WorldWideScience

Sample records for high quality current

  1. High-quality cardiopulmonary resuscitation: current and future directions.

    Science.gov (United States)

    Abella, Benjamin S

    2016-06-01

    Cardiopulmonary resuscitation (CPR) represents the cornerstone of cardiac arrest resuscitation care. Prompt delivery of high-quality CPR can dramatically improve survival outcomes; however, the definitions of optimal CPR have evolved over several decades. The present review will discuss the metrics of CPR delivery, and the evidence supporting the importance of CPR quality to improve clinical outcomes. The introduction of new technologies to quantify metrics of CPR delivery has yielded important insights into CPR quality. Investigations using CPR recording devices have allowed the assessment of specific CPR performance parameters and their relative importance regarding return of spontaneous circulation and survival to hospital discharge. Additional work has suggested new opportunities to measure physiologic markers during CPR and potentially tailor CPR delivery to patient requirements. Through recent laboratory and clinical investigations, a more evidence-based definition of high-quality CPR continues to emerge. Exciting opportunities now exist to study quantitative metrics of CPR and potentially guide resuscitation care in a goal-directed fashion. Concepts of high-quality CPR have also informed new approaches to training and quality improvement efforts for cardiac arrest care.

  2. High-Average, High-Peak Current Injector Design

    CERN Document Server

    Biedron, S G; Virgo, M

    2005-01-01

    There is increasing interest in high-average-power (>100 kW), um-range FELs. These machines require high peak current (~1 kA), modest transverse emittance, and beam energies of ~100 MeV. High average currents (~1 A) place additional constraints on the design of the injector. We present a design for an injector intended to produce the required peak currents at the injector, eliminating the need for magnetic compression within the linac. This reduces the potential for beam quality degradation due to CSR and space charge effects within magnetic chicanes.

  3. Ozone - Current Air Quality Index

    Science.gov (United States)

    GO! Local Air Quality Conditions Zip Code: State : My Current Location Current AQI Forecast AQI Loop More Maps AQI: Good (0 - 50) ... resources for Hawaii residents and visitors more announcements Air Quality Basics Air Quality Index | Ozone | Particle Pollution | Smoke ...

  4. Proposal for a race-track microtron with high peak current

    NARCIS (Netherlands)

    Ernst, G.J.; Haselhoff, E.H.; Witteman, W.J.; Botman, J.I.M.; van Genderen, W.; Hagedoorn, H.L.; van der Heide, J.A.; Kleeven, W.J.G.M.

    1989-01-01

    In order to obtain high gain in a free electron laser a high-quality electron beam with high peak current is required. It is well-known that a microtron is able to produce a high-quality beam having low emittance and small energy spread (1%). Because a circular microtron has a limited high-current

  5. The design of a five-cell high-current superconducting cavity

    International Nuclear Information System (INIS)

    Li Yongming; Zhu Feng; Quan Shengwen; Liu Kexin; Nassiri, Ali

    2012-01-01

    Energy recovery linacs are promising for achieving high average current with superior beam quality. The key component for accelerating such high-current beams is the superconducting radio-frequency cavity. The design of a 1.3 GHz five-cell high-current superconducting cavity has been carried out under cooperation between Peking University and the Argonne National Laboratory. The radio-frequency properties, damping of the higher order modes, multipacting and mechanical features of this cavity have been discussed and the final design is presented. (authors)

  6. Record high-average current from a high-brightness photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Dunham, Bruce; Barley, John; Bartnik, Adam; Bazarov, Ivan; Cultrera, Luca; Dobbins, John; Hoffstaetter, Georg; Johnson, Brent; Kaplan, Roger; Karkare, Siddharth; Kostroun, Vaclav; Li Yulin; Liepe, Matthias; Liu Xianghong; Loehl, Florian; Maxson, Jared; Quigley, Peter; Reilly, John; Rice, David; Sabol, Daniel [Cornell Laboratory for Accelerator-Based Sciences and Education, Cornell University, Ithaca, New York 14853 (United States); and others

    2013-01-21

    High-power, high-brightness electron beams are of interest for many applications, especially as drivers for free electron lasers and energy recovery linac light sources. For these particular applications, photoemission injectors are used in most cases, and the initial beam brightness from the injector sets a limit on the quality of the light generated at the end of the accelerator. At Cornell University, we have built such a high-power injector using a DC photoemission gun followed by a superconducting accelerating module. Recent results will be presented demonstrating record setting performance up to 65 mA average current with beam energies of 4-5 MeV.

  7. Eddy current quality control of soldered current-carrying busbar splices of superconducting magnets

    CERN Document Server

    Kogan, L; Savary, F; Principe, R; Datskov, V; Rozenfel'd, E; Khudjakov, B

    2015-01-01

    The eddy current technique associated with a U-shaped transducer is studied for the quality control of soldered joints between superconducting busbars ('splices'). Two other quality control techniques, based on X-rays and direct measurement of the electrical resistance, are also studied for comparison. A comparative analysis of the advantages and disadvantages of these three methods in relation to the quality control of soldered superconducting busbar cables enclosed in copper shells is used for benchmarking. The results of inspections with the U-shaped eddy current transducer carried out on several sample joints presenting different types of soldering defects show the potential of this type of nondestructive (ND) quality control technique.

  8. Current Indoor Air Quality in Japan.

    Science.gov (United States)

    Jinno, Hideto

    2016-01-01

    People spend more than two thirds of their daily time indoors. Hence, maintaining a healthy indoor environment is indispensable for the prevention of building related illness. In Japan, guidelines for indoor air quality have been established for 13 volatile/semi-volatile organic compounds (VOCs/SVOCs). These guidelines are now under revision by the Committee on Sick House Syndrome: Indoor Air Pollution. In order to gain information on the current indoor air pollutants and their levels, we carried out a nation-wide survey of VOCs and aldehydes in indoor residential air during 2012-2013. In this review, I concisely summarized the current indoor air quality of Japan.

  9. Power quality issues current harmonics

    CERN Document Server

    Mikkili, Suresh

    2015-01-01

    Power Quality Issues: Current Harmonics provides solutions for the mitigation of power quality problems related to harmonics. Focusing on active power filters (APFs) due to their excellent harmonic and reactive power compensation in two-wire (single phase), three-wire (three-phase without neutral), and four-wire (three-phase with neutral) AC power networks with nonlinear loads, the text:Introduces the APF technology, describing various APF configurations and offering guidelines for the selection of APFs for specific application considerationsCompares shunt active filter (SHAF) control strategi

  10. Optimizing Quality of Care and Patient Safety in Malaysia: The Current Global Initiatives, Gaps and Suggested Solutions

    OpenAIRE

    Jarrar, Mu?taman; Rahman, Hamzah Abdul; Don, Mohammad Sobri

    2015-01-01

    Background and Objective: Demand for health care service has significantly increased, while the quality of healthcare and patient safety has become national and international priorities. This paper aims to identify the gaps and the current initiatives for optimizing the quality of care and patient safety in Malaysia. Design: Review of the current literature. Highly cited articles were used as the basis to retrieve and review the current initiatives for optimizing the quality of care and patie...

  11. Algorithm for evaluating the effectiveness of a high-rise development project based on current yield

    Science.gov (United States)

    Soboleva, Elena

    2018-03-01

    The article is aimed at the issues of operational evaluation of development project efficiency in high-rise construction under the current economic conditions in Russia. The author touches the following issues: problems of implementing development projects, the influence of the operational evaluation quality of high-rise construction projects on general efficiency, assessing the influence of the project's external environment on the effectiveness of project activities under crisis conditions and the quality of project management. The article proposes the algorithm and the methodological approach to the quality management of the developer project efficiency based on operational evaluation of the current yield efficiency. The methodology for calculating the current efficiency of a development project for high-rise construction has been updated.

  12. Improvement of automatic control system for high-speed current collectors

    Science.gov (United States)

    Sidorov, O. A.; Goryunov, V. N.; Golubkov, A. S.

    2018-01-01

    The article considers the ways of regulation of pantographs to provide quality and reliability of current collection at high speeds. To assess impact of regulation was proposed integral criterion of the quality of current collection, taking into account efficiency and reliability of operation of the pantograph. The study was carried out using mathematical model of interaction of pantograph and catenary system, allowing to assess contact force and intensity of arcing at the contact zone at different movement speeds. The simulation results allowed us to estimate the efficiency of different methods of regulation of pantographs and determine the best option.

  13. Evidence for intrinsic critical current density in high Tc superconductors

    International Nuclear Information System (INIS)

    Freltoft, T.; Minnhagen, P.; Jeldtoft Jensen, H.

    1991-01-01

    We present measurements of the voltage-current characteristics of high quality epitaxial YBaCuO films in zero magnetic field. According to the predictions of a current induced vortex pair breaking picture the voltage should follow the functional form V∝I(I-I c ) a-1 . An analysis designed to test this functional behavior is carried out. Consistency is found. (orig.)

  14. High current ion sources

    International Nuclear Information System (INIS)

    Brown, I.G.

    1989-06-01

    The concept of high current ion source is both relative and evolutionary. Within the domain of one particular kind of ion source technology a current of microamperers might be 'high', while in another area a current of 10 Amperes could 'low'. Even within the domain of a single ion source type, what is considered high current performance today is routinely eclipsed by better performance and higher current output within a short period of time. Within their fields of application, there is a large number of kinds of ion sources that can justifiably be called high current. Thus, as a very limited example only, PIGs, Freemen sources, ECR sources, duoplasmatrons, field emission sources, and a great many more all have their high current variants. High current ion beams of gaseous and metallic species can be generated in a number of different ways. Ion sources of the kind developed at various laboratories around the world for the production of intense neutral beams for controlled fusion experiments are used to form large area proton deuteron beams of may tens of Amperes, and this technology can be used for other applications also. There has been significant progress in recent years in the use of microwave ion sources for high current ion beam generation, and this method is likely to find wide application in various different field application. Finally, high current beams of metal ions can be produced using metal vapor vacuum arc ion source technology. After a brief consideration of high current ion source design concepts, these three particular methods are reviewed in this paper

  15. High stability, high current DC-power supplies

    International Nuclear Information System (INIS)

    Hosono, K.; Hatanaka, K.; Itahashi, T.

    1995-01-01

    Improvements of the power supplies and the control system of the AVF cyclotron which is used as an injector to the ring cyclotron and of the transport system to the ring cyclotron were done in order to get more high quality and more stable beam. The power supply of the main coil of the AVF cyclotron was exchanged to new one. The old DCCTs (zero-flux current transformers) used for the power supplies of the trim coils of the AVF cyclotron were changed to new DCCTs to get more stability. The potentiometers used for the reference voltages in the other power supplies of the AVF cyclotron and the transport system were changed to the temperature controlled DAC method for numerical-value settings. This paper presents the results of the improvements. (author)

  16. High current, high bandwidth laser diode current driver

    Science.gov (United States)

    Copeland, David J.; Zimmerman, Robert K., Jr.

    1991-01-01

    A laser diode current driver has been developed for free space laser communications. The driver provides 300 mA peak modulation current and exhibits an optical risetime of less than 400 ps. The current and optical pulses are well behaved and show minimal ringing. The driver is well suited for QPPM modulation at data rates up to 440 Mbit/s. Much previous work has championed current steering circuits; in contrast, the present driver is a single-ended on/off switch. This results in twice the power efficiency as a current steering driver. The driver electrical efficiency for QPPM data is 34 percent. The high speed switch is realized with a Ku-band GaAsFET transistor, with a suitable pre-drive circuit, on a hybrid microcircuit adjacent to the laser diode.

  17. HIGH-CURRENT ERL-BASED ELECTRON COOLING FOR RHIC

    International Nuclear Information System (INIS)

    BEN-ZVI, I.

    2005-01-01

    The design of an electron cooler must take into account both electron beam dynamics issues as well as the electron cooling physics. Research towards high-energy electron cooling of RHIC is in its 3rd year at Brookhaven National Laboratory. The luminosity upgrade of RHIC calls for electron cooling of various stored ion beams, such as 100 GeV/A gold ions at collision energies. The necessary electron energy of 54 MeV is clearly out of reach for DC accelerator system of any kind. The high energy also necessitates a bunched beam, with a high electron bunch charge, low emittance and small energy spread. The Collider-Accelerator Department adopted the Energy Recovery Linac (ERL) for generating the high-current, high-energy and high-quality electron beam. The RHIC electron cooler ERL will use four Superconducting RF (SRF) 5-cell cavities, designed to operate at ampere-class average currents with high bunch charges. The electron source will be a superconducting, 705.75 MHz laser-photocathode RF gun, followed up by a superconducting Energy Recovery Linac (ERL). An R and D ERL is under construction to demonstrate the ERL at the unprecedented average current of 0.5 amperes. Beam dynamics performance and luminosity enhancement are described for the case of magnetized and non-magnetized electron cooling of RHIC

  18. Cryogenic high current discharges

    International Nuclear Information System (INIS)

    Meierovich, B.E.

    1994-01-01

    Z-pinches formed from frozen deuterium fibers by a rapidly rising current have enhanced stability and high neutron yield. The efforts to understand the enhanced stability and neutron yield on the basis of classical picture of Bennett equilibrium of the current channel has not given satisfactory results. The traditional approach does not take into account the essential difference between the frozen deuterium fiber Z-pinches and the usual Z-pinches such as exploding wires or classical gas-puffed Z-pinches. The very low temperature of the fiber atoms (10 K), together with the rapidly rising current, result in the coexistence of a high current channel with unionized fiber atoms for a substantial period of time. This phenomena lasts during the risetime. This approach takes into account the difference of the breakdown in a dielectric deuterium fiber and the breakdown in a metallic wire. This difference is essential to the understanding of specific features of cryogenic high current discharges. Z-pinches in frozen deuterium fibers should be considered as a qualitatively new phenomenon on the boundary of cryogenic and high current physics. It is a start of a new branch in plasma physics: the physics of cryogenic high current discharges

  19. Sleep quality and its relationship with quality of life among high-risk pregnant women (gestational diabetes and hypertension).

    Science.gov (United States)

    Saadati, Fatemeh; Sehhatiei Shafaei, Fahimeh; Mirghafourvand, Mozhgan

    2018-01-01

    Sleep is one of the most basic human requirements. This research aims at determining the status of sleep quality and its relationship with quality of life among high-risk pregnant women in Tabriz, Iran, in 2015. This research was a sectional study done on 364 qualified women in 28-36 weeks of pregnancy suffering from mild preeclampsia and gestational diabetes. The sampling was done as convenience. Personal-social-midwifery questionnaire, Pittsburg sleep quality, and quality of life in pregnancy (QOL-ORAV) were used for gathering data. Multivariate linear regression model was used for determining the relationship between sleep quality and its subsets with quality of life and controlling confounders. In the current study, the prevalence of sleep disturbance was 96.4%. Mean (SD) of the total score of sleep quality was 10.1 (4.1) and the total score of quality of life was 61.7 (17.3). According to Pearson's correlation test, there was statistically significant relationship between quality of life and sleep quality and all its subsets except sleep duration and use of sleep medication (p quality of life. The findings of current research show that sleep quality is low among high-risk pregnant women and quality of life is medium. So, it is necessary that required training is given by health cares for improving sleep quality and quality of life to mothers.

  20. Development of high temperature superconductors having high critical current density

    International Nuclear Information System (INIS)

    Hong, Gye Wong; Kim, C. J.; Lee, H.G.; Kwon, S. C.; Lee, H. J.; Kim, K. B.; Park, J. Y.; Jung, C. H.

    2000-08-01

    Fabrication of high T c superconductors and its applications for electric power device were carried out for developing superconductor application technologies. High quality YBCO superconductors was fabricated by melt texture growth, top-seeded melt growth process and multi-seeded melt growth process and the properties was compared. The critical current density of the melt processed YBCO superconductors was about few 10,000 A/cm 2 and the levitation force was 50 N. The processing time needed for the growth of the 123 single grain was greatly reduced by applying multi-seeding without no significant degradation of the levitation force. The multi-seeded melt growth process was confirmed as a time-saving and cost-effective method for the fabrication of bulk superconductors with controlled crystallographic orientation

  1. Development of high temperature superconductors having high critical current density

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Gye Wong; Kim, C. J.; Lee, H.G.; Kwon, S. C.; Lee, H. J.; Kim, K. B.; Park, J. Y.; Jung, C. H

    2000-08-01

    Fabrication of high T{sub c} superconductors and its applications for electric power device were carried out for developing superconductor application technologies. High quality YBCO superconductors was fabricated by melt texture growth, top-seeded melt growth process and multi-seeded melt growth process and the properties was compared. The critical current density of the melt processed YBCO superconductors was about few 10,000 A/cm{sup 2} and the levitation force was 50 N. The processing time needed for the growth of the 123 single grain was greatly reduced by applying multi-seeding without no significant degradation of the levitation force. The multi-seeded melt growth process was confirmed as a time-saving and cost-effective method for the fabrication of bulk superconductors with controlled crystallographic orientation.

  2. Optimizing Quality of Care and Patient Safety in Malaysia: The Current Global Initiatives, Gaps and Suggested Solutions.

    Science.gov (United States)

    Jarrar, Mu'taman; Abdul Rahman, Hamzah; Don, Mohammad Sobri

    2015-10-20

    Demand for health care service has significantly increased, while the quality of healthcare and patient safety has become national and international priorities. This paper aims to identify the gaps and the current initiatives for optimizing the quality of care and patient safety in Malaysia. Review of the current literature. Highly cited articles were used as the basis to retrieve and review the current initiatives for optimizing the quality of care and patient safety. The country health plan of Ministry of Health (MOH) Malaysia and the MOH Malaysia Annual Reports were reviewed. The MOH has set four strategies for optimizing quality and sustaining quality of life. The 10th Malaysia Health Plan promotes the theme "1 Care for 1 Malaysia" in order to sustain the quality of care. Despite of these efforts, the total number of complaints received by the medico-legal section of the MOH Malaysia is increasing. The current global initiatives indicted that quality performance generally belong to three main categories: patient; staffing; and working environment related factors. There is no single intervention for optimizing quality of care to maintain patient safety. Multidimensional efforts and interventions are recommended in order to optimize the quality of care and patient safety in Malaysia.

  3. Optimizing Quality of Care and Patient Safety in Malaysia: The Current Global Initiatives, Gaps and Suggested Solutions

    Science.gov (United States)

    Jarrar, Mu’taman; Rahman, Hamzah Abdul; Don, Mohammad Sobri

    2016-01-01

    Background and Objective: Demand for health care service has significantly increased, while the quality of healthcare and patient safety has become national and international priorities. This paper aims to identify the gaps and the current initiatives for optimizing the quality of care and patient safety in Malaysia. Design: Review of the current literature. Highly cited articles were used as the basis to retrieve and review the current initiatives for optimizing the quality of care and patient safety. The country health plan of Ministry of Health (MOH) Malaysia and the MOH Malaysia Annual Reports were reviewed. Results: The MOH has set four strategies for optimizing quality and sustaining quality of life. The 10th Malaysia Health Plan promotes the theme “1 Care for 1 Malaysia” in order to sustain the quality of care. Despite of these efforts, the total number of complaints received by the medico-legal section of the MOH Malaysia is increasing. The current global initiatives indicted that quality performance generally belong to three main categories: patient; staffing; and working environment related factors. Conclusions: There is no single intervention for optimizing quality of care to maintain patient safety. Multidimensional efforts and interventions are recommended in order to optimize the quality of care and patient safety in Malaysia. PMID:26755459

  4. High-voltage high-current triggering vacuum switch

    International Nuclear Information System (INIS)

    Alferov, D.F.; Bunin, R.A.; Evsin, D.V.; Sidorov, V.A.

    2012-01-01

    Experimental investigations of switching and breaking capacities of the new high current triggered vacuum switch (TVS) are carried out at various parameters of discharge current. It has been shown that the high current triggered vacuum switch TVS can switch repeatedly a current from units up to ten kiloampers with duration up to ten millisecond [ru

  5. Low-quality birds do not display high-quality signals: The cysteine-pheomelanin mechanism of honesty

    Science.gov (United States)

    Galván, Ismael; Wakamatsu, Kazumasa; Camarero, Pablo R; Mateo, Rafael; Alonso-Alvarez, Carlos

    2015-01-01

    The mechanisms that make that the costs of producing high-quality signals are unaffordable to low-quality signalers are a current issue in animal communication. The size of the melanin-based bib of male house sparrows Passer domesticus honestly signals quality. We induced the development of new bibs while treating males with buthionine-sulfoximine (BSO), a substance that depletes the levels of the antioxidant glutathione (GSH) and the amino acid cysteine, two elements that switch melanogenesis from eumelanin to pheomelanin. Final bib size is negatively related to pheomelanin levels in the bib feathers. BSO reduced cysteine and GSH levels in all birds, but improved phenotypes (bibs larger than controls) were only expressed by high-quality birds (BSO birds with largest bibs initially). Negative associations between final bib size and cysteine levels in erythrocytes, and between pheomelanin and cysteine levels, were observed in high-quality birds only. These findings suggest that a mechanism uncoupling pheomelanin and cysteine levels may have evolved in low-quality birds to avoid producing bibs of size not corresponding to their quality and greater relative costs. Indeed, greater oxidative stress in cells was not observed in low-quality birds. This may represent the first mechanism maintaining signal honesty without producing greater relative costs on low-quality signalers. PMID:25330349

  6. Measurement technology of RF interference current in high current system

    Science.gov (United States)

    Zhao, Zhihua; Li, Jianxuan; Zhang, Xiangming; Zhang, Lei

    2018-06-01

    Current probe is a detection method commonly used in electromagnetic compatibility. With the development of power electronics technology, the power level of power conversion devices is constantly increasing, and the power current of the electric energy conversion device in the electromagnetic launch system can reach 10kA. Current probe conventionally used in EMC (electromagnetic compatibility) detection cannot meet the test requirements on high current system due to the magnetic saturation problem. The conventional high current sensor is also not suitable for the RF (Radio Frequency) interference current measurement in high current power device due to the high noise level in the output of active amplifier. In this paper, a passive flexible current probe based on Rogowski coil and matching resistance is proposed that can withstand high current and has low noise level, to solve the measurement problems of interference current in high current power converter. And both differential mode and common mode current detection can be easily carried out with the proposed probe because of the probe's flexible structure.

  7. High-voltage, high-current, solid-state closing switch

    Science.gov (United States)

    Focia, Ronald Jeffrey

    2017-08-22

    A high-voltage, high-current, solid-state closing switch uses a field-effect transistor (e.g., a MOSFET) to trigger a high-voltage stack of thyristors. The switch can have a high hold-off voltage, high current carrying capacity, and high time-rate-of-change of current, di/dt. The fast closing switch can be used in pulsed power applications.

  8. MISO Current-mode Biquad Filter with Independent Control of Pole Frequency and Quality Factor

    Directory of Open Access Journals (Sweden)

    W. Jaikla

    2012-09-01

    Full Text Available This article presents a three-inputs single-output biquadratic filter performing completely standard functions: low-pass, high-pass, band-pass, band-reject and all-pass functions, based on current controlled current conveyor transconductance amplifier (CCCCTA. The quality factor and pole frequency can be electronically/independently tuned via the input bias current. The proposed circuit uses 2 CCCCTAs and 2 grounded capacitors without external any resistors which is very suitable to further develop into an integrated circuit. The filter does not require double input current signal. Each function response can be selected by suitably selecting input signals with digital method. Moreover, the circuit possesses high output impedance which would be an ideal choice for current-mode cascading. The PSPICE simulation results are included to verify the workability of the proposed filter. The given results agree well with the theoretical anticipation.

  9. Transport and acceleration of the high-current ion beam in magneto-isolated gap

    International Nuclear Information System (INIS)

    Karas', V.I.; Kornilov, E.A.; Manuilenko, O.V.; Fedorovskaya, O.V.; Tarakanov, V.P.

    2015-01-01

    The possibility of transportation and acceleration of the high-current ion beam in the magneto-isolated gap has been demonstrated. Found the parameters of the system and beams (the magnetic field produced by the coils with opposing currents, the size of the system, and the parameters of the beams), under which the uniform acceleration of the high-current ion beam all along the gap length is realized. It is shown that the quality of the ion beam, during transport and acceleration, at the exit of the gap is acceptable for many technological applications.

  10. High-current-density electrodeposition using pulsed and constant currents to produce thick CoPt magnetic films on silicon substrates

    Science.gov (United States)

    Ewing, Jacob; Wang, Yuzheng; Arnold, David P.

    2018-05-01

    This paper investigates methods for electroplating thick (>20 μm), high-coercivity CoPt films using high current densities (up to 1 A/cm2) and elevated bath temperatures (70 °C). Correlations are made tying current-density and temperature process parameters with plating rate, elemental ratio and magnetic properties of the deposited CoPt films. It also investigates how pulsed currents can increase the plating rate and film to substrate adhesion. Using 500 mA/cm2 and constant current, high-quality, dense CoPt films were successfully electroplated up to 20 μm thick in 1 hr on silicon substrates (0.35 μm/min plating rate). After standard thermal treatment (675°C, 30 min) to achieve the ordered L10 crystalline phase, strong magnetic properties were measured: coercivities up 850 kA/m, remanences >0.5 T, and maximum energy products up to 46 kJ/m3.

  11. EXPERT-ANALITICAL MONITORING OF LEARNING PROCESS QUALITY IN HIGH SCHOOL

    Directory of Open Access Journals (Sweden)

    T. M. Korotun

    2010-10-01

    Full Text Available The technological model is proposed for monitoring process of learning process quality in high school compliant with current European and home standards. The mathematical methods are elaborated for diverse activities as to learning process objects quality determination unified support. They self-consistently combine: automatic expert evaluation with Bayesian net and Value tree models; Delphi technique enhancement; best practices for education quality assessment. Quality estimates’ consistency index is introduced for their choice and acceptability analysis. Its permanent increasing over monitoring stages is guaranteed. The tools for these stages’ automatic support are described.

  12. High current beam transport experiments at GSI

    International Nuclear Information System (INIS)

    Klabunde, J.; Schonlein, A.; Spadtke, P.

    1985-01-01

    The status of the high current ion beam transport experiment is reported. 190 keV Ar 1+ ions were injected into six periods of a magnetic quadrupole channel. Since the pulse length is > 0.5 ms partial space charge neutralization occurs. In our experiments, the behavior of unneutralized and partially space charge compensated beams is compared. With an unneutralized beam, emittance growth has been measured for high intensities even in case of the zero-current phase advance sigma 0 0 . This initial emittance growth at high tune depression we attribute to the homogenization effect of the space charge density. An analytical formula based on this assumption describes the emittance growth very well. Furthermore the predicted envelope instabilities for sigma 0 > 90 0 were observed even after 6 periods. In agreement with the theory, unstable beam transport was also experimentally found if a beam with different emittances in the two transverse phase planes was injected into the transport channel. Although the space charge force is reduced for a partially neutralized beam a deterioration of the beam quality was measured in a certain range of beam parameters. Only in the range where an unneutralized beam shows the initial emittance growth, the partial neutralization reduces this effect, otherwise the partially neutralized beam is more unstable

  13. High PRF high current switch

    Science.gov (United States)

    Moran, Stuart L.; Hutcherson, R. Kenneth

    1990-03-27

    A triggerable, high voltage, high current, spark gap switch for use in pu power systems. The device comprises a pair of electrodes in a high pressure hydrogen environment that is triggered by introducing an arc between one electrode and a trigger pin. Unusually high repetition rates may be obtained by undervolting the switch, i.e., operating the trigger at voltages much below the self-breakdown voltage of the device.

  14. Development of the High Current Ion Source for Neutral Beam Injection

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hun Ju; Kim, S. H.; Jang, D. H. [Jae Ju University, Jaeju (Korea, Republic of)

    1997-08-01

    The scope of the 1st year research is to design an 140keV deuterium ion source which has a beam current of 30-40A. According to the collected data, the model of an ion source for NBI of KSTAR was established. The negative ion source, which has good neutralization effecting in high energy, was selected. To generate a plasma, the thoriated tungsten filament was adopted. To increase the efficiency of plasma, the multi cusp type magnetic field was attached. The magnetic field was calculated by POISSON code. The extraction structure was designed with EGUN code, to extract the high quality ion beam. The design of a high current ion source for NBI was carried out. To develop the high current ion source with the high operational stability and the long lifetime, the parameters including an arc current, gas pressure and extraction voltage should be optimized. If designed ion source would be fabricated, its parameters could be optimized experimentally. Through the optimization of the ion source parameter, the core technology for NBI is established and the experiment of current drive in the fusion device can be performed. This technology also can be applied to the synthesis of new material and semiconductor industry. 18 refs., 11 tabs., 19 figs. (author)

  15. Quality of the current low power and shutdown PSA practice

    International Nuclear Information System (INIS)

    Jang, Seung Cheol; Park, Jin Hee; Lim, Ho Gon; Kim, Tae Woon

    2004-01-01

    A probabilistic safety assessment (PSA) for the low-power and shutdown (LPSD) modes in a Korea standard nuclear power plant (KSNP) has been performed for the purpose of estimating the LPSD risk and identifying the vulnerabilities of LPSD operations. Both the operational experience and PSA results indicate that the risks from LPSD operations could be comparable with those from power operations. However, the application of the LPSD risk insights to risk-informed decision making has been slow to be adopted in practice. It is largely due to the question of whether the current LPSD PSA practice is appropriate for application to risk-informed decision making or not. Such a question has to do with the quality of the current LPSD PSA practice. In this paper, we have performed self-assessment of the KSNP LPSD PSA quality based on the ANS Standard (draft as of 13 Sep. 2002). The aims of the work are to find the LPSD PSA technical areas insufficient for application to risk-informed decision making and to efficiently allocate the limited research resources to improve the LPSD PSA model quality. Many useful findings regarding the current LPSD PSA quality are presented in this paper

  16. High current plasma electron emitter

    International Nuclear Information System (INIS)

    Fiksel, G.; Almagri, A.F.; Craig, D.

    1995-07-01

    A high current plasma electron emitter based on a miniature plasma source has been developed. The emitting plasma is created by a pulsed high current gas discharge. The electron emission current is 1 kA at 300 V at the pulse duration of 10 ms. The prototype injector described in this paper will be used for a 20 kA electrostatic current injection experiment in the Madison Symmetric Torus (MST) reversed-field pinch. The source will be replicated in order to attain this total current requirement. The source has a simple design and has proven very reliable in operation. A high emission current, small size (3.7 cm in diameter), and low impurity generation make the source suitable for a variety of fusion and technological applications

  17. Next Generation High Quality Videoconferencing Service for the LHC

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    In recent times, we have witnessed an explosion of video initiatives in the industry worldwide. Several advancements in video technology are currently improving the way we interact and collaborate. These advancements are forcing tendencies and overall experiences: any device in any network can be used to collaborate, in most cases with an overall high quality. To cope with this technology progresses, CERN IT Department has taken the leading role to establish strategies and directions to improve the user experience in remote dispersed meetings and remote collaboration at large in the worldwide LHC communities. Due to the high rate of dispersion in the LHC user communities, these are critically dependent of videoconferencing technology, with a need of robustness and high quality for the best possible user experience. We will present an analysis of the factors that influenced the technical and strategic choices to improve the reliability, efficiency and overall quality of the LHC remote sessions. In particular, ...

  18. Characterisation of current and future GNSS performance in urban canyons using a high quality 3-D urban model of Melbourne, Australia

    Science.gov (United States)

    Gang-jun, Liu; Kefei, Zhang; Falin, Wu; Liam, Densley; Retscher, Günther

    2009-03-01

    Global Navigation Satellite System (GNSS) is a critical space-borne geospatial infrastructure providing essential positioning supports to a range of location-sensitive applications. GNSS is currently dominated by the US Global Positioning System (GPS) constellation. The next generation GNSS is expected to offer more satellites, better positioning provision, and improved availability and continuity of navigation support. However, GNSS performance in 3-D urban environments is problematic because GNSS signals are either completely blocked or severely degraded by high-rising geographic features like buildings. The aim of this study is to gain an in-depth understanding of the changing spatial patterns of GNSS performance, measured by the number of visible satellites (NVS) and position dilution-of-precision (PDOP), in the urban canyons of Melbourne, Australia. The methodology used includes the following steps: (1) determination of the dynamic orbital positions of current and future GNSS satellites; (2) development of a 3-D urban model of high geometric quality for Melbourne Central Business District (CBD); (3) evaluation of GNSS performance for every specified location in the urban canyons; and (4) visualisation and characterisation of the dynamic spatial patterns of GNSS performances in the urban canyons. As expected, the study shows that the integration of the GPS and Galileo constellations results in higher availability and stronger geometry, leading to significant improvement of GNSS performance in urban canyons of Melbourne CBD. Some conclusions are drawn and further research currently undertaken is also outlined.

  19. Characterization of high-current, high-temperature superconductor current lead elements

    International Nuclear Information System (INIS)

    Niemann, R.C.; Evans, D.J.; Fisher, B.L.; Brockenborough, W.E.; Roberts, P.R.; Rodenbush, A.J.

    1996-08-01

    The refrigeration loads of current leads for superconducting magnets can be significantly reduced by using high-temperature superconductor (HTS) leads. An HTS conductor type that is well suited for this application is a laminated sintered stack of HTS powder-in-tube (PIT) tapes. The superconducting elements are normally characterized by their manufacturer by measuring critical currents at 77 K in self field. Additional characterization, which correlates electrical performance at 77 K and at lower temperatures with applied magnetic fields, provides the current lead designer and conductor element manufacturer with critical information. For HTS conductor elements comprising a laminated and sintered stack of Bi-2223 PIT tapes having an alloyed Ag sheath, this characterization uses variable applied fields and operating temperatures

  20. Engineering design of a high-temperature superconductor current lead

    International Nuclear Information System (INIS)

    Niemann, R.C.; Cha, Y.S.; Hull, J.R.; Daugherty, M.A.; Buckles, W.E.

    1993-01-01

    As part of the US Department of Energy's Superconductivity Pilot Center Program, Argonne National Laboratory and Superconductivity, Inc., are developing high-temperature superconductor (HTS) current leads suitable for application to superconducting magnetic energy storage systems. The principal objective of the development program is to design, construct, and evaluate the performance of HTS current leads suitable for near-term applications. Supporting objectives are to (1) develop performance criteria; (2) develop a detailed design; (3) analyze performance; (4) gain manufacturing experience in the areas of materials and components procurement, fabrication and assembly, quality assurance, and cost; (5) measure performance of critical components and the overall assembly; (6) identify design uncertainties and develop a program for their study; and (7) develop application-acceptance criteria

  1. Engineering design of a high-temperature superconductor current lead

    Science.gov (United States)

    Niemann, R. C.; Cha, Y. S.; Hull, J. R.; Daugherty, M. A.; Buckles, W. E.

    As part of the US Department of Energy's Superconductivity Pilot Center Program, Argonne National Laboratory and Superconductivity, Inc., are developing high-temperature superconductor (HTS) current leads suitable for application to superconducting magnetic energy storage systems. The principal objective of the development program is to design, construct, and evaluate the performance of HTS current leads suitable for near-term applications. Supporting objectives are to (1) develop performance criteria; (2) develop a detailed design; (3) analyze performance; (4) gain manufacturing experience in the areas of materials and components procurement, fabrication and assembly, quality assurance, and cost; (5) measure performance of critical components and the overall assembly; (6) identify design uncertainties and develop a program for their study; and (7) develop application-acceptance criteria.

  2. Current Trends in European Quality Assurance. ENQA Workshop Report 8

    Science.gov (United States)

    Bozo, Dhurata; Damian, Radu; Gonzalez, Cecilia de la Rosa; Helle, Emmi; Imoda, Franco; Kohler, Alexander; Papazoglou, Vassilios J.; Dalmau, Gemma Rauret; Shopov, Todor

    2009-01-01

    The present report is a product of two ENQA (European Association for Quality Assurance in Higher Education) seminars, held in 2007, on current trends in European Quality Assurance. The first seminar, hosted by the Bulgarian National Evaluation and Accreditation Agency (NEAA), examined the situation in South-Eastern Europe. The second seminar…

  3. Testing of full size high current superconductors in SULTAN III

    Science.gov (United States)

    Blau, B.; Rohleder, I.; Vecsey, G.; Pasotti, G.; Ricci, M. V.; Sacchetti, N.; Bruzzone, P.; Katheder, H.; Mitchell, N.; Bessette, D.

    1994-07-01

    The high field test facility SULTAN III in operation at PSI/Switzerland tests full size industrial prototype superconductors for fusion applications such as ITER. The facility provides a background field of up to 11 T over a length of 58 cm. A 50 kA superconducting transformer works as a very low noise current source which allows a criterion of 0.1 mu V/cm to determine the superconducting to normal transition. Three 3.6 m long cable-in-conduit conductors based on both NbTi and Nb3Sn, developed by different manufacturers, suitable for the central solenoid and toroidal field coils of ITER, have been tested so far. This paper presents the results of extensive measurements of critical current and current sharing temperature of the Nb3Sn conductors in the 8 - 11 T range for temperatures between 4.5 K and 11 K. Voltage versus current curves have been analyzed with respect to the n value. The manufacturing of a high quality joint between two Nb3Sn conductors after heat treatment is reported, together with some measurements of the joint resistance.

  4. Testing of full size high current superconductors in SULTAN III

    International Nuclear Information System (INIS)

    Blau, B.; Rohleder, I.; Vecsey, G.

    1994-01-01

    The high field test facility SULTAN III in operation at PSI/Switzerland tests full size industrial prototype superconductors for fusion applications such as ITER. The facility provides a background field of up to 11 T over a length of 58 cm. A 50 kA superconducting transformer works as a very low noise current source which allows a criterion of 0.1 μV/cm to determine the superconducting to normal transition. Three 3.6 m long cable-in-conduit conductors based on both NbTi and Nb 3 Sn, developed by different manufacturers, suitable for the central solenoid and toroidal field coils of ITER, have been tested so far. This paper presents the results of extensive measurements of critical current and current sharing temperature of the Nb 3 Sn conductors in the 8--11 T range for temperatures between 4.5 K and 11 K Voltage versus current curves have been analyzed with respect to the n value. The manufacturing of a high quality joint between two Nb 3 Sn conductors after heat treatment is reported, together with some measurements of the joint resistance

  5. The Barriers to High-Quality Inpatient Pain Management: A Qualitative Study.

    Science.gov (United States)

    Lin, Richard J; Reid, M Carrington; Liu, Lydia L; Chused, Amy E; Evans, Arthur T

    2015-09-01

    The current literature suggests deficiencies in the quality of acute pain management among general medical inpatients. The aim of this qualitative study is to identify potential barriers to high-quality acute pain management among general medical inpatients at an urban academic medical center during a 2-year period. Data are collected using retrospective chart reviews, survey questionnaires, and semistructured, open-ended interviews of 40 general medical inpatients who have experienced pain during their hospitalization. Our results confirm high prevalence and disabling impacts of pain and significant patient- and provider-related barriers to high-quality acute pain management. We also identify unique system-related barriers such as time delay and pain management culture. Efforts to improve the pain management experience of general medical inpatients will need to address all these barriers. © The Author(s) 2014.

  6. Current quality criteria

    International Nuclear Information System (INIS)

    Sajaroff, Pedro M.

    1999-01-01

    The Safety Series 50-C/SG-Q 'Quality Assurance for Safety in Nuclear Power Plants and other Nuclear Installations' published by the IAEA in 1996, contains the Code and 14 Safety Guides. It is more addressed to operating organizations than to regulatory authorities. Priority is assigned to programme implementation and to work effectiveness. Emphasis is putted on doing work correctly from the very beginning (right first time attitude), and not on finding and correcting errors instead of preventing them. The essential aspects for assuring quality (that is, for achieving and maintaining an acceptable level of safety) cover the ten basic requirements established by the Code: Management (QA programme, training and qualification, non-conformance control and corrective actions, document control and records); Performance (work, design, procurement, inspection and testing for acceptance); and Assessment (management self-assessment, independent assessment). These requirements are applicable, on a graded approach basis, to the overall QA programme of the operating organization and its partial programmes during design, construction, commissioning, operation and decommissioning stages. The requirements can be also applied, with due adaptations, to other nuclear installations. The research and development activities related to such stages are comprised under the quality 'umbrella' as well. Therefore the scope of the traditional quality assurance is expanded and consolidated as a management tool more oriented to user. Responsibilities for achieving quality objectives are assigned to all involved individuals and organizations at all levels: management, working groups and assessment teams. Managers' is important but individual responsibilities are unavoidable. For the Argentine Nuclear Regulatory Authority, performance-based quality assurance was not a novelty. In line with the regulatory philosophy (which is essentially based on performance) the regulatory standard AR 3.6.1 (Rev.1

  7. Development of an IH-type linac for the acceleration of high current heavy ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Haehnel, Jan Hendrik

    2017-07-20

    The Facility for Antiproton and Ion Research (FAIR) at GSI Darmstadt will provide unprecedented intensities of protons and heavy ions up to uranium at energies of up to 29 GeV for protons and 2.7 GeV/u for U{sup 28+}. To achieve high intensities in the synchrotron accelerators, high beam currents have to be provided by the injector linear accelerators. High current heavy ion beams are provided by the Universal Linear Accelerator (UNILAC), which in its current state will not be able to provide the required FAIR beam currents. This thesis deals with the development of upgrades for the UNILAC to ensure its high current capability. The first improvement is a matching section (MEBT) for the interface between the RFQ and the IH-DTL of the existing high current injector HSI at the UNILAC. With this new MEBT section, particle losses are eliminated and the overall beam quality is improved. As a second improvement, a complete replacement of the existing Alvarez-DTL is presented. A combination of efficient IH-type cavities and KONUS beam dynamics results in a reduction of the linac length from about 60 m (Alvarez) to just 23 m (new IH-DTL) while providing the same energy and fulfilling FAIR requirements of a high beam current and beam quality. This thesis contains a detailed beam dynamics design of the new linac including some fundamental investigations of the KONUS beam dynamics concept. A cross-check of the beam dynamics design was performed with two independent multi-particle simulation codes. Detailed error studies were conducted to investigate the influence of manufacturing, alignment and operating errors on the beam dynamics performance. Additionally, all five linac cavities were designed, optimized, and their RF parameters including power requirements calculated to provide a comprehensive linac design.

  8. Development of an IH-type linac for the acceleration of high current heavy ion beams

    International Nuclear Information System (INIS)

    Haehnel, Jan Hendrik

    2017-01-01

    The Facility for Antiproton and Ion Research (FAIR) at GSI Darmstadt will provide unprecedented intensities of protons and heavy ions up to uranium at energies of up to 29 GeV for protons and 2.7 GeV/u for U 28+ . To achieve high intensities in the synchrotron accelerators, high beam currents have to be provided by the injector linear accelerators. High current heavy ion beams are provided by the Universal Linear Accelerator (UNILAC), which in its current state will not be able to provide the required FAIR beam currents. This thesis deals with the development of upgrades for the UNILAC to ensure its high current capability. The first improvement is a matching section (MEBT) for the interface between the RFQ and the IH-DTL of the existing high current injector HSI at the UNILAC. With this new MEBT section, particle losses are eliminated and the overall beam quality is improved. As a second improvement, a complete replacement of the existing Alvarez-DTL is presented. A combination of efficient IH-type cavities and KONUS beam dynamics results in a reduction of the linac length from about 60 m (Alvarez) to just 23 m (new IH-DTL) while providing the same energy and fulfilling FAIR requirements of a high beam current and beam quality. This thesis contains a detailed beam dynamics design of the new linac including some fundamental investigations of the KONUS beam dynamics concept. A cross-check of the beam dynamics design was performed with two independent multi-particle simulation codes. Detailed error studies were conducted to investigate the influence of manufacturing, alignment and operating errors on the beam dynamics performance. Additionally, all five linac cavities were designed, optimized, and their RF parameters including power requirements calculated to provide a comprehensive linac design.

  9. Audiovisual quality assessment in communications applications: Current status, trends and challenges

    DEFF Research Database (Denmark)

    Korhonen, Jari

    2010-01-01

    Audiovisual quality assessment is one of the major challenges in multimedia communications. Traditionally, algorithm-based (objective) assessment methods have focused primarily on the compression artifacts. However, compression is only one of the numerous factors influencing the perception...... addressed in practical quality metrics is the co-impact of audio and video qualities. This paper provides an overview of the current trends and challenges in objective audiovisual quality assessment, with emphasis on communication applications...

  10. Blueprint for action: steps toward a high-quality, high-value maternity care system.

    Science.gov (United States)

    Angood, Peter B; Armstrong, Elizabeth Mitchell; Ashton, Diane; Burstin, Helen; Corry, Maureen P; Delbanco, Suzanne F; Fildes, Barbara; Fox, Daniel M; Gluck, Paul A; Gullo, Sue Leavitt; Howes, Joanne; Jolivet, R Rima; Laube, Douglas W; Lynne, Donna; Main, Elliott; Markus, Anne Rossier; Mayberry, Linda; Mitchell, Lynn V; Ness, Debra L; Nuzum, Rachel; Quinlan, Jeffrey D; Sakala, Carol; Salganicoff, Alina

    2010-01-01

    Childbirth Connection hosted a 90th Anniversary national policy symposium, Transforming Maternity Care: A High Value Proposition, on April 3, 2009, in Washington, DC. Over 100 leaders from across the range of stakeholder perspectives were actively engaged in the symposium work to improve the quality and value of U.S. maternity care through broad system improvement. A multi-disciplinary symposium steering committee guided the strategy from its inception and contributed to every phase of the project. The "Blueprint for Action: Steps Toward a High Quality, High Value Maternity Care System", issued by the Transforming Maternity Care Symposium Steering Committee, answers the fundamental question, "Who needs to do what, to, for, and with whom to improve the quality of maternity care over the next five years?" Five stakeholder workgroups collaborated to propose actionable strategies in 11 critical focus areas for moving expeditiously toward the realization of the long term "2020 Vision for a High Quality, High Value Maternity Care System", also published in this issue. Following the symposium these workgroup reports and recommendations were synthesized into the current blueprint. For each critical focus area, the "Blueprint for Action" presents a brief problem statement, a set of system goals for improvement in that area, and major recommendations with proposed action steps to achieve them. This process created a clear sightline to action that if enacted could improve the structure, process, experiences of care, and outcomes of the maternity care system in ways that when anchored in the culture can indeed transform maternity care. Copyright 2010 Jacobs Institute of Women

  11. Teaching Surgical Procedures with Movies: Tips for High-quality Video Clips

    OpenAIRE

    Jacquemart, Mathieu; Bouletreau, Pierre; Breton, Pierre; Mojallal, Ali; Sigaux, Nicolas

    2016-01-01

    Summary: Video must now be considered as a precious tool for learning surgery. However, the medium does present production challenges, and currently, quality movies are not always accessible. We developed a series of 7 surgical videos and made them available on a publicly accessible internet website. Our videos have been viewed by thousands of people worldwide. High-quality educational movies must respect strategic and technical points to be reliable.

  12. Teaching Surgical Procedures with Movies: Tips for High-quality Video Clips.

    Science.gov (United States)

    Jacquemart, Mathieu; Bouletreau, Pierre; Breton, Pierre; Mojallal, Ali; Sigaux, Nicolas

    2016-09-01

    Video must now be considered as a precious tool for learning surgery. However, the medium does present production challenges, and currently, quality movies are not always accessible. We developed a series of 7 surgical videos and made them available on a publicly accessible internet website. Our videos have been viewed by thousands of people worldwide. High-quality educational movies must respect strategic and technical points to be reliable.

  13. A GPS-Based Control Framework for Accurate Current Sharing and Power Quality Improvement in Microgrids

    DEFF Research Database (Denmark)

    Golsorkhi, Mohammad; Savaghebi, Mehdi; Lu, Dylan

    2017-01-01

    This paper proposes a novel hierarchical control strategy for improvement of load sharing and power quality in ac microgrids. This control framework is composed of a droop based controller at the primary level, and a combination of distributed power sharing and voltage conditioning schemes...... consensus protocol to ensure proportional sharing of average power. The voltage conditioning scheme produces compensation signals at fundamental and dominant harmonics to improve the voltage quality at a sensitive load bus. Experimental results are presented to validate the efficacy of the proposed method....... dynamic response. The droop coefficient, which acts as a virtual resistance is adaptively changed as a function of the peak current. This strategy not only simplifies the control design but also improves the current sharing accuracy at high loading conditions. The distributed power sharing scheme uses...

  14. High Current Plasma Electrolytic Oxidation Coating Processes for Wear and Corrosion Prevention of Al 2024

    Science.gov (United States)

    Wang, Rui

    Plasma electrolytic oxidation (PEO) treatments have been used in the aerospace and automotive industries because the coating formed on light metals or alloys has great hardness, high wear, corrosion, and oxidation resistance, and a low friction coefficient that improves lifetime length and provide a higher surface quality. However, the PEO treatments that are presently used for industrial applications require a long period of time to confirm the quality of the coating. For this reason, the present study seeks to increase the current density of PEO treatments to improve their efficiency and explore the performance of the obtained coatings. It was found that for high current density (0.18A/cm2) PEO treatments, smaller ratio, such as 50% and 70%, is beneficial to obtaining a better performance coating. When compared with the coating of a "normal" (current density: 0.09A/cm2) PEO treatment, it had better wear resistance; however, for corrosion resistance, it had a lower performance than the coatings obtained by the "normal" current density PEO treatment which was attributed to the negative influence of porosity increase.

  15. Local air quality management: some evidence of current practices

    Energy Technology Data Exchange (ETDEWEB)

    Beattie, Clare; Newton, Alex; Longhurst, Jim [University of the West of England, Air Quality Research Group, Bristol (United Kingdom)

    1998-12-01

    The recent legislative changes, notably the Environment Act 1995 and resultant National Air Quality Strategy have brought new powers and obligations to local authorities to reach specified air quality standards and objectives. Initially this will involve local authorities carrying out a review and assessment of air quality in their locality by December 1999. This paper will outline a project currently being undertaken within the University of the West of England investigating how this legislation is being put into practice and present the results from a nation-wide questionnaire survey of environmental health officers. The study found that local authorities are still at an early stage of the process. It seems probable that one possible barrier to the implementation of Air Quality Management will be communication and cooperation within local authorities. (Author)

  16. Design of high current bunching system and high power fast Faraday cup for high current LEBT at VECC

    International Nuclear Information System (INIS)

    Anuraag Misra, A.; Pandit, B.V.S.; Gautam Pal, C.

    2011-01-01

    A high current microwave ion source as described is currently operational at VECC. We are able to optimize 6.4 mA of proton current in the LEBT line of ion source. The cyclotron type of accelerators accept only a fraction of DC ion beam coming from ion source so a ion beam buncher is needed to increase the accepted current into the cyclotron. The buncher described in this paper is unique in its kind as it has to handle high beam loading power upto 400 W as it is designed to bunch few mA of proton beam currents at 80 keV beam energy. A sinusoidal quarter wave RF structure has been chosen to bunch the high current beam due to high Q achievable in comparison with other configurations. This buncher has been designed using CST Microwave studio 3D advanced code since the design frequency of our buncher is 42 MHz, we have provided the RF and vacuum window near the drift tube of buncher to avoid vacuum and multipacting problems and to keep maximum volume in air region. There is a provision of multipacting interlocks to shut off amplifier during multipacting. We have carried out a detailed electromagnetic and thermal design of the buncher in CST Microwave studio and simulated values of unloaded Q was calculated be 4000. We have estimated a power of 400 W to achieve gap (designed) voltage of 10 kV. This buncher is in advanced stage of fabrication. A high power fast Faraday cup is also designed to characterize the above mentioned high current bunching system. The fast Faraday cup is designed in 50 Ω coaxial geometry to transmit fast pulse of bunched ion beam. The design of Faraday cup was completed using ANSYS HFSS and a bandwidth of 1.75 GHz was achieved this faraday cup design was different from conventional Faraday cup design as we have designed the support and cooling lines at such a place on Faraday cup which do not disturb the electrical impedance of the cup. (author)

  17. Methods and systems for fabricating high quality superconducting tapes

    Science.gov (United States)

    Majkic, Goran; Selvamanickam, Venkat

    2018-02-13

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  18. High current density ion source

    International Nuclear Information System (INIS)

    King, H.J.

    1977-01-01

    A high-current-density ion source with high total current is achieved by individually directing the beamlets from an electron bombardment ion source through screen and accelerator electrodes. The openings in these screen and accelerator electrodes are oriented and positioned to direct the individual beamlets substantially toward a focus point. 3 figures, 1 table

  19. Zerodur polishing process for high surface quality and high efficiency

    International Nuclear Information System (INIS)

    Tesar, A.; Fuchs, B.

    1992-08-01

    Zerodur is a glass-ceramic composite importance in applications where temperature instabilities influence optical and mechanical performance, such as in earthbound and spaceborne telescope mirror substrates. Polished Zerodur surfaces of high quality have been required for laser gyro mirrors. Polished surface quality of substrates affects performance of high reflection coatings. Thus, the interest in improving Zerodur polished surface quality has become more general. Beyond eliminating subsurface damage, high quality surfaces are produced by reducing the amount of hydrated material redeposited on the surface during polishing. With the proper control of polishing parameters, such surfaces exhibit roughnesses of < l Angstrom rms. Zerodur polishing was studied to recommend a high surface quality polishing process which could be easily adapted to standard planetary continuous polishing machines and spindles. This summary contains information on a polishing process developed at LLNL which reproducibly provides high quality polished Zerodur surfaces at very high polishing efficiencies

  20. High Order Voltage and Current Harmonic Mitigation Using the Modular Multilevel Converter STATCOM

    NARCIS (Netherlands)

    Kontos, E.; Tsolaridis, Georgios; Teodorescu, Remus; Bauer, P.

    2017-01-01

    Due to the increase of power electronic-based loads, the maintenance of high power quality poses a challenge in modern power systems. To limit the total harmonic distortion in the line voltage and currents at the point of the common coupling (PCC), active power filters are commonly employed. This

  1. [Quality management is associated with high quality services in health care].

    Science.gov (United States)

    Nielsen, Tenna Hassert; Riis, Allan; Mainz, Jan; Jensen, Anne-Louise Degn

    2013-12-09

    In these years, quality management has been the focus in order to meet high quality services for the patients in Danish health care. This article provides information on quality management and quality improvement and it evaluates its effectiveness in achieving better organizational structures, processes and results in Danish health-care organizations. Our findings generally support that quality management is associated with high quality services in health care.

  2. Methods and systems for fabricating high quality superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Majkic, Goran; Selvamanickam, Venkat

    2018-02-13

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  3. A Survey of Current Valued Academic Leadership Qualities in Nursing.

    Science.gov (United States)

    Delgado, Cheryl; Mitchell, Maureen M

    2016-01-01

    An informal survey was used to identify nurse faculty leadership qualities currently valued and relevant. The accelerating retirement rate for seasoned leaders has created a need for nurse educators and academic leaders. Our school was concerned that we were not meeting students' needs for today's leadership challenges. We were also interested in the experiences of leadership preparation. This was a cross-sectional, online survey of faculty at top nursing schools as determined by US News & World Report. The top leadership qualities identified were integrity, communication clarity, and problem-solving ability. Current challenges for leaders were finding qualified faculty, obtaining resources, and team building. The results may guide curricular adjustments and the transition to a new generation of nurse academic leaders.

  4. Current status of quality evaluation of nursing care through director review and reflection from the Nursing Quality Control Centers

    OpenAIRE

    Duan, Xia; Shi, Yan

    2014-01-01

    Background: The quality evaluation of nursing care is a key link in medical quality management. It is important and worth studying for the nursing supervisors to know the disadvantages during the process of quality evaluation of nursing care and then to improve the whole nursing quality. This study was to provide director insight on the current status of quality evaluation of nursing care from Nursing Quality Control Centers (NQCCs). Material and Methods: This qualitative study used a sample ...

  5. Access, Participation, and Supports: The Defining Features of High-Quality Inclusion

    Science.gov (United States)

    Buysse, Virginia

    2011-01-01

    This article describes current knowledge about early childhood inclusion, summarizing research and the DEC/NAEYC joint position statement on inclusion. The article also describes effective or promising educational practices that promote access, participation, and supports--the defining features of high-quality inclusion. Future efforts to improve…

  6. High quality electron beams from a laser wakefield accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Wiggins, S M; Issac, R C; Welsh, G H; Brunetti, E; Shanks, R P; Anania, M P; Cipiccia, S; Manahan, G G; Aniculaesei, C; Ersfeld, B; Islam, M R; Burgess, R T L; Vieux, G; Jaroszynski, D A [SUPA, Department of Physics, University of Strathclyde, Glasgow (United Kingdom); Gillespie, W A [SUPA, Division of Electronic Engineering and Physics, University of Dundee, Dundee (United Kingdom); MacLeod, A M [School of Computing and Creative Technologies, University of Abertay Dundee, Dundee (United Kingdom); Van der Geer, S B; De Loos, M J, E-mail: m.wiggins@phys.strath.ac.u [Pulsar Physics, Burghstraat 47, 5614 BC Eindhoven (Netherlands)

    2010-12-15

    High quality electron beams have been produced in a laser-plasma accelerator driven by femtosecond laser pulses with a peak power of 26 TW. Electrons are produced with an energy up to 150 MeV from the 2 mm gas jet accelerator and the measured rms relative energy spread is less than 1%. Shot-to-shot stability in the central energy is 3%. Pepper-pot measurements have shown that the normalized transverse emittance is {approx}1{pi} mm mrad while the beam charge is in the range 2-10 pC. The generation of high quality electron beams is understood from simulations accounting for beam loading of the wakefield accelerating structure. Experiments and self-consistent simulations indicate that the beam peak current is several kiloamperes. Efficient transportation of the beam through an undulator is simulated and progress is being made towards the realization of a compact, high peak brilliance free-electron laser operating in the vacuum ultraviolet and soft x-ray wavelength ranges.

  7. Development of a radio-frequency quadrupole cooler for high beam currents

    Science.gov (United States)

    Boussaid, Ramzi; Ban, G.; Quéméner, G.; Merrer, Y.; Lorry, J.

    2017-12-01

    The SHIRaC prototype is a recently developed radio-frequency quadrupole (RFQ) beam cooler with an improved optics design to deliver the required beam quality to a high resolution separator (HRS). For an isobaric separation of isotopes, the HRS demands beams with emittance not exceeding 3 π mm mrad and longitudinal energy spread ˜1 eV . Simulation studies showed a significant contribution of the buffer gas diffusion, space charge effect and mainly the rf fringe field to degrade the achieved beam quality at the RFQ exit. A miniature rf quadrupole (μ RFQ ) has been implemented at that exit to remove the degrading effects and provide beams with 1 eV of energy spread and around 1.75 π mm mrad of emittance for 4 Pa gas pressure. This solution enables also to transmit more than 60% of the incoming ions for currents up to 1 μ A . Detailed studies of this development are presented and discussed in this paper. Transport of beams from SHIRaC towards the HRS has been done with an electrostatic quadrupole triplet. Simulations and first experimental tests showed that more than 95% of ions can reach the HRS. Because SPIRAL-2 beams are of high current and very radioactive, the buffer gas will be highly contaminated. Safe maintenance of the SHIRaC beam line needs exceptional treatment of radioactive contaminants. For that, special vinyl sleep should be mounted on elements to be maintained. A detailed maintenance process will be presented.

  8. Current status of quality evaluation of nursing care through director review and reflection from the Nursing Quality Control Centers

    Science.gov (United States)

    Duan, Xia; Shi, Yan

    2014-01-01

    Background: The quality evaluation of nursing care is a key link in medical quality management. It is important and worth studying for the nursing supervisors to know the disadvantages during the process of quality evaluation of nursing care and then to improve the whole nursing quality. This study was to provide director insight on the current status of quality evaluation of nursing care from Nursing Quality Control Centers (NQCCs). Material and Methods: This qualitative study used a sample of 12 directors from NQCCs who were recruited from 12 provinces in China to evaluate the current status of quality evaluation of nursing care. Data were collected by in-depth interviews. Content analysis method was used to analyze the data. Results: Four themes emerged from the data: 1) lag of evaluation index; 2) limitations of evaluation content; 3) simplicity of evaluation method; 4) excessive emphasis on terminal quality. Conclusion: It is of great realistic significance to ameliorate nursing quality evaluation criteria, modify the evaluation content based on patient needs-oriented idea, adopt scientific evaluation method to evaluate nursing quality, and scientifically and reasonably draw horizontal comparisons of nursing quality between hospitals, as well as longitudinal comparisons of a hospital’s nursing quality. These methods mentioned above can all enhance a hospital’s core competitiveness and benefit more patients. PMID:25419427

  9. Improving sensitivity of residual current transformers to high frequency earth fault currents

    Directory of Open Access Journals (Sweden)

    Czapp Stanislaw

    2017-09-01

    Full Text Available For protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed the modification in the structure of residual current devices. This modification improves sensitivity of residual current devices when high frequency earth fault current occurs. The test of the modified residual current device proved that the authors’ proposition is appropriate.

  10. High temperature superconductor current leads

    International Nuclear Information System (INIS)

    Zeimetz, B.; Liu, H.K.; Dou, S.X.

