WorldWideScience

Sample records for high precision axial

  1. High-precision efficiency calibration of a high-purity co-axial germanium detector

    Energy Technology Data Exchange (ETDEWEB)

    Blank, B., E-mail: blank@cenbg.in2p3.fr [Centre d' Etudes Nucléaires de Bordeaux Gradignan, UMR 5797, CNRS/IN2P3, Université de Bordeaux, Chemin du Solarium, BP 120, 33175 Gradignan Cedex (France); Souin, J.; Ascher, P.; Audirac, L.; Canchel, G.; Gerbaux, M.; Grévy, S.; Giovinazzo, J.; Guérin, H.; Nieto, T. Kurtukian; Matea, I. [Centre d' Etudes Nucléaires de Bordeaux Gradignan, UMR 5797, CNRS/IN2P3, Université de Bordeaux, Chemin du Solarium, BP 120, 33175 Gradignan Cedex (France); Bouzomita, H.; Delahaye, P.; Grinyer, G.F.; Thomas, J.C. [Grand Accélérateur National d' Ions Lourds, CEA/DSM, CNRS/IN2P3, Bvd Henri Becquerel, BP 55027, F-14076 CAEN Cedex 5 (France)

    2015-03-11

    A high-purity co-axial germanium detector has been calibrated in efficiency to a precision of about 0.15% over a wide energy range. High-precision scans of the detector crystal and γ-ray source measurements have been compared to Monte-Carlo simulations to adjust the dimensions of a detector model. For this purpose, standard calibration sources and short-lived online sources have been used. The resulting efficiency calibration reaches the precision needed e.g. for branching ratio measurements of super-allowed β decays for tests of the weak-interaction standard model.

  2. High Precision Electon Beam Polarimetry

    National Research Council Canada - National Science Library

    Dutta, D

    2016-01-01

    Over the last three decades high precision electron beam polarimetry has been at the fore-front of progress made in leveraging the spin degrees of freedom in nuclear and particle physics experiments...

  3. High-Frequency Axial Fatigue Test Procedures for Spectrum Loading

    Science.gov (United States)

    2016-07-20

    REPORT NO: NAWCADPAX/TIM-2016/49 HIGH - FREQUENCY AXIAL FATIGUE TEST PROCEEDURES FOR SPECTRUM LOADING by David T. Rusk, AIR...OF THE NAVY NAVAL AIR WARFARE CENTER AIRCRAFT DIVISION PATUXENT RIVER, MARYLAND NAWCADPAX/TIM-2016/49 20 July 2016 HIGH - FREQUENCY AXIAL...Technical Information Memorandum 3. DATES COVERED 4. TITLE AND SUBTITLE High - Frequency Axial Fatigue Test Procedures for Spectrum Loading

  4. High Precision Measurements Using High Frequency Signals

    CERN Document Server

    Jin, Aohan; Sakurai, Atsunori; Liu, Liang; Edman, Fredrik; Öwall, Viktor; Pullerits, Tonu; Karki, Khadga J

    2014-01-01

    Generalized lock-in amplifiers use digital cavities with Q-factors as high as 5X10^8. In this letter, we show that generalized lock-in amplifiers can be used to analyze microwave (giga-hertz) signals with a precision of few tens of hertz. We propose that the physical changes in the medium of propagation can be measured precisely by the ultra-high precision measurement of the signal. We provide evidence to our proposition by verifying the Newton's law of cooling by measuring the effect of change in temperature on the phase and amplitude of the signals propagating through two calibrated cables. The technique could be used to precisely measure different physical properties of the propagation medium, for example length, resistance, etc. Real time implementation of the technique can open up new methodologies of in-situ virtual metrology in material design.

  5. Effect of Deformation Condition on Axial CompressivePrecision Forming Process of Tube with Curling Die

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The effect of the deformation condition on the axial compressive precision forming process of tube with curling die was investigated by using a rigid-plastic FEM. The results show that the forming accuracy depends mainly on geometric condition rρ/d0, little on tube material properties and friction condition; the relative gap Δ/2rρ of double-walled tubes obtained decreases with increasing rρ/d0, and there is a parameter k for a given t0/d0 or rρ/t0, when rρ,/d0>k, Δ/2rρ<1,otherwise Δ/2rρ>1.

  6. Recent Results on High-Pressure Axial Blowers

    Science.gov (United States)

    Eckert, B.

    1947-01-01

    Considerable progress has, in recent times, been attained in the development of the high-pressure axial blower by well-planned research. The efforts are directed toward improving the efficiencies, which are already high for the axial blower, and in particular the delivery pressure heads. For high pressures multistage arrangements are used. Of fundamental importance is the careful design of all structural parts of the blower that are subject to the effects of the flow. In the present report, several recent results and experiences are reported, which are based on results of German engine research.

  7. High Power Co-Axial Coupler

    Energy Technology Data Exchange (ETDEWEB)

    Neubauer, M. [Muons, Inc.; Dudas, A. [Muons, Inc.; Rimmer, Robert A. [JLAB; Guo, Jiquan [JLAB; Williams, R. Scott [JLAB

    2013-12-01

    A very high power Coax RF Coupler (MW-Level) is very desirable for a number of accelerator and commercial applications. For example, the development of such a coupler operating at 1.5 GHz may permit the construction of a higher-luminosity version of the Electron-Ion Collider (EIC) being planned at JLab. Muons, Inc. is currently funded by a DOE STTR grant to develop a 1.5-GHz high-power doublewindowcoax coupler with JLab (about 150 kW). Excellent progress has been made on this R&D project, so we propose an extension of this development to build a very high power coax coupler (MW level peak power and a max duty factor of about 4%). The dimensions of the current coax coupler will be scaled up to provide higher power capability.

  8. High precision thermal neutron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Radeka, V.; Schaknowski, N.A.; Smith, G.C.; Yu, B. [Brookhaven National Laboratory, Upton, NY (United States)

    1994-12-31

    Two-dimensional position sensitive detectors are indispensable in neutron diffraction experiments for determination of molecular and crystal structures in biology, solid-state physics and polymer chemistry. Some performance characteristics of these detectors are elementary and obvious, such as the position resolution, number of resolution elements, neutron detection efficiency, counting rate and sensitivity to gamma-ray background. High performance detectors are distinguished by more subtle characteristics such as the stability of the response (efficiency) versus position, stability of the recorded neutron positions, dynamic range, blooming or halo effects. While relatively few of them are needed around the world, these high performance devices are sophisticated and fairly complex, their development requires very specialized efforts. In this context, we describe here a program of detector development, based on {sup 3}He filled proportional chambers, which has been underway for some years at the Brookhaven National Laboratory. Fundamental approaches and practical considerations are outlined that have resulted in a series of high performance detectors with the best known position resolution, position stability, uniformity of response and reliability over time, for devices of this type.

  9. The axial topographic high at intermediate and fast spreading ridges

    Science.gov (United States)

    Carbotte, Suzanne M.; MacDonald, Ken C.

    1994-12-01

    An axial topographic high is commonly observed at both fast spreading ridges and some segments of intermediate spreading ridges. At fast rates the axial high is primarily created by the buoyancy of hot rock and magma beneath the rise. As newly formed crust is transported off axis, little vestige of an axial high is observed on the ridge flanks. In contrast, at intermediate rates, a significant component of the positive topography may be a volcanic construction, preserved on the ridge flanks as abyssal hills, which are slit axial volcanoes. We suggest this difference in the nature of the axial high reflects a lithosphere strong enough to support construction of a volcanic crestal ridge at intermediate spreading rates, but only rarely at fast rates. Relict overlap ridges, found within the discordant zones left by overlapping spreading centers, is one class of ridge-flank topography which appears to have a significant volcanic constructional component even at fast spreading ridges. Unlike topography away from these discontinuities, the relief and shape of overlapping spreading centers is preserved as relict ridge tips are rafted onto the ridge flanks. Reduced magma supply at these discontinuities may give rise to an axial lithosphere strong enough to support volcanic construction of overlap ridges. Low axial lithospheric strength may also account for the lack of normal faults within the innermost 1-2 km of fast, and some intermediate, spreading ridges. With a thin/weak brittle layer at the ridge crest, tensile failure will predominate and few normal faults will form. Depths to the axial magma chamber reflector observed in multi-channel seismic data limit the thickness of the brittel layer on axis to less than 1-2 km for much of the East Pacific Rise (EPR). This depth is comparable to depths over which tensile failure within the oceanic crust will predominate, estimated from the Griffith criteria for fracture initiation (approx. 0.5-1.5 km). As the brittle layer

  10. High-resolution axial MR imaging of tibial stress injuries

    Directory of Open Access Journals (Sweden)

    Mammoto Takeo

    2012-05-01

    Full Text Available Abstract Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries.

  11. Research News -- Meson scattering at high precision

    CERN Document Server

    Ananthanarayan, B

    2007-01-01

    A fascinating new generation of experiments has determined certain meson scattering parameters at high precision. A confluence of highly sophisticated theory as well as new experimental ideas have led to this state of affairs, which sheds important light on the properties of the strong interactions. A brief review of the experiments and the theory is presented.

  12. High-Precision Computation and Mathematical Physics

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, David H.; Borwein, Jonathan M.

    2008-11-03

    At the present time, IEEE 64-bit floating-point arithmetic is sufficiently accurate for most scientific applications. However, for a rapidly growing body of important scientific computing applications, a higher level of numeric precision is required. Such calculations are facilitated by high-precision software packages that include high-level language translation modules to minimize the conversion effort. This paper presents a survey of recent applications of these techniques and provides some analysis of their numerical requirements. These applications include supernova simulations, climate modeling, planetary orbit calculations, Coulomb n-body atomic systems, scattering amplitudes of quarks, gluons and bosons, nonlinear oscillator theory, Ising theory, quantum field theory and experimental mathematics. We conclude that high-precision arithmetic facilities are now an indispensable component of a modern large-scale scientific computing environment.

  13. Resimulation of noise: a precision estimator for least square error curve-fitting tested for axial strain time constant imaging.

    Science.gov (United States)

    Nair, S P; Righetti, R

    2015-05-07

    Recent elastography techniques focus on imaging information on properties of materials which can be modeled as viscoelastic or poroelastic. These techniques often require the fitting of temporal strain data, acquired from either a creep or stress-relaxation experiment to a mathematical model using least square error (LSE) parameter estimation. It is known that the strain versus time relationships for tissues undergoing creep compression have a non-linear relationship. In non-linear cases, devising a measure of estimate reliability can be challenging. In this article, we have developed and tested a method to provide non linear LSE parameter estimate reliability: which we called Resimulation of Noise (RoN). RoN provides a measure of reliability by estimating the spread of parameter estimates from a single experiment realization. We have tested RoN specifically for the case of axial strain time constant parameter estimation in poroelastic media. Our tests show that the RoN estimated precision has a linear relationship to the actual precision of the LSE estimator. We have also compared results from the RoN derived measure of reliability against a commonly used reliability measure: the correlation coefficient (CorrCoeff). Our results show that CorrCoeff is a poor measure of estimate reliability for non-linear LSE parameter estimation. While the RoN is specifically tested only for axial strain time constant imaging, a general algorithm is provided for use in all LSE parameter estimation.

  14. High-speed precision motion control

    CERN Document Server

    Yamaguchi, Takashi; Pang, Chee Khiang

    2011-01-01

    Written for researchers and postgraduate students in Control Engineering, as well as professionals in the Hard Disk Drive industry, this book discusses high-precision and fast servo controls in Hard Disk Drives (HDDs). The editors present a number of control algorithms that enable fast seeking and high precision positioning, and propose problems from commercial products, making the book valuable to researchers in HDDs. Each chapter is self contained, and progresses from concept to technique, present application examples that can be used within automotive, aerospace, aeronautical, and manufactu

  15. Surface texture metrology for high precision surfaces

    DEFF Research Database (Denmark)

    Hansen, Hans Nørgaard; Gasparin, Stefania; Tosello, Guido

    2010-01-01

    This paper introduces some of the challenges related to surface texture measurement of high precision surfaces. The paper is presenting two case studies related to polished tool surfaces and micro part surfaces. In both cases measuring instrumentation, measurement procedure and the measurement...

  16. High precision, rapid laser hole drilling

    Science.gov (United States)

    Chang, Jim J.; Friedman, Herbert W.; Comaskey, Brian J.

    2013-04-02

    A laser system produces a first laser beam for rapidly removing the bulk of material in an area to form a ragged hole. The laser system produces a second laser beam for accurately cleaning up the ragged hole so that the final hole has dimensions of high precision.

  17. Surface texture metrology for high precision surfaces

    DEFF Research Database (Denmark)

    Hansen, Hans Nørgaard; Gasparin, Stefania; Tosello, Guido

    2010-01-01

    This paper introduces some of the challenges related to surface texture measurement of high precision surfaces. The paper is presenting two case studies related to polished tool surfaces and micro part surfaces. In both cases measuring instrumentation, measurement procedure and the measurement re...

  18. High-Precision Photometry with the RCT

    Science.gov (United States)

    Everett, M.; Howell, S.; Davis, D.; McGruder, C. H., III; Gelderman, R.; Guinan, E.; Mattox, J. R.; Walter, D. K.

    2003-05-01

    We plan to conduct a high-precision photometric search for transitting extra-solar planets using the refurbished 1.3 m (50 inch) Robotically-Controlled Telescope (RCT) at Kitt Peak. The photometric capabilities and extra-solar planet search strategy for the RCT are discussed. Refurbishment of the RCT has been made possible by NASA grant NAG58762.

  19. High precision radial velocities with GIANO spectra

    CERN Document Server

    Carleo, I; Gratton, R; Benatti, S; Bonavita, M; Oliva, E; Origlia, L; Desidera, S; Claudi, R; Sissa, E

    2016-01-01

    Radial velocities (RV) measured from near-infrared (NIR) spectra are a potentially excellent tool to search for extrasolar planets around cool or active stars. High resolution infrared (IR) spectrographs now available are reaching the high precision of visible instruments, with a constant improvement over time. GIANO is an infrared echelle spectrograph at the Telescopio Nazionale Galileo (TNG) and it is a powerful tool to provide high resolution spectra for accurate RV measurements of exoplanets and for chemical and dynamical studies of stellar or extragalactic objects. No other high spectral resolution IR instrument has GIANO's capability to cover the entire NIR wavelength range (0.95-2.45 micron) in a single exposure. In this paper we describe the ensemble of procedures that we have developed to measure high precision RVs on GIANO spectra acquired during the Science Verification (SV) run, using the telluric lines as wavelength reference. We used the Cross Correlation Function (CCF) method to determine the v...

  20. High precision detector robot arm system

    Science.gov (United States)

    Shu, Deming; Chu, Yong

    2017-01-31

    A method and high precision robot arm system are provided, for example, for X-ray nanodiffraction with an X-ray nanoprobe. The robot arm system includes duo-vertical-stages and a kinematic linkage system. A two-dimensional (2D) vertical plane ultra-precision robot arm supporting an X-ray detector provides positioning and manipulating of the X-ray detector. A vertical support for the 2D vertical plane robot arm includes spaced apart rails respectively engaging a first bearing structure and a second bearing structure carried by the 2D vertical plane robot arm.

  1. High precision detector robot arm system

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Deming; Chu, Yong

    2017-01-31

    A method and high precision robot arm system are provided, for example, for X-ray nanodiffraction with an X-ray nanoprobe. The robot arm system includes duo-vertical-stages and a kinematic linkage system. A two-dimensional (2D) vertical plane ultra-precision robot arm supporting an X-ray detector provides positioning and manipulating of the X-ray detector. A vertical support for the 2D vertical plane robot arm includes spaced apart rails respectively engaging a first bearing structure and a second bearing structure carried by the 2D vertical plane robot arm.

  2. Portable high precision pressure transducer system

    Science.gov (United States)

    Piper, T. C.; Morgan, J. P.; Marchant, N. J.; Bolton, S. M.

    A high precision pressure transducer system for checking the reliability of a second pressure transducer system used to monitor the level of a fluid confined in a holding tank is presented. Since the response of the pressure transducer is temperature sensitive, it is continually housed in a battery powered oven which is configured to provide a temperature stable environment at specified temperature for an extended period of time. Further, a high precision temperature stabilized oscillator and counter are coupled to a single board computer to accurately determine the pressure transducer oscillation frequency and convert it to an applied pressure. All of the components are powered by the batteries which during periods of availability of line power are charged by an on-board battery charger. The pressure readings outputs are transmitted to a line printer and a vacuum fluorescent display.

  3. Note: High precision measurements using high frequency gigahertz signals

    Science.gov (United States)

    Jin, Aohan; Fu, Siyuan; Sakurai, Atsunori; Liu, Liang; Edman, Fredrik; Pullerits, Tõnu; Öwall, Viktor; Karki, Khadga Jung

    2014-12-01

    Generalized lock-in amplifiers use digital cavities with Q-factors as high as 5 × 108 to measure signals with very high precision. In this Note, we show that generalized lock-in amplifiers can be used to analyze microwave (giga-hertz) signals with a precision of few tens of hertz. We propose that the physical changes in the medium of propagation can be measured precisely by the ultra-high precision measurement of the signal. We provide evidence to our proposition by verifying the Newton's law of cooling by measuring the effect of change in temperature on the phase and amplitude of the signals propagating through two calibrated cables. The technique could be used to precisely measure different physical properties of the propagation medium, for example, the change in length, resistance, etc. Real time implementation of the technique can open up new methodologies of in situ virtual metrology in material design.

  4. Precision mass measurements of highly charged ions

    Science.gov (United States)

    Kwiatkowski, A. A.; Bale, J. C.; Brunner, T.; Chaudhuri, A.; Chowdhury, U.; Ettenauer, S.; Frekers, D.; Gallant, A. T.; Grossheim, A.; Lennarz, A.; Mane, E.; MacDonald, T. D.; Schultz, B. E.; Simon, M. C.; Simon, V. V.; Dilling, J.

    2012-10-01

    The reputation of Penning trap mass spectrometry for accuracy and precision was established with singly charged ions (SCI); however, the achievable precision and resolving power can be extended by using highly charged ions (HCI). The TITAN facility has demonstrated these enhancements for long-lived (T1/2>=50 ms) isobars and low-lying isomers, including ^71Ge^21+, ^74Rb^8+, ^78Rb^8+, and ^98Rb^15+. The Q-value of ^71Ge enters into the neutrino cross section, and the use of HCI reduced the resolving power required to distinguish the isobars from 3 x 10^5 to 20. The precision achieved in the measurement of ^74Rb^8+, a superallowed β-emitter and candidate to test the CVC hypothesis, rivaled earlier measurements with SCI in a fraction of the time. The 111.19(22) keV isomeric state in ^78Rb was resolved from the ground state. Mass measurements of neutron-rich Rb and Sr isotopes near A = 100 aid in determining the r-process pathway. Advanced ion manipulation techniques and recent results will be presented.

  5. Recent high precision surveys at PEP

    Energy Technology Data Exchange (ETDEWEB)

    Sah, R.C.

    1980-12-01

    The task of surveying and aligning the components of PEP has provided an opportunity to develop new instruments and techniques for the purpose of high precision surveys. The new instruments are quick and easy to use, and they automatically encode survey data and read them into the memory of an on-line computer. When measurements of several beam elements have been taken, the on-line computer analyzes the measured data, compares them with desired parameters, and calculates the required adjustments to beam element support stands.

  6. Precision timing measurements for high energy photons

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Dustin, E-mail: djanders@caltech.edu [California Institute of Technology, 1200 E California Blvd, Pasadena, CA 91125 (United States); Apreysan, Artur; Bornheim, Adi; Duarte, Javier; Newman, Harvey; Pena, Cristian [California Institute of Technology, 1200 E California Blvd, Pasadena, CA 91125 (United States); Ronzhin, Anatoly [Fermi National Accelerator Laboratory, P.O. Box 500, Batavia, IL 60510 (United States); Spiropulu, Maria; Trevor, Jason; Xie, Si; Zhu, Ren-Yuan [California Institute of Technology, 1200 E California Blvd, Pasadena, CA 91125 (United States)

    2015-07-01

    Particle colliders operating at high luminosities present challenging environments for high energy physics event reconstruction and analysis. We discuss how timing information, with a precision on the order of 10 ps, can aid in the reconstruction of physics events under such conditions. We present calorimeter based timing measurements from test beam experiments in which we explore the ultimate timing precision achievable for high energy photons or electrons of 10 GeV and above. Using a prototype calorimeter consisting of a 1.7×1.7×1.7 cm{sup 3} lutetium–yttrium oxyortho-silicate (LYSO) crystal cube, read out by micro-channel plate photomultipliers, we demonstrate a time resolution of 33.5±2.1 ps for an incoming beam energy of 32 GeV. In a second measurement, using a 2.5×2.5×20 cm{sup 3} LYSO crystal placed perpendicularly to the electron beam, we achieve a time resolution of 59±11 ps using a beam energy of 4 GeV. We also present timing measurements made using a shashlik-style calorimeter cell made of LYSO and tungsten plates, and demonstrate that the apparatus achieves a time resolution of 54±5 ps for an incoming beam energy of 32 GeV.

  7. Precision timing measurements for high energy photons

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Dustin [California Inst. of Technology (CalTech), Pasadena, CA (United States); Apreysan, Artur [California Inst. of Technology (CalTech), Pasadena, CA (United States); Bornheim, Adi [California Inst. of Technology (CalTech), Pasadena, CA (United States); Duarte, Javier [California Inst. of Technology (CalTech), Pasadena, CA (United States); Newman, Harvey [California Inst. of Technology (CalTech), Pasadena, CA (United States); Pena, Cristian [California Inst. of Technology (CalTech), Pasadena, CA (United States); Ronzhin, Anatoly [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Spiropulu, Maria [California Inst. of Technology (CalTech), Pasadena, CA (United States); Trevor, Jason [California Inst. of Technology (CalTech), Pasadena, CA (United States); Xie, Si [California Inst. of Technology (CalTech), Pasadena, CA (United States); Zhu, Ren-Yuan [California Inst. of Technology (CalTech), Pasadena, CA (United States)

    2014-11-21

    Particle colliders operating at high luminosities present challenging environments for high energy physics event reconstruction and analysis. We discuss how timing information, with a precision on the order of 10 ps, can aid in the reconstruction of physics events under such conditions. We present calorimeter based timing measurements from test beam experiments in which we explore the ultimate timing precision achievable for high energy photons or electrons of 10 GeV and above. Using a prototype calorimeter consisting of a 1.7×1.7×1.7 cm3 lutetium–yttrium oxyortho-silicate (LYSO) crystal cube, read out by micro-channel plate photomultipliers, we demonstrate a time resolution of 33.5±2.1 ps for an incoming beam energy of 32 GeV. In a second measurement, using a 2.5×2.5×20 cm3 LYSO crystal placed perpendicularly to the electron beam, we achieve a time resolution of 59±11 ps using a beam energy of 4 GeV. We also present timing measurements made using a shashlik-style calorimeter cell made of LYSO and tungsten plates, and demonstrate that the apparatus achieves a time resolution of 54±5 ps for an incoming beam energy of 32 GeV.

  8. High precision optomechanical assembly using threads as mechanical reference

    Science.gov (United States)

    Lamontagne, Frédéric; Desnoyers, Nichola; Bergeron, Guy; Cantin, Mario

    2016-09-01

    A convenient method to assemble optomechanical components is to use threaded interface. For example, lenses are often secured inside barrels using threaded rings. In other cases, multiple optical sub-assemblies such as lens barrels can be threaded to each other. Threads have the advantage to provide a simple assembly method, to be easy to manufacture, and to offer a compact mechanical design. On the other hand, threads are not considered to provide accurate centering between parts because of the assembly clearance between the inner and outer threads. For that reason, threads are often used in conjunction with precision cylindrical surfaces to limit the radial clearance between the parts to be centered. Therefore, tight manufacturing tolerances are needed on these pilot diameters, which affect the cost of the optical assembly. This paper presents a new optomechanical approach that uses threads as mechanical reference. This innovative method relies on geometric principles to auto-center parts to each other with a very low centering error that is usually less than 5 μm. The method allows to auto-center an optical group in a main barrel, to perform an axial adjustment of an optical group inside a main barrel, and to perform stacking of multiple barrels. In conjunction with the lens auto-centering method that also used threads as a mechanical reference, this novel solution opens new possibilities to realize a variety of different high precision optomechanical assemblies at lower cost.

  9. The Kenya rift axial gravity high: a re-interpretation

    Science.gov (United States)

    Swain, C. J.

    1992-03-01

    Since KRISP 85 did not provide overwhelming evidence for the massive intrusion that was originally suggested to explain the axial gravity high yet did provide a velocity section for the upper crust along the axis of the Kenya Rift, it is appropriate to use this section to control a re-interpretation of the gravity anomalies. A 2 {1}/{2} D inversion procedure has been used to model a number of isostatic anomaly profiles between Lake Baringo and Suswa. There are too many unknowns and gravity station coverage is too sparse for the results to be unique. Nevertheless, certain conclusions can be drawn. One of those is that some relatively dense material exists within the basement all along the Rift axis, since the axial isostatic anomalies are positive even though they occur where there are several thousand metres of Cenozoic volcanics of relatively low density (inferred from their seismic velocity of 3.7-5.1 km/s). The dense material is envisaged as a zone of dyke injection and assigned a density of 2.75-2.76 g/cm 3 (corresponding to its 6.05 km/s velocity) compared to a normal basement density of 2.70 g/cm 3. It is assumed to extend down to 22 km—the top of the 7.1 km/s layer. The KRISP 85 line passed just east of Menengai, where the basement velocity increases to about 6.6 km/s over a distance of about 20 km. On an east-west gravity profile through Menengai there is a gravity high corresponding to this velocity increase which has been modelled as a basic intrusion (density 2.93 g/cm 3) underlying the caldera.

  10. Mechanical Analysis of high precision manipulator

    Directory of Open Access Journals (Sweden)

    O.J. Elle

    1995-10-01

    Full Text Available It is of great importance that high precision manipulators are well designed from a mechanical point of view. A thorough analysis of all mechanical aspects concerning an accurate manipulator will make a good basis for further design. This paper presents a new approach to mechanical analysis of high-precision manipulators. A typical six axis anthropomorphic manipulator configuration is chosen as a model for the analysis. The paper is divided into two main parts; static deformation analysis and dynamic analysis. The static deformation analysis consists of three sub-parts; link deformation, joint deformation and total mechanical deformation. A simple fixed beam deformation model is used to simulate every link. Both specific gravity and a load attached at the end of the beam is considered. By varying material, outer dimensions and wall thickness it is possible to determine optimal values. Looking at the whole structure with an attacking force at the end, it is possible to select appropriate motor/transmission combinations. Each combination represents compliance and combined with the arm compliance the total deformation can be found. The result shows that deformation due to compliance in the joints represents 97

  11. Stall inception in a high-speed axial compressor

    Science.gov (United States)

    Cameron, Joshua David

    A research program designed to provide understanding of the fluid dynamic mechanisms that lead to rotating stall in the Notre Dame Stage 01 high-speed axial compressor is described. The stalling behavior of this compressor was studied with unsteady casing pressure measurements from a circumferentially spaced array of sensors. In addition, over rotor casing surface streak measurements were performed to investigate the time-averaged end-wall flow near the rotor at operating points near stall. Several investigative tools were applied to the analysis and interpretation of the unsteady casing pressure data. Traditional methods such as visual inspection, spatial Fourier decomposition, traveling wave energy and wavelet analysis were shown to be insufficient to characterize the pre-stall and stall inception behavior of the compressor. A new technique based on a windowed two-point correlation between adjacent sensors was developed and demonstrated to provide spatial and temporal resolution of both pre-stall and stall inception behavior. The spatial correlation technique was then applied to the analysis of stall inception data from experiments with asymmetric tip clearance. The non-uniform tip clearance was produced using the magnetic bearings which levitate the rotor shaft of the Notre Dame Transonic Axial Compressor facility. Both steady rotor centerline offset and rotor whirl were investigated. The results of these experiments, along with the surface streak measurements, provide evidence in support of recent computational observations (found in the literature) that predict that short length scale stall inception is related to specific features of the rotor tip clearance flow.

  12. Digitalization of highly precise fluxgate magnetometers

    DEFF Research Database (Denmark)

    Cerman, Ales; Kuna, A.; Ripka, P.

    2005-01-01

    This paper describes the theory behind all three known ways of digitalizing the fluxgate magnetometers: analogue magnetometers with digitalized output using high resolution ADC, application of the delta-sigma modulation to the sensor feedback loop and fully digital signal detection. At present time...... the Delta-Sigma ADCs are mostly used for the digitalization of the highly precise fluxgate magnetorneters. The relevant part of the paper demonstrates some pitfalls of their application studied during the design of the magnetometer for the new Czech scientific satellite MIMOSA. The part discussing...... the application of the A-E modulation to the sensor feedback loop theoretically derives the main advantage of this method-increasing of the modulation order and shows its real potential compared to the analog magnetometer with consequential digitalization. The comparison is realized on the modular magnetometer...

  13. Digitalization of highly precise fluxgate magnetometers

    DEFF Research Database (Denmark)

    Cerman, Ales; Kuna, A.; Ripka, P.

    2005-01-01

    allowing configurations with modulator inside and outside the feedback loop. The last principle is demonstrated on the project of the fully digital fluxgate magnetometer based on the digital signal processor (DSP). The results of the presented projects are compared with recently published competitive......This paper describes the theory behind all three known ways of digitalizing the fluxgate magnetometers: analogue magnetometers with digitalized output using high resolution ADC, application of the delta-sigma modulation to the sensor feedback loop and fully digital signal detection. At present time...... the Delta-Sigma ADCs are mostly used for the digitalization of the highly precise fluxgate magnetorneters. The relevant part of the paper demonstrates some pitfalls of their application studied during the design of the magnetometer for the new Czech scientific satellite MIMOSA. The part discussing...

  14. High precision innovative micropump for artificial pancreas

    Science.gov (United States)

    Chappel, E.; Mefti, S.; Lettieri, G.-L.; Proennecke, S.; Conan, C.

    2014-03-01

    The concept of artificial pancreas, which comprises an insulin pump, a continuous glucose meter and a control algorithm, is a major step forward in managing patient with type 1 diabetes mellitus. The stability of the control algorithm is based on short-term precision micropump to deliver rapid-acting insulin and to specific integrated sensors able to monitor any failure leading to a loss of accuracy. Debiotech's MEMS micropump, based on the membrane pump principle, is made of a stack of 3 silicon wafers. The pumping chamber comprises a pillar check-valve at the inlet, a pumping membrane which is actuated against stop limiters by a piezo cantilever, an anti-free-flow outlet valve and a pressure sensor. The micropump inlet is tightly connected to the insulin reservoir while the outlet is in direct communication with the patient skin via a cannula. To meet the requirement of a pump dedicated to closed-loop application for diabetes care, in addition to the well-controlled displacement of the pumping membrane, the high precision of the micropump is based on specific actuation profiles that balance effect of pump elasticity in low-consumption push-pull mode.

  15. Bidirectional axial transmission can improve accuracy and precision of ultrasonic velocity measurement in cortical bone: a validation on test materials.

    Science.gov (United States)

    Bossy, Emmanuel; Talmant, Maryline; Defontaine, Marielle; Patat, Frédéric; Laugier, Pascal

    2004-01-01

    The axial transmission technique uses a linear arrangement of ultrasonic emitters and receivers placed on a same side of a cortical bone site in contact with the skin, involving ultrasonic propagation along the axis of bone. The velocity of the waves radiated from bone has been shown to reflect bone status. The thickness and composition of soft tissue may vary along the length of the bone, between different skeletal sites, or between subjects. Hence, accurate estimates of velocity require first to eliminate the effect of the overlying soft tissue that is traversed by the ultrasound wave. To correct for such bias without measuring soft tissue properties, we designed new ultrasonic probes in the 1-2 MHz frequency range. It is based on propagation along the bone surface in two opposite directions from two sources placed on both sides of a unique group of receivers. The aim is to obtain an unbiased estimate of the velocity without any intermediate calculation of soft tissue properties, such as thickness variation or velocity. Validation tests were performed on academic material such as Perspex or aluminum. We found that head wave velocity values could be biased by more than 10% for inclination of a few degrees between the test specimen surface and the probe. On test materials, the compensation procedure implemented in our probe led to a relative precision error on velocity measurement lower than 0.2 to 0.3%. These results suggest that the correction procedure allows measuring in vivo velocities independently of soft tissue properties.

  16. Influence of patient axial malpositioning on the trueness and precision of pelvic parameters obtained from 3D reconstructions based on biplanar radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Ghostine, Bachir; Assi, Ayman [Institut de Biomecanique Humaine Georges Charpak, Arts et Metiers ParisTech, Paris (France); University of Saint-Joseph, Laboratory of Biomechanics and Medical Imaging, Faculty of Medicine, Beirut (Lebanon); Sauret, Christophe; Skalli, Wafa [Institut de Biomecanique Humaine Georges Charpak, Arts et Metiers ParisTech, Paris (France); Bakouny, Ziad; Khalil, Nour [University of Saint-Joseph, Laboratory of Biomechanics and Medical Imaging, Faculty of Medicine, Beirut (Lebanon); Ghanem, Ismat [University of Saint-Joseph, Laboratory of Biomechanics and Medical Imaging, Faculty of Medicine, Beirut (Lebanon); University of Saint-Joseph, Hotel-Dieu de France Hospital, Beirut (Lebanon)

    2017-03-15

    Radiographs are often performed to assess pelvic and hip parameters, but results depend upon correct pelvis positioning. Three-dimensional (3D) reconstruction from biplanar-radiographs should provide parameters that are less sensitive to pelvic orientation, but this remained to be evaluated. Computerized-tomographic scans of six patients were used both as a reference and for generating simulated frontal and lateral radiographs. These simulated radiographs were generated while introducing axial rotations of the pelvis ranging from 0 to 20 . Simulated biplanar-radiographs were utilized by four operators, three times each, to perform pelvic 3D-reconstructions. These reconstructions were used to assess the trueness, precision and global uncertainty of radiological pelvic and hip parameters for each position. In the neutral position, global uncertainty ranged between ± 2 for pelvic tilt and ± 9 for acetabular posterior sector angle and was mainly related to precision errors (ranging from 1.5 to 7 ). With increasing axial rotation, global uncertainty increased and ranged between ± 5 for pelvic tilt and ± 11 for pelvic incidence, sacral slope and acetabular anterior sector angle, mainly due to precision errors. Radiological parameters obtained from 3D-reconstructions, based on biplanar-radiographs, are less sensitive to axial rotation compared to plain radiographs. However, the axial rotation should nonetheless not exceed 10 . (orig.)

  17. High precision laser forming for micro actuation

    NARCIS (Netherlands)

    Folkersma, Ger K.G.P.; Römer, G.R.B.E.; Brouwer, D.M.; Huis in 't Veld, A.J.; Nakata, Yoshiki; Xu, Xianfan; Roth, Stephan; Neuenschwander, Beat

    2014-01-01

    For assembly of micro-devices, such as photonic devices, the precision alignment of components is often critical for their performance. Laser forming, also known as laser-adjusting, can be used to create an integrated microactuator to align the components with sub-micron precision after bonding. In

  18. High temperature superconducting axial field magnetic coupler: realization and test

    Science.gov (United States)

    Belguerras, L.; Mezani, S.; Lubin, T.; Lévêque, J.; Rezzoug, A.

    2015-09-01

    Contactless torque transmission through a large airgap is required in some industrial applications in which hermetic isolation is necessary. This torque transmission usually uses magnetic couplers, whose dimension strongly depends on the airgap flux density. The use of high temperature superconducting (HTS) coils to create a strong magnetic field may constitute a solution to reduce the size of the coupler. It is also possible to use this coupler to replace a torque tube in transmitting the torque produced by a HTS motor to its load. This paper presents the detailed construction and tests of an axial field HTS magnetic coupler. Pancake coils have been manufactured from BSCCO tape and used in one rotor of the coupler. The second rotor is mainly composed of NdFeB permanent magnets. Several tests have been carried out showing that the constructed coupler is working properly. A 3D finite element (FE) model of the studied coupler has been developed. Airgap magnetic field and torque measurements have been carried out and compared to the FE results. It has been shown that the measured and the computed quantities are in satisfactory agreement.

  19. Precision mechatronics based on high-precision measuring and positioning systems and machines

    Science.gov (United States)

    Jäger, Gerd; Manske, Eberhard; Hausotte, Tino; Mastylo, Rostyslav; Dorozhovets, Natalja; Hofmann, Norbert

    2007-06-01

    Precision mechatronics is defined in the paper as the science and engineering of a new generation of high precision systems and machines. Nanomeasuring and nanopositioning engineering represents important fields of precision mechatronics. The nanometrology is described as the today's limit of the precision engineering. The problem, how to design nanopositioning machines with uncertainties as small as possible will be discussed. The integration of several optical and tactile nanoprobes makes the 3D-nanopositioning machine suitable for various tasks, such as long range scanning probe microscopy, mask and wafer inspection, nanotribology, nanoindentation, free form surface measurement as well as measurement of microoptics, precision molds, microgears, ring gauges and small holes.

  20. Precision ring rolling technique and application in high-performance bearing manufacturing

    Directory of Open Access Journals (Sweden)

    Hua Lin

    2015-01-01

    Full Text Available High-performance bearing has significant application in many important industry fields, like automobile, precision machine tool, wind power, etc. Precision ring rolling is an advanced rotary forming technique to manufacture high-performance seamless bearing ring thus can improve the working life of bearing. In this paper, three kinds of precision ring rolling techniques adapt to different dimensional ranges of bearings are introduced, which are cold ring rolling for small-scale bearing, hot radial ring rolling for medium-scale bearing and hot radial-axial ring rolling for large-scale bearing. The forming principles, technological features and forming equipments for three kinds of precision ring rolling techniques are summarized, the technological development and industrial application in China are introduced, and the main technological development trend is described.

  1. High-precision astrometry towards ELTs

    CERN Document Server

    Massari, Davide; Tolstoy, Eline; McConnachie, Alan; Stuik, Remko; Schreiber, Laura; Andersen, David; Clénet, Yann; Davies, Richard; Gratadour, Damien; Kuijken, Konrad; Navarro, Ramon; Pott, Jörg-Uwe; Rodeghiero, Gabriele; Turri, Paolo; Kleijn, Gijs Verdoes

    2016-01-01

    With the aim of paving the road for future accurate astrometry with MICADO at the European-ELT, we performed an astrometric study using two different but complementary approaches to investigate two critical components that contribute to the total astrometric accuracy. First, we tested the predicted improvement in the astrometric measurements with the use of an atmospheric dispersion corrector (ADC) by simulating realistic images of a crowded Galactic globular cluster. We found that the positional measurement accuracy should be improved by up to ~2 mas with the ADC, making this component fundamental for high-precision astrometry. Second, we analysed observations of a globular cluster taken with the only currently available Multi-Conjugate Adaptive Optics assisted camera, GeMS/GSAOI at Gemini South. Making use of previously measured proper motions of stars in the field of view, we were able to model the distortions affecting the stellar positions. We found that they can be as large as ~200 mas, and that our bes...

  2. High-precision positioning of radar scatterers

    NARCIS (Netherlands)

    Dheenathayalan, P.; Small, D.; Schubert, A.; Hanssen, R.F.

    2016-01-01

    Remote sensing radar satellites cover wide areas and provide spatially dense measurements, with millions of scatterers. Knowledge of the precise position of each radar scatterer is essential to identify the corresponding object and interpret the estimated deformation. The absolute position accuracy

  3. High precision flux measurements with ENUBET

    Science.gov (United States)

    Pozzato, M.; ENUBET collaboration

    2017-09-01

    The challenges of precision neutrino physics (i.e the study of CP violation) require measurements of absolute ν cross sections at the GeV scale with exquisite (O(1)%) precision. Such precision is presently limited to about 10% by the uncertainties on neutrino flux at the source. A reduction of this uncertainty by one order of magnitude can be achieved monitoring the positron production in the decay tunnel originating from the Ke3 decays of charged kaons in a sign and momentum selected narrow band beam. This novel technique enables the measurement of the most relevant cross-sections for CP violation (νe and {\\displaystyle \\bar{ν }}e) with a precision of 1% and requires a special instrumented beam-line. Such non-conventional beam-line will be developed in the framework of the ENUBET Horizon-2020 Consolidator Grant (PI A. Longhin), recently approved by the European Research Council (grant agreement N° 681647). In this poster, we will present the Project and the early experimental results on ultra-compact calorimeters that can embedded in the instrumented decay tunnel.

  4. Design of High Precision Temperature Measurement System based on Labview

    Directory of Open Access Journals (Sweden)

    Weimin Zhu

    2015-06-01

    Full Text Available Using the LabVIEW software platform, a high precision temperature measuring device is designed based on the principle of the thermocouple. The system uses the STM32 MCU as the main control chip, using AD7076 analog digital converter. The converter has 8 channel, synchronous sampling, and bipolar input. Improving the precision of temperature measurement by cold end compensation, fitting and other measures. The test results show that, the device temperature measurement precision can reach ±0.1 °C, has the advantages of small size, high precision, and reliable performance, this high precision temperature measurement can be widely used in industrial production.

  5. High pressure axial flow fans for modern coal power stations

    Energy Technology Data Exchange (ETDEWEB)

    Cyrus, Vaclav [AHT Energetika s.r.o., Praha (Czech Republic); Koci, Petr [ZVVZ Milevsko a.s. (Czech Republic)

    2008-07-01

    Brown coal fired power stations, located in Northern Bohemia, have mostly older boiler blocks with an output of 110 and 200 MWe. Flue gases are cleaned by the desulphurization plants installed between 1993 and 1997. Usually, each boiler block has two air fans and one to three flue gas fans. Flue gas fans operate in severe conditions; fan blades should be resistant to the flue gases containing sulphur and acid drops with the operating temperature at 170 C to 190 C. Additionally, flue gas also often contains ash particles. Currently, some boiler blocks are gradually being refurbished. New blocks with an electrical power output of 600 to 700 MWe are at the design stage. Submitted paper shows our design study of one stage axial flow fan for the new blocks. Results from the new aerodynamic research of the axial flow stages were used in the fan design. (orig.)

  6. High Precision Orbit Determination of CHAMP Satellite

    Institute of Scientific and Technical Information of China (English)

    ZHAO Qile; LIU Jingnan; GE Maorong

    2006-01-01

    The precision orbit determination of challenging minisatellite payload(CHAMP) satellite was done based on position and navigation data analyst(PANDA) software which is developed in Wuhan University, using the onboard GPS data of year 2002 from day 126 to 131. The orbit accuracy was assessed by analyzing the difference from GFZ post-processed science orbits (PSO), the GPS carrier and pseudo-range data residuals and the satellite laser ranging (SLR) residuals.

  7. Prospects for High-Precision Pulsar Timing

    CERN Document Server

    Liu, K; Kramer, M; Stappers, B W; van Straten, W; Cordes, J M

    2011-01-01

    Timing pulses of pulsars has proved to be a most powerful technique useful to a host of research areas in astronomy and physics. Importantly, the precision of this timing is not only affected by radiometer noise, but also by intrinsic pulse shape changes, interstellar medium (ISM) evolution, instrumental distortions, etc. In this paper we review the known causes of pulse shape variations and assess their effect on the precision and accuracy of a single measurement of pulse arrival time with current instrumentation. Throughout this analysis we use the brightest and most precisely timed millisecond pulsar (MSP), PSR J0437-4715, as a case study, and develop a set of diagnostic tools to evaluate profile stability in timing observations. We conclude that most causes of distortion can be either corrected by state-of-the-art techniques or taken into account in the estimation of time-of-arrival (TOA) uncertainties. The advent of a new generation of radio telescopes (e.g. the Square Kilometre Array, SKA), and their in...

  8. High-precision spectroscopy of antiprotonic helium

    CERN Document Server

    Widmann, E

    2001-01-01

    We present first results of laser and microwave spectroscopy experiments of antiprotonic helium performed at the new Antiproton Decelerator (AD) at CERN. Extending a series of previous measurements done at the Low Energy Antiproton Ring (LEAR) of CERN, several laser- induced transitions of the antiproton in the exotic three-body system He/sup 2+/-e/sup -/-p could be determined with a precision down to 1.3*10/sup -7/. This constitutes an improvement of a factor 3 over previous measurements, and allows to test accurate three-body calculations of this system that include QED corrections. The observed agreement on the same level can be used to infer CPT limits on the antiproton charge and mass. Furthermore, a first indication of a resonance signal of a two-laser microwave triple experiment to measure the hyperfine splitting of antiprotonic helium could been observed. Such a measurement has the potential to determine the antiproton magnetic moment to a higher precision that it is known today. (19 refs).

  9. High-precision Absolute Coordinate Measurement using Frequency Scanned Interferometry

    CERN Document Server

    Chen, Tianxiang; Riles, Keith; Li, Cheng

    2013-01-01

    In this paper, we report high-precision absolute position measurement performed with frequency scanned interferometry (FSI). We reported previously on measurement of absolute distance with FSI [1]. Absolute position is determined by several related absolute distances measured simultaneously. The achieved precision of 2-dimensional measurements is better than 1 micron, and in 3-dimensional measurements, the precision on X and Y is confirmed to be below 1 micron, while the confirmed precision on Z is about 2 microns, where the confirmation is limited by the lower precision of the moving stage in Z direction.

  10. A Novel High-Precision Laser Wavemeter

    Institute of Scientific and Technical Information of China (English)

    WANG Li-qiang; ZHENG Hon-gxing

    2007-01-01

    The wavemeter can measure a wavelength of a tuned laser and an unknown laser. Due to the Doppler shift, the wavemeter operates and establishes coherent interference fringes on the detectors according to the Michelson interference principle. The electronic signals of the reference laser and an unknown laser both are multiplied frequency by PLL (Phase-Locked Loop) unit so as to enhance the resolutions of the wavemeter. PLL unit consists of NE564 and 74LS193.The movable reflector of the wavemeter is driven by a voice-coin motor. The closed loop feedback design can ensure the movable reflector to move in constant speed all the time. Experiment results show that precision of this wavemeter is super to 1×10-6, approaching to 2×10-7.

  11. Computer Controlled High Precise,High Voltage Pules Generator

    Institute of Scientific and Technical Information of China (English)

    但果; 邹积岩; 丛吉远; 董恩源

    2003-01-01

    High precise, high voltage pulse generator made up of high-power IGBT and pulse transformers controlled by a computer are described. A simple main circuit topology employed in this pulse generator can reduce the cost meanwhile it still meets special requirements for pulsed electric fields (PEFs) in food process. The pulse generator utilizes a complex programmable logic device (CPLD) to generate trigger signals. Pulse-frequency, pulse-width and pulse-number are controlled via RS232 bus by a computer. The high voltage pulse generator well suits to the application for fluid food non-thermal effect in pulsed electric fields, for it can increase and decrease by the step length 1.

  12. Real-time monitoring of high-intensity focused ultrasound treatment using axial strain and axial-shear strain elastograms.

    Science.gov (United States)

    Xia, Rongmin; Thittai, Arun K

    2014-03-01

    Axial strain elastograms (ASEs) have been found to help visualize sonographically invisible thermal lesions. However, in most studies involving high-intensity focused ultrasound (HIFU)-induced thermal lesions, elastography imaging was performed separately later, after the lesion was formed. In this article, the feasibility of monitoring, in real time, tissue elasticity variation during HIFU treatment and immediately thereafter is explored using quasi-static elastography. Further, in addition to ASEs, we also explore the use of simultaneously acquired axial-shear strain elastograms (ASSEs) for HIFU lesion visualization. Experiments were performed on commercial porcine liver samples in vitro. The HIFU experiments were conducted at two applied acoustic power settings, 35 and 20 W. The experimental setup allowed us to interrupt the HIFU pulse momentarily several different times during treatment to perform elastographic compression and data acquisition. At the end of the experiments, the samples were cut along the imaging plane and photographed to compare size and location of the formed lesion with those visualized on ASEs and ASSEs. Single-lesion and multiple-lesion experiments were performed to assess the contribution of ASEs and ASSEs to lesion visualization and treatment monitoring tasks. At both power settings, ASEs and ASSEs provided accurate location information during HIFU treatment. At the low-power setting case, ASEs and ASSEs provide accurate lesion size in real-time monitoring. Lesion appearance in ASEs and ASSEs was affected by the cavitation bubbles produced at the high-power setting. The results further indicate that the cavitation bubbles influence lesion appearance more in ASEs than in ASSEs. Both ASEs and ASSEs provided accurate size information after a waiting period that allowed the cavitation bubbles to disappear. The results indicate that ASSEs not only improve lesion visualization and size measurement of a single lesion, but, under certain

  13. High precision droplet based new form manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Aceves,S; Hadjiconstantinou, N; Miller, W O; Orme, M; Sahai, V; Shapiro, A B

    1999-09-16

    In collaboration with the University of California at Irvine (UCI), we are working on a new technology that relies on the precise deposition of nanoliter molten-metal droplets that are targeted onto a substrate by electrostatic charging and deflection. By this way, three-dimensional (3D) structural materials can be manufactured microlayer by microlayer. Because the volume of the droplets are small, they rapidly solidify on impact, bringing forth a material component with fine grain structures which lead to enhanced material properties (e.g., strength). UCI is responsible for an experimental investigation of the manufacturing feasibility of this process. LLNL has unique expertise in the computational modeling of 3D heat transfer and solid mechanics and has the large-scale computer resources necessary to model this large system. Process modeling will help move this technology from the bench-top to an industrial process. Applications at LLNL include rapid prototyping of metal parts and manufacturing new alloys by co-jetting different metals.

  14. Estimation of the Axial Stress in High-Tension Bolt by Acoustoelastic Method

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Hae Hwa; Lee, Tae Hoon; Jhang, Kyung Young [Hanyang University, Seoul (Korea, Republic of); Kim, Noh Yu [Korea University of Technology and Education, Cheonan (Korea, Republic of)

    2006-10-15

    The evaluation of clamping condition has been regarded as the main issue in the safety-maintenance of the clamped high-tension bolts. For this, this paper proposes a method to estimate the axial stress by measuring the Tofu (Time-Of-Flight) of ultrasonic wave, which is based on the acetylsalicylate or the dependency of sound speed on the stress. In this method, however, the variation of sound speed within the range of stress induced under the field condition is very small, and thus the accuracy of the Tofu measurement is important. We adopted the phase detection method using tone-burst ultrasonic wave to measure the precise Tofu. In order to verify the usefulness of the proposed method experiments are carried out and the results were compared with the stress measured by the strain gage. The results show good agreement with each other, and from these we can conclude that the proposed method is highly useful fnr the evaluation of clamping condition in the clamped high-tension bolts

  15. Design of High Precision Temperature Measurement System based on Labview

    OpenAIRE

    Weimin Zhu; Jin Liu; Haima Yang; Chaochao Yan

    2015-01-01

    Using the LabVIEW software platform, a high precision temperature measuring device is designed based on the principle of the thermocouple. The system uses the STM32 MCU as the main control chip, using AD7076 analog digital converter. The converter has 8 channel, synchronous sampling, and bipolar input. Improving the precision of temperature measurement by cold end compensation, fitting and other measures. The test results show that, the device temperature measurement precision can reach ±0.1 ...

  16. High-Precision Spectroscopy of Pulsating Stars

    CERN Document Server

    Aerts, C; Desmet, M; Carrier, F; Zima, W; Briquet, M; De Ridder, J

    2007-01-01

    We review methodologies currently available to interprete time series of high-resolution high-S/N spectroscopic data of pulsating stars in terms of the kind of (non-radial) modes that are excited. We illustrate the drastic improvement of the detection treshold of line-profile variability thanks to the advancement of the instrumentation over the past two decades. This has led to the opportunity to interprete line-profile variations with amplitudes of order m/s, which is a factor 1000 lower than the earliest line-profile time series studies allowed for.

  17. Active vibration isolation of high precision machines

    CERN Document Server

    Collette, C; Artoos, K; Hauviller, C

    2010-01-01

    This paper provides a review of active control strategies used to isolate high precisionmachines (e.g. telescopes, particle colliders, interferometers, lithography machines or atomic force microscopes) from external disturbances. The objective of this review is to provide tools to develop the best strategy for a given application. Firstly, the main strategies are presented and compared, using single degree of freedom models. Secondly, the case of huge structures constituted of a large number of elements, like particle colliders or segmented telescopes, is considered.

  18. High-precision gauging of metal rings

    Science.gov (United States)

    Carlin, Mats; Lillekjendlie, Bjorn

    1994-11-01

    Raufoss AS designs and produces air brake fittings for trucks and buses on the international market. One of the critical components in the fittings is a small, circular metal ring, which is going through 100% dimension control. This article describes a low-price, high accuracy solution developed at SINTEF Instrumentation based on image metrology and a subpixel resolution algorithm. The measurement system consists of a PC-plugg-in transputer video board, a CCD camera, telecentric optics and a machine vision strobe. We describe the measurement technique in some detail, as well as the robust statistical techniques found to be essential in the real life environment.

  19. High precision mass measurements for wine metabolomics

    Science.gov (United States)

    Roullier-Gall, Chloé; Witting, Michael; Gougeon, Régis; Schmitt-Kopplin, Philippe

    2014-11-01

    An overview of the critical steps for the non-targeted Ultra-High Performance Liquid Chromatography coupled with Quadrupole Time-of-Flight Mass Spectrometry (UPLC-Q-ToF-MS) analysis of wine chemistry is given, ranging from the study design, data preprocessing and statistical analyses, to markers identification. UPLC-Q-ToF-MS data was enhanced by the alignment of exact mass data from FTICR-MS, and marker peaks were identified using UPLC-Q-ToF-MS². In combination with multivariate statistical tools and the annotation of peaks with metabolites from relevant databases, this analytical process provides a fine description of the chemical complexity of wines, as exemplified in the case of red (Pinot noir) and white (Chardonnay) wines from various geographic origins in Burgundy.

  20. Precision timing calorimeter for high energy physics

    Science.gov (United States)

    Anderson, Dustin; Apresyan, Artur; Bornheim, Adolf; Duarte, Javier; Peña, Cristián; Spiropulu, Maria; Trevor, Jason; Xie, Si; Ronzhin, Anatoly

    2016-07-01

    Scintillator based calorimeter technology is studied with the aim to achieve particle detection with a time resolution on the order of a few 10 ps for photons and electrons at energies of a few GeV and above. We present results from a prototype of a 1.4×1.4×11.4 cm3 sampling calorimeter cell consisting of tungsten absorber plates and Cerium-doped Lutetium Yttrium Orthosilicate (LYSO) crystal scintillator plates. The LYSO plates are read out with wave lengths shifting fibers which are optically coupled to fast photo detectors on both ends of the fibers. The measurements with electrons were performed at the Fermilab Test Beam Facility (FTBF) and the CERN SPS H2 test beam. In addition to the baseline setup plastic scintillation counter and a MCP-PMT were used as trigger and as a reference for a time of flight measurement (TOF). We also present measurements with a fast laser to further characterize the response of the prototype and the photo sensors. All data were recorded using a DRS4 fast sampling digitizer. These measurements are part of an R&D program whose aim is to demonstrate the feasibility of building a large scale electromagnetic calorimeter with a time resolution on the order of 10 ps, to be used in high energy physics experiments.

  1. Precision timing calorimeter for high energy physics

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Dustin; Apresyan, Artur [California Institute of Technology, Pasadena, CA 91125 (United States); Bornheim, Adolf, E-mail: bornheim@hep.caltech.edu [California Institute of Technology, Pasadena, CA 91125 (United States); Duarte, Javier; Peña, Cristián; Spiropulu, Maria; Trevor, Jason; Xie, Si [California Institute of Technology, Pasadena, CA 91125 (United States); Ronzhin, Anatoly [Fermi National Accelerator Laboratory, PO Box 500, Batavia, IL 60510-5011 (United States)

    2016-07-11

    Scintillator based calorimeter technology is studied with the aim to achieve particle detection with a time resolution on the order of a few 10 ps for photons and electrons at energies of a few GeV and above. We present results from a prototype of a 1.4×1.4×11.4 cm{sup 3} sampling calorimeter cell consisting of tungsten absorber plates and Cerium-doped Lutetium Yttrium Orthosilicate (LYSO) crystal scintillator plates. The LYSO plates are read out with wave lengths shifting fibers which are optically coupled to fast photo detectors on both ends of the fibers. The measurements with electrons were performed at the Fermilab Test Beam Facility (FTBF) and the CERN SPS H2 test beam. In addition to the baseline setup plastic scintillation counter and a MCP-PMT were used as trigger and as a reference for a time of flight measurement (TOF). We also present measurements with a fast laser to further characterize the response of the prototype and the photo sensors. All data were recorded using a DRS4 fast sampling digitizer. These measurements are part of an R&D program whose aim is to demonstrate the feasibility of building a large scale electromagnetic calorimeter with a time resolution on the order of 10 ps, to be used in high energy physics experiments.

  2. High Efficiency Axial Deep Creep-Feed Grinding Machining Technology of Engineering Ceramics Materials

    Institute of Scientific and Technical Information of China (English)

    GUO Fang; ZHANG Baoguo; LU Hong; TIAN Xinli; WANG Jianquan; LI Fuqiang

    2012-01-01

    Axial deep creep-feed grinding machining technology is a high efficiency process method of engineering ceramics materials,which is an original method to process the cylindrical ceramics materials or hole along its axis.The analysis of axial force and edge fracture proved the cutting thickness and feed rate could be more than 5-10 mm and 200 mm/min respectively in once process,and realized high efficiency,low-cost process of engineering ceramics materials.Compared with high speed-deep grinding machining,this method is also a high efficiency machining technology of engineering ceramics materials as well as with low cost.In addition,removal mechanism analyses showed that both median/radial cracks and lateral cracks appeared in the part to be removed,and the processed part is seldom destroyed,only by adjusting the axial force to control the length of transverse cracks.

  3. Galvanometer deflection: a precision high-speed system.

    Science.gov (United States)

    Jablonowski, D P; Raamot, J

    1976-06-01

    An X-Y galvanometer deflection system capable of high precision in a random access mode of operation is described. Beam positional information in digitized form is obtained by employing a Ronchi grating with a sophisticated optical detection scheme. This information is used in a control interface to locate the beam to the required precision. The system is characterized by high accuracy at maximum speed and is designed for operation in a variable environment, with particular attention placed on thermal insensitivity.

  4. High precision modeling at the 10^{-20} level

    CERN Document Server

    Andres, M; Costea, A; Hackmann, E; Herrmann, S; Lämmerzahl, C; Nesemann, L; Rievers, B; Stephan, E P

    2011-01-01

    The requirements for accurate numerical simulation are increasing constantly. Modern high precision physics experiments now exceed the achievable numerical accuracy of standard commercial and scientific simulation tools. One example are optical resonators for which changes in the optical length are now commonly measured to 10^{-15} precision. The achievable measurement accuracy for resonators and cavities is directly influenced by changes in the distances between the optical components. If deformations in the range of 10^{-15} occur, those effects cannot be modeled and analysed any more with standard methods based on double precision data types. New experimental approaches point out that the achievable experimental accuracies may improve down to the level of 10^{-17} in the near future. For the development and improvement of high precision resonators and the analysis of experimental data, new methods have to be developed which enable the needed level of simulation accuracy. Therefore we plan the development o...

  5. A rotational and axial motion system load frame insert for in situ high energy x-ray studies

    Energy Technology Data Exchange (ETDEWEB)

    Shade, Paul A., E-mail: paul.shade.1@us.af.mil; Schuren, Jay C.; Turner, Todd J. [Materials and Manufacturing Directorate, Air Force Research Laboratory, Wright-Patterson AFB, Ohio 45433 (United States); Blank, Basil [PulseRay, Beaver Dams, New York 14812 (United States); Kenesei, Peter; Goetze, Kurt; Lienert, Ulrich; Almer, Jonathan [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Suter, Robert M. [Carnegie Mellon University, Pittsburgh, Pennsylvania 15213 (United States); Bernier, Joel V.; Li, Shiu Fai [Engineering Directorate, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Lind, Jonathan [Carnegie Mellon University, Pittsburgh, Pennsylvania 15213 (United States); Engineering Directorate, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2015-09-15

    High energy x-ray characterization methods hold great potential for gaining insight into the behavior of materials and providing comparison datasets for the validation and development of mesoscale modeling tools. A suite of techniques have been developed by the x-ray community for characterizing the 3D structure and micromechanical state of polycrystalline materials; however, combining these techniques with in situ mechanical testing under well characterized and controlled boundary conditions has been challenging due to experimental design requirements, which demand new high-precision hardware as well as access to high-energy x-ray beamlines. We describe the design and performance of a load frame insert with a rotational and axial motion system that has been developed to meet these requirements. An example dataset from a deforming titanium alloy demonstrates the new capability.

  6. High precision spectroscopy and imaging in THz frequency range

    Science.gov (United States)

    Vaks, Vladimir L.

    2014-03-01

    Application of microwave methods for development of the THz frequency range has resulted in elaboration of high precision THz spectrometers based on nonstationary effects. The spectrometers characteristics (spectral resolution and sensitivity) meet the requirements for high precision analysis. The gas analyzers, based on the high precision spectrometers, have been successfully applied for analytical investigations of gas impurities in high pure substances. These investigations can be carried out both in absorption cell and in reactor. The devices can be used for ecological monitoring, detecting the components of chemical weapons and explosive in the atmosphere. The great field of THz investigations is the medicine application. Using the THz spectrometers developed one can detect markers for some diseases in exhaled air.

  7. Bounding the Probability of Error for High Precision Recognition

    CERN Document Server

    Kae, Andrew; Learned-Miller, Erik

    2009-01-01

    We consider models for which it is important, early in processing, to estimate some variables with high precision, but perhaps at relatively low rates of recall. If some variables can be identified with near certainty, then they can be conditioned upon, allowing further inference to be done efficiently. Specifically, we consider optical character recognition (OCR) systems that can be bootstrapped by identifying a subset of correctly translated document words with very high precision. This "clean set" is subsequently used as document-specific training data. While many current OCR systems produce measures of confidence for the identity of each letter or word, thresholding these confidence values, even at very high values, still produces some errors. We introduce a novel technique for identifying a set of correct words with very high precision. Rather than estimating posterior probabilities, we bound the probability that any given word is incorrect under very general assumptions, using an approximate worst case ...

  8. The concept of a plasma centrifuge with a high frequency rotating magnetic field and axial circulation

    Science.gov (United States)

    Borisevich, V. D.; Potanin, E. P.

    2017-07-01

    The possibility of using a rotating magnetic field (RMF) in a plasma centrifuge (PC), with axial circulation to multiply the radial separation effect in an axial direction, is considered. For the first time, a traveling magnetic field (TMF) is proposed to drive an axial circulation flow in a PC. The longitudinal separation effect is calculated for a notional model, using specified operational parameters and the properties of a plasma, comprising an isotopic mixture of 20Ne-22Ne and generated by a high frequency discharge. The optimal intensity of a circulation flow, in which the longitudinal separation effect reaches its maximum value, is studied. The optimal parameters of the RMF and TMF for effective separation, as well as the centrifuge performance, are calculated.

  9. Dynamic coefficients of axial spline couplings in high-speed rotating machinery

    Energy Technology Data Exchange (ETDEWEB)

    Ku, C.P.R.; Walton, J.F. Jr. (Mechanical Technology Inc., Latham, NY (United States)); Lund, J.W. (Technical Univ. of Denmark, Lyngby (Denmark). Dept. of Machine Elements)

    1994-07-01

    This paper provided the first opportunity to quantify the angular stiffness and equivalent viscous damping coefficients of an axial spline coupling used in high-speed turbomachinery. The bending moments and angular deflections transmitted across an axial spline coupling were measured while a nonrotating shaft was excited by an external shaker. A rotordynamics computer program was used to simulate the test conditions and to correlate the angular stiffness and damping coefficients. The effects of external force and frequency were also investigated. The angular stiffness and damping coefficients were used to perform a linear steady-state rotordynamics stability analysis, and the unstable natural frequency was calculated and compared to the experimental measurements.

  10. The AX-PET project Demonstration of a high resolution axial 3D PET

    CERN Document Server

    Bolle, E; Casella, C; Chesi, E; Clinthorne, N; Cochran, E; De Leo, R; Dissertori, G; Djambazov, G; Fanti, V; Honscheid, K; Huh, S; Johnson, I; Joram, C; Kagan, H; Lustermann, W; Meddi, F; Nappi, E; Nessi-Tedaldi, F; Oliver, J F; Pauss, P; Rafecas, M; Renker, D; Rudge, A; Schinzel, D; Schneider, T; Seguinot, J; Smith, S; Solevi, P; Stapnes, S; Weilhammer, P

    2010-01-01

    The AX-PET is a new geometrical concept for a high resolution 3D PET scanner, based on matrices of axially oriented LYSO crystals interleaved by stacks of WLS, both individually read out by G-APDs. A PET demonstrator, based on two detector modules used in coincidence, is currently under construction.

  11. High current precision long pulse electron beam position monitor

    CERN Document Server

    Nelson, S D; Fessenden, T J; Holmes, C

    2000-01-01

    Precision high current long pulse electron beam position monitoring has typically experienced problems with high Q sensors, sensors damped to the point of lack of precision, or sensors that interact substantially with any beam halo thus obscuring the desired signal. As part of the effort to develop a multi-axis electron beam transport system using transverse electromagnetic stripline kicker technology, it is necessary to precisely determine the position and extent of long high energy beams for accurate beam position control (6 - 40 MeV, 1 - 4 kA, 2 μs beam pulse, sub millimeter beam position accuracy.) The kicker positioning system utilizes shot-to-shot adjustments for reduction of relatively slow (< 20 MHz) motion of the beam centroid. The electron beams passing through the diagnostic systems have the potential for large halo effects that tend to corrupt position measurements.

  12. Preparing polished crystal slices with high precision orientation

    DEFF Research Database (Denmark)

    Mathiesen, S. Ipsen; Gerward, Leif; Pedersen, O.

