WorldWideScience

Sample records for high inter-tester reliability

  1. High inter-tester reliability of the new mobility score in patients with hip fracture

    DEFF Research Database (Denmark)

    Kristensen, M.T.; Bandholm, T.; Foss, N.B.

    2008-01-01

    OBJECTIVE: To assess the inter-tester reliability of the New Mobility Score in patients with acute hip fracture. DESIGN: An inter-tester reliability study. SUBJECTS: Forty-eight consecutive patients with acute hip fracture at a median age of 84 (interquartile range, 76-89) years; 40 admitted from...

  2. High inter-tester reliability of the new mobility score in patients with hip fracture

    DEFF Research Database (Denmark)

    Kristensen, M.T.; Bandholm, T.; Foss, N.B.

    2008-01-01

    OBJECTIVE: To assess the inter-tester reliability of the New Mobility Score in patients with acute hip fracture. DESIGN: An inter-tester reliability study. SUBJECTS: Forty-eight consecutive patients with acute hip fracture at a median age of 84 (interquartile range, 76-89) years; 40 admitted from...... their own home and 8 from nursing homes to an acute orthopaedic hip fracture unit at a university hospital. METHODS: The New Mobility Score, which evaluates the prefracture functional level with a score from 0 (not able to walk at all) to 9 (fully independent), was assessed by 2 independent physiotherapists...... the prefracture functional level in patients with acute hip fracture Udgivelsesdato: 2008/7...

  3. Inter-tester reliability of selected clinical tests for long-lasting temporomandibular disorders.

    Science.gov (United States)

    Julsvoll, Elisabeth Heggem; Vøllestad, Nina Køpke; Opseth, Gro; Robinson, Hilde Stendal

    2017-09-01

    Clinical tests used to examine patients with temporomandibular disorders vary in methodological quality, and some are not tested for reliability. The purpose of this cross-sectional study was to evaluate inter-tester reliability of clinical tests and a cluster of tests used to examine patients with long-lasting temporomandibular disorders. Forty patients with pain in the temporomandibular area treated by health-professionals were included. They were between 18-70 years, had 65 symptomatic (33 right/32 left) and 15 asymptomatic joints. Two manual therapists examined all participants with selected tests. Percentage agreement and the kappa coefficient ( k ) with 95% confidence interval (CI) were used to evaluate the tests with categorical outcomes. For tests with continuous outcomes, the relative inter-tester reliability was assessed by the intraclass-correlation-coefficient (ICC 3,1 , 95% CI) and the absolute reliability was calculated by the smallest detectable change (SDC). The best reliability among single tests was found for the dental stick test, the joint-sound test ( k  = 0.80-1.0) and range of mouth-opening (ICC 3,1 (95% CI) = 0.97 (0.95-0.98) and SDC = 4 mm). The reliability of cluster of tests was excellent with both four and five positive tests out of seven. The reliability was good to excellent for the clinical tests and the cluster of tests when performed by experienced therapists. The tests are feasible for use in the clinical setting. They require no advanced equipment and are easy to perform.

  4. Reliability of knee joint range of motion and circumference measurements after total knee arthroplasty: does tester experience matter?

    DEFF Research Database (Denmark)

    Jakobsen, Thomas Linding; Christensen, Malene; Christensen, Stine Sommer

    2010-01-01

    : The design was an intra-tester, inter-tester and intra-day reliability study. Nineteen outpatients (10 females) having received a TKA were examined by an inexperienced and an experienced physiotherapist. Following a standardized protocol, active and passive knee joint ROM and circumference measurements were...

  5. Two ankle joint laxity testers: reliability and validity

    NARCIS (Netherlands)

    Kerkhoffs, Gino M. M. J.; Blankevoort, Leendert; Sierevelt, Inger N.; Corvelein, Ruby; Janssen, Guido H. W.; van Dijk, C. Niek

    2005-01-01

    Two test devices were manufactured to objectively measure ankle joint laxity: the dynamic anterior ankle tester (DAAT) and the quasi-static anterior ankle tester (QAAT). The primary aim was to analyse the reliability of both testers; The secondary aim was to assess validity in correlation with TELOS

  6. Reliability of externally fixed dynamometry hamstring strength testing in elite youth football players.

    Science.gov (United States)

    Wollin, Martin; Purdam, Craig; Drew, Michael K

    2016-01-01

    To investigate inter and intra-tester reliability of an externally fixed dynamometry unilateral hamstring strength test, in the elite sports setting. Reliability study. Sixteen, injury-free, elite male youth football players (age=16.81±0.54 years, height=180.22±5.29cm, weight 73.88±6.54kg, BMI=22.57±1.42) gave written informed consent. Unilateral maximum isometric peak hamstring force was evaluated by externally fixed dynamometry for inter-tester, intra-day and intra-tester, inter-week reliability. The test position was standardised to correlate with the terminal swing phase of the gait running cycle. Inter and intra-tester values demonstrated good to high levels of reliability. The intra-class coefficient (ICC) for inter-tester, intra-day reliability was 0.87 (95% CI=0.75-0.93) with standard error of measure percentage (SEM%) 4.7 and minimal detectable change percentage (MDC%) 12.9. Intra-tester, inter-week reliability results were ICC 0.86 (95% CI, 0.74-0.93), SEM% 5.0 and MDC% 14.0. This study demonstrates good to high inter and intra-tester reliability of isometric externally fixed dynamometry unilateral hamstring strength testing in the regular elite sport setting involving elite male youth football players. The intra-class coefficient in association with the low standard error of measure and minimal detectable change percentages suggest that this procedure is appropriate for clinical and academic use as well as monitoring hamstring strength in the elite sport setting. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  7. The reliability of knee joint position testing using electrogoniometry

    Directory of Open Access Journals (Sweden)

    Winter Adele

    2008-01-01

    Full Text Available Abstract Background The current investigation examined the inter- and intra-tester reliability of knee joint angle measurements using a flexible Penny and Giles Biometric® electrogoniometer. The clinical utility of electrogoniometry was also addressed. Methods The first study examined the inter- and intra-tester reliability of measurements of knee joint angles in supine, sitting and standing in 35 healthy adults. The second study evaluated inter-tester and intra-tester reliability of knee joint angle measurements in standing and after walking 10 metres in 20 healthy adults, using an enhanced measurement protocol with a more detailed electrogoniometer attachment procedure. Both inter-tester reliability studies involved two testers. Results In the first study, inter-tester reliability (ICC[2,10] ranged from 0.58–0.71 in supine, 0.68–0.79 in sitting and 0.57–0.80 in standing. The standard error of measurement between testers was less than 3.55° and the limits of agreement ranged from -12.51° to 12.21°. Reliability coefficients for intra-tester reliability (ICC[3,10] ranged from 0.75–0.76 in supine, 0.86–0.87 in sitting and 0.87–0.88 in standing. The standard error of measurement for repeated measures by the same tester was less than 1.7° and the limits of agreement ranged from -8.13° to 7.90°. The second study showed that using a more detailed electrogoniometer attachment protocol reduced the error of measurement between testers to 0.5°. Conclusion Using a standardised protocol, reliable measures of knee joint angles can be gained in standing, supine and sitting by using a flexible goniometer.

  8. A reliability study of the new sensors for movement analysis (SHARIF-HMIS).

    Science.gov (United States)

    Abedi, Mohen; Manshadi, Farideh Dehghan; Zavieh, Minoo Khalkhali; Ashouri, Sajad; Azimi, Hadi; Parnanpour, Mohamad

    2016-04-01

    SHARIF-HMIS is a new inertial sensor designed for movement analysis. The aim of the present study was to assess the inter-tester and intra-tester reliability of some kinematic parameters in different lumbar motions making use of this sensor. 24 healthy persons and 28 patients with low back pain participated in the current reliability study. The test was performed in five different lumbar motions consisting of lumbar flexion in 0, 15, and 30° in the right and left directions. For measuring inter-tester reliability, all the tests were carried out twice on the same day separately by two physiotherapists. Intra-tester reliability was assessed by reproducing the tests after 3 days by the same physiotherapist. The present study revealed satisfactory inter- and intra-tester reliability indices in different positions. ICCs for intra-tester reliability ranged from 0.65 to 0.98 and 0.59 to 0.81 for healthy and patient participants, respectively. Also, ICCs for inter-tester reliability ranged from 0.65 to 0.92 for the healthy and 0.65 to 0.87 for patient participants. In general, it can be inferred from the results that measuring the kinematic parameters in lumbar movements using inertial sensors enjoys acceptable reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Test-retest reliability of myofascial trigger point detection in hip and thigh areas.

    Science.gov (United States)

    Rozenfeld, E; Finestone, A S; Moran, U; Damri, E; Kalichman, L

    2017-10-01

    Myofascial trigger points (MTrP's) are a primary source of pain in patients with musculoskeletal disorders. Nevertheless, they are frequently underdiagnosed. Reliable MTrP palpation is the necessary for their diagnosis and treatment. The few studies that have looked for intra-tester reliability of MTrPs detection in upper body, provide preliminary evidence that MTrP palpation is reliable. Reliability tests for MTrP palpation on the lower limb have not yet been performed. To evaluate inter- and intra-tester reliability of MTrP recognition in hip and thigh muscles. Reliability study. 21 patients (15 males and 6 females, mean age 21.1 years) referred to the physical therapy clinic, 10 with knee or hip pain and 11 with pain in an upper limb, low back, shin or ankle. Two experienced physical therapists performed the examinations, blinded to the subjects' identity, medical condition and results of the previous MTrP evaluation. Each subject was evaluated four times, twice by each examiner in a random order. Dichotomous findings included a palpable taut band, tenderness, referred pain, and relevance of referred pain to patient's complaint. Based on these, diagnosis of latent MTrP's or active MTrP's was established. The evaluation was performed on both legs and included a total of 16 locations in the following muscles: rectus femoris (proximal), vastus medialis (middle and distal), vastus lateralis (middle and distal) and gluteus medius (anterior, posterior and distal). Inter- and intra-tester reliability (Cohen's kappa (κ)) values for single sites ranged from -0.25 to 0.77. Median intra-tester reliability was 0.45 and 0.46 for latent and active MTrP's, and median inter-tester reliability was 0.51 and 0.64 for latent and active MTrPs, respectively. The examination of the distal vastus medialis was most reliable for latent and active MTrP's (intra-tester k = 0.27-0.77, inter-tester k = 0.77 and intra-tester k = 0.53-0.72, inter-tester k = 0.72, correspondingly

  10. The validity and intra-tester reliability of markerless motion capture to analyse kinematics of the BMX Supercross gate start.

    Science.gov (United States)

    Grigg, Josephine; Haakonssen, Eric; Rathbone, Evelyne; Orr, Robin; Keogh, Justin W L

    2017-11-13

    The aim of this study was to quantify the validity and intra-tester reliability of a novel method of kinematic measurement. The measurement target was the joint angles of an athlete performing a BMX Supercross (SX) gate start action through the first 1.2 s of movement in situ on a BMX SX ramp using a standard gate start procedure. The method employed GoPro® Hero 4 Silver (GoPro Inc., USA) cameras capturing data at 120 fps 720 p on a 'normal' lens setting. Kinovea 0.8.15 (Kinovea.org, France) was used for analysis. Tracking data was exported and angles computed in Matlab (Mathworks®, USA). The gold standard 3D method for joint angle measurement could not safely be employed in this environment, so a rigid angle was used. Validity was measured to be within 2°. Intra-tester reliability was measured by the same tester performing the analysis twice with an average of 55 days between analyses. Intra-tester reliability was high, with an absolute error <6° and <9 frames (0.075 s) across all angles and time points for key positions, respectively. The methodology is valid within 2° and reliable within 6° for the calculation of joint angles in the first ~1.25 s.

  11. The reliability of the newly developed bending tester for the measurement of flexural rigidity of textile materials

    Science.gov (United States)

    Haji Musa, A. Binti; Malengier, B.; Van Langenhove, L.; Stevens, C.

    2017-10-01

    A new automated bending tester was developed in Ghent University, Belgium to reduce the human interference in the bending measurement. This paper reports the investigations made on the tester in order to confirm the reliability of its measurement. For that, 11 types of fabrics with different construction parameters were tested for their bending length and flexural rigidity using the new bending tester and the results were compared with that of the standard or manual bending tester, which were conducted in accordance with BS 3356:1990 standard method. Statistical analysis confirms that both measurements are strongly correlated with Pearson’s R≥ 0.90 for all the measurements made. It means that the results from the new automated tester show good correlations with the standard measurement. Nevertheless, this prototype version of the new tester still needs to be adjusted to optimise the functionality of it and further investigations should be done to justify the robustness of the results.

  12. Inter-operator and inter-device agreement and reliability of the SEM Scanner.

    Science.gov (United States)

    Clendenin, Marta; Jaradeh, Kindah; Shamirian, Anasheh; Rhodes, Shannon L

    2015-02-01

    The SEM Scanner is a medical device designed for use by healthcare providers as part of pressure ulcer prevention programs. The objective of this study was to evaluate the inter-rater and inter-device agreement and reliability of the SEM Scanner. Thirty-one (31) volunteers free of pressure ulcers or broken skin at the sternum, sacrum, and heels were assessed with the SEM Scanner. Each of three operators utilized each of three devices to collect readings from four anatomical sites (sternum, sacrum, left and right heels) on each subject for a total of 108 readings per subject collected over approximately 30 min. For each combination of operator-device-anatomical site, three SEM readings were collected. Inter-operator and inter-device agreement and reliability were estimated. Over the course of this study, more than 3000 SEM Scanner readings were collected. Agreement between operators was good with mean differences ranging from -0.01 to 0.11. Inter-operator and inter-device reliability exceeded 0.80 at all anatomical sites assessed. The results of this study demonstrate the high reliability and good agreement of the SEM Scanner across different operators and different devices. Given the limitations of current methods to prevent and detect pressure ulcers, the SEM Scanner shows promise as an objective, reliable tool for assessing the presence or absence of pressure-induced tissue damage such as pressure ulcers. Copyright © 2015 Bruin Biometrics, LLC. Published by Elsevier Ltd.. All rights reserved.

  13. The development and application of portable speed tester for special equipment

    International Nuclear Information System (INIS)

    Lan Peng; Chen Ligang; Dai Sidan; Wang Huiting; Zhang Liangxu; Wang Lin

    2014-01-01

    Special equipment developed to meet the needs for research and industrial application of this stage, with the advantages of small size, high accuracy, long working hours, high reliability and intelligent portable speed tester. This paper describes the development and application of the tester. In terms of hardware, the tester use 'MCU + CPLD' to build the core of the system, and focus on high precision, low-power design, Software to increase their power electricity monitoring and filtering software anti-interference function. The tester can achieve high-precision measurement of the speed parameter, display measurement data in real time via the LCD display functions. Currently, the tester has been successfully achieved industrial application. (authors)

  14. Reliability of hand-held dynamometry for measurement of lower limb muscle strength in children with Duchenne and Becker muscular dystrophy

    Directory of Open Access Journals (Sweden)

    Wei SHI

    2015-05-01

    Full Text Available Objective To determine the reliability of hand-held dynamometry (HHD for lower limb isometric muscle strength measurement in children with Duchenne and Becker muscular dystrophy (DMD/BMD.  Methods A total of 21 children [20 males and one female; mean age was (7.88 ± 2.87 years, ranging between 3.96-14.09 years; mean age at diagnosis was (5.88 ± 2.88 years, ranging between 1.35-12.89 years; mean height was (120.64 ± 16.30 cm, ranging between 97-153 cm; mean body weight was (24.62 ± 9.05 kg, ranging between 14-50 kg] with DMD (19/21 and BMD (2/21 were involved from Rehabilitation Center of Children's Hospital of Fudan University. The muscle strength of hip, knee and ankle was measured by HHD under standardized test methods. The test-retest results were compared to determine the inter-test reliability, and the results among testers were compared to determine the inter-tester reliability.  Results HHD showed fine inter-tester reliability (ICC = 0.762-0.978 and inter-test reliability (ICC = 0.690-0.938 in measuring lower limb muscle strength of children with DMD/BMD. Results also showed relatively poor reliability in distal muscle groups (foot plantar flexion and dorsiflexion.  Conclusions HHD, showing fine inter-tester and inter-test reliability in measuring the lower limb muscle strength of children with DMD/BMD, can be used in monitoring muscle strength changing and assessing effects of clinical interventions. DOI: 10.3969/j.issn.1672-6731.2015.05.009

  15. The Berg Balance Scale has high intra- and inter-rater reliability but absolute reliability varies across the scale: a systematic review.

    Science.gov (United States)

    Downs, Stephen; Marquez, Jodie; Chiarelli, Pauline

    2013-06-01

    What is the intra-rater and inter-rater relative reliability of the Berg Balance Scale? What is the absolute reliability of the Berg Balance Scale? Does the absolute reliability of the Berg Balance Scale vary across the scale? Systematic review with meta-analysis of reliability studies. Any clinical population that has undergone assessment with the Berg Balance Scale. Relative intra-rater reliability, relative inter-rater reliability, and absolute reliability. Eleven studies involving 668 participants were included in the review. The relative intrarater reliability of the Berg Balance Scale was high, with a pooled estimate of 0.98 (95% CI 0.97 to 0.99). Relative inter-rater reliability was also high, with a pooled estimate of 0.97 (95% CI 0.96 to 0.98). A ceiling effect of the Berg Balance Scale was evident for some participants. In the analysis of absolute reliability, all of the relevant studies had an average score of 20 or above on the 0 to 56 point Berg Balance Scale. The absolute reliability across this part of the scale, as measured by the minimal detectable change with 95% confidence, varied between 2.8 points and 6.6 points. The Berg Balance Scale has a higher absolute reliability when close to 56 points due to the ceiling effect. We identified no data that estimated the absolute reliability of the Berg Balance Scale among participants with a mean score below 20 out of 56. The Berg Balance Scale has acceptable reliability, although it might not detect modest, clinically important changes in balance in individual subjects. The review was only able to comment on the absolute reliability of the Berg Balance Scale among people with moderately poor to normal balance. Copyright © 2013 Australian Physiotherapy Association. Published by .. All rights reserved.

  16. The navicular position test - a reliable measure of the navicular bone position during rest and loading

    DEFF Research Database (Denmark)

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard

    2011-01-01

    .08 degrees, ICC = 0.91. Discussion: The present data support The Navicular Position Test as a reliable test of the navicular bone position during rest and loading measured in a simple test set-up. Conclusion: The Navicular Position Test was shown to have a high intraday-, intra- and inter-tester reliability...

  17. Validity and reliability of a low-cost digital dynamometer for measuring isometric strength of lower limb.

    Science.gov (United States)

    Romero-Franco, Natalia; Jiménez-Reyes, Pedro; Montaño-Munuera, Juan A

    2017-11-01

    Lower limb isometric strength is a key parameter to monitor the training process or recognise muscle weakness and injury risk. However, valid and reliable methods to evaluate it often require high-cost tools. The aim of this study was to analyse the concurrent validity and reliability of a low-cost digital dynamometer for measuring isometric strength in lower limb. Eleven physically active and healthy participants performed maximal isometric strength for: flexion and extension of ankle, flexion and extension of knee, flexion, extension, adduction, abduction, internal and external rotation of hip. Data obtained by the digital dynamometer were compared with the isokinetic dynamometer to examine its concurrent validity. Data obtained by the digital dynamometer from 2 different evaluators and 2 different sessions were compared to examine its inter-rater and intra-rater reliability. Intra-class correlation (ICC) for validity was excellent in every movement (ICC > 0.9). Intra and inter-tester reliability was excellent for all the movements assessed (ICC > 0.75). The low-cost digital dynamometer demonstrated strong concurrent validity and excellent intra and inter-tester reliability for assessing isometric strength in the main lower limb movements.

  18. The reliability and validity of the Saliba Postural Classification System.

    Science.gov (United States)

    Collins, Cristiana Kahl; Johnson, Vicky Saliba; Godwin, Ellen M; Pappas, Evangelos

    2016-07-01

    To determine the reliability and validity of the Saliba Postural Classification System (SPCS). Two physical therapists classified pictures of 100 volunteer participants standing in their habitual posture for inter and intra-tester reliability. For validity, 54 participants stood on a force plate in a habitual and a corrected posture, while a vertical force was applied through the shoulders until the clinician felt a postural give. Data were extracted at the time the give was felt and at a time in the corrected posture that matched the peak vertical ground reaction force (VGRF) in the habitual posture. Inter-tester reliability demonstrated 75% agreement with a Kappa = 0.64 (95% CI = 0.524-0.756, SE = 0.059). Intra-tester reliability demonstrated 87% agreement with a Kappa = 0.8, (95% CI = 0.702-0.898, SE = 0.05) and 80% agreement with a Kappa = 0.706, (95% CI = 0.594-0818, SE = 0.057). The examiner applied a significantly higher (p < 0.001) peak vertical force in the corrected posture prior to a postural give when compared to the habitual posture. Within the corrected posture, the %VGRF was higher when the test was ongoing vs. when a postural give was felt (p < 0.001). The %VGRF was not different between the two postures when comparing the peaks (p = 0.214). The SPCS has substantial agreement for inter- and intra-tester reliability and is largely a valid postural classification system as determined by the larger vertical forces in the corrected postures. Further studies on the correlation between the SPCS and diagnostic classifications are indicated.

  19. Inter-Investigator Reliability of Anthropometric Prediction of 1RM Bench Press in College Football Players.

    Science.gov (United States)

    Schumacher, Richard M; Arabas, Jana L; Mayhew, Jerry L; Brechue, William F

    2016-01-01

    The purpose of this study was to determine the effect of inter-investigator differences in anthropometric assessments on the prediction of one-repetition maximum (1RM) bench press in college football players. Division-II players (n = 34, age = 20.4 ± 1.2 y, 182.3 ± 6.6 cm, 99.1 ± 18.4 kg) were measured for selected anthropometric variables and 1RM bench press at the conclusion of a heavy resistance training program. Triceps, subscapular, and abdominal skinfolds were measured in triplicate by three investigators and used to estimate %fat. Arm circumference was measured around a flexed biceps muscle and was corrected for triceps skinfold to estimate muscle cross-sectional area (CSA). Chest circumference was measured at mid-expiration. Significant differences among the testers were evident in six of the nine anthropometric variables, with the least experienced tester being significantly different from the other testers on seven variables, although average differences among investigators ranged from 1-2% for circumferences to 4-9% for skinfolds. The two more experienced testers were significantly different on only one variable. Overall agreement among testers was high (ICC>0.895) for each variable, with low coefficients of variation (CVbench press using a non-performance anthropometric equation. Minimal experience in anthropometry may not impede strength and conditioning specialists from accurately estimating 1RM bench press.

