WorldWideScience

Sample records for high oxygen tensions

  1. A microfluidic cell culture array with various oxygen tensions.

    Science.gov (United States)

    Peng, Chien-Chung; Liao, Wei-Hao; Chen, Ying-Hua; Wu, Chueh-Yu; Tung, Yi-Chung

    2013-08-21

    Oxygen tension plays an important role in regulating various cellular functions in both normal physiology and disease states. Therefore, drug testing using conventional in vitro cell models under normoxia often possesses limited prediction capability. A traditional method of setting an oxygen tension in a liquid medium is by saturating it with a gas mixture at the desired level of oxygen, which requires bulky gas cylinders, sophisticated control, and tedious interconnections. Moreover, only a single oxygen tension can be tested at the same time. In this paper, we develop a microfluidic cell culture array platform capable of performing cell culture and drug testing under various oxygen tensions simultaneously. The device is fabricated using an elastomeric material, polydimethylsiloxane (PDMS) and the well-developed multi-layer soft lithography (MSL) technique. The prototype device has 4 × 4 wells, arranged in the same dimensions as a conventional 96-well plate, for cell culture. The oxygen tensions are controlled by spatially confined oxygen scavenging chemical reactions underneath the wells using microfluidics. The platform takes advantage of microfluidic phenomena while exhibiting the combinatorial diversities achieved by microarrays. Importantly, the platform is compatible with existing cell incubators and high-throughput instruments (liquid handling systems and plate readers) for cost-effective setup and straightforward operation. Utilizing the developed platform, we successfully perform drug testing using an anti-cancer drug, triapazamine (TPZ), on adenocarcinomic human alveolar basal epithelial cell line (A549) under three oxygen tensions ranging from 1.4% to normoxia. The developed platform is promising to provide a more meaningful in vitro cell model for various biomedical applications while maintaining desired high throughput capabilities.

  2. Optic nerve oxygen tension

    DEFF Research Database (Denmark)

    la Cour, M; Kiilgaard, Jens Folke; Eysteinsson, T

    2000-01-01

    To investigate the influence of acute changes in intraocular pressure on the oxygen tension in the vicinity of the optic nerve head under control conditions and after intravenous administration of 500 mg of the carbonic anhydrase inhibitor dorzolamide.......To investigate the influence of acute changes in intraocular pressure on the oxygen tension in the vicinity of the optic nerve head under control conditions and after intravenous administration of 500 mg of the carbonic anhydrase inhibitor dorzolamide....

  3. Mitochondrial Respiration and Oxygen Tension.

    Science.gov (United States)

    Shaw, Daniel S; Meitha, Karlia; Considine, Michael J; Foyer, Christine H

    2017-01-01

    Measurements of respiration and oxygen tension in plant organs allow a precise understanding of mitochondrial capacity and function within the context of cellular oxygen metabolism. Here we describe methods that can be routinely used for the isolation of intact mitochondria, and the determination of respiratory electron transport, together with techniques for in vivo determination of oxygen tension and measurement of respiration by both CO 2 production and O 2 consumption that enables calculation of the respiratory quotient [CO 2 ]/[O 2 ].

  4. Oxygen tension level and human viral infections

    Energy Technology Data Exchange (ETDEWEB)

    Morinet, Frédéric, E-mail: frederic.morinet@sls.aphp.fr [Centre des Innovations Thérapeutiques en Oncologie et Hématologie (CITOH), CHU Saint-Louis, Paris (France); Université Denis Diderot, Sorbonne Paris Cité Paris, Paris (France); Casetti, Luana [Institut Cochin INSERM U1016, Paris (France); François, Jean-Hugues; Capron, Claude [Institut Cochin INSERM U1016, Paris (France); Laboratoire d' Hématologie, Hôpital Ambroise Paré, Boulogne (France); Université de Versailles Saint-Quentin en Yvelynes, Versailles (France); Pillet, Sylvie [Laboratoire de Bactériologie-Virologie-Hygiène, CHU de Saint-Etienne, Saint-Etienne (France); Université de Lyon et Université de Saint-Etienne, Jean Monnet, GIMAP EA3064, F-42023 Saint-Etienne, Lyon (France)

    2013-09-15

    The role of oxygen tension level is a well-known phenomenon that has been studied in oncology and radiotherapy since about 60 years. Oxygen tension may inhibit or stimulate propagation of viruses in vitro as well as in vivo. In turn modulating oxygen metabolism may constitute a novel approach to treat viral infections as an adjuvant therapy. The major transcription factor which regulates oxygen tension level is hypoxia-inducible factor-1 alpha (HIF-1α). Down-regulating the expression of HIF-1α is a possible method in the treatment of chronic viral infection such as human immunodeficiency virus infection, chronic hepatitis B and C viral infections and Kaposi sarcoma in addition to classic chemotherapy. The aim of this review is to supply an updating concerning the influence of oxygen tension level in human viral infections and to evoke possible new therapeutic strategies regarding this environmental condition. - Highlights: • Oxygen tension level regulates viral replication in vitro and possibly in vivo. • Hypoxia-inducible factor 1 (HIF-1α) is the principal factor involved in Oxygen tension level. • HIF-1α upregulates gene expression for example of HIV, JC and Kaposi sarcoma viruses. • In addition to classical chemotherapy inhibition of HIF-1α may constitute a new track to treat human viral infections.

  5. Optic nerve oxygen tension

    DEFF Research Database (Denmark)

    Kiilgaard, Jens Folke; Pedersen, D B; Eysteinsson, T

    2004-01-01

    The authors have previously reported that carbonic anhydrase inhibitors such as acetazolamide and dorzolamide raise optic nerve oxygen tension (ONPO(2)) in pigs. The purpose of the present study was to investigate whether timolol, which belongs to another group of glaucoma drugs called beta...

  6. Carbonic anhydrase inhibition increases retinal oxygen tension and dilates retinal vessels

    DEFF Research Database (Denmark)

    Pedersen, Daniella Bach; Koch Jensen, Peter; la Cour, Morten

    2005-01-01

    Carbonic anhydrase inhibitors (CAIs) increase blood flow in the brain and probably also in the optic nerve and retina. Additionally they elevate the oxygen tension in the optic nerve in the pig. We propose that they also raise the oxygen tension in the retina. We studied the oxygen tension in the...... in the pig retina and optic nerve before and after dorzolamide injection. Also the retinal vessel diameters during carbonic anhydrase inhibition were studied....

  7. Oxygen tension and oocyte density during in vitro maturation affect the in vitro fertilization of bovine oocytes

    Directory of Open Access Journals (Sweden)

    Angelo Bertani Giotto

    2015-12-01

    Full Text Available Oocyte maturation is the key factor affecting the fertilization and embryonic development. Factors such as oocyte density and oxygen tension can directly influence the IMV. Thus, the objective of this study was to evaluate the effect of the association of oxygen tensions (5% or 20% with different oocyte densities (1:10?l or 1:20?l in the in vitro maturation (IVM of bovine oocytes on maturation and fertilization rates, ROS production and antioxidant activity. Three experiments were performed with bovine oocytes that were obtained from slaughterhouse ovaries. After selection, the oocytes were randomly distributed in four treatments: 1:10/5%; 1:10/20%; 1:20/5%and 1:20/20% for each experiment. In experiment I, nuclear maturation status and cytoplasmic maturation were evaluated through detection of the first polar body by immunofluorescence and the mitochondrial reorganization assay. In experiment II, ROS production and antioxidant activity were analyzed in oocytes and IVM medium after 24 h of maturation through detection of ROS, reduced glutathione (GSH and Superoxide dismutase activity by spectrofluorimetric methods. In experiment III, fertilization was evaluated through pronucleus formation, sperm penetration with or without decondensation and polyspermy rates by immunofluorescence. In experiment I, the nuclear maturation and cytoplasmic maturation were similar among treatments (P>0.05. In experiment II, reactive oxygen species in oocytes were elevated in treatments with low oxygen tension which was independent of oocyte density (P<0.05. Additionally, ROS levels in IVM medium were higher in treatments with high oocyte density by volume of medium, which was independent of oxygen tension (P<0.05. In Experiment III, the fertilization and penetration rates were higher in the treatment with 20% oxygen tension and high oocyte density (P<0.05. Furthermore, a high incidence of polyspermy was observed in groups with high oxygen tension and low oocyte

  8. Dorzolamide increases retinal oxygen tension after branch retinal vein occlusion

    DEFF Research Database (Denmark)

    Noergaard, Michael Hove; Bach-Holm, Daniella; Scherfig, Erik

    2008-01-01

    To study the effect of dorzolamide on the preretinal oxygen tension (RPO(2)) in retinal areas affected by experimental branch retinal vein occlusion (BRVO) in pigs.......To study the effect of dorzolamide on the preretinal oxygen tension (RPO(2)) in retinal areas affected by experimental branch retinal vein occlusion (BRVO) in pigs....

  9. Low physiologic oxygen tensions reduce proliferation and differentiation of human multipotent mesenchymal stromal cells

    Directory of Open Access Journals (Sweden)

    Handgretinger Rupert

    2010-01-01

    Full Text Available Abstract Background Human multipotent mesenchymal stromal cells (MSC can be isolated from various tissues including bone marrow. Here, MSC participate as bone lining cells in the formation of the hematopoietic stem cell niche. In this compartment, the oxygen tension is low and oxygen partial pressure is estimated to range from 1% to 7%. We analyzed the effect of low oxygen tensions on human MSC cultured with platelet-lysate supplemented media and assessed proliferation, morphology, chromosomal stability, immunophenotype and plasticity. Results After transferring MSC from atmospheric oxygen levels of 21% to 1%, HIF-1α expression was induced, indicating efficient oxygen reduction. Simultaneously, MSC exhibited a significantly different morphology with shorter extensions and broader cell bodies. MSC did not proliferate as rapidly as under 21% oxygen and accumulated in G1 phase. The immunophenotype, however, was unaffected. Hypoxic stress as well as free oxygen radicals may affect chromosomal stability. However, no chromosomal abnormalities in human MSC under either culture condition were detected using high-resolution matrix-based comparative genomic hybridization. Reduced oxygen tension severely impaired adipogenic and osteogenic differentiation of human MSC. Elevation of oxygen from 1% to 3% restored osteogenic differentiation. Conclusion Physiologic oxygen tension during in vitro culture of human MSC slows down cell cycle progression and differentiation. Under physiological conditions this may keep a proportion of MSC in a resting state. Further studies are needed to analyze these aspects of MSC in tissue regeneration.

  10. Enhanced proliferation and dopaminergic differentiation of ventral mesencephalic precursor cells by synergistic effect of FGF2 and reduced oxygen tension

    DEFF Research Database (Denmark)

    Jensen, Pia; Gramsbergen, Jan-Bert; Zimmer, Jens

    2011-01-01

    Effective numerical expansion of dopaminergic precursors might overcome the limited availability of transplantable cells in replacement strategies for Parkinson's disease. Here we investigated the effect of fibroblast growth factor-2 (FGF2) and FGF8 on expansion and dopaminergic differentiation o...... enzyme activity, which may explain the elevated dopamine levels. Our findings demonstrate that modulation of oxygen tension is a recognizable factor for in vitro expansion and dopaminergic differentiation of rat embryonic midbrain precursor cells....... of rat embryonic ventral mesencephalic neuroblasts cultured at high (20%) and low (3%) oxygen tension. More cells incorporated bromodeoxyuridine in cultures expanded at low as compared to high oxygen tension, and after 6 days of differentiation there were significantly more neuronal cells in low than......, switching FGF2-expanded cultures from low to high oxygen tension during the last two days of differentiation significantly enhanced dopamine release and intracellular dopamine levels as compared to all other treatment groups. In addition, the short-term exposure to high oxygen enhanced in situ assessed TH...

  11. Effect of pneumatic tourniquet on muscle oxygen tension.

    Science.gov (United States)

    Santavirta, S; Höckerstedt, K; Niinikoski, J

    1978-10-01

    Recent investigations suggest that circulation in a limb can be reduced with a tourniquet to less than 1 per cent of the control limb, or even completely occluded. The development of tissue oxygen tonometry with implanted silastic tubes has provided new possibilities for assessing muscle tissue oxygen tension. In the present work, this method was employed to register the effect of tourniquet blackade on the lower limb muscle PO2 in rabbits. The duration of the tourniquet blockade was 60, 120 and 180 minutes. The baseline muscle PO2 in the tibialis anterior muscle was 22.6 +/- 0.6 mmHg. During the tourniquet blockade the oxygen tension dropped to minimal values between 9.2 +/- 0.5 and 10.7 +/- 0.6 mmHg in these experimental groups, but the tissue microclimate never reached fully anoxic conditions. The rapid response of muscle PO2 to oxygen breathing after release of the blockade suggests that limb microcirculation tolerates tourniquet occlusion well.

  12. Renal transplantation induces mitochondrial uncoupling, increased kidney oxygen consumption, and decreased kidney oxygen tension

    NARCIS (Netherlands)

    Papazova, Diana A.; Friederich-Persson, Malou; Joles, Jaap A.; Verhaar, Marianne C.

    2015-01-01

    Hypoxia is an acknowledged pathway to renal injury and ischemia-reperfusion (I/R) and is known to reduce renal oxygen tension (PO2). We hypothesized that renal I/R increases oxidative damage and induces mitochondrial uncoupling, resulting in increased oxygen consumption and hence kidney

  13. Transcutaneous oxygen tension in imminent foot gangrene

    DEFF Research Database (Denmark)

    Tønnesen, K H

    1978-01-01

    Transcutaneous oxygen tension at 44 degree C and maximal isotope clearance (90m Tc-pretechnetate + histramine) just proximal to the 1st toe and systolic toe blood pressure (strain gauge) were studied on a tilt table in patients with various degrees of obstructive arteriosclerotic disease. In legs...

  14. Optic nerve oxygen tension in pigs and the effect of carbonic anhydrase inhibitors

    DEFF Research Database (Denmark)

    Stefánsson, E; Jensen, P K; Eysteinsson, T

    1999-01-01

    To evaluate how the oxygen tension of the optic nerve (ONP(O)2) is affected by the administration of the carbonic anhydrase inhibitors dorzolamide and acetazolamide and by alterations in oxygen and carbon dioxide in the breathing mixture.......To evaluate how the oxygen tension of the optic nerve (ONP(O)2) is affected by the administration of the carbonic anhydrase inhibitors dorzolamide and acetazolamide and by alterations in oxygen and carbon dioxide in the breathing mixture....

  15. Changes in transcutaneous oxygen tension during exercise in pulmonary emphysema.

    OpenAIRE

    Hughes, J A; Gray, B J; Hutchison, D C

    1984-01-01

    Continuous measurements of transcutaneous oxygen tension (tcPO2) were made in 23 patients with radiological evidence of emphysema, at rest and during a maximal progressive exercise test. tcPO2 during the final phase of exercise was compared with tcPO2 at rest; the mean change (exercising minus resting value) in tcPO2 (delta tcPO2) was -0.8 mm Hg (SD 10.5, range -18 to +25) (-0.1 kPa (SD 1.4, range -2.4 to +3.3]. delta tcPO2 was correlated with: resting arterial oxygen tension (PaO2) (r = 0.60...

  16. Oxygen Tension in the Aqueous Humor of Human Eyes under Different Oxygenation Conditions

    Directory of Open Access Journals (Sweden)

    Farideh Sharifipour

    2013-01-01

    Full Text Available Purpose: To measure oxygen tension in the aqueous humor of human eyes under different oxygenation conditions. Methods: This prospective comparative interventional case series consisted of two parts. In the first part, 120 consecutive patients scheduled for cataract surgery were randomized into group I (control group in which surgery was performed under local anesthesia inhaling 21% oxygen; group II in whom general anesthesia using 50% oxygen was employed; and group III receiving general anesthesia with 100% oxygen. After aspirating 0.2 ml aqueous humor under sterile conditions, the aqueous sample and a simultaneously drawn arterial blood sample were immediately analyzed using a blood gas analyzer. In part II the same procedures were performed in 10 patients after fitting a contact lens and patching the eye for 20 minutes (group IV and in 10 patients after transcorneal delivery of oxygen at a flow rate of 5 L/min (group V. Results: Mean aqueous PO2 in groups I, II and III was 112.3±6.2, 141.1±20.4, and 170.1±27 mmHg, respectively (P values <0.001 and mean arterial PO2 was 85.7±7.9, 184.6±46, and 379.1±75.9 mmHg, respectively (P values <0.001. Aqueous PO2 was 77.2±9.2 mmHg in group IV and 152.3±10.9 mmHg in group V (P values <0.001. There was a significant correlation between aqueous and blood PO2 (r=0.537, P<0.001. The contribution of atmospheric oxygen to aqueous PO2 was 23.7%. Conclusion: Aqueous oxygen tension is mostly dependent on the systemic circulation and in part on the atmosphere. Increasing inspiratory oxygen and transcorneal oxygen delivery both increase aqueous PO2 levels.

  17. Hemodynamic parameters change earlier than tissue oxygen tension in hemorrhage.

    Science.gov (United States)

    Pestel, Gunther J; Fukui, Kimiko; Kimberger, Oliver; Hager, Helmut; Kurz, Andrea; Hiltebrand, Luzius B

    2010-05-15

    Untreated hypovolemia results in impaired outcome. This study tests our hypothesis whether general hemodynamic parameters detect acute blood loss earlier than monitoring parameters of regional tissue beds. Eight pigs (23-25 kg) were anesthetized and mechanically ventilated. A pulmonary artery catheter and an arterial catheter were inserted. Tissue oxygen tension was measured with Clark-type electrodes in the jejunal and colonic wall, in the liver, and subcutaneously. Jejunal microcirculation was assessed by laser Doppler flowmetry (LDF). Intravascular volume was optimized using difference in pulse pressure (dPP) to keep dPP below 13%. Sixty minutes after preparation, baseline measurements were taken. At first, 5% of total blood volume was withdrawn, followed by another 5% increment, and then in 10% increments until death. After withdrawal of 5% of estimated blood volume, dPP increased from 6.1% +/- 3.0% to 20.8% +/- 2.7% (P < 0.01). Mean arterial pressure (MAP), mean pulmonary artery pressure (PAP) and pulmonary artery occlusion pressure (PAOP) decreased with a blood loss of 10% (P < 0.01). Cardiac output (CO) changed after a blood loss of 20% (P < 0.05). Tissue oxygen tension in central organs, and blood flow in the jejunal muscularis decreased (P < 0.05) after a blood loss of 20%. Tissue oxygen tension in the skin, and jejunal mucosa blood flow decreased (P < 0.05) after a blood loss of 40% and 50%, respectively. In this hemorrhagic pig model systemic hemodynamic parameters were more sensitive to detect acute hypovolemia than tissue oxygen tension measurements or jejunal LDF measurements. Acute blood loss was detected first by dPP. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  18. A Method for Combined Retinal Vascular and Tissue Oxygen Tension Imaging.

    Science.gov (United States)

    Felder, Anthony E; Wanek, Justin; Tan, Michael R; Blair, Norman P; Shahidi, Mahnaz

    2017-09-06

    The retina requires adequate oxygenation to maintain cellular metabolism and visual function. Inner retinal oxygen metabolism is directly related to retinal vascular oxygen tension (PO 2 ) and inner retinal oxygen extraction fraction (OEF), whereas outer retinal oxygen consumption (QO 2 ) relies on oxygen availability by the choroid and is contingent upon retinal tissue oxygen tension (tPO 2 ) gradients across the retinal depth. Thus far, these oxygenation and metabolic parameters have been measured independently by different techniques in separate animals, precluding a comprehensive and correlative assessment of retinal oxygenation and metabolism dynamics. The purpose of the current study is to report an innovative optical system for dual oxyphor phosphorescence lifetime imaging to near-simultaneously measure retinal vascular PO 2 and tPO 2 in rats. The use of a new oxyphor with different spectral characteristics allowed differentiation of phosphorescence signals from the retinal vasculature and tissue. Concurrent measurements of retinal arterial and venous PO 2 , tPO 2 through the retinal depth, inner retinal OEF, and outer retinal QO 2 were demonstrated, permitting a correlative assessment of retinal oxygenation and metabolism. Future application of this method can be used to investigate the relations among retinal oxygen content, extraction and metabolism under pathologic conditions and thus advance knowledge of retinal hypoxia pathophysiology.

  19. In vivo mitochondrial oxygen tension measured by a delayed fluorescence lifetime technique

    NARCIS (Netherlands)

    Mik, Egbert G.; Johannes, Tanja; Zuurbier, Coert J.; Heinen, Andre; Houben-Weerts, Judith H. P. M.; Balestra, Gianmarco M.; Stap, Jan; Beek, Johan F.; Ince, Can

    2008-01-01

    Mitochondrial oxygen tension (mitoPO(2)) is a key parameter for cellular function, which is considered to be affected under various pathophysiological circumstances. Although many techniques for assessing in vivo oxygenation are available, no technique for measuring mitoPO(2) in vivo exists. Here we

  20. Impact of low oxygen tension on stemness, proliferation and differentiation potential of human adipose-derived stem cells

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jane Ru; Pingguan-Murphy, Belinda; Wan Abas, Wan Abu Bakar [Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Lembah Pantai, 50603 Kuala Lumpur (Malaysia); Noor Azmi, Mat Adenan; Omar, Siti Zawiah [Department of Obstetrics and Gynaecology, Faculty of Medicine, University of Malaya, Lembah Pantai, 50603 Kuala Lumpur (Malaysia); Chua, Kien Hui [Department of Physiology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Raja Muda Abdul Aziz, 50300 Kuala Lumpur (Malaysia); Wan Safwani, Wan Kamarul Zaman, E-mail: wansafwani@um.edu.my [Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Lembah Pantai, 50603 Kuala Lumpur (Malaysia)

    2014-05-30

    Highlights: • Hypoxia maintains the stemness of adipose-derived stem cells (ASCs). • ASCs show an increased proliferation rate under low oxygen tension. • Oxygen level as low as 2% enhances the chondrogenic differentiation potential of ASCs. • HIF-1α may regulate the proliferation and differentiation activities of ASCs under hypoxia. - Abstract: Adipose-derived stem cells (ASCs) have been found adapted to a specific niche with low oxygen tension (hypoxia) in the body. As an important component of this niche, oxygen tension has been known to play a critical role in the maintenance of stem cell characteristics. However, the effect of O{sub 2} tension on their functional properties has not been well determined. In this study, we investigated the effects of O{sub 2} tension on ASCs stemness, differentiation and proliferation ability. Human ASCs were cultured under normoxia (21% O{sub 2}) and hypoxia (2% O{sub 2}). We found that hypoxia increased ASC stemness marker expression and proliferation rate without altering their morphology and surface markers. Low oxygen tension further enhances the chondrogenic differentiation ability, but reduces both adipogenic and osteogenic differentiation potential. These results might be correlated with the increased expression of HIF-1α under hypoxia. Taken together, we suggest that growing ASCs under 2% O{sub 2} tension may be important in expanding ASCs effectively while maintaining their functional properties for clinical therapy, particularly for the treatment of cartilage defects.

  1. [Long-term expansion of multipotent mesenchymal stromal cells under reduced oxygen tension].

    Science.gov (United States)

    Rylova, Iu V; Buravkova, L B

    2013-01-01

    We have shown that the decrease in oxygen tension in the culture medium of multipotent mesenchymal stromal cells (MMSCs) results in a short-term reduction in the proportion of CD73(+)-cells in the population, without effecting the number of cells expressing other constitutive surface markers (CD90 and CD105). In this case, the heterogeneity of the cell population declined: large spread cells disappeared. The proliferative activity of MMSCs significantly increased and remained stable in conditions in which the oxygen content was close to the tissue oxygen levels (5% O2). At lower oxygen concentration, proliferative activity of the cells gradually reduced from passages 3-4. The increase in proliferative activity was not accompanied by increased expression of telomerase gene indicateding the alsance of cell transformation. However, genome-wide analysis of MMSC gene expression level revealed changes in expression of cyclins (CCND2 and PCNA), regulatory subunit cyclin-dependent kinase (CKS2) and an inhibitor of cyclin-dependent kinase (CDKN2C), regulating the cell cycle, which is obviously facilitated the increase in the proliferative capacity of cells at lower oxygen tension.

  2. Control of oxygen tension recapitulates zone-specific functions in human liver microphysiology systems.

    Science.gov (United States)

    Lee-Montiel, Felipe T; George, Subin M; Gough, Albert H; Sharma, Anup D; Wu, Juanfang; DeBiasio, Richard; Vernetti, Lawrence A; Taylor, D Lansing

    2017-10-01

    This article describes our next generation human Liver Acinus MicroPhysiology System (LAMPS). The key demonstration of this study was that Zone 1 and Zone 3 microenvironments can be established by controlling the oxygen tension in individual devices over the range of ca. 3 to 13%. The oxygen tension was computationally modeled using input on the microfluidic device dimensions, numbers of cells, oxygen consumption rates of hepatocytes, the diffusion coefficients of oxygen in different materials and the flow rate of media in the MicroPhysiology System (MPS). In addition, the oxygen tension was measured using a ratiometric imaging method with the oxygen sensitive dye, Tris(2,2'-bipyridyl) dichlororuthenium(II) hexahydrate (RTDP) and the oxygen insensitive dye, Alexa 488. The Zone 1 biased functions of oxidative phosphorylation, albumin and urea secretion and Zone 3 biased functions of glycolysis, α1AT secretion, Cyp2E1 expression and acetaminophen toxicity were demonstrated in the respective Zone 1 and Zone 3 MicroPhysiology System. Further improvements in the Liver Acinus MicroPhysiology System included improved performance of selected nonparenchymal cells, the inclusion of a porcine liver extracellular matrix to model the Space of Disse, as well as an improved media to support both hepatocytes and non-parenchymal cells. In its current form, the Liver Acinus MicroPhysiology System is most amenable to low to medium throughput, acute through chronic studies, including liver disease models, prioritizing compounds for preclinical studies, optimizing chemistry in structure activity relationship (SAR) projects, as well as in rising dose studies for initial dose ranging. Impact statement Oxygen zonation is a critical aspect of liver functions. A human microphysiology system is needed to investigate the impact of zonation on a wide range of liver functions that can be experimentally manipulated. Because oxygen zonation has such diverse physiological effects in the liver, we

  3. Oxygen Tension Regulates Human Mesenchymal Stem Cell Paracrine Functions.

    Science.gov (United States)

    Paquet, Joseph; Deschepper, Mickael; Moya, Adrien; Logeart-Avramoglou, Delphine; Boisson-Vidal, Catherine; Petite, Hervé

    2015-07-01

    : Mesenchymal stem cells (MSCs) have captured the attention and research endeavors of the scientific world because of their differentiation potential. However, there is accumulating evidence suggesting that the beneficial effects of MSCs are predominantly due to the multitude of bioactive mediators secreted by these cells. Because the paracrine potential of MSCs is closely related to their microenvironment, the present study investigated and characterized select aspects of the human MSC (hMSC) secretome and assessed its in vitro and in vivo bioactivity as a function of oxygen tension, specifically near anoxia (0.1% O2) and hypoxia (5% O2), conditions that reflect the environment to which MSCs are exposed during MSC-based therapies in vivo. In contrast to supernatant conditioned media (CM) obtained from hMSCs cultured at either 5% or 21% of O2, CM from hMSCs cultured under near anoxia exhibited significantly (p mesenchymal stem cell (hMSC) secretome and assessed its in vitro and in vivo biological bioactivity as a function of oxygen tension, specifically near anoxia (0.1% O2) and hypoxia (5% O2), conditions that reflect the environment to which MSCs are exposed during MSC-based therapies in vivo. The present study provided the first evidence of a shift of the hMSC cytokine signature induced by oxygen tension, particularly near anoxia (0.1% O2). Conditioned media obtained from hMSCs cultured under near anoxia exhibited significantly enhanced chemotactic and proangiogenic properties and a significant decrease in the inflammatory mediator content. These findings provide new evidence that elucidates aspects of great importance for the use of MSCs in regenerative medicine, could contribute to improving the efficacy of such therapies, and most importantly highlighted the interest in using conditioned media in therapeutic modalities. ©AlphaMed Press.

  4. Oxygen tension during biofilm growth influences the efficacy antimicrobial agents

    Directory of Open Access Journals (Sweden)

    Raquel Pippi ANTONIAZZI

    Full Text Available Abstract Objective To compare the antimicrobial efficacy of a 0.12% chlorhexidine (CHX and herbal green tea (Camellia sinensis solution on established biofilms formed at different oxygen tensions in an in situ model. Method Twenty-five dental students were eligible for the study. In situ devices with standardized enamel specimens (ES facing the palatal and buccal sides were inserted in the mouths of volunteers for a 7 day period. No agent was applied during the first four days. From the fifth day onward, both agents were applied to the test ES group and no agent was applied to the control ES group. After 7 days the ES fragments were removed from the devices, sonicated, plated on agar, and incubated for 24 h at 37 °C to determine and quantify the colony forming units (CFUs. Result CHX had significantly higher efficacy compared to green tea on the buccal (1330 vs. 2170 CFU/µL and palatal (2250 vs. 2520 CFU/µL ES. In addition, intragroup comparisons showed significantly higher efficacy in buccal ES over palatal ES (1330 vs. 2250 CFU/µL for CHX and 2170 vs, 2520 CFU/µL for CV for both solutions. Analysis of the ES controls showed significantly higher biofilm formation in palatal ES compared to buccal ES. Conclusion CHX has higher efficacy than green tea on 4-day biofilms. The efficacy of both agents was reduced for biofilms grown in a low oxygen tension environment. Therefore, the oxygen tension environment seems to influence the efficacy of the tested agents.

  5. Evaluation of multi-exponential curve fitting analysis of oxygen-quenched phosphorescence decay traces for recovering microvascular oxygen tension histograms

    NARCIS (Netherlands)

    Bezemer, Rick; Faber, Dirk J.; Almac, Emre; Kalkman, Jeroen; Legrand, Matthieu; Heger, Michal; Ince, Can

    2010-01-01

    Although it is generally accepted that oxygen-quenched phosphorescence decay traces can be analyzed using the exponential series method (ESM), its application until now has been limited to a few (patho)physiological studies, probably because the reliability of the recovered oxygen tension (pO(2))

  6. Low Oxygen Tension Enhances Expression of Myogenic Genes When Human Myoblasts Are Activated from G0 Arrest

    DEFF Research Database (Denmark)

    Sellathurai, Jeeva; Nielsen, Joachim; Hejbøl, Eva Kildall

    2016-01-01

    -PCR, immunocytochemistry and western blot. RESULTS AND CONCLUSIONS: We found an increase in proliferation rate of myoblasts when activated at a low oxygen tension (1% O2) compared to 21% O2. In addition, the gene expression studies showed up regulation of the myogenesis related genes PAX3, PAX7, MYOD, MYOG (myogenin), MET......, NCAM, DES (desmin), MEF2A, MEF2C and CDH15 (M-cadherin), however, the fraction of DES and MYOD positive cells was not increased by low oxygen tension, indicating that 1% O2 may not have a functional effect on the myogenic response. Furthermore, the expression of genes involved in the TGFβ, Notch...... and Wnt signaling pathways were also up regulated in low oxygen tension. The differences in gene expression were most pronounced at day one after activation from G0-arrest, thus the initial activation of myoblasts seemed most sensitive to changes in oxygen tension. Protein expression of HES1 and β...

  7. "Tissue oxygen tension, a determinant of resistance to infection and ...

    African Journals Online (AJOL)

    "Tissue oxygen tension, a determinant of resistance to infection and healing" - An Inaugural Lecture. K Jönsson. Abstract. An Inaugural Lecture Given in the University of Zimbabwe on 21 June 2001. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT.

  8. Cerebral interstitial tissue oxygen tension, pH, HCO3, CO2.

    Science.gov (United States)

    Charbel, F T; Hoffman, W E; Misra, M; Hannigan, K; Ausman, J I

    1997-10-01

    There are many techniques for monitoring the injured brain following trauma, subarachnoid hemorrhage, or surgery. It is thought that the major determinants for recovery of injured cerebral tissue are oxygen, glucose delivery, and the clearance of metabolites. These factors, at optimal levels, are probably responsible for the regaining of neuronal functions. These parameters are in turn dependent on the tissue's blood flow and metabolism. We have been using a single, compact, polyethylene sensor, the Paratrend 7 for the measurement of cerebral oxygen tension, CO2, pH, and temperature. This sensor is designed for continuous blood gas analysis to aid in monitoring neurosurgical patients, both during surgery and in the intensive care unit. Using the Paratrend 7 sensor, we found the normal range of values to be: PO2 33 +/- 11 mm Hg; PCO2 48 +/- 7 mm Hg; pH 7.19 +/- 0.11. Critical measurements are considered to be tissue PO2 60 mm Hg, and pH effective method of measuring tissue cerebral oxygen tension, along with carbon dioxide levels, pH, and temperature.

  9. Effect of body position and oxygen tension on foramen ovale recruitment.

    Science.gov (United States)

    Moses, Kayla L; Beshish, Arij G; Heinowski, Nicole; Baker, Kim R; Pegelow, David F; Eldridge, Marlowe W; Bates, Melissa L

    2015-01-01

    While there is an increased prevalence of stroke at altitude in individuals who are considered to be low risk for thrombotic events, it is uncertain how venous thrombi reach the brain. The patent foramen ovale (PFO) is a recruitable intracardiac shunt between the right and left atrium. We aimed to determine whether body position and oxygen tension affect blood flow through the PFO in healthy adults. We hypothesized that hypoxia and body positions that promote right atrial filling would independently recruit the PFO. Subjects with a PFO (n = 11) performed 11 trials, combining four different fractions of inhaled oxygen (FiO₂) (1.0, 0.21, 0.15, and 0.10) and three positions (upright, supine, and 45° head down), with the exception of FiO₂ = 0.10, while 45° head down. After 5 min in each position, breathing the prescribed oxygen tension, saline bubbles were injected into an antecubital vein and a four-chamber echocardiogram was obtained to evaluate PFO recruitment. We observed a high incidence of PFO recruitment in all conditions, with increased recruitment in response to severe hypoxia and some contribution of body position at moderate levels of hypoxia. We suspect that increased pulmonary vascular pressure, secondary to hypoxia-induced pulmonary vasoconstriction, increased right atrial pressure enough to recruit the PFO. Additionally, we hypothesize that the minor increase in breathing resistance that was added by the mouthpiece, used during experimental trials, affected intrathoracic pressure and venous return sufficiently to recruit the PFO. Copyright © 2015 the American Physiological Society.

  10. Effect of oxygen tension on bioenergetics and proteostasis in young and old myoblast precursor cells.

    Science.gov (United States)

    Konigsberg, M; Pérez, V I; Ríos, C; Liu, Y; Lee, S; Shi, Y; Van Remmen, H

    2013-01-01

    In the majority of studies using primary cultures of myoblasts, the cells are maintained at ambient oxygen tension (21% O2), despite the fact that physiological O2 at the tissue level in vivo is much lower (~1-5% O2). We hypothesized that the cellular response in presence of high oxygen concentration might be particularly important in studies comparing energetic function or oxidative stress in cells isolated from young versus old animals. To test this, we asked whether oxygen tension plays a role in mitochondrial bioenergetics (oxygen consumption, glycolysis and fatty acid oxidation) or oxidative damage to proteins (protein disulfides, carbonyls and aggregates) in myoblast precursor cells (MPCs) isolated from young (3-4 m) and old (29-30 m) C57BL/6 mice. MPCs were grown under physiological (3%) or ambient (21%) O2 for two weeks prior to exposure to an acute oxidative insult (H2O2). Our results show significantly higher basal mitochondrial respiration in young versus old MPCs, an increase in basal respiration in young MPCs maintained at 3% O2 compared to cells maintained at 21% O2, and a shift toward glycolytic metabolism in old MPCs grown at 21% O2. H2O2 treatment significantly reduced respiration in old MPCs grown at 3% O2 but did not further repress respiration at 21% O2 in old MPCs. Oxidative damage to protein was higher in cells maintained at 21% O2 and increased in response to H2O2 in old MPCs. These data underscore the importance of understanding the effect of ambient oxygen tension in cell culture studies, in particular studies measuring oxidative damage and mitochondrial function.

  11. Bladder urine oxygen tension for assessing renal medullary oxygenation in rabbits: experimental and modeling studies

    OpenAIRE

    Sgouralis, Ioannis; Kett, Michelle M.; Ow, Connie P. C.; Abdelkader, Amany; Layton, Anita T.; Gardiner, Bruce S.; Smith, David W.; Lankadeva, Yugeesh R.; Evans, Roger G.

    2016-01-01

    Oxygen tension (Po2) of urine in the bladder could be used to monitor risk of acute kidney injury if it varies with medullary Po2. Therefore, we examined this relationship and characterized oxygen diffusion across walls of the ureter and bladder in anesthetized rabbits. A computational model was then developed to predict medullary Po2 from bladder urine Po2. Both intravenous infusion of [Phe2,Ile3,Orn8]-vasopressin and infusion of NG-nitro-l-arginine reduced urinary Po2 and medullary Po2 (8–1...

  12. Unusual Growth Phase and Oxygen Tension Regulation of Oxidative Stress Protection Enzymes, Catalase and Superoxide Dismutase, in the Phytopathogen Xanthomonas oryzae pv. oryzae

    OpenAIRE

    Chamnongpol, S.; Mongkolsuk, S.; Vattanaviboon, P.; Fuangthong, M.

    1995-01-01

    The enzymes catalase and superoxide dismutase play major roles in protecting phytopathogenic bacteria from oxidative stress. In Xanthomonas species, these enzymes are regulated by both growth phase and oxygen tension. The highest enzyme levels were detected within 1 h of growth. Continued growth resulted in a decline of both enzyme activities. High oxygen tension was an inducing signal for both enzyme activities. An 80,000-Da monofunctional catalase and a manganese superoxide dismutase were t...

  13. Oxygen Tension Regulates Human Mesenchymal Stem Cell Paracrine Functions

    OpenAIRE

    Paquet, Joseph; Deschepper, Mickael; Moya, Adrien; Logeart-Avramoglou, Delphine; Boisson-Vidal, Catherine; Petite, Hervé

    2015-01-01

    This study examined the shift of the human mesenchymal stem cell (hMSC) cytokine signature induced by oxygen tension. Conditioned media obtained from hMSCs cultured under near anoxia exhibited significantly enhanced chemotactic and proangiogenic properties and a significant decrease in the inflammatory mediator content. These results elucidate important aspects of using MSCs in regenerative medicine, contribute to improving the efficacy of such therapies, and highlight the interest in using c...

  14. Radioprotection of mouse skin by WR-2721: the critical influence of oxygen tension

    International Nuclear Information System (INIS)

    Denekamp, J.; Michael, B.D.; Rojas, A.; Stewart, F.A.

    1982-01-01

    The epidermal clone assay has been used to study the radioprotective effect of WR-2721 on mouse skin under different conditions of oxygenation and under anoxia. The skin has shown a progressive decrease in sensitivity as the inspired gas has changed from 100% oxygen towards 0% oxygen. Compared with mice breathning 100% oxygen, those breathing air are partially protected. The inspired oxygen concentration to give half the full oxygen effect is 10-12%. The radioprotecton observed with 400 mg/kg WR-2721 is markedly dependent on the ambient oxygen concentration. The protection factor is 1.1 or less in mice breathing 5%, 1% or 0% oxygen. Protection is maximal (1.95) in air and in 50% oxygen and diminishes to 1.6 at higher oxygen tensions

  15. The Role of Oxygen Tension in Penile Erection and Its Relationship to Erectile Dysfunction

    Directory of Open Access Journals (Sweden)

    Jong-Kwan Park

    2004-01-01

    Full Text Available The corpus cavernosum of the penis is one of the few vascular beds in which there is a change in oxygen tension with function (blood PO2 25-40mm Hg in the flaccid state, and 90-100mm Hg in the erect state. This change in oxygen tension exposes the components of the corpus cavernosum to a variety of cytokines, humoral, vasoactive, and growth factors which may affect the structure and function of the endothelial cells, smooth muscle cells, neurons and extracellular matrix. Among these cell types, endothelial cells are the first line of defense to blood-borne stress and can affect the underlying smooth muscle via paracrine mechanisms. Impotence is defined as the inability to obtain or sustain an erection sufficient for vaginal penetration and can result from a variety of pathological conditions, vascular disease, endocrine disease, neurological disease, and psychogenic disorders. The penis is a vascular organ and as such is susceptible to the effects of vascular diseases. This review will discuss the basic etiology of erection and vasculogenic erectile dysfunction and explore the role oxygen tension in regulating various cellular and humoral factors as well as trabecular structure and function.

  16. Multiple oxygen tension environments reveal diverse patterns of transcriptional regulation in primary astrocytes.

    Directory of Open Access Journals (Sweden)

    Wayne Chadwick

    Full Text Available The central nervous system normally functions at O(2 levels which would be regarded as hypoxic by most other tissues. However, most in vitro studies of neurons and astrocytes are conducted under hyperoxic conditions without consideration of O(2-dependent cellular adaptation. We analyzed the reactivity of astrocytes to 1, 4 and 9% O(2 tensions compared to the cell culture standard of 20% O(2, to investigate their ability to sense and translate this O(2 information to transcriptional activity. Variance of ambient O(2 tension for rat astrocytes resulted in profound changes in ribosomal activity, cytoskeletal and energy-regulatory mechanisms and cytokine-related signaling. Clustering of transcriptional regulation patterns revealed four distinct response pattern groups that directionally pivoted around the 4% O(2 tension, or demonstrated coherent ascending/decreasing gene expression patterns in response to diverse oxygen tensions. Immune response and cell cycle/cancer-related signaling pathway transcriptomic subsets were significantly activated with increasing hypoxia, whilst hemostatic and cardiovascular signaling mechanisms were attenuated with increasing hypoxia. Our data indicate that variant O(2 tensions induce specific and physiologically-focused transcript regulation patterns that may underpin important physiological mechanisms that connect higher neurological activity to astrocytic function and ambient oxygen environments. These strongly defined patterns demonstrate a strong bias for physiological transcript programs to pivot around the 4% O(2 tension, while uni-modal programs that do not, appear more related to pathological actions. The functional interaction of these transcriptional 'programs' may serve to regulate the dynamic vascular responsivity of the central nervous system during periods of stress or heightened activity.

  17. Cerebral Microcirculation and Oxygen Tension in the Human Secondary Cortex

    Science.gov (United States)

    Linninger, A. A.; Gould, I. G.; Marinnan, T.; Hsu, C.-Y.; Chojecki, M.; Alaraj, A.

    2013-01-01

    The three-dimensional spatial arrangement of the cortical microcirculatory system is critical for understanding oxygen exchange between blood vessels and brain cells. A three-dimensional computer model of a 3 × 3 × 3 mm3 subsection of the human secondary cortex was constructed to quantify oxygen advection in the microcirculation, tissue oxygen perfusion, and consumption in the human cortex. This computer model accounts for all arterial, capillary and venous blood vessels of the cerebral microvascular bed as well as brain tissue occupying the extravascular space. Microvessels were assembled with optimization algorithms emulating angiogenic growth; a realistic capillary bed was built with space filling procedures. The extravascular tissue was modeled as a porous medium supplied with oxygen by advection–diffusion to match normal metabolic oxygen demand. The resulting synthetic computer generated network matches prior measured morphometrics and fractal patterns of the cortical microvasculature. This morphologically accurate, physiologically consistent, multi-scale computer network of the cerebral microcirculation predicts the oxygen exchange of cortical blood vessels with the surrounding gray matter. Oxygen tension subject to blood pressure and flow conditions were computed and validated for the blood as well as brain tissue. Oxygen gradients along arterioles, capillaries and veins agreed with in vivo trends observed recently in imaging studies within experimental tolerances and uncertainty. PMID:23842693

  18. Oxygen Exposure Resulting in Arterial Oxygen Tensions Above the Protocol Goal Was Associated With Worse Clinical Outcomes in Acute Respiratory Distress Syndrome.

    Science.gov (United States)

    Aggarwal, Neil R; Brower, Roy G; Hager, David N; Thompson, B Taylor; Netzer, Giora; Shanholtz, Carl; Lagakos, Adrian; Checkley, William

    2018-04-01

    High fractions of inspired oxygen may augment lung damage to exacerbate lung injury in patients with acute respiratory distress syndrome. Participants enrolled in Acute Respiratory Distress Syndrome Network trials had a goal partial pressure of oxygen in arterial blood range of 55-80 mm Hg, yet the effect of oxygen exposure above this arterial oxygen tension range on clinical outcomes is unknown. We sought to determine if oxygen exposure that resulted in a partial pressure of oxygen in arterial blood above goal (> 80 mm Hg) was associated with worse outcomes in patients with acute respiratory distress syndrome. Longitudinal analysis of data collected in these trials. Ten clinical trials conducted at Acute Respiratory Distress Syndrome Network hospitals between 1996 and 2013. Critically ill patients with acute respiratory distress syndrome. None. We defined above goal oxygen exposure as the difference between the fraction of inspired oxygen and 0.5 whenever the fraction of inspired oxygen was above 0.5 and when the partial pressure of oxygen in arterial blood was above 80 mm Hg. We then summed above goal oxygen exposures in the first five days to calculate a cumulative above goal oxygen exposure. We determined the effect of a cumulative 5-day above goal oxygen exposure on mortality prior to discharge home at 90 days. Among 2,994 participants (mean age, 51.3 yr; 54% male) with a study-entry partial pressure of oxygen in arterial blood/fraction of inspired oxygen that met acute respiratory distress syndrome criteria, average cumulative above goal oxygen exposure was 0.24 fraction of inspired oxygen-days (interquartile range, 0-0.38). Participants with above goal oxygen exposure were more likely to die (adjusted interquartile range odds ratio, 1.20; 95% CI, 1.11-1.31) and have lower ventilator-free days (adjusted interquartile range mean difference of -0.83; 95% CI, -1.18 to -0.48) and lower hospital-free days (adjusted interquartile range mean difference of -1.38; 95

  19. A method for volumetric retinal tissue oxygen tension imaging.

    Science.gov (United States)

    Felder, Anthony E; Wanek, Justin; Teng, Pang-Yu; Blair, Norman P; Shahidi, Mahnaz

    2018-01-01

    Inadequate retinal oxygenation occurs in many vision-threatening retinal diseases, including diabetic retinopathy, retinal vascular occlusions, and age-related macular degeneration. Therefore, techniques that assess retinal oxygenation are necessary to understand retinal physiology in health and disease. The purpose of the current study is to report a method for the three-dimensional (3D) imaging of retinal tissue oxygen tension (tPO 2 ) in rats. Imaging was performed in Long Evans pigmented rats under systemic normoxia (N = 6) or hypoxia (N = 3). A vertical laser line was horizontally scanned on the retina and a series of optical section phase-delayed phosphorescence images were acquired. From these images, phosphorescence volumes at each phase delay were constructed and a 3D retinal tPO 2 volume was generated. Retinal tPO 2 volumes were quantitatively analyzed by generating retinal depth profiles of mean tPO 2 (M tPO2 ) and the spatial variation of tPO 2 (SV tPO2 ). The effects of systemic condition (normoxia/hypoxia) and retinal depth on M tPO2 and SV tPO2 were determined by mixed linear model. Each 3D retinal tPO 2 volume was approximately 500 × 750 × 200 μm (horizontal × vertical × depth) and consisted of 45 en face tPO 2 images through the retinal depth. M tPO2 at the chorioretinal interface was significantly correlated with systemic arterial oxygen tension (P = 0.007; N = 9). There were significant effects of both systemic condition and retinal depth on M tPO2 and SV tPO2 , such that both were lower under hypoxia than normoxia and higher in the outer retina than inner retina (P < 0.001). For the first time, 3D imaging of retinal tPO 2 was demonstrated, with potential future application for assessment of physiological alterations in animal models of retinal diseases.

  20. Enhanced dopaminergic differentiation of human neural stem cells by synergistic effect of Bcl-xL and reduced oxygen tension

    DEFF Research Database (Denmark)

    Krabbe, Christina; Courtois, Elise; Jensen, Pia

    2009-01-01

    Neural stem cells constitute a promising source of cells for transplantation in Parkinson's disease, but a protocol for controlled dopaminergic differentiation is not yet available. Here we investigated the effect of the anti-apoptotic protein Bcl-x(L) and oxygen tension on dopaminergic different......Neural stem cells constitute a promising source of cells for transplantation in Parkinson's disease, but a protocol for controlled dopaminergic differentiation is not yet available. Here we investigated the effect of the anti-apoptotic protein Bcl-x(L) and oxygen tension on dopaminergic...... days at 20% oxygen, hVMbcl-x(L) cultures contained proportionally more tyrosine hydroxylase(TH)-positive cells than hVM1 control cultures. This difference was significantly potentiated from 11 +/- 0.8% to 17.2 +/- 0.2% of total cells when the oxygen tension was lowered to 3%. Immunocytochemistry and Q...

  1. Influence of hyperoxia on the number of nucleated cells and oxygen tension in rat bone marrow after whole-body irradiation

    International Nuclear Information System (INIS)

    Zima, M.; Vodicka, I.

    1987-01-01

    The cell number in the femur bone marrow of rats determined three days after X-ray or gamma irradiation is inversely proportional to the dose while oxygen tension in the marrow shows direct dependence on the dose. With fractionation of the lethal dose of gamma radiation (9 Gy) into two doses with different time intervals between them, a greater number of bone marrow cells and a smaller oxygen tension are reached on the 3rd day after the second dose, reflecting the extent of bone marrow repair. A short-term hyperoxia (95% O 2 + 5% CO 2 ) lasting 20 min from the end of exposure compared with the euoxic conditions induced, on the 3rd day after the second fraction, a nonsignificant but reproducible increase in the marrow cell number and a decrease in partial oxygen tension in the distal part of femur marrow. The results obtained testify that immediate short-term hyperoxia facilitates regeneration of the marrow and that a greater number of cells accompanied by greater metabolic activity and oxygen consumption decrease the partial oxygen tension measured on the 3rd day following the last exposure. (author). 7 figs., 16 refs

  2. Indomethacin lowers optic nerve oxygen tension and reduces the effect of carbonic anhydrase inhibition and carbon dioxide breathing

    DEFF Research Database (Denmark)

    Pedersen, D B; Eysteinsson, T; Stefánsson, E

    2004-01-01

    Prostaglandins are important in blood flow regulation. Carbon dioxide (CO(2)) breathing and carbonic anhydrase inhibition increase the oxygen tension in the retina and optic nerve. To study the mechanism of this effect and the role of cyclo-oxygenase in the regulation of optic nerve oxygen tension...... (ONPO(2)), the authors investigated how indomethacin affects ONPO(2) and the ONPO(2) increases caused by CO(2) breathing and carbonic anhydrase inhibition in the pig....

  3. Microcomputer-based system for registration of oxygen tension in peripheral muscle.

    Science.gov (United States)

    Odman, S; Bratt, H; Erlandsson, I; Sjögren, L

    1986-01-01

    For registration of oxygen tension fields in peripheral muscle a microcomputer based system was designed on the M6800 microprocessor. The system was designed to record the signals from a multiwire oxygen electrode, MDO, which is a multiwire electrode for measuring oxygen on the surface of an organ. The system contained patient safety isolation unit built on optocopplers and the upper frequency limit was 0.64 Hz. Collected data were corrected for drift and temperature changes during the measurement by using pre- and after calibrations and a linear compensation technique. Measure drift of the electrodes were proved to be linear and thus the drift could be compensated for. The system was tested in an experiment on pig. To study the distribution of oxygen statistically mean, standard deviation, skewness and curtosis were calculated. To see changes or differences between histograms a Kolmogorv-Smirnov test was used.

  4. [Effect of different oxygen tension on the cytoskeleton remodeling of goat temporomandibular joint disc cells].

    Science.gov (United States)

    Xiaolan, He; Guangjie, Bao; Linglu, Sun; Xue, Zhang; Shanying, Bao; Hong, Kang

    2017-08-01

    Objective The effect of different oxygen tensions on the cytoskeleton remodeling of goat temporomandibular joint (TMJ) disc cells were investigated. Methods Goat TMJ disc cells were cultured under normoxia (21% O₂) and hypoxia (2%, 4%, and 8% O₂). Toluidine blue, picrosirius red, and type Ⅰ collagen immunocytochemical staining were performed to observe the changes in cell phenotype under different oxygen levels. Immunofluorescent staining and real-time reverse transcription-polymerase chain reaction analysis were then performed to identify actin, tubulin, and vimentin in the cultured disc cells. Results TMJ disc cells still displayed fibroblast characteristics under different oxygen levels and their cytoskeletons had regular arrangement. The fluorescence intensities of actin and vimentin were lowest at 4% O₂(P0.05). Actin mRNA levels were considerably decreased at 2% O₂ and 4% O₂ in hypoxic conditions, while actin mRNA expression was highest in 21% O₂. Tubulin mRNA levels considerably increased at 2% O₂, while tubulin mRNA expression was lowest in 8% O₂ (Plevels among these oxygen levels (Poxygen tensions, and 2% O₂ may be the optimal oxygen level required to proliferate TMJ disc cells.

  5. Oxidative stress under ambient and physiological oxygen tension in tissue culture

    Science.gov (United States)

    Jagannathan, Lakshmanan; Cuddapah, Suresh; Costa, Max

    2016-01-01

    Oxygen (O2) levels range from 2–9% in vivo. However, cell culture experiments are performed at atmospheric O2 levels (21%). Oxidative stress due to generation of reactive oxygen species (ROS) in cells cultured at higher than physiological levels is implicated in multitude of deleterious effects including DNA damage, genomic instability and senescence. In addition, oxidative stress activates redox sensitive transcription factors related to inflammatory signaling and apoptotic signaling. Furthermore, several chromatin-modifying enzymes are affected by ROS, potentially impacting epigenetic regulation of gene expression. While primary cells are cultured at lower O2 levels due to their inability to grow at higher O2, the immortalized cells, which display no such apparent growth difficulties, are typically cultured at 21% O2. This review will provide an overview of issues associated with increased oxygen levels in in vitro cell culture and point out the benefits of using lower levels of oxygen tension even for immortalized cells. PMID:27034917

  6. Characterization and validation of noninvasive oxygen tension measurements in human glioma xenografts by 19F-MR relaxometry

    International Nuclear Information System (INIS)

    Sanden, Boudewijn P.J. van der; Heerschap, Arend; Simonetti, Arjan W.; Rijken, Paul F.J.W.; Peters, Hans P.W.; Stbeen, Georg; Kogel, Albert J. van der

    1999-01-01

    Purpose: The aim of this study was to characterize and to validate noninvasive 19 F-magnetic resonance relaxometry for the measurement of oxygen tensions in human glioma xenografts in nude mice. The following three questions were addressed: 1. When perfluorocarbon compounds (PFCs) are administrated intravenously, which tumor regions are assessed by 19 F-MR relaxometry? 2. Are oxygen tension as detected by 19 F-MR relaxometry (pO 2/relaxo ) comparable to Eppendorf O 2 -electrode measurements (pO 2/electrode )? 3. Can 19 F-MR relaxometry be used to detect oxygen tension changes in tumor tissue during carbogen breathing? Methods and Materials: Slice-selective 19 F-MR relaxometry was carried out with perfluoro-15-crown-5-ether as oxygen sensor. The PFC was injected i.v. 3 days before the 19 F-MR experiments. Two datasets were acquired before and two after the start of carbogen breathing. The distribution of PFCs and necrotic areas were analyzed in 19 F-Spin Echo (SE) density MR images and T 2 -weighted 1 H-SE MR images, respectively. One day after the MR investigations, oxygen tensions were measured by oxygen electrodes in the same slice along two perpendicular tracks. These measurements were followed by (immuno)histochemical analysis of the 2D distribution of perfused microvessels, hypoxic cells, necrotic areas, and macrophages. Results: The PFCs mainly became sequestered in perfused regions at the tumor periphery; thus, 19 F-MR relaxometry probed mean oxygen tensions in these regions throughout the selected MR slice. In perfused regions of the tumor, mean pO 2/relaxo values were comparable to mean pO 2/electrode values, and varied from 0.03 to 9 mmHg. Median pO 2/electrode values of both tracks were lower than mean pO 2/relaxo values, because low pO 2/electrode values that originate from hypoxic and necrotic areas were also included in calculations of median pO 2/electrode values. After 8-min carbogen breathing, the average pO 2/relaxo increase was 3.3 ± 0.8 (SEM

  7. Oxygen tension regulates the osteogenic, chondrogenic and endochondral phenotype of bone marrow derived mesenchymal stem cells

    Energy Technology Data Exchange (ETDEWEB)

    Sheehy, Eamon J.; Buckley, Conor T. [Trinity Centre for Bioengineering, School of Engineering, Trinity College Dublin, Dublin 2 (Ireland); Kelly, Daniel J., E-mail: kellyd9@tcd.ie [Trinity Centre for Bioengineering, School of Engineering, Trinity College Dublin, Dublin 2 (Ireland)

    2012-01-06

    Highlights: Black-Right-Pointing-Pointer Expansion in low oxygen enhances MSC proliferation and osteogenesis. Black-Right-Pointing-Pointer Differentiation in low oxygen enhances chondrogenesis and suppresses hypertrophy. Black-Right-Pointing-Pointer Oxygen can regulate the MSC phenotype for use in tissue engineering applications. -- Abstract: The local oxygen tension is a key regulator of the fate of mesenchymal stem cells (MSCs). The objective of this study was to investigate the effect of a low oxygen tension during expansion and differentiation on the proliferation kinetics as well as the subsequent osteogenic and chondrogenic potential of MSCs. We first hypothesised that expansion in a low oxygen tension (5% pO{sub 2}) would improve both the subsequent osteogenic and chondrogenic potential of MSCs compared to expansion in a normoxic environment (20% pO{sub 2}). Furthermore, we hypothesised that chondrogenic differentiation in a low oxygen environment would suppress hypertrophy of MSCs cultured in both pellets and hydrogels used in tissue engineering strategies. MSCs expanded at 5% pO{sub 2} proliferated faster forming larger colonies, resulting in higher cell yields. Expansion at 5% pO{sub 2} also enhanced subsequent osteogenesis of MSCs, whereas differentiation at 5% pO{sub 2} was found to be a more potent promoter of chondrogenesis than expansion at 5% pO{sub 2}. Greater collagen accumulation, and more intense staining for collagen types I and X, was observed in pellets maintained at 20% pO{sub 2} compared to 5% pO{sub 2}. Both pellets and hydrogels stained more intensely for type II collagen when undergoing chondrogenesis in a low oxygen environment. Differentiation at 5% pO{sub 2} also appeared to inhibit hypertrophy in both pellets and hydrogels, as demonstrated by reduced collagen type X and Alizarin Red staining and alkaline phosphatase activity. This study demonstrates that the local oxygen environment can be manipulated in vitro to either stabilise a

  8. Methyl sterol and cyclopropane fatty acid composition of Methylococcus capsulatus grown at low oxygen tensions

    Science.gov (United States)

    Jahnke, L. L.; Nichols, P. D.

    1986-01-01

    The sterol and fatty acid concentrations for M. capsulatus grown in fed-batch cultures over a wide range of oxygen tensions (0.1-10.6 percent) and at a constant methane level are evaluated. The analyses reveal that the biomass decreases as oxygen levels are lowered; the sterol concentration increases when the oxygen range is between 0.5-1.1 percent and decreases when the oxygen range is below 0.5 percent; and the amount of monounsaturated C16 decreases and the concentration of cyclopropane fatty acids increases after oxygen is reduced. It is noted that growth and membrane synthesis occur at low oxygen concentrations and that the synthesis of membrane lipids responds to growth conditions.

  9. Indomethacin decreases optic nerve oxygen tension by a mechanism other than cyclo-oxygenase inhibition

    DEFF Research Database (Denmark)

    Noergaard, M Hove; Pedersen, D Bach; Bang, K

    2008-01-01

    We investigated the effect of several Non-Steroidal Anti-Inflammatory Drugs (NSAIDs), on the preoptic nerve oxygen tension (ONPO2), as indomethacin previously has demonstrated a strong decreasing effect on ONPO2. We tested whether these NSAIDs, like indomethacin, also reduce the increasing effect...

  10. Matrix forming characteristics of inner and outer human meniscus cells on 3D collagen scaffolds under normal and low oxygen tensions.

    Science.gov (United States)

    Croutze, Roger; Jomha, Nadr; Uludag, Hasan; Adesida, Adetola

    2013-12-13

    Limited intrinsic healing potential of the meniscus and a strong correlation between meniscal injury and osteoarthritis have prompted investigation of surgical repair options, including the implantation of functional bioengineered constructs. Cell-based constructs appear promising, however the generation of meniscal constructs is complicated by the presence of diverse cell populations within this heterogeneous tissue and gaps in the information concerning their response to manipulation of oxygen tension during cell culture. Four human lateral menisci were harvested from patients undergoing total knee replacement. Inner and outer meniscal fibrochondrocytes (MFCs) were expanded to passage 3 in growth medium supplemented with basic fibroblast growth factor (FGF-2), then embedded in porous collagen type I scaffolds and chondrogenically stimulated with transforming growth factor β3 (TGF-β3) under 21% (normal or normoxic) or 3% (hypoxic) oxygen tension for 21 days. Following scaffold culture, constructs were analyzed biochemically for glycosaminoglycan production, histologically for deposition of extracellular matrix (ECM), as well as at the molecular level for expression of characteristic mRNA transcripts. Constructs cultured under normal oxygen tension expressed higher levels of collagen type II (p = 0.05), aggrecan (p oxygen tension. There was no significant difference in expression of these genes between scaffolds seeded with MFCs isolated from inner or outer regions of the tissue following 21 days chondrogenic stimulation (p > 0.05). Cells isolated from inner and outer regions of the human meniscus demonstrated equivalent differentiation potential toward chondrogenic phenotype and ECM production. Oxygen tension played a key role in modulating the redifferentiation of meniscal fibrochondrocytes on a 3D collagen scaffold in vitro.

  11. Multibreath alveolar oxygen tension imaging.

    Science.gov (United States)

    Clapp, Justin; Hamedani, Hooman; Kadlecek, Stephen; Xin, Yi; Shaghaghi, Hoora; Siddiqui, Sarmad; Rossman, Milton D; Rizi, Rahim R

    2016-10-01

    This study tested the ability of a multibreath hyperpolarized HP (3) He MRI protocol to increase the accuracy of regional alveolar oxygen tension (PA O2 ) measurements by lessening the influence of gas-flow artifacts. Conventional single-breath PA O2 measurement has been susceptible to error induced by intervoxel gas flow, particularly when used to study subjects with moderate-to-severe chronic obstructive pulmonary disease (COPD). Both single-breath and multibreath PA O2 imaging schemes were implemented in seven human subjects (one healthy, three asymptomatic smokers, and three COPD). The number and location of voxels with nonphysiologic PA O2 values generated by intervoxel gas flow were compared between the two protocols. The multibreath scheme resulted in a significantly lower total percentage of nonphysiologic PA O2 values (6.0%) than the single-breath scheme (13.7%) (P = 0.006). PA O2 maps showed several patterns of gas-flow artifacts that were present in the single-breath protocol but mitigated by the multibreath approach. Multibreath imaging also allowed for the analysis of slow-filling areas that presented no signal after a single breath. A multibreath approach enhances the accuracy and completeness of noninvasive PA O2 measurement by significantly lessening the proportion of nonphysiologic values generated by intervoxel gas flow. Magn Reson Med 76:1092-1101, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  12. The relationship between alveolar oxygen tension and the single-breath carbon monoxide diffusing capacity.

    Science.gov (United States)

    Kanner, R E; Crapo, R O

    1986-04-01

    The effects of alveolar oxygen tension (PAO2) on the single-breath carbon monoxide diffusing capacity (DLCO) were quantified and a factor was derived to accommodate for differences in PAO2 over commonly encountered altitudes and/or varying concentrations of oxygen in the test gas mixture (FIO2) We performed duplicate measurements of DLCO in 7 normal subjects with 6 different oxygen fractions (0.176, 0.196, 0.211, 0.22, 0.25, and 0.27). The PAO2 for each test was measured as the PO2 in the alveolar gas sample bag. DLCO varied inversely with PAO2 and changed by 0.35% for each mmHg change in PAO2 (r = -0.62, p less than 0.001). At an FIO2 of 0.25, PAO2 varied between subjects and was highly correlated with each subject's residual volume to total lung capacity ratio (r = -0.84, p less than 0.001). We suggest that laboratories can adjust the measured DLCO when PAO2 is not congruent to 120 mmHg by the following formula: DLCO (corrected = DLCO (measured) x [1.0 + 0.0035 (PAO2 - 120)].

  13. BIOELECTRIC POTENTIALS IN HALICYSTIS : VII. THE EFFECTS OF LOW OXYGEN TENSION.

    Science.gov (United States)

    Blinks, L R; Darsie, M L; Skow, R K

    1938-11-20

    The potential difference across the protoplasm of impaled cells of Halicystis is not affected by increase of oxygen tension in equilibrium with the sea water, nor with decrease down to about 1/10 its tension in the air (2 per cent O(2) in N(2)). When bubbling of 2 per cent O(2) is stopped, the P.D. drifts downward, to be restored on stirring the sea water, or rebubbling the gas. Bubbling 0.2 per cent O(2) causes the P.D. to drop to 20 mv. or less; 1.1 per cent O(2) to about 50 mv. Restoration of 2 per cent or higher O(2) causes recovery to 70 or 80 mv. often with a preliminary cusp which decreases the P.D. before it rises. Perfusion of aerated sea water through the vacuole is just as effective in restoring the P.D. as external aeration, indicating that the direction of the oxygen gradient is not significant. Low O(2) tension also inhibits the reversed, negative P.D. produced by adding NH(4)Cl to sea water, 0.2 per cent O(2) bringing this P.D. back to the same low positive values found without ammonia. Restoration of 2 per cent O(2) or air, restores this latent negativity. At slightly below the threshold for ammonia reversal, low O(2) may induce a temporary negativity when first bubbled, and a negative cusp may occur on aeration before positive P.D. is regained. This may be due to a decreased consumption of ammonia, or to intermediate pH changes. The locus of the P.D. alteration was tested by applying increased KCl concentrations to the cell exterior; the large cusps produced in aerated solutions become greatly decreased when the P.D. has fallen in 0.2 per cent O(2). This indicates that the originally high relative mobility or concentration of K(+) ion has approached that of Na(+) in the external protoplasmic surface under reduced O(2) tension. Results obtained with sulfate sea water indicate that Na(+) mobility approaches that of SO(4) (-) in 0.2 per cent O(2). P.D. measurements alone cannot tell whether this is due to an increase of the slower ion or a decrease of

  14. Oxygen Tension Beneath Scleral Lenses of Different Clearances.

    Science.gov (United States)

    Giasson, Claude J; Morency, Jeanne; Melillo, Marc; Michaud, Langis

    2017-04-01

    To evaluate the relative partial pressure in oxygen (pO2) at the corneal surface under Boston XO2 scleral lenses (SL) fitted with targeted clearances of 200 and 400 μm (SL200 and SL400). During this prospective study, the right eyes of eight normal subjects were fitted with SL200 and SL400. Clearance, validated after 5 minutes of wear with an optical coherence tomograph, was used with lens thicknesses to calculate transmissibility and estimate pO2. Corneal pO2s were measured with an oxygen electrode after 5 minutes of (1) corneal exposure to calibrating gases with various pO2 or of (2) SL wear. Decays in pO2 were modeled to an exponential. Linear regression between exponent k of these decays and calibrating gas pO2s allowed for the calculation of corneal pO2 under SL. Differences between pO2s beneath SL200 and SL400 were tested with a mixed ANOVA. The estimated transmissibility based on thicknesses and clearances (239.7 ± 34.7; 434.5 ± 33.2 μm) predicted a corneal pO2 of 8.52 ± 0.51 and 6.37 ± 0.28% for SL200 and SL400. These values were close to measured pO2: 9.07 ± 0.86 and 6.19 ± 0.87% (mean ± SEM) (P time, an 18-mm scleral lens fitted with a 400-μm clearance reduces the oxygen tension available to the cornea by 30% compared to a similar lens fitted with a 200-μm clearance after 5 minutes of wear.

  15. Measuring oxygen tension modulation, induced by a new pre-radiotherapy therapeutic, in a mammary window chamber mouse model

    Science.gov (United States)

    Schafer, Rachel; Gmitro, Arthur F.

    2015-03-01

    Tumor regions under hypoxic or low oxygen conditions respond less effectively to many treatment strategies, including radiation therapy. A novel investigational therapeutic, NVX-108 (NuvOx Pharma), has been developed to increase delivery of oxygen through the use of a nano-emulsion of dodecofluoropentane. By raising pO2 levels prior to delivering radiation, treatment efficacy may be improved. To aid in evaluating the novel drug, oxygen tension was quantitatively measured, spatially and temporally, to record the effect of administrating NVX-108 in an orthotopic mammary window chamber mouse model of breast cancer. The oxygen tension was measured through the use of an oxygen-sensitive coating, comprised of phosphorescent platinum porphyrin dye embedded in a polystyrene matrix. The coating, applied to the surface of the coverslip of the window chamber through spin coating, is placed in contact with the mammary fat pad to record the oxygenation status of the surface tissue layer. Prior to implantation of the window chamber, a tumor is grown in the SCID mouse model by injection of MCF-7 cells into the mammary fat pad. Two-dimensional spatial distributions of the pO2 levels were obtained through conversion of measured maps of phosphorescent lifetime. The resulting information on the spatial and temporal variation of the induced oxygen modulation could provide valuable insight into the optimal timing between administration of NVX-108 and radiation treatment to provide the most effective treatment outcome.

  16. Oxygen tension and prediction of the radiation response. Polarographic study in human breast cancer

    International Nuclear Information System (INIS)

    Pappova, N.; Siracka, E.

    1982-01-01

    Serial polarographic measurement of the tissue oxygen tension (pO 2 ) was made in the course of fractionated irradiation (preoperative or sole treatment) of advanced breast cancer in 24 patients. In responsive tumors an increase in pO 2 appeared sooner before expressive tumor size reduction became noticeable. Repeated recording of unchanged pO 2 values proved to be a good prognostic indicator of local failure. The study made on this tumor model showed that serial polarographic pO 2 determinations with suitable electrodes causing minimal trauma and providing consistent and reproductive data about changes in tumor microcirculation and oxygenation may enlarge the scale of indicators of radiation response. (author)

  17. The role of tissue oxygen tension in the control of local blood flow in the microcirculation of skeletal muscles

    DEFF Research Database (Denmark)

    Ngo, Thuc Anh

    2010-01-01

    In the microcirculation blood flow is highly regulated dependent on the metabolic activity of the tissues. Among several mechanisms, mechanisms involved in the coupling of changes in tissue oxygen tension due to changes in the metabolic activity of the tissue play an important role. In the systemic...... (inhibitor of KATP channels) in the superfusate abolished both vasodilatation and constriction to low and high oxygen superfusate, indicating that KATP channels are involved in both hypoxic vasodilatation and hyperoxic vasoconstriction. Red blood cells (RBCs) have been proposed to release ATP and...... as in the intact blood-perfused arteriole. This indicates that RBCs are not essential for hypoxic vasodilatation. In addition several potential pathways were evaluated. Application of DPCPX (inhibitor of adenosine A1 and A2 receptors) and L-NAME (inhibitor of NO-synthase) did not affect vasomotor responses to low...

  18. Oxygen sensing and conducted vasomotor responses in mouse cremaster arterioles in situ

    DEFF Research Database (Denmark)

    Ngo, Thuc Anh; Jensen, Lars Jørn; Riemann, Mads Achen

    2010-01-01

    .0 +/- 4.9 mum) when changing from high (PO(2) = 242.5 +/- 13.3 mm Hg) to low (PO(2) = 22.5 +/- 4.8 mm Hg) oxygen tension as seen in the intact cremaster circulation (DeltaD = 18.7 +/- 1.0 mum). Blockade of NO synthases by L: -NAME and adenosine receptors by DPCPX had no effects on vasomotor responses...... to low or high oxygen. Induction of localized low (PO(2) = 23.3 +/- 5.7 mmHg) or high (PO(2) = 300.0 +/- 25.7 mm Hg) oxygen tension caused vasodilatation or -constriction locally and at a site 1,000 mum upstream (distantly). Glibenclamide blocker of ATP-sensitive K(+) channels inhibited vasodilatation...... and -constriction to low (PO(2) = 16.0 +/- 6.4 mm Hg) and high (PO(2) = 337.4 +/- 12.8 mm Hg) oxygen tension. 1) ATP-sensitive K(+) channels seem to mediate, at least in part, vasodilatation and vasoconstriction to low and high oxygen tension; 2) Red blood cells are not necessary for inducing vasodilatation...

  19. Adverse effects of reduced oxygen tension on the proliferative capacity of rat kidney and insulin-secreting cell lines involve DNA damage and stress responses

    International Nuclear Information System (INIS)

    Chen Jianhua; Jones, R. Huw; Tarry-Adkins, Jane; Smith, Noel H.; Ozanne, Susan E.

