form household food security scale in a Caribbean community
Directory of Open Access Journals (Sweden)
Mahabir Deepak
2004-06-01
Full Text Available Abstract Background We evaluated the reliability and validity of the short form household food security scale in a different setting from the one in which it was developed. Methods The scale was interview administered to 531 subjects from 286 households in north central Trinidad in Trinidad and Tobago, West Indies. We evaluated the six items by fitting item response theory models to estimate item thresholds, estimating agreement among respondents in the same households and estimating the slope index of income-related inequality (SII after adjusting for age, sex and ethnicity. Results Item-score correlations ranged from 0.52 to 0.79 and Cronbach's alpha was 0.87. Item responses gave within-household correlation coefficients ranging from 0.70 to 0.78. Estimated item thresholds (standard errors from the Rasch model ranged from -2.027 (0.063 for the 'balanced meal' item to 2.251 (0.116 for the 'hungry' item. The 'balanced meal' item had the lowest threshold in each ethnic group even though there was evidence of differential functioning for this item by ethnicity. Relative thresholds of other items were generally consistent with US data. Estimation of the SII, comparing those at the bottom with those at the top of the income scale, gave relative odds for an affirmative response of 3.77 (95% confidence interval 1.40 to 10.2 for the lowest severity item, and 20.8 (2.67 to 162.5 for highest severity item. Food insecurity was associated with reduced consumption of green vegetables after additionally adjusting for income and education (0.52, 0.28 to 0.96. Conclusions The household food security scale gives reliable and valid responses in this setting. Differing relative item thresholds compared with US data do not require alteration to the cut-points for classification of 'food insecurity without hunger' or 'food insecurity with hunger'. The data provide further evidence that re-evaluation of the 'balanced meal' item is required.
SABIL, SYAHRIANA
2015-01-01
2015 SYAHRIANA SABIL (I 111 11 273). Pasteurisasi High Temperature Short Time (HTST) Susu terhadap Listeria monocytogenes pada Penyimpanan Refrigerator. Dibimbing oleh RATMAWATI MALAKA dan FARIDA NUR YULIATI. Pasteurisasi High Temperature Short Time (HTST) merupakan proses pemanasan susu di bawah titik didih yang diharapkan dapat membunuh Listeria monocytogenes (L. monocytogenes) karena bersifat patogen dan mengakibatkan listeriosis yang merupakan penyakit zoonosis. Tu...
Implementation of checklists in health care; learning from high-reliability organisations
Directory of Open Access Journals (Sweden)
Lossius Hans
2011-10-01
Full Text Available Abstract Background Checklists are common in some medical fields, including surgery, intensive care and emergency medicine. They can be an effective tool to improve care processes and reduce mortality and morbidity. Despite the seemingly rapid acceptance and dissemination of the checklist, there are few studies describing the actual process of developing and implementing such tools in health care. The aim of this study is to explore the experiences from checklist development and implementation in a group of non-medical, high reliability organisations (HROs. Method A qualitative study based on key informant interviews and field visits followed by a Delphi approach. Eight informants, each with 10-30 years of checklist experience, were recruited from six different HROs. Results The interviews generated 84 assertions and recommendations for checklist implementation. To achieve checklist acceptance and compliance, there must be a predefined need for which a checklist is considered a well suited solution. The end-users ("sharp-end" are the key stakeholders throughout the development and implementation process. Proximity and ownership must be assured through a thorough and wise process. All informants underlined the importance of short, self-developed, and operationally-suited checklists. Simulation is a valuable and widely used method for training, revision, and validation. Conclusion Checklists have been a cornerstone of safety management in HROs for nearly a century, and are becoming increasingly popular in medicine. Acceptance and compliance are crucial for checklist implementation in health care. Experiences from HROs may provide valuable input to checklist implementation in healthcare.
Utilization of Short-Simulations for Tuning High-Resolution Climate Model
Lin, W.; Xie, S.; Ma, P. L.; Rasch, P. J.; Qian, Y.; Wan, H.; Ma, H. Y.; Klein, S. A.
2016-12-01
Many physical parameterizations in atmospheric models are sensitive to resolution. Tuning the models that involve a multitude of parameters at high resolution is computationally expensive, particularly when relying primarily on multi-year simulations. This work describes a complementary set of strategies for tuning high-resolution atmospheric models, using ensembles of short simulations to reduce the computational cost and elapsed time. Specifically, we utilize the hindcast approach developed through the DOE Cloud Associated Parameterization Testbed (CAPT) project for high-resolution model tuning, which is guided by a combination of short (tests have been found to be effective in numerous previous studies in identifying model biases due to parameterized fast physics, and we demonstrate that it is also useful for tuning. After the most egregious errors are addressed through an initial "rough" tuning phase, longer simulations are performed to "hone in" on model features that evolve over longer timescales. We explore these strategies to tune the DOE ACME (Accelerated Climate Modeling for Energy) model. For the ACME model at 0.25° resolution, it is confirmed that, given the same parameters, major biases in global mean statistics and many spatial features are consistent between Atmospheric Model Intercomparison Project (AMIP)-type simulations and CAPT-type hindcasts, with just a small number of short-term simulations for the latter over the corresponding season. The use of CAPT hindcasts to find parameter choice for the reduction of large model biases dramatically improves the turnaround time for the tuning at high resolution. Improvement seen in CAPT hindcasts generally translates to improved AMIP-type simulations. An iterative CAPT-AMIP tuning approach is therefore adopted during each major tuning cycle, with the former to survey the likely responses and narrow the parameter space, and the latter to verify the results in climate context along with assessment in
Offshore compression system design for low cost high and reliability
Energy Technology Data Exchange (ETDEWEB)
Castro, Carlos J. Rocha de O.; Carrijo Neto, Antonio Dias; Cordeiro, Alexandre Franca [Chemtech Engineering Services and Software Ltd., Rio de Janeiro, RJ (Brazil). Special Projects Div.], Emails: antonio.carrijo@chemtech.com.br, carlos.rocha@chemtech.com.br, alexandre.cordeiro@chemtech.com.br
2010-07-01
In the offshore oil fields, the oil streams coming from the wells usually have significant amounts of gas. This gas is separated at low pressure and has to be compressed to the export pipeline pressure, usually at high pressure to reduce the needed diameter of the pipelines. In the past, this gases where flared, but nowadays there are a increasing pressure for the energy efficiency improvement of the oil rigs and the use of this gaseous fraction. The most expensive equipment of this kind of plant are the compression and power generation systems, being the second a strong function of the first, because the most power consuming equipment are the compressors. For this reason, the optimization of the compression system in terms of efficiency and cost are determinant to the plant profit. The availability of the plants also have a strong influence in the plant profit, specially in gas fields where the products have a relatively low aggregated value, compared to oil. Due this, the third design variable of the compression system becomes the reliability. As high the reliability, larger will be the plant production. The main ways to improve the reliability of compression system are the use of multiple compression trains in parallel, in a 2x50% or 3x50% configuration, with one in stand-by. Such configurations are possible and have some advantages and disadvantages, but the main side effect is the increase of the cost. This is the offshore common practice, but that does not always significantly improve the plant availability, depending of the previous process system. A series arrangement and a critical evaluation of the overall system in some cases can provide a cheaper system with equal or better performance. This paper shows a case study of the procedure to evaluate a compression system design to improve the reliability but without extreme cost increase, balancing the number of equipment, the series or parallel arrangement, and the driver selection. Two cases studies will be
Accelerated life testing and reliability of high K multilayer ceramic capacitors
Minford, W. J.
1981-01-01
The reliability of one lot of high K multilayer ceramic capacitors was evaluated using accelerated life testing. The degradation in insulation resistance was characterized as a function of voltage and temperature. The times to failure at a voltage-temperature stress conformed to a lognormal distribution with a standard deviation approximately 0.5.
Standard semiconductor packaging for high-reliability low-cost MEMS applications
Harney, Kieran P.
2005-01-01
Microelectronic packaging technology has evolved over the years in response to the needs of IC technology. The fundamental purpose of the package is to provide protection for the silicon chip and to provide electrical connection to the circuit board. Major change has been witnessed in packaging and today wafer level packaging technology has further revolutionized the industry. MEMS (Micro Electro Mechanical Systems) technology has created new challenges for packaging that do not exist in standard ICs. However, the fundamental objective of MEMS packaging is the same as traditional ICs, the low cost and reliable presentation of the MEMS chip to the next level interconnect. Inertial MEMS is one of the best examples of the successful commercialization of MEMS technology. The adoption of MEMS accelerometers for automotive airbag applications has created a high volume market that demands the highest reliability at low cost. The suppliers to these markets have responded by exploiting standard semiconductor packaging infrastructures. However, there are special packaging needs for MEMS that cannot be ignored. New applications for inertial MEMS devices are emerging in the consumer space that adds the imperative of small size to the need for reliability and low cost. These trends are not unique to MEMS accelerometers. For any MEMS technology to be successful the packaging must provide the basic reliability and interconnection functions, adding the least possible cost to the product. This paper will discuss the evolution of MEMS packaging in the accelerometer industry and identify the main issues that needed to be addressed to enable the successful commercialization of the technology in the automotive and consumer markets.
Improved Yield, Performance and Reliability of High-Actuator-Count Deformable Mirrors, Phase I
National Aeronautics and Space Administration — The project team will conduct processing and design research aimed at improving yield, performance, and reliability of high-actuator-count micro-electro-mechanical...
Extented second moment algebra as an efficient tool in structural reliability
International Nuclear Information System (INIS)
Ditlevsen, O.
1982-01-01
During the seventies, second moment structural reliability analysis was extensively discussed with respect to philosophy and method. One recent clarification into a consistent formalism is represented by the extended second moment reliability theory with the generalized reliability index as its measure of safety. Its methods of formal failure probability calculations are useful independent of the opinion that one may adopt about the philosophy of the second moment reliability formalism. After an introduction of the historical development of the philosphy the paper gives a short introductory review of the extended second moment structural reliability theory. (orig.)
Predicting Cost/Reliability/Maintainability of Advanced General Aviation Avionics Equipment
Davis, M. R.; Kamins, M.; Mooz, W. E.
1978-01-01
A methodology is provided for assisting NASA in estimating the cost, reliability, and maintenance (CRM) requirements for general avionics equipment operating in the 1980's. Practical problems of predicting these factors are examined. The usefulness and short comings of different approaches for modeling coast and reliability estimates are discussed together with special problems caused by the lack of historical data on the cost of maintaining general aviation avionics. Suggestions are offered on how NASA might proceed in assessing cost reliability CRM implications in the absence of reliable generalized predictive models.
High-Specificity Targeted Functional Profiling in Microbial Communities with ShortBRED.
Directory of Open Access Journals (Sweden)
James Kaminski
2015-12-01
Full Text Available Profiling microbial community function from metagenomic sequencing data remains a computationally challenging problem. Mapping millions of DNA reads from such samples to reference protein databases requires long run-times, and short read lengths can result in spurious hits to unrelated proteins (loss of specificity. We developed ShortBRED (Short, Better Representative Extract Dataset to address these challenges, facilitating fast, accurate functional profiling of metagenomic samples. ShortBRED consists of two components: (i a method that reduces reference proteins of interest to short, highly representative amino acid sequences ("markers" and (ii a search step that maps reads to these markers to quantify the relative abundance of their associated proteins. After evaluating ShortBRED on synthetic data, we applied it to profile antibiotic resistance protein families in the gut microbiomes of individuals from the United States, China, Malawi, and Venezuela. Our results support antibiotic resistance as a core function in the human gut microbiome, with tetracycline-resistant ribosomal protection proteins and Class A beta-lactamases being the most widely distributed resistance mechanisms worldwide. ShortBRED markers are applicable to other homology-based search tasks, which we demonstrate here by identifying phylogenetic signatures of antibiotic resistance across more than 3,000 microbial isolate genomes. ShortBRED can be applied to profile a wide variety of protein families of interest; the software, source code, and documentation are available for download at http://huttenhower.sph.harvard.edu/shortbred.
Institute of Scientific and Technical Information of China (English)
Ping TAN; Wei-ting HE; Jia LIN; Hong-ming ZHAO; Jian CHU
2011-01-01
With the development of high-speed railways in China,more than 2000 high-speed trains will be put into use.Safety and efficiency of railway transportation is increasingly important.We have designed a high availability quadruple vital computer (HAQVC) system based on the analysis of the architecture of the traditional double 2-out-of-2 system and 2-out-of-3 system.The HAQVC system is a system with high availability and safety,with prominent characteristics such as fire-new internal architecture,high efficiency,reliable data interaction mechanism,and operation state change mechanism.The hardware of the vital CPU is based on ARM7 with the real-time embedded safe operation system (ES-OS).The Markov modeling method is designed to evaluate the reliability,availability,maintainability,and safety (RAMS) of the system.In this paper,we demonstrate that the HAQVC system is more reliable than the all voting triple modular redundancy (AVTMR) system and double 2-out-of-2 system.Thus,the design can be used for a specific application system,such as an airplane or high-speed railway system.
Design reliability engineering
International Nuclear Information System (INIS)
Buden, D.; Hunt, R.N.M.
1989-01-01
Improved design techniques are needed to achieve high reliability at minimum cost. This is especially true of space systems where lifetimes of many years without maintenance are needed and severe mass limitations exist. Reliability must be designed into these systems from the start. Techniques are now being explored to structure a formal design process that will be more complete and less expensive. The intent is to integrate the best features of design, reliability analysis, and expert systems to design highly reliable systems to meet stressing needs. Taken into account are the large uncertainties that exist in materials, design models, and fabrication techniques. Expert systems are a convenient method to integrate into the design process a complete definition of all elements that should be considered and an opportunity to integrate the design process with reliability, safety, test engineering, maintenance and operator training. 1 fig
Spectrum-energy Correlations in GRBs: Update, Reliability, and the Long/Short Dichotomy
Zhang, Z. B.; Zhang, C. T.; Zhao, Y. X.; Luo, J. J.; Jiang, L. Y.; Wang, X. L.; Han, X. L.; Terheide, R. K.
2018-05-01
Spectrum-energy correlations of peak energy with total prompt γ-ray emission energies, namely {E}p,i-{E}{iso}, {E}p,i-{E}γ , and {E}p,i-{L}p, had been studied for long gamma-ray bursts (GRBs) previously by many authors. These energy correlations were proposed to measure the universe and classify GRBs as useful probes. However, most of these relations were built by non-Swift bursts. The spectrum-energy correlations of short bursts have not been systematically established yet; in particular, how the newly found GRB170817A matches these energy relations is unknown to date. We will first refresh the three spectrum-energy relations of Swift/BAT and Fermi/GBM long bursts and build the corresponding relations of short bursts. Then, we confirm whether they are commonly available as a discriminator of short and long GRBs. Some potential violators to these relations will be investigated. Combining with the plane of peak energy versus fluence, we select 31 short and 252 long GRBs with well-measured peak energy and redshift to study the issue of GRB classifications connected with the above energy relations statistically. We find that the three energy relations do exist in our new GRB samples and they are marginally consistent with some previous results. We report for the first time that short GRBs hold the three corresponding energy relations having the consistent power-law indices with long GRBs. It is found that these energy relations can be adopted to discriminate GRBs successfully if they are put in the peak energy versus fluence plane. Excitingly, we point out that GRB090510 matches the energy relations of {E}p,i-{E}{iso} and {E}p,i-{L}p, but violates the {E}p,i-{E}γ relation. More excitingly, we find that GRB170817A is an outlier to all the three energy correlations.
High frequency study of a short niobium/lead alloy line
International Nuclear Information System (INIS)
Mazuer, J.; Gilchrist, J.
1974-01-01
The resonant Q-factors of coaxial lines 1.42 m in length, consisting of fine niobium wires in superconducting tubes, have been studied. The lines are either open-circuited at each end or else short-circuited at each end. In either case the fundamental resonance and odd harmonics up to the ninth were observed. Various surface treatments of the wire made no appreciable difference to the Q value of the open-circuited lines. The short-circuited lines had much lower Q values due to imperfect short-circuiting contacts, and were used mainly to study the effect of a superposed direct current. This was appreciable even when the current was much smaller than the current that the wire would support without resistive transition. The additional high-frequency loss caused by the current was attributed to flux penetration. (author)
High voltage short plus generation based on avalanche circuit
International Nuclear Information System (INIS)
Hu Yuanfeng; Yu Xiaoqi
2006-01-01
Simulate the avalanche circuit in series with PSPICE module, design the high voltage short plus generation circuit by avalanche transistor in series for the sweep deflection circuit of streak camera. The output voltage ranges 1.2 KV into 50 ohm load. The rise time of the circuit is less than 3 ns. (authors)
Mechanical reliability of bulk high Tc superconductors
International Nuclear Information System (INIS)
Freiman, S.W.
1990-01-01
Most prospective applications for high T c superconductors in bulk form, e.g. magnets, motors, will require appreciable mechanical strength. Work at NIST [National Institute of Standards and Technology] has begun to address issues related to mechanical reliability. For example, recent studies on Ba-Y-Cu-O have shown that the intrinsic crack growth resistance, K IC , of crystals of this material is even smaller than was first reported, less than that of window glass, and is sensitive to moisture. Processing conditions, particularly sintering and annealing atmosphere, have been shown to have a major influence on microstructure and internal stresses in the material. Large internal stresses result from the tetragonal to orthorhombic phase transformation as well as the thermal expansion anisotropy in the grains of the ceramic. Because stress relief is absent, microcracks form which have a profound influence on strength
Temple, L Parker
2012-01-01
Implosion is a focused study of the history and uses of high-reliability, solid-state electronics, military standards, and space systems that support our national security and defense. This book is unique in combining the interdependent evolution of and interrelationships among military standards, solid-state electronics, and very high-reliability space systems. Starting with a brief description of the physics that enabled the development of the first transistor, Implosion covers the need for standardizing military electronics, which began during World War II and continu
Reliability and validity of academic motivation scale for sports high school students’
Directory of Open Access Journals (Sweden)
Haslofça Fehime
2016-01-01
Full Text Available This study was designed to test validity and reliability of Academic Motivation Scale (AMS for sports high school students. The research conducted with 357 volunteered girls (n=117 and boys (n=240. Confirmatory factor analysis showed that Chi square (χ2, degrees of freedom (df and χ2/df ratio were 1102.90, 341 and 3.234, respectively. Goodness of Fit Index, Comparative Fit Index, Non-normed Fit Index and Incremental Fit Index were between 0.92-0.95. Additionally, Adjusted Goodness of Fit Index, An Average Errors Square Root and Root Mean Square Error of Approximation were 0.88, 0.070 and 0.079, respectively. Subscale reliability coefficients were between 0.77 and 0.86. Test-retest correlations of AMS were found between 0.79 and 0.91. Results showed that scale was suitable for determination of sports high school students’ academicals motivation levels.
Night-to-night arousal variability and interscorer reliability of arousal measurements.
Loredo, J S; Clausen, J L; Ancoli-Israel, S; Dimsdale, J E
1999-11-01
Measurement of arousals from sleep is clinically important, however, their definition is not well standardized, and little data exist on reliability. The purpose of this study is to determine factors that affect arousal scoring reliability and night-to-night arousal variability. The night-to-night arousal variability and interscorer reliability was assessed in 20 subjects with and without obstructive sleep apnea undergoing attended polysomnography during two consecutive nights. Five definitions of arousal were studied, assessing duration of electroencephalographic (EEG) frequency changes, increases in electromyographic (EMG) activity and leg movement, association with respiratory events, as well as the American Sleep Disorders Association (ASDA) definition of arousals. NA. NA. NA. Interscorer reliability varied with the definition of arousal and ranged from an Intraclass correlation (ICC) of 0.19 to 0.92. Arousals that included increases in EMG activity or leg movement had the greatest reliability, especially when associated with respiratory events (ICC 0.76 to 0.92). The ASDA arousal definition had high interscorer reliability (ICC 0.84). Reliability was lowest for arousals consisting of EEG changes lasting <3 seconds (ICC 0.19 to 0.37). The within subjects night-to-night arousal variability was low for all arousal definitions In a heterogeneous population, interscorer arousal reliability is enhanced by increases in EMG activity, leg movements, and respiratory events and decreased by short duration EEG arousals. The arousal index night-to-night variability was low for all definitions.
Patient safety in anesthesia: learning from the culture of high-reliability organizations.
Wright, Suzanne M
2015-03-01
There has been an increased awareness of and interest in patient safety and improved outcomes, as well as a growing body of evidence substantiating medical error as a leading cause of death and injury in the United States. According to The Joint Commission, US hospitals demonstrate improvements in health care quality and patient safety. Although this progress is encouraging, much room for improvement remains. High-reliability organizations, industries that deliver reliable performances in the face of complex working environments, can serve as models of safety for our health care system until plausible explanations for patient harm are better understood. Copyright © 2015 Elsevier Inc. All rights reserved.
Ultra Reliable Closed Loop Life Support for Long Space Missions
Jones, Harry W.; Ewert, Michael K.
2010-01-01
Spacecraft human life support systems can achieve ultra reliability by providing sufficient spares to replace all failed components. The additional mass of spares for ultra reliability is approximately equal to the original system mass, provided that the original system reliability is not too low. Acceptable reliability can be achieved for the Space Shuttle and Space Station by preventive maintenance and by replacing failed units. However, on-demand maintenance and repair requires a logistics supply chain in place to provide the needed spares. In contrast, a Mars or other long space mission must take along all the needed spares, since resupply is not possible. Long missions must achieve ultra reliability, a very low failure rate per hour, since they will take years rather than weeks and cannot be cut short if a failure occurs. Also, distant missions have a much higher mass launch cost per kilogram than near-Earth missions. Achieving ultra reliable spacecraft life support systems with acceptable mass will require a well-planned and extensive development effort. Analysis must determine the reliability requirement and allocate it to subsystems and components. Ultra reliability requires reducing the intrinsic failure causes, providing spares to replace failed components and having "graceful" failure modes. Technologies, components, and materials must be selected and designed for high reliability. Long duration testing is needed to confirm very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The system must be designed, developed, integrated, and tested with system reliability in mind. Maintenance and reparability of failed units must not add to the probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass should start soon since it must be a long term effort.
ISRNA: an integrative online toolkit for short reads from high-throughput sequencing data.
Luo, Guan-Zheng; Yang, Wei; Ma, Ying-Ke; Wang, Xiu-Jie
2014-02-01
Integrative Short Reads NAvigator (ISRNA) is an online toolkit for analyzing high-throughput small RNA sequencing data. Besides the high-speed genome mapping function, ISRNA provides statistics for genomic location, length distribution and nucleotide composition bias analysis of sequence reads. Number of reads mapped to known microRNAs and other classes of short non-coding RNAs, coverage of short reads on genes, expression abundance of sequence reads as well as some other analysis functions are also supported. The versatile search functions enable users to select sequence reads according to their sub-sequences, expression abundance, genomic location, relationship to genes, etc. A specialized genome browser is integrated to visualize the genomic distribution of short reads. ISRNA also supports management and comparison among multiple datasets. ISRNA is implemented in Java/C++/Perl/MySQL and can be freely accessed at http://omicslab.genetics.ac.cn/ISRNA/.
650-nm-band high-power and highly reliable laser diodes with a window-mirror structure
Shima, Akihiro; Hironaka, Misao; Ono, Ken-ichi; Takemi, Masayoshi; Sakamoto, Yoshifumi; Kunitsugu, Yasuhiro; Yamashita, Koji
1998-05-01
An active layer structure with 658 nm-emission at 25 degrees Celsius has been optimized in order to reduce the operating current of the laser diodes (LD) under high temperature condition. For improvement of the maximum output power and the reliability limited by mirror degradation, we have applied a zinc-diffused-type window-mirror structure which prevents the optical absorption at the mirror facet. As a result, the CW output power of 50 mW is obtained even at 80 degrees Celsius for a 650 micrometer-long window-mirror LD. In addition, the maximum light output power over 150 mW at 25 degrees Celsius has been realized without any optical mirror damage. In the aging tests, the LDs have been operating for over 2,500 - 5,000 hours under the CW condition of 30 - 50 mW at 60 degrees Celsius. The window-mirror structure also enables reliable 60 degree Celsius, 30 mW, CW operation of the LDs with 651 nm- emission at 25 degrees Celsius. Moreover, the maximum output power of around 100 mW even at 80 degrees Celsius and reliable 2,000-hour operation at 60 degrees Celsius, 70 mW have been realized for the first time by 659 nm LDs with a long cavity length of 900 micrometers.
Energy Technology Data Exchange (ETDEWEB)
Bouhouras, Aggelos S.; Labridis, Dimitris P.; Bakirtzis, Anastasios G. [Power Systems Laboratory, Aristotle University of Thessaloniki, Dept. of Electrical and Computer Engineering, 54124 Thessaloniki (Greece)
2010-06-15
A major challenge for the power utilities today is to ensure a high level of reliability of supply to customers. Two main factors determine the feasibility of a project that improves the reliability of supply: the project cost (investment and operational) and the benefits that result from the implementation of the project. This paper examines the implementation of an Artificial Intelligence System in an urban distribution network, capable to locate and isolate short circuit faults in the feeder, thus accomplishing immediate restoration of electric supply to the customers. The paper describes the benefits of the project, which are supply reliability improvement and distribution network loss reduction through network reconfigurations. By comparison of the project benefits and costs the economic feasibility of such a project for an underground distribution feeder in Greece is demonstrated. (author)
Oubaid, V; Anheuser, P
2014-05-01
Employees represent an important safety factor in high-reliability organizations. The combination of clear organizational structures, a nonpunitive safety culture, and psychological personnel selection guarantee a high level of safety. The cockpit personnel selection process of a major German airline is presented in order to demonstrate a possible transferability into medicine and urology.
Research with high-power short-wavelength lasers
International Nuclear Information System (INIS)
Holzrichter, J.F.; Campbell, E.M.; Lindl, J.D.; Storm, E.
1985-01-01
Three important high-temperature, high-density experiments were conducted recently using the 10-TW, short-wavelength Novette laser system at the Lawrence Livermore National Laboratory. These experiments demonstrated successful solutions to problems that arose during previous experiments with long wavelength lasers (lambda greater than or equal to 1μm) in which inertial confinement fusion (ICF), x-ray laser, and other high-temperature physics concepts were being tested. The demonstrations were: (1) large-scale plasmas (typical dimensions of up to 1000 laser wavelengths) were produced in which potentially deleterious laser-plasma instabilities were collisionally damped. (2) Deuterium-tritium fuel was imploded to a density of 20 g/cm 3 and a pressure of 10 10 atm. (3) A 700-fold amplification of soft x rays by stimulated emission at 206 and 209 A (62 eV) from Se +24 ions was observed in a laser-generated plasma. Isoelectronic scaling to 155 A (87 eV) in Y +29 was also demonstrated
Developing Ultra Reliable Life Support for the Moon and Mars
Jones, Harry W.
2009-01-01
Recycling life support systems can achieve ultra reliability by using spares to replace failed components. The added mass for spares is approximately equal to the original system mass, provided the original system reliability is not very low. Acceptable reliability can be achieved for the space shuttle and space station by preventive maintenance and by replacing failed units, However, this maintenance and repair depends on a logistics supply chain that provides the needed spares. The Mars mission must take all the needed spares at launch. The Mars mission also must achieve ultra reliability, a very low failure rate per hour, since it requires years rather than weeks and cannot be cut short if a failure occurs. Also, the Mars mission has a much higher mass launch cost per kilogram than shuttle or station. Achieving ultra reliable space life support with acceptable mass will require a well-planned and extensive development effort. Analysis must define the reliability requirement and allocate it to subsystems and components. Technologies, components, and materials must be designed and selected for high reliability. Extensive testing is needed to ascertain very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The systems must be designed, produced, integrated, and tested without impairing system reliability. Maintenance and failed unit replacement should not introduce any additional probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass must start soon if it is to produce timely results for the moon and Mars.
Cost-effective solutions to maintaining smart grid reliability
Qin, Qiu
As the aging power systems are increasingly working closer to the capacity and thermal limits, maintaining an sufficient reliability has been of great concern to the government agency, utility companies and users. This dissertation focuses on improving the reliability of transmission and distribution systems. Based on the wide area measurements, multiple model algorithms are developed to diagnose transmission line three-phase short to ground faults in the presence of protection misoperations. The multiple model algorithms utilize the electric network dynamics to provide prompt and reliable diagnosis outcomes. Computational complexity of the diagnosis algorithm is reduced by using a two-step heuristic. The multiple model algorithm is incorporated into a hybrid simulation framework, which consist of both continuous state simulation and discrete event simulation, to study the operation of transmission systems. With hybrid simulation, line switching strategy for enhancing the tolerance to protection misoperations is studied based on the concept of security index, which involves the faulted mode probability and stability coverage. Local measurements are used to track the generator state and faulty mode probabilities are calculated in the multiple model algorithms. FACTS devices are considered as controllers for the transmission system. The placement of FACTS devices into power systems is investigated with a criterion of maintaining a prescribed level of control reconfigurability. Control reconfigurability measures the small signal combined controllability and observability of a power system with an additional requirement on fault tolerance. For the distribution systems, a hierarchical framework, including a high level recloser allocation scheme and a low level recloser placement scheme, is presented. The impacts of recloser placement on the reliability indices is analyzed. Evaluation of reliability indices in the placement process is carried out via discrete event
High Energy, Short Pulse Fiber Injection Lasers at Lawrence Livermore National Laboratory
Energy Technology Data Exchange (ETDEWEB)
Dawson, J W; Messerly, M J; Phan, H H; Crane, J K; Beach, R J; Siders, C W; Barty, C J
2008-09-10
A short pulse fiber injection laser for the Advanced Radiographic Capability (ARC) on the National Ignition Facility (NIF) has been developed at Lawrence Livermore National Laboratory (LLNL). This system produces 100 {micro}J pulses with 5 nm of bandwidth centered at 1053 nm. The pulses are stretched to 2.5 ns and have been recompressed to sub-ps pulse widths. A key feature of the system is that the pre-pulse power contrast ratio exceeds 80 dB. The system can also precisely adjust the final recompressed pulse width and timing and has been designed for reliable, hands free operation. The key challenges in constructing this system were control of the signal to noise ratio, dispersion management and managing the impact of self phase modulation on the chirped pulse.
Generating high-power short terahertz electromagnetic pulses with a multifoil radiator.
Vinokurov, Nikolay A; Jeong, Young Uk
2013-02-08
We describe a multifoil cone radiator capable of generating high-field short terahertz pulses using short electron bunches. Round flat conducting foil plates with successively decreasing radii are stacked, forming a truncated cone with the z axis. The gaps between the foil plates are equal and filled with some dielectric (or vacuum). A short relativistic electron bunch propagates along the z axis. At sufficiently high particle energy, the energy losses and multiple scattering do not change the bunch shape significantly. When passing by each gap between the foil plates, the electron bunch emits some energy into the gap. Then, the radiation pulses propagate radially outward. For transverse electromagnetic waves with a longitudinal (along the z axis) electric field and an azimuthal magnetic field, there is no dispersion in these radial lines; therefore, the radiation pulses conserve their shapes (time dependence). At the outer surface of the cone, we have synchronous circular radiators. Their radiation field forms a conical wave. Ultrashort terahertz pulses with gigawatt-level peak power can be generated with this device.
Goode, Adam P; Ni, Pengshend; Jette, Alan; Fitzgerald, G Kelley
2018-04-19
Pragmatic studies have gained popularity, thus emphasizing the need for patient-reported outcomes (PRO) to be integrated into electronic health records. This study describes the development of a customized short form from the Boston University Osteoarthritis Functional Assessment PRO (BU-OA-PRO) for a specific pragmatic clinical trial. A Functional Pain Short Form was created from an existing item bank of deidentified data in the BU-OA-PRO. Item response theory (IRT) methods were used to select items. Reliability was measured with the Cronbach alpha, then with IRT simulation methods. To examine validity, ceiling and floor effects, correlations between the short-form scores and scores from the BU-OA-PRO and the Western Ontario McMasters University Osteoarthritis Index (WOMAC) Pain and Difficulty subscales, and the area under the curve (AUC) were calculated. A minimum detectable change at 90% confidence (MDC90) was calculated based on a calibration sample. The BU-OA PRO was reduced from 126 items to 10 items to create the BU-OA Functional Pain Short Form (BU-OA-FPS). The Cronbach alpha indicated high internal consistency (0.91), and reliability distribution estimates were 0.96 (uniform) and 0.92 (normal). Low ceiling effects (4.57%), and floor effects (0%) were found. Moderate-to-high correlations between the BU-OA PRO and BU-OA-FPS were found with WOMAC Pain (BU-OA-FPS = 0.67; BU-OA-PRO = 0.64) and Difficulty (BU-OA-FPS = 0.73; BU-OA-PRO = 0.69) subscales. The correlation between the BU-OA-PRO and BU-OA-FPS was 0.94. The AUC ranged from 0.80 to 0.88. The MDC90 was approximately 6 standardized points. The BU-OA-FPS provides reliable and valid measurement of functional pain. Pragmatic studies may consider the BU-OA-FPS for use in electronic health records to capture outcomes.
Optimization of a PCRAM Chip for high-speed read and highly reliable reset operations
Li, Xiaoyun; Chen, Houpeng; Li, Xi; Wang, Qian; Fan, Xi; Hu, Jiajun; Lei, Yu; Zhang, Qi; Tian, Zhen; Song, Zhitang
2016-10-01
The widely used traditional Flash memory suffers from its performance limits such as its serious crosstalk problems, and increasing complexity of floating gate scaling. Phase change random access memory (PCRAM) becomes one of the most potential nonvolatile memories among the new memory techniques. In this paper, a 1M-bit PCRAM chip is designed based on the SMIC 40nm CMOS technology. Focusing on the read and write performance, two new circuits with high-speed read operation and highly reliable reset operation are proposed. The high-speed read circuit effectively reduces the reading time from 74ns to 40ns. The double-mode reset circuit improves the chip yield. This 1M-bit PCRAM chip has been simulated on cadence. After layout design is completed, the chip will be taped out for post-test.
Escobar, Antonio; Trujillo-Martín, Maria del Mar; Rueda, Antonio; Pérez-Ruiz, Elisabeth; Avis, Nancy E; Bilbao, Amaia
2015-11-16
The aim of this study was to validate the Quality of Life in Adult Cancer Survivors (QLACS) in short-term Spanish cancer survivor's patients. Patients with breast, colorectal or prostate cancer that had finished their initial cancer treatment 3 years before the beginning of this study completed QLACS, WHOQOL, Short Form-36, Hospital Anxiety and Depression Scale, EORTC-QLQ-BR23 and EQ-5D. Cultural adaptation was made based on established guidelines. Reliability was evaluated using internal consistency and test-retest. Convergent validity was studied by mean of Pearson's correlation coefficient. Structural validity was determined by a second-order confirmatory factor analysis (CFA) and Rasch analysis was used to assess the unidimensionality of the Generic and Cancer-specific scales. Cronbach's alpha were above 0.7 in all domains and summary scales. Test-retest coefficients were 0.88 for Generic and 0.82 for Cancer-specific summary scales. QLACS generic summary scale was correlated with other generic criterion measures, SF-36 MCS (r = - 0.74) and EQ-VAS (r = - 0.63). QLACS cancer-specific scale had lower values with the same constructs. CFA provided satisfactory fit indices in all cases. The RMSEA value was 0.061 and CFI and TLI values were 0.929 and 0.925, respectively. All factor loadings were higher than 0.40 and statistically significant (P validity and reliability of QLACS questionnaire to be used in short-term cancer survivors.
Reliability Evaluation on Creep Life Prediction of Alloy 617 for a Very High Temperature Reactor
International Nuclear Information System (INIS)
Kim, Woo-Gon; Hong, Sung-Deok; Kim, Yong-Wan; Park, Jae-Young; Kim, Seon-Jin
2012-01-01
This paper evaluates the reliability of creep rupture life under service conditions of Alloy 617, which is considered as one of the candidate materials for use in a very high temperature reactor (VHTR) system. A Z-parameter, which represents the deviation of creep rupture data from the master curve, was used for the reliability analysis of the creep rupture data of Alloy 617. A Service-condition Creep Rupture Interference (SCRI) model, which can consider both the scattering of the creep rupture data and the fluctuations of temperature and stress under any service conditions, was also used for evaluating the reliability of creep rupture life. The statistical analysis showed that the scattering of creep rupture data based on Z-parameter was supported by normal distribution. The values of reliability decreased rapidly with increasing amplitudes of temperature and stress fluctuations. The results established that the reliability decreased with an increasing service time.
DEFF Research Database (Denmark)
Busca, Christian; Teodorescu, Remus; Blaabjerg, Frede
2011-01-01
Reliability is becoming more and more important as the size and number of installed Wind Turbines (WTs) increases. Very high reliability is especially important for offshore WTs because the maintenance and repair of such WTs in case of failures can be very expensive. WT manufacturers need...
Davenport, Todd E; Stevens, Staci R; Baroni, Katie; Van Ness, J Mark; Snell, Christopher R
2011-01-01
To determine the validity and reliability of Short Form 36 Version 2 (SF36v2) in sub-groups of individuals with fatigue. Thirty subjects participated in this study, including n = 16 subjects who met case definition criteria for chronic fatigue syndrome (CFS) and n = 14 non-disabled sedentary matched control subjects. SF36v2 and Multidimensional Fatigue Inventory (MFI-20) were administered before two maximal cardiopulmonary exercise tests (CPETs) administered 24 h apart and an open-ended recovery questionnaire was administered 7 days after CPET challenge. The main outcome measures were self-reported time to recover to pre-challenge functional and symptom status, frequency of post-exertional symptoms and SF36v2 sub-scale scores. Individuals with CFS demonstrated significantly lower SF36v2 and MFI-20 sub-scale scores prior to CPET. Between-group differences remained significant post-CPET, however, there were no significant group by test interaction effects. Subjects with CFS reported significantly more total symptoms (p validity to identify subjects who recovered from CPET challenge within 1 day and 7 days (p reliability and validity for clinical and research applications. Adequacy of sensitivity to change of SF36v2 as a result of a fatiguing stressor should be the subject of additional study.
Reliability and Characterization of High Voltage Power Capacitors
2014-03-01
in a Faraday cage to minimize external noise. In addition, electron microscopy could also be performed to identify the change in trap concentration...military bases in the United States. Energy product reliability affects the sustainability and cost- effectiveness of these systems, which must be tested...Energy product reliability affects the sustainability and cost- effectiveness of these systems, which must be tested by outside entities to ensure
Reliability of concussion history in former professional football players.
Kerr, Zachary Y; Marshall, Stephen W; Guskiewicz, Kevin M
2012-03-01
The reliability of athletes to recall and self-report a concussion history has never been quantified. This study examined the reliability of the self-report concussion history measure and explored determinants of recall in the number of self-reported concussions in a group of retired professional football players. In 2001, a short questionnaire was administered to a cohort of former professional football players to ascertain the number of self-reported concussions they sustained during their professional playing careers. In 2010, the same instrument was readministered to a subset (n = 899) of the original cohort to assess reliability. Overall reliability was moderate (weighted Cohen κ = 0.48). The majority (62.1%) reported the same number of concussions in both administrations (2001 and 2010); 31.4% reported more concussions in the second administration. Compared with the "same number reported" group, the "greater number reported" group had more deficits in the second administration in their Short Form 36 physical health (composite score combining physical functioning, role physical, bodily pain, general health) and mental health (e.g., composite score combining vitality, social functioning, role emotional) scales. The self-reported concussion history had moderate reliability in former professional football players, on the basis of two administrations of the same instrument, 9 yr apart. However, changes in health status may be differentially associated with recall of concussions.