    1996-01-01

    Full text: The use of superconductors in high electrical current applications (magnets, transformers, generators etc.) usually requires cooling with liquid Helium, which is very expensive. The superconductor itself produces no heat, and the design of Helium dewars is very advanced. Therefore most of the heat loss, i.e. Helium consumption, comes from the current lead which connects the superconductor with its power source at room temperature. The current lead usually consists of a pair of thick copper wires. The discovery of the High Temperature Superconductors makes it possible to replace a part of the copper with superconducting material. This drastically reduces the heat losses because a) the superconductor generates no resistive heat and b) it is a very poor thermal conductor compared with the copper. In this work silver-sheathed superconducting tapes are used as current lead components. The work comprises both the production of the tapes and the overall design of the leads, in order to a) maximize the current capacity ('critical current') of the superconductor, b) minimize the thermal conductivity of the silver clad, and c) optimize the cooling conditions

  11. Reducing AC-Winding Losses in High-Current High-Power Inductors

    DEFF Research Database (Denmark)

    Nymand, Morten; Madawala, Udaya K.; Andersen, Michael Andreas E.

    2009-01-01

    Foil windings are preferable in high-current high-power inductors to realize compact designs and to reduce dc-current losses. At high frequency, however, proximity effect will cause very significant increase in ac resistance in multi-layer windings, and lead to high ac winding losses. This paper ...

  12. Manufacturing of High Quality Teachers for Chemistry Education at Higher Secondary Level in Current Era

    OpenAIRE

    R. Azmat

    2013-01-01

    Education is the most influential tool whose efficient use requires the power of determination, devoted work and sacrifice. As teachers are major handler of this tool therefore, they must possess qualities of high education and competency for deliver. Education extends attractive way of life, talent and manners which make an individual a fine civilian. Primary and secondary education is one of the foundation stone of development of children and country. It acts as a vital part in placing the ...

  13. High current induction linacs

    International Nuclear Information System (INIS)

    Barletta, W.; Faltens, A.; Henestroza, E.; Lee, E.

    1994-07-01

    Induction linacs are among the most powerful accelerators in existence. They have accelerated electron bunches of several kiloamperes, and are being investigated as drivers for heavy ion driven inertial confinement fusion (HIF), which requires peak beam currents of kiloamperes and average beam powers of some tens of megawatts. The requirement for waste transmutation with an 800 MeV proton or deuteron beam with an average current of 50 mA and an average power of 40 MW lies midway between the electron machines and the heavy ion machines in overall difficulty. Much of the technology and understanding of beam physics carries over from the previous machines to the new requirements. The induction linac allows use of a very large beam aperture, which may turn out to be crucial to reducing beam loss and machine activation from the beam halo. The major issues addressed here are transport of high intensity beams, availability of sources, efficiency of acceleration, and the state of the needed technology for the waste treatment application. Because of the transformer-like action of an induction core and the accompanying magnetizing current, induction linacs make the most economic sense and have the highest efficiencies with large beam currents. Based on present understanding of beam transport limits, induction core magnetizing current requirements, and pulse modulators, the efficiencies could be very high. The study of beam transport at high intensities has been the major activity of the HIF community. Beam transport and sources are limiting at low energies but are not significant constraints at the higher energies. As will be shown, the proton beams will be space-charge-dominated, for which the emittance has only a minor effect on the overall beam diameter but does determine the density falloff at the beam edge

  14. Various categories of defects after surface alloying induced by high current pulsed electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Dian [State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001 (China); Tang, Guangze, E-mail: oaktang@hit.edu.cn [School of Material Science & Engineering, Harbin Institute of Technology, Harbin 150001 (China); Ma, Xinxin [State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001 (China); Gu, Le [School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001 (China); Sun, Mingren [School of Material Science & Engineering, Harbin Institute of Technology, Harbin 150001 (China); Wang, Liqin [School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001 (China)

    2015-10-01

    Highlights: • Four kinds of defects are found during surface alloying by high current electron beam. • Exploring the mechanism how these defects appear after irradiation. • Increasing pulsing cycles will help to get good surface quality. • Choosing proper energy density will increase surface quality. - Abstract: High current pulsed electron beam (HCPEB) is an attractive advanced materials processing method which could highly increase the mechanical properties and corrosion resistance. However, how to eliminate different kinds of defects during irradiation by HCPEB especially in condition of adding new elements is a challenging task. In the present research, the titanium and TaNb-TiW composite films was deposited on the carburizing steel (SAE9310 steel) by DC magnetron sputtering before irradiation. The process of surface alloying was induced by HCPEB with pulse duration of 2.5 μs and energy density ranging from 3 to 9 J/cm{sup 2}. Investigation of the microstructure indicated that there were several forms of defects after irradiation, such as surface unwetting, surface eruption, micro-cracks and layering. How the defects formed was explained by the results of electron microscopy and energy dispersive spectroscopy. The results also revealed that proper energy density (∼6 J/cm{sup 2}) and multi-number of irradiation (≥50 times) contributed to high quality of alloyed layers after irradiation.

  15. Properties of high current RFQ injectors

    International Nuclear Information System (INIS)

    Schempp, A.; Goethe, J.W.

    1996-01-01

    RFQ linacs are efficient, compact low energy ion structures, which have found numerous applications. They use electrical rf focusing and can capture, bunch and transmit high current ion beams. Some recent development and new projects like a heavy ion injectors for a cyclotron, and the status of the work on high current high duty factor RFQs will be discussed. (author)

  16. Properties of high current RFQ injectors

    Energy Technology Data Exchange (ETDEWEB)

    Schempp, A.; Goethe, J.W. [Frankfurt Univ. (Germany). Inst. fuer Angewandte Physik

    1996-12-31

    RFQ linacs are efficient, compact low energy ion structures, which have found numerous applications. They use electrical rf focusing and can capture, bunch and transmit high current ion beams. Some recent development and new projects like a heavy ion injectors for a cyclotron, and the status of the work on high current high duty factor RFQs will be discussed. (author) 2 refs.

  17. Total Suspended Solid (TSS Distributed by Tidal Currents during Low to High Tide Phase in the Waters of Sayung, Demak: Its Relations to Water Quality Parameters

    Directory of Open Access Journals (Sweden)

    Ulung Jantama Wisha

    2017-05-01

    Full Text Available Sayung waters is a region highly vulnerable to catastrophic erosion along the coast, which is directly followed by an increase suspended sediments and particles from the bottom of the waters that was stirred by oceanography factors. The purpose of this study was to determine the concentration and distribution of the latest TSS condition and its effect on water quality parameters in the waters of Sayung. The sampling method is using purposive sampling, with the stations spread out along the coastal area of Sayung, the main data consist of current, tide, bathymetry, coastline and water quality, and the secondary data consist of RBI map and tide forecasting, those data is analyzed numerically and statistically. TSS value ranged between 23,1-199,6 mg.L-1, the distribution of TSS is simulated in the condition of ebb to tide with current speed ranged between 0-0.41 ms-1, that distribution also influenced by physical water factors such as salinity, temperature, and density and has  impacts to enhancing the turbidity and indirectly decrease the photosynthesis activity and inhibit the oxygen cycle in the Sayung waters.

  18. Current and field distribution in high temperature superconductors

    International Nuclear Information System (INIS)

    Johnston, M.D.

    1998-01-01

    The manufacture of wires from HTS materials containing copper-oxide planes is difficult because their physical and electrical properties are highly anisotropic. The electrical connectivity depends on the nearest-neighbour grain alignment and although a high degree of grain texture is achieved through processing, the tape microstructure is generally far from uniform, with weak links and porosity also complicating the picture. In order to optimise the processing, the microstructural features common to good tapes must be identified, requiring knowledge of the local properties. The preferential path taken by transport current is determined by the properties of the local microstructure and as such can be used to measure the variation in quality across the tape cross-section. By measuring the self-field profile generated by a current-carrying tape, it is possible to extract the associated current distribution. I have designed and built a Scanning Hall Probe Microscope to measure the normal field distribution above superconductor tapes carrying DC currents, operating at liquid nitrogen temperature and zero applied magnetic field. It has a spatial resolution of 50*50 μm and a field sensitivity of 5 μT, and can scan over a distance of 6 mm. The current extraction is performed by means of a deconvolution procedure based on Legendre functions. This allows a nondestructive, non-invasive method of evaluating the effects of the processing on the tapes - especially when correlated with transport and magnetisation measurement data. Conductors fabricated from Bi 2 Sr 2 Ca 2 Cu 3 O 10 , Bi 2 Sr 2 CaCu 2 O 8 and (Tl 0.78 Bi 0.22 )(Sr 0.8 Ba 0.2 ) 2 Ca 2 Cu 3 O x , have been investigated. I have confirmed the reports that in Bi-2223/Ag mono-core conductors produced by the oxide-powder-in-tube (OPIT) technique, the current flows predominantly at the edges of the tape, where the grains are long and well-aligned. This is in contrast to Bi-2212 ribbons, where the better microstructure

  19. High current polarized electron source

    Science.gov (United States)

    Suleiman, R.; Adderley, P.; Grames, J.; Hansknecht, J.; Poelker, M.; Stutzman, M.

    2018-05-01

    Jefferson Lab operates two DC high voltage GaAs photoguns with compact inverted insulators. One photogun provides the polarized electron beam at the Continuous Electron Beam Accelerator Facility (CEBAF) up to 200 µA. The other gun is used for high average current photocathode lifetime studies at a dedicated test facility up to 4 mA of polarized beam and 10 mA of un-polarized beam. GaAs-based photoguns used at accelerators with extensive user programs must exhibit long photocathode operating lifetime. Achieving this goal represents a significant challenge for proposed facilities that must operate in excess of tens of mA of polarized average current. This contribution describes techniques to maintain good vacuum while delivering high beam currents, and techniques that minimize damage due to ion bombardment, the dominant mechanism that reduces photocathode yield. Advantages of higher DC voltage include reduced space-charge emittance growth and the potential for better photocathode lifetime. Highlights of R&D to improve the performance of polarized electron sources and prolong the lifetime of strained-superlattice GaAs are presented.

  20. Beam physics design strategy for a high-current rf linac

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M. [Univ. of Maryland, College Park, MD (United States)

    1995-10-01

    The high average beam power of an rf linac system for transmutation of nuclear waste puts very stringent requirements on beam quality and beam control. Fractional beam losses along the accelerator must be kept at extremely low levels to assure {open_quotes}hands-on{close_quotes} maintenance. Hence, halo formation and large-amplitude tails in the particle distribution due to beam mismatch and equipartitioning effects must be avoided. This implies that the beam should ideally be in near-perfect thermal equilibrium from injection to full energy - in contrast to existing rf linacs in which the transverse temperature, T {sub {perpendicular}}, is higher than the longitudinal temperature, T{sub {parallel}}. The physics and parameter scaling for such a system will be reviewed using the results of recent work on high-intensity bunched beams. A design strategy for a high-current rf linac with equilibrated beam will be proposed.

  1. High-quality compressive ghost imaging

    Science.gov (United States)

    Huang, Heyan; Zhou, Cheng; Tian, Tian; Liu, Dongqi; Song, Lijun

    2018-04-01

    We propose a high-quality compressive ghost imaging method based on projected Landweber regularization and guided filter, which effectively reduce the undersampling noise and improve the resolution. In our scheme, the original object is reconstructed by decomposing of regularization and denoising steps instead of solving a minimization problem in compressive reconstruction process. The simulation and experimental results show that our method can obtain high ghost imaging quality in terms of PSNR and visual observation.

  2. Quality Assurance Roadmap for High Performance Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    None

    2008-10-05

    This report outlines the approach to quality assurance in the construction process for new residential construction, including seven process steps from the assessment of current construction practice, through design and documentation changes, to training and quality control for on-site personnel.

  3. Fabrication of high-quality brazed joints

    International Nuclear Information System (INIS)

    Orlov, A.V.

    1980-01-01

    Problem of ensuring of joint high-quality when brazing different parts in power engineering is considered. To obtain high-quality joints it is necessary to correctly design brazed joint and to choose a gap width, overlap length and fillet radius; to clean up carefully the surfaces to be brazed and fix them properly one relative to another; to apply a solder so as to provide its flowing into the gap and sticking in it; to exactly regulate thermal conditions of brazing. High quality and reliability of brazed joints are ensured by the application of solders based on noble metals, and cheap solders based on nickel, manganese and copper. Joints brazed with nickel base solders may operate at temperatures as high as 888 deg C

  4. Soft X-ray generation via inverse compton scattering between high quality electron beam and high power laser

    International Nuclear Information System (INIS)

    Masakazu Washio; Kazuyuki Sakaue; Yoshimasa Hama; Yoshio Kamiya; Tomoko Gowa; Akihiko Masuda; Aki Murata; Ryo Moriyama; Shigeru Kashiwagi; Junji Urakawa

    2007-01-01

    High quality beam generation project based on High-Tech Research Center Project, which has been approved by Ministry of Education, Culture, Sports, Science and Technology in 1999, has been conducted by advance research institute for science and engineering, Waseda University. In the project, laser photo-cathode RF-gun has been selected for the high quality electron beam source. RF cavities with low dark current, which were made by diamond turning technique, have been successfully manufactured. The low emittance electron beam was realized by choosing the modified laser injection technique. The obtained normalized emmitance was about 3 m.mrad at 100 pC of electron charge. The soft x-ray beam generation with the energy of 370 eV, which is in the energy region of so-called water window, by inverse Compton scattering has been performed by the collision between IR laser and the low emmitance electron beams. (Author)

  5. High current and high power superconducting rectifiers

    International Nuclear Information System (INIS)

    Kate, H.H.J. ten; Bunk, P.B.; Klundert, L.J.M. van de; Britton, R.B.

    1981-01-01

    Results on three experimental superconducting rectifiers are reported. Two of them are 1 kA low frequency flux pumps, one thermally and magnetically switched. The third is a low-current high-frequency magnetically switched rectifier which can use the mains directly. (author)

  6. The ISMAR high frequency coastal radar network: Monitoring surface currents for management of marine resources

    DEFF Research Database (Denmark)

    Carlson, Daniel Frazier

    2015-01-01

    The Institute of Marine Sciences (ISMAR) of the National Research Council of Italy (CNR) established a High Frequency (HF) Coastal Radar Network for the measurement of the velocity of surface currents in coastal seas. The network consists of four HF radar systems located on the coast of the Gargano...... Promontory (Southern Adriatic, Italy). The network has been operational since May 2013 and covers an area of approximately 1700 square kilometers in the Gulf of Manfredonia. Quality Assessment (QA) procedures are applied for the systems deployment and maintenance and Quality Control (QC) procedures...

  7. A high-current, high-voltage power supply with special output current waveform for APS injector synchrotron dipole magnets

    International Nuclear Information System (INIS)

    Fathizadeh, M.; Despe, O.D.; McGhee, D.G.; Mills, F.E.; Turner, L.R.

    1991-01-01

    This paper describes a high-voltage, high-current power supply for the injector synchrotron dipole magnets at APS. In order to reset the dipole magnets in each cycle two different current waveforms are suggested. The first current waveform consists of three sections, namely: dc-reset, linear ramp, and recovery sections where injection is done ''on the fly''. The second current waveform consists of six different sections, dc-reset, transition to injection level, injection flat level, parabolic, linear ramp and recovery sections. The effect of such waveforms on the beam is discussed and the power supply limitations to follow such waveforms are given. The power supply limitations are due to the power components and control loops. The reference for the current loop is generated by a DAC which is discussed

  8. High Critical Current Coated Conductors

    Energy Technology Data Exchange (ETDEWEB)

    Paranthaman, M. P.; Selvamanickam, V. (SuperPower, Inc.)

    2011-12-27

    One of the important critical needs that came out of the DOE’s coated conductor workshop was to develop a high throughput and economic deposition process for YBCO. Metal-organic chemical vapor deposition (MOCVD) technique, the most critical steps in high technical micro fabrications, has been widely employed in semiconductor industry for various thin film growth. SuperPower has demonstrated that (Y,Gd)BCO films can be deposited rapid with world record performance. In addition to high critical current density with increased film thickness, flux pinning properties of REBCO films needs to be improved to meet the DOE requirements for various electric-power equipments. We have shown that doping with Zr can result in BZO nanocolumns, but at substantially reduced deposition rate. The primary purpose of this subtask is to develop high current density MOCVD-REBCO coated conductors based on the ion-beam assisted (IBAD)-MgO deposition process. Another purpose of this subtask is to investigate HTS conductor design optimization (maximize Je) with emphasis on stability and protection issues, and ac loss for REBCO coated conductors.

  9. High quality factor HTS Josephson junctions on low loss substrates

    Energy Technology Data Exchange (ETDEWEB)

    Stornaiuolo, D; Longobardi, L; Massarotti, D; Barone, A; Tafuri, F [CNR-SPIN Napoli, Complesso Universitario di Monte Sant' Angelo, via Cinthia, 80126 Napoli (Italy); Papari, G; Carillo, F [NEST, CNR-NANO and Scuola Normale Superiore, Piazza San Silvestro 12, 56127 Pisa (Italy); Cennamo, N [Dipartimento Ingegneria dell' Informazione, Seconda Universita degli Studi di Napoli, via Roma 29, 81031 Aversa (Italy)

    2011-04-15

    We have extended the off-axis biepitaxial technique to produce YBCO grain boundary junctions on low loss substrates. Excellent transport properties have been reproducibly found, with remarkable values of the quality factor I{sub c}R{sub n} (with I{sub c} the critical current and R{sub n} the normal state resistance) above 10 mV, far higher than the values commonly reported in the literature for high temperature superconductor (HTS) based Josephson junctions. The outcomes are consistent with a picture of a more uniform grain boundary region along the current path. This work supports a possible implementation of grain boundary junctions for various applications including terahertz sensors and HTS quantum circuits in the presence of microwaves.

  10. Providing high-quality care in primary care settings: how to make trade-offs.

    Science.gov (United States)

    Beaulieu, Marie-Dominique; Geneau, Robert; Del Grande, Claudio; Denis, Jean-Louis; Hudon, Eveline; Haggerty, Jeannie L; Bonin, Lucie; Duplain, Réjean; Goudreau, Johanne; Hogg, William

    2014-05-01

    To gain a deeper understanding of how primary care (PC) practices belonging to different models manage resources to provide high-quality care. Multiple-case study embedded in a cross-sectional study of a random sample of 37 practices. Three regions of Quebec. Health care professionals and staff of 5 PC practices. Five cases showing above-average results on quality-of-care indicators were purposefully selected to contrast on region, practice size, and PC model. Data were collected using an organizational questionnaire; the Team Climate Inventory, which was completed by health care professionals and staff; and 33 individual interviews. Detailed case histories were written and thematic analysis was performed. The core common feature of these practices was their ongoing effort to make trade-offs to deliver services that met their vision of high-quality care. These compromises involved the same 3 areas, but to varying degrees depending on clinic characteristics: developing a shared vision of high-quality care; aligning resource use with that vision; and balancing professional aspirations and population needs. The leadership of the physician lead was crucial. The external environment was perceived as a source of pressure and dilemmas rather than as a source of support in these matters. Irrespective of their models, PC practices' pursuit of high-quality care is based on a vision in which accessibility is a key component, balanced by appropriate management of available resources and of external environment expectations. Current PC reforms often create tensions rather than support PC practices in their pursuit of high-quality care. Copyright© the College of Family Physicians of Canada.

  11. Availability of high quality weather data measurements

    DEFF Research Database (Denmark)

    Andersen, Elsa; Johansen, Jakob Berg; Furbo, Simon

    In the period 2016-2017 the project “Availability of high quality weather data measurements” is carried out at Department of Civil Engineering at the Technical University of Denmark. The aim of the project is to establish measured high quality weather data which will be easily available...... for the building energy branch and the solar energy branch in their efforts to achieve energy savings and for researchers and students carrying out projects where measured high quality weather data are needed....

  12. A new high performance current transducer

    International Nuclear Information System (INIS)

    Tang Lijun; Lu Songlin; Li Deming

    2003-01-01

    A DC-100 kHz current transducer is developed using a new technique on zero-flux detecting principle. It was shown that the new current transducer is of high performance, its magnetic core need not be selected very stringently, and it is easy to manufacture

  13. Delivering high quality hip fracture rehabilitation: the perspective of occupational and physical therapy practitioners.

    Science.gov (United States)

    Leland, Natalie E; Lepore, Michael; Wong, Carin; Chang, Sun Hwa; Freeman, Lynn; Crum, Karen; Gillies, Heather; Nash, Paul

    2018-03-01

    The majority of post-acute hip fracture rehabilitation in the US is delivered in skilled nursing facilities (SNFs). Currently, there are limited guidelines that equip occupational and physical therapy practitioners with a summary of what constitutes evidence-based high quality rehabilitation. Thus, this study aimed to identify rehabilitation practitioners' perspectives on the practices that constitute high quality hip fracture rehabilitation. Focus groups were conducted with 99 occupational and physical therapy practitioners working in SNFs in southern California. Purposive sampling of facilities was conducted to capture variation in key characteristics known to impact care delivery for this patient population (e.g., financial resources, staffing, and patient case-mix). Questions aimed to elicit practitioners' perspectives on high quality hip fracture rehabilitation practices. Each session was audio-recorded and transcribed. Data were systematically analyzed using a modified grounded theory approach. Seven themes emerged: objectives of care; first 72 h; positioning, pain, and precautions; use of standardized assessments; episode of care practices; facilitating insight into progress; and interdisciplinary collaboration. Clinical guidelines are critical tools to facilitate clinical decision-making and achieve desired patient outcomes. The findings of this study highlight the practitioners' perspective on what constitutes high quality hip fracture rehabilitation. This work provides critical information to advance the development of stakeholder-driven rehabilitation clinical guidelines. Future research is needed to verify the findings from other stakeholders (e.g., patients), ensure the alignment of our findings with current evidence, and develop measures for evaluating their delivery and relationship to desired outcomes. Implications for Rehabilitation This study highlights occupational and physiotherapy therapy practitioners' perspectives on the cumulative best

  14. High quality transmission Kikuchi diffraction analysis of deformed alloys - Case study

    International Nuclear Information System (INIS)

    Tokarski, Tomasz; Cios, Grzegorz; Kula, Anna; Bała, Piotr

    2016-01-01

    Modern scanning electron microscopes (SEM) equipped with thermally assisted field emission guns (Schottky FEG) are capable of imaging with a resolution in the range of several nanometers or better. Simultaneously, the high electron beam current can be used, which enables fast chemical and crystallographic analysis with a higher resolution than is normally offered by SEM with a tungsten cathode. The current resolution that limits the EDS and EBSD analysis is related to materials' physics, particularly to the electron-specimen interaction volume. The application of thin, electron-transparent specimens, instead of bulk samples, improves the resolution and allows for the detailed analysis of very fine microstructural features. Beside the typical imaging mode, it is possible to use a standard EBSD camera in such a configuration that only transmitted and scattered electrons are detected. This modern approach was successfully applied to various materials giving rise to significant resolution improvement, especially for the light element magnesium based alloys. This paper presents an insight into the application of the transmission Kikuchi diffraction (TKD) technique applied to the most troublesome, heavily-deformed materials. In particular, the values of the highest possible acquisition rates for high resolution and high quality mapping were estimated within typical imaging conditions of stainless steel and magnesium-yttrium alloy. - Highlights: •Monte Carlo simulations were used to simulate EBSD camera intensity for various measuring conditions. •Transmission Kikuchi diffraction parameters were evaluated for highly deformed, light and heavy elements based alloys. •High quality maps with 20 nm spatial resolution were acquired for Mg and Fe based alloys. •High speed TKD measurements were performed at acquisition rates comparable to the reflection EBSD.

  15. Quench properties of high current superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Garber, M; Sampson, W B

    1980-01-01

    A technique has been developed which allows the simultaneous determination of most of the important parameters of a high current superconductor. The critical current, propagation velocity, normal state resistivity, magnetoresistance, and enthalpy are determined as a function of current and applied field. The measurements are made on non-inductive samples which simulate conditions in full scale magnets. For wide, braided conductors the propagation velocity was found to vary approximately quadratically with current in the 2 to 5 kA region. A number of conductors have been tested including some Nb/sub 3/Sn braids which have critical currents in excess of 10 kA at 5 T, 4.2 K.

  16. Wildfire Impacts Upon US Air Quality for Current and Future Climate Conditions

    Science.gov (United States)

    Gonzalez Abraham, R.; Chung, S. H.; Lamb, B. K.; Tao, I.; Avise, J. C.; Stavros, E. N.; Strand, T. T.; McKenzie, D.; Guenther, A. B.; Wiedinmyer, C.; Duhl, T.; Salathe, E. P.; Zhang, Y.

    2011-12-01

    Wildfires can have an important impact on regional air quality as they are large and intermittent sources of primary particulates, secondary aerosols, and ozone precursors. As part of an ongoing analysis on the effects of global change upon US air quality, we report results for current and future decade simulations of the inter-relationship among climate change, wildfires and air quality. The results are reported for the Northwest, Southwest, and Central Rockies regions of the US. Meteorological fields from the ECHAM5 global climate model for the IPCC A1B scenario were downscaled using the Weather Research Forecast (WRF) model to drive the MEGAN biogenic emissions model, a stochastic fire occurrence model, Fire Simulation Builder (FSB), and the CMAQ chemical transport model to predict ozone and aerosol concentrations. Simulations were completed for two nested domains covering most of the northern hemisphere from eastern Asia to North America at 220 km horizontal resolution (hemispheric domain) and covering the continental US at 36 km resolution (CONUS). Sensitivity studies were conducted for representative summer periods with fire occurrence generated from FSB within the current (1995-2004) and future decade (2045-2054) and using current decade historical fire data obtained from the Bureau of Land Management Database. Results are reported in terms of the effects of global change upon fire occurrence, fire plume transport and PM and ozone pollutant levels.

  17. High-current beam transport in electrostatic accelerator tubes

    International Nuclear Information System (INIS)

    Ramian, G.; Elais, L.

    1987-01-01

    The UCSB Free Electron Laser (FEL) has successfully demonstrated the use of a commercial 6 megavolt electrostatic accelerator as a high current beam source in a recirculating configuration. The accelerator, manufactured by National Electrostatics Corp. (NEC), Middleton WI, uses two standard high gradient accelerator tubes. Suppression of ion multiplication was accomplished by NEC with apertures and a shaped electrostatic field. This field shaping has fortuitously provided a periodically reversing radial field component with sufficient focusing strength to transport electron beams of up to 3 Amps current. Present two-stage FEL work requires a 20 Amp beam and proposed very high voltage FEL designs require currents as high as 100 Amps. A plan to permit transport of such high current beams by the addition of solenoidal focussing elements is described

  18. Formation of high-quality self-assembled monolayers of conjugated dithiols on gold: base matters.

    Science.gov (United States)

    Valkenier, Hennie; Huisman, Everardus H; van Hal, Paul A; de Leeuw, Dago M; Chiechi, Ryan C; Hummelen, Jan C

    2011-04-06

    This Article reports a systematic study on the formation of self-assembled monolayers (SAMs) of conjugated molecules for molecular electronic (ME) devices. We monitored the deprotection reaction of acetyl protected dithiols of oligophenylene ethynylenes (OPEs) in solution using two different bases and studied the quality of the resulting SAMs on gold. We found that the optimal conditions to reproducibly form dense, high-quality monolayers are 9-15% triethylamine (Et(3)N) in THF. The deprotection base tetrabutylammonium hydroxide (Bu(4)NOH) leads to less dense SAMs and the incorporation of Bu(4)N into the monolayer. Furthermore, our results show the importance of the equilibrium concentrations of (di)thiolate in solution on the quality of the SAM. To demonstrate the relevance of these results for molecular electronics applications, large-area molecular junctions were fabricated using no base, Et(3)N, and Bu(4)NOH. The magnitude of the current-densities in these devices is highly dependent on the base. A value of β=0.15 Å(-1) for the exponential decay of the current-density of OPEs of varying length formed using Et(3)N was obtained. © 2011 American Chemical Society

  19. Highly qualified does not equal high quality: A study of urban stakeholders' perceptions of quality in science teaching

    Science.gov (United States)

    Miranda, Rommel Joseph

    By employing qualitative methods, this study sought to determine the perceptions that urban stakeholders hold about what characteristics should distinguish a high school science teacher whom they would consider to demonstrate high quality in science teaching. A maximum variation sample of six science teachers, three school administrators, six parents and six students from a large urban public school district were interviewed using semi-structured, in-depth interview techniques. From these data, a list of observable characteristics which urban stakeholders hold as evidence of high quality in science teaching was generated. Observational techniques were utilized to determine the extent to which six urban high school science teachers, who meet the NCLB Act criteria for being "highly qualified", actually possessed the characteristics which these stakeholders hold as evidence of high quality in science teaching. Constant comparative analysis was used to analyze the data set. The findings suggest that urban stakeholders perceive that a high school science teacher who demonstrates high quality in science teaching should be knowledgeable about their subject matter, their student population, and should be resourceful; should possess an academic background in science and professional experience in science teaching; should exhibit professionalism, a passion for science and teaching, and a dedication to teaching and student learning; should be skillful in planning and preparing science lessons and in organizing the classroom, in presenting the subject matter to students, in conducting a variety of hands-on activities, and in managing a classroom; and should assess whether students complete class goals and objectives, and provide feedback about grades for students promptly. The findings further reveal that some of the urban high school science teachers who were deemed to be "highly qualified", as defined by the NCLB Act, engaged in practices that threatened quality in science

  20. High-current power supply for accelerator magnets

    International Nuclear Information System (INIS)

    Bourkland, K.R.; Winje, R.A.

    1978-01-01

    A power supply for controlling the current to accelerator magnets produces a high current at a precisely controlled time rate of change by varying the resonant frequency of an RLC circuit that includes the magnet and applying the current to the magnet during a predetermined portion of the waveform of an oscillation. The current is kept from going negative despite the reverse-current characteristics of thyristors by a quenching circuit

  1. Fast High-Quality Noise

    DEFF Research Database (Denmark)

    Frisvad, Jeppe Revall; Wyvill, Geoff

    2007-01-01

    At the moment the noise functions available in a graphics programmer's toolbox are either slow to compute or they involve grid-line artifacts making them of lower quality. In this paper we present a real-time noise computation with no grid-line artifacts or other regularity problems. In other words......, we put a new tool in the box that computes fast high-quality noise. In addition to being free of artifacts, the noise we present does not rely on tabulated data (everything is computed on the fly) and it is easy to adjust quality vs. quantity for the noise. The noise is based on point rendering (like...... spot noise), but it extends to more than two dimensions. The fact that it is based on point rendering makes art direction of the noise much easier....

  2. Current status of quality assurance of treatment planning systems

    International Nuclear Information System (INIS)

    Mijnheer, B.J.

    1997-01-01

    A review is given of the current status of quality assurance of treatment planning systems. At this moment only one comprehensive report is available. In order to review national activities a questionnaire has been distributed amongst national societies of medical physicists. From the 23 responding countries, 8 indicated that only limited efforts are underway, 8 answered that a working group is evaluating their specific national requirements while in 5 countries a document is drafted. The highlights of these reports have been summarized. (author)

  3. High-κ gate dielectrics: Current status and materials properties considerations

    Science.gov (United States)

    Wilk, G. D.; Wallace, R. M.; Anthony, J. M.

    2001-05-01

    Many materials systems are currently under consideration as potential replacements for SiO2 as the gate dielectric material for sub-0.1 μm complementary metal-oxide-semiconductor (CMOS) technology. A systematic consideration of the required properties of gate dielectrics indicates that the key guidelines for selecting an alternative gate dielectric are (a) permittivity, band gap, and band alignment to silicon, (b) thermodynamic stability, (c) film morphology, (d) interface quality, (e) compatibility with the current or expected materials to be used in processing for CMOS devices, (f) process compatibility, and (g) reliability. Many dielectrics appear favorable in some of these areas, but very few materials are promising with respect to all of these guidelines. A review of current work and literature in the area of alternate gate dielectrics is given. Based on reported results and fundamental considerations, the pseudobinary materials systems offer large flexibility and show the most promise toward successful integration into the expected processing conditions for future CMOS technologies, especially due to their tendency to form at interfaces with Si (e.g. silicates). These pseudobinary systems also thereby enable the use of other high-κ materials by serving as an interfacial high-κ layer. While work is ongoing, much research is still required, as it is clear that any material which is to replace SiO2 as the gate dielectric faces a formidable challenge. The requirements for process integration compatibility are remarkably demanding, and any serious candidates will emerge only through continued, intensive investigation.

  4. Current Quality-of-Life Tools Available for Use in Contact Dermatitis.

    Science.gov (United States)

    Swietlik, Jacquelyn; Reeder, Margo

    2016-01-01

    Contact dermatitis is a common dermatologic condition that can cause significant impairment in patients' overall quality of life (QoL). This impact is separate and potentially more clinically relevant than one's disease "severity" in contact dermatitis and should be consistently addressed by dermatologists. Despite this, QoL tools specific to contact dermatitis are lacking, and there is little consistency in the literature regarding the tool used to evaluate clinical response to therapies. Measurements currently available to evaluate disease-related QoL in contact dermatitis fit into 1 of the following 3 general types: generic health-related QoL measures, dermatology-related QoL measures, or specific dermatologic disease-related QoL measures. This article reviews the strengths and weaknesses of existing QoL tools used in contact dermatitis including: Short Form Survey 36, Dermatology Life Quality Index, Skindex-29, Skindex-16, Dermatology-Specific Quality of Life, and Fragrance Quality of Life Index.

  5. Assuring quality in high-consequence engineering

    Energy Technology Data Exchange (ETDEWEB)

    Hoover, Marcey L.; Kolb, Rachel R.

    2014-03-01

    In high-consequence engineering organizations, such as Sandia, quality assurance may be heavily dependent on staff competency. Competency-dependent quality assurance models are at risk when the environment changes, as it has with increasing attrition rates, budget and schedule cuts, and competing program priorities. Risks in Sandia's competency-dependent culture can be mitigated through changes to hiring, training, and customer engagement approaches to manage people, partners, and products. Sandia's technical quality engineering organization has been able to mitigate corporate-level risks by driving changes that benefit all departments, and in doing so has assured Sandia's commitment to excellence in high-consequence engineering and national service.

  6. Internet of Things: Current Challenges in the Quality Assurance and Testing Methods

    OpenAIRE

    Bures, Miroslav; Cerny, Tomas; Ahmed, Bestoun S.

    2018-01-01

    Contemporary development of the Internet of Things (IoT) technology brings a number of challenges in the Quality Assurance area. Current issues related to security, user's privacy, the reliability of the service, interoperability, and integration are discussed. All these create a demand for specific Quality Assurance methodology for the IoT solutions. In the paper, we present the state of the art of this domain and we discuss particular areas of system testing discipline, which is not covered...

  7. Methods for slow axis beam quality improvement of high power broad area diode lasers

    Science.gov (United States)

    An, Haiyan; Xiong, Yihan; Jiang, Ching-Long J.; Schmidt, Berthold; Treusch, Georg

    2014-03-01

    For high brightness direct diode laser systems, it is of fundamental importance to improve the slow axis beam quality of the incorporated laser diodes regardless what beam combining technology is applied. To further advance our products in terms of increased brightness at a high power level, we must optimize the slow axis beam quality despite the far field blooming at high current levels. The later is caused predominantly by the built-in index step in combination with the thermal lens effect. Most of the methods for beam quality improvements reported in publications sacrifice the device efficiency and reliable output power. In order to improve the beam quality as well as maintain the efficiency and reliable output power, we investigated methods of influencing local heat generation to reduce the thermal gradient across the slow axis direction, optimizing the built-in index step and discriminating high order modes. Based on our findings, we have combined different methods in our new device design. Subsequently, the beam parameter product (BPP) of a 10% fill factor bar has improved by approximately 30% at 7 W/emitter without efficiency penalty. This technology has enabled fiber coupled high brightness multi-kilowatt direct diode laser systems. In this paper, we will elaborate on the methods used as well as the results achieved.

  8. A high throughput DNA extraction method with high yield and quality

    Directory of Open Access Journals (Sweden)

    Xin Zhanguo

    2012-07-01

    Full Text Available Abstract Background Preparation of large quantity and high quality genomic DNA from a large number of plant samples is a major bottleneck for most genetic and genomic analyses, such as, genetic mapping, TILLING (Targeting Induced Local Lesion IN Genome, and next-generation sequencing directly from sheared genomic DNA. A variety of DNA preparation methods and commercial kits are available. However, they are either low throughput, low yield, or costly. Here, we describe a method for high throughput genomic DNA isolation from sorghum [Sorghum bicolor (L. Moench] leaves and dry seeds with high yield, high quality, and affordable cost. Results We developed a high throughput DNA isolation method by combining a high yield CTAB extraction method with an improved cleanup procedure based on MagAttract kit. The method yielded large quantity and high quality DNA from both lyophilized sorghum leaves and dry seeds. The DNA yield was improved by nearly 30 fold with 4 times less consumption of MagAttract beads. The method can also be used in other plant species, including cotton leaves and pine needles. Conclusion A high throughput system for DNA extraction from sorghum leaves and seeds was developed and validated. The main advantages of the method are low cost, high yield, high quality, and high throughput. One person can process two 96-well plates in a working day at a cost of $0.10 per sample of magnetic beads plus other consumables that other methods will also need.

  9. Optimization of Superconducting Focusing Quadrupoles for the HighCurrent Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Sabbi, GianLuca; Gourlay, Steve; Gung, Chen-yu; Hafalia, Ray; Lietzke, Alan; Martovetski, Nicolai; Mattafirri, Sara; Meinke, Rainer; Minervini, Joseph; Schultz, Joel; Seidl, Peter

    2005-09-16

    The Heavy Ion Fusion (HIF) program is progressing through a series of physics and technology demonstrations leading to an inertial fusion power plant. The High Current Experiment (HCX) at Lawrence Berkeley National Laboratory is exploring the physics of intense beams with high line-charge density. Superconducting focusing quadrupoles have been developed for the HCX magnetic transport studies. A baseline design was selected following several pre-series models. Optimization of the baseline design led to the development of a first prototype that achieved a conductor-limited gradient of 132 T/m in a 70 mm bore, without training, with measured field errors at the 0.1% level. Based on these results, the magnet geometry and fabrication procedures were adjusted to improve the field quality. These modifications were implemented in a second prototype. In this paper, the optimized design is presented and comparisons between the design harmonics and magnetic measurements performed on the new prototype are discussed.

  10. High current vacuum closing switch

    International Nuclear Information System (INIS)

    Dolgachev, G.I.; Maslennikov, D.D.; Romanov, A.S.; Ushakov, A.G.

    2005-01-01

    The paper proposes a powerful pulsed closing vacuum switch for high current commutation consisting of series of the vacuum diodes with near 1 mm gaps having closing time determined by the gaps shortening with the near-electrode plasmas [ru

  11. Studies on the current state of water quality in the Segamat River

    Science.gov (United States)

    Razelan, Faridah Mohd; Tahir, Wardah; E. M Yahaya, Nasehir Khan

    2018-04-01

    Nowadays, pollution has become a major concern in developed and developing countries. In a study on the current state of Segamat River water quality; on-site data collection and observation and also laboratory data analysis have been implemented. Studies showed that the downstream of the Segamat River has recorded a significant reduction in quality of water during the dry season compared to the wet season. The deterioration of water quality is caused by the activities along the river such as palm oil plantation, municipal waste and waste from settlements. It was also recorded that the point sources were dominating the pollution at Segamat River during the dry season. However, during the wet season, the water quality was impaired by the non-point sources which originated from the upstream of the river.

  12. High current density ion beam measurement techniques

    International Nuclear Information System (INIS)

    Ko, W.C.; Sawatzky, E.

    1976-01-01

    High ion beam current measurements are difficult due to the presence of the secondary particles and beam neutralization. For long Faraday cages, true current can be obtained only by negative bias on the target and by summing the cage wall and target currents; otherwise, the beam will be greatly distorted. For short Faraday cages, a combination of small magnetic field and the negative target bias results in correct beam current. Either component alone does not give true current

  13. A Narrative Review of High-Quality Literature on the Effects of Resident Duty Hours Reforms.

    Science.gov (United States)

    Lin, Henry; Lin, Emery; Auditore, Stephanie; Fanning, Jon

    2016-01-01

    To summarize current high-quality studies evaluating the effect and efficacy of resident duty hours reforms (DHRs) on patient safety and resident education and well-being. The authors searched PubMed and Medline in August 2012 and again in May 2013 for literature (1987-2013) about the effects of DHRs. They assessed the quality of articles using the Medical Education Research Study Quality Instrument (MERSQI) scoring system. They considered randomized controlled trials (RCTs), partial RCTs, and all studies with a MERSQI score ≥ 14 to be "high-quality" methodology studies. A total of 72 high-quality studies met inclusion criteria. Most studies showed no change or slight improvement in mortality and complication rates after DHRs. Resident well-being was generally improved, but there was a perceived negative impact on education (knowledge acquisition, skills, and cognitive performance) following DHRs. Eleven high-quality studies assessed the impact of DHR interventions; all reported a neutral to positive impact. Seven high-quality studies assessed costs associated with DHRs and demonstrated an increase in hospital costs. The results of most studies that allow enough time for DHR interventions to take effect suggest a benefit to patient safety and resident well-being, but the effect on the quality of training remains unknown. Additional methodologically sound studies on the impact of DHRs are necessary. Priorities for future research include approaches to optimizing education and clinical proficiency and studies on the effect of intervention strategies on both education and patient safety. Such studies will provide additional information to help improve duty hours policies.

  14. Concrete Waste Recycling Process for High Quality Aggregate

    International Nuclear Information System (INIS)

    Ishikura, Takeshi; Fujii, Shin-ichi

    2008-01-01

    Large amount of concrete waste generates during nuclear power plant (NPP) dismantling. Non-contaminated concrete waste is assumed to be disposed in a landfill site, but that will not be the solution especially in the future, because of decreasing tendency of the site availability and natural resources. Concerning concrete recycling, demand for roadbeds and backfill tends to be less than the amount of dismantled concrete generated in a single rural site, and conventional recycled aggregate is limited of its use to non-structural concrete, because of its inferior quality to ordinary natural aggregate. Therefore, it is vital to develop high quality recycled aggregate for general uses of dismantled concrete. If recycled aggregate is available for high structural concrete, the dismantling concrete is recyclable as aggregate for industry including nuclear field. Authors developed techniques on high quality aggregate reclamation for large amount of concrete generated during NPP decommissioning. Concrete of NPP buildings has good features for recycling aggregate; large quantity of high quality aggregate from same origin, record keeping of the aggregate origin, and little impurities in dismantled concrete such as wood and plastics. The target of recycled aggregate in this development is to meet the quality criteria for NPP concrete as prescribed in JASS 5N 'Specification for Nuclear Power Facility Reinforced Concrete' and JASS 5 'Specification for Reinforced Concrete Work'. The target of recycled aggregate concrete is to be comparable performance with ordinary aggregate concrete. The high quality recycled aggregate production techniques are assumed to apply for recycling for large amount of non-contaminated concrete. These techniques can also be applied for slightly contaminated concrete dismantled from radiological control area (RCA), together with free release survey. In conclusion: a technology on dismantled concrete recycling for high quality aggregate was developed

  15. Survey of Current Status of Quality Control of Gamma Cameras in Republic of Korea

    International Nuclear Information System (INIS)

    Choe, Jae Gol; Joh, Cheol Woo

    2008-01-01

    It is widely recognized that good quality control (QC) program is essential for adequate imaging diagnosis using gamma camera. The purpose of this study is to survey the current status of QC of gamma cameras in Republic of Korea for implementing appropriate nationwide quality control guidelines and programs. A collection of data is done for personnel, equipment and appropriateness of each nuclear medicine imaging laboratory's' quality control practice. This survey is done by collection of formatted questionnaire by mails, e mails or interviews. We also reviewed the current recommendations concerning quality assurance by international societies. This survey revealed that practice of quality control is irregular and not satisfactory. The irregularity of the QC practice seems due partly to the lack of trained personnel, equipment, budget, time and hand-on guidelines. The implementation of QC program may cause additional burden to the hospitals, patients and nuclear medicine laboratories. However, the benefit of a good QC program is obvious that the hospitals can provide good quality nuclear medicine imaging studies to the patients. It is important to use least cumbersome QC protocol, to educate the nuclear medicine and hospital administrative personnel concerning QC, and to establish national QC guidelines to help each individual nuclear medicine laboratory

  16. Quality and efficiency in high dimensional Nearest neighbor search

    KAUST Repository

    Tao, Yufei; Yi, Ke; Sheng, Cheng; Kalnis, Panos

    2009-01-01

    Nearest neighbor (NN) search in high dimensional space is an important problem in many applications. Ideally, a practical solution (i) should be implementable in a relational database, and (ii) its query cost should grow sub-linearly with the dataset size, regardless of the data and query distributions. Despite the bulk of NN literature, no solution fulfills both requirements, except locality sensitive hashing (LSH). The existing LSH implementations are either rigorous or adhoc. Rigorous-LSH ensures good quality of query results, but requires expensive space and query cost. Although adhoc-LSH is more efficient, it abandons quality control, i.e., the neighbor it outputs can be arbitrarily bad. As a result, currently no method is able to ensure both quality and efficiency simultaneously in practice. Motivated by this, we propose a new access method called the locality sensitive B-tree (LSB-tree) that enables fast highdimensional NN search with excellent quality. The combination of several LSB-trees leads to a structure called the LSB-forest that ensures the same result quality as rigorous-LSH, but reduces its space and query cost dramatically. The LSB-forest also outperforms adhoc-LSH, even though the latter has no quality guarantee. Besides its appealing theoretical properties, the LSB-tree itself also serves as an effective index that consumes linear space, and supports efficient updates. Our extensive experiments confirm that the LSB-tree is faster than (i) the state of the art of exact NN search by two orders of magnitude, and (ii) the best (linear-space) method of approximate retrieval by an order of magnitude, and at the same time, returns neighbors with much better quality. © 2009 ACM.

  17. High field, low current operation of engineering test reactors

    International Nuclear Information System (INIS)

    Schwartz, J.; Cohn, D.R.; Bromberg, L.; Williams, J.E.C.

    1987-06-01

    Steady state engineering test reactors with high field, low current operation are investigated and compared to high current, lower field concepts. Illustrative high field ETR parameters are R = 3 m, α ∼ 0.5 m, B ∼ 10 T, β = 2.2% and I = 4 MA. For similar wall loading the fusion power of an illustrative high field, low current concept could be about 50% that of a lower field device like TIBER II. This reduction could lead to a 50% decrease in tritium consumption, resulting in a substantial decrease in operating cost. Furthermore, high field operation could lead to substantially reduced current drive requirements and cost. A reduction in current drive source power on the order of 40 to 50 MW may be attainable relative to a lower field, high current design like TIBER II implying a possible cost savings on the order of $200 M. If current drive is less efficient than assumed, the savings could be even greater. Through larger β/sub p/ and aspect ratio, greater prospects for bootstrap current operation also exist. Further savings would be obtained from the reduced size of the first wall/blanket/shield system. The effects of high fields on magnet costs are very dependent on technological assumptions. Further improvements in the future may lie with advances in superconducting and structural materials

  18. Highly efficient red electrophosphorescent devices at high current densities

    International Nuclear Information System (INIS)

    Wu Youzhi; Zhu Wenqing; Zheng Xinyou; Sun, Runguang; Jiang Xueyin; Zhang Zhilin; Xu Shaohong

    2007-01-01

    Efficiency decrease at high current densities in red electrophosphorescent devices is drastically restrained compared with that from conventional electrophosphorescent devices by using bis(2-methyl-8-quinolinato)4-phenylphenolate aluminum (BAlq) as a hole and exciton blocker. Ir complex, bis(2-(2'-benzo[4,5-α]thienyl) pyridinato-N,C 3' ) iridium (acetyl-acetonate) is used as an emitter, maximum external quantum efficiency (QE) of 7.0% and luminance of 10000cd/m 2 are obtained. The QE is still as high as 4.1% at higher current density J=100mA/cm 2 . CIE-1931 co-ordinates are 0.672, 0.321. A carrier trapping mechanism is revealed to dominate in the process of electroluminescence

  19. Measurement-based harmonic current modeling of mobile storage for power quality study in the distribution system

    Directory of Open Access Journals (Sweden)

    Wenge Christoph

    2017-12-01

    Full Text Available Electric vehicles (EVs can be utilized as mobile storages in a power system. The use of battery chargers can cause current harmonics in the supplied AC system. In order to analyze the impact of different EVs with regardto their number and their emission of current harmonics, a generic harmonic current model of EV types was built and implemented in the power system simulation tool PSS®NETOMAC. Based on the measurement data for different types of EVs three standardized harmonic EV models were developed and parametrized. Further, the identified harmonic models are used by the computation of load flow in a modeled, German power distribution system. As a benchmark, a case scenario was studied regarding a high market penetration of EVs in the year 2030 for Germany. The impact of the EV charging on the power distribution system was analyzed and evaluated with valid power quality standards.

  20. The use of citation indicators to identify and support high-quality research in Poland.

    Science.gov (United States)

    Pilc, Andrzej

    2008-01-01

    In large, mostly English-speaking countries, where the "critical mass" of scientists working in different subfields of science is achieved, the peer review system may be sufficient to assess the quality of scientific research. However, in smaller countries, outside the Anglo-American circle, it is important to introduce different systems to identify research of high quality. In Poland, a parametric system for assessing the quality of research has been introduced. It was largely based on the impact factor of scientific journals. While the use of this indicator to assess research quality is highly questionable, the implementation of the system in the Polish reality is even worse. Therefore it is important to change and improve the system currently used by the Ministry of Science and Higher Education to both evaluate and, more importantly, finance science in Poland. Here, a system based on three factors, i.e. the impact factor, the institutional h-index, and the institutional number of citations, is proposed. The scientific quality of institutions in Division VI: Medical Sciences of the Polish Academy of Sciences were evaluated and the results were compared with the existing system. Moreover, a method to identify high-quality researchers and institutions at the national level based on the quantity of highly cited papers is shown. Additionally, an attempt to identify the highest quality Polish research on an international level is proposed. This is based on the number of individual citations, the individual h-index, the number of publications, and the priority of the discovery.

  1. Impacts of current and projected oil palm plantation expansion on air quality over Southeast Asia

    Directory of Open Access Journals (Sweden)

    S. J. Silva

    2016-08-01

    Full Text Available Over recent decades oil palm plantations have rapidly expanded across Southeast Asia (SEA. According to the United Nations, oil palm production in SEA increased by a factor of 3 from 1995 to 2010. We investigate the impacts of current (2010 and near-term future (2020 projected oil palm expansion in SEA on surface–atmosphere exchange and the resulting air quality in the region. For this purpose, we use satellite data, high-resolution land maps, and the chemical transport model GEOS-Chem. Relative to a no oil palm plantation scenario (∼ 1990, overall simulated isoprene emissions in the region increased by 13 % due to oil palm plantations in 2010 and a further 11 % in the near-term future. In addition, the expansion of palm plantations leads to local increases in ozone deposition velocities of up to 20 %. The net result of these changes is that oil palm expansion in SEA increases surface O3 by up to 3.5 ppbv over dense urban regions, and in the near-term future could rise more than 4.5 ppbv above baseline levels. Biogenic secondary organic aerosol loadings also increase by up to 1 µg m−3 due to oil palm expansion, and could increase by a further 2.5 µg m−3 in the near-term future. Our analysis indicates that while the impact of recent oil palm expansion on air quality in the region has been significant, the retrieval error and sensitivity of the current constellation of satellite measurements limit our ability to observe these impacts from space. Oil palm expansion is likely to continue to degrade air quality in the region in the coming decade and hinder efforts to achieve air quality regulations in major urban areas such as Kuala Lumpur and Singapore.

  2. Simple, high current, antimony ion source

    International Nuclear Information System (INIS)

    Sugiura, H.

    1979-01-01

    A simple metal ion source capable of producing a continuous, uncontaminated, high current beam of Sb ions is presented. It produced a total ion current of 200 μA at 1 kV extraction voltage. A discharge occurred in the source at a pressure of 6 x 10 -4 Torr. The ion current extracted from the source increased with the 3/2 power of the extraction voltage. The perveance of the source and ion density in the plasma were 8 x 10 -9 and 1.8 x 10 11 cm -3 , respectively

  3. Effect of forage quality in faeces from different ruminant species fed high and low quality forage

    DEFF Research Database (Denmark)

    Jalali, A R; Nørgaard, P; Nielsen, M O

    2010-01-01

    Effect of forage quality in faeces from different ruminant species fed high and low quality forage......Effect of forage quality in faeces from different ruminant species fed high and low quality forage...

  4. High-current discharge channel contraction in high density gas

    International Nuclear Information System (INIS)

    Rutberg, Ph. G.; Bogomaz, A. A.; Pinchuk, M. E.; Budin, A. V.; Leks, A. G.; Pozubenkov, A. A.

    2011-01-01

    Research results for discharges at current amplitudes of 0.5-1.6 MA and current rise rate of ∼10 10 A/s are presented. The discharge is performed in the hydrogen environment at the initial pressure of 5-35 MPa. Initiation is implemented by a wire explosion. The time length of the first half-period of the discharge current is 70-150 μs. Under such conditions, discharge channel contraction is observed; the contraction is followed by soft x-ray radiation. The phenomena are discussed, which are determined by high density of the gas surrounding the discharge channel. These phenomena are increase of the current critical value, where the channel contraction begins and growth of temperature in the axis region of the channel, where the initial density of the gas increases.

  5. Minimizing quality changes of cloudy apple juice: The use of kiwifruit puree and high pressure homogenization.

    Science.gov (United States)

    Yi, Junjie; Kebede, Biniam; Kristiani, Kristiani; Grauwet, Tara; Van Loey, Ann; Hendrickx, Marc

    2018-05-30

    Cloud loss, enzymatic browning, and flavor changes are important quality defects of cloudy fruit juices determining consumer acceptability. The development of clean label options to overcome such quality problems is currently of high interest. Therefore, this study investigated the effect of kiwifruit puree (clean label ingredient) and high pressure homogenization on quality changes of cloudy apple juice using a multivariate approach. The use of kiwifruit puree addition and high pressure homogenization resulted in a juice with improved uniformity and cloud stability by reducing particle size and increasing viscosity and yield stress (p < 0.01). Furthermore, kiwifruit puree addition reduced enzymatic browning (ΔE ∗  < 3), due to the increased ascorbic acid and contributed to a more saturated and bright yellow color, a better taste balance, and a more fruity aroma of juice. This work demonstrates that clean label options to control quality degradation of cloudy fruit juice might offer new opportunities. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. TOTAL QUALITY MANAGEMENT IN HIGH EDUCATION

    Directory of Open Access Journals (Sweden)

    Hasan SERİN, Alper AYTEKİN

    2009-01-01

    Full Text Available The approach of Total Quality Management (TQM has been even more common and most recently its use in high education has been discussed. Likewise the enterprises producing various products, universities have also inputs, processes, and outputs. Due to conditions of competition, universities have to improve the qualities of these inputs, processes, and outputs, according to satisfaction, demands, and expectations of internal and external customers. If the TQM has been implemented in the universities with a manner that aims for customer satisfaction (students, lecturers, public and private establishments, and families, supports constant development, ensures participatory approach, and encourages working in groups, it will provide universities with effectiveness, efficiency, dynamics, and economics. In this study, common problems of universities, definitions of quality and TQM in high education, customer concept at universities, and factors affecting the quality of education have been explained. Besides, in order TQM approach to be successfully implemented in the universities, various suggestions have been presented.

  7. Supercapacitors based on high-quality graphene scrolls

    Science.gov (United States)

    Zeng, Fanyan; Kuang, Yafei; Liu, Gaoqin; Liu, Rui; Huang, Zhongyuan; Fu, Chaopeng; Zhou, Haihui

    2012-06-01

    High-quality graphene scrolls (GSS) with a unique scrolled topography are designed using a microexplosion method. Their capacitance properties are investigated by cyclic voltammetry, galvanostatic charge-discharge and electrical impedance spectroscopy. Compared with the specific capacity of 110 F g-1 for graphene sheets, a remarkable capacity of 162.2 F g-1 is obtained at the current density of 1.0 A g-1 in 6 M KOH aqueous solution owing to the unique scrolled structure of GSS. The capacity value is increased by about 50% only because of the topological change of graphene sheets. Meanwhile, GSS exhibit excellent long-term cycling stability along with 96.8% retained after 1000 cycles at 1.0 A g-1. These encouraging results indicate that GSS based on the topological structure of graphene sheets are a kind of promising material for supercapacitors.

  8. Current status of postnatal depression smartphone applications available on application stores: an information quality analysis.

    Science.gov (United States)

    Zhang, Melvyn Wb; Ho, Roger Cm; Loh, Alvona; Wing, Tracey; Wynne, Olivia; Chan, Sally Wai Chi; Car, Josip; Fung, Daniel Shuen Sheng

    2017-11-14

    It is the aim of the current research to identify some common functionalities of postnatal application, and to determine the quality of the information content of postnatal depression application using validated scales that have been applied for applications in other specialties. To determine the information quality of the postnatal depression smartphone applications, the two most widely used smartphone application stores, namely Apple iTunes as well as Google Android Play store, were searched between 20May and 31 May. No participants were involved. The inclusion criteria for the application were that it must have been searchable using the keywords 'postnatal', 'pregnancy', 'perinatal', 'postpartum' and 'depression', and must be in English language. The Silberg Scale was used in the assessment of the information quality of the smartphone applications. The information quality score was the primary outcome measure. Our current results highlighted that while there is currently a myriad of applications, only 14 applications are specifically focused on postnatal depression. In addition, the majority of the currently available applications on the store have only disclosed their last date of modification as well as ownership. There remain very limited disclosures about the information of the authors, as well as the references for the information included in the application itself. The average score for the Silberg Scale for the postnatal applications we have analysed is 3.0. There remains a need for healthcare professionals and developers to jointly conceptualise new applications with better information quality and evidence base. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Current conceptions of industrial quality assurance

    International Nuclear Information System (INIS)

    Zeller, H.

    1978-01-01

    In the electrical engineering industry quality assurance is mainly oriented in accordance with the customers', users', and consumers' requirements concerning the quality of products (including reliability). These requirements are as manifold as the range of products itself. They do not only comprise functional criteria, but also safety against malfunctions, bodily injury or property damage. Quality assurance is embedded in the overall activities of a company; the peripheral conditions, such as organization, profitability, qualification, and responsibility of staff have to be considered. Thus, quality assurance in the electrical engineering industry proceeds in efficient systems which are adapted to the individual forms of production. These systems may include planning, testing, feedback of quality data, statistical procedures, costs and profitability. Their obvious interaction is based on the system of coordinates of integrated quality control. The paper will illustrate the basic features of this interaction by reference to various examples. (orig.) [de

  10. Analysis of high-quality modes in open chaotic microcavities

    International Nuclear Information System (INIS)

    Fang, W.; Yamilov, A.; Cao, H.

    2005-01-01

    We present a numerical study of the high-quality modes in two-dimensional dielectric stadium microcavities. Although the classical ray mechanics is fully chaotic in a stadium billiard, all of the high-quality modes show a 'strong scar' around unstable periodic orbits. When the deformation (ratio of the length of the straight segments over the diameter of the half circles) is small, the high-quality modes correspond to whispering-gallery-type trajectories and their quality factors decrease monotonically with increasing deformation. At large deformation, each high-quality mode is associated with multiple unstable periodic orbits. Its quality factor changes nonmonotonically with the deformation, and there exists an optimal deformation for each mode at which its quality factor reaches a local maximum. This unusual behavior is attributed to the interference of waves propagating along different constituent orbits that could minimize light leakage out of the cavity

  11. Compact high-current, subnanosecond electron accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Shpak, V G; Shunajlov, S A; Ulmaskulov, M R; Yalandin, M I [Russian Academy of Sciences, Ekaterinburg (Russian Federation). Inst. of Electrophysics; Pegel, I V [Russian Academy of Sciences, Tomsk (Russian Federation). High-Current Electronics Inst.; Tarakanov, V P [Russian Academy of Sciences, Moscow (Russian Federation). High-Temperature Inst.

    1997-12-31

    A compact subnanosecond, high-current electron accelerator producing an annular electron beam of duration up to 300 - 400 ps, energy about 250 keV, and current up to 1 kA has been developed to study transient processes in pulsed power microwave devices. The measuring and recording techniques used to experimentally investigate the dynamics of the beam current pulse and the transformation of the electron energy during the transportation of the beam in a longitudinal magnetic field are described. The experimental data obtained are compared with the predictions of a numerical simulation. (author). 6 figs., 5 refs.