    1974-01-01

    A polishing procedure is described which utilizes a high precision Laue technique for crystal orientation. Crystal slices with their final polished surfaces parallel to a crystallographic plane within 0.02° can be prepared. ©1974 The American Institute of Physics......A polishing procedure is described which utilizes a high precision Laue technique for crystal orientation. Crystal slices with their final polished surfaces parallel to a crystallographic plane within 0.02° can be prepared. ©1974 The American Institute of Physics...

  13. Intellective high-precision macromolecule resistance temperature/humidity instrument

    Science.gov (United States)

    Liu, Guixiong; Zhou, Qinhe; Kuang, Yongcong; Xu, Jing; Zeng, Zhixin

    2001-09-01

    Considering that the resistance of macromolecule resistor varies in a wide range and humidity sensor component is sensitive to temperature as well, a intelligent high- precision macromolecule resistance temperature/humidity instrument was proposed in this paper, the instrument is based on the integration of frequency-and-period-measuring method, and sensing characteristic calculation and compensation using interpolation. Practical applications show that the instrument has the advantages of high precision, simple peripheral circuit, low cost, suitability for remote measurement, strong ability of anti-interference and wide operation range.

  14. Design considerations of high precision 6-HTRT parallel manipulator

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xiu-feng; SUN Li-ning

    2006-01-01

    Describes a new architecture of a parallel robot with six degrees of freedom and focuses on improving orientation accuracy of movable platform in mechanism, error correction and control methods. A set of formulations about inverse kinematics, Jacobin matrix, and forward kinematics for the high precision 6-HTRT parallel robots is presented. The analysis of errors existing in the manipulator is discussed and a novel approach for error correction is advanced. By DSP technique, inverse kinematics is solved in real time conditions with high precision and the hardware control system is given. The experimental results demonstrate the effectiveness of the proposed technique.

  15. Design and control of a high precision drive mechanism

    Science.gov (United States)

    Pan, Bo; He, Yongqiang; Wang, Haowei; Zhang, Shuyang; Zhang, Donghua; Wei, Xiaorong; Jiang, Zhihong

    2017-01-01

    This paper summarizes the development of a high precision drive mechanism (HPDM) for space application, such as the directional antenna, the laser communication device, the mobile camera and other pointing mechanisms. In view of the great practical significance of high precision drive system, control technology for permanent magnet synchronous motor (PMSM) servo system is also studied and a PMSM servo controller is designed in this paper. And the software alignment was applied to the controller to eliminate the steady error of the optical encoder, which helps to realize the 1 arcsec (1σ) control precision. To assess its capabilities, the qualification environment testing including the thermal vacuum cycling testing, and the sinusoidal and random vibration were carried out. The testing results show that the performance of the HPDM is almost the same between the former and the end of each testing.

  16. Improving axial resolution in confocal microscopy with new high refractive index mounting media.

    Directory of Open Access Journals (Sweden)

    Coralie Fouquet

    Full Text Available Resolution, high signal intensity and elevated signal to noise ratio (SNR are key issues for biologists who aim at studying the localisation of biological structures at the cellular and subcellular levels using confocal microscopy. The resolution required to separate sub-cellular biological structures is often near to the resolving power of the microscope. When optimally used, confocal microscopes may reach resolutions of 180 nm laterally and 500 nm axially, however, axial resolution in depth is often impaired by spherical aberration that may occur due to refractive index mismatches. Spherical aberration results in broadening of the point-spread function (PSF, a decrease in peak signal intensity when imaging in depth and a focal shift that leads to the distortion of the image along the z-axis and thus in a scaling error. In this study, we use the novel mounting medium CFM3 (Citifluor Ltd., UK with a refractive index of 1.518 to minimize the effects of spherical aberration. This mounting medium is compatible with most common fluorochromes and fluorescent proteins. We compare its performance with established mounting media, harbouring refractive indices below 1.500, by estimating lateral and axial resolution with sub-resolution fluorescent beads. We show furthermore that the use of the high refractive index media renders the tissue transparent and improves considerably the axial resolution and imaging depth in immuno-labelled or fluorescent protein labelled fixed mouse brain tissue. We thus propose to use those novel high refractive index mounting media, whenever optimal axial resolution is required.

  17. High precision module for Chaos Many-Body Engine

    CERN Document Server

    Grossu, I V; Felea, D; Jipa, Al

    2014-01-01

    In this paper we present a C# high precision relativistic many-body module integrated with Chaos Many-Body Engine. As a direct application, we used it for estimating the butterfly effect involved by the gravitational force in a specific nuclear relativistic collision toy-model.

  18. Adaptive Iterative Learning Control for High Precision Motion Systems

    NARCIS (Netherlands)

    Rotariu, I.; Steinbuch, M.; Ellenbroek, R.

    2008-01-01

    Iterative learning control (ILC) is a very effective technique to reduce systematic errors that occur in systems that repetitively perform the same motion or operation. However, several characteristics have prevented standard ILC from being widely used for high precision motion systems. Most importa

  19. High-Precision Spectroscopy with Counter-Propagating Femtosecond Pulses

    CERN Document Server

    Barmes, Itan; Eikema, Kjeld S E

    2013-01-01

    An experimental realization of high-precision direct frequency comb spectroscopy using counter-propagating femtosecond pulses on two-photon atomic transitions is presented. Doppler broadened background signal, hampering precision spectroscopy with ultrashort pulses, is effectively eliminated with a simple pulse shaping method. As a result, all four 5S-7S two-photon transitions in a rubidium vapor are determined with both statistical and systematic uncertainties below 10$^{-11}$, which is an order of magnitude better than previous experiments on these transitions.

  20. GENERATION AND CONTROL OF HIGH PRECISION BEAMS AT LEPTON ACCELERATORS

    Energy Technology Data Exchange (ETDEWEB)

    Yu-Chiu Chao

    2007-06-25

    Parity violation experiments require precision manipulation of helicity-correlated beam coordinates on target at the nm/nrad-level. Achieving this unprecedented level of control requires a detailed understanding of the particle optics and careful tuning of the beam transport to keep anomalies from compromising the design adiabatic damping. Such efforts are often hindered by machine configuration and instrumentation limitations at the low energy end. A technique has been developed at CEBAF including high precision measurements, Mathematica-based analysis for obtaining corrective solutions, and control hardware/software developments for realizing such level of control at energies up to 5 GeV.

  1. Calibration of the TWIST high-precision drift chambers

    CERN Document Server

    Grossheim, A; Olin, A; 10.1016/j.nima.2010.08.105

    2010-01-01

    A method for the precise measurement of drift times for the high-precision drift chambers used in the TWIST detector is described. It is based on the iterative correction of the space-time relationships by the time residuals of the track fit, resulting in a measurement of the effective drift times. The corrected drift time maps are parametrised individually for each chamber using spline functions. Biases introduced by the reconstruction itself are taken into account as well, making it necessary to apply the procedure to both data and simulation. The described calibration is shown to improve the reconstruction performance and to extend significantly the physics reach of the experiment.

  2. High Precision Time Domain Forward Modeling for Crosshole Electromagnetic Tomography

    Institute of Scientific and Technical Information of China (English)

    Lin Shuhai; Zhao Liying

    2007-01-01

    To improve the resolution of crosshole electromagnetic tomography, high precision of forward modeling is necessary. A pseudo-spectral time domain (PSTD) forward modeling was used to simulate electromagnetic wave propagation between two boreholes. The PSTD algorithm is based on the finite difference time domain (FDTD) method and uses the fast Fourier transform (FFT) algorithm for spatial derivatives in Maxwell's equations. Besides having the strongpoint of the FDTD method, the calculation precision of the PSTD algorithm is higher than that of the FDTD method under the same calculation condition. The forward modeling using the PSTD method will play an important role in enhancing the resolution of crosshole electromagnetic tomography.

  3. A high resolution TOF-PET concept with axial geometry and digital SiPM readout

    CERN Document Server

    Casella, C; Joram, C; Schneider, T

    2014-01-01

    The axial arrangement of long scintillation crystals is a promising concept in PET instrumentation to address the need for optimized resolution and sensitivity. Individual crystal readout and arrays of wavelength shifter strips placed orthogonally to the crystals lead to a 3D-detection of the annihilations photons. A fully operational demonstrator scanner, developed by the AX-PET collaboration, proved the potential of this concept in terms of energy and spatial resolution as well as sensitivity. This paper describes a feasibility study, performed on axial prototype detector modules with 100 mm long LYSO crystals, read out by the novel digital Silicon Photomultipliers (dSiPM) from Philips. With their highly integrated readout electronics and excellent intrinsic time resolution, dSiPMs allow for compact, axial detector modules which may extend the potential of the axial PET concept by time of fl ight capabilities (TOF-PET). A coincidence time resolution of 211 ps (FWHM) was achieved in the coincidence of two ax...

  4. Research on a novel high stiffness axial passive magnetic bearing for DGMSCMG

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Jinji [Key Laboratory of Fundamental Science for National Defense, Novel Inertial Instrument and Navigation System Technology, School of Instrument Science and Opto-electronics Engineering, Beihang University, 100191 (China); Wang, Chun' e [Beijing Institute of Automatic Control Equipment, 100074 (China); Le, Yun [Key Laboratory of Fundamental Science for National Defense, Novel Inertial Instrument and Navigation System Technology, School of Instrument Science and Opto-electronics Engineering, Beihang University, 100191 (China)

    2016-08-15

    To increase the displacement stiffness and decrease power loss of double gimbals magnetically suspended control momentum gyro (DGMSCMG), this paper researches a new structure of axial passive magnetic bearing (APMB). Different from the existing APMB, the proposed APMB is composed of segmented permanent magnets and magnetic rings. The displacement stiffness and angular stiffness expressions are derived by equivalent magnetic circuit method and infinitesimal method based on the end magnetic flux. The relationships are analyzed between stiffness and structure parameters such as length of air gap, length of permanent magnet, height of permanent magnet and end length of magnetic ring. Besides, the axial displacement stiffness measurement method of the APMB is proposed, and it verified the correctness of proposed theoretical method. The DGMSCMG prototype is manufactured and the slow-down characteristic experiment is carried out, and the experimental result reflects the low power loss feature of the APMB. - Highlights: • A novel high stiffness axial passive magnetic bearing for DGMSCMG. • The proposed APMB is composed of segmented permanent magnets and magnetic rings. • The APMB is analyzed by EMCM and infinitesimal method based on the end magnetic flux. • The axial displacement stiffness measurement method of the APMB is proposed. • The DGMSCMG is manufactured and proved the correctness of theoretical analysis.

  5. High-speed measurement of axial grain transport in a rotating drum

    Science.gov (United States)

    van Bussel, Frank; Khan, Zeina; Schaber, Marc; Seemann, Ralf; Scheel, Mario; Dimichiel, Marco

    2012-02-01

    Over short timescales granular mixtures separate by size when tumbled in a partially filled horizontal drum. The smaller grains move toward the axis of rotation to form a central core; undulations in this core gradually increase in amplitude until they grow into axial bands. Using non-invasive high-speed synchrotron x-ray particle tracking, we investigate the axial transport properties of tracer particles traveling amongst glass spheres. This new technique allows us to gather data on time scales not previously possible. When the tracers are present in larger proportions the mixtures we used should have different tendencies to segregate axially according to size ratio; one of our findings, however, is that when the tracer concentration is low the single-particle dynamics of these mixtures do not depend on the relative particle sizes in any appreciable way. This implies that the potential for a mixture to axially segregate cannot be inferred from the microscopic dynamics of individual small particles. A second finding is that while the slope of the mean-squared displacement is close to that expected from diffusive transport, as determined from the single-particle dynamics, more detailed analyses indicate anomalous transport.

  6. Analysis of a Liquid Nitrogen-Cooled Tri-Axial High-Temperature Superconducting Cable System

    Science.gov (United States)

    Demko, J. A.; Lue, J. W.; Gouge, M. J.; Fisher, P. W.; Lindsay, D.; Roden, M.

    2004-06-01

    This tri-axial high-temperature superconducting (HTS) cable design uses three concentric superconducting layers for the phase conductors, separated by a cold dielectric material. The design offers an efficient HTS cable configuration by reducing the amount of superconductor needed and places all three phases in a single cryostat. The tri-axial cable cooling circuit analyzed includes heat loads at the ends for the cable terminations and cable heat loads due to ac, dielectric, and thermal losses. The HTS cable critical current and ac loss are functions of the local temperature that must be determined by the analysis. The radial heat transfer also has an influence on these parameters due to the relatively low thermal conductivity of the dielectric material separating the HTS phases. The study investigates whether the tri-axial cable must be cooled both inside the former and outside of the cable. In this study, the range of operating parameters for a tri-axial HTS cable system and refrigeration requirements are determined based on expected HTS tape performance.

  7. High Efficiency Positron Accumulation for High-Precision Measurements

    CERN Document Server

    Hoogerheide, S Fogwell; Novitski, E; Gabrielse, G

    2015-01-01

    Positrons are accumulated within a Penning trap designed to make more precise measurements of the positron and electron magnetic moments. The retractable radioactive source used is weak enough to require no license for handling radioactive material and the radiation dosage one meter from the source gives an exposure several times smaller than the average radiation dose on the earth's surface. The 100 mK trap is mechanically aligned with the 4.2 K superconducting solenoid that produces a 6 tesla magnetic trapping field with a direct mechanical coupling.

  8. Nucleosynthesis Predictions and High-Precision Deuterium Measurements

    Directory of Open Access Journals (Sweden)

    Signe Riemer-Sørensen

    2017-05-01

    Full Text Available Two new high-precision measurements of the deuterium abundance from absorbers along the line of sight to the quasar PKS1937–1009 were presented. The absorbers have lower neutral hydrogen column densities (N(HI ≈ 18 cm − 2 than for previous high-precision measurements, boding well for further extensions of the sample due to the plenitude of low column density absorbers. The total high-precision sample now consists of 12 measurements with a weighted average deuterium abundance of D/H = 2 . 55 ± 0 . 02 × 10 − 5 . The sample does not favour a dipole similar to the one detected for the fine structure constant. The increased precision also calls for improved nucleosynthesis predictions. For that purpose we have updated the public AlterBBN code including new reactions, updated nuclear reaction rates, and the possibility of adding new physics such as dark matter. The standard Big Bang Nucleosynthesis prediction of D/H = 2 . 456 ± 0 . 057 × 10 − 5 is consistent with the observed value within 1.7 standard deviations.

  9. Precision glass molding of high-resolution diffractive optical elements

    Science.gov (United States)

    Prater, Karin; Dukwen, Julia; Scharf, Toralf; Herzig, Hans P.; Plöger, Sven; Hermerschmidt, Andreas

    2016-04-01

    The demand of high resolution diffractive optical elements (DOE) is growing. Smaller critical dimensions allow higher deflection angles and can fulfill more demanding requirements, which can only be met by using electron-beam lithography. Replication techniques are more economical, since the high cost of the master can be distributed among a larger number of replicas. The lack of a suitable mold material for precision glass molding has so far prevented an industrial use. Glassy Carbon (GC) offers a high mechanical strength and high thermal strength. No anti-adhesion coatings are required in molding processes. This is clearly an advantage for high resolution, high aspect ratio microstructures, where a coating with a thickness between 10 nm and 200 nm would cause a noticeable rounding of the features. Electron-beam lithography was used to fabricate GC molds with highest precision and feature sizes from 250 nm to 2 μm. The master stamps were used for precision glass molding of a low Tg glass L-BAL42 from OHARA. The profile of the replicated glass is compared to the mold with the help of SEM images. This allows discussion of the max. aspect-ratio and min. feature size. To characterize optical performances, beamsplitting elements are fabricated and their characteristics were investigated, which are in excellent agreement to theory.

  10. Preparation of cold molecules for high-precision measurements

    Science.gov (United States)

    Wall, T. E.

    2016-12-01

    Molecules can be used to test fundamental physics. Such tests often require cold molecules for detailed spectroscopic analysis. Cooling internal degrees of freedom provides a high level of state-selectivity, with large populations in the molecular states of interest. Cold translational motion allows slow, bright beams to be created, allowing long interaction times. In this tutorial article we describe the common techniques for producing cold molecules for high-precision spectroscopy experiments. For each technique we give examples of its application in experiments that use molecular structure to probe fundamental physics, choosing one experiment in particular as a case study. We then discuss a number of new techniques, some currently under development, others proposed, that promise high flux sources of cold molecules applicable to precise spectroscopic tests of fundamental physics.

  11. Design of high-precision ranging system for laser fuze

    Science.gov (United States)

    Chen, Shanshan; Zhang, He; Xu, Xiaobin

    2016-10-01

    According to the problem of the high-precision ranging in the circumferential scanning probe laser proximity fuze, a new type of pulsed laser ranging system has been designed. The laser transmitting module, laser receiving module and ranging processing module have been designed respectively. The factors affecting the ranging accuracy are discussed. And the method of improving the ranging accuracy is studied. The high-precision ranging system adopts the general high performance microprocessor C8051FXXX as the core. And the time interval measurement chip TDC-GP21 was used to implement the system. A PCB circuit board was processed to carry on the experiment. The results of the experiment prove that a centimeter level accuracy ranging system has been achieved. The works can offer reference for ranging system design of the circumferential scanning probe laser proximity fuze.

  12. The numerical simulation of a high-speed axial flow compressor

    Science.gov (United States)

    Mulac, Richard A.; Adamczyk, John J.

    1991-01-01

    The advancement of high-speed axial-flow multistage compressors is impeded by a lack of detailed flow-field information. Recent development in compressor flow modeling and numerical simulation have the potential to provide needed information in a timely manner. The development of a computer program is described to solve the viscous form of the average-passage equation system for multistage turbomachinery. Programming issues such as in-core versus out-of-core data storage and CPU utilization (parallelization, vectorization, and chaining) are addressed. Code performance is evaluated through the simulation of the first four stages of a five-stage, high-speed, axial-flow compressor. The second part addresses the flow physics which can be obtained from the numerical simulation. In particular, an examination of the endwall flow structure is made, and its impact on blockage distribution assessed.

  13. High-precision ground-based photometry of exoplanets

    Directory of Open Access Journals (Sweden)

    de Mooij Ernst J.W.

    2013-04-01

    Full Text Available High-precision photometry of transiting exoplanet systems has contributed significantly to our understanding of the properties of their atmospheres. The best targets are the bright exoplanet systems, for which the high number of photons allow very high signal-to-noise ratios. Most of the current instruments are not optimised for these high-precision measurements, either they have a large read-out overhead to reduce the readnoise and/or their field-of-view is limited, preventing simultaneous observations of both the target and a reference star. Recently we have proposed a new wide-field imager for the Observatoir de Mont-Megantic optimised for these bright systems (PI: Jayawardhana. The instruments has a dual beam design and a field-of-view of 17' by 17'. The cameras have a read-out time of 2 seconds, significantly reducing read-out overheads. Over the past years we have obtained significant experience with how to reach the high precision required for the characterisation of exoplanet atmospheres. Based on our experience we provide the following advice: Get the best calibrations possible. In the case of bad weather, characterise the instrument (e.g. non-linearity, dome flats, bias level, this is vital for better understanding of the science data. Observe the target for as long as possible, the out-of-transit baseline is as important as the transit/eclipse itself. A short baseline can lead to improperly corrected systematic and mis-estimation of the red-noise. Keep everything (e.g. position on detector, exposure time as stable as possible. Take care that the defocus is not too strong. For a large defocus, the contribution of the total flux from the sky-background in the aperture could well exceed that of the target, resulting in very strict requirements on the precision at which the background is measured.

  14. Highly precise and compact ultrahigh vacuum rotary feedthrough

    Science.gov (United States)

    Aiura, Y.; Kitano, K.

    2012-03-01

    The precision and rigidity of compact ultrahigh vacuum (UHV) rotary feedthroughs were substantially improved by preparing and installing an optimal crossed roller bearing with mounting holes. Since there are mounting holes on both the outer and inner races, the bearing can be mounted directly to rotary and stationary stages without any fixing plates and housing. As a result, it is possible to increase the thickness of the bearing or the size of the rolling elements in the bearing without increasing the distance between the rotating and fixing International Conflat flanges of the UHV rotary feedthrough. Larger rolling elements enhance the rigidity of the UHV rotary feedthrough. Moreover, owing to the structure having integrated inner and outer races and mounting holes, the performance is almost entirely unaffected by the installation of the bearing, allowing for a precise optical encoder to be installed in the compact UHV rotary feedthrough. Using position feedback via a worm gear system driven by a stepper motor and a precise rotary encoder, the actual angle of the compact UHV rotary feedthrough can be controlled with extremely high precision.

  15. A high-precision polarimeter for small telescopes

    Science.gov (United States)

    Bailey, Jeremy; Cotton, Daniel V.; Kedziora-Chudczer, Lucyna

    2017-02-01

    We describe Mini-HIPPI (Miniature HIgh Precision Polarimetric Instrument), a stellar polarimeter weighing just 650 gm but capable of measuring linear polarization to ˜10-5. Mini-HIPPI is based on the use of a Ferroelectric Liquid Crystal modulator. It can easily be mounted on a small telescope and allows us to study the polarization of bright stars at levels of precision which are hitherto largely unexplored. We present results obtained with Mini-HIPPI on a 35-cm telescope. Measurements of polarized standard stars are in good agreement with predicted values. Measurements of a number of bright stars agree well with those from other high-sensitivity polarimeters. Observations of the binary system Spica show polarization variability around the orbital cycle.

  16. Precision cosmology with time delay lenses: high resolution imaging requirements

    CERN Document Server

    Meng, Xiao-Lei; Agnello, Adriano; Auger, Matthew W; Liao, Kai; Marshall, Philip J

    2015-01-01

    Lens time delays are a powerful probe of cosmology, provided that the gravitational potential of the main deflector can be modeled with sufficient precision. Recent work has shown that this can be achieved by detailed modeling of the host galaxies of lensed quasars, which appear as "Einstein Rings" in high resolution images. We carry out a systematic exploration of the high resolution imaging required to exploit the thousands of lensed quasars that will be discovered by current and upcoming surveys with the next decade. Specifically, we simulate realistic lens systems as imaged by the Hubble Space Telescope (HST), James Webb Space Telescope (JWST), and ground based adaptive optics images taken with Keck or the Thirty Meter Telescope (TMT). We compare the performance of these pointed observations with that of images taken by the Euclid (VIS), Wide-Field Infrared Survey Telescope (WFIRST) and Large Synoptic Survey Telescope (LSST) surveys. We use as our metric the precision with which the slope $\\gamma'$ of the...

  17. High precision {sup 14}C AMS at CIRCE

    Energy Technology Data Exchange (ETDEWEB)

    Terrasi, Filippo [Dipartimento di Scienze Ambientali, II Universita di Napoli, Via Vivaldi 43, Caserta 81100 (Italy); CIRCE, INNOVA, Via Campi Flegrei 34, Pozzuoli 80078 (Italy)], E-mail: filippo.terrasi@unina2.it; De Cesare, Nicola [Dipartimento di Scienze della Vita, II Universita di Napoli, Via Vivaldi 43, Caserta 81100 (Italy); CIRCE, INNOVA, Via Campi Flegrei 34, Pozzuoli 80078 (Italy); D' Onofrio, Antonio; Lubritto, Carmine; Marzaioli, Fabio [Dipartimento di Scienze Ambientali, II Universita di Napoli, Via Vivaldi 43, Caserta 81100 (Italy); CIRCE, INNOVA, Via Campi Flegrei 34, Pozzuoli 80078 (Italy); Passariello, Isabella [CIRCE, INNOVA, Via Campi Flegrei 34, Pozzuoli 80078 (Italy); Rogalla, Detlef [Institut fuer Experimentalphysik III, Ruhr-Universitaet Bochum, Bochum D-44780 (Germany); Sabbarese, Carlo [Dipartimento di Scienze Ambientali, II Universita di Napoli, Via Vivaldi 43, Caserta 81100 (Italy); CIRCE, INNOVA, Via Campi Flegrei 34, Pozzuoli 80078 (Italy); Borriello, Gianluca; Casa, Giovanni; Palmieri, Antonio [Dipartimento di Scienze Ambientali, II Universita di Napoli, Via Vivaldi 43, Caserta 81100 (Italy)

    2008-05-15

    The CIRCE AMS system started operation in March 2005. The measurement of isotopic ratios {sup 14}C/{sup 12}C in samples of archaeological and environmental interest has rapidly attained high precision and accuracy levels in routine operation. The results of the intercomparison campaign in the framework of the VIRI program, as well as the outcome of a statistical analysis of the about 200 control measurements performed with standard samples, have shown the capability of the whole system for high precision measurements ({delta}R/R < 0.3%), allowing systematic investigations in both archaeological and environmental sciences. {sup 26}Al AMS has been implemented for the measurement of the astrophysically relevant {sup 25}Mg(p,{gamma}){sup 26}Al reaction cross section, while a beam line is under construction for the measurement of actinides isotopic ratios.

  18. Some comments on high precision study of neutrino oscillations

    Science.gov (United States)

    Bilenky, S. M.

    2015-07-01

    I discuss here some problems connected with the high precision study of neutrino oscillations. In the general case of n-neutrino mixing I derive a convenient expression for transition probability in which only independent terms (and mass-squared differences) enter. For three-neutrino mixing I discuss a problem of a definition of a large (atmospheric) neutrino mass-squared difference. I comment also possibilities to reveal the character of neutrino mass spectrum in future reactor neutrino experiments.

  19. High Precision Signal Processing Algorithm for White Light Interferometry

    OpenAIRE

    Kim, Jeonggon Harrison

    2008-01-01

    A new signal processing algorithm for absolute temperature measurement using white light interferometry has been proposed and investigated theoretically. The proposed algorithm determines the phase delay of an interferometer with very high precision (≪ one fringe) by identifying the zero order fringe peak of cross-correlation of two fringe scans of white light interferometer. The algorithm features cross-correlation of interferometer fringe scans, hypothesis testing and fine tuning. The hypot...

  20. High-Precision Computation: Mathematical Physics and Dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, D. H.; Barrio, R.; Borwein, J. M.

    2010-04-01

    At the present time, IEEE 64-bit oating-point arithmetic is suficiently accurate for most scientic applications. However, for a rapidly growing body of important scientic computing applications, a higher level of numeric precision is required. Such calculations are facilitated by high-precision software packages that include high-level language translation modules to minimize the conversion e ort. This pa- per presents a survey of recent applications of these techniques and provides someanalysis of their numerical requirements. These applications include supernova simulations, climate modeling, planetary orbit calculations, Coulomb n-body atomic systems, studies of the one structure constant, scattering amplitudes of quarks, glu- ons and bosons, nonlinear oscillator theory, experimental mathematics, evaluation of orthogonal polynomials, numerical integration of ODEs, computation of periodic orbits, studies of the splitting of separatrices, detection of strange nonchaotic at- tractors, Ising theory, quantum held theory, and discrete dynamical systems. We conclude that high-precision arithmetic facilities are now an indispensable compo- nent of a modern large-scale scientic computing environment.

  1. VCA Direct-Drive High Speed and Precision XY Table

    Institute of Scientific and Technical Information of China (English)

    ZHAO Xingyu; FENG Xiaomei; ZHANG Dawei

    2007-01-01

    In order to compensate for the limitation of conventional XY table used in semiconductor integrated circuits(IC) packaging and improve its speed and accuracy, a voice coil actuator (VCA)direct-drive high-speed and precision positioning XY table used in wire bonder was proposed. Also, a novel flexible decoupling mechanism was used in the positioning table, and the small moving mass enabled the positioning table to move at high speed and precision. XY table deformation interference caused by assembly error and instant interference generated by dynamic load moving with high speed and acceleration can be eliminated through the flexible decoupling mechanism. Considering the positioning table as lumped mass spring system, the dynamic equations of the mechanical sys-tem and the VCA were built according to the Newton mechanics principle and electromagnetic theory. Then the electromechanical coupling control model of the system was created through Laplace transform. Based on displacement PID controller, the Icop-locked controlling algorithm of the positioning system was investigated. The dynamic control algorithm effectively improved the system dynamic performance. The precision test of the prototype machine was carried out, and the results val-idated the correctness of the model and the theory. Compared with traditional XY table, the tablehas higher speed, acceleration and positioning accuracy.

  2. New research trends on high-precision time transfer technology

    Institute of Scientific and Technical Information of China (English)

    DONG; Ruifang; QUAN; Run’ai; HOU; Feiyan; WANG; Shaofeng; XIANG; Xiao; ZHOU; Conghua; WANG; Mengmeng; LIU; Tao; ZHANG; Shou’gang

    2015-01-01

    High-precision time transfer plays an important role in the areas of fundamental research and applications. Accompanying w ith the remarkable improvements in the ability of generating and measuring high-accuracy time-frequency signal,seeking for new time-transfer techniques betw een distant clocks w ith much further improved accuracy attracts attentions w orld-w idely. The time-transfer technique based on optical pulses has the highest precision presently,and the further improvement in the accuracy is heavily dependent on the time-domain properties of the pulse as w ell as the sensitivity of the applied measurement on the exchanged pulse. The application of optical frequency comb in time transfer for a precision up to femtosecond level are currently the focus of much interest,and has recently achieved many breakthroughs. Further investigations show that,utilizing quantum techniques,i.e. quantum measurement technique and quantum optical pulse source,can lead to a new limit on the measured timing information. Furthermore,it can be immune from atmospheric parameters,such as pressure,temperature,humidity and so on.Such quantum improvements on time-transfer have a bright prospect in the future applications requiring extremely high-accuracy timing and ranging. The potential achievements w ill form a technical basis for the future realization of sub-femtosecond time transfer system.

  3. High precision spectroscopy of pionic and antiprotonic atoms; Spectroscopie de precision des atomes pioniques et antiprotoniques

    Energy Technology Data Exchange (ETDEWEB)

    El-Khoury, P

    1998-04-15

    The study of exotic atoms, in which an orbiting electron of a normal atom is replaced by a negatively charged particle ({pi}{sup -}, {mu}{sup -}, p, {kappa}{sup -}, {sigma}{sup -},...) may provide information on the orbiting particle and the atomic nucleus, as well as on their interaction. In this work, we were interested in pionic atoms ({pi}{sup -14} N) on the one hand in order to determine the pion mass with high accuracy (4 ppm), and on the other hand in antiprotonic atoms (pp-bar) in order to study the strong nucleon-antinucleon interaction at threshold. In this respect, a high-resolution crystal spectrometer was coupled to a cyclotron trap which provides a high stop density for particles in gas targets at low pressure. Using curved crystals, an extended X-ray source could be imaged onto the detector. Charge-Coupled Devices were used as position sensitive detectors in order to measure the Bragg angle of the transition to a high precision. The use of gas targets resolved the ambiguity owing to the number of K electrons for the value of the pion mass, and, for the first time, strong interaction shift and broadening of the 2p level in antiprotonic hydrogen were measured directly. (author)

  4. Automated high precision secondary pH measurements

    Science.gov (United States)

    Bastkowski, F.; Jakobsen, P. T.; Stefan, F.; Kristensen, H. B.; Jensen, H. D.; Kawiecki, R.; Wied, C. E.; Kauert, A.; Seidl, B.; Spitzer, P.; Eberhardt, R.; Adel, B.

    2013-04-01

    A new setup for high precision, automated secondary pH measurements together with a reference measurement procedure has been developed and tested in interlaboratory comparisons using buffers pH 4.005, pH 7.000, and pH 10.012 at 25 °C and 37 °C. Using primary buffers as standards, a standard uncertainty in pH better than 0.005 can be reached. The central measuring device is a one piece, thermostatted cell of PFA (perfluoroalkoxy) with a built-in Hamilton® Single Pore™ Glass electrode. Due to its flow-through principle this device allows pH measurements with low consumption of measurement solutions. The very hydrophobic and smooth PFA as construction material facilitates complete emptying of the cell. Furthermore, the tempering unit affords very precise temperature control and hence contributes to the low target uncertainty of the produced secondary buffer solutions. Use of a symmetric measurement sequence and the two point calibration was sufficient to reach high precision and accuracy.

  5. Photonic systems for high precision radial velocity measurements

    Science.gov (United States)

    Halverson, Samuel

    2016-01-01

    I will discuss new instrumentation and techniques designed to maximize the Doppler radial velocity (RV) measurement precision of next generation exoplanet discovery instruments. These systems include a novel wavelength calibration device based on an all-fiber fabry-perot interferometer, a compact and efficient optical fiber image scrambler based on a single high-index ball lens, and a unique optical fiber mode mixer. These systems have been developed specifically to overcome three technological hurdles that have classically hindered high precision RV measurements in both the optical and near-infrared (NIR), namely: lack of available wavelength calibration sources, inadequate decoupling of the spectrograph from variable telescope illumination, and speckle-induced noise due to mode interference in optical fibers. The instrumentation presented here will be applied to the Habitable-zone Planet Finder, a NIR RV instrument designed to detect rocky planets orbiting in the habitable zones of nearby M-dwarfs, and represents a critical technological step towards the detection of potentially habitable Earth-like planets. While primarily focused in the NIR, many of these systems will be adapted to future optical RV instruments as well, such as NASA's new Extreme Precision Doppler Spectrometer for the WIYN telescope.

  6. Intrinsic Instrumental Polarization and High-Precision Pulsar Timing

    CERN Document Server

    Foster, Griffin; Paulin, Remi; Carozzi, Tobia; Johnston, Simon; van Straten, Willem

    2015-01-01

    Radio telescopes are used to accurately measure the time of arrival (ToA) of radio pulses in pulsar timing experiments that target mostly millisecond pulsars (MSPs) due to their high rotational stability. This allows for detailed study of MSPs and forms the basis of experiments to detect gravitational waves. Apart from intrinsic and propagation effects, such as pulse-to-pulse jitter and dispersion variations in the interstellar medium, timing precision is limited in part by the following: polarization purity of the telescope's orthogonally polarized receptors, the signal-to-noise ratio (S/N) of the pulsar profile, and the polarization fidelity of the system. Using simulations, we present how fundamental limitations in recovering the true polarization reduce the precision of ToA measurements. Any real system will respond differently to each source observed depending on the unique pulsar polarization profile. Using the profiles of known MSPs we quantify the limits of observing system specifications that yield s...

  7. Strategies for high-precision Global Positioning System orbit determination

    Science.gov (United States)

    Lichten, Stephen M.; Border, James S.

    1987-01-01

    Various strategies for the high-precision orbit determination of the GPS satellites are explored using data from the 1985 GPS field test. Several refinements to the orbit determination strategies were found to be crucial for achieving high levels of repeatability and accuracy. These include the fine tuning of the GPS solar radiation coefficients and the ground station zenith tropospheric delays. Multiday arcs of 3-6 days provided better orbits and baselines than the 8-hr arcs from single-day passes. Highest-quality orbits and baselines were obtained with combined carrier phase and pseudorange solutions.

  8. Key techniques of the high precision gravity field system

    Science.gov (United States)

    Xu, Weimin; Chen, Shi; Lu, Hongyan; Shi, Lei

    2017-04-01

    Ground-based gravity time series provide a direct method to monitor all sources of mass changes from local to global scale. But the effectively infinite spatial sensitivity of gravity measurements make it difficult to isolate the signal of interest. The high precision gravity field system is an alternative approach of modeling mass changes under-ground. The field system, consists of absolute gravity, gravity and gravity gradient, GNSS, leveling and climate hydrology measurements, can improve the signal-to-noise ratio for many applications by removing contributions of unwanted signal from elevation changes, air pressure changes, local hydrology, and others. The networks of field system combination, such as field-profile in more than 100 kilometers, can be used in critical zone with high seismic risk for monitoring earth dynamics, volcanic and seismic phenomena. The system is constituted by 9 typical observation stations in 3*3 array (or 4 in 2*2 array) in 60 square meters field, each station is designed for integrated measurements, including absolute gravity, gravity gradient, elevation changes, air pressure and hydrology. Time-lapse gravity changes resulting from absolute gravimeter (FG5 or A10) with standard deviation less than 2 μGal, without the contributions of Earth tides, loading and polar motion. Additional measurements such as air pressure change, local hydrology and soil moisture are indispensable. The elevation changes resulting from GNSS (on the base station) and leveling (between stations) with precision less than 10 mm. The gravity gradient is the significant measurement for delimiting the location of the related mass changes underground the station, which is measured by Scintrex CG-5 gravimeters in different height (80cm in the test field), with precision less than 10 E. It is necessary to improve the precision of gravity gradient measurements by certain method in field experiment for the high precision measurement system. Acknowledgment: This

  9. High precision and stable structures for particle detectors

    CERN Document Server

    Da Mota Silva, S; Hauviller, Claude

    1999-01-01

    The central detectors used in High Energy Physics Experiments require the use of light and stable structures capable of supporting delicate and precise radiation detection elements. These structures need to be highly stable under environmental conditions where external vibrations, high radiation levels, temperature and humidity gradients should be taken into account. Their main design drivers are high dimension and dynamic stability, high stiffness to mass ratio and large radiation length. For most applications, these constraints lead us to choose Carbon Fiber Reinforced Plastics ( CFRP) as structural element. The construction of light and stable structures with CFRP for these applications can be achieved by careful design engineering and further confirmation at the prototyping phase. However, the experimental environment can influence their characteristics and behavior. In this case, theuse of adaptive structures could become a solution for this problem. We are studying structures in CFRP with bonded piezoel...

  10. High precision u/th dating of first Polynesian settlement.

    Directory of Open Access Journals (Sweden)

    David Burley

    Full Text Available Previous studies document Nukuleka in the Kingdom of Tonga as a founder colony for first settlement of Polynesia by Lapita peoples. A limited number of radiocarbon dates are one line of evidence supporting this claim, but they cannot precisely establish when this event occurred, nor can they afford a detailed chronology for sequent occupation. High precision U/Th dates of Acropora coral files (abraders from Nukuleka give unprecedented resolution, identifying the founder event by 2838±8 BP and documenting site development over the ensuing 250 years. The potential for dating error due to post depositional diagenetic alteration of ancient corals at Nukuleka also is addressed through sample preparation protocols and paired dates on spatially separated samples for individual specimens. Acropora coral files are widely distributed in Lapita sites across Oceania. U/Th dating of these artifacts provides unparalleled opportunities for greater precision and insight into the speed and timing of this final chapter in human settlement of the globe.

  11. Surface nanoscale axial photonics: Robust fabrication of high quality factor microresonators

    CERN Document Server

    Sumetsky, M; Dulashko, Y; Fini, J M; Liu, X; Monberg, E M; Taunay, T F

    2011-01-01

    Recently introduced Surface Nanoscale Axial Photonics (SNAP) makes it possible to fabricate high Q-factor microresonators and other photonic microdevices by dramatically small deformation of the optical fiber surface. To become a practical and robust technology, the SNAP platform requires methods enabling reproducible modification of the optical fiber radius at nanoscale. In this Letter, we demonstrate super-accurate fabrication of high Q-factor microresonators by nanoscale modification of the optical fiber radius and refractive index using the CO2 laser and the UV excimer laser beam exposures. The achieved fabrication accuracy is better than 2 angstroms in variation of the effective fiber radius.

  12. Precision Muon Tracking Detectors for High-Energy Hadron Colliders

    CERN Document Server

    Gadow, Philipp; Kroha, Hubert; Richter, Robert

    2016-01-01

    Small-diameter muon drift tube (sMDT) chambers with 15 mm tube diameter are a cost-effective technology for high-precision muon tracking over large areas at high background rates as expected at future high-energy hadron colliders including HL-LHC. The chamber design and construction procedures have been optimized for mass production and provide sense wire positioning accuracy of better than 10 ?m. The rate capability of the sMDT chambers has been extensively tested at the CERN Gamma Irradiation Facility. It exceeds the one of the ATLAS muon drift tube (MDT) chambers, which are operated at unprecedentedly high background rates of neutrons and gamma-rays, by an order of magnitude, which is sufficient for almost the whole muon detector acceptance at FCC-hh at maximum luminosity. sMDT operational and construction experience exists from ATLAS muon spectrometer upgrades which are in progress or under preparation for LHC Phase 1 and 2.

  13. Test results of high-precision large cryogenic lens holders

    Science.gov (United States)

    Gal, C.; Reutlinger, A.; Boesz, A.; Leberle, T.; Mottaghibonab, A.; Eckert, P.; Dubowy, M.; Gebler, H.; Grupp, F.; Geis, N.; Bode, A.; Katterloher, R.; Bender, R.

    2012-09-01

    For the Euclid mission a Pre-Development phase is implemented to prove feasibility of individual components of the system [1]. The Near Infrared Spectrometer and Photometer (NISP) of EUCLID requires high precision large lens holders (?170 mm) at cryogenic temperatures (150K). The four lenses of the optical system are made of different materials: fused silica, CaF2, and LF5G15 that are mounted in a separate lens barrel design. Each lens has its separate mechanical interface to the lens barrel, the so called adaption ring. The performance of the lens holder design is verified by adapted test equipment and test facility including an optical metrology system. The characterization of the lens deformation and displacement (decenter, tilt) due to mechanical loads of the holder itself as well as thermally induced loads are driven by the required submicron precision range and the operational thermal condition. The surface deformation of the lens and its holder is verified by interferometric measurements, while tilt and position accuracy are measured by in-situ fibre based distance sensors. The selected distance measurement sensors have the capability to measure in a few mm range with submicron resolution in ultra high vacuum, in vibration environments and at liquid nitrogen temperatures and below. The calibration of the measurement system is of crucial importance: impacts such as temperature fluctuation, surface roughness, surface reflectivity, straylight effects, etc. on the measured distance are carefully calibrated. Inbuilt thermal expansion effects of the fibre sensors are characterized and proven with lens dummy with quasi zero CTE. The paper presents the test results and measured performance of the high precision large cryogenic lens holders attained by the metrology system. These results are presented on behalf of the EUCLID consortium.

  14. High precision fundamental constants at the TeV scale

    CERN Document Server

    Moch, S; Alekhin, S; Blumlein, J; de la Cruz, L; Dittmaier, S; Dowling, M; Erler, J; Espinosa, J R; Fuster, J; Tormo, X Garcia i; Hoang, A H; Huss, A; Kluth, S; Mulders, M; Papanastasiou, A S; Piclum, J; Rabbertz, K; Schwinn, C; Schulze, M; Shintani, E; Uwer, P; Zerf, N

    2014-01-01

    This report summarizes the proceedings of the 2014 Mainz Institute for Theoretical Physics (MITP) scientific program on "High precision fundamental constants at the TeV scale". The two outstanding parameters in the Standard Model dealt with during the MITP scientific program are the strong coupling constant $\\alpha_s$ and the top-quark mass $m_t$. Lacking knowledge on the value of those fundamental constants is often the limiting factor in the accuracy of theoretical predictions. The current status on $\\alpha_s$ and $m_t$ has been reviewed and directions for future research have been identified.

  15. Globular Cluster Streams as Galactic High-Precision Scales

    CERN Document Server

    Küpper, A H W; Bonaca, A; Johnston, K V; Hogg, D W; Kroupa, P; Santiago, B X

    2015-01-01

    Tidal streams of globular clusters are ideal tracers of the Galactic gravitational potential. Compared to the few known, complex and diffuse dwarf-galaxy streams, they are kinematically cold, have thin morphologies and are abundant in the halo of the Milky Way. Their coldness and thinness in combination with potential epicyclic substructure in the vicinity of the stream progenitor turns them into high-precision scales. With the example of Palomar 5, we demonstrate how modeling of a globular cluster stream allows us to simultaneously measure the properties of the disrupting globular cluster, its orbital motion, and the gravitational potential of the Milky Way.

  16. High precision photon flux determination for photon tagging experiments

    Science.gov (United States)

    Teymurazyan, A.; Ahmidouch, A.; Ambrozewicz, P.; Asratyan, A.; Baker, K.; Benton, L.; Burkert, V.; Clinton, E.; Cole, P.; Collins, P.; Dale, D.; Danagoulian, S.; Davidenko, G.; Demirchyan, R.; Deur, A.; Dolgolenko, A.; Dzyubenko, G.; Ent, R.; Evdokimov, A.; Feng, J.; Gabrielyan, M.; Gan, L.; Gasparian, A.; Glamazdin, A.; Goryachev, V.; Hardy, K.; He, J.; Ito, M.; Jiang, L.; Kashy, D.; Khandaker, M.; Kolarkar, A.; Konchatnyi, M.; Korchin, A.; Korsch, W.; Kosinov, O.; Kowalski, S.; Kubantsev, M.; Kubarovsky, V.; Larin, I.; Lawrence, D.; Li, X.; Martel, P.; Matveev, V.; McNulty, D.; Mecking, B.; Milbrath, B.; Minehart, R.; Miskimen, R.; Mochalov, V.; Nakagawa, I.; Overby, S.; Pasyuk, E.; Payen, M.; Pedroni, R.; Prok, Y.; Ritchie, B.; Salgado, C.; Shahinyan, A.; Sitnikov, A.; Sober, D.; Stepanyan, S.; Stevens, W.; Underwood, J.; Vasiliev, A.; Vishnyakov, V.; Wood, M.; Zhou, S.

    2014-12-01

    The Jefferson Laboratory PrimEx Collaboration has developed and implemented a method to control the tagged photon flux in photoproduction experiments at the 1% level over the photon energy range from 4.9 to 5.5 GeV. This method has been successfully implemented in a high precision measurement of the neutral pion lifetime. Here, we outline the experimental equipment and the analysis techniques used to accomplish this. These include the use of a total absorption counter for absolute flux calibration, a pair spectrometer for online relative flux monitoring, and a new method for post-bremsstrahlung electron counting.

  17. High-precision micro/nano-scale machining system

    Science.gov (United States)

    Kapoor, Shiv G.; Bourne, Keith Allen; DeVor, Richard E.

    2014-08-19

    A high precision micro/nanoscale machining system. A multi-axis movement machine provides relative movement along multiple axes between a workpiece and a tool holder. A cutting tool is disposed on a flexible cantilever held by the tool holder, the tool holder being movable to provide at least two of the axes to set the angle and distance of the cutting tool relative to the workpiece. A feedback control system uses measurement of deflection of the cantilever during cutting to maintain a desired cantilever deflection and hence a desired load on the cutting tool.

  18. High precision spectra at large redshift for dynamical DE cosmologies

    CERN Document Server

    Bonometto, S A; Maccio', A V; Stinson, G

    2010-01-01

    The next generation mass probes will investigate DE nature by measuring non-linear power spectra at various z, and comparing them with high precision simulations. Producing a complete set of them, taking into account baryon physics and for any DE state equation w(z), would really be numerically expensive. Regularities reducing such duty are essential. This paper presents further n-body tests of a relation we found, linking models with DE state parameter w(z) to const.-w models, and also tests the relation in hydro simulations.

  19. High-precision methods in eigenvalue problems and their applications

    CERN Document Server

    Akulenko, Leonid D

    2004-01-01

    This book presents a survey of analytical, asymptotic, numerical, and combined methods of solving eigenvalue problems. It considers the new method of accelerated convergence for solving problems of the Sturm-Liouville type as well as boundary-value problems with boundary conditions of the first, second, and third kind. The authors also present high-precision asymptotic methods for determining eigenvalues and eigenfunctions of higher oscillation modes and consider numerous eigenvalue problems that appear in oscillation theory, acoustics, elasticity, hydrodynamics, geophysics, quantum mechanics, structural mechanics, electrodynamics, and microelectronics.

  20. Precise muon drift tube detectors for high background rate conditions

    CERN Document Server

    Engl, Albert; Dünnweber, Wolfgang

    The muon spectrometer of the ATLAS-experiment at the Large H adron Collider consists of drift tube chambers, which provide the precise m easurement of trajec- tories of traversing muons. In order to determine the moment um of the muons with high precision, the measurement of the position of the m uon in a single tube has to be more accurate than σ ≤ 100 m. The large cross section of proton-proton-collisions and th e high luminosity of the accelerator cause relevant background of neutrons and γ s in the muon spectrome- ter. During the next decade a luminosity upgrade [1] to 5 10 34 cm − 2 s − 1 is planned, which will increase the background counting rates consider ably. In this context this work deals with the further development of the existing drift chamber tech- nology to provide the required accuracy of the position meas urement under high background conditions. Two approaches of improving the dri ft tube chambers are described: • In regions of moderate background rates a faster and more lin ear ...

  1. Repeated High-Precision Gravity and GPS Measurement Techniques

    Science.gov (United States)

    Gettings, P.; Harris, R. N.; Allis, R.; Chapman, D. S.

    2003-12-01

    Repeated high-precision gravity and GPS measurements are becoming a common tool for tracking changes in subsurface reservoirs. Despite this, there is little literature which discusses measurement techniques and the expected errors. Our research has focused on improving measurement techniques to be applied to ground water and geothermal steam reservoirs, including quantifying the minimum error levels with modern equipment. We applied these methods in two studies: ground water monitoring of the southern Salt Lake valley, Utah, USA, and steam monitoring of The Geysers geothermal field, California, USA. Gravity measurements using modern relative high-precision meters, such as Scintrex CG-3Ms or L&R E series, can now be routinely made to an accuracy of 5 μ Gal. Such accuracy requires the use of time series analysis at each station, and non-linear instrument drift functions. Modern computerized meters are capable of internally storing a time series of measurements for each station; older meters can often be fitted to log such data to a field computer. This time series, typically of 10-15 minute duration in our work, can then be analyzed in several ways to produce stable estimates of the gravity reading. In particular, our research has emphasized using a weighted arithmetic average (for long occupations), or a Thiele extrapolation scheme (for shorter station occupations). Instrument drift is removed through a superposition of a linear long-term drift function, and an empirical staircase function formed from differences between repeated station occupations. To achieve high-accuracy GPS measurements while maximizing the number of field stations in a survey, rapid-static measurements are necessary. We have tested the effect of occupation time and processing schemes on the absolute accuracy of the resulting GPS position. Using a post-processing differential method with a fixed (but not necessarily continuous) base station within 15 km, positioning error of <4 cm vertical is

  2. Concentration influences on recovery in a high gradient magnetic separation axial filter

    Energy Technology Data Exchange (ETDEWEB)

    Murariu, V.; Rezlescu, N.; Rotariu, O.; Badescu, V. [Inst. of Technical Physics, Iasi (Romania)

    1998-05-01

    The buildup differential equations for the case of a single wire in high gradient magnetic filtration (HGMF)-axial configuration taking into account the suspension concentration are solved. A new equation for the deposit contour surface at different moments and for different suspension concentrations are obtained. The existence of a particulate suspension concentration, for which the radial extension velocity of deposit is maximum, is evidenced. The recovery for an ordered ferromagnetic matrix is calculated. The influence of the solid particle concentration from suspension on the filtration efficiency is presented.

  3. New machining method of high precision infrared window part

    Science.gov (United States)

    Yang, Haicheng; Su, Ying; Xu, Zengqi; Guo, Rui; Li, Wenting; Zhang, Feng; Liu, Xuanmin

    2016-10-01

    Most of the spherical shell of the photoelectric multifunctional instrument was designed as multi optical channel mode to adapt to the different band of the sensor, there were mainly TV, laser and infrared channels. Without affecting the optical diameter, wind resistance and pneumatic performance of the optical system, the overall layout of the spherical shell was optimized to save space and reduce weight. Most of the shape of the optical windows were special-shaped, each optical window directly participated in the high resolution imaging of the corresponding sensor system, and the optical axis parallelism of each sensor needed to meet the accuracy requirement of 0.05mrad.Therefore precision machining of optical window parts quality will directly affect the photoelectric system's pointing accuracy and interchangeability. Processing and testing of the TV and laser window had been very mature, while because of the special nature of the material, transparent and high refractive rate, infrared window parts had the problems of imaging quality and the control of the minimum focal length and second level parallel in the processing. Based on years of practical experience, this paper was focused on how to control the shape and parallel difference precision of infrared window parts in the processing. Single pass rate was increased from 40% to more than 95%, the processing efficiency was significantly enhanced, an effective solution to the bottleneck problem in the actual processing, which effectively solve the bottlenecks in research and production.

  4. High Precision Signal Processing Algorithm for White Light Interferometry

    Directory of Open Access Journals (Sweden)

    Jeonggon Harrison Kim

    2008-12-01

    Full Text Available A new signal processing algorithm for absolute temperature measurement using white light interferometry has been proposed and investigated theoretically. The proposed algorithm determines the phase delay of an interferometer with very high precision (<< one fringe by identifying the zero order fringe peak of cross-correlation of two fringe scans of white light interferometer. The algorithm features cross-correlation of interferometer fringe scans, hypothesis testing and fine tuning. The hypothesis test looks for a zero order fringe peak candidate about which the cross-correlation is symmetric minimizing the uncertainty of mis-identification. Fine tuning provides the proposed algorithm with high precision subsample resolution phase delay estimation capability. The shot noise limited performance of the proposed algorithm has been analyzed using computer simulations. Root-mean-square (RMS phase error of the estimated zero order fringe peak has been calculated for the changes of three different parameters (SNR, fringe scan sample rate, coherence length of light source. Computer simulations showed that the proposed signal processing algorithm identified the zero order fringe peak with a miss rate of 3 x 10-4 at 31 dB SNR and the extrapolated miss rate at 35 dB was 3 x 10-8. Also, at 35 dB SNR, RMS phase error less than 10-3 fringe was obtained. The proposed signal processing algorithm uses a software approach that is potentially inexpensive, simple and fast.

  5. Dynamics of High-Speed Precision Geared Rotor Systems

    Directory of Open Access Journals (Sweden)

    Lim Teik C.

    2014-07-01

    Full Text Available Gears are one of the most widely applied precision machine elements in power transmission systems employed in automotive, aerospace, marine, rail and industrial applications because of their reliability, precision, efficiency and versatility. Fundamentally, gears provide a very practical mechanism to transmit motion and mechanical power between two rotating shafts. However, their performance and accuracy are often hampered by tooth failure, vibrations and whine noise. This is most acute in high-speed, high power density geared rotor systems, which is the primary scope of this paper. The present study focuses on the development of a gear pair mathematical model for use to analyze the dynamics of power transmission systems. The theory includes the gear mesh representation derived from results of the quasi-static tooth contact analysis. This proposed gear mesh theory comprising of transmission error, mesh point, mesh stiffness and line-of-action nonlinear, time-varying parameters can be easily incorporated into a variety of transmission system models ranging from the lumped parameter type to detailed finite element representation. The gear dynamic analysis performed led to the discovery of the out-of-phase gear pair torsion modes that are responsible for much of the mechanical problems seen in gearing applications. The paper concludes with a discussion on effectual design approaches to minimize the influence of gear dynamics and to mitigate gear failure in practical power transmission systems.

  6. MultiView High Precision VLBI Astrometry at Low Frequencies

    Science.gov (United States)

    Rioja, María J.; Dodson, Richard; Orosz, Gabor; Imai, Hiroshi; Frey, Sandor

    2017-03-01

    The arrival of the Square Kilometer Array (SKA) will revitalize all aspects of Very Long Baseline Interferometry (VLBI) astronomy at lower frequencies. In the last decade, there have been huge strides toward routinely achieving high precision VLBI astrometry at frequencies dominated by tropospheric contributions, most notably at 22 GHz, using advanced phase-referencing techniques. Nevertheless, to increase the capability for high precision astrometric measurements at low radio frequencies (phase-referencing calibrator. The MultiView technique holds the key to compensating for atmospheric spatial-structure errors, by using observations of multiple calibrators and two-dimensional interpolation in the visibility domain. In this paper we present the first demonstration of the power of MultiView using three calibrators, several degrees from the target, along with a comparative study of the astrometric accuracy between MultiView and phase-referencing techniques. MultiView calibration provides an order of magnitude improvement in astrometry with respect to conventional phase referencing, achieving ∼100 μas astrometry errors in a single epoch of observations, effectively reaching the thermal noise limit. MultiView will achieve its full potential with the enhanced sensitivity and multibeam capabilities of SKA and the pathfinders, which will enable simultaneous observations of the target and calibrators. Our demonstration indicates that the 10 μas goal of astrometry at ∼1.6 GHz using VLBI with SKA is feasible using the MultiView technique.

  7. On the performance of circular concrete-filled high strength steel columns under axial loading

    Directory of Open Access Journals (Sweden)

    Mohamed Mahmoud El-Heweity

    2012-06-01

    Full Text Available This work presents a numerical study to investigate the performance of circular high-strength steel tubes filled with concrete (CFT under monotonic axial loading. A model is developed to implement the material constitutive relationships and non-linearity. Calibration against previous experimental data shows good agreement. A parametric study is then conducted using the model and compared with codes provisions. Strength and ductility of confined concrete are of primary concern. Variables considered are yield stress of steel tube and column diameter. The assessment of column performance is based on axial load carrying capacities and enhancements of both strength and ductility due to confinement. Two parameters namely strength enhancement factor (Kf and ductility index (μ are clearly defined and introduced for assessment. Results indicate that both concrete strength and ductility of CFT columns are enhanced but to different extents. The ductile behaviors are significantly evident. The increase in yield stress of steel tube has a minimal effect on concrete strength but pronounced effect on concrete ductility. However, reduction in ductility is associated with using high-tensile steel of Grade 70. The overall findings indicate that the use of high-strength tube in CFT columns is not promising. This finding may seriously be considered in seismic design.

  8. The development of high precision carbon fiber composite mirror

    Science.gov (United States)

    Xu, Liang; Ding, Jiao-teng; Wang, Yong-jie; Xie, Yong-jie; Ma, Zhen; Fan, Xue-wu

    2016-10-01

    Due to low density, high stiffness, low thermal expansion coefficient, duplicate molding, etc., carbon fiber reinforced polymer (CFRP) is one of the potential materials of the optical mirror. The process developed for Φ300mm high precision CFRP mirror described in this paper. A placement tool used to improve laying accuracy up to ± 0.1°.A special reinforced cell structure designed to increase rigidity and thermal stability. Optical replication process adopted for surface modification of the carbon fiber composite mirror blank. Finally, surface accuracy RMS of Φ300mm CFRP mirror is 0.22μm, surface roughness Ra is about 2nm, and the thermal stability can achieve 13nm /°C from the test result. The research content is of some reference value in the infrared as well as visible light applications.

  9. A detector interferometric calibration experiment for high precision astrometry

    CERN Document Server

    Crouzier, A; Henault, F; Leger, A; Cara, C; LeDuigou, J M; Preis, O; Kern, P; Delboulbe, A; Martin, G; Feautrier, P; Stadler, E; Lafrasse, S; Rochat, S; Ketchazo, C; Donati, M; Doumayrou, E; Lagage, P O; Shao, M; Goullioud, R; Nemati, B; Zhai, C; Behar, E; Potin, S; Saint-Pe, M; Dupont, J

    2016-01-01

    Context: Exoplanet science has made staggering progress in the last two decades, due to the relentless exploration of new detection methods and refinement of existing ones. Yet astrometry offers a unique and untapped potential of discovery of habitable-zone low-mass planets around all the solar-like stars of the solar neighborhood. To fulfill this goal, astrometry must be paired with high precision calibration of the detector. Aims: We present a way to calibrate a detector for high accuracy astrometry. An experimental testbed combining an astrometric simulator and an interferometric calibration system is used to validate both the hardware needed for the calibration and the signal processing methods. The objective is an accuracy of 5e-6 pixel on the location of a Nyquist sampled polychromatic point spread function. Methods: The interferometric calibration system produced modulated Young fringes on the detector. The Young fringes were parametrized as products of time and space dependent functions, based on vari...

  10. Design and High Precision Monitoring of Detector Structures at CERN

    CERN Document Server

    Lackner, Friedrich; Riegler, Werner

    2007-01-01

    Situated on the outskirts of Geneva, CERN is the leading center for particle physics in the world. The Large Hadron Collider (LHC) with its 27 km ringshaped accelerator, which is currently under construction and will be operational in 2008, will begin a new era in high energy physics by revealing the basic constituents of the universe. One of the experiments is ALICE (A Large Ion - Colliding - Experiment), a detector consisting of multiple layers of sub detectors around the collision point to detect dierent types and properties of particles created in the collisions. Those particles are identified via their energy, momentum, track and decay products, and it is therefore important to align the various sub detectors very precisely to each other and monitor their position. The monitoring systems have to operate for an extended period of time under extreme conditions (e.g. high radiation) and must not absorb too many of the particles created in the collisions. This dissertation describes monitoring systems develo...

  11. The QCD coupling and parton distributions at high precision

    Energy Technology Data Exchange (ETDEWEB)

    Bluemlein, Johannes

    2010-07-15

    A survey is given on the present status of the nucleon parton distributions and related precision calculations and precision measurements of the strong coupling constant {alpha}{sub s}(M{sup 2}{sub Z}). We also discuss the impact of these quantities on precision observables at hadron colliders. (orig.)

  12. High precision measurement of electrical resistance across endothelial cell monolayers.

    Science.gov (United States)

    Tschugguel, W; Zhegu, Z; Gajdzik, L; Maier, M; Binder, B R; Graf, J

    1995-05-01

    Effects of vasoactive agonists on endothelial permeability was assessed by measurement of transendothelial electrical resistance (TEER) of human umbilical vein endothelial cells (HUVECs) grown on porous polycarbonate supports. Because of the low values of TEER obtained in this preparation (< 5 omega cm2) a design of an Ussing type recording chamber was chosen that provided for a homogeneous electric field across the monolayer and for proper correction of series resistances. Precision current pulses and appropriate rates of sampling and averaging of the voltage signal allowed for measurement of < 0.1 omega resistance changes of the endothelium on top of a 21 omega series resistance of the support and bathing fluid layers. Histamine (10 microM) and thrombin (10 U/ml) induced an abrupt and substantial decrease of TEER, bradykinin (1 microM) was less effective, PAF (380 nM) and LTC4 (1 microM) had no effect. TEER was also reduced by the calcium ionophore A-23187 (10 microM). The technique allows for measurements of TEER in low resistance monolayer cultures with high precision and time resolution. The results obtained extend previous observations in providing quantitative data on the increase of permeability of HUVECs in response to vasoactive agonists.

  13. HIGH PRECISION ROVIBRATIONAL SPECTROSCOPY OF OH{sup +}

    Energy Technology Data Exchange (ETDEWEB)

    Markus, Charles R.; Hodges, James N.; Perry, Adam J.; Kocheril, G. Stephen; McCall, Benjamin J. [Department of Chemistry, University of Illinois, Urbana, IL 61801 (United States); Müller, Holger S. P., E-mail: bjmccall@illinois.edu [I. Physikalisches Institut, Universität zu Köln, Zülpicher Str. 77, D-50937 Köln (Germany)

    2016-02-01

    The molecular ion OH{sup +} has long been known to be an important component of the interstellar medium. Its relative abundance can be used to indirectly measure cosmic ray ionization rates of hydrogen, and it is the first intermediate in the interstellar formation of water. To date, only a limited number of pure rotational transitions have been observed in the laboratory making it necessary to indirectly calculate rotational levels from high-precision rovibrational spectroscopy. We have remeasured 30 transitions in the fundamental band with MHz-level precision, in order to enable the prediction of a THz spectrum of OH{sup +}. The ions were produced in a water cooled discharge of O{sub 2}, H{sub 2}, and He, and the rovibrational transitions were measured with the technique Noise Immune Cavity Enhanced Optical Heterodyne Velocity Modulation Spectroscopy. These values have been included in a global fit of field free data to a {sup 3}Σ{sup −} linear molecule effective Hamiltonian to determine improved spectroscopic parameters which were used to predict the pure rotational transition frequencies.

  14. Low-pressure reversible axial fan with straight profile blades and relatively high efficiency

    Directory of Open Access Journals (Sweden)

    Spasić Živan T.

    2012-01-01

    Full Text Available The paper presents the design and operating characteristics of a model of reversible axial fan with only one impeller, whose reversibility is achieved by changing the direction of rotation. The fan is designed for the purpose of providing alternating air circulation in wood dryers in order to reduce the consumption of electricity for the fan and increase energy efficiency of the entire dryer. To satisfy the reversibility of flow, the shape of the blade profile is symmetrical along the longitudinal and transversal axes of the profile. The fan is designed with equal specific work of all elementary stages, using the method of lift forces. The impeller blades have straight mean line profiles. The shape of the blade profile was adopted after the numerical simulations were carried out and high efficiency was achieved. Based on the calculation and conducted numerical simulations, a physical model of the fan was created and tested on a standard test rig, with air loading at the suction side of the fan. The operating characteristics are shown for different blade angles. The obtained maximum efficiency was around 0.65, which represents a rather high value for axial fans with straight profile blades.

  15. Precision Viticulture from Multitemporal, Multispectral Very High Resolution Satellite Data

    Science.gov (United States)

    Kandylakis, Z.; Karantzalos, K.

    2016-06-01

    In order to exploit efficiently very high resolution satellite multispectral data for precision agriculture applications, validated methodologies should be established which link the observed reflectance spectra with certain crop/plant/fruit biophysical and biochemical quality parameters. To this end, based on concurrent satellite and field campaigns during the veraison period, satellite and in-situ data were collected, along with several grape samples, at specific locations during the harvesting period. These data were collected for a period of three years in two viticultural areas in Northern Greece. After the required data pre-processing, canopy reflectance observations, through the combination of several vegetation indices were correlated with the quantitative results from the grape/must analysis of grape sampling. Results appear quite promising, indicating that certain key quality parameters (like brix levels, total phenolic content, brix to total acidity, anthocyanin levels) which describe the oenological potential, phenolic composition and chromatic characteristics can be efficiently estimated from the satellite data.

  16. A high-precision control system for robotic welding positioner

    Institute of Scientific and Technical Information of China (English)

    Shi Yu; Fan Ding; Chen Jianhong

    2005-01-01

    Aiming at the robotic welding positioner with characteristic of parameter change, load change, nonlinearity, and an intelligent control system was researched and developed. This control system used a two-mode controller that based on Fuzzy and PID control method. The results of simulation show that the dynamic and steady performances of the intelligent controller are better than that of single PID or Fuzzy controller. This paper has made a detail theoretical analysis of the constitution design and real-time controlled software and brought up the design and fulfillment method of multi-task real-time control software of high precisely and numerically controlled welding positioner , which has a good result in practice.

