WorldWideScience

Sample records for high quality reliable

  1. Quality and reliability management and its applications

    CERN Document Server

    2016-01-01

    Integrating development processes, policies, and reliability predictions from the beginning of the product development lifecycle to ensure high levels of product performance and safety, this book helps companies overcome the challenges posed by increasingly complex systems in today’s competitive marketplace.   Examining both research on and practical aspects of product quality and reliability management with an emphasis on applications, the book features contributions written by active researchers and/or experienced practitioners in the field, so as to effectively bridge the gap between theory and practice and address new research challenges in reliability and quality management in practice.    Postgraduates, researchers and practitioners in the areas of reliability engineering and management, amongst others, will find the book to offer a state-of-the-art survey of quality and reliability management and practices.

  2. The reliability-quality relationship for quality systems and quality risk management.

    Science.gov (United States)

    Claycamp, H Gregg; Rahaman, Faiad; Urban, Jason M

    2012-01-01

    Engineering reliability typically refers to the probability that a system, or any of its components, will perform a required function for a stated period of time and under specified operating conditions. As such, reliability is inextricably linked with time-dependent quality concepts, such as maintaining a state of control and predicting the chances of losses from failures for quality risk management. Two popular current good manufacturing practice (cGMP) and quality risk management tools, failure mode and effects analysis (FMEA) and root cause analysis (RCA) are examples of engineering reliability evaluations that link reliability with quality and risk. Current concepts in pharmaceutical quality and quality management systems call for more predictive systems for maintaining quality; yet, the current pharmaceutical manufacturing literature and guidelines are curiously silent on engineering quality. This commentary discusses the meaning of engineering reliability while linking the concept to quality systems and quality risk management. The essay also discusses the difference between engineering reliability and statistical (assay) reliability. The assurance of quality in a pharmaceutical product is no longer measured only "after the fact" of manufacturing. Rather, concepts of quality systems and quality risk management call for designing quality assurance into all stages of the pharmaceutical product life cycle. Interestingly, most assays for quality are essentially static and inform product quality over the life cycle only by being repeated over time. Engineering process reliability is the fundamental concept that is meant to anticipate quality failures over the life cycle of the product. Reliability is a well-developed theory and practice for other types of manufactured products and manufacturing processes. Thus, it is well known to be an appropriate index of manufactured product quality. This essay discusses the meaning of reliability and its linkages with quality

  3. Product quality, service reliability and management of operations at ...

    African Journals Online (AJOL)

    High product quality, service reliability, and management of operations are key factors in business growth and sustainability. Analyzing “The Starbucks Experience” is a pedagogical approach to reinforcing the concepts of control and management of quality, service reliability, and efficient operations in action. The objective ...

  4. Theory and practice of quality and reliability engineering in Asia industry

    CERN Document Server

    Goh, Thong

    2017-01-01

    This book discusses the application of quality and reliability engineering in Asian industries, and offers information for multinational companies (MNC) looking to transfer some of their operation and manufacturing capabilities to Asia and at the same time maintain high levels of reliability and quality. It is also provides small and medium enterprises (SME) in Asia with insights into producing high-quality and reliable products. It mainly comprises peer-reviewed papers that were presented at the Asian Network for Quality (ANQ) Congress 2014 held in Singapore (August, 2014), which provides a platform for companies, especially those within Asia where rapid changes and growth in manufacturing are taking place, to present their quality and reliability practices. The book presents practical demonstrations of how quality and reliability methodologies can be modified for the unique Asian market, and as such is a valuable resource for students, academics, professionals and practitioners in the field of quality and r...

  5. A reliable sewage quality abnormal event monitoring system.

    Science.gov (United States)

    Li, Tianling; Winnel, Melissa; Lin, Hao; Panther, Jared; Liu, Chang; O'Halloran, Roger; Wang, Kewen; An, Taicheng; Wong, Po Keung; Zhang, Shanqing; Zhao, Huijun

    2017-09-15

    With closing water loop through purified recycled water, wastewater becomes a part of source water, requiring reliable wastewater quality monitoring system (WQMS) to manage wastewater source and mitigate potential health risks. However, the development of reliable WQMS is fatally constrained by severe contamination and biofouling of sensors due to the hostile analytical environment of wastewaters, especially raw sewages, that challenges the limit of existing sensing technologies. In this work, we report a technological solution to enable the development of WQMS for real-time abnormal event detection with high reliability and practicality. A vectored high flow hydrodynamic self-cleaning approach and a dual-sensor self-diagnostic concept are adopted for WQMS to effectively encounter vital sensor failing issues caused by contamination and biofouling and ensure the integrity of sensing data. The performance of the WQMS has been evaluated over a 3-year trial period at different sewage catchment sites across three Australian states. It has demonstrated that the developed WQMS is capable of continuously operating in raw sewage for a prolonged period up to 24 months without maintenance and failure, signifying the high reliability and practicality. The demonstrated WQMS capability to reliably acquire real-time wastewater quality information leaps forward the development of effective wastewater source management system. The reported self-cleaning and self-diagnostic concepts should be applicable to other online water quality monitoring systems, opening a new way to encounter the common reliability and stability issues caused by sensor contamination and biofouling. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Quality assurance and reliability

    International Nuclear Information System (INIS)

    Normand, J.; Charon, M.

    1975-01-01

    Concern for obtaining high-quality products which will function properly when required to do so is nothing new - it is one manifestation of a conscientious attitude to work. However, the complexity and cost of equipment and the consequences of even temporary immobilization are such that it has become necessary to make special arrangements for obtaining high-quality products and examining what one has obtained. Each unit within an enterprise must examine its own work or arrange for it to be examined; a unit whose specific task is quality assurance is responsible for overall checking, but does not relieve other units of their responsibility. Quality assurance is a form of mutual assistance within an enterprise, designed to remove the causes of faults as far as possible. It begins very early in a project and continues through the ordering stage, construction, start-up trials and operation. Quality and hence reliability are the direct result of what is done at all stages of a project. They depend on constant attention to detail, for even a minor piece of poor workmanship can, in the case of an essential item of equipment, give rise to serious operational difficulties

  7. Introduction to quality and reliability engineering

    CERN Document Server

    Jiang, Renyan

    2015-01-01

    This book presents the state-of-the-art in quality and reliability engineering from a product life cycle standpoint. Topics in reliability include reliability models, life data analysis and modeling, design for reliability and accelerated life testing, while topics in quality include design for quality, acceptance sampling and supplier selection, statistical process control, production tests such as screening and burn-in, warranty and maintenance. The book provides comprehensive insights into two closely related subjects, and includes a wealth of examples and problems to enhance reader comprehension and link theory and practice. All numerical examples can be easily solved using Microsoft Excel. The book is intended for senior undergraduate and post-graduate students in related engineering and management programs such as mechanical engineering, manufacturing engineering, industrial engineering and engineering management programs, as well as for researchers and engineers in the quality and reliability fields. D...

  8. High-Reliability Health Care: Getting There from Here

    Science.gov (United States)

    Chassin, Mark R; Loeb, Jerod M

    2013-01-01

    Context Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer “project fatigue” because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. Methods We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals’ readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. Findings We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Conclusions Hospitals can make substantial progress toward high reliability by undertaking several specific

  9. Contribution to high voltage matrix switches reliability

    International Nuclear Information System (INIS)

    Lausenaz, Yvan

    2000-01-01

    Nowadays, power electronic equipment requirements are important, concerning performances, quality and reliability. On the other hand, costs have to be reduced in order to satisfy the market rules. To provide cheap, reliability and performances, many standard components with mass production are developed. But the construction of specific products must be considered following these two different points: in one band you can produce specific components, with delay, over-cost problems and eventuality quality and reliability problems, in the other and you can use standard components in a adapted topologies. The CEA of Pierrelatte has adopted this last technique of power electronic conception for the development of these high voltage pulsed power converters. The technique consists in using standard components and to associate them in series and in parallel. The matrix constitutes high voltage macro-switch where electrical parameters are distributed between the synchronized components. This study deals with the reliability of these structures. It brings up the high reliability aspect of MOSFETs matrix associations. Thanks to several homemade test facilities, we obtained lots of data concerning the components we use. The understanding of defects propagation mechanisms in matrix structures has allowed us to put forwards the necessity of robust drive system, adapted clamping voltage protection, and careful geometrical construction. All these reliability considerations in matrix associations have notably allowed the construction of a new matrix structure regrouping all solutions insuring reliability. Reliable and robust, this product has already reaches the industrial stage. (author) [fr

  10. High-reliability health care: getting there from here.

    Science.gov (United States)

    Chassin, Mark R; Loeb, Jerod M

    2013-09-01

    Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer "project fatigue" because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals' readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Hospitals can make substantial progress toward high reliability by undertaking several specific organizational change initiatives. Further research

  11. Reliability in perceptual analysis of voice quality.

    Science.gov (United States)

    Bele, Irene Velsvik

    2005-12-01

    This study focuses on speaking voice quality in male teachers (n = 35) and male actors (n = 36), who represent untrained and trained voice users, because we wanted to investigate normal and supranormal voices. In this study, both substantial and methodologic aspects were considered. It includes a method for perceptual voice evaluation, and a basic issue was rater reliability. A listening group of 10 listeners, 7 experienced speech-language therapists, and 3 speech-language therapist students evaluated the voices by 15 vocal characteristics using VA scales. Two sets of voice signals were investigated: text reading (2 loudness levels) and sustained vowel (3 levels). The results indicated a high interrater reliability for most perceptual characteristics. Connected speech was evaluated more reliably, especially at the normal level, but both types of voice signals were evaluated reliably, although the reliability for connected speech was somewhat higher than for vowels. Experienced listeners tended to be more consistent in their ratings than did the student raters. Some vocal characteristics achieved acceptable reliability even with a smaller panel of listeners. The perceptual characteristics grouped in 4 factors reflected perceptual dimensions.

  12. Memorial Hermann: high reliability from board to bedside.

    Science.gov (United States)

    Shabot, M Michael; Monroe, Douglas; Inurria, Juan; Garbade, Debbi; France, Anne-Claire

    2013-06-01

    In 2006 the Memorial Hermann Health System (MHHS), which includes 12 hospitals, began applying principles embraced by high reliability organizations (HROs). Three factors support its HRO journey: (1) aligned organizational structure with transparent management systems and compressed reporting processes; (2) Robust Process Improvement (RPI) with high-reliability interventions; and (3) cultural establishment, sustainment, and evolution. The Quality and Safety strategic plan contains three domains, each with a specific set of measures that provide goals for performance: (1) "Clinical Excellence;" (2) "Do No Harm;" and (3) "Saving Lives," as measured by the Serious Safety Event rate. MHHS uses a uniform approach to performance improvement--RPI, which includes Six Sigma, Lean, and change management, to solve difficult safety and quality problems. The 9 acute care hospitals provide multiple opportunities to integrate high-reliability interventions and best practices across MHHS. For example, MHHS partnered with the Joint Commission Center for Transforming Healthcare in its inaugural project to establish reliable hand hygiene behaviors, which improved MHHS's average hand hygiene compliance rate from 44% to 92% currently. Soon after compliance exceeded 85% at all 12 hospitals, the average rate of central line-associated bloodstream and ventilator-associated pneumonias decreased to essentially zero. MHHS's size and diversity require a disciplined approach to performance improvement and systemwide achievement of measurable success. The most significant cultural change at MHHS has been the expectation for 100% compliance with evidence-based quality measures and 0% incidence of patient harm.

  13. High Electricity Demand in the Northeast U.S.: PJM Reliability Network and Peaking Unit Impacts on Air Quality.

    Science.gov (United States)

    Farkas, Caroline M; Moeller, Michael D; Felder, Frank A; Henderson, Barron H; Carlton, Annmarie G

    2016-08-02

    On high electricity demand days, when air quality is often poor, regional transmission organizations (RTOs), such as PJM Interconnection, ensure reliability of the grid by employing peak-use electric generating units (EGUs). These "peaking units" are exempt from some federal and state air quality rules. We identify RTO assignment and peaking unit classification for EGUs in the Eastern U.S. and estimate air quality for four emission scenarios with the Community Multiscale Air Quality (CMAQ) model during the July 2006 heat wave. Further, we population-weight ambient values as a surrogate for potential population exposure. Emissions from electricity reliability networks negatively impact air quality in their own region and in neighboring geographic areas. Monitored and controlled PJM peaking units are generally located in economically depressed areas and can contribute up to 87% of hourly maximum PM2.5 mass locally. Potential population exposure to peaking unit PM2.5 mass is highest in the model domain's most populated cities. Average daily temperature and national gross domestic product steer peaking unit heat input. Air quality planning that capitalizes on a priori knowledge of local electricity demand and economics may provide a more holistic approach to protect human health within the context of growing energy needs in a changing world.

  14. Quality assurance/quality control, reliability and availability of nuclear power plants

    International Nuclear Information System (INIS)

    Kueffer, K.

    1981-01-01

    In a first part this lectures will present a survey on nuclear power production and plant performance in the Western World and discuss key parameters such as load factors and non-availability. Some main reasons for reliable performance of nuclear power plants are given. The second part of this lecture deals with the question how quality assurance and quality control measures do directly influence plant reliability, availability and, thus, economy. Derived from worldwide experience gained from operating nuclear power plants, it may be concluded that the implementation of an overall quality assurance programme does not only satisfy safety requirements set forth by the nuclear regulatory bodies, but has also a considerable impact on plant reliability and availability. A positive effect on these figures will be achieved if the established quality assurance programme provides for a coordinated approach to all activities affecting quality. It is discussed how the quality of a product should be controlled and what kind of quality assurance measures by performed examples are given to demonstrate that the expenditure for maintenance work on components will decrease if planned and systematic quality assurance actions have been implemented during all procurement stages. (orig./RW)

  15. Quality assurance and reliability in the Japanese electronics industry

    Science.gov (United States)

    Pecht, Michael; Boulton, William R.

    1995-02-01

    Quality and reliability are two attributes required for all Japanese products, although the JTEC panel found these attributes to be secondary to customer cost requirements. While our Japanese hosts gave presentations on the challenges of technology, cost, and miniaturization, quality and reliability were infrequently the focus of our discussions. Quality and reliability were assumed to be sufficient to meet customer needs. Fujitsu's slogan, 'quality built-in, with cost and performance as prime consideration,' illustrates this point. Sony's definition of a next-generation product is 'one that is going to be half the size and half the price at the same performance of the existing one'. Quality and reliability are so integral to Japan's electronics industry that they need no new emphasis.

  16. Achieving High Reliability with People, Processes, and Technology.

    Science.gov (United States)

    Saunders, Candice L; Brennan, John A

    2017-01-01

    High reliability as a corporate value in healthcare can be achieved by meeting the "Quadruple Aim" of improving population health, reducing per capita costs, enhancing the patient experience, and improving provider wellness. This drive starts with the board of trustees, CEO, and other senior leaders who ingrain high reliability throughout the organization. At WellStar Health System, the board developed an ambitious goal to become a top-decile health system in safety and quality metrics. To achieve this goal, WellStar has embarked on a journey toward high reliability and has committed to Lean management practices consistent with the Institute for Healthcare Improvement's definition of a high-reliability organization (HRO): one that is committed to the prevention of failure, early identification and mitigation of failure, and redesign of processes based on identifiable failures. In the end, a successful HRO can provide safe, effective, patient- and family-centered, timely, efficient, and equitable care through a convergence of people, processes, and technology.

  17. Simple and rapid preparation of [11C]DASB with high quality and reliability for routine applications

    International Nuclear Information System (INIS)

    Haeusler, D.; Mien, L.-K.; Nics, L.; Ungersboeck, J.; Philippe, C.; Lanzenberger, R.R.; Kletter, K.; Dudczak, R.; Mitterhauser, M.; Wadsak, W.

    2009-01-01

    [ 11 C]DASB combines all major prerequisites for a successful SERT-ligand, providing excellent biological properties and in-vivo behaviour. Thus, we aimed to establish a fully automated procedure for the synthesis and purification of [ 11 C]DASB with a high degree of reliability reducing the overall synthesis time while conserving high yields and purity. The optimized [ 11 C]DASB synthesis was applied in more than 60 applications with a very low failure rate (3.2%). We obtained yields up to 8.9 GBq (average 5.3±1.6 GBq). Radiochemical yields based on [ 11 C]CH 3 I, (corrected for decay) were 66.3±6.9% with a specific radioactivity (A s ) of 86.8±24.3 GBq/μmol (both at the end of synthesis, EOS). Time consumption was kept to a minimum, resulting in 43 min from end of bombardment to release of the product after quality control. Form our data, it is evident that the presented method can be implemented for routine preparations of [ 11 C]DASB with high reliability.

  18. [Study of the relationship between human quality and reliability].

    Science.gov (United States)

    Long, S; Wang, C; Wang, L i; Yuan, J; Liu, H; Jiao, X

    1997-02-01

    To clarify the relationship between human quality and reliability, 1925 experiments in 20 subjects were carried out to study the relationship between disposition character, digital memory, graphic memory, multi-reaction time and education level and simulated aircraft operation. Meanwhile, effects of task difficulty and enviromental factor on human reliability were also studied. The results showed that human quality can be predicted and evaluated through experimental methods. The better the human quality, the higher the human reliability.

  19. Quality and reliability control on assemblies

    International Nuclear Information System (INIS)

    Mueller, H.

    1976-01-01

    Taking as an example electronic assemblies in printed circuit board engineering, quality control during manufacture is dealt with. After giving a survey of four phases of quality and reliability control, some specific methods of quality control are dealt with by means of a flowchart, and by some examples the necessity and the success of these measures are shown. (RW) [de

  20. Simple and rapid preparation of [{sup 11}C]DASB with high quality and reliability for routine applications

    Energy Technology Data Exchange (ETDEWEB)

    Haeusler, D.; Mien, L.-K. [Department of Nuclear Medicine, PET, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Department of Pharmaceutical Technology and Biopharmaceutics, University of Vienna, A-1090 Vienna (Austria); Nics, L. [Department of Nuclear Medicine, PET, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Department of Nutritional Sciences, University of Vienna, A-1090 Vienna (Austria); Ungersboeck, J. [Department of Nuclear Medicine, PET, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Department of Inorganic Chemistry, University of Vienna, A-1090 Vienna (Austria); Philippe, C. [Department of Nuclear Medicine, PET, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Department of Pharmaceutical Technology and Biopharmaceutics, University of Vienna, A-1090 Vienna (Austria); Lanzenberger, R.R. [Department of Psychiatry and Psychotherapy, Medical University of Vienna, A-1090 Vienna (Austria); Kletter, K.; Dudczak, R. [Department of Nuclear Medicine, PET, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Mitterhauser, M. [Department of Nuclear Medicine, PET, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Department of Pharmaceutical Technology and Biopharmaceutics, University of Vienna, A-1090 Vienna (Austria); Hospital Pharmacy of the General Hospital of Vienna, A-1090 Vienna (Austria); Wadsak, W. [Department of Nuclear Medicine, PET, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Department of Inorganic Chemistry, University of Vienna, A-1090 Vienna (Austria)], E-mail: wolfgang.wadsak@meduniwien.ac.at

    2009-09-15

    [{sup 11}C]DASB combines all major prerequisites for a successful SERT-ligand, providing excellent biological properties and in-vivo behaviour. Thus, we aimed to establish a fully automated procedure for the synthesis and purification of [{sup 11}C]DASB with a high degree of reliability reducing the overall synthesis time while conserving high yields and purity. The optimized [{sup 11}C]DASB synthesis was applied in more than 60 applications with a very low failure rate (3.2%). We obtained yields up to 8.9 GBq (average 5.3{+-}1.6 GBq). Radiochemical yields based on [{sup 11}C]CH{sub 3}I, (corrected for decay) were 66.3{+-}6.9% with a specific radioactivity (A{sub s}) of 86.8{+-}24.3 GBq/{mu}mol (both at the end of synthesis, EOS). Time consumption was kept to a minimum, resulting in 43 min from end of bombardment to release of the product after quality control. Form our data, it is evident that the presented method can be implemented for routine preparations of [{sup 11}C]DASB with high reliability.

  1. Quality and reliability of technical systems. 2. rev. and enlarged ed.

    International Nuclear Information System (INIS)

    Birolini, A.

    1988-01-01

    The work comprises, besides the definition of fundamentals, mathematical methods and tables, a detailed compilation of theory, practice and management in the field of quality assurance and reliability. Complete chapters are dedicated in particular to the reliability analyses, selection and qualification of electronic components, maintenance analyses in the development phase, quality assurance of the software, reliability and availability of repairable visual display units, statistical quality control as well as the improvement of the quality and reliability in the production phase of electronic components. (DG) With 152 figs., 58 tabs., 92 examples [de

  2. The Mentalization-Based Therapy Adherence and Quality Scale (MBT-AQS): Reliability in a clinical setting

    DEFF Research Database (Denmark)

    Simonsen, Sebastian; Juul, Sophie; Kongerslev, Mickey

    2018-01-01

    The Mentalization-Based Treatment Adherence and Quality Scale (MBT-AQS) is a 17-item measure of treatment adherence and quality of individual mentalization-based therapy (MBT). Until now, reliability research on the scale has primarily been conducted by highly experienced raters from the Norwegian...... MBT therapists in a clinical setting following a brief one-day training course. The overall reliabilities for six raters were good for adherence (.67) and for quality (.62). Thus, the MBT-AQS was found to be an appropriate MBT adherence rating instrument with clinical and educational utility outside...... MBT Quality Lab who were part of its development. Hence, it can be questioned whether only experts in research settings can achieve satisfying levels of reliability on the scale. In this study, we investigated whether a satisfying level of reliability on the MBT-AQS could be obtained by experienced...

  3. Reliability of risk-adjusted outcomes for profiling hospital surgical quality.

    Science.gov (United States)

    Krell, Robert W; Hozain, Ahmed; Kao, Lillian S; Dimick, Justin B

    2014-05-01

    Quality improvement platforms commonly use risk-adjusted morbidity and mortality to profile hospital performance. However, given small hospital caseloads and low event rates for some procedures, it is unclear whether these outcomes reliably reflect hospital performance. To determine the reliability of risk-adjusted morbidity and mortality for hospital performance profiling using clinical registry data. A retrospective cohort study was conducted using data from the American College of Surgeons National Surgical Quality Improvement Program, 2009. Participants included all patients (N = 55,466) who underwent colon resection, pancreatic resection, laparoscopic gastric bypass, ventral hernia repair, abdominal aortic aneurysm repair, and lower extremity bypass. Outcomes included risk-adjusted overall morbidity, severe morbidity, and mortality. We assessed reliability (0-1 scale: 0, completely unreliable; and 1, perfectly reliable) for all 3 outcomes. We also quantified the number of hospitals meeting minimum acceptable reliability thresholds (>0.70, good reliability; and >0.50, fair reliability) for each outcome. For overall morbidity, the most common outcome studied, the mean reliability depended on sample size (ie, how high the hospital caseload was) and the event rate (ie, how frequently the outcome occurred). For example, mean reliability for overall morbidity was low for abdominal aortic aneurysm repair (reliability, 0.29; sample size, 25 cases per year; and event rate, 18.3%). In contrast, mean reliability for overall morbidity was higher for colon resection (reliability, 0.61; sample size, 114 cases per year; and event rate, 26.8%). Colon resection (37.7% of hospitals), pancreatic resection (7.1% of hospitals), and laparoscopic gastric bypass (11.5% of hospitals) were the only procedures for which any hospitals met a reliability threshold of 0.70 for overall morbidity. Because severe morbidity and mortality are less frequent outcomes, their mean

  4. Establishment of quality, reliability and design standards for low, medium, and high power microwave hybrid microcircuits

    Science.gov (United States)

    Robinson, E. A.

    1973-01-01

    Quality, reliability, and design standards for microwave hybrid microcircuits were established. The MSFC Standard 85M03926 for hybrid microcircuits was reviewed and modifications were generated for use with microwave hybrid microcircuits. The results for reliability tests of microwave thin film capacitors, transistors, and microwave circuits are presented. Twenty-two microwave receivers were tested for 13,500 unit hours. The result of 111,121 module burn-in and operating hours for an integrated solid state transceiver module is reported.

  5. Mathematical Methods in Survival Analysis, Reliability and Quality of Life

    CERN Document Server

    Huber, Catherine; Mesbah, Mounir

    2008-01-01

    Reliability and survival analysis are important applications of stochastic mathematics (probability, statistics and stochastic processes) that are usually covered separately in spite of the similarity of the involved mathematical theory. This title aims to redress this situation: it includes 21 chapters divided into four parts: Survival analysis, Reliability, Quality of life, and Related topics. Many of these chapters were presented at the European Seminar on Mathematical Methods for Survival Analysis, Reliability and Quality of Life in 2006.

  6. Health Service Quality Scale: Brazilian Portuguese translation, reliability and validity.

    Science.gov (United States)

    Rocha, Luiz Roberto Martins; Veiga, Daniela Francescato; e Oliveira, Paulo Rocha; Song, Elaine Horibe; Ferreira, Lydia Masako

    2013-01-17

    The Health Service Quality Scale is a multidimensional hierarchical scale that is based on interdisciplinary approach. This instrument was specifically created for measuring health service quality based on marketing and health care concepts. The aim of this study was to translate and culturally adapt the Health Service Quality Scale into Brazilian Portuguese and to assess the validity and reliability of the Brazilian Portuguese version of the instrument. We conducted a cross-sectional, observational study, with public health system patients in a Brazilian university hospital. Validity was assessed using Pearson's correlation coefficient to measure the strength of the association between the Brazilian Portuguese version of the instrument and the SERVQUAL scale. Internal consistency was evaluated using Cronbach's alpha coefficient; the intraclass (ICC) and Pearson's correlation coefficients were used for test-retest reliability. One hundred and sixteen consecutive postoperative patients completed the questionnaire. Pearson's correlation coefficient for validity was 0.20. Cronbach's alpha for the first and second administrations of the final version of the instrument were 0.982 and 0.986, respectively. For test-retest reliability, Pearson's correlation coefficient was 0.89 and ICC was 0.90. The culturally adapted, Brazilian Portuguese version of the Health Service Quality Scale is a valid and reliable instrument to measure health service quality.

  7. Health service quality scale: Brazilian Portuguese translation, reliability and validity

    Science.gov (United States)

    2013-01-01

    Background The Health Service Quality Scale is a multidimensional hierarchical scale that is based on interdisciplinary approach. This instrument was specifically created for measuring health service quality based on marketing and health care concepts. The aim of this study was to translate and culturally adapt the Health Service Quality Scale into Brazilian Portuguese and to assess the validity and reliability of the Brazilian Portuguese version of the instrument. Methods We conducted a cross-sectional, observational study, with public health system patients in a Brazilian university hospital. Validity was assessed using Pearson’s correlation coefficient to measure the strength of the association between the Brazilian Portuguese version of the instrument and the SERVQUAL scale. Internal consistency was evaluated using Cronbach’s alpha coefficient; the intraclass (ICC) and Pearson’s correlation coefficients were used for test-retest reliability. Results One hundred and sixteen consecutive postoperative patients completed the questionnaire. Pearson’s correlation coefficient for validity was 0.20. Cronbach's alpha for the first and second administrations of the final version of the instrument were 0.982 and 0.986, respectively. For test-retest reliability, Pearson’s correlation coefficient was 0.89 and ICC was 0.90. Conclusions The culturally adapted, Brazilian Portuguese version of the Health Service Quality Scale is a valid and reliable instrument to measure health service quality. PMID:23327598

  8. Achieving High Reliability Operations Through Multi-Program Integration

    Energy Technology Data Exchange (ETDEWEB)

    Holly M. Ashley; Ronald K. Farris; Robert E. Richards

    2009-04-01

    Over the last 20 years the Idaho National Laboratory (INL) has adopted a number of operations and safety-related programs which has each periodically taken its turn in the limelight. As new programs have come along there has been natural competition for resources, focus and commitment. In the last few years, the INL has made real progress in integrating all these programs and are starting to realize important synergies. Contributing to this integration are both collaborative individuals and an emerging shared vision and goal of the INL fully maturing in its high reliability operations. This goal is so powerful because the concept of high reliability operations (and the resulting organizations) is a masterful amalgam and orchestrator of the best of all the participating programs (i.e. conduct of operations, behavior based safety, human performance, voluntary protection, quality assurance, and integrated safety management). This paper is a brief recounting of the lessons learned, thus far, at the INL in bringing previously competing programs into harmony under the goal (umbrella) of seeking to perform regularly as a high reliability organization. In addition to a brief diagram-illustrated historical review, the authors will share the INL’s primary successes (things already effectively stopped or started) and the gaps yet to be bridged.

  9. High-Reliable PLC RTOS Development and RPS Structure Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, H. S.; Song, D. Y.; Sohn, D. S.; Kim, J. H. [Enersys Co., Daejeon (Korea, Republic of)

    2008-04-15

    One of the KNICS objectives is to develop a platform for Nuclear Power Plant(NPP) I and C(Instrumentation and Control) system, especially plant protection system. The developed platform is POSAFE-Q and this work supports the development of POSAFE-Q with the development of high-reliable real-time operating system(RTOS) and programmable logic device(PLD) software. Another KNICS objective is to develop safety I and C systems, such as Reactor Protection System(RPS) and Engineered Safety Feature-Component Control System(ESF-CCS). This work plays an important role in the structure analysis for RPS. Validation and verification(V and V) of the safety critical software is an essential work to make digital plant protection system highly reliable and safe. Generally, the reliability and safety of software based system can be improved by strict quality assurance framework including the software development itself. In other words, through V and V, the reliability and safety of a system can be improved and the development activities like software requirement specification, software design specification, component tests, integration tests, and system tests shall be appropriately documented for V and V.

  10. High-Reliable PLC RTOS Development and RPS Structure Analysis

    International Nuclear Information System (INIS)

    Sohn, H. S.; Song, D. Y.; Sohn, D. S.; Kim, J. H.

    2008-04-01

    One of the KNICS objectives is to develop a platform for Nuclear Power Plant(NPP) I and C(Instrumentation and Control) system, especially plant protection system. The developed platform is POSAFE-Q and this work supports the development of POSAFE-Q with the development of high-reliable real-time operating system(RTOS) and programmable logic device(PLD) software. Another KNICS objective is to develop safety I and C systems, such as Reactor Protection System(RPS) and Engineered Safety Feature-Component Control System(ESF-CCS). This work plays an important role in the structure analysis for RPS. Validation and verification(V and V) of the safety critical software is an essential work to make digital plant protection system highly reliable and safe. Generally, the reliability and safety of software based system can be improved by strict quality assurance framework including the software development itself. In other words, through V and V, the reliability and safety of a system can be improved and the development activities like software requirement specification, software design specification, component tests, integration tests, and system tests shall be appropriately documented for V and V.

  11. Power quality and reliability issues in a deregulated energy market

    International Nuclear Information System (INIS)

    Huggins, M.J.

    1999-01-01

    The challenge of maintaining power quality and reliability in Ontario's new competitive electricity market was the focus of this paper. The intention of Ontario's deregulation is to lower costs and give customers more power and choice. However, some fear that costs pressures may lead to poorer quality. This paper reviewed the causes, costs, and responsibilities, and made some suggestions concerning how customers can protect their interests as the market opens. It was suggested that in order to assure power quality, especially during the transition period, customers need to take care to design their systems and equipment to tolerate some quality variations. Conversely, utilities need to strive for at least minimum industry standards under most conditions. Contracts should be carefully crafted, with responsibilities for reliability and quality clearly stated. 2 refs

  12. The art of progressive censoring applications to reliability and quality

    CERN Document Server

    Balakrishnan, N

    2014-01-01

    This monograph offers a thorough and updated guide to the theory and methods of progressive censoring, an area that has experienced tremendous growth in recent years. Progressive censoring, originally proposed in the 1950s, is an efficient method of handling samples from industrial experiments involving lifetimes of units that have either failed or censored in a progressive fashion during the life test, with many practical applications to reliability and quality. Key topics and features: Data sets from the literature as well as newly simulated data sets are used to illustrate concepts throughout the text Emphasis on real-life applications to life testing, reliability, and quality control Discussion of parametric and nonparametric inference Coverage of experimental design with optimal progressive censoring The Art of Progressive Censoring is a valuable reference for graduate students, researchers, and practitioners in applied statistics, quality control, life testing, and reliability. With its accessible style...

  13. Fabrication of high-quality brazed joints

    International Nuclear Information System (INIS)

    Orlov, A.V.

    1980-01-01

    Problem of ensuring of joint high-quality when brazing different parts in power engineering is considered. To obtain high-quality joints it is necessary to correctly design brazed joint and to choose a gap width, overlap length and fillet radius; to clean up carefully the surfaces to be brazed and fix them properly one relative to another; to apply a solder so as to provide its flowing into the gap and sticking in it; to exactly regulate thermal conditions of brazing. High quality and reliability of brazed joints are ensured by the application of solders based on noble metals, and cheap solders based on nickel, manganese and copper. Joints brazed with nickel base solders may operate at temperatures as high as 888 deg C

  14. Assessing high reliability via Bayesian approach and accelerated tests

    International Nuclear Information System (INIS)

    Erto, Pasquale; Giorgio, Massimiliano

    2002-01-01

    Sometimes the assessment of very high reliability levels is difficult for the following main reasons: - the high reliability level of each item makes it impossible to obtain, in a reasonably short time, a sufficient number of failures; - the high cost of the high reliability items to submit to life tests makes it unfeasible to collect enough data for 'classical' statistical analyses. In the above context, this paper presents a Bayesian solution to the problem of estimation of the parameters of the Weibull-inverse power law model, on the basis of a limited number (say six) of life tests, carried out at different stress levels, all higher than the normal one. The over-stressed (i.e. accelerated) tests allow the use of experimental data obtained in a reasonably short time. The Bayesian approach enables one to reduce the required number of failures adding to the failure information the available a priori engineers' knowledge. This engineers' involvement conforms to the most advanced management policy that aims at involving everyone's commitment in order to obtain total quality. A Monte Carlo study of the non-asymptotic properties of the proposed estimators and a comparison with the properties of maximum likelihood estimators closes the work

  15. Planning and implementation of reliability/quality programs to energy plants

    International Nuclear Information System (INIS)

    Quenon, J.

    1986-01-01

    Quality Assurance principles have long been applied in part to many varied industrial enterprises. The advent of commercial nuclear power brought the evolution of a more comprehensive approach to the applications of quality assurance programs in this industry. However, the application philosophy was almost totally aimed at assuring the safety of the worker and the public. Recently, there has been a strong movement by industries and business in the U.S. and Europe to apply quality assurance in a more general way to assure overall reliability as well as safety. This paper describes an approach to enable management to not only make initial determinations of how to apply the elements of a reliability/quality assurance program, but how to continuously adjust the program to optimize the benefits that can be obtained

  16. X-real-time executive (X-RTE) an ultra-high reliable real-time executive for safety critical systems

    International Nuclear Information System (INIS)

    Suresh Babu, R.M.

    1995-01-01

    With growing number of application of computers in safety critical systems of nuclear plants there has been a need to assure high quality and reliability of the software used in these systems. One way to assure software quality is to use qualified software components. Since the safety systems and control systems are real-time systems there is a need for a real-time supervisory software to guarantee temporal response of the system. This report describes one such software package, called X-Real-Time Executive (or X-RTE), which was developed in Reactor Control Division, BARC. The report describes all the capabilities and unique features of X-RTE and compares it with a commercially available operating system. The features of X-RTE include pre-emptive scheduling, process synchronization, inter-process communication, multi-processor support, temporal support, debug facility, high portability, high reliability, high quality, and extensive documentation. Examples have been used very liberally to illustrate the underlying concepts. Besides, the report provides a brief description about the methods used, during the software development, to assure high quality and reliability of X-RTE. (author). refs., 11 figs., tabs

  17. Highly reliable TOFD UT Technique

    International Nuclear Information System (INIS)

    Acharya, G.D.; Trivedi, S.A.R.; Pai, K.B.

    2003-01-01

    The high performance of the time of flight diffraction technique (TOFD) with regard to the detection capabilities of weld defects such as crack, slag, lack of fusion has led to a rapidly increasing acceptance of the technique as a pre?service inspection tool. Since the early 1990s TOFD has been applied to several projects, where it replaced the commonly used radiographic testing. The use of TOM lead to major time savings during new build and replacement projects. At the same time the TOFD technique was used as base line inspection, which enables monitoring in the future for critical welds, but also provides documented evidence for life?time. The TOFD technique as the ability to detect and simultaneously size flows of nearly any orientation within the weld and heat affected zone. TOM is recognized as a reliable, proven technique for detection and sizing of defects and proven to be a time saver, resulting in shorter shutdown periods and construction project times. Thus even in cases where inspection price of TOFD per welds is higher, in the end it will result in significantly lower overall costs and improve quality. This paper deals with reliability, economy, acceptance criteria and field experience. It also covers comparative study between radiography technique Vs. TOFD. (Author)

  18. Inter-rater reliability of nursing home quality indicators in the U.S

    Directory of Open Access Journals (Sweden)

    Roy Jason

    2003-11-01

    Full Text Available Abstract Background In the US, Quality Indicators (QI's profiling and comparing the performance of hospitals, health plans, nursing homes and physicians are routinely published for consumer review. We report the results of the largest study of inter-rater reliability done on nursing home assessments which generate the data used to derive publicly reported nursing home quality indicators. Methods We sampled nursing homes in 6 states, selecting up to 30 residents per facility who were observed and assessed by research nurses on 100 clinical assessment elements contained in the Minimum Data Set (MDS and compared these with the most recent assessment in the record done by facility nurses. Kappa statistics were generated for all data items and derived for 22 QI's over the entire sample and for each facility. Finally, facilities with many QI's with poor Kappa levels were compared to those with many QI's with excellent Kappa levels on selected characteristics. Results A total of 462 facilities in 6 states were approached and 219 agreed to participate, yielding a response rate of 47.4%. A total of 5758 residents were included in the inter-rater reliability analyses, around 27.5 per facility. Patients resembled the traditional nursing home resident, only 43.9% were continent of urine and only 25.2% were rated as likely to be discharged within the next 30 days. Results of resident level comparative analyses reveal high inter-rater reliability levels (most items >.75. Using the research nurses as the "gold standard", we compared composite quality indicators based on their ratings with those based on facility nurses. All but two QI's have adequate Kappa levels and 4 QI's have average Kappa values in excess of .80. We found that 16% of participating facilities performed poorly (Kappa .75 on 12 or more QI's. No facility characteristics were related to reliability of the data on which Qis are based. Conclusion While a few QI's being used for public reporting

  19. Validation and reliability of the Turkish Utian Quality-of-Life Scale in postmenopausal women.

    Science.gov (United States)

    Abay, Halime; Kaplan, Sena

    2016-04-01

    There are a limited number of menopause-specific quality-of-life scales for the Turkish population. This study was conducted to evaluate the validity and reliability of the Turkish Utian Quality-of-Life Scale in postmenopausal women. The study group was comprised of 250 postmenopausal women who applied to a training and research hospital's menopause clinic in Turkey. A survey form and the Turkish Utian quality-of-Life Scale were used to collect data, and the Turkish version of Short Form-36 was used to evaluate reliability with an equivalent form. Language-validity, content-validity, and construct-validity methods were used to assess the validity of the scale, and Cronbach's α coefficient calculation and the equivalent-form reliability methods were used to assess the reliability of the scale. The Turkish Utian Quality-of-Life Scale was determined to be a valid and reliable instrument for measuring the quality of life of postmenopausal women. Confirmatory factor analysis demonstrates that the instrument fits well with 23 items and a four-factor model. The Cronbach's α coefficient for the quality-of-life domains were as follows: 0.88 overall, 0.79 health, 0.78 emotional, 0.76 sexual, and 0.75 occupational. Reliability of the instrument was confirmed through significant correlations between scores on the Turkish version of the Utian Quality-of-Life Scale and the Turkish version of the Short Form-36 (r = 0.745, P measuring quality of life during menopause.

  20. The vital role of manufacturing quality in the reliability of PV modules

    Science.gov (United States)

    Rusch, Peter

    2014-10-01

    The influence of manufacturing quality on the reliability of PV modules coming out of today's factories has been, and is still, under estimated among investors and buyers. The main reason is perception. Contrary to popular belief, PV modules are not a commodity. Module quality does differ among module brands. Certification alone does not guarantee the quality or reliability of a module. Cost reductions in manufacturing have unequivocally affected module quality. And the use of new, cheaper materials has had a measureable impact on module reliability. The need for meaningful manufacturing quality standards has been understood by the leading technical institutions and important industry players. The fact that most leading PV panel manufacturers have been certified according to ISO 9001 has led to some level of improvement and higher effectiveness. The new ISO 9001 PV QMS standards will be a major step in providing a tool to assess PV manufacturers' quality management systems. The current lack of sufficient standards has still got a negative influence on the quality of modules being installed today. Today every manufacturer builds their modules in their own way with little standardization or adherence to quality processes and methods, which are commonplace in other manufacturing industries. Although photovoltaic technology is to a great extent mature, the way modules are being produced has changed significantly over the past few years and it continues to change at a rapid pace. Investors, financiers and lenders stand the most to gain from PV systems over the long-term, but also the most to lose. Investors, developers, EPC, O&M and solar asset management companies must all manage manufacturing quality more proactively or they will face unexpected risks and failures down the road. Manufacturing quality deserves more transparency and attention, as it is a major driver of module performance and reliability. This paper will explain the benefits of good manufacturing

  1. [Reliability theory based on quality risk network analysis for Chinese medicine injection].

    Science.gov (United States)

    Li, Zheng; Kang, Li-Yuan; Fan, Xiao-Hui

    2014-08-01

    A new risk analysis method based upon reliability theory was introduced in this paper for the quality risk management of Chinese medicine injection manufacturing plants. The risk events including both cause and effect ones were derived in the framework as nodes with a Bayesian network analysis approach. It thus transforms the risk analysis results from failure mode and effect analysis (FMEA) into a Bayesian network platform. With its structure and parameters determined, the network can be used to evaluate the system reliability quantitatively with probabilistic analytical appraoches. Using network analysis tools such as GeNie and AgenaRisk, we are able to find the nodes that are most critical to influence the system reliability. The importance of each node to the system can be quantitatively evaluated by calculating the effect of the node on the overall risk, and minimization plan can be determined accordingly to reduce their influences and improve the system reliability. Using the Shengmai injection manufacturing plant of SZYY Ltd as a user case, we analyzed the quality risk with both static FMEA analysis and dynamic Bayesian Network analysis. The potential risk factors for the quality of Shengmai injection manufacturing were identified with the network analysis platform. Quality assurance actions were further defined to reduce the risk and improve the product quality.

  2. The contribution of quality assurance to safety and reliability in nuclear power plants

    International Nuclear Information System (INIS)

    Raisic, N.

    1978-01-01

    The potential contribution of quality assurance to nuclear power plant safety and reliability is analysed. An attempt is made to establish a relationship between quality and reliability. The reliability may be expressed in quantitative terms as ''the probability that an item will perform a required function for a stated period of time''. Quality, however, cannot be expressed in simple quantitative terms but only as a set of required properties which an item should have for a specific application. The achievement of quality and additional reliability objectives is a task of project activities such as design, construction, installation, operation, etc. The elements of a quality assurance system and its functions in nuclear power projects are presented in some detail. Confidence in plant quality, which should be a basis for the regulatory body issuing the construction permit or operation licence, should be based on the capability of quality assurance activities to prevent errors and correct deficiencies in nuclear power plants. An analysis is made of those errors in plant design, manufacture, construction and operation which contribute most frequently to plant outages. It is concluded that these errors can be avoided or corrected by strict adherence to quality assurance principles and by the efficient functioning of quality assurance systems. In fact, quality assurance may be considered an effective defence against common cause failures originating in errors in the design, manufacture, installation or operation of a nuclear power plant

  3. Systematic evaluation of the teaching qualities of Obstetrics and Gynecology faculty: reliability and validity of the SETQ tools.

    Directory of Open Access Journals (Sweden)

    Renée van der Leeuw

    Full Text Available BACKGROUND: The importance of effective clinical teaching for the quality of future patient care is globally understood. Due to recent changes in graduate medical education, new tools are needed to provide faculty with reliable and individualized feedback on their teaching qualities. This study validates two instruments underlying the System for Evaluation of Teaching Qualities (SETQ aimed at measuring and improving the teaching qualities of obstetrics and gynecology faculty. METHODS AND FINDINGS: This cross-sectional multi-center questionnaire study was set in seven general teaching hospitals and two academic medical centers in the Netherlands. Seventy-seven residents and 114 faculty were invited to complete the SETQ instruments in the duration of one month from September 2008 to September 2009. To assess reliability and validity of the instruments, we used exploratory factor analysis, inter-item correlation, reliability coefficient alpha and inter-scale correlations. We also compared composite scales from factor analysis to global ratings. Finally, the number of residents' evaluations needed per faculty for reliable assessments was calculated. A total of 613 evaluations were completed by 66 residents (85.7% response rate. 99 faculty (86.8% response rate participated in self-evaluation. Factor analysis yielded five scales with high reliability (Cronbach's alpha for residents' and faculty: learning climate (0.86 and 0.75, professional attitude (0.89 and 0.81, communication of learning goals (0.89 and 0.82, evaluation of residents (0.87 and 0.79 and feedback (0.87 and 0.86. Item-total, inter-scale and scale-global rating correlation coefficients were significant (P<0.01. Four to six residents' evaluations are needed per faculty (reliability coefficient 0.60-0.80. CONCLUSIONS: Both SETQ instruments were found reliable and valid for evaluating teaching qualities of obstetrics and gynecology faculty. Future research should examine improvement of

  4. Results of the EC research project REQUEST on software quality and reliability

    International Nuclear Information System (INIS)

    Kersken, M.; Saglietti, F.

    1990-01-01

    GRS work in software safety was mainly concerned with the qualitative assessment of software reliability and quality. As a supplement to these activities the work within the REQUEST project emphasized the quantitative determination of the respective parameters. The three-level quality model COQUAMO serves for the computation - and partly for the prediction - of quality factors during the software life cycle. PERFIDE controls the application of software reliability models during the test phase and in early operational life. Specific attention was paid to the assessment of fault-tolerant diverse software systems. (orig.) [de

  5. Capacity and reliability analyses with applications to power quality

    Science.gov (United States)

    Azam, Mohammad; Tu, Fang; Shlapak, Yuri; Kirubarajan, Thiagalingam; Pattipati, Krishna R.; Karanam, Rajaiah

    2001-07-01

    The deregulation of energy markets, the ongoing advances in communication networks, the proliferation of intelligent metering and protective power devices, and the standardization of software/hardware interfaces are creating a dramatic shift in the way facilities acquire and utilize information about their power usage. The currently available power management systems gather a vast amount of information in the form of power usage, voltages, currents, and their time-dependent waveforms from a variety of devices (for example, circuit breakers, transformers, energy and power quality meters, protective relays, programmable logic controllers, motor control centers). What is lacking is an information processing and decision support infrastructure to harness this voluminous information into usable operational and management knowledge to handle the health of their equipment and power quality, minimize downtime and outages, and to optimize operations to improve productivity. This paper considers the problem of evaluating the capacity and reliability analyses of power systems with very high availability requirements (e.g., systems providing energy to data centers and communication networks with desired availability of up to 0.9999999). The real-time capacity and margin analysis helps operators to plan for additional loads and to schedule repair/replacement activities. The reliability analysis, based on computationally efficient sum of disjoint products, enables analysts to decide the optimum levels of redundancy, aids operators in prioritizing the maintenance options for a given budget and monitoring the system for capacity margin. The resulting analytical and software tool is demonstrated on a sample data center.

  6. Management systems for high reliability organizations. Integration and effectiveness; Managementsysteme fuer Hochzuverlaessigkeitsorganisationen. Integration und Wirksamkeit

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, Michael

    2015-03-09

    The scope of the thesis is the development of a method for improvement of efficient integrated management systems for high reliability organizations (HRO). A comprehensive analysis of severe accident prevention is performed. Severe accident management, mitigation measures and business continuity management are not included. High reliability organizations are complex and potentially dynamic organization forms that can be inherently dangerous like nuclear power plants, offshore platforms, chemical facilities, large ships or large aircrafts. A recursive generic management system model (RGM) was development based on the following factors: systemic and cybernetic Asepcts; integration of different management fields, high decision quality, integration of efficient methods of safety and risk analysis, integration of human reliability aspects, effectiveness evaluation and improvement.

  7. Fix These First: How the World's Leading Companies Point the Way Toward High Reliability in the Military Health System.

    Science.gov (United States)

    Beauvais, Brad; Richter, Jason; Brezinski, Paul

    The 2014 Military Health System Review calls for healthcare system leaders to implement effective strategies used by other high-performing organizations. The authors state, " the [military health system] MHS can create an optimal healthcare environment that focuses on continuous quality improvement where every patient receives safe, high-quality care at all times" (Military Health System, 2014, p. 1). Although aspirational, the document does not specify how a highly reliable health system is developed or what systemic factors are necessary to sustain highly reliable performance. Our work seeks to address this gap and provide guidance to MHS leaders regarding how high-performing organizations develop exceptional levels of performance.The authors' expectation is that military medicine will draw on these lessons to enhance leadership, develop exceptional organizational cultures, onboard and engage employees, build customer loyalty, and improve quality of care. Leaders from other segments of the healthcare field likely will find this study valuable given the size of the military healthcare system (9.6 million beneficiaries), the United States' steady progression toward population-based health, and the increasing need for highly reliable systems and performance.

  8. Seeking high reliability in primary care: Leadership, tools, and organization.

    Science.gov (United States)

    Weaver, Robert R

    2015-01-01

    Leaders in health care increasingly recognize that improving health care quality and safety requires developing an organizational culture that fosters high reliability and continuous process improvement. For various reasons, a reliability-seeking culture is lacking in most health care settings. Developing a reliability-seeking culture requires leaders' sustained commitment to reliability principles using key mechanisms to embed those principles widely in the organization. The aim of this study was to examine how key mechanisms used by a primary care practice (PCP) might foster a reliability-seeking, system-oriented organizational culture. A case study approach was used to investigate the PCP's reliability culture. The study examined four cultural artifacts used to embed reliability-seeking principles across the organization: leadership statements, decision support tools, and two organizational processes. To decipher their effects on reliability, the study relied on observations of work patterns and the tools' use, interactions during morning huddles and process improvement meetings, interviews with clinical and office staff, and a "collective mindfulness" questionnaire. The five reliability principles framed the data analysis. Leadership statements articulated principles that oriented the PCP toward a reliability-seeking culture of care. Reliability principles became embedded in the everyday discourse and actions through the use of "problem knowledge coupler" decision support tools and daily "huddles." Practitioners and staff were encouraged to report unexpected events or close calls that arose and which often initiated a formal "process change" used to adjust routines and prevent adverse events from recurring. Activities that foster reliable patient care became part of the taken-for-granted routine at the PCP. The analysis illustrates the role leadership, tools, and organizational processes play in developing and embedding a reliable-seeking culture across an

  9. Using software metrics and software reliability models to attain acceptable quality software for flight and ground support software for avionic systems

    Science.gov (United States)

    Lawrence, Stella

    1992-01-01

    This paper is concerned with methods of measuring and developing quality software. Reliable flight and ground support software is a highly important factor in the successful operation of the space shuttle program. Reliability is probably the most important of the characteristics inherent in the concept of 'software quality'. It is the probability of failure free operation of a computer program for a specified time and environment.

  10. Exact reliability quantification of highly reliable systems with maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Bris, Radim, E-mail: radim.bris@vsb.c [VSB-Technical University Ostrava, Faculty of Electrical Engineering and Computer Science, Department of Applied Mathematics, 17. listopadu 15, 70833 Ostrava-Poruba (Czech Republic)

    2010-12-15

    When a system is composed of highly reliable elements, exact reliability quantification may be problematic, because computer accuracy is limited. Inaccuracy can be due to different aspects. For example, an error may be made when subtracting two numbers that are very close to each other, or at the process of summation of many very different numbers, etc. The basic objective of this paper is to find a procedure, which eliminates errors made by PC when calculations close to an error limit are executed. Highly reliable system is represented by the use of directed acyclic graph which is composed from terminal nodes, i.e. highly reliable input elements, internal nodes representing subsystems and edges that bind all of these nodes. Three admissible unavailability models of terminal nodes are introduced, including both corrective and preventive maintenance. The algorithm for exact unavailability calculation of terminal nodes is based on merits of a high-performance language for technical computing MATLAB. System unavailability quantification procedure applied to a graph structure, which considers both independent and dependent (i.e. repeatedly occurring) terminal nodes is based on combinatorial principle. This principle requires summation of a lot of very different non-negative numbers, which may be a source of an inaccuracy. That is why another algorithm for exact summation of such numbers is designed in the paper. The summation procedure uses benefits from a special number system with the base represented by the value 2{sup 32}. Computational efficiency of the new computing methodology is compared with advanced simulation software. Various calculations on systems from references are performed to emphasize merits of the methodology.

  11. Validity and reliability of the novel thyroid-specific quality of life questionnaire, ThyPRO

    DEFF Research Database (Denmark)

    Watt, Torquil; Hegedüs, Laszlo; Groenvold, Mogens

    2010-01-01

    Background Appropriate scale validity and internal consistency reliability have recently been documented for the new thyroid-specific quality of life (QoL) patient-reported outcome (PRO) measure for benign thyroid disorders, the ThyPRO. However, before clinical use, clinical validity and test......-retest reliability should be evaluated. Aim To investigate clinical ('known-groups') validity and test-retest reliability of the Danish version of the ThyPRO. Methods For each of the 13 ThyPRO scales, we defined groups expected to have high versus low scores ('known-groups'). The clinical validity (known......-groups validity) was evaluated by whether the ThyPRO scales could detect expected differences in a cross-sectional study of 907 thyroid patients. Test-retest reliability was evaluated by intra-class correlations of two responses to the ThyPRO 2 weeks apart in a subsample of 87 stable patients. Results On all 13...

  12. Development of the knee quality of life (KQoL-26) 26-item questionnaire: data quality, reliability, validity and responsiveness.

    Science.gov (United States)

    Garratt, Andrew M; Brealey, Stephen; Robling, Michael; Atwell, Chris; Russell, Ian; Gillespie, William; King, David

    2008-07-10

    This article describes the development and validation of a self-reported questionnaire, the KQoL-26, that is based on the views of patients with a suspected ligamentous or meniscal injury of the knee that assesses the impact of their knee problem on the quality of their lives. Patient interviews and focus groups were used to derive questionnaire content. The instrument was assessed for data quality, reliability, validity, and responsiveness using data from a randomised trial and patient survey about general practitioners' use of Magnetic Resonance Imaging for patients with a suspected ligamentous or meniscal injury. Interview and focus group data produced a 40-item questionnaire designed for self-completion. 559 trial patients and 323 survey patients responded to the questionnaire. Following principal components analysis and Rasch analysis, 26 items were found to contribute to three scales of knee-related quality of life: physical functioning, activity limitations, and emotional functioning. Item-total correlations ranged from 0.60-0.82. Cronbach's alpha and test retest reliability estimates were 0.91-0.94 and 0.80-0.93 respectively. Hypothesised correlations with the Lysholm Knee Scale, EQ-5D, SF-36 and knee symptom questions were evidence for construct validity. The instrument produced highly significant change scores for 65 trial patients indicating that their knee was a little or somewhat better at six months. The new instrument had higher effect sizes (range 0.86-1.13) and responsiveness statistics (range 1.50-2.13) than the EQ-5D and SF-36. The KQoL-26 has good evidence for internal reliability, test-retest reliability, validity and responsiveness, and is recommended for use in randomised trials and other evaluative studies of patients with a suspected ligamentous or meniscal injury.

  13. Development of the Knee Quality of Life (KQoL-26 26-item questionnaire: data quality, reliability, validity and responsiveness

    Directory of Open Access Journals (Sweden)

    Atwell Chris

    2008-07-01

    Full Text Available Abstract Background This article describes the development and validation of a self-reported questionnaire, the KQoL-26, that is based on the views of patients with a suspected ligamentous or meniscal injury of the knee that assesses the impact of their knee problem on the quality of their lives. Methods Patient interviews and focus groups were used to derive questionnaire content. The instrument was assessed for data quality, reliability, validity, and responsiveness using data from a randomised trial and patient survey about general practitioners' use of Magnetic Resonance Imaging for patients with a suspected ligamentous or meniscal injury. Results Interview and focus group data produced a 40-item questionnaire designed for self-completion. 559 trial patients and 323 survey patients responded to the questionnaire. Following principal components analysis and Rasch analysis, 26 items were found to contribute to three scales of knee-related quality of life: physical functioning, activity limitations, and emotional functioning. Item-total correlations ranged from 0.60–0.82. Cronbach's alpha and test retest reliability estimates were 0.91–0.94 and 0.80–0.93 respectively. Hypothesised correlations with the Lysholm Knee Scale, EQ-5D, SF-36 and knee symptom questions were evidence for construct validity. The instrument produced highly significant change scores for 65 trial patients indicating that their knee was a little or somewhat better at six months. The new instrument had higher effect sizes (range 0.86–1.13 and responsiveness statistics (range 1.50–2.13 than the EQ-5D and SF-36. Conclusion The KQoL-26 has good evidence for internal reliability, test-retest reliability, validity and responsiveness, and is recommended for use in randomised trials and other evaluative studies of patients with a suspected ligamentous or meniscal injury.

  14. Systematic evaluation of the teaching qualities of Obstetrics and Gynecology faculty: reliability and validity of the SETQ tools.

    Science.gov (United States)

    van der Leeuw, Renée; Lombarts, Kiki; Heineman, Maas Jan; Arah, Onyebuchi

    2011-05-03

    The importance of effective clinical teaching for the quality of future patient care is globally understood. Due to recent changes in graduate medical education, new tools are needed to provide faculty with reliable and individualized feedback on their teaching qualities. This study validates two instruments underlying the System for Evaluation of Teaching Qualities (SETQ) aimed at measuring and improving the teaching qualities of obstetrics and gynecology faculty. This cross-sectional multi-center questionnaire study was set in seven general teaching hospitals and two academic medical centers in the Netherlands. Seventy-seven residents and 114 faculty were invited to complete the SETQ instruments in the duration of one month from September 2008 to September 2009. To assess reliability and validity of the instruments, we used exploratory factor analysis, inter-item correlation, reliability coefficient alpha and inter-scale correlations. We also compared composite scales from factor analysis to global ratings. Finally, the number of residents' evaluations needed per faculty for reliable assessments was calculated. A total of 613 evaluations were completed by 66 residents (85.7% response rate). 99 faculty (86.8% response rate) participated in self-evaluation. Factor analysis yielded five scales with high reliability (Cronbach's alpha for residents' and faculty): learning climate (0.86 and 0.75), professional attitude (0.89 and 0.81), communication of learning goals (0.89 and 0.82), evaluation of residents (0.87 and 0.79) and feedback (0.87 and 0.86). Item-total, inter-scale and scale-global rating correlation coefficients were significant (Pteaching qualities of obstetrics and gynecology faculty. Future research should examine improvement of teaching qualities when using SETQ.

  15. Reliability of medical audit in quality assessment of medical care

    Directory of Open Access Journals (Sweden)

    Camacho Luiz Antonio Bastos

    1996-01-01

    Full Text Available Medical audit of hospital records has been a major component of quality of care assessment, although physician judgment is known to have low reliability. We estimated interrater agreement of quality assessment in a sample of patients with cardiac conditions admitted to an American teaching hospital. Physician-reviewers used structured review methods designed to improve quality assessment based on judgment. Chance-corrected agreement for the items considered more relevant to process and outcome of care ranged from low to moderate (0.2 to 0.6, depending on the review item and the principal diagnoses and procedures the patients underwent. Results from several studies seem to converge on this point. Comparisons among different settings should be made with caution, given the sensitivity of agreement measurements to prevalence rates. Reliability of review methods in their current stage could be improved by combining the assessment of two or more reviewers, and by emphasizing outcome-oriented events.

  16. Development of a highly reliable CRT processor

    International Nuclear Information System (INIS)

    Shimizu, Tomoya; Saiki, Akira; Hirai, Kenji; Jota, Masayoshi; Fujii, Mikiya

    1996-01-01

    Although CRT processors have been employed by the main control board to reduce the operator's workload during monitoring, the control systems are still operated by hardware switches. For further advancement, direct controller operation through a display device is expected. A CRT processor providing direct controller operation must be as reliable as the hardware switches are. The authors are developing a new type of highly reliable CRT processor that enables direct controller operations. In this paper, we discuss the design principles behind a highly reliable CRT processor. The principles are defined by studies of software reliability and of the functional reliability of the monitoring and operation systems. The functional configuration of an advanced CRT processor is also addressed. (author)

  17. Validity and reliability of the Portuguese-Brazilian version of the Quality of Life in Epilepsy Inventory-89.

    Science.gov (United States)

    Azevedo, Auro Mauro; Alonso, Neide Barreira; Vidal-Dourado, Marcos; Noffs, Maria Helena da Silva; Pascalicchio, Tatiana Frascarelli; Caboclo, Luís Otávio Sales Ferreira; Ciconelli, Rozana Mesquita; Sakamoto, Américo Ceiki; Yacubian, Elza Márcia Targas

    2009-03-01

    The purpose of this article was to report the translation of the Quality of Life in Epilepsy Inventory-89 (QOLIE-89) into a Portuguese-Brazilian version and evaluate its reliability and validity. This study involved 105 outpatients: 54 patients with refractory temporal lobe epilepsy (TLE) with mesial temporal sclerosis (MTS) and 51 with juvenile myoclonic epilepsy (JME). Reliability and test-retest reliability were assessed. Relationships between QOLIE-89 domains and other questionnaires (Nottingham Health Profile, Beck Depression Inventory, Adverse Event Profile, Neuropsychological Evaluation), and external measures such as demographic and clinical variables were analyzed to examine construct validity. Internal consistency (Cronbach's alpha=0.73-0.92) and test-retest reliability (intraclass correlation coefficient=0.60-0.84) for individual domains were acceptable. For construct validity, we verified high correlations between the QOLIE-89 and the Nottingham Health Profile, Beck Depression Inventory, Adverse Event Profile, and Neuropsychological Evaluation. For clinical characteristics, the patients with juvenile myoclonic epilepsy had better quality-of-life scores on 11 of 17 QOLIE-89 subscales compared with patients with temporal lobe epilepsy (P<0.05). These results support the reliability and validity of the Portuguese-Brazilian translation of QOLIE-89.

  18. Product reliability and the reliability of its emanating operational processes.

    NARCIS (Netherlands)

    Sonnemans, P.J.M.; Geudens, W.H.J.M.

    1999-01-01

    This paper addresses the problem of proper reliability management in business operations today, facing increasing demands on essential business drivers such as time to market, quality and financial profit. In this paper a general method is described of how to achieve product quality in a highly

  19. A New Tool for Nutrition App Quality Evaluation (AQEL): Development, Validation, and Reliability Testing.

    Science.gov (United States)

    DiFilippo, Kristen Nicole; Huang, Wenhao; Chapman-Novakofski, Karen M

    2017-10-27

    The extensive availability and increasing use of mobile apps for nutrition-based health interventions makes evaluation of the quality of these apps crucial for integration of apps into nutritional counseling. The goal of this research was the development, validation, and reliability testing of the app quality evaluation (AQEL) tool, an instrument for evaluating apps' educational quality and technical functionality. Items for evaluating app quality were adapted from website evaluations, with additional items added to evaluate the specific characteristics of apps, resulting in 79 initial items. Expert panels of nutrition and technology professionals and app users reviewed items for face and content validation. After recommended revisions, nutrition experts completed a second AQEL review to ensure clarity. On the basis of 150 sets of responses using the revised AQEL, principal component analysis was completed, reducing AQEL into 5 factors that underwent reliability testing, including internal consistency, split-half reliability, test-retest reliability, and interrater reliability (IRR). Two additional modifiable constructs for evaluating apps based on the age and needs of the target audience as selected by the evaluator were also tested for construct reliability. IRR testing using intraclass correlations (ICC) with all 7 constructs was conducted, with 15 dietitians evaluating one app. Development and validation resulted in the 51-item AQEL. These were reduced to 25 items in 5 factors after principal component analysis, plus 9 modifiable items in two constructs that were not included in principal component analysis. Internal consistency and split-half reliability of the following constructs derived from principal components analysis was good (Cronbach alpha >.80, Spearman-Brown coefficient >.80): behavior change potential, support of knowledge acquisition, app function, and skill development. App purpose split half-reliability was .65. Test-retest reliability showed no

  20. The Reliability of Quality of Upper Extremity Skills Test in Children with Cerebral Palsy

    Directory of Open Access Journals (Sweden)

    Nazila Akbar-Fahimi

    2012-01-01

    Full Text Available Objective: The aim of this study was to survey the reliability of Intra-rater and Inter-rater with and without video camera assessment in children with spastic cerebral palsy. Materials & Methods: In this cross-sectional study, we validate the Quality of Upper Extremity Skill Test questionnaire. Fifty children with hemiplegia aged 19 to 95 months (mean age 61.31 ± 25.7 month were enrolled in our study using non random available approach. After obtaining parents’ consent, intra-rater assessment was performed in one session and intera rater assessment with camera after 10 days. Then, the third examiner did the reassessment using film observation of 46 children from 50. Spearman correlation for survey the reliability of intra-rater & inter rater with & without video recording assessment & gross motor function classification system 66 for determined functionality of child were used. Results: Intra-rater correlation was 0.774-0.996, Inter-rater correlation was 0.663-0.998 and correlation for video camera assessment was 0.710-0.974 for the first and third evaluation and 0.652-0.938 for second and third evaluation. P value for sub scales and total score was P<0.01. Conclusion: There is a high correlation in Intra rater and inter rater assessment with and without video recording in Quality of Upper Extremity Skill Test in children with cerebral palsy. So that it can be used as a reliable test to evaluate Quality of Upper Extremity Skills in these children.

  1. Patient safety in anesthesia: learning from the culture of high-reliability organizations.

    Science.gov (United States)

    Wright, Suzanne M

    2015-03-01

    There has been an increased awareness of and interest in patient safety and improved outcomes, as well as a growing body of evidence substantiating medical error as a leading cause of death and injury in the United States. According to The Joint Commission, US hospitals demonstrate improvements in health care quality and patient safety. Although this progress is encouraging, much room for improvement remains. High-reliability organizations, industries that deliver reliable performances in the face of complex working environments, can serve as models of safety for our health care system until plausible explanations for patient harm are better understood. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Reliability, availability, and quality assurance considerations for fusion components

    International Nuclear Information System (INIS)

    Buende, R.

    1995-01-01

    The complexity of magnetic confinement machines has been a matter of concern in developing fusion power plants as electricity generating stations because it might reduce plant availability. A comprehensive reliability and availability (R and A) programme to determine the availability of a next step fusion machine was performed during definition and conceptual design of the Next European Torus. In addition to giving an overview of the expected contributions to unavailability of the various components, this activity identified the basic approach to be taken to specify and to achieve necessary improvements. This paper, after giving some basic definitions, describes the essentials of the R and A programme, its results, and the guidelines derived for further work towards a sufficiently reliable fusion plant. These guidelines refer to improvement of the reliability database and the quality assurance to be performed at the design stage of a next step machine. (orig.)