    2008-01-01

    Standard cell culture conditions do not reflect the physiological environment in terms of oxygen tension (20% vs 3%). The effects of lowering oxygen tension on cell proliferation in culture can be beneficial as well as detrimental depending on the cell line studied, but the molecular mechanism underlying such effects is not fully understood. We observed that the proliferative capacity of the rat cell lines NRK and INS-1 was inhibited when cultured under 3% oxygen as compared to 20% oxygen. Suppression of proliferation in NRK cells was accompanied by induction of DNA double strand breaks whereas in INS-1 cells it was accompanied by up-regulation of p53 and p27. Although Sirt1 was up-regulated in both cell lines by 3% oxygen the effects on antioxidant enzymes (MnSOD, CuZnSOD and catalase) were cell line specific. Marked up-regulation of heme oxygenase-1 (HO-1) was detected in both NRK and INS-1 cells when cultured in 3% oxygen. HO-1 expression can be readily induced by exposure to hydrogen peroxide in culture. These results suggest that reduced oxygen tension suppresses the proliferative capacity of these two cell lines through a stress response that is similar to an oxidative stress response but the molecular events that lead to the reduced cell proliferation are cell line specific

  20. Experimental studies on radiation effects under high pressure oxygen

    Energy Technology Data Exchange (ETDEWEB)

    Fujimura, E [Osaka Univ. (Japan). School of Dentistry

    1974-06-01

    The effect of oxygen tension on the radiosensitivity of tumor cells is well known, but its clinical application for radiotherapy is not yet established. Rabbits with V x 2 carcinoma in the maxilla were irradiated by /sup 60/Co under high pressure oxygen (experimental group), and compared with those treated in air (control group). For the purpose of examining the clinical effects of high pressure oxygen, an experiment was made in vivo. The following items were compared respectively: a) Tumor regression effect b) Tumor clearance rate c) Survival days d) Half size reduction time e) Inhibition of DNA synthesis in the tumor tissue. Results obtained were as follows: a) 56 per cent of animals showed tumor regression in the experimental group, whereas it occured 26 per cent in the control group. b) 53 per cent of animals showed tumor disappearance in the experimental group, while it was observed only in 13 per cent in the control group. c) Only 2 of 30 rabbits irradiated in air survived over 180 days, whereas 11 of 30 rabbits survived meanwhile in the group irradiated under high pressure oxygen. d) About 11 days were necessary to reduce the tumor size by half after irradiation in the group under high pressure oxygen, while it took 17 days in the group treated in normal air. e) DNA synthesis was inhibited more prominently in the group irradiated under high pressure oxygen in normal air.

  1. Oxygen tension is a determinant of the matrix-forming phenotype of cultured human meniscal fibrochondrocytes.

    Directory of Open Access Journals (Sweden)

    Adetola B Adesida

    Full Text Available BACKGROUND: Meniscal cartilage displays a poor repair capacity, especially when injury is located in the avascular region of the tissue. Cell-based tissue engineering strategies to generate functional meniscus substitutes is a promising approach to treat meniscus injuries. Meniscus fibrochondrocytes (MFC can be used in this approach. However, MFC are unable to retain their phenotype when expanded in culture. In this study, we explored the effect of oxygen tension on MFC expansion and on their matrix-forming phenotype. METHODOLOGY/PRINCIPAL FINDINGS: MFC were isolated from human menisci followed by basic fibroblast growth factor (FGF-2 mediated cell expansion in monolayer culture under normoxia (21%O(2 or hypoxia (3%O(2. Normoxia and hypoxia expanded MFC were seeded on to a collagen scaffold. The MFC seeded scaffolds (constructs were cultured in a serum free chondrogenic medium for 3 weeks under normoxia and hypoxia. Constructs containing normoxia-expanded MFC were subsequently cultured under normoxia while those formed from hypoxia-expanded MFC were subsequently cultured under hypoxia. After 3 weeks of in vitro culture, the constructs were assessed biochemically, histologically and for gene expression via real-time reverse transcription-PCR assays. The results showed that constructs under normoxia produced a matrix with enhanced mRNA ratio (3.5-fold higher; p<0.001 of collagen type II to I. This was confirmed by enhanced deposition of collagen II using immuno-histochemistry. Furthermore, the constructs under hypoxia produced a matrix with higher mRNA ratio of aggrecan to versican (3.5-fold, p<0.05. However, both constructs had the same capacity to produce a glycosaminoglycan (GAG -specific extracellular matrix. CONCLUSIONS: Our data provide evidence that oxygen tension is a key player in determining the matrix phenotype of cultured MFC. These findings suggest that the use of normal and low oxygen tension during MFC expansion and subsequent neo

  2. Exogenous and endogenous angiotensin-II decrease renal cortical oxygen tension in conscious rats by limiting renal blood flow

    NARCIS (Netherlands)

    Emans, Tonja W.; Janssen, Ben J.; Pinkham, Maximilian I.; Ow, Connie P. C.; Evans, Roger G.; Joles, Jaap A.; Malpas, Simon C.; Krediet, C. T. Paul; Koeners, Maarten P.

    2016-01-01

    Our understanding of the mechanisms underlying the role of hypoxia in the initiation and progression of renal disease remains rudimentary. We have developed a method that allows wireless measurement of renal tissue oxygen tension in unrestrained rats. This method provides stable and continuous

  3. Effect of supplemental oxygen versus dobutamine administration on liver oxygen tension in dPP-guided normovolemic pigs.

    Science.gov (United States)

    Pestel, G; Fukui, K; Hager, H; Kurz, A; Hiltebrand, L

    2009-01-01

    Difference in pulse pressure (dPP) confirms adequate intravascular filling as a prerequisite for tissue perfusion. We hypothesized that both oxygen and dobutamine increase liver tissue oxygen tension (ptO(2)). Eight anesthetized pigs received dPP-guided fluid management. Hepatic pO(2) was measured with Clark-type electrodes placed subcapsularly, and on the liver surface. Pigs received: (1) supplemental oxygen (F(i)O(2) 1.0); (2) dobutamine 2.5 microg/kg/min, and (3) dobutamine 5 microg/kg/min. Data were analyzed using repeated-measures ANOVA followed by a Tukey post-test for multiple comparisons. ptO(2 )measured subcapsularly and at the liver surface were compared using the Bland-Altman plot. Variation in F(i)O(2) changed local hepatic tissue ptO(2) [subcapsular measurement: 39 +/- 12 (F(i)O(2) 0.3), 89 +/- 35 mm Hg (F(i)O(2) 1.0, p = 0.01 vs. F(i)O(2) 0.3), 44 +/- 10 mm Hg (F(i)O(2) 0.3, p = 0.05 vs. F(i)O(2) 1.0); surface measurement: 52 +/- 35 (F(i)O(2) 0.3), 112 +/- 24 mm Hg (F(i)O(2) 1.0, p = 0.001 vs. F(i)O(2) 0.3), 54 +/- 24 mm Hg (F(i)O(2) 0.3, p = 0.001 vs. F(i)O(2) 1.0)]. Surface measurements were widely scattered compared to subcapsular measurements (bias: -15 mm Hg, precision: 76.3 mm Hg). Dobutamine did not affect hepatic oxygenation. Supplemental oxygen increased hepatic tissue pO(2) while dobutamine did not. Although less invasive, the use of surface measurements is discouraged. Copyright 2009 S. Karger AG, Basel.

  4. Reactive oxygen species-driven HIF1α triggers accelerated glycolysis in endothelial cells exposed to low oxygen tension

    International Nuclear Information System (INIS)

    Paik, Jin-Young; Jung, Kyung-Ho; Lee, Jin-Hee; Park, Jin-Won; Lee, Kyung-Han

    2017-01-01

    Endothelial cells and their metabolic state regulate glucose transport into underlying tissues. Here, we show that low oxygen tension stimulates human umbilical vein endothelial cell 18 F–fluorodeoxyglucose ( 18 F–FDG) uptake and lactate production. This was accompanied by augmented hexokinase activity and membrane Glut-1, and increased accumulation of hypoxia-inducible factor-1α (HIF1α). Restoration of oxygen reversed the metabolic effect, but this was blocked by HIF1α stabilization. Hypoxia-stimulated 18 F–FDG uptake was completely abrogated by silencing of HIF1α expression or by a specific inhibitor. There was a rapid and marked increase of reactive oxygen species (ROS) by hypoxia, and ROS scavenging or NADPH oxidase inhibition completely abolished hypoxia-stimulated HIF1α and 18 F–FDG accumulation, placing ROS production upstream of HIF1α signaling. Hypoxia-stimulated HIF1α and 18 F–FDG accumulation was blocked by the protein kinase C (PKC) inhibitor, staurosporine. The phosphatidylinositol 3-kinase (PI3K) inhibitor, wortmannin, blocked hypoxia-stimulated 18 F–FDG uptake and attenuated hypoxia-responsive element binding of HIF1α without influencing its accumulation. Thus, ROS-driven HIF1α accumulation, along with PKC and PI3K signaling, play a key role in triggering accelerated glycolysis in endothelial cells under hypoxia, thereby contributing to 18 F–FDG transport.

  5. Bladder urine oxygen tension for assessing renal medullary oxygenation in rabbits: experimental and modeling studies

    Science.gov (United States)

    Sgouralis, Ioannis; Kett, Michelle M.; Ow, Connie P. C.; Abdelkader, Amany; Layton, Anita T.; Gardiner, Bruce S.; Smith, David W.; Lankadeva, Yugeesh R.

    2016-01-01

    Oxygen tension (Po2) of urine in the bladder could be used to monitor risk of acute kidney injury if it varies with medullary Po2. Therefore, we examined this relationship and characterized oxygen diffusion across walls of the ureter and bladder in anesthetized rabbits. A computational model was then developed to predict medullary Po2 from bladder urine Po2. Both intravenous infusion of [Phe2,Ile3,Orn8]-vasopressin and infusion of NG-nitro-l-arginine reduced urinary Po2 and medullary Po2 (8–17%), yet had opposite effects on renal blood flow and urine flow. Changes in bladder urine Po2 during these stimuli correlated strongly with changes in medullary Po2 (within-rabbit r2 = 0.87–0.90). Differences in the Po2 of saline infused into the ureter close to the kidney could be detected in the bladder, although this was diminished at lesser ureteric flow. Diffusion of oxygen across the wall of the bladder was very slow, so it was not considered in the computational model. The model predicts Po2 in the pelvic ureter (presumed to reflect medullary Po2) from known values of bladder urine Po2, urine flow, and arterial Po2. Simulations suggest that, across a physiological range of urine flow in anesthetized rabbits (0.1–0.5 ml/min for a single kidney), a change in bladder urine Po2 explains 10–50% of the change in pelvic urine/medullary Po2. Thus, it is possible to infer changes in medullary Po2 from changes in urinary Po2, so urinary Po2 may have utility as a real-time biomarker of risk of acute kidney injury. PMID:27385734

  6. Postnatal follow-up of the oxygenation index, arterial to alveolar oxygen tension ratio and alveolar arterial oxygen tension difference values in neonates with the respiratory distress syndrome treated with conventional ventilatory support.

    Science.gov (United States)

    Atanasov, A; Despotova-Toleva, L

    1997-01-01

    Recent development of sophisticated intensive care technique for use in newborn infants with the respiratory distress syndrome (RDS) has resulted in changes in the therapeutic strategies and moved the problem of neonatal survival into the realm of new therapeutic realities. At present, the mechanical ventilation methods form an integral part of the intensive care strategy of infants with RDS. They have come to the forefront of infant care because of their successful use in ventilatory support and children survival where other therapeutic modalities have failed. The present prospective observational longitudinal study was designed to assess the real-time convenience, reliability and accuracy of the changes in the oxygenation index (OI), arterial-to-alveolar oxygen tension ratio (a/A PO2) and alveolar-arterial oxygen gradient (A-a)DO2 in ventilator-dependent neonates with RDS, to analyze their feasibility and potential information yield in oxygen inhalation therapy as well as their prognostic implications and predictive value. Twenty neonates with RDS, heralded by respiratory failure which necessitated the initiation of oxygen inhalation therapy and ventilatory support within 24 hours of birth, were enrolled in the study. Ten of the infants survived and the remaining ten died. OI, (a/A PO2) and (A-a)DO2 were followed up sequentially and thoroughly analyzed as the primary outcome measures of the study. The indices were calculated on the basis of the complete monitoring of the ventilatory equipment parameters and acid-base status carried out on an hourly basis. Our results show that: 1. The combination of three indexes (OI, (a/A)PO2 and (A-a)DO2 we propose is a useful discriminating predictor of neonatal lung maturity reflecting arterial blood gas status in ventilator-dependent neonates with RDS. 2. The indices detect the efficacy of the modern conventional ventilatory support with real-time convenience and reliable accuracy forming the cornerstone of clinical decision

  7. Study on the makinq of Cockroft Walton high tension

    International Nuclear Information System (INIS)

    Hutapea, Sumihar.

    1976-01-01

    A prototype of a generator is being developed at the GAMA Research Center. Experience in working with some components, high voltage capacitor, column, and potential divider is discussed. High voltage diode, the type which is usually used in television, is used. The tension of the generator is measured by using the high ohmic resistence of 4000 megaohm. The maximum tension can be reached no more than 150000 volts. (author)

  8. Towards a quantitative understanding of oxygen tension and cell density evolution in fibrin hydrogels.

    Science.gov (United States)

    Demol, Jan; Lambrechts, Dennis; Geris, Liesbet; Schrooten, Jan; Van Oosterwyck, Hans

    2011-01-01

    The in vitro culture of hydrogel-based constructs above a critical size is accompanied by problems of unequal cell distribution when diffusion is the primary mode of oxygen transfer. In this study, an experimentally-informed mathematical model was developed to relate cell proliferation and death inside fibrin hydrogels to the local oxygen tension in a quantitative manner. The predictive capacity of the resulting model was tested by comparing its outcomes to the density, distribution and viability of human periosteum derived cells (hPDCs) that were cultured inside fibrin hydrogels in vitro. The model was able to reproduce important experimental findings, such as the formation of a multilayered cell sheet at the hydrogel periphery and the occurrence of a cell density gradient throughout the hydrogel. In addition, the model demonstrated that cell culture in fibrin hydrogels can lead to complete anoxia in the centre of the hydrogel for realistic values of oxygen diffusion and consumption. A sensitivity analysis also identified these two parameters, together with the proliferation parameters of the encapsulated cells, as the governing parameters for the occurrence of anoxia. In conclusion, this study indicates that mathematical models can help to better understand oxygen transport limitations and its influence on cell behaviour during the in vitro culture of cell-seeded hydrogels. Copyright © 2010 Elsevier Ltd. All rights reserved.

  9. Exogenous and endogenous angiotensin‐II decrease renal cortical oxygen tension in conscious rats by limiting renal blood flow

    Science.gov (United States)

    Emans, Tonja W.; Janssen, Ben J.; Pinkham, Maximilian I.; Ow, Connie P. C.; Evans, Roger G.; Joles, Jaap A.; Malpas, Simon C.; Krediet, C. T. Paul

    2016-01-01

    Key points Our understanding of the mechanisms underlying the role of hypoxia in the initiation and progression of renal disease remains rudimentary.We have developed a method that allows wireless measurement of renal tissue oxygen tension in unrestrained rats.This method provides stable and continuous measurements of cortical tissue oxygen tension (PO2) for more than 2 weeks and can reproducibly detect acute changes in cortical oxygenation.Exogenous angiotensin‐II reduced renal cortical tissue PO2 more than equi‐pressor doses of phenylephrine, probably because it reduced renal oxygen delivery more than did phenylephrine.Activation of the endogenous renin–angiotensin system in transgenic Cyp1a1Ren2 rats reduced cortical tissue PO2; in this model renal hypoxia precedes the development of structural pathology and can be reversed acutely by an angiotensin‐II receptor type 1 antagonist.Angiotensin‐II promotes renal hypoxia, which may in turn contribute to its pathological effects during development of chronic kidney disease. Abstract We hypothesised that both exogenous and endogenous angiotensin‐II (AngII) can decrease the partial pressure of oxygen (PO2) in the renal cortex of unrestrained rats, which might in turn contribute to the progression of chronic kidney disease. Rats were instrumented with telemeters equipped with a carbon paste electrode for continuous measurement of renal cortical tissue PO2. The method reproducibly detected acute changes in cortical oxygenation induced by systemic hyperoxia and hypoxia. In conscious rats, renal cortical PO2 was dose‐dependently reduced by intravenous AngII. Reductions in PO2 were significantly greater than those induced by equi‐pressor doses of phenylephrine. In anaesthetised rats, renal oxygen consumption was not affected, and filtration fraction was increased only in the AngII infused animals. Oxygen delivery decreased by 50% after infusion of AngII and renal blood flow (RBF) fell by 3.3 ml min−1

  10. Oxygen, nitric oxide and articular cartilage

    Directory of Open Access Journals (Sweden)

    B Fermor

    2007-04-01

    Full Text Available Molecular oxygen is required for the production of nitric oxide (NO, a pro-inflammatory mediator that is associated with osteoarthritis and rheumatoid arthritis. To date there has been little consideration of the role of oxygen tension in the regulation of nitric oxide production associated with arthritis. Oxygen tension may be particularly relevant to articular cartilage since it is avascular and therefore exists at a reduced oxygen tension. The superficial zone exists at approximately 6% O2, while the deep zone exists at less than 1% O2. Furthermore, oxygen tension can alter matrix synthesis, and the material properties of articular cartilage in vitro.The increase in nitric oxide associated with arthritis can be caused by pro-inflammatory cytokines and mechanical stress. Oxygen tension significantly alters endogenous NO production in articular cartilage, as well as the stimulation of NO in response to both mechanical loading and pro-inflammatory cytokines. Mechanical loading and pro-inflammatory cytokines also increase the production of prostaglandin E2 (PGE2. There is a complex interaction between NO and PGE2, and oxygen tension can alter this interaction. These findings suggest that the relatively low levels of oxygen within the joint may have significant influences on the metabolic activity, and inflammatory response of cartilage as compared to ambient levels. A better understanding of the role of oxygen in the production of inflammatory mediators in response to mechanical loading, or pro-inflammatory cytokines, may aid in the development of strategies for therapeutic intervention in arthritis.

  11. Modelling of L-valine Repeated Fed-batch Fermentation Process Taking into Account the Dissolved Oxygen Tension

    Directory of Open Access Journals (Sweden)

    Tzanko Georgiev

    2009-03-01

    Full Text Available This article deals with synthesis of dynamic unstructured model of variable volume fed-batch fermentation process with intensive droppings for L-valine production. The presented approach of the investigation includes the following main procedures: description of the process by generalized stoichiometric equations; preliminary data processing and calculation of specific rates for main kinetic variables; identification of the specific rates takes into account the dissolved oxygen tension; establishment and optimisation of dynamic model of the process; simulation researches. MATLAB is used as a research environment.

  12. Optic nerve oxygenation

    DEFF Research Database (Denmark)

    Stefánsson, Einar; Pedersen, Daniella Bach; Jensen, Peter Koch

    2005-01-01

    The oxygen tension of the optic nerve is regulated by the intraocular pressure and systemic blood pressure, the resistance in the blood vessels and oxygen consumption of the tissue. The oxygen tension is autoregulated and moderate changes in intraocular pressure or blood pressure do not affect...... the optic nerve oxygen tension. If the intraocular pressure is increased above 40 mmHg or the ocular perfusion pressure decreased below 50 mmHg the autoregulation is overwhelmed and the optic nerve becomes hypoxic. A disturbance in oxidative metabolism in the cytochromes of the optic nerve can be seen...... at similar levels of perfusion pressure. The levels of perfusion pressure that lead to optic nerve hypoxia in the laboratory correspond remarkably well to the levels that increase the risk of glaucomatous optic nerve atrophy in human glaucoma patients. The risk for progressive optic nerve atrophy in human...

  13. Exogenous and endogenous angiotensin-II decrease renal cortical oxygen tension in conscious rats by limiting renal blood flow.

    Science.gov (United States)

    Emans, Tonja W; Janssen, Ben J; Pinkham, Maximilian I; Ow, Connie P C; Evans, Roger G; Joles, Jaap A; Malpas, Simon C; Krediet, C T Paul; Koeners, Maarten P

    2016-11-01

    Our understanding of the mechanisms underlying the role of hypoxia in the initiation and progression of renal disease remains rudimentary. We have developed a method that allows wireless measurement of renal tissue oxygen tension in unrestrained rats. This method provides stable and continuous measurements of cortical tissue oxygen tension (PO2) for more than 2 weeks and can reproducibly detect acute changes in cortical oxygenation. Exogenous angiotensin-II reduced renal cortical tissue PO2 more than equi-pressor doses of phenylephrine, probably because it reduced renal oxygen delivery more than did phenylephrine. Activation of the endogenous renin-angiotensin system in transgenic Cyp1a1Ren2 rats reduced cortical tissue PO2; in this model renal hypoxia precedes the development of structural pathology and can be reversed acutely by an angiotensin-II receptor type 1 antagonist. Angiotensin-II promotes renal hypoxia, which may in turn contribute to its pathological effects during development of chronic kidney disease. We hypothesised that both exogenous and endogenous angiotensin-II (AngII) can decrease the partial pressure of oxygen (PO2) in the renal cortex of unrestrained rats, which might in turn contribute to the progression of chronic kidney disease. Rats were instrumented with telemeters equipped with a carbon paste electrode for continuous measurement of renal cortical tissue PO2. The method reproducibly detected acute changes in cortical oxygenation induced by systemic hyperoxia and hypoxia. In conscious rats, renal cortical PO2 was dose-dependently reduced by intravenous AngII. Reductions in PO2 were significantly greater than those induced by equi-pressor doses of phenylephrine. In anaesthetised rats, renal oxygen consumption was not affected, and filtration fraction was increased only in the AngII infused animals. Oxygen delivery decreased by 50% after infusion of AngII and renal blood flow (RBF) fell by 3.3 ml min -1 . Equi-pressor infusion of

  14. Oxygen tension and riboflavin gradients cooperatively regulate the migration of Shewanella oneidensis MR-1 revealed by a hydrogel-based microfluidic device

    Directory of Open Access Journals (Sweden)

    Beum Jun Kim

    2016-09-01

    Full Text Available Shewanella oneidensis (S. oneidensis is a model bacterial strain for studies of bioelectrochemical systems (BESs. It has two extracellular electron transfer pathways: 1 shuttling electrons via an excreted mediator riboflavin; and 2 direct contact between the c-type cytochromes at the cell membrane and the electrode. Despite the extensive use of S. oneidensis in bioelectrochemical systems such as microbial fuel cells and biosensors, many basic microbiology questions about S. oneidensis in the context of BES remain unanswered. Here, we present studies of motility and chemotaxis of S. oneidensis under well controlled concentration gradients of two electron acceptors, oxygen and oxidized form of riboflavin (flavin+ using a newly developed microfluidic platform. Experimental results demonstrate that either oxygen or flavin+ is a chemoattractant to S. oneidensis. The chemotactic tendency of S. oneidensis in a flavin+ concentration gradient is significantly enhanced in an anaerobic in contrast to an aerobic condition. Furthermore, either a low oxygen tension or a high flavin+ concentration considerably enhances the speed of S. oneidensis. This work presents a robust microfluidic platform for generating oxygen and/or flavin+ gradients in an aqueous environment, and demonstrates that two important electron acceptors, oxygen and oxidized riboflavin, cooperatively regulate S. oneidensis migration patterns. The microfluidic tools presented as well as the knowledge gained in this work can be used to guide the future design of BESs for efficient electron production.

  15. Improving corrosion resistance of post-tensioned substructures emphasizing high performance grouts

    Science.gov (United States)

    Schokker, Andrea Jeanne

    The use of post-tensioning in bridges can provide durability and structural benefits to the system while expediting the construction process. When post-tensioning is combined with precast elements, traffic interference can be greatly reduced through rapid construction. Post-tensioned concrete substructure elements such as bridge piers, hammerhead bents, and straddle bents have become more prevalent in recent years. Chloride induced corrosion of steel in concrete is one of the most costly forms of corrosion each year. Coastal substructure elements are exposed to seawater by immersion or spray, and inland bridges may also be at risk due to the application of deicing salts. Corrosion protection of the post-tensioning system is vital to the integrity of the structure because loss of post-tensioning can result in catastrophic failure. Documentation for durability design of the grout, ducts, and anchorage systems is very limited. The objective of this research is to evaluate the effectiveness of corrosion protection measures for post-tensioned concrete substructures by designing and testing specimens representative of typical substructure elements using state-of-the-art practices in aggressive chloride exposure environments. This was accomplished through exposure testing of twenty-seven large-scale beam specimens and ten large-scale column specimens. High performance grout for post-tensioning tendon injection was also developed through a series of fresh property tests, accelerated exposure tests, and a large-scale pumping test to simulate field conditions. A high performance fly ash grout was developed for applications with small vertical rises, and a high performance anti-bleed grout was developed for applications involving large vertical rises such as tall bridge piers. Long-term exposure testing of the beam and column specimens is ongoing, but preliminary findings indicate increased corrosion protection with increasing levels of post-tensioning, although traditional

  16. Development of bovine embryos cultured in CR1aa and IVD101 media using different oxygen tensions and culture systems.

    Science.gov (United States)

    Somfai, Tamás; Inaba, Yasushi; Aikawa, Yoshio; Ohtake, Masaki; Kobayashi, Shuji; Konishi, Kazuyuki; Nagai, Takashi; Imai, Kei

    2010-12-01

    The aim of the present study was to optimise the culture conditions for the in vitro production of bovine embryos. The development of in vitro fertilised bovine oocytes in CR1aa supplemented with 5% calf serum and IVD101 culture media were compared using traditional microdrops and Well of the Well (WOW) culture systems either under 5% or 20% oxygen tension. After 7 days of culture, a significantly higher blastocyst formation rate was obtained for embryos cultured in CR1aa medium compared to those cultured in IVD101, irrespective of O2 tensions and culture systems. The blastocyst formation in IVD101 was suppressed under 20% O2 compared to 5% O2 . Despite their similar total cell numbers, higher rates of inner cell mass (ICM) cells were observed in blastocysts developed in IVD101 medium than in those developed in CR1aa, irrespective of O2 tensions. There was no significant difference in blastocyst formation, total, ICM and trophectoderm (TE) cell numbers between embryos obtained by microdrop and WOW culture systems irrespective of the culture media and O2 tensions used. In conclusion, CR1aa resulted in higher blastocyst formation rates irrespective of O2 tension, whereas IVD101 supported blastocyst formation only under low O2 levels but enhanced the proliferation of ICM cells.

  17. Diet-induced weight loss decreases adipose tissue oxygen tension with parallel changes in adipose tissue phenotype and insulin sensitivity in overweight humans

    NARCIS (Netherlands)

    Vink, R.G.; Roumans, N.J.; Čajlaković, M.; Cleutjens, J.P.M.; Boekschoten, M.V.; Fazelzadeh, P.; Vogel, M.A.A.; Blaak, E.E.; Mariman, E.C.; Baak, van M.A.; Goossens, G.H.

    2017-01-01

    Background/objectives: Although adipose tissue (AT) hypoxia is present in rodent models of obesity, evidence for this in humans is limited. Here, we investigated the effects of diet-induced weight loss (WL) on abdominal subcutaneous AT oxygen tension (pO 2), AT blood flow (ATBF), AT capillary

  18. Comparison of Preterm and Term Wharton's Jelly-Derived Mesenchymal Stem Cell Properties in Different Oxygen Tensions.

    Science.gov (United States)

    Balgi-Agarwal, Saloni; Winter, Caitlyn; Corral, Alexis; Mustafa, Shamimunisa B; Hornsby, Peter; Moreira, Alvaro

    2018-06-27

    Mesenchymal stem cells (MSCs) have shown promise as therapeutic agents in treating morbidities associated with premature birth. MSCs derived from the human umbilical cord are easy to isolate and have low immunogenicity and a robust ability to secrete paracrine factors. To date, there are no studies evaluating preterm versus term umbilical cord tissue-derived MSCs. Therefore, our aim was twofold: (1) to compare stem cell properties in preterm versus term MSCs and (2) to examine the impact of oxygen tension on stem cell behavior. Umbilical cord tissue was obtained from 5 preterm and 5 term neonates. The cells were isolated and characterized as MSCs in accordance with the International Society for Cellular Therapy. We exposed MSCs to different oxygen tensions to examine the impact of environmental factors on cell performance. We studied the following stem cell properties: (i) motility, (ii) proliferation, (iii) senescence, (iv) cell viability, (v) colony-forming unit efficiency, and (vi) inflammatory cytokine expression. Under normoxia (21% O2), cells from preterm and term infants had similar properties. Under hypoxic conditions (1% O2), term MSCs had better cell proliferation; however, cells exposed to hyperoxia (90% O2) had the slowest motility and lowest cell viability (p cytokine expression between the groups. The term cells demonstrated more colony-forming efficiency than the preterm cells. In sum, our preliminary findings suggest that MSCs derived from term and preterm umbilical cords have similar characteristics, offering the potential of future autologous/allogeneic MSC transplants in neonates. © 2018 S. Karger AG, Basel.

  19. Closed Loop Control of Oxygen Delivery and Oxygen Generation

    Science.gov (United States)

    2017-08-01

    were used for this study and were connected via a USB cable to allow communication. The ventilator was modified to allow closed loop control of oxygen...connected via a USB cable to allow communication. The ventilator was modified to allow closed loop control of oxygen based on the oxygen saturation...2017-4119, 28 Aug 2017. oximetry (SpO2) and intermittent arterial blood sampling for arterial oxygen tension (partial pressure of oxygen [PaO2]) and

  20. Localized increase of tissue oxygen tension by magnetic targeted drug delivery

    Science.gov (United States)

    Liong, Celine; Ortiz, Daniel; Ao-ieong, Eilleen; Navati, Mahantesh S.; Friedman, Joel M.; Cabrales, Pedro

    2014-07-01

    Hypoxia is the major hindrance to successful radiation therapy of tumors. Attempts to increase the oxygen (O2) tension (PO2) of tissue by delivering more O2 have been clinically disappointing, largely due to the way O2 is transported and released by the hemoglobin (Hb) within the red blood cells (RBCs). Systemic manipulation of O2 transport increases vascular resistance due to metabolic autoregulation of blood flow to prevent over oxygenation. This study investigates a new technology to increase O2 delivery to a target tissue by decreasing the Hb-O2 affinity of the blood circulating within the targeted tissue. As the Hb-O2 affinity decreases, the tissue PO2 to satisfy tissue O2 metabolic needs increases without increasing O2 delivery or extraction. Paramagnetic nanoparticles (PMNPs), synthetized using gadolinium oxide, were coated with the cell permeable Hb allosteric effector L35 (3,5-trichlorophenylureido-phenoxy-methylpropionic acid). L35 decreases Hb affinity for O2 and favors the release of O2. The L35-coated PMNPs (L35-PMNPs) were intravenously infused (10 mg kg-1) to hamsters instrumented with the dorsal window chamber model. A magnetic field of 3 mT was applied to localize the effects of the L35-PMNPs to the window chamber. Systemic O2 transport characteristics and microvascular tissue oxygenation were measured after administration of L35-PMNPs with and without magnetic field. The tissue PO2 in untreated control animals was 25.2 mmHg. L35-PMNPs without magnetic field decreased tissue PO2 to 23.4 mmHg, increased blood pressure, and reduced blood flow, largely due to systemic modification of Hb-O2 affinity. L35-PMNPs with magnetic field increased tissue PO2 to 27.9 mmHg, without systemic or microhemodynamic changes. These results indicate that localized modification of Hb-O2 affinity can increase PO2 of target tissue without affecting systemic O2 delivery or triggering O2 autoregulation mechanisms. This technology can be used to treat local hypoxia and to

  1. Electrical injuries due to railway high tension cables.

    Science.gov (United States)

    Reichl, M; Kay, S

    1985-08-01

    We have noted a large number of young boys being admitted to our Unit with burns due to railway high tension cables. On review of these cases we have noted: most of the burns were due to arcing, there is a high level of ignorance among the population at risk. We propose some ways of preventing these injuries.

  2. IVF/ICSI outcomes after culture of human embryos at low oxygen tension: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Gomes Sobrinho David B

    2011-11-01

    Full Text Available Abstract Background Improved pregnancy, implantation, and birth rates have been reported after the use of reduced O2 concentration during embryo culture, mainly due to a reduction of the cumulative detrimental effects of reactive oxygen species. However, some studies have failed to report any positive effects. The objective of this meta-analysis was to evaluate the effect of a low-O2 environment on IVF/intracytoplasmic sperm injection (ICSI outcomes. Methods All available published and ongoing randomised trials that compared the effects of low (~5%; OC~5 and atmospheric (~20%; OC~20 oxygen concentrations on IVF/ICSI outcomes were included. Search strategies included online surveys of databases from 1980 to 2011. The outcomes measured were fertilisation rate, implantation rate and ongoing pregnancy rates. The fixed effects model was used to calculate the odds ratio. Results Seven studies were included in this analysis. The pooled fertilisation rate did not differ significantly (P = 0.54 between the group of oocytes cultured at low O2 tension and the group at atmospheric O2 tension. Concerning all cycles, the implantation (P = 0.06 and ongoing pregnancy (P = 0.051 rates were not significantly different between the group receiving transferred sets containing only OC~5 embryos and the group receiving transferred sets with only OC~20 embryos. In a meta-analysis performed for only those trials in which embryos were transferred on day 2/3, implantation (P = 0.63 and ongoing pregnancy (P = 0.19 rates were not significantly different between the groups. In contrast, when a meta-analysis was performed using only trials in which embryos were transferred on days 5 and 6 (at the blastocyst stage, the group with transferred sets of only OC~5 embryos showed a statistically significantly higher implantation rate (P = 0.006 than the group receiving transferred sets with only OC~20 embryos, although the ongoing pregnancy (P = 0.19 rates were not significantly

  3. Oxygen tension regulates the miRNA profile and bioactivity of exosomes released from extravillous trophoblast cells - Liquid biopsies for monitoring complications of pregnancy.

    Directory of Open Access Journals (Sweden)

    Grace Truong

    Full Text Available Our understanding of how cells communicate has undergone a paradigm shift since the recent recognition of the role of exosomes in intercellular signaling. In this study, we investigated whether oxygen tension alters the exosome release and miRNA profile from extravillous trophoblast (EVT cells, modifying their bioactivity on endothelial cells (EC. Furthermore, we have established the exosomal miRNA profile at early gestation in women who develop pre-eclampsia (PE and spontaneous preterm birth (SPTB. HTR-8/SVneo cells were used as an EVT model. The effect of oxygen tension (i.e. 8% and 1% oxygen on exosome release was quantified using nanocrystals (Qdot® coupled to CD63 by fluorescence NTA. A real-time, live-cell imaging system (Incucyte™ was used to establish the effect of exosomes on EC. Plasma samples were obtained at early gestation (<18 weeks and classified according to pregnancy outcomes. An Illumina TrueSeq Small RNA kit was used to construct a small RNA library from exosomal RNA obtained from EVT and plasma samples. The number of exosomes was significantly higher in EVT cultured under 1% compared to 8% oxygen. In total, 741 miRNA were identified in exosomes from EVT. Bioinformatic analysis revealed that these miRNA were associated with cell migration and cytokine production. Interestingly, exosomes isolated from EVT cultured at 8% oxygen increased EC migration, whilst exosomes cultured at 1% oxygen decreased EC migration. These changes were inversely proportional to TNF-α released from EC. Finally, we have identified a set of unique miRNAs in exosomes from EVT cultured at 1% oxygen and exosomes isolated from the circulation of mothers at early gestation, who later developed PE and SPTB. We suggest that aberrant exosomal signalling by placental cells is a common aetiological factor in pregnancy complications characterised by incomplete SpA remodeling and is therefore a clinically relevant biomarker of pregnancy complications.

  4. Oxygen dependency of porfiromycin cytotoxicity

    International Nuclear Information System (INIS)

    Marshall, R.S.; Rauth, A.M.

    1987-01-01

    The authors determined the oxygen dependency of toxicity for the bioreductive alkylating agents mitomycin C (MMC) and porfiromycin (PM) to investigate whether the toxicities of these agents increase in the range of oxygen tensions over which cells become increasingly radioresistant. In the present work the oxygen dependency of PM in CHO cells was determined by assaying survival as a function of time of exposure to 1.0 μg/ml PM under various known levels of oxygen. While PM demonstrated preferential hypoxic cell toxicity, aerobic cell survival was reduced ten-fold after five hours of exposure. Conversely, PM toxicity after a five hour hypoxic exposure to <0.001% oxygen appeared to be greater than that observed for similar MMC exposures, suggesting that PM may be more selective than MMC in killing hypoxic rather than aerobic cells. The authors are currently investigating this preferential toxicity in two human cell lines, one of which is resistant to these agents. At present, these observations suggest that PM may be more effective than MMC at destroying tumour cells in regions of intermediate and low oxygen tensions which may survive radiotherapy, though the range of oxygen tensions which mediate toxicity is similar for both agents

  5. Radiosensitizers and the oxygen effects in mammalian cells

    International Nuclear Information System (INIS)

    Millar, B.C.; Fielden, E.M.; Steele, J.J.

    1979-01-01

    The survival curves for Chinese Hamster cells irradiated under various oxygen tensions have been determined. The variation in OER with oxygen concentration shows two distinct components. Between 1.4 and 7.0 μM the OER is constant with a value of 1.9. Experiments with nitroaromatic radiosensitizers in combination with low concentrations of oxygen show that they can all mimic the 'low concentration' oxygen effect. Of the compounds tested only misonidazole can apparently mimic the 'high concentration' oxygen effect although the full OER cannot be obtained with the authors cell line because of toxicity by the sensitizer. (Auth.)

  6. Near-simultaneous hemoglobin saturation and oxygen tension maps in mouse brain using an AOTF microscope.

    Science.gov (United States)

    Shonat, R D; Wachman, E S; Niu, W; Koretsky, A P; Farkas, D L

    1997-09-01

    A newly developed microscope using acousto-optic tunable filters (AOTFs) was used to generate in vivo hemoglobin saturation (SO2) and oxygen tension (PO2) maps in the cerebral cortex of mice. SO2 maps were generated from the spectral analysis of reflected absorbance images collected at different wavelengths, and PO2 maps were generated from the phosphorescence lifetimes of an injected palladium-porphyrin compound using a frequency-domain measurement. As the inspiratory O2 was stepped from hypoxia (10% O2), through normoxia (21% O2), to hyperoxia (60% O2), measured SO2 and PO2 levels rose accordingly and predictably throughout. A plot of SO2 versus PO2 in different arterial and venous regions of the pial vessels conformed to the sigmoidal shape of the oxygen-hemoglobin dissociation curve, providing further validation of the two mapping procedures. The study demonstrates the versatility of the AOTF microscope for in vivo physiologic investigation, allowing for the generation of nearly simultaneous SO2 and PO2 maps in the cerebral cortex, and the frequency-domain detection of phosphorescence lifetimes. This class of study opens up exciting new possibilities for investigating the dynamics of hemoglobin and O2 binding during functional activation of neuronal tissues.

  7. Oxygen tension measurements of tumors growing in mice

    International Nuclear Information System (INIS)

    Adam, Markus F.; Dorie, Mary Jo; Brown, J. Martin

    1999-01-01

    Purpose: Clinical studies using the Eppendorf histograph have shown that patients whose tumors have a low pO 2 have worse local control after radiotherapy, and have higher metastatic rates. Because preclinical studies of methods of overcoming, or exploiting, hypoxia generally use transplanted tumors in mice, we have compared the oxygenation of mouse tumors with human tumors to determine the appropriateness of the transplanted mouse model for such preclinical studies. Methods and Materials: We evaluated the oxygenation status of subcutaneous (s.c.) tissue and of 12 intradermally (i.d.)- and 7 s.c.-growing mouse or human transplanted tumors in mice using the Eppendorf histograph, and compared the values obtained with measurements of human head and neck nodes. Results: The normal tissue pO 2 profile of air-breathing mice showed a nearly Gaussian distribution (38.2 ± 14.9 mmHg). Breathing 10% O 2 or carbogen resulted in dramatic changes in normal tissue oxygenation. Tumors growing intradermally in the back of air-breathing mice were extremely hypoxic and resistant to expected changes in oxygenation (carbogen breathing, size, and use of anesthetics). Tumors growing s.c. in the foot showed higher oxygen profiles with marked changes in oxygenation when exposing the animals to different levels of oxygen. However, the oxygenation of the mouse tumors transplanted in either site was only a fraction of that of the majority of human tumors. Conclusion: Experimental mouse tumors are markedly hypoxic, with median values of 10-20% of those of human tumors. Hence, mouse tumors are probably good models for the most hypoxic human tumors that respond poorly to radiotherapy; however, caution has to be exercised in extrapolating data from mouse to man

  8. The effect of oxygen tension on porcine embryonic development is dependent on embryo type

    DEFF Research Database (Denmark)

    Booth, Paul; Holm, Peter; Callesen, Henrik

    2005-01-01

    of the embryos prior to culture--a study was performed to examine the effect of O2 tension during culture on three different types of porcine embryos, namely: in vivo flushed embryos, and in vitro matured oocytes either fertilized in vitro or parthenogenetically activated. In vivo embryos (n=208) were flushed...... supplemented with 10% calf serum until day 7. The gas environment for IVM/IVF was 5% CO2 in air, while that for IVC was either 5% CO2 in air or 5% O2, 5% CO2 and 90% N2. Low O2 tension increased both day 7 blastocyst rates (high versus low O2, respectively; 9.3+/-2.9%: 26/280; 23.9+/-4.2%: 71/293; P...

  9. Membrane culture and reduced oxygen tension enhances cartilage matrix formation from equine cord blood mesenchymal stromal cells in vitro.

    Science.gov (United States)

    Co, C; Vickaryous, M K; Koch, T G

    2014-03-01

    Ongoing research is aimed at increasing cartilage tissue yield and quality from multipotent mesenchymal stromal cells (MSC) for the purpose of treating cartilage damage in horses. Low oxygen culture has been shown to enhance chondrogenesis, and novel membrane culture has been proposed to increase tissue yield and homogeneity. The objective of this study was to evaluate and compare the effect of reduced oxygen and membrane culture during in vitro chondrogenesis of equine cord blood (CB) MSC. CB-MSC (n = 5 foals) were expanded at 21% oxygen prior to 3-week differentiation in membrane or pellet culture at 5% and 21% oxygen. Assessment included histological examination (H&E, toluidine Blue, immunohistochemistry (IHC) for collagen type I and II), protein quantification by hydroxyproline assay and dimethylmethylene assay, and mRNA analysis for collagen IA1, collagen IIA1, collagen XA1, HIF1α and Sox9. Among treatment groups, 5% membrane culture produced neocartilage most closely resembling hyaline cartilage. Membrane culture resulted in increased wet mass, homogenous matrix morphology and an increase in total collagen content, while 5% oxygen culture resulted in higher GAG and type II collagen content. No significant differences were observed for mRNA analysis. Membrane culture at 5% oxygen produces a comparatively larger amount of higher quality neocartilage. Matrix homogeneity is attributed to a uniform diffusion gradient and reduced surface tension. Membrane culture holds promise for scale-up for therapeutic purposes, for cellular preconditioning prior to cytotherapeutic applications, and for modeling system for gas-dependent chondrogenic differentiation studies. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  10. Mixomics analysis of Bacillus subtilis: effect of oxygen availability on riboflavin production.

    Science.gov (United States)

    Hu, Junlang; Lei, Pan; Mohsin, Ali; Liu, Xiaoyun; Huang, Mingzhi; Li, Liang; Hu, Jianhua; Hang, Haifeng; Zhuang, Yingping; Guo, Meijin

    2017-09-12

    Riboflavin, an intermediate of primary metabolism, is one kind of important food additive with high economic value. The microbial cell factory Bacillus subtilis has already been proven to possess significant importance for the food industry and have become one of the most widely used riboflavin-producing strains. In the practical fermentation processes, a sharp decrease in riboflavin production is encountered along with a decrease in the dissolved oxygen (DO) tension. Influence of this oxygen availability on riboflavin biosynthesis through carbon central metabolic pathways in B. subtilis is unknown so far. Therefore the unveiled effective metabolic pathways were still an unaccomplished task till present research work. In this paper, the microscopic regulation mechanisms of B. subtilis grown under different dissolved oxygen tensions were studied by integrating 13 C metabolic flux analysis, metabolomics and transcriptomics. It was revealed that the glucose metabolic flux through pentose phosphate (PP) pathway was lower as being confirmed by smaller pool sizes of metabolites in PP pathway and lower expression amount of ykgB at transcriptional level. The latter encodes 6-phosphogluconolactonase (6-PGL) under low DO tension. In response to low DO tension in broth, the glucose metabolic flux through Embden-Meyerhof-Parnas (EMP) pathway was higher and the gene, alsS, encoding for acetolactate synthase was significantly activated that may result due to lower ATP concentration and higher NADH/NAD + ratio. Moreover, ResE, a membrane-anchored protein that is capable of oxygen regulated phosphorylase activity, and ResD, a regulatory protein that can be phosphorylated and dephosphorylated by ResE, were considered as DO tension sensor and transcriptional regulator respectively. This study shows that integration of transcriptomics, 13 C metabolic flux analysis and metabolomics analysis provides a comprehensive understanding of biosynthesized riboflavin's regulatory mechanisms in

  11. Simulation of press-forming for automobile part using ultra high tension steel

    Directory of Open Access Journals (Sweden)

    Tanabe I.

    2012-08-01

    Full Text Available In recent years, ultra high tension steel has gradually been used in the automobile industry. The development of press-forming technology is now essential by reason of its high productivity and high product quality. In this study, tensile tests were performed with a view to understanding the material properties. Press-forming tests were then carried out with regard to the behaviors of spring back and deep-drawability, and manufacturing a real product. The ultra high tension steel used in the experiments had a thickness of 1 mm and a tensile strength of 1000 MPa. Finally, simulations of spring back, deep-drawability and manufacturing a real product in ultra high tension steel were conducted and evaluated in order to calculate the optimum-press-forming conditions and the optimum shape of the die. FEM with non-linear and dynamic analysis using Euler-Lagrange’s element was used for the simulations. It is concluded from the results that (1 the simulations conformed to the results of the experiments (2 the simulations proved very effective for calculating the optimum press conditions and die shape.

  12. Critical oxygen tension and the effect of hypoxia on the oxygen consumption of the striped catfish, Pangasius hypophthaimos (Pangasiidae)

    DEFF Research Database (Denmark)

    Lefevre, S.; Bayley, Mark; Wang, Tobias

    2008-01-01

    The striped catfish (Pangasius hypophthalmus) is an air-breathing teleost that uses a modified swim bladder for aerial gas exchange. Pangasius is of enormous importance for aquaculture industry in the Mekong Delta(Vietnam), but little is known about its physiology. We have initiated a series...... consumption (VO2), measured with intermittent closed respirometry, was 67.8 ± 5.1 mLO2/kg/h when the fish were maintained without access to air at 27 °C. The critical oxygen tension (Pcrit) at these conditions was 57.9 ± 8.9 mmHg (N = 7). The metabolic response to aquatic hypoxia was studied in fish subjected....... The ontogenetic effect of environmental PO2 on metabolism is currently under investigation with fish being reared in 30%, 60% and 100% saturation. Data on resting VO2and Pcrit will be presented and discussed for these animals....

  13. Influence of copper high-tension lines on plants and soils

    Energy Technology Data Exchange (ETDEWEB)

    Kraal, H.; Ernst, W.

    1976-09-01

    The copper contents of plants and soils were determined in relation to the distance from copper high-tension lines. In the vicinity of the cables clayey and fenny soils had demonstrably higher copper contents, due to corrosion of the cables, than regions 20 m and more outside the high-tension lines. On these soils, however, copper accumulation in the plants was low in comparison with those from a sandy soil, although this soil itself showed no copper increase in relation to the cables. The contaminated plants may present a risk of poisoning for sheep within a 20 m distance on both sides of the cables. No changes in plant species composition and in the copper tolerance of Agrostis tenuis were observed.

  14. Oxygen Modulates Human Decidual Natural Killer Cell Surface Receptor Expression and Interactions with Trophoblasts1

    Science.gov (United States)

    Wallace, Alison E.; Goulwara, Sonu S.; Whitley, Guy S.; Cartwright, Judith E.

    2014-01-01

    Decidual natural killer (dNK) cells have been shown to both promote and inhibit trophoblast behavior important for decidual remodeling in pregnancy and have a distinct phenotype compared to peripheral blood NK cells. We investigated whether different levels of oxygen tension, mimicking the physiological conditions of the decidua in early pregnancy, altered cell surface receptor expression and activity of dNK cells and their interactions with trophoblast. dNK cells were isolated from terminated first-trimester pregnancies and cultured in oxygen tensions of 3%, 10%, and 21% for 24 h. Cell surface receptor expression was examined by flow cytometry, and the effects of secreted factors in conditioned medium (CM) on the trophoblast cell line SGHPL-4 were assessed in vitro. SGHPL-4 cells treated with dNK cell CM incubated in oxygen tensions of 10% were significantly more invasive (P cells treated with dNK cell CM incubated in oxygen tensions of 3% or 21%. After 24 h, a lower percentage of dNK cells expressed CD56 at 21% oxygen (P cells expressed NKG2D at 10% oxygen (P oxygen tensions, with large patient variation. This study demonstrates dNK cell phenotype and secreted factors are modulated by oxygen tension, which induces changes in trophoblast invasion and endovascular-like differentiation. Alterations in dNK cell surface receptor expression and secreted factors at different oxygen tensions may represent regulation of function within the decidua during the first trimester of pregnancy. PMID:25232021

  15. High-Energy-Density Metal-Oxygen Batteries: Lithium-Oxygen Batteries vs Sodium-Oxygen Batteries.

    Science.gov (United States)

    Song, Kyeongse; Agyeman, Daniel Adjei; Park, Mihui; Yang, Junghoon; Kang, Yong-Mook

    2017-12-01

    The development of next-generation energy-storage devices with high power, high energy density, and safety is critical for the success of large-scale energy-storage systems (ESSs), such as electric vehicles. Rechargeable sodium-oxygen (Na-O 2 ) batteries offer a new and promising opportunity for low-cost, high-energy-density, and relatively efficient electrochemical systems. Although the specific energy density of the Na-O 2 battery is lower than that of the lithium-oxygen (Li-O 2 ) battery, the abundance and low cost of sodium resources offer major advantages for its practical application in the near future. However, little has so far been reported regarding the cell chemistry, to explain the rate-limiting parameters and the corresponding low round-trip efficiency and cycle degradation. Consequently, an elucidation of the reaction mechanism is needed for both lithium-oxygen and sodium-oxygen cells. An in-depth understanding of the differences and similarities between Li-O 2 and Na-O 2 battery systems, in terms of thermodynamics and a structural viewpoint, will be meaningful to promote the development of advanced metal-oxygen batteries. State-of-the-art battery design principles for high-energy-density lithium-oxygen and sodium-oxygen batteries are thus reviewed in depth here. Major drawbacks, reaction mechanisms, and recent strategies to improve performance are also summarized. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Effects of Low and High Oxygen Tensions and Related Respiratory Conditions on Visual Performance: A Literature Review

    Science.gov (United States)

    1988-07-01

    and of the same subject after a diet that made him deficient in Vitamin A. They used only one healthy well-trained observer. Measurementv of...background intensity. The authors do not discuss hypoxia changes in some other visual process, but this improvement above 15,000 feet may reflect hypo ...these studies, Gellhorn and Spiesman (1935) induced caloric nystagmus while subjects breathed mixtures high in CO2 and low in oxygen, and also after

  17. Simultaneous Monitoring of Vascular Oxygenation and Tissue Oxygen Tension of Breast Tumors Under Hyperbaric Oxygen Exposure

    Science.gov (United States)

    2008-04-01

    28. Alagoz, T., R. Buller, B. Anderson, K. Terrell , R...and oxygenation Ann . New Acad. Sci. 838 29–45 Chapman J D, Stobbe C C, Arnfield M R, Santus R, Lee J and McPhee M S 1991 Oxygen dependency of tumor

  18. Oxygenation measurement by multi-wavelength oxygen-dependent phosphorescence and delayed fluorescence: catchment depth and application in intact heart

    NARCIS (Netherlands)

    Balestra, Gianmarco M.; Aalders, Maurice C. G.; Specht, Patricia A. C.; Ince, Can; Mik, Egbert G.

    2015-01-01

    Oxygen delivery and metabolism represent key factors for organ function in health and disease. We describe the optical key characteristics of a technique to comprehensively measure oxygen tension (PO(2)) in myocardium, using oxygen-dependent quenching of phosphorescence and delayed fluorescence of

  19. Development of pulmonary vascular response to oxygen

    International Nuclear Information System (INIS)

    Morin, F.C. III; Egan, E.A.; Ferguson, W.; Lundgren, C.E.

    1988-01-01

    The ability of the pulmonary circulation of the fetal lamb to respond to a rise in oxygen tension was studied from 94 to 146 days of gestation. The unanesthetized ewe breathed room air at normal atmospheric pressure, followed by 100% oxygen at three atmospheres absolute pressure in a hyperbaric chamber. In eleven near-term lambs, fetal arterial oxygen tension (Pa O 2 ) increased from 25 to 55 Torr, which increased the proportion or right ventricular output distributed to the fetal lungs from 8 to 59%. In five very immature lambs fetal Pa O 2 increased from 27 to 174 Torr, but the proportion of right ventricular output distributed to the lung did not change. In five of the near-term lambs, pulmonary blood flow was measured. For each measurement of the distribution of blood flow, approximately 8 x 10 5 spheres of 15-μm diameter, labeled with either 153 Gd, 113 Sn, 103 Ru, 95 Nb, or 46 Sc were injected. It increased from 34 to 298 ml · kg fetal wt -1 · min -1 , an 8.8-fold increase. The authors conclude that the pulmonary circulation of the fetal lamb does not respond to an increase in oxygen tension before 101 days of gestation; however, near term an increase in oxygen tension alone can induce the entire increase in pulmonary blood flow that normally occurs after the onset of breathing at birth

  20. Measurement of brain oxygenation changes using dynamic T1-weighted imaging

    DEFF Research Database (Denmark)

    Haddock, Bryan; Larsson, Henrik B W; Hansen, Adam E

    2013-01-01

    Magnetic resonance imaging (MRI) has proven useful in evaluating oxygenation in several types of tissue and blood. This study evaluates brain tissue oxygenation changes between normoxia and hyperoxia in healthy subjects using dynamic T1 and T2*-weighted imaging sequences. The change in FiO2 induced...... by hyperoxia caused a significant decrease in T1. A model to determine changes in tissue oxygen tension from the T1-weighted MRI signal is presented based on previous findings that T1 is sensitive to oxygen tension whereas T2* is sensitive to blood saturation. The two sequences produce results with different...... regional and temporal dynamics. These differences combined with results from simulations of the T1 signal intensities, indicate an increase in extravascular oxygen tension during hyperoxia. This study concludes that T1 and T2* responses to FiO2 serve as independent biomarkers of oxygen physiology...

  1. Intervention of oxygen-control ability to radiation sensitivity, cell aging and cell transformation

    International Nuclear Information System (INIS)

    Yoshii, Hanako; Watanabe, Masami

    2009-01-01

    Oxygen is essential for life, and cells have therefore developed numerous adaptive responses to oxygen change. Here, we examined the difference in oxygen-control functions of human (HE), mouse (ME), and Syrian hamster embryo (SHE) cells cultured under different oxygen conditions (0.5%, 2% and 20%), and also examined whether oxygen tensions contributed to cellular lifespan and transformation. HE cells had their replicative lifespan slightly extended under hypoxic (0.5% and 2% oxygen) conditions, but were not immortalized under any of the oxygen concentrations. On the other hand, although ME cells cultured under 20% oxygen tension decreased their proliferation potency temporarily at early stage, all rodent cells were immortalized and acquired anchorage-independency, regardless of oxygen tension. These results suggest that cellular oxygen control function is related to sensitivities cellular immortalization and transformation. To understand intervention of oxygen control ability on cellular immortalization and transformation, we examined the intracellular oxidative level, mitochondria functions and radiation sensitivity. Intracellular oxidative levels of hypoxically cultured rodent cells were significantly enhanced. Mitochondrial membrane potential was altered depend on oxygen tensions, but the change was not parallel to mitochondria number in rodent cells. ME cells were particularly sensitive to oxygen change, and showed a clear oxygen effect on the X-ray survival. However, there was no difference in frequency of radiation-induced micronuclei between HE and ME cells. These results suggest that the response to oxygen change differs markedly in HE and rodent cells. (author)

  2. Effect of low oxygen tension on the biological characteristics of human bone marrow mesenchymal stem cells.

    Science.gov (United States)

    Kim, Dae Seong; Ko, Young Jong; Lee, Myoung Woo; Park, Hyun Jin; Park, Yoo Jin; Kim, Dong-Ik; Sung, Ki Woong; Koo, Hong Hoe; Yoo, Keon Hee

    2016-11-01

    Culture of mesenchymal stem cells (MSCs) under ambient conditions does not replicate the low oxygen environment of normal physiological or pathological states and can result in cellular impairment during culture. To overcome these limitations, we explored the effect of hypoxia (1 % O 2 ) on the biological characteristics of MSCs over the course of different culture periods. The following biological characteristics were examined in human bone marrow-derived MSCs cultured under hypoxia for 8 weeks: proliferation rate, morphology, cell size, senescence, immunophenotypic characteristics, and the expression levels of stemness-associated factors and cytokine and chemokine genes. MSCs cultured under hypoxia for approximately 2 weeks showed increased proliferation and viability. During long-term culture, hypoxia delayed phenotypic changes in MSCs, such as increased cell volume, altered morphology, and the expression of senescence-associated-β-gal, without altering their characteristic immunophenotypic characteristics. Furthermore, hypoxia increased the expression of stemness and chemokine-related genes, including OCT4 and CXCR7, and did not decrease the expression of KLF4, C-MYC, CCL2, CXCL9, CXCL10, and CXCR4 compared with levels in cells cultured under normoxia. In conclusion, low oxygen tension improved the biological characteristics of MSCs during ex vivo expansion. These data suggest that hypoxic culture could be a useful method for increasing the efficacy of MSC cell therapies.

  3. Variations in tumour oxygen tension (pO2) during accelerated radiotherapy of head and neck carcinoma

    International Nuclear Information System (INIS)

    Guichard, M.; Eschwege, F.; Luboinski, B.; Wibault, P.; Weeger, P.; Lusinchi, A.; Lartigau, E.

    1998-01-01

    The study was performed to assess the effect of accelerated radiotherapy on oxygenation of primary tumours and metastatic nodes in patients with advanced head and neck tumours. In 14 patients with head and neck tumour, oxygen tension (pO 2 ) was evaluated in normal tissues and tumours (primary tumour or metastatic neck node) before (0 Gy) and after 2 weeks (32 Gy) of accelerated radiotherapy (70 Gy in 3.5 weeks, with three daily fractions). Radiotherapy was combined with carbogen breathing in 5 patients. pO 2 was measured using a polarographic technique. For pooled normal tissues, median pO 2 was 38 mmHg before treatment and 46 mmHg after 2 weeks. For tumours, very low values ( 2 12 mmHg before treatment versus 26 mmHg after 2 weeks, P 2 was 44 mmHg at 2 weeks, compared with 13.5 mmHg before treatment (P=0.05). Very low pO 2 values, corresponding to tumour hypoxia, were found in the tumours (primary and metastatic neck nodes) prior to accelerated treatment. During the first 2 weeks of accelerated treatment, an increase in median pO 2 was found in nine of the 14 tumours, together with a decrease in the frequency of very low values. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  4. Evaluation of the clamping force in high tension bolt by using the ultrasonic nonlinearity

    International Nuclear Information System (INIS)

    Jang, Kyung Young; Cheon, Hae Wha; Ha, Hob; Park, Man Sick; Kim, No You

    2005-01-01

    High tension bolts have been used widely for the clamping of many kinds of large structure. Therefore, its estimation has been regarded as main issue in the maintenance of high tension bolts. This paper proposes a novel method using the ultrasonic nonlinearity, which is based on the dependency of sound speed on the stress. For this we introduce nonlinear elastic constants in the stress-strain relationship, and derive the sound speed as a linear function of stress. In order to verify the usefulness of the proposed method, two kinds of experiments are carried out: The first one is to measure the sound speed when the bolt is stressed by the tension tester. The result showed good agreement with the expected linear relationship between the sound speed and the axial stress. The second one is to measure the sound speed when the bolt is stressed by the torque wrench. The results showed that the sound speed was decreased when the torque was increased. From these results we can say that the proposed method is enough useful to evaluate the clamping force in the high tension bolt.

  5. [Extensive injuries due to high-tension electrical current].

    Science.gov (United States)

    Tomásek, D; Königová, R; Snupárek, Z

    1989-03-01

    The authors submit a case of severe injury with high tension electric current. They emphasize the necessity of prevention of this injury which occurs most frequently when transformer stations are not adequately safeguarded, in case of inadequate protection when approaching trolley wires on the railway track, and when safety principles are not respected during work on the railway. The authors draw attention to the importance of immediate resuscitation and multidisciplinary comprehensive care.

  6. Inadequate cerebral oxygen delivery and central fatigue during strenuous exercise

    DEFF Research Database (Denmark)

    Nybo, Lars; Rasmussen, Peter

    2007-01-01

    Under resting conditions, the brain is protected against hypoxia because cerebral blood flow increases when the arterial oxygen tension becomes low. However, during strenuous exercise, hyperventilation lowers the arterial carbon dioxide tension and blunts the increase in cerebral blood flow, which...... can lead to an inadequate oxygen delivery to the brain and contribute to the development of fatigue....

  7. Quantifying oxygen in paper-based cell cultures with luminescent thin film sensors.

    Science.gov (United States)

    Boyce, Matthew W; Kenney, Rachael M; Truong, Andrew S; Lockett, Matthew R

    2016-04-01

    Paper-based scaffolds are an attractive material for generating 3D tissue-like cultures because paper is readily available and does not require specialized equipment to pattern, cut, or use. By controlling the exchange of fresh culture medium with the paper-based scaffolds, we can engineer diffusion-dominated environments similar to those found in spheroids or solid tumors. Oxygen tension directly regulates cellular phenotype and invasiveness through hypoxia-inducible transcription factors and also has chemotactic properties. To date, gradients of oxygen generated in the paper-based cultures have relied on cellular response-based readouts. In this work, we prepared a luminescent thin film capable of quantifying oxygen tensions in apposed cell-containing paper-based scaffolds. The oxygen sensors, which are polystyrene films containing a Pd(II) tetrakis(pentafluorophenyl)porphyrin dye, are photostable, stable in culture conditions, and not cytotoxic. They have a linear response for oxygen tensions ranging from 0 to 160 mmHg O2, and a Stern-Volmer constant (K sv) of 0.239 ± 0.003 mmHg O2 (-1). We used these oxygen-sensing films to measure the spatial and temporal changes in oxygen tension for paper-based cultures containing a breast cancer line that was engineered to constitutively express a fluorescent protein. By acquiring images of the oxygen-sensing film and the fluorescently labeled cells, we were able to approximate the oxygen consumption rates of the cells in our cultures.

  8. Influence of oxygen at high pressure on the induction of damage in barley seeds by gamma radiation

    International Nuclear Information System (INIS)

    Donaldson, E.; Nilan, R.A.; Konzak, C.F.

    1978-01-01

    The influence of oxygen pressure prior to, during, and after irradiation on the induction of radiation damage was investigated using Himalaya (C.I. 620) barley seeds. Seeds were adjusted to water contents of 2 to 14% and then irradiated with 60 Co gamma rays in vacuo or under various oxygen tensions. After irradiation, the seeds were rehydrated at approximately 0 0 C in water continuously bubbled with oxygen or nitrogen. Biological effects of the treatments were recorded as M 1 seedling injury. Seeds irradiated in oxygen pressure sustained two or three times more damage than those irradiated in vacuo followed by rehydrating in oxygenated water. Greater damage occurred when seeds were (a) exposed to oxygen pressure and the pressure released before irradiation, (b) irradiated under oxygen pressure, or (c) irradiated in vacuo and then exposed to oxygen pressure than when irradiated in vacuo and rehydrated in oxygenated water. These results suggest that seeds can be saturated with oxygen before irradiation and also that the radiation-induced sites (presumably free radicals) which react with the oxygen are somewhat stable in very dry seeds. That the reaction probably occurs before the seeds are rehydrated was demonstrated by the failure to remove the effect of oxygen pressure between high oxygen pressure treatment and irradiation. The results indicate that placing the seeds under oxygen pressure may increase the rate and extent of the reactions occurring during post-radiation storage of seeds in the presence of oxygen. The increase in damage associated with aerobic rehydration is partially lost during aerobic storage and is largely pre-empted when seeds are placed under oxygen pressure. The decrease in damage associated with aerobic rehydration is accompanied by an increase in damage occurring with anaerobic rehydration, suggesting that the reaction which leads to damage was initiated before rehydration and to the same oxygen sensitive sites

  9. The Neuroprotection Effect of Oxygen Therapy: A Systematic Review ...

    African Journals Online (AJOL)

    2018-04-04

    Apr 4, 2018 ... investigating the neuroprotective effect of oxygen, but the outcomes as well as ...... Neuroprotective gases – Fantasy or reality for clinical use? Prog .... of oxygen on brain tissue oxygen tension in children with severe traumatic ...

  10. Oxygen-controlled automated neural differentiation of mouse embryonic stem cells.

    Science.gov (United States)

    Mondragon-Teran, Paul; Tostoes, Rui; Mason, Chris; Lye, Gary J; Veraitch, Farlan S

    2013-03-01

    Automation and oxygen tension control are two tools that provide significant improvements to the reproducibility and efficiency of stem cell production processes. the aim of this study was to establish a novel automation platform capable of controlling oxygen tension during both the cell-culture and liquid-handling steps of neural differentiation processes. We built a bespoke automation platform, which enclosed a liquid-handling platform in a sterile, oxygen-controlled environment. An airtight connection was used to transfer cell culture plates to and from an automated oxygen-controlled incubator. Our results demonstrate that our system yielded comparable cell numbers, viabilities, metabolism profiles and differentiation efficiencies when compared with traditional manual processes. Interestingly, eliminating exposure to ambient conditions during the liquid-handling stage resulted in significant improvements in the yield of MAP2-positive neural cells, indicating that this level of control can improve differentiation processes. This article describes, for the first time, an automation platform capable of maintaining oxygen tension control during both the cell-culture and liquid-handling stages of a 2D embryonic stem cell differentiation process.

  11. Effect of tension lap splice on the behavior of high strength concrete (HSC beams

    Directory of Open Access Journals (Sweden)

    Ahmed El-Azab

    2014-12-01

    Full Text Available In the recent years, many research efforts have been carried out on the bond strength between normal strength concrete (NSC and reinforcing bars spliced in tension zones in beams. Many codes gave a minimum splice length for tension and compression reinforcement as a factor of the bar diameter depending on many parameters such as concrete strength, steel yield stress, shape of bar end, shape of bar surface and also bar location. Also, codes gave another restriction about the percentage of total reinforcement to be spliced at the same time. Comparatively limited attention has been directed toward the bond between high strength concrete (HSC and reinforcing bars spliced in tension zones in beams. HSC has high modulus of elasticity, high density and long-term durability. This research presents an experimental study on the bond between high strength concrete (HSC and reinforcing bars spliced in tension zones in beams. It reports the influence of several parameters on bond in splices. The parameters covered are casting position, splice length as a factor of bar diameter, bar diameter and reinforcement ratio. The research involved tests on sixteen simply-supported beams of 1800 mm span, 200 mm width and 400 mm thickness made of HSC. In each beam, the total tensile steel bars were spliced in the constant moment zone. Crack pattern, crack propagation, cracking load, failure load and mi span deflection were recorded and analyzed to study the mentioned parameters effect.

  12. Unchanged cerebral blood flow and oxidative metabolism after acclimatization to high altitude

    DEFF Research Database (Denmark)

    Møller, Kirsten; Paulson, Olaf B; Hornbein, Thomas F.

    2002-01-01

    The authors investigated the effect of acclimatization to high altitude on cerebral blood flow and oxidative metabolism at rest and during exercise. Nine healthy, native sea-level residents were studied 3 weeks after arrival at Chacaltaya, Bolivia (5,260 m) and after reacclimatization to sea level....... At high altitude at rest, arterial carbon dioxide tension, oxygen saturation, and oxygen tension were significantly reduced, and arterial oxygen content was increased because of an increase in hemoglobin concentration. Global cerebral blood flow was similar in the four conditions. Cerebral oxygen delivery...... and cerebral metabolic rates of oxygen and glucose also remained unchanged, whereas cerebral metabolic rates of lactate increased slightly but nonsignificantly at high altitude during exercise compared with high altitude at rest. Reaction time was unchanged. The data indicate that cerebral blood flow...

  13. [Case of tension pneumothorax associated with asthma attack during general anesthesia].

    Science.gov (United States)

    Komasawa, Nobuyasu; Ueki, Ryusuke; Kusuyama, Kazuki; Okano, Yukari; Tatara, Tsuneo; Tashiro, Chikara

    2010-05-01

    We report a case of tension pneumothorax associated with asthma attack during general anesthesia. An 86-year-old woman with dementia underwent cataract surgery under general anesthesia. At 70 min after the start of operation, airway pressure suddenly increased from 19 to 28 cm HO2O. In spite of bag ventilation with 100% oxygen, Sp(O2) decreased to 81%. Chest-Xp showed typical image of tension pneumothorax. Chest drainage was immediately performed, after which Pa(O2) recovered soon. She was extubated on postoperative day 1 without any neurological disorder. Hyperinflation of fragile alveoli by mechanical ventilation was likely a cause of tension pneumothorax.

  14. Intraoperative transfusion threshold and tissue oxygenation

    DEFF Research Database (Denmark)

    Nielsen, K; Dahl, B; Johansson, P I

    2012-01-01

    Transfusion with allogeneic red blood cells (RBCs) may be needed to maintain oxygen delivery during major surgery, but the appropriate haemoglobin (Hb) concentration threshold has not been well established. We hypothesised that a higher level of Hb would be associated with improved subcutaneous...... oxygen tension during major spinal surgery....

  15. Encouraging effects of a short-term, adapted Nordic diet intervention on skin microvascular function and skin oxygen tension in younger and older adults.

    Science.gov (United States)

    Rogerson, David; McNeill, Scott; Könönen, Heidi; Klonizakis, Markos

    2018-05-01

    The microvascular benefits of regional diets appear in the literature; however, little is known about Nordic-type diets. We investigated the effects of a short-term, adapted, Nordic diet on microvascular function in younger and older individuals at rest and during activity. Thirteen young (mean age: 28 y; standard deviation: 5 y) and 15 older (mean age: 68 y; standard deviation: 6 y) participants consumed a modified Nordic diet for 4 wk. Laser Doppler flowmetry and transcutaneous oxygen monitoring were used to assess cutaneous microvascular function and oxygen tension pre- and postintervention; blood pressure, body mass, body fat percentage, ratings of perceived exertion, and peak heart rate during activity were examined concurrently. Axon-mediated vasodilation improved in older participants (1.17 [0.30] to 1.30 [0.30]; P Nordic diet might improve microvascular health. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Differences of optic disc appearance between normal tension and high tension glaucoma patients

    Directory of Open Access Journals (Sweden)

    Stojčić Milan

    2011-01-01

    Full Text Available Introduction. The term glaucoma is used to cover a wide range of diseases, whose main feature is optic neuropathy. According to the level of intraocular pressure (IOP, the open angle glaucoma is arbitrarily divided into high tension glaucoma (HTG and normal tension glaucoma (NTG. Objective. The aim of this study was to investigate the differences of optic disc cup appearance between patients with NTG and HTG. Methods. Prospective study included 30 patients (60 eyes with NTG and 30 patients (60 eyes with HTG. IOP was measured by Goldmann applanation tonometry. Examination of optic disc head was performed by indirect ophthalmoscopy with Volk 90 D superfield lens through a dilated pupil to observe qualitative and quantitative parameters. Visual fields were examined in all patients with the Octopus program G1, full threshold strategy (Octopus 500 EZ, Interzeag, Switzerland. Results. Vertical form of optic disc cup was present in 11 eyes with NTG (18.3% and three eyes with HTG (5% (p<0.05. A disc with localized tissue loss (polar notching on the inferior pole was observed in eight eyes with NTG (13.3% and in one eye with HTG (1.7% (p<0.01. Uniformly enlarged, round cup was more frequent in patients with HTG than NTG: 93.3% and 68.3% respectively (p<0.05. Conclusion. The perceived differences indicate a complex multifactorial nature of glaucoma disease and a possible existence of two pathophysiological ways of optic disc changes within the same basic disease.