  17. Suppression of radiation damping for high precision quantitative NMR.

    Science.gov (United States)

    Bayle, Kevin; Julien, Maxime; Remaud, Gérald S; Akoka, Serge

    2015-10-01

    True quantitative analysis of concentrated samples by (1)H NMR is made very difficult by Radiation Damping. A novel NMR sequence (inspired by the WET NMR sequence and by Outer Volume Saturation methods) is therefore proposed to suppress this phenomenon by reducing the spatial area and consequently the number of spins contributing to the signal detected. The size of the detected volume can be easily chosen in a large range and line shape distortions are avoided thanks to a uniform signal suppression of the outer volume. Composition of a mixture can as a result be determined with very high accuracy (precision and trueness) at the per mille level whatever the concentrations and without hardware modification.

  18. Monolithic interferometer for high precision radial velocity measurements

    Science.gov (United States)

    Wan, Xiaoke; Ge, Jian; Wang, Ji; Lee, Brian

    2009-08-01

    In high precision radial velocity (RV) measurements for extrasolar planets searching and studies, a stable wide field Michelson interferometer is very critical in Exoplanet Tracker (ET) instruments. Adopting a new design, monolithic interferometers are homogenous and continuous in thermal expansion, and field compensation and thermal compensation are both satisfied. Interferometer design and fabrication are decrypted in details. In performance evaluations, field angle is typically 22° and thermal sensitivity is typically -1.7 x 10-6/°C, which corresponds to ~500 m/s /°C in RV scale. In interferometer stability monitoring using a wavelength stabilized laser source, phase shift data was continuously recorded for nearly seven days. Appling a frequent calibration every 30 minutes as in typical star observations, the interferometer instability contributes less than 1.4 m/s in RV error, in a conservative estimation.

  19. A detector interferometric calibration experiment for high precision astrometry

    Science.gov (United States)

    Crouzier, A.; Malbet, F.; Henault, F.; Léger, A.; Cara, C.; LeDuigou, J. M.; Preis, O.; Kern, P.; Delboulbe, A.; Martin, G.; Feautrier, P.; Stadler, E.; Lafrasse, S.; Rochat, S.; Ketchazo, C.; Donati, M.; Doumayrou, E.; Lagage, P. O.; Shao, M.; Goullioud, R.; Nemati, B.; Zhai, C.; Behar, E.; Potin, S.; Saint-Pe, M.; Dupont, J.

    2016-11-01

    Context. Exoplanet science has made staggering progress in the last two decades, due to the relentless exploration of new detection methods and refinement of existing ones. Yet astrometry offers a unique and untapped potential of discovery of habitable-zone low-mass planets around all the solar-like stars of the solar neighborhood. To fulfill this goal, astrometry must be paired with high precision calibration of the detector. Aims: We present a way to calibrate a detector for high accuracy astrometry. An experimental testbed combining an astrometric simulator and an interferometric calibration system is used to validate both the hardware needed for the calibration and the signal processing methods. The objective is an accuracy of 5 × 10-6 pixel on the location of a Nyquist sampled polychromatic point spread function. Methods: The interferometric calibration system produced modulated Young fringes on the detector. The Young fringes were parametrized as products of time and space dependent functions, based on various pixel parameters. The minimization of function parameters was done iteratively, until convergence was obtained, revealing the pixel information needed for the calibration of astrometric measurements. Results: The calibration system yielded the pixel positions to an accuracy estimated at 4 × 10-4 pixel. After including the pixel position information, an astrometric accuracy of 6 × 10-5 pixel was obtained, for a PSF motion over more than five pixels. In the static mode (small jitter motion of less than 1 × 10-3 pixel), a photon noise limited precision of 3 × 10-5 pixel was reached.

  20. Precision muon tracking detectors for high-energy hadron colliders

    Science.gov (United States)

    Gadow, Ph.; Kortner, O.; Kroha, H.; Richter, R.

    2017-02-01

    Small-diameter muon drift tube (sMDT) chambers with 15 mm tube diameter are a cost-effective technology for high-precision muon tracking over large areas at high background rates as expected at future high-energy hadron colliders including HL-LHC. The chamber design and construction procedures have been optimised for mass production and provide sense wire positioning accuracy of better than 10 μm. The rate capability of the sMDT chambers has been extensively tested at the CERN Gamma Irradiation Facility. It exceeds the one of the ATLAS muon drift tube (MDT) chambers, which are operated at unprecedentedly high background rates of neutrons and γ-rays, by an order of magnitude, which is sufficient for almost the whole of the muon detector acceptance at FCC-hh at maximum luminosity. sMDT operational and construction experience exists from ATLAS muon spectrometer upgrades which are in progress or under preparation for LHC Phase 1 and 2.

  1. Fast, High-Precision Readout Circuit for Detector Arrays

    Science.gov (United States)

    Rider, David M.; Hancock, Bruce R.; Key, Richard W.; Cunningham, Thomas J.; Wrigley, Chris J.; Seshadri, Suresh; Sander, Stanley P.; Blavier, Jean-Francois L.

    2013-01-01

    The GEO-CAPE mission described in NASA's Earth Science and Applications Decadal Survey requires high spatial, temporal, and spectral resolution measurements to monitor and characterize the rapidly changing chemistry of the troposphere over North and South Americas. High-frame-rate focal plane arrays (FPAs) with many pixels are needed to enable such measurements. A high-throughput digital detector readout integrated circuit (ROIC) that meets the GEO-CAPE FPA needs has been developed, fabricated, and tested. The ROIC is based on an innovative charge integrating, fast, high-precision analog-to-digital circuit that is built into each pixel. The 128×128-pixel ROIC digitizes all 16,384 pixels simultaneously at frame rates up to 16 kHz to provide a completely digital output on a single integrated circuit at an unprecedented rate of 262 million pixels per second. The approach eliminates the need for off focal plane electronics, greatly reducing volume, mass, and power compared to conventional FPA implementations. A focal plane based on this ROIC will require less than 2 W of power on a 1×1-cm integrated circuit. The ROIC is fabricated of silicon using CMOS technology. It is designed to be indium bump bonded to a variety of detector materials including silicon PIN diodes, indium antimonide (InSb), indium gallium arsenide (In- GaAs), and mercury cadmium telluride (HgCdTe) detector arrays to provide coverage over a broad spectral range in the infrared, visible, and ultraviolet spectral ranges.

  2. High-rate axial-field ionization chamber for particle identification of Radioactive beams

    Science.gov (United States)

    Desouza, Romualdo; Vadas, Justin; Singh, Varinderjit; Visser, G.; Alexander, A.; Hudan, S.; Huston, J.; Wiggins, B.; Chbihi, A.; Famiano, M.; Bischak, M.

    2017-01-01

    The design, construction and performance characteristics of a simple axial-field ionization chamber suitable for identifying ions in a radioactive beam are presented. The detector is optimized for use with low-energy radioactive beams (<) 5 MeV/A. A fast charge sensitive amplifier (CSA) integrated into the detector design is also described. Coupling this fast CSA to the axial field ionization chamber produces an output pulse with a rise-time of 60 to 70 ns and a fall time of 100 ns, making the detector capable of sustaining a relatively high rate while providing a time resolution of 6 to 8 ns. Tests with an α source establish the detector energy resolution as 8 % for an energy deposit of 3.5 MeV. Beam tests indicate that the detector is an effective tool for the characterization of low-energy radioactive beams at beam intensities up to 3 x 105 ions/s. Supported by the U.S. DOE under Award # DE-FG02-88ER-40404 and the NSF under Grant No. 1342962.

  3. High-rate axial-field ionization chamber for particle identification of radioactive beams

    CERN Document Server

    Vadas, J; Visser, G; Alexander, A; Hudan, S; Huston, J; Wiggins, B B; Chbihi, A; Famiano, M; Bischak, M M; deSouza, R T

    2016-01-01

    The design, construction and performance characteristics of a simple axial-field ionization chamber suitable for identifying ions in a radioactive beam are presented. Optimized for use with low-energy radioactive beams (< 5 MeV/A) the detector presents only three 0.5 $\\mu$m/cm$^2$ foils to the beam in addition to the detector gas. A fast charge sensitive amplifier (CSA) integrated into the detector design is also described. Coupling this fast CSA to the axial field ionization chamber produces an output pulse with a risetime of 60-70 ns and a fall time of 100 ns, making the detector capable of sustaining a relatively high rate. Tests with an $\\alpha$ source establish the detector energy resolution as $\\sim$8 $\\%$ for an energy deposit of $\\sim$3.5 MeV. The energy resolution with beams of 2.5 and 4.0 MeV/A $^{39}$K ions and the dependence of the energy resolution on beam intensity is measured. At an instantaneous rate of 3 x 10$^5$ ions/s the energy resolution has degraded to 14% with a pileup of 12%. The go...

  4. Characterization and simulation studies on high tilt ion implantation for precision halo implant applications

    Energy Technology Data Exchange (ETDEWEB)

    Guo, B.N. [Varian Semiconductor Equipment Associates, Inc., 35 Dory Road, Gloucester, MA 01930 (United States)]. E-mail: baonian.guo@vsea.com; Zhao, Z.Y. [Spansion LLC, 5204 E. Ben White Blvd., Austin, TX 78741 (United States); Falk, S. [Varian Semiconductor Equipment Associates, Inc., 35 Dory Road, Gloucester, MA 01930 (United States); Liu, J. [Varian Semiconductor Equipment Associates, Inc., 35 Dory Road, Gloucester, MA 01930 (United States); Shim, K.H. [Varian Semiconductor Equipment Associates, Inc., 35 Dory Road, Gloucester, MA 01930 (United States); Jeong, U. [Varian Semiconductor Equipment Associates, Inc., 35 Dory Road, Gloucester, MA 01930 (United States); Mehta, S. [Varian Semiconductor Equipment Associates, Inc., 35 Dory Road, Gloucester, MA 01930 (United States)

    2007-08-15

    Precision dopant placement at high tilt angles for halo applications is required in the fabrication of advanced devices to achieve better transistor characteristics, such as suppression of short channel effects, V {sub t} control and drive current. However, monitoring high tilt implants is not popular in semiconductor fabs, even though most have started monitoring zero-tilt implants in the recent couple of years. In this paper, the authors explore the possibilities of using high tilt angles with higher Miller Index channels. As an example, axial channeling along the <1 1 2> direction is used to evaluate the angle control performance of the VIISta 810EHP medium current ion implanter. Crystal-TRIM (a Monte Carlo simulation code) calculations are compared with experimental SIMS (Secondary Ion Mass Spectrometry) profiles. In addition, the effects of wafer orientation on the platen and wafer mis-cut on the dopant profiles are discussed. Metrology characterization, such as ThermaWave{sup TM} and SIMS, of the <1 1 2> ion channeling is presented.

  5. High precision ultrasonic guided wave technique for inspection of power transmission line

    Science.gov (United States)

    Cheng, Jun; Qiu, Jinhao; Ji, Hongli; Wang, Enrong; Takagi, Toshiyuki; Uchimoto, Tetsuya

    2017-01-01

    Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave propagation in this structure is very complicated, leading to the unfavorable defect localization accuracy. Aiming at this situation, a high precision UGW technique for inspection of local surface defect in power transmission line is proposed. The technique is realized by adopting a novel segmental piezoelectric ring transducer and transducer mounting scheme, combining with the comprehensive characterization of wave propagation and circumferential defect positioning with multiple piezoelectric elements. Firstly, the propagation path of guided waves in the multi-wires of transmission line under the proposed technique condition is investigated experimentally. Next, the wave velocities are calculated by dispersion curves and experiment test respectively, and from comparing of the two results, the guided wave mode propagated in transmission line is confirmed to be F(1,1) mode. Finally, the axial and circumferential positioning of local defective wires in transmission line are both achieved, by using multiple piezoelectric elements to surround the stands and send elastic waves into every single wire. The proposed research can play a role of guiding the development of highly effective UGW method and detecting system for multi-wire transmission line.

  6. High-precision experiments on a single trapped radium ion

    Energy Technology Data Exchange (ETDEWEB)

    Boell, O.; Giri, G.S.; Jungmann, K.; Sahoo, B.K.; Timmermans, R.G.E.; Versolato, O.O.; Wansbeek, L.W.; Willmann, L. [KVI, University of Groningen (Netherlands)

    2009-07-01

    A single, trapped radium ion is an ideal candidate for high precision experiments. Two Ra{sup +} experiments are under construction at KVI. Ultra-narrow transitions in radium ions provide an excellent basis for an all-optical, high-stability frequency standard, i.e. a clock. The off-the-shelf availability of semiconductor lasers for all necessary transitions is highly advantageous. In certain odd isotopes of radium, the nuclear electric quadrupole shift is absent. The same system and experimental hardware will be used to search for physics beyond the Standard Model of particle physics by measuring Atomic Parity Violation. This will serve as a low-energy test of the running of the electroweak mixing angle. Recent calculations have shown Ra{sup +} to be the superior candidate. Recently we have succeeded in the production and efficient slowing down of isotopes around {sup 213}Ra at the AGOR cyclotron and the TRI{mu}P facility of KVI. Progress has been made in the development of ion traps and in the laser set-up in a dedicated laser laboratory. Laser spectroscopy of the radium ion and the first ever trapping of this particle are planned in the near future.

  7. Developing Performance Estimates for High Precision Astrometry with TMT

    Science.gov (United States)

    Schoeck, Matthias; Do, Tuan; Ellerbroek, Brent; Herriot, Glen; Meyer, Leo; Suzuki, Ryuji; Wang, Lianqi; Yelda, Sylvana

    2013-12-01

    Adaptive optics on Extremely Large Telescopes will open up many new science cases or expand existing science into regimes unattainable with the current generation of telescopes. One example of this is high-precision astrometry, which has requirements in the range from 10 to 50 micro-arc-seconds for some instruments and science cases. Achieving these requirements imposes stringent constraints on the design of the entire observatory, but also on the calibration procedures, observing sequences and the data analysis techniques. This paper summarizes our efforts to develop a top down astrometry error budget for TMT. It is predominantly developed for the first-light AO system, NFIRAOS, and the IRIS instrument, but many terms are applicable to other configurations as well. Astrometry error sources are divided into 5 categories: Reference source and catalog errors, atmospheric refraction correction errors, other residual atmospheric effects, opto-mechanical errors and focal plane measurement errors. Results are developed in parametric form whenever possible. However, almost every error term in the error budget depends on the details of the astrometry observations, such as whether absolute or differential astrometry is the goal, whether one observes a sparse or crowded field, what the time scales of interest are, etc. Thus, it is not possible to develop a single error budget that applies to all science cases and separate budgets are developed and detailed for key astrometric observations. Our error budget is consistent with the requirements for differential astrometry of tens of micro-arc-seconds for certain science cases. While no show stoppers have been found, the work has resulted in several modifications to the NFIRAOS optical surface specifications and reference source design that will help improve the achievable astrometry precision even further.

  8. Evaluation of High-Precision Sensors in Structural Monitoring

    Directory of Open Access Journals (Sweden)

    Bihter Erol

    2010-12-01

    Full Text Available One of the most intricate branches of metrology involves the monitoring of displacements and deformations of natural and anthropogenic structures under environmental forces, such as tidal or tectonic phenomena, or ground water level changes. Technological progress has changed the measurement process, and steadily increasing accuracy requirements have led to the continued development of new measuring instruments. The adoption of an appropriate measurement strategy, with proper instruments suited for the characteristics of the observed structure and its environmental conditions, is of high priority in the planning of deformation monitoring processes. This paper describes the use of precise digital inclination sensors in continuous monitoring of structural deformations. The topic is treated from two viewpoints: (i evaluation of the performance of inclination sensors by comparing them to static and continuous GPS observations in deformation monitoring and (ii providing a strategy for analyzing the structural deformations. The movements of two case study objects, a tall building and a geodetic monument in Istanbul, were separately monitored using dual-axes micro-radian precision inclination sensors (inclinometers and GPS. The time series of continuous deformation observations were analyzed using the Least Squares Spectral Analysis Technique (LSSA. Overall, the inclinometers showed good performance for continuous monitoring of structural displacements, even at the sub-millimeter level. Static GPS observations remained insufficient for resolving the deformations to the sub-centimeter level due to the errors that affect GPS signals. With the accuracy advantage of inclination sensors, their use with GPS provides more detailed investigation of deformation phenomena. Using inclinometers and GPS is helpful to be able to identify the components of structural responses to the natural forces as static, quasi-static, or resonant.

  9. High-resolution AUV mapping and lava flow ages at Axial Seamount

    Science.gov (United States)

    Clague, D. A.; Paduan, J. B.; Dreyer, B. M.; Caress, D. W.; Martin, J.

    2011-12-01

    Mapping along mid-ocean ridges, as on land, requires identification of flow boundaries and sequence, and ages of some flows to understand eruption history. Multibeam sonars on autonomous underwater vehicles (AUV) now generate 1-m resolution maps that resolve lava pillars, internal flow structures and boundaries, and lava flow emplacement sequences using crosscutting relations and abundance of fissures. MBARI has now mapped the summit caldera floor and rims and the upper south rift zone on Axial Seamount on the Juan de Fuca Ridge. With the advent of the high-resolution bathymetry and the ability to observe flow contacts to determine superposition using ROVs and submersibles, the missing component has been determining absolute ages of the flows. We used the MBARI ROV Doc Ricketts to collect short push cores (<30 cm) of the thin sediment nestled between pillow lava lobes and sieve and then hand-pick planktic foraminifera from the base of the cores to date by AMS 14C. Ages of planktic foraminifera are marine-calibrated in years before present, and provide minimum ages for the underlying flows, as there is probably some basal sediment that is not recovered. 14C ages have been determined for 10 cores near the summit of Axial Seamount and for 6 from the lowermost south rift. Ages of nearby samples commonly yield statistically identical ages, and 2 cores near the center of the caldera had multiple layers dated. These ages systematically increase with depth, indicating that redistribution of sediment by bottom currents does not significantly affect the stratigraphy. We will expand these collections in summer 2011. The coring is accompanied by collection of flow samples for chemistry and video observations to confirm contact locations and flow superposition inferred from the mapping data. Six ages from the lowermost part of the south rift of Axial Seamount include samples on a cone with deep summit crater that is ~16,580 aBP and on 5 flows between 950 and 1510 aBP. Two

  10. Silicon Avalanche Pixel Sensor for High Precision Tracking

    CERN Document Server

    D'Ascenzo, N; Moon, C S; Morsani, F; Ratti, L; Saveliev, V; Navarro, A Savoy; Xie, Q

    2013-01-01

    The development of an innovative position sensitive pixelated sensor to detect and measure with high precision the coordinates of the ionizing particles is proposed. The silicon avalanche pixel sensors (APiX) is based on the vertical integration of avalanche pixels connected in pairs and operated in coincidence in fully digital mode and with the processing electronics embedded on the chip. The APiX sensor addresses the need to minimize the material budget and related multiple scattering effects in tracking systems requiring a high spatial resolution in the presence of a large occupancy. The expected operation of the new sensor features: low noise, low power consumption and suitable radiation tolerance. The APiX device provides on-chip digital information on the position of the coordinate of the impinging charged particle and can be seen as the building block of a modular system of pixelated arrays, implementing a sparsified readout. The technological challenges are the 3D integration of the device under CMOS ...

  11. High precision analysis of the solar twin HIP 100963

    CERN Document Server

    Galarza, Jhon Yana; Ramírez, Ivan; Karakas, Amanda I; Asplund, Martin; Liu, Fan

    2016-01-01

    Methods. We used the HIRES spectrograph on the Keck I Telescope to acquire high resolution (R $\\approx$ 70000) and high-signal-to-noise ratio spectra (S/N $\\approx$ 400 - 650 per pixel) of HIP 100963 and the Sun, for a differential abundance analysis. We measured the equivalent widths (EWs) of iron lines to determine the stellar parameters employing the differential spectroscopic equilibrium. We determine through a differential abundance analysis with respect to the Sun, the composition of volatile, refractory and neutron-capture elements. Results. The stellar parameters that we found are: $T_{\\rm{eff}}=5818 \\pm 4$ K, log $g = 4.49 \\pm 0.01$ dex, $v_{t} = 1.03 \\pm 0.01 $ $\\rm{km\\ {s}}^{-1}$ and [Fe/H] $ = -\\ 0.003 \\pm 0.004$ dex. These low errors allow us to compute a precise mass ($1.03^{+0.02}_{-0.01}$ \\sm) and age (2.0 $\\pm$ 0.4 Gyr), obtained using Yonsei-Yale isochrones. Using our [Y/Mg] ratio, we have determined an age of $2.1 \\pm 0.4$ Gyr, in agreement with the age computed using isochrones. Our isochr...

  12. A Computer Controlled Precision High Pressure Measuring System

    Science.gov (United States)

    Sadana, S.; Yadav, S.; Jha, N.; Gupta, V. K.; Agarwal, R.; Bandyopadhyay, A. K.; Saxena, T. K.

    2011-01-01

    A microcontroller (AT89C51) based electronics has been designed and developed for high precision calibrator based on Digiquartz pressure transducer (DQPT) for the measurement of high hydrostatic pressure up to 275 MPa. The input signal from DQPT is converted into a square wave form and multiplied through frequency multiplier circuit over 10 times to input frequency. This input frequency is multiplied by a factor of ten using phased lock loop. Octal buffer is used to store the calculated frequency, which in turn is fed to microcontroller AT89C51 interfaced with a liquid crystal display for the display of frequency as well as corresponding pressure in user friendly units. The electronics developed is interfaced with a computer using RS232 for automatic data acquisition, computation and storage. The data is acquired by programming in Visual Basic 6.0. This system is interfaced with the PC to make it a computer controlled system. The system is capable of measuring the frequency up to 4 MHz with a resolution of 0.01 Hz and the pressure up to 275 MPa with a resolution of 0.001 MPa within measurement uncertainty of 0.025%. The details on the hardware of the pressure measuring system, associated electronics, software and calibration are discussed in this paper.

  13. High-precision heliostat for long-path light tracking

    Science.gov (United States)

    Hawat, Tom; Stephen, Thomas M.; DeMaziere, Martine M.; Neefs, Eddy

    2003-08-01

    A heliostat has been designed and built for use in optical remote sensing of the atmosphere. The heliostat uses two flat mirrors to track the sun and direct the sunlight to optical instruments. A stepper motor driven horizontal turntable is used to track the sun in azimuth and support an elevation assembly and a mechanical tower. The stepper motor driven elevation assembly drives an acquisition mirror that tracks the sun in elevation. This mirror directs the solar beam to a secondary mirror fixed on the mechanical tower. The secondary mirror then directs the solar beam along the axis of the tracker for use in measurements. A sensitive, high resolution CCD camera, receives a small part of the solar beam to analyze for fine servo-control. Ground based tests have demonstrated this instrument"s tracking capability for the sun, the moon, stars and for long pathlength sources. Presently, this system is coupled with a high-resolution Brucker 120M spectrometer used to obtain solar absorption spectra. The heliostat directs the solar radiation along the spectrometer optical axis. The pointing precision was measured to be better than 0.5 arcsec. A description of the heliostat is presented, as well as the results of ground tests.

  14. High Precision Sunphotometer using Wide Dynamic Range (WDR) Camera Tracking

    Science.gov (United States)

    Liss, J.; Dunagan, S. E.; Johnson, R. R.; Chang, C. S.; LeBlanc, S. E.; Shinozuka, Y.; Redemann, J.; Flynn, C. J.; Segal-Rosenhaimer, M.; Pistone, K.; Kacenelenbogen, M. S.; Fahey, L.

    2016-12-01

    High Precision Sunphotometer using Wide Dynamic Range (WDR) Camera TrackingThe NASA Ames Sun-photometer-Satellite Group, DOE, PNNL Atmospheric Sciences and Global Change Division, and NASA Goddard's AERONET (AErosol RObotic NETwork) team recently collaborated on the development of a new airborne sunphotometry instrument that provides information on gases and aerosols extending far beyond what can be derived from discrete-channel direct-beam measurements, while preserving or enhancing many of the desirable AATS features (e.g., compactness, versatility, automation, reliability). The enhanced instrument combines the sun-tracking ability of the current 14-Channel NASA Ames AATS-14 with the sky-scanning ability of the ground-based AERONET Sun/sky photometers, while extending both AATS-14 and AERONET capabilities by providing full spectral information from the UV (350 nm) to the SWIR (1,700 nm). Strengths of this measurement approach include many more wavelengths (isolated from gas absorption features) that may be used to characterize aerosols and detailed (oversampled) measurements of the absorption features of specific gas constituents. The Sky Scanning Sun Tracking Airborne Radiometer (3STAR) replicates the radiometer functionality of the AATS-14 instrument but incorporates modern COTS technologies for all instruments subsystems. A 19-channel radiometer bundle design is borrowed from a commercial water column radiance instrument manufactured by Biospherical Instruments of San Diego California (ref, Morrow and Hooker)) and developed using NASA funds under the Small Business Innovative Research (SBIR) program. The 3STAR design also incorporates the latest in robotic motor technology embodied in Rotary actuators from Oriental motor Corp. having better than 15 arc seconds of positioning accuracy. Control system was designed, tested and simulated using a Hybrid-Dynamical modeling methodology. The design also replaces the classic quadrant detector tracking sensor with a

  15. Precision cosmology with time delay lenses: High resolution imaging requirements

    Energy Technology Data Exchange (ETDEWEB)

    Meng, Xiao -Lei [Beijing Normal Univ., Beijing (China); Univ. of California, Santa Barbara, CA (United States); Treu, Tommaso [Univ. of California, Santa Barbara, CA (United States); Univ. of California, Los Angeles, CA (United States); Agnello, Adriano [Univ. of California, Santa Barbara, CA (United States); Univ. of California, Los Angeles, CA (United States); Auger, Matthew W. [Univ. of Cambridge, Cambridge (United Kingdom); Liao, Kai [Beijing Normal Univ., Beijing (China); Univ. of California, Santa Barbara, CA (United States); Univ. of California, Los Angeles, CA (United States); Marshall, Philip J. [Stanford Univ., Stanford, CA (United States)

    2015-09-28

    Lens time delays are a powerful probe of cosmology, provided that the gravitational potential of the main deflector can be modeled with sufficient precision. Recent work has shown that this can be achieved by detailed modeling of the host galaxies of lensed quasars, which appear as ``Einstein Rings'' in high resolution images. The distortion of these arcs and counter-arcs, as measured over a large number of pixels, provides tight constraints on the difference between the gravitational potential between the quasar image positions, and thus on cosmology in combination with the measured time delay. We carry out a systematic exploration of the high resolution imaging required to exploit the thousands of lensed quasars that will be discovered by current and upcoming surveys with the next decade. Specifically, we simulate realistic lens systems as imaged by the Hubble Space Telescope (HST), James Webb Space Telescope (JWST), and ground based adaptive optics images taken with Keck or the Thirty Meter Telescope (TMT). We compare the performance of these pointed observations with that of images taken by the Euclid (VIS), Wide-Field Infrared Survey Telescope (WFIRST) and Large Synoptic Survey Telescope (LSST) surveys. We use as our metric the precision with which the slope γ' of the total mass density profile ρtot∝ r–γ' for the main deflector can be measured. Ideally, we require that the statistical error on γ' be less than 0.02, such that it is subdominant to other sources of random and systematic uncertainties. We find that survey data will likely have sufficient depth and resolution to meet the target only for the brighter gravitational lens systems, comparable to those discovered by the SDSS survey. For fainter systems, that will be discovered by current and future surveys, targeted follow-up will be required. Furthermore, the exposure time required with upcoming facilitites such as JWST, the Keck Next Generation Adaptive

  16. Research Progress of Key Technology of High-Speed and High Precision Motorized Spindles

    Institute of Scientific and Technical Information of China (English)

    XIONG Wan-li; MI Hai-qing; HUANG Hon-gwu

    2005-01-01

    High speed machining and high precision machining are two tendencies of the manufacturing technology worldwide. The motorized spindle is the core component of the machine tools for achieving the high speed and high precise machining, which affects the general development level of the machine tools to a great extent. Progress of the key techniques is reviewed in this paper, in which the high speed and high precision spindle bearings, the dynamical and thermal characteristics of spindles, the design technique of the high frequency motors and the drivers, the anti-electromagnetic damage technique of the motors, and the machining and assembling technique are involved. Finally, tha development tendencies of the motorized spindles are presented.

  17. Performance of a highly loaded two stage axial-flow fan

    Science.gov (United States)

    Ruggeri, R. S.; Benser, W. A.

    1974-01-01

    A two-stage axial-flow fan with a tip speed of 1450 ft/sec (442 m/sec) and an overall pressure ratio of 2.8 was designed, built, and tested. At design speed and pressure ratio, the measured flow matched the design value of 184.2 lbm/sec (83.55kg/sec). The adiabatic efficiency at the design operating point was 85.7 percent. The stall margin at design speed was 10 percent. A first-bending-mode flutter of the second-stage rotor blades was encountered near stall at speeds between 77 and 93 percent of design, and also at high pressure ratios at speeds above 105 percent of design. A 5 deg closed reset of the first-stage stator eliminated second-stage flutter for all but a narrow speed range near 90 percent of design.

  18. High-precision Mg isotopic systematics of bulk chondrites

    Science.gov (United States)

    Schiller, Martin; Handler, Monica R.; Baker, Joel A.

    2010-08-01

    Variations of the mass-independent abundance of 26Mg ( δ26Mg*) and stable Mg ( δ25Mg) isotope composition of chondrites are important because they constrain the homogeneity of 26Al and Mg isotopes in the proto-planetary disc and the validity of the short-lived 26Al-to- 26Mg chronometer applied to meteorites. We present high-precision Mg isotope data and Al/Mg ratios of chondrites representing nearly all major chondrite classes, including a step-leaching experiment on the CM2 chondrite Murchison. δ26Mg* variations in leachates of Murchison representing acid soluble material are ≤ 30 times smaller than reported for neutron-rich isotopes of Ti and Cr and do not reveal resolvable deficits in δ26Mg* (-0.002 to + 0.118‰). Very small variations in δ26Mg* anomalies in bulk chondrites (-0.006 to + 0.019‰) correlate with increasing 27Al/ 24Mg ratios and δ50Ti, reflecting the variable presence of calcium-aluminium-rich inclusions (CAIs) in some types of carbonaceous chondrites. Similarly, release of radiogenic 26Mg produced by 26Al decay from CAI material in the step-leaching of Murchison best explains the high δ26Mg* observed in the last, aggressive, leaching steps of this experiment. Overall, the observed variations in δ26Mg* are small and potential differences beyond that which result from the presence of CAI-like material cannot be detected within the analytical uncertainties of this study (± 0.004‰). The results do not allow radical heterogeneity of 26Al (≥±30%) or measurable Mg nucleosynthetic heterogeneity (≥±0.005‰) to have existed on a planetesimal scale in the proto-planetary disc. Combined with published δ26Mg* data for CAIs, the bulk chondrite data yield a precise initial ( 26Al/ 27Al) 0 = (5.21 ± 0.06) × 10 -5 and δ26Mg* = -0.0340 ± 0.0016‰ for the Solar System. However, it is not possible with the currently available data to determine with certainty whether CAIs and the material from which planetesimals accreted including

  19. High precision optical finishing of lightweight silicon carbide aspheric mirror

    Science.gov (United States)

    Kong, John; Young, Kevin

    2010-10-01

    Critical to the deployment of large surveillance optics into the space environment is the generation of high quality optics. Traditionally, aluminum, glass and beryllium have been used; however, silicon carbide becomes of increasing interest and availability due to its high strength. With the hardness of silicon carbide being similar to diamond, traditional polishing methods suffer from slow material removal rates, difficulty in achieving the desired figure and inherent risk of causing catastrophic damage to the lightweight structure. Rather than increasing structural capacity and mass of the substrate, our proprietary sub-aperture aspheric surface forming technology offers higher material removal rates (comparable to that of Zerodur or Fused Silica), a deterministic approach to achieving the desired figure while minimizing contact area and the resulting load on the optical structure. The technology performed on computer-controlled machines with motion control software providing precise and quick convergence of surface figure, as demonstrated by optically finishing lightweight silicon carbide aspheres. At the same time, it also offers the advantage of ideal pitch finish of low surface micro-roughness and low mid-spatial frequency error. This method provides a solution applicable to all common silicon carbide substrate materials, including substrates with CVD silicon carbide cladding, offered by major silicon carbide material suppliers. This paper discusses a demonstration mirror we polished using this novel technology. The mirror is a lightweight silicon carbide substrate with CVD silicon carbide cladding. It is a convex hyperbolic secondary mirror with 104mm diameter and approximately 20 microns aspheric departure from best-fit sphere. The mirror has been finished with surface irregularity of better than 1/50 wave RMS @632.8 nm and surface micro-roughness of under 2 angstroms RMS. The technology has the potential to be scaled up for manufacturing capabilities of

  20. High precision refractometry based on Fresnel diffraction from phase plates.

    Science.gov (United States)

    Tavassoly, M Taghi; Naraghi, Roxana Rezvani; Nahal, Arashmid; Hassani, Khosrow

    2012-05-01

    When a transparent plane-parallel plate is illuminated at a boundary region by a monochromatic parallel beam of light, Fresnel diffraction occurs because of the abrupt change in phase imposed by the finite change in refractive index at the plate boundary. The visibility of the diffraction fringes varies periodically with changes in incident angle. The visibility period depends on the plate thickness and the refractive indices of the plate and the surrounding medium. Plotting the phase change versus incident angle or counting the visibility repetition in an incident-angle interval provides, for a given plate thickness, the refractive index of the plate very accurately. It is shown here that the refractive index of a plate can be determined without knowing the plate thickness. Therefore, the technique can be utilized for measuring plate thickness with high precision. In addition, by installing a plate with known refractive index in a rectangular cell filled with a liquid and following the described procedures, the refractive index of the liquid is obtained. The technique is applied to measure the refractive indices of a glass slide, distilled water, and ethanol. The potential and merits of the technique are also discussed.

  1. High-Precision Direct Mass Determination of Unstable Isotopes

    CERN Multimedia

    2002-01-01

    The extension of systematic high-precision measurements of the nuclear mass to nuclei far from the valley of $\\beta$ stability is of great interest in nuclear physics and astrophysics. The mass, or binding energy, is a fundamental gross property and a key input parameter for nuclear matter calculations. It is also a sensitive probe for collective and single-particle effects in nuclear structure. \\\\ \\\\ For such purposes, nuclear masses need to be known to an accuracy of about 10$^{-7}$ (i.e. $\\Delta$M~$\\leq$~10~keV for A~=~100). To resolve a particular mass from its nuclear isomers and isobars, resolving power of 10$^6$ are often required. To achieve this, the ions delivered by the on-line mass separator ISOLDE are confined in a Penning quadrupole trap. This trap is placed in the very homogeneous and stable magnetic field of a superconducting magnet. Here, the cyclotron frequency and hence the mass are determined. \\\\ \\\\ The first measurements using this new technique have been completed for a long chain of Cs ...

  2. High precision predictions for exclusive $VH$ production at the LHC

    CERN Document Server

    Li, Ye

    2014-01-01

    We present a resummation-improved prediction for $VH$ + 0 jets production at the Large Hadron Collider. We focus on highly-boosted final states in the presence of jet veto to suppress the $t{\\bar t}$ background. In this case, conventional fixed-order calculations are plagued by the existence of large Sudakov logarithms $\\alpha_s^n \\log^m (p_T^{veto}/Q)$ for $Q\\sim m_V + m_H$ which lead to unreliable predictions as well as large theoretical uncertainties, and thus limit the accuracy when comparing experimental measurements to the Standard Model. In this work, we show that the resummation of Sudakov logarithms beyond the next-to-next-to-leading-log accuracy, combined with the next-to-next-to-leading order calculation, reduces the scale uncertainty and stabilizes the perturbative expansion in the region where the vector bosons carry large transverse momentum. Our result improves the precision with which Higgs properties can be determined from LHC measurements using boosted Higgs techniques.

  3. A portable laser system for high precision atom interferometry experiments

    CERN Document Server

    Schmidt, Malte; Giorgini, Antonio; Tino, Guglielmo M; Peters, Achim

    2010-01-01

    We present a modular rack-mounted laser system for the cooling and manipulation of neutral rubidium atoms which has been developed for the portable gravimeter GAIN, an atom interferometer that will be capable of performing high precision gravity measurements directly at sites of geophysical interest. This laser system is designed to be compact, mobile and robust, yet it still offers improvements over many conventional laboratory-based laser systems. Our system is contained in a standard 19" rack and emits light at five different wavelengths simultaneously on up to 12 fibre ports at a total output power of 800 mW. These wavelengths can be changed and switched between ports in less than a microsecond. The setup includes two phase-locked Raman lasers with a phase noise spectral density of less than 1 \\mu rad/sqrt(Hz) in the frequency range in which our gravimeter is most sensitive to noise. We characterize this laser system and evaluate the performance limits it imposes on an interferometer.

  4. Engine for Miniature High-Precision Propulsion System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose a Phase I SBIR research project that will result in a feasibility demonstration of a miniature divert engine producing precise impulse bits smaller than...

  5. A Low-Cost, High-Precision Navigator Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Toyon Research Corporation proposes to develop and demonstrate a prototype low-cost precision navigation system using commercial-grade gyroscopes and accelerometers....

  6. Interferometric Star Tracker for High Precision Pointing Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Optical Physics Company (OPC) proposes to adapt the precision star tracker it is currently developing under several DoD contracts for deep space lasercom beam...

  7. French Meteor Network for High Precision Orbits of Meteoroids

    Science.gov (United States)

    Atreya, P.; Vaubaillon, J.; Colas, F.; Bouley, S.; Gaillard, B.; Sauli, I.; Kwon, M. K.

    2011-01-01

    There is a lack of precise meteoroids orbit from video observations as most of the meteor stations use off-the-shelf CCD cameras. Few meteoroids orbit with precise semi-major axis are available using film photographic method. Precise orbits are necessary to compute the dust flux in the Earth s vicinity, and to estimate the ejection time of the meteoroids accurately by comparing them with the theoretical evolution model. We investigate the use of large CCD sensors to observe multi-station meteors and to compute precise orbit of these meteoroids. An ideal spatial and temporal resolution to get an accuracy to those similar of photographic plates are discussed. Various problems faced due to the use of large CCD, such as increasing the spatial and the temporal resolution at the same time and computational problems in finding the meteor position are illustrated.

  8. High Precise Internal Friction Calculation for Force Vibration Mode

    Institute of Scientific and Technical Information of China (English)

    LIANG Li-Min; FEI Guang-Tao; SHUI Jia-Peng; CUI Ping; WU Bing; CHEN Xiao-Ming; LUI Ke-Tao

    2005-01-01

    @@ For the necessity of measuring the small phase difference of internal friction, a detailed comparison is carried out among the fast Fourier transformation (FFT), correlation function and three-parameter sine wave curve-fit methods. The comparison shows that the three-parameter sine wave curve-fit method can obtain more precise phase angle difference than correlation methods. Compared with the FFT algorithm, the three-parameter sine wave curve-fit method can obtain more precise frequency values.

  9. PENTATRAP. A novel Penning-trap system for high-precision mass measurements

    Energy Technology Data Exchange (ETDEWEB)

    Doerr, Andreas

    2015-01-21

    The novel Penning-trap mass spectrometer PENTATRAP aims at mass-ratio determinations of medium-heavy to heavy ions with relative uncertainties below 10{sup -11}. From the mass ratios of certain ion species, the corresponding mass differences will be determined with sub-eV/c{sup 2} uncertainties. These mass differences are relevant for neutrino-mass experiments, a test of special relativity and tests of bound-state QED. Means to obtain the required precision are very stable trapping fields, the use of highly-charged ions produced by EBITs, a non-destructive cyclotron-frequency determination scheme employing detectors with single-ion sensitivity and a five-trap tower, that allows for measurement schemes being insensitive to magnetic field drifts. Within this thesis, part of the detection electronics was set up and tested under experimental conditions. A single-trap setup was realized. A Faraday cup in the trap tower enabled the proper adjustment of the settings of the beamline connecting the EBIT and the Penning-trap system, resulting in the first trapping of ions at PENTATRAP. A stabilization of switched voltages in the beamline and detailed studies of ion bunch characteristics allowed for reproducible loading of only a few ions. Detection of the axial oscillation of the trapped ions gave hints that in some cases, even single ions had been trapped. Furthermore, valuable conclusions about necessary modifications of the setup could be drawn.

  10. High-precision, high-throughput stability determinations facilitated by robotics and a semiautomated titrating fluorometer.

    Science.gov (United States)

    Edgell, Marshall Hall; Sims, Dorothy A; Pielak, Gary J; Yi, Fang

    2003-06-24

    The use of statistical modeling to test hypotheses concerning the determinants of protein structure requires stability data (e.g., the free energy of denaturation in H(2)O, DeltaG(HOH)) from hundreds of protein mutants. Fluorescence-monitored chemical denaturation provides a convenient method for high-precision, high-throughput DeltaG(HOH) determination. For eglin c we find that a throughput of about 20 min per protein can be attained in a two-channel semiautomated titrating fluorometer. We find also that the use of robotics for protein purification and preparation of the solutions for chemical denaturation gives highly precise DeltaG(HOH) values in which the standard deviation of values from multiple preparations (+/-0.051 kcal/mol) differs very little from multiple measurements from a single preparation (+/-0.040 kcal/mol). Since the variance introduced into model fitting by DeltaG(HOH) increases as the square of measurement error, there is a premium on precision. In fact, the fraction of stability behavior explicable by otherwise perfect models goes from 98% to only 50% over the error range commonly reported for chemical denaturation measurements (0.1-0.6 kcal/mol). We have found that the precision of chemical denaturation DeltaG(HOH) measurements depends most heavily on the precision of the instrument used, followed by protein purity and the capacity to precisely prepare the solutions used for titrations.

  11. Radio emission from Supernovae and High Precision Astrometry

    Science.gov (United States)

    Perez-Torres, M. A.

    1999-11-01

    The present thesis work makes contributions in two scientific fronts: differential astrometry over the largest angular scales ever attempted (approx. 15 arcdegrees) and numerical simulations of radio emission from very young supernovae. In the first part, we describe the results of the use of very-long-baseline interferometry (VLBI) in one experiment designed to measure with very high precision the angular distance between the radio sources 1150+812 (QSO) and 1803+784 (BL Lac). We observed the radio sources on 19 November 1993 using an intercontinental array of radio telescopes, which simultaneously recorded at 2.3 and 8.4 GHz. VLBI differential astrometry is capable, Nature allowing, of yielding source positions with precisions well below the milliarcsecond level. To achieve this precision, we first had to accurately model the rotation of the interferometric fringes via the most precise models of Earth Orientation Parameters (EOP; precession, polar motion and UT1, nutation). With this model, we successfully connected our phase delay data at both frequencies and, using difference astrometric techniques, determined the coordinates of 1803+784 relative to those of 1150+812-within the IERS reference frame--with an standard error of about 0.6 mas in each coordinate. We then corrected for several effects including propagation medium (mainly the atmosphere and ionosphere), and opacity and source-structure effects within the radio sources. We stress that our dual-frequency measurements allowed us to accurately subtract the ionosphere contribution from our data. We also used GPS-based TEC measurements to independently find the ionosphere contribution, and showed that these contributions agree with our dual-frequency measurements within about 2 standard deviations in the less favorables cases (the longest baselines), but are usually well within one standard deviation. Our estimates of the relative positions, whether using dual-frequency-based or GPS-based ionosphere

  12. Simultaneous Precision Gravimetry and Magnetic Gradiometry with a Bose-Einstein Condensate: A High Precision, Quantum Sensor.

    Science.gov (United States)

    Hardman, K S; Everitt, P J; McDonald, G D; Manju, P; Wigley, P B; Sooriyabandara, M A; Kuhn, C C N; Debs, J E; Close, J D; Robins, N P

    2016-09-23

    A Bose-Einstein condensate is used as an atomic source for a high precision sensor. A 5×10^{6}  atom F=1 spinor condensate of ^{87}Rb is released into free fall for up to 750 ms and probed with a T=130  ms Mach-Zehnder atom interferometer based on Bragg transitions. The Bragg interferometer simultaneously addresses the three magnetic states |m_{f}=1,0,-1⟩, facilitating a simultaneous measurement of the acceleration due to gravity with a 1000 run precision of Δg/g=1.45×10^{-9} and the magnetic field gradient to a precision of 120  pT/m.

  13. Research on a High-Precision Delay Circuit in Data Acquisition Systems

    Institute of Scientific and Technical Information of China (English)

    MA Kai; SU Hong-qi; YANG Gong-xun

    2006-01-01

    This paper presents a novel precision delay circuit design for high-speed data acquisition systems. Many studies have suggested that various advanced electronic measurement apparatuses require that the delay circuit should have a high precision and a short delay interval. Practically, however, such measurement apparatuses are low in precision and long in delay interval at present. The structure and function of a data acquisition system is introduced first; then the principle of ramp-based precision delay circuits and the digitally programmable delay generator is studied and the precision delay circuit is designed. The authors also demonstrated 8-bit programmable delay circuits with a timing precision of 10 ps. Therefore the programmable precision delay circuit here presented has a higher precision, shorter interval and more detectable function than any other precision delay circuit.

  14. High Precision GNSS Guidance for Field Mobile Robots

    Directory of Open Access Journals (Sweden)

    Ladislav Jurišica

    2012-11-01

    Full Text Available In this paper, we discuss GNSS (Global Navigation Satellite System guidance for field mobile robots. Several GNSS systems and receivers, as well as multiple measurement methods and principles of GNSS systems are examined. We focus mainly on sources of errors and investigate diverse approaches for precise measuring and effective use of GNSS systems for real‐ time robot localization. The main body of the article compares two GNSS receivers and their measurement methods. We design, implement and evaluate several mathematical methods for precise robot localization.

  15. Seismicity analysis in Indonesia region from high precision hypocenter location

    Science.gov (United States)

    Nugraha, Andri; Shiddiqi, Hasbi; Widiyantoro, Sri; Ramdhan, Mohamad; Wandono, Wandono

    2015-04-01

    As a complex tectonic region, Indonesia has a high seismicity rate which is related to subduction and collision as well as strike-slip fault. High-precision earthquake locations with adequate relocation method and proper velocity model are necessary for seismicity analysis. We used nearly 25,000 earthquakes that were relocated using double-difference method. In our relocation process, we employed teleseismic, regional, and local P-wave arrival times. Furthermore, we employed regional-global nested velocity models that take into account the subduction slab in the study region by using a 3D model for area inside and a 1D model for area outside Indonesia. Relocation results show shifted hypocenters that are generally perpendicular to the trench. Beneath western Sunda arc, the Wadati-Benioff Zone (WBZ) extents to a depth of about 300 km and depicts a gently dipping slab. The WBZ beneath eastern Sunda arc extends deeper to about 500 km and depicts a steep slab geometry. In the Sunda-Banda transition zone, we found anomalously low seismicity beneath the oceanic-continental transition region. The WBZ of the severely curved Banda arc extends to a depth of about 600 km and depicts a two-slab model. In the Molucca collision zone, seismicity clearly depicts two opposing slabs of the Molucca sea plate, i.e. to the east and to the west. Around Sulawesi region, most earthquakes are related to the north Sulawesi trench and depict subducted slab beneath the northern part of the island. In Sumatra region, we identified a seismic gap in the WBZ between 70 km and 150 km. Seismicity gaps are also detected beneath particular regions, e.g. Mentawai region, and several parts along the subducted slab. Similar to the Sumatra region, beneath eastern Sunda arc, seismic gap in WBZ is also detected but deeper, i.e. at depths of 150 km to 250 km. Furthermore, we used global centroid moment tensor catalog data available for earthquakes with magnitude 5.0 or greater. In general, focal mechanism

  16. Axially connected nanowire core-shell p-n junctions: a composite structure for high-efficiency solar cells.

    Science.gov (United States)

    Wang, Sijia; Yan, Xin; Zhang, Xia; Li, Junshuai; Ren, Xiaomin

    2015-01-01

    A composite nanostructure for high-efficiency solar cells that axially connects nanowire core-shell p-n junctions is proposed. By axially connecting the p-n junctions in one nanowire, the solar spectrum is separated and absorbed in the top and bottom cells with respect to the wavelength. The unique structure of nanowire p-n junctions enables substantial light absorption along the nanowire and efficient radial carrier separation and collection. A coupled three-dimensional optoelectronic simulation is used to evaluate the performance of the structure. With an excellent current matching, a promising efficiency of 19.9% can be achieved at a low filling ratio of 0.283 (the density of the nanowire array), which is much higher than the tandem axial p-n junctions.

  17. Precision Teaching in the High School Classroom: A Commentary

    Science.gov (United States)

    Brophy, Jere E.

    1978-01-01

    In a review of Breuning's study of conventional vs. precision teaching (TM 503 458), Brophy praises the research design used. However, the interpretation and reporting of Breuning's data are questioned. The effects of instructional method have been confused with the effects of incentive manipulation. The practicality and ethical justification are…

  18. A high precision magnetometer based on pulsed NMR

    NARCIS (Netherlands)

    Prigl, R; Haeberlen, U; Jungmann, K; Putlitz, GZ; vonWalter, P

    1996-01-01

    A magnetometer based on pulsed proton magnetic resonance has been developed and constructed. The system will be employed for an accurate measurement of the absolute magnetic field in the region of 1.45 T in a precision experiment on the muon's anomalous magnetic moment at the Brookhaven National Lab

  19. CUSB-II: A high precision electromagnetic spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Schamberger, R.D.; Heintz, U.; Lee-Franzini, J.; Lovelock, D.M.J.; Narain, M.; Willins, J.; Yanagisawa, C. (SUNY, Stony Brook, NY (United States)); Tuts, P.M.; Franzini, P.; Kanekal, S.; Wu, Q.W. (Columbia Univ., New York, NY (United States))

    1991-11-15

    The design, construction and performance of a very compact precision electromagnetic spectrometer is described. The CUSB-II detectors has been used to study {gamma} spectroscopy, search for exotic particles and measure properties of the B and B{sup *} mesons at the Cornell Electron Storage Ring. (orig.).

  20. High-precision Stellar Limb-darkening in Exoplanetary Transits

    Science.gov (United States)

    Morello, G.; Tsiaras, A.; Howarth, I. D.; Homeier, D.

    2017-09-01

    Characterization of the atmospheres of transiting exoplanets relies on accurate measurements of the extent of the optically thick area of the planet at multiple wavelengths with a precision ≲ 100 parts per million (ppm). Next-generation instruments onboard the James Webb Space Telescope (JWST) are expected to achieve ∼10 ppm precision for several tens of targets. A similar precision can be obtained in modeling only if other astrophysical effects, including the stellar limb-darkening, are properly accounted for. In this paper, we explore the limits on precision due to the mathematical formulas currently adopted to approximate the stellar limb-darkening, and due to the use of limb-darkening coefficients obtained either from stellar-atmosphere models or empirically. We recommend the use of a two-coefficient limb-darkening law, named “power-2,” which outperforms other two-coefficient laws adopted in the exoplanet literature in most cases, and particularly for cool stars. Empirical limb-darkening based on two-coefficient formulas can be significantly biased, even if the light-curve residuals are nearly photon-noise limited. We demonstrate an optimal strategy to fitting for the four-coefficient limb-darkening in the visible, using prior information on the exoplanet orbital parameters to break some of the degeneracies that otherwise would prevent the convergence of the fit. Infrared observations taken with the JWST will provide accurate measurements of the exoplanet orbital parameters with unprecedented precision, which can be used as priors to improve the stellar limb-darkening characterization, and therefore the inferred exoplanet parameters, from observations in the visible, such as those taken with Kepler/K2, the JWST, and other past and future instruments.

  1. A comparative study of complications of cataract surgery with phacoemulsification in eyes with high and normal axial length

    Directory of Open Access Journals (Sweden)

    Hamid Fesharaki

    2012-01-01

    Conclusions: As the results illustrate, in this survey, age and high axial length were statistically significant risk factors for incidence of intraoperative complications of cataract surgery with phacoemulsification technique. Anticipation of these complications and also preparation and prophylactic measures may decrease incidence of these complications.

  2. ADVANCED DESIGN SOLUTIONS FOR HIGH-PRECISION WOODWORKING MACHINES

    Directory of Open Access Journals (Sweden)

    Giuseppe Lucisano

    2016-03-01

    Full Text Available With the aim at performing the highest precision during woodworking, a mix of alternative approaches, fruitfully integrated in a common design strategy, is essential. This paper represents an overview of technical solutions, recently developed by authors, in design of machine tools and their final effects on manufacturing. The most advanced solutions in machine design are reported side by side with common practices or little everyday expedients. These design actions are directly or indirectly related to the rational use of materials, sometimes very uncommon, as in the case of magnetorheological fluids chosen to implement an active control in speed and force on the electro-spindle, and permitting to improve the quality of wood machining. Other actions are less unusual, as in the case of the adoption of innovative anti-vibration supports for basement. Tradition or innovation, all these technical solutions contribute to the final result: the highest precision in wood machining.

  3. Electroweak Precision Physics from Low to High Energies

    CERN Document Server

    Heinemeyer, S

    2007-01-01

    Electroweak precision observables (EWPO) can give valuable information about the last unknown paramter of the Standard Model (SM), the Higgs-boson mass M_H^SM. EWPO can also restrict the parameter space of new physics models (NPM) such as the Minimal Supersymmetric Standard Model (MSSM). We review the respective constraints from the W boson mass, the effective leptonic mixing angle, the anomalous magnetic moment of the muon and electric dipole moments. Within the MSSM also the lightest Higgs-boson mass, M_h, is discussed as a precision observable. The EWPO, supplemented with B physics observables and astrophysical data can be used to determine indirectly the preferred mass scales of Supersymmetry and M_h.

  4. Flow performance of highly loaded axial fan with bowed rotor blades

    Science.gov (United States)

    Chen, L.; Liu, X. J.; Yang, A. L.; Dai, R.

    2013-12-01

    In this paper, a partial bowed rotor blade was proposed for a newly designed high loaded axial fan. The blade was positively bowed 30 degrees from hub to 30 percent spanwise position. Flows of radial blade and bowed blade fans were numerically compared for various operation conditions. Results show that the fan's performance is improved. At the designed condition with flow coefficient of 0.52, the efficiency of the bowed blade fan is increased 1.44% and the static pressure rise is increased 11%. Comparing the flow structures, it can be found that the separated flow in the bowed fan is reduced and confined within 20 percent span, which is less than the 35 percent in the radial fan. It means that the bowed blade generates negative blade force and counteracts partial centrifugal force. It is alleviates the radial movements of boundary layers in fan's hub region. Flow losses due to 3D mixing are reduced in the rotor. Inlet flow to downstream stator is also improved.

  5. A Developed Methodology in Design of Highly Loaded Tandem Axial Flow Compressor Stage

    Directory of Open Access Journals (Sweden)

    Masoud Boroomand

    2016-01-01

    Full Text Available This study, primarily reports the development of a 3D design procedure for axial flow tandem compressor stages and then the method is used to design a highly loaded tandem stage. In order to investigate the effects of such arrangement, another stage with conventional loading with single blade for both rotor and stator rows is designed with similar specification. In order to ease the comparison of results, chord lengths and hub/shroud geometries are selected with the same dimensions. At the next stage a three dimensional numerical model is developed to predict the characteristic performance of both tandem and conventional stages. The model is validated with the experimental results of NASA-67 stage and the level of the accuracy of the model is presented. Employing the model to simulate the performance of both stages at design and offdesign operating points show that, tandem stage can provide higher pressure ratio with acceptable efficiency. In another word, tandem stage is capable having the same pressure ratio at lower rotational speed. The safe operation domain and loss mechanism in tandem stage are also discussed in this report.

  6. Yale High Energy Physics Research: Precision Studies of Reactor Antineutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Heeger, Karsten M. [Yale Univ., New Haven, CT (United States)

    2014-09-13

    This report presents experimental research at the intensity frontier of particle physics with particular focus on the study of reactor antineutrinos and the precision measurement of neutrino oscillations. The experimental neutrino physics group of Professor Heeger and Senior Scientist Band at Yale University has had leading responsibilities in the construction and operation of the Daya Bay Reactor Antineutrino Experiment and made critical contributions to the discovery of non-zero$\\theta_{13}$. Heeger and Band led the Daya Bay detector management team and are now overseeing the operations of the antineutrino detectors. Postdoctoral researchers and students in this group have made leading contributions to the Daya Bay analysis including the prediction of the reactor antineutrino flux and spectrum, the analysis of the oscillation signal, and the precision determination of the target mass yielding unprecedented precision in the relative detector uncertainty. Heeger's group is now leading an R\\&D effort towards a short-baseline oscillation experiment, called PROSPECT, at a US research reactor and the development of antineutrino detectors with advanced background discrimination.

  7. Genetic variants on chromosome 1q41 influence ocular axial length and high myopia.

    Directory of Open Access Journals (Sweden)

    Qiao Fan

    Full Text Available As one of the leading causes of visual impairment and blindness, myopia poses a significant public health burden in Asia. The primary determinant of myopia is an elongated ocular axial length (AL. Here we report a meta-analysis of three genome-wide association studies on AL conducted in 1,860 Chinese adults, 929 Chinese children, and 2,155 Malay adults. We identified a genetic locus on chromosome 1q41 harboring the zinc-finger 11B pseudogene ZC3H11B showing genome-wide significant association with AL variation (rs4373767, β = -0.16 mm per minor allele, P(meta =2.69 × 10(-10. The minor C allele of rs4373767 was also observed to significantly associate with decreased susceptibility to high myopia (per-allele odds ratio (OR =0.75, 95% CI: 0.68-0.84, P(meta =4.38 × 10(-7 in 1,118 highly myopic cases and 5,433 controls. ZC3H11B and two neighboring genes SLC30A10 and LYPLAL1 were expressed in the human neural retina, retinal pigment epithelium, and sclera. In an experimental myopia mouse model, we observed significant alterations to gene and protein expression in the retina and sclera of the unilateral induced myopic eyes for the murine genes ZC3H11A, SLC30A10, and LYPLAL1. This supports the likely role of genetic variants at chromosome 1q41 in influencing AL variation and high myopia.

  8. High precision survey and alignment techniques in accelerator construction

    CERN Document Server

    Gervaise, J

    1974-01-01

    Basic concepts of precision surveying are briefly reviewed, and an historical account is given of instruments and techniques used during the construction of the Proton Synchrotron (1954-59), the Intersecting Storage Rings (1966-71), and the Super Proton Synchrotron (1971). A nylon wire device, distinvar, invar wire and tape, and recent automation of the gyrotheodolite and distinvar as well as auxiliary equipment (polyurethane jacks, Centipede) are discussed in detail. The paper ends summarizing the present accuracy in accelerator metrology, giving an outlook of possible improvement, and some aspects of staffing for the CERN Survey Group. (0 refs).

  9. The effect of variable stator on performance of a highly loaded tandem axial flow compressor stage

    Science.gov (United States)

    Eshraghi, Hamzeh; Boroomand, Masoud; Tousi, Abolghasem M.; Fallah, Mohammad Toude; Mohammadi, Ali

    2016-06-01

    Increasing the aerodynamic load on compressor blades helps to obtain a higher pressure ratio in lower rotational speeds. Considering the high aerodynamic load effects and structural concerns in the design process, it is possible to obtain higher pressure ratios compared to conventional compressors. However, it must be noted that imposing higher aerodynamic loads results in higher loss coefficients and deteriorates the overall performance. To avoid the loss increase, the boundary layer quality must be studied carefully over the blade suction surface. Employment of advanced shaped airfoils (like CDAs), slotted blades or other boundary layer control methods has helped the designers to use higher aerodynamic loads on compressor blades. Tandem cascade is a passive boundary layer control method, which is based on using the flow momentum to control the boundary layer on the suction surface and also to avoid the probable separation caused by higher aerodynamic loads. In fact, the front pressure side flow momentum helps to compensate the positive pressure gradient over the aft blade's suction side. Also, in comparison to the single blade stators, tandem variable stators have more degrees of freedom, and this issue increases the possibility of finding enhanced conditions in the compressor off-design performance. In the current study, a 3D design procedure for an axial flow tandem compressor stage has been applied to design a highly loaded stage. Following, this design is numerically investigated using a CFD code and the stage characteristic map is reported. Also, the effect of various stator stagger angles on the compressor performance and especially on the compressor surge margin has been discussed. To validate the CFD method, another known compressor stage is presented and its performance is numerically investigated and the results are compared with available experimental results.

  10. The Effect of Variable Stator on Performance of a Highly Loaded Tandem Axial Flow Compressor Stage

    Institute of Scientific and Technical Information of China (English)

    Hamzeh Eshraghi; Masoud Boroomand; Abolghasem M.Tousi; Mohammad Toude Fallah; Ali Mohammadi

    2016-01-01

    Increasing the aerodynamic load on compressor blades helps to obtain a higher pressure ratio in lower rotational speeds.Considering the high aerodynamic load effects and structural concerns in the design process,it is possible to obtain higher pressure ratios compared to conventional compressors.However,it must be noted that imposing higher aerodynamic loads results in higher loss coefficients and deteriorates the overall performance.To avoid the loss increase,the boundary layer quality must be studied carefully over the blade suction surface.Employment of advanced shaped airfoils (like CDAs),slotted blades or other boundary layer control methods has helped the designers to use higher aerodynamic loads on compressor blades.Tandem cascade is a passive boundary layer control method,which is based on using the flow momentum to control the boundary layer on the suction surface and also to avoid the probable separation caused by higher aerodynamic loads.In fact,the front pressure side flow momentum helps to compensate the positive pressure gradient over the aft blade's suction side.Also,in comparison to the single blade stators,tandem variable stators have more degrees of freedom,and this issue increases the possibility of finding enhanced conditions in the compressor off-design performance.In the current study,a 3D design procedure for an axial flow tandem compressor stage has been applied to design a highly loaded stage.Following,this design is numerically investigated using a CFD code and the stage characteristic map is reported.Also,the effect of various stator stagger angles on the compressor performance and especially on the compressor surge margin has been discussed.To validate the CFD method,another known compressor stage is presented and its performance is numerically investigated and the results are compared with available experimental results.

  11. High-precision temperature control and stabilization using a cryocooler.

    Science.gov (United States)

    Hasegawa, Yasuhiro; Nakamura, Daiki; Murata, Masayuki; Yamamoto, Hiroya; Komine, Takashi

    2010-09-01

    We describe a method for precisely controlling temperature using a Gifford-McMahon (GM) cryocooler that involves inserting fiber-reinforced-plastic dampers into a conventional cryosystem. Temperature fluctuations in a GM cryocooler without a large heat bath or a stainless-steel damper at 4.2 K are typically of the order of 200 mK. It is particularly difficult to control the temperature of a GM cryocooler at low temperatures. The fiber-reinforced-plastic dampers enabled us to dramatically reduce temperature fluctuations at low temperatures. A standard deviation of the temperature fluctuations of 0.21 mK could be achieved when the temperature was controlled at 4.200 0 K using a feedback temperature control system with two heaters. Adding the dampers increased the minimum achievable temperature from 3.2 to 3.3 K. Precise temperature control between 4.200 0 and 300.000 K was attained using the GM cryocooler, and the standard deviation of the temperature fluctuations was less than 1.2 mK even at 300 K. This technique makes it possible to control and stabilize the temperature using a GM cryocooler.

  12. High-precision analysis of SF6 at ambient level

    Directory of Open Access Journals (Sweden)

    J. S. Lim

    2013-09-01

    Full Text Available This work reports on the development of a technique for the precise analysis of ambient SF6. This technique, which involves a gas chromatograph/electron capture detector (GC-ECD coupled with an Activated Alumina-F1 (AA-F1 column, performed well in the measurements, particularly in terms of accuracy, which complies with the World Meteorological Organization (WMO-recommended compatibility of 0.02 ppt. Compared to the Porapak Q technique, we observed a sharper peak shape for the SF6 stream, which substantiates the improvement in the analytical precision. The traceability to the WMO scale was tested by calibrating the GC-ECD/AA-F1 analyser using five SF6 standards provided by the WMO/Global Atmosphere Watch (GAW Central Calibration Laboratory (CCL for SF6 (NOAA, United States of America. After calibration by various methods, the GC-ECD/AA-F1 accurately estimated the mole fraction of SF6 in the working standard prepared by the World Calibration Centre for SF6 operated by the Korea Meteorological Administration (KMA/Korea Research Institute of Standards and Science (KRISS. Among the calibration methods, the two-point calibration method emerged to be the most economical procedure in terms of the data quality and measurement time. It was found that the KRISS scale of SF6/N2 was biased by 0.13 ppt when compared to the WMO scale of SF6/air; this bias is probably due to a different matrix.

  13. Axial myopathy

    DEFF Research Database (Denmark)

    Witting, Nanna; Andersen, Linda K; Vissing, John

    2016-01-01

    musculature involvement in the majority of myopathies in which paraspinal musculature was examined. Even in diseases named after a certain pattern of non-axial muscle affection, such as facioscapulohumeral and limb girdle muscular dystrophies, affection of the axial musculature was often severe and early...

  14. Development of a highly efficient brushless dc motor utilizing both radial and axial air gaps

    Science.gov (United States)

    Kang, K. J.; Jang, G. H.; Sung, S. J.; Chang, J. H.

    2012-04-01

    This research proposes an effective structure for a brushless dc motor utilizing both radial and axial air gaps. The proposed motor generates torque in both the radial and axial air gaps, while the conventional motor generates torque only in the radial air gap. The proposed motor was optimized to minimize the electromagnetic loss of the motor to increase the effective air gap length and fill-factor of the coil while decreasing the saturation of the core at the same time. The electromagnetic loss was reduced by 35% in comparison with a conventional motor.

  15. Evaporative cooling and coherent axial oscillations of highly charged ions in a penning trap.

    Science.gov (United States)

    Hobein, M; Solders, A; Suhonen, M; Liu, Y; Schuch, R

    2011-01-07

    Externally, in an electron beam ion trap, generated Ar16+ ions were retrapped in a Penning trap and evaporatively cooled in their axial motion. The cooling was observed by a novel extraction technique based on the excitation of a coherent axial oscillation which yields short ion bunches of well-defined energies. The initial temperature of the ion cloud was decreased by a factor of more than 140 within 1 s, while the phase-space density of the coldest extracted ion pulses was increased by a factor of up to about 9.