  3. Supply reliability in context to quality regulation. Forecast model for the supply reliability; Versorgungszuverlaessigkeit im Kontext der Qualitaetsregulierung. Prognosemodell fuer die Versorgungszuverlaessigkeit

    Energy Technology Data Exchange (ETDEWEB)

    Quadflieg, Dieter [VDE, Berlin (Germany). FNN-Projektgruppe ' ' Einflussgroessen auf die Versorgungszuverlaessigkeit' '

    2011-11-14

    The forum network technology / network operations in VDE (FNN) has published a technical note on supply reliability in the context of quality regulation. In the underlying investigations, on the one hand the influencing variables on the supply reliability are analyzed on the basis of FNN fault and availability statistics. On the other stochastic methods are developed that allow a prediction of the stochastic reliability characteristics of each network operator.

  4. Development of a quality-assessment tool for experimental bruxism studies: reliability and validity.

    Science.gov (United States)

    Dawson, Andreas; Raphael, Karen G; Glaros, Alan; Axelsson, Susanna; Arima, Taro; Ernberg, Malin; Farella, Mauro; Lobbezoo, Frank; Manfredini, Daniele; Michelotti, Ambra; Svensson, Peter; List, Thomas

    2013-01-01

    To combine empirical evidence and expert opinion in a formal consensus method in order to develop a quality-assessment tool for experimental bruxism studies in systematic reviews. Tool development comprised five steps: (1) preliminary decisions, (2) item generation, (3) face-validity assessment, (4) reliability and discriminitive validity assessment, and (5) instrument refinement. The kappa value and phi-coefficient were calculated to assess inter-observer reliability and discriminative ability, respectively. Following preliminary decisions and a literature review, a list of 52 items to be considered for inclusion in the tool was compiled. Eleven experts were invited to join a Delphi panel and 10 accepted. Four Delphi rounds reduced the preliminary tool-Quality-Assessment Tool for Experimental Bruxism Studies (Qu-ATEBS)- to 8 items: study aim, study sample, control condition or group, study design, experimental bruxism task, statistics, interpretation of results, and conflict of interest statement. Consensus among the Delphi panelists yielded good face validity. Inter-observer reliability was acceptable (k = 0.77). Discriminative validity was excellent (phi coefficient 1.0; P reviews of experimental bruxism studies, exhibits face validity, excellent discriminative validity, and acceptable inter-observer reliability. Development of quality assessment tools for many other topics in the orofacial pain literature is needed and may follow the described procedure.

  5. Reliability and Failure in NASA Missions: Blunders, Normal Accidents, High Reliability, Bad Luck

    Science.gov (United States)

    Jones, Harry W.

    2015-01-01

    NASA emphasizes crew safety and system reliability but several unfortunate failures have occurred. The Apollo 1 fire was mistakenly unanticipated. After that tragedy, the Apollo program gave much more attention to safety. The Challenger accident revealed that NASA had neglected safety and that management underestimated the high risk of shuttle. Probabilistic Risk Assessment was adopted to provide more accurate failure probabilities for shuttle and other missions. NASA's "faster, better, cheaper" initiative and government procurement reform led to deliberately dismantling traditional reliability engineering. The Columbia tragedy and Mars mission failures followed. Failures can be attributed to blunders, normal accidents, or bad luck. Achieving high reliability is difficult but possible.

  6. Study on application of a high-speed trigger-type SFCL (TSFCL) for interconnection of power systems with different reliabilities

    International Nuclear Information System (INIS)

    Kim, Hye Ji; Yoon, Yong Tae

    2016-01-01

    Highlights: • Application of TSFCL to interconnect systems with different reliabilities is proposed. • TSFCL protects a grid by preventing detrimental effects from being delivered through the interconnection line. • A high-speed TSFCL with high impedance for transmission systems is required to be developed. - Abstract: Interconnection of power systems is one effective way to improve power supply reliability. However, differences in the reliability of each power system create a greater obstacle for the stable interconnection of power systems, as after interconnection a high-reliability system is affected by frequent faults in low reliability side systems. Several power system interconnection methods, such as the back-to-back method and the installation of either transformers or series reactors, have been investigated to counteract the damage caused by faults in the other neighboring systems. However, these methods are uneconomical and require complex operational management plans. In this work, a high-speed trigger-type superconducting fault current limiter (TSFCL) with large-impedance is proposed as a solution to maintain reliability and power quality when a high reliability power system is interconnected with a low reliability power system. Through analysis of the reliability index for the numerical examples obtained from a PSCAD/EMTDC simulator, a high-speed TSFCL with a large-impedance is confirmed to be effective for the interconnection between power systems with different reliabilities.

  7. History of Reliability and Quality Assurance at Kennedy Space Center

    Science.gov (United States)

    Childers, Frank M.

    2004-01-01

    This Kennedy Historical Document (KHD) provides a unique historical perspective of the organizational and functional responsibilities for the manned and un-manned programs at Kennedy Space Center, Florida. As systems become more complex and hazardous, the attention to detailed planning and execution continues to be a challenge. The need for a robust reliability and quality assurance program will always be a necessity to ensure mission success. As new space missions are defined and technology allows for continued access to space, these programs cannot be compromised. The organizational structure that has provided the reliability and quality assurance functions for both the manned and unmanned programs has seen many changes since the first group came to Florida in the 1950's. The roles of government and contractor personnel have changed with each program and organizational alignment has changed based on that responsibility. The organizational alignment of the personnel performing these functions must ensure independent assessment of the processes.

  8. Quality and Reliability of Large-Eddy Simulations II

    CERN Document Server

    Salvetti, Maria Vittoria; Meyers, Johan; Sagaut, Pierre

    2011-01-01

    The second Workshop on "Quality and Reliability of Large-Eddy Simulations", QLES2009, was held at the University of Pisa from September 9 to September 11, 2009. Its predecessor, QLES2007, was organized in 2007 in Leuven (Belgium). The focus of QLES2009 was on issues related to predicting, assessing and assuring the quality of LES. The main goal of QLES2009 was to enhance the knowledge on error sources and on their interaction in LES and to devise criteria for the prediction and optimization of simulation quality, by bringing together mathematicians, physicists and engineers and providing a platform specifically addressing these aspects for LES. Contributions were made by leading experts in the field. The present book contains the written contributions to QLES2009 and is divided into three parts, which reflect the main topics addressed at the workshop: (i) SGS modeling and discretization errors; (ii) Assessment and reduction of computational errors; (iii) Mathematical analysis and foundation for SGS modeling.

  9. Quantitative and Qualitative Responses to Topical Cold in Healthy Caucasians Show Variance between Individuals but High Test-Retest Reliability.

    Directory of Open Access Journals (Sweden)

    Penny Moss

    Full Text Available Increased sensitivity to cold may be a predictor of persistent pain, but cold pain threshold is often viewed as unreliable. This study aimed to determine the within-subject reliability and between-subject variance of cold response, measured comprehensively as cold pain threshold plus pain intensity and sensation quality at threshold. A test-retest design was used over three sessions, one day apart. Response to cold was assessed at four sites (thenar eminence, volar forearm, tibialis anterior, plantar foot. Cold pain threshold was measured using a Medoc thermode and standard method of limits. Intensity of pain at threshold was rated using a 10cm visual analogue scale. Quality of sensation at threshold was quantified with indices calculated from subjects' selection of descriptors from a standard McGill Pain Questionnaire. Within-subject reliability for each measure was calculated with intra-class correlation coefficients and between-subject variance was evaluated as group coefficient of variation percentage (CV%. Gender and site comparisons were also made. Forty-five healthy adults participated: 20 male, 25 female; mean age 29 (range 18-56 years. All measures at all four test sites showed high within-subject reliability: cold pain thresholds r = 0.92-0.95; pain rating r = 0.93-0.97; McGill pain quality indices r = 0.87-0.85. In contrast, all measures showed wide between-subject variance (CV% between 51.4% and 92.5%. Upper limb sites were consistently more sensitive than lower limb sites, but equally reliable. Females showed elevated cold pain thresholds, although similar pain intensity and quality to males. Females were also more reliable and showed lower variance for all measures. Thus, although there was clear population variation, response to cold for healthy individuals was found to be highly reliable, whether measured as pain threshold, pain intensity or sensation quality. A comprehensive approach to cold response testing therefore may add

  10. Quantitative and Qualitative Responses to Topical Cold in Healthy Caucasians Show Variance between Individuals but High Test-Retest Reliability.

    Science.gov (United States)

    Moss, Penny; Whitnell, Jasmine; Wright, Anthony

    2016-01-01

    Increased sensitivity to cold may be a predictor of persistent pain, but cold pain threshold is often viewed as unreliable. This study aimed to determine the within-subject reliability and between-subject variance of cold response, measured comprehensively as cold pain threshold plus pain intensity and sensation quality at threshold. A test-retest design was used over three sessions, one day apart. Response to cold was assessed at four sites (thenar eminence, volar forearm, tibialis anterior, plantar foot). Cold pain threshold was measured using a Medoc thermode and standard method of limits. Intensity of pain at threshold was rated using a 10cm visual analogue scale. Quality of sensation at threshold was quantified with indices calculated from subjects' selection of descriptors from a standard McGill Pain Questionnaire. Within-subject reliability for each measure was calculated with intra-class correlation coefficients and between-subject variance was evaluated as group coefficient of variation percentage (CV%). Gender and site comparisons were also made. Forty-five healthy adults participated: 20 male, 25 female; mean age 29 (range 18-56) years. All measures at all four test sites showed high within-subject reliability: cold pain thresholds r = 0.92-0.95; pain rating r = 0.93-0.97; McGill pain quality indices r = 0.87-0.85. In contrast, all measures showed wide between-subject variance (CV% between 51.4% and 92.5%). Upper limb sites were consistently more sensitive than lower limb sites, but equally reliable. Females showed elevated cold pain thresholds, although similar pain intensity and quality to males. Females were also more reliable and showed lower variance for all measures. Thus, although there was clear population variation, response to cold for healthy individuals was found to be highly reliable, whether measured as pain threshold, pain intensity or sensation quality. A comprehensive approach to cold response testing therefore may add validity and

  11. How reliable are Functional Movement Screening scores? A systematic review of rater reliability.

    Science.gov (United States)

    Moran, Robert W; Schneiders, Anthony G; Major, Katherine M; Sullivan, S John

    2016-05-01

    Several physical assessment protocols to identify intrinsic risk factors for injury aetiology related to movement quality have been described. The Functional Movement Screen (FMS) is a standardised, field-expedient test battery intended to assess movement quality and has been used clinically in preparticipation screening and in sports injury research. To critically appraise and summarise research investigating the reliability of scores obtained using the FMS battery. Systematic literature review. Systematic search of Google Scholar, Scopus (including ScienceDirect and PubMed), EBSCO (including Academic Search Complete, AMED, CINAHL, Health Source: Nursing/Academic Edition), MEDLINE and SPORTDiscus. Studies meeting eligibility criteria were assessed by 2 reviewers for risk of bias using the Quality Appraisal of Reliability Studies checklist. Overall quality of evidence was determined using van Tulder's levels of evidence approach. 12 studies were appraised. Overall, there was a 'moderate' level of evidence in favour of 'acceptable' (intraclass correlation coefficient ≥0.6) inter-rater and intra-rater reliability for composite scores derived from live scoring. For inter-rater reliability of composite scores derived from video recordings there was 'conflicting' evidence, and 'limited' evidence for intra-rater reliability. For inter-rater reliability based on live scoring of individual subtests there was 'moderate' evidence of 'acceptable' reliability (κ≥0.4) for 4 subtests (Deep Squat, Shoulder Mobility, Active Straight-leg Raise, Trunk Stability Push-up) and 'conflicting' evidence for the remaining 3 (Hurdle Step, In-line Lunge, Rotary Stability). This review found 'moderate' evidence that raters can achieve acceptable levels of inter-rater and intra-rater reliability of composite FMS scores when using live ratings. Overall, there were few high-quality studies, and the quality of several studies was impacted by poor study reporting particularly in relation to

  12. Space Shuttle Program Primary Avionics Software System (PASS) Success Legacy - Quality and Reliability Date

    Science.gov (United States)

    Orr, James K.; Peltier, Daryl

    2010-01-01

    Thsi slide presentation reviews the avionics software system on board the space shuttle, with particular emphasis on the quality and reliability. The Primary Avionics Software System (PASS) provides automatic and fly-by-wire control of critical shuttle systems which executes in redundant computers. Charts given show the number of space shuttle flights vs time, PASS's development history, and other charts that point to the reliability of the system's development. The reliability of the system is also compared to predicted reliability.

  13. The role of quality tools in assessing reliability of the internet for health information.

    Science.gov (United States)

    Hanif, Faisal; Read, Janet C; Goodacre, John A; Chaudhry, Afzal; Gibbs, Paul

    2009-12-01

    The Internet has made it possible for patients and their families to access vast quantities of information that previously would have been difficult for anyone but a physician or librarian to obtain. Health information websites, however, are recognised to differ widely in quality and reliability of their content. This has led to the development of various codes of conduct or quality rating tools to assess the quality of health websites. However, the validity and reliability of these quality tools and their applicability to different health websites also varies. In principle, rating tools should be available to consumers, require a limited number of elements to be assessed, be assessable in all elements, be readable and be able to gauge the readability and consistency of information provided from a patient's view point. This article reviews the literature on the trends of the Internet use for health and analyses various codes of conduct/ethics or 'quality tools' available to monitor the quality of health websites from a patient perspective.

  14. High power klystrons for efficient reliable high power amplifiers

    Science.gov (United States)

    Levin, M.

    1980-11-01

    This report covers the design of reliable high efficiency, high power klystrons which may be used in both existing and proposed troposcatter radio systems. High Power (10 kW) klystron designs were generated in C-band (4.4 GHz to 5.0 GHz), S-band (2.5 GHz to 2.7 GHz), and L-band or UHF frequencies (755 MHz to 985 MHz). The tubes were designed for power supply compatibility and use with a vapor/liquid phase heat exchanger. Four (4) S-band tubes were developed in the course of this program along with two (2) matching focusing solenoids and two (2) heat exchangers. These tubes use five (5) tuners with counters which are attached to the focusing solenoids. A reliability mathematical model of the tube and heat exchanger system was also generated.

  15. The Toronto outcome measure for craniofacial prosthetics: reliability and validity of a condition-specific quality-of-life instrument.

    Science.gov (United States)

    Anderson, James D; Johnston, Dennis A; Haugh, Gil S; Kiat-Amnuay, Sudarat; Gettleman, Lawrence

    2013-01-01

    The purpose of this study was to refine the Toronto Outcome Measure for Craniofacial Prosthetics (TOMCP), present evidence for its reliability and validity, and use the instrument to explore differences in quality of life between prostheses made with chlorinated polyethylene (CPE) (experimental) and silicone (control). As part of a multicenter prospective controlled randomized double-blind single-crossover clinical trial of the two materials, the TOMCP was administered at the start and end of two 4-month study arms, during which 42 patients wore prostheses made from one material then the other. Reliability was assessed at the crossover. To determine validity of the TOMCP, the Linear Analogue Self-Assessment (LASA-12) and the Short-Form 8 (SF-8) were also administered with the TOMCP. The TOMCP was reduced by removing items that were unreliable, had poorly distributed answers, showed increased internal consistency after their removal, or were too highly correlated with more than one other item. The tests of reliability and validity were then repeated. Finally, the reduced instrument was used to test for differences in quality of life between prostheses made of the two materials. The item reduction tactics pared the 52-item instrument down to 27 items. The correlations of both TOMCP versions with the LASA-12 and the SF-8 were found to be statistically significant, providing evidence of the validity of the TOMCP. The instrument revealed significantly better quality of life with silicone rather than CPE prostheses. Both versions of the TOMCP were found to be reliable and valid. The instrument was able to show differences in quality of life between two materials.

  16. Towards high-reliability organising in healthcare: a strategy for building organisational capacity.

    Science.gov (United States)

    Aboumatar, Hanan J; Weaver, Sallie J; Rees, Dianne; Rosen, Michael A; Sawyer, Melinda D; Pronovost, Peter J

    2017-08-01

    In a high-reliability organisation (HRO), safety and quality (SQ) is an organisational priority, and all workforce members are engaged, continuously learning and improving their work. To build organisational capacity for SQ work, we have developed a role-tailored capacity-building framework that we are currently employing at the Johns Hopkins Armstrong Institute for Patient Safety and Quality as part of an organisational strategy towards HRO. This framework considers organisation-wide competencies for SQ that includes all staff and faculty and is integrated into a broader organisation-wide operating management system for improving quality. In this framework, achieving safe, high-quality care is connected to healthcare workforce preparedness. Capacity-building efforts are tailored to the needs of distinct groups within the workforce that fall within three categories: (1) front-line providers and staff, (2) managers and local improvement personnel and (3) SQ leaders and experts. In this paper we describe this framework, our implementation efforts to date, challenges met and lessons learnt. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  17. Quality assurance requirements for the reliability of nuclear power plants in developing countries

    International Nuclear Information System (INIS)

    Bhutta, S.M.

    1978-01-01

    Quality Assurance (QA) has not been taken very seriously in developing countries despite their having significant nuclear power programmes. This may affect plant reliability and demands that urgent and serious attention be given to the development and implementation of Quality Assurance programmes according to local conditions. Confusion has been created by the differences in definitions and interpretations of terminologies of Quality Assurance and Control. Problems have been aggravated by the lack of clearly defined responsibilities and accountabilities during the projects execution phases of site selection, data collection, design, equipment fabrication and construction, etc. Therefore, reliability of nuclear power plants in developing countries is relatively low. But whenever some programme of QA has been implemented it has helped to improve the plant performance. This is highlighted in this paper by the practical examples for the experience of Karachi Nuclear Power Plant whose forced outages have been reduced by over a half within a period of 3 years. In view of the benefits, a QA programme for Chashma Nuclear Power Project has also been initiated. In this paper urgency is emphasized for the establishment and implementation of a formal QA programme in the developing countries if the reactor suppliers and purchasers both want to ensure higher reliability of their plants. The best way that management can play its role effectively is by setting up a strong QA organization with local personnel, thus helping to attain self-reliance and higher reliability during plant operation. (author)

  18. Reliability testing of the Danish version of the Kidney Disease Quality of Life Short Form

    DEFF Research Database (Denmark)

    Molsted, Stig; Heaf, James; Prescott, Lotte

    2005-01-01

    . MATERIAL AND METHODS: Translation into Danish and back-translation into English were performed. Pilot, field and internal consistency reliability tests were performed. RESULTS: Cronbach's alpha coefficients for the internal reliability test ranged from 0.77 to 0.93 for the eight generic scales. In a test......OBJECTIVE: The questionnaire Kidney Disease Quality of Life Short Form version 1.3 (KDQOL-SF) is valuable for assessing the health-related quality of life in patients treated with chronic dialysis. The aim of this study was to translate and test the reliability of the KDQOL-SF for use in Denmark...... involving all patients, two of the disease-specific scales had Cronbach's alpha coefficients of test of the scores...

  19. Environmental education curriculum evaluation questionnaire: A reliability and validity study

    Science.gov (United States)

    Minner, Daphne Diane

    The intention of this research project was to bridge the gap between social science research and application to the environmental domain through the development of a theoretically derived instrument designed to give educators a template by which to evaluate environmental education curricula. The theoretical base for instrument development was provided by several developmental theories such as Piaget's theory of cognitive development, Developmental Systems Theory, Life-span Perspective, as well as curriculum research within the area of environmental education. This theoretical base fueled the generation of a list of components which were then translated into a questionnaire with specific questions relevant to the environmental education domain. The specific research question for this project is: Can a valid assessment instrument based largely on human development and education theory be developed that reliably discriminates high, moderate, and low quality in environmental education curricula? The types of analyses conducted to answer this question were interrater reliability (percent agreement, Cohen's Kappa coefficient, Pearson's Product-Moment correlation coefficient), test-retest reliability (percent agreement, correlation), and criterion-related validity (correlation). Face validity and content validity were also assessed through thorough reviews. Overall results indicate that 29% of the questions on the questionnaire demonstrated a high level of interrater reliability and 43% of the questions demonstrated a moderate level of interrater reliability. Seventy-one percent of the questions demonstrated a high test-retest reliability and 5% a moderate level. Fifty-five percent of the questions on the questionnaire were reliable (high or moderate) both across time and raters. Only eight questions (8%) did not show either interrater or test-retest reliability. The global overall rating of high, medium, or low quality was reliable across both coders and time, indicating

  20. Measurement of the Inter-Rater Reliability Rate Is Mandatory for Improving the Quality of a Medical Database: Experience with the Paulista Lung Cancer Registry.

    Science.gov (United States)

    Lauricella, Leticia L; Costa, Priscila B; Salati, Michele; Pego-Fernandes, Paulo M; Terra, Ricardo M

    2018-06-01

    Database quality measurement should be considered a mandatory step to ensure an adequate level of confidence in data used for research and quality improvement. Several metrics have been described in the literature, but no standardized approach has been established. We aimed to describe a methodological approach applied to measure the quality and inter-rater reliability of a regional multicentric thoracic surgical database (Paulista Lung Cancer Registry). Data from the first 3 years of the Paulista Lung Cancer Registry underwent an audit process with 3 metrics: completeness, consistency, and inter-rater reliability. The first 2 methods were applied to the whole data set, and the last method was calculated using 100 cases randomized for direct auditing. Inter-rater reliability was evaluated using percentage of agreement between the data collector and auditor and through calculation of Cohen's κ and intraclass correlation. The overall completeness per section ranged from 0.88 to 1.00, and the overall consistency was 0.96. Inter-rater reliability showed many variables with high disagreement (>10%). For numerical variables, intraclass correlation was a better metric than inter-rater reliability. Cohen's κ showed that most variables had moderate to substantial agreement. The methodological approach applied to the Paulista Lung Cancer Registry showed that completeness and consistency metrics did not sufficiently reflect the real quality status of a database. The inter-rater reliability associated with κ and intraclass correlation was a better quality metric than completeness and consistency metrics because it could determine the reliability of specific variables used in research or benchmark reports. This report can be a paradigm for future studies of data quality measurement. Copyright © 2018 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Model reliability and software quality assurance in simulation of nuclear fuel waste management systems

    International Nuclear Information System (INIS)

    Oeren, T.I.; Elzas, M.S.; Sheng, G.; Wageningen Agricultural Univ., Netherlands; McMaster Univ., Hamilton, Ontario)

    1985-01-01

    As is the case with all scientific simulation studies, computerized simulation of nuclear fuel waste management systems can introduce and hide various types of errors. Frameworks to clarify issues of model reliability and software quality assurance are offered. Potential problems with reference to the main areas of concern for reliability and quality are discussed; e.g., experimental issues, decomposition, scope, fidelity, verification, requirements, testing, correctness, robustness are treated with reference to the experience gained in the past. A list comprising over 80 most common computerization errors is provided. Software tools and techniques used to detect and to correct computerization errors are discussed

  2. The Quality of Life Scale (QOLS: Reliability, Validity, and Utilization

    Directory of Open Access Journals (Sweden)

    Anderson Kathryn L

    2003-10-01

    Full Text Available Abstract The Quality of Life Scale (QOLS, created originally by American psychologist John Flanagan in the 1970's, has been adapted for use in chronic illness groups. This paper reviews the development and psychometric testing of the QOLS. A descriptive review of the published literature was undertaken and findings summarized in the frequently asked questions format. Reliability, content and construct validity testing has been performed on the QOLS and a number of translations have been made. The QOLS has low to moderate correlations with physical health status and disease measures. However, content validity analysis indicates that the instrument measures domains that diverse patient groups with chronic illness define as quality of life. The QOLS is a valid instrument for measuring quality of life across patient groups and cultures and is conceptually distinct from health status or other causal indicators of quality of life.

  3. Improved reliability, accuracy and quality in automated NMR structure calculation with ARIA

    Energy Technology Data Exchange (ETDEWEB)

    Mareuil, Fabien [Institut Pasteur, Cellule d' Informatique pour la Biologie (France); Malliavin, Thérèse E.; Nilges, Michael; Bardiaux, Benjamin, E-mail: bardiaux@pasteur.fr [Institut Pasteur, Unité de Bioinformatique Structurale, CNRS UMR 3528 (France)

    2015-08-15

    In biological NMR, assignment of NOE cross-peaks and calculation of atomic conformations are critical steps in the determination of reliable high-resolution structures. ARIA is an automated approach that performs NOE assignment and structure calculation in a concomitant manner in an iterative procedure. The log-harmonic shape for distance restraint potential and the Bayesian weighting of distance restraints, recently introduced in ARIA, were shown to significantly improve the quality and the accuracy of determined structures. In this paper, we propose two modifications of the ARIA protocol: (1) the softening of the force field together with adapted hydrogen radii, which is meaningful in the context of the log-harmonic potential with Bayesian weighting, (2) a procedure that automatically adjusts the violation tolerance used in the selection of active restraints, based on the fitting of the structure to the input data sets. The new ARIA protocols were fine-tuned on a set of eight protein targets from the CASD–NMR initiative. As a result, the convergence problems previously observed for some targets was resolved and the obtained structures exhibited better quality. In addition, the new ARIA protocols were applied for the structure calculation of ten new CASD–NMR targets in a blind fashion, i.e. without knowing the actual solution. Even though optimisation of parameters and pre-filtering of unrefined NOE peak lists were necessary for half of the targets, ARIA consistently and reliably determined very precise and highly accurate structures for all cases. In the context of integrative structural biology, an increasing number of experimental methods are used that produce distance data for the determination of 3D structures of macromolecules, stressing the importance of methods that successfully make use of ambiguous and noisy distance data.

  4. Journey Toward High Reliability: A Comprehensive Safety Program to Improve Quality of Care and Safety Culture in a Large, Multisite Radiation Oncology Department.

    Science.gov (United States)

    Woodhouse, Kristina Demas; Volz, Edna; Maity, Amit; Gabriel, Peter E; Solberg, Timothy D; Bergendahl, Howard W; Hahn, Stephen M

    2016-05-01

    High-reliability organizations (HROs) focus on continuous identification and improvement of safety issues. We sought to advance a large, multisite radiation oncology department toward high reliability through the implementation of a comprehensive safety culture (SC) program at the University of Pennsylvania Department of Radiation Oncology. In 2011, with guidance from safety literature and experts in HROs, we designed an SC framework to reduce radiation errors. All state-reported medical events (SRMEs) from 2009 to 2016 were retrospectively reviewed and plotted on a control chart. Changes in SC grade were assessed using the Agency for Healthcare Research and Quality Hospital Survey. Outcomes measured included the number of radiation treatment fractions and days between SRMEs, as well as SC grade. Multifaceted safety initiatives were implemented at our main academic center and across all network sites. Postintervention results demonstrate increased staff fundamental safety knowledge, enhanced peer review with an electronic system, and special cause variation of SRMEs on control chart analysis. From 2009 to 2016, the number of days and fractions between SRMEs significantly increased, from a mean of 174 to 541 days (P safety framework. Our multifaceted initiatives, focusing on culture and system changes, can be successfully implemented in a large academic radiation oncology department to yield measurable improvements in SC and outcomes. Copyright © 2016 by American Society of Clinical Oncology.

  5. Studies on the reliability of high-field intra-operative MRI in brain glioma resection

    Directory of Open Access Journals (Sweden)

    Zhi-jun SONG

    2011-07-01

    Full Text Available Objective To evaluate the reliability of high-field intra-operative magnetic resonance imaging(iMRI in detecting the residual tumors during glioma resection.Method One hundred and thirty-one cases of brain glioma(69 males and 62 females,aged from 7 to 79 years with mean of 39.6 years hospitalized from Nov.2009 to Aug.2010 were involved in present study.All the patients were evaluated using magnetic resonance imaging(MRI before the operation.The tumors were resected under conventional navigation microscope,and the high-field iMRI was used for all the patients when the operators considered the tumor was satisfactorily resected,while the residual tumor was difficult to detect under the microscope,but resected after being revealed by high-field iMRI.Histopathological examination was performed.The patients without residual tumors recieved high-field MRI scan at day 4 or 5 after operation to evaluate the accuracy of high-field iMRI during operation.Results High quality intra-operative images were obtained by using high-field iMRI.Twenty-eight cases were excluded because their residual tumors were not resected due to their location too close to functional area.Combined with the results of intra-operative histopathological examination and post-operative MRI at the early recovery stage,the sensitivity of high-field iMRI in residual tumor diagnosis was 98.0%(49/50,the specificity was 94.3%(50/53,and the accuracy was 96.1%(99/103.Conclusion High-quality intra-operative imaging could be acquired by high-field iMRI,which maybe used as a safe and reliable method in detecting the residual tumors during glioma resection.

  6. Teaching Surgical Procedures with Movies: Tips for High-quality Video Clips

    OpenAIRE

    Jacquemart, Mathieu; Bouletreau, Pierre; Breton, Pierre; Mojallal, Ali; Sigaux, Nicolas

    2016-01-01

    Summary: Video must now be considered as a precious tool for learning surgery. However, the medium does present production challenges, and currently, quality movies are not always accessible. We developed a series of 7 surgical videos and made them available on a publicly accessible internet website. Our videos have been viewed by thousands of people worldwide. High-quality educational movies must respect strategic and technical points to be reliable.

  7. Teaching Surgical Procedures with Movies: Tips for High-quality Video Clips.

    Science.gov (United States)

    Jacquemart, Mathieu; Bouletreau, Pierre; Breton, Pierre; Mojallal, Ali; Sigaux, Nicolas

    2016-09-01

    Video must now be considered as a precious tool for learning surgery. However, the medium does present production challenges, and currently, quality movies are not always accessible. We developed a series of 7 surgical videos and made them available on a publicly accessible internet website. Our videos have been viewed by thousands of people worldwide. High-quality educational movies must respect strategic and technical points to be reliable.

  8. Quality and Reliability Aspects in Nuclear Power Reactor Fuel Engineering

    International Nuclear Information System (INIS)

    2015-01-01

    In order to decrease costs and increase competitiveness, nuclear utilities use more challenging operational conditions, longer fuel cycles and higher burnups, which require modifications in fuel designs and materials. Different aspects of quality assurance and control, as well as analysis of fuel performance have been considered in a number of specialized publications. The present publication provides a concise but comprehensive overview of all interconnected quality and reliability issues in fuel fabrication, design and operation. It jointly tackles technical, safety and organizational aspects, and contains examples of state of the art developments and good practices of coordinated work of fuel designers, vendors and reactor operators

  9. High-reliability computing for the smarter planet

    International Nuclear Information System (INIS)

    Quinn, Heather M.; Graham, Paul; Manuzzato, Andrea; Dehon, Andre

    2010-01-01

    The geometric rate of improvement of transistor size and integrated circuit performance, known as Moore's Law, has been an engine of growth for our economy, enabling new products and services, creating new value and wealth, increasing safety, and removing menial tasks from our daily lives. Affordable, highly integrated components have enabled both life-saving technologies and rich entertainment applications. Anti-lock brakes, insulin monitors, and GPS-enabled emergency response systems save lives. Cell phones, internet appliances, virtual worlds, realistic video games, and mp3 players enrich our lives and connect us together. Over the past 40 years of silicon scaling, the increasing capabilities of inexpensive computation have transformed our society through automation and ubiquitous communications. In this paper, we will present the concept of the smarter planet, how reliability failures affect current systems, and methods that can be used to increase the reliable adoption of new automation in the future. We will illustrate these issues using a number of different electronic devices in a couple of different scenarios. Recently IBM has been presenting the idea of a 'smarter planet.' In smarter planet documents, IBM discusses increased computer automation of roadways, banking, healthcare, and infrastructure, as automation could create more efficient systems. A necessary component of the smarter planet concept is to ensure that these new systems have very high reliability. Even extremely rare reliability problems can easily escalate to problematic scenarios when implemented at very large scales. For life-critical systems, such as automobiles, infrastructure, medical implantables, and avionic systems, unmitigated failures could be dangerous. As more automation moves into these types of critical systems, reliability failures will need to be managed. As computer automation continues to increase in our society, the need for greater radiation reliability is necessary

  10. High-reliability computing for the smarter planet

    Energy Technology Data Exchange (ETDEWEB)

    Quinn, Heather M [Los Alamos National Laboratory; Graham, Paul [Los Alamos National Laboratory; Manuzzato, Andrea [UNIV OF PADOVA; Dehon, Andre [UNIV OF PENN; Carter, Nicholas [INTEL CORPORATION

    2010-01-01

    The geometric rate of improvement of transistor size and integrated circuit performance, known as Moore's Law, has been an engine of growth for our economy, enabling new products and services, creating new value and wealth, increasing safety, and removing menial tasks from our daily lives. Affordable, highly integrated components have enabled both life-saving technologies and rich entertainment applications. Anti-lock brakes, insulin monitors, and GPS-enabled emergency response systems save lives. Cell phones, internet appliances, virtual worlds, realistic video games, and mp3 players enrich our lives and connect us together. Over the past 40 years of silicon scaling, the increasing capabilities of inexpensive computation have transformed our society through automation and ubiquitous communications. In this paper, we will present the concept of the smarter planet, how reliability failures affect current systems, and methods that can be used to increase the reliable adoption of new automation in the future. We will illustrate these issues using a number of different electronic devices in a couple of different scenarios. Recently IBM has been presenting the idea of a 'smarter planet.' In smarter planet documents, IBM discusses increased computer automation of roadways, banking, healthcare, and infrastructure, as automation could create more efficient systems. A necessary component of the smarter planet concept is to ensure that these new systems have very high reliability. Even extremely rare reliability problems can easily escalate to problematic scenarios when implemented at very large scales. For life-critical systems, such as automobiles, infrastructure, medical implantables, and avionic systems, unmitigated failures could be dangerous. As more automation moves into these types of critical systems, reliability failures will need to be managed. As computer automation continues to increase in our society, the need for greater radiation reliability is

  11. Validity and reliability of the Portuguese version of the quality of life in epilepsy inventory (QOLIE-31) for Brazil.

    Science.gov (United States)

    da Silva, Tatiana Indelicato; Ciconelli, Rozana Mesquita; Alonso, Neide Barreira; Azevedo, Auro Mauro; Westphal-Guitti, Ana Carolina; Pascalicchio, Tatiana Frascarelli; Marques, Carolina Mattos; Caboclo, Luís Otávio Sales Ferreira; Cramer, Joyce A; Sakamoto, Américo Ceiki; Yacubian, Elza Márcia Targas

    2007-03-01

    We report the cultural adaptation and psychometric properties of the Quality of Life in Epilepsy-31 Inventory (QOLIE-31) for the Portuguese language and Brazilian culture. This study involved 150 outpatients: 50 presurgical patients with refractory temporal lobe epilepsy (TLE) related to mesial temporal sclerosis (MTS), 50 patients with juvenile myoclonic epilepsy (JME), and 50 seizure-free patients with TLE. They completed the QOLIE-31, Nottingham Health Profile (NHP), Beck Depression Inventory (BDI), and Adverse Events Profile (AEP) and underwent a neuropsychological evaluation (NE). Internal consistency reliability, interrater and test-retest reliability, and construct validity were assessed. QOLIE-31 mean scores were 33.1 (Social Function), 68.9 (Overall Quality of Life), 56.5 (Seizure Worry), 64.1 (Emotional Well-Being), 63.7 (Energy/Fatigue), 38.9 (Cognitive Function), and 49.7 (Medication Effects). Internal consistency was high (Cronbach's alpha), as were the associations between QOLIE-31 and the BDI, NHP, AEP, and NE. The Portuguese/Brazilian version of the QOLIE-31 inventory showed good reliability, validity, and construct validity.

  12. Based on Weibull Information Fusion Analysis Semiconductors Quality the Key Technology of Manufacturing Execution Systems Reliability

    Science.gov (United States)

    Huang, Zhi-Hui; Tang, Ying-Chun; Dai, Kai

    2016-05-01

    Semiconductor materials and Product qualified rate are directly related to the manufacturing costs and survival of the enterprise. Application a dynamic reliability growth analysis method studies manufacturing execution system reliability growth to improve product quality. Refer to classical Duane model assumptions and tracking growth forecasts the TGP programming model, through the failure data, established the Weibull distribution model. Combining with the median rank of average rank method, through linear regression and least squares estimation method, match respectively weibull information fusion reliability growth curve. This assumption model overcome Duane model a weakness which is MTBF point estimation accuracy is not high, through the analysis of the failure data show that the method is an instance of the test and evaluation modeling process are basically identical. Median rank in the statistics is used to determine the method of random variable distribution function, which is a good way to solve the problem of complex systems such as the limited sample size. Therefore this method has great engineering application value.

  13. Quality Evaluation Scores are no more Reliable than Gestalt in Evaluating the Quality of Emergency Medicine Blogs: A METRIQ Study.

    Science.gov (United States)

    Thoma, Brent; Sebok-Syer, Stefanie S; Colmers-Gray, Isabelle; Sherbino, Jonathan; Ankel, Felix; Trueger, N Seth; Grock, Andrew; Siemens, Marshall; Paddock, Michael; Purdy, Eve; Kenneth Milne, William; Chan, Teresa M

    2018-01-30

    Construct: We investigated the quality of emergency medicine (EM) blogs as educational resources. Online medical education resources such as blogs are increasingly used by EM trainees and clinicians. However, quality evaluations of these resources using gestalt are unreliable. We investigated the reliability of two previously derived quality evaluation instruments for blogs. Sixty English-language EM websites that published clinically oriented blog posts between January 1 and February 24, 2016, were identified. A random number generator selected 10 websites, and the 2 most recent clinically oriented blog posts from each site were evaluated using gestalt, the Academic Life in Emergency Medicine (ALiEM) Approved Instructional Resources (AIR) score, and the Medical Education Translational Resources: Impact and Quality (METRIQ-8) score, by a sample of medical students, EM residents, and EM attendings. Each rater evaluated all 20 blog posts with gestalt and 15 of the 20 blog posts with the ALiEM AIR and METRIQ-8 scores. Pearson's correlations were calculated between the average scores for each metric. Single-measure intraclass correlation coefficients (ICCs) evaluated the reliability of each instrument. Our study included 121 medical students, 88 EM residents, and 100 EM attendings who completed ratings. The average gestalt rating of each blog post correlated strongly with the average scores for ALiEM AIR (r = .94) and METRIQ-8 (r = .91). Single-measure ICCs were fair for gestalt (0.37, IQR 0.25-0.56), ALiEM AIR (0.41, IQR 0.29-0.60) and METRIQ-8 (0.40, IQR 0.28-0.59). The average scores of each blog post correlated strongly with gestalt ratings. However, neither ALiEM AIR nor METRIQ-8 showed higher reliability than gestalt. Improved reliability may be possible through rater training and instrument refinement.

  14. Next Generation High Quality Videoconferencing Service for the LHC

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    In recent times, we have witnessed an explosion of video initiatives in the industry worldwide. Several advancements in video technology are currently improving the way we interact and collaborate. These advancements are forcing tendencies and overall experiences: any device in any network can be used to collaborate, in most cases with an overall high quality. To cope with this technology progresses, CERN IT Department has taken the leading role to establish strategies and directions to improve the user experience in remote dispersed meetings and remote collaboration at large in the worldwide LHC communities. Due to the high rate of dispersion in the LHC user communities, these are critically dependent of videoconferencing technology, with a need of robustness and high quality for the best possible user experience. We will present an analysis of the factors that influenced the technical and strategic choices to improve the reliability, efficiency and overall quality of the LHC remote sessions. In particular, ...

  15. About water chemistry influence on equipment reliability of NPP with RBMK-1000

    International Nuclear Information System (INIS)

    Berezina, I.G.; Styazhkin, P.S.; Kritskij, V.G.

    2001-01-01

    In the paper the experience of a quantitative valuation of coolant quality influence on a reliability of some equipment elements of NPP with RBMK-1000 is offered. The choice is made of coolant quality integral parameter. The connection between indices values of coolant quality and reliability of major elements of circulation circuit equipment (including fuel claddings) is established. The reliability improvement of equipment elements operation is supported by high water chemistry quality. (orig.)

  16. Column Grid Array Rework for High Reliability

    Science.gov (United States)

    Mehta, Atul C.; Bodie, Charles C.

    2008-01-01

    Due to requirements for reduced size and weight, use of grid array packages in space applications has become common place. To meet the requirement of high reliability and high number of I/Os, ceramic column grid array packages (CCGA) were selected for major electronic components used in next MARS Rover mission (specifically high density Field Programmable Gate Arrays). ABSTRACT The probability of removal and replacement of these devices on the actual flight printed wiring board assemblies is deemed to be very high because of last minute discoveries in final test which will dictate changes in the firmware. The questions and challenges presented to the manufacturing organizations engaged in the production of high reliability electronic assemblies are, Is the reliability of the PWBA adversely affected by rework (removal and replacement) of the CGA package? and How many times can we rework the same board without destroying a pad or degrading the lifetime of the assembly? To answer these questions, the most complex printed wiring board assembly used by the project was chosen to be used as the test vehicle, the PWB was modified to provide a daisy chain pattern, and a number of bare PWB s were acquired to this modified design. Non-functional 624 pin CGA packages with internal daisy chained matching the pattern on the PWB were procured. The combination of the modified PWB and the daisy chained packages enables continuity measurements of every soldered contact during subsequent testing and thermal cycling. Several test vehicles boards were assembled, reworked and then thermal cycled to assess the reliability of the solder joints and board material including pads and traces near the CGA. The details of rework process and results of thermal cycling are presented in this paper.

  17. Examination of Operation Quality for High-frequent Railway Operation

    DEFF Research Database (Denmark)

    Landex, Alex; Kaas, Anders H.

    2009-01-01

    take the first train in their direction. The article examines four different approaches to examine operation quality for high-frequent operation that are based on the experiences of the passengers. These approaches are the service frequency of the operation, travel time extension, a combination......The examination of operation quality for high-frequent operation requires other approaches than the typical evaluation of punctuality (trains on time) and reliability (operated trains). This is because passengers in high-frequent railway systems do not necessarily notice train delays as they just...... of the service frequency and travel time approaches, and passenger delays. The service frequency and travel time approaches are simple measurements with low complexity and complement each other. Therefore, the article recommends combining the service frequency and travel time approaches to get a more accurate...

  18. Methods for slow axis beam quality improvement of high power broad area diode lasers

    Science.gov (United States)

    An, Haiyan; Xiong, Yihan; Jiang, Ching-Long J.; Schmidt, Berthold; Treusch, Georg

    2014-03-01

    For high brightness direct diode laser systems, it is of fundamental importance to improve the slow axis beam quality of the incorporated laser diodes regardless what beam combining technology is applied. To further advance our products in terms of increased brightness at a high power level, we must optimize the slow axis beam quality despite the far field blooming at high current levels. The later is caused predominantly by the built-in index step in combination with the thermal lens effect. Most of the methods for beam quality improvements reported in publications sacrifice the device efficiency and reliable output power. In order to improve the beam quality as well as maintain the efficiency and reliable output power, we investigated methods of influencing local heat generation to reduce the thermal gradient across the slow axis direction, optimizing the built-in index step and discriminating high order modes. Based on our findings, we have combined different methods in our new device design. Subsequently, the beam parameter product (BPP) of a 10% fill factor bar has improved by approximately 30% at 7 W/emitter without efficiency penalty. This technology has enabled fiber coupled high brightness multi-kilowatt direct diode laser systems. In this paper, we will elaborate on the methods used as well as the results achieved.

  19. Improving the quality of discrete-choice experiments in health: how can we assess validity and reliability?

    Science.gov (United States)

    Janssen, Ellen M; Marshall, Deborah A; Hauber, A Brett; Bridges, John F P

    2017-12-01

    The recent endorsement of discrete-choice experiments (DCEs) and other stated-preference methods by regulatory and health technology assessment (HTA) agencies has placed a greater focus on demonstrating the validity and reliability of preference results. Areas covered: We present a practical overview of tests of validity and reliability that have been applied in the health DCE literature and explore other study qualities of DCEs. From the published literature, we identify a variety of methods to assess the validity and reliability of DCEs. We conceptualize these methods to create a conceptual model with four domains: measurement validity, measurement reliability, choice validity, and choice reliability. Each domain consists of three categories that can be assessed using one to four procedures (for a total of 24 tests). We present how these tests have been applied in the literature and direct readers to applications of these tests in the health DCE literature. Based on a stakeholder engagement exercise, we consider the importance of study characteristics beyond traditional concepts of validity and reliability. Expert commentary: We discuss study design considerations to assess the validity and reliability of a DCE, consider limitations to the current application of tests, and discuss future work to consider the quality of DCEs in healthcare.

  20. Delivering high performance BWR fuel reliably

    International Nuclear Information System (INIS)

    Schardt, J.F.

    1998-01-01

    Utilities are under intense pressure to reduce their production costs in order to compete in the increasingly deregulated marketplace. They need fuel, which can deliver high performance to meet demanding operating strategies. GE's latest BWR fuel design, GE14, provides that high performance capability. GE's product introduction process assures that this performance will be delivered reliably, with little risk to the utility. (author)

  1. Highly reliable electro-hydraulic control system

    International Nuclear Information System (INIS)

    Mande, Morima; Hiyama, Hiroshi; Takahashi, Makoto

    1984-01-01

    The unscheduled shutdown of nuclear power stations disturbs power system, and exerts large influence on power generation cost due to the lowering of capacity ratio; therefore, high reliability is required for the control system of nuclear power stations. Toshiba Corp. has exerted effort to improve the reliability of the control system of power stations, and in this report, the electro-hydraulic control system for the turbines of nuclear power stations is described. The main functions of the electro-hydraulic control system are the control of main steam pressure with steam regulation valves and turbine bypass valves, the control of turbine speed and load, the prevention of turbine overspeed, the protection of turbines and so on. The system is composed of pressure sensors and a speed sensor, the control board containing the electronic circuits for control computation and protective sequence, the oil cylinders, servo valves and opening detectors of the valves for control, a high pressure oil hydraulic machine and piping, the operating panel and so on. The main features are the adoption of tripling intermediate value selection method, the multiplying of protection sensors and the adoption of 2 out of 3 trip logic, the multiplying of power sources, the improvement of the reliability of electronic circuit hardware and oil hydraulic system. (Kako, I.)

  2. TURKISH VERSION QUALITY OF LIFE IN ESSENTIAL TREMOR QUESTIONNAIRE (QUEST): VALIDITY AND RELIABILITY STUDY.

    Science.gov (United States)

    Güler, Sibel; Turan, F Nesrin

    2015-09-30

    Our aim was to translate the Quality of Life in Essential Tremor Questionnaire (QUEST) advanced by Troster (2005) and to analyse the validity and reliability of this questionnaire. Two hundred twelve consecutive patients with essential tremor (ET) and forty-three control subjects were included in the study. Permission for the translation and validation of the QUEST scale was obtained. The translation was performed according to the guidelines provided by the publisher. After the translation, the final version of the scale was administered to both groups to determine its reliability and validity. The QUEST Physical, Psychosocial, communication, Hobbies/leisure and Work/finance scores were 0.967, 0.968, 0.933, 0.964 and 0.925, respectively. There were good correlations between each of the QUEST scores that were indicative of good internal consistency. Additionally, we observed that all of the QUEST scores were most strongly related to the right and left arms (p=0.0001). However, we observed that all of the QUEST scores were weakly related to the voice, head and right leg (p=0.0001). These findings support the notion that the Turkish version of the Quality of Life in Essential Tremor (QUEST) questionnaire is a valid and reliable tool for the assessment of the quality of life of patients with ET.

  3. Development of High Quality 4H-SiC Thick Epitaxy for Reliable High Power Electronics Using Halogenated Precursors

    Science.gov (United States)

    2016-08-02

    defects :=()llowed by a second buffer epilayer gro\\\\ th with ~: urn thickness with high n-type dopi:1g (- 5£17 cm-3) for the same C/Si ratio of ~1.4 at...gradient, pressure , etc.) can further reduce the parasitic deposition, especially in TFS-growth. • Thick epitaxy on-axis 4H-SiC Growth at High Growth...From - To) 08/02/2016 Final Technical Report 01-Apr-10 Through 31-Mar-14 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Development of High Quality 4H

  4. Delivering high performance BWR fuel reliably

    Energy Technology Data Exchange (ETDEWEB)

    Schardt, J.F. [GE Nuclear Energy, Wilmington, NC (United States)

    1998-07-01

    Utilities are under intense pressure to reduce their production costs in order to compete in the increasingly deregulated marketplace. They need fuel, which can deliver high performance to meet demanding operating strategies. GE's latest BWR fuel design, GE14, provides that high performance capability. GE's product introduction process assures that this performance will be delivered reliably, with little risk to the utility. (author)

  5. Parametric and semiparametric models with applications to reliability, survival analysis, and quality of life

    CERN Document Server

    Nikulin, M; Mesbah, M; Limnios, N

    2004-01-01

    Parametric and semiparametric models are tools with a wide range of applications to reliability, survival analysis, and quality of life. This self-contained volume examines these tools in survey articles written by experts currently working on the development and evaluation of models and methods. While a number of chapters deal with general theory, several explore more specific connections and recent results in "real-world" reliability theory, survival analysis, and related fields.

  6. Coal quality influence on availability and reliability of two 620 MW lignite fired units after 100 000 operating hours

    International Nuclear Information System (INIS)

    Markovic, Dragomir

    1997-01-01

    General statistics data on operation of two 620 MW low calorific value coal fired units are foundation for analysis of influence of variable coal characteristics on availability and reliability. Changeable mineralogical structure, ash contents and heating value cause the following problems: increased abrasive wear and unstable firing. Almost 23 % of plant shutting down are caused by the mentioned reasons, which have multiplied in the last years. Analysis will show how it is possible to plan terms of overhaul of boilers with respect to quality of used coal and reliability of pipe system and maintenance of high level of availability and reliability in spite of periodical low heating value of coal. Described experiences are also important for planning, design, construction and operation of new power plants firing with same coal. (Author)

  7. Custom high-reliability radiation-hard CMOS-LSI circuit design

    International Nuclear Information System (INIS)

    Barnard, W.J.

    1981-01-01

    Sandia has developed a custom CMOS-LSI design capability to provide high reliability radiation-hardened circuits. This capability relies on (1) proven design practices to enhance reliability, (2) use of well characterized cells and logic modules, (3) computer-aided design tools to reduce design time and errors and to standardize design definition, and (4) close working relationships with the system designer and technology fabrication personnel. Trade-offs are made during the design between circuit complexity/performance and technology/producibility for high reliability and radiation-hardened designs to result. Sandia has developed and is maintaining a radiation-hardened bulk CMOS technology fabrication line for production of prototype and small production volume parts

  8. High Reliability Oscillators for Terahertz Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — To develop reliable THz sources with high power and high DC-RF efficiency, Virginia Diodes, Inc. will develop a thorough understanding of the complex interactions...

  9. Acceptability, reliability, and validity of the Stroke and Aphasia Quality of Life Scale-39 (SAQOL-39) across languages: a systematic review.

    Science.gov (United States)

    Ahmadi, Akram; Tohidast, Seyed Abolfazl; Mansuri, Banafshe; Kamali, Mohammad; Krishnan, Gopee

    2017-09-01

    This systematic review aimed to explore the acceptability, reliability, and validity of the Stroke and Aphasia Quality of Life-39 (SAQOL-39) scale across languages. We employed a systematic search of the online databases including MEDLINE (Pubmed), Science direct, Web of science, Psychinfo, Scopus, ProQuest, Google Scholar, and Cochrane library published between 2003 and 2016. We used PRISMA guidelines for conducting and reporting this review. Subsequently, screening of the titles and abstracts, extraction of data as well as the appraisal of the quality of relevant studies were carried out. The initial search returned 8185 studies. Subsequent screening and study selection processes narrowed them to 20, needing detailed review. Forward-backward translation scheme was the preferred method for translation of the SAQOL-39 from English to other languages. Mainly, the socio-cultural and linguistic adaptations were performed in the translated versions. Most versions of the SAQOL-39 showed high test-retest reliability and internal consistency. However, several psychometric properties including the validity and responsiveness were seldom reported in these versions. The SAQOL-39 scale showed high acceptability, and reliability across the languages reviewed in this study. Future translations may additionally focus on reporting the validity and responsiveness of the instrument.

  10. Assessment of microelectronics packaging for high temperature, high reliability applications

    Energy Technology Data Exchange (ETDEWEB)

    Uribe, F.

    1997-04-01

    This report details characterization and development activities in electronic packaging for high temperature applications. This project was conducted through a Department of Energy sponsored Cooperative Research and Development Agreement between Sandia National Laboratories and General Motors. Even though the target application of this collaborative effort is an automotive electronic throttle control system which would be located in the engine compartment, results of this work are directly applicable to Sandia`s national security mission. The component count associated with the throttle control dictates the use of high density packaging not offered by conventional surface mount. An enabling packaging technology was selected and thermal models defined which characterized the thermal and mechanical response of the throttle control module. These models were used to optimize thick film multichip module design, characterize the thermal signatures of the electronic components inside the module, and to determine the temperature field and resulting thermal stresses under conditions that may be encountered during the operational life of the throttle control module. Because the need to use unpackaged devices limits the level of testing that can be performed either at the wafer level or as individual dice, an approach to assure a high level of reliability of the unpackaged components was formulated. Component assembly and interconnect technologies were also evaluated and characterized for high temperature applications. Electrical, mechanical and chemical characterizations of enabling die and component attach technologies were performed. Additionally, studies were conducted to assess the performance and reliability of gold and aluminum wire bonding to thick film conductor inks. Kinetic models were developed and validated to estimate wire bond reliability.

  11. Analysis of fatigue reliability for high temperature and high pressure multi-stage decompression control valve

    Science.gov (United States)

    Yu, Long; Xu, Juanjuan; Zhang, Lifang; Xu, Xiaogang

    2018-03-01

    Based on stress-strength interference theory to establish the reliability mathematical model for high temperature and high pressure multi-stage decompression control valve (HMDCV), and introduced to the temperature correction coefficient for revising material fatigue limit at high temperature. Reliability of key dangerous components and fatigue sensitivity curve of each component are calculated and analyzed by the means, which are analyzed the fatigue life of control valve and combined with reliability theory of control valve model. The impact proportion of each component on the control valve system fatigue failure was obtained. The results is shown that temperature correction factor makes the theoretical calculations of reliability more accurate, prediction life expectancy of main pressure parts accords with the technical requirements, and valve body and the sleeve have obvious influence on control system reliability, the stress concentration in key part of control valve can be reduced in the design process by improving structure.

  12. Validity and reliability of the patient assessment of constipation quality of life questionnaire for the Turkish population.

    Science.gov (United States)

    Bengi, Göksel; Yalçın, Mustafa; Akpınar, Hale; Keskinoğlu, Pembe; Ellidokuz, Hülya

    2015-07-01

    There are few specific evaluation forms for evaluating the quality of life among patients with chronic constipation. Our study aimed to determine the validity and reliability of the translated Patient Assessment of Constipation Quality of Life (PAC-QOL) questionnaire for the Turkish population because evidence of its reliability and validity is required to justify its use in other studies and clinical practice. This study included 154 patients with constipation who were treated at the Department of Gastroenterology, Dokuz Eylül University Hospital between January and June 2012. The translated PAC-QOL questionnaire was completed by patients at the clinic and also at a 2-week follow-up to test its reliability. Cronbach's alpha coefficient (internal consistency) was 0.91 (good) for the translated PAC-QOL questionnaire. Time validity was evaluated using the intraclass correlation coefficient (ICC) method, and the ICC value for all questions was confirmed as 0.68 at the 2-week follow-up. The validity of the tool in the study group was evaluated using factor analysis, and the results were highly significant (Kaiser-Meyer-Olkin value: 0.857; Bartlett's test: p=0.001). Questions were categorized according to six factors based on the factor analysis, and these factors explained 65.1% of the total variation. For hypothesis verification of the tool, the correlation coefficient for PAC-QOL and PAC Symptoms (PAC-SYM) was r=0.577 (p<0.001), whereas the correlation coefficient for PAC-QOL and constipation severity score was r=0.457 (p<0.001). The PAC-QOL questionnaire was reliable, although not valid because of the limited sample group.

  13. A Chinese version of the City of Hope Quality of Life-Ostomy Questionnaire: validity and reliability assessment.

    Science.gov (United States)

    Gao, Wenjun; Yuan, Changrong; Wang, Jichuan; Du, Jiarui; Wu, Huiqiao; Qian, Xiaojie; Hinds, Pamela S

    2013-01-01

    The City of Hope Quality of Life-Ostomy Questionnaire is a widely accepted scale to assess quality of life in ostomy patients. However, the validity and reliability of the Chinese version (C-COH) have not been studied. The objective of the study was to assess the validity and reliability of the C-COH among ostomy patients sampled from Shanghai from August 2010 to June 2011. Content validity was examined based on the reviews of a panel of 10 experts; test-retest was conducted to assess the item reliabilities of the scale; a pilot sample (n = 274) was selected to explore the factorial structure of the C-COH using exploratory factor analysis; a validation sample (n = 370) was selected to confirm the findings from the exploratory study using confirmatory factor analysis (CFA). Statistical package SPSS version 16.0 was used for the exploratory factor analysis, and Amos 17.0 was used for the CFA. The C-COH was developed by modifying 1 item and excluding 11 items from the original scale. Four factors/subscales (physical well-being, psychological well-being, social well-being, and spiritual well-being) were identified and confirmed in the C-COH The scale reliabilities estimated from the CFA results for the 4 subscales were 0.860, 0.885, 0.864, and 0.686, respectively. Findings support the reliability and validity of the C-COH. The C-COH could be a useful measure of the level of quality of life among Chinese patients with a stoma and may provide important intervention implications for healthcare providers to help improve the life quality of patients with a stoma.

  14. Evaluation of conventional electric power generating industry quality assurance and reliability practices

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, R.T.; Lauffenburger, H.A.

    1981-03-01

    The techniques and practices utilized in an allied industry (electric power generation) that might serve as a baseline for formulating Quality Assurance and Reliability (QA and R) procedures for photovoltaic solar energy systems were studied. The study results provide direct near-term input for establishing validation methods as part of the SERI performance criteria and test standards development task.

  15. High reliability low jitter 80 kV pulse generator

    International Nuclear Information System (INIS)

    Savage, Mark Edward; Stoltzfus, Brian Scott

    2009-01-01

    Switching can be considered to be the essence of pulsed power. Time accurate switch/trigger systems with low inductance are useful in many applications. This article describes a unique switch geometry coupled with a low-inductance capacitive energy store. The system provides a fast-rising high voltage pulse into a low impedance load. It can be challenging to generate high voltage (more than 50 kilovolts) into impedances less than 10 (Omega), from a low voltage control signal with a fast rise time and high temporal accuracy. The required power amplification is large, and is usually accomplished with multiple stages. The multiple stages can adversely affect the temporal accuracy and the reliability of the system. In the present application, a highly reliable and low jitter trigger generator was required for the Z pulsed-power facility [M. E. Savage, L. F. Bennett, D. E. Bliss, W. T. Clark, R. S. Coats,J. M. Elizondo, K. R. LeChien, H. C. Harjes, J. M. Lehr, J. E. Maenchen, D. H. McDaniel, M. F. Pasik, T. D. Pointon, A. C. Owen, D. B. Seidel, D. L. Smith, B. S. Stoltzfus, K.W. Struve, W.A. Stygar, L.K. Warne, and J. R. Woodworth, 2007 IEEE Pulsed Power Conference, Albuquerque, NM (IEEE, Piscataway, NJ, 2007), p. 979]. The large investment in each Z experiment demands low prefire probability and low jitter simultaneously. The system described here is based on a 100 kV DC-charged high-pressure spark gap, triggered with an ultraviolet laser. The system uses a single optical path for simultaneously triggering two parallel switches, allowing lower inductance and electrode erosion with a simple optical system. Performance of the system includes 6 ns output rise time into 5.6 (Omega), 550 ps one-sigma jitter measured from the 5 V trigger to the high voltage output, and misfire probability less than 10 -4 . The design of the system and some key measurements will be shown in the paper. We will discuss the design goals related to high reliability and low jitter. While

  16. Reliable Exfoliation of Large-Area High-Quality Flakes of Graphene and Other Two-Dimensional Materials.

    Science.gov (United States)

    Huang, Yuan; Sutter, Eli; Shi, Norman N; Zheng, Jiabao; Yang, Tianzhong; Englund, Dirk; Gao, Hong-Jun; Sutter, Peter

    2015-11-24

    Mechanical exfoliation has been a key enabler of the exploration of the properties of two-dimensional materials, such as graphene, by providing routine access to high-quality material. The original exfoliation method, which remained largely unchanged during the past decade, provides relatively small flakes with moderate yield. Here, we report a modified approach for exfoliating thin monolayer and few-layer flakes from layered crystals. Our method introduces two process steps that enhance and homogenize the adhesion force between the outermost sheet in contact with a substrate: Prior to exfoliation, ambient adsorbates are effectively removed from the substrate by oxygen plasma cleaning, and an additional heat treatment maximizes the uniform contact area at the interface between the source crystal and the substrate. For graphene exfoliation, these simple process steps increased the yield and the area of the transferred flakes by more than 50 times compared to the established exfoliation methods. Raman and AFM characterization shows that the graphene flakes are of similar high quality as those obtained in previous reports. Graphene field-effect devices were fabricated and measured with back-gating and solution top-gating, yielding mobilities of ∼4000 and 12,000 cm(2)/(V s), respectively, and thus demonstrating excellent electrical properties. Experiments with other layered crystals, e.g., a bismuth strontium calcium copper oxide (BSCCO) superconductor, show enhancements in exfoliation yield and flake area similar to those for graphene, suggesting that our modified exfoliation method provides an effective way for producing large area, high-quality flakes of a wide range of 2D materials.

  17. A new kind high-reliability digital reactivity meter

    International Nuclear Information System (INIS)

    Shen Feng; Jiang Zongbing

    2001-01-01

    The paper introduces a new kind of high-reliability Digital Reactivity Meter developed by the DRM developing group in designing department of Nuclear Power Institute of China. The meter has two independent measure channels, which can be set as either master-slave structure or working independently. This structure will ensure that the meter can continually fulfill its online measure task under the condition of single failure with it. It provides a solution for the conflict between nuclear station's extreme demand in DRM's reliability and instability of computer's business software platform. The instrument reaches both advance and reliability by covering a lot of kinds of complex functions in data process and display

  18. [The external evaluation of study quality: the role in maintaining the reliability of laboratory information].

    Science.gov (United States)

    Men'shikov, V V

    2013-08-01

    The external evaluation of quality of clinical laboratory examinations was gradually introduced in USSR medical laboratories since 1970s. In Russia, in the middle of 1990 a unified all-national system of external evaluation quality was organized known as the Federal center of external evaluation of quality at the basis of laboratory of the state research center of preventive medicine. The main positions of policy in this area were neatly formulated in the guidance documents of ministry of Health. Nowadays, the center of external evaluation of quality proposes 100 and more types of control studies and permanently extends their specter starting from interests of different disciplines of clinical medicine. The consistent participation of laboratories in the cycles of external evaluation of quality intrinsically promotes improvement of indicators of properness and precision of analysis results and increases reliability of laboratory information. However, a significant percentage of laboratories does not participate at all in external evaluation of quality or takes part in control process irregularly and in limited number of tests. The managers of a number of medical organizations disregard the application of the proposed possibilities to increase reliability of laboratory information and limit financing of studies in the field of quality control. The article proposes to adopt the national standard on the basis of ISO 17043 "Evaluation of compliance. The common requirements of professional competence testing".

  19. System Reliability Engineering

    International Nuclear Information System (INIS)

    Lim, Tae Jin

    2005-02-01

    This book tells of reliability engineering, which includes quality and reliability, reliability data, importance of reliability engineering, reliability and measure, the poisson process like goodness of fit test and the poisson arrival model, reliability estimation like exponential distribution, reliability of systems, availability, preventive maintenance such as replacement policies, minimal repair policy, shock models, spares, group maintenance and periodic inspection, analysis of common cause failure, and analysis model of repair effect.

  20. Validity, reliability and responsiveness of the Body Image Quality of Life Inventory in patients treated for infective endocarditis

    DEFF Research Database (Denmark)

    Rasmussen, Trine Bernholdt; Konradsen, Hanne; Dixon, Jane

    2017-01-01

    been validated in this patient population. The purpose of this study was thus to assess the validity, reliability and responsiveness of the Danish Body Image Quality of Life Inventory (BIQLI-DA) on patients treated for IE. METHODS: We evaluated the psychometric properties of the BIQLI-DA on data......: The BIQLI-DA may be applicable in healthcare research as it seems to be valid, reliable and responsive; however, evidence should be strengthened through further exploration of instrument performance, particularly regarding responsiveness.......: Participants were seventy patients with a mean age of 58 years and of which 83% were men. Results indicated convergent construct validity by confirming hypothesised associations to potentially related constructs. The BIQLI-DA was found to be highly internally consistent with a Cronbach's alpha of 0...

  1. How Reliable Are Students' Evaluations of Teaching Quality? A Variance Components Approach

    Science.gov (United States)

    Feistauer, Daniela; Richter, Tobias

    2017-01-01

    The inter-rater reliability of university students' evaluations of teaching quality was examined with cross-classified multilevel models. Students (N = 480) evaluated lectures and seminars over three years with a standardised evaluation questionnaire, yielding 4224 data points. The total variance of these student evaluations was separated into the…

  2. Validity, reliability and understanding of the EORTC-C30 and EORTC-BR23, quality of life questionnaires specific for breast cancer

    Directory of Open Access Journals (Sweden)

    Fernanda Alessandra Silva Michels

    2013-06-01

    Full Text Available Objective: To validate and assess reliability and understanding of the EORTC–C30 quality of life questionnaire and its breast cancer specific module, the EORTC-BR23. Methods: This study was conducted at the AC Camargo Cancer Hospital, São Paulo, Brazil. A total of 100 women diagnosed with breast cancer were interviewed. Internal consistency, confirmatory factorial analysis, convergent validity, construct validity and degree of understanding were examined. Reliability was assessed by comparison of means at times 1 and 2, inter-class coefficient and Bland-Altman graphics. Results: Cronbach’s alpha ranged from 0.72 to 0.86 for the EORTC-C30 and from 0.78 to 0.83 for the EORTC-BR23 questionnaire. Most questions were confirmed in the confirmatory factorial analysis. In the construct validity analysis, the questionnaires were capable of differentiating patients with or without lymphedema, apart from the symptom scales of both questionnaires. Both questionnaires presented a significant correlation in most domains of the SF-36, in the convergent validity analysis. Only a few criticisms were reported concerning questions, and the mean grade of understanding was high (C30 = 4.91 and BR23 = 4.89. The questionnaires presented good rates of reliability, with the exception of the functional scale of the C30 and the symptom scale of the BR23. Conclusions: The EORTC-C30 and EORTC-BR23 quality of life questionnaires were validated, presented good rates of reliability and are easily understood, allowing them to be used in Brazil to assess quality of life among women with breast cancer.

