WorldWideScience

Sample records for high pollution loads

  1. Pollution loads in urban runoff and sanitary wastewater.

    Science.gov (United States)

    Taebi, Amir; Droste, Ronald L

    2004-07-05

    While more attention has been paid in recent years to urban point source pollution control through the establishment of wastewater treatment plants in many developing countries, no considerable planning nor any serious measures have been taken to control urban non-point source pollution (urban stormwater runoff). The present study is a screening analysis to investigate the pollution loads in urban runoff compared to point source loads as a first prerequisite for planning and management of receiving water quality. To compare pollutant loads from point and non-point urban sources, the pollutant load is expressed as the weight of pollutant per hectare area per year (kg/ha.year). Unit loads were estimated in stormwater runoff, raw sanitary wastewater and secondary treatment effluents in Isfahan, Iran. Results indicate that the annual pollution load in urban runoff is lower than the annual pollution load in sanitary wastewater in areas with low precipitation but it is higher in areas with high precipitation. Two options, namely, advanced treatment (in lieu of secondary treatment) of sanitary wastewater and urban runoff quality control systems (such as detention ponds) were investigated as controlling systems for pollution discharges into receiving waters. The results revealed that for Isfahan, as a low precipitation urban area, advanced treatment is a more suitable option, but for high precipitation urban areas, urban surface runoff quality control installations were more effective for suspended solids and oxygen-demanding matter controls, and that advanced treatment is the more effective option for nutrient control.

  2. Pollution loads in urban runoff and sanitary wastewater

    International Nuclear Information System (INIS)

    Taebi, Amir; Droste, Ronald L.

    2004-01-01

    While more attention has been paid in recent years to urban point source pollution control through the establishment of wastewater treatment plants in many developing countries, no considerable planning nor any serious measures have been taken to control urban non-point source pollution (urban stormwater runoff). The present study is a screening analysis to investigate the pollution loads in urban runoff compared to point source loads as a first prerequisite for planning and management of receiving water quality. To compare pollutant loads from point and non-point urban sources, the pollutant load is expressed as the weight of pollutant per hectare area per year (kg/ha·year). Unit loads were estimated in stormwater runoff, raw sanitary wastewater and secondary treatment effluents in Isfahan, Iran. Results indicate that the annual pollution load in urban runoff is lower than the annual pollution load in sanitary wastewater in areas with low precipitation but it is higher in areas with high precipitation. Two options, namely, advanced treatment (in lieu of secondary treatment) of sanitary wastewater and urban runoff quality control systems (such as detention ponds) were investigated as controlling systems for pollution discharges into receiving waters. The results revealed that for Isfahan, as a low precipitation urban area, advanced treatment is a more suitable option, but for high precipitation urban areas, urban surface runoff quality control installations were more effective for suspended solids and oxygen-demanding matter controls, and that advanced treatment is the more effective option for nutrient control

  3. Industrial pollution load assessment in Phnom Penh, Cambodia using an industrial pollution projection system.

    Science.gov (United States)

    San, Vibol; Spoann, Vin; Schmidt, Johannes

    2018-02-15

    Approximately 56% out of the total 1302 Cambodian firms are operated in the Capital city of Cambodia. The necessary information on industrial pollution to set strategies, priorities and action plans on environmental protection issues is absent in Cambodia. In the absence of this data, effective environmental protection cannot be implemented. The objective of this study is to estimate industrial pollution load by employing the Industrial Pollution Projection System, a rapid environmental management tool for assessment of pollution load, to produce a scientific rational basis for preparing future policy direction to reduce industrial pollution in Phnom Penh city. Factory data between 1994 and 2014 obtained from the Ministry of Industry and Handicraft of Cambodia were used in our study. Due to the high number of employees, the total environmental load generated in Phnom Penh city was estimated to be 476,981Mg in 2014. Phnom Penh city generated 189,109Mg of VOC, 165,411Mg of toxic chemicals to air, 38,523Mg of toxic chemicals to land, and 28,968Mg of SO 2 in 2014. The results of the estimation show that the Textiles and Apparel sector was the highest generators of toxic chemicals into land and air, and toxic metals into land, air and water, while the Basic Metal sector was the greatest contributor of toxic chemicals to water. The Textiles and Apparel sector alone emitted 436,016Mg of total pollution load. The results indicate that the Dangkao and Meanchey districts were the greatest emitters of all pollutants in Phnom Penh. The results suggest that reduction in industrial pollution could be achieved by focusing on the most polluting sectors and areas. Adopting waste minimization strategies, which include cleaner production processes, will not only reduce the cost of controlling pollution, it will also make manufacturing more efficient thereby increasing profits while reducing pollution load in the long run. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Pollution loads from stormwater overflows

    International Nuclear Information System (INIS)

    Bonomo, L.

    1991-01-01

    The knowledge of the volume of combined effluents outflowing from overflows is not enough to allow a direct evaluation of polluting loads discharged into final receptors; the hypothesis of complete mixing between sewage and stormwater flow, fed in at a pollutant concentration level equal to zero, hasn't proved to be successful. The amount of the outflowing loads largely depends on the contamination of the stormwater runoff before inflow into the drainage system and on sedimentation and resuspension phenomena. This paper reports the main aspects connected with wet and dry atmospheric deposition of pollutants and with paved surface wash-out phenomena. The origin of pollutants flush, due to the resuspension and mass transport of polluting substances stored up in the sewer during draughts, is also described. Attention is drawn to the importance of the behaviour of the different pollutants with respect to the sedimentation phenomena. Reference is made to evaluations conducted on a drainage system for the recovery of a small pre-alpine lake

  5. Greywater pollution variability and loadings

    DEFF Research Database (Denmark)

    Eriksson, Eva; Andersen, Henrik Rasmus; Madsen, Toke S.

    2009-01-01

    Small on-site greywater treatment and reuse plants are susceptible to high short-term variation in flow and pollutant concentrations. As demonstrated in this study of a bathroom greywater plant in Copenhagen, Denmark, the flow ranges from no-flow periods to high-flow periods reaching 34 l min−1...... per day, whereas the paraben loadings were below 1 mg per person per day. These data are highly relevant for comparing decentralised treatment options with existing end-of-pipe treatments, for feeding into risk assessments and for design purposes....

  6. Using remotely sensed imagery to estimate potential annual pollutant loads in river basins.

    Science.gov (United States)

    He, Bin; Oki, Kazuo; Wang, Yi; Oki, Taikan

    2009-01-01

    Land cover changes around river basins have caused serious environmental degradation in global surface water areas, in which the direct monitoring and numerical modeling is inherently difficult. Prediction of pollutant loads is therefore crucial to river environmental management under the impact of climate change and intensified human activities. This research analyzed the relationship between land cover types estimated from NOAA Advanced Very High Resolution Radiometer (AVHRR) imagery and the potential annual pollutant loads of river basins in Japan. Then an empirical approach, which estimates annual pollutant loads directly from satellite imagery and hydrological data, was investigated. Six water quality indicators were examined, including total nitrogen (TN), total phosphorus (TP), suspended sediment (SS), Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD), and Dissolved Oxygen (DO). The pollutant loads of TN, TP, SS, BOD, COD, and DO were then estimated for 30 river basins in Japan. Results show that the proposed simulation technique can be used to predict the pollutant loads of river basins in Japan. These results may be useful in establishing total maximum annual pollutant loads and developing best management strategies for surface water pollution at river basin scale.

  7. A Web-Based Tool to Estimate Pollutant Loading Using LOADEST

    Directory of Open Access Journals (Sweden)

    Youn Shik Park

    2015-09-01

    Full Text Available Collecting and analyzing water quality samples is costly and typically requires significant effort compared to streamflow data, thus water quality data are typically collected at a low frequency. Regression models, identifying a relationship between streamflow and water quality data, are often used to estimate pollutant loads. A web-based tool using LOAD ESTimator (LOADEST as a core engine with four modules was developed to provide user-friendly interfaces and input data collection via web access. The first module requests and receives streamflow and water quality data from the U.S. Geological Survey. The second module retrieves watershed area for computation of pollutant loads per unit area. The third module examines potential error of input datasets for LOADEST runs, and the last module computes estimated and allowable annual average pollutant loads and provides tabular and graphical LOADEST outputs. The web-based tool was applied to two watersheds in this study, one agriculturally-dominated and one urban-dominated. It was found that annual sediment load at the urban-dominant watershed exceeded the target load; therefore, the web-based tool identified correctly the watershed requiring best management practices to reduce pollutant loads.

  8. Loading functions for assessment of water pollution from nonpoint sources

    International Nuclear Information System (INIS)

    McElroy, A.D.; Chiu, S.Y.; Nebgen, J.W.; Aleti, A.; Bennett, F.W.

    1976-05-01

    Methods for evaluating the quantity of water pollutants generated from nonpoint sources including agriculture, silviculture, construction, mining, runoff from urban areas and rural roads, and terrestrial disposal are developed and compiled for use in water quality planning. The loading functions, plus in some instances emission values, permit calculation of nonpoint source pollutants from available data and information. Natural background was considered to be a source and loading functions were presented to estimate natural or background loads of pollutants. Loading functions/values are presented for average conditions, i.e., annual average loads expressed as metric tons/hectare/year (tons/acre/year). Procedures for estimating seasonal or 30-day maximum and minimum loads are also presented. In addition, a wide variety of required data inputs to loading functions, and delineation of sources of additional information are included in the report. The report also presents an evaluation of limitations and constraints of various methodologies which will enable the user to employ the functions realistically

  9. Rainfall Deduction Method for Estimating Non-Point Source Pollution Load for Watershed

    OpenAIRE

    Cai, Ming; Li, Huai-en; KAWAKAMI, Yoji

    2004-01-01

    The water pollution can be divided into point source pollution (PSP) and non-point source pollution (NSP). Since the point source pollution has been controlled, the non-point source pollution is becoming the main pollution source. The prediction of NSP load is being increasingly important in water pollution controlling and planning in watershed. Considering the monitoring data shortage of NPS in China, a practical estimation method of non-point source pollution load --- rainfall deduction met...

  10. [Effect of antecedent dry weather period on urban storm runoff pollution load].

    Science.gov (United States)

    Li, Li-qing; Yin, Cheng-qing; Kong, Ling-li; He, Qing-ci

    2007-10-01

    Twelve storm events were surveyed at Shilipu catchment in Wuhan City through three-year monitoring regime. The flow discharges, total suspended solids (TSS), chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP) in runoff were measured to study the mechanism of urban stormwater runoff pollution. The relationship between the event pollution load and the antecedent dry weather period was identified to discuss the influence of the urban surface sanitation management, operation of sewer pipe maintenance and rainfall characteristics on the urban stormwater runoff pollution. It was found that the antecedent dry weather period and runoff amount were the important determining factors in the generation of urban stormwater runoff pollution. The event pollution load was positively correlated to the antecedent dry weather period between two rainfall events (R2 = 0.95, p pollution loads. The best regression equation to estimate pollution load for storm events was developed based on the antecedent dry weather period and runoff depth. Source control including improving urban street sweeping activities and operation of sewer pipe maintenance should be made to reduce the amount of available pollutant over the dry days. It is important alternative to control urban stormwater runoff pollution for Hanyang District.

  11. Fifth Baltic Sea pollution load compilation (PLC-5). An executive summary

    Energy Technology Data Exchange (ETDEWEB)

    Svendsen, L.M.; Staaf, H.; Pyhala, M.; Kotilainen, P.; Bartnicki, J.; Knuuttila, S.; Durkin, M.

    2012-07-01

    This report summarizes and combines the main results of the Fifth Baltic Sea Pollution Load Compilation (HELCOM 2011) which covers waterborne loads to the sea and data on atmospheric loads which are submitted by countries to the co-operative programme for monitoring and evaluation of the long range transmission of air pollutants in Europe (EMEP), which subsequently compiles and reports this information to HELCOM.

  12. Estimation of metal pollutant loads from Nuclear and Energy Research Institute (Brazil)

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Joyce R.; Monteiro, Lucilena R.; Soares, Sabrina M.V.; Stellato, Thamiris B.; Silva, Tatiane B.S.C.; Silva, Douglas B. da; Faustino, Mainara G.; Pires, Maria A.F.; Cotrim, Marycel E.B., E-mail: joyce.marques@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    According to National Environmental Council's (CONAMA) Resolution 357/05, pollutant load can be defined as the amount of a particular pollutant released in receiving water body; it is commonly expressed in a mass-time ratio. As specified in CONAMA's Resolution 430/11, the responsible for the pollutant source must present the Pollutant Load Declaration to environmental authorities. However, pollutant load knowledge is also important to the water quality maintenance and its environmental rating that must be kept to meet the requirements of the most restrictive use. In the control of metals releases is also important due public health matters, since they can cause harmful environmental contamination and major public health issues. Therefore this work aims to present the estimated metal pollutant load released by Nuclear and Energy Research Institute (IPEN/CNEN - Brazil), between 2013 and 2014. Results of cadmium, lead, copper, chromium, zinc, nickel, manganese, iron, barium, silver, boron and tin in composite samples (weekly) via Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) and bromide (Br-) released as a tracer, to measure the wastewater flow were used to estimate IPEN's Metal Pollutant load. This study is part of the environmental assessment Program at IPEN, instituted since 2006 to the attendance of the current environmental legislation (CONAMA's Resolution 430/11, Article 19-A of State Decree 8.468/76 and State Decree 15.425/80). (author)

  13. Loading functions for assessment of water pollution from nonpoint sources. Final report

    International Nuclear Information System (INIS)

    McElroy, A.D.; Chiu, S.Y.; Nebgen, J.W.; Aleti, A.; Bennett, F.W.

    1976-05-01

    Methods for evaluating the quantity of water pollutants generated from nonpoint sources including agriculture, silviculture, construction, mining, runoff from urban areas and rural roads, and terrestrial disposal are developed and compiled for use in water quality planning. The loading functions, plus in some instances emission values, permit calculation of nonpoint source pollutants from available data and information. Natural background was considered to be a source and loading functions were presented to estimate natural or background loads of pollutants. Loading functions/values are presented for average conditions, i.e., annual average loads expressed as metric tons/hectare/year (tons/acre/year). Procedures for estimating seasonal or 30-day maximum and minimum loads are also presented. In addition, a wide variety of required data inputs to loading functions, and delineation of sources of additional information are included in the report. The report also presents an evaluation of limitations and constraints of various methodologies which will enable the user to employ the functions realistically

  14. Pollutant concentrations and pollution loads in stormwater runoff from different land uses in Chongqing.

    Science.gov (United States)

    Wang, Shumin; He, Qiang; Ai, Hainan; Wang, Zhentao; Zhang, Qianqian

    2013-03-01

    To investigate the distribution of pollutant concentrations and pollution loads in stormwater runoff in Chongqing, six typical land use types were selected and studied from August 2009 to September 2011. Statistical analysis on the distribution of pollutant concentrations in all water samples shows that pollutant concentrations fluctuate greatly in rainfall-runoff, and the concentrations of the same pollutant also vary greatly in different rainfall events. In addition, it indicates that the event mean concentrations (EMCs) of total suspended solids (TSS) and chemical oxygen demand (COD) from urban traffic roads (UTR) are significantly higher than those from residential roads (RR), commercial areas (CA), concrete roofs (CR), tile roofs (TRoof), and campus catchment areas (CCA); and the EMCs of total phosphorus (TP) and NH3-N from UTR and CA are 2.35-5 and 3 times of the class-II standard values specified in the Environmental Quality Standards for Surface Water (GB 3838-2002). The EMCs of Fe, Pb and Cd are also much higher than the class-III standard values. The analysis of pollution load producing coefficients (PLPC) reveals that the main pollution source of TSS, COD and TP is UTR. The analysis of correlations between rainfall factors and EMCs/PLPC indicates that rainfall duration is correlated with EMCs/PLPC of TSS for TRoof and TP for UTR, while rainfall intensity is correlated with EMCs/PLPC of TP for both CR and CCA. The results of this study provide a reference for better management of non-point source pollution in urban regions.

  15. Comparison of point-source pollutant loadings to soil and groundwater for 72 chemical substances.

    Science.gov (United States)

    Yu, Soonyoung; Hwang, Sang-Il; Yun, Seong-Taek; Chae, Gitak; Lee, Dongsu; Kim, Ki-Eun

    2017-11-01

    Fate and transport of 72 chemicals in soil and groundwater were assessed by using a multiphase compositional model (CompFlow Bio) because some of the chemicals are non-aqueous phase liquids or solids in the original form. One metric ton of chemicals were assumed to leak in a stylized facility. Scenarios of both surface spills and subsurface leaks were considered. Simulation results showed that the fate and transport of chemicals above the water table affected the fate and transport of chemicals below the water table, and vice versa. Surface spill scenarios caused much less concentrations than subsurface leak scenarios because leaching amounts into the subsurface environment were small (at most 6% of the 1 t spill for methylamine). Then, simulation results were applied to assess point-source pollutant loadings to soil and groundwater above and below the water table, respectively, by multiplying concentrations, impact areas, and durations. These three components correspond to the intensity of contamination, mobility, and persistency in the assessment of pollutant loading, respectively. Assessment results showed that the pollutant loadings in soil and groundwater were linearly related (r 2  = 0.64). The pollutant loadings were negatively related with zero-order and first-order decay rates in both soil (r = - 0.5 and - 0.6, respectively) and groundwater (- 1.0 and - 0.8, respectively). In addition, this study scientifically defended that the soil partitioning coefficient (K d ) significantly affected the pollutant loadings in soil (r = 0.6) and the maximum masses in groundwater (r = - 0.9). However, K d was not a representative factor for chemical transportability unlike the expectation in chemical ranking systems of soil and groundwater pollutants. The pollutant loadings estimated using a physics-based hydrogeological model provided a more rational ranking for exposure assessment, compared to the summation of persistency and transportability scores in

  16. An improved risk-explicit interval linear programming model for pollution load allocation for watershed management.

    Science.gov (United States)

    Xia, Bisheng; Qian, Xin; Yao, Hong

    2017-11-01

    Although the risk-explicit interval linear programming (REILP) model has solved the problem of having interval solutions, it has an equity problem, which can lead to unbalanced allocation between different decision variables. Therefore, an improved REILP model is proposed. This model adds an equity objective function and three constraint conditions to overcome this equity problem. In this case, pollution reduction is in proportion to pollutant load, which supports balanced development between different regional economies. The model is used to solve the problem of pollution load allocation in a small transboundary watershed. Compared with the REILP original model result, our model achieves equity between the upstream and downstream pollutant loads; it also overcomes the problem of greatest pollution reduction, where sources are nearest to the control section. The model provides a better solution to the problem of pollution load allocation than previous versions.

  17. [Characteristics and loads of key sources of pollutions discharged into Beishi River, Changzhou City].

    Science.gov (United States)

    Li, Chun-Ping; Jiang, Jian-Guo; Chen, Ai-Mei; Wu, Jia-Ling; Fan, Xiu-Juan; Ye, Bin

    2010-11-01

    Choosing the Beishi river, Changzhou City as the study area, the sewage generation, pollutants characteristics and sewage discharge in catchment area of Beishi river were conducted, detailed investigated and monitored. After using pollution coefficients, the yearly loads of all sources of pollutions were calculated to determine the highest sewage. The results showed that: except pH, the high concentration of SS, COD, BOD5, ammonia nitrogen, TN and TP discharged from MSW collecting houses, MSW transfer stations, public toilets and dining in Changzhou city far exceeded the "Integrated Wastewater Discharge Standard" (GB 8978-1996) and "Effluent Discharged into the City Sewer Water Quality Standards" (CJ 3082-1999). Among which: the highest concentration of COD discharged from MSW transfer stations was up to 51 700 mg/L, while the ammonia nitrogen and TN were as high as 1 616 mg/L and 2 044 mg/L in the toilet wastewater. In addition to this, the ratio of wastewater discharged directly into the river through storm water pipe network was higher from MSW houses, MSW transfer stations, public toilets, dining and other waste in Changzhou city. The 125.2 t/a of COD and 40.53 t/a of BOD5 were the two highest concentrations of various sources of pollution. The highest annual polluting loads discharged into Beishi river is dining, followed by the sanitation facilities. Therefore, cutting pollution control of food and sanitation facilities along the river is particularly urgent.

  18. A pollutant load hierarchical allocation method integrated in an environmental capacity management system for Zhushan Bay, Taihu Lake.

    Science.gov (United States)

    Liang, Shidong; Jia, Haifeng; Yang, Cong; Melching, Charles; Yuan, Yongping

    2015-11-15

    An environmental capacity management (ECM) system was developed to help practically implement a Total Maximum Daily Load (TMDL) for a key bay in a highly eutrophic lake in China. The ECM system consists of a simulation platform for pollutant load calculation and a pollutant load hierarchical allocation (PLHA) system. The simulation platform was developed by linking the Environmental Fluid Dynamics Code (EFDC) and Water Quality Analysis Simulation Program (WASP). In the PLHA, pollutant loads were allocated top-down in several levels based on characteristics of the pollutant sources. Different allocation methods could be used for the different levels with the advantages of each method combined over the entire allocation. Zhushan Bay of Taihu Lake, one of the most eutrophic lakes in China, was selected as a case study. The allowable loads of total nitrogen, total phosphorus, ammonia, and chemical oxygen demand were found to be 2122.2, 94.9, 1230.4, and 5260.0 t·yr(-1), respectively. The PLHA for the case study consists of 5 levels. At level 0, loads are allocated to those from the lakeshore direct drainage, atmospheric deposition, internal release, and tributary inflows. At level 1 the loads allocated to tributary inflows are allocated to the 3 tributaries. At level 2, the loads allocated to one inflow tributary are allocated to upstream areas and local sources along the tributary. At level 3, the loads allocated to local sources are allocated to the point and non-point sources from different towns. At level 4, the loads allocated to non-point sources in each town are allocated to different villages. Compared with traditional forms of pollutant load allocation methods, PLHA can combine the advantages of different methods which put different priority weights on equity and efficiency, and the PLHA is easy to understand for stakeholders and more flexible to adjust when applied in practical cases. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Water Quality Assessment and Determining the Carrying Capacity of Pollution Load Batang Kuranji River

    Science.gov (United States)

    Dewata, I.; Adri, Z.

    2018-04-01

    This study aims to determine the water quality and carrying capacity of pollution load Batang Kuranji River in the headwaters, middle, and downstream. This research is descriptive quantitative parameters of pH, BOD, COD, TSS, and DOES Depictions of river water quality refer to RegulationNo.82/2001, while determination of carrying capacity of pollution load river refers to the Kep Men LHNo.10/2003.The result is Kuranji Batang River water quality upstream region included in either category who meet the quality standard first class ofPP82/2001. TSS concentrations at head waters of 21 mg/L, BOD1,6 mg/L, COD7,99mg/L and DO 7,845 mg/L. While the carrying capacity of pollution load river in upstream region included in both categories namely BOD of 4,4 kg/sec, COD 273,60 kg/sec, TSS906,00kg/sec, and DO parameters of 49.20 kg/sec. Middle region (point 2, 3, and 4) water quality Batang Kuranji River has exceeded the quality standard of 82/2001 for class II and class III. Meanwhile, carrying capacity of pollution load river in area included in ugly category. The calculation is done with application Qual2Kw show that carrying capacity of pollution load river of BOD -857.3 kg/sec, COD -777.40 kg/sec, TSS +9511.5 kg/sec, and DO +69.30 kg/sec.

  20. Runoff quality and pollution loadings from a tropical urban catchment.

    Science.gov (United States)

    Yusop, Z; Tan, L W; Ujang, Z; Mohamed, M; Nasir, K A

    2005-01-01

    Runoff quality draining from 17.14 km2 urban catchment in Johor Bahru, Malaysia, was analysed. The land-use consists of residential (30.3%), agricultural (27.3%), open space (27.9%), industrial (8.1%) and commercial (6.4%) areas. Three storm events were sampled in detail. These storms produced stormflow between 0.84 mm and 27.82 mm, and peakflow from 2.19 m3/s to 42.36 m3/s. Water quality showed marked variation during storms especially for TSS, BOD and COD with maximum concentrations of 778 mg/l, 135 mg/l and 358 mg/l, respectively. Concentrations of TOC, DOC, NH3-N, Fe and level of colour were also high. In general, the river quality is badly polluted and falls in Class V based on the Malaysian Interim National Water Quality Standards. Event Mean Concentrations (EMC) for various parameters varied considerably between storms. The largest storm produced higher EMC for TSS, NO3-N and SS whereas the smaller storms tend to register higher EMC for BOD, COD, NH3-N, TOC, Ca, K, Mg, Fe and Zn. Such variations could be explained in terms of pollutant availability and the effects of flushing and dilution. Based on a three-month average recurrence interval (ARI) of rainfall, the estimated event loadings (ton/ha) of TSS, BOD, COD, TOC, NH3-N and NO3-N were 0.055, 0.016, 0.012, 0.039, 0.010, 0.0007 and 0.0002, respectively. Heavy metals present in trace quantities. Storms with 3 months ARI could capture about 70% of the total annual loads of major pollutants.

  1. The use of simulated rainfall to study the discharge process and the influence factors of urban surface runoff pollution loads.

    Science.gov (United States)

    Qinqin, Li; Qiao, Chen; Jiancai, Deng; Weiping, Hu

    2015-01-01

    An understanding of the characteristics of pollutants on impervious surfaces is essential to estimate pollution loads and to design methods to minimize the impacts of pollutants on the environment. In this study, simulated rainfall equipment was constructed to investigate the pollutant discharge process and the influence factors of urban surface runoff (USR). The results indicated that concentrations of total suspended solids (TSS), total nitrogen (TN), total phosphorus (TP) and chemical oxygen demand (COD) appeared to be higher in the early period and then decreased gradually with rainfall duration until finally stabilized. The capacity and particle size of surface dust, rainfall intensity and urban surface slopes affected runoff pollution loads to a variable extent. The loads of TP, TN and COD showed a positive relationship with the surface dust capacity, whereas the maximum TSS load appeared when the surface dust was 0.0317 g·cm⁻². Smaller particle sizes (pollution carrying capacity of runoff, leading to higher pollution loads. Knowledge of the influence factors could assist in the management of USR pollution loads.

  2. Critical loads as a policy tool for protecting ecosystems from the effects of air pollutants

    Science.gov (United States)

    Douglas A. Burns; Tamara Blett; Richard Haeuber; Linda H. Pardo

    2008-01-01

    Framing the effects of air pollutants on ecosystems in terms of a "critical load" provides a meaningful approach for research scientists to communicate policy-relevant science to air-quality policy makers and natural resource managers. A critical-loads approach has been widely used to shape air-pollutant control policy in Europe since the 1980s, yet has only...

  3. Stormwater Runoff Pollutant Loading Distributions and Their Correlation with Rainfall and Catchment Characteristics in a Rapidly Industrialized City

    Science.gov (United States)

    Li, Dongya; Wan, Jinquan; Ma, Yongwen; Wang, Yan; Huang, Mingzhi; Chen, Yangmei

    2015-01-01

    Fast urbanization and industrialization in developing countries result in significant stormwater runoff pollution, due to drastic changes in land-use, from rural to urban. A three-year study on the stormwater runoff pollutant loading distributions of industrial, parking lot and mixed commercial and residential catchments was conducted in the Tongsha reservoir watershed of Dongguan city, a typical, rapidly industrialized urban area in China. This study presents the changes in concentration during rainfall events, event mean concentrations (EMCs) and event pollution loads per unit area (EPLs). The first flush criterion, namely the mass first flush ratio (MFFn), was used to identify the first flush effects. The impacts of rainfall and catchment characterization on EMCs and pollutant loads percentage transported by the first 40% of runoff volume (FF40) were evaluated. The results indicated that the pollutant wash-off process of runoff during the rainfall events has significant temporal and spatial variations. The mean rainfall intensity (I), the impervious rate (IMR) and max 5-min intensity (Imax5) are the critical parameters of EMCs, while Imax5, antecedent dry days (ADD) and rainfall depth (RD) are the critical parameters of FF40. Intercepting the first 40% of runoff volume can remove 55% of TSS load, 53% of COD load, 58% of TN load, and 61% of TP load, respectively, according to all the storm events. These results may be helpful in mitigating stormwater runoff pollution for many other urban areas in developing countries. PMID:25774922

  4. Stormwater runoff pollutant loading distributions and their correlation with rainfall and catchment characteristics in a rapidly industrialized city.

    Science.gov (United States)

    Li, Dongya; Wan, Jinquan; Ma, Yongwen; Wang, Yan; Huang, Mingzhi; Chen, Yangmei

    2015-01-01

    Fast urbanization and industrialization in developing countries result in significant stormwater runoff pollution, due to drastic changes in land-use, from rural to urban. A three-year study on the stormwater runoff pollutant loading distributions of industrial, parking lot and mixed commercial and residential catchments was conducted in the Tongsha reservoir watershed of Dongguan city, a typical, rapidly industrialized urban area in China. This study presents the changes in concentration during rainfall events, event mean concentrations (EMCs) and event pollution loads per unit area (EPLs). The first flush criterion, namely the mass first flush ratio (MFFn), was used to identify the first flush effects. The impacts of rainfall and catchment characterization on EMCs and pollutant loads percentage transported by the first 40% of runoff volume (FF40) were evaluated. The results indicated that the pollutant wash-off process of runoff during the rainfall events has significant temporal and spatial variations. The mean rainfall intensity (I), the impervious rate (IMR) and max 5-min intensity (Imax5) are the critical parameters of EMCs, while Imax5, antecedent dry days (ADD) and rainfall depth (RD) are the critical parameters of FF40. Intercepting the first 40% of runoff volume can remove 55% of TSS load, 53% of COD load, 58% of TN load, and 61% of TP load, respectively, according to all the storm events. These results may be helpful in mitigating stormwater runoff pollution for many other urban areas in developing countries.

  5. Evaluation of Pollutant Loads: Organic and Inorganic in River ...

    African Journals Online (AJOL)

    This study was carried out to determine the organic and inorganic pollutant loads in River Ukoghor of the Lower Benue Basin. Grab water samples were collected from the outlet of the River into River Benue, twice a month in three replications for a period of eight months (April November, 2002) using sterilized one-litre ...

  6. Children's Urinary Environmental Carbon Load. A Novel Marker Reflecting Residential Ambient Air Pollution Exposure?

    Science.gov (United States)

    Saenen, Nelly D; Bové, Hannelore; Steuwe, Christian; Roeffaers, Maarten B J; Provost, Eline B; Lefebvre, Wouter; Vanpoucke, Charlotte; Ameloot, Marcel; Nawrot, Tim S

    2017-10-01

    Ambient air pollution, including black carbon, entails a serious public health risk because of its carcinogenic potential and as climate pollutant. To date, an internal exposure marker for black carbon particles that have cleared from the systemic circulation into the urine does not exist. To develop and validate a novel method to measure black carbon particles in a label-free way in urine. We detected urinary carbon load in 289 children (aged 9-12 yr) using white-light generation under femtosecond pulsed laser illumination. Children's residential black carbon concentrations were estimated based on a high-resolution spatial temporal interpolation method. We were able to detect urinary black carbon in all children, with an overall average (SD) of 98.2 × 10 5 (29.8 × 10 5 ) particles/ml. The urinary black carbon load was positively associated with medium-term to chronic (1 mo or more) residential black carbon exposure: +5.33 × 10 5 particles/ml higher carbon load (95% confidence interval, 1.56 × 10 5 to 9.10 × 10 5 particles/ml) for an interquartile range increment in annual residential black carbon exposure. Consistently, children who lived closer to a major road (≤160 m) had higher urinary black carbon load (6.93 × 10 5 particles/ml; 95% confidence interval, 0.77 × 10 5 to 13.1 × 10 5 ). Urinary black carbon mirrors the accumulation of medium-term to chronic exposure to combustion-related air pollution. This specific biomarker reflects internal systemic black carbon particles cleared from the circulation into the urine, allowing investigators to unravel the complexity of particulate-related health effects.

  7. Low-cost removal of organic pollutants with nickel nanoparticle loaded ordered macroporous hydrogel as high performance catalyst

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Mingyi, E-mail: tmyi@tjcu.edu.cn [Department of Applied Chemistry, School of Science, Tianjin University of Commerce, Tianjin 300134 (China); Huang, Guanbo, E-mail: gbhuang2007@hotmail.com [Department of Chemistry, School of Science, Tianjin University, Tianjin 300072 (China); Zhang, Sai [Department of Applied Chemistry, School of Science, Tianjin University of Commerce, Tianjin 300134 (China); Liu, Yue [Department of Chemistry, School of Science, Tianjin University, Tianjin 300072 (China); Li, Xianxian [Department of Applied Chemistry, School of Science, Tianjin University of Commerce, Tianjin 300134 (China); Wang, Xingrui [Department of Chemistry, School of Science, Tianjin University, Tianjin 300072 (China); Pang, Xiaobo [Department of Applied Chemistry, School of Science, Tianjin University of Commerce, Tianjin 300134 (China); Qiu, Haixia, E-mail: qhx@tju.edu.cn [Department of Chemistry, School of Science, Tianjin University, Tianjin 300072 (China)

    2014-06-01

    A facile route for the in situ preparation of catalytically active Ni nanoparticles (NPs) in ordered macroporous hydrogel (OMH) has been developed. The hydrogel was fabricated based on polystyrene colloid template. The electronegativity of amide and carboxyl groups on the poly(acrylamide-co-acryl acid) chains of the hydrogel caused strong binding of Ni{sup 2+} ions which made them distribute uniformly inside the hydrogel. When immersed in NaBH{sub 4} aqueous solution, the Ni{sup 2+} ions on the hydrogel were reduced to Ni NPs. The resultant Ni NPs loaded OMH showed good catalytic activity for the reduction of a common organic pollutant, 4-nitrophenol, with NaBH{sub 4}. A kinetic study of the catalytic reaction was carried out. The rate constant per unit weight could reach 0.53 s{sup −1} g{sup −1}, which is much better than many common hydrogel loaded nickel catalysts. Moreover, the current catalyst can be easily separated and recovered with stable catalytic activity. - Highlights: • A new poly(acrylamide-co-acryl acid) hydrogel with ordered macropores. • A simple in situ fabrication of nickel nanoparticles under mild conditions. • High-performance heterogeneous catalyst for removal of nitrophenol from water. • Good recyclability of catalyst without any complicated regeneration process.

  8. Low-cost removal of organic pollutants with nickel nanoparticle loaded ordered macroporous hydrogel as high performance catalyst

    International Nuclear Information System (INIS)

    Tang, Mingyi; Huang, Guanbo; Zhang, Sai; Liu, Yue; Li, Xianxian; Wang, Xingrui; Pang, Xiaobo; Qiu, Haixia

    2014-01-01

    A facile route for the in situ preparation of catalytically active Ni nanoparticles (NPs) in ordered macroporous hydrogel (OMH) has been developed. The hydrogel was fabricated based on polystyrene colloid template. The electronegativity of amide and carboxyl groups on the poly(acrylamide-co-acryl acid) chains of the hydrogel caused strong binding of Ni 2+ ions which made them distribute uniformly inside the hydrogel. When immersed in NaBH 4 aqueous solution, the Ni 2+ ions on the hydrogel were reduced to Ni NPs. The resultant Ni NPs loaded OMH showed good catalytic activity for the reduction of a common organic pollutant, 4-nitrophenol, with NaBH 4 . A kinetic study of the catalytic reaction was carried out. The rate constant per unit weight could reach 0.53 s −1  g −1 , which is much better than many common hydrogel loaded nickel catalysts. Moreover, the current catalyst can be easily separated and recovered with stable catalytic activity. - Highlights: • A new poly(acrylamide-co-acryl acid) hydrogel with ordered macropores. • A simple in situ fabrication of nickel nanoparticles under mild conditions. • High-performance heterogeneous catalyst for removal of nitrophenol from water. • Good recyclability of catalyst without any complicated regeneration process

  9. FeOOH-loaded MnO2 nano-composite: An efficient emergency material for thallium pollution incident.

    Science.gov (United States)

    Chen, Meiqing; Wu, Pingxiao; Yu, Langfeng; Liu, Shuai; Ruan, Bo; Hu, Haihui; Zhu, Nengwu; Lin, Zhang

    2017-05-01

    A FeOOH-loaded MnO 2 nano-composite was developed as an emergency material for Tl(I) pollution incident. Structural characterizations showed that FeOOH successfully loaded onto MnO 2 , the nanosheet-flower structure and high surface area (191 m 2  g -1 ) of material contributed to the excellent performance for Tl(I) removal. FeOOH-loaded MnO 2 with a Fe/Mn molar ratio of 1:2 exhibited a noticeable enhanced capacity for Tl(I) removal compared to that of pure MnO 2 . The outstanding performance for Tl(I) removal involves in extremely high efficiency (achieved equilibrium and drinking water standard within 4 min) and the large maximum adsorption capacity (450 mg g -1 ). Both the control-experiment and XPS characterization proved that the removal mechanism of Tl(I) on FeOOH-loaded MnO 2 included adsorption and oxidation: the oxidation of MnO 2 played an important role for Tl(I) removal, and the adsorption of FeOOH loaded on MnO 2 enhanced Tl(I) purification at the same time. In-depth purification of Tl(I) had reach drinking water standards (0.1 μg L -1 ) at pH above 7, and there wasn't security risk produced from the dissolution of Mn 2+ and Fe 2+ . Moreover, the as-prepared material could be utilized as a recyclable adsorbent regenerated by using NaOH-NaClO binary solution. Therefore, the synthesized FeOOH-loaded MnO 2 in this study has the potential to be applied as an emergency material for thallium pollution incident. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Modeling of land use and reservoir effects on nonpoint source pollution in a highly agricultural basin

    Science.gov (United States)

    Wu, Yiping; Liu, Shu-Guang

    2012-01-01

    Nonpoint source (NPS) pollution is tightly linked to land use activities that determine the sources and magnitudes of pollutant loadings to stream water. The pollutant loads may also be alleviated within reservoirs because of the physical interception resulting from changed hydrological regimes and other biochemical processes. It is important but challenging to assess the NPS pollution processes with human effects due to the measurement limitations. The objective of this study is to evaluate the effects of human activities such as land uses and reservoir operation on the hydrological and NPS pollution processes in a highly agricultural area-the Iowa River Basin-using the Soil and Water Assessment Tool (SWAT). The evaluation of model performance at multiple sites reveals that SWAT can consistently simulate the daily streamflow, and monthly/annual sediment and nutrient loads (nitrate nitrogen and mineral phosphorus) in the basin. We also used the calibrated model to estimate the trap efficiencies of sediment (~78%) and nutrients (~30%) in the Coralville Reservoir within the basin. These non-negligible effects emphasize the significance of incorporating the sediment and nutrient removal mechanisms into watershed system studies. The spatial quantification of the critical NPS pollution loads can help identify hot-spot areas that are likely locations for the best management practices.

  11. Air pollution and impact on eco-systems. Load concept/critical level and its consequences

    International Nuclear Information System (INIS)

    Elichegaray, C.

    1993-01-01

    Critical loads and critical levels respectively can be defined as the deposition value, or the concentration of pollutants in the atmosphere, above which adverse effects on receptors such as plants, ecosystems, materials may occur. Important research is currently being developed on critical loads and levels in the framework of the Geneva convention on transboundary air pollution. Several binding protocols have been elaborated between the european countries, the Canada, and the USA, to reduce their emissions of sulphur, nitrogen oxides, volatile organic compounds. This article describes the critical loads and levels approach, and the way by which this concept is now used for the revision of the sulphur protocol. (author). 6 refs., 5 figs., 4 tabs

  12. [Estimation of urban non-point source pollution loading and its factor analysis in the Pearl River Delta].

    Science.gov (United States)

    Liao, Yi-Shan; Zhuo, Mu-Ning; Li, Ding-Qiang; Guo, Tai-Long

    2013-08-01

    In the Pearl Delta region, urban rivers have been seriously polluted, and the input of non-point source pollution materials, such as chemical oxygen demand (COD), into rivers cannot be neglected. During 2009-2010, the water qualities at eight different catchments in the Fenjiang River of Foshan city were monitored, and the COD loads for eight rivulet sewages were calculated in respect of different rainfall conditions. Interesting results were concluded in our paper. The rainfall and landuse type played important roles in the COD loading, with greater influence of rainfall than landuse type. Consequently, a COD loading formula was constructed that was defined as a function of runoff and landuse type that were derived SCS model and land use map. Loading of COD could be evaluated and predicted with the constructed formula. The mean simulation accuracy for single rainfall event was 75.51%. Long-term simulation accuracy was better than that of single rainfall. In 2009, the estimated COD loading and its loading intensity were 8 053 t and 339 kg x (hm2 x a)(-1), and the industrial land was regarded as the main source of COD pollution area. The severe non-point source pollution such as COD in Fenjiang River must be paid more attention in the future.

  13. Pollutant loads and water quality in streams of heavily populated and industrialised towns

    Science.gov (United States)

    Ntengwe, F. W.

    The availability of portable water is often taken for granted and water allowed to get polluted. Industries, settlements, farms, markets, leaking sewer lines, poor hygiene practices are all potential sources of pollution. Each pollutant has its own effect on water and the environment. A study was conducted in Kitwe Stream in order to establish whether engineering and other human activities affect water quality. Samples were collected at ten points, the first point being at the source while the tenth point was at the confluence with the Kafue River. The samples were analysed for physical, chemical and biological parameters. The results revealed high levels of concentration and loads of total suspended solids (TSS). The points with high TSS values were P4 (118 mg/l) and P6 (140 mg/l) representing daily loads of 7.74 and 8.71 tonnes, respectively. The highest values of coliform were found at points P9 (2099), P10 (2558) followed by P4 (1149), P5 (1256) and P6 (1370). High values of nitrites were found at points P4 (34 mg/l), P5 (32 mg/l), P6 (21 mg/l) and P10 (12.4 mg/l). Chlorides were also found to be high at points P4, P5 and P6 with values of 70 mg/l, 80 mg/l and 87 mg/l, respectively. These parameters exceeded the maximum contaminant level (MCL) of 100 mg/l for TSS, 1 mg/l for nitrites, 500/100 ml for coliform in Zambia. The conductivity and coliform were also found to be high (>500 μS/cm, >500). The benthic study revealed a normal diversity of invertebrates but chironomidae was found to be on average 60% of total species counted. The fish activity was high upstream and low downstream at the mouth of the stream where it joins the Kafue River. There was no fish activity at the middle points. The planktons (phytoplankton and zooplankton) count revealed a high count (15-30 per ml) in places where there was high fish activity and a low count (1-5 per ml) where there was no activity. The stream water quality was therefore affected by the human activities.

  14. The target programme for water pollution control up to year 2005. The impact to alternative pollution load levels on inland waterways; Vesiensuojelun tavoitteet vuoteen 2005. Vaihtoehtoisten kuormitustasojen vaikutukset sisaevesissae

    Energy Technology Data Exchange (ETDEWEB)

    Marttunen, M. [eds.

    1998-11-01

    The publication presents waterway-specific pollution loading surveys connected with the target programme for water pollution control up to 2005 and the results of a survey concerning inland waters. The work evaluates and compares the magnitude and significance of future pollution loads from various sources on the state of the waterway and assesses the impact on the condition of the waterway of two alternative pollution loading levels. The survey was conducted on 24 lakes or parts thereof and 10 rivers. Sixteen of these are subject to loading from the pulls and paper industry. The waterways selected for examination were especially ones for which relatively recent loading analyses were available and to which water quality models have been applied. The general classification of fitness for use was used as a benchmark for changes occurring in the water quality of the waterways. The findings show that particularly the large waterway systems can be moved into a higher fitness for use class by reducing substantially the nutrient loading. Significant improvement in the condition of eutrophic lakes and coastal rivers with their internal loads is difficult. (orig.) 26 refs.

  15. Global Anthropogenic Phosphorus Loads to Fresh Water, Grey Water Footprint and Water Pollution Levels: A High-Resolution Global Study

    Science.gov (United States)

    Mekonnen, M. M.; Hoekstra, A. Y. Y.

    2014-12-01

    We estimated anthropogenic phosphorus (P) loads to freshwater, globally at a spatial resolution level of 5 by 5 arc minute. The global anthropogenic P load to freshwater systems from both diffuse and point sources in the period 2002-2010 was 1.5 million tonnes per year. China contributed about 30% to this global anthropogenic P load. India was the second largest contributor (8%), followed by the USA (7%), Spain and Brazil each contributing 6% to the total. The domestic sector contributed the largest share (54%) to this total followed by agriculture (38%) and industry (8%). Among the crops, production of cereals had the largest contribution to the P loads (32%), followed by fruits, vegetables, and oil crops, each contributing about 15% to the total. We also calculated the resultant grey water footprints, and relate the grey water footprints per river basin to runoff to calculate the P-related water pollution level (WPL) per catchment.

  16. Fifth Baltic Sea pollution load compilation (PLC-5)

    Energy Technology Data Exchange (ETDEWEB)

    Knuuttila, S.; Svendsen, L. M.; Staaf, H.; Kotilainen, P.; Boutrup, S.; Pyhala, M.; Durkin, M.

    2011-07-01

    This report includes the main results from the Fifth Pollution Load Compilation abbreviated PLC-5. It includes quantified annual waterborne total loads (from rivers, unmonitored and coastal areas as well as direct point and diffuse sources discharging directly to the Baltic Sea) from 1994 to 2008 to provide a basis for evaluating any decreasing (or increasing) trends in the total waterborne inputs to the Baltic Sea. Chapter 1 contains the objectives of PLC and the framework on classification of inputs and sources. Chapter 2 includes a short description of the Baltic Sea catchment area, while the methods for quantification and analysis together with quality assurance topics are briefly introduced in Chapter 3. More detailed information on methodologies is presented in the PLC-5 guidelines (HELCOM 2006). Chapter 4 reports the total inputs to the Baltic Sea of nutrients and selected heavy metals. Furthermore, the results of the quatification of discharges and losses of nitrogen and phosphorus from point and diffuse sources into inland surface waters within the Baltic Sea catchment area (source-oriented approach or gross loads) as well as the total load to the maritime area (load-oriented approarch or net loads) in 2006 are shown. Typically, results are presented by country and by main Baltic Sea sub-region. In Chapter 5, flow normalization is introduced and the results of trend analyses on 1994-2008 time series data on total waterborne loads of nitrogen and phosphorus are given together with a first evaluation of progress in obtaining the provisional reduction targets by country and by main Baltic Sea sub-region. Chapter 6 includes discussion of some of the main conclusions and advice for future PLCs. The annexes contain the flow-normalized annual load data and figures and tables with results from the PLC-5.

  17. Simulation and evaluation of pollution load reduction scenarios for water environmental management: a case study of inflow river of Taihu Lake, China.

    Science.gov (United States)

    Zhang, Ruibin; Qian, Xin; Zhu, Wenting; Gao, Hailong; Hu, Wei; Wang, Jinhua

    2014-09-09

    In the beginning of the 21st century, the deterioration of water quality in Taihu Lake, China, has caused widespread concern. The primary source of pollution in Taihu Lake is river inflows. Effective pollution load reduction scenarios need to be implemented in these rivers in order to improve the water quality of Taihu Lake. It is important to select appropriate pollution load reduction scenarios for achieving particular goals. The aim of this study was to facilitate the selection of appropriate scenarios. The QUAL2K model for river water quality was used to simulate the effects of a range of pollution load reduction scenarios in the Wujin River, which is one of the major inflow rivers of Taihu Lake. The model was calibrated for the year 2010 and validated for the year 2011. Various pollution load reduction scenarios were assessed using an analytic hierarchy process, and increasing rates of evaluation indicators were predicted using the Delphi method. The results showed that control of pollution from the source is the optimal method for pollution prevention and control, and the method of "Treatment after Pollution" has bad environmental, social and ecological effects. The method applied in this study can assist for environmental managers to select suitable pollution load reduction scenarios for achieving various objectives.

  18. Shift of the circumstances in effluent pollutant loads and water pollution in the Seto Inland Sea; Setonaikai ni okeru odaku fukaryo to suishitsu no hensen

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, T. [Hiroshima Prefectural Institute of Public Health and Environment, Hiroshima (Japan); Komai, Y. [Hyogo Prefectural Institute of Environmental Science, Kobe (Japan); Koyama, T. [Wakayama Prefectural Research Center of Environment and Public Health, Wakayama (Japan); Nagafuchi, O. [Fukuoka Institute of Health and Environment Science, Fukuoka (Japan); Hino, Y. [Kagawa Prefecture Environmental Research Center, Kagawa (Japan); Murakami, K. [Okayama Prefectural Institute for Environmental and Public Health, Okayama (Japan)

    1998-11-10

    The relationship between the shift of the amount of effluent pollutant loads and the quality of water in and after the 1970s is studied for the verification of the effect of wastewater control and pollution measures for the Seto Inland Sea. The pollution loads are analyzed using the population, sewerage system diffusion rate, industrial production amount, number of farm animals, etc., gathered from existing data, and the quality of water is analyzed using the surface layer data collected at 124 sites. Although population as the source of pollutant loads has enlarged, the enlargement does not bring about a significant change in the loads, this partly due to the diffusion of sewerage systems. The rates of reduction in the 1979-1994 period of COD (chemical oxygen demand), T-N (total nitrogen), and T-P (total phosphorus) are 25.2%, 5.3%, and 30.3%, respectively. COD has returned to the previous level, but transparency has turned poorer. T-N and T-P worsened in the 1985-1989 period, and have not yet returned to the levels of 1980-1984. Pollution is in progress in Osaka Bay, Hiroshima Bay, and some others. In some sea areas, transparency is improving, with COD and Chl.a on the increase. From the nutrient salt and Chl.a scatter diagrams, the potential of algal growth relative to the concentration of nutrient salts may be estimated. Organic pollution is affected by algal growth. The organic matters produced in the inland sea are approximately 20 times as much as the organic matters produced on land. 18 refs., 11 figs., 2 tabs.

  19. Assessment of annual pollutant loads in combined sewers from continuous turbidity measurements: sensitivity to calibration data.

    Science.gov (United States)

    Lacour, C; Joannis, C; Chebbo, G

    2009-05-01

    This article presents a methodology for assessing annual wet weather Suspended Solids (SS) and Chemical Oxygen Demand (COD) loads in combined sewers, along with the associated uncertainties from continuous turbidity measurements. The proposed method is applied to data from various urban catchments in the cities of Paris and Nantes. The focus here concerns the impact of the number of rain events sampled for calibration (i.e. through establishing linear SS/turbidity or COD/turbidity relationships) on the uncertainty of annual pollutant load assessments. Two calculation methods are investigated, both of which rely on Monte Carlo simulations: random assignment of event-specific calibration relationships to each individual rain event, and the use of an overall relationship built from the entire available data set. Since results indicate a fairly low inter-event variability for calibration relationship parameters, an accurate assessment of pollutant loads can be derived, even when fewer than 10 events are sampled for calibration purposes. For operational applications, these results suggest that turbidity could provide a more precise evaluation of pollutant loads at lower cost than typical sampling methods.

  20. Impacts of climate change on TN load and its control in a River Basin with complex pollution sources.

    Science.gov (United States)

    Yang, Xiaoying; Warren, Rachel; He, Yi; Ye, Jinyin; Li, Qiaoling; Wang, Guoqing

    2018-02-15

    It is increasingly recognized that climate change could affect the quality of water through complex natural and anthropogenic mechanisms. Previous studies on climate change and water quality have mostly focused on assessing its impact on pollutant loads from agricultural runoff. A sub-daily SWAT model was developed to simulate the discharge, transport, and transformation of nitrogen from all known anthropogenic sources including industries, municipal sewage treatment plants, concentrated and scattered feedlot operations, rural households, and crop production in the Upper Huai River Basin. This is a highly polluted basin with total nitrogen (TN) concentrations frequently exceeding Class V of the Chinese Surface Water Quality Standard (GB3838-2002). Climate change projections produced by 16 Global Circulation Models (GCMs) under the RCP 4.5 and RCP 8.5 scenarios in the mid (2040-2060) and late (2070-2090) century were used to drive the SWAT model to evaluate the impacts of climate change on both the TN loads and the effectiveness of three water pollution control measures (reducing fertilizer use, constructing vegetative filter strips, and improving septic tank performance) in the basin. SWAT simulation results have indicated that climate change is likely to cause an increase in both monthly average and extreme TN loads in February, May, and November. The projected impact of climate change on TN loads in August is more varied between GCMs. In addition, climate change is projected to have a negative impact on the effectiveness of septic tanks in reducing TN loads, while its impacts on the other two measures are more uncertain. Despite the uncertainty, reducing fertilizer use remains the most effective measure for reducing TN loads under different climate change scenarios. Meanwhile, improving septic tank performance is relatively more effective in reducing annual TN loads, while constructing vegetative filter strips is more effective in reducing annual maximum monthly

  1. Simulation and Evaluation of Pollution Load Reduction Scenarios for Water Environmental Management: A Case Study of Inflow River of Taihu Lake, China

    Science.gov (United States)

    Zhang, Ruibin; Qian, Xin; Zhu, Wenting; Gao, Hailong; Hu, Wei; Wang, Jinhua

    2014-01-01

    In the beginning of the 21st century, the deterioration of water quality in Taihu Lake, China, has caused widespread concern. The primary source of pollution in Taihu Lake is river inflows. Effective pollution load reduction scenarios need to be implemented in these rivers in order to improve the water quality of Taihu Lake. It is important to select appropriate pollution load reduction scenarios for achieving particular goals. The aim of this study was to facilitate the selection of appropriate scenarios. The QUAL2K model for river water quality was used to simulate the effects of a range of pollution load reduction scenarios in the Wujin River, which is one of the major inflow rivers of Taihu Lake. The model was calibrated for the year 2010 and validated for the year 2011. Various pollution load reduction scenarios were assessed using an analytic hierarchy process, and increasing rates of evaluation indicators were predicted using the Delphi method. The results showed that control of pollution from the source is the optimal method for pollution prevention and control, and the method of “Treatment after Pollution” has bad environmental, social and ecological effects. The method applied in this study can assist for environmental managers to select suitable pollution load reduction scenarios for achieving various objectives. PMID:25207492

  2. Economic total maximum daily load for watershed-based pollutant trading.

    Science.gov (United States)

    Zaidi, A Z; deMonsabert, S M

    2015-04-01

    Water quality trading (WQT) is supported by the US Environmental Protection Agency (USEPA) under the framework of its total maximum daily load (TMDL) program. An innovative approach is presented in this paper that proposes post-TMDL trade by calculating pollutant rights for each pollutant source within a watershed. Several water quality trading programs are currently operating in the USA with an objective to achieve overall pollutant reduction impacts that are equivalent or better than TMDL scenarios. These programs use trading ratios for establishing water quality equivalence among pollutant reductions. The inbuilt uncertainty in modeling the effects of pollutants in a watershed from both the point and nonpoint sources on receiving waterbodies makes WQT very difficult. A higher trading ratio carries with it increased mitigation costs, but cannot ensure the attainment of the required water quality with certainty. The selection of an applicable trading ratio, therefore, is not a simple process. The proposed approach uses an Economic TMDL optimization model that determines an economic pollutant reduction scenario that can be compared with actual TMDL allocations to calculate selling/purchasing rights for each contributing source. The methodology is presented using the established TMDLs for the bacteria (fecal coliform) impaired Muddy Creek subwatershed WAR1 in Rockingham County, Virginia, USA. Case study results show that an environmentally and economically superior trading scenario can be realized by using Economic TMDL model or any similar model that considers the cost of TMDL allocations.

  3. Source Apportionment of Annual Water Pollution Loads in River Basins by Remote-Sensed Land Cover Classification

    Directory of Open Access Journals (Sweden)

    Yi Wang

    2016-08-01

    Full Text Available In this study, in order to determine the efficiency of estimating annual water pollution loads from remote-sensed land cover classification and ground-observed hydrological data, an empirical model was investigated. Remote sensing data imagery from National Oceanic and Atmospheric Administration (NOAA Advanced Very High Resolution Radiometer were applied to an 11 year (1994–2004 water quality dataset for 30 different rivers in Japan. Six water quality indicators—total nitrogen (TN, total phosphorus (TP, biochemical oxygen demand (BOD, chemical oxygen demand (COD, and dissolved oxygen (DO—were examined by using the observed river water quality data and generated land cover map. The TN, TP, BOD, COD, and DO loads were estimated for the 30 river basins using the empirical model. Calibration (1994–1999 and validation (2000–2004 results showed that the proposed simulation technique was useful for predicting water pollution loads in the river basins. We found that vegetation land cover had a larger impact on TP export into all rivers. Urban areas had a very small impact on DO export into rivers, but a relatively large impact on BOD and TN export. The results indicate that the application of land cover data generated from the remote-sensed imagery could give a useful interpretation about the river water quality.

  4. Simulation and Evaluation of Pollution Load Reduction Scenarios for Water Environmental Management: A Case Study of Inflow River of Taihu Lake, China

    Directory of Open Access Journals (Sweden)

    Ruibin Zhang

    2014-09-01

    Full Text Available In the beginning of the 21st century, the deterioration of water quality in Taihu Lake, China, has caused widespread concern. The primary source of pollution in Taihu Lake is river inflows. Effective pollution load reduction scenarios need to be implemented in these rivers in order to improve the water quality of Taihu Lake. It is important to select appropriate pollution load reduction scenarios for achieving particular goals. The aim of this study was to facilitate the selection of appropriate scenarios. The QUAL2K model for river water quality was used to simulate the effects of a range of pollution load reduction scenarios in the Wujin River, which is one of the major inflow rivers of Taihu Lake. The model was calibrated for the year 2010 and validated for the year 2011. Various pollution load reduction scenarios were assessed using an analytic hierarchy process, and increasing rates of evaluation indicators were predicted using the Delphi method. The results showed that control of pollution from the source is the optimal method for pollution prevention and control, and the method of “Treatment after Pollution” has bad environmental, social and ecological effects. The method applied in this study can assist for environmental managers to select suitable pollution load reduction scenarios for achieving various objectives.

  5. Acid mine drainage in the Iberian Pyrite Belt: 1. Hydrochemical characteristics and pollutant load of the Tinto and Odiel rivers.

    Science.gov (United States)

    Nieto, Jose M; Sarmiento, Aguasanta M; Canovas, Carlos R; Olias, Manuel; Ayora, Carlos

    2013-11-01

    Acid mine drainage in the Iberian Pyrite Belt is probably the worst case in the world of surface water pollution associated with mining of sulphide mineral deposits. The Iberian Pyrite Belt is located in SW Iberian Peninsula, and it has been mined during the last 4,500 years. The central and eastern part of the Iberian Pyrite Belt is drained by the Tinto and Odiel rivers, which receive most of the acidic leachates from the mining areas. As a result, the main channels of the Tinto and Odiel rivers are very rich in metals and highly acidic until reaching the Atlantic Ocean. A significant amount of the pollutant load transported by these two rivers is delivered during the rainy season, as is usual in rivers of Mediterranean climate regions. Therefore, in order to have an accurate estimation of the pollutant loads transported by the Tinto and Odiel rivers, a systematic sampling on a weekly basis and a high temporal resolution sampling of floods events were both performed. Results obtained show that metal fluxes are strongly dependent on the study period, highlighting the importance of inter-annual studies involving dry and wet years.

  6. Estimation of transported pollutant load in Ardila catchment using the SWAT model

    OpenAIRE

    DURÃO, A.; LEITÃO, P.; BRITO, D.; FERNANDES, R.M.; NEVES, R.; MORAIS, M.

    2011-01-01

    Excess of organic matter and nutrients in the water body promotes algae blooms, which can accelerate the eutrophication process, situation often observed in the Ardila river. This river was identified as very polluted and classified as critical for Alqueva-Pedrogão System. The aim of this study was to estimate the transported nutrients load in a transboundary catchment using the SWAT (Soil and Water Assessment Tool) model and to determine the contribution off nutrients load in the entire catc...

  7. Changes in pollution load and environmental trends in the North Sea

    Energy Technology Data Exchange (ETDEWEB)

    Pawlak, Janet

    1998-12-01

    This publication relates to the quality of the marine environment in the North Sea. Changes in pollution load and environmental trends are analysed. Main themes discussed cover chemical contaminants, temporal trends contaminants in biota, inputs of contaminants to the marine environment, and biological effects of contaminants and biological monitoring. 14 refs., 5 figs., 4 tabs.

  8. An early warning system for groundwater pollution based on the assessment of groundwater pollution risks.

    Science.gov (United States)

    Zhang, Weihong.; Zhao, Yongsheng; Hong, Mei; Guo, Xiaodong

    2009-04-01

    Groundwater pollution usually is complex and concealed, remediation of which is difficult, high cost, time-consuming, and ineffective. An early warning system for groundwater pollution is needed that detects groundwater quality problems and gets the information necessary to make sound decisions before massive groundwater quality degradation occurs. Groundwater pollution early warning were performed by considering comprehensively the current groundwater quality, groundwater quality varying trend and groundwater pollution risk . The map of the basic quality of the groundwater was obtained by fuzzy comprehensive evaluation or BP neural network evaluation. Based on multi-annual groundwater monitoring datasets, Water quality state in sometime of the future was forecasted using time-sequenced analyzing methods. Water quality varying trend was analyzed by Spearman's rank correlative coefficient.The relative risk map of groundwater pollution was estimated through a procedure that identifies, cell by cell,the values of three factors, that is inherent vulnerability, load risk of pollution source and contamination hazard. DRASTIC method was used to assess inherent vulnerability of aquifer. Load risk of pollution source was analyzed based on the potential of contamination and pollution degree. Assessment index of load risk of pollution source which involves the variety of pollution source, quantity of contaminants, releasing potential of pollutants, and distance were determined. The load risks of all sources considered by GIS overlay technology. Early warning model of groundwater pollution combined with ComGIS technology organically, the regional groundwater pollution early-warning information system was developed, and applied it into Qiqiha'er groundwater early warning. It can be used to evaluate current water quality, to forecast water quality changing trend, and to analyze space-time influencing range of groundwater quality by natural process and human activities. Keywords

  9. Global Anthropogenic Phosphorus Loads to Freshwater and Associated Grey Water Footprints and Water Pollution Levels: A High-Resolution Global Study

    Science.gov (United States)

    Mekonnen, Mesfin M.; Hoekstra, Arjen Y.

    2018-01-01

    We estimate the global anthropogenic phosphorus (P) loads to freshwater and the associated grey water footprints (GWFs) for the period 2002-2010, at a spatial resolution of 5 × 5 arc min, and compare the GWF per river basin to runoff to assess the P-related water pollution level (WPL). The global anthropogenic P load to freshwater systems from both diffuse and point sources is estimated at 1.5 Tg/yr. More than half of this total load was in Asia, followed by Europe (19%) and Latin America and the Caribbean (13%). The domestic sector contributed 54% to the total, agriculture 38%, and industry 8%. In agriculture, cereals production had the largest contribution to the P load (31%), followed by fruits, vegetables, and oil crops, each contributing 15%. The global total GWF related to anthropogenic P loads is estimated to be 147 × 1012 m3/yr, with China contributing 30%, India 8%, USA 7%, and Spain and Brazil 6% each. The basins with WPL > 1 (where GWF exceeds the basin's assimilation capacity) together cover about 38% of the global land area, 37% of the global river discharge, and provide residence to about 90% of the global population.

  10. Removal of Organic Pollutants from Municipal Wastewater by Applying High-Rate Algal Pond in Addis Ababa, Ethiopia

    Science.gov (United States)

    Alemu, Keneni; Assefa, Berhanu; Kifle, Demeke; Kloos, Helmut

    2018-05-01

    The discharge of inadequately treated municipal wastewater has aggravated the pollution load in developing countries including Ethiopia. Conventional wastewater treatment methods that require high capital and operational costs are not affordable for many developing nations, including Ethiopia. This study aimed to investigate the performance of two high-rate algal ponds (HRAPs) in organic pollutant removal from primary settled municipal wastewater under highland tropical climate conditions in Addis Ababa. The experiment was done for 2 months at hydraulic retention times (HRTs) ranging from 2 to 8 days using an organic loading rates ranging 333-65 kg {BOD}5 /ha/day using two HRAPs, 250 and 300 mm deep, respectively. In this experiment, Chlorella sp., Chlamydomonas sp., and Scenedesmus sp., the class of Chlorophyceae, were identified as the dominant species. Chlorophyll-a production was higher in the shallower ponds (250 mm) throughout the course of the study, whereas the deeper HRAP (300 mm) showed better dissolved oxygen production. The maximum COD and {BOD}5 removal of 78.03 and 81.8% was achieved at a 6-day HRT operation in the 250-mm-deep HRAP. Therefore, the 300-mm-deep HRAP is promising for scaling up organic pollutant removal from municipal wastewater at a daily average organic loading rate of 109.3 kg {BOD}5 /ha/day and a 6-day HRT. We conclude that the removal of organic pollutants in HRAP can be controlled by pond depth, organic loading rate, and HRT.

  11. Embodied pollution in trade: Estimating the "environmental load displacement" of the industrial countries

    OpenAIRE

    Muradian, Roldan; O'Connor, Martin; Martinez-Alier, Joan

    2001-01-01

    The present paper sets out to aid in the development of "environmental load displacement" indicators. Developing the notion of the "environmental memory" of physical flows, we estimated embodied pollution in trade of 18 industrialized countries with a) the rest of the world and b) developing countries, from 1976 to 1994. We found that in the last years of analysis, total imports of Japan, USA and Western Europe have entailed, in general, larger air pollutant emissions than local exports. The ...

  12. Total maximum allocated load calculation of nitrogen pollutants by linking a 3D biogeochemical-hydrodynamic model with a programming model in Bohai Sea

    Science.gov (United States)

    Dai, Aiquan; Li, Keqiang; Ding, Dongsheng; Li, Yan; Liang, Shengkang; Li, Yanbin; Su, Ying; Wang, Xiulin

    2015-12-01

    The equal percent removal (EPR) method, in which pollutant reduction ratio was set as the same in all administrative regions, failed to satisfy the requirement for water quality improvement in the Bohai Sea. Such requirement was imposed by the developed Coastal Pollution Total Load Control Management. The total maximum allocated load (TMAL) of nitrogen pollutants in the sea-sink source regions (SSRs) around the Bohai Rim, which is the maximum pollutant load of every outlet under the limitation of water quality criteria, was estimated by optimization-simulation method (OSM) combined with loop approximation calculation. In OSM, water quality is simulated using a water quality model and pollutant load is calculated with a programming model. The effect of changes in pollutant loads on TMAL was discussed. Results showed that the TMAL of nitrogen pollutants in 34 SSRs was 1.49×105 ton/year. The highest TMAL was observed in summer, whereas the lowest in winter. TMAL was also higher in the Bohai Strait and central Bohai Sea and lower in the inner area of the Liaodong Bay, Bohai Bay and Laizhou Bay. In loop approximation calculation, the TMAL obtained was considered satisfactory for water quality criteria as fluctuation of concentration response matrix with pollutant loads was eliminated. Results of numerical experiment further showed that water quality improved faster and were more evident under TMAL input than that when using the EPR method

  13. Integrated waste load allocation for river water pollution control under uncertainty: a case study of Tuojiang River, China.

    Science.gov (United States)

    Xu, Jiuping; Hou, Shuhua; Yao, Liming; Li, Chaozhi

    2017-07-01

    This paper presents a bi-level optimization waste load allocation programming model under a fuzzy random environment to assist integrated river pollution control. Taking account of the leader-follower decision-making in the water function zones framework, the proposed approach examines the decision making feedback relationships and conflict coordination between the river basin authority and the regional Environmental Protection Agency (EPA) based on the Stackelberg-Nash equilibrium strategy. In the pollution control system, the river basin authority, as the leader, allocates equitable emissions rights to different subareas, and the then subarea EPA, as the followers, reallocates the limited resources to various functional zones to minimize pollution costs. This research also considers the uncertainty in the water pollution management, and the uncertain input information is expressed as fuzzy random variables. The proposed methodological approach is then applied to Tuojiang River in China and the bi-level linear programming model solutions are achieved using the Karush-Kuhn-Tucker condition. Based on the waste load allocation scheme results and various scenario analyses and discussion, some operational policies are proposed to assist decision makers (DMs) cope with waste load allocation problem for integrated river pollution control for the overall benefits.

  14. Global gray water footprint and water pollution levels related to anthropogenic nitrogen loads to fresh water

    NARCIS (Netherlands)

    Mekonnen, Mesfin; Hoekstra, Arjen Ysbert

    2015-01-01

    This is the first global assessment of nitrogen-related water pollution in river basins with a specification of the pollution by economic sector, and by crop for the agricultural sector. At a spatial resolution of 5 by 5 arc minute, we estimate anthropogenic nitrogen (N) loads to freshwater,

  15. Activation of peroxymonosulfate by graphitic carbon nitride loaded on activated carbon for organic pollutants degradation

    International Nuclear Information System (INIS)

    Wei, Mingyu; Gao, Long; Li, Jun; Fang, Jia; Cai, Wenxuan; Li, Xiaoxia; Xu, Aihua

    2016-01-01

    Highlights: • Supported g-C_3N_4 on AC catalysts with different loadings were prepared. • The metal free catalysts exhibited high efficiency for dyes degradation with PMS. • The catalyst presented a long-term stability for multiple runs. • The C=O groups played a key role in the oxidation process. - Abstract: Graphitic carbon nitride supported on activated carbon (g-C_3N_4/AC) was prepared through an in situ thermal approach and used as a metal free catalyst for pollutants degradation in the presence of peroxymonosulfate (PMS) without light irradiation. It was found that g-C_3N_4 was highly dispersed on the surface of AC with the increase of surface area and the exposition of more edges and defects. The much easier oxidation of C species in g-C_3N_4 to C=O was also observed from XPS spectra. Acid Orange 7 (AO7) and other organic pollutants could be completely degraded by the g-C_3N_4/AC catalyst within 20 min with PMS, while g-C_3N_4+PMS and AC+PMS showed no significant activity for the reaction. The performance of the catalyst was significantly influenced by the amount of g-C_3N_4 loaded on AC; but was nearly not affected by the initial solution pH and reaction temperature. In addition, the catalysts presented good stability. A nonradical mechanism accompanied by radical generation (HO· and SO_4·"−) in AO7 oxidation was proposed in the system. The C=O groups play a key role in the process; while the exposure of more N-(C)_3 group can further increase its electron density and basicity. This study can contribute to the development of green materials for sustainable remediation of aqueous organic pollutants.

  16. Pollution load index for heavy metals in Mian-Ab plain soil, Khuzestan, Iran.

    Science.gov (United States)

    Jorfi, Sahand; Maleki, Rohangiz; Jaafarzadeh, Neemat; Ahmadi, Mehdi

    2017-12-01

    Soil pollution by heavy metals is a major concern in agricultural area. Potential impact of heavy metals in agricultural soil on human health by accumulating in food chain demonstrated elsewhere. In this regard Mian-Ab plain as a major agricultural site of Khuzestan province considered for Arsenic, cadmium and lead concentration as the main potential toxic pollutants in soil. 50 topsoil samples were collected and analyzed by inductively coupled plasma mass spectrometry (ICP-MS). Also Contamination level of selected heavy metals in Mian-Ab Plain, was assessed by single factor contaminant index (PI) and pollution load index (PLI). Results show mean concentration of arsenic, cadmium and lead were 2.52, 0.30 and 7.21 mg kg -1 . Base on PLI results 12 point (24%) of the studied area show moderately polluted and 38 point (76%) show unpolluted area.

  17. Pre- and post-fire pollutant loads in an urban fringe watershed in Southern California.

    Science.gov (United States)

    Burke, M P; Hogue, T S; Kinoshita, A M; Barco, J; Wessel, C; Stein, E D

    2013-12-01

    Post-fire runoff has the potential to be a large source of contaminants to downstream areas. However, the magnitude of this effect in urban fringe watersheds adjacent to large sources of airborne contaminants is not well documented. The current study investigates the impacts of wildfire on stormwater contaminant loading from the upper Arroyo Seco watershed, burned in 2009. This watershed is adjacent to the Greater Los Angeles, CA, USA area and has not burned in over 60 years. Consequently, it acts as a sink for regional urban pollutants and presents an opportunity to study the impacts of wildfire. Pre- and post-fire storm samples were collected and analyzed for basic cations, trace metals, and total suspended solids. The loss of vegetation and changes in soil properties from the fire greatly increased the magnitude of storm runoff, resulting in sediment-laden floods carrying high concentrations of particulate-bound constituents. Post-fire concentrations and loads were up to three orders of magnitude greater than pre-fire values for many trace metals, including lead and cadmium. A shift was also observed in the timing of chemical delivery, where maximum suspended sediment, trace metal, and cation concentrations coincided with, rather than preceded, peak discharge in the post-fire runoff, amplifying the fire's impacts on mass loading. The results emphasize the importance of sediment delivery as a primary mechanism for post-fire contaminant transport and suggest that traditional management practices that focus on treating only the early portion of storm runoff may be less effective following wildfire. We also advocate that watersheds impacted by regional urban pollutants have the potential to pose significant risk for downstream communities and ecosystems after fire.

  18. Loading Concentrations of Pollutant in Alur Ilmu at UKM Bangi Campus: Event Mean Concentration (EMC) Approach

    International Nuclear Information System (INIS)

    Haslinur Md Din; Mohd Ekhwan Toriman; Mazlin Mokhtar

    2012-01-01

    Water pollutant loadings and river discharge are among the basic data used in determining the dynamicity of a river. The input of water quality and river discharge are usually available through the collection of water samples in the field or at the observatory, and are done automatically using the data logger sensor. This paper discusses the concentrations pollutant load water quality and its relationship with discharge (m 3 / s) using Event Mean Concentration (EMC) in the Alur Ilmu, UKM source from the Diptrokarp forest at Hutan Simpan Bangi (2 degree 55' 1 4.72 N 101 degree 46' 5 7.37 E). Alur Ilmu is a 1.79 km long stretching across the main campus of National University of Malaysia before flowing into the Langat River. Water quality was measured using automatic gauging and continuous water quality stations which are installed at downstream of Alur Ilmu (2 degree 55 ' 40.33 N 100 degree 46 ' 47.15 E) and involves in measuring the parameters of total dissolved solid (TDS) and dissolved oxygen (DO). Laboratory analysis carried out for chemical parameters such as ammonia nitrogen (NH 3 -N), total suspended solid (TSS), biochemical oxygen demand (BOD) and chemical oxygen demand (COD) in accordance with guidelines American Public Health Association (APHA, 1995). The normal discharge rate recorded at Alur Ilmu is 0.33 m 3 / s and the wet discharge is 13.04 m 3 / s.The total estimated pollutant loadings according to EMC as DO (18.51±3.01 mg/ L), TDS (794.92±186.72 mg/ L), BOD (11.57±0.28 mg/ L), COD (201.29±1.55 mg/ l), TSS (470.03±27.63 mg/ L) and Ammonia Nitrogen (2.52±0.0 mg/ L). Correlation test showed a direct relationship between rainfall and flow (Q) and several pollutant loadings with R 2 =1 at a significance level of 0.05. The study also classified some of the pollutants concentrations in class III and IV as determined by the Water Quality Index (WQI). (author)

  19. Airborne pollutants. Transports, effects and critical loads; Lufttransporterte forurensninger. Tilfoersler, virkninger og taalegrenser

    Energy Technology Data Exchange (ETDEWEB)

    Floeysand, I; Loebersli, E [eds.

    1996-01-01

    The report from a conference concerns two Norwegian research programmes. The first one deals with the transports and effects of airborne pollutants, and the second one relates to the critical loads of nature. A number of 17 papers from the conference are prepared. 318 refs., 57 figs., 22 tabs.