  12. Development of a high current ion implanter

    International Nuclear Information System (INIS)

    Choi, Byung Ho; Kim, Wan; Jin, Jeong Tae

    1990-01-01

    A high current ion implanter of the energy of 100 Kev and the current of about 100 mA has been developed for using the high dose ion implantation, surface modification of steels and ceramics, and ion beam milling. The characteristics of the beam extraction and transportation are investigated. A duoPIGatron ion source compatible with gas ion extraction of about 100 mA, a single gap acceleration tube which is able to compensate the divergence due to the space charge effect, and a beam transport system with the concept of the space charge neutralization are developed for the high current machine. The performance of the constructed machine shows that nitrogen, argon, helium, hydrogen and oxygen ion beams are successfully extracted and transported at a beam divergence due to space charge effect is negligible in the operation pressure of 2 x 10 -5 torr. (author)

  13. Stable superconducting magnet. [high current levels below critical temperature

    Science.gov (United States)

    Boom, R. W. (Inventor)

    1967-01-01

    Operation of a superconducting magnet is considered. A method is described for; (1) obtaining a relatively high current in a superconducting magnet positioned in a bath of a gas refrigerant; (2) operating a superconducting magnet at a relatively high current level without training; and (3) operating a superconducting magnet containing a plurality of turns of a niobium zirconium wire at a relatively high current level without training.

  14. A high current, high speed pulser using avalanche transistors

    International Nuclear Information System (INIS)

    Hosono, Yoneichi; Hasegawa, Ken-ichi

    1985-01-01

    A high current, high speed pulser for the beam pulsing of a linear accelerator is described. It uses seven avalanche transistors in cascade. Design of a trigger circuit to obtain fast rise time is discussed. The characteristics of the pulser are : (a) Rise time = 0.9 ns (FWHM) and (d) Life time asymptotically equals 2000 -- 3000 hr (at 50 Hz). (author)

  15. Quality evaluation of concrete under compacting by vibration using resistance of electro current

    International Nuclear Information System (INIS)

    Nozaki, Yoshisugu

    2006-01-01

    Quality of concrete in structures is affected not only quality of materials; i.e. fresh concrete delivered to site but also placing and compaction works. Factors related to the latter are not studied minutely, and the works in site are judged and controlled by skilled person under his experience, and these process are said to the neck in QC and rationalization in construction site. The study to develop the evaluation system of fresh concrete quality is described in the paper, In the experiment, electrode was attached to formwork and resistance of electro current was recorded while vibrating. It can recognized that resistance is closely related to internal quality of concrete, so the resistance may be the effective index to know optimum compaction time in placing work.

  16. System for evaluating weld quality using eddy currents

    Science.gov (United States)

    Todorov, Evgueni I.; Hay, Jacob

    2017-12-12

    Electromagnetic and eddy current techniques for fast automated real-time and near real-time inspection and monitoring systems for high production rate joining processes. An eddy current system, array and method for the fast examination of welds to detect anomalies such as missed seam (MS) and lack of penetration (LOP) the system, array and methods capable of detecting and sizing surface and slightly subsurface flaws at various orientations in connection with at least the first and second weld pass.

  17. High Quality Model Predictive Control for Single Phase Grid Connected Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Zangeneh Bighash, Esmaeil; Sadeghzadeh, Seyed Mohammad; Ebrahimzadeh, Esmaeil

    2018-01-01

    Single phase grid-connected inverters with LCL filter are widely used to connect the photovoltaic systems to the utility grid. Among the presented control schemes, predictive control methods are faster and more accurate but are more complex to implement. Recently, the model-predictive control...... algorithm for single-phase inverter has been presented, where the algorithm implementation is straightforward. In the proposed approach, all switching states are tested in each switching period to achieve the control objectives. However, since the number of the switching states in single-phase inverter...... is low, the inverter output current has a high total harmonic distortions. In order to reduce the total harmonic distortions of the injected current, this paper presents a high-quality model-predictive control for one of the newest structure of the grid connected photovoltaic inverter, i.e., HERIC...

  18. Personality and Relationship Quality During the Transition From High School to Early Adulthood

    Science.gov (United States)

    Parker, Philip D.; Lüdtke, Oliver; Trautwein, Ulrich; Roberts, Brent W.

    2013-01-01

    The post–high school transition period is believed to be associated with considerable changes in social networks, yet longitudinal studies documenting these changes are scarce. To address this gap, the current research explored 3 relevant issues. First, changes in participants’ relationship characteristics during the transition from high school were examined. Second, the roles of personality traits as antecedents of these changes were studied. Third, the association between change in relationship characteristics and personality during the transition was explored. A sample of over 2,000 German emerging adults, surveyed before leaving school and then 2 years after the transition from high school, was assessed on personality traits and a multidimensional assessment of the quality of their relationships. Findings indicated that participants experienced mostly positive changes in relationship quality during the transition from high school and that antecedent personality at school was an important predictor of the nature of this change. Finally, change in relationship quality was found to be associated with personality change during the post-school transition. Findings indicated that personality traits may influence transition success and that change in relationships during this transition may influence personality development. The implications of the research for post-school transition success are discussed. PMID:22224909

  19. Void fraction in horizontal bulk flow boiling at high flow qualities

    International Nuclear Information System (INIS)

    Collado, Fancisco J.; Monne, Carlos; Pascau, Antonio

    2008-01-01

    In this work, a new thermodynamic prediction of the vapor void fraction in bulk flow boiling, which is the core process of many energy conversion systems, is analyzed. The current heat balance is based on the flow quality, which is closely related to the measured void fraction, although some correlation for the vapor-liquid velocity ratio is needed. So here, it is suggested to work with the 'static' or thermodynamic quality, which is directly connected to the void fraction through the densities of the phases. Thus, the relation between heat and the mixture enthalpy (here based on the thermodynamic quality instead of the flow one) should be analyzed in depth. The careful void fraction data taken by Thom during the 'Cambridge project' for horizontal saturated flow boiling with high flow qualities (≤0.8) have been used for this analysis. As main results, first, we have found that the applied heat and the increment of the proposed thermodynamic enthalpy mixture throughout the heated duct do not agree, and for closure, a parameter is needed. Second, it has been checked that this parameter is practically equal to the classic velocity ratio or 'slip' ratio, suggesting that it should be included in a true thermodynamic heat balance. Furthermore, it has been clearly possible to improve the 'Cambridge project' correlations for the 'slip' ratio, here based on inlet pressure and water velocity, and heat flux. The calculated void fractions compare quite well with the measured ones. Finally, the equivalence of the suggested new heat balance with the current one through the 'slip' ratio is addressed. Highlighted is the same new energetic relation for saturated flow boiling that has been recently confirmed by the authors for Knights data, also taken during the 'Cambridge project', which include not only horizontal but also vertical upwards flows with moderate outlet flow quality (≤0.2)

  20. High beam quality and high energy short-pulse laser with MOPA

    Science.gov (United States)

    Jin, Quanwei; Pang, Yu; Jiang, JianFeng; Tan, Liang; Cui, Lingling; Wei, Bin; Sun, Yinhong; Tang, Chun

    2018-03-01

    A high energy, high beam quality short-pulse diode-pumped Nd:YAG master oscillator power-amplifier (MOPA) laser with two amplifier stages is demonstrated. The two-rod birefringence compensation was used as beam quality controlling methods, which presents a short-pulse energy of 40 mJ with a beam quality value of M2 = 1.2 at a repetition rate of 400Hz. The MOPA system delivers a short-pulse energy of 712.5 mJ with a pulse width of 12.4 ns.The method of spherical aberration compensation is improved the beam quality, a M2 factor of 2.3 and an optical-to-optical efficiency of 27.7% is obtained at the maximum laser out power.The laser obtained 1.4J out energy with polarization integration.

  1. High quality-factor optical resonators

    International Nuclear Information System (INIS)

    Henriet, Rémi; Salzenstein, Patrice; Coillet, Aurélien; Saleh, Khaldoun; Chembo, Yanne K; Ristic, Davor; Ferrari, Maurizio; Mortier, Michel; Rasoloniaina, Alphonse; Dumeige, Yannick; Féron, Patrice; Cibiel, Gilles; Llopis, Olivier

    2014-01-01

    Various resonators are investigated for microwave photonic applications. Micro-sphere, disk and fiber ring resonators were designed, realized and characterized. Obtained quality factors are as high as Q = 10 10 . (paper)

  2. Transmission Level High Temperature Superconducting Fault Current Limiter

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, Gary [SuperPower, Inc., Schenectady, NY (United States)

    2016-10-05

    The primary objective of this project was to demonstrate the feasibility and reliability of utilizing high-temperature superconducting (HTS) materials in a Transmission Level Superconducting Fault Current Limiter (SFCL) application. During the project, the type of high-temperature superconducting material used evolved from 1st generation (1G) BSCCO-2212 melt cast bulk high-temperature superconductors to 2nd generation (2G) YBCO-based high-temperature superconducting tape. The SFCL employed SuperPower's “Matrix” technology, that offers modular features to enable scale up to transmission voltage levels. The SFCL consists of individual modules that contain elements and parallel inductors that assist in carrying the current during the fault. A number of these modules are arranged in an m x n array to form the current-limiting matrix.

  3. High current transistor pulse generator

    International Nuclear Information System (INIS)

    Nesterov, V.; Cassel, R.

    1991-05-01

    A solid state pulse generator capable of delivering high current trapezoidally shaped pulses into an inductive load has been developed at SLAC. Energy stored in the capacitor bank of the pulse generator is switched to the load through a pair of Darlington transistors. A combination of diodes and Darlington transistors is used to obtain trapezoidal or triangular shaped current pulses into an inductive load and to recover the remaining energy in the same capacitor bank without reversing capacitor voltage. The transistors work in the switch mode, and the power losses are low. The rack mounted pulse generators presently used at SLAC contain a 660 microfarad storage capacitor bank and can deliver 400 amps at 800 volts into inductive loads up to 3 mH. The pulse generators are used in several different power systems, including pulse to pulse bipolar power supplies and in application with current pulses distributed into different inductive loads. The current amplitude and discharge time are controlled by the central computer system through a specially developed multichannel controller. Several years of operation with the pulse generators have proven their consistent performance and reliability. 8 figs

  4. Identify High-Quality Protein Structural Models by Enhanced K-Means.

    Science.gov (United States)

    Wu, Hongjie; Li, Haiou; Jiang, Min; Chen, Cheng; Lv, Qiang; Wu, Chuang

    2017-01-01

    Background. One critical issue in protein three-dimensional structure prediction using either ab initio or comparative modeling involves identification of high-quality protein structural models from generated decoys. Currently, clustering algorithms are widely used to identify near-native models; however, their performance is dependent upon different conformational decoys, and, for some algorithms, the accuracy declines when the decoy population increases. Results. Here, we proposed two enhanced K -means clustering algorithms capable of robustly identifying high-quality protein structural models. The first one employs the clustering algorithm SPICKER to determine the initial centroids for basic K -means clustering ( SK -means), whereas the other employs squared distance to optimize the initial centroids ( K -means++). Our results showed that SK -means and K -means++ were more robust as compared with SPICKER alone, detecting 33 (59%) and 42 (75%) of 56 targets, respectively, with template modeling scores better than or equal to those of SPICKER. Conclusions. We observed that the classic K -means algorithm showed a similar performance to that of SPICKER, which is a widely used algorithm for protein-structure identification. Both SK -means and K -means++ demonstrated substantial improvements relative to results from SPICKER and classical K -means.

  5. Quality management manual for production of high quality cassava flour

    DEFF Research Database (Denmark)

    Dziedzoave, Nanam Tay; Abass, Adebayo Busura; Amoa-Awua, Wisdom K.

    The high quality cassava flour (HQCF) industry has just started to evolve in Africa and elsewhere. The sustainability of the growing industry, the profitability of small- and medium-scale enterprises (SMEs) that are active in the industry and good-health of consumers can best be guaranteed through...... the adoption of proper quality and food safety procedures. Cassava processing enterprises involved in the productionof HQCF must therefore be commited to the quality and food safety of the HQCF. They must have the right technology, appropriate processing machhinery, standard testing instruments...... and the necessary technical expertise. This quality manual was therefore developed to guide small- to medium-scale cassava in the design and implematation of Hazard Analysis Critical Control Point (HACCP) system and Good manufacturing Practices (GMP) plans for HQCF production. It describes the HQCF production...

  6. Beam brilliance investigation of high current ion beams at GSI heavy ion accelerator facility.

    Science.gov (United States)

    Adonin, A A; Hollinger, R

    2014-02-01

    In this work the emittance measurements of high current Ta-beam provided by VARIS (Vacuum Arc Ion Source) ion source are presented. Beam brilliance as a function of beam aperture at various extraction conditions is investigated. Influence of electrostatic ion beam compression in post acceleration gap on the beam quality is discussed. Use of different extraction systems (single aperture, 7 holes, and 13 holes) in order to achieve more peaked beam core is considered. The possible ways to increase the beam brilliance are discussed.

  7. Lattice Effects Due to High Currents in PEP-II

    International Nuclear Information System (INIS)

    Decker, F.-J.; Smith, H.; Turner, J.L.; SLAC

    2005-01-01

    The very high beam currents in the PEP-II B-Factory have caused many expected and unexpected effects: Synchrotron light fans move the beam pipe and cause dispersion; higher order modes cause excessive heating, e-clouds around the positron beam blow up its beam size. Here we describe an effect where the measured dispersion of the beam in the Low Energy Ring (LER) is different at high and at low beam currents. The dispersion was iteratively lowered by making anti-symmetric orbit bumps in many sextupole duplets, checking each time with a dispersion measurement where a dispersive kick is generated. This can be done parasitically during collisions. It was a surprise when checking the low current characterization data that there is a change. Subsequent high and low current measurements confirmed the effect. One source was believed to be located far away from any synchrotron radiation in the middle of a straight (PR12), away from sextupoles and skew quadrupoles and created a dispersion wave of about 70 mm at high current while at low current it is negligible

  8. LASL high-current proton storage rings

    International Nuclear Information System (INIS)

    Lawrence, G.P.; Cooper, R.K.; Hudgings, D.W.; Spalek, G.; Jason, A.J.; Higgins, E.F.; Gillis, R.E.

    1980-01-01

    The Proton Storage Ring at LAMPF is a high-current accumulator designed to convert long 800-MeV linac pulses into very short high-intensity proton bunches ideally suited to driving a pulsed polyenergetic neutron source. The Ring, authorized for construction at $19 million, will operate in a short-bunch high-frequency mode for fast neutron physics and a long-bunch low-frequency mode for thermal neutron-scattering programs. Unique features of the project include charge-changing injection with initial conversion from H - to H 0 , a high repetition rate fast-risetime extraction kicker, and high-frequency and first-harmonic bunching system

  9. 75 FR 41693 - Export Inspection and Weighing Waiver for High Quality Specialty Grains Transported in Containers

    Science.gov (United States)

    2010-07-19

    ... Specialty Grains Transported in Containers AGENCY: Grain Inspection, Packers and Stockyards Administration... rule to potentially make permanent the current waiver for high quality grain exported in containers... exported in containers that was established by a final rule on December 13, 2005 (70 FR 73556). This...

  10. High resolution eddy current microscopy

    Science.gov (United States)

    Lantz, M. A.; Jarvis, S. P.; Tokumoto, H.

    2001-01-01

    We describe a sensitive scanning force microscope based technique for measuring local variations in resistivity by monitoring changes in the eddy current induced damping of a cantilever with a magnetic tip oscillating above a conducting sample. To achieve a high sensitivity, we used a cantilever with an FeNdBLa particle mounted on the tip. Resistivity measurements are demonstrated on a silicon test structure with a staircase doping profile. Regions with resistivities of 0.0013, 0.0041, and 0.022 Ω cm are clearly resolved with a lateral resolution of approximately 180 nm. For this range of resistivities, the eddy current induced damping is found to depend linearly on the sample resistivity.

  11. Surface ionization ion source with high current

    International Nuclear Information System (INIS)

    Fang Jinqing; Lin Zhizhou; Yu Lihua; Zhan Rongan; Huang Guojun; Wu Jianhua

    1986-04-01

    The working principle and structure of a surface ionization ion source with high current is described systematically. Some technological keypoints of the ion source are given in more detail, mainly including: choosing and shaping of the material of the surface ionizer, heating of the ionizer, distributing of working vapour on the ionizer surface, the flow control, the cooling problem at the non-ionization surface and the ion optics, etc. This ion source has been used since 1972 in the electromagnetic isotope separator with 180 deg angle. It is suitable for separating isotopes of alkali metals and rare earth metals. For instance, in the case of separating Rubidium, the maximum ion current of Rbsup(+) extracted from the ion source is about 120 mA, the maximum ion current accepted by the receiver is about 66 mA, the average ion current is more than 25 mA. The results show that our ion source have advantages of high ion current, good characteristics of focusing ion beam, working stability and structure reliability etc. It may be extended to other fields. Finally, some interesting phenomena in the experiment are disccused briefly. Some problems which should be investigated are further pointed out

  12. Critical current enhancement in high Tc superconductors

    International Nuclear Information System (INIS)

    Jin, S.; Graebner, J.E.; Tiefel, T.H.

    1990-01-01

    Progress toward major technological applications of the bulk, high T c superconductors has been hindered by two major barriers, i.e., the Josephson weak-links at grain boundaries and the lack of sufficient intragrain flux pinning. It has been demonstrated that the weak link problem can be overcome by extreme alignment of grains such as in melt-textured-growth (MTG) materials. Modified or improved processing by various laboratories has produced further increased critical currents. However, the insufficient flux pinning seems to limit the critical current density in high fields to about 10 4 --10 5 A/cm 2 at 77K, which is not satisfactory for many applications. In this paper, processing, microstructure, and critical current behavior of the MTG type superconductors are described, and various processing possibilities for flux pinning enhancement are discussed

  13. Biotransformation of Organic Waste into High Quality Fertilizer

    DEFF Research Database (Denmark)

    Bryndum, Sofie

    Agriculture faces several challenges of future provision of nutrients such as limited P reserves and increasing prices of synthetic fertilizers and recycling of nutrients from organic waste can be an important strategy for the long-term sustainability of the agricultural systems. Organically...... and S, is often low; and (3) the unbalanced composition of nutrients rarely matches crop demands. Therefore the objective of this project was to investigate the potential for (1) recycling nutrients from agro-industrial wastes and (2) compost biotransformation into high-quality organic fertilizers...... other uses into fertilizer use would be unlikely. An estimated ~50 % of the total organic waste pool, primarily consisting of animal manure and waste from the processing of sugar cane, coffee, oil palm and oranges, is currently being re-used as “fertilizers”, meaning it is eventually returned...

  14. A current review of high speed railways experiences in Asia and Europe

    Science.gov (United States)

    Purba, Aleksander; Nakamura, Fumihiko; Dwsbu, Chatarina Niken; Jafri, Muhammad; Pratomo, Priyo

    2017-11-01

    High-Speed Railways (HSR) is currently regarded as one of the most significant technological breakthroughs in passenger transportation developed in the second half of the 20th century. At the beginning of 2008, there were about 10,000 kilometers of new high-speed lines in operation in Asia and Europe regions to provide high-speed services to passengers willing to pay for lower travel time and quality improvement in rail transport. And since 2010, HSR itself has received a great deal of attention in Indonesia. Some transportation analysts contend that Indonesia, particularly Java and Sumatera islands need a high-speed rail network to be economically competitive with countries in Asia and Europe. On April 2016, Indonesia-China consortium Kereta Cepat Indonesia China (KCIC) signed an engineering, procurement, and construction contract to build the HSR with a consortium of seven companies called the High-Speed Railway Contractor Consortium. The HSR is expected to debut by May 2019, offering a 45-minute trip covering a roughly 150 km route. However, building, maintaining and operating HSR line is expensive; it involves a significant amount of sunk costs and may substantially compromise both the transport policy of a country and the development of its transport sector for decades. The main objective of this paper is to discuss some characteristics of the HSR services from an economic viewpoint, while simultaneously developing an empirical framework that should help us to understand, in more detail, the factors determining the success of the HSR as transport alternative based on current experiences of selected Asian and European countries.

  15. Final report: High current capacity high temperature superconducting film based tape for high field magnets

    International Nuclear Information System (INIS)

    Ying Xin

    2000-01-01

    The primary goal of the program was to establish the process parameters for the continuous deposition of high quality, superconducting YBCO films on one meter lengths of buffered RABiTS tape using MOCVD and to characterize the potential utility of the resulting tapes in high field magnet applications

  16. High current high accuracy IGBT pulse generator

    International Nuclear Information System (INIS)

    Nesterov, V.V.; Donaldson, A.R.

    1995-05-01

    A solid state pulse generator capable of delivering high current triangular or trapezoidal pulses into an inductive load has been developed at SLAC. Energy stored in a capacitor bank of the pulse generator is switched to the load through a pair of insulated gate bipolar transistors (IGBT). The circuit can then recover the remaining energy and transfer it back to the capacitor bank without reversing the capacitor voltage. A third IGBT device is employed to control the initial charge to the capacitor bank, a command charging technique, and to compensate for pulse to pulse power losses. The rack mounted pulse generator contains a 525 μF capacitor bank. It can deliver 500 A at 900V into inductive loads up to 3 mH. The current amplitude and discharge time are controlled to 0.02% accuracy by a precision controller through the SLAC central computer system. This pulse generator drives a series pair of extraction dipoles

  17. New Pulsed Power Technology for High Current Accelerators

    International Nuclear Information System (INIS)

    Caporaso, G J

    2002-01-01

    Recent advances in solid-state modulators now permit the design of a new class of high current accelerators. These new accelerators will be able to operate in burst mode at frequencies of several MHz with unprecedented flexibility and precision in pulse format. These new modulators can drive accelerators to high average powers that far exceed those of any other technology and can be used to enable precision beam manipulations. New insulator technology combined with novel pulse forming lines and switching may enable the construction of a new type of high gradient, high current accelerator. Recent developments in these areas will be reviewed

  18. Quality Assurance Strategy for Existing Homes: Final Quality Management Primer for High Performing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Del Bianco, M.; Taggart, J.; Sikora, J.; Wood, A.

    2012-12-01

    This guide is designed to help Building America (BA) Teams understand quality management and its role in transitioning from conventional to high performance home building and remodeling. It explains what quality means, the value of quality management systems, the unique need for QMS when building high performing homes, and the first steps to a implementing a comprehensive QMS. This document provides a framework and context for BA teams when they encounter builders and remodelers.

  19. Quality Assurance Strategy for Existing Homes. Final Quality Management Primer for High Performing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Del Bianco, M. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Taggart, J. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Sikora, J. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Wood, A. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States)

    2012-12-01

    This guide is designed to help Building America (BA) teams understand quality management and its role in transitioning from conventional to high performance home building and remodeling. It explains what quality means, the value of quality management systems, the unique need for QMS when building high performing homes, and the first steps to a implementing a comprehensive QMS. This document provides a framework and context for BA teams when they encounter builders and remodelers.

  20. Physics issues of high bootstrap current tokamaks

    International Nuclear Information System (INIS)

    Ozeki, T.; Azumi, M.; Ishii, Y.

    1997-01-01

    Physics issues of a tokamak plasma with a hollow current profile produced by a large bootstrap current are discussed based on experiments in JT-60U. An internal transport barrier for both ions and electrons was obtained just inside the radius of zero magnetic shear in JT-60U. Analysis of the toroidal ITG microinstability by toroidal particle simulation shows that weak and negative shear reduces the toroidal coupling and suppresses the ITG mode. A hard beta limit was observed in JT-60U negative shear experiments. Ideal MHD mode analysis shows that the n = 1 pressure-driven kink mode is a plausible candidate. One of the methods to improve the beta limit against the kink mode is to widen the negative shear region, which can induce a broader pressure profile resulting in a higher beta limit. The TAE mode for the hollow current profile is less unstable than that for the monotonic current profile. The reason is that the continuum gaps near the zero shear region are not aligned when the radius of q min is close to the region of high ∇n e . Finally, a method for stable start-up for a plasma with a hollow current profile is describe, and stable sustainment of a steady-state plasma with high bootstrap current is discussed. (Author)

  1. Development and Testing of High Current Hollow Cathodes for High Power Hall Thrusters

    Science.gov (United States)

    Kamhawi, Hani; Van Noord, Jonathan

    2012-01-01

    NASA's Office of the Chief Technologist In-Space Propulsion project is sponsoring the testing and development of high power Hall thrusters for implementation in NASA missions. As part of the project, NASA Glenn Research Center is developing and testing new high current hollow cathode assemblies that can meet and exceed the required discharge current and life-time requirements of high power Hall thrusters. This paper presents test results of three high current hollow cathode configurations. Test results indicated that two novel emitter configurations were able to attain lower peak emitter temperatures compared to state-of-the-art emitter configurations. One hollow cathode configuration attained a cathode orifice plate tip temperature of 1132 degC at a discharge current of 100 A. More specifically, test and analysis results indicated that a novel emitter configuration had minimal temperature gradient along its length. Future work will include cathode wear tests, and internal emitter temperature and plasma properties measurements along with detailed physics based modeling.

  2. High-current electron accelerator for gas-laser pumping

    Energy Technology Data Exchange (ETDEWEB)

    Badaliants, G R; Mamikonian, V A; Nersisian, G Ts; Papanian, V O

    1978-11-26

    A high-current source of pulsed electron beams has been developed for the pumping of UV gas lasers. The parameters of the device are: energy of 0.3-0.7 MeV pulse duration of 30 ns and current density (in a high-pressure laser chamber) of 40-100 A/sq cm. The principal feature of the device is the use of a rectangular cold cathode with incomplete discharge along the surface of the high-permittivity dielectric. Cathodes made of stainless steel, copper, and graphite were investigated.

  3. Characteristics of a High Current Helicon Ion Source With High Monatomic Fraction

    International Nuclear Information System (INIS)

    Jung, Hwa-Dong; Chung, Kyoung-Jae; Hwang, Yong-Seok

    2006-01-01

    Applications of neutron need compact and high yield neutron sources as well as very intense neutron sources from giant devices such as accelerators. Ion source based neutron sources using nuclear fusion reactions such as D(d, 3He)n, D(t, 4He)n can meet the requirements. This type of neutron generators can be simply composed of an ion source and a target. High-performance neutron generators with high yield require ion sources with high beam current, high monatomic fraction and long lifetime. Helicon ion source can meet these requirements. To make high current ion source, characteristics of helicon plasma such as high plasma density can be utilized. Moreover, efficient plasma heating with RF power lead high fraction of monatomic ion beam. Here, Characteristics of helicon plasma sources are described. Design and its performances of a helicon ion source are presented

  4. NbN/AlN/NbN tunnel junctions with high current density up to 54 kA/cm2

    International Nuclear Information System (INIS)

    Wang, Z.; Kawakami, A.; Uzawa, Y.

    1997-01-01

    We report on progress in the development of high current density NbN/AlN/NbN tunnel junctions for applications as submillimeter wave superconductor-insulator-superconductor mixers. A very high current density up to 54 kA/cm 2 , roughly an order of magnitude larger than any reported results for all-NbN tunnel junctions, was achieved in the junctions with about 1 nm thick AlN barriers. The magnetic field and temperature dependence of critical supercurrents were measured to investigate the Josephson tunneling behavior of critical supercurrents in the high-J c junctions. The junctions showed high-quality junction characteristics with a large gap voltage of 5 mV and sharp quasiparticle current rise (ΔV g =0.1 mV). The R sg /R N ratio was about 5 with a V m value of 14 mV measured at 4.2 K. copyright 1997 American Institute of Physics

  5. Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of abdomen and pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sanghee (Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine (Korea, Republic of)); Yoon, Sang-Wook; Yoo, Seung-Min; Kim, Kyoung Ah; Kim, Sang Heum; Lee, Jong Tae (Dept. of Diagnostic Radiology, CHA Bundang Medical Center, CHA Univ. (Korea, Republic of)), email: jansons@cha.ac.kr; Ji, Young Geon (Preventive Medicine, CHA Bundang Medical Center, CHA Univ. (Korea, Republic of))

    2011-12-15

    Background. Tube current is an important determinant of radiation dose and image quality in X-ray-based examination. The combined automatic tube current modulation technique (ATCM) enables automatic adjustment of the tube current in various planes (x-y and z) based on the size and attenuation of the body area scanned. Purpose. To compare image quality and radiation dose of the ATCM with those of a fixed tube current technique (FTC) in CT of the abdomen and pelvis performed with a 16-slice multidetector row CT. Material and Methods. We reviewed 100 patients in whom initial and follow-up CT of the abdomen and pelvis were performed with FTC and ATCM. All acquisition parameters were identical in both techniques except for tube current. We recorded objective image noise in liver parenchyma, subjective image noise and diagnostic acceptability by using a five-point scale, radiation dose, and body mass index (BMI, kg/m2). Data were analyzed with parametric and non-parametric statistical tests. Results. There was no significant difference in image noise and diagnostic acceptability between two techniques. All subjects had acceptable subjective image noise in both techniques. The significant reduction in radiation dose (45.25% reduction) was noted with combined ATCM (P < 0.001). There was a significant linear statistical correlation between BMI and dose reduction (r = -0.78, P < 0.05). Conclusion. The ATCM for CT of the abdomen and pelvis substantially reduced radiation dose while maintaining diagnostic image quality. Patients with lower BMI showed more reduction in radiation dose

  6. Comparative study of active plasma lenses in high-quality electron accelerator transport lines

    Science.gov (United States)

    van Tilborg, J.; Barber, S. K.; Benedetti, C.; Schroeder, C. B.; Isono, F.; Tsai, H.-E.; Geddes, C. G. R.; Leemans, W. P.

    2018-05-01

    Electrically discharged active plasma lenses (APLs) are actively pursued in compact high-brightness plasma-based accelerators due to their high-gradient, tunable, and radially symmetric focusing properties. In this manuscript, the APL is experimentally compared with a conventional quadrupole triplet, highlighting the favorable reduction in the energy dependence (chromaticity) in the transport line. Through transport simulations, it is explored how the non-uniform radial discharge current distribution leads to beam-integrated emittance degradation and a charge density reduction at focus. However, positioning an aperture at the APL entrance will significantly reduce emittance degradation without additional loss of charge in the high-quality core of the beam. An analytical model is presented that estimates the emittance degradation from a short beam driving a longitudinally varying wakefield in the APL. Optimizing laser plasma accelerator operation is discussed where emittance degradation from the non-uniform discharge current (favoring small beams inside the APL) and wakefield effects (favoring larger beam sizes) is minimized.

  7. Measurement system of high voltage and high current measurements at INMETRO - Brazilian Institute for Metrology, Standardization and Industrial Quality; Sistema de medicao de alta tensao e alta corrente do INMETRO - Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Vitorio, Patricia Cals de O.; Franca, Ademir Martins de; Soares, Marco Aurelio; Pereira, Luiz Napoleao; Costa, Danielli Guimaraes; Moreira, Giselle Cobica; Nascimento, Paulo Roberto Mesquita [Instituto Nacional de Metrologia, Normalizacao e Qualidade Industrial (DIMCI/INMETRO), Duque de Caxias, RJ (Brazil). Diretoria de Metrologia Cientifica e Industrial], E-mail: latra@inmetro.gov.br

    2009-07-01

    This work presents the basic characteristics and uncertainties of the calibration equipment in high voltage and high current available at the INMETRO: system of measurement in alternating high voltage up to 200 kV, system of measurement in alternating current up to 2 k A, and system of measurement in continuous high voltage up to 150 kV.

  8. Inequality in Preschool Quality? Community-Level Disparities in Access to High-Quality Learning Environments

    Science.gov (United States)

    Bassok, Daphna; Galdo, Eva

    2016-01-01

    In recent years, unequal access to high-quality preschool has emerged as a growing public policy concern. Because of data limitations, it is notoriously difficult to measure disparities in access to early learning opportunities across communities and particularly challenging to quantify gaps in access to "high-quality" programs. Research…

  9. Consensus of best current management: the starting point for clinical quality assessment

    International Nuclear Information System (INIS)

    Hanks, G.E.; Kramer, S.

    1984-01-01

    Consensus of best current management developed by a rational and deliberative process can provide the basis for clinical quality assessment. When it is possible to arrive at consensus in a specific disease, this consensus should detail appropriate pretreatment evaluation and the details of the treatment. Committees of experts for each specific disease site can formulate the consensus and must document their decision based on information from the current world literature. The authors have observed that individuals formulating consensus of best current management do not strictly follow their own criteria, and that compliance in various strata of practice throughout the United States shows a greater deviation from consensus than anticipated and indeed this deviation crosses all types of practice. The authors have observed quite different outcomes for two groups of patients with Hodgkin's disease treated with the same processes (i.e., mantle field technology and adequate radiation dose, etc.). They were unable to identify the reason for an increased failure rate in one group of these patients until they looked at each individual mantle port film from the two groups of patients. They identified that one facility was not including the Hodgkin's disease in the treatment portal due to poor technical performance. This program of process verification may be important in evaluating quality for any disease site

  10. New initiatives for producing high current electron accelerators

    International Nuclear Information System (INIS)

    Faehl, R.J.; Keinigs, R.K.; Pogue, E.W.

    1996-01-01

    New classes of compact electron accelerators able to deliver multi-kiloamperes of pulsed 10-50 MeV electron beams are being studied. One class is based upon rf linac technology with dielectric-filled cavities. For materials with ε/ε o >>1, the greatly increased energy storage permits high current operation. The second type is a high energy injected betatron. Circulating current limits scale as Β 2 γ 3

  11. Morphodynamics of supercritical high-density turbidity currents

    NARCIS (Netherlands)

    Cartigny, M.

    2012-01-01

    Seafloor and outcrop observations combined with numerical and physical experiments show that turbidity currents are likely 1) to be in a supercritical flow state and 2) to carry high sediment concentrations (being of high-density). The thesis starts with an experimental study of bedforms

  12. Molecular Beam Epitaxy Growth of High Crystalline Quality LiNbO3

    Science.gov (United States)

    Tellekamp, M. Brooks; Shank, Joshua C.; Goorsky, Mark S.; Doolittle, W. Alan

    2016-12-01

    Lithium niobate is a multi-functional material with wide reaching applications in acoustics, optics, and electronics. Commercial applications for lithium niobate require high crystalline quality currently limited to bulk and ion sliced material. Thin film lithium niobate is an attractive option for a variety of integrated devices, but the research effort has been stagnant due to poor material quality. Both lattice matched and mismatched lithium niobate are grown by molecular beam epitaxy and studied to understand the role of substrate and temperature on nucleation conditions and material quality. Growth on sapphire produces partially coalesced columnar grains with atomically flat plateaus and no twin planes. A symmetric rocking curve shows a narrow linewidth with a full width at half-maximum (FWHM) of 8.6 arcsec (0.0024°), which is comparable to the 5.8 arcsec rocking curve FWHM of the substrate, while the film asymmetric rocking curve is 510 arcsec FWHM. These values indicate that the individual grains are relatively free of long-range disorder detectable by x-ray diffraction with minimal measurable tilt and twist and represents the highest structural quality epitaxial material grown on lattice mismatched sapphire without twin planes. Lithium niobate is also grown on lithium tantalate producing high quality coalesced material without twin planes and with a symmetric rocking curve of 193 arcsec, which is nearly equal to the substrate rocking curve of 194 arcsec. The surface morphology of lithium niobate on lithium tantalate is shown to be atomically flat by atomic force microscopy.

  13. Wind Diffusivity Current, QuikSCAT SeaWinds, 0.25 degrees, Global, Science Quality, Meridional

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA CoastWatch distributes science quality Ekman current (in zonal, meridional, and modulus sets) and Ekman upwelling data. This data begins with wind velocity...

  14. Wind Diffusivity Current, QuikSCAT SeaWinds, 0.25 degrees, Global, Science Quality, Zonal

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA CoastWatch distributes science quality Ekman current (in zonal, meridional, and modulus sets) and Ekman upwelling data. This data begins with wind velocity...

  15. Wind Diffusivity Current, QuikSCAT SeaWinds, 0.25 degrees, Global, Science Quality, Modulus

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA CoastWatch distributes science quality Ekman current (in zonal, meridional, and modulus sets) and Ekman upwelling data. This data begins with wind velocity...

  16. Liquid metal current collectors for high-speed rotating machinery

    International Nuclear Information System (INIS)

    Carr, S.L.

    1976-01-01

    Recent interest in superconducting motors and generators has created a renewed interest in homopolar machinery. Homopolar machine designs have always been limited by the need for compact, high-current, low-voltage, sliding electrical curent collectors. Conventional graphite-based solid brushes are inadequate for use in homopolar machines. Liquid metals, under certain conditions of relative sliding velocities, electrical currents, and magnetic fields are known to be capable of performing well in homopolar machines. An effort to explore the capabilities and limits of a tongue-and-groove style current collector, utilizing sodium-potassium eutectic alloy (NaK) as the working fluid in high sliding speed operation is reported here. A double current collector generator model with a 14.5-cm maximum rotor diameter, 20,000 rpm rotational capability, and electrical current carrying ability was constructed and operated successfully at a peripheral velocity of 125 m/s. The limiting factor in these experiments was a high-speed fluid-flow instability resulting in the ejection of the working fluid from the operating portions of the collectors. The effects of collector size and geometry, working fluid (NaK or water), and cover gas pressure are reported. Hydrodynamic frictional torque-speed curves are given for the two fluids and for several geometries. Electrical resistances as a function of peripheral velocity at 60 amperes are reported, and the phenomenology of the high-speed fluid-flow instabilities is discussed. The possibility of long-term high-speed operation of current collectors of the tongue-and-groove type, along with experimental and theoretical hydrodynamic friction losses at high peripheral velocities, is considered

  17. Design of high current injector for SPring-8

    International Nuclear Information System (INIS)

    Yoshikawa, H.; Nakamura, N.; Mizuno, A.; Suzuki, S.; Hori, T.; Yanagida, K.; Mashiko, K.; Yokomizo, H.

    1992-01-01

    The linac of SPring-8, large synchrotron radiation facility of Japan, has the option which is positron operation modes. The electron gun of this linac is designed on base of the optimization for a high current beam to get positrons as many as possible. But otherwise this linac should be used as an accurate electron beam generator for commissioning on the whole facility. This report shows differences of the beam specification between a high current beam and a low current beam. The bunching section of this linac has just been constructed this summer at Tokai-Lab. of JAERI to be confirmed with the specification. (author). 3 refs., 1 tab., 4 figs

  18. [Implementation of quality management in medical rehabilitation--current challenges for rehabilitation facilities].

    Science.gov (United States)

    Enge, M; Koch, A; Müller, T; Vorländer, T

    2010-12-01

    The legal responsibilities imposed upon rehabilitation facilities under section 20 (2a) SGB IX, necessitate fundamental decisions to be taken regarding the development of quality management systems over and above the existing framework. This article is intended to provide ideas and suggestions to assist rehabilitation facilities in implementing a quality management system, which is required in addition to participation in the quality assurance programmes stipulated by the rehabilitation carriers. In this context, the additional internal benefit a functioning quality management system can provide for ensuring a high level of quality and for maintaining the competitiveness of the rehabilitation facility should be taken into account. The core element of these observations, hence, is a list of requirements which enables assessment of the quality of consultants' performance in setting up a quality management system. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Development of high current electron beam generator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byeong Cheol; Lee, Jong Min; Kim, Sun Kook [and others

    1997-05-01

    A high-current electron beam generator has been developed. The energy and the average current of the electron beam are 2 MeV and 50 mA, respectively. The electron beam generator is composed of an electron gun, RF acceleration cavities, a 260-kW RF generator, electron beam optics components, and control system, etc. The electron beam generator will be used for the development of a millimeter-wave free-electron laser and a high average power infrared free-electron laser. The machine will also be used as a user facility in nuclear industry, environment industry, semiconductor industry, chemical industry, etc. (author). 15 tabs., 85 figs.

  20. Development of high current electron beam generator

    International Nuclear Information System (INIS)

    Lee, Byeong Cheol; Lee, Jong Min; Kim, Sun Kook

    1997-05-01

    A high-current electron beam generator has been developed. The energy and the average current of the electron beam are 2 MeV and 50 mA, respectively. The electron beam generator is composed of an electron gun, RF acceleration cavities, a 260-kW RF generator, electron beam optics components, and control system, etc. The electron beam generator will be used for the development of a millimeter-wave free-electron laser and a high average power infrared free-electron laser. The machine will also be used as a user facility in nuclear industry, environment industry, semiconductor industry, chemical industry, etc. (author). 15 tabs., 85 figs

  1. Emblems of Quality in Higher Education. Developing and Sustaining High-Quality Programs.

    Science.gov (United States)

    Haworth, Jennifer Grant; Conrad, Clifton F.

    This book proposes an "engagement" theory of program quality to evaluate and improve higher education programs at all degree levels. Based on interviews with 781 participants in a national study of Masters degree programs, it focuses on the interactive roles of students, faculty, and administrators in developing high-quality programs…

  2. High critical current density YBCO films and fabrication of dc-SQUIDs

    CERN Document Server

    Kuriki, S; Kawaguchi, Y; Matsuda, M; Otowa, T

    2002-01-01

    In order to improve the sensitivity of SQUID magnetometers made of high-T sub c films, we have studied the conditions of pulsed-laser deposition of YBCO films. Among the different deposition parameters examined, extensive degassing of the vacuum chamber before and precise control of the substrate temperature during the film deposition were found effective for obtaining high critical temperature T sub c and high critical current density J sub c. It was also found that the residual-resistance ratio has a clear correlation with J sub c , indicating that it can be a good, and easy to measure, index of the film quality. Films having T sub c approx 89-90 K and J sub c >= 5x10 sup 6 A cm sup - sup 2 at 77 K were used to fabricate SQUIDs without a pickup loop. Grain-boundary junctions formed on bicrystal substrates with a 30 deg. misorientation angle exhibited I sub c R sub n values of more than 100 mu V at 77 K. The well-known scaling behaviour of the relation I sub c R sub n propor to (J sup G sup B sub c) sup 1 su...

  3. High-current proton accelerators-meson factories

    International Nuclear Information System (INIS)

    Dmitrievskij, V.P.

    1979-01-01

    A possibility of usage of accelerators of neutron as well as meson factories is considered. Parameters of linear and cyclic accelerators are given, which are employed as meson factories and as base for developing intense neutron generators. It is emphasized that the principal aim of developing neutron generators on the base of high current proton accelerators is production of intense neutron fluxes with a present energy spectrum. Production of tens-and-hundreds milliampere currents at the energy of 800-1000 MeV is considered at present for two types of accelerating facilities viz. linear accelerators under continuous operating conditions and cyclotrons with strong focusing. Quantitative evaluations of developing high-efficiency linear and cyclic accelerators are considered. The basic parameters of an ccelerating complex are given, viz. linear accelerator-injector and 800 MeV isochronous cyclotron. The main problems associated with their realization are listed [ru

  4. Void fraction in horizontal bulk flow boiling at high flow qualities

    Energy Technology Data Exchange (ETDEWEB)

    Collado, Fancisco J.; Monne, Carlos [Dpto. de Ingenieria Mecanica, Universidad de Zaragoza-CPS, Maria de Luna 3, 50018-Zaragoza (Spain); Pascau, Antonio [Dpto. de Ciencia de los Materiales y Fluidos, Universidad de Zaragoza-CPS, Maria de Luna 3, 50018-Zaragoza (Spain)

    2008-04-15

    In this work, a new thermodynamic prediction of the vapor void fraction in bulk flow boiling, which is the core process of many energy conversion systems, is analyzed. The current heat balance is based on the flow quality, which is closely related to the measured void fraction, although some correlation for the vapor-liquid velocity ratio is needed. So here, it is suggested to work with the 'static' or thermodynamic quality, which is directly connected to the void fraction through the densities of the phases. Thus, the relation between heat and the mixture enthalpy (here based on the thermodynamic quality instead of the flow one) should be analyzed in depth. The careful void fraction data taken by Thom during the 'Cambridge project' for horizontal saturated flow boiling with high flow qualities ({<=}0.8) have been used for this analysis. As main results, first, we have found that the applied heat and the increment of the proposed thermodynamic enthalpy mixture throughout the heated duct do not agree, and for closure, a parameter is needed. Second, it has been checked that this parameter is practically equal to the classic velocity ratio or 'slip' ratio, suggesting that it should be included in a true thermodynamic heat balance. Furthermore, it has been clearly possible to improve the 'Cambridge project' correlations for the 'slip' ratio, here based on inlet pressure and water velocity, and heat flux. The calculated void fractions compare quite well with the measured ones. Finally, the equivalence of the suggested new heat balance with the current one through the 'slip' ratio is addressed. Highlighted is the same new energetic relation for saturated flow boiling that has been recently confirmed by the authors for Knights data, also taken during the 'Cambridge project', which include not only horizontal but also vertical upwards flows with moderate outlet flow quality ({<=}0.2). (author)

  5. Testing of quality of welded joints using heavy-current pulse X-ray apparatuses

    International Nuclear Information System (INIS)

    Gusev, E.A.; Firstov, V.G.

    1988-01-01

    The possibilities of carrying out of radiographic and electroradiographic testing of quality of welded joints using heavy-current pulse X-ray apparatuses under the mode of single pulses are shown. Basic quantitative characteristics of radiographic testing permitting to detect the focus distance, sensitivity behaviour and optical density of image are presented. Peculiarities of electroradiographic image formation under the mode of single pulses of nanosecond range are analysed. The outlook of heavy-current pulse X-ray apparatus application under the mode of single pulses in industry is estimated

  6. Research on high beam-current accelerators

    International Nuclear Information System (INIS)

    Keefe, D.

    1981-01-01

    In this review of research being undertaken at present in the US on accelerating devices and concepts of a novel nature, both non-collective systems, including high-current rf linacs and a variety of induction linacs, and also collective systems are considered. (U.K.)

  7. High current ion source development at Frankfurt

    Energy Technology Data Exchange (ETDEWEB)

    Volk, K.; Klein, H.; Lakatos, A.; Maaser, A.; Weber, M. [Frankfurt Univ. (Germany). Inst. fuer Angewandte Physik

    1995-11-01

    The development of high current positive and negative ion sources is an essential issue for the next generation of high current linear accelerators. Especially, the design of the European Spallation Source facility (ESS) and the International Fusion Material Irradiation Test Facility (IFMIF) have increased the significance of high brightness hydrogen and deuterium sources. As an example, for the ESS facility, two H{sup -}-sources each delivering a 70 mA H{sup -}-beam in 1.45 ms pulses at a repetition rate of 50 Hz are necessary. A low emittance is another important prerequisite. The source must operate, while meeting the performance requirements, with a constancy and reliability over an acceptable period of time. The present paper summarizes the progress achieved in ion sources development of intense, single charge, positive and negative ion beams. (author) 16 figs., 7 refs.

  8. High current ion source development at Frankfurt

    International Nuclear Information System (INIS)

    Volk, K.; Klein, H.; Lakatos, A.; Maaser, A.; Weber, M.

    1995-01-01

    The development of high current positive and negative ion sources is an essential issue for the next generation of high current linear accelerators. Especially, the design of the European Spallation Source facility (ESS) and the International Fusion Material Irradiation Test Facility (IFMIF) have increased the significance of high brightness hydrogen and deuterium sources. As an example, for the ESS facility, two H - -sources each delivering a 70 mA H - -beam in 1.45 ms pulses at a repetition rate of 50 Hz are necessary. A low emittance is another important prerequisite. The source must operate, while meeting the performance requirements, with a constancy and reliability over an acceptable period of time. The present paper summarizes the progress achieved in ion sources development of intense, single charge, positive and negative ion beams. (author) 16 figs., 7 refs

  9. High pressure, high current, low inductance, high reliability sealed terminals

    Science.gov (United States)

    Hsu, John S [Oak Ridge, TN; McKeever, John W [Oak Ridge, TN

    2010-03-23

    The invention is a terminal assembly having a casing with at least one delivery tapered-cone conductor and at least one return tapered-cone conductor routed there-through. The delivery and return tapered-cone conductors are electrically isolated from each other and positioned in the annuluses of ordered concentric cones at an off-normal angle. The tapered cone conductor service can be AC phase conductors and DC link conductors. The center core has at least one service conduit of gate signal leads, diagnostic signal wires, and refrigerant tubing routed there-through. A seal material is in direct contact with the casing inner surface, the tapered-cone conductors, and the service conduits thereby hermetically filling the interstitial space in the casing interior core and center core. The assembly provides simultaneous high-current, high-pressure, low-inductance, and high-reliability service.

  10. Long quantum channels for high-quality entanglement transfer

    International Nuclear Information System (INIS)

    Banchi, L; Apollaro, T J G; Cuccoli, A; Verrucchi, P; Vaia, R

    2011-01-01

    High-quality quantum-state and entanglement transfer can be achieved in an unmodulated spin bus operating in the ballistic regime, which occurs when the endpoint qubits A and B are nonperturbatively coupled to the chain by a suitable exchange interaction j 0 . Indeed, the transition amplitude characterizing the transfer quality exhibits a maximum for a finite optimal value j opt 0 (N), where N is the channel length. We show that j opt 0 (N) scales as N -1/6 for large N and that it ensures a high-quality entanglement transfer even in the limit of arbitrarily long channels, almost independently of the channel initialization. For instance, for any chain length the average quantum-state transmission fidelity exceeds 90% and decreases very little in a broad neighbourhood of j opt 0 (N). We emphasize that, taking the reverse point of view, should j 0 be experimentally constrained, high-quality transfer can still be obtained by adjusting the channel length to its optimal value. (paper)

  11. A self-powered thin-film radiation detector using intrinsic high-energy current

    Energy Technology Data Exchange (ETDEWEB)

    Zygmanski, Piotr, E-mail: pzygmanski@LROC.HARVARD.EDU, E-mail: Erno-Sajo@uml.edu [Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115 (United States); Sajo, Erno, E-mail: pzygmanski@LROC.HARVARD.EDU, E-mail: Erno-Sajo@uml.edu [Department of Physics and Applied Physics, Medical Physics Program, University of Massachusetts Lowell, Lowell, Massachusetts 01854 (United States)

    2016-01-15

    Purpose: The authors introduce a radiation detection method that relies on high-energy current (HEC) formed by secondary charged particles in the detector material, which induces conduction current in an external readout circuit. Direct energy conversion of the incident radiation powers the signal formation without the need for external bias voltage or amplification. The detector the authors consider is a thin-film multilayer device, composed of alternating disparate electrically conductive and insulating layers. The optimal design of HEC detectors consists of microscopic or nanoscopic structures. Methods: Theoretical and computational developments are presented to illustrate the salient properties of the HEC detector and to demonstrate its feasibility. In this work, the authors examine single-sandwiched and periodic layers of Cu and Al, and Au and Al, ranging in thickness from 100 nm to 300 μm and separated by similarly sized dielectric gaps, exposed to 120 kVp x-ray beam (half-value thickness of 4.1 mm of Al). The energy deposition characteristics and the high-energy current were determined using radiation transport computations. Results: The authors found that in a dual-layer configuration, the signal is in the measurable range. For a defined total detector thickness in a multilayer structure, the signal sharply increases with decreasing thickness of the high-Z conductive layers. This paper focuses on the computational results while a companion paper reports the experimental findings. Conclusions: Significant advantages of the device are that it does not require external power supply and amplification to create a measurable signal; it can be made in any size and geometry, including very thin (sub-millimeter to submicron) flexible curvilinear forms, and it is inexpensive. Potential applications include medical dosimetry (both in vivo and external), radiation protection, and other settings where one or more of the above qualities are desired.

  12. Identifying suitable substrates for high-quality graphene-based heterostructures

    Science.gov (United States)

    Banszerus, L.; Janssen, H.; Otto, M.; Epping, A.; Taniguchi, T.; Watanabe, K.; Beschoten, B.; Neumaier, D.; Stampfer, C.

    2017-06-01

    We report on a scanning confocal Raman spectroscopy study investigating the strain-uniformity and the overall strain and doping of high-quality chemical vapour deposited (CVD) graphene-based heterostuctures on a large number of different substrate materials, including hexagonal boron nitride (hBN), transition metal dichalcogenides, silicon, different oxides and nitrides, as well as polymers. By applying a hBN-assisted, contamination free, dry transfer process for CVD graphene, high-quality heterostructures with low doping densities and low strain variations are assembled. The Raman spectra of these pristine heterostructures are sensitive to substrate-induced doping and strain variations and are thus used to probe the suitability of the substrate material for potential high-quality graphene devices. We find that the flatness of the substrate material is a key figure for gaining, or preserving high-quality graphene.

  13. Relations of Parenting Quality, Interparental Conflict, and Overnights with Mental Health Problems of Children in Divorcing Families with High Legal Conflict

    Science.gov (United States)

    Sandler, Irwin N.; Wheeler, Lorey A.; Braver, Sanford L.

    2013-01-01

    The current study examined the associations between child mental health problems and the quality of maternal and paternal parenting, and how these associations were moderated by three contextual factors, quality of parenting by the other parent, interparental conflict, and the number of overnights parents had with the child. Data for the current study come from a sample of divorcing families who are in high legal conflict over developing or maintaining a parenting plan following divorce. Analyses revealed that the associations between child mental health problems and positive maternal and paternal parenting were moderated by the quality of parenting provided by the other parent and by the number of overnights children spent with parents, but not by the level of interparental conflict. When both parenting by the other parent and number of overnights were considered in the same model, only number of overnights moderated the relations between parenting and child behavior problems. The results support the proposition that the well-being of children in high conflict divorcing families is better when they spend adequate time with at least one parent who provides high quality parenting. PMID:24098960

  14. High current density magnets for INTOR and TIBER

    International Nuclear Information System (INIS)

    Miller, J.R.; Henning, C.D.; Kerns, J.A.; Slack, D.S.; Summers, L.T.; Zbasnik, J.P.

    1986-12-01

    The adoption of high current density, high field, superconducting magnets for INTOR and TIBER would prove beneficial. When combined with improved radiation tolerance of the magnets to minimize the inner leg shielding, a substantial reduction in machine dimensions and capital costs can be achieved. Fortunately, cable-in-conduit conductors (CICC) which are capable of the desired enhancements are being developed. Because conductor stability in a CICC depends more on the trapped helium enthalpy, rather than the copper resistivity, higher current densities of the order of 40 A/mm 2 at 12 T are possible. Radiation damage to the copper stabilizer is less important because the growth in resistance is a second-order effect on stability. Such CICC conductors lend themselves naturally to niobium-tin utilization, with the benefits of the high current-sharing temperature of this material being taken to advantage in absorbing radiation heating. When the helium coolant is injected at near the critical pressure, Joule-Thompson expansion in the flow path tends to stabilize the fluid temperature at under 6 K. Thus, higher fields, as well as higher current densities, can be considered for INTOR or TIBER

  15. The impact of switching capacitor banks with very high inrush current on switchgear

    NARCIS (Netherlands)

    Smeets, R.P.P.; Wiggers, R.; Bannink, H.; Kuivenhoven, S.; Chakraborty, S.; Sandolache, G.

    2012-01-01

    Capacitor banks are installed in an increasing number in order to control power quality issues in the transmission and distribution networks. Due to load fluctuation, switching of capacitor banks is normally a daily operation. Although the current to be switched (e.g. the normal load current) is far

  16. Certifying leaders? high-quality management practices and healthy organisations: an ISO-9000 based standardisation approach.

    Science.gov (United States)

    Montano, Diego

    2016-08-05

    The present study proposes a set of quality requirements to management practices by taking into account the empirical evidence on their potential effects on health, the systemic nature of social organisations, and the current conceptualisations of management functions within the framework of comprehensive quality management systems. Systematic reviews and meta-analyses focusing on the associations between leadership and/or supervision and health in occupational settings are evaluated, and the core elements of an ISO 9001 standardisation approach are presented. Six major occupational health requirements to high-quality management practices are identified pertaining to communication processes, organisational justice, role clarity, decision making, social influence processes and management support. It is concluded that the quality of management practices may be improved by developing a quality management system of management practices that ensures not only conformity to product but also to occupational safety and health requirements. Further research may evaluate the practicability of the proposed approach.

  17. High short-circuit current density CdTe solar cells using all-electrodeposited semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Echendu, O.K., E-mail: oechendu@yahoo.com; Fauzi, F.; Weerasinghe, A.R.; Dharmadasa, I.M.

    2014-04-01

    CdS/CdTe and ZnS/CdTe n–n heterojunction solar cells have been fabricated using all-electrodeposited semiconductors. The best devices show remarkable high short-circuit current densities of 38.5 mAcm{sup −2} and 47.8 mAcm{sup −2}, open-circuit voltages of 630 mV and 646 mV and conversion efficiencies of 8.0% and 12.0% respectively. The major strength of these device structures lies in the combination of n–n heterojunction with a large Schottky barrier at the n-CdTe/metal back contact which provides the required band bending for the separation of photo-generated charge carriers. This is in addition to the use of a high quality n-type CdTe absorber layer with high electron mobility. The potential barrier heights estimated for these devices from the current–voltage characteristics exceed 1.09 eV and 1.13 eV for CdS/CdTe and ZnS/CdTe cells respectively. The diode rectification factors of both devices are in excess of four orders of magnitude with reverse saturation current densities of 1.0 × 10{sup −7} Acm{sup −2} and 4.0 × 10{sup −7} Acm{sup −2} respectively. These all-electrodeposited solar cell device structures are currently being studied and developed as an alternative to the well-known p–n junction structures which utilise chemical bath-deposited CdS. The preliminary material growth, device fabrication and assessment results are presented in this paper. - Highlights: • Two-electrode deposition. • High J{sub sc} Schottky barrier solar cells. • CdCl{sub 2} + CdF{sub 2} treatment.

  18. Current sharing effect on the current instability and allowable temperature rise of composite high-TC superconductors

    International Nuclear Information System (INIS)

    Romanovskii, V.R.; Watanabe, K.; Awaji, S.; Nishijima, G.; Takahashi, Ken-ichiro

    2004-01-01

    To understand the basic mechanisms of the thermal runaway phenomenon, the limiting margin of the current instability, which may spontaneously occur in composite high-T C superconductors like multifilament Bi-based wire or tape, is derived under DC magnetic field. The current sharing and allowable temperature rise effects were considered. A static zero-dimensional model was utilized to describe the basic formulae dealing with the peculiarities of the non-isothermal change of superconducting composite voltage-current characteristic. The boundary of allowable stable values of the temperature, electric field and current are derived analytically. It was shown that permissible values of the current and electric field might be higher than those determined by use of the standard critical current criterion. In consequence of this feature, the noticeable allowable temperature rise of the composite superconductor before its transition to the normal state may be seen. The criterion for complete thermal stability condition is written describing the state when temperature of the composite equals critical temperature of a superconductor and the transport current flows stably only in matrix. The performed analysis also proves the existence of value of the volume fraction of a superconductor in composite at which its current-carrying capacity has minimum. These peculiarities are due to the stable current redistribution between superconductor and stabilizing matrix. Therefore, the current sharing not only leads to the matrix/superconductor ratio effect on the stable operating characteristics of the composite high-T C superconductors but also becomes important in the adequate description of quench process in the high-T C superconducting magnets

  19. Facile Formation of High-quality InGaN/GaN Quantum-disks-in-Nanowires on Bulk-Metal Substrates for High-power Light-emitters

    KAUST Repository

    Zhao, Chao; Ng, Tien Khee; Wei, Nini; Prabaswara, Aditya; Alias, Mohd Sharizal; Janjua, Bilal; Shen, Chao; Ooi, Boon S.

    2016-01-01

    High-quality nitride materials grown on scalable and low-cost metallic substrates are considerably attractive for high-power light emitters. We demonstrate here, for the first time, the high-power red (705 nm) InGaN/GaN quantum-disks (Qdisks)-in-nanowire light-emitting diodes (LEDs) self-assembled directly on metal-substrate. The LEDs exhibited a low turn-on voltage of ~2 V without efficiency droop up to injection current of 500 mA (1.6 kA/cm2) at ~5 V. This is achieved through the direct growth and optimization of high-quality nanowires on titanium (Ti) coated bulk polycrystalline-molybdenum (Mo) substrates. We performed extensive studies on the growth mechanisms, obtained high-crystal-quality nanowires, and confirmed the epitaxial relationship between the cubic titanium nitride (TiN) transition layer and the hexagonal nanowires. The growth of nanowires on all-metal stack of TiN/Ti/Mo enables simultaneous implementation of n-metal contact, reflector and heat-sink, which greatly simplifies the fabrication process of high-power light emitters. Our work ushers in a practical platform for high-power nanowires light emitters, providing versatile solutions for multiple cross-disciplinary applications that are greatly enhanced by leveraging on the chemical stability of nitride materials, large specific surface of nanowires, chemical lift-off ready layer structures, and reusable Mo substrates.