  20. Hip- and knee-strength assessments using a hand-held dynamometer with external belt-fixation are inter-tester reliable

    DEFF Research Database (Denmark)

    Thorborg, Kristian; Bandholm, Thomas; Hölmich, Per

    2013-01-01

    PURPOSE: In football, ice-hockey, and track and field, injuries have been predicted, and hip- and knee-strength deficits quantified using hand-held dynamometry (HHD). However, systematic bias exists when testers of different sex and strength perform the measurements. Belt-fixation of the dynamome...

  1. Reliability of movement control tests in the lumbar spine

    Directory of Open Access Journals (Sweden)

    de Bruin Eling D

    2007-09-01

    Full Text Available Abstract Background Movement control dysfunction [MCD] reduces active control of movements. Patients with MCD might form an important subgroup among patients with non specific low back pain. The diagnosis is based on the observation of active movements. Although widely used clinically, only a few studies have been performed to determine the test reliability. The aim of this study was to determine the inter- and intra-observer reliability of movement control dysfunction tests of the lumbar spine. Methods We videoed patients performing a standardized test battery consisting of 10 active movement tests for motor control in 27 patients with non specific low back pain and 13 patients with other diagnoses but without back pain. Four physiotherapists independently rated test performances as correct or incorrect per observation, blinded to all other patient information and to each other. The study was conducted in a private physiotherapy outpatient practice in Reinach, Switzerland. Kappa coefficients, percentage agreements and confidence intervals for inter- and intra-rater results were calculated. Results The kappa values for inter-tester reliability ranged between 0.24 – 0.71. Six tests out of ten showed a substantial reliability [k > 0.6]. Intra-tester reliability was between 0.51 – 0.96, all tests but one showed substantial reliability [k > 0.6]. Conclusion Physiotherapists were able to reliably rate most of the tests in this series of motor control tasks as being performed correctly or not, by viewing films of patients with and without back pain performing the task.

  2. Inter-Rater Reliability of Cyclotorsion Measurements Using Fundus Photography.

    Science.gov (United States)

    Dysli, Muriel; Kanku, Madeleine; Traber, Ghislaine L

    2018-04-01

    The foveo-papillary angle (FPA) on fundus photographs is the accepted standard for the measurement of ocular cyclotorsion. We assessed the inter-rater reliability of this method in healthy subjects and in patients with trochlear nerve palsies. In this methodological study, fundus photographs of healthy subjects and of patients with trochlear nerve palsies were made with a fundus camera (Zeiss Fundus Camera FF 450 plus, Jena, Germany). Three independent observers measured the FPA on the fundus photographs of all subjects in synedra View (synedra View 16, Version 16.0.0.11, Innsbruck, Austria). One hundred and four eyes of 52 subjects (26 healthy controls and 26 patients) were assessed. The mean FPA of the healthy controls was 5.80 degrees (°) [± 0.44 standard error of the mean (SEM)] compared to 11.55° (± 0.80 SEM) for patients with trochlear nerve palsies. The inter-rater reliability of all measured FPAs showed an intraclass correlation coefficient (ICC) of 0.98 (95% CI 0.97 - 0.98). The inter-rater reliability of objective cyclotorsion measurements using fundus photographs was very high. Georg Thieme Verlag KG Stuttgart · New York.

  3. Inter-rater and intra-rater reliability of the Bahasa Melayu version of Rose Angina Questionnaire.

    Science.gov (United States)

    Hassan, N B; Choudhury, S R; Naing, L; Conroy, R M; Rahman, A R A

    2007-01-01

    The objective of the study is to translate the Rose Questionnaire (RQ) into a Bahasa Melayu version and adapt it cross-culturally, and to measure its inter-rater and intrarater reliability. This cross sectional study was conducted in the respondents' homes or workplaces in Kelantan, Malaysia. One hundred respondents aged 30 and above with different socio-demographic status were interviewed for face validity. For each inter-rater and intra-rater reliability, a sample of 150 respondents was interviewed. Inter-rater and intra-rater reliabilities were assessed by Cohen's kappa. The overall inter-rater agreements by the five pair of interviewers at point one and two were 0.86, and intrarater reliability by the five interviewers on the seven-item questionnaire at poinone and two was 0.88, as measured by kappa coefficient. The translated Malay version of RQ demonstrated an almost perfect inter-rater and intra-rater reliability and further validation such as sensitivity and specificity analysis of this translated questionnaire is highly recommended.

  4. Validity and Reliability of a Digital Inclinometer to Assess Knee Joint Position Sense in an Open Kinetic Chain.

    Science.gov (United States)

    Romero-Franco, Natalia; Montaño-Munuera, Juan Antonio; Fernández-Domínguez, Juan Carlos; Jiménez-Reyes, Pedro

    2017-12-18

    New methods are being validated to easily evaluate the knee joint position sense (JPS) due to its role in sports movement and the risk of injury. However, no studies to date have considered the open kinetic chain (OKC) technique, despite the biomechanical differences compared to closed kinetic chain movements. To analyze the validity and reliability of a digital inclinometer to measure the knee JPS in the OKC movement. The validity, inter-tester and intra-tester reliability of a digital inclinometer for measuring knee JPS were evaluated. Sports research laboratory. Eighteen athletes (11 males and 7 females; 28.4 ± 6.6 years; 71.9 ± 14.0 kg; 1.77 ± 0.09 m; 22.8 ± 3.2 kg/m 2 ) voluntary participated in this study. Absolute angular error (AAE), relative angular error (RAE) and variable angular error (VAE) of knee JPS in an OKC. Intraclass correlation coefficient (ICC) and standard error of the mean (SEM) were calculated to determine the validity and reliability of the inclinometer. Data showed excellent validity of the inclinometer to obtain proprioceptive errors compared to the video analysis in JPS tasks (AAE: ICC = 0.981, SEM = 0.08; RAE: ICC = 0.974, SEM = 0.12; VAE: ICC = 0.973, SEM = 0.07). Inter-tester reliability was also excellent for all the proprioceptive errors (AAE: ICC = 0.967, SEM = 0.04; RAE: ICC = 0.974, SEM = 0.03; VAE: ICC = 0.939, SEM = 0.08). Similar results were obtained for intra-tester reliability (AAE: ICC = 0.861, SEM = 0.1; RAE: ICC = 0.894, SEM = 0.1; VAE: ICC = 0.700, SEM = 0.2). The digital inclinometer is a valid and reliable method to assess the knee JPS in OKC. Sport professionals may evaluate the knee JPS to monitor its deterioration during training or improvements throughout the rehabilitation process.

  5. Introducing a new definition of a near fall: intra-rater and inter-rater reliability.

    Science.gov (United States)

    Maidan, I; Freedman, T; Tzemah, R; Giladi, N; Mirelman, A; Hausdorff, J M

    2014-01-01

    Near falls (NFs) are more frequent than falls, and may occur before falls, potentially predicting fall risk. As such, identification of a NF is important. We aimed to assess intra and inter-rater reliability of the traditional definition of a NF and to demonstrate the potential utility of a new definition. To this end, 10 older adults, 10 idiopathic elderly fallers, and 10 patients with Parkinson's disease (PD) walked in an obstacle course while wearing a safety harness. All walks were videotaped. Forty-nine video segments were extracted to create 2 clips each of 8.48 min. Four raters scored each event using the traditional definition and, two weeks later, using the new definition. A fifth rater used only the new definition. Intra-rater reliability was determined using Kappa (K) statistics and inter-rater reliability was determined using ICC. Using the traditional definition, three raters had poor intra-rater reliability (K0.137) and one rater had moderate intra-rater reliability (K=0.624, pdefinition, inter-rater reliability between the four raters was moderate (ICC=0.667, pdefinition showed high intra-rater (K>0.601, pdefinition of NF is required. The results of the present study suggest that the proposed new definition increases intra and inter-rater reliability, a critical step for using NFs to quantify fall risk. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Inter- and intra-observer reliability of masking in plantar pressure measurement analysis.

    Science.gov (United States)

    Deschamps, K; Birch, I; Mc Innes, J; Desloovere, K; Matricali, G A

    2009-10-01

    Plantar pressure measurement is an important tool in gait analysis. Manual placement of small masks (masking) is increasingly used to calculate plantar pressure characteristics. Little is known concerning the reliability of manual masking. The aim of this study was to determine the reliability of masking on 2D plantar pressure footprints, in a population with forefoot deformity (i.e. hallux valgus). Using a random repeated-measure design, four observers identified the third metatarsal head on a peak-pressure barefoot footprint, using a small mask. Subsequently, the location of all five metatarsal heads was identified, using the same size of masks and the same protocol. The 2D positional variation of the masks and the peak pressure (PP) and pressure time integral (PTI) values of each mask were calculated. For single-masking the lowest inter-observer reliability was found for the distal-proximal direction, causing a clear, adverse impact on the reliability of the pressure characteristics (PP and PTI). In the medial-lateral direction the inter-observer reliability could be scored as high. Intra-observer reliability was better and could be scored as high or good for both directions, with a correlated improved reliability of the pressure characteristics. Reliability of multi-masking showed a similar pattern, but overall values tended to be lower. Therefore, small sized masking in order to define pressure characteristics in the forefoot should be done with care.

  7. Inter-rater reliability of shoulder measurements in middle-aged women.

    Science.gov (United States)

    De Groef, A; Van Kampen, M; Vervloesem, N; Clabau, E; Christiaens, M-R; Neven, P; Geraerts, I; Struyf, F; Devoogdt, N

    2017-06-01

    To investigate inter-rater reliability of a set of shoulder measurements including inclinometry [shoulder range of motion (ROM)], acromion-table distance and pectoralis minor muscle length (static scapular positioning), upward rotation with two inclinometers (scapular kinematics) and pain pressure thresholds (muscle tenderness) in middle-aged women. Observational study. Thirty symptom-free middle-aged women (first cohort) were measured by two raters. All measurements with an intraclass correlation coefficient (ICC) below 0.75 were retested after an additional training period in a second cohort of 30 symptom-free middle-aged women. Inter-rater reliability of all variables was measured with the ICC (95% confidence interval) and standard error of measurement (SEM). Acromion-table distance (ICC=0.91, SEM 0.22 to 0.28% of body length), pectoralis minor muscle length (ICC=0.91, SEM 0.16% of body length), pain pressure thresholds (ICC=0.78 to 0.85, SEM 0.39 to 0.70kg) and abduction ROM (ICC=0.77, SEM 5°) showed good to excellent inter-rater reliability in the first cohort. After an additional training period, forward flexion ROM showed good inter-rater reliability (ICC=0.83, SEM 5°), scapular upward rotation in resting position showed moderate reliability (ICC=0.52, SEM 2°), and other scaption angles showed weak reliability (ICC=0.26 to 0.43, SEM 3 to 8°). In a battery of clinical tools to evaluate factors contributing to shoulder pain, static scapular positioning and pressure pain thresholds were found to have good to excellent inter-rater reliability in middle-aged women. Additional training is recommended for measurements with a gravity inclinometer. Copyright © 2016 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  8. Inter-rater reliability of case-note audit: a systematic review.

    Science.gov (United States)

    Lilford, Richard; Edwards, Alex; Girling, Alan; Hofer, Timothy; Di Tanna, Gian Luca; Petty, Jane; Nicholl, Jon

    2007-07-01

    The quality of clinical care is often assessed by retrospective examination of case-notes (charts, medical records). Our objective was to determine the inter-rater reliability of case-note audit. We conducted a systematic review of the inter-rater reliability of case-note audit. Analysis was restricted to 26 papers reporting comparisons of two or three raters making independent judgements about the quality of care. Sixty-six separate comparisons were possible, since some papers reported more than one measurement of reliability. Mean kappa values ranged from 0.32 to 0.70. These may be inflated due to publication bias. Measured reliabilities were found to be higher for case-note reviews based on explicit, as opposed to implicit, criteria and for reviews that focused on outcome (including adverse effects) rather than process errors. We found an association between kappa and the prevalence of errors (poor quality care), suggesting alternatives such as tetrachoric and polychoric correlation coefficients be considered to assess inter-rater reliability. Comparative studies should take into account the relationship between kappa and the prevalence of the events being measured.

  9. High inter-rater reliability, agreement, and convergent validity of Constant score in patients with clavicle fractures

    DEFF Research Database (Denmark)

    Ban, Ilija; Troelsen, Anders; Kristensen, Morten Tange

    2016-01-01

    BACKGROUND: The Constant score (CS) has been the primary endpoint in most studies on clavicle fractures. However, the CS was not developed to assess patients with clavicle fractures. Our aim was to examine inter-rater reliability and agreement of the CS in patients with clavicle fractures...... standardized CS assessment at a mean of 6.8 weeks (SD, 1.0 weeks) after injury. Reliability and agreement of the CS were determined by 2 raters. The interclass correlation coefficient (ICC2,1), standard error of measurement, minimal detectable change, Cronbach α coefficient, and Pearson correlation coefficient...... were estimated. RESULTS: Inter-rater reliability of the total CS was excellent (interclass correlation coefficient, 0.94; 95% confidence interval, 0.88-0.97), with no systematic difference between the 2 raters (P = .75). The standard error of measurement (measurement error at the group level) was 4...

  10. Inter- and intra-rater reliability of nasal auscultation in daycare children.

    Science.gov (United States)

    Santos, Rita; Silva Alexandrino, Ana; Tomé, David; Melo, Cristina; Mesquita Montes, António; Costa, Daniel; Pinto Ferreira, João

    2018-02-01

    The aim of this study was to assess nasal auscultation's intra- and inter-rater reliability and to analyze ear and respiratory clinical condition according to nasal auscultation. Cross-sectional study performed in 125 children aged up to 3 years old attending daycare centers. Nasal auscultation, tympanometry and Paediatric Respiratory Severity Score (PRSS) were applied to all children. Nasal sounds were classified by an expert panel in order to determine nasal auscultation's intra and inter- rater reliability. The classification of nasal sounds was assessed against tympanometric and PRSS values. Nasal auscultation revealed substantial inter-rater (K=0.75) and intra-rater (K=0.69; K=0.61 and K=0.72) reliability. Children with a "non-obstructed" classification revealed a lower peak pressure (t=-3.599, Pauscultation revealed substantial intra- and inter-rater reliability. Nasal auscultation exhibited important differences according to ear and respiratory clinical conditions. Nasal auscultation in pediatrics seems to be an original topic as well as a simple method that can be used to identify early signs of nasopharyngeal obstruction.

  11. Intra-tester Reliability and Construct Validity of a Hip Abductor Eccentric Strength Test.

    Science.gov (United States)

    Brindle, Richard A; Ebaugh, D David; Milner, Clare E

    2017-11-15

    Side-lying hip abductor strength tests are commonly used to evaluate muscle strength. In a 'break' test the tester applies sufficient force to lower the limb to the table while the patient resists. The peak force is postulated to occur while the leg is lowering, thus representing the participant's eccentric muscle strength. However, it is unclear whether peak force occurs before or after the leg begins to lower. To determine intra-rater reliability and construct validity of a hip abductor eccentric strength test. Intra-rater reliability and construct validity study. Twenty healthy adults (26 ±6 years; 1.66 ±0.06 m; 62.2 ±8.0 kg) made two visits to the laboratory at least one week apart. During the hip abductor eccentric strength test, a hand-held dynamometer recorded peak force and time to peak force and limb position was recorded via a motion capture system. Intra-rater reliability was determined using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable difference (MDD). Construct validity was assessed by determining if peak force occurred after the start of the lowering phase using a one-sample t-test. The hip abductor eccentric strength test had substantial intra-rater reliability (ICC( 3,3 ) = 0.88; 95% confidence interval: 0.65-0.95), SEM of 0.9%BWh, and a MDD of 2.5%BWh. Construct validity was established as peak force occurred 2.1s (±0.6s; range 0.7s to 3.7s) after the start of the lowering phase of the test (p ≤ 0.001). The hip abductor eccentric strength test is a valid and reliable measure of eccentric muscle strength. This test may be used clinically to assess changes in eccentric muscle strength over time.

  12. Advanced TCA Backplane Tester

    CERN Document Server

    Oltean, Alexandra Dana

    2004-01-01

    At the beginning of 2003, the PICMG group adopted the AdvancedTCA (Advanced Telecom Computing Architecture) standard. The 10Gb/s backplane of the AdvancedTCA chassis is well specified in the standard but it remains however a high end product, which can be itself subject to printed circuit board manufacturing control problems that could greatly affect its quality control. In order to study the practical aspects of high speed Ethernet switching at 10Gb/s and to validate the signal integrity of the AdvancedTCA backplane, we developed a Backplane Tester. The tester system is able of running monitored PRBS traffic at 3.125Gb/s over every link on the AdvancedTCA backplane simultaneously and to monitor any possible connectivity failure immediately in terms of link and slot position inside the chassis. The present report presents the architectural hardware design, the control structure and software aspects of the AdvancedTCA Backplane Tester design.

  13. Inter-arch digital model vs. manual cast measurements: Accuracy and reliability.

    Science.gov (United States)

    Kiviahde, Heikki; Bukovac, Lea; Jussila, Päivi; Pesonen, Paula; Sipilä, Kirsi; Raustia, Aune; Pirttiniemi, Pertti

    2017-06-28

    The purpose of this study was to evaluate the accuracy and reliability of inter-arch measurements using digital dental models and conventional dental casts. Thirty sets of dental casts with permanent dentition were examined. Manual measurements were done with a digital caliper directly on the dental casts, and digital measurements were made on 3D models by two independent examiners. Intra-class correlation coefficients (ICC), a paired sample t-test or Wilcoxon signed-rank test, and Bland-Altman plots were used to evaluate intra- and inter-examiner error and to determine the accuracy and reliability of the measurements. The ICC values were generally good for manual and excellent for digital measurements. The Bland-Altman plots of all the measurements showed good agreement between the manual and digital methods and excellent inter-examiner agreement using the digital method. Inter-arch occlusal measurements on digital models are accurate and reliable and are superior to manual measurements.

  14. Inter- and intra-examiner reliability of footprint pattern analysis obtained from diabetics using the Harris mat.

    Science.gov (United States)

    Cisneros, Lígia de Loiola; Fonseca, Tiago H S; Abreu, Vivianni C

    2010-01-01

    High plantar pressure is a proven risk factor for ulceration among individuals with diabetes mellitus. The Harris and Beath footprinting mat is one of the tools used in screening for foot ulceration risk among these subjects. There are no reports in the literature on the reliability of footprint analysis using print pattern criteria. The aim of this study was to evaluate the inter- and intra-examiner reliability of the analysis of footprint patterns obtained using the Harris and Beath footprinting mat. Footprints were taken from 41 subjects using the footprinting mat. The images were subjected to analysis by three independent examiners. To investigate the intra-examiner reliability, the analysis was repeated by one of the examiners one week later. The weighted kappa coefficient was excellent (K(w) > 0.80) for the inter- and intra-examiner analyses for most of the points studied on both feet. The criteria for analyzing footprint patterns obtained using the Harris and Beath footprinting mat presented good reliability and high to excellent inter- and intra-examiner agreement. This method is reliable for analyses involving one or more examiners. Article registered in the Australian New Zealand Clinical Trials Registry (ANZCTR) under the number ACTRN12609000693224.

  15. Hydrogen fracture toughness tester completion

    Energy Technology Data Exchange (ETDEWEB)

    Morgan, Michael J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-09-30

    The Hydrogen Fracture Toughness Tester (HFTT) is a mechanical testing machine designed for conducting fracture mechanics tests on materials in high-pressure hydrogen gas. The tester is needed for evaluating the effects of hydrogen on the cracking properties of tritium reservoir materials. It consists of an Instron Model 8862 Electromechanical Test Frame; an Autoclave Engineering Pressure Vessel, an Electric Potential Drop Crack Length Measurement System, associated computer control and data acquisition systems, and a high-pressure hydrogen gas manifold and handling system.

  16. Inter-rater and intra-rater reliability of a movement control test in shoulder.

    Science.gov (United States)

    Rajasekar, S; Bangera, Rakshith K; Sekaran, Padmanaban

    2017-07-01

    Movement faults are commonly observed in patients with musculoskeletal pain. The Kinetic Medial Rotation Test (KMRT) is a movement control test used to identify movement faults of the scapula and gleno-humeral joints during arm movement. Objective tests such as the KMRT need to be reliable and valid for the results to be applied across different clinical settings and patient populations. The primary objective of the present study was to determine the intra-rater and inter-rater reliability of KMRT in subjects with and without shoulder pain. Sixty subjects were included in this study based on specific inclusion and exclusion criteria. Two musculoskeletal physiotherapists with different levels of clinical experience performed the tests. The intra-rater reliability was tested in twenty asymptomatic subjects by a single assessor at two week intervals. An equal number of subjects with and without shoulder pain were tested by both the assessors to determine the inter-rater reliability. Both components of the KMRT, the Gleno- Humeral Anterior Translation (GHAT) and the Scapular Forward Tilt (SCFT) were tested. The Kappa values for inter-rater reliability of the GHAT and SCFT were K = 0.68 & K = 0.65 respectively in subjects with shoulder pain. In asymptomatic subjects, the inter-rater reliability of GHAT was K = 0.61 and SCFT was K = 0.85. Intra-rater reliability ranged from K = 0.66 for GHAT to K = 0.87 for SCFT. Our study found substantial agreement in inter-rater reliability of KMRT in subjects with shoulder pain, whereas substantial to near perfect agreement was found in intra-rater and inter-rater reliability of KMRT in subjects without shoulder pain. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Exploring Differences in Measurement and Reporting of Classroom Observation Inter-Rater Reliability

    Science.gov (United States)

    Wilhelm, Anne Garrison; Gillespie Rouse, Amy; Jones, Francesca

    2018-01-01

    Although inter-rater reliability is an important aspect of using observational instruments, it has received little theoretical attention. In this article, we offer some guidance for practitioners and consumers of classroom observations so that they can make decisions about inter-rater reliability, both for study design and in the reporting of data…

  18. Cardiac valve calcifications on low-dose unenhanced ungated chest computed tomography: inter-observer and inter-examination reliability, agreement and variability

    International Nuclear Information System (INIS)

    Hamersvelt, Robbert W. van; Willemink, Martin J.; Takx, Richard A.P.; Eikendal, Anouk L.M.; Budde, Ricardo P.J.; Leiner, Tim; Jong, Pim A. de; Mol, Christian P.; Isgum, Ivana

    2014-01-01

    To determine inter-observer and inter-examination variability for aortic valve calcification (AVC) and mitral valve and annulus calcification (MC) in low-dose unenhanced ungated lung cancer screening chest computed tomography (CT). We included 578 lung cancer screening trial participants who were examined by CT twice within 3 months to follow indeterminate pulmonary nodules. On these CTs, AVC and MC were measured in cubic millimetres. One hundred CTs were examined by five observers to determine the inter-observer variability. Reliability was assessed by kappa statistics (κ) and intra-class correlation coefficients (ICCs). Variability was expressed as the mean difference ± standard deviation (SD). Inter-examination reliability was excellent for AVC (κ = 0.94, ICC = 0.96) and MC (κ = 0.95, ICC = 0.90). Inter-examination variability was 12.7 ± 118.2 mm 3 for AVC and 31.5 ± 219.2 mm 3 for MC. Inter-observer reliability ranged from κ = 0.68 to κ = 0.92 for AVC and from κ = 0.20 to κ = 0.66 for MC. Inter-observer ICC was 0.94 for AVC and ranged from 0.56 to 0.97 for MC. Inter-observer variability ranged from -30.5 ± 252.0 mm 3 to 84.0 ± 240.5 mm 3 for AVC and from -95.2 ± 210.0 mm 3 to 303.7 ± 501.6 mm 3 for MC. AVC can be quantified with excellent reliability on ungated unenhanced low-dose chest CT, but manual detection of MC can be subject to substantial inter-observer variability. Lung cancer screening CT may be used for detection and quantification of cardiac valve calcifications. (orig.)