Wear, L L; Pinkert, J R
1993-11-01
In this article, we looked at some decisions that apply to the design of reliable computer systems. We began with a discussion of several terms such as testability, then described some systems that call for highly reliable hardware and software. The article concluded with a discussion of methods that can be used to achieve higher reliability in computer systems. Reliability and fault tolerance in computers probably will continue to grow in importance. As more and more systems are computerized, people will want assurances about the reliability of these systems, and their ability to work properly even when sub-systems fail.
Directory of Open Access Journals (Sweden)
Maryam Sepehri
2017-06-01
Full Text Available Introduction: A short screening tool for high-risk individuals with personality disorder (PD is useful both for clinicians and researchers. The aim of this study was to assess the validity and reliability of the Farsi version of the Standardized Assessment of Personality-Abbreviated Scale (SAPAS. Methods: The original English version of the SAPAS questionnaire was translated into Farsi, and then, translated back into English by two professionals. A survey was then conducted using the questionnaire on 150 clients of primary health care centers in Tabriz, Iran. A total of 235 medical students were also studied for the reliability assessment of the questionnaire. The SAPAS was compared to the short form of Minnesota Multiphasic Personality Inventory (MMPI. The data analysis was performed using receiver operating characteristic (ROC curve technique, operating characteristic for diagnostic efficacy, Cronbach's alpha, and test-retest for reliability evaluation. Results: We found an area under the curve (AUC of 0.566 [95% confidence intervals (CI: 0.455-0.677]; sensitivity of 0.89 and specificity of 0.26 at the cut-off score of 2 and higher. The total Cronbach's alpha coefficient was 0.38 and Cohen's kappa ranged between 0.5 and 0.8. Conclusion: The current study showed that the Farsi version of the SAPAS was relatively less efficient, in term of validity and reliability, in the screening of PD in the population.
Validation of the Short Form of the Academic Procrastination Scale.
Yockey, Ronald D
2016-02-01
The factor structure, internal consistency reliability, and convergent validity of the five-item Academic Procrastination Scale-Short Form was investigated on an ethnically diverse sample of college students. The results provided support for the Academic Procrastination Scale-Short Form as a unidimensional measure of academic procrastination, which possessed good internal consistency reliability in this sample of 282 students. The scale also demonstrated good convergent validity, with moderate to large correlations with both the Procrastination Assessment Scale-Students and the Tuckman Procrastination Scale. Implications of the results are discussed and recommendations for future work provided.
Short-term versus long-term contracting for uranium enrichment services
International Nuclear Information System (INIS)
Rudy, G.P.
1990-01-01
The US Department of Energy (US DOE) is the world's largest and most experienced supplier of uranium enrichment services. Through the late 1970s and early 1980s, emerging market forces transformed what was once a monopoly into a highly competitive industry. In the early 1980's the DOE lost market share. But as we enter the 1990s, new market forces have emerged. The US DOE believes a responsible balance between long-term and short-term contracting will be the key to success and the key to assuring the long-term health and reliability of the nuclear fuel industry. The US DOE intends to be in this nuclear business for a long time and will continue to offer reliable and responsive services second to none
Vietnamese validation of the short version of Internet Addiction Test
Directory of Open Access Journals (Sweden)
Bach Xuan Tran
2017-12-01
Full Text Available Background and aims: The main goal of the present study was to examine the psychometric properties of a Vietnamese version of the short-version of Internet Addiction Test (s-IAT and to assess the relationship between s-IAT scores and demographics, health related qualify of life and perceived stress scores in young Vietnamese. Methods: The Vietnamese version of s-IAT was administered to a sample of 589 participants. Exploratory factor and reliability analyses were performed. Regression analysis was used to identify the associated factors. Results: The two-factor model of Vietnamese version of s-IAT demonstrated good psychometric properties. The internal consistency of Factor 1 (loss of control/time management was high (Cronbach's alpha=0.82 and Factor 2 (craving/social problems was satisfactory (Cronbach's alpha=0.75. Findings indicated that 20.9% youths were addicted to the Internet. Regression analysis revealed significant associations between Internet addiction and having problems in self-care, lower quality of life and high perceived stress scores. Discussion and conclusions: The Vietnamese version of s-IAT is a valid and reliable instrument to assess IA in Vietnamese population. Due to the high prevalence of IA among Vietnamese youths, IA should be paid attention in future intervention programs. s-IAT can be a useful screening tool for IA to promptly inform and treat the IA among Vietnamese youths. Keywords: Factor analysis, Short-version, Internet Addiction Test, Psychometric properties, Vietnamese
Weighted integration of short-term memory and sensory signals in the oculomotor system.
Deravet, Nicolas; Blohm, Gunnar; de Xivry, Jean-Jacques Orban; Lefèvre, Philippe
2018-05-01
Oculomotor behaviors integrate sensory and prior information to overcome sensory-motor delays and noise. After much debate about this process, reliability-based integration has recently been proposed and several models of smooth pursuit now include recurrent Bayesian integration or Kalman filtering. However, there is a lack of behavioral evidence in humans supporting these theoretical predictions. Here, we independently manipulated the reliability of visual and prior information in a smooth pursuit task. Our results show that both smooth pursuit eye velocity and catch-up saccade amplitude were modulated by visual and prior information reliability. We interpret these findings as the continuous reliability-based integration of a short-term memory of target motion with visual information, which support modeling work. Furthermore, we suggest that saccadic and pursuit systems share this short-term memory. We propose that this short-term memory of target motion is quickly built and continuously updated, and constitutes a general building block present in all sensorimotor systems.
Short Circuits of a 10 MW High Temperature Superconducting Wind Turbine Generator
DEFF Research Database (Denmark)
Song, Xiaowei (Andy); Liu, Dong; Polinder, Henk
2016-01-01
Direct drive high temperature superconducting (HTS) wind turbine generators have been proposed to tackle challenges for ever increasing wind turbine ratings. Due to smaller reactances in HTS generators, higher fault currents and larger transient torques could occur if sudden short circuits happen...... at generator terminals. In this paper, a finite element model that couples magnetic fields and the generator’s equivalent circuits is developed to simulate short circuit faults. Afterwards, the model is used to study the transient performance of a 10 MW HTS wind turbine generator under four different short...... that the short circuits pose great challenges to the generator, and careful consideration should be given to protect the generator. The results presented in this paper would be beneficial to the design, operation and protection of an HTS wind turbine generator....
[Development of a Japanese version of a short form of the Profile of Emotional Competence].
Nozaki, Yuki; Koyasu, Masuo
2015-06-01
Emotional competence refers to individual differences in the ability to appropriately identity, understand, express, regulate, and utilize one's own emotions and those of others. This study developed a Japanese version of a short form of the Profile of Emotional Competence, a measure that allows the comprehensive assessment of intra- and interpersonal emotional competence with shorter items, and investigated its reliability and validity. In Study 1, we selected items for a short version and compared it with the full scale in terms of scores, internal consistency, and validity. In Study 2, we examined the short form's test-retest reliability. Results supported the original two-factor model and the measure had adequate reliability and validity. We discuss the construct validity and practical applicability of the short form of the Profile of Emotional Competence.
Wang, Ying; He, Zehui; Lei, Lifang; Lin, Dingkun; Li, Yajie; Wang, Gang; Zhai, Huimin; Xu, Jingli; Zhang, Guangqing; Lin, Meizhen
2015-07-07
The Short Musculoskeletal Function Assessment (SMFA) questionnaire is one of the most commonly used scales to evaluate functional status and quality of life (QOL) of patients with a broad range of musculoskeletal disorders. However, a Chinese version of the SMFA questionnaire for the psychometric properties of skeletal muscle injury patients in China is still lacking. The current study translated the SMFA into Chinese and assessed its reliability and validity among Chinese patients with skeletal muscle injury of the upper or lower extremities. The original SMFA was translated from English into Chinese and culturally adapted according to cross-cultural adaptation guidelines. A multicenter cross-sectional study was conducted, comprising 339 skeletal muscle injury patients (aged 20-75 years) from 4 hospitals. The SMFA, the health survey short form (SF-36) along with a region-specific questionnaire (including the disabilities of the arm, shoulder, and hand questionnaire (DASH), the hip disability and osteoarthritis outcome score (HOOS), the knee injury and osteoarthritis outcome score (KOOS), and the foot function index (FFI)) were completed according to the region of injury. Reliability was estimated from the internal consistency using Cronbach's α and validity was assessed via convergent validity, known-groups comparison, and construct validity. Cronbach's α coefficient was over 0.75 for two subscales and four categories of the SMFA, suggesting that the internal consistency reliability of the SMFA was satisfactory. Known-groups comparison showed that the dysfunction index and the bother index of the SMFA discriminated well between patients who differed in age, gender, injury location, and operation status rather than in subgroups based on the body mass index (BMI). The convergent validity of the SMFA was good, as moderate to excellent correlations were found between the subscales of the SMFA and the four subscales of SF-36 (physical function, role-physical, bodily
Design for High Performance, Low Power, and Reliable 3D Integrated Circuits
Lim, Sung Kyu
2013-01-01
This book describes the design of through-silicon-via (TSV) based three-dimensional integrated circuits. It includes details of numerous “manufacturing-ready” GDSII-level layouts of TSV-based 3D ICs, developed with tools covered in the book. Readers will benefit from the sign-off level analysis of timing, power, signal integrity, and thermo-mechanical reliability for 3D IC designs. Coverage also includes various design-for-manufacturability (DFM), design-for-reliability (DFR), and design-for-testability (DFT) techniques that are considered critical to the 3D IC design process. Describes design issues and solutions for high performance and low power 3D ICs, such as the pros/cons of regular and irregular placement of TSVs, Steiner routing, buffer insertion, low power 3D clock routing, power delivery network design and clock design for pre-bond testability. Discusses topics in design-for-electrical-reliability for 3D ICs, such as TSV-to-TSV coupling, current crowding at the wire-to-TSV junction and the e...
Why do short term workers have high mortality?
DEFF Research Database (Denmark)
Kolstad, Henrik; Olsen, Jørn
1999-01-01
or violence, the rate ratios for short term employment were 2.30 (95% Cl 1.74-3.06) and 1.86 (95% Cl 1.35-2.56), respectively. An unhealthy lifestyle may also be a determinant of short term employment. While it is possible in principle to adjust for lifestyle factors if proper data are collected, the health......Increased mortality is often reported among workers in short term employment. This may indicate either a health-related selection process or the presence of different lifestyle or social conditions among short term workers. The authors studied these two aspects of short term employment among 16...
Gearbox Reliability Collaborative Investigation of High-Speed-Shaft Bearing Loads
Energy Technology Data Exchange (ETDEWEB)
Keller, Jonathan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Guo, Yi [National Renewable Energy Lab. (NREL), Golden, CO (United States)
2016-06-01
The loads and contact stresses in the bearings of the high speed shaft section of the Gearbox Reliability Collaborative gearbox are examined in this paper. The loads were measured though strain gauges installed on the bearing outer races during dynamometer testing of the gearbox. Loads and stresses were also predicted with a simple analytical model and higher-fidelity commercial models. The experimental data compared favorably to each model, and bearing stresses were below thresholds for contact fatigue and axial cracking.
Influence of reliability of the relay protection to the whole reliability of electric power systems
International Nuclear Information System (INIS)
Stojanovski, Ljupcho I.
2001-01-01
The influence of the reliability of the elements of relay protection up today analyses of the reliability on electric power systems, very rare has been taken into consideration, in other words, in these analyses it is assumed that the reliability of the protection has value one. In this work an attempt is that through modelling of individual types of protection of the elements of high-voltage systems to make calculation to the influence of the reliability of the relay protection on the total reliability of the high-voltage systems.(Author)
Jenerette, Coretta; Dixon, Jane
2010-10-01
Ethnic and cultural norms influence an individual's assertiveness. In health care, assertiveness may play an important role in health outcomes, especially for predominantly minority populations, such as adults with sickle cell disease. Therefore, it is important to develop measures to accurately assess assertiveness. It is also important to reduce response burden of lengthy instruments while retaining instrument reliability and validity. The purpose of this article is to describe development of a shorter version of the Simple Rathus Assertiveness Schedule (SRAS). Data from a cross-sectional descriptive study of adults with sickle cell disease were used to construct a short form of the SRAS, guided by stepwise regression analysis. The 19-item Simple Rathus Assertiveness Scale-Short Form (SRAS-SF) had acceptable reliability (α = .81) and construct validity and was highly correlated with the SRAS (r = .98, p = .01). The SRAS-SF reduces response burden, while maintaining reliability and validity.
Reliable high-power diode lasers: thermo-mechanical fatigue aspects
Klumel, Genady; Gridish, Yaakov; Szafranek, Igor; Karni, Yoram
2006-02-01
High power water-cooled diode lasers are finding increasing demand in biomedical, cosmetic and industrial applications, where repetitive cw (continuous wave) and pulsed cw operation modes are required. When operating in such modes, the lasers experience numerous complete thermal cycles between "cold" heat sink temperature and the "hot" temperature typical of thermally equilibrated cw operation. It is clearly demonstrated that the main failure mechanism directly linked to repetitive cw operation is thermo-mechanical fatigue of the solder joints adjacent to the laser bars, especially when "soft" solders are used. Analyses of the bonding interfaces were carried out using scanning electron microscopy. It was observed that intermetallic compounds, formed already during the bonding process, lead to the solders fatigue both on the p- and n-side of the laser bar. Fatigue failure of solder joints in repetitive cw operation reduces useful lifetime of the stacks to hundreds hours, in comparison with more than 10,000 hours lifetime typically demonstrated in commonly adopted non-stop cw reliability testing programs. It is shown, that proper selection of package materials and solders, careful design of fatigue sensitive parts and burn-in screening in the hard pulse operation mode allow considerable increase of lifetime and reliability, without compromising the device efficiency, optical power density and compactness.
On the Consistency of Individual Classification Using Short Scales
Emons, Wilco H. M.; Sijtsma, Klaas; Meijer, Rob R.
2007-01-01
Short tests containing at most 15 items are used in clinical and health psychology, medicine, and psychiatry for making decisions about patients. Because short tests have large measurement error, the authors ask whether they are reliable enough for classifying patients into a treatment and a nontreatment group. For a given certainty level,…
DJ-1 is a reliable serum biomarker for discriminating high-risk endometrial cancer.
Di Cello, Annalisa; Di Sanzo, Maddalena; Perrone, Francesca Marta; Santamaria, Gianluca; Rania, Erika; Angotti, Elvira; Venturella, Roberta; Mancuso, Serafina; Zullo, Fulvio; Cuda, Giovanni; Costanzo, Francesco
2017-06-01
New reliable approaches to stratify patients with endometrial cancer into risk categories are highly needed. We have recently demonstrated that DJ-1 is overexpressed in endometrial cancer, showing significantly higher levels both in serum and tissue of patients with high-risk endometrial cancer compared with low-risk endometrial cancer. In this experimental study, we further extended our observation, evaluating the role of DJ-1 as an accurate serum biomarker for high-risk endometrial cancer. A total of 101 endometrial cancer patients and 44 healthy subjects were prospectively recruited. DJ-1 serum levels were evaluated comparing cases and controls and, among endometrial cancer patients, between high- and low-risk patients. The results demonstrate that DJ-1 levels are significantly higher in cases versus controls and in high- versus low-risk patients. The receiver operating characteristic curve analysis shows that DJ-1 has a very good diagnostic accuracy in discriminating endometrial cancer patients versus controls and an excellent accuracy in distinguishing, among endometrial cancer patients, low- from high-risk cases. DJ-1 sensitivity and specificity are the highest when high- and low-risk patients are compared, reaching the value of 95% and 99%, respectively. Moreover, DJ-1 serum levels seem to be correlated with worsening of the endometrial cancer grade and histotype, making it a reliable tool in the preoperative decision-making process.
Short term depression unmasks the ghost frequency.
Directory of Open Access Journals (Sweden)
Tjeerd V Olde Scheper
Full Text Available Short Term Plasticity (STP has been shown to exist extensively in synapses throughout the brain. Its function is more or less clear in the sense that it alters the probability of synaptic transmission at short time scales. However, it is still unclear what effect STP has on the dynamics of neural networks. We show, using a novel dynamic STP model, that Short Term Depression (STD can affect the phase of frequency coded input such that small networks can perform temporal signal summation and determination with high accuracy. We show that this property of STD can readily solve the problem of the ghost frequency, the perceived pitch of a harmonic complex in absence of the base frequency. Additionally, we demonstrate that this property can explain dynamics in larger networks. By means of two models, one of chopper neurons in the Ventral Cochlear Nucleus and one of a cortical microcircuit with inhibitory Martinotti neurons, it is shown that the dynamics in these microcircuits can reliably be reproduced using STP. Our model of STP gives important insights into the potential roles of STP in self-regulation of cortical activity and long-range afferent input in neuronal microcircuits.
QA support for TFTR reliability improvement program in preparation for DT operation
International Nuclear Information System (INIS)
Parsells, R.F.; Howard, H.P.
1987-01-01
As TFTR approaches experiments in the Q=1 regime, machine reliability becomes a major variable in achieving experimental objectives. This paper describes the methods used to quantify current reliability levels, levels required for D-T operations, proposed methods for reliability growth and improvement, and tracking of reliability performance in that growth. Included in this scope are data collection techniques and short comings, bounding current reliability on the upper end, and requirements for D-T operations. Problem characterization through Pareto diagrams provides insight into recurrent failure modes and the use of Duane plots for charting of reliability changes both cumulative and instantaneous, is explained and demonstrated
Directory of Open Access Journals (Sweden)
Perić Dragoslav M.
2015-01-01
Full Text Available Switchgear for auxiliary low voltage in substations (SS of extra high voltages (EHV to high voltage (HV - SS EHV/HV kV/kV is of special interest for the functioning of these important SS, as it provides a supply for system of protection and other vital functions of SS. The article addresses several characteristic examples involving MV lines with varying degrees of independence of their supply, and the possible application of direct transformation EHV/LV through special voltage transformers. Auxiliary sources such as inverters and diesel generators, which have limited power and expensive energy, are also used for the supply of switchgear for auxiliary low voltage. Corresponding reliability indices are calculated for all examples including mean expected annual engagement of diesel generators. The applicability of certain solutions of switchgear for auxiliary low voltage SS EHV/HV, taking into account their reliability, feasibility and cost-effectiveness is analyzed too. In particular, the analysis of applications of direct transformation EHV/LV for supply of switchgear for auxiliary low voltage, for both new and existing SS EHV/HV.
MEMS reliability: coming of age
Douglass, Michael R.
2008-02-01
In today's high-volume semiconductor world, one could easily take reliability for granted. As the MOEMS/MEMS industry continues to establish itself as a viable alternative to conventional manufacturing in the macro world, reliability can be of high concern. Currently, there are several emerging market opportunities in which MOEMS/MEMS is gaining a foothold. Markets such as mobile media, consumer electronics, biomedical devices, and homeland security are all showing great interest in microfabricated products. At the same time, these markets are among the most demanding when it comes to reliability assurance. To be successful, each company developing a MOEMS/MEMS device must consider reliability on an equal footing with cost, performance and manufacturability. What can this maturing industry learn from the successful development of DLP technology, air bag accelerometers and inkjet printheads? This paper discusses some basic reliability principles which any MOEMS/MEMS device development must use. Examples from the commercially successful and highly reliable Digital Micromirror Device complement the discussion.
Performance and reliability of the Y-Balance TestTM in high school athletes.
Smith, Laura J; Creps, James R; Bean, Ryan; Rodda, Becky; Alsalaheen, Bara
2017-11-07
Lower extremity injuries account for 32.9% of the overall injuries in high school athletes. Previous research has suggested that asymmetry greater than 4cm using the Y-Balance TestTM Lower Quarter (YBT-LQ) in the anterior direction is predictive of non- contact injuries in adults and collegiate athletes. The prevalence of asymmetries or abnormal YBT-LQ performance is not well documented for adolescents. The primary purposes of this study are: 1) to characterize the prevalence of YBT-LQ asymmetries and performance in a cross-sectional sample of adolescents, 2) to examine possible differences in performance on the YBT-LQ between male and female adolescents, and 3) to describe the test-retest reliability of the YBT-LQ in a subsample of adolescents. Observational cross-sectional study. High-school athletes completed the YBT-LQ as main outcome measure. 51 male, 59 female high-school athletes participated in this study. Asymmetries greater than 4cm in the posteromedial (PM) reach direction were most prevalent for male (54.9%) and female (50.8%) participants. Females presented with slightly higher composite scores. Good reliability (ICC = 0.89) was found for the anterior (ANT) direction, and moderate reliability with 0.76 for posterolateral (PL) and 0.63 for PM directions. The MDC95 for the ANT direction was 6% and 12% for both the PL and PM directions. The YBT-LQ performance can be beneficial in assessing recovery in an injured extremity compared to the other limb. However, due to the large MDC95, noted in the PM and PL directions, the differences between sequential testing cannot be attributed to true change in balance unless they exceed the MDC95. In this study, 79% of the athletes presented with at least one asymmetry in YBT-LQ reach distances. Moderate reliability in the PL and PM directions warrants reexamination of the definition of asymmetry in these directions.
Short Assessment of Health Literacy for Portuguese-speaking Adults
Directory of Open Access Journals (Sweden)
Daniel Apolinario
2012-08-01
Full Text Available OBJECTIVE: To develop and validate a short health literacy assessment tool for Portuguese-speaking adults. METHODS: The Short Assessment of Health Literacy for Portuguese-speaking Adults is an assessment tool which consists of 50 items that assess an individual's ability to correctly pronounce and understand common medical terms. We evaluated the instrument's psychometric properties in a convenience sample of 226 Brazilian older adults. Construct validity was assessed by correlating the tool scores with years of schooling, self-reported literacy, and global cognitive functioning. Discrimination validity was assessed by testing the tool's accuracy in detecting inadequate health literacy, defined as failure to fully understand standard medical prescriptions. RESULTS: Moderate to high correlations were found in the assessment of construct validity (Spearman's coefficients ranging from 0.63 to 0.76. The instrument showed adequate internal consistency (Cronbach's alpha=0.93 and adequate test-retest reliability (intraclass correlation coefficient=0.95. The area under the receiver operating characteristic curve for detection of inadequate health literacy was 0.82. A version consisting of 18 items was tested and showed similar psychometric properties. CONCLUSIONS: The instrument developed showed good validity and reliability in a sample of Brazilian older adults. It can be used in research and clinical settings for screening inadequate health literacy.
Standard high-reliability integrated circuit logic packaging. [for deep space tracking stations
Slaughter, D. W.
1977-01-01
A family of standard, high-reliability hardware used for packaging digital integrated circuits is described. The design transition from early prototypes to production hardware is covered and future plans are discussed. Interconnections techniques are described as well as connectors and related hardware available at both the microcircuit packaging and main-frame level. General applications information is also provided.
Jeon, Ki-Yeob
2011-01-01
It is well known that countries with well-structured primary care have better health outcomes, better health equity and reduced healthcare costs. This study aimed to culturally modify and validate the US consumer form of the short Primary Care Assessment Tool (PCAT) in primary care in the Republic of Korea (hereafter referred to as Korea). The Korean consumer form of the short PCAT (KC PCAT) was cross-culturally modified from the original version using a standardised transcultural adaptation method. A pre-test version of the KC PCAT was formulated by replacement of four items and modification of a further four items from the 37 items of the original consumer form of the short PCAT at face value evaluation meetings. Pilot testing was done with a convenience sample of 15 responders at two different sites. Test-retest showed high reliability. To validate the KC PCAT, 606 clients participated in a survey carried out in Korea between February and May 2006. Internal consistency reliability, test-retest reliability and factor analysis were conducted in order to test validity. Psychometric testing was carried out on 37 items of the KC PCAT to make the KS PCAT which has 30 items and has seven principal domains: first contact utilisation, first contact accessibility, ongoing accountable care (ongoing care and coordinated rapport care), integrated care (patient-centred care with integration between primary and specialty care or between different specialties), comprehensive care, community-oriented care and culturally-oriented care. Component factors of the verified KS PCAT explained 58.28% of the total variance in the total item scores of primary care. The verified KS PCAT has been characterised by the seven classic domains of primary care with minor modifications. This may provide clues concerning differences in expectations for primary care in the Korean population as compared with that of the US. The KS PCAT is a reliable and valid tool for the evaluation of the quality of
Forecasting short-run crude oil price using high- and low-inventory variables
International Nuclear Information System (INIS)
Ye, Michael; Zyren, John; Shore, Joanne
2006-01-01
Since inventories have a lower bound or a minimum operating level, economic literature suggests a nonlinear relationship between inventory level and commodity prices. This was found to be the case in the short-run crude oil market. In order to explore this inventory-price relationship, two nonlinear inventory variables are defined and derived from the monthly normal level and relative level of OECD crude oil inventories from post 1991 Gulf War to October 2003: one for the low inventory state and another for the high inventory state of the crude oil market. Incorporation of low- and high-inventory variables in a single equation model to forecast short-run WTI crude oil prices enhances the model fit and forecast ability
Taylor, Zachary
2014-01-01
A practical, step-by-step guide to designing world-class, high availability systems using both classical and DFSS reliability techniques Whether designing telecom, aerospace, automotive, medical, financial, or public safety systems, every engineer aims for the utmost reliability and availability in the systems he, or she, designs. But between the dream of world-class performance and reality falls the shadow of complexities that can bedevil even the most rigorous design process. While there are an array of robust predictive engineering tools, there has been no single-source guide to understan
Short steel and concrete columns under high temperatures
Directory of Open Access Journals (Sweden)
A. E. P. G. A. Jacintho
Full Text Available The growing demand for knowledge about the effect of high temperatures on structures has stimulated increasing research worldwide. This article presents experimental results for short composite steel and concrete columns subjected to high temperatures in ovens with or without an axial compression load, numerically analyzes the temperature distribution in these columns after 30 and 60 minutes and compares them with experimental results. The models consist of concrete-filled tubes of three different thicknesses and two different diameters, and the concrete fill has conventional properties that remained constant for all of the models. The stress-strain behavior of the composite columns was altered after exposure to high temperatures relative to the same columns at room temperature, which was most evident in the 60-minute tests due to the higher temperatures reached. The computational analysis adopted temperature rise curves that were obtained experimentally.
Mechanical Integrity Issues at MCM-Cs for High Reliability Applications
International Nuclear Information System (INIS)
Morgenstern, H.A.; Tarbutton, T.J.; Becka, G.A.; Uribe, F.; Monroe, S.; Burchett, S.
1998-01-01
During the qualification of a new high reliability low-temperature cofired ceramic (LTCC) multichip module (MCM), two issues relating to the electrical and mechanical integrity of the LTCC network were encountered while performing qualification testing. One was electrical opens after aging tests that were caused by cracks in the solder joints. The other was fracturing of the LTCC networks during mechanical testing. Through failure analysis, computer modeling, bend testing, and test samples, changes were identified. Upon implementation of all these changes, the modules passed testing, and the MCM was placed into production
Kim, Jae-Woo; Jeong, Jin-Woo; Kang, Jun-Tae; Choi, Sungyoul; Ahn, Seungjoon; Song, Yoon-Ho
2014-02-01
Highly reliable field electron emitters were developed using a formulation for reproducible damage-free carbon nanotube (CNT) composite pastes with optimal inorganic fillers and a ball-milling method. We carefully controlled the ball-milling sequence and time to avoid any damage to the CNTs, which incorporated fillers that were fully dispersed as paste constituents. The field electron emitters fabricated by printing the CNT pastes were found to exhibit almost perfect adhesion of the CNT emitters to the cathode, along with good uniformity and reproducibility. A high field enhancement factor of around 10 000 was achieved from the CNT field emitters developed. By selecting nano-sized metal alloys and oxides and using the same formulation sequence, we also developed reliable field emitters that could survive high-temperature post processing. These field emitters had high durability to post vacuum annealing at 950 °C, guaranteeing survival of the brazing process used in the sealing of field emission x-ray tubes. We evaluated the field emitters in a triode configuration in the harsh environment of a tiny vacuum-sealed vessel and observed very reliable operation for 30 h at a high current density of 350 mA cm-2. The CNT pastes and related field emitters that were developed could be usefully applied in reliable field emission devices.
Piovesana, Adina M; Harrison, Jessica L; Ducat, Jacob J
2017-12-01
This study aimed to develop a motor-free short-form of the Wechsler Intelligence Scale for Children-Fifth Edition (WISC-V) that allows clinicians to estimate the Full Scale Intelligence Quotients of youths with motor impairments. Using the reliabilities and intercorrelations of six WISC-V motor-free subtests, psychometric methodologies were applied to develop look-up tables for four Motor-free Short-form indices: Verbal Comprehension Short-form, Perceptual Reasoning Short-form, Working Memory Short-form, and a Motor-free Intelligence Quotient. Index-level discrepancy tables were developed using the same methods to allow clinicians to statistically compare visual, verbal, and working memory abilities. The short-form indices had excellent reliabilities ( r = .92-.97) comparable to the original WISC-V. This motor-free short-form of the WISC-V is a reliable alternative for the assessment of intellectual functioning in youths with motor impairments. Clinicians are provided with user-friendly look-up tables, index level discrepancy tables, and base rates, displayed similar to those in the WISC-V manuals to enable interpretation of assessment results.
Bearing capacity and rigidity of short plastic-concrete-tubal vertical columns under transverse load
Dolzhenko, A. V.; Naumov, A. E.; Shevchenko, A. E.
2018-03-01
The results of mathematical modeling in determining strain-stress distribution parameters of a short plastic-concrete-tubal vertical column under horizontal load as those in vertical constructions are described. Quantitative parameters of strain-stress distribution during vertical and horizontal loads and horizontal stiffness were determined by finite element modeling. The internal stress in the concrete column core was analyzed according to equivalent stress in Mohr theory of failure. It was determined that the bearing capacity of a short plastic- concrete-tubal vertical column is 25% higher in resistibility and 15% higher in rigidness than those of the caseless concrete columns equal in size. Cracks formation in the core of a short plastic-concrete-tubal vertical column happens under significantly bigger horizontal loads with less amount of concrete spent than that in caseless concrete columns. The significant increase of bearing capacity and cracking resistance of a short plastic-concrete-tubal vertical column under vertical and horizontal loads allows recommending them as highly effective and highly reliable structural wall elements in civil engineering.
Short Sleep Duration Among Middle School and High School Students - United States, 2015.
Wheaton, Anne G; Jones, Sherry Everett; Cooper, Adina C; Croft, Janet B
2018-01-26
Insufficient sleep among children and adolescents is associated with increased risk for obesity, diabetes, injuries, poor mental health, attention and behavior problems, and poor academic performance (1-4). The American Academy of Sleep Medicine has recommended that, for optimal health, children aged 6-12 years should regularly sleep 9-12 hours per 24 hours and teens aged 13-18 years should sleep 8-10 hours per 24 hours (1). CDC analyzed data from the 2015 national, state, and large urban school district Youth Risk Behavior Surveys (YRBSs) to determine the prevalence of short sleep duration (school nights among middle school and high school students in the United States. In nine states that conducted the middle school YRBS and included a question about sleep duration in their questionnaire, the prevalence of short sleep duration among middle school students was 57.8%, with state-level estimates ranging from 50.2% (New Mexico) to 64.7% (Kentucky). The prevalence of short sleep duration among high school students in the national YRBS was 72.7%. State-level estimates of short sleep duration for the 30 states that conducted the high school YRBS and included a question about sleep duration in their questionnaire ranged from 61.8% (South Dakota) to 82.5% (West Virginia). The large percentage of middle school and high school students who do not get enough sleep on school nights suggests a need for promoting sleep health in schools and at home and delaying school start times to permit students adequate time for sleep.
Short-Term Wind Speed Forecasting for Power System Operations
Zhu, Xinxin
2012-04-01
The emphasis on renewable energy and concerns about the environment have led to large-scale wind energy penetration worldwide. However, there are also significant challenges associated with the use of wind energy due to the intermittent and unstable nature of wind. High-quality short-term wind speed forecasting is critical to reliable and secure power system operations. This article begins with an overview of the current status of worldwide wind power developments and future trends. It then reviews some statistical short-term wind speed forecasting models, including traditional time series approaches and more advanced space-time statistical models. It also discusses the evaluation of forecast accuracy, in particular, the need for realistic loss functions. New challenges in wind speed forecasting regarding ramp events and offshore wind farms are also presented. © 2012 The Authors. International Statistical Review © 2012 International Statistical Institute.
Sullivan, Jennifer L; Rivard, Peter E; Shin, Marlena H; Rosen, Amy K
2016-09-01
The lack of a tool for categorizing and differentiating hospitals according to their high reliability organization (HRO)-related characteristics has hindered progress toward implementing and sustaining evidence-based HRO practices. Hospitals would benefit both from an understanding of the organizational characteristics that support HRO practices and from knowledge about the steps necessary to achieve HRO status to reduce the risk of harm and improve outcomes. The High Reliability Health Care Maturity (HRHCM) model, a model for health care organizations' achievement of high reliability with zero patient harm, incorporates three major domains critical for promoting HROs-Leadership, Safety Culture, and Robust Process Improvement ®. A study was conducted to examine the content validity of the HRHCM model and evaluate whether it can differentiate hospitals' maturity levels for each of the model's components. Staff perceptions of patient safety at six US Department of Veterans Affairs (VA) hospitals were examined to determine whether all 14 HRHCM components were present and to characterize each hospital's level of organizational maturity. Twelve of the 14 components from the HRHCM model were detected; two additional characteristics emerged that are present in the HRO literature but not represented in the model-teamwork culture and system-focused tools for learning and improvement. Each hospital's level of organizational maturity could be characterized for 9 of the 14 components. The findings suggest the HRHCM model has good content validity and that there is differentiation between hospitals on model components. Additional research is needed to understand how these components can be used to build the infrastructure necessary for reaching high reliability.
Trends of HVDC technology - highly reliable converting equipment
International Nuclear Information System (INIS)
Muraoka, Yasuo; Kato, Yasushi; Watanabe, Atsumi; Kano, Takashi; Kawai, Tadao
1983-01-01
At present, the DC power transmission in Japan is practically used for the system connection of relatively small capacity, and the reliability of AC-DC converting system has been proven to exceed the world level by the operational results. However, when the application of this system to trunk power transmission of large capacity in future is considered, it is desirable to raise the reliability of converting equipment further and to develop the stabilized control techniques in harmony with connected AC system. Hitachi Ltd. has developed diversified system-related technologies centering around DC power transmission and the techniques for raising the reliability of converting equipment tending to large capacity. In this report, the results and the future prospect are described. The recent trend of DC power transmission, the development of DC power transmission technology such as the simulation analysis, the stable operation of a DC system connected to a weak AC system and the DC independent transmission from nuclear power stations, the technical development of light direct ignition thyristor bulbs and control protection equipment are reported. (Kako, I.)
Reliability and maintainability assessment factors for reliable fault-tolerant systems
Bavuso, S. J.
1984-01-01
A long term goal of the NASA Langley Research Center is the development of a reliability assessment methodology of sufficient power to enable the credible comparison of the stochastic attributes of one ultrareliable system design against others. This methodology, developed over a 10 year period, is a combined analytic and simulative technique. An analytic component is the Computer Aided Reliability Estimation capability, third generation, or simply CARE III. A simulative component is the Gate Logic Software Simulator capability, or GLOSS. The numerous factors that potentially have a degrading effect on system reliability and the ways in which these factors that are peculiar to highly reliable fault tolerant systems are accounted for in credible reliability assessments. Also presented are the modeling difficulties that result from their inclusion and the ways in which CARE III and GLOSS mitigate the intractability of the heretofore unworkable mathematics.
Secure and Reliable Wireless Communications for Geological Repositories and Nuclear Facilities
International Nuclear Information System (INIS)
Twogood, R.
2015-01-01
There is an important need to develop new generation robust RF communication systems to support wireless communications and instrumentation control in geological repositories and nuclear facilities, such as nuclear power plants. Often these facilities have large metallic structures with electromagnetic (EM) transients from plant equipment. The ambient EMI/RFI harsh environment is responsible for degrading radio link bandwidth. Current communication systems often employ physical cables that are not only expensive to install, but deteriorate over time and are vulnerable to failures. Furthermore, conventional high-power narrowband walkie-talkies sometimes upset other electronics. On the other hand, high-quality reliable wireless communications between operators and automated control systems are critical in these facilities, as wireless sensors become more and more prevalent in these operations. In an effort to develop novel wireless communications systems, Dirac Solutions Inc. (DSI) in collaboration with Lawrence Livermore National Laboratory (LLNL), has developed high-quality ultra-wideband (UWB) hand-held communications systems that have proven to have excellent performance in ships and tunnels. The short pulse UWB RF technology, with bandwidths of many hundreds of MHz's, are non-interfering due to low average power. Furthermore, the UWB link has been shown to be highly reliable in the presence of other interfering signals. The DSI UWB communications systems can be adapted for applications in tunnels and nuclear power facilities for voice, data, and instrumentation control. In this paper we show examples of voice communication in ships with UWB walkie-talkies. We have developed novel modulation and demodulation techniques for short pulse UWB communications. The design is a low-power one and in a compact form. The communication units can be produced inexpensively in large quantities. A major application of these units might be their use by IAEA inspectors and
Wang, Jin-Hui; Zuo, Xi-Nian; Gohel, Suril; Milham, Michael P.; Biswal, Bharat B.; He, Yong
2011-01-01
Graph-based computational network analysis has proven a powerful tool to quantitatively characterize functional architectures of the brain. However, the test-retest (TRT) reliability of graph metrics of functional networks has not been systematically examined. Here, we investigated TRT reliability of topological metrics of functional brain networks derived from resting-state functional magnetic resonance imaging data. Specifically, we evaluated both short-term (5 months apart) TRT reliability for 12 global and 6 local nodal network metrics. We found that reliability of global network metrics was overall low, threshold-sensitive and dependent on several factors of scanning time interval (TI, long-term>short-term), network membership (NM, networks excluding negative correlations>networks including negative correlations) and network type (NT, binarized networks>weighted networks). The dependence was modulated by another factor of node definition (ND) strategy. The local nodal reliability exhibited large variability across nodal metrics and a spatially heterogeneous distribution. Nodal degree was the most reliable metric and varied the least across the factors above. Hub regions in association and limbic/paralimbic cortices showed moderate TRT reliability. Importantly, nodal reliability was robust to above-mentioned four factors. Simulation analysis revealed that global network metrics were extremely sensitive (but varying degrees) to noise in functional connectivity and weighted networks generated numerically more reliable results in compared with binarized networks. For nodal network metrics, they showed high resistance to noise in functional connectivity and no NT related differences were found in the resistance. These findings provide important implications on how to choose reliable analytical schemes and network metrics of interest. PMID:21818285
International Nuclear Information System (INIS)
Chevalier, M.J.; Smith, D.J.; Dean, D.W.
