WorldWideScience

Sample records for high pressure plasma

  1. Basic Studies on High Pressure Air Plasmas

    Science.gov (United States)

    2006-08-30

    AOM is screwed to its mounting system, whereas the visible AOM is just glued using nail polish . noplasnoir2. phas- royenne aur :50 soua-dom Decim...part of the plasma near- UV emission spectrum for a 3 mm gap and a 20 mA current. Molecular bands can be identified: NO (y system, 200-260 nm), OH (0...200 210 220 230 240 250 260 300 310 320 330 340 350 360 Wavelength (nm) Wavelength (nm) Figure 9. Plasma UV emission spectrum A simulation of the

  2. Thermal analysis of high pressure micro plasma discharge

    Science.gov (United States)

    Mobli, Mostafa

    High pressure micro plasma discharge has been at the center of interest in recent years, because of their vast applications, ease of access and cost efficiency. This attributes to atmospheric discharges that are generated in ambient conditions and therefore can be readily applicable to everyday use. The absence of vacuum makes these high pressure discharges to be inexpensive to operate. Despite the ease of operation, the high pressure is a source of enhanced gas heating as the gas temperature cannot be controlled by diffusion alone. Gas heating is therefore an important factor when it comes to the simulation of high pressure micro plasma discharge, unlike their low pressure counterpart where the heat generation is almost negligible. Low pressure discharge due to their low degree of collisionality generates ionic species and electrons at small concentrations, whereas high pressure discharge due to their higher gas density produces ions and electrons at higher concentrations which is a direct consequence of increase collision. The higher gas density and consequential large concentration of ionic species and electron contributes directly to higher heat generation rates. . In this thesis the gas temperature transport of high pressure micro plasma discharge has been studied with a special focus on the heat source terms, temperature boundary conditions, temperature distribution in the solid phase electrodes and the gas phase and their overall influence on the plasma characteristics. For this purpose a multi-physics mathematical model has been developed that comprised of a plasma module, neutral gas temperature module, external circuit module and conjugate heat transfer module. The plasma module consisted of conservation of the different ionic, electronically excited species, radicals, neutrals and electrons, conservation of the electron temperature, and electric field. The external circuit module resolved the coupled driving circuit comprised of a voltage source, ballast

  3. High-performance simulations for atmospheric pressure plasma reactor

    Science.gov (United States)

    Chugunov, Svyatoslav

    Plasma-assisted processing and deposition of materials is an important component of modern industrial applications, with plasma reactors sharing 30% to 40% of manufacturing steps in microelectronics production. Development of new flexible electronics increases demands for efficient high-throughput deposition methods and roll-to-roll processing of materials. The current work represents an attempt of practical design and numerical modeling of a plasma enhanced chemical vapor deposition system. The system utilizes plasma at standard pressure and temperature to activate a chemical precursor for protective coatings. A specially designed linear plasma head, that consists of two parallel plates with electrodes placed in the parallel arrangement, is used to resolve clogging issues of currently available commercial plasma heads, as well as to increase the flow-rate of the processed chemicals and to enhance the uniformity of the deposition. A test system is build and discussed in this work. In order to improve operating conditions of the setup and quality of the deposited material, we perform numerical modeling of the plasma system. The theoretical and numerical models presented in this work comprehensively describe plasma generation, recombination, and advection in a channel of arbitrary geometry. Number density of plasma species, their energy content, electric field, and rate parameters are accurately calculated and analyzed in this work. Some interesting engineering outcomes are discussed with a connection to the proposed setup. The numerical model is implemented with the help of high-performance parallel technique and evaluated at a cluster for parallel calculations. A typical performance increase, calculation speed-up, parallel fraction of the code and overall efficiency of the parallel implementation are discussed in details.

  4. Simulation of plasma loading of high-pressure RF cavities

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Kwangmin [Brookhaven; Samulyak, Roman [SUNY, Stony Brook; Yonehara, Katsuya [Fermilab; Freemire, Ben [Northern Illinois U.

    2018-01-11

    Muon beam-induced plasma loading of radio-frequency (RF) cavities filled with high pressure hydrogen gas with 1% dry air dopant has been studied via numerical simulations. The electromagnetic code SPACE, that resolves relevant atomic physics processes, including ionization by the muon beam, electron attachment to dopant molecules, and electron-ion and ion-ion recombination, has been used. Simulations studies have been performed in the range of parameters typical for practical muon cooling channels.

  5. Plasma pressure and particle loss studies in the Pilot-PSI high flux linear plasma generator

    Directory of Open Access Journals (Sweden)

    K. Ješko

    2017-08-01

    Full Text Available Plasma detachment in tokamak divertors reduces the particle and power fluxes to the plasma facing components and is essential for successful operation of ITER. The linear plasma generator Pilot-PSI can produce a high density (∼1021 m−3, low temperature (∼1eV plasma which is similar to that expected at the ITER divertor strike-points during the partially detached regime [1]. Given the simple geometry of the device, Pilot-PSI allows to diagnose the plasma beam at multiple axial positions. In this study, the incoherent Thomson scattering (TS diagnostic [2] is exploited to measure the radial plasma Te and ne profiles at two locations of the hydrogen plasma beam: near the plasma source (upstream and 2cm from the target plate. At the target, the TS measurements are supported by an embedded Langmuir probe. These measurements prove the existence of parallel plasma pressure loss as well as particle loss, confirming that physical processes believed to cause detachment in tokamak divertors also hold in Pilot-PSI (ion-neutral friction, volume recombination. It is found that the fractional reduction of the plasma pressure varies between ∼4 and ∼5000, depending strongly on the pressure of the background neutrals. The importance of individual loss channels is discussed.

  6. Suppression of diamagnetism by neutrals pressure in partially ionized, high-beta plasma

    Science.gov (United States)

    Shinohara, Shunjiro; Kuwahara, Daisuke; Yano, Kazuki; Fruchtman, Amnon

    2016-12-01

    Suppression of diamagnetism in a partially ionized plasma with high beta was experimentally investigated by the use of Langmuir and Hall sensor probes, focusing on a neutrals pressure effect. The plasma beta, which is the ratio of plasma to vacuum magnetic pressures, varied from ˜1% to >100% while the magnetic field varied from ˜120 G to ˜1 G. Here, a uniform magnetized argon plasma was operated mostly in an inductive mode, using a helicon plasma source of the Large Helicon Plasma Device [S. Shinohara et al., Phys. Plasmas 16, 057104 (2009)] with a diameter of 738 mm and an axial length of 4860 mm. Electron density varied from 5 × 1015 m-3 to diamagnetic effect was smaller than that expected by the plasma beta. This suppressed diamagnetism is explained by the neutrals pressure replacing magnetic pressure in balancing plasma pressure. Diamagnetism is weakened if neutrals pressure is comparable to the plasma pressure and if the coupling of plasma and neutrals pressures by ion-neutral collisions is strong enough.

  7. Cancer therapy using non-thermal atmospheric pressure plasma with ultra-high electron density

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Hiromasa [Institute of Innovation for Future Society, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Center for Advanced Medicine and Clinical Research, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Mizuno, Masaaki [Center for Advanced Medicine and Clinical Research, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Toyokuni, Shinya [Department of Pathology and Biological Responses, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Maruyama, Shoichi [Department of Nephrology, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Kodera, Yasuhiro [Department of Gastroenterological Surgery (Surgery II), Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Terasaki, Hiroko [Department of Ophthalmology, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Adachi, Tetsuo [Laboratory of Clinical Pharmaceutics, Gifu Pharmaceutical University, 501-1196 Gifu (Japan); Kato, Masashi [Department of Occupational and Environmental Health, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Kikkawa, Fumitaka [Department of Obstetrics and Gynecology, Nagoya University Graduate School of Medicine, Tsurumai-cho 65, Showa-ku, Nagoya 466-8550 (Japan); Hori, Masaru [Institute of Innovation for Future Society, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan)

    2015-12-15

    Cancer therapy using non-thermal atmospheric pressure plasma is a big challenge in plasma medicine. Reactive species generated from plasma are key factors for treating cancer cells, and thus, non-thermal atmospheric pressure plasma with high electron density has been developed and applied for cancer treatment. Various cancer cell lines have been treated with plasma, and non-thermal atmospheric plasma clearly has anti-tumor effects. Recent innovative studies suggest that plasma can both directly and indirectly affect cells and tissues, and this observation has widened the range of applications. Thus, cancer therapy using non-thermal atmospheric pressure plasma is promising. Animal experiments and understanding the mode of action are essential for clinical application in the future. A new academic field that combines plasma science, the biology of free radicals, and systems biology will be established.

  8. Plasma pressure and particle loss studies in the Pilot-PSI high flux linear plasma generator

    NARCIS (Netherlands)

    Jesko, K.; van der Meiden, H. J.; Gunn, J. P.; Vernimmen, J. W. M.; De Temmerman, G.

    2017-01-01

    Plasma detachment in tokamak divertors reduces the particle and power fluxes to the plasma facing components and is essential for successful operation of ITER. The linear plasma generator Pilot-PSI can produce a high density (∼1021 m−3), low temperature (∼1 eV) plasma which is similar to that

  9. Influence of low and high pressure baroreceptors on plasma renin activity in humans

    Science.gov (United States)

    Mark, A. L.; Abboud, F. M.; Fitz, A. E.

    1977-01-01

    The effects of low and high pressure baroreceptors on plasma renin activity (immunoassay) were evaluated using graded lower body suction (LBS) in six healthy men. LBS at -10 and -20 mmHg for 10 min decreased central venous pressure without changing arterial pressure and thereby presumably reduced low but not high pressure baroreceptor inhibition of renin release. LBS at these levels produced forearm vasoconstriction, but did not increase renin. LBS at -40 mmHG decreased central venous and arterial pulse pressure and thus reduced both low and high pressure baroreceptor inhibition. LBS at this level produced forearm vasoconstriction and tachycardia and increased renin. In summary, reduction in low pressure baroreceptor inhibition in humans did not increase renin in the presence of physiological tonic inhibition from high pressure baroreceptors. Increases in renin did not occur until there was combined reduction of high and low pressure baroreceptor inhibition on plasma renin activity.

  10. Extremely high-pressure generation and compression with laser implosion plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Shigemori, K.; Hironaka, Y.; Nagatomo, H.; Fujioka, S.; Azechi, H. [Institute of Laser Engineering, Osaka University, 2-6 Yamada-Oka, Suita, Osaka 565-0871 (Japan); Sunahara, A. [Institute for Laser Technology, 2-6 Yamada-Oka, Suita, Osaka 565-0871 (Japan); Kadono, T. [University of Occupational and Environmental Health, 1-1 Iseigaoka, Yahata-nishi-ku, Kitakyushu, Fukuoka 807-8555 (Japan); Shimizu, K. [Center for Quantum Science and Technology under Extreme Conditions, Osaka University, 1-3 Machikaneyama-Cho, Toyonaka 560-0831 (Japan)

    2013-05-06

    We have tested a scheme for using laser implosion plasmas to generate pressures in the gigabar (100 TPa) regime. Cone-in-shell targets employed in fast ignition of inertial confinement fusion were irradiated to create a high-pressure source for compression of materials. The imploded plasmas pushed a foil embedded on the tip of a cone. The pressure was estimated from the shock velocity into the material; the shock velocity was obtained from an optical measurement. The measured shock velocity of the foil was above 100 km/s, corresponding to a pressure greater than 1 Gbar.

  11. Atmospheric pressure plasma jet with high-voltage power supply based on piezoelectric transformer.

    Science.gov (United States)

    Babij, Michał; Kowalski, Zbigniew W; Nitsch, Karol; Silberring, Jerzy; Gotszalk, Teodor

    2014-05-01

    The dielectric barrier discharge plasma jet, an example of the nonthermal atmospheric pressure plasma jet (APPJ), generates low-temperature plasmas that are suitable for the atomization of volatile species and can also be served as an ionization source for ambient mass and ion mobility spectrometry. A new design of APPJ for mass spectrometry has been built in our group. In these plasma sources magnetic transformers (MTs) and inductors are typically used in power supplies but they present several drawbacks that are even more evident when dealing with high-voltage normally used in APPJs. To overcome these disadvantages, high frequency generators with the absence of MT are proposed in the literature. However, in the case of miniaturized APPJs these conventional power converters, built of ferromagnetic cores and inductors or by means of LC resonant tank circuits, are not so useful as piezoelectric transformer (PT) based power converters due to bulky components and small efficiency. We made and examined a novel atmospheric pressure plasma jet with PT supplier served as ionization source for ambient mass spectrometry, and especially mobile spectrometry where miniaturization, integration of components, and clean plasma are required. The objective of this paper is to describe the concept, design, and implementation of this miniaturized piezoelectric transformer-based atmospheric pressure plasma jet.

  12. Atmospheric Pressure Plasma: A High-Performance Tool for the Efficient Removal of Biofilms

    Science.gov (United States)

    Fricke, Katja; Koban, Ina; Tresp, Helena; Jablonowski, Lukasz; Schröder, Karsten; Kramer, Axel; Weltmann, Klaus-Dieter; von Woedtke, Thomas; Kocher, Thomas

    2012-01-01

    Introduction The medical use of non-thermal physical plasmas is intensively investigated for sterilization and surface modification of biomedical materials. A further promising application is the removal or etching of organic substances, e.g., biofilms, from surfaces, because remnants of biofilms after conventional cleaning procedures are capable to entertain inflammatory processes in the adjacent tissues. In general, contamination of surfaces by micro-organisms is a major source of problems in health care. Especially biofilms are the most common type of microbial growth in the human body and therefore, the complete removal of pathogens is mandatory for the prevention of inflammatory infiltrate. Physical plasmas offer a huge potential to inactivate micro-organisms and to remove organic materials through plasma-generated highly reactive agents. Method In this study a Candida albicans biofilm, formed on polystyrene (PS) wafers, as a prototypic biofilm was used to verify the etching capability of the atmospheric pressure plasma jet operating with two different process gases (argon and argon/oxygen mixture). The capability of plasma-assisted biofilm removal was assessed by microscopic imaging. Results The Candida albicans biofilm, with a thickness of 10 to 20 µm, was removed within 300 s plasma treatment when oxygen was added to the argon gas discharge, whereas argon plasma alone was practically not sufficient in biofilm removal. The impact of plasma etching on biofilms is localized due to the limited presence of reactive plasma species validated by optical emission spectroscopy. PMID:22880025

  13. Atmospheric pressure plasma: a high-performance tool for the efficient removal of biofilms.

    Directory of Open Access Journals (Sweden)

    Katja Fricke

    Full Text Available INTRODUCTION: The medical use of non-thermal physical plasmas is intensively investigated for sterilization and surface modification of biomedical materials. A further promising application is the removal or etching of organic substances, e.g., biofilms, from surfaces, because remnants of biofilms after conventional cleaning procedures are capable to entertain inflammatory processes in the adjacent tissues. In general, contamination of surfaces by micro-organisms is a major source of problems in health care. Especially biofilms are the most common type of microbial growth in the human body and therefore, the complete removal of pathogens is mandatory for the prevention of inflammatory infiltrate. Physical plasmas offer a huge potential to inactivate micro-organisms and to remove organic materials through plasma-generated highly reactive agents. METHOD: In this study a Candida albicans biofilm, formed on polystyrene (PS wafers, as a prototypic biofilm was used to verify the etching capability of the atmospheric pressure plasma jet operating with two different process gases (argon and argon/oxygen mixture. The capability of plasma-assisted biofilm removal was assessed by microscopic imaging. RESULTS: The Candida albicans biofilm, with a thickness of 10 to 20 µm, was removed within 300 s plasma treatment when oxygen was added to the argon gas discharge, whereas argon plasma alone was practically not sufficient in biofilm removal. The impact of plasma etching on biofilms is localized due to the limited presence of reactive plasma species validated by optical emission spectroscopy.

  14. Conversion of high-pressure carbon dioxide by laser-induced plasma

    Science.gov (United States)

    Goto, Taku; Suzuki, Hirotaka; Koizumi, Masato; Ito, Tsuyohito

    2016-09-01

    In the conversion process of CO2 ->CO + 1/2 O2 by means of plasma, an atomic oxygen is often observed as the intermediate state. As the following reaction forming 1/2 O2 from O is exothermic, unless the energy is reused, the existence of O atoms results in a lower conversion efficiency of the process. Thus, we are trying to find a pathway which forms 1/2 O2 directly, by contribution of the high pressure, which hopefully boosts the conversion efficiency. In this study, we produce plasma by nanosecond-pulsed laser focused on various metallic targets (Sn, Zn and Cu) in pressurized CO2 environments. The results indicate that the energy conversion efficiency depends on the pressure. In addition, applying a target results in a higher energy conversion efficiency than that without targets, and the efficiency depends on the target materials. We currently believe that the target materials modify the initial density of plasma and the pressure controls the following plasma dynamics. The details will be presented at the conference.

  15. Plasma Assisted Ignition at High Pressures and Low Temperatures. PAI Kinetics and Fast Gas Heating

    Science.gov (United States)

    2014-05-06

    should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of...Combustion 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT SAR 18, NUMBER OF PAGES 97 19a. NAME OF RESPONSIBLE PERSON Gregg... Blin -Simiand N, Jorand F, Postel C 2009 OH kinetic in high-pressure plasmas of atmospheric gases containing C2H6 studied by abso-lute measurement of the

  16. Equilibrium separation in a high pressure helium plasma and its application to the determination of temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Rodero, A.; Garcia, M.C.; Gamero, A. [Universidad de Cordoba (Spain)

    1995-12-31

    The spectroscopy method based on the Boltzmann-plot of emission lines has been usually employed for measuring the excitation temperature (T{sub exc}) in high pressure plasmas. In the present work, it is shown that this method can produce great errors in the temperature determination when equilibrium separation exists. In this way, the suitability of this determination is tested comparing with other alternative methods in a high pressure helium plasma and also studying its separation from the equilibrium situation, via the absolute population measurements of atomic levels and the estimation of its atomic state distribution function (ASDF). We have made this study using a new excitation structure, the axial injection torch (Torche A Injection Axiale or T.I.A.), which produces a high power microwave plasma at atmospheric pressure. The measurements were carried out at the beginning of the flame (the highest line intensity zone) for a 300-900 W power range at 2.45 GHz and 71/min. of helium gas flow.

  17. Atmospheric pressure plasma surface modification of titanium for high temperature adhesive bonding

    NARCIS (Netherlands)

    Akram, M.; Jansen, K.M.B.; Ernst, L.J.; Bhowmik, S.

    2011-01-01

    In this investigation surface treatment of titanium is carried out by plasma ion implantation under atmospheric pressure plasma in order to increase the adhesive bond strength. Prior to the plasma treatment, titanium surfaces were mechanically treated by sand blasting. It is observed that the

  18. Carbon coated nickel nanoparticles produced in high-frequency arc plasma at ambient pressure

    Science.gov (United States)

    Vnukova, Natalia; Dudnik, Alexander; Komogortsev, Sergey; Velikanov, Dmitry; Nemtsev, Ivan; Volochaev, Michael; Osipova, Irina; Churilov, Grigory

    2017-10-01

    The nickel particles with the mean size about 10-20 nm coated with carbon were extracted by the treatment of the carbon condensate with nitric and hydrochloric acids. The initial carbon condensate containing nickel nanoparticles with a graphite conversion was synthesized in the high-frequency carbon-helium arc plasma at ambient pressure with the nickel nanoparticles as a catalyst. The nickel content in the nanoparticles was 84.6 wt%. Magnetic properties of the nanoparticles are characterized by the high hysteresis and thermal stability. The sample of compacted nanoparticles is characterized by electrical resistance much higher than it in of compacted initial condensate.

  19. Rapid inactivation of Penicillium digitatum spores using high-density nonequilibrium atmospheric pressure plasma

    Science.gov (United States)

    Iseki, Sachiko; Ohta, Takayuki; Aomatsu, Akiyoshi; Ito, Masafumi; Kano, Hiroyuki; Higashijima, Yasuhiro; Hori, Masaru

    2010-04-01

    A promising, environmentally safe method for inactivating fungal spores of Penicillium digitatum, a difficult-to-inactivate food spoilage microorganism, was developed using a high-density nonequilibrium atmospheric pressure plasma (NEAPP). The NEAPP employing Ar gas had a high electron density on the order of 1015 cm-3. The spores were successfully and rapidly inactivated using the NEAPP, with a decimal reduction time in spores (D value) of 1.7 min. The contributions of ozone and UV radiation on the inactivation of the spores were evaluated and concluded to be not dominant, which was fundamentally different from the conventional sterilizations.

  20. Plasma-assisted combustion in lean, high-pressure, preheated air-methane mixtures

    Science.gov (United States)

    Sommerer, Timothy; Herbon, John; Saddoughi, Seyed; Deminsky, Maxim; Potapkin, Boris

    2013-09-01

    We combine a simplified physical model with a detailed plasma-chemical reaction mechanism to analyze the use of plasmas to improve flame stability in a gas turbine used for electric power generation. For this application the combustion occurs in a lean mixture of air and methane at high pressure (18.6 atm) and at ``preheat'' temperature 700 K, and the flame zone is both recirculating and turbulent. The system is modeled as a sequence of reactors: a pulsed uniform plasma (Boltzmann), an afterglow region (plug-flow), a flame region (perfectly-stirred), and a downstream region (plug-flow). The plasma-chemical reaction mechanism includes electron-impact on the feedstock species, relaxation in the afterglow to neutral molecules and radicals, and methane combustion chemistry (GRI-Mech 3.0), with extensions to properly describe low-temperature combustion 700-1000 K [M Deminsky et al., Chem Phys 32, 1 (2013)]. We find that plasma treatment of the incoming air-fuel mixture can improve the stability of lean flames, expressed as a reduction in the adiabatic flame temperature at lean blow-out, but that the plasma also generates oxides of nitrogen at the preheat temperature through the reactions e + N2 --> N + N and N + O2 --> NO + O. We find that flame stability is improved with less undesirable NOx formation when the plasma reduced-electric-field E/ N is smaller. A portion of this work was supported by the US Dept of Energy under Award Number DE-FC26-08NT05868.

  1. Piezoresistive Effect in Plasma-Doping of Graphene Sheet for High-Performance Flexible Pressure Sensing Application.

    Science.gov (United States)

    Haniff, M A S M; Hafiz, S M; Huang, N M; Rahman, S A; Wahid, K A A; Syono, M I; Azid, I A

    2017-05-03

    This paper presents a straightforward plasma treatment modification of graphene with an enhanced piezoresistive effect for the realization of a high-performance pressure sensor. The changes in the graphene in terms of its morphology, structure, chemical composition, and electrical properties after the NH3/Ar plasma treatment were investigated in detail. Through a sufficient plasma treatment condition, our studies demonstrated that plasma-treated graphene sheet exhibits a significant increase in sensitivity by one order of magnitude compared to that of the unmodified graphene sheet. The plasma-doping introduced nitrogen (N) atoms inside the graphene structure and was found to play a significant role in enhancing the pressure sensing performance due to the tunneling behavior from the localized defects. The high sensitivity and good robustness demonstrated by the plasma-treated graphene sensor suggest a promising route for simple, low-cost, and ultrahigh resolution flexible sensors.

  2. Apparatus and method for enhanced chemical processing in high pressure and atmospheric plasmas produced by high frequency electromagnetic waves

    Science.gov (United States)

    Efthimion, Philip C.; Helfritch, Dennis J.

    1989-11-28

    An apparatus and method for creating high temperature plasmas for enhanced chemical processing of gaseous fluids, toxic chemicals, and the like, at a wide range of pressures, especially at atmospheric and high pressures includes an electro-magnetic resonator cavity, preferably a reentrant cavity, and a wave guiding structure which connects an electro-magnetic source to the cavity. The cavity includes an intake port and an exhaust port, each having apertures in the conductive walls of the cavity sufficient for the intake of the gaseous fluids and for the discharge of the processed gaseous fluids. The apertures are sufficiently small to prevent the leakage of the electro-magnetic radiation from the cavity. Gaseous fluid flowing from the direction of the electro-magnetic source through the guiding wave structure and into the cavity acts on the plasma to push it away from the guiding wave structure and the electro-magnetic source. The gaseous fluid flow confines the high temperature plasma inside the cavity and allows complete chemical processing of the gaseous fluids at a wide range of pressures.

  3. High-intensity interval training lowers blood pressure and improves apelin and NOx plasma levels in older treated hypertensive individuals.

    Science.gov (United States)

    Izadi, Mohammad Reza; Ghardashi Afousi, Alireza; Asvadi Fard, Maryam; Babaee Bigi, Mohammad Ali

    2018-02-01

    Hypertension is the major risk factor for cardiovascular diseases and is one of the primary causes of morbidity and mortality worldwide. Apelin levels and NO bioavailability are impaired in older hypertensive patients. Exercise is an effective intervention for treating hypertension. Our purpose was to evaluate the effect of high-intensity interval training on blood pressure, apelin, and NOx plasma levels in older treated hypertensive individuals. Thirty treated hypertensive subjects (61.70 ± 5.78 years, 17 males, 13 females) were randomly divided into 6 weeks of high-intensity interval training (n = 15) and control (n = 15). The exercise training was conducted for three 35-min sessions a week (1.5-min interval at 85-90% of heart rate reserve [HRR] and 2 min active phase at 50-55% of HRR). Assessment of plasma apelin, nitrite/nitrate (NOx), and endothelin-1 (ET-1) was performed before and after the intervention. At the end of the study, apelin, and NOx plasma levels increased significantly in the high-intensity interval training (HIIT) group (P = 0.021, P = 0.003, respectively). Conversely, ET-1 plasma levels significantly decreased in the training group after the intervention (P = 0.015). Moreover, there was a positive correlation between the change of plasma apelin and change of plasma NOx (r = 0. 771, P = 0.0008). In addition, there was a negative correlation between the change of plasma ET-1, change of plasma apelin (r = - 0.595, P = 0.019), and variation of NOx (r = - 0.572, P = 0.025). This study indicates that, by increasing of apelin and NOx plasma levels, HIIT may be effective in reducing blood pressure.

  4. Atmospheric pressure plasma jet applications

    Energy Technology Data Exchange (ETDEWEB)

    Park, J.; Herrmann, H.W.; Henins, I.; Selwyn, G.S. [Los Alamos National Lab., NM (United States)

    1998-12-31

    The atmospheric pressure plasma jet (APPJ) is a non-thermal, high pressure plasma discharge that produces a high velocity effluent stream of highly reactive chemical species. The discharge operates on a feedstock gas (e.g., He/O2/H2O) which flows between two concentric cylindrical electrodes: an outer grounded electrode and an inner electrode powered at 13.56 MHz RF. While passing through the plasma, the feedgas becomes excited, ionized or dissociated by electron impact. The fast-flowing effluent consists of ions and electrons, which are rapidly lost by recombination, highly reactive radicals (e.g., O, OH), and metastable species (e.g., O2). The metastable O2, which is reactive to hydrocarbon and other organic species, has been observed through optical emission spectroscopy to decrease by a factor of 2 from the APPJ nozzle exit to a distance of 10 cm. Unreacted metastable O2, and that which does not impinge on a surface, will then decay back to ordinary ground state O2, resulting in a completely dry, environmentally-benign form of surface cleaning. Applications such as removal of photoresist, oxide films and organic residues from wafers for the electronics industry, decontamination of civilian and military areas and personnel exposed to chemical or biological warfare agents, and paint (e.g., graffiti) removal are being considered.

  5. Atmospheric-pressure plasma technology

    Science.gov (United States)

    Kogelschatz, U.

    2004-12-01

    Major industrial plasma processes operating close to atmospheric pressure are discussed. Applications of thermal plasmas include electric arc furnaces and plasma torches for generation of powders, for spraying refractory materials, for cutting and welding and for destruction of hazardous waste. Other applications include miniature circuit breakers and electrical discharge machining. Non-equilibrium cold plasmas at atmospheric pressure are obtained in corona discharges used in electrostatic precipitators and in dielectric-barrier discharges used for generation of ozone, for pollution control and for surface treatment. More recent applications include UV excimer lamps, mercury-free fluorescent lamps and flat plasma displays.

  6. Structural evolution and formation of high-pressure plasmas in X pinches.

    Science.gov (United States)

    Chittenden, J P; Ciardi, A; Jennings, C A; Lebedev, S V; Hammer, D A; Pikuz, S A; Shelkovenko, T A

    2007-01-12

    Two- and three-dimensional MHD simulations are used to provide a theoretical description of 2 wire molybdenum X-pinch experiments. The initial evolution from solid wires to the formation of supersonic jets and a central micro-Z pinch is found to result from the slow rate of wire ablation and from the distribution of the Lorentz force. The growth of m=0 instabilities triggers the formation of micron sized regions of intense x-ray emission with plasma pressures in the Gbar range. A simple analytical model is used to predict how the maximum density and temperature scale with material and current.

  7. Plasma-chemical reactions: low pressure acetylene plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Benedikt, J [Faculty for Physics and Astronomy, Research Group Reactive Plasmas, Ruhr-Universitaet Bochum, Universitaetsstr. 150, 44780 Bochum (Germany)

    2010-02-03

    Reactive plasmas are a well-known tool for material synthesis and surface modification. They offer a unique combination of non-equilibrium electron and ion driven plasma chemistry, energetic ions accelerated in the plasma sheath at the plasma-surface interface, high fluxes of reactive species towards surfaces and a friendly environment for thermolabile objects. Additionally, small negatively charged clusters can be generated, because they are confined in the positive plasma potential. Plasmas in hydrocarbon gases, and especially in acetylene, are a good example for the discussion of different plasma-chemical processes. These plasmas are involved in a plethora of possible applications ranging from fuel conversion to formation of single wall carbon nanotubes. This paper provides a concise overview of plasma-chemical reactions (PCRs) in low pressure reactive plasmas and discusses possible experimental and theoretical methods for the investigation of their plasma chemistry. An up-to-date summary of the knowledge about low pressure acetylene plasmas is given and two particular examples are discussed in detail: (a) Ar/C{sub 2}H{sub 2} expanding thermal plasmas with electron temperatures below 0.3 eV and with a plasma chemistry initiated by charge transfer reactions and (b) radio frequency C{sub 2}H{sub 2} plasmas, in which the energetic electrons mainly control PCRs. (topical review)

  8. Evidence for plasma phase transition in high pressure hydrogen from ab-initio simulations

    Energy Technology Data Exchange (ETDEWEB)

    Morales, M; Pierleoni, C; Schwegler, E; Ceperley, D

    2010-02-08

    We have performed a detailed study of molecular dissociation in liquid hydrogen using both Born-Oppenheimer molecular dynamics with Density Functional Theory and Coupled Electron-Ion Monte Carlo simulations. We observe a range of densities where (dP/d{rho}){sub T} = 0 that coincides with sharp discontinuities in the electronic conductivity, which is clear evidence of the plasma phase transition for temperatures 600K {le} T {le} 1500K. Both levels of theory exhibit the transition, although Quantum Monte Carlo predicts higher transition pressures. Based on the temperature dependence of the discontinuity in the electronic conductivity, we estimate the critical point of the transition at temperatures slightly below 2000 K. We examine the influence of proton zero point motion by using Path Integral Molecular Dynamics with Density Functional Theory; the main effect is to shift the transition to lower pressures. Furthermore, we calculate the melting curve of molecular hydrogen up to pressures of 200 GPa, finding a reentrant melting line in good agreement with previous calculations. The melting line crosses the metalization line at 700 K and 220 GPa using density functional energetics and at 550 K and 290 GPa using Quantum Monte Carlo energetics.

  9. Development mechanism of high pressure argon plasma produced by irradiation of excimer laser. Ekishima reza ni yori seiseishita koatsuryoku arugon purazuma no seicho kiko

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, J.; Tsuda, N.; Uchida, Y.; Furuhashi, H. (Aichi Inst. of Technology, Aichi (Japan)); Sahashi, T. (Daido Inst. of Technology, Aichi (Japan))

    1994-04-20

    The studies of a high temperature and high density laser plasma are being carried out centering around solid targets, but a high density plasma can be generated also by focused irradiation of a laser light onto a high pressure gas target. However, in this case, studies on a high pressure laser plasma using the ultra-violet beam are seldom conducted. In this paper, the generation mechanism of a plasma generated mainly behind the focal point of the lens is mentioned in case when the ultra violet laser beam is focused and irradiated onto a high pressure argon gas, and it has been compared for study with the plasma generated by a ruby laser. Part of the obtained results is as follows; it has been elucidated that the plasma generated behind the focal point by focusing and irradiating an ultra violet laser beam onto a high pressure argon gas is growing simultaneously by the radiation supported shock wave and the breakdown wave, same as the case of a visible laser beam. When the ultra violet beam with frequency higher than the plasma frequency is irradiated, a plasma grows in front of the focal point too. 6 refs., 9 figs.

  10. Rosetta and Mars Express observations of the influence of high solar wind pressure on the Martian plasma environment

    Directory of Open Access Journals (Sweden)

    N. J. T. Edberg

    2009-12-01

    Full Text Available We report on new simultaneous in-situ observations at Mars from Rosetta and Mars Express (MEX on how the Martian plasma environment is affected by high pressure solar wind. A significant sharp increase in solar wind density, magnetic field strength and turbulence followed by a gradual increase in solar wind velocity is observed during ~24 h in the combined data set from both spacecraft after Rosetta's closest approach to Mars on 25 February 2007. The bow shock and magnetic pileup boundary are coincidently observed by MEX to become asymmetric in their shapes. The fortunate orbit of MEX at this time allows a study of the inbound boundary crossings on one side of the planet and the outbound crossings on almost the opposite side, both very close to the terminator plane. The solar wind and interplanetary magnetic field (IMF downstream of Mars are monitored through simultaneous measurements provided by Rosetta. Possible explanations for the asymmetries are discussed, such as crustal magnetic fields and IMF direction. In the same interval, during the high solar wind pressure pulse, MEX observations show an increased amount of escaping planetary ions from the polar region of Mars. We link the high pressure solar wind with the observed simultaneous ion outflow and discuss how the pressure pulse could also be associated with the observed boundary shape asymmetry.

  11. Rosetta and Mars Express observations of the influence of high solar wind pressure on the Martian plasma environment

    Directory of Open Access Journals (Sweden)

    N. J. T. Edberg

    2009-12-01

    Full Text Available We report on new simultaneous in-situ observations at Mars from Rosetta and Mars Express (MEX on how the Martian plasma environment is affected by high pressure solar wind. A significant sharp increase in solar wind density, magnetic field strength and turbulence followed by a gradual increase in solar wind velocity is observed during ~24 h in the combined data set from both spacecraft after Rosetta's closest approach to Mars on 25 February 2007. The bow shock and magnetic pileup boundary are coincidently observed by MEX to become asymmetric in their shapes. The fortunate orbit of MEX at this time allows a study of the inbound boundary crossings on one side of the planet and the outbound crossings on almost the opposite side, both very close to the terminator plane. The solar wind and interplanetary magnetic field (IMF downstream of Mars are monitored through simultaneous measurements provided by Rosetta. Possible explanations for the asymmetries are discussed, such as crustal magnetic fields and IMF direction. In the same interval, during the high solar wind pressure pulse, MEX observations show an increased amount of escaping planetary ions from the polar region of Mars. We link the high pressure solar wind with the observed simultaneous ion outflow and discuss how the pressure pulse could also be associated with the observed boundary shape asymmetry.

  12. Evaluation of a pilot scale high pressure plasma ozonizer for use in ...

    African Journals Online (AJOL)

    The plasma technique which is used for wastewater treatment is one of the most effective processes for ozone production. In this study, a laboratory scale plasma technique ozonizer designed for treating wastewater was tested under various operation conditions which included voltage (E), current frequency (f), electrical ...

  13. Pressure Fluctuations in Nonideal Plasma

    NARCIS (Netherlands)

    Lankin, A.; Norman, G.; Saitov, I.

    Fluctuations of pressure of singly ionized nonideal plasma are studied using the fluctuation approach which provides the self-consistent joint description of free and weakly bound electron states. The classical molecular dynamics method is used. The electron-ion interaction is described by the

  14. Access to a New Plasma Edge State with High Density and Pressures using Quiescent H-mode

    Energy Technology Data Exchange (ETDEWEB)

    Solomon, Wayne M. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Snyder, P. B. [General Atomics, San Diego, CA (United States); Burrell, K. H. [General Atomics, San Diego, CA (United States); Fenstermacher, M. E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Garofalo, A. M. [General Atomics, San Diego, CA (United States); Grierson, B. A. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Loarte, A. [ITER Organization, St. Paul Lez Durance (France); McKee, G. R. [Univ. of Wisconsin, Madison, WI (United States); Nazikian, R [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Osborne, T. H. [General Atomics, San Diego, CA (United States)

    2014-07-01

    A path to a new high performance regime has been discovered in tokamaks that could improve the attractiveness of a fusion reactor. Experiments on DIII-D using a quiescent H-mode edge have navigated a valley of improved edge peeling-ballooning stability that opens up with strong plasma shaping at high density, leading to a doubling of the edge pressure over standard edge localized mode (ELM)ing H-mode at these parameters. The thermal energy confinement time increases both as a result of the increased pedestal height and improvements in the core transport and reduced low-k turbulence. Calculations of the pedestal height and width as a function of density using constraints imposed by peeling-ballooning and kinetic-ballooning theory are in quantitative agreement with the measurements.