  16. Narrow CSF space at high convexity and high midline areas in idiopathic normal pressure hydrocephalus detected by axial and coronal MRI

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Makoto [Iwate Medical University, Department of Radiology, Morioka (Japan); Honda, Satoshi [St. Luke' s International Hospital, Department of Radiology, Tokyo (Japan); Yuasa, Tatsuhiko; Iwamura, Akihide [Kohnodai Hospital, National Center of Neurology and Psychiatry, Department of Neurology, Ichikawa (Japan); Shibata, Eri [Iwate Medical University, Department of Neuropsychiatry, Morioka (Japan); Ohba, Hideki [Iwate Medical University, Department of Neurology, Morioka (Japan)

    2008-02-15

    The aim of this study was to determine the performance of axial and coronal magnetic resonance imaging (MRI) in detecting the narrowing of the cerebrospinal fluid (CSF) space at the high convexity and high midline areas, which is speculated to be one of the clinical characteristics of idiopathic normal pressure hydrocephalus (iNPH). We retrospectively examined axial and coronal T1-weighted images of 14 iNPH patients and 12 age-matched controls. The narrowness of the CSF space at the high convexity/midline was blindly evaluated by five raters using a continuous confidence rating scale for receiver operating characteristic (ROC) analysis. Axial and coronal imaging accurately determined the presence of the narrow cisterns/sulci at the high convexity/midline and was capable of predicting probable/definite iNPH with a high degree of accuracy. there were also no significant differences in the detection of this finding between the axial and coronal images. Both axial and coronal T1-weighted MRI can detect the narrow CSF space at the high convexity/midline accurately and may therefore facilitate clinicians in choosing a management strategy for iNPH patients. (orig.)

  17. A High Precision, Optical Polarimeter to Measure Inclinations of High Mass X-Ray Binaries

    CERN Document Server

    Wiktorowicz, Sloane J

    2008-01-01

    We present commissioning data for the POLISH instrument obtained on the Hale 5-m telescope. The goal of this high precision polarimeter is to constrain orbital inclination of high mass X-ray binaries and to therefore obtain independent mass estimates for their black hole companions. We have obtained photon shot noise limited precision on standard stars, and we have measured the polarization of bright stars at the part per million level on a nightly basis. Systematic effects have been reduced to less than 1% of the measured polarization for polarized sources and to the part per million level for weakly polarized sources. The high sensitivity of this instrument to asymmetry suggests that valuable contributions will be made in many other fields, including studies of extrasolar planets, debris disks, and stellar astrophysics.

  18. A high precision, compact electromechanical ground rotation sensor

    Science.gov (United States)

    Dergachev, V.; DeSalvo, R.; Asadoor, M.; Bhawal, A.; Gong, P.; Kim, C.; Lottarini, A.; Minenkov, Y.; Murphy, C.; O'Toole, A.; Peña Arellano, F. E.; Rodionov, A. V.; Shaner, M.; Sobacchi, E.

    2014-05-01

    We present a mechanical rotation sensor consisting of a balance pivoting on a tungsten carbide knife edge. These sensors are important for precision seismic isolation systems, as employed in land-based gravitational wave interferometers and for the new field of rotational seismology. The position sensor used is an air-core linear variable differential transformer with a demonstrated noise floor of {1}{ × 10^{-11}}textrm { m}/sqrt{textrm {Hz}}. We describe the instrument construction and demonstrate low noise operation with a noise floor upper bound of {5.7}{ × 10^{-9}}textrm { rad}/sqrt{textrm {Hz}} at 10 mHz and {6.4}{ × 10^{-10}}textrm { rad}/sqrt{textrm {Hz}} at 0.1 Hz. The performance of the knife edge hinge is compatible with a behaviorur free of noise from dislocation self-organized criticality.

  19. Aerospace Laser Ignition/Ablation Variable High Precision Thruster

    Science.gov (United States)

    Campbell, Jonathan W. (Inventor); Edwards, David L. (Inventor); Campbell, Jason J. (Inventor)

    2015-01-01

    A laser ignition/ablation propulsion system that captures the advantages of both liquid and solid propulsion. A reel system is used to move a propellant tape containing a plurality of propellant material targets through an ignition chamber. When a propellant target is in the ignition chamber, a laser beam from a laser positioned above the ignition chamber strikes the propellant target, igniting the propellant material and resulting in a thrust impulse. The propellant tape is advanced, carrying another propellant target into the ignition chamber. The propellant tape and ignition chamber are designed to ensure that each ignition event is isolated from the remaining propellant targets. Thrust and specific impulse may by precisely controlled by varying the synchronized propellant tape/laser speed. The laser ignition/ablation propulsion system may be scaled for use in small and large applications.

  20. A high precision, compact electromechanical ground rotation sensor

    Energy Technology Data Exchange (ETDEWEB)

    Dergachev, V., E-mail: volodya@caltech.edu [LIGO Laboratory, California Institute of Technology, MS 100-36, Pasadena, California 91125 (United States); DeSalvo, R. [LIGO Laboratory, California Institute of Technology, MS 100-36, Pasadena, California 91125 (United States); University of Sannio, C.so Garibaldi 107, Benevento 82100 (Italy); Asadoor, M. [Mayfield Senior School, 500 Bellefontaine Street, Pasadena, California 91105 (United States); Oklahoma State University, 219 Student Union, Stillwater, Oklahoma 74074 (United States); Bhawal, A. [Arcadia High School, 180 Campus Drive, Arcadia, California 91007 (United States); Carnegie Mellon University, 5000 Forbes Ave, Pittsburgh, Pennsylvania 15213 (United States); Gong, P. [Department of Precision Instrument, Tsinghua University, Beijing 100084 (China); School of Industrial and System Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0205 (United States); Kim, C. [California Institute of Technology, Pasadena, California 91125 (United States); Lottarini, A. [Department of Computer Science, University of Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Department of Computer Science, Columbia University, 1214 Amsterdam Avenue, New York, New York 10027 (United States); Minenkov, Y. [Sezione INFN Tor Vergata, via della Ricerca Scientifica  1, 00133 Roma (Italy); Murphy, C. [School of Physics, The University of Western Australia, 35 Stirling Highway, Crawley, Perth, Western Australia 6009 (Australia); University of Melbourne Grattan Street, Parkville VIC 3010 (Australia); O' Toole, A. [University of California, Los Angeles, 405 Hilgard Ave, Los Angeles, California 90095 (United States); Michigan Technological University, 1400 Townsend Dr, Houghton, Michigan 49931 (United States); Peña Arellano, F. E. [National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan); and others

    2014-05-15

    We present a mechanical rotation sensor consisting of a balance pivoting on a tungsten carbide knife edge. These sensors are important for precision seismic isolation systems, as employed in land-based gravitational wave interferometers and for the new field of rotational seismology. The position sensor used is an air-core linear variable differential transformer with a demonstrated noise floor of 1 × 10{sup −11}m/√( Hz ). We describe the instrument construction and demonstrate low noise operation with a noise floor upper bound of 5.7 × 10{sup −9} rad /√( Hz ) at 10 mHz and 6.4 × 10{sup −10} rad /√( Hz ) at 0.1 Hz. The performance of the knife edge hinge is compatible with a behaviorur free of noise from dislocation self-organized criticality.

  1. Design of High-Precision Frequency Measure System Based on CPLD Time Delay Unit

    Energy Technology Data Exchange (ETDEWEB)

    Feng Qian; Ding Wei; Wang Hao, E-mail: fengqian@eqhb.gov.cn [Institute of Seismology, China Earthquake Administration, 40 Hongshan Road, Wuchang District, Wuhan (China)

    2011-02-01

    Introduced a method for high-precision frequency measurement, which do do not need the complicated measuring control circumstance. CPLD is used for improving the precision of measurement by the method of quantization time-delay. High precision frequency adjustable module based on the method has been used on the photoelectricity data acquisition system. Frequency accuracy is -8.306x10{sup -10}, which meet the requirement of instrument.

  2. High precision (14 bit), high density (octal) analog to digital converter for spectroscopy applications

    Science.gov (United States)

    Subramaniam, E. T.; Jain, Mamta; Bhowmik, R. K.; Tripon, Michel

    2008-10-01

    Nuclear and particle physics experiments with large number of detectors require signal processing and data collection strategies that call for the ability to collect large amount of data while not sacrificing the precision and accuracy of the data being collected. This paper deals with the development of a high precision pulse peak detection, analog to digital converter (ADC) module with eight independent channels in plug-in daughter card motherboard model, best suited for spectroscopy experiments. This module provides multiple channels without cross-talk and of 14 bit resolution, while maintaining high density (each daughter card has an area of just 4.2″×0.51″) and exhibiting excellent integral nonlinearity (≤±2 mV or ±0.02% full scale reading) and differential nonlinearity (≤±1%). It was designed, developed and tested, in house, and gives added advantages of cost effectiveness and ease of maintenance.

  3. Precision manufacturing

    CERN Document Server

    Dornfeld, David

    2008-01-01

    Today there is a high demand for high-precision products. The manufacturing processes are now highly sophisticated and derive from a specialized genre called precision engineering. Precision Manufacturing provides an introduction to precision engineering and manufacturing with an emphasis on the design and performance of precision machines and machine tools, metrology, tooling elements, machine structures, sources of error, precision machining processes and precision process planning. As well as discussing the critical role precision machine design for manufacturing has had in technological developments over the last few hundred years. In addition, the influence of sustainable manufacturing requirements in precision processes is introduced. Drawing upon years of practical experience and using numerous examples and illustrative applications, David Dornfeld and Dae-Eun Lee cover precision manufacturing as it applies to: The importance of measurement and metrology in the context of Precision Manufacturing. Th...

  4. High Performance and Increased Precision Techniques for Feynman Loop Integrals

    Science.gov (United States)

    Kato, K.; de Doncker, E.; Ishikawa, T.; Kapenga, J.; Olagbemi, O.; Yuasa, F.

    2016-10-01

    For the investigation of physics within and beyond the Standard Model, a precise evaluation of higher order corrections in perturbative quantum field theory is required. We have worked on the development of a computational method for Feynman loop integrals with a fully numerical approach. It is based on numerical integration and extrapolation techniques. In this paper, we describe the status and new developments in our techniques for the numerical computation of Feynman loop integrals. Separation of ultra-violet divergences is important for the renormalization procedure. In our analyses, the separation can be done numerically. For 2-loop integrals we have performed the calculations for up to 4-point functions, and for 2-point functions we can handle up to 4- loop integrals. We report the status and accuracy of the computations with detailed numerical comparisons to results in the literature, in order to demonstrate that our method will evolve into an important component of automated systems for the study of higher-order radiative corrections.

  5. High-precision timeline for Earth's most severe extinction.

    Science.gov (United States)

    Burgess, Seth D; Bowring, Samuel; Shen, Shu-zhong

    2014-03-04

    The end-Permian mass extinction was the most severe loss of marine and terrestrial biota in the last 542 My. Understanding its cause and the controls on extinction/recovery dynamics depends on an accurate and precise age model. U-Pb zircon dates for five volcanic ash beds from the Global Stratotype Section and Point for the Permian-Triassic boundary at Meishan, China, define an age model for the extinction and allow exploration of the links between global environmental perturbation, carbon cycle disruption, mass extinction, and recovery at millennial timescales. The extinction occurred between 251.941 ± 0.037 and 251.880 ± 0.031 Mya, an interval of 60 ± 48 ka. Onset of a major reorganization of the carbon cycle immediately precedes the initiation of extinction and is punctuated by a sharp (3‰), short-lived negative spike in the isotopic composition of carbonate carbon. Carbon cycle volatility persists for ∼500 ka before a return to near preextinction values. Decamillenial to millennial level resolution of the mass extinction and its aftermath will permit a refined evaluation of the relative roles of rate-dependent processes contributing to the extinction, allowing insight into postextinction ecosystem expansion, and establish an accurate time point for evaluating the plausibility of trigger and kill mechanisms.

  6. High precision Hugoniot measurements of D2 near maximum compression

    Science.gov (United States)

    Benage, John; Knudson, Marcus; Desjarlais, Michael

    2015-11-01

    The Hugoniot response of liquid deuterium has been widely studied due to its general importance and to the significant discrepancy in the inferred shock response obtained from early experiments. With improvements in dynamic compression platforms and experimental standards these results have converged and show general agreement with several equation of state (EOS) models, including quantum molecular dynamics (QMD) calculations within the Generalized Gradient Approximation (GGA). This approach to modeling the EOS has also proven quite successful for other materials and is rapidly becoming a standard approach. However, small differences remain among predictions obtained using different local and semi-local density functionals; these small differences show up in the deuterium Hugoniot at ~ 30-40 GPa near the region of maximum compression. Here we present experimental results focusing on that region of the Hugoniot and take advantage of advancements in the platform and standards, resulting in data with significantly higher precision than that obtained in previous studies. These new data may prove to distinguish between the subtle differences predicted by the various density functionals. Results of these experiments will be presented along with comparison to various QMD calculations. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin company, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  7. Efficacy of High Intensity Exercise on Disease Activity and Cardiovascular Risk in Active Axial Spondyloarthritis: A Randomized Controlled Pilot Study

    OpenAIRE

    Silje Halvorsen Sveaas; Inger Jorid Berg; Sella Aarrestad Provan; Anne Grete Semb; Kåre Birger Hagen; Nina Vøllestad; Camilla Fongen; Inge C Olsen; Annika Michelsen; Thor Ueland; Pål Aukrust; Kvien, Tore K; Hanne Dagfinrud

    2014-01-01

    BACKGROUND: Physical therapy is recommended for the management of axial spondyloarthritis (axSpA) and flexibility exercises have traditionally been the main focus. Cardiovascular (CV) diseases are considered as a major health concern in axSpA and there is strong evidence that endurance and strength exercise protects against CV diseases. Therefore, the aim of this study was to investigate the efficacy of high intensity endurance and strength exercise on disease activity and CV health in patien...

  8. Disturbances in the afflux of aerodynamically highly stressed axial blowers. Stoerungen in der Zustroemung von aerodynamisch hochbelasteten Axialventilatoren

    Energy Technology Data Exchange (ETDEWEB)

    Kosyna, G.; Krasmann, H. (Technische Univ. Braunschweig, Pfleiderer-Inst. fuer Stroemungsmaschinen (Germany))

    1992-08-01

    When installing blowers, it is not always possible to ensure an optimum fluidic afflux, which can thus produce a change in the operating behaviour compared with the design. Using as an example an axial blower blade with small hub ratio and high aerodynamic blade load, under simulated non-rotation symmetrical allflux conditions, it was possible to show that with the examined distrubance configuration no extreme worsening was produced with regard to the achievable pressure increases and efficiencies of the blower stage. (orig.).

  9. New linear piezomotors for high-force precise positioning applications

    Science.gov (United States)

    Le Letty, Ronan; Claeyssen, Frank; Barillot, Francois; Six, Marc F.; Bouchilloux, Philippe

    1998-07-01

    Piezomotors are an increasingly competitive alternative to electromagnetic stepper motors, especially in applications where large bandwidths and/or precise positioning control are desired. Piezomotors use a combination of electromechanical and frictional forces and, compared to conventional electromagnetic motors, have the advantages that no power supply is required to maintain the motor in position and no lubrication is necessary in the device. The operating principle of these motors relies on the use of an ultrasonic vibration, which is created via the piezoelectric effect (at resonance in most cases), in order to generate vibration forces at the `stator/rotor' contact interface. A mechanical preload is also applied at this contact interface and is responsible for the motor's holding force at rest. To meet the specifications of an aerospace application, we developed a new design of Linear PiezoMotors (LPMs). The first prototype we built shows very promising results, and makes the LPM a serious candidate to replace conventional stepper motors. The LPM features the following characteristics: a standing force of 100 N, a blocked force of 37 N, a maximum actuation speed of 23 mm/s, a maximum run of 10 mm, a mass of 500 g, an electrical power of 2.2 W, and a position accuracy superior to 1 micrometers . To our knowledge, the driving force delivered by the LPM has never before been achieved in resonant devices. This paper describes the physical operating principles of the LPM, as well as the modeling tools and experimental techniques we used for its development. Several implementation schemes are also presented and show the wide range of possible applications offered by the linear piezomotor.

  10. Development of highly effective cryogenic printed circuit heat exchanger (PCHE) with low axial conduction

    Science.gov (United States)

    Baek, Seungwhan; Kim, Jin-Hyuck; Jeong, Sangkwon; Jung, Jeheon

    2012-07-01

    This paper presents the results of an experimental investigation of the thermal and hydraulic performance of a printed circuit heat exchanger (PCHE) for use in the cryogenic temperature region. Compact PCHEs with multiple corrugated, longitudinal flow microchannels were fabricated using chemical etching and diffusion bonding to evaluate their thermal and hydraulic performance. The testing of the PCHEs was conducted with helium gas at cryogenic temperatures. The pressure drop and thermal effectiveness values obtained from the measured pressures and temperatures are discussed. The thermal performance was predominantly affected by the axial conduction heat transfer in the low Reynolds number ranges of theses experiments. A simple performance calculation model is presented, and the effectiveness calculated from the model is compared with the experimental data. The design of the cryogenic PCHE was then modified to reduce axial conduction losses.

  11. Design and development of a high-precision, high-payload telescope dual-drive system

    Science.gov (United States)

    Worthington, Michael S.; Beets, Timothy A.; Beno, Joseph H.; Mock, Jason R.; Murphy, Brian T.; South, Brian J.; Good, John M.

    2010-07-01

    A high precision, dual drive system has been designed and developed for the Wide Field Upgrade to the Hobby-Eberly Telescope* at McDonald Observatory in support of the Hobby-Eberly Telescope Dark Energy Experiment‡. Analysis, design and controls details will be of interest to designers of large scale, high precision robotic motion devices. The drive system positions the 19,000 kg star tracker to a precision of less than 5 microns along its 4-meter travel. While positioning requirements remain essentially equal to the existing HET, tracker mass increases by a factor greater than 5. The 10.5-meter long tracker is driven at each end by planetary roller screws, each having two distinct drive sources dictated by the desired operation: one slowly rotates the screw when tracking celestial objects and the second rotates the nut for rapid displacements. Key results of the roller screw rotordynamics analysis are presented. A description of the complex bearing arrangement providing required degrees of freedom as well as the impact of a detailed Failure Modes and Effects Analysis addressing necessary safety systems is also presented. Finite element analysis results demonstrate how mechanical springs increase the telescope's natural frequency response by 22 percent. The critical analysis and resulting design is provided.

  12. Low-pressure reversible axial fan with straight profile blades and relatively high efficiency

    OpenAIRE

    2012-01-01

    The paper presents the design and operating characteristics of a model of reversible axial fan with only one impeller, whose reversibility is achieved by changing the direction of rotation. The fan is designed for the purpose of providing alternating air circulation in wood dryers in order to reduce the consumption of electricity for the fan and increase energy efficiency of the entire dryer. To satisfy the reversibility of flow, the shape of the blade profile is symmetrical along the l...

  13. Low-pressure reversible axial fan with straight profile blades and relatively high efficiency

    OpenAIRE

    Spasić Živan T.; Milanović Saša M.; Šušteršič Vanja M.; Nikolić Boban D.

    2012-01-01

    The paper presents the design and operating characteristics of a model of reversible axial fan with only one impeller, whose reversibility is achieved by changing the direction of rotation. The fan is designed for the purpose of providing alternating air circulation in wood dryers in order to reduce the consumption of electricity for the fan and increase energy efficiency of the entire dryer. To satisfy the reversibility of flow, the shape of the blade profile is symmetrical along the l...

  14. Evidence of effective axial U (1 ) symmetry restoration at high temperature QCD

    Science.gov (United States)

    Tomiya, A.; Cossu, G.; Aoki, S.; Fukaya, H.; Hashimoto, S.; Kaneko, T.; Noaki, J.; Jlqcd Collaboration

    2017-08-01

    We study the axial U (1 ) symmetry at a finite temperature in two-flavor lattice QCD. Employing the Möbius domain-wall fermions, we generate gauge configurations slightly above the critical temperature Tc with different lattice sizes L =2 - 4 fm . Our action allows frequent topology tunneling while keeping good chiral symmetry close enough to that of overlap fermions. This allows us to recover full chiral symmetry by an overlap/domain-wall reweighting. Above the phase transition, a strong suppression of the low-lying modes is observed in both overlap and domain-wall Dirac spectra. We, however, find a sizable violation of the Ginsparg-Wilson relation in the Möbius domain-wall Dirac eigenmodes, which dominates the signals of the axial U (1 ) symmetry breaking near the chiral limit. We also find that the use of the overlap fermion only in the valence sector is dangerous since it suffers from the artifacts due to partial quenching. Reweighting the Möbius domain-wall fermion determinant to that of the overlap fermion, we observe the axial U(1) breaking to vanish in the chiral limit, which is stable against the changes of the lattice volume and lattice spacing.

  15. Technique for high axial shielding factor performance of large-scale, thin, open-ended, cylindrical Metglas magnetic shields

    CERN Document Server

    Malkowski, S; Hona, B; Mattie, C; Woods, D; Yan, H; Plaster, B; 10.1063/1.3605665

    2011-01-01

    Metglas 2705M is a low-cost commercially-available, high-permeability Cobalt-based magnetic alloy, provided as a 5.08-cm wide and 20.3-$\\mu$m thick ribbon foil. We present an optimized construction technique for single-shell, large-scale (human-size), thin, open-ended cylindrical Metglas magnetic shields. The measured DC axial and transverse magnetic shielding factors of our 0.61-m diameter and 1.83-m long shields in the Earth's magnetic field were 267 and 1500, for material thicknesses of only 122 $\\mu$m (i.e., 6 foil layers). The axial shielding performance of our single-shell Metglas magnetic shields, obtained without the use of magnetic shaking techniques, is comparable to the performance of significantly thicker, multiple-shell, open-ended Metglas magnetic shields in comparable-magnitude, low-frequency applied external fields reported previously in the literature.

  16. High precision, low disturbance calibration of the High Voltage system of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Marzocchi, Badder

    2017-01-01

    The CMS Electromagnetic Calorimeter is made of scintillating lead tungstate crystals, using avalanche photodiodes (APD) as photo-detectors in the barrel part. The high voltage system, consisting of 1224 channels, biases groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3pct/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  17. High-precision atom localization via controllable spontaneous emission in a cycle-configuration atomic system

    National Research Council Canada - National Science Library

    Ding, Chunling; Li, Jiahua; Yu, Rong; Hao, Xiangying; Wu, Ying

    2012-01-01

    .... Therefore, by detecting the emitted photon one could obtain the position information available, and then we demonstrate high-precision and high-resolution 2D atom localization induced by the quantum...

  18. High precision Symplectic Integrators for the Solar System

    CERN Document Server

    Farrés, Ariadna; Blanes, Sergio; Casas, Fernando; Makazaga, Joseba; Murua, Ander

    2012-01-01

    Using a Newtonian model of the Solar System with all 8 planets, we perform extensive tests on various symplectic integrators of high orders, searching for the best splitting scheme for long term studies in the Solar System. These comparisons are made in Jacobi and Heliocentric coordinates and the implementation of the algorithms is fully detailed for practical use. We conclude that high order integrators should be privileged, with a preference for the new $(10,6,4)$ method of (Blanes et al., 2012)

  19. Precise investigation of the axial ligand substitution mechanism on a hydrogenphosphato-bridged lantern-type platinum(III) binuclear complex in acidic aqueous solution.

    Science.gov (United States)

    Iwatsuki, Satoshi; Mizushima, Chiho; Morimoto, Naoyuki; Muranaka, Shinji; Ishihara, Koji; Matsumoto, Kazuko

    2005-10-31

    Detailed equilibrium and kinetic studies on axial water ligand substitution reactions of the "lantern-type" platinum(III) binuclear complex, [Pt(2)(mu-HPO(4))(4)(H(2)O)(2)](2)(-), with halide and pseudo-halide ions (X(-) = Cl(-), Br(-), and SCN(-)) were carried out in acidic aqueous solution at 25 degrees C with I = 1.0 M. The diaqua Pt(III) dimer complex is in acid dissociation equilibrium in aqueous solution with -log K(h1) = 2.69 +/- 0.04. The consecutive formation constants of the aquahalo complex () and the dihalo complex () were determined spectrophotometrically to be log = 2.36 +/- 0.01 and log = 1.47 +/- 0.01 for the reaction with Cl(-) and log = 2.90 +/- 0.04 and log = 2.28 +/- 0.01 for the reaction with Br(-), respectively. In the kinetic measurements carried out under the pseudo-first-order conditions with a large excess concentration of halide ion compared to that of Pt(III) dimer (C(X)()- > C(Pt)), all of the reactions proceeded via a one-step first-order reaction, which is a contrast to the consecutive two-step reaction for the amidato-bridged platinum(III) binuclear complexes. The conditional first-order rate constant (k(obs)) depended on C(X)()- as well as the acidity of the solution. From kinetic analyses, the rate-limiting step was determined to be the first substitution process that forms the monohalo species, which is in rapid equilibrium with the dihalo complex. The reaction with 4-penten-1-ol was also kinetically investigated to examine the reactivity of the lantern complex with olefin compounds.

  20. SynUTC - high precision time synchronization over ethernet networks

    CERN Document Server

    Höller, R; Horauer, M; Kerö, N; Schmid, U; Schossmaier, K

    2002-01-01

    This article describes our SynUTC (Synchronized Universal Time Coordinated) technology, which enables high-accuracy distribution of GPS time and time synchronization of network nodes connected via standard Ethernet LANs. By means of exchanging data packets in conjunction with moderate hardware support at nodes and switches, an overall worst-case accuracy in the range of some 100 ns can be achieved, with negligible communication overhead. Our technology thus improves the 1 ms-range accuracy achievable by conventional, software-based approaches like NTP by 4 orders of magnitude. Applications can use the high-accuracy global time provided by SynUTC for event timestamping and event generation both at hardware and software level. SynUTC is based upon inserting highly accurate time information into dedicated data packets at the media-independent interface (MII) between the physical layer transceiver and the network controller upon packet transmission and reception, respectively. As a consequence, every node has acc...

  1. In-plane laser forming for high precision alignment

    NARCIS (Netherlands)

    Folkersma, Ger; Römer, Gert-Willem; Brouwer, Dannis; Huis in 't Veld, Bert

    2014-01-01

    Laser microforming is extensively used to align components with submicrometer accuracy, often after assembly. While laser-bending sheet metal is the most common laser-forming mechanism, the in-plane upsetting mechanism is preferred when a high actuator stiffness is required. A three-bridge planar ac

  2. 基于精密测距的红态圆柱钢坯轴心在线检测系统%Research of Hot Cylindrical Billet Axial Lead Position Measurement System Based on Precise Rangefinder

    Institute of Scientific and Technical Information of China (English)

    刘庆运; 朱任之; 景甜甜; 刘涛

    2015-01-01

    红态圆柱钢坯的轴心线相对于模具中心线的偏差对动车组车轮的模压成型具有重要影响。为提高车轮的模压质量和原料成材率,基于高精度激光测距的方法,构建了可用于高温红态圆柱钢坯轴线检测的在线测量系统。首先通过测量位于同一水平截面上的圆柱表面不同4点到相应激光测距传感器的距离,分别得出模具中心线和钢坯轴心线相对于轧机中心线的坐标;然后利用坐标变换方法,计算出钢坯轴心线位置相对于模具中心线的偏差值;最后基于CANopen 协议和通信转换模块构建多传感器检测网络,实现数据的传输与轴心偏差方位的直观显示。通过实际检测实验验证了检测系统与测量算法的有效性。%The position variance of hot cylindrical billet axial lead relative to the mold center line has important influence on the bullet trains compression molding. Based on precise rangefinder,a meas-urement system which used to measuring hot cylindrical billet axial lead was constructed. By measur-ing the distances between the cylindrical billet and laser displacement sensors which fixed on the mill, the coordinates of mold center and the billet axial lead can be determined. According to the coordinate transformation,the position variance of hot cylindrical billet axial lead relative to the mold center line was worked out. Based on CANopen protocol and communication conversion module,the multi-sensor detection network was proposed to realize the data transmission and visual displaying. The practical detection tests were given to illustrate the validity of the algorithm and the reliability of the measure-ment system.

  3. High-Precision Registration of Point Clouds Based on Sphere Feature Constraints.

    Science.gov (United States)

    Huang, Junhui; Wang, Zhao; Gao, Jianmin; Huang, Youping; Towers, David Peter

    2016-12-30

    Point cloud registration is a key process in multi-view 3D measurements. Its precision affects the measurement precision directly. However, in the case of the point clouds with non-overlapping areas or curvature invariant surface, it is difficult to achieve a high precision. A high precision registration method based on sphere feature constraint is presented to overcome the difficulty in the paper. Some known sphere features with constraints are used to construct virtual overlapping areas. The virtual overlapping areas provide more accurate corresponding point pairs and reduce the influence of noise. Then the transformation parameters between the registered point clouds are solved by an optimization method with weight function. In that case, the impact of large noise in point clouds can be reduced and a high precision registration is achieved. Simulation and experiments validate the proposed method.

  4. Design of High Precision Horizontal Control Network for Large-Scale Hydropower Project

    Institute of Scientific and Technical Information of China (English)

    ZHANG Zhenglu; LUO Changlin; DENG Yong; XIE Niansheng

    2006-01-01

    A new solution of combination network of GPS and high precise distance measurements with EDM is proposed. Meanwhile, it's inadvisable only using GPS network without distance measurements. Three schemes: terrestrial network, GPS network and combination network are discussed for horizontal control network design of Xiangjiaba Dam in view of precision, reliability, coordinate and outlay in detail.

  5. A high precision radiation-tolerant LVDT conditioning module

    CERN Document Server

    Masi, A; Losito, R; Peronnard, P; Secondo, R; Spiezia, G

    2014-01-01

    Linear variable differential transformer (LVDT) position sensors are widely used in particle accelerators and nuclear plants, thanks to their properties of contact-less sensing, radiation tolerance, infinite resolution, good linearity and cost efficiency. Many applications require high reading accuracy, even in environments with high radiation levels, where the conditioning electronics must be located several hundred meters away from the sensor. Sometimes even at long distances the conditioning module is still exposed to ionizing radiation. Standard off-the-shelf electronic conditioning modules offer limited performances in terms of reading accuracy and long term stability already with short cables. A radiation tolerant stand-alone LVDT conditioning module has been developed using Commercial Off-The-Shelf (COTS) components. The reading of the sensor output voltages is based on a sine-fit algorithm digitally implemented on an FPGA ensuring few micrometers reading accuracy even with low signal-to-noise ratios. ...

  6. Ultrasmooth, Highly Spherical Monocrystalline Gold Particles for Precision Plasmonics

    KAUST Repository

    Lee, You-Jin

    2013-12-23

    Ultrasmooth, highly spherical monocrystalline gold particles were prepared by a cyclic process of slow growth followed by slow chemical etching, which selectively removes edges and vertices. The etching process effectively makes the surface tension isotropic, so that spheres are favored under quasi-static conditions. It is scalable up to particle sizes of 200 nm or more. The resulting spherical crystals display uniform scattering spectra and consistent optical coupling at small separations, even showing Fano-like resonances in small clusters. The high monodispersity of the particles we demonstrate should facilitate the self-assembly of nanoparticle clusters with uniform optical resonances, which could in turn be used to fabricate optical metafluids. Narrow size distributions are required to control not only the spectral features but also the morphology and yield of clusters in certain assembly schemes. © 2013 American Chemical Society.

  7. High Precision Assembly of Thin Mirror X-ray Telescopes

    Science.gov (United States)

    Schattenburg, Mark

    Lightweight high resolution x-ray telescope optics are one of the key technologies under development for next-generation x-ray telescopes. The ultimate goal of this effort is to realize optics with spatial resolution rivaling Chandra (spindle structure. While very light weight, this process resulted in ~1 arc min resolution. We want to achieve ~100 times better with similar mass. A group at NASA GSFC has recently demonstrated an alternative thin-glass assembly procedure that has achieved ~7 arc sec resolution with x-ray tests. Further progress towards 1 arc-sec will require mirrors with improved figure, lower stress coatings, improved alignment, better metrology, and low stress bonding. Many of the difficulties with current mirror assembly practice stem from the use of epoxy as a bonding agent. Epoxy has many disadvantages, including high shrinkage, large CTE and creep, resin aging effects, water absorption, outgassing, low tensile strength, exothermicity, and requiring large amounts of time and/or heat to cure. These effects can cause errors that become â€oefrozen in― to the bond with no possibility of correction. We propose to investigate replacing epoxy with low temperature, low shrinkage solder alloys. We use these solders in conjunction with high power, millisec-long pulses from a fiber IR laser to deliver controlled amounts of heat into the bond area. We have demonstrated that laser pulses can be used to actuate carefully designed bonds by permanently compressing or expanding a very thin and brief surface melt in the solder by amounts controlled in the nanoscale range, allowing post assembly correction of the mirror mount points. We believe this technology will be one of the keys to realize a sub-1 arc-sec thin-glass x-ray telescope.

  8. A high-precision algorithm for axisymmetric flow

    Directory of Open Access Journals (Sweden)

    A. Gokhman

    1995-01-01

    Full Text Available We present a new algorithm for highly accurate computation of axisymmetric potential flow. The principal feature of the algorithm is the use of orthogonal curvilinear coordinates. These coordinates are used to write down the equations and to specify quadrilateral elements following the boundary. In particular, boundary conditions for the Stokes' stream-function are satisfied exactly. The velocity field is determined by differentiating the stream-function. We avoid the use of quadratures in the evaluation of Galerkin integrals, and instead use splining of the boundaries of elements to take the double integrals of the shape functions in closed form. This is very accurate and not time consuming.

  9. Combination spindle-drive system for high precision machining

    Science.gov (United States)

    Gerth, Howard L.

    1977-07-26

    A combination spindle-drive is provided for fabrication of optical quality surface finishes. Both the spindle-and-drive utilize the spindle bearings for support, thereby removing the conventional drive-means bearings as a source of vibration. An airbearing spindle is modified to carry at the drive end a highly conductive cup-shaped rotor which is aligned with a stationary stator to produce torque in the cup-shaped rotor through the reaction of eddy currents induced in the rotor. This arrangement eliminates magnetic attraction forces and all force is in the form of torque on the cup-shaped rotor.

  10. AVERAGE GEOMETRICAL FEATURES OF THE ELECTRON WAVE PACKAGES DISTRIBUTION IN METALLIC CONDUCTORS WITH PULSED AXIAL CURRENT OF HIGH DENSITY

    Directory of Open Access Journals (Sweden)

    M. I. Baranov

    2016-11-01

    Full Text Available Purpose. Calculation and experimental determination of average geometrical features of distributing of macroscopic electron wave packages (EWP in round cylindrical metallic conductors with the pulsed axial current of high density. Methodology. Theoretical bases of the electrical engineering, bases of atomic and quantum physics, electrophysics bases of technique of high voltage and high pulsed currents. Results. The results of the conducted calculation and experimental researches are resulted on close determination of average geometrical features of distribution of longitudinal and radial EWP of macroscopic sizes in the indicated conductors. These descriptions are included by the average widths of «hot» and «cold» longitudinal and radial areas of conductor, and also average steps of division into the periods of similar areas. Results of the executed calculations and high temperature experiments for average geometrical features of longitudinal EWP in the zincked steel wire of diameter of 1.6 mm and length of 320 mm with the aperiodic impulse of current of temporal form 9 ms/160 ms and by amplitude 745 A coincide within the limits of 19 %. Originality. First with the use of methods of atomic and quantum physics the features of the stochastic distributing and mean values of basic geometrical sizes are analysed macroscopic longitudinal and radial EWP in round cylindrical metallic conductors with the pulsed axial current of high density. Practical value. Drawing on the got results in practice will allow more reliably to forecast geometrical sizes and places of localization of arising up in the probed metallic conductors with pulsed axial current of high density longitudinal and radial EWP.

  11. Unraveling high precision stereocontrol in a triple cascade organocatalytic reaction.

    Science.gov (United States)

    Shinisha, C B; Sunoj, Raghavan B

    2008-11-07

    The mechanism and stereoselectivity in an organocatalyzed triple cascade reaction between an aldehyde, electron deficient olefin and an alpha,beta-unsaturated aldehyde are investigated for the first time using density functional theory. The factors responsible for high levels of observed stereoselectivity (Enders et al., Nature, 2006, 441, 861) towards the generation of cyclohexene carbaldehyde with four contiguous stereocentres are unravelled. The triple cascade reaction, comprising a Michael, Michael and aldol sequence as the key elementary reactions, is studied by identifying the corresponding transition states for the stereoselective C-C bond-formation. In the first Michael addition step between the enamine (derived from the chiral catalyst and propanal) and nitrostyrene, energetically the most preferred mode of addition is found to be between the si-face of (E)-anti-enamine on the si-face of nitrostyrene. The addition of the si-face of the nitroalkane anion on the re-face of the iminium ion (formed between the enal and the catalyst) is the lowest energy pathway for the second Michael addition step. The high level of asymmetric induction is rationalized with the help of relative activation barriers associated with the competitive diastereomeric pathways. Interesting weak interactions, along with the steric effects offered by the bulky alpha-substituent on the pyrrolidine ring, are identified as critical to the stereoselectivity in this triple cascade reaction. The predicted stereoselectivities using computed energetics are found to be in perfect harmony with the experimental stereoselectivities.

  12. Numerical simulation of high-swirl flow in axial turbine stage

    Directory of Open Access Journals (Sweden)

    Straka Petr

    2016-01-01

    Full Text Available This article deals with numerical modelling of flow in an axial turbine stage with prismatic blades which are not equipped with shroud. In this case flow through a radial gap above and below ends of blades leads to generation of strong secondary vortices which significantly affect an effciency of the stage. The main attention is paid to turbulence modelling. Besides a linear model based on Boussinesq approximation a nonlinear model based on higher order closure formula is used. Also an effect of a curvature correction is taken into account.

  13. Design of a high performance low aerodynamic noise axial flow fan

    OpenAIRE

    2007-01-01

    The project starts with a description of the main sources of noise in an axial flow fan for concluding that the thing we should avoid is the trailing edge noise. After that the formulas for designing a fan and an aerodynamics background are presented. Once we get the results of these formulas a low noise optimization is carried on for leading us to a table of results where the main characteristics of design for our fan are obtained. After these tables the design of the fan is obtained with Pr...

  14. High-precision metrology of highly charged ions via relativistic resonance fluorescence.

    Science.gov (United States)

    Postavaru, O; Harman, Z; Keitel, C H

    2011-01-21

    Resonance fluorescence of laser-driven highly charged ions is investigated with regard to precisely measuring atomic properties. For this purpose an ab initio approach based on the Dirac equation is employed that allows for studying relativistic ions. These systems provide a sensitive means to test correlated relativistic dynamics, quantum electrodynamic phenomena and nuclear effects by applying x-ray lasers. We show how the narrowing of sidebands in the x-ray fluorescence spectrum by interference due to an additional optical driving can be exploited to determine atomic dipole or multipole moments to unprecedented accuracy.

  15. High precision, low disturbance calibration of the High Voltage system of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Fasanella, Giuseppe

    2016-01-01

    The CMS Electromagnetic Calorimeter utilizes scintillating lead tungstate crystals, with avalanche photodiodes (APD) as photo-detectors in the barrel part. 1224 HV channels bias groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3pct/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  16. High precision, low disturbance calibration system for the CMS Barrel Electromagnetic Calorimeter High Voltage apparatus

    Science.gov (United States)

    Fasanella, G.

    2017-01-01

    The CMS Electromagnetic Calorimeter utilizes scintillation lead tungstate crystals, with avalanche photodiodes (APD) as photo-detectors in the barrel part. 1224 HV channels bias groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3%/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  17. High precision, medium flux rate CZT spectroscopy for coherent scatter imaging

    Science.gov (United States)

    Greenberg, Joel A.; Hassan, Mehadi; Brady, David J.; Iniewski, Kris

    2016-05-01

    CZT detectors are primary candidates for many next-generation X-ray imaging systems. These detectors are typically operated in either a high precision, low flux spectroscopy mode or a low precision, high flux photon counting mode. We demonstrate a new detector configuration that enables operation in a high precision, medium flux spectroscopy mode, which opens the potential for a variety of new applications in medical imaging, non-destructive testing and baggage scanning. In particular, we describe the requirements of a coded aperture coherent scattering X-ray system that can perform fast imaging with accurate material discrimination.

  18. Stellar Astrophysics Using Ultra-High Precision CCD Time Series Photometry

    Science.gov (United States)

    Howell, S.; Everett, M.; Huber, M.; Ciardi, D.; van Belle, G.

    2001-05-01

    Using time-series CCD photometry and a wide-field imager, we have extended the techniques of differential photometry to provide robust photometric precisions for each star over the entire field of view. Reaching photometric precisions of 2 milli-magnitudes, we produced high cadence light curves for over 12,000 stars at mid- and high galactic latitude. The fraction of stars seen to be variable is higher than the canonical wisdom, being 10-14 will present the details of our techniques, sample light curves, methods to access the data, and a summary of astrophysical uses of such high precision data.

  19. On the Mitigation of Solar Index Variability for High Precision Orbit Determination in Low Earth Orbit

    Science.gov (United States)

    2016-09-16

    Orbit Covariance Estimation and ANalysis (OCEAN) high precision orbit deter- mination tool in order to determine the suitability of each model for...Covariance Estimation and ANalysis (OCEAN) software was used to preform high precision orbit estimations. OCEAN is a highly configurable, database...lowest RMS position difference for each time span is highlighted in bold text . The Jacchia-Bowman 2008 models are labeled as JB08, the NRLMSISE-00

  20. High-Precision Measurements of Brightness Variation of Nereid

    CERN Document Server

    Terai, Tsuyoshi

    2012-01-01

    Nereid, a satellite of Neptune, has a highly eccentric prograde orbit with a semi-major axis larger than 200 Neptune radius and is classified as an irregular satellite. Although the capture origin of irregular satellites has been widely accepted, several previous studies suggest that Nereid was formed in the circumplanetary disk of Neptune and was ejected outward to the present location by Triton. Our time-series photometric observations confirm that the spin is stable and non-chaotic with a period of 11.5 hr as indicated by Grav et al. (2003). The optical colors of Nereid are indistinguishable from those of trans-Neptunian objects and Centaurs, especially those with neutral colors. We also find the consistency of Nereid's rotation with the size-rotation distribution of small outer bodies. It is more likely that Nereid originates in an immigrant body captured from a heliocentric orbit which was 4-5 AU away from Neptune's orbit.

  1. High precision pointing with a multiline spectrometer at the VTT

    Science.gov (United States)

    Staiger, J.

    2012-12-01

    We are investigating the pointing quality of the VTT, Tenerife under the aspect of suitability for long-term heliosesimological observations. Tests have shown that thermal and mechanical loads within the telescope may create spurious image drifts with shift rates of up to 5 arcsec per hour. During daylong recordings this will reduce significantly the effective size of the field-of-view and may infer artificial lateral movements into the data. The underlying problem that not all image position offsets developing during a measurement may be compensated for is common to most high-resolution solar telescopes independently of the type of pointing system used. We are developing new approaches to address this problem which are to be tested in the near future at the VTT. The simulations established so far show that the problem may be reduced by more than 90 %.

  2. DEVELOPMENT FOR HIGH PRECISION SIX COMPONENT STRAIN GAUGE BALANCE

    Institute of Scientific and Technical Information of China (English)

    ZHANGZhao-ming; HANBu-zhang

    2004-01-01

    The measurement accuracy of a wind tunnel balance is the key factor to improve the measurement accuracy for a test model in the wind tunnel. In order to improve the measurement accuracy of the wind tunnel balance, a great deal of investigation is carried out in China. This paper summarizes a program to improve the measurement accuracy of wind tunnel balances. In the program, the investigation is carried out in three aspects (1) designing a drag component of the balance in low interactions (2) choosing high quality foil strain gauges with temperature self-compensation (3) choosing the excellent gauges and mounting them meticulously. As an example, these research achievements are applied in a φ18 six component balance. The measurement accuracy of a GB-04 standard model in a transonic wind tunnel with the φ18 six component balance comes up to the advanced world standard.

  3. Derivative properties from high-precision equations of state.

    Science.gov (United States)

    Haghbakhsh, Reza; Konttorp, Morten; Raeissi, Sona; Peters, Cor J; O'Connell, John P

    2014-12-11

    In this study, the behavior of derivative properties estimated by equations of state, including isochoric heat capacity, isobaric heat capacity, speed of sound, and the Joule-Thomson coefficient for pure compounds and a mixture, has been investigated. The Schmidt-Wagner and Jacobsen-Stewart equations of state were used for predictions of derivative properties of 10 different pure compounds from various nonpolar hydrocarbons, nonpolar cyclic hydrocarbons, polar compounds, and refrigerants. The estimations were compared to experimental data. To evaluate the behavior of mixtures, the extended corresponding states principle (ECS) was studied. Analytical relationships were derived for isochoric heat capacity, isobaric heat capacity, the Joule-Thomson coefficient, and the speed of sound. The ECS calculations were compared to the reference surface data of methane + ethane. The ECS principle was found to generate data of high quality.

  4. A high precision high PSRR bandgap reference with thermal hysteresis protection

    Energy Technology Data Exchange (ETDEWEB)

    Yang Yintang; Li Yani; Zhu Zhangming, E-mail: yanili@mail.xidian.edu.c [Key Laboratory of Wide Band-Gap Semiconductor Materials and Devices of the Ministry of Education, Institute of Microelectronics, Xidian University, Xi' an 710071 (China)

    2010-09-15

    To meet the accuracy requirement for the bandgap voltage reference by the increasing data conversion precision of integrated circuits, a high-order curvature-compensated bandgap voltage reference is presented employing the characteristic of bipolar transistor current gain exponentially changing with temperature variations. In addition, an over-temperature protection circuit with a thermal hysteresis function to prevent thermal oscillation is proposed. Based on the CSMC 0.5 {mu}m 20 V BCD process, the designed circuit is implemented; the active die area is 0.17 x 0.20 mm{sup 2}. Simulation and testing results show that the temperature coefficient is 13.7ppm/K with temperature ranging from -40 to 150 {sup 0}C, the power supply rejection ratio is -98.2 dB, the line regulation is 0.3 mV/V, and the power consumption is only 0.38 mW. The proposed bandgap voltage reference has good characteristics such as small area, low power consumption, good temperature stability, high power supply rejection ratio, as well as low line regulation. This circuit can effectively prevent thermal oscillation and is suitable for on-chip voltage reference in high precision analog, digital and mixed systems. (semiconductor integrated circuits)

  5. SEMICONDUCTOR INTEGRATED CIRCUITS: A high precision high PSRR bandgap reference with thermal hysteresis protection

    Science.gov (United States)

    Yintang, Yang; Yani, Li; Zhangming, Zhu

    2010-09-01

    To meet the accuracy requirement for the bandgap voltage reference by the increasing data conversion precision of integrated circuits, a high-order curvature-compensated bandgap voltage reference is presented employing the characteristic of bipolar transistor current gain exponentially changing with temperature variations. In addition, an over-temperature protection circuit with a thermal hysteresis function to prevent thermal oscillation is proposed. Based on the CSMC 0.5 μm 20 V BCD process, the designed circuit is implemented; the active die area is 0.17 × 0.20 mm2. Simulation and testing results show that the temperature coefficient is 13.7ppm/K with temperature ranging from -40 to 150 °C, the power supply rejection ratio is -98.2 dB, the line regulation is 0.3 mV/V, and the power consumption is only 0.38 mW. The proposed bandgap voltage reference has good characteristics such as small area, low power consumption, good temperature stability, high power supply rejection ratio, as well as low line regulation. This circuit can effectively prevent thermal oscillation and is suitable for on-chip voltage reference in high precision analog, digital and mixed systems.

  6. A Time Projection Chamber for High Accuracy and Precision Fission Cross-Section Measurements

    Energy Technology Data Exchange (ETDEWEB)

    T. Hill; K. Jewell; M. Heffner; D. Carter; M. Cunningham; V. Riot; J. Ruz; S. Sangiorgio; B. Seilhan; L. Snyder; D. M. Asner; S. Stave; G. Tatishvili; L. Wood; R. G. Baker; J. L. Klay; R. Kudo; S. Barrett; J. King; M. Leonard; W. Loveland; L. Yao; C. Brune; S. Grimes; N. Kornilov; T. N. Massey; J. Bundgaard; D. L. Duke; U. Greife; U. Hager; E. Burgett; J. Deaven; V. Kleinrath; C. McGrath; B. Wendt; N. Hertel; D. Isenhower; N. Pickle; H. Qu; S. Sharma; R. T. Thornton; D. Tovwell; R. S. Towell; S.

    2014-09-01

    The fission Time Projection Chamber (fissionTPC) is a compact (15 cm diameter) two-chamber MICROMEGAS TPC designed to make precision cross-section measurements of neutron-induced fission. The actinide targets are placed on the central cathode and irradiated with a neutron beam that passes axially through the TPC inducing fission in the target. The 4p acceptance for fission fragments and complete charged particle track reconstruction are powerful features of the fissionTPC which will be used to measure fission cross-sections and examine the associated systematic errors. This paper provides a detailed description of the design requirements, the design solutions, and the initial performance of the fissionTPC.

  7. Analysis and Design Considerations of a High-Power Density, Dual Air Gap, Axial-Field Brushless, Permanent Magnet Motor.

    Science.gov (United States)

    Cho, Chahee Peter

    1995-01-01

    Until recently, brush dc motors have been the dominant drive system because they provide easily controlled motor speed over a wide range, rapid acceleration and deceleration, convenient control of position, and lower product cost. Despite these capabilities, the brush dc motor configuration does not satisfy the design requirements for the U.S. Navy's underwater propulsion applications. Technical advances in rare-earth permanent magnet materials, in high-power semiconductor transistor technology, and in various rotor position-sensing devices have made using brushless permanent magnet motors a viable alternative. This research investigates brushless permanent magnet motor technology, studying the merits of dual-air gap, axial -field, brushless, permanent magnet motor configuration in terms of power density, efficiency, and noise/vibration levels. Because the design objectives for underwater motor applications include high-power density, high-performance, and low-noise/vibration, the traditional, simplified equivalent circuit analysis methods to assist in meeting these goals were inadequate. This study presents the development and verification of detailed finite element analysis (FEA) models and lumped parameter circuit models that can calculate back electromotive force waveforms, inductance, cogging torque, energized torque, and eddy current power losses. It is the first thorough quantification of dual air-gap, axial -field, brushless, permanent magnet motor parameters and performance characteristics. The new methodology introduced in this research not only facilitates the design process of an axial field, brushless, permanent magnet motor but reinforces the idea that the high-power density, high-efficiency, and low-noise/vibration motor is attainable.

  8. High Resolution Airborne Digital Imagery for Precision Agriculture

    Science.gov (United States)

    Herwitz, Stanley R.

    1998-01-01

    The Environmental Research Aircraft and Sensor Technology (ERAST) program is a NASA initiative that seeks to demonstrate the application of cost-effective aircraft and sensor technology to private commercial ventures. In 1997-98, a series of flight-demonstrations and image acquisition efforts were conducted over the Hawaiian Islands using a remotely-piloted solar- powered platform (Pathfinder) and a fixed-wing piloted aircraft (Navajo) equipped with a Kodak DCS450 CIR (color infrared) digital camera. As an ERAST Science Team Member, I defined a set of flight lines over the largest coffee plantation in Hawaii: the Kauai Coffee Company's 4,000 acre Koloa Estate. Past studies have demonstrated the applications of airborne digital imaging to agricultural management. Few studies have examined the usefulness of high resolution airborne multispectral imagery with 10 cm pixel sizes. The Kodak digital camera integrated with ERAST's Airborne Real Time Imaging System (ARTIS) which generated multiband CCD images consisting of 6 x 106 pixel elements. At the designated flight altitude of 1,000 feet over the coffee plantation, pixel size was 10 cm. The study involved the analysis of imagery acquired on 5 March 1998 for the detection of anomalous reflectance values and for the definition of spectral signatures as indicators of tree vigor and treatment effectiveness (e.g., drip irrigation; fertilizer application).

  9. High precision stress measurements in semiconductor structures by Raman microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Uhlig, Benjamin

    2009-07-01

    Stress in silicon structures plays an essential role in modern semiconductor technology. This stress has to be measured and due to the ongoing miniaturization in today's semiconductor industry, the measuring method has to meet certain requirements. The present thesis deals with the question how Raman spectroscopy can be used to measure the state of stress in semiconductor structures. In the first chapter the relation between Raman peakshift and stress in the material is explained. It is shown that detailed stress maps with a spatial resolution close to the diffraction limit can be obtained in structured semiconductor samples. Furthermore a novel procedure, the so called Stokes-AntiStokes-Difference method is introduced. With this method, topography, tool or drift effects can be distinguished from stress related influences in the sample. In the next chapter Tip-enhanced Raman Scattering (TERS) and its application for an improvement in lateral resolution is discussed. For this, a study is presented, which shows the influence of metal particles on the intensity and localization of the Raman signal. A method to attach metal particles to scannable tips is successfully applied. First TERS scans are shown and their impact on and challenges for high resolution stress measurements on semiconductor structures is explained. (orig.)

  10. A research of a high precision multichannel data acquisition system

    Science.gov (United States)

    Zhong, Ling-na; Tang, Xiao-ping; Yan, Wei

    2013-08-01

    The output signals of the focusing system in lithography are analog. To convert the analog signals into digital ones which are more flexible and stable to process, a desirable data acquisition system is required. The resolution of data acquisition, to some extent, affects the accuracy of focusing. In this article, we first compared performance between the various kinds of analog-to-digital converters (ADC) available on the market at the moment. Combined with the specific requirements (sampling frequency, converting accuracy, numbers of channels etc) and the characteristics (polarization, amplitude range etc) of the analog signals, the model of the ADC to be used as the core chip in our hardware design was determined. On this basis, we chose other chips needed in the hardware circuit that would well match with ADC, then the overall hardware design was obtained. Validation of our data acquisition system was verified through experiments and it can be demonstrated that the system can effectively realize the high resolution conversion of the multi-channel analog signals and give the accurate focusing information in lithography.

  11. High Precision Cosmology with the Cosmic Background Radiation

    Science.gov (United States)

    Farhang, Marzieh

    around the fiducial model of the standard recombination scenario. Though theoretically well studied, the detailed assumptions in the recombination history, based on standard atomic physics, have never been directly tested. However, for our CMB-based cosmological inferences to be reliable, the recombination scenario needs to be observationally verified. We approach this problem in a model-independent way and construct rank-ordered parameter eigen-modes with the highest power to probe Xe. We study various properties of these modes, including their convergence, fiducial model-dependence, dataset dependence, and the eigen-modes response to marginalization over different standard parameters. We demonstrate that, if enough modes are included, the eigen-modes form a practically complete set of basis function for expanding different physically motivated Xe perturbations. We also develop an information-based criterion to truncate the eigen-mode hierarchy, which can be used in similar hierarchical model selections as well. We show how our measurements of cosmic parameters will be affected if possible deviations in the recombination history are ignored. The method is applied to simulations of Planck+ACTPol and a cosmic variance limited survey with differing simulated recombination histories and the recovered Xe trajectories are constructed. We also apply the method to the best currently available CMB datasets, WMAP9+ACT/SPT. The first constructed eigen-mode turns out to be a direct measure of the damping envelope. Its current measurement with SPT slightly indicates a damping tail anomaly, while ACT data agree well with the standard scenario. High resolution Planck data will resolve this tension with high significance.

  12. Axial Halbach Magnetic Bearings

    Science.gov (United States)

    Eichenberg, Dennis J.; Gallo, Christopher A.; Thompson, William K.

    2008-01-01

    Axial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly reliable noncontact bearings for future high-speed rotary machines that may be used in such applications as aircraft, industrial, and land-vehicle power systems and in some medical and scientific instrumentation systems. Axial Halbach magnetic bearings are passive in the sense that unlike most other magnetic bearings that have been developed in recent years, they effect stable magnetic levitation without need for complex active control.

  13. Spectral Unmixing Plate Reader: High-Throughput, High-Precision FRET Assays in Living Cells.

    Science.gov (United States)

    Schaaf, Tory M; Peterson, Kurt C; Grant, Benjamin D; Thomas, David D; Gillispie, Gregory D

    2017-03-01

    We have developed a microplate reader that records a complete high-quality fluorescence emission spectrum on a well-by-well basis under true high-throughput screening (HTS) conditions. The read time for an entire 384-well plate is less than 3 min. This instrument is particularly well suited for assays based on fluorescence resonance energy transfer (FRET). Intramolecular protein biosensors with genetically encoded green fluorescent protein (GFP) donor and red fluorescent protein (RFP) acceptor tags at positions sensitive to structural changes were stably expressed and studied in living HEK cells. Accurate quantitation of FRET was achieved by decomposing each observed spectrum into a linear combination of four component (basis) spectra (GFP emission, RFP emission, water Raman, and cell autofluorescence). Excitation and detection are both conducted from the top, allowing for thermoelectric control of the sample temperature from below. This spectral unmixing plate reader (SUPR) delivers an unprecedented combination of speed, precision, and accuracy for studying ensemble-averaged FRET in living cells. It complements our previously reported fluorescence lifetime plate reader, which offers the feature of resolving multiple FRET populations within the ensemble. The combination of these two direct waveform-recording technologies greatly enhances the precision and information content for HTS in drug discovery.

  14. Single Crystal Piezomotor for Large Stroke, High Precision and Cryogenic Actuations Project

    Data.gov (United States)

    National Aeronautics and Space Administration — TRS Technologies proposes a novel single crystal piezomotor for large stroke, high precision, and cryogenic actuations with capability of position set-hold with...

  15. The High Precision Vibration Signal Data Acquisition System Based on the STM32

    National Research Council Canada - National Science Library

    Zhu Hui-Ling; Zhu Xin-Yin

    2014-01-01

    ... changes in cable resistance. Therefore, this paper proposed a high precision vibration signal acquisition with storage function based on STM32 microcontroller in order to promote safety in engineering construction...

  16. Development of precision numerical controlled high vacuum electron beam welding machine

    CERN Document Server

    Li Shao Lin

    2002-01-01

    The structure, main technical parameters and characteristics of the precision numerical controlled high vacuum electron beam welding machine are introduced. The design principle, some features and solutions to some key technique problems of this new type machine are described

  17. Development of a High Power Programmable Precise Time-Delay Trigger/Ignition System for MFCG

    Institute of Scientific and Technical Information of China (English)

    WU Bi; HE Yuan-hang; ZHANG Qing-ming; MA Yue-fen

    2008-01-01

    High-power precise delay trigger/ignition system is a programmable pulse generator developed for experiment controlling in explosively driven magnetic flux compression generators.Precise delay pulses are generated by the digital circuit,after being magnified and sharpened through multistage isolated amplifiers and rising edge sharpening device,high-voltage steep delay pulses with precision less than us level are obtained.This system has been used in our compact magnetic flux compression generator experiments in place of the traditional primaeord delay device.

  18. High Precision Prediction of Rolling Force Based on Fuzzy and Nerve Method for Cold Tandem Mill

    Institute of Scientific and Technical Information of China (English)

    JIA Chun-yu; SHAN Xiu-ying; NIU Zhao-ping

    2008-01-01

    The rolling force model for cold tandem mill was put forward by using the Elman dynamic recursive network method, based on the actual measured data. Furthermore, a good assumption is put forward, which brings a full universe of discourse self-adjusting factor fuzzy control, closed-loop adjusting, based on error feedback and expertise into a rolling force prediction model, to modify prediction outputs and improve prediction precision and robustness. The simulated results indicate that the method is highly effective and the prediction precision is better than that of the traditional method. Predicted relative error is less than ±4%, so the prediction is high precise for the cold tandem mill.

  19. Study of the data taking strategy for a high precision τ mass measurement

    Institute of Scientific and Technical Information of China (English)

    WANG You-Kai; ZHANG Jian-Yong; MO Xiao-Hu; YUAN Chang-Zheng

    2009-01-01

    To achieve a high precision τ mass measurement at the high luminosity experiment BESⅢ, Monte Carlo simulation and sampling technique are utilized to simulate various data taking cases for single and multi-parameter fits by virtue of which the optimal scheme is determined. The optimized proportion of luminosity distributed at selected points and the relation between precision and luminosity are obtained. In addition, the optimization of the fit scheme is confirmed by scrutinizing a variety of fit possibilities.

  20. Charge Breeding Techniques in an Electron Beam Ion Trap for High Precision Mass Spectrometry at TITAN

    Science.gov (United States)

    MacDonald, T. D.; Simon, M. C.; Bale, J. C.; Chowdhury, U.; Eibach, M.; Gallant, A. T.; Lennarz, A.; Simon, V. V.; Chaudhuri, A.; Grossheim, A.; Kwiatkowski, A. A.; Schultz, B. E.; Dilling, J.

    2012-10-01

    Penning trap mass spectrometry is the most accurate and precise method available for performing atomic mass measurements. TRIUMF's Ion Trap for Atomic and Nuclear science is currently the only facility to couple its Penning trap to a rare isotope facility and an electron beam ion trap (EBIT). The EBIT is a valuable tool for beam preparation: since the precision scales linearly with the charge state, it takes advantage of the precision gained by using highly charged ions. However, this precision gain is contingent on fast and efficient charge breeding. An optimization algorithm has been developed to identify the optimal conditions for running the EBIT. Taking only the mass number and half-life of the isotope of interest as inputs, the electron beam current density, charge breeding time, charge state, and electron beam energy are all specified to maximize this precision. An overview of the TITAN charge breeding program, and the results of charge breeding simulations will be presented.

  1. Burn-Up Determination by High Resolution Gamma Spectrometry: Axial and Diametral Scanning Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, R.S.; Blackadder, W.H.; Ronqvist, N.

    1967-02-15

    In the gamma spectrometric determination of burn-up the use of a single fission product as a monitor of the specimen fission rate is subject to errors caused by activity saturation or, in certain cases, fission product migration. Results are presented of experiments in which all the resolvable gamma peaks in the fission product spectrum have been used to calculate the fission rate; these results form a pattern which reflect errors in the literature values of the gamma branching ratios, fission yields etc., and also represent a series of empirical correction factors. Axial and diametral scanning experiments on a long-irradiated low-enrichment fuel element are also described and demonstrate that it is possible to differentiate between fissions in U-235 and in Pu-239 respectively by means of the ratios of the Ru-106 activity to the activities of the other fission products.

  2. CLASSIFICATION OF LIDAR DATA FOR GENERATING A HIGH-PRECISION ROADWAY MAP

    Directory of Open Access Journals (Sweden)

    J. Jeong

    2016-06-01

    Full Text Available Generating of a highly precise map grows up with development of autonomous driving vehicles. The highly precise map includes a precision of centimetres level unlike an existing commercial map with the precision of meters level. It is important to understand road environments and make a decision for autonomous driving since a robust localization is one of the critical challenges for the autonomous driving car. The one of source data is from a Lidar because it provides highly dense point cloud data with three dimensional position, intensities and ranges from the sensor to target. In this paper, we focus on how to segment point cloud data from a Lidar on a vehicle and classify objects on the road for the highly precise map. In particular, we propose the combination with a feature descriptor and a classification algorithm in machine learning. Objects can be distinguish by geometrical features based on a surface normal of each point. To achieve correct classification using limited point cloud data sets, a Support Vector Machine algorithm in machine learning are used. Final step is to evaluate accuracies of obtained results by comparing them to reference data The results show sufficient accuracy and it will be utilized to generate a highly precise road map.

  3. Classification of LIDAR Data for Generating a High-Precision Roadway Map

    Science.gov (United States)

    Jeong, J.; Lee, I.

    2016-06-01

    Generating of a highly precise map grows up with development of autonomous driving vehicles. The highly precise map includes a precision of centimetres level unlike an existing commercial map with the precision of meters level. It is important to understand road environments and make a decision for autonomous driving since a robust localization is one of the critical challenges for the autonomous driving car. The one of source data is from a Lidar because it provides highly dense point cloud data with three dimensional position, intensities and ranges from the sensor to target. In this paper, we focus on how to segment point cloud data from a Lidar on a vehicle and classify objects on the road for the highly precise map. In particular, we propose the combination with a feature descriptor and a classification algorithm in machine learning. Objects can be distinguish by geometrical features based on a surface normal of each point. To achieve correct classification using limited point cloud data sets, a Support Vector Machine algorithm in machine learning are used. Final step is to evaluate accuracies of obtained results by comparing them to reference data The results show sufficient accuracy and it will be utilized to generate a highly precise road map.

  4. Axial and transverse stress-strain characterization of the EU dipole high current density Nb{sub 3}Sn strand

    Energy Technology Data Exchange (ETDEWEB)

    Nijhuis, A; Ilyin, Y; Abbas, W [Faculty of Science and Technology, Low Temperature Division, University of Twente, PO Box 217, 7500 AE Enschede (Netherlands)], E-mail: a.nijhuis@tnw.utwente.nl

    2008-06-15

    We have measured the critical current (I{sub c}) of a high current density Nb{sub 3}Sn strand subjected to spatial periodic bending, periodic contact stress and uniaxial strain. The strand is destined for the cable-in-conduit conductors (CICC) of the European dipole (EDIPO) 12.5 T superconducting magnet test facility. The spatial periodic bending was applied on the strand, using the bending wavelengths from 5 to 10 mm with a peak bending strain of 1.5%, a periodic contact stress with a periodicity of 4.7 mm and a stress level exceeding 250 MPa. For the uniaxial strain characterization, the voltage-current characteristics were measured with an applied axial strain from -0.9% to +0.3%, with a magnetic field from 6 to 14 T, temperature from 4.2 to 10 K and currents up to almost 900 A. In addition the axial stiffness was determined by a tensile axial stress-strain test. The characterization of the strand is essential for understanding the behaviour of the strand under mainly axial thermal stress variation during cool down and transverse electromagnetic forces during charging, which is essential for the design of the CICC for the dipole magnet. The strand appears to be fully reversible in the compressive regime during the axial strain testing, while in the tensile regime, the behaviour is already irreversibly degraded when reaching the maximum in the critical current versus strain characteristic. The degradation is accentuated by an immediate decrease of the n value by a factor of 2. The parameters for the improved deviatoric strain description are derived from the I{sub c} data, giving the accuracy of the scaling with a standard deviation of 4 A, which is by far within the expected deviation for the large scale strand production of such a high J{sub c} strand. The I{sub c} versus the applied bending strain follows the low resistivity limit, indicative of full interfilament current transfer, while a strong decrease is observed at a peak bending strain of {approx}0

  5. Proposed design for high precision refractive index sensor using integrated planar lightwave circuit

    Science.gov (United States)

    Maru, Koichi; Fujii, Yusaku; Zhang, Shulian; Hou, Wenmei

    2009-07-01

    A high precision and compact refractive index sensor is proposed. The combination of coarse measurement utilizing the change of the angle of refraction and fine measurement utilizing the phase change is newly proposed to measure absolute refractive index precisely. The proposed method does not need expensive optical measurement equipment such as an optical spectrum analyzer. The integrated planar lightwave circuit (PLC) technology enables us to obtain a compact sensor that is preferable for the practical use. The principle, design, and some configurations for precise refractive index measurement are described.