2012-01-01
Deterministic assessments are used to assess the integrity of structural systems operating at high temperature by providing a lower bound lifetime prediction, requiring considerable engineering judgement. However such a result may not satisfy the structural integrity assessment purpose if the results are overly conservative or conversely plant observations (such as failures) could undermine the assessment result if observed before the lower bound lifetime. This paper develops a reliability methodology for high temperature assessments and illustrates the impact and importance of managing the uncertainties within such an analysis. This is done by separating uncertainties into three classifications; aleatory uncertainty, quantifiable epistemic uncertainty and unquantifiable epistemic uncertainty. The result is a reliability model that can predict the behaviour of a structural system based upon plant observations, including failure and survival data. This can be used to reduce the over reliance upon engineering judgement which is prevalent in deterministic assessments. Highlights: ► Deterministic assessments are shown to be heavily reliant upon engineering judgment. ► Based upon the R5 procedure, a reliability model for a structural system is developed. ► Variables must be classified as either aleatory or epistemic to model their impact on reliability. ► Operation experience is then used to reduce reliance upon engineering judgment. ► This results in a model which can predict system behaviour and learn from operational experience.
X-real-time executive (X-RTE) an ultra-high reliable real-time executive for safety critical systems
International Nuclear Information System (INIS)
Suresh Babu, R.M.
1995-01-01
With growing number of application of computers in safety critical systems of nuclear plants there has been a need to assure high quality and reliability of the software used in these systems. One way to assure software quality is to use qualified software components. Since the safety systems and control systems are real-time systems there is a need for a real-time supervisory software to guarantee temporal response of the system. This report describes one such software package, called X-Real-Time Executive (or X-RTE), which was developed in Reactor Control Division, BARC. The report describes all the capabilities and unique features of X-RTE and compares it with a commercially available operating system. The features of X-RTE include pre-emptive scheduling, process synchronization, inter-process communication, multi-processor support, temporal support, debug facility, high portability, high reliability, high quality, and extensive documentation. Examples have been used very liberally to illustrate the underlying concepts. Besides, the report provides a brief description about the methods used, during the software development, to assure high quality and reliability of X-RTE. (author). refs., 11 figs., tabs
Arensman, Remco M; Pisters, Martijn F; de Man-van Ginkel, Janneke M; Schuurmans, Marieke J; Jette, Alan M; de Bie, Rob A
2016-09-01
Adequate and user-friendly instruments for assessing physical function and disability in older adults are vital for estimating and predicting health care needs in clinical practice. The Late-Life Function and Disability Instrument Computer Adaptive Test (LLFDI-CAT) is a promising instrument for assessing physical function and disability in gerontology research and clinical practice. The aims of this study were: (1) to translate the LLFDI-CAT to the Dutch language and (2) to investigate its validity and reliability in a sample of older adults who spoke Dutch and dwelled in the community. For the assessment of validity of the LLFDI-CAT, a cross-sectional design was used. To assess reliability, measurement of the LLFDI-CAT was repeated in the same sample. The item bank of the LLFDI-CAT was translated with a forward-backward procedure. A sample of 54 older adults completed the LLFDI-CAT, World Health Organization Disability Assessment Schedule 2.0, RAND 36-Item Short-Form Health Survey physical functioning scale (10 items), and 10-Meter Walk Test. The LLFDI-CAT was repeated in 2 to 8 days (mean=4.5 days). Pearson's r and the intraclass correlation coefficient (ICC) (2,1) were calculated to assess validity, group-level reliability, and participant-level reliability. A correlation of .74 for the LLFDI-CAT function scale and the RAND 36-Item Short-Form Health Survey physical functioning scale (10 items) was found. The correlations of the LLFDI-CAT disability scale with the World Health Organization Disability Assessment Schedule 2.0 and the 10-Meter Walk Test were -.57 and -.53, respectively. The ICC (2,1) of the LLFDI-CAT function scale was .84, with a group-level reliability score of .85. The ICC (2,1) of the LLFDI-CAT disability scale was .76, with a group-level reliability score of .81. The high percentage of women in the study and the exclusion of older adults with recent joint replacement or hospitalization limit the generalizability of the results. The Dutch LLFDI
Non-dipole effects in multiphoton ionization of hydrogen atom in short superintense laser fields
Energy Technology Data Exchange (ETDEWEB)
Jobunga, Eric O. [AG Moderne Optik, Institut fuer Physik, Humboldt-Universitaet zu Berlin, Newtonstr. 15, D-12489 Berlin (Germany); Department of Mathematics and Physics, Technical University of Mombasa, P. O. Box 90420-80100, Mombasa (Kenya); Saenz, Alejandro [AG Moderne Optik, Institut fuer Physik, Humboldt-Universitaet zu Berlin, Newtonstr. 15, D-12489 Berlin (Germany)
2014-07-01
The development of novel light sources has enabled the realization of high-precision experiments investigating various non-linear processes in the dynamics of atomic, molecular, and ionic systems interacting with high intense laser pulses. At high intensities or short wavelengths, the analysis of these experiments would definitely require a reliable non-perturbative solution of the time-dependent Schroedinger or Dirac equation. These solutions should consider both the temporal and the spatial intensity variations of the laser pulse.We have solved the non-relativistic time dependent Schroedinger equation for a ground state hydrogen atom interacting with short intense spatially and temporally resolved laser fields corresponding to the multiphoton ATI regime for a monochromatic source with λ= 800 nm. We shall analyse the effects of the A{sup 2} term and the corresponding orders of the multipolar expansion of the transition matrix.
Design of short Italian sentences to assess near vision performance.
Calossi, Antonio; Boccardo, Laura; Fossetti, Alessandro; Radner, Wolfgang
2014-01-01
To develop and validate 28 short Italian sentences for the construction of the Italian version of the Radner Reading Chart to simultaneously measure near visual acuity and reading speed. 41 sentences were constructed in Italian language, following the procedure defined by Radner, to obtain "sentence optotypes" with comparable structure and with the same lexical and grammatical difficulty. Sentences were statistically selected and used in 211 normal, non-presbyopic, native Italian-speaking persons. The most equally matched sentences in terms of reading speed and number of reading errors were selected. To assess the validity of the reading speed results obtained with the 28 selected short sentences, we compared the reading speed and reading errors with the average obtained by reading two long 4th-grade paragraphs (97 and 90 words) under the same conditions. The overall mean reading speed of the tested persons was 189±26wpm. The 28 sentences more similar in terms of reading times were selected, achieving a coefficient of variation (the relative SD) of 2.2%. The reliability analyses yielded an overall Cronbach's alpha coefficient of 0.98. The correlation between the short sentences and the long paragraph was high (r=0.85, P<0.0001). The 28 short single Italian sentences optotypes were highly comparable in syntactical structure, number, position, and length of words, lexical difficulty, and reading length. The resulting Italian Radner Reading Chart is precise (high consistency) and practical (short sentences) and therefore useful for research and clinical practice to simultaneously measure near reading acuity and reading speed. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Jonasson, Stina B; Nilsson, Maria H; Lexell, Jan
2017-05-31
Fear of falling is common in people with Parkinson's disease (PD) and is associated with an increased risk for future falls, activity limitations and a reduced quality of life. The Falls Efficacy Scale-International (FES-I) assesses fear of falling conceptualized as concerns about falling. The original FES-I has good psychometric properties in people with PD, but whether this applies also for the short version of FES-I remains to be shown. The aim of the present study was to evaluate the psychometric properties of the short FES-I and to compare these with the original FES-I in the same sample of people with PD. The investigated psychometric properties included known groups validity, data completeness, scaling assumptions, targeting and reliability. A postal survey, which included the original, full-length FES-I, was distributed to 174 people with PD. Responders received a second survey after two weeks. From these data, short FES-I total scores were calculated by extracting the items that are included in the short version of the scale. Median age and PD duration of the 101 responders (43% women) were 73 and 5 years, respectively. The original as well as the short FES-I scores were able to discriminate (p falling, activity avoidance, falls, near falls, and with various self-rated PD severity, respectively. Both versions of FES-I had a high level of data completeness (0.7 to 0.9% missing item responses). Scaling assumptions were acceptable for the original as well as the short FES-I. While the short FES-I had 19% floor effect, the original version was better targeted. Both versions were reliable and obtained high values for internal consistency (Cronbach's alpha >0.8) and test-retest reliability (Intraclass Correlation Coefficient > 0.9). Both the original and short FES-I revealed generally good psychometric properties in people with PD, although the original scale was better targeted. Due to the higher floor effect in the short FES-I, the present findings favors
Reliability and validity of a brief sleep questionnaire for children in Japan.
Okada, Masakazu; Kitamura, Shingo; Iwadare, Yoshitaka; Tachimori, Hisateru; Kamei, Yuichi; Higuchi, Shigekazu; Mishima, Kazuo
2017-09-15
There is a dearth of sleep questionnaires with few items and confirmed reliability and validity that can be used for the early detection of sleep problems in children. The aim of this study was to develop a questionnaire with few items and assess its reliability and validity in both children at high risk of sleep disorders and a community population. Data for analysis were derived from two populations targeted by the Children's Sleep Habits Questionnaire (CSHQ): 178 children attending elementary school and 432 children who visited a pediatric psychiatric hospital (aged 6-12 years). The new questionnaire was constructed as a subset of the CSHQ. The newly developed short version of the sleep questionnaire for children (19 items) had an acceptable internal consistency (0.65). Using the cutoff value of the CSHQ, the total score of the new questionnaire was confirmed to have discriminant validity (27.2 ± 3.9 vs. 22.0 ± 2.1, p questionnaire was significantly correlated with total score (r = 0.81, p questionnaire demonstrated an adequate reliability and validity in both high-risk children and a community population, as well as similar screening ability to the CSHQ. It could thus be a convenient instrument to detect sleep problems in children.
Lee, Sangkyu
Illicit trafficking and smuggling of radioactive materials and special nuclear materials (SNM) are considered as one of the most important recent global nuclear threats. Monitoring the transport and safety of radioisotopes and SNM are challenging due to their weak signals and easy shielding. Great efforts worldwide are focused at developing and improving the detection technologies and algorithms, for accurate and reliable detection of radioisotopes of interest in thus better securing the borders against nuclear threats. In general, radiation portal monitors enable detection of gamma and neutron emitting radioisotopes. Passive or active interrogation techniques, present and/or under the development, are all aimed at increasing accuracy, reliability, and in shortening the time of interrogation as well as the cost of the equipment. Equally important efforts are aimed at advancing algorithms to process the imaging data in an efficient manner providing reliable "readings" of the interiors of the examined volumes of various sizes, ranging from cargos to suitcases. The main objective of this thesis is to develop two synergistic algorithms with the goal to provide highly reliable - low noise identification of radioisotope signatures. These algorithms combine analysis of passive radioactive detection technique with active interrogation imaging techniques such as gamma radiography or muon tomography. One algorithm consists of gamma spectroscopy and cosmic muon tomography, and the other algorithm is based on gamma spectroscopy and gamma radiography. The purpose of fusing two detection methodologies per algorithm is to find both heavy-Z radioisotopes and shielding materials, since radionuclides can be identified with gamma spectroscopy, and shielding materials can be detected using muon tomography or gamma radiography. These combined algorithms are created and analyzed based on numerically generated images of various cargo sizes and materials. In summary, the three detection
Psychometric testing of the properties of the spiritual health scale short form.
Hsiao, Ya-Chu; Chiang, Yi-Chien; Lee, Hsiang-Chun; Han, Chin-Yen
2013-11-01
To further examine the psychometric properties of the spiritual health scale short form, including its reliability and validity. Spirituality is one of the main factors associated with good health outcomes. A reliable and valid instrument to measure spirituality is essential to identify the spiritual needs of an individual and to evaluate the effect of spiritual care. A cross-sectional study design was used. The study was conducted in six nursing schools in northern, central and southern Taiwan. The inclusion criterion for participants was nursing students with clinical practice experience. Initially, 1141 participants were recruited for the study, but 67 were absent and 48 did not complete the questionnaires. A total of 1026 participants were finally recruited, indicating a response rate of 89·9%. The psychometric testing of the spiritual health scale short form included construct validity with confirmatory factor analysis, known-group validity and internal consistency reliability. The results of the confirmatory factor analysis supported the five-factor model as an acceptable model fit. In the known-group validity, the results indicated that people who are in the category of primary religious affiliation have better spiritual health than people in the category of secondary religious affiliation and atheism. The result also indicated that the 24-item spiritual health scale short form achieved an acceptable internal consistency coefficient. The findings suggest that the spiritual health scale short form is a valid and reliable instrument for the appraisal of individual spiritual health. The spiritual health scale short form could provide useful information to guide clinical practice in assessing and managing people's spiritual health in Taiwan. © 2013 John Wiley & Sons Ltd.
Reliability of spring interconnects for high channel-count polyimide electrode arrays
Khan, Sharif; Ordonez, Juan Sebastian; Stieglitz, Thomas
2018-05-01
Active neural implants with a high channel-count need robust and reliable operational assembly for the targeted environment in order to be classified as viable fully implantable systems. The discrete functionality of the electrode array and the implant electronics is vital for intact assembly. A critical interface exists at the interconnection sites between the electrode array and the implant electronics, especially in hybrid assemblies (e.g. retinal implants) where electrodes and electronics are not on the same substrate. Since the interconnects in such assemblies cannot be hermetically sealed, reliable protection against the physiological environment is essential for delivering high insulation resistance and low defusibility of salt ions, which are limited in complexity by current assembly techniques. This work reports on a combination of spring-type interconnects on a polyimide array with silicone rubber gasket insulation for chronically active implantable systems. The spring design of the interconnects on the backend of the electrode array compensates for the uniform thickness of the sandwiched gasket during bonding in assembly and relieves the propagation of extrinsic stresses to the bulk polyimide substrate. The contact resistance of the microflex-bonded spring interconnects with the underlying metallized ceramic test vehicles and insulation through the gasket between adjacent contacts was investigated against the MIL883 standard. The contact and insulation resistances remained stable in the exhausting environmental conditions.
Lee, Yong Seuk; Kim, Min Kyu; Byun, Hae Won; Kim, Sang Bum; Kim, Jin Goo
2015-03-01
The purpose of this study was to verify a recently developed picture-archiving and communications system-photoshop method by comparing reliabilities between real-size paper template and the PACS-photoshop methods in preoperative planning of open-wedge high tibial osteotomy. A prospective case series was conducted, including patients with medial osteoarthritis undergoing open-wedge high tibial osteotomy. In the preoperative planning, the picture-archiving and communications system-photoshop method and real-size paper template method were used simultaneously in all patients. Preoperative hip-knee-ankle angle, height, and angle of the osteotomy were evaluated. The reliability of this newly devised method was evaluated, and the consistency between the two methods was also evaluated using intra-class correlation coefficient. Using the picture-archiving and communications system-photoshop method, the mean correction angle and height of osteotomy gap of rater-1 were 11.7° ± 3.6° and 10.7 ± 3.6 mm, respectively. The mean correction angle and height of osteotomy gap of rater-2 were 12.0 ± 2.6 and 10.8 ± 3.6, respectively. The inter- and intra-rater reliabilities of the correction angle were 0.956 ~ 0.979 and 0.980 ~ 0.992, respectively. The inter- and intra-rater reliabilities of the height of the osteotomy gap were 0.968 ~ 0.985 and 0.971 ~ 0.994, respectively (p photoshop method, mean values of the correction angle and height of the osteotomy gap were 11.9° ± 3.6° and 10.8 ± 3.6 mm, respectively. Consistency between the two methods by comparing the means of the correction angle and the height of the osteotomy gap were 0.985 and 0.985, respectively (p photoshop method enables direct measurement of the height of the osteotomy gap with high reliability.
Reliability Correction for Functional Connectivity: Theory and Implementation
Mueller, Sophia; Wang, Danhong; Fox, Michael D.; Pan, Ruiqi; Lu, Jie; Li, Kuncheng; Sun, Wei; Buckner, Randy L.; Liu, Hesheng
2016-01-01
Network properties can be estimated using functional connectivity MRI (fcMRI). However, regional variation of the fMRI signal causes systematic biases in network estimates including correlation attenuation in regions of low measurement reliability. Here we computed the spatial distribution of fcMRI reliability using longitudinal fcMRI datasets and demonstrated how pre-estimated reliability maps can correct for correlation attenuation. As a test case of reliability-based attenuation correction we estimated properties of the default network, where reliability was significantly lower than average in the medial temporal lobe and higher in the posterior medial cortex, heterogeneity that impacts estimation of the network. Accounting for this bias using attenuation correction revealed that the medial temporal lobe’s contribution to the default network is typically underestimated. To render this approach useful to a greater number of datasets, we demonstrate that test-retest reliability maps derived from repeated runs within a single scanning session can be used as a surrogate for multi-session reliability mapping. Using data segments with different scan lengths between 1 and 30 min, we found that test-retest reliability of connectivity estimates increases with scan length while the spatial distribution of reliability is relatively stable even at short scan lengths. Finally, analyses of tertiary data revealed that reliability distribution is influenced by age, neuropsychiatric status and scanner type, suggesting that reliability correction may be especially important when studying between-group differences. Collectively, these results illustrate that reliability-based attenuation correction is an easily implemented strategy that mitigates certain features of fMRI signal nonuniformity. PMID:26493163
Assessing reliability and useful life of containers for disposal of irradiated fuel waste
International Nuclear Information System (INIS)
Doubt, G.
1984-06-01
Metal containers for fuel waste isolation are to be designed to last at least 500 years to provide a redundant barrier during the decay period of the high activity components of the waste. To meet the long-life requirement, containers must have a very low failure rate during the design mission, a low incidence of 'juvenile failures' due to undetected defects, and resistance to progressive deterioration from environmental processes. This paper summarizes studies to determine: (1) precedent for low failure rates and relevance to container longevity; (b) the likelihood of initial defects perforating the container before or shortly after emplacement, and estimates of material defect distribution; (c) the utility of reliability analysis techniques for estimating reliability and life of fuel waste containers; (d) other approaches to estimating container longevity and failure versus time distribution
Short Circuits of a 10-MW High-Temperature Superconducting Wind Turbine Generator
DEFF Research Database (Denmark)
Song, Xiaowei (Andy); Liu, Dong; Polinder, Henk
2017-01-01
Direct Drive high-temperature superconducting (HTS) wind turbine generators have been proposed to tackle challenges for ever increasing wind turbine ratings. Due to smaller reactances in HTS generators, higher fault currents and larger transient torques could occur if sudden short circuits take...... place at generator terminals. In this paper, a finite element model that couples magnetic fields and the generator's equivalent circuits is developed to simulate short-circuit faults. Afterward, the model is used to study the transient performance of a 10-MW HTS wind turbine generator under four...... show that the short circuits pose great challenges to the generator, and careful consideration should be given to protect the generator. The findings presented in this paper would be beneficial to the design, operation and protection of an HTS wind turbine generator....
DEFF Research Database (Denmark)
Castagna, Carlo; Francini, Lorenzo; Krustrup, Peter
2018-01-01
The aim of this study was to examine the usefulness and reliability characteristics of a repeated sprint ability test considering 5 line sprints of 30-m interspersed with 30-s of active recovery in non-elite outfield young male soccer players. Twenty-six (age 14.9±1.2 years, height 1.72±0.12 cm......, body mass 62.2±5.1 kg) players were tested 48 hours and 7 days apart for 5x30-m performance over 5 trials (T1-T5). Short- (T1-T2) and long-term reliability (T1-T3-T4-T5) were assessed with Intraclass Correlation Coefficient (ICC) and with typical error for measurement (TEM). Short- and long...... study revealed that the 5x30-m sprint test is a reliable field test in the short and long-term when the sum of sprint times and the best sprint performance are considered as outcome variables. Sprint performance decrements variables showed large variability across trials....
PV Systems Reliability Final Technical Report.
Energy Technology Data Exchange (ETDEWEB)
Lavrova, Olga [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Flicker, Jack David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Johnson, Jay [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Armijo, Kenneth Miguel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gonzalez, Sigifredo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schindelholz, Eric John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sorensen, Neil R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Yang, Benjamin Bing-Yeh [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
2015-12-01
The continued exponential growth of photovoltaic technologies paves a path to a solar-powered world, but requires continued progress toward low-cost, high-reliability, high-performance photovoltaic (PV) systems. High reliability is an essential element in achieving low-cost solar electricity by reducing operation and maintenance (O&M) costs and extending system lifetime and availability, but these attributes are difficult to verify at the time of installation. Utilities, financiers, homeowners, and planners are demanding this information in order to evaluate their financial risk as a prerequisite to large investments. Reliability research and development (R&D) is needed to build market confidence by improving product reliability and by improving predictions of system availability, O&M cost, and lifetime. This project is focused on understanding, predicting, and improving the reliability of PV systems. The two areas being pursued include PV arc-fault and ground fault issues, and inverter reliability.
Uchida, Takashi; Takayanagi, Masaru; Kitamura, Taro; Nishio, Toshiyuki; Numata, Yurika; Endo, Wakaba; Haginoya, Kazuhiro; Ohura, Toshihiro
2016-08-01
Acute encephalitis with refractory, repetitive partial seizures (AERRPS) is characterized by repetitive seizures during the acute and chronic phases and has a poor neurological outcome. Burst-suppression coma via continuous i.v. infusion of a short-acting barbiturate is used to terminate refractory seizures, but the severe side-effects of short-acting barbiturates are problematic. We report on a 9-year-old boy with AERRPS who was effectively treated with very-high-dose phenobarbital (VHDPB) combined with intermittent short-acting barbiturates. VHDPB side-effects were mild, especially compared with those associated with continuous i.v. infusion of short-acting barbiturates (dosage, 40-75 mg/kg/day; maximum blood level, 290 μg/mL). Using VHDPB as the main treatment, short-acting barbiturates were used intermittently and in small amounts. This is the first report to show that VHDPB, combined with intermittent short-acting barbiturates, can effectively treat AERRPS. After treatment, convulsions were suppressed and daily life continued, but intellectual impairment and high-level dysfunction remained. © 2016 Japan Pediatric Society.
International Nuclear Information System (INIS)
Korolev, V.V.; Sereda, G.A.
1981-01-01
Nuclear power at the modern stage of development is characterized by utilization of large power commercial reactors high technical specifications and economic parameters of which can be provided only at high reliability of the equipment and high qualification of the personnel. Special educational institution - Institute of nuclear engineering is organized for education of the operation personnel of high qualification for modern NPPs. Discussed are some problems occurring in this connection [ru
Glaister, Mark; Stone, Michael H; Stewart, Andrew M; Hughes, Michael; Moir, Gavin L
2004-08-01
The purpose of the present study was to assess the reliability and validity of fatigue measures, as derived from 4 separate formulae, during tests of repeat sprint ability. On separate days over a 3-week period, 2 groups of 7 recreationally active men completed 6 trials of 1 of 2 maximal (20 x 5 seconds) intermittent cycling tests with contrasting recovery periods (10 or 30 seconds). All trials were conducted on a friction-braked cycle ergometer, and fatigue scores were derived from measures of mean power output for each sprint. Apart from formula 1, which calculated fatigue from the percentage difference in mean power output between the first and last sprint, all remaining formulae produced fatigue scores that showed a reasonably good level of test-retest reliability in both intermittent test protocols (intraclass correlation range: 0.78-0.86; 95% likely range of true values: 0.54-0.97). Although between-protocol differences in the magnitude of the fatigue scores suggested good construct validity, within-protocol differences highlighted limitations with each formula. Overall, the results support the use of the percentage decrement score as the most valid and reliable measure of fatigue during brief maximal intermittent work.
Capacitive effects in IGBTs limiting their reliability under short circuit
DEFF Research Database (Denmark)
Reigosa, Paula Diaz; Iannuzzo, Francesco; Rahimo, Munaf
2017-01-01
The short-circuit oscillation mechanism in IGBTs is investigated in this paper by the aid of semiconductor device simulation tools. A 3.3-kV IGBT cell has been used for the simulations demonstrating that a single IGBT cell is able to oscillate together with the external circuit parasitic elements....... The work presented here through both circuit and device analysis, confirms that the oscillations can be understood with focus on the device capacitive effects coming from the interaction between carrier concentration and the electric field. The paper also shows the 2-D effects during one oscillation cycle...
A single lithium-ion battery protection circuit with high reliability and low power consumption
International Nuclear Information System (INIS)
Jiang Jinguang; Li Sen
2014-01-01
A single lithium-ion battery protection circuit with high reliability and low power consumption is proposed. The protection circuit has high reliability because the voltage and current of the battery are controlled in a safe range. The protection circuit can immediately activate a protective function when the voltage and current of the battery are beyond the safe range. In order to reduce the circuit's power consumption, a sleep state control circuit is developed. Additionally, the output frequency of the ring oscillation can be adjusted continuously and precisely by the charging capacitors and the constant-current source. The proposed protection circuit is fabricated in a 0.5 μm mixed-signal CMOS process. The measured reference voltage is 1.19 V, the overvoltage is 4.2 V and the undervoltage is 2.2 V. The total power is about 9 μW. (semiconductor integrated circuits)
Kang, Donghoon; Kim, Heon-Young; Kim, Dae-Hyun
2014-07-01
The rapid growth of bio-(inspired) sensors has led to an improvement in modern healthcare and human-robot systems in recent years. Higher levels of reliability and better flexibility, essential features of these sensors, are very much required in many application fields (e.g. applications at ultra-high temperatures). Fiber-optic sensors, and fiber Bragg grating (FBG) sensors in particular, are being widely studied as suitable sensors for improved structural health monitoring (SHM) due to their many merits. To enhance the thermal reliability of FBG sensors, thermal sensitivity, generally expressed as αf + ξf and considered a constant, should be investigated more precisely. For this purpose, the governing equation of FBG sensors is modified using differential derivatives between the wavelength shift and the temperature change in this study. Through a thermal test ranging from RT to 900 °C, the thermal sensitivity of FBG sensors is successfully examined and this guarantees thermal reliability of FBG sensors at ultra-high temperatures. In detail, αf + ξf has a non-linear dependence on temperature and varies from 6.0 × 10-6 °C-1 (20 °C) to 10.6 × 10-6 °C-1 (650 °C). Also, FBGs should be carefully used for applications at ultra-high temperatures due to signal disappearance near 900 °C.
Safety and reliability of automatization software
Energy Technology Data Exchange (ETDEWEB)
Kapp, K; Daum, R [Karlsruhe Univ. (TH) (Germany, F.R.). Lehrstuhl fuer Angewandte Informatik, Transport- und Verkehrssysteme
1979-02-01
Automated technical systems have to meet very high requirements concerning safety, security and reliability. Today, modern computers, especially microcomputers, are used as integral parts of those systems. In consequence computer programs must work in a safe and reliable mannter. Methods are discussed which allow to construct safe and reliable software for automatic systems such as reactor protection systems and to prove that the safety requirements are met. As a result it is shown that only the method of total software diversification can satisfy all safety requirements at tolerable cost. In order to achieve a high degree of reliability, structured and modular programming in context with high level programming languages are recommended.
Human Reliability Program Overview
Energy Technology Data Exchange (ETDEWEB)
Bodin, Michael
2012-09-25
This presentation covers the high points of the Human Reliability Program, including certification/decertification, critical positions, due process, organizational structure, program components, personnel security, an overview of the US DOE reliability program, retirees and academia, and security program integration.
Development of high speed and reliable data transmission system for industrial CT
International Nuclear Information System (INIS)
Gao Fuqiang; Dong Yanli; Liu Guohua
2010-01-01
In order to meet the requirements of large capacity,high speed and high reliability of data transmission for industrial CT, a data transmission system based on USB 2.0 was designed. In the process of data transmission, FPGA was the main controller, and USB 2.0 CY7C68013A worked in slave FIFO mode. The system sent the data got from data acquisition system to host computer for image reconstruction. The testing results show that the transmission rate can reach 33 MB/s and the precision is 100%. The system satisfies the requirements of data transmission for industrial CT. (authors)
Cold cathode electron guns in the LASL high power short-pulse CO2 laser program
International Nuclear Information System (INIS)
Singer, S.; Ladish, J.S.; Nutter, M.J.
1975-01-01
The Electron Beam Controlled Discharge CO 2 Laser is now firmly established as the only high power short pulse laser amplifier that has been demonstrated to have scaling capabilities to large apertures and energies much greater than 100 J. These devices require a beam of energetic electrons to control the gas discharge that produces the required population inversion. Until recently, the electron source was usually a thermionic emitter, even for rather large lasers, whose heater requirements dwarfed the pulsed energies associated with the transient operation of the laser. With the advent of reliable cold-cathode electron guns, the operation of these lasers has been greatly simplified. At LASL, there are four electron beam controlled laser systems which are in operation, under construction, or in design: the 1 kJ system, now operational; the 2.5 kJ system; the 10 kJ system; and the 100 kJ system. Only the first uses thermionic-emitter electron guns; the remainder use or will use cold cathode sources. The operation of the 200 x 35 cm 2 two sided cold cathode electron gun used in the 2.5 kJ laser system and to be used in the 10 kJ laser is described
Fault-tolerant design approach for reliable offshore multi-megawatt variable frequency converters
Directory of Open Access Journals (Sweden)
N. Vedachalam
2016-09-01
Full Text Available Inverters play a key role in realizing reliable multi-megawatt power electronic converters used in offshore applications, as their failure leads to production losses and impairs safety. The performance of high power handing semiconductor devices with high speed control capabilities and redundant configurations helps in realizing a fault-tolerant design. This paper describes the reliability modeling done for an industry standard, 3-level neutral point clamped multi-megawatt inverter, the significance of semiconductor redundancy in reducing inverter failure rates, and proposes methods for achieving static and dynamic redundancy in series connected press pack type insulated gate bipolar transistors (IGBT. It is identified that, with the multi megawatt inverter having 3+2 IGBT in each half leg with dynamic redundancy incorporated, it is possible to reduce the failure rate of the inverter from 53.8% to 15% in 5 years of continuous operation. The simulation results indicate that with dynamic redundancy, it is possible to force an untriggered press pack IGBT to short circuit in <1s, when operated with a pulse width modulation frequency of 1kHz.
A high reliability oxygen deficiency monitoring system
International Nuclear Information System (INIS)
Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.
1993-05-01
The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings
A high reliability oxygen deficiency monitoring system
International Nuclear Information System (INIS)
Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.
1993-01-01
The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings
Reliability analyses of safety systems for WWER-440 nuclear power plants
International Nuclear Information System (INIS)
Dusek, J.; Hojny, V.
1985-01-01
The UJV in Rez near Prague studied the reliability of the system of emergency core cooling and of the system for suppressing pressure in the sealed area of the nuclear power plant in the occurrence of a loss-of-coolant accident. The reliability of the systems was evaluated by failure tree analysis. Simulation and analytical calculation programs were developed and used for the reliability analysis. The results are briefly presented of the reliability analyses of the passive system for the immediate short-term flooding of the reactor core, of the active low-pressure system of emergency core cooling, the spray system, the bubble-vacuum system and the system of emergency supply of the steam generators. (E.S.)
Directory of Open Access Journals (Sweden)
Hadeed Ahmed Sher
2016-07-01
Full Text Available Induction motors are widely used in industrial power plants due to their robustness, reliability and high performance under variable operating conditions in the electrical power system. Modern industrial progress is dependent on these ruggedly constructed induction motors. Almost every sophisticated process of the industry is based on induction motors. Most of these motors are controlled by means of inverters that change the line frequency. The change in parameters of inverter makes it possible to control the motor according to the design requirements. The reliability of inverter based motor control is an important issue for industrial applications and therefore, it becomes very vital for design engineers to have comprehensive analysis of the inverter fed induction machine. This paper investigates one of the faults that may occur on the DC link of an inverter fed induction motor. The effect of the capacitor short circuit is presented in this paper. It also deals with the effects of short circuited capacitor on freewheeling diode. DC link capacitors are well designed and even the probability of capacitor failure is high, it is always a rare case if they puncture, however this analysis will add to the reliability of the induction machine under variable operating condition.
Energy Technology Data Exchange (ETDEWEB)
Nakamura, Daisuke; Suzumura, Akitoshi; Shigetoh, Keisuke [Toyota Central R and D Labs., Inc., Nagakute, Aichi 480-1192 (Japan)
2015-02-23
Highly reliable low-cost protective coatings have been sought after for use in crucibles and susceptors for bulk and epitaxial film growth processes involving wide bandgap materials. Here, we propose a production technique for ultra-thick (50–200 μmt) tantalum carbide (TaC) protective coatings on graphite substrates, which consists of TaC slurry application and subsequent sintering processes, i.e., a wet ceramic process. Structural analysis of the sintered TaC layers indicated that they have a dense granular structure containing coarse grain with sizes of 10–50 μm. Furthermore, no cracks or pinholes penetrated through the layers, i.e., the TaC layers are highly reliable protective coatings. The analysis also indicated that no plastic deformation occurred during the production process, and the non-textured crystalline orientation of the TaC layers is the origin of their high reliability and durability. The TaC-coated graphite crucibles were tested in an aluminum nitride (AlN) sublimation growth process, which involves extremely corrosive conditions, and demonstrated their practical reliability and durability in the AlN growth process as a TaC-coated graphite. The application of the TaC-coated graphite materials to crucibles and susceptors for use in bulk AlN single crystal growth, bulk silicon carbide (SiC) single crystal growth, chemical vapor deposition of epitaxial SiC films, and metal-organic vapor phase epitaxy of group-III nitrides will lead to further improvements in crystal quality and reduced processing costs.
International Nuclear Information System (INIS)
Nakamura, Daisuke; Suzumura, Akitoshi; Shigetoh, Keisuke
2015-01-01
Highly reliable low-cost protective coatings have been sought after for use in crucibles and susceptors for bulk and epitaxial film growth processes involving wide bandgap materials. Here, we propose a production technique for ultra-thick (50–200 μmt) tantalum carbide (TaC) protective coatings on graphite substrates, which consists of TaC slurry application and subsequent sintering processes, i.e., a wet ceramic process. Structural analysis of the sintered TaC layers indicated that they have a dense granular structure containing coarse grain with sizes of 10–50 μm. Furthermore, no cracks or pinholes penetrated through the layers, i.e., the TaC layers are highly reliable protective coatings. The analysis also indicated that no plastic deformation occurred during the production process, and the non-textured crystalline orientation of the TaC layers is the origin of their high reliability and durability. The TaC-coated graphite crucibles were tested in an aluminum nitride (AlN) sublimation growth process, which involves extremely corrosive conditions, and demonstrated their practical reliability and durability in the AlN growth process as a TaC-coated graphite. The application of the TaC-coated graphite materials to crucibles and susceptors for use in bulk AlN single crystal growth, bulk silicon carbide (SiC) single crystal growth, chemical vapor deposition of epitaxial SiC films, and metal-organic vapor phase epitaxy of group-III nitrides will lead to further improvements in crystal quality and reduced processing costs
RF-MEMS capacitive switches with high reliability
Goldsmith, Charles L.; Auciello, Orlando H.; Carlisle, John A.; Sampath, Suresh; Sumant, Anirudha V.; Carpick, Robert W.; Hwang, James; Mancini, Derrick C.; Gudeman, Chris
2013-09-03
A reliable long life RF-MEMS capacitive switch is provided with a dielectric layer comprising a "fast discharge diamond dielectric layer" and enabling rapid switch recovery, dielectric layer charging and discharging that is efficient and effective to enable RF-MEMS switch operation to greater than or equal to 100 billion cycles.
High Speed Simulation Framework for Reliable Logic Programs
International Nuclear Information System (INIS)
Lee, Wan-Bok; Kim, Seog-Ju
2006-01-01
This paper shows a case study of designing a PLC logic simulator that was developed to simulate and verify PLC control programs for nuclear plant systems. The nuclear control system requires strict restrictions rather than normal process control system does, since it works with nuclear power plants requiring high reliability under severe environment. One restriction is the safeness of the control programs which can be assured by exploiting severe testing. Another restriction is the simulation speed of the control programs, that should be fast enough to control multi devices concurrently in real-time. To cope with these restrictions, we devised a logic compiler which generates C-code programs from given PLC logic programs. Once the logic program was translated into C-code, the program could be analyzed by conventional software analysis tools and could be used to construct a fast logic simulator after cross-compiling, in fact, that is a kind of compiled-code simulation
Highly Efficient and Reliable Transparent Electromagnetic Interference Shielding Film.
Jia, Li-Chuan; Yan, Ding-Xiang; Liu, Xiaofeng; Ma, Rujun; Wu, Hong-Yuan; Li, Zhong-Ming
2018-04-11
Electromagnetic protection in optoelectronic instruments such as optical windows and electronic displays is challenging because of the essential requirements of a high optical transmittance and an electromagnetic interference (EMI) shielding effectiveness (SE). Herein, we demonstrate the creation of an efficient transparent EMI shielding film that is composed of calcium alginate (CA), silver nanowires (AgNWs), and polyurethane (PU), via a facile and low-cost Mayer-rod coating method. The CA/AgNW/PU film with a high optical transmittance of 92% achieves an EMI SE of 20.7 dB, which meets the requirements for commercial shielding applications. A superior EMI SE of 31.3 dB could be achieved, whereas the transparent film still maintains a transmittance of 81%. The integrated efficient EMI SE and high transmittance are superior to those of most previously reported transparent EMI shielding materials. Moreover, our transparent films exhibit a highly reliable shielding ability in a complex service environment, with 98 and 96% EMI SE retentions even after 30 min of ultrasound treatment and 5000 bending cycles (1.5 mm radius), respectively. The comprehensive performance that is associated with the facile fabrication strategy imparts the CA/AgNW/PU film with great potential as an optimized EMI shielding material in emerging optoelectronic devices, such as flexible solar cells, displays, and touch panels.
The six-item Clock Drawing Test – reliability and validity in mild Alzheimer’s disease
DEFF Research Database (Denmark)
Jørgensen, Kasper; Kristensen, Maria K; Waldemar, Gunhild
2015-01-01
This study presents a reliable, short and practical version of the Clock Drawing Test (CDT) for clinical use and examines its diagnostic accuracy in mild Alzheimer's disease versus elderly nonpatients. Clock drawings from 231 participants were scored independently by four clinical neuropsychologi......This study presents a reliable, short and practical version of the Clock Drawing Test (CDT) for clinical use and examines its diagnostic accuracy in mild Alzheimer's disease versus elderly nonpatients. Clock drawings from 231 participants were scored independently by four clinical...... neuropsychologists blind to diagnostic classification. The interrater agreement of individual scoring criteria was analyzed and items with poor or moderate reliability were excluded. The classification accuracy of the resulting scoring system - the six-item CDT - was examined. We explored the effect of further...
Beauvais, Brad; Richter, Jason; Brezinski, Paul
The 2014 Military Health System Review calls for healthcare system leaders to implement effective strategies used by other high-performing organizations. The authors state, " the [military health system] MHS can create an optimal healthcare environment that focuses on continuous quality improvement where every patient receives safe, high-quality care at all times" (Military Health System, 2014, p. 1). Although aspirational, the document does not specify how a highly reliable health system is developed or what systemic factors are necessary to sustain highly reliable performance. Our work seeks to address this gap and provide guidance to MHS leaders regarding how high-performing organizations develop exceptional levels of performance.The authors' expectation is that military medicine will draw on these lessons to enhance leadership, develop exceptional organizational cultures, onboard and engage employees, build customer loyalty, and improve quality of care. Leaders from other segments of the healthcare field likely will find this study valuable given the size of the military healthcare system (9.6 million beneficiaries), the United States' steady progression toward population-based health, and the increasing need for highly reliable systems and performance.