  15. Phenomenology of plasma engine cathodes at high current rates and low pressures

    Science.gov (United States)

    Huegel, H.; Kruelle, G.

    1984-01-01

    The effects of low surrounding pressures on cathodes of arc jet engines with electromagnetic acceleration are investigated for pressure and current energies of 20 to 100 Torr. and 400 to 1000 A. Experiments with 50 mm long and 8 mm diameter tungsten-thorium cathode in a coaxial gas flow show that pre-heating of the cathode reduces the duration of the instable arc discharge and thus material loss. The use of lighter gases also reduces instability effects, as well as the use of increased pressures and a massive gas influx.

  16. On the plasma confinement by acoustic resonance. An innovation for electrodeless high-pressure discharge lamps

    Science.gov (United States)

    Courret, Gilles; Nikkola, Petri; Wasterlain, Sébastien; Gudozhnik, Olexandr; Girardin, Michel; Braun, Jonathan; Gavin, Serge; Croci, Mirko; Egolf, Peter W.

    2017-08-01

    In an applied research project on the development of a pulsed microwave sulfur lamp prototype of 1 kW, we have discovered an amazing phenomenon in which the plasma forms a ball staying at the center of the bulb despite gravity, thus protecting the glass from melting. In this paper, it is shown that this results from an acoustic resonance in a spherical mode. Measurements of the plasma response to short pulses are presented showing beats at the spherical resonance. It is demonstrated that the beats could result from the simultaneous excitation of two normal modes with a frequency difference of approximately 1%. One of the two frequencies matches precisely the microwave pulses repetition, a little below 30 kHz. Thus this one is due to a forced oscillation, whereas the other one is due to a free oscillation. The phase velocity of sound was calculated as a function of temperature in order to find the series of temperatures at which a resonance would occur if the bulb were an isothermal solid sphere. The mean temperature inside the actual bulb was determined from the only doublet of this series, that has characteristic frequencies close enough to cause the observed beats. In addition, one of these two modes has a spherical symmetry that can explain the plasma ball formation. The obtained mean temperature is consistent with the direct measurements on the bulb surface as well as with the temperature in the core of a similar plasma found in the literature. We have also proposed a model of the resonance onset based on the acoustic dispersion and the sound amplification due to electromagnetic coupling.

  17. High Blood Pressure (Hypertension)

    Science.gov (United States)

    ... Print Page Text Size: A A A Listen High Blood Pressure (Hypertension) Nearly 1 in 3 American adults has high ... weight. How Will I Know if I Have High Blood Pressure? High blood pressure is a silent problem — you ...

  18. Low Temperature Atmospheric Pressure Plasma Sterilization Shower

    Science.gov (United States)

    Gandhiraman, R. P.; Beeler, D.; Meyyappan, M.; Khare, B. N.

    2012-10-01

    Low-temperature atmospheric pressure plasma sterilization shower to address both forward and backward biological contamination issues is presented. The molecular effects of plasma exposure required to sterilize microorganisms is also analysed.

  19. Hypertension (High Blood Pressure)

    Science.gov (United States)

    ... Situations Talking to Your Parents - or Other Adults Hypertension (High Blood Pressure) KidsHealth > For Teens > Hypertension (High Blood Pressure) Print ... rest temperature diet emotions posture medicines Why Is High Blood Pressure Bad? High blood pressure means a person's heart ...

  20. High Blood Pressure (Hypertension)

    Science.gov (United States)

    ... other risk factors, like diabetes, you may need treatment. How does high blood pressure affect pregnant women? A few women will get high blood pressure when they are pregnant. When pregnant women get high blood pressure, it is called preeclampsia or toxemia. How do I control my high ...

  1. DC superimposed AC high voltage: A new strategy for transferring stable He atmospheric pressure cold plasma bullets through long dielectric tubes

    Science.gov (United States)

    Siadati, S. N.; Sohbatzadeh, F.; Valinataj Omran, Azadeh

    2017-06-01

    This study developed a stable transfer of He atmospheric pressure cold plasma bullets in a large dielectric tube with a length of 70 cm and an inner diameter of 0.4-1.6 cm. DC superimposed AC voltage was used for this purpose. The DC component of the applied voltage generated corona ionization through the tube, which helped in the ignition and transfer of the plasma as a pre-ionization background. The bullets followed the frequency of the AC component; therefore, very high applied energy was not required to ignite this large-scale plasma. To our knowledge, this is the first time such a complex waveform has been reported for the transfer of a plasma bullet. The characteristics of the transferring plasma bullet, such as the power, charge, propagation speed, resistance, AC electrical field (EF) of the plasma, and electrostatic field on the tube surface, were measured. The influence of the tube diameter on these characteristics was investigated. The results showed that the power applied, charge, and power deposited on the target increased as the tube diameter increased. Less plasma resistance and radiation were observed using larger diameters. The root mean square (RMS) values of the axial AC EF of the bullet along the jet axis were higher for the larger diameters, but no special relation between the propagation speed, radial AC EF, and static surface field and tube diameter was observed.

  2. Preventing High Blood Pressure

    Science.gov (United States)

    ... Heart Disease Cholesterol Salt Million Hearts® WISEWOMAN Preventing High Blood Pressure: Healthy Living Habits Recommend on Facebook Tweet Share ... meal and snack options can help you avoid high blood pressure and its complications. Be sure to eat plenty ...

  3. High blood pressure - children

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007696.htm High blood pressure - children To use the sharing features on this page, please enable JavaScript. High blood pressure (hypertension) is an increase in the force of ...

  4. High blood pressure - infants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007329.htm High blood pressure - infants To use the sharing features on this page, please enable JavaScript. High blood pressure (hypertension) is an increase in the force of ...

  5. High blood pressure medications

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007484.htm High blood pressure medicines To use the sharing features on this page, please enable JavaScript. Treating high blood pressure will help prevent problems such as heart disease, ...

  6. High Blood Pressure (Hypertension)

    Science.gov (United States)

    ... two types of high blood pressure. Primary (essential) hypertension For most adults, there's no identifiable cause of ... tends to develop gradually over many years. Secondary hypertension Some people have high blood pressure caused by ...

  7. Biomedical applications and diagnostics of atmospheric pressure plasma

    Science.gov (United States)

    Petrović, Z. Lj; Puač, N.; Lazović, S.; Maletić, D.; Spasić, K.; Malović, G.

    2012-03-01

    Numerous applications of non-equilibrium (cold, low temperature) plasmas require those plasmas to operate at atmospheric pressure. Achieving non-equilibrium at atmospheric pressure is difficult since the ionization growth is very fast at such a high pressure. High degree of ionization on the other hand enables transfer of energy between electrons and ions and further heating of the background neutral gas through collisions between ions and neutrals. Thus, all schemes to produce non-equilibrium plasmas revolve around some form of control of ionization growth. Diagnostics of atmospheric pressure plasmas is difficult and some of the techniques cannot be employed at all. The difficulties stem mostly from the small size. Optical emission spectroscopy and laser absorption spectroscopy require very high resolution in order to resolve the anatomy of the discharges. Mass analysis is not normally applicable for atmospheric pressure plasmas, but recently systems with triple differential pumping have been developed that allow analysis of plasma chemistry at atmospheric pressures which is essential for numerous applications. Application of such systems is, however, not free from problems. Applications in biomedicine require minimum heating of the ambient air. The gas temperature should not exceed 40 °C to avoid thermal damage to the living tissues. Thus, plasmas should operate at very low powers and power control is essential. We developed unique derivative probes that allow control of power well below 1 W and studied four different sources, including dielectric barrier discharges, plasma needle, atmospheric pressure jet and micro atmospheric pressure jet. The jet operates in plasma bullet regime if proper conditions are met. Finally, we cover results on treatment of bacteria and human cells as well as treatment of plants by plasmas. Localized delivery of active species by plasmas may lead to a number of medical procedures that may also involve removal of bacteria, fungi and

  8. Tunable high pressure lasers

    Science.gov (United States)

    Hess, R. V.

    1976-01-01

    Atmospheric transmission of high energy CO2 lasers is considerably improved by high pressure operation which, due to pressure broadening, permits tuning the laser lines off atmospheric absorption lines. Pronounced improvement is shown for horizontal transmission at altitudes above several kilometers and for vertical transmission through the entire atmosphere. Applications of tunable high pressure CO2 lasers to energy transmission and to remote sensing are discussed along with initial efforts in tuning high pressure CO2 lasers.

  9. High-pressure microbiology

    National Research Council Canada - National Science Library

    Michiels, Chris; Bartlett, Douglas Hoyt; Aertsen, Abram

    2008-01-01

    ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1. High Hydrostatic Pressure Effects in the Biosphere: from Molecules to Microbiology * Filip Meersman and Karel Heremans . . . . . . . . . . . . 2. Effects...

  10. High Blood Pressure Facts

    Science.gov (United States)

    ... Stroke Heart Disease Cholesterol Salt Million Hearts® WISEWOMAN High Blood Pressure Facts Recommend on Facebook Tweet Share Compartir On ... the facts about high blood pressure [PDF-255K] . High Blood Pressure in the United States About 75 million American ...

  11. MicroScale - Atmospheric Pressure Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Sankaran, Mohan [Case Western Reserve University

    2012-01-25

    Low-temperature plasmas play an essential role in the manufacturing of integrated circuits which are ubiquitous in modern society. In recent years, these top-down approaches to materials processing have reached a physical limit. As a result, alternative approaches to materials processing are being developed that will allow the fabrication of nanoscale materials from the bottom up. The aim of our research is to develop a new class of plasmas, termed “microplasmas” for nanomaterials synthesis. Microplasmas are a special class of plasmas formed in geometries where at least one dimension is less than 1 mm. Plasma confinement leads to several unique properties including high-pressure stability and non-equilibrium that make microplasams suitable for nanomaterials synthesis. Vapor-phase precursors can be dissociated to homogeneously nucleate nanometer-sized metal and alloyed nanoparticles. Alternatively, metal salts dispersed in liquids or polymer films can be electrochemically reduced to form metal nanoparticles. In this talk, I will discuss these topics in detail, highlighting the advantages of microplasma-based systems for the synthesis of well-defined nanomaterials.

  12. Plasma density enhancement in atmospheric-pressure dielectric-barrier discharges by high-voltage nanosecond pulse in the pulse-on period: a PIC simulation

    Science.gov (United States)

    Sang, Chaofeng; Sun, Jizhong; Wang, Dezhen

    2010-02-01

    A particle-in-cell (PIC) plus Monte Carlo collision simulation is employed to investigate how a sustainable atmospheric pressure single dielectric-barrier discharge responds to a high-voltage nanosecond pulse (HVNP) further applied to the metal electrode. The results show that the HVNP can significantly increase the plasma density in the pulse-on period. The ion-induced secondary electrons can give rise to avalanche ionization in the positive sheath, which widens the discharge region and enhances the plasma density drastically. However, the plasma density stops increasing as the applied pulse lasts over certain time; therefore, lengthening the pulse duration alone cannot improve the discharge efficiency further. Physical reasons for these phenomena are then discussed.

  13. Blood pressure and plasma catecholamines in acute and prolonged hypoxia

    DEFF Research Database (Denmark)

    Kanstrup, I L; Poulsen, T D; Hansen, J M

    1999-01-01

    and 5 days after rapid, passive transport to high altitude (4,559 m). Acute mountain sickness scores ranged from 5 to 16 (maximal attainable score: 20) on the first day but were reduced to 0-8 by the fifth day. Systolic blood pressure, heart rate, and plasma epinephrine increased on day 1 at altitude...... compared with sea level but declined again on day 5, whereas diastolic and mean blood pressures continued to rise in parallel with plasma norepinephrine. With local cooling, an increased vasoactive response was seen on the fifth day at altitude. Very high pressures were obtained, and the pressure elevation...

  14. Ultrasound enhanced plasma surface modification at atmospheric pressure

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Singh, Shailendra Vikram; Norrman, Kion

    2012-01-01

    Efficiency of atmospheric pressure plasma treatment can be highly enhanced by simultaneous high power ultrasonic irradiation onto the treating surface. It is because ultrasonic waves with a sound pressure level (SPL) above ∼140 dB can reduce the thickness of a boundary gas layer between the plasm...

  15. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... blood, which leads to secondary high blood pressure. Risk Factors Anyone can develop high blood pressure; however, ... history of high blood pressure can increase your risk for developing high blood pressure. Age Blood pressure ...

  16. Surface passivation of c-Si for silicon heterojunction solar cells using high-pressure hydrogen diluted plasmas

    Directory of Open Access Journals (Sweden)

    Dimitrios Deligiannis

    2015-09-01

    Full Text Available In this work we demonstrate excellent c-Si surface passivation by depositing a-Si:H in the high-pressure and high hydrogen dilution regime. By using high hydrogen dilution of the precursor gases during deposition the hydrogen content of the layers is sufficiently increased, while the void fraction is reduced, resulting in dense material. Results show a strong dependence of the lifetime on the substrate temperature and a weaker dependence on the hydrogen dilution. After applying a post-deposition annealing step on the samples equilibration of the lifetime occurs independent of the initial nanostructure.

  17. On the Experimental and Theoretical Investigations of Lean Partially Premixed Combustion, Burning Speed, Flame Instability and Plasma Formation of Alternative Fuels at High Temperatures and Pressures

    Science.gov (United States)

    Askari, Omid

    This dissertation investigates the combustion and injection fundamental characteristics of different alternative fuels both experimentally and theoretically. The subjects such as lean partially premixed combustion of methane/hydrogen/air/diluent, methane high pressure direct-injection, thermal plasma formation, thermodynamic properties of hydrocarbon/air mixtures at high temperatures, laminar flames and flame morphology of synthetic gas (syngas) and Gas-to-Liquid (GTL) fuels were extensively studied in this work. These subjects will be summarized in three following paragraphs. The fundamentals of spray and partially premixed combustion characteristics of directly injected methane in a constant volume combustion chamber have been experimentally studied. The injected fuel jet generates turbulence in the vessel and forms a turbulent heterogeneous fuel-air mixture in the vessel, similar to that in a Compressed Natural Gas (CNG) Direct-Injection (DI) engines. The effect of different characteristics parameters such as spark delay time, stratification ratio, turbulence intensity, fuel injection pressure, chamber pressure, chamber temperature, Exhaust Gas recirculation (EGR) addition, hydrogen addition and equivalence ratio on flame propagation and emission concentrations were analyzed. As a part of this work and for the purpose of control and calibration of high pressure injector, spray development and characteristics including spray tip penetration, spray cone angle and overall equivalence ratio were evaluated under a wide range of fuel injection pressures of 30 to 90 atm and different chamber pressures of 1 to 5 atm. Thermodynamic properties of hydrocarbon/air plasma mixtures at ultra-high temperatures must be precisely calculated due to important influence on the flame kernel formation and propagation in combusting flows and spark discharge applications. A new algorithm based on the statistical thermodynamics was developed to calculate the ultra-high temperature plasma

  18. Charge dependence of the plasma travel length in atmospheric-pressure plasma

    Energy Technology Data Exchange (ETDEWEB)

    Yambe, Kiyoyuki; Konda, Kohmei; Masuda, Seiya [Graduate School of Science and Technology, Niigata University, Niigata 950-2181 (Japan)

    2016-06-15

    Plasma plume is generated using a quartz tube, helium gas, and foil electrode by applying AC high voltage under the atmosphere. The plasma plume is released into the atmosphere from inside of the quartz tube and is seen as the continuous movement of the plasma bullet. The travel length of plasma bullet is defined from plasma energy and force due to electric field. The drift velocity of plasma bullet has the upper limit under atmospheric-pressure because the drift velocity is determined from the balance between electric field and resistive force due to collisions between plasma and air. The plasma plume charge depends on the drift velocity. Consequently, in the laminar flow of helium gas flow state, the travel length of the plasma plume logarithmically depends on the plasma plume charge which changes with both the electric field and the resistive force.

  19. Effects of total dietary polyphenols on plasma nitric oxide and blood pressure in a high cardiovascular risk cohort. The PREDIMED randomized trial.

    Science.gov (United States)

    Medina-Remón, A; Tresserra-Rimbau, A; Pons, A; Tur, J A; Martorell, M; Ros, E; Buil-Cosiales, P; Sacanella, E; Covas, M I; Corella, D; Salas-Salvadó, J; Gómez-Gracia, E; Ruiz-Gutiérrez, V; Ortega-Calvo, M; García-Valdueza, M; Arós, F; Saez, G T; Serra-Majem, L; Pinto, X; Vinyoles, E; Estruch, R; Lamuela-Raventos, R M

    2015-01-01

    Hypertension is one of the main cardiovascular risk factors in the elderly. The aims of this work were to evaluate if a one-year intervention with two Mediterranean diets (Med-diet) could decrease blood pressure (BP) due to a high polyphenol consumption, and if the decrease in BP was mediated by plasma nitric oxide (NO) production. An intervention substudy of 200 participants at high cardiovascular risk was carried out within the PREDIMED trial. They were randomly assigned to a low-fat control diet or to two Med-diets, one supplemented with extra virgin olive oil (Med-EVOO) and the other with nuts (Med-nuts). Anthropometrics and clinical parameters were measured at baseline and after one year of intervention, as well as BP, plasma NO and total polyphenol excretion (TPE) in urine samples. Systolic and diastolic BP decreased significantly after a one-year dietary intervention with Med-EVOO and Med-nuts. These changes were associated with a significant increase in TPE and plasma NO. Additionally, a significant positive correlation was observed between changes in urinary TPE, a biomarker of TP intake, and in plasma NO (Beta = 4.84; 95% CI: 0.57-9.10). TPE in spot urine sample was positively correlated with plasma NO in Med-diets supplemented with either EVOO or nuts. The statistically significant increases in plasma NO were associated with a reduction in systolic and diastolic BP levels, adding to the growing evidence that polyphenols might protect the cardiovascular system by improving the endothelial function and enhancing endothelial synthesis of NO. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Plasma detachment study of high density helium plasmas in the Pilot-PSI device

    NARCIS (Netherlands)

    Hayashi, Y.; Jesko, K.; van der Meiden, H. J.; Vernimmen, J. W. M.; Morgan, T. W.; Ohno, N.; Kajita, S.; Yoshikawa, M.; Masuzaki, S.

    2016-01-01

    We have investigated plasma detachment phenomena of high-density helium plasmas in the linear plasma device Pilot-PSI, which can realize a relevant ITER SOL/Divertor plasma condition. The experiment clearly indicated plasma detachment features such as drops in the plasma pressure and particle flux

  1. Modeling of low pressure plasma sources for microelectronics fabrication

    Science.gov (United States)

    Agarwal, Ankur; Bera, Kallol; Kenney, Jason; Likhanskii, Alexandre; Rauf, Shahid

    2017-10-01

    Chemically reactive plasmas operating in the 1 mTorr-10 Torr pressure range are widely used for thin film processing in the semiconductor industry. Plasma modeling has come to play an important role in the design of these plasma processing systems. A number of 3-dimensional (3D) fluid and hybrid plasma modeling examples are used to illustrate the role of computational investigations in design of plasma processing hardware for applications such as ion implantation, deposition, and etching. A model for a rectangular inductively coupled plasma (ICP) source is described, which is employed as an ion source for ion implantation. It is shown that gas pressure strongly influences ion flux uniformity, which is determined by the balance between the location of plasma production and diffusion. The effect of chamber dimensions on plasma uniformity in a rectangular capacitively coupled plasma (CCP) is examined using an electromagnetic plasma model. Due to high pressure and small gap in this system, plasma uniformity is found to be primarily determined by the electric field profile in the sheath/pre-sheath region. A 3D model is utilized to investigate the confinement properties of a mesh in a cylindrical CCP. Results highlight the role of hole topology and size on the formation of localized hot-spots. A 3D electromagnetic plasma model for a cylindrical ICP is used to study inductive versus capacitive power coupling and how placement of ground return wires influences it. Finally, a 3D hybrid plasma model for an electron beam generated magnetized plasma is used to understand the role of reactor geometry on plasma uniformity in the presence of E  ×  B drift.

  2. On equilibria of finite pressure plasma in magnetic multipoles

    Energy Technology Data Exchange (ETDEWEB)

    Krasheninnikov, S. I.; Soboleva, T. K.

    2001-07-01

    Separable solutions of finite plasma pressure equilibrium in a point multipole are found. Using the energy principle it is demonstrated that these solutions are interchange stable for quadripole and sextipole configurations. The low and high pressure forms of the solution in sextipole configuration are explicitly displayed.

  3. Unexpected high plasma cobalamin

    DEFF Research Database (Denmark)

    Arendt, Johan F B; Nexo, Ebba

    2013-01-01

    It is well-established that more than 8% of patients examined for vitamin B12 deficiency unexpectedly have increased plasma levels of the vitamin, but so far there are no guidelines for the clinical interpretation of such findings. In this review, we summarise known associations between high plasma...... cobalamin binding proteins, transcobalamin and haptocorrin. Based on current knowledge, we suggest a strategy for the clinical interpretation of unexpected high plasma cobalamin. Since a number of the associated diseases are critical and life-threatening, the strategy promotes the concept of 'think...

  4. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Back To Health Topics / High Blood Pressure High Blood Pressure Also known as Hypertension Leer en español ... vessels (arteries) at higher than normal pressures. Measuring Blood Pressure Blood pressure is the force of blood ...

  5. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... To Health Topics / High Blood Pressure High Blood Pressure Also known as Hypertension See also Information for ... arteries) at higher than normal pressures. Measuring Blood Pressure Blood pressure is the force of blood pushing ...

  6. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Back To Health Topics / High Blood Pressure High Blood Pressure Also known as Hypertension See also Information ... vessels (arteries) at higher than normal pressures. Measuring Blood Pressure Blood pressure is the force of blood ...

  7. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Back To Health Topics / High Blood Pressure High Blood Pressure Also known as Hypertension See also Information for ... vessels (arteries) at higher than normal pressures. Measuring Blood Pressure Blood pressure is the force of blood pushing ...

  8. A rapid, sensitive and validated method for the determination of ondansetron in human plasma by reversed-phase high-pressure liquid chromatography.

    Science.gov (United States)

    Chandrasekar, Durairaj; Ramakrishna, Sistla; Diwan, Prakash V

    2004-01-01

    A simple and sensitive method for the determination of ondansetron (CAS 116002-70-1) in human plasma was developed using high-pressure liquid chromatography (HPLC). The procedure involves extraction of human plasma with tertiary butyl methyl ether containing 2 mol/l sodium hydroxide, followed by reversed-phase HPLC using a LiChrospher 100 RP-18e 5 microm column and UV detection at 305 nm. The retention times of ondansetron and internal standard (propranolol hydrochloride, CAS 318-98-9) were 9.38 and 13.40 min, respectively. The calibration curves were linear over the range of 10 ng/ml (lower limit of quantitation, LOQ) and 380 ng/ml for ondansetron. The intra- and inter-assay coefficients of variation for all the criteria of validation were less than 15% over the linearity range. Ondansetron was stable upon storage in human plasma. The sensitivity and precision of the method were within the accepted limits (< 15 %) throughout the validation period. The present method is useful for determination of plasma concentrations of ondansetron during human pharmacokinetic studies.

  9. Feasibility of generating a useful laser-induced breakdown spectroscopy plasma on rocks at high pressure: preliminary study for a Venus mission

    Energy Technology Data Exchange (ETDEWEB)

    Arp, Zane A.; Cremers, David A. E-mail: cremers_david@lanl.gov; Harris, Ronny D.; Oschwald, David M.; Parker, Gary R.; Wayne, David M

    2004-07-30

    Laser-induced breakdown spectroscopy (LIBS) is being developed for future use on landers and rovers to Mars. The method also has potential for use on probes to other planets, the Moon, asteroids and comets. Like Mars, Venus is of strong interest because of its proximity to earth, but unlike Mars, conditions at the surface are far more hostile with temperatures in excess of 700 K and pressures on the order of 9.1 MPa (90 atm). These conditions present a significant challenge to spacecraft design and demand that rapid methods of chemical data gathering be implemented. The advantages of LIBS (e.g. stand-off and very rapid analysis) make the method particularly attractive for Venus exploration because of the expected short operational lifetimes ({approx}2 h) of surface instrumentation. Although the high temperature of Venus should pose no problem to the analytical capabilities of the LIBS spark, the demonstrated strong dependence of laser plasma characteristics on ambient gas pressures below earth atmospheric pressure requires that LIBS measurements be evaluated at the high Venus surface pressures. Here, we present a preliminary investigation of LIBS at 9.1 MPa for application to the analysis of a basalt rock sample. The results suggest the feasibility of the method for a Venus surface probe and that further study is justified.

  10. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... those used to diagnose high blood pressure, prehypertension can progress to high blood pressure and should be ... pressure weakens and damages your blood vessels, which can lead to complications . Types of High Blood Pressure ...

  11. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... the development of high blood pressure later in life. Environmental Causes of High Blood Pressure Environmental causes ... Tend to get high blood pressure earlier in life. Often, on average, have higher blood pressure numbers. ...

  12. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... and large arteries, which can affect blood pressure. Genetic Causes of High Blood Pressure Much of the ... involved in high blood pressure has come from genetic studies. High blood pressure often runs in families. ...

  13. High-pressure microfluidics

    Science.gov (United States)

    Hjort, K.

    2015-03-01

    When using appropriate materials and microfabrication techniques, with the small dimensions the mechanical stability of microstructured devices allows for processes at high pressures without loss in safety. The largest area of applications has been demonstrated in green chemistry and bioprocesses, where extraction, synthesis and analyses often excel at high densities and high temperatures. This is accessible through high pressures. Capillary chemistry has been used since long but, just like in low-pressure applications, there are several potential advantages in using microfluidic platforms, e.g., planar isothermal set-ups, large local variations in geometries, dense form factors, small dead volumes and precisely positioned microstructures for control of reactions, catalysis, mixing and separation. Other potential applications are in, e.g., microhydraulics, exploration, gas driven vehicles, and high-pressure science. From a review of the state-of-art and frontiers of high pressure microfluidics, the focus will be on different solutions demonstrated for microfluidic handling at high pressures and challenges that remain.

  14. An ultra-high pressure liquid chromatography-tandem mass spectrometry method for the quantification of teicoplanin in plasma of neonates.

    Science.gov (United States)

    Begou, O; Kontou, A; Raikos, N; Sarafidis, K; Roilides, E; Papadoyannis, I N; Gika, H G

    2017-03-15

    The development and validation of an ultra-high pressure liquid chromatography (UHPLC) tandem mass spectrometry (MS/MS) method was performed with the aim to be applied for the quantification of plasma teicoplanin concentrations in neonates. Pharmacokinetic data of teicoplanin in the neonatal population is very limited, therefore, a sensitive and reliable method for the determination of all isoforms of teicoplanin applied in a low volume of sample is of real importance. Teicoplanin main components were extracted by a simple acetonitrile precipitation step and analysed on a C18 chromatographic column by a triple quadrupole MS with electrospray ionization. The method provides quantitative data over a linear range of 25-6400ng/mL with LOD 8.5ng/mL and LOQ 25ng/mL for total teicoplanin. The method was applied in plasma samples from neonates to support pharmacokinetic data and proved to be a reliable and fast method for the quantification of teicoplanin concentration levels in plasma of infants during therapy in Intensive Care Unit. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... complications. Preventing High Blood Pressure Onset Healthy lifestyle habits can help prevent high blood pressure from developing. It is important to check your blood pressure regularly. Children should have their blood pressure checked starting at ...

  16. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... can help you track your blood pressure. Pregnancy Planning High blood pressure can cause problems for mother ... View all news on High Blood Pressure RELATED EVENT The Role of Microbiota in Blood Pressure Regulation ...

  17. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... blood pressure and should be taken seriously. Over time, consistently high blood pressure weakens and damages your ... Blood Pressure When blood pressure stays high over time, it can damage the body and cause complications. ...

  18. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Card can help you track your blood pressure. Pregnancy Planning High blood pressure can cause problems for ... control your blood pressure before and during the pregnancy. Some women develop high blood pressure during pregnancy. ...

  19. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... or its complications. Preventing High Blood Pressure Onset Healthy lifestyle habits can help prevent high blood pressure from developing. It is important to check your blood pressure regularly. Children should have their blood pressure checked starting at ...

  20. Superconductivity under high pressure

    Energy Technology Data Exchange (ETDEWEB)

    Amaya, K.; Shimizu, K.; Takeda, K.; Tateiwa, N.; Muramatsu, T.; Ishizuka, M.; Kobayashi, T.C

    2003-05-01

    In part 1, we review techniques developed in our laboratory for producing the complex extreme condition of very low temperature and ultra-high pressure and those for measuring electrical resistance and magnetization of the sample confined in the extremely small space of the used pressure cell. In part 2, we review our experimental results in search for pressure-induced superconductivity, which have been obtained by the use of developed techniques. Typical examples are shown in the case of simple inorganic and organic molecular crystals, ionic crystals, and magnetic metals.

  1. High pressure induced superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Amaya, K.; Shimizu, K

    2003-10-15

    We have developed complex extreme condition of very low temperature down to 30 mK and ultra high pressure exceeding 200 GPa by assembling compact diamond anvil cell (DAC) on a powerful {sup 3}He/{sup 4}He dilution refrigerator. We have also developed measuring techniques of electrical resistance, magnetization and optical measurement for the sample confined in the sample space of the DAC. Using the newly developed apparatus and techniques, we have searched for superconductivity in various materials under pressure. In this paper, we will shortly review our newly developed experimental apparatus and techniques and discuss a few examples of pressure induced superconductivity which were observed recently.

  2. Measurement of ethyl methanesulfonate in human plasma and breast milk samples using high-performance liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry.

    Science.gov (United States)

    Montesano, M Angela; Whitehead, Ralph D; Jayatilaka, Nayana K; Kuklenyik, Peter; Davis, Mark D; Needham, Larry L; Barr, Dana Boyd

    2010-06-05

    Ethyl methanesulfonate (EMS) is a mesylate ester, which is known to be a potent mutagen, teratogen, and possibly carcinogen. Mesylate esters have been found in pharmaceuticals as contaminants formed during the manufacturing process and may potentially pose an exposure hazard to humans. We have developed and validated a method for detection of trace amounts (ng/ml levels) of EMS in human plasma and breast milk. The samples were extracted by matrix solid-phase dispersion with ethyl acetate using Hydromatrix and the ASE 200 Accelerated Solvent Extractor. The extracts were separated by high-performance liquid chromatography (HPLC) using a HILIC column. The detection was performed with a triple quadrupole mass spectrometer (TSQ Quantum Ultra, Thermo Electron Corporation) using atmospheric pressure chemical ionization in negative-ion mode and multiple reaction monitoring. The use of a surrogate internal standard in combination with HPLC-MS/MS provided a high degree of accuracy and precision. The extraction efficiency was greater than 70%. Repeated analyses of plasma and breast milk samples spiked with high (100 ng/ml), medium (50 ng/ml) and low (5 ng/ml) concentrations of the analytes gave relative standard deviations of less than 12%. The limits of detection were in the range of 0.5-0.9 ng/ml for both matrices. Published by Elsevier B.V.

  3. Determination of fluoxetine and norfluoxetine in human plasma by high-pressure liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Raggi, M A; Mandrioli, R; Casamenti, G; Bugamelli, F; Volterra, V

    1998-10-01

    Fluoxetine is an atypical antidepressant drug, which selectively inhibits the neuronal reuptake of serotonin, and is widely used in the treatment of depressive disorders. The aim of this research is the development of an HPLC method with fluorescence detection for the monitoring of fluoxetine plasma levels. The determination requires no more than 250 microl of plasma, which undergo solid phase extraction (SPE), then are injected in the HPLC. For the analytical separation a reversed phase C8 column (150 x 4.6 mm I.D.) was used, while the mobile phase was a mixture of acetonitrile and water containing perchloric acid and tetramethylammonium perchlorate (flow rate: 1 ml min(-1)). The very low levels of analytes in plasma required the employment of a fluorescence detector (lambda(exc) = 230 nm, lambda(em)=290 nm), which also granted a good selectivity. Fluoxetine is revealed as a single peak at a retention time of 9.7 min, while norfluoxetine, the main metabolite of fluoxetine, is revealed at a retention time of 8.1 min. Linearity was obtained over the concentration range 8-200 ng ml(-1) for both substances. The method seems suitable, in accuracy and precision, for the determination of fluoxetine plasma levels of patients; furthermore, it is rapid and sensitive.

  4. High Blood Pressure Fact Sheet

    Science.gov (United States)

    ... High Blood Pressure Salt Cholesterol Million Hearts® WISEWOMAN High Blood Pressure Fact Sheet Language: English (US) Español (Spanish) Recommend ... time. High blood pressure is also called hypertension. High Blood Pressure in the United States Having high blood pressure ...

  5. Stimulation of wound healing by helium atmospheric pressure plasma treatment

    Science.gov (United States)

    Vasile Nastuta, Andrei; Topala, Ionut; Grigoras, Constantin; Pohoata, Valentin; Popa, Gheorghe

    2011-03-01

    New experiments using atmospheric pressure plasma have found large application in treatment of living cells or tissues, wound healing, cancerous cell apoptosis, blood coagulation on wounds, bone tissue modification, sterilization and decontamination. In this study an atmospheric pressure plasma jet generated using a cylindrical dielectric-barrier discharge was applied for treatment of burned wounds on Wistar rats' skin. The low temperature plasma jet works in helium and is driven by high voltage pulses. Oxygen and nitrogen based impurities are identified in the jet by emission spectroscopy. This paper analyses the natural epithelization of the rats' skin wounds and two methods of assisted epithelization, a classical one using polyurethane wound dressing and a new one using daily atmospheric pressure plasma treatment of wounds. Systemic and local medical data, such as haematological, biochemical and histological parameters, were monitored during entire period of study. Increased oxidative stress was observed for plasma treated wound. This result can be related to the presence in the plasma volume of active species, such as O and OH radicals. Both methods, wound dressing and plasma-assisted epithelization, provided positive medical results related to the recovery process of burned wounds. The dynamics of the skin regeneration process was modified: the epidermis re-epitelization was accelerated, while the recovery of superficial dermis was slowed down.

  6. Stimulation of wound healing by helium atmospheric pressure plasma treatment

    Energy Technology Data Exchange (ETDEWEB)

    Nastuta, Andrei Vasile; Topala, Ionut; Pohoata, Valentin; Popa, Gheorghe [Faculty of Physics, Alexandru Ioan Cuza University, Bd. Carol No. 11, 700506, Iasi (Romania); Grigoras, Constantin, E-mail: andrei.nastuta@uaic.ro [Physiopathology Department, Grigore T. Popa University of Medicine and Pharmacy, 700115, Iasi (Romania)

    2011-03-16

    New experiments using atmospheric pressure plasma have found large application in treatment of living cells or tissues, wound healing, cancerous cell apoptosis, blood coagulation on wounds, bone tissue modification, sterilization and decontamination. In this study an atmospheric pressure plasma jet generated using a cylindrical dielectric-barrier discharge was applied for treatment of burned wounds on Wistar rats' skin. The low temperature plasma jet works in helium and is driven by high voltage pulses. Oxygen and nitrogen based impurities are identified in the jet by emission spectroscopy. This paper analyses the natural epithelization of the rats' skin wounds and two methods of assisted epithelization, a classical one using polyurethane wound dressing and a new one using daily atmospheric pressure plasma treatment of wounds. Systemic and local medical data, such as haematological, biochemical and histological parameters, were monitored during entire period of study. Increased oxidative stress was observed for plasma treated wound. This result can be related to the presence in the plasma volume of active species, such as O and OH radicals. Both methods, wound dressing and plasma-assisted epithelization, provided positive medical results related to the recovery process of burned wounds. The dynamics of the skin regeneration process was modified: the epidermis re-epitelization was accelerated, while the recovery of superficial dermis was slowed down.

  7. Blood pressure and plasma catecholamines in acute and prolonged hypoxia

    DEFF Research Database (Denmark)

    Kanstrup, I L; Poulsen, T D; Hansen, J M

    1999-01-01

    and 5 days after rapid, passive transport to high altitude (4,559 m). Acute mountain sickness scores ranged from 5 to 16 (maximal attainable score: 20) on the first day but were reduced to 0-8 by the fifth day. Systolic blood pressure, heart rate, and plasma epinephrine increased on day 1 at altitude...... compared with sea level but declined again on day 5, whereas diastolic and mean blood pressures continued to rise in parallel with plasma norepinephrine. With local cooling, an increased vasoactive response was seen on the fifth day at altitude. Very high pressures were obtained, and the pressure elevation...... was prolonged. Heart rate increased twice as much on day 5 compared with the other two occasions. Thoracic fluid index increased with cooling on day 5, suggesting an increase in pulmonary vascular resistance. In conclusion, prolonged hypoxia seems to elicit an augmented pressor response to local cooling...