  3. Percutaneous vertebroplasty with a high-quality rotational angiographic unit

    Energy Technology Data Exchange (ETDEWEB)

    Pedicelli, Alessandro [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: apedicelli@rm.unicatt.it; Rollo, Massimo [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: mrollo@rm.unicatt.it; Piano, Mariangela [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: mariangela.piano@gmail.com; Re, Thomas J. [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: tomjre@gmail.com; Cipriani, Maria C. [Department of Gerontology, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: alexped@yahoo.com; Colosimo, Cesare [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: colosimo@rm.unicatt.it; Bonomo, Lorenzo [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: lbonomo@rm.unicatt.it

    2009-02-15

    We evaluated the reliability of a rotational angiographic unit (RA) with flat-panel detector as a single technique to guide percutaneous vertebroplasty (PVP) and for post-procedure assessment by 2D and 3D reformatted images. Fifty-five consecutive patients (104 vertebral bodies) were treated under RA fluoroscopy. Rotational acquisitions with 2D and 3D reconstruction were obtained in all patients for immediate post-procedure assessment. In complex cases, this technique was also used to evaluate the needle position during the procedure. All patients underwent CT scan after the procedure. RA and CT findings were compared. In all cases, a safe trans-pedicular access and an accurate control of the bone-cement injection were successfully performed with high-quality fluoroscopy, even at the thoracic levels and in case of vertebra plana. 2D and 3D rotational reconstructions permitted CT-like images that clearly showed needle position and were similar to CT findings in depicting intrasomatic implant-distribution. RA detected 40 cement leakages compared to 42 demonstrated by CT and showed overall 95% sensitivity and 100% specificity compared to CT for final post-procedure assessment. Our preliminary results suggest that high-quality RA is reliable and safe as a single technique for PVP guidance, control and post-procedure assessment. It permits fast and cost-effective procedures avoiding multi-modality imaging.

  4. Validity and reliability of the novel thyroid-specific quality of life questionnaire, ThyPRO

    DEFF Research Database (Denmark)

    Watt, Torquil; Hegedus, Laszlo; Grønvold, Mogens

    2010-01-01

    Appropriate scale validity and internal consistency reliability have recently been documented for the new thyroid-specific quality of life (QoL) patient-reported outcome (PRO) measure for benign thyroid disorders, the ThyPRO. However, before clinical use, clinical validity and test...

  5. Validity and reliability of a Nigerian-Yoruba version of the stroke-specific quality of life scale 2.0.

    Science.gov (United States)

    Odetunde, Marufat Oluyemisi; Akinpelu, Aderonke Omobonike; Odole, Adesola Christiana

    2017-10-19

    Psychometric evidence is necessary to establish scientific integrity and clinical usefulness of translations and cultural adaptations of the Stroke-Specific Quality of Life (SS-QoL) scale. However, the limited evidence on psychometrics of Yoruba version of SS-QoL 2.0 (SS-QoL(Y)) is a significant shortcoming. This study assessed the test-retest reliability, internal consistency, convergent, divergent, discriminant and known-group validity of the SS-QoL(Y). Yoruba version of the WHOQoL-BREF was used to test the convergent and divergent validity of the SS-QoL(Y) among 100 consenting stroke survivors. The WHOQoL-BREF and SS-QoL(Y) was administered randomly in order to eliminate bias. The test-retest reliability of the SS-QoL(Y) was carried out among 68 of the respondents within an interval of 7 days. All respondents were purposively recruited from selected secondary and tertiary health facilities in South-west Nigeria. Data were analysed using descriptive statistics of mean and standard deviation, and inferential statistics of Spearman correlation, Cronbach's alpha, Intra-class Correlation Coefficient (ICC), Independent t-test and One-way ANOVA. Alpha level was set at p validity of SS-QoL(Y) showed that items' r value ranged from 0.711 to 0.920 with their hypothesized domains. The scale demonstrated moderate to strong test-retest reliability with Intra-class correlation coefficient (ICC) for the domains and overall scores (r = 0.47 to 0.81) and moderate to high internal consistency (Cronbach's alpha =0.61 to 0.82) for domains scores. These correlations were also significant for the domains and overall scores (p validity, test-retest reliability and internal consistency of the Yoruba version of the Stroke Specific Quality of Life 2.0 are adequate while the convergent and divergent validity are low but acceptable. The SS-QoL(Y) is recommended for assessing health-related quality of life among Yoruba stroke survivors.

  6. Development of high-reliability control system for nuclear power plants

    International Nuclear Information System (INIS)

    Asami, K.; Yanai, K.; Hirose, H.; Ito, T.

    1983-01-01

    In Japan, many nuclear power generating plants are in operation and under construction. There is a general awareness of the problems in connection with nuclear power generation and strong emphasis is put on achieving highly reliable operation of nuclear power plants. Hitachi has developed a new high-reliability control system. NURECS-3000 (NUclear Power Plant High-REliability Control System), which is applied to the main control systems, such as the reactor feedwater control system, the reactor recirculation control system and the main turbine control system. The NURECS-3000 system was designed taking into account the fact that there will be failures, but the aim is for the system to continue to function correctly; it is therefore a fault-tolerant system. It has redundant components which can be completely isolated from each other in order to prevent fault propagation. The system has a hierarchical configuration, with a main controller, consisting of a triplex microcomputer system, and sub-loop controllers. Special care was taken to ensure the independence of these subsystems. Since most of the redundant system failures are caused by common-mode failures and the reliability of redundant systems depends on the reliability of the common-mode parts, the aim was to minimize these parts. (author)

  7. Linking Quality Assurance to Performance Improvement to Produce a High Reliability Organization

    International Nuclear Information System (INIS)

    Silvey, Andrea B.; Warrick, Louise H.

    2008-01-01

    Three basic change management models are currently used in healthcare to produce and sustain quality improvement. We have presented the context to determine where any particular organization stands within these paradigms. We also have introduced a change-management tool used to assess, plan, and monitor leadership effort and commitment to quality improvement and culture change activities, tracked as 'momentum for change.' This 'momentum' is measured at eight discrete levels, from recognizing a performance gap to officially implementing changes intended to improve quality

  8. High reliability megawatt transformer/rectifier

    Science.gov (United States)

    Zwass, Samuel; Ashe, Harry; Peters, John W.

    1991-01-01

    The goal of the two phase program is to develop the technology and design and fabricate ultralightweight high reliability DC to DC converters for space power applications. The converters will operate from a 5000 V dc source and deliver 1 MW of power at 100 kV dc. The power weight density goal is 0.1 kg/kW. The cycle to cycle voltage stability goals was + or - 1 percent RMS. The converter is to operate at an ambient temperature of -40 C with 16 minute power pulses and one hour off time. The uniqueness of the design in Phase 1 resided in the dc switching array which operates the converter at 20 kHz using Hollotron plasma switches along with a specially designed low loss, low leakage inductance and a light weight high voltage transformer. This approach reduced considerably the number of components in the converter thereby increasing the system reliability. To achieve an optimum transformer for this application, the design uses four 25 kV secondary windings to produce the 100 kV dc output, thus reducing the transformer leakage inductance, and the ac voltage stresses. A specially designed insulation system improves the high voltage dielectric withstanding ability and reduces the insulation path thickness thereby reducing the component weight. Tradeoff studies and tests conducted on scaled-down model circuits and using representative coil insulation paths have verified the calculated transformer wave shape parameters and the insulation system safety. In Phase 1 of the program a converter design approach was developed and a preliminary transformer design was completed. A fault control circuit was designed and a thermal profile of the converter was also developed.

  9. Kilowatt isotope power system. Phase II plan. Volume V. Safety, quality assurance and reliability

    International Nuclear Information System (INIS)

    1978-01-01

    The development of a Kilowatt Isotope Power System (KIPS) was begun in 1975 for the purpose of satisfying the power requirements of satellites in the 1980's. The KIPS is a 238 PuO 2 -fueled organic Rankine cycle turbine power system to provide a design output of 500 to 2000 W. Included in this volume are: launch and flight safety considerations; quality assurance techniques and procedures to be followed through system fabrication, assembly and inspection; and the reliability program made up of reliability prediction analysis, failure mode analysis and criticality analysis

  10. High Reliability Cryogenic Piezoelectric Valve Actuator, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Cryogenic fluid valves are subject to harsh exposure and actuators to drive these valves require robust performance and high reliability. DSM's piezoelectric...

  11. Effects of consensus training on the reliability of auditory perceptual ratings of voice quality.

    Science.gov (United States)

    Iwarsson, Jenny; Reinholt Petersen, Niels

    2012-05-01

    This study investigates the effect of consensus training of listeners on intrarater and interrater reliability and agreement of perceptual voice analysis. The use of such training, including a reference voice sample, could be assumed to make the internal standards held in memory common and more robust, which is of great importance to reduce the variability of auditory perceptual ratings. A prospective design with testing before and after training. Thirteen students of audiologopedics served as listening subjects. The ratings were made using a multidimensional protocol with four-point equal-appearing interval scales. The stimuli consisted of text reading by authentic dysphonic patients. The consensus training for each perceptual voice parameter included (1) definition, (2) underlying physiology, (3) presentation of carefully selected sound examples representing the parameter in three different grades followed by group discussions of perceived characteristics, and (4) practical exercises including imitation to make use of the listeners' proprioception. Intrarater reliability and agreement showed a marked improvement for intermittent aphonia but not for vocal fry. Interrater reliability was high for most parameters before training with a slight increase after training. Interrater agreement showed marked increases for most voice quality parameters as a result of the training. The results support the recommendation of specific consensus training, including use of a reference voice sample material, to calibrate, equalize, and stabilize the internal standards held in memory by the listeners. Copyright © 2012 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  12. Isolation of high quality RNA from pistachio (Pistacia vera L.) and other woody plants high in secondary metabolites.

    Science.gov (United States)

    Moazzam Jazi, Maryam; Rajaei, Saideh; Seyedi, Seyed Mahdi

    2015-10-01

    The quality and quantity of RNA are critical for successful downstream transcriptome-based studies such as microarrays and RNA sequencing (RNA-Seq). RNA isolation from woody plants, such as Pistacia vera, with very high amounts of polyphenols and polysaccharides is an enormous challenge. Here, we describe a highly efficient protocol that overcomes the limitations posed by poor quality and low yield of isolated RNA from pistachio and various recalcitrant woody plants. The key factors that resulted in a yield of 150 μg of high quality RNA per 200 mg of plant tissue include the elimination of phenol from the extraction buffer, raising the concentration of β-mercaptoethanol, long time incubation at 65 °C, and nucleic acid precipitation with optimized volume of NaCl and isopropyl alcohol. Also, the A260/A280 and A260/A230 of extracted RNA were about 1.9-2.1and 2.2-2.3, respectively, revealing the high purity. Since the isolated RNA passed highly stringent quality control standards for sensitive reactions, including RNA sequencing and real-time PCR, it can be considered as a reliable and cost-effective method for RNA extraction from woody plants.

  13. OSS reliability measurement and assessment

    CERN Document Server

    Yamada, Shigeru

    2016-01-01

    This book analyses quantitative open source software (OSS) reliability assessment and its applications, focusing on three major topic areas: the Fundamentals of OSS Quality/Reliability Measurement and Assessment; the Practical Applications of OSS Reliability Modelling; and Recent Developments in OSS Reliability Modelling. Offering an ideal reference guide for graduate students and researchers in reliability for open source software (OSS) and modelling, the book introduces several methods of reliability assessment for OSS including component-oriented reliability analysis based on analytic hierarchy process (AHP), analytic network process (ANP), and non-homogeneous Poisson process (NHPP) models, the stochastic differential equation models and hazard rate models. These measurement and management technologies are essential to producing and maintaining quality/reliable systems using OSS.

  14. The Behçet's Disease Quality of Life: Reliability and Validity of the Korean Version

    Science.gov (United States)

    Yi, Sang Won; Kim, Ji-Hae; Lim, Ki-Young; Bang, Dongsik; Lee, Sungnack

    2008-01-01

    Purpose The Behçet's Disease Quality of Life (BD-QoL) is a BD-specific measure developed in the UK. The aim of this study was to adapt the BD-QoL for use in Korea. Patients and Methods The translation was based on the guidelines for cross-cultural adaptation. A total of 201 Korean patients with BD participated in this study. To evaluate the psychometric properties, internal consistency and test-retest reliability were used. Factor analysis was performed to examine the construct validity. To provide further evidence for validity, the correlation of BD-QoL with the Clinical Activity Form for Korean Patients with BD (BDCAF-K) and the Center for Epidemiologic Studies-Depression (CES-D) scales was assessed. Results The Korean version had high internal consistency (Cronbach's alpha, 0.93) and test-retest reliability (r = 0.835). Factor analysis of the questionnaire revealed one interpretable factor as a general health-related quality of life factor. The Korean version significantly correlated with scores of CES-D (r = 0.749, p= 0.000), self-rating scale of well-being over the past 28 days (r = 0.446, p= 0.000), and BDCAF-K score (r = 0.502, p = 0.000). Conclusion Adaptation of the BD-QoL for use in Korea was successful. Together with the BDCAF-K, it may be a valuable tool for assessing the influence of interventions in BD patients and outcome in clinical trials. PMID:18972588

  15. Thai SF-36 health survey: tests of data quality, scaling assumptions, reliability and validity in healthy men and women

    Directory of Open Access Journals (Sweden)

    Sleigh Adrian

    2008-07-01

    Full Text Available Abstract Background Since its translation to Thai in 2000, the SF-36 Health Survey has been used extensively in many different clinical settings in Thailand. Its popularity has increased despite the absence of published evidence that the translated instrument satisfies scoring assumptions, the psychometric properties required for valid interpretation of the SF-36 summated ratings scales. The purpose of this paper was to examine these properties and to report on the reliability and validity of the Thai SF-36 in a non-clinical general population. Methods 1345 distance-education university students who live in all areas of Thailand completed a questionnaire comprising the Thai SF-36 (Version 1. Median age was 31 years. Psychometric tests recommended by the International Quality of Life Assessment Project were used. Results Data quality was satisfactory: questionnaire completion rate was high (97.5% and missing data rates were low ( Conclusion The summated ratings method can be used for scoring the Thai SF-36. The instrument was found to be reliable and valid for use in a general non-clinical population. Version 2 of the SF-36 could improve ceiling and floor effects in the role functioning scales. Further work is warranted to refine items that measure the concepts of social functioning, vitality and mental health to improve the reliability and discriminant validity of these scales.

  16. Sintered tantalum carbide coatings on graphite substrates: Highly reliable protective coatings for bulk and epitaxial growth

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Daisuke; Suzumura, Akitoshi; Shigetoh, Keisuke [Toyota Central R and D Labs., Inc., Nagakute, Aichi 480-1192 (Japan)

    2015-02-23

    Highly reliable low-cost protective coatings have been sought after for use in crucibles and susceptors for bulk and epitaxial film growth processes involving wide bandgap materials. Here, we propose a production technique for ultra-thick (50–200 μmt) tantalum carbide (TaC) protective coatings on graphite substrates, which consists of TaC slurry application and subsequent sintering processes, i.e., a wet ceramic process. Structural analysis of the sintered TaC layers indicated that they have a dense granular structure containing coarse grain with sizes of 10–50 μm. Furthermore, no cracks or pinholes penetrated through the layers, i.e., the TaC layers are highly reliable protective coatings. The analysis also indicated that no plastic deformation occurred during the production process, and the non-textured crystalline orientation of the TaC layers is the origin of their high reliability and durability. The TaC-coated graphite crucibles were tested in an aluminum nitride (AlN) sublimation growth process, which involves extremely corrosive conditions, and demonstrated their practical reliability and durability in the AlN growth process as a TaC-coated graphite. The application of the TaC-coated graphite materials to crucibles and susceptors for use in bulk AlN single crystal growth, bulk silicon carbide (SiC) single crystal growth, chemical vapor deposition of epitaxial SiC films, and metal-organic vapor phase epitaxy of group-III nitrides will lead to further improvements in crystal quality and reduced processing costs.

  17. Sintered tantalum carbide coatings on graphite substrates: Highly reliable protective coatings for bulk and epitaxial growth

    International Nuclear Information System (INIS)

    Nakamura, Daisuke; Suzumura, Akitoshi; Shigetoh, Keisuke

    2015-01-01

    Highly reliable low-cost protective coatings have been sought after for use in crucibles and susceptors for bulk and epitaxial film growth processes involving wide bandgap materials. Here, we propose a production technique for ultra-thick (50–200 μmt) tantalum carbide (TaC) protective coatings on graphite substrates, which consists of TaC slurry application and subsequent sintering processes, i.e., a wet ceramic process. Structural analysis of the sintered TaC layers indicated that they have a dense granular structure containing coarse grain with sizes of 10–50 μm. Furthermore, no cracks or pinholes penetrated through the layers, i.e., the TaC layers are highly reliable protective coatings. The analysis also indicated that no plastic deformation occurred during the production process, and the non-textured crystalline orientation of the TaC layers is the origin of their high reliability and durability. The TaC-coated graphite crucibles were tested in an aluminum nitride (AlN) sublimation growth process, which involves extremely corrosive conditions, and demonstrated their practical reliability and durability in the AlN growth process as a TaC-coated graphite. The application of the TaC-coated graphite materials to crucibles and susceptors for use in bulk AlN single crystal growth, bulk silicon carbide (SiC) single crystal growth, chemical vapor deposition of epitaxial SiC films, and metal-organic vapor phase epitaxy of group-III nitrides will lead to further improvements in crystal quality and reduced processing costs

  18. High pressure, high current, low inductance, high reliability sealed terminals

    Science.gov (United States)

    Hsu, John S [Oak Ridge, TN; McKeever, John W [Oak Ridge, TN

    2010-03-23

    The invention is a terminal assembly having a casing with at least one delivery tapered-cone conductor and at least one return tapered-cone conductor routed there-through. The delivery and return tapered-cone conductors are electrically isolated from each other and positioned in the annuluses of ordered concentric cones at an off-normal angle. The tapered cone conductor service can be AC phase conductors and DC link conductors. The center core has at least one service conduit of gate signal leads, diagnostic signal wires, and refrigerant tubing routed there-through. A seal material is in direct contact with the casing inner surface, the tapered-cone conductors, and the service conduits thereby hermetically filling the interstitial space in the casing interior core and center core. The assembly provides simultaneous high-current, high-pressure, low-inductance, and high-reliability service.

  19. Human reliability in high dose rate afterloading radiotherapy based on FMECA

    International Nuclear Information System (INIS)

    Deng Jun; Fan Yaohua; Yue Baorong; Wei Kedao; Ren Fuli

    2012-01-01

    Objective: To put forward reasonable and feasible recommendations against the procedure with relative high risk during the high dose rate (HDR) afterloading radiotherapy, so as to enhance its clinical application safety, through studying the human reliability in the process of carrying out the HDR afterloading radiotherapy. Methods: Basic data were collected by on-site investigation and process analysis as well as expert evaluation. Failure mode, effect and criticality analysis (FMECA) employed to study the human reliability in the execution of HDR afterloading radiotherapy. Results: The FMECA model of human reliability for HDR afterloading radiotherapy was established, through which 25 procedures with relative high risk index were found,accounting for 14.1% of total 177 procedures. Conclusions: FMECA method in human reliability study for HDR afterloading radiotherapy is feasible. The countermeasures are put forward to reduce the human error, so as to provide important basis for enhancing clinical application safety of HDR afterloading radiotherapy. (authors)

  20. Reliability of large superconducting magnets through design

    International Nuclear Information System (INIS)

    Henning, C.D.

    1980-01-01

    As superconducting magnet systems grow larger and become the central component of major systems involving fusion, magnetohydrodynamics, and high-energy physics, their reliability must be commensurate with the enormous capital investment in the projects. Although the magnet may represent only 15% of the cost of a large system such as the Mirror Fusion Test Facility, its failure would be catastrophic to the entire investment. Effective quality control during construction is one method of ensuring success. However, if the design is unforgiving, even an inordinate amount of effort expended on quality control may be inadequate. Creative design is the most effective way of ensuring magnet reliability and providing a reasonable limit on the amount of quality control needed. For example, by subjecting the last drawing operation is superconductor manufacture to a stress larger than the magnet design stress, a 100% proof test is achieved; cabled conductors offer mechanical redundancy, as do some methods of conductor joining; ground-plane insulation should be multilayered to prevent arcs, and interturn and interlayer insulation spaced to be compatible with the self-extinguishing of arcs during quench voltages; electrical leads should be thermally protected; and guard vacuum spaces can be incorporated to control helium leaks. Many reliable design options are known to magnet designers. These options need to be documented and organized to produce a design guide. Eventually, standard procedures, safety factors, and design codes can lead to reliability in magnets comparable to that obtained in pressure vessels and other structures. Wihout such reliability, large-scale applications in major systems employing magnetic fusion energy, magnetohydrodynamics, or high-energy physics would present unacceptable economic risks

  1. Reliability studies of high operating temperature MCT photoconductor detectors

    Science.gov (United States)

    Wang, Wei; Xu, Jintong; Zhang, Yan; Li, Xiangyang

    2010-10-01

    This paper concerns HgCdTe (MCT) infrared photoconductor detectors with high operating temperature. The near room temperature operation of detectors have advantages of light weight, less cost and convenient usage. Their performances are modest and they suffer from reliable problems. These detectors face with stability of the package, chip bonding area and passivation layers. It's important to evaluate and improve the reliability of such detectors. Defective detectors were studied with SEM(Scanning electron microscope) and microscopy. Statistically significant differences were observed between the influence of operating temperature and the influence of humidity. It was also found that humility has statistically significant influence upon the stability of the chip bonding and passivation layers, and the amount of humility isn't strongly correlated to the damage on the surface. Considering about the commonly found failures modes in detectors, special test structures were designed to improve the reliability of detectors. An accelerated life test was also implemented to estimate the lifetime of the high operating temperature MCT photoconductor detectors.

  2. Electric Power quality Analysis in research reactor: Impacts on nuclear safety assessment and electrical distribution reliability

    International Nuclear Information System (INIS)

    Touati, Said; Chennai, Salim; Souli, Aissa

    2015-01-01

    The increased requirements on supervision, control, and performance in modern power systems make power quality monitoring a common practise for utilities. Large databases are created and automatic processing of the data is required for fast and effective use of the available information. Aim of the work presented in this paper is the development of tools for analysis of monitoring power quality data and in particular measurements of voltage and currents in various level of electrical power distribution. The study is extended to evaluate the reliability of the electrical system in nuclear plant. Power Quality is a measure of how well a system supports reliable operation of its loads. A power disturbance or event can involve voltage, current, or frequency. Power disturbances can originate in consumer power systems, consumer loads, or the utility. The effect of power quality problems is the loss power supply leading to severe damage to equipments. So, we try to track and improve system reliability. The assessment can be focused on the study of impact of short circuits on the system, harmonics distortion, power factor improvement and effects of transient disturbances on the Electrical System during motor starting and power system fault conditions. We focus also on the review of the Electrical System design against the Nuclear Directorate Safety Assessment principles, including those extended during the last Fukushima nuclear accident. The simplified configuration of the required system can be extended from this simple scheme. To achieve these studies, we have used a demo ETAP power station software for several simulations. (authors)

  3. Electric Power quality Analysis in research reactor: Impacts on nuclear safety assessment and electrical distribution reliability

    Energy Technology Data Exchange (ETDEWEB)

    Touati, Said; Chennai, Salim; Souli, Aissa [Nuclear Research Centre of Birine, Ain Oussera, Djelfa Province (Algeria)

    2015-07-01

    The increased requirements on supervision, control, and performance in modern power systems make power quality monitoring a common practise for utilities. Large databases are created and automatic processing of the data is required for fast and effective use of the available information. Aim of the work presented in this paper is the development of tools for analysis of monitoring power quality data and in particular measurements of voltage and currents in various level of electrical power distribution. The study is extended to evaluate the reliability of the electrical system in nuclear plant. Power Quality is a measure of how well a system supports reliable operation of its loads. A power disturbance or event can involve voltage, current, or frequency. Power disturbances can originate in consumer power systems, consumer loads, or the utility. The effect of power quality problems is the loss power supply leading to severe damage to equipments. So, we try to track and improve system reliability. The assessment can be focused on the study of impact of short circuits on the system, harmonics distortion, power factor improvement and effects of transient disturbances on the Electrical System during motor starting and power system fault conditions. We focus also on the review of the Electrical System design against the Nuclear Directorate Safety Assessment principles, including those extended during the last Fukushima nuclear accident. The simplified configuration of the required system can be extended from this simple scheme. To achieve these studies, we have used a demo ETAP power station software for several simulations. (authors)

  4. Improvements in the consistency of fabrication and the reliability of nuclear fuels through quality assurance

    International Nuclear Information System (INIS)

    Sifferlen, R.

    1976-01-01

    By establishing correlations between rejection level and fabrication parameters, quality assurance can guide corrective action for improving the consistency of fabrication and the reliability of fuel elements. The author cites examples relating to the quality of the uranium in metallic fuels, the influence of the parent metal on the welding of zirconium alloys, the behaviour of the springs inside the cladding during the welding of plugs and the behaviour of uranium oxide pellets. (author)

  5. Reliability and Validity of SERVQUAL Scores Used To Evaluate Perceptions of Library Service Quality.

    Science.gov (United States)

    Thompson, Bruce; Cook, Colleen

    Research libraries are increasingly supplementing collection counts with perceptions of service quality as indices of status and productivity. The present study was undertaken to explore the reliability and validity of scores from the SERVQUAL measurement protocol (A. Parasuraman and others, 1991), which has previously been used in this type of…

  6. [Development and reliability evaluation of an instrument to measure health-related quality of life in independent elderly].

    Science.gov (United States)

    Lima, Maria José Barbosa de; Portela, Margareth Crisóstomo

    2010-08-01

    This study presents an instrument, the health-related quality of life (HRQOL) profile for independent elderly, to measure the health-related quality of life of the functionally independent elderly assisted in the outpatient setting, based on the adaptation of four validated scales: Short-Form Health Survey (SF-36), Duke-UNC Health Profile (DUHP), Sickness Impact Profile (SIP), and Nottingham Health Profile (NHP). The study also evaluates the instrument's reliability based on its use by two different observers with a 15-day interval. The instrument includes five dimensions (health perception, symptoms, physical function, psychological function, and social function) and 45 items. Reliability evaluation of the QUASI instrument was based on interviews with 142 elderly outpatients in the city of Rio de Janeiro, Brazil. Prevalence-adjusted kappa statistic was used to assess all 45 items. Correlation was also calculated between overall scores and scores on individual dimensions. In the reliability evaluation, 39 of the 45 items showed prevalence-adjusted kappa greater than 0.60.

  7. Reliable and repeatable bonding technology for high temperature automotive power modules for electrified vehicles

    International Nuclear Information System (INIS)

    Yoon, Sang Won; Shiozaki, Koji; Glover, Michael D; Mantooth, H Alan

    2013-01-01

    This paper presents the feasibility of highly reliable and repeatable copper–tin transient liquid phase (Cu–Sn TLP) bonding as applied to die attachment in high temperature operational power modules. Electrified vehicles are attracting particular interest as eco-friendly vehicles, but their power modules are challenged because of increasing power densities which lead to high temperatures. Such high temperature operation addresses the importance of advanced bonding technology that is highly reliable (for high temperature operation) and repeatable (for fabrication of advanced structures). Cu–Sn TLP bonding is employed herein because of its high remelting temperature and desirable thermal and electrical conductivities. The bonding starts with a stack of Cu–Sn–Cu metal layers that eventually transforms to Cu–Sn alloys. As the alloys have melting temperatures (Cu 3 Sn: > 600 °C, Cu 6 Sn 5 : > 400 °C) significantly higher than the process temperature, the process can be repeated without damaging previously bonded layers. A Cu–Sn TLP bonding process was developed using thin Sn metal sheets inserted between copper layers on silicon die and direct bonded copper substrates, emulating the process used to construct automotive power modules. Bond quality is characterized using (1) proof-of-concept fabrication, (2) material identification using scanning electron microscopy and energy-dispersive x-ray spectroscopy analysis, and (3) optical analysis using optical microscopy and scanning acoustic microscope. The feasibility of multiple-sided Cu–Sn TLP bonding is demonstrated by the absence of bondline damage in multiple test samples fabricated with double- or four-sided bonding using the TLP bonding process. (paper)

  8. Performance and reliability of TPE-2 device with pulsed high power source

    International Nuclear Information System (INIS)

    Sato, Y.; Takeda, S.; Kiyama, S.

    1987-01-01

    The performance and the reliability of TPE-2 device with pulsed high power sources are described. To obtain the stable high beta plasma, the reproducibility and the reliability of the pulsed power sources must be maintained. A new power crowbar system with high efficiency and the switches with low jitter time are adopted to the bank system. A monitor system which always watches the operational states of the switches is developed too, and applied for the fast rising capacitor banks of TPE-2 device. The reliable operation for the bank has been realized, based on the data of switch monitor system

  9. Systematic evaluation of the teaching qualities of Obstetrics and Gynecology faculty: reliability and validity of the SETQ tools

    NARCIS (Netherlands)

    van der Leeuw, Renée; Lombarts, Kiki; Heineman, Maas Jan; Arah, Onyebuchi

    2011-01-01

    The importance of effective clinical teaching for the quality of future patient care is globally understood. Due to recent changes in graduate medical education, new tools are needed to provide faculty with reliable and individualized feedback on their teaching qualities. This study validates two

  10. High reliability low jitter 80 kV pulse generator

    Directory of Open Access Journals (Sweden)

    M. E. Savage

    2009-08-01

    Full Text Available Switching can be considered to be the essence of pulsed power. Time accurate switch/trigger systems with low inductance are useful in many applications. This article describes a unique switch geometry coupled with a low-inductance capacitive energy store. The system provides a fast-rising high voltage pulse into a low impedance load. It can be challenging to generate high voltage (more than 50 kilovolts into impedances less than 10  Ω, from a low voltage control signal with a fast rise time and high temporal accuracy. The required power amplification is large, and is usually accomplished with multiple stages. The multiple stages can adversely affect the temporal accuracy and the reliability of the system. In the present application, a highly reliable and low jitter trigger generator was required for the Z pulsed-power facility [M. E. Savage, L. F. Bennett, D. E. Bliss, W. T. Clark, R. S. Coats,J. M. Elizondo, K. R. LeChien, H. C. Harjes, J. M. Lehr, J. E. Maenchen, D. H. McDaniel, M. F. Pasik, T. D. Pointon, A. C. Owen, D. B. Seidel, D. L. Smith, B. S. Stoltzfus, K. W. Struve, W. A. Stygar, L. K. Warne, and J. R. Woodworth, 2007 IEEE Pulsed Power Conference, Albuquerque, NM (IEEE, Piscataway, NJ, 2007, p. 979]. The large investment in each Z experiment demands low prefire probability and low jitter simultaneously. The system described here is based on a 100 kV DC-charged high-pressure spark gap, triggered with an ultraviolet laser. The system uses a single optical path for simultaneously triggering two parallel switches, allowing lower inductance and electrode erosion with a simple optical system. Performance of the system includes 6 ns output rise time into 5.6  Ω, 550 ps one-sigma jitter measured from the 5 V trigger to the high voltage output, and misfire probability less than 10^{-4}. The design of the system and some key measurements will be shown in the paper. We will discuss the

  11. Thai SF-36 health survey: tests of data quality, scaling assumptions, reliability and validity in healthy men and women.

    Science.gov (United States)

    Lim, Lynette L-Y; Seubsman, Sam-Ang; Sleigh, Adrian

    2008-07-18

    Since its translation to Thai in 2000, the SF-36 Health Survey has been used extensively in many different clinical settings in Thailand. Its popularity has increased despite the absence of published evidence that the translated instrument satisfies scoring assumptions, the psychometric properties required for valid interpretation of the SF-36 summated ratings scales. The purpose of this paper was to examine these properties and to report on the reliability and validity of the Thai SF-36 in a non-clinical general population. 1345 distance-education university students who live in all areas of Thailand completed a questionnaire comprising the Thai SF-36 (Version 1). Median age was 31 years. Psychometric tests recommended by the International Quality of Life Assessment Project were used. Data quality was satisfactory: questionnaire completion rate was high (97.5%) and missing data rates were low (Vitality scale correlated better with the Mental Health scale than with itself, possibly because a healthy mental state is central to the concept of vitality in Thailand. The summated ratings method can be used for scoring the Thai SF-36. The instrument was found to be reliable and valid for use in a general non-clinical population. Version 2 of the SF-36 could improve ceiling and floor effects in the role functioning scales. Further work is warranted to refine items that measure the concepts of social functioning, vitality and mental health to improve the reliability and discriminant validity of these scales.

  12. The Impact of the Reliability of Teleinformation Systems on the Quality of Transmitted Information

    Directory of Open Access Journals (Sweden)

    Stawowy Marek

    2016-10-01

    Full Text Available The work describes the impact the reliability of the information quality IQ for information and communication systems. One of the components of IQ is the reliability properties such as relativity, accuracy, timeliness, completeness, consistency, adequacy, accessibility, credibility, congruence. Each of these components of IQ is independent and to properly estimate the value of IQ, use one of the methods of modeling uncertainty. In this article, we used a hybrid method that has been developed jointly by one of the authors. This method is based on the mathematical theory of evidence know as Dempstera-Shafera (DS theory and serial links of dependent hybrid named IQ (hyb.

  13. The Berg Balance Scale has high intra- and inter-rater reliability but absolute reliability varies across the scale: a systematic review.

    Science.gov (United States)

    Downs, Stephen; Marquez, Jodie; Chiarelli, Pauline

    2013-06-01

    What is the intra-rater and inter-rater relative reliability of the Berg Balance Scale? What is the absolute reliability of the Berg Balance Scale? Does the absolute reliability of the Berg Balance Scale vary across the scale? Systematic review with meta-analysis of reliability studies. Any clinical population that has undergone assessment with the Berg Balance Scale. Relative intra-rater reliability, relative inter-rater reliability, and absolute reliability. Eleven studies involving 668 participants were included in the review. The relative intrarater reliability of the Berg Balance Scale was high, with a pooled estimate of 0.98 (95% CI 0.97 to 0.99). Relative inter-rater reliability was also high, with a pooled estimate of 0.97 (95% CI 0.96 to 0.98). A ceiling effect of the Berg Balance Scale was evident for some participants. In the analysis of absolute reliability, all of the relevant studies had an average score of 20 or above on the 0 to 56 point Berg Balance Scale. The absolute reliability across this part of the scale, as measured by the minimal detectable change with 95% confidence, varied between 2.8 points and 6.6 points. The Berg Balance Scale has a higher absolute reliability when close to 56 points due to the ceiling effect. We identified no data that estimated the absolute reliability of the Berg Balance Scale among participants with a mean score below 20 out of 56. The Berg Balance Scale has acceptable reliability, although it might not detect modest, clinically important changes in balance in individual subjects. The review was only able to comment on the absolute reliability of the Berg Balance Scale among people with moderately poor to normal balance. Copyright © 2013 Australian Physiotherapy Association. Published by .. All rights reserved.

  14. Reliability and validity of the Malay translated version of diabetes quality of life for youth questionnaire

    Directory of Open Access Journals (Sweden)

    Jamaiyah H

    2013-05-01

    Full Text Available Introduction: Many studies reported poorer quality of life (QoL in youth with diabetes compared to healthy peers. One of the tools used is the Diabetes Quality of Life for Youth (DQoLY questionnaire in English. A validated instrument in Malay is needed to assess the perception of QoL among youth with diabetes in Malaysia. Objective: To translate the modified version, i.e., the DQoLY questionnaire,into Malay and determine its reliability and validity.Methods: Translation and back-translation were used. An expert panel reviewed the translated version for conceptual and content equivalence. The final version was then administered to youths with type 1 diabetes mellitus from the universities and Ministry of Health hospitals between August 2006 and September 2007. Reliability was analysed using Cronbach’s alpha, while validity was confirmed using concurrent validity (HbA1c and self-rated health score.Results: A total of 82 youths with type 1 diabetes (38 males aged 10-18 years were enrolled from eight hospitals. The reliability of overall questionnaire was 0.917, and the reliabilities of the three domains ranged from 0.832 to 0.867. HbA1c was positively correlated with worry (p=0.03. The self-rated health score was found to have significant negative correlation with the “satisfaction” (p=0.013 and “impact” (p=0.007 domains.Conclusion: The Malay translated version of DQoLY questionnaire was reliable and valid to be used among youths with type 2 diabetes in Malaysia.

  15. Why do quality and reliability feedback loops not always work in practice: a case study

    NARCIS (Netherlands)

    Molenaar, P.A.; Huijben, A.J.M.; Bouwhuis, D.G.; Brombacher, A.C.

    2002-01-01

    The increasing competition in the market of consumer electronics forces industry to simultaneously improve the functionability, reliability and costs of their products. Due to the strong dynamics of this field an important measure in improving product quality is the feedback of information on actual

  16. Improving patient safety: patient-focused, high-reliability team training.

    Science.gov (United States)

    McKeon, Leslie M; Cunningham, Patricia D; Oswaks, Jill S Detty

    2009-01-01

    Healthcare systems are recognizing "human factor" flaws that result in adverse outcomes. Nurses work around system failures, although increasing healthcare complexity makes this harder to do without risk of error. Aviation and military organizations achieve ultrasafe outcomes through high-reliability practice. We describe how reliability principles were used to teach nurses to improve patient safety at the front line of care. Outcomes include safety-oriented, teamwork communication competency; reflections on safety culture and clinical leadership are discussed.

  17. A High Reliability Frequency Stabilized Semiconductor Laser Source, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Ultrastable, narrow linewidth, high reliability MOPA sources are needed for high performance LIDARs in NASA for, wind speed measurement, surface topography and earth...

  18. Quality and reliability assurance of electronic components in small-scale and middle-sized plants

    International Nuclear Information System (INIS)

    Becker, P.

    1982-01-01

    Electronic components are forever finding their way into new fields of application and have an ever increasing influence on the quality and reliability of the products in which they are used. The user has very negligible influence on the production methods used for the manufacture of the components and the element properties. (orig.) [de

  19. Measuring the reliability and validity of the Greek edition of the Diabetes Quality of Life Brief Clinical Inventory.

    Science.gov (United States)

    Rekleiti, Maria; Souliotis, Kyriakos; Sarafis, Pavlos; Kyriazis, Ioannis; Tsironi, Maria

    2018-06-01

    The present study focuses on studying the validity and reliability of the Greek edition of DQOL-BCI. DQOL-BCI includes 15 questions-elements that are evaluated on a 5-grade scale like Likert and two general form-shapes. The translation process was conducted in conformity with the guidelines of EuroQol group. A non-random sample of 65 people-patients diagnosed with diabetes I and II was selected. The questionnaire that was used to collect the data was the translated version of DQOL-BCI, and included the demographic characteristics of the interviewees. The content validity of DQOL-BCI was re-examined from a team of five experts (expert panel) for qualitative and quantitative performance. The completion of the questionnaire was done via a personal interview. The sample consisted of 58 people (35 men and 23 women, 59.9 ± 10.9 years). The translation of the questionnaire was found appropriate in accordance to the peculiarities of the Greek language and culture. The largest deviation of values is observed in QOL1 (1.71) in comparison to QOL6 (2.98). The difference between the standard deviations is close to 0.6. The statistics results of the tests showed satisfactory content validity and high construct validity, while the high values for Cronbach alpha index (0.95) reveal high reliability and internal consistency. The Greek version of DQOL-BCI has acceptable psychometric properties and appears to demonstrate high internal reliability and satisfactory construct validity, which allows its use as an important tool in evaluating the quality of life of diabetic patients in relation to their health. Copyright © 2018. Published by Elsevier B.V.

  20. On the design of high-rise buildings with a specified level of reliability

    Science.gov (United States)

    Dolganov, Andrey; Kagan, Pavel

    2018-03-01

    High-rise buildings have a specificity, which significantly distinguishes them from traditional buildings of high-rise and multi-storey buildings. Steel structures in high-rise buildings are advisable to be used in earthquake-proof regions, since steel, due to its plasticity, provides damping of the kinetic energy of seismic impacts. These aspects should be taken into account when choosing a structural scheme of a high-rise building and designing load-bearing structures. Currently, modern regulatory documents do not quantify the reliability of structures. Although the problem of assigning an optimal level of reliability has existed for a long time. The article shows the possibility of designing metal structures of high-rise buildings with specified reliability. Currently, modern regulatory documents do not quantify the reliability of high-rise buildings. Although the problem of assigning an optimal level of reliability has existed for a long time. It is proposed to establish the value of reliability 0.99865 (3σ) for constructions of buildings and structures of a normal level of responsibility in calculations for the first group of limiting states. For increased (construction of high-rise buildings) and reduced levels of responsibility for the provision of load-bearing capacity, it is proposed to assign respectively 0.99997 (4σ) and 0.97725 (2σ). The coefficients of the use of the cross section of a metal beam for different levels of security are given.

  1. Reliability-based design optimization via high order response surface method

    International Nuclear Information System (INIS)

    Li, Hong Shuang

    2013-01-01

    To reduce the computational effort of reliability-based design optimization (RBDO), the response surface method (RSM) has been widely used to evaluate reliability constraints. We propose an efficient methodology for solving RBDO problems based on an improved high order response surface method (HORSM) that takes advantage of an efficient sampling method, Hermite polynomials and uncertainty contribution concept to construct a high order response surface function with cross terms for reliability analysis. The sampling method generates supporting points from Gauss-Hermite quadrature points, which can be used to approximate response surface function without cross terms, to identify the highest order of each random variable and to determine the significant variables connected with point estimate method. The cross terms between two significant random variables are added to the response surface function to improve the approximation accuracy. Integrating the nested strategy, the improved HORSM is explored in solving RBDO problems. Additionally, a sampling based reliability sensitivity analysis method is employed to reduce the computational effort further when design variables are distributional parameters of input random variables. The proposed methodology is applied on two test problems to validate its accuracy and efficiency. The proposed methodology is more efficient than first order reliability method based RBDO and Monte Carlo simulation based RBDO, and enables the use of RBDO as a practical design tool.

  2. Reliability and validity of a survey to measure bowel function and quality of life in long-term rectal cancer survivors.

    Science.gov (United States)

    Wendel, Christopher S; Grant, Marcia; Herrinton, Lisa; Temple, Larissa K F; Hornbrook, Mark C; McMullen, Carmit K; Bulkley, Joanna E; Altschuler, Andrea; Krouse, Robert S

    2014-12-01

    Examination of reliability and validity of a specialized health-related quality of life questionnaire for rectal cancer (RC) survivors (≥5 years post-diagnosis). We mailed 1,063 Kaiser Permanente (KP) RC survivors (313 ostomy and 750 anastomosis) a questionnaire containing the Modified City of Hope Quality of Life-Ostomy (mCOH-QOL-O), SF-12v2, Duke-UNC Functional Social Support Questionnaire (FSSQ), and Memorial Sloan-Kettering Cancer Center Bowel Function Index (BFI). We adapted certain BFI items for use by subjects with intestinal ostomies. We evaluated reliability for all instruments with inter-item correlations and Cronbach's alpha. We assessed construct validity only for the BFI in the ostomy group, because such use has not been reported. The overall response rate was 60.5 % (577 respondents/953 eligible). Compared with non-responders, participants were on average 2 years younger and more likely non-Hispanic white, resided in educationally non-deprived areas, and had KP membership through a group. The mCOH-QOL-O, SF-12, and FSSQ were found to be highly reliable for RC survivors. In the ostomy group, BFI Urgency/Soilage and Dietary subscales were found to be reliable, but Frequency was not. Factor analysis supported the construct of Urgency/Soilage and Dietary subscales in the ostomy group, although one item had a moderate correlation with all three factors. The BFI also demonstrated good concurrent validity with other instruments in the ostomy group. With possible exception of the BFI Frequency subscale in populations with ostomies, components of our survey can be used for the entire population of RC survivors, no matter whether they received anastomosis or ostomy.

  3. Highly-reliable laser diodes and modules for spaceborne applications

    Science.gov (United States)

    Deichsel, E.

    2017-11-01

    Laser applications become more and more interesting in contemporary missions such as earth observations or optical communication in space. One of these applications is light detection and ranging (LIDAR), which comprises huge scientific potential in future missions. The Nd:YAG solid-state laser of such a LIDAR system is optically pumped using 808nm emitting pump sources based on semiconductor laser-diodes in quasi-continuous wave (qcw) operation. Therefore reliable and efficient laser diodes with increased output powers are an important requirement for a spaceborne LIDAR-system. In the past, many tests were performed regarding the performance and life-time of such laser-diodes. There were also studies for spaceborne applications, but a test with long operation times at high powers and statistical relevance is pending. Other applications, such as science packages (e.g. Raman-spectroscopy) on planetary rovers require also reliable high-power light sources. Typically fiber-coupled laser diode modules are used for such applications. Besides high reliability and life-time, designs compatible to the harsh environmental conditions must be taken in account. Mechanical loads, such as shock or strong vibration are expected due to take-off or landing procedures. Many temperature cycles with high change rates and differences must be taken in account due to sun-shadow effects in planetary orbits. Cosmic radiation has strong impact on optical components and must also be taken in account. Last, a hermetic sealing must be considered, since vacuum can have disadvantageous effects on optoelectronics components.

  4. Utilizing leadership to achieve high reliability in the delivery of perinatal care

    Directory of Open Access Journals (Sweden)

    Parrotta C

    2012-11-01

    Full Text Available Carmen Parrotta,1 William Riley,1 Les Meredith21School of Public Health, University of Minnesota, Minneapolis, MN, 2Premier Insurance Management Services Inc, Charlotte, NC, USAAbstract: Highly reliable care requires standardization of clinical practices and is a prerequisite for patient safety. However, standardization in complex hospital settings is extremely difficult to attain and health care leaders are challenged to create care delivery processes that ensure patient safety. Moreover, once high reliability is achieved in a hospital unit, it must be maintained to avoid process deterioration. This case study examines an intervention to implement care bundles (a collection of evidence-based practices in four hospitals to achieve standardized care in perinatal units. The results show different patterns in the rate and magnitude of change within the hospitals to achieve high reliability. The study is part of a larger nationwide study of 16 hospitals to improve perinatal safety. Based on the findings, we discuss the role of leadership for implementing and sustaining high reliability to ensure freedom from unintended injury.Keywords: care bundles, evidence-based practice, standardized care, process improvement

  5. To the problem of reliability of high-voltage accelerators for industrial purposes

    International Nuclear Information System (INIS)

    Al'bertinskij, B.I.; Svin'in, M.P.; Tsepakin, S.G.

    1979-01-01

    Statistical data characterizing the reliability of ELECTRON and AVRORA-2 type accelerators are presented. Used as a reliability index was the mean time to failure of the main accelerator units. The analysis of accelerator failures allowed a number of conclusions to be drawn. The high failure rate level is connected with inadequate training of the servicing personnel and a natural period of equipment adjustment. The mathematical analysis of the failure rate showed that the main responsibility for insufficient high reliability rests with selenium diodes which are employed in the high voltage power supply. Substitution of selenium diodes by silicon ones increases time between failures. It is shown that accumulation and processing of operational statistical data will permit more accurate prediction of the reliability of produced high-voltage accelerators, make it possible to cope with the problems of planning optimal, in time, preventive inspections and repair, and to select optimal safety factors and test procedures n time, preventive inspections and repair, and to select optimal safety factors and test procedures n time, prevent

  6. Reliability of muscle strength assessment in chronic post-stroke hemiparesis: a systematic review and meta-analysis.

    Science.gov (United States)

    Rabelo, Michelle; Nunes, Guilherme S; da Costa Amante, Natália Menezes; de Noronha, Marcos; Fachin-Martins, Emerson

    2016-02-01

    Muscle weakness is the main cause of motor impairment among stroke survivors and is associated with reduced peak muscle torque. To systematically investigate and organize the evidence of the reliability of muscle strength evaluation measures in post-stroke survivors with chronic hemiparesis. Two assessors independently searched four electronic databases in January 2014 (Medline, Scielo, CINAHL, Embase). Inclusion criteria comprised studies on reliability on muscle strength assessment in adult post-stroke patients with chronic hemiparesis. We extracted outcomes from included studies about reliability data, measured by intraclass correlation coefficient (ICC) and/or similar. The meta-analyses were conducted only with isokinetic data. Of 450 articles, eight articles were included for this review. After quality analysis, two studies were considered of high quality. Five different joints were analyzed within the included studies (knee, hip, ankle, shoulder, and elbow). Their reliability results varying from low to very high reliability (ICCs from 0.48 to 0.99). Results of meta-analysis for knee extension varying from high to very high reliability (pooled ICCs from 0.89 to 0.97), for knee flexion varying from high to very high reliability (pooled ICCs from 0.84 to 0.91) and for ankle plantar flexion showed high reliability (pooled ICC = 0.85). Objective muscle strength assessment can be reliably used in lower and upper extremities in post-stroke patients with chronic hemiparesis.

  7. Reliability of high power electron accelerators for radiation processing

    Energy Technology Data Exchange (ETDEWEB)

    Zimek, Z. [Department of Radiation Chemistry and Technology, Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    2011-07-01

    Accelerators applied for radiation processing are installed in industrial facilities where accelerator availability coefficient should be at the level of 95% to fulfill requirements according to industry standards. Usually the exploitation of electron accelerator reviles the number of short and few long lasting failures. Some technical shortages can be overcome by practical implementation the experience gained in accelerator technology development by different accelerator manufactures. The reliability/availability of high power accelerators for application in flue gas treatment process must be dramatically improved to meet industrial standards. Support of accelerator technology dedicated for environment protection should be provided by governmental and international institutions to overcome accelerator reliability/availability problem and high risk and low direct profit in this particular application. (author)

  8. Reliability of high power electron accelerators for radiation processing

    International Nuclear Information System (INIS)

    Zimek, Z.

    2011-01-01

    Accelerators applied for radiation processing are installed in industrial facilities where accelerator availability coefficient should be at the level of 95% to fulfill requirements according to industry standards. Usually the exploitation of electron accelerator reviles the number of short and few long lasting failures. Some technical shortages can be overcome by practical implementation the experience gained in accelerator technology development by different accelerator manufactures. The reliability/availability of high power accelerators for application in flue gas treatment process must be dramatically improved to meet industrial standards. Support of accelerator technology dedicated for environment protection should be provided by governmental and international institutions to overcome accelerator reliability/availability problem and high risk and low direct profit in this particular application. (author)

  9. Production of high quality water for oil sands application

    Energy Technology Data Exchange (ETDEWEB)

    Beaudette-Hodsman, C.; Macleod, B. [Pall Corp., Mississauga, ON (Canada); Venkatadri, R. [Pall Corp., East Hills, NY (United States)

    2008-10-15

    This paper described a pressurized microfiltration membrane system installed at an oil sands extraction site in Alberta. The system was designed to complement a reverse osmosis (RO) system installed at the site to produce the high quality feed water required by the system's boilers. Groundwater in the region exhibited moderate total suspended solids and high alkalinity and hardness levels, and the RO system required feed water with a silt density index of 3 or less. The conventional pretreatment system used at the site was slowing down production due to the severe fouling of the RO membranes. The new microfiltration system contained an automated PVDF hollow fiber microfiltration membrane system contained in a trailer. Suspended particles and bacteria were captured within the filter, and permeate was sent to the RO unit. Within 6 hours of being installed, the unit was producing water with SDI values in the range of 1.0 to 2.5. It was concluded that the microfiltration system performed reliably regardless of wide variations in feed water quality and flow rates. 3 refs., 1 tab., 8 figs.

  10. High-reliability, 4. pi. -scan, leakage-x-ray dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, T; Iida, H; Yoshida, T; Sugimoto, H [Tokyo Shibaura Electric Co. Ltd., Kawasaki, Kanagawa (Japan). Tamagawa Works

    1978-04-01

    A world-wide movement is growing for the protection of living bodies against leakage radiations. In Japan, detailed regulations have been established for the enforcement of the law in regard to this problem. The substances of the measurement provided in the regulations are extremely diversified, much affecting the reliability and the economic efficiency of the equipment. Now a new 4..pi..-scan X-ray dosimeter with high reliability has been developed and proved to effect qualitative improvement of measurement as well as elevation of productivity.

  11. Modeling high-Power Accelerators Reliability-SNS LINAC (SNS-ORNL); MAX LINAC (MYRRHA)

    International Nuclear Information System (INIS)

    Pitigoi, A. E.; Fernandez Ramos, P.

    2013-01-01

    Improving reliability has recently become a very important objective in the field of particle accelerators. The particle accelerators in operation are constantly undergoing modifications, and improvements are implemented using new technologies, more reliable components or redundant schemes (to obtain more reliability, strength, more power, etc.) A reliability model of SNS (Spallation Neutron Source) LINAC has been developed within MAX project and analysis of the accelerator systems reliability has been performed within the MAX project, using the Risk Spectrum reliability analysis software. The analysis results have been evaluated by comparison with the SNS operational data. Results and conclusions are presented in this paper, oriented to identify design weaknesses and provide recommendations for improving reliability of MYRRHA linear accelerator. The SNS reliability model developed for the MAX preliminary design phase indicates possible avenues for further investigation that could be needed to improve the reliability of the high-power accelerators, in view of the future reliability targets of ADS accelerators.

  12. Validity and Reliability of the Academic Resilience Scale in Turkish High School

    Science.gov (United States)

    Kapikiran, Sahin

    2012-01-01

    The present study aims to determine the validity and reliability of the academic resilience scale in Turkish high school. The participances of the study includes 378 high school students in total (192 female and 186 male). A set of analyses were conducted in order to determine the validity and reliability of the study. Firstly, both exploratory…

  13. Inter-rater and test-retest reliability of quality assessments by novice student raters using the Jadad and Newcastle-Ottawa Scales.

    Science.gov (United States)

    Oremus, Mark; Oremus, Carolina; Hall, Geoffrey B C; McKinnon, Margaret C

    2012-01-01

    Quality assessment of included studies is an important component of systematic reviews. The authors investigated inter-rater and test-retest reliability for quality assessments conducted by inexperienced student raters. Student raters received a training session on quality assessment using the Jadad Scale for randomised controlled trials and the Newcastle-Ottawa Scale (NOS) for observational studies. Raters were randomly assigned into five pairs and they each independently rated the quality of 13-20 articles. These articles were drawn from a pool of 78 papers examining cognitive impairment following electroconvulsive therapy to treat major depressive disorder. The articles were randomly distributed to the raters. Two months later, each rater re-assessed the quality of half of their assigned articles. McMaster Integrative Neuroscience Discovery and Study Program. 10 students taking McMaster Integrative Neuroscience Discovery and Study Program courses. The authors measured inter-rater reliability using κ and the intraclass correlation coefficient type 2,1 or ICC(2,1). The authors measured test-retest reliability using ICC(2,1). Inter-rater reliability varied by scale question. For the six-item Jadad Scale, question-specific κs ranged from 0.13 (95% CI -0.11 to 0.37) to 0.56 (95% CI 0.29 to 0.83). The ranges were -0.14 (95% CI -0.28 to 0.00) to 0.39 (95% CI -0.02 to 0.81) for the NOS cohort and -0.20 (95% CI -0.49 to 0.09) to 1.00 (95% CI 1.00 to 1.00) for the NOS case-control. For overall scores on the six-item Jadad Scale, ICC(2,1)s for inter-rater and test-retest reliability (accounting for systematic differences between raters) were 0.32 (95% CI 0.08 to 0.52) and 0.55 (95% CI 0.41 to 0.67), respectively. Corresponding ICC(2,1)s for the NOS cohort were -0.19 (95% CI -0.67 to 0.35) and 0.62 (95% CI 0.25 to 0.83), and for the NOS case-control, the ICC(2,1)s were 0.46 (95% CI -0.13 to 0.92) and 0.83 (95% CI 0.48 to 0.95). Inter-rater reliability was generally poor

  14. [Care quality: reliability and usefulness of observation data in bench marking nursing homes and homes for the aged in the Netherlands].

    Science.gov (United States)

    Frijters, Dinnus; Gerritsen, Debby; Steverink, Nardi

    2003-02-01

    Before including quality of care indicators in the Benchmark of Nursing Homes and Homes for the Aged in the Netherlands the reliability of the patient data collection, and usefulness had to be established. The patient data items were derived from the Resident Assessment Instruments (RAI) and a questionnaire on social interaction in elderly people. Three nursing homes and three homes for the aged participated in the test with 550 patients. 279 x 2 assessments were collected by independent raters for an inter rater reliability test; 259 x 2 by the same rater for a reliability test-retest; and 24 by a single rater. The scores on paired assessment forms were compared with the weighted Kappa agreement test. The test results allowed 10 of the 13 quality indicators from RAI to be retained. In addition new quality indicators could be defined on 'giving attention' and 'unrespectful addressing'. We estimate on the basis of a questionnaire for the raters that on average 9 to 12 minutes per patient are needed to collect and enter data for the resulting 12 quality indicators.

  15. Why do quality and reliability feedback loops not always work in practice: a case study

    Energy Technology Data Exchange (ETDEWEB)

    Molenaar, P.A.; Huijben, A.J.M.; Bouwhuis, D.; Brombacher, A.C

    2002-03-01

    The increasing competition in the market of consumer electronics forces industry to simultaneously improve the functionability, reliability and costs of their products. Due to the strong dynamics of this field an important measure in improving product quality is the feedback of information on actual field behaviour of a product which is extremely relevant for product development. This information, usually gathered by the service department, can help development to learn from the failures of earlier products and to improve the next product generations. This feedback process, however, does not always bring the expected benefits. This paper presents a model, based on an actual case study, of the structure of the feedback process in terms of information flows. The information flow model describes the chain or network of activities in the feedback process as a function of (different) drivers such as cost, time or quality. Using this information flow model it is possible to explain how quality and reliability related information propagates through a business process and where and why communication problems lead to disruptions in the feedback of this information. With this model, it is easier to understand the function of different parties in the service or after sales process, so that management of the information in this process becomes more transparent and can be improved.

  16. Why do quality and reliability feedback loops not always work in practice: a case study

    International Nuclear Information System (INIS)

    Molenaar, P.A.; Huijben, A.J.M.; Bouwhuis, D.; Brombacher, A.C.

    2002-01-01

    The increasing competition in the market of consumer electronics forces industry to simultaneously improve the functionability, reliability and costs of their products. Due to the strong dynamics of this field an important measure in improving product quality is the feedback of information on actual field behaviour of a product which is extremely relevant for product development. This information, usually gathered by the service department, can help development to learn from the failures of earlier products and to improve the next product generations. This feedback process, however, does not always bring the expected benefits. This paper presents a model, based on an actual case study, of the structure of the feedback process in terms of information flows. The information flow model describes the chain or network of activities in the feedback process as a function of (different) drivers such as cost, time or quality. Using this information flow model it is possible to explain how quality and reliability related information propagates through a business process and where and why communication problems lead to disruptions in the feedback of this information. With this model, it is easier to understand the function of different parties in the service or after sales process, so that management of the information in this process becomes more transparent and can be improved

  17. A roadmap to high quality chemically prepared graphene

    Energy Technology Data Exchange (ETDEWEB)

    Gengler, Regis Y N; Spyrou, Konstantinos; Rudolf, Petra, E-mail: r.gengler@rug.n, E-mail: p.rudolf@rug.n [Zernike Institute for Advanced Materials, University of Groningen, Nijenborgh 4, 9747AG Groningen (Netherlands)

    2010-09-22

    Graphene was discovered half a decade ago and proved the existence of a two-dimensional system which becomes stable as a result of 3D corrugation. It appeared very quickly that this exceptional material had truly outstanding electronic, mechanical, thermal and optical properties. Consequently a broad range of applications appeared, as the graphene science speedily moved forward. Since then, a lot of effort has been devoted not only to the study of graphene but also to its fabrication. Here we review the chemical approaches to graphene production, their advantages as well as their downsides. Our aim is to draw a roadmap of today's most reliable path to high quality graphene via chemical preparation.

  18. A roadmap to high quality chemically prepared graphene

    International Nuclear Information System (INIS)

    Gengler, Regis Y N; Spyrou, Konstantinos; Rudolf, Petra

    2010-01-01

    Graphene was discovered half a decade ago and proved the existence of a two-dimensional system which becomes stable as a result of 3D corrugation. It appeared very quickly that this exceptional material had truly outstanding electronic, mechanical, thermal and optical properties. Consequently a broad range of applications appeared, as the graphene science speedily moved forward. Since then, a lot of effort has been devoted not only to the study of graphene but also to its fabrication. Here we review the chemical approaches to graphene production, their advantages as well as their downsides. Our aim is to draw a roadmap of today's most reliable path to high quality graphene via chemical preparation.

  19. Survey of industry methods for producing highly reliable software

    International Nuclear Information System (INIS)

    Lawrence, J.D.; Persons, W.L.

    1994-11-01

    The Nuclear Reactor Regulation Office of the US Nuclear Regulatory Commission is charged with assessing the safety of new instrument and control designs for nuclear power plants which may use computer-based reactor protection systems. Lawrence Livermore National Laboratory has evaluated the latest techniques in software reliability for measurement, estimation, error detection, and prediction that can be used during the software life cycle as a means of risk assessment for reactor protection systems. One aspect of this task has been a survey of the software industry to collect information to help identify the design factors used to improve the reliability and safety of software. The intent was to discover what practices really work in industry and what design factors are used by industry to achieve highly reliable software. The results of the survey are documented in this report. Three companies participated in the survey: Computer Sciences Corporation, International Business Machines (Federal Systems Company), and TRW. Discussions were also held with NASA Software Engineering Lab/University of Maryland/CSC, and the AIAA Software Reliability Project

  20. Reliability of the Quality of Upper Extremity Skills Test for Children with Cerebral Palsy Aged 2 to 12 Years

    Science.gov (United States)

    Thorley, Megan; Lannin, Natasha; Cusick, Anne; Novak, Iona; Boyd, Roslyn

    2012-01-01

    Aim: To investigate reliability of the Quality of Upper Extremity Skills Test (QUEST) scores for children with cerebral palsy (CP) aged 2-12 years. Method: Thirty-one QUESTs from 24 children with CP were rated once by two raters and twice by one rater. Internal consistency of total scores, inter- and intra-rater reliability findings for total,…

  1. Engineering high reliability, low-jitter Marx generators

    International Nuclear Information System (INIS)

    Schneider, L.X.; Lockwood, G.J.

    1985-01-01

    Multimodule pulsed power accelerators typically require high module reliability and nanosecond regime simultaneity between modules. Energy storage using bipolar Marx generators can meet these requirements. Experience gained from computer simulations and the development of the DEMON II Marx generator has led to a fundamental understanding of the operation of these multistage devices. As a result of this research, significant improvements in erection time jitter and reliability have been realized in multistage, bipolar Marx generators. Erection time jitter has been measured as low as 2.5 nanoseconds for the 3.2MV, 16-stage PBFA I Marx and 3.5 nanoseconds for the 6.0MV, 30-stage PBFA II (DEMON II) Marx, while maintaining exceptionally low prefire rates. Performance data are presented from the DEMON II Marx research program, as well as discussions on the use of computer simulations in designing low-jitter Marx generators

  2. Watershed reliability, resilience and vulnerability analysis under uncertainty using water quality data.

    Science.gov (United States)

    Hoque, Yamen M; Tripathi, Shivam; Hantush, Mohamed M; Govindaraju, Rao S

    2012-10-30

    A method for assessment of watershed health is developed by employing measures of reliability, resilience and vulnerability (R-R-V) using stream water quality data. Observed water quality data are usually sparse, so that a water quality time-series is often reconstructed using surrogate variables (streamflow). A Bayesian algorithm based on relevance vector machine (RVM) was employed to quantify the error in the reconstructed series, and a probabilistic assessment of watershed status was conducted based on established thresholds for various constituents. As an application example, observed water quality data for several constituents at different monitoring points within the Cedar Creek watershed in north-east Indiana (USA) were utilized. Considering uncertainty in the data for the period 2002-2007, the R-R-V analysis revealed that the Cedar Creek watershed tends to be in compliance with respect to selected pesticides, ammonia and total phosphorus. However, the watershed was found to be prone to violations of sediment standards. Ignoring uncertainty in the water quality time-series led to misleading results especially in the case of sediments. Results indicate that the methods presented in this study may be used for assessing the effects of different stressors over a watershed. The method shows promise as a management tool for assessing watershed health. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Validity and Reliability of Accelerometers in Patients With COPD: A SYSTEMATIC REVIEW.

    Science.gov (United States)

    Gore, Shweta; Blackwood, Jennifer; Guyette, Mary; Alsalaheen, Bara

    2018-05-01

    Reduced physical activity is associated with poor prognosis in chronic obstructive pulmonary disease (COPD). Accelerometers have greatly improved quantification of physical activity by providing information on step counts, body positions, energy expenditure, and magnitude of force. The purpose of this systematic review was to compare the validity and reliability of accelerometers used in patients with COPD. An electronic database search of MEDLINE and CINAHL was performed. Study quality was assessed with the Strengthening the Reporting of Observational Studies in Epidemiology checklist while methodological quality was assessed using the modified Quality Appraisal Tool for Reliability Studies. The search yielded 5392 studies; 25 met inclusion criteria. The SenseWear Pro armband reported high criterion validity under controlled conditions (r = 0.75-0.93) and high reliability (ICC = 0.84-0.86) for step counts. The DynaPort MiniMod demonstrated highest concurrent validity for step count using both video and manual methods. Validity of the SenseWear Pro armband varied between studies especially in free-living conditions, slower walking speeds, and with addition of weights during gait. A high degree of variability was found in the outcomes used and statistical analyses performed between studies, indicating a need for further studies to measure reliability and validity of accelerometers in COPD. The SenseWear Pro armband is the most commonly used accelerometer in COPD, but measurement properties are limited by gait speed variability and assistive device use. DynaPort MiniMod and Stepwatch accelerometers demonstrated high validity in patients with COPD but lack reliability data.

  4. Instrument reliability for high-level nuclear-waste-repository applications

    International Nuclear Information System (INIS)

    Rogue, F.; Binnall, E.P.; Armantrout, G.A.

    1983-01-01

    Reliable instrumentation will be needed to evaluate the characteristics of proposed high-level nuclear-wasted-repository sites and to monitor the performance of selected sites during the operational period and into repository closure. A study has been done to assess the reliability of instruments used in Department of Energy (DOE) waste repository related experiments and in other similar geological applications. The study included experiences with geotechnical, hydrological, geochemical, environmental, and radiological instrumentation and associated data acquisition equipment. Though this paper includes some findings on the reliability of instruments in each of these categories, the emphasis is on experiences with geotechnical instrumentation in hostile repository-type environments. We review the failure modes, rates, and mechanisms, along with manufacturers modifications and design changes to enhance and improve instrument performance; and include recommendations on areas where further improvements are needed

  5. Aerospace reliability applied to biomedicine.

    Science.gov (United States)

    Lalli, V. R.; Vargo, D. J.

    1972-01-01

    An analysis is presented that indicates that the reliability and quality assurance methodology selected by NASA to minimize failures in aerospace equipment can be applied directly to biomedical devices to improve hospital equipment reliability. The Space Electric Rocket Test project is used as an example of NASA application of reliability and quality assurance (R&QA) methods. By analogy a comparison is made to show how these same methods can be used in the development of transducers, instrumentation, and complex systems for use in medicine.

  6. Quality of Life among Persons with HIV/AIDS in Iran: Internal Reliability and Validity of an International Instrument and Associated Factors

    Directory of Open Access Journals (Sweden)

    Pedram Razavi

    2012-01-01

    Full Text Available The purpose of this cross-sectional study on 191 HIV/AIDS patient was to prepare the first Persian translation of complete WHOQOL-HIV instrument, evaluate its reliability and validity, and apply it to determine quality of life and its associated factors in Tehran, Iran. Student's t-test was used to compare quality of life between groups. Mean Cronbach’s α of facets in all six domains of instrument were more than 0.6 indicating good reliability. Item/total corrected correlations coefficients had a lower limit of more than 0.5 in all facets except for association between energy and fatigue facet and physical domain. Compared to younger participants, patients older than 35 years had significantly lower scores in overall quality of life (P = 0.003, social relationships (P = 0.021, and spirituality/religion/personal beliefs (P = 0.024. Unemployed patients had significantly lower scores in overall quality of life (P = 0.01, level of independence (P = 0.004, and environment (P = 0.001 compared to employed participants. This study demonstrated that the standard, complete WHOQOL-HIV 120 instrument translated into Farsi and evaluated among Iranian participants provides a reliable and valid basis for future research on quality of life for HIV and other patients in Iran.