  19. Feasibility and Inter-Rater Reliability of Physical Performance Measures in Acutely Admitted Older Medical Patients

    DEFF Research Database (Denmark)

    Bodilsen, Ann Christine; Juul-Larsen, Helle Gybel; Petersen, Janne

    2015-01-01

    OBJECTIVE: Physical performance measures can be used to predict functional decline and increased dependency in older persons. However, few studies have assessed the feasibility or reliability of such measures in hospitalized older patients. Here we assessed the feasibility and inter-rater reliabi......OBJECTIVE: Physical performance measures can be used to predict functional decline and increased dependency in older persons. However, few studies have assessed the feasibility or reliability of such measures in hospitalized older patients. Here we assessed the feasibility and inter......-rater reliability of four simple measures of physical performance in acutely admitted older medical patients. DESIGN: During the first 24 hours of hospitalization, the following were assessed twice by different raters in 52 (≥ 65 years) patients admitted for acute medical illness: isometric hand grip strength, 4......, and 30-s chair stand were 8%, 7%, and 18%, and the SRD95% values were 22%, 17%, and 49%. CONCLUSION: In acutely admitted older medical patients, grip strength, gait speed, and the Cumulated Ambulation Score measurements were feasible and showed high inter-rater reliability when administered by different...

  20. Cardiac valve calcifications on low-dose unenhanced ungated chest computed tomography: inter-observer and inter-examination reliability, agreement and variability

    Energy Technology Data Exchange (ETDEWEB)

    Hamersvelt, Robbert W. van; Willemink, Martin J.; Takx, Richard A.P.; Eikendal, Anouk L.M.; Budde, Ricardo P.J.; Leiner, Tim; Jong, Pim A. de [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Mol, Christian P.; Isgum, Ivana [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands)

    2014-07-15

    To determine inter-observer and inter-examination variability for aortic valve calcification (AVC) and mitral valve and annulus calcification (MC) in low-dose unenhanced ungated lung cancer screening chest computed tomography (CT). We included 578 lung cancer screening trial participants who were examined by CT twice within 3 months to follow indeterminate pulmonary nodules. On these CTs, AVC and MC were measured in cubic millimetres. One hundred CTs were examined by five observers to determine the inter-observer variability. Reliability was assessed by kappa statistics (κ) and intra-class correlation coefficients (ICCs). Variability was expressed as the mean difference ± standard deviation (SD). Inter-examination reliability was excellent for AVC (κ = 0.94, ICC = 0.96) and MC (κ = 0.95, ICC = 0.90). Inter-examination variability was 12.7 ± 118.2 mm{sup 3} for AVC and 31.5 ± 219.2 mm{sup 3} for MC. Inter-observer reliability ranged from κ = 0.68 to κ = 0.92 for AVC and from κ = 0.20 to κ = 0.66 for MC. Inter-observer ICC was 0.94 for AVC and ranged from 0.56 to 0.97 for MC. Inter-observer variability ranged from -30.5 ± 252.0 mm{sup 3} to 84.0 ± 240.5 mm{sup 3} for AVC and from -95.2 ± 210.0 mm{sup 3} to 303.7 ± 501.6 mm{sup 3} for MC. AVC can be quantified with excellent reliability on ungated unenhanced low-dose chest CT, but manual detection of MC can be subject to substantial inter-observer variability. Lung cancer screening CT may be used for detection and quantification of cardiac valve calcifications. (orig.)

  1. Test-re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females.

    Science.gov (United States)

    Beardsley, Chris; Egerton, Tim; Skinner, Brendon

    2016-01-01

    Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test-re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81-0.88), test-re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88-0.95), and test-re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65) and good on the right side (ICC = 0.85). Conclusion. Inter-rater reliability and test-re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test-re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test-re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.

  2. 3-D high-frequency endovaginal ultrasound of female urethral complex and assessment of inter-observer reliability

    International Nuclear Information System (INIS)

    Wieczorek, A.P.; Wozniak, M.M.; Stankiewicz, A.; Santoro, G.A.; Bogusiewicz, M.; Rechberger, T.

    2012-01-01

    Objectives: Assessment of the urethral complex and defining its morphological characteristics with 3-dimensional endovaginal ultrasonography with the use of high frequency rotational 360° transducer. Defining inter-observer reliability of the performed measurements. Materials and methods: Twenty-four asymptomatic, nulliparous females (aged 18–55, mean 32 years) underwent high-frequency (12 MHz) endovaginal ultrasound with rotational 360° and automated 3D data acquisition (type 2050, B-K Medical, Herlev, Denmark). Measurements of the urethral thickness, width and length, bladder neck-symphysis distance, intramural part of the urethra as well as rhabdosphincter thickness, width and length were taken by three investigators. Descriptive statistics for continuous data was performed. The results were given as mean values with standard deviation. The relationships among different variables were assessed with ANOVA for repeated measures factors, as well as T-test for dependent samples. Intraclass correlation (ICC) was calculated for each parameter. Intra- and interobserver reliability was assessed. Statistical significance was assigned to a P value of 0.8) and good reliability for rhabdosphincter measurements (ICC > 0.6) between all three investigators. Conclusions: Advanced EVUS provides detailed information on anatomy and morphology of the female urethral complex. Our results show that 360° rotational transducer with automated 3D acquisition, currently routinely used for proctological scanning is suitable for the reliable assessment of the urethral complex and can be applied in a routine diagnostics of pelvic floor disturbances in females.

  3. Test–re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females

    Directory of Open Access Journals (Sweden)

    Chris Beardsley

    2016-03-01

    Full Text Available Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test–re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81–0.88, test–re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88–0.95, and test–re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65 and good on the right side (ICC = 0.85. Conclusion. Inter-rater reliability and test–re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test–re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test–re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.

  4. The reliability of language performance measurement in language sample analysis of children aged 5-6 years

    Directory of Open Access Journals (Sweden)

    Zahra Soleymani

    2014-04-01

    Full Text Available Background and Aim: The language sample analysis (LSA is more common in other languages than Persian to study language development and assess language pathology. We studied some psychometric properties of language sample analysis in this research such as content validity of written story and its pictures, test-retest reliability, and inter-rater reliability.Methods: We wrote a story based on Persian culture from Schneider’s study. The validity of written story and drawn pictures was approved by experts. To study test-retest reliability, 30 children looked at the pictures and told their own story twice with 7-10 days interval. Children generated the story themselves and tester did not give any cue about the story. Their audio-taped story was transcribed and analyzed. Sentence and word structures were detected in the analysis.Results: Mean of experts' agreement with the validity of written story was 92.28 percent. Experts scored the quality of pictures high and excellent. There was correlation between variables in sentence and word structure (p<0.05 in test-retest, except complex sentences (p=0.137. The agreement rate was 97.1 percent in inter-rater reliability assessment of transcription. The results of inter-rater reliability of language analysis showed that correlation coefficients were significant.Conclusion: The results confirmed that the tool was valid for eliciting language sample. The consistency of language performance in repeated measurement varied from mild to high in language sample analysis approach.

  5. Hip strength assessment using handheld dynamometry is subject to intertester bias when testers are of different sex and strength

    DEFF Research Database (Denmark)

    Thorborg, K; Bandholm, T; Schick, M

    2013-01-01

    Handheld dynamometry (HHD) is a promising tool for obtaining reliable hip strength measurements in the clinical setting, but intertester reliability has been questioned, especially in situations where testers exhibit differences in upper-extremity muscle strength (male vs female). The purpose...... of this study was to examine the intertester reliability concerning strength assessments of hip abduction, adduction, external and internal rotation, flexion and extension using HHD, and to test whether systematic differences in test values exist between testers of different upper-extremity strength. Fifty...... healthy individuals (29 women), aged 25 ± 5 years were included. Two physiotherapist students (one female, one male) of different upper-extremity strength performed the measurements. The tester order and strength test order were randomized. Intraclass correlation coefficients were used to quantify...

  6. Inter-rater and intra-rater reliability of a clinical protocol for measuring turnout in collegiate dancers.

    Science.gov (United States)

    Greene, Amanda; Lasner, Andrea; Deu, Rajwinder; Oliphant, Seth; Johnson, Kenneth

    2018-02-02

    Reliable methods of measuring turnout in dancers and comparing active turnout (used in class) with functional (uncompensated) turnout are needed. Authors have suggested measurement techniques but there is no clinically useful, easily reproducible technique with established inter-rater and intra-rater reliability. We adapted a technique based on previous research, which is easily reproducible. We hypothesized excellent inter-rater and intra-rater reliability between experienced physical therapists (PTs) and a briefly trained faculty member from a university's department of dance. Thirty-two participants were recruited from the same dance department. Dancers' active and functional turnout was measured by each rater. We found that our technique for measuring active and functional turnout has excellent inter-rater and intra-rater reliability when performed by two experienced PTs and by one briefly trained university-level dance faculty member. For active turnout, inter-rater reliability was 0.78 among all raters and 0.82 among only the PT raters; intra-rater reliability was 0.82 among all raters and 0.85 among only the PT raters. For functional turnout, inter-rater reliability was 0.86 among all raters and 0.88 among only the PT raters; intra-rater reliability was 0.87 among all raters and 0.88 among only the PT raters. The measurement technique described provides a standardized protocol with excellent inter-rater and intra-rater reliability when performed by experienced PTs or by a briefly trained university-level dance faculty member.

  7. Grant Peer Review: Improving Inter-Rater Reliability with Training.

    Science.gov (United States)

    Sattler, David N; McKnight, Patrick E; Naney, Linda; Mathis, Randy

    2015-01-01

    This study developed and evaluated a brief training program for grant reviewers that aimed to increase inter-rater reliability, rating scale knowledge, and effort to read the grant review criteria. Enhancing reviewer training may improve the reliability and accuracy of research grant proposal scoring and funding recommendations. Seventy-five Public Health professors from U.S. research universities watched the training video we produced and assigned scores to the National Institutes of Health scoring criteria proposal summary descriptions. For both novice and experienced reviewers, the training video increased scoring accuracy (the percentage of scores that reflect the true rating scale values), inter-rater reliability, and the amount of time reading the review criteria compared to the no video condition. The increase in reliability for experienced reviewers is notable because it is commonly assumed that reviewers--especially those with experience--have good understanding of the grant review rating scale. The findings suggest that both experienced and novice reviewers who had not received the type of training developed in this study may not have appropriate understanding of the definitions and meaning for each value of the rating scale and that experienced reviewers may overestimate their knowledge of the rating scale. The results underscore the benefits of and need for specialized peer reviewer training.

  8. Intra-rater and inter-rater reliability of a medical record abstraction study on transition of care after childhood cancer.

    Directory of Open Access Journals (Sweden)

    Micòl E Gianinazzi

    Full Text Available The abstraction of data from medical records is a widespread practice in epidemiological research. However, studies using this means of data collection rarely report reliability. Within the Transition after Childhood Cancer Study (TaCC which is based on a medical record abstraction, we conducted a second independent abstraction of data with the aim to assess a intra-rater reliability of one rater at two time points; b the possible learning effects between these two time points compared to a gold-standard; and c inter-rater reliability.Within the TaCC study we conducted a systematic medical record abstraction in the 9 Swiss clinics with pediatric oncology wards. In a second phase we selected a subsample of medical records in 3 clinics to conduct a second independent abstraction. We then assessed intra-rater reliability at two time points, the learning effect over time (comparing each rater at two time-points with a gold-standard and the inter-rater reliability of a selected number of variables. We calculated percentage agreement and Cohen's kappa.For the assessment of the intra-rater reliability we included 154 records (80 for rater 1; 74 for rater 2. For the inter-rater reliability we could include 70 records. Intra-rater reliability was substantial to excellent (Cohen's kappa 0-6-0.8 with an observed percentage agreement of 75%-95%. In all variables learning effects were observed. Inter-rater reliability was substantial to excellent (Cohen's kappa 0.70-0.83 with high agreement ranging from 86% to 100%.Our study showed that data abstracted from medical records are reliable. Investigating intra-rater and inter-rater reliability can give confidence to draw conclusions from the abstracted data and increase data quality by minimizing systematic errors.

  9. Inter-rater reliability of nursing home quality indicators in the U.S

    Directory of Open Access Journals (Sweden)

    Roy Jason

    2003-11-01

    Full Text Available Abstract Background In the US, Quality Indicators (QI's profiling and comparing the performance of hospitals, health plans, nursing homes and physicians are routinely published for consumer review. We report the results of the largest study of inter-rater reliability done on nursing home assessments which generate the data used to derive publicly reported nursing home quality indicators. Methods We sampled nursing homes in 6 states, selecting up to 30 residents per facility who were observed and assessed by research nurses on 100 clinical assessment elements contained in the Minimum Data Set (MDS and compared these with the most recent assessment in the record done by facility nurses. Kappa statistics were generated for all data items and derived for 22 QI's over the entire sample and for each facility. Finally, facilities with many QI's with poor Kappa levels were compared to those with many QI's with excellent Kappa levels on selected characteristics. Results A total of 462 facilities in 6 states were approached and 219 agreed to participate, yielding a response rate of 47.4%. A total of 5758 residents were included in the inter-rater reliability analyses, around 27.5 per facility. Patients resembled the traditional nursing home resident, only 43.9% were continent of urine and only 25.2% were rated as likely to be discharged within the next 30 days. Results of resident level comparative analyses reveal high inter-rater reliability levels (most items >.75. Using the research nurses as the "gold standard", we compared composite quality indicators based on their ratings with those based on facility nurses. All but two QI's have adequate Kappa levels and 4 QI's have average Kappa values in excess of .80. We found that 16% of participating facilities performed poorly (Kappa .75 on 12 or more QI's. No facility characteristics were related to reliability of the data on which Qis are based. Conclusion While a few QI's being used for public reporting

  10. Poppet valve tester

    Science.gov (United States)

    Tellier, G. F.

    1973-01-01

    Tester investigates fundamental factors affecting cyclic life and sealing performance of valve seats and poppets. Tester provides for varying impact loading of poppet against seat and rate of cycling, and controls amount and type of relative motion between sealing faces of seat and poppet. Relative motion between seat and poppet can be varied in three modes.

  11. Analyses of inter-rater reliability between professionals, medical students and trained school children as assessors of basic life support skills.

    Science.gov (United States)

    Beck, Stefanie; Ruhnke, Bjarne; Issleib, Malte; Daubmann, Anne; Harendza, Sigrid; Zöllner, Christian

    2016-10-07

    Training of lay-rescuers is essential to improve survival-rates after cardiac arrest. Multiple campaigns emphasise the importance of basic life support (BLS) training for school children. Trainings require a valid assessment to give feedback to school children and to compare the outcomes of different training formats. Considering these requirements, we developed an assessment of BLS skills using MiniAnne and tested the inter-rater reliability between professionals, medical students and trained school children as assessors. Fifteen professional assessors, 10 medical students and 111-trained school children (peers) assessed 1087 school children at the end of a CPR-training event using the new assessment format. Analyses of inter-rater reliability (intraclass correlation coefficient; ICC) were performed. Overall inter-rater reliability of the summative assessment was high (ICC = 0.84, 95 %-CI: 0.84 to 0.86, n = 889). The number of comparisons between peer-peer assessors (n = 303), peer-professional assessors (n = 339), and peer-student assessors (n = 191) was adequate to demonstrate high inter-rater reliability between peer- and professional-assessors (ICC: 0.76), peer- and student-assessors (ICC: 0.88) and peer- and other peer-assessors (ICC: 0.91). Systematic variation in rating of specific items was observed for three items between professional- and peer-assessors. Using this assessment and integrating peers and medical students as assessors gives the opportunity to assess hands-on skills of school children with high reliability.

  12. Tester-assisted built in test

    Science.gov (United States)

    Guntheroth, Kurt

    It is noted that board makers invest considerable time and money writing extensive self-tests and that this investment can be multiplied by selecting ATE (automatic test equipment) that complements and extends the power of the self-test. The tester can diagnose boards in situations where a fault prevents the self-test from running. If the tester monitors such resources as processor, memory, and I/O, confidence in test results is improved. The tester can be used during development of the self-test and to turn on prototypes before the self-test is complete. The author argues that emulative functional testers outperform other types of ATE on boards with BIST (built-in self-test) and lists features of emulative functional testers that are most important to users of BIST.

  13. Inter-rater reliability of measures to characterize the tobacco retail environment in Mexico

    Directory of Open Access Journals (Sweden)

    Marissa G Hall

    2015-11-01

    Full Text Available Objective. To evaluate the inter-rater reliability of a data collection instrument to assess the tobacco retail environ- ment in Mexico, after major marketing regulations were implemented. Materials and methods. In 2013, two data collectors independently evaluated 21 stores in two census tracts, through a data collection instrument that assessed the presence of price promotions, whether single cigarettes were sold, the number of visible advertisements, the pre- sence of signage prohibiting the sale of cigarettes to minors, and characteristics of cigarette pack displays. We evaluated the inter-rater reliability of the collected data, through the calculation of metrics such as intraclass correlation coefficient, percent agreement, Cohen’s kappa and Krippendorff’s alpha. Results. Most measures demonstrated substantial or perfect inter-rater reliability. Conclusions. Our results indicate the potential utility of the data collection instrument for future point-of-sale research.

  14. Inter-rater reliability of AMSTAR is dependent on the pair of reviewers.

    Science.gov (United States)

    Pieper, Dawid; Jacobs, Anja; Weikert, Beate; Fishta, Alba; Wegewitz, Uta

    2017-07-11

    Inter-rater reliability (IRR) is mainly assessed based on only two reviewers of unknown expertise. The aim of this paper is to examine differences in the IRR of the Assessment of Multiple Systematic Reviews (AMSTAR) and R(evised)-AMSTAR depending on the pair of reviewers. Five reviewers independently applied AMSTAR and R-AMSTAR to 16 systematic reviews (eight Cochrane reviews and eight non-Cochrane reviews) from the field of occupational health. Responses were dichotomized and reliability measures were calculated by applying Holsti's method (r) and Cohen's kappa (κ) to all potential pairs of reviewers. Given that five reviewers participated in the study, there were ten possible pairs of reviewers. Inter-rater reliability varied for AMSTAR between r = 0.82 and r = 0.98 (median r = 0.88) using Holsti's method and κ = 0.41 and κ = 0.69 (median κ = 0.52) using Cohen's kappa and for R-AMSTAR between r = 0.77 and r = 0.89 (median r = 0.82) and κ = 0.32 and κ = 0.67 (median κ = 0.45) depending on the pair of reviewers. The same pair of reviewers yielded the highest IRR for both instruments. Pairwise Cohen's kappa reliability measures showed a moderate correlation between AMSTAR and R-AMSTAR (Spearman's ρ =0.50). The mean inter-rater reliability for AMSTAR was highest for item 1 (κ = 1.00) and item 5 (κ = 0.78), while lowest values were found for items 3, 8, 9 and 11, which showed only fair agreement. Inter-rater reliability varies widely depending on the pair of reviewers. There may be some shortcomings associated with conducting reliability studies with only two reviewers. Further studies should include additional reviewers and should probably also take account of their level of expertise.

  15. Allied health clinicians using translational research in action to develop a reliable stroke audit tool.

    Science.gov (United States)

    Abery, Philip; Kuys, Suzanne; Lynch, Mary; Low Choy, Nancy

    2018-05-23

    To design and establish reliability of a local stroke audit tool by engaging allied health clinicians within a privately funded hospital. Design: Two-stage study involving a modified Delphi process to inform stroke audit tool development and inter-tester reliability. Allied health clinicians. A modified Delphi process to select stroke guideline recommendations for inclusion in the audit tool. Reliability study: 1 allied health representative from each discipline audited 10 clinical records with sequential admissions to acute and rehabilitation services. Recommendations were admitted to the audit tool when 70% agreement was reached, with 50% set as the reserve agreement. Inter-tester reliability was determined using intra-class correlation coefficients (ICCs) across 10 clinical records. Twenty-two participants (92% female, 50% physiotherapists, 17% occupational therapists) completed the modified Delphi process. Across 6 voting rounds, 8 recommendations reached 70% agreement and 2 reached 50% agreement. Two recommendations (nutrition/hydration; goal setting) were added to ensure representation for all disciplines. Substantial consistency across raters was established for the audit tool applied in acute stroke (ICC .71; range .48 to .90) and rehabilitation (ICC.78; range .60 to .93) services. Allied health clinicians within a privately funded hospital generally agreed in an audit process to develop a reliable stroke audit tool. Allied health clinicians agreed on stroke guideline recommendations to inform a stroke audit tool. The stroke audit tool demonstrated substantial consistency supporting future use for service development. This process, which engages local clinicians, could be adopted by other facilities to design reliable audit tools to identify local service gaps to inform changes to clinical practice. © 2018 John Wiley & Sons, Ltd.

  16. Inter-day Reliability of the IDEEA Activity Monitor for Measuring Movement and Non-Movement Behaviors in Older Adults.

    Science.gov (United States)

    de la Cámara, Miguel Ángel; Higueras-Fresnillo, Sara; Martinez-Gomez, David; Veiga, Oscar L

    2018-05-29

    The inter-day reliability of the Intelligent Device for Energy Expenditure and Activity (IDEEA) has not been studied to date. The study purpose was to examine the inter-day variability and reliability on two consecutive days collected with the IDEEA, as well as to predict the number of days needed to provide a reliable estimate of several movement (walking and climbing stairs) and non-movement behaviors (lying, reclining, sitting) and standing in older adults. The sample included 126 older adults (74 women) who wore the IDEEA for 48-h. Results showed low variability between the two days and its reliability was from moderate (ICC=0.34) to high (ICC=0.80) in most of movement and non-movement behaviors analyzed. The Bland-Altman plots showed a high-moderate agreement between days and the Spearman-Brown formula estimated ranged from 1.2 and 9.1 days of monitoring with the IDEEA are needed to achieve ICCs≥0.70 in older adults for sitting and climbing stairs, respectively.