  20. Facile Formation of High-quality InGaN/GaN Quantum-disks-in-Nanowires on Bulk-Metal Substrates for High-power Light-emitters

    KAUST Repository

    Zhao, Chao

    2016-01-08

    High-quality nitride materials grown on scalable and low-cost metallic substrates are considerably attractive for high-power light emitters. We demonstrate here, for the first time, the high-power red (705 nm) InGaN/GaN quantum-disks (Qdisks)-in-nanowire light-emitting diodes (LEDs) self-assembled directly on metal-substrate. The LEDs exhibited a low turn-on voltage of ~2 V without efficiency droop up to injection current of 500 mA (1.6 kA/cm2) at ~5 V. This is achieved through the direct growth and optimization of high-quality nanowires on titanium (Ti) coated bulk polycrystalline-molybdenum (Mo) substrates. We performed extensive studies on the growth mechanisms, obtained high-crystal-quality nanowires, and confirmed the epitaxial relationship between the cubic titanium nitride (TiN) transition layer and the hexagonal nanowires. The growth of nanowires on all-metal stack of TiN/Ti/Mo enables simultaneous implementation of n-metal contact, reflector and heat-sink, which greatly simplifies the fabrication process of high-power light emitters. Our work ushers in a practical platform for high-power nanowires light emitters, providing versatile solutions for multiple cross-disciplinary applications that are greatly enhanced by leveraging on the chemical stability of nitride materials, large specific surface of nanowires, chemical lift-off ready layer structures, and reusable Mo substrates.

  1. Preparation and characterization of high-Tc superconducting thin films with high critical current densities

    International Nuclear Information System (INIS)

    Vase, P.

    1991-08-01

    The project was carried out in relation to possible cable and electronics applications of high-T c materials. Laser ablation was used as the deposition technique because of its stoichiometry conservation. Films were made in the YBa 2 Cu 3 O 7 compound due to its relatively simple stoichiometry compared to other High-T c compounds. Much attention was paid to the critical current density. A very high critical current density was reached. By using texture analysis by X-ray diffraction, it was found that films with high critical current densities were epitaxial, while films with low critical current densities contained several crystalline orientations. Four techniques for patterning the films were used - photo lithography and wet etch, laser ablation lithography, laser writing and electron beam lithography and ion milling. Sub-micron patterning has been demonstrated without degradation of the superconducting properties. The achieved patterning resolution is sufficient for preparation of many superconducting components. (AB)

  2. Development of a high brightness, high current SRF photo-electron source for ERL applications

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, Axel [Helmholtz-Zentrum Berlin (Germany); Collaboration: bERLinPro Team

    2016-07-01

    Energy recovery linacs (ERL) offer the potential to combine major beam properties of the two main domains of particle accelerators: The low emittance of linear accelerators and the high average beam current of storage rings, while also allowing to compress to short bunches below the ps regime. This makes among other applications ERLs an ideal candidate for future light sources. The beam properties of the ERL are given by the performance of the injection section and hence of the beam source. Helmholtz-Zentrum Berlin is currently designing and building a high average current all superconducting CW driven ERL as a prototype to demonstrate low normalized beam emittance of 1 mm*mrad at 100 mA and short pulses of about 2 ps. In this contribution we discuss the development of this class of a high brightness, high current SRF photo-electron source and present recent commissioning results. Also, alternative approaches at other laboratories are shortly reviewed.

  3. The characterization of high quality multicrystalline silicon by the electron beam induced current method

    International Nuclear Information System (INIS)

    Chen, J; Sekiguchi, T; Nara, S; Yang, D

    2004-01-01

    Multicrystalline silicon (mc-Si) manufactured by a multi-stage solidification control casting method has been characterized by the electron beam induced current (EBIC) method. The average diffusion length of the ingot was over 250 μm, which was much longer than that of conventional mc-Si. The EBIC study revealed that the electrical activities of grain boundaries (GBs) varied with the ingot position due to the impurity contamination level. The main impurity detected was iron. The concentration of iron in the central position was much lower than that at the bottom and top positions. GBs in the central position showed no significant EBIC contrast at 300 K, suggesting low contamination level. GBs in the top and bottom positions, however, showed strong EBIC contrast at 300 K, suggesting high contamination level. At 100 K, a denuded zone with bright contrast developed around GBs in the top and bottom positions. The existence of the denuded zone suggested that impurities were gettered at the GBs. It was considered that the variation of the diffusion length in the ingot was related to the variation of recombination activities of GBs in the different positions, which mainly depended on the impurity contamination

  4. A high current density DC magnetohydrodynamic (MHD) micropump

    NARCIS (Netherlands)

    Homsy, Alexandra; Koster, Sander; Hogen-Koster, S.; Eijkel, Jan C.T.; van den Berg, Albert; Lucklum, F.; Verpoorte, E.; de Rooij, Nico F.

    2005-01-01

    This paper describes the working principle of a DC magnetohydrodynamic (MHD) micropump that can be operated at high DC current densities (J) in 75-µm-deep microfluidic channels without introducing gas bubbles into the pumping channel. The main design feature for current generation is a micromachined

  5. A high current density DC magnetohydrodynamic (MHD) micropump

    NARCIS (Netherlands)

    Homsy, A; Koster, Sander; Eijkel, JCT; van den Berg, A; Lucklum, F; Verpoorte, E; de Rooij, NF

    2005-01-01

    This paper describes the working principle of a DC magnetohydrodynamic (MHD) micropump that can be operated at high DC current densities (J) in 75-mu m-deep microfluidic channels without introducing gas bubbles into the pumping channel. The main design feature for current generation is a

  6. Key elements of high-quality practice organisation in primary health care: a systematic review.

    Science.gov (United States)

    Crossland, Lisa; Janamian, Tina; Jackson, Claire L

    2014-08-04

    To identify elements that are integral to high-quality practice and determine considerations relating to high-quality practice organisation in primary care. A narrative systematic review of published and grey literature. Electronic databases (PubMed, CINAHL, the Cochrane Library, Embase, Emerald Insight, PsycInfo, the Primary Health Care Research and Information Service website, Google Scholar) were searched in November 2013 and used to identify articles published in English from 2002 to 2013. Reference lists of included articles were searched for relevant unpublished articles and reports. Data were configured at the study level to allow for the inclusion of findings from a broad range of study types. Ten elements were most often included in the existing organisational assessment tools. A further three elements were identified from an inductive thematic analysis of descriptive articles, and were noted as important considerations in effective quality improvement in primary care settings. Although there are some validated tools available to primary care that identify and build quality, most are single-strategy approaches developed outside health care settings. There are currently no validated organisational improvement tools, designed specifically for primary health care, which combine all elements of practice improvement and whose use does not require extensive external facilitation.

  7. High Quality Data for Grid Integration Studies

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, Andrew; Draxl, Caroline; Sengupta, Manajit; Hodge, Bri-Mathias

    2017-01-22

    As variable renewable power penetration levels increase in power systems worldwide, renewable integration studies are crucial to ensure continued economic and reliable operation of the power grid. The existing electric grid infrastructure in the US in particular poses significant limitations on wind power expansion. In this presentation we will shed light on requirements for grid integration studies as far as wind and solar energy are concerned. Because wind and solar plants are strongly impacted by weather, high-resolution and high-quality weather data are required to drive power system simulations. Future data sets will have to push limits of numerical weather prediction to yield these high-resolution data sets, and wind data will have to be time-synchronized with solar data. Current wind and solar integration data sets are presented. The Wind Integration National Dataset (WIND) Toolkit is the largest and most complete grid integration data set publicly available to date. A meteorological data set, wind power production time series, and simulated forecasts created using the Weather Research and Forecasting Model run on a 2-km grid over the continental United States at a 5-min resolution is now publicly available for more than 126,000 land-based and offshore wind power production sites. The National Solar Radiation Database (NSRDB) is a similar high temporal- and spatial resolution database of 18 years of solar resource data for North America and India. The need for high-resolution weather data pushes modeling towards finer scales and closer synchronization. We also present how we anticipate such datasets developing in the future, their benefits, and the challenges with using and disseminating such large amounts of data.

  8. Design considerations for high-current superconducting ion linacs

    International Nuclear Information System (INIS)

    Delayen, J.R.; Bohn, C.L.; Micklich, B.J.; Roche, C.T.; Sagalovsky, L.

    1993-01-01

    Superconducting linacs may be a viable option for high-current applications such as fusion materials irradiation testing, spallation neutron source, transmutation of radioactive waste, tritium production, and energy production. These linacs must run reliably for many years and allow easy routine maintenance. Superconducting cavities operate efficiently with high cw gradients, properties which help to reduce operating and capital costs, respectively. However, cost-effectiveness is not the sole consideration in these applications. For example, beam impingement must be essentially eliminated to prevent unsafe radioactivation of the accelerating structures, and thus large apertures are needed through which to pass the beam. Because of their high efficiency, superconducting cavities can be designed with very large bore apertures, thereby reducing the effect of beam impingement. Key aspects of high-current cw superconducting linac designs are explored in this context

  9. High-temperature superconducting current leads

    Science.gov (United States)

    Hull, J. R.

    1992-07-01

    The use of high-temperature superconductors (HTSs) for current leads to deliver power to devices at liquid helium temperature is near commercial realization. The use of HTSs in this application has the potential to reduce refrigeration requirements and helium boiloff to values significantly lower than the theoretical best achievable with conventional leads. Considerable advantage is achieved by operating these leads with an intermediate temperature heat sink. The HTS part of the lead can be made from pressed and sintered powder. Powder-in-tube fabrication is also possible, however, the normal metal part of the lead acts as a thermal short and cannot provide much stabilization without increasing the refrigeration required. Lead stability favors designs with low current density. Such leads can be manufactured with today's technology, and lower refrigeration results from the same allowable burnout time. Higher current densities result in lower boiloff for the same lead length, but bumout times can be very short. In comparing experiment to theory, the density of helium vapor needs to be accounted for in calculating the expected boiloff. For very low-loss leads, two-dimensional heat transfer and the state of the dewar near the leads may play a dominant role in lead performance.

  10. Optimization of laser parameters to obtain high-energy, high-quality electron beams through laser-plasma acceleration

    International Nuclear Information System (INIS)

    Samant, Sushil Arun; Sarkar, Deepangkar; Krishnagopal, Srinivas; Upadhyay, Ajay K.; Jha, Pallavi

    2010-01-01

    The propagation of an intense (a 0 =3), short-pulse (L∼λ p ) laser through a homogeneous plasma has been investigated. Using two-dimensional simulations for a 0 =3, the pulse-length and spot-size at three different plasma densities were optimized in order to get a better quality beam in laser wakefield accelerator. The study reveals that with increasing pulse-length the acceleration increases, but after a certain pulse-length (L>0.23λ p ) the emittance blows-up unacceptably. For spot-sizes less than that given by k p0 r s =2√(a 0 ), trapping is poor or nonexistent, and the optimal spot-size is larger. The deviation of the optimal spot-size from this formula increases as the density decreases. The efficacy of these two-dimensional simulations has been validated by running three-dimensional simulations at the highest density. It has been shown that good quality GeV-class beams can be obtained at plasma densities of ∼10 18 cm -3 . The quality of the beam can be substantially improved by selecting only the high-energy peak; in this fashion an energy-spread of better than 1% and a current in tens of kA can be achieved, which are important for applications such as free-electron lasers.

  11. A Portable Low-Cost High Density Sensor Network for Air Quality at London Heathrow Airport

    Science.gov (United States)

    Popoola, Olalekan; Mead, Iq; Bright, Vivien; Baron, Ronan; Saffell, John; Stewart, Gregor; Kaye, Paul; Jones, Roderic

    2013-04-01

    Outdoor air quality and its impact on human health and the environment have been well studied and it has been projected that poor air quality will surpass poor sanitation as the major course of environmental premature mortality by 2050 (IGAC / IGBP, release statement, 2012). Transport-related pollution has been regulated at various levels by enactment of legislations at local, national, regional and global stages. As part of the mitigation measures, routine measurements of atmospheric pollutants such as carbon monoxide (CO), nitric oxide (NO) and nitrogen dioxide (NO2) have to be established in areas where air quality problems are identified. In addition, emission inventories are also generated for different atmospheric environments including urban areas and airport environments required for air quality models. Whilst recognising that most of the existing sparse monitoring networks provide high temporal measurements, spatial data of these highly variable pollutants are not captured, making it difficult to adequately characterise the highly heterogeneous air quality. Spatial information is often obtained from model data which can only be constrained using measurements from the sparse monitoring networks. The work presented here shows the application of low-cost sensor networks aimed at addressing this missing spatial information. We have shown in previous studies the application of low-cost electrochemical sensor network instruments in monitoring road transport pollutants including CO, NO and NO2 in an urban environment (Mead et. al. 2012, accepted Atmospheric Environment). Modified versions of these instruments which include additional species such as O3, SO2, VOCs and CO2 are currently deployed at London Heathrow Airport (LHR) as part of the Sensor Network for Air Quality (SNAQ) project. Meteorology data such as temperature, relative humidity, wind speed and direction are also measured as well as size-speciated particulates (0.38 to 17.4 µm). A network of 50

  12. Bundled Payments in Total Joint Replacement: Keeping Our Care Affordable and High in Quality.

    Science.gov (United States)

    McLawhorn, Alexander S; Buller, Leonard T

    2017-09-01

    The purpose of this review was to evaluate the literature regarding bundle payment reimbursement models for total joint arthroplasty (TJA). From an economic standpoint, TJA are cost-effective, but they represent a substantial expense to the Centers for Medicare & Medicaid Services (CMS). Historically, fee-for-service payment models resulted in highly variable cost and quality. CMS introduced Bundled Payments for Care Improvement (BPCI) in 2012 and subsequently the Comprehensive Care for Joint Replacement (CJR) reimbursement model in 2016 to improve the value of TJA from the perspectives of both CMS and patients, by improving quality via cost control. Early results of bundled payments are promising, but preserving access to care for patients with high comorbidity burdens and those requiring more complex care is a lingering concern. Hospitals, regardless of current participation in bundled payments, should develop care pathways for TJA to maximize efficiency and patient safety.

  13. Fabrication of high quality anodic aluminum oxide (AAO) on low purity aluminum—A comparative study with the AAO produced on high purity aluminum

    International Nuclear Information System (INIS)

    Michalska-Domańska, Marta; Norek, Małgorzata; Stępniowski, Wojciech J.; Budner, Bogusław

    2013-01-01

    Highlights: • Nanoporous alumina was fabricated by anodization in sulfuric acid solution with glycol. • The AAO manufacturing on low- and high-purity Al was compared. • The pores size was ranging between 30 and 50 nm. • No difference in the quality of the AAO fabricated on both Al types was observed. • The current vs. anodization time curves were recorded. -- Abstract: In this work the quality, arrangement, composition, and regularity of nanoporous AAO formed on the low-purity (AA1050) and high-purity aluminum during two-step anodization in a mixture of sulfuric acid solution (0.3 M), water and glycol (3:2, v/v), at various voltages (15, 20, 25, 30, 35 V) and at temperature of −1 °C, are investigated. The electrochemical conditions have allowed to obtain pores with the size ranging from 30 to 50 nm, which are much larger than those usually obtained by anodization in a pure sulfuric acid solution (<20 nm). The mechanism of the AAO growth is discussed. It was found that with the increase of applied anodizing voltage a number of incorporated sulfate ions in the aluminum oxide matrix increases, which was connected with the appearance of an unusual area in the current vs. time curves. On the surface of anodizing low- and high-purity aluminum, the formation of hillocks was observed, which was associated with the sulfate ions incorporation. The sulfate ions are replacing the oxygen atom/atoms in the AAO amorphous crystal structure and, consequently, the AAO template swells, the oxide cracks and uplifts causing the formation of hillocks. The same mechanism occurs for both low- and high-purity aluminum. Nanoporous AAO characterized by a very high regularity, not registered previously for low purity aluminum, was obtained. Furthermore, no significant difference in the regularity ratio between the AAO obtained on low- and high-purity aluminum, was observed. The electrochemical conditions applied in this study can be, thus, used for the fabrication of high quality

  14. Public reporting on quality, waiting times and patient experience in 11 high-income countries

    OpenAIRE

    Rechel, Bernd; McKee, Martin; Haas, Marion; Marchildon, Gregory P; Bousquet, Frederic; Blümel, Miriam; Geissler, Alexander; van Ginneken, Ewout; Ashton, Toni; Saunes, Ingrid Sperre; Anell, Anders; Quentin, Wilm; Saltman, Richard; Culler, Steven; Barnes, Andrew

    2016-01-01

    : This article maps current approaches to public reporting on waiting times, patient experience and aggregate measures of quality and safety in 11 high-income countries (Australia, Canada, England, France, Germany, Netherlands, New Zealand, Norway, Sweden, Switzerland and the United States). Using a questionnaire-based survey of key national informants, we found that the data most commonly made available to the public are on waiting times for hospital treatment, being reported for major hospi...

  15. High-current pulses from inductive energy stores

    International Nuclear Information System (INIS)

    Wipf, S.L.

    1981-01-01

    Superconducting inductive energy stores can be used for high power pulse supplies if a suitable current multiplication scheme is used. The concept of an inductive Marx generator is superior to a transformer. A third scheme, a variable flux linkage device, is suggested; in multiplying current it also compresses energy. Its function is in many ways analogous to that of a horsewhip. Superconductor limits indicate that peak power levels of TW can be reached for stored energies above 1 MJ

  16. High quality data: An evaluation of AIM data quality and data quality procedures

    Science.gov (United States)

    The goal of every monitoring program is to collect high-quality data which can then be used to provide information to decision makers. The Bureau of Land Management (BLM) Assessment, Inventory, and Monitoring (AIM) program is one such data set which provides rangeland status, condition, and trend in...

  17. High current betatron research at the University of New Mexico

    International Nuclear Information System (INIS)

    Humphries, S. Jr.; Len, L.K.

    1987-01-01

    Betatrons are among the simplest of high energy accelerators. Their circuit is equivalent to a step-up transformer; the electron beam forms a multi-turn secondary winding. Circulation of the beam around the flux core allows generation of high energy electrons with relatively small core mass. As with any transformer, a betatron is energy inefficient at low beam current; the energy balance is dominated by core losses. This fact has prompted a continuing investigation of high current betatrons as efficient, compact sources of beta and gamma radiation. A program has been supported at the University of New Mexico by the Office of Naval Research to study the physics of high current electron beams in circular accelerators and to develop practical technology for high power betatrons. Fabrication and assembly of the main ring was completed in January of this year. In contrast to other recent high current betatron experiments the UNM device utilizes a periodic focusing system to contain high current beams during the low energy phase of the acceleration cycle. The reversing cusp fields generated by alternating polarity solenoidal lenses cancel beam drift motions induced by machine errors. In consequence, they have found that the cusp geometry has had significantly better stability properties than a monodirectional toroidal field. In comparison to other minimum-Β geometries such as the Stelllatron cusps have open field lines which facilitate beam injection and neutralization

  18. Critical current densities amd pinning mechanisms of high-Tc films on single crystalline and technologically relevant substrates. Final report

    International Nuclear Information System (INIS)

    Adrian, H.

    1995-12-01

    The report deals with six project tasks: (1) Effects of impurity additions at atomic level on the pinning behaviour and the critical current densities, examined in epitactic YBA 2 (Cu 1-x Ni x ) 3 O 7 films. It could be proven that the Ni atoms increase the activation energy for flux movement and the critical current density in a concentration range of 0 2 Sr 2 Ca n-1 Cu n O 2n+4+δ films (n = 2 and 3) with good crystalline properties, high critical currents, and high current densities were prepared. Thin YBa 2 Cu 3 O 7 films of high quality could be grown on saphire substrates, both by the MO-CVD process and by MBE. The aim of depositing biaxially textured YBa 2 Cu 3 O 7 films with high critical current densities on polycrystalline, metallic substrates was achieved by the IBAD process combined with MBE. The buffer layer was YSZ. Heterostructures of the layer sequence YBa 2 Cu 3 O 7 /CeO 2 /Y 0.3 Pr 0.7 Ba 2 Cu 3 O 7 /YBa 2 Cu 3 O 7 and YBa 2 Cu 3 O 7 /CeO 2 /Au were prepared by laser ablation and sputtering processes, in order to examine Josephson ramp contacts and superconducting field-effect transistors. (orig./MM) [de

  19. Performance of unified power quality conditioner (UPQC) based on fuzzy controller for attenuating of voltage and current harmonics

    Science.gov (United States)

    Milood Almelian, Mohamad; Mohd, Izzeldin I.; Asghaiyer Omran, Mohamed; Ullah Sheikh, Usman

    2018-04-01

    Power quality-related issues such as current and voltage distortions can adversely affect home and industrial appliances. Although several conventional techniques such as the use of passive and active filters have been developed to increase power quality standards, these methods have challenges and are inadequate due to the increasing number of applications. The Unified Power Quality Conditioner (UPQC) is a modern strategy towards correcting the imperfections of voltage and load current supply. A UPQC is a combination of both series and shunt active power filters in a back-to-back manner with a common DC link capacitor. The control of the voltage of the DC link capacitor is important in achieving a desired UPQC performance. In this paper, the UPQC with a Fuzzy logic controller (FLC) was used to precisely eliminate the imperfections of voltage and current harmonics. The results of the simulation studies using MATLAB/Simulink and Simpower system programming for R-L load associated through an uncontrolled bridge rectifier was used to assess the execution process. The UPQC with FLC was simulated for a system with distorted load current and a system with distorted source voltage and load current. The outcome of the comparison of %THD in the load current and source voltage before and after using UPQC for the two cases was presented.

  20. Fast-response protection from high currents

    International Nuclear Information System (INIS)

    Novikov, A.A.

    1989-01-01

    Protection devices for power electronic equipment from shorting current are described. The device is shunted using spark gaps with minimal possible number of spark gaps to protect it. High fast-response (<100 ns) and operation voltage wide range (6-100 kV) are attained using Arkadiev-Marx generator-base trigger devices and air-core pulse transformer

  1. Health-related quality of life in children with high-functioning autism.

    Science.gov (United States)

    Potvin, Marie-Christine; Snider, Laurie; Prelock, Patricia A; Wood-Dauphinee, Sharon; Kehayia, Eva

    2015-01-01

    The health-related quality of life of school-aged children with high-functioning autism is poorly understood. The objectives of this study were to compare the health-related quality of life of children with high-functioning autism to that of typically developing peers and to compare child-self and parent-proxy reports of health-related quality of life of children. A cross-sectional study of children with high-functioning autism (n = 30) and peers (n = 31) was conducted using the Pediatric Quality of Life Inventory 4.0 Generic Core Scales. Children with high-functioning autism had significantly poorer health-related quality of life than peers whether reported by themselves (p children and parental scores suggested variance in points of view. This study specifically investigated health-related quality of life in children with high-functioning autism as compared to a sample of peers, from the child's perspective. It strengthens earlier findings that children with high-functioning autism experience poorer health-related quality of life than those without this disorder and points to the importance of clinicians working with families to identify areas in a child's life that promote or hinder their sense of well-being. © The Author(s) 2013.

  2. Double disordered YBCO coated conductors of industrial scale: high currents in high magnetic field

    International Nuclear Information System (INIS)

    Abraimov, D; Francis, A; Jaroszynski, J; McCallister, J; Polyanskii, A; Santos, M; Viouchkov, Y L; Ballarino, A; Bottura, L; Rossi, L; Barth, C; Senatore, C; Dietrich, R; Rutt, A; Schlenga, K; Usoskin, A; Majkic, G S; Selvamanickam, V

    2015-01-01

    A significant increase of critical current in high magnetic field, up to 31 T, was recorded in long tapes manufactured by employing a double-disorder route. In a double-disordered high-temperature superconductor (HTS), a superimposing of intrinsic and extrinsic disorder takes place in a way that (i) the intrinsic disorder is caused by local stoichiometry deviations that lead to defects of crystallinity that serve as pining centers in the YBa 2 Cu 3 O x−δ matrix and (ii) the extrinsic disorder is introduced via embedded atoms or particles of foreign material (e.g. barium zirconate), which create a set of lattice defects. We analyzed possible technological reasons for this current gain. The properties of these tapes over a wider field-temperature range as well as field anisotropy were also studied. Record values of critical current as high as 309 A at 31 T, 500 A at 18 Tm and 1200 A at 5 T were found in 4 mm wide tape at 4.2 K and B perpendicular to tape surface. HTS layers were processed in medium-scale equipment that allows a maximum batch length of 250 m while 22 m long batches were provided for investigation. Abnormally high ratios (up to 10) of critical current density measured at 4.2 K, 19 T to critical current density measured at 77 K, self-field were observed in tapes with the highest in-field critical current. Anisotropy of the critical current as well as angular dependences of n and α values were investigated. The temperature dependence of critical current is presented for temperatures between 4.2 and 40 K. Prospects for the suppression of the dog-bone effect by Cu plating and upscale of processing chain to >500 m piece length are discussed. (paper)

  3. Double disordered YBCO coated conductors of industrial scale: high currents in high magnetic field

    Science.gov (United States)

    Abraimov, D.; Ballarino, A.; Barth, C.; Bottura, L.; Dietrich, R.; Francis, A.; Jaroszynski, J.; Majkic, G. S.; McCallister, J.; Polyanskii, A.; Rossi, L.; Rutt, A.; Santos, M.; Schlenga, K.; Selvamanickam, V.; Senatore, C.; Usoskin, A.; Viouchkov, Y. L.

    2015-11-01

    A significant increase of critical current in high magnetic field, up to 31 T, was recorded in long tapes manufactured by employing a double-disorder route. In a double-disordered high-temperature superconductor (HTS), a superimposing of intrinsic and extrinsic disorder takes place in a way that (i) the intrinsic disorder is caused by local stoichiometry deviations that lead to defects of crystallinity that serve as pining centers in the YBa2Cu3O x-δ matrix and (ii) the extrinsic disorder is introduced via embedded atoms or particles of foreign material (e.g. barium zirconate), which create a set of lattice defects. We analyzed possible technological reasons for this current gain. The properties of these tapes over a wider field-temperature range as well as field anisotropy were also studied. Record values of critical current as high as 309 A at 31 T, 500 A at 18 Tm and 1200 A at 5 T were found in 4 mm wide tape at 4.2 K and B perpendicular to tape surface. HTS layers were processed in medium-scale equipment that allows a maximum batch length of 250 m while 22 m long batches were provided for investigation. Abnormally high ratios (up to 10) of critical current density measured at 4.2 K, 19 T to critical current density measured at 77 K, self-field were observed in tapes with the highest in-field critical current. Anisotropy of the critical current as well as angular dependences of n and α values were investigated. The temperature dependence of critical current is presented for temperatures between 4.2 and 40 K. Prospects for the suppression of the dog-bone effect by Cu plating and upscale of processing chain to >500 m piece length are discussed.

  4. Image Quality in High-resolution and High-cadence Solar Imaging

    Science.gov (United States)

    Denker, C.; Dineva, E.; Balthasar, H.; Verma, M.; Kuckein, C.; Diercke, A.; González Manrique, S. J.

    2018-03-01

    Broad-band imaging and even imaging with a moderate bandpass (about 1 nm) provides a photon-rich environment, where frame selection (lucky imaging) becomes a helpful tool in image restoration, allowing us to perform a cost-benefit analysis on how to design observing sequences for imaging with high spatial resolution in combination with real-time correction provided by an adaptive optics (AO) system. This study presents high-cadence (160 Hz) G-band and blue continuum image sequences obtained with the High-resolution Fast Imager (HiFI) at the 1.5-meter GREGOR solar telescope, where the speckle-masking technique is used to restore images with nearly diffraction-limited resolution. The HiFI employs two synchronized large-format and high-cadence sCMOS detectors. The median filter gradient similarity (MFGS) image-quality metric is applied, among others, to AO-corrected image sequences of a pore and a small sunspot observed on 2017 June 4 and 5. A small region of interest, which was selected for fast-imaging performance, covered these contrast-rich features and their neighborhood, which were part of Active Region NOAA 12661. Modifications of the MFGS algorithm uncover the field- and structure-dependency of this image-quality metric. However, MFGS still remains a good choice for determining image quality without a priori knowledge, which is an important characteristic when classifying the huge number of high-resolution images contained in data archives. In addition, this investigation demonstrates that a fast cadence and millisecond exposure times are still insufficient to reach the coherence time of daytime seeing. Nonetheless, the analysis shows that data acquisition rates exceeding 50 Hz are required to capture a substantial fraction of the best seeing moments, significantly boosting the performance of post-facto image restoration.

  5. Rapid Measurement and Correction of Phase Errors from B0 Eddy Currents: Impact on Image Quality for Non-Cartesian Imaging

    Science.gov (United States)

    Brodsky, Ethan K.; Klaers, Jessica L.; Samsonov, Alexey A.; Kijowski, Richard; Block, Walter F.

    2014-01-01

    Non-Cartesian imaging sequences and navigational methods can be more sensitive to scanner imperfections that have little impact on conventional clinical sequences, an issue which has repeatedly complicated the commercialization of these techniques by frustrating transitions to multi-center evaluations. One such imperfection is phase errors caused by resonant frequency shifts from eddy currents induced in the cryostat by time-varying gradients, a phenomemon known as B0 eddy currents. These phase errors can have a substantial impact on sequences that use ramp sampling, bipolar gradients, and readouts at varying azimuthal angles. We present a method for measuring and correcting phase errors from B0 eddy currents and examine the results on two different scanner models. This technique yields significant improvements in image quality for high-resolution joint imaging on certain scanners. The results suggest that correction of short time B0 eddy currents in manufacturer provided service routines would simplify adoption of non-Cartesian sampling methods. PMID:22488532

  6. Summarized Costs, Placement Of Quality Stars, And Other Online Displays Can Help Consumers Select High-Value Health Plans.

    Science.gov (United States)

    Greene, Jessica; Hibbard, Judith H; Sacks, Rebecca M

    2016-04-01

    Starting in 2017, all state and federal health insurance exchanges will present quality data on health plans in addition to cost information. We analyzed variations in the current design of information on state exchanges to identify presentation approaches that encourage consumers to take quality as well as cost into account when selecting a health plan. Using an online sample of 1,025 adults, we randomly assigned participants to view the same comparative information on health plans, displayed in different ways. We found that consumers were much more likely to select a high-value plan when cost information was summarized instead of detailed, when quality stars were displayed adjacent to cost information, when consumers understood that quality stars signified the quality of medical care, and when high-value plans were highlighted with a check mark or blue ribbon. These approaches, which were equally effective for participants with higher and lower numeracy, can inform the development of future displays of plan information in the exchanges. Project HOPE—The People-to-People Health Foundation, Inc.

  7. Impact of wood burning on outdoor air quality: existing French data and current studies

    International Nuclear Information System (INIS)

    Leoz-Garziandia, E.; Mandin, C.; Collet, S.; Besombes, J.L.; Pissot, N.; Allemand, N.; Riberon, J.; Jaffrezo, J.L.

    2009-01-01

    French source apportionment studies of air quality including the wood combustion source become widespread. Quantify a single source contribution to air quality requires to be provided with a specific measurable data to this source. For that reason, numerous studies have focused on the determination, in the atmospheric samples, of the source-specific compounds, usually called molecular tracers. Since 2000, trend works focused on the 'wood combustion' contribution to air quality have been based on the use of some tracers such as levoglucosan and metoxyphenols. Obtained results have been compared to atmospheric particles global characteristics: organic carbon (OC), elementary carbon (EC), PM 10 , PM 2.5 and polycyclic aromatic hydrocarbons (PAH). The results presented in this article show not only the interest but also the limits of such an approach, as well as the need to develop and complete the current studies in order to quantify the different sources contribution to air quality. (author)

  8. [Psychiatric comorbidities and quality of life in adult individuals with high potential: Relationships with self-esteem].

    Science.gov (United States)

    Lancon, Christophe; Martinelli, Marion; Michel, Pierre; Debals, Matthias; Auquier, Pascal; Guedj, Eric; Boyer, Laurent

    2015-05-01

    The objectives of this study were: 1) to describe the psychiatric comorbidities in adult individuals with high potential; 2) to assess self-esteem and quality of life in comparison with general population; 3) to study the relationships between intelligent quotient (IQ), self-esteem, psychiatric comorbidities and quality of life. This cross-sectional study was conducted in the psychiatric department of a public university hospital (Marseille, France). An outpatient hospital service has been specifically opened to test intelligence since 2012. During a period of six months, it was proposed to all the major individuals with high intellectual potential to receive a psychiatric evaluation using the Mini International Neuropsychiatric Interview (MINI) and to complete self-report questionnaires assessing depression (Beck scale), anxiety (STAI), self-esteem (Rosenberg scale) and quality of life (SF-36). Relationships between IQ, self-esteem, psychiatric comorbidities and quality of life were analyzed using a Bayesian path analysis. Twenty-eight subjects were included, 8 had an IQ between 115 and 130, and 20 had an IQ>130. Fifty-seven percent of individuals had generalized anxiety, 21.4% a current major depressive episode, and 75% a past major depressive episode. Subjects had a low self-esteem and quality of life levels significantly lower than those in the French general population. Subjects with higher self-esteem levels had more depressive (β=0.726, Pself-esteem was defensive and inadequate. Our study found a high frequency of psychiatric disorders associated with low levels of self-esteem and quality of life. A psychological treatment focusing on self-esteem may have a beneficial effect on anxiety, depression and quality of life. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  9. High-dose irradiated food: Current progress, applications, and prospects

    Science.gov (United States)

    Feliciano, Chitho P.

    2018-03-01

    Food irradiation as an established and mature technology has gained more attention in the food industry for ensuring food safety and quality. Primarily used for phytosanitary applications, its use has been expanded for developing various food products for varied purposes (e.g. ready-to-eat & ready-to-cook foods, hospital diets, etc.). This paper summarized and analyzed the recent progress and application of high-dose irradiation and discussed its prospects in the field of food product development, its safety and quality.

  10. Microstructures and critical currents in high-Tc superconductors

    International Nuclear Information System (INIS)

    Suenaga, Masaki

    1998-01-01

    Microstructural defects are the primary determining factors for the values of critical-current densities in a high T c superconductor after the electronic anisotropy along the a-b plane and the c-direction. A review is made to assess firstly what would be the maximum achievable critical-current density in YBa 2 Cu 3 O 7 if nearly ideal pinning sites were introduced and secondly what types of pinning defects are currently introduced or exist in YBa 2 Cu 3 O 7 and how effective are these in pinning vortices

  11. [Current quality management situation and administration countermeasure study of enterprises marketing corneal contact lens].

    Science.gov (United States)

    Liu, Yungui; Yao, Ying; Shangguan, Shihao; Gu, Qun; Gao, Wuming; Chen, Yaoshui

    2014-05-01

    Study the current quality management situation of enterprises marketing corneal contact lens via systemic investigations and explore effective administration countermeasures in the future. The quality management indicators of sixty-two corneal contact lens marketing enterprises in Xuhui district of Shanghai were systematically investigated and enterprises of different operation models was compared and analyzed. Wholesale enterprises and retail chain enterprises are apparently better than independent enterprises almost in all facets. Facilitate market accession of corneal contact lens marketing enterprises, encourage the business model of retail chain, enhance supervision of corneal contact lens marketing enterprises, especially independent franchisors.

  12. Comparison on Heat of Hydration between Current Concrete for NPP and High Fluidity Concrete including Pozzolan Powders

    International Nuclear Information System (INIS)

    Noh, Jea Myoung; Cho, Myung Sug

    2010-01-01

    Nuclear power plant (NPP) concrete structures are exposed to many construction factors that lower the quality of concrete due to densely packed reinforcements and heat of hydration since they are mostly constructed with mass concrete. The concrete currently being used in Korean NPPs is mixed with Type I cement and fly ash. However, there is a demand to improve the performance of concrete with reduced heat of hydration and superior constructability. Many advantages such as improving workability and durability of concrete and decreasing heat of hydration are introduced by replacing cement with pozzolan binders. Therefore, the manufacturing possibility of high fluidity concrete should be investigated through applying multi-component powders blended with pozzolan binders to the concrete structure of NPPs, while the researches on properties, characteristic of hydration, durability and long-term behavior of high fluidity concrete using multi-component cement should be carried out. High fluidity concrete which is made using portland cement and pozzlonan powders such as fly ash and blast furnace slag has better properties on heat of hydration than the concrete currently in use for NPPs

  13. Subjective and Objective Assessment of Perceived Audio Quality of Current Digital Audio Broadcasting Systems and Web-Casting Applications

    NARCIS (Netherlands)

    Pocta, P.; Beerends, J.G.

    2015-01-01

    This paper investigates the impact of different audio codecs typically deployed in current digital audio broadcasting (DAB) systems and web-casting applications, which represent a main source of quality impairment in these systems and applications, on the quality perceived by the end user. Both

  14. Characterization of a high-power/current pulsed magnetized arc discharge

    NARCIS (Netherlands)

    Zielinski, J. J.; van der Meiden, H. J.; Morgan, T. W.; D.C. Schram,; De Temmerman, G.

    2012-01-01

    A high-power pulsed magnetized arc discharge has been developed to allow the superimposition of a dc plasma and a high-power plasma impulse with a single plasma source. A capacitor bank (8400 mu F) is parallel-coupled to the current regulated power supply. The current is transiently increased from

  15. Characterization of a high-power/current pulsed magnetized arc discharge

    NARCIS (Netherlands)

    Zielinski, J.J.; Meiden, van der H.J.; Morgan, T.W.; Schram, D.C.; De Temmerman, G.C.

    2012-01-01

    A high-power pulsed magnetized arc discharge has been developed to allow the superimposition of a dc plasma and a high-power plasma impulse with a single plasma source. A capacitor bank (8400 µF) is parallel-coupled to the current regulated power supply. The current is transiently increased from its

  16. High quality uniform YBCO film growth by the metalorganic deposition using trifluoroacetates

    Energy Technology Data Exchange (ETDEWEB)

    Wang, S.S., E-mail: wangssh@tsinghua.edu.cn [Key Laboratory of Micro-nano Measurement, Manipulation and Physics (Beihang University), Ministry of Education, Beijing 100191 (China); Beijing Dingchen Superconducting Technology Co., Ltd., Beijing 100084 (China); Zhang, Z.L. [Key Laboratory of Micro-nano Measurement, Manipulation and Physics (Beihang University), Ministry of Education, Beijing 100191 (China); Wang, L. [Applied superconductivity research center, Department of Physics, Tsinghua University, Beijing 100084 (China); Gao, L.K.; Liu, J. [Beijing Dingchen Superconducting Technology Co., Ltd., Beijing 100084 (China)

    2017-03-15

    Highlights: • High quality double-sided YBCO films are fabricated on LaAlO3 substrates by TFA-MOD method with diameters up to 2 in. • Large area YBCO films were very uniform in microstructure and thickness distribution, an average inductive Jc in excess of 6 MA/cm{sup 2} and low R{sub s} (10 GHz) of 0.3 mΩ at 77 K were obtained. • It will greatly promoted the research and applications of large-area YBCO films by chemical solution method. - Abstract: A need exists for the large-area superconducting YBa{sub 2}Cu{sub 3}O{sub 7-x} (YBCO) films with high critical current density for microwave communication and/or electric power applications. Trifluoroacetic metalorganic (TFA-MOD) method is a promising low cost technique for large-scale production of YBCO films, because it does not need high vacuum device and is easily applicable to substrates of various shape and size. In this paper, double-sided YBCO films with maximum 2 in diameter were prepared on LaAlO{sub 3} substrates by TFA-MOD method. Inductive critical current densitiy J{sub c}, microwave surface resistance R{sub s}, as well as the microstructure were characterized. A newly homemade furnace system was used to epitaxially grown YBCO films, which can improve the uniformity of YBCO film significantly by gas supply and temperature distribution proper design. Results showed that the large area YBCO films were very uniform in microstructure and thickness distribution, an average inductive J{sub c} in excess of 6 MA/cm{sup 2} with uniform distribution, and low R{sub s} (10 GHz) below 0.3 mΩ at 77 K were obtained. Andthe film filter may be prepared to work at temperatures lower than 74 K. These results are very close to the highest value of YBCO films made by conventional vacuum method, so we show a very promising route for large-scale production of high quality large-area YBCO superconducting films at a lower cost.

  17. Development of high electrical resistance persistent current switch for high speed energization system

    International Nuclear Information System (INIS)

    Jizo, Y.; Furuta, Y.; Nakashima, H.

    1986-01-01

    Japanese National Railways is now developing a superconducting magnetically-levitated train system. A persistent current switch is incorporated in the super-conducting magnet used in the magnetically-levitated train. In recent years, the switch has been required to have higher electrical resistance during its off-state in order to realize the high speed energization/de-energization system of the superconducting magnets. The system aims to decrease evaporation volume of liquid helium during the energization/de-energization of the magnet, by means of energizing the superconducting magnet with high current increasing/decreasing rate. Consequently, it would be possible to decrease the dependence of the on-board magnet system upon the ground cooling system. Through the development of a stable superconductive wire material and a coil structure for the persistent current switch using many small model switches which were produced in order to improve their current carrying capacities, the authors have succeeded in manufacturing the high electrical resistance persistent current switch whose electrical resistance was 5 ohms. The switch, of cylindrical shape, has a diameter of about 100mm, a length of about 100mm. These 5 ohm PCSs are now functioning in stable conditions being incorporated in the superconducting magnets of No.2 vehicle of MLU001 at the JNR's Miyazaki test track. Further, the authors are now developing the PCS of still higher resistance values, such as 50 ohms, through studies for stabilization in structural aspects of the winding and obtaining results therefrom

  18. Real-World Solutions for Developing High-Quality PHP Frameworks and Applications

    CERN Document Server

    Bergmann, Sebastian

    2011-01-01

    Learn to develop high-quality applications and frameworks in PHP Packed with in-depth information and step-by-step guidance, this book escorts you through the process of creating, maintaining and extending sustainable software of high quality with PHP. World-renowned PHP experts present real-world case studies for developing high-quality applications and frameworks in PHP that can easily be adapted to changing business requirements. . They offer different approaches to solving  typical development and quality assurance problems that every developer needs to know and master.Details the process

  19. High-speed radiography and x-ray cinematography by high-current betatrons

    International Nuclear Information System (INIS)

    Akimochkin, Yu.V.; Akulov, G.V.; Leunov, F.G.; Moskalev, V.A.; Ryabukhin, V.L.

    1979-01-01

    The paper provides a description of an equipment system comprising a pair of 25 MeV high-current betatrons and an X-ray drum-type cinecamera for high-speed radiography and X-ray cinematography for use when studying dynamics of objects moving at a rate of 0.5 - 3.0 km/s as well as in X-ray cinematography of processes at a rate of up to 1 m/s. (author)

  20. CONSIDERATIONS REGARDING THE 21st CENTURY’s HIGH QUALITY SECURITY CONCEPT

    Directory of Open Access Journals (Sweden)

    Eugen SITEANU

    2017-12-01

    Full Text Available The present paper is devoted to qualitative security which today has to become a topic issue of world security. The opinions regarding the 21st century’s security concept are contradictory since people have different understandings and perceptions of security, respectively insecurity, and do not agree to analyze the security concept as a function of the system. Our take is that implementation of some new security concepts should aim an analysis and understanding of security in an integrating view, in order to make the most comprehensive security environment possible. Therefore, we do believe that it is necessary to define the concept of high quality security, which is translated in our current paper.

  1. 2000W high beam quality diode laser for direct materials processing

    Science.gov (United States)

    Qin, Wen-bin; Liu, You-qiang; Cao, Yin-hua; Gao, Jing; Pan, Fei; Wang, Zhi-yong

    2011-11-01

    This article describes high beam quality and kilowatt-class diode laser system for direct materials processing, using optical design software ZEMAX® to simulate the diode laser optical path, including the beam shaping, collimation, coupling, focus, etc.. In the experiment, the diode laser stack of 808nm and the diode laser stack of 915nm were used for the wavelength coupling, which were built vertical stacks up to 16 bars. The threshold current of the stack is 6.4A, the operating current is 85A and the output power is 1280W. Through experiments, after collimating the diode laser beam with micro-lenses, the fast axis BPP of the stack is less than 60mm.mrad, and the slow-axis BPP of the stack is less than 75mm.mrad. After shaping the laser beam and improving the beam quality, the fast axis BPP of the stack is still 60mm.mrad, and the slow-axis BPP of the stack is less than 19mm.mrad. After wavelength coupling and focusing, ultimately the power of 2150W was obtained, focal spot size of 1.5mm * 1.2mm with focal length 300mm. The laser power density is 1.2×105W/cm2, and that can be used for metal remelting, alloying, cladding and welding. The total optical coupling conversion efficiency is 84%, and the total electrical - optical conversion efficiency is 50%.

  2. High Field Side Lower Hybrid Current Drive Simulations for Off- axis Current Drive in DIII-D

    Directory of Open Access Journals (Sweden)

    Wukitch S.J.

    2017-01-01

    Full Text Available Efficient off-axis current drive scalable to reactors is a key enabling technology for developing economical, steady state tokamak. Previous studies have focussed on high field side (HFS launch of lower hybrid current drive (LHCD in double null configurations in reactor grade plasmas and found improved wave penetration and high current drive efficiency with driven current profile peaked near a normalized radius, ρ, of 0.6-0.8, consistent with advanced tokamak scenarios. Further, HFS launch potentially mitigates plasma material interaction and coupling issues. For this work, we sought credible HFS LHCD scenario for DIII-D advanced tokamak discharges through utilizing advanced ray tracing and Fokker Planck simulation tools (GENRAY+CQL3D constrained by experimental considerations. For a model and existing discharge, HFS LHCD scenarios with excellent wave penetration and current drive were identified. The LHCD is peaked off axis, ρ∼0.6-0.8, with FWHM Δρ=0.2 and driven current up to 0.37 MA/MW coupled. For HFS near mid plane launch, wave penetration is excellent and have access to single pass absorption scenarios for variety of plasmas for n||=2.6-3.4. These DIII-D discharge simulations indicate that HFS LHCD has potential to demonstrate efficient off axis current drive and current profile control in DIII-D existing and model discharge.

  3. Thinking of English Quality Education

    Institute of Scientific and Technical Information of China (English)

    袁捷

    2012-01-01

    On the suggestions of advancing quality-oriented education actively, the State Education Commission made detailed explanation to Chinese quality education: Quality Education is education taking improv- ing whole nation’s quality as its aim. With the high-speed development of economy, quality education, especially English quality education, is out of line from development in our country. Thus, based on the current situation of English Quality Education, it deserves our attention of Secondary Vocational English Quality Education on English quality, English quality education, principles and strategies.

  4. Health-related quality of life in current smokers with COPD: factors associated with current smoking and new insights into sex differences

    Directory of Open Access Journals (Sweden)

    Cheruvu VK

    2016-09-01

    Full Text Available Vinay K Cheruvu,1 Lorriane A Odhiambo,1 Dana S Mowls,2 Melissa D Zullo,1 Abdi T Gudina1 1Department of Biostatistics, Environmental Health Sciences, and Epidemiology, College of Public Health, Kent State University, Kent, OH, 2Department of Biostatistics & Epidemiology, College of Public Health, University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA Abstract: Findings from studies that examined the association between health-related ­quality of life (HRQOL and smoking status among COPD patients have been mixed. Moreover, factors associated with current smoking in COPD patients and differences by sex have not been fully elucidated. Data from the 2011 and 2012 Behavioral Risk Factor Surveillance System was used in this study. Four HRQOL indicators were examined in this study: general health, physical health, mental health, and activity limitations. General health was dichotomized into two groups: “excellent/very good/good” and “fair/poor”, and the other three HRQOL indicators were dichotomized into <14 (infrequent and ≥14 (frequent unhealthy days in the past 30 days. To examine HRQOL indicators in association with current versus former smoking and identify factors associated with current smoking, logistic regression models were used. Sex differences were explored. In COPD patients, current smokers compared to former smokers had significantly poor HRQOL on all subdomains: “fair/poor” general health (adjusted odds ratio [AOR]: 1.2 [95% confidence interval {CI}: 1.1–1.5]; poor physical health (AOR: 1.3 [CI: 1.1–1.5]; poor mental health (AOR: 1.8 [CI: 1.4–2.2]; and poor activity limitations (AOR: 1.5 [CI: 1.3–1.9]. HRQOL subdomains affected by current smoking differed by sex except activity limitations. General health (AOR: 1.5 [CI: 1.1–2.0] and activity limitations (AOR: 1.6 [95% CI: 1.2–2.2] in males and physical health (AOR: 1.3 [CI: 1.0–1.6], mental health (AOR: 2.1 [CI: 1.7–2.6], and activity

  5. Prodigious Effects of Concentration Intensification on Nanoparticle Synthesis: A High-Quality, Scalable Approach

    KAUST Repository

    Williamson, Curtis B.

    2015-12-23

    © 2015 American Chemical Society. Realizing the promise of nanoparticle-based technologies demands more efficient, robust synthesis methods (i.e., process intensification) that consistently produce large quantities of high-quality nanoparticles (NPs). We explored NP synthesis via the heat-up method in a regime of previously unexplored high concentrations near the solubility limit of the precursors. We discovered that in this highly concentrated and viscous regime the NP synthesis parameters are less sensitive to experimental variability and thereby provide a robust, scalable, and size-focusing NP synthesis. Specifically, we synthesize high-quality metal sulfide NPs (<7% relative standard deviation for Cu2-xS and CdS), and demonstrate a 10-1000-fold increase in Cu2-xS NP production (>200 g) relative to the current field of large-scale (0.1-5 g yields) and laboratory-scale (<0.1 g) efforts. Compared to conventional synthesis methods (hot injection with dilute precursor concentration) characterized by rapid growth and low yield, our highly concentrated NP system supplies remarkably controlled growth rates and a 10-fold increase in NP volumetric production capacity (86 g/L). The controlled growth, high yield, and robust nature of highly concentrated solutions can facilitate large-scale nanomanufacturing of NPs by relaxing the synthesis requirements to achieve monodisperse products. Mechanistically, our investigation of the thermal and rheological properties and growth rates reveals that this high concentration regime has reduced mass diffusion (a 5-fold increase in solution viscosity), is stable to thermal perturbations (64% increase in heat capacity), and is resistant to Ostwald ripening.

  6. High Current Planar Transformer for Very High Efficiency Isolated Boost DC-DC Converters

    DEFF Research Database (Denmark)

    Pittini, Riccardo; Zhang, Zhe; Andersen, Michael A. E.

    2014-01-01

    This paper presents a design and optimization of a high current planar transformer for very high efficiency dc-dc isolated boost converters. The analysis considers different winding arrangements, including very high copper thickness windings. The analysis is focused on the winding ac-resistance a......This paper presents a design and optimization of a high current planar transformer for very high efficiency dc-dc isolated boost converters. The analysis considers different winding arrangements, including very high copper thickness windings. The analysis is focused on the winding ac......-resistance and transformer leakage inductance. Design and optimization procedures are validated based on an experimental prototype of a 6 kW dcdc isolated full bridge boost converter developed on fully planar magnetics. The prototype is rated at 30-80 V 0-80 A on the low voltage side and 700-800 V on the high voltage side...... with a peak efficiency of 97.8% at 80 V 3.5 kW. Results highlights that thick copper windings can provide good performance at low switching frequencies due to the high transformer filling factor. PCB windings can also provide very high efficiency if stacked in parallel utilizing the transformer winding window...

  7. Monitoring urban air quality using a high-density network of low-cost sensor nodes in Oslo, Norway.

    Science.gov (United States)

    Castell, Nuria; Schneider, Philipp; Vogt, Matthias; Dauge, Franck R.; Lahoz, William; Bartonova, Alena

    2017-04-01

    Urban air quality represents a major public health burden and is a long-standing concern to citizens. Air pollution is associated with a range of diseases, symptoms and conditions that impair health and quality of life. In Oslo, traffic, especially exhaust from heavy-duty and private diesel vehicles and dust resuspension from studded tyres, together with wood burning in winter, are the main sources of pollution. Norway, as part of the European Economic Area, is obliged to comply with the European air quality regulations and ensure clean air. Despite this, Oslo has exceeded both the NO2 and PM10 thresholds for health protection defined in the Directive 2008/50/EC. The air quality in the Oslo area is continuously monitored in 12 compliance monitoring stations. These stations provide reliable and accurate data but their density is too low to provide a detailed spatial distribution of air quality. The emergence of low-cost nodes enables observations at high spatial resolution, providing the opportunity to enhance existing monitoring systems. However, the data generated by these nodes is significantly less accurate and precise than the data provided by reference equipment. We have conducted an evaluation of low-cost nodes to monitor NO2 and PM10, comparing the data collected with low-cost nodes against CEN (European Standardization Organization) reference analysers. During January and March 2016, a network of 24 nodes was deployed in Oslo. During January, high NO2 levels were observed for several days in a row coinciding with the formation of a thermal inversion. During March, we observed an episode with high PM10 levels due to road dust resuspension. Our results show that there is a major technical challenge associated with current commercial low-cost sensors, regarding the sensor robustness and measurement repeatability. Despite this, low-cost sensor nodes are able to reproduce the NO2 and PM10 variability. The data from the sensors was employed to generate detailed

  8. Low energy current accumulator for high-energy proton rings

    International Nuclear Information System (INIS)

    Month, M.

    1977-01-01

    Building current in high-energy p-p colliding beam machines is most appropriately done in a low-energy (small circumference) current accumulator. Three significant factors favor such a procedure: First, large rings tend to be susceptible to unstable longitudinal density oscillations. These can be avoided by pumping up the beam in the accumulator. When the current stack is injected into the storage ring, potentially harmful instability is essentially neutralized. Second, high-field magnets characteristic of future high energy proton rings are designed with superconducting coils within the iron magnetic shield. This means coil construction and placement errors propagate rapidly within the beam aperture. An intermediate ''stacking ring'' allows the minimum use of the superconducting ring aperture. Finally, the coils are vulnerable to radiation heating and possible magnet quenching. By minimizing beam manipulaion in the superconducting environment and using only the central portion of the beam aperture, coil vulnerability can be put at a minimum

  9. Dominant male song performance reflects current immune state in a cooperatively breeding songbird

    NARCIS (Netherlands)

    York, Jenny E.; Radford, Andrew N.; Groothuis, Ton G.; Young, Andrew J.

    Conspicuous displays are thought to have evolved as signals of individual quality, though precisely what they encode remains a focus of debate. While high quality signals may be produced by high quality individuals due to good genes or favourable early-life conditions, whether current immune state

  10. Hall probe for measuring high currents in superconducting coils

    International Nuclear Information System (INIS)

    Ferendeci, A.M.

    1986-01-01

    Constructional details of a compact Hall probe for measuring high currents in superconducting coils are given. The Hall probe is easy to assemble and can be inserted or removed from the system without breaking the superconducting loop. Upper current limit of the probe can be increased by using larger magnetic core material. Shielding becomes necessary if the probe holder is to be placed near large current dependent magnetic fields

  11. Adaptation of superconducting fault current limiter to high-speed reclosing

    International Nuclear Information System (INIS)

    Koyama, T.; Yanabu, S.

    2009-01-01

    Using a high temperature superconductor, we constructed and tested a model superconducting fault current limiter (SFCL). The superconductor might break in some cases because of its excessive generation of heat. Therefore, it is desirable to interrupt early the current that flows to superconductor. So, we proposed the SFCL using an electromagnetic repulsion switch which is composed of a superconductor, a vacuum interrupter and a by-pass coil, and its structure is simple. Duration that the current flow in the superconductor can be easily minimized to the level of less than 0.5 cycle using this equipment. On the other hand, the fault current is also easily limited by large reactance of the parallel coil. There is duty of high-speed reclosing after interrupting fault current in the electric power system. After the fault current is interrupted, the back-up breaker is re-closed within 350 ms. So, the electromagnetic repulsion switch should return to former state and the superconductor should be recovered to superconducting state before high-speed reclosing. Then, we proposed the SFCL using an electromagnetic repulsion switch which employs our new reclosing function. We also studied recovery time of the superconductor, because superconductor should be recovered to superconducting state within 350 ms. In this paper, the recovery time characteristics of the superconducting wire were investigated. Also, we combined the superconductor with the electromagnetic repulsion switch, and we did performance test. As a result, a high-speed reclosing within 350 ms was proven to be possible.

  12. High performance current controller for particle accelerator magnets supply

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Bidoggia, Benoit; Munk-Nielsen, Stig

    2013-01-01

    The electromagnets in modern particle accelerators require high performance power supply whose output is required to track the current reference with a very high accuracy (down to 50 ppm). This demands very high bandwidth controller design. A converter based on buck converter topology is used...

  13. Security of attachment and quality of mother-toddler social interaction in a high-risk sample.

    Science.gov (United States)

    Haltigan, John D; Lambert, Brittany L; Seifer, Ronald; Ekas, Naomi V; Bauer, Charles R; Messinger, Daniel S

    2012-02-01

    The quality of children's social interactions and their attachment security with a primary caregiver are two widely studied indices of socioemotional functioning in early childhood. Although both Bowlby and Ainsworth suggested that the parent-child interactions underlying the development of attachment security could be distinguished from other aspects of parent-child interaction (e.g., play), relatively little empirical research has examined this proposition. The aim of the current study was to explore this issue by examining concurrent relations between toddler's attachment security in the Strange Situation Procedure and quality of mother-child social interaction in a high-risk sample of toddlers characterized by prenatal cocaine exposure and low levels of maternal education. Analyses of variance suggested limited relations between attachment security and quality of social interaction. Further research examining the interrelations among various components of the parent-child relationship is needed. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Valley current characterization of high current density resonant tunnelling diodes for terahertz-wave applications

    Science.gov (United States)

    Jacobs, K. J. P.; Stevens, B. J.; Baba, R.; Wada, O.; Mukai, T.; Hogg, R. A.

    2017-10-01

    We report valley current characterisation of high current density InGaAs/AlAs/InP resonant tunnelling diodes (RTDs) grown by metal-organic vapour phase epitaxy (MOVPE) for THz emission, with a view to investigate the origin of the valley current and optimize device performance. By applying a dual-pass fabrication technique, we are able to measure the RTD I-V characteristic for different perimeter/area ratios, which uniquely allows us to investigate the contribution of leakage current to the valley current and its effect on the PVCR from a single device. Temperature dependent (20 - 300 K) characteristics for a device are critically analysed and the effect of temperature on the maximum extractable power (PMAX) and the negative differential conductance (NDC) of the device is investigated. By performing theoretical modelling, we are able to explore the effect of typical variations in structural composition during the growth process on the tunnelling properties of the device, and hence the device performance.

  15. Electron gun for formation of two high-current beams

    International Nuclear Information System (INIS)

    Borisov, A.R.; Zherlitsyn, A.G.; Mel'nikov, G.V.; Shtejn, Yu.G.

    1982-01-01

    The design of the ''Tonus'' accelerator electron gun for formation of two high-current beams aiming at the production of the maximum beam power and density is described. The results of investigation of two modes of beam formation are presented. In the first variant the beams were produced by means of two plane diodes with 40 mm diameter cathodes made of stainless steel and anodes made of 50 μm thick titanium foil. In the second variant the beams were formed by means of two coaxial diodes with magnetic insulation. In one diode the cathode diameter equals to 74 mm, the anode diameter - 92 mm, in the other diode 16 and 44 mm respectively. Current redistribution in the diodes and its effect on accelerating voltage are investigated. It is shown that the gun permits formation of synchronized two high-current beams, iaving equal electron energied. Wide range current control of both beams is possible

  16. High Spectral Resolution LIDAR as a Tool for Air Quality Research

    Science.gov (United States)

    Eloranta, E. W.; Spuler, S.; Hayman, M. M.

    2017-12-01

    Many aspects of air quality research require information on the vertical distribution of pollution. Traditional measurements, obtained from surface based samplers, or passive satellite remote sensing, do not provide vertical profiles. Lidar can provide profiles of aerosol properties. However traditional backscatter lidar suffers from uncertain calibrations with poorly constrained algorithms. These problems are avoided using High Spectral Resolution Lidar (HSRL) which provides absolutely calibrated vertical profiles of aerosol properties. The University of Wisconsin HSRL systems measure 532 nm wavelength aerosol backscatter cross-sections, extinction cross-sections, depolarization, and attenuated 1064 nm backscatter. These instruments are designed for long-term deployment at remote sites with minimal local support. Processed data is provided for public viewing and download in real-time on our web site "http://hsrl.ssec.wisc.edu". Air pollution applications of HSRL data will be illustrated with examples acquired during air quality field programs including; KORUS-AQ, DISCOVER-AQ, LAMOS and FRAPPE. Observations include 1) long range transport of dust, air pollution and smoke. 2) Fumigation episodes where elevated pollution is mixed down to the surface. 3) visibility restrictions by aerosols and 4) diurnal variations in atmospheric optical depth. While HSRL is powerful air quality research tool, its application in routine measurement networks is hindered by the high cost of current systems. Recent technical advances promise a next generation HSRL using telcom components to greatly reduce system cost. This paper will present data generated by a prototype low cost system constructed at NCAR. In addition to lower cost, operation at a non-visible near 780 nm infrared wavelength removes all FAA restrictions on the operation.

  17. Quench propagation in High Temperature Superconducting materials integrated in high current leads

    CERN Document Server

    Milani, D

    2001-01-01

    High temperature superconductors (HTS) have been integrated in the high current leads for the Large Hadron Collider (LHC), under construction at CERN, in order to reduce the heat leak into the liquid helium bath due to the joule effect. The use of the HTS technology in the lower part of the current leads allowed to significantly reduce the heat charge on the cryogenic system. Hybrid current leads have been designed to fulfill the LHC requirements with respect to thermal load; several tests have been performed to study the lead behavior especially during a quench transient. Quench experiments have been performed at CERN on 13 kA prototypes to determine the adequate design and protection. In all the tests it is possible to know the temperature profile of the HTS only with the help of quench simulations that model the thermo-hydraulic processes during quench. The development of a theoretical model for the simulation allows reducing the number of test to perform and to scale the experimental result to other curre...