  7. Construct Validity and Reliability of the Questionnaire on the Quality of Physician-Patient Interaction in Adults With Hypertension.

    Science.gov (United States)

    Hickman, Ronald L; Clochesy, John M; Hetland, Breanna; Alaamri, Marym

    2017-04-01

    There are limited reliable and valid measures of the patient- provider interaction among adults with hypertension. Therefore, the purpose of this report is to describe the construct validity and reliability of the Questionnaire on the Quality of Physician-Patient Interaction (QQPPI), in community-dwelling adults with hypertension. A convenience sample of 109 participants with hypertension was recruited and administered the QQPPI at baseline and 8 weeks later. The exploratory factor analysis established a 12-item, 2-factor structure for the QQPPI was valid in this sample. The modified QQPPI proved to have sufficient internal consistency and test- retest reliability. The modified QQPPI is a valid and reliable measure of the provider-patient interaction, a construct posited to impact self-management, in adults with hypertension.

  8. Validity and reliability of the Iranian version of the Pediatric Quality of Life Inventory™ 4.0 (PedsQL™ Generic Core Scales in children

    Directory of Open Access Journals (Sweden)

    Amiri Parisa

    2012-01-01

    Full Text Available Abstract Background This study aimed to investigate the reliability and validity of the Iranian version of the Pediatric Quality of Life Inventory™ 4.0 (PedsQL™ 4.0 Generic Core Scales in children. Methods A standard forward and backward translation procedure was used to translate the US English version of the PedsQL™ 4.0 Generic Core Scales for children into the Iranian language (Persian. The Iranian version of the PedsQL™ 4.0 Generic Core Scales was completed by 503 healthy and 22 chronically ill children aged 8-12 years and their parents. The reliability was evaluated using internal consistency. Known-groups discriminant comparisons were made, and exploratory factor analysis (EFA and confirmatory factor analysis (CFA were conducted. Results The internal consistency, as measured by Cronbach's alpha coefficients, exceeded the minimum reliability standard of 0.70. All monotrait-multimethod correlations were higher than multitrait-multimethod correlations. The intraclass correlation coefficients (ICC between the children self-report and parent proxy-reports showed moderate to high agreement. Exploratory factor analysis extracted six factors from the PedsQL™ 4.0 for both self and proxy reports, accounting for 47.9% and 54.8% of total variance, respectively. The results of the confirmatory factor analysis for 6-factor models for both self-report and proxy-report indicated acceptable fit for the proposed models. Regarding health status, as hypothesized from previous studies, healthy children reported significantly higher health-related quality of life than those with chronic illnesses. Conclusions The findings support the initial reliability and validity of the Iranian version of the PedsQL™ 4.0 as a generic instrument to measure health-related quality of life of children in Iran.

  9. The role of high cycle fatigue (HCF) onset in Francis runner reliability

    International Nuclear Information System (INIS)

    Gagnon, M; Tahan, S A; Bocher, P; Thibault, D

    2012-01-01

    High Cycle Fatigue (HCF) plays an important role in Francis runner reliability. This paper presents a model in which reliability is defined as the probability of not exceeding a threshold above which HCF contributes to crack propagation. In the context of combined Low Cycle Fatigue (LCF) and HCF loading, the Kitagawa diagram is used as the limit state threshold for reliability. The reliability problem is solved using First-Order Reliability Methods (FORM). A study case is proposed using in situ measured strains and operational data. All the parameters of the reliability problem are based either on observed data or on typical design specifications. From the results obtained, we observed that the uncertainty around the defect size and the HCF stress range play an important role in reliability. At the same time, we observed that expected values for the LCF stress range and the number of LCF cycles have a significant influence on life assessment, but the uncertainty around these values could be neglected in the reliability assessment.

  10. An experimental study of assessment of weld quality on fatigue reliability analysis of a nuclear pressure vessel

    International Nuclear Information System (INIS)

    Dai Shuhe

    1993-01-01

    The steam generator in PWR primary coolant system China of Qinshan Nuclear Power Plant is a crucial unit belonging to the category of nuclear pressure vessel. The purpose of this research work is to make an examination of the weld quality of the steam generator under fatigue loading and to assess its reliability by using the experimental results of fatigue test of material of nuclear pressure vessel S-271 (Chinese Standard) and of qualified tests of welded seams of a simulated prototype of bottom closure head of the steam generator. A guarantee of weld quality is proposed as a subsequent verification for China National Nuclear Safety Supervision Bureau. The results of reliability analysis reported in this work can be taken as a supplementary material of Probabilistic Safety Assessment (PSA) of Qinshan Nuclear Power Plant. According to the requirement of Provision II-1500 cyclic testing, ASME Boiler and Pressure Vessel Code, Section III, Rules for Construction of Nuclear Power Plant Components, a simulated prototype of the bottom closure head of the steam generator was made for qualified tests. To find the quantified results of reliability assessment by using the testing data, two proposals are presented

  11. Efficiency criteria for high reliability measured system structures

    International Nuclear Information System (INIS)

    Sal'nikov, N.L.

    2012-01-01

    The procedures of structural redundancy are usually used to develop high reliability measured systems. To estimate efficiency of such structures the criteria to compare different systems has been developed. So it is possible to develop more exact system by inspection of redundant system data unit stochastic characteristics in accordance with the developed criteria [ru

  12. Designing reliability into high-effectiveness industrial gas turbine regenerators

    International Nuclear Information System (INIS)

    Valentino, S.J.

    1979-01-01

    The paper addresses the measures necessary to achieve a reliable regenerator design that can withstand higher temperatures (1000-1200 F) and many start and stop cycles - conditions encountered in high-efficiency operation in pipeline applications. The discussion is limited to three major areas: (1) structural analysis of the heat exchanger core - the part of the regenerator that must withstand the higher temperatures and cyclic duty (2) materials data and material selection and (3) a comprehensive test program to demonstrate the reliability of the regenerator. This program includes life-cycle tests, pressure containment in fin panels, core-to-core joint structural test, bellows pressure containment test, sliding pad test, core gas-side passage flow distribution test, and production test. Today's regenerators must have high cyclic life capability, stainless steel construction, and long fault-free service life of 120,000 hr

  13. Reliability and Validity of the Turkish Version of the Voice-Related Quality of Life Measure.

    Science.gov (United States)

    Tezcaner, Zahide Çiler; Aksoy, Songül

    2017-03-01

    This study aims to test the validity and reliability of the Turkish version of the Voice-Related Quality of Life (V-RQOL) questionnaire. This is a nonrandomized, prospective study with control group. The questionnaire was administered to 249 individuals-130 with vocal complaint and 119 without-with a mean age of 37.8 ± 12.3 years. The Turkish version of the Voice Handicap Index (VHI) and perceptual voice evaluation measures were also administered at 2-14 days for retest reliability. The instrument was submitted to validity and reliability evaluation. The V-RQOL measure showed a strong internal consistency and test-retest reliability; the Cronbach's alpha coefficient for the overall V-RQOL was 0.969, the physical functioning domain was 0.949, and the social-emotional domain was 0.940. In the test-retest reliability test, the overall V-RQOL was found to be 0.989. The construct validity of the V-RQOL was determined based on the strength and direction of its relation to the VHI and the perceptual voice evaluation measure. The higher the VHI level, the lower the physical functioning, social-emotional, and overall score levels of the V-RQOL (r = -0.927, r = -0.912, r = -0.944, respectively; P reliability and validity and may play a crucial role in evaluating Turkish-speaking patients with voice disorders. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  14. Inter-rater and test–retest reliability of quality assessments by novice student raters using the Jadad and Newcastle–Ottawa Scales

    Science.gov (United States)

    Oremus, Carolina; Hall, Geoffrey B C; McKinnon, Margaret C

    2012-01-01

    Introduction Quality assessment of included studies is an important component of systematic reviews. Objective The authors investigated inter-rater and test–retest reliability for quality assessments conducted by inexperienced student raters. Design Student raters received a training session on quality assessment using the Jadad Scale for randomised controlled trials and the Newcastle–Ottawa Scale (NOS) for observational studies. Raters were randomly assigned into five pairs and they each independently rated the quality of 13–20 articles. These articles were drawn from a pool of 78 papers examining cognitive impairment following electroconvulsive therapy to treat major depressive disorder. The articles were randomly distributed to the raters. Two months later, each rater re-assessed the quality of half of their assigned articles. Setting McMaster Integrative Neuroscience Discovery and Study Program. Participants 10 students taking McMaster Integrative Neuroscience Discovery and Study Program courses. Main outcome measures The authors measured inter-rater reliability using κ and the intraclass correlation coefficient type 2,1 or ICC(2,1). The authors measured test–retest reliability using ICC(2,1). Results Inter-rater reliability varied by scale question. For the six-item Jadad Scale, question-specific κs ranged from 0.13 (95% CI −0.11 to 0.37) to 0.56 (95% CI 0.29 to 0.83). The ranges were −0.14 (95% CI −0.28 to 0.00) to 0.39 (95% CI −0.02 to 0.81) for the NOS cohort and −0.20 (95% CI −0.49 to 0.09) to 1.00 (95% CI 1.00 to 1.00) for the NOS case–control. For overall scores on the six-item Jadad Scale, ICC(2,1)s for inter-rater and test–retest reliability (accounting for systematic differences between raters) were 0.32 (95% CI 0.08 to 0.52) and 0.55 (95% CI 0.41 to 0.67), respectively. Corresponding ICC(2,1)s for the NOS cohort were −0.19 (95% CI −0.67 to 0.35) and 0.62 (95% CI 0.25 to 0.83), and for the NOS case–control, the ICC(2

  15. Evaluations of methods for the isolation of high quality RNA from bovine and cervine hide biopsies for use in gene expression studies

    Science.gov (United States)

    Molecular investigations of the ruminant response to ectoparasites at the parasite-host interface are critically dependent upon the quality of RNA. The complexity of ruminant skin decreases the capacity to obtain high quality RNA from biopsy samples, which directly affects the reliability of data pr...

  16. Quality of life in oncological patients with oropharyngeal dysphagia: validity and reliability of the Dutch version of the MD Anderson Dysphagia Inventory and the Deglutition Handicap Index.

    Science.gov (United States)

    Speyer, Renée; Heijnen, Bas J; Baijens, Laura W; Vrijenhoef, Femke H; Otters, Elsemieke F; Roodenburg, Nel; Bogaardt, Hans C

    2011-12-01

    Quality of life is an important outcome measurement in objectifying the current health status or therapy effects in patients with oropharyngeal dysphagia. In this study, the validity and reliability of the Dutch version of the Deglutition Handicap Index (DHI) and the MD Anderson Dysphagia Inventory (MDADI) have been determined for oncological patients with oropharyngeal dysphagia. At Maastricht University Medical Center, 76 consecutive patients were selected and asked to fill in three questionnaires on quality of life related to oropharyngeal dysphagia (the SWAL-QOL, the MDADI, and the DHI) as well as a simple one-item visual analog Dysphagia Severity Scale. None of the quality-of-life questionnaires showed any floor or ceiling effect. The test-retest reliability of the MDADI and the Dysphagia Severity Scale proved to be good. The test-retest reliability of the DHI could not be determined because of insufficient data, but the intraclass correlation coefficients were rather high. The internal consistency proved to be good. However, confirmatory factor analysis could not distinguish the underlying constructs as defined by the subscales per questionnaire. When assessing criterion validity, both the MDADI and the DHI showed satisfactory associations with the SWAL-QOL (reference or gold standard) after having removed the less relevant subscales of the SWAL-QOL. In conclusion, when assessing the validity and reliability of the Dutch version of the DHI or the MDADI, not all psychometric properties have been adequately met. In general, because of difficulties in the interpretation of study results when using questionnaires lacking sufficient psychometric quality, it is recommended that researchers strive to use questionnaires with the most optimal psychometric properties.

  17. The validity and reliability of Systemic Lupus Erythematosus Quality of Life Questionnaire (L-QoL) in a Turkish population.

    Science.gov (United States)

    Duruöz, M T; Unal, C; Toprak, C Sanal; Sezer, I; Yilmaz, F; Ulutatar, F; Atagündüz, P; Baklacioglu, H S

    2017-12-01

    Background Systemic lupus erythematosus (SLE) may have a profound impact on quality of life. There is increasing interest in measuring quality of life in lupus patients. The purpose of this study was to investigate the validity and reliability of SLE Quality of Life Questionnaire (L-QoL) in Turkish SLE patients. Methods SLE according to 2012 Systemic Lupus International Collaborating Clinics Classification Criteria were recruited into the study. Demographic data, clinical parameters and disease activity measured with the Systemic Lupus Erythematosus Disease Activity Index-2000 (SLEDAI-2K); were noted. Nottingham Health Profile and Health Assessment Questionnaire were filled out in addition to the Turkish L-QoL (LQoL-TR). Internal consistency, test-retest reliability, and convergent and discriminant validity were evaluated. Results The mean age of participants was 43.55 ± 14.33 years and the mean disease duration was 89.8 ± 92.1 months. The patients filled out LQoL-TR in 2.5 min. Strong correlation of LQoL-TR with all subgroups of the Nottingham Health Profile and the Health Assessment Questionnaire were established showing the convergent validity. The highest correlation was demonstrated with emotional reactions (rho = 0.72) and sleep component (rho = 0.65) of the Nottingham Health Profile scale ( p < 0.0001). Its poor and not significant correlation with nonfunctional parameters (age, disease duration, perceived general health, SLEDAI-2K) showed its discriminative properties. LQoL-TR demonstrated good internal reliability with a Cronbach's α of 0.93 and test-retest reliability with intraclass correlation coefficient of 0.87. Conclusion The LQoL-TR is a practical and useful tool which demonstrates good validity and reliability.

  18. Fracture Toughness and Reliability in High-Temperature Structural Ceramics and Composites: Prospects and Challenges for the 21st Century

    Science.gov (United States)

    Dutta, Sunil

    1999-01-01

    The importance of high fracture toughness and reliability in Si3N4, and SiC-based structural ceramics and ceramic matrix composites is reviewed. The potential of these ceramics and ceramic matrix composites for high temperature applications in defense and aerospace applications such as gas turbine engines, radomes, and other energy conversion hardware have been well recognized. Numerous investigations were pursued to improve fracture toughness and reliability by incorporating various reinforcements such as particulate-, whisker-, and continuous fiber into Si3N4 and SiC matrices. All toughening mechanisms, e.g. crack deflection, crack branching, crack bridging, etc., essentially redistribute stresses at the crack tip and increase the energy needed to propagate a crack through the composite material, thereby resulting in improved fracture toughness and reliability. Because of flaw insensitivity, continuous fiber reinforced ceramic composite (CFCC) was found to have the highest potential for higher operating temperature and longer service conditions. However, the ceramic fibers should display sufficient high temperature strength and creep resistance at service temperatures above 1000 'C. The greatest challenge to date is the development of high quality ceramic fibers with associate coatings able to maintain their high strength in oxidizing environment at high temperature. In the area of processing, critical issues are, preparation of optimum matrix precursors, precursor infiltration into fiber array, and matrix densification at a temperature, where grain crystallization and fiber degradation do not occur. A broad scope of effort is required for improved processing and properties with a better understanding of all candidate composite systems.

  19. The reliability of the Glasgow Coma Scale: a systematic review.

    Science.gov (United States)

    Reith, Florence C M; Van den Brande, Ruben; Synnot, Anneliese; Gruen, Russell; Maas, Andrew I R

    2016-01-01

    The Glasgow Coma Scale (GCS) provides a structured method for assessment of the level of consciousness. Its derived sum score is applied in research and adopted in intensive care unit scoring systems. Controversy exists on the reliability of the GCS. The aim of this systematic review was to summarize evidence on the reliability of the GCS. A literature search was undertaken in MEDLINE, EMBASE and CINAHL. Observational studies that assessed the reliability of the GCS, expressed by a statistical measure, were included. Methodological quality was evaluated with the consensus-based standards for the selection of health measurement instruments checklist and its influence on results considered. Reliability estimates were synthesized narratively. We identified 52 relevant studies that showed significant heterogeneity in the type of reliability estimates used, patients studied, setting and characteristics of observers. Methodological quality was good (n = 7), fair (n = 18) or poor (n = 27). In good quality studies, kappa values were ≥0.6 in 85%, and all intraclass correlation coefficients indicated excellent reliability. Poor quality studies showed lower reliability estimates. Reliability for the GCS components was higher than for the sum score. Factors that may influence reliability include education and training, the level of consciousness and type of stimuli used. Only 13% of studies were of good quality and inconsistency in reported reliability estimates was found. Although the reliability was adequate in good quality studies, further improvement is desirable. From a methodological perspective, the quality of reliability studies needs to be improved. From a clinical perspective, a renewed focus on training/education and standardization of assessment is required.

  20. Systems reliability in high risk situations

    International Nuclear Information System (INIS)

    Hunns, D.M.

    1974-12-01

    A summary is given of five papers and the discussion of a seminar promoted by the newly-formed National Centre of Systems Reliability. The topics covered include hazard analysis, reliability assessment, and risk assessment in both nuclear and non-nuclear industries. (U.K.)

  1. The Effect of Anchors and Training on the Reliability of Voice Quality Ratings for Different Types of Speech Stimuli.

    Science.gov (United States)

    Brinca, Lilia; Batista, Ana Paula; Tavares, Ana Inês; Pinto, Patrícia N; Araújo, Lara

    2015-11-01

    The main objective of the present study was to investigate if the type of voice stimuli-sustained vowel, oral reading, and connected speech-results in good intrarater and interrater agreement/reliability. A short-term panel study was performed. Voice samples from 30 native European Portuguese speakers were used in the present study. The speech materials used were (1) the sustained vowel /a/, (2) oral reading of the European Portuguese version of "The Story of Arthur the Rat," and (3) connected speech. After an extensive training with textual and auditory anchors, the judges were asked to rate the severity of dysphonic voice stimuli using the phonation dimensions G, R, and B from the GRBAS scale. The voice samples were judged 6 months and 1 year after the training. Intrarater agreement and reliability were generally very good for all the phonation dimensions and voice stimuli. The highest interrater reliability was obtained using the oral reading stimulus, particularly for phonation dimensions grade (G) and breathiness (B). Roughness (R) was the voice quality that was the most difficult to evaluate, leading to interrater unreliability in all voice quality ratings. Extensive training using textual and auditory anchors and the use of anchors during the voice evaluations appear to be good methods for auditory-perceptual evaluation of dysphonic voices. The best results of interrater reliability were obtained when the oral reading stimulus was used. Breathiness appears to be a voice quality that is easier to evaluate than roughness. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  2. Impact of High-Reliability Education on Adverse Event Reporting by Registered Nurses.

    Science.gov (United States)

    McFarland, Diane M; Doucette, Jeffrey N

    Adverse event reporting is one strategy to identify risks and improve patient safety, but, historically, adverse events are underreported by registered nurses (RNs) because of fear of retribution and blame. A program was provided on high reliability to examine whether education would impact RNs' willingness to report adverse events. Although the findings were not statistically significant, they demonstrated a positive impact on adverse event reporting and support the need to create a culture of high reliability.

  3. Gearbox Reliability Collaborative High-Speed Shaft Calibration

    Energy Technology Data Exchange (ETDEWEB)

    Keller, J.; McNiff, B.

    2014-09-01

    Instrumentation has been added to the high-speed shaft, pinion, and tapered roller bearing pair of the Gearbox Reliability Collaborative gearbox to measure loads and temperatures. The new shaft bending moment and torque instrumentation was calibrated and the purpose of this document is to describe this calibration process and results, such that the raw shaft bending and torque signals can be converted to the proper engineering units and coordinate system reference for comparison to design loads and simulation model predictions.

  4. Learning Organizations in High Reliability Industries

    International Nuclear Information System (INIS)

    Schwalbe, D.; Wächter, C.

    2016-01-01

    Full text: Humans make mistakes. Sometimes we learn from them. In a high reliability organization we have to learn before an error leads to an incident (or even accident). Therefore the “human factor” is most important as most of the time the human is the last line of defense. The “human factor” is more than communication or leadership skills. At the end, it is the personal attitude. This attitude has to be safety minded. And this attitude has to be self-reflected continuously. Moreover, feedback from others is urgently needed to improve one’s personal skills daily and learn from our own experience as well as from others. (author

  5. Reliability and acceptability of the Multiple Sclerosis Quality of Life-29 questionnaire in an English-speaking cohort.

    Science.gov (United States)

    Baker, Georgina; Nair, Krishnan Padmakumari Sivaraman; Baster, Kathleen; Rosato, Rosalba; Solari, Alessandra

    2018-05-01

    Multiple Sclerosis Quality-of-Life Questionnaire-54 (MSQoL-54) is a disease-specific instrument for assessing health-related quality of life (HRQoL). Due to the number of items, the time taken to complete it is long. A shorter 29-item version, Multiple Sclerosis Quality-of-Life Questionnaire-29 (MSQoL-29) is yet to be evaluated in English. To assess reliability and acceptability of English version of MSQoL-29. Among 100 participants with MS who first completed both MSQoL-54 and MSQoL-29, 91 completed MSQoL-29 after 4-8 weeks. We looked for internal consistency (Cronbach's alpha), acceptability, reliability (intraclass correlation coefficients (ICCs)) and agreement (Bland-Altman plots). ICCs were strongly positive between MSQoL-54 and MSQoL-29 (Physical Health Composite (PHC) -ICC = 0.914, confidence interval (CI) = 0.872-0.942; Mental Health Composite (MHC) - ICC = 0.875, CI = 0.814-0.916) and between the two MSQoL-29 (PHC - ICC = 0.970, CI = 0.955-0.980; MHC - ICC = 0.937, CI = 0.904-0.958). On Bland-Altman plots, the MSQoL-29 scores of 95% of participants during two visits were within the limits of agreement (LOAs). Time taken to complete MSQoL-29 was 7.2 ± 2.9 minutes and MSQoL-54 was 19.79 ± 5.4 minutes ( p = 0.0001). MSQoL-29 has good test-retest reliability in English-speaking population and was quicker to complete.

  6. Ovarian stimulation and embryo quality

    NARCIS (Netherlands)

    Baart, Esther; Macklon, Nick S.; Fauser, Bart J. C. M.

    To Study the effects of different ovarian stimulation approaches on oocyte and embryo quality, it is imperative to assess embryo quality with a reliable and objective method. Embryos rated as high quality by standardized morphological assessment are associated with higher implantation and pregnancy

  7. Reliability of physical examination tests for the diagnosis of knee disorders: Evidence from a systematic review.

    Science.gov (United States)

    Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Desmeules, François

    2016-12-01

    Clinicians often rely on physical examination tests to guide them in the diagnostic process of knee disorders. However, reliability of these tests is often overlooked and may influence the consistency of results and overall diagnostic validity. Therefore, the objective of this study was to systematically review evidence on the reliability of physical examination tests for the diagnosis of knee disorders. A structured literature search was conducted in databases up to January 2016. Included studies needed to report reliability measures of at least one physical test for any knee disorder. Methodological quality was evaluated using the QAREL checklist. A qualitative synthesis of the evidence was performed. Thirty-three studies were included with a mean QAREL score of 5.5 ± 0.5. Based on low to moderate quality evidence, the Thessaly test for meniscal injuries reached moderate inter-rater reliability (k = 0.54). Based on moderate to excellent quality evidence, the Lachman for anterior cruciate ligament injuries reached moderate to excellent inter-rater reliability (k = 0.42 to 0.81). Based on low to moderate quality evidence, the Tibiofemoral Crepitus, Joint Line and Patellofemoral Pain/Tenderness, Bony Enlargement and Joint Pain on Movement tests for knee osteoarthritis reached fair to excellent inter-rater reliability (k = 0.29 to 0.93). Based on low to moderate quality evidence, the Lateral Glide, Lateral Tilt, Lateral Pull and Quality of Movement tests for patellofemoral pain reached moderate to good inter-rater reliability (k = 0.49 to 0.73). Many physical tests appear to reach good inter-rater reliability, but this is based on low-quality and conflicting evidence. High-quality research is required to evaluate the reliability of knee physical examination tests. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. The high-precision x-ray tomograph for quality control of the ATLAS MDT muon spectrometer

    CERN Document Server

    Drakoulakos, D G; Maugain, J M; Rohrbach, F; Sedykh, Yu

    1997-01-01

    For the Large Hadron Collider (LHC) of the next millennium, a large general-purpose high-energy physics experiment, the ATLAS project, is being designed by a world-wide collaboration. One of its detectors, the ATLAS muon tracking detector, the MDT project, is on the scale of a very large industrial project: the design, the construction and assembly of twelve hundred large muon drift chambers are aimed at producing an exceptional quality in terms of accuracy, material reliability, assembly, and monitoring. This detector, based on the concept of very high mechanical precision required by the physics goals, will use tomography as a quality control platform. An X-ray tomograph prototype, monitored by a set of interferometers, has been developed at CERN to provide high-quality control of the MDT chambers which will be built in the collaborating institutes of the ATLAS project. First results have been obtained on MDT prototypes showing the validity of the X-ray tomograph approach for mechanical control of the detec...

  9. Educational Management Organizations as High Reliability Organizations: A Study of Victory's Philadelphia High School Reform Work

    Science.gov (United States)

    Thomas, David E.

    2013-01-01

    This executive position paper proposes recommendations for designing reform models between public and private sectors dedicated to improving school reform work in low performing urban high schools. It reviews scholarly research about for-profit educational management organizations, high reliability organizations, American high school reform, and…

  10. Electricity supply. Older plants' impact on reliability and air quality

    International Nuclear Information System (INIS)

    England-Joseph, Judy A.; Adams, Charles M.; Wood, David G.; Feehan, Daniel J.; Veal, Howard F.; Skeen, John H. III; Koenigs, Melvin J.; Lichtenfeld, David I.; Seretakis, Pauline J.

    1990-09-01

    Life extension of fossil fuel plants is a relatively recent phenomenon; thus, utilities have little experience to demonstrate the longer-term operating reliability of plants with an extended service life. While utility industry officials and government and industry studies express optimism that these plants will continue to operate reliably, the officials and the studies also caution that it is too soon to determine how pursuing life extension will affect the reliability of the nation's electricity supply. According to DOE, the number of fossil fuel generating units' 30 years old or older is expected to increase from about 2,500 in 1989 to roughly 3,700 in 1998, increasing such plants' share of overall generating capacity from 13 percent in 1989 to 27 percent in 1998. EPA estimates that with existing air quality requirements, fossil fuel plant emissions will increase steadily during the coming decade. Proposed acid rain control legislation, which would affect many plants that may have their service life extended, would require utilities to significantly reduce emissions by the year 2000 but would allow utilities flexibility in deciding how and where to achieve the reductions. If such legislation is enacted, utilities generally are expected to find reducing emissions from existing plants more cost-effective than replacing them and to continue extending plants' service life. Officials of DOE and utility organizations expressed concern, however, that EPA could decide, as it did for one plant in 1988, that alterations made in extending the service life of plants exempted from the Clean Air Act would result in increased emissions and thus cause the altered plants to lose their exemption. According to the officials, the additional costs of achieving the Clean Air Act's standards could discourage some life extension projects. However, such decisions by EPA could also reduce the nation's total power plant emissions by eliminating an existing incentive to retain exempt

  11. Intra- and inter-rater reliability of movement and palpation tests in patients with neck pain: A systematic review.

    Science.gov (United States)

    Jonsson, Anders; Rasmussen-Barr, Eva

    2018-03-01

    Neck pain is common and often becomes chronic. Various clinical tests of the cervical spine are used to direct and evaluate treatment. This systematic review aimed to identify studies examining the intra- and/or interrater reliability of tests used in clinical examination of patients with neck pain. A database search up to April 2016 was conducted in PubMed, CINAHL, and AMED. The Quality Appraisal of Reliability Studies Checklist (QAREL) was used to assess risk of bias. Eleven studies were included, comprising tests of active and passive movement and pain evaluating participants with ongoing neck pain. One study was assessed with a low risk of bias, three with medium risk, while the rest were assessed with high risk of bias. The results showed differing reliabilities for the included tests ranging from poor to almost perfect. In conclusion, active movement and pain for pain or mobility overall presented acceptable to very good reliability (Kappa >0.40); while passive intervertebral tests had lower Kappa values, suggesting poor reliability. It may be a coincidence that the studies indicating very good reliability tended to be of higher quality (low to moderate risk of bias), while studies finding poor reliability tended to be of lower quality (high risk of bias). Regardless, the current recommendation from this review would suggest the clinical use of tests with acceptable reliability and avoiding the use of tests that have been shown to not be reliable. Finally, it is critical that all future reliability studies are of higher quality with low risk of bias.

  12. Reliability Analysis on NPP's Safety-Related Control Module with Field Data

    International Nuclear Information System (INIS)

    Lee, Sang Yong; Jung, Jae Hyun; Kim, Seong Hun

    2006-01-01

    The automatic control systems used in nuclear power plant (NPP) consists of numerous control modules that can be considered to be a network of components various complex ways. The control modules require relatively high reliability than industrial electronic products. Reliability prediction provides the rational basis of system designs and also provides the safety significance of system operations. The aim of this paper is to minimize the deficiencies of the traditional reliability prediction method calculation using the available field return data. This way is possible to do more realistic reliability assessment. SAMCHANG Enterprise Company (SEC) has established database containing high quality data at the module and component level from module maintenance in NPP. On the basis of these, this paper compares results that add failure record (field data) to Telcordia-SR-332 reliability prediction model with MIL-HDBK-217F prediction results

  13. A Novel Reliability Enhanced Handoff Method in Future Wireless Heterogeneous Networks

    Directory of Open Access Journals (Sweden)

    Wang YuPeng

    2016-01-01

    Full Text Available As the demand increases, future networks will follow the trends of network variety and service flexibility, which requires heterogeneous type of network deployment and reliable communication method. In practice, most communication failure happens due to the bad radio link quality, i.e., high-speed users suffers a lot on the problem of radio link failure, which causes the problem of communication interrupt and radio link recovery. To make the communication more reliable, especially for the high mobility users, we propose a novel communication handoff mechanism to reduce the occurrence of service interrupt. Based on computer simulation, we find that the reliability on the service is greatly improved.

  14. Reliability and validity of non-radiographic methods of thoracic kyphosis measurement: a systematic review.

    Science.gov (United States)

    Barrett, Eva; McCreesh, Karen; Lewis, Jeremy

    2014-02-01

    A wide array of instruments are available for non-invasive thoracic kyphosis measurement. Guidelines for selecting outcome measures for use in clinical and research practice recommend that properties such as validity and reliability are considered. This systematic review reports on the reliability and validity of non-invasive methods for measuring thoracic kyphosis. A systematic search of 11 electronic databases located studies assessing reliability and/or validity of non-invasive thoracic kyphosis measurement techniques. Two independent reviewers used a critical appraisal tool to assess the quality of retrieved studies. Data was extracted by the primary reviewer. The results were synthesized qualitatively using a level of evidence approach. 27 studies satisfied the eligibility criteria and were included in the review. The reliability, validity and both reliability and validity were investigated by sixteen, two and nine studies respectively. 17/27 studies were deemed to be of high quality. In total, 15 methods of thoracic kyphosis were evaluated in retrieved studies. All investigated methods showed high (ICC ≥ .7) to very high (ICC ≥ .9) levels of reliability. The validity of the methods ranged from low to very high. The strongest levels of evidence for reliability exists in support of the Debrunner kyphometer, Spinal Mouse and Flexicurve index, and for validity supports the arcometer and Flexicurve index. Further reliability and validity studies are required to strengthen the level of evidence for the remaining methods of measurement. This should be addressed by future research. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Development of improved processing and evaluation methods for high reliability structural ceramics for advanced heat engine applications Phase II. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Pujari, V.J.; Tracey, D.M.; Foley, M.R. [and others

    1996-02-01

    The research program had as goals the development and demonstration of significant improvements in processing methods, process controls, and nondestructive evaluation (NDE) which can be commercially implemented to produce high reliability silicon nitride components for advanced heat engine applications at temperatures to 1370{degrees}C. In Phase I of the program a process was developed that resulted in a silicon nitride - 4 w% yttria HIP`ed material (NCX 5102) that displayed unprecedented strength and reliability. An average tensile strength of 1 GPa and a strength distribution following a 3-parameter Weibull distribution were demonstrated by testing several hundred buttonhead tensile specimens. The Phase II program focused on the development of methodology for colloidal consolidation producing green microstructure which minimizes downstream process problems such as drying, shrinkage, cracking, and part distortion during densification. Furthermore, the program focused on the extension of the process to gas pressure sinterable (GPS) compositions. Excellent results were obtained for the HIP composition processed for minimal density gradients, both with respect to room-temperature strength and high-temperature creep resistance. Complex component fabricability of this material was demonstrated by producing engine-vane prototypes. Strength data for the GPS material (NCX-5400) suggest that it ranks very high relative to other silicon nitride materials in terms of tensile/flexure strength ratio, a measure of volume quality. This high quality was derived from the closed-loop colloidal process employed in the program.

  16. Sub-nanosecond jitter, repetitive impulse generators for high reliability applications

    International Nuclear Information System (INIS)

    Krausse, G.J.; Sarjeant, W.J.

    1981-01-01

    Low jitter, high reliability impulse generator development has recently become of ever increasing importance for developing nuclear physics and weapons applications. The research and development of very low jitter (< 30 ps), multikilovolt generators for high reliability, minimum maintenance trigger applications utilizing a new class of high-pressure tetrode thyratrons now commercially available are described. The overall system design philosophy is described followed by a detailed analysis of the subsystem component elements. A multi-variable experimental analysis of this new tetrode thyratron was undertaken, in a low-inductance configuration, as a function of externally available parameters. For specific thyratron trigger conditions, rise times of 18 ns into 6.0-Ω loads were achieved at jitters as low as 24 ps. Using this database, an integrated trigger generator system with solid-state front-end is described in some detail. The generator was developed to serve as the Master Trigger Generator for a large neutrino detector installation at the Los Alamos Meson Physics Facility

  17. Reliable on-line storage in the ALICE High-Level Trigger

    Energy Technology Data Exchange (ETDEWEB)

    Kalcher, Sebastian; Lindenstruth, Volker [Kirchhoff Institute of Physics, University of Heidelberg (Germany)

    2009-07-01

    The on-line disk capacity within large computing clusters such as used in the ALICE High-Level Trigger (HLT) is often not used due to the inherent unreliability of the involved disks. With currently available hard drive capacities the total on-line capacity can be significant when compared to the storage requirements of present high energy physics experiments. In this talk we report on ClusterRAID, a reliable, distributed mass storage system, which allows to harness the (often unused) disk capacities of large cluster installations. The key paradigm of this system is to transform the local hard drive into a reliable device. It provides adjustable fault-tolerance by utilizing sophisticated error-correcting codes. To reduce the costs of coding and decoding operations the use of modern graphics processing units as co-processor has been investigated. Also, the utilization of low overhead, high performance communication networks has been examined. A prototype set up of the system exists within the HLT with 90 TB gross capacity.

  18. High level issues in reliability quantification of safety-critical software

    International Nuclear Information System (INIS)

    Kim, Man Cheol

    2012-01-01

    For the purpose of developing a consensus method for the reliability assessment of safety-critical digital instrumentation and control systems in nuclear power plants, several high level issues in reliability assessment of the safety-critical software based on Bayesian belief network modeling and statistical testing are discussed. Related to the Bayesian belief network modeling, the relation between the assessment approach and the sources of evidence, the relation between qualitative evidence and quantitative evidence, how to consider qualitative evidence, and the cause-consequence relation are discussed. Related to the statistical testing, the need of the consideration of context-specific software failure probabilities and the inability to perform a huge number of tests in the real world are discussed. The discussions in this paper are expected to provide a common basis for future discussions on the reliability assessment of safety-critical software. (author)

  19. Near-misses are an opportunity to improve patient safety: adapting strategies of high reliability organizations to healthcare.

    Science.gov (United States)

    Van Spall, Harriette; Kassam, Alisha; Tollefson, Travis T

    2015-08-01

    Near-miss investigations in high reliability organizations (HROs) aim to mitigate risk and improve system safety. Healthcare settings have a higher rate of near-misses and subsequent adverse events than most high-risk industries, but near-misses are not systematically reported or analyzed. In this review, we will describe the strategies for near-miss analysis that have facilitated a culture of safety and continuous quality improvement in HROs. Near-miss analysis is routine and systematic in HROs such as aviation. Strategies implemented in aviation include the Commercial Aviation Safety Team, which undertakes systematic analyses of near-misses, so that findings can be incorporated into Standard Operating Procedures (SOPs). Other strategies resulting from incident analyses include Crew Resource Management (CRM) for enhanced communication, situational awareness training, adoption of checklists during operations, and built-in redundancy within systems. Health care organizations should consider near-misses as opportunities for quality improvement. The systematic reporting and analysis of near-misses, commonplace in HROs, can be adapted to health care settings to prevent adverse events and improve clinical outcomes.

  20. Transferring Aviation Practices into Clinical Medicine for the Promotion of High Reliability.

    Science.gov (United States)

    Powell-Dunford, Nicole; McPherson, Mark K; Pina, Joseph S; Gaydos, Steven J

    2017-05-01

    Aviation is a classic example of a high reliability organization (HRO)-an organization in which catastrophic events are expected to occur without control measures. As health care systems transition toward high reliability, aviation practices are increasingly transferred for clinical implementation. A PubMed search using the terms aviation, crew resource management, and patient safety was undertaken. Manuscripts authored by physician pilots and accident investigation regulations were analyzed. Subject matter experts involved in adoption of aviation practices into the medical field were interviewed. A PubMed search yielded 621 results with 22 relevant for inclusion. Improved clinical outcomes were noted in five research trials in which aviation practices were adopted, particularly with regard to checklist usage and crew resource-management training. Effectiveness of interventions was influenced by intensity of application, leadership involvement, and provision of staff training. The usefulness of incorporating mishap investigation techniques has not been established. Whereas aviation accident investigation is highly standardized, the investigation of medical error is characterized by variation. The adoption of aviation practices into clinical medicine facilitates an evolution toward high reliability. Evidence for the efficacy of the checklist and crew resource-management training is robust. Transference of aviation accident investigation practices is preliminary. A standardized, independent investigation process could facilitate the development of a safety culture commensurate with that achieved in the aviation industry.Powell-Dunford N, McPherson MK, Pina JS, Gaydos SJ. Transferring aviation practices into clinical medicine for the promotion of high reliability. Aerosp Med Hum Perform. 2017; 88(5):487-491.

  1. Reliability of force-velocity relationships during deadlift high pull.

    Science.gov (United States)

    Lu, Wei; Boyas, Sébastien; Jubeau, Marc; Rahmani, Abderrahmane

    2017-11-13

    This study aimed to evaluate the within- and between-session reliability of force, velocity and power performances and to assess the force-velocity relationship during the deadlift high pull (DHP). Nine participants performed two identical sessions of DHP with loads ranging from 30 to 70% of body mass. The force was measured by a force plate under the participants' feet. The velocity of the 'body + lifted mass' system was calculated by integrating the acceleration and the power was calculated as the product of force and velocity. The force-velocity relationships were obtained from linear regression of both mean and peak values of force and velocity. The within- and between-session reliability was evaluated by using coefficients of variation (CV) and intraclass correlation coefficients (ICC). Results showed that DHP force-velocity relationships were significantly linear (R² > 0.90, p  0.94), mean and peak velocities showed a good agreement (CV reliable and can therefore be utilised as a tool to characterise individuals' muscular profiles.

  2. Direct unavailability computation of a maintained highly reliable system

    Czech Academy of Sciences Publication Activity Database

    Briš, R.; Byczanski, Petr

    2010-01-01

    Roč. 224, č. 3 (2010), s. 159-170 ISSN 1748-0078 Grant - others:GA Mšk(CZ) MSM6198910007 Institutional research plan: CEZ:AV0Z30860518 Keywords : high reliability * availability * directed acyclic graph Subject RIV: BA - General Mathematics http:// journals .pepublishing.com/content/rtp3178l17923m46/

  3. Implementing eco friendly highly reliable upload feature using multi 3G service

    Science.gov (United States)

    Tanutama, Lukas; Wijaya, Rico

    2017-12-01

    The current trend of eco friendly Internet access is preferred. In this research the understanding of eco friendly is minimum power consumption. The devices that are selected have operationally low power consumption and normally have no power consumption as they are hibernating during idle state. To have the reliability a router of a router that has internal load balancing feature will provide the improvement of previous research on multi 3G services for broadband lines. Previous studies emphasized on accessing and downloading information files from Public Cloud residing Web Servers. The demand is not only for speed but high reliability of access as well. High reliability will mean mitigating both direct and indirect high cost due to repeated attempts of uploading and downloading the large files. Nomadic and mobile computer users need viable solution. Following solution for downloading information has been proposed and tested. The solution is promising. The result is now extended to providing reliable access line by means of redundancy and automatic reconfiguration for uploading and downloading large information files to a Web Server in the Cloud. The technique is taking advantage of internal load balancing feature to provision a redundant line acting as a backup line. A router that has the ability to provide load balancing to several WAN lines is chosen. The WAN lines are constructed using multiple 3G lines. The router supports the accessing Internet with more than one 3G access line which increases the reliability and availability of the Internet access as the second line immediately takes over if the first line is disturbed.

  4. Reliable and Valid Assessment of Point-of-care Ultrasonography

    DEFF Research Database (Denmark)

    Todsen, Tobias; Tolsgaard, Martin Grønnebæk; Olsen, Beth Härstedt

    2015-01-01

    physicians' OSAUS scores with diagnostic accuracy. RESULTS: The generalizability coefficient was high (0.81) and a D-study demonstrated that 1 assessor and 5 cases would result in similar reliability. The construct validity of the OSAUS scale was supported by a significant difference in the mean scores......OBJECTIVE: To explore the reliability and validity of the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale for point-of-care ultrasonography (POC US) performance. BACKGROUND: POC US is increasingly used by clinicians and is an essential part of the management of acute surgical...... conditions. However, the quality of performance is highly operator-dependent. Therefore, reliable and valid assessment of trainees' ultrasonography competence is needed to ensure patient safety. METHODS: Twenty-four physicians, representing novices, intermediates, and experts in POC US, scanned 4 different...

  5. Structural and reliability analysis of quality of relationship index in cancer patients.

    Science.gov (United States)

    Cousson-Gélie, Florence; de Chalvron, Stéphanie; Zozaya, Carole; Lafaye, Anaïs

    2013-01-01

    Among psychosocial factors affecting emotional adjustment and quality of life, social support is one of the most important and widely studied in cancer patients, but little is known about the perception of support in specific significant relationships in patients with cancer. This study examined the psychometric properties of the Quality of Relationship Inventory (QRI) by evaluating its factor structure and its convergent and discriminant validity in a sample of cancer patients. A total of 388 patients completed the QRI. Convergent validity was evaluated by testing the correlations between the QRI subscales and measures of general social support, anxiety and depression symptoms. Discriminant validity was examined by testing group comparison. The QRI's longitudinal invariance across time was also tested. Principal axis factor analysis with promax rotation identified three factors accounting for 42.99% of variance: perceived social support, depth, and interpersonal conflict. Estimates of reliability with McDonald's ω coefficient were satisfactory for all the QRI subscales (ω ranging from 0.75 - 0.85). Satisfaction from general social support was negatively correlated with the interpersonal conflict subscale and positively with the depth subscale. The interpersonal conflict and social support scales were correlated with depression and anxiety scores. We also found a relative stability of QRI subscales (measured 3 months after the first evaluation) and differences between partner status and gender groups. The Quality of Relationship Inventory is a valid tool for assessing the quality of social support in a particular relationship with cancer patients.

  6. Reliability of a Computerized Neurocognitive Test in Baseline Concussion Testing of High School Athletes.

    Science.gov (United States)

    MacDonald, James; Duerson, Drew

    2015-07-01

    Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing

  7. Inter-rater reliability of healthcare professional skills' portfolio assessments: The Andalusian Agency for Healthcare Quality model

    Directory of Open Access Journals (Sweden)

    Antonio Almuedo-Paz

    2014-07-01

    Full Text Available This study aims to determine the reliability of assessment criteria used for a portfolio at the Andalusian Agency for Healthcare Quality (ACSA. Data: all competences certification processes, regardless of their discipline. Period: 2010-2011. Three types of tests are used: 368 certificates, 17,895 reports and 22,642 clinical practice reports (N = 3,010 candidates. The tests were evaluated in pairs by the ACSA team of raters using two categories: valid and invalid. Results: The percentage agreement in assessments of certificates was 89,9%, while for the reports of clinical practice was 85,1 % and for clinical practice reports was 81,7%. The inter-rater agreement coefficients (kappa ranged from 0,468 to 0,711. Discussion: The results of this study show that the inter-rater reliability of assessments varies from fair to good. Compared with other similar studies, the results put the reliability of the model in a comfortable position. Among the improvements incorporated, progressive automation of evaluations must be highlighted.

  8. High perfomance liquid chromatography fingerprint analysis for quality control of brotowali (Tinospora crispa)

    Science.gov (United States)

    Syarifah, V. B.; Rafi, M.; Wahyuni, W. T.

    2017-05-01

    Brotowali (Tinospora crispa) is widely used in Indonesia as ingredient of herbal medicine formulation. To ensure the quality, safety, and efficacy of herbal medicine products, its chemical constituents should be continuously evaluated. High performance liquid chromatography (HPLC) fingerprint is one of powerful technique for this quality control process. In this study, HPLC fingerprint analysis method was developed for quality control of brotowali. HPLC analysis was performed in C18 column and detection was performed using photodiode array detector. The optimum mobile phase for brotowali fingerprint was acetonitrile (ACN) and 0.1% formic acid in gradient elution mode at a flow rate of 1 mL/min. The number of peaks detected in HPLC fingerprint of brotowali was 32 peaks and 23 peaks for stems and leaves, respectively. Berberine as marker compound was detected at retention time of 20.525 minutes. Evaluation of analytical performance including precision, reproducibility, and stability prove that this HPLC fingerprint analysis was reliable and could be applied for quality control of brotowali.

  9. Validity and reliability of the Brief version of Quality of Life in Bipolar Disorder" (Bref QoL.BD) among Chinese bipolar patients.

    Science.gov (United States)

    Xiao, Lin; Gao, Yulin; Zhang, Lili; Chen, Peiyun; Sun, Xiaojia; Tang, Siyuan

    2016-03-15

    Previous literatures on quality of life (QoL) in bipolar disorder (BD) strongly suggested that a disease-specific QoL measure for patients with BD should be developed to evaluate QoL more specifically and reliably. To our knowledge, "Quality of Life in Bipolar Disorder" (QoL.BD) is the first and only questionnaire produced to specifically measure QoL in people with BD. In China, there is no disease-targeted measure available to specifically measure QoL in Chinese patients with BD. The aim of the study is to revise and validate the brief version of the QoL.BD (Bref QoL.BD ) into Chinese version. All the items of the Bref QoL.BD was translated into Chinese language, using the Brislin translation mode. The questionnaire was administered to a total sample of 231 subjects, including 101 BD patients and 130 healthy controls, to test the psychometric properties of Bref QoL.BD (e.g. internal consistency, retest reliability, content validity, item analysis, confirmatory factor analysis, criterion validity, convergent validity, discriminative validity and feasibility). The Chinese version of the Bref QoL.BD had very high internal consistency (Cronbach's alpha=0.815) and retest reliability (intraclass correlation coefficient (ICC )=0.808). Confirmatory factor analysis (CFA) validated the original one-factor structure. The direction and magnitude of correlations with 36-item Short-Form Health Survey (SF-36; rs= 0.313, Psize from only one tertiary care center. And BD patients enrolled were euthymic, excluding the acute BD patients. The Chinese version of the Bref QoL.BD is a feasible, reliable and valid tool for the assessment of QoL for Chinese BD patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Translation, cultural adaptation assessment, and both validity and reliability testing of the kidney disease quality of life - short form version 1.3 for use with Iranian patients

    DEFF Research Database (Denmark)

    Pakpour, Amir; Yekaninejad, Mirsaeed; Mølsted, Stig

    2011-01-01

    AIM: The aims of the study were to translate the Kidney Disease Quality of Life--Short Form version 1.3 (KDQOL-SF ver. 1.3) questionnaire into Iranian (Farsi), and to then assess it in terms of validity and reliability on Iranian patients. METHODS: The questionnaire was first translated into Farsi...... a larger group (212 patients with end-stage renal disease on haemodialysis). Afterwards, reliability was estimated by internal consistency, and validity was assessed using known group comparisons and constructs for the patient group as a whole. Finally, the factor structure of the questionnaire...... be summarized into an 11 factor structure that jointly accounted for 79.81% of the variance. CONCLUSION: The Iranian version of the KDQOL-SF questionnaire is both highly reliable and valid for use with Iranian patients on haemodialysis....

  11. Research on reliability measures of the main transformer and GIS equipment manufacturing process

    International Nuclear Information System (INIS)

    Wu Honglong

    2014-01-01

    Based on the accidents of the main transformer GIS equipment and the accidents of the high voltage switch equipment, combined with the main transformer switch equipment maintenance experience and electrical theory, the reliability measures of the main transformer GIS equipment during manufacturing stage are studied and improved. Six successful reliability measures are identified: 1) design properly and check the ability of transformer for anti short circuit; 2) choose mature and reliable main transformer HV bushing; 3) choose GIS switch operation mechanism of high quality and reliability; 4) ensure that the insulation margin through tests piece by piece on withstand voltage and partial discharge of the GIS equipment insulation; 5) take test measures such as GIS conductor, shell polishing witness process and full form lightning impulse, to find out and eliminate the defects of abnormal electric field distribution; 6) Anti VFTO design for the main transformer connected with GIS with the voltage of 500 kV should be considered, and its anti VFTO ability to meet the safe operation under VFTO requirements should be checked. This paper proposed 2 new measures: 1) the main transformer insulation material quality standard is determined not only by its high dielectric strength, but more importantly by the homogeneous dielectric electric strength. Insulating Materials with a high and also uniform dielectric strength should be chosen. 2) During the silver-coating stage of the GIS equipment conductor, QC group activities should be organized to ensure that the plating layer quality, and the current lap surface DC resistance measurements should be supervised and witnessed to ensure the quality of the conductor contact surface. These measures are verified in Fuqing project of GIS main transformer equipment manufacturing process, and their effectiveness is proven. (author)

  12. Leadership in organizations with high security and reliability requirements

    International Nuclear Information System (INIS)

    Gonzalez, F.

    2013-01-01

    Developing leadership skills in organizations is the key to ensure the sustainability of excellent results in industries with high requirements safety and reliability. In order to have a model of leadership development specific to this type of organizations, Tecnatom in 2011, we initiated a project internal, to find and adapt a competency model to these requirements.

  13. Zerodur polishing process for high surface quality and high efficiency

    International Nuclear Information System (INIS)

    Tesar, A.; Fuchs, B.

    1992-08-01

    Zerodur is a glass-ceramic composite importance in applications where temperature instabilities influence optical and mechanical performance, such as in earthbound and spaceborne telescope mirror substrates. Polished Zerodur surfaces of high quality have been required for laser gyro mirrors. Polished surface quality of substrates affects performance of high reflection coatings. Thus, the interest in improving Zerodur polished surface quality has become more general. Beyond eliminating subsurface damage, high quality surfaces are produced by reducing the amount of hydrated material redeposited on the surface during polishing. With the proper control of polishing parameters, such surfaces exhibit roughnesses of < l Angstrom rms. Zerodur polishing was studied to recommend a high surface quality polishing process which could be easily adapted to standard planetary continuous polishing machines and spindles. This summary contains information on a polishing process developed at LLNL which reproducibly provides high quality polished Zerodur surfaces at very high polishing efficiencies

  14. [Quality management is associated with high quality services in health care].

    Science.gov (United States)

    Nielsen, Tenna Hassert; Riis, Allan; Mainz, Jan; Jensen, Anne-Louise Degn

    2013-12-09

    In these years, quality management has been the focus in order to meet high quality services for the patients in Danish health care. This article provides information on quality management and quality improvement and it evaluates its effectiveness in achieving better organizational structures, processes and results in Danish health-care organizations. Our findings generally support that quality management is associated with high quality services in health care.

  15. Validation of Land Cover Products Using Reliability Evaluation Methods

    Directory of Open Access Journals (Sweden)

    Wenzhong Shi

    2015-06-01

    Full Text Available Validation of land cover products is a fundamental task prior to data applications. Current validation schemes and methods are, however, suited only for assessing classification accuracy and disregard the reliability of land cover products. The reliability evaluation of land cover products should be undertaken to provide reliable land cover information. In addition, the lack of high-quality reference data often constrains validation and affects the reliability results of land cover products. This study proposes a validation schema to evaluate the reliability of land cover products, including two methods, namely, result reliability evaluation and process reliability evaluation. Result reliability evaluation computes the reliability of land cover products using seven reliability indicators. Process reliability evaluation analyzes the reliability propagation in the data production process to obtain the reliability of land cover products. Fuzzy fault tree analysis is introduced and improved in the reliability analysis of a data production process. Research results show that the proposed reliability evaluation scheme is reasonable and can be applied to validate land cover products. Through the analysis of the seven indicators of result reliability evaluation, more information on land cover can be obtained for strategic decision-making and planning, compared with traditional accuracy assessment methods. Process reliability evaluation without the need for reference data can facilitate the validation and reflect the change trends of reliabilities to some extent.

  16. The reliability and validity of the short version of the WHO Quality of Life Instrument in an Arab general population

    International Nuclear Information System (INIS)

    Ohaeri, Jude U; Awadallab, Abdel W

    2009-01-01

    There is rising interest in quality of life (QOL) research in Arabian countries. The aim of this study was to assess in a nationwide sample of Kuwaiti subjects the reliability and validity of the World Health Organization Quality of Life (WHOQOL-BREF), a shorter version of the widely used QOL assessment instrument that comprises 26 items in the domains of physical health, psychological health, social relationships, and the environment. A one-in-three systematic random proportionate sample of consenting Kuwaiti nationals attending large cooperative stores and municipal government offices in the six governorates completed the Arabic translation of the questionnaire. The indices assessed included test-retest reliability, internal consistency, item internal consistency (2C), item discriminant validity (IDV), known-groups and construct validity. There were 3303 participants (44.8% males, 55.2% females, mean age 35.4 years, range 16 to 87 years). The intra-class correlation for the test-retest statistic and the internal consistency values for the full questionnaire and the domains had a Cronbach's alpha > - 0.7. Of the 24 items that constitute the domains, 21 met the 2 C requirement of correlation > - 0.4 with the corresponding domain, while 16 met the IDV criterion of having a higher correlation with their corresponding domain than other domains. Domain scores discriminated significantly between well and sick groups. In the factor analysis, four strong factors emerged with the same construct as in the WHO report. The Arabic translation of the WHOQOL-BREF has impressive reliability and validity indices. The poor IDV findings are due to the multidimensional nature of the questionnaire. The highly significant validity indices should reassure researchers that the questionnaire represents the same constructs across cultures. Negatively worded items possibly need refinement. (author)

  17. A feasible, aesthetic quality evaluation of implant-supported single crowns: an analysis of validity and reliability

    DEFF Research Database (Denmark)

    Hosseini, Mandana; Gotfredsen, Klaus

    2012-01-01

    OBJECTIVES: To test the reliability and validity of six aesthetic parameters and to compare the professional- and patient-reported aesthetic outcomes. MATERIAL AND METHODS: Thirty-four patients with 66 implant-supported premolar crowns were included. Two prosthodontists and 11 dental students......,24) were found between patient and professional evaluations. CONCLUSIONS: The feasibility, reliability and validity of the CIS make the parameters useful for quality control of implant-supported restorations. The professional- and patient-reported aesthetic outcomes had no significant correlation....... and the internal consistency were analysed by Cohen's ¿ and Cronbach's a, respectively. The validity of CIS parameters was tested against the corresponding Visual Analogue Scales (VAS) scores. The Spearman correlation coefficients were used. Six aesthetic Oral Health Impact Profile (OHIP) questions were correlated...

  18. Comprehensive low-cost reliability centered maintenance. Final report

    International Nuclear Information System (INIS)

    Rotton, S.J.; Dozier, I.J.; Thow, R.

    1995-09-01

    Reliability Centered Maintenance (RCM) is a maintenance optimization approach that all electric utilities can apply to power plant systems. The Electric Power Research Institute and PECO Energy Company jointly sponsored this Comprehensive Low-Cost Reliability Centered Maintenance project to demonstrate that the standard RCM methodology could be streamlined to reduce the cost of analysis while maintaining a high quality product. EPRI's previous investigation of streamlined RCM methods being pioneered in the nuclear industry indicated that PECO Energy could expect to optimize its maintenance program at reduced cost by carefully controlling the scope without sacrificing documentation or technical quality. Using the insights obtained from these previous studies, three methods were defined in this project and were demonstrated in a large scale application to 60 systems at both the Limerick Generating Station and the Peach Bottom Atomic Power Station

  19. Surviving the Lead Reliability Engineer Role in High Unit Value Projects

    Science.gov (United States)

    Perez, Reinaldo J.

    2011-01-01

    A project with a very high unit value within a company is defined as a project where a) the project constitutes one of a kind (or two-of-a-kind) national asset type of project, b) very large cost, and c) a mission failure would be a very public event that will hurt the company's image. The Lead Reliability engineer in a high visibility project is by default involved in all phases of the project, from conceptual design to manufacture and testing. This paper explores a series of lessons learned, over a period of ten years of practical industrial experience by a Lead Reliability Engineer. We expand on the concepts outlined by these lessons learned via examples. The lessons learned are applicable to all industries.

  20. Reliability engineering for nuclear and other high technology systems

    International Nuclear Information System (INIS)

    Lakner, A.A.; Anderson, R.T.

    1985-01-01

    This book is written for the reliability instructor, program manager, system engineer, design engineer, reliability engineer, nuclear regulator, probability risk assessment (PRA) analyst, general manager and others who are involved in system hardware acquisition, design and operation and are concerned with plant safety and operational cost-effectiveness. It provides criteria, guidelines and comprehensive engineering data affecting reliability; it covers the key aspects of system reliability as it relates to conceptual planning, cost tradeoff decisions, specification, contractor selection, design, test and plant acceptance and operation. It treats reliability as an integrated methodology, explicitly describing life cycle management techniques as well as the basic elements of a total hardware development program, including: reliability parameters and design improvement attributes, reliability testing, reliability engineering and control. It describes how these elements can be defined during procurement, and implemented during design and development to yield reliable equipment. (author)

  1. Integrated reliability condition monitoring and maintenance of equipment

    CERN Document Server

    Osarenren, John

    2015-01-01

    Consider a Viable and Cost-Effective Platform for the Industries of the Future (IOF) Benefit from improved safety, performance, and product deliveries to your customers. Achieve a higher rate of equipment availability, performance, product quality, and reliability. Integrated Reliability: Condition Monitoring and Maintenance of Equipment incorporates reliable engineering and mathematical modeling to help you move toward sustainable development in reliability condition monitoring and maintenance. This text introduces a cost-effective integrated reliability growth monitor, integrated reliability degradation monitor, technological inheritance coefficient sensors, and a maintenance tool that supplies real-time information for predicting and preventing potential failures of manufacturing processes and equipment. The author highlights five key elements that are essential to any improvement program: improving overall equipment and part effectiveness, quality, and reliability; improving process performance with maint...

  2. Highly-reliable operation of 638-nm broad stripe laser diode with high wall-plug efficiency for display applications

    Science.gov (United States)

    Yagi, Tetsuya; Shimada, Naoyuki; Nishida, Takehiro; Mitsuyama, Hiroshi; Miyashita, Motoharu

    2013-03-01

    Laser based displays, as pico to cinema laser projectors have gathered much attention because of wide gamut, low power consumption, and so on. Laser light sources for the displays are operated mainly in CW, and heat management is one of the big issues. Therefore, highly efficient operation is necessitated. Also the light sources for the displays are requested to be highly reliable. 638 nm broad stripe laser diode (LD) was newly developed for high efficiency and highly reliable operation. An AlGaInP/GaAs red LD suffers from low wall plug efficiency (WPE) due to electron overflow from an active layer to a p-cladding layer. Large optical confinement factor (Γ) design with AlInP cladding layers is adopted to improve the WPE. The design has a disadvantage for reliable operation because the large Γ causes high optical density and brings a catastrophic optical degradation (COD) at a front facet. To overcome the disadvantage, a window-mirror structure is also adopted in the LD. The LD shows WPE of 35% at 25°C, highest record in the world, and highly stable operation at 35°C, 550 mW up to 8,000 hours without any catastrophic optical degradation.

  3. High reliability fuel in the US

    International Nuclear Information System (INIS)

    Neuhold, R.J.; Leggett, R.D.; Walters, L.C.; Matthews, R.B.

    1986-05-01

    The fuels development program of the United States is described for liquid metal reactors (LMR's). The experience base, status and future potential are discussed for the three systems - oxide, metal and carbide - that have proved to have high reliability. Information is presented showing burnup capability of the oxide fuel system in a large core, e.g., FFTF, to be 150 MWd/kgM with today's technology with the potential for a capability as high as 300 MWd/kgM. Data provided for the metal fuel system show 8 at. % being routinely achieved as the EBR-II driver fuel with good potential for extending this to 15 at. % since special test pins have already exceeded this burnup level. The data included for the carbide fuel system are from pin and assembly irradiations in EBR-II and FFTF, respectively. Burnup to 12 at. % appears readily achievable with burnups to 20 at. % being demonstrated in a few pins. Efforts continue on all three systems with the bulk of the activity on metal and oxide

  4. Reliability of an Automated High-Resolution Manometry Analysis Program across Expert Users, Novice Users, and Speech-Language Pathologists

    Science.gov (United States)

    Jones, Corinne A.; Hoffman, Matthew R.; Geng, Zhixian; Abdelhalim, Suzan M.; Jiang, Jack J.; McCulloch, Timothy M.

    2014-01-01

    Purpose: The purpose of this study was to investigate inter- and intrarater reliability among expert users, novice users, and speech-language pathologists with a semiautomated high-resolution manometry analysis program. We hypothesized that all users would have high intrarater reliability and high interrater reliability. Method: Three expert…

  5. Improved reliability of power modules

    DEFF Research Database (Denmark)

    Baker, Nick; Liserre, Marco; Dupont, Laurent

    2014-01-01

    Power electronic systems play an increasingly important role in providing high-efficiency power conversion for adjustable-speed drives, power-quality correction, renewable-energy systems, energy-storage systems, and electric vehicles. However, they are often presented with demanding operating...... environments that challenge the reliability aspects of power electronic techniques. For example, increasingly thermally stressful environments are seen in applications such as electric vehicles, where ambient temperatures under the hood exceed 150 °C, while some wind turbine applications can place large...

  6. USING A TOTAL QUALITY STRATEGY IN A NEW PRACTICAL APPROACH FOR IMPROVING THE PRODUCT RELIABILITY IN AUTOMOTIVE INDUSTRY

    Directory of Open Access Journals (Sweden)

    Cristiano Fragassa

    2014-09-01

    Full Text Available In this paper a Total Quality Management strategy is proposed, refined and used with the aim at improving the quality of large-mass industrial products far beyond the technical specifications demanded at the end-customer level. This approach combines standard and non-standard tools used for Reliability, Availability and Maintainability analysis. The procedure also realizes a stricter correlation between theoretical evaluation methods and experimental evidences as part of a modern integrated method for strengthening quality in design and process. A commercial Intake Manifold, largely spread in the market, is used as test-case for the validation of the methodology. As general additional result, the research underlines the impact of Total Quality Management and its tools on the development of innovation.

  7. Thermal performance envelopes for MHTGRs - Reliability by design

    International Nuclear Information System (INIS)

    Etzel, K.T.; Howard, W.W.; Zgliczynski, J.

    1992-01-01

    Thermal performance envelopes are used to specify steady-state design requirements for the systems of the modular high-temperature gas-cooled reactor (MHTGR) to maximize plant performance reliability with optimized design. The thermal performance envelopes are constructed around the expected operating point to account for uncertainties in actual plant as-built parameters and plant operation. The components are then designed to perform successfully at all points within the envelope. As a result, plant reliability is maximized by accounting for component thermal performance variation in the design. The design is optimized by providing a means to determine required margins in a disciplined and visible fashion. This is accomplished by coordinating these requirements with the various system and component designers in the early stages of the design, applying the principles of total quality management. The design is challenged by the more complex requirements associated with a range of operating conditions, but in return, high probability of delivering reliable performance throughout the plant life is ensured

  8. John F. Kennedy Space Center, Safety, Reliability, Maintainability and Quality Assurance, Survey and Audit Program

    Science.gov (United States)

    1994-01-01

    This document is the product of the KSC Survey and Audit Working Group composed of civil service and contractor Safety, Reliability, and Quality Assurance (SR&QA) personnel. The program described herein provides standardized terminology, uniformity of survey and audit operations, and emphasizes process assessments rather than a program based solely on compliance. The program establishes minimum training requirements, adopts an auditor certification methodology, and includes survey and audit metrics for the audited organizations as well as the auditing organization.

  9. Bayesian methods in reliability

    Science.gov (United States)

    Sander, P.; Badoux, R.

    1991-11-01

    The present proceedings from a course on Bayesian methods in reliability encompasses Bayesian statistical methods and their computational implementation, models for analyzing censored data from nonrepairable systems, the traits of repairable systems and growth models, the use of expert judgment, and a review of the problem of forecasting software reliability. Specific issues addressed include the use of Bayesian methods to estimate the leak rate of a gas pipeline, approximate analyses under great prior uncertainty, reliability estimation techniques, and a nonhomogeneous Poisson process. Also addressed are the calibration sets and seed variables of expert judgment systems for risk assessment, experimental illustrations of the use of expert judgment for reliability testing, and analyses of the predictive quality of software-reliability growth models such as the Weibull order statistics.

  10. Surfing Behind a Boat: Quality and Reliability of Online Resources on Scaphoid Fractures.

    Science.gov (United States)

    Nassiri, Mujtaba; Mohamed, Osama; Berzins, Arvids; Aljabi, Yasser; Mahmood, Talat; Chenouri, Shojaeddin; O'Grady, Paul

    2016-10-01

    Patients seeking information and advice on treatment of scaphoid fractures unknowingly confront longstanding medical controversies surrounding the management of this condition. However, there are no studies specifically looking into the quality and reliability of online information on scaphoid fractures. We identified 44 unique websites for evaluation using the term "scaphoid fractures". The websites were categorized by type and assessed using the DISCERN score, the Journal of the American Medical Association (JAMA) benchmark criteria and the Health on the net (HON) code. The majority of websites were commercial (n = 13) followed by academic (n = 12). Only seven of the websites were HON certified. The mean DISCERN score was 43.8. Only 4 websites scored 63 or above representing excellent quality with minimal shortcomings but 13 websites scored 38 or below representing poor or very poor quality. The mean JAMA benchmark criteria score was 2.2. The Governmental and Non-Profit Organizations category websites had the highest mean JAMA benchmark score. The websites that displayed the HON-code seal had higher mean DISCERN scores and higher mean JAMA benchmark scores compared to websites that did not display the seal. Good quality health information is certainly available on the Internet. However, it is not possible to predict with certainty which sites are of higher quality. We suggest clinicians should have a responsibility to educate their patients regarding the unregulated nature of medical information on the internet and proactively provide patients with educational resources and thus help them make smart and informed decisions.