  17. Inter- and Intraexaminer Reliability in Identifying and Classifying Myofascial Trigger Points in Shoulder Muscles.

    Science.gov (United States)

    Nascimento, José Diego Sales do; Alburquerque-Sendín, Francisco; Vigolvino, Lorena Passos; Oliveira, Wandemberg Fortunato de; Sousa, Catarina de Oliveira

    2018-01-01

    To determine inter- and intraexaminer reliability of examiners without clinical experience in identifying and classifying myofascial trigger points (MTPs) in the shoulder muscles of subjects asymptomatic and symptomatic for unilateral subacromial impact syndrome (SIS). Within-day inter- and intraexaminer reliability study. Physical therapy department of a university. Fifty-two subjects participated in the study, 26 symptomatic and 26 asymptomatic for unilateral SIS. Two examiners, without experience for assessing MTPs, independent and blind to the clinical conditions of the subjects, assessed bilaterally the presence of MTPs (present or absent) in 6 shoulder muscles and classified them (latent or active) on the affected side of the symptomatic group. Each examiner performed the same assessment twice in the same day. Reliability was calculated through percentage agreement, prevalence- and bias-adjusted kappa (PABAK) statistics, and weighted kappa. Intraexaminer reliability in identifying MTPs for the symptomatic and asymptomatic groups was moderate to perfect (PABAK, .46-1 and .60-1, respectively). Interexaminer reliability was between moderate and almost perfect in the 2 groups (PABAK, .46-.92), except for the muscles of the symptomatic group, which were below these values. With respect to MTP classification, intraexaminer reliability was moderate to high for most muscles, but interexaminer reliability was moderate for only 1 muscle (weighted κ=.45), and between weak and reasonable for the rest (weighted κ=.06-.31). Intraexaminer reliability is acceptable in clinical practice to identify and classify MTPs. However, interexaminer reliability proved to be reliable only to identify MTPs, with the symptomatic side exhibiting lower values of reliability. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  18. Inter-Rater Reliability of Provider Interpretations of Irritable Bowel Syndrome Food and Symptom Journals.

    Science.gov (United States)

    Zia, Jasmine; Chung, Chia-Fang; Xu, Kaiyuan; Dong, Yi; Schenk, Jeanette M; Cain, Kevin; Munson, Sean; Heitkemper, Margaret M

    2017-11-04

    There are currently no standardized methods for identifying trigger food(s) from irritable bowel syndrome (IBS) food and symptom journals. The primary aim of this study was to assess the inter-rater reliability of providers' interpretations of IBS journals. A second aim was to describe whether these interpretations varied for each patient. Eight providers reviewed 17 IBS journals and rated how likely key food groups (fermentable oligo-di-monosaccharides and polyols, high-calorie, gluten, caffeine, high-fiber) were to trigger IBS symptoms for each patient. Agreement of trigger food ratings was calculated using Krippendorff's α-reliability estimate. Providers were also asked to write down recommendations they would give to each patient. Estimates of agreement of trigger food likelihood ratings were poor (average α = 0.07). Most providers gave similar trigger food likelihood ratings for over half the food groups. Four providers gave the exact same written recommendation(s) (range 3-7) to over half the patients. Inter-rater reliability of provider interpretations of IBS food and symptom journals was poor. Providers favored certain trigger food likelihood ratings and written recommendations. This supports the need for a more standardized method for interpreting these journals and/or more rigorous techniques to accurately identify personalized IBS food triggers.

  19. Inter-Rater Reliability of Provider Interpretations of Irritable Bowel Syndrome Food and Symptom Journals

    Directory of Open Access Journals (Sweden)

    Jasmine Zia

    2017-11-01

    Full Text Available There are currently no standardized methods for identifying trigger food(s from irritable bowel syndrome (IBS food and symptom journals. The primary aim of this study was to assess the inter-rater reliability of providers’ interpretations of IBS journals. A second aim was to describe whether these interpretations varied for each patient. Eight providers reviewed 17 IBS journals and rated how likely key food groups (fermentable oligo-di-monosaccharides and polyols, high-calorie, gluten, caffeine, high-fiber were to trigger IBS symptoms for each patient. Agreement of trigger food ratings was calculated using Krippendorff’s α-reliability estimate. Providers were also asked to write down recommendations they would give to each patient. Estimates of agreement of trigger food likelihood ratings were poor (average α = 0.07. Most providers gave similar trigger food likelihood ratings for over half the food groups. Four providers gave the exact same written recommendation(s (range 3–7 to over half the patients. Inter-rater reliability of provider interpretations of IBS food and symptom journals was poor. Providers favored certain trigger food likelihood ratings and written recommendations. This supports the need for a more standardized method for interpreting these journals and/or more rigorous techniques to accurately identify personalized IBS food triggers.

  20. UW VLSI chip tester

    Science.gov (United States)

    McKenzie, Neil

    1989-12-01

    We present a design for a low-cost, functional VLSI chip tester. It is based on the Apple MacIntosh II personal computer. It tests chips that have up to 128 pins. All pin drivers of the tester are bidirectional; each pin is programmed independently as an input or an output. The tester can test both static and dynamic chips. Rudimentary speed testing is provided. Chips are tested by executing C programs written by the user. A software library is provided for program development. Tests run under both the Mac Operating System and A/UX. The design is implemented using Xilinx Logic Cell Arrays. Price/performance tradeoffs are discussed.

  1. Spring performance tester for miniature extension springs

    Science.gov (United States)

    Salzbrenner, Bradley; Boyce, Brad

    2017-05-16

    A spring performance tester and method of testing a spring are disclosed that has improved accuracy and precision over prior art spring testers. The tester can perform static and cyclic testing. The spring tester can provide validation for product acceptance as well as test for cyclic degradation of springs, such as the change in the spring rate and fatigue failure.

  2. Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements

    Directory of Open Access Journals (Sweden)

    Natalia M. Martinho

    2015-04-01

    Full Text Available OBJECTIVE: The aim of this study was to evaluate the intra and inter-rater reliability of pelvic floor muscle (PFM dynamometric measurements for maximum and average strengths, as well as endurance. METHOD: A convenience sample of 18 nulliparous women, without any urogynecological complaints, aged between 19 and 31 (mean age of 25.4±3.9 participated in this study. They were evaluated using a pelvic floor dynamometer based on load cell technology. The dynamometric evaluations were repeated in three successive sessions: two on the same day with a rest period of 30 minutes between them, and the third on the following day. All participants were evaluated twice in each session; first by examiner 1 followed by examiner 2. The vaginal dynamometry data were analyzed using three parameters: maximum strength, average strength, and endurance. The Intraclass Correlation Coefficient (ICC was applied to estimate the PFM dynamometric measurement reliability, considering a good level as being above 0.75. RESULTS: The intra and inter-raters' analyses showed good reliability for maximum strength (ICCintra-rater1=0.96, ICCintra-rater2=0.95, and ICCinter-rater=0.96, average strength (ICCintra-rater1=0.96, ICCintra-rater2=0.94, and ICCinter-rater=0.97, and endurance (ICCintra-rater1=0.88, ICCintra-rater2=0.86, and ICCinter-rater=0.92 dynamometric measurements. CONCLUSIONS: The PFM dynamometric measurements showed good intra- and inter-rater reliability for maximum strength, average strength and endurance, which demonstrates that this is a reliable device that can be used in clinical practice.

  3. Common tester platform concept.

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, Michael James

    2008-05-01

    This report summarizes the results of a case study on the doctrine of a common tester platform, a concept of a standardized platform that can be applicable across the broad spectrum of testing requirements throughout the various stages of a weapons program, as well as across the various weapons programs. The common tester concept strives to define an affordable, next-generation design that will meet testing requirements with the flexibility to grow and expand; supporting the initial development stages of a weapons program through to the final production and surveillance stages. This report discusses a concept investing key leveraging technologies and operational concepts combined with prototype tester-development experiences and practical lessons learned gleaned from past weapons programs.

  4. Inter-rater reliability of kinesthetic measurements with the KINARM robotic exoskeleton.

    Science.gov (United States)

    Semrau, Jennifer A; Herter, Troy M; Scott, Stephen H; Dukelow, Sean P

    2017-05-22

    Kinesthesia (sense of limb movement) has been extremely difficult to measure objectively, especially in individuals who have survived a stroke. The development of valid and reliable measurements for proprioception is important to developing a better understanding of proprioceptive impairments after stroke and their impact on the ability to perform daily activities. We recently developed a robotic task to evaluate kinesthetic deficits after stroke and found that the majority (~60%) of stroke survivors exhibit significant deficits in kinesthesia within the first 10 days post-stroke. Here we aim to determine the inter-rater reliability of this robotic kinesthetic matching task. Twenty-five neurologically intact control subjects and 15 individuals with first-time stroke were evaluated on a robotic kinesthetic matching task (KIN). Subjects sat in a robotic exoskeleton with their arms supported against gravity. In the KIN task, the robot moved the subjects' stroke-affected arm at a preset speed, direction and distance. As soon as subjects felt the robot begin to move their affected arm, they matched the robot movement with the unaffected arm. Subjects were tested in two sessions on the KIN task: initial session and then a second session (within an average of 18.2 ± 13.8 h of the initial session for stroke subjects), which were supervised by different technicians. The task was performed both with and without the use of vision in both sessions. We evaluated intra-class correlations of spatial and temporal parameters derived from the KIN task to determine the reliability of the robotic task. We evaluated 8 spatial and temporal parameters that quantify kinesthetic behavior. We found that the parameters exhibited moderate to high intra-class correlations between the initial and retest conditions (Range, r-value = [0.53-0.97]). The robotic KIN task exhibited good inter-rater reliability. This validates the KIN task as a reliable, objective method for quantifying

  5. Quality of nursing intensity data: inter-rater reliability of the patient classification after two decades in clinical use.

    Science.gov (United States)

    Liljamo, Pia; Kinnunen, Ulla-Mari; Ohtonen, Pasi; Saranto, Kaija

    2017-09-01

    The aim of this study was to measure the inter-rater reliability of the Oulu Patient Classification and to discuss existing methods of reliability testing. The Oulu Patient Classification, part of the RAFAELA ® System, has been developed to assist nursing managers with the proper allocation of nursing resources. Due to the increased intensity of inpatient care during recent years, there is a need for the reliability testing of the classification, which has been in clinical use for 20 years. Retrospective statistical study. To test inter-rater reliability, a pair of nurses classified the same patients, without knowledge of each other's ratings, as a part of annually conducted standardization. Data on the parallel classifications (n = 19,997) was obtained from inpatient units (n = 32) with different specialties at a university hospital in Finland during 2010-2015. Parallel classification practices were also analysed. The reliability of the overall classification and its subareas were calculated using suitable statistical coefficients. Inter-rater reliability coefficients were a reliable or almost perfect means of considering the nursing intensity category and various practices, but there were detectable differences between subareas. The lowest agreement levels occurred in the subareas 'Planning and Coordination of Nursing Care' and 'Guiding of Care/Continued Care and Emotional Support'. There is a need to develop the descriptions of subareas and to clarify the related concepts. Precise nursing documentation can promote a high level of agreement and reliable results. The traditional overall proportion of agreement does not provide an adequate picture of reliability - weighted kappa coefficients should be used instead. © 2017 John Wiley & Sons Ltd.

  6. Inter- and intra- observer reliability of risk assessment of repetitive work without an explicit method.

    Science.gov (United States)

    Eliasson, Kristina; Palm, Peter; Nyman, Teresia; Forsman, Mikael

    2017-07-01

    A common way to conduct practical risk assessments is to observe a job and report the observed long term risks for musculoskeletal disorders. The aim of this study was to evaluate the inter- and intra-observer reliability of ergonomists' risk assessments without the support of an explicit risk assessment method. Twenty-one experienced ergonomists assessed the risk level (low, moderate, high risk) of eight upper body regions, as well as the global risk of 10 video recorded work tasks. Intra-observer reliability was assessed by having nine of the ergonomists repeat the procedure at least three weeks after the first assessment. The ergonomists made their risk assessment based on his/her experience and knowledge. The statistical parameters of reliability included agreement in %, kappa, linearly weighted kappa, intraclass correlation and Kendall's coefficient of concordance. The average inter-observer agreement of the global risk was 53% and the corresponding weighted kappa (K w ) was 0.32, indicating fair reliability. The intra-observer agreement was 61% and 0.41 (K w ). This study indicates that risk assessments of the upper body, without the use of an explicit observational method, have non-acceptable reliability. It is therefore recommended to use systematic risk assessment methods to a higher degree. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Science.gov (United States)

    Tidstrand, Johan; Horneij, Eva

    2009-01-01

    Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs). Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ) and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0), for sitting on a Bobath ball good (κ: 0.79) and very good (κ: 0.88) and for the unilateral pelvic lift: good (κ: 0.61) and moderate (κ: 0.47). Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their ability to evaluate lumbar

  8. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Directory of Open Access Journals (Sweden)

    Tidstrand Johan

    2009-06-01

    Full Text Available Abstract Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs. Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0, for sitting on a Bobath ball good (κ: 0.79 and very good (κ: 0.88 and for the unilateral pelvic lift: good (κ: 0.61 and moderate (κ: 0.47. Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their

  9. Advanced TCA BAckplane Tester

    CERN Document Server

    Oltean, Alexandra Dana; PGNet2005

    2005-01-01

    The “Advanced Telecom Computing Architecture” (AdvancedTCA) is a modular standard chassis based system designed to support the needs of carrier class telecommunication applications. It is defined by a set of industry standards under the direction of the PICMG group. One early deployment of the standard technology has been a 10 Gigabit Ethernet switch developed in the framework of the EU funded ESTA project. In order to study the practical aspects of high speed Ethernet switching at 10 Gigabit and above and to validate the signal integrity of the AdvancedTCA backplane, we developed a Backplane Tester. This system is able to run pseudo-random bit sequence (PRBS) traffic at 3.125 Gbps over every link on the AdvancedTCA backplane simultaneously, and to monitor any possible connectivity failure immediately in terms of the link and slot positions inside the chassis. In this paper, we describe the design and the practical architectural hardware and software aspects of the AdvancedTCA Backplane Tester. We also pr...

  10. Inter-expert and intra-expert reliability in sleep spindle scoring

    DEFF Research Database (Denmark)

    Wendt, Sabrina Lyngbye; Welinder, Peter; Sørensen, Helge Bjarup Dissing

    2015-01-01

    Objectives To measure the inter-expert and intra-expert agreement in sleep spindle scoring, and to quantify how many experts are needed to build a reliable dataset of sleep spindle scorings. Methods The EEG dataset was comprised of 400 randomly selected 115 s segments of stage 2 sleep from 110...... with higher reliability than the estimation of spindle duration. Reliability of sleep spindle scoring can be improved by using qualitative confidence scores, rather than a dichotomous yes/no scoring system. Conclusions We estimate that 2–3 experts are needed to build a spindle scoring dataset...... with ‘substantial’ reliability (κ: 0.61–0.8), and 4 or more experts are needed to build a dataset with ‘almost perfect’ reliability (κ: 0.81–1). Significance Spindle scoring is a critical part of sleep staging, and spindles are believed to play an important role in development, aging, and diseases of the nervous...

  11. Research on characteristics measurement of infrared defect tester

    Science.gov (United States)

    Zhang, Ke-jia; Zhang, Bi-feng; Xiong, Li-min; Zhou, Tao-geng; Zhang, Jun-chao; Meng, Hai-feng; Cai, Chuan; He, Ying-wei; Li, Xiao-hui; Wang, Chang-shi

    2017-10-01

    Based on a testing method of spatial frequency response(SFR), a setup for characteristics measurements of the infrared defect tester,which can also be called electroluminescence tester(EL tester), a machine examining defects of photovoltaic (PV) panel, was built. The influences of focusing plane adjustments and infrared light box arrangements on resolution measurement of EL tester in full field of view were analyzed. For different types of EL testers, portable and fixed, testing methods and procedures were presented. Especially, a novel testing method for portable EL was claimed, which could do the work well without reference background. Based on method claimed and setup built, the resolutions of different types of EL testers were obtained and stable results were achieved. This setup is portable designed to meet online measurements requirements of PV industry.

  12. Inter-rater reliability of an observation-based ergonomics assessment checklist for office workers.

    Science.gov (United States)

    Pereira, Michelle Jessica; Straker, Leon Melville; Comans, Tracy Anne; Johnston, Venerina

    2016-12-01

    To establish the inter-rater reliability of an observation-based ergonomics assessment checklist for computer workers. A 37-item (38-item if a laptop was part of the workstation) comprehensive observational ergonomics assessment checklist comparable to government guidelines and up to date with empirical evidence was developed. Two trained practitioners assessed full-time office workers performing their usual computer-based work and evaluated the suitability of workstations used. Practitioners assessed each participant consecutively. The order of assessors was randomised, and the second assessor was blinded to the findings of the first. Unadjusted kappa coefficients between the raters were obtained for the overall checklist and subsections that were formed from question-items relevant to specific workstation equipment. Twenty-seven office workers were recruited. The inter-rater reliability between two trained practitioners achieved moderate to good reliability for all except one checklist component. This checklist has mostly moderate to good reliability between two trained practitioners. Practitioner Summary: This reliable ergonomics assessment checklist for computer workers was designed using accessible government guidelines and supplemented with up-to-date evidence. Employers in Queensland (Australia) can fulfil legislative requirements by using this reliable checklist to identify and subsequently address potential risk factors for work-related injury to provide a safe working environment.

  13. Inter-observer reliability of DSM-5 substance use disorders.

    Science.gov (United States)

    Denis, Cécile M; Gelernter, Joel; Hart, Amy B; Kranzler, Henry R

    2015-08-01

    Although studies have examined the impact of changes made in DSM-5 on the estimated prevalence of substance use disorder (SUD) diagnoses, there is limited evidence concerning the reliability of DSM-5 SUDs. We evaluated the inter-observer reliability of four DSM-5 SUDs in a sample in which we had previously evaluated the reliability of DSM-IV diagnoses, allowing us to compare the two systems. Two different interviewers each assessed 173 subjects over a 2-week period using the Semi-Structured Assessment for Drug Dependence and Alcoholism (SSADDA). Using the percent agreement and kappa (κ) coefficient, we examined the reliability of DSM-5 lifetime alcohol, opioid, cocaine, and cannabis use disorders, which we compared to that of SSADDA-derived DSM-IV SUD diagnoses. We also assessed the effect of additional lifetime SUD and lifetime mood or anxiety disorder diagnoses on the reliability of the DSM-5 SUD diagnoses. Reliability was good to excellent for the four disorders, with κ values ranging from 0.65 to 0.94. Agreement was consistently lower for SUDs of mild severity than for moderate or severe disorders. DSM-5 SUD diagnoses showed greater reliability than DSM-IV diagnoses of abuse or dependence or dependence only. Co-occurring SUD and lifetime mood or anxiety disorders exerted a modest effect on the reliability of the DSM-5 SUD diagnoses. For alcohol, opioid, cocaine and cannabis use disorders, DSM-5 criteria and diagnoses are at least as reliable as those of DSM-IV. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  14. Inter-Observer Reliability of DSM-5 Substance Use Disorders*

    Science.gov (United States)

    Denis, Cécile M.; Gelernter, Joel; Hart, Amy B.; Kranzler, Henry R.

    2015-01-01

    Aims Although studies have examined the impact of changes made in DSM-5 on the estimated prevalence of substance use disorder (SUD) diagnoses, there is limited evidence of the reliability of DSM-5 SUDs. We evaluated the inter-observer reliability of four DSM-5 SUDs in a sample in which we had previously evaluated the reliability of DSM-IV diagnoses, allowing us to compare the two systems. Methods Two different interviewers each assessed 173 subjects over a 2-week period using the Semi-Structured Assessment for Drug Dependence and Alcoholism (SSADDA). Using the percent agreement and kappa (κ) coefficient, we examined the reliability of DSM-5 lifetime alcohol, opioid, cocaine, and cannabis use disorders, which we compared to that of SSADDA-derived DSM-IV SUD diagnoses. We also assessed the effect of additional lifetime SUD and lifetime mood or anxiety disorder diagnoses on the reliability of the DSM-5 SUD diagnoses. Results Reliability was good to excellent for the four disorders, with κ values ranging from 0.65 to 0.94. Agreement was consistently lower for SUDs of mild severity than for moderate or severe disorders. DSM-5 SUD diagnoses showed greater reliability than DSM-IV diagnoses of abuse or dependence or dependence only. Co-occurring SUD and lifetime mood or anxiety disorders exerted a modest effect on the reliability of the DSM-5 SUD diagnoses. Conclusions For alcohol, opioid, cocaine and cannabis use disorders, DSM-5 criteria and diagnoses are at least as reliable as those of DSM-IV. PMID:26048641

  15. Improved radiograph measurement inter-observer reliability by use of statistical shape models

    Energy Technology Data Exchange (ETDEWEB)

    Pegg, E.C., E-mail: elise.pegg@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Mellon, S.J., E-mail: stephen.mellon@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Salmon, G. [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Alvand, A., E-mail: abtin.alvand@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Pandit, H., E-mail: hemant.pandit@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Murray, D.W., E-mail: david.murray@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Gill, H.S., E-mail: richie.gill@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom)

    2012-10-15

    Pre- and post-operative radiographs of patients undergoing joint arthroplasty are often examined for a variety of purposes including preoperative planning and patient assessment. This work examines the feasibility of using active shape models (ASM) to semi-automate measurements from post-operative radiographs for the specific case of the Oxford™ Unicompartmental Knee. Measurements of the proximal tibia and the position of the tibial tray were made using the ASM model and manually. Data were obtained by four observers and one observer took four sets of measurements to allow assessment of the inter- and intra-observer reliability, respectively. The parameters measured were the tibial tray angle, the tray overhang, the tray size, the sagittal cut position, the resection level and the tibial width. Results demonstrated improved reliability (average of 27% and 11.2% increase for intra- and inter-reliability, respectively) and equivalent accuracy (p > 0.05 for compared data values) for all of the measurements using the ASM model, with the exception of the tray overhang (p = 0.0001). Less time (15 s) was required to take measurements using the ASM model compared with manual measurements, which was significant. These encouraging results indicate that semi-automated measurement techniques could improve the reliability of radiographic measurements.