  20. Design procedure for pollutant loadings and impacts for highway stormwater runoff (Macintosh version) (for microcomputers). Software

    International Nuclear Information System (INIS)

    1990-01-01

    The interactive computer program was developed to make a user friendly procedure for the personal computer for calculations and guidance to make estimations of pollutant loadings and impacts from highway stormwater runoff which are presented in the Publication FHWA-RD-88-006, Pollutant Loadings and Impacts from Highway Stormwater Runoff, Volume I: Design Procedure. The computer program is for the evaluation of the water quality impact from highway stormwater runoff to a lake or a stream from a specific highway site considering the necessary rainfall data and geographic site situation. The evaluation considers whether or not the resulting water quality conditions can cause a problem as indicated by the violations of water quality criteria or objectives

  1. Design procedure for pollutant loadings and impacts for highway stormwater runoff (IBM version) (for microcomputers). Software

    International Nuclear Information System (INIS)

    1990-01-01

    The interactive computer program was developed to make a user friendly procedure for the personal computer for calculations and guidance to make estimations of pollutant loadings and impacts from highway stormwater runoff which are presented in the Publication FHWA-RD-88-006, Pollutant Loadings and Impacts from Highway Stormwater Runoff, Volume I: Design Procedure. The computer program is for the evaluation of the water quality impact from highway stormwater runoff to a lake or a stream from a specific highway site considering the necessary rainfall data and geographic site situation. The evaluation considers whether or not the resulting water quality conditions can cause a problem as indicated by the violations of water quality criteria or objectives

  2. Activation of peroxymonosulfate by graphitic carbon nitride loaded on activated carbon for organic pollutants degradation

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Mingyu; Gao, Long; Li, Jun [School of Environmental Engineering, Wuhan Textile University, Wuhan 430073 (China); Fang, Jia [School of Chemistry and Chemical Engineering, Wuhan Textile University, Wuhan 430073 (China); Cai, Wenxuan [School of Environmental Engineering, Wuhan Textile University, Wuhan 430073 (China); Li, Xiaoxia [School of Chemistry and Chemical Engineering, Wuhan Textile University, Wuhan 430073 (China); Xu, Aihua, E-mail: xahspinel@sina.com [School of Environmental Engineering, Wuhan Textile University, Wuhan 430073 (China); Engineering Research Center for Clean Production of Textile Dyeing and Printing, Ministry of Education, Wuhan 430073 (China)

    2016-10-05

    Highlights: • Supported g-C{sub 3}N{sub 4} on AC catalysts with different loadings were prepared. • The metal free catalysts exhibited high efficiency for dyes degradation with PMS. • The catalyst presented a long-term stability for multiple runs. • The C=O groups played a key role in the oxidation process. - Abstract: Graphitic carbon nitride supported on activated carbon (g-C{sub 3}N{sub 4}/AC) was prepared through an in situ thermal approach and used as a metal free catalyst for pollutants degradation in the presence of peroxymonosulfate (PMS) without light irradiation. It was found that g-C{sub 3}N{sub 4} was highly dispersed on the surface of AC with the increase of surface area and the exposition of more edges and defects. The much easier oxidation of C species in g-C{sub 3}N{sub 4} to C=O was also observed from XPS spectra. Acid Orange 7 (AO7) and other organic pollutants could be completely degraded by the g-C{sub 3}N{sub 4}/AC catalyst within 20 min with PMS, while g-C{sub 3}N{sub 4}+PMS and AC+PMS showed no significant activity for the reaction. The performance of the catalyst was significantly influenced by the amount of g-C{sub 3}N{sub 4} loaded on AC; but was nearly not affected by the initial solution pH and reaction temperature. In addition, the catalysts presented good stability. A nonradical mechanism accompanied by radical generation (HO· and SO{sub 4}·{sup −}) in AO7 oxidation was proposed in the system. The C=O groups play a key role in the process; while the exposure of more N-(C){sub 3} group can further increase its electron density and basicity. This study can contribute to the development of green materials for sustainable remediation of aqueous organic pollutants.

  3. Comparison of heavy metal loads in stormwater runoff from major and minor urban roads using pollutant yield rating curves

    International Nuclear Information System (INIS)

    Davis, Brett; Birch, Gavin

    2010-01-01

    Trace metal export by stormwater runoff from a major road and local street in urban Sydney, Australia, is compared using pollutant yield rating curves derived from intensive sampling data. The event loads of copper, lead and zinc are well approximated by logarithmic relationships with respect to total event discharge owing to the reliable appearance of a first flush in pollutant mass loading from urban roads. Comparisons of the yield rating curves for these three metals show that copper and zinc export rates from the local street are comparable with that of the major road, while lead export from the local street is much higher, despite a 45-fold difference in traffic volume. The yield rating curve approach allows problematic environmental data to be presented in a simple yet meaningful manner with less information loss. - A simple method for representing data onroad runoff pollution allows comparisons among dissimilar sites and could form the basis for a pollution database.

  4. The Firstflush of Pollutants in Surface Runoff

    OpenAIRE

    Pejman Razi; Amir Taebi

    2005-01-01

    One of the factors impacting quality of water resources is pollution due to urban storm runoff during first stage of storm runoff and is commonly called "firsflush". At this stage the pollution load is rather high. However, if this pollution is properly controlled and managed, the size of the required treatment facilities will be considerably reduced. The surface runoff pollution in the city of Isfahan is high and necessitates the implementation of some control system. For this purpose, ten r...

  5. Identification of hotspots and trends of fecal surface water pollution in developing countries

    Science.gov (United States)

    Reder, Klara; Flörke, Martina; Alcamo, Joseph

    2015-04-01

    Water is the essential resource ensuring human life on earth, which can only prosper when water is available and accessible. But of importance is not only the quantity of accessible water but also its quality, which in case of pollution may pose a risk to human health. The pollutants which pose a risk to human health are manifold, covering several groups such as pathogens, nutrients, human pharmaceuticals, heavy metals, and others. With regards to human health, pathogen contamination is of major interest as 4% of all death and 5.7% of disability or ill health in the world can be attributed to poor water supply, sanitation and personal and domestic hygiene. In developing countries, 2.6 billion people lacked access to improved sanitation in 2011. The lack of sanitation poses a risk to surface water pollution which is a threat to human health. A typical indicator for pathogen pollution is fecal coliform bacteria. The objective our study is to assess fecal pollution in the developing regions Africa, Asia and Latin America using the large-scale water quality model WorldQual. Model runs were carried-out to calculate in-stream concentrations and the respective loadings reaching rivers for the time period 1990 to 2010. We identified hotspots of fecal coliform loadings and in-stream concentrations which were further analyzed and ranked in terms of fecal surface water pollution. Main findings are that loadings mainly originate from the domestic sector, thus loadings are high in highly populated areas. In general, domestic loadings can be attributed to the two subsectors domestic sewered and domestic non sewered. The spatial distribution of both sectors varies across catchments. Hotspot pattern of in-stream concentrations are similar to the loadings pattern although they are different in seasonality. As the dilution varies with climate its dilution capacity is high during seasons with high precipitation, which in turn decreases the in-stream concentrations. The fecal

  6. Watershed model calibration framework developed using an influence coefficient algorithm and a genetic algorithm and analysis of pollutant discharge characteristics and load reduction in a TMDL planning area.

    Science.gov (United States)

    Cho, Jae Heon; Lee, Jong Ho

    2015-11-01

    required to achieve the water quality standard was estimated. The R(2) value for the calibrated BOD5 was 0.60, which is a moderate result, and the R(2) value for the TP was 0.86, which is a good result. The percent differences obtained for the calibrated BOD5 and TP were very good; therefore, the calibration results using WMCIG were satisfactory. From the load duration curve analysis, the WQS exceedance frequencies of the BOD5 under dry conditions and low-flow conditions were 75.7% and 65%, respectively, and the exceedance frequencies under moist and mid-range conditions were higher than under other conditions. The exceedance frequencies of the TP for the high-flow, moist and mid-range conditions were high and the exceedance rate for the high-flow condition was particularly high. Most of the data from the high-flow conditions exceeded the WQSs. Thus, nonpoint-source pollutants from storm-water runoff substantially affected the TP concentration in the Gomakwoncheon. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. National implementation of the UNECE convention on long-range transboundary air pollution (effects). Pt. 1. Deposition loads: methods, modelling and mapping results, trends

    Energy Technology Data Exchange (ETDEWEB)

    Gauger, Thomas [Federal Agricultural Research Centre, Braunschweig (DE). Inst. of Agroecology (FAL-AOE); Stuttgart Univ. (Germany). Inst. of Navigation; Haenel, Hans-Dieter; Roesemann, Claus [Federal Agricultural Research Centre, Braunschweig (DE). Inst. of Agroecology (FAL-AOE)

    2008-09-15

    The report on the implementation of the UNECE convention on long-range transboundary air pollution Pt.1, deposition loads (methods, modeling and mapping results, trends) includes the following chapters: Introduction, deposition on air pollutants used for the input for critical loads in exceeding calculations, methods applied for mapping total deposition loads, mapping wet deposition, wet deposition mapping results, mapping dry deposition, dry deposition mapping results, cloud and fog mapping results, total deposition mapping results, modeling the air concentration of acidifying components and heavy metals, agricultural emissions of acidifying and eutrophying species.

  8. Contribution of domestic wastewater to the total pollutant loading influent to a municipal wastewater treatment plant; Contribuciond e las aguas residuales domesticas a la carga total que accede a una EDAr municipal

    Energy Technology Data Exchange (ETDEWEB)

    Marin Galvin, R.; Perez de Siles, L. A.; Rojas Moreno, F. J.; Gonzalez Jimenez, M. M.

    2004-07-01

    A study on the purely domestic wastewater from Cordoba city (Abril to july 2003) has found a pollutant loading very high on these domestic wastewaters, by showing mean values of suspended solid, BOD{sub 5} and COD equal to respectively 452 mg/l, 505 mg/1 and 793 mg/l. This pollutants power probably emanates from the products for domestic cleaning used in our homes and must be associated to chemicals as citrates, oxalates, surfactants, polialcohols, organics complexing, ammonium compounds..., which show high value of pollutant loading up to 200 mg/l of BOD{sub 5} per ml of product have been measured on a commercial domestic dishwasher, and 9.000 mg/l of DQO for a domestic smoothing. Furthermore, the increasing use of pre-cooked foods can add to domestic wastewater fats, oils, and flours which can also increase the BOD:5 and COD values of these effluents. On the other hand, the measured pollutant loading or domestic wastewater from monofamily homes has been lower than those from multifamily buildings. Finally, due to the fact that the Golondrina's WWTP (Cordoba, 1991) was designed for treat values of suspended solids, BOD, and COD lower than those actually detected, its treatment processes should be probably modified in a near future. (Author) 24 refs.

  9. A comparative study of noise pollution levels in some selected areas in Ilorin Metropolis, Nigeria.

    Science.gov (United States)

    Oyedepo, Olayinka S; Saadu, Abdullahi A

    2009-11-01

    The noise pollution is a major problem for the quality of life in urban areas. This study was conducted to compare the noise pollution levels at busy roads/road junctions, passengers loading parks, commercial, industrial and residential areas in Ilorin metropolis. A total number of 47-locations were selected within the metropolis. Statistical analysis shows significant difference (P noise pollution levels between industrial areas and low density residential areas, industrial areas and high density areas, industrial areas and passengers loading parks, industrial areas and commercial areas, busy roads/road junctions and low density areas, passengers loading parks and commercial areas and commercial areas and low density areas. There is no significant difference (P > 0.05) in noise pollution levels between industrial areas and busy roads/road junctions, busy roads/road junctions and high density areas, busy roads/road junctions and passengers loading parks, busy roads/road junctions and commercial areas, passengers loading parks and high density areas, passengers loading parks and commercial areas and commercial areas and high density areas. The results show that Industrial areas have the highest noise pollution levels (110.2 dB(A)) followed by busy roads/Road junctions (91.5 dB(A)), Passengers loading parks (87.8 dB(A)) and Commercial areas (84.4 dB(A)). The noise pollution levels in Ilorin metropolis exceeded the recommended level by WHO at 34 of 47 measuring points. It can be concluded that the city is environmentally noise polluted and road traffic and industrial machineries are the major sources of it. Noting the noise emission standards, technical control measures, planning and promoting the citizens awareness about the high noise risk may help to relieve the noise problem in the metropolis.

  10. Water Pollution Search | ECHO | US EPA

    Science.gov (United States)

    The Water Pollution Search within the Water Pollutant Loading Tool gives users options to search for pollutant loading information from Discharge Monitoring Report (DMR) and Toxic Release Inventory (TRI) data.

  11. Application of the SWAT model to an AMD-affected river (Meca River, SW Spain). Estimation of transported pollutant load

    Science.gov (United States)

    Galván, L.; Olías, M.; Fernandez de Villarán, R.; Domingo Santos, J. M.; Nieto, J. M.; Sarmiento, A. M.; Cánovas, C. R.

    2009-10-01

    SummaryThe Meca River is highly contaminated by acid mine drainage coming from the Tharsis mining district, belonging to the Iberian Pyrite Belt. This river is regulated by the Sancho reservoir (58 hm 3), with a pH close to 4.2. In this work, the load transported by the Meca River to the Sancho reservoir has been assessed. Due to the lack of streamflow data, the hydrological behaviour of the Meca River basin has been simulated using the SWAT model. The model has been calibrated against registered daily inflows of the Sancho reservoir (1982-2000), excluding the hydrological years 2000/2001 and 2001/2002 that were kept for the validation. The results were satisfactory; the evaluation coefficients for monthly calibration were: r = 0.85 (Pearson's correlation coefficient), NSE = 0.83 (Nash-Sutcliffe coefficient) and DV = 1.08 (runoff volume deviation). The main uncertainty was the calibration during low water because of the poor accuracy in the measurement of the inputs to the reservoir in these conditions. Discharge and dissolved concentration relationships for different elements were obtained from hydrochemical samplings, which allowed us to estimate the element pollutant load transported to the reservoir: 418 ton/year of Al, 8024 ton/year of SO 4, 121 ton/year of Zn, etc. Based on these loads, concentrations in the reservoir were calculated for some elements. Apart from Mn and Sr, good adjustment between calculated and measured values was observed (±20% for Ca, Co, Li, Mg, Na, Ni, Zn and SO 4). Capsule: Hydrological model combined with water quality data show how pollution by AMD can generate huge loads of contaminants acidifying streams and reservoirs.

  12. Application of stable isotopes to the assessment of pollution loading from various sources in the Pampanga River system into the Manila Bay, Philippines

    International Nuclear Information System (INIS)

    2013-01-01

    The study focuses on the Pampanga River Basin as prototype for the other watersheds of Manila Bay. The pollution of the Bay is associated to loading from agriculture, industry and services sectors but with no direct evidence, hence the origins of pollution have to be identified for area-based resource management actions. The multiple stable isotopes were used and applied in identifying and tracing through spectral signature the origin of nutrient loading

  13. High thermal load receiving heat plate

    International Nuclear Information System (INIS)

    Shibutani, Jun-ichi; Shibayama, Kazuhito; Yamamoto, Keiichi; Uchida, Takaho.

    1993-01-01

    The present invention concerns a high thermal load heat receiving plate such as a divertor plate of a thermonuclear device. The high thermal load heat receiving plate of the present invention has a cooling performance capable of suppressing the temperature of an armour tile to less than a threshold value of the material against high thermal loads applied from plasmas. Spiral polygonal pipes are inserted in cooling pipes at a portion receiving high thermal loads in the high temperature load heat receiving plate of the present invention. Both ends of the polygonal pipes are sealed by lids. An area of the flow channel in the cooling pipes is thus reduced. Heat conductivity on the cooling surface of the cooling pipes is increased in the high thermal load heat receiving plate having such a structure. Accordingly, temperature elevation of the armour tile can be suppressed. (I.S.)

  14. Perceived air quality and sensory pollution loads in six Danish office buildings

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Krupicz, P.; Szczecinski, A.

    2002-01-01

    Perceived air quality and sensory pollution loads were measured in 6 office buildings with mechanical ventilation without recirculation, in each buildings in 6 representative non-smoking medium-sized and small offices with mixing ventilation. An untrained panel of 43 subjects assessed the air...... quality on a normal weekday when the building was occupied, and on a weekend without occupants in the building. On both occasions the ventilation system was in operation as on a normal working day. Outdoor air supply rate, air temperature, relative humidity, concentration of carbon dioxide and ultrafine...

  15. Vehicular pollution modeling using the operational street pollution model (OSPM) for Chembur, Mumbai (India)

    DEFF Research Database (Denmark)

    Kumar, Awkash; Ketzel, Matthias; Patil, Rashmi S.

    2016-01-01

    Megacities in India such as Mumbai and Delhi are among the most polluted places in the world. In the present study, the widely used operational street pollution model (OSPM) is applied for assessing pollutant loads in the street canyons of Chembur, a suburban area just outside Mumbai city. Chembur...... concentrations from the routine monitoring performed in Mumbai. NOx emissions originate mainly from vehicles which are ground-level sources and are emitting close to where people live. Therefore, those emissions are highly relevant. The modeled NOx concentration compared satisfactorily with observed data...

  16. Application of modified export coefficient method on the load estimation of non-point source nitrogen and phosphorus pollution of soil and water loss in semiarid regions.

    Science.gov (United States)

    Wu, Lei; Gao, Jian-en; Ma, Xiao-yi; Li, Dan

    2015-07-01

    Chinese Loess Plateau is considered as one of the most serious soil loss regions in the world, its annual sediment output accounts for 90 % of the total sediment loads of the Yellow River, and most of the Loess Plateau has a very typical characteristic of "soil and water flow together", and water flow in this area performs with a high sand content. Serious soil loss results in nitrogen and phosphorus loss of soil. Special processes of water and soil in the Loess Plateau lead to the loss mechanisms of water, sediment, nitrogen, and phosphorus are different from each other, which are greatly different from other areas of China. In this study, the modified export coefficient method considering the rainfall erosivity factor was proposed to simulate and evaluate non-point source (NPS) nitrogen and phosphorus loss load caused by soil and water loss in the Yanhe River basin of the hilly and gully area, Loess Plateau. The results indicate that (1) compared with the traditional export coefficient method, annual differences of NPS total nitrogen (TN) and total phosphorus (TP) load after considering the rainfall erosivity factor are obvious; it is more in line with the general law of NPS pollution formation in a watershed, and it can reflect the annual variability of NPS pollution more accurately. (2) Under the traditional and modified conditions, annual changes of NPS TN and TP load in four counties (districts) took on the similar trends from 1999 to 2008; the load emission intensity not only is closely related to rainfall intensity but also to the regional distribution of land use and other pollution sources. (3) The output structure, source composition, and contribution rate of NPS pollution load under the modified method are basically the same with the traditional method. The average output structure of TN from land use and rural life is about 66.5 and 17.1 %, the TP is about 53.8 and 32.7 %; the maximum source composition of TN (59 %) is farmland; the maximum source

  17. Contributions of wastewater, runoff and sewer deposit erosion to wet weather pollutant loads in combined sewer systems.

    Science.gov (United States)

    Gasperi, J; Gromaire, M C; Kafi, M; Moilleron, R; Chebbo, G

    2010-12-01

    An observatory of urban pollutants was created in Paris for the purpose of assessing the dynamics of wastewater and wet weather flow (WW and WWF) pollutant loads within combined sewers. This observatory is composed of six urban catchments, covering land areas ranging in size from 42 ha to 2581 ha. For a wide array of parameters including total suspended solids (TSS), chemical and biochemical oxygen demand (COD and BOD(5)), total organic carbon (TOC), total Kjeldahl nitrogen (TKN), heavy metals (Cu and Zn) and polycyclic aromatic hydrocarbons (PAHs), this article is intended to evaluate the contributions of wastewater, runoff and in-sewer processes to WWF pollutant loads through the use of an entry-exit mass balance approach. To achieve this objective, a total of 16 rain events were sampled on these sites between May 2003 and February 2006. This study has confirmed that at the considered catchment scale (i.e. from 42 ha to 2581 ha) the production and transfer processes associated with WWF pollutant loads do not vary with basin scale. Entry-exit chemical mass balances over all catchments and for a large number of rain events indicate that wastewater constitutes the main source of organic and nitrogenous pollution, while runoff is the predominant source of Zn. For Cu, PAHs and TSS, the calculation underscores the major role played by in-sewer processes, specifically by sediment erosion, as a source of WWF pollution. A significant loss of dissolved metals was also observed during their transfer within the sewer network, likely as a consequence of the adsorption of dissolved metals on TSS and/or on sewer deposits. Moreover, the nature of eroded particles was examined and compared to the various sewer deposits. This comparison has highlighted that such particles exhibit similar organic and PAH contents to those measured in the organic layer, thus suggesting that the deposit eroded during a wet weather period is organic and of a nature comparable to the organic layer

  18. Simulation of Water Environmental Capacity and Pollution Load Reduction Using QUAL2K for Water Environmental Management

    Science.gov (United States)

    Zhang, Ruibin; Qian, Xin; Yuan, Xingcheng; Ye, Rui; Xia, Bisheng; Wang, Yulei

    2012-01-01

    In recent years, water quality degradation associated with rapid socio-economic development in the Taihu Lake Basin, China, has attracted increasing attention from both the public and the Chinese government. The primary sources of pollution in Taihu Lake are its inflow rivers and their tributaries. Effective water environmental management strategies need to be implemented in these rivers to improve the water quality of Taihu Lake, and to ensure sustainable development in the region. The aim of this study was to provide a basis for water environmental management decision-making. In this study, the QUAL2K model for river and stream water quality was applied to predict the water quality and environmental capacity of the Hongqi River, which is a polluted tributary in the Taihu Lake Basin. The model parameters were calibrated by trial and error until the simulated results agreed well with the observed data. The calibrated QUAL2K model was used to calculate the water environmental capacity of the Hongqi River, and the water environmental capacities of CODCr NH3-N, TN, and TP were 17.51 t, 1.52 t, 2.74 t and 0.37 t, respectively. The results showed that the NH3-N, TN, and TP pollution loads of the studied river need to be reduced by 50.96%, 44.11%, and 22.92%, respectively to satisfy the water quality objectives. Thus, additional water pollution control measures are needed to control and reduce the pollution loads in the Hongqi River watershed. The method applied in this study should provide a basis for water environmental management decision-making. PMID:23222206

  19. Simulation of water environmental capacity and pollution load reduction using QUAL2K for water environmental management.

    Science.gov (United States)

    Zhang, Ruibin; Qian, Xin; Yuan, Xingcheng; Ye, Rui; Xia, Bisheng; Wang, Yulei

    2012-12-07

    In recent years, water quality degradation associated with rapid socio-economic development in the Taihu Lake Basin, China, has attracted increasing attention from both the public and the Chinese government. The primary sources of pollution in Taihu Lake are its inflow rivers and their tributaries. Effective water environmental management strategies need to be implemented in these rivers to improve the water quality of Taihu Lake, and to ensure sustainable development in the region. The aim of this study was to provide a basis for water environmental management decision-making. In this study, the QUAL2K model for river and stream water quality was applied to predict the water quality and environmental capacity of the Hongqi River, which is a polluted tributary in the Taihu Lake Basin. The model parameters were calibrated by trial and error until the simulated results agreed well with the observed data. The calibrated QUAL2K model was used to calculate the water environmental capacity of the Hongqi River, and the water environmental capacities of COD(Cr) NH(3)-N, TN, and TP were 17.51 t, 1.52 t, 2.74 t and 0.37 t, respectively. The results showed that the NH(3)-N, TN, and TP pollution loads of the studied river need to be reduced by 50.96%, 44.11%, and 22.92%, respectively to satisfy the water quality objectives. Thus, additional water pollution control measures are needed to control and reduce the pollution loads in the Hongqi River watershed. The method applied in this study should provide a basis for water environmental management decision-making.

  20. Simulation of Water Environmental Capacity and Pollution Load Reduction Using QUAL2K for Water Environmental Management

    Directory of Open Access Journals (Sweden)

    Yulei Wang

    2012-12-01

    Full Text Available In recent years, water quality degradation associated with rapid socio-economic development in the Taihu Lake Basin, China, has attracted increasing attention from both the public and the Chinese government. The primary sources of pollution in Taihu Lake are its inflow rivers and their tributaries. Effective water environmental management strategies need to be implemented in these rivers to improve the water quality of Taihu Lake, and to ensure sustainable development in the region. The aim of this study was to provide a basis for water environmental management decision-making. In this study, the QUAL2K model for river and stream water quality was applied to predict the water quality and environmental capacity of the Hongqi River, which is a polluted tributary in the Taihu Lake Basin. The model parameters were calibrated by trial and error until the simulated results agreed well with the observed data. The calibrated QUAL2K model was used to calculate the water environmental capacity of the Hongqi River, and the water environmental capacities of CODCr NH3-N, TN, and TP were 17.51 t, 1.52 t, 2.74 t and 0.37 t, respectively. The results showed that the NH3-N, TN, and TP pollution loads of the studied river need to be reduced by 50.96%, 44.11%, and 22.92%, respectively to satisfy the water quality objectives. Thus, additional water pollution control measures are needed to control and reduce the pollution loads in the Hongqi River watershed. The method applied in this study should provide a basis for water environmental management decision-making.

  1. Water Quality Improvement through Reductions of Pollutant Loads on Small Scale of Bioretention System

    Science.gov (United States)

    Elyza Muha, Norshafa; Mohd Sidek, Lariyah; Jajarmizadeh, Milad

    2016-03-01

    Bioretention system is introduced as an important topic namely Urban Storm Water Management Manual for Malaysia (MSMA) by the Department of Irrigation and Drainage Malaysia (DID) in May 2012. The main objective of this paper is to evaluate the performance of water quality for small scale bioretention system under tropical climate via MUSIC model. Two bioretention systems 1 and 2 are observed based on the difference media depth. The result of bioretention system is compared with a reference model which has infrastructure with Urban Stormwater Improvement Conceptualisation (MUSIC) for pollutants load reduction and water quality results. Assessment of results via MUSIC software indicates a significant percentage of reduction for Total Suspended Solid (TSS), Total Phosphorus (TP) and Total Nitrogen (TN). The prediction of pollutant reduction via using MUSIC has the harmony for requirement in MSMA. TSS pollutant reduction is more than 80%, while for TP and TN more than 50%. The outcome of this study can be helpful for improvement of the existing MSMA guidelines for application of bioretention systems in Malaysia.

  2. A comparison of Alpine emissions to forest soil and spruce needle loads for persistent organic pollutants (POPs)

    Energy Technology Data Exchange (ETDEWEB)

    Belis, C.A., E-mail: claudio.belis@jrc.ec.europa.e [Regional Agency for Environmental Protection of Lombardia (Italy); Offenthaler, I.; Uhl, M.; Nurmi-Legat, J. [Umweltbundesamt GmbH (Austria); Bassan, R. [Regional Agency for Environmental Prevention and Protection of Veneto (Italy); Jakobi, G.; Kirchner, M. [Helmholtz Zentrum Muenchen, German Research Centre for Environment and Health (Germany); Knoth, W. [German Federal Environmental Agency (Germany); Kraeuchi, N. [WSL Swiss Federal Institute for Forest, Snow and Landscape Research (Switzerland); Levy, W. [Helmholtz Zentrum Muenchen, German Research Centre for Environment and Health (Germany); Magnani, T. [Regional Agency for Environmental Protection of Lombardia (Italy); Moche, W. [Umweltbundesamt GmbH (Austria); Schramm, K.-W. [Regional Agency for Environmental Prevention and Protection of Veneto (Italy); Simoncic, P. [Slovenian Forestry Institute (Slovenia); Weiss, P. [Umweltbundesamt GmbH (Austria)

    2009-12-15

    The project MONARPOP analysed the concentrations of semivolatile organic compounds (SVOCs) in two important sink compartments, needles of Norway spruce (Picea abies [L.] Karst.) and forest soil from 40 remote Alpine forest sites in Austria, Germany, Italy, Slovenia and Switzerland. In the present study the load of PCDD/F, PCB, PBDE, PAH, HCB, HCH and DDT in the Alps calculated on the basis of measured data are compared with their estimated emissions in the Alpine region. It comes out that the masses of the studied pollutants stored in the forests are higher than the corresponding emissions in the Alpine area indicating that the Alps are a sink for POPs advected from surrounding areas. It is assumed that local emissions of PCDD/F and PAH deriving from biomass burning are probably underestimated and that the pool of these pollutants in the forests represents the accumulation over some decades. - The loads of POPs in the Alps are higher than their emissions in the Alpine region.

  3. Attentional capture under high perceptual load.

    Science.gov (United States)

    Cosman, Joshua D; Vecera, Shaun P

    2010-12-01

    Attentional capture by abrupt onsets can be modulated by several factors, including the complexity, or perceptual load, of a scene. We have recently demonstrated that observers are less likely to be captured by abruptly appearing, task-irrelevant stimuli when they perform a search that is high, as opposed to low, in perceptual load (Cosman & Vecera, 2009), consistent with perceptual load theory. However, recent results indicate that onset frequency can influence stimulus-driven capture, with infrequent onsets capturing attention more often than did frequent onsets. Importantly, in our previous task, an abrupt onset was present on every trial, and consequently, attentional capture might have been affected by both onset frequency and perceptual load. In the present experiment, we examined whether onset frequency influences attentional capture under conditions of high perceptual load. When onsets were presented frequently, we replicated our earlier results; attentional capture by onsets was modulated under conditions of high perceptual load. Importantly, however, when onsets were presented infrequently, we observed robust capture effects. These results conflict with a strong form of load theory and, instead, suggest that exposure to the elements of a task (e.g., abrupt onsets) combines with high perceptual load to modulate attentional capture by task-irrelevant information.

  4. The estimation of the load of non-point source nitrogen and phosphorus based on observation experiments and export coefficient method in Three Gorges Reservoir Area

    Science.gov (United States)

    Tong, X. X.; Hu, B.; Xu, W. S.; Liu, J. G.; Zhang, P. C.

    2017-12-01

    In this paper, Three Gorges Reservoir Area (TGRA) was chosen to be the study area, the export coefficients of different land-use type were calculated through the observation experiments and literature consultation, and then the load of non-point source (NPS) nitrogen and phosphorus of different pollution sources such as farmland pollution sources, decentralized livestock and poultry breeding pollution sources and domestic pollution sources were estimated. The results show as follows: the pollution load of dry land is the main source of farmland pollution. The order of total nitrogen load of different pollution sources from high to low is livestock breeding pollution, domestic pollution, land use pollution, while the order of phosphorus load of different pollution sources from high to low is land use pollution, livestock breeding pollution, domestic pollution, Therefore, reasonable farmland management, effective control methods of dry land fertilization and sewage discharge of livestock breeding are the keys to the prevention and control of NPS nitrogen and phosphorus in TGRA.

  5. Water quality of the Neuse River, North Carolina - Variability, pollution loads, and long-term trends

    Science.gov (United States)

    Harned, Doughlas A.

    1982-01-01

    Interpretation of water-quality data collected by the U.S. Geological Survey for the Neuse River, North Carolina, has identified water-quality variations, charactrized the current condition of the river in reference to water-quality standards, estimated the degree of pollution caused by man, and evaluated long-term trends in concentrations of major dissolved constituents. Two sampling stations, Neuse River near Clayton (02087500) and Neuse River at Kinston (02089500) have more than 12 years of water-quality data collected during the period from 1955 to 1978. The Clayton station provides information on the upper fourth of the basin (1,129 mi 2) which includes several urbanized areas, including Raleigh, N.C., and part of Durham, N.C. The Kinston station provides information from the predominantly rural midsection of the basin (2,690 mi2). A network of temporary stations on small rural streams in the Neuse River and adjacent basins provide an estimate of baseline or es- sentially unpolluted water quality. Overall, the water quality of the Neuse River is satisfactory for most uses. However, dissolved-oxygen, iron, and manganese concentrations, pH, and bacterial concentrations often reach undesirable levels. Concentrations of cadmium, and lead also periodically peak at or above criterion levels for domestic water supply sources. Nutrient levels are generally high enough to allow rich algal growth. Sediment concentrations in the Neuse are high in comparison to pristine streams, however, the impacts of these high levels are difficult to quantify. Sediment and nutrient concentrations peak on the leading edge of flood discharges at Clayton. At Kinston, however, the discharge and sediment concentration peak almost simultaneously. Changes in algal dominance, from genera usually associated with organically enriched waters to genera that are less tolerant to organic enrichment, indicate improvement in water qualiy of the Neuse since 1973. These changes, along with a reduction

  6. Tar loads on Omani beaches

    International Nuclear Information System (INIS)

    Badawy, M.I.; Al-Harthy, F.T.

    1991-01-01

    Owing to Oman's geographic position and long coastal line, the coastal areas of Oman are particularly vulnerable to oil pollution from normal tanker operations, illegal discharges, and accidental spills as well as local sources of oil input. UNEP carried out a survey on the coasts of Oman to determine the major sources of oil pollution and concluded that the major shoreline pollution problems in Oman arose from operational discharges of oil from passing vessels traffic. The oil, because of the high sea and air temperatures in the area, was subjected to relatively high rates of evaporation and photo-oxidation and tended to arrive at the coast as heavy petroleum particulate residues (tar balls). The aim of the present study was to measure the loads of tar balls in Omani coastal areas and to identify the source of oil pollutants on beaches

  7. Design of digital load torque observer in hybrid electric vehicle

    Science.gov (United States)

    Sun, Yukun; Zhang, Haoming; Wang, Yinghai

    2008-12-01

    In hybrid electric vehicle, engine begain to work only when motor was in high speed in order to decrease tail gas emission. However, permanent magnet motor was sensitive to its load, adding engine to the system always made its speed drop sharply, which caused engine to work in low efficiency again and produced much more environment pollution. Dynamic load torque model of permanent magnet synchronous motor is established on the basic of motor mechanical equation and permanent magnet synchronous motor vector control theory, Full- digital load torque observer and compensation control system is made based on TMS320F2407A. Experiment results prove load torque observer and compensation control system can detect and compensate torque disturbing effectively, which can solve load torque disturbing and decrease gas pollution of hybrid electric vehicle.

  8. Critical levels and loads of atmospheric pollutants for terrestrial and aquatic ecosystems. The emergence of a scientific concept. Application potentials and their limits

    International Nuclear Information System (INIS)

    Landmann, G.

    1993-01-01

    The 'critical loads and levels' are defined as the highest atmospheric deposition rate or concentration of a gaseous pollutant, respectively, that will not cause harmful effects on sensitive elements of an ecosystem. The recent emergence of the concept of critical loads and levels is described, from the first explicit mention in 1986 to the production of the first European maps in 1991. The difficulties linked to the definition of the concept and to its english-derived terminology are discussed. The main approaches used for assessing critical loads and levels are briefly described. Important research is developed under the auspices of the Convention of Geneva (Long Range Transboundary Air Pollution Transport, UN-ECE), arising from intensive studies which have been carried out on the effects of air pollution on terrestrial and aquatic ecosystems for the past ten or fifteen years. Current knowledge is summarized, as well as the remaining gaps (and questions) which hinder the calculation of the critical thresholds. Finally, beyond the fundamental relevance of this scientifically sound and easily understood concept, its limits are pointed out. In brief, the 'critical loads and levels' concept is attractive and motivating to many scientists: it implies to apply an integrated and finalized approach, favors the prospecting of poorly known ecosystems and regions, and represents an interesting interface with decision makers

  9. High Temperature Radio Frequency Loads

    CERN Document Server

    Federmann, S; Grudiev, A; Montesinos, E; Syratchev, I

    2011-01-01

    In the context of energy saving and recovery requirements the design of reliable and robust RF power loads which permit a high outlet temperature and high pressure of the cooling water is desirable. Cooling water arriving at the outlet withmore than 150 ◦C and high pressure has a higher value than water with 50 ◦C under low pressure. Conventional RF power loads containing dielectric and magnetic materials as well as sensitive ceramic windows usually do not permit going much higher than 90 ◦C. Here we present and discuss several design concepts for "metal only" RF high power loads. One concept is the application of magnetic steel corrugated waveguides near cutoff – this concept could find practical use above several GHz. Another solution are resonant structures made of steel to be installed in large waveguides for frequencies of 500 MHz or lower. Similar resonant structures above 100 MHz taking advantage of the rather high losses of normal steel may also be used in coaxial line geometries with large di...

  10. Air pollution forecast in cities by an air pollution index highly correlated with meteorological variables

    International Nuclear Information System (INIS)

    Cogliani, E.

    2001-01-01

    There are many different air pollution indexes which represent the global urban air pollution situation. The daily index studied here is also highly correlated with meteorological variables and this index is capable of identifying those variables that significantly affect the air pollution. The index is connected with attention levels of NO 2 , CO and O 3 concentrations. The attention levels are fixed by a law proposed by the Italian Ministries of Health and Environment. The relation of that index with some meteorological variables is analysed by the linear multiple partial correlation statistical method. Florence, Milan and Vicence were selected to show the correlation among the air pollution index and the daily thermic excursion, the previous day's air pollution index and the wind speed. During the January-March period the correlation coefficient reaches 0.85 at Milan. The deterministic methods of forecasting air pollution concentrations show very high evaluation errors and are applied on limited areas around the observation stations, as opposed to the whole urban areas. The global air pollution, instead of the concentrations at specific observation stations, allows the evaluation of the level of the sanitary risk regarding the whole urban population. (Author)

  11. High-Energy Electron Beam Application to Air Pollutants Removal

    International Nuclear Information System (INIS)

    Ighigeanu, D.; Martin, D.; Manaila, E.; Craciun, G.; Calinescu, I.

    2009-01-01

    The advantage of electron beam (EB) process in pollutants removal is connected to its high efficiency to transfer high amount of energy directly into the matter under treatment. Disadvantage which is mostly related to high investment cost of accelerator may be effectively overcome in future as the result of use accelerator new developments. The potential use of medium to high-energy high power EB accelerators for air pollutants removal is demonstrated in [1]. The lower electrical efficiencies of accelerators with higher energies are partially compensated by the lower electron energy losses in the beam windows. In addition, accelerators with higher electron energies can provide higher beam powers with lower beam currents [1]. The total EB energy losses (backscattering, windows and in the intervening air space) are substantially lower with higher EB incident energy. The useful EB energy is under 50% for 0.5 MeV and about 95% above 3 MeV. In view of these arguments we decided to study the application of high energy EB for air pollutants removal. Two electron beam accelerators are available for our studies: electron linear accelerators ALIN-10 and ALID-7, built in the Electron Accelerator Laboratory, INFLPR, Bucharest, Romania. Both accelerators are of traveling-wave type, operating at a wavelength of 10 cm. They utilize tunable S-band magnetrons, EEV M 5125 type, delivering 2 MW of power in 4 μ pulses. The accelerating structure is a disk-loaded tube operating in the 2 mode. The optimum values of the EB peak current IEB and EB energy EEB to produce maximum output power PEB for a fixed pulse duration EB and repetition frequency fEB are as follows: for ALIN-10: EEB = 6.23 MeV; IEB =75 mA; PEB 164 W (fEB = 100 Hz, EB = 3.5 s) and for ALID-7: EEB 5.5 MeV; IEB = 130 mA; PEB = 670 W (fEB = 250 Hz, EB = 3.75 s). This paper presents a special designed installation, named SDI-1, and several representative results obtained by high energy EB application to SO 2 , NOx and VOCs

  12. [Magnetic Response of Dust-loaded Leaves in Parks of Shanghai to Atmospheric Heavy Metal Pollution].

    Science.gov (United States)

    Liu, Fei; Chu, Hui-min; Zheng, Xiang-min

    2015-12-01

    To reveal the magnetic response to the atmospheric heavy metal pollution in leaves along urban parks, Camphor leaf samples, widely distributed at urban parks, were collected along the year leading wind direction of Shanghai, by setting two vertical and horizontal sections, using rock magnetic properties and heavy metal contents analysis. The results showed that the magnetic minerals of samples were predominated by ferromagnetic minerals, and both the concentration and grain size of magnetite particles gradually decreased with the winter monsoon direction from the main industrial district. A rigorous cleaning of leaves using ultrasonic agitator washer could remove about 63%-90% of low-field susceptibility values of the leaves, and this strongly indicated that the intensity of magnetic signal was mainly controlled by the PMs accumulated on the leaves surfaces. Moreover, there was a significant linear relationship between heavy metals contents (Fe, Mn, Zn, Cu, Cr, V and Pb) and magnetic parameters (0.442 ≤ R ≤ 0.799, P atmospheric heavy metal pollution. The results of multivariate statistical analysis showed that the content of magnetic minerals and heavy metal indust-loaded tree leaves was affected by associated pollution of industry and traffic.

  13. [Mapping Critical Loads of Heavy Metals for Soil Based on Different Environmental Effects].

    Science.gov (United States)

    Shi, Ya-xing; Wu, Shao-hua; Zhou, Sheng-lu; Wang, Chun-hui; Chen, Hao

    2015-12-01

    China's rapid development of industrialization and urbanization causes the growing problem of heavy metal pollution of soil, threatening environment and human health. Therefore, prevention and management of heavy metal pollution become particularly important. Critical loads of heavy metals are an important management tool that can be utilized to prevent the occurrence of heavy metal pollution. Our study was based on three cases: status balance, water environmental effects and health risks. We used the steady-state mass balance equation to calculate the critical loads of Cd, Cu, Pb, Zn at different effect levels and analyze the values and spatial variation of critical loads. In addition, we used the annual input fluxes of heavy metals of the agro-ecosystem in the Yangtze River delta and China to estimate the proportion of area with exceedance of critical loads. The results demonstrated that the critical load value of Cd was the minimum, and the values of Cu and Zn were lager. There were spatial differences among the critical loads of four elements in the study area, lower critical loads areas mainly occurred in woodland and high value areas distributed in the east and southwest of the study area, while median values and the medium high areas mainly occurred in farmland. Comparing the input fluxes of heavy metals, we found that Pb and Zn in more than 90% of the area exceeded the critical loads under different environmental effects in the study area. The critical load exceedance of Cd mainly occurred under the status balance and the water environmental effect, while Cu under the status balance and water environmental effect with a higher proportion of exceeded areas. Critical loads of heavy metals at different effect levels in this study could serve as a reference from effective control of the emissions of heavy metals and to prevent the occurrence of heavy metal pollution.

  14. Reduction Assessment of Agricultural Non-Point Source Pollutant Loading

    OpenAIRE

    Fu, YiCheng; Zang, Wenbin; Zhang, Jian; Wang, Hongtao; Zhang, Chunling; Shi, Wanli

    2018-01-01

    NPS (Non-point source) pollution has become a key impact element to watershed environment at present. With the development of technology, application of models to control NPS pollution has become a very common practice for resource management and Pollutant reduction control in the watershed scale of China. The SWAT (Soil and Water Assessment Tool) model is a semi-conceptual model, which was put forward to estimate pollutant production & the influences on water quantity-quality under different...

  15. Quantifying the importance of diffuse minewater pollution in a historically heavily coal mined catchment

    International Nuclear Information System (INIS)

    Mayes, W.M.; Gozzard, E.; Potter, H.A.B.; Jarvis, A.P.

    2008-01-01

    There has been considerable progress in developing treatment systems for point sources of minewater pollution in recent years; however, there remains a knowledge gap in the characterisation and remediation of diffuse minewater sources. Data are presented from the River Gaunless catchment, a historically heavily coal mined catchment in the northeast of England. Instream iron (Fe) loadings were monitored alongside loadings arising from point minewater discharges over a 12-month period to assess the dynamic importance of diffuse sources of minewater pollution. In low flow, diffuse sources account for around 50% of instream loading, a proportion which increases to 98% in high flow conditions. The low flow sources appear to be dominated by direct discharge of contaminated groundwater to surface waters in lower reaches of the catchment. In high flow, resuspended Fe-rich sediments, which are both naturally occurring and derived from historic mining, become the dominant diffuse source of Fe in the water column. - Diffuse sources of minewater pollution significantly contribute to instream contaminant loadings under varying flow conditions

  16. Grey water characterisation and pollutant loads in an urban slum

    International Nuclear Information System (INIS)

    Katukiza, A. Y.; Ronteltap, M.; Niwagaba, C. B.; Kansiime, F.; Lens, P. N. L.

    2015-01-01

    On-site sanitation provisions in urban slums rarely prioritise grey water management, yet it forms the largest fraction of wastewater. This study was carried out to characterise grey water and quantify its pollutant loads in Bwaise III (Uganda) and to provide data for grey water management in urban slums of developing countries. Samples were collected for analysis from ten representative households as well as from four tertiary drains and the main drainage channel for 7 months in two dry seasons. Grey water production was found to comprise 85 % of the domestic water consumption. The chemical oxygen demand concentration in the grey water generated by laundry, in the kitchen and in the bathroom was 9,225 ± 1,200 mg L-1, 71,250 ± 1,011 mg L-1 and 4,675 ± 750 mg L-1, while the BOD5 (biochemical oxygen demand) to COD ratio was 0.24 ± 0.05, 0.33 ± 0.08 and 0.31 ± 0.07, respectively. The maximum concentration of Escherichia coli and total coliforms was 2.05 9 107 cfu (100 mL)-1 and 1.75 9 108 cfu (100 mL)-1, respectively, in grey water from the bathroom, while that of Salmonella spp. was 7.32 9 106 cfu (100 mL)-1 from laundry. Analysis of variance (ANOVA) showed a significant difference in the concentration of COD, total suspended solids, total organic carbon, dissolved organic carbon, total phosphorus, sodium adsorption ratio, oil and grease, and Salmonella spp. in grey water from laundry, bathroom and kitchen (p/0.05). The high loads of COD ([500 kg day-1), total suspended solids ([200 kg day-1), nutrients (8.3 kg TKN day-1 and 1.4 kg total phosphorus day-1) and microorganisms (106 to 109 cfu c-1 day-1) originating from grey water in Bwaise III show that grey water poses a threat to the environment and a risk to human health in urban slums. Therefore, there is a need to prioritise grey water treatment in urban slums of developing countries to achieve adequate sanitation.

  17. Air pollution and floristic biodiversity; Pollution atmospherique et biodiversite floristique

    Energy Technology Data Exchange (ETDEWEB)

    Grub, A.; Bungener, P.; Contat, F.; Nussbaum, S.; Endtner, V.; Fuhrer, J. [Station Federale de Recherches en Agroecologie et Agriculture (FAL), Liebefeld-Berne (Switzerland). Institut de Recherches en Protection de l' Environnement et en Agriculture (IUL)

    1999-06-01

    The number of reports on negative effects of air pollution on biodiversity is increasing. Here, examples from the literature are presented which concern effects of fluoride, deposition of nitrogen, and ozone. Today, nitrogen loads and levels of tropospheric ozone seem to be most relevant forms of air pollution affecting species diversity of the flora. Results from recent investigations of ozone effects at Liebefeld indicate that the loss of floristic diversity in permanent meadows is possible because of the high relative sensitivity of some typical species. Further studies will be necessary to validate the results obtained from experiment with single plants at the level of the intact plant community in the field, and to identify the critical level of ozone to protect the floristic biodiversity of meadows. (authors)

  18. Epiphytic lichen diversity on dead and dying conifers under different levels of atmospheric pollution

    International Nuclear Information System (INIS)

    Hauck, Markus

    2005-01-01

    Based on literature data, epiphytic lichen abundance was comparably studied in montane woodlands on healthy versus dead or dying conifers of Europe and North America in areas with different levels of atmospheric pollution. Study sites comprised Picea abies forests in the Harz Mountains and in the northern Alps, Germany, Picea rubens-Abies balsamea forests on Whiteface Mountain, Adirondacks, New York, U.S.A. and Picea engelmannii-Abies lasiocarpa forests in the Salish Mountains, Montana, U.S.A. Detrended correspondence analysis showed that epiphytic lichen vegetation differed more between healthy and dead or dying trees at high- versus low-polluted sites. This is attributed to greater differences in chemical habitat conditions between trees of different vitality in highly polluted areas. Based on these results, a hypothetical model of relative importance of site factors for small-scale variation of epiphytic lichen abundance versus atmospheric pollutant load is discussed. - Epiphytic lichen diversity differs increasingly between healthy and dead or dying conifers with increasing atmospheric pollutant load

  19. Will urban expansion lead to an increase in future water pollution loads?--a preliminary investigation of the Haihe River Basin in northeastern China.

    Science.gov (United States)

    Dong, Yang; Liu, Yi; Chen, Jining

    2014-01-01

    Urban expansion is a major driving force changing regional hydrology and nonpoint source pollution. The Haihe River Basin, the political, economic, and cultural center of northeastern China, has undergone rapid urbanization in recent decades. To investigate the consequences of future urban sprawl on nonpoint source water pollutant emissions in the river basin, the urban sprawl in 2030 was estimated, and the annual runoff and nonpoint source pollution in the Haihe River basin were simulated. The Integrated Model of Non-Point Sources Pollution Processes (IMPULSE) was used to simulate the effects of urban sprawl on nonpoint source pollution emissions. The outcomes indicated that the urban expansion through 2030 increased the nonpoint source total nitrogen (TN), total phosphorous (TP), and chemical oxygen demand (COD) emissions by 8.08, 0.14, and 149.57 kg/km(2), respectively. Compared to 2008, the total nonpoint emissions rose by 15.33, 0.57, and 12.39 %, respectively. Twelve percent of the 25 cities in the basin would increase by more than 50 % in nonpoint source TN and COD emissions in 2030. In particular, the nonpoint source TN emissions in Xinxiang, Jiaozuo, and Puyang would rise by 73.31, 67.25, and 58.61 %, and the nonpoint source COD emissions in these cities would rise by 74.02, 51.99, and 53.27 %, respectively. The point source pollution emissions in 2008 and 2030 were also estimated to explore the effects of urban sprawl on total water pollution loads. Urban sprawl through 2030 would bring significant structural changes of total TN, TP, and COD emissions for each city in the area. The results of this study could provide insights into the effects of urbanization in the study area and the methods could help to recognize the role that future urban sprawl plays in the total water pollution loads in the water quality management process.

  20. Non-Point Source Pollutant Load Variation in Rapid Urbanization Areas by Remote Sensing, Gis and the L-THIA Model: A Case in Bao'an District, Shenzhen, China

    Science.gov (United States)

    Li, Tianhong; Bai, Fengjiao; Han, Peng; Zhang, Yuanyan

    2016-11-01

    Urban sprawl is a major driving force that alters local and regional hydrology and increases non-point source pollution. Using the Bao'an District in Shenzhen, China, a typical rapid urbanization area, as the study area and land-use change maps from 1988 to 2014 that were obtained by remote sensing, the contributions of different land-use types to NPS pollutant production were assessed with a localized long-term hydrologic impact assessment (L-THIA) model. The results show that the non-point source pollution load changed significantly both in terms of magnitude and spatial distribution. The loads of chemical oxygen demand, total suspended substances, total nitrogen and total phosphorus were affected by the interactions between event mean concentration and the magnitude of changes in land-use acreages and the spatial distribution. From 1988 to 2014, the loads of chemical oxygen demand, suspended substances and total phosphorus showed clearly increasing trends with rates of 132.48 %, 32.52 % and 38.76 %, respectively, while the load of total nitrogen decreased by 71.52 %. The immigrant population ratio was selected as an indicator to represent the level of rapid urbanization and industrialization in the study area, and a comparison analysis of the indicator with the four non-point source loads demonstrated that the chemical oxygen demand, total phosphorus and total nitrogen loads are linearly related to the immigrant population ratio. The results provide useful information for environmental improvement and city management in the study area.

  1. Fireworks induced particle pollution: A spatio-temporal analysis

    Science.gov (United States)

    Kumar, M.; Singh, R. K.; Murari, V.; Singh, A. K.; Singh, R. S.; Banerjee, T.

    2016-11-01

    Diwali-specific firework induced particle pollution was measured in terms of aerosol mass loading, type, optical properties and vertical distribution. Entire nation exhibited an increase in particulate concentrations specifically in Indo-Gangetic Plain (IGP). Aerosol surface mass loading at middle IGP revealed an increase of 56-121% during festival days in comparison to their background concentrations. Space-borne measurements (Aqua and Terra-MODIS) typically identified IGP with moderate to high AOD (0.3-0.8) during pre-festive days which transmutes to very high AOD (0.4-1.8) during Diwali-day with accumulation of aerosol fine mode fractions (0.3-1.0). Most of the aerosol surface monitoring stations exhibited increase in PM2.5 especially on Diwali-day while PM10 exhibited increase on subsequent days. Elemental compositions strongly support K, Ba, Sr, Cd, S and P to be considered as firework tracers. The upper and middle IGP revealed dominance of absorbing aerosols (OMI-AI: 0.80-1.40) while CALIPSO altitude-orbit-cross-section profiles established the presence of polluted dust which eventually modified with association of smoke and polluted continental during extreme fireworks. Diwali-specific these observations have implications on associating fireworks induced particle pollution and human health while inclusion of these observations should improve regional air quality model.

  2. Degradation of isobutanal at high loading rates in a compost biofilter.

    Science.gov (United States)

    Sercu, Bram; Demeestere, Kristof; Baillieul, Hans; Van Langenhove, Herman; Verstraete, Willy

    2005-08-01

    Biofiltration has been increasingly used for cleaning waste gases, mostly containing low concentrations of odorous compounds. To expand the application area of this technology, the biofiltration of higher pollutant loading rates has to be investigated. This article focuses on the biodegradation of isobutanal (IBAL) in a compost biofilter (BF) at mass loading rates between 211 and 4123 g/m3/day (30-590 ppm(v)). At mass loading rates up to 785 g/m3/day, near 100% removal efficiencies could be obtained. However, after increasing the loading rate to 1500-1900 g/m3/ day, the degradation efficiency decreased to 62-98%. In addition, a pH decrease and production of isobutanol (IBOL) and isobutyric acid (IBAC) were observed. This is the first report showing that an aldehyde can act as electron donor as well as acceptor in a BF. To study the effects of pH, compost moisture content, and electron acceptor availability on the biofiltration of IBAL, IBOL, and IBAC, additional batch and continuous experiments were performed. A pH of 5.2 reduced the IBAL degradation rate and inhibited the IBOL degradation, although adaptation of the microorganisms to low pH was observed in the BFs. IBAC was not degraded in the batch experiments. High moisture content (51%) initially had no effect on the IBOL production, although it negatively affected the IBAL elimination increasingly during a 21-day time-course experiment. In batch experiments, the reduction of IBAL to IBOL did not decrease when the amount of available electron acceptors (oxygen or nitrate) was increased. The IBAL removal efficiency at higher loading rates was limited by a combination of nutrient limitation, pH decrease, and dehydration, and the importance of each limiting factor depended on the influent concentration.

  3. High-efficiency water-loaded microwave antenna in ultra-high-frequency band

    Science.gov (United States)

    Gong, Zilun; Bartone, Chris; Yang, Fuyi; Yao, Jie

    2018-03-01

    High-index dielectrics are widely used in microwave antennas to control the radiation characteristics. Liquid water, with a high dielectric index at microwave frequency, is an interesting material to achieving tunable functionalities. Here, we demonstrate a water-loaded microwave antenna system that has high loss-tolerance and wideband tunability enabled by fluidity. Our simulation and experimental results show that the resonance frequency can be effectively tuned by the size of loading water. Furthermore, the antenna systems with water loading can achieve high radiation efficiency (>90%) in the ultra-high-frequency (0.3-3 GHz) band. This work brings about opportunities in realistic tunable microwave antenna designs enabled by liquid.

  4. Application of static critical load models for acidity to high mountain lakes in Europe

    Czech Academy of Sciences Publication Activity Database

    Curtis, C. J.; Barbieri, A.; Camarero, L.; Gabathuler, M.; Galas, J.; Hanselmann, K.; Kopáček, Jiří; Mosello, R.; Nickus, U.; Rose, N.; Stuchlík, E.; Thies, H.; Ventura, M.; Wright, R.

    2002-01-01

    Roč. 2, č. 2 (2002), s. 115-126 ISSN 1567-7230 Grant - others:EU(XE) MOLAR ENV4-CT95-0007; EU(XE) Environment and Climate Programme Keywords : acid deposition * critical loads Subject RIV: DJ - Water Pollution ; Quality

  5. A Web-Based Tool to Interpolate Nitrogen Loading Using a Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Youn Shik Park

    2014-09-01

    Full Text Available Water quality data may not be collected at a high frequency, nor over the range of streamflow data. For instance, water quality data are often collected monthly, biweekly, or weekly, since collecting and analyzing water quality samples are costly compared to streamflow data. Regression models are often used to interpolate pollutant loads from measurements made intermittently. Web-based Load Interpolation Tool (LOADIN was developed to provide user-friendly interfaces and to allow use of streamflow and water quality data from U.S. Geological Survey (USGS via web access. LOADIN has a regression model assuming that instantaneous load is comprised of the pollutant load based on streamflow and the pollutant load variation within the period. The regression model has eight coefficients determined by a genetic algorithm with measured water quality data. LOADIN was applied to eleven water quality datasets from USGS gage stations located in Illinois, Indiana, Michigan, Minnesota, and Wisconsin states with drainage areas from 44 km2 to 1,847,170 km2. Measured loads were calculated by multiplying nitrogen data by streamflow data associated with measured nitrogen data. The estimated nitrogen loads and measured loads were evaluated using Nash-Sutcliffe Efficiency (NSE and coefficient of determination (R2. NSE ranged from 0.45 to 0.91, and R2 ranged from 0.51 to 0.91 for nitrogen load estimation.

  6. Characteristics of air pollutant dispersion around a high-rise building

    International Nuclear Information System (INIS)

    Zhang, Y.; Kwok, K.C.S.; Liu, X.-P.; Niu, J.-L.

    2015-01-01

    A numerical wind tunnel model was proposed. The computed results of the pollutant diffusion around a typical Hong Kong high-rise building model (at a linear scale of 1:30), were found to show a similar trend to the outcomes of self-conducted experimental measurements that the pathways of pollutant migration for windward and leeward pollutant emission are different. For the case with windward pollutant emission at the 3rd floor within a re-entry, the pollutant migrated downwards due to the downwash created by the wind. In contrast, for the case with leeward pollution emission, dispersion is dominated by intense turbulent mixing in the near wake and characterized by the upward migration of the pollutant in the leeward re-entry. The simulated results of haze-fog (HF) studies confirm that the pathway of pollutant migration is dominated by wind–structure interaction and buoyancy effect only plays a minor role in the dispersion process. - Highlights: • A self-developed numerical wind tunnel model was proposed. • Characteristics of air pollutant dispersion with windward/leeward emission were discussed. • Wind–structure interaction controls the air pollutant dispersion around the building. - The different characteristics of air pollutant dispersion around a high-rise building, for both cases of a dispersion source in either the windward face or leeward face, are dominated by wind–structure interaction, with buoyancy effect playing only a minor role

  7. Impacts of long-range transboundary air pollution. Report prepared within the framework of the Convention on Long-range Transboundary Air Pollution

    International Nuclear Information System (INIS)

    1992-01-01

    This eighth volume of the series of Air Pollution Studies, published under the auspices of the Executive Body for the Convention on Long-range Transboundary Air Pollution, contains the documents reviewed and approved for publication at the ninth session of the Executive Body held at Geneva from 18 to 22 November 1991. Part one is the Annual Review of Strategies and Policies for Air Pollution Abatement. Part two describes the critical load concept and the role of the best available technology and other approaches in air pollution abatement strategies. The report analyses the aim, elements and examples of the use of the receptor-oriented or effect-based critical load approach. It also evaluates the role of the source-oriented or technology-based approach as a supplement, rather than an alternative, to the critical load approach. The report contains a table with examples of national target loads for acidity or sulphur as well as preliminary European maps of critical loads of actual acidity, sulphur, present load computation of sulphur and the exceedance of the critical load of sulphur. Part three is an executive summary of the 1990 Forest Damage Survey in Europe, carried out under the International Co-operative Programme for Assessment and Monitoring of Air Pollution Effects on Forests. Part four is an executive summary of the interim report on cause/effect relationships in forest decline. Part five reviews recent research results on effects of acid deposition on atmospheric corrosion of materials

  8. The concept of target and critical loads

    International Nuclear Information System (INIS)

    Grigal, D.F.

    1991-09-01

    Target and critical loads were initially developed for assessment and control of acidic deposition, but are being considered for other air pollutants such as ozone and air-borne toxic compounds. These loads are based on thresholds, with damage assumed to occur above some defined level of deposition. Many of the historically proposed targets for acidic deposition were based on arbitrary interpretations of data. The concept of critical loads has recently separated from that of target loads. A critical load is the amount of pollutant deposition, determined by technical analysis, above which there is a specific deleterious ecological effect. A target load is the deposition, determined by political agreement, above which unacceptable ecological damage occurs; it may be greater than the critical load because of political or economic considerations, or less to conservatively account for uncertainty in the estimation of the critical load. Recent definitions of critical loads include recognition that each kind of ecosystem and effect may require a different load. Geographic regions contain a mosaic of aquatic and terrestrial resources. If precise knowledge leads to different critical loads for each system, then how is the regional target load established? For better or worse, target and critical loads are likely to be used to regulate air pollutants. The philosophy of their establishment as thresholds, their quantitative validity, and their application in regulation all require careful examination. 36 refs., 3 figs

  9. How uncertain is model-based prediction of copper loads in stormwater runoff?

    DEFF Research Database (Denmark)

    Lindblom, Erik Ulfson; Ahlman, S.; Mikkelsen, Peter Steen

    2007-01-01

    (runoff volumes and pollutant masses). We use the generalized likelihood uncertainty estimation (GLUE) methodology and generate posterior parameter distributions that result in model outputs encompassing a significant number of the highly variable measurements. Given the applied pollution accumulation......In this paper, we conduct a systematic analysis of the uncertainty related with estimating the total load of pollution (copper) from a separate stormwater drainage system, conditioned on a specific combination of input data, a dynamic conceptual pollutant accumulation-washout model and measurements...

  10. The role of forest in mitigating the impact of atmospheric dust pollution in a mixed landscape.

    Science.gov (United States)

    Santos, Artur; Pinho, Pedro; Munzi, Silvana; Botelho, Maria João; Palma-Oliveira, José Manuel; Branquinho, Cristina

    2017-05-01

    Atmospheric dust pollution, especially particulate matter below 2.5 μm, causes 3.3 million premature deaths per year worldwide. Although pollution sources are increasingly well known, the role of ecosystems in mitigating their impact is still poorly known. Our objective was to investigate the role of forests located in the surrounding of industrial and urban areas in reducing atmospheric dust pollution. This was tested using lichen transplants as biomonitors in a Mediterranean regional area with high levels of dry deposition. After a multivariate analysis, we have modeled the maximum pollution load expected for each site taking into consideration nearby pollutant sources. The difference between maximum expected pollution load and the observed values was explained by the deposition in nearby forests. Both the dust pollution and the ameliorating effect of forested areas were then mapped. The results showed that forest located nearby pollution sources plays an important role in reducing atmospheric dust pollution, highlighting their importance in the provision of the ecosystem service of air purification.

  11. Low cognitive load strengthens distractor interference while high load attenuates when cognitive load and distractor possess similar visual characteristics.

    Science.gov (United States)

    Minamoto, Takehiro; Shipstead, Zach; Osaka, Naoyuki; Engle, Randall W

    2015-07-01

    Studies on visual cognitive load have reported inconsistent effects of distractor interference when distractors have visual characteristic that are similar to the cognitive load. Some studies have shown that the cognitive load enhances distractor interference, while others reported an attenuating effect. We attribute these inconsistencies to the amount of cognitive load that a person is required to maintain. Lower amounts of cognitive load increase distractor interference by orienting attention toward visually similar distractors. Higher amounts of cognitive load attenuate distractor interference by depleting attentional resources needed to process distractors. In the present study, cognitive load consisted of faces (Experiments 1-3) or scenes (Experiment 2). Participants performed a selective attention task in which they ignored face distractors while judging a color of a target dot presented nearby, under differing amounts of load. Across these experiments distractor interference was greater in the low-load condition and smaller in the high-load condition when the content of the cognitive load had similar visual characteristic to the distractors. We also found that when a series of judgments needed to be made, the effect was apparent for the first trial but not for the second. We further tested an involvement of working memory capacity (WMC) in the load effect (Experiment 3). Interestingly, both high and low WMC groups received an equivalent effect of the cognitive load in the first distractor, suggesting these effects are fairly automatic.

  12. Performance of a 2-megawatt high voltage test load

    International Nuclear Information System (INIS)

    Horan, D.; Kustom, R.; Ferguson, M.

    1995-01-01

    A high-power, water-cooled resistive load which simulates the electrical load characteristics of a high-power klystron, capable of 2 megawatts dissipation at 95 kV DC, was built and installed at the Advanced Photon Source for use in load-testing high voltage power supplies. During this testing, the test load has logged approximately 35 hours of operation at power levels in excess of one mezawatt. Slight variations in the resistance of the load during operation indicate that leakage currents in the cooling water may be a significant factor affecting the performance of the load. Sufficient performance data have been collected to indicate that leakage current through the deionized (DI) water coolant shunts roughly 15 percent of the full-load current around the load resistor elements. The leakage current could cause deterioration of internal components of the load. The load pressure vessel was disassembled and inspected internally for any signs of significant wear and distress. Results of this inspection and possible modifications for improved performance will be discussed

  13. Cyanobacterial flora from polluted industrial effluents.

    Science.gov (United States)

    Parikh, Amit; Shah, Vishal; Madamwar, Datta

    2006-05-01

    Effluents originating from pesticides, agro-chemicals, textile dyes and dyestuffs industries are always associated with high turbidity, colour, nutrient load, and heavy metals, toxic and persistent compounds. But even with such an anthropogenic nature, these effluents contain dynamic cyanobacterial communities. Documentation of cyanobacterial cultures along the water channels of effluents discharged by above mentioned industries along the west coast of India and their relationship with water quality is reported in this study. Intensity of pollution was evaluated by physico-chemical analysis of water. Higher load of solids, carbon and nutrients were found to be persistent throughout the analysis. Sediment and water samples were found to be colored in nature. Cyanobacterial community structure was found to be influenced by the anthropogenic pollution. 40 different cyanobacterial species were recorded from 14 genera of 5 families and an elevated occurrence of Phormidium, Oscillatoria and Chroococcus genera was observed in all the sampling sites.

  14. [Pollution load and the first flush effect of BOD5 and COD in urban runoff of Wenzhou City].

    Science.gov (United States)

    Wang, Jun; Bi, Chun-juan; Chen, Zhen-lou; Zhou, Dong

    2013-05-01

    Four typical rainfalls were monitored in two different research areas of Wenzhou Municipality. Concentrations of BOD5 and COD in six different urban runoffs were measured. In addition the event mean concentration (EMC), M (V) curve and BOD5/COD of pollutant were calculated. The results showed that concentrations of BOD5 and COD in different urban runoffs of Wenzhou ranged from ND to 69.21 mg x L(-1) and ND to 636 mg x L(-1). Concentrations of BOD5 and COD in different urban runoffs were decreasing over time, so it is greatly significant to manage the initial runoff for reducing organic pollution. Judged by EMC of BOD5 and COD in these five rainfalls, concentrations of pollutant in some urban runoffs were out of the integrated wastewater discharge standard. If these runoffs flowed into river, it would cause environmental pressure to the next level receiving water bodies. According to the M (V) curve, the first flush effect of COD in most urban runoffs was common; while the first flush effect of BOD5 was same as that of COD. The result also showed that organic pollution was serious at the beginning of runoff. The underlying surface type could affect the concentration of BOD5 and COD in urban runoff. While the results of BOD5/COD also suggested that biodegradation was considered as one of the effective ways to decrease the pollution load of organics in urban runoff, and the best management plans (BMPs) should be selected for various urban runoff types for the treatment of organic pollution.

  15. Long term remediation of highly polluted acid mine drainage: A sustainable approach to restore the environmental quality of the Odiel river basin

    International Nuclear Information System (INIS)

    Caraballo, Manuel A.; Macias, Francisco; Roetting, Tobias S.; Nieto, Jose Miguel; Ayora, Carlos

    2011-01-01

    During 20 months of proper operation the full scale passive treatment in Mina Esperanza (SW Spain) produced around 100 mg/L of ferric iron in the aeration cascades, removing an average net acidity up to 1500 mg/L as CaCO 3 and not having any significant clogging problem. Complete Al, As, Cd, Cr, Cu, Ti and V removal from the water was accomplished through almost the entire operation time while Fe removal ranged between 170 and 620 mg/L. The system operated at a mean inflow rate of 43 m 3 /day achieving an acid load reduction of 597 g.(m 2 day) -1 , more than 10 times higher than the generally accepted 40 g.(m 2 day) -1 value commonly used as a passive treatment system designing criteria. The high performance achieved by the passive treatment system at Mina Esperanza demonstrates that this innovative treatment design is a simple, efficient and long lasting remediation option to treat highly polluted acid mine drainage. - Highlights: → Novel reactive mixture enable 20 month of high hydraulic conductivity. → Acid load reduction improved 10 times comparing to vertical flow wetland. → High biotic and abiotic iron oxidation and removal. → Complete Al, As, Cd, Cr, Cu, Ti and V water removal. - A high permeable alkaline reactive substrate offers a sustainable option to remediate severely polluted acid mine drainage in the Odiel basin

  16. Mass concentration coupled with mass loading rate for evaluating PM_2_._5 pollution status in the atmosphere: A case study based on dairy barns

    International Nuclear Information System (INIS)

    Joo, HungSoo; Park, Kihong; Lee, Kwangyul; Ndegwa, Pius M.

    2015-01-01

    This study investigated particulate matter (PM) loading rates and concentrations in ambient air from naturally ventilated dairy barns and also the influences of pertinent meteorological factors, traffic, and animal activities on mass loading rates and mass concentrations. Generally, relationships between PM_2_._5 concentration and these parameters were significantly poorer than those between the PM loading rate and the same parameters. Although ambient air PM_2_._5 loading rates correlated well with PM_2_._5 emission rates, ambient air PM_2_._5 concentrations correlated poorly with PM_2_._5 concentrations in the barns. A comprehensive assessment of PM_2_._5 pollution in ambient air, therefore, requires both mass concentrations and mass loading rates. Emissions of PM_2_._5 correlated strongly and positively with wind speed, temperature, and solar radiation (R"2 = 0.84 to 0.99) and strongly but negatively with relative humidity (R"2 = 0.93). Animal activity exhibited only moderate effect on PM_2_._5 emissions, while traffic activity did not significantly affect PM_2_._5 emissions. - Highlights: • Sink PM_2_._5 loading rates correlate well with source PM_2_._5 emission rates. • Sink PM_2_._5 concentrations correlate poorly with source PM_2_._5 concentrations. • Mass loading rate complements mass concentration in appraising sink PM_2_._5 status. • PM_2_._5 emissions is dependent on wind speed, temp, solar strength, and RH. • Cow traffic activity affects PM_2_._5 emissions, while traffic activity does not. - Both PM mass loading rate and concentrations are required for comprehensive assessment of pollution potential of PM released into the atmosphere.

  17. An urban observatory for quantifying phosphorus and suspended solid loads in combined natural and stormwater conveyances.

    Science.gov (United States)

    Melcher, Anthony A; Horsburgh, Jeffery S

    2017-06-01

    Water quality in urban streams and stormwater systems is highly dynamic, both spatially and temporally, and can change drastically during storm events. Infrequent grab samples commonly collected for estimating pollutant loadings are insufficient to characterize water quality in many urban water systems. In situ water quality measurements are being used as surrogates for continuous pollutant load estimates; however, relatively few studies have tested the validity of surrogate indicators in urban stormwater conveyances. In this paper, we describe an observatory aimed at demonstrating the infrastructure required for surrogate monitoring in urban water systems and for capturing the dynamic behavior of stormwater-driven pollutant loads. We describe the instrumentation of multiple, autonomous water quality and quantity monitoring sites within an urban observatory. We also describe smart and adaptive sampling procedures implemented to improve data collection for developing surrogate relationships and for capturing the temporal and spatial variability of pollutant loading events in urban watersheds. Results show that the observatory is able to capture short-duration storm events within multiple catchments and, through inter-site communication, sampling efforts can be synchronized across multiple monitoring sites.

  18. Water quality assessment of highly polluted rivers in a semi-arid Mediterranean zone Oued Fez and Sebou River (Morocco)

    Science.gov (United States)

    Perrin, J. L.; Raïs, N.; Chahinian, N.; Moulin, P.; Ijjaali, M.

    2014-03-01

    Oued Fez (one of the Sebou River tributaries - Morocco) allowed us to study and quantify the effect of the lack of wastewater treatment on surface water quality in semi-arid hydrological context. The analysis is based on field data collected from June 2009 to December 2011. Concentration and load patterns of nitrogen, phosphorus and chromium (used in the processing of leather) are compared in stable hydrological conditions during low flow and high flow periods in an eight-location sampling network. The Oued Fez and the Sebou River are characterised by severe pollution downstream from the city of Fez, particularly TN (mainly NH4 and Norg), TP (mainly Ppart) and TCr. The most polluted sites are those directly under the influence of domestic and industrial waste water inputs, particularly tannery effluents. Obviously, the concentrations measured at these locations are above all environmental quality standards. Pollutant loads are very heavy in the Sebou River and can contaminate the river course for kilometres. Moreover, as the water of the Sebou River is used for the irrigation of vegetables, serious problems of public health could arise. A better understanding of contaminant dynamics and self-purifying processes in these rivers will help implement actions and steps aimed at improving water quality in the Sebou River, which is the primary water supply source in Morocco and is used for agricultural and industrials purposes as well as for drinking water.

  19. Biogas from organically high polluted industrial waste waters

    Energy Technology Data Exchange (ETDEWEB)

    Sixt, H

    1985-06-01

    Organically high polluted waste water sets special claims for an economical purification and the process treatment. Up to now these waste waters are being purified by anaerobic processes with simultaneous biogas generation. The fourstep anaerobic degradation is influenced by a lot of important parameters. Extensive researchers in the field of anaerobic microbiology has improved the knowledge of the fundamental principles. Parallel the reactor technology is developed worldwide. In general it seems that the fixed-film-reactor with immobilized bacteria has the best future to purify organically high polluted industrial waste water with short retention times under stable operation conditions.

  20. Stochastic sensitivity analysis of nitrogen pollution to climate change in a river basin with complex pollution sources.

    Science.gov (United States)

    Yang, Xiaoying; Tan, Lit; He, Ruimin; Fu, Guangtao; Ye, Jinyin; Liu, Qun; Wang, Guoqing

    2017-12-01

    It is increasingly recognized that climate change could impose both direct and indirect impacts on the quality of the water environment. Previous studies have mostly concentrated on evaluating the impacts of climate change on non-point source pollution in agricultural watersheds. Few studies have assessed the impacts of climate change on the water quality of river basins with complex point and non-point pollution sources. In view of the gap, this paper aims to establish a framework for stochastic assessment of the sensitivity of water quality to future climate change in a river basin with complex pollution sources. A sub-daily soil and water assessment tool (SWAT) model was developed to simulate the discharge, transport, and transformation of nitrogen from multiple point and non-point pollution sources in the upper Huai River basin of China. A weather generator was used to produce 50 years of synthetic daily weather data series for all 25 combinations of precipitation (changes by - 10, 0, 10, 20, and 30%) and temperature change (increases by 0, 1, 2, 3, and 4 °C) scenarios. The generated daily rainfall series was disaggregated into the hourly scale and then used to drive the sub-daily SWAT model to simulate the nitrogen cycle under different climate change scenarios. Our results in the study region have indicated that (1) both total nitrogen (TN) loads and concentrations are insensitive to temperature change; (2) TN loads are highly sensitive to precipitation change, while TN concentrations are moderately sensitive; (3) the impacts of climate change on TN concentrations are more spatiotemporally variable than its impacts on TN loads; and (4) wide distributions of TN loads and TN concentrations under individual climate change scenario illustrate the important role of climatic variability in affecting water quality conditions. In summary, the large variability in SWAT simulation results within and between each climate change scenario highlights the uncertainty of

  1. A Study on management plan of pollutants in agricultural region

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jee Yong; Shin, Eun Sung [Korea Environment Institute, Seoul (Korea)

    1998-12-01

    The water environment in fishing and agricultural region in Korea is getting poor. For improving the quality of water, it is essential to manage pollutants by agricultural activities. For an efficient water quality control, a reasonable examination of the amount of agricultural pollutant load, and the development of efficient technology and policy for reducing the amount of pollution load are required. The management of pollutants considering agricultural characteristics was derived in this study and the amount of discharged pollutants by land usage in agricultural region was researched. 43 refs., 17 figs., 61 tabs.

  2. Total pollution effect of urban surface runoff.

    Science.gov (United States)

    Luo, Hongbing; Luo, Lin; Huang, Gu; Liu, Ping; Li, Jingxian; Hu, Sheng; Wang, Fuxiang; Xu, Rui; Huang, Xiaoxue

    2009-01-01

    For pollution research with regard to urban surface runoff, most sampling strategies to date have focused on differences in land usage. With single land-use sampling, total surface runoff pollution effect cannot be evaluated unless every land usage spot is monitored. Through a new sampling strategy known as mixed stormwater sampling for a street community at discharge outlet adjacent to river, this study assessed the total urban surface runoff pollution effect caused by a variety of land uses and the pollutants washed off from the rain pipe system in the Futian River watershed in Shenzhen City of China. The water quality monitoring indices were COD (chemical oxygen demand), TSS (total suspend solid), TP (total phosphorus), TN (total nitrogen) and BOD (biochemical oxygen demand). The sums of total pollution loads discharged into the river for the four indices of COD, TSS, TN, and TP over all seven rainfall events were very different. The mathematical model for simulating total pollution loads was established from discharge outlet mixed stormwater sampling of total pollution loads on the basis of four parameters: rainfall intensity, total land area, impervious land area, and pervious land area. In order to treat surface runoff pollution, the values of MFF30 (mass first flush ratio) and FF30 (first 30% of runoff volume) can be considered as split-flow control criteria to obtain more effective and economical design of structural BMPs (best management practices) facilities.

  3. An Architecture Offering Mobile Pollution Sensing with High Spatial Resolution

    Directory of Open Access Journals (Sweden)

    Oscar Alvear

    2016-01-01

    Full Text Available Mobile sensing is becoming the best option to monitor our environment due to its ease of use, high flexibility, and low price. In this paper, we present a mobile sensing architecture able to monitor different pollutants using low-end sensors. Although the proposed solution can be deployed everywhere, it becomes especially meaningful in crowded cities where pollution values are often high, being of great concern to both population and authorities. Our architecture is composed of three different modules: a mobile sensor for monitoring environment pollutants, an Android-based device for transferring the gathered data to a central server, and a central processing server for analyzing the pollution distribution. Moreover, we analyze different issues related to the monitoring process: (i filtering captured data to reduce the variability of consecutive measurements; (ii converting the sensor output to actual pollution levels; (iii reducing the temporal variations produced by mobile sensing process; and (iv applying interpolation techniques for creating detailed pollution maps. In addition, we study the best strategy to use mobile sensors by first determining the influence of sensor orientation on the captured values and then analyzing the influence of time and space sampling in the interpolation process.