  18. Cryopreservation in fish: current status and pathways to quality assurance and quality control in repository development.

    Science.gov (United States)

    Torres, Leticia; Hu, E; Tiersch, Terrence R

    2016-01-07

    Cryopreservation in aquatic species in general has been constrained to research activities for more than 60 years. Although the need for application and commercialisation pathways has become clear, the lack of comprehensive quality assurance and quality control programs has impeded the progress of the field, delaying the establishment of germplasm repositories and commercial-scale applications. In this review we focus on the opportunities for standardisation in the practices involved in the four main stages of the cryopreservation process: (1) source, housing and conditioning of fish; (2) sample collection and preparation; (3) freezing and cryogenic storage of samples; and (4) egg collection and use of thawed sperm samples. In addition, we introduce some key factors that would assist the transition to commercial-scale, high-throughput application.

  19. Adoption and impact of high quality bambara flour (HQBF ...

    African Journals Online (AJOL)

    Adoption and impact of high quality bambara flour (HQBF) technology in the ... consumer acceptability/quality of products, credit, availability of raw materials, and ... as a result of 12.5 per cent increase in demand for bambara-based products.

  20. Development of a high-quality cut-off wall using electrophoresis

    International Nuclear Information System (INIS)

    Kawachi, T.; Murahashi, H.

    1991-01-01

    Techniques to build a high-quality cut-off wall have been developed for storage facilities of low-level radioactive waste (LLW) as an emergency measures to prevent leakages. The cut-off wall is highly impermeable, nucleid-adsorptive and have long-term durability. Electrophoresis is used to form impermeable membrane of bentonite as main features of the cut-off wall. First of all, laboratory tests have been conducted to study ways of building barriers on site and to collect data on the barriers properties. Afterwards, on-site construction tests of a high-quality cut-off wall have been carried out. In this paper, we describe the process and results on the studies of the high-quality cut-off wall using electrophoresis

  1. Radiation quality and radiation risks - some current problems

    International Nuclear Information System (INIS)

    Kellerer, A.M.; Hahn, K.

    1989-01-01

    The newly evaluated cancer mortality data of the atomic bomb survivors suggest substantially enhanced risk estimates, and the various factors that are involved in the change are considered. The enhanced risk estimates have already led to added restrictions in the dose limits for radiation workers, and there may be a further tightening of regulations in the future. The impending revision of the quality factors in radiation protection may, therefore, lead to practical difficulties, and a careful consideration of the various aspects involved in a revision is required. A liaison group of ICRU and ICRP has proposed a reformulation of the quality factor that is related not to the LET, but to the microdosimetric variably y. The relation leads to increased quality factors for neutrons, but also to a quality factor for γ rays of only 0.5. Alternatives are presented that relate the quality factor to LET and that retain γ- rays as the reference radiation. One option corresponds to different quality factors for γ rays and X-rays, the other option sets the quality factor for photons approximately equal to unity, irrespective of energy. (author)

  2. Timing of high-quality child care and cognitive, language, and preacademic development.

    Science.gov (United States)

    Li, Weilin; Farkas, George; Duncan, Greg J; Burchinal, Margaret R; Vandell, Deborah Lowe

    2013-08-01

    The effects of high- versus low-quality child care during 2 developmental periods (infant-toddlerhood and preschool) were examined using data from the National Institute of Child Health and Human Development Study of Early Child Care. Propensity score matching was used to account for differences in families who used different combinations of child care quality during the 2 developmental periods. Findings indicated that cognitive, language, and preacademic skills prior to school entry were highest among children who experienced high-quality care in both the infant-toddler and preschool periods, somewhat lower among children who experienced high-quality child care during only 1 of these periods, and lowest among children who experienced low-quality care during both periods. Irrespective of the care received during infancy-toddlerhood, high-quality preschool care was related to better language and preacademic outcomes at the end of the preschool period; high-quality infant-toddler care, irrespective of preschool care, was related to better memory skills at the end of the preschool period. (PsycINFO Database Record (c) 2013 APA, all rights reserved).

  3. High current superconductors for DEMO

    Energy Technology Data Exchange (ETDEWEB)

    Bruzzone, Pierluigi, E-mail: pierluigi.bruzzone@psi.ch [Ecole Polytechnique Fédérale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas (CRPP), Association Euratom – Confédération Suisse, CH-5232 Villigen PSI (Switzerland); Sedlak, Kamil; Stepanov, Boris [Ecole Polytechnique Fédérale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas (CRPP), Association Euratom – Confédération Suisse, CH-5232 Villigen PSI (Switzerland)

    2013-10-15

    Highlights: ► Definition of requirement for TF coil based on the input of system code. ► A TF coil and conductor design for the European DEMO project. ► Use of React and Wind method opposite to Wind and React with related advantages. ► Hybridization of winding pack, Nb/Nb{sub 3}Sn, by graded layer winding. -- Abstract: In the assumption that DEMO will be an inductively driven tokamak, the number of load cycles will be in the range of several hundred thousands. The requirements for a new generation of Nb{sub 3}Sn based high current conductors for DEMO are drafted starting from the output of system code PROCESS. The key objectives include the stability of the DC performance over the lifetime of the machine and the effective use of the Nb{sub 3}Sn strand properties, for cost and reliability reasons. A preliminary layout of the winding pack and conductors for the toroidal field magnets is presented. To suppress the mechanism of reversible and irreversible degradation, i.e. to preserve in the cabled conductor the high critical current density of the strand, the thermal strain must be insignificant and no space for micro-bending under transverse load must be left in the strand bundle. The “react-and-wind” method is preferred here, with a graded, layer wound magnet, containing both Nb{sub 3}Sn and NbTi layers. The implications of the conductor choice on the coil design and technology are highlighted. A roadmap is sketched for the development of a full size prototype conductor sample and demonstration of the key technologies.

  4. Development of pulsed high current drivers for fast Z-pinch

    International Nuclear Information System (INIS)

    Sun Fengju; Qiu Aici; Zeng Zhengzhong; Zeng Jiangtao; Kuai Bin; Yang Hailiang

    2006-01-01

    It is required that the peak current of high power pulsed drive for fast Z-pinch reaches 60 MA to realize inertial confine fusion (ICF) and high yield (HY). With the conventional technological methods similar to the Z or Saturn apparatus, increasing driver current further is impractical and difficult according to the cost, structure complexity and reliability of the driver, so it is necessary to develop novel fast pulsed high current driver. The present art-of-state and trends of fast Z-pinch driver are summarized, and the typical conceptual designs and technological methods on ICF/HY PRS (plasma radiation source) and destroying-level super X-ray simulators in USA and Russia are outlined, such as HCEI's UGXX1 driver and new Saturn driver based on fast linear transformer driver (FLTD) and novel driver based on fast Marx generator (FMG) with current of 15 MA. The crucial technological problems and requirements to investigate in the future are presented. (authors)

  5. Health-Related Quality of Life in Children with High-Functioning Autism

    Science.gov (United States)

    Potvin, Marie-Christine; Snider, Laurie; Prelock, Patricia A.; Wood-Dauphinee, Sharon; Kehayia, Eva

    2015-01-01

    The health-related quality of life of school-aged children with high-functioning autism is poorly understood. The objectives of this study were to compare the health-related quality of life of children with high-functioning autism to that of typically developing peers and to compare child-self and parent-proxy reports of health-related quality of…

  6. High quality digital holographic reconstruction on analog film

    Science.gov (United States)

    Nelsen, B.; Hartmann, P.

    2017-05-01

    High quality real-time digital holographic reconstruction, i.e. at 30 Hz frame rates, has been at the forefront of research and has been hailed as the holy grail of display systems. While these efforts have produced a fascinating array of computer algorithms and technology, many applications of reconstructing high quality digital holograms do not require such high frame rates. In fact, applications such as 3D holographic lithography even require a stationary mask. Typical devices used for digital hologram reconstruction are based on spatial-light-modulator technology and this technology is great for reconstructing arbitrary holograms on the fly; however, it lacks the high spatial resolution achievable by its analog counterpart, holographic film. Analog holographic film is therefore the method of choice for reconstructing highquality static holograms. The challenge lies in taking a static, high-quality digitally calculated hologram and effectively writing it to holographic film. We have developed a theoretical system based on a tunable phase plate, an intensity adjustable high-coherence laser and a slip-stick based piezo rotation stage to effectively produce a digitally calculated hologram on analog film. The configuration reproduces the individual components, both the amplitude and phase, of the hologram in the Fourier domain. These Fourier components are then individually written on the holographic film after interfering with a reference beam. The system is analogous to writing angularly multiplexed plane waves with individual component phase control.

  7. High performance current generator with one-picoampere resolution

    International Nuclear Information System (INIS)

    Grillo, L.; Manfredi, P.F.; Marchesini, R.

    1975-01-01

    A high-performance current generator for the picoampere region is presented. Although it was primarily developed as a part of an automatic test system to calibrate charge integrators for accelerating machines. It can suit a wide range of applications. It consists basically of a positive feedback loop of controlled gain which includes a varactor bridge operational amplifier. The essential features of the instrument are a 1 pA resolution and a 10 15 Ω output impedance. The output is guarded and floating between - 120 V and + 120 V, and the voltage across the external loads is measured without affecting the delivered current by a digital panel meter on the front panel. The unit can therefore operate as a high-accuracy dc impedance meter. (Auth.)

  8. Testing and evaluation of high temperature superconductor current leads

    International Nuclear Information System (INIS)

    Yadav, Anand; Puntambekar, Avinash; Manekar, M.A.

    2009-01-01

    National Institute for Inter-disciplinary Science and Technology (NIIST), Council of Scientific and Industrial Research, Trivandrum (formerly Regional Research Laboratory) has accomplished a DAE-BRNS project with Raja Ramanna Centre for Advanced Technology (RRCAT) as principal collaborator for the development of high temperature superconductor (HTS) current leads. These HTS current leads have self-field critical currents (Ic) ranging from 50 A to 1000 A at liquid nitrogen (LN 2 ) temperature. These HTS are made out of silver sheathed Bismuth Strontium Calcium Copper Oxide (BSCCO-2223), for direct application in superconducting (SC) systems involving transportation of high electric currents from power sources at room temperature to superconducting devices at cryogenic temperatures. RRCAT has participated in this project by testing and evaluation of these HTS current leads and carried out actual load trials. In this paper, we will describe the HTS testing setup, tests performed with their testing procedure and the test results. The testing of these HTS has been done with joint effort of Materials Advanced Accelerator Science and Cryogenics Div. and Superconducting Technology Lab (SCT Lab), Advanced Accelerator Module Development Div., using the test facility available at the SCT Lab. (author)

  9. Broad-beam, high current, metal ion implantation facility

    International Nuclear Information System (INIS)

    Brown, I.G.; Dickinson, M.R.; Galvin, J.E.; Godechot, X.; MacGill, R.A.

    1990-07-01

    We have developed a high current metal ion implantation facility with which high current beams of virtually all the solid metals of the Periodic Table can be produced. The facility makes use of a metal vapor vacuum arc ion source which is operated in a pulsed mode, with pulse width 0.25 ms and repetition rate up to 100 pps. Beam extraction voltage is up to 100 kV, corresponding to an ion energy of up to several hundred keV because of the ion charge state multiplicity; beam current is up to several Amperes peak and around 10 mA time averaged delivered onto target. Implantation is done in a broad-beam mode, with a direct line-of-sight from ion source to target. Here we describe the facility and some of the implants that have been carried out using it, including the 'seeding' of silicon wafers prior to CVD with titanium, palladium or tungsten, the formation of buried iridium silicide layers, and actinide (uranium and thorium) doping of III-V compounds. 16 refs., 6 figs

  10. Processing and critical currents of high-Tc superconductor wires

    International Nuclear Information System (INIS)

    Krauth, H.; Heine, K.; Tenbrink, J.

    1991-01-01

    High-Tc superconductors are expected to have a major impact on magnet and energy technology. For technical applications they have to fulfill the requirement of carrying sufficient current at a critical current density of the order of 10 5 A/cm 2 at operating temperature and magnetic field. At 77 K these values have not been achieved yet in bulk material or wires due to weak link problems and flux creep effects. Progress made so far and remaining problems will be discussed in detail concentrating on problems concerning development of technical wires. In Bi-based materials technically interesting critical current densities could be achieved at 4.2 K in fields above 20 T (1,2), rendering possible the use of such material for very high field application. (orig.)

  11. High quality TmIG films with perpendicular magnetic anisotropy grown by sputtering

    Science.gov (United States)

    Wu, C. N.; Tseng, C. C.; Yeh, S. L.; Lin, K. Y.; Cheng, C. K.; Fanchiang, Y. T.; Hong, M.; Kwo, J.

    Ferrimagnetic thulium iron garnet (TmIG) films grown on gadolinium gallium garnet substrates recently showed stress-induced perpendicular magnetic anisotropy (PMA), attractive for realization of quantum anomalous Hall effect (QAHE) of topological insulator (TI) films via the proximity effect. Moreover, current induced magnetization switching of Pt/TmIG has been demonstrated for the development of room temperature (RT) spintronic devices. In this work, high quality TmIG films (about 25nm) were grown by sputtering at RT followed by post-annealing. We showed that the film composition is tunable by varying the growth parameters. The XRD results showed excellent crystallinity of stoichiometric TmIG films with an out-of-plane lattice constant of 1.2322nm, a narrow film rocking curve of 0.017 degree, and a film roughness of 0.2 nm. The stoichiometric films exhibited PMA and the saturation magnetization at RT was 109 emu/cm3 (RT bulk value 110 emu/cm3) with a coercive field of 2.7 Oe. In contrast, TmIG films of Fe deficiency showed in-plane magnetic anisotropy. The high quality sputtered TmIG films will be applied to heterostructures with TIs or metals with strong spin-orbit coupling for novel spintronics.

  12. Quench protection and design of large high-current-density superconducting magnets

    International Nuclear Information System (INIS)

    Green, M.A.

    1981-03-01

    Although most large superconducting magnets have been designed using the concept of cryostability, there is increased need for large magnets which operate at current densities above the cryostable limit (greater than 10 8 Am -2 ). Large high current density superconducting magnets are chosen for the following reasons: reduced mass, reduced coil thickness or size, and reduced cost. The design of large high current density, adiabatically stable, superconducting magnets requires a very different set of design rules than either large cryostable superconducting magnets or small self-protected high current density magnets. The problems associated with large high current density superconducting magnets fall into three categories; (a) quench protection, (b) stress and training, and (c) cryogenic design. The three categories must be considered simultaneously. The paper discusses quench protection and its implication for magnets of large stored energies (this includes strings of smaller magnets). Training and its relationship to quench protection and magnetic strain are discussed. Examples of magnets, built at the Lawrence Berkeley Laboratory and elsewhere using the design guidelines given in this report, are presented

  13. High-energy tritium beams as current drivers in tokamak reactors

    International Nuclear Information System (INIS)

    Mikkelsen, D.R.; Grisham, L.R.

    1983-04-01

    The effect on neutral-beam design and reactor performance of using high-energy (approx. 3-10 MeV) tritium neutral beams to drive steady-state tokamak reactors is considered. The lower current of such beams leads to several advantages over lower-energy neutral beams. The major disadvantage is the reduction of the reactor output caused by the lower current-drive efficiency of the high-energy beams

  14. Fabrication and characterization of high quality n-ZnO/p-GaN heterojunction light emission diodes

    International Nuclear Information System (INIS)

    Zheng Hao; Mei, Z.X.; Zeng, Z.Q.; Liu, Y.Z.; Guo, L.W.; Jia, J.F.; Xue, Q.K.; Zhang, Z.; Du, X.L.

    2011-01-01

    High quality single crystalline n-type ZnO film was grown on p-type GaN substrate using molecular beam epitaxy. Transmission electron microscopy reveals a sharp ZnO/GaN interface. Light-emitting diode was fabricated from this heterostructure, and a turn-on voltage of ∼ 3.4 V was demonstrated. We found that the emission peak shifts from violet (430 nm) to near-ultraviolet (375 nm) when the driving current increases from 0.38 mA to 3.08 mA. This intriguing phenomenon can be understood by charged carrier's radical recombination occurring at both sides of the device, and the current enhancement of ZnO emission efficiency.

  15. Liposomal Drug Product Development and Quality: Current US Experience and Perspective.

    Science.gov (United States)

    Kapoor, Mamta; Lee, Sau L; Tyner, Katherine M

    2017-05-01

    Research in the area of liposomes has grown substantially in the past few decades. Liposomes are lipid bilayer structures that can incorporate drug substances to modify the drug's pharmacokinetic profile thereby improving drug delivery. The agency has received over 400 liposomal drug product submissions (excluding combination therapies), and there are currently eight approved liposomal drug products on the US market. In order to identify the pain points in development and manufacturing of liposomal drug products, a retrospective analysis was performed from a quality perspective on submissions for new and generic liposomal drug products. General analysis on liposomal drug product submissions was also performed. Results indicated that 96% of the submissions were Investigational New Drug (IND) applications, 3% were New Drug Applications (NDAs), and the remaining 1% was Abbreviated New Drug Applications (ANDAs). Doxorubicin hydrochloride was the most commonly used drug substance incorporated into the liposomes (31%). The majority of the liposomal products were administered via intravenous route (84%) with cancer (various types) being the most common indication (63%). From a quality perspective, major challenges during the development of liposomal drug products included identification and (appropriate) characterization of critical quality attributes of liposomal drug products and suitable control strategies during product development. By focusing on these areas, a faster and more efficient development of liposomal drug products may be achieved. Additionally, in this way, the drug review process for such products can be streamlined.

  16. Enhanced performance on high current discharges in JET produced by ICRF heating during the current rise

    International Nuclear Information System (INIS)

    Bures, M.; Bhatnagar, V.; Cotrell, G.; Corti, S.; Christiansen, J.P.; Hellsten, T.; Jacquinot, J.; Lallia, P.; Lomas, P.; O'Rourke, J.; Taroni, A.; Tibone, F.; Start, D.F.H.

    1989-01-01

    The performance of high current discharges can be increased by applying central ICRF heating before or shortly after the onset of sawtooth activity in the plasma current rise phase. Sawtooth-free periods have been obtained resulting in the enhanced discharge performance. High T e (0) 9 - 10.5 keV with peaked profiles T e (0)/ e > = 3 - 4 were obtained giving values of n e (0)T e (0) up to 6x10 20 (keV m -3 ). Improvements in T i (0) and neutron production are observed. A 60 % enhancement in D-D reaction rate from 2nd harmonic deuterium (2ω CD ) heating appears to be present. In all current rise (CR) discharges radiation amounts to 25-50 % of total power. (author) 4 refs., 6 figs

  17. A review of high beam current RFQ accelerators and funnels

    International Nuclear Information System (INIS)

    Schneider, J.D.

    1998-01-01

    The authors review the design features of several high-current (> 20-mA) and high-power (> 1-mA average) proton or H - injectors, RFQs, and funnels. They include a summary of observed performance and will mention a sampling of new designs, including the proposed incorporation of beam choppers. Different programs and organizations have chosen to build the RFQ in diverse configurations. Although the majority of RFQs are either low-current or very low duty-factor, several versions have included high-current and/or high-power designs for either protons or H - ions. The challenges of cooling, handling high space-charge forces, and coupling with injectors and subsequent accelerators are significant. In all instances, beam tests were a valuable learning experience, because not always did these as-built structures perform exactly as predicted by the earlier design codes. They summarize the key operational parameters, indicate what was achieved, and highlight what was learned in these tests. Based on this generally good performance and high promise, even more challenging designs are being considered for new applications that include even higher powers, beam funnels and choppers

  18. High-transport current density up to 30 T in bulk YBa2Cu3O7 and the critical angle effect

    International Nuclear Information System (INIS)

    Ekin, J.W.; Salama, K.; Selvamanickam, V.

    1991-01-01

    Measurements of the dc transport critical current of oriented-grained YBa 2 Cu 3 O 7 have been made using high quality Ag contacts and a high-current sample mount. The critical- current density J c at 77 K for mutually perpendicular current and magnetic field B in the a,b plane is 8 kA/cm 2 at 8 T, decreasing gradually to 3.7 kA/cm 2 at 20 T, and remaining over 1 kA/cm 2 out to 30 T. High magnetic field measurements of J c as a function of the angle θ of B with respect to the c axis are also reported. In contrast to earlier results at lower fields ( c vs θ curve with a head-and-shoulders shape, consisting of a sharp peak (''head'') 2 planes, and a wide (30 degree at 9 T, for example) shoulder region on either side of B perpendicular c, where the transport J c remains high and constant. Beyond the shoulder region, however, the transport J c decreases sharply, giving rise to the concept of a critical field angle for application design, defined by the minima in d 2 J c /dθ 2 at the edge of the shoulders

  19. Compilation of current high-energy-physics experiments

    International Nuclear Information System (INIS)

    Wohl, C.G.; Kelly, R.L.; Armstrong, F.E.

    1980-04-01

    This is the third edition of a compilation of current high energy physics experiments. It is a collaborative effort of the Berkeley Particle Data Group, the SLAC library, and ten participating laboratories: Argonne (ANL), Brookhaven (BNL), CERN, DESY, Fermilab (FNAL), the Institute for Nuclear Study, Tokyo (INS), KEK, Rutherford (RHEL), Serpukhov (SERP), and SLAC. The compilation includes summaries of all high energy physics experiments at the above laboratories that (1) were approved (and not subsequently withdrawn) before about January 1980, and (2) had not completed taking of data by 1 January 1976

  20. Application of radiofrequency superconductivity to accelerators for high-current ion beams

    International Nuclear Information System (INIS)

    Delayen, J.R.; Bohn, C.L.; Kennedy, W.L.; Roche, C.T.; Sagalovsky, L.

    1992-01-01

    A development program is underway to apply rf superconductivity to the design of continuous-wave (cw) linear accelerators for high-current, high-brightness ion beam. During the last few years, considerable progress has been made both experimentally and theoretically toward this application. Recent tests of niobium resonators for ion acceleration have yielded average accelerating gradients as high as 18 MV/m. In an experiment with a radio-frequency quadrupole geometry, niobium was found to sustain cw peak surface electric fields as high as 128 MV/m over large (10 cm) surface areas. Theoretical studies of beam halo, cumulative beam breakup and alternating-phase focusing have also yielded important results. This paper su-summarizes the recent progress and identifies current and future work in the areas of superconducting accelerator technology for high-current ion beams

  1. MHD Modeling of Conductors at Ultra-High Current Density

    International Nuclear Information System (INIS)

    ROSENTHAL, STEPHEN E.; DESJARLAIS, MICHAEL P.; SPIELMAN, RICK B.; STYGAR, WILLIAM A.; ASAY, JAMES R.; DOUGLAS, M.R.; HALL, C.A.; FRESE, M.H.; MORSE, R.L.; REISMAN, D.B.

    2000-01-01

    In conjunction with ongoing high-current experiments on Sandia National Laboratories' Z accelerator, the authors have revisited a problem first described in detail by Heinz Knoepfel. Unlike the 1-Tesla MITLs of pulsed power accelerators used to produce intense particle beams, Z's disc transmission line (downstream of the current addition) is in a 100--1,200 Tesla regime, so its conductors cannot be modeled simply as static infinite conductivity boundaries. Using the MHD code MACH2 they have been investigating the conductor hydrodynamics, characterizing the joule heating, magnetic field diffusion, and material deformation, pressure, and velocity over a range of current densities, current rise-times, and conductor materials. Three purposes of this work are (1) to quantify power flow losses owing to ultra-high magnetic fields, (2) to model the response of VISAR diagnostic samples in various configurations on Z, and (3) to incorporate the most appropriate equation of state and conductivity models into the MHD computations. Certain features are strongly dependent on the details of the conductivity model

  2. MHD Modeling of Conductors at Ultra-High Current Density

    International Nuclear Information System (INIS)

    Rosenthal, S.E.; Asay, J.R.; Desjarlais, M.P.; Douglas, M.R.; Frese, M.H.; Hall, C.A.; Morse, R.L.; Reisman, D.; Spielman, R.B.; Stygar, W.A.

    1999-01-01

    In conjunction with ongoing high-current experiments on Sandia National Laboratories' Z accelerator we have revisited a problem first described in detail by Heinz Knoepfel. MITLs of previous pulsed power accelerators have been in the 1-Tesla regime. Z's disc transmission line (downstream of the current addition) is in a 100-1200 Tesla regime, so its conductors cannot be modeled simply as static infinite conductivity boundaries. Using the MHD code MACH2 we have been investigating conductor hydrodynamics, characterizing the joule heating, magnetic field diffusion, and material deformation, pressure, and velocity over a range of current densities, current rise-times, and conductor materials. Three purposes of this work are ( 1) to quantify power flow losses owing to ultra-high magnetic fields, (2) to model the response of VISAR diagnostic samples in various configurations on Z, and (3) to incorporate the most appropriate equation of state and conductivity models into our MHD computations. Certain features are strongly dependent on the details of the conductivity model. Comparison with measurements on Z will be discussed

  3. Prediction of bread-making quality using size exclusion high ...

    African Journals Online (AJOL)

    Variation in the distribution of protein molecular weight in wheat (Triticum aestivum), influences breadmaking quality of wheat cultivars, resulting in either poor or good bread. The objective of this study was to predict breadmaking quality of wheat cultivars using size exclusion high performance liquid chromatography.

  4. Exome sequencing generates high quality data in non-target regions

    Directory of Open Access Journals (Sweden)

    Guo Yan

    2012-05-01

    Full Text Available Abstract Background Exome sequencing using next-generation sequencing technologies is a cost efficient approach to selectively sequencing coding regions of human genome for detection of disease variants. A significant amount of DNA fragments from the capture process fall outside target regions, and sequence data for positions outside target regions have been mostly ignored after alignment. Result We performed whole exome sequencing on 22 subjects using Agilent SureSelect capture reagent and 6 subjects using Illumina TrueSeq capture reagent. We also downloaded sequencing data for 6 subjects from the 1000 Genomes Project Pilot 3 study. Using these data, we examined the quality of SNPs detected outside target regions by computing consistency rate with genotypes obtained from SNP chips or the Hapmap database, transition-transversion (Ti/Tv ratio, and percentage of SNPs inside dbSNP. For all three platforms, we obtained high-quality SNPs outside target regions, and some far from target regions. In our Agilent SureSelect data, we obtained 84,049 high-quality SNPs outside target regions compared to 65,231 SNPs inside target regions (a 129% increase. For our Illumina TrueSeq data, we obtained 222,171 high-quality SNPs outside target regions compared to 95,818 SNPs inside target regions (a 232% increase. For the data from the 1000 Genomes Project, we obtained 7,139 high-quality SNPs outside target regions compared to 1,548 SNPs inside target regions (a 461% increase. Conclusions These results demonstrate that a significant amount of high quality genotypes outside target regions can be obtained from exome sequencing data. These data should not be ignored in genetic epidemiology studies.

  5. Test quality

    International Nuclear Information System (INIS)

    Hartley, R.S.; Keller, A.E.

    1992-01-01

    Inservice testing of safety-related components at nuclear power plants is performed under the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (the Code). Subsections IWP and IWV of Section 11 of the Code state test method and frequency requirements for pumps and valves, respectively. Tests vary greatly in quality and frequency. This paper explores the concept of test quality and its relationship with operational readiness and preventive maintenance. This paper also considers the frequencies of component testing. Test quality is related to a test's ability to detect degradation that can cause component failure. The quality of the test depends on several factors, including specific parameters measured, system or component conditions, and instrument accuracy. The quality of some currently required tests for check valves, motor-operated valves, and pumps is also discussed. Suggestions are made to improve test quality by measuring different parameters, testing valves under load, and testing positive displacement pumps at high pressure and centrifugal pumps at high flow rate conditions. These suggestions can help to improve the level of assurance of component operational readiness gained from testing

  6. Online diagnoses of high current-density beams

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.

    1994-01-01

    Los Alamos National Laboratory has proposed several CW-proton-beam facilities for production of tritium or transmutation of nuclear waste with beam-current densities greater than 5 mA/mm 2 . The primary beam-diagnostics-instrumentation requirement for these facilities is provision of sufficient beam information to understand and minimize beam-loss. To accomplish this task, the beam-diagnostics instrumentation must measure beam parameters such as the centroids and profiles, total integrated current, and particle loss. Noninterceptive techniques must be used for diagnosis of high-intensity CW beam at low energies due to the large quantity of power deposited in an interceptive diagnostic device by the beam. Transverse and longitudinal centroid measurements have been developed for bunched beams by measuring and processing image currents on the accelerator walls. Transverse beam-profile measurement-techniques have also been developed using the interaction of the particle beam with the background gases near the beam region. This paper will discuss these noninterceptive diagnostic Techniques

  7. Realisation and instrumentation of high current power station for superconducting cables testing

    International Nuclear Information System (INIS)

    Regnaud, S.

    2000-05-01

    This report deals with the designing of a high current station able to test electric properties of superconductors. This test station will be used for testing the superconducting wires of large hadron collider detectors in CERN. The high current test station will have to generate high intensity continuous current in a magnetic field of 0 to 5 tesla and in temperature conditions of 4.2 K. The length of wire samples submitted to the uniform magnetic field is 300 mm and the installation is fitted with equipment able to measure the magnetic field perpendicular to either faces of the wire. The peculiarity of this station is to use a superconducting transformer in order to generate the high current. The first part of this work recalls important notions concerning superconductivity. The second part presents the high current station by describing the superconducting transformer and the sample-holder. We have studied the designing of a transformer able to yield a secondary current whose intensity reaches 100 kA, such intensity generates powerful electromagnetic forces (566 kN/m) in case of defect, so the sample-holder has to be carefully design to bear them. The third part presents the cryogenic component of the station, the instrumentation of the sample-holder and the method used to measure secondary currents. In the last part we present the performance of a prototype transformer, this prototype is able to deliver a 22 kA secondary current for a 160 A primary current, the uncertainty on the measured value of the secondary current is about 3%

  8. Limiting stable states of high-Tc superconductors in the alternating current modes

    International Nuclear Information System (INIS)

    Romanovskii, V.R.; Watanabe, K.; Awaji, S.

    2014-01-01

    The limiting current-carrying capacity of high-T c superconductor and superconducting tape has been studied in the alternating current states. The features that are responsible for their stable formation have been investigated under the conduction-cooled conditions when the operating peak values of the electric field and the current may essentially exceed the corresponding critical values of superconductor. Besides, it has been proved that these peak values are higher than the values of the electric field and the current, which lead to the thermal runaway phenomenon when the current instability onset occurs in the operating modes with direct current. As a result, the stable extremely high heat generation exists in these operating states, which can be called as overloaded states. The limiting stable peak values of charged currents and stability conditions have been determined taking into account the flux creep states of superconductors. The analysis performed has revealed that there exist characteristic times defining the corresponding time windows in the stable development of overloaded states of the alternating current. In order to explain their existence, the basic thermo-electrodynamics mechanisms have been formulated, which have allowed to explain the high stable values of the temperature and the induced electric field before the onset of alternating current instability. In general, it has been shown that the high-T c superconductors may stably operate in the overloaded alternating current states even under the not intensive cooling conditions at a very high level of heat generation, which is not considered in the existing theory of losses. (authors)

  9. Oscillographic Chronopotentiometry with High and Low Frequency Current

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A novel electroanalytical method, oscillographic chronopotentiometry with high and low frequency current, is presented in this paper. With this method, the sensitivity of almost all kinds of oscillographic chronopotentiometry can be enhanced about one order.

  10. Investigation of iron current measurement to detect combustion quality; Ion denryu ni yoru nensho jotai kenshutsu no kento

    Energy Technology Data Exchange (ETDEWEB)

    Nakata, K; Mogi, K [Toyota Motor Corp., Aichi (Japan)

    1997-10-01

    The possibility and problems were investigated in detecting the combustion quality by means of ion current measured at the spark plug. The ion current has two peaks during one combustion stroke; first peak is generated by flame around the spark plug just after ignition and second one appears with the rise in temperature of burned gases. As the result of investigations, it was confirmed that the first ion peak might be useful to forecast the combustion quality, but it would be hard to practice owing to the spark duration. And the second peak offered the information of combustion chamber pressure. 4 refs., 12 figs., 1 tab.

  11. Linking Quality Assurance to Performance Improvement to Produce a High Reliability Organization

    International Nuclear Information System (INIS)

    Silvey, Andrea B.; Warrick, Louise H.

    2008-01-01

    Three basic change management models are currently used in healthcare to produce and sustain quality improvement. We have presented the context to determine where any particular organization stands within these paradigms. We also have introduced a change-management tool used to assess, plan, and monitor leadership effort and commitment to quality improvement and culture change activities, tracked as 'momentum for change.' This 'momentum' is measured at eight discrete levels, from recognizing a performance gap to officially implementing changes intended to improve quality

  12. Key factors for a high-quality VR experience

    Science.gov (United States)

    Champel, Mary-Luc; Doré, Renaud; Mollet, Nicolas

    2017-09-01

    For many years, Virtual Reality has been presented as a promising technology that could deliver a truly new experience to users. The media and entertainment industry is now investigating the possibility to offer a video-based VR 360 experience. Nevertheless, there is a substantial risk that VR 360 could have the same fate as 3DTV if it cannot offer more than just being the next fad. The present paper aims at presenting the various quality factors required for a high-quality VR experience. More specifically, this paper will focus on the main three VR quality pillars: visual, audio and immersion.

  13. Resistive current limiter with high-temperature superconductors. Final report

    International Nuclear Information System (INIS)

    Schubert, M.

    1995-12-01

    Fundamental results of the possibility of using high temperature superconductors (HTSC) in resistive fault current limiters are discussed. Measurement of the homogeneity of BSCCO-powder-in-tube materials were made. In addition, investigations of the transition from superconducting to normalconducting state under AC-current conditions were carried out. Based on these results, simulations of HTSC-materials on ceramic substrate were made and recent results are presented. Important results of the investigations are: 1. Current-limiting without external trigger only possible when the critical current density of HTSC exceeds 10 4 A/cm 2 . 2. Inhomogeneities sometimes cause problems with local destruction. This can be solved by parallel-elements or external trigger. 3. Fast current-limiting causes overvoltages which can be reduced by using parallel-elements. (orig.) [de

  14. Water Recycling via Aquifers for Sustainable Urban Water Quality Management: Current Status, Challenges and Opportunities

    Directory of Open Access Journals (Sweden)

    Elise Bekele

    2018-04-01

    Full Text Available Managed aquifer recharge (MAR is used worldwide in urban environments to replenish groundwater to provide a secure and sustainable supply of potable and non-potable water. It relies on natural treatment processes within aquifers (i.e., filtration, sorption, and degradation, and in some cases involves infiltration through the unsaturated zone to polish the given source water, e.g., treated wastewater, stormwater, or rainwater, to the desired quality prior to reuse. Whilst MAR in its early forms has occurred for millennia, large-scale schemes to replenish groundwater with advanced treated reclaimed water have come to the fore in cities such as Perth, Western Australia, Monterey, California, and Changwon, South Korea, as water managers consider provision for projected population growth in a drying climate. An additional bonus for implementing MAR in coastal aquifers is assisting in the prevention of seawater intrusion. This review begins with the rationale for large-scale MAR schemes in an Australian urban context, reflecting on the current status; describes the unique benefits of several common MAR types; and provides examples from around the world. It then explores several scientific challenges, ranging from quantifying aquifer removal for various groundwater contaminants to assessing risks to human health and the environment, and avoiding adverse outcomes from biogeochemical changes induced by aquifer storage. Scientific developments in the areas of water quality assessments, which include molecular detection methods for microbial pathogens and high resolution analytical chemistry methods for detecting trace chemicals, give unprecedented insight into the “polishing” offered by natural treatment. This provides opportunities for setting of compliance targets for mitigating risks to human health and maintaining high performance MAR schemes.

  15. High-frequency, three-phase current controller implementation in an FPGA

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, M.; Round, S. D.; Kolar, J. W.

    2008-07-01

    Three phase rectifiers with switching frequencies of 500 kHz or more require high speed current controllers. At such high switching frequencies analog controllers as well as high speed digital signal processing (DSP) systems have limited performance. In this paper, two high speed current controller implementations using two different field-programmable gate arrays (FPGA) - one for switching frequencies up to 1 MHz and one for switching frequencies beyond 1 MHz - are presented to overcome this performance limitation. Starting with the digital system design all the blocks of the signal chain, containing analog-to-digital (A/D) interface, digital controller implementation using HW-multipliers and implementation of a novel high speed, high resolution pulse width modulation (PWM) are discussed and compared. Final measurements verify the performance of the controllers. (author)

  16. High current density aluminum stabilized conductor concepts for space applications

    International Nuclear Information System (INIS)

    Huang, X.; Eyssa, Y.M.; Hilal, M.A.

    1989-01-01

    Lightweight conductors are needed for space magnets to achieve values of E/M (energy stored per unit mass) comparable to the or higher than advanced batteries. High purity aluminum stabilized NbTi composite conductors cooled by 1.8 K helium can provide a winding current density up to 15 kA/cm/sup 2/ at fields up to 10 tesla. The conductors are edge cooled with enough surface area to provide recovery following a normalizing disturbance. The conductors are designed so that current diffusion time in the high purity aluminum is smaller than thermal diffusion time in helium. Conductor design, stability and current diffusion are considered in detail

  17. Method for controlling low-energy high current density electron beams

    International Nuclear Information System (INIS)

    Lee, J.N.; Oswald, R.B. Jr.

    1977-01-01

    A method and an apparatus for controlling the angle of incidence of low-energy, high current density electron beams are disclosed. The apparatus includes a current generating diode arrangement with a mesh anode for producing a drifting electron beam. An auxiliary grounded screen electrode is placed between the anode and a target for controlling the average angle of incidence of electrons in the drifting electron beam. According to the method of the present invention, movement of the auxiliary screen electrode relative to the target and the anode permits reliable and reproducible adjustment of the average angle of incidence of the electrons in low energy, high current density relativistic electron beams

  18. Prototype high current, high duty factor negative hydrogen ion source for LAMPF

    International Nuclear Information System (INIS)

    Lawrence, G.P.; Hayward, T.D.; Jackson, J.A.

    1975-01-01

    Present plans for the high current proton storage ring at LAMPF incorporate charge changing (stripping) injection of H - ions in all modes of operation. Achievable stored current levels in this device will be strongly dependent on the maximum H - beam intensity which can be accelerated by the linac, consistent with acceptable beam spill. This requirement has stimulated a program to develop an H - ion source capable of providing a suitably high peak current (up to 25 mA) at high duty factor (up to 12 percent), with a normalized x,x' or y,y' emittance acceptable to the accelerating system. There are presently two main approaches which could lead to H - ion sources providing this kind of performance. These are (a) the charge exchange method, in which an intense proton beam is fractionally converted to H - beam in a suitable charge adding medium, and (b) the direct extraction method, in which H - ions are obtained by a surface emission process associated with a gas discharge plasma. While both approaches may eventually find optimum application in different situations, it is not obvious, at present, which scheme will turn out to be the most satisfactory for LAMPF. A prototype charge exchange H - ion source has been constructed as a first step in the development program and is presently being evaluated. Work on surface emission direct extraction techniques is in the planning stages. (U.S.)

  19. Quality management in European screening laboratories in blood establishments: A view of current approaches and trends.

    Science.gov (United States)

    Pereira, Paulo; Westgard, James O; Encarnação, Pedro; Seghatchian, Jerard; de Sousa, Gracinda

    2015-04-01

    The screening laboratory has a critical role in the post-transfusion safety. The success of its targets and efficiency depends on the management system used. Even though the European Union directive 2002/98/EC requires a quality management system in blood establishments, its requirements for screening laboratories are generic. Complementary approaches are needed to implement a quality management system focused on screening laboratories. This article briefly discusses the current good manufacturing practices and good laboratory practices, as well as the trends in quality management system standards. ISO 9001 is widely accepted in some European Union blood establishments as the quality management standard, however this is not synonymous of its successful application. The ISO "risk-based thinking" is interrelated with the quality risk-management process of the EuBIS "Standards and criteria for the inspection of blood establishments". ISO 15189 should be the next step on the quality assurance of a screening laboratory, since it is focused on medical laboratory. To standardize the quality management systems in blood establishments' screening laboratories, new national and European claims focused on technical requirements following ISO 15189 is needed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Simultaneous PET/MR imaging in a human brain PET/MR system in 50 patients—Current state of image quality

    International Nuclear Information System (INIS)

    Schwenzer, N.F.; Stegger, L.; Bisdas, S.; Schraml, C.; Kolb, A.; Boss, A.; Müller, M.

    2012-01-01

    Objectives: The present work illustrates the current state of image quality and diagnostic accuracy in a new hybrid BrainPET/MR. Materials and methods: 50 patients with intracranial masses, head and upper neck tumors or neurodegenerative diseases were examined with a hybrid BrainPET/MR consisting of a conventional 3T MR system and an MR-compatible PET insert. Directly before PET/MR, all patients underwent a PET/CT examination with either [ 18 F]-FDG, [ 11 C]-methionine or [ 68 Ga]-DOTATOC. In addition to anatomical MR scans, functional sequences were performed including diffusion tensor imaging (DTI), arterial spin labeling (ASL) and proton-spectroscopy. Image quality score of MR imaging was evaluated using a 4-point-scale. PET data quality was assessed by evaluating FDG-uptake and tumor delineation with [ 11 C]-methionine and [ 68 Ga]-DOTATOC. FDG uptake quantification accuracy was evaluated by means of ROI analysis (right and left frontal and temporo-occipital lobes). The asymmetry indices and ratios between frontal and occipital ROIs were compared. Results: In 45/50 patients, PET/MR examination was successful. Visual analysis revealed a diagnostic image quality of anatomical MR imaging (mean quality score T2 FSE: 1.27 ± 0.54; FLAIR: 1.38 ± 0.61). ASL and proton-spectroscopy was possible in all cases. In DTI, dental artifacts lead to one non-diagnostic dataset (mean quality score DTI: 1.32 ± 0.69; ASL: 1.10 ± 0.31). PET datasets of PET/MR and PET/CT offered comparable tumor delineation with [ 11 C]-methionine; additional lesions were found in 2/8 [ 68 Ga]-DOTATOC-PET in the PET/MR. Mean asymmetry index revealed a high accordance between PET/MR and PET/CT (1.5 ± 2.2% vs. 0.9 ± 3.6%; mean ratio (frontal/parieto-occipital) 0.93 ± 0.08 vs. 0.96 ± 0.05), respectively. Conclusions: The hybrid BrainPET/MR allows for molecular, anatomical and functional imaging with uncompromised MR image quality and a high accordance of PET results between PET/MR and PET

  1. Simultaneous PET/MR imaging in a human brain PET/MR system in 50 patients-Current state of image quality

    Energy Technology Data Exchange (ETDEWEB)

    Schwenzer, N.F., E-mail: nina.schwenzer@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Stegger, L., E-mail: stegger@gmx.net [Department of Nuclear Medicine and European Institute for Molecular Imaging, University of Muenster, Muenster (Germany); Bisdas, S., E-mail: sbisdas@gmail.com [Department of Diagnostic and Interventional Neuroradiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Schraml, C., E-mail: christina.schraml@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Kolb, A., E-mail: armin.kolb@med.uni-tuebingen.de [Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation, Department of Preclinical Imaging and Radiopharmacy, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Boss, A., E-mail: Andreas.Boss@usz.ch [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Institute of Diagnostic and Interventional Radiology, University Hospital Zuerich, Zuerich (Switzerland); Mueller, M., E-mail: mark.mueller@med.uni-tuebingen.de [Department of Nuclear Medicine, Eberhard-Karls University Tuebingen, Tuebingen (Germany); and others

    2012-11-15

    Objectives: The present work illustrates the current state of image quality and diagnostic accuracy in a new hybrid BrainPET/MR. Materials and methods: 50 patients with intracranial masses, head and upper neck tumors or neurodegenerative diseases were examined with a hybrid BrainPET/MR consisting of a conventional 3T MR system and an MR-compatible PET insert. Directly before PET/MR, all patients underwent a PET/CT examination with either [{sup 18}F]-FDG, [{sup 11}C]-methionine or [{sup 68}Ga]-DOTATOC. In addition to anatomical MR scans, functional sequences were performed including diffusion tensor imaging (DTI), arterial spin labeling (ASL) and proton-spectroscopy. Image quality score of MR imaging was evaluated using a 4-point-scale. PET data quality was assessed by evaluating FDG-uptake and tumor delineation with [{sup 11}C]-methionine and [{sup 68}Ga]-DOTATOC. FDG uptake quantification accuracy was evaluated by means of ROI analysis (right and left frontal and temporo-occipital lobes). The asymmetry indices and ratios between frontal and occipital ROIs were compared. Results: In 45/50 patients, PET/MR examination was successful. Visual analysis revealed a diagnostic image quality of anatomical MR imaging (mean quality score T2 FSE: 1.27 {+-} 0.54; FLAIR: 1.38 {+-} 0.61). ASL and proton-spectroscopy was possible in all cases. In DTI, dental artifacts lead to one non-diagnostic dataset (mean quality score DTI: 1.32 {+-} 0.69; ASL: 1.10 {+-} 0.31). PET datasets of PET/MR and PET/CT offered comparable tumor delineation with [{sup 11}C]-methionine; additional lesions were found in 2/8 [{sup 68}Ga]-DOTATOC-PET in the PET/MR. Mean asymmetry index revealed a high accordance between PET/MR and PET/CT (1.5 {+-} 2.2% vs. 0.9 {+-} 3.6%; mean ratio (frontal/parieto-occipital) 0.93 {+-} 0.08 vs. 0.96 {+-} 0.05), respectively. Conclusions: The hybrid BrainPET/MR allows for molecular, anatomical and functional imaging with uncompromised MR image quality and a high accordance

  2. Evaluation of the Current State of Integrated Water Quality Modelling

    Science.gov (United States)

    Arhonditsis, G. B.; Wellen, C. C.; Ecological Modelling Laboratory

    2010-12-01

    Environmental policy and management implementation require robust methods for assessing the contribution of various point and non-point pollution sources to water quality problems as well as methods for estimating the expected and achieved compliance with the water quality goals. Water quality models have been widely used for creating the scientific basis for management decisions by providing a predictive link between restoration actions and ecosystem response. Modelling water quality and nutrient transport is challenging due a number of constraints associated with the input data and existing knowledge gaps related to the mathematical description of landscape and in-stream biogeochemical processes. While enormous effort has been invested to make watershed models process-based and spatially-distributed, there has not been a comprehensive meta-analysis of model credibility in watershed modelling literature. In this study, we evaluate the current state of integrated water quality modeling across the range of temporal and spatial scales typically utilized. We address several common modeling questions by providing a quantitative assessment of model performance and by assessing how model performance depends on model development. The data compiled represent a heterogeneous group of modeling studies, especially with respect to complexity, spatial and temporal scales and model development objectives. Beginning from 1992, the year when Beven and Binley published their seminal paper on uncertainty analysis in hydrological modelling, and ending in 2009, we selected over 150 papers fitting a number of criteria. These criteria involved publications that: (i) employed distributed or semi-distributed modelling approaches; (ii) provided predictions on flow and nutrient concentration state variables; and (iii) reported fit to measured data. Model performance was quantified with the Nash-Sutcliffe Efficiency, the relative error, and the coefficient of determination. Further, our

  3. "Liquid-liquid-solid"-type superoleophobic surfaces to pattern polymeric semiconductors towards high-quality organic field-effect transistors.

    Science.gov (United States)

    Wu, Yuchen; Su, Bin; Jiang, Lei; Heeger, Alan J

    2013-12-03

    Precisely aligned organic-liquid-soluble semiconductor microwire arrays have been fabricated by "liquid-liquid-solid" type superoleophobic surfaces directed fluid drying. Aligned organic 1D micro-architectures can be built as high-quality organic field-effect transistors with high mobilities of >10 cm(2) ·V(-1) ·s(-1) and current on/off ratio of more than 10(6) . All these studies will boost the development of 1D microstructures of organic semiconductor materials for potential application in organic electronics. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Optimization of nitridation conditions for high quality inter-polysilicon dielectric layers

    NARCIS (Netherlands)

    Klootwijk, J.H.; Bergveld, H.J.; van Kranenburg, H.; Woerlee, P.H.; Wallinga, Hans

    1996-01-01

    Nitridation of deposited high temperature oxides (HTO) was studied to form high quality inter-polysilicon dielectric layers for embedded non volatile memories. Good quality dielectric layers were obtained earlier by using an optimized deposition of polysilicon and by performing a post-dielectric

  5. Enhanced Power Quality and Minimized Peak Current Control in An Inverter based Microgrid under Unbalanced Grid Faults

    DEFF Research Database (Denmark)

    Liu, Wenzhao; Guo, Xiaoqiang; Sulligoi, Giorgio

    2016-01-01

    The microgrid inverter experiences the power oscillations and current harmonics in case of the unbalanced grid voltage faults. However, there is a trade-off between power oscillations and current harmonics should be considered in three phase three wire inverter systems during the conventional fault...... ride through control. In order to solve this problem, a novel control strategy is proposed to enhance the output current quality while mitigating the active and reactive output power oscillations. Moreover, a simple current-limited control strategy can be achieved without the necessity of the voltage....../current positive/negative sequence extraction. Finally, the simulation tests of the conventional and proposed control solutions are carried out. The results verify the effectiveness of the proposed strategy....

  6. Best practice in English Local Air Quality Management: principles illustrated by some examples of current practice

    Energy Technology Data Exchange (ETDEWEB)

    Beattie, C.I.; Ling, K.; Longhurst, J.W.S. [Univ. of the West of England, Faculty of Applied Sciences, Bristol (GB)] [and others

    1999-07-01

    The Local Air Quality Management (LAQM) process, a holistic approach to management, is well underway in England. The process aims to tackle air pollution problems from a variety of diverse sources, operating over different time scales and spatial areas. Although technical guidance from the Government has been published over the last two years, little guidance has been available for the management aspects of the process. Arguably, the management of air quality will be the crucial test of the LAQM process. Only by collaboration can technologies and policy actions, such as traffic management schemes, be put into effective action. The authors present an overview of the process, including a model of current LAQM procedures in the UK. Current practice is illustrated by way of results from a questionnaire survey of local authorities, health authorities and the Environment Agency and also by reference to specific examples from local authorities. (Author)

  7. Producing high-quality slash pine seeds

    Science.gov (United States)

    James Barnett; Sue Varela

    2003-01-01

    Slash pine is a desirable species. It serves many purposes and is well adapted to poorly drained flatwoods and seasonally flooded areas along the lower Coastal Plain of the Southeastern US. The use of high-quality seeds has been shown to produce uniform seedlings for outplanting, which is key to silvicultural success along the Coastal Plain and elsewhere. We present...

  8. High-current Rhodotron for X-ray facility

    International Nuclear Information System (INIS)

    Umezu, Toru; Tsujiura, Yuichiro; Bol, Jean Louis

    2009-01-01

    The Rhodotron is a widely employed high-power industrial accelerator developed and exclusively distributed by IBA. Most early examples of the accelerator were optimized to operate at 10 MeV. A new Rhodotron configuration recently advanced produces a lower-energy higher-current beam dedicated with x-ray to sterilize and enhancement materials. Core elements of this system's evolution include a higher performance RF electron gun (operating range, response control, and cathode lifetime). This operational machine is now producing 100 mA at 7 MeV (700 kW of beam) and treat medical devices, thick cable and pipes with a high efficiency. (author)

  9. Charged current weak interactions at high energy

    International Nuclear Information System (INIS)

    Cline, D.

    1977-01-01

    We review high energy neutrino and antineutrino charged current interactions. An overview of the experimental data is given, including a discussion of the experimental status of the y anomaly. Locality tests, μ-e universality and charge symmetry invariance tests are discussed. Charm production is discussed. The experimental status of trimuon events and possible phenomenological models for these events are presented. (orig.) [de

  10. Ion beams from high-current PF facilities

    Energy Technology Data Exchange (ETDEWEB)

    Sadowski, M [Soltan Inst. for Nuclear Studies, Otwock-Swierk (Poland)

    1997-12-31

    Pulsed beams of fast deuterons and impurity or admixture ions emitted from high-current PF-type facilities operated in different laboratories are dealt with. A short comparative analysis of time-integrated and time-resolved studies is presented. Particular attention is paid to the microstructure of such ion beams, and to the verification of some theoretical models. (author). 5 figs., 19 refs.

  11. A High-Current, Stable Nonaqueous Organic Redox Flow Battery

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Xiaoliang; Duan, Wentao; Huang, Jinhua; Zhang, Lu; Li, Bin; Reed, David; Xu, Wu; Sprenkle, Vincent; Wang, Wei

    2016-10-14

    Nonaqueous redox flow batteries are promising in pursuit of high-energy storage systems owing to the broad voltage window, but currently are facing key challenges such as poor cycling stability and lack of suitable membranes. Here we report a new nonaqueous all-organic flow chemistry that demonstrates an outstanding cell cycling stability primarily because of high chemical persistency of the organic radical redox species and their good compatibility with the supporting electrolyte. A feasibility study shows that Daramic® and Celgard® porous separators can lead to high cell conductivity in flow cells thus producing remarkable cell efficiency and material utilization even at high current operations. This result suggests that the thickness and pore size are the key performance-determining factors for porous separators. With the greatly improved flow cell performance, this new flow system largely addresses the above mentioned challenges and the findings may greatly expedite the development of durable nonaqueous flow batteries.

  12. A vacuum sealed high emission current and transmission efficiency carbon nanotube triode

    Energy Technology Data Exchange (ETDEWEB)

    Di, Yunsong [School of Electronic Science & Engineering, Southeast University, Nanjing 210096 (China); Jiangsu Key Laboratory of Optoelectronic Technology, Nanjing Normal University, Nanjing 210023 (China); Wang, Qilong; Zhang, Xiaobing, E-mail: bell@seu.edu.cn; Lei, Wei; Du, Xiaofei; Yu, Cairu [School of Electronic Science & Engineering, Southeast University, Nanjing 210096 (China)

    2016-04-15

    A vacuum sealed carbon nanotubes (CNTs) triode with a concave and spoke-shaped Mo grid is presented. Due to the high aperture ratio of the grid, the emission current could be modulated at a relatively high electric field. Totally 75 mA emission current has been obtained from the CNTs cathode with the average applied field by the grid shifting from 8 to 13 V/μm. Whilst with the electron transmission efficiency of the grid over 56%, a remarkable high modulated current electron beam over 42 mA has been collected by the anode. Also contributed by the high aperture ration of the grid, desorbed gas molecules could flow away from the emission area rapidly when the triode has been operated at a relative high emission current, and finally collected by a vacion pump. The working pressure has been maintained at ∼1 × 10{sup −7} Torr, seldom spark phenomena occurred. Nearly perfect I-V curve and corresponding Fowler-Nordheim (FN) plot confirmed the accuracy of the measured data, and the emission current was long term stable and reproducible. Thusly, this kind of triode would be used as a high-power electron source.

  13. Highly sensitive detection of a current ripple

    International Nuclear Information System (INIS)

    Aoki, Takashi; Gushiken, Tutomu; Nishikigouri, Kazutaka; Kumada, Masayuki.

    1996-01-01

    In the HIMAC, there are six thyristor-controlled power sources for driving two synchrotrons. These power sources are the three-output terminal power sources which are equipped with positive output, negative output and neutral point for the common mode countermeasures. As electromagnet circuits are connected to the three-output terminal power sources, those are three-line type. In the inside of the power source circuits controlled by thyristors, there is the oscillation peculiar to the power sources, and the variation of voltage induces current spikes. This time, in order to assess the results of the common mode countermeasures in the power source and electromagnet circuits, as one method of cross-check, it is considered that since electromagnet current flows being divided to the bridging resistance and the coil, if attention is paid to the current on bridging resistance side, the ripple components of common mode and normal mode can be detected with high sensitivity, and this was verified. The present state of heightening the performance of synchrotron power sources is explained. The cross-check of the method of assessing the performance of electromagnet power sources is reported. The method of measuring ripple current and the results of the measurement are reported. (K.I.)

  14. Current quality assurance concepts and considerations for quality control of in-clinic biochemistry testing.

    Science.gov (United States)

    Lester, Sally; Harr, K E; Rishniw, Mark; Pion, Paul

    2013-01-15

    Quality assurance is an implied concept inherent in every consumer's purchase of a product or service. In laboratory testing, quality assurance encompasses preanalytic (sampling, transport, and handling prior to testing), analytic (measurement), and postanalytic (reporting and interpretation) factors. Quality-assurance programs require that procedures are in place to detect errors in all 3 components and that the procedures are characterized by both documentation and correction of errors. There are regulatory bodies that provide mandatory standards for and regulation of human medical laboratories. No such regulations exist for veterinary laboratory testing. The American Society for Veterinary Clinical Pathology (ASVCP) Quality Assurance and Laboratory Standards Committee was formed in 1996 in response to concerns of ASVCP members about quality assurance and quality control in laboratories performing veterinary testing. Guidelines for veterinary laboratory testing have been developed by the ASVCP. The purpose of this report was to provide an overview of selected quality-assurance concepts and to provide recommendations for quality control for in-clinic biochemistry testing in general veterinary practice.

  15. Breeding and maintaining high-quality insects

    DEFF Research Database (Denmark)

    Jensen, Kim; Kristensen, Torsten Nygård; Heckmann, Lars-Henrik

    2017-01-01

    Insects have a large potential for sustainably enhancing global food and feed production, and commercial insect production is a rising industry of high economic value. Insects suitable for production typically have fast growth, short generation time, efficient nutrient utilization, high...... reproductive potential, and thrive at high density. Insects may cost-efficiently convert agricultural and industrial food by-products into valuable protein once the technology is finetuned. However, since insect mass production is a new industry, the technology needed to efficiently farm these animals is still...... in a starting phase. Here, we discuss the challenges and precautions that need to be considered when breeding and maintaining high-quality insect populations for food and feed. This involves techniques typically used in domestic animal breeding programs including maintaining genetically healthy populations...

  16. Relationship between Tree Value, Diameter, and Age in High-Quality Sugar Maple (Acer saccharum) on the Menominee Reservation, Wisconsin

    Science.gov (United States)

    Daniel C. Dey; John Dwyer; Jan Wiedenbeck

    2017-01-01

    Guidelines for managing sugar maple-dominated forests by the single-tree selection method are well established and widely adopted. The forests of the Menominee Tribe in Wisconsin provide an opportunity to validate current guidelines by testing tree value and size/age relationships in forests that have substantially older and larger high-quality trees than can be found...

  17. Electronic Current Transducer (ECT) for high voltage dc lines

    Science.gov (United States)

    Houston, J. M.; Peters, P. H., Jr.; Summerayes, H. R., Jr.; Carlson, G. J.; Itani, A. M.

    1980-02-01

    The development of a bipolar electronic current transducer (ECT) for measuring the current in a high voltage dc (HVDC) power line at line potential is discussed. The design and construction of a free standing ECT for use on a 400 kV line having a nominal line current of 2000 A is described. Line current is measured by a 0.0001 ohm shunt whose voltage output is sampled by a 14 bit digital data link. The high voltage interface between line and ground is traversed by optical fibers which carry digital light signals as far as 300 m to a control room where the digital signal is converted back to an analog representation of the shunt voltage. Two redundant electronic and optical data links are used in the prototype. Power to operate digital and optical electronics and temperature controlling heaters at the line is supplied by a resistively and capacitively graded 10 stage cascade of ferrite core transformers located inside the hollow, SF6 filled, porcelain support insulator. The cascade is driven by a silicon controlled rectifier inverter which supplies about 100 W of power at 30 kHz.

  18. Quality does not sell itself

    DEFF Research Database (Denmark)

    Giacalone, Davide; Fosgaard, Toke Reinholt; Steen, Ida

    2016-01-01

    the identification task were also significantly more likely to prefer the high quality sample. This tentatively suggests that better sensory expertise is correlated with a preference for higher quality, though future studies are needed to confirm the correctedness of this interpretation. Originality/value This work...... expensive one. Findings The results showed that preferences were equally distributed among the high and low quality samples, and that consumers did not perform better than chance level in the identification task. These results suggest that current grading systems used in the industry may be poorly...

  19. High Quality Virtual Reality for Architectural Exhibitions

    DEFF Research Database (Denmark)

    Kreutzberg, Anette

    2016-01-01

    This paper will summarise the findings from creating and implementing a visually high quality Virtual Reality (VR) experiment as part of an international architecture exhibition. It was the aim to represent the architectural spatial qualities as well as the atmosphere created from combining natural...... and artificial lighting in a prominent not yet built project. The outcome is twofold: Findings concerning the integration of VR in an exhibition space and findings concerning the experience of the virtual space itself. In the exhibition, an important aspect was the unmanned exhibition space, requiring the VR...... experience to be self-explanatory. Observations of different visitor reactions to the unmanned VR experience compared with visitor reactions at guided tours with personal instructions are evaluated. Data on perception of realism, spatial quality and light in the VR model were collected with qualitative...