Novel Low Cost, High Reliability Wind Turbine Drivetrain
Energy Technology Data Exchange (ETDEWEB)
Chobot, Anthony; Das, Debarshi; Mayer, Tyler; Markey, Zach; Martinson, Tim; Reeve, Hayden; Attridge, Paul; El-Wardany, Tahany
2012-09-13
Clipper Windpower, in collaboration with United Technologies Research Center, the National Renewable Energy Laboratory, and Hamilton Sundstrand Corporation, developed a low-cost, deflection-compliant, reliable, and serviceable chain drive speed increaser. This chain and sprocket drivetrain design offers significant breakthroughs in the areas of cost and serviceability and addresses the key challenges of current geared and direct-drive systems. The use of gearboxes has proven to be challenging; the large torques and bending loads associated with use in large multi-MW wind applications have generally limited demonstrated lifetime to 8-10 years [1]. The large cost of gearbox replacement and the required use of large, expensive cranes can result in gearbox replacement costs on the order of $1M, representing a significant impact to overall cost of energy (COE). Direct-drive machines eliminate the gearbox, thereby targeting increased reliability and reduced life-cycle cost. However, the slow rotational speeds require very large and costly generators, which also typically have an undesirable dependence on expensive rare-earth magnet materials and large structural penalties for precise air gap control. The cost of rare-earth materials has increased 20X in the last 8 years representing a key risk to ever realizing the promised cost of energy reductions from direct-drive generators. A common challenge to both geared and direct drive architectures is a limited ability to manage input shaft deflections. The proposed Clipper drivetrain is deflection-compliant, insulating later drivetrain stages and generators from off-axis loads. The system is modular, allowing for all key parts to be removed and replaced without the use of a high capacity crane. Finally, the technology modularity allows for scalability and many possible drivetrain topologies. These benefits enable reductions in drivetrain capital cost by 10.0%, levelized replacement and O&M costs by 26.7%, and overall cost of
Teaching accuracy and reliability for student projects
Fisher, Nick
2002-09-01
Physics students at Rugby School follow the Salters Horners A-level course, which involves working on a two-week practical project of their own choosing. Pupils often misunderstand the concepts of accuracy and reliability, believing, for example, that repeating readings makes them more accurate and more reliable, whereas all it does is help to check repeatability. The course emphasizes the ideas of checking anomalous points, improving accuracy and making readings more sensitive. This article describes how we teach pupils in preparation for their projects. Based on many years of running such projects, much of this material is from a short booklet that we give out to pupils, when we train them in practical project skills.
Study on highly reliable digital communication technology of reactor nuclear measuring equipment
International Nuclear Information System (INIS)
Gu Pengfei; Huang Xiaojin
2007-01-01
To meet the need of highly reliable of reactor nuclear measuring equipment, in allusion to the idiographic request of nuclear measuring equipment, the actual technical development and the application in industrial field, we design a kind of redundancy communication net based on PROFIBUS, and a kind of communication interface module based on redundancy PROFIBUS communication, which link the nuclear measuring equipment and PROFIBUS communication net, and also lay a foundation for advanced research. (authors)
Reliability of the Test of Wheeled Mobility (TOWM) and the Short Wheelie Test
Fliess-Douer, Osnat; Van der Woude, Lucas H. V.; Vanlandewijck, Yves C.
Objective: To assess the reliability of the Test of Wheeled Mobility (TOWM) and the Wheelie test. Design: Cohort study. Setting: Gymnasium. Participants: Manual wheelchair users (N=30, age 23-53y) with a spinal cord injury. Intervention: Participants performed the 30 skills of the TOWM and the 8
Developing Reliable Life Support for Mars
Jones, Harry W.
2017-01-01
A human mission to Mars will require highly reliable life support systems. Mars life support systems may recycle water and oxygen using systems similar to those on the International Space Station (ISS). However, achieving sufficient reliability is less difficult for ISS than it will be for Mars. If an ISS system has a serious failure, it is possible to provide spare parts, or directly supply water or oxygen, or if necessary bring the crew back to Earth. Life support for Mars must be designed, tested, and improved as needed to achieve high demonstrated reliability. A quantitative reliability goal should be established and used to guide development t. The designers should select reliable components and minimize interface and integration problems. In theory a system can achieve the component-limited reliability, but testing often reveal unexpected failures due to design mistakes or flawed components. Testing should extend long enough to detect any unexpected failure modes and to verify the expected reliability. Iterated redesign and retest may be required to achieve the reliability goal. If the reliability is less than required, it may be improved by providing spare components or redundant systems. The number of spares required to achieve a given reliability goal depends on the component failure rate. If the failure rate is under estimated, the number of spares will be insufficient and the system may fail. If the design is likely to have undiscovered design or component problems, it is advisable to use dissimilar redundancy, even though this multiplies the design and development cost. In the ideal case, a human tended closed system operational test should be conducted to gain confidence in operations, maintenance, and repair. The difficulty in achieving high reliability in unproven complex systems may require the use of simpler, more mature, intrinsically higher reliability systems. The limitations of budget, schedule, and technology may suggest accepting lower and
Salyers, M P; McHugo, G J; Cook, J A; Razzano, L A; Drake, R E; Mueser, K T
2001-09-01
Reliability of well-known instruments was examined in 202 people with severe mental illness participating in a multisite vocational study. We examined interrater reliability of the Positive and Negative Syndrome Scale (PANSS) and the internal consistency and test-retest reliability of the PANSS, the Rosenberg Self-Esteem Scale, the Medical Outcomes Study Short Form-36 (SF-36), and the Quality of Life Interview. Most scales had good levels of reliability, with intraclass correlation coefficients (ICCs) and coefficient alphas above .70. However, the SF-36 scales were generally less stable over time, particularly Social Functioning (ICC = .55). Test-retest reliability was lower among less educated respondents and among ethnic minorities. We recommend close monitoring of psychometric issues in future multisite studies.
Modeling and Forecasting (Un)Reliable Realized Covariances for More Reliable Financial Decisions
DEFF Research Database (Denmark)
Bollerslev, Tim; Patton, Andrew J.; Quaedvlieg, Rogier
We propose a new framework for modeling and forecasting common financial risks based on (un)reliable realized covariance measures constructed from high-frequency intraday data. Our new approach explicitly incorporates the effect of measurement errors and time-varying attenuation biases into the c......We propose a new framework for modeling and forecasting common financial risks based on (un)reliable realized covariance measures constructed from high-frequency intraday data. Our new approach explicitly incorporates the effect of measurement errors and time-varying attenuation biases...
Energy Technology Data Exchange (ETDEWEB)
Logan, Jeffrey S. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Paranhos, Elizabeth [Energy Innovation Partners, Seattle, WA (United States); Kozak, Tracy G. [Energy Innovation Partners, Seattle, WA (United States); Boyd, William [Univ. of Colorado, Boulder, CO (United States)
2017-07-31
This study focuses on onshore natural gas operations and examines the extent to which oil and gas firms have embraced certain organizational characteristics that lead to 'high reliability' - understood here as strong safety and reliability records over extended periods of operation. The key questions that motivated this study include whether onshore oil and gas firms engaged in exploration and production (E&P) and midstream (i.e., natural gas transmission and storage) are implementing practices characteristic of high reliability organizations (HROs) and the extent to which any such practices are being driven by industry innovations and standards and/or regulatory requirements.
Toward Massive, Ultrareliable, and Low-Latency Wireless Communication With Short Packets
DEFF Research Database (Denmark)
Durisi, Giuseppe; Koch, Tobias; Popovski, Petar
2016-01-01
Most of the recent advances in the design of high-speed wireless systems are based on information-theoretic principles that demonstrate how to efficiently transmit long data packets. However, the upcoming wireless systems, notably the fifth-generation (5G) system, will need to support novel traffic...... that should be received with low latency and ultrahigh reliability. Current wireless systems are not designed to support short-packet transmissions. For example, the design of current systems relies on the assumption that the metadata (control information) is of negligible size compared to the actual...
Gearbox Reliability Collaborative High Speed Shaft Tapered Roller Bearing Calibration
Energy Technology Data Exchange (ETDEWEB)
Keller, J.; Guo, Y.; McNiff, B.
2013-10-01
The National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) is a project investigating gearbox reliability primarily through testing and modeling. Previous dynamometer testing focused upon acquiring measurements in the planetary section of the test gearbox. Prior to these tests, the strain gages installed on the planetary bearings were calibrated in a load frame.
International Nuclear Information System (INIS)
Kang, Donghoon; Kim, Heon-Young; Kim, Dae-Hyun
2014-01-01
The rapid growth of bio-(inspired) sensors has led to an improvement in modern healthcare and human–robot systems in recent years. Higher levels of reliability and better flexibility, essential features of these sensors, are very much required in many application fields (e.g. applications at ultra-high temperatures). Fiber-optic sensors, and fiber Bragg grating (FBG) sensors in particular, are being widely studied as suitable sensors for improved structural health monitoring (SHM) due to their many merits. To enhance the thermal reliability of FBG sensors, thermal sensitivity, generally expressed as α f + ξ f and considered a constant, should be investigated more precisely. For this purpose, the governing equation of FBG sensors is modified using differential derivatives between the wavelength shift and the temperature change in this study. Through a thermal test ranging from RT to 900 °C, the thermal sensitivity of FBG sensors is successfully examined and this guarantees thermal reliability of FBG sensors at ultra-high temperatures. In detail, α f + ξ f has a non-linear dependence on temperature and varies from 6.0 × 10 −6 °C −1 (20 °C) to 10.6 × 10 −6 °C −1 (650 °C). Also, FBGs should be carefully used for applications at ultra-high temperatures due to signal disappearance near 900 °C. (paper)
Short Circuits of a 10 MW High Temperature Superconducting Wind Turbine Generator
Song, X.; Polinder, H.; Liu, D.; Mijatovic, Nenad; Holbøll, Joachim; Jensen, Bogi Bech
Direct drive high temperature superconducting (HTS) wind turbine generators have been proposed to tackle challenges for ever increasing wind turbine ratings. Due to smaller reactances in HTS generators, higher fault currents and larger transient torques could occur if sudden short circuits happen at
Studies on the reliability of high-field intra-operative MRI in brain glioma resection
Directory of Open Access Journals (Sweden)
Zhi-jun SONG
2011-07-01
Full Text Available Objective To evaluate the reliability of high-field intra-operative magnetic resonance imaging(iMRI in detecting the residual tumors during glioma resection.Method One hundred and thirty-one cases of brain glioma(69 males and 62 females,aged from 7 to 79 years with mean of 39.6 years hospitalized from Nov.2009 to Aug.2010 were involved in present study.All the patients were evaluated using magnetic resonance imaging(MRI before the operation.The tumors were resected under conventional navigation microscope,and the high-field iMRI was used for all the patients when the operators considered the tumor was satisfactorily resected,while the residual tumor was difficult to detect under the microscope,but resected after being revealed by high-field iMRI.Histopathological examination was performed.The patients without residual tumors recieved high-field MRI scan at day 4 or 5 after operation to evaluate the accuracy of high-field iMRI during operation.Results High quality intra-operative images were obtained by using high-field iMRI.Twenty-eight cases were excluded because their residual tumors were not resected due to their location too close to functional area.Combined with the results of intra-operative histopathological examination and post-operative MRI at the early recovery stage,the sensitivity of high-field iMRI in residual tumor diagnosis was 98.0%(49/50,the specificity was 94.3%(50/53,and the accuracy was 96.1%(99/103.Conclusion High-quality intra-operative imaging could be acquired by high-field iMRI,which maybe used as a safe and reliable method in detecting the residual tumors during glioma resection.
Extending ultra-short pulse laser texturing over large area
Energy Technology Data Exchange (ETDEWEB)
Mincuzzi, G., E-mail: girolamo.mincuzzi@alphanov.com; Gemini, L.; Faucon, M.; Kling, R.
2016-11-15
Highlights: • We carried out metal surface texturing (Ripples, micro grooves, Spikes) using a high power, high repetition rate, industrial, Ultra-short pulses laser. • Extremely Fast processing is shown (Laser Scan speed as high as 90 m/s) with a polygon scanner head. • Stainless steel surface blackening with Ultra-short pulses laser has been obtained with unprecedented scanspeed. • Full SEM surface characterization was carried out for all the different structures obtained. • Reflectance measurements were carried out to characterize surface reflectance. - Abstract: Surface texturing by Ultra-Short Pulses Laser (UPL) for industrial applications passes through the use of both fast beam scanning systems and high repetition rate, high average power P, UPL. Nevertheless unwanted thermal effects are expected when P exceeds some tens of W. An interesting strategy for a reliable heat management would consists in texturing with a low fluence values (slightly higher than the ablation threshold) and utilising a Polygon Scanner Heads delivering laser pulses with unrepeated speed. Here we show for the first time that with relatively low fluence it is possible over stainless steel, to obtain surface texturing by utilising a 2 MHz femtosecond laser jointly with a polygonal scanner head in a relatively low fluence regime (0.11 J cm{sup −2}). Different surface textures (Ripples, micro grooves and spikes) can be obtained varying the scan speed from 90 m s{sup −1} to 25 m s{sup −1}. In particular, spikes formation process has been shown and optimised at 25 m s{sup −1} and a full morphology characterization by SEM has been carried out. Reflectance measurements with integrating sphere are presented to compare reference surface with high scan rate textures. In the best case we show a black surface with reflectance value < 5%.
International Nuclear Information System (INIS)
Turati, Pietro; Pedroni, Nicola; Zio, Enrico
2016-01-01
The efficient estimation of system reliability characteristics is of paramount importance for many engineering applications. Real world system reliability modeling calls for the capability of treating systems that are: i) dynamic, ii) complex, iii) hybrid and iv) highly reliable. Advanced Monte Carlo (MC) methods offer a way to solve these types of problems, which are feasible according to the potentially high computational costs. In this paper, the REpetitive Simulation Trials After Reaching Thresholds (RESTART) method is employed, extending it to hybrid systems for the first time (to the authors’ knowledge). The estimation accuracy and precision of RESTART highly depend on the choice of the Importance Function (IF) indicating how close the system is to failure: in this respect, proper IFs are here originally proposed to improve the performance of RESTART for the analysis of hybrid systems. The resulting overall simulation approach is applied to estimate the probability of failure of the control system of a liquid hold-up tank and of a pump-valve subsystem subject to degradation induced by fatigue. The results are compared to those obtained by standard MC simulation and by RESTART with classical IFs available in the literature. The comparison shows the improvement in the performance obtained by our approach. - Highlights: • We consider the issue of estimating small failure probabilities in dynamic systems. • We employ the RESTART method to estimate the failure probabilities. • New Importance Functions (IFs) are introduced to increase the method performance. • We adopt two dynamic, hybrid, highly reliable systems as case studies. • A comparison with literature IFs proves the effectiveness of the new IFs.
An Embedded System for Safe, Secure and Reliable Execution of High Consequence Software
Energy Technology Data Exchange (ETDEWEB)
MCCOY,JAMES A.
2000-08-29
As more complex and functionally diverse requirements are placed on high consequence embedded applications, ensuring safe and secure operation requires an execution environment that is ultra reliable from a system viewpoint. In many cases the safety and security of the system depends upon the reliable cooperation between the hardware and the software to meet real-time system throughput requirements. The selection of a microprocessor and its associated development environment for an embedded application has the most far-reaching effects on the development and production of the system than any other element in the design. The effects of this choice ripple through the remainder of the hardware design and profoundly affect the entire software development process. While state-of-the-art software engineering principles indicate that an object oriented (OO) methodology provides a superior development environment, traditional programming languages available for microprocessors targeted for deeply embedded applications do not directly support OO techniques. Furthermore, the microprocessors themselves do not typically support nor do they enforce an OO environment. This paper describes a system level approach for the design of a microprocessor intended for use in deeply embedded high consequence applications that both supports and enforces an OO execution environment.
Research on reliability measures of the main transformer and GIS equipment manufacturing process
International Nuclear Information System (INIS)
Wu Honglong
2014-01-01
Based on the accidents of the main transformer GIS equipment and the accidents of the high voltage switch equipment, combined with the main transformer switch equipment maintenance experience and electrical theory, the reliability measures of the main transformer GIS equipment during manufacturing stage are studied and improved. Six successful reliability measures are identified: 1) design properly and check the ability of transformer for anti short circuit; 2) choose mature and reliable main transformer HV bushing; 3) choose GIS switch operation mechanism of high quality and reliability; 4) ensure that the insulation margin through tests piece by piece on withstand voltage and partial discharge of the GIS equipment insulation; 5) take test measures such as GIS conductor, shell polishing witness process and full form lightning impulse, to find out and eliminate the defects of abnormal electric field distribution; 6) Anti VFTO design for the main transformer connected with GIS with the voltage of 500 kV should be considered, and its anti VFTO ability to meet the safe operation under VFTO requirements should be checked. This paper proposed 2 new measures: 1) the main transformer insulation material quality standard is determined not only by its high dielectric strength, but more importantly by the homogeneous dielectric electric strength. Insulating Materials with a high and also uniform dielectric strength should be chosen. 2) During the silver-coating stage of the GIS equipment conductor, QC group activities should be organized to ensure that the plating layer quality, and the current lap surface DC resistance measurements should be supervised and witnessed to ensure the quality of the conductor contact surface. These measures are verified in Fuqing project of GIS main transformer equipment manufacturing process, and their effectiveness is proven. (author)
Singendonk, M. M. J.; Smits, M. J.; Heijting, I. E.; van Wijk, M. P.; Nurko, S.; Rosen, R.; Weijenborg, P. W.; Abu-Assi, R.; Hoekman, D. R.; Kuizenga-Wessel, S.; Seiboth, G.; Benninga, M. A.; Omari, T. I.; Kritas, S.
2015-01-01
The Chicago Classification (CC) facilitates interpretation of high-resolution manometry (HRM) recordings. Application of this adult based algorithm to the pediatric population is unknown. We therefore assessed intra and interrater reliability of software-based CC diagnosis in a pediatric cohort.
Reliability and Maintainability Analysis of a High Air Pressure Compressor Facility
Safie, Fayssal M.; Ring, Robert W.; Cole, Stuart K.
2013-01-01
This paper discusses a Reliability, Availability, and Maintainability (RAM) independent assessment conducted to support the refurbishment of the Compressor Station at the NASA Langley Research Center (LaRC). The paper discusses the methodologies used by the assessment team to derive the repair by replacement (RR) strategies to improve the reliability and availability of the Compressor Station (Ref.1). This includes a RAPTOR simulation model that was used to generate the statistical data analysis needed to derive a 15-year investment plan to support the refurbishment of the facility. To summarize, study results clearly indicate that the air compressors are well past their design life. The major failures of Compressors indicate that significant latent failure causes are present. Given the occurrence of these high-cost failures following compressor overhauls, future major failures should be anticipated if compressors are not replaced. Given the results from the RR analysis, the study team recommended a compressor replacement strategy. Based on the data analysis, the RR strategy will lead to sustainable operations through significant improvements in reliability, availability, and the probability of meeting the air demand with acceptable investment cost that should translate, in the long run, into major cost savings. For example, the probability of meeting air demand improved from 79.7 percent for the Base Case to 97.3 percent. Expressed in terms of a reduction in the probability of failing to meet demand (1 in 5 days to 1 in 37 days), the improvement is about 700 percent. Similarly, compressor replacement improved the operational availability of the facility from 97.5 percent to 99.8 percent. Expressed in terms of a reduction in system unavailability (1 in 40 to 1 in 500), the improvement is better than 1000 percent (an order of magnitude improvement). It is worthy to note that the methodologies, tools, and techniques used in the LaRC study can be used to evaluate
Emergency diesel generator reliability analysis high flux isotope reactor
International Nuclear Information System (INIS)
Merryman, L.; Christie, B.
1993-01-01
A program to apply some of the techniques of reliability engineering to the High Flux Isotope Reactor (HFIR) was started on August 8, 1992. Part of the program was to track the conditional probabilities of the emergency diesel generators responding to a valid demand. This was done to determine if the performance of the emergency diesel generators (which are more than 25 years old) has deteriorated. The conditional probabilities of the diesel generators were computed and trended for the period from May 1990 to December 1992. The calculations indicate that the performance of the emergency diesel generators has not deteriorated in recent years, i.e., the conditional probabilities of the emergency diesel generators have been fairly stable over the last few years. This information will be one factor than may be considered in the decision to replace the emergency diesel generators
International Nuclear Information System (INIS)
Yoon, Sang Won; Shiozaki, Koji; Glover, Michael D; Mantooth, H Alan
2013-01-01
This paper presents the feasibility of highly reliable and repeatable copper–tin transient liquid phase (Cu–Sn TLP) bonding as applied to die attachment in high temperature operational power modules. Electrified vehicles are attracting particular interest as eco-friendly vehicles, but their power modules are challenged because of increasing power densities which lead to high temperatures. Such high temperature operation addresses the importance of advanced bonding technology that is highly reliable (for high temperature operation) and repeatable (for fabrication of advanced structures). Cu–Sn TLP bonding is employed herein because of its high remelting temperature and desirable thermal and electrical conductivities. The bonding starts with a stack of Cu–Sn–Cu metal layers that eventually transforms to Cu–Sn alloys. As the alloys have melting temperatures (Cu 3 Sn: > 600 °C, Cu 6 Sn 5 : > 400 °C) significantly higher than the process temperature, the process can be repeated without damaging previously bonded layers. A Cu–Sn TLP bonding process was developed using thin Sn metal sheets inserted between copper layers on silicon die and direct bonded copper substrates, emulating the process used to construct automotive power modules. Bond quality is characterized using (1) proof-of-concept fabrication, (2) material identification using scanning electron microscopy and energy-dispersive x-ray spectroscopy analysis, and (3) optical analysis using optical microscopy and scanning acoustic microscope. The feasibility of multiple-sided Cu–Sn TLP bonding is demonstrated by the absence of bondline damage in multiple test samples fabricated with double- or four-sided bonding using the TLP bonding process. (paper)
Development of high-reliable real-time communication network protocol for SMART
Energy Technology Data Exchange (ETDEWEB)
Song, Ki Sang; Kim, Young Sik [Korea National University of Education, Chongwon (Korea); No, Hee Chon [Korea Advanced Institute of Science and Technology, Taejon (Korea)
1999-04-01
In this research, we first define protocol subsets for SMART(System-integrated Modular Advanced Reactor) communication network based on the requirement of SMART MMIS transmission delay and traffic requirements and OSI(Open System Interconnection) 7 layers' network protocol functions. Also, current industrial purpose LAN protocols are analyzed and the applicability of commercialized protocols are checked. For the suitability test, we have applied approximated SMART data traffic and maximum allowable transmission delay requirement. With the simulation results, we conclude that IEEE 802.5 and FDDI which is an ANSI standard, is the most suitable for SMART. We further analyzed the FDDI and token ring protocols for SMART and nuclear plant network environment including IEEE 802.4, IEEE 802.5, and ARCnet. The most suitable protocol for SMART is FDDI and FDDI MAC and RMT protocol specifications have been verified with LOTOS and the verification results show that FDDI MAC and RMT satisfy the reachability and liveness, but does not show deadlock and livelock. Therefore, we conclude that FDDI MAC and RMT is highly reliable protocol for SMART MMIS network. After that, we consider the stacking fault of IEEE 802.5 token ring protocol and propose a fault tolerant MAM(Modified Active Monitor) protocol. The simulation results show that the MAM protocol improves lower priority traffic service rate when stacking fault occurs. Therefore, proposed MAM protocol can be applied to SMART communication network for high reliability and hard real-time communication purpose in data acquisition and inter channel network. (author). 37 refs., 79 figs., 39 tabs.
Short-course Astronomical Research Seminars for High School and College Students
Johnson, Jolyon
2011-05-01
Since 2008, I have helped lead several short-course astronomical research seminars with Russell M. Genet. These seminars have ranged from semester-long courses at Cuesta College in San Luis Obispo, California to long weekends at the University of Oregon's Pine Mountain Observatory. Each seminar is led by an experienced observer or group of observers who guide high school and college students through the scientific process from observations to publication. The students (anywhere from half a dozen to twenty in number) participate in and contribute to every step. Being a coauthor on one or more research papers offers students an advantage on college and scholarship applications. Similarly, graduate schools often prefer students with research experience. Many topics of research are appropriate for these short-courses including variable star, exoplanet, and asteroid photometry. However, the most successful topic has been visual double stars because the observations required are straitforward and the equipment is relatively inexpensive. The Journal of Double Star Observations is also welcoming of student research and provides swift publication. A detailed description of the short-course seminars can be found in the recent Collins Foundation Press volume titled Small Telescopes and Astronomical Research.
Reliability test and failure analysis of high power LED packages
International Nuclear Information System (INIS)
Chen Zhaohui; Zhang Qin; Wang Kai; Luo Xiaobing; Liu Sheng
2011-01-01
A new type application specific light emitting diode (LED) package (ASLP) with freeform polycarbonate lens for street lighting is developed, whose manufacturing processes are compatible with a typical LED packaging process. The reliability test methods and failure criterions from different vendors are reviewed and compared. It is found that test methods and failure criterions are quite different. The rapid reliability assessment standards are urgently needed for the LED industry. 85 0 C/85 RH with 700 mA is used to test our LED modules with three other vendors for 1000 h, showing no visible degradation in optical performance for our modules, with two other vendors showing significant degradation. Some failure analysis methods such as C-SAM, Nano X-ray CT and optical microscope are used for LED packages. Some failure mechanisms such as delaminations and cracks are detected in the LED packages after the accelerated reliability testing. The finite element simulation method is helpful for the failure analysis and design of the reliability of the LED packaging. One example is used to show one currently used module in industry is vulnerable and may not easily pass the harsh thermal cycle testing. (semiconductor devices)
International Nuclear Information System (INIS)
Wieczorek, A.P.; Wozniak, M.M.; Stankiewicz, A.; Santoro, G.A.; Bogusiewicz, M.; Rechberger, T.
2012-01-01
Objectives: Assessment of the urethral complex and defining its morphological characteristics with 3-dimensional endovaginal ultrasonography with the use of high frequency rotational 360° transducer. Defining inter-observer reliability of the performed measurements. Materials and methods: Twenty-four asymptomatic, nulliparous females (aged 18–55, mean 32 years) underwent high-frequency (12 MHz) endovaginal ultrasound with rotational 360° and automated 3D data acquisition (type 2050, B-K Medical, Herlev, Denmark). Measurements of the urethral thickness, width and length, bladder neck-symphysis distance, intramural part of the urethra as well as rhabdosphincter thickness, width and length were taken by three investigators. Descriptive statistics for continuous data was performed. The results were given as mean values with standard deviation. The relationships among different variables were assessed with ANOVA for repeated measures factors, as well as T-test for dependent samples. Intraclass correlation (ICC) was calculated for each parameter. Intra- and interobserver reliability was assessed. Statistical significance was assigned to a P value of 0.8) and good reliability for rhabdosphincter measurements (ICC > 0.6) between all three investigators. Conclusions: Advanced EVUS provides detailed information on anatomy and morphology of the female urethral complex. Our results show that 360° rotational transducer with automated 3D acquisition, currently routinely used for proctological scanning is suitable for the reliable assessment of the urethral complex and can be applied in a routine diagnostics of pelvic floor disturbances in females.
Statistical estimation Monte Carlo for unreliability evaluation of highly reliable system
International Nuclear Information System (INIS)
Xiao Gang; Su Guanghui; Jia Dounan; Li Tianduo
2000-01-01
Based on analog Monte Carlo simulation, statistical Monte Carlo methods for unreliable evaluation of highly reliable system are constructed, including direct statistical estimation Monte Carlo method and weighted statistical estimation Monte Carlo method. The basal element is given, and the statistical estimation Monte Carlo estimators are derived. Direct Monte Carlo simulation method, bounding-sampling method, forced transitions Monte Carlo method, direct statistical estimation Monte Carlo and weighted statistical estimation Monte Carlo are used to evaluate unreliability of a same system. By comparing, weighted statistical estimation Monte Carlo estimator has smallest variance, and has highest calculating efficiency
DEFF Research Database (Denmark)
Kostandyan, Erik; Ma, Ke
2012-01-01
This paper investigates the lifetime of high power IGBTs (insulated gate bipolar transistors) used in large wind turbine applications. Since the IGBTs are critical components in a wind turbine power converter, it is of great importance to assess their reliability in the design phase of the turbine....... Minimum, maximum and average junction temperatures profiles for the grid side IGBTs are estimated at each wind speed input values. The selected failure mechanism is the crack propagation in solder joint under the silicon die. Based on junction temperature profiles and physics of failure model......, the probabilistic and determinist damage models are presented with estimated fatigue lives. Reliably levels were assessed by means of First Order Reliability Method taking into account uncertainties....
Directory of Open Access Journals (Sweden)
Cariou Bertrand
2013-01-01
Full Text Available Abstract Background PCSK9 (Proprotein Convertase Subtilisin Kexin type 9 is a circulating protein that promotes hypercholesterolemia by decreasing hepatic LDL receptor protein. Under non interventional conditions, its expression is driven by sterol response element binding protein 2 (SREBP2 and follows a diurnal rhythm synchronous with cholesterol synthesis. Plasma PCSK9 is associated to LDL-C and to a lesser extent plasma triglycerides and insulin resistance. We aimed to verify the effect on plasma PCSK9 concentrations of dietary interventions that affect these parameters. Methods We performed nutritional interventions in young healthy male volunteers and offspring of type 2 diabetic (OffT2D patients that are more prone to develop insulin resistance, including: i acute post-prandial hyperlipidemic challenge (n=10, ii 4 days of high-fat (HF or high-fat/high-protein (HFHP (n=10, iii 7 (HFruc1, n=16 or 6 (HFruc2, n=9 days of hypercaloric high-fructose diets. An acute oral fat load was also performed in two patients bearing the R104C-V114A loss-of-function (LOF PCSK9 mutation. Plasma PCSK9 concentrations were measured by ELISA. For the HFruc1 study, intrahepatocellular (IHCL and intramyocellular lipids were measured by 1H magnetic resonance spectroscopy. Hepatic and whole-body insulin sensitivity was assessed with a two-step hyperinsulinemic-euglycemic clamp (0.3 and 1.0 mU.kg-1.min-1. Findings HF and HFHP short-term diets, as well as an acute hyperlipidemic oral load, did not significantly change PCSK9 concentrations. In addition, post-prandial plasma triglyceride excursion was not altered in two carriers of PCSK9 LOF mutation compared with non carriers. In contrast, hypercaloric 7-day HFruc1 diet increased plasma PCSK9 concentrations by 28% (p=0.05 in healthy volunteers and by 34% (p=0.001 in OffT2D patients. In another independent study, 6-day HFruc2 diet increased plasma PCSK9 levels by 93% (p Conclusions Plasma PCSK9 concentrations vary
Pro short-term procurement - Broker/trader
International Nuclear Information System (INIS)
Hoellen, E.E.
1990-01-01
The author presents his opinion on the issue of short-term versus long-term procurement of uranium and enrichment and the impact on reliability of supply. The progression of the market has been one of increasing commoditization. Utility buyers have moved towards purchasing uranium on the spot market and linking long-term contracts to spot-market pricing. There is some logic to the argument that utilities and the industry in general would be best served by this approach. Inventories would be worked off much more quickly, and unnecessary supply would be shut off until prices recovered to profitable levels. The result would be a healthier market with no detriment to the reliability of supply
Wang, X; Jiao, Y; Tang, T; Wang, H; Lu, Z
2013-12-19
Intrinsic connectivity networks (ICNs) are composed of spatial components and time courses. The spatial components of ICNs were discovered with moderate-to-high reliability. So far as we know, few studies focused on the reliability of the temporal patterns for ICNs based their individual time courses. The goals of this study were twofold: to investigate the test-retest reliability of temporal patterns for ICNs, and to analyze these informative univariate metrics. Additionally, a correlation analysis was performed to enhance interpretability. Our study included three datasets: (a) short- and long-term scans, (b) multi-band echo-planar imaging (mEPI), and (c) eyes open or closed. Using dual regression, we obtained the time courses of ICNs for each subject. To produce temporal patterns for ICNs, we applied two categories of univariate metrics: network-wise complexity and network-wise low-frequency oscillation. Furthermore, we validated the test-retest reliability for each metric. The network-wise temporal patterns for most ICNs (especially for default mode network, DMN) exhibited moderate-to-high reliability and reproducibility under different scan conditions. Network-wise complexity for DMN exhibited fair reliability (ICC<0.5) based on eyes-closed sessions. Specially, our results supported that mEPI could be a useful method with high reliability and reproducibility. In addition, these temporal patterns were with physiological meanings, and certain temporal patterns were correlated to the node strength of the corresponding ICN. Overall, network-wise temporal patterns of ICNs were reliable and informative and could be complementary to spatial patterns of ICNs for further study. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.
Design and Analysis of Transport Protocols for Reliable High-Speed Communications
Oláh, A.
1997-01-01
The design and analysis of transport protocols for reliable communications constitutes the topic of this dissertation. These transport protocols guarantee the sequenced and complete delivery of user data over networks which may lose, duplicate and reorder packets. Reliable transport services are
Impact of high temperature and short period annealing on SnS films deposited by E-beam evaporation
International Nuclear Information System (INIS)
Gedi, Sreedevi; Reddy, Vasudeva Reddy Minnam; Kang, Jeong-yoon; Jeon, Chan-Wook
2017-01-01
Highlights: • Preparation SnS films using electron beam evaporation at room temperature. • SnS films were annealed at a high temperaure for different short period of times. • The films showed highly oriented (111) planes with orthorhombic crystal structure. • Surface morphology showed bigger and faceted grains embedded in orthorombic. • The TEM confirmed that big orthorombic slabs had single-crystalline nature. - Abstract: Thin films of SnS were deposited on Mo-substrate using electron beam evaporation at room temperature. As-deposited SnS films were annealed at a constant high temperaure of 860 K for different short period of times, 1 min, 3 min, and 5 min. The impact of heat treatment period on the physical properties of SnS films was investigated using appropriate characterization tools. XRD analysis revealed that the films were highly oriented along (111) plane with orthorhombic crystal structure. Surface morphology of as-deposited SnS films showed an identical leaf texture where as the annealed films showed large orthorombic slab shape grains in adidition to the leaf shape grains, which indicates the significance of short period annealing at high temperature. The transmission electron microscopy confirmed that those large orthorombic slabs had single-crystalline nature. The results emphasized that the short period annealing treatment at high temperature stimulated the growth of film towards the single crystallinity.
Impact of high temperature and short period annealing on SnS films deposited by E-beam evaporation
Energy Technology Data Exchange (ETDEWEB)
Gedi, Sreedevi; Reddy, Vasudeva Reddy Minnam; Kang, Jeong-yoon; Jeon, Chan-Wook, E-mail: cwjeon@ynu.ac.kr
2017-04-30
Highlights: • Preparation SnS films using electron beam evaporation at room temperature. • SnS films were annealed at a high temperaure for different short period of times. • The films showed highly oriented (111) planes with orthorhombic crystal structure. • Surface morphology showed bigger and faceted grains embedded in orthorombic. • The TEM confirmed that big orthorombic slabs had single-crystalline nature. - Abstract: Thin films of SnS were deposited on Mo-substrate using electron beam evaporation at room temperature. As-deposited SnS films were annealed at a constant high temperaure of 860 K for different short period of times, 1 min, 3 min, and 5 min. The impact of heat treatment period on the physical properties of SnS films was investigated using appropriate characterization tools. XRD analysis revealed that the films were highly oriented along (111) plane with orthorhombic crystal structure. Surface morphology of as-deposited SnS films showed an identical leaf texture where as the annealed films showed large orthorombic slab shape grains in adidition to the leaf shape grains, which indicates the significance of short period annealing at high temperature. The transmission electron microscopy confirmed that those large orthorombic slabs had single-crystalline nature. The results emphasized that the short period annealing treatment at high temperature stimulated the growth of film towards the single crystallinity.
Models of Information Security Highly Reliable Computing Systems
Directory of Open Access Journals (Sweden)
Vsevolod Ozirisovich Chukanov
2016-03-01
Full Text Available Methods of the combined reservation are considered. The models of reliability of systems considering parameters of restoration and prevention of blocks of system are described. Ratios for average quantity prevention and an availability quotient of blocks of system are given.
A High Reliability Gas-driven Helium Cryogenic Centrifugal Compressor
Bonneton, M; Gistau-Baguer, Guy M; Turcat, F; Viennot, P
1998-01-01
A helium cryogenic compressor was developed and tested in real conditions in 1996. The achieved objective was to compress 0.018 kg/s Helium at 4 K @ 1000 Pa (10 mbar) up to 3000 Pa (30 mbar). This project was an opportunity to develop and test an interesting new concept in view of future needs. The main features of this new specific technology are described. Particular attention is paid to the gas bearing supported rotor and to the pneumatic driver. Trade off between existing technologies and the present work are presented with special stress on the bearing system and the driver. The advantages are discussed, essentially focused on life time and high reliability without maintenance as well as non pollution characteristic. Practical operational modes are also described together with the experimental performances of the compressor. The article concludes with a brief outlook of future work.
Directory of Open Access Journals (Sweden)
Heidi M. Schambra
2015-09-01
Full Text Available The reliability of transcranial magnetic stimulation (TMS measures in healthy older adults and stroke patients has been insufficiently characterized. We determined whether common TMS measures could reliably evaluate change in individuals and in groups using the smallest detectable change (SDC, or could tell subjects apart using the intraclass correlation coefficient (ICC. We used a single-rater test-retest design in older healthy, subacute stroke, and chronic stroke subjects. At twice daily sessions on two consecutive days, we recorded resting motor threshold, test stimulus intensity, recruitment curves, short-interval intracortical inhibition and facilitation, and long-interval intracortical inhibition. Using variances estimated from a random effects model, we calculated the SDC and ICC for each TMS measure. For all TMS measures in all groups, SDCs for single subjects were large; only with modest group sizes did the SDCs become low. Thus, while these TMS measures cannot be reliably used as a biomarker to detect individual change, they can reliably detect change exceeding measurement noise in moderate-sized groups. For several of the TMS measures, ICCs were universally high, suggesting that they can reliably discriminate between subjects. Though most TMS measures have sufficient reliability in particular contexts, work establishing their validity, responsiveness, and clinical relevance is still needed.
International Nuclear Information System (INIS)
Butterfield, J.M.