  8. Absolute atomic oxygen and nitrogen densities in radio-frequency driven atmospheric pressure cold plasmas: Synchrotron vacuum ultra-violet high-resolution Fourier-transform absorption measurements

    Energy Technology Data Exchange (ETDEWEB)

    Niemi, K.; O' Connell, D.; Gans, T. [York Plasma Institute, Department of Physics, University of York, York YO10 5DD (United Kingdom); Oliveira, N. de; Joyeux, D.; Nahon, L. [Synchrotron Soleil, l' Orme des Merisiers, St. Aubin BP 48, 91192 Gif sur Yvette Cedex (France); Booth, J. P. [Laboratoire de Physique des Plasmas-CNRS, Ecole Polytechnique, 91128 Palaiseau (France)

    2013-07-15

    Reactive atomic species play a key role in emerging cold atmospheric pressure plasma applications, in particular, in plasma medicine. Absolute densities of atomic oxygen and atomic nitrogen were measured in a radio-frequency driven non-equilibrium plasma operated at atmospheric pressure using vacuum ultra-violet (VUV) absorption spectroscopy. The experiment was conducted on the DESIRS synchrotron beamline using a unique VUV Fourier-transform spectrometer. Measurements were carried out in plasmas operated in helium with air-like N{sub 2}/O{sub 2} (4:1) admixtures. A maximum in the O-atom concentration of (9.1 {+-} 0.7) Multiplication-Sign 10{sup 20} m{sup -3} was found at admixtures of 0.35 vol. %, while the N-atom concentration exhibits a maximum of (5.7 {+-} 0.4) Multiplication-Sign 10{sup 19} m{sup -3} at 0.1 vol. %.

  9. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... pressures. Measuring Blood Pressure Blood pressure is the force of blood pushing against the walls of the ... blood pressure, sometimes called hypertension, happens when this force is too high. Health care workers check blood ...

  10. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... harder and leading to high blood pressure. Medicines Prescription medicines such as asthma or hormone therapies, including ... aldosterone system leading to high blood pressure. Other Medical Causes of High Blood Pressure Other medical causes ...

  11. High-beta plasma blobs in the morningside plasma sheet

    Directory of Open Access Journals (Sweden)

    G. Haerendel

    1999-12-01

    Full Text Available Equator-S frequently encountered, i.e. on 30% of the orbits between 1 March and 17 April 1998, strong variations of the magnetic field strength of typically 5–15-min duration outside about 9RE during the late-night/early-morning hours. Very high-plasma beta values were found, varying between 1 and 10 or more. Close conjunctions between Equator-S and Geotail revealed the spatial structure of these "plasma blobs" and their lifetime. They are typically 5–10° wide in longitude and have an antisymmetric plasma or magnetic pressure distribution with respect to the equator, while being altogether low-latitude phenomena  (≤ 15°. They drift slowly sunward, exchange plasma across the equator and have a lifetime of at least 15–30 min. While their spatial structure may be due to some sort of mirror instability, little is known about the origin of the high-beta plasma. It is speculated that the morningside boundary layer somewhat further tailward may be the source of this plasma. This would be consistent with the preference of the plasma blobs to occur during quiet conditions, although they are also found during substorm periods. The relation to auroral phenomena in the morningside oval is uncertain. The energy deposition may be mostly too weak to generate a visible signature. However, patchy aurora remains a candidate for more disturbed periods.Key words. Magnetospheric physics (plasma convection; plasma sheet; plasma waves and instabilities

  12. Atmospheric Pressure Plasma Processing for Polymer Adhesion: A Review

    DEFF Research Database (Denmark)

    Kusano, Yukihiro

    2014-01-01

    Atmospheric pressure plasma processing has attracted significant interests over decades due to its usefulness and a variety of applications. Adhesion improvement of polymer surfaces is among the most important applications of atmospheric pressure plasma treatment. Reflecting recent significant de...

  13. High Pressure Biomass Gasification

    Energy Technology Data Exchange (ETDEWEB)

    Agrawal, Pradeep K [Georgia Tech Research Corporation, Atlanta, GA (United States)

    2016-07-29

    According to the Billion Ton Report, the U.S. has a large supply of biomass available that can supplement fossil fuels for producing chemicals and transportation fuels. Agricultural waste, forest residue, and energy crops offer potential benefits: renewable feedstock, zero to low CO2 emissions depending on the specific source, and domestic supply availability. Biomass can be converted into chemicals and fuels using one of several approaches: (i) biological platform converts corn into ethanol by using depolymerization of cellulose to form sugars followed by fermentation, (ii) low-temperature pyrolysis to obtain bio-oils which must be treated to reduce oxygen content via HDO hydrodeoxygenation), and (iii) high temperature pyrolysis to produce syngas (CO + H2). This last approach consists of producing syngas using the thermal platform which can be used to produce a variety of chemicals and fuels. The goal of this project was to develop an improved understanding of the gasification of biomass at high pressure conditions and how various gasification parameters might affect the gasification behavior. Since most downstream applications of synags conversion (e.g., alcohol synthesis, Fischer-Tropsch synthesis etc) involve utilizing high pressure catalytic processes, there is an interest in carrying out the biomass gasification at high pressure which can potentially reduce the gasifier size and subsequent downstream cleaning processes. It is traditionally accepted that high pressure should increase the gasification rates (kinetic effect). There is also precedence from coal gasification literature from the 1970s that high pressure gasification would be a beneficial route to consider. Traditional approach of using thermogravimetric analyzer (TGA) or high-pressure themogravimetric analyzer (PTGA) worked well in understanding the gasification kinetics of coal gasification which was useful in designing high pressure coal gasification processes. However

  14. Simultaneous pressurized enzymatic hydrolysis extraction and clean up for arsenic speciation in seafood samples before high performance liquid chromatography-inductively coupled plasma-mass spectrometry determination.

    Science.gov (United States)

    Moreda-Piñeiro, Jorge; Alonso-Rodríguez, Elia; Moreda-Piñeiro, Antonio; Moscoso-Pérez, Carmen; Muniategui-Lorenzo, Soledad; López-Mahía, Purificación; Prada-Rodríguez, Darío; Bermejo-Barrera, Pilar

    2010-10-29

    The feasibility of pressurized conditions to assist enzymatic hydrolysis of seafood tissues for arsenic speciation was novelty studied. A simultaneous in situ (in cell) clean-up procedure was also optimized, which speeds up the whole sample treatment. Arsenic species (As(III), MMA, DMA, As(V), AsB and AsC) were released from dried seafood tissues using pepsin as a protease, and the arsenic species were separated/quantified by anion exchange high performance liquid chromatography (HPLC) coupled to inductively coupled plasma-mass spectrometry (ICP-MS). Variables inherent to the enzymatic activity (pH, temperature and ionic strength), the amount of enzyme (pepsin), and factors affecting pressurization (pressure, static time, number of cycles and amount of dispersing agent, C-18) were fully evaluated. Pressurized assisted enzymatic hydrolysis (PAEH) with pepsin can be finished after few minutes (two cycles of 2 min each one plus 3 min to reach the hydrolysis temperature of 50 °C). A total sample solubilisation is not achieved after the procedure, however it is efficient enough for breaking down certain bonds of bio-molecules and for releasing arsenic species. The developed method has been found to be precise (RSDs lower than 6% for As(III), DMA and As(V); and 3% for AsB) and sensitive (LOQs of 18.1, 36.2, 35.7, 28.6, 20.6 and 22.5 ng/g for As(III), MMA, DMA, As(V), AsB and AsC, respectively). The optimized methodology was successfully applied to different certified reference materials (DORM-2 and BCR 627) which offer certified AsB and DMA contents, and also to different seafood products (mollusks, white fishes and cold water fishes). Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... outlines and defines high blood pressure severity levels. Stages of High Blood Pressure in Adults Stages Systolic (top number) Diastolic (bottom number) Prehypertension 120– ...

  16. Aspirated High Pressure Compressor

    Science.gov (United States)

    2006-08-01

    suggested by the General Electric Company based on an advanced military engine concept intended for high speed flight. The resultant high flight...section, consisting of the two rotors, each on an computed points. The peak pressure ratio is 3.08 and the peak independent, electric motor-driven...instrumentation along Moto . .. ,oto2 with the test error analysis were given by Onnee [14). SFlywheel 2 BLOWDOWN OPERATION T--’..Exit-t-rottle

  17. Vacuolar H(+)-ATPase and plasma membrane H(+)-ATPase contribute to the tolerance against high-pressure carbon dioxide treatment in Saccharomyces cerevisiae.

    Science.gov (United States)

    Watanabe, Taisuke; Furukawa, Soichi; Kitamoto, Katsuhiko; Takatsuki, Akira; Hirata, Ryogo; Ogihara, Hirokazu; Yamasaki, Makari

    2005-11-25

    As a non-thermal sterilization process, high-pressure carbon dioxide treatment (HPCT) is considered to be promising. The main sterilizing effect of HPCT is thought to be acidification in cytoplasm of microorganisms. We investigated the tolerance mechanism of Saccharomyces cerevisiae to HPCT with special reference to vacuolar and plasma membrane H(+)-ATPases. HPCT was imposed at 35 degrees C, 4 to 10 MPa, for 10 min. slp1 mutant defective in vacuole morphogenesis was more sensitive to HPCT than its isogenic parent. Concanamycin A, a specific inhibitor of vacuolar H(+)-ATPase (V-ATPase), at 10 microM rendered the parent more HPCT-sensitive to the level of slp1. To confirm further the contribution of V-ATPase to the tolerance against HPCT in S. cerevisiae, we compared vma1 mutant of V-ATPase with its isogenic parent for their HPCT sensitivity. vma1 mutant was more sensitive to HPCT than its parent. Addition of 10 microM vanadate, an inhibitor of plasma membrane H(+)-ATPase (P-ATPase), to the wild type strains also increased the inactivation ratio. These results clearly show that V- and P-ATPases contribute to the tolerance against HPCT in S. cerevisiae by accumulating excess H(+) from cytoplasm to vacuole and excluding H(+) outside of the cell, respectively.

  18. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... page from the NHLBI on Twitter. Diagnosis of High Blood Pressure For most patients, health care providers ... are consistently 140/90 mmHg or above. Confirming High Blood Pressure A blood pressure test is easy ...

  19. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... blood pressure. Primary High Blood Pressure Primary, or essential, high blood pressure is the most common type ... has no known cause, it might be called essential hypertension, primary hypertension, or idiopathic (id-ee-o- ...

  20. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... from the NHLBI on Twitter. Diagnosis of High Blood Pressure For most patients, health care providers diagnose ... consistently 140/90 mmHg or above. Confirming High Blood Pressure A blood pressure test is easy and ...

  1. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... increase your risk for developing high blood pressure. Age Blood pressure tends to rise with age. About 65 percent of Americans age 60 or older have high blood pressure. However, ...

  2. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Home / < Back To Health Topics / High Blood Pressure High Blood Pressure Also known as Hypertension Leer en español See ... defines high blood pressure severity levels. Stages of High Blood Pressure in Adults Stages Systolic (top number) Diastolic (bottom ...

  3. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Home / < Back To Health Topics / High Blood Pressure High Blood Pressure Also known as Hypertension See also Information for ... defines high blood pressure severity levels. Stages of High Blood Pressure in Adults Stages Systolic (top number) Diastolic (bottom ...

  4. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... are two main types of high blood pressure: primary and secondary high blood pressure. Primary High Blood Pressure Primary, ... plan based on whether you were diagnosed with primary or secondary high blood pressure and if there is a ...

  5. Exploration to generate atmospheric pressure glow discharge plasma in air

    Science.gov (United States)

    Wenzheng, LIU; Chuanlong, MA; Shuai, ZHAO; Xiaozhong, CHEN; Tahan, WANG; Luxiang, ZHAO; Zhiyi, LI; Jiangqi, NIU; Liying, ZHU; Maolin, CHAI

    2018-03-01

    Atmospheric pressure glow discharge (APGD) plasma in air has high application value. In this paper, the methods of generating APGD plasma in air are discussed, and the characteristics of dielectric barrier discharge (DBD) in non-uniform electric field are studied. It makes sure that APGD in air is formed by DBD in alternating current electric field with using the absorbing electron capacity of electret materials to provide initial electrons and to end the discharge progress. Through designing electric field to form two-dimensional space varying electric field and three-dimensional space varying electric field, the development of electron avalanches in air-gap is suppressed effectively and a large space of APGD plasma in air is generated. Further, through combining electrode structures, a large area of APGD plasma in air is generated. On the other hand, by using the method of increasing the density of initial electrons, millimeter-gap glow discharge in atmospheric pressure air is formed, and a maximum gap distance between electrodes is 8 mm. By using the APGD plasma surface treatment device composed of contact electrodes, the surface modification of high polymer materials such as aramid fiber and polyester are studied and good effect of modifications is obtained. The present paper provides references for the researchers of industrial applications of plasma.

  6. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... increased blood volumes and high blood pressure. Sympathetic Nervous System Activity The sympathetic nervous system has important functions in blood pressure regulation, including ...

  7. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... High Blood Pressure Explore High Blood Pressure What Is... Other Names Causes Who Is at Risk Signs & Symptoms Diagnosis Treatments Prevention Living ... Confirming High Blood Pressure A blood pressure test is easy and painless and can be done in ...

  8. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... blood pressure: primary and secondary high blood pressure. Primary High Blood Pressure Primary, or essential, high blood pressure is the most ... known cause, it might be called essential hypertension, primary hypertension, or idiopathic (id-ee-o-PATH-ick) ...

  9. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... may stiffen small and large arteries, which can affect blood pressure. Genetic Causes of High Blood Pressure Much of the understanding of the body systems involved in high blood pressure has come from genetic studies. High blood pressure often runs in families. Years ...

  10. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... pressure and maintain normal blood pressure readings. Healthy Eating To help treat high blood pressure, health care ... more about the DASH eating plan. Heart-Healthy Eating Your health care provider also may recommend heart- ...

  11. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... can help you track your blood pressure. Pregnancy Planning High blood pressure can cause problems for mother ... With DASH My Blood Pressure Wallet Card Other Resources Cigarette and Tobacco Facts (National Institute ... OIG USA.gov

  12. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... providers diagnose high blood pressure when blood pressure readings are consistently 140/90 mmHg or above. Confirming ... minutes before the test. To track blood pressure readings over a period of time, the health care ...

  13. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Nervous System Activity The sympathetic nervous system has important functions in blood pressure regulation, including heart rate, ... prevent high blood pressure from developing. It is important to check your blood pressure regularly. Children should ...

  14. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... blood pressure, he or she can order additional tests to determine if your blood pressure is due to other conditions or medicines or if you have primary high blood pressure. ...

  15. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... of your blood pressure, he or she can order additional tests to determine if your blood pressure ... health and can lower high blood pressure. Stress management techniques include: Being physically active Listening to music ...

  16. Pressure Dome for High-Pressure Electrolyzer

    Science.gov (United States)

    Norman, Timothy; Schmitt, Edwin

    2012-01-01

    A high-strength, low-weight pressure vessel dome was designed specifically to house a high-pressure [2,000 psi (approx. = 13.8 MPa)] electrolyzer. In operation, the dome is filled with an inert gas pressurized to roughly 100 psi (approx. = 690 kPa) above the high, balanced pressure product oxygen and hydrogen gas streams. The inert gas acts to reduce the clamping load on electrolyzer stack tie bolts since the dome pressure acting axially inward helps offset the outward axial forces from the stack gas pressure. Likewise, radial and circumferential stresses on electrolyzer frames are minimized. Because the dome is operated at a higher pressure than the electrolyzer product gas, any external electrolyzer leak prevents oxygen or hydrogen from leaking into the dome. Instead the affected stack gas stream pressure rises detectably, thereby enabling a system shutdown. All electrical and fluid connections to the stack are made inside the pressure dome and require special plumbing and electrical dome interfaces for this to be accomplished. Further benefits of the dome are that it can act as a containment shield in the unlikely event of a catastrophic failure. Studies indicate that, for a given active area (and hence, cell ID), frame outside diameter must become ever larger to support stresses at higher operating pressures. This can lead to a large footprint and increased costs associated with thicker and/or larger diameter end-plates, tie-rods, and the frames themselves. One solution is to employ rings that fit snugly around the frame. This complicates stack assembly and is sometimes difficult to achieve in practice, as its success is strongly dependent on frame and ring tolerances, gas pressure, and operating temperature. A pressure dome permits an otherwise low-pressure stack to operate at higher pressures without growing the electrolyzer hardware. The pressure dome consists of two machined segments. An O-ring is placed in an O-ring groove in the flange of the bottom

  17. Stochastic Theory of Dust-Grain Charging in Low-Pressure Plasmas

    CERN Document Server

    Abolmasov, S N; Cabarrocas, P Roca i

    2013-01-01

    Charging of dust grains in low-pressure plasmas is reviewed critically. A theory based on the Fokker-Planck equation and orbital motion limited approximation is proposed. The theory predicts that dust grains can acquire a positive charge in low-pressure electropositive plasmas having a sufficiently high plasma potential, in agreement with experimental observations. It is also shown that variations in the plasma potential (electron temperature) can lead to spatial regions in which grains have opposite charges.

  18. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... control high blood pressure; lifestyle changes such as weight loss can be highly effective in treating high blood ... your risk for health problems. Greater amounts of weight loss can improve blood pressure readings, lower LDL cholesterol , ...

  19. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... care provider may need to change or add medicines to your treatment plan over time. NHLBI’s My Blood Pressure Wallet Card can help you track your blood pressure. Pregnancy Planning High blood pressure can cause problems for mother and baby. High blood pressure can ...

  20. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... mmHg or above. Confirming High Blood Pressure A blood pressure test is easy and painless and can be done ... high blood pressure. Using the results of your blood pressure test, your health care provider will diagnose prehypertension or ...

  1. High-beta plasma blobs in the morningside plasma sheet

    Directory of Open Access Journals (Sweden)

    G. Haerendel

    Full Text Available Equator-S frequently encountered, i.e. on 30% of the orbits between 1 March and 17 April 1998, strong variations of the magnetic field strength of typically 5–15-min duration outside about 9RE during the late-night/early-morning hours. Very high-plasma beta values were found, varying between 1 and 10 or more. Close conjunctions between Equator-S and Geotail revealed the spatial structure of these "plasma blobs" and their lifetime. They are typically 5–10° wide in longitude and have an antisymmetric plasma or magnetic pressure distribution with respect to the equator, while being altogether low-latitude phenomena 
    (≤ 15°. They drift slowly sunward, exchange plasma across the equator and have a lifetime of at least 15–30 min. While their spatial structure may be due to some sort of mirror instability, little is known about the origin of the high-beta plasma. It is speculated that the morningside boundary layer somewhat further tailward may be the source of this plasma. This would be consistent with the preference of the plasma blobs to occur during quiet conditions, although they are also found during substorm periods. The relation to auroral phenomena in the morningside oval is uncertain. The energy deposition may be mostly too weak to generate a visible signature. However, patchy aurora remains a candidate for more disturbed periods.

    Key words. Magnetospheric physics (plasma convection; plasma sheet; plasma waves and instabilities

  2. High Blood Pressure (Hypertension) (For Parents)

    Science.gov (United States)

    ... Pregnancy Healthy Food Shopping Healthy Drinks for Kids High Blood Pressure (Hypertension) KidsHealth > For Parents > High Blood Pressure (Hypertension) ... How Is High Blood Pressure Treated? What Is High Blood Pressure? Blood pressure is the pressure of blood against ...

  3. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... of physical activity Drinking too much alcohol Stress Family History A family history of high blood pressure raises the risk ... for high blood pressure and may run in families. Genetic causes of this condition are why family ...

  4. Medications for High Blood Pressure

    Science.gov (United States)

    ... Consumers Home For Consumers Consumer Updates Medications for High Blood Pressure Share Tweet Linkedin Pin it More sharing options ... age and you cannot tell if you have high blood pressure by the way you feel, so have your ...

  5. High blood pressure and diet

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007483.htm High blood pressure and diet To use the sharing features on ... diet is a proven way to help control high blood pressure . These changes can also help you lose weight ...

  6. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... can cause high blood pressure. Renin-Angiotensin-Aldosterone System The renin-angiotensin-aldosterone system makes angiotensin and ... blood volumes and high blood pressure. Sympathetic Nervous System Activity The sympathetic nervous system has important functions ...

  7. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... renin-angiotensin-aldosterone pathways. However, these known genetic factors only account for 2 to 3 percent of ... which leads to secondary high blood pressure. Risk Factors Anyone can develop high blood pressure; however, age, ...

  8. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Institute on Drug Abuse) High Blood Pressure (MedlinePlus) High Blood Pressure and Kidney Disease (National Institute of Diabetes and Digestive and Kidney Diseases) RELATED NEWS December ...

  9. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... habits. The combination of the medicines and the healthy lifestyle habits helps control and lower your high blood pressure. Some people develop “resistant” or uncontrolled high blood pressure. This ...

  10. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... control high blood pressure. Possible future treatments under investigation include new combination medicines, vaccines, and interventions aimed ... researchers on June 10, 2016, to share current scientific k... View all events on High Blood Pressure ...

  11. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... 139 OR 80–89 High blood pressure Stage 1 140–159 OR 90–99 High blood pressure ... To help make lifelong lifestyle changes, try making one healthy lifestyle change at a time and add ...

  12. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... potassium Lack of physical activity Drinking too much alcohol Stress Family History A family history of high blood pressure raises the risk of developing prehypertension or high blood pressure. Some ...

  13. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... and High Blood Pressure Researchers continue to study how various changes in normal body functions cause high ... to an increase in blood pressure. Aldosterone controls how the kidneys balance fluid and salt levels. Increased ...

  14. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Also known as Hypertension See also Information for Health Professionals What Is High blood pressure is a common ... Before age 55, men are more likely than women to develop high blood pressure. After age 55, ...

  15. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... hormones in your blood, which leads to secondary high blood pressure. Risk Factors Anyone can develop high blood pressure; however, age, race or ethnicity, being overweight, gender, ...

  16. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Ethnicity High blood pressure is more common in African American adults than in Caucasian or Hispanic American adults. Compared with these ethnic groups, African Americans: Tend to get high blood pressure earlier in ...

  17. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... being overweight or obese, and medicines. Unhealthy Lifestyle Habits Unhealthy lifestyle habits can cause high blood pressure, ... than men to develop high blood pressure. Lifestyle Habits Unhealthy lifestyle habits can raise your risk for ...

  18. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Imbalances in this kidney function can expand blood volumes, which can cause high blood pressure. Renin-Angiotensin- ... change this kidney function, leading to increased blood volumes and high blood pressure. Sympathetic Nervous System Activity ...

  19. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... for 2 to 3 percent of all cases. Emerging research suggests that certain DNA changes during fetal ... blood, which leads to secondary high blood pressure. Risk Factors Anyone can develop high blood pressure; however, ...

  20. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... of all cases. Emerging research suggests that certain DNA changes during fetal development also may cause the development of high blood pressure later in life. Environmental Causes of High Blood Pressure Environmental causes of ...

  1. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Advisory Committees Jobs Contact Us FAQs Home » Health Information for the Public » Health Topics » High Blood Pressure » Diagnosis of High Blood Pressure Explore High Blood Pressure What Is... Other Names Causes Who Is at Risk Signs & Symptoms Diagnosis Treatments Prevention Living With Clinical ...

  2. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... page from the NHLBI on Twitter. Diagnosis of High Blood Pressure For most patients, health care providers diagnose high ... are consistently 140/90 mmHg or above. Confirming High Blood Pressure A blood pressure test is easy and painless ...

  3. Ultra-high pressure liquid chromatography-tandem mass spectrometry method for the determination of omarigliptin in rat plasma and its application to a pharmacokinetic study in rats.

    Science.gov (United States)

    Li, Meng-Fang; Hu, Xiao-Xia; Ma, Ai-Qun

    2017-10-01

    Omarigliptin is a novel long-acting dipeptidyl peptidase-4 inhibitor used for the treatment of type 2 diabetes. In this work, a sensitive and selective ultra-high pressure liquid chromatography tandem mass spectrometry method was developed and validated for the determination of omarigliptin in rat plasma. Sample preparation was performed by protein precipitation with acetonitrile. Chromatographic separation of analytes was achieved on an RRHD Eclipse Plus C18 column (2.1 × 50 mm, 1.8 μm), using gradient mobile phase (0.1% formic acid-acetonitrile) at a flow rate of 0.4 mL/min. Detection was performed in multiple reaction monitoring mode, with target fragment ions m/z 399.1 → 152.9 for omarigliptin and m/z 237.1 → 194 for the internal standard. The total run time was 4 min. Retention time of omarigliptin and internal standard was 1.25 and 2.12 min, respectively. Relative standard deviation (%) of the intra- and inter-day precision was below 10.0%, and accuracy was between 97.9% and 105.3%. Calibration curve was established over the range 2-5000 ng/mL with good linearity. The lower limit of quantification and limit of detection of omarigliptin were 2 and 0.25 ng/mL, respectively. Mean recoveries were in the range 87.3-95.1% for omarigliptin. No matrix effect was observed in this method. This novel method has been successfully applied to a pharmacokinetic study of omarigliptin in rats. The absolute bioavailability of omarigliptin was identified as high as 87.31%. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Atmospheric Pressure Low Temperature Plasma System for Additive Manufacturing

    Science.gov (United States)

    Burnette, Matthew; Staack, David

    2016-09-01

    There is growing interest in using plasmas for additive manufacturing, however these methods use high temperature plasmas to melt the material. We have developed a novel technique of additive manufacturing using a low temperature dielectric barrier discharge (DBD) jet. The jet is attached to the head of a 3D printer to allow for precise control of the plasma's location. Various methods are employed to deposit the material, including using a vaporized precursor or depositing a liquid precursor directly onto the substrate or into the plasma via a nebulizer. Various materials can be deposited including metals (copper using copper (II) acetylacetonate), polymers (PMMA using the liquid monomer), and various hydrocarbon compounds (using alcohols or a 100% methane DBD jet). The rastering pattern for the 3D printer was modified for plasma deposition, since it was originally designed for thermoplastic extrusion. The design constraints for fill pattern selection for the plasma printer are influenced by substrate heating, deposition area, and precursor consumption. Depositions onto pressure and/or temperature sensitive substrates can be easily achieved. Deposition rates range up to 0.08 cm3/hr using tris(2-methoxyethoxy)(vinyl)silane, however optimization can still be done on the system to improve the deposition rate. For example higher concentration of precursor can be combined with faster motion and higher discharge powers to increase the deposition rate without overheating the substrate.

  5. Application of atmospheric pressure plasma in polymer and composite adhesion

    Science.gov (United States)

    Yu, Hang

    An atmospheric pressure helium and oxygen plasma was used to investigate surface activation and bonding in polymer composites. This device was operated by passing 1.0-3.0 vol% of oxygen in helium through a pair of parallel plate metal electrodes powered by 13.56 or 27.12 MHz radio frequency power. The gases were partially ionized between the capacitors where plasma was generated. The reactive species in the plasma were carried downstream by the gas flow to treat the substrate surface. The temperature of the plasm gas reaching the surface of the substrate did not exceed 150 °C, which makes it suitable for polymer processing. The reactive species in the plasma downstream includes ~ 1016-1017 cm-3 atomic oxygen, ~ 1015 cm-3 ozone molecule, and ~ 10 16 cm-3 metastable oxygen molecule (O2 1Deltag). The substrates were treated at 2-5 mm distance from the exit of the plasma. Surface properties of the substrates were characterized using water contact angle (WCA), atomic force microscopy (AFM), infrared spectroscopy (IR), and X-ray photoelectron spectroscopy (XPS). Subsequently, the plasma treated samples were bonded adhesively or fabricated into composites. The increase in mechanical strength was correlated to changes in the material composition and structure after plasma treatment. The work presented hereafter establishes atmospheric pressure plasma as an effective method to activate and to clean the surfaces of polymers and composites for bonding. This application can be further expanded to the activation of carbon fibers for better fiber-resin interactions during the fabrication of composites. Treating electronic grade FR-4 and polyimide with the He/O2 plasma for a few seconds changed the substrate surface from hydrophobic to hydrophilic, which allowed complete wetting of the surface by epoxy in underfill applications. Characterization of the surface by X-ray photoelectron spectroscopy shows formation of oxygenated functional groups, including hydroxyl, carbonyl, and

  6. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Blood Pressure Much of the understanding of the body systems involved in high blood pressure has come from ... happens because medicines can change the way your body controls fluid and salt ... system leading to high blood pressure. Other Medical Causes ...

  7. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Card can help you track your blood pressure. Pregnancy Planning High blood pressure can cause problems for mother and ... before and during the pregnancy. Some women develop high blood pressure during pregnancy. When this happens, your health care provider will ...

  8. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... other conditions or medicines or if you have primary high blood pressure. Health care providers can use this information to develop your ... blood pressure persists or is first diagnosed as primary high blood pressure, your ... your health care provider may change or update your treatment plan ...

  9. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... for the test: Don’t drink coffee or smoke cigarettes for 30 minutes prior to the test. Go ... DASH My Blood Pressure Wallet Card Other Resources Cigarette and Tobacco Facts (National Institute on Drug Abuse) High Blood Pressure (MedlinePlus) High Blood Pressure ...

  10. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Diagnosis of High Blood Pressure For most patients, health care providers diagnose high blood pressure when blood pressure ... and painless and can be done in a health care provider’s office or clinic. To prepare for the ...

  11. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... above. Confirming High Blood Pressure A blood pressure test is easy and painless and can be done ... provider’s office or clinic. To prepare for the test: Don’t drink coffee or smoke cigarettes for ...

  12. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... too high. Health care workers check blood pressure readings the same way for children, teens, and adults. ... Complications Because diagnosis is based on blood pressure readings, this condition can go undetected for years, as ...

  13. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... severity levels. Stages of High Blood Pressure in Adults Stages Systolic (top number) Diastolic (bottom number) Prehypertension ... in the table are blood pressure guides for adults who do not have any short-term serious ...

  14. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... check blood pressure readings the same way for children, teens, and adults. They use a gauge, stethoscope ... prehypertension and high blood pressure is increasing for children and teens, possibly due to the rise in ...

  15. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... and to follow your prescribed treatment plan, which will include healthy lifestyle habit recommendations and possibly medicines. ... your blood pressure test, your health care provider will diagnose prehypertension or high blood pressure if: Your ...

  16. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... American adults. Compared with these ethnic groups, African Americans: Tend to get high blood pressure earlier in life. Often, on average, have higher blood pressure numbers. ...

  17. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... increase your risk for developing high blood pressure. Age Blood pressure tends to rise with age. About ... mother’s kidneys and other organs and can cause early birth and low birth weight. If you’re ...

  18. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... condition is leading to uncontrolled blood pressure. Health care providers treat resistant or uncontrolled high blood pressure with an intensive treatment plan that can include a different set ...

  19. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... risk for prehypertension and high blood pressure is increasing for children and teens, possibly due to the ... II is a hormone that narrows blood vessels, increasing blood pressure. ACE converts Angiotensin I to Angiotensin ...

  20. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... may stiffen small and large arteries, which can affect blood pressure. Genetic Causes of High Blood Pressure ... which plaque builds up in leg arteries and affects blood flow in the legs. When people have ...

  1. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... work harder and leading to high blood pressure. Medicines Prescription medicines such as asthma or hormone therapies, ... or peaceful Performing yoga or tai chi Meditating Medicines Blood pressure medicines work in different ways to ...

  2. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Operations and Administration Advisory Committees Budget and Legislative Information Jobs and Working at the NHLBI Contact and ... Blood Pressure Also known as Hypertension See also Information for Health Professionals What Is High blood pressure ...

  3. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... or tai chi Meditating Medicines Blood pressure medicines work in different ways to stop or slow some of the body’s functions that cause high blood pressure. Medicines to lower ...

  4. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... can help you track your blood pressure. Pregnancy Planning High blood pressure can cause problems for mother ... babies have good outcomes. Participate in NHLBI Clinical Trials The National Heart, Lung, and Blood Institute (NHLBI) ...

  5. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... health and can lower high blood pressure. Stress management techniques include: Being physically active Listening to music ... With DASH My Blood Pressure Wallet Card Other Resources Cigarette and Tobacco Facts (National Institute on ... OIG USA.gov

  6. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... structure and function. Biology and High Blood Pressure Researchers continue to study how various changes in normal ... including heart rate, blood pressure, and breathing rate. Researchers are investigating whether imbalances in this system cause ...

  7. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... health and can lower high blood pressure. Stress management techniques include: Being physically active Listening to music ... Blood Pressure and Kidney Disease (National Institute of Diabetes and Digestive and Kidney Diseases) RELATED NEWS December ...

  8. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... ask for your readings. Blood Pressure Severity and Type Your health care provider usually takes 2–3 ... any other location. Health care providers diagnose this type of high blood pressure by reviewing readings in ...

  9. High Blood Pressure in Pregnancy

    Science.gov (United States)

    ... of the baby. Controlling your blood pressure during pregnancy and getting regular prenatal care are important for ... your baby. Treatments for high blood pressure in pregnancy may include close monitoring of the baby, lifestyle ...

  10. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... lead to cognitive changes. Signs and symptoms include memory loss, difficulty finding words, and losing focus during ... above. Confirming High Blood Pressure A blood pressure test is easy and painless and can be done ...

  11. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... weakens and damages your blood vessels, which can lead to complications . Types of High Blood Pressure There ... Angiotensin narrows or constricts blood vessels, which can lead to an increase in blood pressure. Aldosterone controls ...

  12. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... to keep a written log of all your results. Whenever you have an appointment with the health ... appointments to diagnose high blood pressure. Using the results of your blood pressure test, your health care ...

  13. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... your blood vessels, which can lead to complications . Types of High Blood Pressure There are two main ... ask for your readings. Blood Pressure Severity and Type Your health care provider usually takes 2–3 ...

  14. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... lifestyle habits, proper use of medicines, and regular medical care can prevent high blood pressure or its complications. ... blood pressure, it is important to obtain regular medical care and to follow your prescribed treatment plan, which ...

  15. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... system activity , and blood vessel structure and function. Biology and High Blood Pressure Researchers continue to study ... blood pressure often runs in families. Years of research have identified many genes and other mutations associated ...

  16. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... is too high. Health care workers check blood pressure readings the same way for children, teens, and adults. They use a gauge, stethoscope or electronic sensor, and a blood pressure ...

  17. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... and Obesity Smoking and Your Heart Stroke Send a link to NHLBI to someone by E-MAIL | ... 90 mmHg or above. Confirming High Blood Pressure A blood pressure test is easy and painless and ...

  18. High pressure direct injection

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, J. [Cummins Westport Inc., Vancouver, BC (Canada)

    2002-07-01

    A brief overview of Cummins Westport was provided, indicating that Westport originated in the 1980s through a research team at the University of British Columbia, and the hiring of the first employees began in 1996. The joint venture between Cummins and Westport was formed in March 2001. Cummins is the largest builder of commercial diesels in the world, and Westport is a small incubation technology company with emphasis on natural gas. The contribution of each company benefits the joint venture. Cummins brings traditional expertise in product and process development and distribution system, while Westport contributes new high pressure direct injection (HPDI) technology, funding and enthusiasm. The same base engine is kept and only the fuel system is changed. HPDI uses diesel cycle combustion and diesel pilot ignites natural gas. It allows for low emissions, high performance, high efficiency and economic payback. The pilot-ignited HPDI technology was explained, and its application to large class-8 trucks was discussed. The efficiency and performance of diesel engines is maintained by HPDI technology, there are 40 per cent reductions in nitrous oxide emissions, particulate matter emissions are reduced by 60 per cent, and carbon dioxide emissions are reduced by 20 per cent. A field demonstration was reviewed, and the major test at Norcal in San Francisco was discussed. The key success factors were found to be: formalized customer support plan, on-site technical support, parts availability, driver support and interaction, and training. Liquid natural gas fuel contamination was found to cause component wear. The emphasis has now been placed on three issues: injector life improvements, fuel debris and liquid natural gas pump/dome regulator life, and fuel economy improvements. The accomplishments for 2001 were identified, such as rapidly improving reliability, 17 HPDI trucks are upfit and in-service to name a few. The goals for 2002 include the placement of permanent fuel

  19. Development of atmospheric pressure plasma needle jet for sterilization applications

    Science.gov (United States)

    Elfa, Rizan Rizon; Ahmad, Mohd Khairul; Soon, Chin Fhong; Sahdan, Mohd Zainizan; Lias, Jais; Wibowo, Kusnanto Mukti; Bakar, Ahmad Shuhaimi Abu; Arshad, Mohd Khairuddin Md; Hashim, Uda; Nayan, Nafarizal

    2017-09-01

    Inactivation of bacteria or sterilization has been a major issue in the medical field, especially regarding of human safety, whereby, in a huge scenario fatality can be caused by hazardous bacteria. Often, E-coli as gram-negative bacteria are selected as a key indicator of proper sterilization process as E-coli is tough and dormant bacteria. The technology in sterilization has moved on from chemical, wet and irradiation sterilization to a high promising device such as atmospheric pressure plasma needle jet (APPNJ). It has been reported that atmospheric pressure plasma has provided bundle of advantages over earlier sterilization process. The APPNJ is developed in our lab using high frequency and high voltage neon transformer power supply connected to copper needle and copper sheet electrodes. The gas discharge is Ar gas flowing at 40 L/min through a quartz glass tube. The E-coli bacteria are self-cultured from waste water and then treated with APPNJ. The treatment processes are run into two difference gaps between the plasma orifice and sample with various treatment times. Only 40s is required by direct treatment to achieve 100% killing of E-coli. On the other hand, indirect treatment has inactivated 50% of the E-coli in 40s. In this study, direct and indirect effect of APPNJ to the E-coli can be observed which can be utilized into sterilization of bio-compatible material applications.