  20. High-quality remote interactive imaging in the operating theatre

    Science.gov (United States)

    Grimstead, Ian J.; Avis, Nick J.; Evans, Peter L.; Bocca, Alan

    2009-02-01

    We present a high-quality display system that enables the remote access within an operating theatre of high-end medical imaging and surgical planning software. Currently, surgeons often use printouts from such software for reference during surgery; our system enables surgeons to access and review patient data in a sterile environment, viewing real-time renderings of MRI & CT data as required. Once calibrated, our system displays shades of grey in Operating Room lighting conditions (removing any gamma correction artefacts). Our system does not require any expensive display hardware, is unobtrusive to the remote workstation and works with any application without requiring additional software licenses. To extend the native 256 levels of grey supported by a standard LCD monitor, we have used the concept of "PseudoGrey" where slightly off-white shades of grey are used to extend the intensity range from 256 to 1,785 shades of grey. Remote access is facilitated by a customized version of UltraVNC, which corrects remote shades of grey for display in the Operating Room. The system is successfully deployed at Morriston Hospital, Swansea, UK, and is in daily use during Maxillofacial surgery. More formal user trials and quantitative assessments are being planned for the future.

  1. Indoor environmental quality and ventilation in U.S. office buildings: A view of current issues

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, W.J.

    1994-11-01

    Much of the current focus on indoor environmental quality and ventilation in US office buildings is a response to sick building syndrome and occupant complaints about building-related health symptoms, poor indoor air quality, and thermal discomfort. The authors know that serious ``sick-building`` problems occur in a significant number of US office buildings and that a significant proportion of the occupants in many normal (non-sick) buildings report building-related health symptoms. Concerns about the health effects of environmental tobacco smoke have also focused attention on the indoor environment. The major responses of industry and governments, underway at the present time, are to restrict smoking in offices, to attempt to reduce the emissions of indoor pollutants, and to improve the operation of heating, ventilating and air conditioning (HVAC) systems. Better air filtration, improved HVAC commissioning and maintenance, and increased provisions for individual control of HVAC are some of the improvements in HVAC that are currently being, evaluated. In the future, the potential for improved productivity and reduced airborne transmission of infectious disease may become the major driving force for improved indoor environments.

  2. Sexuality Education and Implications for Quality of Care for Individuals with Adult Onset Disability: A Review of Current Literature

    Science.gov (United States)

    Eglseder, Kate; Webb, Sheridan

    2017-01-01

    Purpose: To investigate the need for sexuality education for individuals with adult onset physical disabilities as it relates to quality of life and to identify current trends in the provision of sexuality education by health care providers relating to quality of care. Data Sources: Literature review from January 1986 to December 2016. Study…

  3. Motion-induced eddy current thermography for high-speed inspection

    Directory of Open Access Journals (Sweden)

    Jianbo Wu

    2017-08-01

    Full Text Available This letter proposes a novel motion-induced eddy current based thermography (MIECT for high-speed inspection. In contrast to conventional eddy current thermography (ECT based on a time-varying magnetic field created by an AC coil, the motion-induced eddy current is induced by the relative motion between magnetic field and inspected objects. A rotating magnetic field created by three-phase windings is used to investigate the heating principle and feasibility of the proposed method. Firstly, based on Faraday’s law the distribution of MIEC is investigated, which is then validated by numerical simulation. Further, experimental studies are conducted to validate the proposed method by creating rotating magnetic fields at different speeds from 600 rpm to 6000 rpm, and it is verified that rotating speed will increase MIEC intensity and thereafter improve the heating efficiency. The conclusion can be preliminarily drawn that the proposed MIECT is a platform suitable for high-speed inspection.

  4. Modeling of leakage currents in high-k dielectrics

    International Nuclear Information System (INIS)

    Jegert, Gunther Christian

    2012-01-01

    Leakage currents are one of the major bottlenecks impeding the downscaling efforts of the semiconductor industry. Two core devices of integrated circuits, the transistor and, especially, the DRAM storage capacitor, suffer from the increasing loss currents. In this perspective a fundamental understanding of the physical origin of these leakage currents is highly desirable. However, the complexity of the involved transport phenomena so far has prevented the development of microscopic models. Instead, the analysis of transport through the ultra-thin layers of high-permittivity (high-k) dielectrics, which are employed as insulating layers, was carried out at an empirical level using simple compact models. Unfortunately, these offer only limited insight into the physics involved on the microscale. In this context the present work was initialized in order to establish a framework of microscopic physical models that allow a fundamental description of the transport processes relevant in high-k thin films. A simulation tool that makes use of kinetic Monte Carlo techniques was developed for this purpose embedding the above models in an environment that allows qualitative and quantitative analyses of the electronic transport in such films. Existing continuum approaches, which tend to conceal the important physics behind phenomenological fitting parameters, were replaced by three-dimensional transport simulations at the level of single charge carriers. Spatially localized phenomena, such as percolation of charge carriers across pointlike defects, being subject to structural relaxation processes, or electrode roughness effects, could be investigated in this simulation scheme. Stepwise a self-consistent, closed transport model for the TiN/ZrO 2 material system, which is of outmost importance for the semiconductor industry, was developed. Based on this model viable strategies for the optimization of TiN/ZrO 2 /TiN capacitor structures were suggested and problem areas that may

  5. Modeling of leakage currents in high-k dielectrics

    Energy Technology Data Exchange (ETDEWEB)

    Jegert, Gunther Christian

    2012-03-15

    Leakage currents are one of the major bottlenecks impeding the downscaling efforts of the semiconductor industry. Two core devices of integrated circuits, the transistor and, especially, the DRAM storage capacitor, suffer from the increasing loss currents. In this perspective a fundamental understanding of the physical origin of these leakage currents is highly desirable. However, the complexity of the involved transport phenomena so far has prevented the development of microscopic models. Instead, the analysis of transport through the ultra-thin layers of high-permittivity (high-k) dielectrics, which are employed as insulating layers, was carried out at an empirical level using simple compact models. Unfortunately, these offer only limited insight into the physics involved on the microscale. In this context the present work was initialized in order to establish a framework of microscopic physical models that allow a fundamental description of the transport processes relevant in high-k thin films. A simulation tool that makes use of kinetic Monte Carlo techniques was developed for this purpose embedding the above models in an environment that allows qualitative and quantitative analyses of the electronic transport in such films. Existing continuum approaches, which tend to conceal the important physics behind phenomenological fitting parameters, were replaced by three-dimensional transport simulations at the level of single charge carriers. Spatially localized phenomena, such as percolation of charge carriers across pointlike defects, being subject to structural relaxation processes, or electrode roughness effects, could be investigated in this simulation scheme. Stepwise a self-consistent, closed transport model for the TiN/ZrO{sub 2} material system, which is of outmost importance for the semiconductor industry, was developed. Based on this model viable strategies for the optimization of TiN/ZrO{sub 2}/TiN capacitor structures were suggested and problem areas

  6. HOM frequency control of SRF cavity in high current ERLs

    Science.gov (United States)

    Xu, Chen; Ben-Zvi, Ilan

    2018-03-01

    The acceleration of high-current beam in Superconducting Radio Frequency (SRF) cavities is a challenging but essential for a variety of advanced accelerators. SRF cavities should be carefully designed to minimize the High Order Modes (HOM) power generated in the cavities by the beam current. The reduction of HOM power we demonstrate in a particular case can be quite large. This paper presents a method to systematically control the HOM resonance frequencies in the initial design phase to minimize the HOM power generation. This method is expected to be beneficial for the design of high SRF cavities addressing a variety of Energy Recovery Linac (ERL) applications.

  7. Critical current of high Tc superconducting Bi223/Ag tapes

    NARCIS (Netherlands)

    Huang, Y.; ten Haken, Bernard; ten Kate, Herman H.J.

    1998-01-01

    The magnetic field dependence of the critical current of various high Tc superconducting Bi2223/Ag tapes indicates that the transport current is carried through two paths: one is through weakly-linked grain boundaries (Josephson junctions); another is through well-connected grains. The critical

  8. A Filtration-based Method of Preparing High-quality Nuclei from Cross-linked Skeletal Muscle for Chromatin Immunoprecipitation.

    Science.gov (United States)

    Nohara, Kazunari; Chen, Zheng; Yoo, Seung-Hee

    2017-07-06

    Chromatin immunoprecipitation (ChIP) is a powerful method to determine protein binding to chromatin DNA. Fiber-rich skeletal muscle, however, has been a challenge for ChIP due to technical difficulty in isolation of high-quality nuclei with minimal contamination of myofibrils. Previous protocols have attempted to purify nuclei before cross-linking, which incurs the risk of altered DNA-protein interaction during the prolonged nuclei preparation process. In the current protocol, we first cross-linked the skeletal muscle tissue collected from mice, and the tissues were minced and sonicated. Since we found that ultracentrifugation was not able to separate nuclei from myofibrils using cross-linked muscle tissue, we devised a sequential filtration procedure to obtain high-quality nuclei devoid of significant myofibril contamination. We subsequently prepared chromatin by using an ultrasonicator, and ChIP assays with anti-BMAL1 antibody revealed robust circadian binding pattern of BMAL1 to target gene promoters. This filtration protocol constitutes an easily applicable method to isolate high-quality nuclei from cross-linked skeletal muscle tissue, allowing consistent sample processing for circadian and other time-sensitive studies. In combination with next-generation sequencing (NGS), our method can be deployed for various mechanistic and genomic studies focusing on skeletal muscle function.

  9. High-Current-Density Vertical-Tunneling Transistors from Graphene/Highly Doped Silicon Heterostructures.

    Science.gov (United States)

    Liu, Yuan; Sheng, Jiming; Wu, Hao; He, Qiyuan; Cheng, Hung-Chieh; Shakir, Muhammad Imran; Huang, Yu; Duan, Xiangfeng

    2016-06-01

    Scalable fabrication of vertical-tunneling transistors is presented based on heterostructures formed between graphene, highly doped silicon, and its native oxide. Benefiting from the large density of states of highly doped silicon, the tunneling transistors can deliver a current density over 20 A cm(-2) . This study demonstrates that the interfacial native oxide plays a crucial role in governing the carrier transport in graphene-silicon heterostructures. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Enhanced performance of high current discharges in JET produced by ICRF heating during the current rise

    International Nuclear Information System (INIS)

    Bures, M.; Bhatnagar, V.; Christiansen, J.P.

    1989-01-01

    The performance of high current discharges can be improved by applying central ICRF heating before or shortly after the onset of sawtooth activity in the plasma current rise phase. Long sawtooth-free periods have been obtained which result in a transiently-enhanced discharge performance. High T c (0) = 9-10.5 keV with peaked profile T e (0)/ e > = 3-4 were obtained giving values of N e (0)T e (0) up to 6 x 10 20 (keV m -3 ). Improvements in T i (0) and neutron production are observed. A best value of n Dd (0)T i (0)τ E = 1.65 x 10 20 (m -3 keV s) was achieved. Local transport simulation shows that the electron and ion thermal diffusivities do not differ substantially in the two cases of current-rise (CR) and flat-top (FT) heating, the performance of the central plasma region being enhanced, in the case of current-rise, entirely by the elimination of the sawtooth instability. The maximum D-D reaction rate is enhanced by a factor of 2 compared to the flat-top value. An appreciable part of the reaction rate is attributed to 2nd harmonic deuterium (2ω CD ) heating. In all current-rise discharges radiation amounts to 25-50% of total power and Ζ eff remains roughly constant. (author)

  11. High Voltage Coil Current Sensor for DC-DC Converters Employing DDCC

    Directory of Open Access Journals (Sweden)

    M. Drinovsky

    2015-12-01

    Full Text Available Current sensor is an integral part of every switching converter. It is used for over-current protection, regulation and in case of multiphase converters for balancing. A new high voltage current sensor for coil-based current sensing in DC-DC converters is presented. The sensor employs DDCC with high voltage input stage and gain trimming. The circuit has been simulated and implemented in 0.35 um BCD technology as part of a multiphase DC-DC converter where its function has been verified. The circuit is able to sustain common mode voltage on the input up to 40 V, it occupies 0.387*0.345 mm2 and consumes 3.2 mW typically.

  12. Design and application consideration of high temperature superconducting current leads

    International Nuclear Information System (INIS)

    Wu, J.L.

    1994-01-01

    As a potential major source of heat leak and the resultant cryogen boiloff, cryogenic current leads can significantly affect the refrigeration power requirement of cryogenic power equipment. Reduction of the heat leak associated with current leads can therefore contribute to the development and application of this equipment. Recent studies and tests have demonstrated that, due to their superconducting and low thermal conductivity properties, ceramic high temperature superconductor (HTSC) can be employed in current leads to significantly reduce the heat leak. However, realization of this benefit requires special design considerations pertaining to the properties and the fabrication technology of the relatively new ceramic superconductor materials. Since processing and fabrication technology are continuously being developed in the laboratories, data on material properties unrelated to critical states are quite limited. Therefore, design analysis and experiments have to be conducted in tandem to achieve a successful development. Due to the rather unique combination of superconducting and thermal conductivities which are orders of magnitude lower than copper, ceramic superconductors allow expansion of the operating scenarios of current leads. In addition to the conventional vapor-cooled lead type application, low heat leak conduction-cooled type current leads may be practical and are being developed. Furthermore, a current lead with an intermediate heat leak intercept has been successfully demonstrated in a multiple current lead assembly employing HTSC. These design and application considerations of high temperature superconducting current leads are addressed here

  13. Rf Gun with High-Current Density Field Emission Cathode

    International Nuclear Information System (INIS)

    Jay L. Hirshfield

    2005-01-01

    High current-density field emission from an array of carbon nanotubes, with field-emission-transistor control, and with secondary electron channel multiplication in a ceramic facing structure, have been combined in a cold cathode for rf guns and diode guns. Electrodynamic and space-charge flow simulations were conducted to specify the cathode configuration and range of emission current density from the field emission cold cathode. Design of this cathode has been made for installation and testing in an existing S-band 2-1/2 cell rf gun. With emission control and modulation, and with current density in the range of 0.1-1 kA/cm2, this cathode could provide performance and long-life not enjoyed by other currently-available cathodes

  14. High-current railgap studies

    Science.gov (United States)

    Druce, R.; Gordon, L.; Hofer, W.; Wilson, M.

    1983-06-01

    Characteristics of a 40-kV, 750-kA, multichannel rail gap are presented. The gap is a three electrode, field distortion triggered design, with a total switch inductance of less than 10 nH. At maximum ratings, the gap typically switches 10 C per shot, at 700 kA, with a jitter of less than 2 ns. Channel evolution and current division were studied on image converter streak photographs. Transient gas pressure measurements were made to investigate the arc generated shocks and to detect single channel failure. Channel current sharing and simultaneity are described and their effects on the switch inductance in the channel current sharing and erosion measurements are discussed.

  15. Test quality

    International Nuclear Information System (INIS)

    Hartley, R.S.; Keller, A.E.

    1992-01-01

    This document discusses inservice testing of safety-related components at nuclear power plants which is performed under the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (the Code). Subsections IWP and IWV of Section XI of the Code state test method and frequency requirements for pumps and valves respectively. Tests vary greatly in quality and frequency. This paper explores the concept of test quality and its relationship with operational readiness and preventive maintenance. This paper also considers the frequencies of component testing. Test quality is related to a test's ability to detect degradation that can cause component failure. The quality of the test depends on several factors, including specific parameters measured, system or component conditions, and instrument accuracy. The quality of some currently required tests for check valves, motor-operated valves, and pumps is also discussed. Suggestions are made to improve test quality by measuring different parameters, testing valves under load, and testing positive displacement pumps at high pressure and centrifugal pumps at high flow rate conditions. These suggestions can help to improve the level of assurance of component operational readiness gained from testing

  16. A Steel Ball Surface Quality Inspection Method Based on a Circumferential Eddy Current Array Sensor.

    Science.gov (United States)

    Zhang, Huayu; Xie, Fengqin; Cao, Maoyong; Zhong, Mingming

    2017-07-01

    To efficiently inspect surface defects on steel ball bearings, a new method based on a circumferential eddy current array (CECA) sensor was proposed here. The best probe configuration, in terms of the coil quality factor (Q-factor), magnetic field intensity, and induced eddy current density on the surface of a sample steel ball, was determined using 3-, 4-, 5-, and 6-coil probes, for analysis and comparison. The optimal lift-off from the measured steel ball, the number of probe coils, and the frequency of excitation current suitable for steel ball inspection were obtained. Using the resulting CECA sensor to inspect 46,126 steel balls showed a miss rate of ~0.02%. The sensor was inspected for surface defects as small as 0.05 mm in width and 0.1 mm in depth.

  17. Recent DIII-D high power heating and current drive experiments

    International Nuclear Information System (INIS)

    Simonen, T.C.; Jackson, G.L.; Mahdavi, M.A.; Petrie, T.W.; Politzer, P.A.; Taylor, T.S.; Lazarus, E.A.

    1994-02-01

    This paper describes recent DIII-D high power heating and current drive experiments. Describes are experiments with improved wall conditioning, divertor particle pumping, radiative divertor experiments, studies of plasma shape and high poloidal beta

  18. Integration study of high quality teaching resources in universities

    Directory of Open Access Journals (Sweden)

    Honglu Liu

    2012-12-01

    Full Text Available Purpose: The development level and quality of education depend on the merits and efficiency in the use of teaching resources, especially in the case of obvious contradiction between the demand and supply of teaching resources. So to integrate teaching resources, improve the efficiency in the use of high quality teaching resources, and take the road of content development to enhance the competitiveness of education has become very important and urgent.Design/methodology/approach: On the basis of analysis on the teaching resources of universities and the problems they faced, this paper introduced the basic concepts of cloud storage, and built the integration architecture of high quality teaching resources in universities based on the cloud storage.Findings and Originality/value: The HDFS-based cloud storage proposed in this paper is a dynamically adjustable and Internet-based storage solution, and the users can access storage targets using the network through a common and easy-to-use protocol and application programming interfaces. This new technology is useful for end users benefits. With the continuous development and improvement of cloud storage, it will necessarily result in more and more applications in the institutions of higher learning and education network.Originality/value: This paper introduced the cloud storage into the integration of high quality teaching resources in universities first and as a new form of service, it can be a good solution.

  19. High-current railgap studies

    Energy Technology Data Exchange (ETDEWEB)

    Druce, R.; Gordon, L.; Hofer, W.; Wilson, M.

    1983-06-03

    Characteristics of a 40-kV, 750-kA, multichannel rail gap are presented. The gap is a three electrode, field-distortion-triggered design, with a total switch inductance of less than 10 nH. At maximum ratings, the gap typically switches 10 C per shot, at 700 kA, with a jitter of less than 2 ns. Image-converter streak photographs were used to study channel evolution and current division. Transient gas-pressure measurements were made to investigate the arc generated shocks and to detect single channel failure. Channel current sharing and simultaneity are described and their effects on the switch inductance and lifetime are discussed. Lifetime tests of the rail gap were performed. Degradation in the channel current-sharing and erosion measurements are discussed.

  20. Recent DIII-D high power heating and current drive experiments

    International Nuclear Information System (INIS)

    Simonen, T.C.; Jackson, G.L.; Lazarus, E.A.; Mahdavi, M.A.; Petrie, T.W.; Politzer, P.A.; Taylor, T.S.

    1995-01-01

    This paper describes recent DIII-D high power heating and current drive experiments. Described are experiments with improved wall conditioning, divertor particle pumping, radiative divertor experiments, studies of plasma shape and high poloidal β. ((orig.))

  1. Recent DIII-D high power heating and current drive experiments

    Energy Technology Data Exchange (ETDEWEB)

    Simonen, T.C. [General Atomics, San Diego, CA (United States); Jackson, G.L. [General Atomics, San Diego, CA (United States); Lazarus, E.A. [Oak Ridge National Lab., TN (United States); Mahdavi, M.A. [General Atomics, San Diego, CA (United States); Petrie, T.W. [General Atomics, San Diego, CA (United States); Politzer, P.A. [General Atomics, San Diego, CA (United States); Taylor, T.S. [General Atomics, San Diego, CA (United States); DIII-D Team

    1995-01-01

    This paper describes recent DIII-D high power heating and current drive experiments. Described are experiments with improved wall conditioning, divertor particle pumping, radiative divertor experiments, studies of plasma shape and high poloidal {beta}. ((orig.)).

  2. High-voltage direct-current circuit breakers

    International Nuclear Information System (INIS)

    Yoshioka, Y.; Hirasawa, K.

    1991-01-01

    This paper reports that in 1954 the first high-voltage direct-current (HVDC) transmission system was put into operation between Gotland and the mainland of Sweden. Its system voltage and capacity were 100 kV and 20 MW, respectively. Since then many HVDC transmission systems have been planned, constructed, or commissioned in more than 30 places worldwide, and their total capacity is close to 40 GW. Most systems commissioned to date are two-terminal schemes, and HVDC breakers are not yet used in the high-potential main circuit of those systems, because the system is expected to perform well using only converter/inverter control even at a fault stage of the transmission line. However, even in a two-terminal scheme there are not a few merits in using an HVDC breaker when the system has two parallel transmission lines, that is, when it is a double-circuit system

  3. Generation and transportation of low-energy, high-current electron beams

    International Nuclear Information System (INIS)

    Ozur, G.E.; Proskurovskij, D.I.; Nazarov, D.S.

    1996-01-01

    Experimental data on the production of low-energy, high-current electron beams in a plasma-filled diode are presented. The highest beam energy density achieved is about 40 J/cm 2 , which makes it possible to treat materials in the mode of intense evaporation of the surface layer. It was shown that the use of a hollow cathode improves the beam homogeneity. The feasibility was demonstrated of the production of low-energy high-current electron beams in a gun with plasma anode based on the use of a reflective discharge. (author). 6 figs., 6 refs

  4. Public reporting on quality, waiting times and patient experience in 11 high-income countries.

    Science.gov (United States)

    Rechel, Bernd; McKee, Martin; Haas, Marion; Marchildon, Gregory P; Bousquet, Frederic; Blümel, Miriam; Geissler, Alexander; van Ginneken, Ewout; Ashton, Toni; Saunes, Ingrid Sperre; Anell, Anders; Quentin, Wilm; Saltman, Richard; Culler, Steven; Barnes, Andrew; Palm, Willy; Nolte, Ellen

    2016-04-01

    This article maps current approaches to public reporting on waiting times, patient experience and aggregate measures of quality and safety in 11 high-income countries (Australia, Canada, England, France, Germany, Netherlands, New Zealand, Norway, Sweden, Switzerland and the United States). Using a questionnaire-based survey of key national informants, we found that the data most commonly made available to the public are on waiting times for hospital treatment, being reported for major hospitals in seven countries. Information on patient experience at hospital level is also made available in many countries, but it is not generally available in respect of primary care services. Only one of the 11 countries (England) publishes composite measures of overall quality and safety of care that allow the ranking of providers of hospital care. Similarly, the publication of information on outcomes of individual physicians remains rare. We conclude that public reporting of aggregate measures of quality and safety, as well as of outcomes of individual physicians, remain relatively uncommon. This is likely to be due to both unresolved methodological and ethical problems and concerns that public reporting may lead to unintended consequences. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  5. Stationary, high bootstrap fraction plasmas in DIII-D without inductive current control

    International Nuclear Information System (INIS)

    Politzer, P.A.; Hyatt, A.W.; Luce, T.C.; Prater, R.; Turnbull, A.D.; Ferron, J.R.; Greenfield, C.M.; La Haye, R.J.; Petty, C.C.; Perkins, F.W.; Brennan, D.P.; Lazarus, E.A.; Jayakumar, J.; Wade, M.R.

    2005-01-01

    We have initiated an experimental program to address some of the questions associated with operation of a tokamak with high bootstrap current fraction under high performance conditions, without assistance from a transformer. In these discharges stationary (or slowly improving) conditions are maintained for > 3.7 s at β N ∼ β p ≤ 3.3. The achievable current and pressure are limited by a relaxation oscillation, involving growth and collapse of an ITB at ρ ≥ 0.6. The pressure gradually increases and the current profile broadens throughout the discharge. Eventually the plasma reaches a more stable, high confinement (H89P ∼ 3) state. Characteristically these plasmas have 65%-85% bootstrap current, 15%-30% NBCD, and 0%-10% ECCD. (author)

  6. Current neutralization of nanosecond risetime, high-current electron beam

    International Nuclear Information System (INIS)

    Lidestri, J.P.; Spence, P.W.; Bailey, V.L.; Putnam, S.D.; Fockler, J.; Eichenberger, C.; Champney, P.D.

    1991-01-01

    This paper reports that the authors have recently investigated methods to achieve current neutralization in fast risetime (<3 ns) electron beams propagating in low-pressure gas. For this investigation, they injected a 3-MV, 30-kA intense beam into a drift cell containing gas pressures from 0.10 to 20 torr. By using a fast net current monitor (100-ps risetime), it was possible to observe beam front gas breakdown phenomena and to optimize the drift cell gas pressure to achieve maximum current neutralization. Experimental observations have shown that by increasing the drift gas pressure (P ∼ 12.5 torr) to decrease the mean time between secondary electron/gas collisions, the beam can propagate with 90% current neutralization for the full beam pulsewidth (16 ns)

  7. HIGH-CURRENT COLD CATHODE FIELD EMISSION ARRAY FOR ELECTRON LENS APPLICATION

    Energy Technology Data Exchange (ETDEWEB)

    Hirshfield, Jay L

    2012-12-28

    During Phase I, the following goals were achieved: (1) design and fabrication of a novel, nano-dimensional CNT field emitter assembly for high current density application, with high durability; (2) fabrication of a ceramic based micro channel plate (MCP) and characterization of its secondary electron emission; and (3) characterizing the CNT/MCP cathode for high field emission and durability. As a result of these achievements, a relatively high current density of ~ 1.2 A/cm2 from a CNT cathode and single channel MCP were measured. The emission current was also extremely stable with a peak-to-peak variation of only 1.8%. The emission current could be further enhanced to meet requirements for electron lens applications by increasing the number of MCP channels. A calculation for maximum possible current density with a 1200 channel/cm2 MCP, placed over a cathode with 1200 uniformly functioning CNTs, would be ~1.46 kA/cm2, neglecting space charge limitations. Clearly this level of emission is far greater than what is needed for the electron lens application, but it does offer a highly comforting margin to account for sub-standard emitters and/or to allow the lesser challenge of building a cathode with fewer channels/cm2. A satisfactory goal for the electron lens application would be a controllable emission of 2-4 mA per channel in an ensemble of 800-1200 uniformly-functioning channels/cm2, and a cathode with overall area of about 1 cm2.

  8. Application of RF Superconductivity to High-Current Linac

    International Nuclear Information System (INIS)

    Chan, K.C.D.

    1998-01-01

    In 1997, the authors initiated a development program in Los Alamos for high-current superconducting proton-linac technology to build prototypes components of this linac to demonstrate the feasibility. The authors are building 700-MHz niobium cavities with elliptical shapes, as well as power couplers to transfer high RF power to these cavities. The cavities and power couplers will be integrated in cryostats as linac cryomodules. In this paper, they describe the linac design and the status of the development program

  9. High dislocation density of tin induced by electric current

    International Nuclear Information System (INIS)

    Liao, Yi-Han; Liang, Chien-Lung; Lin, Kwang-Lung; Wu, Albert T.

    2015-01-01

    A dislocation density of as high as 10 17 /m 2 in a tin strip, as revealed by high resolution transmission electron microscope, was induced by current stressing at 6.5 x 10 3 A/ cm 2 . The dislocations exist in terms of dislocation line, dislocation loop, and dislocation aggregates. Electron Backscattered Diffraction images reflect that the high dislocation density induced the formation of low deflection angle subgrains, high deflection angle Widmanstätten grains, and recrystallization. The recrystallization gave rise to grain refining

  10. Nuclear Medicine Technologists' Perception and Current Assessment of Quality: A Society of Nuclear Medicine and Molecular Imaging Technologist Section Survey.

    Science.gov (United States)

    Mann, April; Farrell, Mary Beth; Williams, Jessica; Basso, Danny

    2017-06-01

    In 2015, the Society of Nuclear Medicine and Molecular Imaging Technologist Section (SNMMI-TS) launched a multiyear quality initiative to help prepare the technologist workforce for an evidence-based health-care delivery system that focuses on quality. To best implement the quality strategy, the SNMMI-TS first surveyed technologists to ascertain their perception of quality and current measurement of quality indicators. Methods: An internet survey was sent to 27,989 e-mail contacts. Questions related to demographic data, perceptions of quality, quality measurement, and opinions on the minimum level of education are discussed in this article. Results: A total of 4,007 (14.3%) responses were received. When asked to list 3 words or phrases that represent quality, there were a plethora of different responses. The top 3 responses were image quality, quality control, and technologist education or competency. Surveying patient satisfaction was the most common quality measure (80.9%), followed by evaluation of image quality (78.2%). Evaluation of image quality (90.3%) and equipment functionality (89.4%) were considered the most effective measures. Technologists' differentiation between quality, quality improvement, quality control, quality assurance, and quality assessment seemed ambiguous. Respondents were confident in their ability to assess and improve quality at their workplace (91.9%) and agreed their colleagues were committed to delivering quality work. Of note, 70.7% of respondents believed that quality is directly related to the technologist's level of education. Correspondingly, respondents felt there should be a minimum level of education (99.5%) and that certification or registry should be required (74.4%). Most respondents (59.6%) felt that a Bachelor's degree should be the minimum level of education, followed by an Associate's degree (40.4%). Conclusion: To best help nuclear medicine technologists provide quality care, the SNMMI-TS queried technologists to

  11. A high linearity current mode multiplier/divider with a wide dynamic range

    International Nuclear Information System (INIS)

    Liao Pengfei; Luo Ping; Zhang Bo; Li Zhaoji

    2012-01-01

    A high linearity current mode multiplier/divider (CMM/D) with a wide dynamic range is presented. The proposed CMM/D is based on the voltage—current characteristic of the diode, thus wide dynamic range is achieved. In addition, high linearity is achieved because high accuracy current mirrors are adopted and the output current is insensitive to the temperature and device parameters of the fabrication process. Furthermore, no extra bias current for all input signals is required and thus power saving is realized. With proper selection of establishing the input terminal, the proposed circuit can perform as a multifunction circuit to be operated as a multiplier/divider, without changing its topology. The proposed circuit is implemented in a 0.25 μm BCD process and the chip area is 0.26 × 0.24 mm 2 . The simulation and measurement results show that the maximum static linearity error is ±1.8% and the total harmonic distortion is 0.4% while the input current ranges from 0 to 200 μA. (semiconductor integrated circuits)

  12. Versatile high current metal ion implantation facility

    International Nuclear Information System (INIS)

    Brown, I.G.; Dickinson, M.R.; Galvin, J.E.; Godechot, X.; MacGill, R.A.

    1992-01-01

    A metal ion implantation facility has been developed with which high current beams of practically all the solid metals of the periodic table can be produced. A multicathode, broad-beam, metal vapor vacuum arc ion source is used to produce repetitively pulsed metal ion beams at an extraction voltage of up to 100 kV, corresponding to an ion energy of up to several hundred kiloelectronvolts because of the ion charge state multiplicity, and with a beam current of up to several amps peak pulsed and several tens of milliamps time averaged delivered onto a downstream target. Implantation is done in a broad-beam mode, with a direct line of sight from ion source to target. Here we summarize some of the features of the ion source and the implantation facility that has been built up around it. (orig)

  13. Progress Toward Steady State Tokamak Operation Exploiting the high bootstrap current fraction regime

    Science.gov (United States)

    Ren, Q.

    2015-11-01

    Recent DIII-D experiments have advanced the normalized fusion performance of the high bootstrap current fraction tokamak regime toward reactor-relevant steady state operation. The experiments, conducted by a joint team of researchers from the DIII-D and EAST tokamaks, developed a fully noninductive scenario that could be extended on EAST to a demonstration of long pulse steady-state tokamak operation. Fully noninductive plasmas with extremely high values of the poloidal beta, βp >= 4 , have been sustained at βT >= 2 % for long durations with excellent energy confinement quality (H98y,2 >= 1 . 5) and internal transport barriers (ITBs) generated at large minor radius (>= 0 . 6) in all channels (Te, Ti, ne, VTf). Large bootstrap fraction (fBS ~ 80 %) has been obtained with high βp. ITBs have been shown to be compatible with steady state operation. Because of the unusually large ITB radius, normalized pressure is not limited to low βN values by internal ITB-driven modes. βN up to ~4.3 has been obtained by optimizing the plasma-wall distance. The scenario is robust against several variations, including replacing some on-axis with off-axis neutral beam injection (NBI), adding electron cyclotron (EC) heating, and reducing the NBI torque by a factor of 2. This latter observation is particularly promising for extension of the scenario to EAST, where maximum power is obtained with balanced NBI injection, and to a reactor, expected to have low rotation. However, modeling of this regime has provided new challenges to state-of-the-art modeling capabilities: quasilinear models can dramatically underpredict the electron transport, and the Sauter bootstrap current can be insufficient. The analysis shows first-principle NEO is in good agreement with experiments for the bootstrap current calculation and ETG modes with a larger saturated amplitude or EM modes may provide the missing electron transport. Work supported in part by the US DOE under DE-FC02-04ER54698, DE-AC52-07NA

  14. Student Engagement in the Scottish Quality Enhancement Framework

    Science.gov (United States)

    Gvaramadze, Irakli

    2011-01-01

    The research addressed the interplay of student engagement and quality enhancement mechanisms in the Scottish higher education system. The paper demonstrates increasing focus on student learning, learning experience and high-quality learning in the current quality enhancement approaches. The student-university coproduction model is used to…

  15. Development of accounting quality management system

    Directory of Open Access Journals (Sweden)

    Plakhtii T.F.

    2017-08-01

    Full Text Available Accounting organization as one of the types of practical activities at the enterprise involves organization of the process of implementation of various kinds of accounting procedures to ensure meeting needs of the users of accounting information. Therefore, to improve its quality an owner should use tools, methods and procedures that enable to improve the quality of implementation of accounting methods and technology. The necessity of using a quality management system for the improvement of accounting organization at the enterprise is substantiated. The system of accounting quality management is developed and grounded in the context of ISO 9001:2015, which includes such processes as the processes of the accounting system, leadership, planning, and evaluation. On the basis of specification and justification of the set of universal requirements (content requirements, formal requirements the model of the environment of demands for high-quality organization of the computerized accounting system that improves the process of preparing high quality financial statements is developed. In order to improve the system of accounting quality management, to justify the main objectives of its further development, namely elimination of unnecessary characteristics of accounting information, the differences between the current level of accounting information quality and its perfect level are considered; the meeting of new needs of users of accounting information that have not been satisfied yet. The ways of leadership demonstration in the system of accounting quality management of accounting subjects at the enterprise are substantiated. The relationship between the current level of accounting information quality and its perfect level is considered. The possible types of measures aimed at improving the system of accounting quality management are identified. The paper grounds the need to include the principle of proper management in the current set of accounting

  16. Combined microfluidization and ultrasonication: a synergistic protocol for high-efficient processing of SWCNT dispersions with high quality

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Sida, E-mail: s.luo@buaa.edu.cn [Beihang University, School of Mechanical Engineering and Automation (China); Liu, Tao, E-mail: tliu@fsu.edu [Florida State University, High-Performance Materials Institute (United States); Wang, Yong; Li, Liuhe [Beihang University, School of Mechanical Engineering and Automation (China); Wang, Guantao; Luo, Yun [China University of Geosciences, Center of Safety Research, School of Engineering and Technology (China)

    2016-08-15

    High-efficient and large-scale production of high-quality CNT dispersions is necessary for meeting the future needs to develop various CNT-based electronic devices. Herein, we have designed novel processing protocols by combining conventional ultrasonication process with a new microfluidization technique to produce high-quality SWCNT dispersions with improved processing efficiency. To judge the quality of SWCNT dispersions, one critical factor is the degree of exfoliation, which could be quantified by both geometrical dimension of the exfoliated nanotubes and percentage of individual tubes in a given dispersion. In this paper, the synergistic effect of the combined protocols was systematically investigated through evaluating SWCNT dispersions with newly developed characterization techniques, namely preparative ultracentrifuge method (PUM) and simultaneous Raman scattering and photoluminescence spectroscopy (SRSPL). The results of both techniques draw similar conclusions that as compared with either of the processes operated separately, a low-pass microfluidization followed by a reasonable duration of ultrasonication could substantially improve the processing efficiency to produce high-quality SWCNT dispersions with averaged particle length and diameter as small as ~600 and ~2 nm, respectively.Graphical abstract.

  17. Compilation of current high energy physics experiments

    International Nuclear Information System (INIS)

    1978-09-01

    This compilation of current high-energy physics experiments is a collaborative effort of the Berkeley Particle Data Group, the SLAC library, and the nine participating laboratories: Argonne (ANL), Brookhaven (BNL), CERN, DESY, Fermilab (FNAL), KEK, Rutherford (RHEL), Serpukhov (SERP), and SLAC. Nominally, the compilation includes summaries of all high-energy physics experiments at the above laboratories that were approved (and not subsequently withdrawn) before about June 1978, and had not completed taking of data by 1 January 1975. The experimental summaries are supplemented with three indexes to the compilation, several vocabulary lists giving names or abbreviations used, and a short summary of the beams at each of the laboratories (except Rutherford). The summaries themselves are included on microfiche

  18. High current capacity electrical connector

    International Nuclear Information System (INIS)

    Bettis, E.S.; Watts, H.L.

    1976-01-01

    An electrical connector is provided for coupling high current capacity electrical conductors such as copper busses or the like. The connector is arranged in a ''sandwiched'' configuration in which a conductor plate contacts the busses along major surfaces clamped between two stainless steel backing plates. The conductor plate is provided with contact buttons in a spaced array such that the caps of the buttons extend above the conductor plate surface to contact the busses. When clamping bolts provided through openings in the sandwiched arrangement are tightened, Belleville springs provided under the rim of each button cap are compressed and resiliently force the caps into contact with the busses' contacting surfaces to maintain a predetermined electrical contact area provided by the button cap tops. The contact area does not change with changing thermal or mechanical stresses applied to the coupled conductors

  19. Stability of large orbit, high-current particle rings

    International Nuclear Information System (INIS)

    Lovelace, R.V.E.

    1994-01-01

    A review is made of theory of the low-frequency stability of large orbit, high-current particle rings which continue to be of interest for compact fusion systems. The precession mode was the first mode predicted by Furth and observed by Christofilos to be unstable under certain conditions. Subsequently, many detailed studies have been made of the stability of particle rings- different modes, different ring geometries, systems with/without a toroidal B field, and sytems with/without a current carrying plasma component. The possibly dangerous modes are still thought to include the precession mode, the tilting mode, and the low order kink modes. copyright American Institute of Physics

  20. A Steel Ball Surface Quality Inspection Method Based on a Circumferential Eddy Current Array Sensor

    Directory of Open Access Journals (Sweden)

    Huayu Zhang

    2017-07-01

    Full Text Available To efficiently inspect surface defects on steel ball bearings, a new method based on a circumferential eddy current array (CECA sensor was proposed here. The best probe configuration, in terms of the coil quality factor (Q-factor, magnetic field intensity, and induced eddy current density on the surface of a sample steel ball, was determined using 3-, 4-, 5-, and 6-coil probes, for analysis and comparison. The optimal lift-off from the measured steel ball, the number of probe coils, and the frequency of excitation current suitable for steel ball inspection were obtained. Using the resulting CECA sensor to inspect 46,126 steel balls showed a miss rate of ~0.02%. The sensor was inspected for surface defects as small as 0.05 mm in width and 0.1 mm in depth.

  1. Quality control of commercial bovine lactoferrin.

    Science.gov (United States)

    Wakabayashi, Hiroyuki; Yamauchi, Koji; Abe, Fumiaki

    2018-06-01

    Herein we review commercial bovine lactoferrin quality issues by describing an example of industrial production, the current status of global quality standardization, and quality-activity concerns for further discussion. Morinaga Milk Industry has been industrially producing bovine lactoferrin in Milei GmbH, Germany, since 1989. We delineate its production and quality as an example of safe and high-quality manufacturing. Currently, global standardization in the quality of bovine lactoferrin is progressing through Novel Food and GRAS in the EU and USA, respectively. Novel Food was applied or notified to seven lactoferrin manufacturers and GRAS was notified to three manufacturers, two of which are for infant use and one is for adult use, by the end of 2017. The specifications of these regulations are relatively high, including more than 95% lactoferrin purity in protein, which means that such companies can supply relatively high-grade lactoferrin. There appear to be several concerns regarding lactoferrin quality affecting activities, including contamination of lipopolysaccharide (LPS) and angiogenin, purity, and degradation of lactoferrin sample. Although LPS is immunologically toxic when invading the body, it is distributed normally in foods and the gut. However, an industrial lactoferrin sample may contain LPS at a maximum LPS/lactoferrin molecule ratio = 1/1724, which means 99.9% of the lactoferrin molecule is LPS-free. It is difficult to speculate that LPS contained in a lactoferrin sample affects its activities. Finally in order to achieve good and reproducible results, we make proposals to researchers a use of high-grade lactoferrin, careful storage, and indication the manufacturers' names and specifications in the paper.

  2. Current voltage characteristics of composite superconductors with high contact resistance

    International Nuclear Information System (INIS)

    Akhmetov, A.A.; Baev, V.P.

    1984-01-01

    An experimental study has been made of current-voltage characteristics of composite superconductors with contact resistance between superconducting filaments and normal metal with high electrical conductivity. It is shown that stable resistive states exist in such conductors over a wide range of currents. The presence of resistive states is interpreted in terms of the resistive domain concept. The minimum and maximum currents of resistive states are found to be dependent on the electrical resistance of normal metal and magnetic field. (author)

  3. Examination of Operation Quality for High-frequent Railway Operation

    DEFF Research Database (Denmark)

    Landex, Alex; Kaas, Anders H.

    2009-01-01

    take the first train in their direction. The article examines four different approaches to examine operation quality for high-frequent operation that are based on the experiences of the passengers. These approaches are the service frequency of the operation, travel time extension, a combination......The examination of operation quality for high-frequent operation requires other approaches than the typical evaluation of punctuality (trains on time) and reliability (operated trains). This is because passengers in high-frequent railway systems do not necessarily notice train delays as they just...... of the service frequency and travel time approaches, and passenger delays. The service frequency and travel time approaches are simple measurements with low complexity and complement each other. Therefore, the article recommends combining the service frequency and travel time approaches to get a more accurate...

  4. Prospects for Off-axis Current Drive via High Field Side Lower Hybrid Current Drive in DIII-D

    Science.gov (United States)

    Wukitch, S. J.; Shiraiwa, S.; Wallace, G. M.; Bonoli, P. T.; Holcomb, C.; Park, J. M.; Pinsker, R. I.

    2017-10-01

    An outstanding challenge for an economical, steady state tokamak is efficient off-axis current drive scalable to reactors. Previous studies have focused on high field side (HFS) launch of lower hybrid waves for current drive (LHCD) in double null configurations in reactor grade plasmas. The goal of this work is to find a HFS LHCD scenario for DIII-D that balances coupling, power penetration and damping. The higher magnetic field on the HFS improves wave accessibility, which allows for lower n||waves to be launched. These waves penetrate farther into the plasma core before damping at higher Te yielding a higher current drive efficiency. Utilizing advanced ray tracing and Fokker Planck simulation tools (GENRAY+CQL3D), wave penetration, absorption and drive current profiles in high performance DIII-D H-Mode plasmas were investigated. We found LH scenarios with single pass absorption, excellent wave penetration to r/a 0.6-0.8, FWHM r/a=0.2 and driven current up to 0.37 MA/MW coupled. These simulations indicate that HFS LHCD has potential to achieve efficient off-axis current drive in DIII-D and the latest results will be presented. Work supported by U.S. Dept. of Energy, Office of Science, Office of Fusion Energy Sciences, using User Facility DIII-D, under Award No. DE-FC02-04ER54698 and Contract No. DE-FC02-01ER54648 under Scientific Discovery through Advanced Computing Initiative.

  5. LTS and HTS high current conductor development for DEMO

    International Nuclear Information System (INIS)

    Bruzzone, Pierluigi; Sedlak, Kamil; Uglietti, Davide; Bykovsky, Nikolay; Muzzi, Luigi; De Marzi, Gainluca; Celentano, Giuseppe; Della Corte, Antonio; Turtù, Simonetta; Seri, Massimo

    2015-01-01

    Highlights: • Design and R&D for DEMO TF conductors. • Wind&react vs. react&wind options for Nb_3Sn high grade TF conductors. • Progress in the manufacture of short length Nb_3Sn proptotypes. • Design and prototype manufacture for high current HTS cabled conductors. - Abstract: The large size of the magnets for DEMO calls for very large operating current in the forced flow conductor. A plain extrapolation from the superconductors in use for ITER is not adequate to fulfill the technical and cost requirements. The proposed DEMO TF magnets is a graded winding using both Nb_3Sn and NbTi conductors, with operating current of 82 kA @ 13.6 T peak field. Two Nb_3Sn prototypes are being built in 2014 reflecting the two approaches suggested by CRPP (react&wind method) and ENEA (wind&react method). The Nb_3Sn strand (overall 200 kg) has been procured at technical specification similar to ITER. Both the Nb_3Sn strand and the high RRR, Cr plated copper wire (400 kg) have been delivered. The cabling trials are carried out at TRATOS Cavi using equipment relevant for long length production. The completion of the manufacture of the two 20 m long prototypes is expected in the end of 2014 and their test is planned in 2015 at CRPP. In the scope of a long term technology development, high current HTS conductors are built at CRPP and ENEA. A DEMO-class prototype conductor is developed and assembled at CRPP: it is a flat cable composed of 20 twisted stacks of coated conductor tape soldered into copper shells. The 10 kA conductor developed at ENEA consists of stacks of coated conductor tape inserted into a slotted and twisted Al core, with a central cooling channel. Samples have been manufactured in industrial environment and the scalability of the process to long production lengths has been proven.

  6. Generation and transportation of low-energy, high-current electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Ozur, G E; Proskurovskij, D I; Nazarov, D S [Russian Academy of Sciences, Tomsk (Russian Federation). Institute of High Current Electronics

    1997-12-31

    Experimental data on the production of low-energy, high-current electron beams in a plasma-filled diode are presented. The highest beam energy density achieved is about 40 J/cm{sup 2}, which makes it possible to treat materials in the mode of intense evaporation of the surface layer. It was shown that the use of a hollow cathode improves the beam homogeneity. The feasibility was demonstrated of the production of low-energy high-current electron beams in a gun with plasma anode based on the use of a reflective discharge. (author). 6 figs., 6 refs.

  7. A Survey of the Current Situation of Clinical Biobanks in China.

    Science.gov (United States)

    Li, Haiyan; Ni, Mingyu; Wang, Peng; Wang, Xiaomin

    2017-06-01

    The development of biomedical research urgently needs the support of a large number of high-quality clinical biospecimens. Therefore, human biobanks at different levels have been established successively in China and other countries at a significantly increasing pace in recent years. To better understand the general current state of clinical biobanks in China, we surveyed 42 clinical biobanks based in hospitals and collected information involving their management systems, sharing mechanisms, quality control systems, and informational management systems using closed questionnaire methods. Based on our current information, there has not been such a large-scale survey in China. An understanding of the status and challenges current clinical biobanks face will provide valuable insights for the construction and sustainable development of higher quality clinical biobanks.

  8. Embedding Quality Culture in Higher Education in Ghana: Quality Control and Assessment in Emerging Private Universities

    Science.gov (United States)

    Ntim, Stephen

    2014-01-01

    High quality provision has been one of the key aims of the current reforms in higher educational institutions across the globe since the beginning of the century and the millennium. Consequently this has led to the increasing demand for quality assurance (QA). This report identifies those institutional processes and structures that support the…

  9. Endorectal high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Devic, S.; Vuong, T.; Evans, M.; Podgorsak, E.

    2008-01-01

    We describe our quality assurance method for preoperative high dose rate (HDR) brachytherapy of endorectal tumours. Reproduction of the treatment planning dose distribution on a daily basis is crucial for treatment success. Due to the cylindrical symmetry, two types of adjustments are necessary: applicator rotation and dose distribution shift along the applicator axis. (author)

  10. A High-Sensitivity Current Sensor Utilizing CrNi Wire and Microfiber Coils

    Directory of Open Access Journals (Sweden)

    Xiaodong Xie

    2014-05-01

    Full Text Available We obtain an extremely high current sensitivity by wrapping a section of microfiber on a thin-diameter chromium-nickel wire. Our detected current sensitivity is as high as 220.65 nm/A2 for a structure length of only 35 μm. Such sensitivity is two orders of magnitude higher than the counterparts reported in the literature. Analysis shows that a higher resistivity or/and a thinner diameter of the metal wire may produce higher sensitivity. The effects of varying the structure parameters on sensitivity are discussed. The presented structure has potential for low-current sensing or highly electrically-tunable filtering applications.

  11. United States high-level radioactive waste management program: Current status and plans

    International Nuclear Information System (INIS)

    Williams, J.

    1992-01-01

    The inventory of spent fuel in storage at reactor sites in the United States is approximately 20,000 metric tons heavy metal (MTHM). It is increasing at a rate of 1700 to 2100 MTHM per year. According to current projections, by the time the last license for the current generation of nuclear reactors expires, there will be an estimated total of 84,000 MTHm. No commercial reprocessing capacity exists or is planned in the US. Therefore, the continued storage of spent fuel is required. The majority of spent fuel remains in the spent fuel pools of the utilities that generated it. Three utilities are presently supplementing pool capacity with on-site dry storage technologies, and four others are planning dry storage. Commercial utilities are responsible for managing their spent fuel until the Federal waste management system, now under development, accepts spent fuel for storage and disposal. Federal legislation charges the Office of Civilian Radioactive Waste Management (OCRWM) within the US Department of Energy (DOE) with responsibility for developing a system to permanently dispose of spent fuel and high level radioactive waste in a manner that protects the health and safety of the public and the quality of the environment. We are developing a waste management system consisting for three components: a mined geologic repository, with a projected start date of 2010; a monitored retrievable storage facility (MRS), scheduled to begin waste acceptance in 1998; and a transportation system to support MRS and repository operations. This paper discusses the background and framework for the program, as well as the current status and plans for management of spent nuclear fuel at commercial utilities; the OCRWM's development of a permanent geologic repository, an MRS, and a transportation system; the OCRWM's safety approach; the OCRWM's program management initiatives; and the OCRWM's external relations activities

  12. Low-leakage, high-current power crowbar transformer

    International Nuclear Information System (INIS)

    Buck, R.T.; Galbraith, J.D.; Nunnally, W.C.

    1979-01-01

    The design, fabrication, and testing of two sizes of power crowbar transformers for the ZT-40 Toroidal Z-Pinch experiment at the Los Alamos Scientific Laboratory are described. Low-leakage transformers in series with the poloidal and the toroidal field coils are used to sustain magnetic field currents initially produced by 50-kV capacitor banks. The transformer primaries are driven by cost-effective, ignitron-switched, 10-kV high-density capacitor banks. The transformer secondaries, in series with the field coils, provide from 1,000 to 1,500 V to cancel the resistive voltage drop in the coil circuits. Prototype transformers, with a total leakage inductance measured in the secondary of 5 nH, have been tested with peak secondary currents in excess of 600 kA resulting from a 10-kV primary charge voltage. The test procedures and results and the mechanical construction details are presented

  13. High current proton linear accelerators and nuclear power

    International Nuclear Information System (INIS)

    Tunnicliffe, P.R.; Chidley, B.G.; Fraser, J.S.

    1976-01-01

    This paper outlines a possible role that high-current proton linear accelerators might play as ''electrical breeders'' in the forthcoming nuclear-power economy. A high-power beam of intermediate energy protons delivered to an actinide-element target surrounded by a blanket of fertile material may produce fissile material at a competitive cost. Criteria for technical performance and, in a Canadian context, for costs are given and the major problem areas outlined not only for the accelerator and its associated rf power source but also for the target assembly. (author)

  14. Current status of high-T{sub c} wire

    Energy Technology Data Exchange (ETDEWEB)

    Vase, Per [Nordic Superconductor Technologies A/S, Priorparken 685, DK 2605 Broendby (Denmark); Fluekiger, Rene [Departement de Physique de la Matiere Condensee, Universite de Geneve (Switzerland); Leghissa, Martino [Siemens AG, Corporate Technology, Erlangen (Germany); Glowacki, Bartek [Department of Material Science and Metallurgy, University of Cambridge, Cambridge CB2 3QZ (United Kingdom)

    2000-07-01

    This paper is the result of the work of a SCENET (The European Network for Superconductivity) material working group's efforts on giving values for present and future expected performance of high-temperature superconducting (HTS) wires and tapes. The purpose of the work is to give input to the design of HTS applications like power cables, motors, current leads, magnets, transformers and generators. The current status performance values are supposed to be used in the design of today's prototypes and the future values for the design of fully commercial HTS applications of the future. We focus on what is expected to be the relevant parameters for HTS application design. The most successful technique by far for making HTS tapes has been on the (Bi, Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub x} (Bi-2223) material by the powder-in-tube (PIT) technique and this paper therefore focuses on giving the current status and expected future performance for Bi-2223 tapes. (author)

  15. Effects of Birkeland current limitation on high-latitude convection patterns

    International Nuclear Information System (INIS)

    Marklund, G.T.; Raadu, M.A.; Lindqvist, P.-A.

    1984-12-01

    It is shown how the high-latitude convection pattern may be mo- dified by substorm-enhanced polarization electric fields. These are generated whenever the flow of those Birkeland currents which are associated with ionospheric conductivity gradients is limited. Such Birkeland currents are fed mainly by the enhanced Pedersen current in the evening and morning sectors of the auro- ral oval and by the enhanced Hall current around local midnight. As the current limitation increases, the ionospheric potential, represented here by a symmetric two-cell pattern, will rotate clockwise and deform, just as the associated Birkeland current distribution. The resulting patterns are shown to agree well with observations. A pronounced westward intrusion of the equi- potential contours occurs in the auroral oval, and may be asso- ciated with the Westward Travelling Surge. This feature does not however require any assumed longitudinal conductivity gradi- ents. Rather it falls out naturally when the limitation of the enhanced Pedersen current is taken into account. (Author)

  16. The reliability-quality relationship for quality systems and quality risk management.

    Science.gov (United States)

    Claycamp, H Gregg; Rahaman, Faiad; Urban, Jason M

    2012-01-01

    Engineering reliability typically refers to the probability that a system, or any of its components, will perform a required function for a stated period of time and under specified operating conditions. As such, reliability is inextricably linked with time-dependent quality concepts, such as maintaining a state of control and predicting the chances of losses from failures for quality risk management. Two popular current good manufacturing practice (cGMP) and quality risk management tools, failure mode and effects analysis (FMEA) and root cause analysis (RCA) are examples of engineering reliability evaluations that link reliability with quality and risk. Current concepts in pharmaceutical quality and quality management systems call for more predictive systems for maintaining quality; yet, the current pharmaceutical manufacturing literature and guidelines are curiously silent on engineering quality. This commentary discusses the meaning of engineering reliability while linking the concept to quality systems and quality risk management. The essay also discusses the difference between engineering reliability and statistical (assay) reliability. The assurance of quality in a pharmaceutical product is no longer measured only "after the fact" of manufacturing. Rather, concepts of quality systems and quality risk management call for designing quality assurance into all stages of the pharmaceutical product life cycle. Interestingly, most assays for quality are essentially static and inform product quality over the life cycle only by being repeated over time. Engineering process reliability is the fundamental concept that is meant to anticipate quality failures over the life cycle of the product. Reliability is a well-developed theory and practice for other types of manufactured products and manufacturing processes. Thus, it is well known to be an appropriate index of manufactured product quality. This essay discusses the meaning of reliability and its linkages with quality

  17. Electron emission from nano-structured carbon composite materials and fabrication of high-quality electron emitters by using plasma technology

    International Nuclear Information System (INIS)

    Hiraki, H.; Hiraki, A.; Jiang, N.; Wang, H. X.

    2006-01-01

    Many trials have been done to fabricate high-quality electron-emitters from nano-composite carbon materials (such as nano-diamond, carbon nano tubes and others) by means of a variety of plasma chemical-vapor-deposition (CVD) techniques. Based upon the mechanism of electron emission, we have proposed several strategic guide lines for the fabrication of good emitters. Then, following these lines, several types of emitters were tried. One of the emitters has shown a worldclass, top ranking for fabricating very bright lamps: namely, a low turn-on voltage (0.5 ∼ 1 V/μm to induce 10 μA/cm 2 emission current) to emit a 1 mA/cm 2 current at 3 V/μm and 100 mA/cm 2 current at a slightly higher applied voltage. The bright lamps are Mercury-free fluorescence lamps to exhibit brightness of ∼10 5 cd/m 2 with high efficiency of ∼100 lm/w.

  18. R and D status of high-current accelerators at IFP

    International Nuclear Information System (INIS)

    Deng, J. J.; Shi, J. S.; Xie, W. P.

    2011-01-01

    High-current accelerators have many important applications in Z-pinches, high-power microwaves, and free electron lasers, imploding liners and radiography and so on. Research activities on Z-pinches, imploding liners, radiography at the Institute of Fluid Physics (IFP) are introduced. Several main high-current accelerators developed and being developed at IFP are described, such as the Linear Induction Accelerator X-Ray Facility Upgrade (LIAXFU, 12 MeV, 2.5 kA, 90 ns), the Dragon-I linear induction accelerator (20 MeV, 2.5 kA, 60 ns), and the Primary Test Stand for Z-pinch (PTS, 10 MA, 120 ns). The design of Dragon-II linear induction accelerator (20 MeV, 2.5 kA, 3 x 60 ns) to be built will be presented briefly.

  19. Superconducting fault current limiter using high-resistive YBCO tapes

    Energy Technology Data Exchange (ETDEWEB)

    Yazawa, T. [Power and Industrial System R and D Center, Toshiba Corporation, 2-4 Suehiro, Tsurumi, Yokohama 230-0045 (Japan)], E-mail: takashi.yazawa@toshiba.co.jp; Koyanagi, K.; Takahashi, M.; Ono, M.; Toba, K.; Takigami, H.; Urata, M. [Power and Industrial System R and D Center, Toshiba Corporation, 2-4 Suehiro, Tsurumi, Yokohama 230-0045 (Japan); Iijima, Y.; Saito, T. [Fujikura Ltd., 1-5-1 Kiba, Koto, Tokyo 135-0042 (Japan); Ameniya, N. [Yokohama National University, 79-1 Tokiwadai, Hodogaya, Yokohama 240-8501 (Japan); Shiohara, Y. [Superconductivity Research Laboratory, ISTEC, 1-10-13 Shinonome, Koto, Tokyo 135-0062 (Japan)

    2008-09-15

    One of the programs in the Ministry of Economy and Trade and Industry (METI) project regarding R and D on YBCO conductor is to evaluate the applicability of the developed conductor toward several applications. This paper focuses on a fault current limiter (FCL) as one of the expected power applications. YBCO tape conductors with ion beam assisted deposition (IBAD) substrate are used in this work. In order to obtain high resistance of the conductor, which is preferable to an FCL, the thickness of the protecting layer made of silver was decreased as possible. Then high-resistive metal stabilizing layer is attached on the silver layer to improve stability. Obtaining the relevant current limiting performance on short sample experiments, model coils were developed to aim the 6.6 kV-class FCL. Short circuit experiments were implemented with a short circuit generator. The coil successfully restricted the short circuit current over 17 kA to about 700 A by the applied voltage of 3.8 kV, which is nominal phase-to-ground voltage. The experimental results show good agreement with computer analyses and show promising toward the application.

  20. Using Principal Component and Tidal Analysis as a Quality Metric for Detecting Systematic Heading Uncertainty in Long-Term Acoustic Doppler Current Profiler Data

    Science.gov (United States)

    Morley, M. G.; Mihaly, S. F.; Dewey, R. K.; Jeffries, M. A.

    2015-12-01

    Ocean Networks Canada (ONC) operates the NEPTUNE and VENUS cabled ocean observatories to collect data on physical, chemical, biological, and geological ocean conditions over multi-year time periods. Researchers can download real-time and historical data from a large variety of instruments to study complex earth and ocean processes from their home laboratories. Ensuring that the users are receiving the most accurate data is a high priority at ONC, requiring quality assurance and quality control (QAQC) procedures to be developed for all data types. While some data types have relatively straightforward QAQC tests, such as scalar data range limits that are based on expected observed values or measurement limits of the instrument, for other data types the QAQC tests are more comprehensive. Long time series of ocean currents from Acoustic Doppler Current Profilers (ADCP), stitched together from multiple deployments over many years is one such data type where systematic data biases are more difficult to identify and correct. Data specialists at ONC are working to quantify systematic compass heading uncertainty in long-term ADCP records at each of the major study sites using the internal compass, remotely operated vehicle bearings, and more analytical tools such as principal component analysis (PCA) to estimate the optimal instrument alignments. In addition to using PCA, some work has been done to estimate the main components of the current at each site using tidal harmonic analysis. This paper describes the key challenges and presents preliminary PCA and tidal analysis approaches used by ONC to improve long-term observatory current measurements.