1981-01-01
A system is considered where a number of pumps operate in parallel. Normally, all pumps operate, driven by main motors fed from the grid. Each pump has a pony motor fed from an individual battery supply. Each pony motor is normally running, but not engaged to the pump shaft. On demand, e.g. failure of grid supplies, each pony motor is designed to clutch-in automatically when the pump speed falls to a specified value. The probability of all the pony motors failing to clutch-in on demand must be demonstrated with 95% confidence to be less than 10 -8 per demand. This assessment considers how the required reliability of pony motor drives might be demonstrated in practice and the implications on choice of the number of pumps at the design stage. The assessment recognises that not only must the system prove to be extremely reliable, but that demonstration that reliability is adequate must be done during plant commissioning, with practical limits on the amount of testing performed. It is concluded that a minimum of eight pony motors should be provided, eight pumps each with one pony motor (preferred) or five pumps each with two independent pony motors. A minimum of two diverse pony motor systems should be provided. (author)
International Nuclear Information System (INIS)
Nakagawa, K; Tanaka, T; Suzuki, T
2014-01-01
This paper presents the fabrication of a new energy harvesting module that used the thermoelectric device (TED) by using molding technology. The output voltage per heater temperature of the TED module at 20 °C ambient temperature is 8mV/K and similar to the result with the aluminium heat sink which is almost the same fin size as the TED module. The accelerated environmental tests are performed on damp heat test that is an aging test under high temperature and high humidity, cold test and highly accelerated temperature and humidity stress test (HAST) for the purpose of evaluating the electrical reliability in harsh environments. Every result of tests indicates that the TED and circuit board can be properly protected from harsh temperature and humidity by using molding technology, because the output voltage of after tested modules is reduced by less than 5%.This study presents a novel fabrication method for a high reliability TED-installed module appropriate for Machine to Machine wireless sensor networks
Performance and Reliability of Wind Turbines: A Review
Directory of Open Access Journals (Sweden)
Sebastian Pfaffel
2017-11-01
Full Text Available Performance (availability and yield and reliability of wind turbines can make the difference between success and failure of wind farm projects and these factors are vital to decrease the cost of energy. During the last years, several initiatives started to gather data on the performance and reliability of wind turbines on- and offshore and published findings in different journals and conferences. Even though the scopes of the different initiatives are similar, every initiative follows a different approach and results are therefore difficult to compare. The present paper faces this issue, collects results of different initiatives and harmonizes the results. A short description and assessment of every considered data source is provided. To enable this comparison, the existing reliability characteristics are mapped to a system structure according to the Reference Designation System for Power Plants (RDS-PP®. The review shows a wide variation in the performance and reliability metrics of the individual initiatives. Especially the comparison on onshore wind turbines reveals significant differences between the results. Only a few publications are available on offshore wind turbines and the results show an increasing performance and reliability of offshore wind turbines since the first offshore wind farms were erected and monitored.
Reliability Assessment Of Wind Turbines
DEFF Research Database (Denmark)
Sørensen, John Dalsgaard
2014-01-01
Reduction of cost of energy for wind turbines are very important in order to make wind energy competitive compared to other energy sources. Therefore the turbine components should be designed to have sufficient reliability but also not be too costly (and safe). This paper presents models...... for uncertainty modeling and reliability assessment of especially the structural components such as tower, blades, substructure and foundation. But since the function of a wind turbine is highly dependent on many electrical and mechanical components as well as a control system also reliability aspects...... of these components are discussed and it is described how there reliability influences the reliability of the structural components. Two illustrative examples are presented considering uncertainty modeling, reliability assessment and calibration of partial safety factors for structural wind turbine components exposed...
Test-retest reliability of cognitive EEG
McEvoy, L. K.; Smith, M. E.; Gevins, A.
2000-01-01
OBJECTIVE: Task-related EEG is sensitive to changes in cognitive state produced by increased task difficulty and by transient impairment. If task-related EEG has high test-retest reliability, it could be used as part of a clinical test to assess changes in cognitive function. The aim of this study was to determine the reliability of the EEG recorded during the performance of a working memory (WM) task and a psychomotor vigilance task (PVT). METHODS: EEG was recorded while subjects rested quietly and while they performed the tasks. Within session (test-retest interval of approximately 1 h) and between session (test-retest interval of approximately 7 days) reliability was calculated for four EEG components: frontal midline theta at Fz, posterior theta at Pz, and slow and fast alpha at Pz. RESULTS: Task-related EEG was highly reliable within and between sessions (r0.9 for all components in WM task, and r0.8 for all components in the PVT). Resting EEG also showed high reliability, although the magnitude of the correlation was somewhat smaller than that of the task-related EEG (r0.7 for all 4 components). CONCLUSIONS: These results suggest that under appropriate conditions, task-related EEG has sufficient retest reliability for use in assessing clinical changes in cognitive status.
Directory of Open Access Journals (Sweden)
Nicole Gideon
Full Text Available The aim of this study was to develop and validate a short form of the Eating Disorder Examination Questionnaire (EDE-Q for routine, including session by session, outcome assessment.The current, 28-item version (6.0 of the EDE-Q was completed by 489 individuals aged 18-72 with various eating disorders recruited from three UK specialist eating disorder services. Rasch analysis was carried out on factors identified by means of principal component analysis, which in combination with expert ratings informed the development of an EDE-Q short form. The shortened questionnaire's reliability, validity and sensitivity was assessed based on online data collected from students of a UK university and volunteers with a history of eating disorders recruited from a national eating disorders charity aged 18-74 (N = 559.A 12-item short form, the Eating Disorder Examination Questionnaire Short (EDE-QS was derived. The new measure showed high internal consistency (Cronbach's α = .913 and temporal stability (ICC = .93; p < .001. It was highly correlated with the original EDE-Q (r = .91 for people without ED; r = .82 for people with ED and other measures of eating disorder and comorbid psychopathology. It was sufficiently sensitive to distinguish between people with and without eating disorders.The EDE-QS is a brief, reliable and valid measure of eating disorder symptom severity that performs similarly to the EDE-Q and that lends itself for the use of sessional outcome monitoring in treatment and research.
Energy Technology Data Exchange (ETDEWEB)
Moravek, I; Lach, J [Department of Manufacturing Systems, Slovak Technical University Namestie Slobody 17 812 31 Bratislava (Slovakia); Takac, P [Institute of Zoology, SAV, Bratislava (Slovakia)
2012-07-15
Tsetse flies feed only on vertebrate blood, but the collection and processing of blood is expensive, it must be stored at -20{sup o}C requiring costly storage rooms and reliable electricity, and it must be irradiated to reduce bacterial contamination. This is tolerable for small colonies, but as colony size increases to service large- scale programmes, the supply and processing of blood becomes critical. Blood is normally collected from cattle at slaughter. This process is necessarily not aseptic, and large-scale collection is only possible where the animals are suspended for bleeding. One alternative to blood decontamination is using the High Temperature Short time Pasteurization (HTST) method. The food processing industry uses pasteurization to reduce bacterial load in a wide range of products. Our previous results indicated that for the control of the blood pasteurization process, to reach satisfactory bacteriological purity and at the same time to prevent the blood from coagulating, it is important to study temperature and time and also some other parameters that could predict blood coagulation. Crucial for blood coagulation is to study blood viscosity. Classical heat exchangers are not suitable for blood pasteurization. In such equipment the blood coagulation depends on temperature and time. Besides the relatively low temperatures, blood is coagulating with cumulative time until total shutdown of blood flow. After a series of experiments we found a solution using microwave systems. To verify the microwave heating concept, we built an experimental workstation. First we verified the accuracy of the applicator design from the aspect of output adaptation to the power source. Also we installed measuring equipment. This system complies with the requirements of quick heating with sufficiently high heat accumulation. By utilizing standard components for the base of the microwave generator, it is possible to markedly reduce the final price of the equipment. (author)
A reliability model for interlayer dielectric cracking during fast thermal cycling
Nguyen, Van Hieu; Salm, Cora; Krabbenborg, B.H.; Krabbenborg, B.H.; Bisschop, J.; Mouthaan, A.J.; Kuper, F.G.; Ray, Gary W.; Smy, Tom; Ohta, Tomohiro; Tsujimura, Manabu
2003-01-01
Interlayer dielectric (ILD) cracking can result in short circuits of multilevel interconnects. This paper presents a reliability model for ILD cracking induced by fast thermal cycling (FTC) stress. FTC tests have been performed under different temperature ranges (∆T) and minimum temperatures (Tmin).
Reliability of high-voltage pulse capacitors operating in large energy storages
International Nuclear Information System (INIS)
Kuchinskij, G.S.; Fedorova, V.S.; Shilin, O.V.
1982-01-01
To improve the reliability of pulse capacitors operating in capacitive energy storages, processes, resulting in break-down of capacitor insulation were investigated. A statistic model of failures was constructed and reliability of real capacitors, functioning at operating electric intensity Usub(oper) equal 70 kV/mm and at elevated intensity 90 kV/mm was calculated. Results of testing the IK50-ZU4 capacitor are given. The form of the capacitor service life distribution function was specified. To provide and confirm the assigned capacitor reliability, it is necessary to speed up tests at a higher voltage (1.3-1.5) Usub(oper). To improve the capacitor reliability, it is advisable to conduct acceptance tests, which include hold at increased constant voltage (1.3-1.5) Usub(oper) during 1-3 min and the effect of pulses of increased voltage (1.2-1.3) Usub(oper) with the pulse shape corresponding to operating conditions
International Nuclear Information System (INIS)
Pross, G.
Possibilities of optimizing focus machines with a given energy content in the sense of high neutron yield and high reliability of the discharges are investigated experimentally. For this purpose, a focus machine of the Mather type with an energy content of 12 kJ was constructed. The following experimental parameters were varied: the material of the insulator in the ignition zone, the structure of the outside electrode, the length of the inside electrode, the filling pressure and the amount and polarity of the battery voltage. An important part of the diagnostic program consists of measurements of the azimuthal and axial current distribution in the accelerator, correlated with short-term photographs of the luminous front as a function of time. The results are given. A functional schematic has been drafted for focus discharge as an aid in extensive optimization of focus machines, combining findings from theory and experiments. The schematic takes into account the multiparameter character of the discharge and clarifies relationships between the experimental parameters and the target variables neutron yield and reliability
Li, W. W.; Du, Z. Z.; Yuan, R. m.; Xiong, D. Z.; Shi, E. W.; Lu, G. N.; Dai, Z. Y.; Chen, X. Q.; Jiang, Z. Y.; Lv, Y. G.
2017-10-01
Smart meter represents the development direction of energy-saving smart grid in the future. The load switch, one of the core parts of smart meter, should be of high reliability, safety and endurance capability of limit short-circuit current. For this reason, this paper discusses the quick simulation of relationship between attraction and counterforce of load switch without iteration, establishes dual response surface model of attraction and counterforce and optimizes the design scheme of load switch for charge control smart meter, thus increasing electromagnetic attraction and spring counterforce. In this way, this paper puts forward a method to improve the withstand capacity of limit short-circuit current.
Huang, Min; Liu, Zhaoqing; Qiao, Liyan
2014-01-01
While the NAND flash memory is widely used as the storage medium in modern sensor systems, the aggressive shrinking of process geometry and an increase in the number of bits stored in each memory cell will inevitably degrade the reliability of NAND flash memory. In particular, it's critical to enhance metadata reliability, which occupies only a small portion of the storage space, but maintains the critical information of the file system and the address translations of the storage system. Metadata damage will cause the system to crash or a large amount of data to be lost. This paper presents Asymmetric Programming, a highly reliable metadata allocation strategy for MLC NAND flash memory storage systems. Our technique exploits for the first time the property of the multi-page architecture of MLC NAND flash memory to improve the reliability of metadata. The basic idea is to keep metadata in most significant bit (MSB) pages which are more reliable than least significant bit (LSB) pages. Thus, we can achieve relatively low bit error rates for metadata. Based on this idea, we propose two strategies to optimize address mapping and garbage collection. We have implemented Asymmetric Programming on a real hardware platform. The experimental results show that Asymmetric Programming can achieve a reduction in the number of page errors of up to 99.05% with the baseline error correction scheme. PMID:25310473
Directory of Open Access Journals (Sweden)
Min Huang
2014-10-01
Full Text Available While the NAND flash memory is widely used as the storage medium in modern sensor systems, the aggressive shrinking of process geometry and an increase in the number of bits stored in each memory cell will inevitably degrade the reliability of NAND flash memory. In particular, it’s critical to enhance metadata reliability, which occupies only a small portion of the storage space, but maintains the critical information of the file system and the address translations of the storage system. Metadata damage will cause the system to crash or a large amount of data to be lost. This paper presents Asymmetric Programming, a highly reliable metadata allocation strategy for MLC NAND flash memory storage systems. Our technique exploits for the first time the property of the multi-page architecture of MLC NAND flash memory to improve the reliability of metadata. The basic idea is to keep metadata in most significant bit (MSB pages which are more reliable than least significant bit (LSB pages. Thus, we can achieve relatively low bit error rates for metadata. Based on this idea, we propose two strategies to optimize address mapping and garbage collection. We have implemented Asymmetric Programming on a real hardware platform. The experimental results show that Asymmetric Programming can achieve a reduction in the number of page errors of up to 99.05% with the baseline error correction scheme.
Creating High Reliability Teams in Healthcare through In situ Simulation Training
Directory of Open Access Journals (Sweden)
Kristi Miller RN
2011-07-01
Full Text Available The importance of teamwork on patient safety in healthcare has been well established. However, the theory and research of healthcare teams are seriously lacking in clinical application. While conventional team theory assumes that teams are stable and leadership is constant, a growing body of evidence indicates that most healthcare teams are unstable and lack constant leadership. For healthcare organizations to reduce error and ensure patient safety, the true nature of healthcare teams must be better understood. This study presents a taxonomy of healthcare teams and the determinants of high reliability in healthcare teams based on a series of studies undertaken over a five-year period (2005–2010.
Koen, Joshua D; Borders, Alyssa A; Petzold, Michael T; Yonelinas, Andrew P
2017-02-01
The medial temporal lobe (MTL) plays a critical role in episodic long-term memory, but whether the MTL is necessary for visual short-term memory is controversial. Some studies have indicated that MTL damage disrupts visual short-term memory performance whereas other studies have failed to find such evidence. To account for these mixed results, it has been proposed that the hippocampus is critical in supporting short-term memory for high resolution complex bindings, while the cortex is sufficient to support simple, low resolution bindings. This hypothesis was tested in the current study by assessing visual short-term memory in patients with damage to the MTL and controls for high resolution and low resolution object-location and object-color associations. In the location tests, participants encoded sets of two or four objects in different locations on the screen. After each set, participants performed a two-alternative forced-choice task in which they were required to discriminate the object in the target location from the object in a high or low resolution lure location (i.e., the object locations were very close or far away from the target location, respectively). Similarly, in the color tests, participants were presented with sets of two or four objects in a different color and, after each set, were required to discriminate the object in the target color from the object in a high or low resolution lure color (i.e., the lure color was very similar or very different, respectively, to the studied color). The patients were significantly impaired in visual short-term memory, but importantly, they were more impaired for high resolution object-location and object-color bindings. The results are consistent with the proposal that the hippocampus plays a critical role in forming and maintaining complex, high resolution bindings. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
A reliability analysis of the revised competitiveness index.
Harris, Paul B; Houston, John M
2010-06-01
This study examined the reliability of the Revised Competitiveness Index by investigating the test-retest reliability, interitem reliability, and factor structure of the measure based on a sample of 280 undergraduates (200 women, 80 men) ranging in age from 18 to 28 years (M = 20.1, SD = 2.1). The findings indicate that the Revised Competitiveness Index has high test-retest reliability, high inter-item reliability, and a stable factor structure. The results support the assertion that the Revised Competitiveness Index assesses competitiveness as a stable trait rather than a dynamic state.
Genometa--a fast and accurate classifier for short metagenomic shotgun reads.
Davenport, Colin F; Neugebauer, Jens; Beckmann, Nils; Friedrich, Benedikt; Kameri, Burim; Kokott, Svea; Paetow, Malte; Siekmann, Björn; Wieding-Drewes, Matthias; Wienhöfer, Markus; Wolf, Stefan; Tümmler, Burkhard; Ahlers, Volker; Sprengel, Frauke
2012-01-01
Metagenomic studies use high-throughput sequence data to investigate microbial communities in situ. However, considerable challenges remain in the analysis of these data, particularly with regard to speed and reliable analysis of microbial species as opposed to higher level taxa such as phyla. We here present Genometa, a computationally undemanding graphical user interface program that enables identification of bacterial species and gene content from datasets generated by inexpensive high-throughput short read sequencing technologies. Our approach was first verified on two simulated metagenomic short read datasets, detecting 100% and 94% of the bacterial species included with few false positives or false negatives. Subsequent comparative benchmarking analysis against three popular metagenomic algorithms on an Illumina human gut dataset revealed Genometa to attribute the most reads to bacteria at species level (i.e. including all strains of that species) and demonstrate similar or better accuracy than the other programs. Lastly, speed was demonstrated to be many times that of BLAST due to the use of modern short read aligners. Our method is highly accurate if bacteria in the sample are represented by genomes in the reference sequence but cannot find species absent from the reference. This method is one of the most user-friendly and resource efficient approaches and is thus feasible for rapidly analysing millions of short reads on a personal computer. The Genometa program, a step by step tutorial and Java source code are freely available from http://genomics1.mh-hannover.de/genometa/ and on http://code.google.com/p/genometa/. This program has been tested on Ubuntu Linux and Windows XP/7.
Genometa--a fast and accurate classifier for short metagenomic shotgun reads.
Directory of Open Access Journals (Sweden)
Colin F Davenport
Full Text Available Metagenomic studies use high-throughput sequence data to investigate microbial communities in situ. However, considerable challenges remain in the analysis of these data, particularly with regard to speed and reliable analysis of microbial species as opposed to higher level taxa such as phyla. We here present Genometa, a computationally undemanding graphical user interface program that enables identification of bacterial species and gene content from datasets generated by inexpensive high-throughput short read sequencing technologies. Our approach was first verified on two simulated metagenomic short read datasets, detecting 100% and 94% of the bacterial species included with few false positives or false negatives. Subsequent comparative benchmarking analysis against three popular metagenomic algorithms on an Illumina human gut dataset revealed Genometa to attribute the most reads to bacteria at species level (i.e. including all strains of that species and demonstrate similar or better accuracy than the other programs. Lastly, speed was demonstrated to be many times that of BLAST due to the use of modern short read aligners. Our method is highly accurate if bacteria in the sample are represented by genomes in the reference sequence but cannot find species absent from the reference. This method is one of the most user-friendly and resource efficient approaches and is thus feasible for rapidly analysing millions of short reads on a personal computer.The Genometa program, a step by step tutorial and Java source code are freely available from http://genomics1.mh-hannover.de/genometa/ and on http://code.google.com/p/genometa/. This program has been tested on Ubuntu Linux and Windows XP/7.
Test results of reliable and very high capillary multi-evaporators / condenser loop
Energy Technology Data Exchange (ETDEWEB)
Van Oost, S; Dubois, M; Bekaert, G [Societe Anonyme Belge de Construction Aeronautique - SABCA (Belgium)
1997-12-31
The paper present the results of various SABCA activities in the field of two-phase heat transport system. These results have been based on a critical review and analysis of the existing two-phase loop and of the future loop needs in space applications. The research and the development of a high capillary wick (capillary pressure up to 38 000 Pa) are described. These activities have led towards the development of a reliable high performance capillary loop concept (HPCPL), which is discussed in details. Several loop configurations mono/multi-evaporators have been ground tested. The presented results of various tests clearly show the viability of this concept for future applications. Proposed flight demonstrations as well as potential applications conclude this paper. (authors) 7 refs.
Test results of reliable and very high capillary multi-evaporators / condenser loop
Energy Technology Data Exchange (ETDEWEB)
Van Oost, S.; Dubois, M.; Bekaert, G. [Societe Anonyme Belge de Construction Aeronautique - SABCA (Belgium)
1996-12-31
The paper present the results of various SABCA activities in the field of two-phase heat transport system. These results have been based on a critical review and analysis of the existing two-phase loop and of the future loop needs in space applications. The research and the development of a high capillary wick (capillary pressure up to 38 000 Pa) are described. These activities have led towards the development of a reliable high performance capillary loop concept (HPCPL), which is discussed in details. Several loop configurations mono/multi-evaporators have been ground tested. The presented results of various tests clearly show the viability of this concept for future applications. Proposed flight demonstrations as well as potential applications conclude this paper. (authors) 7 refs.
Improving the Test-Retest Reliability of Resting State fMRI by Removing the Impact of Sleep.
Wang, Jiahui; Han, Junwei; Nguyen, Vinh T; Guo, Lei; Guo, Christine C
2017-01-01
Resting state functional magnetic resonance imaging (rs-fMRI) provides a powerful tool to examine large-scale neural networks in the human brain and their disturbances in neuropsychiatric disorders. Thanks to its low demand and high tolerance, resting state paradigms can be easily acquired from clinical population. However, due to the unconstrained nature, resting state paradigm is associated with excessive head movement and proneness to sleep. Consequently, the test-retest reliability of rs-fMRI measures is moderate at best, falling short of widespread use in the clinic. Here, we characterized the effect of sleep on the test-retest reliability of rs-fMRI. Using measures of heart rate variability (HRV) derived from simultaneous electrocardiogram (ECG) recording, we identified portions of fMRI data when subjects were more alert or sleepy, and examined their effects on the test-retest reliability of functional connectivity measures. When volumes of sleep were excluded, the reliability of rs-fMRI is significantly improved, and the improvement appears to be general across brain networks. The amount of improvement is robust with the removal of as much as 60% volumes of sleepiness. Therefore, test-retest reliability of rs-fMRI is affected by sleep and could be improved by excluding volumes of sleepiness as indexed by HRV. Our results suggest a novel and practical method to improve test-retest reliability of rs-fMRI measures.
A Step Toward High Reliability: Implementation of a Daily Safety Brief in a Children's Hospital.
Saysana, Michele; McCaskey, Marjorie; Cox, Elaine; Thompson, Rachel; Tuttle, Lora K; Haut, Paul R
2017-09-01
Health care is a high-risk industry. To improve communication about daily events and begin the journey toward a high reliability organization, the Riley Hospital for Children at Indiana University Health implemented a daily safety brief. Various departments in our children's hospital were asked to participate in a daily safety brief, reporting daily events and unexpected outcomes within their scope of responsibility. Participants were surveyed before and after implementation of the safety brief about communication and awareness of events in the hospital. The length of the brief and percentage of departments reporting unexpected outcomes were measured. The analysis of the presurvey and the postsurvey showed a statistically significant improvement in the questions related to the awareness of daily events as well as communication and relationships between departments. The monthly mean length of time for the brief was 15 minutes or less. Unexpected outcomes were reported by 50% of the departments for 8 months. A daily safety brief can be successfully implemented in a children's hospital. Communication between departments and awareness of daily events were improved. Implementation of a daily safety brief is a step toward becoming a high reliability organization.
Palm, Peter; Josephson, Malin; Mathiassen, Svend Erik; Kjellberg, Katarina
2016-06-01
We evaluated the intra- and inter-observer reliability and criterion validity of an observation protocol, developed in an iterative process involving practicing ergonomists, for assessment of working technique during cash register work for the purpose of preventing upper extremity symptoms. Two ergonomists independently assessed 17 15-min videos of cash register work on two occasions each, as a basis for examining reliability. Criterion validity was assessed by comparing these assessments with meticulous video-based analyses by researchers. Intra-observer reliability was acceptable (i.e. proportional agreement >0.7 and kappa >0.4) for 10/10 questions. Inter-observer reliability was acceptable for only 3/10 questions. An acceptable inter-observer reliability combined with an acceptable criterion validity was obtained only for one working technique aspect, 'Quality of movements'. Thus, major elements of the cashiers' working technique could not be assessed with an acceptable accuracy from short periods of observations by one observer, such as often desired by practitioners. Practitioner Summary: We examined an observation protocol for assessing working technique in cash register work. It was feasible in use, but inter-observer reliability and criterion validity were generally not acceptable when working technique aspects were assessed from short periods of work. We recommend the protocol to be used for educational purposes only.
Challenges Regarding IP Core Functional Reliability
Berg, Melanie D.; LaBel, Kenneth A.
2017-01-01
For many years, intellectual property (IP) cores have been incorporated into field programmable gate array (FPGA) and application specific integrated circuit (ASIC) design flows. However, the usage of large complex IP cores were limited within products that required a high level of reliability. This is no longer the case. IP core insertion has become mainstream including their use in highly reliable products. Due to limited visibility and control, challenges exist when using IP cores and subsequently compromise product reliability. We discuss challenges and suggest potential solutions to critical application IP insertion.
Reliability of high mobility SiGe channel MOSFETs for future CMOS applications
Franco, Jacopo; Groeseneken, Guido
2014-01-01
Due to the ever increasing electric fields in scaled CMOS devices, reliability is becoming a showstopper for further scaled technology nodes. Although several groups have already demonstrated functional Si channel devices with aggressively scaled Equivalent Oxide Thickness (EOT) down to 5Å, a 10 year reliable device operation cannot be guaranteed anymore due to severe Negative Bias Temperature Instability. This book focuses on the reliability of the novel (Si)Ge channel quantum well pMOSFET technology. This technology is being considered for possible implementation in next CMOS technology nodes, thanks to its benefit in terms of carrier mobility and device threshold voltage tuning. We observe that it also opens a degree of freedom for device reliability optimization. By properly tuning the device gate stack, sufficiently reliable ultra-thin EOT devices with a 10 years lifetime at operating conditions are demonstrated. The extensive experimental datasets collected on a variety of processed 300mm wafers and pr...
Reliability of Beam Loss Monitors System for the Large Hadron Collider
Guaglio, G.; Dehning, B.; Santoni, C.
2004-11-01
The employment of superconducting magnets in high energy colliders opens challenging failure scenarios and brings new criticalities for the whole system protection. For the LHC beam loss protection system, the failure rate and the availability requirements have been evaluated using the Safety Integrity Level (SIL) approach. A downtime cost evaluation is used as input for the SIL approach. The most critical systems, which contribute to the final SIL value, are the dump system, the interlock system, the beam loss monitors system and the energy monitor system. The Beam Loss Monitors System (BLMS) is critical for short and intense particle losses, while at medium and higher loss time it is assisted by other systems, such as the quench protection system and the cryogenic system. For BLMS, hardware and software have been evaluated in detail. The reliability input figures have been collected using historical data from the SPS, using temperature and radiation damage experimental data as well as using standard databases. All the data have been processed by reliability software (Isograph). The analysis ranges from the components data to the system configuration.
Reliability of Beam Loss Monitors System for the Large Hadron Collider
International Nuclear Information System (INIS)
Guaglio, G.; Dehning, B.; Santoni, C.
2004-01-01
The employment of superconducting magnets in high energy colliders opens challenging failure scenarios and brings new criticalities for the whole system protection. For the LHC beam loss protection system, the failure rate and the availability requirements have been evaluated using the Safety Integrity Level (SIL) approach. A downtime cost evaluation is used as input for the SIL approach. The most critical systems, which contribute to the final SIL value, are the dump system, the interlock system, the beam loss monitors system and the energy monitor system. The Beam Loss Monitors System (BLMS) is critical for short and intense particle losses, while at medium and higher loss time it is assisted by other systems, such as the quench protection system and the cryogenic system. For BLMS, hardware and software have been evaluated in detail. The reliability input figures have been collected using historical data from the SPS, using temperature and radiation damage experimental data as well as using standard databases. All the data have been processed by reliability software (Isograph). The analysis ranges from the components data to the system configuration
Epperlein, Peter W
2013-01-01
This reference book provides a fully integrated novel approach to the development of high-power, single-transverse mode, edge-emitting diode lasers by addressing the complementary topics of device engineering, reliability engineering and device diagnostics in the same book, and thus closes the gap in the current book literature. Diode laser fundamentals are discussed, followed by an elaborate discussion of problem-oriented design guidelines and techniques, and by a systematic treatment of the origins of laser degradation and a thorough exploration of the engineering means to enhance the optical strength of the laser. Stability criteria of critical laser characteristics and key laser robustness factors are discussed along with clear design considerations in the context of reliability engineering approaches and models, and typical programs for reliability tests and laser product qualifications. Novel, advanced diagnostic methods are reviewed to discuss, for the first time in detail in book literature, performa...
International Nuclear Information System (INIS)
Lee, Chi Woo; Kim, Sun Jin; Lee, Seung Woo; Jeong, Sang Yeong
1993-08-01
This book start what is reliability? such as origin of reliability problems, definition of reliability and reliability and use of reliability. It also deals with probability and calculation of reliability, reliability function and failure rate, probability distribution of reliability, assumption of MTBF, process of probability distribution, down time, maintainability and availability, break down maintenance and preventive maintenance design of reliability, design of reliability for prediction and statistics, reliability test, reliability data and design and management of reliability.
Reliability and radiation effects in compound semiconductors
Johnston, Allan
2010-01-01
This book discusses reliability and radiation effects in compound semiconductors, which have evolved rapidly during the last 15 years. Johnston's perspective in the book focuses on high-reliability applications in space, but his discussion of reliability is applicable to high reliability terrestrial applications as well. The book is important because there are new reliability mechanisms present in compound semiconductors that have produced a great deal of confusion. They are complex, and appear to be major stumbling blocks in the application of these types of devices. Many of the reliability problems that were prominent research topics five to ten years ago have been solved, and the reliability of many of these devices has been improved to the level where they can be used for ten years or more with low failure rates. There is also considerable confusion about the way that space radiation affects compound semiconductors. Some optoelectronic devices are so sensitive to damage in space that they are very difficu...
The Yo-Yo intermittent recovery test level 1 is reliable in young high-level soccer players
Directory of Open Access Journals (Sweden)
Dieter Deprez
2014-11-01
Full Text Available The aim of the study was to investigate test reliability of the Yo-Yo intermittent recovery test level 1 (YYIR1 in 36 high-level youth soccer players, aged between 13 and 18 years. Players were divided into three age groups (U15, U17 and U19 and completed three YYIR1 in three consecutive weeks. Pairwise comparisons were used to investigate test reliability (for distances and heart rate responses using technical error (TE, coefficient of variation (CV, intra-class correlation (ICC and limits of agreement (LOA with Bland-Altman plots. The mean YYIR1 distances for the U15, U17 and U19 groups were 2024 ± 470 m, 2404 ± 347 m and 2547 ± 337 m, respectively. The results revealed that the TEs varied between 74 and 172 m, CVs between 3.0 and 7.5%, and ICCs between 0.87 and 0.95 across all age groups for the YYIR1 distance. For heart rate responses, the TEs varied between 1 and 6 bpm, CVs between 0.7 and 4.8%, and ICCs between 0.73 and 0.97. The small ratio LOA revealed that any two YYIR1 performances in one week will not differ by more than 9 to 28% due to measurement error. In summary, the YYIR1 performance and the physiological responses have proven to be highly reliable in a sample of Belgian high-level youth soccer players, aged between 13 and 18 years. The demonstrated high level of intermittent endurance capacity in all age groups may be used for comparison of other prospective young soccer players.
Reliability Considerations for the Operation of Large Accelerator User Facilities
Willeke, F.J.
2016-01-01
The lecture provides an overview of considerations relevant for achieving highly reliable operation of accelerator based user facilities. The article starts with an overview of statistical reliability formalism which is followed by high reliability design considerations with examples. The article closes with operational aspects of high reliability such as preventive maintenance and spares inventory.
Leckelt, Marius; Wetzel, Eunike; Gerlach, Tanja M; Ackerman, Robert A; Miller, Joshua D; Chopik, William J; Penke, Lars; Geukes, Katharina; Küfner, Albrecht C P; Hutteman, Roos; Richter, David; Renner, Karl-Heinz; Allroggen, Marc; Brecheen, Courtney; Campbell, W Keith; Grossmann, Igor; Back, Mitja D
2018-01-01
Due to increased empirical interest in narcissism across the social sciences, there is a need for inventories that can be administered quickly while also reliably measuring both the agentic and antagonistic aspects of grandiose narcissism. In this study, we sought to validate the factor structure, provide representative descriptive data and reliability estimates, assess the reliability across the trait spectrum, and examine the nomological network of the short version of the Narcissistic Admiration and Rivalry Questionnaire (NARQ-S; Back et al., 2013). We used data from a large convenience sample (total N = 11,937) as well as data from a large representative sample (total N = 4,433) that included responses to other narcissism measures as well as related constructs, including the other Dark Triad traits, Big Five personality traits, and self-esteem. Confirmatory factor analysis and item response theory were used to validate the factor structure and estimate the reliability across the latent trait spectrum, respectively. Results suggest that the NARQ-S shows a robust factor structure and is a reliable and valid short measure of the agentic and antagonistic aspects of grandiose narcissism. We also discuss future directions and applications of the NARQ-S as a short and comprehensive measure of grandiose narcissism. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Validation and reliability of the Turkish Utian Quality-of-Life Scale in postmenopausal women.
Abay, Halime; Kaplan, Sena
2016-04-01
There are a limited number of menopause-specific quality-of-life scales for the Turkish population. This study was conducted to evaluate the validity and reliability of the Turkish Utian Quality-of-Life Scale in postmenopausal women. The study group was comprised of 250 postmenopausal women who applied to a training and research hospital's menopause clinic in Turkey. A survey form and the Turkish Utian quality-of-Life Scale were used to collect data, and the Turkish version of Short Form-36 was used to evaluate reliability with an equivalent form. Language-validity, content-validity, and construct-validity methods were used to assess the validity of the scale, and Cronbach's α coefficient calculation and the equivalent-form reliability methods were used to assess the reliability of the scale. The Turkish Utian Quality-of-Life Scale was determined to be a valid and reliable instrument for measuring the quality of life of postmenopausal women. Confirmatory factor analysis demonstrates that the instrument fits well with 23 items and a four-factor model. The Cronbach's α coefficient for the quality-of-life domains were as follows: 0.88 overall, 0.79 health, 0.78 emotional, 0.76 sexual, and 0.75 occupational. Reliability of the instrument was confirmed through significant correlations between scores on the Turkish version of the Utian Quality-of-Life Scale and the Turkish version of the Short Form-36 (r = 0.745, P measuring quality of life during menopause.
Optimized load sharing control by means of thermal reliability management
DEFF Research Database (Denmark)
Nesgaard, Carsten; Andersen, Michael Andreas E.
2004-01-01
time and system cost. However, due to non-ideal parts each converter unit deviates from the ideal case, which makes a power system comprised of parallel-connected converters a rather poor performing system. To account for the non-ideal parts some form of load sharing is needed, whereby it is ensured......With new applications for high-current low-output voltage power systems emerging nearly every day the need for new and cost-efficient power system designs is a matter of course. As output voltage levels continue to decrease an approach that seems more and more attractive is the implementation...... that each converter in the configuration delivers its share of the total output power. In other words parallel-operation of multiple converters is employed when specifications require a highly reliable system, designable within a very short time frame and at low costs. However, to make full use...
International Nuclear Information System (INIS)
Martin, David D.; Deusch, Dorothee; Schweizer, Roland; Binder, Gerhard; Ranke, Michael B.; Thodberg, Hans Henrik
2009-01-01
Bone age (BA) rating is time consuming and highly rater dependent. To adjust the fully automated BoneXpert method to agree with the manual Greulich and Pyle BA (GP BA) ratings of five raters and to validate the accuracy for short children. A total of 1,097 left hand radiographs from 188 children with short stature, including growth hormone deficiency (44%) and Turner syndrome (29%) were evaluated. BoneXpert rejected 14 of the 1,097 radiographs, and deviated by more than 1.9 years from the operator BA for 27 radiographs. These were rerated blindly by four operators. Of the 27 new ratings, 26 were within 1.9 years of the automatic BA values. The root mean square deviation between manual and automatic rating was 0.72 years (95% CI 0.69-0.75). BoneXpert's ability to process 99% of images automatically without errors, and to obtain good agreement with an operator suggests that the method is efficient and reliable for short children. (orig.)
Energy Technology Data Exchange (ETDEWEB)
Martin, David D.; Deusch, Dorothee; Schweizer, Roland; Binder, Gerhard; Ranke, Michael B. [University Children' s Hospital, Paediatric Endocrinology Section, Tuebingen (Germany); Thodberg, Hans Henrik [Visiana, Holte (Denmark)
2009-06-15
Bone age (BA) rating is time consuming and highly rater dependent. To adjust the fully automated BoneXpert method to agree with the manual Greulich and Pyle BA (GP BA) ratings of five raters and to validate the accuracy for short children. A total of 1,097 left hand radiographs from 188 children with short stature, including growth hormone deficiency (44%) and Turner syndrome (29%) were evaluated. BoneXpert rejected 14 of the 1,097 radiographs, and deviated by more than 1.9 years from the operator BA for 27 radiographs. These were rerated blindly by four operators. Of the 27 new ratings, 26 were within 1.9 years of the automatic BA values. The root mean square deviation between manual and automatic rating was 0.72 years (95% CI 0.69-0.75). BoneXpert's ability to process 99% of images automatically without errors, and to obtain good agreement with an operator suggests that the method is efficient and reliable for short children. (orig.)
Saito, Kotaro; Kihara, Mitsuru; Shimizu, Tomoya; Yoneda, Keisuke; Kurashima, Toshio
2015-06-01
We performed environmental and accelerated aging tests to ensure the long-term reliability of solid type refractive index matching material at a splice point. Stable optical characteristics were confirmed in environmental tests based on an IEC standard. In an accelerated aging test at 140 °C, which is very much higher than the specification test temperature, the index matching material itself and spliced fibers passing through it had steady optical characteristics. Then we performed an accelerated aging test on an index matching material attached to a built-in fiber before splicing it in the worst condition, which is different from the normal use configuration. As a result, we confirmed that the repeated insertion and removal of fiber for splicing resulted in failure. We consider that the repetition of adhesion between index matching material and fibers causes the splice to degrade. With this result, we used the Arrhenius model to estimate a median lifetime of about 68 years in a high temperature environment of 60 °C. Thus solid type index matching material at a splice point is highly reliable over long periods under normal conditions of use.
Test-retest reliability of the proposed DSM-5 eating disorder diagnostic criteria
Sysko, Robyn; Roberto, Christina A.; Barnes, Rachel D.; Grilo, Carlos M.; Attia, Evelyn; Walsh, B. Timothy
2012-01-01
The proposed DSM-5 classification scheme for eating disorders includes both major and minor changes to the existing DSM-IV diagnostic criteria. It is not known what effect these modifications will have on the ability to make reliable diagnoses. Two studies were conducted to evaluate the short-term test-retest reliability of the proposed DSM-5 eating disorder diagnoses: anorexia nervosa, bulimia nervosa, binge eating disorder, and feeding and eating conditions not elsewhere classified. Participants completed two independent telephone interviews with research assessors (n=70 Study 1; n=55 Study 2). Fair to substantial agreements (κ= 0.80 and 0.54) were observed across eating disorder diagnoses in Study 1 and Study 2, respectively. Acceptable rates of agreement were identified for the individual eating disorder diagnoses, including DSM-5 anorexia nervosa (κ’s of 0.81 to 0.97), bulimia nervosa (κ=0.84), binge eating disorder (κ’s of 0.75 and 0.61), and feeding and eating disorders not elsewhere classified (κ’s of 0.70 and 0.46). Further, improved short-term test-retest reliability was noted when using the DSM-5, in comparison to DSM-IV, criteria for binge eating disorder. Thus, these studies found that trained interviewers can reliably diagnose eating disorders using the proposed DSM-5 criteria; however, additional data from general practice settings and community samples are needed. PMID:22401974
DEFF Research Database (Denmark)
Zare, Mohammad Hadi; Mohamadian, Mustafa; Wang, Huai
2017-01-01
Microinverters usually connect a PV panel to a Single-phase power grid. In such system, the input power is constant while the output power oscillates twice the line frequency. Thus, the input and output power differences should be stored in a storage component, which is typically an electrolytic ...... irritation of two different places on the micro inverter lifetime is studied....... capacitor. However, electrolytic capacitors are usually blamed for their short lifetime. Recently, some active power decoupling methods are introduced in the literature which can takes advantage of high reliable film capacitors. However, some extra switches and diodes are added to the microinverter which...... can influence the microinverter lifetime. This paper investigates the microinverter reliability according to mission profile where it is installed. To get more accurate results, uncertainties in both lifetime model and manufacturing process are considered. The effect of ambient temperature and solar...