  4. Long term remediation of highly polluted acid mine drainage: A sustainable approach to restore the environmental quality of the Odiel river basin

    Energy Technology Data Exchange (ETDEWEB)

    Caraballo, Manuel A., E-mail: manuel.caraballo@dgeo.uhu.es [Geology Department, University of Huelva, Avenida 3 de Marzo s/n, Campus ' El Carmen' , E-21071 Huelva (Spain); Macias, Francisco [Geology Department, University of Huelva, Avenida 3 de Marzo s/n, Campus ' El Carmen' , E-21071 Huelva (Spain); Roetting, Tobias S. [Technical University of Catalonia (UPC), Hydrogeology Group, E-08034 Barcelona (Spain); Nieto, Jose Miguel [Geology Department, University of Huelva, Avenida 3 de Marzo s/n, Campus ' El Carmen' , E-21071 Huelva (Spain); Ayora, Carlos [Institute of Environmental Assessment and Water Research, IDAEA - CSIC, Jordi Girona 18, 08034 Barcelona (Spain)

    2011-12-15

    During 20 months of proper operation the full scale passive treatment in Mina Esperanza (SW Spain) produced around 100 mg/L of ferric iron in the aeration cascades, removing an average net acidity up to 1500 mg/L as CaCO{sub 3} and not having any significant clogging problem. Complete Al, As, Cd, Cr, Cu, Ti and V removal from the water was accomplished through almost the entire operation time while Fe removal ranged between 170 and 620 mg/L. The system operated at a mean inflow rate of 43 m{sup 3}/day achieving an acid load reduction of 597 g.(m{sup 2} day){sup -1}, more than 10 times higher than the generally accepted 40 g.(m{sup 2} day){sup -1} value commonly used as a passive treatment system designing criteria. The high performance achieved by the passive treatment system at Mina Esperanza demonstrates that this innovative treatment design is a simple, efficient and long lasting remediation option to treat highly polluted acid mine drainage. - Highlights: > Novel reactive mixture enable 20 month of high hydraulic conductivity. > Acid load reduction improved 10 times comparing to vertical flow wetland. > High biotic and abiotic iron oxidation and removal. > Complete Al, As, Cd, Cr, Cu, Ti and V water removal. - A high permeable alkaline reactive substrate offers a sustainable option to remediate severely polluted acid mine drainage in the Odiel basin

  5. Noise Pollution and Health Effects

    Directory of Open Access Journals (Sweden)

    Geravandi

    2015-01-01

    Full Text Available Background Noise pollution is of particular importance due to the physical and psychological effects on humans. Noise is a stressor that affects the autonomic nervous system and the endocrine system. Noise is also a threat to marine and terrestrial ecosystems. Health risks from noise are correlated with road traffic. In other words, noise health effects are the health consequences of elevated sound levels. Objectives This study aims to determine the effect of noise pollution (near roadways on health issues in Ahvaz, Iran. Materials and Methods In this cross-sectional study, equivalent sound pressure level were measured by sound level meters TES-1353 in 75 locations around 4 roadways, which had a high load of traffic in Ahvaz City during day time. During the study, 820 measurements were recorded at measuring stations, for 7 days per week with 1-hour interval between each measurement. Statistical analysis was carried out by SPSS software. Results According to the research findings, the equivalent sound pressure levels in all stations were 76.28 ± 3.12 dB (Mean ± SD. According to sound measurements and the survey questionnaire, noise pollution is higher than EPA (US Environmental Protection Agency and Iran standard level. Based on result of this study the worst noise health effects were the nervousness and sleep quality during 2012. Conclusions According to the results of this study, with increasing load of traffic, there is an increasing need for proper consideration plans to control noise pollution and prevent its effects.

  6. Variable load failure mechanism for high-speed load sensing electro-hydrostatic actuator pump of aircraft

    Directory of Open Access Journals (Sweden)

    Cun SHI

    2018-05-01

    Full Text Available This paper presents a novel transient lubrication model for the analysis of the variable load failure mechanism of high-speed pump used in Load Sensing Electro-Hydrostatic Actuator (LS-EHA. Focusing on the slipper/swashplate pair partial abrasion, which is considered as the dominant failure mode in the high-speed condition, slipper dynamic models are established. A forth sliding motion of the slipper on the swashplate surface is presented under the fact that the slipper center of mass will rotate around the center of piston ball when the swashplate angle is dynamically adjusted. Besides, extra inertial tilting moments will be produced for the slipper based on the theorem on translation of force, which will increase rapidly when LS-EHA pump operates under high-speed condition. Then, a dynamic lubricating model coupling with fluid film thickness field, temperature field and pressure field is proposed. The deformation effects caused by thermal deflection and hydrostatic pressure are considered. A numerical simulation model is established to validate the effectiveness and accuracy of the proposed model. Finally, based on the load spectrum of aircraft flight profile, the variable load conditions and the oil film characteristics are analyzed, and series of variable load rules of oil film thickness with variable speed/variable pressure/variable displacement are concluded. Keywords: Coupling lubrication model, Electro-Hydrostatic Actuator (EHA, High-speed pump, Partial abrasion, Slipper pair, Variable load

  7. Activities of everyday life with high spinal loads.

    Directory of Open Access Journals (Sweden)

    Antonius Rohlmann

    Full Text Available Activities with high spinal loads should be avoided by patients with back problems. Awareness about these activities and knowledge of the associated loads are important for the proper design and pre-clinical testing of spinal implants. The loads on an instrumented vertebral body replacement have been telemetrically measured for approximately 1000 combinations of activities and parameters in 5 patients over a period up to 65 months postoperatively. A database containing, among others, extreme values for load components in more than 13,500 datasets was searched for 10 activities that cause the highest resultant force, bending moment, torsional moment, or shear force in an anatomical direction. The following activities caused high resultant forces: lifting a weight from the ground, forward elevation of straight arms with a weight in hands, moving a weight laterally in front of the body with hanging arms, changing the body position, staircase walking, tying shoes, and upper body flexion. All activities have in common that the center of mass of the upper body was moved anteriorly. Forces up to 1650 N were measured for these activities of daily life. However, there was a large intra- and inter-individual variation in the implant loads for the various activities depending on how exercises were performed. Measured shear forces were usually higher in the posterior direction than in the anterior direction. Activities with high resultant forces usually caused high values of other load components.

  8. Enhanced air pollution via aerosol-boundary layer feedback in China.

    Science.gov (United States)

    Petäjä, T; Järvi, L; Kerminen, V-M; Ding, A J; Sun, J N; Nie, W; Kujansuu, J; Virkkula, A; Yang, X-Q; Fu, C B; Zilitinkevich, S; Kulmala, M

    2016-01-12

    Severe air pollution episodes have been frequent in China during the recent years. While high emissions are the primary reason for increasing pollutant concentrations, the ultimate cause for the most severe pollution episodes has remained unclear. Here we show that a high concentration of particulate matter (PM) will enhance the stability of an urban boundary layer, which in turn decreases the boundary layer height and consequently cause further increases in PM concentrations. We estimate the strength of this positive feedback mechanism by combining a new theoretical framework with ambient observations. We show that the feedback remains moderate at fine PM concentrations lower than about 200 μg m(-3), but that it becomes increasingly effective at higher PM loadings resulting from the combined effect of high surface PM emissions and massive secondary PM production within the boundary layer. Our analysis explains why air pollution episodes are particularly serious and severe in megacities and during the days when synoptic weather conditions stay constant.

  9. First flush of storm runoff pollution from an urban catchment in China.

    Science.gov (United States)

    Li, Li-Qing; Yin, Cheng-Qing; He, Qing-Ci; Kong, Ling-Li

    2007-01-01

    Storm runoff pollution process was investigated in an urban catchment with an area of 1.3 km2 in Wuhan City of China. The results indicate that the pollutant concentration peaks preceded the flow peaks in all of 8 monitored storm events. The intervals between pollution peak and flow peak were shorter in the rain events with higher intensity in the initial period than those with lower intensity. The fractions of pollution load transported by the first 30% of runoff volume (FF30) were 52.2%-72.1% for total suspended solids (TSS), 53.0%-65.3% for chemical oxygen demand (COD), 40.4%-50.6% for total nitrogen (TN), and 45.8%-63.2% for total phosphorus (TP), respectively. Runoff pollution was positively related to non-raining days before the rainfall. Intercepting the first 30% of runoff volume can remove 62.4% of TSS load, 59.4% of COD load, 46.8% of TN load, and 54.1% of TP load, respectively, according to all the storm events. It is suggested that controlling the first flush is a critical measure in reduction of urban stormwater pollution.

  10. Application of subsurface wastewater infiltration system to on-site treatment of domestic sewage under high hydraulic loading rate

    Directory of Open Access Journals (Sweden)

    Ying-hua Li

    2015-01-01

    Full Text Available In order to enhance the hydraulic loading rate (HLR of a subsurface wastewater infiltration system (SWIS used in treating domestic sewage, the intermittent operation mode was employed in the SWIS. The results show that the intermittent operation mode contributes to the improvement of the HLR and the pollutant removal rate. When the wetting-drying ratio (RWD was 1.0, the pollutant removal rate increased by (13.6 ± 0.3% for NH3-N, (20.7 ± 1.1% for TN, (18.6 ± 0.4% for TP, (12.2 ± 0.5% for BOD, (10.1 ± 0.3% for COD, and (36.2 ± 1.2% for SS, compared with pollutant removal rates under the continuous operation mode. The pollutant removal rate declined with the increase of the HLR. The effluent quality met The Reuse of Urban Recycling Water – Water Quality Standard for Scenic Environment Use (GB/T 18921-2002 even when the HLR was as high as 10 cm/d. Hydraulic conductivity, oxidation reduction potential (ORP, the quantity of nitrifying bacteria, and the pollutant removal rate of NH3-N increased with the decrease of the RWD. For the pollutant removal rates of TP, BOD, and COD, there were no significant difference (p < 0.05 under different RWDs. The suggested RWD was 1.0. Relative contribution of the pretreatment and SWIS to the pollutant removal was examined, and more than 80% removal of NH3-N, TN, TP, COD, and BOD occurred in the SWIS.

  11. Soil carbon and nitrogen budget in Scots pine (Pinus sylvestris L.) stands along an air pollution gradient in eastern Germany

    International Nuclear Information System (INIS)

    Fischer, T.; Bergmann, C.; Huettl, R.F.

    1995-01-01

    Litterfall, bio- and necromass of the forest floor vegetation, decomposition of recent organic material, soil respiration and humus stocks were examined in 3 Scots pine stands along an air pollution gradient in eastern Germany. One site, Rosea, received heavy deposition loads from chemical industries and brown coal fired power plants. The site Taura received moderate air pollution due to lower deposition of coarse and calcium rich dust particles; the third site, Neuglobsow was afforested and represents a low polluted control site. High nitrogen loads and increased pH value due to Ca deposition caused shifts in the vegetation structure, and higher biomass production of the forest floor vegetation, whereas needle litter production was not impacted. Simultaneously, decomposition rates of the recently harvested forest floor vegetation decreased with increasing pollutant loads, but needle litter and soil organic matter decomposition rates did not differ between the sites. Consequently, soil carbon and nitrogen stocks increased with increasing pollutant input. 19 refs., 5 figs., 1 tab

  12. [Analysis on nitrogen and phosphorus loading of non-point sources in Shiqiao river watershed based on L-THIA model].

    Science.gov (United States)

    Li, Kai; Zeng, Fan-Tang; Fang, Huai-Yang; Lin, Shu

    2013-11-01

    Based on the Long-term Hydrological Impact Assessment (L-THIA) model, the effect of land use and rainfall change on nitrogen and phosphorus loading of non-point sources in Shiqiao river watershed was analyzed. The parameters in L-THIA model were revised according to the data recorded in the scene of runoff plots, which were set up in the watershed. The results showed that the distribution of areas with high pollution load was mainly concentrated in agricultural land and urban land. Agricultural land was the biggest contributor to nitrogen and phosphorus load. From 1995 to 2010, the load of major pollutants, namely TN and TP, showed an obviously increasing trend with increase rates of 17.91% and 25.30%, respectively. With the urbanization in the watershed, urban land increased rapidly and its area proportion reached 43.94%. The contribution of urban land to nitrogen and phosphorus load was over 40% in 2010. This was the main reason why pollution load still increased obviously while the agricultural land decreased greatly in the past 15 years. The rainfall occurred in the watershed was mainly concentrated in the flood season, so the nitrogen and phosphorus load of the flood season was far higher than that of the non-flood season and the proportion accounting for the whole year was over 85%. Pearson regression analysis between pollution load and the frequency of different patterns of rainfall demonstrated that rainfall exceeding 20 mm in a day was the main rainfall type causing non-point source pollution.

  13. Air Quality Assessment of Faisalabad and Gujranwala Cities of Pakistan: Application of Pollution Indices

    International Nuclear Information System (INIS)

    Faiz, Y.; Waheed, S.; Siddique, N.

    2015-01-01

    Urban air quality of industrial cities of Pakistan, namely Gujranwala and Faisalabad was assessed in terms of pollution level indicators such as pollution load index (PLI), geo-accumulation index (I/sub geo/), pollution index (PI) and integrated pollution index (IPI). It was found that both cities have elevated metal concentration indicating heavy to extreme contamination for most of the sites. Local anthropogenic activities and elevated geo-accumulation indices for different suite of elements were used to indicate possible pollutant sources in these two industrial cities to be traffic derived emissions, suspended soil, road dust, construction materials, fossil fuel and industrial emissions, tanneries, chrome plating units and metal smelters. Comparison of the pollution indices shows that Ba, Br, Ca, Cd, Na, Pb, Sb and Zn have mean PLI, I/sub geo/, PI and IPI for both cities which are in the highly polluted category. Cu, La, Sc, V and Zr have pollution indices corresponding to high or extreme levels in Faisalabad only while Cr and Ti are highly polluting only in Gujranwala. In Faisalabad and Gujranwala it was found that 91.43% and 85.29% respectively of the PI data occurs in high level of pollution implying that to some extent Faisalabad is more polluted as compared to Gujranwala. (author)

  14. Water Quality Trading when Nonpoint Pollution Loads are Stochastic

    OpenAIRE

    Ghosh, Gaurav; Shortle, James

    2009-01-01

    We compare two tradable permit markets in their ability to meet a stated environmental target at least cost when some polluters have stochastic and non-measurable emissions. The environmental target is of the safety-first type, which requires probabilistic emissions control. One market is built around the trading ratio, which defines the substitution rate between stochastic and deterministic pollution, and is modeled on existing markets for water quality trading. The other market is built aro...

  15. Air pollution exposure, cause-specific deaths and hospitalizations in a highly polluted Italian region.

    Science.gov (United States)

    Carugno, Michele; Consonni, Dario; Randi, Giorgia; Catelan, Dolores; Grisotto, Laura; Bertazzi, Pier Alberto; Biggeri, Annibale; Baccini, Michela

    2016-05-01

    The Lombardy region in northern Italy ranks among the most air polluted areas of Europe. Previous studies showed air pollution short-term effects on all-cause mortality. We examine here the effects of particulate matter with aerodynamic diameter ≤10µm (PM10) and nitrogen dioxide (NO2) exposure on deaths and hospitalizations from specific causes, including cardiac, cerebrovascular and respiratory diseases. We considered air pollution, mortality and hospitalization data for a non-opportunistic sample of 18 highly polluted and most densely populated areas of the region in the years 2003-2006. We obtained area-specific effect estimates for PM10 and NO2 from a Poisson regression model on the daily number of total deaths or cause-specific hospitalizations and then combined them in a Bayesian random-effects meta-analysis. For cause-specific mortality, we applied a case-crossover analysis. Age- and season-specific analyses were also performed. Effect estimates were expressed as percent variation in mortality or hospitalizations associated with a 10µg/m(3) increase in PM10 or NO2 concentration. Natural mortality was positively associated with both pollutants (0.30%, 90% Credibility Interval [CrI]: -0.31; 0.78 for PM10; 0.70%, 90%CrI: 0.10; 1.27 for NO2). Cardiovascular deaths showed a higher percent variation in association with NO2 (1.12%, 90% Confidence Interval [CI]: 0.14; 2.11), while the percent variation for respiratory mortality was highest in association with PM10 (1.64%, 90%CI: 0.35; 2.93). The effect of both pollutants was more evident in the summer season. Air pollution was also associated to hospitalizations, the highest variations being 0.77% (90%CrI: 0.22; 1.43) for PM10 and respiratory diseases, and 1.70% (90%CrI: 0.39; 2.84) for NO2 and cerebrovascular diseases. The effect of PM10 on respiratory hospital admissions appeared to increase with age. For both pollutants, effects on cerebrovascular hospitalizations were more evident in subjects aged less than

  16. [Watershed water environment pollution models and their applications: a review].

    Science.gov (United States)

    Zhu, Yao; Liang, Zhi-Wei; Li, Wei; Yang, Yi; Yang, Mu-Yi; Mao, Wei; Xu, Han-Li; Wu, Wei-Xiang

    2013-10-01

    Watershed water environment pollution model is the important tool for studying watershed environmental problems. Through the quantitative description of the complicated pollution processes of whole watershed system and its parts, the model can identify the main sources and migration pathways of pollutants, estimate the pollutant loadings, and evaluate their impacts on water environment, providing a basis for watershed planning and management. This paper reviewed the watershed water environment models widely applied at home and abroad, with the focuses on the models of pollutants loading (GWLF and PLOAD), water quality of received water bodies (QUAL2E and WASP), and the watershed models integrated pollutant loadings and water quality (HSPF, SWAT, AGNPS, AnnAGNPS, and SWMM), and introduced the structures, principles, and main characteristics as well as the limitations in practical applications of these models. The other models of water quality (CE-QUAL-W2, EFDC, and AQUATOX) and watershed models (GLEAMS and MIKE SHE) were also briefly introduced. Through the case analysis on the applications of single model and integrated models, the development trend and application prospect of the watershed water environment pollution models were discussed.

  17. High loading uranium plate

    International Nuclear Information System (INIS)

    Wiencek, T.C.; Domagala, R.F.; Thresh, H.R.

    1990-01-01

    Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pari of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat hiving a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process

  18. Part-load performance of a high temperature Kalina cycle

    International Nuclear Information System (INIS)

    Modi, Anish; Andreasen, Jesper Graa; Kærn, Martin Ryhl; Haglind, Fredrik

    2015-01-01

    Highlights: • Detailed algorithm to solve high temperature Kalina cycle in part load. • A central receiver concentrating solar power plant with direct vapour generation considered as case study. • Part-load performance curves and fitted equations presented. - Abstract: The Kalina cycle has recently seen increased interest as an alternative to the conventional steam Rankine cycle. The cycle has been studied for use with both low and high temperature applications such as geothermal power plants, ocean thermal energy conversion, waste heat recovery, gas turbine bottoming cycle, and solar power plants. The high temperature cycle layouts are inherently more complex than the low temperature layouts due to the presence of a distillation-condensation subsystem, three pressure levels, and several heat exchangers. This paper presents a detailed approach to solve the Kalina cycle in part-load operating conditions for high temperature (a turbine inlet temperature of 500 °C) and high pressure (100 bar) applications. A central receiver concentrating solar power plant with direct vapour generation is considered as a case study where the part-load conditions are simulated by changing the solar heat input to the receiver. Compared with the steam Rankine cycle, the Kalina cycle has an additional degree of freedom in terms of the ammonia mass fraction which can be varied in order to maximize the part-load efficiency of the cycle. The results include the part-load curves for various turbine inlet ammonia mass fractions and the fitted equations for these curves.

  19. Loading capacities and failure modes of various reinforced concrete slabs subjected to high-speed loading

    International Nuclear Information System (INIS)

    Saito, H.; Imamura, A.; Takeuchi, M.; Okamoto, S.; Kasai, Y.; Tsubota, H.; Yoshimura, M.

    1993-01-01

    The objective of this study was to clarify experimentally and analytically the loading capacities, deformations and failure modes of various types of reinforced concrete structures subjected to loads applied at various loading rates. Flat slabs, slabs with beams and cylindrical walls were tested under static, low-speed and high-speed loading. Analysis was applied to estimate the test results by the finite element method using a layered shell element. The analysis closely simulated the experimental results until punching shear failure occurred. (author)

  20. Load estimation and assessment of land-based pollution for Quanzhou Bay and their relevance to the Total Quantity Control of Pollutants Discharged into the Sea (TQCPS) Program in China

    Science.gov (United States)

    Zhao, W. L.; Yang, S. Y.; Wang, J.; Xiao, J. M.; Lu, X. X.; Lin, J.; Huang, P.; Cai, M. G.

    2015-12-01

    The Total Quantity Control of Pollutants Discharged into the Sea (TQCPS) Program belonged to the Public Science and Technology Research Funds Projects of Ocean in China, launched in 2008. As one of the most important and typical demonstration cases of the TQCPS Program, a full investigation of the land-based pollutions discharges around Quanzhou Bay, China developed the total input for three main environmental factors (NH3-N, TP, COD) which were estimated and quantified in 2008 and 2012, respectively. Combined with the trend of seawater quality changes in Quanzhou Bay in the same periods, the effects of the program's implementation were then evaluated. On the whole, by using the basic survey data and export coefficient method, the total amounts of NH3-N, TP and COD discharged into the bay were estimated to be approximately 888.3, 130.6 and 14527.4 t/a in 2008, and 1518.6, 558.8 and 19986.7 t/a in 2012, respectively, where the percentage of the discharge from domestic sources (46.5% in 2008 and 45.2% in 2012) was generally higher than that from the other sources. Based on the characteristic of geography and administrative division, the land areas around the bay were divided into three parts: the south coast region (SCR), the west coast region (WCR), and the north coast region (NCR). The SCR and WCR accounted for 59.2 and 35.4% of the COD loads, and 49.2 and 48.0% of NH3-N loads in 2008. The NCR contributed less of the industrial pollution, but most to domestic pollution (54.1%), followed by 26.2% in the SCR in 2012. The contributions of the discharge from different land areas to the pollution of Quanzhou Bay were found to be differed in 2008 and 2012. Due to the difference in the levels of the economic development among these three areas, the discharge of pollutants from the north coast was much lower than that from the other two parts in 2008; however, following our suggestion of the moderation and optimization of the industrial distribution and the sewage

  1. Optimal design of high-speed loading spindle based on ABAQUS

    Science.gov (United States)

    Yang, Xudong; Dong, Yu; Ge, Qingkuan; Yang, Hai

    2017-12-01

    The three-dimensional model of high-speed loading spindle is established by using ABAQUS’s modeling module. A finite element analysis model of high-speed loading spindle was established by using spring element to simulate bearing boundary condition. The static and dynamic performance of the spindle structure with different specifications of the rectangular spline and the different diameter neck of axle are studied in depth, and the influence of different spindle span on the static and dynamic performance of the high-speed loading spindle is studied. Finally, the optimal structure of the high-speed loading spindle is obtained. The results provide a theoretical basis for improving the overall performance of the test-bed

  2. Progressive high-load strength training compared with general low-load exercises in patients with rotator cuff tendinopathy

    DEFF Research Database (Denmark)

    Ingwersen, Kim G; Christensen, Robin; Sørensen, Lilli

    2015-01-01

    of this trial is to compare the efficacy of progressive high-load exercises with traditional low-load exercises in patients with rotator cuff tendinopathy. Methods/Design: The current study is a randomised, participant- and assessor-blinded, controlled multicentre trial. A total of 260 patients with rotator...... cuff tendinopathy will be recruited from three outpatient shoulder departments in Denmark, and randomised to either 12 weeks of progressive high-load strength training or to general low-load exercises. Patients will receive six individually guided exercise sessions with a physiotherapist and perform...

  3. Stimulus recognition occurs under high perceptual load: Evidence from correlated flankers.

    Science.gov (United States)

    Cosman, Joshua D; Mordkoff, J Toby; Vecera, Shaun P

    2016-12-01

    A dominant account of selective attention, perceptual load theory, proposes that when attentional resources are exhausted, task-irrelevant information receives little attention and goes unrecognized. However, the flanker effect-typically used to assay stimulus identification-requires an arbitrary mapping between a stimulus and a response. We looked for failures of flanker identification by using a more-sensitive measure that does not require arbitrary stimulus-response mappings: the correlated flankers effect. We found that flanking items that were task-irrelevant but that correlated with target identity produced a correlated flanker effect. Participants were faster on trials in which the irrelevant flanker had previously correlated with the target than when it did not. Of importance, this correlated flanker effect appeared regardless of perceptual load, occurring even in high-load displays that should have abolished flanker identification. Findings from a standard flanker task replicated the basic perceptual load effect, with flankers not affecting response times under high perceptual load. Our results indicate that task-irrelevant information can be processed to a high level (identification), even under high perceptual load. This challenges a strong account of high perceptual load effects that hypothesizes complete failures of stimulus identification under high perceptual load. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  4. Increased strength of concrete subject to high loading rates

    International Nuclear Information System (INIS)

    Curbach, M.

    1987-01-01

    Within the scope of this work various problems are discussed which occur in connection with concrete under high tensile loading rates (e.g. when a plane crashes on a nuclear power plant very high loads occur which act only for a very short time). Particularly the causes for the already frequently noticed increases in strength with increasing loading rates are investigated and also the question whether this increased strength can be taken into account when dimensioning a construction. (MM) [de

  5. A novel modelling framework to prioritize estimation of non-point source pollution parameters for quantifying pollutant origin and discharge in urban catchments.

    Science.gov (United States)

    Fraga, I; Charters, F J; O'Sullivan, A D; Cochrane, T A

    2016-02-01

    Stormwater runoff in urban catchments contains heavy metals (zinc, copper, lead) and suspended solids (TSS) which can substantially degrade urban waterways. To identify these pollutant sources and quantify their loads the MEDUSA (Modelled Estimates of Discharges for Urban Stormwater Assessments) modelling framework was developed. The model quantifies pollutant build-up and wash-off from individual impervious roof, road and car park surfaces for individual rain events, incorporating differences in pollutant dynamics between surface types and rainfall characteristics. This requires delineating all impervious surfaces and their material types, the drainage network, rainfall characteristics and coefficients for the pollutant dynamics equations. An example application of the model to a small urban catchment demonstrates how the model can be used to identify the magnitude of pollutant loads, their spatial origin and the response of the catchment to changes in specific rainfall characteristics. A sensitivity analysis then identifies the key parameters influencing each pollutant load within the stormwater given the catchment characteristics, which allows development of a targeted calibration process that will enhance the certainty of the model outputs, while minimizing the data collection required for effective calibration. A detailed explanation of the modelling framework and pre-calibration sensitivity analysis is presented. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Agricultural nutrient loadings to the freshwater environment: the role of climate change and socioeconomic change

    Science.gov (United States)

    Xie, Hua; Ringler, Claudia

    2017-10-01

    Human activities, in particular agricultural production, interfere with natural cycles of nutrient elements, nitrogen (N) and phosphorus (P), leading to growing concerns about water quality degradation related to excessive nutrient loadings. Increases in agricultural production in response to population growth and wealth generation further increase risks associated with nutrient pollution. This paper presents results from projections of nutrient exports from global agricultural crop and pasture systems to the water environment generated using a process-based modeling approach. Brazil, China, India and the United States account for more than half of estimated global N and P loadings in the base year. Each country boasts large agriculture centers where high calculated loading values are found. Rapid growth in global agricultural nutrient loadings is projected. Growth of agricultural pollution loading is fastest in the group of low-income developing countries and loading growth rates also vary substantially with climate change scenario. Counter measures need to be taken to address the environmental risks associated with the projected rapid increase of agricultural nutrient loadings.

  7. Landsat and water pollution

    Science.gov (United States)

    Castruccio, P.; Fowler, T.; Loats, H., Jr.

    1979-01-01

    Report presents data derived from satellite images predicting pollution loads after rainfall. It explains method for converting Landsat images of Eastern United States into cover maps for Baltimore/five county region.

  8. Application of integrated GIS and multimedia modeling on NPS pollution evaluation.

    Science.gov (United States)

    Lin, C E; Kao, C M; Lai, Y C; Shan, W L; Wu, C Y

    2009-11-01

    In Taiwan, nonpoint source (NPS) pollution is one of the major causes of the impairment of surface waters. I-Liao Creek, located in southern Taiwan, flows approximately 90 km and drains toward the Kaoping River. Field investigation results indicate that NPS pollution from agricultural activities is one of the main water pollution sources in the I-Liao Creek Basin. Assessing the potential of NPS pollution to assist in the planning of best management practice (BMP) is significant for improving pollution prevention and control in the I-Liao Creek Basin. In this study, land use identification in the I-Liao Creek Basin was performed by properly integrating the skills of geographic information system (GIS) and global positioning system (GPS). In this analysis, 35 types of land use patterns in the watershed area of the basin are classified with the aid of Erdas Imagine process system and ArcView GIS system. Results indicate that betel palm farms, orchard farms, and tea gardens dominate the farmland areas in the basin, and are scattered around on both sides of the river corridor. An integrated watershed management model (IWMM) was applied for simulating the water quality and evaluating NPS pollutant loads to the I-Liao Creek. The model was calibrated and verified with collected water quality and soil data, and was used to investigate potential NPS pollution management plans. Simulated results indicate that NPS pollution has significant contributions to the nutrient loads to the I-Liao Creek during the wet season. Results also reveal that NPS pollution plays an important role in the deterioration of downstream water quality and caused significant increase in nutrient loads into the basin's water bodies. Simulated results show that source control, land use management, and grassy buffer strip are applicable and feasible BMPs for NPS nutrient loads reduction. GIS system is an important method for land use identification and waste load estimation in the basin. Linking the

  9. Growth of pine ecosystems as a function of climate and pollution load. A regional case study; Wachstum von Kiefern-Oekosystemen in Abhaengigkeit von Klima und Stoffeintrag. Eine regionale Fallstudie auf Landschaftsebene

    Energy Technology Data Exchange (ETDEWEB)

    Erhard, M.

    1999-12-01

    An analysis on landscape level was performed to investigate the growth of Scots pine stands (Pinus sylvestris L.) in the research area of 'Duebener Heide' under the impact of rapidly changing pollution loads and to evaluate their further development. Central to the work was a spatial database, installed using a geographic information system (GIS). This database enabled the statistical analysis of relationships and correlations between the growth of the pine stands, the influence of pollution impacts and the natural site characteristics. The results of emission and immission modelling gave detailed evaluation of the pollution load over the investigated area. The spatial information database was linked with a process-based growth model called FORSANA. The resulting regional model was used to simulate forest growth on stand level for variable time periods. The plausibility of the simulation results of the model was checked for the influence of different patterns of pollution using the data available for the investigated area. Simulation runs were also made with these data to estimate the further development of the pine stand under various climate and emission scenarios. (orig.)

  10. Gearbox Reliability Collaborative Investigation of Gearbox Motion and High-Speed-Shaft Loads

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jon [National Renewable Energy Lab. (NREL), Golden, CO (United States); Guo, Yi [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sethuraman, Latha [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-03-18

    This paper extends a model-to-test validation effort to examine the effect of different constant rotor torque and moment conditions and intentional generator misalignment on the gearbox motion and high-speed-shaft loads. Fully validating gearbox motion and high-speed-shaft loads across a range of test conditions is a critical precursor to examining the bearing loads, as the gearbox motion and high-speed-shaft loads are the drivers of these bearing loads.

  11. Laboratory measurement of secondary pollutant yields from ozone reaction with HVAC filters

    International Nuclear Information System (INIS)

    Destaillats, Hugo; Chen, Wenhao; Apte, Michael; Li, Nuan; Spears, Michael; Almosni, Jeremie; Zhang, Jianshun Jensen; Fisk, William J.

    2009-01-01

    We used Proton Transfer Reaction - Mass Spectrometry (PTR-MS) and conventional sampling methods to monitor and identify trace level organic pollutants formed in heterogeneous reactions between ozone and HVAC filters in real time. Experiments were carried out using a bench-scale flow tube reactor operating with dry air and humidified air (50% RH), at realistically high ozone concentrations (150 ppbv). We explored different filter media (i.e., fiberglass and cotton/polyester blends) and different particle loadings (i.e., clean filter and filters loaded with particles for 3 months at the Lawrence Berkeley National Laboratory and the Port of Oakland, CA). Detailed emission dynamics of very low levels of certain organic pollutants from filter media upon ozone exposure in the presence of moisture have been obtained and analyzed.

  12. GIS-based pollution hazard mapping and assessment framework of shallow lakes: southeastern Pampean lakes (Argentina) as a case study.

    Science.gov (United States)

    Romanelli, A; Esquius, K S; Massone, H E; Escalante, A H

    2013-08-01

    The assessment of water vulnerability and pollution hazard traditionally places particular emphasis on the study on groundwaters more than on surface waters. Consequently, a GIS-based Lake Pollution Hazard Index (LPHI) was proposed for assessing and mapping the potential pollution hazard for shallow lakes due to the interaction between the Potential Pollutant Load and the Lake Vulnerability. It includes easily measurable and commonly used parameters: land cover, terrain slope and direction, and soil media. Three shallow lake ecosystems of the southeastern Pampa Plain (Argentina) were chosen to test the usefulness and applicability of this suggested index. Moreover, anthropogenic and natural medium influence on biophysical parameters in these three ecosystems was examined. The evaluation of the LPHI map shows for La Brava and Los Padres lakes the highest pollution hazard (≈30 % with high to very high category) while Nahuel Rucá Lake seems to be the less hazardous water body (just 9.33 % with high LPHI). The increase in LPHI value is attributed to a different loading of pollutants governed by land cover category and/or the exposure to high slopes and influence of slope direction. Dissolved oxygen and biochemical oxygen demand values indicate a moderately polluted and eutrophized condition of shallow lake waters, mainly related to moderate agricultural activities and/or cattle production. Obtained information by means of LPHI calculation result useful to perform a local diagnosis of the potential pollution hazard to a freshwater ecosystem in order to implement basic guidelines to improve lake sustainability.

  13. Benzo[a]pyrene in urban environments of eastern Moscow: pollution levels and critical loads

    Science.gov (United States)

    Kasimov, Nikolay S.; Kosheleva, Natalia E.; Nikiforova, Elena M.; Vlasov, Dmitry V.

    2017-02-01

    Polycyclic aromatic hydrocarbons (PAHs), particularly benzo[a]pyrene (BaP), are toxic compounds emitted from various anthropogenic sources. Understanding the BaP concentrations, dynamics and decomposition in soil is required to assess the critical loads of BaP in urban environments. This study is the first attempt to evaluate all major input and output components of benzo[a]pyrene (BaP) balance and to calculate the permissible load on the urban environment in different land-use zones in the Eastern district of Moscow. BaP contamination of the snow cover in the Eastern district of Moscow was related to daily BaP fallout from the atmosphere. In 2010, the mean content of the pollutant in the snow dust was 1942 ng g-1, whereas the average intensity of its fallout was 7.13 ng m-2 per day. Across the territory, BaP winter fallout intensities varied from 0.3 to 1100 ng m-2 per day. The average BaP content in the surface (0-10 cm) soil horizons was 409 ng g-1, which is 83 times higher than the local background value and 20 times higher than the maximum permissible concentration (MPC) accepted in Russia. The variations in soil and snow BaP concentrations among different land-use zones were examined. A significant contribution of BaP from the atmosphere to urban soils was identified. Based on the measurements of BaP atmospheric fallout and BaP reserves in the soils, the critical loads of BaP for the land-use zones in the Eastern district were calculated for different values of degradation intensity and different exposure times. It was established that at an annual degradation intensity of 1-10 %, ecologically safe BaP levels in the soils of all land-use zones, excluding the agricultural zone, will only be reached after many decades or centuries.

  14. Spatial and Seasonal Variations of Heavy Metal Loads in Uyo Urban Drainage Stream under PS and NPS Pollution

    Directory of Open Access Journals (Sweden)

    O. E. Essien

    2012-12-01

    Full Text Available The concentration of heavy metals (HM in the 4km urban drainage stream in Uyo was studied using grab and composite sampling of water from six stations on the stream, and analyzed by a multipurpose atomic absorption spectrophotometer. The data were statistically analyzed using SPSS version 17 software arid correlated between stations and among samples. HM contamination was evaluated with the coefficient and rate of dispersion between stations and the Normalized Scatter Coefficient (NSC. The seasonal distribution of metal pollution varied individually amongst metals at stations. The Fe and Pb concentrations exceeded the safe drinking water standard, rendering the water quality not acceptable for drinking; however, the quality was within the safe limit for crop production along the river bank. The relative.dominance of heavy metals followed a different sequence in upstream leachate effluent from all downstream stations. The NSC in dry-wet season was higher than in wet season, and was in the order: Fe>Cu>Zn>Pb, showing that large but variable concentration of Fe from PS and NPS contaminated the stream at faster rate in the wet season while Pb contaminated at nearly constant rate. However, in the dry season, Fe and Pb depleted at downstream at rates far higher than Zn as Cu was increasing. Fe and Pb could be good pollution monitor for total maximum daily load (TMDL pollution monitoring programme.

  15. Enzymatic hydrolysis of biomass at high-solids loadings – A review

    International Nuclear Information System (INIS)

    Modenbach, Alicia A.; Nokes, Sue E.

    2013-01-01

    Enzymatic hydrolysis is the unit operation in the lignocellulose conversion process that utilizes enzymes to depolymerize lignocellulosic biomass. The saccharide components released are the feedstock for fermentation. When performed at high-solids loadings (≥15% solids, w/w), enzymatic hydrolysis potentially offers many advantages over conversions performed at low- or moderate-solids loadings, including increased sugar and ethanol concentrations and decreased capital and operating costs. The goal of this review is to provide a consolidated source of information on studies using high-solids loadings in enzymatic hydrolysis. Included in this review is a brief discussion of the limitations, such as a lack of available water, difficulty with mixing and handling, insufficient mass and heat transfer, and increased concentration of inhibitors, associated with the use of high solids, as well as descriptions and findings of studies that performed enzymatic hydrolysis at high-solids loadings. Reactors designed and/or equipped for improved handling of high-solids slurries are also discussed. Lastly, this review includes a brief discussion of some of the operations that have successfully scaled-up and implemented high-solids enzymatic hydrolysis at pilot- and demonstration-scale facilities. -- Highlights: •High solids enzymatic hydrolysis needed for conversion process to be cost-effective. •Limitations must be addressed before benefits of high-solid loadings fully realized. •Some success with high-solids loadings at pilot and demonstration scale

  16. Characterization and correlations of various pollution parameters in the tannery effluent

    International Nuclear Information System (INIS)

    Haydar, S.

    2008-01-01

    Wastewater characterization is an integral part of treatment and management strategies for industrial effluents. This paper outlines the results of detailed wastewater characterization studies conducted for a tannery in Sheikhupura, Punjab. The results of this study demonstrated that the composition of tannery wastewater could change continuously due to inherent nature of tannery operations. In general, tannery effluent was alkaline in nature and highly polluted in terms of organic, solids, sulfates, sulfides and chromium content. Basic ingredients of tannery effluent i.e. high alkalinity and substantial portions of BOD (Biochemical Oxygen Demand), COD (Chemical Oxygen Demand) and other pollutants in particulate form rendered it suitable for enhanced pollutant removals at primary stage of treatment using suitable coagulants. Results of primary treatment of wastewater from this tannery suggested that primary treatment alone was not capable of reducing pollutant loads significantly. Hence post-primary biological treatment was required to meet local effluent quality standards. (author)

  17. Air Pollution Prevention and Control Policy in China.

    Science.gov (United States)

    Huang, Cunrui; Wang, Qiong; Wang, Suhan; Ren, Meng; Ma, Rui; He, Yiling

    2017-01-01

    With rapid urbanization and development of transport infrastructure, air pollution caused by multiple-pollutant emissions and vehicle exhaust has been aggravated year by year in China. In order to improve air quality, the Chinese authorities have taken a series of actions to control air pollution emission load within a permissible range. However, although China has made positive progress on tackling air pollution, these actions have not kept up with its economy growth and fossil-fuel use. The traditional single-pollutant approach is far from enough in China now, and in the near future, air pollution control strategies should move in the direction of the multiple-pollutant approach. In addition, undesirable air quality is usually linked with the combination of high emissions and adverse weather conditions. However, few studies have been done on the influence of climate change on atmospheric chemistry in the global perspective. Available evidence suggested that climate change is likely to exacerbate certain kinds of air pollutants including ozone and smoke from wildfires. This has become a major public health problem because the interactions of global climate change, urban heat islands, and air pollution have adverse effects on human health. In this chapter, we first review the past and current circumstances of China's responses to air pollution. Then we discuss the control challenges and future options for a better air quality in China. Finally, we begin to unravel links between air pollution and climate change, providing new opportunities for integrated research and actions in China.

  18. Astyanax fasciatus as bioindicator of water pollution of Rio dos Sinos, RS, Brazil

    Directory of Open Access Journals (Sweden)

    U. H. SCHULZ

    Full Text Available The effects of an increasing downriver pollution gradient on the reproductive system of Astyanax fasciatus were investigated in the Rio dos Sinos, RS. The comparison of mean oocyte diameters, gonadal indices and gonado-somatic relationships of specimens captured in polluted areas with individuals from unpolluted reference sites revealed a significant decrease of these parameters with increasing water pollution. High loads of organic and industrial sewage are considered responsible for these effects. Condition factors showed an inverse relationship, and increased significantly in downriver polluted areas. The declining gonadal indices showed that energy was allocated to somatic growth. The results of the study recommend the use of A. fasciatus in biomonitoring essays.

  19. Astyanax fasciatus as bioindicator of water pollution of Rio dos Sinos, RS, Brazil

    Directory of Open Access Journals (Sweden)

    SCHULZ U. H.

    2001-01-01

    Full Text Available The effects of an increasing downriver pollution gradient on the reproductive system of Astyanax fasciatus were investigated in the Rio dos Sinos, RS. The comparison of mean oocyte diameters, gonadal indices and gonado-somatic relationships of specimens captured in polluted areas with individuals from unpolluted reference sites revealed a significant decrease of these parameters with increasing water pollution. High loads of organic and industrial sewage are considered responsible for these effects. Condition factors showed an inverse relationship, and increased significantly in downriver polluted areas. The declining gonadal indices showed that energy was allocated to somatic growth. The results of the study recommend the use of A. fasciatus in biomonitoring essays.

  20. High efficient multifunctional Ag_3PO_4 loaded hydroxyapatite nanowires for water treatment

    International Nuclear Information System (INIS)

    Li, Yaling; Zhou, Hangyu; Zhu, Genxing; Shao, Changyu; Pan, Haihua; Xu, Xurong; Tang, Ruikang

    2015-01-01

    Highlights: • The multifunctional Ag_3PO_4 loaded hydroxyapatite (HAP) nanowires were synthesized via a facile in-situ precipitation method. • By optimizing the initial concentration of AgNO_3, the well-distributed Ag_3PO_4/HAP composites could be achieved. • The Ag_3PO_4/HAP composites showed excellent photocatalytic performance for the decomposition of dyes under visible light irradiation. • The maximum absorption capacity of the Ag_3PO_4/HAP composites for Pb(II) was 250 mg/g, approximately three times as that of pure HAP. • The Ag_3PO_4/HAP composites also exhibited excellent antibacterial activities even at relative low concentrations. - Abstract: Organic, inorganic, and biological pollutants are typical water contaminants and they seriously affect water quality. In this study, we suggested that a novel multifunctional Ag_3PO_4 loaded hydroxyapatite (HAP) material can remove the typical pollutants from water. The Ag_3PO_4/HAP composites were synthesized facilely via in-situ precipitation of Ag_3PO_4 on the pre-existing HAP nanowires. By optimizing the composition of Ag_3PO_4 and HAP, the material could achieve an optimal photocatalytic activity to decompose rhodamine B (RhB), methyl orange (MO) and methylene blue (MB) under visible light irradiations with enhanced pH stability. Besides, the adsorption of Pb(II) on the Ag_3PO_4/HAP reached a maximum capacity of 250 mg/g and this value was approximately three times as that of pure HAP. Furthermore, the composite material exhibited excellent antibacterial activities towards gram-negative bacterium (Escherichia coli) and gram-positive bacterium (Stphylococcus aureus). The results highlighted the cooperative effect between Ag_3PO_4 and hydroxyapatite (HAP). The simultaneous removals of dyes, toxic metal ions, and bacteria with a high efficiency followed an easy approach for the purification of contaminated water via the rationally designed material, in which the Ag_3PO_4/HAP composite might be developed

  1. Macrophyte Community Response to Nitrogen Loading and ...

    Science.gov (United States)

    Empirical determination of nutrient loading thresholds that negatively impact seagrass communities have been elusive due to the multitude of factors involved. Using a mesocosm system that simulated Pacific Northwest estuaries, we evaluated macrophyte metrics across gradients of NO3 loading (0, 1.5, 3 and 6x ambient) and temperature (10 and 20 °C). Macroalgal growth, biomass, and C:N responded positively to increased NO3 load and floating algal mats developed at 20 ºC. Zostera japonica metrics, including C:N, responded more to temperature than to NO3 loading. Z. marina biomass exhibited a negative temperature effect and in some cases a negative NO3 effect, while growth rate increased with temperature. Shoot survival decreased at 20 ºC but was not influenced by NO3 loading. Wasting disease index exhibited a significant temperature by NO3 interaction consistent with increased disease susceptibility. Community shifts observed were consistent with the nutrient loading hypothesis at 20 ºC, but there was no evidence of other eutrophication symptoms due to the short residence time. The Nutrient Pollution Index tracked the NO3 gradient at 10 ºC but exhibited no response at 20 ºC. We suggest that systems characterized by cool temperatures, high NO3 loads, and short residence time may be resilient to many symptoms of eutrophication. Estuarine systems characterized by cool temperatures, high nutrient loads and rapid flushing may be resilient to some symptoms

  2. Performance of double-layer biofilter packed with coal fly ash ceramic granules in treating highly polluted river water.

    Science.gov (United States)

    Jing, Zhaoqian; Li, Yu-You; Cao, Shiwei; Liu, Yuyu

    2012-09-01

    To improve trickling filters' denitrification efficiency, a biofilter with a trickling upper layer and a submerged lower layer was developed and applied in treating highly polluted river water. It was packed with porous coal fly ash ceramic granules. Its start-up characteristics, influence of hydraulic loading rates (HLR), carbon/nitrogen (C/N) ratio and filter depth on pollutants removal were investigated. The results indicated this biofilter was started quickly in 16 days with river sediment as inoculum. Alternating nitrification and denitrification were achieved when water flowed downwards. COD and nitrogen were mainly removed in the upper layer and the lower layer, respectively. With HLR of 4.0-5.0m(3)/(m(2)d), chemical oxygen demand (COD), ammonium (NH(4)(+)-N) and total nitrogen (TN) in the effluent were below 50, 5 and 15 mg/L, respectively. This biofilter removed more than 80% of COD, 85% of NH(4)(+)-N and 60% of TN with C/N ratios ranging from 6 to 10. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Characterisation of diffuse pollutions from forested watersheds in Japan during storm events - its association with rainfall and watershed features.

    Science.gov (United States)

    Zhang, Zhao; Fukushima, Takehiko; Onda, Yuichi; Mizugaki, Shigeru; Gomi, Takashi; Kosugi, Ken'ichirou; Hiramatsu, Shinya; Kitahara, Hikaru; Kuraji, Koichiro; Terajima, Tomomi; Matsushige, Kazuo; Tao, Fulu

    2008-02-01

    Forest areas have been identified as important sources of nonpoint pollution in Japan. The managers must estimate stormwater quality and quantities from forested watersheds to develop effective management strategies. Therefore, stormwater runoff loads and concentrations of 10 constituents (total suspended solids, dissolved organic carbon, PO(4)-P, dissolved total phosphorus, total phosphorus, NH(4)-N, NO(2)-N, NO(3)-N, dissolved total nitrogen, and total nitrogen) for 72 events across five regions (Aichi, Kochi, Mie, Nagano, and Tokyo) were characterised. Most loads were significantly and positively correlated with stormwater variables (total event rainfall, event duration, and rainfall intensity), but most discharge-weighted event concentrations (DWECs) showed negative correlations with rainfall intensity. Mean water quality concentration during baseflow was correlated significantly with storm concentrations (r=0.41-0.77). Although all pollutant load equations showed high coefficients of determination (R(2)=0.55-0.80), no models predicted well pollutant concentrations, except those for the three N constituents (R(2)=0.59-0.67). Linear regressions to estimate stormwater concentrations and loads were greatly improved by regional grouping. The lower prediction capability of the concentration models for Mie, compared with the other four regions, indicated that other watershed or storm characteristics should be included in the prediction models. Significant differences among regions were found more frequently in concentrations than in loads for all constituents. Since baseflow conditions implied available pollutant sources for stormwater, the similar spatial characteristics of pollutant concentrations between baseflow and stormflow conditions were an important control for stormwater quality.

  4. Cementitious Stabilization of Mixed Wastes with High Salt Loadings

    International Nuclear Information System (INIS)

    Spence, R.D.; Burgess, M.W.; Fedorov, V.V.; Downing, D.J.

    1999-01-01

    Salt loadings approaching 50 wt % were tolerated in cementitious waste forms that still met leach and strength criteria, addressing a Technology Deficiency of low salt loadings previously identified by the Mixed Waste Focus Area. A statistical design quantified the effect of different stabilizing ingredients and salt loading on performance at lower loadings, allowing selection of the more effective ingredients for studying the higher salt loadings. In general, the final waste form needed to consist of 25 wt % of the dry stabilizing ingredients to meet the criteria used and 25 wt % water to form a workable paste, leaving 50 wt % for waste solids. The salt loading depends on the salt content of the waste solids but could be as high as 50 wt % if all the waste solids are salt

  5. Lightweight, high-opacity Bible paper by fiber loading

    Science.gov (United States)

    Klaus Doelle; Oliver Heise; John H. Klungness; Said M. AbuBakr

    2000-01-01

    This paper has been prepared in order to discuss Fiber Loading™ for lightweight, high-opacity bible paper. Incorporating fillers within pulp fibers has been subject to research since 1960 (Green et al. 1962, Scallan et al. 1985, Allen et al. 1992). Fiber Loading™ is a method for manufacturing precipitated calcium carbonate (PCC) directly within the pulp processing...

  6. Mesophilic and thermophilic biotreatment of BTEX-polluted air in reactors.

    Science.gov (United States)

    Mohammad, Balsam T; Veiga, María C; Kennes, Christian

    2007-08-15

    This study compares the removal of a mixture of benzene, toluene, ethylbenzene, and all three xylene isomers (BTEX) in mesophilic and thermophilic (50 degrees C) bioreactors. In the mesophilic reactor fungi became dominant after long-term operation, while bacteria dominated in the thermophilic unit. Microbial acclimation was achieved by exposing the biofilters to initial BTEX loads of 2-15 g m(-3) h(-1), at an empty bed residence time of 96 s. After adaptation, the elimination capacities ranged from 3 to 188 g m(-3) h(-1), depending on the inlet load, for the mesophilic biofilter with removal efficiencies reaching 96%. On the other hand, in the thermophilic reactor the average removal efficiency was 83% with a maximum elimination capacity of 218 g m(-3) h(-1). There was a clear positive relationship between temperature gradients as well as CO(2) production and elimination capacities across the biofilters. The gas phase was sampled at different depths along the reactors observing that the percentage pollutant removal in each section was strongly dependant on the load applied. The fate of individual alkylbenzene compounds was checked, showing the unusually high biodegradation rate of benzene at high loads under thermophilic conditions (100%) compared to its very low removal in the mesophilic reactor at such load (<10%). Such difference was less pronounced for the other pollutants. After 210 days of operation, the dry biomass content for the mesophilic and thermophilic reactors were 0.300 and 0.114 g g(-1) (support), respectively, reaching higher removals under thermophilic conditions with a lower biomass accumulation, that is, lower pressure drop. (c) 2007 Wiley Periodicals, Inc.

  7. Vehicular pollution modeling using the operational street pollution model (OSPM) for Chembur, Mumbai (India).

    Science.gov (United States)

    Kumar, Awkash; Ketzel, Matthias; Patil, Rashmi S; Dikshit, Anil Kumar; Hertel, Ole

    2016-06-01

    Megacities in India such as Mumbai and Delhi are among the most polluted places in the world. In the present study, the widely used operational street pollution model (OSPM) is applied for assessing pollutant loads in the street canyons of Chembur, a suburban area just outside Mumbai city. Chembur is both industrialized and highly congested with vehicles. There are six major street canyons in this area, for which modeling has been carried out for NOx and particulate matter (PM). The vehicle emission factors for Indian cities have been developed by Automotive Research Association of India (ARAI) for PM, not specifically for PM10 or PM2.5. The model has been applied for 4 days of winter season and for the whole year to see the difference of effect of meteorology. The urban background concentrations have been obtained from an air quality monitoring station. Results have been compared with measured concentrations from the routine monitoring performed in Mumbai. NOx emissions originate mainly from vehicles which are ground-level sources and are emitting close to where people live. Therefore, those emissions are highly relevant. The modeled NOx concentration compared satisfactorily with observed data. However, this was not the case for PM, most likely because the emission inventory did not contain emission terms due to resuspended particulate matter.

  8. Amoco-US Environmental Protection Agency, pollution prevention project, Yorktown, Virginia: Surface water data

    International Nuclear Information System (INIS)

    Baloo, S.

    1991-08-01

    The report summarizes the surface water sampling program at the Amoco Refinery at Yorktown, Virginia. This was undertaken as a part of the joint project between Amoco Corporation and the United States Environmental Protection Agency to review pollution prevention alternatives at a petroleum refinery. The surface water data provides a snapshot of surface water pollutant generation and discharge from the refinery. Different process units contribute to the total wastewater flow of 460 GPM in the refinery. Water in the ditch system, which is non-process water, is free of organic contamination. Oil and grease, phenols, ammonia and sulfides are the significant components measured in the process wastewater. The concentrations of organics in most water streams leaving the individual process units are relatively low, in the 1-5 parts per million (ppm) range. A few individual streams such as the crude desalter brine and tank water draws have high pollutant loadings. Concentrations of metals in the refinery wastewater are very low. The wastewater treatment plant is very effective in reducing the pollutant loading in the water with overall removal efficiencies greater than 99% for most organics and inorganics

  9. Transparent bulk-size nanocomposites with high inorganic loading

    International Nuclear Information System (INIS)

    Chen, Shi; Gaume, Romain

    2015-01-01

    With relatively high nanoparticle loading in polymer matrices, hybrid nanocomposites made by colloidal dispersion routes suffer from severe inhomogeneous agglomeration, a phenomenon that deteriorates light transmission even when the refractive indices of the inorganic and organic phases are closely matched. The dispersion of particles in a matrix is of paramount importance to obtain composites of high optical quality. Here, we describe an innovative, yet straightforward method to fabricate monolithic transparent hybrid nanocomposites with very high particle loading and high refractive index mismatch tolerance between the inorganic and organic constituents. We demonstrate 77% transmission at 800 nm in a 2 mm-thick acrylate polymer nanocomposite containing 61 vol. % CaF 2 nanoparticles. Modeling shows that similar performance could easily be obtained with various inorganic phases relevant to a number of photonic applications

  10. A quarter century of biomonitoring atmospheric pollution in the Czech Republic.

    Science.gov (United States)

    Suchara, Ivan; Sucharová, Julie; Holá, Marie

    2017-05-01

    The Czech Republic (CZ) had extremely high emissions and atmospheric deposition of pollutants in the second half of the 1980s. Since the beginning of the 1990s, moss, spruce bark and forest floor humus have been used as bioindicators of air quality. In the first half of the 1990s, seven larger areas were found to be affected by high atmospheric deposition loads. Six of these "hot spots" were caused by industrial pollution sources, mainly situated in coal basins in the NW and NE part of the country, and one large area in the SE was affected by increased deposition loads of eroded soil particles. After restructuring of industry in CZ, these hot spots were substantially reduced or even disappeared between 1995 and 2000. Since 2000, only two larger areas with slightly increased levels of industrial pollutant deposition and a larger area affected by soil dust have repeatedly been identified by biomonitoring. The distribution of lead isotope ratios in moss showed the main deposition zones around important emission sources. Very high SO 2 emissions led to extreme acidity of spruce bark extracts (pH of about 2.3) at the end of the 1980s. The rate of increasing bark pH was strikingly similar to the rate of recovery of acid wet deposition measured at forest stations in CZ. By about 2005, when the median pH value in bark increased to about 3.2, the re-colonisation of trees by several epiphyte lichen species was observed throughout CZ. An increase in the accumulation of Chernobyl-derived 137 Cs in bark was detected at about ten sites affected by precipitation during the time when radioactive plumes crossed CZ (1986). Accumulated deposition loads in forest floor humus corresponded to the position of the moss and bark hot spots.

  11. Vitrification of highly-loaded SDS zeolites

    International Nuclear Information System (INIS)

    Siemens, D.H.; Bryan, G.H.; Knowlton, D.E.; Knox, C.A.

    1982-11-01

    Pacific Northwest Laboratory (PNL) is demonstrating a vitrification system designed for immobilization of highly loaded SDS zeolites. The Zeolite Vitrification Demonstration Project (ZVDP) utilizes an in-can melting process. All steps of the process have been demonstrated, from receipt of the liners through characterization of the vitrified product. The system has been tested with both nonradioactive and radioactive zeolite material. Additional high-radioactivity demonstrations are scheduled to begin in FY-83. 5 figures, 4 tables

  12. A systematic assessment of watershed-scale nonpoint source pollution during rainfall-runoff events in the Miyun Reservoir watershed.

    Science.gov (United States)

    Qiu, Jiali; Shen, Zhenyao; Wei, Guoyuan; Wang, Guobo; Xie, Hui; Lv, Guanping

    2018-03-01

    The assessment of peak flow rate, total runoff volume, and pollutant loads during rainfall process are very important for the watershed management and the ecological restoration of aquatic environment. Real-time measurements of rainfall-runoff and pollutant loads are always the most reliable approach but are difficult to carry out at all desired location in the watersheds considering the large consumption of material and financial resources. An integrated environmental modeling approach for the estimation of flash streamflow that combines the various hydrological and quality processes during rainstorms within the agricultural watersheds is essential to develop targeted management strategies for the endangered drinking water. This study applied the Hydrological Simulation Program-Fortran (HSPF) to simulate the spatial and temporal variation in hydrological processes and pollutant transport processes during rainstorm events in the Miyun Reservoir watershed, a drinking water resource area in Beijing. The model performance indicators ensured the acceptable applicability of the HSPF model to simulate flow and pollutant loads in the studied watershed and to establish a relationship between land use and the parameter values. The proportion of soil and land use was then identified as the influencing factors of the pollution intensities. The results indicated that the flush concentrations were much higher than those observed during normal flow periods and considerably exceeded the limits of Class III Environmental Quality Standards for Surface Water (GB3838-2002) for the secondary protection zones of the drinking water resource in China. Agricultural land and leached cinnamon soils were identified as the key sources of sediment, nutrients, and fecal coliforms. Precipitation volume was identified as a driving factor that determined the amount of runoff and pollutant loads during rainfall processes. These results are useful to improve the streamflow predictions, provide

  13. Graphene-coated materials using silica particles as a framework for highly efficient removal of aromatic pollutants in water

    Science.gov (United States)

    Yang, Kaijie; Chen, Baoliang; Zhu, Lizhong

    2015-01-01

    The substantial aggregation of pristine graphene nanosheets decreases its powerful adsorption capacity and diminishes its practical applications. To overcome this shortcoming, graphene-coated materials (GCMs) were prepared by loading graphene onto silica nanoparticles (SiO2). With the support of SiO2, the stacked interlamination of graphene was held open to expose the powerful adsorption sites in the interlayers. The adsorption of phenanthrene, a model aromatic pollutant, onto the loaded graphene nanosheets increased up to 100 fold compared with pristine graphene at the same level. The adsorption of GCMs increased with the loading amount of the graphene nanosheets and dramatically decreased with the introduction of oxygen-containing groups in the graphene nanosheets. The highly hydrophobic effect and the strong π-π stacking interactions of the exposed graphene nanosheets contributed to their superior adsorption of GCMs. An unusual GCM peak adsorption coefficient (Kd) was observed with the increase in sorbate concentration. The sorbate concentration at peak Kd shifted to lower values for the reduced graphene oxide and graphene relative to the graphene oxide. Therefore, the replacement of water nanodroplets attached to the graphene nanosheets through weak non-hydrogen bonding with phenanthrene molecules via strong π-π stacking interactions is hypothesized to be an additional adsorption mechanism for GCMs. PMID:26119007

  14. Multi-pollutant interactions in hyporheic zones

    Science.gov (United States)

    Krause, S.; Weatherill, J.; Bonet, B.; Blaen, P.; Khamis, K.; Cassidy, N. J.; Hannah, D. M.; Rivett, M. O.; Lynch, I.; Ullah, S.

    2017-12-01

    Hyporheic zones represent hotspots of biogeochemical reactivity, with the potential to attenuate pollutants and ameliorate their impact on ecosystem functioning. Sources and types of pollutants in streambed environments are manifold, with legacy industry contaminants, agricultural pollution and emerging pollutants such as pharmaceuticals or engineered nanoparticles entering hyporheic zones along different flow paths where they mix and potentially react with each other. Current conceptualizations of drivers and controls of biogeochemical turnover in hyporheic zones highlight primarily the role of transport and reaction times but do not account for potential interactions between different pollutants. This study presents two case studies of multi-pollutant interactions to illustrate the need to consider interferences between different pollutants, their transport and reaction pathways for adequate impact assessment. We discuss in the first instance how the natural attenuation of a Trichloroethylene (TCE) groundwater plume in an agricultural catchment is limited by high riparian and hyporheic nitrate concentrations. As nitrate outcompeted TCE in its reaction with organic carbon as electron donor, TCE attenuation was in this case limited to hyporheic denitrification hotspots. Hence any pollution control measures to reduce the impact of this TCE plume require a reduction of agricultural nitrate loads, highlighting the connectedness of legacy (TCE) and more recent (nitrate) pollution problems. In the second case, we investigate how the labile organic carbon content of streambed sediments as main control of hyporheic respiration is overridden by exposure to different silver nanoparticle concentrations, representing emerging pollutants in many of our rivers. Also in this case, the impacts of different stressors (nanoparticle exposure) and drivers (availability of organic matter, water temperature) are interacting in their impacts on hyporheic zone functioning. We argue that

  15. Assessment of Non-Point Source Total Phosphorus Pollution from Different Land Use and Soil Types in a Mid-High Latitude Region of China

    Directory of Open Access Journals (Sweden)

    Zhiwei Wang

    2016-11-01

    Full Text Available The transport characteristics of phosphorus in soil and the assessment of its environmental risk have become hot topics in the environmental and agricultural fields. The Sanjiang Plain is an important grain production base in China, and it is characterised by serious land use change caused by large-scale agricultural exploitation. Agricultural inputs and tillage management have destroyed the soil nutrient balance formed over long-term conditions. There are few studies on non-point source phosphorus pollution in the Sanjiang Plain, which is the largest swampy low plain in a mid-high-latitude region in China. Most studies have focused on the water quality of rivers in marsh areas, or the export mechanism of phosphorus from specific land uses. They were conducted using experimental methods or empirical models, and need further development towards mechanism models and the macro-scale. The question is how to find a way to couple processes in phosphorus cycling and a distributed hydrological model considering local hydrological features. In this study, we report an attempt to use a distributed phosphorus transport model to analyse non-point source total phosphorus pollution from different land uses and soil types on the Sanjiang Plain. The total phosphorus concentration generally shows an annually increasing trend in the study area. The total phosphorus load intensity is heterogeneous in different land use types and different soil types. The average total phosphorus load intensity of different land use types can be ranked in descending order from paddy field, dry land, wetlands, grassland, and forestland. The average total phosphorus load intensity of different soil types can be ranked in descending order: paddy soil, bog soil, planosol, meadow soil, black soil, and dark brown earth. The dry land and paddy fields account for the majority of total phosphorus load in the study area. This is mainly caused by extensive use of phosphate fertilizer on the

  16. Cadmium and high temperature effects on brain and behaviour of Lymantria dispar L. caterpillars originating from polluted and less-polluted forests.

    Science.gov (United States)

    Perić-Mataruga, Vesna; Petković, Branka; Ilijin, Larisa; Mrdaković, Marija; Dronjak Čučaković, Slađana; Todorović, Dajana; Vlahović, Milena

    2017-10-01

    Insects brain as a part of nervous system is the first-line of fast stress response that integrate stress signals to regulate all aspects of insect physiology and behaviour. The cadmium (Cd) bioaccumulation factor (BF), activity of the neurotoxicity biomarker acetylcholinesterase (AChE), dopamine content, expression and amount of Hsp70 in the brain and locomotor activity were evaluated in the 4th instar of Lymantria dispar L. caterpillars fed a Cd supplemented diet and reared in an optimal temperature regime (23 °C) and/or exposed to high temperature (28 °C). The insects originated from two forests, one close to "Nikola Tesla" thermoelectric power plant, Obrenovac (polluted population), and the other Kosmaj mountain (less-polluted population, far from any industrial region). The Cd BF was higher in the less-polluted than in the polluted population especially at the high ambient temperature. AChE activity and dopamine content were changed in the brains of L. dispar from both populations in the same manner. Hsp70 concentration in caterpillar brains showed opposite trends, a decrease in the less-polluted and an increase in the polluted population. Locomotor activity was modified in both Lymantria dispar populations, but the pattern of changes depended on the stressors and their combined effect. ACh activity and dopamine content are sensitive parameters to Cd exposure, regardless of pollutant experience, and might be promising biomarkers in monitoring forest ecosystems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Environmental Kuznets curve analysis of the economic development and nonpoint source pollution in the Ningxia Yellow River irrigation districts in China.

    Science.gov (United States)

    Mao, Chunlan; Zhai, Ningning; Yang, Jingchao; Feng, Yongzhong; Cao, Yanchun; Han, Xinhui; Ren, Guangxin; Yang, Gaihe; Meng, Qing-xiang

    2013-01-01

    This study applies the environmental Kuznets curve to test the relationship between the regional economic growth and the different types of agricultural nonpoint source pollution loads in the Ningxia Yellow River irrigation area by using the Johnes export coefficient method. Results show that the pollution load generated by crop cultivation and livestock-breeding industries in the Ningxia Yellow River irrigation area shows an inverted U-shaped feature; however, this feature is absent in living-sewage pollution load. Crop pollution has shown a decreasing trend since 1997 because of the increased per capita income of farmers. Livestock-breeding pollution load reached its turning point when the per capita income of farmers reached 8386.74 RMB. Therefore, an increase in the per capita income of farmers corresponds to an increase in the livestock-breeding pollution load in the Ningxia Yellow River irrigation area.

  18. Magnetic evidence for heavy metal pollution of topsoil in Shanghai, China

    Science.gov (United States)

    Wang, Guan; Liu, Yuan; Chen, Jiao; Ren, Feifan; Chen, Yuying; Ye, Fangzhou; Zhang, Weiguo

    2018-03-01

    This study presents the results obtained from magnetic susceptibility and heavy metal (Cu, Zn, Pb, and Cr) concentration measurements of soil profiles collected from arable land and urban parks in Baoshan District, an industrial district of Shanghai, China. The study focuses on the investigation of vertical variations in magnetic susceptibilities and heavy metal concentrations and on correlations between magnetic susceptibilities and heavy metal concentrations in soil profiles. The results demonstrate that magnetic enhancement in the surface layer of the soil profile is associated with increased heavy metal pollution. The enrichment factors (EF) and the Tomlinson Pollution Load Index (PLI-EF) are calculated for estimating the level of heavy metal pollution of soil profiles in the study. The significant positive correlations between heavy metal contents, enrichment factors (EF), Tomlinson pollution load index (PLI-CF), modified Tomlinson pollution load index (PLI-EF), and magnetic susceptibility (c) indicate that much of the heavy metal contamination in the study area is linked to combustion derived particulate emissions. The results confirm that the combined magnetic measurement and heavy metal concentration analysis could provide useful information for soil monitoring in urban environments. However, the use of magnetic technique to locate the heavy metal pollution boundary in the soil profile of this studied area should be confirmed by further geochemical analysis.

  19. Implications of salinity pollution hotspots on agricultural production

    Science.gov (United States)

    Floerke, Martina; Fink, Julia; Malsy, Marcus; Voelker, Jeanette; Alcamo, Joseph

    2016-04-01

    Salinity pollution can have many negative impacts on water resources used for drinking, irrigation, and industrial purposes. Elevated concentrations of salinity in irrigation water can lead to decreased crop production or crop death and, thus, causing an economic problem. Overall, salinity pollution is a global problem but tends to be more severe in arid and semi-arid regions where the dilution capacity of rivers and lakes is lower and the use of irrigation higher. Particularly in these regions agricultural production is exposed to high salinity of irrigation water as insufficient water quality further reduces the available freshwater resources. According to the FAO, irrigated agriculture contributes about 40 percent of the total food production globally, and therefore, high salinity pollution poses a major concern for food production and food security. We use the WaterGAP3 modeling framework to simulate hydrological, water use, and water quality conditions on a global scale for the time period 1990 to 2010. The modeling framework is applied to simulate total dissolved solids (TDS) loadings and in-stream concentrations from different point and diffuse sources to get an insight on potential environmental impacts as well as risks to agricultural food production. The model was tested and calibrated against observed data from GEMStat and literature sources. Although global in scope, the focus of this study is on developing countries, i.e., in Africa, Asia, and Latin America, as these are most threatened by salinity pollution. Furthermore, insufficient water quality for irrigation and therefore restrictions in irrigation water use are examined, indicating limitations to crop production. Our results show that elevated salinity concentrations in surface waters mainly occur in peak irrigation regions as irrigated agriculture is not only the most relevant water use sector contributing to water abstractions, but also the dominant source of salinity pollution. Additionally

  20. High heat load synchrotron optics

    International Nuclear Information System (INIS)

    Mills, D.M.

    1993-01-01

    Third generation synchrotron radiation sources currently being constructed worldwide will produce x-ray beams of unparalleled power and power density. These high heat fluxes coupled with the stringent dimensional requirements of the x-ray optical components pose a prodigious challenge to designers of x-ray optical elements, specifically x-ray mirrors and crystal monochromators. Although certain established techniques for the cooling of high heat flux components can be directly applied to this problem, the thermal management of high heat load x-ray optical components has several unusual aspects that may ultimately lead to unique solutions. This manuscript attempts to summarize the various approaches currently being applied to this undertaking and to point out the areas of research that require further development

  1. Stormwater Management: Calculation of Traffic Area Runoff Loads and Traffic Related Emissions

    Directory of Open Access Journals (Sweden)

    Maximilian Huber

    2016-07-01

    Full Text Available Metals such as antimony, cadmium, chromium, copper, lead, nickel, and zinc can be highly relevant pollutants in stormwater runoff from traffic areas because of their occurrence, toxicity, and non-degradability. Long-term measurements of their concentrations, the corresponding water volumes, the catchment areas, and the traffic volumes can be used to calculate specific emission loads and annual runoff loads that are necessary for mass balances. In the literature, the annual runoff loads are often specified by a distinct catchment area (e.g., g/ha. These loads were summarized and discussed in this paper for all seven metals and three types of traffic areas (highways, parking lots, and roads; 45 sites. For example, the calculated median annual runoff loads of all sites are 355 g/ha for copper, 110 g/ha for lead (only data of the 21st century, and 1960 g/ha for zinc. In addition, historical trends, annual variations, and site-specific factors were evaluated for the runoff loads. For Germany, mass balances of traffic related emissions and annual heavy metal runoff loads from highways and total traffic areas were calculated. The influences on the mass fluxes of the heavy metal emissions and the runoff pollution were discussed. However, a statistical analysis of the annual traffic related metal fluxes, in particular for different traffic area categories and land uses, is currently not possible because of a lack of monitoring data.

  2. Performance Limiting Flow Processes in High-State Loading High-Mach Number Compressors

    National Research Council Canada - National Science Library

    Tan, Choon S

    2008-01-01

    In high-stage loading high-Mach number (HLM) compressors, counter-rotating pairs of discrete vortices are shed at the trailing edge of the upstream blade row at a frequency corresponding to the downstream rotor blade passing frequency...

  3. Thermal pollution in rivers: Will adding gravel help to cool them down?

    Science.gov (United States)

    Marie Oliver; Gordon Grant; Barbara Burkholder

    2011-01-01

    Thermal pollution in rivers can be caused by dams, logging, municipal wastewater treatment, and other human activities. High water termperatures stress ecosystems, kill fish, and promote disease and parasites, and so dam operators, timber companies, and municipalities are held responsible for thermal loading caused by their operations. These entities are looking for...

  4. Pre-estimation of loading on water bodies from peat production and new pollution control methods (TuVeKu); Turvetuotannon vesistoekuormituksen ennakointi ja uudet hallintamenetelmaet

    Energy Technology Data Exchange (ETDEWEB)

    Klove, B.; Saukkoriipi, J.; Tuukkanen, T.; Heiderscheidt, E.; Heikkinen, K.; Marttila, H.; Ihme, R.; Depre, L.; Karppinen, A.

    2012-10-15

    Approximately 25 million cubic metres of peat are produced in Finland each year. Furthermore 23 million cubic metres of peat is extracted for energy purposes in Finland, which is more than 50% of the world's energy peat production. Peat extraction activities such as drainage and the exposure of peat layers are known to increase the amount of water discharging from the catchment areas and to increase the loading of suspended solids and nutrients, like phosphorus and nitrogen. Hence every effort has to be made to reduce pollution from peat extraction by means of the best viable technologies that take account of the whole life-cycle impact on water bodies. Overland flow areas are considered as one of the best available technologies (BAT) for purifying run-off water. Wetlands that are constructed to already drained mires are also a common and practical method of protecting waters nowadays, as undrained areas of mires close to peat extraction areas are often lacking. Constructed wetlands however are not considered to BAT so far. The chemical purification of runoff waters is considered to one of the best available technologies. However the limiting factor for chemical treatment has often been the high costs of the method. Thus the less expensive small-scale chemical treatment has become a norm in small peat production areas with stringent purification requirements. However, there is still insufficient amount of knowledge regarding how effective drained wetlands and small-scale chemical treatment are in the purification of runoff waters. The 'Pre-estimation of loading on water bodies from peat production and new pollution control methods' project (TuVeKu) had two main objectives: (I) To assess the effect of the local and structural characteristics of the peat production areas and water treatment structures to the detected variations in the purification efficiencies. The statistical analysis is based on the gathered pollution monitoring data and gathered

  5. Air pollution tolerance indices of some plants around Ama industrial ...

    African Journals Online (AJOL)

    SAM

    2014-03-12

    Mar 12, 2014 ... Table 1. Air pollution tolerance index (APTI) of some plant species around some industries in Ama, Enugu State, Nigeria. Plant specie. Site .... these receive most impact from the pollution load in the environment. APTI is an inherent quality of plants to encounter air pollution stress (Rai et al., 2013). These.

  6. Beam loading in high-energy storage rings

    International Nuclear Information System (INIS)

    Wilson, P.B.

    1974-06-01

    The analysis of beam loading in the RF systems of high-energy storage rings (for example, the PEP e/sup /minus//e/sup +/ ring) is complicated by the fact that the time, T/sub b/, between the passage of successive bunches is comparable to the cavity filling time, T/sub b/. In this paper, beam loading expressions are first summarized for the usual case in which T/sub b/ /much lt/ T/sub f/. The theory of phase oscillations in the heavily-beam-loaded case is considered, and the dependence of the synchrotron frequency and damping constant for the oscillations on beam current and cavity tuning is calculated. Expressions for beam loading are then derived which are valid for any value of the ratio T/sub b//T/sub f/. It is shown that, for the proposed PEP e/sup /minus//e/sup +/ ring parameters, the klystron power required is increased by about 3% over that calculated using the standard beam loading expressions. Finally, the analysis is extended to take into account the additional losses associated with the excitation of higher-order cavity modes. A rough numerical estimate is made of the loss enhancement to be expected for PEP RF system. It is concluded that this loss enhancement might be substantial unless appropriate measures are taken in the design and tuning of the accelerating structure

  7. Environmental Kuznets Curve Analysis of the Economic Development and Nonpoint Source Pollution in the Ningxia Yellow River Irrigation Districts in China

    Directory of Open Access Journals (Sweden)

    Chunlan Mao

    2013-01-01

    Full Text Available This study applies the environmental Kuznets curve to test the relationship between the regional economic growth and the different types of agricultural nonpoint source pollution loads in the Ningxia Yellow River irrigation area by using the Johnes export coefficient method. Results show that the pollution load generated by crop cultivation and livestock-breeding industries in the Ningxia Yellow River irrigation area shows an inverted U-shaped feature; however, this feature is absent in living-sewage pollution load. Crop pollution has shown a decreasing trend since 1997 because of the increased per capita income of farmers. Livestock-breeding pollution load reached its turning point when the per capita income of farmers reached 8386.74 RMB. Therefore, an increase in the per capita income of farmers corresponds to an increase in the livestock-breeding pollution load in the Ningxia Yellow River irrigation area.

  8. Net load forecasting for high renewable energy penetration grids

    International Nuclear Information System (INIS)

    Kaur, Amanpreet; Nonnenmacher, Lukas; Coimbra, Carlos F.M.