  16. Improved radiograph measurement inter-observer reliability by use of statistical shape models

    International Nuclear Information System (INIS)

    Pegg, E.C.; Mellon, S.J.; Salmon, G.; Alvand, A.; Pandit, H.; Murray, D.W.; Gill, H.S.

    2012-01-01

    Pre- and post-operative radiographs of patients undergoing joint arthroplasty are often examined for a variety of purposes including preoperative planning and patient assessment. This work examines the feasibility of using active shape models (ASM) to semi-automate measurements from post-operative radiographs for the specific case of the Oxford™ Unicompartmental Knee. Measurements of the proximal tibia and the position of the tibial tray were made using the ASM model and manually. Data were obtained by four observers and one observer took four sets of measurements to allow assessment of the inter- and intra-observer reliability, respectively. The parameters measured were the tibial tray angle, the tray overhang, the tray size, the sagittal cut position, the resection level and the tibial width. Results demonstrated improved reliability (average of 27% and 11.2% increase for intra- and inter-reliability, respectively) and equivalent accuracy (p > 0.05 for compared data values) for all of the measurements using the ASM model, with the exception of the tray overhang (p = 0.0001). Less time (15 s) was required to take measurements using the ASM model compared with manual measurements, which was significant. These encouraging results indicate that semi-automated measurement techniques could improve the reliability of radiographic measurements

  17. Test–re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females

    OpenAIRE

    Chris Beardsley; Tim Egerton; Brendon Skinner

    2016-01-01

    Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females.\\ud \\ud Method. The inter-rater reliability and test–re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart.\\ud \\ud Results. For measuring pel...

  18. Development of a second generation rolling contact fatigue tester

    Science.gov (United States)

    Deshmukh, Satyam U.

    Contact fatigue failure has been in research since the early twentieth century. The need for a second generation sliding-rolling contact fatigue tester was proposed by Gregory Dvorak and Dr. Marcellin Zahui. The first generation RCF tester was used for testing super finishing processes for gear surfaces. The second generation RCF tester was funded by the Advanced Engineering Materials lab of University of North Dakota. Verification of the second generation Rolling Contact Fatigue Tester will be discussed in this thesis including the design details, assembly and testing procedure and to discuss its different parameters. The tester will have the capability of testing hollow specimens using a bobbin eddy current testing probe. This tester will allow a wide range of experiments and is not built for one specific purpose. An eddy current device is used for detecting cracks. The loading force is applied using hydraulic cylinders and a hydraulic power unit. Before testing began, the machine was run for some time at full speed. A lot of minor problems were detected and fixed. Three specimens of AISI 8620 were tested in this tester. All tests gave results matching with some of the other well-known RCF testers. These tests were performed to evaluate mechanical limits of the tester and to evaluate the software performance of the tester.

  19. Face validity and inter-rater reliability of the Danish version of the modified-Yale Preoperative Anxiety Scale

    DEFF Research Database (Denmark)

    Skovby, Pernille; Rask, Charlotte Ulrikka; Dall, Rolf

    2014-01-01

    -YPAS to Danish cultural and linguistic conditions and to test face validity and inter-reliability in a clinical setting. Materials and methods The translation was performed in accordance with WHO guidelines. Face validity as well as linguistic difficulties of the Danish version was tested and solved in a focus...... of the m-YPAS as suitable and relevant, i.e. the face validity satisfactory. Inter-rater reliability analysis revealed that inter-observer agreement at induction 1 were good to very good (kw: 0.63–0.98) and at induction 2, the agreement was good to very good (kw: 0.72–0.96). ICC for the overall weighted...... anxiety score was in: induction 1:0.92 and induction 2: 0.92 Conclusion Standardized and validated assessment tools are needed to evaluate interventions aiming to reduce preoperative anxiety in children. The Danish m-YPAS had a satisfactory face validity and inter-reliability, based on a minor empirical...

  20. 21 CFR 870.3720 - Pacemaker electrode function tester.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker electrode function tester. 870.3720... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3720 Pacemaker electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is...

  1. RELIABILITY OF ANKLE-FOOT MORPHOLOGY, MOBILITY, STRENGTH, AND MOTOR PERFORMANCE MEASURES.

    Science.gov (United States)

    Fraser, John J; Koldenhoven, Rachel M; Saliba, Susan A; Hertel, Jay

    2017-12-01

    Assessment of foot posture, morphology, intersegmental mobility, strength and motor control of the ankle-foot complex are commonly used clinically, but measurement properties of many assessments are unclear. To determine test-retest and inter-rater reliability, standard error of measurement, and minimal detectable change of morphology, joint excursion and play, strength, and motor control of the ankle-foot complex. Reliability study. 24 healthy, recreationally-active young adults without history of ankle-foot injury were assessed by two clinicians on two occasions, three to ten days apart. Measurement properties were assessed for foot morphology (foot posture index, total and truncated length, width, arch height), joint excursion (weight-bearing dorsiflexion, rearfoot and hallux goniometry, forefoot inclinometry, 1 st metatarsal displacement) and joint play, strength (handheld dynamometry), and motor control rating during intrinsic foot muscle (IFM) exercises. Clinician order was randomized using a Latin Square. The clinicians performed independent examinations and did not confer on the findings for the duration of the study. Test-retest and inter-tester reliability and agreement was assessed using intraclass correlation coefficients (ICC 2,k ) and weighted kappa ( K w ). Test-retest reliability ICC were as follows: morphology: .80-1.00, joint excursion: .58-.97, joint play: -.67-.84, strength: .67-.92, IFM motor rating: K W -.01-.71. Inter-rater reliability ICC were as follows: morphology: .81-1.00, joint excursion: .32-.97, joint play: -1.06-1.00, strength: .53-.90, and IFM motor rating: K w .02-.56. Measures of ankle-foot posture, morphology, joint excursion, and strength demonstrated fair to excellent test-retest and inter-rater reliability. Test-retest reliability for rating of perceived difficulty and motor performance was good to excellent for short-foot, toe-spread-out, and hallux exercises and poor to fair for lesser toe extension. Joint play measures had

  2. Measurement of the Inter-Rater Reliability Rate Is Mandatory for Improving the Quality of a Medical Database: Experience with the Paulista Lung Cancer Registry.

    Science.gov (United States)

    Lauricella, Leticia L; Costa, Priscila B; Salati, Michele; Pego-Fernandes, Paulo M; Terra, Ricardo M

    2018-06-01

    Database quality measurement should be considered a mandatory step to ensure an adequate level of confidence in data used for research and quality improvement. Several metrics have been described in the literature, but no standardized approach has been established. We aimed to describe a methodological approach applied to measure the quality and inter-rater reliability of a regional multicentric thoracic surgical database (Paulista Lung Cancer Registry). Data from the first 3 years of the Paulista Lung Cancer Registry underwent an audit process with 3 metrics: completeness, consistency, and inter-rater reliability. The first 2 methods were applied to the whole data set, and the last method was calculated using 100 cases randomized for direct auditing. Inter-rater reliability was evaluated using percentage of agreement between the data collector and auditor and through calculation of Cohen's κ and intraclass correlation. The overall completeness per section ranged from 0.88 to 1.00, and the overall consistency was 0.96. Inter-rater reliability showed many variables with high disagreement (>10%). For numerical variables, intraclass correlation was a better metric than inter-rater reliability. Cohen's κ showed that most variables had moderate to substantial agreement. The methodological approach applied to the Paulista Lung Cancer Registry showed that completeness and consistency metrics did not sufficiently reflect the real quality status of a database. The inter-rater reliability associated with κ and intraclass correlation was a better quality metric than completeness and consistency metrics because it could determine the reliability of specific variables used in research or benchmark reports. This report can be a paradigm for future studies of data quality measurement. Copyright © 2018 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Simulated patient training: Using inter-rater reliability to evaluate simulated patient consistency in nursing education.

    Science.gov (United States)

    MacLean, Sharon; Geddes, Fiona; Kelly, Michelle; Della, Phillip

    2018-03-01

    Simulated patients (SPs) are frequently used for training nursing students in communication skills. An acknowledged benefit of using SPs is the opportunity to provide a standardized approach by which participants can demonstrate and develop communication skills. However, relatively little evidence is available on how to best facilitate and evaluate the reliability and accuracy of SPs' performances. The aim of this study is to investigate the effectiveness of an evidenced based SP training framework to ensure standardization of SPs. The training framework was employed to improve inter-rater reliability of SPs. A quasi-experimental study was employed to assess SP post-training understanding of simulation scenario parameters using inter-rater reliability agreement indices. Two phases of data collection took place. Initially a trial phase including audio-visual (AV) recordings of two undergraduate nursing students completing a simulation scenario is rated by eight SPs using the Interpersonal Communication Assessments Scale (ICAS) and Quality of Discharge Teaching Scale (QDTS). In phase 2, eight SP raters and four nursing faculty raters independently evaluated students' (N=42) communication practices using the QDTS. Intraclass correlation coefficients (ICC) were >0.80 for both stages of the study in clinical communication skills. The results support the premise that if trained appropriately, SPs have a high degree of reliability and validity to both facilitate and evaluate student performance in nurse education. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  4. Reliability of McConnell's classification of patellar orientation in symptomatic and asymptomatic subjects.

    Science.gov (United States)

    Watson, C J; Propps, M; Galt, W; Redding, A; Dobbs, D

    1999-07-01

    Test-retest reliability study with blinded testers. To determine the intratester reliability of the McConnell classification system and to determine whether the intertester reliability of this system would be improved by one-on-one training of the testers, increasing the variability and numbers of subjects, blinding the testers to the absence or presence of patellofemoral pain syndrome, and adhering to the McConnell classification system as it is taught in the "McConnell Patellofemoral Treatment Plan" continuing education course. The McConnell classification system is currently used by physical therapy clinicians to quantify static patellar orientation. The measurements generated from this system purportedly guide the therapist in the application of patellofemoral tape and in assessment of the efficacy of treatment interventions on changing patellar orientation. Fifty-six subjects (age range, 21-65 years) provided a total of 101 knees for assessment. Seventy-six knees did not produce symptoms. A researcher who did not participate in the measuring process determined that 17 subjects had patellofemoral pain syndrome in 25 knees. Two testers concurrently measured static patellar orientation (anterior/posterior and medial/lateral tilt, medial/lateral glide, and patellar rotation) on subjects, using the McConnell classification system. Repeat measures were performed 3-7 days later. A kappa (kappa) statistic was used to assess the degree of agreement within each tester and between testers. The kappa coefficients for intratester reliability varied from -0.06 to 0.35. Intertester reliability ranged from -0.03 to 0.19. The McConnell classification system, in its current form, does not appear to be very reliable. Intratester reliability ranged from poor to fair, and intertester reliability was poor to slight. This system should not be used as a measurement tool or as a basis for treatment decisions.

  5. Translation, adaptation and inter-rater reliability of the administration manual for the Fugl-Meyer assessment.

    Science.gov (United States)

    Michaelsen, Stella M; Rocha, André S; Knabben, Rodrigo J; Rodrigues, Luciano P; Fernandes, Claudia G C

    2011-01-01

    Recently, the reliability of the Brazilian version of the Fugl-Meyer Assessment (FMA) was assessed through the scoring given according to observations made by a single evaluator who applied the test. When different raters apply the scale, the reliability may depend on the interpretation given to the assessment sheet. In such cases, a clear administration manual is essential for ensuring homogeneity of application. To translate and adapt the French Canadian version of the FMA administration manual into Brazilian Portuguese and to evaluate the inter-rater reliability when different evaluators apply the FMA on the basis of the information contained in the manual. Eighteen adults (59±10 years) with chronic hemiparesis (38±35 months after a stroke) took part in this study. Eight patients participated in the first part of the study and 10 in the second part. Based on analyzing the results from part 1, an adapted version was developed, in which information and photos were added to illustrate the positions of the patient and evaluator. The inter-rater reliability was assessed using the intraclass correlation coefficient (ICC). The reliability of the FMA based on the adapted version of the manual was excellent for the total motor scores for the upper limbs (ICC=0.98) and lower limbs (ICC=0.90), as well as for movement sense (ICC=0.98) and upper and lower-limb passive range of motion (ICC=0.84 and 0.90, respectively). The reliability was moderate for tactile sensitivity (0.75). The joint pain assessment presented low reliability. The results showed that, except for pain assessment, application of the FMA based on the adapted version of the application manual for Brazilian Portuguese presented adequate inter-rater reliability.

  6. THE INTRA- AND INTER-RATER RELIABILITY OF THE SOCCER INJURY MOVEMENT SCREEN (SIMS).

    Science.gov (United States)

    McCunn, Robert; Aus der Fünten, Karen; Govus, Andrew; Julian, Ross; Schimpchen, Jan; Meyer, Tim

    2017-02-01

    The growing volume of movement screening research reveals a belief among practitioners and researchers alike that movement quality may have an association with injury risk. However, existing movement screening tools have not considered the sport-specific movement and injury patterns relevant to soccer. The present study introduces the Soccer Injury Movement Screen (SIMS), which has been designed specifically for use within soccer. Furthermore, the purpose of the present study was to assess the intra- and inter-rater reliability of the SIMS and determine its suitability for use in further research. The study utilized a test-retest design to discern reliablility. Twenty-five (11 males, 14 females) healthy, recreationally active university students (age 25.5 ± 4.0 years, height 171 ± 9 cm, weight 64.7 ± 12.6 kg) agreed to participate. The SIMS contains five sub-tests: the anterior reach, single-leg deadlift, in-line lunge, single-leg hop for distance and tuck jump. Each movement was scored out of 10 points and summed to produce a composite score out of 50. The anterior reach and single-leg hop for distance were scored in real-time while the remaining tests were filmed and scored retrospectively. Three raters conducted the SIMS with each participant on three occasions separated by an average of three and a half days (minimum one day, maximum seven days). Rater 1 re-scored the filmed movements for all participants on all occasions six months later to establish the 'pure' intra-rater (intra-occasion) reliability for those movements. Intraclass correlation coefficient (ICC) values for intra- and inter-rater composite score reliability ranged from 0.66-0.72 and 0.79-0.86 respectively. Weighted kappa values representing the intra- and inter-rater reliability of the individual sub-tests ranged from 0.35-0.91 indicating fair to almost perfect agreement. Establishing the reliability of the SIMS is a prerequisite for further research seeking to investigate

  7. Intra and Inter-Rater Reliability of Screening for Movement Impairments: Movement Control Tests from The Foundation Matrix

    Science.gov (United States)

    Mischiati, Carolina R.; Comerford, Mark; Gosford, Emma; Swart, Jacqueline; Ewings, Sean; Botha, Nadine; Stokes, Maria; Mottram, Sarah L.

    2015-01-01

    Pre-season screening is well established within the sporting arena, and aims to enhance performance and reduce injury risk. With the increasing need to identify potential injury with greater accuracy, a new risk assessment process has been produced; The Performance Matrix (battery of movement control tests). As with any new method of objective testing, it is fundamental to establish whether the same results can be reproduced between examiners and by the same examiner on consecutive occasions. This study aimed to determine the intra-rater test re-test and inter-rater reliability of tests from a component of The Performance Matrix, The Foundation Matrix. Twenty participants were screened by two experienced musculoskeletal therapists using nine tests to assess the ability to control movement during specific tasks. Movement evaluation criteria for each test were rated as pass or fail. The therapists observed participants real-time and tests were recorded on video to enable repeated ratings four months later to examine intra-rater reliability (videos rated two weeks apart). Overall test percentage agreement was 87% for inter-rater reliability; 98% Rater 1, 94% Rater 2 for test re-test reliability; and 75% for real-time versus video. Intraclass-correlation coefficients (ICCs) were excellent between raters (0.81) and within raters (Rater 1, 0.96; Rater 2, 0.88) but poor for real-time versus video (0.23). Reliability for individual components of each test was more variable: inter-rater, 68-100%; intra-rater, 88-100% Rater 1, 75-100% Rater 2; and real-time versus video 31-100%. Cohen’s Kappa values for inter-rater reliability were 0.0-1.0; intra-rater 0.6-1.0 for Rater 1; -0.1-1.0 for Rater 2; and -0.1-1 for real-time versus video. It is concluded that both inter and intra-rater reliability of tests in The Foundation Matrix are acceptable when rated by experienced therapists. Recommendations are made for modifying some of the criteria to improve reliability where

  8. Reliability of sagittal plane hip, knee, and ankle joint angles from a single frame of video data using the GAITRite camera system.

    Science.gov (United States)

    Ross, Sandy A; Rice, Clinton; Von Behren, Kristyn; Meyer, April; Alexander, Rachel; Murfin, Scott

    2015-01-01

    The purpose of this study was to establish intra-rater, intra-session, and inter-rater, reliability of sagittal plane hip, knee, and ankle angles with and without reflective markers using the GAITRite walkway and single video camera between student physical therapists and an experienced physical therapist. This study included thirty-two healthy participants age 20-59, stratified by age and gender. Participants performed three successful walks with and without markers applied to anatomical landmarks. GAITRite software was used to digitize sagittal hip, knee, and ankle angles at two phases of gait: (1) initial contact; and (2) mid-stance. Intra-rater reliability was more consistent for the experienced physical therapist, regardless of joint or phase of gait. Intra-session reliability was variable, the experienced physical therapist showed moderate to high reliability (intra-class correlation coefficient (ICC) = 0.50-0.89) and the student physical therapist showed very poor to high reliability (ICC = 0.07-0.85). Inter-rater reliability was highest during mid-stance at the knee with markers (ICC = 0.86) and lowest during mid-stance at the hip without markers (ICC = 0.25). Reliability of a single camera system, especially at the knee joint shows promise. Depending on the specific type of reliability, error can be attributed to the testers (e.g. lack of digitization practice and marker placement), participants (e.g. loose fitting clothing) and camera systems (e.g. frame rate and resolution). However, until the camera technology can be upgraded to a higher frame rate and resolution, and the software can be linked to the GAITRite walkway, the clinical utility for pre/post measures is limited.

  9. Microcontroller based Integrated Circuit Tester

    OpenAIRE

    Yousif Taha Yousif Elamin; Abdelrasoul Jabar Alzubaidi

    2015-01-01

    The digital integrated circuit (IC) tester is implemented by using the ATmega32 microcontroller . The microcontroller processes the inputs and outputs and displays the results on a Liquid Crystal Display (LCD). The basic function of the digital IC tester is to test a digital IC for correct logical functioning as described in the truth table and/or function table. The designed model can test digital ICs having 14 pins. Since it is programmable, any number of ICs can be tested . Thi...

  10. Inter-rater reliability of diagnostic criteria for sacroiliac joint-, disc- and facet joint pain.

    Science.gov (United States)

    van Tilburg, Cornelis W J; Groeneweg, Johannes G; Stronks, Dirk L; Huygen, Frank J P M

    2017-01-01

    Several diagnostic criteria sets are described in the literature to identify low back pain subtypes, but very little is known about the inter-rater reliability of these criteria. We conducted a study to determine the reliability of diagnostic tests that point towards SI joint-, disc- or facet joint pain. Inter-rater reliability study alongside three randomized clinical trials. Multidisciplinary pain center of general hospital. Patients aged 18 or more with medical history and physical examination suggestive of sacroiliac joint-, disc- and facet joint pain on lumbar level. Making use of nowadays most common used diagnostic criteria, a physical examination is taken independently by three physicians (two pain physicians and one orthopedic surgeon). Inter-rater reliability (Kappa (κ) measure of agreement) and significance (p) between raters are presented. Strengths of agreement, indicated with κ values above 0,20, are presented in order of agreement. One hundred patients were included. None of the parameters from the physical investigation had κ values of more than 0.21 (fair) in all pairs of raters. Between two raters (C and D), there was an almost perfect agreement on three parameters, more specifically ``Abnormal sensory and motor examination, hyperactive or diminished reflexes'', ``Sitting exam shows no reflex, motor or sensory signs in the legs'' and ``Straight leg raising (Laségue) negative between 30 and 70 degrees of flexion''. The ``Drop test positive'' parameters had moderate strength of agreement between raters A and D and fair strength between raters A and B. The ``Digital interspinous pressure test positive'' had moderate strength of agreement between raters C and D and fair strength of agreement between raters A and B as well as raters B and C. Three other parameters had a fair strength of agreement between two raters, all other parameters had a slight or poor strength of agreement. Inter-rater reliability, confidence intervals and significance of

  11. Test-retest, inter-assessor and intra-assessor reliability of the modified Touwen examination

    NARCIS (Netherlands)

    Peters, Lieke H. J.; Maathuis, Karel G. B.; Kouw, Eva; Hamming, Marjolein; Hadders-Algra, Mijna

    Interest in the Touwen examination (1979) for the assessment of minor neurological dysfunction (MND) is growing. However, information on psychometric properties of this assessment is scarce. Therefore the present study aimed at assessing the test's test-retest, inter- and intra-assessor reliability.

  12. Development and inter-rater reliability of a standardized verbal instruction manual for the Chinese Geriatric Depression Scale-short form.

    Science.gov (United States)

    Wong, M T P; Ho, T P; Ho, M Y; Yu, C S; Wong, Y H; Lee, S Y

    2002-05-01

    The Geriatric Depression Scale (GDS) is a common screening tool for elderly depression in Hong Kong. This study aimed at (1) developing a standardized manual for the verbal administration and scoring of the GDS-SF, and (2) comparing the inter-rater reliability between the standardized and non-standardized verbal administration of GDS-SF. Two studies were reported. In Study 1, the process of developing the manual was described. In Study 2, we compared the inter-rater reliabilities of GDS-SF scores using the standardized verbal instructions and the traditional non-standardized administration. Results of Study 2 indicated that the standardized procedure in verbal administration and scoring improved the inter-rater reliabilities of GDS-SF. Copyright 2002 John Wiley & Sons, Ltd.

  13. Sandia's severe human body Electrostatic Discharge Tester (SSET)

    International Nuclear Information System (INIS)

    Barnum, J.R.

    1991-01-01

    This paper reports that the Electromagnetic Testing Division at Sandia National Laboratories (SNL) has developed a simulator to replicate a severe human body electrostatic discharge event. This simulator is referred to as Sandia's Severe Human Body Electrostatic Discharge Tester (SSET). The SSET is configured as a coaxial transmission line, which allows control of parasitic inductance and capacitance to achieve the desired waveform signature, and operates reliably at voltages up to 35 kV. It is constructed from off-the-shelf or easily fabricated components and costs approximately $750 for materials, not including the power supply. The output is very repeatable and provides good simulation fidelity of a severe human body discharge

  14. The Outdoor MEDIA DOT: The development and inter-rater reliability of a tool designed to measure food and beverage outlets and outdoor advertising.