Short Pulse High Brightness X-ray Production with the PLEIADES Thomson Scattering Source
International Nuclear Information System (INIS)
Anderson, S.G.; Barty, C.P.J.; Betts, S.M.; Brown, W.J.; Crane, J.K.; Cross, R.R.; Fittinghoff, D.N.; Gibson, D.J.; Hartemann, F.V.; Kuba, J.; LaSage, G.P.; Rosenzweig, J.B.; Slaughter, D.R.; Springer, P.T.; Tremaine, A.M.
2003-01-01
We describe PLEIADES, a compact, tunable, high-brightness, ultra-short pulse, Thomson x-ray source. The peak brightness of the source is expected to exceed 10 20 photons/s/0.1% bandwidth/mm 2 /mrad 2 . Initial results are reported and compared to theoretical calculations
Simple and rapid preparation of [11C]DASB with high quality and reliability for routine applications
International Nuclear Information System (INIS)
Haeusler, D.; Mien, L.-K.; Nics, L.; Ungersboeck, J.; Philippe, C.; Lanzenberger, R.R.; Kletter, K.; Dudczak, R.; Mitterhauser, M.; Wadsak, W.
2009-01-01
[ 11 C]DASB combines all major prerequisites for a successful SERT-ligand, providing excellent biological properties and in-vivo behaviour. Thus, we aimed to establish a fully automated procedure for the synthesis and purification of [ 11 C]DASB with a high degree of reliability reducing the overall synthesis time while conserving high yields and purity. The optimized [ 11 C]DASB synthesis was applied in more than 60 applications with a very low failure rate (3.2%). We obtained yields up to 8.9 GBq (average 5.3±1.6 GBq). Radiochemical yields based on [ 11 C]CH 3 I, (corrected for decay) were 66.3±6.9% with a specific radioactivity (A s ) of 86.8±24.3 GBq/μmol (both at the end of synthesis, EOS). Time consumption was kept to a minimum, resulting in 43 min from end of bombardment to release of the product after quality control. Form our data, it is evident that the presented method can be implemented for routine preparations of [ 11 C]DASB with high reliability.
Anne E. Black; Brooke Baldauf. McBride
2013-01-01
In an effort to improve organizational outcomes, including safety, in wildland fire management, researchers and practitioners have turned to a domain of research on organizational performance known as High Reliability Organizing (HRO). The HRO paradigm emerged in the late 1980s in an effort to identify commonalities among organizations that function under hazardous...
Energy Technology Data Exchange (ETDEWEB)
Mitola, J. P.
2003-12-01
The effects of deregulation of the electric power industry on the reliability of the power grid in the United States are examined. Three major factors -- customer load, utility infrastructure, and demand response -- together are suggested as being most important; the ability of the industry to maintain the equilibrium among these three factors will determine the success or failure of deregulation. Each of these factors are examined in turn, followed by recommendations encouraging demand response or energy efficiency innovations, particularly new demand response technologies that are reliable, measurable, competitive to end-users, and fully dispatchable to utilities.
Reliability and availability of high power proton accelerators
International Nuclear Information System (INIS)
Cho, Y.
1999-01-01
It has become increasingly important to address the issues of operational reliability and availability of an accelerator complex early in its design and construction phases. In this context, reliability addresses the mean time between failures and the failure rate, and availability takes into account the failure rate as well as the length of time required to repair the failure. Methods to reduce failure rates include reduction of the number of components and over-design of certain key components. Reduction of the on-line repair time can be achieved by judiciously designed hardware, quick-service spare systems and redundancy. In addition, provisions for easy inspection and maintainability are important for both reduction of the failure rate as well as reduction of the time to repair. The radiation safety exposure principle of ALARA (as low as reasonably achievable) is easier to comply with when easy inspection capability and easy maintainability are incorporated into the design. Discussions of past experience in improving accelerator availability, some recent developments, and potential R and D items are presented. (author)
How high is visual short-term memory capacity for object layout?
Sanocki, Thomas; Sellers, Eric; Mittelstadt, Jeff; Sulman, Noah
2010-05-01
Previous research measuring visual short-term memory (VSTM) suggests that the capacity for representing the layout of objects is fairly high. In four experiments, we further explored the capacity of VSTM for layout of objects, using the change detection method. In Experiment 1, participants retained most of the elements in displays of 4 to 8 elements. In Experiments 2 and 3, with up to 20 elements, participants retained many of them, reaching a capacity of 13.4 stimulus elements. In Experiment 4, participants retained much of a complex naturalistic scene. In most cases, increasing display size caused only modest reductions in performance, consistent with the idea of configural, variable-resolution grouping. The results indicate that participants can retain a substantial amount of scene layout information (objects and locations) in short-term memory. We propose that this is a case of remote visual understanding, where observers' ability to integrate information from a scene is paramount.
Reliability of the NEO Five Factor Inventory short form for assessing personality after stroke.
Dwan, Toni; Ownsworth, Tamara; Donovan, Caroline; Lo, Ada Ho Yan
2017-07-01
It is well recognized that an individual's personality characteristics influence their psychological adjustment after stroke. However, there is a lack of research on the reliability of personality inventories for stroke. This study primarily aimed to evaluate the reliability of the Neuroticism, Extroversion, Openness to Experience (NEO)-Five Factor Inventory (NEO-FFI) for assessing pre-morbid personality and personality changes after stroke. Further aims were to investigate changes in personality during the hospital-to-home transition period and examine associations between personality and mood. Forty participants with stroke (52.5% male, M age=65.55 years) were recruited at time of hospital discharge and completed the NEO-FFI, Centre for Epidemiologic Studies - Depression and Geriatric Anxiety Inventory. Significant others completed an informant version of the NEO-FFI. Stroke participants were re-assessed on the NEO-FFI at 1-month and 4-months post-discharge. Forty matched controls also completed the NEO-FFI. Internal consistency was adequate for the NEO-FFI (α=0.57-0.86), although low for agreeableness. There was fair to excellent concordance between self-rated and informant versions of the NEO-FFI (ICC=0.58-0.78). Significant positive associations were found between neuroticism and mood (r=0.50-0.68), and significant negative associations were found between extraversion and mood (r=-0.33-0.36) and agreeableness and anxiety (r=-0.43). Self-ratings of stroke participants on the NEO-FFI at discharge did not significantly differ from matched controls. Extraversion levels significantly decreased, and agreeableness levels significantly increased between discharge and 1- and 4-months post-discharge. Overall, the results support the reliability of the NEO-FFI for assessing personality characteristics in the context of stroke.
International Nuclear Information System (INIS)
Mecham, W.J.; Seefeldt, W.B.; Steindler, M.J.
1976-08-01
The reliability of stainless steel type 304L canisters for the containment of solidified high-level radioactive wastes in the glass and calcine forms was studied. A reference system, drawn largely from information furnished by Battelle Northwest Laboratories and Atlantic Richfield Hanford Company is described. Operations include filling the canister with the appropriate waste form, interim storage at a reprocessing plant, shipment in water to a Retrievable Surface Storage Facility (RSSF), interim storage at the RSSF, and shipment to a final disposal facility. The properties of stainless steel type 304L, fission product oxides, calcine, and glass were reviewed, and mechanisms of corrosion were identified and studied. The modes of corrosion important for reliability were stress-corrosion cracking, internal pressurization of the canister by residual impurities present, intergranular attack at the waste-canister interface, and potential local effects due to migration of fission products. The key role of temperature control throughout canister lifetime is considered together with interactive effects. Methods of ameliorating adverse effects and ensuring high reliability are identified and described. Conclusions and recommendations are presented
Mungovan, Sean F; Peralta, Paula J; Gass, Gregory C; Scanlan, Aaron T
2018-04-12
To examine the test-retest reliability and criterion validity of a high-intensity, netball-specific fitness test. Repeated measures, within-subject design. Eighteen female netball players competing in an international competition completed a trial of the Net-Test, which consists of 14 timed netball-specific movements. Players also completed a series of netball-relevant criterion fitness tests. Ten players completed an additional Net-Test trial one week later to assess test-retest reliability using intraclass correlation coefficient (ICC), typical error of measurement (TEM), and coefficient of variation (CV). The typical error of estimate expressed as CV and Pearson correlations were calculated between each criterion test and Net-Test performance to assess criterion validity. Five movements during the Net-Test displayed moderate ICC (0.84-0.90) and two movements displayed high ICC (0.91-0.93). Seven movements and heart rate taken during the Net-Test held low CV (Test possessed low CV and significant (pTest possesses acceptable reliability for the assessment of netball fitness. Further, the high criterion validity for the Net-Test suggests a range of important netball-specific fitness elements are assessed in combination. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
The human factor in operation and maintenance of complex high-reliability systems
International Nuclear Information System (INIS)
Ryan, T.G.
1989-01-01
Human factors issues in probabilistic risk assessment (PRAs) of complex high-reliability systems are addressed. These PRAs influence system operation and technical support programs such as maintainability, test, and surveillance. Using the U.S. commercial nuclear power industry as the setting, the paper addresses the manner in which PRAs currently treat human performance, the state of quantification methods and source data for analyzing human performance, and the role of human factors specialist in the analysis. The paper concludes with a presentation of TALENT, an emerging concept for fully integrating broad-based human factors expertise into the PRA process, is presented. 47 refs
Vietnamese validation of the short version of Internet Addiction Test.
Tran, Bach Xuan; Mai, Hue Thi; Nguyen, Long Hoang; Nguyen, Cuong Tat; Latkin, Carl A; Zhang, Melvyn W B; Ho, Roger C M
2017-12-01
The main goal of the present study was to examine the psychometric properties of a Vietnamese version of the short-version of Internet Addiction Test (s-IAT) and to assess the relationship between s-IAT scores and demographics, health related qualify of life and perceived stress scores in young Vietnamese. The Vietnamese version of s-IAT was administered to a sample of 589 participants. Exploratory factor and reliability analyses were performed. Regression analysis was used to identify the associated factors. The two-factor model of Vietnamese version of s-IAT demonstrated good psychometric properties. The internal consistency of Factor 1 (loss of control/time management) was high (Cronbach's alpha = 0.82) and Factor 2 (craving/social problems) was satisfactory (Cronbach's alpha = 0.75). Findings indicated that 20.9% youths were addicted to the Internet. Regression analysis revealed significant associations between Internet addiction and having problems in self-care, lower quality of life and high perceived stress scores. The Vietnamese version of s-IAT is a valid and reliable instrument to assess IA in Vietnamese population. Due to the high prevalence of IA among Vietnamese youths, IA should be paid attention in future intervention programs. s-IAT can be a useful screening tool for IA to promptly inform and treat the IA among Vietnamese youths.
Electro-thermal modeling of high power IGBT module short-circuits with experimental validation
DEFF Research Database (Denmark)
Wu, Rui; Iannuzzo, Francesco; Wang, Huai
2015-01-01
A novel Insulated Gate Bipolar Transistor (IGBT) electro-thermal modeling approach involving PSpice and ANSYS/Icepak with both high accuracy and simulation speed has been presented to study short-circuit of a 1.7 kV/1 kA commercial IGBT module. The approach successfully predicts the current...
Construction of Short-length High-rates Ldpc Codes Using Difference Families
Deny Hamdani; Ery Safrianti
2007-01-01
Low-density parity-check (LDPC) code is linear-block error-correcting code defined by sparse parity-check matrix. It isdecoded using the massage-passing algorithm, and in many cases, capable of outperforming turbo code. This paperpresents a class of low-density parity-check (LDPC) codes showing good performance with low encoding complexity.The code is constructed using difference families from combinatorial design. The resulting code, which is designed tohave short code length and high code r...
Flexible multimode polymer waveguides for high-speed short-reach communication links
Bamiedakis, N.; Shi, F.; Chu, D.; Penty, R. V.; White, I. H.
2018-02-01
Multimode polymer waveguides have attracted great interest for use in high-speed short-reach communication links as they can be cost-effectively integrated onto standard PCBs using conventional methods of the electronics industry and provide low loss (30 GHz×m) interconnection. The formation of such waveguides on flexible substrates can further provide flexible low-weight low-thickness interconnects and offer additional freedom in the implementation of high-speed short-reach optical links. These attributes make these flexible waveguides particularly attractive for use in low-cost detachable chip-to-chip links and in environments where weight and shape conformity become important, such as in cars and aircraft. However, the highly-multimoded nature of these waveguides raises important questions about their performance under severe flex due to mode loss and mode coupling. In this work therefore, we investigate the loss, crosstalk and bandwidth performance of such waveguides under out-of plane bending and in-plane twisting under different launch conditions and carry out data transmission tests at 40 Gb/s on a 1 m long spiral flexible waveguide under flexure. Excellent optical transmission characteristics are obtained while robust loss, crosstalk and bandwidth performance are demonstrated under flexure. Error-free (BER<10-12) 40 Gb/s data transmission is achieved over the 1 m long spiral waveguide for a 180° bend with a 4 mm radius. The obtained results demonstrate the excellent optical and mechanical properties of this technology and highlight its potential for use in real-world systems.
Indrebø, Kirsten Lerum; Andersen, John Roger; Natvig, Gerd Karin
2014-01-01
The purpose of this study was to adapt the Ostomy Adjustment Scale to a Norwegian version and to assess its construct validity and 2 components of its reliability (internal consistency and test-retest reliability). One hundred fifty-eight of 217 patients (73%) with a colostomy, ileostomy, or urostomy participated in the study. Slightly more than half (56%) were men. Their mean age was 64 years (range, 26-91 years). All respondents had undergone ostomy surgery at least 3 months before participation in the study. The Ostomy Adjustment Scale was translated into Norwegian according to standard procedures for forward and backward translation. The questionnaire was sent to the participants via regular post. The Cronbach alpha and test-retest were computed to assess reliability. Construct validity was evaluated via correlations between each item and score sums; correlations were used to analyze relationships between the Ostomy Adjustment Scale and the 36-item Short Form Health Survey, the Quality of Life Scale, the Hospital Anxiety & Depression Scale, and the General Self-Efficacy Scale. The Cronbach alpha was 0.93, and test-retest reliability r was 0.69. The average correlation quotient item to sum score was 0.49 (range, 0.31-0.73). Results showed moderate negative correlations between the Ostomy Adjustment Scale and the Hospital Anxiety and Depression Scale (-0.37 and -0.40), and moderate positive correlations between the Ostomy Adjustment Scale and the 36-item Short Form Health Survey, the Quality of Life Scale, and the General Self-Efficacy Scale (0.30-0.45) with the exception of the pain domain in the Short Form 36 (0.28). Regression analysis showed linear associations between the Ostomy Adjustment Scale and sociodemographic and clinical variables with the exception of education. The Norwegian language version of the Ostomy Adjustment Scale was found to possess construct validity, along with internal consistency and test-retest reliability. The instrument is
Short Forms of Wechsler Scales Assessing the Intellectually Gifted Children Using Simulation Data
Directory of Open Access Journals (Sweden)
Alexandre Aubry
2018-05-01
Full Text Available Intellectual giftedness is usually defined in terms of having a very high Intellectual Quotient (IQ. The intellectual capacity is assessed by a standardized test such as the Wechsler Intelligence Scale for Children (WISC. However, the identification of intellectually gifted children (IGC often remains time-consuming. A short-form WISC can be used as a screening instrument. The practitioners and researchers in this field can then make a more in-depth evaluation of the IGC's cognitive and socioemotional characteristics if needed. The aim of our study is thus to determine the best short tests, in terms of their psychometric qualities, for the identification of IGC. The current study is composed of three-step analyses. Firstly, we created nine IQs short forms (IQSF with 2-subtests, and nine IQSF with 4-subtests from the WISC-IV (Wechsler, 2005. Secondly, we estimated psychometric parameters (i.e., reliability and validity from empirical and simulated dataset with WISC-IV. The difference in the estimation of psychometric qualities of each IQSF from the simulated data is very close to those derived from empirical data. We thus selected the three best IQSF based on these psychometrics parameters estimated from simulated datasets. For each selected short form of the WISC-IV, we estimated the screening quality in our sample of IGC. Thirdly, we created IQSF with 2- and 4-subtests from the WISC-V (Wechsler, 2016 with simulated dataset. We then highlighted the three best short forms of WISC-V based on the estimated psychometric parameters. The results are interpreted in terms of validity, reliability and screening quality of IGC. In spite of the important changes in the WISC-V, our findings show that the 2-subtest form, Similitaries + Matrix Reasoning, and 4-subtest form, Similitaries + Vocabulary + Matrix Reasoning + Block Design, are the most efficient to identify the IGC at the two recent versions of Wechsler scales. Finally, we discuss the advantages
Implementing Molecular Dynamics for Hybrid High Performance Computers - 1. Short Range Forces
International Nuclear Information System (INIS)
Brown, W. Michael; Wang, Peng; Plimpton, Steven J.; Tharrington, Arnold N.
2011-01-01
The use of accelerators such as general-purpose graphics processing units (GPGPUs) have become popular in scientific computing applications due to their low cost, impressive floating-point capabilities, high memory bandwidth, and low electrical power requirements. Hybrid high performance computers, machines with more than one type of floating-point processor, are now becoming more prevalent due to these advantages. In this work, we discuss several important issues in porting a large molecular dynamics code for use on parallel hybrid machines - (1) choosing a hybrid parallel decomposition that works on central processing units (CPUs) with distributed memory and accelerator cores with shared memory, (2) minimizing the amount of code that must be ported for efficient acceleration, (3) utilizing the available processing power from both many-core CPUs and accelerators, and (4) choosing a programming model for acceleration. We present our solution to each of these issues for short-range force calculation in the molecular dynamics package LAMMPS. We describe algorithms for efficient short range force calculation on hybrid high performance machines. We describe a new approach for dynamic load balancing of work between CPU and accelerator cores. We describe the Geryon library that allows a single code to compile with both CUDA and OpenCL for use on a variety of accelerators. Finally, we present results on a parallel test cluster containing 32 Fermi GPGPUs and 180 CPU cores.
International Nuclear Information System (INIS)
Eisfeld, F.
1987-01-01
The knowledge about the penetration of diesel injection jets, particularly about the flow within the short behind the nozzle, and the arising of droplets from an injection jet is very limited. Experimental investigations are required to describe the process of penetration and spreading of the jet. The research method requires high speed cinematography and short time holography. Problems in the investigation method are described
MOSFET-based high voltage short pulse generator for ultrasonic transducer excitation
Hidayat, Darmawan; Setianto, Syafei, Nendi Suhendi; Wibawa, Bambang Mukti
2018-02-01
This paper presents the generation of a high-voltage short pulse for the excitation of high frequency ultrasonic transducers. This is highly required in the purpose of various ultrasonic-based evaluations, particularly when high resolution measurement is necessary. A high voltage (+760 V) DC voltage source was pulsated by an ultrafast switching MOSFET which was driven by a pulse generator circuit consisting of an astable multivibrator, a one-shot multivibrator with Schmitt trigger input and a high current MOSFET driver. The generated pulses excited a 200-kHz and a 1-MHz ultrasonic transducers and tested in the transmission mode propagation to evaluate the performances of the generated pulse. The test results showed the generator were able to produce negative spike pulses up to -760 V voltage with the shortest time-width of 107.1 nanosecond. The transmission-received ultrasonic waves show frequency oscillation at 200 and 961 kHz and their amplitudes varied with the voltage of excitation pulse. These results conclude that the developed pulse generator is applicable to excite transducer for the generation of high frequency ultrasonic waves.
Smith, Stacey L.; Vannest, Kimberly J.; Davis, John L.
2011-01-01
The reliability of data is a critical issue in decision-making for practitioners in the school. Percent Agreement and Cohen's kappa are the two most widely reported indices of inter-rater reliability, however, a recent Monte Carlo study on the reliability of multi-category scales found other indices to be more trustworthy given the type of data…
Data-driven forecasting of high-dimensional chaotic systems with long short-term memory networks.
Vlachas, Pantelis R; Byeon, Wonmin; Wan, Zhong Y; Sapsis, Themistoklis P; Koumoutsakos, Petros
2018-05-01
We introduce a data-driven forecasting method for high-dimensional chaotic systems using long short-term memory (LSTM) recurrent neural networks. The proposed LSTM neural networks perform inference of high-dimensional dynamical systems in their reduced order space and are shown to be an effective set of nonlinear approximators of their attractor. We demonstrate the forecasting performance of the LSTM and compare it with Gaussian processes (GPs) in time series obtained from the Lorenz 96 system, the Kuramoto-Sivashinsky equation and a prototype climate model. The LSTM networks outperform the GPs in short-term forecasting accuracy in all applications considered. A hybrid architecture, extending the LSTM with a mean stochastic model (MSM-LSTM), is proposed to ensure convergence to the invariant measure. This novel hybrid method is fully data-driven and extends the forecasting capabilities of LSTM networks.
Rangel-Abundis, Alberto
2006-01-01
Shunt and short circuit are antonyms. In French, the term shunt has been adopted to denote the alternative pathway of blood flow. However, in French, as well as in Spanish, the word short circuit (court-circuit and cortocircuito) is synonymous with shunt, giving rise to a linguistic and scientific inconsistency. Scientific because shunt and short circuit made reference to a phenomenon that occurs in the field of the physics. Because shunt and short circuit are antonyms, it is necessary to clarify that shunt is an alternative pathway of flow from a net of high resistance to a net of low resistance, maintaining the stream. Short circuit is the interruption of the flow, because a high resistance impeaches the flood. This concept is applied to electrical and cardiovascular physiology, as well as to the metabolic pathways.
Enhancement of High-Intensity Focused Ultrasound Heating by Short-Pulse Generated Cavitation
Directory of Open Access Journals (Sweden)
Shin Yoshizawa
2017-03-01
Full Text Available A target tissue can be thermally coagulated in high-intensity focused ultrasound (HIFU treatment noninvasively. HIFU thermal treatments have been clinically applied to various solid tumors. One of the problems in HIFU treatments is a long treatment time. Acoustically driven microbubbles can accelerate the ultrasonic heating, resulting in the significant reduction of the treatment time. In this paper, a method named “trigger HIFU exposure” which employs cavitation microbubbles is introduced and its results are reviewed. A trigger HIFU sequence consists of high-intensity short pulses followed by moderate-intensity long bursts. Cavitation bubbles induced in a multiple focal regions by rapidly scanning the focus of high-intensity pulses enhanced the temperature increase significantly and produced a large coagulation region with high efficiency.
Improving the Test-Retest Reliability of Resting State fMRI by Removing the Impact of Sleep
Directory of Open Access Journals (Sweden)
Jiahui Wang
2017-05-01
Full Text Available Resting state functional magnetic resonance imaging (rs-fMRI provides a powerful tool to examine large-scale neural networks in the human brain and their disturbances in neuropsychiatric disorders. Thanks to its low demand and high tolerance, resting state paradigms can be easily acquired from clinical population. However, due to the unconstrained nature, resting state paradigm is associated with excessive head movement and proneness to sleep. Consequently, the test-retest reliability of rs-fMRI measures is moderate at best, falling short of widespread use in the clinic. Here, we characterized the effect of sleep on the test-retest reliability of rs-fMRI. Using measures of heart rate variability (HRV derived from simultaneous electrocardiogram (ECG recording, we identified portions of fMRI data when subjects were more alert or sleepy, and examined their effects on the test-retest reliability of functional connectivity measures. When volumes of sleep were excluded, the reliability of rs-fMRI is significantly improved, and the improvement appears to be general across brain networks. The amount of improvement is robust with the removal of as much as 60% volumes of sleepiness. Therefore, test-retest reliability of rs-fMRI is affected by sleep and could be improved by excluding volumes of sleepiness as indexed by HRV. Our results suggest a novel and practical method to improve test-retest reliability of rs-fMRI measures.
Systems reliability/structural reliability
International Nuclear Information System (INIS)
Green, A.E.
1980-01-01
The question of reliability technology using quantified techniques is considered for systems and structures. Systems reliability analysis has progressed to a viable and proven methodology whereas this has yet to be fully achieved for large scale structures. Structural loading variants over the half-time of the plant are considered to be more difficult to analyse than for systems, even though a relatively crude model may be a necessary starting point. Various reliability characteristics and environmental conditions are considered which enter this problem. The rare event situation is briefly mentioned together with aspects of proof testing and normal and upset loading conditions. (orig.)
Jiang, Changlong; Ma, Cheng; He, Ning; Zhang, Xugang; Wang, Chongyang; Jia, Huibo
2002-12-01
In many real-time fields the sustained high-speed data recording system is required. This paper proposes a high-speed and sustained data recording system based on the complex-RAID 3+0. The system consists of Array Controller Module (ACM), String Controller Module (SCM) and Main Controller Module (MCM). ACM implemented by an FPGA chip is used to split the high-speed incoming data stream into several lower-speed streams and generate one parity code stream synchronously. It also can inversely recover the original data stream while reading. SCMs record lower-speed streams from the ACM into the SCSI disk drivers. In the SCM, the dual-page buffer technology is adopted to implement speed-matching function and satisfy the need of sustainable recording. MCM monitors the whole system, controls ACM and SCMs to realize the data stripping, reconstruction, and recovery functions. The method of how to determine the system scale is presented. At the end, two new ways Floating Parity Group (FPG) and full 2D-Parity Group (full 2D-PG) are proposed to improve the system reliability and compared with the Traditional Parity Group (TPG). This recording system can be used conveniently in many areas of data recording, storing, playback and remote backup with its high-reliability.
Energy Technology Data Exchange (ETDEWEB)
DeVoto, Douglas J. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)
2017-10-19
As maximum device temperatures approach 200 °Celsius, continuous operation, sintered silver materials promise to maintain bonds at these high temperatures without excessive degradation rates. A detailed characterization of the thermal performance and reliability of sintered silver materials and processes has been initiated for the next year. Future steps in crack modeling include efforts to simulate crack propagation directly using the extended finite element method (X-FEM), a numerical technique that uses the partition of unity method for modeling discontinuities such as cracks in a system.
International Nuclear Information System (INIS)
Lee, Sang Yong
1992-07-01
This book is about reliability engineering, which describes definition and importance of reliability, development of reliability engineering, failure rate and failure probability density function about types of it, CFR and index distribution, IFR and normal distribution and Weibull distribution, maintainability and movability, reliability test and reliability assumption in index distribution type, normal distribution type and Weibull distribution type, reliability sampling test, reliability of system, design of reliability and functionality failure analysis by FTA.
Analysis of short-chain acids from anaerobic bacteria by high-performance liquid chromatography.
Guerrant, G O; Lambert, M A; Moss, C W
1982-01-01
A standard mixture of 25 short-chain fatty acids was resolved by high-performance liquid chromatography, using an Aminex HPX-87 column. The acids produced in culture media by anaerobic bacteria were analyzed by high-performance liquid chromatography after extraction with ether and reextraction into a small volume of 0.1 N NaOH. The presence of fumaric acid in culture extracts of Peptostreptococcus anaerobius was confirmed by gas chromatography-mass spectrometry analysis of the trapped eluent ...
The Effects of Music on High-intensity Short-term Exercise in Well Trained Athletes.
Jarraya, Mohamed; Chtourou, Hamdi; Aloui, Asma; Hammouda, Omar; Chamari, Karim; Chaouachi, Anis; Souissi, Nizar
2012-12-01
The purpose of this investigation was to assess the effects of listening to music during warm-up on short-term supramaximal performances during the 30-s Wingate test in highly trained athletes. Twelve young male athletes (20.6±1.8 yrs, 177±4.4 cm and 72.3±5.3 kg) underwent two Wingate tests in separate sessions with a recovery period of 48 h in-between, either after a 10 min of warm-up with (MWU) or without (NMWU) music. High tempo music (>120 to 140bpm) was selected for the study. Heart rate (HR) and rate of perceived exertion (RPE) were recorded after the warm-up (for HR = average of warm-up) and immediately after the Wingate test. HR, RPE and the fatigue index during the Wingate test are not affected by the incorporation of music during warm-up. However, power output (P(peak) and P(mean)) was significantly higher after MWU than NMWU (Peffect of music during warm-up on short-term supramaximal performances. As it's a legal method and an additional aid, music may be used during warm-up before performing activities requiring powerful lower limbs' muscles contractions during short-term supramaximal exercises.
Highly reliable computer network for real time system
International Nuclear Information System (INIS)
Mohammed, F.A.; Omar, A.A.; Ayad, N.M.A.; Madkour, M.A.I.; Ibrahim, M.K.
1988-01-01
Many of computer networks have been studied different trends regarding the network architecture and the various protocols that govern data transfers and guarantee a reliable communication among all a hierarchical network structure has been proposed to provide a simple and inexpensive way for the realization of a reliable real-time computer network. In such architecture all computers in the same level are connected to a common serial channel through intelligent nodes that collectively control data transfers over the serial channel. This level of computer network can be considered as a local area computer network (LACN) that can be used in nuclear power plant control system since it has geographically dispersed subsystems. network expansion would be straight the common channel for each added computer (HOST). All the nodes are designed around a microprocessor chip to provide the required intelligence. The node can be divided into two sections namely a common section that interfaces with serial data channel and a private section to interface with the host computer. This part would naturally tend to have some variations in the hardware details to match the requirements of individual host computers. fig 7
Reliability on the move: safety and reliability in transportation
International Nuclear Information System (INIS)
Guy, G.B.
1989-01-01
The development of transportation has been a significant factor in the development of civilisation as a whole. Our technical ability to move people and goods now seems virtually limitless when one considers for example the achievements of the various space programmes. Yet our current achievements rely heavily on high standards of safety and reliability from equipment and the human component of transportation systems. Recent failures have highlighted our dependence on equipment and human reliability. This book represents the proceedings of the 1989 Safety and Reliability Society symposium held at Bath on 11-12 October 1989. The structure of the book follows the structure of the symposium itself and the papers selected represent current thinking the the wide field of transportation, and the areas of rail (6 papers, three on railway signalling), air including space (two papers), road (one paper), road and rail (two papers) and sea (three papers) are covered. There are four papers concerned with general transport issues. Three papers concerned with the transport of radioactive materials are indexed separately. (author)
Flow characteristics of a pilot-scale high temperature, short time pasteurizer.
Tomasula, P M; Kozempel, M F
2004-09-01
In this study, we present a method for determining the fastest moving particle (FMP) and residence time distribution (RTD) in a pilot-scale high temperature, short time (HTST) pasteurizer to ensure that laboratory or pilot-scale HTST apparatus meets the Pasteurized Milk Ordinance standards for pasteurization of milk and can be used for obtaining thermal inactivation data. The overall dimensions of the plate in the pasteurizer were 75 x 115 mm, with a thickness of 0.5 mm and effective diameter of 3.0 mm. The pasteurizer was equipped with nominal 21.5- and 52.2-s hold tubes, and flow capacity was variable from 0 to 20 L/h. Tracer studies were used to determine FMP times and RTD data to establish flow characteristics. Using brine milk as tracer, the FMP time for the short holding section was 18.6 s and for the long holding section was 36 s at 72 degrees C, compared with the nominal times of 21.5 and 52.2 s, respectively. The RTD study indicates that the short hold section was 45% back mixed and 55% plug flow for whole milk at 72 degrees C. The long hold section was 91% plug and 9% back mixed for whole milk at 72 degrees C. This study demonstrates that continuous laboratory and pilot-scale pasteurizers may be used to study inactivation of microorganisms only if the flow conditions in the holding tube are established for comparison with commercial HTST systems.
DUAL-PROCESS, a highly reliable process control system
International Nuclear Information System (INIS)
Buerger, L.; Gossanyi, A.; Parkanyi, T.; Szabo, G.; Vegh, E.
1983-02-01
A multiprocessor process control system is described. During its development the reliability was the most important aspect because it is used in the computerized control of a 5 MW research reactor. DUAL-PROCESS is fully compatible with the earlier single processor control system PROCESS-24K. The paper deals in detail with the communication, synchronization, error detection and error recovery problems of the operating system. (author)
Regulatory and personality predictors of the reliability of professional actions
Directory of Open Access Journals (Sweden)
Morosanova V.I.
2017-12-01
Full Text Available Background. The present research is carried out in the context of the conscious self-regulation of professional activity. Objective. It investigates the regulatory and personality predictors of reliability in rescue operations under stressful conditions. Design. The research sample includes 87 rescuers (72 men and 15 women aged from 25 to 50 years. Respondents were asked to complete the Morosanova’s Self-Regulation Profile Questionnaire – SRPQM, the Eysenck Personality Profile - Short (EPP-S, and the expert questionnaire “Professional Reliability of Rescue Operation” designed for this particular study. Results. On the basis of a correlation analysis, the structural model of the predictors of action reliability was constructed using the maximum likelihood method. Consistency indices showed a good agreement between the model and empirical data. The model contains three latent factors: “Self-regulation”, “Neuroticism” and “Reliability of actions”. As the model displays, the “Self-regulation” factor is a significant predictor of professional action reliability. There are two indicator variables for the factor “Self-regulation”: the self-regulation reliability considered as its stability in the stressful situations, and the rescuers’ levels of development of professionally critical regulatory features - modeling of conditions significant for the achievement of goals and the programming of actions. The study results also show that personality dispositions (by Eysenck have only indirect influence on action reliability. As the structural model reveals, the conscious self-regulation is a mediator in the relationship of neuroticism traits and action reliability. Conclusion. The conscious self-regulation is a significant predictor of professional action reliability under stressful conditions. It is also the mediator of the effects of personality dispositions on the reliability of action.
Vázquez Peña, Fernando; Harzheim, Erno; Terrasa, Sergio; Berra, Silvina
2017-02-01
To validate the Brazilian short version of the PCAT for adult patients in Spanish. Analysis of secondary data from studies made to validate the extended version of the PCAT questionnaire. City of Córdoba, Argentina. Primary health care. The sample consisted of 46% of parents, whose children were enrolled in secondary education in three institutes in the city of Cordoba, and the remaining 54% were adult users of the National University of Cordoba Health Insurance. Pearson's correlation coefficient comparing the extended and short versions. Goodness-of-fit indices in confirmatory factor analysis, composite reliability, average variance extracted, and Cronbach's alpha values, in order to assess the construct validity and the reliability of the short version. The values of Pearson's correlation coefficient between this short version and the long version were high .818 (Pmedia extracted: .3306, since 3 variables had weak factorials loads. The Cronbach's alpha was acceptable (.85). The short version of the PCAT-users developed in Brazil showed an acceptable psychometric performance in Spanish as a quick assessment tool, in a comparative study with the extended version. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Condon, David; Revelle, William
2017-01-01
Separating the signal in a test from the irrelevant noise is a challenge for all measurement. Low test reliability limits test validity, attenuates important relationships, and can lead to regression artifacts. Multiple approaches to the assessment and improvement of reliability are discussed. The advantages and disadvantages of several different approaches to reliability are considered. Practical advice on how to assess reliability using open source software is provided.
On the reliability of spacecraft swarms
Engelen, S.; Gill, E.K.A.; Verhoeven, C.J.M.
2012-01-01
Satellite swarms, consisting of a large number of identical, miniaturized and simple satellites, are claimed to provide an implementation for specific space missions which require high reliability. However, a consistent model of how reliability and availability on mission level is linked to cost-
A review of the reliability analysis of LPRS including the components repairs
International Nuclear Information System (INIS)
Oliveira, L.F.S. de; Fleming, P.V.; Frutuoso e Melo, P.F.F.; Tayt-Sohn, L.C.
1983-01-01
The reliability analysis of low pressure recirculation system in its long-term recicurlation phase before 24hs is presented. The possibility of repairing the components out of the containment is included. A general revision of analysis of the short-term recirculation phase is done. (author) [pt
The Reliability and Validity of the Coopersmith Self-Esteem Inventory-Form B.
Chiu, Lian-Hwang
1985-01-01
The purpose of this study was to determine the test-retest reliability and concurrent validity of the short form (Form B) of the Coopersmith Self-Esteem Inventory. Criterion measures for validity included: (1) sociometric measures; (2) teacher's popularity ranking; and, (3) self-esteem rating. (Author/LMO)
Utility and reliability of non-invasive muscle function tests in high-fat-fed mice.
Martinez-Huenchullan, Sergio F; McLennan, Susan V; Ban, Linda A; Morsch, Marco; Twigg, Stephen M; Tam, Charmaine S
2017-07-01
What is the central question of this study? Non-invasive muscle function tests have not been validated for use in the study of muscle performance in high-fat-fed mice. What is the main finding and its importance? This study shows that grip strength, hang wire and four-limb hanging tests are able to discriminate the muscle performance between chow-fed and high-fat-fed mice at different time points, with grip strength being reliable after 5, 10 and 20 weeks of dietary intervention. Non-invasive tests are commonly used for assessing muscle function in animal models. The value of these tests in obesity, a condition where muscle strength is reduced, is unclear. We investigated the utility of three non-invasive muscle function tests, namely grip strength (GS), hang wire (HW) and four-limb hanging (FLH), in C57BL/6 mice fed chow (chow group, n = 48) or a high-fat diet (HFD group, n = 48) for 20 weeks. Muscle function tests were performed at 5, 10 and 20 weeks. After 10 and 20 weeks, HFD mice had significantly reduced GS (in newtons; mean ± SD: 10 weeks chow, 1.89 ± 0.1 and HFD, 1.79 ± 0.1; 20 weeks chow, 1.99 ± 0.1 and HFD, 1.75 ± 0.1), FLH [in seconds per gram body weight; median (interquartile range): 10 weeks chow, 2552 (1337-4964) and HFD, 1230 (749-1994); 20 weeks chow, 2048 (765-3864) and HFD, 1036 (717-1855)] and HW reaches [n; median (interquartile range): 10 weeks chow, 4 (2-5) and HFD, 2 (1-3); 20 weeks chow, 3 (1-5) and HFD, 1 (0-2)] and higher falls [n; median (interquartile range): 10 weeks chow, 0 (0-2) and HFD, 3 (1-7); 20 weeks chow, 1 (0-4) and HFD, 8 (5-10)]. Grip strength was reliable in both dietary groups [intraclass correlation coefficient (ICC) = 0.5-0.8; P tests are valuable and reliable tools for assessment of muscle strength and function in high-fat-fed mice. © 2017 The Authors. Experimental Physiology © 2017 The Physiological Society.
International Nuclear Information System (INIS)
Downer, M.C.