  11. Verification of the reliability and validity of a Japanese version of the Quality of Life in Childhood Epilepsy Questionnaire (QOLCE-J).

    Science.gov (United States)

    Moriguchi, Eri; Ito, Mikiko; Nagai, Toshisaburo

    2015-11-01

    A Japanese version of the Quality of Life in Childhood Epilepsy Questionnaire (QOLCE-J) was developed using international guidelines as a QOL scale for childhood epilepsy; its reliability and validity were examined, focusing on Japanese pediatric epilepsy patients applicability. A pilot test questionnaire survey was conducted; involving parents of pediatric epilepsy patients aged 4-15 undergoing outpatient treatment. 278 responses were obtained and analyzed. Internal consistency for the 16 QOLCE-J subscales, except for , was sufficient, and a high overall coefficient α was obtained. The intraclass correlation coefficient was also high, supporting the test-retest reliability of this version. Associations among the subscales, high correlations of r>0.7 were observed among , , and , representing cognitive and behavioral aspects, and among these and . In contrast, correlations among others were moderate or weaker. Furthermore, correlations of r>0.35 were observed among the subscales of the SDQ (Strength and Difficulties Questionnaire) used as an external criterion and the QOLCE-J, confirming the criterion validity of the study version. Analysis of associations between the total QOLCE-J score and pathology of epilepsy, found significant correlation with age of onset and frequency of seizures, ADL, and antiepileptics side effects' symptoms. QOLCE has mostly been used in treatment resistant pediatric patients, the influence of interictal period presently observed, like antiepileptic side effects' symptoms; suggest usefulness for pediatric patients with seizures under control. The QOLCE-J with sufficient reliability and validity may be applicable as a QOL scale for Japanese children with epilepsy. Copyright © 2015 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  12. The Validity and Reliability Test of the Indonesian Version of Gastroesophageal Reflux Disease Quality of Life (GERD-QOL) Questionnaire.

    Science.gov (United States)

    Siahaan, Laura A; Syam, Ari F; Simadibrata, Marcellus; Setiati, Siti

    2017-01-01

    to obtain a valid and reliable GERD-QOL questionnaire for Indonesian application. at the initial stage, the GERD-QOL questionnaire was first translated into Indonesian language and the translated questionnaire was subsequently translated back into the original language (back-to-back translation). The results were evaluated by the researcher team and therefore, an Indonesian version of GERD-QOL questionnaire was developed. Ninety-one patients who had been clinically diagnosed with GERD based on the Montreal criteria were interviewed using the Indonesian version of GERD-QOL questionnaire and the SF 36 questionnaire. The validity was evaluated using a method of construct validity and external validity, and reliability can be tested by the method of internal consistency and test retest. the Indonesian version of GERD-QOL questionnaire had a good internal consistency reliability with a Cronbach Alpha of 0.687-0.842 and a good test retest reliability with an intra-class correlation coefficient of 0.756-0.936; pGERD-QOL questionnaire has been proven valid and reliable to evaluate the quality of life of GERD patients.

  13. Fast neutrons: Inexpensive and reliable tool to investigate high-LET particle radiobiology

    International Nuclear Information System (INIS)

    Gueulette, J.; Slabbert, J.P.; Bischoff, P.; Denis, J.M.; Wambersie, A.; Jones, D.

    2010-01-01

    Radiation therapy with carbon ions as well as missions into outer space have boosted the interest for high-LET particle radiobiology. Optimization of treatments in accordance with technical developments, as well as the radioprotection of cosmonauts during long missions require that research in these domains continue. Therefore suitable radiation fields are needed. Fast neutrons and carbon ions exhibit comparable LET values and similar radiobiological properties. Consequently, the findings obtained with each radiation quality could be shared to benefit knowledge in all concerned domains. The p(66+Be) neutron therapy facilities of iThemba LABS (South Africa) and the p(65)+Be neutron facility of Louvain-la-Neuve (Belgium) are in constant use to do radiobiological research for clinical applications with fast neutrons. These beams - which comply with all physical and technical requirements for clinical applications - are now fully reliable, easy to use and frequently accessible for radiobiological investigations. These facilities thus provide unique opportunities to undertake radiobiological experimentation, especially for investigations that require long irradiation times and/or fractionated treatments.

  14. Plastic packaged microcircuits: Quality, reliability, and cost issues

    Science.gov (United States)

    Pecht, Michael G.; Agarwal, Rakesh; Quearry, Dan

    1993-12-01

    Plastic encapsulated microcircuits (PEMs) find their main application in commercial and telecommunication electronics. The advantages of PEMs in cost, size, weight, performance, and market lead-time, have attracted 97% of the market share of worldwide microcircuit sales. However, PEMs have always been resisted in US Government and military applications due to the perception that PEM reliability is low. This paper surveys plastic packaging with respect to the issues of reliability, market lead-time, performance, cost, and weight as a means to guide part-selection and system-design.

  15. High reliable and Real-time Data Communication Network Technology for Nuclear Power Plant

    International Nuclear Information System (INIS)

    Jeong, K. I.; Lee, J. K.; Choi, Y. R.; Lee, J. C.; Choi, Y. S.; Cho, J. W.; Hong, S. B.; Jung, J. E.; Koo, I. S.

    2008-03-01

    As advanced digital Instrumentation and Control (I and C) system of NPP(Nuclear Power Plant) are being introduced to replace analog systems, a Data Communication Network(DCN) is becoming the important system for transmitting the data generated by I and C systems in NPP. In order to apply the DCNs to NPP I and C design, DCNs should conform to applicable acceptance criteria and meet the reliability and safety goals of the system. As response time is impacted by the selected protocol, network topology, network performance, and the network configuration of I and C system, DCNs should transmit a data within time constraints and response time required by I and C systems to satisfy response time requirements of I and C system. To meet these requirements, the DCNs of NPP I and C should be a high reliable and real-time system. With respect to high reliable and real-time system, several reports and techniques having influences upon the reliability and real-time requirements of DCNs are surveyed and analyzed

  16. A quality assurance initiative for commercial-scale production in high-throughput cryopreservation of blue catfish sperm.

    Science.gov (United States)

    Hu, E; Liao, T W; Tiersch, T R

    2013-10-01

    Cryopreservation of fish sperm has been studied for decades at a laboratory (research) scale. However, high-throughput cryopreservation of fish sperm has recently been developed to enable industrial-scale production. This study treated blue catfish (Ictalurus furcatus) sperm high-throughput cryopreservation as a manufacturing production line and initiated quality assurance plan development. The main objectives were to identify: (1) the main production quality characteristics; (2) the process features for quality assurance; (3) the internal quality characteristics and their specification designs; (4) the quality control and process capability evaluation methods, and (5) the directions for further improvements and applications. The essential product quality characteristics were identified as fertility-related characteristics. Specification design which established the tolerance levels according to demand and process constraints was performed based on these quality characteristics. Meanwhile, to ensure integrity throughout the process, internal quality characteristics (characteristics at each quality control point within process) that could affect fertility-related quality characteristics were defined with specifications. Due to the process feature of 100% inspection (quality inspection of every fish), a specific calculation method, use of cumulative sum (CUSUM) control charts, was applied to monitor each quality characteristic. An index of overall process evaluation, process capacity, was analyzed based on in-control process and the designed specifications, which further integrates the quality assurance plan. With the established quality assurance plan, the process could operate stably and quality of products would be reliable. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Impact of image quality on reliability of the measurements of left ventricular systolic function and global longitudinal strain in 2D echocardiography.

    Science.gov (United States)

    Nagata, Yasufumi; Kado, Yuichiro; Onoue, Takeshi; Otani, Kyoko; Nakazono, Akemi; Otsuji, Yutaka; Takeuchi, Masaaki

    2018-03-01

    Left ventricular ejection fraction (LVEF) and global longitudinal strain (GLS) play important roles in diagnosis and management of cardiac diseases. However, the issue of the accuracy and reliability of LVEF and GLS remains to be solved. Image quality is one of the most important factors affecting measurement variability. The aim of this study was to investigate whether improved image quality could reduce observer variability. Two sets of three apical images were acquired using relatively old- and new-generation ultrasound imaging systems (Vivid 7 and Vivid E95) in 308 subjects. Image quality was assessed by endocardial border delineation index (EBDI) using a 3-point scoring system. Three observers measured the LVEF and GLS, and these values and inter-observer variability were investigated. Image quality was significantly better with Vivid E95 (EBDI: 26.8 ± 5.9) than that with Vivid 7 (22.8 ± 6.3, P  image quality yielded benefits to both LVEF and GLS measurement reliability. Multivariate analysis showed that image quality was indeed an important factor of observer variability in the measurement of LVEF and GLS. The new-generation ultrasound imaging system offers improved image quality and reduces inter-observer variability in the measurement of LVEF and GLS. © 2018 The authors.

  18. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Quality Assurance Manual

    Energy Technology Data Exchange (ETDEWEB)

    C. L. Smith; R. Nims; K. J. Kvarfordt; C. Wharton

    2008-08-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment using a personal computer running the Microsoft Windows operating system. SAPHIRE is primarily funded by the U.S. Nuclear Regulatory Commission (NRC). The role of the INL in this project is that of software developer and tester. This development takes place using formal software development procedures and is subject to quality assurance (QA) processes. The purpose of this document is to describe how the SAPHIRE software QA is performed for Version 6 and 7, what constitutes its parts, and limitations of those processes.

  19. REMOTE SENSING APPLICATIONS WITH HIGH RELIABILITY IN CHANGJIANG WATER RESOURCE MANAGEMENT

    Directory of Open Access Journals (Sweden)

    L. Ma

    2018-04-01

    Full Text Available Remote sensing technology has been widely used in many fields. But most of the applications cannot get the information with high reliability and high accuracy in large scale, especially for the applications using automatic interpretation methods. We have designed an application-oriented technology system (PIR composed of a series of accurate interpretation techniques,which can get over 85 % correctness in Water Resource Management from the view of photogrammetry and expert knowledge. The techniques compose of the spatial positioning techniques from the view of photogrammetry, the feature interpretation techniques from the view of expert knowledge, and the rationality analysis techniques from the view of data mining. Each interpreted polygon is accurate enough to be applied to the accuracy sensitive projects, such as the Three Gorge Project and the South - to - North Water Diversion Project. In this paper, we present several remote sensing applications with high reliability in Changjiang Water Resource Management,including water pollution investigation, illegal construction inspection, and water conservation monitoring, etc.

  20. Remote Sensing Applications with High Reliability in Changjiang Water Resource Management

    Science.gov (United States)

    Ma, L.; Gao, S.; Yang, A.

    2018-04-01

    Remote sensing technology has been widely used in many fields. But most of the applications cannot get the information with high reliability and high accuracy in large scale, especially for the applications using automatic interpretation methods. We have designed an application-oriented technology system (PIR) composed of a series of accurate interpretation techniques,which can get over 85 % correctness in Water Resource Management from the view of photogrammetry and expert knowledge. The techniques compose of the spatial positioning techniques from the view of photogrammetry, the feature interpretation techniques from the view of expert knowledge, and the rationality analysis techniques from the view of data mining. Each interpreted polygon is accurate enough to be applied to the accuracy sensitive projects, such as the Three Gorge Project and the South - to - North Water Diversion Project. In this paper, we present several remote sensing applications with high reliability in Changjiang Water Resource Management,including water pollution investigation, illegal construction inspection, and water conservation monitoring, etc.

  1. The Effect of Patient Characteristics and Sleep Quality on Visual Field Performance Reliability

    Directory of Open Access Journals (Sweden)

    Swarup S. Swaminathan

    2018-01-01

    Full Text Available Purpose. To investigate the association of automated visual field (VF reliability indices (false positive [FP], false negative [FN], and fixation loss [FL] and sleep quality, VF experience, and age. Methods. Prospective, cross-sectional study. Adult patients (age ≥ 18 years completing automated VF testing were invited to participate. Baseline participant characteristics were obtained, and all participants were asked to complete the Pittsburgh Sleep Quality Index (PSQI questionnaire. Nonparametric Spearman correlations and logistical regression models were performed. Results. 63 patients were enrolled. Lower PSQI score was correlated with higher percentage (% FL in the right eye (p=0.03. Fewer prior VF was significantly correlated with higher %FP in the right eye (p=0.008. Older age was significantly correlated with higher %FN in the left eye (p=0.01. Greater mean deviation (MD and pattern standard deviation (PSD were strongly correlated with higher %FN in the right (p=0.02 and 0.002, resp. and left eyes (p=0.01 and 0.02, resp.. Conclusion. In this prospective, cross-sectional study, worse MD and PSD are strongly correlated with increased FN in both eyes. Increased FN in the left eye associated with older age might be attributable to test fatigue. Worse sleep quality is associated with decreased FL in the right eye.

  2. Reliability studies of a high-power proton accelerator for accelerator-driven system applications for nuclear waste transmutation

    Energy Technology Data Exchange (ETDEWEB)

    Burgazzi, Luciano [ENEA-Centro Ricerche ' Ezio Clementel' , Advanced Physics Technology Division, Via Martiri di Monte Sole, 4, 40129 Bologna (Italy)]. E-mail: burgazzi@bologna.enea.it; Pierini, Paolo [INFN-Sezione di Milano, Laboratorio Acceleratori e Superconduttivita Applicata, Via Fratelli Cervi 201, I-20090 Segrate (MI) (Italy)

    2007-04-15

    The main effort of the present study is to analyze the availability and reliability of a high-performance linac (linear accelerator) conceived for Accelerator-Driven Systems (ADS) purpose and to suggest recommendations, in order both to meet the high operability goals and to satisfy the safety requirements dictated by the reactor system. Reliability Block Diagrams (RBD) approach has been considered for system modelling, according to the present level of definition of the design: component failure modes are assessed in terms of Mean Time Between Failure (MTBF) and Mean Time To Repair (MTTR), reliability and availability figures are derived, applying the current reliability algorithms. The lack of a well-established component database has been pointed out as the main issue related to the accelerator reliability assessment. The results, affected by the conservative character of the study, show a high margin for the improvement in terms of accelerator reliability and availability figures prediction. The paper outlines the viable path towards the accelerator reliability and availability enhancement process and delineates the most proper strategies. The improvement in the reliability characteristics along this path is shown as well.

  3. Reliability studies of a high-power proton accelerator for accelerator-driven system applications for nuclear waste transmutation

    International Nuclear Information System (INIS)

    Burgazzi, Luciano; Pierini, Paolo

    2007-01-01

    The main effort of the present study is to analyze the availability and reliability of a high-performance linac (linear accelerator) conceived for Accelerator-Driven Systems (ADS) purpose and to suggest recommendations, in order both to meet the high operability goals and to satisfy the safety requirements dictated by the reactor system. Reliability Block Diagrams (RBD) approach has been considered for system modelling, according to the present level of definition of the design: component failure modes are assessed in terms of Mean Time Between Failure (MTBF) and Mean Time To Repair (MTTR), reliability and availability figures are derived, applying the current reliability algorithms. The lack of a well-established component database has been pointed out as the main issue related to the accelerator reliability assessment. The results, affected by the conservative character of the study, show a high margin for the improvement in terms of accelerator reliability and availability figures prediction. The paper outlines the viable path towards the accelerator reliability and availability enhancement process and delineates the most proper strategies. The improvement in the reliability characteristics along this path is shown as well

  4. Reliability of tonosafe disposable tonometer prisms: clinical implications from the Veterans Affairs Boston Healthcare System Quality Assurance Study.

    Science.gov (United States)

    Thomas, V; Daly, M K; Cakiner-Egilmez, T; Baker, E

    2011-05-01

    Given the Veterans Affairs Boston Healthcare System's recent introduction of single-use Tonosafe disposable tonometer prisms as an alternative to Goldmann applanation tonometers (GATs), this study had two aims: to conduct a large-scale quality assurance trial to assess the reliability of intraocular pressure (IOP) measurements of the Tonosafe disposable tonometer compared with GAT, particularly at extremes of pressure; to evaluate the suitability of Tonosafe disposable tonometer prisms as an acceptable substitute for GATs and for clinic-wide implementation in an academic tertiary referral setting. Ophthalmology resident physicians measured the IOPs of patients in general and specialty eye clinics with the Tonosafe disposable tonometer and GAT. Tonosafe test-retest reliability data were also collected. A retrospective review of patient charts and data analysis were performed to determine the reliability of measurements. The IOPs of 652 eyes (326 patients) were measured with both GAT and Tonosafe, with a range of 3-34 mm Hg. Linear regression analysis showed R=0.93, slope=0.91, both of which supported the proposed hypothesis, and the y-intercept=-1.05 was significantly different from the hypothesized value. The Tonosafe test-retest repeatability (40 eyes of 40 patients), r=0.977, was very high, which was further supported by linear regression slope=0.993, y-intercept=0.118, and a Tonosafe repeatability coefficient of 2.06, similar to GAT repeatability. The IOP measurements by Tonosafe disposable prisms correlated closely with Goldmann measurements, with similar repeated measurement variability to GAT. This suggests that the Tonosafe is an acceptable substitute for GAT to measure IOP in ophthalmology clinic settings.

  5. Reliability of an e-PRO Tool of EORTC QLQ-C30 for Measurement of Health-Related Quality of Life in Patients With Breast Cancer: Prospective Randomized Trial.

    Science.gov (United States)

    Wallwiener, Markus; Matthies, Lina; Simoes, Elisabeth; Keilmann, Lucia; Hartkopf, Andreas D; Sokolov, Alexander N; Walter, Christina B; Sickenberger, Nina; Wallwiener, Stephanie; Feisst, Manuel; Gass, Paul; Fasching, Peter A; Lux, Michael P; Wallwiener, Diethelm; Taran, Florin-Andrei; Rom, Joachim; Schneeweiss, Andreas; Graf, Joachim; Brucker, Sara Y

    2017-09-14

    Breast cancer represents the most common malignant disease in women worldwide. As currently systematic palliative treatment only has a limited effect on survival rates, the concept of health-related quality of life (HRQoL) is gaining more and more importance in the therapy setting of metastatic breast cancer. One of the major patient-reported outcomes (PROs) for measuring HRQoL in patients with breast cancer is provided by the European Organization for Research and Treatment of Cancer (EORTC). Currently, paper-based surveys still predominate, as only a few reliable and validated electronic-based questionnaires are available. Facing the possibilities associated with evolving digitalization in medicine, validation of electronic versions of well-established PRO is essential in order to contribute to comprehensive and holistic oncological care and to ensure high quality in cancer research. The aim of this study was to analyze the reliability of a tablet-based measuring application for EORTC QLQ-C30 in German language in patients with adjuvant and (curative) metastatic breast cancer. Paper- and tablet-based questionnaires were completed by a total of 106 female patients with adjuvant and metastatic breast cancer recruited as part of the e-PROCOM study. All patients were required to complete the electronic- (e-PRO) and paper-based versions of the HRQoL EORTC QLQ-C30 questionnaire. A frequency analysis was performed to determine descriptive sociodemographic characteristics. Both dimensions of reliability (parallel forms reliability [Wilcoxon test] and test of internal consistency [Spearman rho and agreement rates for single items, Pearson correlation and Kendall tau for each scale]) were analyzed. High correlations were shown for both dimensions of reliability (parallel forms reliability and internal consistency) in the patient's response behavior between paper- and electronic-based questionnaires. Regarding the test of parallel forms reliability, no significant

  6. A novel high reliability CMOS SRAM cell

    Energy Technology Data Exchange (ETDEWEB)

    Xie Chengmin; Wang Zhongfang; Wu Longsheng; Liu Youbao, E-mail: hglnew@sina.com [Computer Research and Design Department, Xi' an Microelectronic Technique Institutes, Xi' an 710054 (China)

    2011-07-15

    A novel 8T single-event-upset (SEU) hardened and high static noise margin (SNM) SRAM cell is proposed. By adding one transistor paralleled with each access transistor, the drive capability of pull-up PMOS is greater than that of the conventional cell and the read access transistors are weaker than that of the conventional cell. So the hold, read SNM and critical charge increase greatly. The simulation results show that the critical charge is almost three times larger than that of the conventional 6T cell by appropriately sizing the pull-up transistors. The hold and read SNM of the new cell increase by 72% and 141.7%, respectively, compared to the 6T design, but it has a 54% area overhead and read performance penalty. According to these features, this novel cell suits high reliability applications, such as aerospace and military. (semiconductor integrated circuits)

  7. A novel high reliability CMOS SRAM cell

    International Nuclear Information System (INIS)

    Xie Chengmin; Wang Zhongfang; Wu Longsheng; Liu Youbao

    2011-01-01

    A novel 8T single-event-upset (SEU) hardened and high static noise margin (SNM) SRAM cell is proposed. By adding one transistor paralleled with each access transistor, the drive capability of pull-up PMOS is greater than that of the conventional cell and the read access transistors are weaker than that of the conventional cell. So the hold, read SNM and critical charge increase greatly. The simulation results show that the critical charge is almost three times larger than that of the conventional 6T cell by appropriately sizing the pull-up transistors. The hold and read SNM of the new cell increase by 72% and 141.7%, respectively, compared to the 6T design, but it has a 54% area overhead and read performance penalty. According to these features, this novel cell suits high reliability applications, such as aerospace and military. (semiconductor integrated circuits)

  8. Design of piezoelectric transducer layer with electromagnetic shielding and high connection reliability

    Science.gov (United States)

    Qiu, Lei; Yuan, Shenfang; Shi, Xiaoling; Huang, Tianxiang

    2012-07-01

    Piezoelectric transducer (PZT) and Lamb wave based structural health monitoring (SHM) method have been widely studied for on-line SHM of high-performance structures. To monitor large-scale structures, a dense PZTs array is required. In order to improve the placement efficiency and reduce the wire burden of the PZTs array, the concept of the piezoelectric transducers layer (PSL) was proposed. The PSL consists of PZTs, a flexible interlayer with printed wires and signal input/output interface. For on-line SHM on real aircraft structures, there are two main issues on electromagnetic interference and connection reliability of the PSL. To address the issues, an electromagnetic shielding design method of the PSL to reduce spatial electromagnetic noise and crosstalk is proposed and a combined welding-cementation process based connection reliability design method is proposed to enhance the connection reliability between the PZTs and the flexible interlayer. Two experiments on electromagnetic interference suppression are performed to validate the shielding design of the PSL. The experimental results show that the amplitudes of the spatial electromagnetic noise and crosstalk output from the shielded PSL developed by this paper are - 15 dB and - 25 dB lower than those of the ordinary PSL, respectively. Other two experiments on temperature durability ( - 55 °C-80 °C ) and strength durability (160-1600μɛ, one million load cycles) are applied to the PSL to validate the connection reliability. The low repeatability errors (less than 3% and less than 5%, respectively) indicate that the developed PSL is of high connection reliability and long fatigue life.

  9. Patient Assessment of Constipation Quality of Life Questionnaire: Translation, Cultural Adaptation, Reliability, and Validity of the Persian Version.

    Science.gov (United States)

    Nikjooy, Afsaneh; Jafari, Hassan; Saba, Maryam A; Ebrahimi, Naghmeh; Mirzaei, Rezvan

    2018-05-01

    The Patient Assessment of Constipation Quality of Life (PAC-QOL) questionnaire is the most validated and the most specific tool for measuring the quality of life of patients with constipation. Over 120 million people live in countries whose official language is Persian. There is no reported Persian version of the PAC-QOL questionnaire yet. The aim of this study was to translate and culturally adapt the PAC-QOL questionnaire and to assess its reliability and validity among Persian patients with chronic constipation. Following the translation and cultural adaptation of the PAC-QOL questionnaire to Persian, 100 patients (mean±SD age=40.51±13.67) with constipation were recruited for validity measurement and 20 patients were re-examined for reliability. Content validity was assessed based on the opinions of an expert committee and the floor/ceiling effect. Construct validity was evaluated according to the hypothesis test. The SF-36 questionnaire was used for concurrent criterion validity, intra-class correlation coefficient for reliability, and Cronbach's alpha for internal consistency. The content validity of the PAC-QOL questionnaire was proven, and there was no floor/ceiling effect. Construct validity also was confirmed based on the hypothesis test. The overall Cronbach's alpha of the PAC-QOL questionnaire was 0.92 (range=0.72-0.92), and the overall intra-class correlation coefficient of the questionnaire was 0.88 (range=0.69-0.87). The correlation between the SF-36 and PAC-QOL questionnaires was moderate. The Persian version of the PAC-QOL questionnaire demonstrated good validity and reliability properties in chronic constipation. Accordingly, Persian researchers and clinicians can benefit from this questionnaire in further research and assessment of treatment outcomes.

  10. Feasibility, reliability, and validity of the Japanese version of the Postoperative Quality of Recovery Scale: a first pilot study.

    Science.gov (United States)

    Naito, Yusuke; Tanaka, Yuu; Sasaoka, Noriyuki; Iwata, Toshio; Fujimoto, Yuko; Okamoto, Nozomi; Inoue, Satoki; Kawaguchi, Masahiko

    2015-06-01

    The Postoperative Quality of Recovery Scale (PQRS) is a multi-domain tracking scale to assess recovery after surgery. The PQRS is used in seven countries and five languages; however, the Japanese version of the PQRS (PQRSj) has not been established. We therefore translated the PQRS into Japanese, and examined the feasibility, reliability and validity of the PQRSj. The time taken to complete the test was measured to assess feasibility. Cronbach's alpha was calculated to assess reliability. The Mini Mental State Examination (MMSE) and the Japanese version of the Quality of Recovery Scale 40 (QoR-40 J) were performed for comparison with the PQRSj (validity). Fifty-one patients were enrolled in the study. The mean completion time was 3.9 min for baseline (feasibility). Cronbach's alpha was between 0.40 and 0.94 in each domain (reliability). A relationship was shown between cognitive domain and MMSE at baseline (r = 0.65, P < 0.01); however, no relationship was found between the other domains and the MMSE and QoR-40 J. Ceiling effects were observed in 78% of the questions. These results indicate that the PQRSj can be used to assess recovery after surgery, although it may be better to revise some of the questions to improve the validity of the PQRSj.

  11. Assessing software quality at each step of its life-cycle to enhance reliability of control systems

    International Nuclear Information System (INIS)

    Hardion, V.; Buteau, A.; Leclercq, N.; Abeille, G.; Pierre-Joseph, Z.; Le, S.

    2012-01-01

    A distributed software control system aims to enhance the upgrade ability and reliability by sharing responsibility between several components. The disadvantage is that it makes it harder to detect problems on a significant number of modules. With Kaizen in mind we have chosen to continuously invest in automation to obtain a complete overview of software quality despite the growth of legacy code. The development process has already been mastered by staging each life-cycle step thanks to a continuous integration server based on JENKINS and MAVEN. We enhanced this process, focusing on 3 objectives: Automatic Test, Static Code Analysis and Post-Mortem Supervision. Now, the build process automatically includes a test section to detect regressions, incorrect behaviour and integration incompatibility. The in-house TANGOUNIT project satisfies the difficulties of testing distributed components such as Tango Devices. In the next step, the programming code has to pass a complete code quality check-up. The SONAR quality server has been integrated in the process, to collect each static code analysis and display the hot topics on summary web pages. Finally, the integration of Google BREAKPAD in every TANGO Devices gives us essential statistics from crash reports and enables us to replay the crash scenarios at any time. We have already gained greater visibility on current developments. Some concrete results will be presented including reliability enhancement, better management of subcontracted software development, quicker adoption of coding standards by new developers and understanding of impacts when moving to a new technology. (authors)

  12. Scalable shear-exfoliation of high-quality phosphorene nanoflakes with reliable electrochemical cycleability in nano batteries

    International Nuclear Information System (INIS)

    Xu, Feng; Min, Huihua; Zhu, Chongyang; Xia, Weiwei; Li, Zhengrui; Li, Shengli; Yu, Kaihao; Sun, Litao; Ge, Binghui; Chen, Jing; Cui, Yiping; Nathan, Arokia; Xin, Linhuo L; Ma, Hongyu; Wu, Lijun; Zhu, Yimei

    2016-01-01

    Atomically thin black phosphorus (called phosphorene) holds great promise as an alternative to graphene and other two-dimensional transition-metal dichalcogenides as an anode material for lithium-ion batteries (LIBs). However, bulk black phosphorus (BP) suffers from rapid capacity fading and poor rechargeable performance. This work reports for the first time the use of in situ transmission electron microscopy (TEM) to construct nanoscale phosphorene LIBs. This enables direct visualization of the mechanisms underlying capacity fading in thick multilayer phosphorene through real-time capture of delithiation-induced structural decomposition, which serves to reduce electrical conductivity thus causing irreversibility of the lithiated phases. We further demonstrate that few-layer-thick phosphorene successfully circumvents the structural decomposition and holds superior structural restorability, even when subject to multi-cycle lithiation/delithiation processes and concomitant huge volume expansion. This finding provides breakthrough insights into thickness-dependent lithium diffusion kinetics in phosphorene. More importantly, a scalable liquid-phase shear exfoliation route has been developed to produce high-quality ultrathin phosphorene using simple means such as a high-speed shear mixer or even a household kitchen blender with the shear rate threshold of ∼1.25 × 10 4 s −1 . The results reported here will pave the way for industrial-scale applications of rechargeable phosphorene LIBs. (paper)

  13. Risk-based methods for reliability investments in electric power distribution systems

    Energy Technology Data Exchange (ETDEWEB)

    Alvehag, Karin

    2011-07-01

    Society relies more and more on a continuous supply of electricity. However, while under investments in reliability lead to an unacceptable number of power interruptions, over investments result in too high costs for society. To give incentives for a socio economically optimal level of reliability, quality regulations have been adopted in many European countries. These quality regulations imply new financial risks for the distribution system operator (DSO) since poor reliability can reduce the allowed revenue for the DSO and compensation may have to be paid to affected customers. This thesis develops a method for evaluating the incentives for reliability investments implied by different quality regulation designs. The method can be used to investigate whether socio economically beneficial projects are also beneficial for a profit-maximizing DSO subject to a particular quality regulation design. To investigate which reinvestment projects are preferable for society and a DSO, risk-based methods are developed. With these methods, the probability of power interruptions and the consequences of these can be simulated. The consequences of interruptions for the DSO will to a large extent depend on the quality regulation. The consequences for the customers, and hence also society, will depend on factors such as the interruption duration and time of occurrence. The proposed risk-based methods consider extreme outage events in the risk assessments by incorporating the impact of severe weather, estimating the full probability distribution of the total reliability cost, and formulating a risk-averse strategy. Results from case studies performed show that quality regulation design has a significant impact on reinvestment project profitability for a DSO. In order to adequately capture the financial risk that the DSO is exposed to, detailed riskbased methods, such as the ones developed in this thesis, are needed. Furthermore, when making investment decisions, a risk

  14. Technology Improvement for the High Reliability LM-2F Launch Vehicle

    Institute of Scientific and Technical Information of China (English)

    QIN Tong; RONG Yi; ZHENG Liwei; ZHANG Zhi

    2017-01-01

    The Long March 2F (LM-2F) launch vehicle,the only launch vehicle designed for manned space flight in China,successfully launched the Tiangong 2 space laboratory and the Shenzhou ll manned spaceship into orbits in 2016 respectively.In this study,it introduces the technological improvements for enhancing the reliability of the LM-2F launch vehicle in the aspects of general technology,control system,manufacture and ground support system.The LM2F launch vehicle will continue to provide more contributions to the Chinese Space Station Project with its high reliability and 100% success rate.

  15. Toward reliable and repeatable automated STEM-EDS metrology with high throughput

    Science.gov (United States)

    Zhong, Zhenxin; Donald, Jason; Dutrow, Gavin; Roller, Justin; Ugurlu, Ozan; Verheijen, Martin; Bidiuk, Oleksii

    2018-03-01

    New materials and designs in complex 3D architectures in logic and memory devices have raised complexity in S/TEM metrology. In this paper, we report about a newly developed, automated, scanning transmission electron microscopy (STEM) based, energy dispersive X-ray spectroscopy (STEM-EDS) metrology method that addresses these challenges. Different methodologies toward repeatable and efficient, automated STEM-EDS metrology with high throughput are presented: we introduce the best known auto-EDS acquisition and quantification methods for robust and reliable metrology and present how electron exposure dose impacts the EDS metrology reproducibility, either due to poor signalto-noise ratio (SNR) at low dose or due to sample modifications at high dose conditions. Finally, we discuss the limitations of the STEM-EDS metrology technique and propose strategies to optimize the process both in terms of throughput and metrology reliability.

  16. A clinical assessment tool used for physiotherapy students--is it reliable?

    Science.gov (United States)

    Lewis, Lucy K; Stiller, Kathy; Hardy, Frances

    2008-01-01

    Educational institutions providing professional programs such as physiotherapy must provide high-quality student assessment procedures. To ensure that assessment is consistent, assessment tools should have an acceptable level of reliability. There is a paucity of research evaluating the reliability of clinical assessment tools used for physiotherapy students. This study evaluated the inter- and intrarater reliability of an assessment tool used for physiotherapy students during a clinical placement. Five clinical educators and one academic participated in the study. Each rater independently marked 22 student written assessments that had been completed by students after viewing a videotaped patient physiotherapy assessment. The raters repeated the marking process 7 weeks later, with the assessments provided in a randomised order. The interrater reliability (Intraclass Correlation Coefficient) for the total scores was 0.32, representing a poor level of reliability. A high level of intrarater reliability (percentage agreement) was found for the clinical educators, with a difference in section scores of one mark or less on 93.4% of occasions. Further research should be undertaken to reevaluate the reliability of this clinical assessment tool following training. The reliability of clinical assessment tools used in other areas of physiotherapy education should be formally measured rather than assumed.

  17. Study of evaluation techniques of software safety and reliability in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Youn, Cheong; Baek, Y. W.; Kim, H. C.; Park, N. J.; Shin, C. Y. [Chungnam National Univ., Taejon (Korea, Republic of)

    1999-04-15

    Software system development process and software quality assurance activities are examined in this study. Especially software safety and reliability requirements in nuclear power plant are investigated. For this purpose methodologies and tools which can be applied to software analysis, design, implementation, testing, maintenance step are evaluated. Necessary tasks for each step are investigated. Duty, input, and detailed activity for each task are defined to establish development process of high quality software system. This means applying basic concepts of software engineering and principles of system development. This study establish a guideline that can assure software safety and reliability requirements in digitalized nuclear plant systems and can be used as a guidebook of software development process to assure software quality many software development organization.

  18. System principles, mathematical models and methods to ensure high reliability of safety systems

    Science.gov (United States)

    Zaslavskyi, V.

    2017-04-01

    Modern safety and security systems are composed of a large number of various components designed for detection, localization, tracking, collecting, and processing of information from the systems of monitoring, telemetry, control, etc. They are required to be highly reliable in a view to correctly perform data aggregation, processing and analysis for subsequent decision making support. On design and construction phases of the manufacturing of such systems a various types of components (elements, devices, and subsystems) are considered and used to ensure high reliability of signals detection, noise isolation, and erroneous commands reduction. When generating design solutions for highly reliable systems a number of restrictions and conditions such as types of components and various constrains on resources should be considered. Various types of components perform identical functions; however, they are implemented using diverse principles, approaches and have distinct technical and economic indicators such as cost or power consumption. The systematic use of different component types increases the probability of tasks performing and eliminates the common cause failure. We consider type-variety principle as an engineering principle of system analysis, mathematical models based on this principle, and algorithms for solving optimization problems of highly reliable safety and security systems design. Mathematical models are formalized in a class of two-level discrete optimization problems of large dimension. The proposed approach, mathematical models, algorithms can be used for problem solving of optimal redundancy on the basis of a variety of methods and control devices for fault and defects detection in technical systems, telecommunication networks, and energy systems.

  19. Examining Design and Inter-Rater Reliability of a Rubric Measuring Research Quality across Multiple Disciplines

    Directory of Open Access Journals (Sweden)

    Marilee J. Bresciani

    2009-05-01

    Full Text Available The paper presents a rubric to help evaluate the quality of research projects. The rubric was applied in a competition across a variety of disciplines during a two-day research symposium at one institution in the southwest region of the United States of America. It was collaboratively designed by a faculty committee at the institution and was administered to 204 undergraduate, master, and doctoral oral presentations by approximately 167 different evaluators. No training or norming of the rubric was given to 147 of the evaluators prior to the competition. The findings of the inter-rater reliability analysis reveal substantial agreement among the judges, which contradicts literature describing the fact that formal norming must occur prior to seeing substantial levels of inter-rater reliability. By presenting the rubric along with the methodology used in its design and evaluation, it is hoped that others will find this to be a useful tool for evaluating documents and for teaching research methods.

  20. Design of piezoelectric transducer layer with electromagnetic shielding and high connection reliability

    International Nuclear Information System (INIS)

    Qiu, Lei; Yuan, Shenfang; Shi, Xiaoling; Huang, Tianxiang

    2012-01-01

    Piezoelectric transducer (PZT) and Lamb wave based structural health monitoring (SHM) method have been widely studied for on-line SHM of high-performance structures. To monitor large-scale structures, a dense PZTs array is required. In order to improve the placement efficiency and reduce the wire burden of the PZTs array, the concept of the piezoelectric transducers layer (PSL) was proposed. The PSL consists of PZTs, a flexible interlayer with printed wires and signal input/output interface. For on-line SHM on real aircraft structures, there are two main issues on electromagnetic interference and connection reliability of the PSL. To address the issues, an electromagnetic shielding design method of the PSL to reduce spatial electromagnetic noise and crosstalk is proposed and a combined welding–cementation process based connection reliability design method is proposed to enhance the connection reliability between the PZTs and the flexible interlayer. Two experiments on electromagnetic interference suppression are performed to validate the shielding design of the PSL. The experimental results show that the amplitudes of the spatial electromagnetic noise and crosstalk output from the shielded PSL developed by this paper are − 15 dB and − 25 dB lower than those of the ordinary PSL, respectively. Other two experiments on temperature durability ( − 55 °C–80 °C ) and strength durability (160–1600με, one million load cycles) are applied to the PSL to validate the connection reliability. The low repeatability errors (less than 3% and less than 5%, respectively) indicate that the developed PSL is of high connection reliability and long fatigue life. (paper)

  1. Insightful practice: a reliable measure for medical revalidation

    Science.gov (United States)

    Guthrie, Bruce; Sullivan, Frank M; Mercer, Stewart W; Russell, Andrew; Bruce, David A

    2012-01-01

    Background Medical revalidation decisions need to be reliable if they are to reassure on the quality and safety of professional practice. This study tested an innovative method in which general practitioners (GPs) were assessed on their reflection and response to a set of externally specified feedback. Setting and participants 60 GPs and 12 GP appraisers in the Tayside region of Scotland, UK. Methods A feedback dataset was specified as (1) GP-specific data collected by GPs themselves (patient and colleague opinion; open book self-evaluated knowledge test; complaints) and (2) Externally collected practice-level data provided to GPs (clinical quality and prescribing safety). GPs' perceptions of whether the feedback covered UK General Medical Council specified attributes of a ‘good doctor’ were examined using a mapping exercise. GPs' professionalism was examined in terms of appraiser assessment of GPs' level of insightful practice, defined as: engagement with, insight into and appropriate action on feedback data. The reliability of assessment of insightful practice and subsequent recommendations on GPs' revalidation by face-to-face and anonymous assessors were investigated using Generalisability G-theory. Main outcome measures Coverage of General Medical Council attributes by specified feedback and reliability of assessor recommendations on doctors' suitability for revalidation. Results Face-to-face assessment proved unreliable. Anonymous global assessment by three appraisers of insightful practice was highly reliable (G=0.85), as were revalidation decisions using four anonymous assessors (G=0.83). Conclusions Unlike face-to-face appraisal, anonymous assessment of insightful practice offers a valid and reliable method to decide GP revalidation. Further validity studies are needed. PMID:22653078

  2. Spectral reflectance is a reliable water-quality estimator for small, highly turbid wetlands

    Czech Academy of Sciences Publication Activity Database

    Vinciková, H.; Hanuš, Jan; Pechar, L.

    2015-01-01

    Roč. 23, č. 5 (2015), s. 933-946 ISSN 0923-4861 R&D Projects: GA MŠk(CZ) LM2010007; GA MŠk 2B06068 Institutional support: RVO:67179843 Keywords : remote sensing * water quality * hyperspectral reflectance * turbid inland waters * chlorophyll * TSS Subject RIV: DA - Hydrology ; Limnology Impact factor: 1.407, year: 2015

  3. 76 FR 72203 - Voltage Coordination on High Voltage Grids; Notice of Reliability Workshop Agenda

    Science.gov (United States)

    2011-11-22

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. AD12-5-000] Voltage Coordination on High Voltage Grids; Notice of Reliability Workshop Agenda As announced in the Notice of Staff..., from 9 a.m. to 4:30 p.m. to explore the interaction between voltage control, reliability, and economic...

  4. High Reliability Prototype Quadrupole for the Next Linear Collider

    International Nuclear Information System (INIS)

    Spencer, Cherrill M

    2001-01-01

    The Next Linear Collider (NLC) will require over 5600 magnets, each of which must be highly reliable and/or quickly repairable in order that the NLC reach its 85% overall availability goal. A multidiscipline engineering team was assembled at SLAC to develop a more reliable electromagnet design than historically had been achieved at SLAC. This team carried out a Failure Mode and Effects Analysis (FMEA) on a standard SLAC quadrupole magnet system. They overcame a number of longstanding design prejudices, producing 10 major design changes. This paper describes how a prototype magnet was constructed and the extensive testing carried out on it to prove full functionality with an improvement in reliability. The magnet's fabrication cost will be compared to the cost of a magnet with the same requirements made in the historic SLAC way. The NLC will use over 1600 of these 12.7 mm bore quadrupoles with a range of integrated strengths from 0.6 to 132 Tesla, a maximum gradient of 135 Tesla per meter, an adjustment range of 0 to -20% and core lengths from 324 mm to 972 mm. The magnetic center must remain stable to within 1 micron during the 20% adjustment. A magnetic measurement set-up has been developed that can measure sub-micron shifts of a magnetic center. The prototype satisfied the center shift requirement over the full range of integrated strengths

  5. Using Rasch Analysis to Evaluate the Reliability and Validity of the Swallowing Quality of Life Questionnaire: An Item Response Theory Approach.

    Science.gov (United States)

    Cordier, Reinie; Speyer, Renée; Schindler, Antonio; Michou, Emilia; Heijnen, Bas Joris; Baijens, Laura; Karaduman, Ayşe; Swan, Katina; Clavé, Pere; Joosten, Annette Veronica

    2018-02-01

    The Swallowing Quality of Life questionnaire (SWAL-QOL) is widely used clinically and in research to evaluate quality of life related to swallowing difficulties. It has been described as a valid and reliable tool, but was developed and tested using classic test theory. This study describes the reliability and validity of the SWAL-QOL using item response theory (IRT; Rasch analysis). SWAL-QOL data were gathered from 507 participants at risk of oropharyngeal dysphagia (OD) across four European countries. OD was confirmed in 75.7% of participants via videofluoroscopy and/or fiberoptic endoscopic evaluation, or a clinical diagnosis based on meeting selected criteria. Patients with esophageal dysphagia were excluded. Data were analysed using Rasch analysis. Item and person reliability was good for all the items combined. However, person reliability was poor for 8 subscales and item reliability was poor for one subscale. Eight subscales exhibited poor person separation and two exhibited poor item separation. Overall item and person fit statistics were acceptable. However, at an individual item fit level results indicated unpredictable item responses for 28 items, and item redundancy for 10 items. The item-person dimensionality map confirmed these findings. Results from the overall Rasch model fit and Principal Component Analysis were suggestive of a second dimension. For all the items combined, none of the item categories were 'category', 'threshold' or 'step' disordered; however, all subscales demonstrated category disordered functioning. Findings suggest an urgent need to further investigate the underlying structure of the SWAL-QOL and its psychometric characteristics using IRT.

  6. The EORTC Core Quality of Life questionnaire (QLQ-C30): validity and reliability when analysed with patients treated with palliative radiotherapy

    International Nuclear Information System (INIS)

    Kaasa, S.; Aaronson, N.

    1995-01-01

    The EORTC Core Quality of Life questionnaire (EORTC QLQ-C30) is designed to measure cancer patients' physical, psychological and social functions. The questionnaire is composed of multi-item scales and single items. 247 patients completed the EORTC QLQ-C30 before palliative radiotherapy and 181 after palliative radiotherapy. The questionnaire was well accepted with a high completion rate in the present patient population consisting of advanced cancer patients with short life expectancy. In addition, the questionnaire was found to be useful to detect the effect of palliative radiotherapy over time. The scale reliability was excellent for all scales except the role functioning scale. Excellent criterion validity was found for the emotional functioning scale where it was correlated with GHQ-20. Performance of the questionnaire was improved after the second evaluation as compared with the first. The present study shows that the EORTC-QLQ-C30 is found to be practical and valid in measuring quality of life in patients with advanced disease. (author)

  7. Reliable detection of fluence anomalies in EPID-based IMRT pretreatment quality assurance using pixel intensity deviations

    International Nuclear Information System (INIS)

    Gordon, J. J.; Gardner, J. K.; Wang, S.; Siebers, J. V.

    2012-01-01

    Purpose: This work uses repeat images of intensity modulated radiation therapy (IMRT) fields to quantify fluence anomalies (i.e., delivery errors) that can be reliably detected in electronic portal images used for IMRT pretreatment quality assurance. Methods: Repeat images of 11 clinical IMRT fields are acquired on a Varian Trilogy linear accelerator at energies of 6 MV and 18 MV. Acquired images are corrected for output variations and registered to minimize the impact of linear accelerator and electronic portal imaging device (EPID) positioning deviations. Detection studies are performed in which rectangular anomalies of various sizes are inserted into the images. The performance of detection strategies based on pixel intensity deviations (PIDs) and gamma indices is evaluated using receiver operating characteristic analysis. Results: Residual differences between registered images are due to interfraction positional deviations of jaws and multileaf collimator leaves, plus imager noise. Positional deviations produce large intensity differences that degrade anomaly detection. Gradient effects are suppressed in PIDs using gradient scaling. Background noise is suppressed using median filtering. In the majority of images, PID-based detection strategies can reliably detect fluence anomalies of ≥5% in ∼1 mm 2 areas and ≥2% in ∼20 mm 2 areas. Conclusions: The ability to detect small dose differences (≤2%) depends strongly on the level of background noise. This in turn depends on the accuracy of image registration, the quality of the reference image, and field properties. The longer term aim of this work is to develop accurate and reliable methods of detecting IMRT delivery errors and variations. The ability to resolve small anomalies will allow the accuracy of advanced treatment techniques, such as image guided, adaptive, and arc therapies, to be quantified.

  8. A criterion of the performance of thermometric systems of high metrological reliability

    International Nuclear Information System (INIS)

    Sal'nikov, N.L.; Filimonov, E.V.

    1995-01-01

    Monitoring temperature regimes is an important part of ensuring the operational safety of a nuclear power plant. Therefore, high standards are imposed upon the reliability of the primary information on the heat field of the object obtained from different sensors, and it is urgent to develop methods of evaluating the metrological reliability of these sensors. THe main sources of thermometric information at nuclear power plants are contact temperature sensors, the most widely used of these being thermoelectric converters (TEC) and thermal resistance converters (TRC)

  9. Features of high-speed and strength qualities development in young biathlonists aged 14–15 in the preparatory period

    Directory of Open Access Journals (Sweden)

    Artem Burla

    2015-04-01

    Full Text Available Purpose: to substantiate a methodology of high-speed and strength qualities development of young biathlonists aged 14–15 during the preparatory period. Material and Methods: young biathlonists aged 14–15 from control and experimental groups took part in the research. There were 12 athletes in each group. Pedagogical methods and methods of mathematical statistics were used in the work. Pedagogical methods of researches were used for level definition of high-speed and strength qualities development of young biathlonists. Results: reliable increase of motive qualities and polydynamometry results testing of young biathlonists from the experimental group due to implementation of the experimental methodology in the preparatory period is established. Conclusions: application of the developed complexes in the preparatory period in the experimental group of young biathlonists aged 14–15 allows to raise indices of motive qualities and polydynamometry testing statistically significantly.

  10. Assessment of bird populations in a high quality savanna/woodland: a banding approach

    Science.gov (United States)

    Wilmore, Sandra L.; Glowacki, Gary A.; Grundel, Ralph

    2005-01-01

    Between 1999 and 2004, Save the Dunes Conservation Fund's Miller Woods Bird Banding Program monitored migrating and breeding bird populations within a high quality black oak, dry-mesic sand savanna/woodland with ridge and swale topography. The objectives of this program were to collect consistent and reliable demographic and abundance data on the bird populations, to investigate long-term population trends, and to contribute to improved land management decisions at regional and national scales. The technique employed involved capturing birds in mist nets that were deployed for set periods of time at 17 net sites in two banding areas in Miller Woods.

  11. Translation, reliability, and clinical utility of the Melbourne Assessment 2.

    Science.gov (United States)

    Gerber, Corinna N; Plebani, Anael; Labruyère, Rob

    2017-10-12

    The aims were to (i) provide a German translation of the Melbourne Assessment 2 (MA2), a quantitative test to measure unilateral upper limb function in children with neurological disabilities and (ii) to evaluate its reliability and aspects of clinical utility. After its translation into German and approval of the back translation by the original authors, the MA2 was performed and videotaped twice with 30 children with neuromotor disorders. For each participant, two raters scored the video of the first test for inter-rater reliability. To determine test-retest reliability, one rater additionally scored the video of the second test while the other rater repeated the scoring of the first video to evaluate intra-rater reliability. Time needed for rater training, test administration, and scoring was recorded. The four subscale scores showed excellent intra-, inter-rater, and test-retest reliability with intraclass correlation coefficients of 0.90-1.00 (95%-confidence intervals 0.78-1.00). Score items revealed substantial to almost perfect intra-rater reliability (weighted kappa k w  = 0.66-1.00) for the more affected side. Score item inter-rater and test-retest reliability of the same extremity were, with one exception, moderate to almost perfect (k w  = 0.42-0.97; k w  = 0.40-0.89). Furthermore, the MA2 was feasible and acceptable for patients and clinicians. The MA2 showed excellent subscale and moderate to almost perfect score item reliability. Implications for Rehabilitation There is a lack of high-quality studies about psychometric properties of upper limb measurement tools in the neuropediatric population. The Melbourne Assessment 2 is a promising tool for reliable measurement of unilateral upper limb movement quality in the neuropediatric population. The Melbourne Assessment 2 is acceptable and practicable to therapists and patients for routine use in clinical care.

  12. Space transportation main engine reliability and safety

    Science.gov (United States)

    Monk, Jan C.

    1991-01-01

    Viewgraphs are used to illustrate the reliability engineering and aerospace safety of the Space Transportation Main Engine (STME). A technology developed is called Total Quality Management (TQM). The goal is to develop a robust design. Reducing process variability produces a product with improved reliability and safety. Some engine system design characteristics are identified which improves reliability.

  13. Quality Evaluation of Potentilla fruticosa L. by High Performance Liquid Chromatography Fingerprinting Associated with Chemometric Methods.

    Science.gov (United States)

    Liu, Wei; Wang, Dongmei; Liu, Jianjun; Li, Dengwu; Yin, Dongxue

    2016-01-01

    The present study was performed to assess the quality of Potentilla fruticosa L. sampled from distinct regions of China using high performance liquid chromatography (HPLC) fingerprinting coupled with a suite of chemometric methods. For this quantitative analysis, the main active phytochemical compositions and the antioxidant activity in P. fruticosa were also investigated. Considering the high percentages and antioxidant activities of phytochemicals, P. fruticosa samples from Kangding, Sichuan were selected as the most valuable raw materials. Similarity analysis (SA) of HPLC fingerprints, hierarchical cluster analysis (HCA), principle component analysis (PCA), and discriminant analysis (DA) were further employed to provide accurate classification and quality estimates of P. fruticosa. Two principal components (PCs) were collected by PCA. PC1 separated samples from Kangding, Sichuan, capturing 57.64% of the variance, whereas PC2 contributed to further separation, capturing 18.97% of the variance. Two kinds of discriminant functions with a 100% discrimination ratio were constructed. The results strongly supported the conclusion that the eight samples from different regions were clustered into three major groups, corresponding with their morphological classification, for which HPLC analysis confirmed the considerable variation in phytochemical compositions and that P. fruticosa samples from Kangding, Sichuan were of high quality. The results of SA, HCA, PCA, and DA were in agreement and performed well for the quality assessment of P. fruticosa. Consequently, HPLC fingerprinting coupled with chemometric techniques provides a highly flexible and reliable method for the quality evaluation of traditional Chinese medicines.

  14. Quality Evaluation of Potentilla fruticosa L. by High Performance Liquid Chromatography Fingerprinting Associated with Chemometric Methods

    Science.gov (United States)

    Liu, Wei; Wang, Dongmei; Liu, Jianjun; Li, Dengwu; Yin, Dongxue

    2016-01-01

    The present study was performed to assess the quality of Potentilla fruticosa L. sampled from distinct regions of China using high performance liquid chromatography (HPLC) fingerprinting coupled with a suite of chemometric methods. For this quantitative analysis, the main active phytochemical compositions and the antioxidant activity in P. fruticosa were also investigated. Considering the high percentages and antioxidant activities of phytochemicals, P. fruticosa samples from Kangding, Sichuan were selected as the most valuable raw materials. Similarity analysis (SA) of HPLC fingerprints, hierarchical cluster analysis (HCA), principle component analysis (PCA), and discriminant analysis (DA) were further employed to provide accurate classification and quality estimates of P. fruticosa. Two principal components (PCs) were collected by PCA. PC1 separated samples from Kangding, Sichuan, capturing 57.64% of the variance, whereas PC2 contributed to further separation, capturing 18.97% of the variance. Two kinds of discriminant functions with a 100% discrimination ratio were constructed. The results strongly supported the conclusion that the eight samples from different regions were clustered into three major groups, corresponding with their morphological classification, for which HPLC analysis confirmed the considerable variation in phytochemical compositions and that P. fruticosa samples from Kangding, Sichuan were of high quality. The results of SA, HCA, PCA, and DA were in agreement and performed well for the quality assessment of P. fruticosa. Consequently, HPLC fingerprinting coupled with chemometric techniques provides a highly flexible and reliable method for the quality evaluation of traditional Chinese medicines. PMID:26890416

  15. Cross-cultural adaptation, reliability, and validity of the Turkish version of PedsQL 3.0 Arthritis Module: a quality-of-life measure for patients with juvenile idiopathic arthritis in Turkey.

    Science.gov (United States)

    Tarakci, E; Baydogan, S N; Kasapcopur, O; Dirican, A

    2013-04-01

    The aim of this study was to describe the cultural adaptation, validity, and reliability of a Turkish version of the pediatric quality-of-life inventory (PedsQL) 3.0 Arthritis Module in a population with juvenile idiopathic arthritis (JIA). A total of 169 patients with JIA and their parents were enrolled in the study. The Turkish version of the childhood health assessment questionnaire (CHAQ) was used to evaluate the validity of related domains in the PedsQL 3.0 Arthritis Module. Both the PedsQL 3.0 Arthritis Module and CHAQ were filled out by children over 8 years of age and by the parents of children 2-7 years of age. Internal reliability was poor to excellent (Cronbach's alpha coefficients 0.56-0.84 for self-reporting and 0.63-0.82 for parent reporting), and interobserver reliability varied from good to excellent (intraclass correlation coefficient (ICC) 0.79-0.91 for self-reporting and 0.80-0.88 for parent reporting) for the total scores of the PedsQL 3.0 Arthritis Module. Parent-child concordance for all scores was moderate to excellent (ICC 0.42-0.92). The PedsQL 3.0 Arthritis Module and CHAQ were highly positively correlated, with coefficients from 0.21 to 0.76, indicating concurrent validity. We demonstrated the reliability and validity of quality-of-life measurement using the Turkish version of the PedsQL 3.0 Arthritis Module in our sociocultural context. The PedsQL 3.0 Arthritis Module can be utilized as a tool for the evaluation of quality of life in patients with JIA aged 2-18 years.

  16. Analysis of quality information flows in the product creation process of high-volume consumer products

    NARCIS (Netherlands)

    Sander, P.C.; Brombacher, A.C.

    2000-01-01

    It is recently realised that Quality and Reliability are not only a function of the product but also of the organisation realising the product. In spite of this very few companies are able to translate this into their business processes. The Maturity Index on Reliability (MIR) was developed to

  17. MALDI-TOF MS for quality control of high protein content sport supplements.

    Science.gov (United States)

    De Ceglie, Cristina; Calvano, Cosima D; Zambonin, Carlo G

    2015-06-01

    High protein content sport nutritional supplements are found as powder products containing, as ingredients, amino acids and proteins with important nutritional values as milk, soy and egg proteins. An EU Food Supplements Directive (2002) requires that supplements should be safe, both in dosages and in purity. It is important, then, to develop rapid and sensitive methods to be employed for the quality control of these substances. In this work, we apply, for the first time, matrix-assisted laser desorption ionization-mass spectrometry as a fast, reproducible and sensitive method for the quality control of sport nutritional supplements based on proteins. To this aim, several commercial egg- and/or milk-based powder products have been processed by in gel or in solution digestion and analyzed in comparison to pure standard products. This strategy allowed to assess the reliability of the indications on proteins (as caseins, whey proteins and ovalbumin) declared in the label of several sport nutritional supplements. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. High Quality Data for Grid Integration Studies

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, Andrew; Draxl, Caroline; Sengupta, Manajit; Hodge, Bri-Mathias

    2017-01-22

    As variable renewable power penetration levels increase in power systems worldwide, renewable integration studies are crucial to ensure continued economic and reliable operation of the power grid. The existing electric grid infrastructure in the US in particular poses significant limitations on wind power expansion. In this presentation we will shed light on requirements for grid integration studies as far as wind and solar energy are concerned. Because wind and solar plants are strongly impacted by weather, high-resolution and high-quality weather data are required to drive power system simulations. Future data sets will have to push limits of numerical weather prediction to yield these high-resolution data sets, and wind data will have to be time-synchronized with solar data. Current wind and solar integration data sets are presented. The Wind Integration National Dataset (WIND) Toolkit is the largest and most complete grid integration data set publicly available to date. A meteorological data set, wind power production time series, and simulated forecasts created using the Weather Research and Forecasting Model run on a 2-km grid over the continental United States at a 5-min resolution is now publicly available for more than 126,000 land-based and offshore wind power production sites. The National Solar Radiation Database (NSRDB) is a similar high temporal- and spatial resolution database of 18 years of solar resource data for North America and India. The need for high-resolution weather data pushes modeling towards finer scales and closer synchronization. We also present how we anticipate such datasets developing in the future, their benefits, and the challenges with using and disseminating such large amounts of data.

  19. Reproducibility and Reliability of the Quality of Life Questionnaire in Patients With Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Rita Simone Lopes Moreira

    2016-03-01

    Full Text Available Abstract Background: Studies have shown the impact of atrial fibrillation (AF on the patients' quality of life. Specific questionnaires enable the evaluation of relevant events. We previously developed a questionnaire to assess the quality of life of patients with AF (AFQLQ version 1, which was reviewed in this study, and new domains were added. Objective: To demonstrate the reproducibility of the AFQLQ version 2 (AFQLQ v.2, which included the domains of fatigue, illness perception and well-being. Methods: We applied 160 questionnaires (AFQLQ v.2 and SF-36 to 40 patients, at baseline and 15 days after, to measure inter- and intraobserver reproducibility. The analysis of quality of life stability was determined by test-retest, applying the Bartko intraclass correlation coefficient (ICC. Internal consistency was assessed by Cronbach's alpha test. Results: The total score of the test-retest (n = 40 had an ICC of 0.98 in the AFQLQ v.2, and of 0.94 in the SF36. In assessing the intra- and interobserver reproducibility of the AFQLQ v.2, the ICC reliability was 0.98 and 0.97, respectively. The internal consistency had a Cronbach's alpha coefficient of 0.82, compatible with good agreement of the AFQLQ v.2. Conclusion: The AFQLQ v.2 performed better than its previous version. Similarly, the domains added contributed to make it more comprehensive and robust to assess the quality of life of patients with AF.

  20. The Accelerator Reliability Forum

    CERN Document Server

    Lüdeke, Andreas; Giachino, R

    2014-01-01

    A high reliability is a very important goal for most particle accelerators. The biennial Accelerator Reliability Workshop covers topics related to the design and operation of particle accelerators with a high reliability. In order to optimize the over-all reliability of an accelerator one needs to gather information on the reliability of many different subsystems. While a biennial workshop can serve as a platform for the exchange of such information, the authors aimed to provide a further channel to allow for a more timely communication: the Particle Accelerator Reliability Forum [1]. This contribution will describe the forum and advertise it’s usage in the community.

  1. Supporting visual quality assessment with machine learning

    NARCIS (Netherlands)

    Gastaldo, P.; Zunino, R.; Redi, J.

    2013-01-01

    Objective metrics for visual quality assessment often base their reliability on the explicit modeling of the highly non-linear behavior of human perception; as a result, they may be complex and computationally expensive. Conversely, machine learning (ML) paradigms allow to tackle the quality

  2. High-quality compressive ghost imaging

    Science.gov (United States)

    Huang, Heyan; Zhou, Cheng; Tian, Tian; Liu, Dongqi; Song, Lijun

    2018-04-01

    We propose a high-quality compressive ghost imaging method based on projected Landweber regularization and guided filter, which effectively reduce the undersampling noise and improve the resolution. In our scheme, the original object is reconstructed by decomposing of regularization and denoising steps instead of solving a minimization problem in compressive reconstruction process. The simulation and experimental results show that our method can obtain high ghost imaging quality in terms of PSNR and visual observation.

  3. Identifying factors influencing reliability of professional systems

    NARCIS (Netherlands)

    Balasubramanian, A.; Kevrekidis, K.; Sonnemans, P.J.M.; Newby, M.J.

    2008-01-01

    Modern product development strategies call for a more proactive approach to fight intense global competition in terms of technological innovation, shorter time to market, quality and reliability and accommodative price. From a reliability engineering perspective, development managers would like to

  4. Electronic versus paper-based assessment of health-related quality of life specific to HIV disease: reliability study of the PROQOL-HIV questionnaire.

    Science.gov (United States)

    Duracinsky, Martin; Lalanne, Christophe; Goujard, Cécile; Herrmann, Susan; Cheung-Lung, Christian; Brosseau, Jean-Paul; Schwartz, Yannick; Chassany, Olivier

    2014-04-25

    Electronic patient-reported outcomes (PRO) provide quick and usually reliable assessments of patients' health-related quality of life (HRQL). An electronic version of the Patient-Reported Outcomes Quality of Life-human immunodeficiency virus (PROQOL-HIV) questionnaire was developed, and its face validity and reliability were assessed using standard psychometric methods. A sample of 80 French outpatients (66% male, 52/79; mean age 46.7 years, SD 10.9) were recruited. Paper-based and electronic questionnaires were completed in a randomized crossover design (2-7 day interval). Biomedical data were collected. Questionnaire version and order effects were tested on full-scale scores in a 2-way ANOVA with patients as random effects. Test-retest reliability was evaluated using Pearson and intraclass correlation coefficients (ICC, with 95% confidence interval) for each dimension. Usability testing was carried out from patients' survey reports, specifically, general satisfaction, ease of completion, quality and clarity of user interface, and motivation to participate in follow-up PROQOL-HIV electronic assessments. Questionnaire version and administration order effects (N=59 complete cases) were not significant at the 5% level, and no interaction was found between these 2 factors (P=.94). Reliability indexes were acceptable, with Pearson correlations greater than .7 and ICCs ranging from .708 to .939; scores were not statistically different between the two versions. A total of 63 (79%) complete patients' survey reports were available, and 55% of patients (30/55) reported being satisfied and interested in electronic assessment of their HRQL in clinical follow-up. Individual ratings of PROQOL-HIV user interface (85%-100% of positive responses) confirmed user interface clarity and usability. The electronic PROQOL-HIV introduces minor modifications to the original paper-based version, following International Society for Pharmacoeconomics and Outcomes Research (ISPOR) ePRO Task

  5. Post-examination interpretation of objective test data: monitoring and improving the quality of high-stakes examinations--a commentary on two AMEE Guides.

    Science.gov (United States)

    Tavakol, Mohsen; Dennick, Reg

    2012-01-01

    As great emphasis is rightly placed upon the importance of assessment to judge the quality of our future healthcare professionals, it is appropriate not only to choose the most appropriate assessment method, but to continually monitor the quality of the tests themselves, in a hope that we may continually improve the process. This article stresses the importance of quality control mechanisms in the exam cycle and briefly outlines some of the key psychometric concepts including reliability measures, factor analysis, generalisability theory and item response theory. The importance of such analyses for the standard setting procedures is emphasised. This article also accompanies two new AMEE Guides in Medical Education (Tavakol M, Dennick R. Post-examination Analysis of Objective Tests: AMEE Guide No. 54 and Tavakol M, Dennick R. 2012. Post examination analysis of objective test data: Monitoring and improving the quality of high stakes examinations: AMEE Guide No. 66) which provide the reader with practical examples of analysis and interpretation, in order to help develop valid and reliable tests.

  6. Comparison of Quantity Versus Quality Using Performance, Reliability, and Life Cycle Cost Data. A Case Study of the F-15, F-16, and A-10 Aircraft.

    Science.gov (United States)

    1985-09-01

    CoC S~04 COMPARISON OF QUANTITY VERSUS QUALITY USING PERFORMANCE, RELIABILITY, AND LIFE CYCLE COST DATA. A CASE STUDY OF THE F-15, F-16, AND A-10...CYCLE COSTIATU.AT CAE AIR ORE HEO OG .- jAITR UIVERSITY W right.,Patterson Air Force Base, Ohio .! 5ൔ ,6 198 C.IT. U AF’IT/GSL,4/L3Q/65:S Ŗ J...COMPARISON OF QUANTITY VERSUS QUALITY USING PERFORMANCE, RELIABILITY, AND LIFE CYCLE COST DATA. A CASE STUDY OF THE F-15, F-16, AND A-10 AIRCRAFT THESIS David

  7. An Intuitionistic Fuzzy Methodology for Component-Based Software Reliability Optimization

    DEFF Research Database (Denmark)

    Madsen, Henrik; Grigore, Albeanu; Popenţiuvlǎdicescu, Florin

    2012-01-01

    Component-based software development is the current methodology facilitating agility in project management, software reuse in design and implementation, promoting quality and productivity, and increasing the reliability and performability. This paper illustrates the usage of intuitionistic fuzzy...... degree approach in modelling the quality of entities in imprecise software reliability computing in order to optimize management results. Intuitionistic fuzzy optimization algorithms are proposed to be used for complex software systems reliability optimization under various constraints....