    Science.gov (United States)

    Poulos, Natalie S; Pasch, Keryn E

    2015-07-01

    Few studies of the food environment have collected primary data, and even fewer have reported reliability of the tool used. This study focused on the development of an innovative electronic data collection tool used to document outdoor food and beverage (FB) advertising and establishments near 43 middle and high schools in the Outdoor MEDIA Study. Tool development used GIS based mapping, an electronic data collection form on handheld devices, and an easily adaptable interface to efficiently collect primary data within the food environment. For the reliability study, two teams of data collectors documented all FB advertising and establishments within one half-mile of six middle schools. Inter-rater reliability was calculated overall and by advertisement or establishment category using percent agreement. A total of 824 advertisements (n=233), establishment advertisements (n=499), and establishments (n=92) were documented (range=8-229 per school). Overall inter-rater reliability of the developed tool ranged from 69-89% for advertisements and establishments. Results suggest that the developed tool is highly reliable and effective for documenting the outdoor FB environment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Intra- and inter-rater reliability of the Knee Society Knee Score when used by two physiotherapists in patients post total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    S. Gopal

    2010-01-01

    Full Text Available Background and Purpose: It has yet to be shown whether routine physiotherapy plays a role in the rehabilitation of patients post totalknee arthroplasty (Rajan et al 2004. Physiotherapists should be using validoutcome measures to provide evidence of the benefit of their intervention. The aim of this study was to establish the intra and inter-rater reliability of the Knee Society Knee Score, a scoring system developed by Insall et al(1989. The Knee Society Knee Score can be used to assess the integrity of theknee joint of patients undergoing total knee arthroplasty. Since the scoreinvolves clinical testing, the intra-rater reliability of the clinician should be established prior to using the scores as datain clinical research. W here multiple clinicians are involved, inter-rater reliability should also be established.Design: This was a correlation study.Subjects: A  sample of thirty patients post total knee arthroplasty attending the arthroplasty clinic at Johannesburg Hospital between six weeks and twelve months postoperatively.M ethod: Recruited patients were evaluated twice with a time interval of one hour between each assessment. Statistical A nalysis: The intra- and inter-rater reliability were estimated using Intraclass Correlation Coefficient (ICC. R esults: The intra-rater reliability showed excellent reliability (h= 0.95 for Examiner A  and good reliability (h= 0.71for Examiner B. The inter-rater reliability showed moderate reliability (h= 0.67 during test one and h= 0.66 during test two.Conclusion: The KSKS has good intra-rater reliability when tested within a period of one hour. The KSKS demonstrated moderate agreement for inter rater reliability.

  16. Inter-Rater Reliability and Validity of the Australian Football League’s Kicking and Handball Tests

    Science.gov (United States)

    Cripps, Ashley J.; Hopper, Luke S.; Joyce, Christopher

    2015-01-01

    Talent identification tests used at the Australian Football League’s National Draft Combine assess the capacities of athletes to compete at a professional level. Tests created for the National Draft Combine are also commonly used for talent identification and athlete development in development pathways. The skills tests created by the Australian Football League required players to either handball (striking the ball with the hand) or kick to a series of 6 randomly generated targets. Assessors subjectively rate each skill execution giving a 0-5 score for each disposal. This study aimed to investigate the inter-rater reliability and validity of the skills tests at an adolescent sub-elite level. Male Australian footballers were recruited from sub-elite adolescent teams (n = 121, age = 15.7 ± 0.3 years, height = 1.77 ± 0.07 m, mass = 69.17 ± 8.08 kg). The coaches (n = 7) of each team were also recruited. Inter-rater reliability was assessed using Inter-class correlations (ICC) and Limits of Agreement statistics. Both the kicking (ICC = 0.96, p handball tests (ICC = 0.89, p handball test. Key points The skill tests created by the AFL demonstrated acceptable levels of relative and absolute inter-rater reliability. Both the AFL’s skills tests are able to differentiate between athletes dominant and non-dominant limbs. However, only the kicking test could consistently differentiated between score outcomes over a range of Australian Football specific disposal distances. Both tests demonstrated poor concurrent validity, with no correlation found between coaches’ perceptions of technical skills and actual skill outcomes measured. PMID:26336356

  17. Reliability of an Automated High-Resolution Manometry Analysis Program across Expert Users, Novice Users, and Speech-Language Pathologists

    Science.gov (United States)

    Jones, Corinne A.; Hoffman, Matthew R.; Geng, Zhixian; Abdelhalim, Suzan M.; Jiang, Jack J.; McCulloch, Timothy M.

    2014-01-01

    Purpose: The purpose of this study was to investigate inter- and intrarater reliability among expert users, novice users, and speech-language pathologists with a semiautomated high-resolution manometry analysis program. We hypothesized that all users would have high intrarater reliability and high interrater reliability. Method: Three expert…

  18. Inter-tester reliability of a new diagnostic classification system for patients with non-specific low back pain

    DEFF Research Database (Denmark)

    Petersen, Tom Erik; Olsen, Steen; Laslett, Mark

    2004-01-01

    Most patients referred to physiotherapy with low back pain are without a precise medical diagnosis. Identification of subgroups of non-specific low back pain patients may improve clinical outcomes and research efficiency. A pathoanatomic classification system has been developed, classifying...... modest level of total agreement (39%) for the system as a whole might indicate that the utility of the system for general screening purposes is limited, compared with the utility in identification of particular syndromes. Due to low prevalence of positive findings in some of the syndromes, future work...... should focus on testing reliability on a larger sample of patients, and testing of validity and feasibility of the system....

  19. Chest computed tomography-based scoring of thoracic sarcoidosis: Inter-rater reliability of CT abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Heuvel, D.A.V. den; Es, H.W. van; Heesewijk, J.P. van; Spee, M. [St. Antonius Hospital Nieuwegein, Department of Radiology, Nieuwegein (Netherlands); Jong, P.A. de [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Zanen, P.; Grutters, J.C. [University Medical Center Utrecht, Division Heart and Lungs, Utrecht (Netherlands); St. Antonius Hospital Nieuwegein, Center of Interstitial Lung Diseases, Department of Pulmonology, Nieuwegein (Netherlands)

    2015-09-15

    To determine inter-rater reliability of sarcoidosis-related computed tomography (CT) findings that can be used for scoring of thoracic sarcoidosis. CT images of 51 patients with sarcoidosis were scored by five chest radiologists for various abnormal CT findings (22 in total) encountered in thoracic sarcoidosis. Using intra-class correlation coefficient (ICC) analysis, inter-rater reliability was analysed and reported according to the Guidelines for Reporting Reliability and Agreement Studies (GRRAS) criteria. A pre-specified sub-analysis was performed to investigate the effect of training. Scoring was trained in a distinct set of 15 scans in which all abnormal CT findings were represented. Median age of the 51 patients (36 men, 70 %) was 43 years (range 26 - 64 years). All radiographic stages were present in this group. ICC ranged from 0.91 for honeycombing to 0.11 for nodular margin (sharp versus ill-defined). The ICC was above 0.60 in 13 of the 22 abnormal findings. Sub-analysis for the best-trained observers demonstrated an ICC improvement for all abnormal findings and values above 0.60 for 16 of the 22 abnormalities. In our cohort, reliability between raters was acceptable for 16 thoracic sarcoidosis-related abnormal CT findings. (orig.)

  20. Chest computed tomography-based scoring of thoracic sarcoidosis: Inter-rater reliability of CT abnormalities

    International Nuclear Information System (INIS)

    Heuvel, D.A.V. den; Es, H.W. van; Heesewijk, J.P. van; Spee, M.; Jong, P.A. de; Zanen, P.; Grutters, J.C.

    2015-01-01

    To determine inter-rater reliability of sarcoidosis-related computed tomography (CT) findings that can be used for scoring of thoracic sarcoidosis. CT images of 51 patients with sarcoidosis were scored by five chest radiologists for various abnormal CT findings (22 in total) encountered in thoracic sarcoidosis. Using intra-class correlation coefficient (ICC) analysis, inter-rater reliability was analysed and reported according to the Guidelines for Reporting Reliability and Agreement Studies (GRRAS) criteria. A pre-specified sub-analysis was performed to investigate the effect of training. Scoring was trained in a distinct set of 15 scans in which all abnormal CT findings were represented. Median age of the 51 patients (36 men, 70 %) was 43 years (range 26 - 64 years). All radiographic stages were present in this group. ICC ranged from 0.91 for honeycombing to 0.11 for nodular margin (sharp versus ill-defined). The ICC was above 0.60 in 13 of the 22 abnormal findings. Sub-analysis for the best-trained observers demonstrated an ICC improvement for all abnormal findings and values above 0.60 for 16 of the 22 abnormalities. In our cohort, reliability between raters was acceptable for 16 thoracic sarcoidosis-related abnormal CT findings. (orig.)

  1. Computerized back postural assessment in physiotherapy practice: Intra-rater and inter-rater reliability of the MIDAS system.

    Science.gov (United States)

    McAlpine, R T; Bettany-Saltikov, J A; Warren, J G

    2009-01-01

    Assessment of spinal posture during physiotherapy practice is routine, yet few objective measures exist to this end. The Middlesbrough Integrated Digital Assessment System (MIDAS) is a low cost portable system able to record 3D information on posture. The purpose of this study was to assess both the intra-rater and inter-rater reliability of the MIDAS system. Twenty-five healthy subjects were recruited. A repeated measures design was used to record fifteen pre-palpated landmarks on the back of each subject. To limit the sources of variability, the principal researcher palpated the landmarks for each subject. Each of three raters took two measurements on each subject in a standardized upright posture. X (medio-lateral), Y (antero-posterior) and Z (height) landmark positions were recorded via a computer interface. Both intra-rater agreement (mean ICCs - rater 1 r=0.970, rater 2 r=0.965 and rater 3 r=0.965, pMIDAS demonstrated both high inter-rater and intra-rater reliability and provides an objective method for the assessment of posture in physiotherapy practice.

  2. Penetration Tester's Open Source Toolkit

    CERN Document Server

    Faircloth, Jeremy

    2011-01-01

    Great commercial penetration testing tools can be very expensive and sometimes hard to use or of questionable accuracy. This book helps solve both of these problems. The open source, no-cost penetration testing tools presented do a great job and can be modified by the user for each situation. Many tools, even ones that cost thousands of dollars, do not come with any type of instruction on how and in which situations the penetration tester can best use them. Penetration Tester's Open Source Toolkit, Third Edition, expands upon existing instructions so that a professional can get the most accura

  3. Inter- and intra-operator reliability and repeatability of shear wave elastography in the liver: a study in healthy volunteers.

    Science.gov (United States)

    Hudson, John M; Milot, Laurent; Parry, Craig; Williams, Ross; Burns, Peter N

    2013-06-01

    This study assessed the reproducibility of shear wave elastography (SWE) in the liver of healthy volunteers. Intra- and inter-operator reliability and repeatability were quantified in three different liver segments in a sample of 15 subjects, scanned during four independent sessions (two scans on day 1, two scans 1 wk later) by two operators. A total of 1440 measurements were made. Reproducibility was assessed using the intra-class correlation coefficient (ICC) and a repeated measures analysis of variance. The shear wave speed was measured and used to estimate Young's modulus using the Supersonics Imagine Aixplorer. The median Young's modulus measured through the inter-costal space was 5.55 ± 0.74 kPa. The intra-operator reliability was better for same-day evaluations (ICC = 0.91) than the inter-operator reliability (ICC = 0.78). Intra-observer agreement decreased when scans were repeated on a different day. Inter-session repeatability was between 3.3% and 9.9% for intra-day repeated scans, compared with to 6.5%-12% for inter-day repeated scans. No significant difference was observed in subjects with a body mass index greater or less than 25 kg/m(2). Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  4. Assessment of disabilities in stroke patients with apraxia : Internal consistency and inter-observer reliability

    NARCIS (Netherlands)

    van Heugten, CM; Dekker, J; Deelman, BG; Stehmann-Saris, JC; Kinebanian, A

    1999-01-01

    In this paper the internal consistency and inter-observer reliability of the assessment of disabilities in stroke patients with apraxia is presented. Disabilities were assessed by means of observation of activities of daily living (ADL). The study was conducted at occupational therapy departments in

  5. Assessment of disabilities in stroke patients with apraxia: internal consistency and inter-observer reliability.

    NARCIS (Netherlands)

    Heugten, C.M. van; Dekker, J.; Deelman, B.G.; Stehmann-Saris, J.C.; Kinebanian, A.

    1999-01-01

    In this paper the internal consistency and inter-observer reliability of the assessment of disabilities in stroke patients with apraxia is presented. Disabilities were assessed by means of observation of activities of daily living (ADL). The study was conducted at occupational therapy departments in

  6. IRR (Inter-Rater Reliability) of a COP (Classroom Observation Protocol)--A Critical Appraisal

    Science.gov (United States)

    Rui, Ning; Feldman, Jill M.

    2012-01-01

    Notwithstanding broad utility of COPs (classroom observation protocols), there has been limited documentation of the psychometric properties of even the most popular COPs. This study attempted to fill this void by closely examining the item and domain-level IRR (inter-rater reliability) of a COP that was used in a federally funded striving readers…

  7. 7 CFR 801.4 - Tolerances for dockage testers.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Tolerances for dockage testers. 801.4 Section 801.4 Agriculture Regulations of the Department of Agriculture (Continued) GRAIN INSPECTION, PACKERS AND STOCKYARD... FOR GRAIN INSPECTION EQUIPMENT § 801.4 Tolerances for dockage testers. The maintenance tolerances for...

  8. The inter-rater reliability and prognostic value of coma scales in Nepali children with acute encephalitis syndrome.

    Science.gov (United States)

    Ray, Stephen; Rayamajhi, Ajit; Bonnett, Laura J; Solomon, Tom; Kneen, Rachel; Griffiths, Michael J

    2018-02-01

    Background Acute encephalitis syndrome (AES) is a common cause of coma in Nepali children. The Glasgow coma scale (GCS) is used to assess the level of coma in these patients and predict outcome. Alternative coma scales may have better inter-rater reliability and prognostic value in encephalitis in Nepali children, but this has not been studied. The Adelaide coma scale (ACS), Blantyre coma scale (BCS) and the Alert, Verbal, Pain, Unresponsive scale (AVPU) are alternatives to the GCS which can be used. Methods Children aged 1-14 years who presented to Kanti Children's Hospital, Kathmandu with AES between September 2010 and November 2011 were recruited. All four coma scales (GCS, ACS, BCS and AVPU) were applied on admission, 48 h later and on discharge. Inter-rater reliability (unweighted kappa) was measured for each. Correlation and agreement between total coma score and outcome (Liverpool outcome score) was measured by Spearman's rank and Bland-Altman plot. The prognostic value of coma scales alone and in combination with physiological variables was investigated in a subgroup (n = 22). A multivariable logistic regression model was fitted by backward stepwise. Results Fifty children were recruited. Inter-rater reliability using the variables scales was fair to moderate. However, the scales poorly predicted clinical outcome. Combining the scales with physiological parameters such as systolic blood pressure improved outcome prediction. Conclusion This is the first study to compare four coma scales in Nepali children with AES. The scales exhibited fair to moderate inter-rater reliability. However, the study is inadequately powered to answer the question on the relationship between coma scales and outcome. Further larger studies are required.

  9. The Reliability of Isometer 2 Device in Measuring of Cervical Flexor and Extensor Muscles Strength

    Directory of Open Access Journals (Sweden)

    Asghar Reza Soltan-Zadeh

    2006-07-01

    Full Text Available Objective: The strength of a group of muscles can be measured by muscle strength test, employing a force measuring instrument. In order to monitor the effectiveness of a therapeutic or training programs we need a reliable technique which is also accurate in repeated measurements. The purpose of this study was to examine the reliability of an isometric neck muscle force measurement device.  Materials & Methods: Thirty seven healthy non athlete subjects (18 males and 19 females, aged 18-25 participated in this analytical study. The maximal isometric contractions of the neck extensor and flexor muscles were measured in different times and different days and by two different testers. A new sensitive “load cell” was applied to our previously designed neck muscle force measurement apparatus. Results: The results of the inter-trail, test retest, and inter rater reliability (0.86 < ICC < 0.98 , 2.2< Sw <5.1 N indicated that the neck muscle force measurements were highly repeatable and less variable between measurements. There were no statistically significant differences in neck muscle force measurements, between times, between days and between retsters. Maximum isometric contractions were significantly higher in males than in the females (p < 0.001. Women’s neck muscle strengths were 30.8% and 46.1% of men in cervical extension and cervical flexion. Conclusion: In this study we used a new model (Isometer 2 of our previous apparatus (Isometer. The isometric strength of neck flexor and extensor muscles which was measured by Isometer 2 appeared to be a reliable and useful method for measuring the force of the neck extensor and flexor muscles.

  10. Inter-rater reliability in the classification of supraspinatus tendon tears using 3D ultrasound – a question of experience?

    Directory of Open Access Journals (Sweden)

    Giorgio Tamborrini

    2016-09-01

    Full Text Available Background: Three-dimensional (3D ultrasound of the shoulder is characterized by a comparable accuracy to two-dimensional (2D ultrasound. No studies investigating 2D versus 3D inter-rater reliability in the detection of supraspinatus tendon tears taking into account the level of experience of the raters have been carried out so far. Objectives: The aim of this study was to determine the inter-rater reliability in the analysis of 3D ultrasound image sets of the supraspinatus tendon between sonographer with different levels of experience. Patients and methods: Non-interventional, prospective, observational pilot study of 2309 images of 127 adult patients suffering from unilateral shoulder pain. 3D ultrasound image sets were scored by three raters independently. The intra-and interrater reliabilities were calculated. Results: There was an excellent intra-rater reliability of rater A in the overall classification of supraspinatus tendon tears (2D vs 3D κ = 0.892, pairwise reliability 93.81%, 3D scoring round 1 vs 3D scoring round 2 κ = 0.875, pairwise reliability 92.857%. The inter-rater reliability was only moderate compared to rater B on 3D (κ = 0.497, pairwise reliability 70.95% and fair compared to rater C (κ = 0.238, pairwise reliability 42.38%. Conclusions: The reliability of 3D ultrasound of the supraspinatus tendon depends on the level of experience of the sonographer. Experience in 2D ultrasound does not seem to be sufficient for the analysis of 3D ultrasound imaging sets. Therefore, for a 3D ultrasound analysis new diagnostic criteria have to be established and taught even to experienced 2D sonographers to improve reproducibility.

  11. Inter-rater reliability of healthcare professional skills' portfolio assessments: The Andalusian Agency for Healthcare Quality model

    Directory of Open Access Journals (Sweden)

    Antonio Almuedo-Paz

    2014-07-01

    Full Text Available This study aims to determine the reliability of assessment criteria used for a portfolio at the Andalusian Agency for Healthcare Quality (ACSA. Data: all competences certification processes, regardless of their discipline. Period: 2010-2011. Three types of tests are used: 368 certificates, 17,895 reports and 22,642 clinical practice reports (N = 3,010 candidates. The tests were evaluated in pairs by the ACSA team of raters using two categories: valid and invalid. Results: The percentage agreement in assessments of certificates was 89,9%, while for the reports of clinical practice was 85,1 % and for clinical practice reports was 81,7%. The inter-rater agreement coefficients (kappa ranged from 0,468 to 0,711. Discussion: The results of this study show that the inter-rater reliability of assessments varies from fair to good. Compared with other similar studies, the results put the reliability of the model in a comfortable position. Among the improvements incorporated, progressive automation of evaluations must be highlighted.

  12. Small-Bolt Torque-Tension Tester

    Science.gov (United States)

    Posey, Alan J.

    2009-01-01

    The device described here measures the torque-tension relationship for fasteners as small as #0. The small-bolt tester consists of a plate of high-strength steel into which three miniature load cells are recessed. The depth of the recess is sized so that the three load cells can be shimmed, the optimum height depending upon the test hardware. The three miniature load cells are arranged in an equilateral triangular configuration with the test bolt aligned with the centroid of the three. This is a kinematic arrangement.

  13. Ultrasound assessment for grading structural tendon changes in supraspinatus tendinopathy: an inter-rater reliability study

    DEFF Research Database (Denmark)

    Ingwersen, Kim Gordon; Hjarbæk, John; Eshøj, Henrik

    2016-01-01

    Aim To evaluate the inter-rater reliability of measuring structural changes in the tendon of patients, clinically diagnosed with supraspinatus tendinopathy (cases) and healthy participants (controls), on ultrasound (US) images captured by standardised procedures. Methods A total of 40 participant...

  14. Inter-rater reliability of a modified version of Delitto et al.’s classification-based system for low back pain : a pilot study

    NARCIS (Netherlands)

    Apeldoorn, Adri T.; van Helvoirt, Hans; Ostelo, Raymond W.; Meihuizen, Hanneke; Kamper, Steven J.; van Tulder, Maurits W.; de Vet, Henrica C W

    2016-01-01

    Study design:: Observational inter-rater reliability study. Objectives: To examine: (1) the inter-rater reliability of a modified version of Delitto et al.’s classification-based algorithm for patients with low back pain; (2) the influence of different levels of familiarity with the system; and (3)

  15. Corrosive environment tester for filter media

    International Nuclear Information System (INIS)

    Petit, G.S.; Weber, C.W.; Keinberger, C.A.; Rivers, R.D.

    1977-02-01

    Two continuous dynamic systems have been designed and fabricated for testing filter media in humid, corrosive environments--one for fluorine or fluoride exposures, and the other for nitrogen dioxide exposures. The tester using fluorine or fluoride atmospheres was constructed of nickel and the one using nitrogen dioxide was fabricated of stainless steel. Other corrosive gases could be used with the appropriate choice of system. For example, chlorine or hydrogen chloride could be used in the system fabricated of nickel, and sulfur dioxides or ammonia could be used in the stainless steel testing apparatus. Each tester is comprised of four equivalent dynamic systems designed for diluting a corrosive reagent with dry air, then with humidified air to provide a humid-corrosive environment for filter media testing. Auxiliary equipment includes a water injection system, corrosive reagent supply systems, and an automatic pressure differential (ΔP) monitoring and recording system. The testers are relatively maintenance-free and have operated continuously for periods as long as 96 h without requiring any attention, during total exposures of materials exceeding 600 h

  16. Inter-observer and inter-examination variability of manual vertebral bone attenuation measurements on computed tomography

    International Nuclear Information System (INIS)

    Pompe, Esther; Lammers, Jan-Willem J.; Jong, Pim A. de; Jong, Werner U. de; Takx, Richard A.P.; Eikendal, Anouk L.M.; Willemink, Martin J.; Mohamed Hoesein, Firdaus A.A.; Oudkerk, Matthijs; Budde, Ricardo P.J.