  20. Foundations of atmospheric pressure non-equilibrium plasmas

    Science.gov (United States)

    Bruggeman, Peter J.; Iza, Felipe; Brandenburg, Ronny

    2017-12-01

    Non-equilibrium plasmas have been intensively studied over the past century in the context of material processing, environmental remediation, ozone generation, excimer lamps and plasma display panels. Research on atmospheric pressure non-equilibrium plasmas intensified over the last two decades leading to a large variety of plasma sources that have been developed for an extended application range including chemical conversion, medicine, chemical analysis and disinfection. The fundamental understanding of these discharges is emerging but there remain a lot of unexplained phenomena in these intrinsically complex plasmas. The properties of non-equilibrium plasmas at atmospheric pressure span over a huge range of electron densities as well as heavy particle and electron temperatures. This paper provides an overview of the key underlying processes that are important for the generation and stabilization of atmospheric pressure non-equilibrium plasmas. The unique physical and chemical properties of theses discharges are also summarized.

  1. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... blood pressure and maintain normal blood pressure readings. Healthy Eating To help treat high blood pressure, health care providers recommend that you limit sodium and salt intake, increase potassium, and eat foods that are heart healthy. Limiting Sodium and Salt ...

  2. Dynamics of apokamp-type atmospheric pressure plasma jets

    Science.gov (United States)

    Sosnin, Eduard A.; Panarin, Victor A.; Skakun, Victor S.; Baksht, Evgeny Kh.; Tarasenko, Victor F.

    2017-02-01

    The paper describes a new discharge source of atmospheric pressure plasma jets (APPJs) in air with no gas supply through the discharge region. In this discharge mode, plasma jets develop from the bending point of a bright current channel between two electrodes and are therefore termed an apokamp (from Greek `off' and `bend'). The apokamp can represent single plasma jets of length up 6 cm or several jets, and the temperature of such jets can range from more than 1000 °C at their base to 100-250 °C at their tip. Apokamps are formed at maximum applied voltage of positive polarity, provided that the second electrode is capacitively decoupled with ground. According to high-speed photography with time resolution from several nanoseconds to several tens of nanoseconds, the apokamp consists of a set of plasma bullets moving with a velocity of 100-220 km/s, which excludes the convective mechanism of plasma decay. Estimates on a 100-ns scale show that the near-electrode zones and the zones from which apokamps develop are close in temperature.

  3. Diamond-like carbon film preparation using a high-repetition nanosecond pulsed glow discharge plasma at gas pressure of 1 kPa generated by a SiC-MOSFET inverter power supply

    Science.gov (United States)

    Kikuchi, Yusuke; Ogura, Masataka; Maegawa, Takuya; Otsubo, Akira; Nishimura, Yoshimi; Nagata, Masayoshi; Yatsuzuka, Mitsuyasu

    2017-10-01

    A high-repetition nanosecond pulsed glow discharge plasma at a gas pressure of 1 kPa was generated using a SiC-MOSFET inverter power supply for diamond-like carbon (DLC) film preparation. At a high repetition frequency above 50 kHz, the period of the nanosecond voltage pulse became shorter than the decay time of the afterglow plasma, and many ions and radicals remained in the gap space. The deposition rate was 0.1 µm/min, which was 5 times higher than that of a conventional plasma CVD process. An increase in hardness to 13 GPa and a decrease in hydrogen content in the DLC film were confirmed by increasing the repetition frequency to 200 kHz.

  4. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... of Intramural Research Research Resources Research Meeting Summaries Technology Transfer ... » Health Information for the Public » Health Topics » High Blood Pressure » ...

  5. What Is High Blood Pressure?

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More What is High Blood Pressure? Updated:Oct 5,2017 First, let’s define high ... resources . This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  6. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... to cognitive changes. Signs and symptoms include memory loss, difficulty finding words, and losing focus during conversations. ... high blood pressure; lifestyle changes such as weight loss can be highly effective in treating high blood ...

  7. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... control high blood pressure; lifestyle changes such as weight loss can be highly effective in treating high blood ... If you’re overweight or obese, try to lose weight. A loss of just 3 to 5 percent ...

  8. Atmospheric pressure plasma for surface modification

    CERN Document Server

    Wolf, Rory A

    2012-01-01

    This Book's focus and intent is to impart an understanding of the practical application of atmospheric plasma for the advancement of a wide range of current and emerging technologies. The primary key feature of this book is the introduction of over thirteen years of practical experimental evidence of successful surface modifications by atmospheric plasma methods. It offers a handbook-based approach for leveraging and optimizing atmospheric plasma technologies which are currently in commercial use. It also offers a complete treatment of both basic plasma physics and industrial plasma process

  9. A High Density ECRH Plasma Source

    Science.gov (United States)

    Simon, M.; Rosenthal, G.; Kidd, P.; Wuerker, R.; Wong, A. Y.; Siciliano, E. R.

    1996-11-01

    An ECRH plasma source has been constructed within a 10 kG solenoid, using a 10 kW (max) of CW 10.6 GHz klystron amplifier. Vacuum base pressures are on the order of 10-7 torr. One kW of CW ECRH microwave power is sufficient to create a high density (10^12 cm-3) fully ionized pure calcium metal plasma, the maximum theoretically possible at 10.6 GHz. The electron temperature is around 10 eV. Neutral Ca is evaporated through the ECRH resonance zone from a thermal oven. Only ions (not neutrals) trapped by the field enter the main chamber, resulting in a fully ionized plasma. The source is useful for generating fully ionized pure plasmas from low melting point materinals. Work Supported by NSF PHY-94-21693

  10. Effects of varying subatmospheric pressure on stationary plasma arc welds

    Science.gov (United States)

    Chin, J. J.; Rubinsky, B.

    1991-01-01

    An experimental study was performed examining the variation of penetration, fluid behavior, heat-affected zone and arc in plasma arc welding (PAW) with respect to subatmospheric ambient pressure. The results reveal nonlinear variation of keyhole size, time of penetration, and size of the heat-affected zone with pressure. In a restricted range of pressure, dynamic components of fluid flow directed out of the molten pool appear and have a profound effect on keyhole formation. The generated plasma arc is observed to decrease in intensity with decreasing pressure, resulting in a reduction of penetration at lower pressures.

  11. Pressure and compressibility in a quantum one-component plasma

    NARCIS (Netherlands)

    John, P.; Suttorp, L.G.

    1994-01-01

    With the help of scaling methods, a general relation is established between the thermodynamic pressure and the mechanical pressure tensor of an equilibrium one-component plasma in a magnetic field. The mechanical pressure tenser is shown to be anisotropic. A general proof of the compressibility sum

  12. High Blood Pressure and Women

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More High Blood Pressure and Women Updated:Dec 14,2016 Pregnancy and ... Women . This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  13. Common High Blood Pressure Myths

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Common High Blood Pressure Myths Updated:Dec 8,2017 Knowing the facts ... health. This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  14. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... other conditions or medicines or if you have primary high blood pressure. Health care providers can use this information to develop your treatment plan. Some people have “white coat hypertension.” This happens when blood pressure readings are only high when taken in a health ...

  15. High Pressure Research on Materials

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 12; Issue 6. High Pressure Research on Materials - Production and Measurement of High Pressures in the Laboratory. P Ch Sahu N V Chandra Shekar. General Article Volume 12 Issue 6 June 2007 pp 10-23 ...

  16. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... cause high blood pressure. Blood Vessel Structure and Function Changes in the structure and function of small and large arteries may contribute to ... to stop or slow some of the body’s functions that cause high blood pressure. Medicines to lower ...

  17. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... can help you control high blood pressure. These habits include: Healthy eating Being physically active Maintaining a healthy weight Limiting ... earlier changes. When you practice several healthy lifestyle habits, you are more likely to lower ... Eating To help treat high blood pressure, health care ...

  18. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... provider’s office compared with readings taken in any other location. Health care providers diagnose this type of high blood pressure ... high blood pressure and reduce your risk for other health problems. Talk with your health care provider before you start a new exercise plan. ...

  19. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Stroke Other Resources Many resources are available for support and to provide additional information on high blood pressure not found elsewhere in this Health Topic. NHLBI Resources Healthy Hearts, Healthy Homes: Keep the Beat: Control Your High Blood Pressure/ ...

  20. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... numbers are too high. Causes Changes, either from gene or the environment, in the body’s normal functions ... in families. Years of research have identified many genes and other mutations associated with high blood pressure, ...

  1. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... of physical activity Drinking too much alcohol Stress Family History A family history of high blood pressure ... Stroke Other Resources Many resources are available for support and to provide additional information on high blood ...

  2. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... for a certain height. Gender Before age 55, men are more likely than women to develop high ... After age 55, women are more likely than men to develop high blood pressure. Lifestyle Habits Unhealthy ...

  3. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... system activity , and blood vessel structure and function. Biology and High Blood Pressure Researchers continue to study ... balances, cause your blood vessels to constrict, or impact the renin-angiotensin-aldosterone system leading to high ...

  4. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... numbers are too high. Causes Changes, either from genes or the environment, in the body’s normal functions ... in families. Years of research have identified many genes and other mutations associated with high blood pressure, ...

  5. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... a risk factor for this condition. Screening and Prevention Healthy lifestyle habits, proper use of medicines, and regular medical care can prevent high blood pressure or its complications. Preventing High ...

  6. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... treatment plans for high blood pressure that include lifelong lifestyle changes and medicines to control high blood ... Managing and coping with stress To help make lifelong lifestyle changes, try making one healthy lifestyle change ...

  7. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... be highly effective in treating high blood pressure. Treatment Plans Health care providers work with you to ... be changed or a new medicine prescribed. Future Treatments Scientists, doctors, and researchers continue to study the ...

  8. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... habits, being overweight or obese, and medicines. Unhealthy Lifestyle Habits Unhealthy lifestyle habits can cause high blood ... likely than men to develop high blood pressure. Lifestyle Habits Unhealthy lifestyle habits can raise your risk ...

  9. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... estrogen, and over-the-counter medicines such as cold relief medicines may cause this form of high ... blood pressure stays high over time, it can damage the body and cause complications. Some common complications ...

  10. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... 120/80 mmHg. The following table outlines and defines high blood pressure severity levels. Stages of High ... American College of Cardiology (ACC), the guidelines now define hypertension as a systolic blood... View all news ...

  11. Production and modification of hollow powders in plasma under controlled pressure

    Science.gov (United States)

    Gulyaev, Igor P.

    2013-06-01

    Conducting plasma processes under high or low pressure is an efficient way to affect the heat, mass and momentum exchange in a two-phase flow and this technique is widely used in such well-developed technologies as low-pressure plasma spraying (LPPS) and high pressure plasma-chemical processes. In addition operating pressure is a key parameter in novel plasma process for modification of hollow powders properties. Plasma processing of porous ceramic powders is an effective method of producing hollow spheres (HOSP) with predefined properties. Regardless the method hollow powders were produced their geometric and structural properties can be adjusted by re-melting in plasma of certain pressure: low pressure processing will expand hollow spheres and high pressure - contract it. Regulating the outer diameter of hollow sphere allows adjusting its shell thickness, apparent density, gas pressure in the cavity etc. Preliminary experiments with zirconia hollow powders demonstrated good agreement with theoretical estimations of HOSP properties. The same technique can be used for adjusting properties of ceramic hollow powders produced by different methods, including cost effective fly-ash particles (cenospheres).

  12. Method development for the determination of 24S-hydroxycholesterol in human plasma without derivatization by high-performance liquid chromatography with tandem mass spectrometry in atmospheric pressure chemical ionization mode.

    Science.gov (United States)

    Sugimoto, Hiroshi; Kakehi, Masaaki; Satomi, Yoshinori; Kamiguchi, Hidenori; Jinno, Fumihiro

    2015-10-01

    We developed a highly sensitive and specific high-performance liquid chromatography with tandem mass spectrometry method with an atmospheric pressure chemical ionization interface to determine 24S-hydroxycholesterol, a major metabolite of cholesterol formed by cytochrome P450 family 46A1, in human plasma without any derivatization step. Phosphate buffered saline including 1% Tween 80 was used as the surrogate matrix for preparation of calibration curves and quality control samples. The saponification process to convert esterified 24S-hydroxycholesterol to free sterols was optimized, followed by liquid-liquid extraction using hexane. Chromatographic separation of 24S-hydroxycholesterol from other isobaric endogenous oxysterols was successfully achieved with gradient mobile phase comprised of 0.1% propionic acid and acetonitrile using L-column2 ODS (2 μm, 2.1 mm id × 150 mm). This assay was capable of determining 24S-hydroxycholesterol in human plasma (200 μL) ranging from 1 to 100 ng/mL with acceptable intra- and inter-day precision and accuracy. The potential risk of in vitro formation of 24S-hydroxycholesterol by oxidation from endogenous cholesterol in human plasma was found to be negligible. The stability of 24S-hydroxycholesterol in relevant solvents and human plasma was confirmed. This method was successfully applied to quantify the plasma concentrations of 24S-hydroxycholesterol in male and female volunteers. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Hypertension (High Blood Pressure)

    Science.gov (United States)

    ... blood vessels, induction of a high fever, and strict low-sodium diets. Case studies suggested that each ... with scientific and medical communities to update hypertension management guidelines (JNC-8), including integrating them with updated ...

  14. Non-Thermal Sanitation By Atmospheric Pressure Plasma Project

    Data.gov (United States)

    National Aeronautics and Space Administration — ORBITEC's Non-Thermal Sanitation by Atmospheric Pressure Plasma technology sanitizes fresh fruits and vegetables without the use of consumable chemicals and without...

  15. Non-Thermal Sanitation By Atmospheric Pressure Plasma Project

    Data.gov (United States)

    National Aeronautics and Space Administration — ORBITEC proposes to develop a non-thermal technology based on atmospheric-pressure (AP) cold plasma to sanitize foods, food packaging materials, and other hardware...

  16. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... health and can lower high blood pressure. Stress management techniques include: Being physically active Listening to music or focusing on something calm or peaceful Performing yoga or tai chi Meditating Medicines Blood pressure medicines work in different ways to stop or slow some of the ...

  17. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... of Intramural Research Research Resources Research Meeting Summaries Technology Transfer Clinical Trials What Are Clinical Trials? Children & ... or at other locations that have blood pressure equipment and to keep a written ... at several medical appointments to diagnose high blood pressure. Using the ...

  18. High Pressure Research on Materials

    Indian Academy of Sciences (India)

    basic types of apparatus that are now being used throughout the world. He was awarded the Nobel Prize in Physics in 1946. The static high pressure generating devices can be divided into two categories: piston-cylinder and opposed anvil devices. These devices with their pressure capabilities are listed in Figure 4.

  19. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... pressure readings, lower LDL cholesterol , and increase HDL cholesterol . However, research shows that no matter your weight, it is important to control high blood pressure to maintain good health. A useful measure of overweight and obesity is body mass index (BMI). BMI measures your ...

  20. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... learn how to check your blood pressure at home. Your health care provider can help you learn how to do ... to lower the chance of complications. With such care, most women and babies have good ... Resources Healthy Hearts, Healthy Homes: Keep the Beat: Control Your High Blood Pressure/ ...

  1. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... NHLBI About NHLBI Home Mission and Strategic Vision Leadership Scientific Divisions Operations and Administration Advisory Committees Budget ... health and can lower high blood pressure. Stress management techniques include: Being physically ... SPRINT trial played a key role in the evolution of the new blood pressure ...

  2. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... physical health and can lower high blood pressure. Stress management techniques include: Being physically active Listening to music or focusing on something calm or peaceful Performing yoga or tai chi Meditating Medicines Blood pressure medicines work in different ways to stop or slow some ...

  3. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... NHLBI About NHLBI Home Mission and Strategic Vision Leadership Scientific Divisions Operations and Administration Advisory Committees Budget ... health and can lower high blood pressure. Stress management techniques include: Being physically ... pressure medicines work in different ways to stop or slow some of the ...

  4. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... or focusing on something calm or peaceful Performing yoga or tai chi Meditating Medicines Blood pressure medicines work in different ways to stop or slow some of the body’s functions that cause high blood pressure. Medicines to ...

  5. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Severity and Type Your health care provider usually takes 2–3 readings at several medical appointments to diagnose high blood pressure. Using the results of your blood pressure test, your health care provider will diagnose prehypertension or ...

  6. Cellular membrane collapse by atmospheric-pressure plasma jet

    Science.gov (United States)

    Kim, Kangil; Jun Ahn, Hak; Lee, Jae-Hyeok; Kim, Jae-Ho; Sik Yang, Sang; Lee, Jong-Soo

    2014-01-01

    Cellular membrane dysfunction caused by air plasma in cancer cells has been studied to exploit atmospheric-pressure plasma jets for cancer therapy. Here, we report that plasma jet treatment of cervical cancer HeLa cells increased electrical conductivity across the cellular lipid membrane and caused simultaneous lipid oxidation and cellular membrane collapse. We made this finding by employing a self-manufactured microelectrode chip. Furthermore, increased roughness of the cellular lipid membrane and sequential collapse of the membrane were observed by atomic force microscopy following plasma jet treatment. These results suggest that the cellular membrane catastrophe occurs via coincident altered electrical conductivity, lipid oxidation, and membrane roughening caused by an atmospheric-pressure plasma jet, possibly resulting in cellular vulnerability to reactive species generated from the plasma as well as cytotoxicity to cancer cells.

  7. Reactivity zones around an atmospheric pressure plasma jet

    Energy Technology Data Exchange (ETDEWEB)

    Birer, Özgür, E-mail: obirer@ku.edu.tr

    2015-11-01

    Highlights: • Polyethylene surfaces were treated with atmospheric pressure cold plasma jet. • The effect of plasma extends beyond the physical jet diameter. • Moieties of –NO, –COO, –CO and –NO{sub 3} as expanding ring patterns were detected. • Active species in the plasma are identified for specific surface moieties. - Abstract: The reactivity zones around an atmospheric pressure plasma jet are revealed by XPS mapping of chemical moieties on a polyethylene surface treated with a 3-mm plasma jet. The area directly hit by the helium plasma jet initially oxidizes and later etches away as the plasma treatment continues. The oxidation initially starts at the center and expands outwards as a ring pattern with different spatial potency. At the end of 10 min plasma jet treatment, distinct ring patterns for –NO, –COO, –CO and –NO{sub 3} species can be detected with respectively increasing diameters. The plasma jet can cause chemical changes at locations several millimeters away from the center. The spatial distribution of oxidized species suggests presence of chemical reactivity zones. Introduction of nitrogen into the helium plasma jet, not only increases the type of nitrogen moieties, but enriches the reactivity zones by generating nitrogen molecular ions within the plasma jet. The complex competing reaction mechanisms among the radicals, ions, metastable atoms and UV photons lead to unusual etching patterns on the surfaces.

  8. Spacecraft Sterilization Using Non-Equilibrium Atmospheric Pressure Plasma

    Science.gov (United States)

    Cooper, Moogega; Vaze, Nachiket; Anderson, Shawn; Fridman, Gregory; Vasilets, Victor N.; Gutsol, Alexander; Tsapin, Alexander; Fridman, Alexander

    2007-01-01

    As a solution to chemically and thermally destructive sterilization methods currently used for spacecraft, non-equilibrium atmospheric pressure plasmas are used to treat surfaces inoculated with Bacillus subtilis and Deinococcus radiodurans. Evidence of significant morphological changes and reduction in viability due to plasma exposure will be presented, including a 4-log reduction of B. subtilis after 2 minutes of dielectric barrier discharge treatment.

  9. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... high. Causes Changes, either from genes or the environment, in the body’s normal functions may cause high ... in life. Environmental Causes of High Blood Pressure Environmental ... to constrict, or impact the renin-angiotensin-aldosterone system leading to high ...

  10. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... volumes and high blood pressure. Sympathetic Nervous System Activity The sympathetic nervous system has important functions in ... narrow in the kidneys, possibly causing kidney failure. Cognitive Changes: Research shows that over time, higher blood ...

  11. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... estrogen, and over-the-counter medicines such as cold relief medicines may cause this form of high blood ... blood pressure is more common in African American adults than in Caucasian or ...

  12. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... of physical activity Drinking too much alcohol Stress Family History A family history of high blood pressure ... sodium and salt intake, increase potassium, and eat foods that are heart healthy. Limiting Sodium and Salt ...

  13. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... because these other conditions change the way your body controls fluids, sodium, and hormones in ... lifestyle habits, and a family history of high blood pressure can increase your risk ...

  14. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... physical activity Drinking too much alcohol Stress Family History A family history of high blood pressure raises ... done in a health care provider’s office or clinic. To prepare for the test: Don’t drink ...

  15. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... associated with high blood pressure, some in the renal salt regulatory and renin-angiotensin-aldosterone pathways. However, ... include other medical conditions such as chronic kidney disease , sleep apnea , thyroid problems, or certain tumors. This ...

  16. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Font Size Accessible Search Form Search the NHLBI, use the drop down list to select: the entire ... primary high blood pressure. Health care providers can use this information to develop your treatment plan. Some ...

  17. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... of physical activity Drinking too much alcohol Stress Family History A family history of high blood pressure ... mass index (BMI). BMI measures your weight in relation to your height. To figure out your BMI, ...

  18. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Events About NHLBI About NHLBI Home Mission and Strategic Vision Leadership Scientific Divisions Operations and Administration Advisory ... health and can lower high blood pressure. Stress management techniques include: Being physically active Listening to music ...

  19. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... have this condition. ISH can cause as much harm as HBP in which both numbers are too ... for mother and baby. High blood pressure can harm the mother’s kidneys and other organs and can ...

  20. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... 5 ounces of wine 1½ ounces of liquor Managing and Coping With Stress Learning how to manage ... health and can lower high blood pressure. Stress management techniques include: Being physically active Listening to music ...

  1. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... harder and leading to high blood pressure. Medicines Prescription medicines such as asthma or hormone therapies, including ... health care provider before you start a new exercise plan. Ask him or her how much and ...

  2. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... physical health and can lower high blood pressure. Stress management techniques include: Being physically active Listening to music or focusing on something calm or peaceful Performing ...

  3. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... system activity , and blood vessel structure and function. Biology and High Blood Pressure Researchers continue to study ... and Your Heart U.S. Department of Health and Human Services' 2008 Physical Activity Guidelines for Americans Maintaining ...

  4. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... severity levels. Stages of High Blood Pressure in Adults Stages Systolic (top number) Diastolic (bottom number) Prehypertension ... that are heart healthy and low in fat, cholesterol, and salt. The DASH eating plan is a ...

  5. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... NHLBI About NHLBI Home Mission and Strategic Vision Leadership Scientific Divisions Operations and Administration Advisory Committees Budget ... in the blood vessels, causing the heart to work harder and leading to high blood pressure. Medicines ...

  6. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... physical activity Drinking too much alcohol Stress Family History A family history of high blood pressure raises the risk of ... Genetic causes of this condition are why family history is a risk factor for this condition. Screening ...

  7. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... volumes and high blood pressure. Sympathetic Nervous System Activity The sympathetic nervous system has important functions in ... Drinking excess amounts of alcohol Lack of physical activity Overweight and Obesity Research studies show that being ...

  8. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Tumblr. Share this page from the NHLBI on Twitter. Diagnosis of High Blood Pressure For most patients, ... events, activities, and resources at www.hearttruth.gov . Twitter Facebook YouTube Google+ SITE INDEX ACCESSIBILITY PRIVACY STATEMENT ...

  9. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... severity levels. Stages of High Blood Pressure in Adults Stages Systolic (top number) Diastolic (bottom number) Prehypertension ... lead to cognitive changes. Signs and symptoms include memory loss, difficulty finding words, and losing focus during ...

  10. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... system activity , and blood vessel structure and function. Biology and High Blood Pressure Researchers continue to study ... sodium and salt intake, increase potassium, and eat foods that are heart healthy. Limiting Sodium and Salt ...

  11. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Explore High Blood Pressure What Is... Other Names Causes Who Is at Risk Signs & Symptoms Diagnosis Treatments ... stress, which can occur during the medical appointment, causes white coat hypertension. Rate This Content: NEXT >> Updated: ...

  12. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... may contribute to high blood pressure. The angiotensin pathway and the immune system may stiffen small and ... the renal salt regulatory and renin-angiotensin-aldosterone pathways. However, these known genetic factors only account for ...

  13. High Blood Pressure and Pregnancy

    Science.gov (United States)

    Healthy Lifestyle Pregnancy week by week High blood pressure and pregnancy isn't necessarily a dangerous combination. Here's what you ... 2017 Original article: http://www.mayoclinic.org/healthy-lifestyle/pregnancy-week-by-week/in-depth/pregnancy/art-20046098 . ...

  14. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... control high blood pressure. Possible future treatments under investigation include new combination medicines, vaccines, and interventions aimed ... 2016 Bethesda, MD The NHLBI convened a working group of multidisciplinary researchers on June 10, 2016, to ...

  15. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... or Hispanic American adults. Compared with these ethnic groups, African Americans: Tend to get high blood pressure ... and Mexicans ate less sodium than other Hispanic groups in the study. All Hispanic Americans should follow ...

  16. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... ounces of liquor Managing and Coping With Stress Learning how to manage stress, relax, and cope with ... Future Treatments Scientists, doctors, and researchers continue to study the changes that cause high blood pressure, to ...

  17. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... severity levels. Stages of High Blood Pressure in Adults Stages Systolic (top number) Diastolic (bottom number) Prehypertension ... bleed. Signs and symptoms include vision changes or blindness. Heart Attack : When the flow of oxygen-rich ...

  18. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... 2016 Bethesda, MD The NHLBI convened a working group of multidisciplinary researchers on June 10, 2016, to share current scientific k... View all events on High Blood Pressure Building 31 ...

  19. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... lead to cognitive changes. Signs and symptoms include memory loss, difficulty finding words, and losing focus during ... high blood pressure. Treatment Plans Health care providers work with you to develop a treatment plan based ...

  20. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... NHLBI About NHLBI Home Mission and Strategic Vision Leadership Scientific Divisions Operations and Administration Advisory Committees Budget ... health and can lower high blood pressure. Stress management techniques include: Being physically active Listening to music ...

  1. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... physical activity Drinking too much alcohol Stress Family History A family history of high blood pressure raises ... and Digestive and Kidney Diseases) RELATED NEWS December 13, 2017 | Research Feature NIH’s SPRINT trial played a ...

  2. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... your risk for other related problems. Healthy Lifestyle Changes Healthy lifestyle habits can help you control high ... work with your health care team. Healthy Lifestyle Changes You can help control your blood pressure by ...

  3. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... and Strategic Vision Leadership Scientific Divisions Operations and Administration Advisory Committees Budget and Legislative Information Jobs and ... With DASH My Blood Pressure Wallet Card Other Resources Cigarette and Tobacco Facts (National Institute on Drug Abuse) High Blood ...

  4. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Events Spokespeople Email Alerts E-Newsletters About NHLBI Organization NHLBI Director Budget, Planning, & Legislative Advisory Committees Jobs Contact Us FAQs Home » Health Information for the Public » Health Topics » High Blood Pressure » ...

  5. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Obesity, Nutrition, and Physical Activity Population and Epidemiology Studies Women’s Health All Science A-Z Grants & Training ... Biology and High Blood Pressure Researchers continue to study how various changes in normal body functions cause ...

  6. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... volumes and high blood pressure. Sympathetic Nervous System Activity The sympathetic nervous system has important functions in ... plan closely and work with your health care team. Healthy Lifestyle Changes You can help control your ...

  7. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... the walls of the arteries as the heart pumps blood. High blood pressure, sometimes called hypertension, happens ... breath. Heart Failure : When the heart can’t pump enough blood to meet the body’s needs. Common ...

  8. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... these other conditions change the way your body controls fluids, sodium, and hormones in your ... lifestyle habits, and a family history of high blood pressure can increase your risk ...

  9. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... system activity , and blood vessel structure and function. Biology and High Blood Pressure Researchers continue to study ... Channel Blockers: Keep calcium from entering the muscle cells of your heart and blood vessels. This allows ...

  10. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... provider usually takes 2–3 readings at several medical appointments to diagnose high blood pressure. Using the ... Researchers believe stress, which can occur during the medical appointment, causes white coat hypertension. Rate This Content: ...

  11. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... to check readings at home or at other locations that have blood pressure equipment and to keep ... office compared with readings taken in any other location. Health care providers diagnose this type of high ...

  12. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Nutrition, and Physical Activity Population and Epidemiology Studies Women’s Health All Science A-Z Grants & Training Grants ... Before age 55, men are more likely than women to develop high blood pressure. After age 55, ...

  13. High Throughput Plasma Water Treatment

    Science.gov (United States)

    Mujovic, Selman; Foster, John

    2016-10-01

    The troublesome emergence of new classes of micro-pollutants, such as pharmaceuticals and endocrine disruptors, poses challenges for conventional water treatment systems. In an effort to address these contaminants and to support water reuse in drought stricken regions, new technologies must be introduced. The interaction of water with plasma rapidly mineralizes organics by inducing advanced oxidation in addition to other chemical, physical and radiative processes. The primary barrier to the implementation of plasma-based water treatment is process volume scale up. In this work, we investigate a potentially scalable, high throughput plasma water reactor that utilizes a packed bed dielectric barrier-like geometry to maximize the plasma-water interface. Here, the water serves as the dielectric medium. High-speed imaging and emission spectroscopy are used to characterize the reactor discharges. Changes in methylene blue concentration and basic water parameters are mapped as a function of plasma treatment time. Experimental results are compared to electrostatic and plasma chemistry computations, which will provide insight into the reactor's operation so that efficiency can be assessed. Supported by NSF (CBET 1336375).

  14. Differential coulometric oxidation following post column-switching high pressure liquid chromatography for fluorescence measurement of unmetabolized folic acid in human plasma.

    Science.gov (United States)

    Bailey, Steven W; Ayling, June E

    2013-11-08

    Although many countries have fortified their grain supplies with folic acid (FA) to decrease the incidence of neural tube defects, others have not due to concerns that this synthetic folate might have some adverse effects. Persistent unmetabolized FA has been found even in plasma from fasted subjects. To facilitate measurement of low levels of folic acid in human plasma, post-column coulometric oxidative cleavage was used to convert poorly fluorescent FA into a highly fluorescent compound determined to be 6-formyl-pterin. To minimize sample work-up and maximize recovery, column-switching HPLC transferred a window of eluate containing the FA from the first column (C8) onto a second column (phenyl-hexyl). The pH of two mobile phases were adjusted to be above and then below a pK of the FA α-carboxyl group, thus promoting separation from compounds coeluting from the C8-column. This permitted sample preparation using only a simple high recovery protein precipitation. Definitive identification of FA in human plasma was accomplished by duplicate injections of sample with the electrochemical voltage set above and below its half-potential. The LOD (S/N=3) was 0.10 nM. The intra- and inter-assay CV's were 2.3% and 5%, respectively. Comparison of these results with those obtained by HPLC/MS/MS with stable isotope internal standard showed a slope of 1.00 ± 0.019. This simple, sensitive, and repeatable assay facilitates a more thorough investigation of the response of various human populations to folic acid intake. Post-column differential coulometric electrochemistry can expand the variety of compounds amenable to fluorescence detection. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Electrokinetic high pressure hydraulic system

    Science.gov (United States)

    Paul, Phillip H.; Rakestraw, David J.

    2000-01-01

    A compact high pressure hydraulic pump having no moving mechanical parts for converting electric potential to hydraulic force. The electrokinetic pump, which can generate hydraulic pressures greater than 2500 psi, can be employed to compress a fluid, either liquid or gas, and manipulate fluid flow. The pump is particularly useful for capillary-base systems. By combining the electrokinetic pump with a housing having chambers separated by a flexible member, fluid flow, including high pressure fluids, is controlled by the application of an electric potential, that can vary with time.

  16. Numerical and Experimental Investigation of Electron Beam Air Plasma Properties at Moderate Pressure

    Science.gov (United States)

    Deng, Yongfeng; Tan, Yonghua; Han, Xianwei

    2014-01-01

    Large size of air plasma at near atmospheric pressure has specific effects in aerospace applications. In this paper, a two dimensional multi-fluid model coupled with Monte Carlo (MC) model is established, and some experiments were carried out to investigate the characteristics of electron beam air plasma at pressure of 100-170 Torr. Based on the model, the properties of electron beam air plasma are acquired. The electron density is of the order of 1016 m-3 and the longitudinal size can exceed 1.2 m. The profiles of charged particles demonstrate that the oxygen molecule is very important for air plasma and its elementary processes play a key role in plasma equilibrium processes. The potential is almost negative and a very low potential belt is observed at the edge of plasma acting as a protection shell. A series of experiments were carried out in a low pressure vacuum facility and the beam plasma densities were diagnosed. The experimental results demonstrate that electron density increased with the electron beam energy, and the relatively low pressure was favorable for gaining high density plasma. Hence in order to achieve high density and large size plasma, it requires the researchers to choose proper discharge parameters.

  17. Electrokinetic high pressure hydraulic system

    Science.gov (United States)

    Paul, Phillip H.; Rakestraw, David J.; Arnold, Don W.; Hencken, Kenneth R.; Schoeniger, Joseph S.; Neyer, David W.

    2001-01-01

    An electrokinetic high pressure hydraulic pump for manipulating fluids in capillary-based systems. The pump uses electro-osmotic flow to provide a high pressure hydraulic system, having no moving mechanical parts, for pumping and/or compressing fluids, for providing valve means and means for opening and closing valves, for controlling fluid flow rate, and manipulating fluid flow generally and in capillary-based systems (Microsystems), in particular. The compact nature of the inventive high pressure hydraulic pump provides the ability to construct a micro-scale or capillary-based HPLC system that fulfills the desire for small sample quantity, low solvent consumption, improved efficiency, the ability to run samples in parallel, and field portability. Control of pressure and solvent flow rate is achieved by controlling the voltage applied to an electrokinetic pump.

  18. Study of the low-pressure plasma effect on polypropylene nonwovens

    Science.gov (United States)

    López, R.; Boronat, T.; Pascual, M.; Calvo, O.; Balart, R.

    2010-06-01

    In this work we have used low-pressure plasma with a gas based on methane and oxygen mixture to improve wettability and durability of a PP nonwoven fabrics. The obtained results show good durability with the use of methane-oxygen plasma mixture gas. The effects of the plasma are similar to a plasmapolymerization process but in this case we obtain hydrophilic properties with high durability. The surface does not suffer important changes and the roughness of the material remains constant.

  19. Characterization of an atmospheric pressure air plasma source for polymer surface modification

    Science.gov (United States)

    Yang, Shujun; Tang, Jiansheng

    2013-10-01

    An atmospheric pressure air plasma source was generated through dielectric barrier discharge (DBD). It was used to modify polyethyleneterephthalate (PET) surfaces with very high throughput. An equivalent circuit model was used to calculate the peak average electron density. The emission spectrum from the plasma was taken and the main peaks in the spectrum were identified. The ozone density in the down plasma region was estimated by Absorption Spectroscopy. NSF and ARC-ODU

  20. Atmospheric-pressure dielectric barrier discharge (DBD) in air : plasma characterisation for skin therapy

    OpenAIRE

    Rajasekaran, Priyadarshini

    2011-01-01

    A pulsed atmospheric-pressure dielectric barrier discharge (DBD) device operating in air is investigated for medical applications such as for skin disinfection and promotion of wound healing. The device ignites plasma on objects of high capacitance such as the human body and with grounded electrodes. Plasma parameters such as electron density and electron distribution function are determined. Plasma chemical kinetics is simulated and the production of biologically-useful molecules...