  6. MRPC-PET: A new technique for high precision time and position measurements

    Energy Technology Data Exchange (ETDEWEB)

    Doroud, K., E-mail: kdoroud@cern.ch [World Laboratory, Geneva (Switzerland); Hatzifotiadou, D. [Sezione INFN, Bologna (Italy); Li, S. [World Laboratory, Geneva (Switzerland); Williams, M.C.S. [Sezione INFN, Bologna (Italy); Zichichi, A. [Dipartimento di Fisica dell' Universita, Bologna (Italy); PH Dept, CERN, Geneva (Switzerland); Zuyeuski, R. [World Laboratory, Geneva (Switzerland)

    2011-12-21

    The purpose of this paper is to consider a new technology for medical diagnosis: the MRPC-PET. This technology allows excellent time resolution together with 2-D position information thus providing a fundamental step in this field. The principle of this method is based on the Multigap Resistive Plate Chamber (MRPC) capable of high precision time measurements. We have previously found that the route to precise timing is differential readout (this requires matching anode and cathode strips); thus crossed strip readout schemes traditionally used for 2-D readout cannot be exploited. In this paper we consider the time difference from the two ends of the strip to provide a high precision measurement along the strip; the average time gives precise timing. The MRPC-PET thus provides a basic step in the field of medical technology: excellent time resolution together with 2-D position measurement.

  7. A High-Precision Registration Technology Based on Bundle Adjustment in Structured Light Scanning System

    Directory of Open Access Journals (Sweden)

    Jianying Yuan

    2014-01-01

    Full Text Available The multiview 3D data registration precision will decrease with the increasing number of registrations when measuring a large scale object using structured light scanning. In this paper, we propose a high-precision registration method based on multiple view geometry theory in order to solve this problem. First, a multiview network is constructed during the scanning process. The bundle adjustment method from digital close range photogrammetry is used to optimize the multiview network to obtain high-precision global control points. After that, the 3D data under each local coordinate of each scan are registered with the global control points. The method overcomes the error accumulation in the traditional registration process and reduces the time consumption of the following 3D data global optimization. The multiview 3D scan registration precision and efficiency are increased. Experiments verify the effectiveness of the proposed algorithm.

  8. Echo-planar magnetic resonance imaging (EPI) with high-resolution matrix in intra-axial brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Bruening, R.; Scheidler, J.; Porn, U.; Reiser, M. [Institute of Diagnostic Radiology, Klinikum Grosshadern, University of Munich (Germany); Seelos, K.; Yousry, T. [Department of Neuroradiology, Institute of Diagnostic Radiology, Klinikum Grosshadern, University of Munich (Germany); Exner, H. [Institute for Medical Epidemiology, Klinikum Grosshadern, University of Munich, Munich (Germany); Rosen, B.R. [Department of Radiology, Massachusetts General Hospital, NMR Center, Charlestown, MA (United States)

    1999-09-01

    The aim of this study was to assess the potential of high-speed interleaved echo-planar imaging (EPI) to achieve diagnostic image quality comparable to T2-weighted imaging in patients with brain tumors. Seventeen patients with intra-axial, supratentorial tumors (10 untreated gliomas, 7 radiated gliomas) were investigated on a 1.5-T scanner. The conventional scan (SE, TR/TE = 2200/80 ms, 18 slices) was acquired in 8 min, 4 s, and EPI (TR/TE = 3000/80 ms, 18 slices) was completed in 25 s. The films were compared in a blinded trail by three radiologists. On the general impression and anatomic display, both sequences were rated to be of similar quality. Artifacts were slightly more pronounced at the skull base and around surgical clips using EPI. Tumor delineation was nearly equivalent using EPI, compared with the T2-weighted sequence. Echo-planar imaging reached diagnostic quality in all patients. Interleaved high-resolution EPI yielded sufficient quality to depict intra-axial, supratentorial brain tumors. Since EPI can be obtained in a small fraction of the time needed for conventional spin echo, in addition to other indications it could be considered to study patients unable to cooperate. (orig.) With 3 figs., 3 tabs., 27 refs.

  9. Multiscale Multisensor Data Fusion and Application in High Precision Marking and Cutting Robot System

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The multisensor online measure system for high precision marking and cutting robot system is designed and the data fusion method is introduced, which combines augment state multiscale process with extend Kalman filter. The technology measuring the three-dimensional deforming information of profiled bars is applied. The experimental result shows that applying the multisensor data fusion technology can enhance the measure precision and the reliability of measure system.

  10. FOTOMCAp: a new quasi-automatic code for high-precision photometry

    CERN Document Server

    Petrucci, Romina

    2016-01-01

    The search for Earth-like planets using the transit technique has encouraged the development of strategies to obtain light curves with increasingly precision. In this context we developed the FOTOMCAp program. This is an IRAF quasi-automatic code which employs the aperture correction method and allows to obtain high-precision light curves. In this contribution we describe how this code works and show the results obtained for planetary transits light curves.

  11. FOTOMCAp: a new quasi-automatic code for high-precision photometry

    Science.gov (United States)

    Petrucci, R.; Jofré, J. E.

    2016-08-01

    The search for Earth-like planets using the transit technique has encouraged the development of strategies to obtain light curves with increasing precision. In this context we developed the fotomcap program. This is an iraf quasi-automatic code which employs the aperture correction method and allows to obtain high-precision light curves. In this contribution we describe how this code works and show the results obtained for planetary transits light curves.

  12. Use of Terrestrial Laser Scanning Technology for Long Term High Precision Deformation Monitoring

    Science.gov (United States)

    Vezočnik, Rok; Ambrožič, Tomaž; Sterle, Oskar; Bilban, Gregor; Pfeifer, Norbert; Stopar, Bojan

    2009-01-01

    The paper presents a new methodology for high precision monitoring of deformations with a long term perspective using terrestrial laser scanning technology. In order to solve the problem of a stable reference system and to assure the high quality of possible position changes of point clouds, scanning is integrated with two complementary surveying techniques, i.e., high quality static GNSS positioning and precise tacheometry. The case study object where the proposed methodology was tested is a high pressure underground pipeline situated in an area which is geologically unstable. PMID:22303152

  13. Performance of High-pressure-ratio Axial-flow Compressor Using Highly Cambered NACA 65-series Blower Blades at High Mach Numbers

    Science.gov (United States)

    Voit, Charles H; Guentert, Donald C; Dugan, James F

    1950-01-01

    A complete stage of an axial-flow compressor was designed and built to investigate the possibility of obtaining a high pressure ratio with an acceptable efficiency through the use of the optimum combination of high blade loading and high relative inlet Mach number. Over-all stage performance was investigated over a range of flows at equivalent tip speeds of 418 to 836 feet per second. At design speed (836 ft/sec), a peak total-pressure ration of 1.445 was obtained with an adiabatic efficiency of 0.89. For design angle of attack at the mean radius, a total-pressure ratio of 1.392 was obtained.

  14. High-precision Thickness Setting Models for Titanium Alloy Plate Cold Rolling without Tension

    Institute of Scientific and Technical Information of China (English)

    WANG Xiaochen; YANG Quan; HE Fei; SUN Youzhao; XIAO Huifang

    2015-01-01

    Due to its highly favorable physical and chemical properties, titanium and titanium alloy are widely used in a variety of industries. Because of the low output of a single batch, plate cold rolling without tension is the most common rolling production method for titanium alloy. This method is lack of on-line thickness closed-loop control, with carefully thickness setting models for precision. A set of high-precision thickness setting models are proposed to suit the production method. Because of frequent variations in rolling specification, a model structural for the combination of analytical models and statistical models is adopted to replace the traditional self-learning method. The deformation resistance and friction factor, the primary factors which affect model precision, are considered as the objectives of statistical modeling. Firstly, the coefficient fitting of deformation resistance analytical model based on over-determined equations set is adopted. Additionally, a support vector machine(SVM) is applied to the modeling of the deformation resistance and friction factor. The setting models are applied to a 1450 plate-coiling mill for titanium alloy plate rolling, and then thickness precision is found consistently to be within 3%, exceeding the precision of traditional setting models with a self-learning method based on a large number of stable rolling data. Excellent application performance is obtained. The proposed research provides a set of high-precision thickness setting models which are well adapted to the characteristics of titanium alloy plate cold rolling without tension.

  15. High-precision thickness setting models for titanium alloy plate cold rolling without tension

    Science.gov (United States)

    Wang, Xiaochen; Yang, Quan; He, Fei; Sun, Youzhao; Xiao, Huifang

    2015-03-01

    Due to its highly favorable physical and chemical properties, titanium and titanium alloy are widely used in a variety of industries. Because of the low output of a single batch, plate cold rolling without tension is the most common rolling production method for titanium alloy. This method is lack of on-line thickness closed-loop control, with carefully thickness setting models for precision. A set of high-precision thickness setting models are proposed to suit the production method. Because of frequent variations in rolling specification, a model structural for the combination of analytical models and statistical models is adopted to replace the traditional self-learning method. The deformation resistance and friction factor, the primary factors which affect model precision, are considered as the objectives of statistical modeling. Firstly, the coefficient fitting of deformation resistance analytical model based on over-determined equations set is adopted. Additionally, a support vector machine(SVM) is applied to the modeling of the deformation resistance and friction factor. The setting models are applied to a 1450 plate-coiling mill for titanium alloy plate rolling, and then thickness precision is found consistently to be within 3%, exceeding the precision of traditional setting models with a self-learning method based on a large number of stable rolling data. Excellent application performance is obtained. The proposed research provides a set of high-precision thickness setting models which are well adapted to the characteristics of titanium alloy plate cold rolling without tension.

  16. Design and algorithm research of high precision airborne infrared touch screen

    Science.gov (United States)

    Zhang, Xiao-Bing; Wang, Shuang-Jie; Fu, Yan; Chen, Zhao-Quan

    2016-10-01

    There are shortcomings of low precision, touch shaking, and sharp decrease of touch precision when emitting and receiving tubes are failure in the infrared touch screen. A high precision positioning algorithm based on extended axis is proposed to solve these problems. First, the unimpeded state of the beam between emitting and receiving tubes is recorded as 0, while the impeded state is recorded as 1. Then, the method of oblique scan is used, in which the light of one emitting tube is used for five receiving tubes. The impeded information of all emitting and receiving tubes is collected as matrix. Finally, according to the method of arithmetic average, the position of the touch object is calculated. The extended axis positioning algorithm is characteristic of high precision in case of failure of individual infrared tube and affects slightly the precision. The experimental result shows that the 90% display area of the touch error is less than 0.25D, where D is the distance between adjacent emitting tubes. The conclusion is gained that the algorithm based on extended axis has advantages of high precision, little impact when individual infrared tube is failure, and using easily.

  17. Axial Ligand Effects on the Structures of Self-Assembled Gallium-Porphyrin Monolayers on Highly Oriented Pyrolytic Graphite.

    Science.gov (United States)

    Kamm, Judith M; Iverson, Cameron P; Lau, Wing-Yeung; Hopkins, Michael D

    2016-01-19

    Monolayers of five-coordinate gallium octaethylporphyrin complexes (Ga(OEP)X; X = Cl, Br, I, O3SCF3, CCPh) on highly oriented pyrolytic graphite were studied at the solid-liquid (1-phenyloctane) interface using scanning tunneling microscopy (STM) to probe the dependence of their properties on the nature of the axial X ligand. Density functional theory calculations of the gas-phase structures of the free molecules reveal that the gallium atom is positioned above the plane of the porphyrin macrocycle, with this pyramidal distortion increasing in magnitude according to X = O3SCF3 (displacement = 0.35 Å) monolayers are sensitive to the nature of the axial ligand: the monolayers of Ga(OEP)(O3SCF3) and Ga(OEP)(CCPh) exhibit damage during the STM experiment upon repeated scanning and upon toggling the sign of the bias potential, but monolayers of Ga(OEP)Cl, Ga(OEP)Br, and Ga(OEP)I do not. A second important ligand-influenced property is that Ga(OEP)I forms bilayer structures, whereas the other Ga(OEP)X compounds form monolayers exclusively under identical conditions. The top layer of the Ga(OEP)I bilayer is oriented with the iodo ligand directed away from the surface, like the bottom layer, but the molecules pack in a square, lower-density geometry. The comparatively large polarizability of the iodo ligand is suggested to be important in stabilizing the bilayer structure.

  18. High Precision Calculations of the Lennard-Jones Lattice Constants for Five Lattices

    Science.gov (United States)

    Stein, Matthew

    2017-01-01

    The total potential energy of a crystal as described by the Lennard-Jones (L-J) potential depends in part upon the calculation of lattice constants. Knowing these constants to high precision is useful for prediction of the lattice type and simulation of crystals such as rare-gas solids or germanium detectors, but reaching higher precision is computationally costly and challenging. Presented here is the extension of the precision of the lattice constants, Lp, up to 32 decimal digits, and in some cases corrections from previous publication. The Lp terms are given for 4 cubic, face-centered cubic, body-centered cubic, hexagonal-close-pack, and diamond lattices. This precision was obtained through the use of careful parallelization technique, exploitation of the symmetries of each lattice, and the ``onionization'' of the simulated crystal. The results of this computation, along with the tools and algorithm strategies to make this computation possible, are explained in detail graphically.

  19. High Throughput, High Precision Hot Testing Tool for HBLED Wafer Level Testing

    Energy Technology Data Exchange (ETDEWEB)

    Solarz, Richard [KLA-Tencor Corporation, Milpitas, CA (United States); McCord, Mark [KLA-Tencor Corporation, Milpitas, CA (United States)

    2015-12-31

    The Socrates research effort developed an in depth understanding and demonstrated in a prototype tool new precise methods for teh characterization of color characteristics and flux from individual LEDs for the production of uniform quality lighting. This effort was focused on improving the color quality and consistency of solid state lighting and potentially reducing characterization costs for all LED product types. The patented laser hot testing method was demonstrated to be far more accurate than all current state of the art color and flux characterization methods in use by the solid state lighting industry today. A seperately patented LED grouping method (statistical binning) was demonstrated to be a useful approach to improving utilization of entire lots of large color and flux distributions of manufactured LEDs for high quality color solid-state lighting. At the conclusion of the research in late 2015 the solid-state lighting industry was however generally satisfied with its existing production methods for high quality color products for the small segment of customers that demand it, albeit with added costs.

  20. High precision locating control system based on VCM for Talbot lithography

    Science.gov (United States)

    Yao, Jingwei; Zhao, Lixin; Deng, Qian; Hu, Song

    2016-10-01

    Aiming at the high precision and efficiency requirements of Z-direction locating in Talbot lithography, a control system based on Voice Coil Motor (VCM) was designed. In this paper, we built a math model of VCM and its moving characteristic was analyzed. A double-closed loop control strategy including position loop and current loop were accomplished. The current loop was implemented by driver, in order to achieve the rapid follow of the system current. The position loop was completed by the digital signal processor (DSP) and the position feedback was achieved by high precision linear scales. Feed forward control and position feedback Proportion Integration Differentiation (PID) control were applied in order to compensate for dynamic lag and improve the response speed of the system. And the high precision and efficiency of the system were verified by simulation and experiments. The results demonstrated that the performance of Z-direction gantry was obviously improved, having high precision, quick responses, strong real-time and easily to expend for higher precision.

  1. Optimizing Planning and Delivery of High-Precision Robotic Radiotherapy and Intensity-Modulated Proton Therapy

    NARCIS (Netherlands)

    S. van de Water (Steven)

    2015-01-01

    markdownabstract__Abstract__ High-precision robotic radiotherapy and intensity-modulated proton therapy (IMPT) are two relatively new radiotherapy techniques that particularly aim at a highly localized delivery of a curative dose to the tumor, while achieving excellent sparing of the surrounding

  2. Optimizing Planning and Delivery of High-Precision Robotic Radiotherapy and Intensity-Modulated Proton Therapy

    NARCIS (Netherlands)

    S. van de Water (Steven)

    2015-01-01

    markdownabstract__Abstract__ High-precision robotic radiotherapy and intensity-modulated proton therapy (IMPT) are two relatively new radiotherapy techniques that particularly aim at a highly localized delivery of a curative dose to the tumor, while achieving excellent sparing of the surrounding he

  3. High-Precision Mass Measurements of Exotic Nuclei with the Triple-Trap Mass Spectrometer Isoltrap

    CERN Multimedia

    Blaum, K; Zuber, K T; Stanja, J

    2002-01-01

    The masses of close to 200 short-lived nuclides have already been measured with the mass spectrometer ISOLTRAP with a relative precision between 1$\\times$10$^{-7}$ and 1$\\times$10^{-8}$. The installatin of a radio-frequency quadrupole trap increased the overall efficiency by two orders of magnitude which is at present about 1%. In a recent upgrade, we installed a carbon cluster laser ion source, which will allow us to use carbon clusters as mass references for absolute mass measurements. Due to these improvements and the high reliability of ISOLTRAP we are now able to perform accurate high-precision mass measurements all over the nuclear chart. We propose therefore mass measurements on light, medium and heavy nuclides on both sides of the valley of stability in the coming four years. ISOLTRAP is presently the only instrument capable of the high precision required for many of the proposed studies.

  4. Precision of FLEET Velocimetry Using High-speed CMOS Camera Systems

    Science.gov (United States)

    Peters, Christopher J.; Danehy, Paul M.; Bathel, Brett F.; Jiang, Naibo; Calvert, Nathan D.; Miles, Richard B.

    2015-01-01

    Femtosecond laser electronic excitation tagging (FLEET) is an optical measurement technique that permits quantitative velocimetry of unseeded air or nitrogen using a single laser and a single camera. In this paper, we seek to determine the fundamental precision of the FLEET technique using high-speed complementary metal-oxide semiconductor (CMOS) cameras. Also, we compare the performance of several different high-speed CMOS camera systems for acquiring FLEET velocimetry data in air and nitrogen free-jet flows. The precision was defined as the standard deviation of a set of several hundred single-shot velocity measurements. Methods of enhancing the precision of the measurement were explored such as digital binning (similar in concept to on-sensor binning, but done in post-processing), row-wise digital binning of the signal in adjacent pixels and increasing the time delay between successive exposures. These techniques generally improved precision; however, binning provided the greatest improvement to the un-intensified camera systems which had low signal-to-noise ratio. When binning row-wise by 8 pixels (about the thickness of the tagged region) and using an inter-frame delay of 65 micro sec, precisions of 0.5 m/s in air and 0.2 m/s in nitrogen were achieved. The camera comparison included a pco.dimax HD, a LaVision Imager scientific CMOS (sCMOS) and a Photron FASTCAM SA-X2, along with a two-stage LaVision High Speed IRO intensifier. Excluding the LaVision Imager sCMOS, the cameras were tested with and without intensification and with both short and long inter-frame delays. Use of intensification and longer inter-frame delay generally improved precision. Overall, the Photron FASTCAM SA-X2 exhibited the best performance in terms of greatest precision and highest signal-to-noise ratio primarily because it had the largest pixels.

  5. Challenges in mold manufacturing for high precision molded diffractive optical elements

    Science.gov (United States)

    Pongs, Guido; Bresseler, Bernd; Schweizer, Klaus; Bergs, Thomas

    2016-09-01

    Isothermal precision glass molding of imaging optics is the key technology for mass production of precise optical elements. Especially for numerous consumer applications (e.g. digital cameras, smart phones, …), high precision glass molding is applied for the manufacturing of aspherical lenses. The usage of diffractive optical elements (DOEs) can help to further reduce the number of lenses in the optical systems which will lead to a reduced weight of hand-held optical devices. But today the application of molded glass DOEs is limited due to the technological challenges in structuring the mold surfaces. Depending on the application submicrometer structures are required on the mold surface. Furthermore these structures have to be replicated very precisely to the glass lens surface. Especially the micro structuring of hard and brittle mold materials such as Tungsten Carbide is very difficult and not established. Thus a multitude of innovative approaches using diffractive optical elements cannot be realized. Aixtooling has investigated in different mold materials and different suitable machining technologies for the micro- and sub-micrometer structuring of mold surfaces. The focus of the work lays on ultra-precision grinding to generate the diffractive pattern on the mold surfaces. This paper presents the latest achievements in diffractive structuring of Tungsten Carbide mold surfaces by ultra-precision grinding.

  6. Studies on fast timing and high precision tracking performance of Resistive Plate Chamber

    CERN Document Server

    Han, L; The ATLAS collaboration

    2013-01-01

    Resistive plate chambers (RPC), produced in large scales, are widely used as trigger detectors with O(ns) time resolution in high energy and high intensity experiments. To confront the future high experimental frontiers, such as the super-LHC, RPCs equipped with fine-pitch readout strips were tested with 180GeV/c muon at CERN SPS H8 beam line, to assess the viability of using RPCs for both fast timing and high precision tracking trigger.

  7. Towards high precision measurements of nuclear g-factors for the Be isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Takamine, A., E-mail: icot@riken.jp [RIKEN, Nishina Center for Accelerator Based Science, Wako City, Saitama (Japan); Wada, M. [RIKEN, Nishina Center for Accelerator Based Science, Wako City, Saitama (Japan); Okada, K. [Department of Physics, Sophia University, Chiyoda Ward, Tokyo (Japan); Ito, Y. [RIKEN, Nishina Center for Accelerator Based Science, Wako City, Saitama (Japan); Schury, P.; Arai, F. [RIKEN, Nishina Center for Accelerator Based Science, Wako City, Saitama (Japan); Institute of Physics, University of Tsukuba, Tsukuba City, Ibaraki (Japan); Katayama, I. [RIKEN, Nishina Center for Accelerator Based Science, Wako City, Saitama (Japan); Imamura, K. [RIKEN, Nishina Center for Accelerator Based Science, Wako City, Saitama (Japan); Department of Physics, Meiji University, Kawasaki City, Kanagawa (Japan); Ichikawa, Y.; Ueno, H. [RIKEN, Nishina Center for Accelerator Based Science, Wako City, Saitama (Japan); Wollnik, H. [Department of Chemistry and BioChemistry, New Mexico State University, Las Cruces, NM (United States); Schuessler, H.A. [Department of Physics, Texas A& M University, College Station, TX (United States)

    2016-06-01

    We describe the present status of future high-precision measurements of nuclear g-factors utilizing laser-microwave double and laser-microwave-rf triple resonance methods for online-trapped, laser-cooled radioactive beryllium isotope ions. These methods have applicability to other suitably chosen isotopes and for beryllium show promise in deducing the hyperfine anomaly of {sup 11}Be with a sufficiently high precision to study the nuclear magnetization distribution of this one-neutron halo nucleus in a nuclear-model-independent manner.

  8. Diamond turning of high-precision roll-to-roll imprinting molds for fabricating subwavelength gratings

    Science.gov (United States)

    Liu, Chun-Wei; Yan, Jiwang; Lin, Shih-Chieh

    2016-06-01

    Diamond turning of high-precision molds is a vital process for the roll-to-roll-based ultraviolet resin imprinting process in fabricating subwavelength gratings. The effects of the grating shape and grating period on diffraction efficiencies and diffraction angles were simulated. Experiments were then conducted to examine the effects of shape design, grating period, and cutting speed on machinability of the mold. According to the optical measurement results, the performance of the subwavelength gratings matched the design well at various incident angles. The results confirm that diamond turning of high-precision molds is a feasible approach for ensuring the continual mass production of subwavelength gratings.

  9. High-resolution AUV mapping of the 2015 flows at Axial Seamount, Juan de Fuca Ridge

    Science.gov (United States)

    Paduan, J. B.; Chadwick, W. W., Jr.; Clague, D. A.; Le Saout, M.; Caress, D. W.; Thomas, H. J.; Yoerger, D.

    2016-12-01

    Lava flows erupted in April 2015 at Axial Seamount were mapped at 1-m resolution with the AUV Sentry in August 2015 and the MBARI Mapping AUVs in July 2016 and observed and sampled with ROVs on those same expeditions. Thirty percent of terrain covered by new flows had been mapped by the MBARI AUVs prior to the eruption. Differencing of before and after maps (using ship-collected bathymetry where the AUV had not mapped before) allows calculation of extents and volumes of flows and shows new fissures. The maps reveal unexpected fissure patterns and shifts in the style of flow emplacement through a single eruption. There were 11 separate flows totaling 1.48 x 108 m3 of lava erupted from numerous en echelon fissures over 19 km on the NE caldera floor, on the NE flank, and down the N rift zone. Flows in and around the caldera have maximum thicknesses of 5-19 m. Most erupted as sheet flows and spread along intricate channels that terminated in thin margins. Some utilized pre-existing fissures. Some flows erupted from short fissures, while at least two longer new fissures produced little or no lava. A flow on the upper N rift has a spectacular lava channel flanked by narrow lava pillars supporting a thin roof left after the flow drained. A shatter ring still emanating warm fluid is visible in the map as a 15-m wide low cone. Hundreds of exploded pillows were observed but are not discernable in the bathymetry. The northern-most three flows deep on the N rift are similar in area to the others but comprise the bulk of the eruption volume. Differencing of ship-based bathymetry shows only these flows. Near the eruptive fissures they are sheet flows, but as they flowed downslope they built complexes of coalesced pillow mounds up to 67-128 m thick. Changes in flow morphology occurred through the course of the eruption. Large pillow mounds had molten cores that deformed as the eruption progressed. One flow began as a thin, effusive sheet flow but as the eruption rate decreased, a

  10. A high-precision calculation method for interface normal and curvature on an unstructured grid

    Science.gov (United States)

    Ito, Kei; Kunugi, Tomoaki; Ohno, Shuji; Kamide, Hideki; Ohshima, Hiroyuki

    2014-09-01

    In the volume-of-fluid algorithm, the calculations of the interface normal and curvature are crucially important for accurately simulating interfacial flows. However, few methods have been proposed for the high-precision interface calculation on an unstructured grid. In this paper, the authors develop a height function method that works appropriately on an unstructured grid. In the process, the definition of the height function is discussed, and the high-precision calculation method of the interface normal is developed to meet the necessary condition for a second-order method. This new method has highly reduced computational cost compared with a conventional high-precision method because the interface normal calculation is completed by solving relatively simple algebraic equations. The curvature calculation method is also discussed and the approximated quadric curve of an interface is employed to calculate the curvature. Following a basic verification, the developed height function method is shown to successfully provide superior calculation accuracy and highly reduced computational cost compared with conventional calculation methods in terms of the interface normal and curvature. In addition, the height function method succeeds in calculating accurately the slotted-disk revolution problem and the oscillating drop on unstructured grids. Therefore, the developed height function method is confirmed to be an efficient technique for the high-precision numerical simulation of interfacial flows on an unstructured grid.

  11. Super high precision 200 ppi liquid crystal display series; Chokoseido 200 ppi ekisho display series

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    In mobile equipment, in demand is a high precision liquid crystal display (LCD) having the power of expression equivalent to printed materials like magazines because of the necessity of displaying a large amount of information on a easily potable small screen. In addition, with the spread and high-quality image of digital still cameras, it is strongly desired to display photographed digital image data in high quality. Toshiba Corp., by low temperature polysilicone (p-Si) technology, commercialized the liquid crystal display series of 200 ppi (pixels per inch) precision dealing with the rise of the high-precision high-image quality LCD market. The super high precision of 200 ppi enables the display of smooth beautiful animation comparable to printed sheets of magazines and photographs. The display series are suitable for the display of various information services such as electronic books and electronic photo-viewers including internet. The screen sizes lined up are No. 4 type VGA (640x480 pixels) of a small pocket notebook size and No. 6.3 type XGA (1,024x768 pixels) of a paperback size, with a larger screen to be furthered. (translated by NEDO)

  12. Direct optical nanoscopy with axially localized detection

    Science.gov (United States)

    Bourg, N.; Mayet, C.; Dupuis, G.; Barroca, T.; Bon, P.; Lécart, S.; Fort, E.; Lévêque-Fort, S.

    2015-09-01

    Evanescent light excitation is widely used in super-resolution fluorescence microscopy to confine light and reduce background noise. Here, we propose a method of exploiting evanescent light in the context of emission. When a fluorophore is located in close proximity to a medium with a higher refractive index, its near-field component is converted into light that propagates beyond the critical angle. This so-called supercritical-angle fluorescence can be captured using a high-numerical-aperture objective and used to determine the axial position of the fluorophore with nanometre precision. We introduce a new technique for three-dimensional nanoscopy that combines direct stochastic optical reconstruction microscopy (dSTORM) with dedicated detection of supercritical-angle fluorescence emission. We demonstrate that our approach of direct optical nanoscopy with axially localized detection (DONALD) typically yields an isotropic three-dimensional localization precision of 20 nm within an axial range of ∼150 nm above the coverslip.

  13. Kinetic modeling of a high power fast-axial-flow CO2 laser with computational fluid dynamics method

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    A new computational fluid dynamics (CFD) method for the simulation of fast-axial-flow CO2 laser is developed.The model which is solved by CFD software uses a set of dynamic differential equations to describe the dynamic process in one discharge tube.The velocity,temperature,pressure and turbulence energy distributions in discharge passage are presented.There is a good agreement between the theoretical prediction and the experimental results.This result indicates that the parameters of the laser have significant effect on the flow distribution in the discharge passage.It is helpful to optimize the output of high power CO2 laser by mastering its kinetic characteristics.

  14. Characteristic and magnetic field analysis of a high temperature superconductor axial-flux coreless induction maglev motor

    Science.gov (United States)

    Wei, Qin; Yu, Fan; Jin, Fang; Shuo, Li; Guoguo, Li; Gang, Lv

    2012-04-01

    A new high temperature superconductor axial-flux coreless maglev motor (HTS AFIM) is proposed, of which the primary windings are made of HTS tapes and the secondary is a non-magnetic conductor. The main works of this paper are the magnetic-field computation and characteristics analysis of HTS AFIM. For the first one, the reduction of magnetic fields near outer and inner radius of the HTS AFIM is solved by introducing the sub-loop electro-magnetic model along the radial position. For the second one, the AC losses of HTS coils are calculated. The relationships between the device's characteristics and device parameters are presented, and the results indicate that under certain frequency and current levitation device can output enough lift force. The conclusions are verified by finite element calculations.

  15. Characteristic and magnetic field analysis of a high temperature superconductor axial-flux coreless induction maglev motor.

    Science.gov (United States)

    Wei, Qin; Yu, Fan; Jin, Fang; Shuo, Li; Guoguo, Li; Gang, Lv

    2012-04-01

    A new high temperature superconductor axial-flux coreless maglev motor (HTS AFIM) is proposed, of which the primary windings are made of HTS tapes and the secondary is a non-magnetic conductor. The main works of this paper are the magnetic-field computation and characteristics analysis of HTS AFIM. For the first one, the reduction of magnetic fields near outer and inner radius of the HTS AFIM is solved by introducing the sub-loop electro-magnetic model along the radial position. For the second one, the AC losses of HTS coils are calculated. The relationships between the device's characteristics and device parameters are presented, and the results indicate that under certain frequency and current levitation device can output enough lift force. The conclusions are verified by finite element calculations.

  16. High-Precision Floating-Point Arithmetic in ScientificComputation

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, David H.

    2004-12-31

    At the present time, IEEE 64-bit floating-point arithmetic is sufficiently accurate for most scientific applications. However, for a rapidly growing body of important scientific computing applications, a higher level of numeric precision is required: some of these applications require roughly twice this level; others require four times; while still others require hundreds or more digits to obtain numerically meaningful results. Such calculations have been facilitated by new high-precision software packages that include high-level language translation modules to minimize the conversion effort. These activities have yielded a number of interesting new scientific results in fields as diverse as quantum theory, climate modeling and experimental mathematics, a few of which are described in this article. Such developments suggest that in the future, the numeric precision used for a scientific computation may be as important to the program design as are the algorithms and data structures.

  17. HIGH-PRECISION POSITIONING AND REAL-TIME DATA PROCESSING OF UAV-SYSTEMS

    Directory of Open Access Journals (Sweden)

    M. Rieke

    2012-09-01

    Full Text Available Available micro-sized Unmanned Aerial Vehicles (UAVs in the civilian domain currently make use of common GPS receivers and do not address scenarios where high-precision positioning of the UAV is an inevitable requirement. However, for use cases such as creating orthophotos using direct georeferencing, an improved positioning needs to be developed. This article analyses the requirements for integrating Real Time Kinematic positioning into micro-sized UAVs. Additionally, it describes the data processing and synchronisation of the high-precision position data for a workflow of orthorectification of aerial imagery. Preliminary results are described for the use case of precision farming. The described approach for positioning has the potential to achieve a positional accuracy of 1–3 cm, which can be considered as adequate for direct georeferencing of aerial imagery.

  18. A high-precision K-band LFMCW radar for range measurement

    Science.gov (United States)

    Jia, Yingzhuo; Chen, Xiuwei; Zou, Yongliao

    2016-11-01

    K-band LFMCW radar may be applied in high-precision range measurement, if its range resolution is made be close to mm magnitude, good performance is not only needed in hardware design, algorithm selection and optimization is but also needed. In K-band LFMCW radar system, CZT algorithm is modified according to practical radar echo signal, its simulation model is built in the System Generator tool software, the corresponding algorithm is implemented in FPGA. K-band LFMCW radar may be applied in range measurement of great volume storage tank, the outfield experiment was done according to application, experiment result shows that range measurement precision may reach mm magnitude, the system can meet the requirement of remote high-precision measurement.

  19. High Precision Measurement of the differential W and Z boson cross-sections

    CERN Document Server

    Gasnikova, Ksenia; The ATLAS collaboration

    2017-01-01

    Measurements of the Drell-Yan production of W and Z/gamma bosons at the LHC provide a benchmark of our understanding of perturbative QCD and probe the proton structure in a unique way. The ATLAS collaboration has performed new high precision measurements at center-of-mass energies of 7. The measurements are performed for W+, W- and Z/gamma bosons integrated and as a function of the boson or lepton rapidity and the Z/gamma* mass. Unprecedented precision is reached and strong constraints on Parton Distribution functions, in particular the strange density are found. Z cross sections are also measured at a center-of-mass energies of 8TeV and 13TeV, and cross-section ratios to the top-quark pair production have been derived. This ratio measurement leads to a cancellation of several systematic effects and allows therefore for a high precision comparison to the theory predictions.

  20. High signal-to-noise ratio observations and the ultimate limits of precision pulsar timing

    CERN Document Server

    Oslowski, Stefan; Hobbs, George; Bailes, Matthew; Demorest, Paul

    2011-01-01

    We demonstrate that the sensitivity of high-precision pulsar timing experiments will be ultimately limited by the broadband intensity modulation that is intrinsic to the pulsar's stochastic radio signal. That is, as the peak flux of the pulsar approaches that of the system equivalent flux density, neither greater antenna gain nor increased instrumental bandwidth will improve timing precision. These conclusions proceed from an analysis of the covariance matrix used to characterise residual pulse profile fluctuations following the template matching procedure for arrival time estimation. We perform such an analysis on 25 hours of high-precision timing observations of the closest and brightest millisecond pulsar, PSR J0437-4715. In these data, the standard deviation of the post-fit arrival time residuals is approximately four times greater than that predicted by considering the system equivalent flux density, mean pulsar flux and the effective width of the pulsed emission. We develop a technique based on principa...

  1. High precision metrology method for unobscured Three Mirror Anastigmatic (TMA) mapping camera boresight

    Science.gov (United States)

    Zhao, Xi-ting; Jiao, Wen-chun; Liao, Zhi-bo

    2012-10-01

    High precision of mapping camera boresight directly affects the positioning accuracy of geographical location and photogrammetry. Although it can fulfill the request of good performance for unobscured TMA optical system, which adopted computer aided alignment method, single lens was unobscured which unable ascertain boresight by using lens centering technology, and boresight is randomicity as a result of compensating relation of multivariables. A novel method using the measurement of theodolite space intersection was proposed to rapidly and high accurately complete establish the relation between boresight and a cube in precision alignment stage, simultaneously, the relation of component deflexion and boresight have been simulated by computer model reverse optimization. Thus, the image quality and precision of boresight was effective operated according to the request of satellite assembly.

  2. A High-precision Motion Compensation Method for SAR Based on Image Intensity Optimization

    Directory of Open Access Journals (Sweden)

    Hu Ke-bin

    2015-02-01

    Full Text Available Owing to the platform instability and precision limitations of motion sensors, motion errors negatively affect the quality of synthetic aperture radar (SAR images. The autofocus Back Projection (BP algorithm based on the optimization of image sharpness compensates for motion errors through phase error estimation. This method can attain relatively good performance, while assuming the same phase error for all pixels, i.e., it ignores the spatial variance of motion errors. To overcome this drawback, a high-precision motion error compensation method is presented in this study. In the proposed method, the Antenna Phase Centers (APC are estimated via optimization using the criterion of maximum image intensity. Then, the estimated APCs are applied for BP imaging. Because the APC estimation equals the range history estimation for each pixel, high-precision phase compensation for every pixel can be achieved. Point-target simulations and processing of experimental data validate the effectiveness of the proposed method.

  3. Peculiarities of high-overtone transition probabilities in carbon monoxide revealed by high-precision calculation

    Energy Technology Data Exchange (ETDEWEB)

    Medvedev, Emile S., E-mail: esmedved@orc.ru [The Institute of Problems of Chemical Physics, Russian Academy of Sciences, Prospect Akademika Semenova 1, 142432 Chernogolovka (Russian Federation); Meshkov, Vladimir V.; Stolyarov, Andrey V. [Department of Chemistry, Lomonosov Moscow State University, Leninskie gory 1/3, 119991 Moscow (Russian Federation); Gordon, Iouli E. [Atomic and Molecular Physics Division, Harvard-Smithsonian Center for Astrophysics, 60 Garden St, Cambridge, Massachusetts 02138 (United States)

    2015-10-21

    In the recent work devoted to the calculation of the rovibrational line list of the CO molecule [G. Li et al., Astrophys. J., Suppl. Ser. 216, 15 (2015)], rigorous validation of the calculated parameters including intensities was carried out. In particular, the Normal Intensity Distribution Law (NIDL) [E. S. Medvedev, J. Chem. Phys. 137, 174307 (2012)] was employed for the validation purposes, and it was found that, in the original CO line list calculated for large changes of the vibrational quantum number up to Δn = 41, intensities with Δn > 11 were unphysical. Therefore, very high overtone transitions were removed from the published list in Li et al. Here, we show how this type of validation is carried out and prove that the quadruple precision is indispensably required to predict the reliable intensities using the conventional 32-bit computers. Based on these calculations, the NIDL is shown to hold up for the 0 → n transitions till the dissociation limit around n = 83, covering 45 orders of magnitude in the intensity. The low-intensity 0 → n transition predicted in the work of Medvedev [Determination of a new molecular constant for diatomic systems. Normal intensity distribution law for overtone spectra of diatomic and polyatomic molecules and anomalies in overtone absorption spectra of diatomic molecules, Institute of Chemical Physics, Russian Academy of Sciences, Chernogolovka, 1984] at n = 5 is confirmed, and two additional “abnormal” intensities are found at n = 14 and 23. Criteria for the appearance of such “anomalies” are formulated. The results could be useful to revise the high-overtone molecular transition probabilities provided in spectroscopic databases.

  4. Remote and high precision step height measurement with an optical fiber multiplexing interferometric system

    Science.gov (United States)

    Wang, Yunzhi; Xie, Fang; Ma, Sen; Chen, Liang

    2015-03-01

    An optical fiber multiplexing low coherence and high coherence interferometric system, which includes a Fizeau interferometer as the sensing element and a Michelson interferometer as the demodulating element, is designed for remote and high precision step height measurement. The Fizeau interferometer is placed in the remote field for sensing the measurand, while the Michelson interferometer which works in both modes of low coherence interferometry and high coherence interferometry is employed for demodulating the measurand. The range of the step height is determined by the low coherence interferometry and the value of it is measured precisely by the high coherence interferometry. High precision has been obtained by searching precisely the peak of the low coherence interferogram symmetrically from two sides of the low coherence interferogram and stabilizing the Michelson interferometer with a feedback loop. The maximum step height that could be measured is 6 mm while the measurement resolution is less than 1 nm. The standard deviation of 10 times measurement results of a step height of 1 mm configurated with two gauge blocks is 0.5 nm.

  5. High precision planar waveguide propagation loss measurement technique using a Fabry-Perot cavity

    DEFF Research Database (Denmark)

    Feuchter, Thomas; Thirstrup, Carsten

    1994-01-01

    A high precision measurement technique for characterizing the propagation loss in silica low-loss optical waveguides, based on measuring the contrast of a Fabry-Perot cavity, is demonstrated. The cavity consists of the waveguide coupled to two polarization-maintaining fibers, each end facet coated...

  6. High-precision photometry by telescope defocusing - VII. The ultrashort period planet WASP-103

    DEFF Research Database (Denmark)

    Southworth, John; Mancini, L.; Ciceri, S.

    2015-01-01

    We present 17 transit light curves of the ultra-short period planetary system WASP-103, a strong candidate for the detection of tidally-induced orbital decay. We use these to establish a high-precision reference epoch for transit timing studies. The time of the reference transit midpoint is now m...

  7. An optical fiber multiplexing interferometric system for measuring remote and high precision step height

    Science.gov (United States)

    Wang, Yunzhi; Xie, Fang; Ma, Sen; Chen, Liang

    2015-02-01

    In this paper, an optical fiber multiplexing interferometric system including a Fizeau interferometer and a Michelson interferometer is designed for remote and high precision step height measurement. The Fizeau interferometer which is inserted in the remote sensing field is used for sensing the measurand, while the Michelson interferometer which is stabilized by a feedback loop works in both modes of low coherence interferometry and high coherence interferometry to demodulate the measurand. The range of the step height is determined by the low coherence interferometry and the value of it is measured precisely by the high coherence interferometry. High precision has been obtained by using the symmetrical peak-searching method to address the peak of the low coherence interferogram precisely and stabilizing the Michelson interferometer with a feedback loop. The maximum step height that could be measured is 6 mm while the measurement resolution is less than 1 nm. The standard deviation of 10 times measurement results of a step height of 1 mm configurated with two gauge blocks is 0.5 nm.

  8. High-precision photometry by telescope defocusing - I. The transiting planetary system WASP-5

    DEFF Research Database (Denmark)

    Southworth, J.; Hinse, T. C.; Jørgensen, U. G.;

    2009-01-01

    We present high-precision photometry of two transit events of the extrasolar planetary system WASP-5, obtained with the Danish 1.54-m telescope at European Southern Obseratory La Silla. In order to minimize both random and flat-fielding errors, we defocused the telescope so its point spread...

  9. Analysis of Trace Hydrogen Isotopes in Fusion Fuel Cycle by High Precision Gas Chromatograph

    Institute of Scientific and Technical Information of China (English)

    YANG; Li-ling; YANG; Hong-guang; ZHAO; Wei-wei; HE; Chang-shui; LIU; Zhen-xing; ZHAN; Qin

    2013-01-01

    It is essential to analysis of hydrogen isotopes in the fuel cycle system of fusion reactors,gas chromatography(GC)was found to be an effectively analytical technique.Compared with conventional GC,the high-precision GC with a cryogenic column could achieve fairly good performance to reduce the retention time.

  10. High-precision spectroscopy of the HD+ molecule at the 1-p.p.b. level

    CERN Document Server

    Biesheuvel, J; Hilico, L; Eikema, K S E; Ubachs, W; Koelemeij, J C J

    2016-01-01

    Recently we reported a high precision optical frequency measurement of the (v,L):(0,2)->(8,3) vibrational overtone transition in trapped deuterated molecular hydrogen (HD+) ions at 10 mK temperature. Achieving a resolution of 0.85 parts-per-billion (p.p.b.) we found the experimental value ($\

  11. Early Bronze Jericho : High-precision C-14 dates of short-lived palaeobotanic remains

    NARCIS (Netherlands)

    Bruins, HJ; Van Der Plicht, J; Mook, W.G.

    1998-01-01

    Reliable series of high-precision radiocarbon dates in a stratified archaeological context are of great importance for interdisciplinary chronological and historical studies. The Early Bronze Age in the Near East is characterized by the beginning of the great civilizations in Egypt and Mesopotamia,

  12. Axial growth in high Zircaloy-4 structural components due to the hydrogen incorporation; Crecimiento axial de componentes de Zircaloy-4 debido a la incorporacion de hidrogeno

    Energy Technology Data Exchange (ETDEWEB)

    Fagundez, Cintia P.; Vizcaino, Pablo; Bianchi, Daniel; Banchik, Abraham D. [Comision Nacional de Energia Atomica (CNEA), Buenos Aires (Argentina). Centro Atomico Ezeiza. Lab. de Materiales Planta Piloto de Fabricacion de Aleaciones Especiales]. E-mail: fagundez@cnea.gov.ar; vizcaino@cae.cnea.gov.ar; banchik@cae.cnea.gov.ar; dbianchi@cae.cnea.gov.ar

    2005-07-01

    The zirconium based structural components under the severe operation conditions experiment changes in theirs original dimensions. These dimensional changes may be attributed to two causes: hydrogen incorporation and irradiation growth. Both causes play a role in the dimensional changes but only the reactor- in conditions can define if the two or one of them is significant. In structural components as the pressure tubes of the CANDU type reactors, where hydrogen content is less than forty ppm are acceptable, changes due to hydrogen incorporation are irrelevant. But in the case of the six meters long cooling channels of the Atucha 1 (CNA-1) nuclear power reactor, where hydrogen content up to 1000 ppm are possible, the situation could be different. In the present work the attention was focused on the volume changes due to the hydrogen incorporation. When the terminal solid solubility limit is exceeded in the zirconium based alloys, the hydride precipitation occurs. In Zircaloy-4 at the operating temperature, 300 deg C, about 90 ppm are in solid solution and the rest is precipitated as hydrides. Both situations produce a positive volume change which contributes to the growth. In this work the dimensional change produced by hydrogen incorporation in the CNA-1's channels was estimated. The expansion due to hydrogen absorption and the change of length caused by hydride dissolution and precipitation were measured by differential dilatometry in samples with hydrogen contents ranging from 20 to 650 ppm. The dilatometric data indicates that in the cooling channels of the CNA1, the axial growth is linear with the hydrogen concentration, and the calculated growing rate is 1,87 x 10-6 mm/mm material {sup *}ppm H. This rate for the upper hydrogen concentration limit of the channels implies a growth of 6,08 mm. As an accuracy testing method for the applied technique, the terminal solid solubility curve was determined by both, differential dilatometry and differential scanning

  13. Microplasma patterning of bonded microchannels using high-precision "injected" electrodes.

    Science.gov (United States)

    Priest, Craig; Gruner, Philipp J; Szili, Endre J; Al-Bataineh, Sameer A; Bradley, James W; Ralston, John; Steele, David A; Short, Robert D

    2011-02-07

    A rapid, high-precision method for localised plasma-treatment of bonded PDMS microchannels is demonstrated. Patterned electrodes were prepared by injection of molten gallium into preformed microchannel guides. The electrode guides were prepared without any additional fabrication steps compared to conventional microchannel fabrication. Alignment of the "injected" electrodes is precisely controlled by the photomask design, rather than positioning accuracy of alignment tools. Surface modification is detected using a fluorescent dye (Rhodamine B), revealing a well-defined micropattern with regions less than 100 µm along the length of the microchannel.

  14. Investigation of the proton-neutron interaction by high-precision nuclear mass measurements

    CERN Multimedia

    Savreux, R P; Akkus, B

    2007-01-01

    We propose to measure the atomic masses of a series of short-lived nuclides, including $^{70}$Ni, $^{122-130}$Cd, $^{134}$Sn, $^{138,140}$Xe, $^{207-210}$Hg, and $^{223-225}$Rn, that contribute to the investigation of the proton-neutron interaction and its role in nuclear structure. The high-precision mass measurements are planned for the Penning trap mass spectrometer ISOLTRAP that reaches the required precision of 10 keV in the nuclear mass determination.

  15. Characterization of precision of a handling system in high performance transfer press for micro forming

    DEFF Research Database (Denmark)

    Mahshid, Rasoul; Hansen, Hans Nørgaard; Arentoft, Mogens

    2014-01-01

    Multi-step micro bulk forming is characterized by complex processes and high precision requirements. In particular the demands regarding handling accuracy between different forming steps are of the order of a few mm. The paper introduces a methodology for the analysis and characterization...... of this transfer system on component level and system level. Laser interferometry is used in combination with analytical models to predict the positioning ability of the actuator in a static as well as dynamic mode. In combination with an analysis of the grippers, a full description of the transfer precision...

  16. High precision measurement of the differential $W$ and $Z$ boson production cross sections

    CERN Document Server

    Sommer, Philip; The ATLAS collaboration

    2017-01-01

    Measurements of the Drell-Yan production of $W$ and $Z/\\gamma^*$ bosons at the LHC provide a benchmark of our understanding of perturbative QCD and probe the proton structure in a unique way. The ATLAS collaboration has performed new high precision measurements at center-of-mass energies of 7 TeV. The measurements are performed for $W^+$, $W^-$ and $Z/\\gamma^*$ bosons integrated and as a function of the boson or lepton rapidity and the $Z/\\gamma^*$ mass. Unprecedented precision is reached and strong constraints on Parton Distribution functions, in particular the strange density are found. Slides for DIS 2017 in Birmingham

  17. Enabling ultra high precision on hard steels using surface defect machining

    OpenAIRE

    2014-01-01

    This paper is an extension to an idea coined during the 13th EUSPEN Conference (P6.23) named "surface defect machining" (SDM). The objective of this work was to demonstrate how a conventional CNC turret lathe can be used to obtain ultra high precision machined surface finish on hard steels without recourse to a sophisticated ultra precision machine tool. An AISI 4340 hard steel (69 HRC) workpiece was machined using a CBN cutting tool with and without SDM. Post-machining measurements by a Form...

  18. A faster, high precision algorithm for calculating symmetric and asymmetric $M_{T2}$

    CERN Document Server

    Lally, Colin H

    2015-01-01

    A new algorithm for calculating the stransverse mass, $M_{T2}$, in either symmetric or asymmetric situations has been developed which exhibits good stability, high precision and quadratic convergence for the majority of the $M_{T2}$ parameter space, leading to up to a factor of ten increase in speed compared to other $M_{T2}$ calculators of comparable precision. This document describes and validates the methodology used by the algorithm, and provides comparisons both in terms of accuracy and speed with other existing implementations.

  19. Development of high-performance and low-noise axial-flow fan units in their local operating region

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Seung; Ha, Min Ho; Cheong, Cheol Ung [Pusan National University, Busan (Korea, Republic of); Kim, Tae Hoon [LG Electronics Inc., Changwon (Korea, Republic of)

    2015-09-15

    Aerodynamic and aeroacoustic performances of an axial-flow fan unit are improved by modifying its housing structure without changing the fan blade. The target axial-flow fan system is used to lower temperature of a compressor and a condenser in the machine room of a household refrigerator which has relatively high system resistance due to complex layout of structures inside it. First, the performance of the fan system is experimentally characterized by measuring its volume flow rate versus static pressure using a fan performance tester satisfying the AMCA (Air Movement and Control Association) regulation, AMCA 210-07. The detailed structure of flow driven by the fan is numerically investigated using a virtual fan performance tester based on computational fluid dynamics techniques. The prediction result reveals possible loss due to radial and tangential velocity components in the wake flow downstream of the fan. The length of the fan housing is chosen as a design parameter for improving the aerodynamic and aeroacoustic performances of the fan unit by reducing the identified radial and tangential velocity components. Three fan units with different housing lengths longer than the original are analyzed using the virtual fan performance tester. The results confirm the improved aerodynamic performance of the proposed three designs. The flow field driven by the proposed fan unit is closely examined to find the causes for the observed performance improvements, which ensures that the radial and tangential velocity components in the wake flow are reduced. Finally, the improved performance of the proposed fan systems is validated by comparing the P-Q and efficiency curves measured using the fan performance tester. The noise emission from the household refrigerator is also found to be lessened when the new fan units are installed.

  20. A High Precision Direct Integration Scheme Based on Variational Principle and Its Applications

    Directory of Open Access Journals (Sweden)

    Zhu Shuai

    2016-01-01

    Full Text Available Dynamics response of systems to impact or loading may be effectively treated by direct integration. However, it is often difficult to select the time-step of integration properly, especially in the case which the system is badly stiff. High Precision Direct integration based on variational principle is given (HPD-VP for homogeneous systems and HHPD-VP method for the nonhomogeneous systems are given. This method not only takes the advantage of variational principle formula, which is much precise and is stiff A-stable, but also can avoid the truncation error of the computer. For the large systems, especially, the systems with different frequency or the stiff systems, our methods are stable, accurate and efficient. Numerical experiments show the convergence order of the scheme derived from the variational principle, and is much precise and is effective in engineering.

  1. Status and Outlook of CHIP-TRAP: the Central Michigan University High Precision Penning Trap

    CERN Document Server

    Redshaw, Matthew; Hawks, Paul; Gamage, Nadeesha D; Hunt, Curtis; Kandegedara, Rathnayake M E B; Ratnayake, Ishara S; Sharp, Lance

    2015-01-01

    At Central Michigan University we are developing a high-precision Penning trap mass spectrometer (CHIP-TRAP)that will focus on measurements with long-lived radioactive isotopes. CHIP-TRAP will consist of a pair of hyperbolic precision-measurement Penning traps, and a cylindrical capture/?filter trap in a 12 T magnetic field. Ions will be produced by external ion sources, including a laser ablation source, and transported to the capture trap at low energies enabling ions of a given m=q ratio to be selected via their time-of-flight. In the capture trap, contaminant ions will be removed with a mass-selective rf dipole excitation and the ion of interest will be transported to the measurement traps. A phase-sensitive image charge detection technique will be used for simultaneous cyclotron frequency measurements on single ions in the two precision traps, resulting in a reduction in statistical uncertainty due to magnetic field fluctuations.

  2. High precision measurements of the diamond Hugoniot in and above the melt region

    Energy Technology Data Exchange (ETDEWEB)

    Hicks, D; Boehly, T; Celliers, P; Bradley, D; Eggert, J; McWilliams, R S; Collins, G

    2008-08-05

    High precision laser-driven shock wave measurements of the diamond principal Hugoniot have been made at pressures between 6 and 19 Mbar. Shock velocities were determined with 0.3-1.1% precision using a velocity interferometer. Impedance matching analysis, incorporating systematic errors in the equation-of-state of the quartz standard, was used to determine the Hugoniot with 1.2-2.7% precision in density. The results are in good agreement with published ab initio calculations which predict a small negative melt slope along the Hugoniot, but disagree with previous laser-driven shock wave experiments which had observed a large density increase in the melt region. In the extensive solid-liquid coexistence regime between 6 and 10 Mbar these measurements indicate that the mixed phase may be slightly more dense than would be expected from a simple interpolation between liquid and solid Hugoniots.

  3. Development of high precision laser measurement to Space Debris and Applications in SHAO

    Science.gov (United States)

    Zhang, Zhongping; Chen, Juping; Xiong, Yaoheng; Han, Xingwei

    2016-07-01

    Artificial space debris has become the focus during the space exploration because of producing the damage for the future active spacecrafts and high precision measurement for space debris are required for debris surveillance and collision avoidance. Laser ranging technology is inherently high accurate and will play an important role in precise orbit determination, accurate catalog of space debris. Shanghai Astronomical Observatory (SHAO) of CAS, has been developing the technology of laser measurement to space debris for several years. According to characteristics of laser echoes from space debris and the experiences of relevant activities, high repetition rate, high power laser system and low dark noise APD detector with high quantum efficiency and high transmissivity of narrow bandwidth spectral filter are applied to laser measurement to space debris in SHAO. With these configurations, great achievements of laser measurement to space debris are made with hundreds of passes of laser data from space debris in the distance between 500km and 2500km with Radar Cross Section (RCS) of more than 10 m^{2} to less than 0.5m^{2} at the measuring precision of less than 1m (RMS). For better application of laser ranging technology, Chinese Space Debris Observation network, consisting of Shanghai, Changchun and Kunming station, has been preliminary developed and the coordinated observation has been performed to increase the measuring efficiency for space debris. It is referred from data that laser ranging technology can be as the essential high accuracy measurement technology in the study of space debris.

  4. SyPRID sampler: A large-volume, high-resolution, autonomous, deep-ocean precision plankton sampling system

    Science.gov (United States)

    Billings, Andrew; Kaiser, Carl; Young, Craig M.; Hiebert, Laurel S.; Cole, Eli; Wagner, Jamie K. S.; Van Dover, Cindy Lee

    2017-03-01

    The current standard for large-volume (thousands of cubic meters) zooplankton sampling in the deep sea is the MOCNESS, a system of multiple opening-closing nets, typically lowered to within 50 m of the seabed and towed obliquely to the surface to obtain low-spatial-resolution samples that integrate across 10 s of meters of water depth. The SyPRID (Sentry Precision Robotic Impeller Driven) sampler is an innovative, deep-rated (6000 m) plankton sampler that partners with the Sentry Autonomous Underwater Vehicle (AUV) to obtain paired, large-volume plankton samples at specified depths and survey lines to within 1.5 m of the seabed and with simultaneous collection of sensor data. SyPRID uses a perforated Ultra-High-Molecular-Weight (UHMW) plastic tube to support a fine mesh net within an outer carbon composite tube (tube-within-a-tube design), with an axial flow pump located aft of the capture filter. The pump facilitates flow through the system and reduces or possibly eliminates the bow wave at the mouth opening. The cod end, a hollow truncated cone, is also made of UHMW plastic and includes a collection volume designed to provide an area where zooplankton can collect, out of the high flow region. SyPRID attaches as a saddle-pack to the Sentry vehicle. Sentry itself is configured with a flight control system that enables autonomous survey paths to low altitudes. In its verification deployment at the Blake Ridge Seep (2160 m) on the US Atlantic Margin, SyPRID was operated for 6 h at an altitude of 5 m. It recovered plankton samples, including delicate living larvae, from the near-bottom stratum that is seldom sampled by a typical MOCNESS tow. The prototype SyPRID and its next generations will enable studies of plankton or other particulate distributions associated with localized physico-chemical strata in the water column or above patchy habitats on the seafloor.

  5. High-Precision U-Pb Zircon Dates as Benchmarks in Absolute Time

    Science.gov (United States)

    Schmitz, M. D.; Bowring, S. A.; Schoene, B.

    2003-12-01

    High-precision IDTIMS U-Pb zircon dates provide the most precise and accurate isotopic benchmarks in absolute time, due to the concordancy check of the paired U-Pb decay schemes, the precisely measured 235U and 238U decay constants, very high initial parent/daughter ratios, and the robust nature of zircon to loss or gain of U and Pb over geologic time. However, caveats to the use of such zircon dates include the accurate assessment and minimization of random and systematic errors in the analytical methods, and decay constant uncertainties. Unfortunately, there exists little consensus within the U-Pb geochronological community regarding an international zircon standard for the external assessment of interlaboratory reproducibility, while residual questions remain regarding the potential for systematic error in the single available high-precision counting experiment of the U decay constants1. Stringent criteria are imposed on candidates for zircon geochronology standards including the absence of inheritance and Pb-loss at both the single grain scale and the resolution of microbeam techniques. We present an example of the potential and limitations of a possible zircon standard, AS3, from the Duluth Complex, North American Midcontinent Rift2. New data for 27 single zircons are indistinguishable from prior results, with 207Pb/206Pb and upper intercept dates identical within error to a U-Pb concordia date of 1099.1+/-0.2 Ma (+/-1.2 Ma with systematic errors) based on 12 concordant and equivalent analyses. However, we must reiterate that a zircon population exhibiting consistent concordancy remains elusive, as AS3 and all Paleozoic and older standard candidates so far examined contain grains exhibiting Pb-loss, although rigorous selection and preparation of zircons through diamagnetic separation and aggressive abrasion can mitigate this phenomenon. The continued screening of candidate standards by both IDTIMS and SHRIMP techniques should be an organized, international

  6. High precision mobile location framework and its service based on virtual reference station of GPS

    Science.gov (United States)

    Liu, Chun; Sun, Liangyu; Yao, Lianbi

    2008-10-01

    The wireless communication technology and space technology are synchronously developed in recent years, which bring up the development of location based service (LBS). At present, many location technology methods were developed. However, all these methods can only provide a relative poor location precision and depend on high cost. The technology of Virtual Reference Station (VRS) of GPS is then involved in this paper. One of the objective in this paper is aim to give the LBS position structure to improve the mobile location position when a mobile position instrument is connected with VRS network. The cheaper GPS built-in Personal Designer Aid (PDA) is then used to achieve a higher precision by using RTCM data from existing VRS network. In order to obtain a high precision position when using the low-cost GPS receiver as a rover, the infrusture of the mobile differential correction system is then put forward. According to network transportation of RTCM via internet protocol (NTRIP), the message is communicated through wireless network, such as GPRS, CDMA and so on. The rough coordinate information is sent to VRS control center continuously, and then the VRS correction information is replied to rover in the data format of RTCM3.1. So the position will be updated based on mathematic solution after the decoding of RTCM3.1 data. The thought of LBS position can improve the precision, and can speed the LBS.

  7. A study on using image serving technology for high precision mechanical positioning

    Science.gov (United States)

    Lin, Chuen-Horng; Hsiao, Muh-Don; Lai, Kuo-Jung

    2016-12-01

    This paper focused on using image server technology for high precision mechanical positioning. Rapid and precise positioning systems depend on the correct positions of CCD (Charge Coupled Device) video cameras, as well as on pattern matching modes. This study deals with four different positions captured by an automatic detection system employing a CCD video camera. According to a variety of hybrid image registration systems, this study proposes an entire set of methods for achieving optimal hybrid pattern matching. First, the four different position detections captured by the CCD video camera in low-resolution were examined. Next, the original position detection was carried out in high-resolution, in order to derive a precise set of CCD video camera positions. The fiducial mark (FM) was then divided into two types in the optimal option for pattern matching: the "fiducial mark" and "non-fiducial mark", which were then used for sampling. The automatic detection method is able to achieve the first pattern matching detection for recognized images. Unrecognized images or images that cannot have an FM were subjected to fine pattern matching detection. When it is not possible to find more than one FM after the proposed detection method, this suggests that the position of the CCD video camera should be reset. In this paper, the results of the experiment regarding the CCD camera precision location and the segmentation of fiducial patterns or insignificant fiducial patterns can detect and segment more unique areas and areas with unique features.

  8. Development and simulation of microfluidic Wheatstone bridge for high-precision sensor

    Science.gov (United States)

    Shipulya, N. D.; Konakov, S. A.; Krzhizhanovskaya, V. V.

    2016-08-01

    In this work we present the results of analytical modeling and 3D computer simulation of microfluidic Wheatstone bridge, which is used for high-accuracy measurements and precision instruments. We propose and simulate a new method of a bridge balancing process by changing the microchannel geometry. This process is based on the “etching in microchannel” technology we developed earlier (doi:10.1088/1742-6596/681/1/012035). Our method ensures a precise control of the flow rate and flow direction in the bridge microchannel. The advantage of our approach is the ability to work without any control valves and other active electronic systems, which are usually used for bridge balancing. The geometrical configuration of microchannels was selected based on the analytical estimations. A detailed 3D numerical model was based on Navier-Stokes equations for a laminar fluid flow at low Reynolds numbers. We investigated the behavior of the Wheatstone bridge under different process conditions; found a relation between the channel resistance and flow rate through the bridge; and calculated the pressure drop across the system under different total flow rates and viscosities. Finally, we describe a high-precision microfluidic pressure sensor that employs the Wheatstone bridge and discuss other applications in complex precision microfluidic systems.

  9. SMILETRAP - A Penning trap facility for precision mass measurements using highly charged ions

    CERN Document Server

    Bergström, I; Fritioff, T; Douysset, G; Schoenfelder, J; Schuch, R

    2002-01-01

    The precision of mass measurements in a Penning trap increases linearly with the charge of the ion. Therefore we have attached a Penning trap, named SMILETRAP, to the electron beam ion source CRYSIS at MSL. CRYSIS is via an isotope separator connected to an ion source that can deliver singly charged ions of practically any element. In CRYSIS charge state breeding occurs by intense electron bombardment. We have shown that it is possible to produce, catch and measure the cyclotron frequencies of ions in the charge region 1+ to 52+. The relevant observable in mass measurements using a Penning trap is the ratio of the cyclotron frequencies of the ion of interest and ion used as a mass reference. High precision requires that the two frequencies are measured after one another in the shortest possible time. For reasons of convenience the precision trap operates at room temperature. So far it has been believed that warm traps working at 4 K are required for high mass precision with exactly one ion in the trap at a ti...