    2016-01-01

    We discuss methods for net load forecasting and their significance for operation and management of power grids with high renewable energy penetration. Net load forecasting is an enabling technology for the integration of microgrid fleets with the macrogrid. Net load represents the load that is traded between the grids (microgrid and utility grid). It is important for resource allocation and electricity market participation at the point of common coupling between the interconnected grids. We compare two inherently different approaches: additive and integrated net load forecast models. The proposed methodologies are validated on a microgrid with 33% annual renewable energy (solar) penetration. A heuristics based solar forecasting technique is proposed, achieving skill of 24.20%. The integrated solar and load forecasting model outperforms the additive model by 10.69% and the uncertainty range for the additive model is larger than the integrated model by 2.2%. Thus, for grid applications an integrated forecast model is recommended. We find that the net load forecast errors and the solar forecasting errors are cointegrated with a common stochastic drift. This is useful for future planning and modeling because the solar energy time-series allows to infer important features of the net load time-series, such as expected variability and uncertainty. - Highlights: • Net load forecasting methods for grids with renewable energy generation are discussed. • Integrated solar and load forecasting outperforms the additive model by 10.69%. • Net load forecasting reduces the uncertainty between the interconnected grids.

  9. Design and performance of a 2-megawatt high voltage dc test load

    International Nuclear Information System (INIS)

    Horan, D.; Kustom, R.; Ferguson, M.

    1994-01-01

    A high-power water-cooled resistive load which simulates the electrical load characteristics of a high-power klystron, capable of a 2 MW dissipation at 95 kV DC, is designed and installed. The load utilizes wirewound resistor elements suspended inside G-11 insulated tubing contained within a single-wall 316 stainless steel pressure vessel with flanged elliptical heads. The vessel supplies a continuous flow of deionized water. Baffles fabricated from G-10 sheets support the tubing and promote water turbulence to maximize heat removal. A companion oil tank houses resistive filament and mod-anode power supply test loads, plus an electrical interlock system which provides protection from inadequate water flow, excessive oil temperature, and arcing in either the pressure vessel or oil tank. A secondary safety system consists of both hydrostatic and steam pressure relief valves on the pressure vessel. Power supply tests indicate the load simulates the electrical load characteristics of a high-power klystron to a degree sufficient to accurately performance-test the rf high voltage power supplies used at the Advanced Photon Source

  10. Selection and identification of air pollution-tolerant plants by air ...

    African Journals Online (AJOL)

    Mehdi

    2012-07-10

    Jul 10, 2012 ... taining the ecological balance by actively participating in the cycling of ... (APTI) and this performance rating, the most tolerant. *Corresponding author ... overall pollution load, leaving the air moderately free of pollutants (Rao ...

  11. A review of ion and metal pollutants in urban green water infrastructures.

    Science.gov (United States)

    Kabir, Md Imran; Daly, Edoardo; Maggi, Federico

    2014-02-01

    In urban environments, the breakdown of chemicals and pollutants, especially ions and metal compounds, can be favoured by green water infrastructures (GWIs). The overall aim of this review is to set the basis to model GWIs using deterministic approaches in contrast to empirical ones. If a better picture of chemicals and pollutant input and an improved understanding of hydrological and biogeochemical processes affecting these pollutants were known, GWIs could be designed to efficiently retain these pollutants for site-specific meteorological patterns and pollutant load. To this end, we surveyed the existing literature to retrieve a comprehensive dataset of anions and cations, and alkaline and transition metal pollutants incoming to urban environments. Based on this survey, we assessed the pollution load and ecological risk indexes for metals. The existing literature was then surveyed to review the metal retention efficiency of GWIs, and possible biogeochemical processes related to inorganic metal compounds were proposed that could be integrated in biogeochemical models of GWIs. © 2013.

  12. Pollution prevention applications in batch manufacturing operations

    Science.gov (United States)

    Sykes, Derek W.; O'Shaughnessy, James

    2004-02-01

    Older, "low-tech" batch manufacturing operations are often fertile grounds for gains resulting from pollution prevention techniques. This paper presents a pollution prevention technique utilized for wastewater discharge permit compliance purposes at a batch manufacturer of detergents, deodorants, and floor-care products. This manufacturer generated industrial wastewater as a result of equipment rinses required after each product batch changeover. After investing a significant amount of capital on end of pip-line wastewater treatment technology designed to address existing discharge limits, this manufacturer chose to investigate alternate, low-cost approaches to address anticipated new permit limits. Mass balances using spreadsheets and readily available formulation and production data were conducted on over 300 products to determine how each individual product contributed to the total wastewater pollutant load. These mass balances indicated that 22 products accounted for over 55% of the wastewater pollutant. Laboratory tests were conducted to determine whether these same products could accept their individual changeover rinse water as make-up water in formulations without sacrificing product quality. This changeover reuse technique was then implement at the plant scale for selected products. Significant reductions in wastewater volume (25%) and wastewater pollutant loading (85+%) were realized as a direct result of this approach.

  13. Responses of biofilm characteristics to variations in temperature and NH4(+)-N loading in a moving-bed biofilm reactor treating micro-polluted raw water.

    Science.gov (United States)

    Zhang, Shuangfu; Wang, Yayi; He, Weitao; Wu, Min; Xing, Meiyan; Yang, Jian; Gao, Naiyun; Yin, Daqiang

    2013-03-01

    A pilot-scale moving-bed biofilm reactor (MBBR) for biological treatment of micro-polluted raw water was operated over 400days to investigate the responses of biofilm characteristics and nitrification performance to variations in temperature and NH4(+)-N loading. The mean removal efficiency of NH4(+)-N in the MBBR reached 71.4±26.9%, and batch experiments were performed to study nitrification kinetics for better process understanding. Seven physical-chemical parameters, including volatile solids (VS), polysaccharides (PS) and phospholipids (PL) increased firstly, and then rapidly decreased with increasing temperature and NH4(+)-N loading, and properly characterized the attached biomass during biofilm development and detachment in the MBBR. The biofilm compositions were described by six ratios, e.g., PS/VS and PL/VS ratios showed different variation trends, indicating different responses of PS and PL to the changes in temperature and NH4(+)-N loading. Furthermore, fluorescent in situ hybridization (FISH) analysis revealed that increased NH4(+)-N loadings caused an enrichment of the nitrifying biofilm. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Using high complexity analysis to probe the evolution of organic aerosol during pollution events in Beijing

    Science.gov (United States)

    Hamilton, J.; Dixon, W.; Dunmore, R.; Squires, F. A.; Swift, S.; Lee, J. D.; Rickard, A. R.; Sun, Y.; Xu, W.

    2017-12-01

    There is increasing evidence that exposure to air pollution results in significant impacts on human health. In Beijing, home to over 20 million inhabitants, particulate matter levels are very high by international standards, with official estimates of an annual mean PM2.5 concentration in 2014 of 86 μg m-3, nearly 9 times higher than the WHO guideline. Changes in particle composition during pollution events will provide key information on sources and can be used to inform strategies for pollution mitigation and health benefits. The organic fraction of PM is an extremely complex mixture reflecting the diversity of sources to the atmosphere. In this study we attempt to harness the chemical complexity of OA by developing an extensive database of over 700 mass spectra, built using literature data and sources specific tracers (e.g. diesel emission characterisation experiments and SOA generated in chamber simulations). Using a high throughput analysis method (15 min), involving UHPLC coupled to Orbitrap mass spectrometry, chromatograms are integrated, compared to the library and a list of identified compounds produced. Purpose built software based on R is used to automatically produce time series, alongside common aerosol metrics and data visualisation techniques, dramatically reducing analysis times. Offline measurements of organic aerosol composition were made as part of the Sources and Emissions of Air Pollutants in Beijing project, a collaborative program between leading UK and Chinese research groups. Rather than studying only a small number of 24 hr PM samples, we collected 250 filters samples at a range of different time resolutions, from 30 minutes to 12 hours, depending on the time of day and PM loadings. In total 643 species were identified based on their elemental formula and retention time, with species ranging from C2-C22 and between 1-13 oxygens. A large fraction of the OA species observed were organosulfates and/or nitrates. Here we will present

  15. Extrinsic Cognitive Load Impairs Spoken Word Recognition in High- and Low-Predictability Sentences.

    Science.gov (United States)

    Hunter, Cynthia R; Pisoni, David B

    Listening effort (LE) induced by speech degradation reduces performance on concurrent cognitive tasks. However, a converse effect of extrinsic cognitive load on recognition of spoken words in sentences has not been shown. The aims of the present study were to (a) examine the impact of extrinsic cognitive load on spoken word recognition in a sentence recognition task and (b) determine whether cognitive load and/or LE needed to understand spectrally degraded speech would differentially affect word recognition in high- and low-predictability sentences. Downstream effects of speech degradation and sentence predictability on the cognitive load task were also examined. One hundred twenty young adults identified sentence-final spoken words in high- and low-predictability Speech Perception in Noise sentences. Cognitive load consisted of a preload of short (low-load) or long (high-load) sequences of digits, presented visually before each spoken sentence and reported either before or after identification of the sentence-final word. LE was varied by spectrally degrading sentences with four-, six-, or eight-channel noise vocoding. Level of spectral degradation and order of report (digits first or words first) were between-participants variables. Effects of cognitive load, sentence predictability, and speech degradation on accuracy of sentence-final word identification as well as recall of preload digit sequences were examined. In addition to anticipated main effects of sentence predictability and spectral degradation on word recognition, we found an effect of cognitive load, such that words were identified more accurately under low load than high load. However, load differentially affected word identification in high- and low-predictability sentences depending on the level of sentence degradation. Under severe spectral degradation (four-channel vocoding), the effect of cognitive load on word identification was present for high-predictability sentences but not for low

  16. Sample intake position and loading rates from nonpoint source pollution

    Science.gov (United States)

    McGuire, P. E.; Daniel, T. C.; Stoffel, D.; Andraski, B.

    1980-01-01

    Paired water samples were simultaneously activated from two different vertical positions within the approach section of a flow-control structure to determine the effect of sample intake position on nonpoint runoff parameter concentrations and subsequent event loads. Suspended solids (SS), total phosphorus (TP) and organic plus exchangeable nitrogen [(Or+Ex)-N] were consistently higher throughout each runoff event when sampled from the floor of the approach section as opposed to those samples taken at midstage. Dissolved molybdate reactive phosphorus (DMRP) and ammonium (NH4-N) concentrations did not appear to be significantly affected by the vertical difference in intake position. However, the nitrate plus nitrite nitrogen [(NO3+NO2)-N] concentrations were much higher when sampled from the midstage position. Although the concentration differences between the two methods were not appreciable, when evaluated in terms of event loads, discrepancies were evident for all parameters. Midstage sampling produced event loads for SS, TP, (Or + Ex)-N, DMRP, NH4-N, and (NO3+NO2)-N that were 44,39,35,80,71, and 181%, respectively, of floor sampling loads. Differences in loads between the two methods are attributed to the midstage position, sampling less of the bed load. The correct position will depend on the objective; however, such differences should be recognized during the design phase of the monitoring program.

  17. Traffic air pollution and oxidized LDL.

    Directory of Open Access Journals (Sweden)

    Lotte Jacobs

    Full Text Available BACKGROUND: Epidemiologic studies indirectly suggest that air pollution accelerates atherosclerosis. We hypothesized that individual exposure to particulate matter (PM derived from fossil fuel would correlate with plasma concentrations of oxidized low-density lipoprotein (LDL, taken as a marker of atherosclerosis. We tested this hypothesis in patients with diabetes, who are at high risk for atherosclerosis. METHODOLOGY/PRINCIPAL FINDINGS: In a cross-sectional study of non-smoking adult outpatients with diabetes we assessed individual chronic exposure to PM by measuring the area occupied by carbon in airway macrophages, collected by sputum induction and by determining the distance from the patient's residence to a major road, through geocoding. These exposure indices were regressed against plasma concentrations of oxidized LDL, von Willebrand factor and plasminogen activator inhibitor 1 (PAI-1. We could assess the carbon load of airway macrophages in 79 subjects (58 percent. Each doubling in the distance of residence from major roads was associated with a 0.027 µm(2 decrease (95% confidence interval (CI: -0.048 to -0.0051 in the carbon load of airway macrophages. Independently from other covariates, we found that each increase of 0.25 µm(2 [interquartile range (IQR] in carbon load was associated with an increase of 7.3 U/L (95% CI: 1.3 to 13.3 in plasma oxidized LDL. Each doubling in distance of residence from major roads was associated with a decrease of -2.9 U/L (95% CI: -5.2 to -0.72 in oxidized LDL. Neither the carbon load of macrophages nor the distance from residence to major roads, were associated with plasma von Willebrand factor or PAI-1. CONCLUSIONS: The observed positive association, in a susceptible group of the general population, between plasma oxidized LDL levels and either the carbon load of airway macrophages or the proximity of the subject's residence to busy roads suggests a proatherogenic effect of traffic air pollution.

  18. Evaluation of Land Use, Land Management and Soil Conservation Strategies to Reduce Non-Point Source Pollution Loads in the Three Gorges Region, China.

    Science.gov (United States)

    Strehmel, Alexander; Schmalz, Britta; Fohrer, Nicola

    2016-11-01

    The construction of the Three Gorges Dam in China and the subsequent impoundment of the Yangtze River have induced a major land use change in the Three Gorges Reservoir Region, which fosters increased inputs of sediment and nutrients from diffuse sources into the water bodies. Several government programs have been implemented to mitigate high sediment and nutrient loads to the reservoir. However, institutional weaknesses and a focus on economic development have so far widely counteracted the effectiveness of these programs. In this study, the eco-hydrological model soil and water assessment tool is used to assess the effects of changes in fertilizer amounts and the conditions of bench terraces in the Xiangxi catchment in the Three Gorges Reservoir Region on diffuse matter releases. With this, the study aims at identifying efficient management measures, which should have priority. The results show that a reduction of fertilizer amounts cannot reduce phosphorus loads considerably without inhibiting crop productivity. The condition of terraces in the catchment has a strong impact on soil erosion and phosphorus releases from agricultural areas. Hence, if economically feasible, programmes focusing on the construction and maintenance of terraces in the region should be implemented. Additionally, intercropping on corn fields as well as more efficient fertilization schemes for agricultural land were identified as potential instruments to reduce diffuse matter loads further. While the study was carried out in the Three Gorges Region, its findings may also beneficial for the reduction of water pollution in other mountainous areas with strong agricultural use.

  19. Evaluation of Land Use, Land Management and Soil Conservation Strategies to Reduce Non-Point Source Pollution Loads in the Three Gorges Region, China

    Science.gov (United States)

    Strehmel, Alexander; Schmalz, Britta; Fohrer, Nicola

    2016-11-01

    The construction of the Three Gorges Dam in China and the subsequent impoundment of the Yangtze River have induced a major land use change in the Three Gorges Reservoir Region, which fosters increased inputs of sediment and nutrients from diffuse sources into the water bodies. Several government programs have been implemented to mitigate high sediment and nutrient loads to the reservoir. However, institutional weaknesses and a focus on economic development have so far widely counteracted the effectiveness of these programs. In this study, the eco-hydrological model soil and water assessment tool is used to assess the effects of changes in fertilizer amounts and the conditions of bench terraces in the Xiangxi catchment in the Three Gorges Reservoir Region on diffuse matter releases. With this, the study aims at identifying efficient management measures, which should have priority. The results show that a reduction of fertilizer amounts cannot reduce phosphorus loads considerably without inhibiting crop productivity. The condition of terraces in the catchment has a strong impact on soil erosion and phosphorus releases from agricultural areas. Hence, if economically feasible, programmes focusing on the construction and maintenance of terraces in the region should be implemented. Additionally, intercropping on corn fields as well as more efficient fertilization schemes for agricultural land were identified as potential instruments to reduce diffuse matter loads further. While the study was carried out in the Three Gorges Region, its findings may also beneficial for the reduction of water pollution in other mountainous areas with strong agricultural use.

  20. Temporal-spatial patterns of three types of pesticide loadings in a middle-high latitude agricultural watershed.

    Science.gov (United States)

    Ouyang, Wei; Cai, Guanqing; Tysklind, Mats; Yang, Wanyin; Hao, Fanghua; Liu, Hongbin

    2017-10-01

    Pesticide loadings to watersheds increase during agricultural development and may vary in accordance with different crop types and seasons. High pesticide loadings can potentially result in polluted stream water. The objective of this study was to determine the pesticide loadings and concentrations of three typical pesticides (atrazine, oxadiazon, and isoprothiolane) in river water from a middle-high latitude agricultural watershed in northern China. During this study, we evaluated the watershed pesticide loss patterns for two crop types over three decades. For this purpose, we integrated data from field investigations, laboratory experiments, and modeling simulations involving a distributed hydrological solute transport model (Soil and Water Assessment Tool, SWAT). SWAT was employed to compare the temporal-spatial fate and behaviors of atrazine, oxadiazon, and isoprothiolane from 1990 to 2014 in a watershed area amounting to 141.5 km 2 . The results showed that the three pesticides could be detected at different locations throughout the watershed, and isoprothiolane was detected at the maximum value of 1.082 μg/L in surface runoff of paddy land. The temporal trend for the yearly loading of atrazine decreased slightly over time, but the trends for oxadiazon and isoprothiolane increased markedly over an 18-year analysis period. In regard to the pesticide concentrations in water, atrazine was associated with the largest value of nearly 1.4 μg/L. July and August were the found to be prime periods for pesticide loss from paddy land, and the biggest monthly loss of atrazine from dryland appeared in June. Under similar usage conditions, isoprothiolane loading from paddy fields ranked as the largest one among the three types of pesticides and reached up to 17 g/ha. Limited monitoring data were useful for validating the model, which yielded valuable temporal-spatial data on the fate of pesticides in this watershed. With the expansion of paddy rice cultivation, risks

  1. Analysis of snow-cap pollution for air quality assessment in the vicinity of an oil refinery.

    Science.gov (United States)

    Krastinyte, Viktorija; Baltrenaite, Edita; Lietuvninkas, Arvydas

    2013-01-01

    Snow-cap can be used as a simple and effective indicator of industrial air pollution. In this study snow-cap samples were collected from 11 sites located in the vicinity of an oil refinery in Mazeikiai, a region in the north-west of Lithuania, in the winter of 2011. Analysis of snowmelt water and snow-dust was used to determine anthropogenic pollutants such as: sulphates and chlorides, nitrites, nitrates, ammonium nitrogen, total carbon, total nitrogen; heavy metals: lead (Pb), copper (Cu), chromium (Cr), cadmium (Cd). Concentrations of heavy metals in snow-dust were detected thousands of times higher than those in the snowmelt water. In this study, analysis of heavy metal concentration was conducted considering different distances and the wind direction within the impact zone of the oil refinery. The sequence of heavy metals according to their mean concentrations in the snow-dust samples was the following: Pb > Cr > Cu > Cd. Heavy metals highly correlated among each other. The load of snow-dust was evaluated to determine the pollution level in the study area. The highest daily load of snow-dust was 45.81 +/- 12.35 mg/m2 in the north-western direction from the oil refinery. According to classification of the daily load of snow-dust a lower than medium-risk level of pollution was determined in the vicinity of the oil refinery.

  2. Highly Polluted Wastewaters Treatment by Improved Dissolved Air Flotation Technology

    Science.gov (United States)

    Moga, I. C.; Covaliu, C. I.; Matache, M. G.; Doroftei, B. I.

    2017-06-01

    Numerous investigations are oriented towards the development of new wastewater treatment technologies, having high efficiencies for removing even low concentrations of pollutants found in water. These efforts were determined by the destroyer impact of the pollutants to the environment and human’s health. For this reason this paper presents our study concerning an improved dissolved air flotation technology for wastewater treatment. There is described a dissolved air flotation (DAF) installation composed by two equipments: pressurized capsule and lamellar settling. Also, there are presented some advantages of using nanoparticles as flotation collectors.

  3. Model predictions of ambient pollution concentration | Olaniyan ...

    African Journals Online (AJOL)

    The results show that the emission loads of the pollutants associated with the use of industrial boiler and power generating plant are in decreasing order of magnitude as NOx > CO > TSP > SO2 > VOC > SO,sub>3 and NOx > TSP > CO > HC > SO2 respectively. The emission load of SO2 is 74.6% in power generating plant, ...

  4. High rate loading tests and impact tests of concrete and reinforcement

    International Nuclear Information System (INIS)

    Takeda, J.I.; Tachikawa, H.; Fujimoto, K.

    1982-01-01

    The responses of reinforced concrete structural members and structures subjected to impact or impulsive loadings are affected by the behavior of constituent concrete and reinforcement which are the synthesis of the rate effects and the contribution of propagating stress waves of them. The rate effects and the contribution of stress waves do not have the same tendency in the variation of magnitude of them with speed of impact or impulsive loadings. Therefore the rate effects, mentioned above, should be obtained by the tests minimized the effect of stress waves (high rate loading test). This paper deals with the testing techniques with high rate loadings and impact, and also reports the main results of these tests. (orig.) [de

  5. Is smog innocuous? Air pollution and cardiovascular disease

    Directory of Open Access Journals (Sweden)

    Sundeep Mishra

    2017-07-01

    Full Text Available Air pollution is a significant environmental and health hazard. Earlier studies had examined the adverse health effects associated with short- and long-term exposure to particulate matter on respiratory disease. However, later studies demonstrated that was actually cardiovascular disease that accounted for majority of mortality. Furthermore, it was not gaseous pollutants like oxides of nitrate, sulfur, carbon mono-oxide or ozone but the particulate matter or PM, of fine or coarse size (PM2.5 and PM10 which was linearly associated with mortality; PM2.5 with long term and PM10 with short term. Several cardiovascular diseases are associated with pollution; acute myocardial infarction, heart failure, cardiac arrhythmias, atherosclerosis and cardiac arrest. The ideal way to address this problem is by adhering to stringent environmental standards of pollutants but some individual steps like choosing to stay indoors (on high pollution days, reducing outdoor air permeation to inside, purifying indoor air using air filters, and also limiting outdoor physical activity near source of air pollution can help. Nutritional anti-oxidants like statins or Mediterranean diet, and aspirin have not been associated with reduced risk but specific nutritional agents like broccoli, cabbage, cauliflower or brussels sprouts, fish oil supplement may help. Use of face-mask has been controversial but may be useful if particulate matter load is higher.

  6. Is smog innocuous? Air pollution and cardiovascular disease.

    Science.gov (United States)

    Mishra, Sundeep

    Air pollution is a significant environmental and health hazard. Earlier studies had examined the adverse health effects associated with short- and long-term exposure to particulate matter on respiratory disease. However, later studies demonstrated that was actually cardiovascular disease that accounted for majority of mortality. Furthermore, it was not gaseous pollutants like oxides of nitrate, sulfur, carbon mono-oxide or ozone but the particulate matter or PM, of fine or coarse size (PM 2.5 and PM 10 ) which was linearly associated with mortality; PM 2.5 with long term and PM 10 with short term. Several cardiovascular diseases are associated with pollution; acute myocardial infarction, heart failure, cardiac arrhythmias, atherosclerosis and cardiac arrest. The ideal way to address this problem is by adhering to stringent environmental standards of pollutants but some individual steps like choosing to stay indoors (on high pollution days), reducing outdoor air permeation to inside, purifying indoor air using air filters, and also limiting outdoor physical activity near source of air pollution can help. Nutritional anti-oxidants like statins or Mediterranean diet, and aspirin have not been associated with reduced risk but specific nutritional agents like broccoli, cabbage, cauliflower or brussels sprouts, fish oil supplement may help. Use of face-mask has been controversial but may be useful if particulate matter load is higher. Copyright © 2017. Published by Elsevier B.V.

  7. Long-Term Hydrologic Impact Assessment of Non-point Source Pollution Measured Through Land Use/Land Cover (LULC) Changes in a Tropical Complex Catchment

    Science.gov (United States)

    Abdulkareem, Jabir Haruna; Sulaiman, Wan Nor Azmin; Pradhan, Biswajeet; Jamil, Nor Rohaizah

    2018-03-01

    The contribution of non-point source pollution (NPS) to the contamination of surface water is an issue of growing concern. Non-point source (NPS) pollutants are of various types and altered by several site-specific factors making them difficult to control due to complex uncertainties involve in their behavior. Kelantan River basin, Malaysia is a tropical catchment receiving heavy monsoon rainfall coupled with intense land use/land cover (LULC) changes making the area consistently flood prone thereby deteriorating the surface water quality in the area. This study was conducted to determine the spatio-temporal variation of NPS pollutant loads among different LULC changes and to establish a NPS pollutant loads relationships among LULC conditions and sub-basins in each catchment. Four pollutants parameters such as total suspended solids (TSS), total phosphorus (TP), total nitrogen (TN) and ammonia nitrogen (AN) were chosen with their corresponding event mean concentration values (EMC). Soil map and LULC change maps corresponding to 1984, 2002 and 2013 were used for the calculation of runoff and NPS pollutant loads using numeric integration in a GIS environment. Analysis of Variance (ANOVA) was conducted for the comparison of NPS pollutant loads among the three LULC conditions used and the sub-basins in each catchment. The results showed that the spatio-temporal variation of pollutant loads in almost all the catchments increased with changes in LULC condition as one moves from 1984 to 2013, with 2013 LULC condition found as the dominant in almost all cases. NPS pollutant loads among different LULC changes also increased with changes in LULC condition from 1984 to 2013. While urbanization was found to be the dominant LULC change with the highest pollutant load in all the catchments. Results from ANOVA reveals that statistically most significant (p < 0.05) pollutant loads were obtained from 2013 LULC conditions, while statistically least significant (p < 0.05) pollutant

  8. Nutrient and metal pollution of the eastern Gulf of Finland coastline: Sediments, macroalgae, microbiota

    International Nuclear Information System (INIS)

    Gubelit, Yulia; Polyak, Yulia; Dembska, Grazyna; Pazikowska-Sapota, Grazyna; Zegarowski, Lukasz; Kochura, Dmitry; Krivorotov, Denis; Podgornaya, Elena; Burova, Olga; Maazouzi, Chafik

    2016-01-01

    The anthropogenic pollution along the coastline of the eastern Gulf of Finland was studied through a range of methods, including analyses of metal contamination in water, surface sediments, accumulated algal biomass and its correlation with resistant microbiota. According to concentrations, the main pollutants in water were copper and manganese. Influence of Nuclear Power Plant was remarkable in adjacent areas and was expressed in high concentrations of molybdenum, nickel, copper and other elements in the water. Relatively high concentrations of copper, lead and zinc were found in sediments. Microbial tolerance appeared to be correlated with the concentration of the metals in sediments. Higher tolerance levels were found in sediment samples from more polluted stations. Macroalgae, which were massively developed in the coastal zone, had shown high level of metal bioaccumulation. Analyses of carbon, nitrogen and phosphorus content of algal tissues allowed the estimation of additional nutrient loading from accumulated decaying algal biomass on the coastal zone of the eastern Gulf of Finland. Mass development of algae in coastal area may contribute to accumulation of organic matter and associated metals. In our study the highest metal concentrations in sediments were found at the sites with dense and continuous layer of fresh and decaying macroalgal biomass, accompanied by hypoxic conditions. Also our study has shown that accumulated biomass may be a significant source of nutrients in the coastal ecosystem. - Highlights: • We studied heavy metal pollution in the coastline of the eastern Gulf of Finland. • Sediments, water, mass macroalgae and microbiota were included into analyses. • Eutrophication and nutrient loading remain the main problem of the studied area. • Macroalgae contribute to accumulation of organic matter, nutrient, and heavy metal. • Pollution in the studied area is caused by a combination of different factors.

  9. Nutrient and metal pollution of the eastern Gulf of Finland coastline: Sediments, macroalgae, microbiota

    Energy Technology Data Exchange (ETDEWEB)

    Gubelit, Yulia, E-mail: Gubelit@list.ru [Zoological Institute of the Russian Academy of Sciences, St. Petersburg (Russian Federation); Polyak, Yulia [Scientific Research Center for Ecological Safety of the Russian Academy of Sciences, St. Petersburg (Russian Federation); Dembska, Grazyna; Pazikowska-Sapota, Grazyna; Zegarowski, Lukasz [Maritime Institute in Gdansk, Department of Environmental Protection, Gdansk (Poland); Kochura, Dmitry; Krivorotov, Denis; Podgornaya, Elena; Burova, Olga [Research Institute of Hygiene, Occupational Pathology and Human Ecology (RIHOPHE), Federal Medical Biological Agency, St. Petersburg (Russian Federation); Maazouzi, Chafik [Université Claude Bernard Lyon 1, Laboratoire d' Écologie des Hydrosystèmes Naturels et Anthropisés (LEHNA), Lyon (France)

    2016-04-15

    The anthropogenic pollution along the coastline of the eastern Gulf of Finland was studied through a range of methods, including analyses of metal contamination in water, surface sediments, accumulated algal biomass and its correlation with resistant microbiota. According to concentrations, the main pollutants in water were copper and manganese. Influence of Nuclear Power Plant was remarkable in adjacent areas and was expressed in high concentrations of molybdenum, nickel, copper and other elements in the water. Relatively high concentrations of copper, lead and zinc were found in sediments. Microbial tolerance appeared to be correlated with the concentration of the metals in sediments. Higher tolerance levels were found in sediment samples from more polluted stations. Macroalgae, which were massively developed in the coastal zone, had shown high level of metal bioaccumulation. Analyses of carbon, nitrogen and phosphorus content of algal tissues allowed the estimation of additional nutrient loading from accumulated decaying algal biomass on the coastal zone of the eastern Gulf of Finland. Mass development of algae in coastal area may contribute to accumulation of organic matter and associated metals. In our study the highest metal concentrations in sediments were found at the sites with dense and continuous layer of fresh and decaying macroalgal biomass, accompanied by hypoxic conditions. Also our study has shown that accumulated biomass may be a significant source of nutrients in the coastal ecosystem. - Highlights: • We studied heavy metal pollution in the coastline of the eastern Gulf of Finland. • Sediments, water, mass macroalgae and microbiota were included into analyses. • Eutrophication and nutrient loading remain the main problem of the studied area. • Macroalgae contribute to accumulation of organic matter, nutrient, and heavy metal. • Pollution in the studied area is caused by a combination of different factors.

  10. Loading Effect on Tire Noise Radiation

    OpenAIRE

    Cao, Rui; Bolton, J Stuart

    2016-01-01

    Noise radiated by tires is a prominent noise pollution source and it is affected by many different parameters. Here, the effect of static load on tire noise radiation in a laboratory environment was investigated. The measurement was conducted by using the Tire Pavement Testing Apparatus (TPTA), on which a loaded tire can be run at speeds up to 50 km/hr; the tire noise was measured using a nearfield microphone method. The tire loading was varied from 500 to 900 pounds, and several different co...

  11. High thermal load component

    International Nuclear Information System (INIS)

    Fuse, Toshiaki; Tachikawa, Nobuo.

    1996-01-01

    A cooling tube made of a pure copper is connected to the inner portion of an armour (heat resistant member) made of an anisotropic carbon/carbon composite (CFC) material. The CFC material has a high heat conductivity in longitudinal direction of fibers and has low conductivity in perpendicular thereto. Fibers extending in the armour from a heat receiving surface just above the cooling tube are directly connected to the cooling tube. A portion of the fibers extending from a heat receiving surface other than portions not just above the cooling tube is directly bonded to the cooling tube. Remaining fibers are disposed so as to surround the cooling tube. The armour and the cooling tube are soldered using an active metal flux. With such procedures, high thermal load components for use in a thermonuclear reactor are formed, which are excellent in a heat removing characteristic and hardly causes defects such as crackings and peeling. (I.N.)

  12. Assessing the pollution risk of soil Chromium based on loading capacity of paddy soil at a regional scale

    Science.gov (United States)

    Qu, Mingkai; Li, Weidong; Zhang, Chuanrong; Huang, Biao; Zhao, Yongcun

    2015-01-01

    The accumulation of a trace metal in rice grain is not only affected by the total concentration of the soil trace metal, but also by crop variety and related soil properties, such as soil pH, soil organic matter (SOM) and so on. However, these factors were seldom considered in previous studies on mapping the pollution risk of trace metals in paddy soil at a regional scale. In this study, the spatial nonstationary relationships between rice-Cr and a set of perceived soil properties (soil-Cr, soil pH and SOM) were explored using geographically weighted regression; and the relationships were then used for calculating the critical threshold (CT) of soil-Cr concentration that may ensure the concentration of rice-Cr being below the permissible limit. The concept of “loading capacity” (LC) for Cr in paddy soil was then defined as the difference between the CT and the real concentration of Cr in paddy soil, so as to map the pollution risk of soil-Cr to rice grain and assess the risk areas in Jiaxing city, China. Compared with the information of the concentration of the total soil-Cr, such results are more valuable for spatial decision making in reducing the accumulation of rice-Cr at a regional scale. PMID:26675587

  13. Assessing the pollution risk of soil Chromium based on loading capacity of paddy soil at a regional scale.

    Science.gov (United States)

    Qu, Mingkai; Li, Weidong; Zhang, Chuanrong; Huang, Biao; Zhao, Yongcun

    2015-12-17

    The accumulation of a trace metal in rice grain is not only affected by the total concentration of the soil trace metal, but also by crop variety and related soil properties, such as soil pH, soil organic matter (SOM) and so on. However, these factors were seldom considered in previous studies on mapping the pollution risk of trace metals in paddy soil at a regional scale. In this study, the spatial nonstationary relationships between rice-Cr and a set of perceived soil properties (soil-Cr, soil pH and SOM) were explored using geographically weighted regression; and the relationships were then used for calculating the critical threshold (CT) of soil-Cr concentration that may ensure the concentration of rice-Cr being below the permissible limit. The concept of "loading capacity" (LC) for Cr in paddy soil was then defined as the difference between the CT and the real concentration of Cr in paddy soil, so as to map the pollution risk of soil-Cr to rice grain and assess the risk areas in Jiaxing city, China. Compared with the information of the concentration of the total soil-Cr, such results are more valuable for spatial decision making in reducing the accumulation of rice-Cr at a regional scale.

  14. Characteristic study of high-Tc superconducting maglev under side-loading

    International Nuclear Information System (INIS)

    Wang Wei; Wang Jiasu; Liu Wei; Zheng Jun; Lin Qunxu; Pan Siting; Deng Zigang; Ma Guangtong; Wang Suyu

    2009-01-01

    In practical application of High-T c Superconducting (HTS) maglev, slant is an observable defect. It was caused by constantly one side on and off the vehicle by passengers. So far, this phenomenon has not been reported yet. In order to understand its influence on the stability of the HTS maglev, we experimentally studied the dynamic characteristic and slant effect of HTS maglev under center-load and side-load. It was found that load destabilizes the vehicle, and the side-load can obviously slant the vehicle body. In the end, the pre-load method was proposed to enhance the dynamic stability and suppress the slant, which proved to be considerably effective. These results are critical in practical running of HTS maglev

  15. Impact Assessment of Atmospheric Dust on Foliage Pigments and Pollution Resistances of Plants Grown Nearby Coal Based Thermal Power Plants.

    Science.gov (United States)

    Hariram, Manisha; Sahu, Ravi; Elumalai, Suresh Pandian

    2018-01-01

    Plant species grown in the vicinity of thermal power plants (TPP) are one of the immobile substrates to sink most of the pollutants emitted from their stacks. The continuous exposure of toxic pollutants to these plants may affect their resistances and essential biochemical's concentrations. In the present study, we estimated the impact of dust load generated by a TPPs to plant's dust retention capacity and pollution resistances (APTI and API). The observed ambient air quality index (AQI) showed that the surroundings of TPPs are in the severe air pollution category. Observed AQI was greater than 100 in the surrounding area of TPP. The mean dust load on plant foliage was significantly greater in the polluted site compared with the control site: 4.45 ± 1.96 versus 1.38 ± 0.41 mg cm -2 . Nearby, TPP highest and lowest dust load were founded in F. benghalensis (7.58 ± 0.74) and F. religiosa (2.25 ± 0.12 mg cm -2 ) respectively. Analysis revealed the strong negative correlation between dust load and essential pigments of foliage, such as chlorophyll content, carotenoids, pH of foliage extract, and relative water content. Conversely, strong positive correlation was observed with the ascorbic acid content of plant species. Correlation and percentage change analysis in ascorbic acid content for the polluted site against the control site showed the adverse impact on plants due to dust load. Based on their responses to dust pollution, A. scholaris, P. longifolia, and M. indica were observed as most suitable plant species. Estimation of DRC, chlorophyll a/b ratio, APTI and API revealed the A. scholaris, F. benghalensis, P. longifolia, and M. indica as the most suitable plant species for green belt formation. The high gradation was obtained in A. scholaris, F. benghalensis, P. longifolia, and M. indica for opted parameters and showed their most suitability for green belt formation. Salient features of the present study provide useful evidences to estimate the

  16. Lie construction affects information storage under high memory load condition.

    Directory of Open Access Journals (Sweden)

    Yuqiu Liu

    Full Text Available Previous studies indicate that lying consumes cognitive resources, especially working memory (WM resources. Considering the dual functions that WM might play in lying: holding the truth-related information and turning the truth into lies, the present study examined the relationship between the information storage and processing in the lie construction. To achieve that goal, a deception task based on the old/new recognition paradigm was designed, which could manipulate two levels of WM load (low-load task using 4 items and high-load task using 6 items during the deception process. The analyses based on the amplitude of the contralateral delay activity (CDA, a proved index of the number of representations being held in WM, showed that the CDA amplitude was lower in the deception process than that in the truth telling process under the high-load condition. In contrast, under the low-load condition, no CDA difference was found between the deception and truth telling processes. Therefore, we deduced that the lie construction and information storage compete for WM resources; when the available WM resources cannot meet this cognitive demand, the WM resources occupied by the information storage would be consumed by the lie construction.

  17. Lie construction affects information storage under high memory load condition.

    Science.gov (United States)

    Liu, Yuqiu; Wang, Chunjie; Jiang, Haibo; He, Hongjian; Chen, Feiyan

    2017-01-01

    Previous studies indicate that lying consumes cognitive resources, especially working memory (WM) resources. Considering the dual functions that WM might play in lying: holding the truth-related information and turning the truth into lies, the present study examined the relationship between the information storage and processing in the lie construction. To achieve that goal, a deception task based on the old/new recognition paradigm was designed, which could manipulate two levels of WM load (low-load task using 4 items and high-load task using 6 items) during the deception process. The analyses based on the amplitude of the contralateral delay activity (CDA), a proved index of the number of representations being held in WM, showed that the CDA amplitude was lower in the deception process than that in the truth telling process under the high-load condition. In contrast, under the low-load condition, no CDA difference was found between the deception and truth telling processes. Therefore, we deduced that the lie construction and information storage compete for WM resources; when the available WM resources cannot meet this cognitive demand, the WM resources occupied by the information storage would be consumed by the lie construction.

  18. European Commission funded program on the impact of air pollution on population health: the example of HEalth Risk from Environmental Pollution Levels in Urban Systems (HEREPLUS Project

    Directory of Open Access Journals (Sweden)

    Giuseppe La Torre

    2016-06-01

    Full Text Available HEalth Risk from Environmental Pollution Levels in Urban Systems (HEREPLUS project has been thought and carried out to fill some of the identified gaps in the evidence base and develop and apply an integrated methodology for assessing and quantifying the health risk associated to outdoor pollution exposure and for investigating the potential mitigating role of urban green. Results of HEREPLUS have demonstrated that these are no watertight compartments and that some issues should be tackled in an integrated approach. For instance, benefits from a proper selection of vegetation species in a city could be assessed in terms of load of pollutants removed from the atmosphere, and furthermore this data translated into health benefits. Additionally, health outcomes could be better interpreted in terms of a spatial analysis that previously had defined the high risk areas associated to a specific pollutant and, in consequence, action plans can be defined taking into account this geo-referenced information.

  19. Primary organic pollutants in New Zealand urban aerosol in winter during high PM1 episodes

    International Nuclear Information System (INIS)

    Krivacsy, Zoltan; Blazso, Marianne; Shooter, David

    2006-01-01

    In the two biggest New Zealand cities, Auckland and Christchurch, the mass concentration of the PM 1 atmospheric aerosol can exceed the 50 μg m -3 24 h health guideline in winter. This high pollution level is thought to be caused mainly by old-fashioned domestic heating systems based on wood combustion. Therefore the chemistry of the carbonaceous aerosol has been investigated in several high-pollution level urban situations in order to assess the origin of the pollution. All the high concentration organic tracers, including levoglucosan and dehydroabietic acid, were characteristic for biomass burning. The findings have confirmed via advanced chemical analytical methods that domestic heating can be the main contributor to the high level of wintertime pollution, especially in Christchurch. The results are of great importance in supporting the ambition of authorities and environmental associations to change the domestic heating regimes. - PM 1 aerosol concentrations can exceed air quality guidelines during winter in Christchurch, New Zealand

  20. An inverted-geometry, high voltage polarized electron gun with UHV load lock

    International Nuclear Information System (INIS)

    Breidenbach, M.; Foss, M.; Hodgson, J.; Kulikov, A.; Odian, A.; Putallaz, G.; Rogers, H.; Schindler, R.; Skarpaas, K.; Zolotorev, M.

    1994-01-01

    The design of a high voltage electron source with a GaAs photocathode and a load lock system is described. The inverted high voltage structure of the gun permits a compact and simple design. Test results demonstrate that the load lock system provides a reliable way to achieve high quantum efficiency of the photocathode in a high voltage device. ((orig.))

  1. Fourier Transform Infrared Spectroscopy Analysis Of Oil Of Menthaarvensis Grown At Sites Varying With Vehicular Traffic Loads In Lucknow City, India

    Directory of Open Access Journals (Sweden)

    Nidhi Prakash

    2013-12-01

    Full Text Available The demand of the essential oil of mint species; widely used in food, pharmaceutical and cosmetic industries, is growing throughout the world. Owing its significance, it was felt important to know the changes in chemical characteristics of the oil, if any, for economic value when the crop of Mentha is grown near highways, railway tracks or areas having heavy traffic loads. To assess the effect of vehicular emissions on menthol (mint oil, transfer experiment study was conducted. Firstly, within the municipal premises of Lucknow city, five sites (Road stretches were identified based on survey of Lucknow city and the available data on air pollution loads. Sites were selected which were differing from each other significantly in terms of the number of vehicles (source of pollution plying on them but were quite similar to each other in other eco-physiological factors. On the select sites equal number of potted Menthaarvensis plants of the same age, height and vigour of saccham variety obtained from CSIR-CIMAP was kept to get exposed to auto-exhaust pollutants for one year. Irrigation regime at all sites was kept uniform to avoid the influence of any other variable other than vehicular emissions. An analysis of hydro-distillated essential oil of Menthaarvensis variety Sascham under FTIR (Fourier Transform Infrared Spectroscopy revealed some qualitative changes in the organic-compounds of the oil from plants grown at sites of Lucknow city loaded with high vehicular load (auto-exhaust pollutants over plants kept under relatively pollution free site. Several indicator bands that are pertained to functional groups represent chemical components or metabolic products. The quantity of the peppermint oil extracted from plants of site having highest traffic loads, in turn maximum ambient pollutants (NO2, SO2, O3, SPM & RSPM was also found less as compared to plants grown in less polluted site. International Journal of Environment, Volume-2, Issue-1, Sep

  2. Energy efficiency indicators for high electric-load buildings

    Energy Technology Data Exchange (ETDEWEB)

    Aebischer, Bernard; Balmer, Markus A.; Kinney, Satkartar; Le Strat, Pascale; Shibata, Yoshiaki; Varone, Frederic

    2003-06-01

    Energy per unit of floor area is not an adequate indicator for energy efficiency in high electric-load buildings. For two activities, restaurants and computer centres, alternative indicators for energy efficiency are discussed.

  3. Carry-over of pollutants from the atmosphere and on forest soil pollution in the ARGE ALP and ALPEN-ADRIA countries. Proceedings

    International Nuclear Information System (INIS)

    Kirchner, M.; Roesel, K.; Reuther, M.

    1993-11-01

    The issue of the pollution of the alpine region, especially the mountain forest ecosystem which, - together with some additional subject matters and issues constitutes the main issue of this conference and is, of course an ecological and economical issue of some urgency and an area where several problems compete with one another. This ecosystem is very sensitive both in terms of location and climate and in terms of the additional loads created by road traffic, tourism, agriculture and forestry. High precipitation in form of rain, fog and snow in the alpine regions means that air-borne pollutants from other areas can be deposited in large amounts. Higher mountaineous regions are especially prone to the generation of photooxidants which represent another potential of stress and danger for the forests. (orig./EW) [de

  4. Analyses of divertor high heat-flux components on thermal and electromagnetic loads

    Energy Technology Data Exchange (ETDEWEB)

    Araki, M.; Kitamura, K.; Suzuki, S. [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Urata, K. [Mitsubishi Geavy Industries Ltd., 2-5-1, Marunouchi,Chiyoda-ku, Tokyo 100 (Japan)

    1998-09-01

    In the International Thermonuclear Experimental Reactor (ITER), the divertor high heat-flux components are subjected not to only severe heat and particle loads, but also to large electromagnetic loads during reactor operation. A great deal of R and D has been carried out throughout the world with regard to the design of robust high heat-flux components. Based on R and D results, small and intermediate size mock-ups constructed from various armor tile materials have been successfully developed with respect to a thermomechanical point of view. However, little analysis has been carried out with regard to the elastic stresses induced with in the high heat-flux components via the electromagnetic loads during a plasma disruption. Furthermore, past research has only considered thermomechanical and electromagnetic loadings separately and uncoupled. Therefore, a systematic analysis of the combined effects of thermomechanical and electromagnetic loadings has been performed, with the analytical results assessed by ASME section 3 evaluation code. (orig.) 20 refs.

  5. Analyses of divertor high heat-flux components on thermal and electromagnetic loads

    International Nuclear Information System (INIS)

    Araki, M.; Kitamura, K.; Suzuki, S.

    1998-01-01

    In the International Thermonuclear Experimental Reactor (ITER), the divertor high heat-flux components are subjected not to only severe heat and particle loads, but also to large electromagnetic loads during reactor operation. A great deal of R and D has been carried out throughout the world with regard to the design of robust high heat-flux components. Based on R and D results, small and intermediate size mock-ups constructed from various armor tile materials have been successfully developed with respect to a thermomechanical point of view. However, little analysis has been carried out with regard to the elastic stresses induced with in the high heat-flux components via the electromagnetic loads during a plasma disruption. Furthermore, past research has only considered thermomechanical and electromagnetic loadings separately and uncoupled. Therefore, a systematic analysis of the combined effects of thermomechanical and electromagnetic loadings has been performed, with the analytical results assessed by ASME section 3 evaluation code. (orig.)

  6. Gearbox Reliability Collaborative Investigation of High-Speed-Shaft Bearing Loads

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Guo, Yi [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-06-01

    The loads and contact stresses in the bearings of the high speed shaft section of the Gearbox Reliability Collaborative gearbox are examined in this paper. The loads were measured though strain gauges installed on the bearing outer races during dynamometer testing of the gearbox. Loads and stresses were also predicted with a simple analytical model and higher-fidelity commercial models. The experimental data compared favorably to each model, and bearing stresses were below thresholds for contact fatigue and axial cracking.

  7. Assessing water pollution level and gray water footprint of anthropogenic nitrogen in agricultural system

    Science.gov (United States)

    Huang, Guorui; Chen, Han; Yu, Chaoqing

    2017-04-01

    Water pollution has become a global problem which is one of the most critical issues of today's water treatment. At a spatial resolution of 10km, we use the DeNitrification-DeComposition (DNDC) model to simulate the biogeochemical processes for major cropping systems from 1955 to 2014, estimate the anthropogenic nitrogen loads to fresh, and calculate the resultant grey water footprints and N-related water pollution level in China. The accumulated annual Nitrogen loads to fresh from agricultural system is 0.38Tg in 1955 and 4.42Tg in 2014, while the grey water footprints vary from 1.53 billion m3 to 17.67 billion m3, respectively. N loads in north of China contributes much more on the N leaching because of the high fertilizer but in south of China, it is mainly focused on the N runoff because of the heavy rain. There are more than 25% of grids with WPL>1 (exceed the water capacity of assimilation), which is mainly located on the North China Plain.

  8. Water pollution by non-radioactive materials

    International Nuclear Information System (INIS)

    Dickenbrok, G.

    1974-01-01

    Water is in constant circulation from the ocean to the earth's atmosphere and back to the ocean. In the course of this cycle, the composition of the water is altered by natural and human influences. Depending on the prevailing conditions, the water may contain solute gases, undissolved substances, inorganic salts, organic compounds, and microorganisms of varying types and concentrations. Many of these substances are known to pollute the water and thus to threaten its various uses. Emitting sources of water pollutants are: waste waters, seepings from open dumpings, mineral fertilizers and biocides washed out from agricultural areas, water pollutants emitted during storage and transport, air pollutants, and erosions from roads. The thermal load is an additional factor. Technical and legal steps are necessary in order to prevent water pollution and to maintain the quality of water required for its various uses. These measures are treated in detail. (orig./AK) [de

  9. Fatigue in Welded High-Strength Steel Plate Elements under Stochastic Loading

    DEFF Research Database (Denmark)

    Agerskov, Henning; Petersen, R.I.; Martinez, L. Lopez

    1999-01-01

    The present project is a part of an investigation on fatigue in offshore structures in high-strength steel. The fatigue life of plate elements with welded attachments is studied. The material used has a yield stress of ~ 810-840 MPa, and high weldability and toughness properties. Fatigue test...... series with constant amplitude loading and with various types of stochastic loading have been carried through on test specimens in high-strength steel, and - for a comparison - on test specimens in conventional offshore structural steel with a yield stress of ~ 400-410 MPa.A comparison between constant...... amplitude and variable amplitude fatigue test results shows shorter fatigue lives in variable amplitude loading than should be expected from the linear fatigue damage accumulation formula. Furthermore, in general longer fatigue lives were obtained for the test specimens in high-strength steel than those...

  10. Multifunctional Structures for High-Energy Lightweight Load-Bearing Storage

    Science.gov (United States)

    Loyselle, Patricia L.

    2018-01-01

    This is a pull-up banner of the Multifunctional Structures for High-Energy Lightweight Load-bearing Storage (M-SHELLS) technology that will be on display at the SciTech Conference in January 2018. Efforts in Multifunctional Structures for High Energy Load-Bearing Storage (M-Shells) are pushing the boundaries of development for hybrid electric propulsion for future commercial aeronautical transport. The M-Shells hybrid material would serve as the power/energy storage of the vehicle and provide structural integrity, freeing up usable volume and mass typically occupied by bulky batteries. The ultimate goal is to demonstrate a system-level mass savings with a multifunctional structure with energy storage.

  11. Nonlinear system identification of smart structures under high impact loads

    International Nuclear Information System (INIS)

    Sarp Arsava, Kemal; Kim, Yeesock; El-Korchi, Tahar; Park, Hyo Seon

    2013-01-01

    The main purpose of this paper is to develop numerical models for the prediction and analysis of the highly nonlinear behavior of integrated structure control systems subjected to high impact loading. A time-delayed adaptive neuro-fuzzy inference system (TANFIS) is proposed for modeling of the complex nonlinear behavior of smart structures equipped with magnetorheological (MR) dampers under high impact forces. Experimental studies are performed to generate sets of input and output data for training and validation of the TANFIS models. The high impact load and current signals are used as the input disturbance and control signals while the displacement and acceleration responses from the structure–MR damper system are used as the output signals. The benchmark adaptive neuro-fuzzy inference system (ANFIS) is used as a baseline. Comparisons of the trained TANFIS models with experimental results demonstrate that the TANFIS modeling framework is an effective way to capture nonlinear behavior of integrated structure–MR damper systems under high impact loading. In addition, the performance of the TANFIS model is much better than that of ANFIS in both the training and the validation processes. (paper)

  12. Nonlinear system identification of smart structures under high impact loads

    Science.gov (United States)

    Sarp Arsava, Kemal; Kim, Yeesock; El-Korchi, Tahar; Park, Hyo Seon

    2013-05-01

    The main purpose of this paper is to develop numerical models for the prediction and analysis of the highly nonlinear behavior of integrated structure control systems subjected to high impact loading. A time-delayed adaptive neuro-fuzzy inference system (TANFIS) is proposed for modeling of the complex nonlinear behavior of smart structures equipped with magnetorheological (MR) dampers under high impact forces. Experimental studies are performed to generate sets of input and output data for training and validation of the TANFIS models. The high impact load and current signals are used as the input disturbance and control signals while the displacement and acceleration responses from the structure-MR damper system are used as the output signals. The benchmark adaptive neuro-fuzzy inference system (ANFIS) is used as a baseline. Comparisons of the trained TANFIS models with experimental results demonstrate that the TANFIS modeling framework is an effective way to capture nonlinear behavior of integrated structure-MR damper systems under high impact loading. In addition, the performance of the TANFIS model is much better than that of ANFIS in both the training and the validation processes.

  13. Design of dynamic loading support on high temperature pipe

    International Nuclear Information System (INIS)

    Sitandung, Y.B.; Bandriyana, B.

    2002-01-01

    As a follow up to pipe stress analysis result caused by high temperature operation loading, a design of dynamic loading support was made. The type of variable and constant support as acceptable choosing are applicated for reduce of over stress and over load on piping system. Analysis line schedule of AP600 as an example with apply three dynamic loading support (two type variable and one type constant support). The pre-design of the third support above are based on analysis result with follow the support catalog and field condition wherein its supports are installed. To guarantee the performance and accurate of the support, checking is performed for spring working rate tolerance, support variability and swing angle. The design results of variable spring are loads, size, working rate, type tolerance, spring rate, variability, long and sway angle with each values 5000; 15; 1,25; VM; 0.655; 1080; 0.114; 114,5; 0,48 for S1 and 2045; 12; 0,583; VS; 0,237; 900; 0,132; 130; 0,34 for S3

  14. A novel monochromator for high heat-load synchrotron x-ray radiation

    International Nuclear Information System (INIS)

    Khounsary, A.M.

    1992-01-01

    The high heat load associated with the powerful and concentrated x-ray beams generated by the insertion devices at a number of present and many of the future (planned or under construction) synchrotron radiation facilities pose a formidable engineering challenge in the designer of the monochromators and other optical devices. For example, the Undulator A source on the Advanced Photon Source (APS) ring (being constructed at the Argonne National Laboratory) will generate as much as 10 kW of heat deposited on a small area (about 1 cm 2 ) of the first optics located some 24 m from the source. The peak normal incident heat flux can be as high as 500 W/mm 2 . Successful utilization of the intense x-ray beams from insertion devices critically depends on the development, design, and availability of optical elements that provide acceptable performance under high heat load. Present monochromators can handle, at best, heat load levels that are an order of magnitude lower than those generated by such sources. The monochromator described here and referred to as the open-quote inclinedclose quotes monochromator can provide a solution to high heat-load problems

  15. Stochastic clustering of material surface under high-heat plasma load

    Science.gov (United States)

    Budaev, Viacheslav P.

    2017-11-01

    The results of a study of a surface formed by high-temperature plasma loads on various materials such as tungsten, carbon and stainless steel are presented. High-temperature plasma irradiation leads to an inhomogeneous stochastic clustering of the surface with self-similar granularity - fractality on the scale from nanoscale to macroscales. Cauliflower-like structure of tungsten and carbon materials are formed under high heat plasma load in fusion devices. The statistical characteristics of hierarchical granularity and scale invariance are estimated. They differ qualitatively from the roughness of the ordinary Brownian surface, which is possibly due to the universal mechanisms of stochastic clustering of material surface under the influence of high-temperature plasma.

  16. Pollution, ecological-health risks, and sources of heavy metals in soil of the northeastern Qinghai-Tibet Plateau.

    Science.gov (United States)

    Wu, Jun; Lu, Jian; Li, Leiming; Min, Xiuyun; Luo, Yongming

    2018-06-01

    The Qinghai-Tibet Plateau, especially the northeastern region, is not a pure land any more due to recently increasing anthropogenic activities. This study collected soil samples from 70 sites of the northeastern Qinghai-Tibet Plateau to evaluate pollution, ecological-health risks, and possible pollution sources of heavy metals. The concentrations of heavy metals in soil were relatively high. Values of geo-accumulation index exhibited that Hg pollution was the most serious meanwhile Hg possessed the strongest enrichment feature based on enrichment factor values. The modified degrees of contamination showed that about 54.3% and 17.1% of sampling sites were at moderate and high contamination degree while pollution load indexes illustrated that 72.9% and 27.1% of sampling sites possessed moderate and high contamination level, respectively. Ecological risk indexes of heavy metals in soil ranged from 234.6 to 3759.0, suggesting that most of sites were under considerable/very high risks. Cancer risks for adults and children were determined as high and high-very high levels while non-cancer risks for children were high although those for adults were low. Industrial source contributed to the main fraction of ecological and health risks. Summarily speaking, heavy metals in soil of the study area has caused significantly serious pollution and exerted high potential ecological and health risks, especially for children who are more susceptible to hurt from pollutants. Therefore, more efficient and strict pollution control and management in study area should be put out as soon as possible. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. High-Frequency Axial Fatigue Test Procedures for Spectrum Loading

    Science.gov (United States)

    2016-07-20

    cycle runout limit. PURPOSE 2. To develop the capability to perform High-Frequency (H-F) Spectrum Fatigue tests, an in- house Basic and...response of the test specimen to the command input signal for load cycling . These cycle -by- cycle errors accumulate over the life of the test specimen...fatigue life model. It is expected that the cycle -by- cycle P-V error may vary substantially depending on the load spectrum content, the compensation

  18. Testing waste forms containing high radionuclide loadings

    International Nuclear Information System (INIS)

    McConnell, J.W. Jr.; Neilson, R.M. Jr.; Rogers, R.D.

    1986-01-01

    The Low-Level Waste Data Base Development - EPICOR-II Resin/Liner Investigation Program funded by the US Nuclear Regulatory Commission (NRC) is obtaining information on radioactive waste during NRC-prescribed tests and in a disposal environment. This paper describes the resin solidification task of that program, including the present status and results to date. An unusual aspect of this investigation is the use of commercial grade, ion exchange resins that have been loaded with over five times the radioactivity normally seen in a commercial application. That dramatically increases the total radiation dose to the resins. The objective of the resin solidification task is to determine the adequacy of test procedures specified by NRC for ion exchange resins having high radionuclide loadings

  19. Photoelectrically automated, bakeable, high-load ultramicrobalance

    International Nuclear Information System (INIS)

    Czanderna, A.W.; Kollen, W.; Biegen, J.R.; Rodder, J.

    1976-01-01

    An all quartz pivotal-beam ultramicrobalance has been modified for operation as a null instrument using a dual-path photoelectric detector. The beam and newly designed stainless steel beam support have been adapted to a stainless steel enclosure for studies in uhv. A thin quartz disk, with a 600-A thick Au film for partially blocking the light path, is fused to each end of the beam. An electronic circuit minimizes the signal from the detector when the balance moves from the null by providing a current output to a magnetic compensation coil. The capacity (up to 20 g), the stability of the null reading (over six months), and the unusually high load to precision ratio (1--2x10 8 ) of the balance have been maintained with the modification. Sensibilities of 0.03--0.1 μg with 4--10-g loads have been obtained with the balance, which is now completely adapted for UHV operation

  20. Landscape planning for agricultural nonpoint source pollution reduction III: Assessing phosphorus and sediment reduction potential

    Science.gov (United States)

    Diebel, M.W.; Maxted, J.T.; Robertson, Dale M.; Han, S.; Vander Zanden, M. J.

    2009-01-01

    Riparian buffers have the potential to improve stream water quality in agricultural landscapes. This potential may vary in response to landscape characteristics such as soils, topography, land use, and human activities, including legacies of historical land management. We built a predictive model to estimate the sediment and phosphorus load reduction that should be achievable following the implementation of riparian buffers; then we estimated load reduction potential for a set of 1598 watersheds (average 54 km2) in Wisconsin. Our results indicate that land cover is generally the most important driver of constituent loads in Wisconsin streams, but its influence varies among pollutants and according to the scale at which it is measured. Physiographic (drainage density) variation also influenced sediment and phosphorus loads. The effect of historical land use on present-day channel erosion and variation in soil texture are the most important sources of phosphorus and sediment that riparian buffers cannot attenuate. However, in most watersheds, a large proportion (approximately 70%) of these pollutants can be eliminated from streams with buffers. Cumulative frequency distributions of load reduction potential indicate that targeting pollution reduction in the highest 10% of Wisconsin watersheds would reduce total phosphorus and sediment loads in the entire state by approximately 20%. These results support our approach of geographically targeting nonpoint source pollution reduction at multiple scales, including the watershed scale. ?? 2008 Springer Science+Business Media, LLC.

  1. Environmental pollution: An enormous and invisible burden on health systems in low- and middle-income counties.

    Science.gov (United States)

    Landrigan, Philip J; Fuller, Richard

    2014-01-01

    Background. Environmental pollution has become the leading risk factor for death in low- and middle-income countries (LMICs). The World Health Organization and others calculate that exposures to polluted air - indoor and outdoor, water and soil resulted in 8.4 million deaths in LMICs in 2012. By comparison, HIV/AIDS causes 1.5 million deaths per year, and malaria and tuberculosis Less than 1 million each. The diseases caused by pollution include the traditional scourges of pneumonia and diarrhea, but increasingly they also include chronic, non-communicable diseases (NCDs) such as such as heart disease, stroke and cancer. Method. We review the diseases caused by pollution and the multiple economic and human burdens that these diseases impose on health systems in countries with already limited resources. Results. We find that diseases caused by pollution increase health care costs, especially for high-cost NCDs. They impose an unnecessary load on health care delivery systems by increasing hospital staffing needs and thus diverting resources from essential prevention programmes such as childhood immunizations, infection control and maternal and child health. They undermine the development of poor countries by reducing the health, intelligence and economic productivity of entire generations. Pollution is highly preventable and pollution prevention is highly cost-effective. Yet despite their high economic and human costs and amenability to prevention, the diseases caused by pollution have not received the attention that they deserve in policy planning or in the international development agenda. Conclusion. Pollution is not inevitable. It is a problem that can be solved in our lifetime. Given the great impact of pollution on health and health care resources and the high cost-benefit ratio of pollution prevention, efforts to mitigate pollution should become a key strategic priority for international funders and for governments of LMICs. Recommendation. Assisting LMICs to

  2. High level waste at Hanford: Potential for waste loading maximization

    International Nuclear Information System (INIS)

    Hrma, P.R.; Bailey, A.W.

    1995-09-01

    The loading of Hanford nuclear waste in borosilicate glass is limited by phase-related phenomena, such as crystallization or formation of immiscible liquids, and by breakdown of the glass structure because of an excessive concentration of modifiers. The phase-related phenomena cause both processing and product quality problems. The deterioration of product durability determines the ultimate waste loading limit if all processing problems are resolved. Concrete examples and mass-balance based calculations show that a substantial potential exists for increasing waste loading of high-level wastes that contain a large fraction of refractory components

  3. A Targeted "Capture" and "Removal" Scavenger toward Multiple Pollutants for Water Remediation based on Molecular Recognition.

    Science.gov (United States)

    Wang, Jie; Shen, Haijing; Hu, Xiaoxia; Li, Yan; Li, Zhihao; Xu, Jinfan; Song, Xiufeng; Zeng, Haibo; Yuan, Quan

    2016-03-01

    For the water remediation techniques based on adsorption, the long-standing contradictories between selectivity and multiple adsorbability, as well as between affinity and recyclability, have put it on weak defense amid more and more severe environment crisis. Here, a pollutant-targeting hydrogel scavenger is reported for water remediation with both high selectivity and multiple adsorbability for several pollutants, and with strong affinity and good recyclability through rationally integrating the advantages of multiple functional materials. In the scavenger, aptamers fold into binding pockets to accommodate the molecular structure of pollutants to afford perfect selectivity, and Janus nanoparticles with antibacterial function as well as anisotropic surfaces to immobilize multiple aptamers allow for simultaneously handling different kinds of pollutants. The scavenger exhibits high efficiencies in removing pollutants from water and it can be easily recycled for many times without significant loss of loading capacities. Moreover, the residual concentrations of each contaminant are well below the drinking water standards. Thermodynamic behavior of the adsorption process is investigated and the rate-controlling process is determined. Furthermore, a point of use device is constructed and it displays high efficiency in removing pollutants from environmental water. The scavenger exhibits great promise to be applied in the next generation of water purification systems.

  4. Status of the petroleum pollution in the Wider Caribbean Sea

    Energy Technology Data Exchange (ETDEWEB)

    Botello, Alfonso V; Villanueva F, Susana [Universidad Nacional Autonoma de Mexico, Mexico City (Mexico). Inst. de Ciencias del Mar y Limnologia

    1996-07-01

    In 1976, the IOC-UNESCO and UNEP convened a meeting in Port of Spain to analyze the marine pollution problems in the region and noted that petroleum pollution was of region-wide concern and recommended to initiate a research and monitoring program to determine the severity of the problem and monitor its effects. Actually, the Wider Caribbean is potentially one of the largest oil producing areas in the world. Major production sites include Louisiana and Texas; USA; the Bay of Campeche, Mexico; Lake Maracaibo, Venezuela; and the Gulf of Paria, Trinidad; all which are classified as production accident high-risk zones. Main sources of petroleum pollution in the Wider Caribbean are: production, exploitation, transportation, urban and municipal discharges, refining and chemical wastes, normal loading operations and accidental spills. About 5 million of barrels are transported daily in the Caribbean, thus generating an intense tanker traffic. It has been estimated that oil discharges from tank washings within the Wider Caribbean could be as high as 7 millions barrels/year. The results of the CARIPOL Regional Programme conducted between 1980-1987 pointed out that a significant levels of petroleum pollution exists throughout the Wider Caribbean and include serious tar contamination of windward exposed beaches, high levels of floating tar within the major currents system and very high levels of dissolved/dispersed hydrocarbons in surface waters. Major effects of this petroleum pollution include: high tar level on many beaches that either prevent recreational use or require very expensive clean-up operations, distress and death to marine life and responses in the enzyme systems of marine organisms that have been correlated with declines in reproductive success. Finally the presence of polycyclic aromatic hydrocarbons in tissues of important economic species have been reported with its potential carcinogenic effects. (author)

  5. Status of the petroleum pollution in the Wider Caribbean Sea

    International Nuclear Information System (INIS)

    Botello, Alfonso V.; Villanueva F, Susana

    1996-01-01

    In 1976, the IOC-UNESCO and UNEP convened a meeting in Port of Spain to analyze the marine pollution problems in the region and noted that petroleum pollution was of region-wide concern and recommended to initiate a research and monitoring program to determine the severity of the problem and monitor its effects. Actually, the Wider Caribbean is potentially one of the largest oil producing areas in the world. Major production sites include Louisiana and Texas; USA; the Bay of Campeche, Mexico; Lake Maracaibo, Venezuela; and the Gulf of Paria, Trinidad; all which are classified as production accident high-risk zones. Main sources of petroleum pollution in the Wider Caribbean are: production, exploitation, transportation, urban and municipal discharges, refining and chemical wastes, normal loading operations and accidental spills. About 5 million of barrels are transported daily in the Caribbean, thus generating an intense tanker traffic. It has been estimated that oil discharges from tank washings within the Wider Caribbean could be as high as 7 millions barrels/year. The results of the CARIPOL Regional Programme conducted between 1980-1987 pointed out that a significant levels of petroleum pollution exists throughout the Wider Caribbean and include serious tar contamination of windward exposed beaches, high levels of floating tar within the major currents system and very high levels of dissolved/dispersed hydrocarbons in surface waters. Major effects of this petroleum pollution include: high tar level on many beaches that either prevent recreational use or require very expensive clean-up operations, distress and death to marine life and responses in the enzyme systems of marine organisms that have been correlated with declines in reproductive success. Finally the presence of polycyclic aromatic hydrocarbons in tissues of important economic species have been reported with its potential carcinogenic effects. (author)

  6. The state of transboundary air pollution 1992 update. Report prepared within the framework of the Convention on Long-range Transboundary Air Pollution

    International Nuclear Information System (INIS)

    1993-01-01

    This ninth volume of the series of Air Pollution Studies, published under the auspices of the Executive Body for the Convention on Long-range Transboundary Air Pollution, contains documents reviewed and approved for publication at the tenth session of the Executive Body held at Geneva from 17 to 19 November 1992. Part One is the Annual Review of Strategies and Policies for Air Pollution Abatement. It is compiled on the basis of national data and reports received up to 31 December 1992. National emission data and forecasts for sulphur dioxide (SO 2 ), nitrogen oxides (NO x ), volatile organic compounds (VOCs), ammonia (NH 3 ), and carbon dioxide (CO 2 ) from 1980 to the year 2005 is presented. Part Two contains results of scenario analysis for sulphur abatement strategies. It is concluded, inter alia, that strategies can be found which, by differentiating emission reductions, provide greater environmental benefit than a uniform reduction at the same cost. It is also shown that a small number of high-emitting countries in Central Europe have significant impact on deposition of sulphur throughout Europe, and that emission reduction in these countries proves to be a cost-effective way of moving towards critical loads in Europe as a whole. Most of the scenarios analysed are based on reductions of current deposition in relation to critical loads, i.e., a decrease in the exceedances of critical loads. Part Three is an executive summary of the 1992 Report on Forest Condition in Europe, carried out under the International Cooperative Programme for Assessment and Monitoring of Air Pollution Effects on Forests. The full report has been jointly published by ECE and the Commission of the European Communities. It summarizes the results of surveys carried out in 1991 in 28 European countries and in several additional regions, conducted in accordance with common guidelines. Of 214 million hectares of forest in Europe (including major parts of the forests in the western part of the

  7. Estimation of pollution load from an industrial estate, south-western ...

    African Journals Online (AJOL)

    ETIM

    African Journal of Environmental Science and Technology Vol. 6(2), pp. 125-129 ... up pollution control strategies and prioritization of activities. ... effective intervention. The study .... natural eco-system of the Ota industrial estate. Industrial toxic ...

  8. Long-Term Hydrologic Impact Assessment of Non-point Source Pollution Measured Through Land Use/Land Cover (LULC) Changes in a Tropical Complex Catchment

    Science.gov (United States)

    Abdulkareem, Jabir Haruna; Sulaiman, Wan Nor Azmin; Pradhan, Biswajeet; Jamil, Nor Rohaizah

    2018-05-01

    The contribution of non-point source pollution (NPS) to the contamination of surface water is an issue of growing concern. Non-point source (NPS) pollutants are of various types and altered by several site-specific factors making them difficult to control due to complex uncertainties involve in their behavior. Kelantan River basin, Malaysia is a tropical catchment receiving heavy monsoon rainfall coupled with intense land use/land cover (LULC) changes making the area consistently flood prone thereby deteriorating the surface water quality in the area. This study was conducted to determine the spatio-temporal variation of NPS pollutant loads among different LULC changes and to establish a NPS pollutant loads relationships among LULC conditions and sub-basins in each catchment. Four pollutants parameters such as total suspended solids (TSS), total phosphorus (TP), total nitrogen (TN) and ammonia nitrogen (AN) were chosen with their corresponding event mean concentration values (EMC). Soil map and LULC change maps corresponding to 1984, 2002 and 2013 were used for the calculation of runoff and NPS pollutant loads using numeric integration in a GIS environment. Analysis of Variance (ANOVA) was conducted for the comparison of NPS pollutant loads among the three LULC conditions used and the sub-basins in each catchment. The results showed that the spatio-temporal variation of pollutant loads in almost all the catchments increased with changes in LULC condition as one moves from 1984 to 2013, with 2013 LULC condition found as the dominant in almost all cases. NPS pollutant loads among different LULC changes also increased with changes in LULC condition from 1984 to 2013. While urbanization was found to be the dominant LULC change with the highest pollutant load in all the catchments. Results from ANOVA reveals that statistically most significant ( p changes on NPS pollution. The findings of this study may be useful to water resource planners in controlling water pollution

  9. Spatially differentiated strategies for reducing nitrate loads from agriculture in two Danish catchments

    DEFF Research Database (Denmark)

    Hashemi, Fatemeh; Olesen, Jørgen Eivind; Hansen, Anne Lausten

    2018-01-01

    Nutrient loss from agriculture is the largest source of diffuse water pollution in Denmark. To reduce nutrient loads a number of solutions have been implemented, but this has been insufficient to achieve the environmental objectives without unacceptable repercussions for agricultural production...... reducing the source loading or enhancing the natural reduction (denitrification) of N after it is leached from the root zone of agricultural crops. In this study, a new method of spatially differentiated analysis for two Danish catchments (Odense and Norsminde) was conducted that reach across...... the individual farms to achieve selected N-load reduction targets. It includes application of cover crops within current crop rotations, set-a-side application on high N-load areas, and changes in agricultural management based on maps of N-reduction available for two different spatial scales, considering soil...

  10. High power s-band vacuum load

    Energy Technology Data Exchange (ETDEWEB)

    Neubauer, Michael [Muons, Inc., Batavia, IL (United States); Dudas, Alan [Muons, Inc., Batavia, IL (United States); Krasnykh, Anatoly [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2016-12-29

    Through a combination of experimentation and calculation the components of a novel room temperature dry load were successfully fabricated. These components included lossy ceramic cylinders of various lengths, thicknesses, and percent of silicon carbide (SiC). The cylinders were then assembled into stainless steel compression rings by differential heating of the parts and a special fixture. Post machining of this assembly provided a means for a final weld. The ring assemblies were then measured for S-parameters, individually and in pairs using a low-cost TE10 rectangular to TE01 circular waveguide adapter specially designed to be part of the final load assembly. Matched pairs of rings were measured for assembly into the final load, and a sliding short designed and fabricated to assist in determining the desired short location in the final assembly. The plan for the project was for Muons, Inc. to produce prototype loads for long-term testing at SLAC. The STTR funds for SLAC were to upgrade and operate their test station to ensure that the loads would satisfy their requirements. Phase III was to be the sale to SLAC of loads that Muons, Inc. would manufacture. However, an alternate solution that involved a rebuild of the old loads, reduced SLAC budget projections, and a relaxed time for the replacement of all loads meant that in-house labor will be used to do the upgrade without the need for the loads developed in this project. Consequently, the project was terminated before the long term testing was initiated. However, SLAC can use the upgraded test stand to compare the long-term performance of the ones produced in this project with their rebuilt loads when they are available.

  11. High power s-band vacuum load

    International Nuclear Information System (INIS)

    Neubauer, Michael; Dudas, Alan; Krasnykh, Anatoly

    2016-01-01

    Through a combination of experimentation and calculation the components of a novel room temperature dry load were successfully fabricated. These components included lossy ceramic cylinders of various lengths, thicknesses, and percent of silicon carbide (SiC). The cylinders were then assembled into stainless steel compression rings by differential heating of the parts and a special fixture. Post machining of this assembly provided a means for a final weld. The ring assemblies were then measured for S-parameters, individually and in pairs using a low-cost TE10 rectangular to TE01 circular waveguide adapter specially designed to be part of the final load assembly. Matched pairs of rings were measured for assembly into the final load, and a sliding short designed and fabricated to assist in determining the desired short location in the final assembly. The plan for the project was for Muons, Inc. to produce prototype loads for long-term testing at SLAC. The STTR funds for SLAC were to upgrade and operate their test station to ensure that the loads would satisfy their requirements. Phase III was to be the sale to SLAC of loads that Muons, Inc. would manufacture. However, an alternate solution that involved a rebuild of the old loads, reduced SLAC budget projections, and a relaxed time for the replacement of all loads meant that in-house labor will be used to do the upgrade without the need for the loads developed in this project. Consequently, the project was terminated before the long term testing was initiated. However, SLAC can use the upgraded test stand to compare the long-term performance of the ones produced in this project with their rebuilt loads when they are available.

  12. Behaviour of arsenic in forested catchments following a high-pollution period

    International Nuclear Information System (INIS)

    Novak, Martin; Erbanova, Lucie; Fottova, Daniela; Cudlin, Pavel; Kubena, Ales

    2011-01-01

    Due to high availability of adsorption sites, forested catchments could be net sinks for pollutant arsenic both during the period of increasing and decreasing pollution. We tested this hypothesis along a north-south pollution gradient in spruce die-back affected areas of Central Europe. For two water years (2007-2008), we monitored As fluxes via spruce-canopy throughfall, open-area precipitation, and runoff in four headwater catchments (Czech Republic). Since 1980, atmospheric As inputs decreased 26 times in the north, and 13 times in the south. Arsenic export by runoff was similar to atmospheric inputs at three sites, resulting in a near-zero As mass balance. One site exhibited a net export of As (2.2 g ha -1 yr -1 ). In contrast, the preceding period (1995-2006) showed much higher As fluxes, and higher As export. Czech catchments do not serve as net sinks of atmospheric As. A considerable proportion of old industrial arsenic is flushed out of the soil. - Following a period of high atmospheric As deposition, a considerable proportion of old industrial arsenic is flushed out of soil and exported from forested catchments.