  17. High-tension electrical-arc-induced thermal burns caused by railway overhead cables.

    Science.gov (United States)

    Koller, J

    1991-10-01

    Eleven patients with high-tension electrical-arc-induced thermal burns due to railway overhead cables were treated at the Bratislava Burn Department during a relatively short period of 18 months. All the injuries occurred by the same mechanism, that is persons climbing on top of railway carriages and approaching the 25,000 V a.c. overhead cables. All the burns were the result of an electrical arc passing externally to the body, with subsequent ignition of the victim's clothes. The cutaneous burns, ranging from 24 to 79 per cent of the BSA, were mostly deep partial to full skin thickness injuries. One patient died on day 5 postburn, the other survived. In spite of high-tension aetiology, no true electrical injuries appear to have occurred and no amputations were necessary. The pathophysiology and possible preventive measures are discussed. It must be stressed that arcing can be induced by an earthed object approaching, but not touching, a cable carrying a high voltage.

  18. Matrix stiffness and oxigen tension modulate epigenetic conversion of mouse dermal fibroblasts into insulin producing cells.

    Directory of Open Access Journals (Sweden)

    Alessandro Zenobi

    2017-05-01

    Full Text Available In vivo, cells are surrounded by a three-dimensional (3-D organization of supporting matrix, neighboring cells and a gradient of chemical and mechanical signals (Antoni, et al., 2015. However, the present understanding of many biological processes is mainly based on two-dimensional (2-D systems that typically provides a static environment. In the present study, we tested two different 3-D culture systems and apply them to the epigenetic conversion of mouse dermal fibroblasts into insulin producing-cells (Pennarossa, et al., 2013; Brevini, et al., 2015, combining also the use of two oxygen tensions. In particular, cells were differentiated using the Polytetrafluoroethylene micro-bioreactor (PTFE and the Polyacrylamide (PAA gels with different stiffness (1 kPa; 4 kPa, maintained either in the standard 20% or in the more physiological 5% oxygen tensions. Standard differentiation performed on plastic substrates was assessed as a control. Cell morphology (Fig.1A, insulin expression and release were analyzed to evaluate the role of both stiffness and oxygen tension in the process. The results obtained showed that 1 kPa PAA gel and PTFE system induced a significantly higher insulin expression and release than plastic and 4 kPa PAA gel, especially in low oxygen condition (Fig.1B. Furthermore, comparing the efficiency of the two systems tested, 1 kPa PAA gel ensured a higher insulin transcription than PTFE (Fig.1C. Recent studies show the direct influence of substrates on lineage commitment and cell differentiation (Engler, et al., 2006; Evans, et al., 2009. The evidence here presented confirm that the use of an appropriate stiffness (similar to the pancreatic tissue, combined with a physiological oxygen tension, promote β-cell differentiation, with beneficial effects on cell functional activity and insulin release. The present results highlight the importance of 3-D cell rearrangement and oxigen tension to promote in vitro epigenetic conversion of

  19. High Selectivity Oxygen Delignification

    Energy Technology Data Exchange (ETDEWEB)

    Arthur J. Ragauskas

    2005-09-30

    The overall objective of this program was to develop improved extended oxygen delignification (EOD) technologies for current U.S. pulp mill operations. This was accomplished by: (1) Identifying pulping conditions that optimize O and OO performance; (2) Identifying structural features of lignin that enhance reactivity towards EOD of high kappa pulps; (3) Identifying factors minimizing carbohydrate degradation and improve pulp strength of EOD high kappa pulps; (4) Developing a simple, reproducible method of quantifying yield gains from EOD; and (5) Developing process conditions that significantly reduce the capital requirements of EOD while optimizing the yield benefits. Key research outcomes included, demonstrating the use of a mini-O sequence such as (E+O)Dkf:0.05(E+O) or Dkf:0.05(E+O)(E+O) without interstage washing could capture approximately 60% of the delignification efficiency of a conventional O-stage without the major capital requirements associated with an O-stage for conventional SW kraft pulps. The rate of formation and loss of fiber charge during an O-stage stage can be employed to maximize net fiber charge. Optimal fiber charge development and delignification are two independent parameters and do not parallel each other. It is possible to utilize an O-stage to enhance overall cellulosic fiber charge of low and high kappa SW kraft pulps which is beneficial for physical strength properties. The application of NIR and multi-variant analysis was developed into a rapid and simple method of determining the yield of pulp from an oxygen delignification stage that has real-world mill applications. A focus point of this program was the demonstration that Kraft pulping conditions and oxygen delignification of high and low-kappa SW and HW pulps are intimately related. Improved physical pulp properties and yield can be delivered by controlling the H-factor and active alkali charge. Low AA softwood kraft pulp with a kappa number 30 has an average improvement of 2% in

  20. Bilateral tension pneumothorax related to acupuncture.

    Science.gov (United States)

    Tagami, Rumi; Moriya, Takashi; Kinoshita, Kosaku; Tanjoh, Katsuhisa

    2013-06-01

    We report on a patient with a rare case of bilateral tension pneumothorax that occurred after acupuncture. A 69-year-old large-bodied man, who otherwise had no risk factors for spontaneous pneumothorax, presented with chest pressure, cold sweats and shortness of breath. Immediately after bilateral pneumothorax had been identified on a chest radiograph in the emergency room, his blood pressure and percutaneous oxygen saturation suddenly decreased to 78 mm Hg and 86%, respectively. We confirmed deterioration in his cardiopulmonary status and diagnosed bilateral tension pneumothorax. We punctured his chest bilaterally and inserted chest tubes for drainage. His vital signs promptly recovered. After the bilateral puncture and drainage, we learnt that he had been treated with acupuncture on his upper back. We finally diagnosed a bilateral tension pneumothorax based on the symptoms that appeared 8 h after the acupuncture. Because the patient had no risk factors for spontaneous pneumothorax, no alternative diagnosis was proposed. We recommend that patients receiving acupuncture around the chest wall must be adequately informed of the possibility of complications and expected symptoms, as a definitive diagnosis can be difficult without complete information.

  1. Stimulation of growth of the human gastric pathogen Helicobacter pylori by atmospheric level of oxygen under high carbon dioxide tension

    Directory of Open Access Journals (Sweden)

    Lee Na

    2011-05-01

    Full Text Available Abstract Background Helicobacter pylori (Hp, a human pathogen that is associated with gastritis, peptic ulcer, and gastric cancer, has been considered a microaerophile, but there is no general consensus about its specific O2 requirements. A clear understanding of Hp physiology is needed to elucidate the pathogenic mechanism(s of Hp infection. Results We cultured Hp under a range of O2 levels with or without 10% CO2 and evaluated growth profiles, morphology, intracellular pH, and energy metabolism. We found that, in the presence of 10% CO2, the normal atmospheric level of O2 inhibited Hp growth at low density but stimulated growth at a higher density. Field emission scanning electron microscopy and fluorescence microscopy of Hp cells cultured under 20% O2 tension revealed live spiral-shaped bacteria with outer membrane vesicles on a rugged cell surface, which became smooth during the stationary phase. Fermentation products including acetate, lactate, and succinate were detected in cell culture media grown under microaerobic conditions, but not under the aerobic condition. CO2 deprivation for less than 24 h did not markedly change cytoplasmic or periplasmic pH, suggesting that cellular pH homeostasis alone cannot account for the capnophilic nature of Hp. Further, CO2 deprivation significantly increased intracellular levels of ppGpp and ATP but significantly decreased cellular mRNA levels, suggesting induction of the stringent response. Conclusions We conclude, unlike previous reports, that H. pylori may be a capnophilic aerobe whose growth is promoted by atmospheric oxygen levels in the presence of 10% CO2. Our data also suggest that buffering of intracellular pH alone cannot account for the CO2 requirement of H. pylori and that CO2 deprivation initiates the stringent response in H. pylori. Our findings may provide new insight into the physiology of this fastidious human pathogen.

  2. Arterial oxygen tension and pulmonary ventilation in horses placed in the Anderson Sling suspension system after a period of lateral recumbency and anaesthetised with constant rate infusions of romifidine and ketamine.

    Science.gov (United States)

    François, I; Lalèyê, F-X; Micat, M; Benredouane, K; Portier, K

    2014-09-01

    Some controversy exists over whether or not horses' recovery and cardiopulmonary function are affected by suspension in slings. To measure arterial oxygen tension and pulmonary ventilation in anaesthetised horses placed in a standing position in an Anderson Sling (AS) after a period of right lateral recumbency (RLR). Randomised crossover experimental study. Six Standardbred horses were anaesthetised twice. Catheters were inserted into the right jugular vein and the left carotid artery. After premedication with romifidine, anaesthesia was induced with diazepam and ketamine. Following 50 min in RLR, horses were maintained in either RLR or AS for an additional 60 min through to recovery. Anaesthesia was maintained i.v. with a constant rate infusion of romifidine and ketamine. Heart rate, respiratory rate, mean arterial pressure, expiratory tidal volume, minute volumes and end tidal CO2 were monitored continuously. Venous and arterial bloods were sampled for lactate concentration, creatine kinase activity and blood gas analysis before premedication, after induction, every 20 min for 100 min, as soon as the horse was standing (TR), and 24 h later. The data were averaged within 2 anaesthetic periods: P1, 0-20 min; and P2, 40-100 min. During P2, horses in the RLR group had lower arterial oxygen tension (P = 0.001), higher alveolar-arterial oxygen tension gradient (P = 0.005), higher respiratory rate (P = 0.04) and higher minute volumes (P = 0.04) than horses in the AS group. Arterial CO2 tension and mean arterial pressure increased in the AS group during P2 (P = 0.01 and 0.02 respectively). The recoveries were judged better in the AS group than in the RLR group (P = 0.01). During TR, lactate were higher in the RLR group than in the AS group (P = 0.007). Creatine kinase activities were higher in the AS group at 24 h vs. TR (P = 0.02). Anderson Sling suspension after a period of recumbency improves cardiopulmonary function and recovery quality in horses and

  3. The behavior of high-strength unidirectional composites under tension with superposed hydrostatic pressure

    NARCIS (Netherlands)

    Zinoviev, P.A.; Tsvetkov, S.V.; Kulish, G.G.; Berg, van den R.W.; Schepdael, van L.J.M.M.

    2001-01-01

    Three types of high-strength unidirectional composite materials were studied under longitudinal tension with superposed high hydrostatic pressure. Reinforcing fibers were T1000G carbon, S2 glass and Zylon PBO fibers; the Ciba 5052 epoxy resin was used as matrix. The composites were tested under

  4. Radiosensitization of mouse skin by oxygen and depletion of glutathione

    International Nuclear Information System (INIS)

    Stevens, Graham; Joiner, Michael; Joiner, Barbara; Johns, Helen; Denekamp, Juliana

    1995-01-01

    Purpose: To determine the oxygen enhancement ratio (OER) and shape of the oxygen sensitization curve of mouse foot skin, the extent to which glutathione (GSH) depletion radiosensitized skin, and the dependence of such sensitization on the ambient oxygen tension. Methods and Materials: The feet of WHT mice were irradiated with single doses of 240 kVp x-rays while mice were exposed to carbogen or gases with oxygen/nitrogen mixtures containing 8-100% O 2 . The anoxic response was obtained by occluding the blood supply to the leg of anesthetized mice with a tourniquet, surrounding the foot with nitrogen, and allowing the mice to breathe 10% O 2 . Further experiments were performed to assess the efficacy of this method to obtain an anoxic response. Radiosensitivity of skin was assessed using the acute skin-reaction assay. Glutathione levels were modified using two schedules of dl-buthionine sulphoximine (BSO) and diethylmaleate (DEM), which were considered to produce extensive and intermediate levels of GSH depletion in the skin of the foot during irradiation. Results: Carbogen caused the greatest radiosensitization of skin, with a reproducible enhancement of 2.2 relative to the anoxic response. The OER of 2.2 is lower than other reports for mouse skin. This may indicate that the extremes of oxygenation were not produced, although there was no direct evidence for this. When skin radiosensitivity was plotted against the logarithm of the oxygen tension in the ambient gas, a sigmoid curve with a K value of 17-21% O 2 in the ambient gas was obtained. Depletion of GSH caused minimal radiosensitization when skin was irradiated under anoxic or well-oxygenated conditions. Radiosensitization by GSH depletion was maximal at intermediate oxygen tensions of 10-21% O 2 in the ambient gas. Increasing the extent of GSH depletion led to increasing radiosensitization, with sensitization enhancement ratios of 1.2 and 1.1, respectively, for extensive and intermediate levels of GSH

  5. Oxygen transfer rate during the production of alginate by Azotobacter vinelandii under oxygen-limited and non oxygen-limited conditions

    Directory of Open Access Journals (Sweden)

    Peña Carlos F

    2011-02-01

    Full Text Available Abstract Background The oxygen transfer rate (OTR and dissolved oxygen tension (DOT play an important role in determining alginate production and its composition; however, no systematic study has been reported about the independent influence of the OTR and DOT. In this paper, we report a study about alginate production and the evolution of the molecular mass of the polymer produced by a wild-type A. vinelandii strain ATCC 9046, in terms of the maximum oxygen transfer rate (OTRmax in cultures where the dissolved oxygen tension (DOT was kept constant. Results The results revealed that in the two dissolved oxygen conditions evaluated, strictly controlled by gas blending at 0.5 and 5% DOT, an increase in the agitation rate (from 300 to 700 rpm caused a significant increase in the OTRmax (from 17 to 100 mmol L-1 h-1 for DOT of 5% and from 6 to 70 mmol L-1 h-1 for DOT of 0.5%. This increase in the OTRmax improved alginate production, as well as the specific alginate production rate (SAPR, reaching a maximal alginate concentration of 3.1 g L-1 and a SAPR of 0.031 g alg g biom-1 h-1 in the cultures at OTRmax of 100 mmol L-1 h-1. In contrast, the mean molecular mass (MMM of the alginate isolated from cultures developed under non-oxygen limited conditions increased by decreasing the OTRmax, reaching a maximal of 550 kDa at an OTRmax of 17 mmol L-1 h-1 . However, in the cultures developed under oxygen limitation (0.5% DOT, the MMM of the polymer was practically the same (around 200 kDa at 300 and 700 rpm, and this remained constant throughout the cultivation. Conclusions Overall, our results showed that under oxygen-limited and non oxygen-limited conditions, alginate production and its molecular mass are linked to the OTRmax, independently of the DOT of the culture.

  6. Modification of the radiation response of pig skin by manipulation of tissue oxygen tension using anesthetics and administration of BW12C

    International Nuclear Information System (INIS)

    van den Aardweg, G.J.; Hopewell, J.W.; Barnes, D.W.; Sansom, J.M.; Nethersell, A.B.

    1989-01-01

    The importance of tissue oxygen tension on radiosensitivity was studied by examining modifications in the incidence of moist desquamation in pig skin after irradiation with strontium-90 plaques. The effects were analyzed using quantal dose-response data and comparisons were made using ED50 values for moist desquamation. Under standard anesthetic conditions of 2% halothane, approximately 70% oxygen, and approximately 30% nitrous oxide, the ED50 value (+/- SE) for moist desquamation was 27.32 +/- 0.52 Gy with no significant variation in radiosensitivity between dorsal, lateral, and ventral skin sites on the flank. Irradiation with 2% halothane and air increased the ED50 to 31.25 +/- 0.94 Gy, primarily due to an increased radioresistance of the dorsal sites. When combined with BW12C, a drug which binds oxygen selectively to hemoglobin and hence reduced the oxygen availability to tissues, a further increase in the ED50 values was observed. This was approximately 39 Gy with BW12C concentrations of 30 mg/kg and 50 mg/kg b.w. of BW12C, indicating a dose modification factor (DMF) of approximately 1.26. However, when animals were breathing the standard gas mixture, this DMF was reduced to 1.15 for 30 mg/kg of BW12C, indicating that a higher level of oxygen partly counteracted the effects of the drug in these studies with BW12C. The greatest variability in radiosensitivity was seen in the dorsal fields. This suggested complex physiological adaptation, a phenomenon that might also explain the absence of any modification of the radiation response when 100 mg/kg of BW12C was used

  7. Non-invasive high throughput approach for protein hydrophobicity determination based on surface tension.

    Science.gov (United States)

    Amrhein, Sven; Bauer, Katharina Christin; Galm, Lara; Hubbuch, Jürgen

    2015-12-01

    The surface hydrophobicity of a protein is an important factor for its interactions in solution and thus the outcome of its production process. Yet most of the methods are not able to evaluate the influence of these hydrophobic interactions under natural conditions. In the present work we have established a high resolution stalagmometric method for surface tension determination on a liquid handling station, which can cope with accuracy as well as high throughput requirements. Surface tensions could be derived with a low sample consumption (800 μL) and a high reproducibility (content. The protein influence on the solutions' surface tension was correlated to the hydrophobicity of lysozyme, human lysozyme, BSA, and α-lactalbumin. Differences in proteins' hydrophobic character depending on pH and species could be resolved. Within this work we have developed a pH dependent hydrophobicity ranking, which was found to be in good agreement with literature. For the studied pH range of 3-9 lysozyme from chicken egg white was identified to be the most hydrophilic. α-lactalbumin at pH 3 exhibited the most pronounced hydrophobic character. The stalagmometric method occurred to outclass the widely used spectrophotometric method with bromophenol blue sodium salt as it gave reasonable results without restrictions on pH and protein species. © 2015 Wiley Periodicals, Inc.

  8. Hyperbaric oxygen and radiotherapy

    International Nuclear Information System (INIS)

    Mayer, R.; Hamilton-Farrell, M.R.; Kleij, A.J. van der

    2005-01-01

    Background: Hyperbaric oxygen (HBO) therapy is the inhalation of 100% oxygen at a pressure of at least 1.5 atmospheres absolute (150 kPa). It uses oxygen as a drug by dissolving it in the plasma and delivering it to the tissues independent of hemoglobin. For a variety of organ systems, HBO is known to promote new vessel growth into areas with reduced oxygen tension due to poor vascularity, and therewith promotes wound healing and recovery of radiation-injured tissue. Furthermore, tumors may be sensitized to irradiation by raising intratumoral oxygen tensions. Methods: A network of hyperbaric facilities exists in Europe, and a number of clinical studies are ongoing. The intergovernmental framework COST B14 action 'Hyperbaric Oxygen Therapy' started in 1999. The main goal of the Working Group Oncology is preparation and actual implementation of prospective study protocols in the field of HBO and radiation oncology in Europe. Results: In this paper a short overview on HBO is given and the following randomized clinical studies are presented: (a) reirradiation of recurrent squamous cell carcinoma of the head and neck after HBO sensitization; (b) role of HBO in enhancing radiosensitivity on glioblastoma multiforme; (c) osseointegration in irradiated patients; adjunctive HBO to prevent implant failures; (d) the role of HBO in the treatment of late irradiation sequelae in the pelvic region. The two radiosensitization protocols (a, b) allow a time interval between HBO and subsequent irradiation of 10-20 min. Conclusion: Recruitment of centers and patients is being strongly encouraged, detailed information is given on www.oxynet.org. (orig.)

  9. L-lysine escinat, thiotriazolin, gordox and mydocalm influence on oxygen tension in the intestinal wall and acid-base balance and limited proteolysis in intestinal venous blood in terms of intraabdominal hypertension modeling

    Directory of Open Access Journals (Sweden)

    Sapegin V.I.

    2014-11-01

    Full Text Available In acute experiments on rabbits there were studied changes in oxygen tension in the intestinal wall tissues, acid-base balance and limited proteolysis and its inhibitors in intestinal venous blood, protective action of L-lysine escinat (0,15 mg/kg / single dose, thiotriazolin (25 mg/kg / single dose, aprotinin (gordox (10,000 units/kg / single dose in sequential modeling of standard levels increasing of intra-abdominal hypertension (IAH — 50, 100, 150, 200, 250, 300, 350 m H2O, and also of tolperison (mydocalm (5 mg/kg / single dose on modeling of stable 3-hour IAH 200 m H2O. The IAH modeling was performed by means of stand of our construction. Under the influence of IAH the compensated metabolic acidosis in intestinal venous blood with a compensative hyperpnoe develops, decline of oxygen tension in tissues and activating of a limited proteolysis as well as decline of its inhibitors activity in intestinal venous blood occur. By the degree of metabolic acidosis prevention investigational preparations were distributed as follows gordox > thiotriazolin = L-lysine escinat = mydocalm, and by prevention of decline of oxygen tension in tissues — thiotriazolin > L-lysine escinat > mydocalm > gordox, it is is connected with different rate of methabolic products excretion into the blood, due to the influence on blood circulation and transcapilary exchange. By the degree of prevention of proteolytic activity and inhibitory potential changes, investigational preparations were distributed as follows: gordox > mydocalm > thiotriazolin > L-lysine escinat, this is connected with inhibition of proteolysis in gordox, and in other ones – with reduction of ischemic damage of tissues. Owing to different mechanism of action thiotriazolin, L-lysine escinat and mydocalm may be simultaneously recommended for a conservative treatment of patients with intraabdominal hypertension syndrome.

  10. Simultaneous Monitoring of Vascular Oxygenation and Tissue Oxygen Tension of Breast Tumors Under Hyperbaric Oxygen Exposure

    National Research Council Canada - National Science Library

    Xia, Mengna

    2005-01-01

    The goals of the study in the first stage are 1) to develop a mathematic model by which we can derive tumor blood flow and metabolic rate of oxygen from hemoglobin concentration during interventions, 2...

  11. Robust high temperature oxygen sensor electrodes

    DEFF Research Database (Denmark)

    Lund, Anders

    Platinum is the most widely used material in high temperature oxygen sensor electrodes. However, platinum is expensive and the platinum electrode may, under certain conditions, suffer from poisoning, which is detrimental for an oxygen sensor. The objective of this thesis is to evaluate electrode...... materials as candidates for robust oxygen sensor electrodes. The present work focuses on characterising the electrochemical properties of a few electrode materials to understand which oxygen electrode processes are limiting for the response time of the sensor electrode. Three types of porous platinum......-Dansensor. The electrochemical properties of the electrodes were characterised by electrochemical impedance spectroscopy (EIS), and the structures were characterised by x-ray diffraction and electron microscopy. At an oxygen partial pressures of 0.2 bar, the response time of the sensor electrode was determined by oxygen...

  12. The insulation condition diagnosis of high tension generator stators; Diagnostico del estado de aislamiento de estatores de generadores de alta tension

    Energy Technology Data Exchange (ETDEWEB)

    Robles Pimentel, Edgar Guillermo; Rosales Sedano, Inocente [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1990-12-31

    The high tension electrical generators are very high cost equipment, therefore they need to be very reliable. The generators preventive maintenance based in diagnosis techniques of the insulation condition might mean substantial savings for the user. In this article the most common techniques employed all over the world are presented, the greatest part of them already implemented in Mexico by the authors. The techniques and the equipment employed are analyzed and are exemplified with the results obtained in some field experiences. [Espanol] Los generadores electricos de alta tension son equipos de muy alto costo, por lo que necesitan ser muy confiables. El mantenimiento preventivo de los generadores basado en tecnicas de diagnostico del estado del aislamiento puede significar ahorros sustanciales al usuario. En este articulo se presentan las tecnicas mas comunes empleadas en el mundo, la mayor parte de ellas ya implantadas en Mexico por los autores. Se analizan las tecnicas y el equipo empleado, y se ejemplifica con resultados obtenidos de algunas de las experiencias en el campo.

  13. The insulation condition diagnosis of high tension generator stators; Diagnostico del estado de aislamiento de estatores de generadores de alta tension

    Energy Technology Data Exchange (ETDEWEB)

    Robles Pimentel, Edgar Guillermo; Rosales Sedano, Inocente [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1989-12-31

    The high tension electrical generators are very high cost equipment, therefore they need to be very reliable. The generators preventive maintenance based in diagnosis techniques of the insulation condition might mean substantial savings for the user. In this article the most common techniques employed all over the world are presented, the greatest part of them already implemented in Mexico by the authors. The techniques and the equipment employed are analyzed and are exemplified with the results obtained in some field experiences. [Espanol] Los generadores electricos de alta tension son equipos de muy alto costo, por lo que necesitan ser muy confiables. El mantenimiento preventivo de los generadores basado en tecnicas de diagnostico del estado del aislamiento puede significar ahorros sustanciales al usuario. En este articulo se presentan las tecnicas mas comunes empleadas en el mundo, la mayor parte de ellas ya implantadas en Mexico por los autores. Se analizan las tecnicas y el equipo empleado, y se ejemplifica con resultados obtenidos de algunas de las experiencias en el campo.

  14. High-tension corona controlled ozone generator for environment protection

    International Nuclear Information System (INIS)

    Vijayan, T; Patil, Jagadish G

    2010-01-01

    Engineering details of a high voltage driven corona-plasma ozone generator are described. The plasma diode of generator has coaxial cylindrical geometry with cathode located inside anode. Cathode is made of a large number of radial gas nozzles arranged on central tubular mast which admits oxygen gas. The sharp endings of the nozzles along with a set of corona rings create the high electric field at the cathode required for formation of dense corona plume responsible for O 3 evolution. A model of coronal plasma generation and ozone production is presented. The plasma formation is strongly dependent on the electric field and temperature in side diode where a high electron density in a low temperature negative corona is suited for high ozone yields. These are established by suitable regulation of A-K gap, voltage, oxygen pressure, and cathode-nozzle population.

  15. Prediction of inspired oxygen fraction for targeted arterial oxygen tension following open heart surgery in non-smoking and smoking patients.

    Science.gov (United States)

    Bou-Khalil, Pierre; Zeineldine, Salah; Chatburn, Robert; Ayyoub, Chakib; Elkhatib, Farouk; Bou-Akl, Imad; El-Khatib, Mohamad

    2017-10-01

    Simple and accurate expressions describing the P a O 2 -F i O 2 relationship in mechanically ventilated patients are lacking. The current study aims to validate a novel mathematical expression for accurate prediction of the fraction of inspired oxygen that will result in a targeted arterial oxygen tension in non-smoking and smoking patients receiving mechanical ventilation following open heart surgeries. One hundred P a O 2 -F i O 2 data pairs were obtained from 25 non-smoking patients mechanically ventilated following open heart surgeries. One data pair was collected at each of F i O 2 of 40, 60, 80, and 100% while maintaining same mechanical ventilation support settings. Similarly, another 100 hundred P a O 2 -F i O 2 data pairs were obtained from 25 smoking patients mechanically ventilated following open heart surgeries. The utility of the new mathematical expression in accurately describing the P a O 2 -F i O 2 relationship in these patients was assessed by the regression and Bland-Altman analyses. Significant correlations were seen between the true and estimated F i O 2 values in non-smoking (r 2  = 0.9424; p < 0.05) and smoking (r 2  = 0.9466; p < 0.05) patients. Tight biases between the true and estimated F i O 2 values for non-smoking (3.1%) and smoking (4.1%) patients were observed. Also, significant correlations were seen between the true and estimated P a O 2 /F i O 2 ratios in non-smoking (r 2  = 0.9530; p < 0.05) and smoking (r 2  = 0.9675; p < 0.05) patients. Tight biases between the true and estimated P a O 2 /F i O 2 ratios for non-smoking (-18 mmHg) and smoking (-16 mmHg) patients were also observed. The new mathematical expression for the description of the P a O 2 -F i O 2 relationship is valid and accurate in non-smoking and smoking patients who are receiving mechanical ventilation for post cardiac surgery.

  16. Introduction of high oxygen concentrations into silicon wafers by high-temperature diffusion

    International Nuclear Information System (INIS)

    Casse, G.; Glaser, M.; Lemeilleur, F.; Ruzin, A.; Wegrzecki, M.

    1999-01-01

    The tolerance of silicon detectors to hadron irradiation can be improved by the introduction of a high concentration of oxygen into the starting material. High-resistivity Floating-Zone (FZ) silicon is required for detectors used in particle physics applications. A significantly high oxygen concentration (>10 17 atoms cm -3 ) cannot readily be achieved during the FZ silicon refinement. The diffusion of oxygen at elevated temperatures from a SiO 2 layer grown on both sides of a silicon wafer is a simple and effective technique to achieve high and uniform concentrations of oxygen throughout the bulk of a 300 μm thick silicon wafer

  17. Capillary-oxygenation-level-dependent near-infrared spectrometry in frontal lobe of humans

    NARCIS (Netherlands)

    Rasmussen, Peter; Dawson, Ellen A.; Nybo, Lars; van Lieshout, Johannes J.; Secher, Niels H.; Gjedde, Albert

    2007-01-01

    Brain function requires oxygen and maintenance of brain capillary oxygenation is important. We evaluated how faithfully frontal lobe near-infrared spectroscopy (NIRS) follows haemoglobin saturation (SCap) and how calculated mitochondrial oxygen tension (PMitoO2) influences motor performance. Twelve

  18. Cerebral oxygenation is reduced during hyperthermic exercise in humans

    DEFF Research Database (Denmark)

    Rasmussen, Peter; Nybo, Lars; Volianitis, S.

    2010-01-01

    Abstract Aim: Cerebral mitochondrial oxygen tension (P(mito)O(2)) is elevated during moderate exercise, while it is reduced when exercise becomes strenuous, reflecting an elevated cerebral metabolic rate for oxygen (CMRO(2)) combined with hyperventilation-induced attenuation of cerebral blood flo...

  19. Mentoring Preservice Teachers: Identifying Tensions and Possible Resolutions

    Science.gov (United States)

    Hudson, Peter; Hudson, Sue

    2018-01-01

    Tensions can occur in the mentor-mentee relationship during school-based professional experiences that require problem solving. What are the tensions for mentor teachers in preservice teacher education and how might these tensions be resolved? This qualitative study collected data from 31 high school mentor teachers about tensions experienced with…

  20. High oxygen condition facilitates the differentiation of mouse and human pluripotent stem cells into pancreatic progenitors and insulin-producing cells.

    Science.gov (United States)

    Hakim, Farzana; Kaitsuka, Taku; Raeed, Jamiruddin Mohd; Wei, Fan-Yan; Shiraki, Nobuaki; Akagi, Tadayuki; Yokota, Takashi; Kume, Shoen; Tomizawa, Kazuhito

    2014-04-04

    Pluripotent stem cells have potential applications in regenerative medicine for diabetes. Differentiation of stem cells into insulin-producing cells has been achieved using various protocols. However, both the efficiency of the method and potency of differentiated cells are insufficient. Oxygen tension, the partial pressure of oxygen, has been shown to regulate the embryonic development of several organs, including pancreatic β-cells. In this study, we tried to establish an effective method for the differentiation of induced pluripotent stem cells (iPSCs) into insulin-producing cells by culturing under high oxygen (O2) conditions. Treatment with a high O2 condition in the early stage of differentiation increased insulin-positive cells at the terminus of differentiation. We found that a high O2 condition repressed Notch-dependent gene Hes1 expression and increased Ngn3 expression at the stage of pancreatic progenitors. This effect was caused by inhibition of hypoxia-inducible factor-1α protein level. Moreover, a high O2 condition activated Wnt signaling. Optimal stage-specific treatment with a high O2 condition resulted in a significant increase in insulin production in both mouse embryonic stem cells and human iPSCs and yielded populations containing up to 10% C-peptide-positive cells in human iPSCs. These results suggest that culturing in a high O2 condition at a specific stage is useful for the efficient generation of insulin-producing cells.

  1. Effects of acetazolamide on cerebral blood flow and brain tissue oxygenation

    DEFF Research Database (Denmark)

    Lassen, N A; Friberg, L; Kastrup, J

    1987-01-01

    Oral administration of 1 g of acetazolamide to 8 normal subjects studied at sea level and in normoxia caused an acute increase in cerebral blood flow (CBF). During the subsequent prolonged oral treatment with 1 g of acetazolamide daily, CBF returned to normal within 2 days. The alveolar CO2 tension...... decreased gradually to 70% of the control value, indicating hyperventilation. At sea level hyperventilation will not increase brain oxygenation significantly in normal man, as the arterial oxygen content only increases minimally, while CBF is unchanged. At high altitude the beneficial effects...... of acetazolamide on the symptoms of acute mountain sickness may well be due to an improved oxygen supply to the brain, as hyperventilation will, at the low ambient PO2, cause a significant increase of the arterial oxygen content, while CBF presumably is unaffected by the drug. During hypoxia at high altitude...

  2. Interfacial tension measurement between CO2 and brines under high temperature and elevated pressure conditions

    Science.gov (United States)

    Li, X.; Boek, E. S.; Maitland, G. C.; Trusler, J. P. M.

    2012-04-01

    We have investigated the dependence of interfacial tension of (CO2 + brine) on temperature, pressure and salinity (including both salt type and molality) over the range of conditions applicable to CO2 storage in saline aquifers. The study covered a wide range of measurements of the interfacial tensions between carbon dioxide and (NaCl + KCl)(aq), CaCl2(aq), MgCl2(aq), Na2SO4(aq), KHCO3(aq), NaHCO3(aq) and two laboratory constructed brines with molality ranging from (0.3 to 5.0) mol·kg-1. The measurements were made at temperatures between (298 and 448) K at various pressures up to 50 MPa, using the pendant drop method in a high-pressure view cell filled with water-saturated CO2. The drop to be imaged was created by injecting brine from a high-pressure syringe pump into a capillary sealed through the top of the cell. The expanded uncertainties of the experimental state variables at 95 % confidence are +0.05 K in temperature and +70 kPa in pressure. For the interfacial tension, the overall expanded relative uncertainty at 95 % confidence was +1.6%. The experimental results show that interfacial tension for all the systems increases linearly with molality, indicating that relatively few measurements and simple interpolation procedures are adequate for describing this property accurately over wide ranges of conditions.

  3. A theoretical model for oxygen transport in skeletal muscle under conditions of high oxygen demand.

    Science.gov (United States)

    McGuire, B J; Secomb, T W

    2001-11-01

    Oxygen transport from capillaries to exercising skeletal muscle is studied by use of a Krogh-type cylinder model. The goal is to predict oxygen consumption under conditions of high demand, on the basis of a consideration of transport processes occurring at the microvascular level. Effects of the decline in oxygen content of blood flowing along capillaries, intravascular resistance to oxygen diffusion, and myoglobin-facilitated diffusion are included. Parameter values are based on human skeletal muscle. The dependence of oxygen consumption on oxygen demand, perfusion, and capillary density are examined. When demand is moderate, the tissue is well oxygenated and consumption is slightly less than demand. When demand is high, capillary oxygen content declines rapidly with axial distance and radial oxygen transport is limited by diffusion resistance within the capillary and the tissue. Under these conditions, much of the tissue is hypoxic, consumption is substantially less than demand, and consumption is strongly dependent on capillary density. Predicted consumption rates are comparable with experimentally observed maximal rates of oxygen consumption.

  4. Oxygen status during haemodialysis. The Cord-Group

    DEFF Research Database (Denmark)

    Nielsen, A L; Jensen, H Æ; Hegbrant, J

    1995-01-01

    Hypoxia during haemodialysis, mainly acetate, has been reported several times. In our study we have monitored oxygen status during 258 bicarbonate haemodialyses. A significant drop below 80 mmHg in mean oxygen tension occurred. Mean oxygen saturation reflected this drop but did not reach levels...... below 90%. The mean oxygen concentration was on the whole critical low, though slightly increasing during each haemodialysis session due to ultrafiltration. It is concluded that both hypoxia and hypoxaemia do occur during bicarbonate haemodialysis. To a group of patients generally having limited cardiac...... reserves, a poor oxygen status is a potentially serious complication to haemodialysis. Monitoring oxygen status is thus advisable....

  5. NOx emissions from high swirl turbulent spray flames with highly oxygenated fuels

    KAUST Repository

    Bohon, Myles

    2013-01-01

    Combustion of fuels with fuel bound oxygen is of interest from both a practical and a fundamental viewpoint. While a great deal of work has been done studying the effect of oxygenated additives in diesel and gasoline engines, much less has been done examining combustion characteristics of fuels with extremely high mass fractions of fuel bound oxygen. This work presents an initial investigation into the very low NOx emissions resulting from the combustion of a model, high oxygen mass fraction fuel. Glycerol was chosen as a model fuel with a fuel bound oxygen mass fraction of 52%, and was compared with emissions measured from diesel combustion at similar conditions in a high swirl turbulent spray flame. This work has shown that high fuel bound oxygen mass fractions allow for combustion at low global equivalence ratios with comparable exhaust gas temperatures due to the significantly lower concentrations of diluting nitrogen. Despite similar exhaust gas temperatures, NOx emissions from glycerol combustion were up to an order of magnitude lower than those measured using diesel fuel. This is shown to be a result not of specific burner geometry, but rather is influenced by the presence of higher oxygen and lower nitrogen concentrations at the flame front inhibiting NOx production. © 2012 The Combustion Institute.

  6. Effect of epidural blockade and oxygen therapy on changes in subcutaneous oxygen tension after abdominal surgery

    DEFF Research Database (Denmark)

    Rosenberg, J; Pedersen, U; Erichsen, C J

    1994-01-01

    The effect of oxygen therapy (37% by face mask) and epidural local anesthetic blockade (9 ml 0.5% bupivacaine at Th9-11 level) on wound oxygenation was evaluated in eight otherwise healthy patients undergoing elective colorectal resection. The patients were monitored continuously for subcutaneous...... without epidural blockade and 15 (10-20) min with blockade (P surgery....

  7. High-tension electrical injury to the heart as assessed by radionuclide imaging

    Energy Technology Data Exchange (ETDEWEB)

    Iino, Hitoshi; Chikamori, Taishiro; Hatano, Tsuguhisa [Tokyo Medical Coll. (Japan)] [and others

    2002-12-01

    The purpose of this study was to evaluate cardiac complications associated with electrical injury, 7 patients with high-tension electrical injury (6,600 V alternating current) underwent {sup 201}Tl and {sup 123}I-metaiodobenzylguanidine (MIBG) imaging in addition to conventional electrocardiographic and echocardiographic assessments. Electrocardiography showed transient atrial fibrillation, second degree atrioventricular block, ST-segment depression, and sinus bradycardia in each patient. Echocardiography showed mild hypokinesis of the anterior wall in only 2 patients, but {sup 201}Tl and {sup 123}I-MIBG myocardial scintigraphy showed an abnormal scan image in 6/7 and 5/6 patients, respectively. Decreased radionuclide accumulation was seen primarily in areas extending from the anterior wall to the septum. Decreased radionuclide accumulation was smaller in extent and milder in degree in {sup 123}I-MIBG than in {sup 201}Tl imaging. These results suggest that even in patients without definite evidence of severe cardiac complications in conventional examinations, radionuclide imaging detects significant damage due to high-tension electrical injury, in which sympathetic nerve dysfunction might be milder than myocardial cell damage. (author)

  8. Single-Step Fabrication of High-Density Microdroplet Arrays of Low-Surface-Tension Liquids.

    Science.gov (United States)

    Feng, Wenqian; Li, Linxian; Du, Xin; Welle, Alexander; Levkin, Pavel A

    2016-04-01

    A facile approach for surface patterning that enables single-step fabrication of high-density arrays of low-surface-tension organic-liquid microdroplets is described. This approach enables miniaturized and parallel high-throughput screenings in organic solvents, formation of homogeneous arrays of hydrophobic nanoparticles, polymer micropads of specific shapes, and polymer microlens arrays. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Tension Headache

    Science.gov (United States)

    ... tight band around your head. A tension headache (tension-type headache) is the most common type of headache, and ... Headache after a head injury, especially if the headache gets worse ... tension or stress. But research suggests muscle contraction isn't the ...

  10. Are macroinvertebrates in high altitude streams affected by oxygen deficiency?

    DEFF Research Database (Denmark)

    Jacobsen, Dean; Rostgaard, S.; Vásconez, J. J.

    2003-01-01

    1. The solubility of oxygen in water increases with decreasing temperature. This has led to a general perception of cold, high mountain streams as more oxygen rich than warmer lowland streams, and that macroinvertebrates inhabiting high altitude streams have had no need to adapt to critical oxygen...... conditions. However, this fails to take into account that oxygen solubility declines with decreasing atmospheric pressure, which may be of importance at high altitudes. 2. Based on samples of macroinvertebrate benthos and in situ measurements of respiratory oxygen demand of macroinvertebrates in small...... the mean weight-specific respiratory rate of macroinvertebrates declined by only 50%, from 400 to 3800 m. We suggest that this disproportionately large gap between availability and demand of oxygen at high altitudes may imply a potential oxygen deficiency for the fauna, and we discuss how oxygen deficiency...

  11. Spontaneous calcium waves in Bergman glia increase with age and hypoxia and may reduce tissue oxygen.

    Science.gov (United States)

    Mathiesen, Claus; Brazhe, Alexey; Thomsen, Kirsten; Lauritzen, Martin

    2013-02-01

    Glial calcium (Ca(2+)) waves constitute a means to spread signals between glial cells and to neighboring neurons and blood vessels. These waves occur spontaneously in Bergmann glia (BG) of the mouse cerebellar cortex in vivo. Here, we tested three hypotheses: (1) aging and reduced blood oxygen saturation alters wave activity; (2) glial Ca(2+) waves change cerebral oxygen metabolism; and (3) neuronal and glial wave activity is correlated. We used two-photon microscopy in the cerebellar cortexes of adult (8- to 15-week-old) and aging (48- to 80-week-old) ketamine-anesthetized mice after bolus loading with OGB-1/AM and SR101. We report that the occurrence of spontaneous waves is 20 times more frequent in the cerebellar cortex of aging as compared with adult mice, which correlated with a reduction in resting brain oxygen tension. In adult mice, spontaneous glial wave activity increased on reducing resting brain oxygen tension, and ATP-evoked glial waves reduced the tissue O(2) tension. Finally, although spontaneous Purkinje cell (PC) activity was not associated with increased glia wave activity, spontaneous glial waves did affect intracellular Ca(2+) activity in PCs. The increased wave activity during aging, as well as low resting brain oxygen tension, suggests a relationship between glial waves, brain energy homeostasis, and pathology.

  12. Sitting and standing postures are corrected by adjustable furniture with lowered muscle tension in high-school students.

    Science.gov (United States)

    Koskelo, R; Vuorikari, K; Hänninen, O

    2007-10-01

    This study compared the effect of 24 months of adjustable school desks and chairs usage (the intervention) and traditional non-adjustable usage (the control condition) on sitting and standing postures, muscle strength, classroom muscle tension, pain and learning in 15 (8 female and 7 male) high-school students and 15 anthropometrically and gender matched control students from neighbouring schools. It was assessed whether any responses took place after growth cessation. In comparison with controls, the intervention group of students' sitting postures standing kyphosis, scoliosis and lordosis became significantly better, both before and after growth cessation. Trunk muscle strength increased in the intervention students whose muscle tension during classes fell significantly in the trapezius and lumbar muscles, whereas in control students' lumbar tension increased. Headache and low-back pain correlated with neck-shoulder pain and trapezius muscle tension. Intervention students reported that they experienced benefits from the adjustable tables and chairs. They also received significantly better overall marks than the controls at the end of high school. It is concluded that the adjustable school desks and chairs promoted better sitting and standing postures, increased muscle strength, alleviated pain and appeared to be associated with better overall academic marks.

  13. Changes in the metabolic footprint of placental explant-conditioned medium cultured in different oxygen tensions from placentas of small for gestational age and normal pregnancies.

    LENUS (Irish Health Repository)

    Horgan, R P

    2012-01-31

    Being born small for gestational age (SGA) confers significantly increased risks of perinatal morbidity and mortality. Accumulating evidence suggests that an SGA fetus results from a poorly perfused and abnormally developed placenta. Some of the placental features seen in SGA, such as abnormal cell turnover and impaired nutrient transport, can be reproduced by culture of placental explants in hypoxic conditions. Metabolic footprinting offers a hypothesis-generating strategy to investigate factors absorbed by and released from this tissue in vitro. Previously, metabolic footprinting of the conditioned culture media has identified differences in placental explants cultured under normoxic and hypoxic conditions and between normal pregnancies and those complicated by pre-eclampsia. In this study we aimed to examine the differences in the metabolic footprint of placental villous explants cultured at different oxygen (O(2)) tensions between women who deliver an SGA baby (n = 9) and those from normal controls (n = 8). Placental villous explants from cases and controls were cultured for 96 h in 1% (hypoxic), 6% (normoxic) and 20% (hyperoxic) O(2). Metabolic footprints were analysed by Ultra Performance Liquid Chromatography coupled to an electrospray hybrid LTQ-Orbitrap Mass Spectrometry (UPLC-MS). 574 metabolite features showed significant difference between SGA and normal at one or more of the oxygen tensions. SGA explant media cultured under hypoxic conditions was observed, on a univariate level, to exhibit the same metabolic signature as controls cultured under normoxic conditions in 49% of the metabolites of interest, suggesting that SGA tissue is acclimatised to hypoxic conditions in vivo. No such behaviour was observed under hyperoxic culture conditions. Glycerophospholipid and tryptophan metabolism were highlighted as areas of particular interest.

  14. Temperature and oxygenation during organ preservation: friends or foes?

    Science.gov (United States)

    Gilbo, Nicholas; Monbaliu, Diethard

    2017-06-01

    The liberalization of donor selection criteria in organ transplantation, with the increased use of suboptimal grafts, has stimulated interest in ischemia-reperfusion injury prevention and graft reconditioning. Organ preservation technologies are changing considerably, mostly through the reintroduction of dynamic machine preservation. Here, we review the current evidence on the role of temperature and oxygenation during dynamic machine preservation. A large but complex body of evidence exists and comparative studies are few. Oxygenation seems to support an advantageous effect in hypothermic machine preservation and is mandatory in normothermic machine preservation, although in the latter, supraphysiological oxygen tensions should be avoided. High-risk grafts, such as suboptimal organs, may optimally benefit from oxygenated perfusion conditions that support metabolism and activate mechanisms of repair such as subnormothermic machine preservation, controlled oxygenated rewarming, and normothermic machine preservation. For lower risk grafts, oxygenation during hypothermic machine preservation may sufficiently reduce injuries and recharge the cellular energy to secure functional recovery after transplantation. The relationship between temperature and oxygenation in organ preservation is more complex than physiological laws would suggest. Rather than one default perfusion temperature/oxygenation standard, perfusion protocols should be tailored for specific needs of grafts of different quality.

  15. Radiosensitivity of Hela cells in various O2 concentrations and consideration of oxygen effect in radiotherapy

    International Nuclear Information System (INIS)

    Kuroda, Yoshikazu; Nyunoya, Koichiro

    1979-01-01

    The aim of this paper is the study of the radiosensitivity of HeLa cells in vitro in various oxygen concentrations and the consideration of the utilization of oxygen effect in radiation therapy, based on the data of HeLa cells and tumor oxygen tension. Survival curves of HeLa cells are found to be exponential as a function of radiation dose and the radiosensitivity is dependent on oxygen tension of culture medium. Relative radiosensitivity decreases remarkably at low level of oxygen, especially under 9 mmHg pO 2 . The utilization of oxygen effect in radiation may be useful in hyperbaric oxygen inhalation and not useful under local tissue hypoxia induced by tourniquet application. Reoxygenation occurs with shrinkage of tumor after irradiation and this phenomenon will diminish the value of hyperbaric oxygen in radiation therapy. (author)

  16. Initial tension loss in cerclage cables.

    Science.gov (United States)

    Ménard, Jérémie; Émard, Maxime; Canet, Fanny; Brailovski, Vladimir; Petit, Yvan; Laflamme, George Y

    2013-10-01

    Cerclage cables, frequently used in the management of fractures and osteotomies, are associated with a high failure rate and significant loosening during surgery. This study compared the capacity to maintain tension of different types of orthopaedic cable systems. Multifilament Cobalt-Chrome (CoCr) cables with four different crimp/clamp devices (DePuy, Stryker, Zimmer and Smith&Nephew) and one non-metallic Nylon (Ny) cable from Kinamed were instrumented with a load cell to measure tension during insertion. Significant tension loss was observed with crimping for all cables (Ptensioner led to an additional unexpected tension loss (CoCr-DePuy: 18%, CoCr-Stryker: 29%, CoCr-Smith&Nephew: 33%, Ny: 46%, and CoCr-Zimmer: 52%). The simple CoCr (DePuy) cable system outperformed the more sophisticated locking devices due to its significantly better ability to prevent tension loss. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. The concentration of oxygen dissolved in tissues at the time of irradiation as a factor in radiotherapy

    International Nuclear Information System (INIS)

    Gray, L.H.; Conger, A.D.; Ebert, M.; Hornsey, S.; Scott, O.C.A.

    1984-01-01

    The sensitivity of tumour cells to X rays has been shown to be about three times as great when irradiated in a well-oxygenated medium as under anoxic conditions. The manner in which sensitivity depends on oxygen tension closely resembles that found by other workers for plant and insect tissues. The sensitivity of the tumour cells to fast neutron radiation is only slightly affected by oxygen tension. Consideration is given to the supply of oxygen to tissues as a factor in radiotherapy, and it is concluded on the basis of existing knowledge that in certain circumstances the effectiveness of X-ray treatment might be increased if the patient were breathing oxygen at the time of irradiation

  18. Oxygen Handling and Cooling Options in High Temperature Electrolysis Plants

    Energy Technology Data Exchange (ETDEWEB)

    Manohar S. Sohal; J. Stephen Herring

    2008-07-01

    Idaho National Laboratory is working on a project to generate hydrogen by high temperature electrolysis (HTE). In such an HTE system, safety precautions need to be taken to handle high temperature oxygen at ~830°C. This report is aimed at addressing oxygen handling in a HTE plant.. Though oxygen itself is not flammable, most engineering material, including many gases and liquids, will burn in the presence of oxygen under some favorable physicochemical conditions. At present, an absolute set of rules does not exist that can cover all aspects of oxygen system design, material selection, and operating practices to avoid subtle hazards related to oxygen. Because most materials, including metals, will burn in an oxygen-enriched environment, hazards are always present when using oxygen. Most materials will ignite in an oxygen-enriched environment at a temperature lower than that in air, and once ignited, combustion rates are greater in the oxygen-enriched environment. Even many metals, if ignited, burn violently in an oxygen-enriched environment. However, these hazards do not preclude the operations and systems involving oxygen. Oxygen can be safely handled and used if all the materials in a system are not flammable in the end-use environment or if ignition sources are identified and controlled. In fact, the incidence of oxygen system fires is reported to be low with a probability of about one in a million. This report is a practical guideline and tutorial for the safe operation and handling of gaseous oxygen in high temperature electrolysis system. The intent is to provide safe, practical guidance that permits the accomplishment of experimental operations at INL, while being restrictive enough to prevent personnel endangerment and to provide reasonable facility protection. Adequate guidelines are provided to govern various aspects of oxygen handling associated with high temperature electrolysis system to generate hydrogen. The intent here is to present acceptable

  19. Tension waves in tethered satellite cables

    Science.gov (United States)

    Lallman, F. J.

    1984-01-01

    A one-degree-of-freedom simulation of the Tethered Satellite System (TSS) was programmed using a distributed system model of the tether based on the one-dimensional wave equation. This model represents the time varying tension profile along the tether as the sum of two traveling waves of tension moving in opposite directions. A control loop was devised which combines a deployment rate command with the measured tension at the deployer to produce a smooth, stable rate of deployment of the subsatellite. Simulation results show a buildup of periodic bursts of high frequency oscillation in tension. This report covers the mathematical modelling and simulation results and explains the reason for the observed oscillations. The design of a possible vibration damping device is discussed.

  20. The study and design of tension controller

    Science.gov (United States)

    Jun, G.; Lamei, X.

    2018-02-01

    Tension control is a wide used technology in areas such as textiles, paper and plastic films. In this article, the tension control system release and winding process is analyzed and the mathematical model of tension control system is established, and a high performance tension controller is designed. In hardware design, STM32F130 single chip microcomputer is used as the control core, which has the characteristics of fast running speed and rich peripheral features. In software design, μC/OS-II operating system is introduced to improve the efficiency of single chip microcomputer, and enhance the independence of each module, and make development and maintenance more convenient. The taper tension control is adopted in the winding part, which can effectively solve the problem of rolling shrinkage. The results show that the tension controller has the characteristics of simple structure, easy operation and stable performance.

  1. Increase of tumor oxygen tension and potentiation of radiation effects using pentoxifylline, vinpocetine and ticlopidine hydrochloride

    International Nuclear Information System (INIS)

    Amano, Morikazu; Monzen, Hajime; Suzuki, Takatoshi; Hasegawa, Takeo

    2004-01-01

    The effects of pentoxifylline (PTX), vinpocetine (VPT) and ticlopidine hydrochloride (TCD), each drug commonly used for vascular disorders in humans, on the pO 2 in SCC-7 (squamous cell carcinoma) tumors of C3H/HeJ mice on the radioresponse of SCC-7 tumors were investigated. When the SCC-7 implanted in the leg of C3H/HeJ mice grew about 100 mm 3 , the effects of PTX, VPT and TCD on the increase oxygen tension in the tumor was determined with polarography. The mice were injected intraperitoneally (ip) with 5 ml/kg PTX, 5 ml/kg VPT, or 10 ml/kg TCD, the tumor pO 2 increased slowly, peaked about 20-50 min postinjection, and returned to its original level in 60-80 min. When the C3H/HeJ mice bearing SCC-7 tumors in the legs were injected ip with 5 ml/kg PTX, 5 ml/kg VPT or 10 ml/kg TCD and tumors were X-irradiated 30 min later, the radiation induced growth delay of the tumor was greater than that caused by X-irradiation alone. The results in the present study, PTX, VPT and TCD increase the tumor pO 2 in rodent tumors strongly suggest that each drug may be useful for increasing the radiosensitivity of human tumor. (author)

  2. Faraday forcing of high-temperature levitated liquid metal drops for the measurement of surface tension.

    Science.gov (United States)

    Brosius, Nevin; Ward, Kevin; Matsumoto, Satoshi; SanSoucie, Michael; Narayanan, Ranga

    2018-01-01

    In this work, a method for the measurement of surface tension using continuous periodic forcing is presented. To reduce gravitational effects, samples are electrostatically levitated prior to forcing. The method, called Faraday forcing, is particularly well suited for fluids that require high temperature measurements such as liquid metals where conventional surface tension measurement methods are not possible. It offers distinct advantages over the conventional pulse-decay analysis method when the sample viscosity is high or the levitation feedback control system is noisy. In the current method, levitated drops are continuously translated about a mean position at a small, constant forcing amplitude over a range of frequencies. At a particular frequency in this range, the drop suddenly enters a state of resonance, which is confirmed by large executions of prolate/oblate deformations about the mean spherical shape. The arrival at this resonant condition is a signature that the parametric forcing frequency is equal to the drop's natural frequency, the latter being a known function of surface tension. A description of the experimental procedure is presented. A proof of concept is given using pure Zr and a Ti 39.5 Zr 39.5 Ni 21 alloy as examples. The results compare favorably with accepted literature values obtained using the pulse-decay method.

  3. High oxygen levels promote peel spotting in banana fruit

    NARCIS (Netherlands)

    Maneenuam, T.; Ketsa, S.; Doorn, van W.G.

    2007-01-01

    We studied the effect of high oxygen on early peel spotting in `Sucrier¿ bananas held at 25 °C and 90% RH. Fruit first ripened to colour index 3¿4 (about as yellow as green) and were then held in containers with a continuous gas flow of 18 ± 2 kPa (control) or 90 ± 2 kPa oxygen. High oxygen promoted

  4. Coulomb string tension, asymptotic string tension, and the gluon chain

    OpenAIRE

    Greensite, Jeff; Szczepaniak, Adam P.

    2014-01-01

    We compute, via numerical simulations, the non-perturbative Coulomb potential of pure SU(3) gauge theory in Coulomb gauge. We find that that the Coulomb potential scales nicely in accordance with asymptotic freedom, that the Coulomb potential is linear in the infrared, and that the Coulomb string tension is about four times larger than the asymptotic string tension. We explain how it is possible that the asymptotic string tension can be lower than the Coulomb string tension by a factor of four.

  5. Behaviour of high stretch bolts in tension working as part of elements of steel structures, and their tendency to delayed fracturing

    Directory of Open Access Journals (Sweden)

    Moyseychik Evgeniy Alekseevich

    2014-12-01

    Full Text Available In the article, the author has proven that manufacturing and installation errors, as well as contact deformations of high strength bolts, if analyzed as part of tensile connections of steel structures, work in eccentric tension. In pursuance of the effective state standards, the analysis of these bolts is based on the axial tension. The author has analyzed the failure of a steel structure, caused by the fracture of eccentrically loaded bolts made of steel grade XC 42 (France, or C40 (Germany, that later followed the delayed fracturing pattern. The author provides the findings of the lab tests, whereby the above bolts were tested in the presence of an angle washer. The author has also analyzed the findings of low-temperature tests of bolts in tension. The author demonstrates that the strength of high strength bolts is driven by the material, the structure shape, and the thermal treatment pattern. Eccentric tension tests of bolts have proven that cracks emerge in the areas of maximal concentration of stresses (holes in shafts, etc. that coincide with the areas where fibers are in tension; cracks tend to follow the delayed fracturing pattern, and their development is accompanied by the deformation-induced metal heating in the fracture area. Therefore, the analysis of high strength bolts shall concentrate on the eccentric tension with account for contact-induced loads, while the tendency to delayed fracturing may be adjusted through the employment of both metallurgical and process techniques.

  6. Tensions in the meeting between institutional logics and identities in Swedish folk high schools

    OpenAIRE

    Runesdotter, Caroline

    2011-01-01

    Swedish folk high schools previously held an autonomous position with their own courses, specially trained teachers and the teachers’ association. With the introduction of market-like structures in adult education a variety of providers including folk high schools have become involved in the competition for public and private educational commissions. This article focuses on the tensions at folk high schools when perceived dependence on income from competitive commissions results in new practi...

  7. Dynamic high-temperature characterization of an iridium alloy in tension

    Energy Technology Data Exchange (ETDEWEB)

    Song, Bo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Nelson, Kevin [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Jin, Helena [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Lipinski, Ronald J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bignell, John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ulrich, G. B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); George, E. P. [Ruhr Univ., Bochum (Germany)

    2015-09-01

    Iridium alloys have been utilized as structural materials for certain high-temperature applications, due to their superior strength and ductility at elevated temperatures. The mechanical properties, including failure response at high strain rates and elevated temperatures of the iridium alloys need to be characterized to better understand high-speed impacts at elevated temperatures. A DOP-26 iridium alloy has been dynamically characterized in compression at elevated temperatures with high-temperature Kolsky compression bar techniques. However, the dynamic high-temperature compression tests were not able to provide sufficient dynamic high-temperature failure information of the iridium alloy. In this study, we modified current room-temperature Kolsky tension bar techniques for obtaining dynamic tensile stress-strain curves of the DOP-26 iridium alloy at two different strain rates (~1000 and ~3000 s-1) and temperatures (~750°C and ~1030°C). The effects of strain rate and temperature on the tensile stress-strain response of the iridium alloy were determined. The DOP-26 iridium alloy exhibited high ductility in stress-strain response that strongly depended on both strain rate and temperature.

  8. Nitric oxide formation from the reaction of nitrite with carp and rabbit hemoglobin at intermediate oxygen saturations

    DEFF Research Database (Denmark)

    Jensen, Frank Bo

    2008-01-01

    The nitrite reductase activity of deoxyhemoglobin has received much recent interest because the nitric oxide produced in this reaction may participate in blood flow regulation during hypoxia. The present study used spectral deconvolution to characterize the reaction of nitrite with carp and rabbit...... hemoglobin at different constant oxygen tensions that generate the full range of physiological relevant oxygen saturations. Carp is a hypoxia-tolerant species with very high hemoglobin oxygen affinity, and the high R-state character and low redox potential of the hemoglobin is hypothesized to promote...... NO generation from nitrite. The reaction of nitrite with deoxyhemoglobin leads to a 1 : 1 formation of nitrosylhemoglobin and methemoglobin in both species. At intermediate oxygen saturations, the reaction with deoxyhemoglobin is clearly favored over that with oxyhemoglobin, and the oxyhemoglobin reaction...

  9. Oxygen dynamics around buried lesser sandeels Ammodytes tobianus (Linnaeus 1785): mode of ventilation and oxygen requirements

    DEFF Research Database (Denmark)

    Behrens, Jane W; Stahl, Henrik J; Steffensen, John F

    2007-01-01

    The oxygen environment around buried sandeels (Ammodytes tobianus) was monitored by planar optodes. The oxygen penetration depth at the sediment interface was only a few mm. Thus fish, typically buried at 1-4 cm depth, were generally in anoxic sediment. However, they induced an advective transport...... down along the body, referred to as ;plume ventilation'. Yet, within approximately 30 min the oxic plume was replenished by oxygen-depleted water from the gills. The potential for cutaneous respiration by the buried fish was thus of no quantitative importance. Calculations derived by three independent...... methods (each with N=3) revealed that the oxygen uptake of sandeel buried for 6-7 h was 40-50% of previous estimates on resting respirometry of non-buried fish, indicating lower O(2) requirements during burial on a diurnal timescale. Buried fish exposed to decreasing oxygen tensions gradually approached...

  10. Ion release from magnesium materials in physiological solutions under different oxygen tensions.

    Science.gov (United States)

    Feyerabend, Frank; Drücker, Heiko; Laipple, Daniel; Vogt, Carla; Stekker, Michael; Hort, Norbert; Willumeit, Regine

    2012-01-01

    Although magnesium as degradable biomaterial already showed clinical proof of concepts, the design of new alloys requires predictive in vitro methods, which are still lacking. Incubation under cell culture conditions to obtain "physiological" corrosion may be a solution. The aim of this study was to analyse the influence of different solutions, addition of proteins and of oxygen availability on the corrosion of different magnesium materials (pure Mg, WE43, and E11) with different surface finishing. Oxygen content in solution, pH, osmolality and ion release were determined. Corrosion led to a reduction of oxygen in solution. The influence of oxygen on pH was enhanced by proteins, while osmolality was not influenced. Magnesium ion release was solution-dependent and enhanced in the initial phase by proteins with delayed release of alloying elements. The main corrosion product formed was magnesium carbonate. Therefore, cell culture conditions are proposed as first step toward physiological corrosion.

  11. Reduced muscle activation during exercise related to brain oxygenation and metabolism in humans

    DEFF Research Database (Denmark)

    Rasmussen, Peter; Nielsen, Jannie; Overgaard, M

    2010-01-01

    Maximal exercise may be limited by central fatigue defined as an inability of the central nervous system to fully recruit the involved muscles. This study evaluated whether a reduction in the cerebral oxygen-to-carbohydrate index (OCI) and in the cerebral mitochondrial oxygen tension relate to th...... indicating that reduced cerebral oxygenation may play a role in the development of central fatigue and may be an exercise capacity limiting factor.......Maximal exercise may be limited by central fatigue defined as an inability of the central nervous system to fully recruit the involved muscles. This study evaluated whether a reduction in the cerebral oxygen-to-carbohydrate index (OCI) and in the cerebral mitochondrial oxygen tension relate...... of perceived exertion (RPE), arm maximal voluntary force (MVC), and voluntary activation of elbow flexor muscles assessed with transcranial magnetic stimulation. Low intensity exercise did not produce any indication of central fatigue or marked cerebral metabolic deviations. Exercise in hypoxia (0.10) reduced...

  12. Macrophages Under Low Oxygen Culture Conditions Respond to Ion Parametric Resonance Magnetic Fields

    Science.gov (United States)

    Macrophages, when entering inflamed tissue, encounter low oxygen tension due to the impairment of blood supply and/or the massive infiltration of cells that consume oxygen. Previously, we showed that such macrophages release more bacteriotoxic hydrogen peroxide (H202) when expose...

  13. Effects of Changes in Arterial Carbon Dioxide and Oxygen Partial Pressures on Cerebral Oximeter Performance.

    Science.gov (United States)

    Schober, Andrew; Feiner, John R; Bickler, Philip E; Rollins, Mark D

    2018-01-01

    Cerebral oximetry (cerebral oxygen saturation; ScO2) is used to noninvasively monitor cerebral oxygenation. ScO2 readings are based on the fraction of reduced and oxidized hemoglobin as an indirect estimate of brain tissue oxygenation and assume a static ratio of arterial to venous intracranial blood. Conditions that alter cerebral blood flow, such as acute changes in PaCO2, may decrease accuracy. We assessed the performance of two commercial cerebral oximeters across a range of oxygen concentrations during normocapnia and hypocapnia. Casmed FORE-SIGHT Elite (CAS Medical Systems, Inc., USA) and Covidien INVOS 5100C (Covidien, USA) oximeter sensors were placed on 12 healthy volunteers. The fractional inspired oxygen tension was varied to achieve seven steady-state levels including hypoxic and hyperoxic PaO2 values. ScO2 and simultaneous arterial and jugular venous blood gas measurements were obtained with both normocapnia and hypocapnia. Oximeter bias was calculated as the difference between the ScO2 and reference saturation using manufacturer-specified weighting ratios from the arterial and venous samples. FORE-SIGHT Elite bias was greater during hypocapnia as compared with normocapnia (4 ± 9% vs. 0 ± 6%; P oxygen saturation and mixed venous oxygen tension, as well as increased oxygen extraction across fractional inspired oxygen tension levels (P oxygen extraction (P < 0.0001). Changes in PaCO2 affect cerebral oximeter accuracy, and increased bias occurs with hypocapnia. Decreased accuracy may represent an incorrect assumption of a static arterial-venous blood fraction. Understanding cerebral oximetry limitations is especially important in patients at risk for hypoxia-induced brain injury, where PaCO2 may be purposefully altered.

  14. The tension of framed membranes from computer simulations

    DEFF Research Database (Denmark)

    Hamkens, Daniel; Jeppesen, Claus; Ipsen, John H.

    2018-01-01

    the membranes display power-law characteristics for the equation of state, while higher tension levels includes both an extended linear (elastic) as well as a highly non-linear stretching regime. For semi-flexible membranes a transition from extended to buckled conformations takes place at negative frame......Abstract.: We have analyzed the behavior of a randomly triangulated, self-avoiding surface model of a flexible, fluid membrane subject to a circular boundary by Wang-Landau Monte Carlo computer simulation techniques. The dependence of the canonical free energy and frame tension on the frame area...... is obtained for flexible membranes. It is shown that for low bending rigidities the framed membrane is only stable above a threshold tension, suggesting a discontinuous transition from the collapsed (branched polymer) state to a finite tension extended state. In a tension range above this threshold tension...

  15. Necessary Tension in Marine Risers Tension des colonnes montantes en mer

    Directory of Open Access Journals (Sweden)

    Lubinski A.

    2006-11-01

    Full Text Available The tension governing transverse static and dynamic deflections in a riser is not the actual tension but the so-called « effective tension » The concept of effective tension and effective compression is thoroughly explained, and means for calculating effective forces are given. Numerical examples are worked out for risers whose length is between 152 m (520 ft and 920 m (3020 ft. The reciprocal of maximum bending moment of the vicinity of the hall joint is plotted versus the effective tension of the ball joint. Bending moments used were obtained through use of static and dynamic computer programs applied ta a variety of conditions of wave loading, use or non-use of buoyant moterial sleeves, etc. The most important parameters affecting riser performance are the effective La tension régissant les déflections transversales statiques et dynamiques d'une colonne montante n'est pas la tension réelle mais ce qu'on appelle « la tension effective ». Le concept de tension ou de compression effective est expliqué en détail et la façon de calculer les forces effectives est indiquée dans cet article. Des exemples numériques sont développés pour des colonnes montantes de longueur comprise entre 152 m (520 ft et 920 m (3 020 ft. On a tracé la courbe de l'inverse du moment fléchissant en fonction de la tension effective à l'articulation. Les moments fléchissants utilisés ont été calculés par ordinateur en utilisant des programmes dynamiques et statiques pour des conditions variées d'action des vagues, la colonne montante étant ou non munie de manchettes de flottabilité, etc. Les deux paramètres les plus importants qui affectent le bon comportement d'une colonne montante sont la tension effective et la charge latérale.

  16. A hybrid multibreath wash-in wash-out lung function quantification scheme in human subjects using hyperpolarized 3 He MRI for simultaneous assessment of specific ventilation, alveolar oxygen tension, oxygen uptake, and air trapping.

    Science.gov (United States)

    Hamedani, Hooman; Kadlecek, Stephen; Xin, Yi; Siddiqui, Sarmad; Gatens, Heather; Naji, Joseph; Ishii, Masaru; Cereda, Maurizio; Rossman, Milton; Rizi, Rahim

    2017-08-01

    To present a method for simultaneous acquisition of alveolar oxygen tension (P A O 2 ), specific ventilation (SV), and apparent diffusion coefficient (ADC) of hyperpolarized (HP) gas in the human lung, allowing reinterpretation of the P A O 2 and SV maps to produce a map of oxygen uptake (R). An imaging scheme was designed with a series of identical normoxic HP gas wash-in breaths to measure ADC, SV, P A O 2 , and R in less than 2 min. Signal dynamics were fit to an iterative recursive model that regionally solved for these parameters. This measurement was successfully performed in 12 subjects classified in three healthy, smoker, and chronic obstructive pulmonary disease (COPD) cohorts. The overall whole lung ADC, SV, P A O 2 , and R in healthy, smoker, and COPD subjects was 0.20 ± 0.03 cm 2 /s, 0.39 ± 0.06,113 ± 2 Torr, and 1.55 ± 0.35 Torr/s, respectively, in healthy subjects; 0.21 ± 0.03 cm 2 /s, 0.33 ± 0.06, 115.9 ± 4 Torr, and 0.97 ± 0.2 Torr/s, respectively, in smokers; and 0.25 ± 0.06 cm 2 /s, 0.23 ± 0.08, 114.8 ± 6.0Torr, and 0.94 ± 0.12 Torr/s, respectively, in subjects with COPD. Hetrogeneity of SV, P A O 2 , and R were indicators of both smoking-related changes and disease, and the severity of the disease correlated with the degree of this heterogeneity. Subjects with symptoms showed reduced oxygen uptake and specific ventilation. High-resolution, nearly coregistered and quantitative measures of lung function and structure were obtained with less than 1 L of HP gas. This hybrid multibreath technique produced measures of lung function that revealed clear differences among the cohorts and subjects and were confirmed by correlations with global lung measurements. Magn Reson Med 78:611-624, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  17. High oxygen as an additional factor in food preservation

    NARCIS (Netherlands)

    Amanatidou, A.

    2001-01-01

    In this thesis, the efficacy of high oxygen as an additional hurdle for food preservation is studied. At high oxygen conditions and at low temperature, significant impairment of growth and viability of bacterial cells is found to occur as the result of free

  18. Surface tension estimation of high temperature melts of the binary alloys Ag-Au

    Science.gov (United States)

    Dogan, Ali; Arslan, Hüseyin

    2017-11-01

    Surface tension calculation of the binary alloys Ag-Au at the temperature of 1381 K, where Ag and Au have similar electronic structures and their atomic radii are comparable, are carried out in this study using several equations over entire composition range of Au. Apparently, the deviations from ideality of the bulk solutions, such as activities of Ag and Au are small and the maximum excess Gibbs free energy of mixing of the liquid phase is for instance -4500 J/mol at XAu = 0.5. Besides, the results obtained in Ag-Au alloys that at a constant temperature the surface tension increases with increasing composition while the surface tension decreases as the temperature increases for entire composition range of Au. Although data about surface tension of the Ag-Au alloy are limited, it was possible to make a comparison for the calculated results for the surface tension in this study with the available experimental data. Taken together, the average standard error analysis that especially the improved Guggenheim model in the other models gives the best agreement along with the experimental results at temperature 1383 K although almost all models are mutually in agreement with the other one.

  19. Tension and robustness in multitasking cellular networks.

    Directory of Open Access Journals (Sweden)

    Jeffrey V Wong

    Full Text Available Cellular networks multitask by exhibiting distinct, context-dependent dynamics. However, network states (parameters that generate a particular dynamic are often sub-optimal for others, defining a source of "tension" between them. Though multitasking is pervasive, it is not clear where tension arises, what consequences it has, and how it is resolved. We developed a generic computational framework to examine the source and consequences of tension between pairs of dynamics exhibited by the well-studied RB-E2F switch regulating cell cycle entry. We found that tension arose from task-dependent shifts in parameters associated with network modules. Although parameter sets common to distinct dynamics did exist, tension reduced both their accessibility and resilience to perturbation, indicating a trade-off between "one-size-fits-all" solutions and robustness. With high tension, robustness can be preserved by dynamic shifting of modules, enabling the network to toggle between tasks, and by increasing network complexity, in this case by gene duplication. We propose that tension is a general constraint on the architecture and operation of multitasking biological networks. To this end, our work provides a framework to quantify the extent of tension between any network dynamics and how it affects network robustness. Such analysis would suggest new ways to interfere with network elements to elucidate the design principles of cellular networks.