  10. High Precision Measurement of the differential vector boson cross-sections with the ATLAS detector

    CERN Document Server

    Armbruster, Aaron James; The ATLAS collaboration

    2017-01-01

    Measurements of the Drell-Yan production of W and Z/gamma bosons at the LHC provide a benchmark of our understanding of perturbative QCD and probe the proton structure in a unique way. The ATLAS collaboration has performed new high precision measurements at center-of-mass energies of 7. The measurements are performed for W+, W- and Z/gamma bosons integrated and as a function of the boson or lepton rapidity and the Z/gamma* mass. Unprecedented precision is reached and strong constraints on Parton Distribution functions, in particular the strange density are found. Z cross sections are also measured at center-of-mass energies of 8 eV and 13TeV, and cross-section ratios to the top-quark pair production have been derived. This ratio measurement leads to a cancellation of systematic effects and allows for a high precision comparison to the theory predictions. The cross section of single W events has also been measured precisely at center-of-mass energies of 8TeV and 13TeV and the W charge asymmetry has been determ...

  11. High-precision optical systems with inexpensive hardware: a unified alignment and structural design approach

    Science.gov (United States)

    Winrow, Edward G.; Chavez, Victor H.

    2011-09-01

    High-precision opto-mechanical structures have historically been plagued by high costs for both hardware and the associated alignment and assembly process. This problem is especially true for space applications where only a few production units are produced. A methodology for optical alignment and optical structure design is presented which shifts the mechanism of maintaining precision from tightly toleranced, machined flight hardware to reusable, modular tooling. Using the proposed methodology, optical alignment error sources are reduced by the direct alignment of optics through their surface retroreflections (pips) as seen through a theodolite. Optical alignment adjustments are actualized through motorized, sub-micron precision actuators in 5 degrees of freedom. Optical structure hardware costs are reduced through the use of simple shapes (tubes, plates) and repeated components. This approach produces significantly cheaper hardware and more efficient assembly without sacrificing alignment precision or optical structure stability. The design, alignment plan and assembly of a 4" aperture, carbon fiber composite, Schmidt-Cassegrain concept telescope is presented.

  12. A near infrared laser frequency comb for high precision Doppler planet surveys

    Directory of Open Access Journals (Sweden)

    Bally J.

    2011-07-01

    Full Text Available Perhaps the most exciting area of astronomical research today is the study of exoplanets and exoplanetary systems, engaging the imagination not just of the astronomical community, but of the general population. Astronomical instrumentation has matured to the level where it is possible to detect terrestrial planets orbiting distant stars via radial velocity (RV measurements, with the most stable visible light spectrographs reporting RV results the order of 1 m/s. This, however, is an order of magnitude away from the precision needed to detect an Earth analog orbiting a star such as our sun, the Holy Grail of these efforts. By performing these observations in near infrared (NIR there is the potential to simplify the search for distant terrestrial planets by studying cooler, less massive, much more numerous class M stars, with a tighter habitable zone and correspondingly larger RV signal. This NIR advantage is undone by the lack of a suitable high precision, high stability wavelength standard, limiting NIR RV measurements to tens or hundreds of m/s [1, 2]. With the improved spectroscopic precision provided by a laser frequency comb based wavelength reference producing a set of bright, densely and uniformly spaced lines, it will be possible to achieve up to two orders of magnitude improvement in RV precision, limited only by the precision and sensitivity of existing spectrographs, enabling the observation of Earth analogs through RV measurements. We discuss the laser frequency comb as an astronomical wavelength reference, and describe progress towards a near infrared laser frequency comb at the National Institute of Standards and Technology and at the University of Colorado where we are operating a laser frequency comb suitable for use with a high resolution H band astronomical spectrograph.

  13. Interaction of fatigue and creep of GH33 under multi-axial stress at high temperature

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Low-cycle fatigue experiments of tension-compression, torsion and tension-torsion with holding time were performed.The interaction law of creep and fatigue under multiaxial stress at high temperature was investigated, and the micro-mechanism ofequilibrium diagrams was analyzed. A united equation of fatigue life under multiaxial stress was proposed.

  14. High-Precision Half-Wave Rectifier Circuit In Dual Phase Output Mode

    Directory of Open Access Journals (Sweden)

    Theerayut Jamjaem

    2009-12-01

    Full Text Available This paper present high-precision half-wave rectifier circuit in dual phase output mode by 0.5 μm CMOS technology, +/- 1.5 V low voltage, it has received input signal and sent output current signal, respond in high frequency. The main structure compound with CMOS inverter circuit, common source circuit, and current mirror circuit. Simulation and confirmation quality of working by PSpice program, then it able to operating at maximum frequency about 100 MHz, maximum input current range about 400 μAp-p, high precision output signal, low power dissipation, and uses a little transistor.Keywords-component; half-wave; rectifier circuit; highprecession; dual phase;

  15. Process influences and correction possibilities for high precision injection molded freeform optics

    Science.gov (United States)

    Dick, Lars; Risse, Stefan; Tünnermann, Andreas

    2016-08-01

    Modern injection molding processes offer a cost-efficient method for manufacturing high precision plastic optics for high volume applications. Besides form deviation of molded freeform optics, internal material stress is a relevant influencing factor for the functionality of a freeform optics in an optical system. This paper illustrates dominant influence parameters of an injection molding process relating to form deviation and internal material stress based on a freeform demonstrator geometry. Furthermore, a deterministic and efficient way for 3D mold correcting of systematic, asymmetrical shrinkage errors is shown to reach micrometer range shape accuracy at diameters up to 40 mm. In a second case, a stress-optimized parameter combination using unusual molding conditions was 3D corrected to reach high precision and low stress freeform polymer optics.

  16. An Approach to Predicting Hydrocarbon with High Precision Gravity and Seismic Data

    Institute of Scientific and Technical Information of China (English)

    Wang Xiwen

    1996-01-01

    @@ There are two ways for predicting hydrocarbon reservoirs with gravity data. One is related to the indirect prediction techniques used to delineate hydrocarbon-bearing structures with dense grids of survey and high-precision gravity data. The other is direct prediction technique based on high precision gravity data, which is used to measure negative anomalies resulted from significant density changes of porous formations when saturated with different kinds of liquid. The density change of porous formations may be as high as -0.3 × 103 to -0.1 × 103kg/m3 when saturated with oil instead of water and -0.6× 103 to -0.2 × 103 kg/m3 when saturated with gas instead of water.

  17. High-speed, high-precision thermal printing heads for bar code printers; Kosoku koseisai bar cord printer yo TPH

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    Thermal printing heads (TPHs), having the world's first resolution of 24 dots/mm and printing speed of 254 mm/s, have been developed. The high-precision, high-durability TPH is realized, based on the high-precision techniques as one of the company's strong areas, combined with the techniques for high power-resistant film structure and high wear-resistant protective film. At the same time, the structure of high thermal conductivity and thermal efficiency is adopted, to control heat accumulation and realize high-quality images. It is expected to find wide use in various areas, centered by distribution industry, e.g., for bar code label printers, and name plate, postal card and name card printing, with the standardized recording width of A6 size and resolution of 8 to 24 dots/mm. (translated by NEDO)

  18. The Conceptual Design of High Pressure Reversible Axial Tunnel Ventilation Fans

    Directory of Open Access Journals (Sweden)

    A. G. Sheard

    2012-01-01

    Full Text Available Tunnel ventilation fans, classically, must have the ability to both supply and extract air from a tunnel system, with the operator's choice dependent on the tunnel ventilation system's operating mode most appropriate at any given point in time. Consequently, tunnel ventilation fans must incorporate a reversible aerodynamic design which limits the maximum fan pressure rise. This paper presents three high pressure reversible fan concepts. These comprise a two-stage counter rotating fan, a single-stage high speed fan, and a two-stage fan with a single motor and impeller on each end of the motor shaft. The authors consider the relative merits of each concept. The third concept offers the most compact fan, transform, silencer, and damper package size. The authors discuss the mechanical design challenges that occur with a two-stage fan with a single motor and impeller on each end of the motor shaft. They present and consider a selected motor bearing arrangement and casing design for maintainability. Finally, the authors present both prototype fan and full-scale package aerodynamic and acoustic performance, before discussing the challenges presented by high temperature certification in accordance with the requirements of EN 12101-3: 2012.

  19. High-throughput dual-color precision imaging for brain-wide mapping of the connectome with cytoarchitectonic landmarks at the cellular level (Conference Presentation)

    Science.gov (United States)

    Luo, Qingming; Gong, Hui; Yuan, Jing; Li, Xiangning; Li, Anan; Xu, Tonghui

    2017-02-01

    Deciphering the fine morphology and precise location of neurons and neural circuits are crucial to enhance our understanding of brain function and diseases. Traditionally, we have to map brain images to coarse axial-sampling planar reference atlases to orient neural structures. However, this means might fail to orient neural projections at single-cell resolution due to position errors resulting from individual differences at the cellular level. Here, we present a high-throughput imaging method that can automatically obtain the fine morphologies and precise locations of both neurons and circuits, employing wide-field large-volume tomography to acquire three-dimensional images of thick tissue and implementing real-time soma counterstaining to obtain cytoarchitectonic landmarks during the imaging process. The reconstruction and orientation of brain-wide neural circuits at single-neuron resolution can be accomplished for the same mouse brain without additional counterstains or image registration. Using our method, mouse brain imaging datasets of multiple type-specific neurons and circuits were successfully acquired, demonstrating the versatility. The results show that the simultaneous acquisition of labeled neural structures and cytoarchitecture reference at single-neuron resolution in the same brain greatly facilitates precise tracing of long-range projections and accurate locating of nuclei. Our method provides a novel and effective tool for application in studies on genetic dissection, brain function and the pathology of the nervous system.

  20. Overview spectra and axial distribution of spectral line intensities in a high-current vacuum arc with CuCr electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Lisnyak, M.; Pipa, A. V.; Gorchakov, S., E-mail: gorchakov@inp-greifswald.de, E-mail: weltmann@inp-greifswald.de; Iseni, S.; Franke, St.; Khapour, A.; Methling, R.; Weltmann, K.-D., E-mail: gorchakov@inp-greifswald.de, E-mail: weltmann@inp-greifswald.de [Leibniz-Institut für Plasmaforschung und Technologie e.V., Felix-Hausdorff-Straße 2, 17489 Greifswald (Germany)

    2015-09-28

    Spectroscopic investigations of free-burning vacuum arcs in diffuse mode with CuCr electrodes are presented. The experimental conditions of the investigated arc correspond to the typical system for vacuum circuit breakers. Spectra of six species Cu I, Cu II, Cu III, Cr I, Cr II, and Cr III have been analyzed in the wavelength range 350–810 nm. The axial intensity distributions were found to be strongly dependent on the ionization stage of radiating species. Emission distributions of Cr II and Cu II can be distinguished as well as the distributions of Cr III and Cu III. Information on the axial distribution was used to identify the spectra and for identification of overlapping spectral lines. The overview spectra and some spectral windows recorded with high resolution are presented. Analysis of axial distributions of emitted light, which originates from different ionization states, is presented and discussed.

  1. Research on Axial Trail of High-Speed Gas Painting Automizor

    Institute of Scientific and Technical Information of China (English)

    杨志永; 张大卫; 黄田

    2003-01-01

    The non-linear dynamic model is set up of one type of high-speed painting automizor with gas supporting system. The stability of motion and dynamic response of the gas painting automizor system are studied over a relatively wide range of rotating speed by numerical analytic method, the critical velocity under working condition is found, and rotate stability and critical condition are discussed in theory. Furthermore, the range of the critical parameter of the system when Hopf bifurcation occurs and the law between axis trace and bearing clearance are acquired, too.

  2. The high Reynolds number flow through an axial-flow pump

    Science.gov (United States)

    Zierke, W. C.; Straka, W. A.; Taylor, P. D.

    1993-11-01

    The high Reynolds number pump (HIREP) facility at ARL Penn State has been used to perform a low-speed, large-scale experiment of the incompressible flow of water through a two-blade-row turbomachine. HIREP can involve blade chord Reynolds numbers as high as 6,000,000 and can accommodate a variety of instrumentation in both a stationary and a rotating frame of reference. The objectives of this experiment were as follows: to provide a database for comparison with three-dimensional, viscous (turbulent) flow computations; to evaluate the engineering models; and to improve our physical understanding of many of the phenomena involved in this complex flow field. The experimental results include a large quantity of data acquired throughout HIREP. A five-hole probe survey of the inlet flow 37.0 percent chord upstream of the inlet guide vane (IGV) leading edge is sufficient to give information for the inflow boundary conditions, while some static-pressure information is available to help establish an outflow boundary condition.

  3. Structural integrity assessments of high pressure pipelines with axial flaws using a micromechanics model

    Energy Technology Data Exchange (ETDEWEB)

    Dotta, Fernando; Ruggieri, Claudio

    2004-09-01

    This study extends a micromechanics approach based upon the computational cell methodology to model ductile crack extension of longitudinal crack-like defects in a high strength pipeline steel. Laboratory testing of an API 5L X60 steel at room temperature using standard, deep crack C(T) specimens provides the data needed to measure the crack growth resistance curve for the material. A simple scheme to calibrate material-specific parameters for the cells employs this measured R-curve. A central focus of the paper is the application of the cell methodology to predict experimentally measured burst pressures for longitudinally pre-cracked pipe specimens. The experimental program includes large-diameter pipe specimens with different crack depth (a) and crack size (2c). Plane-strain computations are conducted on detailed finite element models for the pipe specimens to describe crack extension with increased pressure. The cell model predictions of crack growth response and burst pressure predictions are in good agreement with experimental measurements for the tested pipes. The present methodology holds significant promise as an engineering tool to simulate ductile crack growth and to predict the burst pressure of high pressure pipelines containing crack-like defects.

  4. Experimental Investigation of the Hysteretic Behavior of Wide-Flange Steel Columns under High Axial Load and Lateral Drift Demands

    OpenAIRE

    Lignos, Dimitrios; Cravero, Julien; Elkady, Ahmed Mohamed Ahmed

    2016-01-01

    This paper discusses the findings from a large-scale experimental program that characterized the hysteretic behavior of typical steel wide-flange columns in steel moment-resisting frames (MRFs). The test specimens were tested in a cantilever configuration with a fixed point of inflection. The main testing parameters included various lateral and axial loading histories, the applied axial compressive load and the local slenderness of the cross-section. It is shown that (a) steel columns subject...

  5. A high-precision instrument for analyzing nonlinear dynamic behavior of bearing cage

    Science.gov (United States)

    Yang, Z.; Chen, H.; Yu, T.; Li, B.

    2016-08-01

    The high-precision ball bearing is fundamental to the performance of complex mechanical systems. As the speed increases, the cage behavior becomes a key factor in influencing the bearing performance, especially life and reliability. This paper develops a high-precision instrument for analyzing nonlinear dynamic behavior of the bearing cage. The trajectory of the rotational center and non-repetitive run-out (NRRO) of the cage are used to evaluate the instability of cage motion. This instrument applied an aerostatic spindle to support and spin test the bearing to decrease the influence of system error. Then, a high-speed camera is used to capture images when the bearing works at high speeds. A 3D trajectory tracking software tema Motion is used to track the spot which marked the cage surface. Finally, by developing the matlab program, a Lissajous' figure was used to evaluate the nonlinear dynamic behavior of the cage with different speeds. The trajectory of rotational center and NRRO of the cage with various speeds are analyzed. The results can be used to predict the initial failure and optimize cage structural parameters. In addition, the repeatability precision of instrument is also validated. In the future, the motorized spindle will be applied to increase testing speed and image processing algorithms will be developed to analyze the trajectory of the cage.

  6. A high-precision instrument for analyzing nonlinear dynamic behavior of bearing cage.

    Science.gov (United States)

    Yang, Z; Chen, H; Yu, T; Li, B

    2016-08-01

    The high-precision ball bearing is fundamental to the performance of complex mechanical systems. As the speed increases, the cage behavior becomes a key factor in influencing the bearing performance, especially life and reliability. This paper develops a high-precision instrument for analyzing nonlinear dynamic behavior of the bearing cage. The trajectory of the rotational center and non-repetitive run-out (NRRO) of the cage are used to evaluate the instability of cage motion. This instrument applied an aerostatic spindle to support and spin test the bearing to decrease the influence of system error. Then, a high-speed camera is used to capture images when the bearing works at high speeds. A 3D trajectory tracking software tema Motion is used to track the spot which marked the cage surface. Finally, by developing the matlab program, a Lissajous' figure was used to evaluate the nonlinear dynamic behavior of the cage with different speeds. The trajectory of rotational center and NRRO of the cage with various speeds are analyzed. The results can be used to predict the initial failure and optimize cage structural parameters. In addition, the repeatability precision of instrument is also validated. In the future, the motorized spindle will be applied to increase testing speed and image processing algorithms will be developed to analyze the trajectory of the cage.

  7. High-Precision Superallowed Fermi β Decay Measurements at TRIUMF-ISAC

    Science.gov (United States)

    Svensson, C. E.

    2016-09-01

    High-precision measurements of the ft -values for superallowed Fermi β decays between nuclear isobaric analogue states provide demanding tests of the electroweak Standard Model, including confirmation of the Conserved Vector Current hypothesis at the level of 1 . 2 ×10-4 , the most stringent limits on weak scalar currents, and the most precise determination of the Vud element of the CKM quark-mixing matrix. The Isotope Separator and Accelerator (ISAC) facility at TRIUMF produces high-quality beams of several of the superallowed emitters with world-record intensities and hosts a suite of state-of-the-art spectrometers for the measurement of superallowed half-lives, branching ratios, QEC values, and charge-radii. Recent highlights from the superallowed program at ISAC, including high-precision half-life measurements for the light superallowed emitters 10C, 14O, 18Ne, and 26mAl and branching-ratio measurements for the heavy superallowed emitters 62Ga and 74Rb will be presented. The impact of these measurements on tests of the Standard Model, and future developments in the superallowed program at ISAC with the new high-efficiency GRIFFIN γ - ray spectrometer, will be discussed. Research supported by the Natural Sciences and Engineering Research Council of Canada, the Canada Foundation for Innovation, and the Canada Research Chairs Program. TRIUMF receives federal funding via the National Research Council of Canada.

  8. Why precision?

    Energy Technology Data Exchange (ETDEWEB)

    Bluemlein, Johannes

    2012-05-15

    Precision measurements together with exact theoretical calculations have led to steady progress in fundamental physics. A brief survey is given on recent developments and current achievements in the field of perturbative precision calculations in the Standard Model of the Elementary Particles and their application in current high energy collider data analyses.

  9. High-Precision Image Aided Inertial Navigation with Known Features: Observability Analysis and Performance Evaluation

    Science.gov (United States)

    Jiang, Weiping; Wang, Li; Niu, Xiaoji; Zhang, Quan; Zhang, Hui; Tang, Min; Hu, Xiangyun

    2014-01-01

    A high-precision image-aided inertial navigation system (INS) is proposed as an alternative to the carrier-phase-based differential Global Navigation Satellite Systems (CDGNSSs) when satellite-based navigation systems are unavailable. In this paper, the image/INS integrated algorithm is modeled by a tightly-coupled iterative extended Kalman filter (IEKF). Tightly-coupled integration ensures that the integrated system is reliable, even if few known feature points (i.e., less than three) are observed in the images. A new global observability analysis of this tightly-coupled integration is presented to guarantee that the system is observable under the necessary conditions. The analysis conclusions were verified by simulations and field tests. The field tests also indicate that high-precision position (centimeter-level) and attitude (half-degree-level)-integrated solutions can be achieved in a global reference. PMID:25330046

  10. High-Precision Image Aided Inertial Navigation with Known Features: Observability Analysis and Performance Evaluation

    Directory of Open Access Journals (Sweden)

    Weiping Jiang

    2014-10-01

    Full Text Available A high-precision image-aided inertial navigation system (INS is proposed as an alternative to the carrier-phase-based differential Global Navigation Satellite Systems (CDGNSSs when satellite-based navigation systems are unavailable. In this paper, the image/INS integrated algorithm is modeled by a tightly-coupled iterative extended Kalman filter (IEKF. Tightly-coupled integration ensures that the integrated system is reliable, even if few known feature points (i.e., less than three are observed in the images. A new global observability analysis of this tightly-coupled integration is presented to guarantee that the system is observable under the necessary conditions. The analysis conclusions were verified by simulations and field tests. The field tests also indicate that high-precision position (centimeter-level and attitude (half-degree-level-integrated solutions can be achieved in a global reference.

  11. Determination of the half-life of 213Fr with high precision

    Science.gov (United States)

    Fisichella, M.; Musumarra, A.; Farinon, F.; Nociforo, C.; Del Zoppo, A.; Figuera, P.; La Cognata, M.; Pellegriti, M. G.; Scuderi, V.; Torresi, D.; Strano, E.

    2013-07-01

    High-precision measurement of half-life and Qα value of neutral and highly charged α emitters is a major subject of investigation currently. In this framework, we recently pushed half-life measurements of neutral emitters to a precision of a few per mil. This result was achieved by using different techniques and apparatuses at Istituto Nazionale di Fisica Nucleare Laboratori Nazionali del Sud (INFN-LNS) and GSI Darmstadt. Here we report on 213Fr half-life determination [T1/2(213Fr) = 34.14±0.06 s] at INFN-LNS, detailing the measurement protocol used. Direct comparison with the accepted value in the literature shows a discrepancy of more than three sigma. We propose this new value as a reference, discussing previous experiments.

  12. A Study of Particle Beam Spin Dynamics for High Precision Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Fiedler, Andrew J. [Northern Illinois Univ., DeKalb, IL (United States)

    2017-05-01

    In the search for physics beyond the Standard Model, high precision experiments to measure fundamental properties of particles are an important frontier. One group of such measurements involves magnetic dipole moment (MDM) values as well as searching for an electric dipole moment (EDM), both of which could provide insights about how particles interact with their environment at the quantum level and if there are undiscovered new particles. For these types of high precision experiments, minimizing statistical uncertainties in the measurements plays a critical role. \\\\ \\indent This work leverages computer simulations to quantify the effects of statistical uncertainty for experiments investigating spin dynamics. In it, analysis of beam properties and lattice design effects on the polarization of the beam is performed. As a case study, the beam lines that will provide polarized muon beams to the Fermilab Muon \\emph{g}-2 experiment are analyzed to determine the effects of correlations between the phase space variables and the overall polarization of the muon beam.

  13. Quality of silicon convex lenses fabricated by ultra-high precision diamond machining

    Directory of Open Access Journals (Sweden)

    Abou-El-Hossein, K.

    2013-05-01

    Full Text Available Infra-red optical components are made mainly from hard and brittle materials such as germanium and silicon. Silicon machining is characterised by some difficulties when ultra-high precision machined by mono-crystalline single-point diamond. Accelerated tool wear and machined-surface deterioration may take place if the machining parameters are not properly selected. In this study, we conducted a machining test on an ultra-high precision machine tool, using ductile regime cutting conditions when fabricating a convex surface on a silicon lens of aperture of 60 mm diameter, and using a mono-crystalline diamond. It was found that the cutting conditions for shaping a convex surface of 500 mm radius resulted in good form accuracy. However, more attention should be paid to optimising the holding force of the vacuum chuck employed.

  14. High Precision and High Yield Fabrication of Dense Nanoparticle Arrays onto DNA Origami at Statistically Independent Binding Sites †

    OpenAIRE

    Takabayashi, Sadao; Klein, William P.; Onodera, Craig; Rapp, Blake; Flores-Estrada, Juan; Lindau, Elias; Snowball, Lejmarc; Sam, Joseph Tyler; Padilla, Jennifer E.; Lee, Jeunghoon; Knowlton, William B.; Graugnard, Elton; Yurke, Bernard; Kuang, Wan; Hughes, William L.

    2014-01-01

    High precision, high yield, and high density self-assembly of nanoparticles into arrays is essential for nanophotonics. Spatial deviations as small as a few nanometers can alter the properties of near-field coupled optical nanostructures. Several studies have reported assemblies of few nanoparticle structures with controlled spacing using DNA nanostructures with variable yield. Here, we report multi-tether design strategies and attachment yields for homo- and hetero-nanoparticle arrays templa...

  15. Technological Considerations and Constraints in the Manufacture of High Precision Ball and Roller Bearings

    Directory of Open Access Journals (Sweden)

    Prof.S.Rajendiran,

    2015-12-01

    Full Text Available Rolling element bearings for application in Aircraft systems are to be manufactured to higher accuracy levels. Various technology details like raw material, processing stages and facilities such as machining, heat treatment, grinding, super finishing, assembly and inspection are to be considered for manufacture. However the facilities available presently in India are inadequate to produce high precision bearings. This paper deals with the prototype manufacture of bearings for some typical applications.

  16. Comment on "High-Precision Determination of the Electric and Magnetic Form Factors of the Proton"

    CERN Document Server

    Arrington, J

    2011-01-01

    In a recent Letter, Bernauer, et al. present fits to the proton electromagnetic form factors, GEp(Q^2) and GMp(Q^2), along with extracted proton charge and magnetization radii based on large set of new, high statistical precision (<0.2%) cross section measurements. The Coulomb corrections they apply differ dramatically from more modern and complete calculations, implying significant error in their final results.

  17. VizieR Online Data Catalog: High-precision abundances for stars with planets (Ramirez+, 2014)

    Science.gov (United States)

    Ramirez, I.; Melendez, J.; Asplund, M.

    2013-11-01

    High-precision stellar parameters and chemical abundances are presented for 111 stars; 52 of them are late-F type dwarfs and 59 are metal-rich solar analogs. The atomic linelist employed in the derivation of chemical abundances is also given. This linelist includes hyperfine structure parameters for some species. The stars' isochrone masses and ages are also reported, along with estimates of chromospheric activity. (5 data files).

  18. High-precision gravity network to monitor temporal variations in gravity across Yucca Mountain, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Harris, R.N.; Ponce, D.A.

    1988-12-31

    Repeatable high-precision gravity surveys provide a method of monitoring temporal variations in the gravity field. Fluctuations in the gravity field may indicate water table changes, crustal deformation, or precursors to volcanism and earthquakes. This report describes a high-precision gravity loop which has been established across Yucca Mountain, Nevada in support of the Nevada Nuclear Waste Storage Investigations (NNWSI) program. The purpose of this gravity loop is to monitor temporal variations in gravity across Yucca Mountain in an effort to interpret and predict the stability of the tectonic framework and changes in the subsurface density field. Studies of the tectonic framework which include volcanic hazard seismicity, and faulting studies are in progress. Repeat high-precision gravity surveys are less expensive and can be made more rapidly than a corresponding leveling survey. High-precision gravity surveys are capable of detecting elevation changes of 3 to 5 cm, and thus can be employed as an efficient tool for monitoring vertical crustal movements while supplementing or partially replacing leveling data. The Yucca Mountain gravity network has been tied to absolute gravity measurements established in southern Nevada. These ties provide an absolute datum for comparing repeat occupations of the gravity network, and provide a method of monitoring broad-scale changes in gravity. Absolute gravity measurements were also made at the bottom and top of the Charleston Peak calibration loop in southern Nevada. These absolute gravity measurements provide local control of calibrating gravity meters over the gravity ranges observed at Yucca Mountain. 13 refs., 7 figs., 3 tabs.

  19. High Precision Measurements of $\\theta_{\\odot}$ in Solar and Reactor Neutrino Experiments

    CERN Document Server

    Bandyopadhyay, A; Goswami, S; Petcov, S T; Bandyopadhyay, Abhijit; Choubey, Sandhya; Goswami, Srubabati

    2004-01-01

    We discuss the possibilities of high precision measurement of the solar neutrino mixing angle $\\theta_\\odot \\equiv \\theta_{12}$ in solar and reactor neutrino experiments. The improvements in the determination of $\\sin^2\\theta_{12}$, which can be achieved with the expected increase of statistics and reduction of systematic errors in the currently operating solar and KamLAND experiments, are summarised. The potential of LowNu $\

  20. Development of a monoenergetic ultraslow antiproton beam source for high-precision investigation

    Directory of Open Access Journals (Sweden)

    N. Kuroda

    2012-02-01

    Full Text Available The ASACUSA collaboration developed an ultraslow antiproton beam source, monoenergetic ultraslow antiproton source for high-precision investigation (MUSASHI, consisting of an electromagnetic trap with a liquid He free superconducting solenoid and a low energy antiproton beam transport line. The MUSASHI was capable of trapping and cooling more than 1×10^{7} antiprotons and extracting them as an ultraslow antiproton beam with energy of 150–250 eV.

  1. Computer Vision Approach for Low Cost, High Precision Measurement of Grapevine Trunk Diameter in Outdoor Conditions

    OpenAIRE

    Pérez, Diego Sebastián; Bromberg, Facundo; Antivilo, Francisco Gonzalez

    2014-01-01

    Trunk diameter is a variable of agricultural interest, used mainly in the prediction of fruit trees production. It is correlated with leaf area and biomass of trees, and consequently gives a good estimate of the potential production of the plants. This work presents a low cost, high precision method for the measurement of trunk diameter of grapevines based on Computer Vision techniques. Several methods based on Computer Vision and other techniques are introduced in the literature. These metho...

  2. A CFD analysis of blade row interactions within a high-speed axial compressor

    Science.gov (United States)

    Richman, Michael Scott

    Aircraft engine design provides many technical and financial hurdles. In an effort to streamline the design process, save money, and improve reliability and performance, many manufacturers are relying on computational fluid dynamic simulations. An overarching goal of the design process for military aircraft engines is to reduce size and weight while maintaining (or improving) reliability. Designers often turn to the compression system to accomplish this goal. As pressure ratios increase and the number of compression stages decrease, many problems arise, for example stability and high cycle fatigue (HCF) become significant as individual stage loading is increased. CFD simulations have recently been employed to assist in the understanding of the aeroelastic problems. For accurate multistage blade row HCF prediction, it is imperative that advanced three-dimensional blade row unsteady aerodynamic interaction codes be validated with appropriate benchmark data. This research addresses this required validation process for TURBO, an advanced three-dimensional multi-blade row turbomachinery CFD code. The solution/prediction accuracy is characterized, identifying key flow field parameters driving the inlet guide vane (IGV) and stator response to the rotor generated forcing functions. The result is a quantified evaluation of the ability of TURBO to predict not only the fundamental flow field characteristics but the three dimensional blade loading.

  3. Corner Separation Control by Boundary Layer Suction Applied to a Highly Loaded Axial Compressor Cascade

    Directory of Open Access Journals (Sweden)

    Yangwei Liu

    2014-11-01

    Full Text Available Control of corner separation has attracted much interest due to its improvement of performance and energy utilization in turbomachinery. Numerical studies have been performed under both design and off-design flow conditions to investigate the effects of boundary layer suction (BLS on corner separation in a highly loaded compressor cascade. Two new BLS slot configurations are proposed and a total of five suction slot configurations were studied and compared. Averaged static pressure rise, exit loss coefficient, passage blockage and flow turning angle have been given and compared systematically over a range of operation incidence angles. Distributions of significant loss removal, blade loading, exit deviation and total pressure loss at 3 degree and 7 degree incidence have also been studied. Under the same suction mass flows of 0.7% of the inlet mass flows, the pitchwise suction slot on the endwall shows a better optimal performance over the whole operation incidence among single suction slots. By using of the new proposed compound slot configuration with one spanwise slot on the blade suction side and one pitchwise slot on the endwall, the maximum reduction of total pressure loss at 7 degree incidence can be 39.4%.

  4. High stability integrated Tri-axial fluxgate sensor with suspended technology

    Science.gov (United States)

    Wang, Chen; Teng, Yuntian; Wang, Xiaomei; Fan, Xiaoyong; Wu, Qiong

    2017-04-01

    The relative geomagnetic record of China Geomagnetic Network of China(GNC) has been digitized, network, meanwhile achieving second data acquisition and storage during after 9th five-year and 10th five-year plan upgraded. Currently the relative record in geomagnetic observatories are generally two sets of the same type instrument with parallel observation, which could distinguish the differential between observation instrument failures and environmental interference, and ensure the continuity and integrity of the observation data. Fluxgate magnetometer has become mainstream equipment for relative geomagnetic record because of its low noise, high sensitivity, and fast response. There is a problem about data inconsistency by the same type of instrument in the same station though few years observation data analysis. The researchers have done a lot of experiments and found three main error sources:1. The instrument performances, due to the limitation of manufacturing and assembly process level it is difficult to ensure the orthogonality of the instrument; other performances of scale, zero offset and temperature coefficient; 2. horizontal error, which introduced by the initial installation process due to horizontal adjustment and pillar tilling due to long-term observations; 3.The observation environment, the temperature and humidity, power supply system. The new fluxgate magnetometer uses special nonmagnetic gimbaled (made by beryllium / bronze material) construction for suspension, so the fluxgate sensor is fixed at the suspended platform in order to automatically keep the horizontal level. The advantage of this design is to eliminate horizontal error introduced by the initial installation process due to horizontal adjustment and pillar tilling due to long-term observations. The signal processing circuit board is fixed on the top of the suspended platform with certain distance to ensure the static and dynamic magnetic field produced by circuit board no effect to the

  5. High Precision Topographic Mapping at Chang'E-3 Landing Site with Multi-Source Data

    Science.gov (United States)

    Liu, Y.; Liu, B.; Xu, B.; Liu, Z.; Di, K.; Zhou, J.

    2014-04-01

    Chang'e-3 (CE-3) is the first lander and rover of China following the success of Chang'e-1 and Chang'e-2 (CE-2) orbiters. High precision topographic mapping can provide detailed terrain information to ensure the safety of the rover as well as to support scientific investigations. In this research, multi-source data are co-registered into a uniform geographic framework for high precision topographic mapping at the CE-3 landing site. CE-2 CCD images with 7 m- and 1.5 m- resolutions are registered using selfcalibration bundle adjustment method with ground control points (GCPs) selected from LRO WAC mosaic map and LOLA DTM. The trajectory of CE-3 descent images are recovered using self-calibration free net bundle adjustment, and then the topographic data is rectified by absolute orientation with GCPs selected from the adjusted CE-2 DEM and DOM. Finally, these topographic data are integrated into the same geographic framework for unified, multi-scale, high precision mapping of the CE-3 landing site. Key technologies and the mapping products of this research have been used to support the surface operations of CE-3 mission.

  6. Design and Characterization of a High-Precision Digital Electromagnetic Actuator with Four Discrete Positions

    Directory of Open Access Journals (Sweden)

    Laurent Petit

    2015-10-01

    Full Text Available A high-precision planar digital electromagnetic actuator with two displacement directions and four discrete positions is presented in this paper. The four discrete positions are located at each corner of a square cavity where a mobile permanent magnet moves thanks to Lorentz forces generated when a driving current passes through two orthogonal wires placed below the cavity. Four fixed permanent magnets are placed around the cavity in order to ensure high-precision magnetic holding of the mobile magnet at each discrete position. An analytical model of the actuator is presented and used to characterize its properties (switching time, energy consumption, and displaceable mass. Based on this model, an experimental prototype has been developed and then characterized. Comparisons between experimental and simulated results are carried out and show good agreement. The positioning repeatability errors have also been characterized according to the input signal in order to qualify the digital behavior of this high-precision actuator. Finally, an application of this digital actuator as a linear conveyor is presented and experimentally tested.

  7. High-precision comparison of the antiproton-to-proton charge-to-mass ratio

    CERN Document Server

    Ulmer, S; Mooser, A; Franke, K; Nagahama, H; Schneider, G; Higuchi, T; Van Gorp, S; Blaum, K; Matsuda, Y; Quint, W; Walz, J; Yamazaki, Y

    2015-01-01

    Invariance under the charge, parity, time-reversal (CPT) transformation$^{1}$ is one of the fundamental symmetries of the standard model of particle physics. This CPT invariance implies that the fundamental properties of antiparticles and their matter-conjugates are identical, apart from signs. There is a deep link between CPT invariance and Lorentz symmetry—that is, the laws of nature seem to be invariant under the symmetry transformation of spacetime—although it is model dependent$^{2}$. A number of high-precision CPT and Lorentz invariance tests—using a co-magnetometer, a torsion pendulum and a maser, among others—have been performed$^{3}$, but only a few direct high-precision CPT tests that compare the fundamental properties of matter and antimatter are available$^{4, 5, 6, 7, 8}$. Here we report high-precision cyclotron frequency comparisons of a single antiproton and a negatively charged hydrogen ion (H$^−$) carried out in a Penning trap system. From 13,000 frequency measurements we compare th...

  8. The honeycomb strip chamber: A two coordinate and high precision muon detector

    Energy Technology Data Exchange (ETDEWEB)

    Tolsma, H.P.T.

    1996-04-19

    This thesis describes the construction and performance of the Honeycomb Strip Chamber (HSC). The HSC offers several advantages with respect to classical drift chambers and drift tubes. The main features of the HSC are: -The detector offers the possibility of simultaneous readout of two orthogonal coordinates with approximately the same precision. - The HSC technology is optimised for mass production. This means that the design is modular (monolayers) and automisation of most of the production steps is possible (folding and welding machines). - The technology is flexible. The cell diameter can easily be changed from a few millimetres to at least 20 mm by changing the parameters in the computer programme of the folding machine. The number of monolayers per station can be chosen freely to the demands of the experiment. -The honeycomb structure gives the detector stiffness and makes it self supporting. This makes the technology a very transparent one in terms of radiation length which is important to prevent multiple scattering of high energetic muons. - The dimensions of the detector are defined by high precision templates. Those templates constrain for example the overall tolerance on the wire positions to 20 {mu}m rms. Reproduction of the high precision assembly of the detector is thus guaranteed. (orig.).

  9. Next generation KATRIN high precision voltage divider for voltages up to 65kV

    CERN Document Server

    Bauer, S; Hochschulz, F; Ortjohann, H -W; Rosendahl, S; Thümmler, T; Schmidt, M; Weinheimer, C

    2013-01-01

    The KATRIN (KArlsruhe TRItium Neutrino) experiment aims to determine the mass of the electron antineutrino with a sensitivity of 200meV by precisely measuring the electron spectrum of the tritium beta decay. This will be done by the use of a retarding spectrometer of the MAC-E-Filter type. To achieve the desired sensitivity the stability of the retarding potential of -18.6kV has to be monitored with a precision of 3ppm over at least two months. Since this is not feasible with commercial devices, two ppm-class high voltage dividers were developed, following the concept of the standard divider for DC voltages of up to 100kV of the Physikalisch-Technische Bundesanstalt (PTB). In order to reach such high accuracies different effects have to be considered. The two most important ones are the temperature dependence of resistance and leakage currents, caused by insulators or corona discharges. For the second divider improvements were made concerning the high-precision resistors and the thermal design of the divider....

  10. Concept of modular flexure-based mechanisms for ultra-high precision robot design

    Directory of Open Access Journals (Sweden)

    M. Richard

    2011-05-01

    Full Text Available This paper introduces a new concept of modular flexure-based mechanisms to design industrial ultra-high precision robots, which aims at significantly reducing both the complexity of their design and their development time. This modular concept can be considered as a robotic Lego, where a finite number of building bricks is used to quickly build a high-precision robot. The core of the concept is the transformation of a 3-D design problem into several 2-D ones, which are simpler and well-mastered. This paper will first briefly present the theoretical bases of this methodology and the requirements of both types of building bricks: the active and the passive bricks. The section dedicated to the design of the active bricks will detail the current research directions, mainly the maximisation of the strokes and the development of an actuation sub-brick. As for the passive bricks, some examples will be presented, and a discussion regarding the establishment of a mechanical solution catalogue will conclude the section. Last, this modular concept will be illustrated with a practical example, consisting in the design of a 5-degree of freedom ultra-high precision robot.

  11. A Novel Gravity Compensation Method for High Precision Free-INS Based on "Extreme Learning Machine".

    Science.gov (United States)

    Zhou, Xiao; Yang, Gongliu; Cai, Qingzhong; Wang, Jing

    2016-11-29

    In recent years, with the emergency of high precision inertial sensors (accelerometers and gyros), gravity compensation has become a major source influencing the navigation accuracy in inertial navigation systems (INS), especially for high-precision INS. This paper presents preliminary results concerning the effect of gravity disturbance on INS. Meanwhile, this paper proposes a novel gravity compensation method for high-precision INS, which estimates the gravity disturbance on the track using the extreme learning machine (ELM) method based on measured gravity data on the geoid and processes the gravity disturbance to the height where INS has an upward continuation, then compensates the obtained gravity disturbance into the error equations of INS to restrain the INS error propagation. The estimation accuracy of the gravity disturbance data is verified by numerical tests. The root mean square error (RMSE) of the ELM estimation method can be improved by 23% and 44% compared with the bilinear interpolation method in plain and mountain areas, respectively. To further validate the proposed gravity compensation method, field experiments with an experimental vehicle were carried out in two regions. Test 1 was carried out in a plain area and Test 2 in a mountain area. The field experiment results also prove that the proposed gravity compensation method can significantly improve the positioning accuracy. During the 2-h field experiments, the positioning accuracy can be improved by 13% and 29% respectively, in Tests 1 and 2, when the navigation scheme is compensated by the proposed gravity compensation method.

  12. Precision of high-resolution multibeam echo sounding coupled with high-accuracy positioning in a shallow water coastal environment

    Science.gov (United States)

    Ernstsen, Verner B.; Noormets, Riko; Hebbeln, Dierk; Bartholomä, Alex; Flemming, Burg W.

    2006-09-01

    Over 4 years, repetitive bathymetric measurements of a shipwreck in the Grådyb tidal inlet channel in the Danish Wadden Sea were carried out using a state-of-the-art high-resolution multibeam echosounder (MBES) coupled with a real-time long range kinematic (LRK™) global positioning system. Seven measurements during a single survey in 2003 ( n=7) revealed a horizontal and vertical precision of the MBES system of ±20 and ±2 cm, respectively, at a 95% confidence level. By contrast, four annual surveys from 2002 to 2005 ( n=4) yielded a horizontal and vertical precision (at 95% confidence level) of only ±30 and ±8 cm, respectively. This difference in precision can be explained by three main factors: (1) the dismounting of the system between the annual surveys, (2) rougher sea conditions during the survey in 2004 and (3) the limited number of annual surveys. In general, the precision achieved here did not correspond to the full potential of the MBES system, as this could certainly have been improved by an increase in coverage density (soundings/m2), achievable by reducing the survey speed of the vessel. Nevertheless, precision was higher than that reported to date for earlier offshore test surveys using comparable equipment.

  13. High-precision comparison of the antiproton-to-proton charge-to-mass ratio

    Science.gov (United States)

    Ulmer, S.; Smorra, C.; Mooser, A.; Franke, K.; Nagahama, H.; Schneider, G.; Higuchi, T.; van Gorp, S.; Blaum, K.; Matsuda, Y.; Quint, W.; Walz, J.; Yamazaki, Y.

    2015-08-01

    Invariance under the charge, parity, time-reversal (CPT) transformation is one of the fundamental symmetries of the standard model of particle physics. This CPT invariance implies that the fundamental properties of antiparticles and their matter-conjugates are identical, apart from signs. There is a deep link between CPT invariance and Lorentz symmetry--that is, the laws of nature seem to be invariant under the symmetry transformation of spacetime--although it is model dependent. A number of high-precision CPT and Lorentz invariance tests--using a co-magnetometer, a torsion pendulum and a maser, among others--have been performed, but only a few direct high-precision CPT tests that compare the fundamental properties of matter and antimatter are available. Here we report high-precision cyclotron frequency comparisons of a single antiproton and a negatively charged hydrogen ion (H-) carried out in a Penning trap system. From 13,000 frequency measurements we compare the charge-to-mass ratio for the antiproton to that for the proton and obtain . The measurements were performed at cyclotron frequencies of 29.6 megahertz, so our result shows that the CPT theorem holds at the atto-electronvolt scale. Our precision of 69 parts per trillion exceeds the energy resolution of previous antiproton-to-proton mass comparisons as well as the respective figure of merit of the standard model extension by a factor of four. In addition, we give a limit on sidereal variations in the measured ratio of <720 parts per trillion. By following the arguments of ref. 11, our result can be interpreted as a stringent test of the weak equivalence principle of general relativity using baryonic antimatter, and it sets a new limit on the gravitational anomaly parameter of < 8.7 × 10-7.

  14. Study of axial magnetic effect

    Energy Technology Data Exchange (ETDEWEB)

    Braguta, Victor [IHEP, Protvino, Moscow region, 142284 Russia ITEP, B. Cheremushkinskaya street 25, Moscow, 117218 (Russian Federation); School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Chernodub, M. N. [CNRS, Laboratoire de Mathématiques et Physique Théorique, Université François-Rabelais Tours, Fédération Denis Poisson, Parc de Grandmont, 37200 Tours, France Department of Physics and Astronomy, University of Gent, Krijgslaan 281, S9, B-9000 Gent (Belgium); School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Goy, V. A. [School of Natural Sciences, Far Eastern Federal University, Sukhanova street 8, Vladivostok, 690950 (Russian Federation); Landsteiner, K. [Instituto de Física Teórica UAM/CSIC, C/ Nicolás Cabrera 13-15, Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid (Spain); Molochkov, A. V. [School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Ulybyshev, M. [ITEP, B. Cheremushkinskaya street 25, Moscow, 117218 Russia Institute for Theoretical Problems of Microphysics, Moscow State University, Moscow, 119899 (Russian Federation)

    2016-01-22

    The Axial Magnetic Effect manifests itself as an equilibrium energy flow of massless fermions induced by the axial (chiral) magnetic field. Here we study the Axial Magnetic Effect in the quenched SU(2) lattice gauge theory with massless overlap fermions at finite temperature. We numerically observe that in the low-temperature hadron phase the effect is absent due to the quark confinement. In the high-temperature deconfinement phase the energy flow is an increasing function of the temperature which reaches the predicted asymptotic T{sup 2} behavior at high temperatures. We find, however, that energy flow is about one order of magnitude lower compared to a theoretical prediction.

  15. Design, performance, and early results from extremely high Doppler precision instruments in a global network

    Science.gov (United States)

    Ge, Jian; Zhao, Bo; Groot, John; Chang, Liang; Varosi, Frank; Wan, Xiaoke; Powell, Scott; Jiang, Peng; Hanna, Kevin; Wang, Ji; Pais, Rohan; Liu, Jian; Dou, Liming; Schofield, Sidney; McDowell, Shaun; Costello, Erin; Delgado-Navarro, Adriana; Fleming, Scott; Lee, Brian; Bollampally, Sandeep R.; Bosman, Troy; Jakeman, Hali; Fletcher, Adam; Marquez, Gabriel

    2010-07-01

    We report design, performance and early results from two of the Extremely High Precision Extrasolar Planet Tracker Instruments (EXPERT) as part of a global network for hunting for low mass planets in the next decade. EXPERT is a combination of a thermally compensated monolithic Michelson interferometer and a cross-dispersed echelle spectrograph for extremely high precision Doppler measurements for nearby bright stars (e.g., 1m/s for a V=8 solar type star in 15 min exposure). It has R=18,000 with a 72 micron slit and a simultaneous coverage of 390-694 nm. The commissioning results show that the instrument has already produced a Doppler precision of about 1 m/s for a solar type star with S/N~100 per pixel. The instrument has reached ~4 mK (P-V) temperature stability, ~1 mpsi pressure stability over a week and a total instrument throughput of ~30% at 550 nm from the fiber input to the detector. EXPERT also has a direct cross-dispersed echelle spectroscopy mode fed with 50 micron fibers. It has spectral resolution of R=27,000 and a simultaneous wavelength coverage of 390-1000 nm.

  16. A Flexile and High Precision Calibration Method for Binocular Structured Light Scanning System

    Directory of Open Access Journals (Sweden)

    Jianying Yuan

    2014-01-01

    Full Text Available 3D (three-dimensional structured light scanning system is widely used in the field of reverse engineering, quality inspection, and so forth. Camera calibration is the key for scanning precision. Currently, 2D (two-dimensional or 3D fine processed calibration reference object is usually applied for high calibration precision, which is difficult to operate and the cost is high. In this paper, a novel calibration method is proposed with a scale bar and some artificial coded targets placed randomly in the measuring volume. The principle of the proposed method is based on hierarchical self-calibration and bundle adjustment. We get initial intrinsic parameters from images. Initial extrinsic parameters in projective space are estimated with the method of factorization and then upgraded to Euclidean space with orthogonality of rotation matrix and rank 3 of the absolute quadric as constraint. Last, all camera parameters are refined through bundle adjustment. Real experiments show that the proposed method is robust, and has the same precision level as the result using delicate artificial reference object, but the hardware cost is very low compared with the current calibration method used in 3D structured light scanning system.

  17. The high-precision videometrics methods to determining absolute vertical benchmark

    Science.gov (United States)

    Liu, Jinbo; Zhu, Zhaokun

    2013-01-01

    The mobile measurement equipment plays an important role in engineering measurement tasks and its measuring device is fixed with the vehicle platform. Therefore, how to correct the measured error in time that caused by swayed platform is a basic problem. Videometrics has its inherent advantages in solving this problem. First of all, videometrics technology is non-contact measurement, which has no effect on the target's structural characteristics and motion characteristics. Secondly, videometrics technology has high precision especially for surface targets and linear targets in the field of view. Thirdly, videometrics technology has the advantages of automatic, real-time and dynamic. This paper is mainly for mobile theodolite.etc that works under the environment of absolute vertical benchmark and proposed two high-precision methods to determine vertical benchmark: Direct-Extracting, which is based on the intersection of plats under the help of two cameras; Benchmark-Transformation, which gets the vertical benchmark by reconstructing the level-plat. Two methods both have the precision of under 10 seconds by digital simulation and physical experiments. The methods proposed by this paper have significance both on the theory and application.

  18. High precision beam momentum determination in a synchrotron using a spin resonance method

    CERN Document Server

    Goslawski, P; Gebel, R; Hartmann, M; Kacharava, A; Lehrach, A; Lorentz, B; Maier, R; Mielke, M; Papenbrock, M; Prasuhn, D; Stassen, R; Stein, H J; Stockhorst, H; Ströher, H; Wilkin, C

    2009-01-01

    In order to measure the mass of the eta meson with high accuracy using the d+p -> 3He+eta reaction, the momentum of the circulating deuteron beam in the Cooler Synchrotron COSY of the Forschungszentrum Juelich has to be determined with unprecedented precision. This has been achieved by studying the spin dynamics of the polarized deuteron beam. By depolarizing the beam through the use of an artificially induced spin resonance, it was possible to evaluate its momentum p with a precision of dp/p < 10-4 for a momentum of roughly 3 GeV/c. Different possible sources of error in the application of the spin resonance method are discussed in detail and its possible use during a standard experiment is considered.

  19. High-Precision Measurements of the Bound Electron’s Magnetic Moment

    Directory of Open Access Journals (Sweden)

    Sven Sturm

    2017-01-01

    Full Text Available Highly charged ions represent environments that allow to study precisely one or more bound electrons subjected to unsurpassed electromagnetic fields. Under such conditions, the magnetic moment (g-factor of a bound electron changes significantly, to a large extent due to contributions from quantum electrodynamics. We present three Penning-trap experiments, which allow to measure magnetic moments with ppb precision and better, serving as stringent tests of corresponding calculations, and also yielding access to fundamental quantities like the fine structure constant α and the atomic mass of the electron. Additionally, the bound electrons can be used as sensitive probes for properties of the ionic nuclei. We summarize the measurements performed so far, discuss their significance, and give a detailed account of the experimental setups, procedures and the foreseen measurements.

  20. ACADEMIC TRAINING: Probing nature with high precision; particle traps, laser spectroscopy and optical combs

    CERN Multimedia

    Françoise Benz

    2002-01-01

    17, 18, 19 June LECTURE SERIES from 11.00 to 12.00 hrs - Auditorium, bldg. 500 Probing nature with high precision; particle traps, laser spectroscopy and optical combs by G. GABRIELSE / Harvard University, USA Experiments with atomic energy scales probe nature and its symmetries with exquisite precision. Particle traps allow the manipulation of single charged particles for months at a time, allow the most accurate comparison of theory and experiment, and promise to allow better measurement of fundamental quantities like the fine structure constant. Ions and atoms can be probed with lasers that are phase locked to microwave frequency standards via optical combs, thus calibrating optical sources in terms of the official cesium second. A series of three lectures will illustrate what can be measured and discuss key techniques.  ACADEMIC TRAINING Françoise Benz Tel. 73127 francoise.benz@cern.ch

  1. Limiting Energy Dissipation Induces Glassy Kinetics in Single-Cell High-Precision Responses.

    Science.gov (United States)

    Das, Jayajit

    2016-03-08

    Single cells often generate precise responses by involving dissipative out-of-thermodynamic-equilibrium processes in signaling networks. The available free energy to fuel these processes could become limited depending on the metabolic state of an individual cell. How does limiting dissipation affect the kinetics of high-precision responses in single cells? I address this question in the context of a kinetic proofreading scheme used in a simple model of early-time T cell signaling. Using exact analytical calculations and numerical simulations, I show that limiting dissipation qualitatively changes the kinetics in single cells marked by emergence of slow kinetics, large cell-to-cell variations of copy numbers, temporally correlated stochastic events (dynamic facilitation), and ergodicity breaking. Thus, constraints in energy dissipation, in addition to negatively affecting ligand discrimination in T cells, can create a fundamental difficulty in determining single-cell kinetics from cell-population results. Copyright © 2016 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  2. Design and Manufacturing of a High-Precision Sun Tracking System Based on Image Processing

    Directory of Open Access Journals (Sweden)

    Kianoosh Azizi

    2013-01-01

    Full Text Available Concentration solar arrays require greater solar tracking precision than conventional photovoltaic arrays. This paper presents a high precision low cost dual axis sun tracking system based on image processing for concentration photovoltaic applications. An imaging device is designed according to the principle of pinhole imaging, making sun rays to be received on a screen through pinhole and to be a sun spot. The location of the spot is used to adjust the orientation of the solar panel. A fuzzy logic controller is developed to achieve this goal. A prototype was built, and experimental results have proven the good performance of the proposed system and low error of tracking. The operation of this system is independent of geographical location, initial calibration, and periodical regulations.

  3. Fast, high-precision optical polarization synthesizer for ultracold-atom experiments

    CERN Document Server

    Robens, Carsten; Alt, Wolfgang; Meschede, Dieter; Zopes, Jonathan; Alberti, Andrea

    2016-01-01

    We propose a novel approach to precisely synthesize arbitrary polarization states of light with a high modulation bandwidth. Our approach consists in superposing two laser light fields with the same wavelength, but with opposite circular polarizations, where the phase and amplitude of each light field are individually controlled. To assess the precision of the synthesized polarization states, we characterize static spatial variations of the polarization over the wavefront, as well as the noise spectral density of temporal fluctuations. We find that static polarization distortions limit the extinction ratio to $2\\times 10^{-5}$, corresponding to a 0.01% reduction of the degree of polarization (DOP). We also obtain that temporal fluctuations give rise to a $0.2^\\circ$ uncertainty in the state of polarization (SOP). We recently demonstrated an application of the polarization synthesizer (Robens et al., arXiv:1608.02410) to create two fully independent, controllable optical lattices, which trap atoms depending on...

  4. High-precision masses of neutron-deficient rubidium isotopes using a Penning trap mass spectrometer

    CERN Document Server

    Kellerbauer, A G; Beck, D; Blaum, K; Bollen, G; Guénaut, C; Herfurth, F; Herlert, A; Kluge, H J; Lunney, D; Schwarz, S; Schweikhard, L; Weber, C; Yazidjian, C

    2007-01-01

    The atomic masses of the neutron-deficient radioactive rubidium isotopes $^{74-77,79,80,83}$Rb have been measured with the Penning trap mass spectrometer ISOLTRAP. Using the time-of-flight cyclotron resonance technique, relative mass uncertainties ranging from $1.6 \\times 10^{-8}$ to $5.6 \\times 10^{-8}$ were achieved. In all cases, the mass precision was significantly improved as compared with the prior Atomic-Mass Evaluation; no significant deviations from the literature values were observed. The exotic nuclide $^{74}$Rb with a half-life of only 65 ms, is the shortest-lived nuclide on which a high-precision mass measurement in a Penning trap has been carried out. The significance of these measurements for a check of the conserved-vector-current hypothesis of the weak interaction and the unitarity of the Cabibbo-Kobayashi-Maskawa matrix is discussed.

  5. What can we learn from high precision measurements of neutrino mixing angles?

    Indian Academy of Sciences (India)

    R N Mohapatra

    2004-12-01

    Many experiments are being planned to measure the neutrino mixing angles more precisely. In this note, the theoretical significance of a high precision measurement of these parameters is discussed. It is emphasized that they can provide crucial information about different ways to understand the origin of large atmospheric neutrino mixing and move us closer towards determining the neutrino mass matrix. They may also be able to throw light on the question of lepton–quark unification as well as the existence of any leptonic symmetries. For instance if exact ↔ symmetry in the neutrino mass matrix is assumed to be the reason for maximal - mixing, one gets 13 = 0 and 13 ≃ $\\sqrt{ m^{2}_{\\odot} / m^{2}_{{\\text{A}}}$ or 13 ≃ $ m^{2}_{\\odot} / m^{2}_{{\\text{A}}}$ can provide information about the way the ↔ symmetry breaking manifests in the case of normal hierarchy.

  6. Computational Calorimetry: High-Precision Calculation of Host-Guest Binding Thermodynamics.

    Science.gov (United States)

    Henriksen, Niel M; Fenley, Andrew T; Gilson, Michael K

    2015-09-08

    We present a strategy for carrying out high-precision calculations of binding free energy and binding enthalpy values from molecular dynamics simulations with explicit solvent. The approach is used to calculate the thermodynamic profiles for binding of nine small molecule guests to either the cucurbit[7]uril (CB7) or β-cyclodextrin (βCD) host. For these systems, calculations using commodity hardware can yield binding free energy and binding enthalpy values with a precision of ∼0.5 kcal/mol (95% CI) in a matter of days. Crucially, the self-consistency of the approach is established by calculating the binding enthalpy directly, via end point potential energy calculations, and indirectly, via the temperature dependence of the binding free energy, i.e., by the van't Hoff equation. Excellent agreement between the direct and van't Hoff methods is demonstrated for both host-guest systems and an ion-pair model system for which particularly well-converged results are attainable. Additionally, we find that hydrogen mass repartitioning allows marked acceleration of the calculations with no discernible cost in precision or accuracy. Finally, we provide guidance for accurately assessing numerical uncertainty of the results in settings where complex correlations in the time series can pose challenges to statistical analysis. The routine nature and high precision of these binding calculations opens the possibility of including measured binding thermodynamics as target data in force field optimization so that simulations may be used to reliably interpret experimental data and guide molecular design.

  7. Precision mechanics

    CERN Document Server

    Kittell, David

    1989-01-01

    David Kittell, the father of the discipline, Precision Mechanics, shares the foundation of this science with you in his highly practical and fun to read book, Precision Mechanics. Based on his highly acclaimed course by the same name, first taught at the Perkin-Elmer Technical institute in Norwalk, Connecticut, and later as a short course offered in such places as Bell Labs, SPIE, IEEE, NASA, and several national labs, you will find this book relevant and immediately useful.

  8. SMILETRAP - A Penning trap facility for precision mass measurements using highly charged ions

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, I.; Carlberg, C.; Fritioff, T.; Douysset, G.; Schoenfelder, J.; Schuch, R. E-mail: schuch@physto.se

    2002-07-21

    The precision of mass measurements in a Penning trap increases linearly with the charge of the ion. Therefore we have attached a Penning trap, named SMILETRAP, to the electron beam ion source CRYSIS at MSL. CRYSIS is via an isotope separator connected to an ion source that can deliver singly charged ions of practically any element. In CRYSIS charge state breeding occurs by intense electron bombardment. We have shown that it is possible to produce, catch and measure the cyclotron frequencies of ions in the charge region 1+ to 52+. The relevant observable in mass measurements using a Penning trap is the ratio of the cyclotron frequencies of the ion of interest and ion used as a mass reference. High precision requires that the two frequencies are measured after one another in the shortest possible time. For reasons of convenience the precision trap operates at room temperature. So far it has been believed that warm traps working at 4 K are required for high mass precision with exactly one ion in the trap at a time. In this paper we demonstrate that mass precision of a few parts in 10{sup 10} also can be obtained in a warm trap at a pressure of about 5x10{sup -12} mbar by stabilizing the pressure in the He-dewar, the trap temperature and the frequency synthesizer. In order to reduce the influence of changes of the magnetic field to a level below 10{sup -10}, the scanning of the frequencies close to the resonances of both the ion of interest and the reference ion is done in a total time <2 min. Trapping of ions is a statistical procedure, allowing more than one ion to be trapped in each measurement cycle. However, after completing the measurements it is possible to reject all information except for events based on 1 and 2 trapped ions. The procedures of producing, transporting, catching, exciting and measuring the cyclotron resonance frequencies of highly charged ions and the mass reference ions with the time-of-flight method are described. In routine measurements with

  9. Correlated cryo-fluorescence and cryo-electron microscopy with high spatial precision and improved sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Schorb, Martin [Structural and Computational Biology Unit, European Molecular Biology Laboratory, D-69117 Heidelberg (Germany); Briggs, John A.G., E-mail: john.briggs@embl.de [Structural and Computational Biology Unit, European Molecular Biology Laboratory, D-69117 Heidelberg (Germany); Cell Biology and Biophysics Unit, European Molecular Biology Laboratory, D-69117 Heidelberg (Germany)

    2014-08-01

    Performing fluorescence microscopy and electron microscopy on the same sample allows fluorescent signals to be used to identify and locate features of interest for subsequent imaging by electron microscopy. To carry out such correlative microscopy on vitrified samples appropriate for structural cryo-electron microscopy it is necessary to perform fluorescence microscopy at liquid-nitrogen temperatures. Here we describe an adaptation of a cryo-light microscopy stage to permit use of high-numerical aperture objectives. This allows high-sensitivity and high-resolution fluorescence microscopy of vitrified samples. We describe and apply a correlative cryo-fluorescence and cryo-electron microscopy workflow together with a fiducial bead-based image correlation procedure. This procedure allows us to locate fluorescent bacteriophages in cryo-electron microscopy images with an accuracy on the order of 50 nm, based on their fluorescent signal. It will allow the user to precisely and unambiguously identify and locate objects and events for subsequent high-resolution structural study, based on fluorescent signals. - Highlights: • Workflow for correlated cryo-fluorescence and cryo-electron microscopy. • Cryo-fluorescence microscopy setup incorporating a high numerical aperture objective. • Fluorescent signals located in cryo-electron micrographs with 50 nm spatial precision.

  10. High-numerical-aperture cryogenic light microscopy for increased precision of superresolution reconstructions.

    Science.gov (United States)

    Nahmani, Marc; Lanahan, Conor; DeRosier, David; Turrigiano, Gina G

    2017-04-11

    Superresolution microscopy has fundamentally altered our ability to resolve subcellular proteins, but improving on these techniques to study dense structures composed of single-molecule-sized elements has been a challenge. One possible approach to enhance superresolution precision is to use cryogenic fluorescent imaging, reported to reduce fluorescent protein bleaching rates, thereby increasing the precision of superresolution imaging. Here, we describe an approach to cryogenic photoactivated localization microscopy (cPALM) that permits the use of a room-temperature high-numerical-aperture objective lens to image frozen samples in their native state. We find that cPALM increases photon yields and show that this approach can be used to enhance the effective resolution of two photoactivatable/switchable fluorophore-labeled structures in the same frozen sample. This higher resolution, two-color extension of the cPALM technique will expand the accessibility of this approach to a range of laboratories interested in more precise reconstructions of complex subcellular targets.

  11. High-precision correlative fluorescence and electron cryo microscopy using two independent alignment markers

    Energy Technology Data Exchange (ETDEWEB)

    Schellenberger, Pascale [Oxford Particle Imaging Centre, Division of Structural Biology, Wellcome Trust Centre for Human Genetics, University of Oxford, Roosevelt Drive, Oxford OX3 7BN (United Kingdom); Kaufmann, Rainer [Oxford Particle Imaging Centre, Division of Structural Biology, Wellcome Trust Centre for Human Genetics, University of Oxford, Roosevelt Drive, Oxford OX3 7BN (United Kingdom); Department of Biochemistry, University of Oxford, South Parks Road, Oxford OX1 3QU (United Kingdom); Siebert, C. Alistair; Hagen, Christoph [Oxford Particle Imaging Centre, Division of Structural Biology, Wellcome Trust Centre for Human Genetics, University of Oxford, Roosevelt Drive, Oxford OX3 7BN (United Kingdom); Wodrich, Harald [Microbiologie Fondamentale et Pathogénicité, MFP CNRS UMR 5234, University of Bordeaux SEGALEN, 146 rue Leo Seignat, 33076 Bordeaux (France); Grünewald, Kay, E-mail: kay@strubi.ox.ac.uk [Oxford Particle Imaging Centre, Division of Structural Biology, Wellcome Trust Centre for Human Genetics, University of Oxford, Roosevelt Drive, Oxford OX3 7BN (United Kingdom)

    2014-08-01

    Correlative light and electron microscopy (CLEM) is an emerging technique which combines functional information provided by fluorescence microscopy (FM) with the high-resolution structural information of electron microscopy (EM). So far, correlative cryo microscopy of frozen-hydrated samples has not reached better than micrometre range accuracy. Here, a method is presented that enables the correlation between fluorescently tagged proteins and electron cryo tomography (cryoET) data with nanometre range precision. Specifically, thin areas of vitrified whole cells are examined by correlative fluorescence cryo microscopy (cryoFM) and cryoET. Novel aspects of the presented cryoCLEM workflow not only include the implementation of two independent electron dense fluorescent markers to improve the precision of the alignment, but also the ability of obtaining an estimate of the correlation accuracy for each individual object of interest. The correlative workflow from plunge-freezing to cryoET is detailed step-by-step for the example of locating fluorescence-labelled adenovirus particles trafficking inside a cell. - Highlights: • Vitrified mammalian cell were imaged by fluorescence and electron cryo microscopy. • TetraSpeck fluorescence markers were added to correct shifts between cryo fluorescence channels. • FluoSpheres fiducials were used as reference points to assign new coordinates to cryoEM images. • Adenovirus particles were localised with an average correlation precision of 63 nm.