  13. Black carbon concentrations in the highly polluted Kathmandu Valley, Nepal: a three year monitoring with a dual-spot Aethalometer

    Science.gov (United States)

    Rupakheti, Maheswar; Drinovec, Luka; Puppala, SivaPraveen; Mahata, Khadak; Rupakheti, Dipesh; Kathayat, Bhogendra; Singdan, Pratik; Panday, Arnico; Lawrence, Mark

    2016-04-01

    Our knowledge about ambient black carbon (BC) in the vast Himalayan region, a region vulnerable to impacts of global warming, is very limited due to unavailability of a long-term ambient monitoring. Here we present results from a continuous monitoring of ambient BC concentrations, with a new generation Aethalometer (AE33), over a three year period (January 2013- January 2016) at a semi-urban site in the highly polluted Kathmandu Valley in the foothills of the central Himalaya, one of the most polluted cities in the world. This is the longest time series of BC concentrations that have been monitored with AE33 (which uses the dual-spot technique for a real-time filter loading compensation) in highly polluted ambient environment. The measurements were carried out under the framework of project SusKat (Sustainable Atmosphere for the Kathmandu Valley). BC concentrations were found to be extremely high, especially in winter and the pre-monsoon period, with the hourly-averaged values often exceeding 50 μg/m3. BC concentrations showed a clear diurnal cycle with a prominent peak around 8-9 am and a second peak around 8-9 pm local time in all four seasons. Night-time BC was also fairly high. The diurnal cycle was driven by a combination of increased emissions from traffic, cooking activities, garbage burning, and lower mixing heights (˜200 m) and reduced horizontal ventilation in the mornings and evenings. BC concentrations showed significant seasonal variations - a maximum in winter season and minimum during the monsoon (rainy) season, with monthly average values in the range 5-30 μg/m3. An increase in emissions from the operation of over 100 brick kilns in winter and spring, and an increase in the use of small but numerous diesel power generators during hours with power cuts contributed significantly to ambient BC concentrations in the valley. Fractional contributions of biomass burning and fossil fuel combustion to BC was estimated based on a real-time method for

  14. The protection of urban areas from surface wastewater pollutions

    Directory of Open Access Journals (Sweden)

    Vialkova Elena

    2017-01-01

    Full Text Available In this paper it considered the problem of collection, treatment and discharge into waters of rain and melted wastewater. To reduce the load on the combined sewer system, there are engineering solutions collect rain and melt water for use in the irrigation of lawns and green spaces. Research carried out at the department “Water supply and sanitation”, (Russia, confirm the high pollution concentrations of meltwater and rainfall in urban arias. Series of measurements of heavy metal in rainwater runoff carried out in Hungary demonstrates clearly the differences in concentrations in the function of distance from the edge of the road. Also differences are introduced between pollution concentrations in runoff water from within and outside urban traffic roads. The quality of snow cover, forming meltwater is observed to be changing in dependence on roadway location. Quality characteristics of surface runoff and its sediments can be effectively improved with super-high frequency radiation (SHF treatment which is presented in this paper.

  15. Metabolic impacts of high dietary exposure to persistent organic pollutants in mice

    DEFF Research Database (Denmark)

    Ibrahim, Mohammad Madani; Fjære, Even; Lock, Erik-Jan

    2012-01-01

    Persistent organic pollutants (POPs) have been linked to metabolic diseases. Yet, the effects of high exposure to dietary POPs remain unclear. We therefore investigated whether elevated exposure to POPs provided by whale meat supplementation could contribute to insulin resistance. C57BL/6J mice...... were fed control (C) or very high-fat diet (VHF) containing low or high levels of POPs (VHF+POPs) for eight weeks. To elevate the dietary concentrations of POPs, casein was replaced by whale meat containing high levels of pollutants. Feeding VHF+POPs induced high POP accumulation in the adipose tissue...... of mice. However, compared with VHF-fed mice, animals fed VHF+POPs had improved insulin sensitivity and glucose tolerance, and reduced body weight. Levels of ectopic fat in skeletal muscles and liver were reduced in mice fed VHF+POPs. These mice also gained less adipose tissue and had a tendency...

  16. Review of 20 years research in fatigue of high pressure loaded components

    Energy Technology Data Exchange (ETDEWEB)

    Thumser, Rayk [Bauhaus Univ. Weimar (Germany). Materialforschungs- und -pruefanstalt; Scheibe, Wolfgang

    2011-07-01

    This paper gives an overview of the research in fatigue of high pressure loaded components. In the last 20 years the main research was carried out in Germany. This research was mainly driven by the fatigue requirements for high pressure loaded Diesel engine injection parts as common rails, injectors and pipes. (orig.)

  17. Estimating ammonium and nitrate load from septic systems to surface water bodies within ArcGIS environments

    Science.gov (United States)

    Zhu, Yan; Ye, Ming; Roeder, Eberhard; Hicks, Richard W.; Shi, Liangsheng; Yang, Jinzhong

    2016-01-01

    This paper presents a recently developed software, ArcGIS-based Nitrogen Load Estimation Toolkit (ArcNLET), for estimating nitrogen loading from septic systems to surface water bodies. The load estimation is important for managing nitrogen pollution, a world-wide challenge to water resources and environmental management. ArcNLET simulates coupled transport of ammonium and nitrate in both vadose zone and groundwater. This is a unique feature that cannot be found in other ArcGIS-based software for nitrogen modeling. ArcNLET is designed to be flexible for the following four simulating scenarios: (1) nitrate transport alone in groundwater; (2) ammonium and nitrate transport in groundwater; (3) ammonium and nitrate transport in vadose zone; and (4) ammonium and nitrate transport in both vadose zone and groundwater. With this flexibility, ArcNLET can be used as an efficient screening tool in a wide range of management projects related to nitrogen pollution. From the modeling perspective, this paper shows that in areas with high water table (e.g. river and lake shores), it may not be correct to assume a completed nitrification process that converts all ammonium to nitrate in the vadose zone, because observation data can indicate that substantial amount of ammonium enters groundwater. Therefore, in areas with high water table, simulating ammonium transport and estimating ammonium loading, in addition to nitrate transport and loading, are important for avoiding underestimation of nitrogen loading. This is demonstrated in the Eggleston Heights neighborhood in the City of Jacksonville, FL, USA, where monitoring well observations included a well with predominant ammonium concentrations. The ammonium loading given by the calibrated ArcNLET model can be 10-18% of the total nitrogen load, depending on various factors discussed in the paper.

  18. Diffuse pollution by persistent organic pollutants as measured in plastic pellets sampled from various beaches in Greece.

    Science.gov (United States)

    Karapanagioti, H K; Endo, S; Ogata, Y; Takada, H

    2011-02-01

    Plastic pellets found stranded on beaches are hydrophobic organic materials and thus, they are a favourable medium for persistent organic pollutants to absorb to. In the present study, plastic pellets are used to determine the diffuse pollution of selected Greek beaches. Samples of pellets were taken from these beaches and were analyzed for PCBs, DDTs, HCHs, and PAHs. The observed differences among pellets from various sampling sites are related to the pollution occurring at each site. Plastic pellets collected in Saronikos Gulf beaches demonstrate much higher pollutant loading than the ones collected in a remote island or close to an agricultural area. Based on data collected in this study and the International Pellet Watch program, pollution in Saronikos Gulf, Greece, is comparable to other heavily industrialized places of the world. The present study demonstrates the potential of pellet watch to be utilized as a detailed-scale monitoring tool within a single country. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. [Pollution load and the first flush effect of phosphorus in urban runoff of Wenzhou City].

    Science.gov (United States)

    Zhou, Dong; Chen, Zhen-lou; Bi, Chun-juan

    2012-08-01

    Five typical rainfalls were monitored in two different research areas of Wenzhou municipality. The pH and concentrations of total phosphorus (TP), dissolved phosphorus (DP), particulate phosphorus (PP), total inorganic carbon (TIC), total organic carbon (TOC), total suspended substances (TSS), BOD5 and COD in six different kinds of urban runoff were measured. The results showed that, the concentrations of TP, DP and PP in different kinds of urban runoff of Wenzhou ranged from 0.01 to 4.32 mg x L(-1), ND to 0.88 mg x L(-1) and ND to 4.31 mg x L(-1), respectively. In the early stages of runoff process PP was dominated, while in the later, the proportion of DP in most of the runoff samples would show a rising trend, especially in roof and outlet runoff. Judged by the event mean concentration (EMC) of TP and DP in these five rainfalls, some kinds of urban runoff could cause environmental pressure to the next level receiving water bodies. Meanwhile, the differences among the TP and DP content (maximum, minimum and mean content) in various urban runoffs were significant, and so were the differences among various rainfall events. According to the M (V) curve, the first flush effect of TP in most kinds of urban runoff was common; while the first flush effect of DP was more difficult to occur comparing with TP. Not only the underlying surface types but also many physico-chemical properties of runoff could affect the concentration of TP in urban runoff. All the results also suggested that different best management plans (BMPs) should be selected for various urban runoff types for the treatment of phosphorus pollution, and reducing the concentration of TSS is considered as one of the effective ways to decrease the pollution load of phosphorus in urban runoff.

  20. Linking the environmental loads to the fate of PPCPs in Beijing: Considering both the treated and untreated wastewater sources

    International Nuclear Information System (INIS)

    Wang, Bin; Dai, Guohua; Deng, Shubo; Huang, Jun; Wang, Yujue; Yu, Gang

    2015-01-01

    The environmental loads of pharmaceutical and personal care products (PPCPs) in Beijing were estimated from direct discharge of untreated wastewater and WWTP treated effluent. The annual environmental loads of 15 PPCP components ranged from 16.3 kg (propranolol) to 9.85 tons (caffeine). A fugacity model was developed to successfully estimate the PPCP pollution based on the estimated environmental load. The modeled results approximated the observed PPCP concentrations in Beijing. The untreated wastewater contributed significantly to PPCP pollution in Beijing, ranging from 46% (propranolol) to 99% (caffeine). The total environmental burden of target PPCPs ranged from 0.90 kg (propranolol) to 536 kg (caffeine). Water is the most important media for the fate of PPCPs. Monte Carlo-based concentration distributions of PPCPs are consistent with the observed results. The most important way to reduce the PPCP pollution is to both improve wastewater collection rate and adopt deep treatment technologies. - Highlights: • Annual environmental loads of PPCPs ranged from 16.3 kg to 9.85 tons in Beijing. • The environmental loads can be linked to PPCP pollution by fugacity model. • Untreated wastewater significantly contributed to PPCP pollution in Beijing. • The environmental burden of 15 PPCPs in Beijing ranged from 0.90 kg to 536 kg. • Uncertainty simulation successfully generated PPCP concentration distribution. - The environmental loads from both the treated and untreated wastewater sources contribute to PPCPs pollution in the surface water in Beijing, China

  1. A Nacre-Like Carbon Nanotube Sheet for High Performance Li-Polysulfide Batteries with High Sulfur Loading.

    Science.gov (United States)

    Pan, Zheng-Ze; Lv, Wei; He, Yan-Bing; Zhao, Yan; Zhou, Guangmin; Dong, Liubing; Niu, Shuzhang; Zhang, Chen; Lyu, Ruiyang; Wang, Cong; Shi, Huifa; Zhang, Wenjie; Kang, Feiyu; Nishihara, Hirotomo; Yang, Quan-Hong

    2018-06-01

    Lithium-sulfur (Li-S) batteries are considered as one of the most promising energy storage systems for next-generation electric vehicles because of their high-energy density. However, the poor cyclic stability, especially at a high sulfur loading, is the major obstacles retarding their practical use. Inspired by the nacre structure of an abalone, a similar configuration consisting of layered carbon nanotube (CNT) matrix and compactly embedded sulfur is designed as the cathode for Li-S batteries, which are realized by a well-designed unidirectional freeze-drying approach. The compact and lamellar configuration with closely contacted neighboring CNT layers and the strong interaction between the highly conductive network and polysulfides have realized a high sulfur loading with significantly restrained polysulfide shuttling, resulting in a superior cyclic stability and an excellent rate performance for the produced Li-S batteries. Typically, with a sulfur loading of 5 mg cm -2 , the assembled batteries demonstrate discharge capacities of 1236 mAh g -1 at 0.1 C, 498 mAh g -1 at 2 C and moreover, when the sulfur loading is further increased to 10 mg cm -2 coupling with a carbon-coated separator, a superhigh areal capacity of 11.0 mAh cm -2 is achieved.

  2. Pinus roxburghii plant needles as a three-season biomonitor for elemental air pollution monitoring along roadside

    Energy Technology Data Exchange (ETDEWEB)

    Daud, Muhammad; Wasim, Mohammad; Khalid, Nasir; Waheed, Shahida [Pakistan Institute of Nuclear Science and Technology, Islamabad (Pakistan). Chemistry Div.

    2015-07-01

    The present study deals with the determination of 36 elements in Pinus roxburghii plant needles to assess their potential as biomonitor for elemental air pollution monitoring. The elemental quantification was made by employing Instrumental Neutron Activation Analysis (INAA) and Atomic Absorption Spectrometric (AAS) techniques. The needles of Pinus roxburghii were collected in spring, summer and winter seasons from various sites in Islamabad. The method validation was performed by analyzing two certified reference materials i.e., Citrus leaves - NIST-SRM-1572 and IAEA-Soil-7. Pollution level was assessed by using three indicators: enrichment factor, pollution load index and average toxic element concentration. The results indicated that the needles of Pinus roxburghii plant had potential to monitor the extent of air pollution in the vicinity of high traffic areas.

  3. Controlled nanostructure and high loading of single-walled carbon nanotubes reinforced polycarbonate composite

    International Nuclear Information System (INIS)

    Wang Shiren; Liang Zhiyong; Pham, Giang; Park, Young-Bin; Wang, Ben; Zhang, Chuck; Kramer, Leslie; Funchess, Percy

    2007-01-01

    This paper presents an effective technique to fabricate thermoplastic nanocomposites with high loading of well-dispersed single-walled carbon nanotubes (SWNTs). SWNT membranes were made from a multi-step dispersion and filtration method, and then impregnated with polycarbonate solution to make thermoplastic nanocomposites. High loading of nanotubes was achieved by controlling the viscosity of polycarbonate solution. SEM and AFM characterization results revealed the controlled nanostructure in the resultant nanocomposites. Dynamic mechanical property tests indicated that the storage modulus of the resulting nanocomposites at 20 wt% nanotubes loading was improved by a factor of 3.4 compared with neat polycarbonate material. These results suggest the developed approach is an effective way to fabricate thermoplastic nanocomposites with good dispersion and high SWNT loading

  4. A national assessment of the effect of intensive agro-land use practices on nonpoint source pollution using emission scenarios and geo-spatial data.

    Science.gov (United States)

    Zhuo, Dong; Liu, Liming; Yu, Huirong; Yuan, Chengcheng

    2018-01-01

    China's intensive agriculture has led to a broad range of adverse impacts upon ecosystems and thereby caused environmental quality degradation. One of the fundamental problems that face land managers when dealing with agricultural nonpoint source (NPS) pollution is to quantitatively assess the NPS pollution loads from different sources at a national scale. In this study, export scenarios and geo-spatial data were used to calculate the agricultural NPS pollution loads of nutrient, pesticide, plastic film residue, and crop straw burning in China. The results provided the comprehensive and baseline knowledge of agricultural NPS pollution from China's arable farming system in 2014. First, the nitrogen (N) and phosphorus (P) emission loads to water environment were estimated to be 1.44 Tg N and 0.06 Tg P, respectively. East and south China showed the highest load intensities of nutrient release to aquatic system. Second, the amount of pesticide loss to water of seven pesticides that are widely used in China was estimated to be 30.04 tons (active ingredient (ai)). Acetochlor was the major source of pesticide loss to water, contributing 77.65% to the total loss. The environmental impacts of pesticide usage in east and south China were higher than other parts. Third, 19.75% of the plastic film application resided in arable soils. It contributed a lot to soil phthalate ester (PAE) contamination. Fourth, 14.11% of straw produce were burnt in situ, most occurring in May to July (post-winter wheat harvest) in North China Plain and October to November (post-rice harvest days) in southeast China. All the above agricultural NPS pollution loadings were unevenly distributed across China. The spatial correlations between pollution loads at land unit scale were also estimated. Rising labor cost in rural China might be a possible explanation for the general positive correlations of the NPS pollution loads. It also indicated a co-occurred higher NPS pollution loads and a higher

  5. Can the watershed non-point phosphorus pollution be interpreted by critical soil properties? A new insight of different soil P states.

    Science.gov (United States)

    Lin, Chen; Ma, Ronghua; Xiong, Junfeng

    2018-07-01

    The physicochemical properties of surface soil play a key role in the fate of watershed non-point source pollution. Special emphasis is needed to identify soil properties that are sensitive to both particulate P (PP) pollution and dissolved P (DP) pollution, which is essential for watershed environmental management. The Chaohu Lake basin, a typical eutrophic lake in China, was selected as the study site. The spatial features of the Non-point Source (NPS) PP loads and DP loads were calculated simultaneously based on the integration of sediment delivery distributed model (SEDD) and pollution loads (PLOAD) model. Then several critical physicochemical soil properties, especially various soil P compositions, were innovatively introduced to determine the response of the critical soil properties to NPS P pollution. The findings can be summarized: i) the mean PP load value of the different sub-basins was 5.87 kg, and PP pollution is regarded to be the primary NPS P pollution state, while the DP loads increased rapidly under the rapid urbanization process. ii) iron-bound phosphorus (Fe-P) and aluminum-bound phosphorus (Al-P) are the main components of available P and showed the most sensitive responses to NPS PP pollution, and the correlation coefficients were approximately 0.9. Otherwise, the residual phosphorus (Res-P) was selected as a sensitive soil P state that was significantly negatively correlated with the DP loads. iii) The DP and PP concentrations were represented differently when they were correlated with various soil properties, and the clay proportion was strongly negatively related to the PP loads. Meanwhile, there is a non-linear relationship between the DP loads and the critical soil properties, such as Fe and Total Nitrogen (TN) concentrations. Specifically, a strong inhibitory effect of TN concentration on the DP load was apparent in the Nanfei river (NF) and Paihe (PH) river basins where the R 2 reached 0.67, which contrasts with the relatively poor

  6. Structural response of full-scale concrete bridges subjected to high load magnitudes

    DEFF Research Database (Denmark)

    Halding, Philip Skov; Schmidt, Jacob Wittrup; Jensen, Thomas Westergaard

    -shaped concrete elements. The test method is outlined in the paper, which includes a description of a novel test-rig used to apply a high magnitude loading. It was shown that the test rig could perform controlled testing in only one day, which is an important aspect, since available time (due to traffic...... disturbance) often is an issue when testing on site. Also, different types of measuring equipment such as lasers, LVDT’s and DIC-cameras was investigated, in order to evaluate the deformations during loading of one of the OT-beam bridges. The monitoring equipment was studied to verify if such equipment...... efficiently could be used for in-situ measurements. The load was applied semi-deformation controlled by a combination of dead load and hydraulic jacks. The novel high magnitude loading-rig worked well. It was also possible to achieve good readings from the monitoring equipment in combination with the applied...

  7. Impact of high soot-loaded and regenerated diesel particulate filters on the emissions of persistent organic pollutants from a diesel engine fueled with waste cooking oil-based biodiesel

    International Nuclear Information System (INIS)

    Chen, Chia-Yang; Lee, Wen-Jhy; Wang, Lin-Chi; Chang, Yu-Cheng; Yang, Hsi-Hsien; Young, Li-Hao; Lu, Jau-Huai; Tsai, Ying I.; Cheng, Man-Ting; Mwangi, John Kennedy

    2017-01-01

    Highlights: • WCO-based biodiesel blends cannot stimulate POPs formation in uncatalyzed DPF. • Formation mechanism of POPs in diesel engines is homogeneous gas-phase formation. • The gas-phase POPs are highly dominant in the raw exhausts of diesel engines. • The regeneration of the DPF can drastically reduce the formation potential of POPs in the DPFs. - Abstract: This study evaluated the impact on persistent organic pollutant (POP) emissions from a diesel engine when deploying a diesel oxidation catalyst (DOC) combined with an uncatalyzed diesel particulate filter (DPF), as well as fueling with conventional diesel (B2) and waste cooking oil-based (WCO-based) biodiesel blends (B10 and B20). When the engine was fueled with WCO-based biodiesel blends (B10 and B20) in combination with deploying DOC+A-DPF, their levels of the chlorine and potassium contents could not stimulate the formation of chlorinated POPs (PCDD/Fs and PCBs), although previous studies had warned that happened on diesel engines fueled with biodiesel and deployed with iron-catalyzed DPFs. In contrast, the WCO-based biodiesel with a lower aromatic content reduced the precursors for POP formation, and its higher oxygen content compared to diesel promoted more complete combustion, and thus using WCO-based biodiesel could reduce both PM_2_._5 and POP emissions from diesel engines. This study also evaluated the impact of DPF conditions on the POP emissions from a diesel engine; that is, the difference in POP emissions before and just after the regeneration of the DPF. In comparison to the high soot-loaded DPF scenario, the regeneration of the DPF can drastically reduce the formation potential of POPs in the DPFs. An approach was developed to correct the effects of sampling artifacts on the partitioning of gas- and particle-phase POPs in the exhaust. The gas-phase POPs are highly dominant (89.7–100%) in the raw exhausts of diesel engines, indicating that the formation mechanism of POPs in diesel

  8. Integrated Watershed Pollution Control at Wujingang Canal, China

    Science.gov (United States)

    Zheng, Z.; Yang, X.; Luo, X.

    2012-04-01

    With a drainage area of 400 square kilometers, Wujingang Canal is located at the economically developed Yangtz Delta of eastern China. As a major tributary, the canal contributes a significant amount of pollutant load to the Lake Tai. Over the past many years, water quality of the canal and its tributaries could not meet the lowest Category V of Chinese surface water quality standard, indicating that its water is not suitable for the purposes of irrigation or scenic views. Major pollution sources in the watershed include industries, residential households, agriculture, fishery, and animal feedlot operations. A comprehensive plan with a budget of 2 billion RMB for the Wujingang watershed pollution control was developed in 2008 and has been implemented progressively ever since. Major components of the plan include: (1) advanced treatment of wastewater from industries and municipal sewage plants for further removal of nitrogen and phosphorous; (2) industrial wastewater reuse; (3) contiguous treatment of sewage from rural residential households with cost-effective technologies such as tower ecofilter system; (4) recycling of rural wastes to generate high-value added products using technologies such as multi-phase anaerobic co-digestion; and (5) making full use of the local landscape and configuring physical, chemical, and biological pollutant treatment structures to build the "clean river network" for treatment of mildly polluted agricultural discharge and surface runoff. Through the implementation of the above measures, water quality of the Wujingang Canal and its tributaries is expected to improve to meet Category IV of Chinese surface water quality standard by 2012, and Category III standard by 2020. Keywords watershed pollution control, non-point source pollution, rural sewage, rural waste, Lake Tai

  9. Brittle materials at high-loading rates: an open area of research

    Science.gov (United States)

    2017-01-01

    Brittle materials are extensively used in many civil and military applications involving high-strain-rate loadings such as: blasting or percussive drilling of rocks, ballistic impact against ceramic armour or transparent windshields, plastic explosives used to damage or destroy concrete structures, soft or hard impacts against concrete structures and so on. With all of these applications, brittle materials are subjected to intense loadings characterized by medium to extremely high strain rates (few tens to several tens of thousands per second) leading to extreme and/or specific damage modes such as multiple fragmentation, dynamic cracking, pore collapse, shearing, mode II fracturing and/or microplasticity mechanisms in the material. Additionally, brittle materials exhibit complex features such as a strong strain-rate sensitivity and confining pressure sensitivity that justify expending greater research efforts to understand these complex features. Currently, the most popular dynamic testing techniques used for this are based on the use of split Hopkinson pressure bar methodologies and/or plate-impact testing methods. However, these methods do have some critical limitations and drawbacks when used to investigate the behaviour of brittle materials at high loading rates. The present theme issue of Philosophical Transactions A provides an overview of the latest experimental methods and numerical tools that are currently being developed to investigate the behaviour of brittle materials at high loading rates. This article is part of the themed issue ‘Experimental testing and modelling of brittle materials at high strain rates’. PMID:27956517

  10. Brittle materials at high-loading rates: an open area of research

    Science.gov (United States)

    Forquin, Pascal

    2017-01-01

    Brittle materials are extensively used in many civil and military applications involving high-strain-rate loadings such as: blasting or percussive drilling of rocks, ballistic impact against ceramic armour or transparent windshields, plastic explosives used to damage or destroy concrete structures, soft or hard impacts against concrete structures and so on. With all of these applications, brittle materials are subjected to intense loadings characterized by medium to extremely high strain rates (few tens to several tens of thousands per second) leading to extreme and/or specific damage modes such as multiple fragmentation, dynamic cracking, pore collapse, shearing, mode II fracturing and/or microplasticity mechanisms in the material. Additionally, brittle materials exhibit complex features such as a strong strain-rate sensitivity and confining pressure sensitivity that justify expending greater research efforts to understand these complex features. Currently, the most popular dynamic testing techniques used for this are based on the use of split Hopkinson pressure bar methodologies and/or plate-impact testing methods. However, these methods do have some critical limitations and drawbacks when used to investigate the behaviour of brittle materials at high loading rates. The present theme issue of Philosophical Transactions A provides an overview of the latest experimental methods and numerical tools that are currently being developed to investigate the behaviour of brittle materials at high loading rates. This article is part of the themed issue 'Experimental testing and modelling of brittle materials at high strain rates'.

  11. Pollutant Transport and Fate: Relations Between Flow-paths and Downstream Impacts of Human Activities

    Science.gov (United States)

    Thorslund, J.; Jarsjo, J.; Destouni, G.

    2017-12-01

    The quality of freshwater resources is increasingly impacted by human activities. Humans also extensively change the structure of landscapes, which may alter natural hydrological processes. To manage and maintain freshwater of good water quality, it is critical to understand how pollutants are released into, transported and transformed within the hydrological system. Some key scientific questions include: What are net downstream impacts of pollutants across different hydroclimatic and human disturbance conditions, and on different scales? What are the functions within and between components of the landscape, such as wetlands, on mitigating pollutant load delivery to downstream recipients? We explore these questions by synthesizing results from several relevant case study examples of intensely human-impacted hydrological systems. These case study sites have been specifically evaluated in terms of net impact of human activities on pollutant input to the aquatic system, as well as flow-path distributions trough wetlands as a potential ecosystem service of pollutant mitigation. Results shows that although individual wetlands have high retention capacity, efficient net retention effects were not always achieved at a larger landscape scale. Evidence suggests that the function of wetlands as mitigation solutions to pollutant loads is largely controlled by large-scale parallel and circular flow-paths, through which multiple wetlands are interconnected in the landscape. To achieve net mitigation effects at large scale, a large fraction of the polluted large-scale flows must be transported through multiple connected wetlands. Although such large-scale flow interactions are critical for assessing water pollution spreading and fate through the landscape, our synthesis shows a frequent lack of knowledge at such scales. We suggest ways forward for addressing the mismatch between the large scales at which key pollutant pressures and water quality changes take place and the

  12. Workshop on high heat load x-ray optics

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    A workshop on High Heat Load X-Ray Optics'' was held at Argonne National Laboratory on August 3--5, 1989. The object of this workshop was to discuss recent advances in the art of cooling x-ray optics subject to high heat loads from synchrotron beams. The cooling of the first optical element in the intense photon beams that will be produced in the next generation of synchrotron sources is recognized as one of the major challenges that must be faced before one will be able to use these very intense beams in future synchrotron experiments. Considerable advances have been made in this art during the last few years, but much work remains to be done before the heating problem can be said to be completely solved. Special emphasis was placed on recent cooling experiments and detailed finite element'' and finite difference'' calculations comparing experiment with theory and extending theory to optimize performance.

  13. Workshop on high heat load x-ray optics

    International Nuclear Information System (INIS)

    1990-01-01

    A workshop on ''High Heat Load X-Ray Optics'' was held at Argonne National Laboratory on August 3--5, 1989. The object of this workshop was to discuss recent advances in the art of cooling x-ray optics subject to high heat loads from synchrotron beams. The cooling of the first optical element in the intense photon beams that will be produced in the next generation of synchrotron sources is recognized as one of the major challenges that must be faced before one will be able to use these very intense beams in future synchrotron experiments. Considerable advances have been made in this art during the last few years, but much work remains to be done before the heating problem can be said to be completely solved. Special emphasis was placed on recent cooling experiments and detailed ''finite element'' and ''finite difference'' calculations comparing experiment with theory and extending theory to optimize performance

  14. Tropospheric Emissions: Monitoring of Pollution (TEMPO)

    Science.gov (United States)

    Zoogman, P.; Liu, X.; Suleiman, R. M.; Pennington, W. F.; Flittner, D. E.; Al-Saadi, J. A.; Hilton, B. B.; Nicks, D. K.; Newchurch, M. J.; Carr, J. L.; hide

    2016-01-01

    TEMPO (Tropospheric Emissions: Monitoring of Pollution) was selected in 2012 by NASA as the first Earth Venture Instrument, for launch between 2018 and 2021. It will measure atmospheric pollution for greater North America from space using ultraviolet and visible spectroscopy. TEMPO observes from Mexico City, Cuba, and the Bahamas to the Canadian oil sands, and from the Atlantic to the Pacific, hourly and at high spatial resolution (approximately 2.1 kilometers N/S by 4.4 kilometers E/W at 36.5 degrees N, 100 degrees W). TEMPO provides a tropospheric measurement suite that includes the key elements of tropospheric air pollution chemistry, as well as contributing to carbon cycle knowledge. Measurements are made hourly from geostationary (GEO) orbit, to capture the high variability present in the diurnal cycle of emissions and chemistry that are unobservable from current low-Earth orbit (LEO) satellites that measure once per day. The small product spatial footprint resolves pollution sources at sub-urban scale. Together, this temporal and spatial resolution improves emission inventories, monitors population exposure, and enables effective emission-control strategies. TEMPO takes advantage of a commercial GEO host spacecraft to provide a modest cost mission that measures the spectra required to retrieve ozone (O3), nitrogen dioxide (NO2), sulfur dioxide (SO2), formaldehyde (H2CO), glyoxal (C2H2O2), bromine monoxide (BrO), IO (iodine monoxide),water vapor, aerosols, cloud parameters, ultraviolet radiation, and foliage properties. TEMPO thus measures the major elements, directly or by proxy, in the tropospheric O3 chemistry cycle. Multi-spectral observations provide sensitivity to O3 in the lowermost troposphere, substantially reducing uncertainty in air quality predictions. TEMPO quantifies and tracks the evolution of aerosol loading. It provides these near-real-time air quality products that will be made publicly available. TEMPO will launch at a prime time to be the

  15. Noise, air pollutants and traffic: continuous measurement and correlation at a high-traffic location in New York City.

    Science.gov (United States)

    Ross, Zev; Kheirbek, Iyad; Clougherty, Jane E; Ito, Kazuhiko; Matte, Thomas; Markowitz, Steven; Eisl, Holger

    2011-11-01

    Epidemiological studies have linked both noise and air pollution to common adverse health outcomes such as increased blood pressure and myocardial infarction. In urban settings, noise and air pollution share important sources, notably traffic, and several recent studies have shown spatial correlations between noise and air pollution. The temporal association between these exposures, however, has yet to be thoroughly investigated despite the importance of time series studies in air pollution epidemiology and the potential that correlations between these exposures could at least partly confound statistical associations identified in these studies. An aethelometer, for continuous elemental carbon measurement, was co-located with a continuous noise monitor near a major urban highway in New York City for six days in August 2009. Hourly elemental carbon measurements and hourly data on overall noise levels and low, medium and high frequency noise levels were collected. Hourly average concentrations of fine particles and nitrogen oxides, wind speed and direction and car, truck and bus traffic were obtained from nearby regulatory monitors. Overall temporal patterns, as well as day-night and weekday-weekend patterns, were characterized and compared for all variables. Noise levels were correlated with car, truck, and bus traffic and with air pollutants. We observed strong day-night and weekday-weekend variation in noise and air pollutants and correlations between pollutants varied by noise frequency. Medium and high frequency noise were generally more strongly correlated with traffic and traffic-related pollutants than low frequency noise and the correlation with medium and high frequency noise was generally stronger at night. Correlations with nighttime high frequency noise were particularly high for car traffic (Spearman rho=0.84), nitric oxide (0.73) and nitrogen dioxide (0.83). Wind speed and direction mediated relationships between pollutants and noise. Noise levels are

  16. Long-range transport of persistent pollutants into Arctic regions; Schadstoff-Ferntransport in die Arktis

    Energy Technology Data Exchange (ETDEWEB)

    Kallenborn, R.; Herzke, D. [Norwegian Inst. for Air Research, The Polar Environmental Centre, Tromso (Norway)

    2001-07-01

    In recent years, high concentrations of persistent pollutants (organic chemicals, metals) were detected in top predators of the Arctic food chain and indigenous peoples from the Canadian and Greenland Arctic, although no local contamination sources are known. The comprehensive, scientific investigations of the past 20 years confirmed that the combination of atmospheric and waterborne long-range transport is the major source of the high concentrations of persistent organic pollutants (POPs) in the pristine Arctic environment. However, also pelagic marine organisms (e.g. Atlantic cod, marine mammals) can transport large amounts of persistent pollutants in their lipids and introduce contaminants into the Arctic food web. Thus, the pollutants are transported into the Arctic and subsequently accumulated through the short and unbranched Arctic food web of the top predators. The most accepted theory nowadays describes the long-range transport of persistent pollutants as a combination of atmospheric and sea current transport, or as a 'global distillation' process. Depending on such physical properties of the substances as vapour pressure and the ambient temperature, persistent (semivolatile) contaminants are transported over different distances prior to deposition (sea surface, sediment, soil). After the deposition, however, and depending on the weather conditions and surrounding temperature, persistent pollutants will be re-evaporated into the atmosphere and undergo further atmospheric transport to the Arctic region. This process is also called the 'grasshopper effect'. The global transport of persistent pollutants into Arctic regions can be described as a repeatedly occurring combination of atmospheric and waterborne transport in which the main transport vehicle depends on the physical properties of the transported compound. The role of characteristic meteorological conditions in the respective climate zones through which the contaminant is

  17. High efficient multifunctional Ag{sub 3}PO{sub 4} loaded hydroxyapatite nanowires for water treatment

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yaling; Zhou, Hangyu; Zhu, Genxing [Center for Biomaterials and Biopathways, Department of Chemistry, Zhejiang University, Hangzhou (China); Shao, Changyu; Pan, Haihua; Xu, Xurong [Center for Biomaterials and Biopathways, Department of Chemistry, Zhejiang University, Hangzhou (China); Qiushi Academy for Advanced Studies, Zhejiang University (China); Tang, Ruikang, E-mail: rtang@zju.edu.cn [Center for Biomaterials and Biopathways, Department of Chemistry, Zhejiang University, Hangzhou (China); Qiushi Academy for Advanced Studies, Zhejiang University (China)

    2015-12-15

    Highlights: • The multifunctional Ag{sub 3}PO{sub 4} loaded hydroxyapatite (HAP) nanowires were synthesized via a facile in-situ precipitation method. • By optimizing the initial concentration of AgNO{sub 3}, the well-distributed Ag{sub 3}PO{sub 4}/HAP composites could be achieved. • The Ag{sub 3}PO{sub 4}/HAP composites showed excellent photocatalytic performance for the decomposition of dyes under visible light irradiation. • The maximum absorption capacity of the Ag{sub 3}PO{sub 4}/HAP composites for Pb(II) was 250 mg/g, approximately three times as that of pure HAP. • The Ag{sub 3}PO{sub 4}/HAP composites also exhibited excellent antibacterial activities even at relative low concentrations. - Abstract: Organic, inorganic, and biological pollutants are typical water contaminants and they seriously affect water quality. In this study, we suggested that a novel multifunctional Ag{sub 3}PO{sub 4} loaded hydroxyapatite (HAP) material can remove the typical pollutants from water. The Ag{sub 3}PO{sub 4}/HAP composites were synthesized facilely via in-situ precipitation of Ag{sub 3}PO{sub 4} on the pre-existing HAP nanowires. By optimizing the composition of Ag{sub 3}PO{sub 4} and HAP, the material could achieve an optimal photocatalytic activity to decompose rhodamine B (RhB), methyl orange (MO) and methylene blue (MB) under visible light irradiations with enhanced pH stability. Besides, the adsorption of Pb(II) on the Ag{sub 3}PO{sub 4}/HAP reached a maximum capacity of 250 mg/g and this value was approximately three times as that of pure HAP. Furthermore, the composite material exhibited excellent antibacterial activities towards gram-negative bacterium (Escherichia coli) and gram-positive bacterium (Stphylococcus aureus). The results highlighted the cooperative effect between Ag{sub 3}PO{sub 4} and hydroxyapatite (HAP). The simultaneous removals of dyes, toxic metal ions, and bacteria with a high efficiency followed an easy approach for the purification

  18. A High Precision Artificial Neural Networks Model for Short-Term Energy Load Forecasting

    Directory of Open Access Journals (Sweden)

    Ping-Huan Kuo

    2018-01-01

    Full Text Available One of the most important research topics in smart grid technology is load forecasting, because accuracy of load forecasting highly influences reliability of the smart grid systems. In the past, load forecasting was obtained by traditional analysis techniques such as time series analysis and linear regression. Since the load forecast focuses on aggregated electricity consumption patterns, researchers have recently integrated deep learning approaches with machine learning techniques. In this study, an accurate deep neural network algorithm for short-term load forecasting (STLF is introduced. The forecasting performance of proposed algorithm is compared with performances of five artificial intelligence algorithms that are commonly used in load forecasting. The Mean Absolute Percentage Error (MAPE and Cumulative Variation of Root Mean Square Error (CV-RMSE are used as accuracy evaluation indexes. The experiment results show that MAPE and CV-RMSE of proposed algorithm are 9.77% and 11.66%, respectively, displaying very high forecasting accuracy.

  19. Estimation of the Pollution Level in El Timsah Lake, Egypt

    International Nuclear Information System (INIS)

    Abd El Samie, S.G.; Hassan, H.B.; Hamza, M.S.

    2008-01-01

    The wide range of activities surrounding El Timsah Lake and the discharge effluent at the north and eastern parts of the lake led to high level of anthropogenic pollution in lake water more than the navigation activities. Heavy metals concentration increases in low salinity water toward the land from the discharging effluent. Whereas, oil hydrocarbon and water salinity increase toward Suez Canal current water. This indicates some dispersion of oil ballast water of shipping tankers or from petroleum companies during transportation in the Suez Canal. Chemical and isotopic results indicate lake water stratification, low mixing rate due to slow current of lake water. This led to long residence time of the pollution load enhancing accumulation and precipitation of the heavy metals to the bottom sediment near the boundaries of the lake

  20. A comparison of Reactivity Controlled Compression Ignition (RCCI) and Gasoline Compression Ignition (GCI) strategies at high load, low speed conditions

    International Nuclear Information System (INIS)

    Kavuri, Chaitanya; Paz, Jordan; Kokjohn, Sage L.

    2016-01-01

    Highlights: • Targeting high load-low speed, optimizations of RCCI and GCI strategies were performed. • The two strategies were compared in terms of performance, controllability and stability. • The optimum cases had high gross indicated efficiency (∼47%) and low NOx emissions. • RCCI strategy showed better combustion control but had higher soot emissions. • GCI strategy was relatively more sensitive to fluctuations in charge conditions. - Abstract: Past research has shown that Reactivity Controlled Compression Ignition (RCCI) and Gasoline Compression Ignition (GCI) combustion are promising approaches to improve efficiency and reduce pollutant emissions. However, the benefits have generally been confined to mid-load operating conditions. To enable practical application, these approaches must be able to operate over the entire engine map. A particularly challenging area is high load, low speed operation. Accordingly, the present work uses detailed CFD modeling and engine experiments to compare RCCI and GCI combustion strategies at a high load, low speed condition. Computational optimizations of RCCI and GCI combustion were performed at 20 bar gross indicated mean effective pressure (IMEP) and 1300 rev/min. The optimum points from the two combustion strategies were verified using engine experiments and were used to make the comparisons between RCCI and GCI combustion. The comparison showed that both the strategies had very similar combustion characteristics with a near top dead center injection initiating combustion. A parametric study was performed to identify the key input parameters that control combustion for the RCCI and GCI strategies. For both strategies, the combustion phasing could be controlled by the start of injection (SOI) timing of the near TDC injection. The short ignition delay of diesel fuel gave the RCCI strategy better control over combustion than the GCI strategy, but also had a simultaneous tradeoff with soot emissions. With the GCI

  1. Mirror benders for high thermal loading

    International Nuclear Information System (INIS)

    Bailey, W.; Vickery, A.P.

    1983-01-01

    The thermal conditions in high power mirrors can be very complex and the exact calculation of their thermal behaviour requires very detailed calculations. However by making some simplifying assumptions it is possible to make an analysis which indicates the sort of performance that can be expected. Further by consideration of the simplifying assumptions it is possible to see how the design may contain features to mitigate the effects that occur in the real world. A simple treatment of thermal perturbations in mirror benders is presented. The design features which can help a bender to operate with a high thermal flux are looked at. In conclusion, the way to proceed to higher thermal loadings when passive methods prove inadequate is suggested. (author)

  2. Power quality improvement in highly varying loads using thyristor-switched capacitor

    Energy Technology Data Exchange (ETDEWEB)

    Poshtan, M. [Petroleum Inst., Abu Dhabi (United Arab Emirates). Dept. of Electrical Engineering; Mokhtari, H.; Esmaeili, A. [Sharif Univ. of Technology, Tehran (Iran, Islamic Republic of). Dept. of Electrical Engineering

    2007-07-01

    Ordinary contactor-based-capacitor (CBC) banks may not be able to response quickly enough in highly varying electrical loads such as welding machines or arc furnace loads. Thyristor-switched capacitor (TSC) banks are therefore used to compensate for reactive power of highly varying loads. In this paper, the performance of a TSC was compared to CBC banks. The 2 systems, were also compared in terms of energy saving in transmission systems. Simulations carried out using PSCAD/EMTDC software showed that there was a considerable difference in the performance of the 2 systems. The shortcomings of existing CBC systems include slow response of mechanical switching systems; problem of switching more than one bank into the system; and, voltage/current transients during on-off switching. 3 refs., 6 tabs., 14 figs.

  3. [Use of macroalgae for the evaluation of organic pollution in the Preto river, northwest of São Paulo State].

    Science.gov (United States)

    Necchi Júnior, O; Branco, H Z; Dip, M R

    1994-01-01

    The Preto River, located in the northwest of São Paulo State, receives a total wastewater load of 15.150 kg DBO day-1, from which 13.685 kg DBO day-1 (90.5%) corresponds to domestic sewage, and the city of São José do Rio Preto contributes with 12.400 kg DBO day-1 (90% of domestic sewage). During the period from August 1990 through January 1991, monthly sampling was carried out to evaluate the use of macroalgae as bioindicator of organic pollution. Five sampling sites were established along the main river and the following variables were analised: temperature, conductance, turbidity, dissolved oxygen, BOD, COD, total and fecal coliforms, and composition and abundance of macroalgal communities. Data were submitted to analysis of variance, correlation coefficient, cluster analysis (four different approaches) and converted to biological indices (species deficit, relative pollution, saprobity, diversity and uniformity indices). A wide range in water quality was found (particularly for conductance, oxygen, BOD and COD) among the sampling sites, which were classified into three groups (polluted, moderately polluted and unpolluted/weakly polluted). As regards the occurrence and abundance of macroalgae the Rhodophyta were found only in unpolluted or weakly polluted sites, whereas Cyanophyta occurred mostly under high pollution load; the Chlorophyta species were observed under a wide range of conditions. Among the biological indices, saprobity was the most sensitive and correlated to all water variables and the other indices. Cluster analyses showed that the composition of macroalgal communities was consistent with the levels of organic pollution in the Preto River.

  4. Glycol-Substitute for High Power RF Water Loads

    CERN Document Server

    Ebert, Michael

    2005-01-01

    In water loads for high power rf applications, power is dissipated directly into the coolant. Loads for frequencies below approx. 1GHz are ordinarily using an ethylene glycol-water mixture as coolant. The rf systems at DESY utilize about 100 glycol water loads with powers ranging up to 600kW. Due to the increased ecological awareness, the use of glycol is now considered to be problematic. In EU it is forbidden to discharge glycol into the waste water system. In case of cooling system leakages one has to make sure that no glycol is lost. Since it is nearly impossible to avoid any glycol loss in large rf systems, a glycol-substitute was searched for and found. The found sodium-molybdate based substitute is actually a additive for corrosion protection in water systems. Sodium-molybdate is ecologically harmless; for instance, it is also used as fertilizer in agriculture. A homoeopathic dose of 0.4% mixed into deionised water gives better rf absorption characteristics than a 30% glycol mixture. The rf coolant feat...

  5. A 2-megawatt load for testing high voltage DC power supplies

    International Nuclear Information System (INIS)

    Horan, D.; Kustom, R.; Ferguson, M.; Primdahl, K.

    1993-01-01

    A high power water-cooled resistive load, capable of dissipating 2 Megawatts at 95 kilovolts is being designed and built. The load utilizes wirewound resistor elements suspended inside insulating tubing contained within a pressure vessel which is supplied a continuous flow of deionized water for coolant. A sub-system of the load is composed of non-inductive resistor elements in an oil tank. Power tests conducted on various resistor types indicate that dissipation levels as high as 22 times the rated dissipation in air can be achieved when the resistors are placed in a turbulent water flow of at least 15 gallons per minute. Using this data, the load was designed using 100 resistor elements in a series arrangement. A single-wall 316 stainless steel pressure vessel with flanged torispherical heads is built to contain the resistor assembly and deionized water. The resistors are suspended within G-11 tubing which span the cylindrical length of the vessel. These tubes are supported by G-10 baffles which also increase convection from the tubes by promoting turbulence within the surrounding water

  6. [Assessment of heavy metal pollution and potential ecological risks of urban soils in Kaifeng City, China].

    Science.gov (United States)

    Li, Yi-Meng; Ma, Jian-Hua; Liu, De-Xin; Sun, Yan-Li; Chen, Yan-Fang

    2015-03-01

    Ninety-nine topsoil (0-15 cm) samples were collected from Kaifeng City, China using the grid method, and then the concentrations of As, Cd, Cr, Cu, Ni, Pb and Zn in the samples were measured by standard methods. Soil pollution levels and potential ecological risks of the heavy metals were assessed using the pollution load index (PLI) and potential ecological risk index (RI), respectively. Ordinary Kriging interpolation technique was employed to investigate the spatial distribution of PLI and RI of the city. The results showed that high pollution of Cd occurred in Kaifeng urban soils, and there was moderate pollution of Zn, slight pollution of Pb and Cu, and no pollution of Ni, Cr and As. Very high ecological risk was posed by Cd and low risk by other metals. The mean PLI of the 7 metals from all sample points was 2.53, which was categorized as moderate pollution. The average RI was 344.58 which represented a considerable ecological risk. PLI and RI shared a similar spatial distribution with high values centralized in the old industrial area in the southeast and railway stations for passengers and goods in the south of the city, followed by the old town within the ancient city wall, and low values located in the north and west areas. Cadmium was the main factor for both soil pollution and potential ecological risk primarily due to farmland topsoil in the eastern suburb of Kaifeng City with high Cd concentrations resulted from sewage irrigation deposited in the urban area by wind, human activities such as soot discharged from the chemical fertilizer plant of Kaifeng, transportation and coal combustion.

  7. Acute pollution of recipients in urban areas

    DEFF Research Database (Denmark)

    Rauch, W.; Harremoës, P.

    1997-01-01

    Oxygen and ammonia concentration are key parameters of acute water pollution in urban rivers. These two abiotic parameters are statistically assessed for a historical rain series by means of a simplified deterministic model of the integrated drainage system. Continuous simulation of the system...... performance indicates that acute water pollution is caused by intermittent discharges from both sewer system and wastewater treatment plant. Neglecting one of them in the evaluation of the environmental impact gives a wrong impression of total system behavior. Detention basins and alternative operational...... modes in the treatment plant under wet weather loading have a limited positive effect for minimizing acute water pollution. (C) 1997 IAWQ. Published by Elsevier Science Ltd....

  8. Marine pollution in Cameroon (Gulf of Guinea): State and remedies for successful control and monitoring

    International Nuclear Information System (INIS)

    Folack, J.

    1999-01-01

    This paper analyses the various research results obtained over several years in Cameroon on coastal and marine pollution, especially pollution by solid wastes, industrial and domestic effluents, hydrocarbons (tar balls), heavy metals and pesticides. Values in the order of 175,531 and 194,685 tons have been estimated for annual pollution loads in terms of BOD and suspended matter respectively. With respect to BOD, the most polluting industries are petroleum refineries, food processing and chemical industries which respectively represent 38, 36 and 10% of the total annual BOD. Measurement of tar balls on various Cameroonian beaches shows values as high as 42.40 g/m 2 of beach, while the concentration of heavy metals encountered in shrimps and fish consumed in Cameroon shows a very wide range of values. Most of these values are similar to those obtained within the region, and some are alarming in their magnitude

  9. The effect of nitrogen additions on oak foliage and herbivore communities at sites with high and low atmospheric pollution

    International Nuclear Information System (INIS)

    Eatough Jones, Michele; Paine, Timothy D.; Fenn, Mark E.

    2008-01-01

    To evaluate plant and herbivore responses to nitrogen we conducted a fertilization study at a low and high pollution site in the mixed conifer forests surrounding Los Angeles, California. Contrary to expectations, discriminant function analysis of oak herbivore communities showed significant response to N fertilization when atmospheric deposition was high, but not when atmospheric deposition was low. We hypothesize that longer-term fertilization treatments are needed at the low pollution site before foliar N nutrition increases sufficiently to affect herbivore communities. At the high pollution site, fertilization was also associated with increased catkin production and higher densities of a byturid beetle that feeds on the catkins of oak. Leaf nitrogen and nitrate were significantly higher at the high pollution site compared to the low pollution site. Foliar nitrate concentrations were positively correlated with abundance of sucking insects, leafrollers and plutellids in all three years of the study. - Nitrogen additions at sites impacted by air pollution were associated with altered foliar herbivore communities and increased densities of a catkin-feeding beetle on Quercus kellogii

  10. Gasoline Engine HCCI Combustion - Extending the high load limit

    Energy Technology Data Exchange (ETDEWEB)

    Dahl, Daniel

    2012-07-01

    There is an increasing global focus on reducing emissions of greenhouse gases. For the automotive industry this means reducing CO2 emissions of the vehicles manufactured, which is synonymous with reducing their fuel consumption or adapting them for using renewable fuels. This thesis is based on a project aimed at improving the efficiency of gasoline engines in the lower load/speed region. The focus was mainly on a combustion strategy called homogeneous charge compression ignition (HCCI), but also on homogeneous lean and stratified lean spark-ignited combustion. In contrast to traditional stoichiometric spark-ignited combustion, HCCI can operate with diluted mixtures, which leads to better cycle efficiency, smaller pumping losses and smaller heat losses. However, at relatively high loads, HCCI combustion becomes excessively rapid, generating in-cylinder pressure oscillations (ringing), which are perceived as noise by the human ear. The main objective of the project was to identify ways to avoid this ringing behaviour in order to increase the upper load limit of HCCI. This is vital to avoid the need for mode switches to spark-ignited combustion at higher loads and to operate the engine as much as possible in the more effective HCCI mode. The strategy for reducing ringing investigated most extensively in the project was charge stratification, achieved by injecting part of the fuel late in the compression stroke. Available literature on effects of this strategy gave conflicting indications, both positive and negative effects have been reported, depending on the type of fuel and engine used. It was soon found that the strategy is effective for reducing ringing, but with resulting increases of NOX emissions. Further, in order for the strategy to be effective, global air/fuel ratios must not be much leaner than stoichiometric. The increases in NOX emissions were countered by shifting the ratio towards stoichiometric using exhaust gas recirculation (EGR), allowing a three

  11. High thermal load structure

    International Nuclear Information System (INIS)

    Tsujimura, Seiichi; Toyota, Masahiko.

    1995-01-01

    A highly thermal load structure applied to a plasma-opposed equipment of a thermonuclear device comprises heat resistant protection tiles and a cooling tube disposed in the protection tiles. As the protection tiles, a carbon/carbon composite material is used. The carbon/carbon composite material on the heat receiving surface comprises carbon fibers disposed in one direction (one dimensionally) arranged from the heat receiving surface toward the cooling tube. The carbon/carbon composite material on the side opposite to the heat receiving surface comprises carbon fibers arranged two-dimensionally in the direction perpendicular to the longitudinal direction of the cooling tube. Then, the cooling tube is interposed between the one-dimensional carbon/carbon composite material and the two-dimensional carbon/carbon composite material, and they are joined with each other by vacuum brazing. This can improve heat removing performance. In addition, thermal stresses at the joined portion is reduced. Further, electromagnetic force generated in the thermonuclear device is reduced. (I.N.)

  12. High thermal load structure

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Seiichi; Toyota, Masahiko

    1995-06-16

    A highly thermal load structure applied to a plasma-opposed equipment of a thermonuclear device comprises heat resistant protection tiles and a cooling tube disposed in the protection tiles. As the protection tiles, a carbon/carbon composite material is used. The carbon/carbon composite material on the heat receiving surface comprises carbon fibers disposed in one direction (one dimensionally) arranged from the heat receiving surface toward the cooling tube. The carbon/carbon composite material on the side opposite to the heat receiving surface comprises carbon fibers arranged two-dimensionally in the direction perpendicular to the longitudinal direction of the cooling tube. Then, the cooling tube is interposed between the one-dimensional carbon/carbon composite material and the two-dimensional carbon/carbon composite material, and they are joined with each other by vacuum brazing. This can improve heat removing performance. In addition, thermal stresses at the joined portion is reduced. Further, electromagnetic force generated in the thermonuclear device is reduced. (I.N.).

  13. Influence of land use configurations on river sediment pollution.

    Science.gov (United States)

    Liu, An; Duodu, Godfred O; Goonetilleke, Ashantha; Ayoko, Godwin A

    2017-10-01

    Land use is an influential factor in river sediment pollution. However, land use type alone is found to be inadequate to explain pollutant contributions to the aquatic environment since configurations within the same land use type such as land cover and development layout could also exert an important influence. Consequently, this paper discusses a research study, which consisted of an in-depth investigation into the relationship between land use type and river sediment pollution by introducing robust parameters that represent configurations within the primary land use types. Urban water pollutants, namely, nutrients, total carbon, polycyclic aromatic hydrocarbons and metals were investigated in the study. The outcomes show that higher patch density and more diverse land use development forms contribute relatively greater pollutant loads to receiving waters and consequently leading to higher sediment pollution. The study outcomes are expected to contribute essential knowledge for creating robust management strategies to minimise waterway pollution and thereby protect the health of aquatic ecosystems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. High voltage load resistor array

    Science.gov (United States)

    Lehmann, Monty Ray [Smithfield, VA

    2005-01-18

    A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

  15. Decree 149/013. It dictate norms standards for pollution prevention in the oil loading terminals, repairing ports and other ports where ships have hidrocarbon waste, to discharge in accordance with existing international agreements concluded with the international maritime organization ratification and ratified by our country

    International Nuclear Information System (INIS)

    2013-01-01

    This decree is about the standards concerning to the pollution prevention in the oil loading terminals.The countries involved in the agreement are committed to ensure that the oil loading terminals and ports have appropriate facilities for the reception of waste and oily mixtures.

  16. Calculation and analysis of the non-point source pollution in the upstream watershed of the Panjiakou Reservoir, People's Republic of China

    Science.gov (United States)

    Zhang, S.; Tang, L.

    2007-05-01

    Panjiakou Reservoir is an important drinking water resource in Haihe River Basin, Hebei Province, People's Republic of China. The upstream watershed area is about 35,000 square kilometers. Recently, the water pollution in the reservoir is becoming more serious owing to the non-point pollution as well as point source pollution on the upstream watershed. To effectively manage the reservoir and watershed and develop a plan to reduce pollutant loads, the loading of non-point and point pollution and their distribution on the upstream watershed must be understood fully. The SWAT model is used to simulate the production and transportation of the non-point source pollutants in the upstream watershed of the Panjiakou Reservoir. The loadings of non-point source pollutants are calculated for different hydrologic years and the spatial and temporal characteristics of non-point source pollution are studied. The stream network and topographic characteristics of the stream network and sub-basins are all derived from the DEM by ArcGIS software. The soil and land use data are reclassified and the soil physical properties database file is created for the model. The SWAT model was calibrated with observed data of several hydrologic monitoring stations in the study area. The results of the calibration show that the model performs fairly well. Then the calibrated model was used to calculate the loadings of non-point source pollutants for a wet year, a normal year and a dry year respectively. The time and space distribution of flow, sediment and non-point source pollution were analyzed depending on the simulated results. The comparison of different hydrologic years on calculation results is dramatic. The loading of non-point source pollution in the wet year is relatively larger but smaller in the dry year since the non-point source pollutants are mainly transported through the runoff. The pollution loading within a year is mainly produced in the flood season. Because SWAT is a

  17. APS high heat load monochromator

    International Nuclear Information System (INIS)

    Lee, W.K.; Mills, D.

    1993-02-01

    This document contains the design specifications of the APS high heat load (HHL) monochromator and associated accessories as of February 1993. It should be noted that work is continuing on many parts of the monochromator including the mechanical design, crystal cooling designs, etc. Where appropriate, we have tried to add supporting documentation, references to published papers, and calculations from which we based our decisions. The underlying philosophy behind performance specifications of this monochromator was to fabricate a device that would be useful to as many APS users as possible, that is, the design should be as generic as possible. In other words, we believe that this design will be capable of operating on both bending magnet and ID beamlines (with the appropriate changes to the cooling and crystals) with both flat and inclined crystal geometries and with a variety of coolants. It was strongly felt that this monochromator should have good energy scanning capabilities over the classical energy range of about 4 to 20 keywith Si (111) crystals. For this reason, a design incorporating one rotation stage to drive both the first and second crystals was considered most promising. Separate rotary stages for the first and second crystals can sometimes provide more flexibility in their capacities to carry heavy loads (for heavily cooled first crystals or sagittal benders of second crystals), but their tuning capabilities were considered inferior to the single axis approach

  18. Direct FEM-computation of load carrying capacity of highly loaded passive components; Direkte FEM - Berechnung der Tragfaehigkeit hochbeanspruchter passiver Komponenten

    Energy Technology Data Exchange (ETDEWEB)

    Staat, M; Heitzer, M [Forschungszentrum Juelich GmbH (Germany). Inst. fuer Sicherheitsforschung und Reaktortechnik

    1998-11-01

    Detailed, inelastic FEM analyses yield accurate information about the stresses and deformations in passive components. The local loading conditions, however, cannot be directly compared with a limit load in terms of structural mechanics. Concentration on the load carrying capacity is an approach simplifying the analysis. Based on the plasticity theory, limit and shakedown analyses calculate the load carrying capacities directly and exactly. The paper explains the implementation of the limit and shakedown data sets in a general FEM program and the direct calculation of the load carrying capacities of passive components. The concepts used are explained with respect to common structural analysis. Examples assuming high local stresses illustrate the application of FEM-based limit and shakedown analyses. The calculated interaction diagrams present a good insight into the applicable operational loads of individual passive components. The load carrying analysis also opens up a structure mechanics-based approach to assessing the load-to-collapse of cracked components made of highly ductile fracture-resistant material. (orig./CB) [Deutsch] Genaue Kenntnis der Spannungen und Verformungen in passiven Komponenten gewinnt man mit detailierten inelastischen FEM Analysen. Die lokale Beanspruchung laesst sich aber nicht direkt mit einer Beanspruchbarkeit im strukturmechanischen Sinne vergleichen. Konzentriert man sich auf die Frage nach der Tragfaehigkeit, dann vereinfacht sich die Analyse. Im Rahmen der Plastizitaetstheorie berechnen Traglast- und Einspielanalyse die tragbaren Lasten direkt und exakt. In diesem Beitrag wird eine Implementierung der Traglast- und Einspielsaetze in ein allgemeines FEM Programm vorgestellt, mit der die Tragfaehigkeit passiver Komponenten direkt berechnet wird. Die benutzten Konzepte werden in Bezug auf die uebliche Strukturanalyse erlaeutert. Beispiele mit lokal hoher Beanspruchung verdeutlichen die Anwendung der FEM basierten Traglast- und

  19. Experimental studies of the dilution of vehicle exhaust pollutants by environment-protecting pervious pavement.

    Science.gov (United States)

    Liu, Chung-Ming; Chen, Jui-Wen; Tsai, Jen-Hui; Lin, Wei-Shian; Yen, M-T; Chen, Ting-Hao

    2012-01-01

    This study determines whether environment-protecting pervious pavement can dilute pollutants immediately after emissions from vehicle. The turbulence-driven dry-deposition process is too slow to be considered in this aspect. The pavement used is the JW pavement (according to its inventors name), a high-load-bearing water-permeable pavement with patents in over 100 countries, which has already been used for more than 8 years in Taiwan and is well suited to replacing conventional road pavement, making the potential implementation of the study results feasible. The design of this study included two sets of experiments. Variation of the air pollutant concentrations within a fenced area over the JW pavement with one vehicle discharging emissions into was monitored and compared with results over a non-JW pavement. The ambient wind speed was low during the first experiment, and the results obtained were highly credible. It was found that the JW pavement diluted vehicle pollutant emissions near the ground surface by 40%-87% within 5 min of emission; whereas the data at 2 m height suggested that about 58%-97% of pollutants were trapped underneath the pavement 20 min after emission. Those quantitative estimations may be off by +/- 10%, if errors in emissions and measurements were considered. SO2 and CO2 underwent the most significant reduction. Very likely, pollutants were forced to move underneath due to the special design of the pavement. During the second experiment, ambient wind speeds were high and the results obtained had less credibility, but they did not disprove the pollutant dilution capacity of the JW pavement. In order to track the fate of pollutants, parts of the pavement were removed to reveal a micro version of wetland underneath, which could possibly hold the responsibility of absorbing and decomposing pollutants to forms harmless to the environment and human health.

  20. Fabrication of interconnected microporous biomaterials with high hydroxyapatite nanoparticle loading

    International Nuclear Information System (INIS)

    Zhang Wei; Yao Donggang; Zhang Qingwei; Lelkes, Peter I; Zhou, Jack G

    2010-01-01

    Hydroxyapatite (HA) is known to promote osteogenicity and enhance the mechanical properties of biopolymers. However, incorporating a large amount of HA into a porous biopolymer still remains a challenge. In the present work, a new method was developed to produce interconnected microporous poly(glycolic-co-lactic acid) (PLGA) with high HA nanoparticle loading. First, a ternary blend comprising PLGA/PS (polystyrene)/HA (40/40/20 wt%) was prepared by melt blending under conditions for formation of a co-continuous phase structure. Next, a dynamic annealing stage under small-strain oscillation was applied to the blend to facilitate nanoparticle redistribution. Finally, the PS phase was sacrificially extracted, leaving a porous matrix. The results from different characterizations suggested that the applied small-strain oscillation substantially accelerated the migration of HA nanoparticles during annealing from the PS phase to the PLGA phase; nearly all HA particles were uniformly presented in the PLGA phase after a short period of annealing. After dissolution of the PS phase, a PLGA material with interconnected microporous structure was successfully produced, with a high HA loading above 30 wt%. The mechanisms beneath the experimental observations, particularly on the enhanced particle migration process, were discussed, and strategies for producing highly particle loaded biopolymers with interconnected microporous structures were proposed.

  1. Effect of depositional environment and sources of pollution on uranium concentration in sediment, coral, algae and seagrass species from the Gulf of Aqaba (Red Sea)

    International Nuclear Information System (INIS)

    Abu-Hilal, A.H.

    1994-01-01

    Uranium concentrations were determined in sediment samples, four hard and two soft corals, one seagrass and four species of algae collected from phosphate-polluted sites in the northern reef area of the Gulf of Aqaba. High uranium concentrations were found in all samples examined from a phosphate-polluted site near a phosphate loading berth compared to the unpolluted ones. Uranium levels, U/Ca ratios, concentration and discrimination factors were also high compared to those reported from other regions of the world. The effects of the exported raw phosphate powder as the main source of pollution and depositional environment on the concentration of uranium in the examined species are discussed. (Author)

  2. Pollution level assessment of road dust from islamabad expressway

    International Nuclear Information System (INIS)

    Faiz, Y.; Siddiqui, N.

    2013-01-01

    Thirteen road dust and four soil samples were analyzed using Instrumental Neutron Activation Analysis (INAA) and Flame Atomic Absorption Spectroscopy (FAAS) to determine the elemental composition of road dust collected from Islamabad Expressway. Pollution parameters and indicators such as Enrichment Factors (EFs), Pollution Load Index (PLI), Geoaccumulation Index (I G eo), Pollution Index (PI) and Integrated Pollution Index (IPI) were calculated and showed that the area around Islamabad Expressway is low to moderately polluted especially by elements such as Mg and Sb. The IPI of the elements was found to vary in the order; Mg>Sb>Cu>Sr ≅Pb>Ga>Na >Sn≅ Zn>Yb>Se>Hf. The 5 samples collected around the busy intersections of Faizabad and Zero Point have higher amounts of most of the elements determined. Moreover the pollution indices for these samples indicate that these sites are more contaminated than the remaining 8 sampling sites. (author)

  3. Investigating the effects of point source and nonpoint source pollution on the water quality of the East River (Dongjiang) in South China

    Science.gov (United States)

    Wu, Yiping; Chen, Ji

    2013-01-01

    Understanding the physical processes of point source (PS) and nonpoint source (NPS) pollution is critical to evaluate river water quality and identify major pollutant sources in a watershed. In this study, we used the physically-based hydrological/water quality model, Soil and Water Assessment Tool, to investigate the influence of PS and NPS pollution on the water quality of the East River (Dongjiang in Chinese) in southern China. Our results indicate that NPS pollution was the dominant contribution (>94%) to nutrient loads except for mineral phosphorus (50%). A comprehensive Water Quality Index (WQI) computed using eight key water quality variables demonstrates that water quality is better upstream than downstream despite the higher level of ammonium nitrogen found in upstream waters. Also, the temporal (seasonal) and spatial distributions of nutrient loads clearly indicate the critical time period (from late dry season to early wet season) and pollution source areas within the basin (middle and downstream agricultural lands), which resource managers can use to accomplish substantial reduction of NPS pollutant loadings. Overall, this study helps our understanding of the relationship between human activities and pollutant loads and further contributes to decision support for local watershed managers to protect water quality in this region. In particular, the methods presented such as integrating WQI with watershed modeling and identifying the critical time period and pollutions source areas can be valuable for other researchers worldwide.

  4. Effect of highly reflective roofing sheet on building thermal loads for a school in Osaka

    Directory of Open Access Journals (Sweden)

    Yuan Jihui

    2017-01-01

    Full Text Available Currently, urban heat island (UHI phenomenon and building energy consumptions are becoming serious. Strategies to mitigate UHI and reduce building energy consumptions are implemented worldwide. In Japan, as an effective means of mitigating UHI and saving energy of buildings, highly reflective (HR and green roofs are increasingly used. In order to evaluate the effect of roofs with high reflection and thermal insulation on the energy conservation of buildings, we investigated the roof solar reflectivity of the subject school in Osaka, in which the HR roofing sheet was installed on the roof from 2010. Thermal loads, including cooling and heating loads of the top floor of school, were calculated using the thermal load calculation software, New HASP/ACLD-β. Comparing the thermal loads after HR roofing sheet installation to previous, the annual thermal load decreased about 25 MJ/m2-year and the cooling load decreased about 112 MJ/m2-year. However, the heating load increased about 87 MJ/m2-year in winter. To minimize the annual thermal load, thermal insulation of the roof was also considered be used together with HR roofing sheet in this study. The results showed that the combination of HR roofing sheet and high thermal insulation is more effective to reduce the annual thermal load.

  5. Characteristic study of high-T{sub c} superconducting maglev under side-loading

    Energy Technology Data Exchange (ETDEWEB)

    Wang Wei [Applied Superconductivity Laboratory, M/S 152, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China)], E-mail: frank.weiwang@gmail.com; Wang Jiasu [Applied Superconductivity Laboratory, M/S 152, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China)], E-mail: asclab@asclab.cn; Liu Wei; Zheng Jun; Lin Qunxu; Pan Siting; Deng Zigang; Ma Guangtong; Wang Suyu [Applied Superconductivity Laboratory, M/S 152, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China)

    2009-02-15

    In practical application of High-T{sub c} Superconducting (HTS) maglev, slant is an observable defect. It was caused by constantly one side on and off the vehicle by passengers. So far, this phenomenon has not been reported yet. In order to understand its influence on the stability of the HTS maglev, we experimentally studied the dynamic characteristic and slant effect of HTS maglev under center-load and side-load. It was found that load destabilizes the vehicle, and the side-load can obviously slant the vehicle body. In the end, the pre-load method was proposed to enhance the dynamic stability and suppress the slant, which proved to be considerably effective. These results are critical in practical running of HTS maglev.

  6. Geochemical speciation and pollution assessment of heavy metals in surface sediments from Nansi Lake, China.

    Science.gov (United States)

    Yang, Liyuan; Wang, Longfeng; Wang, Yunqian; Zhang, Wei

    2015-05-01

    Sixteen surface sediment samples were collected from Nansi Lake to analyze geochemical speciation of heavy metals including Cd, As, Pb, Cr, and Zn, assess their pollution level, and determine the spatial distribution of the non-residual fraction. Results showed that Cd had higher concentrations in water-soluble and exchangeable fractions. As and Pb were mainly observed as humic acid and reducible fractions among the non-residual fractions, while Cr and Zn were mostly locked up in a residual fraction. The mean pollution index (P i) values revealed that the lower lake generally had a higher enrichment degree than the upper lake. Cd (2.73) and As (2.05) were in moderate level of pollution, while the pollution of Pb (1.80), Cr (1.27), and Zn (1.02) appeared at low-level pollution. The calculated pollution load index (PLI) suggested the upper lake suffered from borderline moderate pollution, while the lower lake showed moderate to heavy pollution. Spatial principle component analysis showed that the first principal component (PC1) including Cd, As, and Pb could explain 56.18 % of the non-residual fraction. High values of PC1 were observed mostly in the southern part of Weishan Lake, which indicated greater bioavailability and toxicity of Cd, As, and Pb in this area.

  7. Increasing alpine transit traffic through Switzerland will considerably enhance high altitude alpine pollutant levels

    Energy Technology Data Exchange (ETDEWEB)

    Prevot, A S.H.; Dommen, J; Furger, M; Graber, W K [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    Within the EU-Project VOTALP (Vertical Ozone Transports in the Alps), we have shown that deep alpine valleys like the Mesolcina Valley very efficiently transport air out of the polluted valley up to altitudes between 2000 and near 4000 m asl (above sea level). Pollutants emitted in these valleys are very efficiently transported up to high altitudes. (author) 2 figs., 1 tab., 2 refs.

  8. Metal pollution investigation of Goldman Park, Middletown Ohio: Evidence for steel and coal pollution in a high child use setting.

    Science.gov (United States)

    Dietrich, Matthew; Huling, Justin; Krekeler, Mark P S

    2018-03-15

    A geochemical investigation of both ballfield sediment and street sediment in a park adjacent to a major steel manufacturing site in Middletown, Ohio revealed Pb, Cu, Cr and Zn exceeded background levels, but in heterogeneous ways and in varying levels of health concern. Pb, Sn, and Zn had geoaccumulation values>2 (moderate to heavy pollutants) in street sediment samples. Cr had a geoaccumulation value>1, while Ni, W, Fe and Mn had geoaccumulation values between 1 and 0 in street sediment. Street sediment contamination factors for respective elements are Zn (10.41), Sn (5.45), Pb (4.70), Sb (3.45), Cr (3.19), W (2.59), and Mn (2.43). The notable elements with the highest factors for ball fields are Zn (1.72), Pb (1.36), Cr (0.99), V (0.95), and Mn (1.00). High correlation coefficients of known constituents of steel, such as Fe and Mo, Ni and Cr, W and Co, W and V, as well as particulate steel and coal spherule fragments found by SEM suggest probable sourcing of some of the metals from the AK Steel facility directly adjacent to the park. However, overall extensive heterogeneity of metal pollutants in the area points to the difficulties in sourcing pollutant metals, with many outside sources likely contributing as well. This study demonstrates that different sediment media can be impacted by significantly different metal pollutants even when in very close proximity to a single source and points to unrecognized complexity in urban pollution processes in the region. This study pertains to large-scale regional importance, as Middletown, Ohio is indicative of a typical post-industrial Midwestern U.S. city where limited investigation has been conducted regarding urban pollution and sourcing of materials. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Efficiency and Loading Evaluation of High Efficiency Mist Eliminators (HEME) - 12003

    Energy Technology Data Exchange (ETDEWEB)

    Giffin, Paxton K.; Parsons, Michael S.; Waggoner, Charles A. [Institute for Clean Energy Technology, Mississippi State University, 205 Research Blvd Starkville, MS 39759 (United States)

    2012-07-01

    High efficiency mist eliminators (HEME) are filters primarily used to remove moisture and/or liquid aerosols from an air stream. HEME elements are designed to reduce aerosol and particulate load on primary High Efficiency Particulate Air (HEPA) filters and to have a liquid particle removal efficiency of approximately 99.5% for aerosols down to sub-micron size particulates. The investigation presented here evaluates the loading capacity of the element in the absence of a water spray cleaning system. The theory is that without the cleaning system, the HEME element will suffer rapid buildup of solid aerosols, greatly reducing the particle loading capacity. Evaluation consists of challenging the element with a waste surrogate dry aerosol and di-octyl phthalate (DOP) at varying intervals of differential pressure to examine the filtering efficiency of three different element designs at three different media velocities. Also, the elements are challenged with a liquid waste surrogate using Laskin nozzles and large dispersion nozzles. These tests allow the loading capacity of the unit to be determined and the effectiveness of washing down the interior of the elements to be evaluated. (authors)

  10. High Heat Load Properties of Ultra Fine Grain Tungsten

    International Nuclear Information System (INIS)

    Zhou, Z.; Du, J.; Ge, C.; Linke, J.; Pintsuk, G.; Song, S.X.

    2007-01-01

    Full text of publication follows: Tungsten is increasingly considered as a promising candidate armour materials facing the plasma in tokamaks for medium to high heat flux components (EAST, ASDEX, ITER). Fabrication tungsten with ultra fine grain size is considered as an effective way to ameliorate some disadvantages of tungsten, such as its brittleness at room temperature. But the research data on the performance of ultra fine grain tungsten is still very limit. In this work, high heat load properties of pure ultra-fine grain tungsten have been studied. The ultra fine grain tungsten samples with average grain size of 0.2 μm, 1 μm and 3 μm were fabricated by resistance sintering under ultra high pressure. The annealing experiments for the investigation of the material resistance against grain growth have been done by annealing samples in a vacuum furnace at different temperature holding for 2 hours respectively. It is found that recrystallization and grain growth occur at heating temperature of 1250 deg. c. The finer the initial grain sizes of tungsten, the smaller its grain growth grain. The effects of transient high thermal loads (off normal events like disruptions) on tungsten surface morphology have been performed in electron beam test facility JUDITH. The thermal loads tests have been carried out with 4 ms pulses at different power density of 0.22, 0.33, 0.44, 0.55 and 0.88 GW/m 2 respectively. Horizontal cracks formed for all tungsten samples at 0.44 GW/m 2 . Particle erosions occurred for tungsten with 3 μm size at 0.33 GW/m 2 and for tungsten with 0.2 and 1 μm size at 0.55 GW/m 2 . The weight loss of tungsten with 0.2, 1 and 3 μm size are 2,0.1,0.6 mg respectively at 0.88 GW/m 2 . The effects of a large number of very short transient repetitive thermal loads (ELM-like) on tungsten surface morphology also have been performed by using a fundamental wave of a YAG laser. It is found that tungsten with 0.2 μm size has the best performance. (authors)

  11. High Heat Load Properties of Ultra Fine Grain Tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Z.; Du, J.; Ge, C. [Lab. of Special Ceramic and P/M, University of Science and Technology, 100083 Beijing (China); Linke, J.; Pintsuk, G. [FZJ-Forschungszentrum Juelich GmbH, Association Euratom-FZJ, Institut fur Plasmaphysik, Postfach 1913, D-52425 Juelich (Germany); Song, S.X. [Research Center on Fusion Materials (RCFM), University of Science and Technology Beijing (USTB), 100083 Beijing (China)

    2007-07-01

    Full text of publication follows: Tungsten is increasingly considered as a promising candidate armour materials facing the plasma in tokamaks for medium to high heat flux components (EAST, ASDEX, ITER). Fabrication tungsten with ultra fine grain size is considered as an effective way to ameliorate some disadvantages of tungsten, such as its brittleness at room temperature. But the research data on the performance of ultra fine grain tungsten is still very limit. In this work, high heat load properties of pure ultra-fine grain tungsten have been studied. The ultra fine grain tungsten samples with average grain size of 0.2 {mu}m, 1 {mu}m and 3 {mu}m were fabricated by resistance sintering under ultra high pressure. The annealing experiments for the investigation of the material resistance against grain growth have been done by annealing samples in a vacuum furnace at different temperature holding for 2 hours respectively. It is found that recrystallization and grain growth occur at heating temperature of 1250 deg. c. The finer the initial grain sizes of tungsten, the smaller its grain growth grain. The effects of transient high thermal loads (off normal events like disruptions) on tungsten surface morphology have been performed in electron beam test facility JUDITH. The thermal loads tests have been carried out with 4 ms pulses at different power density of 0.22, 0.33, 0.44, 0.55 and 0.88 GW/m{sup 2} respectively. Horizontal cracks formed for all tungsten samples at 0.44 GW/m{sup 2}. Particle erosions occurred for tungsten with 3 {mu}m size at 0.33 GW/m{sup 2} and for tungsten with 0.2 and 1 {mu}m size at 0.55 GW/m{sup 2}. The weight loss of tungsten with 0.2, 1 and 3 {mu}m size are 2,0.1,0.6 mg respectively at 0.88 GW/m{sup 2}. The effects of a large number of very short transient repetitive thermal loads (ELM-like) on tungsten surface morphology also have been performed by using a fundamental wave of a YAG laser. It is found that tungsten with 0.2 {mu}m size has

  12. High Mass Loading MnO2 with Hierarchical Nanostructures for Supercapacitors.

    Science.gov (United States)

    Huang, Zi-Hang; Song, Yu; Feng, Dong-Yang; Sun, Zhen; Sun, Xiaoqi; Liu, Xiao-Xia

    2018-04-24

    Metal oxides have attracted renewed interest as promising electrode materials for high energy density supercapacitors. However, the electrochemical performance of metal oxide materials deteriorates significantly with the increase of mass loading due to their moderate electronic and ionic conductivities. This limits their practical energy. Herein, we perform a morphology and phase-controlled electrodeposition of MnO 2 with ultrahigh mass loading of 10 mg cm -2 on a carbon cloth substrate to achieve high overall capacitance without sacrificing the electrochemical performance. Under optimum conditions, a hierarchical nanostructured architecture was constructed by interconnection of primary two-dimensional ε-MnO 2 nanosheets and secondary one-dimensional α-MnO 2 nanorod arrays. The specific hetero-nanostructures ensure facile ionic and electric transport in the entire electrode and maintain the structure stability during cycling. The hierarchically structured MnO 2 electrode with high mass loading yields an outstanding areal capacitance of 3.04 F cm -2 (or a specific capacitance of 304 F g -1 ) at 3 mA cm -2 and an excellent rate capability comparable to those of low mass loading MnO 2 electrodes. Finally, the aqueous and all-solid asymmetric supercapacitors (ASCs) assembled with our MnO 2 cathode exhibit extremely high volumetric energy densities (8.3 mWh cm -3 at the power density of 0.28 W cm -3 for aqueous ASC and 8.0 mWh cm -3 at 0.65 W cm -3 for all-solid ASC), superior to most state-of-the-art supercapacitors.