  20. Membrane tension regulates clathrin-coated pit dynamics

    Science.gov (United States)

    Liu, Allen

    2014-03-01

    Intracellular organization depends on close communication between the extracellular environment and a network of cytoskeleton filaments. The interactions between cytoskeletal filaments and the plasma membrane lead to changes in membrane tension that in turns help regulate biological processes. Endocytosis is thought to be stimulated by low membrane tension and the removal of membrane increases membrane tension. While it is appreciated that the opposing effects of exocytosis and endocytosis have on keeping plasma membrane tension to a set point, it is not clear how membrane tension affects the dynamics of clathrin-coated pits (CCPs), the individual functional units of clathrin-mediated endocytosis. Furthermore, although it was recently shown that actin dynamics counteracts membrane tension during CCP formation, it is not clear what roles plasma membrane tension plays during CCP initiation. Based on the notion that plasma membrane tension is increased when the membrane area increases during cell spreading, we designed micro-patterned surfaces of different sizes to control the cell spreading sizes. Total internal reflection fluorescence microscopy of living cells and high content image analysis were used to quantify the dynamics of CCPs. We found that there is an increased proportion of CCPs with short (<20s) lifetime for cells on larger patterns. Interestingly, cells on larger patterns have higher CCP initiation density, an effect unexpected based on the conventional view of decreasing endocytosis with increasing membrane tension. Furthermore, by analyzing the intensity profiles of CCPs that were longer-lived, we found CCP intensity decreases with increasing cell size, indicating that the CCPs are smaller with increasing membrane tension. Finally, disruption of actin dynamics significantly increased the number of short-lived CCPs, but also decreased CCP initiation rate. Together, our study reveals new mechanistic insights into how plasma membrane tension regulates

  1. High-tension electricity network expansions in Argentina: decision mechanisms and willingness-to-pay revelation

    Energy Technology Data Exchange (ETDEWEB)

    Chisari, O.O. [Departamento de Economia y Finanzas, Universidad Argentina de la Empresa, Chile 1142 lo piso, 1073 Buenos Aires (Argentina); Dal-Bo, P. [Department of Economics, University of California, Los Angeles, CA (United States); Romero, C.A. [Departamento de Economia y Finanzas and Centro de Estudios Economicos de la Regulacion, Universidad Argentina de la Empresa, Buenos Aires (Argentina)

    2001-11-01

    This paper describes the procedures established by the present regulation for high-tension network expansions, studies its optimality and points its main problems. According to the present regulatory scheme, the decision to expand the high-tension network system is on the hands of the private sector. A simple model of the Argentine electricity system and its regulation allowed the simulation of cases in which the present 'Public Contest' method could result in the rejection of socially desirable projects and the acceptance of undesirable ones. Three main reasons for the existence of wrong incentives to investment are found. First, since consumers are not included in the mechanism, they have no way to reveal their willingness-to-pay for the investment. Second, the approximation of the future use of the line is done in such a way that it leaves important nodes under represented, thereby affecting the optimality of the mechanism. Third, the profit agents obtain from a line may not be related to their use, e.g. the generators profits depend also on generation costs.

  2. High-tension electricity network expansions in Argentina: decision mechanisms and willingness-to-pay revelation

    International Nuclear Information System (INIS)

    Chisari, O.O.; Dal-Bo, P.; Romero, C.A.

    2001-01-01

    This paper describes the procedures established by the present regulation for high-tension network expansions, studies its optimality and points its main problems. According to the present regulatory scheme, the decision to expand the high-tension network system is on the hands of the private sector. A simple model of the Argentine electricity system and its regulation allowed the simulation of cases in which the present 'Public Contest' method could result in the rejection of socially desirable projects and the acceptance of undesirable ones. Three main reasons for the existence of wrong incentives to investment are found. First, since consumers are not included in the mechanism, they have no way to reveal their willingness-to-pay for the investment. Second, the approximation of the future use of the line is done in such a way that it leaves important nodes under represented, thereby affecting the optimality of the mechanism. Third, the profit agents obtain from a line may not be related to their use, e.g. the generators profits depend also on generation costs

  3. Effects of Cyanate and 2,3-Diphosphoglycerate on Sickling RELATIONSHIP TO OXYGENATION

    Science.gov (United States)

    Jensen, Michael; Bunn, H. Franklin; Halikas, George; Kan, Yuet Wai; Nathan, David G.

    1973-01-01

    Cyanate and 2,3-diphosphoglycerate (2,3-DPG) both influence the oxygen affinity of hemoglobin. The studies presented here concern the effects of these compounds on the sickling phenomenon. The inhibitory effect of cyanate on sickling is largely due to the fact that it increases the percentage of oxyhemoglobin S at a given oxygen tension. In addition, cyanate inhibits sickling by a mechanism that is independent of oxygenation. In this paper, we have demonstrated that the viscosity of carbamylated sickle blood was lower than that of non-carbamylated controls at the same oxygen saturation. Furthermore, carbamylation resulted in an increase in the minimum concentration of deoxy-sickle hemoglobin required for gelation. Like cyanate, 2,3-DPG affected sickling of intact erythrocytes by two mechanisms. Since 2,3-DPG decreases the percentage of oxyhemoglobin S at a given oxygen tension, sickling is enhanced. In addition, 2,3-DPG had a direct effect. When the intracellular 2,3-DPG concentration was increased in vitro, a greater percentage of cells were sickled at a given oxygen saturation. Conversely, sickling was inhibited in cells in which 2,3-DPG was artificially lowered. These data indicate that the enhancement of sickling by 2,3-DPG is in part independent of its influence on oxygen affinity. PMID:4729047

  4. Optimal Cable Tension Distribution of the High-Speed Redundant Driven Camera Robots Considering Cable Sag and Inertia Effects

    Directory of Open Access Journals (Sweden)

    Yu Su

    2014-03-01

    Full Text Available Camera robots are high-speed redundantly cable-driven parallel manipulators that realize the aerial panoramic photographing. When long-span cables and high maneuverability are involved, the effects of cable sags and inertias on the dynamics must be carefully dealt with. This paper is devoted to the optimal cable tension distribution (OCTD for short of the camera robots. Firstly, each fast varying-length cable is discretized into some nodes for computing the cable inertias. Secondly, the dynamic equation integrated with the cable inertias is set up regarding the large-span cables as catenaries. Thirdly, an iterative optimization algorithm is introduced for the cable tension distribution by using the dynamic equation and sag-to-span ratios as constraint conditions. Finally, numerical examples are presented to demonstrate the effects of cable sags and inertias on determining tensions. The results justify the convergence and effectiveness of the algorithm. In addition, the results show that it is necessary to take the cable sags and inertias into consideration for the large-span manipulators.

  5. Job-related tension, self-esteem and psychological distress in rehabilitation professionals.

    Science.gov (United States)

    Flett, R; Biggs, H; Alpass, F

    1995-06-01

    We examined perceptions of job-related tension among a non-random sample of 52 New Zealand rehabilitation service providers. We considered the relations between job tension and psychological distress and the extent to which feelings of self-esteem moderated this relationship. Major findings are that (a) there is a consistent positive relationship between job tension and general psychological distress; (b) there is a consistent negative relationship between self-esteem and both job tension and general distress; (c) self-esteem moderates the effect of job tension on general distress in that high levels of job tension were associated with increases in psychological distress among respondents with low self-esteem while among respondents with high-self esteem, job-related tension had little negative impact on feelings of psychological distress. Despite a number of limitations, the findings have a number of important implications for professional functioning among rehabilitation service providers and highlight the need for appropriate staff development and training initiatives which focus specifically on service provider wellbeing.

  6. Optimal oxygen saturation in premature infants

    Directory of Open Access Journals (Sweden)

    Meayoung Chang

    2011-09-01

    Full Text Available There is a delicate balance between too little and too much supplemental oxygen exposure in premature infants. Since underuse and overuse of supplemental oxygen can harm premature infants, oxygen saturation levels must be monitored and kept at less than 95% to prevent reactive oxygen species-related diseases, such as retinopathy of prematurity and bronchopulmonary dysplasia. At the same time, desaturation below 80 to 85% must be avoided to prevent adverse consequences, such as cerebral palsy. It is still unclear what range of oxygen saturation is appropriate for premature infants; however, until the results of further studies are available, a reasonable target for pulse oxygen saturation (SpO2 is 90 to 93% with an intermittent review of the correlation between SpO2 and the partial pressure of arterial oxygen tension (PaO2. Because optimal oxygenation depends on individuals at the bedside making ongoing adjustments, each unit must define an optimal target range and set alarm limits according to their own equipment or conditions. All staff must be aware of these values and adjust the concentration of supplemental oxygen frequently.

  7. Gastrothorax or tension pneumothorax: A diagnostic dilemma

    Directory of Open Access Journals (Sweden)

    Singh Sarvesh

    2011-01-01

    Full Text Available Gastrothorax, a rare complication following thoracoabdominal aortic aneurysm repair, is reported. The clinical features of a gastrothorax and tension pneumothorax are similar and thus, a gastrothorax can masquerade as a tension pneumothorax. The diagnosis is made by a high level of clinical suspicion, chest X-ray shows a distended stomach with air fluid levels and a computerised tomography is useful in assessing the diaphragm and establishing the positions of the various intra-abdominal organs. Also, the risk of an intercostal drainage tube placement and the role of nasogastric tube in avoiding the development of a tension gastrothorax is highlighted.

  8. Tension Band Plating for Chronic Anterior Tibial Stress Fractures in High-Performance Athletes.

    Science.gov (United States)

    Zbeda, Robert M; Sculco, Peter K; Urch, Ekaterina Y; Lazaro, Lionel E; Borens, Olivier; Williams, Riley J; Lorich, Dean G; Wellman, David S; Helfet, David L

    2015-07-01

    Anterior tibial stress fractures are associated with high rates of delayed union and nonunion, which can be particularly devastating to a professional athlete who requires rapid return to competition. Current surgical treatment strategies include intramedullary nailing, which has satisfactory rates of fracture union but an associated risk of anterior knee pain. Anterior tension band plating is a biomechanically sound alternative treatment for these fractures. Tension band plating of chronic anterior tibial stress fractures leads to rapid healing and return to physical activity and avoids the anterior knee pain associated with intramedullary nailing. Case series; Level of evidence, 4. Between 2001 and 2013, there were 13 chronic anterior tibial stress fractures in 12 professional or collegiate athletes who underwent tension band plating after failing nonoperative management. Patient charts were retrospectively reviewed for demographics, injury history, and surgical details. Radiographs were used to assess time to osseous union. Follow-up notes and phone interviews were used to determine follow-up time, return to training time, and whether the patient was able to return to competition. Cases included 13 stress fractures in 12 patients (9 females, 3 males). Five patients were track-and-field athletes, 4 patients played basketball, 2 patients played volleyball, and 1 was a ballet dancer. Five patients were Division I collegiate athletes and 7 were professional or Olympic athletes. Average age at time of surgery was 23.6 years (range, 20-32 years). Osseous union occurred on average at 9.6 weeks (range, 5.3-16.9 weeks) after surgery. Patients returned to training on average at 11.1 weeks (range, 5.7-20 weeks). Ninety-two percent (12/13) eventually returned to preinjury competition levels. Thirty-eight percent (5/13) underwent removal of hardware for plate prominence. There was no incidence of infection or nonunion. Anterior tension band plating for chronic tibial stress

  9. Tension pneumothorax accompanied by type A aortic dissection.

    Science.gov (United States)

    Hifumi, Toru; Kiriu, Nobuaki; Inoue, Junichi; Koido, Yuichi

    2012-11-09

    A 51-year-old man was brought to the emergency room because of a sudden onset of severe dysponea. On presentation, his blood pressure was 94/55 mm Hg. Oxygen saturation was 86% while he was receiving 10 l/min oxygen through a non-rebreather mask. On physical examination, no jugular venous distention was noted, but breath sounds over the left lung were diminished. A bedside chest radiograph showed left tension pneumothorax, for which urgent needle decompression followed by chest thoracostomy was performed. Ventricular tachycardia developed, but a biphasic shock at 120 J immediately restored normal sinus rhythm. His vital signs, however, did not improve. A CT scan of the chest showed type A aortic dissection with bullae in the upper lobe of the left lung. He had an emergency operation for distal aortic arch displacement and was discharged on the 37th day of hospitalisation.

  10. Simultaneous sampling of tissue oxygenation and oxygen consumption in skeletal muscle.

    Science.gov (United States)

    Nugent, William H; Song, Bjorn K; Pittman, Roland N; Golub, Aleksander S

    2016-05-01

    Under physiologic conditions, microvascular oxygen delivery appears to be well matched to oxygen consumption in respiring tissues. We present a technique to measure interstitial oxygen tension (PISFO2) and oxygen consumption (VO2) under steady-state conditions, as well as during the transitions from rest to activity and back. Phosphorescence Quenching Microscopy (PQM) was employed with pneumatic compression cycling to achieve 1 to 10 Hz sampling rates of interstitial PO2 and simultaneous recurrent sampling of VO2 (3/min) in the exteriorized rat spinotrapezius muscle. The compression pressure was optimized to 120-130 mmHg without adverse effect on the tissue preparation. A cycle of 5s compression followed by 15s recovery yielded a resting VO2 of 0.98 ± 0.03 ml O2/100 cm(3)min while preserving microvascular oxygen delivery. The measurement system was then used to assess VO2 dependence on PISFO2 at rest and further tested under conditions of isometric muscle contraction to demonstrate a robust ability to monitor the on-kinetics of tissue respiration and the compensatory changes in PISFO2 during contraction and recovery. The temporal and spatial resolution of this approach is well suited to studies seeking to characterize microvascular oxygen supply and demand in thin tissues. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. High Selectivity Oxygen Delignification

    Energy Technology Data Exchange (ETDEWEB)

    Lucian A. Lucia

    2005-11-15

    Project Objective: The objectives of this project are as follows: (1) Examine the physical and chemical characteristics of a partner mill pre- and post-oxygen delignified pulp and compare them to lab generated oxygen delignified pulps; (2) Apply the chemical selectivity enhancement system to the partner pre-oxygen delignified pulps under mill conditions (with and without any predetermined amounts of carryover) to determine how efficiently viscosity is preserved, how well selectivity is enhanced, if strength is improved, measure any yield differences and/or bleachability differences; and (3) Initiate a mill scale oxygen delignification run using the selectivity enhancement agent, collect the mill data, analyze it, and propose any future plans for implementation.

  12. High temperature properties of Zircaloy--oxygen alloys

    International Nuclear Information System (INIS)

    Mellinger, G.B.; Bates, J.L.

    1977-03-01

    The effect of oxygen on three properties of Zircaloy-4 cladding relevant to LOCA evaluation codes was determined. Thermal expansion, elastic moduli, and thermal diffusivity were measured over the range room temperature--1200 0 C (2192 0 F) and 0.7 to 28 at.% oxygen. Thermal expansion and elastic moduli showed increases with oxygen concentration, while thermal diffusivity tended to decrease. Zircaloy-2 was examined over the same temperature range, but only to 5 at.% oxygen, differences in the properties between the two alloys were minor. The thermal emittance of Zircaloy-4 was measured in argon over the wavelength range 1.5 to 2.5 μm on previously oxidized tubing and on surfaces in the process of oxidizing in unlimited steam. For the latter, a high emittance (approximately 0.9) was reached at an oxide thickness of about 100 mg/dm 2 , and the tubing surface remained black and substoichiometric as oxidation continued at temperatures to 1200 0 C

  13. Rein tension acceptance in young horses in a voluntary test situation.

    Science.gov (United States)

    Christensen, J W; Zharkikh, T L; Antoine, A; Malmkvist, J

    2011-03-01

    During riding, horses are frequently exposed to pressure from the rider, e.g. through the bit and reins, but few studies have investigated at which point rein tension becomes uncomfortable for the horse. To investigate how much rein tension young inexperienced horses are willing to accept in order to obtain a food reward; whether the tension acceptance changes during 3 consecutive test days; and whether rein tension correlates with the expression of conflict behaviour and heart rate. Pressure-naïve horses will apply only little rein tension in the first voluntary trial, but their acceptance will gradually increase. High levels of rein tension will lead to expression of conflict behaviour and increases in heart rate. Fifteen 2-year-old, bridle-naïve mares were encouraged to stretch their head forward (across a 0.95 m high metal bar) to obtain a food reward in a voluntary test situation. On each test day, each horse was exposed to 2 control sessions (loose reins), an intermediate and a short rein session (1 min/session). Rein tension, heart rate and behaviour were recorded. The horses applied significantly more tension on the first day (mean rein tension: 10.2 N), compared to the second and third test day (Day 2: 6.0 and Day 3: 5.7 N). The horses showed significantly more conflict behaviour in the short rein treatment. There was no treatment effect on heart rate. The horses applied the highest rein tension on the first day, and apparently learned to avoid the tension, rather than habituate to it. Rein tension correlated with expression of conflict behaviour, indicating that the horses found the tension aversive. Further studies should focus on the correlation between rein tension and conflict behaviour in ridden horses. © 2010 EVJ Ltd.

  14. Rein tension acceptance in young horses in a voluntary test situation

    DEFF Research Database (Denmark)

    Christensen, Janne Winther; zharkikh, T.L.; Antoine, A.

    2011-01-01

    Reasons for performing the study: During riding, horses are frequently exposed to pressure from the rider, e.g. through the bit and reins, but few studies have investigated at which point rein tension becomes uncomfortable for the horse. Objectives: To investigate how much rein tension young...... inexperienced horses are willing to accept in order to obtain a food reward; whether the tension acceptance changes during 3 consecutive test days; and whether rein tension correlates with the expression of conflict behaviour and heart rate. Hypotheses: Pressure-naïve horses will apply only little rein tension...... in the first voluntary trial, but their acceptance will gradually increase. High levels of rein tension will lead to expression of conflict behaviour and increases in heart rate. Methods: Fifteen 2-year-old, bridle-naïve mares were encouraged to stretch their head forward (across a 0.95 m high metal bar...

  15. Low Oxygen Modulates Multiple Signaling Pathways, Increasing Self-Renewal, While Decreasing Differentiation, Senescence, and Apoptosis in Stromal MIAMI Cells

    Science.gov (United States)

    Rios, Carmen; D'Ippolito, Gianluca; Curtis, Kevin M.; Delcroix, Gaëtan J.-R.; Gomez, Lourdes A.; El Hokayem, Jimmy; Rieger, Megan; Parrondo, Ricardo; de las Pozas, Alicia; Perez-Stable, Carlos; Howard, Guy A.

    2016-01-01

    Human bone marrow multipotent mesenchymal stromal cell (hMSC) number decreases with aging. Subpopulations of hMSCs can differentiate into cells found in bone, vasculature, cartilage, gut, and other tissues and participate in their repair. Maintaining throughout adult life such cell subpopulations should help prevent or delay the onset of age-related degenerative conditions. Low oxygen tension, the physiological environment in progenitor cell-rich regions of the bone marrow microarchitecture, stimulates the self-renewal of marrow-isolated adult multilineage inducible (MIAMI) cells and expression of Sox2, Nanog, Oct4a nuclear accumulation, Notch intracellular domain, notch target genes, neuronal transcriptional repressor element 1 (RE1)-silencing transcription factor (REST), and hypoxia-inducible factor-1 alpha (HIF-1α), and additionally, by decreasing the expression of (i) the proapoptotic proteins, apoptosis-inducing factor (AIF) and Bak, and (ii) senescence-associated p53 expression and β-galactosidase activity. Furthermore, low oxygen increases canonical Wnt pathway signaling coreceptor Lrp5 expression, and PI3K/Akt pathway activation. Lrp5 inhibition decreases self-renewal marker Sox2 mRNA, Oct4a nuclear accumulation, and cell numbers. Wortmannin-mediated PI3K/Akt pathway inhibition leads to increased osteoblastic differentiation at both low and high oxygen tension. We demonstrate that low oxygen stimulates a complex signaling network involving PI3K/Akt, Notch, and canonical Wnt pathways, which mediate the observed increase in nuclear Oct4a and REST, with simultaneous decrease in p53, AIF, and Bak. Collectively, these pathway activations contribute to increased self-renewal with concomitant decreased differentiation, cell cycle arrest, apoptosis, and/or senescence in MIAMI cells. Importantly, the PI3K/Akt pathway plays a central mechanistic role in the oxygen tension-regulated self-renewal versus osteoblastic differentiation of progenitor cells. PMID:27059084

  16. OPTIMUM, CRITICAL AND THRESHOLD VALUES FOR WATER OXYGENATION FOR MULLETS (MUGILIDAE AND FLATFISHES (PLEURONECTIDAE IN ONTOGENESIS

    Directory of Open Access Journals (Sweden)

    P. Shekk

    2014-12-01

    Full Text Available Purpose. To determine the optimum, critical, and threshold values of water oxygenation for embryos, larvae and fingerlings of mullets and flatfishes under different temperature conditions. Methodology. Oxygen consumption was studied in chronic experiments with «interrupted flow» method with automatic fixation of dissolved oxygen in water with the aid of an oxygen sensor and automatic, continuous recording of the obtained results. «Critical» (Pcrit., and the «threshold» (Pthr. oxygen tension in the water have been determined. Findings. Under optimum conditions, the normal embryogenesis of mullets and flatfish to the gastrulation stage, provided 90–130% oxygen saturation. The critical content was 80–85%, the threshold – 65–70% of the saturation. At the stage of «movable embryo» depending on water temperature and fish species, the optimum range of water oxygenation was within 70‒127.1%. The most tolerant to oxygen deficiency was flounder Platichthys luscus (Pcrit – 25.4–27,5; Pthr. – 20.5–22.5%, the least resistant to hypoxia was striped mullet Mugil серhalus (Pcrit. – 50–60; Pthr. – 35–40%. The limits of the critical and threshold concentration of dissolved oxygen directly depended on the temperature and salinity, at which embryogenesis occurred. An increase in water temperature and salinity resulted in an increase in critical and threshold values for oxygen tension embryos. Mullet and flatfish fingerlings in all stages of development had a high tolerance to hypoxia, which increased as they grew. They were resistant to the oversaturation of water with oxygen. The most demanding for the oxygen regime are larvae and fingerlings of striped mullet and Liza aurata. Hypoxia tolerance of Psetta maeoticus (Psetta maeoticus and flounder at all stages of development is very high. The fingerlings of these species can endure reduction of the dissolved oxygen in water to 2.10 and 1.65 mgO2/dm3 respectively for a long time

  17. Optimizing the calculation of DM,CO and VC via the single breath single oxygen tension DLCO/NO method.

    Science.gov (United States)

    Coffman, Kirsten E; Taylor, Bryan J; Carlson, Alex R; Wentz, Robert J; Johnson, Bruce D

    2016-01-15

    Alveolar-capillary membrane conductance (D(M,CO)) and pulmonary-capillary blood volume (V(C)) are calculated via lung diffusing capacity for carbon monoxide (DL(CO)) and nitric oxide (DL(NO)) using the single breath, single oxygen tension (single-FiO2) method. However, two calculation parameters, the reaction rate of carbon monoxide with blood (θ(CO)) and the D(M,NO)/D(M,CO) ratio (α-ratio), are controversial. This study systematically determined optimal θ(CO) and α-ratio values to be used in the single-FiO2 method that yielded the most similar D(M,CO) and V(C) values compared to the 'gold-standard' multiple-FiO2 method. Eleven healthy subjects performed single breath DL(CO)/DL(NO) maneuvers at rest and during exercise. D(M,CO) and V(C) were calculated via the single-FiO2 and multiple-FiO2 methods by implementing seven θ(CO) equations and a range of previously reported α-ratios. The RP θ(CO) equation (Reeves, R.B., Park, H.K., 1992. Respiration Physiology 88 1-21) and an α-ratio of 4.0-4.4 yielded DM,CO and VC values that were most similar between methods. The RP θ(CO) equation and an experimental α-ratio should be used in future studies. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. High-pressure oxygenation of thin-wall YBCO single-domain samples

    International Nuclear Information System (INIS)

    Chaud, X; Savchuk, Y; Sergienko, N; Prikhna, T; Diko, P

    2008-01-01

    The oxygen annealing of ReBCO bulk material, necessary to achieve superconducting properties, usually induces micro- and macro-cracks. This leads to a crack-assisted oxygenation process that allows oxygenating large bulk samples faster than single crystals. But excellent superconducting properties are cancelled by the poor mechanical ones. More progressive oxygenation strategy has been shown to reduce drastically the oxygenation cracks. The problem then arises to keep a reasonable annealing time. The concept of bulk Y123 single-domain samples with thin-wall geometry has been introduced to bypass the inherent limitation due to a slow oxygen diffusion rate. But it is not enough. The use of a high oxygen pressure (16 MPa) enables to speed up further the process. It introduces a displacement in the equilibrium phase diagram towards higher temperatures, i.e., higher diffusion rates, to achieve a given oxygen content in the material. Remarkable results were obtained by applying such a high pressure oxygen annealing process on thin-wall single-domain samples. The trapped field of 16 mm diameter Y123 thin-wall single-domain samples was doubled (0.6T vs 0.3T at 77K) using an annealing time twice shorter (about 3 days). The initial development was made on thin bars. The advantage of thin-wall geometry is that such an annealing can be applied directly to a much larger sample

  19. Dissolved oxygen concentration in the medium during cell culture: Defects and improvements.

    Science.gov (United States)

    Zhang, Kuan; Zhao, Tong; Huang, Xin; He, Yunlin; Zhou, Yanzhao; Wu, Liying; Wu, Kuiwu; Fan, Ming; Zhu, Lingling

    2016-03-01

    In vitro cell culture has provided a useful model to study the effects of oxygen on cellular behavior. However, it remains unknown whether the in vitro operations themselves affect the medium oxygen levels and the living states of cells. In addition, a prevailing controversy is whether reactive oxygen species (ROS) production is induced by continuous hypoxia or reoxygenation. In this study, we have measured the effects of different types of cell culture containers and the oxygen environment where medium replacement takes place on the actual oxygen tension in the medium. We found that the deviations of oxygen concentrations in the medium are much greater in 25-cm(2) flasks than in 24-well plates and 35-mm dishes. The dissolved oxygen concentrations in the medium were increased after medium replacement in normoxia, but remained unchanged in glove boxes in which the oxygen tension remained at a low level (11.4, 5.7, and 0.5% O2 ). We also found that medium replacement in normoxia increased the number of ROS-positive cells and reduced the cell viability; meanwhile, medium replacement in a glove box did not produce the above effects. Therefore, we conclude that the use of 25-cm(2) flasks should be avoided and demonstrate that continuous hypoxia does not produce ROS, whereas the reoxygenation that occurs during the harvesting of cells leads to ROS and induces cell death. © 2015 International Federation for Cell Biology.

  20. Optimizing oxygenation and intubation conditions during awake fibre-optic intubation using a high-flow nasal oxygen-delivery system.

    Science.gov (United States)

    Badiger, S; John, M; Fearnley, R A; Ahmad, I

    2015-10-01

    Awake fibre-optic intubation is a widely practised technique for anticipated difficult airway management. Despite the administration of supplemental oxygen during the procedure, patients are still at risk of hypoxia because of the effects of sedation, local anaesthesia, procedural complications, and the presence of co-morbidities. Traditionally used oxygen-delivery devices are low flow, and most do not have a sufficient reservoir or allow adequate fresh gas flow to meet the patient's peak inspiratory flow rate, nor provide an adequate fractional inspired oxygen concentration to prevent desaturation should complications arise. A prospective observational study was conducted using a high-flow humidified transnasal oxygen-delivery system during awake fibre-optic intubation in 50 patients with anticipated difficult airways. There were no episodes of desaturation or hypercapnia using the high-flow system, and in all patients the oxygen saturation improved above baseline values, despite one instance of apnoea resulting from over-sedation. All patients reported a comfortable experience using the device. The high-flow nasal oxygen-delivery system improves oxygenation saturation, decreases the risk of desaturation during the procedure, and potentially, optimizes conditions for awake fibre-optic intubation. The soft nasal cannulae uniquely allow continuous oxygenation and simultaneous passage of the fibrescope and tracheal tube. The safety of the procedure may be increased, because any obstruction, hypoventilation, or periods of apnoea that may arise may be tolerated for longer, allowing more time to achieve ventilation in an optimally oxygenated patient. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. High-Pressure Oxygen Generation for Outpost EVA Study

    Science.gov (United States)

    Jeng, Frank F.; Conger, Bruce; Ewert, Michael K.; Anderson, Molly S.

    2009-01-01

    The amount of oxygen consumption for crew extravehicular activity (EVA) in future lunar exploration missions will be significant. Eight technologies to provide high pressure EVA O2 were investigated. They are: high pressure O2 storage, liquid oxygen (LOX) storage followed by vaporization, scavenging LOX from Lander followed by vaporization, LOX delivery followed by sorption compression, water electrolysis followed by compression, stand-alone high pressure water electrolyzer, Environmental Control and Life Support System (ECLSS) and Power Elements sharing a high pressure water electrolyzer, and ECLSS and In-Situ Resource Utilization (ISRU) Elements sharing a high pressure electrolyzer. A trade analysis was conducted comparing launch mass and equivalent system mass (ESM) of the eight technologies in open and closed ECLSS architectures. Technologies considered appropriate for the two architectures were selected and suggested for development.

  2. Prompt meningeal reconstruction mediated by oxygen-sensitive AKAP12 scaffolding protein after central nervous system injury

    Science.gov (United States)

    Cha, Jong-Ho; Wee, Hee-Jun; Seo, Ji Hae; Ahn, Bum Ju; Park, Ji-Hyeon; Yang, Jun-Mo; Lee, Sae-Won; Lee, Ok-Hee; Lee, Hyo-Jong; Gelman, Irwin H.; Arai, Ken; Lo, Eng H.; Kim, Kyu-Won

    2015-01-01

    The meninges forms a critical epithelial barrier, which protects the central nervous system (CNS), and therefore its prompt reconstruction after CNS injury is essential for reducing neuronal damage. Meningeal cells migrate into the lesion site after undergoing an epithelial-mesenchymal transition (EMT) and repair the impaired meninges. However, the molecular mechanisms of meningeal EMT remain largely undefined. Here we show that TGF-β1 and retinoic acid (RA) released from the meninges, together with oxygen tension, could constitute the mechanism for rapid meningeal reconstruction. AKAP12 is an effector of this mechanism, and its expression in meningeal cells is regulated by integrated upstream signals composed of TGF-β1, RA and oxygen tension. Functionally, AKAP12 modulates meningeal EMT by regulating the TGF-β1-non-Smad-SNAI1 signalling pathway. Collectively, TGF-β1, RA and oxygen tension can modulate the dynamic change in AKAP12 expression, causing prompt meningeal reconstruction after CNS injury by regulating the transition between the epithelial and mesenchymal states of meningeal cells. PMID:25229625

  3. Cerebral oxygenation decreases during exercise in humans with beta-adrenergic blockade

    DEFF Research Database (Denmark)

    Seifert, T.; Rasmussen, P.; Secher, Niels H.

    2009-01-01

    AIM: Beta-blockers reduce exercise capacity by attenuated increase in cardiac output, but it remains unknown whether performance also relates to attenuated cerebral oxygenation. METHODS: Acting as their own controls, eight healthy subjects performed a continuous incremental cycle test to exhaustion...... attenuated the increase in cardiac output of consequence for cerebral perfusion and oxygenation. We suggest that a decrease in cerebral oxygenation limits exercise capacity Udgivelsesdato: 2009/7...... with or without administration of the non-selective beta-blocker propranolol. Changes in cerebral blood flow velocity were measured with transcranial Doppler ultrasound and those in cerebral oxygenation were evaluated using near-infrared spectroscopy and the calculated cerebral mitochondrial oxygen tension...

  4. Abnormal pain processing in chronic tension-type headache: a high-density EEG brain mapping study

    DEFF Research Database (Denmark)

    Buchgreitz, L.; Egsgaard, L.L.; Jensen, R.

    2008-01-01

    Central sensitization caused by prolonged nociceptive input from muscles is considered to play an important role for chronification of tension-type headache. In the present study we used a new high-density EEG brain mapping technique to investigate spatiotemporal aspects of brain activity...... in response to muscle pain in 19 patients with chronic tension-type headache (CTTH) and 19 healthy, age- and sex-matched controls. Intramuscular electrical stimuli (single and train of five pulses delivered at 2 Hz) were applied to the trapezius muscle and somatosensory evoked potentials were recorded...... with 128-channel EEG both in- and outside a condition with induced tonic neck/shoulder muscle pain (glutamate injection into the trapezius muscle). Significant reduction in magnitude during and after induced tonic muscle pain was found in controls at the P200 dipole in response to both the first (baseline...

  5. Reduced-Gravity Measurements of the Effect of Oxygen on Properties of Zirconium

    Science.gov (United States)

    Zhao, J.; Lee, J.; Wunderlich, R.; Fecht, H.-J.; Schneider, S.; SanSoucie, M.; Rogers, J.; Hyers, R.

    2016-01-01

    The influence of oxygen on the thermophysical properties of zirconium is being investigated using MSL-EML (Material Science Laboratory - Electromagnetic Levitator) on ISS (International Space Station) in collaboration with NASA, ESA (European Space Agency), and DLR (German Aerospace Center). Zirconium samples with different oxygen concentrations will be put into multiple melt cycles, during which the density, viscosity, surface tension, heat capacity, and electric conductivity will be measured at various undercooled temperatures. The facility check-up of MSL-EML and the first set of melting experiments have been successfully performed in 2015. The first zirconium sample will be tested near the end of 2015. As part of ground support activities, the thermophysical properties of zirconium and ZrO were measured using a ground-based electrostatic levitator located at the NASA Marshall Space Flight Center. The influence of oxygen on the measured surface tension was evaluated. The results of this research will serve as reference data for those measured in ISS.

  6. Effects of motexafin gadolinium on tumor oxygenation and cellular oxygen consumption

    International Nuclear Information System (INIS)

    Donnelly, E.T.; Liu, Y.; Rockwell, S.; Magda, D.

    2003-01-01

    Full text: Recent work in our laboratory showed that motexafin gadolinium (MGd, Xcytrin), a drug currently in Phase III clinical trials as an adjuvant to radiation therapy, modulates the oxygen tensions in EMT6 tumors. The median pO 2 increased from the control value of 1.5±0.4 mmHg to 7.4 ± 3.8 mmHg six hours after treatment with 40 μmol/kg MGd and the percentage of severely hypoxic readings in the tumors ( 7 plateau phase EMT6 cells in 3 mL Dulbecco's Modified Eagle's Medium supplemented with 10% dialyzed fetal bovine serum, which contains no ascorbic acid. In the absence of ascorbic acid, 100 μM MGd did not alter the cellular oxygen consumption rate for EMT6 cells significantly. Marked inhibition of cellular oxygen consumption was observed when cells were incubated with 100 μM MGd in medium supplemented with equimolar ascorbic acid (a 31.5% decrease in consumption was observed after 6 hours of treatment). The 5% mannitol vehicle solution with equimolar ascorbic acid had no discernible effect on cellular oxygen consumption. Ascorbic acid may facilitate cellular uptake of MGd via the intermediate formation of a MGd-oxalate complex. These studies suggest that changes in cellular oxygen consumption could contribute to the changes in tumor oxygenation seen after administration of MGd. These experiments were supported by Pharmacyclics and training grant T32CA09085 from the NIH (E.T.D.). We thank Dr. Raymond Russell for allowing us to use his oxygen electrode apparatus

  7. The state of emotional tension of tennis sportswomen-players of high qualification

    Directory of Open Access Journals (Sweden)

    Uliz'ko V.M.

    2010-06-01

    Full Text Available An analysis and distributing of sportswomen is presented to on by the degree of expressed a personality and situation anxiety. 40 sportswomen took part in research. The psychophysiological functional state of man is studied in the conditions of high psychoemotional tension. The features of psychological mood are examined taking into account personality descriptions of every sportsman. Sporting achievement is the result of cooperation of external (financial, material and internal (attitude toward trainings, presence of genetic preconditions factors. External factors are mediated influence on success and cause for a sportsman the subjective states with the proper conduct.

  8. Differential oxygen dynamics in two diverse Dunning prostate R3327 rat tumor sublines (MAT-Lu and HI) with respect to growth and respiratory challenge

    International Nuclear Information System (INIS)

    Zhao Dawen; Constantinescu, Anca; Hahn, Eric W.; Mason, Ralph P.

    2002-01-01

    Purpose: Since hypoxia may influence tumor response to therapy and prognosis, we have compared oxygenation of tumors known to exhibit differential growth rate and tissue differentiation. Methods and Materials: Regional tumor oxygen tension was measured using 19 F nuclear magnetic resonance echo planar imaging relaxometry of hexafluorobenzene, which provided dynamic maps with respect to respiratory intervention. Investigations used two Dunning prostate R3327 rat tumor sublines: the fast growing, highly metastatic MAT-Lu and the moderately well-differentiated, slower growing HI. Results: Both sublines showed significantly higher oxygen tension in smaller tumors ( 3 ) than in larger tumors (>3.5 cm 3 ). Pooled data showed that MAT-Lu tumors exhibited greater hypoxia compared with the size-matched HI tumors (p 2 for tumors of both sublines (p 2 , while those in the MAT-Lu tumors showed little response to respiratory intervention. Conclusions: These results concur with hypotheses that hypoxia is related to tumor growth rate and degree of differentiation. Under baseline conditions, the differences were subtle. However, response to respiratory intervention revealed highly significant differences, which, if held valid in the clinic, could have prognostic value

  9. Tension pneumothorax, is it a really life-threatening condition?

    Science.gov (United States)

    2013-01-01

    Background Tension pneumothorax is a life-threatening occurrence that is infrequently the consequence of spontaneous pneumothorax. The aim of this study was to identify the risk factors for the development of tension pneumothorax and its effect on clinical outcomes. Methods We reviewed patients who were admitted with spontaneous pneumothorax between August 1, 2003 and December 31, 2011. Electronic medical records and the radiological findings were reviewed with chest x-ray and high-resolution computed tomography scans that were retrieved from the Picture Archiving Communication System. Results Out of the 370 patients included in this study, tension pneumothorax developed in 60 (16.2%). The bullae were larger in patients with tension pneumothorax than in those without (23.8 ± 16.2 mm vs 16.1 ± 19.1 mm; P = 0.007). In addition, the incidence of tension pneumothorax increased with the lung bulla size. Fibrotic adhesion was more prevalent in the tension pneumothorax group than in that without (P = 0.000). The bullae were large in patients with fibrotic adhesion than in those without adhesion (35.0 ± 22.3 mm vs 10.4 ± 11.5 mm; P = 0.000). On multivariate analysis, the size of bullae (odds ratio (OR) = 1.03, P = 0.001) and fibrotic adhesion (OR = 10.76, P = 0.000) were risk factors of tension pneumothorax. Hospital mortality was 3.3% in the tension pneumothorax group and it was not significantly different from those patients without tension pneunothorax (P = 0.252). Conclusions Tension pneumothorax is not uncommon, but clinically fatal tension pneumothorax is extremely rare. The size of the lung bullae and fibrotic adhesion contributes to the development of tension pneumothorax. PMID:24128176

  10. Developing a Customized Perfusion Bioreactor Prototype with Controlled Positional Variability in Oxygen Partial Pressure for Bone and Cartilage Tissue Engineering.

    Science.gov (United States)

    Lee, Poh Soo; Eckert, Hagen; Hess, Ricarda; Gelinsky, Michael; Rancourt, Derrick; Krawetz, Roman; Cuniberti, Gianaurelio; Scharnweber, Dieter

    2017-05-01

    Skeletal development is a multistep process that involves the complex interplay of multiple cell types at different stages of development. Besides biochemical and physical cues, oxygen tension also plays a pivotal role in influencing cell fate during skeletal development. At physiological conditions, bone cells generally reside in a relatively oxygenated environment whereas chondrocytes reside in a hypoxic environment. However, it is technically challenging to achieve such defined, yet diverse oxygen distribution on traditional in vitro cultivation platforms. Instead, engineered osteochondral constructs are commonly cultivated in a homogeneous, stable environment. In this study, we describe a customized perfusion bioreactor having stable positional variability in oxygen tension at defined regions. Further, engineered collagen constructs were coaxed into adopting the shape and dimensions of defined cultivation platforms that were precasted in 1.5% agarose bedding. After cultivating murine embryonic stem cells that were embedded in collagen constructs for 50 days, mineralized constructs of specific dimensions and a stable structural integrity were achieved. The end-products, specifically constructs cultivated without chondroitin sulfate A (CSA), showed a significant increase in mechanical stiffness compared with their initial gel-like constructs. More importantly, the localization of osteochondral cell types was specific and corresponded to the oxygen tension gradient generated in the bioreactor. In addition, CSA in complementary with low oxygen tension was also found to be a potent inducer of chondrogenesis in this system. In summary, we have demonstrated a customized perfusion bioreactor prototype that is capable of generating a more dynamic, yet specific cultivation environment that could support propagation of multiple osteochondral lineages within a single engineered construct in vitro. Our system opens up new possibilities for in vitro research on human

  11. Reduced oxygen at high altitude limits maximum size.

    Science.gov (United States)

    Peck, L S; Chapelle, G

    2003-11-07

    The trend towards large size in marine animals with latitude, and the existence of giant marine species in polar regions have long been recognized, but remained enigmatic until a recent study showed it to be an effect of increased oxygen availability in sea water of a low temperature. The effect was apparent in data from 12 sites worldwide because of variations in water oxygen content controlled by differences in temperature and salinity. Another major physical factor affecting oxygen content in aquatic environments is reduced pressure at high altitude. Suitable data from high-altitude sites are very scarce. However, an exceptionally rich crustacean collection, which remains largely undescribed, was obtained by the British 1937 expedition from Lake Titicaca on the border between Peru and Bolivia in the Andes at an altitude of 3809 m. We show that in Lake Titicaca the maximum length of amphipods is 2-4 times smaller than other low-salinity sites (Caspian Sea and Lake Baikal).

  12. Interfacial Tension and Surface Pressure of High Density Lipoprotein, Low Density Lipoprotein, and Related Lipid Droplets

    DEFF Research Database (Denmark)

    Ollila, O. H. S.; Lamberg, A.; Lehtivaara, M.

    2012-01-01

    ) are essentially lipid droplets surrounded by specific proteins, their main function being to transport cholesterol. Interfacial tension and surface pressure of these particles are of great interest because they are related to the shape and the stability of the droplets and to protein adsorption at the interface....... Here we use coarse-grained molecular-dynamics simulations to consider a number of related issues by calculating the interfacial tension in protein-free lipid droplets, and in HDL and LDL particles mimicking physiological conditions. First, our results suggest that the curvature dependence......Lipid droplets play a central role in energy storage and metabolism on a cellular scale. Their core is comprised of hydrophobic lipids covered by a surface region consisting of amphiphilic lipids and proteins. For example, high and low density lipoproteins (HDL and LDL, respectively...

  13. Reactor vessel stud tensioner

    International Nuclear Information System (INIS)

    Malandra, L.J.; Beer, R.W.; Salton, R.B.; Spiegelman, S.R.; Cognevich, M.L.

    1982-01-01

    A quick-acting stud tensioner, for facilitating the loosening or tightening of a stud nut on a reactor vessel stud, has gripper jaws which when the tensioner is lowered into engagement with the upper end of the stud are moved inwards to grip the upper end and which when the tensioner is lifted move outward to release the upper end. (author)

  14. A high reliability oxygen deficiency monitoring system

    International Nuclear Information System (INIS)

    Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.

    1993-05-01

    The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings

  15. A high reliability oxygen deficiency monitoring system

    International Nuclear Information System (INIS)

    Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.

    1993-01-01

    The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings

  16. Anterior tibial stress fractures treated with anterior tension band plating in high-performance athletes.

    Science.gov (United States)

    Cruz, Alexandre Santa; de Hollanda, João Paris Buarque; Duarte, Aires; Hungria Neto, José Soares

    2013-06-01

    The non-surgical treatment of anterior tibial cortex stress fractures requires long periods of abstention from sports activities and often results in non-union. Many different surgical techniques have already been previously described to treat these fractures, but there is no consensus on the best treatment. We describe the outcome of treatment using anterior tibial tension band plating in three high-performance athletes (4 legs) with anterior tibial cortex stress fractures. Tibial osteosynthesis with a 3.5-mm locking compression plate in the anterolateral aspect of the tibia was performed in all patients diagnosed with anterior tibial stress fracture after September 2010 at Santa Casa Hospital. All of the fractures were consolidated within a period of 3 months after surgery, allowing for an early return to pre-injury levels of competitive sports activity. There were no infection, non-union, malunion or anterior knee pain complications. Anterior tibial tension band plating leads to prompt fracture consolidation and is a good alternative for the treatment of anterior tibial cortex stress fractures. Bone grafts were shown to be unnecessary.

  17. Creating Tension in Writing.

    Science.gov (United States)

    Folta, Bernarr

    This paper discusses the rationale and teaching methods for a six-week unit, for a high school freshman English Class, on perception, semantics, and writing, which places special focus on developing tension in student writing. The first four objectives of the course focus on perception and the next two focus on semantics. The seventh…

  18. The development of the high-tension wire for nuclear fusion superconductive magnet measurement

    International Nuclear Information System (INIS)

    Yoshida, Kiyoshi; Morita, Yohsuke; Yamazaki, Takanori; Watanabe, Kiyoshi; Furusawa, Ken-ichi.

    1987-01-01

    Following on tokamak critical plasma testing device JT-60, experimental fusion reactor JT-100 is being developed. The 6 kV high-tension wire has been developed for use in JT-100 under ultra-low temperature and high radiation environment. Used for superconductive magnet measurement, the wire is inserted in the vacuum vessel, being immersed within the liquid helium. As the insulating material of this wire, polyetherimido was found to be most suitable in the respects of radiation resistance and voltage-withstand property. In an electric wire covered with polyetherimido, which was made in trial, its test in voltage-withstand and bending characteristics at ultra-low temperature showed the wire to be usable for the intended purpose. (Mori, K.)

  19. Z(2) vortices and the SU(2) string tension

    International Nuclear Information System (INIS)

    Goepfert, M.

    1981-01-01

    Topologically determined Z(2) variables in pure SU(2) lattice gauge theory are discussed. They count the number of 'vortex souls'. The high temperature expansion for the corresponding Z(2) loops is examined. They obey an area law. The coefficient of the area is shown to be equal to the string tension to all orders of the high temperature expansion. This shows that the string tension is determined by the probability distribution of the vortex souls, at least in the high temperature region. The dependence of the string tension α(β,h) on an external field h that is coupled to the Z(2) field strength is calculated to lowest order of the high temperature expansion. In this approximation, α(β,h) is determined by the free energy of a 2-dimensional Ising model in an external magnetic field 1/2log(β/4tanhh) at an inverse temperature 1/2log3/4π = 0.429. (orig.)

  20. Bimodular high temperature planar oxygen gas sensor

    Directory of Open Access Journals (Sweden)

    Xiangcheng eSun

    2014-08-01

    Full Text Available A bimodular planar O2 sensor was fabricated using NiO nanoparticles (NPs thin film coated yttria-stabilized zirconia (YSZ substrate. The thin film was prepared by radio frequency (r.f. magnetron sputtering of NiO on YSZ substrate, followed by high temperature sintering. The surface morphology of NiO nanoparticles film was characterized by atomic force microscopy (AFM and scanning electron microscopy (SEM. X-ray diffraction (XRD patterns of NiO NPs thin film before and after high temperature O2 sensing demonstrated that the sensing material possesses a good chemical and structure stability. The oxygen detection experiments were performed at 500 °C, 600 °C and 800 °C using the as-prepared bimodular O2 sensor under both potentiometric and resistance modules. For the potentiometric module, a linear relationship between electromotive force (EMF output of the sensor and the logarithm of O2 concentration was observed at each operating temperature, following the Nernst law. For the resistance module, the logarithm of electrical conductivity was proportional to the logarithm of oxygen concentration at each operating temperature, in good agreement with literature report. In addition, this bimodular sensor shows sensitive, reproducible and reversible response to oxygen under both sensing modules. Integration of two sensing modules into one sensor could greatly enrich the information output and would open a new venue in the development of high temperature gas sensors.

  1. Pericellular oxygen monitoring with integrated sensor chips for reproducible cell culture experiments.

    Science.gov (United States)

    Kieninger, J; Aravindalochanan, K; Sandvik, J A; Pettersen, E O; Urban, G A

    2014-04-01

    Here we present an application, in two tumour cell lines, based on the Sensing Cell Culture Flask system as a cell culture monitoring tool for pericellular oxygen sensing. T-47D (human breast cancer) and T98G (human brain cancer) cells were cultured either in atmospheric air or in a glove-box set at 4% oxygen, in both cases with 5% CO2 in the gas phase. Pericellular oxygen tension was measured with the help of an integrated sensor chip comprising oxygen sensor arrays. Obtained results illustrate variation of pericellular oxygen tension in attached cells covered by stagnant medium. Independent of incubation conditions, low pericellular oxygen concentration levels, usually associated with hypoxia, were found in dense cell cultures. Respiration alone brought pericellular oxygen concentration down to levels which could activate hypoxia-sensing regulatory processes in cultures believed to be aerobic. Cells in culture believed to experience conditions of mild hypoxia may, in reality, experience severe hypoxia. This would lead to incorrect assumptions and suggests that pericellular oxygen concentration readings are of great importance to obtain reproducible results when dealing with hypoxic and normoxic (aerobic) incubation conditions. The Sensing Cell Culture Flask system allows continuous monitoring of pericellular oxygen concentration with outstanding long-term stability and no need for recalibration during cell culture experiments. The sensor is integrated into the flask bottom, thus in direct contact with attached cells. No additional equipment needs to be inserted into the flask during culturing. Transparency of the electrochemical sensor chip allows optical inspection of cells attached on top of the sensor. © 2014 John Wiley & Sons Ltd.

  2. Discrepancies between measured changes of radiobiological hypoxic fraction and oxygen tension monitoring using two assay systems

    International Nuclear Information System (INIS)

    Sasai, K.; Brown, J.M.

    1994-01-01

    This study was conducted to assess the ability of computerized pO 2 histography to measure changes in tumor oxygenation produced by low oxygen breathing. Female syngeneic C3H/Km mice bearing SCC VII/St carcinomas were used in these experiments. Changes in tumor oxygenation produced by the mice breathing 10% oxygen were assessed with computerized pO2 histography, 3 H-misonidazole binding, and the paired survival curve assay of radiosensitivity. The hypoxic cell fraction of the tumors in mice breathing 10% oxygen was 3.1 times higher than that of tumors in mice breathing normal air determined by an in vivo-in vitro clonogenic assay. Binding of radiolabeled misonidazole to the tumors in mice breathing 10% oxygen was also significantly higher than that to tumors in mice breathing normal air (p 2 value for the tumor. The number of pO 2 readings lower than 5 mmHg in the tumor was not affected by the 10% oxygen breathing. These findings indicate that increases in radiobiological hypoxic fraction produced by lower blood oxygen levels may not correlate well with the results of polarographic measurements of tumor pO 2 levels. 29 refs., 4 figs., 1 tab

  3. Solving the tension between high-scale inflation and axion isocurvature perturbations

    International Nuclear Information System (INIS)

    Higaki, Tetsutaro; Takahashi, Fuminobu; Tokyo Univ., Kashiwa

    2014-03-01

    The BICEP2 experiment determined the Hubble parameter during inflation to be about 10 14 GeV. Such high inflation scale is in tension with the QCD axion dark matter if the Peccei-Quinn (PQ) symmetry remains broken during and after inflation, because too large axion isocurvature perturbations would be generated. The axion isocurvature perturbations can be suppressed if the axion acquires a sufficiently heavy mass during inflation. We show that this is realized if the PQ symmetry is explicitly broken down to a discrete symmetry and if the breaking is enhanced during inflation. We also show that, even when the PQ symmetry becomes spontaneously broken after inflation, such a temporarily enhanced PQ symmetry breaking relaxes the constraint on the axion decay constant.

  4. Liquid oxygen liquid acquisition device bubble point tests with high pressure lox at elevated temperatures

    Science.gov (United States)

    Jurns, J. M.; Hartwig, J. W.

    2012-04-01

    When transferring propellant in space, it is most efficient to transfer single phase liquid from a propellant tank to an engine. In earth's gravity field or under acceleration, propellant transfer is fairly simple. However, in low gravity, withdrawing single-phase fluid becomes a challenge. A variety of propellant management devices (PMDs) are used to ensure single-phase flow. One type of PMD, a liquid acquisition device (LAD) takes advantage of capillary flow and surface tension to acquire liquid. The present work reports on testing with liquid oxygen (LOX) at elevated pressures (and thus temperatures) (maximum pressure 1724 kPa and maximum temperature 122 K) as part of NASA's continuing cryogenic LAD development program. These tests evaluate LAD performance for LOX stored in higher pressure vessels that may be used in propellant systems using pressure fed engines. Test data shows a significant drop in LAD bubble point values at higher liquid temperatures, consistent with lower liquid surface tension at those temperatures. Test data also indicates that there are no first order effects of helium solubility in LOX on LAD bubble point prediction. Test results here extend the range of data for LOX fluid conditions, and provide insight into factors affecting predicting LAD bubble point pressures.

  5. High-power generator of singlet oxygen

    Czech Academy of Sciences Publication Activity Database

    Jirásek, Vít; Čenský, Miroslav; Špalek, Otomar; Kodymová, Jarmila

    2013-01-01

    Roč. 36, č. 10 (2013), s. 1755-1763 ISSN 0930-7516 Grant - others:Laser Science and Technology Centre(IN) LASTEC/FE/RKT/54/10-11 Institutional research plan: CEZ:AV0Z10100523 Keywords : high-pressure singlet oxygen generator * spray generator * centrifugal separation Subject RIV: BH - Optics, Masers, Lasers Impact factor: 2.175, year: 2013

  6. Phenylephrine Decreases Vascular Tension in Goat Arteries in Specific Circumstances.

    Directory of Open Access Journals (Sweden)

    Renu R Raj

    Full Text Available Phenylephrine (PE causes vasoconstriction through alpha adrenergic receptors. PE-induced vasodilatation has also been reported earlier in pre-constricted vessels. Here we demonstrate in spiral strips of goat arteries that addition of PE can decrease tone even from base-line levels (i.e. not pre-constricted and show that this process requires nitric oxide (NO and alpha adrenergic stimulation, but is cGMP-independent. Under control conditions, PE caused vasoconstriction, but under conditions where NO levels are higher, as with L-Arginine or sodium nitroprusside, PE decreased vessel tension. L-Arginine/PE combination was not able to decrease tension when alpha adrenoceptors were blocked with Phentolamine or endothelial nitric oxide synthase (eNOS was blocked with Nω-Nitro-L-arginine (L-NNA. Propranolol, a beta blocker, was unable to prevent the reduction in tension by the L-Arginine/PE combination. Adrenaline and noradrenaline (and not isoproterenol also reduced vessel tension in the presence of L-Arginine. Even when NO levels were not enhanced, relieving NO from having to stimulate the enzyme soluble guanylyl cyclase (sGC (either by using sGC blockers, namely ODQ or methylene blue, or by enhancing cGMP levels (with sildenafil which by negative feedback probably inhibits sGC led to PE-induced reduction of vascular tension. PMA-phorbol myristate acetate-an agonist which stimulates Protein Kinase C was able to prevent the ability of PE to reduce vascular tension in a high NO environment. Our conclusion is that PE reduces vascular tension through alpha adrenoceptors if there is excess NO availability to activate a putative pathway. Though the reduction of vessel tone by PE is dependent on NO, it is independent of cGMP. Prior treatment with PMA or PE itself can prevent further PE-induced reduction of tension in a high NO environment. The results here suggest, counter-intuitively, that alpha blockers may be of help in the treatment of septic shock

  7. Surface tension mediated conversion of light to work

    Science.gov (United States)

    Okawa, David; Pastine, Stefan J; Zettl, Alexander K; Frechet, Jean M. J

    2014-12-02

    Disclosed are a method and apparatus for converting light energy to mechanical energy by modification of surface tension on a supporting fluid. The apparatus comprises an object which may be formed as a composite object comprising a support matrix and a highly light absorptive material. The support matrix may comprise a silicon polymer. The highly light absorptive material may comprise vertically aligned carbon nanotubes (VANTs) embedded in the support matrix. The composite object is supported on a fluid. By exposing the highly light absorptive material to light, heat is generated, which changes the surface tension of the composite object, causing it to move physically within the fluid.

  8. The effects of high perioperative inspiratory oxygen fraction for adult surgical patients

    DEFF Research Database (Denmark)

    Wetterslev, Jørn; Meyhoff, Christian S; Jørgensen, Lars N

    2015-01-01

    BACKGROUND: Available evidence on the effects of a high fraction of inspired oxygen (FIO2) of 60% to 90% compared with a routine fraction of inspired oxygen of 30% to 40%, during anaesthesia and surgery, on mortality and surgical site infection has been inconclusive. Previous trials and meta......-analyses have led to different conclusions on whether a high fraction of supplemental inspired oxygen during anaesthesia may decrease or increase mortality and surgical site infections in surgical patients. OBJECTIVES: To assess the benefits and harms of an FIO2 equal to or greater than 60% compared...... and reran the searches in March 2015. We will consider two studies of interest when we update the review. SELECTION CRITERIA: We included randomized clinical trials that compared a high fraction of inspired oxygen with a routine fraction of inspired oxygen during anaesthesia, surgery and recovery...

  9. Ultimate stress increase in unbonded tendons in post-tensioned indeterminate I-beams cast with high strength normal and self compacting concrete

    Directory of Open Access Journals (Sweden)

    Yousef Askari Dolatabad

    2018-06-01

    Full Text Available The use of un-bonded tendons is prevalent in post-tensioned concrete structures. Equations for prediction of stress in un-bonded tendons of post-tensioned normal (vibrating concrete flexural members have been given in various codes. They are based on experience and don’t account all of important parameters such as concrete strength (normal and high strength and its type (vibrating and non-vibrating concrete. Since self-compacting concrete (SCC is nearly a new innovation therefore, understanding the implementation of this type of non-vibrating concrete on the ultimate unbonded tendon stress is critical. For this aim, in this paper there are presented experimental results of six continuous un-bonded post-tensioned I-beams in two groups were casted and monitored by different electrical strain gauges. In the first tested group, the beams (UPN1-12, UPN1-18, UPN1-22 were consisting of high strength normal concrete (HSNC where as in the second group (UPS1-12, UPS1-18, UPS1-22 high strength self-compacting concrete (HSSCC were tested. The variables included the type of concrete and percentage of bounded non-prestressed steel. Experimental monitored results of ultimate stress increase in unbonded tendons are compared with predicted equations of different researchers and standards. It was found that, the proposed equation is in better agreement with the test results. The results of standard error of estimate Sy/x, indicates that for two types of HSCs, the ACI 318-2011 provides better estimates than AASHTO-2010 model whereas this model provides better estimates than BS 8110-97. Keywords: Post-tensioned, Unbonded tendons, Stress increase, High strength normal and self-compacting concrete, Continuous beams

  10. Quantitative evaluation of the mitochondrial proteomes of Drosophila melanogaster adapted to extreme oxygen conditions.

    Directory of Open Access Journals (Sweden)

    Songyue Yin

    Full Text Available Mitochondria are the primary organelles that consume oxygen and provide energy for cellular activities. To investigate the mitochondrial mechanisms underlying adaptation to extreme oxygen conditions, we generated Drosophila strains that could survive in low- or high-oxygen environments (LOF or HOF, respectively, examined their mitochondria at the ultrastructural level via transmission electron microscopy, studied the activity of their respiratory chain complexes, and quantitatively analyzed the protein abundance responses of the mitochondrial proteomes using Isobaric tag for relative and absolute quantitation (iTRAQ. A total of 718 proteins were identified with high confidence, and 55 and 75 mitochondrial proteins displayed significant differences in abundance in LOF and HOF, respectively, compared with the control flies. Importantly, these differentially expressed mitochondrial proteins are primarily involved in respiration, calcium regulation, the oxidative response, and mitochondrial protein translation. A correlation analysis of the changes in the levels of the mRNAs corresponding to differentially regulated mitochondrial proteins revealed two sets of proteins with different modes of regulation (transcriptional vs. post-transcriptional in both LOF and HOF. We believe that these findings will not only enhance our understanding of the mechanisms underlying adaptation to extreme oxygen conditions in Drosophila but also provide a clue in studying human disease induced by altered oxygen tension in tissues and cells.

  11. Spectroscopic Determination of Trace Contaminants in High Purity Oxygen

    Science.gov (United States)

    Hornung, Steven D.

    2011-01-01

    Oxygen used for extravehicular activities (EVA) must be free of contaminants because a difference in a few tenths of a percent of argon or nitrogen content can mean significant reduction in available EVA time. These inert gases build up in the extravehicular mobility unit because they are not metabolized or scrubbed from the atmosphere. Measurement of oxygen purity above 99.5% is problematic, and currently only complex instruments such as gas chromatographs or mass spectrometers are used for these determinations. Because liquid oxygen boil-off from the space shuttle will no longer be available to supply oxygen for EVA use, other concepts are being developed to produce and validate high purity oxygen from cabin air aboard the International Space Station. A prototype optical emission technique capable of detecting argon and nitrogen below 0.1% in oxygen was developed at White Sands Test Facility. This instrument uses a glow discharge in reduced pressure gas to produce atomic emission from the species present. Because the atomic emission lines from oxygen, nitrogen, and argon are discrete and in many cases well-separated, trace amounts of argon and nitrogen can be detected in the ultraviolet and visible spectrum. This is a straightforward, direct measurement of the target contaminants and may lend itself to a device capable of on-orbit verification of oxygen purity. System design and optimized measurement parameters are presented.

  12. Validation of the protoporphyrin IX-triplet state lifetime technique for mitochondrial oxygen measurements in the skin

    NARCIS (Netherlands)

    F.A. Harms (Floor A.); S.I.A. Bodmer (Sander I. A.); N.J.H. Raat (Nicolaas); R.J. Stolker (Robert); E.G. Mik (Egbert)

    2012-01-01

    textabstractMitochondrial oxygen tension can be measured in vivo by means of oxygen-dependent quenching of delayed fluorescence of protoporphyrin IX (PpIX). Here we demonstrate that mitochondrial PO2 (mitoPO2) can be measured in the skin of a rat after topical application of the PpIX precursor

  13. Effects of the kinematic viscosity and surface tension on the bubble take-off period in a catalase-hydrogen peroxide system.

    Science.gov (United States)

    Sasaki, Satoshi; Iida, Yoshinori

    2009-06-01

    The effect of kinematic viscosity and surface tension of the solution was investigated by adding catalase, glucose oxidase, or glucose on the bubble movement in a catalase-hydrogen peroxide system. The kinematic viscosity was measured using a Cannon-Fenske kinematic viscometer. The surface tension of the solution was measured by the Wilhelmy method using a self-made apparatus. The effects of the hole diameter/cell wall thickness, catalase concentration, glucose concentration, and glucose oxidase concentration on the kinematic viscosity, surface tension, and bubble take-off period were investigated. With our system, the effects of the changes in the solution materiality on the bubble take-off period were proven to be very small in comparison to the change in the oxygen-producing rate.

  14. Automated wireless monitoring system for cable tension using smart sensors

    Science.gov (United States)

    Sim, Sung-Han; Li, Jian; Jo, Hongki; Park, Jongwoong; Cho, Soojin; Spencer, Billie F.; Yun, Chung-Bang

    2013-04-01

    Cables are critical load carrying members of cable-stayed bridges; monitoring tension forces of the cables provides valuable information for SHM of the cable-stayed bridges. Monitoring systems for the cable tension can be efficiently realized using wireless smart sensors in conjunction with vibration-based cable tension estimation approaches. This study develops an automated cable tension monitoring system using MEMSIC's Imote2 smart sensors. An embedded data processing strategy is implemented on the Imote2-based wireless sensor network to calculate cable tensions using a vibration-based method, significantly reducing the wireless data transmission and associated power consumption. The autonomous operation of the monitoring system is achieved by AutoMonitor, a high-level coordinator application provided by the Illinois SHM Project Services Toolsuite. The monitoring system also features power harvesting enabled by solar panels attached to each sensor node and AutoMonitor for charging control. The proposed wireless system has been deployed on the Jindo Bridge, a cable-stayed bridge located in South Korea. Tension forces are autonomously monitored for 12 cables in the east, land side of the bridge, proving the validity and potential of the presented tension monitoring system for real-world applications.

  15. Engineering High-Energy Interfacial Structures for High-Performance Oxygen-Involving Electrocatalysis.

    Science.gov (United States)

    Guo, Chunxian; Zheng, Yao; Ran, Jingrun; Xie, Fangxi; Jaroniec, Mietek; Qiao, Shi-Zhang

    2017-07-10

    Engineering high-energy interfacial structures for high-performance electrocatalysis is achieved by chemical coupling of active CoO nanoclusters and high-index facet Mn 3 O 4 nano-octahedrons (hi-Mn 3 O 4 ). A thorough characterization, including synchrotron-based near edge X-ray absorption fine structure, reveals that strong interactions between both components promote the formation of high-energy interfacial Mn-O-Co species and high oxidation state CoO, from which electrons are drawn by Mn III -O present in hi-Mn 3 O 4 . The CoO/hi-Mn 3 O 4 demonstrates an excellent catalytic performance over the conventional metal oxide-based electrocatalysts, which is reflected by 1.2 times higher oxygen evolution reaction (OER) activity than that of Ru/C and a comparable oxygen reduction reaction (ORR) activity to that of Pt/C as well as a better stability than that of Ru/C (95 % vs. 81 % retained OER activity) and Pt/C (92 % vs. 78 % retained ORR activity after 10 h running) in alkaline electrolyte. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Effect of oxygen supplementation in a hatchery at high altitude and ...

    African Journals Online (AJOL)

    The objective of this study was to investigate the effect of oxygen supplementation on broiler eggs in a hatchery at high altitude on the growth performance and ascites syndrome of broilers reared at low altitude. The treatment groups were low altitude with no oxygen supplemented in the hatchery (LA-NOX); high altitude with ...

  17. General definition of gravitational tension

    International Nuclear Information System (INIS)

    Harmark, T.; Obers, N.A.

    2004-01-01

    In this note we give a general definition of the gravitational tension in a given asymptotically translationally-invariant spatial direction of a space-time. The tension is defined via the extrinsic curvature in analogy with the Hawking-Horowitz definition of energy. We show the consistency with the ADM tension formulas for asymptotically-flat space-times, in particular for Kaluza-Klein black hole solutions. Moreover, we apply the general tension formula to near-extremal branes, constituting a check for non-asymptotically flat space-times. (author)

  18. Structural design significance of tension-tension fatigue data on composites

    Science.gov (United States)

    Grimes, G. C.

    1977-01-01

    Constant cycle tension-tension fatigue and related static tension data have been generated on six single composite material/orientation combinations and twenty-one hybrid composite material/orientation combinations. Anomalies are related to the temperature rise and stopped interval creep, whereas endurance limit stresses (runouts) are associated with static proportional limit values, when they occur, and internal damage. The significance of these room temperature-dry data on the design allowables and weight of aerodynamic structueres is discussed. Such structures are helicopter rotor blades and wing and horizontal stabilizer lower surfaces. Typical criteria for turning these data into preliminary allowables are shown, as are examples of such allowables developed from the data. These values are then compared to those that might be used if the structures were made of metal.

  19. Tension type headache

    Directory of Open Access Journals (Sweden)

    Debashish Chowdhury

    2012-01-01

    Full Text Available Tension type headaches are common in clinical practice. Earlier known by various names, the diagnosis has had psychological connotations. Recent evidence has helped clarify the neurobiological basis and the disorder is increasingly considered more in the preview of neurologists. The classification, clinical features, differential diagnosis and treatment of tension type headache are discussed in this paper.

  20. Prediction of tension-type headache risk in adolescents

    Directory of Open Access Journals (Sweden)

    K. A. Stepanchenko

    2016-08-01

    Full Text Available Tension-type headache is the actual problem of adolescent neurology, which is associated with the prevalence of the disease, the tendency of the disease to the chronic course and a negative impact on performance in education, work capacity and quality of patients’ life. The aim. To develop a method for prediction of tension-type headache occurrence in adolescents. Materials and methods. 2342 adolescent boys and girls at the age of 13-17 years in schools of Kharkiv were examined. We used questionnaire to identify the headache. A group of adolescents with tension-type headache - 1430 people (61.1% was selected. The control group included 246 healthy adolescents. Possible risk factors for tension-type headache formation were divided into 4 groups: genetic, biomedical, psychosocial and social. Mathematical prediction of tension-type headache risk in adolescents was performed using the method of intensive indicators normalization of E.N. Shigan, which was based on probabilistic Bayesian’s method. The result was presented in the form of prognostic coefficients. Results. The most informative risk factors for tension-type headache development were the diseases, from which the teenager suffered after 1 year (sleep disorders, gastrointestinal diseases, autonomic disorders in the family history, traumatic brain injury, physical inactivity, poor adaptation of the patient in the kindergarten and school, stresses. Diagnostic scale has been developed to predict the risk of tension-type headache. It includes 23 prognostic factors with their gradation and meaning of integrated risk indicator, depending on individual factor strength influence. The risk of tension-type headache development ranged from 25,27 to 81,43 values of prognostic coefficient (low probability (25,27-43,99, the average probability (43,99-62,71 and high probability (62,71- 81,43. Conclusion. The study of tension-type headache risk factors, which were obtained by using an assessed and

  1. Tumour oxygen dynamics measured simultaneously by near-infrared spectroscopy and 19F magnetic resonance imaging in rats

    International Nuclear Information System (INIS)

    Xia Mengna; Kodibagkar, Vikram; Liu Hanli; Mason, Ralph P

    2006-01-01

    Simultaneous near-infrared spectroscopy (NIRS) and magnetic resonance imaging (MRI) were used to investigate the correlation between tumour vascular oxygenation and tissue oxygen tension dynamics in rat breast 13762NF tumours with respect to hyperoxic gas breathing. NIRS directly detected global variations in the oxygenated haemoglobin concentration (Δ[HbO 2 ]) within tumours and oxygen tension (pO 2 ) maps were achieved using 19 F MRI of the reporter molecule hexafluorobenzene. Multiple correlations were examined between rates and magnitudes of vascular (Δ[HbO 2 ]) and tissue (pO 2 ) responses. Significant correlations were found between response to oxygen and carbogen breathing using either modality. Comparison of results for the two methods showed a correlation between the vascular perfusion rate ratio and the mean pO 2 values (R 2 > 0.7). The initial rates of increase of Δ[HbO 2 ] and the slope of dynamic pO 2 response, d(pO 2 )/dt, of well-oxygenated voxels in response to hyperoxic challenge were also correlated. These results demonstrate the feasibility of simultaneous measurements using NIRS and MRI. As expected, the rate of pO 2 response to oxygen is primarily dependent upon the well perfused rather than poorly perfused vasculature

  2. Oxygen binding properties, capillary densities and heart weights in high altitude camelids.

    Science.gov (United States)

    Jürgens, K D; Pietschmann, M; Yamaguchi, K; Kleinschmidt, T

    1988-01-01

    The oxygen binding properties of the blood of the camelid species vicuna, llama, alpaca and dromedary camel were measured and evaluated with respect to interspecific differences. The highest blood oxygen affinity, not only among camelids but of all mammals investigated so far, was found in the vicuna (P50 = 17.6 Torr compared to 20.3-21.6 Torr in the other species). Low hematocrits (23-34%) and small red blood cells (21-30 microns 3) are common features of all camelids, but the lowest values are found in the Lama species. Capillary densities were determined in heart and soleus muscle of vicuna and llama. Again, the vicuna shows exceptional values (3720 cap/mm2 on average in the heart) for a mammal of this body size. Finally, heart weight as percent of body weight is higher in the vicuna (0.7-0.9%) than in the other camelids studied (0.5-0.7%). The possibility that these parameters, measured in New World tylopodes at sea level, are not likely to change considerably with transfer to high altitude, is discussed. In the vicuna, a unique combination of the following features seems to be responsible for an outstanding physical capability at high altitude: saturation of blood with oxygen in the lung is favored by a high blood oxygen affinity, oxygen supply being facilitated by low diffusion distances in the muscle tissue. Loading, as well as unloading, of oxygen is improved by a relatively high oxygen transfer conductance of the red blood cells, which is due to their small size and which compensates the negative effect of a low hematocrit on the oxygen conductance of blood.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Transcriptional and metabolic response of recombinant Escherichia coli to spatial dissolved oxygen tension gradients simulated in a scale-down system.

    Science.gov (United States)

    Lara, Alvaro R; Leal, Lidia; Flores, Noemí; Gosset, Guillermo; Bolívar, Francisco; Ramírez, Octavio T

    2006-02-05

    Escherichia coli, expressing recombinant green fluorescent protein (GFP), was subjected to dissolved oxygen tension (DOT) oscillations in a two-compartment system for simulating gradients that can occur in large-scale bioreactors. Cells were continuously circulated between the anaerobic (0% DOT) and aerobic (10% DOT) vessels of the scale-down system to mimic an overall circulation time of 50 s, and a mean residence time in the anaerobic and aerobic compartments of 33 and 17 s, respectively. Transcription levels of mixed acid fermentation genes (ldhA, poxB, frdD, ackA, adhE, pflD, and fdhF), measured by quantitative RT-PCR, increased between 1.5- to over 6-fold under oscillatory DOT compared to aerobic cultures (constant 10% DOT). In addition, the transcription level of fumB increased whereas it decreased for sucA and sucB, suggesting that the tricarboxylic acid cycle was functioning as two open branches. Gene transcription levels revealed that cytrochrome bd, which has higher affinity to oxygen but lower energy efficiency, was preferred over cytochrome bO3 in oscillatory DOT cultures. Post-transcriptional processing limited heterologous protein production in the scale-down system, as inferred from similar gfp transcription but 19% lower GFP concentration compared to aerobic cultures. Simulated DOT gradients also affected the transcription of genes of the glyoxylate shunt (aceA), of global regulators of aerobic and anaerobic metabolism (fnr, arcA, and arcB), and other relevant genes (luxS, sodA, fumA, and sdhB). Transcriptional changes explained the observed alterations in overall stoichiometric and kinetic parameters, and production of ethanol and organic acids. Differences in transcription levels between aerobic and anaerobic compartments were also observed, indicating that E. coli can respond very fast to intermittent DOT conditions. The transcriptional responses of E. coli to DOT gradients reported here are useful for establishing rational scale-up criteria and

  4. On relation between the quark-gluon bag surface tension and the colour tube string tension

    International Nuclear Information System (INIS)

    Bugaev, K.A.; Zinovjev, G.M.