    2016-01-01

    To determine inter-observer and inter-examination variability of manual attenuation measurements of the vertebrae in low-dose unenhanced chest computed tomography (CT). Three hundred and sixty-seven lung cancer screening trial participants who underwent baseline and repeat unenhanced low-dose CT after 3 months because of an indeterminate lung nodule were included. The CT attenuation value of the first lumbar vertebrae (L1) was measured in all CTs by one observer to obtain inter-examination reliability. Six observers performed measurements in 100 randomly selected CTs to determine agreement with limits of agreement and Bland-Altman plots and reliability with intraclass correlation coefficients (ICCs). Reclassification analyses were performed using a threshold of 110 HU to define osteoporosis. Inter-examination reliability was excellent with an ICC of 0.92 (p < 0.001). Inter-examination limits of agreement ranged from -26 to 28 HU with a mean difference of 1 ± 14 HU. Inter-observer reliability ICCs ranged from 0.70 to 0.91. Inter-examination variability led to 11.2 % reclassification of participants and inter-observer variability led to 22.1 % reclassification. Vertebral attenuation values can be manually quantified with good to excellent inter-examination and inter-observer reliability on unenhanced low-dose chest CT. This information is valuable for early detection of osteoporosis on low-dose chest CT. (orig.)

  17. INTER-RATER RELIABILITY FOR MOVEMENT PATTERN ANALYSIS (MPA: MEASURING PATTERNING OF BEHAVIORS VERSUS DISCRETE BEHAVIOR COUNTS AS INDICATORS OF DECISION-MAKING STYLE

    Directory of Open Access Journals (Sweden)

    Brenda L Connors

    2014-06-01

    Full Text Available The unique yield of collecting observational data on human movement has received increasing attention in a number of domains, including the study of decision-making style. As such, interest has grown in the nuances of core methodological issues, including the best ways of assessing inter-rater reliability. In this paper we focus on one key topic – the distinction between establishing reliability for the patterning of behaviors as opposed to the computation of raw counts – and suggest that reliability for each be compared empirically rather than determined a priori. We illustrate by assessing inter-rater reliability for key outcome measures derived from Movement Pattern Analysis (MPA, an observational methodology that records body movements as indicators of decision-making style with demonstrated predictive validity. While reliability ranged from moderate to good for raw counts of behaviors reflecting each of two Overall Factors generated within MPA (Assertion and Perspective, inter-rater reliability for patterning (proportional indicators of each factor was significantly higher and excellent (ICC = .89. Furthermore, patterning, as compared to raw counts, provided better prediction of observable decision-making process assessed in the laboratory. These analyses support the utility of using an empirical approach to inform the consideration of measuring discrete behavioral counts versus patterning of behaviors when determining inter-rater reliability of observable behavior. They also speak to the substantial reliability that may be achieved via application of theoretically grounded observational systems such as MPA that reveal thinking and action motivations via visible movement patterns.

  18. FPGA-based Bit-Error-Rate Tester for SEU-hardened Optical Links

    CERN Document Server

    Detraz, S; Moreira, P; Papadopoulos, S; Papakonstantinou, I; Seif El Nasr, S; Sigaud, C; Soos, C; Stejskal, P; Troska, J; Versmissen, H

    2009-01-01

    The next generation of optical links for future High-Energy Physics experiments will require components qualified for use in radiation-hard environments. To cope with radiation induced single-event upsets, the physical layer protocol will include Forward Error Correction (FEC). Bit-Error-Rate (BER) testing is a widely used method to characterize digital transmission systems. In order to measure the BER with and without the proposed FEC, simultaneously on several devices, a multi-channel BER tester has been developed. This paper describes the architecture of the tester, its implementation in a Xilinx Virtex-5 FPGA device and discusses the experimental results.

  19. Intra-rater and inter-rater reliability of the standardized ultrasound protocol for assessing subacromial structures

    DEFF Research Database (Denmark)

    Hougs Kjær, Birgitte; Ellegaard, Karen; Wieland, Ina

    2017-01-01

    BACKGROUND: US-examinations related to shoulder impingement (SI) often vary due to methodological differences, examiner positions, transducers, and recording parameters. Reliable US protocols for examination of different structures related to shoulder impingement are therefore needed. OBJECTIVES...... of the supraspinatus tendon (SUPRA) and subacromial subdeltoid (SASD) bursa in two imaging positions, and the acromial humeral distance (AHD) in one position. Additionally, agreement on dynamic impingement (DI) examination was performed. The intra- and inter-rater reliability was carried out on the same day...

  20. Inter comparison of REPAS and APSRA methodologies for passive system reliability analysis

    International Nuclear Information System (INIS)

    Solanki, R.B.; Krishnamurthy, P.R.; Singh, Suneet; Varde, P.V.; Verma, A.K.

    2014-01-01

    The increasing use of passive systems in the innovative nuclear reactors puts demand on the estimation of the reliability assessment of these passive systems. The passive systems operate on the driving forces such as natural circulation, gravity, internal stored energy etc. which are moderately weaker than that of active components. Hence, phenomenological failures (virtual components) are equally important as that of equipment failures (real components) in the evaluation of passive systems reliability. The contribution of the mechanical components to the passive system reliability can be evaluated in a classical way using the available component reliability database and well known methods. On the other hand, different methods are required to evaluate the reliability of processes like thermohydraulics due to lack of adequate failure data. The research is ongoing worldwide on the reliability assessment of the passive systems and their integration into PSA, however consensus is not reached. Two of the most widely used methods are Reliability Evaluation of Passive Systems (REPAS) and Assessment of Passive System Reliability (APSRA). Both these methods characterize the uncertainties involved in the design and process parameters governing the function of the passive system. However, these methods differ in the quantification of passive system reliability. Inter comparison among different available methods provides useful insights into the strength and weakness of different methods. This paper highlights the results of the thermal hydraulic analysis of a typical passive isolation condenser system carried out using RELAP mode 3.2 computer code applying REPAS and APSRA methodologies. The failure surface is established for the passive system under consideration and system reliability has also been evaluated using these methods. Challenges involved in passive system reliabilities are identified, which require further attention in order to overcome the shortcomings of these

  1. 24 CFR 125.107 - Testers.

    Science.gov (United States)

    2010-04-01

    ... perjury. (b) Testers must receive training or be experienced in testing procedures and techniques. (c...; (3) Have had any employment or other affiliation, within one year, with the person or organization to...

  2. Evaluation of disintegration properties of orally rapidly disintegrating tablets using a novel disintegration tester.

    Science.gov (United States)

    Kondo, Keita; Niwa, Toshiyuki; Danjo, Kazumi

    2012-01-01

    This report describes a new disintegration tester that can determine not only the disintegration time of orally rapidly disintegrating tablets (ODT), but also the disintegration behavior and mechanism. Using the tester, the disintegration properties of the tablets prepared in a previous study were examined. The purpose of this study is to confirm the utility of the tester as an instrument for evaluating the disintegration properties of ODT and determine relations among time, behavior and mechanism of the disintegration. Results demonstrated that in vitro disintegration time in the tester is similar to that in the commercial disintegration tester for ODT and is highly correlated with oral disintegration time. Observations of disintegration process revealed that a difference in disintegration behavior between tablets compressed at 50-75 MPa and 100 MPa; the disintegration behavior of the tablets were designated immediate disintegrating type and gradual disintegrating type, respectively. The dynamic swelling profile and water absorption profile indicated that the disintegration mechanism of the tablets involved wicking action induced by swelling of the disintegrant; the disintegration time was closely related to the initial rates of swelling and water absorption. Furthermore, the mechanism of water absorption of tablets compressed at 50-75 MPa and 100 MPa shows anomalous diffusion and case-II transport, respectively. The shift in this mechanism is consistent with differences in disintegration time and behavior between the tablets. These findings suggest that information on disintegration properties obtained by our tester is useful for understanding of disintegration phenomena of ODT.

  3. Examining Design and Inter-Rater Reliability of a Rubric Measuring Research Quality across Multiple Disciplines

    Directory of Open Access Journals (Sweden)

    Marilee J. Bresciani

    2009-05-01

    Full Text Available The paper presents a rubric to help evaluate the quality of research projects. The rubric was applied in a competition across a variety of disciplines during a two-day research symposium at one institution in the southwest region of the United States of America. It was collaboratively designed by a faculty committee at the institution and was administered to 204 undergraduate, master, and doctoral oral presentations by approximately 167 different evaluators. No training or norming of the rubric was given to 147 of the evaluators prior to the competition. The findings of the inter-rater reliability analysis reveal substantial agreement among the judges, which contradicts literature describing the fact that formal norming must occur prior to seeing substantial levels of inter-rater reliability. By presenting the rubric along with the methodology used in its design and evaluation, it is hoped that others will find this to be a useful tool for evaluating documents and for teaching research methods.

  4. Inter-assessor reliability of practice based biomechanical assessment of the foot and ankle

    Directory of Open Access Journals (Sweden)

    Jarvis Hannah L

    2012-06-01

    Full Text Available Abstract Background There is no consensus on which protocols should be used to assess foot and lower limb biomechanics in clinical practice. The reliability of many assessments has been questioned by previous research. The aim of this investigation was to (i identify (through consensus what biomechanical examinations are used in clinical practice and (ii evaluate the inter-assessor reliability of some of these examinations. Methods Part1: Using a modified Delphi technique 12 podiatrists derived consensus on the biomechanical examinations used in clinical practice. Part 2: Eleven podiatrists assessed 6 participants using a subset of the assessment protocol derived in Part 1. Examinations were compared between assessors. Results Clinicians choose to estimate rather than quantitatively measure foot position and motion. Poor inter-assessor reliability was recorded for all examinations. Intra-class correlation coefficient values (ICC for relaxed calcaneal stance position were less than 0.23 and were less than 0.14 for neutral calcaneal stance position. For the examination of ankle joint dorsiflexion, ICC values suggest moderate reliability (less than 0.61. The results of a random effects ANOVA highlight that participant (up to 5.7°, assessor (up to 5.8° and random (up to 5.7° error all contribute to the total error (up to 9.5° for relaxed calcaneal stance position, up to 10.7° for the examination of ankle joint dorsiflexion. Kappa Fleiss values for categorisation of first ray position and mobility were less than 0.05 and for limb length assessment less than 0.02, indicating slight agreement. Conclusion Static biomechanical assessment of the foot, leg and lower limb is an important protocol in clinical practice, but the key examinations used to make inferences about dynamic foot function and to determine orthotic prescription are unreliable.

  5. Dall-Null tester for spaceborne applications

    Science.gov (United States)

    Wingler, R. L.

    1984-12-01

    This is a study to design a self correcting primary mirror system for a space telescope. The design is centered around a Dall-Null tester (a Foucault knife-edge tester with compensating lens). An indepth study of the theory of the Foucault test from Foucault's original publications to current work is presented. Also short comings of the diffraction approach are shown. The findings of a simple experiment showed the way to the correct explanation as to the workings of the test. Based on this new explanation, a computer program to find the error in the surface of the mirror from the irradiance pattern provided by the Dall-Null tester was developed. The computer program with a sample run is included in the appendixes A and B. The basic design of an adaptive optic system for a spaceborne application is also presented in the paper. This design has the desired quality of being able to correct the mirror while the telescope is in use. The equations being independent of wavelength allows for the design to be applied to systems working outside of the visible spectrum as well as the systems working in the visible.

  6. Comparative investigations of tablet crushing force testers

    DEFF Research Database (Denmark)

    Sonnergaard, Jørn; Jensen, C.G.; Poulsen, L.

    2005-01-01

    The performance of 16 tablet breaking force testers was evaluated in terms of accuracy, reproducibility and repeatability. Three tablet formulations with different plastic or brittle deformation mechanisms and with target breaking forces of 50, 100 and 150 N were tested. Statistically significant...... by the concept of components of variance was 5-7 % depending on the model tablet excipient. The standard deviation within testers (repeatability) was affected by the type of model formulation showing increasing variability with increasing brittleness of the compressed material. No specific effect of altering...

  7. The reliability and criterion validity of 2D video assessment of single leg squat and hop landing.

    Science.gov (United States)

    Herrington, Lee; Alenezi, Faisal; Alzhrani, Msaad; Alrayani, Hasan; Jones, Richard

    2017-06-01

    The objective was to assess the intra-tester, within and between day reliability of measurement of hip adduction (HADD) and frontal plane projection angles (FPPA) during single leg squat (SLS) and single leg landing (SLL) using 2D video and the validity of these measurements against those found during 3D motion capture. 15 healthy subjects had their SLS and SLL assessed using 3D motion capture and video analysis. Inter-tester reliability for both SLS and SLL when measuring FPPA and HADD show excellent correlations (ICC 2,1 0.97-0.99). Within and between day assessment of SLS and SLL showed good to excellent correlations for both variables (ICC 3,1 0.72-91). 2D FPPA measures were found to have good correlation with knee abduction angle in 3-D (r=0.79, p=0.008) during SLS, and also to knee abduction moment (r=0.65, p=0.009). 2D HADD showed very good correlation with 3D HADD during SLS (r=0.81, p=0.001), and a good correlation during SLL (r=0.62, p=0.013). All other associations were weak (r<0.4). This study suggests that 2D video kinematics have a reasonable association to what is being measured with 3D motion capture. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Inter-rater reliability of the Sødring Motor Evaluation of Stroke patients (SMES).

    Science.gov (United States)

    Halsaa, K E; Sødring, K M; Bjelland, E; Finsrud, K; Bautz-Holter, E

    1999-12-01

    The Sødring Motor Evaluation of Stroke patients is an instrument for physiotherapists to evaluate motor function and activities in stroke patients. The rating reflects quality as well as quantity of the patient's unassisted performance within three domains: leg, arm and gross function. The inter-rater reliability of the method was studied in a sample of 30 patients admitted to a stroke rehabilitation unit. Three therapists were involved in the study; two therapists assessed the same patient on two consecutive days in a balanced design. Cohen's weighted kappa and McNemar's test of symmetry were used as measures of item reliability, and the intraclass correlation coefficient was used to express the reliability of the sumscores. For 24 out of 32 items the weighted kappa statistic was excellent (0.75-0.98), while 7 items had a kappa statistic within the range 0.53-0.74 (fair to good). The reliability of one item was poor (0.13). The intraclass correlation coefficient for the three sumscores was 0.97, 0.91 and 0.97. We conclude that the Sødring Motor Evaluation of Stroke patients is a reliable measure of motor function in stroke patients undergoing rehabilitation.

  9. Inter-rater reliability of the evaluation of muscular chains associated with posture alterations in scoliosis

    Directory of Open Access Journals (Sweden)

    Fortin Carole

    2012-05-01

    Full Text Available Abstract Background In the Global postural re-education (GPR evaluation, posture alterations are associated with anterior or posterior muscular chain impairments. Our goal was to assess the reliability of the GPR muscular chain evaluation. Methods Design: Inter-rater reliability study. Fifty physical therapists (PTs and two experts trained in GPR assessed the standing posture from photographs of five youths with idiopathic scoliosis using a posture analysis grid with 23 posture indices (PI. The PTs and experts indicated the muscular chain associated with posture alterations. The PTs were also divided into three groups according to their experience in GPR. Experts’ results (after consensus were used to verify agreement between PTs and experts for muscular chain and posture assessments. We used Kappa coefficients (K and the percentage of agreement (%A to assess inter-rater reliability and intra-class coefficients (ICC for determining agreement between PTs and experts. Results For the muscular chain evaluation, reliability was moderate to substantial for 12 PI for the PTs (%A: 56 to 82; K: 0.42 to 0.76 and perfect for 19 PI for the experts. For posture assessment, reliability was moderate to substantial for 12 PI for the PTs (%A > 60%; K: 0.42 to 0.75 and moderate to perfect for 18 PI for the experts (%A: 80 to 100; K: 0.55 to 1.00. The agreement between PTs and experts was good for most muscular chain evaluations (18 PI; ICC: 0.82 to 0.99 and PI (19 PI; ICC: 0.78 to 1.00. Conclusions The GPR muscular chain evaluation has good reliability for most posture indices. GPR evaluation should help guide physical therapists in targeting affected muscles for treatment of abnormal posture patterns.

  10. Inter-Rater and Test-Retest (Between-Sessions) Reliability of the 4-Skills Scan for Dutch Elementary School Children

    Science.gov (United States)

    van Kernebeek, Willem G.; de Schipper, Antoine W.; Savelsbergh, Geert J. P.; Toussaint, Huub M.

    2018-01-01

    In The Netherlands, the 4-Skills Scan is an instrument for physical education teachers to assess gross motor skills of elementary school children. Little is known about its reliability. Therefore, in this study the test-retest and inter-rater reliability was determined. Respectively, 624 and 557 Dutch 6- to 12-year-old children were analyzed for…

  11. Armstrong Laboratory Space Visual Function Tester Program

    Science.gov (United States)

    Oneal, Melvin R.; Task, H. Lee; Gleason, Gerald A.

    1992-01-01

    Viewgraphs on space visual function tester program are presented. Many astronauts and cosmonauts have commented on apparent changes in their vision while on-orbit. Comments have included descriptions of earth features and objects that would suggest enhanced distance visual acuity. In contrast, some cosmonaut observations suggest a slight loss in their object discrimination during initial space flight. Astronauts have also mentioned a decreased near vision capability that did not recover to normal until return to earth. Duntley space vision experiment, USSR space vision experiments, and visual function testers are described.

  12. A comparison of damage profiling of automated tap testers on aircraft CFRP panel

    Science.gov (United States)

    Mohd Aris, K. D.; Shariff, M. F.; Abd Latif, B. R.; Mohd Haris, M. Y.; Baidzawi, I. J.

    2017-12-01

    The use of composite materials nevertheless is getting more prominent. The combination of reinforcing fibers and matrices will produce the desired strength orientation, tailorability and not to mention the complex shape that is hard to form on metallic structure. The weight percentage of composite materials used in aerospace, civil, marine etc. has increased tremendously. Since composite are stacked together, the possibility of delamination and/disbond defects are highly present either in the monolithic or sandwich structures. Tap test is the cheapest form of nondestructive test to identify the presence of this damage. However, its inconsistency and wide area of coverage can reduce its effectivity since it is carried out manually. The indigenous automated tap tester known as KETOK was used to detect the damage due to trapped voids and air pockets. The mechanism of detection is through controlling the tapping on the surface automatically at a constant rate. Another manual tap tester RD-3 from Wichitech Industries Inc. was used as reference. The acquired data was translated into damage profiling and both results were compared. The results have shown that the indigenous automated tester can profile the damage better when compared with the existing tap tester. As a conclusion, the indigenous automated tap tester has a potential to be used as an IN-SITU damage detection tool to detect delamination and disbond damage on composite panel. However, more conclusive tests need to be done in order to make the unit available to conventional users.

  13. Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines

    Directory of Open Access Journals (Sweden)

    Cameron Alyse FM

    2009-11-01

    Full Text Available Abstract Background Diagnostic ultrasound provides a method of analysing soft tissue structures of the musculoskeletal system effectively and reliably. The aim of this study was to evaluate within and between session reliability of measuring muscle dorso-plantar thickness, medio-lateral length and cross-sectional area, of the abductor hallucis muscle using two different ultrasound machines, a higher end Philips HD11 Ultrasound machine and clinically orientated Chison 8300 Deluxe Digital Portable Ultrasound System. Methods The abductor hallucis muscle of both the left and right feet of thirty asymptomatic participants was imaged and then measured using both ultrasound machines. Interclass correlation coefficients (ICC with 95% confidence intervals (CI were used to calculate both within and between session intra-tester reliability. Standard error of the measurement (SEM calculations were undertaken to assess difference between the actual measured score across trials and the smallest real difference (SRD was calculated from the SEM to indicate the degree of change that would exceed the expected trial to trial variability. Results The ICCs, SEM and SRD for dorso-plantar thickness and medial-lateral length were shown to have excellent to high within and between-session reliability for both ultrasound machines. The between-session reliability indices for cross-sectional area were acceptable for both ultrasound machines. Conclusion The results of the current study suggest that regardless of the type ultrasound machine, intra-tester reliability for the measurement the abductor hallucis muscle parameters is very high.

  14. Inter-rater and test-retest reliability of quality assessments by novice student raters using the Jadad and Newcastle-Ottawa Scales.

    Science.gov (United States)

    Oremus, Mark; Oremus, Carolina; Hall, Geoffrey B C; McKinnon, Margaret C

    2012-01-01

    Quality assessment of included studies is an important component of systematic reviews. The authors investigated inter-rater and test-retest reliability for quality assessments conducted by inexperienced student raters. Student raters received a training session on quality assessment using the Jadad Scale for randomised controlled trials and the Newcastle-Ottawa Scale (NOS) for observational studies. Raters were randomly assigned into five pairs and they each independently rated the quality of 13-20 articles. These articles were drawn from a pool of 78 papers examining cognitive impairment following electroconvulsive therapy to treat major depressive disorder. The articles were randomly distributed to the raters. Two months later, each rater re-assessed the quality of half of their assigned articles. McMaster Integrative Neuroscience Discovery and Study Program. 10 students taking McMaster Integrative Neuroscience Discovery and Study Program courses. The authors measured inter-rater reliability using κ and the intraclass correlation coefficient type 2,1 or ICC(2,1). The authors measured test-retest reliability using ICC(2,1). Inter-rater reliability varied by scale question. For the six-item Jadad Scale, question-specific κs ranged from 0.13 (95% CI -0.11 to 0.37) to 0.56 (95% CI 0.29 to 0.83). The ranges were -0.14 (95% CI -0.28 to 0.00) to 0.39 (95% CI -0.02 to 0.81) for the NOS cohort and -0.20 (95% CI -0.49 to 0.09) to 1.00 (95% CI 1.00 to 1.00) for the NOS case-control. For overall scores on the six-item Jadad Scale, ICC(2,1)s for inter-rater and test-retest reliability (accounting for systematic differences between raters) were 0.32 (95% CI 0.08 to 0.52) and 0.55 (95% CI 0.41 to 0.67), respectively. Corresponding ICC(2,1)s for the NOS cohort were -0.19 (95% CI -0.67 to 0.35) and 0.62 (95% CI 0.25 to 0.83), and for the NOS case-control, the ICC(2,1)s were 0.46 (95% CI -0.13 to 0.92) and 0.83 (95% CI 0.48 to 0.95). Inter-rater reliability was generally poor

  15. Inter-rater and intrarater reliability of the South African Triage Scale in low-resource settings of Haiti and Afghanistan.