  1. Intermolecular Interactions at high pressure

    DEFF Research Database (Denmark)

    Eikeland, Espen Zink

    2016-01-01

    In this project high-pressure single crystal X-ray diffraction has been combined with quantitative energy calculations to probe the energy landscape of three hydroquinone clathrates enclosing different guest molecules. The simplicity of the hydroquinone clathrate structures together with their st......In this project high-pressure single crystal X-ray diffraction has been combined with quantitative energy calculations to probe the energy landscape of three hydroquinone clathrates enclosing different guest molecules. The simplicity of the hydroquinone clathrate structures together....... High-pressure crystallography is the perfect method for studying intermolecular interactions, by forcing the molecules closer together. In all three studied hydroquinone clathrates, new pressure induced phase transitions have been discovered using a mixture of pentane and isopentane as the pressure...... transmitting medium. Through careful structural analysis combined with theoretical calculations, the structures of all the new high-pressure phases identified herein were determined. In the hydroquinone - methanol and hydroquinone - acetonitrile clathrate structures the phase transitions break the host...

  2. Low pressure plasmas and microstructuring technology

    CERN Document Server

    Franz, Gerhard

    2009-01-01

    A monograph that presents a perspective of gas discharge physics and its applications to various industries. It presents an overview of the different types to generate plasmas by DC discharges, capacitive and inductive radiofrequency coupling, helicon waves including electron cyclotron resonance, and ion beams.

  3. Starch Gelatinization Induced by High Hydrostatic Pressure

    National Research Council Canada - National Science Library

    Kazutaka YAMAMOTO

    2013-01-01

    .... Starch gelatinization can also be induced by high hydrostatic pressure. Requirements for pressure gelatinization may also differ depending on botanical origin of starch, pressure, water, and temperature...

  4. Effect of non-thermal atmospheric pressure plasma jet on human breast cancer cells

    Science.gov (United States)

    Mirpour, Shahriar; Nikkhah, Maryam; Pirouzmand, Somaye; Ghomi, Hamid Reza

    2012-10-01

    Nowadays, Non-thermal plasma enjoy a wide range of applications in biomedical fields such as Sterilization, Wound healing, Cancer treatment and etc. The aim of this paper is to study the effect of non-thermal atmospheric pressure plasma jet on breast cancer (MCF-7) cells. In this regard the effect of plasma on death of the cancer cells are explored experimentally. The plasma in this discharge is created by pulsed dc high voltage power supply with repetition rate of several tens of kilohertz which led to the inductively coupled plasma. The pure helium gas were used for formation of the plasma jet. MTT assay were used for quantification of death cells. The results showed that the cells death rate increase with plasma exposure time. This study confirm that plasma jet have significant effect on treatment of human breast cancer cells.

  5. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Entire Site Health Topics News & Resources Intramural Research Public Health Topics Education & Awareness Resources Contact The Health Information ... Contact Us FAQs Home » Health Information for the Public » Health Topics » High Blood Pressure » Diagnosis of High Blood ...

  6. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... happens because medicines can change the way your body controls fluid and salt balances, cause your blood vessels to constrict, or impact the renin-angiotensin-aldosterone system leading to high blood pressure. Other Medical Causes of High Blood ... these other conditions change the way your body controls fluids, sodium, and hormones in your blood, which leads ...

  7. Sterilization of Turmeric by Atmospheric Pressure Dielectric Barrier Discharge Plasma

    Science.gov (United States)

    Setareh, Salarieh; Davoud, Dorranian

    2013-11-01

    In this study atmospheric pressure dielectric barrier discharge (DBD) plasma has been employed for sterilizing dry turmeric powders. A 6 kV, 6 kHz frequency generator was used to generate plasma with Ar, Ar/O2, He, and He/O2 gases between the 5 mm gap of two quartz covered electrodes. The complete sterilization time of samples due to plasma treatment was measured. The most important contaminant of turmeric is bacillus subtilis. The results show that the shortest sterilization time of 15 min is achieved by exposing the samples to Ar/O2 plasma. Survival curves of samples are exponential functions of time and the addition of oxygen to plasma leads to a significant increase of the absolute value of time constant of the curves. Magnitudes of protein and DNA in treated samples were increased to a similar value for all samples. Taste, color, and solubility of samples were not changed after the plasma treatment.

  8. Helium atmospheric pressure plasma jets touching dielectric and metal surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Norberg, Seth A., E-mail: norbergs@umich.edu; Johnsen, Eric, E-mail: ejohnsen@umich.edu [Department of Mechanical Engineering, University of Michigan, 2350 Hayward Street, Ann Arbor, Michigan 48109-2125 (United States); Kushner, Mark J., E-mail: mjkush@umich.edu [Department of Electrical Engineering and Computer Science, University of Michigan, 1301 Beal Avenue, Ann Arbor, Michigan 48109-2122 (United States)

    2015-07-07

    Atmospheric pressure plasma jets (APPJs) are being investigated in the context plasma medicine and biotechnology applications, and surface functionalization. The composition of the surface being treated ranges from plastics, liquids, and biological tissue, to metals. The dielectric constant of these materials ranges from as low as 1.5 for plastics to near 80 for liquids, and essentially infinite for metals. The electrical properties of the surface are not independent variables as the permittivity of the material being treated has an effect on the dynamics of the incident APPJ. In this paper, results are discussed from a computational investigation of the interaction of an APPJ incident onto materials of varying permittivity, and their impact on the discharge dynamics of the plasma jet. The computer model used in this investigation solves Poisson's equation, transport equations for charged and neutral species, the electron energy equation, and the Navier-Stokes equations for the neutral gas flow. The APPJ is sustained in He/O{sub 2} = 99.8/0.2 flowing into humid air, and is directed onto dielectric surfaces in contact with ground with dielectric constants ranging from 2 to 80, and a grounded metal surface. Low values of relative permittivity encourage propagation of the electric field into the treated material and formation and propagation of a surface ionization wave. High values of relative permittivity promote the restrike of the ionization wave and the formation of a conduction channel between the plasma discharge and the treated surface. The distribution of space charge surrounding the APPJ is discussed.

  9. Free-floating atmospheric pressure ball plasmas

    Science.gov (United States)

    Wurden, G. A.; Ticos, C.; Wang, Z.; Wurden, C. J. V.

    2007-11-01

    A long-lived (0.3 second, 10-20 cm diameter) ball plasma floating in the air above a water surface has been formed and studied in the laboratory. A 0.4 - 1 mF capacitor is charged to 4-5 kV, and subsequently discharged (30-60 Amps, 20-50 msec duration) into central copper cathode held fixed just below the surface of a bucket of water (with a weak solution of various salts in distilled water, such as CuSO4 or CuCl2, LiCl or NaCl). An underwater ring anode completes the circuit. A bubble of hot vapor from the water surface rises up in the first few milliseconds, and changes from a mushroom cloud with stalk, to a detached quasi-spherical object, finally evolving into a vortex ring. The plasma consists of ionized water vapor, with positive salts and OH- radicals, as well as molecular species, and it completely excludes nitrogen or oxygen from the rising plasma structure. A fine boundary layer is visible in orange, in contrast to a green ball interior when using Cu/CuSO4, and filamentary structures are visible at late times. Finally, a whisp of smoke ring is observed as a residue. A variety of visible and infrared imaging (both video and still cameras) are used, along with 200-800 nm time & space resolved spectroscopy, to identify features of this laboratory analog to ball lightning. Possible applications include a windowless ball- plasma powered pulsed copper vapor laser operating at 510 nm.

  10. The High Fidelity Plasma Speaker

    Science.gov (United States)

    McGall, James

    2014-10-01

    A plasma speaker is a device that uses ionized gas as the driving source of sound production, rather than the traditional magnetic coil and membrane setup found on a standard speaker. Similar to how lightning produces sound, or even a small static shock, a plasma speaker uses a modulating electric arc between two electrodes to produce sound. An electric circuit is built that allows the variance of the high voltage electric potential to be controlled by a 3.5 mm standard audio headphone jack, allowing sound energy to be transferred from the plasma to the air by means of pulse width modulation. For my summer project I have built two different models of plasma speakers and am working on a third. The speaker benefits from having a nearly massless driver, and I hypothesize that it should show a response rate faster than that of a traditional speaker and a decreased impulse response while having the drawbacks of inefficiency and a low maximum decibel output. The speakers are currently being optimized with magnetic stabilization of the plasma and will be tested soon for impulse response, frequency generation, efficiency, and audio coloration. Bridges for SUCCESS Grant at Salisbury University under Ph.D. Matthew Bailey.

  11. High pressure neon arc lamp

    Science.gov (United States)

    Sze, Robert C.; Bigio, Irving J.

    2003-07-15

    A high pressure neon arc lamp and method of using the same for photodynamic therapies is provided. The high pressure neon arc lamp includes a housing that encloses a quantity of neon gas pressurized to about 500 Torr to about 22,000 Torr. At each end of the housing the lamp is connected by electrodes and wires to a pulse generator. The pulse generator generates an initial pulse voltage to breakdown the impedance of the neon gas. Then the pulse generator delivers a current through the neon gas to create an electrical arc that emits light having wavelengths from about 620 nanometers to about 645 nanometers. A method for activating a photosensitizer is provided. Initially, a photosensitizer is administered to a patient and allowed time to be absorbed into target cells. Then the high pressure neon arc lamp is used to illuminate the target cells with red light having wavelengths from about 620 nanometers to about 645 nanometers. The red light activates the photosensitizers to start a chain reaction that may involve oxygen free radicals to destroy the target cells. In this manner, a high pressure neon arc lamp that is inexpensive and efficiently generates red light useful in photodynamic therapy is provided.

  12. Characteristics of Cylindrical Microwave Plasma Source at Low Pressure

    Science.gov (United States)

    Park, Seungil; Youn, S.; Kim, S. B.; Yoo, S. J.

    2016-10-01

    A microwave plasma source with a cylindrical resonance cavity has been proposed to generate the plasma at low pressure. This plasma source consists of magnetron, waveguide, antenna, and cavity. The microwave generating device is a commercial magnetron with 1 kW output power at the frequency of 2.45 GHz. The microwave is transmitted through the rectangular waveguide with the whistle shape, and coupled to the cavity by the slot antenna. The resonant mode of the cylindrical cavity is the TE111 mode. The operating pressure is between 0.1 Torr and 0.3 Torr with the Argon and nitrogen gas. The electron temperature and electron number density of argon plasma were measured with the optical emission spectroscopy measurement. And Ar1s5 metastable density was measured using tunable diode laser absorption spectroscopy (TDLAS). The plasma diagnostic results of a cylindrical microwave plasma source would be described in this study. This work was supported by R&D Program of ``Plasma Advanced Technology for Agriculture and Food (Plasma Farming)'' through the National Fusion Research Institute of Korea (NFRI) funded by the Government funds.

  13. Reactive species in non-equilibrium atmospheric-pressure plasmas: Generation, transport, and biological effects

    Energy Technology Data Exchange (ETDEWEB)

    Lu, X., E-mail: luxinpei@hotmail.com [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); IFSA Collaborative Innovation Center, Shanghai Jiao Tong University, Shanghai 200240 (China); Naidis, G.V. [Joint Institute for High Temperatures, Russian Academy of Sciences, Moscow 125412 (Russian Federation); Laroussi, M. [Plasma Engineering & Medicine Institute, Old Dominion University, Norfolk, VA 23529 (United States); Reuter, S. [Leibniz Institute for Plasma Science and Technology, Felix-Hausdorff-Strasse 2, 17489 Greifswald (Germany); Graves, D.B. [Department of Chemical and Biomolecular Engineering, University of California, Berkeley, CA 94720 (United States); Ostrikov, K. [Institute for Future Environments, Queensland University of Technology, Brisbane, QLD 4000 (Australia); School of Physics, Chemistry, and Mechanical Engineering, Queensland University of Technology, Brisbane, QLD 4000 (Australia); Commonwealth Scientific and Industrial Research Organization, P.O.Box 218, Lindfield, NSW 2070 (Australia); School of Physics, The University of Sydney, Sydney, NSW 2006 (Australia)

    2016-05-04

    Non-equilibrium atmospheric-pressure plasmas have recently become a topical area of research owing to their diverse applications in health care and medicine, environmental remediation and pollution control, materials processing, electrochemistry, nanotechnology and other fields. This review focuses on the reactive electrons and ionic, atomic, molecular, and radical species that are produced in these plasmas and then transported from the point of generation to the point of interaction with the material, medium, living cells or tissues being processed. The most important mechanisms of generation and transport of the key species in the plasmas of atmospheric-pressure plasma jets and other non-equilibrium atmospheric-pressure plasmas are introduced and examined from the viewpoint of their applications in plasma hygiene and medicine and other relevant fields. Sophisticated high-precision, time-resolved plasma diagnostics approaches and techniques are presented and their applications to monitor the reactive species and plasma dynamics in the plasma jets and other discharges, both in the gas phase and during the plasma interaction with liquid media, are critically reviewed. The large amount of experimental data is supported by the theoretical models of reactive species generation and transport in the plasmas, surrounding gaseous environments, and plasma interaction with liquid media. These models are presented and their limitations are discussed. Special attention is paid to biological effects of the plasma-generated reactive oxygen and nitrogen (and some other) species in basic biological processes such as cell metabolism, proliferation, survival, etc. as well as plasma applications in bacterial inactivation, wound healing, cancer treatment and some others. Challenges and opportunities for theoretical and experimental research are discussed and the authors’ vision for the emerging convergence trends across several disciplines and application domains is presented to

  14. Surface processes of dust particles in low pressure plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Stoffels, E.; Stoffels, W.W.; Kersten, H.; Swinkels, G.H.P.M.; Kroesen, G.M.W. [Technische Univ. Eindhoven (Netherlands). Dept. of Physics

    2001-07-01

    This paper presents several aspects of applied dusty plasma research. New applications of dust particles are emerging; there is growing demand for particles with special properties, and for particle-seeded composite materials. Low-pressure plasmas offer a unique possibility of confinement, control and fine tailoring of particle properties. The role of low-pressure technology in surface modification (coating) of dust grains is discussed and illustrated with examples. Fundamental research related to industrial particle treatment aims at the understanding the surface chemistry of processing. More specifically, the nature of plasma-particle interactions must be resolved. Heat exchange and particle temperature, discussed in this paper, are of major interest in the applied dusty plasma studies. (orig.)

  15. Effect of Atmospheric Pressure Plasma Modification on Polyimide and Adhesive Joining with Titanium

    Science.gov (United States)

    Akram, M.; Jansen, K. M. B.; Ernst, L. J.; Bhowmik, S.; Ajeesh, G.; Ahmed, S.; Chakraborty, D.

    2015-10-01

    This investigation highlights the effect of surface modification on polyimide by atmospheric pressure plasma treatment with different exposure time. Surface modification of polymer by plasma treatment essentially creates physical and chemical changes such as cross-linking and formation of free radicals. It also forms oxygen functionalization in the form of polar groups on polymer surface, hence improving the wetting and adhesion properties. It is observed that surface energy of the polymer increases with increasing exposure time of atmospheric pressure plasma. However, prolonged exposure time of plasma results in deterioration of the surface layer of polyimide resulting in degradation and embrittlement. Scanning electron microscopy and atomic force microscopy analysis reveal that there is a considerable morphological change on the polymer surface due to atmospheric pressure plasma treatment. X-ray photo electron spectroscopy analysis reveals that the oxygen functionalities of polymer surface increases significantly when polyimide is exposed to atmospheric pressure plasma. Untreated and atmospheric pressure plasma-treated polyimide sheet are adhesive bonded by employing polyimide adhesive as well as with titanium substrate. Due to surface modification of polyimide, it is observed that there is a significant increase in lap shear tensile strength, and therefore, this technology is highly acceptable for aviation and space applications.

  16. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... which blood flows through blood vessels (arteries) at higher than normal pressures. Measuring Blood Pressure Blood pressure ... blood pressure are defined as having blood pressures higher than 120/80 mmHg. The following table outlines ...

  17. High Blood Pressure: Medicines to Help You

    Science.gov (United States)

    ... For Consumers Consumer Information by Audience For Women High Blood Pressure--Medicines to Help You Share Tweet Linkedin Pin ... Click here for the Color Version (PDF 533KB) High blood pressure is a serious illness. High blood pressure is ...

  18. Anxiety: A Cause of High Blood Pressure?

    Science.gov (United States)

    ... cause of high blood pressure? Can anxiety cause high blood pressure? Answers from Sheldon G. Sheps, M.D. Anxiety doesn't cause long-term high blood pressure (hypertension). But episodes of anxiety can cause dramatic, ...

  19. Atmospheric Pressure Plasma-Electrospin Hybrid Process for Protective Applications

    Science.gov (United States)

    Vitchuli Gangadharan, Narendiran

    2011-12-01

    -level aerosol chemical and biological threats. Polymer solution concentration, electrospinning voltage, and deposition areal density were varied to establish the relationship of processing-structure-filtration efficiency for electrospun fiber mats. A high barrier efficiency of greater than 99.5% was achieved on electrospun fiber mats without sacrificing air permeability and pressure drop. ii) Fabrication and Characterization of Multifunctional ZnO/Nylon 6 nanofibers ZnO/Nylon 6 nanofiber mats were prepared by an electrospinning-electrospraying hybrid process, The electrospinning of polymer solution and electrospraying of ZnO particles were carried out simultaneously such that the ZnO nanoparticles were dispersed on the surface of Nylon 6 nanofibers. The prepared ZnO/Nylon 6 nanofiber mats were tested for detoxifying characteristics against simulants of C-B agents. The results showed that ZnO/Nylon 6 functional nanofiber mats exhibited good detoxification action against paraoxon and have antibacterial efficiency over 99.99% against both the gram-negative E. coli and gram positive B. cereus bacteria. iii) Improving adhesion of electrospun nanofiber mat onto woven fabric by plasma pretreatment of substrate fabric and plasma-electrospinning hybrid process Electrospun nanofibers were deposited onto plasma-pretreated woven fabric to improve the adhesion. In addition, the plasma-electrospinning hybrid process was developed and used in which the nanofibers were subjected to in-situ plasma treatment during electrospinning. The effects of plasma treatement on substrate fabric and electrospun fibers were characterized by water contact angle test, XPS analyses. The improvement of nanofiber adhesive properties on fabric substrate was evaluated by peel test, flex resistance test and abrasion resistance test. The test results showed that the plasma treatment caused introduction of active chemical groups on substrate fabric and electrospun nanofibers. These active chemical assisted in possible

  20. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... NHLBI About NHLBI Home Mission and Strategic Vision Leadership Scientific Divisions Operations and Administration Advisory Committees Budget ... health and can lower high blood pressure. Stress management techniques include: ... guidelines now define hypertension as a systolic blood... View all news ...

  1. Vital Signs - High Blood Pressure

    Centers for Disease Control (CDC) Podcasts

    2012-10-02

    In the U.S., nearly one third of the adult population have high blood pressure, the leading risk factor for heart disease and stroke - two of the nation's leading causes of death.  Created: 10/2/2012 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 10/17/2012.

  2. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Trials Publications and Resources Health Education and Awareness The Science Science Home Blood Disorders and Blood Safety Sleep ... eating plan if you have high blood pressure. The DASH eating plan focuses on fruits, vegetables, whole grains, and other foods that are heart healthy ...

  3. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... at a higher risk for heart disease and type 2 diabetes. This risk may be high with a waist ... raise your blood pressure and triglyceride levels, a type of fat found in the ... have no more than one drink containing alcohol a day. One drink is: ...

  4. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... compared with readings taken in any other location. Health care providers diagnose this type of high blood pressure by reviewing readings in the office and readings taken anywhere else. Researchers believe stress, which can occur during the medical appointment, causes ...

  5. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Health Topics Education & Awareness Resources Contact The Health Information Center Health Professionals Systematic Evidence Reviews & Clinical Practice ... Advisory Committees Jobs Contact Us FAQs Home » Health Information for the Public » Health Topics » High Blood Pressure » ...

  6. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... condition is called isolated systolic hypertension (ISH). Many older adults have this condition. ISH can cause as much ... About 65 percent of Americans age 60 or older have high blood pressure. However, ... American adults than in Caucasian or Hispanic American adults. Compared ...

  7. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... cope with problems can improve your emotional and physical health and can lower high blood pressure. Stress management ... their experiences with clinical research. More Information Related Health ... Artery Disease Physical Activity and Your Heart Smoking and Your Heart ...

  8. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... and Your Heart U.S. Department of Health and Human Services' 2008 Physical Activity Guidelines for Americans Maintaining a Healthy Weight Maintaining a healthy weight can help you control high blood pressure and reduce your risk for ...

  9. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... obese . The terms “overweight” and “obese” refer to body weight that’s greater than what is considered healthy for a certain height. Gender Before age 55, men are more likely than women to develop high blood pressure. After age 55, ...

  10. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... you what you need to know about choosing foods that are lower in sodium. Try to eat no more than 2,300 mg sodium a day. If you have high blood pressure, you may need to restrict your sodium intake even more. Your health care provider ...

  11. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... 1½ ounces of liquor Managing and Coping With Stress Learning how to manage stress, relax, and cope with problems can improve your ... physical health and can lower high blood pressure. Stress management techniques include: Being physically active Listening to ...

  12. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Accessible Search Form Search the NHLBI, use the drop down list to select: the entire site, the Health Topics section only, or the News and Resources section. NHLBI ... for Health Professionals What Is High blood pressure is a common disease in which blood flows through blood vessels (arteries) ...

  13. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... this system cause high blood pressure. Blood Vessel Structure and Function Changes in the structure and function of small and large arteries may ... su presión arterial alta Hispanic Community Health Study Data Book In Brief: Your Guide to Lowering Your ...

  14. Transient evolution of solitary electron holes in low pressure laboratory plasma

    CERN Document Server

    Choudhary, Mangilal; Mukherjee, Subroto

    2015-01-01

    Solitary electrons holes (SEHs) are localized electrostatic positive potential structures in collisionless plasmas. These are vortex-like structures in the electron phase space. Its existence is cause of distortion of the electron distribution in the resonant region. These are explained theoretically first time by Schamel et.al [Phys. Scr. 20, 336 (1979) and Phys. Plasmas 19, 020501 (2012)]. Propagating solitary electron holes can also be formed in a laboratory plasma when a fast rising high positive voltage pulse is applied to a metallic electrode [Kar et. al., Phys. Plasmas 17, 102113 (2010)] immersed in a low pressure plasma. The temporal evolution of these structures can be studied by measuring the transient electron distribution function (EDF). In the present work, transient EDF is measured after formation of a solitary electron hole in nearly uniform, unmagnetized, and collisionless plasma for applied pulse width and, where and are applied pulse width and inverse of ion plasma frequency respectively. Fo...

  15. High Pressure Treatment in Foods

    Directory of Open Access Journals (Sweden)

    Edwin Fabian Torres Bello

    2014-08-01

    Full Text Available High hydrostatic pressure (HHP, a non-thermal technology, which typically uses water as a pressure transfer medium, is characterized by a minimal impact on food characteristics (sensory, nutritional, and functional. Today, this technology, present in many food companies, can effectively inactivate bacterial cells and many enzymes. All this makes HHP very attractive, with very good acceptance by consumers, who value the organoleptic characteristics of products processed by this non-thermal food preservation technology because they associate these products with fresh-like. On the other hand, this technology reduces the need for non-natural synthetic additives of low consumer acceptance.

  16. High-field/high-pressure ESR.

    Science.gov (United States)

    Sakurai, T; Okubo, S; Ohta, H

    2017-07-01

    We present a historical review of high-pressure ESR systems with emphasis on our recent development of a high-pressure, high-field, multi-frequency ESR system. Until 2000, the X-band system was almost established using a resonator filled with dielectric materials or a combination of the anvil cell and dielectric resonators. Recent developments have shifted from that in the low-frequency region, such as X-band, to that in multi-frequency region. High-pressure, high-field, multi-frequency ESR systems are classified into two types. First are the systems that use a vector network analyzer or a quasi-optical bridge, which have high sensitivity but a limited frequency region; the second are like our system, which has a very broad frequency region covering the THz region, but lower sensitivity. We will demonstrate the usefulness of our high-pressure ESR system, in addition to its experimental limitations. We also discuss the recent progress of our system and future plans. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... sensor, and a blood pressure cuff. With this equipment, they measure: Systolic Pressure: blood pressure when the ... or at other locations that have blood pressure equipment and to keep a written log of all ...

  18. Influence of pressure on ion energy distribution functions in EUV-induced hydrogen plasmas

    Science.gov (United States)

    van de Ven, T. H. M.; Reefman, P.; de Meijere, C. A.; Banine, V. Y.; Beckers, J.

    2016-09-01

    Next-generation lithography tools currently use Extreme Ultraviolet (EUV) radiation to create even smaller features on computer chips. The high energy photons (92 eV) induce a plasma in the low pressure background gas by photoionization. Industries have realized that these plasmas are of significant importance with respect to machine lifetime because impacting ions affect exposed surfaces. The mass resolved ion energy distribution function (IEDF) is therefore one of the main plasma parameters of interest. In this research an ion mass spectrometer is used to investigate IEDFs of ions impacting on surfaces in EUV-induced plasmas. EUV radiation is focused into a vessel with a low pressure hydrogen environment. Here, photoionization creates free electrons with energies up to 76 eV, which further ionize the background gas. The influence of the pressure on plasma composition and IEDFs has been investigated in the range 0.1-10 Pa. In general the ion fluxes towards the surface increase with pressure. However, above 5 Pa the flux of H2+ is not affected by the increase in pressure due to the balance between the creation of H2+ and the conversion of H2+ to H3+. These results will be used to benchmark plasma scaling models and verify numerical simulations.

  19. Generation of uniform atmospheric pressure argon glow plasma by ...

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 80; Issue 3. Generation of uniform atmospheric pressure argon glow plasma by dielectric barrier discharge. Raju Bhai Tyata Deepak Prasad Subedi Rajendra Shrestha Chiow San Wong. Research Articles Volume 80 Issue 3 March 2013 pp 507-517 ...

  20. Application of atmospheric pressure plasma on polyethylene for increased prosthesis adhesion

    Energy Technology Data Exchange (ETDEWEB)

    Van Vrekhem, S., E-mail: stijn.vanvrekhem@ugent.be [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering and Architecture, Ghent University, Sint-Pietersnieuwstraat 41 B4, 9000 Ghent (Belgium); Cools, P. [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering and Architecture, Ghent University, Sint-Pietersnieuwstraat 41 B4, 9000 Ghent (Belgium); Declercq, H. [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering and Architecture, Ghent University, Sint-Pietersnieuwstraat 41 B4, 9000 Ghent (Belgium); Tissue Engineering Group, Department of Basic Medical Sciences, Faculty of Medicine and Health Sciences, Ghent University, De Pintelaan 185 6B3, 9000 Ghent (Belgium); Van Tongel, A. [Department of Orthopaedic Surgery and Traumatology, Ghent University Hospital, De Pintelaan 185 13K12, 9000 Ghent (Belgium); Vercruysse, C.; Cornelissen, M. [Tissue Engineering Group, Department of Basic Medical Sciences, Faculty of Medicine and Health Sciences, Ghent University, De Pintelaan 185 6B3, 9000 Ghent (Belgium); De Geyter, N.; Morent, R. [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering and Architecture, Ghent University, Sint-Pietersnieuwstraat 41 B4, 9000 Ghent (Belgium)

    2015-12-01

    Biopolymers are often subjected to surface modification in order to improve their surface characteristics. The goal of this study is to show the use of plasma technology to enhance the adhesion of ultra-high molecular weight polyethylene (UHMWPE) shoulder prostheses. Two different plasma techniques (low pressure plasma activation and atmospheric pressure plasma polymerization) are performed on UHMWPE to increase the adhesion between (1) the polymer and polymethylmethacrylate (PMMA) bone cement and (2) the polymer and osteoblast cells. Both techniques are performed using a dielectric barrier discharge (DBD). A previous paper showed that low pressure plasma activation of UHMWPE results in the incorporation of oxygen-containing functional groups, which leads to an increased surface wettability. Atmospheric pressure plasma polymerization of methylmethacrylate (MMA) on UHMWPE results in a PMMA-like coating, which could be deposited with a high degree of control of chemical composition and layer thickness. The thin film also proved to be relatively stable upon incubation in a phosphate buffer solution (PBS). This paper discusses the next stage of the study, which includes testing the adhesion of the plasma-activated and plasma-polymerized samples to bone cement through pull-out tests and testing the cell adhesion and proliferation on the samples. In order to perform the pull-out tests, all samples were cut to standard dimensions and fixed in bone cement in a reproducible way with a sample holder specially designed for this purpose. The cell adhesion and proliferation were tested by means of an MTS assay and live/dead staining after culturing MC3T3 osteoblast cells on UHMWPE samples. The results show that both plasma activation and plasma polymerization significantly improve the adhesion to bone cement and enhance cell adhesion and proliferation. In conclusion, it can be stated that the use of plasma technology can lead to an implant with improved quality and a subsequent

  1. High pressure effects on fruits and vegetables

    NARCIS (Netherlands)

    Timmermans, R.A.H.; Matser, A.M.

    2016-01-01

    The chapter provides an overview on different high pressure based treatments (high pressure pasteurization, blanching, pressure-assisted thermal processing, pressure-shift freezing and thawing) available for the preservation of fruits and vegetable products and extending their shelf life. Pressure

  2. Diagnostics of atmospheric pressure capillary DBD oxygen plasma jet

    CERN Document Server

    Roy, N C; Pramanik, B K

    2015-01-01

    Atmospheric pressure capillary dielectric barrier oxygen discharge plasma jet is developed to generate non-thermal plasma using unipolar positive pulse power supply. Both optical and electrical techniques are used to investigate the characteristics of the produced plasma as function of applied voltage and gas flow rate. Analytical results obtained from the optical emission spectroscopic data reveal the gas temperature, rotational temperature, excitation temperature and electron density. Gas temperature and rotational temperature are found to decrease with increasing oxygen flow rate but increase linearly with applied voltage. It is exposed that the electron density is boosting up with enhanced applied voltage and oxygen flow rate, while the electron excitation temperature is reducing with rising oxygen flow rate. Electrical characterization demonstrates that the discharge frequency is falling with flow rate but increasing with voltage. The produced plasma is applied preliminarily to study the inactivation yie...

  3. Generation of large-scale, barrier-free diffuse plasmas in air at atmospheric pressure using array wire electrodes and nanosecond high-voltage pulses

    Science.gov (United States)

    Teng, Yun; Li, Lee; Liu, Yun-Long; Liu, Lun; Liu, Minghai

    2014-10-01

    This paper introduces a method to generate large-scale diffuse plasmas by using a repetition nanosecond pulse generator and a parallel array wire-electrode configuration. We investigated barrier-free diffuse plasmas produced in the open air in parallel and cross-parallel array line-line electrode configurations. We found that, when the distance between the wire-electrode pair is small, the discharges were almost extinguished. Also, glow-like diffuse plasmas with little discharge weakening were obtained in an appropriate range of line-line distances and with a cathode-grounding cross-electrode configuration. As an example, we produced a large-scale, stable diffuse plasma with volumes as large as 18 × 15 × 15 cm3, and this discharge region can be further expanded. Additionally, using optical and electrical measurements, we showed that the electron temperature was higher than the gas temperature, which was almost the same as room temperature. Also, an array of electrode configuration with more wire electrodes had helped to prevent the transition from diffuse discharge to arc discharge. Comparing the current waveforms of configurations with 1 cell and 9 cells, we found that adding cells significantly increased the conduction current and the electrical energy delivered in the electrode gaps.

  4. Surface Modification by Atmospheric Pressure Plasma for Improved Bonding

    Science.gov (United States)

    Williams, Thomas Scott

    An atmospheric pressure plasma source operating at temperatures below 150?C and fed with 1.0-3.0 volume% oxygen in helium was used to activate the surfaces of the native oxide on silicon, carbon-fiber reinforced epoxy composite, stainless steel type 410, and aluminum alloy 2024. Helium and oxygen were passed through the plasma source, whereby ionization occurred and ˜10 16 cm-3 oxygen atoms, ˜1015 cm -3 ozone molecules and ˜1016 cm-3 metastable oxygen molecules (O21Deltag) were generated. The plasma afterglow was directed onto the substrate material located 4 mm downstream. Surface properties of the plasma treated materials have been investigated using water contact angle (WCA), atomic force microscopy (AFM), infrared spectroscopy (IR), and x-ray photoelectron spectroscopy (XPS). The work presented herein establishes atmospheric-pressure plasma as a surface preparation technique that is well suited for surface activation and enhanced adhesive bond strength in a variety of materials. Atmospheric plasma activation presents an environmentally friendly alternative to wet chemical and abrasive methods of surface preparation. Attenuated total internal reflection infrared spectroscopy was used to study the aging mechanism of the native oxide on silicon. During storage at ambient conditions, the water contact angle of a clean surface increased from peel ply. After oxygen plasma activation and joining the materials together with epoxy, one observes 100% cohesive failure within the cured film adhesive. Depending on the material, the lap shear strength can be increased several fold over that achieved by either solvent wiping or abrasion. The trends in adhesion with plasma exposure time do not correlate well with surface wetting or roughness; instead they correlate with the fraction of the polymer surface sites that are converted into carboxylic acid groups.

  5. Sheath and bulk expansion induced by RF bias in atmospheric pressure microwave plasma

    Science.gov (United States)

    Lee, Jimo; Nam, Woojin; Lee, Jae Koo; Yun, Gunsu

    2017-10-01

    A large axial volume expansion of microwave-driven plasma at atmospheric pressure is achieved by applying a low power radio frequency (RF) bias at an axial location well isolated from the original plasma bulk. The evolution of the plasma plume visualized by high speed ICCD imaging suggest that the free electrons drifting toward the bias electrode cause the prodigious expansion of the sheath, creating a stable plasma stream channel between the microwave and the RF electrodes. For argon plasma in ambient air, enhanced emissions of OH and N2 spectral lines are measured in the extended plume region, supporting the acceleration of electrons and subsequent generation of radical species. The coupling of RF bias with microwave provides an efficient way of enlarging the plasma volume and enhancing the production of radicals. Work supported by the National Research Foundation of Korea under BK21+ program and Grant No. 2015R1D1A1A01061556 (Ministry of Education).

  6. High pressure processing of meat

    DEFF Research Database (Denmark)

    Grossi, Alberto; Christensen, Mette; Ertbjerg, Per

    Abstract Background: The research of high pressure (HP) processing of meat based foods needs to address how pressure affects protein interactions, aggregation and/or gelation. The understanding of the gel forming properties of myofibrillar components is fundamental for the development of muscle...... based products (Chapleau et al., 2004;Colmenero, 2002). Object: The aim was to study the rheological properties of pork meat emulsion exposed to HP and the effect of HP on the aggregation state of myofibrillar proteins. To address the role of cathepsin in myofibrillar protein degradation the changes...... in the myofibrillar protein pattern and HP-induced change in activity of cathepsin B and L were investigated. Results: In this study we showed that HP treatment of pork meat emulsion, ranging from 0.1 to 800 MPa, induced protein gel formation as shown by the increased Young’s modulus (Fig.1). Analysis of SDS...

  7. Adhesion improvement of fibres by continuous plasma treatment at atmospheric pressure

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Løgstrup Andersen, Tom; Sørensen, Bent F.

    2013-01-01

    Carbon fibres and ultra-high-molecular-weight polyethylene (UHMWPE) fibres were continuously treated by a dielectric barrier discharge plasma at atmospheric pressure for adhesion improvement with epoxy resins. The plasma treatment improved wettability, increased the oxygen containing polar...... functional groups at the surface, and subsequently improved adhesion to the epoxy and fracture resistance of epoxy composites. Hansen solubility parameters (HSP), quantitatively describing physical interactions among molecules, were measured for the UHMWPE fibre surfaces. The result identifies two distinct...

  8. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... nervous system has important functions in blood pressure regulation, including heart rate, blood pressure, and breathing rate. ... EVENT The Role of Microbiota in Blood Pressure Regulation Executive Summary June 10, 2016 Bethesda, MD The ...

  9. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... your blood pressure returns to your normal baseline range. Blood pressure normally rises with age and body ... 160 or higher OR 100 or higher The ranges in the table are blood pressure guides for ...

  10. Compact atmospheric pressure plasma self-resonant drive circuits

    Science.gov (United States)

    Law, V. J.; Anghel, S. D.

    2012-02-01

    This paper reports on compact solid-state self-resonant drive circuits that are specifically designed to drive an atmospheric pressure plasma jet and a parallel-plate dielectric barrier discharge of small volume (0.5 cm3). The atmospheric pressure plasma (APP) device can be operated with helium, argon or a mixture of both. Equivalent electrical models of the self-resonant drive circuits and discharge are developed and used to estimate the plasma impedance, plasma power density, current density or electron number density of three APP devices. These parameters and the kinetic gas temperature are dependent on the self-resonant frequency of the APP device. For a fixed switching frequency and APP device geometry, the plasma parameters are controlled by adjusting the dc voltage at the primary coil and the gas flow rate. The resonant frequency is controlled by the selection of the switching power transistor and means of step-up voltage transformation (ferrite core, flyback transformer, or Tesla coil). The flyback transformer operates in the tens of kHz, the ferrite core in the hundreds of kHz and Tesla coil in the MHz range. Embedded within this work is the principle of frequency pulling which is exemplified in the flyback transformer circuit that utilizes a pickup coil for feedback control of the switching frequency.