  13. PHOTOCHEMICAL AIR POLLUTION IN THE NORTH OF PORTUGAL: A HIGH TROPOSHERIC OZONE EPISODE

    Science.gov (United States)

    Monteiro, A.; Carvalho, A.; Tchepel, O.; Ferreira, J.; Martins, H.; Miranda, A.; Borrego, C.; Saavedra, S.; Rodríguez, A.; Souto, J. A.

    2009-12-01

    Very high concentrations of ozone are continuously measured at the monitoring station at Lamas d’Olo, located at the North of Portugal,. A particular high photochemical episode occurred between 11 and 13 of July 2005, registering ozone hourly maximum values above 350 µg.m-3. This ozone-rich episode is investigated in this paper, in order to identify its origin and formation. Besides the analysis of both meteorological and air quality monitoring datasets, a numerical modelling approach, based on MM5-CAMx system, was used to simulate the dispersion and transport (horizontal and vertical) of the photochemical pollutants and its precursors. A cross spectrum analysis of the meteorological and air quality time series was performed, in the frequency domain, to establish the relationships between ozone data measured at Lamas d’Olo with air quality data from neighbourhood stations and meteorological parameters. Results point out different behaviour/contribution between the analysed sites. Moreover, different contributions of the u and v wind component on the ozone concentration fluctuations were found suggesting the presence a mountain breeze circulation and a north synoptic transport. The preliminary modelling results pointed out that the vertical transport of pollutants are responsible for the measured high concentrations, combined with particular meteorological conditions, related to the planetary boundary layer (PBL) development. The pollutants transported and existent at high vertical levels are captured/trapped when the PBL height reaches its daily maximum, and extremely high ozone ground level concentrations are consequently measured.

  14. Combustion performance and pollutant emissions analysis using diesel/gasoline/iso-butanol blends in a diesel engine

    International Nuclear Information System (INIS)

    Wei, Mingrui; Li, Song; Xiao, Helin; Guo, Guanlun

    2017-01-01

    Highlights: • The diesel/gasoline/iso-butanol blends were investigated in a CI engine. • Blend with gasoline or iso-butanol produce higher HC emission. • CO increase at low loads and decrease at medium and high loads with blend fuels. • Gasoline or iso-butanol decrease large particles but increase small particles. • Blend fuels reduce total PM number and mass concentrations. - Abstract: In this study, the effects of diesel/gasoline/iso-butanol blends, including pure diesel (D100), diesel (70%)/gasoline (30%) (D70G30, by mass), diesel (70%)/iso-butanol (30%) (D70B30) and diesel (70%)/gasoline (15%)/iso-butanol (15%) (D70G15B15), on combustion and exhaust pollutant emissions characteristics in a four-cylinder diesel engine were experimentally investigated under various engine load conditions with a constant speed of 1800 rpm. The results indicated that D70G30, D70G15B15 and D70B30 delayed the ignition timing and shortened the combustion duration compared to D100. Additionally, CA50 was retarded when engine fuelled with D70G30, D70G15B15 and D70B30 at low engine load conditions, but it was advanced at medium and high engine loads. The maximum pressure rise rates (MPRRs) of D70G30, D70G15B15 and D70B30 were increased compared with D100 except for at engine load of 0.13 MPa BMEP (brake mean effective pressure). Meanwhile, D70G15B15 and D70B30 produced higher brake specific fuel consumption (BSFC) than that of D100. The effects of diesel blend with gasoline or iso-butanol on exhaust pollutant emissions were varied with loads. CO emissions were increased obviously and NOx emissions were decreased under low engine loads. However, CO emissions were decreased and NOx emissions were slightly increased under the medium and high engine load conditions. However, D70G30, D70G15B15 and D70B30 leaded to higher HC emissions than D100 regardless the variation of engine load. Moreover, the particulate matter (PM) (diameter, number and mass concentrations) emissions by using

  15. Dynamic influent pollutant disturbance scenario generation using a phenomenological modelling approach

    DEFF Research Database (Denmark)

    Gernaey, Krist; Flores Alsina, Xavier; Rosen, Christian

    2011-01-01

    : the larger the simulated sewer network, the smoother the simulated diurnal flow rate and concentration variations. In the discussion, it is pointed out how the proposed phenomenological models can be expanded to other applications, for example to represent heavy metal or organic micro-pollutant loads......Activated Sludge Models are widely used for simulation-based evaluation of wastewater treatment plant (WWTP) performance. However, due to the high workload and cost of a measuring campaign on a full-scale WWTP, many simulation studies suffer from lack of sufficiently long influent flow rate...... and concentration time series representing realistic wastewater influent dynamics. In this paper, a simple phenomenological modelling approach is proposed as an alternative to generate dynamic influent pollutant disturbance scenarios. The presented set of models is constructed following the principles of parsimony...

  16. Can We Manage Nonpoint-Source Pollution Using Nutrient Concentrations during Seasonal Baseflow?

    Directory of Open Access Journals (Sweden)

    James A. McCarty

    2016-05-01

    Full Text Available Nationwide, a substantial amount of resources has been targeted toward improving water quality, particularly focused on nonpoint-source pollution. This study was conducted to evaluate the relationship between nutrient concentrations observed during baseflow and runoff conditions from 56 sites across five watersheds in Arkansas. Baseflow and stormflow concentrations for each site were summarized using geometric mean and then evaluated for directional association. A significant, positive correlation was found for NO–N, total N, soluble reactive P, and total P, indicating that sites with high baseflow concentrations also had elevated runoff concentrations. Those landscape factors that influence nutrient concentrations in streams also likely result in increased runoff, suggesting that high baseflow concentrations may reflect elevated loads from the watershed. The results highlight that it may be possible to collect water-quality data during baseflow to help define where to target nonpoint-source pollution best management practices within a watershed.

  17. Soil mechanical stresses in high wheel load agricultural field traffic: a case study

    DEFF Research Database (Denmark)

    Lamandé, Mathieu; Schjønning, Per

    2017-01-01

    highly skewed. Across tyres, the maximum stress in the contact area correlated linearly with, but was much higher than, the mean ground pressure. For each of the three soil depths, the maximum stresses under the tyres were significantly correlated with the wheel load, but not with other loading......Subsoil compaction is a serious long-term threat to soil functions. Only a few studies have quantified the mechanical stresses reaching deep subsoil layers for modern high wheel load machinery. In the present study we measured the vertical stresses in the tyre–soil contact area and at 0.3, 0...

  18. Accumulation of Pollutants in Highway Detention Ponds

    DEFF Research Database (Denmark)

    Bentzen, Thomas Ruby

    single rain event. From the hindcast results it is possible to calculate mean water and pollutant loads. This method is commonly used in urban drainage systems for capacity analysis or for prediction of CSO's. The challenge is to develop a simplified and still accurate description of flow and transport......This PhD study deals with issues related to water and pollutant transport from highway surfaces caused by rain. It is essential in the study to apply methods and models in which improvements in relation to removal of pollutants can be identified and to be able to predict the yearly discharges....... Measurements of water and pollutant transport are carried out in different highway systems. A geometrically well-defined test pond is established, wherein the deposition of particulate matter can be measured. The result from the test pond is transferred to real detention ponds in which the three...

  19. Environmental Pollution: Causing High Morbidity and Mortality

    OpenAIRE

    , E. Laho; , G. Koduzi; , D. Osmanlli; , F. Aliu

    2016-01-01

    The environmental pollution which is increasing, it is a concerning issue for the community, and when it comes to big cities like Elbasan this is a hot spot. The relevant experience has shown that the more industrial and urban pollution an area has, the higher the pulmonary morbidity is and more cases of mortality from tumoral diseases are. To investigate and show the morbidity and mortality rate from respiratory diseases, cancer etc In our investigation which is a retrospective statistical r...

  20. Performance of an optimally contact-cooled high-heat-load mirror at the APS

    International Nuclear Information System (INIS)

    Cai, Z.; Khounsary, A.; Lai, B.; McNulty, I.; Yun, W.

    1998-01-01

    X-ray undulator beamlines at third-generation synchrotrons facilities use either a monochromator or a mirror as the first optical element. In this paper, the thermal and optical performance of an optimally designed contact-cooled high-heat-load x-ray mirror used as the first optical element on the 2ID undulator beamline at the Advanced Photon Source (APS) is reported. It is shown that this simple and economical mirror design can comfortably handle the high heat load of undulator beamlines and provide good performance with long-term reliability and ease of operation. Availability and advantages of such mirrors can make the mirror-first approach to high-heat-load beamline design an attractive alternative to monochromator-first beamlines in many circumstances

  1. Pollution load index for heavy metals in Mian-Ab plain soil, Khuzestan, Iran

    OpenAIRE

    Jorfi, Sahand; Maleki, Rohangiz; Jaafarzadeh, Neemat; Ahmadi, Mehdi

    2017-01-01

    Soil pollution by heavy metals is a major concern in agricultural area. Potential impact of heavy metals in agricultural soil on human health by accumulating in food chain demonstrated elsewhere.In this regard Mian-Ab plain as a major agricultural site of Khuzestan province considered for Arsenic, cadmium and lead concentration as the main potential toxic pollutants in soil. 50 topsoil samples were collected and analyzed by inductively coupled plasma mass spectrometry (ICP-MS). Also Contamina...

  2. The environment of nature reserves under anthropogenic load: air transport of pollution to the North of European Russia

    Science.gov (United States)

    Vinogradova, A. A.; Ivanova, Yu. A.; Veremeychik, A. O.

    2012-04-01

    Nature reserves are created to keep in their original states natural environment, flora and fauna of various ecological systems, territories, climatic zones, etc. Now natural objects everywhere exist under anthropogenic loading from man-made activities. It is impossible to avoid atmospheric or river transport of pollution to the environment of reserved territories. The main idea of the work is to analyze atmospheric transport of anthropogenic metals (Ni, Cu, Pb, Fe, Al), as well as of soot (black carbon - BC) from Russian large industrial areas (source-regions) to the territories of nature reserves at the North of European Russia - the Kostomukshsky reserve (KR) in Karelia (64.57°N, 30.67°E) and the Nenetzky reserve (NR) at the Pechora River mouth (68,5°N, 53,5°E). The basic data for these 2 points were back trajectories of air mass transport calculated for every day of January, April, July, and October during 10 years from 2001 to 2010. We used NCEP/NCAR Reanalysis Data Files with HYSPLIT 4 model and two approaches for analyzing the trajectories. The main source-regions were chosen for each reserve. The annual source emissions for the last decade are generalized from the data published by Roshydromet of Russia (http://www.nii-atmosphere.ru/files/PUBL/Eg_2008.doc). The deposition velocity was a sum of dry and wet components. The equal values of deposition velocities onto the surface were assumed for all impurities because they are mainly on submicron aerosol particles under atmospheric transport for a long distance. The seasonal and spatial variations of averaged deposition velocity were accounted in accordance with surface properties and precipitation regimes. As a result, the maximal air concentrations of aerosol pollutants are observed in cold seasons, whereas the maximal fluxes onto the surface occur in warm period. Thus, it's possible that the cleanest air does not indicate the same surface. Fe and Al are the crust (dust or soil) elements. Thus, their main

  3. Trees and Streets as Drivers of Urban Stormwater Nutrient Pollution.

    Science.gov (United States)

    Janke, Benjamin D; Finlay, Jacques C; Hobbie, Sarah E

    2017-09-05

    Expansion of tree cover is a major management goal in cities because of the substantial benefits provided to people, and potentially to water quality through reduction of stormwater volume by interception. However, few studies have addressed the full range of potential impacts of trees on urban runoff, which includes deposition of nutrient-rich leaf litter onto streets connected to storm drains. We analyzed the influence of trees on stormwater nitrogen and phosphorus export across 19 urban watersheds in Minneapolis-St. Paul, MN, U.S.A., and at the scale of individual streets within one residential watershed. Stormwater nutrient concentrations were highly variable across watersheds and strongly related to tree canopy over streets, especially for phosphorus. Stormwater nutrient loads were primarily related to road density, the dominant control over runoff volume. Street canopy exerted opposing effects on loading, where elevated nutrient concentrations from trees near roads outweighed the weak influence of trees on runoff reduction. These results demonstrate that vegetation near streets contributes substantially to stormwater nutrient pollution, and therefore to eutrophication of urban surface waters. Urban landscape design and management that account for trees as nutrient pollution sources could improve water quality outcomes, while allowing cities to enjoy the myriad benefits of urban forests.

  4. Reproduction of mountain birch along a strong pollution gradient near Monchegorsk, Northwestern Russia

    International Nuclear Information System (INIS)

    Kozlov, Mikhail V.; Zvereva, Elena L.

    2004-01-01

    We explored effects of severe pollution on sexual reproduction of mountain birch, Betula pubescens subsp. czerepanovii, by counting catkins on sample branches and weighing both somatic and generative structures of both short and long shoots from birches growing at 21 sites around large nickel-copper smelter at Monchegorsk, Northwestern Russia. Proportion of reproducing trees, production of catkins, shoot and catkin weight, as well as the relative difference in weight of somatic structures of generative and vegetative shoots, were generally independent of pollution load; in 2003 birches growing in industrial barrens produced more catkins than birches growing in unpolluted forests. Thus, we found no support for the hypothesis that reproductive allocation should decrease with decrease in environmental capacity. Absence of adverse effects might indicate that long-lasting pollution impact already eliminated the most sensitive individuals from the affected birch populations. - Capsule: Variation in reproductive characteristics of mountain birch near the nickel-copper smelter at Monchegorsk is independent of pollution load

  5. A carbon risk prediction model for Chinese heavy-polluting industrial enterprises based on support vector machine

    International Nuclear Information System (INIS)

    Zhou, Zhifang; Xiao, Tian; Chen, Xiaohong; Wang, Chang

    2016-01-01

    Chinese heavy-polluting industrial enterprises, especially petrochemical or chemical industry, labeled low carbon efficiency and high emission load, are facing the tremendous pressure of emission reduction under the background of global shortage of energy supply and constrain of carbon emission. However, due to the limited amount of theoretic and practical research in this field, problems like lacking prediction indicators or models, and the quantified standard of carbon risk remain unsolved. In this paper, the connotation of carbon risk and an assessment index system for Chinese heavy-polluting industrial enterprises (eg. coal enterprise, petrochemical enterprises, chemical enterprises et al.) based on support vector machine are presented. By using several heavy-polluting industrial enterprises’ related data, SVM model is trained to predict the carbon risk level of a specific enterprise, which allows the enterprise to identify and manage its carbon risks. The result shows that this method can predict enterprise’s carbon risk level in an efficient, accurate way with high practical application and generalization value.

  6. Pipe connection for high pressure and temperature loads

    International Nuclear Information System (INIS)

    Haferkamp, D.; Hodzic, A.; Paetz, E.; Stach, H.

    1976-01-01

    The patent proposes an inprovement of the clamping device for a pipe joint connecting pipelines which are subject to high pressure and temperature loads, e.g. in a nuclear power plant. This clamping device may be tightened and loosened by remote control. The proposed clamping ring consists of several segments connected with each other by hinge-type guide pins and fishplates. (UWI) [de

  7. Chronic high Epstein-Barr viral load state and risk for late-onset posttransplant lymphoproliferative disease/lymphoma in children.

    Science.gov (United States)

    Bingler, M A; Feingold, B; Miller, S A; Quivers, E; Michaels, M G; Green, M; Wadowsky, R M; Rowe, D T; Webber, S A

    2008-02-01

    Increased use of serial EBV-PCR monitoring after pediatric transplantation has led to the identification of asymptomatic patients who carry very high viral loads over prolonged periods. The significance of this high-load state is unknown. We speculated that this state may identify patients at high risk for development of late PTLD/lymphoma. We reviewed data on 71 pediatric heart recipients who had serial viral load monitoring since 1997. Chronic high-load state was defined as the presence of >16,000 genome copies/mL whole blood on > or =50% of samples over at least 6 months. Among 20 high-load carriers (eight following prior PTLD, seven with prior symptomatic EBV infection, five without previous EBV disease), 9 (45%) developed late-onset PTLD 2.5-8.4 years posttransplant (including with four Burkitt's lymphoma). Among 51 controls with low (n = 39) or absent (n = 12) loads, only 2 (4%; p < 0.001 absent/low vs. high load) developed late PTLD/lymphoma. By multivariable analysis, high-load carrier state (OR = 12.4, 95% CI 2.1-74.4) and prior history of PTLD (OR = 10.7, 95% CI 1.9-60.6) independently predicted late PTLD. A chronic high EBV-load state is not benign and is a predictor of de novo or recurrent PTLD.

  8. Load theory behind the wheel; perceptual and cognitive load effects.

    Science.gov (United States)

    Murphy, Gillian; Greene, Ciara M

    2017-09-01

    Perceptual Load Theory has been proposed as a resolution to the longstanding early versus late selection debate in cognitive psychology. There is much evidence in support of Load Theory but very few applied studies, despite the potential for the model to shed light on everyday attention and distraction. Using a driving simulator, the effect of perceptual and cognitive load on drivers' visual search was assessed. The findings were largely in line with Load Theory, with reduced distractor processing under high perceptual load, but increased distractor processing under high cognitive load. The effect of load on driving behaviour was also analysed, with significant differences in driving behaviour under perceptual and cognitive load. In addition, the effect of perceptual load on drivers' levels of awareness was investigated. High perceptual load significantly increased inattentional blindness and deafness, for stimuli that were both relevant and irrelevant to driving. High perceptual load also increased RTs to hazards. The current study helps to advance Load Theory by illustrating its usefulness outside of traditional paradigms. There are also applied implications for driver safety and roadway design, as the current study suggests that perceptual and cognitive load are important factors in driver attention. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  9. Environmental Monitoring, Water Quality - Total Maximum Daily Load (TMDL)

    Data.gov (United States)

    NSGIC Education | GIS Inventory — The Clean Water Act Section 303(d) establishes the Total Maximum Daily Load (TMDL) program. The purpose of the TMDL program is to identify sources of pollution and...

  10. Highly loaded behavior of kinesins increases the robustness of transport under high resisting loads.

    Directory of Open Access Journals (Sweden)

    Woochul Nam

    2015-03-01

    Full Text Available Kinesins are nano-sized biological motors which walk by repeating a mechanochemical cycle. A single kinesin molecule is able to transport its cargo about 1 μm in the absence of external loads. However, kinesins perform much longer range transport in cells by working collectively. This long range of transport by a team of kinesins is surprising because the motion of the cargo in cells can be hindered by other particles. To reveal how the kinesins are able to accomplish their tasks of transport in harsh intracellular circumstances, stochastic studies on the kinesin motion are performed by considering the binding and unbinding of kinesins to microtubules and their dependence on the force acting on kinesin molecules. The unbinding probabilities corresponding to each mechanochemical state of kinesin are modeled. The statistical characterization of the instants and locations of binding are captured by computing the probability of unbound kinesin being at given locations. It is predicted that a group of kinesins has a more efficient transport than a single kinesin from the perspective of velocity and run length. Particularly, when large loads are applied, the leading kinesin remains bound to the microtubule for long time which increases the chances of the other kinesins to bind to the microtubule. To predict effects of this behavior of the leading kinesin under large loads on the collective transport, the motion of the cargo is studied when the cargo confronts obstacles. The result suggests that the behavior of kinesins under large loads prevents the early termination of the transport which can be caused by the interference with the static or moving obstacles.

  11. Better target detection in the presence of collinear flankers under high working memory load

    Directory of Open Access Journals (Sweden)

    Jan W. De Fockert

    2014-10-01

    Full Text Available There are multiple ways in which working memory can influence selective attention. Aside from the content-specific effects of working memory on selective attention, whereby attention is more likely to be directed towards information that matches the contents of working memory, the mere level of load on working memory has also been shown to have an effect on selective attention. Specifically, high load on working memory is associated with increased processing of irrelevant information. In most demonstrations of the effect to-date, this has led to impaired target performance, leaving open the possibility that the effect partly reflects an increase in general task difficulty under high load. Here we show that working memory load can result in a performance gain when processing of distracting information aids target performance. The facilitation in the detection of a low-contrast Gabor stimulus in the presence of collinear flanking Gabors was greater when load on a concurrent working memory task was high, compared to low. This finding suggests that working memory can interact with selective attention at an early stage in visual processing.

  12. On-board emission measurement of high-loaded light-duty vehicles in Algeria.

    Science.gov (United States)

    Boughedaoui, Ménouèr; Kerbachi, Rabah; Joumard, Robert

    2008-01-01

    A sample of eight private gasoline and diesel conventional light-duty vehicles (LDVs) in use with various ages, carrying a load of 460 kg, were tested on a representative trip in the traffic flow of the city of Blida to obtain emission factors representing the actual use conditions of Algerian LDVs. The gas sampling system (mini-constant volume sampling) as well as the analyzers are carried on-board the vehicle. Around 55 tests were conducted during 3 months covering more than 480 km under various real driving conditions. The mean speed downtown is about 16.1 km/hr with a rather low acceleration, an average of 0.60 m/sec2. For each test, kinematics are recorded as well as the analysis of the four emitted pollutants carbon dioxide, carbon monoxide, oxides of nitrogen, and total hydrocarbons. Emission factors were evaluated according to speed for each category of gasoline and diesel engines. The influence of some parameters such as cold/hot start, age of vehicle and its state of maintenance are discussed. Results are compared with the European database ARTEMIS for comparable vehicles. These measurements contribute to the development of unit emission of the vehicles used in Algeria, which are necessary for the calculation of emission inventory of pollutants and greenhouse gases from the road transportation sector. The unit emissions constitute a tool of decisionmaking aid regarding the conception of new regulations of vehicle control and inspection in Algeria and even in similar developing countries.

  13. Tropospheric Emissions: Monitoring of Pollution Overview

    Science.gov (United States)

    Chance, Kelly; Liu, Xiong; Suleiman, Raid M.; Flittner, David; Al-Saadi, Jay; Janz, Scott

    2015-01-01

    TEMPO is now well into its implementation phase, having passed both its Key Decision Point C and the Critical Design Review (CDR) for the instrument. The CDR for the ground systems will occur in March 2016 and the CDR for the Mission component at a later date, after the host spacecraft has been selected. TEMPO is on schedule to measure atmospheric pollution for greater North America from space using ultraviolet and visible spectroscopy. TEMPO measures from Mexico City to the Canadian oil sands, and from the Atlantic to the Pacific, hourly and at high spatial resolution. TEMPO provides a tropospheric measurement suite that includes the key elements of tropospheric air pollution chemistry. Measurements are from geostationary (GEO) orbit, to capture the inherent high variability in the diurnal cycle of emissions and chemistry. The small product spatial footprint resolves pollution sources at sub-urban scale. Together, this temporal and spatial resolution improves emission inventories, monitors population exposure, and enables effective emission-control strategies. TEMPO takes advantage of a GEO host spacecraft to provide a modest cost mission that measures the spectra required to retrieve O3, NO2, SO2, H2CO, C2H2O2, H2O, aerosols, cloud parameters, and UVB radiation. TEMPO thus measures the major elements, directly or by proxy, in the tropospheric O3 chemistry cycle. Multi-spectral observations provide sensitivity to O3 in the lowermost troposphere, substantially reducing uncertainty in air quality predictions by 50 percent. TEMPO quantifies and tracks the evolution of aerosol loading. It provides near-real-time air quality products that will be made widely, publicly available. TEMPO provides much of the atmospheric measurement capability recommended for GEO-CAPE in the 2007 National Research Council Decadal Survey, Earth Science and Applications from Space: National Imperatives for the Next Decade and Beyond. Instruments from Europe (Sentinel 4) and Asia (GEMS) will

  14. Sewer infiltration/inflow: long-term monitoring based on diurnal variation of pollutant mass flux.

    Science.gov (United States)

    Bares, V; Stránský, D; Sýkora, P

    2009-01-01

    The paper deals with a method for quantification of infiltrating groundwater based on the variation of diurnal pollutant load and continuous water quality and quantity monitoring. Although the method gives us the potential to separate particular components of wastewater hygrograph, several aspects of the method should be discussed. Therefore, the paper investigates the cost-effectiveness, the relevance of pollutant load from surface waters (groundwater) and the influence of measurement time step. These aspects were studied in an experimental catchment of Prague sewer system, Czech Republic, within a three-month period. The results indicate high contribution of parasitic waters on night minimal discharge. Taking into account the uncertainty of the results and time-consuming maintenance of the sensor, the principal advantages of the method are evaluated. The study introduces a promising potential of the discussed measuring concept for quantification of groundwater infiltrating into the sewer system. It is shown that the conventional approach is sufficient and cost-effective even in those catchments, where significant contribution of foul sewage in night minima would have been assumed.

  15. High blood levels of persistent organic pollutants are statistically correlated with smoking

    DEFF Research Database (Denmark)

    Deutch, Bente; Hansen, Jens C.

    1999-01-01

    , smoking and intake of traditional Inuit food. Multiple linear regression analyses showed highly significant positive associations between the mothers' smoking status (never, previous, present) and plasma concentrations of all the studied organic pollutants both in maternal blood and umbilical cord blood...

  16. Modelling an environmental pollutant transport from the stacks to and through the soil

    Directory of Open Access Journals (Sweden)

    Rushdi M.M. El-Kilani

    2010-07-01

    Full Text Available In this paper, a model is presented for predicting the transport of an environmental pollutant from the source to and through the soil. The model can predict the deposition of an environmental pollutant on the soil surface due to the pollutant being loaded on dust particles, which are later deposited on the soil surface. The model is a coupling of three models: a model for predicting the cumulative dust deposition from near and far field sources on a certain area; a canopy microclimate model for solving the energy partition within the canopy elements and so predicting the water convection stream for pollutant transport through the soil; and coupling the deposition of these pollutants on the soil surface to a model for its transport through the soil. The air pollution model uses the Gaussian model approach, superimposed for multiple emission sources, to elucidate the deposition of pollutant laden airborne particulates on the soil surface. A complete canopy layer model is used to calculate within the canopy energy fluxes. The retardation factor for the pollutant is calculated from an adsorption batch experiment. The model was used to predict the deposition of lead laden dust particles on the soil surface and lead's transport through the soil layers inside a metropolitan region for: (1 three large cement factories and (2 a large number of smelters. The results show that, due to the very high retardation values for lead movement through the soil, i.e. ranging from 4371 to 53,793 from previous data and 234 from the adsorption experiment in this paper, lead is immobile and all the lead added to the soil surface via deposited dust or otherwise, even if it is totally soluble, will remain mostly on the soil surface and not move downwards due to high affinity with the soil.

  17. Air Pollutants Minimalization of Pollutant Absorber with Condensation System

    International Nuclear Information System (INIS)

    Ruhiat, Yayat; Wibowo, Firmanul Catur; Oktarisa, Yuvita

    2017-01-01

    Industrial development has implications for pollution, one of it is air pollution. The amount of air pollutants emitted from industrial depend on several factors which are capacity of its fuel, high chimneys and atmospheric stability. To minimize pollutants emitted from industries is created a tool called Pollutant Absorber (PA) with a condensing system. Research and Development with the approach of Design for Production was used as methodology in making PA. To test the function of PA, the simulation had been done by using the data on industrial emissions Cilegon industrial area. The simulation results in 15 years period showed that the PA was able to minimize the pollutant emissions of SO2 by 38% NOx by 37% and dust by 64%. Differences in the absorption of pollutants shows the weakness of particle separation process in the separator. This condition happen because the condensation process is less optimal during the absorption and separation in the separator. (paper)

  18. Evaluation of high temperature gas reactor for demanding cogeneration load follow

    International Nuclear Information System (INIS)

    Yan, Xing L.; Sato, Hiroyuki; Tachibana, Yukio; Kunitomi, Kazuhiko; Hino, Ryutaro

    2012-01-01

    Modular nuclear reactor systems are being developed around the world for new missions among which is cogeneration for industries and remote areas. Like existing fossil energy counterpart in these markets, a nuclear plant would need to demonstrate the feasibility of load follow including (1) the reliability to generate power and heat simultaneously and alone and (2) the flexibility to vary cogeneration rates concurrent to demand changes. This article reports the results of JAEA's evaluation on the high temperature gas reactor (HTGR) to perform these duties. The evaluation results in a plant design based on the materials and design codes developed with JAEA's operating test reactor and from additional equipment validation programs. The 600 MWt-HTGR plant generates electricity efficiently by gas turbine and 900degC heat by a topping heater. The heater couples via a heat transport loop to industrial facility that consumes the high temperature heat to yield heat product such as hydrogen fuel, steel, or chemical. Original control methods are proposed to automate transition between the load duties. Equipment challenges are addressed for severe operation conditions. Performance limits of cogeneration load following are quantified from the plant system simulation to a range of bounding events including a loss of either load and a rapid peaking of electricity. (author)

  19. Phosphorus Loadings to the World's Largest Lakes: Sources and Trends

    Science.gov (United States)

    Fink, Gabriel; Alcamo, Joseph; Flörke, Martina; Reder, Klara

    2018-04-01

    Eutrophication is a major water quality issue in lakes worldwide and is principally caused by the loadings of phosphorus from catchment areas. It follows that to develop strategies to mitigate eutrophication, we must have a good understanding of the amount, sources, and trends of phosphorus pollution. This paper provides the first consistent and harmonious estimates of current phosphorus loadings to the world's largest 100 lakes, along with the sources of these loadings and their trends. These estimates provide a perspective on the extent of lake eutrophication worldwide, as well as potential input to the evaluation and management of eutrophication in these lakes. We take a modeling approach and apply the WorldQual model for these estimates. The advantage of this approach is that it allows us to fill in large gaps in observational data. From the analysis, we find that about 66 of the 100 lakes are located in developing countries and their catchments have a much larger average phosphorus yield than the lake catchments in developed countries (11.1 versus 0.7 kg TP km-2 year-1). Second, the main source of phosphorus to the examined lakes is inorganic fertilizer (47% of total). Third, between 2005-2010 and 1990-1994, phosphorus pollution increased at 50 out of 100 lakes. Sixty percent of lakes with increasing pollution are in developing countries. P pollution changed primarily due to changing P fertilizer use. In conclusion, we show that the risk of P-stimulated eutrophication is higher in developing countries.

  20. Equitable fund allocation, an economical approach for sustainable waste load allocation.

    Science.gov (United States)

    Ashtiani, Elham Feizi; Niksokhan, Mohammad Hossein; Jamshidi, Shervin

    2015-08-01

    This research aims to study a novel approach for waste load allocation (WLA) to meet environmental, economical, and equity objectives, simultaneously. For this purpose, based on a simulation-optimization model developed for Haraz River in north of Iran, the waste loads are allocated according to discharge permit market. The non-dominated solutions are initially achieved through multiobjective particle swarm optimization (MOPSO). Here, the violation of environmental standards based on dissolved oxygen (DO) versus biochemical oxidation demand (BOD) removal costs is minimized to find economical total maximum daily loads (TMDLs). This can save 41% in total abatement costs in comparison with the conventional command and control policy. The BOD discharge permit market then increases the revenues to 45%. This framework ensures that the environmental limits are fulfilled but the inequity index is rather high (about 4.65). For instance, the discharge permit buyer may not be satisfied about the equity of WLA. Consequently, it is recommended that a third party or institution should be in charge of reallocating the funds. It means that the polluters which gain benefits by unfair discharges should pay taxes (or funds) to compensate the losses of other polluters. This intends to reduce the costs below the required values of the lowest inequity index condition. These compensations of equitable fund allocation (EFA) may help to reduce the dissatisfactions and develop WLA policies. It is concluded that EFA in integration with water quality trading (WQT) is a promising approach to meet the objectives.

  1. Effect of loading types on performance characteristics of a trickle-bed bioreactor and biofilter during styrene/acetone vapor biofiltration.

    Science.gov (United States)

    Halecky, Martin; Paca, Jan; Kozliak, Evguenii; Jones, Kim

    2016-07-02

    A 2:1 (w/w) mixture of styrene (STY) and acetone (AC) was subjected to lab-scale biofiltration under varied loading in both a trickle bed reactor (TBR) and biofilter (BF) to investigate substrate interactions and determine the limits of biofiltration efficiency of typical binary air pollutant mixtures containing both hydrophobic and polar components. A comparison of the STY/AC mixture degradation in the TBR and BF revealed higher pollutant removal efficiencies and degradation rates in the TBR, with the pollutant concentrations increasing up to the overloading limit. The maximum styrene degradation rates were 12 and 8 gc m(-3) h(-1) for the TBR and BF, respectively. However, the order of performance switched in favor of the BF when the loading was conducted by increasing air flow rate while keeping the inlet styrene concentration (Cin) constant in contrast to loading by increasing Cin. This switch may be due to a drastic difference in the effective surface area between these two reactors, so the biofilter becomes the reactor of choice when the rate-limiting step switches from biochemical processes to mass transfer by changing the loading mode. The presence of acetone in the mixture decreased the efficiency of styrene degradation and its degradation rate at high loadings. When the overloading was lifted by lowering the pollutant inlet concentrations, short-term back-stripping of both substrates in both reactors into the outlet air was observed, with a subsequent gradual recovery taking several hours and days in the BF and TBR, respectively. Removal of excess biomass from the TBR significantly improved the reactor performance. Identification of the cultivable strains, which was performed on Day 763 of continuous operation, showed the presence of 7 G(-) bacteria, 2 G(+) bacteria and 4 fungi. Flies and larvae of Lycoriella nigripes survived half a year of the biofilter operation by feeding on the biofilm resulting in the maintenance of a nearly constant pressure drop.

  2. The simulation research of dissolved nitrogen and phosphorus non-point source pollution in Xiao-Jiang watershed of Three Gorges Reservoir area.

    Science.gov (United States)

    Wu, Lei; Long, Tian-Yu; Li, Chong-Ming

    2010-01-01

    Xiao-jiang, with a basin area of almost 5,276 km(2) and a length of 182.4 km, is located in the center of the Three Gorges Reservoir Area, and is the largest tributary of the central section in Three Gorges Reservoir Area, farmland accounts for a large proportion of Xiao-jiang watershed, and the hilly cropland of purple soil is much of the farmland of the watershed. After the second phase of water storage in the Three Gorges Reservoir, the majority of sub-rivers in the reservoir area experienced eutrophication phenomenon frequently, and non-point source (NPS) pollution has become an important source of pollution in Xiao-jiang Watershed. Because dissolved nitrogen and phosphorus non-point source pollution are related to surface runoff and interflow, using climatic, topographic and land cover data from the internet and research institutes, the Semi-Distributed Land-use Runoff Process (SLURP) hydrological model was introduced to simulate the complete hydrological cycle of the Xiao-jiang Watershed. Based on the SLURP distributed hydrological model, non-point source pollution annual output load models of land use and rural residents were respectively established. Therefore, using GIS technology, considering the losses of dissolved nitrogen and phosphorus in the course of transport, a dissolved non-point source pollution load dynamic model was established by the organic coupling of the SLURP hydrological model and land-use output model. Through the above dynamic model, the annual dissolved non-point source nitrogen and phosphorus pollution output as well as the load in different types were simulated and quantitatively estimated from 2001 to 2008, furthermore, the loads of Xiao-jiang Watershed were calculated and expressed by temporal and spatial distribution in the Three Gorges Reservoir Area. The simulation results show that: the temporal changes of dissolved nitrogen and phosphorus load in the watershed are close to the inter-annual changes of rainfall runoff, and the

  3. Water pollution control. High performances finishing processing; Lutte contre la pollution des eaux. Finitions a haute performance

    Energy Technology Data Exchange (ETDEWEB)

    Gilles, P.

    1999-04-01

    The sewage recovery or recycling is an efficient way to control the water resources conservation. This paper characterizes in a first part the residual pollutants of an effluent rejected in the natural medium. It deals then the recycling and the water recovery objectives to present the possible processing. The author emphasizes some modern high performances engineering as, granular material filtration, membrane filtration, osmosis, UV disinfection, flocculation activated carbon or chemical oxidation. (A.L.B.)

  4. Spatiotemporal patterns and source attribution of nitrogen pollution in a typical headwater agricultural watershed in Southeastern China.

    Science.gov (United States)

    Chen, Wenjun; He, Bin; Nover, Daniel; Duan, Weili; Luo, Chuan; Zhao, Kaiyan; Chen, Wen

    2018-01-01

    Excessive nitrogen (N) discharge from agriculture causes widespread problems in aquatic ecosystems. Knowledge of spatiotemporal patterns and source attribution of N pollution is critical for nutrient management programs but is poorly studied in headwaters with various small water bodies and mini-point pollution sources. Taking a typical small watershed in the low mountains of Southeastern China as an example, N pollution and source attribution were studied for a multipond system around a village using the Hydrological Simulation Program-Fortran (HSPF) model. The results exhibited distinctive spatio-seasonal variations with an overall seriousness rank for the three indicators: total nitrogen (TN) > nitrate/nitrite nitrogen (NO x - -N) > ammonia nitrogen (NH 3 -N), according to the Chinese Surface Water Quality Standard. TN pollution was severe for the entire watershed, while NO x - -N pollution was significant for ponds and ditches far from the village, and the NH 3 -N concentrations were acceptable except for the ponds near the village in summer. Although food and cash crop production accounted for the largest source of N loads, we discovered that mini-point pollution sources, including animal feeding operations, rural residential sewage, and waste, together contributed as high as 47% of the TN and NH 3 -N loads in ponds and ditches. So, apart from eco-fertilizer programs and concentrated animal feeding operations, the importance of environmental awareness building for resource management is highlighted for small farmers in headwater agricultural watersheds. As a first attempt to incorporate multipond systems into the process-based modeling of nonpoint source (NPS) pollution, this work can inform other hydro-environmental studies on scattered and small water bodies. The results are also useful to water quality improvement for entire river basins.

  5. DNA damage in buccal mucosa cells of pre-school children exposed to high levels of urban air pollutants.

    Directory of Open Access Journals (Sweden)

    Elisabetta Ceretti

    Full Text Available Air pollution has been recognized as a human carcinogen. Children living in urban areas are a high-risk group, because genetic damage occurring early in life is considered able to increase the risk of carcinogenesis in adulthood. This study aimed to investigate micronuclei (MN frequency, as a biomarker of DNA damage, in exfoliated buccal cells of pre-school children living in a town with high levels of air pollution. A sample of healthy 3-6-year-old children living in Brescia, Northern Italy, was investigated. A sample of the children's buccal mucosa cells was collected during the winter months in 2012 and 2013. DNA damage was investigated using the MN test. Children's exposure to urban air pollution was evaluated by means of a questionnaire filled in by their parents that included items on various possible sources of indoor and outdoor pollution, and the concentration of fine particulate matter (PM10, PM2.5 and NO2 in the 1-3 weeks preceding biological sample collection. 181 children (mean age ± SD: 4.3 ± 0.9 years were investigated. The mean ± SD MN frequency was 0.29 ± 0.13%. A weak, though statistically significant, association of MN with concentration of air pollutants (PM10, PM2.5 and NO2 was found, whereas no association was apparent between MN frequency and the indoor and outdoor exposure variables investigated via the questionnaire. This study showed a high MN frequency in children living in a town with heavy air pollution in winter, higher than usually found among children living in areas with low or medium-high levels of air pollution.

  6. Tropospheric emissions: Monitoring of pollution (TEMPO)

    Science.gov (United States)

    Zoogman, P.; Liu, X.; Suleiman, R. M.; Pennington, W. F.; Flittner, D. E.; Al-Saadi, J. A.; Hilton, B. B.; Nicks, D. K.; Newchurch, M. J.; Carr, J. L.; Janz, S. J.; Andraschko, M. R.; Arola, A.; Baker, B. D.; Canova, B. P.; Chan Miller, C.; Cohen, R. C.; Davis, J. E.; Dussault, M. E.; Edwards, D. P.; Fishman, J.; Ghulam, A.; González Abad, G.; Grutter, M.; Herman, J. R.; Houck, J.; Jacob, D. J.; Joiner, J.; Kerridge, B. J.; Kim, J.; Krotkov, N. A.; Lamsal, L.; Li, C.; Lindfors, A.; Martin, R. V.; McElroy, C. T.; McLinden, C.; Natraj, V.; Neil, D. O.; Nowlan, C. R.; O`Sullivan, E. J.; Palmer, P. I.; Pierce, R. B.; Pippin, M. R.; Saiz-Lopez, A.; Spurr, R. J. D.; Szykman, J. J.; Torres, O.; Veefkind, J. P.; Veihelmann, B.; Wang, H.; Wang, J.; Chance, K.

    2017-01-01

    TEMPO was selected in 2012 by NASA as the first Earth Venture Instrument, for launch between 2018 and 2021. It will measure atmospheric pollution for greater North America from space using ultraviolet and visible spectroscopy. TEMPO observes from Mexico City, Cuba, and the Bahamas to the Canadian oil sands, and from the Atlantic to the Pacific, hourly and at high spatial resolution ( 2.1 km N/S×4.4 km E/W at 36.5°N, 100°W). TEMPO provides a tropospheric measurement suite that includes the key elements of tropospheric air pollution chemistry, as well as contributing to carbon cycle knowledge. Measurements are made hourly from geostationary (GEO) orbit, to capture the high variability present in the diurnal cycle of emissions and chemistry that are unobservable from current low-Earth orbit (LEO) satellites that measure once per day. The small product spatial footprint resolves pollution sources at sub-urban scale. Together, this temporal and spatial resolution improves emission inventories, monitors population exposure, and enables effective emission-control strategies. TEMPO takes advantage of a commercial GEO host spacecraft to provide a modest cost mission that measures the spectra required to retrieve ozone (O3), nitrogen dioxide (NO2), sulfur dioxide (SO2), formaldehyde (H2CO), glyoxal (C2H2O2), bromine monoxide (BrO), IO (iodine monoxide), water vapor, aerosols, cloud parameters, ultraviolet radiation, and foliage properties. TEMPO thus measures the major elements, directly or by proxy, in the tropospheric O3 chemistry cycle. Multi-spectral observations provide sensitivity to O3 in the lowermost troposphere, substantially reducing uncertainty in air quality predictions. TEMPO quantifies and tracks the evolution of aerosol loading. It provides these near-real-time air quality products that will be made publicly available. TEMPO will launch at a prime time to be the North American component of the global geostationary constellation of pollution monitoring

  7. Beyond PM2.5: The role of ultrafine particles on adverse health effects of air pollution.

    Science.gov (United States)

    Chen, Rui; Hu, Bin; Liu, Ying; Xu, Jianxun; Yang, Guosheng; Xu, Diandou; Chen, Chunying

    2016-12-01

    Air pollution constitutes the major threat to human health, whereas their adverse impacts and underlying mechanisms of different particular matters are not clearly defined. Ultrafine particles (UFPs) are high related to the anthropogenic emission sources, i.e. combustion engines and power plants. Their composition, source, typical characters, oxidative effects, potential exposure routes and health risks were thoroughly reviewed. UFPs play a major role in adverse impacts on human health and require further investigations in future toxicological research of air pollution. Unlike PM2.5, UFPs may have much more impacts on human health considering loads of evidences emerging from particulate matters and nanotoxicology research fields. The knowledge of nanotoxicology contributes to the understanding of toxicity mechanisms of airborne UFPs in air pollution. This article is part of a Special Issue entitled Air Pollution, edited by Wenjun Ding, Andrew J. Ghio and Weidong Wu. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Residential Air Pollution, Road Traffic, Greenness and Maternal Hypertension: Results from GINIplus and LISAplus.

    Science.gov (United States)

    Jendrossek, Mario; Standl, Marie; Koletzko, Sibylle; Lehmann, Irina; Bauer, Carl-Peter; Schikowski, Tamara; von Berg, Andrea; Berdel, Dietrich; Heinrich, Joachim; Markevych, Iana

    2017-07-01

    The public health burden of hypertension is high, but its relationship with long-term residential air pollution, road traffic, and greenness remains unclear. To investigate associations between residential air pollution, traffic, greenness, and hypertension among mothers. Information on doctor-diagnosed maternal hypertension was collected at the 15-year follow-up of two large population-based multicenter German birth cohorts-GINIplus and LISAplus (n=3063). Residential air pollution was modelled by land use regression models within the ESCAPE and universal kriging within the APMoSPHERE projects. Road traffic was defined as traffic load on major roads within a 100-m buffer around residences. Vegetation level ( ie , greenness) was defined as the mean Normalized Difference Vegetation Index in a 500-m buffer around residences and was assessed from Landsat 5 TM satellite images. All the exposure variables were averaged over three residential addresses during the last 10 years and categorized into tertiles or dichotomized. The individual associations between each of the exposure variables and hypertension were assessed using logistic regression analysis. No significant and consistent associations across different levels of adjustment were observed between the exposures of interest and hypertension. The only significant estimate was found with coarse particulate matter concentrations (OR 1.66, 95% CI 1.01 to 2.74; 3 rd vs 1 st tertile) among mothers residing in the Wesel area. No significant associations were observed with traffic load or greenness. This study does not provide evidence on detrimental effects of air pollution and road traffic or beneficial effects of greenness on hypertension among German adults.

  9. Metal pollution assessment in the surface sediment of Lake Nasser, Egypt

    Directory of Open Access Journals (Sweden)

    Mohamed E. Goher

    2014-01-01

    Full Text Available Eight heavy metals were measured seasonally in the sediment of Lake Nasser during 2013. 27 sites were chosen through 9 sectors across the main channel of the lake from Abu-Simbel to Aswan High Dam to assess the levels of the selected metals. The abundance of these metals was in the order of Fe > Mn > Zn > Cr > Ni > Cu > Pb > Cd, with mean concentrations of 12.41 mg/g, 279.56, 35.38, 30.79, 27.56, 21.78, 11.21 and 0.183 μg/g, respectively. Heavy metals are positively correlated with fine particles (mud fractions and organic matter accumulation. The results showed perspicuous spatial high significant differences (P < 0.01 for all the measured metals. Fe, Cr, Ni, Pb and Cd exhibited temporally high significant differences (P < 0.01 before and after the flood period. Four Pollution Indices were used for the environmental assessment of Lake Nasser sediment. The indices included three single indices, Enrichment Factor (EF, Index of Geo-accumulation (Igeo and Contamination Factor (CF. While the fourth, Pollution Load Index (PLI was an integrated index. The pollution indexes confirmed that the Lake Nasser sediment was not contaminated with these elements. Sediments of Lake Nasser may be represented as a reference for the pre-industrial background of River Nile Sediments downstream Aswan High Dam.

  10. Surveillance of microbial indicators and physicochemical parameters to investigate pollution status of Lahore canal

    International Nuclear Information System (INIS)

    Tahir, A.; Kanwal, F.; Mateen, B.

    2011-01-01

    The Lahore canal is an important watershed in Lahore. The present study was conducted to monitor pollution load of Lahore canal. Surface water was collected from the middle of the canal at four different sites, and analysed for physicochemical parameters (temperature, pH, EC, DO, BOD/sub 5/, turbidity, nitrates, phosphates) and microbial load (bacteria (TVC), total coliform and fungi). Water quality parameters were monitored from May to August at four sites along 17Km long patch. Surface water was collected in the middle of the canal. The results were compared with IWQ guidelines proposed by WWF, Pakistan. Pollution load of Lahore Canal revealed an alarming situation. Water can be used for the irrigation purpose, but only with advanced treatment. (author)

  11. Integrated modelling of Priority Pollutants in stormwater systems

    DEFF Research Database (Denmark)

    Vezzaro, Luca; Ledin, Anna; Mikkelsen, Peter Steen

    2012-01-01

    The increasing focus on urban diffuse sources of Priority Pollutants (PPs) has highlighted stormwater as an important contributor to contamination of natural water bodies. This study presents an example of an integrated model developed to be able to quantify PP loads discharged by stormwater...

  12. Air quality in a simulated office environment as a result of reducing pollution sources and increasing ventilation

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Bako-Biro, Zsolt; Clausen, Geo

    2002-01-01

    Air quality was studied in an office space classified as low-polluting and ventilated with outdoor air at a rate of 1 h-1. The pollution load in the space was changed by introducing or removing common building-related indoor pollution sources (linoleum, sealant and wooden shelves with books and p...

  13. Polybiguanide (PHMB) loaded in PLA scaffolds displaying high hydrophobic, biocompatibility and antibacterial properties

    Energy Technology Data Exchange (ETDEWEB)

    Llorens, Elena; Calderón, Silvia [Departament d' Enginyeria Química, Universitat Politècnica de Catalunya, Av. Diagonal 647, Barcelona E-08028 (Spain); Valle, Luis J. del, E-mail: luis.javier.del.valle@upc.edu [Departament d' Enginyeria Química, Universitat Politècnica de Catalunya, Av. Diagonal 647, Barcelona E-08028 (Spain); Puiggalí, Jordi [Departament d' Enginyeria Química, Universitat Politècnica de Catalunya, Av. Diagonal 647, Barcelona E-08028 (Spain); Center for Research in Nano-Engineering (CrNE), Universitat Politècnica de Catalunya, Edifici C, C/Pasqual i Vila s/n, Barcelona E-08028 (Spain)

    2015-05-01

    Polyhexamethylenebiguanide hydrochloride (PHMB), a low molecular weight polymer related to chlorohexidine (CHX), is a well-known antibacterial agent. In this study, polylactide (PLA) nanofibers loaded with PHMB were produced by electrospinning to obtain 3D biodegradable scaffolds with antibacterial properties. PLA fibers loaded with CHX were used as control. The electrospun fibers were studied and analyzed by SEM, FTIR, DSC and contact angle measurements. PHMB and CHX release from loaded scaffolds was evaluated, as well as their antibacterial activity and biocompatibility. The results showed that the nanofibers became smoother and their diameter smaller with increasing the amount of loaded PHMB. This feature led to an increase of both surface roughness and hydrophobicity of the scaffold. PHMB release was highly dependent on the hydrophilicity of the medium and differed from that determined for CHX. Lastly, PHMB-loaded PLA scaffolds showed antibacterial properties since they inhibited adhesion and bacterial growth, and exhibited biocompatible characteristics for the adhesion and proliferation of both fibroblast and epithelial cell lines. - Highlights: • Nanofibers of PLA-PHMB (antibacterial polymer) were prepared by electrospinning. • PHMB has hydrophilic character but the PLA-PHMB scaffolds were highly hydrophobic. • The high-hydrophobicity of the new scaffolds conditioned the release of PHMB. • The controlled release of PHMB inhibited the growth and bacterial adhesion. • PLA-PHMB scaffolds have biocompatibility with fibroblast and epithelial cells.

  14. Polybiguanide (PHMB) loaded in PLA scaffolds displaying high hydrophobic, biocompatibility and antibacterial properties

    International Nuclear Information System (INIS)

    Llorens, Elena; Calderón, Silvia; Valle, Luis J. del; Puiggalí, Jordi

    2015-01-01

    Polyhexamethylenebiguanide hydrochloride (PHMB), a low molecular weight polymer related to chlorohexidine (CHX), is a well-known antibacterial agent. In this study, polylactide (PLA) nanofibers loaded with PHMB were produced by electrospinning to obtain 3D biodegradable scaffolds with antibacterial properties. PLA fibers loaded with CHX were used as control. The electrospun fibers were studied and analyzed by SEM, FTIR, DSC and contact angle measurements. PHMB and CHX release from loaded scaffolds was evaluated, as well as their antibacterial activity and biocompatibility. The results showed that the nanofibers became smoother and their diameter smaller with increasing the amount of loaded PHMB. This feature led to an increase of both surface roughness and hydrophobicity of the scaffold. PHMB release was highly dependent on the hydrophilicity of the medium and differed from that determined for CHX. Lastly, PHMB-loaded PLA scaffolds showed antibacterial properties since they inhibited adhesion and bacterial growth, and exhibited biocompatible characteristics for the adhesion and proliferation of both fibroblast and epithelial cell lines. - Highlights: • Nanofibers of PLA-PHMB (antibacterial polymer) were prepared by electrospinning. • PHMB has hydrophilic character but the PLA-PHMB scaffolds were highly hydrophobic. • The high-hydrophobicity of the new scaffolds conditioned the release of PHMB. • The controlled release of PHMB inhibited the growth and bacterial adhesion. • PLA-PHMB scaffolds have biocompatibility with fibroblast and epithelial cells

  15. Behavior of quenched and tempered steels under high strain rate compression loading

    International Nuclear Information System (INIS)

    Meyer, L.W.; Seifert, K.; Abdel-Malek, S.

    1997-01-01

    Two quenched and tempered steels were tested under compression loading at strain rates of ε = 2.10 2 s -1 and ε = 2.10 3 s -1 . By applying the thermal activation theory, the flow stress at very high strain rates of 10 5 to 10 6 s -1 is derived from low temperature and high strain rate tests. Dynamic true stress - true strain behaviour presents, that stress increases with increasing strain until a maximum, then it decreases. Because of the adiabatic process under dynamic loading the maximum flow stress will occur at a lower strain if the strain rate is increased. Considering strain rate, strain hardening, strain rate hardening and strain softening, a constitutive equation with different additive terms is successfully used to describe the behaviour of material under dynamic compression loading. Results are compared with other models of constitutive equations. (orig.)

  16. First Observations of SO2 from the Satellite Suomi NPP OMPS: Widespread Air Pollution Events Over China

    Science.gov (United States)

    Yang, Kai; Dickerson, Russell R.; Carn, Simon A.; Ge, Cui; Wang, Jun

    2013-01-01

    Severe smog episodes over China in January 2013 received worldwide attention. This air pollution was distinguished by heavy loadings of fine particulate matter and SO2. To characterize these episodes, we employed the Ozone Mapping and Profiler Suite, Nadir Mapper (OMPS NM), an ultraviolet (UV) spectrometer flying on the Suomi National Polar-orbiting Partnership (SNPP) spacecraft since October 2011. We developed an advanced algorithm to quantify SO2 in the lower troposphere and achieved high-quality retrievals from OMPS NM, which are characterized by high precision, approx. 0.2 Dobson Units (DU; 1 DU = 2.69 x 10(exp 16) molecules/sq cm) for instantaneous field of view SO2 data and low biases (within +/-0.2 DU). Here we report SO2 retrievals and UV aerosol index data for these pollution events. The SO2 columns and the areas covered by high pollutant concentrations are quantified; the results reveal for the first time the full extent (an area of approx. 10(exp 6) sq km containing up to 60 kt of SO2) of these episodes.

  17. Photolysis of aromatic pollutants in clean and dirty ice

    Science.gov (United States)

    Kahan, T.; Malley, P.; Stathis, A.

    2015-12-01

    Anthropogenic aromatic pollutants such as polycyclic aromatic hydrocarbons (PAHs) and substituted benzenes often become more toxic following atmospheric oxidation. Photolysis of these pollutants in ice can be much faster than that in aqueous solution, which might lead to higher carcinogenic loadings in snow-covered regions. In this work we investigate two things. First, we investigate whether toluene, which has been detected at very elevated concentrations near hydraulic fracturing operations, can undergo photolysis at ice surfaces. Toluene in aqueous solution does not absorb sunlight, so photolysis has not been considered a potential atmospheric fate. However, benzene was recently demonstrated to undergo a significant red shift in its absorbance at ice surfaces, leading to photolysis under environmentally-relevant conditions. Here we show that toluene also undergoes photolysis at ice surfaces. In a second set of experiments, we have investigated the effects of organic matter on the photolysis kinetics ofPAHs in ice and at ice surfaces. We found that very small loadings of hydrophobic organics such as octanol can significantly suppress PAH photolysis kinetics in ice, but that the primary effect of the more soluble fulvic acid is competitive photon absorption. Our results show that photochemistry of anthropogenic pollutants can follow very different mechanisms and kinetics in ice than in aqueous solution, and that the photochemical fate of these pollutants depends strongly on the composition of the snow. These results have implications for pollutant fate and human health in a wide range of snow-covered environments including remote areas, cities, and regions near gas and oil extraction operations.

  18. A highly energy-efficient flow-through electro-Fenton process for organic pollutants degradation

    International Nuclear Information System (INIS)

    Ma, Liang; Zhou, Minghua; Ren, Gengbo; Yang, Weilu; Liang, Liang

    2016-01-01

    Highlights: • A highly energy-efficient flow-through electro-Fenton reactor was designed. • It had high H 2 O 2 yield and low energy consumption for organic pollutants degradation. • The effect of operational parameters was optimized and possible process mechanism was studied. • The novel system performed wide practicability and potential for organic pollutants degradation. - Abstract: A highly energy-efficient flow-through Electro-Fenton (E-Fenton) reactor for oxidation of methylene blue (MB) from aqueous solution was designed using a perforated DSA as anode and the graphite felt modified by carbon black and polytetrafluoroethylene (PTFE) as cathode for the in situ generation of H 2 O 2 . The modified cathode had a high H 2 O 2 production with low energy consumption, which was characterized by scanning electron microscopy (SEM), nitrogen adsorption-desorption study and contact angle. The flow-through E-Fenton system was compared to the flow-by and regular one, and confirmed to be best on MB removal and TOC degradation. The operational parameters such as current density, pH, Fe 2+ concentration and flow rate were optimized. The MB and TOC removal efficiency of the effluents could keep above 90% and 50%, respectively, and the energy consumption was 23.0 kWh/kgTOC at the current density of 50 mA, pH 3, 0.3 mM Fe 2+ , and the flow rate of 7 mL/min. ·OH was proved to be the main oxidizing species in this system. After 5 times operation, the system, especially cathode, still showed good stability. Five more organic pollutants including orange II (OG), tartrazine, acetylsalicylic acid (ASA), tetracycline (TC) and 2,4-dichlorophen (2,4-DCP) were investigated and the electric energy consumption (EEC) was compared with literatures. All results demonstrated that this flow-through E-Fenton system was energy-efficient and potential for degradation of organic pollutants.

  19. Lichens as indicators for immission load in the urban region of Frankfurt/M

    Energy Technology Data Exchange (ETDEWEB)

    Kirschbaum, U; Klee, R; Steubing, L

    1971-01-01

    The plotting of a map showing the natural lichen growth on trees has been undertaken in Frankfurt, and, in addition, the degree of air pollution has also been tested by means of Parmelia physodes planted at different measuring points. The city center is characterized by a complete absence of lichen which shows that the air in this zone is very unhealthy. In contrast to this, the middle and outer pollution control zones are to be considered as a residential district offering better hygienic conditions. The limits of the zone completely devoid of lichen is characterized in Frankfurt by an average SO/sub 2/ load of 0.11 mg SO/sub 2//m/sup 3/, and by a high dust concentration. 20 references.

  20. CHEMICAL INTERACTIONS TO CLEANUP HIGHLY POLLUTED AUTOMOBILE SERVICE STATION WASTEWATER BY BIOADSORPTION-COAGULATION-FLOCCULATION

    Directory of Open Access Journals (Sweden)

    Carlos Banchon

    2017-01-01

    Full Text Available The present study addresses an ecofriendly solution to treat automobile service stations effluents with high concentrations of oily substances, surfactants, organic matter and heavy metals. Bioadsorption using sawdust from pine trees, sugar cane bagasse and coconut coir without any chemical modification removed colloidal contamination up to 70%. Polyaluminium chloride, ferric chloride and polyacrylamide were applied to remove dissolved and colloidal pollutants under saline conditions without change of initial pH. Both bioadsorption and coagulation-flocculation removed up to 97.8% of BOD, COD, surfactants and heavy metals at a saline concentration of 1.5% NaCl. The increase of ionic strength promoted a high sludge index and a representative cost saving in chemicals consumption of almost 70%. High levels of pollution removal with the minimal use of chemicals is herein presented.

  1. Factors controlling stream water nitrate and phosphor loads during precipitation events

    Science.gov (United States)

    Rozemeijer, J.; van der Velde, Y.; van Geer, F.; de Rooij, G. H.; Broers, H.; Bierkens, M. F.

    2009-12-01

    Pollution of surface waters in densely populated areas with intensive land use is a serious threat to their ecological, industrial and recreational utilization. European and national manure policies and several regional and local pilot projects aim at reducing pollution loads to surface waters. For the evaluation of measures, water authorities and environmental research institutes are putting a lot of effort into monitoring surface water quality. Within regional surface water quality monitoring networks, the measurement locations are usually situated in the downstream part of the catchment to represent a larger area. The monitoring frequency is usually low (e.g. monthly), due to the high costs for sampling and analysis. As a consequence, human induced trends in nutrient loads and concentrations in these monitoring data are often concealed by the large variability of surface water quality caused by meteorological variations. Because this natural variability in surface water quality is poorly understood, large uncertainties occur in the estimates of (trends in) nutrient loads or average concentrations. This study aims at uncertainty reduction in the estimates of mean concentrations and loads of N and P from regional monitoring data. For this purpose, we related continuous records of stream water N and P concentrations to easier and cheaper to collect quantitative data on precipitation, discharge, groundwater level and tube drain discharge. A specially designed multi scale experimental setup was installed in an agricultural lowland catchment in The Netherlands. At the catchment outlet, continuous measurements of water quality and discharge were performed from July 2007-January 2009. At an experimental field within the catchment we collected continuous measurements of precipitation, groundwater levels and tube drain discharges. 20 significant rainfall events with a variety of antecedent conditions, durations and intensities were selected for analysis. Singular and

  2. Impact of acute exposure to air pollution on the cardiorespiratory performance of military firemen

    Directory of Open Access Journals (Sweden)

    R.S. Oliveira

    2006-12-01

    Full Text Available The objective of the present study was to determine the impact of acute short-term exposure to air pollution on the cardiorespiratory performance of military fireman living and working in the city of Guarujá, São Paulo, Brazil. Twenty-five healthy non-smoking firemen aged 24 to 45 years had about 1 h of exposure to low and high levels of air pollution. The tests consisted of two phases: phase A, in Bertioga, a town with low levels of air pollution, and phase B, in Cubatão, a polluted town, with a 7-day interval between phases. The volunteers remained in the cities (Bertioga/Cubatão only for the time required to perform the tests. Cumulative load 10 ± 2 min-long exertion tests were performed on a treadmill, consisting of a 2-min stage at a load of 7 km/h, followed by increasing exertion of 1 km h-1 min-1 until the maximum individual limit. There were statistically significant differences (P < 0.05 in anaerobic threshold (AT between Cubatão (35.04 ± 4.91 mL kg-1 min-1 and Bertioga (36.98 ± 5.62 mL kg-1 min-1; P = 0.01, in the heart rate at AT (AT HR; Cubatão 152.08 ± 14.86 bpm, Bertioga 157.44 ± 13.64 bpm; P = 0.001, and in percent maximal oxygen consumption at AT (AT%VO2max; Cubatão 64.56 ± 6.55%, Bertioga 67.40 ± 5.35%; P = 0.03. However, there were no differences in VO2max, maximal heart rate or velocity at AT (ATvel observed in firemen between towns. The acute exposure to pollutants in Cubatão, SP, caused a significant reduction in the performance at submaximal levels of physical exertion.

  3. Changes in air pollution and children`s health in East Germany between 1991 and 1994

    Energy Technology Data Exchange (ETDEWEB)

    Kraemer, U.; Schlipkoeter, H.W.; Dolgner, R. [Medical Inst. of Environmental Hygiene, Duesseldorf (Germany); Willer, H.M. [State Inst. of Hygiene, Magdeburg (Germany)

    1995-12-31

    Already in the 1960s a lot of cross-sectional studies were conducted to determine the effects of air-pollution on respiratory diseases or symptoms of children. According to the then dominating type of air-pollution, effects of SO{sub 2} and TSP were mainly studied. Usually SO{sub 2} and TSP were highly correlated and their effects could not be separated satisfactorily. Such a high correlation was not seen when comparing annual mean concentrations in different towns of East and West Germany in 1989. The range of SO{sub 2} values was from 20 to 310 g/m{sup 3} whereas the range of TSP was narrower, from 65 to 123 {mu}g/m{sup 3} In 1991 therefore a study was started to compare the effects of different types and amounts of air pollution on children`s health. The results of the first cross-sectional study, in 1991, were presented at the 9{sup th} World Clean Air Congress. It was found that airway diseases and respiratory symptoms were clearly related to the SO{sub 2} pollution load. This was not true for allergic manifestations. Since 1990 there is a considerable reduction of SO{sub 2} pollution in East Germany. The aim of this presentation is to show that the associations which had been found on an spatial scale can be seen on an temporal scale, too. (author)

  4. Changes in air pollution and children`s health in East Germany between 1991 and 1994

    Energy Technology Data Exchange (ETDEWEB)

    Kraemer, U; Schlipkoeter, H W; Dolgner, R [Medical Inst. of Environmental Hygiene, Duesseldorf (Germany); Willer, H M [State Inst. of Hygiene, Magdeburg (Germany)

    1996-12-31

    Already in the 1960s a lot of cross-sectional studies were conducted to determine the effects of air-pollution on respiratory diseases or symptoms of children. According to the then dominating type of air-pollution, effects of SO{sub 2} and TSP were mainly studied. Usually SO{sub 2} and TSP were highly correlated and their effects could not be separated satisfactorily. Such a high correlation was not seen when comparing annual mean concentrations in different towns of East and West Germany in 1989. The range of SO{sub 2} values was from 20 to 310 g/m{sup 3} whereas the range of TSP was narrower, from 65 to 123 {mu}g/m{sup 3} In 1991 therefore a study was started to compare the effects of different types and amounts of air pollution on children`s health. The results of the first cross-sectional study, in 1991, were presented at the 9{sup th} World Clean Air Congress. It was found that airway diseases and respiratory symptoms were clearly related to the SO{sub 2} pollution load. This was not true for allergic manifestations. Since 1990 there is a considerable reduction of SO{sub 2} pollution in East Germany. The aim of this presentation is to show that the associations which had been found on an spatial scale can be seen on an temporal scale, too. (author)

  5. Using iron-loaded sepiolite obtained by adsorption as a catalyst in the electro-Fenton oxidation of Reactive Black 5.

    Science.gov (United States)

    Iglesias, O; Fernández de Dios, M A; Pazos, M; Sanromán, M A

    2013-09-01

    This study explores the possibility of using iron-loaded sepiolite, obtained by recovering iron from polluted water, as a catalyst in the electro-Fenton oxidation of organic pollutants in textile effluents. The removal of iron ions from aqueous solution by adsorption on sepiolite was studied in batch tests at iron concentrations between 100 and 1,000 ppm. Electro-Fenton experiments were carried out in an electrochemical cell with a working volume of 0.15 L, an air flow of 1 L/min, and 3 g of iron-loaded sepiolite. An electric field was applied using a boron-doped diamond anode and a graphite sheet cathode connected to a direct current power supply with a constant potential drop. Reactive Black 5 (100 mg/L) was selected as the model dye. The adsorption isotherms proved the ability of the used adsorbent. The removal of the iron ion by adsorption on sepiolite was in the range of 80-100 % for the studied concentration range. The Langmuir and Freundlich isotherms were found to be applicable in terms of the relatively high regression values. Iron-loaded sepiolite could be used as an effective heterogeneous catalyst for the degradation of organic dyes in the electro-Fenton process. Successive batch processes were performed at optimal working conditions (5 V and pH 2). The results indicate the suitability of the proposed combined process, adsorption to iron remediation followed by the application of the obtained iron-loaded sepiolite to the electro-Fenton technique, to oxidize polluted effluents.

  6. Implementation of Tropospheric Emissions: Monitoring of Pollution (TEMPO)

    Science.gov (United States)

    Chance, K.; Liu, X.; Suleiman, R. M.; Flittner, D. E.; Al-Saadi, J. A.; Janz, S. J.

    2014-12-01

    The updated status of TEMPO, as it proceeds from formulation phase into implementation phase is presented. TEMPO, the first NASA Earth Venture Instrument, will measure atmospheric pollution for greater North America from space using ultraviolet and visible spectroscopy. TEMPO measures from Mexico City to the Canadian oil sands, and from the Atlantic to the Pacific, hourly and at high spatial resolution. TEMPO provides a tropospheric measurement suite that includes the key elements of tropospheric air pollution chemistry. Measurements are from geostationary (GEO) orbit, to capture the inherent high variability in the diurnal cycle of emissions and chemistry. The small product spatial footprint resolves pollution sources at sub-urban scale. Together, this temporal and spatial resolution improves emission inventories, monitors population exposure, and enables effective emission-control strategies. TEMPO takes advantage of a GEO host spacecraft to provide a modest cost mission that measures the spectra required to retrieve O3, NO2, SO2, H2CO, C2H2O2, H2O, aerosols, cloud parameters, and UVB radiation. TEMPO thus measures the major elements, directly or by proxy, in the tropospheric O3 chemistry cycle. Multi-spectral observations provide sensitivity to O3 in the lowermost troposphere, reducing uncertainty in air quality predictions by 50%. TEMPO quantifies and tracks the evolution of aerosol loading. It provides near-real-time air quality products that will be made widely, publicly available. TEMPO provides much of the atmospheric measurement capability recommended for GEO-CAPE in the 2007 National Research Council Decadal Survey, Earth Science and Applications from Space: National Imperatives for the Next Decade and Beyond. GEO-CAPE is not planned for implementation this decade. However, instruments from Europe (Sentinel 4) and Asia (GEMS) will form parts of a global GEO constellation for pollution monitoring later this decade, with a major focus on intercontinental

  7. Effects of organic pollution on biological communities of marine biofilm on hard substrata

    International Nuclear Information System (INIS)

    Sanz-Lázaro, C.; Fodelianakis, S.; Guerrero-Meseguer, L.; Marín, A.; Karakassis, I.

    2015-01-01

    We examined the effect of organic enrichment on diatom and bacterial assemblages of marine epilithic biofilms on two locations in the Mediterranean, one situated in Spain and the other in Greece. Total organic carbon, total organic nitrogen, stable isotopes (δ 13 C and δ 15 N) and chlorophyll a indicated significant incorporation of organic wastes, increased primary production and trophic niche modifications on the biofilms close to the organic enrichment source. In Spain, where the organic load was higher than in Greece, diatom and, to some extent, bacterial assemblages varied following the organic enrichment gradient. The taxonomic richness of diatom and bacterial communities was not influenced by organic enrichment. Classical community parameters showed consistent patterns to organic pollution in both locations, whereas community assemblages were only influenced when organic pollution was greatest. The successional patterns of these communities were similar to other epilithic communities. The modification of community assemblages induced by organic pollution may affect ecological functions. - Highlights: • We examined the effect of organic enrichment on assemblages of marine biofilms. • Classical community parameters showed consistent patterns to organic pollution. • Diatom and bacterial assemblages were affected under high level of organic enrichment. • Successional patterns were similar to other communities inhabiting hard substrata. • Assemblage modifications induced by organic pollution may affect ecological functions. - Organic pollution modifies the assemblages of biofilm communities which may affect important ecological functions

  8. [Explore the spatial and temporal patterns of water pollution in the Yincungang canal of the Lake Taihu basin, China].

    Science.gov (United States)

    Yang, Xiao-Ying; Luo, Xing-Zhang; Zheng, Zheng; Fang, Shu-Bo

    2012-09-01

    Two high-density snap-shot samplings were conducted along the Yincungang canal, one important tributary of the Lake Tai, in April (low flow period) and June (high flow period) of 2010. Geostatistical analysis based on the river network distance was used to analyze the spatial and temporal patterns of the pollutant concentrations along the canal with an emphasis on chemical oxygen demand (COD) and total nitrogen (TN). Study results have indicated: (1) COD and TN concentrations display distinctly different spatial and temporal patterns between the low and high flow periods. COD concentration in June is lower than that in April, while TN concentration has the contrary trend. (2) COD load is relatively constant during the period between the two monitoring periods. The spatial correlation structure of COD is exponential for both April and June, and the change of COD concentration is mainly influenced by hydrological conditions. (3) Nitrogen load from agriculture increased significantly during the period between the two monitoring periods. Large amount of chaotic fertilizing by individual farmers has led to the loss of the spatial correlation among the observed TN concentrations. Hence, changes of TN concentration in June are under the dual influence of agricultural fertilizing and hydrological conditions. In the view of the complex hydrological conditions and serious water pollution in the Lake Taihu region, geostatistical analysis is potentially a useful tool for studying the characteristics of pollutant distribution and making predictions in the region.

  9. High-Resolution Gas Metering and Nonintrusive Appliance Load Monitoring System

    Science.gov (United States)

    Tewolde, Mahder

    This thesis deals with design and implementation of a high-resolution metering system for residential natural gas meters. Detailed experimental measurements are performed on the meter to characterize and understand its measurement properties. Results from these experiments are used to develop a simple, fast and accurate technique to non-intrusively monitor the gas consumption of individual appliances in homes by resolving small amounts of gas usage. The technique is applied on an existing meter retrofitted with a module that includes a high-resolution encoder to collect gas flow data and a microprocessor to analyze and identify appliance load profiles. This approach provides a number of appealing features including low cost, easy installation and integration with automated meter reading (AMR) systems. The application of this method to residential gas meters currently deployed is also given. This is done by performing a load simulation on realistic gas loads with the aim of identifying the necessary parameters that minimize the cost and complexity of the mechanical encoder module. The primary benefits of the system are efficiency analysis, appliance health monitoring and real-time customer feedback of gas usage. Additional benefits of include the ability to detect very small leaks and theft. This system has the potential for wide scale market adoption.

  10. Influence of loading distribution on the performance of high pressure turbine blades

    Science.gov (United States)

    Corriveau, Daniel

    Midspan measurements were made in a transonic wind tunnel for three High Pressure (HP) turbine blade cascades at both design and off-design incidences. Comparisons with two-dimensional numerical simulations of the cascade flow were also made. The baseline profile is the midspan section of a HP turbine blade of fairly recent design. It is considered mid-loaded. To gain a better understanding of blade loading limits and the influence of loading distributions, the profile of the baseline airfoil was modified to create two new airfoils having aft-loaded and front-loaded pressure distributions. Tests were performed for exit Mach numbers between 0.6 and 1.2. In addition, measurements were made for an extended range of Reynolds numbers for constant Mach numbers of 0.6, 0.85, 0.95 and 1.05. At the design exit Mach number of 1.05 and at design incidence, the aft-loaded airfoil showed a reduction of almost 20% in the total pressure losses compared with the baseline airfoil. Based on the analysis of wake traverse data and base pressure measurements combined with numerical results, it was found that the poorer loss performance of the baseline mid-loaded profile compared to the aft-loaded blade could be attributed to the former's higher rear suction side curvature, which resulted in higher flow velocity in that region, which, in turn, contributed to reducing the base pressure. The lower base pressure at the trailing edge resulted in a stronger trailing edge shock system for the mid-loaded blade. This shock system increased the losses for the mid-loaded baseline profile when compared to the aft-loaded profile. On the negative side, it was also found that as Mach numbers were increased beyond the design value the performance of the aft-loaded blade deteriorated rapidly. Under such conditions, the front-loaded airfoil showed generally inferior performance compared with the baseline airfoil. At off-design incidence, the aft-loaded blade maintained a superior loss performance over a

  11. Spatial assessment of animal manure spreading and groundwater nitrate pollution

    Directory of Open Access Journals (Sweden)

    Roberta Infascelli

    2009-11-01

    Full Text Available Nitrate concentration in groundwater has frequently been linked to non-point pollution. At the same time the existence of intensive agriculture and extremely intensive livestock activity increases the potential for nitrate pollution in shallow groundwater. Nitrate used in agriculture could cause adverse effects on human and animal health. In order to evaluate the groundwater nitrate pollution, and how it might evolve in time, it is essential to develop control systems and to improve policies and incentives aimed at controlling the amount of nitrate entering downstream water systems. The province of Caserta in southern Italy is characterized by high levels of animal manure loading. A comparison between manure nitrogen production and nitrate concentration in groundwater was carried out in this area, using geostatistical tools and spatial statistics. The results show a discrepancy between modelling of nitrate leaching and monitoring of the groundwater and, moreover, no spatial correlation between nitrogen production in livestock farms and nitrate concentration in groundwater, suggesting that producers are not following the regulatory procedures for the agronomic use of manure. The methodology developed in this paper could be applied also in other regions in which European Union fertilization plans are not adequately followed.