  12. A High-Precision NIR Survey for RV Variable Low-Mass Stars

    CERN Document Server

    Gagné, Jonathan; Gao, Peter; Anglada-Escude, Guillem; Furlan, Elise; Davison, Cassy; Tanner, Angelle; Henry, Todd J; Riedel, Adric R; Brinkworth, Carolyn; Latham, David; Bottom, Michael; White, Russel; Mills, Sean; Beichman, Chas; Johnson, John A; Ciardi, David R; Wallace, Kent; Mennesson, Bertrand; von Braun, Kaspar; Vasisht, Gautam; Prato, Lisa; Kane, Stephen R; Mamajek, Eric E; Walp, Bernie; Crawford, Timothy J; Rougeot, Raphaël; Geneser, Claire S; Catanzarite, Joseph

    2016-01-01

    We present the results of a precise near-infrared (NIR) radial velocity (RV) survey of 32 low-mass stars with spectral types K2-M4 using CSHELL at the NASA IRTF in the $K$-band with an isotopologue methane gas cell to achieve wavelength calibration and a novel iterative RV extraction method. We surveyed 14 members of young ($\\approx$ 25-150 Myr) moving groups, the young field star $\\varepsilon$ Eridani as well as 18 nearby ($<$ 25 pc) low-mass stars and achieved typical single-measurement precisions of 8-15 m s$^{-1}$ with a long-term stability of 15-50 m s$^{-1}$. We obtain the best NIR RV constraints to date on 27 targets in our sample, 19 of which were never followed by high-precision RV surveys. Our results indicate that very active stars can display long-term RV variations as low as $\\sim$ 25-50 m s$^{-1}$ at $\\approx$ 2.3125 $\\mu$m, thus constraining the effect of jitter at these wavelengths. We provide the first multi-wavelength confirmation of GJ 876 bc and independently retrieve orbital parameters...

  13. High-precision mass measurements of {sup 25}Al and {sup 30}P at JYFLTRAP

    Energy Technology Data Exchange (ETDEWEB)

    Canete, L.; Kankainen, A.; Eronen, T.; Gorelov, D.; Hakala, J.; Jokinen, A.; Kolhinen, V.S.; Koponen, J.; Moore, I.D.; Reinikainen, J.; Rinta-Antila, S. [University of Jyvaskylae (Finland)

    2016-05-15

    The masses of the astrophysically relevant nuclei {sup 25}Al and {sup 30}P have been measured with a Penning trap for the first time. The mass-excess values for {sup 25}Al (Δ=-8915.962(63) keV) and {sup 30}P (Δ=-20200.854(64) keV) obtained with the JYFLTRAP double Penning trap mass spectrometer are in good agreement with the Atomic Mass Evaluation 2012 values but ∼5-10 times more precise. A high precision is required for calculating resonant proton-capture rates of astrophysically important reactions {sup 25}Al(p,γ){sup 26}Si and {sup 30}P(p,γ){sup 31}S. In this work, Q{sub (p,γ)}=5513.99(13) keV and Q{sub (p,γ)}=6130.64(24) keV were obtained for {sup 25}Al and {sup 30}P, respectively. The effect of the more precise values on the resonant proton-capture rates has been studied. In addition to nuclear astrophysics, the measured Q{sub EC} value of {sup 25}Al, 4276.805(45) keV, is relevant for studies of T=1/2 mirror beta decays which have a potential to be used to test the Conserved Vector Current hypothesis. (orig.)

  14. High-precision astrometry with VVV. I. An independent reduction pipeline for VIRCAM@VISTA

    CERN Document Server

    Libralato, M; Bedin, L R; Anderson, J; Piotto, G; Nascimbeni, V; Platais, I; Minniti, D; Zoccali, M

    2015-01-01

    We present a new reduction pipeline for the VIRCAM@VISTA detector and describe the method developed to obtain high-precision astrometry with the VISTA Variables in the V\\'ia L\\'actea (VVV) data set. We derive an accurate geometric-distortion correction using as calibration field the globular cluster NGC 5139, and showed that we are able to reach a relative astrometric precision of about 8 mas per coordinate per exposure for well-measured stars over a field of view of more than 1 square degree. This geometric-distortion correction is made available to the community. As a test bed, we chose a field centered around the globular cluster NGC 6656 from the VVV archive and computed proper motions for the stars within. With 45 epochs spread over four years, we show that we are able to achieve a precision of 1.4 mas/yr and to isolate each population observed in the field (cluster, Bulge and Disk) using proper motions. We used proper-motion-selected field stars to measure the motion difference between Galactic disk and...

  15. A high precision visual localization sensor and its working methodology for an indoor mobile robot

    Institute of Scientific and Technical Information of China (English)

    Feng-yu ZHOU; Xian-feng YUAN; Yang YANG; Zhi-fei JIANG; Chen-lei ZHOU

    2016-01-01

    To overcome the shortcomings of existing robot localization sensors, such as low accuracy and poor robustness, a high precision visual localization system based on infrared-reflective artificial markers is designed and illustrated in detail in this paper. First, the hardware system of the localization sensor is developed. Secondly, we design a novel kind of infrared-reflective artificial marker whose characteristics can be extracted by the acquisition and processing of the infrared image. In addition, a confidence calculation method for marker identification is proposed to obtain the probabilistic localization results. Finally, the autonomous localization of the robot is achieved by calculating the relative pose relation between the robot and the artificial marker based on the perspective-3-point (P3P) visual localization algorithm. Numerous experiments and practical applications show that the designed localization sensor system is immune to the interferences of the illumination and observation angle changes. The precision of the sensor is ±1.94 cm for position localization and ±1.64◦ for angle localization. Therefore, it satisfies perfectly the requirements of localization precision for an indoor mobile robot.

  16. Build Axial Gradient Field by Using Axial Magnetized Permanent Rings

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Axial magnetic field produced by an axial magnetized permanent ring was studied. For two permanent rings, if they are magnetized in the same directions, a nearly uniform axial field can be produced. If they are magnetized in opposite direction,an axial gradient magnetic field can be generated, with the field range changing from -B0 to B0. A permanent magnet with a high axial gradient field was fabricated, the measured results agree with the PANDIRA calculation very well. For wider usage,it is desirable for the field gradient to be changed. Some methods to produce the variable gradient field are presented. These kinds of axial gradient magnetic field can also be used as a beam focusing for linear accelerator if the periodic field can be produced along the beam trajectory. The axial magnetic field is something like a solenoid, large stray field will leak to the outside environment if no method is taken to control them. In this paper, one method is illustrated to shield off the outside leakage field.

  17. Multifrequency high precise subTHz-THz-IR spectroscopy for exhaled breath research

    Science.gov (United States)

    Vaks, Vladimir L.; Domracheva, Elena G.; Pripolzin, Sergey I.; Chernyaeva, Mariya B.

    2016-09-01

    Nowadays the development of analytical spectroscopy with high performance, sensitivity and spectral resolution for exhaled breath research is attended. The method of two-frequency high precise THz spectroscopy and the method of high precise subTHz-THz-IR spectroscopy are presented. Development of a subTHz-THz-IR gas analyzer increases the number of gases that can be identified and the reliability of the detection by confirming the signature in both THz and MIR ranges. The testing measurements have testified this new direction of analytical spectroscopy to open widespread trends of its using for various problems of medicine and biology. First of all, there are laboratory investigations of the processes in exhaled breath and studying of their dynamics. Besides, the methods presented can be applied for detecting intermediate and short time living products of reactions in exhaled breath. The spectrometers have been employed for investigations of acetone, methanol and ethanol in the breath samples of healthy volunteers and diabetes patients. The results have demonstrated an increased concentration of acetone in breath of diabetes patients. The dynamic of changing the acetone concentration before and after taking the medicines is discovered. The potential markers of pre-cancer states and oncological diseases of gastrointestinal tract organs have been detected. The changes in the NO concentration in exhaled breath of cancer patients during radiotherapy as well as increase of the NH3 concentration at gastrointestinal diseases have been revealed. The preliminary investigations of biomarkers in three frequency ranges have demonstrated the advantages of the multifrequency high precise spectroscopy for noninvasive medical diagnostics.

  18. Proceedings, High-Precision $\\alpha_s$ Measurements from LHC to FCC-ee

    Energy Technology Data Exchange (ETDEWEB)

    d' Enterria, David [CERN; Skands, Peter Z. [Monash U.

    2015-01-01

    This document provides a writeup of all contributions to the workshop on "High precision measurements of $\\alpha_s$: From LHC to FCC-ee" held at CERN, Oct. 12--13, 2015. The workshop explored in depth the latest developments on the determination of the QCD coupling $\\alpha_s$ from 15 methods where high precision measurements are (or will be) available. Those include low-energy observables: (i) lattice QCD, (ii) pion decay factor, (iii) quarkonia and (iv) $\\tau$ decays, (v) soft parton-to-hadron fragmentation functions, as well as high-energy observables: (vi) global fits of parton distribution functions, (vii) hard parton-to-hadron fragmentation functions, (viii) jets in $e^\\pm$p DIS and $\\gamma$-p photoproduction, (ix) photon structure function in $\\gamma$-$\\gamma$, (x) event shapes and (xi) jet cross sections in $e^+e^-$ collisions, (xii) W boson and (xiii) Z boson decays, and (xiv) jets and (xv) top-quark cross sections in proton-(anti)proton collisions. The current status of the theoretical and experimental uncertainties associated to each extraction method, the improvements expected from LHC data in the coming years, and future perspectives achievable in $e^+e^-$ collisions at the Future Circular Collider (FCC-ee) with $\\cal{O}$(1--100 ab$^{-1}$) integrated luminosities yielding 10$^{12}$ Z bosons and jets, and 10$^{8}$ W bosons and $\\tau$ leptons, are thoroughly reviewed. The current uncertainty of the (preliminary) 2015 strong coupling world-average value, $\\alpha_s(m_Z)$ = 0.1177 $\\pm$ 0.0013, is about 1\\%. Some participants believed this may be reduced by a factor of three in the near future by including novel high-precision observables, although this opinion was not universally shared. At the FCC-ee facility, a factor of ten reduction in the $\\alpha_s$ uncertainty should be possible, mostly thanks to the huge Z and W data samples available.

  19. A high precision method for quantitative measurements of reactive oxygen species in frozen biopsies.

    Directory of Open Access Journals (Sweden)

    Kirsti Berg

    Full Text Available OBJECTIVE: An electron paramagnetic resonance (EPR technique using the spin probe cyclic hydroxylamine 1-hydroxy-3-methoxycarbonyl-2,2,5,5-tetramethylpyrrolidine (CMH was introduced as a versatile method for high precision quantification of reactive oxygen species, including the superoxide radical in frozen biological samples such as cell suspensions, blood or biopsies. MATERIALS AND METHODS: Loss of measurement precision and accuracy due to variations in sample size and shape were minimized by assembling the sample in a well-defined volume. Measurement was carried out at low temperature (150 K using a nitrogen flow Dewar. The signal intensity was measured from the EPR 1st derivative amplitude, and related to a sample, 3-carboxy-proxyl (CP• with known spin concentration. RESULTS: The absolute spin concentration could be quantified with a precision and accuracy better than ±10 µM (k = 1. The spin concentration of samples stored at -80°C could be reproduced after 6 months of storage well within the same error estimate. CONCLUSION: The absolute spin concentration in wet biological samples such as biopsies, water solutions and cell cultures could be quantified with higher precision and accuracy than normally achievable using common techniques such as flat cells, tissue cells and various capillary tubes. In addition; biological samples could be collected and stored for future incubation with spin probe, and also further stored up to at least six months before EPR analysis, without loss of signal intensity. This opens for the possibility to store and transport incubated biological samples with known accuracy of the spin concentration over time.

  20. Maintaining high precision of isotope ratio analysis over extended periods of time.

    Science.gov (United States)

    Brand, Willi A

    2009-06-01

    Stable isotope ratios are reliable and long lasting process tracers. In order to compare data from different locations or different sampling times at a high level of precision, a measurement strategy must include reliable traceability to an international stable isotope scale via a reference material (RM). Since these international RMs are available in low quantities only, we have developed our own analysis schemes involving laboratory working RM. In addition, quality assurance RMs are used to control the long-term performance of the delta-value assignments. The analysis schemes allow the construction of quality assurance performance charts over years of operation. In this contribution, the performance of three typical techniques established in IsoLab at the MPI-BGC in Jena is discussed. The techniques are (1) isotope ratio mass spectrometry with an elemental analyser for delta(15)N and delta(13)C analysis of bulk (organic) material, (2) high precision delta(13)C and delta(18)O analysis of CO(2) in clean-air samples, and (3) stable isotope analysis of water samples using a high-temperature reaction with carbon. In addition, reference strategies on a laser ablation system for high spatial resolution delta(13)C analysis in tree rings is exemplified briefly.

  1. A Study of the Merits of Precision Time Protocol (IEEE-1588) Across High-Speed Data Networks

    CERN Document Server

    Oliver, David; Otto, Adam Jedrzej; CERN. Geneva. PH Department

    2015-01-01

    By using Precision Time Protocol across high-speed data networks, it is possible to achieve good time synchronisation using only commercial, off-the-shelve equipment. Even under heavy network loads, the attainable precision far exceeds that which is possible with Network Time Protocol, and is sufficient for many applications. This note explores the time precision possible with PTP under various conditions and attempts to provide a measurement of its performance.

  2. A Study of the Merits of Precision Time Protocol (IEEE-1588) Across High-Speed Data Networks

    CERN Document Server

    Oliver, David; Neufeld, Niko

    2015-01-01

    By using Precision Time Protocol across high-speed data networks, it is possible to achieve good time synchronisation without requiring the use of custom switches. Even under heavy network loads, the attainable precision far exceeds that which is possible with Network Time Protocol, and is sufficient for many applications. This note explores the attainable precision possible with PTP under various conditions and attempts to provide a measurement of its performance.

  3. High-precision Distribution of Highly-stable Optical Pulse Trains with Sub-10-fs Timing Jitter

    CERN Document Server

    Ning, B; Hou, D; Wu, J T; Li, Z B; Zhao, J Y

    2014-01-01

    High-precision optical pulse trains distribution via fibre links has made huge impacts in many fields. In most published works, the accuracies are still fundamentally limited by some unavoidable noises, such as thermal and shot noise from conventional photodiodes, thermal noise from mixers. Here, we demonstrate a new high-precision timing distribution system by using highly-precision phase detector to overcome the limitations. Instead of using photodiodes and microwave mixers, we use several fibre Sagnac-loop-based optical-microwave phase detectors to realize optical-electrical conversion and phase measurements, for suppressing the noises and achieving ultra-high accuracy. A 10-km fibre link distribution experiment shows our system provides a residual instability at the level of 4.6*10-15@1-s and 6.1*10-18@10000-s, with an integrated timing jitter as low as 3.8 fs in a bandwidth of 1 Hz to 100 KHz. This low instability and timing jitter makes it possible that our system can be used in the optical clock distri...

  4. An optical fan for light beams for high-precision optical measurements and optical switching

    CERN Document Server

    Zhou, Zhi-Yuan; Ding, Dong-Sheng; Jiang, Yun-Kun; Zhang, Wei; Shi, Shuai; Shi, Bao-Sen; Guo, Guang-Can

    2014-01-01

    The polarization and orbital angular momentum properties of light are of great importance in optical science and technology in the fields of high precision optical measurements and high capacity and high speed optical communications. Here we show, a totally new method, based on a combination of these two properties and using the thermal dispersion and electro-optical effect of birefringent crystals, the construction of a simple and robust scheme to rotate a light beam like a fan. Using a computer-based digital image processing technique, we determine the temperature and the thermal dispersion difference of the crystal with high resolution. We also use the rotation phenomenon to realize thermo-optic and electro-optic switches. The basic operating principles for measurement and switching processes are presented in detail. The methods developed here will have wide practical applicability in various fields, including remote sensing, materials science and optical communication networks.

  5. An efficient, compact, and versatile fiber double scrambler for high precision radial velocity instruments

    CERN Document Server

    Halverson, Samuel; Mahadevan, Suvrath; Ramsey, Lawrence; Levi, Eric; Schwab, Christian; Hearty, Fred; MacDonald, Nick

    2015-01-01

    We present the design and test results of a compact optical fiber double-scrambler for high-resolution Doppler radial velocity instruments. This device consists of a single optic: a high-index $n$$\\sim$2 ball lens that exchanges the near and far fields between two fibers. When used in conjunction with octagonal fibers, this device yields very high scrambling gains and greatly desensitizes the fiber output from any input illumination variations, thereby stabilizing the instrument profile of the spectrograph and improving the Doppler measurement precision. The system is also highly insensitive to input pupil variations, isolating the spectrograph from telescope illumination variations and seeing changes. By selecting the appropriate glass and lens diameter the highest efficiency is achieved when the fibers are practically in contact with the lens surface, greatly simplifying the alignment process when compared to classical double-scrambler systems. This prototype double-scrambler has demonstrated significant pe...

  6. Devices for high precision x-ray beam intensity monitoring on BSRF

    CERN Document Server

    Hua-Peng, LI; Zhao, Yi-Dong; Zheng, Lei; Liu, Shu-Hu; Zhao, Xiao-Liang; Zhao, Ya-Shuai

    2016-01-01

    Synchrotron radiation with the characteristic of high brilliance, high level of polarization, high collimation, low emittance and wide tunability in energy has been used as a standard source in metrology(1, 2). For a decade, lots of calibration work have been done on 4B7A in Beijing Synchrotron Radiation Facility (BSRF) (3, 4). For the calibration process, a high-precision online monitor is indispensable. To control the uncertainty under 0.1%, we studied different sizes parallel ion chambers with rare-gas and used different collecting methods to monitor the x-ray intensity of the beamline. Two methods to collect the signal of the ion chambers: reading the current directly with electrometer or signal amplification to collect the counts were compared.

  7. A new type of tri-axial accelerometers with high dynamic range MEMS for earthquake early warning

    Science.gov (United States)

    Peng, Chaoyong; Chen, Yang; Chen, Quansheng; Yang, Jiansi; Wang, Hongti; Zhu, Xiaoyi; Xu, Zhiqiang; Zheng, Yu

    2017-03-01

    Earthquake Early Warning System (EEWS) has shown its efficiency for earthquake damage mitigation. As the progress of low-cost Micro Electro Mechanical System (MEMS), many types of MEMS-based accelerometers have been developed and widely used in deploying large-scale, dense seismic networks for EEWS. However, the noise performance of these commercially available MEMS is still insufficient for weak seismic signals, leading to the large scatter of early-warning parameters estimation. In this study, we developed a new type of tri-axial accelerometer based on high dynamic range MEMS with low noise level using for EEWS. It is a MEMS-integrated data logger with built-in seismological processing. The device is built on a custom-tailored Linux 2.6.27 operating system and the method for automatic detecting seismic events is STA/LTA algorithms. When a seismic event is detected, peak ground parameters of all data components will be calculated at an interval of 1 s, and τc-Pd values will be evaluated using the initial 3 s of P wave. These values will then be organized as a trigger packet actively sent to the processing center for event combining detection. The output data of all three components are calibrated to sensitivity 500 counts/cm/s2. Several tests and a real field test deployment were performed to obtain the performances of this device. The results show that the dynamic range can reach 98 dB for the vertical component and 99 dB for the horizontal components, and majority of bias temperature coefficients are lower than 200 μg/°C. In addition, the results of event detection and real field deployment have shown its capabilities for EEWS and rapid intensity reporting.

  8. Resolving high precision U-Pb ages from Tertiary plutons with complex zircon systematics

    Science.gov (United States)

    Mcclelland, William C.; Mattinson, James M.

    1996-10-01

    Success in establishing high precision crystallization ages with the U/Pb zircon method is highly dependent on the ability to isolate or remove the effects of inherited xenocrystic components or secondary lead-loss, or the combined effects of both. Current "conventional" single crystal and ion probe (SHRIMP) methods are successfully applied to Paleozoic and older samples but typically suffer from imprecision when applied to younger (Mesozoic-Cenozoic) samples due to generally reduced radiogenic lead concentrations. Here we apply a series of intense partial dissolution steps to multigrain zircon fractions from a series of Paleocene tonalitic to granodioritic intrusive rocks from southeastern Alaska. The zircon systematics are complicated by both minor inheritance and postcrystallization lead-loss. Physical and isotopic evidence demonstrate that the partial dissolution steps preferentially remove outer layers susceptible to lead loss, as well as core regions containing inherited components. The final residues are often hollow shells of low-U primary igneous zircon that yield highly precise, reproducible, and concordant ages. The resulting age determinations commonly statistically differ at the 95% confidence level from ages based on apparently concordant, but less precise conventional isotope dilution analyses, the uncertainties of which masked minor, subtle isotopic complexities. This observation strongly cautions against basing age assignments of samples yielding slightly discordant data on (1) single "concordant" analyses accompanied by an array of discordant data or (2) the mean of several 206Pb/ 238U or 207Pb/ 206Pb ages. The step-wise dissolution technique allows age determinations on young, relatively low U and Pb zircons at a resolution not currently possible with techniques such as single-grain conventional or spot ion probe analyses. Widespread application of the technique will likely prove instrumental in resolving detailed magmatic histories of igneous

  9. High-Precision Dispensing of Nanoliter Biofluids on Glass Pedestal Arrays for Ultrasensitive Biomolecule Detection.

    Science.gov (United States)

    Chen, Xiaoxiao; Liu, Yang; Xu, QianFeng; Zhu, Jing; Poget, Sébastien F; Lyons, Alan M

    2016-05-04

    Precise dispensing of nanoliter droplets is necessary for the development of sensitive and accurate assays, especially when the availability of the source solution is limited. Conventional approaches are limited by imprecise positioning, large shear forces, surface tension effects, and high costs. To address the need for precise and economical dispensing of nanoliter volumes, we developed a new approach where the dispensed volume is dependent on the size and shape of defined surface features, thus freeing the dispensing process from pumps and fine-gauge needles requiring accurate positioning. The surface we fabricated, called a nanoliter droplet virtual well microplate (nVWP), achieves high-precision dispensing (better than ±0.5 nL or ±1.6% at 32 nL) of 20-40 nL droplets using a small source drop (3-10 μL) on isolated hydrophilic glass pedestals (500 μm on a side) bonded to arrays of polydimethylsiloxane conical posts. The sharp 90° edge of the glass pedestal pins the solid-liquid-vapor triple contact line (TCL), averting the wetting of the glass sidewalls while the fluid is prevented from receding from the edge. This edge creates a sufficiently large energy barrier such that microliter water droplets can be poised on the glass pedestals, exhibiting contact angles greater >150°. This approach relieves the stringent mechanical alignment tolerances required for conventional dispensing techniques, shifting the control of dispensed volume to the area circumscribed by the glass edge. The effects of glass surface chemistry and dispense velocity on droplet volume were studied using optical microscopy and high-speed video. Functionalization of the glass pedestal surface enabled the selective adsorption of specific peptides and proteins from synthetic and natural biomolecule mixtures, such as venom. We further demonstrate how the nVWP dispensing platform can be used for a variety of assays, including sensitive detection of proteins and peptides by fluorescence

  10. Overview of the JYFLTRAP mass measurements and high-precision -values for weak interaction studies

    Indian Academy of Sciences (India)

    T Eronen; Jyfltrap

    2010-08-01

    The JYFLTRAP Penning trap set-up at the University of Jyväskylä, Finland, is a Penning trap facility that has provided high-precision atomic mass values for short-lived nuclides since 2003. Until now, masses of more than 250 short-lived nuclides have been measured. Since JYFLTRAP is coupled to the chemically insensitive IGISOL mass separator, any element can be accessed. So far, a huge mass surface extending from magnesium ( = 12) to lead ( = 82) has been covered.

  11. [Physiological and hygienic characteristic of high-precision manufacturing operations in microelectronics].

    Science.gov (United States)

    Kirillov, V F; Mironov, A I; Gadakchan, K A; Mekhova, M M; Spiridonova, V S

    2010-01-01

    It was shown that workers performing high-precision manufacturing operations in microelectronic industry undergo severe visual, nervous and emotional stress combined with significant locomotor load, air deionization and deozonation, bacterial contamination, and UV deficit at their workplaces. These working conditions promote development of negative changes in the visual analyzer, nervous and emotional disorders, disturbances of systemic and regional hemodynamics. Also impaired is the functional state of the upper limb neuromuscular apparatus, central nervous and cardiovascular systems. The proposed certified complex of organizational, sanitary, hygienic, physiological, ergonomic, therapeutic and preventive measures has positive influence on the working capacity of employees in microelectronic industry.

  12. Precise Access to the Molecular-Frame Complex Recombination Dipole through High-Harmonic Spectroscopy

    Science.gov (United States)

    Schoun, S. B.; Camper, A.; Salières, P.; Lucchese, R. R.; Agostini, P.; DiMauro, L. F.

    2017-01-01

    We report on spectral intensity and group delay measurements of the highest-occupied molecular-orbital (HOMO) recombination dipole moment of N2 in the molecular-frame using high harmonic spectroscopy. We take advantage of the long-wavelength 1.3 μ m driving laser to isolate the HOMO in the near threshold region, 19-67 eV. The precision of our group delay measurements reveals previously unseen angle-resolved spectral features associated with autoionizing resonances, and allows quantitative comparison with cutting-edge correlated 8-channel photoionization dipole moment calculations.

  13. A High-Precision Forecasting Model and Its Constructing Method for Vein-Type Gold Deposits

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A high-precision forecasting and prospecting model incorporating the “field theory-field structure analysis-field simulation”, a temporal and spatial structural framework reflecting local extremely fine structures, is established to make an effective extraction and an integrated analysis of multivariate forecasting information. This model can best show not only the coupling between metallogenic anomalous structure, mineralized structure and information structure, but also the extraction, optimization, matching and summarization of key forecasting information. The technological keys to this model are the fine structural analysis of geological and geophysical and geochemical anomalous fields and metallogenic fields, and the establishment of occurrence patterns for the spatial location of orebodies.

  14. On the recovery of gravity anomalies from high precision altimeter data

    Science.gov (United States)

    Lelgemann, D.

    1976-01-01

    A model for the recovery of gravity anomalies from high precision altimeter data is derived which consists of small correction terms to the inverse Stokes' formula. The influence of unknown sea surface topography in the case of meandering currents such as the Gulf Stream is discussed. A formula was derived in order to estimate the accuracy of the gravity anomalies from the known accuracy of the altimeter data. It is shown that for the case of known harmonic coefficients of lower order the range of integration in Stokes inverse formula can be reduced very much.

  15. High-precision gas gain and energy transfer measurements in Ar–CO{sub 2} mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Şahin, Özkan, E-mail: osahin@uludag.edu.tr [Department of Physics, Uludağ University, 16059 Bursa (Turkey); Kowalski, Tadeusz Z. [Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Kraków (Poland); Veenhof, Rob [Department of Physics, Uludağ University, 16059 Bursa (Turkey); RD51 collaboration, CERN, Genève (Switzerland)

    2014-12-21

    Ar–CO{sub 2} is a Penning mixture since a fraction of the energy stored in Ar 3p{sup 5}3d and higher excited states can be transferred to ionize CO{sub 2} molecules. In the present work, concentration and pressure dependence of Penning transfer rate and photon feedback parameter in Ar–CO{sub 2} mixtures have been investigated with recent systematic high-precision gas gain measurements which cover the range 1–50% CO{sub 2} at 400, 800, 1200, 1800 hPa and gas gain from 1 to 5×10{sup 5}.

  16. High precision measurement of the associated strangeness production in proton proton interactions

    CERN Document Server

    :,; Borodina, E; Clement, H; Doroshkevich, E; Dzhygadlo, R; Ehrhardt, K; Eyrich, W; Gast, W; Gillitzer, A; Grzonka, D; Hauenstein, F; Klaja, P; Kober, L; Kilian, K; Krapp, M; Mertens, M; Moskal, P; Ritman, J; Roderburg, E; Röder, M; Schroeder, W; Sefzick, T; Smyrski, J; Wintz, P; Wüstner, P

    2016-01-01

    A new high precision measurement of the reaction pp -> pK+Lambda at a beam momentum of 2.95 GeV/c with more than 200,000 analyzed events allows a detailed analysis of differential observables and their inter-dependencies. Correlations of the angular distributions with momenta are examined. The invariant mass distributions are compared for different regions in the Dalitz plots. The cusp structure at the N Sigma threshold is described with the Flatt\\'e formalism and its variation in the Dalitz plot is analyzed.

  17. High-precision measurement of the associated strangeness production in proton-proton interactions

    Energy Technology Data Exchange (ETDEWEB)

    Jowzaee, S. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Jagellonian University, Institute of Physics, Cracow (Poland); Borodina, E.; Dzhygadlo, R.; Gast, W.; Gillitzer, A.; Grzonka, D.; Kilian, K.; Mertens, M.; Roderburg, E.; Roeder, M.; Sefzick, T.; Wintz, P. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Clement, H. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Erlangen (Germany); University of Tuebingen, Kepler Center for Astro and Particle Physics, Tuebingen (Germany); Doroshkevich, E.; Ehrhardt, K. [Physikalisches Institut der Universitaet Tuebingen, Tuebingen (Germany); University of Tuebingen, Kepler Center for Astro and Particle Physics, Tuebingen (Germany); Eyrich, W.; Kober, L.; Krapp, M. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Erlangen (Germany); Hauenstein, F.; Klaja, P. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Erlangen (Germany); Moskal, P.; Smyrski, J. [Jagellonian University, Institute of Physics, Cracow (Poland); Ritman, J. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Forces and Matter Experiments (JARA-FAME), Juelich Aachen Research Allianz, Juelich (Germany); Ruhr-Universitaet Bochum, Experimentalphysik I, Bochum (Germany); Schroeder, W. [Forschungszentrum Juelich, Corporate Development, Juelich (Germany); Wuestner, P. [Elektronik und Analytik, Zentralinstitut fuer Engineering, Juelich (Germany); Collaboration: The COSY-TOF Collaboration

    2016-01-15

    A new high-precision measurement of the reaction pp → pK{sup +}Λ at a beam momentum of 2.95 GeV/c with more than 200 000 analyzed events allows a detailed analysis of differential observables and their inter-dependencies. Correlations of the angular distributions with momenta are examined. The invariant mass distributions are compared for different regions in the Dalitz plots. The cusp structure at the NΣ threshold is described with the Flatte formalism and its variation in the Dalitz plot is analyzed. (orig.)

  18. High-precision measurement of the associated strangeness production in proton-proton interactions

    Science.gov (United States)

    Jowzaee, S.; Borodina, E.; Clement, H.; Doroshkevich, E.; Dzhygadlo, R.; Ehrhardt, K.; Eyrich, W.; Gast, W.; Gillitzer, A.; Grzonka, D.; Hauenstein, F.; Klaja, P.; Kober, L.; Kilian, K.; Krapp, M.; Mertens, M.; Moskal, P.; Ritman, J.; Roderburg, E.; Röder, M.; Schroeder, W.; Sefzick, T.; Smyrski, J.; Wintz, P.; Wüstner, P.

    2016-01-01

    A new high-precision measurement of the reaction pp→ pK+Λ at a beam momentum of 2.95 GeV/ c with more than 200 000 analyzed events allows a detailed analysis of differential observables and their inter-dependencies. Correlations of the angular distributions with momenta are examined. The invariant mass distributions are compared for different regions in the Dalitz plots. The cusp structure at the NΣ threshold is described with the Flatté formalism and its variation in the Dalitz plot is analyzed.

  19. Mechanical optimisation of a high-precision fast wire scanner at CERN

    CERN Document Server

    Samuelsson, Sebastian; Veness, Raymond

    Wire scanners are instruments used to measure the transverse beam prole in particle accelerators by passing a thin wire through the particle beam. To avoid the issues of vacuum leakage through the bellows and wire failure related to current designs of wire scanners, a new concept for a wire scanner has been developed at CERN. This design has all moving parts inside the beam vacuum and has a nominal wire scanning speed of 20 m/s. The demands on the design associated with this together with the high precision requirements create a need for\

  20. High-precision gas gain and energy transfer measurements in Ar–CO2 mixtures

    CERN Document Server

    Şahin, Özkan; Veenhof, Rob

    2014-01-01

    Ar–CO2 is a Penning mixture since a fraction of the energy stored in Ar 3p53d3p53d and higher excited states can be transferred to ionize CO2 molecules. In the present work, concentration and pressure dependence of Penning transfer rate and photon feedback parameter in Ar–CO2 mixtures have been investigated with recent systematic high-precision gas gain measurements which cover the range 1–50% CO2 at 400, 800, 1200, 1800 hPa and gas gain from 1 to 5×105.

  1. High Precision Temperature Control and Analysis of RF Deionized Cooling Water System

    CERN Document Server

    Tsai, Zong-Da; Chen June Rong; Liu, Chen-Yao

    2005-01-01

    Previously, the Taiwan Light Source (TLS) has proven the good beam quality mainly depends on the utility system stability. A serial of efforts were devoted to these studies. Further, a high precision temperature control of the RF deionized cooling water system will be achieved to meet the more critical stability requirement. The paper investigates the mixing mechanism through thermal and flow analysis and verifies the practical influences. A flow mixing mechanism and control philosophy is studied and processed to optimize temperature variation which has been reduced from ±0.1? to ±0.01?. Also, the improvement of correlation between RF performance and water cooling stability will be presented.

  2. Practical analysis of high purity chemicals--V. Precision silver chloride gravimetry.

    Science.gov (United States)

    Little, K

    1971-09-01

    A reasonably simple gravimetric silver chloride procedure with fairly wide tolerance in conditions is presented in full detail with all critical steps and precautions delineated. The procedure allows the precision determination of chloride by analysts having limited expertise with exacting gravimetric methods, and can be performed with equipment common to nearly all laboratories and without dependence on a standard substance. The elapsed and actual working times for the assessment of a solid sample in triplicate are 65 and 10-12 hr respectively. The application of the procedure to the assay of some high-purity chloride salts and to the standardization of hydrochloric acid solutions is described.

  3. A high current pulsed power generator CQ-3-MMAF with co-axial cable transmitting energy for material dynamics experiments

    Science.gov (United States)

    Wang, Guiji; Chen, Xuemiao; Cai, Jintao; Zhang, Xuping; Chong, Tao; Luo, Binqiang; Zhao, Jianheng; Sun, Chengwei; Tan, Fuli; Liu, Cangli; Wu, Gang

    2016-06-01

    A high current pulsed power generator CQ-3-MMAF (Multi-Modules Assembly Facility, MMAF) was developed for material dynamics experiments under ramp wave and shock loadings at the Institute of Fluid Physics (IFP), which can deliver 3 MA peak current to a strip-line load. The rise time of the current is 470 ns (10%-90%). Different from the previous CQ-4 at IFP, the CQ-3-MMAF energy is transmitted by hundreds of co-axial high voltage cables with a low impedance of 18.6 mΩ and low loss, and then hundreds of cables are reduced and converted to tens of cables into a vacuum chamber by a cable connector, and connected with a pair of parallel metallic plates insulated by Kapton films. It is composed of 32 capacitor and switch modules in parallel. The electrical parameters in short circuit are with a capacitance of 19.2 μF, an inductance of 11.7 nH, a resistance of 4.3 mΩ, and working charging voltage of 60 kV-90 kV. It can be run safely and stable when charged from 60 kV to 90 kV. The vacuum of loading chamber can be up to 10-2 Pa, and the current waveforms can be shaped by discharging in time sequences of four groups of capacitor and switch modules. CQ-3-MMAF is an adaptive machine with lower maintenance because of its modularization design. The COMSOL Multi-physics® code is used to optimize the structure of some key components and calculate their structural inductance for designs, such as gas switches and cable connectors. Some ramp wave loading experiments were conducted to check and examine the performances of CQ-3-MMAF. Two copper flyer plates were accelerated to about 3.5 km/s in one shot when the working voltage was charged to 70 kV. The velocity histories agree very well. The dynamic experiments of some polymer bonded explosives and phase transition of tin under ramp wave loadings were also conducted. The experimental data show that CQ-3-MMAF can be used to do material dynamics experiments in high rate and low cost shots. Based on this design concept, the peak

  4. A high current pulsed power generator CQ-3-MMAF with co-axial cable transmitting energy for material dynamics experiments.

    Science.gov (United States)

    Wang, Guiji; Chen, Xuemiao; Cai, Jintao; Zhang, Xuping; Chong, Tao; Luo, Binqiang; Zhao, Jianheng; Sun, Chengwei; Tan, Fuli; Liu, Cangli; Wu, Gang

    2016-06-01

    A high current pulsed power generator CQ-3-MMAF (Multi-Modules Assembly Facility, MMAF) was developed for material dynamics experiments under ramp wave and shock loadings at the Institute of Fluid Physics (IFP), which can deliver 3 MA peak current to a strip-line load. The rise time of the current is 470 ns (10%-90%). Different from the previous CQ-4 at IFP, the CQ-3-MMAF energy is transmitted by hundreds of co-axial high voltage cables with a low impedance of 18.6 mΩ and low loss, and then hundreds of cables are reduced and converted to tens of cables into a vacuum chamber by a cable connector, and connected with a pair of parallel metallic plates insulated by Kapton films. It is composed of 32 capacitor and switch modules in parallel. The electrical parameters in short circuit are with a capacitance of 19.2 μF, an inductance of 11.7 nH, a resistance of 4.3 mΩ, and working charging voltage of 60 kV-90 kV. It can be run safely and stable when charged from 60 kV to 90 kV. The vacuum of loading chamber can be up to 10(-2) Pa, and the current waveforms can be shaped by discharging in time sequences of four groups of capacitor and switch modules. CQ-3-MMAF is an adaptive machine with lower maintenance because of its modularization design. The COMSOL Multi-physics® code is used to optimize the structure of some key components and calculate their structural inductance for designs, such as gas switches and cable connectors. Some ramp wave loading experiments were conducted to check and examine the performances of CQ-3-MMAF. Two copper flyer plates were accelerated to about 3.5 km/s in one shot when the working voltage was charged to 70 kV. The velocity histories agree very well. The dynamic experiments of some polymer bonded explosives and phase transition of tin under ramp wave loadings were also conducted. The experimental data show that CQ-3-MMAF can be used to do material dynamics experiments in high rate and low cost shots. Based on this design concept, the peak

  5. Dynamic Response of RPC-Filled Steel Tubular Columns with High Load Carrying Capacity Under Axial Impact Loading

    Institute of Scientific and Technical Information of China (English)

    TIAN Zhimin; WU Ping'an; JIA Jianwei

    2008-01-01

    Experimental investigation into impact-resistant behavior of reactive powder concrete (RPC)-filled steel tubular columns was conducted, and dynamic response of the columns under axial impact loading was studied by means of numerical simulation method.Increase coefficient of load carrying capacity and ratio of load carrying capacity between steel tube and RPC core of columns were obtained.

  6. High-precision photometry by telescope defocussing. VII. The ultra-short period planet WASP-103

    CERN Document Server

    Southworth, John; Ciceri, S; Budaj, J; Dominik, M; Jaimes, R Figuera; Haugbolle, T; Jorgensen, U G; Popovas, A; Rabus, M; Rahvar, S; von Essen, C; Schmidt, R W; Wertz, O; Alsubai, K A; Bozza, V; Bramich, D M; Novati, S Calchi; D'Ago, G; Hinse, T C; Henning, Th; Hundertmark, M; Juncher, D; Korhonen, H; Skottfelt, J; Snodgrass, C; Starkey, D; Surdej, J

    2014-01-01

    We present 17 transit light curves of the ultra-short period planetary system WASP-103, a strong candidate for the detection of tidally-induced orbital decay. We use these to establish a high-precision reference epoch for transit timing studies. The time of the reference transit midpoint is now measured to an accuracy of 4.8s, versus 67.4s in the discovery paper, aiding future searches for orbital decay. With the help of published spectroscopic measurements and theoretical stellar models, we determine the physical properties of the system to high precision and present a detailed error budget for these calculations. The planet has a Roche lobe filling factor of 0.58, leading to a significant asphericity; we correct its measured mass and mean density for this phenomenon. A high-resolution Lucky Imaging observation shows no evidence for faint stars close enough to contaminate the point spread function of WASP-103. Our data were obtained in the Bessell $RI$ and the SDSS $griz$ passbands and yield a larger planet ...

  7. High precise control method for a new type of piezoelectric electro-hydraulic servo valve

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    A new type of piezoelectric electro-hydraulic servo valve system was proposed. And then multilayer piezoelectric actuator based on new piezoelectric ceramic material was used as the electricity-machine converter of the proposed piezoelectric electro-hydraulic servo valve. The proposed piezoelectric electro-hydraulic servo valve has ascendant performance compared with conventional ones. But the system is of high nonlinearity and uncertainty, it cannot achieve favorable control performance by conventional control method. To develop an efficient way to control piezoelectric electro-hydraulic servo valve system, a high-precise fuzzy control method with hysteresis nonlinear model in feedforward loop was proposed. The control method is separated into two parts: a feedforward loop with Preisach hysteresis nonlinear model and a feedback loop with high-precise fuzzy control. Experimental results show that the hysteresis loop and the maximum output hysteresis by the PID control method are 4.22%and 2.11 μm, respectively; the hysteresis loop and the maximum output hysteresis by the proposed control method respectively are 0.74% and 0.37 μm, respectively; the maximum tracking error by the PID control method for sine wave reference signal is about 5.02%, the maximum tracking error by the proposed control method for sine wave reference signal is about 0.85%.

  8. An Online Gravity Modeling Method Applied for High Precision Free-INS.

    Science.gov (United States)

    Wang, Jing; Yang, Gongliu; Li, Jing; Zhou, Xiao

    2016-09-23

    For real-time solution of inertial navigation system (INS), the high-degree spherical harmonic gravity model (SHM) is not applicable because of its time and space complexity, in which traditional normal gravity model (NGM) has been the dominant technique for gravity compensation. In this paper, a two-dimensional second-order polynomial model is derived from SHM according to the approximate linear characteristic of regional disturbing potential. Firstly, deflections of vertical (DOVs) on dense grids are calculated with SHM in an external computer. And then, the polynomial coefficients are obtained using these DOVs. To achieve global navigation, the coefficients and applicable region of polynomial model are both updated synchronously in above computer. Compared with high-degree SHM, the polynomial model takes less storage and computational time at the expense of minor precision. Meanwhile, the model is more accurate than NGM. Finally, numerical test and INS experiment show that the proposed method outperforms traditional gravity models applied for high precision free-INS.

  9. Frontend electronics for high-precision single photo-electron timing using FPGA-TDCs

    Energy Technology Data Exchange (ETDEWEB)

    Cardinali, M., E-mail: cardinal@kph.uni-mainz.de [Institut für Kernphysik, Johannes Gutenberg-University Mainz, Mainz (Germany); Helmholtz Institut Mainz, Mainz (Germany); Dzyhgadlo, R.; Gerhardt, A.; Götzen, K.; Hohler, R.; Kalicy, G.; Kumawat, H.; Lehmann, D.; Lewandowski, B.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Ugur, C.; Zühlsdorf, M. [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt (Germany); Dodokhov, V.Kh. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Britting, A. [Friedrich Alexander-University of Erlangen-Nuremberg, Erlangen (Germany); and others

    2014-12-01

    The next generation of high-luminosity experiments requires excellent particle identification detectors which calls for Imaging Cherenkov counters with fast electronics to cope with the expected hit rates. A Barrel DIRC will be used in the central region of the Target Spectrometer of the planned PANDA experiment at FAIR. A single photo-electron timing resolution of better than 100 ps is required by the Barrel DIRC to disentangle the complicated patterns created on the image plane. R and D studies have been performed to provide a design based on the TRB3 readout using FPGA-TDCs with a precision better than 20 ps RMS and custom frontend electronics with high-bandwidth pre-amplifiers and fast discriminators. The discriminators also provide time-over-threshold information thus enabling walk corrections to improve the timing resolution. Two types of frontend electronics cards optimised for reading out 64-channel PHOTONIS Planacon MCP-PMTs were tested: one based on the NINO ASIC and the other, called PADIWA, on FPGA discriminators. Promising results were obtained in a full characterisation using a fast laser setup and in a test experiment at MAMI, Mainz, with a small scale DIRC prototype. - Highlights: • Frontend electronics for Cherenkov detectors have been developed. • FPGA-TDCs have been used for high precision timing. • Time over threshold has been utilised for walk correction. • Single photo-electron timing resolution less than 100 ps has been achieved.

  10. Optimization design about gimbal structure of high-precision autonomous celestial navigation tracking mirror system

    Science.gov (United States)

    Huang, Wei; Yang, Xiao-xu; Han, Jun-feng; Wei, Yu; Zhang, Jing; Xie, Mei-lin; Yue, Peng

    2016-01-01

    High precision tracking platform of celestial navigation with control mirror servo structure form, to solve the disadvantages of big volume and rotational inertia, slow response speed, and so on. It improved the stability and tracking accuracy of platform. Due to optical sensor and mirror are installed on the middle-gimbal, stiffness and resonant frequency requirement for high. Based on the application of finite element modality analysis theory, doing Research on dynamic characteristics of the middle-gimbal, and ANSYS was used for the finite element dynamic emulator analysis. According to the result of the computer to find out the weak links of the structure, and Put forward improvement suggestions and reanalysis. The lowest resonant frequency of optimization middle-gimbal avoid the bandwidth of the platform servo mechanism, and much higher than the disturbance frequency of carrier aircraft, and reduces mechanical resonance of the framework. Reaching provides a theoretical basis for the whole machine structure optimization design of high-precision of autonomous Celestial navigation tracking mirror system.

  11. [High-precision 3D morphology measurement by digital gatling method based on structured light].

    Science.gov (United States)

    Luo, Gang-Yin; Tang, Yu-Guo; Qiao, Pei-Yu; Wang, Bi-Dou; Jia, Zan-Dong; Xu, Zhong

    2012-09-01

    In order to measure the microscopic 3D morphology of the objects with high-precision, a 3D texture measurement system of digital gatling based on structured light was designed, which can calculate the 3D height information with the analytic phase method. First, the authors collected sixteen equal step phase images by the four-step equal step method, and calculated their main value by dividing them into four groups. Then, the authors found the average as the final phase main value. The pretreatment on the fringe was done by the adaptive Wiener filter and wavelet multi-threshold method to eliminate the various effects of noise, projector distortion and CCD camera distortion. Besides, gradient-oriented phase unwrapping algorithm based on multifrequency was introduced to avoid phase discontinuity point in the course phase unwrapping, and it was proven to be effective and stable. Experiments showed that the system's 3D resolution was 2.75 microm, and the high degree accuracy was better than 0.5 microm, when the system was running with the fringe parameter p0 = 22.7 mm(-1). In addition, the system has many advantages such as fast measuring, simple operation and non-contact, which can meet the need of the high precision measurement requirements for the microscopic 3D morphology.

  12. High-precision gamma-ray spectroscopy for enhancing production and application of medical isotopes

    Science.gov (United States)

    McCutchan, E. A.; Sonzogni, A. A.; Smith, S. V.; Muench, L.; Nino, M.; Greene, J. P.; Carpenter, M. P.; Zhu, S.; Chillery, T.; Chowdhury, P.; Harding, R.; Lister, C. J.

    2015-10-01

    Nuclear medicine is a field which requires precise decay data for use in planning radionuclide production and in imaging and therapeutic applications. To address deficiencies in decay data, sources of medical isotopes were produced and purified at the Brookhaven Linear Isotope Producer (BLIP) then shipped to Argonne National Laboratory where high-precision, gamma-ray measurements were performed using Gammasphere. New decay schemes for a number of PET isotopes and the impact on dose calculations will be presented. To investigate the production of next-generation theranostic or radiotherapeutic isotopes, cross section measurements with high energy protons have also been explored at BLIP. The 100-200 MeV proton energy regime is relatively unexplored for isotope production, thus offering high discovery potential but at the same time a challenging analysis due to the large number of open channels at these energies. Results of cross sections deduced from Compton-suppressed, coincidence gamma-ray spectroscopy performed at Lowell will be presented, focusing on the production of platinum isotopes by irradiating natural platinum foils with 100 to 200 MeV protons. DOE Isotope Program is acknowledged for funding ST5001030. Work supported by the US DOE under Grant DE-FG02-94ER40848 and Contracts DE-AC02-98CH10946 and DE-AC02-06CH11357.

  13. Workshop on High-precision $\\alpha_s$ measurements from LHC to FCC-ee

    CERN Document Server

    S. Alekhin; d'Enterria, David; A. Banfi; S. Bethke; J. Blümlein; K.G. Chetyrkin; D. d’Enterria; G. Dissertori; X. Garcia i Tormo; A. H. Hoang; M. Klasen; T. Klijnsma; S. Kluth; J.-L. Kneur; B.A. Kniehl; D. W. Kolodrubetz; J. Kühn; P. Mackenzie; B. Malaescu; V. Mateu; L. Mihaila; S. Moch; K. Mönig; R. Pérez-Ramos; A. Pich; J. Pires; K. Rabbertz; G. P. Salam; F. Sannino; J. Soto i Riera; M. Srebre; I. W. Stewart

    2015-01-01

    This document provides a writeup of all contributions to the workshop on "High precision measurements of $\\alpha_s$: From LHC to FCC-ee" held at CERN, Oct. 12--13, 2015. The workshop explored in depth the latest developments on the determination of the QCD coupling $\\alpha_s$ from 15 methods where high precision measurements are (or will be) available. Those include low-energy observables: (i) lattice QCD, (ii) pion decay factor, (iii) quarkonia and (iv) $\\tau$ decays, (v) soft parton-to-hadron fragmentation functions, as well as high-energy observables: (vi) global fits of parton distribution functions, (vii) hard parton-to-hadron fragmentation functions, (viii) jets in $e^\\pm$p DIS and $\\gamma$-p photoproduction, (ix) photon structure function in $\\gamma$-$\\gamma$, (x) event shapes and (xi) jet cross sections in $e^+e^-$ collisions, (xii) W boson and (xiii) Z boson decays, and (xiv) jets and (xv) top-quark cross sections in proton-(anti)proton collisions. The current status of the theoretical and experiment...

  14. Spectrophotometric high-precision seawater pH determination for use in underway measuring systems

    Directory of Open Access Journals (Sweden)

    S. Aßmann

    2011-10-01

    Full Text Available Autonomous sensors are required for a comprehensive documentation of the changes in the marine carbon system and thus to differentiate between its natural variability and anthropogenic impacts. Spectrophotometric determination of pH – a key variable of the seawater carbon system – is particularly suited to achieve precise and drift-free measurements. However, available spectrophotometric instruments are not suitable for integration into automated measurement systems (e.g. FerryBox since they do not meet the major requirements of reliability, stability, robustness and moderate cost. Here we report on the development and testing of a~new indicator-based pH sensor that meets all of these requirements. This sensor can withstand the rough conditions during long-term deployments on ships of opportunity and is applicable to the open ocean as well as to coastal waters with a complex matrix and highly variable conditions. The sensor uses a high resolution CCD spectrometer as detector connected via optical fibers to a custom-made cuvette designed to reduce the impact of air bubbles. The sample temperature can be precisely adjusted (25 °C ± 0.006 °C using computer-controlled power supplies and Peltier elements thus avoiding the widely used water bath. The overall setup achieves a measurement frequency of 1 min−1 with a precision of ±0.0007 pH units, an average offset of +0.0005 pH units to a reference system, and an offset of +0.0081 pH units to a certified standard buffer. Application of this sensor allows monitoring of seawater pH in autonomous underway systems, providing a key variable for characterization and understanding of the marine carbon system.

  15. Spectrophotometric high-precision seawater pH determination for use in underway measuring systems

    Science.gov (United States)

    Aßmann, S.; Frank, C.; Körtzinger, A.

    2011-10-01

    Autonomous sensors are required for a comprehensive documentation of the changes in the marine carbon system and thus to differentiate between its natural variability and anthropogenic impacts. Spectrophotometric determination of pH - a key variable of the seawater carbon system - is particularly suited to achieve precise and drift-free measurements. However, available spectrophotometric instruments are not suitable for integration into automated measurement systems (e.g. FerryBox) since they do not meet the major requirements of reliability, stability, robustness and moderate cost. Here we report on the development and testing of a~new indicator-based pH sensor that meets all of these requirements. This sensor can withstand the rough conditions during long-term deployments on ships of opportunity and is applicable to the open ocean as well as to coastal waters with a complex matrix and highly variable conditions. The sensor uses a high resolution CCD spectrometer as detector connected via optical fibers to a custom-made cuvette designed to reduce the impact of air bubbles. The sample temperature can be precisely adjusted (25 °C ± 0.006 °C) using computer-controlled power supplies and Peltier elements thus avoiding the widely used water bath. The overall setup achieves a measurement frequency of 1 min-1 with a precision of ±0.0007 pH units, an average offset of +0.0005 pH units to a reference system, and an offset of +0.0081 pH units to a certified standard buffer. Application of this sensor allows monitoring of seawater pH in autonomous underway systems, providing a key variable for characterization and understanding of the marine carbon system.

  16. A low noise and high precision linear power supply with thermal foldback protection

    Science.gov (United States)

    Carniti, P.; Cassina, L.; Gotti, C.; Maino, M.; Pessina, G.

    2016-05-01

    A low noise and high precision linear power supply was designed for use in rare event search experiments with macrobolometers. The circuit accepts at the input a "noisy" dual supply voltage up to ±15 V and gives at the output precise, low noise, and stable voltages that can be set between ±3.75 V and ±12.5 V in eight 1.25 V steps. Particular care in circuit design, component selection, and proper filtering results in a noise spectral density of 50 nV / √{ Hz } at 1 Hz and 20 nV / √{ Hz } white when the output is set to ±5 V. This corresponds to 125 nV RMS (0.8 μV peak to peak) between 0.1 Hz and 10 Hz, and 240 nV RMS (1.6 μV peak to peak) between 0.1 Hz and 100 Hz. The power supply rejection ratio (PSRR) of the circuit is 100 dB at low frequency, and larger than 40 dB up to high frequency, thanks to a proper compensation design. Calibration allows to reach a precision in the absolute value of the output voltage of ±70 ppm, or ±350 μV at ±5 V, and to reduce thermal drifts below ±1 ppm/∘C in the expected operating range. The maximum peak output current is about 6 A from each output. An original foldback protection scheme was developed that dynamically limits the maximum output current to keep the temperature of the output transistors within their safe operating range. An add-on card based on an ARM Cortex-M3 microcontroller is devoted to the monitoring and control of all circuit functionalities and provides remote communication via CAN bus.

  17. Spectrophotometric high-precision seawater pH determination for use in underway measuring systems

    Directory of Open Access Journals (Sweden)

    S. Aßmann

    2011-06-01

    Full Text Available Autonomous sensors are required for a comprehensive documentation of the changes in the marine carbon system and thus to differentiate between its natural variability and anthropogenic impacts. Spectrophotometric determination of pH – a key variable of the seawater carbon system – is particularly suited to achieve precise and drift-free measurements. However, available spectrophotometric instruments are not suitable for integration into automated measurement systems (e.g. FerryBox since they do not meet the major requirements of reliability, stability, robustness and moderate cost. Here we report on the development and testing of a new indicator-based pH sensor that meets all of these requirements. This sensor can withstand the rough conditions during long-term deployments on ships of opportunities and is applicable on the open ocean as well as in coastal waters with complex background and highly variable conditions. The sensor uses a high resolution CCD spectrometer as detector connected via optical fibers to a custom-made cuvette designed to reduce the impact of air bubbles. The sample temperature can be precisely adjusted (25 °C ± 0.006 °C using computer-controlled power supplies and Peltier elements thus avoiding the widely used water bath. The overall setup achieves a measurement frequency of 1 min−1 with a precision of ± 0.0007 pH units and an average offset of +0.0018 pH units to a pH reference during shipboard operation. Application of this sensor allows monitoring of seawater pH in autonomous underway systems, providing a key variable for characterization and understanding the marine carbon system.

  18. The research of the high precision universal stable reconnaissance platform in near space

    Science.gov (United States)

    Yang, Hong-tao; Cao, Jian-zhong; Fan, Zhe-yuan; Chen, Wei-ning

    2011-08-01

    The appliance of military was recognized more and more ,It is important that pod can bear the weight of the availability payload achieve the observation to the earth in 20km-100km area and work in the all-weather. The stable platform can load high imaging spectrometer, the thermal infrared imager, the infrared radiometer, the millimeter waves radar, the laser weapon and so on,in order to realize reconnaissance and attacking integrative and warning the long-distant missile. The stabilization accuracy of platform is prior to 20μrad and burden heavy load to the best of one's abilities. It used high precision velocity and acceleration gyroscope to fulfill the stabilization of the platform. Light-weight design by using new composite material and optimizing design. It was adapt to the near space environment better by structure design and simulation analysis.Enhance its basic frequency and sure the rigid of the frame platform .In addition, the structure of platform apply the two-axis and four-frame and use the method of FEA to fulfill the optimum design in order to attain the object of light-weight.In consider to the precision of the platform I establish the math model and make use of the monte carlo method to appraise and analysis the error that affect the precision of the platform. After emulating by the software of the Matlab to verify the results. It is apply the method that link the platform and aerocraft by mounting the no angular displacement shock absorbers on the elevator mechanism. This kind of design insulate the angular vibration and minish the linear vibration to ensure the image quality.

  19. High Precision Momentum Calibration of the Magnetic Spectrometers at MAMI for Hypernuclear Binding Energy Determination

    CERN Document Server

    Margaryan, A; Achenbach, P; Ajvazyan, R; Elbakyan, H; Montgomery, R; Nakamura, S N; Pochodzalla, J; Schulz, F; Toyama, Y; Zhamkochyan, S

    2016-01-01

    We propose a new method for absolute momentum calibration of magnetic spectrometers used in nuclear physics, using the time-of-flight (TOF), differences of pairs of particles with different masses. In cases where the flight path is not known, a calibration can be determined by using the TOF differences of two pair combinations of three particles. A Cherenkov detector, read out by a radio frequency photomultiplier tube, is considered as the high-resolution and highly stable TOF detector. By means of Monte Carlo simulations it is demonstrated that the magnetic spectrometers at the MAMI electron-scattering facility can be calibrated absolutely with an accuracy $\\delta p/p\\leq 10^{-4}$, which will be crucial for high precision determination of hypernuclear masses.

  20. A novel approach for pulse width measurements with a high precision (8 ps RMS) TDC in an FPGA

    Science.gov (United States)

    Ugur, C.; Linev, S.; Michel, J.; Schweitzer, T.; Traxler, M.

    2016-01-01

    High precision time measurements are a crucial element in particle identification experiments, which likewise require pulse width information for Time-over-Threshold (ToT) measurements and charge measurements (correlated with pulse width). In almost all of the FPGA-based TDC applications, pulse width measurements are implemented using two of the TDC channels for leading and trailing edge time measurements individually. This method however, requires twice the number of resources. In this paper we present the latest precision improvements in the high precision TDC (8 ps RMS) developed before [1], as well as the novel way of measuring ToT using a single TDC channel, while still achieving high precision (as low as 11.7 ps RMS). The effect of voltage, generated by a DC-DC converter, over the precision is also discussed. Finally, the outcome of the temperature change over the pulse width measurement is shown and a correction method is suggested to limit the degradation.

  1. Shandong Hengyuan 200,000 tonnes of High-Precision Copper Product Project is Making Smooth Progress

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

    <正>Shandong Hengyuan Copper Co., Ltd is an emerging copper product processing enterprise in China, the company plans to invest 1 billion yuan to construct 200,000 t/a high precision copper product, which includes: 20,000 tones of precision copper tube and copper alloy tube, 10,000 tonnes of railway electrification copper

  2. An investigation of highly accurate and precise robotic hole measurements using non-contact devices

    Directory of Open Access Journals (Sweden)

    Usman Zahid

    2016-01-01

    Full Text Available Industrial robots arms are widely used in manufacturing industry because of their support for automation. However, in metrology, robots have had limited application due to their insufficient accuracy. Even using error compensation and calibration methods, robots are not effective for micrometre (μm level metrology. Non-contact measurement devices can potentially enable the use of robots for highly accurate metrology. However, the use of such devices on robots has not been investigated. The research work reported in this paper explores the use of different non-contact measurement devices on an industrial robot. The aim is to experimentally investigate the effects of robot movements on the accuracy and precision of measurements. The focus has been on assessing the ability to accurately measure various geometric and surface parameters of holes despite the inherent inaccuracies of industrial robot. This involves the measurement of diameter, roundness and surface roughness. The study also includes scanning of holes for measuring internal features such as start and end point of a taper. Two different non-contact measurement devices based on different technologies are investigated. Furthermore, effects of eccentricity, vibrations and thermal variations are also assessed. The research contributes towards the use of robots for highly accurate and precise robotic metrology.

  3. Velocity and abundance precisions for future high-resolution spectroscopic surveys: a study for 4MOST

    CERN Document Server

    Caffau, E; Sbordone, L; Sartoretti, P; Hansen, C J; Royer, F; Leclerc, N; Bonifacio, P; Christlieb, N; Ludwig, H G; Grebel, E K; de Jong, R S; Chiappini, C; Walcher, J; Mignot, S; Feltzing, S; Cohen, M; Minchev, I; Helmi, A; Piffl, T; Depagne, E; Schnurr, O

    2012-01-01

    In preparation for future, large-scale, multi-object, high-resolution spectroscopic surveys of the Galaxy, we present a series of tests of the precision in radial velocity and chemical abundances that any such project can achieve at a 4m class telescope. We briefly discuss a number of science cases that aim at studying the chemo-dynamical history of the major Galactic components (bulge, thin and thick disks, and halo) - either as a follow-up to the Gaia mission or on their own merits. Based on a large grid of synthetic spectra that cover the full range in stellar parameters of typical survey targets, we devise an optimal wavelength range and argue for a moderately high-resolution spectrograph. As a result, the kinematic precision is not limited by any of these factors, but will practically only suffer from systematic effects, easily reaching uncertainties <1 km/s. Under realistic survey conditions (namely, considering stars brighter than r=16 mag with reasonable exposure times) we prefer an ideal resolving...

  4. Aspects of ultra-high-precision diamond machining of RSA 443 optical aluminium

    Science.gov (United States)

    Mkoko, Z.; Abou-El-Hossein, K.

    2015-08-01

    Optical aluminium alloys such as 6061-T6 are traditionally used in ultra-high precision manufacturing for making optical mirrors for aerospace and other applications. However, the optics industry has recently witnessed the development of more advanced optical aluminium grades that are capable of addressing some of the issues encountered when turning with single-point natural monocrystalline diamond cutters. The advent of rapidly solidified aluminium (RSA) grades has generally opened up new possibilities for ultra-high precision manufacturing of optical components. In this study, experiments were conducted with single-point diamond cutters on rapidly solidified aluminium RSA 443 material. The objective of this study is to observe the effects of depth of cut and feed rate at a fixed rotational speed on the tool wear rate and resulting surface roughness of diamond turned specimens. This is done to gain further understanding of the rate of wear on the diamond cutters versus the surface texture generated on the RSA 443 material. The diamond machining experiments yielded machined surfaces which are less reflective but with consistent surface roughness values. Cutting tools were observed for wear through scanning microscopy; relatively low wear pattern was evident on the diamond tool edge. The highest tool wear were obtained at higher depth of cut and increased feed rate.

  5. FPGA-based High-precision Measurement Algorithm for the Ultrasonic Echo Time of Flight

    Institute of Scientific and Technical Information of China (English)

    Bo-xiong WANG; Jin ZHANG

    2010-01-01

    Based on the evaluation of advantages and disadvantages of high-precision digital time interval measuring algorithms, and combined with the principle of the typical time-difference ultrasonic flow measurement,the requirements far the measurement of echo time of flight put forward by the ultrasonic flow measurement are an-alyzed.A new high-precision time interval measurement algorithm is presented, which combines the pulse counting method with the phase delay interpolation. The pulse counting method is used to ensure a large dynamic measuring range, and a double-edge triggering counter is designed to improve the accuracy and reduce the counting quantiza-tion error.The phase delay interpolation is used to reduce the quanti-zation error of pulse counting for further improving the time measure-ment resolution.Test data show that the system for the measurement of the ultrasonic echo time of flight based on this algorithm and im-plemented on an Field Programmable Gate Array(FPGA) needs a rel-atively short time for measurement,and has a measurement error of less than 105 ps.

  6. Precision isotope shift measurements in Ca$^+$ using highly sensitive detection schemes

    CERN Document Server

    Gebert, Florian; Wolf, Fabian; Angstmann, Christopher N; Berengut, Julian C; Schmidt, Piet O

    2015-01-01

    We demonstrate an efficient high-precision optical spectroscopy technique for single trapped ions with non-closed transitions. In a double-shelving technique, the absorption of a single photon is first amplified to several phonons of a normal motional mode shared with a co-trapped cooling ion of a different species, before being further amplified to thousands of fluorescence photons emitted by the cooling ion using the standard electron shelving technique. We employ this extension of the photon recoil spectroscopy technique to perform the first high precision absolute frequency measurement of the $^{2}$D$_{3/2}$ $\\rightarrow$ $^{2}$P$_{1/2}$ transition in $^{40}$Ca$^{+}$, resulting in a transition frequency of $f=346\\, 000\\, 234\\, 867(96)$ kHz. Furthermore, we determine the isotope shift of this transition and the $^{2}$S$_{1/2}$ $\\rightarrow$ $^{2}$P$_{1/2}$ transition for $^{42}$Ca$^{+}$, $^{44}$Ca$^{+}$ and $^{48}$Ca$^{+}$ ions relative to $^{40}$Ca$^{+}$ with an accuracy below 100 kHz. Improved field and ...

  7. A High Precision Position Sensor Design and Its Signal Processing Algorithm for a Maglev Train

    Directory of Open Access Journals (Sweden)

    Wensen Chang

    2012-04-01

    Full Text Available High precision positioning technology for a kind of high speed maglev train with an electromagnetic suspension (EMS system is studied. At first, the basic structure and functions of the position sensor are introduced and some key techniques to enhance the positioning precision are designed. Then, in order to further improve the positioning signal quality and the fault-tolerant ability of the sensor, a new kind of discrete-time tracking differentiator (TD is proposed based on nonlinear optimal control theory. This new TD has good filtering and differentiating performances and a small calculation load. It is suitable for real-time signal processing. The stability, convergence property and frequency characteristics of the TD are studied and analyzed thoroughly. The delay constant of the TD is figured out and an effective time delay compensation algorithm is proposed. Based on the TD technology, a filtering process is introduced in to improve the positioning signal waveform when the sensor is under bad working conditions, and a two-sensor switching algorithm is designed to eliminate the positioning errors caused by the joint gaps of the long stator. The effectiveness and stability of the sensor and its signal processing algorithms are proved by the experiments on a test train during a long-term test run.