    2010-01-01

    We revisit the bag phenomenology of deconfining phase transition aiming to replenish it by introducing systematically the bag surface tension. Comparing the free energies of such bags and the strings confining the static quark-antiquark pair, we express the string tension in terms of the bag surface tension and the bulk pressure in order to estimate the bag characteristics using the lattice QCD (LQCD) data. Our analysis of the bag entropy density demonstrates that the surface tension coefficient is amazingly negative at the cross-over (continuous transition). The approach developed allows us to naturally account for an origin of a pronounced maximum (observed in the LQCD studies) in the behaviour of heavy quark-antiquark pair entropy. The vicinity of the (tri-)critical endpoint is also analyzed to clarify the meaning of vanishing surface tension coefficient.

  5. Inverse Regulation of Early and Late Chondrogenic Differentiation by Oxygen Tension Provides Cues for Stem Cell-Based Cartilage Tissue Engineering

    Directory of Open Access Journals (Sweden)

    Sophie Portron

    2015-01-01

    Full Text Available Background/Aims: Multipotent stem/stromal cells (MSC are considered promising for cartilage tissue engineering. However, chondrogenic differentiation of MSC can ultimately lead to the formation of hypertrophic chondrocytes responsible for the calcification of cartilage. To prevent the production of this calcified matrix at the articular site, the late hypertrophic differentiation of MSCs must be carefully controlled. Given that articular cartilage is avascular, we hypothesized that in addition to its stimulatory role in the early differentiation of chondrogenic cells, hypoxia may prevent their late hypertrophic conversion. Methods: Early and late chondrogenic differentiation were evaluated using human adipose MSC and murine ATDC5 cells cultured under either normoxic (21%O2 or hypoxic (5%O2 conditions. To investigate the effect of hypoxia on late chondrogenic differentiation, the transcriptional activity of hypoxia-inducible factor-1alpha (HIF-1α and HIF-2α were evaluated using the NoShift DNA-binding assay and through modulation of their activity (chemical inhibitor, RNA interference. Results: Our data demonstrate that low oxygen tension not only stimulates the early chondrogenic commitment of two complementary models of chondrogenic cells, but also inhibits their hypertrophic differentiation. Conclusion: These results suggest that hypoxia can be used as an instrumental tool to prevent the formation of a calcified matrix in MSC-based cartilage tissue engineering.

  6. Surface tension modelling of liquid Cd-Sn-Zn alloys

    Science.gov (United States)

    Fima, Przemyslaw; Novakovic, Rada

    2018-06-01

    The thermodynamic model in conjunction with Butler equation and the geometric models were used for the surface tension calculation of Cd-Sn-Zn liquid alloys. Good agreement was found between the experimental data for limiting binaries and model calculations performed with Butler model. In the case of ternary alloys, the surface tension variation with Cd content is better reproduced in the case of alloys lying on vertical sections defined by high Sn to Zn molar fraction ratio. The calculated surface tension is in relatively good agreement with the available experimental data. In addition, the surface segregation of liquid ternary Cd-Sn-Zn and constituent binaries has also been calculated.

  7. High performance platinum single atom electrocatalyst for oxygen reduction reaction

    Science.gov (United States)

    Liu, Jing; Jiao, Menggai; Lu, Lanlu; Barkholtz, Heather M.; Li, Yuping; Wang, Ying; Jiang, Luhua; Wu, Zhijian; Liu, Di-Jia; Zhuang, Lin; Ma, Chao; Zeng, Jie; Zhang, Bingsen; Su, Dangsheng; Song, Ping; Xing, Wei; Xu, Weilin; Wang, Ying; Jiang, Zheng; Sun, Gongquan

    2017-07-01

    For the large-scale sustainable implementation of polymer electrolyte membrane fuel cells in vehicles, high-performance electrocatalysts with low platinum consumption are desirable for use as cathode material during the oxygen reduction reaction in fuel cells. Here we report a carbon black-supported cost-effective, efficient and durable platinum single-atom electrocatalyst with carbon monoxide/methanol tolerance for the cathodic oxygen reduction reaction. The acidic single-cell with such a catalyst as cathode delivers high performance, with power density up to 680 mW cm-2 at 80 °C with a low platinum loading of 0.09 mgPt cm-2, corresponding to a platinum utilization of 0.13 gPt kW-1 in the fuel cell. Good fuel cell durability is also observed. Theoretical calculations reveal that the main effective sites on such platinum single-atom electrocatalysts are single-pyridinic-nitrogen-atom-anchored single-platinum-atom centres, which are tolerant to carbon monoxide/methanol, but highly active for the oxygen reduction reaction.

  8. The law of corresponding states and surface tension of metals

    International Nuclear Information System (INIS)

    Digilov, R.

    2001-01-01

    Full Text: Surface tension of liquid metals is one of fundamental and most important quantities in theory and practice of material processing and its temperature dependence leads to the well-known Marangoni convection. Although currently methods are sufficiently precise to measure the surface tension, there are uncertainties in experimental data and its temperature dependence mainly due to impurity, which even a trace of it strongly affects the results of measurements. The theoretical treatment from the first principles is unwieldy and not always permits one to calculate the surface tension with certainty. Another active research field deals with empirical correlation between the surface tension and bulk thermodynamic properties, which we interpret as a simple consequence of the law of corresponding states. In order to relate the surface tension and to bulk properties of liquid metals the reduced formula is derived by scaling with the melting point T m (0) at p = 0 and atomic volume Ω 0 2/3 at T = 0 K as macroscopic parameters for scaling ε and a characterizing the interatomic potential in metals. The reduced surface tension and the reduced surface entropy obtained in high temperature limit are discussed and compared with the experiment. The reduced temperature coefficient of the surface tension found is a universal constant for the metals of the same structure. It is shown that pressure dependence of the surface tension, so called baric coefficient of the surface tension, can be described by pressure dependence of scaling parameters T m (p) and Ω 0 (p). (author)

  9. Tensioned Fabric Structures with Surface in the Form of Chen-Gackstatter

    Directory of Open Access Journals (Sweden)

    Yee Hooi Min

    2016-01-01

    Full Text Available Form-finding has to be carried out for tensioned fabric structure in order to determine the initial equilibrium shape under prescribed support condition and prestress pattern. Tensioned fabric structures are normally designed to be in the form of equal tensioned surface. Tensioned fabric structure is highly suited to be used for realizing surfaces of complex or new forms. However, research study on a new form as a tensioned fabric structure has not attracted much attention. Another source of inspiration minimal surface which could be adopted as form for tensioned fabric structure is very crucial. The aim of this study is to propose initial equilibrium shape of tensioned fabric structures in the form of Chen-Gackstatter. Computational form-finding using nonlinear analysis method is used to determine the Chen-Gackstatter form of uniformly stressed surfaces. A tensioned fabric structure must curve equally in opposite directions to give the resulting surface a three dimensional stability. In an anticlastic doubly curved surface, the sum of all positive and all negative curvatures is zero. This study provides an alternative choice for structural designer to consider the Chen-Gackstatter applied in tensioned fabric structures. The results on factors affecting initial equilibrium shape can serve as a reference for proper selection of surface parameter for achieving a structurally viable surface.

  10. Clinical studies with high flow nasal cannula oxygen delivery in 2015

    Directory of Open Access Journals (Sweden)

    David Sotello

    2016-04-01

    Full Text Available HFNC devices can provide humidified oxygen at high flow rates with high FiO2s.  This method of oxygen delivery appears to be more comfortable than using noninvasive ventilation, and it does improve oxygenation, reduce respiratory rates, and reduce the sense of dyspnea.  This modality has been studied most in patients with acute hypoxemic respiratory failure. The study reported by Frat et al provides good evidence that patients with moderate to severe respiratory failure (PaO2/FiO2 < 200 may benefit the most. The more complex the patient’s underlying medical problems are the more likely HFNC therapy to fail

  11. HIGH PERFORMANCE CERIA BASED OXYGEN MEMBRANE

    DEFF Research Database (Denmark)

    2014-01-01

    The invention describes a new class of highly stable mixed conducting materials based on acceptor doped cerium oxide (CeO2-8 ) in which the limiting electronic conductivity is significantly enhanced by co-doping with a second element or co- dopant, such as Nb, W and Zn, so that cerium and the co......-dopant have an ionic size ratio between 0.5 and 1. These materials can thereby improve the performance and extend the range of operating conditions of oxygen permeation membranes (OPM) for different high temperature membrane reactor applications. The invention also relates to the manufacturing of supported...

  12. Characterization of hemodynamics and oxygenation in the renal cortex of rats

    Science.gov (United States)

    Grosenick, Dirk; Wabnitz, Heidrun; Macdonald, Rainer; Niendorf, Thoralf; Cantow, Kathleen; Flemming, Bert; Arakelyan, Karen; Seeliger, Erdmann

    2015-03-01

    We have performed a pre-clinical study on 13 rats to investigate the potential of near-infrared spectroscopy for quantification of hemoglobin concentration and oxygen saturation of hemoglobin in the renal cortex of small animals. These measurements were combined with laser-Doppler fluxmetry and a fluorescence quenching technique for quantification of tissue oxygen tension. Hemoglobin concentration and oxygen saturation were determined from experimental data by a Monte Carlo model. The methods were applied to investigate and compare temporal changes during several types of interventions such as arterial and venous occlusions, as well as hyperoxia, hypoxia and hypercapnia induced by different mixtures of the inspired gas.

  13. Soft-tissue tension total knee arthroplasty.

    Science.gov (United States)

    Asano, Hiroshi; Hoshino, Akiho; Wilton, Tim J

    2004-08-01

    It is far from clear how best to define the proper strength of soft-tissue tensioning in total knee arthroplasty (TKA). We attached a torque driver to the Monogram balancer/tensor device and measured soft-tissue tension in full extension and 90 degrees flexion during TKA. In our surgical procedure, when we felt proper soft-tissue tension was being applied, the mean distraction force was noted to be 126N in extension and 121N in flexion. There was no significant correlation between soft-tissue tension and the postoperative flexion angle finally achieved. To the best of our knowledge, this is the first study to assess the actual distraction forces in relation to soft-tissue tension in TKA. Further study may reveal the most appropriate forces to achieve proper soft-tissue tension in the wide variety of circumstances presenting at knee arthroplasty.

  14. Cutaneous respirometry by dynamic measurement of mitochondrial oxygen tension for monitoring mitochondrial function in vivo.

    Science.gov (United States)

    Harms, Floor A; Voorbeijtel, Wilhelmina J; Bodmer, Sander I A; Raat, Nicolaas J H; Mik, Egbert G

    2013-09-01

    Progress in diagnosis and treatment of mitochondrial dysfunction in chronic and acute disease could greatly benefit from techniques for monitoring of mitochondrial function in vivo. In this study we demonstrate the feasibility of in vivo respirometry in skin. Mitochondrial oxygen measurements by means of oxygen-dependent delayed fluorescence of protoporphyrin IX are shown to provide a robust basis for measurement of local oxygen disappearance rate (ODR). The fundamental principles behind the technology are described, together with an analysis method for retrievel of respirometry data. The feasibility and reproducibility of this clinically useful approach are demonstrated in a series of rats. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Effects of Dissolved Oxygen Concentration and Iron Addition on Immediate-early Gene Expression of Magnetospirillum gryphiswaldense MSR-1

    DEFF Research Database (Denmark)

    Zhuang, Shiwen; Anyaogu, Diana Chinyere; Kasama, Takeshi

    2017-01-01

    in cultures at 0.5% O2 compared to those at higher oxygen tensions. Moreover, expression of katG (catalase-peroxidase gene) and feoB2 (ferrous transport protein B2 gene) was reduced markedly by iron addition, regardless of oxygen conditions. The data provides a greater understanding of molecular response...

  16. Study on Oxygen Supply Standard for Physical Health of Construction Personnel of High-Altitude Tunnels

    Directory of Open Access Journals (Sweden)

    Chun Guo

    2015-12-01

    Full Text Available The low atmospheric pressure and low oxygen content in high-altitude environment have great impacts on the functions of human body. Especially for the personnel engaged in complicated physical labor such as tunnel construction, high altitude can cause a series of adverse physiological reactions, which may result in multiple high-altitude diseases and even death in severe cases. Artificial oxygen supply is required to ensure health and safety of construction personnel in hypoxic environments. However, there are no provisions for oxygen supply standard for tunnel construction personnel in high-altitude areas in current tunnel construction specifications. As a result, this paper has theoretically studied the impacts of high-altitude environment on human bodies, analyzed the relationship between labor intensity and oxygen consumption in high-altitude areas and determined the critical oxygen-supply altitude values for tunnel construction based on two different standard evaluation systems, i.e., variation of air density and equivalent PIO2. In addition, it has finally determined the oxygen supply standard for construction personnel in high-altitude areas based on the relationship between construction labor intensity and oxygen consumption.

  17. [Effect of hemodilution with 10% hydroxyethyl starch solution (MW 200,000/9.5) on the flow properties of blood, arterial blood gases and conjunctival oxygen partial pressure in patients with cerebral infarct].

    Science.gov (United States)

    Staedt, U; Hütt, M; Herrmann, B; Seufzer, U; Leweling, H

    1989-06-01

    Hemorheological parameters, arterial blood gases and conjunctival oxygen tension were measured in 15 patients with acute ischemic stroke and compared with values obtained in an age matched reference group. Since the conjunctival capillary bed is perfused by the ophthalmic artery, it reflects the oxygen delivery to the areas supplied by the internal carotid artery. Measurements of conjunctival oxygen tension are simple and safe. Patients with acute ischemic stroke showed a lowered conjunctival oxygen tension; this holds true especially to the ipsilateral side, i.e. the side where the attack occurred, and to a lesser extent to the other side. By contrast, the ratio of arterial/conjunctival pO2 was disturbed only on the ipsilateral side. Furthermore, these patients had pathologically elevated values for red cell aggregation, whole blood and plasma viscosity. After infusing 500 ml 10% middle-molecular-weight hydroxyethyl starch (10% HAES-steril) and phlebotomy (250 ml) blood fluidity was normalized, although the hematokrit was only slightly reduced. Arterial pO2 improved slightly while pCO2 remained unchanged. Conjunctival oxygen tension improved by 30% on the ipsilateral and by 10% on the contralateral side, the ipsilateral values always remaining significantly lower. The ratio conjunctival/arterial pO2 raised only on the ipsilateral side where it was below the reference range before hemodilution. In addition to the well known improvement of blood fluidity and augmentation of cerebral blood flow following hemodilution in patients with acute ischemic stroke, there seems to be an increase in oxygen supply in the territories of both internal carotid arteries, especially on the ipsilateral side as indicated by the values of conjunctival oxygen tension and the ratio of conjunctival to arterial pO2.

  18. Spontaneous tension haemopneumothorax

    OpenAIRE

    Patterson, Benjamin Oliver; Itam, Sarah; Probst, Fey

    2008-01-01

    Abstract We present a patient with sudden onset progressive shortness of breath and no history of trauma, who rapidly became haemodynamically compromised with a pneumothorax and pleural effusion seen on chest radiograph. He was treated for spontaneous tension pneumothorax but this was soon revealed to be a tension haemopneumothorax. He underwent urgent thoracotomy after persistent bleeding to explore an apical vascular abnormality seen on CT scanning. To our knowledge this is the first such c...

  19. Clinical research on high oxygen permeable contact lens used after photorefractive keratectomy surgery

    Directory of Open Access Journals (Sweden)

    Hao-Jiang Yang

    2013-07-01

    Full Text Available AIM: To evaluate the outcome of high oxygen permeable contact lens used after photorefractive keratectomy(PRKsurgery.METHODS: Totally 95 patients(190 eyesafter PRK were included. Patients were randomly assigned to wear high oxygen permeable contact lens in one eye and normal lens in the fellow eye after surgery. The subjective symptoms and corneal epithelial status after PRK were evaluated. Uncorrected visual acuity(UCVAand haze were assessed at 6 months after PRK.RESULTS: Complaints of blurred vision, pain and photophobia were statistically more among the normal lens group than high oxygen permeable contact lens group(PPP=0.35. There was no difference in UCVA and haze 6 months after surgery(P=0.55. CONCLUSION: High oxygen permeable contact lens can significantly produce less the corneal irritated symptoms, reduce the discomfort feeling and promote healing of corneal epithelium after PRK.

  20. Experimental and analytical study of oxygen depletion in stirred cell suspensions

    International Nuclear Information System (INIS)

    Whillans, D.W.; Rauth, A.M.

    1980-01-01

    The determination and maintenance of constant low but non-zero levels of oxygen is critical in the study of the radiation chemical interactions of nitroimidazoles in mammalian cells in vitro. As well, many of these chemicals have increased toxicity toward hypoxic compared to aerobic cells, although absolute hypoxia probably is not required. Both of these phenomena must be investigated in systems where significant consumption of oxygen takes place, either through radiation depletion or by cellular metabolism. In this paper an analysis has been made of the form of oxygen depletion in stirred cell suspensions with overlying gas phase, and it has been found to conform to the relationship (C[t] - C/sub infinity/) = (C[0] - C/sub infinity/) exp(-k 1 t), where C/sub infinity/ = C/sub g/ - R/k 1 . Here C[t] is the oxygen tension throughout the solution; C/sub g/, the equivalent level in the overlying gas phase; R (concentration units per sec), the depletion rate; k 1 (sec/sup -1/), a physical constant independent of oxygen concentration and depletion rate; and C/sub infinity/, the oxygen level in solution approached at long times. This relationship has been confirmed in detail using a Clark-type oxygen sensor and a high-stability amplifier design due to Koch. Since oxygen levels down to a few hundred parts per million can be determined with accuracy, it has been possible to measure precisely the oxygen levels present in our experimental systems. Implications of these results for the interpretation of data obtained in stirred cell suspension with overlying gas phase under conditions of consumption are discussed

  1. Tension headache.

    Science.gov (United States)

    Ziegler, D K

    1978-05-01

    Headache is an extremely common symptom, and many headaches undoubtedly have a relationship to stressful situations. The clear definition, however, of a "tension headache" complex and its differentiation from migraine in some patients is difficult. The problems are in the identification of a specific headache pattern induced by stress or "tension" and the relationship of the symptom to involuntary contraction of neck and scalp muscles. Treatment consists of analgesics and occasionally mild tranquilizers. Psychotherapy consists of reassurance and often other supportive measures, including modification of life styles. Various feedback techniques have been reported of value, but their superiority to suggestion and hypnosis is still problematic.

  2. Structure of Greyhound hemoglobin: origin of high oxygen affinity.

    Science.gov (United States)

    Bhatt, Veer S; Zaldívar-López, Sara; Harris, David R; Couto, C Guillermo; Wang, Peng G; Palmer, Andre F

    2011-05-01

    This study presents the crystal structure of Greyhound hemoglobin (GrHb) determined to 1.9 Å resolution. GrHb was found to crystallize with an α₁β₁ dimer in the asymmetric unit and belongs to the R2 state. Oxygen-affinity measurements combined with the fact that GrHb crystallizes in the R2 state despite the high-salt conditions used for crystallization strongly indicate that GrHb can serve as a model high-oxygen-affinity hemoglobin (Hb) for higher mammals, especially humans. Structural analysis of GrHb and its comparison with the R2-state of human Hb revealed several regions that can potentially contribute to the high oxygen affinity of GrHb and serve to rationalize the additional stability of the R2-state of GrHb. A previously well studied hydrophobic cluster of bar-headed goose Hb near α119 was also incorporated in the comparison between GrHb and human Hb. Finally, a structural comparison with generic dog Hb and maned wolf Hb was conducted, revealing that in contrast to GrHb these structures belong to the R state of Hb and raising the intriguing possibility of an additional allosteric factor co-purifying with GrHb that can modulate its quaternary structure.

  3. Adult and newborn rat inner retinal oxygenation during carbogen and 100% oxygen breathing. Comparison using magnetic resonance imaging delta Po2 mapping.

    Science.gov (United States)

    Berkowitz, B A

    1996-09-01

    To test the hypothesis that breathing carbogen (95% O2-5% CO2) oxygenates the inner retina better than breathing 100% oxygen using an magnetic resonance imaging (MRI) method that noninvasively measures inner retinal oxygenation in normal adult and newborn rats. Urethane-anesthetized adult and newborn (day 18) rats were studied. Sequential images were acquired in room air combined with either 100% oxygen or carbogen breathing. Normalized vitreous signal intensity changes were converted to oxygen tension changes (delta PO2) either on a pixel-by-pixel basis or in specific regions of interest. Systemic levels of hyperoxia during carbogen or 100% oxygen breathing were not significantly different (P > 0.05). In the adult rat, a significant difference (P = 0.017) was found in the preretinal vitreous delta PO2 during the breathing of either carbogen (130 +/- 9 mm Hg, mean +/- SEM; n = 5) or 100% oxygen (88 +/- 16 mm Hg; n = 5). Agreement was found between the MRI-determined delta PO2 values and literature oxygen microelectrodes data. In the newborn rat, significant differences (P delta PO2 were found during carbogen (164 +/- 23 mm Hg; n = 3) and oxygen breathing (91 +/- 8 mm Hg; n = 3). MRI delta PO2 mapping demonstrated for the first time that in the normal adult and newborn rat eye, carbogen breathing oxygenates the inner retina better than 100% oxygen breathing.

  4. Tensions in Distributed Leadership

    Science.gov (United States)

    Ho, Jeanne; Ng, David

    2017-01-01

    Purpose: This article proposes the utility of using activity theory as an analytical lens to examine the theoretical construct of distributed leadership, specifically to illuminate tensions encountered by leaders and how they resolved these tensions. Research Method: The study adopted the naturalistic inquiry approach of a case study of an…

  5. High Performance Electrocatalytic Reaction of Hydrogen and Oxygen on Ruthenium Nanoclusters

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Ruquan; Liu, Yuanyue; Peng, Zhiwei; Wang, Tuo; Jalilov, Almaz S.; Yakobson, Boris I.; Wei, Su-Huai; Tour, James M.

    2017-01-18

    The development of catalytic materials for the hydrogen oxidation, hydrogen evolution, oxygen reduction or oxygen evolution reactions with high reaction rates and low overpotentials are key goals for the development of renewable energy. We report here Ru(0) nanoclusters supported on nitrogen-doped graphene as high-performance multifunctional catalysts for the hydrogen evolution reaction (HER) and oxygen reduction reaction (ORR), showing activities similar to that of commercial Pt/C in alkaline solution. For HER performance in alkaline media, sample Ru/NG-750 reaches 10 mA cm-2 at an overpotential of 8 mV with a Tafel slope of 30 mV dec-1. The high HER performance in alkaline solution is advantageous because most catalysts for ORR and oxygen evolution reaction (OER) also prefer alkaline solution environment whereas degrade in acidic electrolytes. For ORR performance, Ru/NG effectively catalyzes the conversion of O2 into OH- via a 4e process at a current density comparable to that of Pt/C. The unusual catalytic activities of Ru(0) nanoclusters reported here are important discoveries for the advancement of renewable energy conversion reactions.

  6. Methodology for the analysis of self-tensioned wooden structural floors

    Directory of Open Access Journals (Sweden)

    F. Suárez-Riestra

    2017-09-01

    Full Text Available It is described a self-tensioning system constituted by a force multiplying device which, attached to the supports of the ends of the structural element, is able to convert the vertical resultant from the gravitatonial actions into an effective tensioning action, through the movement that was induced by a set of rods. The self-tensioning system is able to offer a high performance, thanks to the beneficial effect of the opposite deflection generated by the tensioning, in proportion to the increasing of the gravitational action. This allows to design long-span timber ribbed floors using reduced depths. The complexity of calculation due to the non-linearity of the system can be obviated with the methodology of analysis developed in the article. In order to illustrate the advantages of the self-tensioning system and the methodology of analysis which were developed, six cases of ribbed floors have been analysed, with spans of 9, 12 and 15 m and variable using loads of 3,00 kN/m2 and 5,00 kN/m2.

  7. High Pressure Electrochemical Oxygen Generation for ISS, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Giner, Inc. has developed an advanced high pressure electrochemical oxygen concentrator (EOC) that offers a simple alternative to the use of pressure swing...

  8. Breakdown of highly excited oxygen in a DC electric field

    International Nuclear Information System (INIS)

    Vagin, N.P.; Ionin, A.A.; Klimachev, Yu.M.; Sinitsin, D.V.; Yuryshev, N.N.; Deryugin, A.A.; Kochetov, I.V.; Napartovich, A.P.

    2000-01-01

    The breakdown of oxygen in a dc electric field is studied. A high concentration of oxygen molecules in the a 1 Δ g excited state is obtained in a purely chemical reactor. A decrease in the breakdown voltage at degrees of excitation exceeding 50% is observed. The theoretical decrement in the breakdown voltage obtained by solving the Boltzmann equation is in good agreement with the experimental data

  9. Tension pneumocephalus: Mount Fuji sign

    Directory of Open Access Journals (Sweden)

    Pulastya Sanyal

    2015-01-01

    Full Text Available A 13-year-old male was operated for a space occupying lesion in the brain. A noncontrast computed tomography scan done in the late postoperative period showed massive subdural air collection causing compression of bilateral frontal lobes with widening of interhemispheric fissure and the frontal lobes acquiring a peak like configuration - causing tension pneumocephalus-"Mount Fuji sign." Tension pneumocephalus occurs when air enters the extradural or intradural spaces in sufficient volume to exert a mass or pressure effect on the brain, leading to brain herniation. Tension pneumocephalus is a surgical emergency, which needs immediate intervention in the form of decompression of the cranial cavity by a burr hole or needle aspiration. The Mount Fuji sign differentiates tension pneumocephalus from pneumocephalus.

  10. Environmental oxygen tension regulates the energy metabolism and self-renewal of human embryonic stem cells.

    Science.gov (United States)

    Forristal, Catherine E; Christensen, David R; Chinnery, Fay E; Petruzzelli, Raffaella; Parry, Kate L; Sanchez-Elsner, Tilman; Houghton, Franchesca D

    2013-01-01

    Energy metabolism is intrinsic to cell viability but surprisingly has been little studied in human embryonic stem cells (hESCs). The current study aims to investigate the effect of environmental O2 tension on carbohydrate utilisation of hESCs. Highly pluripotent hESCs cultured at 5% O2 consumed significantly more glucose, less pyruvate and produced more lactate compared to those maintained at 20% O2. Moreover, hESCs cultured at atmospheric O2 levels expressed significantly less OCT4, SOX2 and NANOG than those maintained at 5% O2. To determine whether this difference in metabolism was a reflection of the pluripotent state, hESCs were cultured at 5% O2 in the absence of FGF2 for 16 hours leading to a significant reduction in the expression of SOX2. In addition, these cells consumed less glucose and produced significantly less lactate compared to those cultured in the presence of FGF2. hESCs maintained at 5% O2 were found to consume significantly less O2 than those cultured in the absence of FGF2, or at 20% O2. GLUT1 expression correlated with glucose consumption and using siRNA and chromatin immunoprecipitation was found to be directly regulated by hypoxia inducible factor (HIF)-2α at 5% O2. In conclusion, highly pluripotent cells associated with hypoxic culture consume low levels of O2, high levels of glucose and produce large amounts of lactate, while at atmospheric conditions glucose consumption and lactate production are reduced and there is an increase in oxidative metabolism. These data suggest that environmental O2 regulates energy metabolism and is intrinsic to the self-renewal of hESCs.

  11. High or low oxygen saturation and severe retinopathy of prematurity: a meta-analysis.

    Science.gov (United States)

    Chen, Minghua L; Guo, Lei; Smith, Lois E H; Dammann, Christiane E L; Dammann, Olaf

    2010-06-01

    Low oxygen saturation appears to decrease the risk of severe retinopathy of prematurity (ROP) in preterm newborns when administered during the first few weeks after birth. High oxygen saturation seems to reduce the risk at later postmenstrual ages (PMAs). However, previous clinical studies are not conclusive individually. To perform a systematic review and meta-analysis to report the association between severe ROP incidence of premature infants with high or low target oxygen saturation measured by pulse oximetry. Studies were identified through PubMed and Embase literature searches through May 2009 by using the terms "retinopathy of prematurity and oxygen" or "retinopathy of prematurity and oxygen therapy." We selected 10 publications addressing the association between severe ROP and target oxygen saturation measured by pulse oximetry. Using a random-effects model we calculated the summary-effect estimate. We visually inspected funnel plots to examine possible publication bias. Low oxygen saturation (70%-96%) in the first several postnatal weeks was associated with a reduced risk of severe ROP (risk ratio [RR]: 0.48 [95% confidence interval (CI): 0.31-0.75]). High oxygen saturation (94%-99%) at > or = 32 weeks' PMA was associated with a decreased risk for progression to severe ROP (RR: 0.54 [95% CI: 0.35-0.82]). Among preterm infants with a gestational age of large randomized clinical trial with long-term developmental follow-up is warranted to confirm this meta-analytic result.

  12. The effect of oxygen tension in the sediment on the behaviour of waste radionuclides at the NEA Atlantic dumpsite

    International Nuclear Information System (INIS)

    Rutgers van der Loeff, M.M.; Waijers, D.A.

    1985-01-01

    Predictions of the transport and fate of waste radionuclides at the NEA Atlantic dumpsite require a knowledge of the behaviour of these nuclides within the sediment. Since redox conditions are known to influence the mobility of many elements in deep-sea sediments, we have investigated the speciation of some trace elements in relation to the dissolved oxygen concentration in sediments from the dumpsite. Dissolved oxygen in these sediments penetrates mostly between 50 and 100 cm, although at topographic highs and on hillsides oxygen penetrates more than 2 m into the sediment because of the special hydrodynamic and sedimentological conditions there. Remobilization at lowered redox potentials below the depth where oxygen reaches zero causes an upward diffusive transport of Mn and the manganese-associated trace metals Co and Ni. Whether this diagenetic mobilization influences other elements such as rare earth elements and actinides as well, remains to be investigated. Under normal sedimentological condition this mobilization can not be expected to return radioactivity to the water column through an oxidized sediment layer of 50 cm. However, burial of radioactivity to depths beyond the reach of deep burrowing organisms can be significantly delayed. Kd values (solid/dissolved partition coefficients) of redox sensitive elements vary over orders of magnitude and are inappropriate to model the behaviour of these elements in sediments with redox gradients

  13. Modeling combined tension-shear failure of ductile materials

    International Nuclear Information System (INIS)

    Partom, Y

    2014-01-01

    Failure of ductile materials is usually expressed in terms of effective plastic strain. Ductile materials can fail by two different failure modes, shear failure and tensile failure. Under dynamic loading shear failure has to do with shear localization and formation of adiabatic shear bands. In these bands plastic strain rate is very high, dissipative heating is extensive, and shear strength is lost. Shear localization starts at a certain value of effective plastic strain, when thermal softening overcomes strain hardening. Shear failure is therefore represented in terms of effective plastic strain. On the other hand, tensile failure comes about by void growth under tension. For voids in a tension field there is a threshold state of the remote field for which voids grow spontaneously (cavitation), and the material there fails. Cavitation depends on the remote field stress components and on the flow stress. In this way failure in tension is related to shear strength and to failure in shear. Here we first evaluate the cavitation threshold for different remote field situations, using 2D numerical simulations with a hydro code. We then use the results to compute examples of rate dependent tension-shear failure of a ductile material.

  14. Tension-controlled single-crystallization of copper foils for roll-to-roll synthesis of high-quality graphene films

    Science.gov (United States)

    Jo, Insu; Park, Subeom; Kim, Dongjin; San Moon, Jin; Park, Won Bae; Kim, Tae Hyeong; Hyoun Kang, Jin; Lee, Wonbae; Kim, Youngsoo; Lee, Dong Nyung; Cho, Sung-Pyo; Choi, Hyunchul; Kang, Inbyeong; Park, Jong Hyun; Lee, Jeong Soo; Hong, Byung Hee

    2018-04-01

    It has been known that the crystalline orientation of Cu substrates plays a crucial role in chemical vapor deposition (CVD) synthesis of high-quality graphene. In particular, Cu (1 1 1) surface showing the minimum lattice mismatch with graphene is expected to provide an ideal catalytic reactivity that can minimize the formation of defects, which also induces larger single-crystalline domain sizes of graphene. Usually, the Cu (1 1 1) substrates can be epitaxially grown on single-crystalline inorganic substrates or can be recrystallized by annealing for more than 12 h, which limits the cost and time-effective synthesis of graphene. Here, we demonstrate a new method to optimize the crystalline orientations of vertically suspended Cu foils by tension control during graphene growth, resulting in large-area recrystallization into Cu (1 1 1) surface as the applied tension activates the grain boundary energy of Cu and promotes its abnormal grain growth to single crystals. In addition, we found a clue that the formation of graphene cooperatively assists the recrystallization into Cu (1 1 1) by minimizing the surface energy of Cu. The domain sizes and charge carrier mobility of graphene grown on the single-crystalline Cu (1 1 1) are 5 times and ~50% increased, respectively, in comparison with those of graphene from Cu (1 0 0), indicating that the less lattice mismatch and the lower interaction energy between Cu (1 1 1) and graphene allows the growth of larger single-crystalline graphene with higher charge carrier mobility. Thus, we believe that our finding provides a crucial idea to design a roll-to-roll (R2R) graphene synthesis system where the tension control is inevitably involved, which would be of great importance for the continuous production of high-quality graphene in the future.

  15. Experimental and theoretical studies of oxygen gradients in rat pial microvessels

    OpenAIRE

    Sharan, Maithili; Vovenko, Eugene P; Vadapalli, Arjun; Popel, Aleksander S; Pittman, Roland N

    2008-01-01

    Using modified oxygen needle microelectrodes and intravital videomicroscopy, measurements were made of tissue oxygen tension (PO2) profiles near cortical arterioles and transmural PO2 gradients in the pial arterioles of the rat. Under control conditions, the transmural PO2 gradient averaged 1.17 ± 0.06 mm Hg/μm (mean ± s.e., n = 40). Local arteriolar dilation resulted in a marked decrease in the transmural PO2 gradient to 0.68 ± 0.04 mm Hg/μm (P < 0.001, n = 38). The major finding of this stu...

  16. Surface tension effects on vertical upward annular flows in a small diameter pipe

    Energy Technology Data Exchange (ETDEWEB)

    Sadatomi, Michio, E-mail: sadatomi@mech.kumamoto-u.ac.jp [Dept. of Advanced Mechanical Systems, Kumamoto Univ., 39-1, Kurokami 2-chome, Chuou-ku, Kumamoto 860-8555 (Japan); Kawahara, Akimaro [Dept. of Advanced Mechanical Systems, Kumamoto Univ., 39-1, Kurokami 2-chome, Chuou-ku, Kumamoto 860-8555 (Japan); Suzuki, Aruta [Plant Design & Engineering Dept., Environment, Energy & Plant Headquarters, Hitachi Zosen Corporation, 7-89, Nankokita 1-chome, Suminoe-ku, Osaka, 559-8559 (Japan)

    2016-12-15

    Highlights: • Surface tension effects were clarified on annular flow in a small diameter pipe. • The mean liquid film thickness became thinner with decreasing of surface tension. • The liquid droplet fraction and the interfacial shear stress became higher with it. • New prediction methods for the above parameters were developed and validated. - Abstract: Experiments were conducted to study the surface tension effects on vertical upward annular flows in a 5 mm I.D. pipe using water and low surface tension water with a little surfactant as the test liquid and air as the test gas. Firstly, the experimental results on the mean liquid film thickness, the liquid droplet fraction and the interfacial shear stress in annular flows together with some flow pictures are presented to clarify the surface tension effects. From these, the followings are clarified: In the low surface tension case, the liquid film surface becomes rough, the liquid film thickness thin, the liquid droplet fraction high, and the interfacial shear stress high. Secondary, correlations in literatures for the respective parameters are tested against the present data. The test results show that no correlation for the respective parameters could predict well the present data. Thus, correlations are revised by accounting for the surface tension effects. The results of the experiments, the correlations tests and their revisions mentioned above are presented in the present paper.

  17. Effects of in vitro low oxygen tension preconditioning of adipose stromal cells on their in vivo chondrogenic potential: application in cartilage tissue repair.

    Directory of Open Access Journals (Sweden)

    Sophie Portron

    Full Text Available PURPOSE: Multipotent stromal cell (MSC-based regenerative strategy has shown promise for the repair of cartilage, an avascular tissue in which cells experience hypoxia. Hypoxia is known to promote the early chondrogenic differentiation of MSC. The aim of our study was therefore to determine whether low oxygen tension could be used to enhance the regenerative potential of MSC for cartilage repair. METHODS: MSC from rabbit or human adipose stromal cells (ASC were preconditioned in vitro in control or chondrogenic (ITS and TGF-β medium and in 21 or 5% O2. Chondrogenic commitment was monitored by measuring COL2A1 and ACAN expression (real-time PCR. Preconditioned rabbit and human ASC were then incorporated into an Si-HPMC hydrogel and injected (i into rabbit articular cartilage defects for 18 weeks or (ii subcutaneously into nude mice for five weeks. The newly formed tissue was qualitatively and quantitatively evaluated by cartilage-specific immunohistological staining and scoring. The phenotype of ASC cultured in a monolayer or within Si-HPMC in control or chondrogenic medium and in 21 or 5% O2 was finally evaluated using real-time PCR. RESULTS/CONCLUSIONS: 5% O2 increased the in vitro expression of chondrogenic markers in ASC cultured in induction medium. Cells implanted within Si-HPMC hydrogel and preconditioned in chondrogenic medium formed a cartilaginous tissue, regardless of the level of oxygen. In addition, the 3D in vitro culture of ASC within Si-HPMC hydrogel was found to reinforce the pro-chondrogenic effects of the induction medium and 5% O2. These data together indicate that although 5% O2 enhances the in vitro chondrogenic differentiation of ASC, it does not enhance their in vivo chondrogenesis. These results also highlight the in vivo chondrogenic potential of ASC and their potential value in cartilage repair.

  18. "Train surfers": analysis of 23 cases of electrical burns caused by high tension railway overhead cables.

    Science.gov (United States)

    Sternick, I; Gomes, R D; Serra, M C; Radwanski, H N; Pitanguy, I

    2000-08-01

    The term "train surfers" describes a group of adolescents from the outskirts of the city of Rio de Janeiro, who are compelled by the overcrowded railway trains to travel on the roofs of the wagons. Collision with electrical high-tension wires is a relatively frequent occurrence, causing extensive and complex injuries. This study analyzes this clinical and surgical phenomenon which has caused over 100 fatalities in more than 200 registered accidents over the past 10 years.

  19. The Effective Lifetime of ACSR Full Tension Splice Connector Operated at Higher Temperature

    International Nuclear Information System (INIS)

    Wang, Jy-An John; Lara-Curzio, Edgar; King Jr, Thomas J.; Graziano, Joe; Chan, John; Goodwin, Tip

    2009-01-01

    This paper is to address the issues related to integrity of ACSR full tension splice connectors operated at high temperatures. A protocol of integrating analytical and experimental approaches to evaluate the integrity of a full tension single-stage splice connector (SSC) assembly during service at high operating temperature was developed. Based on the developed protocol the effective lifetime evaluation was demonstrated with ACSR Drake conductor SSC systems. The investigation indicates that thermal cycling temperature and frequency, conductor cable tension loading, and the compressive residual stress field within a SSC system have significant impact on the SSC integrity and the associated effective lifetime

  20. Autoionizing states in highly ionized oxygen, fluorine and silicon

    International Nuclear Information System (INIS)

    Forester, J.P.; Peterson, R.S.; Griffin, P.M.; Pegg, D.J.; Haselton, H.H.; Liao, K.H.; Sellin, I.A.; Mowat, J.R.; Thoe, R.S.

    1975-01-01

    Autoionizing states in high Z 3-electron ions associated with core excited configurations of the type 1s2snl and 1s2pnl are reported. The electron decay-in-flight spectra of lithium-like oxygen, fluorine, and silicon ions are presented. Initial beam energies of 6.75-MeV oxygen and fluorine ions and 22.5-MeV silicon ions were used. Stripping and excitation were done by passing the beams through a thin carbon foil. The experimental technique is described. 4 figs, 1 table, 7 refs

  1. Formation and evolution of tweed structures on high-purity aluminum polycrystalline foils under cyclic tension

    International Nuclear Information System (INIS)

    Kuznetsov, P. V.; Vlasov, I. V.; Sklyarova, E. A.; Smekalina, T. V.

    2015-01-01

    Peculiarities of formation and evolution of tweed structures on the surface of high-purity aluminum polycrystalline foils under cyclic tension were studied using an atom force microscope and a white light interferometer. Tweed structures of micron and submicron sizes were found on the foils at different number of cycles. In the range of 42,000 < N < 95,000 cycles destruction of tweed patterns is observed, which leads to their disappearance from the surface of the foils. Formation of tweed structures of various scales is discussed in terms of the Grinfeld instability

  2. Shape accuracy optimization for cable-rib tension deployable antenna structure with tensioned cables

    Science.gov (United States)

    Liu, Ruiwei; Guo, Hongwei; Liu, Rongqiang; Wang, Hongxiang; Tang, Dewei; Song, Xiaoke

    2017-11-01

    Shape accuracy is of substantial importance in deployable structures as the demand for large-scale deployable structures in various fields, especially in aerospace engineering, increases. The main purpose of this paper is to present a shape accuracy optimization method to find the optimal pretensions for the desired shape of cable-rib tension deployable antenna structure with tensioned cables. First, an analysis model of the deployable structure is established by using finite element method. In this model, geometrical nonlinearity is considered for the cable element and beam element. Flexible deformations of the deployable structure under the action of cable network and tensioned cables are subsequently analyzed separately. Moreover, the influence of pretension of tensioned cables on natural frequencies is studied. Based on the results, a genetic algorithm is used to find a set of reasonable pretension and thus minimize structural deformation under the first natural frequency constraint. Finally, numerical simulations are presented to analyze the deployable structure under two kinds of constraints. Results show that the shape accuracy and natural frequencies of deployable structure can be effectively improved by pretension optimization.

  3. Spontaneous tension haemopneumothorax.

    Science.gov (United States)

    Patterson, Benjamin Oliver; Itam, Sarah; Probst, Fey

    2008-10-31

    We present a patient with sudden onset progressive shortness of breath and no history of trauma, who rapidly became haemodynamically compromised with a pneumothorax and pleural effusion seen on chest radiograph. He was treated for spontaneous tension pneumothorax but this was soon revealed to be a tension haemopneumothorax. He underwent urgent thoracotomy after persistent bleeding to explore an apical vascular abnormality seen on CT scanning. To our knowledge this is the first such case reported.Aetiology and current approach to spontaneous haemothorax are discussed briefly.

  4. Is oxygen availability a limiting factor for in vitro folliculogenesis?

    Directory of Open Access Journals (Sweden)

    Riccardo Talevi

    Full Text Available Transplantation of ovarian tissue for the preservation of fertility in oncological patients is becoming an accepted clinical practice. However, the risk of re-introducing tumour cells at transplantation has stirred an increased interest for complete in vitro folliculogenesis. This has not yet been achieved in humans possibly for the lack of knowledge on the environmental milieu that orchestrates folliculogenesis in vivo. The main aim of this study was to investigate the effect of oxygen availability on follicle health and growth during in vitro culture of ovarian tissue strips. To this end, a model was developed to predict the dissolved oxygen concentration in tissue under varying culture conditions. Ovarian cortical strips of bovine, adopted as an animal model, and human tissue were cultured in conventional (CD and gas permeable (PD dishes under different media column heights and gaseous oxygen tensions for 3, 6 and 9 days. Follicle quality, activation of primordial follicles to the primary stage, and progression to the secondary stage were analysed through histology. Follicle viability was assessed through a live-dead assay at the confocal scanning laser microscope. Findings showed a higher follicle quality and viability after culture of bovine ovarian strips in PD in adequate medium height and oxygen tensions. The best culture conditions found in the bovine were adopted for human ovarian strip culture and promoted a higher follicle quality, viability and progression. Overall, data demonstrated that modulation of oxygen availability in tissue plays a key role in maintaining follicles' health and their ability to survive and progress to the secondary stage during ovarian tissue in vitro culture. Such culture conditions could increase the yield of healthy secondary follicles for subsequent dissection and individual culture to obtain competent oocytes.

  5. Correlation of cutaneous tension distribution and tissue oxygenation with acute external tissue expansion

    Directory of Open Access Journals (Sweden)

    Marquardt C

    2009-11-01

    Full Text Available Abstract Today, the biomechanical fundamentals of skin expansion are based on viscoelastic models of the skin. Although many studies have been conducted in vitro, analyses performed in vivo are rare. Here, we present in vivo measurements of the expansion at the skin surface as well as measurement of the corresponding intracutaneous oxygen partial pressure. In our study the average skin stretching was 24%, with a standard deviation of 11%, excluding age or gender dependency. The measurement of intracutaneous oxygen partial pressure produced strong inter-individual fluctuations, including initial values at the beginning of the measurement, as well as varying individual patient reactions to expansion of the skin. Taken together, we propose that even large defect wounds can be closed successfully using the mass displacement caused by expansion especially in areas where soft, voluminous tissue layers are present.

  6. Ketogenic diet for high partial pressure oxygen diving.

    Science.gov (United States)

    Valadao, Jason M; Vigilante, John A; DiGeorge, Nicholas W; O'Connor, Sunila E; Bear, Alexandria; Kenyon, Jeffrey; Annis, Heather; Dituri, Joseph; Dituri, Amy E; Whelan, Harry T

    2014-01-01

    A ketogenic diet (KD) may decrease central nervous system oxygen toxicity symptoms in divers, and in view of this implication a feasibility/ toxicity pilot study was performed to demonstrate tolerance of KD while performing normal diving profiles. The exact mechanism of neuroprotection from the KD remains unknown; however, evidence to support the efficacy of the KD in reducing seizures is present in epilepsy and oxygen toxicity studies, and may provide valuable insight in diving activities. Three divers (two males and one female ages 32-45 with a history of deep diving and high pO2 exposure) on the KD made dives to varying depths in Hawaii using fully closed-circuit MK-15 and Inspiration rebreathers. These rebreathers have an electronically controlled set point, allowing the divers to monitor and control the oxygen level in the breathing loop, which can be varied manually by the divers. Oxygen level was varied during descent, bottom depth and ascent (decompression). Divers fasted for 12-18 hours before diet initiation. The ketosis level was verified by urinating on a Ketostix (reagent strips for urinalysis). Ketosis was achieved and was easily monitored with Ketostix in the simulated operational environment. The KD did not interfere with the diving mission; no seizure activity or signs or symptoms of CNS toxicity were observed, and there were no adverse effects noted by the divers while on the KD.

  7. The duality of tensions at the workplace for female leaders

    OpenAIRE

    Haidinger, Julia

    2017-01-01

    The qualitative research undertaken was set out to understand the challenges experienced by female leaders at the workplace. Therefore, semi-structured interviews with 12 female leaders in top management positions from different industries were conducted. As a consequence, a duality between tensions concerning 1) character traits, 2) beauty and 3) motherhood was confirmed through the experiences shared by the participants. Women identified these tensions as highly challenging and difficult to...

  8. Spontaneous tension haemopneumothorax

    Directory of Open Access Journals (Sweden)

    Itam Sarah

    2008-10-01

    Full Text Available Abstract We present a patient with sudden onset progressive shortness of breath and no history of trauma, who rapidly became haemodynamically compromised with a pneumothorax and pleural effusion seen on chest radiograph. He was treated for spontaneous tension pneumothorax but this was soon revealed to be a tension haemopneumothorax. He underwent urgent thoracotomy after persistent bleeding to explore an apical vascular abnormality seen on CT scanning. To our knowledge this is the first such case reported. Aetiology and current approach to spontaneous haemothorax are discussed briefly.

  9. Additive influence of extracellular pH, oxygen tension, and pressure on invasiveness and survival of human osteosarcoma cells

    Directory of Open Access Journals (Sweden)

    Takao eMatsubara

    2013-07-01

    Full Text Available BACKGROUND/PURPOSE:The effects of chemical and physical interactions in the microenvironment of solid tumors have not been fully elucidated. We hypothesized that acidosis, hypoxia, and elevated interstitial fluid pressure (eIFP have additive effects on tumor cell biology and lead to more aggressive behavior during tumor progression. We investigated this phenomenon using 3 human osteosarcoma cell lines and a novel in vitro cell culture apparatus. MATERIALS AND METHODS:U2OS, SaOS, and MG63 cell lines were cultured in media adjusted to various pH levels, oxygen tension (hypoxia 2% O2, normoxia 20% O2, and hydrostatic gauge pressure (0 or 50 mm Hg. Growth rate, apoptosis, cell cycle parameters, and expression of mRNA for proteins associated with invasiveness and tumor microenvironment (CA IX, VEGF-A, HIF-1A, MMP-9, and TIMP-2 were analyzed. Levels of CA IX, HIF-1α, and MMP-9 were measured using immunofluorescence. The effect of pH on invasiveness was evaluated in a Matrigel chamber assay.RESULTS: Within the acidic–hypoxic–pressurized conditions that simulate the microenvironment at a tumor’s center, invasive genes were upregulated, but the cell cycle was downregulated. The combined influence of acidosis, hypoxia, and IFP promoted invasiveness and angiogenesis to a greater extent than did pH, pO2, or eIFP individually. Significant cell death after brief exposure to acidic conditions occurred in each cell line during acclimation to acidic media, while prolonged exposure to acidic media resulted in reduced cell death. Furthermore, 48-hour exposure to acidic conditions promoted tumor invasiveness in the Matrigel assay. CONCLUSION: Our findings demonstrate that tumor microenvironmental parameters—particularly pH, pO2, and eIFP—additively influence tumor proliferation, invasion, metabolism, and viability to enhance cell survival.

  10. The Role of Oxygen Sensors, Hydroxylases, and HIF in Cardiac Function and Disease

    Directory of Open Access Journals (Sweden)

    W. H. Davin Townley-Tilson

    2015-01-01

    Full Text Available Ischemic heart disease is the leading cause of death worldwide. Oxygen-sensing proteins are critical components of the physiological response to hypoxia and reperfusion injury, but the role of oxygen and oxygen-mediated effects is complex in that they can be cardioprotective or deleterious to the cardiac tissue. Over 200 oxygen-sensing proteins mediate the effects of oxygen tension and use oxygen as a substrate for posttranslational modification of other proteins. Hydroxylases are an essential component of these oxygen-sensing proteins. While a major role of hydroxylases is regulating the transcription factor HIF, we investigate the increasing scope of hydroxylase substrates. This review discusses the importance of oxygen-mediated effects in the heart as well as how the field of oxygen-sensing proteins is expanding, providing a more complete picture into how these enzymes play a multifaceted role in cardiac function and disease. We also review how oxygen-sensing proteins and hydroxylase function could prove to be invaluable in drug design and therapeutic targets for heart disease.

  11. Toward a general psychological model of tension and suspense.

    Science.gov (United States)

    Lehne, Moritz; Koelsch, Stefan

    2015-01-01

    Tension and suspense are powerful emotional experiences that occur in a wide variety of contexts (e.g., in music, film, literature, and everyday life). The omnipresence of tension and suspense suggests that they build on very basic cognitive and affective mechanisms. However, the psychological underpinnings of tension experiences remain largely unexplained, and tension and suspense are rarely discussed from a general, domain-independent perspective. In this paper, we argue that tension experiences in different contexts (e.g., musical tension or suspense in a movie) build on the same underlying psychological processes. We discuss key components of tension experiences and propose a domain-independent model of tension and suspense. According to this model, tension experiences originate from states of conflict, instability, dissonance, or uncertainty that trigger predictive processes directed at future events of emotional significance. We also discuss possible neural mechanisms underlying tension and suspense. The model provides a theoretical framework that can inform future empirical research on tension phenomena.

  12. [Cognitive behavioral therapy for tension-type headache: a case report].

    Science.gov (United States)

    Salman, İsmail Barış; Sertel Berk, Hanife Özlem

    2017-10-01

    Tension-type headache has a very high socioeconomic impact, and its lifetime prevalence is reported to be between 30% and 78% in different studies. It is widely acknowledged that noninvasive management with a multidisciplinary approach should be considered for the treatment of tension-type headache. Cognitive behavioral therapy and relaxation exercises are efficient techniques. This article illustrates the application of a cognitive behavioral therapy protocol enhanced with progressive muscle stretching and relaxation exercises in the treatment of chronic tension-type headache via a case report. Our patient had an ongoing headache for 6 years when he was referred to us by the department of psychiatry. After 10 cognitive behavioral therapy sessions, the patient had learned to notice muscle tension and relax the muscles as well as to recognize and express his emotions in a better way. He became aware of automatic thoughts and learned to find alternative thoughts. Headache severity decreased, and he was able to increase participation in daily life activities.

  13. High-temperature reaction of ''anisotropic'' pyrolitic graphite with oxygen

    International Nuclear Information System (INIS)

    Lavrenko, V.A.; Pomytkin, A.P.; Neshpor, V.S.; Vinokur, F.L.

    1980-01-01

    Investigated is the kinetics of initial interaction stages of highly dense crystalloorientated pyrographite with oxygen. Oxidation was carried out in pure oxygen within 0.1-740 mm Hg pressure range and 500-1100 deg C temperature range. It is stated, that at the temperatures below 700 deg C pyrographite oxidation is subjected to a linear law. Above 700-800 deg C the linear law is preserved only at the initial oxidation stage, then the process is described by a parabolic law. Extension of the linear site is decreased in time with the reduction of oxygen pressure. The reaction has apparent fractional order. Activation energy of pyrogrpahite oxidation by the linear low constitutes approximately 58 kcal/mol within 600-800 deg C range and 14 kcal/mol within 800-1100 deg C range. The apparent activation energy constitutes approximately 13 kcal/mol in the region of correspondence to the parabolic law

  14. The impact of including spatially longitudinal heterogeneities of vessel oxygen content and vascular fraction in 3D tumor oxygenation models on predicted radiation sensitivity.

    Science.gov (United States)

    Lagerlöf, Jakob H; Kindblom, Jon; Bernhardt, Peter

    2014-04-01

    Oxygen distribution models have been used to analyze the influences of oxygen tensions on tissue response after radiotherapy. These distributions are often generated assuming constant oxygen tension in the blood vessels. However, as red blood cells progress through the vessels, oxygen is continuously released into the plasma and the surrounding tissue, resulting in longitudinally varying oxygen levels in the blood vessels. In the present study, the authors investigated whether a tumor oxygenation model that incorporated longitudinally varying oxygen levels would provide different predictions of necrotic fractions and radiosensitivity compared to commonly used models with a constant oxygen pressure. Our models simulated oxygen diffusion based on a Green's function approach and oxygen consumption according to the Michaelis-Menten equation. The authors constructed tumor models with different vascular fractions (VFs), from which they generated depth oxygenation curves and a look-up table of oxygen pressure gradients. The authors evaluated models of spherical tumors of various sizes, from 1 to 10(4) mg. The authors compared the results from a model with constant vessel oxygen (CVO) pressure to those from models with longitudinal variations in oxygen saturation and either a constant VF (CVF) or variable VF (VVF) within the tumor tissue. The authors monitored the necrotic fractions, defined as tumor regions with an oxygen pressure below 1 mmHg. Tumor radiation sensitivity was expressed as D99, the homogeneous radiation dose required for a tumor control probability of 0.99. In the CVO saturation model, no necrosis was observed, and decreasing the VF could only decrease the D99 by up to 10%. Furthermore, the D99 vs VF dependence was similar for different tumor masses. Compared to the CVO model, the extended CVF and VVF models provided clearly different results, including pronounced effects of VF and tumor size on the necrotic fraction and D99, necrotic fractions ranging

  15. Analysis of gas turbine engines using water and oxygen injection to achieve high Mach numbers and high thrust

    Science.gov (United States)

    Henneberry, Hugh M.; Snyder, Christopher A.

    1993-01-01

    An analysis of gas turbine engines using water and oxygen injection to enhance performance by increasing Mach number capability and by increasing thrust is described. The liquids are injected, either separately or together, into the subsonic diffuser ahead of the engine compressor. A turbojet engine and a mixed-flow turbofan engine (MFTF) are examined, and in pursuit of maximum thrust, both engines are fitted with afterburners. The results indicate that water injection alone can extend the performance envelope of both engine types by one and one-half Mach numbers at which point water-air ratios reach 17 or 18 percent and liquid specific impulse is reduced to some 390 to 470 seconds, a level about equal to the impulse of a high energy rocket engine. The envelope can be further extended, but only with increasing sacrifices in liquid specific impulse. Oxygen-airflow ratios as high as 15 percent were investigated for increasing thrust. Using 15 percent oxygen in combination with water injection at high supersonic Mach numbers resulted in thrust augmentation as high as 76 percent without any significant decrease in liquid specific impulse. The stoichiometric afterburner exit temperature increased with increasing oxygen flow, reaching 4822 deg R in the turbojet engine at a Mach number of 3.5. At the transonic Mach number of 0.95 where no water injection is needed, an oxygen-air ratio of 15 percent increased thrust by some 55 percent in both engines, along with a decrease in liquid specific impulse of 62 percent. Afterburner temperature was approximately 4700 deg R at this high thrust condition. Water and/or oxygen injection are simple and straightforward strategies to improve engine performance and they will add little to engine weight. However, if large Mach number and thrust increases are required, liquid flows become significant, so that operation at these conditions will necessarily be of short duration.

  16. Pressure balanced type membrane covered polarographic oxygen detectors for use in high temperature-high pressure water, (1)

    International Nuclear Information System (INIS)

    Nakayama, Norio; Uchida, Shunsuke

    1984-01-01

    A pressure balanced type membrane covered polarographic oxygen detector was developed to determine directly oxygen concentrations in high temperature, high pressure water without cooling and pressure reducing procedures. The detector is characterized by the following features: (1) The detector body and the membrane for oxygen penetration are made of heat resistant resin. (2) The whole detector body is contained in a pressure chamber where interior and exterior pressures of the detector are balanced. (3) Thermal expansion of the electrolyte is absorbed by deformation of a diaphragm attached to the detector bottom. (4) The effect of dissolved Ag + on the signal current is eliminated by applying a guard electrode. As a result of performance tests at elevated temperature, it was demonstrated that a linear relationship between oxygen concentration and signal current was obtained up to 285 0 C, which was stabilized by the guard electrode. The minimum O 2 concentration detectable was 0.03ppm (9.4 x 10 -7 mol/kg). (author)

  17. Tension type headaches: a review

    African Journals Online (AJOL)

    Location of the pain:There is often a typical location for tension- type headaches, as ... Cranial nerve abnormalities, including papilloedema. • Signs of ... peripheral and central mechanisms underlie tension-type ... Physiotherapy has been shown to be an effective management option for .... Acupuncture in primary headache.

  18. Post-tensioning system surveillance program

    International Nuclear Information System (INIS)

    Drew, G.E.

    1979-01-01

    Nuclear power plant containment structure post-tensioning system tendon surveillance program is described in detail. Data collected over three yearly post-tensioning system Surveillance Programs is presented and evaluated to correlate anticipated stress losses with actual losses. In addition corrosion protected system performance is analyzed

  19. Constraining brane tension using rotation curves of galaxies

    Science.gov (United States)

    García-Aspeitia, Miguel A.; Rodríguez-Meza, Mario A.

    2018-04-01

    We present in this work a study of brane theory phenomenology focusing on the brane tension parameter, which is the main observable of the theory. We show the modifications steaming from the presence of branes in the rotation curves of spiral galaxies for three well known dark matter density profiles: Pseudo isothermal, Navarro-Frenk-White and Burkert dark matter density profiles. We estimate the brane tension parameter using a sample of high resolution observed rotation curves of low surface brightness spiral galaxies and a synthetic rotation curve for the three density profiles. Also, the fittings using the brane theory model of the rotation curves are compared with standard Newtonian models. We found that Navarro-Frenk-White model prefers lower values of the brane tension parameter, on the average λ ∼ 0.73 × 10‑3eV4, therefore showing clear brane effects. Burkert case does prefer higher values of the tension parameter, on the average λ ∼ 0.93 eV4 ‑ 46 eV4, i.e., negligible brane effects. Whereas pseudo isothermal is an intermediate case. Due to the low densities found in the galactic medium it is almost impossible to find evidence of the presence of extra dimensions. In this context, we found that our results show weaker bounds to the brane tension values in comparison with other bounds found previously, as the lower value found for dwarf stars composed of a polytropic equation of state, λ ≈ 104 MeV4.

  20. Oxygenation of the traditional and thin-walled MT-YBCO in flowing oxygen and under high evaluated oxygen pressure

    International Nuclear Information System (INIS)

    Prikhna, Tatiana; Chaud, Xavier; Gawalek, Wolfgang; Rabier, Jaques; Savchuk, Yaroslav; Joulain, Anne; Vlasenko, Andrey; Moshchil, Viktor; Sergienko, Nina; Dub, Sergey; Melnikov, Vladimir; Litzkendorf, Doris; Habisreuther, Tobias; Sverdun, Vladimir

    2007-01-01

    The high pressure-high temperature oxygenation of thin-walled MT-YBCO (with artificially produced holes) allows decreasing the amount of macrocracks and increasing j c of the material. The MT-YBCO produced from Y123 and Y211 in the fields higher than 2 T showed higher j c in the ab-planes and lower j c in the c-direction than the MT-YBCO manufactured from Y123 and Y 2 O 3 and can be explained by the difference in twin and microcrack density that in turn can be affected by the difference in Y211 phase distribution

  1. End-Tidal CO2 Tension Is Predictive of Effective Nocturnal Oxygen Therapy in Patients with Chronic Heart Failure and Central Sleep Apnea.

    Science.gov (United States)

    Sugimura, Koichiro; Shinozaki, Tsuyoshi; Fukui, Shigefumi; Ogawa, Hiromasa; Shimokawa, Hiroaki

    2016-05-01

    Central sleep apnea (CSA) is characterized by recurring cycles of crescendo-decrescendo ventilation during sleep, and enhances sympathetic nerve activity. Thus CSA has a prognostic impact in patients with chronic heart failure (CHF). Although nocturnal oxygen (O2) therapy decreases frequency of CSA and improves functional exercise capacity, it is also known that some non-responders to the therapy exist. We thus aimed to identify predictors of responders to nocturnal O2 therapy in CHF patients with CSA. In 12 CHF patients with CSA hospitalized at our department, sleep study was performed at 2 consecutive nights. Patients nasally inhaled O2 at either the first or second night in a randomized manner. To predict the percentage reduction in apnea-hypopnea index (%ΔAHI) in response to the nocturnal O2 therapy, we performed multiple regression analysis with a stepwise method with variables including age, brain-natriuretic peptide, circulation time, baseline AHI, hypercapnic ventilatory response and end-tidal carbon dioxide tension (PETCO2). Nocturnal O2 therapy significantly decreased AHI (from 32 ± 13 /h to 12 ± 10 /h, P 50% reduction of AHI), with 88.9% of sensitivity and 66.7% of specificity. In conclusion, PETCO2 is useful to predict the efficacy of O2 therapy in CHF patients with CSA, providing important information to the current nocturnal O2 therapy.

  2. Fabrication of high surface area graphene electrodes with high performance towards enzymatic oxygen reduction

    International Nuclear Information System (INIS)

    Di Bari, Chiara; Goñi-Urtiaga, Asier; Pita, Marcos; Shleev, Sergey; Toscano, Miguel D.; Sainz, Raquel; De Lacey, Antonio L.

    2016-01-01

    High surface area graphene electrodes were prepared by simultaneous electrodeposition and electroreduction of graphene oxide. The electrodeposition process was optimized in terms of pH and conductivity of the solution and the obtained graphene electrodes were characterized by X-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, scanning electron microscopy and electrochemical methods (cyclic voltammetry and impedance spectroscopy). Electrodeposited electrodes were further functionalized to carry out covalent immobilization of two oxygen-reducing multicopper oxidases: laccase and bilirubin oxidase. The enzymatic electrodes were tested as direct electron transfer based biocathodes and catalytic currents as high as 1 mA/cm 2 were obtained. Finally, the mechanism of the enzymatic oxygen reduction reaction was studied for both enzymes calculating the Tafel slopes and transfer coefficients.

  3. Escape of high-energy oxygen ions through magnetopause reconnection under northward IMF

    Directory of Open Access Journals (Sweden)

    S. Kasahara

    2008-12-01

    Full Text Available During a storm recovery phase on 15 May 2005, the Geotail spacecraft repeatedly observed high-energy (>180 keV oxygen ions in the dayside magnetosheath near the equatorial plane. We focused on the time period from 11:20 UT to 13:00 UT, when Geotail observed the oxygen ions and the interplanetary magnetic field (IMF was constantly northward. The magnetic reconnection occurrence northward and duskward of Geotail is indicated by the Walén analysis and convective flows in the magnetopause boundary layer. Anisotropic pitch angle distributions of ions suggest that high-energy oxygen ions escaped from the northward of Geotail along the reconnected magnetic field lines. From the low-energy particle precipitation in the polar cap observed by DMSP, which is consistent with magnetic reconnection occurring between the magnetosheath field lines and the magnetospheric closed field lines, we conclude that these oxygen ions are of ring current origin. Our results thus suggest a new escape route of oxygen ions during northward IMF. In the present event, this escape mechanism is more dominant than the leakage via the finite Larmor radius effect across the dayside equatorial magnetopause.

  4. A theoretical evaluation of the oxygen concentration in a corrosion-fatigue crack

    International Nuclear Information System (INIS)

    Turnbull, A.

    1981-01-01

    The oxygen concentration in a corrosion-fatigue crack has been evaluated theoretically by assuming that oxygen was consumed by cathodic reduction on the walls of the crack and mass transport occurred by diffusion and advection (forced convection), with the latter resulting from the sinusoidal variation of the displacement of the crack walls. By using parameters relevant to a compact tension specimen, the time-dependent distribution of the oxygen concentration in the crack was calculated as a function of ΔK (the range of the stress intensity factor), R-value (minimum load/maximum load), frequency, crack length, and electrode potential. The influence of advection was to significantly enhance the mass transport of oxygen in the crack compared with ''diffusion-only'' even at low frequencies and low ΔK. Regions in the crack were identified in which advection dominance or diffusion dominance of the mass transport of oxygen occurred

  5. [Tension gastrothorax as a cause of death by obstructive shock - case report].

    Science.gov (United States)

    García-Regalado, Juan F; Navarro-Rojas, Mariana M

    2014-07-01

    Tension gastrothorax is caused by the herniation of the stomach into the thorax due to a congenital defect of the diaphragm; the Bochdaleck diaphragmatic hernia (HDB) is the most frequent type. Tension gastrothorax should be considered as a differential diagnosis in patients with obstructive shock and tension pneumothorax. A previously healthy 10 month-old male infant, who presented increased respiratory distress, increased volume of the left hemithorax, absence of breath sounds, ipsilateral hyper-resonance, 76% saturation, cold skin and capillary filling > 5 seconds, followed by a cardio-respiratory arrest. Due to clinical suspicion of pneumothorax, needle decompression was performed reversing cardiac arrest, but with persistent hemodynamic and respiratory instability; chest radiograph suggested diaphragmatic hernia. He underwent surgery confirming the presence of a diaphragmatic hernia of 5 cm. The evolution of this case shows the difficulty differentiating a tension gastrothorax from tension pneumothorax in patients admitted to the emergency room who are in serious condition; therefore, a high index of suspicion is needed for its identification.

  6. Delayed Tension Pneumothorax - Identification and Treatment in Traumatic Bronchial Injury: An Interesting Presentation.

    Science.gov (United States)

    Gupta, Amit; Rattan, Amulya; Kumar, Sunil; Rathi, Vinita

    2017-09-01

    A 13-year-old girl, who did not receive any treatment for few hours following Road Traffic Injury (RTI), reported to the Casualty Department and found to have patent airway with clinically normal C spine, air-hunger (RR 42/minute), trachea deviated to left, distended neck veins and absent breath sounds on the right side. The chest X-ray she carried, done immediately after the injury, showed right sided tension pneumothorax. She was put on oxygen at 11 L/minute and an Intercostal chest tube drainage (ICD) was inserted on right side. Her oxygen saturation (40%) failed to improve. ICD bag showed continuous bubbling and air entry remained absent on the right side. An urgent right thoracotomy was done which revealed right main bronchus tear; the tear was repaired using interrupted Prolene ® sutures. Patient recovered well and was discharged 10 days later in a stable condition.

  7. Comparison Between Cerebral Tissue Oxygen Tension and Energy Metabolism in Experimental Subdural Hematoma

    DEFF Research Database (Denmark)

    Nielsen, Troels Halfeld; Engell, Susanne I; Johnsen, Rikke Aagaard

    2011-01-01

    BACKGROUND: An experimental swine model (n = 7) simulating an acute subdural hematoma (ASDH) was employed (1) to explore the relation between the brain tissue oxygenation (PbtO(2)) and the regional cerebral energy metabolism as obtained by microdialysis, and (2) to define the lowest level of PbtO(2...

  8. Nasal high flow therapy: a novel treatment rather than a more expensive oxygen device

    Directory of Open Access Journals (Sweden)

    Eleni Ischaki

    2017-09-01

    Full Text Available Nasal high flow is a promising novel oxygen delivery device, whose mechanisms of action offer some beneficial effects over conventional oxygen systems. The administration of a high flow of heated and humidified gas mixture promotes higher and more stable inspiratory oxygen fraction values, decreases anatomical dead space and generates a positive airway pressure that can reduce the work of breathing and enhance patient comfort and tolerance. Nasal high flow has been used as a prophylactic tool or as a treatment device mostly in patients with acute hypoxaemic respiratory failure, with the majority of studies showing positive results. Recently, its clinical indications have been expanded to post-extubated patients in intensive care or following surgery, for pre- and peri-oxygenation during intubation, during bronchoscopy, in immunocompromised patients and in patients with “do not intubate” status. In the present review, we differentiate studies that suggest an advantage (benefit from other studies that do not suggest an advantage (no benefit compared to conventional oxygen devices or noninvasive ventilation, and propose an algorithm in cases of nasal high flow application in patients with acute hypoxaemic respiratory failure of almost any cause.

  9. Comparison of the effectiveness of high flow nasal oxygen cannula vs. standard non-rebreather oxygen face mask in post-extubation intensive care unit patients.

    Science.gov (United States)

    Brotfain, Evgeni; Zlotnik, Alexander; Schwartz, Andrei; Frenkel, Amit; Koyfman, Leonid; Gruenbaum, Shaun E; Klein, Moti

    2014-11-01

    Optimal oxygen supply is the cornerstone of the management of critically ill patients after extubation, especially in patients at high risk for extubation failure. In recent years, high flow oxygen system devices have offered an appropriate alternative to standard oxygen therapy devices such as conventional face masks and nasal prongs. To assess the clinical effects of high flow nasal cannula (HFNC) compared with standard oxygen face masks in Intensive Care Unit (ICU) patients after extubation. We retrospectively analyzed 67 consecutive ventilated critical care patients in the ICU over a period of 1 year. The patients were allocated to two treatment groups: HFNC (34 patients, group 1) and non-rebreathing oxygen face mask (NRB) (33 patients, group 2). Vital respiratory and hemodynamic parameters were assessed prior to extubation and 6 hours after extubation. The primary clinical outcomes measured were improvement in oxygenation, ventilation-free days, re-intubation, ICU length of stay, and mortality. The two groups demonstrated similar hemodynamic patterns before and after extubation. The respiratory rate was slightly elevated in both groups after extubation with no differences observed between groups. There were no statistically significant clinical differences in PaCO2. However, the use of HFNC resulted in improved PaO2/FiO2 post-extubation (P < 0.05). There were more ventilator-free days in the HFNC group (P< 0.05) and fewer patients required reintubation (1 vs. 6). There were no differences in ICU length of stay or mortality. This study demonstrated better oxygenation for patients treated with HFNC compared with NRB after extubation. HFNC may be more effective than standard oxygen supply devices for oxygenation in the post-extubation period.

  10. High temperature microcalorimetry. Study of metal-oxygen systems

    International Nuclear Information System (INIS)

    Tetot, R.; Picard, C.; Boureau, G.; Gerdanian, P.

    1981-01-01

    Determination of partial molar enthalpy in metal-oxygen systems at 1050 0 C. Three representative systems are studied: the solution of oxygen in titanium, the titanium-oxygen system and the uranium-oxygen system from UOsub(2.00) to UOsub(2.60) [fr

  11. Detection of cerebral arterial gas embolism using regional cerebral oxygen saturation, quantitative electroencephalography, and brain oxygen tension in the swine

    NARCIS (Netherlands)

    Weenink, R. P.; Hollmann, M. W.; Stevens, M. F.; Kager, J.; van Gulik, T. M.; van Hulst, R. A.