  12. Ceramic Near-Net Shaped Processing Using Highly-Loaded Aqueous Suspensions

    Science.gov (United States)

    Rueschhoff, Lisa

    Ceramic materials offer great advantages over their metal counterparts, due to their lower density, higher hardness and wear resistance, and higher melting temperatures. However, the use of ceramics in applications where their properties would offer tremendous advantages are often limited due to the difficulty of forming them into complex and near-net shaped parts. Methods that have been developed to injection-mold or cast ceramics into more complicated shapes often use significant volume fractions of a carrier (often greater than 35 vol.% polymer), elevated temperature processing, or less-than-environmentally friendly chemicals where a complex chemical synthesis reaction must be timed perfectly for the approach to work. Furthermore, the continuing maturation of additive manufacturing methods requires a new approach for flowing/placing ceramic powders into useful designs. This thesis addresses the limitations of the current ceramic forming approaches by developing highly-stabilized and therefore high solids loading ceramic suspensions, with the requisite rheology for a variety of complex and near-net shaped forming techniques. Silicon nitride was chosen as a material of focus due to its high fracture toughness compared to other ceramic materials. Designing ceramic suspensions that are flowable at room temperature greatly simplifies processing as neither heating nor cooling are required during forming. Highly-loaded suspensions (>40 vol.%) are desired because all formed ceramic bodies have to be sintered to remove pores. Finally, using aqueous-based suspensions reduces any detrimental effect on the environment and tooling. The preparation of highly-loaded suspensions requires the development of a suitable dispersant through which particle-particle interactions are controlled. However, silicon nitride is difficult to stabilize in water due to complex surface and solution chemistry. In this study, aqueous silicon nitride suspensions up to 45 vol.% solids loading were

  13. High blood levels of persistent organic pollutants are statistically correlated with smoking

    DEFF Research Database (Denmark)

    Deutch, Bente; Hansen, Jens C.

    1999-01-01

    , smoking and intake of traditional Inuit food. Multiple linear regression analyses showed highly significant positive associations between the mothers' smoking status (never, previous, present) and plasma concentrations of all the studied organic pollutants both in maternal blood and umbilical cord blood......Persistent Organic Pollutants (11 pesticides and 14 PCB-congeners), and heavy metals (Cd, Cu, Hg, Pb, Se, and Zn) were determined in 175 pregnant women and 160 newborn infants (umbilical cord blood) from Disko Bay, Greenland, 1994-96. Among these, 135 women filled out questionnaires about drinking....... Traditional food and not the tobacco is known to be the source of the contaminants. But smoking may influence the enzymatic turnover of toxic substances....

  14. Nutrition Coupled with High-Load Traditional or Low-Load Blood Flow Restricted Exercise During Human Limb Suspension

    Science.gov (United States)

    Hackney, K. J.; Everett, M.; Ploutz-Snyder, L. L.

    2011-01-01

    High-load resistance exercise (HRE) and low-load blood flow restricted (BFR) exercise have demonstrated efficacy for attenuating unloading related muscle atrophy and dysfunction. In recreational exercisers, protein consumption immediately before and/or after exercise has been shown to increase the skeletal muscle anabolic response to resistance training. PURPOSE: To compare the skeletal muscle adaptations when chocolate milk intake was coupled with HRE or low-load BFR exercise [3 d/wk] during simulated lower limb weightlessness. METHODS: Eleven subjects were counterbalanced [based on age and gender] to HRE (31 +/- 14 yr, 170 +/- 13 cm, 71 +/- 18 kg, 2M/3W) or low-load BFR exercise (31 +/- 12 yr, 169 +/- 13 cm, 66 +/- 14 kg, 2M/4W) during 30 days of unilateral lower limb suspension (ULLS). Both HRE and BFR completed 3 sets of single leg press and calf raise exercise during ULLS. BFR exercise intensity was 20% of repetition maximum (1RM) with a cuff inflation pressure of 1.3 systolic blood pressure (143 4 mmHg). Cuff pressure was maintained during all 3 sets including rest intervals (90s). HRE intensity was 75% 1RM and was performed without cuff inflation. Immediately (HRE vs. BFR, respectively. Leg press training loads were 44 +/- 7 kg in HRE compared to 11 +/- 1 kg in BFR. Similarly, calf raise training loads were 81 +/- 11 kg in HRE and 16 +/- 1 kg in BFR. Pre to post-ULLS training adaptations in the unloaded leg are shown in the table. CONCLUSION: The preliminary results of this investigation suggest when HRE is optimized for muscle anabolism during unloading muscle size and strength are preserved (or enhanced) at the expense of muscle endurance. In contrast, when BFR exercise is optimized for muscle anabolism during unloading muscle endurance is preserved (or enhanced) at the expense of muscle size and strength

  15. 3D extrusion printing of high drug loading immediate release paracetamol tablets.

    Science.gov (United States)

    Khaled, Shaban A; Alexander, Morgan R; Wildman, Ricky D; Wallace, Martin J; Sharpe, Sonja; Yoo, Jae; Roberts, Clive J

    2018-03-01

    The manufacture of immediate release high drug loading paracetamol oral tablets was achieved using an extrusion based 3D printer from a premixed water based paste formulation. The 3D printed tablets demonstrate that a very high drug (paracetamol) loading formulation (80% w/w) can be printed as an acceptable tablet using a method suitable for personalisation and distributed manufacture. Paracetamol is an example of a drug whose physical form can present challenges to traditional powder compression tableting. Printing avoids these issues and facilitates the relatively high drug loading. The 3D printed tablets were evaluated for physical and mechanical properties including weight variation, friability, breaking force, disintegration time, and dimensions and were within acceptable range as defined by the international standards stated in the United States Pharmacopoeia (USP). X-ray Powder Diffraction (XRPD) was used to identify the physical form of the active. Additionally, XRPD, Attenuated Total Reflectance Fourier Transform Infrared spectroscopy (ATR-FTIR) and differential scanning calorimetry (DSC) were used to assess possible drug-excipient interactions. The 3D printed tablets were evaluated for drug release using a USP dissolution testing type I apparatus. The tablets showed a profile characteristic of the immediate release profile as intended based upon the active/excipient ratio used with disintegration in less than 60 s and release of most of the drug within 5 min. The results demonstrate the capability of 3D extrusion based printing to produce acceptable high-drug loading tablets from approved materials that comply with current USP standards. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Advances in High Power Calorimetric Matched Loads for Short Pulses and CW Gyrotrons

    International Nuclear Information System (INIS)

    Bin, W.M.; Bruschi, A.; Cirant, S.; Gandini, F.; Granucci, G.; Mellera, V.; Muzzini, V.; Nardone, A.; Sozzi, C.; Spinicchia, N.

    2006-01-01

    The development of high power gyrotrons for plasma physics research needs proper matched and calorimetric loads able to absorb and measure the power, which nowadays is foreseen to be as high as 2 MW during CW operations. To this end IFP/CNR has developed a family of matched loads useful in the mm-wave frequency band for applications ranging from a few ms to CW in pulse length. The different loads in the family, made of an integrating sphere with a partially reflecting coating on the inner wall, are characterized by having the same absorbing geometry for the incoming beam and a different heat removal system for the specific application. Some important advances have been recently achieved from the point of view of the uniformity of power distribution on the absorbing wall and of the load construction. With high precision achieved in the coating thickness a better control of the heating power distribution is possible by proper shaping of the local reflectivity, in addition to the shaping of the mirror dispersing the input beam. A more sophisticated model describing the power distribution has been developed, taking into account a variable thickness of the absorbing coating, the proper shape of the spreading mirror, the frequency of the incoming radiation and the shape of the input beam. Lower coating thickness is shown to be preferable, at equal local reflectivity, from the point of view of a lower peak temperature and thermal stress. The paper describes a load with variable coating thickness along the meridian of the sphere, showing a uniform power deposition on the inner walls. The cooling pipe is completely electroformed on the spherical copper shell, ensuring the maintenance of the correct curvature of the inner surface and a fast heat conduction from the absorbing coating to the water through the thin copper body. For CW use all heated parts of the load must be cooled and this is achieved by 16 electroformed spiral channels. Both short pulse loads (0.1-1 s) and

  17. Seasonal variation of physicochemical factor and fecal pollution in the Hansan-Geojeman area, Korea

    Directory of Open Access Journals (Sweden)

    Young Cheol Park

    2016-06-01

    Full Text Available Abstract The seasonal variation of fecal coliforms (FCs and physicochemical factors was determined in seawaters of the Hansan-Geojeman area, including a designated area for oyster, and in inland pollution sources of its drainage basin. The mean daily loads of FCs in inland pollution sources ranged from 1.2 × 109 to 3.1 × 1011 most probable number (MPN/day; however, the pollutants could not be reached at the designated area. FC concentrations of seawaters were closely related to season, rainfall, and inland contaminants, however, within the regulation limit of various countries for shellfish. The highest concentrations for chemical oxygen demand (COD and chlorophyll-a in seawaters were shown in the surface layer during August with high rainfall, whereas the lowest for dissolved oxygen (DO in the bottom layer of the same month. Therefore, it indicates that the concentrations of FC, COD, DO, and chlorophyll-a of seawaters were closely related to season and rainfall.

  18. Dual-Functional Ultrafiltration Membrane for Simultaneous Removal of Multiple Pollutants with High Performance.

    Science.gov (United States)

    Pan, Shunlong; Li, Jiansheng; Noonan, Owen; Fang, Xiaofeng; Wan, Gaojie; Yu, Chengzhong; Wang, Lianjun

    2017-05-02

    Simultaneous removal of multiple pollutants from aqueous solution with less energy consumption is crucial in water purification. Here, a novel concept of dual-functional ultrafiltration (DFUF) membrane is demonstrated by entrapment of nanostructured adsorbents into the finger-like pores of ultrafiltration (UF) membrane rather than in the membrane matrix in previous reports of blend membranes, resulting in an exceptionally high active content and simultaneous removal of multiple pollutants from water due to the dual functions of rejection and adsorption. As a demonstration, hollow porous Zr(OH) x nanospheres (HPZNs) were immobilized in poly(ether sulfone) (PES) UF membranes through polydopamine coating with a high content of 68.9 wt %. The decontamination capacity of DFUF membranes toward multiple model pollutants (colloidal gold, polyethylene glycol (PEG), Pb(II)) was evaluated against a blend membrane. Compared to the blend membrane, the DFUF membranes showed 2.1-fold increase in the effective treatment volume for the treatment of Pb(II) contaminated water from 100 ppb to below 10 ppb (WHO drinking water standard). Simultaneously, the DFUF membranes effectively removed the colloidal gold and PEG below instrument detection limit, however the blend membrane only achieved 97.6% and 96.8% rejection for colloidal gold and PEG, respectively. Moreover, the DFUF membranes showed negligible leakage of nanoadsorbents during testing; and the membrane can be easily regenerated and reused. This study sheds new light on the design of high performance multifunction membranes for drinking water purification.

  19. Setting limits: Using air pollution thresholds to protect and restore U.S. ecosystems

    Science.gov (United States)

    Fenn, M.E.; Lambert, K.F.; Blett, T.F.; Burns, Douglas A.; Pardo, L.H.; Lovett, Gary M.; Haeuber, R. A.; Evers, D.C.; Driscoll, C.T.; Jeffries, D.S.

    2011-01-01

    states and on many tribal lands. High concentrations of mercury in wildlife are also widespread and have multiple adverse effects. ??? Air quality programs, such as those stemming from the 1990 Clean Air Act Amendments, have helped decrease air pollution even as population and energy demand have increased. Yet, they do not adequately protect ecosystems from long-term damage. Moreover they do not address ammonia emissions. ??? A stronger ecosystem basis for air pollutant policies could be established through adoption of science-based thresholds. Existing monitoring programs track vital information needed to measure the response to policies, and could be expanded to include appropriate chemical and biological indicators for terrestrial and aquatic ecosystems and establishment of a national ecosystem monitoring network for mercury. The development and use of air pollution thresholds for ecosystem protection and management is increasing in the United States, yet threshold approaches remain underutilized. Ecological thresholds for air pollution, such as critical loads for nitrogen and sulfur deposition, are not currently included in the formal regulatory process for emissions controls in the United States, although they are now considered in local management decisions by the National Park Service and U.S. Forest Service. Ecological thresholds offer a scientifically sound approach to protecting and restoring U.S. ecosystems and an important tool for natural resource management and policy. ?? The Ecological Society of America.

  20. Runoff characteristics and non-point source pollution analysis in the Taihu Lake Basin: a case study of the town of Xueyan, China.

    Science.gov (United States)

    Zhu, Q D; Sun, J H; Hua, G F; Wang, J H; Wang, H

    2015-10-01

    Non-point source pollution is a significant environmental issue in small watersheds in China. To study the effects of rainfall on pollutants transported by runoff, rainfall was monitored in Xueyan town in the Taihu Lake Basin (TLB) for over 12 consecutive months. The concentrations of different forms of nitrogen (N) and phosphorus (P), and chemical oxygen demand, were monitored in runoff and river water across different land use types. The results indicated that pollutant loads were highly variable. Most N losses due to runoff were found around industrial areas (printing factories), while residential areas exhibited the lowest nitrogen losses through runoff. Nitrate nitrogen (NO3-N) and ammonia nitrogen (NH4-N) were the dominant forms of soluble N around printing factories and hotels, respectively. The levels of N in river water were stable prior to the generation of runoff from a rainfall event, after which they were positively correlated to rainfall intensity. In addition, three sites with different areas were selected for a case study to analyze trends in pollutant levels during two rainfall events, using the AnnAGNPS model. The modeled results generally agreed with the observed data, which suggests that AnnAGNPS can be used successfully for modeling runoff nutrient loading in this region. The conclusions of this study provide important information on controlling non-point source pollution in TLB.

  1. High heat load properties of TiC dispersed Mo alloys

    International Nuclear Information System (INIS)

    Tokunaga, Kazutoshi; Yoshida, Naoaki; Miura, Yasushi; Kurishita, Hiroaki; Kitsunai, Yuji; Kayano, Hideo.

    1996-01-01

    Electron beam high heat load experiment of new developed three kinds of TiC dispersed Mo alloys (Mo-0.1wt%TiC, Mo-0.5wt%TiC and Mo-1.0wt%TiC) was studied so as to evaluate it's high heat load at using as the surface materials of divertor. The obtained results indicated that cracks were not observed by embrittlement by recrystallization until about 2200degC of surface temperature and the gas emission properties were not different from sintered molibdenum. However, at near melting point, deep cracks on grain boundary and smaller gas emission than that of sintered Mo were observed. So that, we concluded that TiC dispersed Mo alloy was good surface materials used under the conditions of the stationary heat flux and less than the melting point, although not good one to be melted under nonstationary large heat flux. (S.Y.)

  2. Characterizing occipital condyle loads under high-speed head rotation.

    Science.gov (United States)

    Pintar, Frank A; Yoganandan, Narayan; Baisden, Jamie

    2005-11-01

    Because of the need to evaluate anthropomorphic test device (ATD) biofidelity under high-head angular accelerations, the purpose of the present investigation was to develop appropriate instrumentation for intact post mortem human subject (PMHS) testing, validate the instrumentation, and obtain information to characterize the response of the head-neck complex under this loading scenario. A series of rigid-arm pendulum, inertially loaded ATD tests was conducted. Head and neck ATD hydraulic piston chin pull tests were conducted. Subsequently, a series of PMHS tests was conducted to derive the response of the human head-neck under high-rate chin loading. Finally, Hybrid III and THOR-NT ATD head-neck systems were evaluated under the same scenario as the PMHS. A parametric analysis for center of gravity (CG) location and accelerometer orientation determined that even small errors (+/- 3 mm or 2 degrees), produced errors in the force and moment calculations by as much as 17 %. If the moment of inertia (MOI) term was varied by 5 %, resulting moment calculations were affected by as much as 8 %. If the 5 % error in MOI was used to compute occipital condyle moments, and results compared to upper load cell derived moments, peaks differed by as much as 24 %. The head CG and mass MOI should be directly measured for each preparation to obtain accurate results. The injury run on each specimen resulted in predominantly C1-C2 separations or partial separations. The 50(th) percentile probability of AIS=2+ neck injury using tensile force was about 2400 N; for AIS=3+ neck injury the 50(th) percentile risk was about 3180 N. When inserting extension moment as the criteria, the 50(th) percentile probability of an AIS=2+ injury was 51 Nm. The AIS=3+ extension moment at the 50(th) percentile probability was 75 Nm. The new THOR-NT ATD head-neck produced more biofidelic responses with an alternate head-neck junction design compared to the Hybrid III ATD.

  3. Synthesis and photocatalytic activity of carbon spheres loaded Cu2O/Cu composites

    International Nuclear Information System (INIS)

    Li, Yinhui; Zhao, Mengyao; Zhang, Na; Li, Ruijuan; Chen, Jianxin

    2015-01-01

    Highlights: • Carbon spheres loaded Cu 2 O/Cu composites are obtained by hydrothermal process. • Cu 2 O/Cu nanocrystals grow on the surface of carbon spheres. • The composites with core–shell structure show highly photo-catalytic activity. • The composites can degrade methyl orange under simulated solar light irradiation. • The composites can be used to treat dye wastewater or organic pollutants. - Abstract: In this work, using amylose as carbon source and cupric acetate as copper source, carbon spheres loaded Cu 2 O/Cu composites were obtained by hydrothermal synthesis. The effects of the molar ratios between glucose and Cu(II), and hydrothermal time on the morphology and sizes of the composites were investigated. The result of photocatalytic experiments demonstrated that the composites could degrade methyl orange in aqueous solution under simulated solar light irradiation. The highest degradation rate was achieved to 93.83% when the composites were prepared by hydrothermal synthesis at 180 °C for 16 h and the molar ratio between glucose and Cu(II) was 10/1. The composites, as new and promising materials, can be used to treat dye wastewater or other organic pollutants

  4. North American pollution measurements from geostationary orbit with Tropospheric Emissions: Monitoring of Pollution (TEMPO)

    Science.gov (United States)

    Chance, K.

    2017-12-01

    TEMPO is the first NASA Earth Venture Instrument. It launches between 2019 and 2021 to measure atmospheric pollution from Mexico City and Cuba to the Canadian oil sands, and from the Atlantic to the Pacific, hourly at high spatial resolution, 10 km2. Geostationary daytime measurements capture the variability in the diurnal cycle of emissions and chemistry at sub-urban scale to improve emission inventories, monitor population exposure, and enable emission-control strategies.TEMPO measures UV/visible Earth reflectance spectra to retrieve O3, NO2, SO2, H2CO, C2H2O2, H2O, BrO, OClO, IO, aerosols, cloud parameters, and UVB radiation. It tracks aerosol loading. It provides near-real-time air quality products. TEMPO is the North American component of the upcoming the global geostationary constellation for pollution monitoring, together with the European Sentinel-4 and the Korean Geostationary Environmental Monitoring Spectrometer (GEMS).TEMPO science studies include: Intercontinental pollution transport; Solar-induced fluorescence from chlorophyll over land and in the ocean to study tropical dynamics, primary productivity and carbon uptake, to detect red tides, and to study phytoplankton; measurements of stratospheric intrusions that cause air quality exceedances; measurements at peaks in vehicle travel to capture the variability in emissions from mobile sources; measurements of thunderstorm activity, including outflow regions to better quantify lightning NOx and O3 production; cropland measurements to follow the temporal evolution of emissions after fertilizer application and from rain-induced emissions from semi-arid soils; investigating the chemical processing of primary fire emissions and the secondary formation of VOCs and ozone; examining ocean halogen emissions and their impact on the oxidizing capacity of coastal environments; measuring spectra of nighttime lights as markers for human activity, energy conservation, and compliance with outdoor lighting standards

  5. Application of the critical loads approach in South Africa

    CSIR Research Space (South Africa)

    Van Tienhoven, AM

    1995-12-01

    Full Text Available , South Africa. Abstract. South Africa is the most industrialised country in southern Africa and stands at some risk from negative pollution i apa~ To the authors' knowledge, this paper presents the first attempt toapply the critical loads approach...

  6. National implementation of the UNECE convention on long-range transboundary air pollution (effects). Pt. 2. Impacts and risk estimation, critical loads, biodiversity, dynamic modelling, critical level violation, material corrosion; Nationale Umsetzung UNECE-Luftreinhaltekonvention (Wirkungen). T. 2. Wirkungen und Risikoabschaetzungen Critical Loads, Biodiversitaet, Dynamische Modellierung, Critical Levels Ueberschreitungen, Materialkorrosion

    Energy Technology Data Exchange (ETDEWEB)

    Gauger, Thomas [Bundesforschungsanstalt fuer Landwirtschaft, Braunschweig (DE). Inst. fuer Agraroekologie (FAL-AOE); Stuttgart Univ. (Germany). Inst. fuer Navigation; Haenel, Hans-Dieter; Roesemann, Claus [Bundesforschungsanstalt fuer Landwirtschaft, Braunschweig (DE). Inst. fuer Agraroekologie (FAL-AOE); Nagel, Hans-Dieter; Becker, Rolf; Kraft, Philipp; Schlutow, Angela; Schuetze, Gudrun; Weigelt-Kirchner, Regine [OeKO-DATA Gesellschaft fuer Oekosystemanalyse und Umweltdatenmanagement mbH, Strausberg (Germany); Anshelm, Frank [Geotechnik Suedwest Frey Marx GbR, Bietigheim-Bissingen (Germany)

    2008-09-15

    The report on the implementation of the UNECE convention on long-range transboundary air pollution Pt.2 covers the following issues: The tasks of the NFC (National Focal Center) Germany including the ICP (international cooperative program) modeling and mapping and the expert panel for heavy metals. Results of the work for the multi-component protocol cover the initial data for the calculation of the critical loads following the mass balance method, critical loads for acid deposition, critical loads for nitrogen input, critical load violations (sulfur, nitrogen). The results of work for the heavy metal protocol cover methodology development and recommendations for ICO modeling and mapping in accordance with international development, contributions of the expert group/ task force on heavy metals (WGSR), data sets on the critical loads for lead, cadmium and mercury, and critical load violations (Pb, Cd, Hg). The results of work on the inclusion of biodiversity (BERN) cover data compilation, acquisition and integration concerning ecosystems, model validation and verification and the possible interpretation frame following the coupling with dynamic modeling. The future development and utilization of dynamic modeling covers model comparison, applicability, the preparation of a national data set and preparations concerning the interface to the BERN model.

  7. Next Day Subjective and Objective Recovery Indices Following Acute Low and High Training Loads in Academy Rugby Union Players

    Directory of Open Access Journals (Sweden)

    Mark R. Noon

    2018-06-01

    Full Text Available The aim of this study was to determine the sensitivity of selected subjective and objective monitoring assessments in detecting changes in group and individual responses to low and high load bouts of high intensity intermittent exercise. In a counterbalanced crossover design, Thirteen Academy Rugby Union players (mean ± SD: age: 18 ± 1 years performed a low load (15 min and a high load (90 min bout of high intensity intermittent exercise (Loughborough Intermittent Shuttle Test one week apart. Monitoring assessments were performed immediately prior to and 20 h following each trial. Subjective self-report Well-being Questionnaire (WQ items showed small to large deteriorations following the high load compared to low load (d = 0.4–1.5, p = 0.03–0.57. A very large increase in resting HR (HRrest (d = 2.1, p = 0.02, moderate decrease in heart rate variability (HRV indices (d = 0.7, p = 0.04 and d = 0.7, p = 0.01 for the natural logarithm of the standard deviation of R-R intervals (ln SDNN and the root square of the mean squared differences of successive R-R intervals (rMSSD, respectively and no change in countermovement jump (d = 0.0, p = 0.97 were evident following the high load compared to low load. Individual WQ responses revealed 7/9, 7/9, 6/9, 6/9, 5/9, 3/9 and 1/9 participants reported deteriorations in recovery, sleep quality, motivation, muscle soreness, fatigue, stress and appetite, respectively, following the high load compared to low load. Individual analysis indicated a negative response following the high load compared to low load in HRrest, ln SDNN and ln rMSSD for 4/6, 2/6 and 1/6 participants, respectively. Selected WQ items detected group and individual responses to high load and low load highlighting their potential utility. However, objective assessments lacked the sensitivity to detect small individual changes.

  8. Load balancing in highly parallel processing of Monte Carlo code for particle transport

    International Nuclear Information System (INIS)

    Higuchi, Kenji; Takemiya, Hiroshi; Kawasaki, Takuji

    1998-01-01

    In parallel processing of Monte Carlo (MC) codes for neutron, photon and electron transport problems, particle histories are assigned to processors making use of independency of the calculation for each particle. Although we can easily parallelize main part of a MC code by this method, it is necessary and practically difficult to optimize the code concerning load balancing in order to attain high speedup ratio in highly parallel processing. In fact, the speedup ratio in the case of 128 processors remains in nearly one hundred times when using the test bed for the performance evaluation. Through the parallel processing of the MCNP code, which is widely used in the nuclear field, it is shown that it is difficult to attain high performance by static load balancing in especially neutron transport problems, and a load balancing method, which dynamically changes the number of assigned particles minimizing the sum of the computational and communication costs, overcomes the difficulty, resulting in nearly fifteen percentage of reduction for execution time. (author)

  9. Cerebral blood flow, fatigue, mental effort, and task performance in offices with two different pollution loads

    DEFF Research Database (Denmark)

    Nishihara, Naoe; Wargocki, Pawel; Tanabe, Shin-ichi

    2014-01-01

    The effects of indoor air quality on symptoms, perceptions, task performance, cerebral blood flow, fatigue, and mental effort of individuals working in an office were investigated. Twenty-four right-handed Danish female subjects in an office were exposed in groups of two at a time to two air...... pollution levels created by placing or removing a pollution source (i.e. a used carpet) behind a screen. During the exposure, the subjects performed four different office tasks presented on a computer monitor. The tasks were performed at two paces: normal and maximum. When the pollution source was present...... any effects caused by modifying pollution exposure, they were well correlated with increased mental effort when the tasks were performed at maximum pace and subjectively reported fatigue, which increased during the course of exposure, respectively....

  10. Event-based nonpoint source pollution prediction in a scarce data catchment

    Science.gov (United States)

    Chen, Lei; Sun, Cheng; Wang, Guobo; Xie, Hui; Shen, Zhenyao

    2017-09-01

    Quantifying the rainfall-runoff-pollutant (R-R-P) process is key to regulating non-point source (NPS) pollution; however, the impacts of scarce measured data on R-R-P simulations have not yet been reported. In this study, we conducted a comprehensive study of scarce data that addressed both rainfall-runoff and runoff-pollutant processes, whereby the impacts of data scarcity on two commonly used methods, including Unit Hydrograph (UH) and Loads Estimator (LOADEST), were quantified. A case study was performed in a typical small catchment of the Three Gorges Reservoir Region (TGRR) of China. Based on our results, the classification of rainfall patterns should be carried out first when analyzing modeling results. Compared to data based on a missing rate and a missing location, key information generates more impacts on the simulated flow and NPS loads. When the scarcity rate exceeds a certain threshold (20% in this study), measured data scarcity level has clear impacts on the model's accuracy. As the model of total nitrogen (TN) always performs better under different data scarcity conditions, researchers are encouraged to pay more attention to continuous the monitoring of total phosphorus (TP) for better NPS-TP predictions. The results of this study serve as baseline information for hydrologic forecasting and for the further control of NPS pollutants.

  11. Dust pollution of snow cover in the industrial areas of Tomsk city (Western Siberia, Russia)

    Science.gov (United States)

    Talovskaya, A. V.; Filimonenko, E. A.; Osipova, N. A.; Yazikov, E. G.; Nadeina, L. V.

    2016-03-01

    This article describes the results of long-term monitoring (2007-2014) of snow cover pollution in the territory of Tomsk city. Snow samples were collected in the territory of Tomsk. Determination of dust load level was carried out by comparing with the background and reference values. It has been determined that the north-east and central parts of Tomsk are the most contaminated areas, where brickworks, coal and gas-fired thermal power plant are located. The analysis of long-term dynamics showed a dust load decrease in the vicinity of coal and gas-fired thermal power plant due to upgrading of the existing dust collecting systems. During the monitoring period the high dust load in the vicinity of brickworks did not change. The lowest value of the dust load on snow cover was detected in the vicinity of the petrochemical plant and concrete product plants. The near and far zones of dust load on snow cover were determined with the reference to the location of the studied plants.

  12. Domestic smoke exposure is associated with alveolar macrophage particulate load.

    Science.gov (United States)

    Fullerton, Duncan G; Jere, Khuzwayo; Jambo, Kondwani; Kulkarni, Neeta S; Zijlstra, Eduard E; Grigg, Jonathan; French, Neil; Molyneux, Malcolm E; Gordon, Stephen B

    2009-03-01

    Indoor air pollution is associated with impaired respiratory health. The pre-dominant indoor air pollutant to which two billion of the world's population is exposed is biomass fuel smoke. We tested the hypothesis that reported smoke exposure in men and women is associated with increased alveolar macrophage uptake of biomass smoke particulates. Healthy volunteers attending for research bronchoscopy in Malawi completed a questionnaire assessment of smoke exposure. Particulate matter visible in alveolar macrophages (AM) was quantified using digital image analysis. The geometric mean of the percentage area of the cytoplasm occupied by particulates in 50 cover-slip adherent AM was calculated and termed particulate load. In 57 subjects (40 men and 17 women) there was a significant difference between the particulate load in groups divided according to pre-dominant lighting form used at home (ANOVA P = 0.0009) and type of cooking fuel (P = 0.0078). Particulate load observed in macrophages is associated with the reported type of biomass fuel exposure. Macrophage function in relation to respiratory health should now be investigated in biomass smoke exposed subjects.

  13. High Level Waste (HLW) Processing Experience with Increased Waste Loading

    International Nuclear Information System (INIS)

    JANTZEN, CAROL

    2004-01-01

    The Defense Waste Processing Facility (DWPF) Engineering requested characterization of glass samples that were taken after the second melter had been operational for about 5 months. After the new melter had been installed, the waste loading had been increased to about 38 weight percentage after a new quasicrystalline liquidus model had been implemented. The DWPF had also switched from processing with refractory Frit 200 to a more fluid Frit 320. The samples were taken after DWPF observed very rapid buildup of deposits in the upper pour spout bore and on the pour spout insert while processing the high waste loading feedstock. These samples were evaluated using various analytical techniques to determine the cause of the crystallization. The pour stream sample was homogeneous, amorphous, and representative of the feed batch from which it was derived. Chemical analysis of the pour stream sample indicated that a waste loading of 38.5 weight per cent had been achieved. The data analysis indicated that surface crystallization, induced by temperature and oxygen fugacity gradients in the pour spout, caused surface crystallization to occur in the spout and on the insert at the higher waste loadings even though there was no crystallization in the pour stream

  14. Local scale air pollution forecasting by artificial intelligence techniques and assess the pollution-related social effects

    OpenAIRE

    Gong, Bing; Ordieres-Meré, Joaquín

    2016-01-01

    Since the air pollution can cause serious health problem, the concerns about forecasting air pollution timely and accurately arise by researchers in order to alert the public avoiding high level pollution and help the government make decisions. In our research, we take Hong Kong (finished research) and the cities in Mexico (finishing) and Mainland China (starting), especially the high pollutant areas such as Mexico City and Beijing, as study cases. Meanwhile, various types of arti...

  15. Modeling and Depletion Simulations for a High Flux Isotope Reactor Cycle with a Representative Experiment Loading

    Energy Technology Data Exchange (ETDEWEB)

    Chandler, David [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Reactor and Nuclear Systems Division; Betzler, Ben [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Reactor and Nuclear Systems Division; Hirtz, Gregory John [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Reactor and Nuclear Systems Division; Ilas, Germina [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Reactor and Nuclear Systems Division; Sunny, Eva [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Reactor and Nuclear Systems Division

    2016-09-01

    The purpose of this report is to document a high-fidelity VESTA/MCNP High Flux Isotope Reactor (HFIR) core model that features a new, representative experiment loading. This model, which represents the current, high-enriched uranium fuel core, will serve as a reference for low-enriched uranium conversion studies, safety-basis calculations, and other research activities. A new experiment loading model was developed to better represent current, typical experiment loadings, in comparison to the experiment loading included in the model for Cycle 400 (operated in 2004). The new experiment loading model for the flux trap target region includes full length 252Cf production targets, 75Se production capsules, 63Ni production capsules, a 188W production capsule, and various materials irradiation targets. Fully loaded 238Pu production targets are modeled in eleven vertical experiment facilities located in the beryllium reflector. Other changes compared to the Cycle 400 model are the high-fidelity modeling of the fuel element side plates and the material composition of the control elements. Results obtained from the depletion simulations with the new model are presented, with a focus on time-dependent isotopic composition of irradiated fuel and single cycle isotope production metrics.

  16. Residential Air Pollution, Road Traffic, Greenness and Maternal Hypertension: Results from GINIplus and LISAplus

    Directory of Open Access Journals (Sweden)

    Mario Jendrossek

    2017-07-01

    Full Text Available Background: The public health burden of hypertension is high, but its relationship with long-term residential air pollution, road traffic, and greenness remains unclear. Objective: To investigate associations between residential air pollution, traffic, greenness, and hypertension among mothers. Methods: Information on doctor-diagnosed maternal hypertension was collected at the 15-year follow-up of two large population-based multicenter German birth cohorts—GINIplus and LISAplus (n=3063. Residential air pollution was modelled by land use regression models within the ESCAPE and universal kriging within the APMoSPHERE projects. Road traffic was defined as traffic load on major roads within a 100-m buffer around residences. Vegetation level (ie, greenness was defined as the mean Normalized Difference Vegetation Index in a 500-m buffer around residences and was assessed from Landsat 5 TM satellite images. All the exposure variables were averaged over three residential addresses during the last 10 years and categorized into tertiles or dichotomized. The individual associations between each of the exposure variables and hypertension were assessed using logistic regression analysis. Results: No significant and consistent associations across different levels of adjustment were observed between the exposures of interest and hypertension. The only significant estimate was found with coarse particulate matter concentrations (OR 1.66, 95% CI 1.01 to 2.74; 3rd vs 1st tertile among mothers residing in the Wesel area. No significant associations were observed with traffic load or greenness. Conclusion: This study does not provide evidence on detrimental effects of air pollution and road traffic or beneficial effects of greenness on hypertension among German adults.

  17. Enhanced microwave shielding and mechanical properties of high loading MWCNT–epoxy composites

    International Nuclear Information System (INIS)

    Singh, B. P.; Prasanta; Choudhary, Veena; Saini, Parveen; Pande, Shailaja; Singh, V. N.; Mathur, R. B.

    2013-01-01

    Dispersion of high loading of carbon nanotubes (CNTs) in epoxy resin is a challenging task for the development of efficient and thin electromagnetic interference (EMI) shielding materials. Up to 20 wt% of multiwalled carbon nanotubes (MWCNTs) loading in the composite was achieved by forming CNT prepreg in the epoxy resin as a first step. These prepreg laminates were then compression molded to form composites which resulted in EMI shielding effectiveness of −19 dB for 0.35 mm thick film and −60 dB at for 1.75 mm thick composites in the X-band (8.2–12.4 GHz). One of the reasons for such high shielding is attributed to the high electrical conductivity of the order of 9 S cm −1 achieved in these composites which is at least an order of magnitude higher than previously reported results at this loading. In addition, an improvement of 40 % in the tensile strength over the neat resin value is observed. Thermal conductivity of the MWCNTs–epoxy composite reached 2.18 W/mK as compared to only 0.14 W/mK for cured epoxy.

  18. Enhanced microwave shielding and mechanical properties of high loading MWCNT-epoxy composites

    Science.gov (United States)

    Singh, B. P.; Prasanta; Choudhary, Veena; Saini, Parveen; Pande, Shailaja; Singh, V. N.; Mathur, R. B.

    2013-04-01

    Dispersion of high loading of carbon nanotubes (CNTs) in epoxy resin is a challenging task for the development of efficient and thin electromagnetic interference (EMI) shielding materials. Up to 20 wt% of multiwalled carbon nanotubes (MWCNTs) loading in the composite was achieved by forming CNT prepreg in the epoxy resin as a first step. These prepreg laminates were then compression molded to form composites which resulted in EMI shielding effectiveness of -19 dB for 0.35 mm thick film and -60 dB at for 1.75 mm thick composites in the X-band (8.2-12.4 GHz). One of the reasons for such high shielding is attributed to the high electrical conductivity of the order of 9 S cm-1 achieved in these composites which is at least an order of magnitude higher than previously reported results at this loading. In addition, an improvement of 40 % in the tensile strength over the neat resin value is observed. Thermal conductivity of the MWCNTs-epoxy composite reached 2.18 W/mK as compared to only 0.14 W/mK for cured epoxy.

  19. Rainfall-induced runoff from exposed streambed sediments: an important source of water pollution.

    Science.gov (United States)

    Frey, S K; Gottschall, N; Wilkes, G; Grégoire, D S; Topp, E; Pintar, K D M; Sunohara, M; Marti, R; Lapen, D R

    2015-01-01

    When surface water levels decline, exposed streambed sediments can be mobilized and washed into the water course when subjected to erosive rainfall. In this study, rainfall simulations were conducted over exposed sediments along stream banks at four distinct locations in an agriculturally dominated river basin with the objective of quantifying the potential for contaminant loading from these often overlooked runoff source areas. At each location, simulations were performed at three different sites. Nitrogen, phosphorus, sediment, fecal indicator bacteria, pathogenic bacteria, and microbial source tracking (MST) markers were examined in both prerainfall sediments and rainfall-induced runoff water. Runoff generation and sediment mobilization occurred quickly (10-150 s) after rainfall initiation. Temporal trends in runoff concentrations were highly variable within and between locations. Total runoff event loads were considered large for many pollutants considered. For instance, the maximum observed total phosphorus runoff load was on the order of 1.5 kg ha. Results also demonstrate that runoff from exposed sediments can be a source of pathogenic bacteria. spp. and spp. were present in runoff from one and three locations, respectively. Ruminant MST markers were also present in runoff from two locations, one of which hosted pasturing cattle with stream access. Overall, this study demonstrated that rainfall-induced runoff from exposed streambed sediments can be an important source of surface water pollution. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  20. High Working Memory Load Increases Intracortical Inhibition in Primary Motor Cortex and Diminishes the Motor Affordance Effect.

    Science.gov (United States)

    Freeman, Scott M; Itthipuripat, Sirawaj; Aron, Adam R

    2016-05-18

    Motor affordances occur when the visual properties of an object elicit behaviorally relevant motor representations. Typically, motor affordances only produce subtle effects on response time or on motor activity indexed by neuroimaging/neuroelectrophysiology, but sometimes they can trigger action itself. This is apparent in "utilization behavior," where individuals with frontal cortex damage inappropriately grasp affording objects. This raises the possibility that, in healthy-functioning individuals, frontal cortex helps ensure that irrelevant affordance provocations remain below the threshold for actual movement. In Experiment 1, we tested this "frontal control" hypothesis by "loading" the frontal cortex with an effortful working memory (WM) task (which ostensibly consumes frontal resources) and examined whether this increased EEG measures of motor affordances to irrelevant affording objects. Under low WM load, there were typical motor affordance signatures: an event-related desynchronization in the mu frequency and an increased P300 amplitude for affording (vs nonaffording) objects over centroparietal electrodes. Contrary to our prediction, however, these affordance measures were diminished under high WM load. In Experiment 2, we tested competing mechanisms responsible for the diminished affordance in Experiment 1. We used paired-pulse transcranial magnetic stimulation over primary motor cortex to measure long-interval cortical inhibition. We found greater long-interval cortical inhibition for high versus low load both before and after the affording object, suggesting that a tonic inhibition state in primary motor cortex could prevent the affordance from provoking the motor system. Overall, our results suggest that a high WM load "sets" the motor system into a suppressed state that mitigates motor affordances. Is an irrelevant motor affordance more likely to be triggered when you are under low or high cognitive load? We examined this using physiological measures

  1. Greenidge Multi-Pollutant Control Project

    Energy Technology Data Exchange (ETDEWEB)

    Connell, Daniel

    2008-10-18

    CONSOL Energy Inc. as prime contractor, AES Greenidge LLC as host site owner, and Babcock Power Environmental Inc. as engineering, procurement, and construction contractor. About 44% of the funding for the project was provided by the U.S. Department of Energy, through its National Energy Technology Laboratory, and the remaining 56% was provided by AES Greenidge. Project goals included reducing high-load NO{sub x} emissions to {le} 0.10 lb/mmBtu; reducing SO{sub 2}, SO{sub 3}, HCl, and HF emissions by at least 95%; and reducing Hg emissions by at least 90% while the unit fired 2-4% sulfur eastern U.S. bituminous coal and co-fired up to 10% biomass. This report details the final results from the project. The multi-pollutant control system was constructed in 2006, with a total plant cost of $349/kW and a footprint of 0.4 acre - both substantially less than would have been required to retrofit AES Greenidge Unit 4 with a conventional SCR and wet scrubber. Start-up of the multi-pollutant control system was completed in March 2007, and the performance of the system was then evaluated over an approximately 18-month period of commercial operation. Guarantee tests conducted in March-June 2007 demonstrated attainment of all of the emission reduction goals listed above. Additional tests completed throughout the performance evaluation period showed 96% SO{sub 2} removal, 98% mercury removal (with no activated carbon injection), 95% SO{sub 3} removal, and 97% HCl removal during longer-term operation. Greater than 95% SO{sub 2} removal efficiency was observed even when the unit fired high-sulfur coals containing up to 4.8 lb SO{sub 2}/mmBtu. Particulate matter emissions were reduced by more than 98% relative to the emission rate observed prior to installation of the technology. The performance of the hybrid SNCR/SCR system was affected by problems with large particle ash, ammonia slip, and nonideal combustion characteristics, and high-load NO{sub x} emissions averaged 0.14 lb

  2. Diffusion pollution from livestock and poultry rearing in the Yangtze Delta, China.

    Science.gov (United States)

    Gu, Pei; Shen, Ren Fang; Chen, Yi Ding

    2008-05-01

    The Yangtze Delta is one of the most developed regions in China and includes Shanghai, eight cities in Jiangsu province and eight cities in Zhejiang province. Meat consumption in this region has increased with economic growth, and most of the consumed meat is produced locally. The water quality of surface waters has deteriorated in recent years. An example was the huge blue-green algae bloom in Tai Lake in late May 2007, which affected millions of people's daily drinking water. However, animal husbandry is considered to be one of the main pollution sources. Pollutants (NH3-N, total phosphorus (TP), and total nitrogen (TN)) excreted by livestock and poultry, and the resultant COD (chemical oxygen demand) and BOD (biochemical oxygen demand), were estimated using two different methods based on different data sets. The number of livestock and poultry has remained stable in the Yangtze Delta over the four years from 1999 to 2002, with the average number of pigs, cattle, sheep and poultry being 21.1 M, 0.4 M, 7.7 M and 597.6 M, respectively. Pollutants in livestock and poultry excreta estimated by Method I were: 0.12 Mt NH3-N, 0.11 Mt TP and 0.29 Mt TN, resulting in COD and BOD of 1.34 Mt and 1.30 Mt, respectively, while the estimations based on Method II were: 0.18 Mt NH3-N, 0.15 Mt TP and 0.40 Mt TN, resulting in COD and BOD of 1.95 Mt and 1.80 Mt, respectively. Pollutants excreted annually by livestock and poultry in the Yangtze Delta are estimated to be: 0.17 Mt NH3-N, 0.16 Mt TP and 0.42 Mt TN, giving rise to a COD of 1.86 Mt and a BOD of 1.72 Mt. Approximately 25% of this pollution was estimated to enter water bodies, which means that the annual pollutant load is 43,700 t NH3-N, 39,400 tTP, 104,600t TN with a COD of 465,000 tand a BOD of 430,100 t. Pollutants from animal husbandry were similar in magnitude to those from industrial wastewater. Pigs produced the most pollution, followed by poultry, cattle and sheep. The pollution load from animal husbandry in the

  3. Geochemical assessment of heavy metals pollution in surface sediments of Vellar and Coleroon estuaries, southeast coast of India.

    Science.gov (United States)

    Nethaji, S; Kalaivanan, R; Arya Viswam; Jayaprakash, M

    2017-02-15

    Surface sediments were collected from Vellar and Coleroon estuaries for determine sediment texture, calcium carbonate, organic matter and heavy metals. Pollution indices such as pollution load index (PLI), contamination factor (CF), enrichment factor (EF) and geo-accumulation index (I geo ) were done for this study to know the level of heavy metals pollution in the estuarine ecosystem. Pearson correlation matrix and factor were used to assess the relationship and source of heavy metals in the estuarine sediments. The results of PLI values reveal that the study area was polluted by all the heavy metals. The calculated values of CF and I geo followed the decreasing order Cu>Ni>Pb>Co>Cr>Zn>Mn>Fe and illustrate that Cu, Ni and Pb are contaminated due to anthropogenic sources in both estuaries. Correlation and factor analysis suggest that FeMn oxyhydroxides, organic matter and fine particles are responsible for high concentration of heavy metals. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Harvest season, high polluted season in East China

    International Nuclear Information System (INIS)

    Huang Xin; Song Yu; Li Mengmeng; Li Jianfeng; Zhu Tong

    2012-01-01

    East China, a major agricultural zone with a dense population, suffers from severe air pollution during June, the agricultural harvest season, every year. Crop burning emits tremendous amounts of combustion products into the atmosphere, not only rapidly degrading the local air quality but also affecting the tropospheric chemistry, threatening public health and affecting climate change. Recently, in mid-June 2012, crop fires left a thick pall of haze over East China. We evaluated the PM 10 , PM 2.5 (particulates less than 10 and 2.5 μm in aerodynamic diameter) and BC (black carbon) emissions by analyzing detailed census data and moderate resolution imaging spectroradiometer (MODIS) remote sensing images and then simulated the consequent pollution using meteorological and dispersion models. The results show that the crop fires sweeping from the south to the north are responsible for the intensive air pollution during harvest season. It is necessary for scientists and governments to pay more attention to this issue. (letter)

  5. Assessing the Long Term Impact of Phosphorus Fertilization on Phosphorus Loadings Using AnnAGNPS

    OpenAIRE

    Yuan, Yongping; Bingner, Ronald L.; Locke, Martin A.; Stafford, Jim; Theurer, Fred D.

    2011-01-01

    High phosphorus (P) loss from agricultural fields has been an environmental concern because of potential water quality problems in streams and lakes. To better understand the process of P loss and evaluate the effects of different phosphorus fertilization rates on phosphorus losses, the USDA Annualized AGricultural Non-Point Source (AnnAGNPS) pollutant loading model was applied to the Ohio Upper Auglaize watershed, located in the southern portion of the Maumee River Basin. In this study, the ...

  6. Interpolating precipitation and its relation to runoff and non-point source pollution.

    Science.gov (United States)

    Chang, Chia-Ling; Lo, Shang-Lien; Yu, Shaw-L

    2005-01-01

    When rainfall spatially varies, complete rainfall data for each region with different rainfall characteristics are very important. Numerous interpolation methods have been developed for estimating unknown spatial characteristics. However, no interpolation method is suitable for all circumstances. In this study, several methods, including the arithmetic average method, the Thiessen Polygons method, the traditional inverse distance method, and the modified inverse distance method, were used to interpolate precipitation. The modified inverse distance method considers not only horizontal distances but also differences between the elevations of the region with no rainfall records and of its surrounding rainfall stations. The results show that when the spatial variation of rainfall is strong, choosing a suitable interpolation method is very important. If the rainfall is uniform, the precipitation estimated using any interpolation method would be quite close to the actual precipitation. When rainfall is heavy in locations with high elevation, the rainfall changes with the elevation. In this situation, the modified inverse distance method is much more effective than any other method discussed herein for estimating the rainfall input for WinVAST to estimate runoff and non-point source pollution (NPSP). When the spatial variation of rainfall is random, regardless of the interpolation method used to yield rainfall input, the estimation errors of runoff and NPSP are large. Moreover, the relationship between the relative error of the predicted runoff and predicted pollutant loading of SS is high. However, the pollutant concentration is affected by both runoff and pollutant export, so the relationship between the relative error of the predicted runoff and the predicted pollutant concentration of SS may be unstable.

  7. Tropospheric Emissions: Monitoring of Pollution (TEMPO)

    Science.gov (United States)

    Chance, Kelly; Liu, Xiong; Suleiman, Raid M.; Flittner, David E.; Al-Saadi, Jassim; Janz, Scott J.

    2014-06-01

    TEMPO, selected by NASA as the first Earth Venture Instrument, will measure atmospheric pollution for greater North America from space using ultraviolet and visible spectroscopy. TEMPO measures from Mexico City to the Canadian oil sands, and from the Atlantic to the Pacific, hourly and at high spatial resolution. TEMPO provides a tropospheric measurement suite that includes the key elements of tropospheric air pollution chemistry. Measurements are from geostationary (GEO) orbit, to capture the inherent high variability in the diurnal cycle of emissions and chemistry. The small product spatial footprint resolves pollution sources at sub-urban scale. Together, this temporal and spatial resolution improves emission inventories, monitors population exposure, and enables effective emission-control strategies. TEMPO takes advantage of a GEO host spacecraft to provide a modest-cost mission that measures the spectra required to retrieve O3, NO2, SO2, H2CO, C2H2O2, H2O, aerosols, cloud parameters, and UVB radiation. TEMPO thus measures the major elements, directly or by proxy, in the tropospheric O3 chemistry cycle. Multi-spectral observations provide sensitivity to O3 in the lowermost troposphere, reducing uncertainty in air quality predictions by 50 %. TEMPO quantifies and tracks the evolution of aerosol loading. It provides near-real-time air quality products that will be made widely, publicly available. TEMPO makes the first tropospheric trace gas measurements from GEO, by building on the heritage of five spectrometers flown in low-earth-orbit (LEO). These LEO instruments measure the needed spectra, although at coarse spatial and temporal resolutions, to the precisions required for TEMPO and use retrieval algorithms developed for them by TEMPO Science Team members and currently running in operational environments. This makes TEMPO an innovative use of a well-proven technique, able to produce a revolutionary data set. TEMPO provides much of the atmospheric measurement

  8. Echinoderms and oil pollution: a potential stress assay using bacterial symbionts

    International Nuclear Information System (INIS)

    Newton, L.C.

    1995-01-01

    Oil pollution is a problem in the North Sea. Important sources of oil pollution are spills and drill cutting. Echinoderms are a major component of the macrobenthos in the North Sea (and elsewhere). They tend to be very sensitive to various types of marine pollution. Many species of echinoderms contain symbiotic sub-cuticular bacteria (SCB). The response of Amphiura filiformis, A. chiajei and Ophiothrix fragilis, all of which contain SCB, to oil pollution was studied in laboratory experiments, mesocosms and in the field. Sublethal stress was monitored by examining changes in the tissue loading of SCB. When subjected to hydrocarbon insult, there was a decline in the number of SCB. The potential use of SCB abundance to detect sublethal stress is discussed. (author)

  9. Pollutant removal-oriented yeast biomass production from high-organic-strength industrial wastewater: A review

    International Nuclear Information System (INIS)

    Yang, Min; Zheng, Shaokui

    2014-01-01

    Microbial single-cell-protein (SCP) production from high-organic-strength industrial wastewaters is considered an attractive method for both wastewater purification and resource utilization. In the last two decades, pollutant removal-oriented yeast SCP production processes, i.e., yeast treatment processes, have attracted a great deal of attention from a variety of research groups worldwide. Different from conventional SCP production processes, yeast treatment processes are characterized by higher pollutant removal rates, lower production costs, highly adaptive yeast isolates from nature, no excess nutrient supplements, and are performed under non-sterile conditions. Furthermore, yeast treatment processes are similar to bacteria-dominated conventional activated sludge processes, which offer more choices for yeast SCP production and industrial wastewater treatment. This review discusses why highly adaptive yeast species isolated from nature are used in the yeast treatment process rather than commercial SCP producers. It also describes the application of yeast treatment processes for treating high-carboxyhydrate, oil-rich and high-salinity industrial wastewater, focusing primarily on high-strength biodegradable organic substances, which usually account for the major fraction of biochemical oxygen demand. Also discussed is the biodegradation of xenobiotics, such as color (including dye and pigment) and toxic substances (including phenols, chlorophenols, polycyclic aromatic hydrocarbons, etc.), present in industrial wastewater. Based on molecular information of yeast community structures and their regulation in yeast treatment systems, we also discuss how to maintain efficient yeast species in yeast biomass and how to control bacterial and mold proliferation in yeast treatment systems. - Highlights: • Pollutant removal-oriented yeast SCP production processes offer more choices. • Highly adaptive yeast isolates replace commercial SCP producers. • Yeasts degrade

  10. Study on characteristics of high frequency dielectric barrier discharge for the removal of organic pollutant adsorbed on activated carbon

    Energy Technology Data Exchange (ETDEWEB)

    Qu, G.Z.; Li, G.F. [Dalian Univ. of Technology, Dalian (China). Inst. of Electrostatics and Special Power; Li, J.; Lu, N.; Wu, Y.; Li, D. [Dalian Univ. of Technology, Dalian (China). Inst. of Electrostatics and Special Power; Key Lab of Industrial Ecology and Environmental Engineering, Ministry of Education, Dalian (China)

    2010-07-01

    Advanced oxidation technologies such as photocatalysis, electrochemical degradation, Fenton oxidation, hydrogen peroxide oxidation, and plasma oxidation are increasingly being used to degrade refractory biodegradable organic contaminants. The plasma oxidation method has the advantage of direct in situ production of multiple types of high-reactive chemical species, including molecules and radicals that facilitate the degradation reaction. In addition, plasma oxidation does not produce any secondary pollution. Compared to other plasma technologies, the dielectric barrier discharge (DBD) plasma has been considered as a promising technology for removing toxic compounds because of its stability and its treatability property of biologically recalcitrant compounds in wastewater. However, the energy efficiency of DBD requires improvement for economic reasons. This paper reported on an experimental study that investigated the electrical characteristics of a parallel plate DBD reactor using a high frequency power supply for the removal of pentachlorophenol (PCP) adsorbed on activated carbon (AC). This study examined the effects of AC with different mass on discharge characteristics and compared the voltage and current waveforms, and discharge images of DBD reactors with different dielectric configurations. When the DBD reactor filled with AC, the applied voltage of discharge decreased regardless of the DBD reactor configuration in terms of having a single barrier or two barriers. The discharge characteristics had no significant change with AC mass increasing. The discharge images and current waveforms showed that DBD reactor configuration consisting of two dielectrics is more homogeneous and stable than the one consisting of a single dielectric. Under the same electric field condition, the degradation efficiency of PCP in two barriers reactor is higher than that in single barrier reactor. It was concluded that the findings from this study may be instrumental in treating

  11. The development of an approach to assess critical loads of acidity for woodland habitats in Great Britain

    Directory of Open Access Journals (Sweden)

    S. J. Langan

    2004-01-01

    Full Text Available Alongside other countries that are signatories to the UNECE Convention Long Range Transboundary on Air Pollution, the UK is committed to reducing the impact of air pollution on the environment. To advise and guide this policy in relation to atmospheric emissions of sulphur and nitrogen, a critical load approach has been developed. To assess the potential impact of these pollutants on woodland habitats a steady state, simple mass balance model has been parameterised. For mineral soils, a Ca:Al ratio in soil solution has been used as the critical load indicator for potential damage. For peat and organic soils critical loads have been set according to a pH criterion. Together these approaches have been used with national datasets to examine the potential scale of acidification in woodland habitats across the UK. The results can be mapped to show the spatial variability in critical loads of the three principal woodland habitat types (managed coniferous, managed broadleaved/ mixed woodland and unmanaged woodland. The results suggest that there is a wide range of critical loads. The most sensitive (lowest critical loads are associated with managed coniferous followed by unmanaged woodland on peat soils. Calculations indicate that at steady state, acid deposition inputs reported for 1995–1997 result in a large proportion of all the woodland habitats identified receiving deposition loads in excess of their critical load; i.e. critical loads are exceeded. These are discussed in relation to future modelled depositions for 2010. Whilst significant widespread negative impacts of such deposition on UK woodland habitats have not been reported, the work serves to illustrate that if acid deposition inputs were maintained and projected emissions reductions not achieved, the long-term sustainability of large areas of woodland in the UK could be compromised. Keywords: critical loads, acid deposition, acidification, woodland, simple mass balance model

  12. Study on the quantitative relationship between Agricultural water and fertilization process and non-point source pollution based on field experiments

    Science.gov (United States)

    Wang, H.; Chen, K.; Wu, Z.; Guan, X.

    2017-12-01

    In recent years, with the prominent of water environment problem and the relative increase of point source pollution governance, especially the agricultural non-point source pollution problem caused by the extensive use of fertilizers and pesticides has become increasingly aroused people's concern and attention. In order to reveal the quantitative relationship between agriculture water and fertilizer and non-point source pollution, on the basis of elm field experiment and combined with agricultural drainage irrigation model, the agricultural irrigation water and the relationship between fertilizer and fertilization scheme and non-point source pollution were analyzed and calculated by field emission intensity index. The results show that the variation of displacement varies greatly under different irrigation conditions. When the irrigation water increased from 22cm to 42cm, the irrigation water increased by 20 cm while the field displacement increased by 11.92 cm, about 66.22% of the added value of irrigation water. Then the irrigation water increased from 42 to 68, irrigation water increased 26 cm, and the field displacement increased by 22.48 cm, accounting for 86.46% of irrigation water. So there is an "inflection point" between the irrigation water amount and field displacement amount. The load intensity increases with the increase of irrigation water and shows a significant power correlation. Under the different irrigation condition, the increase amplitude of load intensity with the increase of irrigation water is different. When the irrigation water is smaller, the load intensity increase relatively less, and when the irrigation water increased to about 42 cm, the load intensity will increase considerably. In addition, there was a positive correlation between the fertilization and load intensity. The load intensity had obvious difference in different fertilization modes even with same fertilization level, in which the fertilizer field unit load intensity

  13. Polluted Alamuyo River: Impacts on surrounding wells, microbial ...

    African Journals Online (AJOL)

    The physicochemical analysis and microbial load of polluted Alamuyo River in Ibadan, Nigeria and selected wells along its course were evaluated. Toxic effects of water samples obtained from upstream (A) and down stream (F) of the river were also evaluated using Allium cepa root assay. The result of the analysis revealed ...

  14. Manufacture of highly loaded silica-supported cobalt Fischer–Tropsch catalysts from a metal organic framework

    KAUST Repository

    Sun, Xiaohui; Suarez, Alma I. Olivos; Meijerink, Mark; van Deelen, Tom; Ould-Chikh, Samy; Zečević, Jovana; de Jong, Krijn P.; Kapteijn, Freek; Gascon, Jorge

    2017-01-01

    The development of synthetic protocols for the preparation of highly loaded metal nanoparticle-supported catalysts has received a great deal of attention over the last few decades. Independently controlling metal loading, nanoparticle size

  15. High Dietary Protein Intake and Protein-Related Acid Load on Bone Health.

    Science.gov (United States)

    Cao, Jay J

    2017-12-01

    Consumption of high-protein diets is increasingly popular due to the benefits of protein on preserving lean mass and controlling appetite and satiety. The paper is to review recent clinical research assessing dietary protein on calcium metabolism and bone health. Epidemiological studies show that long-term, high-protein intake is positively associated with bone mineral density and reduced risk of bone fracture incidence. Short-term interventional studies demonstrate that a high-protein diet does not negatively affect calcium homeostasis. Existing evidence supports that the negative effects of the acid load of protein on urinary calcium excretion are offset by the beneficial skeletal effects of high-protein intake. Future research should focus on the role and the degree of contribution of other dietary and physiological factors, such as intake of fruits and vegetables, in reducing the acid load and further enhancing the anabolic effects of protein on the musculoskeletal system.

  16. Simultaneously Recovering High-Purity Chromium and Removing Organic Pollutants from Tannery Effluent

    Directory of Open Access Journals (Sweden)

    Jie Zong

    2016-01-01

    Full Text Available Chromium pollution is a serious issue because of carcinogenic toxicities of the pollutants and low recovery rate of chromium because of the presence of organic, such as protein and fat. In this work, high recovery rate and high purity of the chromium ion were successfully prepared by the way of acid enzyme, flocculant, and Fenton oxidation. The experiments were characterized by TG, TOC, UV-VIS, and SEM. In the work, the tannery waste chrome liquor was used as experimental material. The results showed that the percentage of reduction of TOC in the tannery waste chrome liquor by method of Fenton oxidation, acid enzyme, and the flocculant was 71.15%, 65.26%, and 22.05%, respectively. Therefore, the organism content of chrome tanning waste liquid was greatly reduced through the pretreatment. And the application experiment showed that the properties and grain surface and fibers of the tanned leather with commercial chromium powder and chrome tanning agent prepared from the chromium waste liquid treated with Fenton are nearly the same.

  17. Compilation, evaluation and assessment of the existing data on the pollution load affecting the water quality of the central stretch of the river Elbe on the basis of uniform common criteria (preliminary study). Vol. 1

    International Nuclear Information System (INIS)

    Guhr, H.; Buettner, O.; Dreyer, U.; Krebs, D.; Spott, D.; Suhr, U.; Weber, E.

    1993-01-01

    The data (concentrations, pollution loads) measured for the 566 km flowing stretch of the river Elbe on the territory of the former GDR were compiled and evaluated according to primary statistical aspects. The longitudinal section was prepared for major variables with regard to the flow for Q50% and Q5%. The distribution of concentration in various measuring points was shown by means of box plots. Interdependencies between concentration and flow as well as water temperature were investigated and used for assessing diffuse matter input. In addition to determining the saprobic index, the biological control of water pollution comprised the assessment of the macrozoobenthos in the area of sewage discharge, chlorophyll measurements, and inventory of the fish population, analysis of pollutant accumulation in fish and in zoobenthos as well as virus detection. The water quality of the river Elbe was evaluated in compliance with the binding E.C. guidelines and national regulations/recommendations revealing an extreme pollution level which impairs or excludes various utilizations of the Elbe water. (orig.) [de

  18. Identification of pollutant sources in a rapidly developing urban river catchment in China

    Science.gov (United States)

    Huang, Jingshui; Yin, Hailong; Jomma, Seifeddine; Rode, Michael; Zhou, Qi

    2016-04-01

    Rapid economic development and urbanization worldwide cause serious ecological and environmental problems. A typical region that is in transition and requires systemic research for effective intervention is the rapidly developing city of Hefei in central P. R. China. In order to investigate the sources of pollutants over a one-year period in Nanfei River catchment that drains the city of Hefei, discharges were measured and water samples were taken and measured along the 14km river section at 10 sites for 4 times from 2013 to 2014. Overflow concentrations of combined sewer and separate storm drains were also measured by selecting 15 rain events in 4 typical drainage systems. Loads and budgets of water and different pollutant sources i.e., wastewater treatment plant (WWTP) effluent, urban drainage overflow, unknown wastewater were calculated. The water balance demonstrated that >70% of the discharge originated from WWTP effluent. Lack of clean upstream inflow thereby is threatening ecological safety and water quality. Furthermore, mass fluxes calculations revealed that >40% of the COD (Chemical Oxygen Demand) loads were from urban drainage overflow because of a large amount of discharge of untreated wastewater in pumping stations during rain events. WWTP effluent was the predominant source of the total nitrogen loads (>60%) and ammonia loads (>45%). However, the total phosphorous loads from three different sources are similar (˜1/3). Thus, our research provided a basis for appropriate and prior mitigation strategies (state-of-art of WWTP upgrade, sewer systems modification, storm water regulation and storage capacity improvement, etc.) for different precedence-controlled pollutants with the limited infrastructure investments in these rapidly developing urban regions.

  19. Particulate matter pollution over a Mediterranean urban area.

    Science.gov (United States)

    Pateraki, St; Assimakopoulos, V D; Maggos, Th; Fameli, K M; Kotroni, V; Vasilakos, Ch

    2013-10-01

    The main purpose of this study is to investigate the aerosols' (PM10, PM2.5, and PM1) spatial and temporal distribution in different types of environment in a Mediterranean urban region, the Greater Athens Area based on data from a sampling campaign that took place during the cold and warm period of 2008. The influence of the atmospheric circulation patterns, the possible local transport mechanisms, as well as the differentiation of the PM behaviour from that of the inorganic pollutants (NOx, O3), are analysed and discussed. Furthermore, the Comprehensive Air Quality Model with extensions (CAMx) was applied for selected sampling dates and its results were evaluated against measurements in order to interpret qualitatively the configured picture of the air pollution above the GAA. Analysis of the measurement data show that local sources such as traffic and industry dominate over the prevailing PM loads, especially at the 'hot spot' areas. Moreover, the synoptic circulation patterns associated with calm conditions and southerly flows lead to high particulate pollution levels that also affect the urban background stations. Saharan dust outbreaks appeared to increase the particles' diameter as well as the number of E.U. limit value exceedances within the stations of our network. Without any dependence on the characteristics of the investigated atmosphere, PM1 always constituted the greatest part of the PM2.5 mass while PM10, especially during the Saharan dust episodes, was mainly constituted by the coarse fraction. The numerical modelling approach of the geographical distribution of PM10, PM2.5, NOx and O3 justified the design of the sampling campaign, indicating the need for the systematic and parallel monitoring and modelling of the pollutants' dispersion in order to understand the particulate pollution problem in the GAA and to aid to the formulation of pollution control strategies. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. A source classification framework supporting pollutant source mapping, pollutant release prediction, transport and load forecasting, and source control planning for urban environments

    DEFF Research Database (Denmark)

    Lützhøft, Hans-Christian Holten; Donner, Erica; Wickman, Tonie

    2012-01-01

    for this purpose. Methods Existing source classification systems were examined by a multidisciplinary research team, and an optimised SCF was developed. The performance and usability of the SCF were tested using a selection of 25 chemicals listed as priority pollutants in Europe. Results The SCF is structured...... in the form of a relational database and incorporates both qualitative and quantitative source classification and release data. The system supports a wide range of pollution monitoring and management applications. The SCF functioned well in the performance test, which also revealed important gaps in priority...

  1. Water Pollution, Teachers' Edition.

    Science.gov (United States)

    Lavaroni, Charles W.; And Others

    One of three in a series about pollution, this teacher's guide for a unit on water pollution is designed for use in junior high school grades. It offers suggestions for extending the information and activities contained in the textual material for students. Chapter 1 discusses the problem of water pollution and involves students in processes of…

  2. Noise Pollution, Teachers' Edition.

    Science.gov (United States)

    O'Donnell, Patrick A.; Lavaroni, Charles W.

    One of three in a series about pollution, this teacher's guide for a unit on noise pollution is designed for use in junior high school grades. It offers suggestions for extending the information and activities contained in the textual material for students. Chapter 1 discusses the problem of noise pollution and involves students in processes of…

  3. Air Pollution Episodes Associated with Prescribed Burns

    Science.gov (United States)

    Hart, M.; Di Virgilio, G.; Jiang, N.

    2017-12-01

    Air pollution events associated with wildfires have been associated with extreme health impacts. Prescribed burns are an important tool to reduce the severity of wildfires. However, if undertaken during unfavourable meteorological conditions, they too have the capacity to trigger extreme air pollution events. The Australian state of New South Wales has increased the annual average area treated by prescribed burn activities by 45%, in order to limit wildfire activity. Prescribed burns need to be undertaken during meteorological conditions that allow the fuel load to burn, while still allowing the burn to remain under control. These conditions are similar to those that inhibit atmospheric dispersion, resulting in a fine balance between managing fire risk and managing ambient air pollution. During prescribed burns, the Sydney air shed can experience elevated particulate matter concentrations, especially fine particulates (PM2.5) that occasionally exceed national air quality standards. Using pollutant and meteorological data from sixteen monitoring stations in Sydney we used generalized additive model and CART analyses to profile the meteorological conditions influencing air quality during planned burns. The insights gained from this study will help improve prescribed burn scheduling in order to reduce the pollution risk to the community, while allowing fire agencies to conduct this important work.

  4. The characterization of secondary lithium-ion battery degradation when operating complex, ultra-high power pulsed loads

    Science.gov (United States)

    Wong, Derek N.

    The US Navy is actively developing all electric fleets, raising serious questions about what is required of onboard power supplies in order to properly power the ship's electrical systems. This is especially relevant when choosing a viable power source to drive high power propulsion and electric weapon systems in addition to the conventional loads deployed aboard these types of vessels. Especially when high pulsed power loads are supplied, the issue of maintaining power quality becomes important and increasingly complex. Conventionally, a vessel's electrical power is generated using gas turbine or diesel driven motor-generator sets that are very inefficient when they are used outside of their most efficient load condition. What this means is that if the generator is not being utilized continuously at its most efficient load capacity, the quality of the output power may also be effected and fall outside of the acceptable power quality limits imposed through military standards. As a solution to this potential problem, the Navy has proposed using electrochemical storage devices since they are able to buffer conventional generators when the load is operating below the generator's most efficient power level or able to efficiently augment a generator when the load is operating in excess of the generator's most efficient power rating. Specifically, the US Navy is interested in using commercial off-the-shelf (COTS) lithium-ion batteries within an intelligently controlled energy storage module that could act as either a prime power supply for on-board pulsed power systems or as a backup generator to other shipboard power systems. Due to the unique load profile of high-rate pulsed power systems, the implementation of lithium-ion batteries within these complex systems requires them to be operated at very high rates and the effects these things have on cell degradation has been an area of focus. There is very little published research into the effects that high power transient

  5. Soil pollution from motor car emissions in the highest region of the Tauern mountains autobahn

    International Nuclear Information System (INIS)

    Kasperowski, E.; Frank, E.

    1990-01-01

    In a pilot study, pollutant loads from motor traffic were investigated and quantified in soils and grassland near the autobahn. Near the motorway, increased concentrations of inorganic and organic pollutants were found, depending on distance, both in soil and in grassland. The decreased soil life is also attributed to this. (orig.) [de

  6. On Hydraulic and Pollution Effects of Converting Combined Sewer Catchments to Separate Sewer Catchments

    DEFF Research Database (Denmark)

    Thorndahl, Søren Liedtke; Schaarup-Jensen, Kjeld; Rasmussen, Michael R.

    2015-01-01

    systems to become serviced with separate sewer systems decreases the volumes of storm water and pollutants diverted to the waste water treatment plant and discharged as combined sewer overflow. This happens at the expense of an increase in volumes of storm water and pollutant loads diverted to local...... receiving waters when detention ponds are not built-in the new separate sewer systems. It is concluded that consequences can be fatal for receiving waters, if no retention of pollutants is integrated into the system....

  7. Dawn song in natural and artificial continuous day: Light pollution affects songbirds at high latitudes.

    Science.gov (United States)

    Derryberry, Elizabeth P

    2017-10-01

    In Focus: Da Silva, A., & Kempenaers, B. (2017). Singing from North to South: Latitudinal variation in timing of dawn singing under natural and artificial light conditions. Journal of Animal Ecology, 86, 1286-1297. doi: 10.1111/1365-2656.12739 Satellite images of the world at night show bright dots connected by glowing lines crisscrossing the globe. As these connect-the-dots become brighter and expand into more and more remote regions, much of the flora and fauna of the world are experiencing evolutionarily unprecedented levels of light at night. Light cues are essential to most physiological and behavioural processes, and so the need to measure the effects of light pollution on these processes is critical. In this issue, Da Silva and Kempenaers take on this task using an important reproductive behaviour in songbirds-dawn song. The geographic, temporal and taxonomic breadth of sampling in this study allows for a close examination of a potentially complex interaction between light pollution and natural variation in the behaviour of dawn singing across latitude, season and species. Their extensive dataset highlights complexity in how songbirds respond to light pollution. Although light pollution has a strong effect on the timing of dawn song, not all songbirds respond the same way to light pollution, and the effects of light pollution vary with changes in natural light levels. Early dawn singers show more flexibility in the timing of dawn song across the season and across latitudes than late dawn singers, and also appear less affected by light pollution at high latitudes than are late dawn singers. These findings suggest that not all songbirds are responding to artificial continuous daylight as they do to natural continuous daylight, highlighting the general need to measure the fitness effects of light pollution. © 2017 The Author. Journal of Animal Ecology © 2017 British Ecological Society.

  8. Cognitive load, emotion, and performance in high-fidelity simulation among beginning nursing students: a pilot study.

    Science.gov (United States)

    Schlairet, Maura C; Schlairet, Timothy James; Sauls, Denise H; Bellflowers, Lois

    2015-03-01

    Establishing the impact of the high-fidelity simulation environment on student performance, as well as identifying factors that could predict learning, would refine simulation outcome expectations among educators. The purpose of this quasi-experimental pilot study was to explore the impact of simulation on emotion and cognitive load among beginning nursing students. Forty baccalaureate nursing students participated in teaching simulations, rated their emotional state and cognitive load, and completed evaluation simulations. Two principal components of emotion were identified representing the pleasant activation and pleasant deactivation components of affect. Mean rating of cognitive load following simulation was high. Linear regression identiffed slight but statistically nonsignificant positive associations between principal components of emotion and cognitive load. Logistic regression identified a negative but statistically nonsignificant effect of cognitive load on assessment performance. Among lower ability students, a more pronounced effect of cognitive load on assessment performance was observed; this also was statistically non-significant. Copyright 2015, SLACK Incorporated.

  9. Method for exciting inductive-resistive loads with high and controllable direct current

    International Nuclear Information System (INIS)

    Hill, H.M. Jr.

    1976-01-01

    The apparatus and method for transmitting dc power to a load circuit by applying a dc voltage from a standard waveform synthesizer to duration modulate a bipolar rectangular wave generator are described. As the amplitude of the dc voltage increases, the widths of the rectangular wave generator output pulses increase, and as the amplitude of the dc voltage decreases, the widths of the rectangular wave generator output pulses decrease. Thus, the waveform synthesizer selectively changes the durations of the rectangular wave generator bipolar output pulses so as to produce a rectangular wave ac carrier that is duration modulated in accordance with and in direct proportion to the voltage amplitude from the synthesizer. Thereupon, by transferring the carrier to the load circuit through an amplifier and a rectifier, the load current also corresponds directly to the voltage amplitude from the synthesizer. To this end, the rectified wave at less than 100 percent duty factor amounts to a doubled frequency direct voltage pulse train for applying a direct current to the load, while the current ripple is minimized by a high L/R in the load circuit. In one embodiment, a power transmitting power amplifier means having a dc power supply is matched to the load circuit through a transformer for current magnification without sacrificing load current duration capability, while negative voltage and current feedback are provided in order to insure good output fidelity. 4 Claims, 18 Drawing Figures

  10. Assessment of the risk of failure of high voltage substations due to environmental conditions and pollution on insulators.

    Science.gov (United States)

    Castillo Sierra, Rafael; Oviedo-Trespalacios, Oscar; Candelo, John E; Soto, Jose D

    2015-07-01

    Pollution on electrical insulators is one of the greatest causes of failure of substations subjected to high levels of salinity and environmental pollution. Considering leakage current as the main indicator of pollution on insulators, this paper focuses on establishing the effect of the environmental conditions on the risk of failure due to pollution on insulators and determining the significant change in the magnitude of the pollution on the insulators during dry and humid periods. Hierarchical segmentation analysis was used to establish the effect of environmental conditions on the risk of failure due to pollution on insulators. The Kruskal-Wallis test was utilized to determine the significant changes in the magnitude of the pollution due to climate periods. An important result was the discovery that leakage current was more common on insulators during dry periods than humid ones. There was also a higher risk of failure due to pollution during dry periods. During the humid period, various temperatures and wind directions produced a small change in the risk of failure. As a technical result, operators of electrical substations can now identify the cause of an increase in risk of failure due to pollution in the area. The research provides a contribution towards the behaviour of the leakage current under conditions similar to those of the Colombian Caribbean coast and how they affect the risk of failure of the substation due to pollution.

  11. POLLUTION OF SHOKARSKI STORMWATER CANAL AND ITS INFLUENCE ON THE QUALITY OF THE VARNA BLACK SEA COASTAL AREA, BULGARIA

    Directory of Open Access Journals (Sweden)

    Anna Simeonova

    2012-03-01

    Full Text Available Pollution of Shokarski stormwater canal and its influence on the quality of the Varna Black Sea coastal area, Bulgaria. In the present study was investigated the pollution of Shokаrski stormwater canal, discharging its water into the Varna Black Sea coastal area. Monitoring was carried out during 2011 year at 5 sites along the canal water flow. The pollution was determined by organoleptic and physico- chemical characteristics, nutrients concentrations and the organic load. Critical levels of dissolved oxygen were measured at some of the monitoring sites ranging from 0,65 to 2,79 mg/dm3. Ammonium and nitrite concentrations were above the threshold limits at all sites. The phosphates’ concentrations varied very dynamically ranging from 0,18 to 11,8 mg/dm3 and in most of the cases exceeded the threshold limit. Very high levels of biochemically degradable organic pollutants were determined with biochemical oxygen demand values reaching- 68,96 mg/dm3. The Shokarski canal pollution could be considered as a tremendous thread for the quality of the Varna Black Sea coastal area, Bulgaria.