  1. Current measurement in high-performance frequency converters; Strommessung in Hochleistungsumrichtern

    Energy Technology Data Exchange (ETDEWEB)

    Marien, Jan; Hetzler, Ullrich [Isabellenhuette Heusler GmbH und Co. KG, Dillenburg (Germany); Hornung, Hans-Georg; Zwinger, Stefan [Sensor-Technik Wiedemann GmbH, Kaufbeuren (Germany)

    2011-04-15

    The load cycles (raising, lowering, accelerating, braking) of cranes, lift trucks and other off-road vehicles are ideally suited for the efficient deployment of hybrid or full electrical drive technology. Current measurement is a key technology for advancing electrification. Sensor Technik Wiedemann places by her frequency converters on a shunt-based current measurement module from Isabellenhuette Heusler which permits highly accurate measurements. (orig.)

  2. Observed currents at Bombay High during a winter

    Digital Repository Service at National Institute of Oceanography (India)

    Fernandes, A.A; Chandramohan, P.; Nayak, B.U.

    Ten day records of Aanderaa current meters (24 Dec 1981 to 2 Jan. 1982) at four depths, viz. 30, 45, 60 and 75 m at Bombay High (19˚24.5'N, 71˚2.5'E) off the west coast of India, in a water depth of 80 m have been subjected to spectral, cross...

  3. Critical current density and wire fabrication of high-TC superconductors

    International Nuclear Information System (INIS)

    Schlabach, T.D.; Jin, S.; Sherwood, R.C.; Tiefel, T.H.

    1989-01-01

    In this paper, some of the recent investigations of wire fabrication techniques and critical current behavior in high T c superconductors will be reviewed. In spite of the tremendous interest and research effort, the progress toward major applications of the bulk high-temperature superconductors has been impeded by, among other thins, the low critical currents and their severe deterioration in weak magnetic fields. Significant advances, however, have been made in understanding the causes of the problem as well as in improving the current-carrying capacity through proper microstructural control such as the melt-textured-growth in Y-Ba-Cu-O. The low density of effective flux-pinning sites in bulk Y-Ba-Cu-O limits J c at 77K in high magnetic fields to about 10 4 A/cm 2 even in the absence of weak links. Magnetization measurements on Bi-Sr-Ca-Cu-O and Tl-Ba-Ca-Cu-O at 77K by various researchers indicate even weaker flux pinning capabilities in these materials than in Y-Ba-Cu-O. The challenge in the future is to obtain suitable flux-pinning defects by choosing the right processing and chemistry changes

  4. High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Musumeci, P.; Moody, J. T.; Scoby, C. M.; Gutierrez, M. S. [Department of Physics and Astronomy, UCLA, Los Angeles, California 90095 (United States); Bender, H. A.; Wilcox, N. S. [National Security Technologies, LLC, Los Alamos Operations, Los Alamos, New Mexico 87544 (United States)

    2010-01-15

    Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

  5. High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector.

    Science.gov (United States)

    Musumeci, P; Moody, J T; Scoby, C M; Gutierrez, M S; Bender, H A; Wilcox, N S

    2010-01-01

    Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

  6. High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector

    International Nuclear Information System (INIS)

    Musumeci, P.; Moody, J. T.; Scoby, C. M.; Gutierrez, M. S.; Bender, H. A.; Wilcox, N. S.

    2010-01-01

    Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

  7. Recent results with a high-current, heavy-ion source system

    International Nuclear Information System (INIS)

    Keller, R.; Spaedtke, P.; Emig, H.

    1986-01-01

    In the last conference of this series, an improved high-current ion source for gases, CORDIS was presented. This source has been further developed to allow the processing of substances which are not volatile at room temperature. One of these modifications, HORDIS, incorporates an oven whereas the third version works at rather moderate temperatures and can be fed through a slightly heated external bottle. With this source system, high-current ion beams in the 100 mA range can be produced for a considerable part of the periodic table. Operation parameters and experiences with the sources are discussed, and the most recent results for all versions are given. (author)

  8. Effect of Abrikosov vortices on Josephson junction currents in high temperature superconductors

    International Nuclear Information System (INIS)

    Mitchell, E.; Mueller, K.-H.

    2000-01-01

    Full text: The current-carrying capacity of high temperature superconductors (HTS) is limited by the weak links which form between individual grains. We investigate the role of Abrikosov vortices (AV) and inhomogeneities at the intergrain boundary by examining the high magnetic field characteristics of HTS thin film grain boundary junctions. We model the effects of junction inhomogeneity, AV's and vortex pinning by solving the inhomogeneous London equation. The calculations show that both inhomogeneities and the presence of AV's improve the current-carrying capacity across grain boundaries at high magnetic fields. Our experimental measurements of the irreversibility of the junction critical current density J c (H a ) find good agreement with the model

  9. When high-volume PCI operators in high-volume hospitals move to lower volume hospitals-Do they still maintain high volume and quality of outcomes?

    Science.gov (United States)

    Lu, Tsung-Hsueh; Li, Sheng-Tun; Liang, Fu-Wen; Lee, Jo-Chi; Yin, Wei-Hsian

    2017-10-31

    The aim of this quasi-experimental study was to examine whether high-volume percutaneous coronary intervention (PCI) operators still maintain high volume and quality of outcomes when they moved to lower volume hospitals. Systematic reviews have indicated that high-volume PCI operators and hospitals have higher quality outcomes. However, little is known on whether high PCI volume and high quality outcomes are mainly due to operator characteristics (i.e., skill and experience) and is portable across organizations or whether it is due to hospital characteristics (i.e., equipment, team, and management system) and is less portable. We used Taiwan National Health Insurance claims data 2000-2012 to identify 98 high-volume PCI operators, 10 of whom moved from one hospital to another during the study period. We compared the PCI volume, risk-adjusted mortality ratio, and major adverse cardiovascular event (MACE) ratio before and after moving. Of the 10 high-volume operators who moved, 6 moved from high- to moderate- or low-volume hospitals, with median annual PCI volumes (interquartile range) of 130 (117-165) in prior hospitals and 54 (46-84) in subsequent hospitals (the hospital the operator moved to), and the remaining 4 moved from high to high-volume hospitals, with median annual PCI volumes (interquartile range) of 151 (133-162) in prior hospitals and 193 (178-239) in subsequent hospitals. No significant differences were observed in the risk-adjusted mortality ratios and MACE ratios between high-volume operators and matched controls before and after moving. High-volume operators cannot maintain high volume when they moved from high to moderate or low-volume hospitals; however, the quality of care is maintained. High PCI volume and high-quality outcomes are less portable and more hospital bound. © 2017 Wiley Periodicals, Inc.

  10. The Fast Tracker Real Time Processor: high quality real-time tracking at ATLAS

    CERN Document Server

    Stabile, A; The ATLAS collaboration

    2011-01-01

    As the LHC luminosity is ramped up to the design level of 1x1034 cm−2 s−1 and beyond, the high rates, multiplicities, and energies of particles seen by the detectors will pose a unique challenge. Only a tiny fraction of the produced collisions can be stored on tape and immense real-time data reduction is needed. An effective trigger system must maintain high trigger efficiencies for the most important physics and at the same time suppress the enormous QCD backgrounds. This requires massive computing power to minimize the online execution time of complex algorithms. A multi-level trigger is an effective solution for an otherwise impossible problem. The Fast Tracker (FTK)[1], [2] is a proposed upgrade to the current ATLAS trigger system that will operate at full Level-1 output rates and provide high quality tracks reconstructed over the entire detector by the start of processing in Level-2. FTK is a dedicated Super Computer based on a mixture of advanced technologies. The architecture broadly employs powerf...

  11. Does High-Quality Financial Reporting Mitigate the Negative Impact of Global Financial Crises on Firm Performance? Evidence from the United Kingdom

    Directory of Open Access Journals (Sweden)

    Zhiwei Lin

    2014-12-01

    Full Text Available Prior literature has claimed that accounting plays a negative role in a financial crisis. The current study sought to determine whether this effect is dependent on the quality of financial reporting. Specifically, this study examined the impact of the quality of financial reporting (as measured via earnings quality on liquidity (measured by the bid-ask spread in the equity market during the 2008–2009 global financial crisis in the United Kingdom. We found, as expected, that market liquidity was much lower during the crisis than prior to the crisis; however, firms with high-quality financial reporting suffered fewer negative effects as a result of the financial crisis. The results were robust after controlling for other influences, such as return volatility, loss making, market value of equity, and other potential endogeneity problems. In addition, adopting alternative models for earnings quality did not alter our inferences. Our results support the notion that high-quality accounting information can reduce information asymmetry and hence enhance investor confidence during a financial crisis. The results suggest that a stable financial reporting system is an important part of that overall economic fabric. Our findings will help build a framework on which an overall financial crisis risk-management strategy can be developed to avoid future crises.

  12. Guiding effect of bent macroscopic quartz tube for high current electron beam

    International Nuclear Information System (INIS)

    Zhang Mingwu; Chen Jing; Wu Yehong; Yang Bian; Wang Wei; Xue Yingli; Yu Deyang; Cai Xiaohong

    2012-01-01

    By using an incident electron beam with the high current and high energy, the guiding effect of the bent macroscopic quartz tube for the electron beam has been investigated. The angular distributions of outgoing electrons depending on the current and energy of incident electrons were measured. The dependences of electron transmitted fraction on energy and current of incident electrons are also shown. As the incident electron energy increasing, the electron transmitted fraction increases, but it decreases while the incident electron current increasing. The results have been compared with the present data. This work presents, the process of guiding electrons is essentially different from that of guiding highly charged ions, the guiding electron beam was caused by both elastic and inelastic collisions between electrons and inner walls of quartz tube, rather than self-organized charging effect on the surface of inner wall of quartz tube. (authors)

  13. Characteristics of primary care practices associated with high quality of care.

    Science.gov (United States)

    Beaulieu, Marie-Dominique; Haggerty, Jeannie; Tousignant, Pierre; Barnsley, Janet; Hogg, William; Geneau, Robert; Hudon, Éveline; Duplain, Réjean; Denis, Jean-Louis; Bonin, Lucie; Del Grande, Claudio; Dragieva, Natalyia

    2013-09-03

    No primary practice care model has been shown to be superior in achieving high-quality primary care. We aimed to identify the organizational characteristics of primary care practices that provide high-quality primary care. We performed a cross-sectional observational study involving a stratified random sample of 37 primary care practices from 3 regions of Quebec. We recruited 1457 patients who had 1 of 2 chronic care conditions or 1 of 6 episodic care conditions. The main outcome was the overall technical quality score. We measured organizational characteristics by use of a validated questionnaire and the Team Climate Inventory. Statistical analyses were based on multilevel regression modelling. The following characteristics were strongly associated with overall technical quality of care score: physician remuneration method (27.0; 95% confidence interval [CI] 19.0-35.0), extent of sharing of administrative resources (7.6; 95% CI 0.8-14.4), presence of allied health professionals (15.3; 95% CI 5.4-25.2) and/or specialist physicians (19.6; 95% CI 8.3-30.9), the presence of mechanisms for maintaining or evaluating competence (7.7; 95% CI 3.0-12.4) and average organizational access to the practice (4.9; 95% CI 2.6-7.2). The number of physicians (1.2; 95% CI 0.6-1.8) and the average Team Climate Inventory score (1.3; 95% CI 0.1-2.5) were modestly associated with high-quality care. We identified a common set of organizational characteristics associated with high-quality primary care. Many of these characteristics are amenable to change through practice-level organizational changes.

  14. Quality beyond compliance.

    Science.gov (United States)

    Centanni, N; Monroe, M; White, L; Larson, R

    1999-01-01

    The service sector within the biopharmaceutical industry has experienced phenomenal growth over the past decade. In the highly regulated Good Laboratory Practices environment, the need for timely, high-quality service, accurate results, and on-time deliverables becomes paramount for the success and profitability of biopharmaceutical companies. The quality assurance process is a vital component of this drug product-development cycle and ensures compliance to the highest domestic and international regulatory standards. Quality-assurance professionals historically have held the role of independent auditors of the processes, who certify that results meet current standards of practice. Covance, a contract research organization that includes Good Laboratory Practices laboratories, reorganized and expanded the functional responsibilities of its quality assurance team in 1997. Auditors and quality assurance professionals have assumed roles beyond traditional compliance auditing and are forging new leadership and mentoring roles as process-improvement specialists. The results have been tangible, measurable benefits for clients and the Covance organization. This article provides an overview of this cultural change and the processes put in place to improve efficiency, productivity, and customer and employee satisfaction.

  15. Proton-irradiation technology for high-frequency high-current silicon welding diode manufacturing

    Science.gov (United States)

    Lagov, P. B.; Drenin, A. S.; Zinoviev, M. A.

    2017-05-01

    Different proton irradiation regimes were tested to provide more than 20 kHz-frequency, soft reverse recovery “snap-less” behavior, low forward voltage drop and leakage current for 50 mm diameter 7 kA/400 V welding diode Al/Si/Mo structure. Silicon diode with such parameters is very suitable for high frequency resistance welding machines of new generation for robotic welding.

  16. High-temperature current conduction through three kinds of Schottky diodes

    International Nuclear Information System (INIS)

    Fei, Li; Xiao-Ling, Zhang; Yi, Duan; Xue-Song, Xie; Chang-Zhi, Lü

    2009-01-01

    Fundamentals of the Schottky contacts and the high-temperature current conduction through three kinds of Schottky diodes are studied. N-Si Schottky diodes, GaN Schottky diodes and AlGaN/GaN Schottky diodes are investigated by I–V–T measurements ranging from 300 to 523 K. For these Schottky diodes, a rise in temperature is accompanied with an increase in barrier height and a reduction in ideality factor. Mechanisms are suggested, including thermionic emission, field emission, trap-assisted tunnelling and so on. The most remarkable finding in the present paper is that these three kinds of Schottky diodes are revealed to have different behaviours of high-temperature reverse currents. For the n-Si Schottky diode, a rise in temperature is accompanied by an increase in reverse current. The reverse current of the GaN Schottky diode decreases first and then increases with rising temperature. The AlGaN/GaN Schottky diode has a trend opposite to that of the GaN Schottky diode, and the dominant mechanisms are the effects of the piezoelectric polarization field and variation of two-dimensional electron gas charge density. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  17. Choice of initial operating parameters for high average current linear accelerators

    International Nuclear Information System (INIS)

    Batchelor, K.

    1976-01-01

    Recent emphasis on alternative energy sources together with the need for intense neutron sources for testing of materials for CTR has resulted in renewed interest in high current (approximately 100 mA) c.w. proton and deuteron linear accelerators. In desinging an accelerator for such high currents, it is evident that beam losses in the machine must be minimized, which implies well matched beams, and that adequate acceptance under severe space charge conditions must be met. An investigation is presented of the input parameters to an Alvarez type drift-tube accelerator resulting from such factors. The analysis indicates that an accelerator operating at a frequency of 50 MHz is capable of accepting deuteron currents of about 0.4 amperes and proton currents of about 1.2 amperes. These values depend critically on the assumed values of beam emittance and on the ability to properly ''match'' this to the linac acceptance

  18. Development of large high current density superconducting solenoid magnets for use in high energy physics experiments

    International Nuclear Information System (INIS)

    Green, M.A.

    1977-05-01

    The development of a unique type of large superconducting solenoid magnet, characterized by very high current density windings and a two-phase helium tubular cooling system is described. The development of the magnet's conceptual design and the construction of two test solenoids are described. The successful test of the superconducting coil and its tubular cooling refrigeration system is presented. The safety, environmental and economic impacts of the test program on future developments in high energy physics are shown. Large solid angle particle detectors for colliding beam physics will analyze both charged and neutral particles. In many cases, these detectors will require neutral particles, such as gamma rays, to pass through the magnet coil with minimum interaction. The magnet coils must be as thin as possible. The use of superconducting windings allows one to minimize radiation thickness, while at the same time maximizing charged particle momentum resolution and saving substantial quantities of electrical energy. The results of the experimental measurements show that large high current density solenoid magnets can be made to operate at high stored energies. The superconducting magnet development described has a positive safety and environmental impact. The use of large high current density thin superconducting solenoids has been proposed in two high energy physics experiments to be conducted at the Stanford Linear Accelerator Center and Cornell University as a result of the successful experiments described

  19. High Current Ionic Diode Using Homogeneously Charged Asymmetric Nanochannel Network Membrane.

    Science.gov (United States)

    Choi, Eunpyo; Wang, Cong; Chang, Gyu Tae; Park, Jungyul

    2016-04-13

    A high current ionic diode is achieved using an asymmetric nanochannel network membrane (NCNM) constructed by soft lithography and in situ self-assembly of nanoparticles with uniform surface charge. The asymmetric NCNM exhibits high rectified currents without losing a rectification ratio because of its ionic selectivity gradient and differentiated electrical conductance. Asymmetric ionic transport is analyzed with diode-like I-V curves and visualized via fluorescent dyes, which is closely correlated with ionic selectivity and ion distribution according to variation of NCNM geometries.

  20. Isolation of high quality RNA from pistachio (Pistacia vera L.) and other woody plants high in secondary metabolites.

    Science.gov (United States)

    Moazzam Jazi, Maryam; Rajaei, Saideh; Seyedi, Seyed Mahdi

    2015-10-01

    The quality and quantity of RNA are critical for successful downstream transcriptome-based studies such as microarrays and RNA sequencing (RNA-Seq). RNA isolation from woody plants, such as Pistacia vera, with very high amounts of polyphenols and polysaccharides is an enormous challenge. Here, we describe a highly efficient protocol that overcomes the limitations posed by poor quality and low yield of isolated RNA from pistachio and various recalcitrant woody plants. The key factors that resulted in a yield of 150 μg of high quality RNA per 200 mg of plant tissue include the elimination of phenol from the extraction buffer, raising the concentration of β-mercaptoethanol, long time incubation at 65 °C, and nucleic acid precipitation with optimized volume of NaCl and isopropyl alcohol. Also, the A260/A280 and A260/A230 of extracted RNA were about 1.9-2.1and 2.2-2.3, respectively, revealing the high purity. Since the isolated RNA passed highly stringent quality control standards for sensitive reactions, including RNA sequencing and real-time PCR, it can be considered as a reliable and cost-effective method for RNA extraction from woody plants.

  1. Quack: A quality assurance tool for high throughput sequence data.

    Science.gov (United States)

    Thrash, Adam; Arick, Mark; Peterson, Daniel G

    2018-05-01

    The quality of data generated by high-throughput DNA sequencing tools must be rapidly assessed in order to determine how useful the data may be in making biological discoveries; higher quality data leads to more confident results and conclusions. Due to the ever-increasing size of data sets and the importance of rapid quality assessment, tools that analyze sequencing data should quickly produce easily interpretable graphics. Quack addresses these issues by generating information-dense visualizations from FASTQ files at a speed far surpassing other publicly available quality assurance tools in a manner independent of sequencing technology. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  2. Lower hybrid current drive at ITER-relevant high plasma densities

    International Nuclear Information System (INIS)

    Cesario, R.; Amicucci, L.; Cardinali, A.; Castaldo, C.; Marinucci, M.; Panaccione, L.; Pericoli-Ridolfini, V.; Tuccillo, A. A.; Tudisco, O.; Calabro, G.

    2009-01-01

    Recent experiments indicated that a further non-inductive current, besides bootstrap, should be necessary for developing advanced scenario for ITER. The lower hybrid current drive (LHCD) should provide such tool, but its effectiveness was still not proved in operations with ITER-relevant density of the plasma column periphery. Progress of the LH deposition modelling is presented, performed considering the wave physics of the edge, and different ITER-relevant edge parameters. Operations with relatively high edge electron temperatures are expected to reduce the LH || spectral broadening and, consequently, enabling the LH power to propagate also in high density plasmas ( || is the wavenumber component aligned to the confinement magnetic field). New results of FTU experiments are presented, performed by following the aforementioned modeling: they indicate that, for the first time, the LHCD conditions are established by operating at ITER-relevant high edge densities.

  3. What happens in Josephson junctions at high critical current densities

    Science.gov (United States)

    Massarotti, D.; Stornaiuolo, D.; Lucignano, P.; Caruso, R.; Galletti, L.; Montemurro, D.; Jouault, B.; Campagnano, G.; Arani, H. F.; Longobardi, L.; Parlato, L.; Pepe, G. P.; Rotoli, G.; Tagliacozzo, A.; Lombardi, F.; Tafuri, F.

    2017-07-01

    The impressive advances in material science and nanotechnology are more and more promoting the use of exotic barriers and/or superconductors, thus paving the way to new families of Josephson junctions. Semiconducting, ferromagnetic, topological insulator and graphene barriers are leading to unconventional and anomalous aspects of the Josephson coupling, which might be useful to respond to some issues on key problems of solid state physics. However, the complexity of the layout and of the competing physical processes occurring in the junctions is posing novel questions on the interpretation of their phenomenology. We classify some significant behaviors of hybrid and unconventional junctions in terms of their first imprinting, i.e., current-voltage curves, and propose a phenomenological approach to describe some features of junctions characterized by relatively high critical current densities Jc. Accurate arguments on the distribution of switching currents will provide quantitative criteria to understand physical processes occurring in high-Jc junctions. These notions are universal and apply to all kinds of junctions.

  4. Acceleration of a high-current single bunch in a linear accelerator

    International Nuclear Information System (INIS)

    Takeda, Seishi

    1984-01-01

    Some problems associated with the feasibility of an electron-positron linear collider with colliding energy of about 1x1 TeV are discussed. The first problem is related to the generation of high-current single bunch. A quasi-relativistic electron beam from an electron gun is injected into one bucket of the accelerating fields, in opposition to the longitudinal defocusing due to the space-charge effect. For generating a high-current single bunch, the beam bunching by means of the velocity modulation with a subharmonic prebuncher (SHPB) is indispensable. Three existing second generation single bunch electron linear accelerators (SLC, ANL and ISLR-Osaka Univ.) are briefly described. The results of the simulation of subharmonic-bunching is also reported. The second problem is associated with the physics of accelerating high-current single bunch. The longitudinal and transverse wake fields generated by a bunch-cavity interaction and the energy spread of the single bunch are analyzed and discussed. (Aoki, K.)

  5. Metastatic breast cancer: do current treatments improve quality of life? A prospective study

    Directory of Open Access Journals (Sweden)

    Fernanda Amado

    Full Text Available CONTEXT AND OBJECTIVE: In metastatic breast cancer cases, the currently available therapeutic approaches provide minimal improvement in survival. As such, quality of life (QOL becomes one of the main objectives of treatment. It is not known whether current treatments derived from trials improve QOL. The aim was to evaluate changes in QOL among metastatic breast cancer patients receiving treatment derived from trials. DESIGN AND SETTING: Prospective observational QOL survey in a tertiary cancer center. METHODS: To evaluate the influence of current treatments on patients' QOL, the Medical Outcomes Study Short Form-36 (SF-36 and the Beck Depression Inventory (BDI were applied on three occasions: before starting treatment and at the 6th and 12th weeks, to consecutive metastatic breast cancer patients over a one-year period. RESULTS: We found an improvement in QOL in the sample evaluated (n = 40, expressed by changes in the overall SF-36 score (p = 0.002 and the BDI (p = 0.004. Taken individually, the SF-36 components Pain, Social Functioning and Mental Health also improved significantly. Patients with worse initial performance status and secondary symptoms displayed greater improvement than those with better initial performance status and asymptomatic disease (p < 0.001. Patients who received more than one type of therapy showed larger gains than those given only one type (p = 0.038. CONCLUSIONS: In our environment, current metastatic breast cancer treatments can improve QOL, especially among symptomatic patients and those with low performance status.

  6. Study of a Particle Based Films Cure Process by High-Frequency Eddy Current Spectroscopy

    Directory of Open Access Journals (Sweden)

    Iryna Patsora

    2016-12-01

    Full Text Available Particle-based films are today an important part of various designs and they are implemented in structures as conductive parts, i.e., conductive paste printing in the manufacture of Li-ion batteries, solar cells or resistive paste printing in IC. Recently, particle based films were also implemented in the 3D printing technique, and are particularly important for use in aircraft, wind power, and the automotive industry when incorporated onto the surface of composite structures for protection against damages caused by a lightning strike. A crucial issue for the lightning protection area is to realize films with high homogeneity of electrical resistance where an in-situ noninvasive method has to be elaborated for quality monitoring to avoid undesirable financial and time costs. In this work the drying process of particle based films was investigated by high-frequency eddy current (HFEC spectroscopy in order to work out an automated in-situ quality monitoring method with a focus on the electrical resistance of the films. Different types of particle based films deposited on dielectric and carbon fiber reinforced plastic substrates were investigated in the present study and results show that the HFEC method offers a good opportunity to monitor the overall drying process of particle based films. Based on that, an algorithm was developed, allowing prediction of the final electrical resistance of the particle based films throughout the drying process, and was successfully implemented in a prototype system based on the EddyCus® HFEC device platform presented in this work. This prototype is the first solution for a portable system allowing HFEC measurement on huge and uneven surfaces.

  7. High-current heavy-ion accelerator system and its application to material modification

    International Nuclear Information System (INIS)

    Kishimoto, Naoki; Takeda, Yoshihiko; Lee, C.G.; Umeda, Naoki; Okubo, Nariaki; Iwamoto, Eiji

    2001-01-01

    A high-current heavy-ion accelerator system has been developed to realize intense particle fluxes for material modification. The facility of a tandem accelerator attained 1 mA-class ion current both for negative low-energy ions and positive high-energy ions. The negative ion source of the key device is of the plasma-sputter type, equipped with mutli-cusp magnets and Cs supply. The intense negative ions are either directly used for material irradiation at 60 keV or further accelerated up to 6 MeV after charge transformation. Application of negative ions, which alleviates surface charging, enables us to conduct low-energy high-current irradiation on insulating substrates. Since positive ions above the MeV range are irrelevant for Coulomb repulsion, the facility as a whole meets the needs of high-current irradiation onto insulators over a wide energy range. Application of high flux ions provides technological merits not only for efficient implantation but also for essentially different material kinetics, which may become an important tool of material modification. Other advantages of the system are co-irradiation by intense laser and in-situ detection of kinetic processes. For examples of material modifications, we present nanoparticle fabrication in insulators, and synergistic phenomena by co-irradiation due to ions and photons. (author)

  8. [Quality of sleep and academic performance in high school students].

    Science.gov (United States)

    Bugueño, Maithe; Curihual, Carolina; Olivares, Paulina; Wallace, Josefa; López-AlegrÍa, Fanny; Rivera-López, Gonzalo; Oyanedel, Juan Carlos

    2017-09-01

    Sleeping and studying are the day-to-day activities of a teenager attending school. To determine the quality of sleep and its relationship to the academic performance among students attending morning and afternoon shifts in a public high school. Students of the first and second year of high school answered an interview about socio-demographic background, academic performance, student activities and subjective sleep quality; they were evaluated using the Pittsburgh Sleep Quality Index (PSQI). The interview was answered by 322 first year students aged 15 ± 5 years attending the morning shift and 364 second year students, aged 16 ± 0.5 years, attending the afternoon shift. The components: sleep latency, habitual sleep efficiency, sleep disturbance, drug use and daytime dysfunction were similar and classified as good in both school shifts. The components subjective sleep quality and duration of sleep had higher scores among students of the morning shift. The mean grades during the first semester of the students attending morning and afternoon shifts were 5.9 and 5.8, respectively (of a scale from 1 to 7). Among students of both shifts, the PSQI scale was associated inversely and significantly with academic performance. A bad sleep quality influences academic performance in these students.

  9. extraction of high quality dna from polysaccharides-secreting ...

    African Journals Online (AJOL)

    cistvr

    A DNA extraction method using CTAB was used for the isolation of genomic DNA from ten. Xanthomonas campestris pathovars, ten isolates of Xanthomonas albilineans and one isolate of. Pseudomonas rubrisubalbicans. High quality DNA was obtained that was ideal for molecular analy- ses. Extracellular polysaccharides ...

  10. High-Protein and High-Dietary Fiber Breakfasts Result in Equal Feelings of Fullness and Better Diet Quality in Low-Income Preschoolers Compared with Their Usual Breakfast.

    Science.gov (United States)

    Kranz, Sibylle; Brauchla, Mary; Campbell, Wayne W; Mattes, Rickard D; Schwichtenberg, Amy J

    2017-03-01

    Background: In the United States, 17% of children are currently obese. Increasing feelings of fullness may prevent excessive energy intake, lead to better diet quality, and promote long-term maintenance of healthy weight. Objective: The purpose of this study was to develop a fullness-rating tool (aim 1) and to determine whether a high-protein (HP), high-fiber (HF), and combined HP and HF (HPHF) breakfast increases preschoolers' feelings of fullness before (pre) and after (post) breakfast and pre-lunch, as well as their diet quality, as measured by using a composite diet quality assessment tool, the Revised Children's Diet Quality Index (aim 2). Methods: Children aged 4 and 5 y ( n = 41; 22 girls and 19 boys) from local Head Start centers participated in this randomized intervention trial. Sixteen percent of boys and 32% of girls were overweight or obese. After the baseline week, children rotated through four 1-wk periods of consuming ad libitum HP (19-20 g protein), HF (10-11 g fiber), HPHF (19-21 g protein, 10-12 g fiber), or usual (control) breakfasts. Food intake at breakfast was estimated daily, and for breakfast, lunch, and snack on day 3 of each study week Student's t tests and ANOVA were used to determine statistical differences. Results: Children's post-breakfast and pre-lunch fullness ratings were ≥1 point higher than those of pre-breakfast (aim 1). Although children consumed, on average, 65 kcal less energy during the intervention breakfasts ( P diet quality (12%) was calculated for the HP and HF breakfasts ( P diet quality. Serving HP or HF breakfasts may be valuable in improving diet quality without lowering feelings of satiation or satiety. This trial was registered at clinicaltrials.gov as NCT02122224. © 2017 American Society for Nutrition.

  11. Managing quality inside a high-technology project organization

    OpenAIRE

    Jokinen, T. (Tauno)

    2004-01-01

    Abstract This action research addresses the deployment of Total Quality Management (TQM) principles in a high-technology new product development organisation. During the period of study, the organisation grew fast. High-technology product development and hypergrowth provided a unique combination of extreme conditions for the study. The existing concepts of TQM are presented as an organised map enabling strategic analysis for an implementation plan. The history of TQM dates back to the ...

  12. Proton-irradiation technology for high-frequency high-current silicon welding diode manufacturing

    International Nuclear Information System (INIS)

    Lagov, P B; Drenin, A S; Zinoviev, M A

    2017-01-01

    Different proton irradiation regimes were tested to provide more than 20 kHz-frequency, soft reverse recovery “snap-less” behavior, low forward voltage drop and leakage current for 50 mm diameter 7 kA/400 V welding diode Al/Si/Mo structure. Silicon diode with such parameters is very suitable for high frequency resistance welding machines of new generation for robotic welding. (paper)

  13. A battery-powered high-current power supply for superconductors

    CERN Document Server

    Wake, M; Suda, K

    2002-01-01

    Since superconductors do not require voltages, a high-current power supply could run with low power if the voltage is sufficiently reduced. Even a battery-powered power supply could give as much as 2,000A for a superconductor. To demonstrate this hypothesis, a battery-powered 2,000A power supply was constructed. It uses an IGBT chopper and Schottky diode together with a specially arranged transformer to produce a high current with low voltage. Testing of 2,000A operation was performed for about 1.5 hr using 10 car batteries. Charging time for this operation was 8 hr. Ramping control was smooth and caused no trouble. Although the IGBT frequency ripple of 16.6 kHz was easily removed using a passive filter, spike noise remained in the output voltage. This ripple did not cause any trouble in operating a pancake-type inductive superconducting load. (author)

  14. High quality transportation fuels from renewable feedstock

    Energy Technology Data Exchange (ETDEWEB)

    Lindfors, Lars Peter

    2010-09-15

    Hydrotreating of vegetable oils is novel process for producing high quality renewable diesel. Hydrotreated vegetable oils (HVO) are paraffinic hydrocarbons. They are free of aromatics, have high cetane numbers and reduce emissions. HVO can be used as component or as such. HVO processes can also be modified to produce jet fuel. GHG savings by HVO use are significant compared to fossil fuels. HVO is already in commercial production. Neste Oil is producing its NExBTL diesel in two plants. Production of renewable fuels will be limited by availability of sustainable feedstock. Therefore R and D efforts are made to expand feedstock base further.

  15. High-resolution wavefront control of high-power laser systems

    International Nuclear Information System (INIS)

    Brase, J.; Brown, C.; Carrano, C.; Kartz, M.; Olivier, S.; Pennington, D.; Silva, D.

    1999-01-01

    Nearly every new large-scale laser system application at LLNL has requirements for beam control which exceed the current level of available technology. For applications such as inertial confinement fusion, laser isotope separation, laser machining, and laser the ability to transport significant power to a target while maintaining good beam quality is critical. There are many ways that laser wavefront quality can be degraded. Thermal effects due to the interaction of high-power laser or pump light with the internal optical components or with the ambient gas are common causes of wavefront degradation. For many years, adaptive optics based on thing deformable glass mirrors with piezoelectric or electrostrictive actuators have be used to remove the low-order wavefront errors from high-power laser systems. These adaptive optics systems have successfully improved laser beam quality, but have also generally revealed additional high-spatial-frequency errors, both because the low-order errors have been reduced and because deformable mirrors have often introduced some high-spatial-frequency components due to manufacturing errors. Many current and emerging laser applications fall into the high-resolution category where there is an increased need for the correction of high spatial frequency aberrations which requires correctors with thousands of degrees of freedom. The largest Deformable Mirrors currently available have less than one thousand degrees of freedom at a cost of approximately $1M. A deformable mirror capable of meeting these high spatial resolution requirements would be cost prohibitive. Therefore a new approach using a different wavefront control technology is needed. One new wavefront control approach is the use of liquid-crystal (LC) spatial light modulator (SLM) technology for the controlling the phase of linearly polarized light. Current LC SLM technology provides high-spatial-resolution wavefront control, with hundreds of thousands of degrees of freedom, more

  16. High-Current Gain Two-Dimensional MoS 2 -Base Hot-Electron Transistors

    KAUST Repository

    Torres, Carlos M.

    2015-12-09

    The vertical transport of nonequilibrium charge carriers through semiconductor heterostructures has led to milestones in electronics with the development of the hot-electron transistor. Recently, significant advances have been made with atomically sharp heterostructures implementing various two-dimensional materials. Although graphene-base hot-electron transistors show great promise for electronic switching at high frequencies, they are limited by their low current gain. Here we show that, by choosing MoS2 and HfO2 for the filter barrier interface and using a noncrystalline semiconductor such as ITO for the collector, we can achieve an unprecedentedly high-current gain (α ∼ 0.95) in our hot-electron transistors operating at room temperature. Furthermore, the current gain can be tuned over 2 orders of magnitude with the collector-base voltage albeit this feature currently presents a drawback in the transistor performance metrics such as poor output resistance and poor intrinsic voltage gain. We anticipate our transistors will pave the way toward the realization of novel flexible 2D material-based high-density, low-energy, and high-frequency hot-carrier electronic applications. © 2015 American Chemical Society.

  17. High-Current Gain Two-Dimensional MoS 2 -Base Hot-Electron Transistors

    KAUST Repository

    Torres, Carlos M.; Lan, Yann Wen; Zeng, Caifu; Chen, Jyun Hong; Kou, Xufeng; Navabi, Aryan; Tang, Jianshi; Montazeri, Mohammad; Adleman, James R.; Lerner, Mitchell B.; Zhong, Yuan Liang; Li, Lain-Jong; Chen, Chii Dong; Wang, Kang L.

    2015-01-01

    The vertical transport of nonequilibrium charge carriers through semiconductor heterostructures has led to milestones in electronics with the development of the hot-electron transistor. Recently, significant advances have been made with atomically sharp heterostructures implementing various two-dimensional materials. Although graphene-base hot-electron transistors show great promise for electronic switching at high frequencies, they are limited by their low current gain. Here we show that, by choosing MoS2 and HfO2 for the filter barrier interface and using a noncrystalline semiconductor such as ITO for the collector, we can achieve an unprecedentedly high-current gain (α ∼ 0.95) in our hot-electron transistors operating at room temperature. Furthermore, the current gain can be tuned over 2 orders of magnitude with the collector-base voltage albeit this feature currently presents a drawback in the transistor performance metrics such as poor output resistance and poor intrinsic voltage gain. We anticipate our transistors will pave the way toward the realization of novel flexible 2D material-based high-density, low-energy, and high-frequency hot-carrier electronic applications. © 2015 American Chemical Society.

  18. Evaluation of Quality Assessment Protocols for High Throughput Genome Resequencing Data.

    Science.gov (United States)

    Chiara, Matteo; Pavesi, Giulio

    2017-01-01

    Large-scale initiatives aiming to recover the complete sequence of thousands of human genomes are currently being undertaken worldwide, concurring to the generation of a comprehensive catalog of human genetic variation. The ultimate and most ambitious goal of human population scale genomics is the characterization of the so-called human "variome," through the identification of causal mutations or haplotypes. Several research institutions worldwide currently use genotyping assays based on Next-Generation Sequencing (NGS) for diagnostics and clinical screenings, and the widespread application of such technologies promises major revolutions in medical science. Bioinformatic analysis of human resequencing data is one of the main factors limiting the effectiveness and general applicability of NGS for clinical studies. The requirement for multiple tools, to be combined in dedicated protocols in order to accommodate different types of data (gene panels, exomes, or whole genomes) and the high variability of the data makes difficult the establishment of a ultimate strategy of general use. While there already exist several studies comparing sensitivity and accuracy of bioinformatic pipelines for the identification of single nucleotide variants from resequencing data, little is known about the impact of quality assessment and reads pre-processing strategies. In this work we discuss major strengths and limitations of the various genome resequencing protocols are currently used in molecular diagnostics and for the discovery of novel disease-causing mutations. By taking advantage of publicly available data we devise and suggest a series of best practices for the pre-processing of the data that consistently improve the outcome of genotyping with minimal impacts on computational costs.

  19. Electrodynamic wear of rails in high current density rail gun discharges

    International Nuclear Information System (INIS)

    Edwards, W.T.; Caldwell, S.G.

    1984-01-01

    Significant advances in high current, high speed power sources, has in recent years allowed rail guns to produce very high velocity (> 10 km/sec) macroscopic particles (> 1/10 grams). A continuing problem is the structural integrity of the components under these loadings and in particular, the rail wear due to the high current density plasma contacts. In this investigation a small bore rail gun (6x5 mm) was used with a 10.6 kjoule capacitor energy source to examine the modes of rail damage. The rails were constructed of 110 copper base material. These rails were used in an uncoated condition and also with plasma sprayed coatings of W and W/WC. The resulting surface wear was characterized by standard metallurgical techniques and analyzed for the various coatings

  20. High current table-top setup for femtosecond gas electron diffraction

    Directory of Open Access Journals (Sweden)

    Omid Zandi

    2017-07-01

    Full Text Available We have constructed an experimental setup for gas phase electron diffraction with femtosecond resolution and a high average beam current. While gas electron diffraction has been successful at determining molecular structures, it has been a challenge to reach femtosecond resolution while maintaining sufficient beam current to retrieve structures with high spatial resolution. The main challenges are the Coulomb force that leads to broadening of the electron pulses and the temporal blurring that results from the velocity mismatch between the laser and electron pulses as they traverse the sample. We present here a device that uses pulse compression to overcome the Coulomb broadening and deliver femtosecond electron pulses on a gas target. The velocity mismatch can be compensated using laser pulses with a tilted intensity front to excite the sample. The temporal resolution of the setup was determined with a streak camera to be better than 400 fs for pulses with up to half a million electrons and a kinetic energy of 90 keV. The high charge per pulse, combined with a repetition rate of 5 kHz, results in an average beam current that is between one and two orders of magnitude higher than previously demonstrated.

  1. Improving high quality, equitable maternal health services in Malawi ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Improving high quality, equitable maternal health services in Malawi (IMCHA) ... In response, the Ministry of Health implemented a Standards-Based Management and Recognition for Reproductive Health initiative to improve ... Total funding.

  2. Growth and characterization of high current density, high-speed InAs/AlSb resonant tunneling diodes

    Science.gov (United States)

    Soderstrom, J. R.; Brown, E. R.; Parker, C. D.; Mahoney, L. J.; Yao, J. Y.

    1991-01-01

    InAs/AlSb double-barrier resonant tunneling diodes with peak current densities up to 370,000 A/sq cm and high peak-to-valley current ratios of 3.2 at room temperature have been fabricated. The peak current density is well-explained by a stationary-state transport model with the two-band envelope function approximation. The valley current density predicted by this model is less than the experimental value by a factor that is typical of the discrepancy found in other double-barrier structures. It is concluded that threading dislocations are largely inactive in the resonant tunneling process.

  3. High throughput electrospinning of high-quality nanofibers via an aluminum disk spinneret

    Science.gov (United States)

    Zheng, Guokuo

    In this work, a simple and efficient needleless high throughput electrospinning process using an aluminum disk spinneret with 24 holes is described. Electrospun mats produced by this setup consisted of fine fibers (nano-sized) of the highest quality while the productivity (yield) was many times that obtained from conventional single-needle electrospinning. The goal was to produce scaled-up amounts of the same or better quality nanofibers under variable concentration, voltage, and the working distance than those produced with the single needle lab setting. The fiber mats produced were either polymer or ceramic (such as molybdenum trioxide nanofibers). Through experimentation the optimum process conditions were defined to be: 24 kilovolt, a distance to collector of 15cm. More diluted solutions resulted in smaller diameter fibers. Comparing the morphologies of the nanofibers of MoO3 produced by both the traditional and the high throughput set up it was found that they were very similar. Moreover, the nanofibers production rate is nearly 10 times than that of traditional needle electrospinning. Thus, the high throughput process has the potential to become an industrial nanomanufacturing process and the materials processed by it may be used as filtration devices, in tissue engineering, and as sensors.

  4. Observations of propagating double layers in a high current discharge

    International Nuclear Information System (INIS)

    Lindberg, L.

    1988-01-01

    Observations of current disruptions and strong electric fields along the magnetic field in a high-density (2 x 10 19 m - 3 , highly-ionized, moving, and expanding plasma column are reported. The electric field is interpreted in terms of propagating, strong electric double layers (3-5kV). An initial plasma column is formed in an axial magnetic field (0.1T) by means of a conical theta-pinch plasma gun. When an axial current (max 5kA, 3-5 kV) is drawn through the column spontaneous disruptions and double-layer formation occur within a few microseconds. Floating, secondary emitting Langmuir probes are used. They often indicate very high positive potential peaks (1-2 kV above the anode potential during a few μs) in the plasma on the positive side of the double layer. Short, intense bursts of HF radiation are detected at the disruptions

  5. Metal-organic chemical vapor deposition of high quality, high indium composition N-polar InGaN layers for tunnel devices

    Science.gov (United States)

    Lund, Cory; Romanczyk, Brian; Catalano, Massimo; Wang, Qingxiao; Li, Wenjun; DiGiovanni, Domenic; Kim, Moon J.; Fay, Patrick; Nakamura, Shuji; DenBaars, Steven P.; Mishra, Umesh K.; Keller, Stacia

    2017-05-01

    In this study, the growth of high quality N-polar InGaN films by metalorganic chemical vapor deposition is presented with a focus on growth process optimization for high indium compositions and the structural and tunneling properties of such films. Uniform InGaN/GaN multiple quantum well stacks with indium compositions up to 0.46 were grown with local compositional analysis performed by energy-dispersive X-ray spectroscopy within a scanning transmission electron microscope. Bright room-temperature photoluminescence up to 600 nm was observed for films with indium compositions up to 0.35. To study the tunneling behavior of the InGaN layers, N-polar GaN/In0.35Ga0.65N/GaN tunnel diodes were fabricated which reached a maximum current density of 1.7 kA/cm2 at 5 V reverse bias. Temperature-dependent measurements are presented and confirm tunneling behavior under reverse bias.

  6. Coupling of high-quality-factor optical resonators

    International Nuclear Information System (INIS)

    Salzenstein, Patrice; Henriet, Rémi; Coillet, Aurélien; Chembo, Yanne K; Mortier, Michel; Sérier-Brault, Hélène; Rasoloniaina, Alphonse; Dumeige, Yannick; Féron, Patrice

    2013-01-01

    We improve theoretically and experimentally the problem of the coupling between a high Q-factor resonator and its external coupler. We have observed oscillations of ringing induced by the sweeping of the excitation frequency of an active microsphere. Thanks to this approach, the quality factor of an optical resonator was measured and we obtained Q = 5.8 × 10 8 . (paper)

  7. High-picture quality industrial CT scanner

    International Nuclear Information System (INIS)

    Shoji, Takao; Nishide, Akihiko; Fujii, Masashi.

    1989-01-01

    Industrial X-ray-CT-scanners, which provide cross-sectional images of a tested sample without destroying it, are attracting attention as a new nondestructive inspection device. In 1982, Toshiba commenced the development of industrial CT scanners, and introduced the 'TOSCANER' -3000 and-4000 series. Now, the state of the art 'TOSCANER'-20000 series of CT systems has been developed incorporating the latest computer tomography and image processing technology, such as the T9506 image processor. One of the advantages of this system is its applicability to a wide range of X-ray energy . The 'TOSCANER'-20000 series can be utilized for inspecting castings and other materials with relatively low-transparency to X-rays, as well as ceramics, composite materials and other materials with high X-ray transparency. A further feature of the new system is its high-picture quality, with a high-spatial resolution resulting from a pixel size of 0.2x0.2(mm). (author)

  8. Computer-aided control of high-quality cast iron

    Directory of Open Access Journals (Sweden)

    S. Pietrowski

    2008-04-01

    Full Text Available The study discusses the possibility of control of the high-quality grey cast iron and ductile iron using the author’s genuine computer programs. The programs have been developed with the help of algorithms based on statistical relationships that are said to exist between the characteristic parameters of DTA curves and properties, like Rp0,2, Rm, A5 and HB. It has been proved that the spheroidisation and inoculation treatment of cast iron changes in an important way the characteristic parameters of DTA curves, thus enabling a control of these operations as regards their correctness and effectiveness, along with the related changes in microstructure and mechanical properties of cast iron. Moreover, some examples of statistical relationships existing between the typical properties of ductile iron and its control process were given for cases of the melts consistent and inconsistent with the adopted technology.A test stand for control of the high-quality cast iron and respective melts has been schematically depicted.

  9. Eddy-current inspection of high flux isotope reactor nuclear control rods

    International Nuclear Information System (INIS)

    Smith, J.H.; Chitwood, L.D.

    1981-07-01

    Inner control rods for the High Flux Isotope Reactor were nondestructively inspected for defects by eddy-current techniques. During these examinations aluminum cladding thickness and oxide thickness on the cladding were also measured. Special application techniques were required because of the high-radiation levels (approx. 10 5 R/h at 30 cm) present and the relatively large temperature gradients that occurred on the surface of the control rods. The techniques used to perform the eddy-current inspections and the methods used to reduce the associated data are described

  10. High ion charge states in a high-current, short-pulse, vacuum ARC ion sources

    International Nuclear Information System (INIS)

    Anders, A.; Brown, I.; MacGill, R.; Dickinson, M.

    1996-01-01

    Ions of the cathode material are formed at vacuum arc cathode spots and extracted by a grid system. The ion charge states (typically 1-4) depend on the cathode material and only little on the discharge current as long as the current is low. Here the authors report on experiments with short pulses (several μs) and high currents (several kA); this regime of operation is thus approaching a more vacuum spark-like regime. Mean ion charge states of up to 6.2 for tungsten and 3.7 for titanium have been measured, with the corresponding maximum charge states of up to 8+ and 6+, respectively. The results are discussed in terms of Saha calculations and freezing of the charge state distribution

  11. High ion charge states in a high-current, short-pulse, vacuum arc ion source

    International Nuclear Information System (INIS)

    Anders, A.; Brown, I.; MacGill, R.; Dickinson, M.

    1995-09-01

    Ions of the cathode material are formed at vacuum arc cathode spots and extracted by a grid system. The ion charge states (typically 1--4) depend on the cathode material and only little on the discharge current as long as the current is low. Here the authors report on experiments with short pulses (several micros) and high currents (several kA); this regime of operation is thus approaching a more vacuum spark-like regime. Mean ion charge states of up to 6.2 for tungsten and 3.7 for titanium have been measured, with the corresponding maximum charge states of up to 8+ and 6+, respectively. The results are discussed in terms of Saha calculations and freezing of the charge state distribution

  12. Effect of high hydrostatic pressure on overall quality parameters of watermelon juice.

    Science.gov (United States)

    Liu, Y; Zhao, X Y; Zou, L; Hu, X S

    2013-06-01

    High hydrostatic pressure as a kind of non-thermal processing might maintain the quality of thermo-sensitive watermelon juice. So, the effect of high hydrostatic pressure treatment on enzymes and quality of watermelon juice was investigated. After high hydrostatic pressure treatment, the activities of polyphenol oxidase, peroxidase, and pectin methylesterase of juice decreased significantly with the pressure (P  0.05). No significant difference was observed in lycopene and total phenolics after high hydrostatic pressure treatment when compared to the control (P > 0.05). Cloudiness and viscosity increased with pressure (P  0.05). a*- and b*-value both unchanged after high hydrostatic pressure treatment (P > 0.05) while L*-value increased but the values had no significant difference among treated juices. Browning degree after high hydrostatic pressure treatment decreased with increase in pressure and treatment time (P hydrostatic pressure had little effect on color of juice. The results of this study demonstrated the efficacy of high hydrostatic pressure in inactivating enzymes and maintaining the quality of watermelon juice.

  13. Current concept review: quality and process improvement in orthopedics

    Directory of Open Access Journals (Sweden)

    Pinney SJ

    2015-12-01

    Full Text Available Stephen J Pinney,1 Alexandra E Page,2 David S Jevsevar,3 Kevin J Bozic4 1Department of Orthopaedic Surgery, St Mary's Medical Center, San Francisco, CA, USA; 2Orthopaedic Surgery, AAOS Health Care Systems Committee, San Diego, CA, USA; 3Department of Orthopaedics, Geisel School of Medicine, Dartmouth University, Hanover, NH, USA; 4Department of Surgery and Perioperative Care, Dell Medical School at the University of Texas, Austin, TX, USAAbstract: Multiple health care stakeholders are increasingly scrutinizing musculoskeletal care to optimize quality and cost efficiency. This has led to greater emphasis on quality and process improvement. There is a robust set of business strategies that are increasingly being applied to health care delivery. These quality and process improvement tools (QPITs have specific applications to segments of, or the entire episode of, patient care. In the rapidly changing health care world, it will behoove all orthopedic surgeons to have an understanding of the manner in which care delivery processes can be evaluated and improved. Many of the commonly used QPITs, including checklist initiatives, standardized clinical care pathways, lean methodology, six sigma strategies, and total quality management, embrace basic principles of quality improvement. These principles include focusing on outcomes, optimizing communication among health care team members, increasing process standardization, and decreasing process variation. This review summarizes the common QPITs, including how and when they might be employed to improve care delivery. Keywords: clinical care pathway, musculoskeletal care, outcomes, quality management, six sigma, lean thinking

  14. Resonant tunneling with high peak to valley current ratio in SiO2/nc-Si/SiO2 multi-layers at room temperature

    International Nuclear Information System (INIS)

    Chen, D. Y.; Sun, Y.; He, Y. J.; Xu, L.; Xu, J.

    2014-01-01

    We have investigated carrier transport in SiO 2 /nc-Si/SiO 2 multi-layers by room temperature current-voltage measurements. Resonant tunneling signatures accompanied by current peaks are observed. Carrier transport in the multi-layers were analyzed by plots of ln(I/V 2 ) as a function of 1/V and ln(I) as a function of V 1/2 . Results suggest that besides films quality, nc-Si and barrier sub-layer thicknesses are important parameters that restrict carrier transport. When thicknesses are both small, direct tunneling dominates carrier transport, resonant tunneling occurs only at certain voltages and multi-resonant tunneling related current peaks can be observed but with peak to valley current ratio (PVCR) values smaller than 1.5. When barrier thickness is increased, trap-related and even high field related tunneling is excited, causing that multi-current peaks cannot be observed clearly, only one current peak with higher PVCR value of 7.7 can be observed. While if the thickness of nc-Si is large enough, quantum confinement is not so strong, a broad current peak with PVCR value as high as 60 can be measured, which may be due to small energy difference between the splitting energy levels in the quantum dots of nc-Si. Size distribution in a wide range may cause un-controllability of the peak voltages

  15. High quality ceramic coatings sprayed by high efficiency hypersonic plasma spraying gun

    International Nuclear Information System (INIS)

    Zhu Sheng; Xu Binshi; Yao JiuKun

    2005-01-01

    This paper introduced the structure of the high efficiency hypersonic plasma spraying gun and the effects of hypersonic plasma jet on the sprayed particles. The optimised spraying process parameters for several ceramic powders such as Al 2 O 3 , Cr 2 O 3 , ZrO 2 , Cr 3 C 2 and Co-WC were listed. The properties and microstructure of the sprayed ceramic coatings were investigated. Nano Al 2 O 3 -TiO 2 ceramic coating sprayed by using the high efficiency hypersonic plasma spraying was also studied. Compared with the conventional air plasma spraying, high efficiency hypersonic plasma spraying improves greatly the ceramic coatings quality but at low cost. (orig.)

  16. Isolation of high-quality total RNA from leaves of Myrciaria dubia "CAMU CAMU".

    Science.gov (United States)

    Gómez, Juan Carlos Castro; Reátegui, Alina Del Carmen Egoavil; Flores, Julián Torres; Saavedra, Roberson Ramírez; Ruiz, Marianela Cobos; Correa, Sixto Alfredo Imán

    2013-01-01

    Myrciaria dubia is a main source of vitamin C for people in the Amazon region. Molecular studies of M. dubia require high-quality total RNA from different tissues. So far, no protocols have been reported for total RNA isolation from leaves of this species. The objective of this research was to develop protocols for extracting high-quality total RNA from leaves of M. dubia. Total RNA was purified following two modified protocols developed for leaves of other species (by Zeng and Yang, and by Reid et al.) and one modified protocol developed for fruits of the studied species (by Silva). Quantity and quality of purified total RNA were assessed by spectrophotometric and electrophoretic analysis. Additionally, quality of total RNA was evaluated with reverse-transcription polymerase chain reaction (RT-PCR). With these three modified protocols we were able to isolate high-quality RNA (A260nm/A280nm >1.9 and A260nm/A230nm >2.0). Highest yield was produced with the Zeng and Yang modified protocol (384±46µg ARN/g fresh weight). Furthermore, electrophoretic analysis showed the integrity of isolated RNA and the absence of DNA. Another proof of the high quality of our purified RNA was the successful cDNA synthesis and amplification of a segment of the M. dubia actin 1 gene. We report three modified protocols for isolation total RNA from leaves of M. dubia. The modified protocols are easy, rapid, low in cost, and effective for high-quality and quantity total RNA isolation suitable for cDNA synthesis and polymerase chain reaction.

  17. Stationary high confinement plasmas with large bootstrap current fraction in JT-60U

    International Nuclear Information System (INIS)

    Sakamoto, Y.; Fujita, T.; Ide, S.; Isayama, A.; Takechi, M.; Suzuki, T.; Takenaga, H.; Oyama, N.; Kamada, Y.

    2005-01-01

    This paper reports the results of the progress in stationary discharges with a large bootstrap current fraction in JT-60U towards steady-state tokamak operation. In the weak shear plasma regime, high-β p ELMy H-mode discharges have been optimized under nearly full non-inductive current drive conditions by the large bootstrap current fraction (f BS ∼ 45%) and the beam driven current fraction (f BD ∼ 50%), which was sustained for 5.8 s in the stationary condition. This duration corresponds to ∼26τ E and ∼2.8τ R , which was limited by the pulse length of negative-ion-based neutral beams. The high confinement enhancement factor H 89 ∼ 2.2 (HH 98y2 ∼ 1.0) was obtained and the profiles of current and pressure reached the stationary condition. In the reversed shear plasma regime, a large bootstrap current fraction (f BS ∼ 75%) has been sustained for 7.4 s under nearly full non-inductive current drive conditions. This duration corresponds to ∼16τ E and ∼2.7τ R . The high confinement enhancement factor H 89 ∼ 3.0 (HH 98y2 ∼ 1.7) was also sustained, and the profiles of current and pressure reached the stationary condition. The large bootstrap current and the off-axis beam driven current sustained this reversed q profile. This duration was limited only by the duration of the neutral beam injection

  18. High-temperature performance of MoS{sub 2} thin-film transistors: Direct current and pulse current-voltage characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, C.; Samnakay, R.; Balandin, A. A., E-mail: balandin@ee.ucr.edu [Nano-Device Laboratory (NDL), Department of Electrical Engineering, Bourns College of Engineering, University of California—Riverside, Riverside, California 92521 (United States); Phonon Optimized Engineered Materials (POEM) Center, Materials Science and Engineering Program, University of California—Riverside, Riverside, California 92521 (United States); Rumyantsev, S. L. [Department of Electrical, Computer, and Systems Engineering, Center for Integrated Electronics, Rensselaer Polytechnic Institute, Troy, New York 12180 (United States); Ioffe Physical-Technical Institute, St. Petersburg 194021 (Russian Federation); Shur, M. S. [Department of Electrical, Computer, and Systems Engineering, Center for Integrated Electronics, Rensselaer Polytechnic Institute, Troy, New York 12180 (United States)

    2015-02-14

    We report on fabrication of MoS{sub 2} thin-film transistors (TFTs) and experimental investigations of their high-temperature current-voltage characteristics. The measurements show that MoS{sub 2} devices remain functional to temperatures of at least as high as 500 K. The temperature increase results in decreased threshold voltage and mobility. The comparison of the direct current (DC) and pulse measurements shows that the direct current sub-linear and super-linear output characteristics of MoS{sub 2} thin-films devices result from the Joule heating and the interplay of the threshold voltage and mobility temperature dependences. At temperatures above 450 K, a kink in the drain current occurs at zero gate voltage irrespective of the threshold voltage value. This intriguing phenomenon, referred to as a “memory step,” was attributed to the slow relaxation processes in thin films similar to those in graphene and electron glasses. The fabricated MoS{sub 2} thin-film transistors demonstrated stable operation after two months of aging. The obtained results suggest new applications for MoS{sub 2} thin-film transistors in extreme-temperature electronics and sensors.

  19. HIGH QUALITY FACADE SEGMENTATION BASED ON STRUCTURED RANDOM FOREST, REGION PROPOSAL NETWORK AND RECTANGULAR FITTING

    Directory of Open Access Journals (Sweden)

    K. Rahmani

    2018-05-01

    Full Text Available In this paper we present a pipeline for high quality semantic segmentation of building facades using Structured Random Forest (SRF, Region Proposal Network (RPN based on a Convolutional Neural Network (CNN as well as rectangular fitting optimization. Our main contribution is that we employ features created by the RPN as channels in the SRF.We empirically show that this is very effective especially for doors and windows. Our pipeline is evaluated on two datasets where we outperform current state-of-the-art methods. Additionally, we quantify the contribution of the RPN and the rectangular fitting optimization on the accuracy of the result.

  20. Negative Binomial charts for monitoring high-quality processes

    NARCIS (Netherlands)

    Albers, Willem/Wim

    Good control charts for high quality processes are often based on the number of successes between failures. Geometric charts are simplest in this respect, but slow in recognizing moderately increased failure rates p. Improvement can be achieved by waiting until r > 1 failures have occurred, i.e. by

  1. High quality mask storage in an advanced Logic-Fab

    Science.gov (United States)

    Jähnert, Carmen; Fritsche, Silvio

    2012-02-01

    High efficient mask logistics as well as safe and high quality mask storage are essential requirements within an advanced lithography area of a modern logic waferfab. Fast operational availability of the required masks at the exposure tool with excellent mask condition requires a safe mask handling, safeguarding of high mask quality over the whole mask usage time without any quality degradation and an intelligent mask logistics. One big challenge is the prevention of haze on high advanced phase shift masks used in a high volume production line for some thousands of 248nm or 193nm exposures. In 2008 Infineon Dresden qualified a customer specific developed semi-bare mask storage system from DMSDynamic Micro Systems in combination with a high advanced mask handling and an interconnected complex logistic system. This high-capacity mask storage system DMS M1900.22 for more than 3000 masks with fully automated mask and box handling as well as full-blown XCDA purge has been developed and adapted to the Infineon Lithotoollandscape using Nikon and SMIF reticle cases. Advanced features for ESD safety and mask security, mask tracking via RFID and interactions with the exposure tools were developed and implemented. The stocker is remote controlled by the iCADA-RSM system, ordering of the requested mask directly from the affected exposure tool allows fast access. This paper discusses the advantages and challenges for this approach as well as the practical experience gained during the implementation of the new system which improves the fab performance with respect to mask quality, security and throughput. Especially the realization of an extremely low and stable humidity level in addition with a well controlled air flow at each mask surface, preventing masks from haze degradation and particle contamination, turns out to be a notable technical achievement. The longterm stability of haze critical masks has been improved significantly. Relevant environmental parameters like

  2. IMPACT OF RESILIENCE, ICT SUPPORT AND QUALITY OF STUDENT'S LIFE ON QUALITY OF HIGH EDUCATION PROCESS

    Directory of Open Access Journals (Sweden)

    Zorica Lazic

    2016-12-01

    Full Text Available Answers to the questions of how and in what way the quality of life of students, resilience and ICT support affects the quality of high education we will get through this work where main objective is to define a network of processes and process management ensuring more quality and more innovative managing and service provision, therefore satisfying the needs of service users - in this case the students of the university. To collect the relevant data in the thematic analysis of this paper, the method of interviewing by questionnaires was applied. The sample survey was conducted among undergraduate students, teachers and staff of the Teacher Training Faculty in Uzice.