  8. Offshore compression system design for low cost high and reliability

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Carlos J. Rocha de O.; Carrijo Neto, Antonio Dias; Cordeiro, Alexandre Franca [Chemtech Engineering Services and Software Ltd., Rio de Janeiro, RJ (Brazil). Special Projects Div.], Emails: antonio.carrijo@chemtech.com.br, carlos.rocha@chemtech.com.br, alexandre.cordeiro@chemtech.com.br

    2010-07-01

    In the offshore oil fields, the oil streams coming from the wells usually have significant amounts of gas. This gas is separated at low pressure and has to be compressed to the export pipeline pressure, usually at high pressure to reduce the needed diameter of the pipelines. In the past, this gases where flared, but nowadays there are a increasing pressure for the energy efficiency improvement of the oil rigs and the use of this gaseous fraction. The most expensive equipment of this kind of plant are the compression and power generation systems, being the second a strong function of the first, because the most power consuming equipment are the compressors. For this reason, the optimization of the compression system in terms of efficiency and cost are determinant to the plant profit. The availability of the plants also have a strong influence in the plant profit, specially in gas fields where the products have a relatively low aggregated value, compared to oil. Due this, the third design variable of the compression system becomes the reliability. As high the reliability, larger will be the plant production. The main ways to improve the reliability of compression system are the use of multiple compression trains in parallel, in a 2x50% or 3x50% configuration, with one in stand-by. Such configurations are possible and have some advantages and disadvantages, but the main side effect is the increase of the cost. This is the offshore common practice, but that does not always significantly improve the plant availability, depending of the previous process system. A series arrangement and a critical evaluation of the overall system in some cases can provide a cheaper system with equal or better performance. This paper shows a case study of the procedure to evaluate a compression system design to improve the reliability but without extreme cost increase, balancing the number of equipment, the series or parallel arrangement, and the driver selection. Two cases studies will be

  9. Accelerated life testing and reliability of high K multilayer ceramic capacitors

    Science.gov (United States)

    Minford, W. J.

    1981-01-01

    The reliability of one lot of high K multilayer ceramic capacitors was evaluated using accelerated life testing. The degradation in insulation resistance was characterized as a function of voltage and temperature. The times to failure at a voltage-temperature stress conformed to a lognormal distribution with a standard deviation approximately 0.5.

  10. Overview of system reliability analyses for PSA

    International Nuclear Information System (INIS)

    Matsuoka, Takeshi

    2012-01-01

    Overall explanations are given for many matters relating to system reliability analysis. Systems engineering, Operations research, Industrial engineering, Quality control are briefly explained. Many system reliability analysis methods including advanced methods are introduced. Discussions are given for FMEA, reliability block diagram, Markov model, Petri net, Bayesian network, goal tree success tree, dynamic flow graph methodology, cell-to-cell mapping technique, the GO-FLOW and others. (author)

  11. Assessing movement quality in persons with severe mental illness - Reliability and validity of the Body Awareness Scale Movement Quality and Experience.

    Science.gov (United States)

    Hedlund, Lena; Gyllensten, Amanda Lundvik; Waldegren, Tomas; Hansson, Lars

    2016-05-01

    Motor disturbances and disturbed self-recognition are common features that affect mobility in persons with schizophrenia spectrum disorder and bipolar disorder. Physiotherapists in Scandinavia assess and treat movement difficulties in persons with severe mental illness. The Body Awareness Scale Movement Quality and Experience (BAS MQ-E) is a new and shortened version of the commonly used Body Awareness Scale-Health (BAS-H). The purpose of this study was to investigate the inter-rater reliability and the concurrent validity of BAS MQ-E in persons with severe mental illness. The concurrent validity was examined by investigating the relationships between neurological soft signs, alexithymia, fatigue, anxiety, and mastery. Sixty-two persons with severe mental illness participated in the study. The results showed a satisfactory inter-rater reliability (n = 53) and a concurrent validity (n = 62) with neurological soft signs, especially cognitive and perceptual based signs. There was also a concurrent validity linked to physical fatigue and aspects of alexithymia. The scores of BAS MQ-E were in general higher for persons with schizophrenia compared to persons with other diagnoses within the schizophrenia spectrum disorders and bipolar disorder. The clinical implications are presented in the discussion.

  12. Standard semiconductor packaging for high-reliability low-cost MEMS applications

    Science.gov (United States)

    Harney, Kieran P.

    2005-01-01

    Microelectronic packaging technology has evolved over the years in response to the needs of IC technology. The fundamental purpose of the package is to provide protection for the silicon chip and to provide electrical connection to the circuit board. Major change has been witnessed in packaging and today wafer level packaging technology has further revolutionized the industry. MEMS (Micro Electro Mechanical Systems) technology has created new challenges for packaging that do not exist in standard ICs. However, the fundamental objective of MEMS packaging is the same as traditional ICs, the low cost and reliable presentation of the MEMS chip to the next level interconnect. Inertial MEMS is one of the best examples of the successful commercialization of MEMS technology. The adoption of MEMS accelerometers for automotive airbag applications has created a high volume market that demands the highest reliability at low cost. The suppliers to these markets have responded by exploiting standard semiconductor packaging infrastructures. However, there are special packaging needs for MEMS that cannot be ignored. New applications for inertial MEMS devices are emerging in the consumer space that adds the imperative of small size to the need for reliability and low cost. These trends are not unique to MEMS accelerometers. For any MEMS technology to be successful the packaging must provide the basic reliability and interconnection functions, adding the least possible cost to the product. This paper will discuss the evolution of MEMS packaging in the accelerometer industry and identify the main issues that needed to be addressed to enable the successful commercialization of the technology in the automotive and consumer markets.

  13. Highly Reliable PON Optical Splitters for Optical Access Networks in Outside Environments

    Science.gov (United States)

    Watanabe, Hiroshi; Araki, Noriyuki; Fujimoto, Hisashi

    Broadband optical access services are spreading throughout the world, and the number of fiber to the home (FTTH) subscribers is increasing rapidly. Telecom operators are constructing passive optical networks (PONs) to provide optical access services. Externally installed optical splitters for PONs are very important passive devices in optical access networks, and they must provide satisfactory performance as outdoor plant over long periods. Therefore, we calculate the failure rate of optical access networks and assign a failure rate to the optical splitters in optical access networks. The maximum cumulative failure rate of 1 × 8 optical splitters was calculated as 0.025 for an optical access fiber length of 2.1km and a 20-year operating lifetime. We examined planar lightwave circuit (PLC) type optical splitters for use as outside plant in terms of their optical characteristics and environmental reliability. We confirmed that PLC type optical splitters have sufficient optical performance for a PON splitter and sufficient reliability as outside plant in accordance with ITU-T standard values. We estimated the lifetimes of three kinds of PLC type optical splitters by using accelerated aging tests. The estimated failure rate of these splitters installed in optical access networks was below the target value for the cumulative failure rate, and we confirmed that they have sufficient reliability to maintain the quality of the network service. We developed 1 × 8 optical splitter modules with plug and socket type optical connectors and optical fiber cords for optical aerial closures designed for use as outside plant. These technologies make it easy to install optical splitters in an aerial optical closure. The optical splitter modules have sufficient optical performance levels for PONs because the insertion loss at the commercially used wavelengths of 1.31 and 1.55µm is less than the criterion established by ITU-T Recommendation G.671 for optical splitters. We performed a

  14. Improved Yield, Performance and Reliability of High-Actuator-Count Deformable Mirrors, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The project team will conduct processing and design research aimed at improving yield, performance, and reliability of high-actuator-count micro-electro-mechanical...

  15. Feasibility, reliability and validity of the Thai version of the Pediatric Quality of Life Inventory 3.0 cerebral palsy module.

    Science.gov (United States)

    Tantilipikorn, Pinailug; Watter, Pauline; Prasertsukdee, Saipin

    2013-03-01

    Quality of Life (QOL) and Health-related Quality of Life (HRQOL) are now considered as necessary outcome measures for children with cerebral palsy (CP). Various reliable and valid condition-specific HRQOL tools are available for these children. One of these is Pediatric Quality of Life Inventory (PedsQL) 3.0 CP module which has been widely used and was translated to many languages. As no Thai version is available, the authors have completed this translation. This study then aimed to investigate psychometric properties of the newly translated Thai PedsQL 3.0 CP module and to establish parent confidence in their ratings in the translated tool. Translation of the PedsQL 3.0 CP module was performed based on linguistic translation guidelines. Then, the psychometric properties of the Thai version were established. PedsQL 3.0 CP module was completed by children with CP and their parents or caregivers twice with 2-4 weeks. Respondents were 97 parents or caregivers and 54 children. Minimal missing data were found. Acceptable internal consistency was supported except for Movement and Balance Scale (self-report). Intraclass correlation coefficients for parent proxy and self-report were good to excellent (0.684-0.950). The feasibility, reliability and validity of the translated tool were supported.

  16. Reliability of physical examination for diagnosis of myofascial trigger points: a systematic review of the literature.

    Science.gov (United States)

    Lucas, Nicholas; Macaskill, Petra; Irwig, Les; Moran, Robert; Bogduk, Nikolai

    2009-01-01

    Trigger points are promoted as an important cause of musculoskeletal pain. There is no accepted reference standard for the diagnosis of trigger points, and data on the reliability of physical examination for trigger points are conflicting. To systematically review the literature on the reliability of physical examination for the diagnosis of trigger points. MEDLINE, EMBASE, and other sources were searched for articles reporting the reliability of physical examination for trigger points. Included studies were evaluated for their quality and applicability, and reliability estimates were extracted and reported. Nine studies were eligible for inclusion. None satisfied all quality and applicability criteria. No study specifically reported reliability for the identification of the location of active trigger points in the muscles of symptomatic participants. Reliability estimates varied widely for each diagnostic sign, for each muscle, and across each study. Reliability estimates were generally higher for subjective signs such as tenderness (kappa range, 0.22-1.0) and pain reproduction (kappa range, 0.57-1.00), and lower for objective signs such as the taut band (kappa range, -0.08-0.75) and local twitch response (kappa range, -0.05-0.57). No study to date has reported the reliability of trigger point diagnosis according to the currently proposed criteria. On the basis of the limited number of studies available, and significant problems with their design, reporting, statistical integrity, and clinical applicability, physical examination cannot currently be recommended as a reliable test for the diagnosis of trigger points. The reliability of trigger point diagnosis needs to be further investigated with studies of high quality that use current diagnostic criteria in clinically relevant patients.

  17. Design and reliability, availability, maintainability, and safety analysis of a high availability quadruple vital computer system

    Institute of Scientific and Technical Information of China (English)

    Ping TAN; Wei-ting HE; Jia LIN; Hong-ming ZHAO; Jian CHU

    2011-01-01

    With the development of high-speed railways in China,more than 2000 high-speed trains will be put into use.Safety and efficiency of railway transportation is increasingly important.We have designed a high availability quadruple vital computer (HAQVC) system based on the analysis of the architecture of the traditional double 2-out-of-2 system and 2-out-of-3 system.The HAQVC system is a system with high availability and safety,with prominent characteristics such as fire-new internal architecture,high efficiency,reliable data interaction mechanism,and operation state change mechanism.The hardware of the vital CPU is based on ARM7 with the real-time embedded safe operation system (ES-OS).The Markov modeling method is designed to evaluate the reliability,availability,maintainability,and safety (RAMS) of the system.In this paper,we demonstrate that the HAQVC system is more reliable than the all voting triple modular redundancy (AVTMR) system and double 2-out-of-2 system.Thus,the design can be used for a specific application system,such as an airplane or high-speed railway system.

  18. Design reliability engineering

    International Nuclear Information System (INIS)

    Buden, D.; Hunt, R.N.M.

    1989-01-01

    Improved design techniques are needed to achieve high reliability at minimum cost. This is especially true of space systems where lifetimes of many years without maintenance are needed and severe mass limitations exist. Reliability must be designed into these systems from the start. Techniques are now being explored to structure a formal design process that will be more complete and less expensive. The intent is to integrate the best features of design, reliability analysis, and expert systems to design highly reliable systems to meet stressing needs. Taken into account are the large uncertainties that exist in materials, design models, and fabrication techniques. Expert systems are a convenient method to integrate into the design process a complete definition of all elements that should be considered and an opportunity to integrate the design process with reliability, safety, test engineering, maintenance and operator training. 1 fig

  19. Factors Influencing the Reliability of the Glasgow Coma Scale: A Systematic Review.

    Science.gov (United States)

    Reith, Florence Cm; Synnot, Anneliese; van den Brande, Ruben; Gruen, Russell L; Maas, Andrew Ir

    2017-06-01

    The Glasgow Coma Scale (GCS) characterizes patients with diminished consciousness. In a recent systematic review, we found overall adequate reliability across different clinical settings, but reliability estimates varied considerably between studies, and methodological quality of studies was overall poor. Identifying and understanding factors that can affect its reliability is important, in order to promote high standards for clinical use of the GCS. The aim of this systematic review was to identify factors that influence reliability and to provide an evidence base for promoting consistent and reliable application of the GCS. A comprehensive literature search was undertaken in MEDLINE, EMBASE, and CINAHL from 1974 to July 2016. Studies assessing the reliability of the GCS in adults or describing any factor that influences reliability were included. Two reviewers independently screened citations, selected full texts, and undertook data extraction and critical appraisal. Methodological quality of studies was evaluated with the consensus-based standards for the selection of health measurement instruments checklist. Data were synthesized narratively and presented in tables. Forty-one studies were included for analysis. Factors identified that may influence reliability are education and training, the level of consciousness, and type of stimuli used. Conflicting results were found for experience of the observer, the pathology causing the reduced consciousness, and intubation/sedation. No clear influence was found for the professional background of observers. Reliability of the GCS is influenced by multiple factors and as such is context dependent. This review points to the potential for improvement from training and education and standardization of assessment methods, for which recommendations are presented. Copyright © 2017 by the Congress of Neurological Surgeons.

  20. Reliability of Wireless Sensor Networks

    Science.gov (United States)

    Dâmaso, Antônio; Rosa, Nelson; Maciel, Paulo

    2014-01-01

    Wireless Sensor Networks (WSNs) consist of hundreds or thousands of sensor nodes with limited processing, storage, and battery capabilities. There are several strategies to reduce the power consumption of WSN nodes (by increasing the network lifetime) and increase the reliability of the network (by improving the WSN Quality of Service). However, there is an inherent conflict between power consumption and reliability: an increase in reliability usually leads to an increase in power consumption. For example, routing algorithms can send the same packet though different paths (multipath strategy), which it is important for reliability, but they significantly increase the WSN power consumption. In this context, this paper proposes a model for evaluating the reliability of WSNs considering the battery level as a key factor. Moreover, this model is based on routing algorithms used by WSNs. In order to evaluate the proposed models, three scenarios were considered to show the impact of the power consumption on the reliability of WSNs. PMID:25157553

  1. Product analysis and initial reliability testing of the total mesorectal excision-quality assessment instrument.

    Science.gov (United States)

    Simunovic, Marko R; DeNardi, Franco G; Coates, Angela J; Szalay, David A; Eva, Kevin W

    2014-07-01

    Product analysis of rectal cancer resection specimens before specimen fixation may provide an immediate and relevant evaluation of surgical performance. We tested the interrater reliability (IRR) of a product analysis tool called the Total Mesorectal Excision-Quality Assessment Instrument (TME-QA). Participants included two gold standard raters, five pathology assistants, and eight pathologists. Domains of the TME-QA reflect total mesorectal excision principles including: (1) completeness of mesorectal margin; (2) completeness of mesorectum; (3) coning of distal mesorectum; (4) physical defects; and (5) overall specimen quality. Specimens were scored independently. We used the generalizability theory to assess the tool's internal consistency and IRR. There were 39 specimens and 120 ratings. Mean overall specimen quality scores for the gold standard raters, pathologists, and assistants were 4.43, 4.43, and 4.50, respectively (p > 0.85). IRR for the first nine items was 0.68 for the full sample, 0.62 for assistants alone, 0.63 for pathologists alone, and 0.74 for gold standard raters alone. IRR for the item overall specimen quality was 0.67 for the full sample, 0.45 for assistants, 0.80 for pathologists, and 0.86 for gold standard raters. IRR increased for all groups when scores were averaged across two raters. Assessment of surgical specimens using the TME-QA may provide rapid and relevant feedback to surgeons about their technical performance. Our results show good internal consistency and IRR when the TME-QA is used by pathologists. However, for pathology assistants, multiple ratings with the averaging of scores may be needed.

  2. Advanced Functionalities for Highly Reliable Optical Networks

    DEFF Research Database (Denmark)

    An, Yi

    This thesis covers two research topics concerning optical solutions for networks e.g. avionic systems. One is to identify the applications for silicon photonic devices for cost-effective solutions in short-range optical networks. The other one is to realise advanced functionalities in order...... to increase the availability of highly reliable optical networks. A cost-effective transmitter based on a directly modulated laser (DML) using a silicon micro-ring resonator (MRR) to enhance its modulation speed is proposed, analysed and experimentally demonstrated. A modulation speed enhancement from 10 Gbit...... interconnects and network-on-chips. A novel concept of all-optical protection switching scheme is proposed, where fault detection and protection trigger are all implemented in the optical domain. This scheme can provide ultra-fast establishment of the protection path resulting in a minimum loss of data...

  3. Mechanical reliability of bulk high Tc superconductors

    International Nuclear Information System (INIS)

    Freiman, S.W.

    1990-01-01

    Most prospective applications for high T c superconductors in bulk form, e.g. magnets, motors, will require appreciable mechanical strength. Work at NIST [National Institute of Standards and Technology] has begun to address issues related to mechanical reliability. For example, recent studies on Ba-Y-Cu-O have shown that the intrinsic crack growth resistance, K IC , of crystals of this material is even smaller than was first reported, less than that of window glass, and is sensitive to moisture. Processing conditions, particularly sintering and annealing atmosphere, have been shown to have a major influence on microstructure and internal stresses in the material. Large internal stresses result from the tetragonal to orthorhombic phase transformation as well as the thermal expansion anisotropy in the grains of the ceramic. Because stress relief is absent, microcracks form which have a profound influence on strength

  4. Implosion lessons from national security, high reliability spacecraft, electronics, and the forces which changed them

    CERN Document Server

    Temple, L Parker

    2012-01-01

    Implosion is a focused study of the history and uses of high-reliability, solid-state electronics, military standards, and space systems that support our national security and defense. This book is unique in combining the interdependent evolution of and interrelationships among military standards, solid-state electronics, and very high-reliability space systems. Starting with a brief description of the physics that enabled the development of the first transistor, Implosion covers the need for standardizing military electronics, which began during World War II and continu

  5. Reliability and validity of academic motivation scale for sports high school students’

    Directory of Open Access Journals (Sweden)

    Haslofça Fehime

    2016-01-01

    Full Text Available This study was designed to test validity and reliability of Academic Motivation Scale (AMS for sports high school students. The research conducted with 357 volunteered girls (n=117 and boys (n=240. Confirmatory factor analysis showed that Chi square (χ2, degrees of freedom (df and χ2/df ratio were 1102.90, 341 and 3.234, respectively. Goodness of Fit Index, Comparative Fit Index, Non-normed Fit Index and Incremental Fit Index were between 0.92-0.95. Additionally, Adjusted Goodness of Fit Index, An Average Errors Square Root and Root Mean Square Error of Approximation were 0.88, 0.070 and 0.079, respectively. Subscale reliability coefficients were between 0.77 and 0.86. Test-retest correlations of AMS were found between 0.79 and 0.91. Results showed that scale was suitable for determination of sports high school students’ academicals motivation levels.

  6. Practical considerations for obtaining high quality quantitative computed tomography data of the skeletal system.

    Science.gov (United States)

    Troy, Karen L; Edwards, W Brent

    2018-05-01

    Quantitative CT (QCT) analysis involves the calculation of specific parameters such as bone volume and density from CT image data, and can be a powerful tool for understanding bone quality and quantity. However, without careful attention to detail during all steps of the acquisition and analysis process, data can be of poor- to unusable-quality. Good quality QCT for research requires meticulous attention to detail and standardization of all aspects of data collection and analysis to a degree that is uncommon in a clinical setting. Here, we review the literature to summarize practical and technical considerations for obtaining high quality QCT data, and provide examples of how each recommendation affects calculated variables. We also provide an overview of the QCT analysis technique to illustrate additional opportunities to improve data reproducibility and reliability. Key recommendations include: standardizing the scanner and data acquisition settings, minimizing image artifacts, selecting an appropriate reconstruction algorithm, and maximizing repeatability and objectivity during QCT analysis. The goal of the recommendations is to reduce potential sources of error throughout the analysis, from scan acquisition to the interpretation of results. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Automated high speed volume computed tomography for inline quality control

    International Nuclear Information System (INIS)

    Hanke, R.; Kugel, A.; Troup, P.

    2004-01-01

    Increasing complexity of innovative products as well as growing requirements on quality and reliability call for more detailed knowledge about internal structures of manufactured components rather by 100 % inspection than just by sampling test. A first-step solution, like radioscopic inline inspection machines, equipped with automated data evaluation software, have become state of the art in the production floor during the last years. However, these machines provide just ordinary two-dimensional information and deliver no volume data e.g. to evaluate exact position or shape of detected defects. One way to solve this problem is the application of X-ray computed tomography (CT). Compared to the performance of the first generation medical scanners (scanning times of many hours), today, modern Volume CT machines for industrial applications need about 5 minutes for a full object scan depending on the object size. Of course, this is still too long to introduce this powerful method into the inline production quality control. In order to gain acceptance, the scanning time including subsequent data evaluation must be decreased significantly and adapted to the manufacturing cycle times. This presentation demonstrates the new technical set up, reconstruction results and the methods for high-speed volume data evaluation of a new fully automated high-speed CT scanner with cycle times below one minute for an object size of less than 15 cm. This will directly create new opportunities in design and construction of more complex objects. (author)

  8. Signal Quality Outage Analysis for Ultra-Reliable Communications in Cellular Networks

    DEFF Research Database (Denmark)

    Gerardino, Guillermo Andrés Pocovi; Alvarez, Beatriz Soret; Lauridsen, Mads

    2015-01-01

    Ultra-reliable communications over wireless will open the possibility for a wide range of novel use cases and applications. In cellular networks, achieving reliable communication is challenging due to many factors, particularly the fading of the desired signal and the interference. In this regard......, we investigate the potential of several techniques to combat these main threats. The analysis shows that traditional microscopic multiple-input multiple-output schemes with 2x2 or 4x4 antenna configurations are not enough to fulfil stringent reliability requirements. It is revealed how such antenna...... schemes must be complemented with macroscopic diversity as well as interference management techniques in order to ensure the necessary SINR outage performance. Based on the obtained performance results, it is discussed which of the feasible options fulfilling the ultra-reliable criteria are most promising...

  9. Evaluating the Validity and Reliability of Customer Quality Questionnaire from the Experts’ and Customers’ Perspective in Services Related to Patients With Inflammatory Bowel Disease

    Directory of Open Access Journals (Sweden)

    Roya Hasanzadeh

    2015-08-01

    Full Text Available ​ Background and Objectives : Customer Quality refers to   customers’ capabilities to be effectively participating in service delivery and correct care processes. The aim of this study was to evaluate the validity and reliability of customer quality questionnaire in services related to  patients with Inflammatory Bowel Disease. Material and Methods : This is a qualitative study with the aim of assessment of customer quality questionnaire with 16 questions. This questionnaire was distributed among 11 experts to determine the validity of the questionnaire. Finally, 10 of them expressed their own opinions based on the criteria of validity and in the face validity section , they expressed their opinions qualitatively. Also, reliability of questionnaire was reviewed with 30 samples, according to the internal consistency. Results : In determining the content validity, all the questionnaire items were confirmed by CVR (1 and CVI (0.89 indicators. Also, reliability of the questionnaire was confirmed by Cronbach’s alpha (α=0.78.The final questionnaire was changed according to the experts’ recommendations and their qualitative comments on the 19 questions in four stages of customer quality, including: a the patient’s belief that his/her role in care process is important, b having knowledge, skill and confidence to take action in the care process, c  taking action to protect and improve the health or active involvement, d continuity of care, even in critical situations and under stress. Conclusion : Confirmation of the questionnaire with statistical scientific methods showed that this questionnaire is a very strong tool that using it in research can be an effective step in order to improve the quality of health services.

  10. 650-nm-band high-power and highly reliable laser diodes with a window-mirror structure

    Science.gov (United States)

    Shima, Akihiro; Hironaka, Misao; Ono, Ken-ichi; Takemi, Masayoshi; Sakamoto, Yoshifumi; Kunitsugu, Yasuhiro; Yamashita, Koji

    1998-05-01

    An active layer structure with 658 nm-emission at 25 degrees Celsius has been optimized in order to reduce the operating current of the laser diodes (LD) under high temperature condition. For improvement of the maximum output power and the reliability limited by mirror degradation, we have applied a zinc-diffused-type window-mirror structure which prevents the optical absorption at the mirror facet. As a result, the CW output power of 50 mW is obtained even at 80 degrees Celsius for a 650 micrometer-long window-mirror LD. In addition, the maximum light output power over 150 mW at 25 degrees Celsius has been realized without any optical mirror damage. In the aging tests, the LDs have been operating for over 2,500 - 5,000 hours under the CW condition of 30 - 50 mW at 60 degrees Celsius. The window-mirror structure also enables reliable 60 degree Celsius, 30 mW, CW operation of the LDs with 651 nm- emission at 25 degrees Celsius. Moreover, the maximum output power of around 100 mW even at 80 degrees Celsius and reliable 2,000-hour operation at 60 degrees Celsius, 70 mW have been realized for the first time by 659 nm LDs with a long cavity length of 900 micrometers.

  11. Health-related quality of life: validity, reliability, and responsiveness of SF-36, 15D, EQ-5D RAQoL, and HAQ in patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Linde, L.; Sørensen, J.; Østergaard, Morten

    2008-01-01

    OBJECTIVE: To compare validity, reliability, and responsiveness of generic and disease specific health-related quality of life (HRQOL) instruments in rheumatoid arthritis (RA). METHODS: Two samples of patients completed the Medical Outcomes Study Short Form-36 Health Survey (SF-36), EuroQol (EQ)-5D...... and VAS pain were responsive to both improvement and deterioration. CONCLUSION: All instruments were valid measures for HRQOL in RA. The RAQoL and HAQ displayed the best reliability, while the SF-36 bodily pain scale and VAS pain were the most responsive. The choice of instrument should depend......, 15D, Rheumatoid Arthritis Quality of Life Scale (RAQoL), Health Assessment Questionnaire (HAQ), and visual analog scales (VAS) for pain, fatigue, and global RA. Validity (convergent, discriminant, and known-groups) was evaluated in a cross-section of 200 patients. Reliability was evaluated...

  12. [Employees in high-reliability organizations: systematic selection of personnel as a final criterion].

    Science.gov (United States)

    Oubaid, V; Anheuser, P

    2014-05-01

    Employees represent an important safety factor in high-reliability organizations. The combination of clear organizational structures, a nonpunitive safety culture, and psychological personnel selection guarantee a high level of safety. The cockpit personnel selection process of a major German airline is presented in order to demonstrate a possible transferability into medicine and urology.

  13. Methods to achieve high interrater reliability in data collection from primary care medical records.

    Science.gov (United States)

    Liddy, Clare; Wiens, Miriam; Hogg, William

    2011-01-01

    We assessed interrater reliability (IRR) of chart abstractors within a randomized trial of cardiovascular care in primary care. We report our findings, and outline issues and provide recommendations related to determining sample size, frequency of verification, and minimum thresholds for 2 measures of IRR: the κ statistic and percent agreement. We designed a data quality monitoring procedure having 4 parts: use of standardized protocols and forms, extensive training, continuous monitoring of IRR, and a quality improvement feedback mechanism. Four abstractors checked a 5% sample of charts at 3 time points for a predefined set of indicators of the quality of care. We set our quality threshold for IRR at a κ of 0.75, a percent agreement of 95%, or both. Abstractors reabstracted a sample of charts in 16 of 27 primary care practices, checking a total of 132 charts with 38 indicators per chart. The overall κ across all items was 0.91 (95% confidence interval, 0.90-0.92) and the overall percent agreement was 94.3%, signifying excellent agreement between abstractors. We gave feedback to the abstractors to highlight items that had a κ of less than 0.70 or a percent agreement less than 95%. No practice had to have its charts abstracted again because of poor quality. A 5% sampling of charts for quality control using IRR analysis yielded κ and agreement levels that met or exceeded our quality thresholds. Using 3 time points during the chart audit phase allows for early quality control as well as ongoing quality monitoring. Our results can be used as a guide and benchmark for other medical chart review studies in primary care.

  14. Protocol: A simple phenol-based method for 96-well extraction of high quality RNA from Arabidopsis

    Directory of Open Access Journals (Sweden)

    Coustham Vincent

    2011-03-01

    Full Text Available Abstract Background Many experiments in modern plant molecular biology require the processing of large numbers of samples for a variety of applications from mutant screens to the analysis of natural variants. A severe bottleneck to many such analyses is the acquisition of good yields of high quality RNA suitable for use in sensitive downstream applications such as real time quantitative reverse-transcription-polymerase chain reaction (real time qRT-PCR. Although several commercial kits are available for high-throughput RNA extraction in 96-well format, only one non-kit method has been described in the literature using the commercial reagent TRIZOL. Results We describe an unusual phenomenon when using TRIZOL reagent with young Arabidopsis seedlings. This prompted us to develop a high-throughput RNA extraction protocol (HTP96 adapted from a well established phenol:chloroform-LiCl method (P:C-L that is cheap, reliable and requires no specialist equipment. With this protocol 192 high quality RNA samples can be prepared in 96-well format in three hours (less than 1 minute per sample with less than 1% loss of samples. We demonstrate that the RNA derived from this protocol is of high quality and suitable for use in real time qRT-PCR assays. Conclusion The development of the HTP96 protocol has vastly increased our sample throughput, allowing us to fully exploit the large sample capacity of modern real time qRT-PCR thermocyclers, now commonplace in many labs, and develop an effective high-throughput gene expression platform. We propose that the HTP96 protocol will significantly benefit any plant scientist with the task of obtaining hundreds of high quality RNA extractions.

  15. Availability of high quality weather data measurements

    DEFF Research Database (Denmark)

    Andersen, Elsa; Johansen, Jakob Berg; Furbo, Simon

    In the period 2016-2017 the project “Availability of high quality weather data measurements” is carried out at Department of Civil Engineering at the Technical University of Denmark. The aim of the project is to establish measured high quality weather data which will be easily available...... for the building energy branch and the solar energy branch in their efforts to achieve energy savings and for researchers and students carrying out projects where measured high quality weather data are needed....

  16. OREDA offshore and onshore reliability data volume 1 - topside equipment

    CERN Document Server

    OREDA

    2015-01-01

    This handbook presents high quality reliability data for offshore equipment collected during phase VI to IX (project period 2000 – 2009) of the OREDA project. The intention of the handbook is to provide both quantitative and qualitative information as a basis for Performance Forecasting or RAMS (Reliability, Availability, Maintainability and Safety) analyses. Volume 1 is about Topside Equipment. Compared to earlier editions, there are only minor changes in the reliability data presentation. To obtain a reasonable population for presenting reliability data for topside equipment in the 2015 edition, some data from phases VI and VII already issued in the previous 2009 handbook (5th edition) have also been included. The 2015 topside volume is divided into two parts. Part I describes the OREDA project, different data collection phases and the estimation procedures used to generate the data tables presented in Part II of the handbook. Topside data are in general not covering the whole lifetime of equipment, but ...

  17. Reliable LED Lighting Technologies: Key Factors and Procurement Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Lynn; Arquit Niederberger, Anne

    2015-10-08

    Abstract— Lighting systems have the ability to transform the economic and educational infrastructure of disadvantaged communities, and eradicating “light poverty” has become one of the primary goals of the International Year of Light 2015. Solid-state lighting (SSL) technology, based on light-emitting diode (LED) light sources, has emerged as the next generation of lighting technology, with a current global market penetration of roughly 5%. This paper will report on recent research on understanding SSL lighting system reliability (failure modes, environmental stressors, electrical power quality); discuss the implications of SSL technology reliability for providing lighting services; and suggest practical approaches to ensure SSL reliability to benefit humanity. Among the key findings from this work is that LED sources can be extremely reliable, withstanding a broad range of environmental stresses without failure. Nonetheless, SSL lighting systems can have a negative impact on electrical power reliability, as well as on the affordability of lighting services, without attention to the quality of the accompanying power infrastructure. It is therefore critical to ensure that the performance of the power supply electronics used in lighting systems is matched to the quality of the power source, when evaluating energy efficient lighting choices.

  18. Operational experience, availability and reliability of nuclear power plants

    International Nuclear Information System (INIS)

    Kueffer, K.

    1980-01-01

    This lecture - presents a survey on nuclear power production and plant performance in the Western World covering all reactor types and light-water reactors in particular and discusses key parameters such as load factors and non-availability analysis. - outlines the main reasons for the reliable performance of Swiss nuclear power plants - quality equipment - operator qualification and training - engineering know how on site - maintenance philosophy and outage planning - information system and feedback of experience - explains the management functions as applied at the Beznau Nuclear Power Station to ensure high power productivity and reliability - improvement - a feedback control system - analysis of production losses - optimization in shut-down planning - minimizing disturbances during plant operation - optimizing personnel qualification and efficiency. (orig.)

  19. Reliability issues in PACS

    Science.gov (United States)

    Taira, Ricky K.; Chan, Kelby K.; Stewart, Brent K.; Weinberg, Wolfram S.

    1991-07-01

    Reliability is an increasing concern when moving PACS from the experimental laboratory to the clinical environment. Any system downtime may seriously affect patient care. The authors report on the several classes of errors encountered during the pre-clinical release of the PACS during the past several months and present the solutions implemented to handle them. The reliability issues discussed include: (1) environmental precautions, (2) database backups, (3) monitor routines of critical resources and processes, (4) hardware redundancy (networks, archives), and (5) development of a PACS quality control program.

  20. Optimization of a PCRAM Chip for high-speed read and highly reliable reset operations

    Science.gov (United States)

    Li, Xiaoyun; Chen, Houpeng; Li, Xi; Wang, Qian; Fan, Xi; Hu, Jiajun; Lei, Yu; Zhang, Qi; Tian, Zhen; Song, Zhitang

    2016-10-01

    The widely used traditional Flash memory suffers from its performance limits such as its serious crosstalk problems, and increasing complexity of floating gate scaling. Phase change random access memory (PCRAM) becomes one of the most potential nonvolatile memories among the new memory techniques. In this paper, a 1M-bit PCRAM chip is designed based on the SMIC 40nm CMOS technology. Focusing on the read and write performance, two new circuits with high-speed read operation and highly reliable reset operation are proposed. The high-speed read circuit effectively reduces the reading time from 74ns to 40ns. The double-mode reset circuit improves the chip yield. This 1M-bit PCRAM chip has been simulated on cadence. After layout design is completed, the chip will be taped out for post-test.

  1. Reliability Evaluation on Creep Life Prediction of Alloy 617 for a Very High Temperature Reactor

    International Nuclear Information System (INIS)

    Kim, Woo-Gon; Hong, Sung-Deok; Kim, Yong-Wan; Park, Jae-Young; Kim, Seon-Jin

    2012-01-01

    This paper evaluates the reliability of creep rupture life under service conditions of Alloy 617, which is considered as one of the candidate materials for use in a very high temperature reactor (VHTR) system. A Z-parameter, which represents the deviation of creep rupture data from the master curve, was used for the reliability analysis of the creep rupture data of Alloy 617. A Service-condition Creep Rupture Interference (SCRI) model, which can consider both the scattering of the creep rupture data and the fluctuations of temperature and stress under any service conditions, was also used for evaluating the reliability of creep rupture life. The statistical analysis showed that the scattering of creep rupture data based on Z-parameter was supported by normal distribution. The values of reliability decreased rapidly with increasing amplitudes of temperature and stress fluctuations. The results established that the reliability decreased with an increasing service time.

  2. An overview of the reliability prediction related aspects of high power IGBTs in wind power applications

    DEFF Research Database (Denmark)

    Busca, Christian; Teodorescu, Remus; Blaabjerg, Frede

    2011-01-01

    Reliability is becoming more and more important as the size and number of installed Wind Turbines (WTs) increases. Very high reliability is especially important for offshore WTs because the maintenance and repair of such WTs in case of failures can be very expensive. WT manufacturers need...

  3. Health-related quality of life: validity, reliability, and responsiveness of SF-36, 15D, EQ-5D [corrected] RAQoL, and HAQ in patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Linde, Louise; Sørensen, Jan; Ostergaard, Mikkel

    2008-01-01

    .21-6.47). The longitudinal sample included 80% women, median age 60 years (22-82). Validity: all instruments discriminated between low, moderate, and high DAS28. Reliability: RAQoL and HAQ displayed good repeatability (ICC > 0.95) and internal consistency (Cronbach's alpha > 0.90). Responsiveness: SF-36 bodily pain scale......, 15D, Rheumatoid Arthritis Quality of Life Scale (RAQoL), Health Assessment Questionnaire (HAQ), and visual analog scales (VAS) for pain, fatigue, and global RA. Validity (convergent, discriminant, and known-groups) was evaluated in a cross-section of 200 patients. Reliability was evaluated...... questionnaires (at 2 weeks and 6 months) included questions about changes in health status since baseline. RESULTS: The cross-sectional sample included 77% women, median age 57 years (range 19-87), disease duration 6 years (0-58), with Disease Activity Score 28-joint count (DAS28) of 3.10 (1...

  4. Reliability and Characterization of High Voltage Power Capacitors

    Science.gov (United States)

    2014-03-01

    in a Faraday cage to minimize external noise. In addition, electron microscopy could also be performed to identify the change in trap concentration...military bases in the United States. Energy product reliability affects the sustainability and cost- effectiveness of these systems, which must be tested...Energy product reliability affects the sustainability and cost- effectiveness of these systems, which must be tested by outside entities to ensure

  5. Stroke Impact Scale 3.0: Reliability and Validity Evaluation of the Korean Version.

    Science.gov (United States)

    Choi, Seong Uk; Lee, Hye Sun; Shin, Joon Ho; Ho, Seung Hee; Koo, Mi Jung; Park, Kyoung Hae; Yoon, Jeong Ah; Kim, Dong Min; Oh, Jung Eun; Yu, Se Hwa; Kim, Dong A

    2017-06-01

    To establish the reliability and validity the Korean version of the Stroke Impact Scale (K-SIS) 3.0. A total of 70 post-stroke patients were enrolled. All subjects were evaluated for general characteristics, Mini-Mental State Examination (MMSE), the National Institutes of Health Stroke Scale (NIHSS), Modified Barthel Index, Hospital Anxiety and Depression Scale (HADS). The SF-36 and K-SIS 3.0 assessed their health-related quality of life. Statistical analysis after evaluation, determined the reliability and validity of the K-SIS 3.0. A total of 70 patients (mean age, 54.97 years) participated in this study. Internal consistency of the SIS 3.0 (Cronbach's alpha) was obtained, and all domains had good co-efficiency, with threshold above 0.70. Test-retest reliability of SIS 3.0 required correlation (Spearman's rho) of the same domain scores obtained on the first and second assessments. Results were above 0.5, with the exception of social participation and mobility. Concurrent validity of K-SIS 3.0 was assessed using the SF-36, and other scales with the same or similar domains. Each domain of K-SIS 3.0 had a positive correlation with corresponding similar domain of SF-36 and other scales (HADS, MMSE, and NIHSS). The newly developed K-SIS 3.0 showed high inter-intra reliability and test-retest reliabilities, together with high concurrent validity with the original and various other scales, for patients with stroke. K-SIS 3.0 can therefore be used for stroke patients, to assess their health-related quality of life and treatment efficacy.

  6. Reliability and validity of a self-administration version of DEMQOL-Proxy.

    Science.gov (United States)

    Hendriks, A A Jolijn; Smith, Sarah C; Chrysanthaki, Theopisti; Black, Nick

    2017-07-01

    This study aimed to investigate the reliability and validity of a self-administered version of DEMQOL-Proxy, a disease-specific instrument that measures health-related quality of life in people with dementia. The sample consisted of 173 informal carers of people with dementia, aged 29 to 89 years old. Carers were mostly female, White/White British and closely related to the patient. They completed DEMQOL-Proxy (self-administered), EQ-5D-3L (proxy reported about the person with dementia), EQ-5D-3L (self-reported about their own health) and the Zarit Burden Interview. Using well-established methods from classical test theory, we evaluated scale level acceptability, reliability and convergent, discriminant and known-groups validity of DEMQOL-Proxy. DEMQOL-Proxy (self-administered) showed high acceptability (3.5% missing data and 0% scores at floor or ceiling), high internal consistency reliability (α = 0.93) and good convergent and discriminant validity. Amongst others, we found a moderately high correlation with EQ-5D-3L proxy reported (r = 0.52) and low to essentially zero correlations with EQ-5D-3L self-reported (r = 0.20) and carer and patient background variables (r ≤ 0.20). As predicted, DEMQOL-Proxy (self-administered) showed a modest correlation with DEMQOL (r = 0.32). Known-groups differences on health-related quality of life (comparing people with versus people without cognitive impairment) were of moderate effect size (d = 0.38) and in the expected direction. DEMQOL-Proxy (self-administered) has comparable acceptability, reliability and validity with DEMQOL-Proxy (interviewer administered). DEMQOL-Proxy (self-administered) can be used in a wider variety of contexts than its interviewer-administered version, including routine use in busy clinics. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Inter-rater reliability of case-note audit: a systematic review.

    Science.gov (United States)

    Lilford, Richard; Edwards, Alex; Girling, Alan; Hofer, Timothy; Di Tanna, Gian Luca; Petty, Jane; Nicholl, Jon

    2007-07-01

    The quality of clinical care is often assessed by retrospective examination of case-notes (charts, medical records). Our objective was to determine the inter-rater reliability of case-note audit. We conducted a systematic review of the inter-rater reliability of case-note audit. Analysis was restricted to 26 papers reporting comparisons of two or three raters making independent judgements about the quality of care. Sixty-six separate comparisons were possible, since some papers reported more than one measurement of reliability. Mean kappa values ranged from 0.32 to 0.70. These may be inflated due to publication bias. Measured reliabilities were found to be higher for case-note reviews based on explicit, as opposed to implicit, criteria and for reviews that focused on outcome (including adverse effects) rather than process errors. We found an association between kappa and the prevalence of errors (poor quality care), suggesting alternatives such as tetrachoric and polychoric correlation coefficients be considered to assess inter-rater reliability. Comparative studies should take into account the relationship between kappa and the prevalence of the events being measured.

  8. Reliable computer systems.

    Science.gov (United States)

    Wear, L L; Pinkert, J R

    1993-11-01

    In this article, we looked at some decisions that apply to the design of reliable computer systems. We began with a discussion of several terms such as testability, then described some systems that call for highly reliable hardware and software. The article concluded with a discussion of methods that can be used to achieve higher reliability in computer systems. Reliability and fault tolerance in computers probably will continue to grow in importance. As more and more systems are computerized, people will want assurances about the reliability of these systems, and their ability to work properly even when sub-systems fail.

  9. KIT RELIABILITY FOR CONTROLLING THE QUALITY OF OILS IN FOOD FRYING

    Directory of Open Access Journals (Sweden)

    Simeon Oloni Kotchoni

    2012-08-01

    Full Text Available In Benin, West Africa, frying is one of the major ways of cooking. However, the chemical composition of the oil used in the food frying process contains unsaturated fatty acids and other by-products that compromise the oil quality making it toxic and often carcinogenic. The aim of this study was to check the reliability of kits in controlling three frying yams oil quality. The food frying was performed using oil in a discontinuous heating period of 15 min followed by three hours of cooling period for two experimental days. The temperature, and the oil chemical samplings were assessed with the kit every thirty minutes. In addition, selected oil chemical characteristics were determined to quantitatively and qualitatively appreciate the chemical modifications during the fast food versus the rapid food processing methods. Our findings indicate that water and volatile chemical compounds vary significantly for the first day of analysis from 0.18% to 1.6% for groundnut oil; from 0.14% to 1.4% for palm oil and from 0.17% to 1.6% for cotton oils. We detected a decrease of iodine index to 25%; 35.31% and 27.78% for groundnut, palm and cotton oils respectively. However, the peroxide index increases to 55.33%; 61.90% and 57.78% for groundnut, palm and cotton oils respectively. The increases of acid and saponification indices were also observed. Under conjugated effect of water temperature contained in the yam and air contact, the chemical characteristics of oil vary with the frying time. Our results reveal concordance consistent data with both the rapid methods and laboratory data set analysis.

  10. Highly qualified does not equal high quality: A study of urban stakeholders' perceptions of quality in science teaching

    Science.gov (United States)

    Miranda, Rommel Joseph

    By employing qualitative methods, this study sought to determine the perceptions that urban stakeholders hold about what characteristics should distinguish a high school science teacher whom they would consider to demonstrate high quality in science teaching. A maximum variation sample of six science teachers, three school administrators, six parents and six students from a large urban public school district were interviewed using semi-structured, in-depth interview techniques. From these data, a list of observable characteristics which urban stakeholders hold as evidence of high quality in science teaching was generated. Observational techniques were utilized to determine the extent to which six urban high school science teachers, who meet the NCLB Act criteria for being "highly qualified", actually possessed the characteristics which these stakeholders hold as evidence of high quality in science teaching. Constant comparative analysis was used to analyze the data set. The findings suggest that urban stakeholders perceive that a high school science teacher who demonstrates high quality in science teaching should be knowledgeable about their subject matter, their student population, and should be resourceful; should possess an academic background in science and professional experience in science teaching; should exhibit professionalism, a passion for science and teaching, and a dedication to teaching and student learning; should be skillful in planning and preparing science lessons and in organizing the classroom, in presenting the subject matter to students, in conducting a variety of hands-on activities, and in managing a classroom; and should assess whether students complete class goals and objectives, and provide feedback about grades for students promptly. The findings further reveal that some of the urban high school science teachers who were deemed to be "highly qualified", as defined by the NCLB Act, engaged in practices that threatened quality in science

  11. Measuring Passenger Travel Time Reliability using Smartcard Data

    NARCIS (Netherlands)

    Bagherian, M.; Cats, O.; van Oort, N.; Hickman, M

    2016-01-01

    Service reliability is a key performance measure for transit agencies in increasing their service quality and thus ridership. Conventional reliability metrics are established based on vehicle movements and thus do not adequately reflect passenger’s experience. In the past few years, the growing

  12. Reliability of specific physical examination tests for the diagnosis of shoulder pathologies: a systematic review and meta-analysis.

    Science.gov (United States)

    Lange, Toni; Matthijs, Omer; Jain, Nitin B; Schmitt, Jochen; Lützner, Jörg; Kopkow, Christian

    2017-03-01

    Shoulder pain in the general population is common and to identify the aetiology of shoulder pain, history, motion and muscle testing, and physical examination tests are usually performed. The aim of this systematic review was to summarise and evaluate intrarater and inter-rater reliability of physical examination tests in the diagnosis of shoulder pathologies. A comprehensive systematic literature search was conducted using MEDLINE, EMBASE, Allied and Complementary Medicine Database (AMED) and Physiotherapy Evidence Database (PEDro) through 20 March 2015. Methodological quality was assessed using the Quality Appraisal of Reliability Studies (QAREL) tool by 2 independent reviewers. The search strategy revealed 3259 articles, of which 18 finally met the inclusion criteria. These studies evaluated the reliability of 62 test and test variations used for the specific physical examination tests for the diagnosis of shoulder pathologies. Methodological quality ranged from 2 to 7 positive criteria of the 11 items of the QAREL tool. This review identified a lack of high-quality studies evaluating inter-rater as well as intrarater reliability of specific physical examination tests for the diagnosis of shoulder pathologies. In addition, reliability measures differed between included studies hindering proper cross-study comparisons. PROSPERO CRD42014009018. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. Prediction of software operational reliability using testing environment factors

    International Nuclear Information System (INIS)

    Jung, Hoan Sung; Seong, Poong Hyun

    1995-01-01

    A number of software reliability models have been developed to estimate and to predict software reliability. However, there are no established standard models to quantify software reliability. Most models estimate the quality of software in reliability figures such as remaining faults, failure rate, or mean time to next failure at the testing phase, and they consider them ultimate indicators of software reliability. Experience shows that there is a large gap between predicted reliability during development and reliability measured during operation, which means that predicted reliability, or so-called test reliability, is not operational reliability. Customers prefer operational reliability to test reliability. In this study, we propose a method that predicts operational reliability rather than test reliability by introducing the testing environment factor that quantifies the changes in environments

  14. Short-Term and Medium-Term Reliability Evaluation for Power Systems With High Penetration of Wind Power

    DEFF Research Database (Denmark)

    Ding, Yi; Singh, Chanan; Goel, Lalit

    2014-01-01

    reliability evaluation techniques for power systems are well developed. These techniques are more focused on steady-state (time-independent) reliability evaluation and have been successfully applied in power system planning and expansion. In the operational phase, however, they may be too rough......The expanding share of the fluctuating and less predictable wind power generation can introduce complexities in power system reliability evaluation and management. This entails a need for the system operator to assess the system status more accurately for securing real-time balancing. The existing...... an approximation of the time-varying behavior of power systems with high penetration of wind power. This paper proposes a time-varying reliability assessment technique. Time-varying reliability models for wind farms, conventional generating units, and rapid start-up generating units are developed and represented...

  15. Design for High Performance, Low Power, and Reliable 3D Integrated Circuits

    CERN Document Server

    Lim, Sung Kyu

    2013-01-01

    This book describes the design of through-silicon-via (TSV) based three-dimensional integrated circuits.  It includes details of numerous “manufacturing-ready” GDSII-level layouts of TSV-based 3D ICs, developed with tools covered in the book. Readers will benefit from the sign-off level analysis of timing, power, signal integrity, and thermo-mechanical reliability for 3D IC designs.  Coverage also includes various design-for-manufacturability (DFM), design-for-reliability (DFR), and design-for-testability (DFT) techniques that are considered critical to the 3D IC design process. Describes design issues and solutions for high performance and low power 3D ICs, such as the pros/cons of regular and irregular placement of TSVs, Steiner routing, buffer insertion, low power 3D clock routing, power delivery network design and clock design for pre-bond testability. Discusses topics in design-for-electrical-reliability for 3D ICs, such as TSV-to-TSV coupling, current crowding at the wire-to-TSV junction and the e...

  16. Validity and reliability of the Dutch adaptation of the Psoriatic Arthritis Quality of Life (PsAQoL Questionnaire.

    Directory of Open Access Journals (Sweden)

    Freke Wink

    Full Text Available OBJECTIVE: The Psoriatic Arthritis Quality of Life (PsAQoL questionnaire is a disease- specific instrument developed to measure quality of life (QoL in patients with psoriatic arthritis (PsA. The aim of this study was to translate the measure into Dutch and to determine its psychometric properties. METHOD: Translation of the original English PsAQoL into Dutch was performed by bilingual and lay panel. Ten field-test interviews with PsA patients were performed to assess face and content validity. In total, 211 PsA patients were included in a test-retest postal survey to investigate the reliability and construct validity of the Dutch adaptation of the PsAQoL. The PsAQoL, Health Assessment Questionnaire (HAQ and Skindex-17 were administered on two different occasions approximately two weeks apart. RESULTS: The Dutch version of the PsAQoL was found to be relevant, understandable and easy to complete in only a few minutes. It correlated as expected with the HAQ (Spearman's ρ = 0.72 and the 2 subscales of the Skindex-17 (ρ = 0.40 for the psychosocial and ρ = 0.46 for the symptom scale. Furthermore, the measure had good internal consistency (Cronbach's α = 0.92 and test-retest reliability (ρ = 0.89. The PsAQoL was able to define groups of patients based on self-reported general health status, self-reported severity of PsA and flare of arthritis. Duration of PsA did not influence PsAQoL scores. CONCLUSIONS: The Dutch version of the PsAQoL is a valid and reliable questionnaire suitable for use in clinical or research settings to asses PsA-specific QoL.

  17. Fast High-Quality Noise

    DEFF Research Database (Denmark)

    Frisvad, Jeppe Revall; Wyvill, Geoff

    2007-01-01

    At the moment the noise functions available in a graphics programmer's toolbox are either slow to compute or they involve grid-line artifacts making them of lower quality. In this paper we present a real-time noise computation with no grid-line artifacts or other regularity problems. In other words......, we put a new tool in the box that computes fast high-quality noise. In addition to being free of artifacts, the noise we present does not rely on tabulated data (everything is computed on the fly) and it is easy to adjust quality vs. quantity for the noise. The noise is based on point rendering (like...... spot noise), but it extends to more than two dimensions. The fact that it is based on point rendering makes art direction of the noise much easier....

  18. Gearbox Reliability Collaborative Investigation of High-Speed-Shaft Bearing Loads

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Guo, Yi [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-06-01

    The loads and contact stresses in the bearings of the high speed shaft section of the Gearbox Reliability Collaborative gearbox are examined in this paper. The loads were measured though strain gauges installed on the bearing outer races during dynamometer testing of the gearbox. Loads and stresses were also predicted with a simple analytical model and higher-fidelity commercial models. The experimental data compared favorably to each model, and bearing stresses were below thresholds for contact fatigue and axial cracking.

  19. power system reliability in supplying nuclear reactors

    International Nuclear Information System (INIS)

    Gad, M.M.M.

    2007-01-01

    this thesis presents a simple technique for deducing minimal cut set (MCS) from the defined minimal path set (MPS) of generic distribution system and this technique have been used to evaluate the basic reliability indices of Egypt's second research reactor (ETRR-2) electrical distribution network. the alternative system configurations are then studied to evaluate their impact on service reliability. the proposed MCS approach considers both sustained and temporary outage. the temporary outage constitutes an important parameter in characterizing the system reliability indices for critical load point in distribution system. it is also consider the power quality impact on the reliability indices

  20. Influence of reliability of the relay protection to the whole reliability of electric power systems

    International Nuclear Information System (INIS)

    Stojanovski, Ljupcho I.

    2001-01-01

    The influence of the reliability of the elements of relay protection up today analyses of the reliability on electric power systems, very rare has been taken into consideration, in other words, in these analyses it is assumed that the reliability of the protection has value one. In this work an attempt is that through modelling of individual types of protection of the elements of high-voltage systems to make calculation to the influence of the reliability of the relay protection on the total reliability of the high-voltage systems.(Author)

  1. Assuring quality in high-consequence engineering

    Energy Technology Data Exchange (ETDEWEB)

    Hoover, Marcey L.; Kolb, Rachel R.

    2014-03-01

    In high-consequence engineering organizations, such as Sandia, quality assurance may be heavily dependent on staff competency. Competency-dependent quality assurance models are at risk when the environment changes, as it has with increasing attrition rates, budget and schedule cuts, and competing program priorities. Risks in Sandia's competency-dependent culture can be mitigated through changes to hiring, training, and customer engagement approaches to manage people, partners, and products. Sandia's technical quality engineering organization has been able to mitigate corporate-level risks by driving changes that benefit all departments, and in doing so has assured Sandia's commitment to excellence in high-consequence engineering and national service.

  2. How reliable are case formulations? A systematic literature review.

    Science.gov (United States)

    Flinn, Lucinda; Braham, Louise; das Nair, Roshan

    2015-09-01

    This systematic literature review investigated the inter-rater and test-retest reliability of case formulations. We considered the reliability of case formulations across a range of theoretical modalities and the general quality of the primary research studies. A systematic search of five electronic databases was conducted in addition to reference list trawling to find studies that assessed the reliability of case formulation. This yielded 18 studies for review. A methodological quality assessment tool was developed to assess the quality of studies, which informed interpretation of the findings. Results indicated inter-rater reliability mainly ranging from slight (.1-.4) to substantial (.81-1.0). Some studies highlighted that training and increased experience led to higher levels of agreement. In general, psychodynamic formulations appeared to generate somewhat increased levels of reliability than cognitive or behavioural formulations; however, these studies also included methods that may have served to inflate reliability, for example, pooling the scores of judges. Only one study investigated the test-retest reliability of case formulations yielding support for the stability of formulations over a 3-month period. Reliability of case formulations is varied across a range of theoretical modalities, but can be improved; however, further research is required to strengthen our conclusions. Clinical implications: The findings from the review evidence some support for case formulation being congruent with the scientist-practitioner approach. The reliability of case formulation is likely to be improved through training and clinical experience. Limitations: The broad inclusion criteria may have introduced heterogeneity into the sample, which may have affected the results. Studies reviewed were limited to peer-reviewed journal articles written in the English language, which may represent a source of publication and selection bias. © 2014 The British Psychological Society.

  3. Reliability Analysis of Fatigue Fracture of Wind Turbine Drivetrain Components

    DEFF Research Database (Denmark)

    Berzonskis, Arvydas; Sørensen, John Dalsgaard

    2016-01-01

    in the volume of the casted ductile iron main shaft, on the reliability of the component. The probabilistic reliability analysis conducted is based on fracture mechanics models. Additionally, the utilization of the probabilistic reliability for operation and maintenance planning and quality control is discussed....

  4. Approach for an integral power transformer reliability model

    NARCIS (Netherlands)

    Schijndel, van A.; Wouters, P.A.A.F.; Steennis, E.F.; Wetzer, J.M.

    2012-01-01

    In electrical power transmission and distribution networks power transformers represent a crucial group of assets both in terms of reliability and investments. In order to safeguard the required quality at acceptable costs, decisions must be based on a reliable forecast of future behaviour. The aim

  5. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    The practice of nuclear diagnostic imaging requires an appropriate quality assurance program to attain high standards of efficiency and reliability. The International Atomic Energy Agency defines the term quality assurance as ''the closeness with which the outcome of a given procedure approaches some ideal, free from all errors and artifacts.'' The term quality control is used in reference to the specific measures taken to ensure that one particular aspect of the procedure is satisfactory. Therefore, quality assurance is a hospital-wide concept that should involve all aspects of clinical practice. Quality control is concerned with the submission of requests for procedures; the scheduling of patients; the preparation and dispensing of radiopharmaceuticals; the protection of patients, staff, and the general public against radiation hazards and accidents caused by radioactive materials or by faulty equipment; the setting up, use, and maintenance of electronic instruments; the methodology of the actual procedures; the analysis and interpretation of data; the reporting of results; and, finally, the keeping of records. The chapter discusses each of these areas

  6. Reliable implementation of evidence: a qualitative study of antenatal corticosteroid administration in Ohio hospitals.

    Science.gov (United States)

    Kaplan, Heather C; Sherman, Susan N; Cleveland, Charlena; Goldenhar, Linda M; Lannon, Carole M; Bailit, Jennifer L

    2016-03-01

    Antenatal corticosteroids (ANCS) reduce complications of preterm birth; however, not all eligible women receive them. Many hospitals and providers do not have the right processes and conditions to enable ANCS administration with high reliability. The objective of this study was to understand conditions that enable delivery of ANCS with high reliability among hospitals participating in an Ohio Perinatal Quality Collaborative (OPQC) ANCS project. We conducted focus groups and semistructured interviews with members of the OPQC project team (n=27) and other care providers (n=70) using a purposeful sample of 6 sites involved in the OPQC ANCS project. Participants including nurses (n=57), attending obstetricians (n=17), physician trainees (n=21) and certified nurse midwives (n=2) were asked to reflect on their experiences and to identify factors contributing to optimal use of ANCS. Focus groups and interviews were transcribed verbatim and were analysed by a multidisciplinary team using an iterative approach that combined inductive and deductive methods to identify and categorise themes. Six major themes supporting reliable implementation of ANCS at these hospitals emerged including: (1) presence of a high reliability culture, (2) processes that emphasise high reliability, (3) timely and efficient administration process, (4) multiple disciplines are involved, (5) evidence of benefit supports ANCS use and (6) benefit is recognised at all levels of the care team. Our findings identify the key processes and supports needed to ensure delivery of ASCS with high reliability and are reinforced by implementation and reliability science. They are useful for foundation of the successful implementation of other evidence-based practices at high levels of reliability. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. Reliability of CGA/LGA/HDI Package Board/Assembly (Final Report)

    Science.gov (United States)

    Ghaffaroam. Reza

    2014-01-01

    Package manufacturers are now offering commercial-off-the-shelf column grid array (COTS CGA) packaging technologies in high-reliability versions. Understanding the process and quality assurance (QA) indicators for reliability are important for low-risk insertion of these advanced electronics packages. The previous reports, released in January of 2012 and January of 2013, presented package test data, assembly information, and reliability evaluation by thermal cycling for CGA packages with 1752, 1517, 1509, and 1272 inputs/outputs (I/Os) and 1-mm pitch. It presented the thermal cycling (-55C either 100C or 125C) test results for up to 200 cycles. This report presents up to 500 thermal cycles with quality assurance and failure analysis evaluation represented by optical photomicrographs, 2D real time X-ray images, dye-and-pry photomicrographs, and optical/scanning electron Microscopy (SEM) cross-sectional images. The report also presents assembly challenge using reflowing by either vapor phase or rework station of CGA and land grid array (LGA) versions of three high I/O packages both ceramic and plastic configuration. A new test vehicle was designed having high density interconnect (HDI) printed circuit board (PCB) with microvia-in-pad to accommodate both LGA packages as well as a large number of fine pitch ball grid arrays (BGAs). The LGAs either were assembled onto HDI PCB as an LGA or were solder paste print and reflow first to form solder dome on pads before assembly. Both plastic BGAs with 1156 I/O and ceramic LGAs were assembled. It also presented the X-ray inspection results as well as failures due to 200 thermal cycles. Lessons learned on assembly of ceramic LGAs are also presented.

  8. Designing and Assessing the Validity and Reliability of the Hospital Readiness Assessment Tools to Conducting Quality Improvement Program

    Directory of Open Access Journals (Sweden)

    Kamal Gholipoor

    2016-09-01

    Full Text Available Background and objectives : Identifying the readiness of hospital and its strengths and weaknesses can be useful in developing appropriate planning and situation analyses and management to getting effective in clinical audit programs. The aim of this study was to design and assess the validity of the Hospital Readiness Assessment Tools to conduct quality improvement and clinical audit programs. Material and Methods: In this study, based on the results of a systematic review of literature, an initial questionnaire with 77 items was designed. Questionnaire content validity was reviewed by experts in the field of hospital management and quality improvement in Tabriz University of Medical Sciences. For this purpose, 20 questionnaires were sent to experts. Finally, 15 participants returned completed questionnaire. Questionnaire validity was reviewed and confirmed based on Content Validity Index and Content Validity Ratio. Questionnaire reliability was confirmed based on Cronbach's alpha index (α = 0.96 in a pilot study by participation of 30 hospital managers. Results: The results showed that the final questionnaire contains 54 questions as nine category as: data and information (9 items, teamwork (12 questions, resources (5 questions, patient and education (5, intervention design and implementation (5 questions, clinical audit management (4 questions, human resources (6 questions, evidence and standard (4 items and evaluation and feedback (4 items. The final questionnaire content validity index was 0.91 and final questionnaire Cronbach's alpha coefficient was 0.96. Conclusion: Considering the relative good validity and reliability of the designed tool in this study, it appears that the questionnaire can be used to identify and assess the readiness of hospitals for quality improvement and clinical audit program implementation

  9. A high throughput DNA extraction method with high yield and quality

    Directory of Open Access Journals (Sweden)

    Xin Zhanguo

    2012-07-01

    Full Text Available Abstract Background Preparation of large quantity and high quality genomic DNA from a large number of plant samples is a major bottleneck for most genetic and genomic analyses, such as, genetic mapping, TILLING (Targeting Induced Local Lesion IN Genome, and next-generation sequencing directly from sheared genomic DNA. A variety of DNA preparation methods and commercial kits are available. However, they are either low throughput, low yield, or costly. Here, we describe a method for high throughput genomic DNA isolation from sorghum [Sorghum bicolor (L. Moench] leaves and dry seeds with high yield, high quality, and affordable cost. Results We developed a high throughput DNA isolation method by combining a high yield CTAB extraction method with an improved cleanup procedure based on MagAttract kit. The method yielded large quantity and high quality DNA from both lyophilized sorghum leaves and dry seeds. The DNA yield was improved by nearly 30 fold with 4 times less consumption of MagAttract beads. The method can also be used in other plant species, including cotton leaves and pine needles. Conclusion A high throughput system for DNA extraction from sorghum leaves and seeds was developed and validated. The main advantages of the method are low cost, high yield, high quality, and high throughput. One person can process two 96-well plates in a working day at a cost of $0.10 per sample of magnetic beads plus other consumables that other methods will also need.

  10. Reliable high-power diode lasers: thermo-mechanical fatigue aspects

    Science.gov (United States)

    Klumel, Genady; Gridish, Yaakov; Szafranek, Igor; Karni, Yoram

    2006-02-01

    High power water-cooled diode lasers are finding increasing demand in biomedical, cosmetic and industrial applications, where repetitive cw (continuous wave) and pulsed cw operation modes are required. When operating in such modes, the lasers experience numerous complete thermal cycles between "cold" heat sink temperature and the "hot" temperature typical of thermally equilibrated cw operation. It is clearly demonstrated that the main failure mechanism directly linked to repetitive cw operation is thermo-mechanical fatigue of the solder joints adjacent to the laser bars, especially when "soft" solders are used. Analyses of the bonding interfaces were carried out using scanning electron microscopy. It was observed that intermetallic compounds, formed already during the bonding process, lead to the solders fatigue both on the p- and n-side of the laser bar. Fatigue failure of solder joints in repetitive cw operation reduces useful lifetime of the stacks to hundreds hours, in comparison with more than 10,000 hours lifetime typically demonstrated in commonly adopted non-stop cw reliability testing programs. It is shown, that proper selection of package materials and solders, careful design of fatigue sensitive parts and burn-in screening in the hard pulse operation mode allow considerable increase of lifetime and reliability, without compromising the device efficiency, optical power density and compactness.

  11. Efficient and reliable 3D dose quality assurance for IMRT by combining independent dose calculations with measurements

    International Nuclear Information System (INIS)

    Visser, R.; Wauben, D. J. L.; Godart, J.; Langendijk, J. A.; Veld, A. A. van't; Korevaar, E. W.; Groot, M. de

    2013-01-01

    Purpose: Advanced radiotherapy treatments require appropriate quality assurance (QA) to verify 3D dose distributions. Moreover, increase in patient numbers demand efficient QA-methods. In this study, a time efficient method that combines model-based QA and measurement-based QA was developed; i.e., the hybrid-QA. The purpose of this study was to determine the reliability of the model-based QA and to evaluate time efficiency of the hybrid-QA method. Methods: Accuracy of the model-based QA was determined by comparison of COMPASS calculated dose with Monte Carlo calculations for heterogeneous media. In total, 330 intensity modulated radiation therapy (IMRT) treatment plans were evaluated based on the mean gamma index (GI) with criteria of 3%/3mm and classification of PASS (GI ≤ 0.4), EVAL (0.4 0.6), and FAIL (GI ≥ 0.6). Agreement between model-based QA and measurement-based QA was determined for 48 treatment plans, and linac stability was verified for 15 months. Finally, time efficiency improvement of the hybrid-QA was quantified for four representative treatment plans. Results: COMPASS calculated dose was in agreement with Monte Carlo dose, with a maximum error of 3.2% in heterogeneous media with high density (2.4 g/cm 3 ). Hybrid-QA results for IMRT treatment plans showed an excellent PASS rate of 98% for all cases. Model-based QA was in agreement with measurement-based QA, as shown by a minimal difference in GI of 0.03 ± 0.08. Linac stability was high with an average GI of 0.28 ± 0.04. The hybrid-QA method resulted in a time efficiency improvement of 15 min per treatment plan QA compared to measurement-based QA. Conclusions: The hybrid-QA method is adequate for efficient and accurate 3D dose verification. It combines time efficiency of model-based QA with reliability of measurement-based QA and is suitable for implementation within any radiotherapy department.

  12. Reliability and maintainability data acquisition in equipment development tests

    International Nuclear Information System (INIS)

    Haire, M.J.; Gift, E.H.