    2014-01-01

    Cerebral air emboli occur as a complication of invasive medical procedures. The sensitivity of cerebral monitoring methods for the detection of air emboli is not known. This study investigates the utility of electroencephalography and non-invasively measured cerebral oxygen saturation in the

  12. Perceiving the affordance of string tension for power strokes in badminton: expertise allows effective use of all string tensions.

    Science.gov (United States)

    Zhu, Qin

    2013-01-01

    Affordances mean opportunities for action. These affordances are important for sports performance and relevant to the abilities developed by skilled athletes. In racquet sports such as badminton, different players prefer widely different string tension because it is believed to provide opportunities for effective strokes. The current study examined whether badminton players can perceive the affordance of string tension for power strokes and whether the perception of affordance itself changed as a function of skill level. The results showed that string tension constrained the striking performance of both novice and recreational players, but not of expert players. When perceptual capability was assessed, perceptual mode did not affect perception of the optimal string tension. Skilled players successfully perceived the affordance of string tension, but only experts were concerned about saving energy. Our findings demonstrated that perception of the affordance of string tension in badminton was determined by action abilities. Furthermore, experts could adjust the action to maintain a superior level of performance based on the perception of affordance.

  13. The partial pressure of oxygen affects biomarkers of oxidative stress in cultured rainbow trout (Oncorhynchus mykiss) hepatocytes.

    Science.gov (United States)

    Finne, E F; Olsvik, P A; Berntssen, M H G; Hylland, K; Tollefsen, K E

    2008-09-01

    Oxidative stress, the imbalance between production of reactive oxygen species and the cellular detoxification of these reactive compounds, is believed to be involved in the pathology of various diseases. Several biomarkers for oxidative stress have been proposed to serve as tools in toxicological and ecotoxicological research. Not only may exposure to various pro-oxidants create conditions of cellular oxidative stress, but hyperoxic conditions may also increase the production of reactive oxygen species. The objective of the current study was to determine the extent to which differences in oxygen partial pressure would affect biomarkers of oxidative stress in a primary culture of hepatocytes from rainbow trout (Oncorhynchus mykiss). Membrane integrity, metabolic activity, levels of total and oxidized glutathione (tGSH/GSSG) was determined, as well as mRNA expression levels of the antioxidant enzymes superoxide dismutase (SOD), catalase (CAT), glutathione peroxidase (GSH-Px), glutathione reductase (GSSG-R), gamma-glutamyl-cystein synthetase (GCS) and thioredoxin (TRX). The results show that different biomarkers of oxidative stress are affected when the cell culture is exposed to atmospheric oxygen, and that changes such as increased GSSG content and induction of GSSG-R and GSH-Px can be reduced by culturing the cells under lower oxygen tension. Oxygen tension may thus influence results of in vitro based cell research and is particularly important when assessing parameters in the antioxidant defence system. Further research is needed to establish the magnitude of this effect in different cellular systems.

  14. Development of high power chemical oxygen lodine laser

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Cheol Jung; Choi, Y. D.; Chung, C. M.; Kim, M. S.; Baik, S. H.; Kwon, S. O.; Park, S. K.; Kim, T. S

    2001-10-01

    This project is directed to construct 10kW Chemical Oxygen Iodine Laser (COIL) for decommissioning of old nuclear facilities, and to get the key technology that can be used for the development of high energy laser weapon. COIL is possible up to MW class in proportion to the amount of chemical reaction. For this reason, high energy laser weapon including Airborne Laser (ABL) and Airborne Tactical Laser (ATL) has been developed as a military use in USA. Recently, many research group have been doing a development study of COIL for nuclear and industrial use in material processing such as cutting and decommissioning by combining laser beam delivery through optical fiber. The Chemical Oxygen Iodine Laser of 6 kW output power has been developed in this project. The main technologies of chemical reaction and supersonic fluid control were developed. This technology can be applied for construction of 10 kW laser system. This laser can be used for old nuclear facilities and heavy industry by combining laser beam delivery through optical fiber. The development of High Energy Laser (HEL) weapon is necessary as a military use, and we conclude that Airborne Tactical Laser should be developed in our country.

  15. Innovative encapsulated oxygen-releasing beads for bioremediation of BTEX at high concentration in groundwater.

    Science.gov (United States)

    Lin, Chi-Wen; Wu, Chih-Hung; Guo, Pei-Yu; Chang, Shih-Hsien

    2017-12-15

    Both a low concentration of dissolved oxygen and the toxicity of a high concentration of BTEX inhibit the bioremediation of BTEX in groundwater. A novel method of preparing encapsulated oxygen-releasing beads (encap-ORBs) for the biodegradation of BTEX in groundwater was developed. Experimental results show that the integrality and oxygen-releasing capacity of encap-ORBs exceeded those of ORBs. The use of polyvinyl alcohol (PVA) with high M.W. to prepare encap-ORBs improved their integrality. The encap-ORBs effectively released oxygen for 128 days. High concentration of BTEX (480 mg L -1 ) inhibited the biodegradation by the free cells. Immobilization of degraders in the encap-ORB alleviated the inhibition. Scanning electron microscope analysis reveals that the BTEX degraders grew on the surface of encap-ORB after bioremediation. The above results indicate that the encap-ORBs were effective in the bioremediation of BTEX at high concentration in groundwater. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. International Space Station (ISS) Oxygen High Pressure Storage Management

    Science.gov (United States)

    Lewis, John R.; Dake, Jason; Cover, John; Leonard, Dan; Bohannon, Carl

    2004-01-01

    High pressure oxygen onboard the ISS provides support for Extra Vehicular Activities (EVA) and contingency metabolic support for the crew. This high pressure 02 is brought to the ISS by the Space Shuttle and is transferred using the Oxygen Recharge Compressor Assembly (ORCA). There are several drivers that must be considered in managing the available high pressure 02 on the ISS. The amount of O2 the Shuttle can fly up is driven by manifest mass limitations, launch slips, and on orbit Shuttle power requirements. The amount of 02 that is used from the ISS high pressure gas tanks (HPGT) is driven by the number of Shuttle docked and undocked EVAs, the type of EVA prebreath protocol that is used and contingency use of O2 for metabolic support. Also, the use of the ORCA must be managed to optimize its life on orbit and assure that it will be available to transfer the planned amount of O2 from the Shuttle. Management of this resource has required long range planning and coordination between Shuttle manifest on orbit plans. To further optimize the situation hardware options have been pursued.

  17. Modeling and experimental methods to predict oxygen distribution in bone defects following cell transplantation.

    Science.gov (United States)

    Heylman, Christopher M; Santoso, Sharon; Krebs, Melissa D; Saidel, Gerald M; Alsberg, Eben; Muschler, George F

    2014-04-01

    We have developed a mathematical model that allows simulation of oxygen distribution in a bone defect as a tool to explore the likely effects of local changes in cell concentration, defect size or geometry, local oxygen delivery with oxygen-generating biomaterials (OGBs), and changes in the rate of oxygen consumption by cells within a defect. Experimental data for the oxygen release rate from an OGB and the oxygen consumption rate of a transplanted cell population are incorporated into the model. With these data, model simulations allow prediction of spatiotemporal oxygen concentration within a given defect and the sensitivity of oxygen tension to changes in critical variables. This information may help to minimize the number of experiments in animal models that determine the optimal combinations of cells, scaffolds, and OGBs in the design of current and future bone regeneration strategies. Bone marrow-derived nucleated cell data suggest that oxygen consumption is dependent on oxygen concentration. OGB oxygen release is shown to be a time-dependent function that must be measured for accurate simulation. Simulations quantify the dependency of oxygen gradients in an avascular defect on cell concentration, cell oxygen consumption rate, OGB oxygen generation rate, and OGB geometry.

  18. Vented versus unvented chest seals for treatment of pneumothorax and prevention of tension pneumothorax in a swine model.

    Science.gov (United States)

    Kheirabadi, Bijan S; Terrazas, Irasema B; Koller, Alexandra; Allen, Paul B; Klemcke, Harold G; Convertino, Victor A; Dubick, Michael A; Gerhardt, Robert T; Blackbourne, Lorne H

    2013-07-01

    Unvented chest seals (CSs) are currently recommended for the management of penetrating thoracic injuries in the battlefield. Since no supporting data exist, we compared the efficacy of a preferred unvented with that of a vented CS in a novel swine model of pneumothorax (PTx). An open chest wound was created in the left thorax of spontaneously air-breathing anesthetized pigs (n = 8). A CS was applied over the injury, then tension PTx was induced by incremental air injections (0.2 L) into the pleural cavity via a cannula that was also used to measure intrapleural pressure (IP). Both CS were tested on each pig in series. Tidal volume (V(T)), respiratory rate, IP, heart rate, mean arterial pressure, cardiac output, central venous pressure, pulmonary arterial pressure, venous and peripheral oxygen saturations (SvO2, SpO2) were recorded. Tension PTx was defined as a mean IP equal to or greater than +1 mm Hg plus significant (20-30%) deviation in baseline levels of the previously mentioned parameters and confirmed by chest x-ray study. PaO2 and PaCo2 were also measured. PTx produced immediate breathing difficulty and significant rises in IP and pulmonary arterial pressure and falls in V(T), SpO2, and SvO2. Both CSs returned these parameters to near baseline within 5 minutes of application. After vented CS was applied, serial air injections up to 2 L resulted in no significant change in the previously mentioned parameters. After unvented CS application, progressive deterioration of all respiratory parameters and onset of tension PTx were observed in all subjects after approximately 1.4-L air injection. Both vented and unvented CSs provided immediate improvements in breathing and blood oxygenation in our model of penetrating thoracic trauma. However, in the presence of ongoing intrapleural air accumulation, the unvented CS led to tension PTx, hypoxemia, and possible respiratory arrest, while the vented CS prevented these outcomes.

  19. Strain rate effects on reinforcing steels in tension

    Science.gov (United States)

    Cadoni, Ezio; Forni, Daniele

    2015-09-01

    It is unquestionable the fact that a structural system should be able to fulfil the function for which it was created, without being damaged to an extent disproportionate to the cause of damage. In addition, it is an undeniable fact that in reinforced concrete structures under severe dynamic loadings, both concrete and reinforcing bars are subjected to high strain-rates. Although the behavior of the reinforcing steel under high strain rates is of capital importance in the structural assessment under the abovementioned conditions, only the behaviour of concrete has been widely studied. Due to this lack of data on the reinforcing steel under high strain rates, an experimental program on rebar reinforcing steels under high strain rates in tension is running at the DynaMat Laboratory. In this paper a comparison of the behaviour in a wide range of strain-rates of several types of reinforcing steel in tension is presented. Three reinforcing steels, commonly proposed by the European Standards, are compared: B500A, B500B and B500C. Lastly, an evaluation of the most common constitutive laws is performed.

  20. Caregiving, perceptions of maternal favoritism, and tension among siblings.

    Science.gov (United States)

    Suitor, J Jill; Gilligan, Megan; Johnson, Kaitlin; Pillemer, Karl

    2014-08-01

    Studies of later-life families have revealed that sibling tension often increases in response to parents' need for care. Both theory and research on within-family differences suggest that when parents' health declines, sibling relations may be affected by which children assume care and whether siblings perceive that the parent favors some offspring over others. In the present study, we explore the ways in which these factors shape sibling tension both independently and in combination during caregiving. In this article, we use data collected from 450 adult children nested within 214 later-life families in which the offspring reported that their mothers needed care within 2 years prior to the interview. Multilevel analyses demonstrated that providing care and perceiving favoritism regarding future caregiving were associated with sibling tension following mothers' major health events. Further, the effects of caregiving on sibling tension were greater when perceptions of favoritism were also present. These findings shed new light on the conditions under which adult children are likely to experience high levels of sibling tension during caregiving. Understanding these processes is important because siblings are typically the individuals to whom caregivers are most likely to turn for support when assuming care of older parents, yet these relationships are often a major source of interpersonal stress. © The Author 2013. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Effects of whole body UV-irradiation on oxygen delivery from the erythrocyte

    International Nuclear Information System (INIS)

    Humpeler, E.; Mairbaeurl, H.; Hoenigsmann, H.

    1982-01-01

    In 16 healthy caucasian volunteers (mean age: 22.2 years) the influence of whole body UV-irradiation on the oxygen transport properties of erythrocytes was investigated. Four hours after irradiation with UV (using the minimal erythema dose, MED) no variation of haemoglobin concentration, hematocrit, mean corpuscular haemoglobin concentration, pH or standard bicarbonate could be found, whereas inorganic plasma phosphate (Psub(i)), calcium, the intraerythrocytic 2,3-diphosphoglycerate (2,3-DPG), the activity of erythrocytic phosphofructokinase (PFK) and pyruvatekinase (PK) increased significantly. The half saturation tension of oxygen (P 50 -value) tended to increase. The increase of Psub(i) causes - via a stimulation of the glycolytic pathway - an increase in 2,3-DPG concentration and thus results in a shift of the oxygen dissociation curve. It is therefore possible to enhance tissue oxygenation by whole body UV-irradiation. (orig.)

  2. Oxygenation of the traditional and thin-walled MT-YBCO in flowing oxygen and under high evaluated oxygen pressure

    Energy Technology Data Exchange (ETDEWEB)

    Prikhna, Tatiana [Institute for Superhard Materials, 2 Avtozavodskaya Street, Kiev 04074 (Ukraine)], E-mail: prikhna@iptelecom.net.ua; Chaud, Xavier [CNRS/CRETA, 25, Avenue des Martyrs BP 166, 38042 Grenoble, Cedex 9 (France); Gawalek, Wolfgang [Institut fuer Physikalische Hochtechnologie, Albert-Einstein-Strasse 9, Jena (Germany); Rabier, Jaques [Universite de Poitiers, CNRS/Lab. de Metallurgie Physique, UMR 6630 CNRS-Universite de Poitiers SP2MI, BP 30179, F-86962 Chasseneuil Futuroscope Cedex (France); Savchuk, Yaroslav [Institute for Superhard Materials, 2 Avtozavodskaya Street, Kiev 04074 (Ukraine); Joulain, Anne [Universite de Poitiers, CNRS/Lab. de Metallurgie Physique, UMR 6630 CNRS-Universite de Poitiers SP2MI, BP 30179, F-86962 Chasseneuil Futuroscope Cedex (France); Vlasenko, Andrey; Moshchil, Viktor; Sergienko, Nina; Dub, Sergey; Melnikov, Vladimir [Institute for Superhard Materials, 2 Avtozavodskaya Street, Kiev 04074 (Ukraine); Litzkendorf, Doris; Habisreuther, Tobias [Institut fuer Physikalische Hochtechnologie, Albert-Einstein-Strasse 9, Jena (Germany); Sverdun, Vladimir [Institute for Superhard Materials, 2 Avtozavodskaya Street, Kiev 04074 (Ukraine)

    2007-09-01

    The high pressure-high temperature oxygenation of thin-walled MT-YBCO (with artificially produced holes) allows decreasing the amount of macrocracks and increasing j{sub c} of the material. The MT-YBCO produced from Y123 and Y211 in the fields higher than 2 T showed higher j{sub c} in the ab-planes and lower j{sub c} in the c-direction than the MT-YBCO manufactured from Y123 and Y{sub 2}O{sub 3} and can be explained by the difference in twin and microcrack density that in turn can be affected by the difference in Y211 phase distribution.

  3. High-Flow Nasal Interface Improves Oxygenation in Patients Undergoing Bronchoscopy

    Directory of Open Access Journals (Sweden)

    Umberto Lucangelo

    2012-01-01

    Full Text Available During bronchoscopy hypoxemia is commonly found and oxygen supply can be delivered by interfaces fed with high gas flows. Recently, the high-flow nasal cannula (HFNC has been introduced for oxygen therapy in adults, but they have not been used so far during bronchoscopy in adults. Forty-five patients were randomly assigned to 3 groups receiving oxygen: 40 L/min through a Venturi mask (V40, N=15, nasal cannula (N40, N=15, and 60 L/min through a nasal cannula (N60, N=15 during bronchoscopy. Gas exchange and circulatory variables were sampled before (FiO2 = 0.21, at the end of bronchoscopy (FiO2 = 0.5, and thereafter (V40, FiO2 = 0.35. In 8 healthy volunteers oxygen was randomly delivered according to V40, N40, and N60 settings, and airway pressure was measured. At the end of bronchoscopy, N60 presented higher PaO2, PaO2/FiO2, and SpO2 than V40 and N40 that did not differ between them. In the volunteers (N60 median airway pressure amounted to 3.6 cmH2O. Under a flow rate of 40 L/min both the Venturi mask and HFNC behaved similarly, but nasal cannula associated with a 60 L/min flow produced the better results, thus indicating its use in mild respiratory dysfunctions.

  4. Blood transfusion before radiation for malignancies

    International Nuclear Information System (INIS)

    Hunt, T.K.

    1989-01-01

    This editorial discusses the situation of administering blood to patients prior to radiotherapy in an attempt to increase tissue/tumor oxygen tension. The author believes that since the rate at which tumor cells consume oxygen is highly variable, the aim of achieving high cellular oxygen tension may be met better by maintaining a high blood perfusion rate. Blood volume can be maintained without relying on transfusion, and safer alternatives are available

  5. Oxygen influence on ceramics wettability by liquid metals: Ag/{alpha}-Al{sub 2}O{sub 3}-Experiments and modelling

    Energy Technology Data Exchange (ETDEWEB)

    Muolo, M.L.; Valenza, F. [Institute for Energetics and Interphases - IENI CNR, via de Marini 6, 16149 Genova (Italy); Passerone, A. [Institute for Energetics and Interphases - IENI CNR, via de Marini 6, 16149 Genova (Italy)], E-mail: a.passerone@ge.ieni.cnr.it; Passerone, D. [Swiss Federal Lab. for Mater. Testing and Res. (EMPA) - Uberlandstrasse 129, 8600 Duebendorf (Switzerland)

    2008-11-15

    A renewed interest in the effects of oxygen on the wetting of solid oxides has recently risen in connection to the development of the technique of 'air brazing' which makes use of the strong effect of oxygen to increase the wettability of oxides by means of processes running in air or in atmospheres with high oxygen content. Adsorption of oxygen not only at the liquid-vapour surface but also at the solid-liquid interface has been postulated by many previous researches, mainly on the basis of thermodynamic considerations. Along the same line, new results of the wetting behaviour in the system Ag/{alpha}-Al{sub 2}O{sub 3} as a function of oxygen partial pressure are presented, with the simultaneous measurement of the liquid surface tension. These results are compared with the existing ones, and discussed on the basis of thermodynamic principles. The resulting work of adhesion is compared with the 'work of separation' computed by the density functional theory (DFT) approach. DFT calculations are also employed, at variance with previous models, to investigate the structures that are formed at the interface upon addition of oxygen in different sites energetics, atomic and electronic properties of this oxygen-rich interface are discussed together with the connection with experiments.

  6. Width and string tension of the flux tube in SU(2) lattice gauge theory at high temperature

    Science.gov (United States)

    Chagdaa, S.; Galsandorj, E.; Laermann, E.; Purev, B.

    2018-02-01

    We study the profiles of the flux tube between a static quark and an antiquark in quenched SU(2) lattice gauge theory at temperatures around the deconfinement phase transition. The physical width of the flux tube and the string tension have been determined from the transverse profiles and the q\\bar{q} potential, respectively. Exploiting the computational power of a GPU accelerator in our flux tube investigation, we achieve much higher statistics through which we can increase the signal to noise ratio of our observables in the simulation. This has allowed the investigation of larger lattices as well as larger separations between the quarks than in our previous work. The improved accuracy gives us better results for the width and the string tension. The physical width of the flux tube increases with the temperature up to around T c while keeping its increasing dependence on the q\\bar{q} separation. The string tension results are compared for two different sizes of the lattice. As the lattice becomes larger and finer together with the improved precision, the temperature dependent string tension tends to have a smaller value than the previous one.

  7. Influence of oxygen levels on chondrogenesis of porcine mesenchymal stem cells cultured in polycaprolactone scaffolds.

    Science.gov (United States)

    Rodenas-Rochina, Joaquin; Kelly, Daniel J; Gómez Ribelles, Jose Luis; Lebourg, Myriam

    2017-06-01

    Chondrogenesis of mesenchymal stem cells (MSCs) is known to be regulated by a number of environmental factors, including local oxygen levels. The hypothesis of this study is that the response of MSCs to hypoxia is dependent on the physical and chemical characteristics of the substrate used. The objective of this study was to explore how different modifications to polycaprolactone (PCL) scaffolds influenced the response of MSCs to hypoxia. PCL, PCL-hyaluronic acid (HA), and PCL-Bioglass ® (BG) scaffolds were seeded with MSCs derived from bone marrow and cultured for 35 days under normoxic or low oxygen conditions, and the resulting biochemical properties of the MSC laden construct were assessed. Low oxygen tension has a positive effect over cell proliferation and macromolecules biosynthesis. Furthermore, hypoxia enhanced the distribution of collagen and glycosaminoglycans (GAGs) deposition through the scaffold. On the other hand, MSCs displayed certain material dependent responses to hypoxia. Low oxygen tension had a positive effect on cell proliferation in BG and HA scaffolds, but only a positive effect on GAGs synthesis in PCL and HA scaffolds. In conclusion, hypoxia increased cell viability and expression of chondrogenic markers but the cell response was modulated by the type of scaffold used. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 1684-1691, 2017. © 2017 Wiley Periodicals, Inc.

  8. Oxygen stoichiometry and the high Tc superconducting oxides

    International Nuclear Information System (INIS)

    Tarascon, J.M.; Bagley, B.G.

    1989-01-01

    Methods for determining the oxygen content in high Tc materials, such as thermogravimetric analysis and chemical analysis, are discussed. Consideration is given to La-based cuprates, Y-based cuprates, and Bi-based cuprates. Superconducting transition temperatures are analyzed as a function of the Cu(1)-O(4) bond lengths for several different compositions in the Y-based system. 28 references

  9. Urinary incontinence - tension-free vaginal tape

    Science.gov (United States)

    ... ency/article/007377.htm Urinary incontinence - tension-free vaginal tape To use the sharing features on this page, please enable JavaScript. Placement of tension-free vaginal tape is surgery to help control stress urinary ...

  10. Effect of a High-intensity Interval Training method on maximum oxygen consumption in Chilean schoolchildren

    Directory of Open Access Journals (Sweden)

    Sergio Galdames-Maliqueo

    2017-12-01

    Full Text Available Introduction: The low levels of maximum oxygen consumption (VO2max evaluated in Chilean schoolchildren suggest the startup of trainings that improve the aerobic capacity. Objective: To analyze the effect of a High-intensity Interval Training method on maximum oxygen consumption in Chilean schoolchildren. Materials and methods: Thirty-two high school students from the eighth grade, who were divided into two groups, were part of the study (experimental group = 16 students and control group = 16 students. The main analyzed variable was the maximum oxygen consumption through the Course Navette Test. A High-intensity Interval training method was applied based on the maximum aerobic speed obtained through the Test. A mixed ANOVA was used for statistical analysis. Results: The experimental group showed a significant increase in the Maximum Oxygen Consumption between the pretest and posttest when compared with the control group (p < 0.0001. Conclusion: The results of the study showed a positive effect of the High-intensity Interval Training on the maximum consumption of oxygen. At the end of the study, it is concluded that High-intensity Interval Training is a good stimulation methodology for Chilean schoolchildren.

  11. Bosch Reactor Development for High Percentage Oxygen Recovery from Carbon Dioxide

    Science.gov (United States)

    Howard, David; Abney, Morgan

    2015-01-01

    This next Generation Life Support Project entails the development and demonstration of Bosch reaction technologies to improve oxygen recovery from metabolically generated oxygen and/or space environments. A primary focus was placed on alternate carbon formation reactor concepts to improve useful catalyst life for space vehicle applications, and make use of in situ catalyst resources for non-terrestrial surface missions. Current state-of-the-art oxygen recovery systems onboard the International Space Station are able to effectively recover approximately 45 percent of the oxygen consumed by humans and exhausted in the form of carbon dioxide (CO2). Excess CO2 is vented overboard and the oxygen contained in the molecules is lost. For long-duration missions beyond the reaches of Earth for resupply, it will be necessary to recover greater amounts of constituents such as oxygen that are necessary for sustaining life. Bosch technologies theoretically recover 100 percent of the oxygen from CO2, producing pure carbon as the sole waste product. Challenges with this technology revolve around the carbon product fouling catalyst materials, drastically limiting catalyst life. This project successfully demonstrated techniques to extend catalyst surface area exposure times to improve catalyst life for vehicle applications, and demonstrated the use of Martian and lunar regolith as viable catalyst Bosch Reactor Development for High Percentage Oxygen Recovery From Carbon Dioxide materials for surface missions. The Bosch process generates carbon nanotube formation within the regolith, which has been shown to improve mechanical properties of building materials. Production of bricks from post reaction regolith for building and radiation shielding applications were also explored.

  12. Uncovering behavioural diversity amongst high-strength Pseudomonas spp. surfactants at the limit of liquid surface tension reduction.

    Science.gov (United States)

    Kabir, Kamaluddeen; Deeni, Yusuf Y; Hapca, Simona M; Moore, Luke; Spiers, Andrew J

    2018-02-01

    Bacterial biosurfactants have a wide range of biological functions and biotechnological applications. Previous analyses had suggested a limit to their reduction of aqueous liquid surface tensions (γMin), and here we confirm this in an analysis of 25 Pseudomonas spp. strains isolated from soil which produce high-strength surfactants that reduce surface tensions to 25.2 ± 0.1-26.5 ± 0.2 mN m-1 (the surface tension of sterile growth medium and pure water was 52.9 ± 0.4 mN m-1 and 72.1 ± 1.2 mN m-1, respectively). Comparisons of culture supernatants produced using different growth media and semi-purified samples indicate that the limit of 24.2-24.7 mN m-1 is not greatly influenced by culture conditions, pH or NaCl concentrations. We have used foam, emulsion and oil-displacement behavioural assays as a simple and cost-effective proxy for in-depth biochemical characterisation, and these suggest that there is significant structural diversity amongst these surfactants that may reflect different biological functions and offer new biotechnological opportunities. Finally, we obtained a draft genome for the strain producing the highest strength surfactant, and identified a cluster of non-ribosomal protein synthase genes that may produce a cyclic lipopeptide (CLP)-like surfactant. Further investigation of this group of related bacteria recovered from the same site will allow a better understanding of the significance of the great variety of surfactants produced by bacterial communities found in soil and elsewhere. © FEMS 2018. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. Mixed oxygen ion/electron-conducting ceramics for oxygen separation

    Energy Technology Data Exchange (ETDEWEB)

    Stevenson, J.W.; Armstrong, T.R.; Armstrong, B.L. [Pacific Northwest National Lab., Richland, WA (United States)

    1996-08-01

    Mixed oxygen ion and electron-conducting ceramics are unique materials that can passively separate high purity oxygen from air. Oxygen ions move through a fully dense ceramic in response to an oxygen concentration gradient, charge-compensated by an electron flux in the opposite direction. Compositions in the system La{sub 1{minus}x}M{sub x}Co{sub 1{minus}y{minus}z}Fe{sub y}N{sub z}O{sub 3{minus}{delta}}, perovskites where M=Sr, Ca, and Ba, and N=Mn, Ni, Cu, Ti, and Al, have been prepared and their electrical, oxygen permeation, oxygen vacancy equilibria, and catalytic properties evaluated. Tubular forms, disks, and asymmetric membrane structures, a thin dense layer on a porous support of the same composition, have been fabricated for testing purposes. In an oxygen partial gradient, the passive oxygen flux through fully dense structures was highly dependent on composition. An increase in oxygen permeation with increased temperature is attributed to both enhanced oxygen vacancy mobility and higher vacancy populations. Highly acceptor-doped compositions resulted in oxygen ion mobilities more than an order of magnitude higher than yttria-stabilized zirconia. The mixed conducting ceramics have been utilized in a membrane reactor configuration to upgrade methane to ethane and ethylene. Conditions were established to balance selectivity and throughput in a catalytic membrane reactor constructed from mixed conducting ceramics.

  14. Damage development in woven fabric composites during tension-tension fatigue

    DEFF Research Database (Denmark)

    Hansen, U.

    1999-01-01

    of the operating fatigue damage mechanism(s). Fatigue leads to a degradation of material properties. Consequently, in connection with impact induced local stress raisers, fatigue produces continuously changing non-uniform stress fields because of stress redistribution effects. Other models addressing evolution...... of fatigue damage in composite materials have not been able to simulate evolving nonuniform stress fields. Therefore. in the second part of this paper, an analytical/numerical approach capable of addressing these issues is also proposed.......Impacted woven fabric composites were tested in tension-tension fatigue. In contrast to results from static testing, the effects of low energy impact damage in a fatigue environment were found to be the critical element leading to failure of the specimen. This difference emphasizes the need...

  15. Search for Fractionally Charged Nuclei in High-Energy Oxygen-Lead Collisions

    CERN Multimedia

    2002-01-01

    We propose to use stacks of CR-39 plastic track detectors to look for fractionally charged projectile fragments produced in collisions of high-energy oxygen, sulfur, and calcium nuclei with a lead target. The expected charge resolution is @s^z~=~0.06e for fragments with 17e/3~@$<$~Z~@$<$~23e/3. We request that two target + stack assemblies be exposed to 1~x~10|5 oxygen nuclei at maximum available energy.

  16. Speaker and Observer Perceptions of Physical Tension during Stuttering.

    Science.gov (United States)

    Tichenor, Seth; Leslie, Paula; Shaiman, Susan; Yaruss, J Scott

    2017-01-01

    Speech-language pathologists routinely assess physical tension during evaluation of those who stutter. If speakers experience tension that is not visible to clinicians, then judgments of severity may be inaccurate. This study addressed this potential discrepancy by comparing judgments of tension by people who stutter and expert clinicians to determine if clinicians could accurately identify the speakers' experience of physical tension. Ten adults who stutter were audio-video recorded in two speaking samples. Two board-certified specialists in fluency evaluated the samples using the Stuttering Severity Instrument-4 and a checklist adapted for this study. Speakers rated their tension using the same forms, and then discussed their experiences in a qualitative interview so that themes related to physical tension could be identified. The degree of tension reported by speakers was higher than that observed by specialists. Tension in parts of the body that were less visible to the observer (chest, abdomen, throat) was reported more by speakers than by specialists. The thematic analysis revealed that speakers' experience of tension changes over time and that these changes may be related to speakers' acceptance of stuttering. The lack of agreement between speaker and specialist perceptions of tension suggests that using self-reports is a necessary component for supporting the accurate diagnosis of tension in stuttering. © 2018 S. Karger AG, Basel.

  17. Robust Tensioned Kevlar Suspension Design

    Science.gov (United States)

    Young, Joseph B.; Naylor, Bret J.; Holmes, Warren A.

    2012-01-01

    One common but challenging problem in cryogenic engineering is to produce a mount that has excellent thermal isolation but is also rigid. Such mounts can be achieved by suspending the load from a network of fibers or strings held in tension. Kevlar fibers are often used for this purpose owing to their high strength and low thermal conductivity. A suite of compact design elements has been developed to improve the reliability of suspension systems made of Kevlar.

  18. Sensitivity study of tensions in distribution networks with respect to injected powers

    International Nuclear Information System (INIS)

    Tencio Alfaro, Ernie Fernando

    2013-01-01

    A study of the sensitivity of tension is submitted to small changes of active and reactive power of distributed generators (DG) of a 11 kV radial system of 8 circuits with 75 rods, in which 22 bars with DG and 38 bars with loads. The sensitivities are obtained for 6 load models 3 relations R / X of the lines interconnecting the distributed system, 3 equivalents of Thevenin and high load conditions with low generation and low load with high part of the DG and bars load. The study has obtained to determine which operating conditions of the system have presented the greatest tension sensitivities. A description of the theory of modeling loads and motor is developed for electrical power systems. The several ways to obtain the sensitivity matrix of tension are explained as central axis. (author) [es

  19. Density functional theory of simple polymers in a slit pore. III. Surface tension

    International Nuclear Information System (INIS)

    Hooper, Justin B.; McCoy, John D.; Curro, John G.; Swol, Frank van

    2000-01-01

    In a previous study of tangent hard-site chains near a surface, the inhomogeneous density profiles were found through density functional theory. In the current study, the surface tensions of these systems are found from the results of the previous study through a thermodynamic integration. The calculated surface tensions are then compared to those found directly through computer simulation. Both the surface tension and surface excess for polymeric systems are shown to differ qualitatively from those of atomic systems, although certain similarities are seen at high densities. (c) 2000 American Institute of Physics

  20. Oxygen tension in human tumours measured with polarographic needle electrodes and its relationship to vascular density, necrosis and hypoxia

    International Nuclear Information System (INIS)

    Lyng, Heidi; Sundfoer, Kolbein; Rofstad, Einar K.

    1997-01-01

    Background and purpose: The use of polarographic needle electrodes for measurement of oxygen tension (pO 2 ) in tumours requires documentation of the validity of the method. In the present work the pO 2 values measured polarographically with the Eppendorf pO 2 histograph in human tumours were compared with the histological appearance of the tumour tissue, i.e. vascular density, fraction of necrosis and fraction of hypoxic tissue, to investigate whether the measurements reflected the expected pO 2 . Materials and methods: The pO 2 was measured in cervix tumours in patients and in human melanoma xenografted tumours in athymic mice. Vascular density was determined in the cervix tumours by histological analysis of biopsies from the pO 2 measurement tracks. Fraction of necrosis and fraction of hypoxic tissue, i.e. tissue binding the hypoxia marker pimonidazole, were determined in the melanomas by analysis of histological sections from the tumour planes in which the pO 2 measurements were performed. Results: The pO 2 distributions showed large intratumour heterogeneity. In cervix tumours, tumour regions with vascular density (vascular length per unit tissue volume) in the range of 47-77 mm/mm 3 showed higher pO 2 than tumour regions with vascular density in the range of 20-47 mm/mm 3 , which in turn showed higher pO 2 than tumour regions with vascular density in the range of 0-20 mm/mm 3 . In melanomas, tumour regions in which necrosis and hypoxia constituted more than 50% of the tissue showed lower pO 2 than other tumour regions. Conclusions: The pO 2 measured in the tumours was consistent with the histological appearance of the tissue in which the measurements were performed, suggesting that reliable pO 2 distributions of tumours can be obtained with polarographic needle electrodes

  1. Vacuum phase transition solves the H0 tension

    Science.gov (United States)

    Di Valentino, Eleonora; Linder, Eric V.; Melchiorri, Alessandro

    2018-02-01

    Taking the Planck cosmic microwave background data and the more direct Hubble constant measurement data as unaffected by systematic offsets, the values of the Hubble constant H0 interpreted within the Λ CDM cosmological constant and cold dark matter cosmological model are in ˜3.3 σ tension. We show that the Parker vacuum metamorphosis (VM) model, physically motivated by quantum gravitational effects and with the same number of parameters as Λ CDM , can remove the H0 tension and can give an improved fit to data (up to a mean Δ χ2=-7.5 ). It also ameliorates tensions with weak lensing data and the high redshift Lyman alpha forest data. Considering Bayesian evidence, we found in the case of the Planck data set alone positive evidence for a VM model against a cosmological constant both in the six- and nine-parameter framework. When the R16 data set is also considered, we found a strong evidence for the VM model against a cosmological constant in nine-parameter space. We separately consider a scale-dependent scaling of the gravitational lensing amplitude, such as provided by modified gravity, neutrino mass, or cold dark energy, motivated by the somewhat different cosmological parameter estimates for low and high CMB multipoles. We find that no such scale dependence is preferred.

  2. No oxygen delivery limitation in hepatic encephalopathy

    DEFF Research Database (Denmark)

    Gjedde, Albert; Keiding, Susanne; Vilstrup, Hendrik

    2010-01-01

    to choose between cause and effect in three groups of volunteers, including healthy control subjects (HC), patients with cirrhosis of the liver without hepatic encephalopathy (CL), and patients with cirrhosis with acute hepatic encephalopathy. Compared to HC subjects, blood flow and energy metabolism had......Hepatic encephalopathy is a condition of reduced brain functioning in which both blood flow and brain energy metabolism declined. It is not known whether blood flow or metabolism is the primary limiting factor of brain function in this condition. We used calculations of mitochondrial oxygen tension...

  3. Parenteral treatment of episodic tension-type headache: a systematic review.

    Science.gov (United States)

    Weinman, Danielle; Nicastro, Olivia; Akala, Olabiyi; Friedman, Benjamin W

    2014-02-01

    Tension-type headache is highly prevalent in the general population and is a consistent if not frequent cause of visits to acute care settings. Analgesics such as nonsteroidal anti-inflammatory drugs, acetaminophen, and salicylates are considered first-line therapy for treatment of tension-type headache. For patients who present to an acute care setting with persistent tension-type headache despite analgesic therapy, it is not clear which parenteral agent should be administered. We performed a systematic review of the medical literature to determine whether parenteral therapies other than salicylates or nonsteroidals are efficacious for acute tension-type headache. We performed a systematic review of Medline, EMBASE, CINAHL, Google scholar, and the Cochrane Central Registry of Controlled Trials from inception through August, 2012 using the search terms "tension-type headache" and "parenteral or subcutaneous or intramuscular or intravenous." Our goal was to identify randomized trials in which one parenteral treatment was compared to another active comparator or to placebo for the acute relief of tension-type headache. Parenteral was defined as intravenous, intramuscular, or subcutaneous administration. We only included studies that distinguished tension-type headache from other primary headache disorders, such as migraine. The primary outcome for this review was measures of efficacy one hour after medication administration. Data abstraction was performed by two authors. Disagreements were resolved by a third author. We assessed the internal validity of trials using the Cochrane Collaboration risk of bias tool. Because of the small number of trials identified, and the substantial heterogeneity among study design and medications, we decided that combining data and reporting summary statistics would serve no useful function. The results of individual studies are presented using Number Needed to Treat (NNT) with 95%CI when dichotomous outcomes were available and

  4. Depression, automatic thoughts, alexithymia, and assertiveness in patients with tension-type headache.

    Science.gov (United States)

    Yücel, Basak; Kora, Kaan; Ozyalçín, Süleyman; Alçalar, Nilüfer; Ozdemir, Ozay; Yücel, Aysen

    2002-03-01

    The role of psychological factors related to headache has long been a focus of investigation. The aim of this study was to evaluate depression, automatic thoughts, alexithymia, and assertiveness in persons with tension-type headache and to compare the results with those from healthy controls. One hundred five subjects with tension-type headache (according to the criteria of the International Headache Society classification) and 70 controls were studied. The Beck Depression Inventory, Automatic Thoughts Scale, Toronto Alexithymia Scale, and Rathus Assertiveness Schedule were administered to both groups. Sociodemographic variables and headache features were evaluated via a semistructured scale. Compared with healthy controls, the subjects with headache had significantly higher scores on measures of depression, automatic thoughts, and alexithymia and lower scores on assertiveness. Subjects with chronic tension-type headache had higher depression and automatic thoughts scores than those with episodic tension-type headache. These findings suggested that persons with tension-type headache have high depression scores and also may have difficulty with expression of their emotions. Headache frequency appears to influence the likelihood of coexisting depression.

  5. Force generation and temperature-jump and length-jump tension transients in muscle fibers.

    Science.gov (United States)

    Davis, J S; Rodgers, M E

    1995-01-01

    Muscle tension rises with increasing temperature. The kinetics that govern the tension rise of maximally Ca(2+)-activated, skinned rabbit psoas fibers over a temperature range of 0-30 degrees C was characterized in laser temperature-jump experiments. The kinetic response is simple and can be readily interpreted in terms of a basic three-step mechanism of contraction, which includes a temperature-sensitive rapid preequilibrium(a) linked to a temperature-insensitive rate-limiting step and followed by a temperature-sensitive tension-generating step. These data and mechanism are compared and contrasted with the more complex length-jump Huxley-Simmons phases in which all states that generate tension or bear tension are perturbed. The rate of the Huxley-Simmons phase 4 is temperature sensitive at low temperatures but plateaus at high temperatures, indicating a change in rate-limiting step from a temperature-sensitive (phase 4a) to a temperature-insensitive reaction (phase 4b); the latter appears to correlate with the slow, temperature-insensitive temperature-jump relaxation. Phase 3 is absent in the temperature-jump, which excludes it from tension generation. We confirm that de novo tension generation occurs as an order-disorder transition during phase 2slow and the equivalent, temperature-sensitive temperature-jump relaxation. PMID:7612845

  6. Highly Selective TiN-Supported Highly Dispersed Pt Catalyst: Ultra Active toward Hydrogen Oxidation and Inactive toward Oxygen Reduction.

    Science.gov (United States)

    Luo, Junming; Tang, Haibo; Tian, Xinlong; Hou, Sanying; Li, Xiuhua; Du, Li; Liao, Shijun

    2018-01-31

    The severe dissolution of the cathode catalyst, caused by an undesired oxygen reduction reaction at the anode during startup and shutdown, is a fatal challenge to practical applications of polymer electrolyte membrane fuel cells. To address this important issue, according to the distinct structure-sensitivity between the σ-type bond in H 2 and the π-type bond in O 2 , we design a HD-Pt/TiN material by highly dispersing Pt on the TiN surface to inhibit the unwanted oxygen reduction reaction. The highly dispersed Pt/TiN catalyst exhibits excellent selectivity toward hydrogen oxidation and oxygen reduction reactions. With a Pt loading of 0.88 wt %, our catalyst shows excellent hydrogen oxidation reaction activity, close to that of commercial 20 wt % Pt/C catalyst, and much lower oxygen reduction reaction activity than the commercial 20 wt % Pt/C catalyst. The lack of well-ordered Pt facets is responsible for the excellent selectivity of the HD-Pt/TiN materials toward hydrogen oxidation and oxygen reduction reactions. Our work provides a new and cost-effective solution to design selective catalysts toward hydrogen oxidation and oxygen reduction reactions, making the strategy of using oxygen-tolerant anode catalyst to improve the stability of polymer electrolyte membrane fuel cells during startup and shutdown more affordable and practical.

  7. Direct measurement of local oxygen concentration in the bone marrow of live animals

    Science.gov (United States)

    Spencer, Joel A.; Ferraro, Francesca; Roussakis, Emmanuel; Klein, Alyssa; Wu, Juwell; Runnels, Judith M.; Zaher, Walid; Mortensen, Luke J.; Alt, Clemens; Turcotte, Raphaël; Yusuf, Rushdia; Côté, Daniel; Vinogradov, Sergei A.; Scadden, David T.; Lin, Charles P.

    2014-04-01

    Characterization of how the microenvironment, or niche, regulates stem cell activity is central to understanding stem cell biology and to developing strategies for the therapeutic manipulation of stem cells. Low oxygen tension (hypoxia) is commonly thought to be a shared niche characteristic in maintaining quiescence in multiple stem cell types. However, support for the existence of a hypoxic niche has largely come from indirect evidence such as proteomic analysis, expression of hypoxia inducible factor-1α (Hif-1α) and related genes, and staining with surrogate hypoxic markers (for example, pimonidazole). Here we perform direct in vivo measurements of local oxygen tension (pO2) in the bone marrow of live mice. Using two-photon phosphorescence lifetime microscopy, we determined the absolute pO2 of the bone marrow to be quite low (hypoxic as it is perfused with small arteries that are often positive for the marker nestin. These pO2 values change markedly after radiation and chemotherapy, pointing to the role of stress in altering the stem cell metabolic microenvironment.

  8. Oxygen tension in transplanted mouse osteosarcomas during fractionated high-LET- and low-LET radiotherapy - predictive aspects for choosing beam quality?

    International Nuclear Information System (INIS)

    Auberger, T.; Thuerriegel, B.; Freude, T.; Weissfloch, L.; Kneschaurek, P.; Molls, M.; Senekowitsch-Schmidtke, R.; Wagner, F.M.

    1999-01-01

    Murine OTS64 - osteosarcomas were tranplanted in 102 balb-C mice and irradiated by 36 Gy of photons in fractions of 3 Gy five times a week (group P-36/3) or by 12 Gy of reactor fission neutrons in fractions of 2 Gy two times a week (group N-12/2). Irradiations started at a tumor volume of 500 to 600 mm 3 . A third group received no radiotherapy, but all investigations (group CG). Tumor volume and tumor oxygenation were measured once a week under therapy and during three weeks after therapy. For in vivo-evaluation of oxygen status a computerized polarographic needle electrode system (KIMOC pO 2 histograph, Eppendorf) was used. The median pO 2 and the hypoxic fraction (pO 2 values 2 decreased from 20 mm to 8 mm Hg and the hypoxic fraction increased from 7% to 31%. After fractionated photon therapy a growth delay of three weeks was observed. Six weeks after beginning of the irradiation the median tumor volume had been doubled again. After fission neutron therapy growth delay continued until the end of the follow-up period. In both of the irradiated groups a significant decrease of median pO 2 values and an increase of the hypoxic fraction were observed under radiotherapy. Hypoxia was more intensive after neutrons with a decrease of the median pO 2 from 20 mm Hg to 1 mm Hg vs. 10 mm Hg after photon therapy and with an increase of the hypoxic fraction from 7% to 78% vs. 36% respectively. Two weeks after the end of therapy the median pO 2 and the hypoxic fraction of both treated groups reached the levels prior to irradiation indicating a complete reoxygenation. (orig.)

  9. The influence of high-heeled shoes on strain and tension force of the anterior talofibular ligament and plantar fascia during balanced standing and walking.

    Science.gov (United States)

    Yu, Jia; Wong, Duo Wai-Chi; Zhang, Hongtao; Luo, Zong-Ping; Zhang, Ming

    2016-10-01

    High-heeled shoes have the capability to alter the strain and tension of ligamentous structures between the foot and ankle, which may result in ankle instability. However, high-heeled shoes can also reduce the strain on plantar fascia, which may be beneficial for the treatment of plantar fasciitis. In this study, the influence of heel height on strain and tension force applied to the anterior talofibular ligament (ATL) and plantar fascia were investigated. A three-dimensional finite element model of coupled foot-ankle-shoe complex was constructed. Four heel heights were studied in balanced standing: 0 in. (0cm), 1 in. (2.54cm), 2 in. (5.08cm), and 3 in. (7.62cm). A walking analysis was performed using 2-in. (5.08cm) high-heeled shoes. During balanced standing, the tension force on the ATL increased from 14.8N to 97.0N, with a six-fold increase in strain from 0 in. to 3 in. (0-7.62cm). The tension force and the average strain on the plantar fascia decreased from 151.0N (strain: 0.74%) to 59.6N (strain: 0.28%) when the heel height increased from 0 in. to 2 in. (0-5.08cm). When heel height reached 3 in. (7.62cm), the force and average strain increased to 278.3N (strain: 1.33%). The walking simulation showed that the fascia stretched out while the ATL loading decreased during push off. The simulation outcome demonstrated the influence of heel height on ATL alteration and plantar fascia strain, which implies risks for ankle injury and suggests guidance for the treatment of plantar fasciitis. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Assessment and reduction of diaphragmatic tension during hiatal hernia repair.

    Science.gov (United States)

    Bradley, Daniel Davila; Louie, Brian E; Farivar, Alexander S; Wilshire, Candice L; Baik, Peter U; Aye, Ralph W

    2015-04-01

    During hiatal hernia repair there are two vectors of tension: axial and radial. An optimal repair minimizes the tension along these vectors. Radial tension is not easily recognized. There are no simple maneuvers like measuring length that facilitate assessment of radial tension. The aims of this project were to: (1) establish a simple intraoperative method to evaluate baseline tension of the diaphragmatic hiatal muscle closure; and, (2) assess if tension is reduced by relaxing maneuvers and if so, to what degree. Diaphragmatic characteristics and tension were assessed during hiatal hernia repair with a tension gage. We compared tension measured after hiatal dissection and after relaxing maneuvers were performed. Sixty-four patients (29 M:35F) underwent laparoscopic hiatal hernia repair. Baseline hiatal width was 2.84 cm and tension 13.6 dag. There was a positive correlation between hiatal width and tension (r = 0.55) but the strength of association was low (r (2) = 0.31). Four different hiatal shapes (slit, teardrop, "D", and oval) were identified and appear to influence tension and the need for relaxing incision. Tension was reduced by 35.8 % after a left pleurotomy (12 patients); by 46.2 % after a right crural relaxing incision (15 patients); and by 56.1 % if both maneuvers were performed (6 patients). Tension on the diaphragmatic hiatus can be measured with a novel device. There was a limited correlation with width of the hiatal opening. Relaxing maneuvers such as a left pleurotomy or a right crural relaxing incision reduced tension. Longer term follow-up will determine whether outcomes are improved by quantifying and reducing radial tension.

  11. High-voltage-powered transistorized preamplifier; Pre-amplificateur transistorise avec alimentation haute tension; Vysokovol'tnyj ehnergeticheskij predvaritel'nyj usilitel' na tranzistorakh; Preamplificador transistorizado alimentado con alta tension

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Jr, W E; Wakefield, A W [University of Washington, Seattle, WA (United States)

    1962-04-15

    One of the problems that is frequently met in the field of nuclear electronics is that of coupling the signal from a high-impedance pulse-type radiation detector to a low-impedance transmission line. Radiation detectors and their associated counting equipment are often separated by a considerable distance and some efficient means of transmitting the signal from the detector to the counting system must be provided. In practice, a low-impedance coaxial cable is used for the transmission line and a cathode-follower or emitter-follower circuit is used to achieve the required impedance match. This paper describes a unique emitter-follower circuit that has been utilized very successfully at the University of Washington. The emitter-follower circuit is unique in that power for the transistor circuit is derived from the high voltage that is supplied to the radiation detector. The two pnp alloy-junction transistors employed in the preamplifier yield.a voltage gain of unity over a dynamic range of from 1 mV to 5 V. Stabilization of the operating voltage for the emitter-follower circuit is provided by a small zener diode. The current drain of a typical remote-scintillation detector employing the circuit ranges from 0.35 to 0.65 mA when the high voltage is supplied to the scintillation detector is varied from 800 to 1 500 V. The unit will drive 500 ft of 52-{Omega} coaxial line with a 25% loss in pulse amplitude and has been used with remotely operated scintillation-type detectors and BF{sub 3}-type neutron detectors with excellent results. (author) [French] Un des problemes qui se posent frequemment en electronique nucleaire est celui de l'adaptation d'un detecteur d'impulsions a grande impedance a une ligne de transmission a basse impedance. La difficulte est la suivante: les detecteurs etant souvent sensiblement eloignes des appareils de comptage connexes, il faut prevoir un moyen efficace de transmettre le signal du detecteur au dispositif de comptage. En pratique, on

  12. Formation of SIMOX–SOI structure by high-temperature oxygen implantation

    International Nuclear Information System (INIS)

    Hoshino, Yasushi; Kamikawa, Tomohiro; Nakata, Jyoji

    2015-01-01

    We have performed oxygen ion implantation in silicon at very high substrate-temperatures (⩽1000 °C) for the purpose of forming silicon-on-insulator (SOI) structure. We have expected that the high-temperature implantation can effectively avoids ion-beam-induced damages in the SOI layer and simultaneously stabilizes the buried oxide (BOX) and SOI-Si layer. Such a high-temperature implantation makes it possible to reduce the post-implantation annealing temperature. In the present study, oxygen ions with 180 keV are incident on Si(0 0 1) substrates at various temperatures from room temperature (RT) up to 1000 °C. The ion-fluencies are in order of 10"1"7–10"1"8 ions/cm"2. Samples have been analyzed by atomic force microscope, Rutherford backscattering, and micro-Raman spectroscopy. It is found in the AFM analysis that the surface roughness of the samples implanted at 500 °C or below are significantly small with mean roughness of less than 1 nm, and gradually increased for the 800 °C-implanted sample. On the other hand, a lot of dents are observed for the 1000 °C-implanted sample. RBS analysis has revealed that stoichiometric SOI-Si and BOX-SiO_2 layers are formed by oxygen implantation at the substrate temperatures of RT, 500, and 800 °C. However, SiO_2-BOX layer has been desorbed during the implantation. Raman spectra shows that the ion-beam-induced damages are fairly suppressed by such a high-temperatures implantation.

  13. Density and surface tension of ionic liquids.

    Science.gov (United States)

    Kolbeck, C; Lehmann, J; Lovelock, K R J; Cremer, T; Paape, N; Wasserscheid, P; Fröba, A P; Maier, F; Steinrück, H-P

    2010-12-30

    We measured the density and surface tension of 9 bis[(trifluoromethyl)sulfonyl]imide ([Tf(2)N](-))-based and 12 1-methyl-3-octylimidazolium ([C(8)C(1)Im](+))-based ionic liquids (ILs) with the vibrating tube and the pendant drop method, respectively. This comprehensive set of ILs was chosen to probe the influence of the cations and anions on density and surface tension. When the alkyl chain length in the [C(n)C(1)Im][Tf(2)N] series (n = 1, 2, 4, 6, 8, 10, 12) is increased, a decrease in density is observed. The surface tension initially also decreases but reaches a plateau for alkyl chain lengths greater than n = 8. Functionalizing the alkyl chains with ethylene glycol groups results in a higher density as well as a higher surface tension. For the dependence of density and surface tension on the chemical nature of the anion, relations are only found for subgroups of the studied ILs. Density and surface tension values are discussed with respect to intermolecular interactions and surface composition as determined by angle-resolved X-ray photoelectron spectroscopy (ARXPS). The absence of nonvolatile surface-active contaminants was proven by ARXPS.

  14. MR Imaging-derived Oxygen-Hemoglobin Dissociation Curves and Fetal-Placental Oxygen-Hemoglobin Affinities.

    Science.gov (United States)

    Avni, Reut; Golani, Ofra; Akselrod-Ballin, Ayelet; Cohen, Yonni; Biton, Inbal; Garbow, Joel R; Neeman, Michal

    2016-07-01

    Purpose To generate magnetic resonance (MR) imaging-derived, oxygen-hemoglobin dissociation curves and to map fetal-placental oxygen-hemoglobin affinity in pregnant mice noninvasively by combining blood oxygen level-dependent (BOLD) T2* and oxygen-weighted T1 contrast mechanisms under different respiration challenges. Materials and Methods All procedures were approved by the Weizmann Institutional Animal Care and Use Committee. Pregnant mice were analyzed with MR imaging at 9.4 T on embryonic days 14.5 (eight dams and 58 fetuses; imprinting control region ICR strain) and 17.5 (21 dams and 158 fetuses) under respiration challenges ranging from hyperoxia to hypoxia (10 levels of oxygenation, 100%-10%; total imaging time, 100 minutes). A shorter protocol with normoxia to hyperoxia was also performed (five levels of oxygenation, 20%-100%; total imaging time, 60 minutes). Fast spin-echo anatomic images were obtained, followed by sequential acquisition of three-dimensional gradient-echo T2*- and T1-weighted images. Automated registration was applied to align regions of interest of the entire placenta, fetal liver, and maternal liver. Results were compared by using a two-tailed unpaired Student t test. R1 and R2* values were derived for each tissue. MR imaging-based oxygen-hemoglobin dissociation curves were constructed by nonlinear least square fitting of 1 minus the change in R2*divided by R2*at baseline as a function of R1 to a sigmoid-shaped curve. The apparent P50 (oxygen tension at which hemoglobin is 50% saturated) value was derived from the curves, calculated as the R1 scaled value (x) at which the change in R2* divided by R2*at baseline scaled (y) equals 0.5. Results The apparent P50 values were significantly lower in fetal liver than in maternal liver for both gestation stages (day 14.5: 21% ± 5 [P = .04] and day 17.5: 41% ± 7 [P hemoglobin dissociation curves with a shorter protocol that excluded the hypoxic periods was demonstrated. Conclusion MR imaging

  15. Effect of high hydrostatic pressure on small oxygen-related clusters in silicon: LVM studies

    International Nuclear Information System (INIS)

    Murin, L.I.; Lindstroem, J.L.; Misiuk, A.

    2003-01-01

    Local vibrational mode (LVM) spectroscopy is used to explore the effect of high hydrostatic pressure (HP) on the formation of small oxygen-related clusters (dimers, trimers, thermal donors, and C-O complexes) at 450 deg. C and 650 deg. C in Cz-Si crystals with different impurity content and prehistory. It is found, in agreement with previous studies, that HP enhances the oxygen clustering in Cz-Si at elevated temperatures. The effect of HP is related mainly to enhancement in the diffusivity of single oxygen atoms and small oxygen aggregates. HP does not noticeably increase the binding energies of the most simple oxygen related complexes like O 2i , C s O ni . The biggest HP effect on the thermal double donor (TDDs) generation is revealed in hydrogenated samples. Heat-treatment of such samples at 450 deg. C under HP results in extremely high TDD introduction rates as well as in a strong increase in the concentration of the first TDD species

  16. High Precision Continuous and Real-Time Measurement of Atmospheric Oxygen Using Cavity Ring-Down Spectroscopy.

    Science.gov (United States)

    Kim-Hak, D.; Hoffnagle, J.; Rella, C.; Sun, M.

    2016-12-01

    Oxygen is a major and vital component of the Earth atmosphere representing about 21% of its composition. It is consumed or produced through biochemical processes such as combustion, respiration, and photosynthesis. Although atmospheric oxygen is not a greenhouse gas, it can be used as a top-down constraint on the carbon cycle. The variation observations of oxygen in the atmosphere are very small, in the order of the few ppm's. This presents the main technical challenge for measurement as a very high level of precision is required and only few methods including mass spectrometry, fuel cell, and paramagnetic are capable of overcoming it. Here we present new developments of a high-precision gas analyzer that utilizes the technique of Cavity Ring-Down Spectroscopy to measure oxygen concentration and oxygen isotope. Its compact and ruggedness design combined with high precision and long-term stability allows the user to deploy the instrument in the field for continuous monitoring of atmospheric oxygen level. Measurements have a 1-σ 5-minute averaging precision of 1-2 ppm for O2 over a dynamic range of 0-20%. We will present supplemental data acquired from our 10m tower measurements in Santa Clara, CA.

  17. Modifiers of hemoglobin/oxygen affinity as sensitizers of tumors to radiation

    International Nuclear Information System (INIS)

    Hirst, D.G.; Wood, P.J.

    1987-01-01

    A powerful mechanism in the control of oxygen delivery to tissues is the allosteric modification of hemoglobin. Increased or decreased release of oxygen can be achieved by altering the affinity of hemoglobin for oxygen. Several studies have shown that tumor radiosensitivity is dependent on this relationship. The authors studied affinity changes produced in two distinctly different ways. Tumor bearing mice were given isovolemic exchange blood transfusions with the blood from donor mice which had been exposed to abnormal oxygen tensions, leading to increased or slightly decreased levels of 2,3-diphosphoglycerate (2,3 DPG) in their blood. When the recipient mice were irradiated, those receiving the blood with higher 2,3 DPG levels showed greater tumor sensitivity to radiation. An alternative strategy is the use of drugs which directly alter hemoglobin/oxygen affinity. The authors studied three antihyperlipoproteinemia drugs, all of which have produced markedly reduced affinities in vivo. Preliminary data indicate that the radiosensitization produced by at least one of these compounds is less than would have been expected from the 2,3 DPG experiments

  18. Unraveling the structure and chemical mechanisms of highly oxygenated intermediates in oxidation of organic compounds

    KAUST Repository

    Wang, Zhandong

    2017-11-28

    Decades of research on the autooxidation of organic compounds have provided fundamental and practical insights into these processes; however, the structure of many key autooxidation intermediates and the reactions leading to their formation still remain unclear. This work provides additional experimental evidence that highly oxygenated intermediates with one or more hydroperoxy groups are prevalent in the autooxidation of various oxygenated (e.g., alcohol, aldehyde, keto compounds, ether, and ester) and nonoxygenated (e.g., normal alkane, branched alkane, and cycloalkane) organic compounds. These findings improve our understanding of autooxidation reaction mechanisms that are routinely used to predict fuel ignition and oxidative stability of liquid hydrocarbons, while also providing insights relevant to the formation mechanisms of tropospheric aerosol building blocks. The direct observation of highly oxygenated intermediates for the autooxidation of alkanes at 500–600 K builds upon prior observations made in atmospheric conditions for the autooxidation of terpenes and other unsaturated hydrocarbons; it shows that highly oxygenated intermediates are stable at conditions above room temperature. These results further reveal that highly oxygenated intermediates are not only accessible by chemical activation but also by thermal activation. Theoretical calculations on H-atom migration reactions are presented to rationalize the relationship between the organic compound’s molecular structure (n-alkane, branched alkane, and cycloalkane) and its propensity to produce highly oxygenated intermediates via extensive autooxidation of hydroperoxyalkylperoxy radicals. Finally, detailed chemical kinetic simulations demonstrate the influence of these additional reaction pathways on the ignition of practical fuels.

  19. Unraveling the structure and chemical mechanisms of highly oxygenated intermediates in oxidation of organic compounds

    KAUST Repository

    Wang, Zhandong; Popolan-Vaida, Denisia M.; Chen, Bingjie; Moshammer, Kai; Mohamed, Samah; Wang, Heng; Sioud, Salim; Raji, Misjudeen; Kohse-Hö inghaus, Katharina; Hansen, Nils; Dagaut, Philippe; Leone, Stephen R.; Sarathy, Mani

    2017-01-01

    Decades of research on the autooxidation of organic compounds have provided fundamental and practical insights into these processes; however, the structure of many key autooxidation intermediates and the reactions leading to their formation still remain unclear. This work provides additional experimental evidence that highly oxygenated intermediates with one or more hydroperoxy groups are prevalent in the autooxidation of various oxygenated (e.g., alcohol, aldehyde, keto compounds, ether, and ester) and nonoxygenated (e.g., normal alkane, branched alkane, and cycloalkane) organic compounds. These findings improve our understanding of autooxidation reaction mechanisms that are routinely used to predict fuel ignition and oxidative stability of liquid hydrocarbons, while also providing insights relevant to the formation mechanisms of tropospheric aerosol building blocks. The direct observation of highly oxygenated intermediates for the autooxidation of alkanes at 500–600 K builds upon prior observations made in atmospheric conditions for the autooxidation of terpenes and other unsaturated hydrocarbons; it shows that highly oxygenated intermediates are stable at conditions above room temperature. These results further reveal that highly oxygenated intermediates are not only accessible by chemical activation but also by thermal activation. Theoretical calculations on H-atom migration reactions are presented to rationalize the relationship between the organic compound’s molecular structure (n-alkane, branched alkane, and cycloalkane) and its propensity to produce highly oxygenated intermediates via extensive autooxidation of hydroperoxyalkylperoxy radicals. Finally, detailed chemical kinetic simulations demonstrate the influence of these additional reaction pathways on the ignition of practical fuels.

  20. Oxygen, a Key Factor Regulating Cell Behavior during Neurogenesis and Cerebral Diseases.

    Science.gov (United States)

    Zhang, Kuan; Zhu, Lingling; Fan, Ming

    2011-01-01

    Oxygen is vital to maintain the normal functions of almost all the organs, especially for brain which is one of the heaviest oxygen consumers in the body. The important roles of oxygen on the brain are not only reflected in the development, but also showed in the pathological processes of many cerebral diseases. In the current review, we summarized the oxygen levels in brain tissues tested by real-time measurements during the embryonic and adult neurogenesis, the cerebral diseases, or in the hyperbaric/hypobaric oxygen environment. Oxygen concentration is low in fetal brain (0.076-7.6 mmHg) and in adult brain (11.4-53.2 mmHg), decreased during stroke, and increased in hyperbaric oxygen environment. In addition, we reviewed the effects of oxygen tensions on the behaviors of neural stem cells (NSCs) in vitro cultures at different oxygen concentration (15.2-152 mmHg) and in vivo niche during different pathological states and in hyperbaric/hypobaric oxygen environment. Moderate hypoxia (22.8-76 mmHg) can promote the proliferation of NSCs and enhance the differentiation of NSCs into the TH-positive neurons. Next, we briefly presented the oxygen-sensitive molecular mechanisms regulating NSCs proliferation and differentiation recently found including the Notch, Bone morphogenetic protein and Wnt pathways. Finally, the future perspectives about the roles of oxygen on brain and NSCs were given.

  1. Oxygen, a key factor regulating cell behaviour during neurogenesis and cerebral diseases

    Directory of Open Access Journals (Sweden)

    Kuan eZhang

    2011-04-01

    Full Text Available Oxygen is vital to maintain the normal functions of alomost all the organs, especially for brain which is one of the heaviest oxygen consumers in the body. The important roles of oxygen on the brain are not only reflected in the development, but also showed in the pathological processes of many cerebral diseases. In the current review, we summarized the oxygen levels in brain tissues tested by real-time measurements during the embryonic and adult neurogenesis, the cerebral diseases or in the hyperbaric/hypobaric oxygen environment. Oxygen concentration is low in fetal brain (0.01%- 1% and in adult brain (1.5%-7%, decreased during stroke, and increased in hyperbaric oxygen environment. In addition, we reviewed the effects of oxygen tensions on the behaviors of neural stem cells (NSCs in vitro cultures at different oxygen concentration (2%-20% and in vivo niche during different pathological states and in hyperbaric/hypobaric oxygen environment. Moderate hypoxia (3%-10% is known can promote the proliferation of NSCs and enhance the differentiation of NSCs into the TH-positive neurons. Next, we briefly presented the oxygen-sensitive molecular mechanisms regulating NSCs proliferation and differentiation recently found including the Notch, BMP and Wnt pathways. Finally, the future perspectives about the roles of oxygen on brain and NSCs were given.

  2. Traumatic tension pneumocephalus: Two case reports

    Directory of Open Access Journals (Sweden)

    Abubaker Al-Aieb

    2017-01-01

    Conclusions: These are two rare cases with posttraumatic tension pneumocephalus treated conservatively with a favorable outcome. Early diagnosis of tension pneumocephalus is a crucial step to facilitate early recovery; however, the associated injuries need attention as they could influence the hospital course.

  3. High-spatial-resolution mapping of the oxygen concentration in cortical tissue (Conference Presentation)

    Science.gov (United States)

    Jaswal, Rajeshwer S.; Yaseen, Mohammad A.; Fu, Buyin; Boas, David A.; Sakadžic, Sava

    2016-03-01

    Due to a lack of imaging tools for high-resolution imaging of cortical tissue oxygenation, the detailed maps of the oxygen partial pressure (PO2) around arterioles, venules, and capillaries remain largely unknown. Therefore, we have limited knowledge about the mechanisms that secure sufficient oxygen delivery in microvascular domains during brain activation, and provide some metabolic reserve capacity in diseases that affect either microvascular networks or the regulation of cerebral blood flow (CBF). To address this challenge, we applied a Two-Photon PO2 Microscopy to map PO2 at different depths in mice cortices. Measurements were performed through the cranial window in the anesthetized healthy mice as well as in the mouse models of microvascular dysfunctions. In addition, microvascular morphology was recorded by the two-photon microscopy at the end of each experiment and subsequently segmented. Co-registration of the PO2 measurements and exact microvascular morphology enabled quantification of the tissue PO2 dependence on distance from the arterioles, capillaries, and venules at various depths. Our measurements reveal significant spatial heterogeneity of the cortical tissue PO2 distribution that is dominated by the high oxygenation in periarteriolar spaces. In cases of impaired oxygen delivery due to microvascular dysfunction, significant reduction in tissue oxygenation away from the arterioles was observed. These tissue domains may be the initial sites of cortical injury that can further exacerbate the progression of the disease.

  4. Theoretical analysis of the dose dependence of the oxygen enhancement ratio and its relevance for clinical applications

    International Nuclear Information System (INIS)

    Wenzl, Tatiana; Wilkens, Jan J

    2011-01-01

    The increased resistance of hypoxic cells to ionizing radiation is usually believed to be the primary reason for treatment failure in tumors with oxygen-deficient areas. This oxygen effect can be expressed quantitatively by the oxygen enhancement ratio (OER). Here we investigate theoretically the dependence of the OER on the applied local dose for different types of ionizing irradiation and discuss its importance for clinical applications in radiotherapy for two scenarios: small dose variations during hypoxia-based dose painting and larger dose changes introduced by altered fractionation schemes. Using the widespread Alper-Howard-Flanders and standard linear-quadratic (LQ) models, OER calculations are performed for T1 human kidney and V79 Chinese hamster cells for various dose levels and various hypoxic oxygen partial pressures (pO2) between 0.01 and 20 mmHg as present in clinical situations in vivo. Our work comprises the analysis for both low linear energy transfer (LET) treatment with photons or protons and high-LET treatment with heavy ions. A detailed analysis of experimental data from the literature with respect to the dose dependence of the oxygen effect is performed, revealing controversial opinions whether the OER increases, decreases or stays constant with dose. The behavior of the OER with dose per fraction depends primarily on the ratios of the LQ parameters alpha and beta under hypoxic and aerobic conditions, which themselves depend on LET, pO2 and the cell or tissue type. According to our calculations, the OER variations with dose in vivo for low-LET treatments are moderate, with changes in the OER up to 11% for dose painting (1 or 3 Gy per fraction compared to 2 Gy) and up to 22% in hyper-/hypofractionation (0.5 or 20 Gy per fraction compared to 2 Gy) for oxygen tensions between 0.2 and 20 mmHg typically measured clinically in hypoxic tumors. For extremely hypoxic cells (0.01 mmHg), the dose dependence of the OER becomes more pronounced (up to 36

  5. Oxygen-tension measurements - The first step towards prevention and early detection of anastomotic leakage

    NARCIS (Netherlands)

    Tanase, D.; French, P.J.; Komen, N.; Kleinrensink, G.J.; Jeekel, J.; Lange, J.F.; Draaijer, A.

    2007-01-01

    Many patients still die every year as a result of anastomotic leakage after surgery. The medical world needs an objective aid to detect leakage during surgery and during the critical recovery period. We propose a miniature measurement system to detect adequate tissue oxygenation pre- and

  6. Exploratory experimental investigations on post-tensioned structural glass beams

    DEFF Research Database (Denmark)

    Louter, C.; Nielsen, Jens Henrik; Belis, J.

    2013-01-01

    This paper discusses two projects on post-tensioned glass beams, performed at EPFL and DTU, respectively. In these projects small scale glass beams (length of 1.5m and 1m) are post-tensioned by means of steel threaded rods tensioned at the beam ends. The purpose of post-tensioning glass beams...

  7. Tumor Oxygen Dynamics: Correlation of In Vivo MRI with Histological Findings

    Directory of Open Access Journals (Sweden)

    Dawen Zhao

    2003-07-01

    Full Text Available Tumor oxygenation has long been recognized as a significant factor influencing cancer therapy. We recently established a novel magnetic resonance in vivo approach to measuring regional tumor oxygen tension, FREDOM (Fluorocarbon Relaxometry Using Echo Planar Imaging for Dynamic Oxygen Mapping, using hexafluorobenzene (HFB as the reporter molecule. We have now investigated oxygen dynamics in the two Dunning prostate R3327 rat tumor sublines, AT1 and H. FREDOM revealed considerable intratumoral heterogeneity in the distribution of pO2 values in both sublines. The anaplastic fastergrowing AT1 tumors were more hypoxic compared with the size-matched, well-differentiated, and slower-growing H tumors. Respiratory challenge with oxygen produced significant increases in mean and median pO2 in all the H tumors (P3 cm3. Immunohistochemical studies using the hypoxia marker, pimonidazole, and the vascular endothelial cell marker, CD31, confirmed that the H tumors had more extensive vasculature and less hypoxia than the AT1 tumors. These results further validate the utilization of FREDOM to monitor tumor oxygenation and concur with the hypothesis that the level of hypoxia is related to tumor growth rate and poor vascularity.

  8. Indentation of a floating elastic sheet: geometry versus applied tension.

    Science.gov (United States)

    Box, Finn; Vella, Dominic; Style, Robert W; Neufeld, Jerome A

    2017-10-01

    The localized loading of an elastic sheet floating on a liquid bath occurs at scales from a frog sitting on a lily pad to a volcano supported by the Earth's tectonic plates. The load is supported by a combination of the stresses within the sheet (which may include applied tensions from, for example, surface tension) and the hydrostatic pressure in the liquid. At the same time, the sheet deforms, and may wrinkle, because of the load. We study this problem in terms of the (relatively weak) applied tension and the indentation depth. For small indentation depths, we find that the force-indentation curve is linear with a stiffness that we characterize in terms of the applied tension and bending stiffness of the sheet. At larger indentations, the force-indentation curve becomes nonlinear and the sheet is subject to a wrinkling instability. We study this wrinkling instability close to the buckling threshold and calculate both the number of wrinkles at onset and the indentation depth at onset, comparing our theoretical results with experiments. Finally, we contrast our results with those previously reported for very thin, highly bendable membranes.