  3. The effects of high frequency current ripple on electric vehicle battery performance

    International Nuclear Information System (INIS)

    Uddin, Kotub; Moore, Andrew D.; Barai, Anup; Marco, James

    2016-01-01

    Highlights: • Experimental study into the impact of current ripple on li-ion battery degradation. • 15 cells exercised with 1200 cycles coupled AC–DC signals, at 5 frequencies. • Results highlight a greater spread of degradation for cells exposed to AC excitation. • Implications for BMS control, thermal management and system integration. - Abstract: The power electronic subsystems within electric vehicle (EV) powertrains are required to manage both the energy flows within the vehicle and the delivery of torque by the electrical machine. Such systems are known to generate undesired electrical noise on the high voltage bus. High frequency current oscillations, or ripple, if unhindered will enter the vehicle’s battery system. Real-world measurements of the current on the high voltage bus of a series hybrid electric vehicle (HEV) show that significant current perturbations ranging from 10 Hz to in excess of 10 kHz are present. Little is reported within the academic literature about the potential impact on battery system performance and the rate of degradation associated with exposing the battery to coupled direct current (DC) and alternating currents (AC). This paper documents an experimental investigation that studies the long-term impact of current ripple on battery performance degradation. Initial results highlight that both capacity fade and impedance rise progressively increase as the frequency of the superimposed AC current increases. A further conclusion is that the spread of degradation for cells cycled with a coupled AC–DC signal is considerably more than for cells exercised with a traditional DC waveform. The underlying causality for this degradation is not yet understood. However, this has important implications for the battery management system (BMS). Increased variations in cell capacity and impedance will cause differential current flows and heat generation within the battery pack that if not properly managed will further reduce battery life

  4. Generation and application of soft-X-ray by means of inverse compton scattering between high quality election beam and IR laser

    International Nuclear Information System (INIS)

    Washio, M.; Sakaue, K.; Hama, Y.; Kamiya, Y.; Moriyama, R.; Hezume, K.; Saito, T.; Kuroda, R.; Kashiwagi, S.; Ushida, K.; Hayano, H.; Urakawa, J.

    2006-01-01

    High quality beam generation project based on High-Tech Research Center Project, which has been approved by Ministry of Education, Culture, Sports, Science and Technology in 1999, has been conducted by advance research institute for science and engineering, Waseda University. In the project, laser photo-cathode RF-gun has been selected for the high quality electron beam source. RF cavities with low dark current, which were made by diamond turning technique, have been successfully manufactured. The low emittance electron beam was realized by choosing the modified laser injection technique. The obtained normalized emittance was about 3 mm·mrad at 100 pC of electron charge. The soft X-ray beam generation with the energy of 370 eV, which is in the energy region of so-called 'water window', by inverse Compton scattering has been performed by the collision between IR laser and the low emittance electron beams. (authors)

  5. Visualisation of the high-current e-beams on solid surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Solomonov, V I; Osipov, V V; Mikhajlov, S G; Lipchak, A I [Russian Academy of Sciences, Ural Division, Ekaterinburg (Russian Federation). Institute of Electrophysics

    1997-12-31

    Natural minerals such as spodumen, calcite, and Mn-doped apatite crystals may serve as suitable low-cost materials for visualization of high-current electron beams. High-intensity luminescence lasting several tens of minutes has been observed when irradiating natural specimen by electron beams with the current density of 10-1000 A/sq.cm, with energy of 100-300 keV, and pulse duration of 2-50 ns. The luminescent images of the beam cross-section provide information on the beam density profiles, while the images taken in the plane parallel to the beam axis make it possible to estimate the beam penetration depth and, therefore, the beam energy. The method is illustrated by examples of luminescent images taken from the experiment. (J.U.).

  6. Theory and application of high temperature superconducting eddy current probes for nondestructive evaluation

    Science.gov (United States)

    Claycomb, James Ronald

    1998-10-01

    Several High-T c Superconducting (HTS) eddy current probes have been developed for applications in electromagnetic nondestructive evaluation (NDE) of conducting materials. The probes utilize high-T c SUperconducting Quantum Interference Device (SQUID) magnetometers to detect the fields produced by the perturbation of induced eddy currents resulting from subsurface flaws. Localized HTS shields are incorporated to selectively screen out environmental electromagnetic interference and enable movement of the instrument in the Earth's magnetic field. High permeability magnetic shields are employed to focus flux into, and thereby increase the eddy current density in the metallic test samples. NDE test results are presented, in which machined flaws in aluminum alloy are detected by probes of different design. A novel current injection technique performing NDE of wires using SQUIDs is also discussed. The HTS and high permeability shields are designed based on analytical and numerical finite element method (FEM) calculations presented here. Superconducting and high permeability magnetic shields are modeled in uniform noise fields and in the presence of dipole fields characteristic of flaw signals. Several shield designs are characterized in terms of (1) their ability to screen out uniform background noise fields; (2) the resultant improvement in signal-to-noise ratio and (3) the extent to which dipole source fields are distorted. An analysis of eddy current induction is then presented for low frequency SQUID NDE. Analytical expressions are developed for the induced eddy currents and resulting magnetic fields produced by excitation sources above conducting plates of varying thickness. The expressions derived here are used to model the SQUID's response to material thinning. An analytical defect model is also developed, taking into account the attenuation of the defect field through the conducting material, as well as the current flow around the edges of the flaw. Time harmonic

  7. RIKEN 200 kV high current implanter for metal surface modification

    International Nuclear Information System (INIS)

    Iwaki, M.; Yoshida, K.; Sakudo, N.

    1985-01-01

    A high current, metal ion implanter was constructed in order to aid the formation of a new metastable surface alloy. This implanter, called a RIKEN 200 kV high current implanter, is a modified Lintott high current machine (Series III), which has the advantages of having its own microwave ion source and an extra target chamber. The microwave discharge ion source without a hot-filament has a comparatively long lifetime because the chloride ions and radicals in a plasma during discharge of metal chlorides might prevent metal to deposit on the inner walls of the discharge chamber by bombarding and chemically cleaning them. An extra target chamber for metal modification is able to control the surface composition by utilizing the sputtering effect of the ion beam during ion implantation. The use of this ion source and the extra target chamber is suggested to be suitable for the production of metallic ions and for the implantation into metals. The case study will be introduced for TI implantation into Fe. (orig.)

  8. Prefronto-Cerebellar Transcranial Direct Current Stimulation Improves Sleep Quality in Euthymic Bipolar Patients: A Brief Report

    Directory of Open Access Journals (Sweden)

    Amedeo Minichino

    2014-01-01

    Full Text Available Introduction. Sleep problems are common in bipolar disorder (BD and may persist during the euthymic phase of the disease. The aim of the study was to improve sleep quality of euthymic BD patients through the administration of prefronto-cerebellar transcranial direct current stimulation (tDCS. Methods. 25 euthymic outpatients with a diagnosis of BD Type I or II have been enrolled in the study. tDCS montage was as follows: cathode on the right cerebellar cortex and anode over the left dorsolateral prefrontal cortex (DLPFC; the intensity of stimulation was set at 2 mA and delivered for 20 min/die for 3 consecutive weeks. The Pittsburgh Sleep Quality Index (PSQI was used to assess sleep quality at baseline and after the tDCS treatment. Results. PSQI total score and all PSQI subdomains, with the exception of “sleep medication,” significantly improved after treatment. Discussion. This is the first study where a positive effect of tDCS on the quality of sleep in euthymic BD patients has been reported. As both prefrontal cortex and cerebellum may play a role in regulating sleep processes, concomitant cathodal (inhibitory stimulation of cerebellum and anodal (excitatory stimulation of DLPFC may have the potential to modulate prefrontal-thalamic-cerebellar circuits leading to improvements of sleep quality.

  9. Learning Disabilities and Achieving High-Quality Education Standards

    Science.gov (United States)

    Gartland, Debi; Strosnider, Roberta

    2017-01-01

    This is an official document of the National Joint Committee on Learning Disabilities (NJCLD), of which Council for Learning Disabilities is a long-standing, active member. With this position paper, NJCLD advocates for the implementation of high-quality education standards (HQES) for students with learning disabilities (LD) and outlines the…

  10. Modeling photo-desorption in high current storage rings

    International Nuclear Information System (INIS)

    Barletta, W.A.

    1991-01-01

    High luminosity flavor factories are characterized by high fluxes of synchrotron radiation that lead to thermal management difficulties. The associated photo-desorption from the vacuum chamber walls presents an additional design challenge, providing a vacuum system suitable for maintaining acceptable beam-gas lifetimes and low background levels of scattered radiation in the detector. Achieving acceptable operating pressures (1-10 nTorr) with practical pumping schemes requires the use of materials with low photodesorption efficiency operating in a radiation environment beyond that of existing storage rings. Extrapolating the existing photo-desorption data base to the design requirements of high luminosity colliders requires a physical model of the differential cleaning in the vacuum chamber. The authors present a simple phenomenological model of photodesorption that includes effects of dose dependence and diffuse photon reflection to compute the leveling of gas loads in beamlines of high current storage rings that typify heavy flavor factories. This model is also used to estimate chamber commissioning times

  11. CCD Astrophotography High-Quality Imaging from the Suburbs

    CERN Document Server

    Stuart, Adam

    2006-01-01

    This is a reference book for amateur astronomers who have become interested in CCD imaging. Those glorious astronomical images found in astronomy magazines might seem out of reach to newcomers to CCD imaging, but this is not the case. Great pictures are attainable with modest equipment. Adam Stuart’s many beautiful images, reproduced in this book, attest to the quality of – initially – a beginner’s efforts. Chilled-chip astronomical CCD-cameras and software are also wonderful tools for cutting through seemingly impenetrable light-pollution. CCD Astrophotography from the Suburbs describes one man’s successful approach to the problem of getting high-quality astronomical images under some of the most light-polluted conditions. Here is a complete and thoroughly tested program that will help every CCD-beginner to work towards digital imaging of the highest quality. It is equally useful to astronomers who have perfect observing conditions, as to those who have to observe from light-polluted city skies.

  12. Measurements of the reverse current of highly irradiated silicon sensors to determine the effective energy and current related damage rate

    Science.gov (United States)

    Wiehe, Moritz; Wonsak, S.; Kuehn, S.; Parzefall, U.; Casse, G.

    2018-01-01

    The reverse current of irradiated silicon sensors leads to self heating of the sensor and degrades the signal to noise ratio of a detector. Precise knowledge of the expected reverse current during detector operation is crucial for planning and running experiments in High Energy Physics. The dependence of the reverse current on sensor temperature and irradiation fluence is parametrized by the effective energy and the current related damage rate, respectively. In this study 18 n-in-p mini silicon strip sensors from companies Hamamatsu Photonics and Micron Semiconductor Ltd. were deployed. Measurements of the reverse current for different bias voltages were performed at temperatures of -32 ° C, -27 ° C and -23 ° C. The sensors were irradiated with reactor neutrons in Ljubljana to fluences ranging from 2 × 1014neq /cm2 to 2 × 1016neq /cm2. The measurements were performed directly after irradiation and after 10 and 30 days of room temperature annealing. The aim of the study presented in this paper is to investigate the reverse current of silicon sensors for high fluences of up to 2 × 1016neq /cm2 and compare the measurements to the parametrization models.

  13. Properties of high-spin boson interaction currents and elimination of power divergences

    International Nuclear Information System (INIS)

    Kulish, Yu.V.; Rybachuk, E.V.

    2001-01-01

    The problem of the elimination of the power divergences for the interactions of the high-spin bosons (J ≥ 1) is investigated. It is proved that in the consistent theory the high-spin boson interaction currents and the field tensors must obey similar requirements. Therefore the momentum dependencies of the propagators for all the bosons are the same. The partial differential equations derived for some components include the derivatives of order 2J for the currents. Therefore the current components for the spin-J boson must decrease with the momentum Kombi scalar p v Kombi scalar → ∞ at least as Kombi scalar p v Kombi scalar -2J

  14. On Leakage Current Measured at High Cell Voltages in Lithium-Ion Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Vadivel, Nicole R.; Ha, Seungbum; He, Meinan; Dees, Dennis; Trask, Steve; Polzin, Bryant; Gallagher, Kevin G.

    2017-01-01

    In this study, parasitic side reactions in lithium-ion batteries were examined experimentally using a potentiostatic hold at high cell voltage. The experimental leakage current measured during the potentiostatic hold was compared to the Tafel expression and showed poor agreement with the expected transfer coefficient values, indicating that a more complicated expression could be needed to accurately capture the physics of this side reaction. Here we show that cross-talk between the electrodes is the primary contribution to the observed leakage current after the relaxation of concentration gradients has ceased. This cross-talk was confirmed with experiments using a lithium-ion conducting glass ceramic (LICGC) separator, which has high conductance only for lithium cations. The cells with LICGC separators showed significantly less leakage current during the potentiostatic hold test compared to cells with standard microporous separators where cross-talk is present. In addition, direct-current pulse power tests show an impedance rise for cells held at high potentials and for cells held at high temperatures, which could be attributed to film formation from the parasitic side reaction. Based on the experimental findings, a phenomenological mechanism is proposed for the parasitic side reaction which accounts for cross-talk and mass transport of the decomposition products across the separator.

  15. Electrical and hydrodynamic characterization of a high current pulsed arc

    International Nuclear Information System (INIS)

    Sousa Martins, R; Chemartin, L; Zaepffel, C; Lalande, Ph; Soufiani, A

    2016-01-01

    High current pulsed arcs are of significant industrial interest and, aiming to reduce time and cost, there is progressively more and more need for computation tools that describe and predict the behaviour of these arcs. These simulation codes need inputs and validations by experimental databases, but accurate data is missing for this category of electric discharges. The principal lack of understanding is with respect to the transient phase of the current, which can reach thousands of amperes in a few microseconds. In this paper, we present the work realized on an experimental setup that simulates in the laboratory an arc column subjected to five levels of high pulsed current, ranging from 10 kA to 100 kA, with the last one corresponding to the standard lightning current waveform used in aircraft certification processes. This device was instrumented by high speed video cameras to assess the characteristic sizes of the arc channel and to characterize the shock wave generated by the arc expansion. The arc channel radius was measured over time during the axisymmetric phase and reached 3.2 cm. The position and velocity of the shock wave was determined during the first 140 μs. The background-oriented schlieren method was used to study the shock wave and a model for the light deflection inside the shock wave was developed. The mass density profile of the shock wave was estimated and showed good agreement with Rankine–Hugoniot relations at the wave front. Electrical measurements were also used to estimate the time-dependent resistance and conductivity of the arc for times lasting up to 50 μs. (paper)

  16. Electrical and hydrodynamic characterization of a high current pulsed arc

    Science.gov (United States)

    Sousa Martins, R.; Chemartin, L.; Zaepffel, C.; Lalande, Ph; Soufiani, A.

    2016-05-01

    High current pulsed arcs are of significant industrial interest and, aiming to reduce time and cost, there is progressively more and more need for computation tools that describe and predict the behaviour of these arcs. These simulation codes need inputs and validations by experimental databases, but accurate data is missing for this category of electric discharges. The principal lack of understanding is with respect to the transient phase of the current, which can reach thousands of amperes in a few microseconds. In this paper, we present the work realized on an experimental setup that simulates in the laboratory an arc column subjected to five levels of high pulsed current, ranging from 10 kA to 100 kA, with the last one corresponding to the standard lightning current waveform used in aircraft certification processes. This device was instrumented by high speed video cameras to assess the characteristic sizes of the arc channel and to characterize the shock wave generated by the arc expansion. The arc channel radius was measured over time during the axisymmetric phase and reached 3.2 cm. The position and velocity of the shock wave was determined during the first 140 μs. The background-oriented schlieren method was used to study the shock wave and a model for the light deflection inside the shock wave was developed. The mass density profile of the shock wave was estimated and showed good agreement with Rankine-Hugoniot relations at the wave front. Electrical measurements were also used to estimate the time-dependent resistance and conductivity of the arc for times lasting up to 50 μs.

  17. The influence of knowledge management implementation toward the quality of high schools

    Directory of Open Access Journals (Sweden)

    Hilda Ainissyifa

    2012-09-01

    Full Text Available The purpose of this study is to analyze the influence of knowledge management implementation toward the quality of high schools. This study was conducted among five high schools under an education foundation. The analysis models used in the study were correlation analysis and t-test. The respondents were used as the profession references are 86 teachers. The result of the study shows that knowledge management implementation has a positive and significant influence toward the quality of high schools.

  18. Boiling curve in high quality flow boiling

    International Nuclear Information System (INIS)

    Shiralkar, B.S.; Hein, R.A.; Yadigaroglu, G.

    1980-01-01

    The post dry-out heat transfer regime of the flow boiling curve was investigated experimentally for high pressure water at high qualities. The test section was a short round tube located downstream of a hot patch created by a temperature controlled segment of tubing. Results from the experiment showed that the distance from the dryout point has a significant effect on the downstream temperatures and there was no unique boiling curve. The heat transfer coefficients measured sufficiently downstream of the dryout point could be correlated using the Heineman correlation for superheated steam, indicating that the droplet deposition effects could be neglected in this region

  19. Application of parallel connected power-MOSFET elements to high current d.c. power supply

    International Nuclear Information System (INIS)

    Matsukawa, Tatsuya; Shioyama, Masanori; Shimada, Katsuhiro; Takaku, Taku; Neumeyer, Charles; Tsuji-Iio, Shunji; Shimada, Ryuichi

    2001-01-01

    The low aspect ratio spherical torus (ST), which has single turn toroidal field coil, requires the extremely high d.c. current like as 20 MA to energize the coil. Considering the ratings of such extremely high current and low voltage, power-MOSFET element is employed as the switching device for the a.c./d.c. converter of power supply. One of the advantages of power-MOSFET element is low on-state resistance, which is to meet the high current and low voltage operation. Recently, the capacity of power-MOSFET element has been increased and its on-state resistance has been decreased, so that the possibility of construction of high current and low voltage a.c./d.c. converter with parallel connected power-MOSFET elements has been growing. With the aim of developing the high current d.c. power supply using power-MOSFET, the basic characteristics of parallel operation with power-MOSFET elements are experimentally investigated. And, the synchronous rectifier type and the bi-directional self commutated type a.c./d.c. converters using parallel connected power-MOSFET elements are proposed

  20. Use of high current density superconducting coils in fusion devices

    International Nuclear Information System (INIS)

    Green, M.A.

    1979-11-01

    Superconducting magnets will play an important role in fusion research in years to come. The magnets which are currently proposed for fusion research use the concept of cryostability to insure stable operation of the superconducting coils. This paper proposes the use of adiabatically stable high current density superconducting coils in some types of fusion devices. The advantages of this approach are much lower system cold mass, enhanced cryogenic safety, increased access to the plasma and lower cost

  1. CBE growth of high-quality ZnO epitaxial layers

    Energy Technology Data Exchange (ETDEWEB)

    El-Shaer, A.; Bakin, A.; Mofor, A.C.; Kreye, M.; Waag, A. [Institute of Semiconductor Technology, Technical University Braunschweig, Hans-Sommer-Strasse 66, 38106 Braunschweig (Germany); Blaesing, J.; Krost, A. [Institute of Experimental Physics, Otto-von-Guericke-University Magdeburg (Germany); Stoimenos, J. [Physics Department, Aristotele University, Univ. Campus, 54006 Thessaloniki (Greece); Pecz, B. [Research Institute for Technical Physics and Materials Science, Hungarian Academy of Sciences, P.O. Box 49, 1525 Budapest (Hungary); Heuken, M. [Aixtron AG, Kackertstr. 15-17, 52072 Aachen (Germany)

    2006-03-15

    Further improvements on the recently reported novel approach to zinc oxide Chemical Beam Epitaxy (CBE) are presented. Hydrogen peroxide is employed as a very efficient novel oxidant. ZnO layers with a thickness from 100 nm to 600 nm were grown on c-sapphire using a MgO buffer. PL-mapping as well as conductivity mapping shows a good uniformity across the 2 inch ZnO-on-sapphire epiwafers. The measured surface roughness for the best layers is as low as 0.26 nm. HRXRD measurements of the obtained ZnO layers show excellent quality of the single crystalline ZnO. The FWHM of the HRXRD (0002) rocking curves measured for the 2 inch ZnO-on-sapphire wafers is as low as 27 arcsec with a very high lateral homogeneity across the whole wafer. Plane view HRTEM observations reveal the very good quality of the ZnO films. The results indicate that CBE is a suitable technique to fabricate ZnO of very high structural quality, which can eventually be used as an alternative to bulk ZnO substrates. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  2. Design of a Highly Stable, High-Conversion-Efficiency, Optical Parametric Chirped-Pulse Amplification System with Good Beam Quality

    International Nuclear Information System (INIS)

    Guardalben, M.J.; Keegan, J.; Waxer, L.J.; Bagnoud, V.; Begishev, I.A.; Puth, J.; Zuegel, J.D.

    2003-01-01

    OAK B204 An optical parametric chirped-pulse amplifier (OPCPA) design that provides 40% pump-to-signal conversion efficiency and over-500-mJ signal energy at 1054 nm for front-end injection into a Nd:glass amplifier chain is presented. This OPCPA system is currently being built as the prototype front end for the OMEGA EP (extended performance) laser system at the University of Rochester's Laboratory for Laser Energetics. Using a three-dimensional spatial and temporal numerical model, several design considerations necessary to achieve high conversion efficiency, good output stability, and good beam quality are discussed. The dependence of OPCPA output on the pump beam's spatiotemporal shape and the relative size of seed and pump beams is described. This includes the effects of pump intensity modulation and pump-signal walk-off. The trade-off among efficiency, stability, and low output beam intensity modulation is discussed

  3. High quality factor GaAs microcavity with buried bullseye defects

    DEFF Research Database (Denmark)

    Winkler, K.; Gregersen, Niels; Hayrynen, T.

    2018-01-01

    The development of high quality factor solid-state microcavities with low mode volumes has paved the way towards on-chip cavity quantum electrodynamics experiments and the development of high-performance nanophotonic devices. Here, we report on the implementation of a new kind of solid...

  4. Operating modes of high-Tc composite superconductors and thermal runaway conditions under current charging

    International Nuclear Information System (INIS)

    Romanovskii, V R; Watanabe, K

    2006-01-01

    The operating thermal and electric modes of a high-T c superconducting composite in partially and fully penetrated states induced by the charging current are investigated. They were studied under conditions in which the current charging rate, the volume fraction of the superconductor in a composite or the temperature of the cooling bath were changed. The transient behaviour of the voltage-current dependence, which is characteristic during stable and unstable increases in electric field inside the composite under a continuous current charging, is discussed. Simulations were done using zero- and one-dimensional steady and unsteady thermoelectric models with a power equation describing the virgin voltage-current characteristic of a superconductor. It is found that some thermoelectric trends underlie the shape of the voltage-current characteristic of the high-T c superconducting composite. These have to be considered during experiments in which the critical or quench currents are defined. First, in the initial stage of the fully penetrated regime (in the low voltage range), the electric field distribution does not have a uniform character. These states depend on the volume fraction of the superconductor and the current charging rate: the higher these quantities, the higher the heterogeneity of the electric field. Second, during the stable over-critical regime (in the high voltage range) occurring in complete penetration modes, the evolution of the electric field may depend on the relevant temperature increase of a composite according to the corresponding increase in its temperature-dependent heat capacity. Consequently, the shape of the voltage-current characteristic of a composite high-T c superconductor during continuous current charging, both before and after thermal runaway, has only a positive slope. Moreover, it is proved that the growth of the fully penetrated part of the voltage-current characteristic becomes less intensive when the current charging rate or the

  5. Low-cost high-quality crystalline germanium based flexible devices

    KAUST Repository

    Nassar, Joanna M.

    2014-06-16

    High performance flexible electronics promise innovative future technology for various interactive applications for the pursuit of low-cost, light-weight, and multi-functional devices. Thus, here we show a complementary metal oxide semiconductor (CMOS) compatible fabrication of flexible metal-oxide-semiconductor capacitors (MOSCAPs) with high-κ/metal gate stack, using a physical vapor deposition (PVD) cost-effective technique to obtain a high-quality Ge channel. We report outstanding bending radius ~1.25 mm and semi-transparency of 30%.

  6. Low-cost high-quality crystalline germanium based flexible devices

    KAUST Repository

    Nassar, Joanna M.; Hussain, Aftab M.; Rojas, Jhonathan Prieto; Hussain, Muhammad Mustafa

    2014-01-01

    High performance flexible electronics promise innovative future technology for various interactive applications for the pursuit of low-cost, light-weight, and multi-functional devices. Thus, here we show a complementary metal oxide semiconductor (CMOS) compatible fabrication of flexible metal-oxide-semiconductor capacitors (MOSCAPs) with high-κ/metal gate stack, using a physical vapor deposition (PVD) cost-effective technique to obtain a high-quality Ge channel. We report outstanding bending radius ~1.25 mm and semi-transparency of 30%.

  7. Pulsed high current ion beam processing equipment

    International Nuclear Information System (INIS)

    Korenev, S.A.; Perry, A.

    1995-01-01

    A pulsed high voltage ion source is considered for use in ion beam processing for the surface modification of materials, and deposition of conducting films on different substrates. The source consists of an Arkad'ev-Marx high voltage generator, a vacuum ion diode based on explosive ion emission, and a vacuum chamber as substrate holder. The ion diode allows conducting films to be deposited from metal or allow sources, with ion beam mixing, onto substrates held at a pre-selected temperature. The main variables can be set in the ranges: voltage 100-700 kV, pulse length 0.3 μs, beam current 1-200 A depending on the ion chosen. The applications of this technology are discussed in semiconductor, superconductor and metallizing applications as well as the direction of future development and cost of these devices for commercial application. 14 refs., 6 figs

  8. High-quality GaN epitaxially grown on Si substrate with serpentine channels

    Science.gov (United States)

    Wei, Tiantian; Zong, Hua; Jiang, Shengxiang; Yang, Yue; Liao, Hui; Xie, Yahong; Wang, Wenjie; Li, Junze; Tang, Jun; Hu, Xiaodong

    2018-06-01

    A novel serpentine-channeled mask was introduced to Si substrate for low-dislocation GaN epitaxial growth and the fully coalesced GaN film on the masked Si substrate was achieved for the first time. Compared with the epitaxial lateral overgrowth (ELOG) growth method, this innovative mask only requires one-step epitaxial growth of GaN which has only one high-dislocation region per mask opening. This new growth method can effectively reduce dislocation density, thus improving the quality of GaN significantly. High-quality GaN with low dislocation density ∼2.4 × 107 cm-2 was obtained, which accounted for about eighty percent of the GaN film in area. This innovative technique is promising for the growth of high-quality GaN templates and the subsequent fabrication of high-performance GaN-based devices like transistors, laser diodes (LDs), and light-emitting diodes (LEDs) on Si substrate.

  9. High current photoemission with 10 picosecond uv pulses

    International Nuclear Information System (INIS)

    Fischer, J.; Srinivasan-Rao, T.; Tsang, T.

    1990-06-01

    The quantum efficiency and the optical damage threshold of various metals were explored with 10 ps, 266 nm, UV laser pulses. Efficiencies for Cu, Y, and Sm were: 1.4, 5, and 7 x 10 -4 , with damage thresholds about 100, 10, and 30 mJ/cm 2 . This would permit over 1 μC/cm 2 or current densities exceeding 100 kA/cm 2 . High charge and current densities of up to 66 kA/cm 2 were obtained on 0.25 mm diam cathodes, and 21 kA/cm 2 on a 3 mm diam yttrium cathode. The maximum currents were limited by space charge and the dc field. The experiments with small area illumination indicate that the emitted electrons spread transversely due to Coulomb repulsion and their initial transverse velocity. This increases the effective area above the cathode, reduces the space charge effect and increases emission density on the cathode. The quantum efficiency can be increased substantially by enhancing the field on the surface by either a suitable electrode geometry or microstructures on it. 14 refs., 12 figs., 3 tabs

  10. Ultra fast shutter driven by pulsed high current

    International Nuclear Information System (INIS)

    Zeng Jiangtao; Sun Fengju; Qiu Aici; Yin Jiahui; Guo Jianming; Chen Yulan

    2005-01-01

    Radiation simulation utilizing plasma radiation sources (PRS) generates a large number of undesirable debris, which may damage the expensive diagnosing detectors. An ultra fast shutter (UFS) driven by pulsed high current can erect a physical barrier to the slowly moving debris after allowing the passage of X-ray photons. The UFS consists of a pair of thin metal foils twisting the parallel axes in a Nylon cassette, compressed with an outer magnetic field, generated from a fast capacitor bank, discharging into a single turn loop. A typical capacitor bank is of 7.5 μF charging voltages varying from 30 kV to 45 kV, with corresponding currents of approximately 90 kA to 140 kA and discharging current periods of approximately 13.1 μs. A shutter closing time as fast as 38 microseconds has been obtained with an aluminium foil thickness of 100 micrometers and a cross-sectional area of 15 mm by 20 mm. The design, construction and the expressions of the valve-closing time of the UFS are presented along with the measured results of valve-closing velocities. (authors)

  11. Improving data quality and supervision of antiretroviral therapy sites in Malawi: an application of Lot Quality Assurance Sampling

    Directory of Open Access Journals (Sweden)

    Hedt-Gauthier Bethany L

    2012-07-01

    Full Text Available Abstract Background High quality program data is critical for managing, monitoring, and evaluating national HIV treatment programs. By 2009, the Malawi Ministry of Health had initiated more than 270,000 patients on HIV treatment at 377 sites. Quarterly supervision of these antiretroviral therapy (ART sites ensures high quality care, but the time currently dedicated to exhaustive record review and data cleaning detracts from other critical components. The exhaustive record review is unlikely to be sustainable long term because of the resources required and increasing number of patients on ART. This study quantifies the current levels of data quality and evaluates Lot Quality Assurance Sampling (LQAS as a tool to prioritize sites with low data quality, thus lowering costs while maintaining sufficient quality for program monitoring and patient care. Methods In January 2010, a study team joined supervision teams at 19 sites purposely selected to reflect the variety of ART sites. During the exhaustive data review, the time allocated to data cleaning and data discrepancies were documented. The team then randomly sampled 76 records from each site, recording secondary outcomes and the time required for sampling. Results At the 19 sites, only 1.2% of records had discrepancies in patient outcomes and 0.4% in treatment regimen. However, data cleaning took 28.5 hours in total, suggesting that data cleaning for all 377 ART sites would require over 350 supervision-hours quarterly. The LQAS tool accurately identified the sites with the low data quality, reduced the time for data cleaning by 70%, and allowed for reporting on secondary outcomes. Conclusions Most sites maintained high quality records. In spite of this, data cleaning required significant amounts of time with little effect on program estimates of patient outcomes. LQAS conserves resources while maintaining sufficient data quality for program assessment and management to allow for quality patient

  12. Improving data quality and supervision of antiretroviral therapy sites in Malawi: an application of Lot Quality Assurance Sampling.

    Science.gov (United States)

    Hedt-Gauthier, Bethany L; Tenthani, Lyson; Mitchell, Shira; Chimbwandira, Frank M; Makombe, Simon; Chirwa, Zengani; Schouten, Erik J; Pagano, Marcello; Jahn, Andreas

    2012-07-09

    High quality program data is critical for managing, monitoring, and evaluating national HIV treatment programs. By 2009, the Malawi Ministry of Health had initiated more than 270,000 patients on HIV treatment at 377 sites. Quarterly supervision of these antiretroviral therapy (ART) sites ensures high quality care, but the time currently dedicated to exhaustive record review and data cleaning detracts from other critical components. The exhaustive record review is unlikely to be sustainable long term because of the resources required and increasing number of patients on ART. This study quantifies the current levels of data quality and evaluates Lot Quality Assurance Sampling (LQAS) as a tool to prioritize sites with low data quality, thus lowering costs while maintaining sufficient quality for program monitoring and patient care. In January 2010, a study team joined supervision teams at 19 sites purposely selected to reflect the variety of ART sites. During the exhaustive data review, the time allocated to data cleaning and data discrepancies were documented. The team then randomly sampled 76 records from each site, recording secondary outcomes and the time required for sampling. At the 19 sites, only 1.2% of records had discrepancies in patient outcomes and 0.4% in treatment regimen. However, data cleaning took 28.5 hours in total, suggesting that data cleaning for all 377 ART sites would require over 350 supervision-hours quarterly. The LQAS tool accurately identified the sites with the low data quality, reduced the time for data cleaning by 70%, and allowed for reporting on secondary outcomes. Most sites maintained high quality records. In spite of this, data cleaning required significant amounts of time with little effect on program estimates of patient outcomes. LQAS conserves resources while maintaining sufficient data quality for program assessment and management to allow for quality patient care.

  13. Study on quality assurance for high-level radioactive waste disposal project

    International Nuclear Information System (INIS)

    Takada, Susumu

    2005-01-01

    The U.S. Department of Energy (DOE) has developed comparatively detailed quality assurance requirements for the high-level radioactive waste disposal systems. Quality assurance is recognized as a key issue for confidence building and smooth implementation of the HLW program in Japan, and Japan is at an initial phase of repository development. Then the quality assurance requirements at site research and site selection, site characterization, and site suitability analysis used in the Yucca Mountain project were examined in detail and comprehensive descriptions were developed using flow charts. Additionally, the applicability to the Japan high-level radioactive waste disposal project was studied. The examination and study were performed for the following QA requirements: The requirements that have the relative importance at site research and site selection, site characterization, and site suitability analysis (such as planning and performing scientific investigations, sample control, data control, model development and use, technical report review, software control, and control of the electric management of data). The requirements that have the relative importance at the whole repository phases (such as quality assurance program, document control, and control of quality assurance records). (author)

  14. Crane RF accelerator for high current radiation damage studies

    International Nuclear Information System (INIS)

    Whitham, K.; Anamkath, H.; Evans, K.; Lyons, S.; Palmer, D.; Miller, R.; Treas, P.; Zante, T.

    1992-01-01

    An electron accelerator was designed and built for the Naval Weapons Support Center for transient radiation effects on electronics experiments and testing. The Crane L Band RF Electron Linac was designed to provide high currents over a wide range of pulse widths and energies. The energy extends to 60 MeV and pulse widths vary from a few ns to 10 μsec. Beam currents range from 20 amps in the short pulse case to 1.5 amps in the long pulse case. This paper describes the linac, its architecture, the e-gun and pulser, waveguides, klystrons and modulator, vacuum system, beam transport, and control systems. fig., tab

  15. Heavy-Ion Injector for the High Current Experiment

    Science.gov (United States)

    Bieniosek, F. M.; Henestroza, E.; Kwan, J. W.; Prost, L.; Seidl, P.

    2001-10-01

    We report on progress in development of the Heavy-Ion Injector at LBNL, which is being prepared for use as an injector for the High Current Experiment (HCX). It is composed of a 10-cm-diameter surface ionization source, an extraction diode, and an electrostatic quadrupole (ESQ) accelerator, with a typical operating current of 0.6 A of potassium ions at 1.8 MeV, and a beam pulse length of 4.5 microsecs. We have improved the Injector equipment and diagnostics, and have characterized the source emission and radial beam profiles at the diode and ESQ regions. We find improved agreement with EGUN predictions, and improved compatibility with the downstream matching section. Plans are to attach the matching section and the initial ESQ transport section of HCX. Results will be presented and compared with EGUN and WARP simulations.

  16. Effect of high-oxygen and high-carbon-dioxide atmospheres on strawberry flavor and other quality traits.

    Science.gov (United States)

    Pérez, A G; Sanz, C

    2001-05-01

    The effect of high-oxygen atmospheres on strawberry flavor was studied. Strawberry fruits (Fragariax ananassa Duch. cv. Camarosa) were stored at 8 degrees C in four different atmospheres: air, 5% O(2)/20% CO(2), 80% O(2)/20% CO(2), and 90% O(2)/10% CO(2). Changes in several quality parameters were evaluated. Atmospheres combining high O(2) and high CO(2) were the most effective in preventing fungal growth and enhancing strawberry firmness. Other quality parameters such as color, titrable acidity, sugars and organic acids distribution, off-flavor development, and aroma were only mildly affected by superatmospheric O(2) levels. After one week of storage, unexpected high contents of off-flavor related compounds were found in the 80% O(2)/20% CO(2) and 90% O(2)/10% CO(2) atmospheres. Evidence of an altered ester biosynthesis was also found in fruits stored under these high-O(2) atmospheres. Data obtained suggest that stress induced by high CO(2) and stress induced by high O(2) have an additive effect on strawberry flavor alteration.

  17. Electronically Tunable Current Controlled Current Conveyor Transconductance Amplifier-Based Mixed-Mode Biquadratic Filter with Resistorless and Grounded Capacitors

    Directory of Open Access Journals (Sweden)

    Hua-Pin Chen

    2017-03-01

    Full Text Available A new electronically tunable mixed-mode biquadratic filter with three current controlled current conveyor transconductance amplifiers (CCCCTAs and two grounded capacitors is proposed. With current input, the filter can realise lowpass (LP, bandpass (BP, highpass (HP, bandstop (BS and allpass (AP responses in current mode and LP, BP and HP responses in transimpedance mode. With voltage input, the filter can realise LP, BP, HP, BS and AP responses in voltage and transadmittance modes. Other attractive features of the mixed-mode biquadratic filter are (1 the use of two grounded capacitors, which is ideal for integrated circuit implementation; (2 orthogonal control of the quality factor (Q and resonance angular frequency (ωo for easy electronic tenability; (3 low input impedance and high output impedance for current signals; (4 high input impedance for voltage signal; (5 avoidance of need for component-matching conditions; (6 resistorless and electronically tunable structure; (7 low active and passive sensitivities; and (8 independent control of the voltage transfer gains without affecting the parameters ωo and Q.

  18. High quality long-wavelength lasers grown by atmospheric organometallic vapor phase epitaxy using tertiarybutylarsine

    International Nuclear Information System (INIS)

    Miller, B.I.; Young, M.G.; Oron, M.; Koren, U.; Kisker, D.

    1990-01-01

    High quality long-wavelength InGaAsP/InP lasers were grown by atmospheric organometallic vapor phase epitaxy using tertiarybutylarsine (TBA) as a substitute for AsH 3 . Electrical and photoluminescence measurements on InGaAs and InGaAsP showed that TBA-grown material was at least as good as AsH 3 material in terms of suitability for lasers. From two wafers grown by TBA, current thresholds I th as low as 11 mA were obtained for a 2-μm-wide semi-insulating blocking planar buried heterostructure laser lasing near 1.3 μm wavelength. The differential quantum efficiencies η D were as high as 21%/facet with a low internal loss α=21 cm -1 . In addition I th as low as 18 mA and η D as high as 18% have been obtained for multiplequantum well lasers at 1.54 μm wavelength. These results show that TBA might be used to replace AsH 3 without compromising on laser performance

  19. Study of pulse stretching in high current power supplies using multipulse techniques

    International Nuclear Information System (INIS)

    Trendler, R.C.

    1977-01-01

    Considerable interest exists at Fermilab to increase the pulse width of the Neutrino Focusing Horn to permit an increase in beam spill length from twenty (20) microseconds to one (1) millisecond. Two techniques to do this were examined: (1) a high current transformer, and (2) increased bank capacitance using the multi-power supply technique. The transformer is the most straightforward conceptually; it is, however, a complicated device requiring sizable changes to the existing horn power supply. This alternative is briefly reviewed. The second scheme involves pulsing a 20 kv 200 ka power supply to establish the required load current and then maintaining this current by the sequential pulsing of a number of low voltage high current power supplies. This alternative is discussed in detail with the results of tests performed on the Fermilab Focusing Horn System

  20. [Extensive injuries due to high-tension electrical current].

    Science.gov (United States)

    Tomásek, D; Königová, R; Snupárek, Z

    1989-03-01

    The authors submit a case of severe injury with high tension electric current. They emphasize the necessity of prevention of this injury which occurs most frequently when transformer stations are not adequately safeguarded, in case of inadequate protection when approaching trolley wires on the railway track, and when safety principles are not respected during work on the railway. The authors draw attention to the importance of immediate resuscitation and multidisciplinary comprehensive care.

  1. Generation of sheet currents by high frequency fast MHD waves

    Energy Technology Data Exchange (ETDEWEB)

    Núñez, Manuel, E-mail: mnjmhd@am.uva.es

    2016-07-01

    The evolution of fast magnetosonic waves of high frequency propagating into an axisymmetric equilibrium plasma is studied. By using the methods of weakly nonlinear geometrical optics, it is shown that the perturbation travels in the equatorial plane while satisfying a transport equation which enables us to predict the time and location of formation of shock waves. For plasmas of large magnetic Prandtl number, this would result into the creation of sheet currents which may give rise to magnetic reconnection and destruction of the original equilibrium. - Highlights: • Regular solutions of quasilinear hyperbolic systems may evolve into shocks. • The shock location is found for high frequency fast MHD waves. • The result is applied to static axisymmetric equilibria. • The previous process may lead to the formation of sheet currents and destruction of the equilibrium.

  2. A safe inexpensive method to isolate high quality plant and fungal ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-08-18

    Aug 18, 2008 ... quality DNA from plant and fungal species. This method uses potassium acetate to remove proteins and polysaccharides in an SDS extraction buffer. Further DNA purification is achieved using a low salt. CTAB treatment. This SDS/CTAB protocol was used to isolate high quality genomic DNA subject to.

  3. The Challenges of Data Quality and Data Quality Assessment in the Big Data Era

    Directory of Open Access Journals (Sweden)

    Li Cai

    2015-05-01

    Full Text Available High-quality data are the precondition for analyzing and using big data and for guaranteeing the value of the data. Currently, comprehensive analysis and research of quality standards and quality assessment methods for big data are lacking. First, this paper summarizes reviews of data quality research. Second, this paper analyzes the data characteristics of the big data environment, presents quality challenges faced by big data, and formulates a hierarchical data quality framework from the perspective of data users. This framework consists of big data quality dimensions, quality characteristics, and quality indexes. Finally, on the basis of this framework, this paper constructs a dynamic assessment process for data quality. This process has good expansibility and adaptability and can meet the needs of big data quality assessment. The research results enrich the theoretical scope of big data and lay a solid foundation for the future by establishing an assessment model and studying evaluation algorithms.

  4. Soil environmental quality in greenhouse vegetable production systems in eastern China: Current status and management strategies.

    Science.gov (United States)

    Hu, Wenyou; Zhang, Yanxia; Huang, Biao; Teng, Ying

    2017-03-01

    Greenhouse vegetable production (GVP) has become an important source of public vegetable consumption and farmers' income in China. However, various pollutants can be accumulated in GVP soils due to the high cropping index, large agricultural input, and closed environment. Ecological toxicity caused by excessive pollutants' accumulation can then lead to serious health risks. This paper was aimed to systematically review the current status of soil environmental quality, analyze their impact factors, and consequently to propose integrated management strategies for GVP systems. Results indicated a decrease in soil pH, soil salinization, and nutrients imbalance in GVP soils. Fungicides, remaining nutrients, antibiotics, heavy metals, and phthalate esters were main pollutants accumulating in GVP soils comparing to surrounding open field soils. Degradation of soil ecological function, accumulation of major pollutants in vegetables, deterioration of neighboring water bodies, and potential human health risks has occurred due to the changes of soil properties and accumulation of pollutants such as heavy metals and fungicides in soils. Four dominant factors were identified leading to the above-mentioned issues including heavy application of agricultural inputs, outmoded planting styles with poor environmental protection awareness, old-fashion regulations, unreasonable standards, and ineffective supervisory management. To guarantee a sustainable GVP development, several strategies were suggested to protect and improve soil environmental quality. Implementation of various strategies not only requires the concerted efforts among different stakeholders, but also the whole lifecycle assessment throughout the GVP processes as well as effective enforcement of policies, laws, and regulations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Ground Return Current Behaviour in High Voltage Alternating Current Insulated Cables

    Directory of Open Access Journals (Sweden)

    Roberto Benato

    2014-12-01

    Full Text Available The knowledge of ground return current in fault occurrence plays a key role in the dimensioning of the earthing grid of substations and of cable sealing end compounds, in the computation of rise of earth potential at substation sites and in electromagnetic interference (EMI on neighbouring parallel metallic conductors (pipes, handrails, etc.. Moreover, the ground return current evaluation is also important in steady-state regime since this stray current can be responsible for EMI and also for alternating current (AC corrosion. In fault situations and under some assumptions, the ground return current value at a substation site can be computed by means of k-factors. The paper shows that these simplified and approximated approaches have a lot of limitations and only multiconductor analysis can show the ground return current behaviour along the cable (not only the two end values both in steady-state regime and in short circuit occurrence (e.g., phase-to-ground and phase-to-phase-to-ground. Multiconductor cell analysis (MCA considers the cable system in its real asymmetry without simplified and approximated hypotheses. The sensitivity of ground return current on circuit parameters (cross-bonding box resistances, substation earthing resistances, soil resistivity is presented in the paper.

  6. Wellbeing Understanding in High Quality Healthcare Informatics and Telepractice.

    Science.gov (United States)

    Fiorini, Rodolfo A; De Giacomo, Piero; L'Abate, Luciano

    2016-01-01

    The proper use of healthcare informatics technology and multidimensional conceptual clarity are fundamental to create and boost outstanding clinical and telepractice results. Avoiding even terminology ambiguities is mandatory for high quality of care service. For instance, well-being or wellbeing is a different way to write the same concept only, or there is a good deal of ambiguity around the meanings of these terms the way they are written. In personal health, healthcare and healthcare informatics, this kind of ambiguity and lack of conceptual clarity has been called out repeatedly over the past 50 years. It is time to get the right, terse scenario. We present a brief review to develop and achieve ultimate wellbeing understanding for practical high quality healthcare informatics and telepractice application. This article presents an innovative point of view on deeper wellbeing understanding towards its increased clinical effective application.

  7. Construction of High-Quality Camel Immune Antibody Libraries.

    Science.gov (United States)

    Romão, Ema; Poignavent, Vianney; Vincke, Cécile; Ritzenthaler, Christophe; Muyldermans, Serge; Monsion, Baptiste

    2018-01-01

    Single-domain antibodies libraries of heavy-chain only immunoglobulins from camelids or shark are enriched for high-affinity antigen-specific binders by a short in vivo immunization. Thus, potent binders are readily retrieved from relatively small-sized libraries of 10 7 -10 8 individual transformants, mostly after phage display and panning on a purified target. However, the remaining drawback of this strategy arises from the need to generate a dedicated library, for nearly every envisaged target. Therefore, all the procedures that shorten and facilitate the construction of an immune library of best possible quality are definitely a step forward. In this chapter, we provide the protocol to generate a high-quality immune VHH library using the Golden Gate Cloning strategy employing an adapted phage display vector where a lethal ccdB gene has to be substituted by the VHH gene. With this procedure, the construction of the library can be shortened to less than a week starting from bleeding the animal. Our libraries exceed 10 8 individual transformants and close to 100% of the clones harbor a phage display vector having an insert with the length of a VHH gene. These libraries are also more economic to make than previous standard approaches using classical restriction enzymes and ligations. The quality of the Nanobodies that are retrieved from immune libraries obtained by Golden Gate Cloning is identical to those from immune libraries made according to the classical procedure.

  8. Adherence to guidelines for cardiovascular screening in current high school preparticipation evaluation forms.

    Science.gov (United States)

    Rausch, Christopher M; Phillips, George C

    2009-10-01

    We compared the content of the cardiac screening questions on US state high school athletic association preparticipation evaluation forms with current consensus recommendations. We reviewed the high school athletic association's approved, recommended, or required sports preparticipation form from each of the 50 US states and the District of Columbia, and compared the content of the personal and family history components with current recommendations for cardiac screening questions. We found that 85% of the preparticipation forms in current use contain all elements of the formerly recommended guidelines, but only 17% contain all elements of the new consensus guidelines. We conclude that although there appears to be some improvement in the content of the preparticipation forms in current use compared with previous studies, the vast majority of these forms are incomplete compared with current consensus guidelines.

  9. Air Quality Standards for Particulate Matter (PM) at high altitude cities

    International Nuclear Information System (INIS)

    Bravo Alvarez, H.; Sosa Echeverria, R.; Sanchez Alvarez, P.; Krupa, S.

    2013-01-01

    The Air Quality Standards for Particulate Matter (PM) at high altitude urban areas in different countries, must consider the pressure and temperature due to the effect that these parameters have on the breath volume. This paper shows the importance to correct Air Quality Standards for PM considering pressure and temperature at different altitudes. Specific factors were suggested to convert the information concerning PM, from local to standard conditions, and adjust the Air Quality Standards for different high altitudes cities. The correction factors ranged from: 1.03 for Santiago de Chile to 1.47 for El Alto Bolivia. Other cities in this study include: Mexico City, México; La Paz, Bolivia; Bogota, Cali and Medellin, Colombia; Quito, Ecuador and Cuzco, Peru. If these corrections are not considered, the atmospheric concentrations will be underestimated. - Highlights: ► AQS for particulate matter concentrations adjusted by pressure and temperature. ► Particulate matter concentrations can be underestimated in high altitude Cities. ► Particulate matter concentrations must be compared under the same conditions. - In order to compare high altitude atmospheric PM concentrations with AQS, one must consider T and P of the sampling site.

  10. Programmable current source for diode lasers stabilized optical fiber

    International Nuclear Information System (INIS)

    Gomez, J.; Camas, J.; Garcia, L.

    2012-01-01

    In this paper, we present the electronic design of a programmable stabilized current source. User can access to the source through a password, which, it has a database with the current and voltage operating points. This source was successfully used as current source in laser diode in optical fiber sensors. Variations in the laser current were carried out by a monitoring system and a control of the Direct Current (DC), which flowing through a How land source with amplifier. The laser current can be stabilized with an error percent of ± 1 μA from the threshold current (Ith) to its maximum operation current (Imax) in DC mode. The proposed design is reliable, cheap, and its output signal of stabilized current has high quality. (Author)

  11. Stainless steel fabrication for high quality requirements in the nuclear industry

    International Nuclear Information System (INIS)

    Wareing, A.J.

    1990-01-01

    In this paper the author explains the welding procedures and practices adopted within the nuclear industry to achieve the high quality and standards of welds required. The changeover to mechanised welding, orbital TIG welding and synergic MIG welding, has resulted in consistent achievement of high quality standards as well as optimising the productivity. However, the use of mechanised welding machines does require the welder operating them to be fully trained and qualified. The formally organised training courses are described and the cost savings and production rates achieved by utilising the mechanised method are discussed. (author)

  12. Energy confinement in a high-current reversed field pinch

    International Nuclear Information System (INIS)

    An, Z.G.; Lee, G.S.; Diamond, P.H.

    1985-07-01

    The ion temperature gradient driven (eta/sub i/) mode is proposed as a candidate for the cause of anomalous transport in high current reversed field pinches. A 'four-field' fluid model is derived to describe the coupled nonlinear evolution of resistive interchange and eta/sub i/ modes. A renormalized theory is discussed, and the saturation level of the fluctuations is analytically estimated. Transport scalings are obtained, and their implications discussed. In particular, these results indicate that pellet injection is a potentially viable mechanism for improving energy confinement in a high temperature RFP

  13. Characteristics of PEMFC operating at high current density with low external humidification

    International Nuclear Information System (INIS)

    Fan, Linhao; Zhang, Guobin; Jiao, Kui

    2017-01-01

    Highlights: • PEMFC with low humidity and high current density is studied by numerical simulation. • At high current density, water production lowers external humidification requirement. • A steady anode circulation status without external humidification is demonstrated. • The corresponding detailed internal water transfer path in the PEMFC is illustrated. • Counter-flow is superior to co-flow at low anode external humidification. - Abstract: A three-dimensional multiphase numerical model for proton exchange membrane fuel cell (PEMFC) is developed to study the fuel cell performance and water transport properties with low external humidification. The results show that the sufficient external humidification is necessary to prevent the polymer electrolyte dehydration at low current density, while at high current density, the water produced in cathode CL is enough to humidify the polymer electrolyte instead of external humidification by flowing back and forth between the anode and cathode across the membrane. Furthermore, a steady anode circulation status without external humidification is demonstrated in this study, of which the detailed internal water transfer path is also illustrated. Additionally, it is also found that the water balance under the counter-flow arrangement is superior to co-flow at low anode external humidification.

  14. Critical current measurements of high Tc superconductors in a scanning low temperature cryostat

    International Nuclear Information System (INIS)

    Telschow, K.L.; O'Brien, T.K.

    1991-01-01

    Maintaining uniformity of properties over long distances is one of the fabrication problems encountered with the new high T c superconductors. Uniform properties are crucial in long tapes or wires with high critical current since local nonuniformities can limit the current carrying capacity of the whole piece. Transport critical currents in high T c superconductors are conventionally measured with the contact 4-point probe DC current-voltage technique. This technique requires contact with the sample and and spatially averages over the region between the two voltage contacts. Two techniques have been used to infer the critical state model. The first uses the net magnetization of a suitably shaped sample in an external magnetic field. The second combines a DC magnetic field with AC induced currents to infer spatial flux profiles. The AC magnetization technique offers an advantage in that it is noncontacting; however, it also averages the measurement over a large area and requires that the sample be shaped and positioned such that it exhibits zero demagnetizing factor. This paper describes a measurement technique and a scanning cryostat assembly that are capable of determining local critical current in a tape or wire with high resolution and without any direct sample electrical contact. A small compensated coil was used to induce AC currents in slab-shaped samples. The coil was situated near the surface on one side of the slab. With this method, the AC probe can be used as a noncontacting dissipation probe, replacing the voltage probe in the 4-point contact method, when an externally driven transport current is used, or by itself as a local critical state generator and dissipation detector. The results are shown to be meaningful even when the internal magnetic field is not uniform due to shape demagnetizing effects. 10 refs., 5 figs

  15. High Resolution Eddy-Current Wire Testing Based on a Gmr Sensor-Array

    Science.gov (United States)

    Kreutzbruck, Marc; Allweins, Kai; Strackbein, Chris; Bernau, Hendrick

    2009-03-01

    Increasing demands in materials quality and cost effectiveness have led to advanced standards in manufacturing technology. Especially when dealing with high quality standards in conjunction with high throughput quantitative NDE techniques are vital to provide reliable and fast quality control systems. In this work we illuminate a modern electromagnetic NDE approach using a small GMR sensor array for testing superconducting wires. Four GMR sensors are positioned around the wire. Each GMR sensor provides a field sensitivity of 200 pT/√Hz and a spatial resolution of about 100 μm. This enables us to detect under surface defects of 100 μm in size in a depth of 200 μm with a signal-to-noise ratio of better than 400. Surface defects could be detected with a SNR of up to 10,000. Besides this remarkably SNR the small extent of GMR sensors results in a spatial resolution which offers new visualisation techniques for defect localisation, defect characterization and tomography-like mapping techniques. We also report on inverse algorithms based on either a Finite Element Method or an analytical approach. These allow for accurate defect localization on the urn scale and an estimation of the defect size.

  16. High current density M-type cathodes for vacuum electron devices

    International Nuclear Information System (INIS)

    Li Ji; Yu Zhiqiang; Shao Wensheng; Zhang Ke; Gao Yujuan; Yuan Haiqing; Wang Hui; Huang Kaizhi; Chen Qilue; Yan Suqiu; Cai Shaolun

    2005-01-01

    We investigated high current density emission capabilities of M-type cathodes used for vacuum electron devices (VEDs). The experimental results of emission and lifetime evaluating in both close-spaced diode structure and electron gun testing vehicles are given. Emission current densities measured in the diode structure at 1020 deg. C Br in the CW mode were above 10 A/cm 2 ; while in electron gun testing vehicles, emission current densities were above 8 A/cm 2 in CW mode and above 32 A/cm 2 in pulsed mode, respectively. The current density above 94 A/cm 2 has been acquired in no. 0306 electron gun vehicle while the practical temperature is 1060 deg. C Br . For a comparison some of the data from I-scandate cathodes are presented. Finally, several application examples in practical travelling wave tubes (TWTs) and multi beam klystrons (MBKs) are also reported

  17. High current density, cryogenically cooled sliding electrical joint development

    International Nuclear Information System (INIS)

    Murray, H.

    1986-09-01

    In the past two years, conceptual designs for fusion energy research devices have focussed on compact, high magnetic field configurations. The concept of sliding electrical joints in the large magnets allows a number of technical advantages including enhanced mechanical integrity, remote maintainability, and reduced project cost. The rationale for sliding electrical joints is presented. The conceptual configuration for this generation of experimental devices is highlghted by an ∼ 20 T toroidal field magnet with a flat top conductor current of ∼ 300 kA and a sliding electrical joint with a gross current density of ∼ 0.6 kA/cm 2 . A numerical model was used to map the conductor current distribution as a function of time and position in the conductor. A series of electrical joint arrangements were produced against the system code envelope constraints for a specific version of the Ignition Studies Project (ISP) which is designated as 1025

  18. Excitation of plasma waves by nonlinear currents induced by a high-frequency electromagnetic pulse

    Energy Technology Data Exchange (ETDEWEB)

    Grishkov, V. E.; Uryupin, S. A., E-mail: uryupin@sci.lebedev.ru [Russian Academy of Sciences, Lebedev Physical Institute (Russian Federation)

    2017-03-15

    Excitation of plasma waves by nonlinear currents induced by a high-frequency electromagnetic pulse is analyzed within the kinetic approach. It is shown that the most efficient source of plasma waves is the nonlinear current arising due to the gradient of the energy density of the high-frequency field. Generation of plasma waves by the drag current is usually less efficient but not negligibly small at relatively high frequencies of electron–ion collisions. The influence of electron collisions on the excitation of plasma waves by pulses of different duration is described quantitatively.

  19. Effect of a superconducting coil as a fault current limiter on current density distribution in BSCCO tape after an over-current pulse

    International Nuclear Information System (INIS)

    Tallouli, M; Yamaguchi, S.; Shyshkin, O.

    2017-01-01

    The development of power transmission lines based on long-length high temperature superconducting (HTS) tapes is complicated and technically challenging task. A serious problem for transmission line operation could become HTS power cable damage due to over-current pulse conditions. To avoid the cable damage in any urgent case the superconducting coil technology, i.e. superconductor fault current limiter (SFCL) is required. Comprehensive understanding of the current density characteristics of HTS tapes in both cases, either after pure over-current pulse or after over-current pulse limited by SFCL, is needed to restart or to continue the operation of the power transmission line. Moreover, current density distribution along and across the HTS tape provides us with the sufficient information about the quality of the tape performance in different current feeding regimes. In present paper we examine BSCCO HTS tape under two current feeding regimes. The first one is 100A feeding preceded by 900A over-current pulse. In this case none of tape protection was used. The second scenario is similar to the fist one but SFCL is used to limit an over-current value. For both scenarios after the pulse is gone and the current feeding is set up at 100A we scan magnetic field above the tape by means of Hall probe sensor. Then the feeding is turned of and the magnetic field scanning is repeated. Using the inverse problem numerical solver we calculate the corresponding direct and permanent current density distributions during the feeding and after switch off. It is demonstrated that in the absence of SFCL the current distribution is highly peaked at the tape center. At the same time the current distribution in the experiment with SFCL is similar to that observed under normal current feeding condition. The current peaking in the first case is explained by the effect of an opposite electric field induced at the tape edges during the overcurrent pulse decay, and by degradation of

  20. Run-away electrons and plasma pinching in a high-current diode

    International Nuclear Information System (INIS)

    Ivanenkov, G.V.

    1984-01-01

    The electrons run-away process in space-confined plasma with current is considered. It has been found that the effect of the proper magnetic field of a current leads to appearance, in add tion to the Dreicer mechanism, of other run-away mechanism in the process of radial oscillations of electrons accelerating near the axis. The appearance of run-away electrons from a thermal velocities region occurs in the course of collisions as well as radial drift. The thresholds of Dreicer run-away and drift are determined. The conditions of formation of Z-pinch current envelope and its collisionless compression by the ''snow plough'' type for the 10-100 ns of high-current accelerator pulse duration are elucidated