    1983-10-01

    The need for collection of reliability, maintainability, and availability data adds a new dimension to the data acquisition requirements of equipment development tests. This report describes the reliability and maintainability data that are considered necessary to ensure that sufficient and high quality data exist for a comprehensive, quantitative evaluation of equipment and system availability. These necessary data are presented as a set of data collection forms. Three data acquisition forms are discussed: an inventory and technical data form, which is filed by the design engineer when the design is finished or the equipment is received; an event report form, which is completed by the senior test operator at each shutdown; and a maintainability report, which is a collaborative effort between senior operators and lead engineers and is completed on restart. In addition, elements of a reliability, maintainability evaluation program are described. Emphasis is placed on the role of data, its storage, and use in such a program

  13. Taguchi Approach to Design Optimization for Quality and Cost: An Overview

    Science.gov (United States)

    Unal, Resit; Dean, Edwin B.

    1990-01-01

    Calibrations to existing cost of doing business in space indicate that to establish human presence on the Moon and Mars with the Space Exploration Initiative (SEI) will require resources, felt by many, to be more than the national budget can afford. In order for SEI to succeed, we must actually design and build space systems at lower cost this time, even with tremendous increases in quality and performance requirements, such as extremely high reliability. This implies that both government and industry must change the way they do business. Therefore, new philosophy and technology must be employed to design and produce reliable, high quality space systems at low cost. In recognizing the need to reduce cost and improve quality and productivity, Department of Defense (DoD) and National Aeronautics and Space Administration (NASA) have initiated Total Quality Management (TQM). TQM is a revolutionary management strategy in quality assurance and cost reduction. TQM requires complete management commitment, employee involvement, and use of statistical tools. The quality engineering methods of Dr. Taguchi, employing design of experiments (DOE), is one of the most important statistical tools of TQM for designing high quality systems at reduced cost. Taguchi methods provide an efficient and systematic way to optimize designs for performance, quality, and cost. Taguchi methods have been used successfully in Japan and the United States in designing reliable, high quality products at low cost in such areas as automobiles and consumer electronics. However, these methods are just beginning to see application in the aerospace industry. The purpose of this paper is to present an overview of the Taguchi methods for improving quality and reducing cost, describe the current state of applications and its role in identifying cost sensitive design parameters.

  14. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring

    OpenAIRE

    Amale Ankhili; Xuyuan Tao; Cédric Cochrane; David Coulon; Vladan Koncar

    2018-01-01

    A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The ...

  15. Concrete Waste Recycling Process for High Quality Aggregate

    International Nuclear Information System (INIS)

    Ishikura, Takeshi; Fujii, Shin-ichi

    2008-01-01

    Large amount of concrete waste generates during nuclear power plant (NPP) dismantling. Non-contaminated concrete waste is assumed to be disposed in a landfill site, but that will not be the solution especially in the future, because of decreasing tendency of the site availability and natural resources. Concerning concrete recycling, demand for roadbeds and backfill tends to be less than the amount of dismantled concrete generated in a single rural site, and conventional recycled aggregate is limited of its use to non-structural concrete, because of its inferior quality to ordinary natural aggregate. Therefore, it is vital to develop high quality recycled aggregate for general uses of dismantled concrete. If recycled aggregate is available for high structural concrete, the dismantling concrete is recyclable as aggregate for industry including nuclear field. Authors developed techniques on high quality aggregate reclamation for large amount of concrete generated during NPP decommissioning. Concrete of NPP buildings has good features for recycling aggregate; large quantity of high quality aggregate from same origin, record keeping of the aggregate origin, and little impurities in dismantled concrete such as wood and plastics. The target of recycled aggregate in this development is to meet the quality criteria for NPP concrete as prescribed in JASS 5N 'Specification for Nuclear Power Facility Reinforced Concrete' and JASS 5 'Specification for Reinforced Concrete Work'. The target of recycled aggregate concrete is to be comparable performance with ordinary aggregate concrete. The high quality recycled aggregate production techniques are assumed to apply for recycling for large amount of non-contaminated concrete. These techniques can also be applied for slightly contaminated concrete dismantled from radiological control area (RCA), together with free release survey. In conclusion: a technology on dismantled concrete recycling for high quality aggregate was developed

  16. DJ-1 is a reliable serum biomarker for discriminating high-risk endometrial cancer.

    Science.gov (United States)

    Di Cello, Annalisa; Di Sanzo, Maddalena; Perrone, Francesca Marta; Santamaria, Gianluca; Rania, Erika; Angotti, Elvira; Venturella, Roberta; Mancuso, Serafina; Zullo, Fulvio; Cuda, Giovanni; Costanzo, Francesco

    2017-06-01

    New reliable approaches to stratify patients with endometrial cancer into risk categories are highly needed. We have recently demonstrated that DJ-1 is overexpressed in endometrial cancer, showing significantly higher levels both in serum and tissue of patients with high-risk endometrial cancer compared with low-risk endometrial cancer. In this experimental study, we further extended our observation, evaluating the role of DJ-1 as an accurate serum biomarker for high-risk endometrial cancer. A total of 101 endometrial cancer patients and 44 healthy subjects were prospectively recruited. DJ-1 serum levels were evaluated comparing cases and controls and, among endometrial cancer patients, between high- and low-risk patients. The results demonstrate that DJ-1 levels are significantly higher in cases versus controls and in high- versus low-risk patients. The receiver operating characteristic curve analysis shows that DJ-1 has a very good diagnostic accuracy in discriminating endometrial cancer patients versus controls and an excellent accuracy in distinguishing, among endometrial cancer patients, low- from high-risk cases. DJ-1 sensitivity and specificity are the highest when high- and low-risk patients are compared, reaching the value of 95% and 99%, respectively. Moreover, DJ-1 serum levels seem to be correlated with worsening of the endometrial cancer grade and histotype, making it a reliable tool in the preoperative decision-making process.

  17. In-house quality audit and benefits of some quality control procedures in the quality assurance of TL dosimetry system at NRPB

    International Nuclear Information System (INIS)

    Dutt, J.C.

    1993-01-01

    A number of Quality Control (QC) procedures have been introduced into the running and operation of the NRPB personal monitoring services. Those described here apply to the whole-body TL dosimetry system. These QC procedures comprise Quality Assurance (QA) of incoming raw materials and equipment, reader stabilisation, daily, routine and periodic QA checks on all phases of the service. In-house quality audit, periodic internal and external 'blind QA checks' on the dosimetry system as a whole have assured the continuing high quality and reliability of the NRPB TL dosimetry service for assessing body and skin doses of radiation workers from external photon and beta radiations. (author)

  18. Quality and Reliability of Large-Eddy Simulations

    CERN Document Server

    Meyers, Johan; Sagaut, Pierre

    2008-01-01

    Computational resources have developed to the level that, for the first time, it is becoming possible to apply large-eddy simulation (LES) to turbulent flow problems of realistic complexity. Many examples can be found in technology and in a variety of natural flows. This puts issues related to assessing, assuring, and predicting the quality of LES into the spotlight. Several LES studies have been published in the past, demonstrating a high level of accuracy with which turbulent flow predictions can be attained, without having to resort to the excessive requirements on computational resources imposed by direct numerical simulations. However, the setup and use of turbulent flow simulations requires a profound knowledge of fluid mechanics, numerical techniques, and the application under consideration. The susceptibility of large-eddy simulations to errors in modelling, in numerics, and in the treatment of boundary conditions, can be quite large due to nonlinear accumulation of different contributions over time, ...

  19. Reliability of Oronasal Fistula Classification.

    Science.gov (United States)

    Sitzman, Thomas J; Allori, Alexander C; Matic, Damir B; Beals, Stephen P; Fisher, David M; Samson, Thomas D; Marcus, Jeffrey R; Tse, Raymond W

    2018-01-01

    Objective Oronasal fistula is an important complication of cleft palate repair that is frequently used to evaluate surgical quality, yet reliability of fistula classification has never been examined. The objective of this study was to determine the reliability of oronasal fistula classification both within individual surgeons and between multiple surgeons. Design Using intraoral photographs of children with repaired cleft palate, surgeons rated the location of palatal fistulae using the Pittsburgh Fistula Classification System. Intrarater and interrater reliability scores were calculated for each region of the palate. Participants Eight cleft surgeons rated photographs obtained from 29 children. Results Within individual surgeons reliability for each region of the Pittsburgh classification ranged from moderate to almost perfect (κ = .60-.96). By contrast, reliability between surgeons was lower, ranging from fair to substantial (κ = .23-.70). Between-surgeon reliability was lowest for the junction of the soft and hard palates (κ = .23). Within-surgeon and between-surgeon reliability were almost perfect for the more general classification of fistula in the secondary palate (κ = .95 and κ = .83, respectively). Conclusions This is the first reliability study of fistula classification. We show that the Pittsburgh Fistula Classification System is reliable when used by an individual surgeon, but less reliable when used among multiple surgeons. Comparisons of fistula occurrence among surgeons may be subject to less bias if they use the more general classification of "presence or absence of fistula of the secondary palate" rather than the Pittsburgh Fistula Classification System.

  20. Reliability program plan for the Isotope Brayton Ground Demonstration System (phase I)

    International Nuclear Information System (INIS)

    1975-01-01

    The reliability and quality assurance organizational relationships, the methods to be used, the tasks to be completed, and the documentation to be published are presented. The total program is intended to provide the necessary reliability and quality assurance associated with the design, fabrication, and testing of the GDS. It is consistent with the general objectives of the ERDA Quality Assurance (QA) program requirements document ''SNS-1'' dated April 1972 and reliability program requirements document ''SNS-2'' dated 17 June 1974 but has been specifically modified for the GDS with the intent of establishing background data for the subsequent Phase II effort

  1. Reliability in individual monitoring service.

    Science.gov (United States)

    Mod Ali, N

    2011-03-01

    As a laboratory certified to ISO 9001:2008 and accredited to ISO/IEC 17025, the Secondary Standard Dosimetry Laboratory (SSDL)-Nuclear Malaysia has incorporated an overall comprehensive system for technical and quality management in promoting a reliable individual monitoring service (IMS). Faster identification and resolution of issues regarding dosemeter preparation and issuing of reports, personnel enhancement, improved customer satisfaction and overall efficiency of laboratory activities are all results of the implementation of an effective quality system. Review of these measures and responses to observed trends provide continuous improvement of the system. By having these mechanisms, reliability of the IMS can be assured in the promotion of safe behaviour at all levels of the workforce utilising ionising radiation facilities. Upgradation of in the reporting program through a web-based e-SSDL marks a major improvement in Nuclear Malaysia's IMS reliability on the whole. The system is a vital step in providing a user friendly and effective occupational exposure evaluation program in the country. It provides a higher level of confidence in the results generated for occupational dose monitoring of the IMS, thus, enhances the status of the radiation protection framework of the country.

  2. Introduction of quality management (1973)

    International Nuclear Information System (INIS)

    1973-03-01

    This book deals with quality management, which indicates company activity, function and system, quality and price, basic, technology, production, policy and train of quality management, data experience and sense, data for analysis, about experiment plan, method for analysis, what is quality? standardization for process control, quality and check, education plan, practice of education, check of the result and reliability and quality management and assurance of reliability.

  3. Reliability of supply of switchgear for auxiliary low voltage in substations extra high voltage to high voltage

    Directory of Open Access Journals (Sweden)

    Perić Dragoslav M.

    2015-01-01

    Full Text Available Switchgear for auxiliary low voltage in substations (SS of extra high voltages (EHV to high voltage (HV - SS EHV/HV kV/kV is of special interest for the functioning of these important SS, as it provides a supply for system of protection and other vital functions of SS. The article addresses several characteristic examples involving MV lines with varying degrees of independence of their supply, and the possible application of direct transformation EHV/LV through special voltage transformers. Auxiliary sources such as inverters and diesel generators, which have limited power and expensive energy, are also used for the supply of switchgear for auxiliary low voltage. Corresponding reliability indices are calculated for all examples including mean expected annual engagement of diesel generators. The applicability of certain solutions of switchgear for auxiliary low voltage SS EHV/HV, taking into account their reliability, feasibility and cost-effectiveness is analyzed too. In particular, the analysis of applications of direct transformation EHV/LV for supply of switchgear for auxiliary low voltage, for both new and existing SS EHV/HV.

  4. MEMS reliability: coming of age

    Science.gov (United States)

    Douglass, Michael R.

    2008-02-01

    In today's high-volume semiconductor world, one could easily take reliability for granted. As the MOEMS/MEMS industry continues to establish itself as a viable alternative to conventional manufacturing in the macro world, reliability can be of high concern. Currently, there are several emerging market opportunities in which MOEMS/MEMS is gaining a foothold. Markets such as mobile media, consumer electronics, biomedical devices, and homeland security are all showing great interest in microfabricated products. At the same time, these markets are among the most demanding when it comes to reliability assurance. To be successful, each company developing a MOEMS/MEMS device must consider reliability on an equal footing with cost, performance and manufacturability. What can this maturing industry learn from the successful development of DLP technology, air bag accelerometers and inkjet printheads? This paper discusses some basic reliability principles which any MOEMS/MEMS device development must use. Examples from the commercially successful and highly reliable Digital Micromirror Device complement the discussion.

  5. Performance and reliability of the Y-Balance TestTM in high school athletes.

    Science.gov (United States)

    Smith, Laura J; Creps, James R; Bean, Ryan; Rodda, Becky; Alsalaheen, Bara

    2017-11-07

    Lower extremity injuries account for 32.9% of the overall injuries in high school athletes. Previous research has suggested that asymmetry greater than 4cm using the Y-Balance TestTM Lower Quarter (YBT-LQ) in the anterior direction is predictive of non- contact injuries in adults and collegiate athletes. The prevalence of asymmetries or abnormal YBT-LQ performance is not well documented for adolescents. The primary purposes of this study are: 1) to characterize the prevalence of YBT-LQ asymmetries and performance in a cross-sectional sample of adolescents, 2) to examine possible differences in performance on the YBT-LQ between male and female adolescents, and 3) to describe the test-retest reliability of the YBT-LQ in a subsample of adolescents. Observational cross-sectional study. High-school athletes completed the YBT-LQ as main outcome measure. 51 male, 59 female high-school athletes participated in this study. Asymmetries greater than 4cm in the posteromedial (PM) reach direction were most prevalent for male (54.9%) and female (50.8%) participants. Females presented with slightly higher composite scores. Good reliability (ICC = 0.89) was found for the anterior (ANT) direction, and moderate reliability with 0.76 for posterolateral (PL) and 0.63 for PM directions. The MDC95 for the ANT direction was 6% and 12% for both the PL and PM directions. The YBT-LQ performance can be beneficial in assessing recovery in an injured extremity compared to the other limb. However, due to the large MDC95, noted in the PM and PL directions, the differences between sequential testing cannot be attributed to true change in balance unless they exceed the MDC95. In this study, 79% of the athletes presented with at least one asymmetry in YBT-LQ reach distances. Moderate reliability in the PL and PM directions warrants reexamination of the definition of asymmetry in these directions.

  6. The reliability of the software of the digital control system Nuclear Advantage

    International Nuclear Information System (INIS)

    Graae, T.; Engdahl, L.

    1996-01-01

    The ABB nuclear power control system Nuclear Advantage is a truly integrated control system. The integration of process control and safety control aims at achieving a common operator interface in order to simplify and thus improve control room ergonomics. The challenge is to design an integrated control system and at the same time ensure the functional separation between the independent safety subsystems as well as between the safety and the conventional sections. Software reliability is discussed and illustrated by statistical test results. It has proved to be a hundred times better than the reliability of the high-quality hardware. (orig.) [de

  7. Improving the safety and reliability of Monju

    International Nuclear Information System (INIS)

    Itou, Kazumoto; Maeda, Hiroshi; Moriyama, Masatoshi

    1998-01-01

    Comprehensive safety review has been performed at Monju to determine why the Monju secondary sodium leakage accident occurred. We investigated how to improve the situation based on the results of the safety review. The safety review focused on five aspects of whether the facilities for dealing with the sodium leakage accident were adequate: the reliability of the detection method, the reliability of the method for preventing the spread of the sodium leakage accident, whether the documented operating procedures are adequate, whether the quality assurance system, program, and actions were properly performed and so on. As a result, we established for Monju a better method of dealing with sodium leakage accidents, rapid detection of sodium leakage, improvement of sodium drain facilities, and way to reduce damage to Monju systems after an accident. We also improve the operation procedures and quality assurance actions to increase the safety and reliability of Monju. (author)

  8. A quantitative calculation for software reliability evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young-Jun; Lee, Jang-Soo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    To meet these regulatory requirements, the software used in the nuclear safety field has been ensured through the development, validation, safety analysis, and quality assurance activities throughout the entire process life cycle from the planning phase to the installation phase. A variety of activities, such as the quality assurance activities are also required to improve the quality of a software. However, there are limitations to ensure that the quality is improved enough. Therefore, the effort to calculate the reliability of the software continues for a quantitative evaluation instead of a qualitative evaluation. In this paper, we propose a quantitative calculation method for the software to be used for a specific operation of the digital controller in an NPP. After injecting random faults in the internal space of a developed controller and calculating the ability to detect the injected faults using diagnostic software, we can evaluate the software reliability of a digital controller in an NPP. We tried to calculate the software reliability of the controller in an NPP using a new method that differs from a traditional method. It calculates the fault detection coverage after injecting the faults into the software memory space rather than the activity through the life cycle process. We attempt differentiation by creating a new definition of the fault, imitating the software fault using the hardware, and giving a consideration and weights for injection faults.

  9. The Cambridge Otology Quality of Life Questionnaire: an otology-specific patient-recorded outcome measure. A paper describing the instrument design and a report of preliminary reliability and validity.

    Science.gov (United States)

    Martin, T P C; Moualed, D; Paul, A; Ronan, N; Tysome, J R; Donnelly, N P; Cook, R; Axon, P R

    2015-04-01

    The Cambridge Otology Quality of Life Questionnaire (COQOL) is a patient-recorded outcome measurement (PROM) designed to quantify the quality of life of patients attending otology clinics. Item-reduction model. A systematically designed long-form version (74 items) was tested with patient focus groups before being presented to adult otology patients (n. 137). Preliminary item analysis tested reliability, reducing the COQOL to 24 questions. This was then presented in conjunction with the SF-36 (V1) questionnaire to a total of 203 patients. Subsequently, these were re-presented at T + 3 months, and patients recorded whether they felt their condition had improved, deteriorated or remained the same. Non-responders were contacted by post. A correlation between COQOL scores and patient perception of change was examined to analyse content validity. Teaching hospital and university psychology department. Adult patients attending otology clinics with a wide range of otological conditions. Item reliability measured by item–total correlation, internal consistency and test– retest reliability. Validity measured by correlation between COQOL scores and patient-reported symptom change. Reliability: the COQOL showed excellent internal consistency at both initial presentation (a = 0.90) and 3 months later (a = 0.93). Validity: One-way analysis of variance showed a significant difference between groups reporting change and those reporting no change in quality of life (F(2, 80) = 5.866, P < 0.01). The COQOL is the first otology-specific PROM. Initial studies demonstrate excellent reliability and encouraging preliminary criterion validity: further studies will allow a deeper validation of the instrument.

  10. Standard high-reliability integrated circuit logic packaging. [for deep space tracking stations

    Science.gov (United States)

    Slaughter, D. W.

    1977-01-01

    A family of standard, high-reliability hardware used for packaging digital integrated circuits is described. The design transition from early prototypes to production hardware is covered and future plans are discussed. Interconnections techniques are described as well as connectors and related hardware available at both the microcircuit packaging and main-frame level. General applications information is also provided.

  11. Effect of forage quality in faeces from different ruminant species fed high and low quality forage

    DEFF Research Database (Denmark)

    Jalali, A R; Nørgaard, P; Nielsen, M O

    2010-01-01

    Effect of forage quality in faeces from different ruminant species fed high and low quality forage......Effect of forage quality in faeces from different ruminant species fed high and low quality forage...

  12. Octennial History of the Development and Quality of High-Efficiency Filters for the US Atomic Energy Program

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, H. [United States Atomic Energy Commission, Washington, DC (United States)

    1968-12-15

    Two facilities are operated for the US atomic energy commission in its program to ensure the uniform quality of commercially manufactured high-efficiency particulate filters. the filter-testing program was started in january 1960 after it was realized that the commercial fire-resistant product incorporated deficiencies of manufacture. the record of testing for quality assurance by the two facilities and an analysis of factors governing the quality of filters are presented. the analysis is complemented with a description of efforts, made in the course of the filter testing, to improve the design of the filter for efficiency and reliability. the fire-resistant (hepa) filter of 1959 was inadequate. the inadequacy of the filter, now judged by reflection, was brought about by the intensive accelerated efforts to replace and preclude, wherever possible in the US atomic energy program, use of filters made of combustible materials. this desire for fire resistance of filters has proliferated widely among other members of the international atomic energy family. the intensive AEC effort caused US industry to produce filters of fire-resistant design but without the opportunity for development of manufacturing technology adequate for ensuring reliability of the filter. the state of the fire-resistant filter today is in sharp contrast to the 1959 filter. the testing program, coupled with a program for continuing improvement of the filter, has resulted in the effective removal of radioactive aerosols at atomic energy installations on a consistent and dependable basis. (author)

  13. Designing high availability systems DFSS and classical reliability techniques with practical real life examples

    CERN Document Server

    Taylor, Zachary

    2014-01-01

    A practical, step-by-step guide to designing world-class, high availability systems using both classical and DFSS reliability techniques Whether designing telecom, aerospace, automotive, medical, financial, or public safety systems, every engineer aims for the utmost reliability and availability in the systems he, or she, designs. But between the dream of world-class performance and reality falls the shadow of complexities that can bedevil even the most rigorous design process. While there are an array of robust predictive engineering tools, there has been no single-source guide to understan

  14. Validity and reliability of the TED-QOL: a new three-item questionnaire to assess quality of life in thyroid eye disease.

    Science.gov (United States)

    Fayers, Tessa; Dolman, Peter J

    2011-12-01

    To develop and test a user-friendly questionnaire for rapidly assessing quality of life (QOL) in thyroid eye disease (TED). A three-item questionnaire, the TED-QOL, was designed and compared to the 16-item Graves Ophthalmopathy (GO)-QOL and the nine-item GO-Quality of Life Scale (QLS). 100 patients with TED were administered all three questionnaires on two occasions. Results were compared to clinical severity scores (Vision, Inflammation, Strabismus, Appearance (VISA) classification). Main outcomes were construct and criterion validity, test-retest reliability, duration, comprehension and completion rates. TED-QOL correlated strongly with the other questionnaires for corresponding items (Pearson correlation: appearance 0.71, 0.62; functioning 0.69, 0.66; overall QOL 0.53). Test-retest analysis demonstrated good reliability for all three questionnaires (intraclass correlations: TED-QOL 0.81, 0.74, 0.87; GO-QOL 0.81, 0.82; GO-QLS 0.74, 0.86, 0.67). TED-QOL was significantly faster to complete (1.6 min vs GO-QOL 3.1 min, GO-QLS 2.7 min, p<0.0001) and had a higher completion rate (100% vs GO-QOL 78%, GO-QLS 94%). There was only moderate correlation between items on all three questionnaires and VISA scores. The TED-QOL is rapid and easy to complete and analyse and has similar validity and reliability to longer questionnaires. All questionnaires showed only moderate correlation with disease severity, emphasising the discrepancy between objective and subjective assessments and the importance of measuring both.

  15. Mechanical Integrity Issues at MCM-Cs for High Reliability Applications

    International Nuclear Information System (INIS)

    Morgenstern, H.A.; Tarbutton, T.J.; Becka, G.A.; Uribe, F.; Monroe, S.; Burchett, S.

    1998-01-01

    During the qualification of a new high reliability low-temperature cofired ceramic (LTCC) multichip module (MCM), two issues relating to the electrical and mechanical integrity of the LTCC network were encountered while performing qualification testing. One was electrical opens after aging tests that were caused by cracks in the solder joints. The other was fracturing of the LTCC networks during mechanical testing. Through failure analysis, computer modeling, bend testing, and test samples, changes were identified. Upon implementation of all these changes, the modules passed testing, and the MCM was placed into production

  16. A national drug related problems database: evaluation of use in practice, reliability and reproducibility

    DEFF Research Database (Denmark)

    Kjeldsen, Lene Juel; Birkholm, Trine; Fischer, Hanne Lis

    2014-01-01

    Background A drug related problems database (DRP-database) was developed on request by clinical pharmacists. The information from the DRP-database has only been used locally e.g. to identify focus areas and to communicate identified DRPs to the hospital wards. Hence the quality of the data...... by clinical pharmacists with categorization performed by the project group. Reproducibility was explored by re-categorization of a sample of existing records in the DRP-database by two project group members individually. Main outcome measures Observed proportion of agreement and Fleiss' kappa as measures...... reliability study of 34 clinical pharmacists showed high inter-rater reliability with the project group (Fleiss' kappa = 0.79 with 95 % CI (0.70; 0.88)), and the reproducibility study also documented high inter-rater reliability of a sample of 379 records from the DRP-database re-categorized by two project...

  17. Highly reliable field electron emitters produced from reproducible damage-free carbon nanotube composite pastes with optimal inorganic fillers

    Science.gov (United States)

    Kim, Jae-Woo; Jeong, Jin-Woo; Kang, Jun-Tae; Choi, Sungyoul; Ahn, Seungjoon; Song, Yoon-Ho

    2014-02-01

    Highly reliable field electron emitters were developed using a formulation for reproducible damage-free carbon nanotube (CNT) composite pastes with optimal inorganic fillers and a ball-milling method. We carefully controlled the ball-milling sequence and time to avoid any damage to the CNTs, which incorporated fillers that were fully dispersed as paste constituents. The field electron emitters fabricated by printing the CNT pastes were found to exhibit almost perfect adhesion of the CNT emitters to the cathode, along with good uniformity and reproducibility. A high field enhancement factor of around 10 000 was achieved from the CNT field emitters developed. By selecting nano-sized metal alloys and oxides and using the same formulation sequence, we also developed reliable field emitters that could survive high-temperature post processing. These field emitters had high durability to post vacuum annealing at 950 °C, guaranteeing survival of the brazing process used in the sealing of field emission x-ray tubes. We evaluated the field emitters in a triode configuration in the harsh environment of a tiny vacuum-sealed vessel and observed very reliable operation for 30 h at a high current density of 350 mA cm-2. The CNT pastes and related field emitters that were developed could be usefully applied in reliable field emission devices.

  18. TOTAL QUALITY MANAGEMENT IN HIGH EDUCATION

    Directory of Open Access Journals (Sweden)

    Hasan SERİN, Alper AYTEKİN

    2009-01-01

    Full Text Available The approach of Total Quality Management (TQM has been even more common and most recently its use in high education has been discussed. Likewise the enterprises producing various products, universities have also inputs, processes, and outputs. Due to conditions of competition, universities have to improve the qualities of these inputs, processes, and outputs, according to satisfaction, demands, and expectations of internal and external customers. If the TQM has been implemented in the universities with a manner that aims for customer satisfaction (students, lecturers, public and private establishments, and families, supports constant development, ensures participatory approach, and encourages working in groups, it will provide universities with effectiveness, efficiency, dynamics, and economics. In this study, common problems of universities, definitions of quality and TQM in high education, customer concept at universities, and factors affecting the quality of education have been explained. Besides, in order TQM approach to be successfully implemented in the universities, various suggestions have been presented.

  19. HitPredict version 4: comprehensive reliability scoring of physical protein?protein interactions from more than 100 species

    OpenAIRE

    L?pez, Yosvany; Nakai, Kenta; Patil, Ashwini

    2015-01-01

    HitPredict is a consolidated resource of experimentally identified, physical protein?protein interactions with confidence scores to indicate their reliability. The study of genes and their inter-relationships using methods such as network and pathway analysis requires high quality protein?protein interaction information. Extracting reliable interactions from most of the existing databases is challenging because they either contain only a subset of the available interactions, or a mixture of p...

  20. Analysis of the reliability of quality assurance of welded nuclear pressure vessels with regard to catastrophic failure

    Energy Technology Data Exchange (ETDEWEB)

    Ostberg, G [Lund Institute of Technology, Dept. of Materials Engineering (Sweden); Klingenstierna, B [FTL, Military Electronics Laboratory, National Defence Research Institute, Stockholm (Sweden); Sjoberg, L [Goteborg Univ., Dept. of Psychology (Sweden)

    1976-07-01

    The project is described as an analysis of the reliability of quality assurance of welded nuclear pressure vessels with regard to catastrophic failure. Its scope extends both beyond previous statistical evaluations of the risk of catastrophic failure, beyond previous studies of human malfunction, and beyond current studies of probabilistic fracture mechanics. The latter deal only with 'normal' data and 'normal' processes and procedures according to established rules and regulations, where as the present study concerns deficiencies or more or less complete fallacies of normal procedures and processes. Hopefully such events will prove to be rare enough to be characterized as 'unique'; this, in turn, means that the result of the investigation is not a new statistical figure but rather a survey of types and frequencies of errors and error-producing conditions. The emphasis is on the main pressure vessel; related information on the primary circuit is included, only when this can be done without excessive effort or costs. The avenues of approach in terms of technical-academic disciplines are reliability techniques and the psychology of analysis work and control processes.

  1. Analysis of high-quality modes in open chaotic microcavities

    International Nuclear Information System (INIS)

    Fang, W.; Yamilov, A.; Cao, H.

    2005-01-01

    We present a numerical study of the high-quality modes in two-dimensional dielectric stadium microcavities. Although the classical ray mechanics is fully chaotic in a stadium billiard, all of the high-quality modes show a 'strong scar' around unstable periodic orbits. When the deformation (ratio of the length of the straight segments over the diameter of the half circles) is small, the high-quality modes correspond to whispering-gallery-type trajectories and their quality factors decrease monotonically with increasing deformation. At large deformation, each high-quality mode is associated with multiple unstable periodic orbits. Its quality factor changes nonmonotonically with the deformation, and there exists an optimal deformation for each mode at which its quality factor reaches a local maximum. This unusual behavior is attributed to the interference of waves propagating along different constituent orbits that could minimize light leakage out of the cavity

  2. Measuring Passenger Travel Time Reliability Using Smart Card Data

    NARCIS (Netherlands)

    Bagherian, M.; Cats, O.; van Oort, N.; Hickman, M

    2016-01-01

    Service reliability is a key performance measure for transit agencies in increasing their service quality and thus ridership. Conventional reliability metrics are established based on vehicle movements and thus do not adequately reflect passenger’s experience. In the past few years, the growing

  3. Applying the High Reliability Health Care Maturity Model to Assess Hospital Performance: A VA Case Study.

    Science.gov (United States)

    Sullivan, Jennifer L; Rivard, Peter E; Shin, Marlena H; Rosen, Amy K

    2016-09-01

    The lack of a tool for categorizing and differentiating hospitals according to their high reliability organization (HRO)-related characteristics has hindered progress toward implementing and sustaining evidence-based HRO practices. Hospitals would benefit both from an understanding of the organizational characteristics that support HRO practices and from knowledge about the steps necessary to achieve HRO status to reduce the risk of harm and improve outcomes. The High Reliability Health Care Maturity (HRHCM) model, a model for health care organizations' achievement of high reliability with zero patient harm, incorporates three major domains critical for promoting HROs-Leadership, Safety Culture, and Robust Process Improvement ®. A study was conducted to examine the content validity of the HRHCM model and evaluate whether it can differentiate hospitals' maturity levels for each of the model's components. Staff perceptions of patient safety at six US Department of Veterans Affairs (VA) hospitals were examined to determine whether all 14 HRHCM components were present and to characterize each hospital's level of organizational maturity. Twelve of the 14 components from the HRHCM model were detected; two additional characteristics emerged that are present in the HRO literature but not represented in the model-teamwork culture and system-focused tools for learning and improvement. Each hospital's level of organizational maturity could be characterized for 9 of the 14 components. The findings suggest the HRHCM model has good content validity and that there is differentiation between hospitals on model components. Additional research is needed to understand how these components can be used to build the infrastructure necessary for reaching high reliability.

  4. The interplay between academic performance and quality of life among preclinical students.

    Science.gov (United States)

    Shareef, Mohammad Abrar; AlAmodi, Abdulhadi A; Al-Khateeb, Abdulrahman A; Abudan, Zainab; Alkhani, Mohammed A; Zebian, Sanderlla I; Qannita, Ahmed S; Tabrizi, Mariam J

    2015-10-31

    The high academic performance of medical students greatly influences their professional competence in long term career. Meanwhile, medical students greatly demand procuring a good quality of life that can help them sustain their medical career. This study examines validity and reliability of the tool among preclinical students and testifies the influence of their scholastic performance along with gender and academic year on their quality of life. A cross sectional study was conducted by distributing World Health Organization Quality of Life, WHOQOL-BREF, survey among medical students of year one to three at Alfaisal University. For validity, item discriminate validity(IDV) and confirmatory factor analysis were measured and for reliability, Cronbach's α test and internal item consistency(IIC) were examined. The association of GPA, gender and academic year with all major domains was drawn using Pearson's correlation, independent samples t-test and one-way ANOVA, respectively. A total of 335 preclinical students have responded to this questionnaire. The construct has demonstrated an adequate validity and good reliability. The high academic performance of students positively correlated with physical (r = 0.23, p student scored higher than female peers in physical and psychological health. This study has identified a direct relationship between the academic performance of preclinical students and their quality of life. The WHOQOL-BREF is a valid and reliable tool among preclinical students and the positive direction of high academic performance with greater QOL suggests that academic achievers procure higher satisfaction and poor achievers need a special attention for the improvement of their quality of life.

  5. Measurement system with high accuracy for laser beam quality.

    Science.gov (United States)

    Ke, Yi; Zeng, Ciling; Xie, Peiyuan; Jiang, Qingshan; Liang, Ke; Yang, Zhenyu; Zhao, Ming

    2015-05-20

    Presently, most of the laser beam quality measurement system collimates the optical path manually with low efficiency and low repeatability. To solve these problems, this paper proposed a new collimated method to improve the reliability and accuracy of the measurement results. The system accuracy controlled the position of the mirror to change laser beam propagation direction, which can realize the beam perpendicularly incident to the photosurface of camera. The experiment results show that the proposed system has good repeatability and the measuring deviation of M2 factor is less than 0.6%.

  6. Trends of HVDC technology - highly reliable converting equipment

    International Nuclear Information System (INIS)

    Muraoka, Yasuo; Kato, Yasushi; Watanabe, Atsumi; Kano, Takashi; Kawai, Tadao

    1983-01-01

    At present, the DC power transmission in Japan is practically used for the system connection of relatively small capacity, and the reliability of AC-DC converting system has been proven to exceed the world level by the operational results. However, when the application of this system to trunk power transmission of large capacity in future is considered, it is desirable to raise the reliability of converting equipment further and to develop the stabilized control techniques in harmony with connected AC system. Hitachi Ltd. has developed diversified system-related technologies centering around DC power transmission and the techniques for raising the reliability of converting equipment tending to large capacity. In this report, the results and the future prospect are described. The recent trend of DC power transmission, the development of DC power transmission technology such as the simulation analysis, the stable operation of a DC system connected to a weak AC system and the DC independent transmission from nuclear power stations, the technical development of light direct ignition thyristor bulbs and control protection equipment are reported. (Kako, I.)

  7. Quality of nursing intensity data: inter-rater reliability of the patient classification after two decades in clinical use.

    Science.gov (United States)

    Liljamo, Pia; Kinnunen, Ulla-Mari; Ohtonen, Pasi; Saranto, Kaija

    2017-09-01

    The aim of this study was to measure the inter-rater reliability of the Oulu Patient Classification and to discuss existing methods of reliability testing. The Oulu Patient Classification, part of the RAFAELA ® System, has been developed to assist nursing managers with the proper allocation of nursing resources. Due to the increased intensity of inpatient care during recent years, there is a need for the reliability testing of the classification, which has been in clinical use for 20 years. Retrospective statistical study. To test inter-rater reliability, a pair of nurses classified the same patients, without knowledge of each other's ratings, as a part of annually conducted standardization. Data on the parallel classifications (n = 19,997) was obtained from inpatient units (n = 32) with different specialties at a university hospital in Finland during 2010-2015. Parallel classification practices were also analysed. The reliability of the overall classification and its subareas were calculated using suitable statistical coefficients. Inter-rater reliability coefficients were a reliable or almost perfect means of considering the nursing intensity category and various practices, but there were detectable differences between subareas. The lowest agreement levels occurred in the subareas 'Planning and Coordination of Nursing Care' and 'Guiding of Care/Continued Care and Emotional Support'. There is a need to develop the descriptions of subareas and to clarify the related concepts. Precise nursing documentation can promote a high level of agreement and reliable results. The traditional overall proportion of agreement does not provide an adequate picture of reliability - weighted kappa coefficients should be used instead. © 2017 John Wiley & Sons Ltd.

  8. Reliability and maintainability assessment factors for reliable fault-tolerant systems

    Science.gov (United States)

    Bavuso, S. J.

    1984-01-01

    A long term goal of the NASA Langley Research Center is the development of a reliability assessment methodology of sufficient power to enable the credible comparison of the stochastic attributes of one ultrareliable system design against others. This methodology, developed over a 10 year period, is a combined analytic and simulative technique. An analytic component is the Computer Aided Reliability Estimation capability, third generation, or simply CARE III. A simulative component is the Gate Logic Software Simulator capability, or GLOSS. The numerous factors that potentially have a degrading effect on system reliability and the ways in which these factors that are peculiar to highly reliable fault tolerant systems are accounted for in credible reliability assessments. Also presented are the modeling difficulties that result from their inclusion and the ways in which CARE III and GLOSS mitigate the intractability of the heretofore unworkable mathematics.

  9. Translation, data quality, reliability, validity and responsiveness of the Norwegian version of the Effective Musculoskeletal Consumer Scale (EC-17

    Directory of Open Access Journals (Sweden)

    Kristjansson Elizabeth

    2010-01-01

    Full Text Available Abstract Background The Effective Musculoskeletal Consumer Scale (EC-17 is a self-administered questionnaire for evaluating self-management interventions that empower and educate people with rheumatic conditions. The aim of the study was to translate and evaluate the Norwegian version of EC-17 against the necessary criteria for a patient-reported outcome measure, including responsiveness to change. Methods Data quality, reliability, validity and responsiveness were assessed in two groups. One group comprising 103 patients received a questionnaire before and at the end of a self-management programme. The second group comprising 96 patients' received the questionnaire two weeks before and on arrival of the program. Internal consistency and test-retest reliability were assessed. Construct validity was assessed through comparisons with the Brief Approach/Avoidance Coping Questionnaire, (BACQ, the Emotional Approach Coping Scale (EAC and the General Health Questionnaire (GHQ-20. Responsiveness was assessed with the Standardised Response Mean (SRM. Results Respondents included 66 (64% and 52 (54% patients from the first and second groups respectively. Levels of missing data were low for all items. There was good evidence for unidimensionality, item-total correlations ranged from 0.59 to 0.82 and Cronbach's Alpha and test-retest correlations were over 0.90. As hypothesised EC-17 scores had statistically significant low to moderate correlations with the BACQ, EAC and GHQ-20 in the range 0.26 to 0.42. Following the self-management program, EC-17 scores showed a significant improvement with an SRM of 0.48. Conclusion The Norwegian version of the EC-17 has evidence for data quality, internal consistency and test-retest reliability, construct validity and responsiveness to change. The EC-17 seems promising as an outcome measure for evaluating self-management interventions for people with rheumatic conditions, but further studies are needed.

  10. Translation, data quality, reliability, validity and responsiveness of the Norwegian version of the Effective Musculoskeletal Consumer Scale (EC-17).

    Science.gov (United States)

    Hamnes, Bente; Garratt, Andrew; Kjeken, Ingvild; Kristjansson, Elizabeth; Hagen, Kåre B

    2010-01-29

    The Effective Musculoskeletal Consumer Scale (EC-17) is a self-administered questionnaire for evaluating self-management interventions that empower and educate people with rheumatic conditions. The aim of the study was to translate and evaluate the Norwegian version of EC-17 against the necessary criteria for a patient-reported outcome measure, including responsiveness to change. Data quality, reliability, validity and responsiveness were assessed in two groups. One group comprising 103 patients received a questionnaire before and at the end of a self-management programme. The second group comprising 96 patients' received the questionnaire two weeks before and on arrival of the program. Internal consistency and test-retest reliability were assessed. Construct validity was assessed through comparisons with the Brief Approach/Avoidance Coping Questionnaire, (BACQ), the Emotional Approach Coping Scale (EAC) and the General Health Questionnaire (GHQ-20). Responsiveness was assessed with the Standardised Response Mean (SRM). Respondents included 66 (64%) and 52 (54%) patients from the first and second groups respectively. Levels of missing data were low for all items. There was good evidence for unidimensionality, item-total correlations ranged from 0.59 to 0.82 and Cronbach's Alpha and test-retest correlations were over 0.90. As hypothesised EC-17 scores had statistically significant low to moderate correlations with the BACQ, EAC and GHQ-20 in the range 0.26 to 0.42. Following the self-management program, EC-17 scores showed a significant improvement with an SRM of 0.48. The Norwegian version of the EC-17 has evidence for data quality, internal consistency and test-retest reliability, construct validity and responsiveness to change. The EC-17 seems promising as an outcome measure for evaluating self-management interventions for people with rheumatic conditions, but further studies are needed.

  11. Using wind plant data to increase reliability.

    Energy Technology Data Exchange (ETDEWEB)

    Peters, Valerie A. (Sandia National Laboratories, Livermore, CA); Ogilvie, Alistair B.; McKenney, Bridget L.

    2011-01-01

    Operators interested in improving reliability should begin with a focus on the performance of the wind plant as a whole. To then understand the factors which drive individual turbine performance, which together comprise the plant performance, it is necessary to track a number of key indicators. Analysis of these key indicators can reveal the type, frequency, and cause of failures and will also identify their contributions to overall plant performance. The ideal approach to using data to drive good decisions includes first determining which critical decisions can be based on data. When those required decisions are understood, then the analysis required to inform those decisions can be identified, and finally the data to be collected in support of those analyses can be determined. Once equipped with high-quality data and analysis capabilities, the key steps to data-based decision making for reliability improvements are to isolate possible improvements, select the improvements with largest return on investment (ROI), implement the selected improvements, and finally to track their impact.

  12. Recent progress in high performance and reliable n-type transition metal oxide-based thin film transistors

    International Nuclear Information System (INIS)

    Yeon Kwon, Jang; Kyeong Jeong, Jae

    2015-01-01

    This review gives an overview of the recent progress in vacuum-based n-type transition metal oxide (TMO) thin film transistors (TFTs). Several excellent review papers regarding metal oxide TFTs in terms of fundamental electron structure, device process and reliability have been published. In particular, the required field-effect mobility of TMO TFTs has been increasing rapidly to meet the demands of the ultra-high-resolution, large panel size and three dimensional visual effects as a megatrend of flat panel displays, such as liquid crystal displays, organic light emitting diodes and flexible displays. In this regard, the effects of the TMO composition on the performance of the resulting oxide TFTs has been reviewed, and classified into binary, ternary and quaternary composition systems. In addition, the new strategic approaches including zinc oxynitride materials, double channel structures, and composite structures have been proposed recently, and were not covered in detail in previous review papers. Special attention is given to the advanced device architecture of TMO TFTs, such as back-channel-etch and self-aligned coplanar structure, which is a key technology because of their advantages including low cost fabrication, high driving speed and unwanted visual artifact-free high quality imaging. The integration process and related issues, such as etching, post treatment, low ohmic contact and Cu interconnection, required for realizing these advanced architectures are also discussed. (invited review)

  13. The reliability of structural systems operating at high temperature: Replacing engineering judgement with operational experience

    International Nuclear Information System (INIS)

    Chevalier, M.J.; Smith, D.J.; Dean, D.W.

    2012-01-01

    Deterministic assessments are used to assess the integrity of structural systems operating at high temperature by providing a lower bound lifetime prediction, requiring considerable engineering judgement. However such a result may not satisfy the structural integrity assessment purpose if the results are overly conservative or conversely plant observations (such as failures) could undermine the assessment result if observed before the lower bound lifetime. This paper develops a reliability methodology for high temperature assessments and illustrates the impact and importance of managing the uncertainties within such an analysis. This is done by separating uncertainties into three classifications; aleatory uncertainty, quantifiable epistemic uncertainty and unquantifiable epistemic uncertainty. The result is a reliability model that can predict the behaviour of a structural system based upon plant observations, including failure and survival data. This can be used to reduce the over reliance upon engineering judgement which is prevalent in deterministic assessments. Highlights: ► Deterministic assessments are shown to be heavily reliant upon engineering judgment. ► Based upon the R5 procedure, a reliability model for a structural system is developed. ► Variables must be classified as either aleatory or epistemic to model their impact on reliability. ► Operation experience is then used to reduce reliance upon engineering judgment. ► This results in a model which can predict system behaviour and learn from operational experience.

  14. Reliability and validity of the Wolfram Unified Rating Scale (WURS

    Directory of Open Access Journals (Sweden)

    Nguyen Chau

    2012-11-01

    Full Text Available Abstract Background Wolfram syndrome (WFS is a rare, neurodegenerative disease that typically presents with childhood onset insulin dependent diabetes mellitus, followed by optic atrophy, diabetes insipidus, deafness, and neurological and psychiatric dysfunction. There is no cure for the disease, but recent advances in research have improved understanding of the disease course. Measuring disease severity and progression with reliable and validated tools is a prerequisite for clinical trials of any new intervention for neurodegenerative conditions. To this end, we developed the Wolfram Unified Rating Scale (WURS to measure the severity and individual variability of WFS symptoms. The aim of this study is to develop and test the reliability and validity of the Wolfram Unified Rating Scale (WURS. Methods A rating scale of disease severity in WFS was developed by modifying a standardized assessment for another neurodegenerative condition (Batten disease. WFS experts scored the representativeness of WURS items for the disease. The WURS was administered to 13 individuals with WFS (6-25 years of age. Motor, balance, mood and quality of life were also evaluated with standard instruments. Inter-rater reliability, internal consistency reliability, concurrent, predictive and content validity of the WURS were calculated. Results The WURS had high inter-rater reliability (ICCs>.93, moderate to high internal consistency reliability (Cronbach’s α = 0.78-0.91 and demonstrated good concurrent and predictive validity. There were significant correlations between the WURS Physical Assessment and motor and balance tests (rs>.67, ps>.76, ps=-.86, p=.001. The WURS demonstrated acceptable content validity (Scale-Content Validity Index=0.83. Conclusions These preliminary findings demonstrate that the WURS has acceptable reliability and validity and captures individual differences in disease severity in children and young adults with WFS.

  15. The reliability, validity and responsiveness of the Thai version of Systemic Lupus Erythematosus Quality of Life (SLEQOL-TH) instrument.

    Science.gov (United States)

    Kasitanon, N; Wangkaew, S; Puntana, S; Sukitawut, W; Leong, K P; Louthrenoo, W

    2013-03-01

    The English version of the Systemic Lupus Erythematosus Quality of Life Questionnaire (SLEQOL) is a validated disease-specific quality of life instrument. The aim of this study was to evaluate the psychometric properties of the Thai version of the SLEQOL (SLEQOL-TH). Two independent translators translated the SLEQOL into Thai. The back translation of this version was performed by two other independent translators. The final version, SLEQOL-TH, was completed after resolving the discrepancies revealed by the back translation. One hundred and nine patients with SLE were enrolled to test the reliability, construct validity, floor and ceiling effects, and sensitivity to the changes of the SLEQOL-TH at six months. The differential item functioning (DIF) between the Thai and English versions was analyzed using the partial gamma. The internal consistency of the SLEQOL-TH was satisfactory with the overall Cronbach's alpha of 0.86. The test-retest reliability of the SLEQOL-TH was acceptable with the intra-class correlation coefficient of 0.86. Low correlations between the SLEQOL-TH and SLEDAI were observed. The total score of the SLEQOL-TH was moderately responsive to changes in quality of life, with a standardized response mean of 0.50. When comparing the SLEQOL-TH from Thai SLE patients with the original SLEQOL version obtained from Singapore SLE patients, 11 out of 40 items showed a moderate to large DIF. The SLEQOL-TH has acceptable psychometric properties and shows construct validity. In comparison with the English version of SLEQOL, there are some items that showed DIF. The applicability of the SLEQOL-TH in real-life clinical practice and clinical trials needs to be determined.

  16. System reliability developments in structural engineering

    International Nuclear Information System (INIS)

    Moses, F.

    1982-01-01

    Two major limitations occur in present structural design code developments utilizing reliability theory. The notional system reliabilities may differ significantly from calibrated component reliabilities. Secondly, actual failures are often due to gross errors not reflected in most present code formats. A review is presented of system reliability methods and further new concepts are developed. The incremental load approach for identifying and expressing collapse modes is expanded by employing a strategy to identify and enumerate the significant structural collapse modes. It further isolates the importance of critical components in the system performance. Ductile and brittle component behavior and strength correlation is reflected in the system model and illustrated in several examples. Modal combinations for the system reliability are also reviewed. From these developments a system factor can be addended to component safety checking equations. Values may be derived from system behavior by substituting in a damage model which accounts for the response range from component failure to collapse. Other strategies are discussed which emphasize quality assurance during design and in-service inspection for components whose behavior is critical to the system reliability. (Auth.)

  17. On the Effect of Security and Communication Factors in the Reliability of Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Damian Rusinek

    2014-03-01

    Full Text Available The ensuring reliability of wireless sensor networks (WSN is one of most important problems to be solved. In this article, the influence of the security and communication factors in the reliability of Wireless Sensor Networks was analyzed. Balancing security against performance in WSN is another issue to be solved. These factors should be considered during security analysis of quality of protection of realized protocol. In the article, we analyze wireless sensor network where hierarchical topologies is implemented with high performance routing sensors that forward big amount of data. We present the experiment results which were performed by high-performance Imote2 sensor platform and TinyOS operating system.

  18. The Chinese version of the Pediatric Quality of Life Inventory™ (PedsQL™) 3.0 Asthma Module: reliability and validity.

    Science.gov (United States)

    Feng, Lifen; Zhang, Yingfen; Chen, Ruoqing; Hao, Yuantao

    2011-08-07

    Health-related quality of life (HRQOL) has been recognized as an important health outcome measurement for pediatric patients. One of the most promising instruments in measuring pediatric HRQOL emerged in recent years is the Pediatric Quality of Life Inventory (PedsQL™). The PedsQL™ 3.0 Asthma Module, one of the PedsQL™disease-specific scales, was designed to measure HRQOL dimensions specifically tailored for pediatric asthma. The present study is aimed to evaluate the psychometric properties of the Chinese version of the PedsQL™ 3.0 Asthma Module. The PedsQL™ 3.0 Asthma Module was translated into Chinese following the PedsQL™ Measurement Model Translation Methodology. The Chinese version scale was administered to 204 children with asthma and 337 parents of children with asthma from four Triple A hospitals. The psychometric properties were then evaluated. The percentage of missing value for each item of the scale ranged from 0.00% to 8.31%. All child self-report subscales and parent proxy-report subscales approached or exceeded the minimum reliability standard of 0.70 for alpha coefficient, except 3 subscales of Young Child (aged 5-7) self-report (alphas ranging from 0.59 to 0.68). Test-retest reliability was satisfactory with intraclass correlation coefficients (ICCs) which exceeded the recommended standard of 0.80 in all subscales. Correlation coefficients between items and their hypothesized subscales were higher than those with other subscales. The PedsQL™ 3.0 Asthma Module distinguished between outpatients and inpatients. Patients with mild asthma reported higher scores than those with moderate/severe asthma in majority of subscales. The intercorrelations among the PedsQL™ 3.0 Asthma Module subscales and the PedsQL™ 4.0 Generic Core Scales were in medium to large effect size. The child self-report scores were consistent with the parent proxy-report scores. The Chinese version of the PedsQL™ 3.0 Asthma Module has acceptable psychometric

  19. Implementasi Wireless Quality of Service dengan Metode Load Switching Jaringan Seluler Menggunakan Software Defined Network untuk Meningkatkan Network Reliability pada Jaringan Dinamis

    Directory of Open Access Journals (Sweden)

    Yoga Bayu Aji Pranawa

    2017-03-01

    Full Text Available Wireless Quality of Service (QOS adalah salah satu dimensi mobilitas, yaitu sebuah metode yang digunakan untuk menjaga kualitas suatu jaringan nirkabel. QOS diperlukan sebagai sebuah metode untuk memenuhi kriteria pelayanan sistem bagi pengguna, yaitu confidentiality, integrity, dan availability. Beberapa aspek yang menjadi topik utama dalam QOS adalah failure and recovery mechanism, variable bandwidth, computing distribution, discovery mechanism, variable lantency, dan performance feedback. Wireless yang dibahas pada penelitian ini dititik beratkan pada jaringan seluler yang cenderung tidak reliable pada daerah tertentu. Oleh karena itu dibutuhkan sebuah mekanisme yang dapat mengatasi tidak stabilnya jaringan seluler tersebut. mplementasi mekanisme yang diterapkan pada penelitian ini adalah dengan menerapkan load switching pada jaringan seluler dengan menggunakan beberapa provider dan menerapkan teknologi Software Defined Network (SDN. Berdasarkan hasi uji coba dapat disimpulkan bahwa sistem yang dibuat pada penelitian ini dapat menerapkan wireless quality of service dan meningkatkan network reliability sebesar 65,29% dan 83,87% lebih baik untuk penggunaan tanpa waktu tunggu dan dengan waktu tunggu pada suatu jaringan  dinamis.

  20. High beam quality and high energy short-pulse laser with MOPA

    Science.gov (United States)

    Jin, Quanwei; Pang, Yu; Jiang, JianFeng; Tan, Liang; Cui, Lingling; Wei, Bin; Sun, Yinhong; Tang, Chun

    2018-03-01

    A high energy, high beam quality short-pulse diode-pumped Nd:YAG master oscillator power-amplifier (MOPA) laser with two amplifier stages is demonstrated. The two-rod birefringence compensation was used as beam quality controlling methods, which presents a short-pulse energy of 40 mJ with a beam quality value of M2 = 1.2 at a repetition rate of 400Hz. The MOPA system delivers a short-pulse energy of 712.5 mJ with a pulse width of 12.4 ns.The method of spherical aberration compensation is improved the beam quality, a M2 factor of 2.3 and an optical-to-optical efficiency of 27.7% is obtained at the maximum laser out power.The laser obtained 1.4J out energy with polarization integration.

  1. High reliability - low noise radionuclide signature identification algorithms for border security applications

    Science.gov (United States)

    Lee, Sangkyu

    Illicit trafficking and smuggling of radioactive materials and special nuclear materials (SNM) are considered as one of the most important recent global nuclear threats. Monitoring the transport and safety of radioisotopes and SNM are challenging due to their weak signals and easy shielding. Great efforts worldwide are focused at developing and improving the detection technologies and algorithms, for accurate and reliable detection of radioisotopes of interest in thus better securing the borders against nuclear threats. In general, radiation portal monitors enable detection of gamma and neutron emitting radioisotopes. Passive or active interrogation techniques, present and/or under the development, are all aimed at increasing accuracy, reliability, and in shortening the time of interrogation as well as the cost of the equipment. Equally important efforts are aimed at advancing algorithms to process the imaging data in an efficient manner providing reliable "readings" of the interiors of the examined volumes of various sizes, ranging from cargos to suitcases. The main objective of this thesis is to develop two synergistic algorithms with the goal to provide highly reliable - low noise identification of radioisotope signatures. These algorithms combine analysis of passive radioactive detection technique with active interrogation imaging techniques such as gamma radiography or muon tomography. One algorithm consists of gamma spectroscopy and cosmic muon tomography, and the other algorithm is based on gamma spectroscopy and gamma radiography. The purpose of fusing two detection methodologies per algorithm is to find both heavy-Z radioisotopes and shielding materials, since radionuclides can be identified with gamma spectroscopy, and shielding materials can be detected using muon tomography or gamma radiography. These combined algorithms are created and analyzed based on numerically generated images of various cargo sizes and materials. In summary, the three detection

  2. High quality-factor optical resonators

    International Nuclear Information System (INIS)

    Henriet, Rémi; Salzenstein, Patrice; Coillet, Aurélien; Saleh, Khaldoun; Chembo, Yanne K; Ristic, Davor; Ferrari, Maurizio; Mortier, Michel; Rasoloniaina, Alphonse; Dumeige, Yannick; Féron, Patrice; Cibiel, Gilles; Llopis, Olivier

    2014-01-01

    Various resonators are investigated for microwave photonic applications. Micro-sphere, disk and fiber ring resonators were designed, realized and characterized. Obtained quality factors are as high as Q = 10 10 . (paper)

  3. Retail banking service quality: A client perception study

    Directory of Open Access Journals (Sweden)

    Mbablemhle Bhengu

    2016-11-01

    Full Text Available The retail banking sector in South Africa is predominantly characterised by a high face to face interaction and constant product and pricing differentiation. In order for a bank to distinguish itself from other banks in the banking industry, it uses excellence in its service quality to stand out against its competitors. In the study, the researchers adapted the SERVQUAL model to the banking industry. A probability sampling technique was employed for the study. Simple random sampling was employed to test MBA students’ perceptions towards service quality in the banking industry. The findings in the empirical study revealed that MBA students at the university were dissatisfied with the quality of service offerings provided by the retail banks in South Africa. There were quality gaps revealed in tangibles, reliability, empathy, responsiveness and reliability aspects of the service encounters

  4. Reliability of spring interconnects for high channel-count polyimide electrode arrays

    Science.gov (United States)

    Khan, Sharif; Ordonez, Juan Sebastian; Stieglitz, Thomas

    2018-05-01

    Active neural implants with a high channel-count need robust and reliable operational assembly for the targeted environment in order to be classified as viable fully implantable systems. The discrete functionality of the electrode array and the implant electronics is vital for intact assembly. A critical interface exists at the interconnection sites between the electrode array and the implant electronics, especially in hybrid assemblies (e.g. retinal implants) where electrodes and electronics are not on the same substrate. Since the interconnects in such assemblies cannot be hermetically sealed, reliable protection against the physiological environment is essential for delivering high insulation resistance and low defusibility of salt ions, which are limited in complexity by current assembly techniques. This work reports on a combination of spring-type interconnects on a polyimide array with silicone rubber gasket insulation for chronically active implantable systems. The spring design of the interconnects on the backend of the electrode array compensates for the uniform thickness of the sandwiched gasket during bonding in assembly and relieves the propagation of extrinsic stresses to the bulk polyimide substrate. The contact resistance of the microflex-bonded spring interconnects with the underlying metallized ceramic test vehicles and insulation through the gasket between adjacent contacts was investigated against the MIL883 standard. The contact and insulation resistances remained stable in the exhausting environmental conditions.

  5. Scheduling for energy and reliability management on multiprocessor real-time systems

    Science.gov (United States)

    Qi, Xuan

    Scheduling algorithms for multiprocessor real-time systems have been studied for years with many well-recognized algorithms proposed. However, it is still an evolving research area and many problems remain open due to their intrinsic complexities. With the emergence of multicore processors, it is necessary to re-investigate the scheduling problems and design/develop efficient algorithms for better system utilization, low scheduling overhead, high energy efficiency, and better system reliability. Focusing cluster schedulings with optimal global schedulers, we study the utilization bound and scheduling overhead for a class of cluster-optimal schedulers. Then, taking energy/power consumption into consideration, we developed energy-efficient scheduling algorithms for real-time systems, especially for the proliferating embedded systems with limited energy budget. As the commonly deployed energy-saving technique (e.g. dynamic voltage frequency scaling (DVFS)) will significantly affect system reliability, we study schedulers that have intelligent mechanisms to recuperate system reliability to satisfy the quality assurance requirements. Extensive simulation is conducted to evaluate the performance of the proposed algorithms on reduction of scheduling overhead, energy saving, and reliability improvement. The simulation results show that the proposed reliability-aware power management schemes could preserve the system reliability while still achieving substantial energy saving.

  6. Improved linearity and reliability in GaN metal-oxide-semiconductor high-electron-mobility transistors using nanolaminate La2O3/SiO2 gate dielectric

    Science.gov (United States)

    Hsu, Ching-Hsiang; Shih, Wang-Cheng; Lin, Yueh-Chin; Hsu, Heng-Tung; Hsu, Hisang-Hua; Huang, Yu-Xiang; Lin, Tai-Wei; Wu, Chia-Hsun; Wu, Wen-Hao; Maa, Jer-Shen; Iwai, Hiroshi; Kakushima, Kuniyuki; Chang, Edward Yi

    2016-04-01

    Improved device performance to enable high-linearity power applications has been discussed in this study. We have compared the La2O3/SiO2 AlGaN/GaN metal-oxide-semiconductor high-electron-mobility transistors (MOS-HEMTs) with other La2O3-based (La2O3/HfO2, La2O3/CeO2 and single La2O3) MOS-HEMTs. It was found that forming lanthanum silicate films can not only improve the dielectric quality but also can improve the device characteristics. The improved gate insulation, reliability, and linearity of the 8 nm La2O3/SiO2 MOS-HEMT were demonstrated.

  7. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG Monitoring

    Directory of Open Access Journals (Sweden)

    Amale Ankhili

    2018-02-01

    Full Text Available A medical quality electrocardiogram (ECG signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene:poly(styrenesulfonate (PEDOT:PSS in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras, by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.

  8. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring.

    Science.gov (United States)

    Ankhili, Amale; Tao, Xuyuan; Cochrane, Cédric; Coulon, David; Koncar, Vladan

    2018-02-07

    A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras), by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.

  9. Reliability of the imaging software in the preoperative planning of the open-wedge high tibial osteotomy.

    Science.gov (United States)

    Lee, Yong Seuk; Kim, Min Kyu; Byun, Hae Won; Kim, Sang Bum; Kim, Jin Goo

    2015-03-01

    The purpose of this study was to verify a recently developed picture-archiving and communications system-photoshop method by comparing reliabilities between real-size paper template and the PACS-photoshop methods in preoperative planning of open-wedge high tibial osteotomy. A prospective case series was conducted, including patients with medial osteoarthritis undergoing open-wedge high tibial osteotomy. In the preoperative planning, the picture-archiving and communications system-photoshop method and real-size paper template method were used simultaneously in all patients. Preoperative hip-knee-ankle angle, height, and angle of the osteotomy were evaluated. The reliability of this newly devised method was evaluated, and the consistency between the two methods was also evaluated using intra-class correlation coefficient. Using the picture-archiving and communications system-photoshop method, the mean correction angle and height of osteotomy gap of rater-1 were 11.7° ± 3.6° and 10.7 ± 3.6 mm, respectively. The mean correction angle and height of osteotomy gap of rater-2 were 12.0 ± 2.6 and 10.8 ± 3.6, respectively. The inter- and intra-rater reliabilities of the correction angle were 0.956 ~ 0.979 and 0.980 ~ 0.992, respectively. The inter- and intra-rater reliabilities of the height of the osteotomy gap were 0.968 ~ 0.985 and 0.971 ~ 0.994, respectively (p photoshop method, mean values of the correction angle and height of the osteotomy gap were 11.9° ± 3.6° and 10.8 ± 3.6 mm, respectively. Consistency between the two methods by comparing the means of the correction angle and the height of the osteotomy gap were 0.985 and 0.985, respectively (p photoshop method enables direct measurement of the height of the osteotomy gap with high reliability.

  10. High-quality cardiopulmonary resuscitation: current and future directions.

    Science.gov (United States)

    Abella, Benjamin S

    2016-06-01

    Cardiopulmonary resuscitation (CPR) represents the cornerstone of cardiac arrest resuscitation care. Prompt delivery of high-quality CPR can dramatically improve survival outcomes; however, the definitions of optimal CPR have evolved over several decades. The present review will discuss the metrics of CPR delivery, and the evidence supporting the importance of CPR quality to improve clinical outcomes. The introduction of new technologies to quantify metrics of CPR delivery has yielded important insights into CPR quality. Investigations using CPR recording devices have allowed the assessment of specific CPR performance parameters and their relative importance regarding return of spontaneous circulation and survival to hospital discharge. Additional work has suggested new opportunities to measure physiologic markers during CPR and potentially tailor CPR delivery to patient requirements. Through recent laboratory and clinical investigations, a more evidence-based definition of high-quality CPR continues to emerge. Exciting opportunities now exist to study quantitative metrics of CPR and potentially guide resuscitation care in a goal-directed fashion. Concepts of high-quality CPR have also informed new approaches to training and quality improvement efforts for cardiac arrest care.

  11. Quality management manual for production of high quality cassava flour

    DEFF Research Database (Denmark)

    Dziedzoave, Nanam Tay; Abass, Adebayo Busura; Amoa-Awua, Wisdom K.

    The high quality cassava flour (HQCF) industry has just started to evolve in Africa and elsewhere. The sustainability of the growing industry, the profitability of small- and medium-scale enterprises (SMEs) that are active in the industry and good-health of consumers can best be guaranteed through...... the adoption of proper quality and food safety procedures. Cassava processing enterprises involved in the productionof HQCF must therefore be commited to the quality and food safety of the HQCF. They must have the right technology, appropriate processing machhinery, standard testing instruments...... and the necessary technical expertise. This quality manual was therefore developed to guide small- to medium-scale cassava in the design and implematation of Hazard Analysis Critical Control Point (HACCP) system and Good manufacturing Practices (GMP) plans for HQCF production. It describes the HQCF production...

  12. PV Systems Reliability Final Technical Report.

    Energy Technology Data Exchange (ETDEWEB)

    Lavrova, Olga [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Flicker, Jack David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Johnson, Jay [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Armijo, Kenneth Miguel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gonzalez, Sigifredo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schindelholz, Eric John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sorensen, Neil R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Yang, Benjamin Bing-Yeh [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    The continued exponential growth of photovoltaic technologies paves a path to a solar-powered world, but requires continued progress toward low-cost, high-reliability, high-performance photovoltaic (PV) systems. High reliability is an essential element in achieving low-cost solar electricity by reducing operation and maintenance (O&M) costs and extending system lifetime and availability, but these attributes are difficult to verify at the time of installation. Utilities, financiers, homeowners, and planners are demanding this information in order to evaluate their financial risk as a prerequisite to large investments. Reliability research and development (R&D) is needed to build market confidence by improving product reliability and by improving predictions of system availability, O&M cost, and lifetime. This project is focused on understanding, predicting, and improving the reliability of PV systems. The two areas being pursued include PV arc-fault and ground fault issues, and inverter reliability.

  13. Technical and human considerations in establishing quality of supply objectives

    International Nuclear Information System (INIS)

    Fraser, J.C.