  11. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... System Activity The sympathetic nervous system has important functions in blood pressure regulation, including heart rate, blood pressure, and breathing rate. Researchers are ...

  12. Effect of feed-gas humidity on nitrogen atmospheric-pressure plasma jet for biological applications.

    Science.gov (United States)

    Stephan, Karl D; McLean, Robert J C; DeLeon, Gian; Melnikov, Vadim

    2016-11-14

    We investigate the effect of feed-gas humidity on the oxidative properties of an atmospheric-pressure plasma jet using nitrogen gas. Plasma jets operating at atmospheric pressure are finding uses in medical and biological settings for sterilization and other applications involving oxidative stress applied to organisms. Most jets use noble gases, but some researchers use less expensive nitrogen gas. The feed-gas water content (humidity) has been found to influence the performance of noble-gas plasma jets, but has not yet been systematically investigated for jets using nitrogen gas. Low-humidity and high-humidity feed gases were used in a nitrogen plasma jet, and the oxidation effect of the jet was measured quantitatively using a chemical dosimeter known as FBX (ferrous sulfate-benzoic acid-xylenol orange). The plasma jet using high humidity was found to have about ten times the oxidation effect of the low-humidity jet, as measured by comparison with the addition of measured amounts of hydrogen peroxide to the FBX dosimeter. Atmospheric-pressure plasma jets using nitrogen as a feed gas have a greater oxidizing effect with a high level of humidity added to the feed gas.

  13. Atmospheric pressure plasma jet's characterization and surface wettability driven by neon transformer

    Science.gov (United States)

    Elfa, R. R.; Nafarizal, N.; Ahmad, M. K.; Sahdan, M. Z.; Soon, C. F.

    2017-03-01

    Atmospheric pressure plasma driven by Neon transformer power supply argon is presented in this paper. Atmospheric pressure plasma system has attracted researcher interest over low pressure plasma as it provides a flexibility process, cost-efficient, portable device and vacuum-free device. Besides, another golden key of this system is the wide promising application in the field of work cover from industrial and engineering to medical. However, there are still numbers of fundamental investigation that are necessary such as device configuration, gas configuration and its effect. Dielectric barrier discharge which is also known as atmospheric pressure plasma discharge is created when there is gas ionization process occur which enhance the movement of atom and electron and provide energetic particles. These energetic particles can provide modification and cleaning property to the sample surface due to the bombardment of the high reactive ion and radicals to the sample surface. In order to develop atmospheric pressure plasma discharge, a high voltage and high frequency power supply is needed. In this work, we used a neon transformer power supply as the power supply. The flow of the Ar is feed into 10 mm cylinder quartz tube with different treatment time in order to investigate the effect of the plasma discharge. The analysis of each treatment time is presented by optical emission spectroscopy (OES) and water contact angle (WCA) measurement. The increase of gas treatment time shows increases intensity of reactive Ar and reduces the angle of water droplets in water contact angle. Treatment time of 20 s microslide glass surface shows that the plasma needle discharges have modified the sample surface from hydrophilic surface to superhydrophilic surface. Thus, this leads to another interesting application in reducing sample surface adhesion to optimize productivity in the industry of paintings, semiconductor and more.

  14. Thermodynamic and Transport Properties of Real Air Plasma in Wide Range of Temperature and Pressure

    Science.gov (United States)

    Wang, Chunlin; Wu, Yi; Chen, Zhexin; Yang, Fei; Feng, Ying; Rong, Mingzhe; Zhang, Hantian

    2016-07-01

    Air plasma has been widely applied in industrial manufacture. In this paper, both dry and humid air plasmas' thermodynamic and transport properties are calculated in temperature 300-100000 K and pressure 0.1-100 atm. To build a more precise model of real air plasma, over 70 species are considered for composition. Two different methods, the Gibbs free energy minimization method and the mass action law method, are used to determinate the composition of the air plasma in a different temperature range. For the transport coefficients, the simplified Chapman-Enskog method developed by Devoto has been applied using the most recent collision integrals. It is found that the presence of CO2 has almost no effect on the properties of air plasma. The influence of H2O can be ignored except in low pressure air plasma, in which the saturated vapor pressure is relatively high. The results will serve as credible inputs for computational simulation of air plasma. supported by the National Key Basic Research Program of China (973 Program)(No. 2015CB251002), National Natural Science Foundation of China (Nos. 51521065, 51577145), the Science and Technology Project Funds of the Grid State Corporation (SGTYHT/13-JS-177), the Fundamental Research Funds for the Central Universities, and State Grid Corporation Project (GY71-14-004)

  15. Carbon nanostructures under high pressure

    CERN Document Server

    Sundqvist, B

    2002-01-01

    Results from recent high-pressure experiments in the field of fullerenes are briefly reviewed. In particular, new results on one-, two- and three-dimensional polymerized C sub 6 sub 0 and C sub 7 sub 0 are discussed. Results discussed include the first synthesis of a well defined, one-dimensional polymer based on C sub 7 sub 0 , transformations from two-dimensional (2D) to three-dimensional phases in C sub 6 sub 0 , and doping of 2D C sub 6 sub 0 polymers.

  16. Study of Volumetrically Heated Ultra-High Energy Density Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Rocca, Jorge J. [Colorado State Univ., Fort Collins, CO (United States)

    2016-10-27

    Heating dense matter to millions of degrees is important for applications, but requires complex and expensive methods. The major goal of the project was to demonstrate using a compact laser the creation of a new ultra-high energy density plasma regime characterized by simultaneous extremely high temperature and high density, and to study it combining experimental measurements and advanced simulations. We have demonstrated that trapping of intense femtosecond laser pulses deep within ordered nanowire arrays can heat near solid density matter into a new ultra hot plasma regime. Extreme electron densities, and temperatures of several tens of million degrees were achieved using laser pulses of only 0.5 J energy from a compact laser. Our x-ray spectra and simulations showed that extremely highly ionized plasma volumes several micrometers in depth are generated by irradiation of gold and Nickel nanowire arrays with femtosecond laser pulses of relativistic intensities. We obtained extraordinarily high degrees of ionization (e.g. we peeled 52 electrons from gold atoms, and up to 26 electrons from nickel atoms). In the process we generated Gigabar pressures only exceeded in the central hot spot of highly compressed thermonuclear fusion plasmas.. The plasma created after the dissolved wires expand, collide, and thermalize, is computed to have a thermal energy density of 0.3 GJ cm-3 and a pressure of 1-2 Gigabar. These are pressures only exceeded in highly compressed thermonuclear fusion plasmas. Scaling these results to higher laser intensities promises to create plasmas with temperatures and pressures exceeding those in the center of the sun.

  17. Suppressed ion-scale turbulence in a hot highplasma.

    Science.gov (United States)

    Schmitz, L; Fulton, D P; Ruskov, E; Lau, C; Deng, B H; Tajima, T; Binderbauer, M W; Holod, I; Lin, Z; Gota, H; Tuszewski, M; Dettrick, S A; Steinhauer, L C

    2016-12-21

    An economic magnetic fusion reactor favours a high ratio of plasma kinetic pressure to magnetic pressure in a well-confined, hot plasma with low thermal losses across the confining magnetic field. Field-reversed configuration (FRC) plasmas are potentially attractive as a reactor concept, achieving high plasma pressure in a simple axisymmetric geometry. Here, we show that FRC plasmas have unique, beneficial microstability properties that differ from typical regimes in toroidal confinement devices. Ion-scale fluctuations are found to be absent or strongly suppressed in the plasma core, mainly due to the large FRC ion orbits, resulting in near-classical thermal ion confinement. In the surrounding boundary layer plasma, ion- and electron-scale turbulence is observed once a critical pressure gradient is exceeded. The critical gradient increases in the presence of sheared plasma flow induced via electrostatic biasing, opening the prospect of active boundary and transport control in view of reactor requirements.

  18. Avalanches driven by pressure gradients in a magnetized plasma

    Science.gov (United States)

    Van Compernolle, B.; Morales, G. J.

    2017-11-01

    The results are presented for a basic heat transport experiment involving an off-axis heat source in which avalanche events occur. The configuration consists of a long, hollow, cylindrical region of elevated electron temperature embedded in a colder plasma, and far from the device walls [Van Compernolle et al. Phys. Rev. E 91, 031102(R) (2015)]. The avalanche events are identified as sudden rearrangements of the pressure profile following the growth of fluctuations from ambient noise. The intermittent collapses of the plasma pressure profile are associated with unstable drift-Alfvén waves and exhibit both radial and poloidal dynamics. After each collapse, the plasma enters a quiescent phase in which the pressure profile slowly recovers and steepens until a threshold is exceeded, and the process repeats. The use of reference probes as time markers allows for the visualization of the 2D spatio-temporal evolution of the avalanche events. Avalanches are observed only for a limited combination of heating powers and magnetic fields. At higher heating powers, the system transits from the avalanche regime into a regime dominated by sustained drift-Alfvén wave activity. This manuscript focuses on new results that illustrate the individual contributions to the avalanche process from density and temperature gradients in the presence of zero-order, sheared flows.

  19. Zero voltage switching driver and flyback transformer for generation of atmospheric pressure plasma jet

    Science.gov (United States)

    Zin, Rosnah Mohd; Soon, Chin Fhong; Sani, Mohd Zuhri Ab; Rizon, Elfa Rizan; Tee, Kian Sek; Ahmad, Mohd Khairul; Ahmad, Nabihah@Nornabihah; Jubadi, Warsuzarina Mat; Nayan, Nafarizal

    2017-09-01

    There are increasing interests in the application of cold atmospheric plasma device for the application in surface science and medical field. Numerous studies focused on the effects of plasma emission onto living organisms. This report presents the application of a power driver circuit for induction of cold atmospheric plasma (CAP). The system consists of a resonant inverter of Zero Voltage Switching (ZVS) circuit powered by a 12Vdc input voltage which is coupled to a flyback transformer in generation of high voltage up to 24.5 kV. The output voltage from the ZVS driver and flyback transformer to the plasma torch (quartz tube) was determined using Falstad circuit simulation. The simulation on the waveforms generated from the ZVS circuit correlated well with the actual voltage measurement at the output of the ZVS circuit. The peak voltage dropped across a parallel capacitor coupled to the flyback transformer is approximately 36 V. The atmospheric pressure plasma jet (APPJ) purged with Argon gas at a flow rate of 50 l/min was exposed to a leaf for 5 seconds. This created pin holes in the exposed area of the leaf indicating high temperature was induced at the focused spot of the plasma. An atmospheric pressure plasma jet (APPJ) system has been developed for with potential application in destructive medicine.

  20. On uniform plasma generation for the large area plasma processing in intermediate pressures

    Science.gov (United States)

    Kim, Hyun Jun; Hwang, Hye-Ju; Kim, Dong Hwan; Cho, Jeong Hee; Chae, Hee Sun; Chung, Chin-Wook

    2015-04-01

    Radial plasma discharge characteristics in the range of 450 mm were studied in a dual inductively coupled plasma (ICP) source, which consisted of a helical ICP and the side type ferrite ICPs. Since the energy relaxation length is shorter than the distance between each of the ferrite ICPs in an intermediate pressure (600 mTorr), local difference in the plasma ignition along the antenna position were observed. In addition, large voltage drop in the discharge of the ferrite ICPs causes an increase in the displacement current to the plasma, and separate discharge mode (E and H mode) according to the antenna position was observed. This results in non-uniform plasma distribution. For the improvement in the discharge of the ferrite ICPs, a capacitor which is placed between the ends of antenna and the ground is adjusted to minimize the displacement current to the plasma. As a result, coincident transitions from E to H mode were observed along the antenna position, and radially concave density profile (edge focused) was measured. For the uniform density distribution, a helical ICP, which located at the center of the discharge chamber, was simultaneously discharged with the ferrite ICPs. Due to the plasma potential variation through the simultaneous discharge of helical ICP and ferrite ICPs, uniform radial distribution in both plasma density and electron temperature are achieved.

  1. Fast low-temperature plasma reduction of monolayer graphene oxide at atmospheric pressure

    Science.gov (United States)

    Bodik, Michal; Zahoranova, Anna; Micusik, Matej; Bugarova, Nikola; Spitalsky, Zdenko; Omastova, Maria; Majkova, Eva; Jergel, Matej; Siffalovic, Peter

    2017-04-01

    We report on an ultrafast plasma-based graphene oxide reduction method superior to conventional vacuum thermal annealing and/or chemical reduction. The method is based on the effect of non-equilibrium atmospheric-pressure plasma generated by the diffuse coplanar surface barrier discharge in proximity of the graphene oxide layer. As the reduction time is in the order of seconds, the presented method is applicable to the large-scale production of reduced graphene oxide layers. The short reduction times are achieved by the high-volume power density of plasma, which is of the order of 100 W cm-3. Monolayers of graphene oxide on silicon substrate were prepared by a modified Langmuir-Schaefer method and the efficient and rapid reduction by methane and/or hydrogen plasma was demonstrated. The best results were obtained for the graphene oxide reduction in hydrogen plasma, as verified by x-ray photoelectron spectroscopy and Raman spectroscopy.

  2. Modeling of diffusive plasmas in local thermodynamic equilibrium with integral constraints: application to mercury-free high pressure discharge lamp mixtures

    Science.gov (United States)

    Janssen, J. F. J.; Suijker, J. L. G.; Peerenboom, K. S. C.; van Dijk, J.

    2017-03-01

    The mercury free lamp model previously discussed in Gnybida et al (2014 J. Phys. D: Appl. Phys. 47 125201) did not account for self-consistent diffusion and only included two molecular transitions. In this paper we apply, for the first time, a self-consistent diffusion algorithm that features (1) species/mass conservation up to machine accuracy and (2) an arbitrary mix of integral (total mass) and local (cold spot) constraints on the composition. Another advantage of this model is that the total pressure of the gas is calculated self consistently. Therefore, the usage of a predetermined pressure is no longer required. Additionally, the number of association processes has been increased from 2 to 6. The population as a function of interatomic separation determines the spectrum of the emitted continuum radiation. Previously, this population was calculated using the limit of low densities. In this work an expression is used that removes this limitation. The result of these improvements is that the agreement between the simulated and measured spectra has improved considerably.

  3. Trends in surface engineering of biomaterials: atmospheric pressure plasma deposition of coatings for biomedical applications

    Science.gov (United States)

    da Ponte, G.; Sardella, E.; Fanelli, F.; D'Agostino, R.; Favia, P.

    2011-11-01

    Cold plasma processes for surface engineering of biomaterials and biomedical devices are traditionally performed at low pressure; more and more, though, surface modification plasma processes at atmospheric pressure are also gaining popularity. This short review is aimed to list briefly atmospheric pressure plasma processes reported, in the last decade, for adapting the surface of materials to the best interactions with cells, bacteria and biomolecules.

  4. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... or hormone therapies, including birth control pills and estrogen, and over-the-counter medicines such as cold ... pressure. Medicines to lower blood pressure include: Diuretics (Water or Fluid Pills): Flush excess sodium from your ...

  5. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... blood pressure test is easy and painless and can be done in a health care provider’s office ... severity of your blood pressure, he or she can order additional tests to determine if your blood ...

  6. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... blood pressure, health care providers recommend that you limit sodium and salt intake, increase potassium, and eat ... manage your blood pressure. You should try to limit the amount of sodium that you eat. This ...

  7. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... blood pressure readings the same way for children, teens, and adults. They use a gauge, stethoscope or ... that are considered normal for babies, while older teens have numbers similar to adults. Abnormal Blood Pressure ...

  8. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... blood pressure medicines, sometimes in one combined pill. Beta Blockers: Help your heart beat slower and with less ... freely, causing blood pressure to go down. Alpha-Beta Blockers: Reduce nerve impulses the same way alpha blockers ...

  9. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... track blood pressure readings over a period of time, the health care provider may ask you to ... the office on different days and at different times to take your blood pressure. The health care ...

  10. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... term serious illnesses. People with diabetes or chronic kidney disease should keep their blood pressure below 130/80 ... pressure include other medical conditions such as chronic kidney disease , sleep apnea , thyroid problems, or certain tumors. This ...

  11. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Signs and symptoms include memory loss, difficulty finding words, and losing focus during conversations. Eye Damage: When ... pressure. Medicines to lower blood pressure include: Diuretics (Water or Fluid Pills): Flush excess sodium from your ...

  12. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... the body’s salt balance by retaining sodium and water and excreting potassium. Imbalances in this kidney function ... pressure. Medicines to lower blood pressure include: Diuretics (Water or Fluid Pills): Flush excess sodium from your ...

  13. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... narrow, which can lower your blood pressure. Calcium Channel Blockers: Keep calcium from entering the muscle cells ... talk with your health care provider and take steps to control your blood pressure by making healthy ...

  14. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... families. Genetic causes of this condition are why family history is a risk factor for ... blood pressure regularly. Children should have their blood pressure checked starting at ...

  15. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... talk with your health care provider and take steps to control your blood pressure by making healthy ... your health care team so you can take steps to control your blood pressure before and during ...

  16. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... normal for babies, while older teens have numbers similar to adults. Abnormal Blood Pressure Abnormal increases in ... Salt A low-sodium diet can help you manage your blood pressure. You should try to limit ...

  17. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... short-term serious illnesses. People with diabetes or chronic kidney disease should keep their blood pressure below ... blood pressure include other medical conditions such as chronic kidney disease , sleep apnea , thyroid problems, or certain ...

  18. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... bring your log of blood pressure readings. Every time you visit the health care provider, he or she should tell you what your blood pressure numbers are; if he or she does not, you should ...

  19. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... blood pressure. Angiotensin-Converting Enzyme (ACE) Inhibitors : Angiotensin-II is a hormone that narrows blood vessels, increasing blood pressure. ACE converts Angiotensin I to Angiotensin II. ACE inhibitors block this process, which stops the ...

  20. Mercury-free electrodeless discharge lamp: effect of xenon pressure and plasma parameters on luminance

    Science.gov (United States)

    Ahmad, Nazri Dagang; Kondo, Akira; Motomura, Hideki; Jinno, Masafumi

    2009-05-01

    Since there is much concern about environmental preservation, the authors have paid attention to the uses of mercury in lighting application. They have focused on the application of the xenon low-pressure inductively coupled plasma (ICP) discharge in developing cylindrical type mercury-free light sources. ICP can be operated at low filling gas pressures and demonstrates significant potential in producing high density plasma. Xenon pressure was varied from 0.1 to 100 Torr and the lamp luminance was measured. The gas pressure dependence shows an increase in luminance at pressures below 1 Torr. In order to clarify this behaviour, measurement of plasma parameters was carried out using the double probe method and its relation to lamp luminance is discussed. As the gas pressure is decreased (from 1 to 0.01 Torr), the electron temperature increases while the electron density decreases while at the same time the lamp luminance increases. There are several factors that are believed to contribute to the increase in luminance in the very low pressure region. Increases in luminance are considered to be due to the electron-ion recombination process which brings a strong recombination radiation in continuum in the visible region and also due to the effect of stochastic heating.

  1. Mercury-free electrodeless discharge lamp: effect of xenon pressure and plasma parameters on luminance

    Energy Technology Data Exchange (ETDEWEB)

    Nazri Dagang Ahmad; Kondo, Akira; Motomura, Hideki; Jinno, Masafumi, E-mail: nazri@mayu.ee.ehime-u.ac.j [Department of Electrical and Electronic Engineering, 3 Bunkyo-cho, Matsuyama, Ehime 790-8577 (Japan)

    2009-05-07

    Since there is much concern about environmental preservation, the authors have paid attention to the uses of mercury in lighting application. They have focused on the application of the xenon low-pressure inductively coupled plasma (ICP) discharge in developing cylindrical type mercury-free light sources. ICP can be operated at low filling gas pressures and demonstrates significant potential in producing high density plasma. Xenon pressure was varied from 0.1 to 100 Torr and the lamp luminance was measured. The gas pressure dependence shows an increase in luminance at pressures below 1 Torr. In order to clarify this behaviour, measurement of plasma parameters was carried out using the double probe method and its relation to lamp luminance is discussed. As the gas pressure is decreased (from 1 to 0.01 Torr), the electron temperature increases while the electron density decreases while at the same time the lamp luminance increases. There are several factors that are believed to contribute to the increase in luminance in the very low pressure region. Increases in luminance are considered to be due to the electron-ion recombination process which brings a strong recombination radiation in continuum in the visible region and also due to the effect of stochastic heating.

  2. Atmospheric pressure plasma accelerates tail regeneration in tadpoles Xenopus laevis

    Science.gov (United States)

    Rivie, A.; Martus, K.; Menon, J.

    2017-08-01

    Atmospheric pressure plasma is a partially ionized gas composed of neutral and charged particles, including electrons and ions, as well as reactive oxygen species (ROS). Recently, it is utilized as possible therapy in oncology, sterilization, skin diseases, wound healing and tissue regeneration. In this study we focused on effect of plasma exposure on tail regeneration of tadpoles, Xenopus leavis with special emphasis on role of ROS, antioxidant defenses and morphological features of the regenerate. When amputated region of the tail was exposed to the helium plasma it resulted in a faster rate of growth, elevated ROS and increase in antioxidant enzymes in the regenerate compared to that of untreated control. An increase in nitric oxide (free radical) as well as activity of nitric oxide synthase(s) were observed once the cells of the regeneration blastema - a mass of proliferating cells are ready for differentiation. Microscopically the cells of the regenerate of plasma treated tadpoles show altered morphology and characteristics of cellular hypoxia and oxidative stress. We summarize that plasma exposure accelerates the dynamics of wound healing and tail regeneration through its effects on cell proliferation and differentiation as well as angiogenesis mediated through ROS signaling.

  3. High Pressure Microwave Powered UV Light Sources

    Science.gov (United States)

    Cekic, M.; Frank, J. D.; Popovic, S.; Wood, C. H.

    1997-10-01

    Industrial microwave powered (*electrodeless*) light sources have been limited to quiescent pressures of 300 Torr of buffer gas and metal- halide fills. Recently developed multi-atmospheric electronegative bu lb fills (noble gas-halide excimers, metal halide) require electric field s for ionization that are often large multiples of the breakdown voltage for air. For these fills an auxiliary ignition system is necessary. The most successful scheme utilizes a high voltage pulse power supply and a novel field emission source. Acting together they create localized condition of pressure reduction and high free electron density. This allows the normal microwave fields to drive this small region into avalanche, ignite the bulb, and heat the plasma to it's operating poin t Standard diagnostic techniques of high density discharges are inapplicable to the excimer bulbs, because of the ionic molecular exci ted state structure and absence of self-absorption. The method for temperature determination is based on the equilibrium population of certain vibrational levels of excimer ionic excited states. Electron d ensity was determined from the measurements of Stark profiles of H_β radiation from a small amount of hydrogen mixed with noble gas and halogens. At the present time, high pressure (Te 0.5eV, ne 3 x 10^17 cm-3) production bulbs produce over 900W of radiation in a 30nm band, centered at 30nm. Similarly, these prototypes when loaded with metal-halide bulb fills produce 1 kW of radiation in 30nm wide bands, centered about the wavelength of interest.

  4. Atmospheric pressure plasma polymerization of 1,3-butadiene for hydrophobic finishing of textile substrates

    Energy Technology Data Exchange (ETDEWEB)

    Samanta, Kartick K; Jassal, Manjeet; Agrawal, Ashwini K, E-mail: ashwini@smita-iitd.co, E-mail: manjeet.jassal@smita-iitd.co [Smart and Innovative Textile Materials Group (SMITA), Department of Textile Technology, Indian Institute of Technology, Hauz Khas, New Delhi-110016 (India)

    2010-02-01

    Atmospheric pressure plasma processing of textile has both ecological and economical advantages over the wet-chemical processing. However, reaction in atmospheric pressure plasma has important challenges to be overcome before it can be successfully used for finishing applications in textile. These challenges are (i) generating stable glow plasma in presence liquid/gaseous monomer, and (ii) keeping the generated radicals active in the presence of contaminants such as oxygen and air. In this study, a stable glow plasma was generated at atmospheric pressure in the mixture of gaseous reactive monomer-1,3-butadiene and He and was made to react with cellulosic textile substrate. After 12 min of plasma treatment, the hydrophilic surface of the cellulosic substrate turned into highly hydrophobic surface. The hydrophobic finish was found to be durable to soap washing. After soap washing, a water drop of 37 {mu}l took around 250 s to get absorbed in the treated sample compared to < 1 s in the untreated samples. The plasma modified samples showed water contact angle of around 134{sup 0}. Both top and bottom sides of the fabric showed similar hydrophobic results in terms of water absorbency and contact angle. The results may be attributed to chemical reaction of butadiene with the cellulosic textile substrate. The surface characterization of the plasma modified samples under SEM and AFM revealed modification of the surface under <100 nm. The results showed that atmospheric pressure plasma can be successfully used for carrying out reaction of 1,3-butadiene with cellulosic textile substrates for producing hydrophobic surface finish.

  5. High blood pressure and eye disease

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000999.htm High blood pressure and eye disease To use the sharing features on this page, please enable JavaScript. High blood pressure can damage blood vessels in the retina . The ...

  6. Re-appraisal and extension of the Gratton-Vargas two-dimensional analytical snowplow model of plasma focus - III: Scaling theory for high pressure operation and its implications

    CERN Document Server

    Auluck, S K H

    2016-01-01

    Recent work on the revised Gratton-Vargas model has demonstrated that there are some aspects of Dense Plasma Focus (DPF) which are not sensitive to details of plasma dynamics and are well captured in an oversimplified model assumption which contains very little plasma physics. A hyperbolic conservation law formulation of DPF physics reveals the existence of a velocity threshold related to specific energy of dissociation and ionization, above which, the work done during shock propagation is adequate to ensure dissociation and ionization of the gas being ingested. These developments are utilized to formulate an algorithmic definition of DPF optimization that is valid in a wide range of applications, not limited to neutron emission. A universal scaling theory of DPF design optimization is proposed and illustrated for designing devices working at one or two orders higher pressure of deuterium than the current practice of designs optimized at pressures less than 10 mbar of deuterium. These examples show that the u...

  7. Nanoparticle formation in a low pressure argon/aniline RF plasma

    Science.gov (United States)

    Pattyn, C.; Kovacevic, E.; Hussain, S.; Dias, A.; Lecas, T.; Berndt, J.

    2018-01-01

    The formation of nanoparticles in low temperature plasmas is of high importance for different fields: from astrophysics to microelectronics. The plasma based synthesis of nanoparticles is a complex multi-scale process that involves a great variety of different species and comprises timescales ranging from milliseconds to several minutes. This contribution focuses on the synthesis of nanoparticles in a low temperature, low pressure capacitively coupled plasma containing mixtures of argon and aniline. Aniline is commonly used for the production of polyaniline, a material that belongs to the family of conductive polymers, which has attracted increasing interest in the last few years due to the large number of potential applications. The nanoparticles which are formed in the plasma volume and levitate there due to the collection of negative charges are investigated in this contribution by means of in-situ FTIR spectroscopy. In addition, the plasma is analyzed by means of plasma (ion) mass spectroscopy. The experiments reveal the possibility to synthesize nanoparticles both in continuous wave and in pulsed discharges. The formation of particles in the plasma volume can be suppressed by pulsing the plasma in a specific frequency range. The in-situ FTIR analysis also reveals the influence of the argon plasma on the characteristics of the nanoparticles.

  8. Sterilization of Surfaces with a Handheld Atmospheric Pressure Plasma

    Science.gov (United States)

    Hicks, Robert; Habib, Sara; Chan, Wai; Gonzalez, Eleazar; Tijerina, A.; Sloan, Mark

    2009-10-01

    Low temperature, atmospheric pressure plasmas have shown great promise for decontaminating the surfaces of materials and equipment. In this study, an atmospheric pressure, oxygen and argon plasma was investigated for the destruction of viruses, bacteria, and spores. The plasma was operated at an argon flow rate of 30 L/min, an oxygen flow rate of 20 mL/min, a power density of 101.0 W/cm^3 (beam area = 5.1 cm^2), and at a distance from the surface of 7.1 mm. An average 6log10 reduction of viable spores was obtained after only 45 seconds of exposure to the reactive gas. By contrast, it takes more than 35 minutes at 121^oC to sterilize anthrax in an autoclave. The plasma properties were investigated by numerical modeling and chemical titration with nitric oxide. The numerical model included a detailed reaction mechanism for the discharge as well as for the afterglow. It was predicted that at a delivered power density of 29.3 W/cm^3, 30 L/min argon, and 0.01 volume% O2, the plasma generated 1.9 x 10^14 cm-3 O atoms, 1.6 x 10^12 cm-3 ozone, 9.3 x 10^13 cm-3 O2(^1δg), and 2.9 x 10^12 cm-3 O2(^1σ^+g) at 1 cm downstream of the source. The O atom density measured by chemical titration with NO was 6.0 x 10^14 cm-3 at the same conditions. It is believe that the oxygen atoms and the O2(^1δg) metastables were responsible for killing the anthrax and other microorganisms.

  9. High pressure metrology for industrial applications

    Science.gov (United States)

    Sabuga, Wladimir; Rabault, Thierry; Wüthrich, Christian; Pražák, Dominik; Chytil, Miroslav; Brouwer, Ludwig; Ahmed, Ahmed D. S.

    2017-12-01

    To meet the needs of industries using high pressure technologies, in traceable, reliable and accurate pressure measurements, a joint research project of the five national metrology institutes and the university was carried out within the European Metrology Research Programme. In particular, finite element methods were established for stress–strain analysis of elastic and nonlinear elastic–plastic deformation, as well as of contact processes in pressure-measuring piston-cylinder assemblies, and high-pressure components at pressures above 1 GPa. New pressure measuring multipliers were developed and characterised, which allow realisation of the pressure scale up to 1.6 GPa. This characterisation is based on research including measurements of material elastic constants by the resonant ultrasound spectroscopy, hardness of materials of high pressure components, density and viscosity of pressure transmitting liquids at pressures up to 1.4 GPa and dimensional measurements on piston-cylinders. A 1.6 GPa pressure system was created for operation of the 1.6 GPa multipliers and calibration of high pressure transducers. A transfer standard for 1.5 GPa pressure range, based on pressure transducers, was built and tested. Herewith, the project developed the capability of measuring pressures up to 1.6 GPa, from which industrial users can calibrate their pressure measurement devices for accurate measurements up to 1.5 GPa.

  10. Depth Gauge for Liquids Under High Pressure

    Science.gov (United States)

    Zuckerwar, A. J.; Mazel, D. S.

    1987-01-01

    Piezoelectric element mounted in hole drilled in high-pressure plug. Transducer used to measure depth of liquid when pressure in vessel high. New configuration transmits ultrasonic vibration directly into liquid, enhancing signal strength, accuracy, and range, yet piezoelectric element protected from high-pressure liquid.

  11. Computational Simulation of High Energy Density Plasmas

    Science.gov (United States)

    2009-10-30

    the imploding liner. The PFS depends on a lithium barrier foil slowing the advance of deuterium up the coaxial gun to the corner. There the plasma ...the coaxial gun section, and Figure 4 shows the physical state of the plasma just prior to pinch. Figure 5 shows neutron yield reaching 1014 in this...details the channel geometry between the center cylinder and coaxial gas gun . The deuterium injection starts when the pressure of the deuterium gas in

  12. Plasma high-order-harmonic generation from ultraintense laser pulses

    Science.gov (United States)

    Tang, Suo; Kumar, Naveen; Keitel, Christoph H.

    2017-05-01

    Plasma high-order-harmonic generation from an extremely intense short-pulse laser is explored by including the effects of ion motion, electron-ion collisions, and radiation reaction force in the plasma dynamics. The laser radiation pressure induces plasma ion motion through the hole-boring effect, resulting in frequency shifting and widening of the harmonic spectra. The classical radiation reaction force slightly mitigates the frequency broadening caused by the ion motion. Based on the results and physical considerations, parameter maps highlighting the optimum regions for generating a single intense attosecond pulse and coherent XUV radiation are presented.

  13. Atmospheric-pressure plasma decontamination/sterilization chamber

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, Hans W. (Los Alamos, NM); Selwyn, Gary S. (Los Alamos, NM)

    2001-01-01

    An atmospheric-pressure plasma decontamination/sterilization chamber is described. The apparatus is useful for decontaminating sensitive equipment and materials, such as electronics, optics and national treasures, which have been contaminated with chemical and/or biological warfare agents, such as anthrax, mustard blistering agent, VX nerve gas, and the like. There is currently no acceptable procedure for decontaminating such equipment. The apparatus may also be used for sterilization in the medical and food industries. Items to be decontaminated or sterilized are supported inside the chamber. Reactive gases containing atomic and metastable oxygen species are generated by an atmospheric-pressure plasma discharge in a He/O.sub.2 mixture and directed into the region of these items resulting in chemical reaction between the reactive species and organic substances. This reaction typically kills and/or neutralizes the contamination without damaging most equipment and materials. The plasma gases are recirculated through a closed-loop system to minimize the loss of helium and the possibility of escape of aerosolized harmful substances.

  14. Atmospheric-Pressure Plasma Cleaning of Contaminated Surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Robert F. Hicks; Hans W. Herrmann

    2003-12-15

    The purpose of this project was to demonstrate a practical, environmentally benigh technology for the surface decontamination and decommissioning of radioactive waste. A low temperature, atmospheric pressure plasma has been developed with initial support from the DOE, Environmental Management Sciences Program. This devise selectively etches radioactive metals from surfaces, rendering objects radiation free and suitable for decommissioning. The volatile reaction products are captured on filters, which yields a tremendous reduction in the volume of the waste. The technology shows a great potential for accelerating the clean-up effort for the equipment and structures contaminated with radioactive materials within the DOE complex. The viability of this technology has been demonstrated by selectively and rapidly stripping uranium from stainless steel surfaces at low temperature. Studies on uranium oxide have shown that etch rates of 4.0 microns per minute can be achieved at temperature below 473 K. Over the past three years, we have made numerous improvements in the design of the atmospheric pressure plasma source. We are now able to scale up the plasma source to treat large surface areas.

  15. World of high pressure. Koatsuryoku no sekai

    Energy Technology Data Exchange (ETDEWEB)

    Moritoki, M.; Kanda, T. (Kobe Steel, Ltd., Kobe (Japan))

    1993-05-01

    The present article describes development and current status of high pressure technology. It introduces applications of high pressure technology to chemical reactions and processings, utilizations of phase changes and supercritical fluids, and applications of high pressure to food processings. Contributions of high pressure technology to synthetic chemistry are mentioned as for industrialization of syntheses of ammonia, urea and methanol, and invention of synthesis of polyethylene. Processing technologies utilizing high pressure are also mentioned as for cold isostatic pressing, hot isostatic pressing, hydrostatic extrusion technique, water jet working technique, and explosive forming technique. Introduced are application of phase changes under high pressure, such as high pressure synthesis of diamond and pressurized crystallization technology, and supercritical extraction technology using water and carbon dioxide. Pressurized food processings of mandarin orange, jam, and grapefruit are described. Furthermore, current status of fundamental technologies of high pressure installations is provided as for pressure vessel technology, pressure generation and control technology, and pressure sealing technology. 12 refs., 15 figs., 1 tab.

  16. Searching for order in atmospheric pressure plasma jets

    Science.gov (United States)

    Schäfer, Jan; Sigeneger, Florian; Šperka, Jiří; Rodenburg, Cornelia; Foest, Rüdiger

    2018-01-01

    The self-organized discharge behaviour occurring in a non-thermal radio-frequency plasma jet in rare gases at atmospheric pressure was investigated. The frequency of the azimuthal rotation of filaments in the active plasma volume and their inclination were measured along with the gas temperature under varying discharge conditions. The gas flow and heating were described theoretically by a three-dimensional hydrodynamic model. The rotation frequencies obtained by both methods qualitatively agree. The results demonstrate that the plasma filaments forming an inclination angle α with the axial gas velocity u z are forced to a transversal movement with the velocity {u}φ =\\tan (α )\\cdot {u}z, which is oriented in the inclination direction. Variations of {u}φ in the model reveal that the observed dynamics minimizes the energy loss due to convective heat transfer by the gas flow. The control of the self-organization regime motivates the application of the plasma jet for precise and reproducible material processing.