  12. The Promoting Role of Different Carbon Allotropes Cocatalysts for Semiconductors in Photocatalytic Energy Generation and Pollutants Degradation

    Directory of Open Access Journals (Sweden)

    Weiwei Han

    2017-10-01

    Full Text Available Semiconductor based photocatalytic process is of great potential for solving the fossil fuels depletion and environmental pollution. Loading cocatalysts for the modification of semiconductors could increase the separation efficiency of the photogenerated hole-electron pairs, enhance the light absorption ability of semiconductors, and thus obtain new composite photocatalysts with high activities. Kinds of carbon allotropes, such as activated carbon, carbon nanotubes, graphene, and carbon quantum dots have been used as effective cocatalysts to enhance the photocatalytic activities of semiconductors, making them widely used for photocatalytic energy generation, and pollutants degradation. This review focuses on the loading of different carbon allotropes as cocatalysts in photocatalysis, and summarizes the recent progress of carbon materials based photocatalysts, including their synthesis methods, the typical applications, and the activity enhancement mechanism. Moreover, the cocatalytic effect among these carbon cocatalysts is also compared for different applications. We believe that our work can provide enriched information to harvest the excellent special properties of carbon materials as a platform to develop more efficient photocatalysts for solar energy utilization.

  13. Linking DMR and TRI Data in the DMR Pollutant Loading Tool ...

    Science.gov (United States)

    ECHO, Enforcement and Compliance History Online, provides compliance and enforcement information for approximately 800,000 EPA-regulated facilities nationwide. ECHO includes permit, inspection, violation, enforcement action, and penalty information about facilities regulated under the Clean Air Act (CAA) Stationary Source Program, Clean Water Act (CWA) National Pollutant Elimination Discharge System (NPDES), and/or Resource Conservation and Recovery Act (RCRA). Information also is provided on surrounding demographics when available.

  14. An attempt to explain strength increase due to high loading rates

    International Nuclear Information System (INIS)

    Eibl, J.; Curbach, M.

    1989-01-01

    Most materials such as steel, concrete, ceramics, polymers, etc. show an increase of strength due to high loading rates. A number of mathematical equations are available to describe this behaviour. Nevertheless the physical reasons for these observations are still unknown. The common behaviour of a number of materials leads to the assumption that at least some explanations are material independent. Due to this reason the results of the research done at the Institute for Concrete Structures in Karlsruhe are presented in this paper to furnish new ideas for the material research due to dynamic loading. (orig.)

  15. Integrating environmental taxes on local air pollutants with fiscal reform in Hungary: simulations with a computable general equilibrium model

    International Nuclear Information System (INIS)

    Morris, Glenn E.; Revesz, Tamas; Zalai, Ernoe; Fucsko, Jozsef

    1999-01-01

    This paper describes the Fiscal Environmental Integration Model (FEIM) and its use to examine the merits of introducing a set of air pollutant emission taxes and stringent abatement requirements based on best commonly available control technology. These environmental protection strategies are examined both independently and in combination. In addition, Hungary has very high VAT, employment, and income tax rates and therefore might receive more than the usual advantage from using environmental tax revenues to reduce other taxes. We therefore also examine the economic and environmental implications of different uses of the revenues generated by the air pollutant emissions taxes. FEIM is a CGE model of the Hungarian economy that includes sectoral air pollution control costs functions and execution options that allow examination of the key policy choices involved. We developed and ran a baseline and seven scenarios with FEIM. The scenarios centered on introduction of environmental load fees (ELF) on emissions of SO 2 , NO x , and particulates and emission abatement requirements (EAR) for these pollutants. (Author)

  16. Premature aging in bone of fish from a highly polluted marine area

    International Nuclear Information System (INIS)

    Scopelliti, Giovanna; Di Leonardo, Rossella; Tramati, Cecilia D.; Mazzola, Antonio; Vizzini, Salvatrice

    2015-01-01

    Highlights: • Crystalline structure of fishbone mineral was defined by XRD and FT-IR analyses. • Expected positive relationship between fish age and bone maturity was not found. • Mineralisation degree was positively related to high concentration of Hg and Cr. • S. porcus and D. annularis showed the highest bone maturity and Hg content. - Abstract: Fish species have attracted considerable interest in studies assessing biological responses to environmental contaminants. In this study, the attention has been focussed on fishbone of selected fish species from a highly polluted marine area, Augusta Bay (Italy, Central Mediterranean) to evaluate if toxicant elements had an effect on the mineralogical structure of bones, although macroscopic deformations were not evident. In particular, an attempt was made to evaluate if bone mineral features, such as crystallinity, mineral maturity and carbonate/phosphate mineral content, determined by XR-Diffraction and FT-IR Spectroscopy, suffered negative effects due to trace element levels in fishbone, detected by ICP-OES. Results confirmed the reliability of the use of diffractometric and spectroscopic techniques to assess the degree of crystallinity and the mineral maturity in fishbone. In addition, in highly polluted areas, Hg and Cr contamination induced a process of premature aging of fishbone, altering its biochemical and mineral contents

  17. 9 Nutrient Load of the Sakumo Lagoon.cdr

    African Journals Online (AJOL)

    Administrator

    nutrients studied, phosphates were the highest in the Sakumo lagoon. The decreasing ... (2008), used nutrient and the trophic status to assess the ... the level of nutrient pollution of the Ramsar site. Materials and ... In assessing the nutrient load, water samples of the .... tidal waves resulting in sea water intrusion may account ...

  18. Seasonal and spatial variation of diffuse (non-point) source zinc pollution in a historically metal mined river catchment, UK

    Energy Technology Data Exchange (ETDEWEB)

    Gozzard, E., E-mail: emgo@ceh.ac.uk [Hydrogeochemical Engineering Research and Outreach Group, School of Civil Engineering and Geosciences, Newcastle University, Newcastle upon Tyne NE1 7RU (United Kingdom); Mayes, W.M., E-mail: W.Mayes@hull.ac.uk [Hydrogeochemical Engineering Research and Outreach Group, School of Civil Engineering and Geosciences, Newcastle University, Newcastle upon Tyne NE1 7RU (United Kingdom); Potter, H.A.B., E-mail: hugh.potter@environment-agency.gov.uk [Environment Agency England and Wales, c/o Institute for Research on Environment and Sustainability, Newcastle University, Newcastle upon Tyne NE1 7RU (United Kingdom); Jarvis, A.P., E-mail: a.p.jarvis@ncl.ac.uk [Hydrogeochemical Engineering Research and Outreach Group, School of Civil Engineering and Geosciences, Newcastle University, Newcastle upon Tyne NE1 7RU (United Kingdom)

    2011-10-15

    Quantifying diffuse sources of pollution is becoming increasingly important when characterising river catchments in entirety - a prerequisite for environmental management. This study examines both low and high flow events, as well as spatial variability, in order to assess point and diffuse components of zinc pollution within the River West Allen catchment, which lies within the northern England lead-zinc Orefield. Zinc levels in the river are elevated under all flow regimes, and are of environmental concern. Diffuse components are of little importance at low flow, with point source mine water discharges dominating instream zinc concentration and load. During higher river flows 90% of the instream zinc load is attributed to diffuse sources, where inputs from resuspension of metal-rich sediments, and groundwater influx are likely to be more dominant. Remediating point mine water discharges should significantly improve water quality at lower flows, but contribution from diffuse sources will continue to elevate zinc flux at higher flows. - Highlights: > Zinc concentrations breach EU quality thresholds under all river flow conditions. > Contributions from point sources dominate instream zinc dynamics in low flow. > Contributions from diffuse sources dominate instream zinc dynamics in high flow. > Important diffuse sources include river-bed sediment resuspension and groundwater influx. > Diffuse sources would still create significant instream pollution, even with point source treatment. - Diffuse zinc sources are an important source of instream contamination to mine-impacted rivers under varying flow conditions.

  19. Two-Stage Crystallizer Design for High Loading of Poorly Water-Soluble Pharmaceuticals in Porous Silica Matrices

    Directory of Open Access Journals (Sweden)

    Leia Dwyer

    2017-05-01

    Full Text Available While porous silica supports have been previously studied as carriers for nanocrystalline forms of poorly water-soluble active pharmaceutical ingredients (APIs, increasing the loading of API in these matrices is of great importance if these carriers are to be used in drug formulations. A dual-stage mixed-suspension, mixed-product removal (MSMPR crystallizer was designed in which the poorly soluble API fenofibrate was loaded into the porous matrices of pore sizes 35 nm–300 nm in the first stage, and then fed to a second stage in which the crystals were further grown in the pores. This resulted in high loadings of over 50 wt % while still producing nanocrystals confined to the pores without the formation of bulk-sized crystals on the surface of the porous silica. The principle was extended to another highly insoluble API, griseofulvin, to improve its loading in porous silica in a benchtop procedure. This work demonstrates a multi-step crystallization principle API in porous silica matrices with loadings high enough to produce final dosage forms of these poorly water-soluble APIs.

  20. Modeling the contribution of point sources and non-point sources to Thachin River water pollution.

    Science.gov (United States)

    Schaffner, Monika; Bader, Hans-Peter; Scheidegger, Ruth

    2009-08-15

    Major rivers in developing and emerging countries suffer increasingly of severe degradation of water quality. The current study uses a mathematical Material Flow Analysis (MMFA) as a complementary approach to address the degradation of river water quality due to nutrient pollution in the Thachin River Basin in Central Thailand. This paper gives an overview of the origins and flow paths of the various point- and non-point pollution sources in the Thachin River Basin (in terms of nitrogen and phosphorus) and quantifies their relative importance within the system. The key parameters influencing the main nutrient flows are determined and possible mitigation measures discussed. The results show that aquaculture (as a point source) and rice farming (as a non-point source) are the key nutrient sources in the Thachin River Basin. Other point sources such as pig farms, households and industries, which were previously cited as the most relevant pollution sources in terms of organic pollution, play less significant roles in comparison. This order of importance shifts when considering the model results for the provincial level. Crosschecks with secondary data and field studies confirm the plausibility of our simulations. Specific nutrient loads for the pollution sources are derived; these can be used for a first broad quantification of nutrient pollution in comparable river basins. Based on an identification of the sensitive model parameters, possible mitigation scenarios are determined and their potential to reduce the nutrient load evaluated. A comparison of simulated nutrient loads with measured nutrient concentrations shows that nutrient retention in the river system may be significant. Sedimentation in the slow flowing surface water network as well as nitrogen emission to the air from the warm oxygen deficient waters are certainly partly responsible, but also wetlands along the river banks could play an important role as nutrient sinks.

  1. Tuning down the hedonic brain: Cognitive load reduces neural responses to high-calorie food pictures in the nucleus accumbens.

    Science.gov (United States)

    van Dillen, Lotte F; van Steenbergen, Henk

    2018-06-01

    The present research examined whether cognitive load modulates the neural processing of appetitive, high-calorie food stimuli. In a functional magnetic resonance imaging (fMRI) study, participants quickly categorized high-calorie and low-calorie food pictures versus object pictures as edible or inedible while they concurrently performed a digit-span task that varied between low and high cognitive load (memorizing six digits vs. one digit). In line with predictions, the digit-span task engaged the dorsolateral prefrontal cortex (DLPFC) when cognitive load was high compared to low. Moreover, exposure to high-calorie compared to low-calorie food pictures led to increased activation in the nucleus accumbens (NAcc), but only when cognitive load was low and not when it was high. In addition, connectivity analyses showed that load altered the functional coupling between NAcc and right DLPFC during presentation of the high-calorie versus low-calorie food pictures. Together, these findings indicate that loading the cognitive system moderates hedonic brain responses to high-calorie food pictures via interactions between NAcc and DLPFC. Our findings are consistent with the putative cognitive nature of food motivation. Implications for future research are discussed.

  2. Long term remediation of highly polluted acid mine drainage: a sustainable approach to restore the environmental quality of the Odiel river basin.

    Science.gov (United States)

    Caraballo, Manuel A; Macías, Francisco; Rötting, Tobias S; Nieto, José Miguel; Ayora, Carlos

    2011-12-01

    During 20 months of proper operation the full scale passive treatment in Mina Esperanza (SW Spain) produced around 100 mg/L of ferric iron in the aeration cascades, removing an average net acidity up to 1500 mg/L as CaCO(3) and not having any significant clogging problem. Complete Al, As, Cd, Cr, Cu, Ti and V removal from the water was accomplished through almost the entire operation time while Fe removal ranged between 170 and 620 mg/L. The system operated at a mean inflow rate of 43 m(3)/day achieving an acid load reduction of 597 g·(m(2) day)(-1), more than 10 times higher than the generally accepted 40 g·(m(2) day)(-1) value commonly used as a passive treatment system designing criteria. The high performance achieved by the passive treatment system at Mina Esperanza demonstrates that this innovative treatment design is a simple, efficient and long lasting remediation option to treat highly polluted acid mine drainage. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Methodology for agricultural and rural NPS pollution in a typical county of the North China Plain

    International Nuclear Information System (INIS)

    Yang Yong; Chen Ying; Zhang Xiaolan; Ongley, Edwin; Zhao Lei

    2012-01-01

    Agricultural non-point source (NPS) pollution has been recently identified by the Chinese government as a major source of aquatic pollution. Methodologies commonly used to make basin-wide or area-wide assessments are problematic and regional distinctions have not been made relative to rainfall and runoff. Using a typical agricultural county in the Hai River basin of the North China Plan we developed methodology to estimate potential load and delivered load for crops (field crops + rice), animal production, rural living and from atmospheric N input. We use scenarios to allow for uncertainty in delivery to estimate the relative roles of different rural forms of pollution. Livestock raising is the major source of NPS pollution. Despite a 75% rural population, rural living contributes almost nothing to surface water pollution. While over-fertilization is typical, nutrient runoff from crops is low. Our results have implications for policies now under development for NPS control in China. - Highlights: ► Provides specific methods guidance for agricultural NPS assessment in China. ► Crops do not contribute significant N and P to watercourses in North China Plain. ► Rural living contributes almost no N and P to watercourses. ► Livestock is the only significant agricultural source of COD, N and P. - We address the methodology for agricultural NPS pollution assessment. We show that livestock, not rural living or crops, is the significant pollutant source.

  4. Identifying the Correlation between Water Quality Data and LOADEST Model Behavior in Annual Sediment Load Estimations

    Directory of Open Access Journals (Sweden)

    Youn Shik Park

    2016-08-01

    Full Text Available Water quality samples are typically collected less frequently than flow since water quality sampling is costly. Load Estimator (LOADEST, provided by the United States Geological Survey, is used to predict water quality concentration (or load on days when flow data are measured so that the water quality data are sufficient for annual pollutant load estimation. However, there is a need to identify water quality data requirements for accurate pollutant load estimation. Measured daily sediment data were collected from 211 streams. Estimated annual sediment loads from LOADEST and subsampled data were compared to the measured annual sediment loads (true load. The means of flow for calibration data were correlated to model behavior. A regression equation was developed to compute the required mean of flow in calibration data to best calibrate the LOADEST regression model coefficients. LOADEST runs were performed to investigate the correlation between the mean flow in calibration data and model behaviors as daily water quality data were subsampled. LOADEST calibration data used sediment concentration data for flows suggested by the regression equation. Using the mean flow calibrated by the regression equation reduced errors in annual sediment load estimation from −39.7% to −10.8% compared to using all available data.

  5. Effects of Brass (Cu3Zn2) as High Thermal Expansion Material on Shrink Disc Performance During High Thermal Loading

    Science.gov (United States)

    Mazlan, MIS; Mohd, SA; Bahar, ND; Aziz, SAA

    2018-03-01

    This research work is focused on shrink disc operation at high temperature. Geometrical and material design selections have been done by taking into consideration the existing shrink disc operating at high temperature condition. The existing shrink disc confronted slip between shaft and shaft sleeve during thermal loading condition. The assessment has been obtained through virtual experiment by using Finite Element Analysis (FEA) -Thermal Transient Stress for 900 seconds with 300 °C of thermal loading. This investigation consists of the current and improved version of shrink disc, where identical geometries and material properties were utilized. High Thermal Expansion (HTE) material has been introduced to overcome the current design of the shrink disc. Brass (Cu3Zn2) has been selected as the HTE material in the improved shrink disc design due to its high thermal expansion properties. The HTE has shown a significant improvement on the total contact area and contact pressure on the shaft and the shaft sleeve. The improved shrink disc embedded with HTE during thermal loading exhibit a minimum of 1244.1 mm2 of the total area on shaft and shaft sleeve which uninfluenced the total contact area at normal condition which is 1254.3 mm2. Meanwhile, the total pressure of improved shrink disc had an increment of 108.1 MPa while existing shrink disc total pressure has lost 17.2 MPa during thermal loading.

  6. Reducing the pollutant load of olive mill wastewater by photocatalytic membranes and monitoring the process using both tyrosinase biosensor and COD test

    Science.gov (United States)

    Martini, Elisabetta; Tomassetti, Mauro; Campanella, Luigi; Fortuna, Antonio

    2013-12-01

    Photocatalytic technique had already been employed in the treatment of olive mill wastewater (OMW) using the photocatalysis in suspension. The coupling of photocatalytic and membrane techniques should result in a very powerful process bringing great innovation to OMW depollution. Despite the potential advantages using these hybrid photoreactors, research on the combined use of photocatalysis and membranes has so far not been sufficiently developed. The present paper describes a study to assess the photocatalytic efficacy of a new ceramic membrane containing titanium dioxide, irradiated by UV light, used to abate the pollutant load of olive mill wastewater. Good results were obtained (more than 90% of the phenol content was removed and the COD decrease was of the order of 46-51 % in 24 h) particularly using the ceramic membrane compared with those offered by analogous catalytic membranes made of metallic or polymeric materials.

  7. Reducing the pollutant load of olive mill wastewater by photocatalytic membranes and monitoring the process using both tyrosinase biosensor and COD test

    Science.gov (United States)

    Martini, Elisabetta; Tomassetti, Mauro; Campanella, Luigi; Fortuna, Antonio

    2013-01-01

    Photocatalytic technique had already been employed in the treatment of olive mill wastewater (OMW) using the photocatalysis in suspension. The coupling of photocatalytic and membrane techniques should result in a very powerful process bringing great innovation to OMW depollution. Despite the potential advantages using these hybrid photoreactors, research on the combined use of photocatalysis and membranes has so far not been sufficiently developed. The present paper describes a study to assess the photocatalytic efficacy of a new ceramic membrane containing titanium dioxide, irradiated by UV light, used to abate the pollutant load of OMW. Good results were obtained (more than 90% of the phenol content was removed and the COD decrease was of the order of 46–51% in 24 h) particularly using the ceramic membrane compared with those offered by analogous catalytic membranes made of metallic or polymeric materials. PMID:24790964

  8. Agrochemical loading in drains and rivers and its connection with pollution in coastal lagoons of the Mexican Pacific.

    Science.gov (United States)

    Arellano-Aguilar, Omar; Betancourt-Lozano, Miguel; Aguilar-Zárate, Gabriela; Ponce de Leon-Hill, Claudia

    2017-06-01

    The state of Sinaloa in Mexico is an industrialized agricultural region with a documented pesticide usage of 700 t year -1 ; which at least 17 of the pesticides are classified as moderately to highly toxic. Pollutants in the water column of rivers and drains are of great concern because the water flows into coastal lagoons and nearshore waters and thereby affects aquatic organisms. This study was done in four municipalities in the state of Sinaloa that produce food intensively. To investigate the link between pollution in the lagoons and their proximity to agricultural sites, water was sampled in three coastal lagoons and in the rivers and drains that flow into them. Seawater from the Gulf of California, 10 km from the coast, was also analyzed. Concentrations of nutrients, organochlorines, and organophosphorus pesticides were determined. Nutrient determination showed an unhealthy environment with N/P ratios of pollution of the coastal lagoon of Pabellones could be traced mainly to the drains from the agricultural sites. Accumulation of OC pesticides was also observed in the Gulf of California. Tests for 22 organophosphates revealed only five (diazinon, disulfoton, methyl parathion, chlorpyrifos, and mevinphos); diazinon was detected at all the sites, although methyl parathion was present at some sites at concentrations one order of magnitude higher than diazinon.

  9. [Performance of Grass Swales for Controlling Pollution of Roadway Runoff in Field Experiments].

    Science.gov (United States)

    Huang, Jun-jie; Shen, Qing-ran; Li, Tian

    2015-06-01

    Two different styles of grass swales were built in new Binhu region of Hefei city to monitor the flux and quality of the influent and effluent water under actual precipitation conditions, in order to evaluate the performance of water quality purification and pollution load control for roadway runoff. The results showed that both of the grass swales could effectively remove the pollutants such as TSS, COD, Pb, Cu, Cd, Zn in roadway runoff; the median EMC removal efficiencies of TSS and COD were 67.1%, 46.7% respectively,for facility I, and the median EMC removal efficiencies of TSS and COD were 78.6%, 58.6% respectively, for facility II; the concentrations of Pb, Cu, Zn in the effluent of facility II could meet the requirements of the surface water quality class V; release of nitrogen and phosphorus occurred in both facilities I and I[ in several rainfall events, mainly in heavy storms; the removal efficiencies of TP in the two grass swales were improved with the increase of influent concentration; the mean removal efficiencies of TP in facilities I and II were 14.7% and 45.4%, respectively; the load control performance of facility II for pollutants such as TSS, COD, TP, TN, NH4+ -N and NO3- -N was better than that of facility I; in the district with poor soil permeability and low ground slope, application of dry swale could achieve better performance in water quality control and pollution load reduction of roadway runoff.

  10. Prediction of China's coal production-environmental pollution based on a hybrid genetic algorithm-system dynamics model

    International Nuclear Information System (INIS)

    Yu Shiwei; Wei Yiming

    2012-01-01

    This paper proposes a hybrid model based on genetic algorithm (GA) and system dynamics (SD) for coal production–environmental pollution load in China. GA has been utilized in the optimization of the parameters of the SD model to reduce implementation subjectivity. The chain of “Economic development–coal demand–coal production–environmental pollution load” of China in 2030 was predicted, and scenarios were analyzed. Results show that: (1) GA performs well in optimizing the parameters of the SD model objectively and in simulating the historical data; (2) The demand for coal energy continuously increases, although the coal intensity has actually decreased because of China's persistent economic development. Furthermore, instead of reaching a turning point by 2030, the environmental pollution load continuously increases each year even under the scenario where coal intensity decreased by 20% and investment in pollution abatement increased by 20%; (3) For abating the amount of “three types of wastes”, reducing the coal intensity is more effective than reducing the polluted production per tonne of coal and increasing investment in pollution control. - Highlights: ► We propos a GA-SD model for China's coal production-pollution prediction. ► Genetic algorithm (GA) can objectively and accurately optimize parameters of system dynamics (SD) model. ► Environmental pollution in China is projected to grow in our scenarios by 2030. ► The mechanism of reducing waste production per tonne of coal mining is more effective than others.

  11. Low Substrate Loading Limits Methanogenesis and Leads to High Coulombic Efficiency in Bioelectrochemical Systems

    Directory of Open Access Journals (Sweden)

    Tom H. J. A. Sleutels

    2016-01-01

    Full Text Available A crucial aspect for the application of bioelectrochemical systems (BESs as a wastewater treatment technology is the efficient oxidation of complex substrates by the bioanode, which is reflected in high Coulombic efficiency (CE. To achieve high CE, it is essential to give a competitive advantage to electrogens over methanogens. Factors that affect CE in bioanodes are, amongst others, the type of wastewater, anode potential, substrate concentration and pH. In this paper, we focus on acetate as a substrate and analyze the competition between methanogens and electrogens from a thermodynamic and kinetic point of view. We reviewed experimental data from earlier studies and propose that low substrate loading in combination with a sufficiently high anode overpotential plays a key-role in achieving high CE. Low substrate loading is a proven strategy against methanogenic activity in large-scale reactors for sulfate reduction. The combination of low substrate loading with sufficiently high overpotential is essential because it results in favorable growth kinetics of electrogens compared to methanogens. To achieve high current density in combination with low substrate concentrations, it is essential to have a high specific anode surface area. New reactor designs with these features are essential for BESs to be successful in wastewater treatment in the future.

  12. Low Substrate Loading Limits Methanogenesis and Leads to High Coulombic Efficiency in Bioelectrochemical Systems

    Science.gov (United States)

    Sleutels, Tom H. J. A.; Molenaar, Sam D.; Heijne, Annemiek Ter; Buisman, Cees J. N.

    2016-01-01

    A crucial aspect for the application of bioelectrochemical systems (BESs) as a wastewater treatment technology is the efficient oxidation of complex substrates by the bioanode, which is reflected in high Coulombic efficiency (CE). To achieve high CE, it is essential to give a competitive advantage to electrogens over methanogens. Factors that affect CE in bioanodes are, amongst others, the type of wastewater, anode potential, substrate concentration and pH. In this paper, we focus on acetate as a substrate and analyze the competition between methanogens and electrogens from a thermodynamic and kinetic point of view. We reviewed experimental data from earlier studies and propose that low substrate loading in combination with a sufficiently high anode overpotential plays a key-role in achieving high CE. Low substrate loading is a proven strategy against methanogenic activity in large-scale reactors for sulfate reduction. The combination of low substrate loading with sufficiently high overpotential is essential because it results in favorable growth kinetics of electrogens compared to methanogens. To achieve high current density in combination with low substrate concentrations, it is essential to have a high specific anode surface area. New reactor designs with these features are essential for BESs to be successful in wastewater treatment in the future. PMID:27681899

  13. Low Substrate Loading Limits Methanogenesis and Leads to High Coulombic Efficiency in Bioelectrochemical Systems.

    Science.gov (United States)

    Sleutels, Tom H J A; Molenaar, Sam D; Heijne, Annemiek Ter; Buisman, Cees J N

    2016-01-05

    A crucial aspect for the application of bioelectrochemical systems (BESs) as a wastewater treatment technology is the efficient oxidation of complex substrates by the bioanode, which is reflected in high Coulombic efficiency (CE). To achieve high CE, it is essential to give a competitive advantage to electrogens over methanogens. Factors that affect CE in bioanodes are, amongst others, the type of wastewater, anode potential, substrate concentration and pH. In this paper, we focus on acetate as a substrate and analyze the competition between methanogens and electrogens from a thermodynamic and kinetic point of view. We reviewed experimental data from earlier studies and propose that low substrate loading in combination with a sufficiently high anode overpotential plays a key-role in achieving high CE. Low substrate loading is a proven strategy against methanogenic activity in large-scale reactors for sulfate reduction. The combination of low substrate loading with sufficiently high overpotential is essential because it results in favorable growth kinetics of electrogens compared to methanogens. To achieve high current density in combination with low substrate concentrations, it is essential to have a high specific anode surface area. New reactor designs with these features are essential for BESs to be successful in wastewater treatment in the future.

  14. Lightweight Potential of Welded High-strength Steel Joints from S700 Under Constant and Variable Amplitude Loading by High-frequency Mechanical Impact (HFMI) Treatment

    OpenAIRE

    Yıldırım, Halid Can; Marquis, Gary; Sonsino, Cetin Morris

    2015-01-01

    Investigations with longitudinal stiffeners of the steel grade S700 under fully-reversed, constant amplitude loading and under variable amplitude loading with a straight-line spectrum show impressive fatigue strength improvement by high-frequency mechanical impact (HFMI) treatment. However, the degree of improvement was for variable amplitude loading lower when compared to constant amplitude loading due to local plasticity which occurs during larger load levels and consequently reduces the be...

  15. A method to analyze “source–sink” structure of non-point source pollution based on remote sensing technology

    International Nuclear Information System (INIS)

    Jiang, Mengzhen; Chen, Haiying; Chen, Qinghui

    2013-01-01

    With the purpose of providing scientific basis for environmental planning about non-point source pollution prevention and control, and improving the pollution regulating efficiency, this paper established the Grid Landscape Contrast Index based on Location-weighted Landscape Contrast Index according to the “source–sink” theory. The spatial distribution of non-point source pollution caused by Jiulongjiang Estuary could be worked out by utilizing high resolution remote sensing images. The results showed that, the area of “source” of nitrogen and phosphorus in Jiulongjiang Estuary was 534.42 km 2 in 2008, and the “sink” was 172.06 km 2 . The “source” of non-point source pollution was distributed mainly over Xiamen island, most of Haicang, east of Jiaomei and river bank of Gangwei and Shima; and the “sink” was distributed over southwest of Xiamen island and west of Shima. Generally speaking, the intensity of “source” gets weaker along with the distance from the seas boundary increase, while “sink” gets stronger. -- Highlights: •We built an index to study the “source–sink” structure of NSP in a space scale. •The Index was applied in Jiulongjiang estuary and got a well result. •The study is beneficial to discern the high load area of non-point source pollution. -- “Source–Sink” Structure of non-point source nitrogen and phosphorus pollution in Jiulongjiang estuary in China was worked out by the Grid Landscape Contrast Index

  16. Seasonal variation of physicochemical factor and fecal pollution in the Hansan-Geojeman area, Korea

    OpenAIRE

    Young Cheol Park; Poong Ho Kim; Yeoun Joong Jung; Ka Jeong Lee; Min Seon Kim; Kyeong Ri Go; Sang Gi Park; Soon Jae Kwon; Ji Hye Yang; Jong Soo Mok

    2016-01-01

    Abstract The seasonal variation of fecal coliforms (FCs) and physicochemical factors was determined in seawaters of the Hansan-Geojeman area, including a designated area for oyster, and in inland pollution sources of its drainage basin. The mean daily loads of FCs in inland pollution sources ranged from 1.2 × 109 to 3.1 × 1011 most probable number (MPN)/day; however, the pollutants could not be reached at the designated area. FC concentrations of seawaters were closely related to season, rain...

  17. Comparative estimation of soil and plant pollution in the impact area of air emissions from an aluminium plant after technogenic load reduction.

    Science.gov (United States)

    Evdokimova, Galina A; Mozgova, Natalya P

    2015-01-01

    The work provides a comparative analysis of changes in soil properties in the last 10-13 years along the pollution gradient of air emissions from Kandalaksha aluminium plant in connection with the reduction of their volume. The content of the priority pollutant fluorine (F) in atmospheric precipitation and in the organic horizon of soil in the plant impact zone significantly decreased in 2011-2013 compared to 2001. The aluminium concentrations reduced only in immediate proximity to the plant (2 km). The fluorine, calcium (Ca) and magnesium (Mg) concentrations are higher in liquid phase compared to solid phase thus these elements can migrated to greater distances from the pollution source (up to 15-20 km). Silicon (Si), aluminium (Al), iron (Fe) and phosphorus (P) can be found only in solid phases and in fall-out within the 5 km. The acidity of soil litter reduced by 2 pH units in the proximity to the plot within the 2 km. The zone of maximum soil contamination decreased from 2.5 km to 1.5 km from the emission source, the zones of heavy and moderate pollution reduced by 5 km in connection with the reduction of pollutant emissions in the plant. A high correlation between the fluorine concentrations in vegetables and litter was found. Higher fluorine concentrations in the soil result in its accumulation in plants. Mosses accumulate fluorine most intensively.

  18. Manufacture of highly loaded silica-supported cobalt Fischer–Tropsch catalysts from a metal organic framework

    KAUST Repository

    Sun, Xiaohui

    2017-11-16

    The development of synthetic protocols for the preparation of highly loaded metal nanoparticle-supported catalysts has received a great deal of attention over the last few decades. Independently controlling metal loading, nanoparticle size, distribution, and accessibility has proven challenging because of the clear interdependence between these crucial performance parameters. Here we present a stepwise methodology that, making use of a cobalt-containing metal organic framework as hard template (ZIF-67), allows addressing this long-standing challenge. Condensation of silica in the Co-metal organic framework pore space followed by pyrolysis and subsequent calcination of these composites renders highly loaded cobalt nanocomposites (~ 50 wt.% Co), with cobalt oxide reducibility in the order of 80% and a good particle dispersion, that exhibit high activity, C5 + selectivity and stability in Fischer-Tropsch synthesis.

  19. High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs

    Science.gov (United States)

    Shimer, Daniel W.; Lange, Arnold C.

    1995-01-01

    A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

  20. High voltage dc--dc converter with dynamic voltage regulation and decoupling during load-generated arcs

    Science.gov (United States)

    Shimer, D.W.; Lange, A.C.

    1995-05-23

    A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 Figs.

  1. Catchment-scale evaluation of pollution potential of urban snow at two residential catchments in southern Finland.

    Science.gov (United States)

    Sillanpää, Nora; Koivusalo, Harri

    2013-01-01

    Despite the crucial role of snow in the hydrological cycle in cold climate conditions, monitoring studies of urban snow quality often lack discussions about the relevance of snow in the catchment-scale runoff management. In this study, measurements of snow quality were conducted at two residential catchments in Espoo, Finland, simultaneously with continuous runoff measurements. The results of the snow quality were used to produce catchment-scale estimates of areal snow mass loads (SML). Based on the results, urbanization reduced areal snow water equivalent but increased pollutant accumulation in snow: SMLs in a medium-density residential catchment were two- to four-fold higher in comparison with a low-density residential catchment. The main sources of pollutants were related to vehicular traffic and road maintenance, but also pet excrement increased concentrations to a high level. Ploughed snow can contain 50% of the areal pollutant mass stored in snow despite its small surface area within a catchment.

  2. Setting limits: Using air pollution thresholds to protect and restore US ecosystems

    Science.gov (United States)

    Fenn, Mark E.; Lambert, Kathleen F.; Blett, Tamara F.; Burns, Douglas A.; Pardo, Linda H.; Lovett, Gary M.; Haeuber, Richard A.; Evers, David C.; Driscoll, Charles T.; Jeffries, Dean S.

    2011-01-01

    More than four decades of research provide unequivocal evidence that sulfur, nitrogen, and mercury pollution have altered, and will continue to alter, our nation's lands and waters. The emission and deposition of air pollutants harm native plants and animals, degrade water quality, affect forest productivity, and are damaging to human health. Many air quality policies limit emissions at the source but these control measures do not always consider ecosystem impacts. Air pollution thresholds at which ecological effects are observed, such as critical loads, are effective tools for assessing the impacts of air pollution on essential ecosystem services and for informing public policy. U.S. ecosystems can be more effectively protected and restored by using a combination of emissions-based approaches and science-based thresholds of ecosystem damage.

  3. The effect of nitrogen additions on bracken fern and its insect herbivores at sites with high and low atmospheric pollution

    Science.gov (United States)

    M.E. Jones; M.E. Fenn; T.D. Paine

    2011-01-01

    The impact of atmospheric pollution, including nitrogen deposition, on bracken fern herbivores has never been studied. Bracken fern is globally distributed and has a high potential to accumulate nitrogen in plant tissue. We examined the response of bracken fern and its herbivores to N fertilization at a high and low pollution site in forests downwind of Los Angeles,...

  4. [Nitrogen non-point source pollution identification based on ArcSWAT in Changle River].

    Science.gov (United States)

    Deng, Ou-Ping; Sun, Si-Yang; Lü, Jun

    2013-04-01

    The ArcSWAT (Soil and Water Assessment Tool) model was adopted for Non-point source (NPS) nitrogen pollution modeling and nitrogen source apportionment for the Changle River watershed, a typical agricultural watershed in Southeast China. Water quality and hydrological parameters were monitored, and the watershed natural conditions (including soil, climate, land use, etc) and pollution sources information were also investigated and collected for SWAT database. The ArcSWAT model was established in the Changle River after the calibrating and validating procedures of the model parameters. Based on the validated SWAT model, the contributions of different nitrogen sources to river TN loading were quantified, and spatial-temporal distributions of NPS nitrogen export to rivers were addressed. The results showed that in the Changle River watershed, Nitrogen fertilizer, nitrogen air deposition and nitrogen soil pool were the prominent pollution sources, which contributed 35%, 32% and 25% to the river TN loading, respectively. There were spatial-temporal variations in the critical sources for NPS TN export to the river. Natural sources, such as soil nitrogen pool and atmospheric nitrogen deposition, should be targeted as the critical sources for river TN pollution during the rainy seasons. Chemical nitrogen fertilizer application should be targeted as the critical sources for river TN pollution during the crop growing season. Chemical nitrogen fertilizer application, soil nitrogen pool and atmospheric nitrogen deposition were the main sources for TN exported from the garden plot, forest and residential land, respectively. However, they were the main sources for TN exported both from the upland and paddy field. These results revealed that NPS pollution controlling rules should focus on the spatio-temporal distribution of NPS pollution sources.

  5. Hydraulic loading, stability and water quality of Nakivubo wetland ...

    African Journals Online (AJOL)

    Nakivubo wetland, which has performed tertiary water treatment for Kampala city for the past 40 years, is ecologically stressed by agricultural and infrastructural developments. Field studies were carried out to assess the hydraulic loading, pollution profile, stability and water quality of this wetland. The upper and lower ...

  6. Analysis of the Effect of Loading Process on Tribological System Properties

    Directory of Open Access Journals (Sweden)

    Radoslav Majdan

    2016-01-01

    Full Text Available The effect of loading on the properties of selected sliding pair is monitored and analysed in the submitted contribution. The obtained results of dynamic loading were also compared with static loading. The experimental tests were performed using the testing machine Tribotestor M10. Steel 11 600 was selected as a material sample for the shaft as it belongs to commonly used materials in the manufacturing of agricultural components of shaft type or pin type. A full-bronze centrifugally moulded bearing shell from the material CuSn12 was selected as the second element of friction pair. Two oils were selected for lubrication of friction node – the mineral gear oil Madit PP80 and ecological oil Plantohyd 46 S. The selected friction pairs were tested in three loading regimes according to the methodology (two dynamic processes and one static process. 60 tribological tests were performed, i.e. 10 for each type of loading and lubrication. The weight losses of the friction pair elements were part of the tracked and analysed parameters. The polluted oil was examined using the ferrographic analysis to verify the weight losses. The abrasion particles of friction pair and their contribution to oil pollution were also analysed. Following the performed experiments different effects of loading regimes may be concluded, essentially in terms of wear size and the number and size of wear particles as well. The obtained results confirmed that the power spectral density of generated signal is probably an important criterion for assessment in terms of simulated random dynamic load in given experiment. In terms of technical application in loading processes – power spectral density is actually the amount of energy supplied to the process.

  7. Assessment of Gearbox Operational Loads and Reliability under High Mean Wind Speeds

    OpenAIRE

    Dabrowski, Dariusz; Natarajan, Anand

    2015-01-01

    This paper investigates the dynamic loads occurring in the drivetrain of wind turbines with a focus on offshore applications. Herein a model of the gearbox of the 5 MW wind turbine is presented. The model is developed in a multi-body framework using commercial software MSC ADAMS. Validation of the model was based on the experimental data provided by NREL for 750 kW prototype gearbox. Failures of gearboxes caused by high dynamic loads have a significant influence on the cost of operation of wi...

  8. High power RF performance test of an improved SiC load

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, W.H.; Kim, S.H.; Park, Y.J. [Pohang Accelerator Lab., Pohang Inst. of Sceince and Technology, Pohang (KR)] [and others

    1998-11-01

    Two prototypes of SiC loads sustaining a maximum peak power of 50 MW were fabricated by Nihon Koshuha Co. in Japan. The PAL conducted the high power RF performance tests of SiC loads to verify the operation characteristics for the application to the PLS Linac. The in-situ facility for the K 12 module was used for the test, which consists of a modulator and klystron system, waveguide network, vacuum and cooling system, and RF analyzing equipment. As the test results, no breakdown appeared up to 50 MW peak power of 1 {mu}s pulse width at a repetition rate of 50 Hz. However, as the peak power increased above 20 MW at 4 {mu}s with 10 Hz, the breakdown phenomena has been observed. Analysing the test results with the current operation power level of PLS Linac, it is confirmed that the SiC loads well satisfy the criteria of the PLS Linac operation. (author)

  9. City housing atmospheric pollutant impact on emergency visit for asthma: A classification and regression tree approach.

    Science.gov (United States)

    Mazenq, Julie; Dubus, Jean-Christophe; Gaudart, Jean; Charpin, Denis; Viudes, Gilles; Noel, Guilhem

    2017-11-01

    Particulate matter, nitrogen dioxide (NO 2 ) and ozone are recognized as the three pollutants that most significantly affect human health. Asthma is a multifactorial disease. However, the place of residence has rarely been investigated. We compared the impact of air pollution, measured near patients' homes, on emergency department (ED) visits for asthma or trauma (controls) within the Provence-Alpes-Côte-d'Azur region. Variables were selected using classification and regression trees on asthmatic and control population, 3-99 years, visiting ED from January 1 to December 31, 2013. Then in a nested case control study, randomization was based on the day of ED visit and on defined age groups. Pollution, meteorological, pollens and viral data measured that day were linked to the patient's ZIP code. A total of 794,884 visits were reported including 6250 for asthma and 278,192 for trauma. Factors associated with an excess risk of emergency visit for asthma included short-term exposure to NO 2 , female gender, high viral load and a combination of low temperature and high humidity. Short-term exposures to high NO 2 concentrations, as assessed close to the homes of the patients, were significantly associated with asthma-related ED visits in children and adults. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. In-situ investigations of structural changes during cyclic loading by high resolution reciprocal space mapping

    DEFF Research Database (Denmark)

    Diederichs, Annika M.; Thiel, Felix; Lienert, Ulrich

    2017-01-01

    dislocation structures can be identified using advanced electron microscopy and synchrotron techniques. A detailed characterization of the microstructure during cyclic loading by in-situ monitoring the internal structure within individual grains with high energy x-rays can help to understand and predict...... the materials behavior during cyclic deformation and to improve the material design. While monitoring macroscopic stress and strain during cyclic loading, reciprocal space maps of diffraction peaks from single grains are obtained with high resolution. High Resolution Reciprocal Space Mapping was applied...

  11. The Siberian High and Arctic Sea Ice: Long-term Climate Change and Impacts on Air Pollution during Wintertime in China

    Science.gov (United States)

    Long, X.; Zhao, S.; Feng, T.; Tie, X.; Li, G.

    2017-12-01

    China has undergone severe air pollution during wintertime as national industrialization and urbanization have been increasingly developed in the past three decades. It has been suggested that high emission and adverse weather patterns contribute to wintertime air pollution. Recent studies propose that climate change and Arctic sea ice loss likely lead to extreme haze events in winter. Here we use two reanalysis and observational datasets to present the trends of Siberian High (SH) intensity over Eurasia, and Arctic temperature and sea ice. The results show the Arctic region of Asia is becoming warming accompanied by a rapid decline of sea ice while Eurasia is cooling and SH intensity is gradually enhancing. Wind patterns induced by these changes cause straight westerly prevailing over Eurasia at the year of weak SH while strengthened northerly winds at the year of strong SH. Therefore, we utilize regional dynamical and chemical WRF-Chem model to determine the impact of SH intensity difference on wintertime air pollution in China. As a result, enhancing northerly winds at the year of strong SH rapidly dilute and transport air pollution, causing a decline of 50 - 400 µg m-3 PM2.5 concentrations relative to that at the year of weak SH. We also assess the impact of emission reduction to half the current level on air pollution. The results show that emission reduction by 50% has an equivalent impact as the variability of SH intensity. This suggests that climate change over Eurasia has largely offset the negative impact of emission on air pollution and it is urgently needed to take measures to mitigate air pollution. In view of current high emission scenario in China, it will be a long way to effectively mitigate, or ultimately prevent wintertime air pollution.

  12. Simulation of plasma loading of high-pressure RF cavities

    Energy Technology Data Exchange (ETDEWEB)

    Yu, K. [Brookhaven National Lab. (BNL), Upton, NY (United States). Computational Science Initiative; Samulyak, R. [Brookhaven National Lab. (BNL), Upton, NY (United States). Computational Science Initiative; Stony Brook Univ., NY (United States). Dept. of Applied Mathematics and Statistics; Yonehara, K. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Freemire, B. [Northern Illinois Univ., DeKalb, IL (United States)

    2018-01-11

    Muon beam-induced plasma loading of radio-frequency (RF) cavities filled with high pressure hydrogen gas with 1% dry air dopant has been studied via numerical simulations. The electromagnetic code SPACE, that resolves relevant atomic physics processes, including ionization by the muon beam, electron attachment to dopant molecules, and electron-ion and ion-ion recombination, has been used. Simulations studies have also been performed in the range of parameters typical for practical muon cooling channels.

  13. Simulation of plasma loading of high-pressure RF cavities

    Science.gov (United States)

    Yu, K.; Samulyak, R.; Yonehara, K.; Freemire, B.

    2018-01-01

    Muon beam-induced plasma loading of radio-frequency (RF) cavities filled with high pressure hydrogen gas with 1% dry air dopant has been studied via numerical simulations. The electromagnetic code SPACE, that resolves relevant atomic physics processes, including ionization by the muon beam, electron attachment to dopant molecules, and electron-ion and ion-ion recombination, has been used. Simulations studies have been performed in the range of parameters typical for practical muon cooling channels.

  14. Factors affecting metal and radionuclide pollution in the Baltic sea

    Directory of Open Access Journals (Sweden)

    Martin Lodenius

    2016-12-01

    Full Text Available External pollution load in the Baltic Sea originates from urban, agricultural and industrial sources. Emissions of heavy metals have decreased substantially in the catchment area but the temporal trends are not always significant and differ with sample, area and pollutant. The most significant source of anthropogenic radioactivity in the Baltic Sea is fallout from the Chernobyl accident in 1986. Many factors affect the future development of pollutant concentrations including anthropogenic emissions, political decisions and changes in salinity, temperature and water currents, in eutrophication and oxygen status, in fisheries and in atmospheric deposition of pollutants. Large scale changes like eutrophication and climate change affect ecosystems in many ways, directly and indirectly, causing biological and abiotic effects. These factors are interrelated and difficult to predict. Measures aiming to enhance the ecological status of the Baltic Sea will certainly give positive results but this will take at least several decades.

  15. Assessment of Cd, Cr and Pb Pollution in Sediment and Water of Gheshlagh River, Iran, in September 2013

    Directory of Open Access Journals (Sweden)

    Farshid Majnoni

    2015-03-01

    Full Text Available Background: This study aimed to evaluate the pollution levels of surface water with heavy metals including Pb, Cd and Cr in Gheshlagh River, western Iran. Methods: Water and sediment were sampled in five monitoring stations with three replicates in time along the river. The concentration of Cr, Pb and Cd in both water and sediment samples were measured with graphite furnace atomic absorption spectrometer (Australia, Varian 220. The Geoaccumulation Index and Pollution Load Index were employed to assess the pollution level of sediments with heavy metals. Results: The mean value of Cd, Cr, Pb in sediment samples were 0.69, 17.19 and 10.69 µgg-1 per dry weight, respectively. Water samples contained Cd, Cr and Pb concentration of 1.99, 1.45 and 12.92 µgL-1, respectively. The Geoaccumulation Index and Pollution Load Index indicates that the sediments were not polluted with Pb and Cr, and unpolluted to moderately contaminated with Cd in Gheshlagh River. Conclusion: This study concludes that the Gheshlagh River is threatened by heavy metals particularly Cd and Pb.

  16. High Incidence of Breast Cancer in Light-Polluted Areas with Spatial Effects in Korea.

    Science.gov (United States)

    Kim, Yun Jeong; Park, Man Sik; Lee, Eunil; Choi, Jae Wook

    2016-01-01

    We have reported a high prevalence of breast cancer in light-polluted areas in Korea. However, it is necessary to analyze the spatial effects of light polluted areas on breast cancer because light pollution levels are correlated with region proximity to central urbanized areas in studied cities. In this study, we applied a spatial regression method (an intrinsic conditional autoregressive [iCAR] model) to analyze the relationship between the incidence of breast cancer and artificial light at night (ALAN) levels in 25 regions including central city, urbanized, and rural areas. By Poisson regression analysis, there was a significant correlation between ALAN, alcohol consumption rates, and the incidence of breast cancer. We also found significant spatial effects between ALAN and the incidence of breast cancer, with an increase in the deviance information criterion (DIC) from 374.3 to 348.6 and an increase in R2 from 0.574 to 0.667. Therefore, spatial analysis (an iCAR model) is more appropriate for assessing ALAN effects on breast cancer. To our knowledge, this study is the first to show spatial effects of light pollution on breast cancer, despite the limitations of an ecological study. We suggest that a decrease in ALAN could reduce breast cancer more than expected because of spatial effects.

  17. EMISSION OF POLLUTANTS FROM COMBINED SEWER OVERFLOWS IN THE ASPECT OF THEIR IMPACT ON A RECEIVER

    Directory of Open Access Journals (Sweden)

    Agnieszka Brzezińska

    2016-06-01

    Full Text Available Increased efficiency of wastewater treatment highlights the role of combined sewer overflows in deterioration the quality of water receiver because pollutant loads discharged by them have a growing share in entire load discharged into a receiver. The article contains the results of the wastewater quality analyzes emitted into the receiver from the three studied combined sewer overflows of the city of Lodz. The results demonstrated a large variations in the pollutant concentration directed to the receiver during rain events. The possible impact of untreated wastewater emitted to the receiver is also presented. Apart from the pollution of the receiver, mainly by organic and nutrient substances, the microbiological contamination which is dangerous for people using the river as a recreation area and for animals that use a water receiver as a source of drinking water, should be taken into particular attention.

  18. Working Memory Load and Reminder Effect on Event-Based Prospective Memory of High- and Low-Achieving Students in Math.

    Science.gov (United States)

    Chen, Youzhen; Lian, Rong; Yang, Lixian; Liu, Jianrong; Meng, Yingfang

    The effects of working memory (WM) demand and reminders on an event-based prospective memory (PM) task were compared between students with low and high achievement in math. WM load (1- and 2-back tasks) was manipulated as a within-subject factor and reminder (with or without reminder) as a between-subject factor. Results showed that high-achieving students outperformed low-achieving students on all PM and n-back tasks. Use of a reminder improved PM performance and thus reduced prospective interference; the performance of ongoing tasks also improved for all students. Both PM and n-back performances in low WM load were better than in high WM load. High WM load had more influence on low-achieving students than on high-achieving students. Results suggest that low-achieving students in math were weak at PM and influenced more by high WM load. Thus, it is important to train these students to set up an obvious reminder for their PM and improve their WM.

  19. Future residential loads profiles : scenario-based analysis of high penetration of heavy loads and distributed generation

    NARCIS (Netherlands)

    Asare-Bediako, B.; Kling, W.L.; Ribeiro, P.F.

    2014-01-01

    Electric load profiles are useful for accurate load forecasting, network planning and optimal generation capacity. They represent electricity demand patterns and are to a large extent predictable. However, new and heavier loads (heat pumps and electric vehicles), distributed generation, and home

  20. Experimental investigation of bond strength under high loading rates

    Directory of Open Access Journals (Sweden)

    Michal Mathias

    2015-01-01

    Full Text Available The structural behaviour of reinforced concrete is governed significantly by the transmission of forces between steel and concrete. The bond is of special importance for the overlapping joint and anchoring of the reinforcement, where rigid bond is required. It also plays an important role in the rotational capacity of plastic hinges, where a ductile bond behaviour is preferable. Similar to the mechanical properties of concrete and steel also the characteristics of their interaction changes with the velocity of the applied loading. For smooth steel bars with its main bond mechanisms of adhesion and friction, nearly no influence of loading rate is reported in literature. In contrast, a high rate dependence can be found for the nowadays mainly used deformed bars. For mechanical interlock, where ribs of the reinforcing steel are bracing concrete material surrounding the bar, one reason can be assumed to be in direct connection with the increase of concrete compressive strength. For splitting failure of bond, characterized by the concrete tensile strength, an even higher dynamic increase is observed. For the design of Structures exposed to blast or impact loading the knowledge of a rate dependent bond stress-slip relationship is required to consider safety and economical aspects at the same time. The bond behaviour of reinforced concrete has been investigated with different experimental methods at the University of the Bundeswehr Munich (UniBw and the Joint Research Centre (JRC in Ispra. Both static and dynamic tests have been carried out, where innovative experimental apparatuses have been used. The bond stress-slip relationship and maximum pull-out-forces for varying diameter of the bar, concrete compressive strength and loading rates have been obtained. It is expected that these experimental results will contribute to a better understanding of the rate dependent bond behaviour and will serve for calibration of numerical models.

  1. Nonlinear behaviors of FRP-wrapped tall trees subjected to high wind loads

    Science.gov (United States)

    Kang, J.; Yi, Z. Z.; Choi, S. G.

    2017-12-01

    This study investigated the mechanical stability of historical tall trees wrapped with fiber-reinforced polymer (FRP) laminates using finite element (FE) analysis. High wind loads are considered as external loading conditions as they are one of the major threats on the structural stability of tall old trees. There have been several traditional practices to enhance the stability of tall trees exposed to high windstorms such as tree supporters and anchorages. They, however, have been sometimes causing negative effects with their misuses as the application guidelines for those methods were not adequately studied or documented. Furthermore, the oldest known trees in the country should be protected from the damage of external surface as well as ruin of the landscape. The objective of this study was to evaluate the structural effects of FRP wraps applied to tall trees subjected to high wind loads. The anisotropic material properties of wood and FRP laminates were considered in the analysis in addition to geometrically nonlinear behaviors. This study revealed that FRP wrapping for tall trees could effectively reduce the deflections and maximum stresses of trees, which results in the enhanced stability of tall trees. The optimum geometry and thicknesses of FRP wraps proposed in this study would provide fundemental guidelines for designing and constructing the application of innovative FRP wraps on tall trees, which are structurally unstable or should be preserved nationally and historically.

  2. Impact of Acidification on Pollutants Fate and Soil Filtration Function

    Directory of Open Access Journals (Sweden)

    Jarmila Makovniková

    2014-12-01

    Full Text Available The objective of this paper was to investigate the effects of simulated acid load on the fate of inorganic pollutants (Cd, Pb, soil sorption potential, soil filtration func-tion. We made use of a short-term acidification pot experiment with grown plant of spring barley cultivated at 4 different soil types (Fluvisol, Cambisol, Stagnosol, Podzol. The potential of soil filtration was evaluated according to the Eq.: [Soil filtration function]=[Potential of soil sorbents]+[Potential of total content of inor-ganic pollutants]. Potential of soil sorbents (PSS is defined by qualitative (pH, or-ganic matter quality - A400/600 and quantitative factors (carbon content-Cox, humus layer thickness-H according to the Eq.:[PSS]=F(pH+F(A465/665+F(Cox*F(H. Acid load significantly influenced soil sorption potential and thus affected increase in Cd and Pb mobility what was reflected in their transfer into the plants. Results of soil filtration function showed significant change of filtration function in Cambisol.

  3. Hybrid Robust Control Law with Disturbance Observer for High-Frequency Response Electro-Hydraulic Servo Loading System

    Directory of Open Access Journals (Sweden)

    Zhiqing Sheng

    2016-04-01

    Full Text Available Addressing the simulating issue of the helicopter-manipulating booster aerodynamic load with high-frequency dynamic load superimposed on a large static load, this paper studies the design of the robust controller for the electro-hydraulic loading system to realize the simulation of this kind of load. Firstly, the equivalent linear model of the electro-hydraulic loading system under assumed parameter uncertainty is established. Then, a hybrid control scheme is proposed for the loading system. This control scheme consists of a constant velocity feed-forward compensator, a robust inner loop compensator based on disturbance observer and a robust outer loop feedback controller. The constant velocity compensator eliminates most of the extraneous force at first, and then the double-loop cascade composition control strategy is employed to design the compensated system. The disturbance observer–based inner loop compensator further restrains the disturbances including the remaining extraneous force, and makes the actual plant tracking a nominal model approximately in a certain frequency range. The robust outer loop controller achieves the desired force-tracking performance, and guarantees system robustness in the high frequency region. The optimized low-pass filter Q(s is designed by using the H∞ mixed sensitivity optimization method. The simulation results show that the proposed hybrid control scheme and controller can effectively suppress the extraneous force and improve the robustness of the electro-hydraulic loading system.

  4. Statistical examination of the aerosols loading over Mubi-Nigeria: The satellite oobservation analysis

    Directory of Open Access Journals (Sweden)

    Emetere Moses Eterigho

    2016-01-01

    Full Text Available The problem of underestimating or overestimating the aerosols loading over Mubi is inevitable because of the absence of ground stations over the region. Aerosols pollution is a global challenge to life forms as it affects human health, agricultural produce, thermal comfort and weather. The modulation between high and low thermal comforts over Mubi is quite disturbing. The aim of the research is to seek a more reliable approach to estimate the aerosols loading and retention over Mubi. Thirteen years aerosol optical depth (AOD data was obtained from the Multi-angle imaging spectroradiometer (MISR. Mubi is located on latitude 10.27oN and longitude 13.27oE. Statistical tools, as well as analytically derived model for aerosols loading were used to obtain the aerosols retention and loading over the area. It was discovered that the highest aerosols retention over Mubi is 12.7%. The atmospheric constants and tuning constants over Mubi were documented as 0.67 and 0.71 respectively. Due to the volume of aerosols over Mubi, it is necessary to change the International Telecommunication Union (ITU model which relates to signal budgeting.

  5. Environmental pollution and kidney diseases.

    Science.gov (United States)

    Xu, Xin; Nie, Sheng; Ding, Hanying; Hou, Fan Fan

    2018-05-01

    The burden of disease and death attributable to environmental pollution is becoming a public health challenge worldwide, especially in developing countries. The kidney is vulnerable to environmental pollutants because most environmental toxins are concentrated by the kidney during filtration. Given the high mortality and morbidity of kidney disease, environmental risk factors and their effect on kidney disease need to be identified. In this Review, we highlight epidemiological evidence for the association between kidney disease and environmental pollutants, including air pollution, heavy metal pollution and other environmental risk factors. We discuss the potential biological mechanisms that link exposure to environmental pollutants to kidney damage and emphasize the contribution of environmental pollution to kidney disease. Regulatory efforts should be made to control environmental pollution and limit individual exposure to preventable or avoidable environmental risk. Population studies with accurate quantification of environmental exposure in polluted regions, particularly in developing countries, might aid our understanding of the dose-response relationship between pollutants and kidney diseases.

  6. High-uranium-loaded U3O8--Al fuel element development program

    International Nuclear Information System (INIS)

    Martin, M.M.

    1978-01-01

    The High-Uranium-Loaded U 3 O 8 --Al Fuel Development Program supports Argonne National Laboratory efforts to develop high-uranium-density research and test reactor fuel to accommodate use of low-uranium enrichment. The goal is to fuel most research and test reactors with uranium of less than 20% enrichment for the purpose of lowering the potential for diversion of highly-enriched material for nonpeaceful usages

  7. Contemporary and historical trace metal loadings to the sediments of four lakes of the Lake Washington drainage. Completion report

    International Nuclear Information System (INIS)

    Spyridakis, D.E.; Barnes, R.S.

    1978-01-01

    Contemporary and historical loadings of lead, zinc, and copper to the profundal sediments of Lakes Washington, Sammamish, Chester Morse, and Findley were determined using chemical analysis and 210 Pb dating of sediment cores. Elemental sedimentation rates, a cross product of the sedimentation rate, and sediment concentration of a given element, were corrected for natural background concentrations and rates, and extrapolated across established sediment accumulating areas to give a conservative estimate of the pollutional trace metal loadings to each lake. The resulting chronological loadings appeared consistent with the known cultural history of the individual watersheds. Substantial alterations in sedimentation rates were noted in all lakes where deforestation, road building, suburbanization or urbanization had occurred in the lake's watershed. The quantities, elemental ratios and pollutional histories of copper, lead and zinc in the lake sediments indicate that aeolian inputs are the dominant source of trace metal pollution to the lake sediments at the present time

  8. Development of a Web-Based L-THIA 2012 Direct Runoff and Pollutant Auto-Calibration Module Using a Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Chunhwa Jang

    2013-11-01

    Full Text Available The Long-Term Hydrology Impact Assessment (L-THIA model has been used as a screening evaluation tool in assessing not only urbanization, but also land-use changes on hydrology in many countries. However, L-THIA has limitations due to the number of available land-use data that can represent a watershed and the land surface complexity causing uncertainties in manually calibrating various input parameters of L-THIA. Thus, we modified the L-THIA model so that could use various (twenty three land-use categories by considering various hydrologic responses and nonpoint source (NPS pollutant loads. Then, we developed a web-based auto-calibration module by integrating a Genetic-Algorithm (GA into the L-THIA 2012 that can automatically calibrate Curve Numbers (CNs for direct runoff estimations. Based on the optimized CNs and Even Mean Concentrations (EMCs, our approach calibrated surface runoff and nonpoint source (NPS pollution loads by minimizing the differences between the observed and simulated data. Here, we used default EMCs of biochemical oxygen demand (BOD, total nitrogen (TN, and total phosphorus-TP (as the default values to L-THIA collected at various local regions in South Korea corresponding to the classifications of different rainfall intensities and land use for improving predicted NPS pollutions. For assessing the model performance, the Yeoju-Gun and Icheon-Si sites in South Korea were selected. The calibrated runoff and NPS (BOD, TN, and TP pollutions matched the observations with the correlation (R2: 0.908 for runoff and R2: 0.882–0.981 for NPS and Nash-Sutcliffe Efficiency (NSE: 0.794 for runoff and NSE: 0.882–0.981 for NPS for the sites. We also compared the NPS pollution differences between the calibrated and averaged (default EMCs. The calibrated TN and TP (only for Yeoju-Gun EMCs-based pollution loads identified well with the measured data at the study sites, but the BOD loads with the averaged EMCs were slightly better than

  9. DM100 AND DM1200 MELTER TESTING WITH HIGH WASTE LOADING GLASS FORMULATIONS FOR HANFORD HIGH-ALUMINUM HLW STREAMS

    Energy Technology Data Exchange (ETDEWEB)

    KRUGER AA; MATLACK KS; KOT WK; PEGG IL; JOSEPH I

    2009-12-30

    This Test Plan describes work to support the development and testing of high waste loading glass formulations that achieve high glass melting rates for Hanford high aluminum high level waste (HLW). In particular, the present testing is designed to evaluate the effect of using low activity waste (LAW) waste streams as a source of sodium in place ofchemical additives, sugar or cellulose as a reductant, boehmite as an aluminum source, and further enhancements to waste processing rate while meeting all processing and product quality requirements. The work will include preparation and characterization of crucible melts in support of subsequent DuraMelter 100 (DM 100) tests designed to examine the effects of enhanced glass formulations, glass processing temperature, incorporation of the LAW waste stream as a sodium source, type of organic reductant, and feed solids content on waste processing rate and product quality. Also included is a confirmatory test on the HLW Pilot Melter (DM1200) with a composition selected from those tested on the DM100. This work builds on previous work performed at the Vitreous State Laboratory (VSL) for Department of Energy's (DOE's) Office of River Protection (ORP) to increase waste loading and processing rates for high-iron HLW waste streams as well as previous tests conducted for ORP on the same waste composition. This Test Plan is prepared in response to an ORP-supplied statement of work. It is currently estimated that the number of HLW canisters to be produced in the Hanford Tank Waste Treatment and Immobilization Plant (WTP) is about 12,500. This estimate is based upon the inventory ofthe tank wastes, the anticipated performance of the sludge treatment processes, and current understanding of the capability of the borosilicate glass waste form. The WTP HLW melter design, unlike earlier DOE melter designs, incorporates an active glass bubbler system. The bubblers create active glass pool convection and thereby improve heat

  10. Genotoxicity detected in wild mice living in a highly polluted wetland area in south western Spain

    Energy Technology Data Exchange (ETDEWEB)

    Mateos, Santiago; Daza, Paula; Dominguez, Inmaculada; Cardenas, Jose Antonio [University of Seville, Department of Cell Biology, Faculty of Biology, Avenida de la Reina Mercedes no 6, E-41012 Seville (Spain); Cortes, Felipe [University of Seville, Department of Cell Biology, Faculty of Biology, Avenida de la Reina Mercedes no 6, E-41012 Seville (Spain)], E-mail: cortes@us.es

    2008-06-15

    A field study was carried out in the south of the Iberian Peninsula in an industrial area in the neighbourhood of Huelva city, SW Spain, and in a natural area (Donana National Park) for comparison, to estimate the genetic risk induced by environmental pollution in wild mice. Genotoxic effects in a sentinel organism, the Algerian mice (Mus spretus) free living in the industrial area were compared with animals of the same species living in the natural protected area. The single cell gel electrophoresis, or Comet assay, was performed as a genotoxicity test in peripheral blood of mice. Our results clearly show that mice free living in the contaminated area bear a high burden of genetic damage as compared with control individuals. The results suggest that the assessing of genotoxicity levels by the Comet assay in wild mice can be used as a valuable test in pollution monitoring and environmental conservation. - We have found an increased genotoxic damage in wild mice in a highly polluted area from industry, mining and agriculture in SW Spain, as assessed by the Comet assay.

  11. DETECTION AND QUANTIFICATION OF COW FECAL POLLUTION WITH REAL-TIME PCR

    Science.gov (United States)

    Assessment of health risk and fecal bacteria loads associated with cow fecal pollution requires a reliable host-specific genetic marker and a rapid quantification method. We report the development of quantitative PCR assays for enumeration of two recently described cow-specific g...

  12. Is acidification still a major air pollution concern?; L`acidification est-elle encore un probleme majeur de pollution atmospherique?

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-31

    Although other forms of long-range air pollution are gaining attention, acidification remains an important issue in certain parts of Europe as well as in other continents. In spite of the European 88/609 directive limiting acid emissions from large fuel burning plants, a large part of Europe soils receives acid deposits superior to the tolerance threshold, known as critical loads. Thus, the European Union is considering several new measures, such as a more drastic 88/609 directive, the limitation of emissions country by country, the limitation of sulfur content in heavy fuels, etc. Emission inventories, evaluation tools, long range transfrontier pollution models, integrated assessment, etc. are presented, together with the positions of various French governmental departments, public authorities and industries concerning the european strategy against acidification

  13. High power passive μDMFC with low catalyst loading for small power generation

    International Nuclear Information System (INIS)

    Ahmad, M.M.; Kamarudin, S.K.; Daud, W.R.W.; Yaakub, Z.

    2010-01-01

    The main constraint for commercialization of micro direct methanol fuel cell (μDMFC) for small power generation is the performance of the fuel cell. In this study, a high power μDMFC with a power output of 56 mW and an active area of 4 cm 2 was successfully developed. The cell required low catalyst loading of 5 mg cm -2 and 0.5 mg cm -2 at the anode and cathode, respectively. Optimal design parameters for methanol concentration and catalyst loading were examined. Finally, long-term performance testing was performed and OCV curves are reported. The results obtained for this gives the highest power density at low catalyst loading as compare to other researchers in this area.

  14. Morus nigra plant leaves as biomonitor for elemental air pollution monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Daud, M.; Khalid, N.; Waheed, S.; Wasim, M.; Arif, M.; Zaidi, J.H. [Pakistan Institute of Nuclear Science and Technology, Islamabad (Pakistan). Chemistry Div.

    2011-07-01

    The present paper deals with the determination of 36 elements in 120 leaf samples of Morus nigra plant to assess their potential as biomonitor for elemental air pollution monitoring. The elemental quantification was made by employing Instrumental Neutron Activation Analysis (INAA) and Atomic Absorption Spectrometric (AAS) techniques. The leaf samples were collected in spring, summer and winter seasons from various sites in Islamabad with different types of anthropogenic activities as well as from a reference site with minimum of such activities. Twenty four soil samples from the respective sites were also analyzed. The reliability of the adopted procedures was established by analyzing the certified reference materials, i.e., citrus leaves-1572 and soil-7, from NIST and IAEA, respectively, under identical experimental conditions and comparing the results obtained with the certified values which are in quite good agreement with each other. The enrichment values and Pollution Load Index (PLI) of the determined elements were computed and discussed accordingly. The elemental translocation from soil to roots, stem and leaves has also been studied by analyzing these parts of the same plant. The results indicated that the leaves of Morus nigra plant have promising potential to monitor the extent of air pollution in the vicinity of industrial as well as in high traffic areas. (orig.)

  15. Fusion surface material melting, ablation, and ejection under high heat loading

    International Nuclear Information System (INIS)

    Holliday, M.R.; Doster, J.M.; Gilligan, J.G.

    1986-01-01

    Limiters, divertor plates, and sections of the first wall are exposed to intense heat loads during normal operation and plasma disruptions. This results in severe thermal stresses as well as erosion of the surface material. Large surface areas of compact high-field tokamaks are expected to be exposed to these high heat loads. The need for a fast and accurate computational model describing the heat transfer and phase change process has arisen as a part of the larger model of the plasma-edge region. The authors report on a solution scheme that has been developed that minimizes computational time for this time-dependent, one-dimensional, moving boundary problem. This research makes use of the heat balance integral technique, which is at least an order of magnitude faster than previous finite difference techniques. In addition, we report on the effect of molten material ejection (by external forces) on the total surface erosion rate

  16. Multiscale Framework for Assessing Critical Loads of Atmospheric Nitrogen Deposition for Aquatic Ecosystems in Wilderness Areas of the Western United States

    Science.gov (United States)

    Nanus, Leora; Clow, David; Saros, Jasmine; McMurray, Jill; Blett, Tamara; Sickman, James

    2017-04-01

    High-elevation aquatic ecosystems in Wilderness areas of the western United States are impacted by current and historic atmospheric nitrogen (N) deposition associated with local and regional air pollution. Documented effects include elevated surface water nitrate concentrations, increased algal productivity, and changes in diatom species assemblages. A predictive framework was developed for sensitive high-elevation basins across the western United States at multiple spatial scales including the Rocky Mountain Region (Rockies), the Greater Yellowstone Area (GYA), and Yosemite (YOSE) and Sequoia & Kings Canyon (SEKI) National Parks. Spatial trends in critical loads of N deposition for nutrient enrichment of aquatic ecosystems were quantified and mapped using a geostatistical approach, with modeled N deposition, topography, vegetation, geology, and climate as potential explanatory variables. Multiple predictive models were created using various combinations of explanatory variables; this approach allowed for better quantification of uncertainty and identification of areas most sensitive to high atmospheric N deposition (> 3 kg N ha-1 yr-1). For multiple spatial scales, the lowest critical loads estimates (1.5 + 1 kg N ha-1 yr-1) correspond with areas of high N deposition and vary spatially ranging from less than 20% to over 40% of the study area for the Rockies, GYA, YOSE, and SEKI. These predictive models and maps identify sensitive aquatic ecosystems that may be impacted by excess atmospheric N deposition and can be used to help protect against future anthropogenic disturbance. The approach presented here may be transferable to other remote and protected high-elevation ecosystems at multiple spatial scales that are sensitive to adverse effects of pollutant loading in the US and around the world.

  17. Reducing the pollutant load of olive mill wastewater by photocatalytic membranes and monitoring the process using both tyrosinase biosensor and COD test

    Directory of Open Access Journals (Sweden)

    Elisabetta eMartini

    2013-12-01

    Full Text Available Photocatalytic technique had already been employed in the treatment of olive mill wastewater (OMW using the photocatalysis in suspension. The coupling of photocatalytic and membrane techniques should result in a very powerful process bringing great innovation to OMW depollution. Despite the potential advantages using these hybrid photoreactors, research on the combined use of photocatalysis and membranes has so far not been sufficiently developed. The present paper describes a study to assess the photocatalytic efficacy of a new ceramic membrane containing titanium dioxide, irradiated by UV light, used to abate the pollutant load of olive mill wastewater. Good results were obtained (more than 90% of the phenol content was removed and the COD decrease was of the order of 46-51 % in 24 h particularly using the ceramic membrane compared with those offered by analogous catalytic membranes made of metallic or polymeric materials.

  18. Low-load high volume resistance exercise stimulates muscle protein synthesis more than high-load low volume resistance exercise in young men.

    Directory of Open Access Journals (Sweden)

    Nicholas A Burd

    Full Text Available BACKGROUND: We aimed to determine the effect of resistance exercise intensity (%1 repetition maximum-1RM and volume on muscle protein synthesis, anabolic signaling, and myogenic gene expression. METHODOLOGY/PRINCIPAL FINDINGS: Fifteen men (21+/-1 years; BMI=24.1+/-0.8 kg/m2 performed 4 sets of unilateral leg extension exercise at different exercise loads and/or volumes: 90% of repetition maximum (1RM until volitional failure (90FAIL, 30% 1RM work-matched to 90%FAIL (30WM, or 30% 1RM performed until volitional failure (30FAIL. Infusion of [ring-13C6] phenylalanine with biopsies was used to measure rates of mixed (MIX, myofibrillar (MYO, and sarcoplasmic (SARC protein synthesis at rest, and 4 h and 24 h after exercise. Exercise at 30WM induced a significant increase above rest in MIX (121% and MYO (87% protein synthesis at 4 h post-exercise and but at 24 h in the MIX only. The increase in the rate of protein synthesis in MIX and MYO at 4 h post-exercise with 90FAIL and 30FAIL was greater than 30WM, with no difference between these conditions; however, MYO remained elevated (199% above rest at 24 h only in 30FAIL. There was a significant increase in AktSer473 at 24h in all conditions (P=0.023 and mTORSer2448 phosphorylation at 4 h post-exercise (P=0.025. Phosporylation of Erk1/2Tyr202/204, p70S6KThr389, and 4E-BP1Thr37/46 increased significantly (P<0.05 only in the 30FAIL condition at 4 h post-exercise, whereas, 4E-BP1Thr37/46 phosphorylation was greater 24 h after exercise than at rest in both 90FAIL (237% and 30FAIL (312% conditions. Pax7 mRNA expression increased at 24 h post-exercise (P=0.02 regardless of condition. The mRNA expression of MyoD and myogenin were consistently elevated in the 30FAIL condition. CONCLUSIONS/SIGNIFICANCE: These results suggest that low-load high volume resistance exercise is more effective in inducing acute muscle anabolism than high-load low volume or work matched resistance exercise modes.

  19. Hydrological modeling of a watershed affected by acid mine drainage (Odiel River, SW Spain). Assessment of the pollutant contributing areas

    Science.gov (United States)

    Galván, L.; Olías, M.; Cánovas, C. R.; Sarmiento, A. M.; Nieto, J. M.

    2016-09-01

    The Odiel watershed drains materials belonging to the Iberian Pyrite Belt, where significant massive sulfide deposits have been mined historically. As a result, a huge amount of sulfide-rich wastes are deposited in the watershed, which suffer from oxidation, releasing acidic lixiviates with high sulfate and metal concentrations. In order to reliably estimate the metal loadings along the watershed a complete series of discharge and hydrochemical data are essential. A hydrological model was performed with SWAT (Soil and Water Assessment Tool) to solve the scarcity of gauge stations along the watershed. The model was calibrated and validated from daily discharge data (from 1980 to 2010) at the outlet of the watershed, river inputs into an existent reservoir, and a flow gauge station close to the northern area of the watershed. Discharge data obtained from the hydrological model, together with analytical data, allowed the estimation of the dissolved pollutant load delivered annually by the Odiel River (e.g. 9140 t of Al, 2760 t of Zn). The pollutant load is influenced strongly by the rainfall regime, and can even double during extremely rainy years. Around 50% of total pollution comes from the Riotinto Mining District, so the treatment of Riotinto lixiviates reaching the Odiel watershed would reduce the AMD (Acid Mine Drainages) in a remarkable way, improving the water quality downstream, especially in the reservoir of Alcolea, currently under construction. The information obtained in this study will allow the optimization of remediation efforts in the watershed, in order to improve its water quality.

  20. High spatio-temporal resolution pollutant measurements of on-board vehicle emissions using ultra-fast response gas analyzers

    Directory of Open Access Journals (Sweden)

    M. Irwin

    2018-06-01

    Full Text Available Existing ultra-fast response engine exhaust emissions analyzers have been adapted for on-board vehicle use combined with GPS data. We present, for the first time, how high spatio-temporal resolution data products allow transient features associated with internal combustion engines to be examined in detail during on-road driving. Such data are both useful to examine the circumstances leading to high emissions, and reveals the accurate position of urban air quality hot spots as deposited by the candidate vehicle, useful for source attribution and dispersion modelling. The fast response time of the analyzers, which results in 100 Hz data, makes accurate time-alignment with the vehicle's engine control unit (ECU signals possible. This enables correlation with transient air fuel ratio, engine speed, load, and other engine parameters, which helps to explain the causes of the emissions spikes that portable emissions measurement systems (PEMS and conventional slow response analyzers would miss or smooth out due to mixing within their sampling systems. The data presented is from NO and NOx analyzers, but other fast analyzers (e.g. total hydrocarbons (THC, CO and CO2 can be used similarly. The high levels of NOx pollution associated with accelerating on entry ramps to motorways, driving over speed bumps, accelerating away from traffic lights, are explored in detail. The time-aligned ultra-fast analyzers offer unique insight allowing more accurate quantification and better interpretation of engine and driver activity and the associated emissions impact on local air quality.