    1989-01-01

    The standard adopted for the quality of electrical supply ultimately determines the cost of the supply. Technical considerations prevent the achievement of perfect quality at any cost and high quality is gained usually only at high cost. Customer opinion ultimately determines acceptable quality and cost. However, gaining opinion data which is useful for system design is a task that must account for certain human characteristics which influence the reliability of data obtained from surveys. An overview is given of technical factors which limit the quality of supply and human nature impacts on opinion data. Power generation, generation design criteria, transmission system design criteria and subtransmission and distribution criteria for reliability of supply are discussed. Public opinion of electrical power quality is distorted by several influences. While electricity use is continuous, bills come periodically, and the time discrepancy is likely to inflate the perception of energy cost. Periods with low quality problems become expected as the norm, although to a certain degree memory of poor performance is more persistant than memory of good performance, moderating the effect. Costs customers are willing to bear to provide for improved performance are analyzed. 10 refs., 8 figs., 3 tabs

  14. Validity evidence and reliability of a simulated patient feedback instrument.

    Science.gov (United States)

    Schlegel, Claudia; Woermann, Ulrich; Rethans, Jan-Joost; van der Vleuten, Cees

    2012-01-27

    In the training of healthcare professionals, one of the advantages of communication training with simulated patients (SPs) is the SP's ability to provide direct feedback to students after a simulated clinical encounter. The quality of SP feedback must be monitored, especially because it is well known that feedback can have a profound effect on student performance. Due to the current lack of valid and reliable instruments to assess the quality of SP feedback, our study examined the validity and reliability of one potential instrument, the 'modified Quality of Simulated Patient Feedback Form' (mQSF). Content validity of the mQSF was assessed by inviting experts in the area of simulated clinical encounters to rate the importance of the mQSF items. Moreover, generalizability theory was used to examine the reliability of the mQSF. Our data came from videotapes of clinical encounters between six simulated patients and six students and the ensuing feedback from the SPs to the students. Ten faculty members judged the SP feedback according to the items on the mQSF. Three weeks later, this procedure was repeated with the same faculty members and recordings. All but two items of the mQSF received importance ratings of > 2.5 on a four-point rating scale. A generalizability coefficient of 0.77 was established with two judges observing one encounter. The findings for content validity and reliability with two judges suggest that the mQSF is a valid and reliable instrument to assess the quality of feedback provided by simulated patients.

  15. Development of nuclear safety class filter elements with long life and high quality

    International Nuclear Information System (INIS)

    Zhang Jinghua

    2009-04-01

    This paper describes the development on nuclear safety class filter elements with long life and high quality used for collecting radioactive contaminants, fragments of resin and impurities in primary systems of NPPs. The filter elements made of glass fibre elements are used for PWR, and of paper elements are used for PHWR. During the research, a series of tests for optimization were performed for selection of filter material and the improvement of binder. The flow rate and comprehensive performance have been measured in simulated conditions. The result shows that the application requirements for operational NPPs can be met, and the reliability and safety of the frame are also be verified. The comprehensive performance of the filter elements is equivalent to that of oversea similar products. The products have been used in NPPs in operation. (authors)

  16. THE LEAN SIX SIGMAAPPROACH FOR PROCESS IMPROVEMENT: A CASE STUDY IN A HIGH QUALITY TUSCANY WINERY

    Directory of Open Access Journals (Sweden)

    Riccardo Bettini

    2012-06-01

    Full Text Available This paper describes the application of a Lean Six Sigma (LSS project to a winemaking process in a high-quality, Italian winery. LSS is used to focus on the problem through a quantitative analysis of waste and quality performances. The LSS basic algorithm (called “DMAIC” helps to detect and quantify critical aspects of the process for transferring liquid used in the cellar. The improvement solution is developed and applied through the modification of the cellar system and the process procedure. The results obtained with this solution are shown and discussed in this paper, so too the long term reliability of the improved process analyzed. The results obtained by this case study can help to understand the importance of the LSS method to drive the improvement of agricultural and agrofood productions also in terms of environmental impact which is strongly connected to waste reduction.

  17. Improvement of the reliability and efficiency of the NPP operation by training high-skilled personnel

    International Nuclear Information System (INIS)

    Korolev, V.V.; Sereda, G.A.

    1981-01-01

    Nuclear power at the modern stage of development is characterized by utilization of large power commercial reactors high technical specifications and economic parameters of which can be provided only at high reliability of the equipment and high qualification of the personnel. Special educational institution - Institute of nuclear engineering is organized for education of the operation personnel of high qualification for modern NPPs. Discussed are some problems occurring in this connection [ru

  18. Exploitation examination of reliability of coal dust systems

    International Nuclear Information System (INIS)

    Dojchinovski, Ilija; Trajkovski, Kole

    1997-01-01

    Designers and operators wish is, long, failure free operation at designed parameters of every system. Always we know the system start up time, but we don't know how long this system will operate successfully. Because of that in this article is given a method how, step by step, to determine the reliability of the system. Reliability parameters are obtained from experimental and operational data. When reliability parameters are determined then it is very easy to compare reliability of similar systems, for example excavators, or different systems, such as truck and rubber band transport system. Practical use of the theory of reliability is by purchasing of the systems when manufacturers have to have and present reliability parameters and on this way we can decide which system satisfies our needs regarding the quality-price-reliability. Reliability can be practically used in system operation where: 1) system reliability is maintained with proper start, use and shutdown of the system; 2) a system reliability is maintained with good maintenance organization; 3) a system reliability is maintained with innovations and improvements with final purpose removing of the imperfections experienced through the operation. Reliability is very important parameter in power generation plants. (Author)

  19. Reliable processing of graphene using metal etchmasks

    Directory of Open Access Journals (Sweden)

    Peltekis Nikos

    2011-01-01

    Full Text Available Abstract Graphene exhibits exciting properties which make it an appealing candidate for use in electronic devices. Reliable processes for device fabrication are crucial prerequisites for this. We developed a large area of CVD synthesis and transfer of graphene films. With patterning of these graphene layers using standard photoresist masks, we are able to produce arrays of gated graphene devices with four point contacts. The etching and lift off process poses problems because of delamination and contamination due to polymer residues when using standard resists. We introduce a metal etch mask which minimises these problems. The high quality of graphene is shown by Raman and XPS spectroscopy as well as electrical measurements. The process is of high value for applications, as it improves the processability of graphene using high-throughput lithography and etching techniques.

  20. Quality function deployment in launch operations

    Science.gov (United States)

    Portanova, P. L.; Tomei, E. J., Jr.

    1990-11-01

    The goal of the Advanced Launch System (ALS) is a more efficient launch capability that provides a highly reliable and operable system at substantially lower cost than current launch systems. Total Quality Management (TQM) principles are being emphasized throughout the ALS program. A continuous improvement philosophy is directed toward satisfying users' and customer's requirements in terms of quality, performance, schedule, and cost. Quality Function Deployment (QFD) is interpreted as the voice of the customer (or user), and it is an important planning tool in translating these requirements throughout the whole process of design, development, manufacture, and operations. This report explores the application of QFD methodology to launch operations, including the modification and addition of events (operations planning) in the engineering development cycle, and presents an informal status of study results to date. QFD is a technique for systematically analyzing the customer's (Space Command) perceptions of what constitutes a highly reliable and operable system and functionally breaking down those attributes to identify the critical characteristics that determine an efficient launch system capability. In applying the principle of QFD, a series of matrices or charts are developed with emphasis on the one commonly known as the House of Quality (because of its roof-like format), which identifies and translates the most critical information.

  1. Reliability studies of diagnostic methods in Indian traditional Ayurveda medicine

    DEFF Research Database (Denmark)

    Kurande, Vrinda Hitendra; Waagepetersen, Rasmus; Toft, Egon

    2013-01-01

    as prakriti classification), method development (pulse diagnosis), quality assurance for diagnosis and treatment and in the conduct of clinical studies. Several reliability studies are conducted in western medicine. The investigation of the reliability of traditional Chinese, Japanese and Sasang medicine...

  2. An economic perspective on the reliability of lighting systems in building with highly efficient energy: A case study

    International Nuclear Information System (INIS)

    Salata, F.; Lieto Vollaro, A. de; Ferraro, A.

    2014-01-01

    Highlights: • Proper design of efficient lighting systems. • The reliability and durability of the light sources. • Maintenance of lighting systems. • Quality standards of LED lamps. • Optimum economic choice of light sources. - Abstract: The performance of lighting system must be calculated in order to determine the energy requirements of the building. In the normative [EN 12464-1] are established lighting requirements which have effects on energy needs. The European standard [EN 15193] provides guidance on that evaluation. The easiest way to comply with reduction of energy requirements leads to the replacement of traditional lamps with LED ones, but if we calculate also the reliability parameters, the economic return is not guaranteed. Using bibliographic data, we have compared lighting’s results for a museum (LED lamps versus CFL and halogen lamps). The objective function of the study is to optimize the energy consumption of lighting systems, but at the same time to assess the reliability (MTTF of the lamps) of these systems. Without accurate information about this last parameters, the right choice of the lamps cannot be done successfully

  3. A single lithium-ion battery protection circuit with high reliability and low power consumption

    International Nuclear Information System (INIS)

    Jiang Jinguang; Li Sen

    2014-01-01

    A single lithium-ion battery protection circuit with high reliability and low power consumption is proposed. The protection circuit has high reliability because the voltage and current of the battery are controlled in a safe range. The protection circuit can immediately activate a protective function when the voltage and current of the battery are beyond the safe range. In order to reduce the circuit's power consumption, a sleep state control circuit is developed. Additionally, the output frequency of the ring oscillation can be adjusted continuously and precisely by the charging capacitors and the constant-current source. The proposed protection circuit is fabricated in a 0.5 μm mixed-signal CMOS process. The measured reference voltage is 1.19 V, the overvoltage is 4.2 V and the undervoltage is 2.2 V. The total power is about 9 μW. (semiconductor integrated circuits)

  4. Enhancing thermal reliability of fiber-optic sensors for bio-inspired applications at ultra-high temperatures

    Science.gov (United States)

    Kang, Donghoon; Kim, Heon-Young; Kim, Dae-Hyun

    2014-07-01

    The rapid growth of bio-(inspired) sensors has led to an improvement in modern healthcare and human-robot systems in recent years. Higher levels of reliability and better flexibility, essential features of these sensors, are very much required in many application fields (e.g. applications at ultra-high temperatures). Fiber-optic sensors, and fiber Bragg grating (FBG) sensors in particular, are being widely studied as suitable sensors for improved structural health monitoring (SHM) due to their many merits. To enhance the thermal reliability of FBG sensors, thermal sensitivity, generally expressed as αf + ξf and considered a constant, should be investigated more precisely. For this purpose, the governing equation of FBG sensors is modified using differential derivatives between the wavelength shift and the temperature change in this study. Through a thermal test ranging from RT to 900 °C, the thermal sensitivity of FBG sensors is successfully examined and this guarantees thermal reliability of FBG sensors at ultra-high temperatures. In detail, αf + ξf has a non-linear dependence on temperature and varies from 6.0 × 10-6 °C-1 (20 °C) to 10.6 × 10-6 °C-1 (650 °C). Also, FBGs should be carefully used for applications at ultra-high temperatures due to signal disappearance near 900 °C.

  5. The Multicultural Quality of Life Index: presentation and validation.

    Science.gov (United States)

    Mezzich, Juan E; Cohen, Neal L; Ruiperez, Maria A; Banzato, Claudio E M; Zapata-Vega, Maria I

    2011-04-01

    Quality of life has emerged as a crucial concept for the assessment of health and the planning of health care. Desirable features for the evaluation of quality of life include comprehensiveness, self-ratedness, cultural sensitivity, practicality and psychometric soundness. An attempt to meet these challenges led to the development of a brief multicultural quality of life instrument and to the appraisal of its applicability, reliability and validity. The development of the proposed assessment instrument was based on a wide review of the literature and the engagement of a multicultural mental health scholarly team. Its validation was conducted on samples of psychiatric patients (n = 124) and hospital professionals (n = 53) in New York City. A new generic culture-informed and self-rate instrument, the Multicultural Quality of Life Index, has been developed. Its 10 items cover key aspects of the concept, from physical well-being to spiritual fulfilment. Concerning its applicability, mean time for completion was less than 3 minutes and 96% of raters found it easy to use. Test-retest reliability was high (r = 0.87). A Cronbach's α of 0.92 documented its internal consistency and a factor analysis revealed a strong structure. With regard to discriminant validity, a highly significant difference was found between the mean total scores of professionals (x = 8.41) and patients (x = 6.34) presumed to have different levels of quality of life. The Multicultural Quality of Life Index is a brief and culturally informed instrument that appears to be easy to complete, reliable, internally consistent and valid. © 2011 Blackwell Publishing Ltd.

  6. Safety and reliability of automatization software

    Energy Technology Data Exchange (ETDEWEB)

    Kapp, K; Daum, R [Karlsruhe Univ. (TH) (Germany, F.R.). Lehrstuhl fuer Angewandte Informatik, Transport- und Verkehrssysteme

    1979-02-01

    Automated technical systems have to meet very high requirements concerning safety, security and reliability. Today, modern computers, especially microcomputers, are used as integral parts of those systems. In consequence computer programs must work in a safe and reliable mannter. Methods are discussed which allow to construct safe and reliable software for automatic systems such as reactor protection systems and to prove that the safety requirements are met. As a result it is shown that only the method of total software diversification can satisfy all safety requirements at tolerable cost. In order to achieve a high degree of reliability, structured and modular programming in context with high level programming languages are recommended.

  7. The Turkish adaptation of scale to measure patient perceptions of the quality of nursing care and related hospital services: A validity and reliability study.

    Science.gov (United States)

    Oren, Besey; Zengin, Neriman; Yildiz, Nebahat

    2016-01-01

    This study aimed to test the validity and reliability of a version of the tool developed in Sri Lanka in 2011 to assess patient perceptions of the quality of nursing care and related hospital services created for use with Turkish patients. This methodological study was conducted between November 2013 and November 2014 after obtaining ethical approval and organizational permission. Data was collected during discharge from 180 adult patients who were hospitalized for at least 3 days at a medical school hospital located in Istanbul. After language validation, validity and reliability analyses of the scale were conducted. Content validity, content validity index (CVI), construct validity, and exploratory factor analysis were assessed and examined, and reliability was tested using the Cronbach's alpha coefficient and item-total correlations. Mean CVI was found to be 0.95, which is above expected value. Exploratory factor analysis revealed 4 factors with eigenvalues above 1, which explained 82.4% of total variance in the Turkish version of the tool to measure patient perceptions of nursing care and other hospital services. Factor loading for each item was ≥.40. Cronbach's alpha coefficient of sub-dimensions and total scale were found to be 0.84-0.98 and 0.98, respectively. Item-total correlations ranged from 0.56 to 0.83 for the entire group, which was above expected values. The Turkish version of the scale to assess patient perceptions of the quality of nursing care and related hospital services, which comprised 4 sub-dimensions and 36 items, was found to be valid and reliable for use with the Turkish population.

  8. Human Reliability Program Overview

    Energy Technology Data Exchange (ETDEWEB)

    Bodin, Michael

    2012-09-25

    This presentation covers the high points of the Human Reliability Program, including certification/decertification, critical positions, due process, organizational structure, program components, personnel security, an overview of the US DOE reliability program, retirees and academia, and security program integration.

  9. Development of high speed and reliable data transmission system for industrial CT

    International Nuclear Information System (INIS)

    Gao Fuqiang; Dong Yanli; Liu Guohua

    2010-01-01

    In order to meet the requirements of large capacity,high speed and high reliability of data transmission for industrial CT, a data transmission system based on USB 2.0 was designed. In the process of data transmission, FPGA was the main controller, and USB 2.0 CY7C68013A worked in slave FIFO mode. The system sent the data got from data acquisition system to host computer for image reconstruction. The testing results show that the transmission rate can reach 33 MB/s and the precision is 100%. The system satisfies the requirements of data transmission for industrial CT. (authors)

  10. Quality Assurance Strategy for Existing Homes: Final Quality Management Primer for High Performing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Del Bianco, M.; Taggart, J.; Sikora, J.; Wood, A.

    2012-12-01

    This guide is designed to help Building America (BA) Teams understand quality management and its role in transitioning from conventional to high performance home building and remodeling. It explains what quality means, the value of quality management systems, the unique need for QMS when building high performing homes, and the first steps to a implementing a comprehensive QMS. This document provides a framework and context for BA teams when they encounter builders and remodelers.

  11. Quality Assurance Strategy for Existing Homes. Final Quality Management Primer for High Performing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Del Bianco, M. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Taggart, J. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Sikora, J. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Wood, A. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States)

    2012-12-01

    This guide is designed to help Building America (BA) teams understand quality management and its role in transitioning from conventional to high performance home building and remodeling. It explains what quality means, the value of quality management systems, the unique need for QMS when building high performing homes, and the first steps to a implementing a comprehensive QMS. This document provides a framework and context for BA teams when they encounter builders and remodelers.

  12. Assessment of quality of prescribing in patients of hypertension at primary and secondary health care facilities using the Prescription Quality Index (PQI) tool.

    Science.gov (United States)

    Suthar, Jalpa Vashishth; Patel, Varsha J

    2014-01-01

    To determine the quality of prescribing in hypertension in primary and secondary health care settings using the Prescription Quality Index (PQI) tool and to assess the reliability of this tool. An observational cross-sectional study was carried out for 6 months in order to assess quality of prescribing of antihypertensive drugs using Prescription Quality Index (PQI) at four primary (PHC) and two secondary (SHC) health care facilities. Patients attending these facilities for at least 3 months were included. Complete medical history and prescriptions received were noted. Total and criteria wise PQI scores were derived for each prescription. Prescriptions were categorized as poor (score of ≤31), medium (score 32-33) and high quality (score 34-43) based on PQI total score. Psychometric analysis using factor analysis was carried out to assess reliability and validity. Total 73 hypertensive patients were included. Mean age was 61.2 ± 11 years with 35 (48%) patients above 65 years of age. Total PQI score was 26 ± 11. There was a significant difference in PQI score between PHC and SHC (P hypertensive patients was poor, somewhat better in primary as compared to secondary health care facility. PQI is reliable for measuring prescribing quality in hypertension in Indian set up.

  13. Reliability and validity of risk analysis

    International Nuclear Information System (INIS)

    Aven, Terje; Heide, Bjornar

    2009-01-01

    In this paper we investigate to what extent risk analysis meets the scientific quality requirements of reliability and validity. We distinguish between two types of approaches within risk analysis, relative frequency-based approaches and Bayesian approaches. The former category includes both traditional statistical inference methods and the so-called probability of frequency approach. Depending on the risk analysis approach, the aim of the analysis is different, the results are presented in different ways and consequently the meaning of the concepts reliability and validity are not the same.

  14. A high reliability oxygen deficiency monitoring system

    International Nuclear Information System (INIS)

    Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.

    1993-05-01

    The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings

  15. A high reliability oxygen deficiency monitoring system

    International Nuclear Information System (INIS)

    Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.

    1993-01-01

    The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings

  16. RF-MEMS capacitive switches with high reliability

    Science.gov (United States)

    Goldsmith, Charles L.; Auciello, Orlando H.; Carlisle, John A.; Sampath, Suresh; Sumant, Anirudha V.; Carpick, Robert W.; Hwang, James; Mancini, Derrick C.; Gudeman, Chris

    2013-09-03

    A reliable long life RF-MEMS capacitive switch is provided with a dielectric layer comprising a "fast discharge diamond dielectric layer" and enabling rapid switch recovery, dielectric layer charging and discharging that is efficient and effective to enable RF-MEMS switch operation to greater than or equal to 100 billion cycles.

  17. 78 FR 69018 - Improving the Resiliency of Mobile Wireless Communications Networks; Reliability and Continuity...

    Science.gov (United States)

    2013-11-18

    ... consumers value overall network reliability and quality in selecting mobile wireless service providers, they...-125] Improving the Resiliency of Mobile Wireless Communications Networks; Reliability and Continuity... (Reliability NOI) in 2011 to ``initiate a comprehensive examination of issues regarding the reliability...

  18. High Speed Simulation Framework for Reliable Logic Programs

    International Nuclear Information System (INIS)

    Lee, Wan-Bok; Kim, Seog-Ju

    2006-01-01

    This paper shows a case study of designing a PLC logic simulator that was developed to simulate and verify PLC control programs for nuclear plant systems. The nuclear control system requires strict restrictions rather than normal process control system does, since it works with nuclear power plants requiring high reliability under severe environment. One restriction is the safeness of the control programs which can be assured by exploiting severe testing. Another restriction is the simulation speed of the control programs, that should be fast enough to control multi devices concurrently in real-time. To cope with these restrictions, we devised a logic compiler which generates C-code programs from given PLC logic programs. Once the logic program was translated into C-code, the program could be analyzed by conventional software analysis tools and could be used to construct a fast logic simulator after cross-compiling, in fact, that is a kind of compiled-code simulation

  19. Highly Efficient and Reliable Transparent Electromagnetic Interference Shielding Film.

    Science.gov (United States)

    Jia, Li-Chuan; Yan, Ding-Xiang; Liu, Xiaofeng; Ma, Rujun; Wu, Hong-Yuan; Li, Zhong-Ming

    2018-04-11

    Electromagnetic protection in optoelectronic instruments such as optical windows and electronic displays is challenging because of the essential requirements of a high optical transmittance and an electromagnetic interference (EMI) shielding effectiveness (SE). Herein, we demonstrate the creation of an efficient transparent EMI shielding film that is composed of calcium alginate (CA), silver nanowires (AgNWs), and polyurethane (PU), via a facile and low-cost Mayer-rod coating method. The CA/AgNW/PU film with a high optical transmittance of 92% achieves an EMI SE of 20.7 dB, which meets the requirements for commercial shielding applications. A superior EMI SE of 31.3 dB could be achieved, whereas the transparent film still maintains a transmittance of 81%. The integrated efficient EMI SE and high transmittance are superior to those of most previously reported transparent EMI shielding materials. Moreover, our transparent films exhibit a highly reliable shielding ability in a complex service environment, with 98 and 96% EMI SE retentions even after 30 min of ultrasound treatment and 5000 bending cycles (1.5 mm radius), respectively. The comprehensive performance that is associated with the facile fabrication strategy imparts the CA/AgNW/PU film with great potential as an optimized EMI shielding material in emerging optoelectronic devices, such as flexible solar cells, displays, and touch panels.

  20. R&D program benefits estimation: DOE Office of Electricity Delivery and Energy Reliability

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2006-12-04

    The overall mission of the U.S. Department of Energy’s Office of Electricity Delivery and Energy Reliability (OE) is to lead national efforts to modernize the electric grid, enhance the security and reliability of the energy infrastructure, and facilitate recovery from disruptions to the energy supply. In support of this mission, OE conducts a portfolio of research and development (R&D) activities to advance technologies to enhance electric power delivery. Multiple benefits are anticipated to result from the deployment of these technologies, including higher quality and more reliable power, energy savings, and lower cost electricity. In addition, OE engages State and local government decision-makers and the private sector to address issues related to the reliability and security of the grid, including responding to national emergencies that affect energy delivery. The OE R&D activities are comprised of four R&D lines: High Temperature Superconductivity (HTS), Visualization and Controls (V&C), Energy Storage and Power Electronics (ES&PE), and Distributed Systems Integration (DSI).

  1. Analysis and recommendations for a reliable programming of software based safety systems

    International Nuclear Information System (INIS)

    Nunez McLeod, J.; Nunez McLeod, J.E.; Rivera, S.S.

    1997-01-01

    The present paper summarizes the results of several studies performed for the development of high software on i486 microprocessors, towards its utilization for control and safety systems for nuclear power plants. The work is based on software programmed in C language. Several recommendations oriented to high reliability software are analyzed, relating the requirements on high level language to its influence on assembler level. Several metrics are implemented, that allow for the quantification of the results achieved. New metrics were developed and other were adapted, in order to obtain more efficient indexes for the software description. Such metrics are helpful to visualize the adaptation of the software under development to the quality rules under use. A specific program developed to assist the reliability analyst on this quantification is also present in the paper. It performs the analysis of an executable program written in C language, disassembling it and evaluating its inter al structures. (author)

  2. Inequality in Preschool Quality? Community-Level Disparities in Access to High-Quality Learning Environments

    Science.gov (United States)

    Bassok, Daphna; Galdo, Eva

    2016-01-01

    In recent years, unequal access to high-quality preschool has emerged as a growing public policy concern. Because of data limitations, it is notoriously difficult to measure disparities in access to early learning opportunities across communities and particularly challenging to quantify gaps in access to "high-quality" programs. Research…

  3. Estimating the Parameters of Software Reliability Growth Models Using the Grey Wolf Optimization Algorithm

    OpenAIRE

    Alaa F. Sheta; Amal Abdel-Raouf

    2016-01-01

    In this age of technology, building quality software is essential to competing in the business market. One of the major principles required for any quality and business software product for value fulfillment is reliability. Estimating software reliability early during the software development life cycle saves time and money as it prevents spending larger sums fixing a defective software product after deployment. The Software Reliability Growth Model (SRGM) can be used to predict the number of...

  4. Reliability of cervical lordosis measurement techniques on long-cassette radiographs.

    Science.gov (United States)

    Janusz, Piotr; Tyrakowski, Marcin; Yu, Hailong; Siemionow, Kris

    2016-11-01

    Lateral radiographs are commonly used to assess cervical sagittal alignment. Three assessment methods have been described and are commonly utilized in clinical practice. These methods are described for perfect lateral cervical radiographs, however in everyday practice radiograph quality varies. The aim of this study was to compare the reliability and reproducibility of 3 cervical lordosis (CL) measurement methods. Forty-four standing lateral radiographs were randomly chosen from a lateral long-cassette radiograph database. Measurements of CL were performed with: Cobb method C2-C7 (CM), C2-C7 posterior tangent method (PTM), sum of posterior tangent method for each segment (SPTM). Three independent orthopaedic surgeons measured CL using the three methods on 44 lateral radiographs. One researcher used the three methods to measured CL three times at 4-week time intervals. Agreement between the methods as well as their intra- and interobserver reliability were tested and quantified by intraclass correlation coefficient (ICC) and median error for a single measurement (SEM). ICC of 0.75 or more reflected an excellent agreement/reliability. The results were compared with repeated ANOVA test, with p  0.05). All three methods appeared to be highly reliable. Although, high agreement between all measurement methods was shown, we do not recommend using Cobb measurement method interchangeably with PTM or SPTM within a single study as this could lead to error, whereas, such a comparison between tangent methods can be considered.

  5. Novel Low Cost, High Reliability Wind Turbine Drivetrain

    Energy Technology Data Exchange (ETDEWEB)

    Chobot, Anthony; Das, Debarshi; Mayer, Tyler; Markey, Zach; Martinson, Tim; Reeve, Hayden; Attridge, Paul; El-Wardany, Tahany

    2012-09-13

    Clipper Windpower, in collaboration with United Technologies Research Center, the National Renewable Energy Laboratory, and Hamilton Sundstrand Corporation, developed a low-cost, deflection-compliant, reliable, and serviceable chain drive speed increaser. This chain and sprocket drivetrain design offers significant breakthroughs in the areas of cost and serviceability and addresses the key challenges of current geared and direct-drive systems. The use of gearboxes has proven to be challenging; the large torques and bending loads associated with use in large multi-MW wind applications have generally limited demonstrated lifetime to 8-10 years [1]. The large cost of gearbox replacement and the required use of large, expensive cranes can result in gearbox replacement costs on the order of $1M, representing a significant impact to overall cost of energy (COE). Direct-drive machines eliminate the gearbox, thereby targeting increased reliability and reduced life-cycle cost. However, the slow rotational speeds require very large and costly generators, which also typically have an undesirable dependence on expensive rare-earth magnet materials and large structural penalties for precise air gap control. The cost of rare-earth materials has increased 20X in the last 8 years representing a key risk to ever realizing the promised cost of energy reductions from direct-drive generators. A common challenge to both geared and direct drive architectures is a limited ability to manage input shaft deflections. The proposed Clipper drivetrain is deflection-compliant, insulating later drivetrain stages and generators from off-axis loads. The system is modular, allowing for all key parts to be removed and replaced without the use of a high capacity crane. Finally, the technology modularity allows for scalability and many possible drivetrain topologies. These benefits enable reductions in drivetrain capital cost by 10.0%, levelized replacement and O&M costs by 26.7%, and overall cost of

  6. Study on highly reliable digital communication technology of reactor nuclear measuring equipment

    International Nuclear Information System (INIS)

    Gu Pengfei; Huang Xiaojin

    2007-01-01

    To meet the need of highly reliable of reactor nuclear measuring equipment, in allusion to the idiographic request of nuclear measuring equipment, the actual technical development and the application in industrial field, we design a kind of redundancy communication net based on PROFIBUS, and a kind of communication interface module based on redundancy PROFIBUS communication, which link the nuclear measuring equipment and PROFIBUS communication net, and also lay a foundation for advanced research. (authors)

  7. Reliability of an interactive computer program for advance care planning.

    Science.gov (United States)

    Schubart, Jane R; Levi, Benjamin H; Camacho, Fabian; Whitehead, Megan; Farace, Elana; Green, Michael J

    2012-06-01

    Despite widespread efforts to promote advance directives (ADs), completion rates remain low. Making Your Wishes Known: Planning Your Medical Future (MYWK) is an interactive computer program that guides individuals through the process of advance care planning, explaining health conditions and interventions that commonly involve life or death decisions, helps them articulate their values/goals, and translates users' preferences into a detailed AD document. The purpose of this study was to demonstrate that (in the absence of major life changes) the AD generated by MYWK reliably reflects an individual's values/preferences. English speakers ≥30 years old completed MYWK twice, 4 to 6 weeks apart. Reliability indices were assessed for three AD components: General Wishes; Specific Wishes for treatment; and Quality-of-Life values (QoL). Twenty-four participants completed the study. Both the Specific Wishes and QoL scales had high internal consistency in both time periods (Knuder Richardson formula 20 [KR-20]=0.83-0.95, and 0.86-0.89). Test-retest reliability was perfect for General Wishes (κ=1), high for QoL (Pearson's correlation coefficient=0.83), but lower for Specific Wishes (Pearson's correlation coefficient=0.57). MYWK generates an AD where General Wishes and QoL (but not Specific Wishes) statements remain consistent over time.

  8. Reliability of an Interactive Computer Program for Advance Care Planning

    Science.gov (United States)

    Levi, Benjamin H.; Camacho, Fabian; Whitehead, Megan; Farace, Elana; Green, Michael J

    2012-01-01

    Abstract Despite widespread efforts to promote advance directives (ADs), completion rates remain low. Making Your Wishes Known: Planning Your Medical Future (MYWK) is an interactive computer program that guides individuals through the process of advance care planning, explaining health conditions and interventions that commonly involve life or death decisions, helps them articulate their values/goals, and translates users' preferences into a detailed AD document. The purpose of this study was to demonstrate that (in the absence of major life changes) the AD generated by MYWK reliably reflects an individual's values/preferences. English speakers ≥30 years old completed MYWK twice, 4 to 6 weeks apart. Reliability indices were assessed for three AD components: General Wishes; Specific Wishes for treatment; and Quality-of-Life values (QoL). Twenty-four participants completed the study. Both the Specific Wishes and QoL scales had high internal consistency in both time periods (Knuder Richardson formula 20 [KR-20]=0.83–0.95, and 0.86–0.89). Test-retest reliability was perfect for General Wishes (κ=1), high for QoL (Pearson's correlation coefficient=0.83), but lower for Specific Wishes (Pearson's correlation coefficient=0.57). MYWK generates an AD where General Wishes and QoL (but not Specific Wishes) statements remain consistent over time. PMID:22512830

  9. Low-quality birds do not display high-quality signals: The cysteine-pheomelanin mechanism of honesty

    Science.gov (United States)

    Galván, Ismael; Wakamatsu, Kazumasa; Camarero, Pablo R; Mateo, Rafael; Alonso-Alvarez, Carlos

    2015-01-01

    The mechanisms that make that the costs of producing high-quality signals are unaffordable to low-quality signalers are a current issue in animal communication. The size of the melanin-based bib of male house sparrows Passer domesticus honestly signals quality. We induced the development of new bibs while treating males with buthionine-sulfoximine (BSO), a substance that depletes the levels of the antioxidant glutathione (GSH) and the amino acid cysteine, two elements that switch melanogenesis from eumelanin to pheomelanin. Final bib size is negatively related to pheomelanin levels in the bib feathers. BSO reduced cysteine and GSH levels in all birds, but improved phenotypes (bibs larger than controls) were only expressed by high-quality birds (BSO birds with largest bibs initially). Negative associations between final bib size and cysteine levels in erythrocytes, and between pheomelanin and cysteine levels, were observed in high-quality birds only. These findings suggest that a mechanism uncoupling pheomelanin and cysteine levels may have evolved in low-quality birds to avoid producing bibs of size not corresponding to their quality and greater relative costs. Indeed, greater oxidative stress in cells was not observed in low-quality birds. This may represent the first mechanism maintaining signal honesty without producing greater relative costs on low-quality signalers. PMID:25330349

  10. Safety and reliability assessment

    International Nuclear Information System (INIS)

    1979-01-01

    This report contains the papers delivered at the course on safety and reliability assessment held at the CSIR Conference Centre, Scientia, Pretoria. The following topics were discussed: safety standards; licensing; biological effects of radiation; what is a PWR; safety principles in the design of a nuclear reactor; radio-release analysis; quality assurance; the staffing, organisation and training for a nuclear power plant project; event trees, fault trees and probability; Automatic Protective Systems; sources of failure-rate data; interpretation of failure data; synthesis and reliability; quantification of human error in man-machine systems; dispersion of noxious substances through the atmosphere; criticality aspects of enrichment and recovery plants; and risk and hazard analysis. Extensive examples are given as well as case studies

  11. The reliability of physical examination tests for the clinical assessment of scapular dyskinesis in subjects with shoulder complaints: A systematic review.

    Science.gov (United States)

    Lange, Toni; Struyf, Filip; Schmitt, Jochen; Lützner, Jörg; Kopkow, Christian

    2017-07-01

    Systematic review. The aim of this systematic review was to summarize and evaluate intra- and interrater reliability research of physical examination tests used for the assessment of scapular dyskinesis. Scapular dyskinesis, defined as alteration of normal scapular kinematics, is described as a non-specific response to different shoulder pathologies. A systematic literature search was conducted in MEDLINE, EMBASE, AMED and PEDro until March 20th, 2015. Methodological quality was assessed with the Quality Appraisal of Reliability Studies (QAREL) by two independent reviewers. The search strategy revealed 3259 articles, of which 15 met the inclusion criteria. These studies evaluated the reliability of 41 test and test variations used for the assessment of scapular dyskinesis. This review identified a lack of high-quality studies evaluating intra- as well as interrater reliability of tests used for the assessment of scapular dyskinesis. In addition, reliability measures differed between included studies hindering proper cross-study comparisons. The effect of manual correction of the scapula on shoulder symptoms was evaluated in only one study, which is striking, since symptom alteration tests are used in routine care to guide further treatment. Thus, there is a strong need for further research in this area. Diagnosis, level 3a. Copyright © 2016. Published by Elsevier Ltd.

  12. Reliability and Measurement Error of Tensiomyography to Assess Mechanical Muscle Function: A Systematic Review.

    Science.gov (United States)

    Martín-Rodríguez, Saúl; Loturco, Irineu; Hunter, Angus M; Rodríguez-Ruiz, David; Munguia-Izquierdo, Diego

    2017-12-01

    Martín-Rodríguez, S, Loturco, I, Hunter, AM, Rodríguez-Ruiz, D, and Munguia-Izquierdo, D. Reliability and measurement error of tensiomyography to assess mechanical muscle function: A systematic review. J Strength Cond Res 31(12): 3524-3536, 2017-Interest in studying mechanical skeletal muscle function through tensiomyography (TMG) has increased in recent years. This systematic review aimed to (a) report the reliability and measurement error of all TMG parameters (i.e., maximum radial displacement of the muscle belly [Dm], contraction time [Tc], delay time [Td], half-relaxation time [½ Tr], and sustained contraction time [Ts]) and (b) to provide critical reflection on how to perform accurate and appropriate measurements for informing clinicians, exercise professionals, and researchers. A comprehensive literature search was performed of the Pubmed, Scopus, Science Direct, and Cochrane databases up to July 2017. Eight studies were included in this systematic review. Meta-analysis could not be performed because of the low quality of the evidence of some studies evaluated. Overall, the review of the 9 studies involving 158 participants revealed high relative reliability (intraclass correlation coefficient [ICC]) for Dm (0.91-0.99); moderate-to-high ICC for Ts (0.80-0.96), Tc (0.70-0.98), and ½ Tr (0.77-0.93); and low-to-high ICC for Td (0.60-0.98), independently of the evaluated muscles. In addition, absolute reliability (coefficient of variation [CV]) was low for all TMG parameters except for ½ Tr (CV = >20%), whereas measurement error indexes were high for this parameter. In conclusion, this study indicates that 3 of the TMG parameters (Dm, Td, and Tc) are highly reliable, whereas ½ Tr demonstrate insufficient reliability, and thus should not be used in future studies.

  13. Reliability and comparative validity of a Diet Quality Index for assessing dietary patterns of preschool-aged children in Sydney, Australia.

    Science.gov (United States)

    Kunaratnam, Kanita; Halaki, Mark; Wen, Li Ming; Baur, Louise A; Flood, Victoria M

    2018-03-01

    To report on the reliability and validity of a Diet Quality Index (DQI) to assess preschoolers dietary patterns using a short food frequency questionnaire (sFFQ) and 3-day food records (3d-FR). Seventy-seven preschool carers/parents completed a telephone interview on preschoolers (2-5-year olds) dietary habits in metropolitan Sydney. Agreement in scores was assessed using intraclass correlation (ICC) and paired t-tests for repeated sFFQ-DQI scores and Bland-Altman methods and paired t-tests for sFFQ-DQI and 3d-FR-DQI scores. Mean-total sFFQ-DQI ICC scores was high = 0.89, 95% CI (0.81, 0.93). There was weak agreement between sFFQ-DQI and 3d-FR-DQI scores (r = 0.36, p < 0.01). The 3d-FR-DQI scores were positively associated with carbohydrate, folate, ß-carotene, magnesium, calcium, protein, total fat and negatively associated with sugar, starch, niacin, vitamin C, phosphorus, polyunsaturated fat, and monounsaturated fat. The sFFQ-DQI demonstrated good reliability but weak validity. Associations between nutrients and 3d-FR-DQI scores indicate promising usability and warrants further investigation. Further research is needed to establish its validity in accurately scoring children's diet quality using sFFQ compared to 3d-FR before the tool can be implemented for use in population settings.

  14. Developing Reliable Life Support for Mars

    Science.gov (United States)

    Jones, Harry W.

    2017-01-01

    A human mission to Mars will require highly reliable life support systems. Mars life support systems may recycle water and oxygen using systems similar to those on the International Space Station (ISS). However, achieving sufficient reliability is less difficult for ISS than it will be for Mars. If an ISS system has a serious failure, it is possible to provide spare parts, or directly supply water or oxygen, or if necessary bring the crew back to Earth. Life support for Mars must be designed, tested, and improved as needed to achieve high demonstrated reliability. A quantitative reliability goal should be established and used to guide development t. The designers should select reliable components and minimize interface and integration problems. In theory a system can achieve the component-limited reliability, but testing often reveal unexpected failures due to design mistakes or flawed components. Testing should extend long enough to detect any unexpected failure modes and to verify the expected reliability. Iterated redesign and retest may be required to achieve the reliability goal. If the reliability is less than required, it may be improved by providing spare components or redundant systems. The number of spares required to achieve a given reliability goal depends on the component failure rate. If the failure rate is under estimated, the number of spares will be insufficient and the system may fail. If the design is likely to have undiscovered design or component problems, it is advisable to use dissimilar redundancy, even though this multiplies the design and development cost. In the ideal case, a human tended closed system operational test should be conducted to gain confidence in operations, maintenance, and repair. The difficulty in achieving high reliability in unproven complex systems may require the use of simpler, more mature, intrinsically higher reliability systems. The limitations of budget, schedule, and technology may suggest accepting lower and

  15. Modeling and Forecasting (Un)Reliable Realized Covariances for More Reliable Financial Decisions

    DEFF Research Database (Denmark)

    Bollerslev, Tim; Patton, Andrew J.; Quaedvlieg, Rogier

    We propose a new framework for modeling and forecasting common financial risks based on (un)reliable realized covariance measures constructed from high-frequency intraday data. Our new approach explicitly incorporates the effect of measurement errors and time-varying attenuation biases into the c......We propose a new framework for modeling and forecasting common financial risks based on (un)reliable realized covariance measures constructed from high-frequency intraday data. Our new approach explicitly incorporates the effect of measurement errors and time-varying attenuation biases...

  16. The reliability of physical examination tests for the diagnosis of anterior cruciate ligament rupture--A systematic review.

    Science.gov (United States)

    Lange, Toni; Freiberg, Alice; Dröge, Patrik; Lützner, Jörg; Schmitt, Jochen; Kopkow, Christian

    2015-06-01

    Systematic literature review. Despite their frequent application in routine care, a systematic review on the reliability of clinical examination tests to evaluate the integrity of the ACL is missing. To summarize and evaluate intra- and interrater reliability research on physical examination tests used for the diagnosis of ACL tears. A comprehensive systematic literature search was conducted in MEDLINE, EMBASE and AMED until May 30th 2013. Studies were included if they assessed the intra- and/or interrater reliability of physical examination tests for the integrity of the ACL. Methodological quality was evaluated with the Quality Appraisal of Reliability Studies (QAREL) tool by two independent reviewers. 110 hits were achieved of which seven articles finally met the inclusion criteria. These studies examined the reliability of four physical examination tests. Intrarater reliability was assessed in three studies and ranged from fair to almost perfect (Cohen's k = 0.22-1.00). Interrater reliability was assessed in all included studies and ranged from slight to almost perfect (Cohen's k = 0.02-0.81). The Lachman test is the physical tests with the highest intrarater reliability (Cohen's k = 1.00), the Lachman test performed in prone position the test with the highest interrater reliability (Cohen's k = 0.81). Included studies were partly of low methodological quality. A meta-analysis could not be performed due to the heterogeneity in study populations, reliability measures and methodological quality of included studies. Systematic investigations on the reliability of physical examination tests to assess the integrity of the ACL are scarce and of varying methodological quality. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Highly Reliable Organizations in the Onshore Natural Gas Sector: An Assessment of Current Practices, Regulatory Frameworks, and Select Case Studies

    Energy Technology Data Exchange (ETDEWEB)

    Logan, Jeffrey S. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Paranhos, Elizabeth [Energy Innovation Partners, Seattle, WA (United States); Kozak, Tracy G. [Energy Innovation Partners, Seattle, WA (United States); Boyd, William [Univ. of Colorado, Boulder, CO (United States)

    2017-07-31

    This study focuses on onshore natural gas operations and examines the extent to which oil and gas firms have embraced certain organizational characteristics that lead to 'high reliability' - understood here as strong safety and reliability records over extended periods of operation. The key questions that motivated this study include whether onshore oil and gas firms engaged in exploration and production (E&P) and midstream (i.e., natural gas transmission and storage) are implementing practices characteristic of high reliability organizations (HROs) and the extent to which any such practices are being driven by industry innovations and standards and/or regulatory requirements.

  18. The Chinese version of the Pediatric Quality of Life Inventory™ (PedsQL™ 3.0 Asthma Module: reliability and validity

    Directory of Open Access Journals (Sweden)

    Chen Ruoqing

    2011-08-01

    Full Text Available Abstract Background Health-related quality of life (HRQOL has been recognized as an important health outcome measurement for pediatric patients. One of the most promising instruments in measuring pediatric HRQOL emerged in recent years is the Pediatric Quality of Life Inventory (PedsQL™. The PedsQL™ 3.0 Asthma Module, one of the PedsQL™disease-specific scales, was designed to measure HRQOL dimensions specifically tailored for pediatric asthma. The present study is aimed to evaluate the psychometric properties of the Chinese version of the PedsQL™ 3.0 Asthma Module. Methods The PedsQL™ 3.0 Asthma Module was translated into Chinese following the PedsQL™ Measurement Model Translation Methodology. The Chinese version scale was administered to 204 children with asthma and 337 parents of children with asthma from four Triple A hospitals. The psychometric properties were then evaluated. Results The percentage of missing value for each item of the scale ranged from 0.00% to 8.31%. All child self-report subscales and parent proxy-report subscales approached or exceeded the minimum reliability standard of 0.70 for alpha coefficient, except 3 subscales of Young Child (aged 5-7 self-report (alphas ranging from 0.59 to 0.68. Test-retest reliability was satisfactory with intraclass correlation coefficients (ICCs which exceeded the recommended standard of 0.80 in all subscales. Correlation coefficients between items and their hypothesized subscales were higher than those with other subscales. The PedsQL™ 3.0 Asthma Module distinguished between outpatients and inpatients. Patients with mild asthma reported higher scores than those with moderate/severe asthma in majority of subscales. The intercorrelations among the PedsQL™ 3.0 Asthma Module subscales and the PedsQL™ 4.0 Generic Core Scales were in medium to large effect size. The child self-report scores were consistent with the parent proxy-report scores. Conclusions The Chinese version of

  19. Gearbox Reliability Collaborative High Speed Shaft Tapered Roller Bearing Calibration

    Energy Technology Data Exchange (ETDEWEB)

    Keller, J.; Guo, Y.; McNiff, B.

    2013-10-01

    The National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) is a project investigating gearbox reliability primarily through testing and modeling. Previous dynamometer testing focused upon acquiring measurements in the planetary section of the test gearbox. Prior to these tests, the strain gages installed on the planetary bearings were calibrated in a load frame.

  20. A reliable method for the quality control of 99mTc-MIBI prepared using fractionated cardiolite kits

    International Nuclear Information System (INIS)

    Poot, M.T.; Varelis, P.

    1998-01-01

    Full text: The reconstitution of fractionated Cardiolite kits with Na[ 99m Tc]TcO 4 eluted from a wet-column generator results in a preparation that contains elevated amounts of a polar radiochemical impurity, which is normally present in only trace amounts when such kits are reconstituted with eluate from a dry-column generator. We demonstrate, using HPLC, that this impurity causes a positive bias in several reported quality control methods (TLC, ITLC and SPE) for 99m Tc-MIBI, including that recommended by the manufacturer (TLC). A rapid procedure, based on a C18 solid phase extraction (SPE) cartridge, for measuring the radiochemical purity (RCP) of 99m Tc-MIBI samples was developed and compared with three other methods including HPLC. Over a RCP range of 49-98%, the values obtained using our SPE method deviated from those obtained using HPLC by 1.1+1.395 (n=26). In conclusion our SPE method is a rapid and reliable means of quality controlling 99m Tc-MIBI

  1. A reliable method for the quality control of 99mTc-MIBI prepared using fractionated cardiolite kits

    Energy Technology Data Exchange (ETDEWEB)

    Poot, M.T.; Varelis, P. [St George Hospital, Sydney, NSW (Australia). Department of Nuclear Medicine

    1998-06-01

    Full text: The reconstitution of fractionated Cardiolite kits with Na[{sup 99m}Tc]TcO{sub 4} eluted from a wet-column generator results in a preparation that contains elevated amounts of a polar radiochemical impurity, which is normally present in only trace amounts when such kits are reconstituted with eluate from a dry-column generator. We demonstrate, using HPLC, that this impurity causes a positive bias in several reported quality control methods (TLC, ITLC and SPE) for {sup 99m}Tc-MIBI, including that recommended by the manufacturer (TLC). A rapid procedure, based on a C18 solid phase extraction (SPE) cartridge, for measuring the radiochemical purity (RCP) of {sup 99m}Tc-MIBI samples was developed and compared with three other methods including HPLC. Over a RCP range of 49-98%, the values obtained using our SPE method deviated from those obtained using HPLC by 1.1+1.395 (n=26). In conclusion our SPE method is a rapid and reliable means of quality controlling {sup 99m}Tc-MIBI

  2. Enhancing thermal reliability of fiber-optic sensors for bio-inspired applications at ultra-high temperatures

    International Nuclear Information System (INIS)

    Kang, Donghoon; Kim, Heon-Young; Kim, Dae-Hyun

    2014-01-01

    The rapid growth of bio-(inspired) sensors has led to an improvement in modern healthcare and human–robot systems in recent years. Higher levels of reliability and better flexibility, essential features of these sensors, are very much required in many application fields (e.g. applications at ultra-high temperatures). Fiber-optic sensors, and fiber Bragg grating (FBG) sensors in particular, are being widely studied as suitable sensors for improved structural health monitoring (SHM) due to their many merits. To enhance the thermal reliability of FBG sensors, thermal sensitivity, generally expressed as α f + ξ f and considered a constant, should be investigated more precisely. For this purpose, the governing equation of FBG sensors is modified using differential derivatives between the wavelength shift and the temperature change in this study. Through a thermal test ranging from RT to 900 °C, the thermal sensitivity of FBG sensors is successfully examined and this guarantees thermal reliability of FBG sensors at ultra-high temperatures. In detail, α f + ξ f has a non-linear dependence on temperature and varies from 6.0 × 10 −6  °C −1 (20 °C) to 10.6 × 10 −6  °C −1 (650 °C). Also, FBGs should be carefully used for applications at ultra-high temperatures due to signal disappearance near 900 °C. (paper)

  3. Reliability and Validity of the English-, Chinese- and Malay-Language Versions of the World Health Organization Quality of Life (WHOQOL-BREF) Questionnaire in Singapore.

    Science.gov (United States)

    Cheung, Yin Bun; Yeo, Khung Keong; Chong, Kok Joon; Khoo, Eric Yh; Wee, Hwee Lin

    2017-12-01

    The World Health Organization Quality of Life (WHOQOL-BREF) questionnaire is a 26-item questionnaire that evaluates 4 domains of quality of life (QoL), namely Physical, Psychological, Social Relationships and Environment. This study aimed to evaluate the validity and reliability of the WHOQOL-BREF among Singapore residents aged 21 and above. We recruited participants from the general population by using multistage cluster sampling and participants from 2 hospitals by using convenience sampling. Participants completed either English, Chinese or Malay versions of the WHOQOL-BREF and the EuroQoL 5 Dimension 5 Levels (EQ-5D-5L) questionnaires. Confirmatory factor analysis, known-group validity, internal consistency (Cronbach's alpha) and test-retest reliability using the intraclass correlation coefficient (ICC) were performed. Data from 1316 participants were analysed (Chinese: 46.9%, Malay: 41.0% and Indian: 11.7%; 57.5% mean, mean standard deviation [SD, range] age: 51.9 [15.68, 24 to 90] years); 154 participants took part in the retest in various languages (English: 60, Chinese: 49 and Malay: 45). Tucker-Lewis Index (TLI) was 0.919, 0.913 and 0.909 for the English, Chinese and Malay versions, respectively. Cronbach's alpha exceeded 0.7 and ICC exceeded 0.4 for all domains in all language versions. The WHOQOL-BREF is valid and reliable for assessing QoL in Singapore. Model fit is reasonable with room for improvement.

  4. Are chiropractic tests for the lumbo-pelvic spine reliable and valid? A systematic critical literature review

    DEFF Research Database (Denmark)

    Hestbaek, L; Leboeuf-Yde, C

    2000-01-01

    OBJECTIVE: To systematically review the peer-reviewed literature about the reliability and validity of chiropractic tests used to determine the need for spinal manipulative therapy of the lumbo-pelvic spine, taking into account the quality of the studies. DATA SOURCES: The CHIROLARS database......-pelvic spine were included. DATA EXTRACTION: Data quality were assessed independently by the two reviewers, with a quality score based on predefined methodologic criteria. Results of the studies were then evaluated in relation to quality. DATA SYNTHESIS: None of the tests studied had been sufficiently...... evaluated in relation to reliability and validity. Only tests for palpation for pain had consistently acceptable results. Motion palpation of the lumbar spine might be valid but showed poor reliability, whereas motion palpation of the sacroiliac joints seemed to be slightly reliable but was not shown...

  5. Emblems of Quality in Higher Education. Developing and Sustaining High-Quality Programs.

    Science.gov (United States)

    Haworth, Jennifer Grant; Conrad, Clifton F.

    This book proposes an "engagement" theory of program quality to evaluate and improve higher education programs at all degree levels. Based on interviews with 781 participants in a national study of Masters degree programs, it focuses on the interactive roles of students, faculty, and administrators in developing high-quality programs…

  6. Development and evaluation of oral Cancer quality-of-life questionnaire (QOL-OC).

    Science.gov (United States)

    Nie, Min; Liu, Chang; Pan, Yi-Chen; Jiang, Chen-Xi; Li, Bao-Ru; Yu, Xi-Jie; Wu, Xin-Yu; Zheng, Shu-Ning

    2018-05-03

    In this study scales and items for the Oral Cancer Quality-of-life Questionnaire (QOL-OC) were designed and the instrument was evaluated. The QOL-OC was developed and modified using the international definition of quality of life (QOL) promulgated by the European Organization for Research and Treatment of Cancer (EORTC) and analysis of the precedent measuring instruments. The contents of each item were determined in the context of the specific characteristics of oral cancer. Two hundred thirteen oral cancer patients were asked to complete both the EORTC core quality of life questionnaire (EORTC QLC-C30) and the QOL-OC. Data collected was used to conduct factor analysis, test-retest reliability, internal consistency, and construct validity. Questionnaire compliance was relatively high. Fourteen of the 213 subjects accepted the same tests after 24 to 48 h demonstrating a high test-retest reliability for all five scales. Overall internal consistency surpasses 0.8. The outcome of the factor analysis coincides substantially with our theoretical conception. Each item shows a higher correlation coefficient within its own scale than the others which indicates high construct validity. QOL-OC demonstrates fairly good statistical reliability, validity, and feasibility. However, further tests and modification are needed to ensure its applicability to the quality-of-life assessment of Chinese oral cancer patients.

  7. An Inventory Model for Deteriorating Item with Reliability Consideration and Trade Credit

    Directory of Open Access Journals (Sweden)

    S. R. Singh

    2014-10-01

    Full Text Available In today’s global market every body want to buy products of high level quality and to achieve a high level product quality supplier have to invest in improving reliability of production process. In present article we have studies reliable production process with stock dependent unit production and holding cost. Demand is exponential function of time and infinite production process wit non- instantaneous deterioration rate are considered in this paper. Whole study has been done under the effect of trade credit. The main objective of this paper is to optimize the total relevant cost for reliable production process. Numerical example and sensitivity analysis is given at the end of this paper.   Normal 0 false false false EN-US X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin-top:0in; mso-para-margin-right:0in; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0in; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin;}

  8. Publishing nutrition research: validity, reliability, and diagnostic test assessment in nutrition-related research.

    Science.gov (United States)

    Gleason, Philip M; Harris, Jeffrey; Sheean, Patricia M; Boushey, Carol J; Bruemmer, Barbara

    2010-03-01

    This is the sixth in a series of monographs on research design and analysis. The purpose of this article is to describe and discuss several concepts related to the measurement of nutrition-related characteristics and outcomes, including validity, reliability, and diagnostic tests. The article reviews the methodologic issues related to capturing the various aspects of a given nutrition measure's reliability, including test-retest, inter-item, and interobserver or inter-rater reliability. Similarly, it covers content validity, indicators of absolute vs relative validity, and internal vs external validity. With respect to diagnostic assessment, the article summarizes the concepts of sensitivity and specificity. The hope is that dietetics practitioners will be able to both use high-quality measures of nutrition concepts in their research and recognize these measures in research completed by others. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  9. Plastic Encapsulated Microcircuits (PEMs) Reliability Guide

    Science.gov (United States)

    Sandor, M.

    2000-01-01

    It is reported by some users and has been demonstrated by others via testing and qualification that the quality and reliability of plastic-encapsulated microcircuits (PEMs) manufactured today are excellent in commercial applications and closely equivalent, and in some cases superior to their hemetic counterparts.

  10. Advanced RESTART method for the estimation of the probability of failure of highly reliable hybrid dynamic systems

    International Nuclear Information System (INIS)

    Turati, Pietro; Pedroni, Nicola; Zio, Enrico

    2016-01-01

    The efficient estimation of system reliability characteristics is of paramount importance for many engineering applications. Real world system reliability modeling calls for the capability of treating systems that are: i) dynamic, ii) complex, iii) hybrid and iv) highly reliable. Advanced Monte Carlo (MC) methods offer a way to solve these types of problems, which are feasible according to the potentially high computational costs. In this paper, the REpetitive Simulation Trials After Reaching Thresholds (RESTART) method is employed, extending it to hybrid systems for the first time (to the authors’ knowledge). The estimation accuracy and precision of RESTART highly depend on the choice of the Importance Function (IF) indicating how close the system is to failure: in this respect, proper IFs are here originally proposed to improve the performance of RESTART for the analysis of hybrid systems. The resulting overall simulation approach is applied to estimate the probability of failure of the control system of a liquid hold-up tank and of a pump-valve subsystem subject to degradation induced by fatigue. The results are compared to those obtained by standard MC simulation and by RESTART with classical IFs available in the literature. The comparison shows the improvement in the performance obtained by our approach. - Highlights: • We consider the issue of estimating small failure probabilities in dynamic systems. • We employ the RESTART method to estimate the failure probabilities. • New Importance Functions (IFs) are introduced to increase the method performance. • We adopt two dynamic, hybrid, highly reliable systems as case studies. • A comparison with literature IFs proves the effectiveness of the new IFs.

  11. Robust against route failure using power proficient reliable routing in MANET

    Directory of Open Access Journals (Sweden)

    M. Malathi

    2018-03-01

    Full Text Available The aim of this paper was to propose a novel routing protocol for Mobile Adhoc Network communication which reduces the route failure during transmission. The proposed routing protocol uses 3 salient parameters to discover the path which ensure the reliable communication. The quality of the channel, link quality and energy level of the node are the major reasons for unintentional node failure in mobile Adhoc network. So the proposed routing protocol considers these three parameters to select the best forwarder node in the path. The reliable data communication is achieved by transmitting data via path selected by the proposed routing scheme has been proven using network simulator (NS2. Keywords: Channel quality, Link quality, Mobile Adhoc Network (MANET, Residual energy

  12. An Embedded System for Safe, Secure and Reliable Execution of High Consequence Software

    Energy Technology Data Exchange (ETDEWEB)

    MCCOY,JAMES A.

    2000-08-29

    As more complex and functionally diverse requirements are placed on high consequence embedded applications, ensuring safe and secure operation requires an execution environment that is ultra reliable from a system viewpoint. In many cases the safety and security of the system depends upon the reliable cooperation between the hardware and the software to meet real-time system throughput requirements. The selection of a microprocessor and its associated development environment for an embedded application has the most far-reaching effects on the development and production of the system than any other element in the design. The effects of this choice ripple through the remainder of the hardware design and profoundly affect the entire software development process. While state-of-the-art software engineering principles indicate that an object oriented (OO) methodology provides a superior development environment, traditional programming languages available for microprocessors targeted for deeply embedded applications do not directly support OO techniques. Furthermore, the microprocessors themselves do not typically support nor do they enforce an OO environment. This paper describes a system level approach for the design of a microprocessor intended for use in deeply embedded high consequence applications that both supports and enforces an OO execution environment.

  13. Long quantum channels for high-quality entanglement transfer

    International Nuclear Information System (INIS)

    Banchi, L; Apollaro, T J G; Cuccoli, A; Verrucchi, P; Vaia, R

    2011-01-01

    High-quality quantum-state and entanglement transfer can be achieved in an unmodulated spin bus operating in the ballistic regime, which occurs when the endpoint qubits A and B are nonperturbatively coupled to the chain by a suitable exchange interaction j 0 . Indeed, the transition amplitude characterizing the transfer quality exhibits a maximum for a finite optimal value j opt 0 (N), where N is the channel length. We show that j opt 0 (N) scales as N -1/6 for large N and that it ensures a high-quality entanglement transfer even in the limit of arbitrarily long channels, almost independently of the channel initialization. For instance, for any chain length the average quantum-state transmission fidelity exceeds 90% and decreases very little in a broad neighbourhood of j opt 0 (N). We emphasize that, taking the reverse point of view, should j 0 be experimentally constrained, high-quality transfer can still be obtained by adjusting the channel length to its optimal value. (paper)

  14. Quality assurance and quality control in mammography: A review

    International Nuclear Information System (INIS)

    BenComo, Jose A.

    2000-01-01

    A mammogram is among the most technically demanding radiographic procedures. The early detection of breast cancer relies on the radiologist's ability to perceive subtle changes in the image that are only perceptible with high-quality imaging. Early detection of breast cancer is only as reliable as the mammogram with which a diagnosis is made, and a mammogram is only as accurate as the system that produces it. A quality assurance (QA) program maximizes the likelihood that the mammographic images will provide adequate diagnostic information for the least possible radiation exposure and cost to the patient. The QA program monitors each phase of operation of the imaging facility beginning with the request for an examination and ending with the interpretation of the referring physician and ensures that the imaging equipment used for the examination will yield the information desired. Because image quality is the most important technical aspect of mammography, this review summarizes the most important QA and quality control issues

  15. Inter- and intrarater reliability of the Chicago Classification in pediatric high-resolution esophageal manometry recordings

    NARCIS (Netherlands)

    Singendonk, M. M. J.; Smits, M. J.; Heijting, I. E.; van Wijk, M. P.; Nurko, S.; Rosen, R.; Weijenborg, P. W.; Abu-Assi, R.; Hoekman, D. R.; Kuizenga-Wessel, S.; Seiboth, G.; Benninga, M. A.; Omari, T. I.; Kritas, S.

    2015-01-01

    The Chicago Classification (CC) facilitates interpretation of high-resolution manometry (HRM) recordings. Application of this adult based algorithm to the pediatric population is unknown. We therefore assessed intra and interrater reliability of software-based CC diagnosis in a pediatric cohort.

  16. Reliability and Maintainability Analysis of a High Air Pressure Compressor Facility

    Science.gov (United States)

    Safie, Fayssal M.; Ring, Robert W.; Cole, Stuart K.

    2013-01-01

    This paper discusses a Reliability, Availability, and Maintainability (RAM) independent assessment conducted to support the refurbishment of the Compressor Station at the NASA Langley Research Center (LaRC). The paper discusses the methodologies used by the assessment team to derive the repair by replacement (RR) strategies to improve the reliability and availability of the Compressor Station (Ref.1). This includes a RAPTOR simulation model that was used to generate the statistical data analysis needed to derive a 15-year investment plan to support the refurbishment of the facility. To summarize, study results clearly indicate that the air compressors are well past their design life. The major failures of Compressors indicate that significant latent failure causes are present. Given the occurrence of these high-cost failures following compressor overhauls, future major failures should be anticipated if compressors are not replaced. Given the results from the RR analysis, the study team recommended a compressor replacement strategy. Based on the data analysis, the RR strategy will lead to sustainable operations through significant improvements in reliability, availability, and the probability of meeting the air demand with acceptable investment cost that should translate, in the long run, into major cost savings. For example, the probability of meeting air demand improved from 79.7 percent for the Base Case to 97.3 percent. Expressed in terms of a reduction in the probability of failing to meet demand (1 in 5 days to 1 in 37 days), the improvement is about 700 percent. Similarly, compressor replacement improved the operational availability of the facility from 97.5 percent to 99.8 percent. Expressed in terms of a reduction in system unavailability (1 in 40 to 1 in 500), the improvement is better than 1000 percent (an order of magnitude improvement). It is worthy to note that the methodologies, tools, and techniques used in the LaRC study can be used to evaluate

  17. Emergency diesel generator reliability analysis high flux isotope reactor

    International Nuclear Information System (INIS)

    Merryman, L.; Christie, B.

    1993-01-01

    A program to apply some of the techniques of reliability engineering to the High Flux Isotope Reactor (HFIR) was started on August 8, 1992. Part of the program was to track the conditional probabilities of the emergency diesel generators responding to a valid demand. This was done to determine if the performance of the emergency diesel generators (which are more than 25 years old) has deteriorated. The conditional probabilities of the diesel generators were computed and trended for the period from May 1990 to December 1992. The calculations indicate that the performance of the emergency diesel generators has not deteriorated in recent years, i.e., the conditional probabilities of the emergency diesel generators have been fairly stable over the last few years. This information will be one factor than may be considered in the decision to replace the emergency diesel generators

  18. Performance of intraclass correlation coefficient (ICC) as a reliability index under various distributions in scale reliability studies.

    Science.gov (United States)

    Mehta, Shraddha; Bastero-Caballero, Rowena F; Sun, Yijun; Zhu, Ray; Murphy, Diane K; Hardas, Bhushan; Koch, Gary

    2018-04-29

    Many published scale validation studies determine inter-rater reliability using the intra-class correlation coefficient (ICC). However, the use of this statistic must consider its advantages, limitations, and applicability. This paper evaluates how interaction of subject distribution, sample size, and levels of rater disagreement affects ICC and provides an approach for obtaining relevant ICC estimates under suboptimal conditions. Simulation results suggest that for a fixed number of subjects, ICC from the convex distribution is smaller than ICC for the uniform distribution, which in turn is smaller than ICC for the concave distribution. The variance component estimates also show that the dissimilarity of ICC among distributions is attributed to the study design (ie, distribution of subjects) component of subject variability and not the scale quality component of rater error variability. The dependency of ICC on the distribution of subjects makes it difficult to compare results across reliability studies. Hence, it is proposed that reliability studies should be designed using a uniform distribution of subjects because of the standardization it provides for representing objective disagreement. In the absence of uniform distribution, a sampling method is proposed to reduce the non-uniformity. In addition, as expected, high levels of disagreement result in low ICC, and when the type of distribution is fixed, any increase in the number of subjects beyond a moderately large specification such as n = 80 does not have a major impact on ICC. Copyright © 2018 John Wiley & Sons, Ltd.

  19. Identifying suitable substrates for high-quality graphene-based heterostructures

    Science.gov (United States)

    Banszerus, L.; Janssen, H.; Otto, M.; Epping, A.; Taniguchi, T.; Watanabe, K.; Beschoten, B.; Neumaier, D.; Stampfer, C.

    2017-06-01

    We report on a scanning confocal Raman spectroscopy study investigating the strain-uniformity and the overall strain and doping of high-quality chemical vapour deposited (CVD) graphene-based heterostuctures on a large number of different substrate materials, including hexagonal boron nitride (hBN), transition metal dichalcogenides, silicon, different oxides and nitrides, as well as polymers. By applying a hBN-assisted, contamination free, dry transfer process for CVD graphene, high-quality heterostructures with low doping densities and low strain variations are assembled. The Raman spectra of these pristine heterostructures are sensitive to substrate-induced doping and strain variations and are thus used to probe the suitability of the substrate material for potential high-quality graphene devices. We find that the flatness of the substrate material is a key figure for gaining, or preserving high-quality graphene.

  20. Reliability of a visual scoring system with fluorescent tracers to assess dermal pesticide exposure.

    Science.gov (United States)

    Aragon, Aurora; Blanco, Luis; Lopez, Lylliam; Liden, Carola; Nise, Gun; Wesseling, Catharina

    2004-10-01

    We modified Fenske's semi-quantitative 'visual scoring system' of fluorescent tracer deposited on the skin of pesticide applicators and evaluated its reproducibility in the Nicaraguan setting. The body surface of 33 farmers, divided into 31 segments, was videotaped in the field after spraying with a pesticide solution containing a fluorescent tracer. A portable UV lamp was used for illumination in a foldaway dark room. The videos of five farmers were randomly selected. The scoring was based on a matrix with extension of fluorescent patterns (scale 0-5) on the ordinate and intensity (scale 0-5) on the abscissa, with the product of these two ranks as the final score for each body segment (0-25). Five medical students rated and evaluated the quality of 155 video images having undergone 4 h of training. Cronbach alpha coefficients and two-way random effects intraclass correlation coefficients (ICC) with absolute agreement were computed to assess inter-rater reliability. Consistency was high (Cronbach alpha = 0.96), but the scores differed substantially between raters. The overall ICC was satisfactory [0.75; 95% confidence interval (CI) = 0.62-0.83], but it was lower for intensity (0.54; 95% CI = 0.40-0.66) and higher for extension (0.80; 95% CI = 0.71-0.86). ICCs were lowest for images with low scores and evaluated as low quality, and highest for images with high scores and high quality. Inter-rater reliability coefficients indicate repeatability of the scoring system. However, field conditions for recording fluorescence should be improved to achieve higher quality images, and training should emphasize a better mechanism for the reading of body areas with low contamination.