1996-01-01
The Laser Sources working group concerned itself with recent advances in and future requirements for the development of laser sources relevant to high-energy physics (HEP) colliders, small scale accelerators, and the generation of short wave-length radiation. We heavily emphasized pulsed terawatt peak power laser sources for several reasons. First, their development over the past five years has been rapid and multi-faceted, and has made relativistic light intensity available to the advanced accelerator community, as well as the wider physics community, for the first time. Secondly, they have strongly impacted plasma-based accelerator research over the past two years, producing the first experimental demonstrations of the laser wakefield accelerator (LWFA) in both its resonantly-driven and self-modulated forms. Thirdly, their average power and wall-plug efficiency currently fall well short of projected requirements for future accelerators and other high average power applications, but show considerable promise for improving substantially over the next few years. A review of this rapidly emerging laser technology in the context of advanced accelerator research is therefore timely
High intensive short laser pulse interaction with submicron clusters media
International Nuclear Information System (INIS)
Faenov, A. Ya
2008-01-01
The interaction of short intense laser pulses with structured targets, such as clusters, exhibits unique features, stemming from the enhanced absorption of the incident laser light compared to solid targets. Due to the increased absorption, these targets are heated significantly, leading to enhanced emission of x rays in the keV range and generation of electrons and multiple charged ions with kinetic energies from tens of keV to tens of MeV. Possible applications of these targets can be an electron/ion source for a table top accelerator, a neutron source for a material damage study, or an x ray source for microscopy or lithography. The overview of recent results, obtained by the high intensive short laser pulse interaction with different submicron clusters media will be presented. High resolution K and L shell spectra of plasma generated by superintense laser irradiation of micron sized Ar, Kr and Xe clusters have been measured with intensity 10"17"-10"19"W/cm"2"and a pulse duration of 30-1000fs. It is found that hot electrons produced by high contrast laser pulses allow the isochoric heating of clusters and shift the ion balance toward the higher charge states, which enhances both the X ray line yield and the ion kinetic energy. Irradiation of clusters, produced from such gas mixture, by a fs Ti:Sa laser pulses allows to enhance the soft X ray radiation of Heβ(665.7eV)and Lyα(653.7eV)of Oxygen in 2-8 times compare with the case of using as targets pure CO"2"or N"2"O clusters and reach values 2.8x10"10"(∼3μJ)and 2.7x10"10"(∼2.9μJ)ph/(sr·pulse), respectively. Nanostructure conventional soft X ray images of 100nm thick Mo and Zr foils in a wide field of view (cm"2"scale)with high spatial resolution (700nm)are obtained using the LiF crystals as soft X ray imaging detectors. When the target used for the ion acceleration studies consists of solid density clusters embedded into the background gas, its irradiation by high intensity laser light makes the target
Dutta, Sunil
1999-01-01
The importance of high fracture toughness and reliability in Si3N4, and SiC-based structural ceramics and ceramic matrix composites is reviewed. The potential of these ceramics and ceramic matrix composites for high temperature applications in defense and aerospace applications such as gas turbine engines, radomes, and other energy conversion hardware have been well recognized. Numerous investigations were pursued to improve fracture toughness and reliability by incorporating various reinforcements such as particulate-, whisker-, and continuous fiber into Si3N4 and SiC matrices. All toughening mechanisms, e.g. crack deflection, crack branching, crack bridging, etc., essentially redistribute stresses at the crack tip and increase the energy needed to propagate a crack through the composite material, thereby resulting in improved fracture toughness and reliability. Because of flaw insensitivity, continuous fiber reinforced ceramic composite (CFCC) was found to have the highest potential for higher operating temperature and longer service conditions. However, the ceramic fibers should display sufficient high temperature strength and creep resistance at service temperatures above 1000 'C. The greatest challenge to date is the development of high quality ceramic fibers with associate coatings able to maintain their high strength in oxidizing environment at high temperature. In the area of processing, critical issues are, preparation of optimum matrix precursors, precursor infiltration into fiber array, and matrix densification at a temperature, where grain crystallization and fiber degradation do not occur. A broad scope of effort is required for improved processing and properties with a better understanding of all candidate composite systems.
Short-term effects of implemented high intensity shoulder elevation during computer work
DEFF Research Database (Denmark)
Larsen, Mette K.; Samani, Afshin; Madeleine, Pascal
2009-01-01
computer work to prevent neck-shoulder pain may be possible without affecting the working routines. However, the unexpected reduction in clavicular trapezius rest during a pause with preceding high intensity contraction requires further investigation before high intensity shoulder elevations can......BACKGROUND: Work-site strength training sessions are shown effective to prevent and reduce neck-shoulder pain in computer workers, but difficult to integrate in normal working routines. A solution for avoiding neck-shoulder pain during computer work may be to implement high intensity voluntary...... contractions during the computer work. However, it is unknown how this may influence productivity, rate of perceived exertion (RPE) as well as activity and rest of neck-shoulder muscles during computer work. The aim of this study was to investigate short-term effects of a high intensity contraction...
Energy Technology Data Exchange (ETDEWEB)
Haeusler, D.; Mien, L.-K. [Department of Nuclear Medicine, PET, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Department of Pharmaceutical Technology and Biopharmaceutics, University of Vienna, A-1090 Vienna (Austria); Nics, L. [Department of Nuclear Medicine, PET, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Department of Nutritional Sciences, University of Vienna, A-1090 Vienna (Austria); Ungersboeck, J. [Department of Nuclear Medicine, PET, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Department of Inorganic Chemistry, University of Vienna, A-1090 Vienna (Austria); Philippe, C. [Department of Nuclear Medicine, PET, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Department of Pharmaceutical Technology and Biopharmaceutics, University of Vienna, A-1090 Vienna (Austria); Lanzenberger, R.R. [Department of Psychiatry and Psychotherapy, Medical University of Vienna, A-1090 Vienna (Austria); Kletter, K.; Dudczak, R. [Department of Nuclear Medicine, PET, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Mitterhauser, M. [Department of Nuclear Medicine, PET, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Department of Pharmaceutical Technology and Biopharmaceutics, University of Vienna, A-1090 Vienna (Austria); Hospital Pharmacy of the General Hospital of Vienna, A-1090 Vienna (Austria); Wadsak, W. [Department of Nuclear Medicine, PET, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Department of Inorganic Chemistry, University of Vienna, A-1090 Vienna (Austria)], E-mail: wolfgang.wadsak@meduniwien.ac.at
2009-09-15
[{sup 11}C]DASB combines all major prerequisites for a successful SERT-ligand, providing excellent biological properties and in-vivo behaviour. Thus, we aimed to establish a fully automated procedure for the synthesis and purification of [{sup 11}C]DASB with a high degree of reliability reducing the overall synthesis time while conserving high yields and purity. The optimized [{sup 11}C]DASB synthesis was applied in more than 60 applications with a very low failure rate (3.2%). We obtained yields up to 8.9 GBq (average 5.3{+-}1.6 GBq). Radiochemical yields based on [{sup 11}C]CH{sub 3}I, (corrected for decay) were 66.3{+-}6.9% with a specific radioactivity (A{sub s}) of 86.8{+-}24.3 GBq/{mu}mol (both at the end of synthesis, EOS). Time consumption was kept to a minimum, resulting in 43 min from end of bombardment to release of the product after quality control. Form our data, it is evident that the presented method can be implemented for routine preparations of [{sup 11}C]DASB with high reliability.
QUASI-PERIODIC OSCILLATIONS AND BROADBAND VARIABILITY IN SHORT MAGNETAR BURSTS
Energy Technology Data Exchange (ETDEWEB)
Huppenkothen, Daniela; Watts, Anna L.; Uttley, Phil; Van der Horst, Alexander J.; Van der Klis, Michiel [Astronomical Institute ' ' Anton Pannekoek' ' , University of Amsterdam, Postbus 94249, 1090-GE Amsterdam (Netherlands); Kouveliotou, Chryssa [Office of Science and Technology, ZP12, NASA Marshall Space Flight Center, Huntsville, AL 35812 (United States); Goegues, Ersin [Sabanc Latin-Small-Letter-Dotless-I University, Orhanl Latin-Small-Letter-Dotless-I -Tuzla, Istanbul 34956 (Turkey); Granot, Jonathan [The Open University of Israel, 1 University Road, P.O. Box 808, Ra' anana 43537 (Israel); Vaughan, Simon [X-Ray and Observational Astronomy Group, University of Leicester, Leicester LE1 7RH (United Kingdom); Finger, Mark H., E-mail: D.Huppenkothen@uva.nl [Universities Space Research Association, Huntsville, AL 35805 (United States)
2013-05-01
The discovery of quasi-periodic oscillations (QPOs) in magnetar giant flares has opened up prospects for neutron star asteroseismology. However, with only three giant flares ever recorded, and only two with data of sufficient quality to search for QPOs, such analysis is seriously data limited. We set out a procedure for doing QPO searches in the far more numerous, short, less energetic magnetar bursts. The short, transient nature of these bursts requires the implementation of sophisticated statistical techniques to make reliable inferences. Using Bayesian statistics, we model the periodogram as a combination of red noise at low frequencies and white noise at high frequencies, which we show is a conservative approach to the problem. We use empirical models to make inferences about the potential signature of periodic and QPOs at these frequencies. We compare our method with previously used techniques and find that although it is on the whole more conservative, it is also more reliable in ruling out false positives. We illustrate our Bayesian method by applying it to a sample of 27 bursts from the magnetar SGR J0501+4516 observed by the Fermi Gamma-ray Burst Monitor, and we find no evidence for the presence of QPOs in any of the bursts in the unbinned spectra, but do find a candidate detection in the binned spectra of one burst. However, whether this signal is due to a genuine quasi-periodic process, or can be attributed to unmodeled effects in the noise is at this point a matter of interpretation.
Developing MESA : an accelerated reliability test
Baskoro, G.; Rouvroye, J.L.; Bacher, W.; Brombacher, A.C.
2003-01-01
This paper describes the on-going research on an accelerated reliability test strategy called MESA (Multiple Environment Stress Analysis) intended to find in a fast and efficient manner (potential) reliability problems during the design phase of high volume consumer products. This test has shown
Huang, Y.; Kim, H. J.; McCracken, M.; Viswanathan, G.; Pon, F.; Mayer, M.; Zhou, Y. N.
2011-06-01
A 0.3- μm-thick electrolytic Pd layer was plated on 1 μm of electroless Ni on 1 mm-thick polished and roughened Cu substrates with roughness values ( R a) of 0.08 μm and 0.5 μm, respectively. The rough substrates were produced with sand-blasting. Au wire bonding on the Ni/Pd surface was optimized, and the electrical reliability was investigated under a high temperature storage test (HTST) during 800 h at 250°C by measuring the ball bond contact resistance, R c. The average value of R c of optimized ball bonds on the rough substrate was 1.96 mΩ which was about 40.0% higher than that on the smooth substrate. The initial bondability increased for the rougher surface, so that only half of the original ultrasonic level was required, but the reliability was not affected by surface roughness. For both substrate types, HTST caused bond healing, reducing the average R c by about 21% and 27%, respectively. Au diffusion into the Pd layer was observed in scanning transmission electron microscopy/ energy dispersive spectroscopy (STEM-EDS) line-scan analysis after HTST. It is considered that diffusion of Au or interdiffusion between Au and Pd can provide chemically strong bonding during HTST. This is supported by the R c decrease measured as the aging time increased. Cu migration was indicated in the STEM-EDS analysis, but its effect on reliability can be ignored. Au and Pd tend to form a complete solid solution at the interface and can provide reliable interconnection for high temperature (250°C) applications.
Gideon, Nicole; Hawkes, Nick; Mond, Jonathan; Saunders, Rob; Tchanturia, Kate; Serpell, Lucy
2016-01-01
Objective The aim of this study was to develop and validate a short form of the Eating Disorder Examination Questionnaire (EDE-Q) for routine, including session by session, outcome assessment. Method The current, 28-item version (6.0) of the EDE-Q was completed by 489 individuals aged 18–72 with various eating disorders recruited from three UK specialist eating disorder services. Rasch analysis was carried out on factors identified by means of principal component analysis, which in combination with expert ratings informed the development of an EDE-Q short form. The shortened questionnaire’s reliability, validity and sensitivity was assessed based on online data collected from students of a UK university and volunteers with a history of eating disorders recruited from a national eating disorders charity aged 18–74 (N = 559). Results A 12-item short form, the Eating Disorder Examination Questionnaire Short (EDE-QS) was derived. The new measure showed high internal consistency (Cronbach’s α = .913) and temporal stability (ICC = .93; p eating disorder and comorbid psychopathology. It was sufficiently sensitive to distinguish between people with and without eating disorders. Discussion The EDE-QS is a brief, reliable and valid measure of eating disorder symptom severity that performs similarly to the EDE-Q and that lends itself for the use of sessional outcome monitoring in treatment and research. PMID:27138364
Reliability and Validity of Selected PROMIS Measures in People with Rheumatoid Arthritis.
Directory of Open Access Journals (Sweden)
Susan J Bartlett
Full Text Available To evaluate the reliability and validity of 11 PROMIS measures to assess symptoms and impacts identified as important by people with rheumatoid arthritis (RA.Consecutive patients (N = 177 in an observational study completed PROMIS computer adapted tests (CATs and a short form (SF assessing pain, fatigue, physical function, mood, sleep, and participation. We assessed test-test reliability and internal consistency using correlation and Cronbach's alpha. We assessed convergent validity by examining Pearson correlations between PROMIS measures and existing measures of similar domains and known groups validity by comparing scores across disease activity levels using ANOVA.Participants were mostly female (82% and white (83% with mean (SD age of 56 (13 years; 24% had ≤ high school, 29% had RA ≤ 5 years with 13% ≤ 2 years, and 22% were disabled. PROMIS Physical Function, Pain Interference and Fatigue instruments correlated moderately to strongly (rho's ≥ 0.68 with corresponding PROs. Test-retest reliability ranged from .725-.883, and Cronbach's alpha from .906-.991. A dose-response relationship with disease activity was evident in Physical Function with similar trends in other scales except Anger.These data provide preliminary evidence of reliability and construct validity of PROMIS CATs to assess RA symptoms and impacts, and feasibility of use in clinical care. PROMIS instruments captured the experiences of RA patients across the broad continuum of RA symptoms and function, especially at low disease activity levels. Future research is needed to evaluate performance in relevant subgroups, assess responsiveness and identify clinically meaningful changes.
Directory of Open Access Journals (Sweden)
Yiguang Chen
2017-11-01
Full Text Available With the development of electric vehicles and More-Electric/All-Electric aircraft, high reliability is required in motor servo systems. The redundancy technique is one of the most effective methods to improve the reliability of motor servo systems. In this paper, the structure of dual-redundancy permanent magnet synchronous motor (DRPMSM with weak thermal coupling and no electromagnetic coupling is analyzed and the mathematical model of this motor is established. However, there is little research on how to suppress the torque ripple caused by short-circuited coils in the DRPMSM. The main contribution of this paper is to present the advantages of DRPMSM and to find a way to suppress the torque ripple caused by the short circuit fault in DRPMSM. In order to improve operation quality and enhance the reliability of DRPMSM after a short circuit occurs, the torque ripple caused by the coils inter-turn short circuit fault in DRPMSM is analyzed in detail. Then, a control method for suppressing the electromagnetic torque ripple of a short-circuited coil is proposed for the first time by using an improved adaptive proportional resonant (PR controller and a proportional integral (PI controller in parallel. PR control is a method of controlling alternating components without steady-state error, and it can be used to suppress torque ripple. DRPMSM adopts speed and current double closed-loop control strategies. An improved adaptive PR controller and a PI controller are employed in parallel for the speed loop, while traditional PI control is adopted in current loop. From the simulation and experimental results, the torque ripple is reduced from 45.4 to 5.6% when the torque ripple suppression strategy proposed in this paper is adopted, in the case that the speed is 600 r/min. The torque ripple suppression strategy based on the PR controller can quickly and effectively suppress the torque ripple caused by the short-circuited coils, which makes the motor speed
2014-01-01
Background Following transmission, HIV-1 evolves into a diverse population, and next generation sequencing enables us to detect variants occurring at low frequencies. Studying viral evolution at the level of whole genomes was hitherto not possible because next generation sequencing delivers relatively short reads. Results We here provide a proof of principle that whole HIV-1 genomes can be reliably reconstructed from short reads, and use this to study the selection of immune escape mutations at the level of whole genome haplotypes. Using realistically simulated HIV-1 populations, we demonstrate that reconstruction of complete genome haplotypes is feasible with high fidelity. We do not reconstruct all genetically distinct genomes, but each reconstructed haplotype represents one or more of the quasispecies in the HIV-1 population. We then reconstruct 30 whole genome haplotypes from published short sequence reads sampled longitudinally from a single HIV-1 infected patient. We confirm the reliability of the reconstruction by validating our predicted haplotype genes with single genome amplification sequences, and by comparing haplotype frequencies with observed epitope escape frequencies. Conclusions Phylogenetic analysis shows that the HIV-1 population undergoes selection driven evolution, with successive replacement of the viral population by novel dominant strains. We demonstrate that immune escape mutants evolve in a dependent manner with various mutations hitchhiking along with others. As a consequence of this clonal interference, selection coefficients have to be estimated for complete haplotypes and not for individual immune escapes. PMID:24996694
Product reliability and the reliability of its emanating operational processes.
Sonnemans, P.J.M.; Geudens, W.H.J.M.
1999-01-01
This paper addresses the problem of proper reliability management in business operations today, facing increasing demands on essential business drivers such as time to market, quality and financial profit. In this paper a general method is described of how to achieve product quality in a highly
Improving Power Converter Reliability
DEFF Research Database (Denmark)
Ghimire, Pramod; de Vega, Angel Ruiz; Beczkowski, Szymon
2014-01-01
of a high-power IGBT module during converter operation, which may play a vital role in improving the reliability of the power converters. The measured voltage is used to estimate the module average junction temperature of the high and low-voltage side of a half-bridge IGBT separately in every fundamental......The real-time junction temperature monitoring of a high-power insulated-gate bipolar transistor (IGBT) module is important to increase the overall reliability of power converters for industrial applications. This article proposes a new method to measure the on-state collector?emitter voltage...... is measured in a wind power converter at a low fundamental frequency. To illustrate more, the test method as well as the performance of the measurement circuit are also presented. This measurement is also useful to indicate failure mechanisms such as bond wire lift-off and solder layer degradation...
Cabanas-Sánchez, Verónica; Tejero-González, Carlos M; Veiga, Oscar L
2012-01-01
One of the main problems of health in the first world is the increase of physical inactivity. In this respect, adolescence has been identified as a critic period with high decline of physical activity. Therefore, a relevant line of research is the understanding of this social phenomenon. The aim of this study was to design a scale to assess perceived barriers to physical activity on adolescents. A convenience sample of 160 Spanish adolescents (84 girls), between 12 and 18 years old, was recruited for this study. Firstly, there were designed 40 items whose pertinence was evaluated through content validation by experts. Later, the participants were divided in two randomized groups, and Exploratory Factor Analysis and Confirmatory Factor Analysis were performed to define a short scale of 12 items. Cronbach Alfa Coefficent was used to evaluate internal consistence of the instrument. The scale reports four dimensions: incompatibility barriers (2 items), self-concept barriers (4 items), amotivation barriers (4 items) and social barriers (2 items). The scale showed enough construct validity (χ2=60.78; d.f.=48; p=0.100; GFI=0.88; CFI=0.94; RMSEA=0.58) and high internal reliability (α=0.80). Moreover, the scale was able to explain 67% of the data variance. The Short Scale of Perceived Barriers to Physical Activity in Adolescents is a valid and reliable instrument.
García-Fernández, José M; Inglés, Cándido J; Marzo, Juan C; Martínez-Monteagudo, María C
2014-05-01
The School Anxiety Inventory (SAI) can be applied in different fields of psychology. However, due to the inventory's administration time, it may not be useful in certain situations. To address this concern, the present study developed a short version of the SAI (the SAI-SV). This study examined the reliability and validity evidence drawn from the scores of the School Anxiety Inventory-Short Version (SAI-SV) using a sample of 2,367 (47.91% boys) Spanish secondary school students, ranging from 12 to 18 years of age. To analyze the dimensional structure of the SAI-SV, exploratory and confirmatory factor analyses were applied. Internal consistency and test-retest reliability were calculated for SAI-SV scores. A correlated three-factor structure related to school situations (Anxiety about Aggression, Anxiety about Social Evaluation, and Anxiety about Academic Failure) and a three-factor structure related to the response systems of anxiety (Physiological Anxiety, Cognitive Anxiety, and Behavioral Anxiety) were identified and supported. The internal consistency and test-retest reliability were determined to be appropriate. The reliability and validity evidence based on the internal structure of SAI-SV scores was satisfactory.
Design for Reliability in Renewable Energy Systems
DEFF Research Database (Denmark)
Blaabjerg, Frede; Zhou, Dao; Sangwongwanich, Ariya
2017-01-01
Power electronics are widely used in renewable energy systems to achieve lower cost of energy, higher efficiency and high power density. At the same time, the high reliability of the power electronics products is demanded, in order to reduce the failure rates and ensure cost-effective operation...... of the renewable energy systems. This paper thus describes the basic concepts used in reliability engineering, and presents the status and future trends of Design for Reliability (DfR) in power electronics, which is currently undergoing a paradigm shift to a physics-of-failure approach. Two case studies of a 2 MW...
Energy Technology Data Exchange (ETDEWEB)
Herman Shen, M.-H. [Ohio State Univ., Columbus, OH (United States). Dept. of Aerospace Engineering and Aviation; Nicholas, T. [MLLN, Wright-Patterson AFB, OH (United States). Air Force Research Lab.
2001-07-01
A framework for the probabilistic analysis of high cycle fatigue is developed. The framework will be useful to U.S. Air Force and aeroengine manufacturers in the design of high cycle fatigue in disk or compressor components fabricated from Ti-6Al-4V under a range of loading conditions that might be encountered during service. The main idea of the framework is to characterize vibratory stresses from random input variables due to uncertainties such as crack location, loading, material properties, and manufacturing variability. The characteristics of such vibratory stresses are portrayed graphically as histograms, or probability density function (PDF). The outcome of the probability measures associated with all the values of a random variable exceeding the material capability is achieved by a failure function g(X) defined by the difference between the vibratory stress and Goodman line or surface such that the probability of HCF failure is P{sub f} =P(g(X<0)). Design can then be based on a go-no go criterion based on an assumed risk. The framework can be used to facilitate the development of design tools for the prediction of inspection schedules and reliability in aeroengine components. Such tools could lead ultimately to improved life extension schemes in aging aircraft, and more reliable methods for the design and inspection of critical components. (orig.)
Sorsdahl, Anne Brit; Moe-Nilssen, Rolf; Strand, Liv Inger
2008-01-01
The purpose of this study was to examine test-retest reliability of seven selected temporal and spatial gait parameters and asymmetry measures in children with cerebral palsy. Seventeen children with CP between 3 and 13 years of age walked at three different speeds across an electronic walkway of 5.2m. The tests were repeated after approximately 25 min. The scores were normalized to a walking speed of 1.1m/s to avoid the confounding effect of gait speed on speed dependent gait parameters. Intraclass correlation coefficients (ICC(1,1) and ICC(3,1)) with 95% confidence intervals, within-subject standard deviation (S(w)) and smallest detectable difference (SDD) were calculated. The relative reliability of cadence, step length, stride length and single stance time was high to excellent (ICC(1,1) between 0.73 and 0.95), while it was poor for step width (ICC(1,1)=0.27 and 0.35). The relative reliability for two calculated asymmetry measures were high for the step length index (ICC(1,1)=0.82) and moderate for the single stance time index (ICC(1,1)=0.49). The absolute reliability values for all gait parameters are reported. Five of seven gait parameters measured by an electronic walkway and normalized to a common walking speed, appear to be highly repeatable in a short-term time span in children with CP who were able to walk without assistive walking devices, provided sufficient cognitive function.
Scaled CMOS Technology Reliability Users Guide
White, Mark
2010-01-01
The desire to assess the reliability of emerging scaled microelectronics technologies through faster reliability trials and more accurate acceleration models is the precursor for further research and experimentation in this relevant field. The effect of semiconductor scaling on microelectronics product reliability is an important aspect to the high reliability application user. From the perspective of a customer or user, who in many cases must deal with very limited, if any, manufacturer's reliability data to assess the product for a highly-reliable application, product-level testing is critical in the characterization and reliability assessment of advanced nanometer semiconductor scaling effects on microelectronics reliability. A methodology on how to accomplish this and techniques for deriving the expected product-level reliability on commercial memory products are provided.Competing mechanism theory and the multiple failure mechanism model are applied to the experimental results of scaled SDRAM products. Accelerated stress testing at multiple conditions is applied at the product level of several scaled memory products to assess the performance degradation and product reliability. Acceleration models are derived for each case. For several scaled SDRAM products, retention time degradation is studied and two distinct soft error populations are observed with each technology generation: early breakdown, characterized by randomly distributed weak bits with Weibull slope (beta)=1, and a main population breakdown with an increasing failure rate. Retention time soft error rates are calculated and a multiple failure mechanism acceleration model with parameters is derived for each technology. Defect densities are calculated and reflect a decreasing trend in the percentage of random defective bits for each successive product generation. A normalized soft error failure rate of the memory data retention time in FIT/Gb and FIT/cm2 for several scaled SDRAM generations is
Properties and structure of high erbium doped phosphate glass for short optical fibers amplifiers
International Nuclear Information System (INIS)
Seneschal, Karine; Smektala, Frederic; Bureau, Bruno; Floch, Marie Le; Jiang Shibin; Luo, Tao; Lucas, Jacques; Peyghambarian, Nasser
2005-01-01
New phosphate glasses have been developed in order to incorporate high rare-earth ions concentrations. These glasses present a great chemical stability and a high optical quality. The phosphate glass network is open, very flexible, with a linkage of the tetrahedrons very disordered and contains a larger number of non-bridging oxygens (66%). The great stability and resistance against crystallization associated with the possibility to incorporate high doping concentration of rare-earth ions in these phosphate glasses make them very good candidates for the realization of ultra short single mode amplifiers with a high gain at 1.55 μm
Quantifying complexity of financial short-term time series by composite multiscale entropy measure
Niu, Hongli; Wang, Jun
2015-05-01
It is significant to study the complexity of financial time series since the financial market is a complex evolved dynamic system. Multiscale entropy is a prevailing method used to quantify the complexity of a time series. Due to its less reliability of entropy estimation for short-term time series at large time scales, a modification method, the composite multiscale entropy, is applied to the financial market. To qualify its effectiveness, its applications in the synthetic white noise and 1 / f noise with different data lengths are reproduced first in the present paper. Then it is introduced for the first time to make a reliability test with two Chinese stock indices. After conducting on short-time return series, the CMSE method shows the advantages in reducing deviations of entropy estimation and demonstrates more stable and reliable results when compared with the conventional MSE algorithm. Finally, the composite multiscale entropy of six important stock indices from the world financial markets is investigated, and some useful and interesting empirical results are obtained.
Impact of Loss Synchronization on Reliable High Speed Networks: A Model Based Simulation
Directory of Open Access Journals (Sweden)
Suman Kumar
2014-01-01
Full Text Available Contemporary nature of network evolution demands for simulation models which are flexible, scalable, and easily implementable. In this paper, we propose a fluid based model for performance analysis of reliable high speed networks. In particular, this paper aims to study the dynamic relationship between congestion control algorithms and queue management schemes, in order to develop a better understanding of the causal linkages between the two. We propose a loss synchronization module which is user configurable. We validate our model through simulations under controlled settings. Also, we present a performance analysis to provide insights into two important issues concerning 10 Gbps high speed networks: (i impact of bottleneck buffer size on the performance of 10 Gbps high speed network and (ii impact of level of loss synchronization on link utilization-fairness tradeoffs. The practical impact of the proposed work is to provide design guidelines along with a powerful simulation tool to protocol designers and network developers.
Quasi-Optical Network Analyzers and High-Reliability RF MEMS Switched Capacitors
Grichener, Alexander
The thesis first presents a 2-port quasi-optical scalar network analyzer consisting of a transmitter and receiver both built in planar technology. The network analyzer is based on a Schottky-diode mixer integrated inside a planar antenna and fed differentially by a CPW transmission line. The antenna is placed on an extended hemispherical high-resistivity silicon substrate lens. The LO signal is swept from 3-5 GHz and high-order harmonic mixing in both up- and down- conversion mode is used to realize the 15-50 GHz RF bandwidth. The network analyzer resulted in a dynamic range of greater than 40 dB and was successfully used to measure a frequency selective surface with a second-order bandpass response. Furthermore, the system was built with circuits and components for easy scaling to millimeter-wave frequencies which is the primary motivation for this work. The application areas for a millimeter and submillimeter-wave network analyzer include material characterization and art diagnostics. The second project presents several RF MEMS switched capacitors designed for high-reliability operation and suitable for tunable filters and reconfigurable networks. The first switched-capacitor resulted in a digital capacitance ratio of 5 and an analog capacitance ratio of 5-9. The analog tuning of the down-state capacitance is enhanced by a positive vertical stress gradient in the the beam, making it ideal for applications that require precision tuning. A thick electroplated beam resulted in Q greater than 100 at C to X-band frequencies, and power handling of 0.6-1.1 W. The design also minimized charging in the dielectric, resulting in excellent reliability performance even under hot-switched and high power (1 W) conditions. The second switched-capacitor was designed without any dielectric to minimize charging. The device was hot-switched at 1 W of RF power for greater than 11 billion cycles with virtually no change in the C-V curve. The final project presents a 7-channel
Designing reliability into accelerators
International Nuclear Information System (INIS)
Hutton, A.
1992-08-01
For the next generation of high performance, high average luminosity colliders, the ''factories,'' reliability engineering must be introduced right at the inception of the project and maintained as a central theme throughout the project. There are several aspects which will be addressed separately: Concept; design; motivation; management techniques; and fault diagnosis
Extra-high short-circuit current for bifacial solar cells in sunny and dark-light conditions.
Duan, Jialong; Duan, Yanyan; Zhao, Yuanyuan; He, Benlin; Tang, Qunwei
2017-09-05
We present here a symmetrically structured bifacial solar cell tailored by two fluorescent photoanodes and a platinum/titanium/platinum counter electrode, yielding extra-high short-circuit current densities as high as 28.59 mA cm -2 and 119.9 μA cm -2 in simulated sunlight irradiation (100 mW cm -2 , AM1.5) and dark-light conditions, respectively.
Directory of Open Access Journals (Sweden)
Ирина Александровна Гавриленко
2016-02-01
Full Text Available The approach to automated management of load flow in engineering networks considering functional reliability was proposed in the article. The improvement of the concept of operational and strategic management of load flow in engineering networks was considered. The verbal statement of the problem for thesis research is defined, namely, the problem of development of information technology for exact calculation of the functional reliability of the network, or the risk of short delivery of purpose-oriented product for consumers
International Nuclear Information System (INIS)
Nakagawa, K; Tanaka, T; Suzuki, T
2015-01-01
This paper presents the fabrication of a new energy harvesting module that uses a thermoelectric device (TED) by using molding technology. Through molding technology, the TED and circuit board can be properly protected and a heat-radiating fin structure can be simultaneously constructed. The output voltage per heater temperature of the TED module at 20 °C ambient temperature is 8 mV K −1 , similar to the result with the aluminum heat sink which is almost the same fin size as the TED module. The accelerated environmental tests are performed on a damp heat test, which is an aging test under high temperature and high humidity, highly accelerated temperature, and humidity stress test (HAST) for the purpose of evaluating the electrical reliability in harsh environments, cold test and thermal cycle test to evaluate degrading characteristics by cycling through two temperatures. All test results indicate that the TED and circuit board can be properly protected from harsh temperature and humidity by using molding technology because the output voltage of after-tested modules is reduced by less than 5%. This study presents a novel fabrication method for a high reliability TED-installed module appropriate for Machine to Machine wireless sensor networks. (paper)
Does visual short-term memory have a high-capacity stage?
Matsukura, Michi; Hollingworth, Andrew
2011-12-01
Visual short-term memory (VSTM) has long been considered a durable, limited-capacity system for the brief retention of visual information. However, a recent work by Sligte et al. (Plos One 3:e1699, 2008) reported that, relatively early after the removal of a memory array, a cue allowed participants to access a fragile, high-capacity stage of VSTM that is distinct from iconic memory. In the present study, we examined whether this stage division is warranted by attempting to corroborate the existence of an early, high-capacity form of VSTM. The results of four experiments did not support Sligte et al.'s claim, since we did not obtain evidence for VSTM retention that exceeded traditional estimates of capacity. However, performance approaching that observed in Sligte et al. can be achieved through extensive practice, providing a clear explanation for their findings. Our evidence favors the standard view of VSTM as a limited-capacity system that maintains a few object representations in a relatively durable form.
Çapri, Burhan; Gündüz, Bülent; Akbay, Sinem Evin
2017-01-01
The primary goal of this study is to complete the adaptation, validity and reliability studies of the long (17 items) and short (9 items) forms of UWES-SF. The secondary goal of this study is to study the mediating role of work engagement between academic procrastination and academic responsibility in high school students. The study group consists…
High ion charge states in a high-current, short-pulse, vacuum ARC ion sources
International Nuclear Information System (INIS)
Anders, A.; Brown, I.; MacGill, R.; Dickinson, M.
1996-01-01
Ions of the cathode material are formed at vacuum arc cathode spots and extracted by a grid system. The ion charge states (typically 1-4) depend on the cathode material and only little on the discharge current as long as the current is low. Here the authors report on experiments with short pulses (several μs) and high currents (several kA); this regime of operation is thus approaching a more vacuum spark-like regime. Mean ion charge states of up to 6.2 for tungsten and 3.7 for titanium have been measured, with the corresponding maximum charge states of up to 8+ and 6+, respectively. The results are discussed in terms of Saha calculations and freezing of the charge state distribution
High ion charge states in a high-current, short-pulse, vacuum arc ion source
International Nuclear Information System (INIS)
Anders, A.; Brown, I.; MacGill, R.; Dickinson, M.
1995-09-01
Ions of the cathode material are formed at vacuum arc cathode spots and extracted by a grid system. The ion charge states (typically 1--4) depend on the cathode material and only little on the discharge current as long as the current is low. Here the authors report on experiments with short pulses (several micros) and high currents (several kA); this regime of operation is thus approaching a more vacuum spark-like regime. Mean ion charge states of up to 6.2 for tungsten and 3.7 for titanium have been measured, with the corresponding maximum charge states of up to 8+ and 6+, respectively. The results are discussed in terms of Saha calculations and freezing of the charge state distribution
Test-retest reliability and practice effects of the Wechsler Memory Scale-III.
Lo, Ada H Y; Humphreys, Michael; Byrne, Gerard J; Pachana, Nancy A
2012-09-01
Although serial administration of cognitive tests is increasingly common, there is a paucity of research on test-retest reliabilities and practice effects, both of which are important for evaluating changes in functioning. Reliability is generally conceptualized as involving short-lasting changes in performance. However, when repeated testing occurs over a period of years, there will be some longer lasting effects. The implications of these longer lasting effects and practice effects on reliability were examined in the context of repeated administrations of the Wechsler Memory Scale-III in 339 community-dwelling women aged 40-79 years over 2 to 7 years. The results showed that Logical Memory and Verbal Paired Associates subtests were consistently the most reliable subtests across the age cohorts. The magnitude of practice effects varied as a function of subtests and age. The largest practice effects were found in the youngest age cohort, especially on the Faces, Logical Memory, and Verbal Paired Associates subtests. ©2012 The British Psychological Society.
Directory of Open Access Journals (Sweden)
Penny Moss
Full Text Available Increased sensitivity to cold may be a predictor of persistent pain, but cold pain threshold is often viewed as unreliable. This study aimed to determine the within-subject reliability and between-subject variance of cold response, measured comprehensively as cold pain threshold plus pain intensity and sensation quality at threshold. A test-retest design was used over three sessions, one day apart. Response to cold was assessed at four sites (thenar eminence, volar forearm, tibialis anterior, plantar foot. Cold pain threshold was measured using a Medoc thermode and standard method of limits. Intensity of pain at threshold was rated using a 10cm visual analogue scale. Quality of sensation at threshold was quantified with indices calculated from subjects' selection of descriptors from a standard McGill Pain Questionnaire. Within-subject reliability for each measure was calculated with intra-class correlation coefficients and between-subject variance was evaluated as group coefficient of variation percentage (CV%. Gender and site comparisons were also made. Forty-five healthy adults participated: 20 male, 25 female; mean age 29 (range 18-56 years. All measures at all four test sites showed high within-subject reliability: cold pain thresholds r = 0.92-0.95; pain rating r = 0.93-0.97; McGill pain quality indices r = 0.87-0.85. In contrast, all measures showed wide between-subject variance (CV% between 51.4% and 92.5%. Upper limb sites were consistently more sensitive than lower limb sites, but equally reliable. Females showed elevated cold pain thresholds, although similar pain intensity and quality to males. Females were also more reliable and showed lower variance for all measures. Thus, although there was clear population variation, response to cold for healthy individuals was found to be highly reliable, whether measured as pain threshold, pain intensity or sensation quality. A comprehensive approach to cold response testing therefore may add
Moss, Penny; Whitnell, Jasmine; Wright, Anthony
2016-01-01
Increased sensitivity to cold may be a predictor of persistent pain, but cold pain threshold is often viewed as unreliable. This study aimed to determine the within-subject reliability and between-subject variance of cold response, measured comprehensively as cold pain threshold plus pain intensity and sensation quality at threshold. A test-retest design was used over three sessions, one day apart. Response to cold was assessed at four sites (thenar eminence, volar forearm, tibialis anterior, plantar foot). Cold pain threshold was measured using a Medoc thermode and standard method of limits. Intensity of pain at threshold was rated using a 10cm visual analogue scale. Quality of sensation at threshold was quantified with indices calculated from subjects' selection of descriptors from a standard McGill Pain Questionnaire. Within-subject reliability for each measure was calculated with intra-class correlation coefficients and between-subject variance was evaluated as group coefficient of variation percentage (CV%). Gender and site comparisons were also made. Forty-five healthy adults participated: 20 male, 25 female; mean age 29 (range 18-56) years. All measures at all four test sites showed high within-subject reliability: cold pain thresholds r = 0.92-0.95; pain rating r = 0.93-0.97; McGill pain quality indices r = 0.87-0.85. In contrast, all measures showed wide between-subject variance (CV% between 51.4% and 92.5%). Upper limb sites were consistently more sensitive than lower limb sites, but equally reliable. Females showed elevated cold pain thresholds, although similar pain intensity and quality to males. Females were also more reliable and showed lower variance for all measures. Thus, although there was clear population variation, response to cold for healthy individuals was found to be highly reliable, whether measured as pain threshold, pain intensity or sensation quality. A comprehensive approach to cold response testing therefore may add validity and
Chen, Y-W; HajGhanbari, B; Road, J D; Coxson, H O; Camp, P G; Reid, W D
2018-06-08
Pain is prevalent in chronic obstructive pulmonary disease (COPD) and the Brief Pain Inventory (BPI) appears to be a feasible questionnaire to assess this symptom. However, the reliability and validity of the BPI have not been determined in individuals with COPD. This study aimed to determine the internal consistency, test-retest reliability and validity (construct, convergent, divergent and discriminant) of the BPI in individuals with COPD. In order to examine the test-retest reliability, individuals with COPD were recruited from pulmonary rehabilitation programmes to complete the BPI twice 1 week apart. In order to investigate validity, de-identified data was retrieved from two previous studies, including forced expiratory volume in 1-s, age, sex and data from four questionnaires: the BPI, short-form McGill Pain Questionnaire (SF-MPQ), 36-Item Short Form Survey (SF-36) and Community Health Activities Model Program for Seniors (CHAMPS) questionnaire. In total, 123 participants were included in the analyses (eligible data were retrieved from 86 participants and additional 37 participants were recruited). The BPI demonstrated excellent internal consistency and test-retest reliability. It also showed convergent validity with the SF-MPQ and divergent validity with the SF-36. The factor analysis yielded two factors of the BPI, which demonstrated that the two domains of the BPI measure the intended constructs. The BPI can also discriminate pain levels among COPD patients with varied levels of quality of life (SF-36) and physical activity (CHAMPS). The BPI is a reliable and valid pain questionnaire that can be used to evaluate pain in COPD. This study formally established the reliability and validity of the BPI in individuals with COPD, which have not been determined in this patient group. The results of this study provide strong evidence that assessment results from this pain questionnaire are reliable and valid. © 2018 European Pain Federation - EFIC®.