  17. High-Pressure Lightweight Thrusters

    Science.gov (United States)

    Holmes, Richard; McKechnie, Timothy; Shchetkovskiy, Anatoliy; Smirnov, Alexander

    2013-01-01

    Returning samples of Martian soil and rock to Earth is of great interest to scientists. There were numerous studies to evaluate Mars Sample Return (MSR) mission architectures, technology needs, development plans, and requirements. The largest propulsion risk element of the MSR mission is the Mars Ascent Vehicle (MAV). Along with the baseline solid-propellant vehicle, liquid propellants have been considered. Similar requirements apply to other lander ascent engines and reaction control systems. The performance of current state-ofthe- art liquid propellant engines can be significantly improved by increasing both combustion temperature and pressure. Pump-fed propulsion is suggested for a single-stage bipropellant MAV. Achieving a 90-percent stage propellant fraction is thought to be possible on a 100-kg scale, including sufficient thrust for lifting off Mars. To increase the performance of storable bipropellant rocket engines, a high-pressure, lightweight combustion chamber was designed. Iridium liner electrodeposition was investigated on complex-shaped thrust chamber mandrels. Dense, uniform iridium liners were produced on chamber and cylindrical mandrels. Carbon/carbon composite (C/C) structures were braided over iridium-lined mandrels and densified by chemical vapor infiltration. Niobium deposition was evaluated for forming a metallic attachment flange on the carbon/ carbon structure. The new thrust chamber was designed to exceed state-of-the-art performance, and was manufactured with an 83-percent weight savings. High-performance C/Cs possess a unique set of properties that make them desirable materials for high-temperature structures used in rocket propulsion components, hypersonic vehicles, and aircraft brakes. In particular, more attention is focused on 3D braided C/Cs due to their mesh-work structure. Research on the properties of C/Cs has shown that the strength of composites is strongly affected by the fiber-matrix interfacial bonding, and that weakening

  18. Re-appraisal and extension of the Gratton-Vargas two-dimensional analytical snowplow model of plasma focus. III. Scaling theory for high pressure operation and its implications

    Science.gov (United States)

    Auluck, S. K. H.

    2016-12-01

    Recent work on the revised Gratton-Vargas model (Auluck, Phys. Plasmas 20, 112501 (2013); 22, 112509 (2015) and references therein) has demonstrated that there are some aspects of Dense Plasma Focus (DPF), which are not sensitive to details of plasma dynamics and are well captured in an oversimplified model assumption, which contains very little plasma physics. A hyperbolic conservation law formulation of DPF physics reveals the existence of a velocity threshold related to specific energy of dissociation and ionization, above which, the work done during shock propagation is adequate to ensure dissociation and ionization of the gas being ingested. These developments are utilized to formulate an algorithmic definition of DPF optimization that is valid in a wide range of applications, not limited to neutron emission. This involves determination of a set of DPF parameters, without performing iterative model calculations, that lead to transfer of all the energy from the capacitor bank to the plasma at the time of current derivative singularity and conversion of a preset fraction of this energy into magnetic energy, while ensuring that electromagnetic work done during propagation of the plasma remains adequate for dissociation and ionization of neutral gas being ingested. Such a universal optimization criterion is expected to facilitate progress in new areas of DPF research that include production of short lived radioisotopes of possible use in medical diagnostics, generation of fusion energy from aneutronic fuels, and applications in nanotechnology, radiation biology, and materials science. These phenomena are expected to be optimized for fill gases of different kinds and in different ranges of mass density compared to the devices constructed for neutron production using empirical thumb rules. A universal scaling theory of DPF design optimization is proposed and illustrated for designing devices working at one or two orders higher pressure of deuterium than the current

  19. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... your risk for health problems. Greater amounts of weight loss can improve blood pressure readings, lower LDL cholesterol , ... blood pressure and triglyceride levels, a type of fat found in the blood. Alcohol also adds extra calories, which may cause weight gain. Men should have no more than two ...

  20. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... short-term serious illnesses. People with diabetes or chronic kidney disease should keep their blood pressure below 130/80 ... blood pressure include other medical conditions such as chronic kidney disease , sleep apnea , thyroid problems, or certain tumors. This ...

  1. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... provider may ask you to come into the office on different days and at different times to take your blood pressure. The health care provider also may ask you to check readings at home or at other locations that have blood pressure ...

  2. Simulation of propagation of the HPM in the low-pressure argon plasma

    Science.gov (United States)

    Zhigang, LI; Zhongcai, YUAN; Jiachun, WANG; Jiaming, SHI

    2018-02-01

    The propagation of the high-power microwave (HPM) with a frequency of 6 GHz in the low-pressure argon plasma was studied by the method of fluid approximation. The two-dimensional transmission model was built based on the wave equation, the electron drift-diffusion equations and the heavy species transport equations, which were solved by means of COMSOL Multiphysics software. The simulation results showed that the propagation characteristic of the HPM was closely related to the average electron density of the plasma. The attenuation of the transmitted wave increased nonlinearly with the electron density. Specifically, the growth of the attenuation slowed down as the electron density increased uniformly. In addition, the concrete transmission process of the HPM wave in the low-pressure argon plasma was given.

  3. Effects of imipramine of the orthostatic changes in blood pressure, heart rate and plasma catecholamines

    DEFF Research Database (Denmark)

    Nielsen, J R; Johansen, Torben; Arentoft, A

    1983-01-01

    The effect of imipramine on the orthostatic changes in heart rate, blood pressure and plasma catecholamines were examined in six healthy male subjects on two occasions on high sodium balance (Na+ excretion greater than 120 mmol per day) and on low sodium balance (Na+ excretion less than 110 mmol...... ingestion on a high sodium balance. The plasma catecholamine levels in supine and standing position were not influenced by imipramine or by the changes in sodium balance. The data may suggest that inhibition of presynaptic reuptake of noradrenaline and/or alpha 2-adrenoceptor blockade causes the moderate...

  4. On density and pressure variations in the solar wind plasma

    OpenAIRE

    Jonson, Martin

    2007-01-01

    A study of ACE solar wind data at lAU, for the period from 1998 to early 2005, was conducted. This was done in order to find sudden solar wind pressure enhancements accounting for plasma transfer through the magnetopause. In order to get information about the extent and orientation of the structures found, a correlation of found events to data from the Wind satellite was done. The enhancements considered are those with a relative increase exceeding unity. These are found by applying a 1-hour ...

  5. Atmospheric pressure plasma treatment of glassy carbon for adhesion improvement

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Mortensen, Henrik Junge; Stenum, Bjarne

    2007-01-01

    density increased with the plasma treatments. Adhesion test of the treated glassy carbon covered with cured epoxy showed cohesive failure, indicating strong bonding after the treatments. This is in contrast to the adhesion tests of untreated samples where the epoxy readily peeled off the glassy carbon.......Glassy carbon plates were treated with an atmospheric pressure dielectric barrier discharge (DBD). He gas, gas mixtures of He and reactive gases such as O2, CO2 and NH3, Ar gas and Ar/NH3 gas mixture were used as treatment gases. The oxygen and nitrogen contents on the surface as well as defect...

  6. HIGH BLOOD PRESSURE: DOES THIS CONCERN ME?

    CERN Document Server

    2007-01-01

    To find out, the Medical Service's nurses are organising A HIGH BLOOD PRESSURE SCREENING AND PREVENTION CAMPAIGN from Monday, 26th to Thursday, 29th March 2007 at the Infirmary - Building 57 - ground floor A blood pressure test, advice, information and, if necessary, referral for specialist medical treatment will be offered to any person working on the CERN site. High blood pressure is a stealth threat to health. So come and get your blood pressure checked.

  7. HIGH BLOOD PRESSURE: DOES THIS CONCERN ME?

    CERN Multimedia

    2007-01-01

    To find out, the Medical Service's nurses are organising A HIGH BLOOD PRESSURE SCREENING AND PREVENTION CAMPAIGN from Monday, 26th to Thursday, 29th March 2007 at the Infirmary - Building 57 - ground floor A blood pressure test, advice, information and, if necessary, referral for specialist medical treatment will be offered to any person working on the CERN site. High blood pressure is a silent threat to health. So come and get your blood pressure checked.

  8. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... 5 percent can lower your risk for health problems. Greater amounts of weight loss can improve blood pressure readings, lower LDL cholesterol , and increase HDL cholesterol . However, research shows that no matter your weight, it is ...

  9. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... heart healthy. Limiting Sodium and Salt A low-sodium diet can help you manage your blood pressure. You should try to limit the amount of sodium that you eat. This means choosing and preparing ...

  10. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Search Form Search the NHLBI, use the drop down list to select: the entire site, the Health ... flow more freely, causing blood pressure to go down. Alpha-Beta Blockers: Reduce nerve impulses the same ...

  11. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Organization NHLBI Director Budget, Planning, & Legislative Advisory Committees Jobs Contact Us FAQs Home » Health Information for the ... track blood pressure readings over a period of time, the health care provider may ask you to ...

  12. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... health problems. Greater amounts of weight loss can improve blood pressure readings, lower LDL cholesterol , and increase ... manage stress, relax, and cope with problems can improve your emotional and physical health and can lower ...

  13. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... a result, blood pressure goes down. Central Acting Agents: Act in the brain to decrease nerve signals ... healthy future, follow your treatment plan closely and work with your health care team. Healthy Lifestyle Changes ...

  14. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... renin-angiotensin-aldosterone system makes angiotensin and aldosterone hormones . Angiotensin narrows or constricts blood vessels, which can ... pressure. Medicines Prescription medicines such as asthma or hormone therapies, including birth control pills and estrogen, and ...

  15. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... SPRINT trial played a key role in the evolution of the new blood pressure guidelines Health experts ... National Institute of Health Department of Health and Human Services OIG USA.gov

  16. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... face, arms, or legs; trouble speaking or understanding speech; and trouble seeing. Diagnosis For most patients, health ... result, blood pressure goes down. Central Acting Agents: Act in the brain to decrease nerve signals that ...

  17. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... help to lower your blood pressure. Angiotensin-Converting Enzyme (ACE) Inhibitors : Angiotensin-II is a hormone that ... and Kidney Disease (National Institute of Diabetes and Digestive and Kidney Diseases) RELATED NEWS December 13, 2017 | ...

  18. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... help to lower your blood pressure. Angiotensin-Converting Enzyme (ACE) Inhibitors : Angiotensin-II is a hormone that ... National Institute of Health Department of Health and Human Services OIG USA.gov

  19. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... such as chronic kidney disease , sleep apnea , thyroid problems, or certain tumors. This happens because these other ... blood pressure or prevent complications and long-term problems associated with this condition, such as coronary heart ...

  20. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Science Science Home Blood Disorders and Blood Safety Sleep Science and Sleep Disorders Lung Diseases Heart and Vascular Diseases Precision ... normal for blood pressures to change when you sleep, wake up, or are excited or nervous. When ...

  1. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... and adults. They use a gauge, stethoscope or electronic sensor, and a blood pressure cuff. With this ... the American College of Cardiology (ACC), the guidelines now define hypertension as a systolic blood... View all ...

  2. Controlling your high blood pressure

    Science.gov (United States)

    ... medicine or your blood pressure Alternative Names Controlling hypertension ... Diabetes Association. Standards of Medical Care in Diabetes-2016 Abridged for Primary Care Providers. Clin Diabetes . 2016;34(1):3- ...

  3. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Are less likely to achieve target blood pressure goals with treatment. Overweight You are more likely to ... 30 or more is considered obese. A general goal to aim for is a BMI below 25. ...

  4. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... of alcohol Lack of physical activity Overweight and Obesity Research studies show that being overweight or obese ... EVENT The Role of Microbiota in Blood Pressure Regulation Executive Summary June 10, 2016 Bethesda, MD The ...

  5. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... to the bathroom before the test. Sit for 5 minutes before the test. To track blood pressure ... and Type Your health care provider usually takes 2–3 readings at several medical appointments to diagnose ...

  6. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... to Aim for a Healthy Weight . Limiting Alcohol Intake Limit alcohol intake. Too much alcohol will raise your blood pressure ... physically active. Maintain a healthy weight. Limit alcohol intake. Other lifestyle changes can improve your overall health, ...

  7. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... that are heart healthy and low in fat, cholesterol, and salt. The DASH eating plan is a ... loss can improve blood pressure readings, lower LDL cholesterol , and increase HDL cholesterol . However, research shows that ...

  8. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... a period of time, the health care provider may ask you to come into the office on ... your blood pressure. The health care provider also may ask you to check readings at home or ...

  9. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Blood Pressure Building 31 31 Center Drive Bethesda, MD 20892 Learn more about getting to NIH Get ... and Funding Building 31 31 Center Drive Bethesda, MD 20892 Learn more about getting to NIH Connect ...

  10. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... include: Whole grains Fruits, such as apples, bananas, oranges, pears, and prunes Vegetables, such as broccoli, cabbage, ... a result, blood pressure goes down. Central Acting Agents: Act in the brain to decrease nerve signals ...

  11. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... ACE inhibitors block this process, which stops the production of Angiotensin II, lowering blood pressure. Angiotensin II ... The National Heart, Lung, and Blood Institute (NHLBI) leads or sponsors many studies aimed at preventing, diagnosing, ...

  12. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... a day. One drink is: 12 ounces of beer 5 ounces of wine 1½ ounces of liquor ... ACE inhibitors block this process, which stops the production of Angiotensin II, lowering blood pressure. Angiotensin II ...

  13. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Health care workers check blood pressure readings the same way for children, teens, and adults. They use ... are outside average numbers for children of the same age, gender, and height . Once your health care ...

  14. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... pressure is a common disease in which blood flows through blood vessels (arteries) at higher than normal ... press on nearby body parts, or block blood flow. The signs and symptoms that develop depend on ...

  15. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... NHLBI About NHLBI Home Mission and Strategic Vision Leadership Scientific Divisions Operations and Administration Advisory Committees Budget ... normal for babies, while older teens have numbers similar to adults. Abnormal Blood Pressure Abnormal increases in ...

  16. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... risk for health problems. Greater amounts of weight loss can improve blood pressure readings, lower ... to maintain good health. A useful measure of overweight and obesity is body mass index (BMI). BMI measures your ...

  17. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Salt A low-sodium diet can help you manage your blood pressure. You should try to limit ... Managing and Coping With Stress Learning how to manage stress, relax, and cope with problems can improve ...

  18. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... the test: Don’t drink coffee or smoke cigarettes for 30 minutes prior to the test. Go ... DASH My Blood Pressure Wallet Card Other Resources Cigarette and Tobacco Facts (National Institute on Drug Abuse) ...

  19. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... lead to cognitive changes. Signs and symptoms include memory loss, difficulty finding words, and losing focus during ... blood pressure numbers are outside average numbers for children of the same age, gender, and height . Once ...

  20. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... lead to an increase in blood pressure. Aldosterone controls how the kidneys balance fluid and salt levels. ... such as asthma or hormone therapies, including birth control pills and estrogen, and over-the-counter medicines ...

  1. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... improve your overall health, such as: If you smoke , quit. Get plenty of sleep. Drink more water. Medicines Take all blood pressure medicines that your health care provider prescribes. Know the names and doses of ...

  2. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Heart and Vascular Diseases Precision Medicine Activities Obesity, Nutrition, and Physical Activity Population and Epidemiology Studies Women’s ... healthy. Limiting Sodium and Salt A low-sodium diet can help you manage your blood pressure. You ...

  3. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... care providers prescribe children and teens medicines at special doses that are safe and effective in children. ... different set of blood pressure medications or other special treatments. To achieve the best control of your ...

  4. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... pressure. The DASH eating plan focuses on fruits, vegetables, whole grains, and other foods that are heart ... such as apples, bananas, oranges, pears, and prunes Vegetables, such as broccoli, cabbage, and carrots Legumes, such ...

  5. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... narrow in the kidneys, possibly causing kidney failure. Cognitive Changes: Research shows that over time, higher blood pressure numbers can lead to cognitive changes. Signs and symptoms include memory loss, difficulty ...

  6. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... healthy. Limiting Sodium and Salt A low-sodium diet can help you manage your blood pressure. You ... twice a week When following a heart-healthy diet, you should avoid eating: A lot of red ...

  7. Prevention of High Blood Pressure

    Science.gov (United States)

    ... include: Whole grains Fruits, such as apples, bananas, oranges, pears, and prunes Vegetables, such as broccoli, cabbage, ... ACE inhibitors block this process, which stops the production of Angiotensin II, lowering blood pressure. Angiotensin II ...

  8. What Causes High Blood Pressure?

    Science.gov (United States)

    ... include: Whole grains Fruits, such as apples, bananas, oranges, pears, and prunes Vegetables, such as broccoli, cabbage, ... ACE inhibitors block this process, which stops the production of Angiotensin II, lowering blood pressure. Angiotensin II ...

  9. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... include: Whole grains Fruits, such as apples, bananas, oranges, pears, and prunes Vegetables, such as broccoli, cabbage, ... ACE inhibitors block this process, which stops the production of Angiotensin II, lowering blood pressure. Angiotensin II ...

  10. Living with High Blood Pressure

    Science.gov (United States)

    ... include: Whole grains Fruits, such as apples, bananas, oranges, pears, and prunes Vegetables, such as broccoli, cabbage, ... ACE inhibitors block this process, which stops the production of Angiotensin II, lowering blood pressure. Angiotensin II ...

  11. Diagnosis of High Blood Pressure

    Science.gov (United States)

    ... include: Whole grains Fruits, such as apples, bananas, oranges, pears, and prunes Vegetables, such as broccoli, cabbage, ... ACE inhibitors block this process, which stops the production of Angiotensin II, lowering blood pressure. Angiotensin II ...

  12. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... A lot of red meat Palm and coconut oils Sugary foods and beverages In the National Heart, ... work with your health care team. Healthy Lifestyle Changes You can help control your blood pressure by ...

  13. Effects of atmospheric pressure plasma jet with floating electrode on murine melanoma and fibroblast cells

    Science.gov (United States)

    Xu, G.; Liu, J.; Yao, C.; Chen, S.; Lin, F.; Li, P.; Shi, X.; Zhang, Guan-Jun

    2017-08-01

    Atmospheric pressure cold plasma jets have been recently shown as a highly promising tool in certain cancer therapies. In this paper, an atmospheric pressure plasma jet (APPJ) with a one inner floating and two outer electrode configuration using helium gas for medical applications is developed. Subjected to a range of applied voltages with a frequency of 19.8 kHz at a fixed rate of gas flow (i.e., 3 l/min), electrical and optical characteristics of the APPJ are investigated. Compared with the device only with two outer electrodes, higher discharge current, longer jet, and more active species in the plasma plume at the same applied voltage together with the lower gas breakdown voltage can be achieved through embedding a floating inner electrode. Employing the APPJ with a floating electrode, the effects of identical plasma treatment time durations on murine melanoma cancer and normal fibroblast cells cultured in vitro are evaluated. The results of cell viability, cell apoptosis, and DNA damage detection show that the plasma can inactivate melanoma cells in a time-dependent manner from 10 s to 60 s compared with the control group (p melanoma cells at the same treatment time. The different basal reactive oxygen species level and antioxidant superoxide dismutase level of two kinds of cells may account for their different responses towards the identical plasma exposure.

  14. Cavity-enhanced absorption spectroscopy to characterize atmospheric pressure plasma jets

    Science.gov (United States)

    van Helden, Jean-Pierre; Nave, Andy; Reuter, Stephan; Roepcke, Juergen; Gianella, Michele; Ritchie, Grant

    2016-09-01

    Non-equilibrium atmospheric pressure plasma jets gain more and more interest as their technological applications increase in diverse fields such as material processing and plasma medicine. Hence, it is essential to diagnose the fluxes of the species generated by these plasma sources to identify relevant fundamental processes and to improve process efficiency. Especially for a comprehensive understanding of the kinetics of the transient species involved, high precision measurements of reactive molecular precursors, free radicals and to identify of any short lived species are of crucial importance. However, the detection of transient species in these type of plasmas poses a challenge for diagnostic techniques as the plasmas typically have small dimensions and high density gradients in space and time. We have overcome these limitations by using cavity-enhanced absorption spectroscopy (CEAS). In this contribution, the latest results concerning the detection of transient species in two types of plasma jets employing CEAS in the near- and mid-infrared spectral range will be presented. We will show that with these methods spatially resolved investigations of concentrations in the mm sized effluent of the plasma jet can be achieved.

  15. High-pressure study on some superconductors

    CERN Document Server

    Li, K Q; Yao, Y S; Che, G C; Zhao, Z X

    2002-01-01

    High-pressure study has played an important role in the investigation of conventional superconductors. Since the discovery of cuprate superconductors, high-pressure study has become even more important, especially as regards high-pressure synthesis and the effect of pressure. In this report, the new materials Ca-doped Pr-123, (Fe, Cu)-1212, and MgB sub 2 - a very new and interesting system synthesized under high pressure with good quality - will be discussed. Chemical inner pressure has been thought to explain the high T sub c of Ca-doped Pr-123. As another possibility, the replacement of the physical pressure effect by a chemical effect will be discussed.

  16. A Coupled Plasma-Sheath Model for High Density Sources

    Science.gov (United States)

    Bose, Deepak; Govindan, T. R.; Meyyappan, M.

    2000-01-01

    High density, low pressure plasmas are used for etching and deposition in microelectronics fabrication processes. The process characteristics are strongly determined by the ion energy distribution (IED) and the ion flux arriving at the substrate that are responsible for desorption of etch products and neutral dissociation at the surface. The ion flux and energy are determined by a self- consistent modeling of the bulk plasma, where the ions and the neutral radicals are produced, and the sheath, where the ions are accelerated. Due to their widely different time scales, it is a formidable task to self-consistently resolve non-collisional sheath in a high density bulk plasma model. In this work, we first describe a coupled plasma-sheath model that attempts to resolve the non-collisional sheath in a reactor scale model. Second, we propose a semianalytical radio frequency (RF) sheath model to improve ion dynamics.

  17. Evaluation of Low-Pressure Cold Plasma for Disinfection of ISS Grown Produce and Metal Instruments

    Science.gov (United States)

    Hummerick, Mary E.; Hintze, Paul E.; Maloney, Philip R.; Spencer, Lashelle E.; Coutts, Janelle L.; Franco, Carolina

    2016-01-01

    Low pressure cold plasma, using breathing air as the plasma gas, has been shown to be effective at precision cleaning aerospace hardware at Kennedy Space Center.Both atmospheric and low pressure plasmas are relatively new technologies being investigated for disinfecting agricultural commodities and medical instruments.

  18. High pressure synthesis gas conversion. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    The purpose of this research project is to build and test a high pressure fermentation system for the production of ethanol from synthesis gas. The fermenters, pumps, controls, and analytical system were procured or fabricated and assembled in our laboratory. This system was then used to determine the effects of high pressure on growth and ethanol production by Clostridium ljungdahlii. The limits of cell concentration and mass transport relationships were found in CSTR and immobilized cell reactors (ICR). The minimum retention times and reactor volumes were found for ethanol production in these reactors. A maximum operating pressure of 150 psig has been shown to be possible for C. ljungdahlli with the medium of Phillips et al. This medium was developed for atmospheric pressure operation in the CSTR to yield maximum ethanol concentrations and thus is not best for operation at elevated pressures. It is recommended that a medium development study be performed for C. ljungdahlii at increased pressure. Cell concentration, gas conversion and product concentration profiles were presented for C. ljungdahlii as a function of gas flow rate, the variable which affects bacterium performance the most. This pressure was chosen as a representative pressure over the 0--150 psig operating pressure range for the bacterium. Increased pressure negatively affected ethanol productivity probably due to the fact that medium composition was designed for atmospheric pressure operation. Medium development at increased pressure is necessary for high pressure development of the system.

  19. Sterilization Efficiency of Spore forming Bacteria in Powdery Food by Atmospheric Pressure Plasmas Sterilizer

    Science.gov (United States)

    Nagata, Masayoshi; Tanaka, Masashi; Kikuchi, Yusuke

    2015-09-01

    To provide food sterilization method capable of killing highly heat resistant spore forming bacteria, we have studied effects of plasma treatment method at atmospheric pressure in order to develop a new high speed plasma sterilization apparatus with a low cost and a high efficiency. It is also difficult even for the plasma treatment to sterilize powdery food including spices such as soybean, basil and turmeric. This paper describes that an introduction of mechanical rotation of a treatment space increases the efficiency so that perfect inactivation of spore forming bacteria in these materials by a short treatment time has been demonstrated in our experiments. We also will discuss the sterilization mechanism by dielectric barrier discharge.

  20. High Precision Pressure Measurement with a Funnel

    Science.gov (United States)

    Lopez-Arias, T.; Gratton, L. M.; Oss, S.

    2008-01-01

    A simple experimental device for high precision differential pressure measurements is presented. Its working mechanism recalls that of a hydraulic press, where pressure is supplied by insufflating air under a funnel. As an application, we measure air pressure inside a soap bubble. The soap bubble is inflated and connected to a funnel which is…

  1. Synthesis and Characterization of Nanofibrous Polyaniline Thin Film Prepared by Novel Atmospheric Pressure Plasma Polymerization Technique

    Directory of Open Access Journals (Sweden)

    Choon-Sang Park

    2016-01-01

    Full Text Available This work presents a study on the preparation of plasma-polymerized aniline (pPANI nanofibers and nanoparticles by an intense plasma cloud type atmospheric pressure plasma jets (iPC-APPJ device with a single bundle of three glass tubes. The nano size polymer was obtained at a sinusoidal wave with a peak value of 8 kV and a frequency of 26 kHz under ambient air. Discharge currents, photo-sensor amplifier, and optical emission spectrometer (OES techniques were used to analyze the plasma produced from the iPC-APPJ device. Field emission scanning electron microscopy (FE-SEM, transmission electron microscopy (TEM, Fourier transform infrared spectroscopy (FT-IR, gas chromatography-mass spectrometry (GC-MS, and gel permeation chromatography (GPC techniques were used to analyze the pPANI. FE-SEM and TEM results show that pPANI has nanofibers, nanoparticles morphology, and polycrystalline characteristics. The FT-IR and GC-MS analysis show the characteristic polyaniline peaks with evidence that some quinone and benzene rings are broken by the discharge energy. GPC results show that pPANI has high molecular weight (Mw, about 533 kDa with 1.9 polydispersity index (PDI. This study contributes to a better understanding on the novel growth process and synthesis of uniform polyaniline nanofibers and nanoparticles with high molecular weights using the simple atmospheric pressure plasma polymerization technique.

  2. Use of Atmospheric-Pressure Plasma Jet for Polymer Surface Modification: An Overview

    Energy Technology Data Exchange (ETDEWEB)

    Kuettner, Lindsey A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-16

    Atmospheric-pressure plasma jets (APPJs) are playing an increasingly important role in materials processing procedures. Plasma treatment is a useful tool to modify surface properties of materials, especially polymers. Plasma reacts with polymer surfaces in numerous ways thus the type of process gas and plasma conditions must be explored for chosen substrates and materials to maximize desired properties. This report discusses plasma treatments and looks further into atmospheric-pressure plasma jets and the effects of gases and plasma conditions. Following the short literature review, a general overview of the future work and research at Los Alamos National Laboratory (LANL) is discussed.

  3. Surface chemical changes of atmospheric pressure plasma treated rabbit fibres important for felting process

    Energy Technology Data Exchange (ETDEWEB)

    Štěpánová, Vlasta, E-mail: vstepanova@mail.muni.cz [Department of Physical Electronics, Faculty of Science Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); Slavíček, Pavel; Stupavská, Monika; Jurmanová, Jana [Department of Physical Electronics, Faculty of Science Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); Černák, Mirko [Department of Physical Electronics, Faculty of Science Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); Department of Experimental Physics, Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynská dolina F2, 842 48 Bratislava (Slovakia)

    2015-11-15

    Graphical abstract: - Highlights: • Rabbit fibres plasma treatment is an effective method for fibres modification. • Atmospheric pressure plasma treatment is able to affect fibres properties. • Surface changes on fibres after plasma treatment were analysed via SEM, ATR-FTIR, XPS. • Significant increase of fibres wettability after plasma treatment was observed. • Plasma treatment at atmospheric pressure can replace the chemical treatment of fibres. - Abstract: We introduce the atmospheric pressure plasma treatment as a suitable procedure for in-line industrial application of rabbit fibres pre-treatment. Changes of rabbit fibre properties due to the plasma treatment were studied in order to develop new technology of plasma-based treatment before felting. Diffuse Coplanar Surface Barrier Discharge (DCSBD) in ambient air at atmospheric pressure was used for plasma treatment. Scanning electron microscopy was used for determination of the fibres morphology before and after plasma treatment. X-ray photoelectron spectroscopy and attenuated total reflectance-Fourier transform infrared spectroscopy were used for evaluation of reactive groups. The concentration of carbon decreased and conversely the concentration of nitrogen and oxygen increased after plasma treatment. Aging effect of plasma treated fibres was also investigated. Using Washburn method the significant increase of fibres wettability was observed after plasma treatment. New approach of pre-treatment of fibres before felting using plasma was developed. Plasma treatment of fibres at atmospheric pressure can replace the chemical method which consists of application of strong acids on fibres.

  4. Characterizations of atmospheric pressure low temperature plasma jets and their applications

    Science.gov (United States)

    Karakas, Erdinc

    2011-12-01

    Atmospheric pressure low temperature plasma jets (APLTPJs) driven by short pulses have recently received great attention because of their potential in biomedical and environmental applications. This potential is due to their user-friendly features, such as low temperature, low risk of arcing, operation at atmospheric pressure, easy handheld operation, and low concentration of ozone generation. Recent experimental observations indicate that an ionization wave exists and propagates along the plasma jet. The plasma jet created by this ionization wave is not a continuous medium but rather consists of a bullet-like-structure known as "Plasma Bullet". More interestingly, these plasma bullets actually have a donut-shaped makeup. The nature of the plasma bullet is especially interesting because it propagates in the ambient air at supersonic velocities without any externally applied electric field. In this dissertation, experimental insights are reported regarding the physical and chemical characteristics of the APLTPJs. The dynamics of the plasma bullet are investigated by means of a high-speed ICCD camera. A plasma bullet propagation model based on the streamer theory is confirmed with adequate explanations. It is also found that a secondary discharge, ignited by the charge accumulation on the dielectric electrode surfaces at the end of the applied voltage, interrupts the plasma bullet propagation due to an opposing current along the ionization channel. The reason for this interesting phenomenon is explained in detail. The plasma bullet comes to an end when the helium mole fraction along the ionization channel, or applied voltage, or both, are less than some critical values. The presence of an inert gas channel in the surrounding air, such as helium or argon, has a critical role in plasma bullet formation and propagation. For this reason, a fluid dynamics study is employed by a commercially available simulation software, COMSOL, based on finite element method. Spatio

  5. Atmospheric Pressure Plasma Jet as a Dry Alternative to Inkjet Printing in Flexible Electronics

    Science.gov (United States)

    Gandhiraman, Ram Prasad; Lopez, Arlene; Koehne, Jessica; Meyyappan, M.

    2016-01-01

    We have developed an atmospheric pressure plasma jet printing system that works at room temperature to 50 deg C unlike conventional aerosol assisted techniques which require a high temperature sintering step to obtain desired thin films. Multiple jets can be configured to increase throughput or to deposit multiple materials, and the jet(s) can be moved across large areas using a x-y stage. The plasma jet has been used to deposit carbon nanotubes, graphene, silver nanowires, copper nanoparticles and other materials on substrates such as paper, cotton, plastic and thin metal foils.

  6. Influence of the reactive atmosphere on the formation of nanoparticles in the plasma plume induced by nanosecond pulsed laser irradiation of metallic targets at atmospheric pressure and high repetition rate

    Energy Technology Data Exchange (ETDEWEB)

    Girault, M. [Laboratoire Interdisciplinaire Carnot de Bourgogne, UMR 6303 CNRS-Univ. Bourgogne Franche-Comté, 9 Av. A. Savary, BP 47 870, F-21078 Dijon Cedex (France); Le Garrec, J.-L.; Mitchell, J.B.A. [Institut de Physique de Rennes, UMR 6251 CNRS-Université de Rennes 1, 35042 Rennes Cedex (France); Jouvard, J.-M. [Laboratoire Interdisciplinaire Carnot de Bourgogne, UMR 6303 CNRS-Univ. Bourgogne Franche-Comté, 9 Av. A. Savary, BP 47 870, F-21078 Dijon Cedex (France); Carvou, E. [Institut de Physique de Rennes, UMR 6251 CNRS-Université de Rennes 1, 35042 Rennes Cedex (France); Menneveux, J.; Yu, J. [Institut Lumière Matière, UMR5306 Université Lyon 1-CNRS, Université de Lyon, 69622 Villeurbanne Cedex (France); Ouf, F.-X. [Institut de Radioprotection et de Sureté Nucléaire IRSN/PSN-RES/SCA/LPMA BP 68, 91192 Gif-Sur-Yvette (France); Carles, S. [Institut de Physique de Rennes, UMR 6251 CNRS-Université de Rennes 1, 35042 Rennes Cedex (France); Potin, V.; Pillon, G.; Bourgeois, S. [Laboratoire Interdisciplinaire Carnot de Bourgogne, UMR 6303 CNRS-Univ. Bourgogne Franche-Comté, 9 Av. A. Savary, BP 47 870, F-21078 Dijon Cedex (France); Perez, J. [Synchrotron SOLEIL, L’Orme des Merisiers, Saint-Aubin, F-91192 Gif-sur-Yvette Cedex (France); Marco de Lucas, M.C., E-mail: delucas@u-bourgogne.fr [Laboratoire Interdisciplinaire Carnot de Bourgogne, UMR 6303 CNRS-Univ. Bourgogne Franche-Comté, 9 Av. A. Savary, BP 47 870, F-21078 Dijon Cedex (France); and others

    2016-06-30

    Highlights: • NPs formed in a plasma-plume during laser irradiation of metals (Al, Ti, Ag) were studied. • In situ SAXS and ex situ TEM, XRD and Raman spectra were measured. • NPs size decreased when increasing the O{sub 2} fraction in a controlled O{sub 2}+N{sub 2} atmosphere. • The oxidation of metal NPs in the plasma restricts the increase of the size of the NPs. - Abstract: The influence of a reactive atmosphere on the formation of nanoparticles (NPs) in the plasma plume generated by nanosecond pulsed laser irradiation of metal targets (Ti, Al, Ag) was probed in situ using Small Angle X-ray Scattering (SAXS). Air and different O{sub 2}–N{sub 2} gas mixtures were used as reactive gas within atmospheric pressure. SAXS results showed the formation of NPs in the plasma-plume with a mean radius varying in the 2–5 nm range. A decrease of the NPs size with increasing the O{sub 2} percentage in the O{sub 2}–N{sub 2} gas mixture was also showed. Ex situ observations by transmission electron microscopy and structural characterizations by X-ray diffraction and Raman spectroscopy were also performed for powders collected in experiments done using air as ambient gas. The stability of the different metal oxides is discussed as being a key parameter influencing the formation of NPs in the plasma-plume.

  7. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... blood pressure, you may need to restrict your sodium intake even more. Your health care provider may recommend the Dietary Approaches to ... heart healthy and low in fat, cholesterol, and salt. The DASH eating plan is ... Eating Your health care provider also may recommend heart-healthy eating, ...

  8. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Related Topics Atherosclerosis DASH Eating Plan Overweight and Obesity Smoking and Your Heart Stroke Send a link ... are consistently higher than 120/80 mmHg. Your child’s blood pressure numbers are outside average numbers for ...

  9. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... and Strategic Vision Leadership Scientific Divisions Operations and Administration Advisory Committees Budget and Legislative Information Jobs and ... With DASH My Blood Pressure Wallet Card Other Resources Cigarette and Tobacco Facts (National Institute on Drug ... OIG USA.gov

  10. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... blood pressure. The DASH eating plan focuses on fruits, vegetables, whole grains, and other foods that are heart ... heart-healthy eating, which should include: Whole grains Fruits, such as apples, bananas, oranges, pears, and prunes Vegetables, such as broccoli, cabbage, and carrots Legumes, such ...

  11. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... lead to cognitive changes. Signs and symptoms include memory loss, difficulty finding words, and losing focus during ... are consistently higher than 120/80 mmHg. Your child’s blood pressure numbers are outside average numbers for ...

  12. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... bleed. Signs and symptoms include vision changes or blindness. Heart Attack : When the flow of oxygen-rich ... are consistently higher than 120/80 mmHg. Your child’s blood pressure numbers are outside average numbers for ...

  13. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... healthy diet. Be physically active. Maintain a healthy weight. Limit alcohol intake. Other lifestyle changes can improve your overall health, such as: If you smoke , quit. Get plenty of sleep. Drink more water. Medicines Take all blood pressure ...

  14. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... to develop your treatment plan. Some people have “white coat hypertension.” This happens when blood pressure readings ... which can occur during the medical appointment, causes white coat hypertension. Treatment Based on your diagnosis, health ...

  15. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Health Topics Health Topics A-Z Clinical Trials Publications and Resources Health Education and Awareness The Science ... are consistently higher than 120/80 mmHg. Your child’s blood pressure numbers are outside average numbers for ...