  8. A high precision position sensor design and its signal processing algorithm for a maglev train.

    Science.gov (United States)

    Xue, Song; Long, Zhiqiang; He, Ning; Chang, Wensen

    2012-01-01

    High precision positioning technology for a kind of high speed maglev train with an electromagnetic suspension (EMS) system is studied. At first, the basic structure and functions of the position sensor are introduced and some key techniques to enhance the positioning precision are designed. Then, in order to further improve the positioning signal quality and the fault-tolerant ability of the sensor, a new kind of discrete-time tracking differentiator (TD) is proposed based on nonlinear optimal control theory. This new TD has good filtering and differentiating performances and a small calculation load. It is suitable for real-time signal processing. The stability, convergence property and frequency characteristics of the TD are studied and analyzed thoroughly. The delay constant of the TD is figured out and an effective time delay compensation algorithm is proposed. Based on the TD technology, a filtering process is introduced in to improve the positioning signal waveform when the sensor is under bad working conditions, and a two-sensor switching algorithm is designed to eliminate the positioning errors caused by the joint gaps of the long stator. The effectiveness and stability of the sensor and its signal processing algorithms are proved by the experiments on a test train during a long-term test run.

  9. Towards high-precision mass measurements of neutron-rich fission products at TRIGA-SPEC

    Energy Technology Data Exchange (ETDEWEB)

    Nagy, Szilard [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany)

    2010-07-01

    TRIGA-TRAP, the only Penning trap mass spectrometer worldwide at a nuclear research reactor, is installed at TRIGA Mainz as part of the TRIGA-SPEC experiment. The scientific goal is to perform high-precision mass measurements on lanthanoids, actinoids and neutron-rich fission products produced by thermal neutron induced fission of a target inside the reactor. High-precision mass data are scarce in this region of the nuclear chart, and further experimental data are needed for nuclear structure studies of heavy elements, to test the predictive power of nuclear mass models, or as input to nucleosynthesis calculations of the astrophysical r-process. Ions of certain lanthanoids and most actinoids as well as carbon clusters for calibration purposes can be routinely produced by a newly developed non-resonant laser ablation ion source, allowing off-line mass measurements. Besides fundamental research, TRIGA-TRAP serves as a test bench for the development of efficient ion detection techniques, which will enable mass measurements ultimately on a single ion with a half-life of the order of one second. To this end, a unique combination of the commonly used time-of-flight technique and the non-destructive image current detection method is realized in an on-line mass spectrometer. The first mass measurement results are reported.

  10. High precision locations of long-period events at La Fossa Crater (Vulcano Island, Italy

    Directory of Open Access Journals (Sweden)

    Salvatore Rapisarda

    2009-06-01

    Full Text Available Since the last eruption in 1888-90, the volcanic activity on Vulcano Island (Aeolian Archipelago, Italy has been limited to fumarolic degassing. Fumaroles are mainly concentred at the active cone of La Fossa in the northern sector of the island and are periodically characterized by increases in temperature as well as in the amount of both CO2 and He. Seismic background activity at Vulcano is dominated by micro-seismicity originating at shallow depth (<1-1.5 km under La Fossa cone. This seismicity is related to geothermal system processes and comprises long period (LP events. LPs are generally considered as the resonance of a fluid-filled volume in response to a trigger. We analyzed LP events recorded during an anomalous degassing period (August-October 2006 applying a high precision technique to define the shape of the trigger source. Absolute and high precision locations suggest that LP events recorded at Vulcano during 2006 were produced by a shallow focal zone ca. 200 m long, 40 m wide and N30-40E oriented. Their occurrence is linked to magmatic fluid inputs that by modifying the hydrothermal system cause excitation of a fluid-filled cavity.

  11. Study of highly precise outdoor characterization technique for photovoltaic modules in terms of reproducibility

    Science.gov (United States)

    Fukabori, Akihiro; Takenouchi, Takakazu; Matsuda, Youji; Tsuno, Yuki; Hishikawa, Yoshihiro

    2015-08-01

    In this study, novel outdoor measurements were conducted for highly precise characterization of photovoltaic (PV) modules by measuring current-voltage (I-V) curves with fast sweep speeds and module’s temperature, and with a PV sensor for reference. Fast sweep speeds suppressed the irradiance variation. As a result, smooth I-V curves were obtained and the PV parameter deviation was suppressed. The module’s temperature was measured by attaching resistive temperature detector sensors on the module’s backsheet. The PV sensor was measured synchronously with the PV module. The PV parameters including Isc, Pmax, Voc, and FF were estimated after correcting the I-V curves using the IEC standards. The reproducibility of Isc, Pmax, Voc, and FF relative to the outdoor fits was evaluated as 0.43, 0.58, 0.24, and 0.23%, respectively. The results demonstrate that highly precise measurements are possible using a PV measurement system with the three above-mentioned features.

  12. High-precision predictions for the light CP-even Higgs boson mass of the MSSM

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, T.; Hollik, W. [Max-Planck-Institut fuer Physik, Muenchen (Germany); Heinemeyer, S. [Instituto de Fisica de Cantabria (CSIC-UC), Santander (Spain); Rzehak, H. [Freiburg Univ. (Germany). Physikalisches Inst.; Weiglein, G. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2014-03-15

    For the interpretation of the signal discovered in the Higgs searches at the LHC it will be crucial in particular to discriminate between the minimal Higgs sector realised in the Standard Model (SM) and its most commonly studied extension, the Minimal Supersymmetric SM (MSSM). The measured mass value, having already reached the level of a precision observable with an experimental accuracy of about 500 MeV, plays an important role in this context. In the MSSM the mass of the light CP-even Higgs boson, M{sub h}, can directly be predicted from the other parameters of the model. The accuracy of this prediction should at least match the one of the experimental result. The relatively high mass value of about 126 GeV has led to many investigations where the scalar top quarks are in the multi-TeV range. We improve the prediction for M{sub h} in the MSSM by combining the existing fixed-order result, comprising the full one-loop and leading and subleading two-loop corrections, with a resummation of the leading and subleading logarithmic contributions from the scalar top sector to all orders. In this way for the first time a high-precision prediction for the mass of the light CP-even Higgs boson in the MSSM is possible all the way up to the multi-TeV region of the relevant supersymmetric particles. The results are included in the code FeynHiggs.

  13. Detailed seismotectonic analysis of Sumatra subduction zone revealed by high precision earthquake location

    Science.gov (United States)

    Sagala, Ricardo Alfencius; Harjadi, P. J. Prih; Heryandoko, Nova; Sianipar, Dimas

    2017-07-01

    Sumatra was one of the most high seismicity regions in Indonesia. The subduction of Indo-Australian plate beneath Eurasian plate in western Sumatra contributes for many significant earthquakes that occur in this area. These earthquake events can be used to analyze the seismotectonic of Sumatra subduction zone and its system. In this study we use teleseismic double-difference method to obtain more high precision earthquake distribution in Sumatra subduction zone. We use a 3D nested regional-global velocity model. We use a combination of data from both of ISC (International Seismological Center) and BMKG (Agency for Meteorology Climatology and Geophysics, Indonesia). We successfully relocate about 6886 earthquakes that occur on period of 1981-2015. We consider that this new location is more precise than the regular bulletin. The relocation results show greatly reduced of RMS residual of travel time. Using this data, we can construct a new seismotectonic map of Sumatra. A well-built geometry of subduction slab, faults and volcano arc can be obtained from the new bulletin. It is also showed that at a depth of 140-170 km, there is many events occur as moderate-to-deep earthquakes, and we consider about the relation of the slab's events with volcanic arc and inland fault system. A reliable slab model is also built from regression equation using new relocated data. We also analyze the spatial-temporal of seismotectonic using b-value mapping that inspected in detail horizontally and vertically cross-section.

  14. Fully stabilized mid-infrared frequency comb for high-precision molecular spectroscopy.

    Science.gov (United States)

    Vainio, Markku; Karhu, Juho

    2017-02-20

    A fully stabilized mid-infrared optical frequency comb spanning from 2.9 to 3.4 µm is described in this article. The comb is based on half-harmonic generation in a femtosecond optical parametric oscillator, which transfers the high phase coherence of a fully stabilized near-infrared Er-doped fiber laser comb to the mid-infrared region. The method is simple, as no phase-locked loops or reference lasers are needed. Precise locking of optical frequencies of the mid-infrared comb to the pump comb is experimentally verified at sub-20 mHz level, which corresponds to a fractional statistical uncertainty of 2 × 10-16 at the center frequency of the mid-infrared comb. The fully stabilized mid-infrared comb is an ideal tool for high-precision molecular spectroscopy, as well as for optical frequency metrology in the mid-infrared region, which is difficult to access with other stabilized frequency comb techniques.

  15. A design of High-precision High-Voltage Fiber-Optic Analog Signal Isolation Converter

    Institute of Scientific and Technical Information of China (English)

    李建伟; 许留伟; 刘小宁; 杨雷

    2002-01-01

    This paper introduces a design of high-prectison high-voltage fiber-optic analog sig-nal isoaltion converter based on the technology of Voltage-to-Fequency (V/F)and Frequency -to Voltage(F/V) conversion It describes the principle ,system configuration and hardware design

  16. High-precision temporal constraints on intrusive magmatism of the Siberian Traps

    Science.gov (United States)

    Burgess, Seth; Bowring, Sam; Pavlov, Volodia E.; Veselovsky, Roman V.

    2014-05-01

    The broad temporal coincidence between large igneous province magmatism and some of the most severe biotic/environmental crises in Earth history has led many to infer a causal connection between the two. Notable examples include the end-Permian mass extinction and eruption/emplacement of the Siberian Traps large igneous province (LIP) and the end-Triassic mass extinction and the Central Atlantic Magmatic Province. In models proposing a causal connection between LIP magmatism and the environmental changes that lead to mass extinction, gases and particulates injected into the atmosphere are thought to cause abrupt changes in climate and ocean chemistry sufficient to drive mass extinction of marine and terrestrial biota. Magmatism has been proposed to cause voluminous volatile release via contact metamorphism of the sedimentary rocks. In the case of the Siberian Traps LIP, the compositions of sedimentary rocks (carbonates, evaporates, organic-rich shales) that host sills and dikes are ideal for greenhouse gas generation. When coupled with the enormous volume of Siberian LIP intrusive rocks, there is the potential for volatile generation on a scale necessary to drive environmental changes and mass extinction. This model must be tested by comparing the timing of intrusive magmatism with that of the mass extinction. Coupled high-precision geochronology and astrochronology have constrained the timing of biotic crisis and associated environmental perturbations from the deca-millennial to sub-millennial timescale, suggesting that the biotic crisis was abrupt, occurring over < 100 ka. Published geochronology on sills and dikes from the LIP are sparse and lack the necessary precision to resolve the relative timing of the two events outside of age uncertainty. We present new high-precision U-Pb zircon geochronology on seventeen gabbroic sills from throughout the magmatic province. This includes samples from the mineralized and differentiated intrusions in the Noril'sk region

  17. Efficacy of high intensity exercise on disease activity and cardiovascular risk in active axial spondyloarthritis: a randomized controlled pilot study.

    Directory of Open Access Journals (Sweden)

    Silje Halvorsen Sveaas

    Full Text Available BACKGROUND: Physical therapy is recommended for the management of axial spondyloarthritis (axSpA and flexibility exercises have traditionally been the main focus. Cardiovascular (CV diseases are considered as a major health concern in axSpA and there is strong evidence that endurance and strength exercise protects against CV diseases. Therefore, the aim of this study was to investigate the efficacy of high intensity endurance and strength exercise on disease activity and CV health in patients with active axSpA. METHODS: In a single blinded randomized controlled pilot study the exercise group (EG performed 12 weeks of endurance and strength exercise while the control group (CG received treatment as usual. The primary outcome was the Ankylosing Spondylitis (AS Disease Activity Score (ASDAS. Secondary outcomes included patient reported disease activity (Bath AS Disease Activity Index [BASDAI], physical function (Bath AS Functional Index [BASFI], and CV risk factors measured by arterial stiffness (Augmentation Index [Alx] and Pulse Wave Velocity [PWV], cardiorespiratory fitness (VO2 peak and body composition. ANCOVA on the post intervention values with baseline values as covariates was used to assess group differences, and Mann Whitney U-test was used for outcomes with skewed residuals. RESULTS: Twenty-eight patients were included and 24 (EG, n = 10, CG, n = 14 completed the study. A mean treatment effect of -0.7 (95%CI: -1.4, 0.1 was seen in ASDAS score. Treatment effects were also observed in secondary outcomes (mean group difference [95%CI]: BASDAI: -2.0 (-3.6, -0.4, BASFI: -1.4 (-2.6, -0.3, arterial stiffness (estimated median group differences [95% CI]: AIx (%: -5.3 (-11.0, -0.5, and for PVW (m/s: -0.3 (-0.7, 0.0, VO2 peak (ml/kg/min (mean group difference [95%CI]: 3.7 (2.1, 5.2 and trunk fat (%: -1.8 (-3.0, -0.6. No adverse events occurred. CONCLUSION: High intensity exercise improved disease activity and reduced CV risk factors in

  18. Efficacy of high intensity exercise on disease activity and cardiovascular risk in active axial spondyloarthritis: a randomized controlled pilot study.

    Science.gov (United States)

    Sveaas, Silje Halvorsen; Berg, Inger Jorid; Provan, Sella Aarrestad; Semb, Anne Grete; Hagen, Kåre Birger; Vøllestad, Nina; Fongen, Camilla; Olsen, Inge C; Michelsen, Annika; Ueland, Thor; Aukrust, Pål; Kvien, Tore K; Dagfinrud, Hanne

    2014-01-01

    Physical therapy is recommended for the management of axial spondyloarthritis (axSpA) and flexibility exercises have traditionally been the main focus. Cardiovascular (CV) diseases are considered as a major health concern in axSpA and there is strong evidence that endurance and strength exercise protects against CV diseases. Therefore, the aim of this study was to investigate the efficacy of high intensity endurance and strength exercise on disease activity and CV health in patients with active axSpA. In a single blinded randomized controlled pilot study the exercise group (EG) performed 12 weeks of endurance and strength exercise while the control group (CG) received treatment as usual. The primary outcome was the Ankylosing Spondylitis (AS) Disease Activity Score (ASDAS). Secondary outcomes included patient reported disease activity (Bath AS Disease Activity Index [BASDAI]), physical function (Bath AS Functional Index [BASFI]), and CV risk factors measured by arterial stiffness (Augmentation Index [Alx]) and Pulse Wave Velocity [PWV]), cardiorespiratory fitness (VO2 peak) and body composition. ANCOVA on the post intervention values with baseline values as covariates was used to assess group differences, and Mann Whitney U-test was used for outcomes with skewed residuals. Twenty-eight patients were included and 24 (EG, n = 10, CG, n = 14) completed the study. A mean treatment effect of -0.7 (95%CI: -1.4, 0.1) was seen in ASDAS score. Treatment effects were also observed in secondary outcomes (mean group difference [95%CI]): BASDAI: -2.0 (-3.6, -0.4), BASFI: -1.4 (-2.6, -0.3), arterial stiffness (estimated median group differences [95% CI]): AIx (%): -5.3 (-11.0, -0.5), and for PVW (m/s): -0.3 (-0.7, 0.0), VO2 peak (ml/kg/min) (mean group difference [95%CI]: 3.7 (2.1, 5.2) and trunk fat (%): -1.8 (-3.0, -0.6). No adverse events occurred. High intensity exercise improved disease activity and reduced CV risk factors in patients with active axSpA. These

  19. Development of a High Precision and Stability Ambient N2O and CO Analyzer

    Science.gov (United States)

    Zhou, Jingang; Hoffnagle, John; Tan, Sze; Dong, Feng; Fleck, Derek; Yiu, John; Huang, Kuan; Leggett, Graham; He, Yonggang

    2016-04-01

    With a global warming potential of nearly 300, N2O is a critically important greenhouse gas, contributing about 5 % of the US total GHG emissions. Agriculture soil management practices are the dominant source of anthropogenic N2O emissions, contributing nearly 75 % of US N2O emissions. In urban areas, vehicle tailpipe emissions and waste water treatment plants are significant sources of N2O. We report here a new mid-infrared laser-based cavity ring-down spectrometer (Picarro G5310) that was recently developed to simultaneously measure sub-ppb ambient concentrations of two key greenhouse gas species, N2O and CO, while measuring H2O as well. It combines a quantum cascade laser with a proprietary 3-mirror optical cavity. The ambient N2O and CO measurement precisions are 0.1ppb (10sec), 0.014ppb (600sec), and 0.006ppb (3000sec); and the measurements could even be averaged down over 3 hours, giving measurement precisions of 0.003ppb. The measurable N2O and CO ranges have been tested up to 2.5ppm. With the high precision and unparalleled stability, G5310 is believed a promising tool for long-term monitoring in atmospheric sciences. The new optical analyzer was set up to monitor N2O and CO (G5310), along with CO2 and CH4(G4301), in ambient air obtained from a 10 meter tower in Santa Clara, California. Evidence of contributions from traffic and a nearby sewage treatment facility were expected in the measurement data.

  20. A high-precision protocol for identification of preschool children at risk for persisting obesity.

    Directory of Open Access Journals (Sweden)

    Toomas Timpka

    Full Text Available BACKGROUND: Recent studies suggest that adolescent adiposity is established already in preadolescence. Earlier studies have confirmed a strong tracking of obesity from adolescence to adulthood. Our aim was to examine the diagnostic accuracy of a population-derived protocol for identification of preschool children at risk for obesity in preadolescence. METHODOLOGY/PRINCIPAL FINDINGS: We analysed data obtained for child health surveillance up to age 5 from 5778 children born in a Swedish county in 1991. The basic data set included age, sex, and weight and height measurements from the regular checkups between ages 1.5 and 5. Data not routinely collected in the child health centre setting were disregarded. The children were at age 10 randomly assigned to protocol derivation and validation cohorts and assessed for obesity according to IOTF criteria. The accuracy of predicting obesity in the validation cohort was measured using decision precision, specificity, and sensitivity. The decision protocol selected 1.4% of preschool children as being at obesity risk. The precision of the protocol at age 10 was 82% for girls and 80% for boys, and the specificity was 100% for both boys and girls. The sensitivity was higher for girls (41% than for boys (21%. The relative risk for obesity at age 10 estimated by the odds ratio for individuals selected by the protocol compared to non-selected peers was 212.6 (95% confidence interval 56.6 to 798.4 for girls and 120.3 (95% CI 24.5 to 589.9 for boys. CONCLUSION/SIGNIFICANCE: A simple and inexpensive decision protocol based on BMI values proved to have high precision and specificity for identification of preschool children at risk for obesity persisting into adolescence, while the sensitivity was low especially for boys. Implementation and further evaluations of the protocol in child health centre settings are warranted.

  1. Highly precise and developmentally programmed genome assembly in Paramecium requires ligase IV-dependent end joining.

    Directory of Open Access Journals (Sweden)

    Aurélie Kapusta

    2011-04-01

    Full Text Available During the sexual cycle of the ciliate Paramecium, assembly of the somatic genome includes the precise excision of tens of thousands of short, non-coding germline sequences (Internal Eliminated Sequences or IESs, each one flanked by two TA dinucleotides. It has been reported previously that these genome rearrangements are initiated by the introduction of developmentally programmed DNA double-strand breaks (DSBs, which depend on the domesticated transposase PiggyMac. These DSBs all exhibit a characteristic geometry, with 4-base 5' overhangs centered on the conserved TA, and may readily align and undergo ligation with minimal processing. However, the molecular steps and actors involved in the final and precise assembly of somatic genes have remained unknown. We demonstrate here that Ligase IV and Xrcc4p, core components of the non-homologous end-joining pathway (NHEJ, are required both for the repair of IES excision sites and for the circularization of excised IESs. The transcription of LIG4 and XRCC4 is induced early during the sexual cycle and a Lig4p-GFP fusion protein accumulates in the developing somatic nucleus by the time IES excision takes place. RNAi-mediated silencing of either gene results in the persistence of free broken DNA ends, apparently protected against extensive resection. At the nucleotide level, controlled removal of the 5'-terminal nucleotide occurs normally in LIG4-silenced cells, while nucleotide addition to the 3' ends of the breaks is blocked, together with the final joining step, indicative of a coupling between NHEJ polymerase and ligase activities. Taken together, our data indicate that IES excision is a "cut-and-close" mechanism, which involves the introduction of initiating double-strand cleavages at both ends of each IES, followed by DSB repair via highly precise end joining. This work broadens our current view on how the cellular NHEJ pathway has cooperated with domesticated transposases for the emergence of new

  2. Depth Impact Control of an Electromagnetic Actuator for High Precision Engraving

    Directory of Open Access Journals (Sweden)

    E. Castillo–Castañeda

    2008-10-01

    Full Text Available This document presents both the mechanical elements and the motion control of a novel three–axis metal engraving machine. The aim of this work is to improve the conventional high resolution engraving techniques that commonly use expensive piezoelectric actuators with reduced impact depth. Also, it is presented the depth impact control in open loop for an electromagnetic actuator (solenoid. A conical tool is fixed on the mobile part of the solenoid that moves toward the work piece when the solenoid is energized. This novel machine performs micro–impacts of controlled depth on metallic flat surfaces and it can be also applied to high precision machining processes. The machine was experimentally tested on steel work pieces using scanned pictures.

  3. High precision mapping of kidney stones using μ-IR spectroscopy to determine urinary lithogenesis.

    Science.gov (United States)

    Blanco, Francisco; Ortiz-Alías, Pilar; López-Mesas, Montserrat; Valiente, Manuel

    2015-06-01

    Evolution of urinary lithiasis is determined by the metabolism and life-style of the related patient. The appropriate classification of the stone is mandatory for the identification of the lithogenic process. In this study, cros-sections from a single stone of each of the most frequent urolithiasis types (calcium oxalate mono and dihydrate and carbonate apatite) have been selected and imaged using IR microspectroscopy. Moreover, the use of high definition sFTIR (synchrotron source) has revealed hidden information to the conventional FTIR. This work has demonstrated that minor components become key factors on the description of the stages of stone formation. Intensity map for COM (1630 cm(-1) peak). The high spatial definition achieved is key for the precise description of the kidney stone history.

  4. A high-precision cryogenically-cooled crystal monochromator for the APS diagnostics beamline

    Energy Technology Data Exchange (ETDEWEB)

    Rotela, E.; Yang, B.; Sharma, s.; Barcikowski, A.

    2000-07-24

    A high-precision cryogenically-cooled crystal monochromator has been developed for the APS diagnostics beamline. The design permits simultaneous measurements of the particle beam size and divergence. It provides for a large rotation angle, {minus}15{degree} to 180{degree}, with a resolution of 0.0005{degree}. The roll angle of the crystal can be adjusted by up to {+-}3{degree} with a resolution of 0.0001{degree}. A vertical translational stage, with a stroke of {+-}25 mm and resolution of 8 {micro}m, is provided to enable using different parts of the same crystal or to retract the crystal from the beam path. The modular design will allow optimization of cooling schemes to minimize thermal distortions of the crystal under high heat loads.

  5. High accuracy and precision micro injection moulding of thermoplastic elastomers micro ring production

    DEFF Research Database (Denmark)

    Calaon, Matteo; Tosello, Guido; Elsborg, René

    2016-01-01

    of using tool geometries as reference calibrated artefacts to establish effective process technology development and control. The results allow identifying the correct process windows for optimal part quality reducing product dimensional variation in the micrometer dimensional range. The proposed......The mass-replication nature of the process calls for fast monitoring of process parameters and product geometrical characteristics. In this direction, the present study addresses the possibility to develop a micro manufacturing platform for micro assembly injection moulding with real-time process/product...... monitoring and metrology. The study represent a new concept yet to be developed with great potential for high precision mass-manufacturing of highly functional 3D multi-material (i.e. including metal/soft polymer) micro components. The activities related to HINMICO project objectives proves the importance...

  6. Note: High precision angle generator using multiple ultrasonic motors and a self-calibratable encoder

    Science.gov (United States)

    Kim, Jong-Ahn; Kim, Jae Wan; Kang, Chu-Shik; Jin, Jonghan; Bong Eom, Tae

    2011-11-01

    We present an angle generator with high resolution and accuracy, which uses multiple ultrasonic motors and a self-calibratable encoder. A cylindrical air bearing guides a rotational motion, and the ultrasonic motors achieve high resolution over the full circle range with a simple configuration. The self-calibratable encoder can compensate the scale error of a divided circle (signal period: 20″) effectively by applying the equal-division-averaged method. The angle generator configures a position feedback control loop using the readout of the encoder. By combining the ac and dc operation mode, the angle generator produced stepwise angular motion with 0.005″ resolution. We also evaluated the performance of the angle generator using a precision angle encoder and an autocollimator. The expanded uncertainty (k = 2) in the angle generation was estimated less than 0.03″, which included the calibrated scale error and the nonlinearity error.

  7. Flow-Based Systems for Rapid and High-Precision Enzyme Kinetics Studies

    Directory of Open Access Journals (Sweden)

    Supaporn Kradtap Hartwell

    2012-01-01

    Full Text Available Enzyme kinetics studies normally focus on the initial rate of enzymatic reaction. However, the manual operation of steps of the conventional enzyme kinetics method has some drawbacks. Errors can result from the imprecise time control and time necessary for manual changing the reaction cuvettes into and out of the detector. By using the automatic flow-based analytical systems, enzyme kinetics studies can be carried out at real-time initial rate avoiding the potential errors inherent in manual operation. Flow-based systems have been developed to provide rapid, low-volume, and high-precision analyses that effectively replace the many tedious and high volume requirements of conventional wet chemistry analyses. This article presents various arrangements of flow-based techniques and their potential use in future enzyme kinetics applications.

  8. High precision Cross-correlated imaging in Few-mode fibers

    DEFF Research Database (Denmark)

    Muliar, Olena; Usuga Castaneda, Mario A.; Kristensen, Torben

    2017-01-01

    ) in a few-mode fiber (FMF) are used as multiple spatial communication channels, comes in this context as a viable approach to enable the optimization of high-capacity links. From this perspective, it becomes highly necessary to possess a diagnostic tool for the precise modal characterization of FMFs. Among...... us to distinguishing differential time delays between HOMs in the picosecond timescale. Broad wavelength scanning in combination with spectral shaping, allows us to estimate the modal behavior of FMF without prior knowledge of the fiber parameters. We performed our demonstration at wavelengths from...... 850nm to 1100nm which can be easily extended to other wavelengths of interest just by replacing components with the appropriate coating. The method presented here aims to serve as flexible diagnostic tool that can be implemented in MDM systems for judicious evaluation of modal dispersion in FMFs...

  9. High-precision soft x-ray polarimeter at Diamond Light Source.

    Science.gov (United States)

    Wang, H; Dhesi, S S; Maccherozzi, F; Cavill, S; Shepherd, E; Yuan, F; Deshmukh, R; Scott, S; van der Laan, G; Sawhney, K J S

    2011-12-01

    The development and performance of a high-precision polarimeter for the polarization analysis in the soft x-ray region is presented. This versatile, high-vacuum compatible instrument is supported on a hexapod to simplify the alignment with a resolution less than 5 μrad, and can be moved with its own independent control system easily between different beamlines and synchrotron facilities. The polarimeter can also be used for the characterization of reflection and transmission properties of optical elements. A W/B(4)C multilayer phase retarder was used to characterize the polarization state up to 1200 eV. A fast and accurate alignment procedure was developed, and complete polarization analysis of the APPLE II undulator at 712 eV has been performed.

  10. High-precision optomechanical lens system for space applications assembled by a local soldering technique

    Science.gov (United States)

    Pleguezuelo, Pol Ribes; Koechlin, Charlie; Hornaff, Marcel; Kamm, Andreas; Beckert, Erik; Fiault, Guillaume; Eberhardt, Ramona; Tünnermann, Andreas

    2016-06-01

    Soldering using metallic solder alloys is an alternative to adhesive bonding. Laser-based soldering processes are especially well suited for the joining of optical components made of fragile and brittle materials such as glass, ceramics, and optical crystals. This is due to a localized and minimized input of thermal energy. Solderjet bumping technology has been used to assemble a lens mount breadboard using specifications and requirements found for the optical beam expander for the European Space Agency EarthCare Mission. The silica lens and a titanium barrel have been designed and assembled with this technology in order to withstand the stringent mission demands of handling high mechanical and thermal loads without losing the optical performance. Finally, a high-precision optomechanical lens mount has been assembled with minimal localized stress (<1 MPa) showing outstanding performance in terms of wave-front error and beam depolarization ratio before and after environmental tests.

  11. High-precision soft x-ray polarimeter at Diamond Light Source

    Science.gov (United States)

    Wang, H.; Dhesi, S. S.; Maccherozzi, F.; Cavill, S.; Shepherd, E.; Yuan, F.; Deshmukh, R.; Scott, S.; van der Laan, G.; Sawhney, K. J. S.

    2011-12-01

    The development and performance of a high-precision polarimeter for the polarization analysis in the soft x-ray region is presented. This versatile, high-vacuum compatible instrument is supported on a hexapod to simplify the alignment with a resolution less than 5 μrad, and can be moved with its own independent control system easily between different beamlines and synchrotron facilities. The polarimeter can also be used for the characterization of reflection and transmission properties of optical elements. A W/B4C multilayer phase retarder was used to characterize the polarization state up to 1200 eV. A fast and accurate alignment procedure was developed, and complete polarization analysis of the APPLE II undulator at 712 eV has been performed.

  12. High-precision photometry by telescope defocussing. VI. WASP-24, WASP-25 and WASP-26

    CERN Document Server

    Southworth, John; Burgdorf, M; Novati, S Calchi; Dominik, M; Galianni, P; Gerner, T; Giannini, E; Gu, S -H; Hundertmark, M; Jorgensen, U G; Juncher, D; Kerins, E; Mancini, L; Rabus, M; Ricci, D; Schaefer, S; Skottfelt, J; Tregloan-Reed, J; Wang, X -B; Wertz, O; Alsubai, K A; Andersen, J M; Bozza, V; Bramich, D M; Browne, P; Ciceri, S; D'Ago, G; Damerdji, Y; Diehl, C; Dodds, P; Elyiv, A; Fang, X -S; Finet, F; Jaimes, R Figuera; Hardis, S; Harpsoe, K; Jessen-Hansen, J; Kains, N; Kjeldsen, H; Korhonen, H; Liebig, C; Lund, M N; Lundkvist, M; Mathiasen, M; Penny, M T; Popovas, A; Proft, S; Rahvar, S; Sahu, K; Scarpetta, G; Schmidt, R W; Schoenebeck, F; Snodgrass, C; Street, R A; Surdej, J; Tsapras, Y; Vilela, C

    2014-01-01

    We present time-series photometric observations of thirteen transits in the planetary systems WASP-24, WASP-25 and WASP-26. All three systems have orbital obliquity measurements, WASP-24 and WASP-26 have been observed with Spitzer, and WASP-25 was previously comparatively neglected. Our light curves were obtained using the telescope-defocussing method and have scatters of 0.5 to 1.2 mmag relative to their best-fitting geometric models. We used these data to measure the physical properties and orbital ephemerides of the systems to high precision, finding that our improved measurements are in good agreement with previous studies. High-resolution Lucky Imaging observations of all three targets show no evidence for faint stars close enough to contaminate our photometry. We confirm the eclipsing nature of the star closest to WASP-24 and present the detection of a detached eclipsing binary within 4.25 arcmin of WASP-26.

  13. High precision measurement of formaldehyde in air with differential optical absorption spectroscopy

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The formaldehyde (HCHO) measurement is described by differential optical absorption spectroscopy (DOAS) technique and the data processing method is discussed in detail, including the selection of retrieval wavelength band, the removing of interfering structures, the steps of data processing and the spectrum dealing with nonlinear method. The HCHO concentration retrieved in different wavelength bands were compared, including relative error, repeatability and detection limit. As a result, the band from 314 to 332 nm was most suitable for the retrieval of HCHO. With these methods, high measurement precision of 1.9% was obtained and the detection limit of HCHO is less than 1.5 ppb. In addition, high linear relativity 0.9999 is achieved by measuring five different concentrations of HCHO with this system.

  14. High Precision Stokes Polarimetry for Scattering Light using Wide Dynamic Range Intensity Detector

    Directory of Open Access Journals (Sweden)

    Shibata Shuhei

    2015-01-01

    Full Text Available This paper proposes a Stokes polarimetry for scattering light from a sample surface. To achieve a high accuracy measurement two approaches of an intensity detector and analysis algorism of a Stokes parameter were proposed. The dynamic range of this detector can achieve up to 1010 by combination of change of neutral-density (ND filters having different density and photon counting units. Stokes parameters can be measured by dual rotating of a retarder and an analyzer. The algorism of dual rotating polarimeter can be calibrated small linear diattenuation and linear retardance error of the retarder. This system can measured Stokes parameters from −20° to 70° of its scattering angle. It is possible to measure Stokes parameters of scattering of dust and scratch of optical device with high precision. This paper shows accuracy of this system, checking the polarization change of scattering angle and influence of beam size.

  15. New high precision data on the differential cross sections of the pion-proton elastic scattering

    Directory of Open Access Journals (Sweden)

    Alekseev I. G.

    2014-01-01

    Full Text Available The EPECUR collaboration presents new high precision data on the pion-proton elastic scattering in the second resonance region. The experiment EPECUR is placed on the universal beam channel of the accelerator ITEP. The setup features 0.1% beam pion momentum tagging system, 25 cm long liquid hydrogen target, placed in mylar container and beryllium outer shell, low material wire drift chambers and high performance DAQ. More than 3 billions of triggers have been collected. The data cover pion beam momentum range 0.8 - 1.3 GeV/c and 40-120 degrees center-of-mass scattering angle range for both positive and negative pions. The measured differential cross section has 2% statistical accuracy in 2 degrees angle and 5 MeV/c momentum intervals.

  16. High-precision atom localization via controllable spontaneous emission in a cycle-configuration atomic system.

    Science.gov (United States)

    Ding, Chunling; Li, Jiahua; Yu, Rong; Hao, Xiangying; Wu, Ying

    2012-03-26

    A scheme for realizing two-dimensional (2D) atom localization is proposed based on controllable spontaneous emission in a coherently driven cycle-configuration atomic system. As the spatial-position-dependent atom-field interaction, the frequency of the spontaneously emitted photon carries the information about the position of the atom. Therefore, by detecting the emitted photon one could obtain the position information available, and then we demonstrate high-precision and high-resolution 2D atom localization induced by the quantum interference between the multiple spontaneous decay channels. Moreover, we can achieve 100% probability of finding the atom at an expected position by choosing appropriate system parameters under certain conditions.

  17. A sub-1 V high-precision CMOS bandgap voltage reference

    Institute of Scientific and Technical Information of China (English)

    廖峻; 赵毅强; 耿俊峰

    2012-01-01

    A third-order,sub-1 V bandgap voltage reference design for low-power supply,high-precision applications is presented.This design uses a current-mode compensation technique and temperature-dependent resistor ratio to obtain high-order curvature compensation.The circuit was designed and fabricated by SMIC 0.18μm CMOS technology.It produces an output reference of 713.6 mV.The temperature coefficient is 3.235 pprn/℃ in the temperature range of-40 to 120 ℃,with a line regulation of 0.199 mV/V when the supply voltage varies from 0.95 to 3 V.The average current consumption of the whole circuit is 49 μA at the supply voltage of 1 V.

  18. HIGH-PRECISION DETERMINATION OF THE ANGULAR POSITION FOR POINT LIGHT SOURCE WITH CCD-ARRAYS

    Directory of Open Access Journals (Sweden)

    Y. G. Lebedko

    2015-05-01

    Full Text Available Subject of study. A method of angular position measuring for point light source in the system with CCD arrays is proposed by converting of angle – time – code in low light conditions and at high signal / noise ratio. Assessment of the method potential accuracy is given. It is determined by instrumental irremovable random errors of measurement in terms of optimal processing of incoming information with a single reading it with CCD – arrays. Method. This work introduces an optoelectronic system circuit with CCD arrays with stretched sensing elements and a point of reference for angular position measuring. In this case the arrays have images projections of both the reference point source and the target point source, which angular position is measured with high precision. From the CCD array output the signals arrive at an optimal (or apt linear filter, and then to the signal peak position detection circuit. The scheme provides minimum error due to the influence of noise. Pulse edges, corresponding to the signals maximum, make a time interval filled with high-frequency counting pulses. The number of pulses in this interval will correspond to the measured angular position of the target point source. Main results. Analysis of random errors has been carried out in terms of statistical decision theory. Analysis takes into account the spectral function of the signals defined by transfer functions of the optical system and a CCD array as an image analyzer. Research of measurement accuracy is carried out depending on the clock frequency of reading information from CCD arrays for different values of signal-to-noise ratio. It has been shown that even with a single readout with CCD array by the proposed opto-electronic circuit measuring error does not exceed 0.01 of the sensing element size. Practical significance. The results are usable in high-precision measuring opto-electronic systems of star sensors for determining the angular position of the low

  19. GPS inland water buoys for precise and high temporal resolution water level and movement monitoring

    Science.gov (United States)

    Apel, Heiko; Nghia Hung, Nguyen; Thoss, Heiko; Güntner, Andreas

    2010-05-01

    Monitoring of river and lake stages is one of the basic issues in understanding catchment hydrology and hydraulic systems. There are numerous techniques available for this, but in case of large water bodies technical as well as financial problems may restrict the use of traditional techniques. Therefore we explored the potential of GPS based altimetry for stage monitoring by developing small and easy to handle buoys with mounted high precision GPS devices. The advantages of the buoys are the freedom of positioning over the whole water body and their quick and easy deployment. The developed devices were tested in the Mekong Delta, Vietnam in two different locations: On the Mekong river where high currents over the flood season occur and in a small lake with hydraulic connections to a major channel with hardly any currents present. The collected GPS data were processed differentially and tested against standard pressure gauge data. The recorded stages proved to be of high quality and a valuable resource for flood monitoring and modeling. In addition to the stage data, the high-precision GPS positioning data could also be used for monitoring the movement of the buoys, from which alternating currents caused by ocean tides and flood waves could be detected, thus providing an additional information on the hydraulic system. We conclude that the developed buoys add well to the existing hydrological monitoring pool and are a goof option for the monitoring in large water bodies where a) traditional methods are technically difficult to deploy or are too costly, and b) where additional information about flow direction is needed.

  20. New Progress in High-Precision and High-Resolution Seismic Exploration Technique in Coal Industry of China

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    In the past twenty years, the proportion of coal in primary-energy consumption in China is generally between 71.3% and 76.5%. The output of coal was 1.374 billion tons in 1996, and 1.21 tons in 1998, which ranked first in the world. Now coal is mined mainly with mechanization in China, which is planned to reach 80% in major State-owned coal mines in 2000 according to the planning of the government (Li et al., 1998; Tang Dejin, 1998).Compared with the USA and Australia, China has more complex coal geological structures. Based on high-resolution seismic technique in coal exploration, a new seismic technique with high-precision and high-resolution (2-D and 3-D) has been developed for the purpose of detecting small geological structures in coal mine construction and production to meet the needs of large-scale popularization of mechanized coal mining in China. The technique is low in cost and requires a relatively short period of exploration, with high precision and wide-range applications. In the middle of the 1980s, it began to be used in pre-mining coal exploration on a trial basis, and entered the peak of exploration in the 1990s, which has made significant progress in providing high-precision geological results for the construction and production of coal industry in China, and is still in the ascendant.This paper discusses some new progress and the exploration capability and application range of the technique.

  1. Development of a facility for high-precision irradiation of cells with carbon ions

    Energy Technology Data Exchange (ETDEWEB)

    Goethem, Marc-Jan van; Niemantsverdriet, Maarten; Brandenburg, Sytze; Langendijk, Johannes A.; Coppes, Robert P.; Luijk, Peter van [Department of Cell Biology, Section of Radiation and Stress Cell Biology, University Medical Center Groningen, University of Groningen, A. Deusinglaan 1, 9713AV Groningen (Netherlands); Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700RB Groningen (Netherlands); Kernfysisch Versneller Instituut, University of Groningen, Zernikelaan 25, 9747AA Groningen (Netherlands); Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700RB Groningen (Netherlands); Department of Cell Biology, Section of Radiation and Stress Cell Biology, University Medical Center Groningen, University of Groningen, A. Deusinglaan 1, 9713AV Groningen (Netherlands); Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700RB Groningen (Netherlands)

    2011-01-15

    Purpose: Compared to photons, using particle radiation in radiotherapy reduces the dose and irradiated volume of normal tissues, potentially reducing side effects. The biological effect of dose deposited by particles such as carbon ions, however, differs from that of dose deposited by photons. The inaccuracy in models to estimate the biological effects of particle radiation remains the most important source of uncertainties in particle therapy. Improving this requires high-precision studies on biological effects of particle radiation. Therefore, the authors aimed to develop a facility for reproducible and high-precision carbon-ion irradiation of cells in culture. The combined dose nonuniformity in the lateral and longitudinal direction should not exceed {+-}1.5%. Dose to the cells from particles than other carbon ions should not exceed 5%. Methods: A uniform lateral dose distribution was realized using a single scatter foil and quadrupole magnets. A modulator wheel was used to create a uniform longitudinal dose distribution. The choice of beam energy and the optimal design of these components was determined using GEANT4 and SRIM Monte Carlo simulations. Verification of the uniformity of the dose distribution was performed using a scintillating screen (lateral) and a water phantom (longitudinal). The reproducibility of dose delivery between experiments was assessed by repeated measurements of the spatial dose distribution. Moreover, the reproducibility of dose-response measurements was tested by measuring the survival of irradiated HEK293 cells in three independent experiments. Results: The relative contribution of dose from nuclear reaction fragments to the sample was found to be <5% when using 90 MeV/u carbon ions. This energy still allows accurate dosimetry conforming to the IAEA Report TRS-398, facilitating comparison to dose-effect data obtained with other radiation qualities. A 1.3 mm long spread-out Bragg peak with a diameter of 30 mm was created, allowing

  2. Universal Axial Fluctuations in Optical Tweezers

    CERN Document Server

    Ribezzi-Crivellari, Marco; Ritort, Felix

    2015-01-01

    Optical tweezers allow the measurement of fluctuations at the nano-scale, in particular fluctuations in the end-to-end distance in single molecules. Fluctuation spectra can yield valuable information, but they can easily be contaminated by instrumental effects. We identify axial fluctuations, i.e. fluctuations of the trapped beads in the direction of light propagation, as one of these instrumental effects. Remarkably, axial fluctuations occur on a characteristic timescale similar to that of conformational (folding) transitions, which may lead to misinterpretation of the experimental results. We show that a precise measurement of the effect of force on both axial and conformational fluctuations is crucial to disentangle them. Our results on axial fluctuations are captured by a simple and general formula valid for all optical tweezers setups and provide experimentalists with a general strategy to distinguish axial fluctuations from conformational transitions.

  3. Light axial vector mesons

    CERN Document Server

    Chen, Kan; Liu, Xiang; Matsuki, Takayuki

    2015-01-01

    Inspired by the abundant experimental observation of axial vector states, we study whether the observed axial vector states can be categorized into the conventional axial vector meson family. In this paper we carry out analysis based on the mass spectra and two-body Okubo-Zweig-Iizuka-allowed decays. Besides testing the possible axial vector meson assignments, we also predict abundant information for their decays and the properties of some missing axial vector mesons, which are valuable to further experimental exploration of the observed and predicted axial vector mesons.

  4. High-Precision Multi-Wave Rectifier Circuit Operating in Low Voltage + 1.5 Volt Current Mode

    Directory of Open Access Journals (Sweden)

    Bancha Burapattanasiri

    2009-12-01

    Full Text Available This article is present high-precision multi-wave rectifier circuit operating in low voltage +/- 1.5 Volt current modes by CMOS technology 0.5 μm, receive input and give output in current mode, respond at high frequency period. The structure compound with high-speed current comparator circuit, current mirror circuit, and CMOS inverter circuit. PSpice program used for confirmation the performance of testing. The PSpice program shows operating of circuit is able to working at maximum input current 400 μAp-p, maximum frequency responding 200 MHz, high precision and low power losses, and non-precision zero crossing output signal.Keywords-component; rectifier circuit; high-precision; low voltage; current mode;

  5. High precision measurement of the {eta} meson mass at COSY-ANKE

    Energy Technology Data Exchange (ETDEWEB)

    Goslawski, Paul

    2013-07-01

    Previous measurements of the {eta} meson mass performed at different experimental facilities resulted in very precise data but differ by up to more than eight standard deviations, i.e., 0.5 MeV/c. Interestingly, the difference seems to be dependent on the measuring method: two missing mass experiments, which produce the {eta} meson in the {sup 3}He{eta} final state, deviate from the recent invariant mass ones. In order to clarify this ambiguous situation a high precision mass measurement was realised at the COSY-ANKE facility. Therefore, a set of deuteron laboratory beam momenta and their associated {sup 3}He centre-of-mass momenta was measured in the dp{yields}{sup 3}HeX reaction near the {eta} production threshold. The {eta} meson was identified by the missing mass peak, whereas its mass was extracted by fixing the production threshold. The individual beam momenta were determined with a relative precision of 3 x 10{sup -5} for values just above 3 GeV/c by using a polarised deuteron beam and inducing an artificial depolarising spin resonance occurring at a well-defined frequency. The final state momenta in the two-body reaction dp{yields}{sup 3}He{eta} were investigated in detail by studying the size of the {sup 3}He momentum sphere with the forward detection system of the ANKE spectrometer. Final alignment and momentum calibration of the spectrometer was achieved by a comprehensive study of the {sup 3}He final state momenta as a function of the centre-of-mass angles, taking advantage of the full geometrical acceptance. The value obtained for the mass at COSY-ANKE m{sub {eta}}=(547.873{+-}0.005{sub stat.}{+-}0.027{sub syst.}) MeV/c{sup 2} is therefore worldwide the most precise one. This mass value is contrary to earlier missing mass experiments but it is consistent and competitive with recent invariant mass measurements, in which the meson was detected through its decay products.

  6. High-precision percolation thresholds and Potts-model critical manifolds from graph polynomials

    Science.gov (United States)

    >Jesper Lykke Jacobsen,

    2014-04-01

    The critical curves of the q-state Potts model can be determined exactly for regular two-dimensional lattices G that are of the three-terminal type. This comprises the square, triangular, hexagonal and bow-tie lattices. Jacobsen and Scullard have defined a graph polynomial PB(q, v) that gives access to the critical manifold for general lattices. It depends on a finite repeating part of the lattice, called the basis B, and its real roots in the temperature variable v = eK - 1 provide increasingly accurate approximations to the critical manifolds upon increasing the size of B. Using transfer matrix techniques, these authors computed PB(q, v) for large bases (up to 243 edges), obtaining determinations of the ferromagnetic critical point vc > 0 for the (4, 82), kagome, and (3, 122) lattices to a precision (of the order 10-8) slightly superior to that of the best available Monte Carlo simulations. In this paper we describe a more efficient transfer matrix approach to the computation of PB(q, v) that relies on a formulation within the periodic Temperley-Lieb algebra. This makes possible computations for substantially larger bases (up to 882 edges), and the precision on vc is hence taken to the range 10-13. We further show that a large variety of regular lattices can be cast in a form suitable for this approach. This includes all Archimedean lattices, their duals and their medials. For all these lattices we tabulate high-precision estimates of the bond percolation thresholds pc and Potts critical points vc. We also trace and discuss the full Potts critical manifold in the (q, v) plane, paying special attention to the antiferromagnetic region v < 0. Finally, we adapt the technique to site percolation as well, and compute the polynomials PB(p) for certain Archimedean and dual lattices (those having only cubic and quartic vertices), using very large bases (up to 243 vertices). This produces the site percolation thresholds pc to a precision of the order of 10-9.

  7. High precision wavelength measurements of QED-sensitive forbidden transitions in highly charged argon ions.

    Science.gov (United States)

    Draganić, I; Crespo López-Urrutia, J R; DuBois, R; Fritzsche, S; Shabaev, V M; Orts, R Soria; Tupitsyn, I I; Zou, Y; Ullrich, J

    2003-10-31

    We present the results of an experimental study of magnetic dipole (M1) transitions in highly charged argon ions (Ar X, Ar XI, Ar XIV, Ar XV) in the visible spectral range using an electron beam ion trap. Their wavelengths were determined with, for highly charged ions, unprecedented accuracy up to the sub-ppm level and compared with theoretical calculations. The QED contributions, calculated in this Letter, are found to be 4 orders of magnitude larger than the experimental error and are absolutely indispensable to bring theory and experiment to a good agreement. This method shows great potential for the study of QED effects in relativistic few-electron systems.

  8. A High Precision Comprehensive Evaluation Method for Flood Disaster Loss Based on Improved Genetic Programming

    Institute of Scientific and Technical Information of China (English)

    ZHOU Yuliang; LU Guihua; JIN Juliang; TONG Fang; ZHOU Ping

    2006-01-01

    Precise comprehensive evaluation of flood disaster loss is significant for the prevention and mitigation of flood disasters. Here, one of the difficulties involved is how to establish a model capable of describing the complex relation between the input and output data of the system of flood disaster loss. Genetic programming (GP) solves problems by using ideas from genetic algorithm and generates computer programs automatically. In this study a new method named the evaluation of the grade of flood disaster loss (EGFD) on the basis of improved genetic programming (IGP) is presented (IGPEGFD). The flood disaster area and the direct economic loss are taken as the evaluation indexes of flood disaster loss. Obviously that the larger the evaluation index value, the larger the corresponding value of the grade of flood disaster loss is. Consequently the IGP code is designed to make the value of the grade of flood disaster be an increasing function of the index value. The result of the application of the IGP-EGFD model to Henan Province shows that a good function expression can be obtained within a bigger searched function space; and the model is of high precision and considerable practical significance.Thus, IGP-EGFD can be widely used in automatic modeling and other evaluation systems.

  9. Development of high precision digital driver of acoustic-optical frequency shifter for ROG

    Science.gov (United States)

    Zhang, Rong; Kong, Mei; Xu, Yameng

    2016-10-01

    We develop a high precision digital driver of the acoustic-optical frequency shifter (AOFS) based on the parallel direct digital synthesizer (DDS) technology. We use an atomic clock as the phase-locked loop (PLL) reference clock, and the PLL is realized by a dual digital phase-locked loop. A DDS sampling clock up to 320 MHz with a frequency stability as low as 10-12 Hz is obtained. By constructing the RF signal measurement system, it is measured that the frequency output range of the AOFS-driver is 52-58 MHz, the center frequency of the band-pass filter is 55 MHz, the ripple in the band is less than 1 dB@3MHz, the single channel output power is up to 0.3 W, the frequency stability is 1 ppb (1 hour duration), and the frequency-shift precision is 0.1 Hz. The obtained frequency stability has two orders of improvement compared to that of the analog AOFS-drivers. For the designed binary frequency shift keying (2-FSK) and binary phase shift keying (2-PSK) modulation system, the demodulating frequency of the input TTL synchronous level signal is up to 10 kHz. The designed digital-bus coding/decoding system is compatible with many conventional digital bus protocols. It can interface with the ROG signal detecting software through the integrated drive electronics (IDE) and exchange data with the two DDS frequency-shift channels through the signal detecting software.

  10. Microsurgery robots: addressing the needs of high-precision surgical interventions.

    Science.gov (United States)

    Mattos, Leonardo S; Caldwell, Darwin G; Peretti, Giorgio; Mora, Francesco; Guastini, Luca; Cingolani, Roberto

    2016-01-01

    Robotics has a significant potential to enhance the overall capacity and efficiency of healthcare systems. Robots can help surgeons perform better quality operations, leading to reductions in the hospitalisation time of patients and in the impact of surgery on their postoperative quality of life. In particular, robotics can have a significant impact on microsurgery, which presents stringent requirements for superhuman precision and control of the surgical tools. Microsurgery is, in fact, expected to gain importance in a growing range of surgical specialties as novel technologies progressively enable the detection, diagnosis and treatment of diseases at earlier stages. Within such scenarios, robotic microsurgery emerges as one of the key components of future surgical interventions, and will be a vital technology for addressing major surgical challenges. Nonetheless, several issues have yet to be overcome in terms of mechatronics, perception and surgeon-robot interfaces before microsurgical robots can achieve their full potential in operating rooms. Research in this direction is progressing quickly and microsurgery robot prototypes are gradually demonstrating significant clinical benefits in challenging applications such as reconstructive plastic surgery, ophthalmology, otology and laryngology. These are reassuring results offering confidence in a brighter future for high-precision surgical interventions.

  11. MEASURING HIGH-PRECISION ASTROMETRY WITH THE INFRARED ARRAY CAMERA ON THE SPITZER SPACE TELESCOPE

    Energy Technology Data Exchange (ETDEWEB)

    Esplin, T. L.; Luhman, K. L., E-mail: taran.esplin@psu.edu [Department of Astronomy and Astrophysics, The Pennsylvania State University, University Park, PA 16802 (United States)

    2016-01-15

    The Infrared Array Camera (IRAC) on the Spitzer Space Telescope currently offers the greatest potential for high-precision astrometry of faint mid-IR sources across arcminute-scale fields, which would be especially valuable for measuring parallaxes of cold brown dwarfs in the solar neighborhood and proper motions of obscured members of nearby star-forming regions. To more fully realize IRAC's astrometric capabilities, we have sought to minimize the largest sources of uncertainty in astrometry with its 3.6 and 4.5 μm bands. By comparing different routines that estimate stellar positions, we have found that Point Response Function (PRF) fitting with the Spitzer Science Center's Astronomical Point Source Extractor produces both the smallest systematic errors from varying intra-pixel sensitivity and the greatest precision in measurements of positions. In addition, self-calibration has been used to derive new 7th and 8th order distortion corrections for the 3.6 and 4.5 μm arrays of IRAC, respectively. These corrections are suitable for data throughout the mission of Spitzer when a time-dependent scale factor is applied to the corrections. To illustrate the astrometric accuracy that can be achieved by combining PRF fitting with our new distortion corrections, we have applied them to archival data for a nearby star-forming region, arriving at total astrometric errors of ∼20 and 70 mas at signal to noise ratios of 100 and 10, respectively.

  12. High Precision CTE-Measurement of SiC-100 for Cryogenic Space-Telescopes

    CERN Document Server

    Enya, K; Onaka, T; Nakagawa, T; Kaneda, H; Hirabayashi, M; Toulemont, Y; Castel, D; Kanai, Y; Fujishiro, N

    2007-01-01

    We present the results of high precision measurements of the thermal expansion of the sintered SiC, SiC-100, intended for use in cryogenic space-telescopes, in which minimization of thermal deformation of the mirror is critical and precise information of the thermal expansion is needed for the telescope design. The temperature range of the measurements extends from room temperature down to $\\sim$ 10 K. Three samples, #1, #2, and #3 were manufactured from blocks of SiC produced in different lots. The thermal expansion of the samples was measured with a cryogenic dilatometer, consisting of a laser interferometer, a cryostat, and a mechanical cooler. The typical thermal expansion curve is presented using the 8th order polynomial of the temperature. For the three samples, the coefficients of thermal expansion (CTE), $\\bar{\\alpha}_{#1}$, $\\bar{\\alpha}_{#2}$, and $\\bar{\\alpha}_{#3}$ were derived for temperatures between 293 K and 10 K. The average and the dispersion (1 $\\sigma$ rms) of these three CTEs are 0.816 an...

  13. High-precision correlative fluorescence and electron cryo microscopy using two independent alignment markers.

    Science.gov (United States)

    Schellenberger, Pascale; Kaufmann, Rainer; Siebert, C Alistair; Hagen, Christoph; Wodrich, Harald; Grünewald, Kay

    2014-08-01

    Correlative light and electron microscopy (CLEM) is an emerging technique which combines functional information provided by fluorescence microscopy (FM) with the high-resolution structural information of electron microscopy (EM). So far, correlative cryo microscopy of frozen-hydrated samples has not reached better than micrometre range accuracy. Here, a method is presented that enables the correlation between fluorescently tagged proteins and electron cryo tomography (cryoET) data with nanometre range precision. Specifically, thin areas of vitrified whole cells are examined by correlative fluorescence cryo microscopy (cryoFM) and cryoET. Novel aspects of the presented cryoCLEM workflow not only include the implementation of two independent electron dense fluorescent markers to improve the precision of the alignment, but also the ability of obtaining an estimate of the correlation accuracy for each individual object of interest. The correlative workflow from plunge-freezing to cryoET is detailed step-by-step for the example of locating fluorescence-labelled adenovirus particles trafficking inside a cell. © 2013 Published by Elsevier B.V.

  14. High-Precision Isotope Ratio Measurements of Sub-Picogram Actinide Samples

    Science.gov (United States)

    Pollington, A. D.; Kinman, W.

    2016-12-01

    One of the most exciting trends in analytical geochemistry over the past decade is the push towards smaller and smaller sample sizes while simultaneously achieving high precision isotope ratio measurements. This trend has been driven by advances in clean chemistry protocols, and by significant breakthroughs in mass spectrometer ionization efficiency and detector quality (stability and noise for low signals). In this presentation I will focus on new techniques currently being developed at Los Alamos National Laboratory for the characterization of ultra-small samples (pg, fg, ag), with particular focus on actinide measurements by MC-ICP-MS. Analyses of U, Pu, Th and Am are routinely carried out in our facility using multi-ion counting techniques. I will describe some of the challenges associated with using exclusively ion counting methods (e.g., stability, detector cross calibration, etc.), and how we work to mitigate them. While the focus of much of the work currently being carried out is in the broad field of nuclear forensics and safeguards, the techniques that are being developed are directly applicable to many geologic questions that require analyses of small samples of U and Th, for example. In addition to the description of the technique development, I will present case studies demonstrating the precision and accuracy of the method as applied to real-world samples.

  15. High-precision satellite relative-trajectory simulating servosystem for inter-satellite laser communications

    Science.gov (United States)

    Zhang, Lei; Liu, Liren; Luan, Zhu; Liu, Hongzhan; Xu, Rongwei

    2004-10-01

    Because PAT (pointing-acquisition-tracking) parameters and integrated technical specifications of laser communication terminals for inter-satellite link must be pre-verified and assessed thoroughly on a ground-based test-bed before launched into the space, it is necessary to develop a system as a primary part of the test bed to simulate the relative trajectory between the satellites. In this paper, an original high-precision satellite relative-trajectory simulating servosystem is introduced in detail as well as its structures and characteristics. The system is used to simulate the motion of relative-trajectory between satellites in different orbits. The principle of the system is to import the data of two satellites" orbits into a computer-based control system in advance. After processed and analyzed, the data is transformed into the angular displacement of the servomotor which drives the gimbal directly. The angular displacement of the two axes of the gimbal can simulate precisely the relative-trajectory, namely elevation angle and azimuth angle of the two satellites in communication. A laser communication terminal mounted on the gimbal then performs the PAT mechanisms to evaluate the system"s capacity.

  16. Tracking Perfluorocarbon Nanoemulsion Delivery by 19F MRI for Precise High Intensity Focused Ultrasound Tumor Ablation

    Science.gov (United States)

    Shin, Soo Hyun; Park, Eun-Joo; Min, Changki; Choi, Sun Il; Jeon, Soyeon; Kim, Yun-Hee; Kim, Daehong

    2017-01-01

    Perfluorocarbon nanoemulsions (PFCNEs) have recently been undergoing rigorous study to investigate their ability to improve the therapeutic efficacy of tumor ablation by high intensity focused ultrasound (HIFU). For precise control of PFCNE delivery and thermal ablation, their accumulation and distribution in a tumor should be quantitatively analyzed. Here, we used fluorine-19 (19F) magnetic resonance imaging (MRI) to quantitatively track PFCNE accumulation in a tumor, and analyzed how intra-tumoral PFCNE quantities affect the therapeutic efficacy of HIFU treatment. Ablation outcomes were assessed by intra-voxel incoherent motion analysis and bioluminescent imaging up to 14 days after the procedure. Assessment of PFCNE delivery and treatment outcomes showed that 2-3 mg/mL of PFCNE in a tumor produces the largest ablation volume under the same HIFU insonation conditions. Histology showed varying degrees of necrosis depending on the amount of PFCNE delivered. 19F MRI promises to be a valuable platform for precisely guiding PFCNE-enhanced HIFU ablation of tumors. PMID:28255351

  17. Development of a High-Precision Touch-Trigger Probe Using a Single Sensor

    Directory of Open Access Journals (Sweden)

    Rui-Jun Li

    2016-03-01

    Full Text Available To measure various components with nano-scale precision, a new high-precision touch-trigger probe using a single low-cost sensor for a micro-coordinate measuring machine (CMM is presented in this paper. The sensor is composed of a laser diode, a plane mirror, a focusing lens, and a quadrant photo detector (QPD. The laser beam from the laser diode with an incident angle is reflected by the plane mirror and then projected onto the quadrant photo detector (QPD via the focusing lens. The plane mirror is adhered to the upper surface of the floating plate supported by an elastic mechanism, which can transfer the displacement of the stylus’s ball tip in 3D to the plane mirror’s vertical and tilt movement. Both motions of the plane mirror can be detected by respective QPDs. The probe mechanism was analyzed, and its structural parameters that conform to the principle of uniform sensitivity and uniform stiffness were obtained. The simulation result showed that the stiffness was equal in 3D and less than 1 mN/µm. Some experiments were performed to investigate the probe’s characteristics. It was found that the probe could detect the trigger point with uniform sensitivity, a resolution of less than 5 nm, and a repeatability of less than 4 nm. It can be used as a touch-trigger probe on a micro/nano-CMM.

  18. Towards an unbiased filter routine to determine precipitation and evapotranspiration from high precision lysimeter measurements

    Science.gov (United States)

    Peters, Andre; Groh, Jannis; Schrader, Frederik; Durner, Wolfgang; Vereecken, Harry; Pütz, Thomas

    2017-06-01

    Weighing lysimeters are considered to be the best means for a precise measurement of water fluxes at the interface between the soil-plant system and the atmosphere. Any decrease of the net mass of the lysimeter can be interpreted as evapotranspiration (ET), any increase as precipitation (P). However, the measured raw data need to be filtered to separate real mass changes from noise. Such filter routines typically apply two steps: (i) a low pass filter, like moving average, which smooths noisy data, and (ii) a threshold filter that separates significant from insignificant mass changes. Recent developments of these filters have identified and solved some problems regarding bias in the data processing. A remaining problem is that each change in flow direction is accompanied with a systematic flow underestimation due to the threshold scheme. In this contribution, we analyze this systematic effect and show that the absolute underestimation is independent of the magnitude of a flux event. Thus, for small events, like dew or rime formation, the relative error is high and can reach the same magnitude as the flux itself. We develop a heuristic solution to the problem by introducing a so-called ;snap routine;. The routine is calibrated and tested with synthetic flux data and applied to real measurements obtained with a precision lysimeter for a 10-month period. The heuristic snap routine effectively overcomes these problems and yields an almost unbiased representation of the real signal.

  19. High-precision radiocarbon dating and historical biblical archaeology in southern Jordan.

    Science.gov (United States)

    Levy, Thomas E; Higham, Thomas; Bronk Ramsey, Christopher; Smith, Neil G; Ben-Yosef, Erez; Robinson, Mark; Münger, Stefan; Knabb, Kyle; Schulze, Jürgen P; Najjar, Mohammad; Tauxe, Lisa

    2008-10-28

    Recent excavations and high-precision radiocarbon dating from the largest Iron Age (IA, ca. 1200-500 BCE) copper production center in the southern Levant demonstrate major smelting activities in the region of biblical Edom (southern Jordan) during the 10th and 9th centuries BCE. Stratified radiocarbon samples and artifacts were recorded with precise digital surveying tools linked to a geographic information system developed to control on-site spatial analyses of archaeological finds and model data with innovative visualization tools. The new radiocarbon dates push back by 2 centuries the accepted IA chronology of Edom. Data from Khirbat en-Nahas, and the nearby site of Rujm Hamra Ifdan, demonstrate the centrality of industrial-scale metal production during those centuries traditionally linked closely to political events in Edom's 10th century BCE neighbor ancient Israel. Consequently, the rise of IA Edom is linked to the power vacuum created by the collapse of Late Bronze Age (LB, ca. 1300 BCE) civilizations and the disintegration of the LB Cypriot copper monopoly that dominated the eastern Mediterranean. The methodologies applied to the historical IA archaeology of the Levant have implications for other parts of the world where sacred and historical texts interface with the material record.

  20. Measuring High-Precision Astrometry with the Infrared Array Camera on the Spitzer Space Telescope

    CERN Document Server

    Esplin, T L

    2015-01-01

    The Infrared Array Camera (IRAC) on the Spitzer Space Telescope currently offers the greatest potential for high-precision astrometry of faint mid-IR sources across arcminute-scale fields, which would be especially valuable for measuring parallaxes of cold brown dwarfs in the solar neighborhood and proper motions of obscured members of nearby star-forming regions. To more fully realize IRAC's astrometric capabilities, we have sought to minimize the largest sources of uncertainty in astrometry with its 3.6 and 4.5 $\\mu$m bands. By comparing different routines that estimate stellar positions, we have found that Point Response Function (PRF) fitting with the Spitzer Science Center's Astronomical Point Source Extractor produces both the smallest systematic errors from varying intra-pixel sensitivity and the greatest precision in measurements of positions. In addition, self-calibration has been used to derive new 7$^{\\rm th}$ and 8$^{\\rm th}$ order distortion corrections for the 3.6 and 4.5 $\\mu$m arrays of IRAC, ...