  9. High intensity aerobic interval training improves peak oxygen consumption in patients with metabolic syndrome: CAT

    Directory of Open Access Journals (Sweden)

    Alexis Espinoza Salinas

    2014-06-01

    Full Text Available Introduction A number of cardiovascular risk factors characterizes the metabolic syndrome: insulin resistance (IR, low HDL cholesterol and high triglycerides. The aforementioned risk factors lead to elevated levels of abdominal adipose tissue, resulting in oxygen consumption deficiency. Purpose To verify the validity and applicability of using high intensity interval training (HIIT in subjects with metabolic syndrome and to answer the following question: Can HIIT improve peak oxygen consumption? Method The systematic review "Effects of aerobic interval training on exercise capacity and metabolic risk factors in individuals with cardiometabolic disorders" was analyzed. Results Data suggests high intensity aerobic interval training increases peak oxygen consumption by a standardized mean difference of 3.60 mL/kg-1/min-1 (95% confidence interval, 0.28-4.91. Conclusion In spite of the methodological shortcomings of the primary studies included in the systematic review, we reasonably conclude that implementation of high intensity aerobic interval training in subjects with metabolic syndrome, leads to increases in peak oxygen consumption.

  10. Determination of oxygen content in high Tc superconductors by deuteron particle activation analysis

    International Nuclear Information System (INIS)

    Tao Zhenlan; Yao, Y.D.; Kao, Y.H.

    1993-01-01

    The experimental method for determining the oxygen content in high T c superconductors is described in detail. This method is applied to determination of oxygen content in high T c Y-Ba-Cu-O and Bi-Sr-Ca-Cu-O samples in which the stoichiometry is varied by reducing the copper and bismuth concentrations. The oxygen concentration is found to vary linearly with Cu(x = 0-0.2) and Bi (x = 0-0.4) deficiencies in YBa 2 Cu 3(1-x )O y and Bi 2(1-x) Sr 2 CaCu 2 O y respectively. X-ray powder diffraction measurements show that the compound of YBa 2 Cu 3(1-x) O y is orthorhombic in the variation range of x = 0-0.2

  11. Thermal Analysis of Bending Under Tension Test

    DEFF Research Database (Denmark)

    Ceron, Ermanno; Martins, Paulo A.F.; Bay, Niels

    2014-01-01

    during testing is similar to the one in the production tool. A universal sheet tribo-tester has been developed, which can run multiple tests automatically from coil. This allows emulating the temperature increase as in production. The present work performs finite element analysis of the evolution......The tribological conditions in deep drawing can be simulated in the Bending Under Tension test to evaluate the performance of new lubricants, tool materials, etc. Deep drawing production with automatic handling runs normally at high rate. This implies considerable heating of the tools, which...... sometimes can cause lubricant film breakdown and galling. In order to replicate the production conditions in bending under tension testing it is thus important to control the tool/workpiece interface temperature. This can be done by pre-heating the tool, but it is essential that the interface temperature...

  12. Rapid cable tension estimation using dynamic and mechanical properties

    Science.gov (United States)

    Martínez-Castro, Rosana E.; Jang, Shinae; Christenson, Richard E.

    2016-04-01

    Main tension elements are critical to the overall stability of cable-supported bridges. A dependable and rapid determination of cable tension is desired to assess the state of a cable-supported bridge and evaluate its operability. A portable smart sensor setup is presented to reduce post-processing time and deployment complexity while reliably determining cable tension using dynamic characteristics extracted from spectral analysis. A self-recording accelerometer is coupled with a single-board microcomputer that communicates wirelessly with a remote host computer. The portable smart sensing device is designed such that additional algorithms, sensors and controlling devices for various monitoring applications can be installed and operated for additional structural assessment. The tension-estimating algorithms are based on taut string theory and expand to consider bending stiffness. The successful combination of cable properties allows the use of a cable's dynamic behavior to determine tension force. The tension-estimating algorithms are experimentally validated on a through-arch steel bridge subject to ambient vibration induced by passing traffic. The tension estimation is determined in well agreement with previously determined tension values for the structure.

  13. High temperature expansions for the free energy of vortices respectively the string tension in lattice gauge theories

    International Nuclear Information System (INIS)

    Muenster, G.

    1980-05-01

    We derive high temperature cluster expansions for the free energy of vortices in SU(2) and Z 2 lattice gauge theories in 3 and 4 dimensions. The expected behaviour of the vortex free energy is verified. It obeys an area law behaviour. The coefficient of the area is shown to be equal to the string tension between static quarks. We calculate its expansion up to 12th order. For SU(2) in 4 dimensions the result is compared with Monte Carlo calculations of Creutz and is in good agreement at strong and intermediate coupling. (orig.)

  14. Frontal lobe oxygenation is maintained during hypotension following propofol-fentanyl anesthesia

    DEFF Research Database (Denmark)

    Nissen, P.; Lieshout, J.J. van; Nielsen, H.B.

    2009-01-01

    Near-infrared spectroscopy (NIRS) assesses cerebral oxygen saturation (Sco2) as a balance between cerebral oxygen delivery and consumption. In 71 patients, we evaluated whether marked reduction in mean arterial pressure (MAP) during propofol-fentanyl anesthesia induction affects frontal lobe Sco2....... The NIRS-determined arm muscle oxygenation (Smo2), heart rate (HR), and cardiac output (CO) were monitored, endtidal carbon dioxide tension was controlled at 3.5 to 4.5 kPa, and central blood volume was maintained. Before anesthesia, the median (range) MAP, HR, and CO were 93 mm Hg (61-126 mm Hg), 76 beats......, the median (range) NIRS-determined Smo2 also decreased (73% [54%-94%] to 71% [52%-87%]), whereas Sco2 increased from 67% (46%-93%) to 74% (48%-95%) (P anesthesia induction, variables recovered and remained at preanesthetic levels during surgery. The findings...

  15. The Equilibrium Spreading Tension of Pulmonary Surfactant

    OpenAIRE

    Dagan, Maayan P.; Hall, Stephen B.

    2015-01-01

    Monomolecular films at an air/water interface coexist at the equilibrium spreading tension (γe) with the bulk phase from which they form. For individual phospholipids, γe is single-valued, and separates conditions at which hydrated vesicles adsorb from tensions at which overcompressed monolayers collapse. With pulmonary surfactant, isotherms show that monolayers compressed on the surface of bubbles coexist with the three-dimensional collapsed phase over a range of surface tensions. γe therefo...

  16. Tension perturbations of black brane spacetimes

    International Nuclear Information System (INIS)

    Traschen, Jennie; Fox, Daniel

    2004-01-01

    We consider black brane spacetimes that have at least one spatial translation Killing field that is tangent to the brane. A new parameter, the tension of a spacetime, is defined. The tension parameter is associated with spatial translations in much the same way that the ADM mass is associated with the time translation Killing field. In this work, we explore the implications of the spatial translation symmetry for small perturbations around a background black brane. For static-charged black branes we derive a law which relates the tension perturbation to the surface gravity times the change in the horizon area, plus terms that involve variations in the charges and currents. We find that as a black brane evaporates the tension decreases. We also give a simple derivation of a first law for black brane spacetimes. These constructions hold when the background stress-energy is governed by a Hamiltonian, and the results include arbitrary perturbative stress-energy sources

  17. Phases of fracture process zone and tension softening properties of concrete

    International Nuclear Information System (INIS)

    Mihashi, H.; Nomura, N.

    1991-01-01

    The safety and serviceability of concrete structures are influenced very much by the cracking behavior of concrete. Since comprehensive numerical analysis techniques have been extensively developed to predict the mechanical behavior of concrete structures in the limit state, it is essential to study the constitutive laws to describe the cracking behavior of concrete in detail. The tension softening behavior of concrete is highly dominated by the existence of a fracture process zone (FPZ) ahead of a crack tip. Since the direct observation of the FPZ of concrete is hardly possible, the indirect techniques are applied, but it is still ambiguous what happens in the FPZ and how it affects the tension softening property. The purpose of this study is to present the property of the FPZ focusing on the influence of material structures by means of three-dimensional acoustic emission. These results are correlated to tension softening behavior evaluated by a numerical analysis to discuss how the tension softening property is related to the characteristics of the FPZ. The test procedure and the results are reported. (K.I.)

  18. A Universal Method to Engineer Metal Oxide-Metal-Carbon Interface for Highly Efficient Oxygen Reduction.

    Science.gov (United States)

    Lv, Lin; Zha, Dace; Ruan, Yunjun; Li, Zhishan; Ao, Xiang; Zheng, Jie; Jiang, Jianjun; Chen, Hao Ming; Chiang, Wei-Hung; Chen, Jun; Wang, Chundong

    2018-03-27

    Oxygen is the most abundant element in the Earth's crust. The oxygen reduction reaction (ORR) is also the most important reaction in life processes and energy converting/storage systems. Developing techniques toward high-efficiency ORR remains highly desired and a challenge. Here, we report a N-doped carbon (NC) encapsulated CeO 2 /Co interfacial hollow structure (CeO 2 -Co-NC) via a generalized strategy for largely increased oxygen species adsorption and improved ORR activities. First, the metallic Co nanoparticles not only provide high conductivity but also serve as electron donors to largely create oxygen vacancies in CeO 2 . Second, the outer carbon layer can effectively protect cobalt from oxidation and dissociation in alkaline media and as well imparts its higher ORR activity. In the meanwhile, the electronic interactions between CeO 2 and Co in the CeO 2 /Co interface are unveiled theoretically by density functional theory calculations to justify the increased oxygen absorption for ORR activity improvement. The reported CeO 2 -Co-NC hollow nanospheres not only exhibit decent ORR performance with a high onset potential (922 mV vs RHE), half-wave potential (797 mV vs RHE), and small Tafel slope (60 mV dec -1 ) comparable to those of the state-of-the-art Pt/C catalysts but also possess long-term stability with a negative shift of only 7 mV of the half-wave potential after 2000 cycles and strong tolerance against methanol. This work represents a solid step toward high-efficient oxygen reduction.

  19. Highly sensitive fiber-optic oxygen sensor based on palladium tetrakis (4-carboxyphenyl)porphyrin doped in ormosil

    International Nuclear Information System (INIS)

    Chu, Cheng-Shane; Chuang, Chih-Yung

    2014-01-01

    A simple, low-cost technique for fabrication of highly sensitive fiber-optic oxygen sensor is described. An organically modified silicate (ORMOSIL) as a matrix for the fabrication of oxygen sensing film was produced. The technique is based on coating the end of a plastic optical fiber with ormosil composite xerogel film sequestered with luminophore palladium (II) meso-tetra(4-carboxyphenyl)porphyrin (PdTCPP) prepared by a sol–gel process. The composite xerogel studied is tetraethylorthosilane (TEOS)/n-octyltriethoxysilane (Octyl-triEOS). Result shows that, expect for PdTCPP-doped TEOS/Octyl-triEOS composite xerogel show the high sensitivity and linear Stern–Volmer relationship which indicate the homogenous environment of the luminophore. The sensitivity of the optical oxygen sensor is quantified in terms of the ratio I N2 /I O2 , where I N2 and I O2 represent the detected fluorescence intensities in pure nitrogen and pure oxygen environments, respectively. The experimental result reveals that the PdTCPP-doped TEOS/Octyl-triEOS oxygen sensor has sensitivity of 153. - Highlights: • A simple, low-cost technique for fabrication of highly sensitive fiber-optic oxygen sensor is described. • ORMOSIL was produced to serve as a matrix for the fabrication of oxygen sensing film. • The fiber-optic oxygen sensor has sensitivity of I N2 /I 100O2 =153. • The stable and reproducible signals were obtained with the fiber-optic oxygen sensor

  20. Hyperbaric oxygen therapy ameliorates acute brain injury after porcine intracerebral hemorrhage at high altitude.

    Science.gov (United States)

    Zhu, Hai-tao; Bian, Chen; Yuan, Ji-chao; Liao, Xiao-jun; Liu, Wei; Zhu, Gang; Feng, Hua; Lin, Jiang-kai

    2015-06-15

    Intracerebral hemorrhage (ICH) at high altitude is not well understood to date. This study investigates the effects of high altitude on ICH, and examines the acute neuroprotection of hyperbaric oxygen (HBO) therapy against high-altitude ICH. Minipigs were placed in a hypobaric chamber for 72 h before the operation. ICH was induced by an infusion of autologous arterial blood (3 ml) into the right basal ganglia. Animals in the high-altitude ICH group received HBO therapy (2.5 ATA for 60 min) 30 min after ICH. Blood gas, blood glucose and brain tissue oxygen partial pressure (PbtO2) were monitored continuously for animals from all groups, as were microdialysis products including glucose, lactate, pyruvate and glutamate in perihematomal tissue from 3 to 12 h post-ICH. High-altitude ICH animals showed significantly lower PbtO2, higher lactate/pyruvate ratio (LPR) and glutamate levels than low-altitude ICH animals. More severe neurological deficits, brain edema and neuronal damage were also observed in high-altitude ICH. After HBO therapy, PbtO2 was significantly increased and LPR and glutamate levels were significantly decreased. Brain edema, neurological deficits and neuronal damage were also ameliorated. The data suggested a more serious disturbance of tissue oxygenation and cerebral metabolism in the acute stage after ICH at high altitude. Early HBO treatment reduced acute brain injury, perhaps through a mechanism involving the amelioration of the derangement of cerebral oxygenation and metabolism following high-altitude ICH.

  1. Measurement for Surface Tension of Aqueous Inorganic Salt

    Directory of Open Access Journals (Sweden)

    Jiming Wen

    2018-03-01

    Full Text Available Bubble columns are effective means of filtration in filtered containment venting systems. Here, the surface tension has a significant influence on bubble size distribution and bubble deformation, which have a strong impact on the behavior of the bubble column. The influence of aqueous inorganic compounds on the surface tension depends on the electrolytic activity, Debye length, entropy of ion hydration, and surface deficiencies or excess. In this work, the surface tensions of same specific aqueous solutions have been measured by different methods including platinum plate method, platinum ring method, and maximum bubble pressure method. The measured surface tensions of both sodium hydroxide and sodium thiosulfate are less than that of water. As solution temperature ranges from 20 to 75°C, the surface tension of 0.5 mol/L sodium hydroxide solution decreases from 71 to 55 mN/m while that of 1 mol/L solution decreases from 60 to 45 mN/m. Similarly during the same temperature range, the surface tension of 0.5 mol/L sodium thiosulfate decreases from 70 to 38 mN/m, and that of 1 mol/L sodium thiosulfate is between 68 and 36 mN/m. The analysis for the influence mechanism of aqueous inorganic on surface tension is provided. In addition, experimental results show that the surface tension of solid aerosol suspension liquid has no obvious difference from that of distilled water.

  2. Small-Bolt Torque-Tension Tester

    Science.gov (United States)

    Posey, Alan J.

    2009-01-01

    The device described here measures the torque-tension relationship for fasteners as small as #0. The small-bolt tester consists of a plate of high-strength steel into which three miniature load cells are recessed. The depth of the recess is sized so that the three load cells can be shimmed, the optimum height depending upon the test hardware. The three miniature load cells are arranged in an equilateral triangular configuration with the test bolt aligned with the centroid of the three. This is a kinematic arrangement.

  3. A highly precise frequency-based method for estimating the tension of an inclined cable with unknown boundary conditions

    Science.gov (United States)

    Ma, Lin

    2017-11-01

    This paper develops a method for precisely determining the tension of an inclined cable with unknown boundary conditions. First, the nonlinear motion equation of an inclined cable is derived, and a numerical model of the motion of the cable is proposed using the finite difference method. The proposed numerical model includes the sag-extensibility, flexural stiffness, inclination angle and rotational stiffness at two ends of the cable. Second, the influence of the dynamic parameters of the cable on its frequencies is discussed in detail, and a method for precisely determining the tension of an inclined cable is proposed based on the derivatives of the eigenvalues of the matrices. Finally, a multiparameter identification method is developed that can simultaneously identify multiple parameters, including the rotational stiffness at two ends. This scheme is applicable to inclined cables with varying sag, varying flexural stiffness and unknown boundary conditions. Numerical examples indicate that the method provides good precision. Because the parameters of cables other than tension (e.g., the flexural stiffness and rotational stiffness at the ends) are not accurately known in practical engineering, the multiparameter identification method could further improve the accuracy of cable tension measurements.

  4. Tending the tensions in co-creation

    DEFF Research Database (Denmark)

    Phillips, Professor MSO Louise; Nordentoft, Helle Merete; Pedersen, Lektor Christina Hee

    -for-granted positive value. In the panel we de-romanticise “co-creation” and explore how it is enacted in particular organisational contexts, concentrating on context-specific tensions arising in the meeting between different knowledge forms and interests. These include tensions BETWEEN dialogic views of knowledge co-creation...

  5. Surface tension in soap films: revisiting a classic demonstration

    International Nuclear Information System (INIS)

    Behroozi, F

    2010-01-01

    We revisit a classic demonstration for surface tension in soap films and introduce a more striking variation of it. The demonstration shows how the film, pulling uniformly and normally on a loose string, transforms it into a circular arc under tension. The relationship between the surface tension and the string tension is analysed and presented in a useful graphical form. (letters and comments)

  6. Surface tension in soap films: revisiting a classic demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Behroozi, F [Department of Physics, University of Northern Iowa, Cedar Falls, IA 50614 (United States)], E-mail: behroozi@uni.edu

    2010-01-15

    We revisit a classic demonstration for surface tension in soap films and introduce a more striking variation of it. The demonstration shows how the film, pulling uniformly and normally on a loose string, transforms it into a circular arc under tension. The relationship between the surface tension and the string tension is analysed and presented in a useful graphical form. (letters and comments)

  7. Bending Under Tension Test with Direct Friction Measurement

    DEFF Research Database (Denmark)

    Andreasen, Jan Lasson; Olsson, David Dam; Chodnikiewicz, K.

    2006-01-01

    A special Bending-Under-Tension (BUT) transducer has been developed in which friction around the tool radius can be directly measured when drawing a plane sheet strip around a cylindrical tool-pin under constant back tension. The front tension, back tension and torque on the tool-pin are all...... measured directly, thus enabling accurate measurement of friction and direct determination of lubricant film breakdown for varying normal pressure, sliding speed, tool radius and tool preheat temperature. The transducer is applied in an experimental investigation focusing on limits of lubrication...

  8. Kinetics of the oxygen effect in yeast irradiated in dry and wet conditions

    International Nuclear Information System (INIS)

    Kiefer, J.; Schoepfer, F.; Luggen-Hoelscher, J.

    1981-01-01

    There are indications that the radiobiological oxygen-effect consists of more than one component: in dry bacterial spores three different classes can be separated depending on exposure- and after-treatment conditions, the dependence of the oxygen-enhancement ratio (OER) on oxygen concentration shows breaks in various systems, and it has been suggested that type O and type N damage are localized in different parts of the cells. These questions were studied in the simple eucaryote Saccharomyces cerevisiae using two approaches: the dependence of OER on oxygen tension was determined both for survivial and mutation induction. Since a forward mutation was used a haploid strain had to be employed in this case. In order to assess whether also in yeast cells more than one component may exist, the techniques originally developed for bacterial spores were adapted for dried diploid yeast cells. The results show that the dependence on oxygen concentration is the same for survival and mutation within error limits, implicating DNA as the main target and that also in our system three classes of oxygen dependent damage exist

  9. Prognosis in Acute Cerebrovascular Accidents in Relation to Respiratory Pattern and Blood—gas Tensions

    Science.gov (United States)

    Rout, M. W.; Lane, D. J.; Wollner, L.

    1971-01-01

    Respiratory pattern and arterial blood gas tensions were assessed in patients with acute cerebrovascular accidents. Hyperventilation, low Pco2, and high arterial pH were associated with a poor prognosis, whereas patients with normal respiratory pattern and blood gas tensions survived. Periodic and Cheyne-Stokes breathing carried an intermediate prognosis. PMID:5091916

  10. High-oxygen and high-carbon dioxide containing atmospheres inhibit growth of food associated moulds

    NARCIS (Netherlands)

    Hoogerwerf, S.W.; Kets, E.P.W.; Dijksterhuis, J.

    2002-01-01

    Aims: The objective of this study was to determine the relationship between the growth of three foodborne fungi and high-oxygen modified atmosphere. Methods and Results: Petri dishes were incubated in a series of connected flasks, which were placed in a climatized room and flushed continuously with

  11. Magnetic tension and gravitational collapse

    International Nuclear Information System (INIS)

    Tsagas, Christos G

    2006-01-01

    The gravitational collapse of a magnetized medium is investigated by studying qualitatively the convergence of a timelike family of non-geodesic worldlines in the presence of a magnetic field. Focusing on the field's tension, we illustrate how the winding of the magnetic forcelines due to the fluid's rotation assists the collapse, while shear-like distortions in the distribution of the field's gradients resist contraction. We also show that the relativistic coupling between magnetism and geometry, together with the tension properties of the field, lead to a magneto-curvature stress that opposes the collapse. This tension stress grows stronger with increasing curvature distortion, which means that it could potentially dominate over the gravitational pull of the matter. If this happens, a converging family of non-geodesic worldlines can be prevented from focusing without violating the standard energy conditions

  12. The value of high-flow nasal cannula oxygen therapy after extubation in patients with acute respiratory failure

    Directory of Open Access Journals (Sweden)

    Hong-Zhuan Song

    Full Text Available OBJECTIVE: To investigate the value of high-flow nasal cannula oxygen therapy after extubation in patients with acute respiratory failure. METHODS: A single-center, prospective, randomized, controlled pilot trial was conducted between January 2013 and December 2014. Sixty enrolled patients were randomized immediately after extubation into either a high-flow nasal cannula group (n=30 or an air entrainment mask group (n=30 at a fixed inspired oxygen fraction (40%. The success rate of oxygen therapy, respiratory and hemodynamic parameters and subjective discomfort (using a visual analogue scale were assessed at 24h after extubation. RESULTS: The two groups were comparable at extubation. A total of 46 patients were successfully treated including 27 patients in the high-flow nasal cannula group and 19 patients in the air entrainment mask group. Compared to the air entrainment mask group, the success rate of oxygen therapy and the partial pressure of arterial oxygen were significantly higher and the respiratory rate was lower in the high-flow nasal cannula group. In addition, less discomfort related to interface displacement and airway dryness was observed in the high-flow nasal cannula group than in the air entrainment mask group. CONCLUSIONS: At a fixed inspired oxygen fraction, the application of a high-flow nasal cannula after extubation achieves a higher success rate of oxygen therapy and less discomfort at 24h than an air entrainment mask in patients with acute respiratory failure.

  13. In vitro oxygen-dependent survival of two human cell lines after combined radiations tirapazamin and cisplatin

    International Nuclear Information System (INIS)

    Lartigau, E.; Stern, S.; Guichard, M.

    2000-01-01

    Recent data have shown that the in vitro and in vivo cytotoxicity of bioreductive drugs could be significantly cytotoxicity of bioreductive drugs could be significantly increased by combination with ionising radiation or chemotherapy. Various parameters such as oxygen tension and timing of administration of the drugs could play a crucial role in the efficacy of combined treatment modalities. The aim of this study was to define the oxygen dependency of cell survival after in vitro irradiation and incubation with tirapazamin, a bioreductive drug, and cisplatin given alone or simultaneously. Two human cell lines were studied: one cell line sensitive to tirapazamin, Na11+, a pigmented melanoma with a high percentage of hypoxic cells, and a less sensitive cell line to tirapazamin, HRT18, a rectal adenocarcinoma. Gas changes were made to study cell survival at four different oxygen concentrations (pO 2 ): air (20.9 % O 2 ), 10.2 and 0.2 %. Cells were incubated with tirapazamin and cisplatin alone or combined for one hour at 37 deg C, then irradiated and cultured. For Na11+, cell survival after irradiation was comparable in air and at 10 % oxygen with the two drugs given alone or combined. At 2 and 0.2 % oxygen, cell killing was largely increased by tirapazamin and was not modified by the addition of cisplatin. For HRT18, cell survival was not modified when cisplatin was added to radiation, whatever the oxygen partial pressure. At low pO 2 (2 and 0.2 %) the cytotoxic effect of tirapazamin was not significantly decreased by the addition of cisplatin. When cytotoxic and bioreductive drugs are combined to radiation, the magnitude of the observed effect is highly dependent on the partial oxygen pressure and on the sensitivity of the cell line to the individual drugs. This has very important implications for clinical strategies based on combined chemo-radiotherapy. (authors)

  14. [Reduced muscular oxygen tension and nerve impulse transmission from antishock hose. Reduction of oxygen tension in the tibial muscle and impulse transmission in the peroneal nerve from pneumatic -1 pressure from antishock hose].

    Science.gov (United States)

    Willy, C; Völker, H U; Weber, F; Albert, U; Sterk, J; Helm, M; Gerngross, H; Thomas, A

    1998-07-01

    The aim of the study was to assess, whether the pneumatic pressure of an antishock-trouser (AST) of 20-40 mm Hg induces a decreased oxygenation of the anterior tibial muscle and attenuates muscular response potential (MRP) of n. peronaeus profundus? Among 22 normotensive, healthy volunteers the AST were tested by applying pressure values between 0 and 100 mm Hg and measuring the intracompartmental pressure, the muscular oxygen pressure as well as the MRP by electroneurographic means within a period of 6 hours. The median initial intracompartmental pressure value of the m. tibialis anterior was 12.0 mm Hg (Q25%/Q75%: 8.9/17.3), the muscular oxygen pressure 14.8 mm Hg (Q25%/Q75%: 11.5/22.0). Transmission of the pneumatic AST-leg segment pressure to the muscle: 97.7% (Q25%/Q75%: 89.2/99.8). Already in the low AST pressure field (20-40 mm Hg) a severe hypoxia occurred in one case. A reduction of MRP was noticed at an AST pressure rate of 10 mm Hg. In 5 of 6 cases AST pressure values of 60 mm Hg led to pathological pO2-values within 5-20 minutes. Almost without exception AST-pressure rates < 60 mm Hg resulted in an anoxia of the muscle and loss of the MRP. We should demand that the AST are only applied with models where the pressure generated within the single segments can be controlled by pressure gauge. The application of the AST seems to be justified for polytraumatised in severe haemorrhagic shock where the risk of a local tissue ischemia with systemical consequences must deliberately be accepted.

  15. Investigation on the improved radiation hardness of silicon detectors with high oxygen concentration

    CERN Document Server

    Moll, Michael; Lindström, G

    2000-01-01

    We present an investigation on the influence of the oxygen concentration on radiation-induced changes in the effective doping concentration of silicon detectors. Diodes fabricated from silicon with interstitial oxygen content ranging from below 2*10/sup 14/ to 9*10/sup 17/ cm/sup -3/ have been irradiated with fast neutrons up to a fluence of 2*10/sup 15/ cm/sup -2/. Our main interest focused on the so-called stable damage component in the change of the effective doping concentration being of prime importance for the application of silicon detectors in high-energy physics experiments. We demonstrate, that with a high oxygen enrichment the donor removal is appreciably reduced, reaching a value of only 10601130f the initial doping concentration for [O/sub i/]=9*10/sup 17/ cm/sup -3/, while for normal detector grade material with [O/sub i/] below 5*10/sup 16/ cm /sup -3/ that value is 60-90Furthermore, we show that the fluence proportional introduction of stable acceptors is independent of the oxygen concentratio...

  16. High Pressure and High Temperature State of Oxygen Enriched Ice

    Science.gov (United States)

    LI, M.; Zhang, S.; Jeanloz, R.; Militzer, B.

    2016-12-01

    Interior models for Uranus and Neptune include a hydrogen/helium/water outer envelope and a core of rock and metal at the center, with superionic water-rich ice proposed as comprising an intermediate layer. Here we consider an oxygen-enriched ice, such as H2O2 hydrogen peroxide (± water), that could form through chemical reaction between water-rich and underlying rocky (i.e., oxygen-rich) layers. As oxygen and its compounds (e.g., H2O, SiO2) form metallic fluids at pressures above 100-150 GPa, the problem amounts to considering oxygen alloying of semiconducting or metallic water. The density of H2O2 is 1.45 g/cc at ambient pressure and 0° C, increasing to 1.71 g/cc in the solid state at about -20° C. There are no Hugoniot data beyond 30 GPa, so we estimated Hugoniots for H2O2 with different initial densities, using both a mixing model based on Hugoniot data for H2O2 and 1/2 O2 (molar volume summation under pressure) and ab initio calculations for unreacted H2O2. The results agree with each other to pressures of about 200 GPa, and the ab initio calculations show evidence of a superionic state at temperatures as low as 500 K, much lower than for water ice. Hydrogen peroxide is expected to be liquid along planetary isentropes for Uranus and Neptune, suggesting that H2O2 may not be present as a pure compound in these planets. Instead, oxygen-enriched H2O ice may be the relevant form of water and oxygen, and might be produced in the laboratory by way of dynamic compression of H2O2 or laser-heating of statically compressed H2O + O2 and/or H2O2.

  17. Muscle trigger point therapy in tension-type headache.

    Science.gov (United States)

    Alonso-Blanco, Cristina; de-la-Llave-Rincón, Ana Isabel; Fernández-de-las-Peñas, César

    2012-03-01

    Recent evidence suggests that active trigger points (TrPs) in neck and shoulder muscles contribute to tension-type headache. Active TrPs within the suboccipital, upper trapezius, sternocleidomastoid, temporalis, superior oblique and lateral rectus muscles have been associated with chronic and episodic tension-type headache forms. It seems that the pain profile of this headache may be provoked by referred pain from active TrPs in the posterior cervical, head and shoulder muscles. In fact, the presence of active TrPs has been related to a higher degree of sensitization in tension-type headache. Different therapeutic approaches are proposed for proper TrP management. Preliminary evidence indicates that inactivation of TrPs may be effective for the management of tension-type headache, particularly in a subgroup of patients who may respond positively to this approach. Different treatment approaches targeted to TrP inactivation are discussed in the current paper, focusing on tension-type headache. New studies are needed to further delineate the relationship between muscle TrP inactivation and tension-type headache.

  18. Patients with tension-type headaches feel stigmatized

    Directory of Open Access Journals (Sweden)

    Sanjay Prakash

    2016-01-01

    Full Text Available The author, a sufferer of tension-type headache (TTH, believes that the word "tension" in "tension-type headache" carries a social stigma and that patients do not accept a diagnosis of TTH readily. TTH is the most common primary headache disorder. The disability of TTH as a burden of society is greater than that of migraine. Absenteeism because of TTH is higher than that due to migraine. However, patients with TTH do not go for consultation. Even the prevalence of new daily persistent headache (NDPH is 12 times higher at the headache clinic than that of chronic TTH (CTTH. These points hint that TTH patients probably do not want to visit the clinic. The author believes that it could be because of the stigma attached to "tension." Herein, the author has noted the first responses given by 50 consecutive patients with TTH when they were told that they had been suffering from TTH. The first answer of 64% of patients with TTH was "I do not have any tension/stress ." This denial is similar to the denial declared by patients with depression. Depression and tension are similar in the sense that both are considered as a signs of personal weakness. Such a preconception in the society creates a stigma, and patients deny the diagnosis, conceal symptoms, and become reluctant to seek help and treatment.

  19. Needle Decompression of Tension Pneumothorax with Colorimetric Capnography.

    Science.gov (United States)

    Naik, Nimesh D; Hernandez, Matthew C; Anderson, Jeff R; Ross, Erika K; Zielinski, Martin D; Aho, Johnathon M

    2017-11-01

    The success of needle decompression for tension pneumothorax is variable, and there are no objective measures assessing effective decompression. Colorimetric capnography, which detects carbon dioxide present within the pleural space, may serve as a simple test to assess effective needle decompression. Three swine underwent traumatically induced tension pneumothorax (standard of care, n = 15; standard of care with needle capnography, n = 15). Needle thoracostomy was performed with an 8-cm angiocatheter. Similarly, decompression was performed with the addition of colorimetric capnography. Subjective operator assessment of decompression was recorded and compared with true decompression, using thoracoscopic visualization for both techniques. Areas under receiver operating curves were calculated and pairwise comparison was performed to assess statistical significance (P pneumothorax, that is, the absence of any pathologic/space-occupying lesion, in 100% of cases (10 of 10 attempts). Standard of care needle decompression was detected by operators in 9 of 15 attempts (60%) and was detected in 3 of 10 attempts when tension pneumothorax was not present (30%). True decompression, under direct visualization with thoracoscopy, occurred 15 of 15 times (100%) with capnography, and 12 of 15 times (80%) without capnography. Areas under receiver operating curves were 0.65 for standard of care and 1.0 for needle capnography (P = .002). Needle decompression with colorimetric capnography provides a rapid, effective, and highly accurate method for eliminating operator bias for tension pneumothorax decompression. This may be useful for the treatment of this life-threatening condition. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  20. [Current issues, problems and prospects of tension-free hernioplasty (review)].

    Science.gov (United States)

    2014-01-01

    In the present study there are discussed modern methods of the tension free hernioplastics, the complications associated with them and technical difficulties, up-to-date views and the perspectives of the issue development in terms of avoiding infectious complications, positioning of implants and their fixation. Hernia is one of the widespread surgical pathologies as it is found in 4% of the population and its share among the inpatient surgical diseases is about 18-30%. Consequently annually up to 20-21 mln hernioplasties are carried out worldwide. Despite of many years of experience in the field of hernia surgical treatment there still exist many unsolved problems such as safe closure of defects of abdominal cavity wall. Up to 200 methods of hernioplastics, various implantations and application of synthetic materials refer to lack of the optimal surgical strategy. In modern herniology priorities are given to tension free plastics. The merge of the synthetic implants and "tension free hernioplastics" concepts enabled sharp reduction of the side effects list, making it possible to perform successful surgeries in that contingent whose treatment by the method of tissue-plasty was related with high risk of lethality. Large scale introduction of tension free hernioplastics caused intensification of the associated problems such as migration, dissection and shortening of the net.

  1. Soil tension mediates isotope fractionation during soil water evaporation

    Science.gov (United States)

    Gaj, Marcel; McDonnell, Jeffrey

    2017-04-01

    Isotope tracing of the water cycle is increasing in its use and usefulness. Many new studies are extracting soil waters and relating these to streamflow, groundwater recharge and plant transpiration. Nevertheless, unlike isotope fractionation factors from open water bodies, soil water fractionation factors are poorly understood and until now, only empirically derived. In contrast to open water evaporation where temperature, humidity and vapor pressure gradient define fractionation (as codified in the well-known Craig and Gordon model), soil water evaporation includes additionally, fractionation by matrix effects. There is yet no physical explanation of kinetic and equilibrium fraction from soil water within the soil profile. Here we present a simple laboratory experiment with four admixtures of soil grain size (from sand to silt to clay). Oven-dried samples were spiked with water of known isotopic composition at different soil water contents. Soils were then stored in sealed bags and the headspace filled with dry air and allowed to equilibrate for 24hours. Isotopic analysis of the headspace vapor was done with a Los Gatos Inc. water vapor isotope analyzer. Soil water potential of subsamples were measured with a water potential meter. We show for the first time that soil tension controls isotope fractionation in the resident soil water. Below a Pf 3.5 the δ-values of 18O and 2H of the headspace vapor is more positive and increases with increasing soil water potential. Surprisingly, we find that the relationship between soil tension and equilibrium fractionation is independent of soil type. However, δ-values of each soil type plot along a distinct evaporation line. These results indicate that equilibrium fractionation is affected by soil tension in addition to temperature. Therefore, at high soil water tension (under dry conditions) equilibrium fractionation is not consistent with current empirical formulations that ignore these effects. These findings may have

  2. Ultrasound Findings in Tension Pneumothorax: A Case Report.

    Science.gov (United States)

    Inocencio, Maxine; Childs, Jeannine; Chilstrom, Mikaela L; Berona, Kristin

    2017-06-01

    Delayed recognition of tension pneumothorax can lead to a mortality of 31% to 91%. However, the classic physical examination findings of tracheal deviation and distended neck veins are poorly sensitive in the diagnosis of tension pneumothorax. Point-of-care ultrasound is accurate in identifying the presence of pneumothorax, but sonographic findings of tension pneumothorax are less well described. We report the case of a 21-year-old man with sudden-onset left-sided chest pain. He was clinically stable without hypoxia or hypotension, and the initial chest x-ray study showed a large pneumothorax without mediastinal shift. While the patient was awaiting tube thoracostomy, a point-of-care ultrasound demonstrated findings of mediastinal shift and a dilated inferior vena cava (IVC) concerning for tension physiology, even though the patient remained hemodynamically stable. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: This case demonstrates a unique clinical scenario of ultrasound evidence of tension physiology in a clinically stable patient. Although this patient was well appearing without hypotension, respiratory distress, tracheal deviation, or distended neck veins, point-of-care ultrasound revealed mediastinal shift and a plethoric IVC. Given that the classic clinical signs of tension pneumothorax are not uniformly present, this case shows how point-of-care ultrasound may diagnose tension pneumothorax before clinical decompensation. Published by Elsevier Inc.

  3. The interfacial tension of the mercury —1 M HClO4− solution interface at high potentials; comparison with double-layer capacitance measurements

    NARCIS (Netherlands)

    Sluyters-Rehbach, M.; Woittiez, W.J.A.; Sluyters, J.H.

    Interfacial tension values have been measured in order to calculate the electrical charge density as a function of potential. The results are in accordance with those obtained from double-layer capacitance data reported earlier2,3, also at highly positive potentials.

  4. Tension and relaxation in the individual.

    Science.gov (United States)

    Newbury, C R

    1979-06-01

    Increasing materialism in society is resulting in more wide spread nervous tension in all age groups. While some degree of nervous tension is necessary in everyday living, its adverse effects require that we must learn to bring it under control. Total tension is shown to have two components: a controllable element arising from factors in the environment and the inbuilt uncontrollable residue which is basic in the individual temperament. The effects of excessive or uncontrolled stress can be classified as 1) emotional reactions such as neurotic behaviour (anxiety hypochondria, hysteria, phobia, depression obsessions and compulsions) or psychotic behaviour and 2) psychosomatic reactions (nervous asthma, headache, insomnia, heart attack). Nervous energy can be wastefully expended by such factors as loss of temper, wrong attitudes to work, job frustration and marital strains. Relaxation is the only positive way to control undesirable nervous tension and its techniques require to be learned. A number of techniques (progressive relaxation, differential relaxation, hypnosis, the use of biofeedback, Yoga and Transcendental Meditation) are described and their application to dental practice is discussed.

  5. High-Flow Nasal Oxygen in Patient With Obstructive Sleep Apnea Undergoing Awake Craniotomy: A Case Report.

    Science.gov (United States)

    Wong, Jaclyn W M; Kong, Amy H S; Lam, Sau Yee; Woo, Peter Y M

    2017-12-15

    Patients with obstructive sleep apnea are frequently considered unsuitable candidates for awake craniotomy due to anticipated problems with oxygenation, ventilation, and a potentially difficult airway. At present, only a handful of such accounts exist in the literature. Our report describes the novel use of high-flow nasal oxygen therapy for a patient with moderate obstructive sleep apnea who underwent an awake craniotomy under deep sedation. The intraoperative application of high-flow nasal oxygen therapy achieved satisfactory oxygenation, maintained the partial carbon dioxide pressure within a reasonable range even during periods of deep sedation, permitted responsive patient monitoring during mapping, and provided excellent patient and surgeon satisfaction.

  6. Steel reinforced composite silicone membranes and its integration to microfluidic oxygenators for high performance gas exchange.

    Science.gov (United States)

    Matharoo, Harpreet; Dabaghi, Mohammadhossein; Rochow, Niels; Fusch, Gerhard; Saraei, Neda; Tauhiduzzaman, Mohammed; Veldhuis, Stephen; Brash, John; Fusch, Christoph; Selvaganapathy, P Ravi

    2018-01-01

    Respiratory distress syndrome (RDS) is one of the main causes of fatality in newborn infants, particularly in neonates with low birth-weight. Commercial extracorporeal oxygenators have been used for low-birth-weight neonates in neonatal intensive care units. However, these oxygenators require high blood volumes to prime. In the last decade, microfluidics oxygenators using enriched oxygen have been developed for this purpose. Some of these oxygenators use thin polydimethylsiloxane (PDMS) membranes to facilitate gas exchange between the blood flowing in the microchannels and the ambient air outside. However, PDMS is elastic and the thin membranes exhibit significant deformation and delamination under pressure which alters the architecture of the devices causing poor oxygenation or device failure. Therefore, an alternate membrane with high stability, low deformation under pressure, and high gas exchange was desired. In this paper, we present a novel composite membrane consisting of an ultra-thin stainless-steel mesh embedded in PDMS, designed specifically for a microfluidic single oxygenator unit (SOU). In comparison to homogeneous PDMS membranes, this composite membrane demonstrated high stability, low deformation under pressure, and high gas exchange. In addition, a new design for oxygenator with sloping profile and tapered inlet configuration has been introduced to achieve the same gas exchange at lower pressure drops. SOUs were tested by bovine blood to evaluate gas exchange properties. Among all tested SOUs, the flat design SOU with composite membrane has the highest oxygen exchange of 40.32 ml/min m 2 . The superior performance of the new device with composite membrane was demonstrated by constructing a lung assist device (LAD) with a low priming volume of 10 ml. The LAD was achieved by the oxygen uptake of 0.48-0.90 ml/min and the CO 2 release of 1.05-2.27 ml/min at blood flow rates ranging between 8 and 48 ml/min. This LAD was shown to increase the

  7. A highly accurate method for determination of dissolved oxygen: Gravimetric Winkler method

    International Nuclear Information System (INIS)

    Helm, Irja; Jalukse, Lauri; Leito, Ivo

    2012-01-01

    Highlights: ► Probably the most accurate method available for dissolved oxygen concentration measurement was developed. ► Careful analysis of uncertainty sources was carried out and the method was optimized for minimizing all uncertainty sources as far as practical. ► This development enables more accurate calibration of dissolved oxygen sensors for routine analysis than has been possible before. - Abstract: A high-accuracy Winkler titration method has been developed for determination of dissolved oxygen concentration. Careful analysis of uncertainty sources relevant to the Winkler method was carried out and the method was optimized for minimizing all uncertainty sources as far as practical. The most important improvements were: gravimetric measurement of all solutions, pre-titration to minimize the effect of iodine volatilization, accurate amperometric end point detection and careful accounting for dissolved oxygen in the reagents. As a result, the developed method is possibly the most accurate method of determination of dissolved oxygen available. Depending on measurement conditions and on the dissolved oxygen concentration the combined standard uncertainties of the method are in the range of 0.012–0.018 mg dm −3 corresponding to the k = 2 expanded uncertainty in the range of 0.023–0.035 mg dm −3 (0.27–0.38%, relative). This development enables more accurate calibration of electrochemical and optical dissolved oxygen sensors for routine analysis than has been possible before.

  8. Current and emerging concepts in muscle tension dysphonia: a 30-month review.

    Science.gov (United States)

    Altman, Kenneth W; Atkinson, Cory; Lazarus, Cathy

    2005-06-01

    The modern theory of hoarseness is that there are multifactorial etiologies contributing to the voice problem. The hypothesis of this study is that muscle tension dysphonia is multifactorial with various contributing etiologies. This project is a retrospective chart review of all patients seen in the Voice Speech and Language Service and Swallowing Center at our institution with a diagnosis of muscle tension (functional hypertensive) dysphonia over a 30-month period. A literature search and review is also performed regarding current and emerging concepts of muscle tension dysphonia. One hundred fifty subjects were identified (60% female, 40% male, with a mean age of 42.3 years). Significant factors in patient history believed to contribute to abnormal voice production were gastroesophageal reflux in 49%, high stress levels in 18%, excessive amounts of voice use in 63%, and excessive loudness demands on voice use in 23%. Otolaryngologic evaluation was performed in 82% of patients, in whom lesions, significant vocal fold edema, or paralysis/paresis was identified in 52.3%. Speech pathology assessment revealed poor breath support, inappropriately low pitch, and visible cervical neck tension in the majority of patients. Inappropriate intensity was observed in 23.3% of patients. This set of multiple contributing factors is discussed in the context of current and emerging understanding of muscle tension dysphonia. Results confirm multifactorial etiologies contributing to hoarseness in the patients identified with muscle tension dysphonia. An interdisciplinary approach to treating all contributing factors portends the best prognosis.

  9. Increased long-term mortality after a high perioperative inspiratory oxygen fraction during abdominal surgery

    DEFF Research Database (Denmark)

    Meyhoff, Christian Sylvest; Jorgensen, Lars N; Wetterslev, Jørn

    2012-01-01

    A high perioperative inspiratory oxygen fraction (80%) has been recommended to prevent postoperative wound infections. However, the most recent and one of the largest trials, the PROXI trial, found no reduction in surgical site infection, and 30-day mortality was higher in patients given 80% oxygen...

  10. Emergency percutaneous needle decompression for tension pneumoperitoneum

    Directory of Open Access Journals (Sweden)

    Körner Markus

    2011-05-01

    Full Text Available Abstract Background Tension pneumoperitoneum as a complication of iatrogenic bowel perforation during endoscopy is a dramatic condition in which intraperitoneal air under pressure causes hemodynamic and ventilatory compromise. Like tension pneumothorax, urgent intervention is required. Immediate surgical decompression though is not always possible due to the limitations of the preclinical management and sometimes to capacity constraints of medical staff and equipment in the clinic. Methods This is a retrospective analysis of cases of pneumoperitoneum and tension pneumoperitoneum due to iatrogenic bowel perforation. All patients admitted to our surgical department between January 2005 and October 2010 were included. Tension pneumoperitoneum was diagnosed in those patients presenting signs of hemodynamic and ventilatory compromise in addition to abdominal distension. Results Between January 2005 and October 2010 eleven patients with iatrogenic bowel perforation were admitted to our surgical department. The mean time between perforation and admission was 36 ± 14 hrs (range 30 min - 130 hrs, between ER admission and begin of the operation 3 hrs and 15 min ± 47 min (range 60 min - 9 hrs. Three out of eleven patients had clinical signs of tension pneumoperitoneum. In those patients emergency percutaneous needle decompression was performed with a 16G venous catheter. This improved significantly the patients' condition (stabilization of vital signs, reducing jugular vein congestion, bridging the time to the start of the operation. Conclusions Hemodynamical and respiratory compromise in addition to abdominal distension shortly after endoscopy are strongly suggestive of tension pneumoperitoneum due to iatrogenic bowel perforation. This is a rare but life threatening condition and it can be managed in a preclinical and clinical setting with emergency percutaneous needle decompression like tension pneumothorax. Emergency percutaneous decompression is no

  11. A DLTS study of the evolution of oxygen precipitates in Si at high temperature and high pressure

    International Nuclear Information System (INIS)

    Antonova, I.V.; Popov, V.P.; Fedina, L.I.; Shaimeev, S.S.; Misiuk, A.

    1996-01-01

    The effect of high hydrostatic pressure on the dissolution of oxygen precipitates introduced beforehand into Si at temperatures of 920-1000 K (over period of 96 h) is investigated by the DLTS method. A measurement procedure, based on the formation of electrically active complexes (interstitial oxygen atom-vacancy) during electron irradiation of the samples, is proposed. It is shown that the precipitates do not decompose when point defects are introduced at room temperature. As the treatment temperature increases (to 1220-1650 K), for the same values of the hydrostatic pressure (up to 1.3 GPa) the intensity of the decomposition of oxygen precipitates increases and at 1650 K they are completely dissolved. Study of the decomposition kinetics showed that hydrostatic pressure raises the limit of solubility of the oxygen atoms Oi and slows down their diffusion. It is determined that the diffusion activation energy Ea, just as the preexponential factor D0, in the expression for the diffusion decrease with increasing hydrostatic pressure, resulting in a lower diffusion. Possible mechanisms for the effect of hydrostatic pressure on oxygen diffusion near a precipitate are discussed

  12. [Diagnostic and therapy of tension-type headache].

    Science.gov (United States)

    Straube, A

    2014-08-01

    Episodic headache of the tension type is the most prevalent primary headache with a lifetime prevalence of about 78 %. Clinical characteristics are a dull, moderate, holocephalic headache without accompanying autonomic or vegetative symptoms. The episodic tension-type headache often lasts only 30 min up to a maximum of a few days. In contrast to this clinically often undemanding headache, chronic tension-type headache can cause considerable disability in patients. The 1-year prevalence is 1-3 % of the population. All therapy strategies combine nonpharmaceutical therapy such as education of the patient, regular aerobic exercise, and psychological treatment (e.g., Jacobson's progressive muscle relaxation etc.) with pharmaceutical treatment such as tricyclic antidepressants or combined serotonergic and noradrenergic antidepressants. Combination therapy has been proven to be more effective than singular strategies; however, the chronic tension-type headache still poses a therapeutic problem.

  13. Manual therapy in adults with tension-type headache: A systematic review.

    Science.gov (United States)

    Cumplido-Trasmonte, C; Fernández-González, P; Alguacil-Diego, I M; Molina-Rueda, F

    2018-03-07

    Tension-type headache is the most common primary headache, with a high prevalence and a considerable socioeconomic impact. Manual physical therapy techniques are widely used in the clinical field to treat the symptoms associated with tension-type headache. This systematic review aims to determine the effectiveness of manual and non-invasive therapies in the treatment of patients with tension-type headache. We conducted a systematic review of randomised controlled trials in the following databases: Brain, PubMed, Web of Science, PEDro, Scopus, CINAHL, and Science Direct. Ten randomised controlled trials were included for analysis. According to these studies, manual therapy improves symptoms, increasing patients' well-being and improving the outcome measures analysed. Manual therapy has positive effects on pain intensity, pain frequency, disability, overall impact, quality of life, and craniocervical range of motion in adults with tension-type headache. None of the techniques was found to be superior to the others; combining different techniques seems to be the most effective approach. Copyright © 2018 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Preliminary tension effect on low-cycle fatigue of 40Kh13 steel in gaseous hydrogen

    International Nuclear Information System (INIS)

    Romaniv, A.N.

    1984-01-01

    Comparative bending tests of specimens deformed by tension at 65, 18 and 30% in hydrogen and vacuum were accomplished to reveal the effect of preliminary tension on low-cycle fatigue strength of 40Kh13 martensitic steel. It was found that small amounts of preliminary strains induced a considerable decrease in low-cycle durability in vacuum and hydrogen which was connected with developing defects arising at the early stages of plastic deformation. A rather high degree of preliminary tension promoted steel homogenization, hydrogen embrittlement decrease and service behaviour improvement

  15. Planck and the local Universe: quantifying the tension

    CERN Document Server

    Verde, Licia; Protopapas, Pavlos

    2013-01-01

    We use the latest Planck constraints, and in particular constraints on the derived parameters (Hubble constant and age of the Universe) for the local universe and compare them with local measurements of the same quantities. We propose a way to quantify whether cosmological parameters constraints from two different experiments are in tension or not. Our statistic, T, is an evidence ratio and therefore can be interpreted with the widely used Jeffrey's scale. We find that in the framework of the LCDM model, the Planck inferred two dimensional, joint, posterior distribution for the Hubble constant and age of the Universe is in "strong" tension with the local measurements; the odds being ~ 1:50. We explore several possibilities for explaining this tension and examine the consequences both in terms of unknown errors and deviations from the LCDM model. In some one-parameter LCDM model extensions, tension is reduced whereas in other extensions, tension is instead increased. In particular, small total neutrino masses ...

  16. Effects of surface tension on tray point efficiencies

    Energy Technology Data Exchange (ETDEWEB)

    Chen, G.X.; Afacan, A.; Chuang, K.T. (Alberta Univ., Edmonton, AB (Canada))

    1994-08-01

    Sieve tray efficiencies for the distillation of methanol/water, acetic acid/water, and cyclohexane/n-heptane mixtures were measured as a function of composition under fixed vapor and liquid rates in a 0.15 m diameter distillation column. The three binary distillation systems used in the study had a wide range of surface tensions measured as a function of composition. From the efficiencies measured, the number of vapor- and liquid-phase transfer units (Ng and Nl) was determined and the effects of surface tension on Ng and Nl were identified. To further verify the results obtained from the distillation column, bubble sizes in froths for air/water, air/methanol, and air/(water + surfactant) systems with different surface tensions were measured. The results show that surface tension has a significant effect on tray efficiency and the number of transfer units. Bubble sizes in the tray froths were mainly determined by surface tension, and bubble breakup and coalescence occur in the froths. 45 refs., 15 figs., 1 tab.

  17. Accounting for oxygen in the renal cortex: a computational study of factors that predispose the cortex to hypoxia.

    Science.gov (United States)

    Lee, Chang-Joon; Gardiner, Bruce S; Ngo, Jennifer P; Kar, Saptarshi; Evans, Roger G; Smith, David W

    2017-08-01

    We develop a pseudo-three-dimensional model of oxygen transport for the renal cortex of the rat, incorporating both the axial and radial geometry of the preglomerular circulation and quantitative information regarding the surface areas and transport from the vasculature and renal corpuscles. The computational model was validated by simulating four sets of published experimental studies of renal oxygenation in rats. Under the control conditions, the predicted cortical tissue oxygen tension ([Formula: see text]) or microvascular oxygen tension (µPo 2 ) were within ±1 SE of the mean value observed experimentally. The predicted [Formula: see text] or µPo 2 in response to ischemia-reperfusion injury, acute hemodilution, blockade of nitric oxide synthase, or uncoupling mitochondrial respiration, were within ±2 SE observed experimentally. We performed a sensitivity analysis of the key model parameters to assess their individual or combined impact on the predicted [Formula: see text] and µPo 2 The model parameters analyzed were as follows: 1 ) the major determinants of renal oxygen delivery ([Formula: see text]) (arterial blood Po 2 , hemoglobin concentration, and renal blood flow); 2 ) the major determinants of renal oxygen consumption (V̇o 2 ) [glomerular filtration rate (GFR) and the efficiency of oxygen utilization for sodium reabsorption (β)]; and 3) peritubular capillary surface area (PCSA). Reductions in PCSA by 50% were found to profoundly increase the sensitivity of [Formula: see text] and µPo 2 to the major the determinants of [Formula: see text] and V̇o 2 The increasing likelihood of hypoxia with decreasing PCSA provides a potential explanation for the increased risk of acute kidney injury in some experimental animals and for patients with chronic kidney disease. Copyright © 2017 the American Physiological Society.

  18. Modeling the oxygen microheterogeneity of tumors for photodynamic therapy dosimetry

    Science.gov (United States)

    Pogue, Brian W.; Paulsen, Keith D.; O'Hara, Julia A.; Hoopes, P. Jack; Swartz, Harold

    2000-03-01

    Photodynamic theory of tumors uses optical excitation of a sensitizing drug within tissue to produce large deposits of singlet oxygen, which are thought to ultimately cause the tumor destruction. Predicting dose deposition of singlet oxygen in vivo is challenging because measurement of this species in vivo is not easily achieved. But it is possible to follow the concentration of oxygen in vivo, and so measuring the oxygen concentration transients during PDT may provide a viable method of estimating the delivered dose of singlet oxygen. However modeling the microscopic heterogeneity of the oxygen distribution within a tumor is non-trivial, and predicting the microscopic dose deposition requires further study, but this study present the framework and initial calibration needed or modeling oxygen transport in complex geometries. Computational modeling with finite elements provides a versatile structure within which oxygen diffusion and consumption can be modeled within realistic tissue geometries. This study develops the basic tools required to simulate a tumor region, and examines the role of (i) oxygen supply and consumption rates, (ii) inter- capillary spacing, (iii) photosensitizer distribution, and (iv) differences between simulated tumors and those derived directly from histology. The result of these calculations indicate that realistic tumor tissue capillary networks can be simulated using the finite element method, without excessive computational burden for 2D regions near 1 mm2, and 3D regions near 0.1mm3. These simulations can provide fundamental information about tissue and ways to implement appropriate oxygen measurements. These calculations suggest that photodynamic therapy produces the majority of singlet oxygen in and near the blood vessels, because these are the sites of highest oxygen tension. These calculations support the concept that tumor vascular regions are the major targets for PDT dose deposition.

  19. An automatic tension measurement system of MWPC wires

    International Nuclear Information System (INIS)

    D'Antone, I.; Lolli, M.; Torromeo, G.

    1992-01-01

    An electronic system is presented for automatic mechanical tension measurement to test wire chambers. The developed system works in the tension range from 50 g to 300 g; this large working range is obtained by using a microcontroller that performs a digital control on the bridge of an oscillator containing the wire of which the tension has to be measured. The microcontroller automatically brings the system towards the oscillation condition and subsequently, measuring the frequency, it evaluates, displays and sends to a host computer the value of the mechanical tension of the wires. The system is precise and allows fast measurements. A description of the hardware and software design is given. (orig.)

  20. EXPERIENCE WITH THE OPEN TENSION-FREE HERNIA REPAIR

    Directory of Open Access Journals (Sweden)

    Slavko Rakovec

    2002-03-01

    Full Text Available Background. All old techniques of herniorrhaphy involve approximation of tissues under tension, which accounts for their unreliability. Therefore the recovery time is long and the recurrence rate unacceptably high. The new methods using a mesh patch of polypropylene allow for a tensionfree repair, which is much more reliable. So they are associated with a shorter recovery time and carry a low probability of recurrence. The tension-free repair can be accomplished in an open manner, by placing the mesh through an open incision, or by the endoscopic technique, which involves placing the mesh from within by laparoscopic instruments. The open tension-free procedures can be performed with the use of stitches (according to Lichtenstein or without them (sutureless techniques. Stitching the mesh may cause problems due to maldistribution of tension between the mesh and the patient’s tissues, the occurrence of neuralgia or the development of inflammatory granuloma. Therefore sutureless procedures are increasingly performed. They usually require, besides the use of a mesh patch, also the use of a dart plug made of the same material.Methods. The open tension-free methods of hernia repair have been used at our Department since 1994. The first 77 operations were performed by Lichtenstein technique. The mean postoperative hospital stay was 3.4 days and the mean work restriction period was 3 weeks. In the middle of the year 1995, we shifted to suturless technique. By the end of the year 2000, we had performed 768 operations. The average postoperative hospital stay was 1.2 days and the average recovery time was 10 days.Results. In the first group of 77 hernia repairs performed by the Lichtenstein procedure serious complications were noted in six patients: bleeding in one, long-lasting neuralgia in two, and purulent granuloma, appearing long after discharge from the hospital, in three. There were no recurrences. In the second group of 768 hernia repairs

  1. Effects of anesthetic agents on brain blood oxygenation level revealed with ultra-high field MRI

    International Nuclear Information System (INIS)

    Ciobanu, Luisa; Reynaud, Olivier; Le Bihan, Denis; Uhrig, Lynn; Jarraya, Bechir

    2012-01-01

    During general anesthesia it is crucial to control systemic hemodynamics and oxygenation levels. However, anesthetic agents can affect cerebral hemodynamics and metabolism in a drug-dependent manner, while systemic hemodynamics is stable. Brain-wide monitoring of this effect remains highly challenging. Because T2'*-weighted imaging at ultra-high magnetic field strengths benefits from a dramatic increase in contrast to noise ratio, we hypothesized that it could monitor anesthesia effects on brain blood oxygenation. We scanned rat brains at 7 T and 17.2 T under general anesthesia using different anesthetics (isoflurane, ketamine-xylazine, medetomidine). We showed that the brain/vessels contrast in T2'*- weighted images at 17.2 T varied directly according to the applied pharmacological anesthetic agent, a phenomenon that was visible, but to a much smaller extent at 7 T. This variation is in agreement with the mechanism of action of these agents. These data demonstrate that preclinical ultra-high field MRI can monitor the effects of a given drug on brain blood oxygenation level in the absence of systemic blood oxygenation changes and of any neural stimulation. (authors)

  2. Oxygen diffusion in high-Tc superconductors

    International Nuclear Information System (INIS)

    Rothman, S.J.; Routbort, J.L.

    1992-07-01

    The cuprate superconductors are fascinating not only because of their technical promise, but also because of their structures, especially the anisotropy of the crystal lattice. There are some structural similarities among these compounds, but also significant differences. Measurements of the oxygen tracer diffusion coefficients have been carried out as a function of temperature, oxygen partial pressure, crystal orientation, and doping in the La-Sr-Cu-0, Y-Ba-Cu-0, and Bi-Sr-Ca-Cu-0 systems. These measurements have revealed a variety of defect mechanisms operating in these compounds; the exact nature of the mechanism depends on the details of the structure

  3. Tension Hydrothorax Related to Disseminated Endometriosis

    Directory of Open Access Journals (Sweden)

    AnnaKate Deal, MD

    2016-01-01

    Full Text Available We present the case of a 34-year-old woman presenting to the emergency department (ED with dyspnea, cough, and fever. She was found to have a tension hydrothorax and was treated with ultrasound-guided thoracentesis in the ED. Subsequent inpatient evaluation showed the patient had disseminated endometriosis. Tension hydrothorax has not been previously described in the literature as a complication of this disease.

  4. Surface tension of liquid Al-Cu binary alloys.

    OpenAIRE

    Schmitz, Julianna; Brillo, Jürgen; Egry, Ivan; Schmid-Fetzer, Rainer

    2009-01-01

    Surface tension data of liquid Al–Cu binary alloys have been measured contactlessly using the technique of electromagnetic levitation. A digital CMOS-camera (400 fps) recorded image sequences of the oscillating liquid sample and surface tensions were determined from analysis of the frequency spectra. Measurements were performed for samples covering the entire range of composition and precise data were obtained in a broad temperature range. It was found that the surface tensions can ...

  5. Surface tension-induced high aspect-ratio PDMS micropillars with concave and convex lens tips

    KAUST Repository

    Li, Huawei; Fan, Yiqiang; Yi, Ying; Foulds, Ian G.

    2013-01-01

    This paper reports a novel method for the fabrication of 3-dimensional (3D) Polydimethylsiloxane (PDMS) micropillars with concave and convex lens tips in a one-step molding process, using a CO2 laser-machined Poly(methyl methacrylate) (PMMA) mold with through holes. The PDMS micropillars are 4 mm high and have an aspect ratio of 251. The micropillars are formed by capillary force drawing up PDMS into the through hole mold. The concave and convex lens tips of the PDMS cylindrical micropillars are induced by surface tension and are controllable by changing the surface wetting properties of the through holes in the PMMA mold. This technique eliminates the requirements of expensive and complicated facilities to prepare a 3D mold, and it provides a simple and rapid method to fabricate 3D PDMS micropillars with controllable dimensions and tip shapes. © 2013 IEEE.

  6. Surface tension-induced high aspect-ratio PDMS micropillars with concave and convex lens tips

    KAUST Repository

    Li, Huawei

    2013-04-01

    This paper reports a novel method for the fabrication of 3-dimensional (3D) Polydimethylsiloxane (PDMS) micropillars with concave and convex lens tips in a one-step molding process, using a CO2 laser-machined Poly(methyl methacrylate) (PMMA) mold with through holes. The PDMS micropillars are 4 mm high and have an aspect ratio of 251. The micropillars are formed by capillary force drawing up PDMS into the through hole mold. The concave and convex lens tips of the PDMS cylindrical micropillars are induced by surface tension and are controllable by changing the surface wetting properties of the through holes in the PMMA mold. This technique eliminates the requirements of expensive and complicated facilities to prepare a 3D mold, and it provides a simple and rapid method to fabricate 3D PDMS micropillars with controllable dimensions and tip shapes. © 2013 IEEE.

  7. A cohesion/tension mechanism explains the gating of water channels (aquaporins) in Chara internodes by high concentration.

    Science.gov (United States)

    Ye, Qing; Wiera, Boguslaw; Steudle, Ernst

    2004-02-01

    Isolated internodes of Chara corallina have been used to study the gating of aquaporins (water channels) in the presence of high concentrations of osmotic solutes of different size (molecular weight). Osmolytes were acetone and three glycol ethers: ethylene glycol monomethyl ether (EGMME), diethylene glycol monomethyl ether (DEGMME), and triethylene glycol monoethyl ether (TEGMEE). The 'osmotic efficiency' of osmolytes was quite different. Their reflection coefficients ranged between 0.15 (acetone), 0.59 (EGMME), 0.78 (DEGMME), and 0.80 (TEGMEE). Bulk water permeability (Lp) and diffusive permeabilities (Ps) of heavy water (HDO), hydrogen peroxide (H2O2), acetone, and glycol ethers (EGMME, DEGMME, and TEGMEE) were measured using a cell pressure probe. Cells were treated with different concentrations of osmotic solutes of up to 800 mM ( approximately 2.0 MPa of osmotic pressure). Inhibition of aquaporin activity increased with both increasing concentration and size of solutes (reflection coefficients). As cell Lp decreased, Ps increased, indicating that water and solutes used different passages across the plasma membrane. Similar to earlier findings of an osmotic gating of ion channels, a cohesion/tension model of the gating of water channels in Chara internodes by high concentration is proposed. According to the model, tensions (negative pressures) within water channels affected the open/closed state by changing the free energy between states and favoured a distorted/collapsed rather than the open state. They should have differed depending on the concentration and size of solutes that are more or less excluded from aquaporins. The bigger the solute, the lower was the concentration required to induce a reversible closure of aquaporins, as predicted by the model.

  8. Irradiation of cells by single and double pulses of high intensity radiation: oxygen sensitization and diffusion kinetics

    International Nuclear Information System (INIS)

    Epp, E.R.; Ling, C.C.; Weiss, H.

    1976-01-01

    This paper discusses advances made on both experimental and theoretical approaches involving single and double pulses of high intensity ionizing radiation delivered to cultured bacterial and mammalian cells where the effect of oxygen is concerned. Information gained on the lifetime of oxygen-sensitive species suspected to be produced in critical molecules in irradiated cells and perhaps intimately related to the still unknown mechanisms of oxygen sensitization is described. The diffusion characteristics of oxygen at the cellular level obtained from experimental data are discussed. Current knowledge on intracellular radiolytic oxygen depletion is also presented. Future work on the use of high intensity pulsed radiation as a tool in cellular radiobiological research is outlined. It is expected that obtaining knowledge of the time available for damaged molecules to enter into chemical reactions may lead to insights into the mechanisms of radiation injury in cells, such as those involved in the oxygen effect. (Auth.)

  9. Embracing Tensions in Feminist Organizational Communication Pedagogies

    Science.gov (United States)

    Linabary, Jasmine R.; Long, Ziyu; Mouton, Ashton; Rao, Ranjani L.; Buzzanell, Patrice M.

    2017-01-01

    Feminist pedagogies hold potential to create more inclusive and transformative classrooms. Adopting a tension-centered approach, we draw on our individual and collective reflections on the design and instruction of a multi-section undergraduate organizational communication course to build an autoethnographic account of the tensions associated with…

  10. Tension Pneumothorax following an Accidental Kerosene Poisoning ...

    African Journals Online (AJOL)

    Tension pneumothorax is a rare complication following an accidental kerosene poisoning. In such situation, a bed-side needle thoracocentesis is performed because of its potential of becoming fatal; hence its clinical importance. A case of 15 month old boy with tension pneumothorax following accidental kerosene ...

  11. High-temperature vaporization behavior of oxygen-deficient thoria

    International Nuclear Information System (INIS)

    Ackermann, R.J.; Tetenbaum, M.

    1979-01-01

    The experimental results of the present study on the vaporization behavior of oxygen-deficient thoria are directed toward a more precise and detailed study of the lower phase boundary (l.p.b.) and congruently vaporizing composition (c.v.c), and intermediate compositions, and the corresponding oxygen potentials and total pressure at temperatures above 2000K. The l.p.b. and c.v.c. values were found to fit an equation of the form log x = A + (B/T), where x is the stoichiometric defect in ThO 2 -x. Oxygen potentials corresponding to the l.p.b. and c.v.c. have been estimated from vapor pressures and thermodynamic data. A very sharp decrease in oxygen potential occurs when thoria isreduced only slightly from the stoichiometric composition. In the temperature range from 2400 to 2655 K, the oxygen partial pressure dependency of x in ThO 2 -x was found to be approximately proportional to PO 2 - 1 /4to PO 2 - 1 /. The small extent of reduction over a wide range of oxygen potentials at these temperatures is a clear illustration of the higher stability of the ThO 2 -x phase compared with that of UO 2 -x. Values of ΔHO 2 and ΔSO 2 have been estimated for selected compositions from the dependence of the measured oxygen potential on temperature. Estimates of the standard free energy of formation of bivariant ThO 2 -x compositions have been made. A substantial increase in the total pressure of thorium-bearing species occurs when stoichiometric thoria is reduced toward the lower phase boundary. (orig.) [de

  12. A novel approach to pipeline tensioner modeling

    Energy Technology Data Exchange (ETDEWEB)

    O' Grady, Robert; Ilie, Daniel; Lane, Michael [MCS Software Division, Galway (Ireland)

    2009-07-01

    As subsea pipeline developments continue to move into deep and ultra-deep water locations, there is an increasing need for the accurate prediction of expected pipeline fatigue life. A significant factor that must be considered as part of this process is the fatigue damage sustained by the pipeline during installation. The magnitude of this installation-related damage is governed by a number of different agents, one of which is the dynamic behavior of the tensioner systems during pipe-laying operations. There are a variety of traditional finite element methods for representing dynamic tensioner behavior. These existing methods, while basic in nature, have been proven to provide adequate forecasts in terms of the dynamic variation in typical installation parameters such as top tension and sagbend/overbend strain. However due to the simplicity of these current approaches, some of them tend to over-estimate the frequency of tensioner pay out/in under dynamic loading. This excessive level of pay out/in motion results in the prediction of additional stress cycles at certain roller beds, which in turn leads to the prediction of unrealistic fatigue damage to the pipeline. This unwarranted fatigue damage then equates to an over-conservative value for the accumulated damage experienced by a pipeline weld during installation, and so leads to a reduction in the estimated fatigue life for the pipeline. This paper describes a novel approach to tensioner modeling which allows for greater control over the velocity of dynamic tensioner pay out/in and so provides a more accurate estimation of fatigue damage experienced by the pipeline during installation. The paper reports on a case study, as outlined in the proceeding section, in which a comparison is made between results from this new tensioner model and from a more conventional approach. The comparison considers typical installation parameters as well as an in-depth look at the predicted fatigue damage for the two methods

  13. High-resolution spectra of stars in globular clusters. VI - Oxygen-deficient red giant stars in M13

    International Nuclear Information System (INIS)

    Brown, J.A.; Wallerstein, G.; Oke, J.B.

    1991-01-01

    From high-resolution, high signal-to-noise spectra, abundances of carbon, nitrogen, and oxygen and the C-12/C-13 ratio for five red giants in M13, including star II-67, which has previously been reported to be deficient in oxygen have been determined. Three of the five stars exhibit substantial oxygen deficiencies; O/Fe values range from +0.5 to less than about 0.3. The sum of the CNO nuclides is the same for all stars, which is interpreted as evidence that mixing of CNO-cycled material into the envelope is the cause of the variations in oxygen abundance. 41 refs

  14. Long term high flow heated oxygen treatment in COPD – lung function and physical ability

    DEFF Research Database (Denmark)

    Weinreich, Ulla; Storgaard, Line; Hockey, Hans

    2017-01-01

    Introduction: Long term oxygen therapy (LTOT) improves survival in patients with COPD with resting hypoxemia. Despite this, a progressive loss of lung function and physical ability is expected in COPD. The AIRVO device delivers nasal high flow (NHF) warmed and humidified oxygen-enriched air, 20...

  15. Length and elasticity of side reins affect rein tension at trot.

    Science.gov (United States)

    Clayton, Hilary M; Larson, Britt; Kaiser, LeeAnn J; Lavagnino, Michael

    2011-06-01

    This study investigated the horse's contribution to tension in the reins. The experimental hypotheses were that tension in side reins (1) increases biphasically in each trot stride, (2) changes inversely with rein length, and (3) changes with elasticity of the reins. Eight riding horses trotted in hand at consistent speed in a straight line wearing a bit and bridle and three types of side reins (inelastic, stiff elastic, compliant elastic) were evaluated in random order at long, neutral, and short lengths. Strain gauge transducers (240 Hz) measured minimal, maximal and mean rein tension, rate of loading and impulse. The effects of rein type and length were evaluated using ANOVA with Bonferroni post hoc tests. Rein tension oscillated in a regular pattern with a peak during each diagonal stance phase. Within each rein type, minimal, maximal and mean tensions were higher with shorter reins. At neutral or short lengths, minimal tension increased and maximal tension decreased with elasticity of the reins. Short, inelastic reins had the highest maximal tension and rate of loading. Since the tension variables respond differently to rein elasticity at different lengths, it is recommended that a set of variables representing different aspects of rein tension should be reported. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. The use of high-flow nasal oxygen in COPD patients

    Directory of Open Access Journals (Sweden)

    Silva Santos P

    2016-09-01

    Full Text Available Pedro Silva Santos,1 Antonio M Esquinas21Pulmonology Unit, Centro Hospitalar e Universitário de Coimbra – Hospitais da Universidade de Coimbra, Coimbra, Portugal; 2Internsive Care Unit, Hospital Morales Meseguer, Múrcia, SpainHigh-flow nasal cannula (HFNC oxygen therapy is an innovative and useful mode for the treatment of patients with respiratory failure.1–3 It delivers heated and humidified air providing higher and more expected gas flow rates and fraction inspired oxygen (FiO2 than traditional oxygen therapy.2     We read the article by Bräunlich et al1 carefully and congratulate the authors on their study about the use of nasal high-flow therapy in COPD patients. There are, however, some limitations to the study that need to be considered.    First, this study has a small number of patients, particularly in groups A and B, which in our opinion will affect the comparison of data with the group C that contains a greater variety of patients with more severe outcomes, including forced expiratory volume in 1 second and forced vital capacity. Second, as a study on mean airway pressure, it would be interesting to evaluate partial pressure of CO2 with higher flows.    Third, one of the aims of this study was to characterize changes in hypercapnia, so it is not correct to include nonhypercapnic patients. Fourth, it would be interesting to know the FiO2 that was given and whether the patients had domiciliary oxygen or noninvasive ventilation, as most of them are hypercapnic patients. Finally, regarding comfort and dyspnea scale, HFNC showed better results, which may increase its use when intolerant to noninvasive ventilation.    In short, HFNC is an interesting mode for the future treatment of COPD patients with respiratory failure, which may lead to larger and randomized trials to confirm this indication.View original paper by Bräunlich et al.