  16. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... are heart healthy. Limiting Sodium and Salt A low-sodium diet can help you manage your blood pressure. ... lower in salt and sodium. Try to use low-sodium and “no added salt” foods and seasonings at ...

  17. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... other health problems. If you’re overweight or obese, try to lose weight. A loss of just 3 to 5 percent can lower ... risk for health problems. Greater amounts of weight loss can improve blood pressure readings, lower ... to maintain good health. A useful measure of overweight and obesity is body mass index (BMI). BMI measures your ...

  18. Ambulatory pulmonary arterial pressure in primary pulmonary hypertension: variability, relation to systemic arterial pressure, and plasma catecholamines.

    OpenAIRE

    Richards, A M; Ikram, H; Crozier, I G; Nicholls, M G; Jans, S

    1990-01-01

    The variability of pulmonary arterial pressure, the relation of pulmonary pressure to systemic pressure, pulmonary pressure responses to stimuli (exercise, hypoxia, smoking, free ambulation), and plasma catecholamine responses were assessed in five patients with primary pulmonary hypertension. Ambulatory monitoring techniques provided data for the computerised analysis of continuous, beat-to-beat, direct recordings of both pulmonary and systemic arterial pressures for 8 to 10 hours. The absol...

  19. Excitation and Ionisation dynamics in high-frequency plasmas

    Science.gov (United States)

    O'Connell, D.

    2008-07-01

    Non-thermal low temperature plasmas are widely used for technological applications. Increased demands on plasma technology have resulted in the development of various discharge concepts based on different power coupling mechanisms. Despite this, power dissipation mechanisms in these discharges are not yet fully understood. Of particular interest are low pressure radio-frequency (rf) discharges. The limited understanding of these discharges is predominantly due to the complexity of the underlying mechanisms and difficult diagnostic access to important parameters. Optical measurements are a powerful diagnostic tool offering high spatial and temporal resolution. Optical emission spectroscopy (OES) provides non-intrusive access, to the physics of the plasma, with comparatively simple experimental requirements. Improved advances in technology and modern diagnostics now allow deeper insight into fundamental mechanisms. In low pressure rf discharges insight into the electron dynamics within the rf cycle can yield vital information. This requires high temporal resolution on a nano-second time scale. The optical emission from rf discharges exhibits temporal variations within the rf cycle. These variations are particularly strong, in for example capacitively coupled plasmas (CCPs), but also easily observable in inductively coupled plasmas (ICPs), and can be exploited for insight into power dissipation. Interesting kinetic and non-linear coupling effects are revealed in capacitive systems. The electron dynamics exhibits a complex spatio-temporal structure. Excitation and ionisation, and, therefore, plasma sustainment is dominated through directed energetic electrons created through the dynamics of the plasma boundary sheath. In the relatively simple case of an asymmetric capacitively coupled rf plasma the complexity of the power dissipation is exposed and various mode transitions can be clearly observed and investigated. At higher pressure secondary electrons dominate the

  20. Gene Transfection Method Using Atmospheric Pressure Dielectric-Barrier Discharge Plasmas

    Science.gov (United States)

    Sasaki, Shota; Kanzaki, Makoto; Kaneko, Toshiro

    2013-09-01

    Gene transfection which is the process of deliberately introducing nucleic acids into cells is expected to play an important role in medical treatment because the process is necessary for gene therapy and creation of induced pluripotent stem (iPS) cells. However, the conventional transfection methods have some problems, so we focus attention on promising transfection methods by atmospheric pressure dielectric-barrier discharge (AP-DBD) plasmas. AP-DBD He plasmas are irradiated to the living cell covered with genes. Preliminarily, we use fluorescent dye YOYO-1 instead of the genes and use LIVE/DEAD Stain for cell viability test, and we analyze the transfection efficiency and cell viability under the various conditions. It is clarified that the transfection efficiency is strongly dependence on the plasma irradiation time and cell viability rates is high rates (>90%) regardless of long plasma irradiation time. These results suggest that ROS (Reactive Oxygen Species) and electric field generated by the plasma affect the gene transfection. In addition to this (the plasma irradiation time) dependency, we now investigate the effect of the plasma irradiation under the various conditions.

  1. Radiation from High Temperature Plasmas.

    Science.gov (United States)

    1980-09-09

    PERFORMING ORGANIZATION NAME AND ADDRESS IO7PUOAM i. .’- "--"--o TASK AREA & WORK UNIT NUMIERS SI I. CONTROLLING OFFICE NAME AND ADDRESS .... D...8217’ -REPORT OATM September 19 14. MONITOING AGENCY NAME & AOORESS(I! dilfl ,rn lm Controlling Office) IS. SECURITY CLASS. (of tli repot) Unclassified 1S...together (specifically 25-50 X, in aluminum) id show comparable intensities is an indicatiou oE a rather substantial temperatura aradient in the plasma

  2. Minimally-Invasive Gene Transfection by Chemical and Physical Interaction of Atmospheric Pressure Plasma Flow

    Science.gov (United States)

    Kaneko, Toshiro

    2014-10-01

    Non-equilibrium atmospheric pressure plasma irradiated to the living-cell is investigated for medical applications such as gene transfection, which is expected to play an important role in molecular biology, gene therapy, and creation of induced pluripotent stem (iPS) cells. However, the conventional gene transfection using the plasma has some problems that the cell viability is low and the genes cannot be transferred into some specific lipid cells, which is attributed to the unknown mechanism of the gene transfection using the plasma. Therefore, the time-controlled atmospheric pressure plasma flow is generated and irradiated to the living-cell suspended solution for clarifying the transfection mechanism toward developing highly-efficient and minimally- invasive gene transfection system. In this experiment, fluorescent dye YOYO-1 is used as the simulated gene and LIVE/DEAD Stain is simultaneously used for cell viability assay. By the fluorescence image, the transfection efficiency is calculated as the ratio of the number of transferred and surviving cells to total cell count. It is clarified that the transfection efficiency is significantly increased by the short-time (90%). This result indicates that the physical effects such as the electric field caused by the charged particles arriving at the surface of the cell membrane, and chemical effects associated with plasma-activated products in solution act synergistically to enhance the cell-membrane transport with low-damage. This work was supported by JSPS KAKENHI Grant Number 24108004.

  3. High-pressure, flux-conserving tokamak equilibria

    Energy Technology Data Exchange (ETDEWEB)

    Dory, R.A.; Peng, Y.K.M.

    1976-08-01

    Magnetohydrodynamic (MHD) tokamak equilibria are found with values of ..beta.. up to 20 percent and prescribed MHD safety factor values (e.g., q(axis) = 1 and q(edge) = 4.8) for tokamaks with aspect ratio A = 4 and D-shaped cross section. If such equilibria could be attained experimentally, they would be very attractive for decreasing the projected costs of tokamak power reactors substantially. In the flux-conserving tokamak (FCT) model, where rapid heating is applied to an already relatively hot plasma, these high ..beta.. equilibria are achievable. We study the quasi-static evolution of FCT equilibria as ..beta.. increases. An operating window is found in the pressure profile width w/sub p/: for high ..beta.. the values of w/sub p/ must lie between 0.40 and 0.55 of the plasma minor width. Within this window, plasma current and poloidal ..beta.. increase monotonically with ..beta... For fixed plasma boundary, significant poloidal surface currents are induced, but these can be eliminated by small increases in the plasma minor radius, the pressure profile width, and the vacuum toroidal field.

  4. Energy Density in Aligned Nanowire Arrays Irradiated with Relativistic Intensities: Path to Terabar Pressure Plasmas

    Science.gov (United States)

    Rocca, J.; Bargsten, C.; Hollinger, R.; Shylaptsev, V.; Wang, S.; Rockwood, A.; Wang, Y.; Keiss, D.; Capeluto, M.; Kaymak, V.; Pukhov, A.; Tommasini, R.; London, R.; Park, J.

    2016-10-01

    Ultra-high-energy-density (UHED) plasmas, characterized by energy densities >1 x 108 J cm-3 and pressures greater than a gigabar are encountered in the center of stars and in inertial confinement fusion capsules driven by the world's largest lasers. Similar conditions can be obtained with compact, ultra-high contrast, femtosecond lasers focused to relativistic intensities onto aligned nanowire array targets. Here we report the measurement of the key physical process in determining the energy density deposited in high aspect ratio nanowire array plasmas: the energy penetration. By monitoring the x-ray emission from buried Co tracer segments in Ni nanowire arrays irradiated at an intensity of 4 x 1019 W cm-2, we demonstrate energy penetration depths of several μm, leading to UHED plasmas of that size. Relativistic 3D particle-in-cell-simulations validated by these measurements predict that irradiation of nanostructures at increased intensity will lead to a virtually unexplored extreme UHED plasma regime characterized by energy densities in excess of 8 x 1010 J cm-3, equivalent to a pressure of 0.35 Tbar. This work was supported by the Fusion Energy Program, Office of Science of the U.S Department of Energy, and by the Defense Threat Reduction Agency.

  5. High-Intensity Plasma Glass Melter

    Energy Technology Data Exchange (ETDEWEB)

    None

    2004-01-01

    Modular high-intensity plasma melter promises improved performance, reduced energy use, and lower emissions. The glass industry has used the same basic equipment for melting glass for the past 100 years.

  6. High Power Helicon Plasma Propulsion Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed work seeks to develop and optimize an electrode-less plasma propulsion system that is based on a high power helicon (HPH) that is being developed...

  7. High Power Helicon Plasma Propulsion Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A new thruster has been conceived and tested that is based on a high power helicon (HPH) plasma wave. In this new method of propulsion, an antenna generates and...

  8. Use of Atmospheric Pressure Cold Plasma for Meat Industry.

    Science.gov (United States)

    Lee, Juri; Lee, Cheol Woo; Yong, Hae In; Lee, Hyun Jung; Jo, Cheorun; Jung, Samooel

    2017-01-01

    Novel, effective methods to control and prevent spoilage and contamination by pathogenic microorganisms in meat and meat products are in constant demand. Non-thermal pasteurization is an ideal method for the preservation of meat and meat products because it does not use heat during the pasteurization process. Atmospheric pressure cold plasma (APCP) is a new technology for the non-thermal pasteurization of meat and meat products. Several recent studies have shown that APCP treatment reduces the number of pathogenic microorganisms in meat and meat products. Furthermore, APCP treatment can be used to generate nitrite, which is an essential component of the curing process. Here, we introduce the effectiveness of APCP treatment as a pasteurization method and/or curing process for use in the meat and meat product processing industry.

  9. High Power Argon, Nitrogen Plasma Torches

    Science.gov (United States)

    Hakki, A.; Kashapov, N.; Sadikov, K.

    2017-11-01

    The paper describes a high power supply for Argon and Nitrogen plasma torches. A high frequency was used in order to drive the pulse width modulation circuit. The average output current consumption (AOCC) was modified from 20A up to 80A by increasing the pulse width from 2μsec up to 3μsec for Argon gas plasma torches. The (AOCC) was reduced from 70A down to 25A by increasing the pulse width from 6μsec up to 8μsec in the case of Nitrogen gas plasma torches.

  10. High pressure studies of molecular lumenescence

    Energy Technology Data Exchange (ETDEWEB)

    Drickamer, H.G.

    1982-01-01

    The studies of high pressure molecular luminescence reviewed, along with results for inorganic systems discussed elsewhere, provide evidence about the versatility and power of high pressure as a tool for characterizing electronic states, testing theories concerning electronic phenomena, and generally obtaining a better understanding of electronic behavior in condensed systems. 16 figures.

  11. Coal swelling and thermoplasticity under high pressure

    Energy Technology Data Exchange (ETDEWEB)

    Ndaji, F.E.; Butterfield, I.M.; Thomas, K.M. (Newcastle upon Tyne University, Newcastle upon Tyne (United Kingdom). Northern Carbon Research Labs., Dept. of Chemistry)

    1992-01-01

    The literature on the following topics is reviewed: swelling and agglomeration of coal; measurements of swelling index and dilatometric and plastometric properties at high pressures; and the effects of oxidation, tar addition and minerals on high-pressure thermoplastic properties. 34 refs., 6 figs.

  12. Application of High Pressure in Food Processing

    Directory of Open Access Journals (Sweden)

    Herceg, Z.

    2011-01-01

    Full Text Available In high pressure processing, foods are subjected to pressures generally in the range of 100 – 800 (1200 MPa. The processing temperature during pressure treatments can be adjusted from below 0 °C to above 100 °C, with exposure times ranging from a few seconds to 20 minutes and even longer, depending on process conditions. The effects of high pressure are system volume reduction and acceleration of reactions that lead to volume reduction. The main areas of interest regarding high-pressure processing of food include: inactivation of microorganisms, modification of biopolymers, quality retention (especially in terms of flavour and colour, and changes in product functionality. Food components responsible for the nutritive value and sensory properties of food remain unaffected by high pressure. Based on the theoretical background of high-pressure processing and taking into account its advantages and limitations, this paper aims to show its possible application in food processing. The paper gives an outline of the special equipment used in highpressure processing. Typical high pressure equipment in which pressure can be generated either by direct or indirect compression are presented together with three major types of high pressure food processing: the conventional (batch system, semicontinuous and continuous systems. In addition to looking at this technology’s ability to inactivate microorganisms at room temperature, which makes it the ultimate alternative to thermal treatments, this paper also explores its application in dairy, meat, fruit and vegetable processing. Here presented are the effects of high-pressure treatment in milk and dairy processing on the inactivation of microorganisms and the modification of milk protein, which has a major impact on rennet coagulation and curd formation properties of treated milk. The possible application of this treatment in controlling cheese manufacture, ripening and safety is discussed. The opportunities

  13. A High Temperature Liquid Plasma Model of the Sun

    Directory of Open Access Journals (Sweden)

    Robitaille P.-M.

    2007-01-01

    Full Text Available In this work, a liquid model of the Sun is presented wherein the entire solar mass is viewed as a high density/high energy plasma. This model challenges our current understanding of the densities associated with the internal layers of the Sun, advocating a relatively constant density, almost independent of radial position. The incompressible nature of liquids is advanced to prevent solar collapse from gravitational forces. The liquid plasma model of the Sun is a non-equilibrium approach, where nuclear reactions occur throughout the solar mass. The primary means of addressing internal heat transfer are convection and conduction. As a result of the convective processes on the solar surface, the liquid model brings into question the established temperature of the solar photosphere by highlighting a violation of Kirchhoff’s law of thermal emission. Along these lines, the model also emphasizes that radiative emission is a surface phenomenon. Evidence that the Sun is a high density/high energy plasma is based on our knowledge of Planckian thermal emission and condensed matter, including the existence of pressure ionization and liquid metallic hydrogen at high temperatures and pressures. Prior to introducing the liquid plasma model, the historic and scientific justifications for the gaseous model of the Sun are reviewed and the gaseous equations of state are also discussed.

  14. The solvation of electrons by an atmospheric-pressure plasma

    Science.gov (United States)

    Rumbach, Paul; Bartels, David M.; Sankaran, R. Mohan; Go, David B.

    2015-01-01

    Solvated electrons are typically generated by radiolysis or photoionization of solutes. While plasmas containing free electrons have been brought into contact with liquids in studies dating back centuries, there has been little evidence that electrons are solvated by this approach. Here we report direct measurements of solvated electrons generated by an atmospheric-pressure plasma in contact with the surface of an aqueous solution. The electrons are measured by their optical absorbance using a total internal reflection geometry. The measured absorption spectrum is unexpectedly blue shifted, which is potentially due to the intense electric field in the interfacial Debye layer. We estimate an average penetration depth of 2.5±1.0 nm, indicating that the electrons fully solvate before reacting through second-order recombination. Reactions with various electron scavengers including H+, NO2−, NO3− and H2O2 show that the kinetics are similar, but not identical, to those for solvated electrons formed in bulk water by radiolysis. PMID:26088017

  15. High pressure processing for food safety.

    Science.gov (United States)

    Fonberg-Broczek, Monika; Windyga, B; Szczawiński, J; Szczawińska, M; Pietrzak, D; Prestamo, G

    2005-01-01

    Food preservation using high pressure is a promising technique in food industry as it offers numerous opportunities for developing new foods with extended shelf-life, high nutritional value and excellent organoleptic characteristics. High pressure is an alternative to thermal processing. The resistance of microorganisms to pressure varies considerably depending on the pressure range applied, temperature and treatment duration, and type of microorganism. Generally, Gram-positive bacteria are more resistant to pressure than Gram-negative bacteria, moulds and yeasts; the most resistant are bacterial spores. The nature of the food is also important, as it may contain substances which protect the microorganism from high pressure. This article presents results of our studies involving the effect of high pressure on survival of some pathogenic bacteria -- Listeria monocytogenes, Aeromonas hydrophila and Enterococcus hirae -- in artificially contaminated cooked ham, ripening hard cheese and fruit juices. The results indicate that in samples of investigated foods the number of these microorganisms decreased proportionally to the pressure used and the duration of treatment, and the effect of these two factors was statistically significant (level of probability, P monocytogenes and A. hydrophila. Mathematical methods were applied, for accurate prediction of the effects of high pressure on microorganisms. The usefulness of high pressure treatment for inactivation of microorganisms and shelf-life extention of meat products was also evaluated. The results obtained show that high pressure treatment extends the shelf-life of cooked pork ham and raw smoked pork loin up to 8 weeks, ensuring good micro-biological and sensory quality of the products.

  16. State of the art in medical applications using non-thermal atmospheric pressure plasma

    Science.gov (United States)

    Tanaka, Hiromasa; Ishikawa, Kenji; Mizuno, Masaaki; Toyokuni, Shinya; Kajiyama, Hiroaki; Kikkawa, Fumitaka; Metelmann, Hans-Robert; Hori, Masaru

    2017-12-01

    Plasma medical science is a novel interdisciplinary field that combines studies on plasma science and medical science, with the anticipation that understanding the scientific principles governing plasma medical science will lead to innovations in the field. Non-thermal atmospheric pressure plasma has been used for medical treatments, such as for cancer, blood coagulation, and wound healing. The interactions that occur between plasma and cells/tissues have been analyzed extensively. Direct and indirect treatment of cells with plasma has broadened the applications of non-thermal atmospheric pressure plasma in medicine. Examples of indirect treatment include plasma-assisted immune-therapy and plasma-activated medium. Controlling intracellular redox balance may be key in plasma cancer treatment. Animal studies are required to test the effectiveness and safety of these treatments for future clinical applications.

  17. Techniques in high pressure neutron scattering

    CERN Document Server

    Klotz, Stefan

    2013-01-01

    Drawing on the author's practical work from the last 20 years, Techniques in High Pressure Neutron Scattering is one of the first books to gather recent methods that allow neutron scattering well beyond 10 GPa. The author shows how neutron scattering has to be adapted to the pressure range and type of measurement.Suitable for both newcomers and experienced high pressure scientists and engineers, the book describes various solutions spanning two to three orders of magnitude in pressure that have emerged in the past three decades. Many engineering concepts are illustrated through examples of rea

  18. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... high. Causes Changes, either from genes or the environment, in the body’s normal functions may cause high ... ounces of liquor Managing and Coping With Stress Learning how to manage stress, relax, and cope with ...

  19. Multi-electrodes Atmospheric Pressure Plasma Jet Aiming Bio-applications

    Science.gov (United States)

    Han, Jeon G.; Sahu, B. B.; Shin, K. S.; Lee, J. S.; Hori, M.

    2015-09-01

    For the recent advancement in the field of plasma medicine, there is growing demand for the atmospheric-pressure plasma (APP) jet sources with desired plasma characteristics. In this study, a stable non-thermal low-voltage APP jet device was designed and developed for optical and electrical characterizations. The jet was operated at very low frequency in the range 10-40 KHz, which enabled the generation of low power (~ 7W) plasma with a plasma column diameter of about 5 mm. The jet has a visible radial diameter of approximately 10 mm. Optical emission spectroscopy was used as a diagnostic tool to investigate the generation of plasmas and radical species. Discharge parameters are also measured to evaluate the different operating conditions. The gas temperature measured at the substrate location varies from 300 to 315 K for different gases where the electrical input power ranged from 1 to 7 W. The highly reactive species like OH, O, N2, N2 + and along with the trace of NO are characterized with respect to the different gas flow rate of Ar/He/O2/N2, applied voltages, duty cycles and frequencies to evaluate the capability of the APP jet for future bio-applications.

  20. Micro-Biocidal Activity of Yeast Cells by Needle Plasma Irradiation at Atmospheric Pressure

    Science.gov (United States)

    Kurumi, Satoshi; Takahashi, Hideyuki; Taima, Tomohito; Suzuki, Kaoru; Hirose, Hideharu; Masutani, Shigeyuki

    In this study, we report on the biocidal activity technique by needle helium plasma irradiation at atmospheric pressure using borosilicate capillary nozzle to apply for the oral surgery. The diameter of needle plasma was less than 50 µm, and temperature of plasma irradiated area was less than body temperature. Needle plasma showed emission due to OH and O radical. Raman spectra and methylene blue stain showed yeast cells were inactivated by needle plasma irradiation.

  1. High Pressure Supersonic Gas Jet Fueling on NSTX

    Energy Technology Data Exchange (ETDEWEB)

    Soukhanovskii, V; Bell, M; Blanchard, W; Dong, J; Gernhardt, R; Kaita, R; Kugel, H; Provost, T; Roquemore, A; Sichta, P

    2007-06-25

    A supersonic gas injector (SGI) has been developed for fueling and diagnostic applications on NSTX. The SGI is comprised of a small de Laval converging-diverging graphite nozzle, a commercial piezoelectric gas valve, and a diagnostic package, all mounted on a movable probe at a low field side midplane port location. The nozzle operated in a pulsed regime at room temperature, reservoir deuterium pressure up to 2500 Torr (50 PSIA), flow rate up to 65 Torr l /s (4.55e21 particles/s), and a measured Mach number of about 4. In initial experiments the SGI was used for fueling of ohmic and 2 - 6 MW NBI-heated L- and H-mode plasmas. Reliable H-mode access was obtained with SGI fueling, with a fueling efficiency in the range 0.1 - 0.3. Good progress was also made toward a controlled density SGI-fueled H-mode plasma scenario with the flow rate of the uncontrolled high field side (HFS) gas injector reduced by up to 20. These experiments motivated a number of SGI upgrades: (1) the maximum plenum pressure has been increased to 5000 Torr (100 PSIA), (2) the plenum pressure volume has been doubled, (3) the gas delivery system has been changed to allow for injection of various gases, (4) a multi-pulse capability has been implemented. As a result of the upgrades, the maximum flow rate increased to about 130 Torr l /s. Laboratory gas jet characterization tests indicated a Mach number of about 4 with H2 and D2, and 4-6 with He and N2. Plasma experiments demonstrated the high-pressure gas jet fueling compatibility with H-mode plasmas, high fueling efficiency (0.1 - 0.3), and high SOL penetration.

  2. High-pressure minerals in shocked meteorites

    Science.gov (United States)

    Tomioka, Naotaka; Miyahara, Masaaki

    2017-09-01

    Heavily shocked meteorites contain various types of high-pressure polymorphs of major minerals (olivine, pyroxene, feldspar, and quartz) and accessory minerals (chromite and Ca phosphate). These high-pressure minerals are micron to submicron sized and occur within and in the vicinity of shock-induced melt veins and melt pockets in chondrites and lunar, howardite-eucrite-diogenite (HED), and Martian meteorites. Their occurrence suggests two types of formation mechanisms (1) solid-state high-pressure transformation of the host-rock minerals into monomineralic polycrystalline aggregates, and (2) crystallization of chondritic or monomineralic melts under high pressure. Based on experimentally determined phase relations, their formation pressures are limited to the pressure range up to 25 GPa. Textural, crystallographic, and chemical characteristics of high-pressure minerals provide clues about the impact events of meteorite parent bodies, including their size and mutual collision velocities and about the mineralogy of deep planetary interiors. The aim of this article is to review and summarize the findings on natural high-pressure minerals in shocked meteorites that have been reported over the past 50 years.

  3. Low pressure plasma discharges for the sterilization and decontamination of surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, F; Rauscher, H; Hasiwa, M; Gilliland, D [European Commission, Joint Research Centre, Institute for Health and Consumer Protection, Via E. Fermi 2749, 21027 Ispra (Vatican City State, Holy See) (Italy); Kylian, O [Faculty of Mathematics and Physics, Charles University, V Holesovickach 2, Prague 8, 180 00 (Czech Republic)], E-mail: francois.rossi@jrc.ec.europa.eu

    2009-11-15

    The mechanisms of sterilization and decontamination of surfaces are compared in direct and post discharge plasma treatments in two low-pressure reactors, microwave and inductively coupled plasma. It is shown that the removal of various biomolecules, such as proteins, pyrogens or peptides, can be obtained at high rates and low temperatures in the inductively coupled plasma (ICP) by using Ar/O{sub 2} mixtures. Similar efficiency is obtained for bacterial spores. Analysis of the discharge conditions illustrates the role of ion bombardment associated with O radicals, leading to a fast etching of organic matter. By contrast, the conditions obtained in the post discharge lead to much lower etching rates but also to a chemical modification of pyrogens, leading to their de-activation. The advantages of the two processes are discussed for the application to the practical case of decontamination of medical devices and reduction of hospital infections, illustrating the advantages and drawbacks of the two approaches.

  4. Characteristics of plasma sterilizer using microwave torch plasma with AC high-voltage discharge plasma

    Science.gov (United States)

    Itarashiki, Tomomasa; Hayashi, Nobuya; Yonesu, Akira

    2016-01-01

    Microwave plasma sterilization has recently been attracting attention for medical applications. However, it is difficult to perform low-temperature sterilization in short time periods. Increasing the output power shortens the time required for sterilization but causes the temperature to increase. To overcome this issue, we have developed a hybrid plasma system that combines a microwave torch plasma and a high-voltage mesh plasma, which allows radicals to be produced at low temperatures. Using this system, successful sterilization was shown to be possible in a period of 45 min at a temperature of 41 °C.

  5. Cementing liners through deep high pressure ones

    Energy Technology Data Exchange (ETDEWEB)

    Mahony, B.J.; Barrios, J.R.

    1974-03-01

    Entry of gas into the liner-hole annulus during and after cementing liners though deep high pressure zones, generally results in a gas cut cement column from depth of gas entry to top of liner. Prior to undertaking design of liner cementation, it is necessary to know fracture pressure limits of the formations. It is also necessary to know the formation pore pressure or the pressure required to hold gas in the formation and precisely the depth of formation from which gas emerges. This knowledge may be gained from a study of formation pressure gradients of nearby wells or from sonic log analysis of the interval being readied for cementation. Both single-stage and 2-stage techniques are used to solve liner cementing problems in these high pressure zones. An example sets out conditions which are more or less typical and demonstrates how the problem may be considered and solved.

  6. Helicon wave propagation and plasma equilibrium in high-density hydrogen plasma in converging magnetic fields

    Science.gov (United States)

    Caneses Marin, Juan Francisco

    Braginskii” type formalism shows that the electron fluid exists in a state of dynamic (flowing) equilibrium between the electric, pressure and thermal forces. The pressure gradient, driven by the non-uniform RF heating, accelerates the plasma into the target region to velocities close to the ion sound speed. From the measured axial plasma flux we find that the plasma column in MAGPIE can be divided into an ionizing and a recombining region. For the conditions investigated, a large fraction of the plasma created in the ionizing region is lost in the recombining region and only a small fraction reaches the end of the device. The equilibrium plasma density along the length of MAGPIE can be quantitatively explained using a 1D transport calculation which includes volumetric particle sources and magnetic compression. We show that the plasma is transported, by the electron pressure gradient, from under the antenna (0.5x10. 19 m-3) into the target region where it reaches maximum density (2-3x10. 19 m-3). Using the results herein presented, this thesis explores the relationship between the RF power deposition in MAGPIE, parallel plasma transport and the production of high density plasma in the target region.

  7. Unified one-dimensional model of bounded plasma with nonzero ion temperature in a broad pressure range

    Energy Technology Data Exchange (ETDEWEB)

    Palacio Mizrahi, J. H.; Gurovich, V. Tz.; Krasik, Ya. E. [Physics Department, Technion, Haifa 32000 (Israel)

    2013-03-15

    A one-dimensional model for steady state plasmas bounded either between large parallel walls, or by a cylinder or a sphere, valid in a wide range of gas pressures, is considered. The model includes nonzero ion temperature, inertial terms in the ion momentum equations, and allows one to calculate the plasma electron temperature and ion current density reaching the wall, as well as the spatial distributions of the ion fluid velocity, plasma density, and plasma potential in the plasma bulk. In addition, the effect of electron inertia is analyzed. The model includes as particular cases several earlier models that were based on a similar set of differential equations, but that are restricted to a specific pressure regime (low, intermediate, or high). Analytical solution is found in planar geometry, and numerical solution is given in cylindrical and spherical geometry. The results obtained are compared with those of earlier models and the differences are analyzed.

  8. High pressure layered structure of carbon disulfide

    OpenAIRE

    Naghavi, S. Shahab; Crespo, Yanier; Martonak, Roman; Tosatti, Erio

    2015-01-01

    Solid CS$_{2}$ is superficially similar to CO$_{2}$, with the same $Cmca$ molecular crystal structure at low pressures, which has suggested similar phases also at high pressures. We carried out an extensive first principles evolutionary search in order to identify the zero temperature lowest enthalpy structures of CS$_{2}$ for increasing pressure up to 200\\,GPa. Surprisingly, the molecular $Cmca$ phase does not evolve into $\\beta$-cristobalite as in CO$_{2}$, but transforms instead into phase...

  9. High Accuracy, Miniature Pressure Sensor for Very High Temperatures Project

    Data.gov (United States)

    National Aeronautics and Space Administration — SiWave proposes to develop a compact, low-cost MEMS-based pressure sensor for very high temperatures and low pressures in hypersonic wind tunnels. Most currently...

  10. CRRT Connected to ECMO: Managing High Pressures.

    Science.gov (United States)

    de Tymowski, Christian; Augustin, Pascal; Houissa, Hamda; Allou, Nicolas; Montravers, Philippe; Delzongle, Alienor; Pellenc, Quentin; Desmard, Mathieu

    Metabolic disorders and fluid overload are indications of continuous renal replacement therapy (CRRT) including continuous venovenous hemofiltration in patients on extracorporeal membrane oxygenation (ECMO). Direct connection of CRRT machine to the ECMO circuit provides many advantages. Nevertheless, because pressures in CRRT lines relate to ECMO blood flow, high ECMO blood flow may be associated with high pressures in CRRT lines. Thus, management of CRRT pressure lines becomes challenging. We evaluated a protocol for managing high CRRT pressures. Connections were performed according to a standardized protocol to maintain CRRT lines in the correct pressure ranges without modifying ECMO settings or inhibiting pressure alarms. To achieve this goal, the way of connecting of CRRT lines was adapted following a standardized protocol. Connection was first attempted between pump and oxygenator in the 12 patients. In five cases, high pressures in CRRT lines were successfully managed by changing the connection segment. Continuous renal replacement therapy parameters were within target levels and reduction of serum creatinine was 37%. In conclusion, management of high pressures in CRRT lines induced by ECMO could be achieved without modifying ECMO blood flow or inhibiting CRRT alarms. Iterative stops were avoided allowing efficient procedures.

  11. A Coupled Plasma and Sheath Model for High Density Reactors

    Science.gov (United States)

    Deepak, Bose; Govindan, T. R.; Meyyappan, M.; Arnold, Jim (Technical Monitor)

    2001-01-01

    We present a coupled plasma and collisionless; sheath model for the simulation of high density plasma processing reactors. Due to inefficiencies in numerical schemes and the resulting computational burden, a coupled multidimensional plasma and sheath simulation has not been possible model for gas mixtures and high density reactors of practical interest. In this work we demonstrate that with a fully implicit algorithm and a refined computational mesh, a self-consistent plasma and sheath simulation is feasible. We discuss the details of the model equations, the importance of ion inertia, and the resulting sheath profiles for argon and chlorine plasmas. We find that at low operating pressures (10-30 mTorr), the charge separation occurs only within a 0.5 mm layer near the surface in a 300 mm inductively coupled plasma etch reactor. A unified model eliminates the use of off-line or loosely coupled sheath models with simplifying assumptions which generally lead to uncertainties in ion flux and sheath electrical properties.

  12. Theory and simulation of anode spots in low pressure plasmas

    Science.gov (United States)

    Scheiner, Brett; Barnat, Edward V.; Baalrud, Scott D.; Hopkins, Matthew M.; Yee, Benjamin T.

    2017-11-01

    When electrodes are biased above the plasma potential, electrons accelerated through the associated electron sheath can dramatically increase the ionization rate of neutrals near the electrode surface. It has previously been observed that if the ionization rate is great enough, a double layer separates a luminous high-potential plasma attached to the electrode surface (called an anode spot or fireball) from the bulk plasma. Here, results of the first 2D particle-in-cell simulations of anode spot formation are presented along with a theoretical model describing the formation process. It is found that ionization leads to the build-up of an ion-rich layer adjacent to the electrode, forming a narrow potential well near the electrode surface that traps electrons born from ionization. It is shown that anode spot onset occurs when a quasineutral region is established in the potential well and the density in this region becomes large enough to violate the steady-state Langmuir condition, which is a balance between electron and ion fluxes across the double layer. A model for steady-state properties of the anode spot is also presented, which predicts values for the anode spot size, double layer potential drop, and form of the sheath at the electrode by considering particle, power, and current balance. These predictions are found to be consistent with the presented simulation and previous experiments.

  13. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... balances, cause your blood vessels to constrict, or impact the renin-angiotensin-aldosterone system leading to high ... two or more medicines. If you have side effects from your medicines, don’t stop taking your ...

  14. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... have any short-term serious illnesses. People with diabetes or chronic kidney disease should keep their blood ... higher risk for heart disease and type 2 diabetes. This risk may be high with a waist ...

  15. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... balances, cause your blood vessels to constrict, or impact the renin-angiotensin-aldosterone system leading to high ... are heart healthy. Limiting Sodium and Salt A low-sodium diet can help you manage your blood ...

  16. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Guidelines Funding Opportunities and Contacts Training and Career Development News and Events News and Events Home Email ... research suggests that certain DNA changes during fetal development also may cause the development of high blood ...

  17. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Genetic causes of this condition are why family history is a risk factor for this condition. Screening and Prevention Healthy lifestyle habits, proper use of medicines, and regular medical care can prevent high blood ...

  18. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... management techniques include: Being physically active Listening to music or focusing on something calm or peaceful Performing ... multidisciplinary researchers on June 10, 2016, to share current scientific k... View all events on High Blood ...

  19. Foaming Glass Using High Pressure Sintering

    DEFF Research Database (Denmark)

    Østergaard, Martin Bonderup; Petersen, Rasmus Rosenlund; König, Jakob

    Foam glass is a high added value product which contributes to waste recycling and energy efficiency through heat insulation. The foaming can be initiated by a chemical or physical process. Chemical foaming with aid of a foaming agent is the dominant industrial process. Physical foaming has two...... variations. One way is by saturation of glass melts with gas. The other involves sintering of powdered glass under a high gas pressure resulting in glass pellets with high pressure bubbles entrapped. Reheating the glass pellets above the glass transition temperature under ambient pressure allows the bubbles...

  20. Magnetic and Superconducting Materials at High Pressures

    Energy Technology Data Exchange (ETDEWEB)

    Struzhkin, Viktor V. [Carnegie Inst. of Washington, Washington, DC (United States)

    2015-03-24

    The work concentrates on few important tasks in enabling techniques for search of superconducting compressed hydrogen compounds and pure hydrogen, investigation of mechanisms of high-Tc superconductivity, and exploring new superconducting materials. Along that route we performed several challenging tasks, including discovery of new forms of polyhydrides of alkali metal Na at very high pressures. These experiments help us to establish the experimental environment that will provide important information on the high-pressure properties of hydrogen-rich compounds. Our recent progress in RIXS measurements opens a whole field of strongly correlated 3d materials. We have developed a systematic approach to measure major electronic parameters, like Hubbard energy U, and charge transfer energy Δ, as function of pressure. This technique will enable also RIXS studies of magnetic excitations in iridates and other 5d materials at the L edge, which attract a lot of interest recently. We have developed new magnetic sensing technique based on optically detected magnetic resonance from NV centers in diamond. The technique can be applied to study superconductivity in high-TC materials, to search for magnetic transitions in strongly correlated and itinerant magnetic materials under pressure. Summary of Project Activities; development of high-pressure experimentation platform for exploration of new potential superconductors, metal polyhydrides (including newly discovered alkali metal polyhydrides), and already known superconductors at the limit of static high-pressure techniques; investigation of special classes of superconducting compounds (high-Tc superconductors, new superconducting materials), that may provide new fundamental knowledge and may prove important for application as high-temperature/high-critical parameter superconductors; investigation of the pressure dependence of superconductivity and magnetic/phase transformations in 3d transition metal compounds, including