A high performance electrometer amplifier of hybrid design
International Nuclear Information System (INIS)
Rao, N.V.; Nazare, C.K.
1979-01-01
A high performance, reliable, electrometer amplifier of hybrid design for low current measurements in mass spectrometers has been developed. The short term instability with a 5 x 10 11 ohms input resistor is less than 1 x 10sup(-15) Amp. The drift is better than 1 mV/hour. The design steps are illustrated with a typical amplifier performance details. (auth.)
Chang, Li-Chun; Hsieh, Pei-Lin; Liu, Chieh-Hsing
2012-09-01
The purpose of this study is to develop and evaluate the psychometric properties of the Chinese version of short-form Test of Functional Health Literacy in Adolescents. Assessing health literacy is vital to design health education programme; however, there are no measurement tools exist for use specifically in Chinese adolescents. A non-experimental design was used to test the psychometric properties of the Test of Functional Health Literacy in Adolescents. The short-form Test of Functional Health Literacy in Adolescents was translated and back translated into a Chinese language version. Thirty high school students were recruited to validate the scenario of Test of Functional Health Literacy in Adolescents. Based on the multiple-stage stratified random sampling method, 300 high school students from four counties in Taiwan were invited to participate in this study to evaluate the psychometric properties of Test of Functional Health Literacy in Adolescents. The Functional Health Literacy in Adolescents had good internal consistency reliability and excellent test-retest reliability. Confirmatory factor analysis resulted in a one-factor solution. Contrary to the original version of the Test of Functional Health Literacy in Adolescents, the findings revealed that the 36-item, one-factor model for the Test of Functional Health Literacy in Adolescents is the best-fit model. This is a suitable instrument to assess health literacy levels in Chinese adolescents before health education programmes can be appropriately planned, implemented and evaluated. © 2012 Blackwell Publishing Ltd.
A Computer Program for Short Circuit Analysis of Electric Power ...
African Journals Online (AJOL)
The Short Circuit Analysis Program (SCAP) is to be used to assess the composite effects of unbalanced and balanced faults on the overall reliability of electric power system. The program uses the symmetrical components method to compute all phase and sequence quantities for any bus or branch of a given power network ...
Highlights from the early (and pre-) history of reliability engineering
International Nuclear Information System (INIS)
Saleh, J.H.; Marais, K.
2006-01-01
Reliability is a popular concept that has been celebrated for years as a commendable attribute of a person or an artifact. From its modest beginning in 1816-the word reliability was first coined by Samuel T. Coleridge-reliability grew into an omnipresent attribute with qualitative and quantitative connotations that pervades every aspect of our present day technologically intensive world. In this short communication, we highlight key events and the history of ideas that led to the birth of Reliability Engineering, and its development in the subsequent decades. We first argue that statistics and mass production were the enablers in the rise of this new discipline, and the catalyst that accelerated the coming of this new discipline was the (unreliability of the) vacuum tube. We highlight the foundational role of AGREE report in 1957 in the birth of reliability engineering, and discuss the consolidation of numerous efforts in the 1950s into a coherent new technical discipline. We show that an evolution took place in the discipline in the following two decades along two directions: first, there was an increased specialization in the discipline (increased sophistication of statistical techniques, and the rise of a new branch focused on the actual physics of failure of components, Reliability Physics); second, there occurred a shift in the emphasis of the discipline from a component-centric to an emphasis on system-level attributes (system reliability, availability, safety). Finally, in selecting the particular events and highlights in the history of ideas that led to the birth and subsequent development of reliability engineering, we acknowledge a subjective component in this work and make no claims to exhaustiveness
Huo, Tianyao; Guo, Yi; Shenkman, Elizabeth; Muller, Keith
2018-02-13
Although Short Form (SF)-12 × 2® has been extensively studied and used as a valid measure of health-related quality of life in a variety of population groups, no systematic studies have described the reliability of the measure in patients with behavioral conditions or serious mental illness (SMI). We assessed the internal consistency, split-half reliability and annual test-retest correlations in a sample of 1587 participants with either a combination of physical and behavioral conditions or SMI. The Mosier's alpha was 0.70 for the Physical Composite Scale (PCS) and 0.69 for the Mental Health Composite Scale (MCS), indicating good internal consistency. We observed strong correlations between physical functioning, physical role and body pain scales (r = 0.55-0.56), and between social functioning, emotional role, and mental health (r = 0.53-0.58). We calculated split-half reliabilities to be 0.74 for physical functioning, 0.75 for physical role, 0.73 for emotional role and 0.65 for mental health respectively. We assessed the annual test-retest correlation using intraclass correlation (ICC) and found an ICC of 0.61 for PCS and 0.57 for MCS composite scores, adjusting for age, sex, race/ethnicity, and CRG. We found no decline in the correlations between baseline and the following study years until year 3. Our results encourage using SF-12v2® to assess health-related quality of life in the Medicaid population with combined physical and behavioral conditions or similar cohorts. The WIN study was registered with clinicaltrials.gov on April 22, 2015. NCT02440906 . Retrospectively registered.
Alternative ceramic circuit constructions for low cost, high reliability applications
International Nuclear Information System (INIS)
Modes, Ch.; O'Neil, M.
1997-01-01
The growth in the use of hybrid circuit technology has recently been challenged by recent advances in low cost laminate technology, as well as the continued integration of functions into IC's. Size reduction of hybrid 'packages' has turned out to be a means to extend the useful life of this technology. The suppliers of thick film materials technology have responded to this challenge by developing a number of technology options to reduce circuit size, increase density, and reduce overall cost, while maintaining or increasing reliability. This paper provides an overview of the processes that have been developed, and, in many cases are used widely to produce low cost, reliable microcircuits. Comparisons of each of these circuit fabrication processes are made with a discussion of advantages and disadvantages of each technology. (author)
Does Short-Term Hunger Increase Trust and Trustworthiness in a High Trust Society?
Directory of Open Access Journals (Sweden)
Elias Rantapuska
2017-11-01
Full Text Available We build on the social heuristics hypothesis, the literature on the glucose model of self-control, and recent challenges on these hypotheses to investigate whether individuals exhibit a change in degree of trust and reciprocation after consumption of a meal. We induce short-term manipulation of hunger followed by the trust game and a decision on whether to leave personal belongings in an unlocked and unsupervised room. Our results are inconclusive. While, we report hungry individuals trusting and reciprocating more than those who have just consumed a meal in a high trust society, we fail to reject the null with small number of observations (N = 101 and experimental sessions (N = 8. In addition, we find no evidence of short-term hunger having an impact on charitable giving or decisions in public good game.
Monticone, Marco; Baiardi, Paola; Ferrari, Silvano; Foti, Calogero; Mugnai, Raffaele; Pillastrini, Paolo; Vanti, Carla; Zanoli, Gustavo
2009-09-01
Evaluation of the psychometric properties of a translated, culturally adapted questionnaire. Translating, culturally adapting, and validating the Italian version of the Oswestry Disability Index (ODI-I), allowing its use in Italian-speaking patients with low back pain inside and outside Italy. Growing attention is devoted to standardized outcome measures to improve interventions for low back pain. A translated form of the ODI in patients with low back pain has never been validated within the Italian population. The ODI-I questionnaire was developed involving forward-backward translation, final review by an expert committee and test of the prefinal version to establish as better as possible proper correspondence with the original English latest version (2.1a). Psychometric testing included factor analysis, reliability by internal consistency (Cronbach alpha) and test-retest repeatability (Intraclass Coefficient Correlation), concurrent validity by comparing the ODI-I to Visual Analogue Scale, (Pearson correlation), and construct validity by comparing the ODI-I to Roland Morris Disability Questionnaire, RMDQ, and to Short Form Health Survey, Short Form Health Survey-36 (Pearson correlation). The authors required a 3-month period before achieving a shared version of the ODI-I. The questionnaire was administered to 126 subjects, showing satisfying acceptability. Factor analysis demonstrated a 1-factor structure (45% of explained variance). The questionnaire showed high internal consistency (alpha = 0.855) and good test-retest reliability (ICC = 0.961). Concurrent validity was confirmed by a high correlation with Visual Analogue Scale (r = 0.73, P < 0.001), Construct validity revealed high correlations with RMDQ (r = 0.819, P < 0.001), and with Short Form Health Survey-36 domains, highly significant with the exception of Mental Health (r = -0.139, P = 0.126). The ODI outcome measure was successfully translated into Italian, showing good factorial structure and
Chang, Chi-Cheng; Liang, Chaoyun; Chen, Yi-Hui
2013-01-01
This study explored the reliability and validity of Web-based portfolio self-assessment. Participants were 72 senior high school students enrolled in a computer application course. The students created learning portfolios, viewed peers' work, and performed self-assessment on the Web-based portfolio assessment system. The results indicated: 1)…
Directory of Open Access Journals (Sweden)
Jian-wei Yang
2015-01-01
Full Text Available Taking advantage of the high reliability, multiphase permanent magnet synchronous motors (PMSMs, such as five-phase PMSM and six-phase PMSM, are widely used in fault-tolerant control applications. And one of the important fault-tolerant control problems is fault diagnosis. In most existing literatures, the fault diagnosis problem focuses on the three-phase PMSM. In this paper, compared to the most existing fault diagnosis approaches, a fault diagnosis method for Interturn short circuit (ITSC fault of five-phase PMSM based on the trust region algorithm is presented. This paper has two contributions. (1 Analyzing the physical parameters of the motor, such as resistances and inductances, a novel mathematic model for ITSC fault of five-phase PMSM is established. (2 Introducing an object function related to the Interturn short circuit ratio, the fault parameters identification problem is reformulated as the extreme seeking problem. A trust region algorithm based parameter estimation method is proposed for tracking the actual Interturn short circuit ratio. The simulation and experimental results have validated the effectiveness of the proposed parameter estimation method.
Wong, M T P; Ho, T P; Ho, M Y; Yu, C S; Wong, Y H; Lee, S Y
2002-05-01
The Geriatric Depression Scale (GDS) is a common screening tool for elderly depression in Hong Kong. This study aimed at (1) developing a standardized manual for the verbal administration and scoring of the GDS-SF, and (2) comparing the inter-rater reliability between the standardized and non-standardized verbal administration of GDS-SF. Two studies were reported. In Study 1, the process of developing the manual was described. In Study 2, we compared the inter-rater reliabilities of GDS-SF scores using the standardized verbal instructions and the traditional non-standardized administration. Results of Study 2 indicated that the standardized procedure in verbal administration and scoring improved the inter-rater reliabilities of GDS-SF. Copyright 2002 John Wiley & Sons, Ltd.
Reliability and Validity of the New Tanaka B Intelligence Scale Scores: A Group Intelligence Test
Uno, Yota; Mizukami, Hitomi; Ando, Masahiko; Yukihiro, Ryoji; Iwasaki, Yoko; Ozaki, Norio
2014-01-01
OBJECTIVE: The present study evaluated the reliability and concurrent validity of the new Tanaka B Intelligence Scale, which is an intelligence test that can be administered on groups within a short period of time. METHODS: The new Tanaka B Intelligence Scale and Wechsler Intelligence Scale for Children-Third Edition were administered to 81 subjects (mean age ± SD 15.2 ± 0.7 years) residing in a juvenile detention home; reliability was assessed using Cronbach's alpha coefficient, and concurre...
International Nuclear Information System (INIS)
2011-01-01
A collaborative study was started with the Middle East Technical University, Environmental Engineering Department in 2004 in order to determine the transport of air pollutants and their deposition rates to Eastern Mediterranean with the ultimate aim of filling the gaps in knowledge on the current status of Eastern Mediterranean air quality profile. Collection sufficient amount of representative samples, analyzes of the collected samples with high accuracy and precision and interpretation of generated data are crucial efforts. To attain this goal, EDXRF spectrometer, which is a rapid, reliable and sensitive analytical instrument, located at our center was employed in analysis of the collected samples after calibration with 'NIST 2783 Air Particles on Filter'. The effectiveness of the control strategies taken on the emissions was discussed by investigating the short and long term variations in the chemical composition of samples collected between 1993 and 2001 at Antalya station. In this context, generated data set was studied for short (daily) term, seasonal and long term variations. It has been found that short term variations in the concentrations of pollutants in short time scale are highly episodic. The concentration of measured pollutants was changed 10-20 folds in the subsequent two days. The most important factors affecting the chemical composition of pollutants in short time interval are meteorological factors such as precipitation and variations observed at the emission strength of pollutants. The declined in Pb concentrations at the Antalya station was attributed to observed decrease in Pb emissions in Europe after the introduction of leaded gasoline. Highest summer averages were reported for anthropogenic pollutants in summer months. Aegean Sea (Izmir-Aliaga) studies of the project will be completed this year
International Nuclear Information System (INIS)
Ohaeri, Jude U; Awadallab, Abdel W
2009-01-01
There is rising interest in quality of life (QOL) research in Arabian countries. The aim of this study was to assess in a nationwide sample of Kuwaiti subjects the reliability and validity of the World Health Organization Quality of Life (WHOQOL-BREF), a shorter version of the widely used QOL assessment instrument that comprises 26 items in the domains of physical health, psychological health, social relationships, and the environment. A one-in-three systematic random proportionate sample of consenting Kuwaiti nationals attending large cooperative stores and municipal government offices in the six governorates completed the Arabic translation of the questionnaire. The indices assessed included test-retest reliability, internal consistency, item internal consistency (2C), item discriminant validity (IDV), known-groups and construct validity. There were 3303 participants (44.8% males, 55.2% females, mean age 35.4 years, range 16 to 87 years). The intra-class correlation for the test-retest statistic and the internal consistency values for the full questionnaire and the domains had a Cronbach's alpha > - 0.7. Of the 24 items that constitute the domains, 21 met the 2 C requirement of correlation > - 0.4 with the corresponding domain, while 16 met the IDV criterion of having a higher correlation with their corresponding domain than other domains. Domain scores discriminated significantly between well and sick groups. In the factor analysis, four strong factors emerged with the same construct as in the WHO report. The Arabic translation of the WHOQOL-BREF has impressive reliability and validity indices. The poor IDV findings are due to the multidimensional nature of the questionnaire. The highly significant validity indices should reassure researchers that the questionnaire represents the same constructs across cultures. Negatively worded items possibly need refinement. (author)
Design for Reliability of Power Electronic Systems
DEFF Research Database (Denmark)
Wang, Huai; Ma, Ke; Blaabjerg, Frede
2012-01-01
Advances in power electronics enable efficient and flexible processing of electric power in the application of renewable energy sources, electric vehicles, adjustable-speed drives, etc. More and more efforts are devoted to better power electronic systems in terms of reliability to ensure high......). A collection of methodologies based on Physics-of-Failure (PoF) approach and mission profile analysis are presented in this paper to perform reliability-oriented design of power electronic systems. The corresponding design procedures and reliability prediction models are provided. Further on, a case study...... on a 2.3 MW wind power converter is discussed with emphasis on the reliability critical components IGBTs. Different aspects of improving the reliability of the power converter are mapped. Finally, the challenges and opportunities to achieve more reliable power electronic systems are addressed....
A Highly Reliable and Cost-Efficient Multi-Sensor System for Land Vehicle Positioning
Directory of Open Access Journals (Sweden)
Xu Li
2016-05-01
Full Text Available In this paper, we propose a novel positioning solution for land vehicles which is highly reliable and cost-efficient. The proposed positioning system fuses information from the MEMS-based reduced inertial sensor system (RISS which consists of one vertical gyroscope and two horizontal accelerometers, low-cost GPS, and supplementary sensors and sources. First, pitch and roll angle are accurately estimated based on a vehicle kinematic model. Meanwhile, the negative effect of the uncertain nonlinear drift of MEMS inertial sensors is eliminated by an H∞ filter. Further, a distributed-dual-H∞ filtering (DDHF mechanism is adopted to address the uncertain nonlinear drift of the MEMS-RISS and make full use of the supplementary sensors and sources. The DDHF is composed of a main H∞ filter (MHF and an auxiliary H∞ filter (AHF. Finally, a generalized regression neural network (GRNN module with good approximation capability is specially designed for the MEMS-RISS. A hybrid methodology which combines the GRNN module and the AHF is utilized to compensate for RISS position errors during GPS outages. To verify the effectiveness of the proposed solution, road-test experiments with various scenarios were performed. The experimental results illustrate that the proposed system can achieve accurate and reliable positioning for land vehicles.
Assessing the reliability of skilled performance
International Nuclear Information System (INIS)
Dougherty, E.M.; Collins, E.P.
1996-01-01
In some high-hazard military tasks, precision of motor skills is crucial to avoid a risk-sensitive drop or other mishap. Sparse data supports a basic level of reliability for this activity seemingly much lower than typical, individual action, slip-mode errors would yield. A typical occurrence failure rate seems to be of the order of 1 x 10 -5 per opportunity. A speculation is tendered that this represents a difference in kind; that the reliability of skills is a different taxon than previously called out in the typical scheme of human reliability
Multinomial-exponential reliability function: a software reliability model
International Nuclear Information System (INIS)
Saiz de Bustamante, Amalio; Saiz de Bustamante, Barbara
2003-01-01
The multinomial-exponential reliability function (MERF) was developed during a detailed study of the software failure/correction processes. Later on MERF was approximated by a much simpler exponential reliability function (EARF), which keeps most of MERF mathematical properties, so the two functions together makes up a single reliability model. The reliability model MERF/EARF considers the software failure process as a non-homogeneous Poisson process (NHPP), and the repair (correction) process, a multinomial distribution. The model supposes that both processes are statistically independent. The paper discusses the model's theoretical basis, its mathematical properties and its application to software reliability. Nevertheless it is foreseen model applications to inspection and maintenance of physical systems. The paper includes a complete numerical example of the model application to a software reliability analysis
NETWORK DESIGN IN CLOSE-RANGE PHOTOGRAMMETRY WITH SHORT BASELINE IMAGES
Directory of Open Access Journals (Sweden)
L. Barazzetti
2017-08-01
Full Text Available The avaibility of automated software for image-based 3D modelling has changed the way people acquire images for photogrammetric applications. Short baseline images are required to match image points with SIFT-like algorithms, obtaining more images than those necessary for “old fashioned” photogrammetric projects based on manual measurements. This paper describes some considerations on network design for short baseline image sequences, especially on precision and reliability of bundle adjustment. Simulated results reveal that the large number of 3D points used for image orientation has very limited impact on network precision.
Directory of Open Access Journals (Sweden)
Alexios Kythreotis
2015-08-01
Full Text Available Purpose – The degree of corruption, among other things, indicates the non -implementation of laws, weak enforcement of legal sanctions and the existence of non-transparent economic transactions. Therefore, the expected change in reliability (faithful-representation resulting from the adoption of IAS/IFRS, does not depend solely on the adoption of IAS/IFRS but is also influenced by the degree of corruption in each country. The purpose of this paper is to examine whether the above statement is true. Design/methodology/approach – The data were taken from DataStream database and the sample period consists of listed companies of fifteen European countries that adopted IAS/IFRS mandatorily. The time horizon is 10 years, from 2000 until 2009. The period between 2000 and 2004 is defined as the period before the adoption, while the period between 2005 and 2009 is defined as the period after the adoption. The reliability/faithful representation of financial statements - as defined by the Conceptual Framework - is detected through regression analysis. Findings – The findings advocate that the adoption of IFRS/IAS seems to be not enough. It appears that the level of reliability of financial statements in every country does not depend solely on the adoption of IAS/IFRS but is also influenced by the degree of corruption in each country. Research limitations/implications – The models that are used for the measurement of reliability have as an independent variable the short-term accruals. Given that, the models fail to take into consideration accounting treatments that concern non-current assets/liabilities. Originality/value – The findings that are identified for counties with a high degree of corruption indicate a statistically significant reduction in reliability after the adoption of IAS/IFRS. These findings constitute a useful tool for the IASB and the European Commission as well as for the users of financial statements.
Reliability analysis of component-level redundant topologies for solid-state fault current limiter
Farhadi, Masoud; Abapour, Mehdi; Mohammadi-Ivatloo, Behnam
2018-04-01
Experience shows that semiconductor switches in power electronics systems are the most vulnerable components. One of the most common ways to solve this reliability challenge is component-level redundant design. There are four possible configurations for the redundant design in component level. This article presents a comparative reliability analysis between different component-level redundant designs for solid-state fault current limiter. The aim of the proposed analysis is to determine the more reliable component-level redundant configuration. The mean time to failure (MTTF) is used as the reliability parameter. Considering both fault types (open circuit and short circuit), the MTTFs of different configurations are calculated. It is demonstrated that more reliable configuration depends on the junction temperature of the semiconductor switches in the steady state. That junction temperature is a function of (i) ambient temperature, (ii) power loss of the semiconductor switch and (iii) thermal resistance of heat sink. Also, results' sensitivity to each parameter is investigated. The results show that in different conditions, various configurations have higher reliability. The experimental results are presented to clarify the theory and feasibility of the proposed approaches. At last, levelised costs of different configurations are analysed for a fair comparison.
African Journals Online (AJOL)
eobe
Corresponding author, Tel: +234-703. RELIABILITY .... V , , given by the code of practice. However, checks must .... an optimization procedure over the failure domain F corresponding .... of Concrete Members based on Utility Theory,. Technical ...
Short-circuit tests of 1650 and 96 MVA transformers for 1300 MW french nuclear power plants
International Nuclear Information System (INIS)
Mailhot, M.
1989-01-01
Power evacuation and feeding of the auxiliaries directly from the 400 kV grid are sensitive points governing the security of 1300 MW PWR Nuclear Power Plants of the French Program. These two different functions are provided by two specific types of transformers. - Banks of 3 single-phase 550 MVA - 400 kV/20 kV transformers. - Three-phase 96 MVA - 400 kV / 3 x 6.8 kV transformers. These passive elements must have a never failing reliability and assure a continuous service in spite of electric, thermal and mechanical stresses that may occur during the lifetime of the power plant. Dielectric and thermal tests carried out in the manufacturers test floors insure these stresses withstand capabilities of transformers. In France, high short-circuit power for the 400 kV network added to often low impedance voltages for transformers impose on them very high stresses during short-circuits. Calculation and experimentation on scale or partial models are not sufficient to insure short-circuit currents withstand capabilities of transformers. The margin of uncertainty dependent on obligatory extrapolations for this kind of complex systems [steel, magnetic sheets, copper, oil, paper and transformerboard] can be reduced in a significant way only by real scale tests on prototypes. These tests that need both high power and voltage cannot be performed in manufacturers test floors. So, in France they are carried out at the EDF Les Renardieres Laboratory. Following paper deals with SHELL TYPE TRANSFORMERS which, particularly thanks to their interleaved rectangular windings display a great resistance to short-circuit stresses
Compliance and High Reliability in a Complex Healthcare Organization.
Simon, Maxine dellaBadia
2018-01-01
When considering the impact of regulation on healthcare, visualize a spider's web. The spider weaves sections together to create the whole, with each fiber adding to the structure to support its success or lead to its failure. Each section is dependent on the others, and all must be aligned to maintain the structure. Outside forces can cause a shift in the web's fragile equilibrium.The interdependence of the sections of the spider's web is similar to the way hospital departments and services work together. An organization's structure must be shaped to support its mission and vision. At the same time, the business of healthcare requires the development and achievement of operational objectives and financial performance goals. Establishing a culture that is flexible enough to permit creativity, provide resiliency, and manage complexity as the organization grows is fundamental to success. An organization must address each of these factors while maintaining stability, carrying out its mission, and fostering improvement.Nature's order maintains the spider's web. Likewise, regulation can strengthen healthcare organizations by initiating disruptive changes that can support efforts to achieve and sustain high reliability in the delivery of care. To that end, leadership must be willing to provide the necessary vision and resources.
Thomassin, Noémylle; Gonthier, Corentin; Guerraz, Michel; Roulin, Jean-Luc
2015-01-01
Participants with a high working memory span tend to perform better than low spans in a variety of tasks. However, their performance is paradoxically more impaired when they have to perform two tasks at once, a phenomenon that could be labeled the "hard fall effect." The present study tested whether this effect exists in a short-term memory task, and investigated the proposal that the effect is due to high spans using efficient facilitative strategies under simple task conditions. Ninety-eight participants performed a spatial short-term memory task under simple and dual task conditions; stimuli presentation times either allowed for the use of complex facilitative strategies or not. High spans outperformed low spans only under simple task conditions when presentation times allowed for the use of facilitative strategies. These results indicate that the hard fall effect exists on a short-term memory task and may be caused by individual differences in strategy use.
Measuring reliability under epistemic uncertainty: Review on non-probabilistic reliability metrics
Directory of Open Access Journals (Sweden)
Kang Rui
2016-06-01
Full Text Available In this paper, a systematic review of non-probabilistic reliability metrics is conducted to assist the selection of appropriate reliability metrics to model the influence of epistemic uncertainty. Five frequently used non-probabilistic reliability metrics are critically reviewed, i.e., evidence-theory-based reliability metrics, interval-analysis-based reliability metrics, fuzzy-interval-analysis-based reliability metrics, possibility-theory-based reliability metrics (posbist reliability and uncertainty-theory-based reliability metrics (belief reliability. It is pointed out that a qualified reliability metric that is able to consider the effect of epistemic uncertainty needs to (1 compensate the conservatism in the estimations of the component-level reliability metrics caused by epistemic uncertainty, and (2 satisfy the duality axiom, otherwise it might lead to paradoxical and confusing results in engineering applications. The five commonly used non-probabilistic reliability metrics are compared in terms of these two properties, and the comparison can serve as a basis for the selection of the appropriate reliability metrics.
Multilevel Confirmatory Factor Analysis of the Teacher My Class Inventory-Short Form
Villares, Elizabeth; Mariani, Melissa; Sink, Christopher A.; Colvin, Kimberly
2016-01-01
Researchers analyzed data from elementary teachers (N = 233) to further establish the psychometric soundness of the Teacher My Class Inventory-Short Form. Supporting previous psychometric research, confirmatory factor analyses findings supported the factorial validity of the hypothesized five-factor solution. Internal reliability estimates were…
International Nuclear Information System (INIS)
Wang, D.X.
1996-01-01
In recent years, there has been increasing interest in short electron bunches for different applications such as short wavelength FELs, linear colliders, and advanced accelerators such as laser or plasma wakefield accelerators. One would like to meet various requirements such as high peak current, low momentum spread, high luminosity, small ratio of bunch length to plasma wavelength, and accurate timing. Meanwhile, recent development and advances in RF photoinjectors and various bunching schemes make it possible to generate very short electron bunches. Measuring the longitudinal profile and monitoring bunch length are critical to understand the bunching process and longitudinal beam dynamics, and to commission and operate such short bunch machines. In this paper, several commonly used measurement techniques for subpicosecond bunches and their relative advantages and disadvantages are discussed. As examples, bunch length related measurements at Jefferson Lab are presented. At Jefferson Lab, bunch lengths as short as 84 fs have been systematically measured using a zero-phasing technique. A highly sensitive Coherent Synchrotron Radiation (CSR) detector has been developed to noninvasively monitor bunch length for low charge bunches. Phase transfer function measurements provide a means of correcting RF phase drifts and reproducing RF phases to within a couple of tenths of a degree. The measurement results are in excellent agreement with simulations. A comprehensive bunch length control scheme is presented. (author)
International Nuclear Information System (INIS)
Wang, D.X.
1996-01-01
In recent years, there has been increasing interest in short electron bunches for different applications such as short wavelength FELs, linear colliders, and advanced accelerators such as laser or plasma wakefield accelerators. One would like to meet various requirements such as high peak current, low momentum spread, high luminosity, small ratio of bunch length to plasma wavelength, and accurate timing. Meanwhile, recent development and advances in RF photoinjectors and various bunching schemes make it possible to generate very short electron bunches. Measuring the longitudinal profile and monitoring bunch length are critical to understand the bunching process and longitudinal beam dynamics, and to commission and operate such short bunch machines. In this paper, several commonly used measurement techniques for subpicosecond bunches and their relative advantages and disadvantages are discussed. As examples, bunch length related measurements at Jefferson lab are presented. At Jefferson Lab, bunch lengths s short as 84 fs have been systematically measured using a zero-phasing technique. A highly sensitive Coherent Synchrotron Radiation (CSR) detector has been developed to noninvasively monitor bunch length for low charge bunches. Phase transfer function measurements provide a means of correcting RF phase drifts and reproducing RF phases to within a couple of tenths of a degree. The measurement results are in excellent agreement with simulations. A comprehensive bunch length control scheme is presented
Reliability Approach of a Compressor System using Reliability Block ...
African Journals Online (AJOL)
pc
2018-03-05
Mar 5, 2018 ... This paper presents a reliability analysis of such a system using reliability ... Keywords-compressor system, reliability, reliability block diagram, RBD .... the same structure has been kept with the three subsystems: air flow, oil flow and .... and Safety in Engineering Design", Springer, 2009. [3] P. O'Connor ...
A reliable and consistent production technology for high volume compacted graphite iron castings
Directory of Open Access Journals (Sweden)
Liu Jincheng
2014-07-01
Full Text Available The demands for improved engine performance, fuel economy, durability, and lower emissions provide a continual challenge for engine designers. The use of Compacted Graphite Iron (CGI has been established for successful high volume series production in the passenger vehicle, commercial vehicle and industrial power sectors over the last decade. The increased demand for CGI engine components provides new opportunities for the cast iron foundry industry to establish efficient and robust CGI volume production processes, in China and globally. The production window range for stable CGI is narrow and constantly moving. Therefore, any one step single addition of magnesium alloy and the inoculant cannot ensure a reliable and consistent production process for complicated CGI engine castings. The present paper introduces the SinterCast thermal analysis process control system that provides for the consistent production of CGI with low nodularity and reduced porosity, without risking the formation of flake graphite. The technology is currently being used in high volume Chinese foundry production. The Chinese foundry industry can develop complicated high demand CGI engine castings with the proper process control technology.
Basu, Asit P; Basu, Sujit K
1998-01-01
This volume presents recent results in reliability theory by leading experts in the world. It will prove valuable for researchers, and users of reliability theory. It consists of refereed invited papers on a broad spectrum of topics in reliability. The subjects covered include Bayesian reliability, Bayesian reliability modeling, confounding in a series system, DF tests, Edgeworth approximation to reliability, estimation under random censoring, fault tree reduction for reliability, inference about changes in hazard rates, information theory and reliability, mixture experiment, mixture of Weibul
Lainscsek, Claudia; Weyhenmeyer, Jonathan; Hernandez, Manuel E; Poizner, Howard; Sejnowski, Terrence J
2013-01-01
Time series analysis with delay differential equations (DDEs) reveals non-linear properties of the underlying dynamical system and can serve as a non-linear time-domain classification tool. Here global DDE models were used to analyze short segments of simulated time series from a known dynamical system, the Rössler system, in high noise regimes. In a companion paper, we apply the DDE model developed here to classify short segments of encephalographic (EEG) data recorded from patients with Parkinson's disease and healthy subjects. Nine simulated subjects in each of two distinct classes were generated by varying the bifurcation parameter b and keeping the other two parameters (a and c) of the Rössler system fixed. All choices of b were in the chaotic parameter range. We diluted the simulated data using white noise ranging from 10 to -30 dB signal-to-noise ratios (SNR). Structure selection was supervised by selecting the number of terms, delays, and order of non-linearity of the model DDE model that best linearly separated the two classes of data. The distances d from the linear dividing hyperplane was then used to assess the classification performance by computing the area A' under the ROC curve. The selected model was tested on untrained data using repeated random sub-sampling validation. DDEs were able to accurately distinguish the two dynamical conditions, and moreover, to quantify the changes in the dynamics. There was a significant correlation between the dynamical bifurcation parameter b of the simulated data and the classification parameter d from our analysis. This correlation still held for new simulated subjects with new dynamical parameters selected from each of the two dynamical regimes. Furthermore, the correlation was robust to added noise, being significant even when the noise was greater than the signal. We conclude that DDE models may be used as a generalizable and reliable classification tool for even small segments of noisy data.
Development of high reliability dual redundant FADEC. Koshinraisei nijukei FADEC no kaihatsu
Energy Technology Data Exchange (ETDEWEB)
Endo, M [Ishikawajima-Harima Heavy Industries, Co. Ltd., Tokyo (Japan)
1994-05-01
The control unit of gas turbine for the aircraft jet engine use must draw overall performance in compliance with the thrust commanded by the pilot under all flying conditions of the engine. High reliability is required in flight safety. The present paper explains a developed unit of dual redundant FADEC (full authority digital electronic control) and high-density mounting technology for the electronic devices required by the FADEC. The FADEC unit is composed of two hardware systems with their respective microprocessors of the same structure. Each of both systems can solely control the engine, while they are both commanded by a necessary signal for the dual system operation and connected through a digital by-pass which can exchange the input/output data between them. For the operational confirmation of FADEC unit, its control characteristics were inspected by intentionally putting it out of order at the time of engine acceleration/deceleration and other transient operations. The control system could be switched without control characteristics lost of the engine. 9 figs., 2 tabs.
Bendell, A
1986-01-01
Software Reliability reviews some fundamental issues of software reliability as well as the techniques, models, and metrics used to predict the reliability of software. Topics covered include fault avoidance, fault removal, and fault tolerance, along with statistical methods for the objective assessment of predictive accuracy. Development cost models and life-cycle cost models are also discussed. This book is divided into eight sections and begins with a chapter on adaptive modeling used to predict software reliability, followed by a discussion on failure rate in software reliability growth mo
Recent Advances in Optimal Design of Structures from a Reliability Point of View
DEFF Research Database (Denmark)
Thoft-Christensen, Palle; Sørensen, John Dalsgaard
1987-01-01
-Christensen and Baker[4] and Madsen et al.[5]. Next a heuristic method, the so-called ß-unzipping method[6] is mentioned. This method can be used to estimate the reliability of a structural system if some modelling assumptions are fulfilled. In the third section some elements of structural optimisation theory...... section. First, a short review of the reliability theory for structural elements (e.g., beams and tubular joints) based on the so-called ß-index philosophy (Cornell[1], Ditlevsen[2], and Hasofer and Lind[3]) is given. Detailed descriptions are given in textbooks such as those by Thoft...
International Nuclear Information System (INIS)
Bidwell, S.W.; Radack, D.J.; Antonsen, T.M. Jr.; Booske, J.H.; Carmel, Y.; Destler, W.W.; Granatstein, V.L.; Levush, B.; Latham, P.E.; Zhang, Z.X.
1990-01-01
A high-average-power FEL amplifier operating at submillimeter frequencies is under development at the University of Maryland. Program goals are to produce a CW, ∼1 MW, FEL amplifier source at frequencies between 280 GHz and 560 GHz. To this end, a high-gain, high-efficiency, tapered FEL amplifier using a sheet electron beam and a short-period (superconducting) wiggler has been chosen. Development of this amplifier is progressing in three stages: (1) beam propagation through a long length (∼1 m) of short period (λ ω = 1 cm) wiggler, (2) demonstration of a proof-of-principle amplifier experiment at 98 GHz, and (3) designs of a superconducting tapered FEL amplifier meeting the ultimate design goal specifications. 17 refs., 1 fig., 1 tab
Bouman, Zita; Hendriks, Marc P H; Van Der Veld, William M; Aldenkamp, Albert P; Kessels, Roy P C
2016-06-01
The reliability and validity of three short forms of the Dutch version of the Wechsler Memory Scale-Fourth Edition (WMS-IV-NL) were evaluated in a mixed clinical sample of 235 patients. The short forms were based on the WMS-IV Flexible Approach, that is, a 3-subtest combination (Older Adult Battery for Adults) and two 2-subtest combinations (Logical Memory and Visual Reproduction and Logical Memory and Designs), which can be used to estimate the Immediate, Delayed, Auditory and Visual Memory Indices. All short forms showed good reliability coefficients. As expected, for adults (16-69 years old) the 3-subtest short form was consistently more accurate (predictive accuracy ranged from 73% to 100%) than both 2-subtest short forms (range = 61%-80%). Furthermore, for older adults (65-90 years old), the predictive accuracy of the 2-subtest short form ranged from 75% to 100%. These results suggest that caution is warranted when using the WMS-IV-NL Flexible Approach short forms to estimate all four indices. © The Author(s) 2015.
Evaluation of mobile ad hoc network reliability using propagation-based link reliability model
International Nuclear Information System (INIS)
Padmavathy, N.; Chaturvedi, Sanjay K.
2013-01-01
A wireless mobile ad hoc network (MANET) is a collection of solely independent nodes (that can move randomly around the area of deployment) making the topology highly dynamic; nodes communicate with each other by forming a single hop/multi-hop network and maintain connectivity in decentralized manner. MANET is modelled using geometric random graphs rather than random graphs because the link existence in MANET is a function of the geometric distance between the nodes and the transmission range of the nodes. Among many factors that contribute to the MANET reliability, the reliability of these networks also depends on the robustness of the link between the mobile nodes of the network. Recently, the reliability of such networks has been evaluated for imperfect nodes (transceivers) with binary model of communication links based on the transmission range of the mobile nodes and the distance between them. However, in reality, the probability of successful communication decreases as the signal strength deteriorates due to noise, fading or interference effects even up to the nodes' transmission range. Hence, in this paper, using a propagation-based link reliability model rather than a binary-model with nodes following a known failure distribution to evaluate the network reliability (2TR m , ATR m and AoTR m ) of MANET through Monte Carlo Simulation is proposed. The method is illustrated with an application and some imperative results are also presented
Neonatal overfeeding attenuates acute central pro-inflammatory effects of short-term high fat diet
Directory of Open Access Journals (Sweden)
Guohui eCai
2015-01-01
Full Text Available Neonatal obesity predisposes individuals to obesity throughout life. In rats, neonatal overfeeding also leads to early accelerated weight gain that persists into adulthood. The phenotype is associated with dysfunction in a number of systems including paraventricular nucleus of the hypothalamus (PVN responses to psychological and immune stressors. However, in many cases weight gain in neonatally overfed rats stabilizes in early adulthood so the animal does not become more obese as it ages. Here we examined if neonatal overfeeding by suckling rats in small litters predisposes them to exacerbated metabolic and central inflammatory disturbances if they are also given a high fat diet in later life. In adulthood we gave the rats normal chow, 3 days, or 3 weeks high fat diet (45% kcal from fat and measured peripheral indices of metabolic disturbance. We also investigated hypothalamic microglial changes, as an index of central inflammation, as well as PVN responses to lipopolysaccharide (LPS. Surprisingly, neonatal overfeeding did not predispose rats to the metabolic effects of a high fat diet. Weight changes and glucose metabolism were unaffected by the early life experience. However, short term (3 day high fat diet was associated with more microglia in the hypothalamus and a markedly exacerbated PVN response to LPS in control rats; effects not seen in the neonatally overfed. Our findings indicate neonatally overfed animals are not more susceptible to the adverse metabolic effects of a short-term high fat diet but may be less able to respond to the central effects.