  17. Tension test system for irradiated small specimens operated by remote control

    International Nuclear Information System (INIS)

    Okada, Akira

    1993-01-01

    A robot-based tension test system has been developed to aid in the mechanical testing of highly radioactive specimens. This system reduces radiation hazards from specimens and allows for the uniform precision of testing results independent of experimenters' skills. The robot system is designed to accommodate a miniaturized tension specimen with a gage section 5.5 by 1.2 mm, with a total length and width of 12.5 and 2.3 mm, respectively, and thickness of about 0.2 mm. The system is composed of a manipulating robot, a vibrational-type specimen feeder, a rotating-type specimen tray, a specimen observation system, a simulated tension text fixture, and a microcomputer for controlling the system. This system accomplishes specimen arrangement in the specimen tray, specimen transportation and loading to the test fixture and testing, and removal of the broken specimen from the fixture. These procedures are performed quickly, safely, and with uniform testing precision by computer control remotely by an unskilled experimenter

  18. Highly sensitive time resolved singlet oxygen luminescence detection using LEDs as the excitation source

    International Nuclear Information System (INIS)

    Hackbarth, S; Schlothauer, J; Preuss, A; Röder, B

    2013-01-01

    For the first time singlet oxygen luminescence kinetics in living cells were detected at high precision using LED light for excitation. As LED technology evolves, the light intensity emitted by standard LEDs allows photosensitized singlet oxygen luminescence detection in solution and cell suspensions. We present measurements superior to those of most actual laser powered setups regarding precision of singlet oxygen kinetics in solutions and cell suspensions. Data presented here show that LED based setups allow the determination of the photosensitizer triplet and singlet oxygen decay times in vitro with an accuracy of 0.1 μs. This enables monitoring of the photosensitizer efficiency and interaction with the cellular components using illumination doses small enough not to cause cell death. (letter)

  19. Normobaric pulmonary oxygen toxicity : experimental studies on the mechanism of the protective role of endotoxin and the role of surfactant.

    NARCIS (Netherlands)

    J. Klein (Jan)

    1991-01-01

    textabstractAdministration of above-ambient oxygen tensions, necessary for treatment of severe hypoxemia caused by respiratory failure or acute lung injury, is potentially toxic for the lungs. This thesis is based on six articles dealing with this topic: one review article and five articles

  20. Effect of potential attraction term on surface tension of ionic liquids

    Science.gov (United States)

    Vaziri, N.; Khordad, R.; Rezaei, G.

    2018-03-01

    In this work, we have studied the effect of attraction term of molecular potential on surface tension of ionic liquids (ILs). For this purpose, we have introduced two different potential models to obtain analytical expressions for the surface tension of ILs. The introduced potential models have different attraction terms. The obtained surface tensions in this work have been compared with other theoretical methods and also experimental data. Using the calculated surface tension, the sound velocity is also estimated. We have studied the structural effects on the surface tensions of imidazolium-based ionic liquids. It is found that the cation alkyl chain length and the anion size play important roles to the surface tension of the selected ionic liquids. The calculated surface tensions show a good harmony with experimental data. It is clear that the attraction term of molecular potential has an important role on surface tension and sound velocity of our system.

  1. Substrate stiffness and oxygen as regulators of stem cell differentiation during skeletal tissue regeneration: a mechanobiological model.

    Directory of Open Access Journals (Sweden)

    Darren Paul Burke

    Full Text Available Extrinsic mechanical signals have been implicated as key regulators of mesenchymal stem cell (MSC differentiation. It has been possible to test different hypotheses for mechano-regulated MSC differentiation by attempting to simulate regenerative events such as bone fracture repair, where repeatable spatial and temporal patterns of tissue differentiation occur. More recently, in vitro studies have identified other environmental cues such as substrate stiffness and oxygen tension as key regulators of MSC differentiation; however it remains unclear if and how such cues determine stem cell fate in vivo. As part of this study, a computational model was developed to test the hypothesis that substrate stiffness and oxygen tension regulate stem cell differentiation during fracture healing. Rather than assuming mechanical signals act directly on stem cells to determine their differentiation pathway, it is postulated that they act indirectly to regulate angiogenesis and hence partially determine the local oxygen environment within a regenerating tissue. Chondrogenesis of MSCs was hypothesized to occur in low oxygen regions, while in well vascularised regions of the regenerating tissue a soft local substrate was hypothesised to facilitate adipogenesis while a stiff substrate facilitated osteogenesis. Predictions from the model were compared to both experimental data and to predictions of a well established computational mechanobiological model where tissue differentiation is assumed to be regulated directly by the local mechanical environment. The model predicted all the major events of fracture repair, including cartilaginous bridging, endosteal and periosteal bony bridging and bone remodelling. It therefore provides support for the hypothesis that substrate stiffness and oxygen play a key role in regulating MSC fate during regenerative events such as fracture healing.

  2. Tension layer winding of cable-in-conduit conductor

    International Nuclear Information System (INIS)

    Devernoe, A.; Ciancetta, G.; King, M.; Parizh, M.; Painter, T.; Miller, J.

    1996-01-01

    A 710 mm i.d. by 440 mm long, 6 layer Cable-in-Conduit (CIC) coil was precision tension layer wound with Incoloy 908 jacketed conductor to model winding technology that will be used for the Nb 3 Sn outsert coils of the 45 Tesla Hybrid Magnet Project at the US National High Magnetic Field Laboratory. This paper reports on the set up of a new winding facility with unique capabilities for insulating and winding long length CIC conductor and on special procedures which were developed to wind and support layer to layer transitions and to safely form conductor into and out of the winding. Analytical methods used to predict conduit keystoning, springback and back tensioning requirements before winding are reported in comparison to results obtained during winding and actual winding build-up dimensions on a layer by layer basis in comparison to design requirements

  3. Tension Stiffened and Tendon Actuated Manipulator

    Science.gov (United States)

    Doggett, William R. (Inventor); Dorsey, John T. (Inventor); Ganoe, George G. (Inventor); King, Bruce D. (Inventor); Jones, Thomas C. (Inventor); Mercer, Charles D. (Inventor); Corbin, Cole K. (Inventor)

    2015-01-01

    A tension stiffened and tendon actuated manipulator is provided performing robotic-like movements when acquiring a payload. The manipulator design can be adapted for use in-space, lunar or other planetary installations as it is readily configurable for acquiring and precisely manipulating a payload in both a zero-g environment and in an environment with a gravity field. The manipulator includes a plurality of link arms, a hinge connecting adjacent link arms together to allow the adjacent link arms to rotate relative to each other and a cable actuation and tensioning system provided between adjacent link arms. The cable actuation and tensioning system includes a spreader arm and a plurality of driven and non-driven elements attached to the link arms and the spreader arm. At least one cable is routed around the driven and non-driven elements for actuating the hinge.

  4. Radial transport of high-energy oxygen ions into the deep inner magnetosphere observed by Van Allen Probes

    Science.gov (United States)

    Mitani, K.; Seki, K.; Keika, K.; Gkioulidou, M.; Lanzerotti, L. J.; Mitchell, D. G.; Kletzing, C.

    2017-12-01

    It is known that proton is main contributor of the ring current and oxygen ions can make significant contribution during major magnetic storms. Ions are supplied to the ring current by radial transport from the plasma sheet. Convective transport of lower-energy protons and diffusive transport of higher-energy protons were reported to contribute to the storm-time and quiet-time ring current respectively [e.g., Gkioulidou et al., 2016]. However, supply mechanisms of the oxygen ions are not clear. To characterize the supply of oxygen ions to the ring current during magnetic storms, we studied the properties of energetic proton and oxygen ion phase space densities (PSDs) for specific magnetic moment (μ) during the April 23-25, 2013, geomagnetic storm observed by the Van Allen Probes mission. We here report on radial transport of high-energy (μ ≥ 0.5 keV/nT) oxygen ions into the deep inner magnetosphere during the late main phase of the magnetic storm. Since protons show little change during this period, this oxygen radial transport is inferred to cause the development of the late main phase. Enhancement of poloidal magnetic fluctuations is simultaneously observed. We estimated azimuthal mode number ≤5 by using cross wavelet analysis with ground-based observation of IMAGE ground magnetometers. The fluctuations can resonate with drift and bounce motions of the oxygen ions. The results suggest that combination of the drift and drift-bounce resonances is responsible for the radial transport of high-energy oxygen ions into the deep inner magnetosphere. We also report on the radial transport of the high-energy oxygen ions into the deep inner magnetosphere during other magnetic storms.

  5. Axons Pull on the Brain, But Tension Does Not Drive Cortical Folding

    Science.gov (United States)

    Xu, Gang; Knutsen, Andrew K.; Dikranian, Krikor; Kroenke, Christopher D.; Bayly, Philip V.; Taber, Larry A.

    2011-01-01

    During human brain development, the cerebral cortex undergoes substantial folding, leading to its characteristic highly convoluted form. Folding is necessary to accommodate the expansion of the cerbral cortex; abnormal cortical folding is linked to various neurological disorders, including schizophrenia, epilepsy, autism and mental retardation. Although this process requires mechanical forces, the specific force-generating mechanisms that drive folding remain unclear. The two most widely accepted hypotheses are (1) folding is caused by differential growth of the cortex and (2) folding is caused by mechanical tension generated in axons. Direct evidence supporting either theory, however, is lacking. Here we show that axons are indeed under considerable tension in the developing ferret brain, but the patterns of tissue stress are not consistent with a causal role for axonal tension. In particular, microdissection assays reveal that significant tension exists along axons aligned circumferentially in subcortical white matter tracts, as well as those aligned radially inside developing gyri (outward folds). Contrary to previous speculation, however, axonal tension is not directed across developing gyri, suggesting that axon tension does not drive folding. On the other hand, using computational (finite element) models, we show that differential cortical growth accompanied by remodeling of the subplate leads to outward folds and stress fields that are consistent with our microdissection experiments, supporting a mechanism involving differential growth. Local perturbations, such as temporal differences in the initiation of cortical growth, can ensure consistent folding patterns. This study shows that a combination of experimental and computational mechanics can be used to evaluate competing hypotheses of morphogenesis, and illuminate the biomechanics of cortical folding. PMID:20590291

  6. Actin filaments as tension sensors.

    Science.gov (United States)

    Galkin, Vitold E; Orlova, Albina; Egelman, Edward H

    2012-02-07

    The field of mechanobiology has witnessed an explosive growth over the past several years as interest has greatly increased in understanding how mechanical forces are transduced by cells and how cells migrate, adhere and generate traction. Actin, a highly abundant and anomalously conserved protein, plays a large role in forming the dynamic cytoskeleton that is so essential for cell form, motility and mechanosensitivity. While the actin filament (F-actin) has been viewed as dynamic in terms of polymerization and depolymerization, new results suggest that F-actin itself may function as a highly dynamic tension sensor. This property may help explain the unusual conservation of actin's sequence, as well as shed further light on actin's essential role in structures from sarcomeres to stress fibers. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Oxygen delivery and consumption during on-bypass cabg in htea and central analgesia

    Directory of Open Access Journals (Sweden)

    Віталій Олексійович Собокарь

    2015-04-01

    Full Text Available Objective. Despite some advantages, the use of high thoracic epidural anesthesia (HTEA during on-bypass cardiac surgery may be discouraged by fear of adverse hemodynamic effects and associated disturbances of oxygen delivery.Aim. To compare oxygen delivery and consumption during on-bypass coronary artery bypass grafting in settings of HTEA and central analgesia (CA.Methods. 132 patients were assigned into two groups – study group (n=85, where the surgery was performed under HTEA and control group (n=47 - where the surgery was carried out under CA. Using data of transesophageal cardiac ultrasound and blood oximetry blood oxygen delivery (DO2, oxygen consumption (VO2, oxygen extraction coefficient (CEO2 were calculated at four stages of the surgery: after induction, sternotomy, cardiopulmonary bypass and at the end of the surgery.Results. In the initial stages of the surgery DO2 and VO2 were reduced relative to reference values with a tendency to increase in the course of the operation and achievement of the normal or supernormal level (VO2, study group in the final stage. The decrease was due to moderate hypodynamic circulation and hemodilution. After sternotomy DO2 in the study group was higher than that of the control: 356 (279; 458 vs 317±89 ml·min-1·m-2, (р=0,021. After cardiopulmonary bypass oxygen saturation of venous blood (SatvO2, in the study group was 71 ± 9 % compared with 68 ± 10 % in the control group. At the end of the surgery SatvO2 in the study group was 71 (66; 75 vs 59 (53; 70 % in the control (р = 0,005 and oxygen tension of venous blood (РvО2 was correspondingly 39 ± 6 and 33 (30; 38 mm Hg (р = 0,027. Despite the decrease in DO2 and VO2, oxygen extraction indices - CEO2, pvO2, SatvO2, and remained within the reference range, except that of the control group at the end of the surgery. Furthermore, at no stage lactate rise or acid-base deviations was observed in the both groups.Conclusions. In patients operated

  8. In situ droplet surface tension and viscosity measurements in gas metal arc welding

    International Nuclear Information System (INIS)

    Bachmann, B; Siewert, E; Schein, J

    2012-01-01

    In this paper, we present an adaptation of a drop oscillation technique that enables in situ measurements of thermophysical properties of an industrial pulsed gas metal arc welding (GMAW) process. Surface tension, viscosity, density and temperature were derived expanding the portfolio of existing methods and previously published measurements of surface tension in pulsed GMAW. Natural oscillations of pure liquid iron droplets are recorded during the material transfer with a high-speed camera. Frame rates up to 30000 fps were utilized to visualize iron droplet oscillations which were in the low kHz range. Image processing algorithms were employed for edge contour extraction of the droplets and to derive parameters such as oscillation frequencies and damping rates along different dimensions of the droplet. Accurate surface tension measurements were achieved incorporating the effect of temperature on density. These are compared with a second method that has been developed to accurately determine the mass of droplets produced during the GMAW process which enables precise surface tension measurements with accuracies up to 1% and permits the study of thermophysical properties also for metals whose density highly depends on temperature. Thermophysical properties of pure liquid iron droplets formed by a wire with 1.2 mm diameter were investigated in a pulsed GMAW process with a base current of 100 A and a pulse current of 600 A. Surface tension and viscosity of a sample droplet were 1.83 ± 0.02 N m -1 and 2.9 ± 0.3 mPa s, respectively. The corresponding droplet temperature and density are 2040 ± 50 K and 6830 ± 50 kg m -3 , respectively. (paper)

  9. High impact of uranyl ions on carrying-releasing oxygen capability of hemoglobin-based blood substitutes

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Li; Du, Lili; Liu, Wenyuan; Liu, Zhichao [Northwest Institute of Nuclear Technology, Xi' an, Shaanxi (China); Jia, Yi; Li, Junbai [Beijing National Laboratory for Molecular Sciences, CAS Key Laboratory of Colloid Interface and Chemical Thermodynamics, Institute of Chemistry, Chinese Academy of Sciences, Beijing (China)

    2015-01-07

    The effect of radioactive UO{sub 2}{sup 2+} on the oxygen-transporting capability of hemoglobin-based oxygen carriers has been investigated in vitro. The hemoglobin (Hb) microspheres fabricated by the porous template covalent layer-by-layer (LbL) assembly were utilized as artificial oxygen carriers and blood substitutes. Magnetic nanoparticles of iron oxide (Fe{sub 3}O{sub 4}) were loaded in porous CaCO{sub 3} particles for magnetically assisted chemical separation (MACS). Through the adsorption spectrum of magnetic Hb microspheres after adsorbing UO{sub 2}{sup 2+}, it was found that UO{sub 2}{sup 2+} was highly loaded in the magnetic Hb microspheres, and it shows that the presence of UO{sub 2}{sup 2+} in vivo destroys the structure and oxygen-transporting capability of Hb microspheres. In view of the high adsorption capacity of UO{sub 2}{sup 2+}, the as-assembled magnetic Hb microspheres can be considered as a novel, highly effective adsorbent for removing metal toxins from radiation-contaminated bodies, or from nuclear-power reactor effluent before discharge into the environment. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  10. Effects of anesthetic agents on brain blood oxygenation level revealed with ultra-high field MRI.

    Directory of Open Access Journals (Sweden)

    Luisa Ciobanu

    Full Text Available During general anesthesia it is crucial to control systemic hemodynamics and oxygenation levels. However, anesthetic agents can affect cerebral hemodynamics and metabolism in a drug-dependent manner, while systemic hemodynamics is stable. Brain-wide monitoring of this effect remains highly challenging. Because T(2*-weighted imaging at ultra-high magnetic field strengths benefits from a dramatic increase in contrast to noise ratio, we hypothesized that it could monitor anesthesia effects on brain blood oxygenation. We scanned rat brains at 7T and 17.2T under general anesthesia using different anesthetics (isoflurane, ketamine-xylazine, medetomidine. We showed that the brain/vessels contrast in T(2*-weighted images at 17.2T varied directly according to the applied pharmacological anesthetic agent, a phenomenon that was visible, but to a much smaller extent at 7T. This variation is in agreement with the mechanism of action of these agents. These data demonstrate that preclinical ultra-high field MRI can monitor the effects of a given drug on brain blood oxygenation level in the absence of systemic blood oxygenation changes and of any neural stimulation.

  11. Electrochemical Separation, Pumping, and Storage of Hydrogen or Oxygen into Nanocapillaries Via High Pressure MEA Seals

    Science.gov (United States)

    2015-10-13

    412TW-PA-15560 Electrochemical Separation, Pumping, and Storage of Hydrogen or Oxygen into Nanocapillaries Via High Pressure MEA Seals...TITLE AND SUBTITLE Electrochemical Separation, Pumping, and Storage of Hydrogen or Oxygen into Nanocapillaries Via High Pressure MEA Seals...density storage of gases remains a major technological hurdle for many fields. The U.S. Department of Energy (DOE), for example, reduced their hydrogen

  12. Preservation of high glycolytic phenotype by establishing new acute lymphoblastic leukemia cell lines at physiologic oxygen concentration

    Energy Technology Data Exchange (ETDEWEB)

    Sheard, Michael A., E-mail: msheard@chla.usc.edu [Developmental Therapeutics Program, USC-CHLA Institute for Pediatric Clinical Research, Division of Hematology-Oncology, Children' s Hospital Los Angeles, 4650 Sunset Blvd., Los Angeles, CA 90027 (United States); Ghent, Matthew V., E-mail: mattghent@gmail.com [Department of Pathology, Keck School of Medicine, University of Southern California, Health Sciences Campus, Los Angeles, CA 90089 (United States); Cabral, Daniel J., E-mail: dcabral14@gmail.com [Cancer Center and Departments of Cell Biology & Biochemistry, Pharmacology & Neuroscience, Internal Medicine and Pediatrics, School of Medicine, Texas Tech University Health Sciences Center, Lubbock, TX 79430 (United States); Lee, Joanne C., E-mail: joannebarnhart@gmail.com [Cancer Center and Departments of Cell Biology & Biochemistry, Pharmacology & Neuroscience, Internal Medicine and Pediatrics, School of Medicine, Texas Tech University Health Sciences Center, Lubbock, TX 79430 (United States); Khankaldyyan, Vazgen, E-mail: khangaldian@yahoo.com [Developmental Therapeutics Program, USC-CHLA Institute for Pediatric Clinical Research, Division of Hematology-Oncology, Children' s Hospital Los Angeles, 4650 Sunset Blvd., Los Angeles, CA 90027 (United States); Ji, Lingyun, E-mail: lingyun.ji@med.usc.edu [Developmental Therapeutics Program, USC-CHLA Institute for Pediatric Clinical Research, Division of Hematology-Oncology, Children' s Hospital Los Angeles, 4650 Sunset Blvd., Los Angeles, CA 90027 (United States); Wu, Samuel Q., E-mail: swu@chla.usc.edu [Medical Genetics, Children' s Hospital Los Angeles, 4650 Sunset Blvd., Los Angeles, CA 90027 (United States); Kang, Min H., E-mail: min.kang@ttuhsc.edu [Cancer Center and Departments of Cell Biology & Biochemistry, Pharmacology & Neuroscience, Internal Medicine and Pediatrics, School of Medicine, Texas Tech University Health Sciences Center, Lubbock, TX 79430 (United States); and others

    2015-05-15

    Cancer cells typically exhibit increased glycolysis and decreased mitochondrial oxidative phosphorylation, and they continue to exhibit some elevation in glycolysis even under aerobic conditions. However, it is unclear whether cancer cell lines employ a high level of glycolysis comparable to that of the original cancers from which they were derived, even if their culture conditions are changed to physiologically relevant oxygen concentrations. From three childhood acute lymphoblastic leukemia (ALL) patients we established three new pairs of cell lines in both atmospheric (20%) and physiologic (bone marrow level, 5%) oxygen concentrations. Cell lines established in 20% oxygen exhibited lower proliferation, survival, expression of glycolysis genes, glucose consumption, and lactate production. Interestingly, the effects of oxygen concentration used during cell line initiation were only partially reversible when established cell cultures were switched from one oxygen concentration to another for eight weeks. These observations indicate that ALL cell lines established at atmospheric oxygen concentration can exhibit relatively low levels of glycolysis and these levels are semi-permanent, suggesting that physiologic oxygen concentrations may be needed from the time of cell line initiation to preserve the high level of glycolysis commonly exhibited by leukemias in vivo. - Highlights: • Establishing new ALL cell lines in 5% oxygen resulted in higher glycolytic expression and function. • Establishing new ALL cell lines in 5% oxygen resulted in higher proliferation and lower cell death. • The divergent metabolic phenotypes selected in 5% and 20% oxygen are semi-permanent.

  13. Preservation of high glycolytic phenotype by establishing new acute lymphoblastic leukemia cell lines at physiologic oxygen concentration

    International Nuclear Information System (INIS)

    Sheard, Michael A.; Ghent, Matthew V.; Cabral, Daniel J.; Lee, Joanne C.; Khankaldyyan, Vazgen; Ji, Lingyun; Wu, Samuel Q.; Kang, Min H.

    2015-01-01

    Cancer cells typically exhibit increased glycolysis and decreased mitochondrial oxidative phosphorylation, and they continue to exhibit some elevation in glycolysis even under aerobic conditions. However, it is unclear whether cancer cell lines employ a high level of glycolysis comparable to that of the original cancers from which they were derived, even if their culture conditions are changed to physiologically relevant oxygen concentrations. From three childhood acute lymphoblastic leukemia (ALL) patients we established three new pairs of cell lines in both atmospheric (20%) and physiologic (bone marrow level, 5%) oxygen concentrations. Cell lines established in 20% oxygen exhibited lower proliferation, survival, expression of glycolysis genes, glucose consumption, and lactate production. Interestingly, the effects of oxygen concentration used during cell line initiation were only partially reversible when established cell cultures were switched from one oxygen concentration to another for eight weeks. These observations indicate that ALL cell lines established at atmospheric oxygen concentration can exhibit relatively low levels of glycolysis and these levels are semi-permanent, suggesting that physiologic oxygen concentrations may be needed from the time of cell line initiation to preserve the high level of glycolysis commonly exhibited by leukemias in vivo. - Highlights: • Establishing new ALL cell lines in 5% oxygen resulted in higher glycolytic expression and function. • Establishing new ALL cell lines in 5% oxygen resulted in higher proliferation and lower cell death. • The divergent metabolic phenotypes selected in 5% and 20% oxygen are semi-permanent

  14. Muscle tissue oxygenation, pressure, electrical, and mechanical responses during dynamic and static voluntary contractions

    DEFF Research Database (Denmark)

    Vedsted, Pernille; Blangsted, Anne Katrine; Søgaard, Karen

    2006-01-01

    tension (rTO(2)) would be larger during dynamic (DYN) than intermittent static (IST) low force contractions; and that (2) oxygen tension would remain lower in the resting periods subsequent to DYN as compared to those following IST. Eight subjects performed elbow flexions with identical time......-tension products: (1) DYN as a 20 degrees elbow movement of 2 s concentric and 2 s eccentric followed by a 4 s rest; and (2) IST with a 4 s contraction followed by a 4 s rest. Each session was performed for 1 min at 10 and 20% of the maximal voluntary contraction (MVC). The force, bipolar surface EMG, MMG, IMP, rTO......, respectively), and a similar picture was seen for the eccentric phase. However, no differences were seen in rTO(2) in either the contraction or the rest periods. In a prolonged rest period (8 s) after the sessions, DYN but not IST showed rTO(2) above baseline level. In conclusion, rTO(2) in DYN and IST were...

  15. Cerebral oxygenation and metabolism during exercise following three months of endurance training in healthy overweight males

    DEFF Research Database (Denmark)

    Seifert, T; Rasmussen, P; Brassard, P

    2009-01-01

    /(glucose + (1/2) lactate); OCI], changes in mitochondrial oxygen tension (DeltaP(Mito)O(2)) and the cerebral metabolic rate of oxygen (CMRO(2)) were calculated. For all subjects, resting OCI was higher at the 3-mo follow-up (6.3 +/- 1.3 compared with 4.7 +/- 0.9 at baseline, mean +/- SD; P ... with a lower plasma epinephrine concentration (P Mito)O(2) (-22 mmHg) decreased (P ... +/- 53 micromol x 100 x g(-1) min(-1) (P Mito)O(2) (-7 +/- 13 mmHg) did not decrease significantly from rest and when compared with values before training (P

  16. Parachute Cord Tension Sensor

    Data.gov (United States)

    National Aeronautics and Space Administration — To design and fabricate a light weight (few oz), very small (~2 inch length) parachute cord tension sensor demonstrator device.A major challenge for the CPAS (The...

  17. Composite resin reinforced with pre-tensioned fibers: a three-dimensional finite element study on stress distribution.

    Science.gov (United States)

    Jie, Lin; Shinya, Akikazu; Lassila, Lippo V J; Vallittu, Pekka K

    2013-01-01

    Pre-tensioned construction material is utilized in engineering applications of high strength demands. The purpose of this study was to evaluate the effect of the pre-tensioning fibers of fiber-reinforced composite (FRC) using three-dimensional finite element (FE) analysis. The 3D FE models of particulate composite resin (CR), FRC and composite resin reinforced with pre-tensioned fibers (PRE-T-FRC) were constructed. The uniaxial three-point bending test was simulated using FE analysis to calculate the principal stress distribution. In the FRC and PRE-T-FRC, stresses were higher than CR, and they were located in the fiber. However, the maximum principal stress value at the composite of PRE-T-FRC was lower than the FRC and CR. Composite resin reinforced with pre-tensioned fibers was advantageous for stress distribution and lowering the stress at the composite itself. Experimental studies on physical properties of pre-tensioned FRC are encouraged to be conducted.

  18. Tension-filled Governance?

    DEFF Research Database (Denmark)

    Celik, Tim Holst

    on the statesituated tension-filled functional relationship between legitimation and accumulation, the study both historically and theoretically reworks this approach and reapplies it for the post-1970s/1990s governance period. It asks whether and to what extent governance has served as a distinctive post- 1970s/1990s...

  19. Focal adhesions, stress fibers and mechanical tension

    Energy Technology Data Exchange (ETDEWEB)

    Burridge, Keith, E-mail: Keith_Burridge@med.unc.edu [Department of Cell Biology and Physiology, and Lineberger Comprehensive Cancer Center, 12-016 Lineberger, CB#7295, University of North Carolina, Chapel Hill, NC (United States); Guilluy, Christophe, E-mail: christophe.guilluy@univ-nantes.fr [Inserm UMR-S1087, CNRS UMR-C6291, L' institut du Thorax, and Université de Nantes, Nantes (France)

    2016-04-10

    Stress fibers and focal adhesions are complex protein arrays that produce, transmit and sense mechanical tension. Evidence accumulated over many years led to the conclusion that mechanical tension generated within stress fibers contributes to the assembly of both stress fibers themselves and their associated focal adhesions. However, several lines of evidence have recently been presented against this model. Here we discuss the evidence for and against the role of mechanical tension in driving the assembly of these structures. We also consider how their assembly is influenced by the rigidity of the substratum to which cells are adhering. Finally, we discuss the recently identified connections between stress fibers and the nucleus, and the roles that these may play, both in cell migration and regulating nuclear function. - Highlights: • The different types of stress fiber and focal adhesion are described. • We discuss the controversy about tension and assembly of these structures. • We describe the different models used to investigate assembly of these structures. • The influence of substratum rigidity is discussed. • Stress fiber connections to the nucleus are reviewed.

  20. Simultaneous measurement of surface tension and viscosity using freely decaying oscillations of acoustically levitated droplets

    Science.gov (United States)

    Kremer, J.; Kilzer, A.; Petermann, M.

    2018-01-01

    Oscillations of small liquid drops around a spherical shape have been of great interest to scientists measuring physical properties such as interfacial tension and viscosity, over the last few decades. A powerful tool for contactless positioning is acoustic levitation, which has been used to simultaneously determine the surface tension and viscosity of liquids at ambient pressure. In order to extend this acoustic levitation measurement method to high pressure systems, the method is first evaluated under ambient pressure. To measure surface tension and viscosity using acoustically levitated oscillating drops, an image analysis method has to be developed and factors which may affect measurement, such as sound field or oscillation amplitude, have to be analyzed. In this paper, we describe the simultaneous measurement of surface tension and viscosity using freely decaying shape oscillations of acoustically levitated droplets of different liquids (silicone oils AK 5 and AK 10, squalane, 1-propanol, 1-butanol, 1-pentanol, 1-hexanol, 1-heptanol, and 1-octanol) in air. These liquids vary in viscosity from 2 to about 30 mPa s. An acoustic levitation system, including an optimized standing wave acoustic levitator and a high-speed camera, was used for this study. An image analysis was performed with a self-written Matlab® code. The frequency of oscillation and the damping constant, required for the determination of surface tension and viscosity, respectively, were calculated from the evolution of the equatorial and polar radii. The results and observations are compared to data from the literature in order to analyze the accuracy of surface tension and viscosity determination, as well as the effect of non-spherical drop shape or amplitude of oscillation on measurement.

  1. Preservation of high glycolytic phenotype by establishing new acute lymphoblastic leukemia cell lines at physiologic oxygen concentration.

    Science.gov (United States)

    Sheard, Michael A; Ghent, Matthew V; Cabral, Daniel J; Lee, Joanne C; Khankaldyyan, Vazgen; Ji, Lingyun; Wu, Samuel Q; Kang, Min H; Sposto, Richard; Asgharzadeh, Shahab; Reynolds, C Patrick

    2015-05-15

    Cancer cells typically exhibit increased glycolysis and decreased mitochondrial oxidative phosphorylation, and they continue to exhibit some elevation in glycolysis even under aerobic conditions. However, it is unclear whether cancer cell lines employ a high level of glycolysis comparable to that of the original cancers from which they were derived, even if their culture conditions are changed to physiologically relevant oxygen concentrations. From three childhood acute lymphoblastic leukemia (ALL) patients we established three new pairs of cell lines in both atmospheric (20%) and physiologic (bone marrow level, 5%) oxygen concentrations. Cell lines established in 20% oxygen exhibited lower proliferation, survival, expression of glycolysis genes, glucose consumption, and lactate production. Interestingly, the effects of oxygen concentration used during cell line initiation were only partially reversible when established cell cultures were switched from one oxygen concentration to another for eight weeks. These observations indicate that ALL cell lines established at atmospheric oxygen concentration can exhibit relatively low levels of glycolysis and these levels are semi-permanent, suggesting that physiologic oxygen concentrations may be needed from the time of cell line initiation to preserve the high level of glycolysis commonly exhibited by leukemias in vivo. Copyright © 2015. Published by Elsevier Inc.

  2. Influence on cervical MR imaging by tension. Comparison between the picture quality of cervical MR image and tension

    International Nuclear Information System (INIS)

    Iseki, Tadahiro; Okano, Tamotsu; Kanou, Norio; Tanaka, Kazuharu; Kawasaki, Kouichi; Kawachi, Toshiaki

    2003-01-01

    In our first report, we compared influence on cervical MR image (C-MRI) by fear and anxiety on between the first time and experienced patients, in which the significant difference was not seen between those patients. Then, the present study, we made a comparison of the picture sharpness of C-MRI on between patients who were in states of tension and not, and on among tense patients by several causes. Our study showed the tendency which the good quality pictures were easy to be obtained in the experienced patients who were tensely and the poor quality pictures were in the patients who were not, which could not demonstrated the statistical significant difference. However, as compared the respective cause which induces tension with the picture sharpness, the patients with tenses caused by MR device showed to be difficult to be obtained the good quality pictures. The present study suggested that ''unsuitable tension'', which was overstrung due to fear and anxiety from MR device, was difficult to obtain good quality picture of C-MRI, and that ''suitable tension'', with which could be kept still during the examination, was easy to do it. (author)

  3. Tensions between Teams and Their Leaders

    Directory of Open Access Journals (Sweden)

    J. David Johnson

    2016-10-01

    Full Text Available The intersection of teamwork and leadership results in tensions, dilemmas, and paradoxes for both individuals and for institutions such as simultaneously empowering individuals at the same time it frustrates them when our naive, cultural understanding of leadership centralizes power and values leaders who can impose their will and vision on others. Perhaps the fundamental paradox of teamwork and leadership is that the more leadership is focused on an individual the less likely a team’s potential will be realized. Six specific domains where tensions arise are: at team boundaries; culture; who is in charge, rationality/cognition; diversity; and collaborations. Three approaches - clarifying different levels of analysis, temporal factors, and overarching concepts - to resolving tensions are discussed. New conceptions of leadership and the importance of the larger cultural frame within which they are embedded are needed for the management of technology and innovation.

  4. Effect of supplementing a high-fat, low-carbohydrate enteral formula in COPD patients.

    Science.gov (United States)

    Cai, Baiqiang; Zhu, Yuanjue; Ma, Y i; Xu, Zuojun; Zao, Y i; Wang, Jinglan; Lin, Yaoguang; Comer, Gail M

    2003-03-01

    One of the goals in treating patients with chronic obstructive pulmonary disease (COPD) who suffer from hypoxemia, hypercapnia, and malnutrition is to correct the malnutrition without increasing the respiratory quotient and minimize the production of carbon dioxide. This 3-wk study evaluated the efficacy of feeding a high-fat, low-carbohydrate (CHO) nutritional supplement as opposed to a high-carbohydrate diet in COPD patients on parameters of pulmonary function.S METHODS: Sixty COPD patients with low body weight (diet (15% protein, 20% to 30% fat, and 60% to 70% CHO), or the experimental group, which received two to three cans (237 mL/can) of a high-fat, low-CHO oral supplement (16.7% protein, 55.1% fat, and 28.2% CHO) in the evening as part of the diet. Measurements of lung function (forced expiratory volume in 1 s or volume of air exhaled in 1 s of maximal expiration, minute ventilation, oxygen consumption per unit time, carbon dioxide production in unit time, and respiratory quotient) and blood gases (pH, arterial carbon dioxide tension, and arterial oxygen tension) were taken at baseline and after 3 wk. Lung function measurements decreased significantly and forced expiratory volume increased significantly in the experimental group. This study demonstrates that pulmonary function in COPD patients can be significantly improved with a high-fat, low-CHO oral supplement as compared with the traditional high-CHO diet.

  5. Rearfoot eversion has indirect effects on plantar fascia tension by changing the amount of arch collapse.

    Science.gov (United States)

    Lee, Sae Yong; Hertel, Jay; Lee, Sung Cheol

    2010-01-01

    Rearfoot eversion motion and arch height are believed to contribute to increased tension on the plantar fascia and arch collapse during gait but the specifics of these relationships are not clear. To examine the relationships among static arch height, rearfoot eversion, dynamic arch height, and plantar fascia tension. 28 healthy males participated. After static arch height was measured, the subjects were asked to run at 4.5m/s while frontal plane rearfoot motion, dynamic arch height, and ground reaction forces were collected. The relationships among variables were examined with bivariate correlations and path analysis. The results indicated a high correlation between dynamic arch height and static arch height (r=0.642), plantar fascia tension (r=-0.797), and maximum rearfoot eversion motion during gait (r=-0.518). The path analysis model without the direct rearfoot eversion effect explained 81.2% of the variance in plantar fascia tension, while the model with the direct rearfoot eversion effect explained 82.1% of the variance in plantar fascia tension. Including the indirect effect of maximum rearfoot eversion motion on plantar fascia tension through control of dynamic arch height is the model that best explains the interrelationships of these foot characteristics. The amount of maximum rearfoot eversion motion itself is not a good predictor of plantar fascia tension, however, together with the arch height, maximum rearfoot eversion motion is a good predictor because it has a pronounced indirect effect on plantar fascia tension. Copyright 2010. Published by Elsevier Ltd.

  6. Bending Under Tension Test with Direct Friction Measurement

    DEFF Research Database (Denmark)

    Andreasen, Jan Lasson; Olsson, David Dam; Chodnikiewicz, K.

    2004-01-01

    A special BUT-transducer has been developed in which friction around the tool radius can be directly measured when drawing a plane sheet strip around a cylindrical tool-pin under constant back tension. The front tension, back tension and torque on the tool-pin are all measured directly, thus...... enabling accurate measurement of friction and direct determination of lubricant film breakdown for varying normal pressure, sliding speed, tool radius and tool preheat temperature. The transducer is applied in an experimental investigation focusing on limits of lubrication in drawing of stainless steel...

  7. Oxygen-Partial-Pressure Sensor for Aircraft Oxygen Mask

    Science.gov (United States)

    Kelly, Mark; Pettit, Donald

    2003-01-01

    A device that generates an alarm when the partial pressure of oxygen decreases to less than a preset level has been developed to help prevent hypoxia in a pilot or other crewmember of a military or other high-performance aircraft. Loss of oxygen partial pressure can be caused by poor fit of the mask or failure of a hose or other component of an oxygen distribution system. The deleterious physical and mental effects of hypoxia cause the loss of a military aircraft and crew every few years. The device is installed in the crewmember s oxygen mask and is powered via communication wiring already present in all such oxygen masks. The device (see figure) includes an electrochemical sensor, the output potential of which is proportional to the partial pressure of oxygen. The output of the sensor is amplified and fed to the input of a comparator circuit. A reference potential that corresponds to the amplified sensor output at the alarm oxygen-partial-pressure level is fed to the second input of the comparator. When the sensed partial pressure of oxygen falls below the minimum acceptable level, the output of the comparator goes from the low state (a few millivolts) to the high state (near the supply potential, which is typically 6.8 V for microphone power). The switching of the comparator output to the high state triggers a tactile alarm in the form of a vibration in the mask, generated by a small 1.3-Vdc pager motor spinning an eccentric mass at a rate between 8,000 and 10,000 rpm. The sensation of the mask vibrating against the crewmember s nose is very effective at alerting the crewmember, who may already be groggy from hypoxia and is immersed in an environment that is saturated with visual cues and sounds. Indeed, the sensation is one of rudeness, but such rudeness could be what is needed to stimulate the crewmember to take corrective action in a life-threatening situation.

  8. Treating tension-type headache -- an expert opinion

    DEFF Research Database (Denmark)

    Bendtsen, Lars; Jensen, Rigmor

    2011-01-01

    INTRODUCTION: Tension-type headache (TTH) is a highly prevalent disorder with enormous costs for the individual and the society. AREAS COVERED: Nonpharmacological and pharmacological treatments are reviewed. Electromyographic (EMG) biofeedback has a documented effect in TTH, while cognitive-behav...... and clarify how treatment programs can be optimized and combined to best suit the individual patient. Frequent TTH may be difficult to treat, but an acceptable result can usually be obtained by a combination of nonpharmacological and pharmacological treatments....

  9. Simultaneous administration of glucose and hyperoxic gas achieves greater improvement in tumor oxygenation than hyperoxic gas alone

    International Nuclear Information System (INIS)

    Snyder, Stacey A.; Lanzen, Jennifer L.; Braun, Rod D.; Rosner, Gary; Secomb, Timothy W.; Biaglow, John; Brizel, David M.; Dewhirst, Mark W.

    2001-01-01

    Purpose: To test the feasibility of hyperglycemic reduction of oxygen consumption combined with oxygen breathing (O 2 ), to improve tumor oxygenation. Methods and Materials: Fischer-344 rats bearing 1 cm R3230Ac flank tumors were anesthetized with Nembutal. Mean arterial pressure, heart rate, tumor blood flow ([TBF], laser Doppler flowmetry), pH, and pO 2 were measured before, during, and after glucose (1 or 4 g/kg) and/or O 2 . Results: Mean arterial pressure and heart rate were unaffected by treatment. Glucose at 1 g/kg yielded maximum blood glucose of 400 mg/dL, no change in TBF, reduced tumor pH (0.17 unit), and 3 mm Hg pO 2 rise. Glucose at 4 g/kg yielded maximum blood glucose of 900 mg/dL, pH drop of 0.6 unit, no pO 2 change, and reduced TBF (31%). Oxygen tension increased by 5 mm Hg with O 2 . Glucose (1 g/Kg) + O 2 yielded the largest change in pO 2 (27 mm Hg); this is highly significant relative to baseline or either treatment alone. The effect was positively correlated with baseline pO 2 , but 6 of 7 experiments with baseline pO 2 2 to improve tumor oxygenation. However, some cell lines are not susceptible to the Crabtree effect, and the magnitude is dependent on baseline pO 2 . Additional or alternative manipulations may be necessary to achieve more uniform improvement in pO 2

  10. NOx emissions from high swirl turbulent spray flames with highly oxygenated fuels

    KAUST Repository

    Bohon, Myles; Roberts, William L.

    2013-01-01

    Combustion of fuels with fuel bound oxygen is of interest from both a practical and a fundamental viewpoint. While a great deal of work has been done studying the effect of oxygenated additives in diesel and gasoline engines, much less has been done

  11. Determination of oxygen content in high T/sub c/ superconductors by a charged particle activation method

    International Nuclear Information System (INIS)

    Tao, Z.; Alburger, D.E.; Jones, K.W.; Yao, Y.D.; Kao, Y.H.

    1988-01-01

    A new method for determining the oxygen content in high T/sub c/ superconductors has been demonstrated using a charged particle activation technique. This method allows a measurement of the concentration of 16 O atoms in the superconducting material by detection of the 17 F produced with the 16 O(d,n) 17 F nuclear reaction. By way of example, this technique is applied to the determination of oxygen content in a series of high T/sub c/ Y-Ba-Cu-O samples in which the stoichiometry is varied by reducing the copper concentration. The stabilized oxygen content shows a nonlinear dependence on the copper deficiency in these specimens

  12. Electron attachment to oxygen, ozone and other compounds of atmospheric relevance as studied with ultra-high energy resolution

    International Nuclear Information System (INIS)

    Maerk, T.D.; Matejcik, S.; Kiendler, A.; Cicman, P.; Senn, G.; Skalny, J.; Stampfli, P.; Illenberger, E.; Chu, Y.; Stamatovic, A.

    1996-01-01

    The processes of electron attachment to oxygen, ozone, ozone/oxygen cluster and oxygen cluster as well as other compounds of atmospheric relevance (CF 2 Cl 2 , CHCl 3 and CCl 3 Br) were studied with ultra-high energy resolution crossed beam technique

  13. Corrosion resistance of grouted post-tensioning systems : [summary].

    Science.gov (United States)

    2013-08-01

    The increased popularity of post-tensioned bridge construction in the United States has led to concerns about corrosion and its impact on the life cycle of these bridges. Although the vast majority of post-tensioned bridges in the United States have ...

  14. Boerhaave's syndrome and tension pneumothorax secondary to Norovirus induced forceful emesis

    DEFF Research Database (Denmark)

    Venø, Søren; Eckardt, Jens

    2013-01-01

    Boerhaave's syndrome or spontaneous esophageal perforation is a rare condition, with high mortality. We describe a case of Boerhaave's syndrome presenting with tension pneumothorax. The patient was infected with Norovirus and developed Boerhaave's syndrome, initially thought to be gastroenteritis...

  15. Artificial intelligence tools to support the analysis of the high tension insulator flaming; Herramientas de inteligencia artificial de apoyo al analisis de flameos en aisladores de alta tension

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Ortiz, Guillermo; Mejia Lavalle, Manuel; Montoya Tena, Gerardo [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    Four artificial intelligence tools developed at the Instituto de Investigaciones Electricas (IIE) to support the analysis of high tension insulator flaming are described. The first tool builds up a decision tree departing from historical data, the other 3 tools operate departing from the decision tree previously created to generate production rules, function as an expert system and make tests with many already known cases. These tools could predict the impending occurrence of flaming with enough time allowance for the insulators to be cleaned, since the traditional practice is the periodical cleaning of the insulators and this is not always adequate since the cleaning teams are limited, and the action of the environment is not always constant and for that reason insulators that do not need it are cleaned and vice-versa [Espanol] Se describen 4 herramientas de inteligencia artificial desarrolladas en el Instituto de Investigaciones Electricas (IIE) para apoyar al analisis de flameos en aisladores de alta tension. La primera herramienta construye el arbol de decision a partir de datos historicos; las otras 3 herramientas operan a partir del arbol de decision previamente creado para generar reglas de produccion, funcionar a la manera de un sistema experto y hacer pruebas con muchos casos conocidos. Estas herramientas podrian predecir la ocurrencia inminente del flameo con tiempo suficiente para que los aisladores se limpien, ya que la forma tradicional es limpiar periodicamente los aisladores y esto a veces no es adecuado debido a que las cuadrillas de limpieza son limitadas, ademas de que la accion del medio ambiente no es constante y es por eso que a veces se limpian aisladores que no lo necesitan o viceversa

  16. Artificial intelligence tools to support the analysis of the high tension insulator flaming; Herramientas de inteligencia artificial de apoyo al analisis de flameos en aisladores de alta tension

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Ortiz, Guillermo; Mejia Lavalle, Manuel; Montoya Tena, Gerardo [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    Four artificial intelligence tools developed at the Instituto de Investigaciones Electricas (IIE) to support the analysis of high tension insulator flaming are described. The first tool builds up a decision tree departing from historical data, the other 3 tools operate departing from the decision tree previously created to generate production rules, function as an expert system and make tests with many already known cases. These tools could predict the impending occurrence of flaming with enough time allowance for the insulators to be cleaned, since the traditional practice is the periodical cleaning of the insulators and this is not always adequate since the cleaning teams are limited, and the action of the environment is not always constant and for that reason insulators that do not need it are cleaned and vice-versa [Espanol] Se describen 4 herramientas de inteligencia artificial desarrolladas en el Instituto de Investigaciones Electricas (IIE) para apoyar al analisis de flameos en aisladores de alta tension. La primera herramienta construye el arbol de decision a partir de datos historicos; las otras 3 herramientas operan a partir del arbol de decision previamente creado para generar reglas de produccion, funcionar a la manera de un sistema experto y hacer pruebas con muchos casos conocidos. Estas herramientas podrian predecir la ocurrencia inminente del flameo con tiempo suficiente para que los aisladores se limpien, ya que la forma tradicional es limpiar periodicamente los aisladores y esto a veces no es adecuado debido a que las cuadrillas de limpieza son limitadas, ademas de que la accion del medio ambiente no es constante y es por eso que a veces se limpian aisladores que no lo necesitan o viceversa

  17. Three-dimensional finite element modelling of the uniaxial tension test

    DEFF Research Database (Denmark)

    Østergaard, Lennart; Stang, Henrik

    2002-01-01

    . One of the most direct methods for determination of the σ-w relationship is the uniaxial tension test, where a notched specimen is pulled apart while the tensile load and the crack opening displacement is observed. This method is appealing since the interpretation is straightforward. The method......Experimental determination of the stress-crack opening relationship (σ-w) for concrete as defined in the fictitious crack model has proven to be difficult. This is due to the problems that may arise from application of the inverse analysis method necessary for the derivation of the relationship...... is examined in this paper through three dimensional finite element analyses. It is concluded that the interpretation of the uniaxial tension test is indeed straightforward, if the testing machine stiffness is sufficiently high....

  18. Oxygen pathway modeling estimates high reactive oxygen species production above the highest permanent human habitation.

    Directory of Open Access Journals (Sweden)

    Isaac Cano

    Full Text Available The production of reactive oxygen species (ROS from the inner mitochondrial membrane is one of many fundamental processes governing the balance between health and disease. It is well known that ROS are necessary signaling molecules in gene expression, yet when expressed at high levels, ROS may cause oxidative stress and cell damage. Both hypoxia and hyperoxia may alter ROS production by changing mitochondrial Po2 (PmO2. Because PmO2 depends on the balance between O2 transport and utilization, we formulated an integrative mathematical model of O2 transport and utilization in skeletal muscle to predict conditions to cause abnormally high ROS generation. Simulations using data from healthy subjects during maximal exercise at sea level reveal little mitochondrial ROS production. However, altitude triggers high mitochondrial ROS production in muscle regions with high metabolic capacity but limited O2 delivery. This altitude roughly coincides with the highest location of permanent human habitation. Above 25,000 ft., more than 90% of exercising muscle is predicted to produce abnormally high levels of ROS, corresponding to the "death zone" in mountaineering.

  19. Evaluation of Repair Tension in Arthroscopic Rotator Cuff Repair: Does It Really Matter to the Integrity of the Rotator Cuff?

    Science.gov (United States)

    Kim, Do Hoon; Jang, Young Hoon; Choi, Young Eun; Lee, Hwa-Ryeong; Kim, Sae Hoon

    2016-11-01

    Repair tension of a torn rotator cuff can affect healing after repair. However, a measurement of the actual tension during arthroscopic rotator cuff repair is not feasible. The relationship between repair tension and healing of a rotator cuff repair remains unclear. The purpose of this study was to evaluate the effect of repair tension on healing at the repair site. The hypothesis was that repair tension would be a major factor in determining the anatomic outcome of rotator cuff repair. Cohort study; Level of evidence, 2. Arthroscopic rotator cuff repairs (132 patients) for full-thickness rotator cuff tears were analyzed. An intraoperative model was designed for the estimation of repair tension using a tensiometer. Magnetic resonance imaging (MRI) was performed approximately 1 year (mean [±SD], 12.7 ± 3.2 months) postoperatively for the evaluation of healing at the repair site. Multivariable analysis was performed for tear size, amount of retraction, and fatty degeneration (FD) of rotator cuff muscles. The mean repair tension measured during the arthroscopic procedure was 28.5 ± 23.1 N. There was a statistically significant correlation between tension and tear size (Pearson correlation coefficient [PCC], 0.529; P repair tension also showed a significant inverse correlation with healing at the repair site (SCC, 0.195; P = .025). However, when sex, age, tear size, amount of retraction, tendon quality, and FD of rotator cuff muscles were included for multivariable logistic regression analysis, only FD of the infraspinatus showed an association with the anatomic outcome of repair (Exp(B) = 0.596; P = .010). Our intraoperative model for the estimation of rotator cuff repair tension showed an inverse correlation of repair tension with healing at the repair site, suggesting that complete healing is less likely with high-tension repairs. A significant association was observed on MRI between a high level of FD of the infraspinatus and repaired tendon integrity. © 2016

  20. Oxygen-Rich Lithium Oxide Phases Formed at High Pressure for Potential Lithium-Air Battery Electrode.

    Science.gov (United States)

    Yang, Wenge; Kim, Duck Young; Yang, Liuxiang; Li, Nana; Tang, Lingyun; Amine, Khalil; Mao, Ho-Kwang

    2017-09-01

    The lithium-air battery has great potential of achieving specific energy density comparable to that of gasoline. Several lithium oxide phases involved in the charge-discharge process greatly affect the overall performance of lithium-air batteries. One of the key issues is linked to the environmental oxygen-rich conditions during battery cycling. Here, the theoretical prediction and experimental confirmation of new stable oxygen-rich lithium oxides under high pressure conditions are reported. Three new high pressure oxide phases that form at high temperature and pressure are identified: Li 2 O 3 , LiO 2 , and LiO 4 . The LiO 2 and LiO 4 consist of a lithium layer sandwiched by an oxygen ring structure inherited from high pressure ε-O 8 phase, while Li 2 O 3 inherits the local arrangements from ambient LiO 2 and Li 2 O 2 phases. These novel lithium oxides beyond the ambient Li 2 O, Li 2 O 2 , and LiO 2 phases show great potential in improving battery design and performance in large battery applications under extreme conditions.

  1. Gene expression profiles in relation to tension and dissociation in borderline personality disorder.

    Directory of Open Access Journals (Sweden)

    Christian Schmahl

    Full Text Available The biological underpinnings of borderline personality disorder (BPD and its psychopathology including states of aversive tension and dissociation is poorly understood. Our goal was to examine transcriptional changes associated with states of tension or dissociation within individual patients in a pilot study. Dissociation is not only a critical symptom of BPD but has also been associated with higher risk for self-mutilation and depression. We conducted a whole blood gene expression profile analysis using quantitative PCR in 31 female inpatients with BPD. For each individual, two samples were drawn during a state of high tension and dissociation, while two samples were drawn at non-tension states. There was no association between gene expression and tension states. However, we could show that Interleukin-6 was positively correlated to dissociation scores, whereas Guanine nucleotide-binding protein G(s subunit alpha isoforms, Mitogen-activated protein kinase 3 and 8, Guanine nucleotide-binding protein G(i subunit alpha-2, Beta-arrestin-1 and 2, and Cyclic AMP-responsive element-binding protein were negatively correlated to dissociation. Our data point to a potential association of dissociation levels with the expression of genes involved in immune system regulation as well as cellular signalling/second-messenger systems. Major limitations of the study are the the possibly heterogeneous cell proportions in whole blood and the heterogeneous medication.

  2. Burning of forest materials under late Paleozoic high atmospheric oxygen levels

    Science.gov (United States)

    Richard A., Jr. Wildman; Leo J. Hickey; Matthew B. Dickinson; Robert A. Berner; Jennifer M. Robinson; Michael Dietrich; Robert H. Essenhigh; Craig B. Wildman

    2004-01-01

    Theoretical models suggest that atmospheric oxygen reached concentrations as high as 35% O2 during the past 550 m.y. Previous burning experiments using strips of paper have challenged this idea, concluding that ancient wildfires would have decimated plant life if O2 significantly exceeded its present level of 21%. New...

  3. Low-Flammability PTFE for High-Oxygen Environments

    Science.gov (United States)

    Walle, E.; Fallon, B.; Sheppard, A.

    1986-01-01

    Modified forming process removes volatile combustible materials. Flammability of cable-wrapping tape reduced by altering tape-manufacturing process. In new manufacturing process, tape formed by proprietary process of screw extrusion, followed by washing in solvent and drying. Tape then wrapped as before. Spectrogram taken after extrusion, washing, and drying shows lower hydrocarbon content. PTFE formed by new process suited to oxygen-rich environments. Safe in liquid oxygen of Space Shuttle tank and in medical uses; thin-wall shrinkable tubing in hospital test equipment, surgical instruments, and implants.

  4. Kinetics of the high temperature oxygen exchange reaction on 238PuO2 powder

    International Nuclear Information System (INIS)

    Whiting, Christofer E.; Du, Miting; Felker, L. Kevin; Wham, Robert M.; Barklay, Chadwick D.; Kramer, Daniel P.

    2015-01-01

    Oxygen exchange reactions performed on PuO 2 suggest the reaction is influenced by at least three mechanisms: an internal chemical reaction, surface mobility of active species/defects, and surface exchange of gaseous oxygen with lattice oxygen. Activation energies for the surface mobility and internal chemical reaction are presented. Determining which mechanism is dominant appears to be a complex function including at least specific surface area and temperature. Thermal exposure may also impact the oxygen exchange reaction by causing reductions in the specific surface area of PuO 2 . Previous CeO 2 surrogate studies exhibit similar behavior, confirming that CeO 2 is a good qualitative surrogate for PuO 2 , in regards to the oxygen exchange reaction. Comparison of results presented here with previous work on the PuO 2 oxygen exchange reaction allows complexities in the previous work to be explained. These explanations allowed new conclusions to be drawn, many of which confirm the conclusions presented here. - Highlights: • PuO 2 Oxygen exchange kinetics can be influenced by at least 3 different mechanisms. • An internal chemical reaction controls the rate at high temperature and large SSA. • Surface mobility and surface exchange influence rate at lower temperatures and SSA. • Exchange temperatures may alter SSA and make data difficult to interpret.

  5. Quantification of oxygen and carbon in high Tc superconducting films by (α,α) elastic resonance technique

    International Nuclear Information System (INIS)

    Vizkelethy, G.; Revesz, P.

    1993-01-01

    The quantification of oxygen and carbon in high-temperature (T c ) superconducting oxide thin films was made by employing elastic resonance in He backscattering analysis. A method combining the oxygen resonance technique and channeling was presented for measuring the nature of the oxygen disorder near the surface and the interface in a YBCO superconducting film grown on an MgO substrate. The oxygen resonance technique was used to quantify the oxygen profiling in the metal/YBCO contacts, showing that Zr and Nb act as sinks to oxygen from YBCO films and are oxidized in the forms Zr/ZrO 2 /YBCO/MgO and Nb 0.2 O/YBCO/MgO after annealing in a vacuum at 350 o C. We combined the carbon and oxygen resonances to determine the carbon contamination and oxygen concentration changes on the YBCO surface after coating and baking the photoresist. Residual carbon on the surface and a thin layer of oxygen depletion near the YBCO surface have been observed. The residual carbon in Bi 2 Sr 2 CaCu 2 O 8 films made by the decomposition of metallo-organic precursors was quantified using carbon resonance. (author)

  6. Inclusion and Participation: Working with the Tensions

    Directory of Open Access Journals (Sweden)

    Gideon Calder

    2011-12-01

    Full Text Available Democracy is crucially about inclusion: a theory of democracy must account for who is to be included in the democratic process, how, and on what terms. Inclusion, if conceived democratically, is fraught with tensions. This article identifies three such tensions, arising respectively in: (i the inauguration of the democratic public; (ii enabling equal participation; and (iii the relationship between instrumental and non-instrumental accounts of democracy’s value. In each case, I argue, rather than seeking somehow to dissolve or avoid such tensions, theories of democracy should allow us to live with their implications reflexively: to work with them. Such tensions are counter-democratic to the extent that they derail what Nancy Fraser calls “participatory parity,” under which citizens count as “full partners in social interaction.” But the extent to which they do this is not itself dependent on points of paradox in the very idea of inclusion. Such parity relies on complex factors, social and economic, which democratic institutions and procedures will not by themselves address. To achieve full democratic inclusion we must already have addressed such factors; no account of democracy itself, however finely-tuned, will do this.

  7. Solubility of oxygen in a seawater medium in equilibrium with a high-pressure oxy-helium atmosphere.

    Science.gov (United States)

    Taylor, C D

    1979-06-01

    The molar oxygen concentration in a seawater medium in equilibrium with a high-pressure oxygen-helium atmosphere was measured directly in pressurized subsamples, using a modified version of the Winkler oxygen analysis. At a partial pressure of oxygen of 1 atm or less, its concentration in the aqueous phase was adequately described by Henry's Law at total pressures up to 600 atm. This phenomenon, which permits a straightforward determination of dissolved oxygen within hyperbaric systems, resulted from pressure-induced compensatory alterations in the Henry's Law variables rather than from a true obedience to the Ideal Gas Law. If the partial pressure of a gas contributes significantly to the hydrostatic pressure, Henry's Law is no longer adequate for determining its solubility within the compressed medium.

  8. A multislice single breath-hold scheme for imaging alveolar oxygen tension in humans.

    Science.gov (United States)

    Hamedani, Hooman; Kadlecek, Stephen J; Emami, Kiarash; Kuzma, Nicholas N; Xu, Yinan; Xin, Yi; Mongkolwisetwara, Puttisarn; Rajaei, Jennia; Barulic, Amy; Wilson Miller, G; Rossman, Milton; Ishii, Masaru; Rizi, Rahim R

    2012-05-01

    Reliable, noninvasive, and high-resolution imaging of alveolar partial pressure of oxygen (p(A)O(2)) is a potentially valuable tool in the early diagnosis of pulmonary diseases. Several techniques have been proposed for regional measurement of p(A)O(2) based on the increased depolarization rate of hyperpolarized (3) He. In this study, we explore one such technique by applying a multislice p(A)O(2) -imaging scheme that uses interleaved-slice ordering to utilize interslice time-delays more efficiently. This approach addresses the low spatial resolution and long breath-hold requirements of earlier techniques, allowing p(A)O(2) measurements to be made over the entire human lung in 10-15 s with a typical resolution of 8.3 × 8.3 × 15.6 mm(3). PO(2) measurements in a glass syringe phantom were in agreement with independent gas analysis within 4.7 ± 4.1% (R = 0.9993). The technique is demonstrated in four human subjects (healthy nonsmoker, healthy former smoker, healthy smoker, and patient with COPD), each imaged six times on 3 different days during a 2-week span. Two independent measurements were performed in each session, consisting of 12 coronal slices. The overall p(A)O(2) mean across all subjects was 95.9 ± 12.2 Torr and correlated well with end-tidal O(2) (R = 0.805, P < 0.0001). The alveolar O(2) uptake rate was consistent with the expected range of 1-2 Torr/s. Repeatable visual features were observed in p(A)O(2) maps over different days, as were characteristic differences among the subjects and gravity-dependent effects. Copyright © 2011 Wiley Periodicals, Inc.

  9. Study of high energy ion implantation of boron and oxygen in silicon

    International Nuclear Information System (INIS)

    Thevenin, P.

    1991-06-01

    Three aspects of high energy (0.5-3 MeV) light ions ( 11 B + and 16 O + ) implantation in silicon are examined: (1)Spatial repartition; (2) Target damage and (3) Synthesis by oxygen implantation of a buried silicon oxide layer

  10. 33 CFR 147.809 - Mars Tension Leg Platform safety zone.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Mars Tension Leg Platform safety... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.809 Mars Tension Leg Platform safety zone. (a) Description. The Mars Tension Leg Platform (Mars TLP) is located at position 28°10′10.29...

  11. Clinical evidence on high flow oxygen therapy and active humidification in adults.

    Science.gov (United States)

    Gotera, C; Díaz Lobato, S; Pinto, T; Winck, J C

    2013-01-01

    Recently there has been growing interest in an alternative to conventional oxygen therapy: the heated, humidified high flow nasal cannula oxygen therapy (HFNC). A number of physiological effects have been described with HFNC: pharyngeal dead space washout, reduction of nasopharyngeal resistance, a positive expiratory pressure effect, an alveolar recruitment, greater humidification, more comfort and better tolerance by the patient, better control of FiO2 and mucociliary clearance. There is limited experience of HFNC in adults. There are no established guidelines or decision-making pathways to guide use of the HFNC therapy for adults. In this article we review the existing evidence of HFNC oxygen therapy in adult patients, its advantages, limitations and the current literature on clinical applications. Further research is required to determine the long-term effect of this therapy and identify the adult patient population to whom it is most beneficial. Copyright © 2013 Sociedade Portuguesa de Pneumologia. Published by Elsevier España. All rights reserved.

  12. Material Usage in High Pressure Oxygen Systems for the International Space Station

    Science.gov (United States)

    Kravchenko, Michael; Sievers, D. Elliott

    2014-01-01

    The Nitrogen/Oxygen Recharge System (NORS) for the International Space Station (ISS) Program was required as part of the Space Shuttle retirement efforts to sustain the ISS life support systems. The system is designed around a 7000 psia Oxygen or Nitrogen Recharge Tank Assembly which is able to be utilized both internally and externally to the ISS. Material selection and usage were critical to ensure oxygen compatibility for the design, while taking into consideration toxicity, weldability, brazability and general fabrication and assembly techniques. The system uses unique hardware items such a composite overwrap pressure vessel (COPV), high pressure mechanical gauges, compact regulators and valves, quick disconnects, metal tubing and flexhoses. Numerous challenges and anomalies were encountered due to the exotic nature of this project which will be discussed in detail. The knowledge gained from these anomalies and failure resolutions can be applied to more than space applications, but can also be applicable to industry pressurized systems.

  13. Tension bulla: a cause of reversible pulmonary hypertension.

    Science.gov (United States)

    Waxman, Michael J; Waxman, Jacob D; Forman, John M

    2015-01-01

    A tension pneumothorax represents a medical emergency warranting urgent diagnosis and treatment. A rapidly expanding bulla may resemble the same clinical presentation but requires an entirely different treatment. A 53-year-old woman presented with increasing shortness of breath and her physical examination and chest x-ray were interpreted as showing a tension pneumothorax. A chest tube was placed which did not resolve the process. Placement of a second chest tube was likewise unsuccessful. A chest CT was then performed and was interpreted as showing an unresolved tension pneumothorax, despite seemingly adequate placement of the 2 chest tubes. Further review of the CT showed the border of a giant bulla and a tentative diagnosis was made of a rapidly expanding bulla with tension physiology. Echocardiogram revealed significant pulmonary hypertension. The bulla was surgically excised, the patient had marked improvement in her clinical symptoms and signs, and echocardiographic follow-up showed complete resolution of the pulmonary hypertension.

  14. Leadership. Using Creative Tension.

    Science.gov (United States)

    Cook, David L.

    1986-01-01

    Leadership involves maintaining a balance of the variables which comprise leadership. Love and fear, types of power, success and effectiveness, and driving and restraining forces are discussed as sources of the creative tension a leader uses to influence others. (MT)

  15. Mimicking physiological O2 tension in the female reproductive tract improves Assisted Reproduction outcomes in pig.

    Science.gov (United States)

    García-Martínez, S; Sánchez-Hurtado, M A; Gutiérrez, H; Sánchez-Margallo, F M; Romar, R; Latorre, R; Coy, P; López-Albors, O

    2018-02-27

    48hpi, cleavage was evaluated under the stereomicroscope. Finally, at 180hpi, development to the blastocyst stage was quantified, blastocyst morphology was assessed, and embryos were fixed and stained to count the mean cell number per blastocyst. The mean O2 content within the pig oviduct and uterus was always lower than in ambient air. The average O2 percentage was higher in gilts (10.0%) than in sows (7.6%) (p number of cells in embryos cultured under the low O2 concentration (88.9 ± 5.9) was observed compared to those cultured under 20% O2 (59.0 ± 5.0) (p < 0.05). None. Although minimally invasive surgery was used the effect of anaesthesia and manipulations on O2 tension within the organs are unknown. Using physiological oxygen concentrations in IVF/EC could improve ART outcomes. This study was funded by Spanish Ministry of Economy and Competitiveness (MINECO) and European Regional Development Fund (FEDER). Grants AGL2012-40180-C03-01 and AGL2015-66341-R. The authors declare no conflict of interest.

  16. Surface tension of H2O and D2O

    International Nuclear Information System (INIS)

    Vargaftik, N.B.; Voljak, L.D.; Volkov, B.N.

    1975-01-01

    There is a great number of works on surface tension of clean water (H 2 O) at temperatures up to 100 deg C and very few above the boiling point. Works on surface tension of heavy water (D 2 O) are insufficient. A review of works on surface tension of both kinds of water is given

  17. Children’s Oxygen Administration Strategies Trial (COAST:  A randomised controlled trial of high flow versus oxygen versus control in African children with severe pneumonia [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Kathryn Maitland

    2018-01-01

    Full Text Available Background: In Africa, the clinical syndrome of pneumonia remains the leading cause of morbidity and mortality in children in the post-neonatal period. This represents a significant burden on in-patient services. The targeted use of oxygen and simple, non-invasive methods of respiratory support may be a highly cost-effective means of improving outcome, but the optimal oxygen saturation threshold that results in benefit and the best strategy for delivery are yet to be tested in adequately powered randomised controlled trials. There is, however, an accumulating literature about the harms of oxygen therapy across a range of acute and emergency situations that have stimulated a number of trials investigating permissive hypoxia. Methods: In 4200 African children, aged 2 months to 12 years, presenting to 5 hospitals in East Africa with respiratory distress and hypoxia (oxygen saturation or = 80% (permissive hypoxia; and High flow using AIrVO2TM compared with low flow delivery (routine care. Discussion: The overarching objective is to address the key research gaps in the therapeutic use of oxygen in resource-limited setting in order to provide a better evidence base for future management guidelines. The trial has been designed to address the poor outcomes of children in sub-Saharan Africa, which are associated with high rates of in-hospital mortality, 9-10% (for those with oxygen saturations of 80-92% and 26-30% case fatality for those with oxygen saturations <80%. Clinical trial registration: ISRCTN15622505 Trial status: Recruiting

  18. A wireless smart sensor network for automated monitoring of cable tension

    International Nuclear Information System (INIS)

    Sim, Sung-Han; Cho, Soojin; Li, Jian; Jo, Hongki; Park, Jong-Woong; Jung, Hyung-Jo; Spencer Jr, Billie F

    2014-01-01

    As cables are primary load carrying members in cable-stayed bridges, monitoring the tension forces of the cables provides valuable information regarding structural soundness. Incorporating wireless smart sensors with vibration-based tension estimation methods provides an efficient means of autonomous long-term monitoring of cable tensions. This study develops a wireless cable tension monitoring system using MEMSIC’s Imote2 smart sensors. The monitoring system features autonomous operation, sustainable energy harvesting and power consumption, and remote access using the internet. To obtain the tension force, an in-network data processing strategy associated with the vibration-based tension estimation method is implemented on the Imote2-based sensor network, significantly reducing the wireless data transmission and the power consumption. The proposed monitoring system has been deployed and validated on the Jindo Bridge, a cable-stayed bridge located in South Korea. (paper)

  19. A wireless smart sensor network for automated monitoring of cable tension

    Science.gov (United States)

    Sim, Sung-Han; Li, Jian; Jo, Hongki; Park, Jong-Woong; Cho, Soojin; Spencer, Billie F., Jr.; Jung, Hyung-Jo

    2014-02-01

    As cables are primary load carrying members in cable-stayed bridges, monitoring the tension forces of the cables provides valuable information regarding structural soundness. Incorporating wireless smart sensors with vibration-based tension estimation methods provides an efficient means of autonomous long-term monitoring of cable tensions. This study develops a wireless cable tension monitoring system using MEMSIC’s Imote2 smart sensors. The monitoring system features autonomous operation, sustainable energy harvesting and power consumption, and remote access using the internet. To obtain the tension force, an in-network data processing strategy associated with the vibration-based tension estimation method is implemented on the Imote2-based sensor network, significantly reducing the wireless data transmission and the power consumption. The proposed monitoring system has been deployed and validated on the Jindo Bridge, a cable-stayed bridge located in South Korea.

  20. Kinetic therapy improves oxygenation in critically ill pediatric patients.

    Science.gov (United States)

    Schultz, Theresa Ryan; Lin, Richard; Francis, Barbara A; Hales, Roberta L; Colborn, Shawn; Napoli, Linda A; Helfaer, Mark A

    2005-07-01

    To compare changes in oxygenation after manual turning and percussion (standard therapy) and after automated rotation and percussion (kinetic therapy). Randomized crossover trial. General and cardiac pediatric intensive care units. Intubated and mechanically ventilated pediatric patients who had an arterial catheter and no contraindications to using a PediDyne bed. Patients were placed on a PediDyne bed (Kinetic Concepts) and received 18 hrs blocks of standard and kinetic therapy in an order determined by randomization. Arterial blood gases were measured every 2 hrs during each phase of therapy. Oxygenation index and arterial-alveolar oxygen tension difference [P(A-a)O(2)] were calculated. Indexes calculated at baseline and after each 18-hr phase of therapy were analyzed. Fifty patients were enrolled. Data from 15 patients were either not collected or not used due to reasons that included violation of protocol and inability to tolerate the therapies in the study. Indexes of oxygenation were not normally distributed and were compared using Wilcoxon signed rank testing. Both therapies led to improvements in oxygenation, but only those from kinetic therapy achieved statistical significance. In patients receiving kinetic therapy first, median oxygenation index decreased from 7.4 to 6.19 (p = .015). The median P(A-a)O(2) decreased from 165.2 to 126.4 (p = .023). There were continued improvements in oxygenation after the subsequent period of standard therapy, with the median oxygenation index decreasing to 5.52 and median P(A-a)O(2) decreasing to 116.0, but these changes were not significant (p = .365 and .121, respectively). When standard therapy was first, the median oxygenation index decreased from 8.83 to 8.71 and the median P(a-a)o(2) decreased from 195.4 to 186.6. Neither change was significant. Median oxygenation index after the subsequent period of kinetic therapy was significantly lower (7.91, p = .044) and median P(A-a)O(2) trended lower (143.4, p = .077