    Science.gov (United States)

    Dalwai, Mohammed; Tayler-Smith, Katie; Twomey, Michèle; Nasim, Masood; Popal, Abdul Qayum; Haqdost, Waliul Haq; Gayraud, Olivia; Cheréstal, Sophia; Wallis, Lee; Valles, Pola

    2018-03-16

    The South African Triage Scale (SATS) has demonstrated good validity in the EDs of Médecins Sans Frontières (MSF)-supported sites in Afghanistan and Haiti; however, corresponding reliability in these settings has not yet been reported on. This study set out to assess the inter-rater and intrarater reliability of the SATS in four MSF-supported EDs in Afghanistan and Haiti (two trauma-only EDs and two mixed (including both medical and trauma cases) EDs). Under classroom conditions between December 2013 and February 2014, ED nurses at each site assigned triage ratings to a set of context-specific vignettes (written case reports of ED patients). Inter-rater reliability was assessed by comparing triage ratings among nurses; intrarater reliability was assessed by asking the nurses to retriage 10 random vignettes from the original set and comparing these duplicate ratings. Inter-rater reliability was calculated using the unweighted kappa, linearly weighted kappa and quadratically weighted kappa (QWK) statistics, and the intraclass correlation coefficient (ICC). Intrarater reliability was calculated according to the percentage of exact agreement and the percentage of agreement allowing for one level of discrepancy in triage ratings. The correlation between years of nursing experience and reliability of the SATS was assessed based on comparison of ICCs and the respective 95% CIs. A total of 67 nurses agreed to participate in the study: In Afghanistan there were 19 nurses from Kunduz Trauma Centre and nine from Ahmed Shah Baba; in Haiti, there were 20 nurses from Martissant Emergency Centre and 19 from Tabarre Surgical and Trauma Centre. Inter-rater agreement was moderate across all sites (ICC range: 0.50-0.60; QWK range: 0.50-0.59) apart from the trauma ED in Haiti where it was moderate to substantial (ICC: 0.58; QWK: 0.61). Intrarater agreement was similar across the four sites (68%-74% exact agreement); when allowing for a one-level discrepancy in triage ratings

  16. Inter-Observer and Intra-Observer Reliability of Clinical Assessments in Knee Osteoarthritis

    Science.gov (United States)

    Maricar, Nasimah; Callaghan, Michael J; Parkes, Matthew J; Felson, David T; O’Neill, Terence W

    2016-01-01

    Background Clinical examination of the knee is subject to measurement error. The aim of this analysis was to determine inter- and intra-observer reliability of commonly used clinical tests in patients with knee osteoarthritis(OA). Methods We studied subjects with symptomatic knee OA who were participants in an open-label clinical trial of intra-articular steroid therapy. Following standardisation of the clinical test procedures, two clinicians assessed 25 subjects independently at the same visit, and the same clinician assessed 88 subjects over an interval period of 2–10 weeks; in both cases prior to the steroid intervention. Clinical examination included assessment of bony enlargement, crepitus, quadriceps wasting, knee effusion, joint-line and anserine tenderness and knee range of movement(ROM). Intra-class correlation coefficients(ICC), estimated kappa(κ), weighted kappa(κω) and Bland and Altman plots were used to determine inter- and intra-observer levels of agreement. Results Using Landis and Koch criteria, inter-observer kappa scores were moderate for patellofemoral joint(κ=0.53) and anserine tenderness(κ=0.48); good for bony enlargement(κ=0.66), quadriceps wasting(κ=0.78), crepitus(κ=0.78), medial tibiofemoral joint tenderness(κ=0.76), and effusion assessed by ballottement(κ=0.73) and bulge sign(κω =0.78); and excellent for lateral tibiofemoral joint tenderness(κ=1.00), flexion(ICC=0.97) and extension(ICC=0.87) ROM. Intra-observer kappa scores were moderate for lateral tibiofemoral joint tenderness(κ=0.60), good for crepitus(κ=0.78), effusion assessed by ballottement test(κ=0.77), patellofemoral joint(κ=0.66), medial tibiofemoral joint(κ=0.64) and anserine(κ=0.73) tenderness and excellent for effusion assessed by bulge sign(κω =0.83), bony enlargement(κ=0.98), quadriceps wasting(κ=0.83), flexion(ICC=0.99) and extension(ICC=0.96) ROM. Conclusion Among individuals with symptomatic knee OA, the reliability of clinical examination of the

  17. Inter-rater reliability and agreement of the 6-minute walk test in females with hip fractures

    DEFF Research Database (Denmark)

    Overgaard, Jan; Larsen, Camilla Marie; Tange Kristensen, Morten

    physiotherapy students independently examined (randomized order) a convenient sample of 20 participants; their assessments were separated by two days, and testing followed instructions from the American Thoracic Society. Hip pain was assessed with the Verbal Ranking Scale. Participants (all women) with a mean...... (SD) age of 78.1 ± 5.9 years performed the test within a mean of 31.5 ± 5.8 days post-surgery; 10 had a cervical and 10 a trochanteric fracture. Excellent inter-rater reliability; ICC2.1 = 0.92 (95% CI, 0.81 - 0.97) was found, and the standard error of measurement (SEM) and smallest real difference.......6 meters longer, at the second trial (P = 0.002). Participants with moderate hip fracture-related pain walked a shorter distance than those with no or light pain during the first test (P = 0.04), while this was not the case during the second (P = 0.25). Excellent inter-rater reliability was found...

  18. Inter-rater reliability and stability of diagnoses of autism spectrum disorder in children identified through screening at a very young age.

    Science.gov (United States)

    van Daalen, Emma; Kemner, Chantal; Dietz, Claudine; Swinkels, Sophie H N; Buitelaar, Jan K; van Engeland, Herman

    2009-11-01

    To examine the inter-rater reliability and stability of autism spectrum disorder (ASD) diagnoses made at a very early age in children identified through a screening procedure around 14 months of age. In a prospective design, preschoolers were recruited from a screening study for ASD. The inter-rater reliability of the diagnosis of ASD was measured through an independent assessment of a randomly selected subsample of 38 patients by two other psychiatrists. The diagnoses at 23 months and 42 months of 131 patients, based on the clinical assessment and the diagnostic classifications of standardised instruments, were compared to evaluate stability of the diagnosis of ASD. Inter-rater reliability on a diagnosis of ASD versus non-ASD at 23 months was 87% with a weighted kappa of 0.74 (SE 0.11). The stability of the different diagnoses in the autism spectrum was 63% for autistic disorder, 54% for pervasive developmental disorder, not otherwise specified (PDD-NOS), and 91% for the whole category of ASD. Most diagnostic changes at 42 months were within the autism spectrum from autistic disorder to PDD-NOS and were mainly due to diminished symptom severity. Children who moved outside the ASD category at 42 months made significantly larger gains in cognitive and language skills than children with a stable ASD diagnosis. In conclusion, the inter-rater reliability and stability of the diagnoses of ASD established at 23 months in this population-based sample of very young children are good.

  19. Tester status report: April-June 1979

    Energy Technology Data Exchange (ETDEWEB)

    Draut, C.F.

    1979-08-31

    This report details tester status and activities in support of testing of timers, actuators, detonators, firing sets, transducers, isolators, and pyrospacers for the period of April through June 1979.

  20. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    International Nuclear Information System (INIS)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders; Andersson, Anna; Biglarnia, Ali-Reza

    2012-01-01

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume

  1. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    Energy Technology Data Exchange (ETDEWEB)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders [Uppsala Univ., Dept. of Radiology, Oncology and Radiation Science, Section of Radiology, Uppsala (Sweden)], E-mail: eva.lundqvist.8954@student.uu.se; Andersson, Anna; Biglarnia, Ali-Reza [Dept. of Surgical Sciences, Section of Transplantation Surgery, Uppsala Univ. Hospital, Uppsala (Sweden)

    2012-11-15

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume.

  2. Transcultural Adaptation of GRID Hamilton Rating Scale For Depression (GRID-HAMD) to Brazilian Portuguese and Evaluation of the Impact of Training Upon Inter-Rater Reliability.

    Science.gov (United States)

    Henrique-Araújo, Ricardo; Osório, Flávia L; Gonçalves Ribeiro, Mônica; Soares Monteiro, Ivandro; Williams, Janet B W; Kalali, Amir; Alexandre Crippa, José; Oliveira, Irismar Reis De

    2014-07-01

    GRID-HAMD is a semi-structured interview guide developed to overcome flaws in HAM-D, and has been incorporated into an increasing number of studies. Carry out the transcultural adaptation of GRID-HAMD into the Brazilian Portuguese language, evaluate the inter-rater reliability of this instrument and the training impact upon this measure, and verify the raters' opinions of said instrument. The transcultural adaptation was conducted by appropriate methodology. The measurement of inter-rater reliability was done by way of videos that were evaluated by 85 professionals before and after training for the use of this instrument. The intraclass correlation coefficient (ICC) remained between 0.76 and 0.90 for GRID-HAMD-21 and between 0.72 and 0.91 for GRID-HAMD-17. The training did not have an impact on the ICC, except for a few groups of participants with a lower level of experience. Most of the participants showed high acceptance of GRID-HAMD, when compared to other versions of HAM-D. The scale presented adequate inter-rater reliability even before training began. Training did not have an impact on this measure, except for a few groups with less experience. GRID-HAMD received favorable opinions from most of the participants.

  3. Inter-rater reliability and stability of diagnoses of autism spectrum disorder in children identified through screening at a very young age

    NARCIS (Netherlands)

    van Daalen, Emma; Kemner, Chantal; Dietz, Claudine; Swinkels, Sophie H. N.; Buitelaar, Jan K.; van Engeland, Herman

    2009-01-01

    To examine the inter-rater reliability and stability of autism spectrum disorder (ASD) diagnoses made at a very early age in children identified through a screening procedure around 14 months of age. In a prospective design, preschoolers were recruited from a screening study for ASD. The inter-rater

  4. Inter-rater reliability and stability of diagnoses of autism spectrum disorder in children identified through screening at a very young age.

    NARCIS (Netherlands)

    Daalen, E. van; Kemner, C.; Dietz, C.; Swinkels, S.H.N.; Buitelaar, J.K.; Engeland, H.M. van

    2009-01-01

    To examine the inter-rater reliability and stability of autism spectrum disorder (ASD) diagnoses made at a very early age in children identified through a screening procedure around 14 months of age. In a prospective design, preschoolers were recruited from a screening study for ASD. The inter-rater

  5. Inter-rater and test–retest reliability of quality assessments by novice student raters using the Jadad and Newcastle–Ottawa Scales

    Science.gov (United States)

    Oremus, Carolina; Hall, Geoffrey B C; McKinnon, Margaret C

    2012-01-01

    Introduction Quality assessment of included studies is an important component of systematic reviews. Objective The authors investigated inter-rater and test–retest reliability for quality assessments conducted by inexperienced student raters. Design Student raters received a training session on quality assessment using the Jadad Scale for randomised controlled trials and the Newcastle–Ottawa Scale (NOS) for observational studies. Raters were randomly assigned into five pairs and they each independently rated the quality of 13–20 articles. These articles were drawn from a pool of 78 papers examining cognitive impairment following electroconvulsive therapy to treat major depressive disorder. The articles were randomly distributed to the raters. Two months later, each rater re-assessed the quality of half of their assigned articles. Setting McMaster Integrative Neuroscience Discovery and Study Program. Participants 10 students taking McMaster Integrative Neuroscience Discovery and Study Program courses. Main outcome measures The authors measured inter-rater reliability using κ and the intraclass correlation coefficient type 2,1 or ICC(2,1). The authors measured test–retest reliability using ICC(2,1). Results Inter-rater reliability varied by scale question. For the six-item Jadad Scale, question-specific κs ranged from 0.13 (95% CI −0.11 to 0.37) to 0.56 (95% CI 0.29 to 0.83). The ranges were −0.14 (95% CI −0.28 to 0.00) to 0.39 (95% CI −0.02 to 0.81) for the NOS cohort and −0.20 (95% CI −0.49 to 0.09) to 1.00 (95% CI 1.00 to 1.00) for the NOS case–control. For overall scores on the six-item Jadad Scale, ICC(2,1)s for inter-rater and test–retest reliability (accounting for systematic differences between raters) were 0.32 (95% CI 0.08 to 0.52) and 0.55 (95% CI 0.41 to 0.67), respectively. Corresponding ICC(2,1)s for the NOS cohort were −0.19 (95% CI −0.67 to 0.35) and 0.62 (95% CI 0.25 to 0.83), and for the NOS case–control, the ICC(2

  6. Development of the tyre tester

    CSIR Research Space (South Africa)

    Kuduntwane, P

    2012-10-01

    Full Text Available of the tyre tester P KUDUNTWANE1, DU PLESSIS2 AND PROF. S ELS3 1CSIR Defence, Peace, Safety and Security, PO Box 395, Pretoria, South Africa, 0001 2Department of Mechanical Engineering, Central University of Technology, Private Bag X20539, Bloemfontein...

  7. Intra- and inter-rater reliability of 3D passive intervertebral motion in subjects with nonspecific neck pain assessed by physical therapy students: A pilot study.

    Science.gov (United States)

    Rossettini, Giacomo; Rondoni, Angie; Lovato, Tommaso; Strobe, Marco; Verzè, Elisa; Vicentini, Marco; Testa, Marco

    2016-06-03

    Passive Intervertebral Movements (PIVMs) are commonly used to assess and treat patients with nonspecific neck pain. Only very few studies have investigated 3D movements until now. This study assessed intra- and inter-rater reliability of three-dimensional (3D) cervical PIVMs performed by physical therapy students in patients with nonspecific neck pain. Thirty-one patients, mean age 47.2 ± 7.2 years, were independently evaluated by 2 physical therapy students. The raters (A and B) assessed mobility, end-feel and pain provocation performing bilaterally the 3D cervical segmental side-bending test (3D CSSB) from levels C2-C3 to C6-C7. Percentage agreement (raw, positive and negative), Cohen's kappa (95% CI), prevalence index and bias index were calculated to estimate intra- and inter-reliability. Intra-rater reliability showed kappa values ranging between fair and substantial (k 0.29-0.80) for pain provocation, mobility and end-feel, with percentage agreements between 61%-90%. Inter-rater reliability presented kappa values ranging between fair and substantial (k 0.22-0.62) for pain provocation, mobility and end-feel, with percentage agreements between 61% and 80%. Intra-rater reliability of 3D PIVMs was superior to inter-rater reliability in patients with nonspecific neck pain. The most repeatable evaluation parameter was pain. However overall poor reliability suggests avoiding the use of these techniques alone to examine patients and measure their outcome. Further studies are needed to investigate PIVMs reliability in combination with other assessment procedure in symptomatic patients.

  8. Computing Inter-Rater Reliability for Observational Data: An Overview and Tutorial

    Directory of Open Access Journals (Sweden)

    Kevin A. Hallgren

    2012-02-01

    Full Text Available Many research designs require the assessment of inter-rater reliability (IRR to demonstrate consistency among observational ratings provided by multiple coders. However, many studies use incorrect statistical procedures, fail to fully report the information necessary to interpret their results, or do not address how IRR affects the power of their subsequent analyses for hypothesis testing. This paper provides an overview of methodological issues related to the assessment of IRR with a focus on study design, selection of appropriate statistics, and the computation, interpretation, and reporting of some commonly-used IRR statistics. Computational examples include SPSS and R syntax for computing Cohen’s kappa and intra-class correlations to assess IRR.

  9. Can Physicians Identify Inappropriate Nuclear Stress Tests? An Examination of Inter-rater Reliability for the 2009 Appropriate Use Criteria for Radionuclide Imaging

    Science.gov (United States)

    Ye, Siqin; Rabbani, LeRoy E.; Kelly, Christopher R.; Kelly, Maureen R.; Lewis, Matthew; Paz, Yehuda; Peck, Clara L.; Rao, Shaline; Bokhari, Sabahat; Weiner, Shepard D.; Einstein, Andrew J.

    2014-01-01

    Background We sought to determine inter-rater reliability of the 2009 Appropriate Use Criteria (AUC) for radionuclide imaging (RNI) and whether physicians at various levels of training can effectively identify nuclear stress tests with inappropriate indications. Methods and Results Four hundred patients were randomly selected from a consecutive cohort of patients undergoing nuclear stress testing at an academic medical center. Raters with different levels of training (including cardiology attending physicians, cardiology fellows, internal medicine hospitalists, and internal medicine interns) classified individual nuclear stress tests using the 2009 AUC. Consensus classification by two cardiologists was considered the operational gold standard, and sensitivity and specificity of individual raters for identifying inappropriate tests was calculated. Inter-rater reliability of the AUC was assessed using Cohen’s kappa statistics for pairs of different raters. The mean age of patients was 61.5 years; 214 (54%) were female. The cardiologists rated 256 (64%) of 400 NSTs as appropriate, 68 (18%) as uncertain, 55 (14%) as inappropriate; 21 (5%) tests were unable to be classified. Inter-rater reliability for non-cardiologist raters was modest (unweighted Cohen’s kappa, 0.51, 95% confidence interval, 0.45 to 0.55). Sensitivity of individual raters for identifying inappropriate tests ranged from 47% to 82%, while specificity ranged from 85% to 97%. Conclusions Inter-rater reliability for the 2009 AUC for RNI is modest, and there is considerable variation in the ability of raters at different levels of training to identify inappropriate tests. PMID:25563660

  10. Development of roller type side slip tester; Roller shiki side slip tester no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Nishiyama, S [Hiroshima City Industrial Technology Institute, Hiroshima (Japan); Harada, S; Harada, K

    1997-10-01

    This paper presents a new development of roller type side slip tester (RTSSI). The test equipment consists of four parts, which are developed in this research. These are a roller part, a control part, a remote control part and a CRT part. In this study, we especially investigated the mechanism and performance between tire and roller. We analyzed the amount of side slip with various toe angles. The developed tester is examined under the conditions that is considered in industrial applications. We investigated the influences of toe angle, size of tire, pressure of tire, coefficient of friction between tire and roller, pushing force of tire, revolution velocity of roller, axle load and so on. The validity of the developed RTSST is confirmed under these conditions. It was found that the RTSST can be used in practical use. Some measurement results are presented in the form of parametric plots. And we also compared measurements data between the RTSST and that of flat type using several automobiles. 4 refs., 8 figs., 4 tabs.

  11. Inter-rater reliability of the German version of the Nurses' Global Assessment of Suicide Risk scale.

    Science.gov (United States)

    Kozel, Bernd; Grieser, Manuela; Abderhalden, Christoph; Cutcliffe, John R

    2016-10-01

    In comparison to the general population, the suicide rates of psychiatric inpatient populations in Germany and Switzerland are very high. An important preventive contribution to the lowering of the suicide rates in mental health care is to ensure that the risk of suicide of psychiatric inpatients is assessed as accurately as possible. While risk-assessment instruments can serve an important function in determining such risk, very few have been translated to German. Therefore, in the present study, we reported on the German version of Nurses' Global Assessment of Suicide Risk (NGASR) scale. After translating the original instrument into German and pretesting the German version, we tested the inter-rater reliability of the instrument. Twelve video case studies were evaluated by 13 raters with the NGASR scale in a 'laboratory' trial. In each case, the observer's agreement was calculated for the single items, the overall scale, the risk levels, and the sum scores. The statistical data analysis was conducted with kappa and AC1 statistics for dichotomous (items, scale) scales. A high-to-very high observers' agreement (AC1: 0.62-1.00, kappa: 0.00-1.00) was determined for 16 items of the German version of the NGASR scale. We conclude that the German version of the NGASR scale is a reliable instrument for evaluating risk factors for suicide. A reliable application in the clinical practise appears to be enhanced by training in the use of the instrument and the right implementation instructions. © 2016 Australian College of Mental Health Nurses Inc.

  12. Measuring the quality of life in mild to very severe dementia: testing the inter-rater and intra-rater reliability of the German version of the QUALIDEM.

    Science.gov (United States)

    Dichter, Martin Nikolaus; Schwab, Christian G G; Meyer, Gabriele; Bartholomeyczik, Sabine; Dortmann, Olga; Halek, Margareta

    2014-05-01

    Quality of life (Qol) is an increasingly used outcome measure in dementia research. The QUALIDEM is a dementia-specific and proxy-rated Qol instrument. We aimed to determine the inter-rater and intra-rater reliability in residents with dementia in German nursing homes. The QUALIDEM consists of nine subscales that were applied to a sample of 108 people with mild to severe dementia and six consecutive subscales that were applied to a sample of 53 people with very severe dementia. The proxy raters were 49 registered nurses and nursing assistants. Inter-rater and intra-rater reliability scores were calculated on the subscale and item level. None of the QUALIDEM subscales showed strong inter-rater reliability based on the single-measure Intra-Class Correlation Coefficient (ICC) for absolute agreement ≥ 0.70. Based on the average-measure ICC for four raters, eight subscales for people with mild to severe dementia (care relationship, positive affect, negative affect, restless tense behavior, social relations, social isolation, feeling at home and having something to do) and five subscales for very severe dementia (care relationship, negative affect, restless tense behavior, social relations and social isolation) yielded a strong inter-rater agreement (ICC: 0.72-0.86). All of the QUALIDEM subscales, regardless of dementia severity, showed strong intra-rater agreement. The ICC values ranged between 0.70 and 0.79 for people with mild to severe dementia and between 0.75 and 0.87 for people with very severe dementia. This study demonstrated insufficient inter-rater reliability and sufficient intra-rater reliability for all subscales of both versions of the German QUALIDEM. The degree of inter-rater reliability can be improved by collaborative Qol rating by more than one nurse. The development of a measurement manual with accurate item definitions and a standardized education program for proxy raters is recommended.

  13. The inter-rater reliability of the incontinence-associated dermatitis intervention tool-D (IADIT-D) between two independent registered nurses of nursing home residents in long-term care facilities.

    Science.gov (United States)

    Braunschmidt, Brigitte; Müller, Gerhard; Jukic-Puntigam, Margareta; Steininger, Alfred

    2013-01-01

    Incontinence-associated dermatitis (IAD) is the clinical manifestation of moisture related skin damage (Beeckman, Woodward, & Gray, 2011). Valid assessment instruments are needed for risk assessment and classification of IAD. Aim of the quantitative-descriptive cross-sectional study was to determine the inter-rater reliability of the item scores of the German Incontinence Associated Dermatitis Intervention Tool (IADIT-D) between two independent assessors of nursing home residents (n = 381) in long-term care facilities. The 19 pairs of assessors consisted of registered nurses. The data analysis was computed first with the calculation of the total percentage of agreement. Because this value is not randomly adjusted, the calculation of the Kappa-coefficients and AC1-Statistic was done as well. The total percentage of the inter-rater agreement was 84% (n = 319). In a second step of analysis, the calculation of all items determined high (kappa = .70) and very high agreement (AC1 = .83) levels, respectively. For the risk assessment (kappa = .82; AC1 = .94), the values amounted to very high agreement levels and for the classification (kappa(w) = .70; AC1 = .76) to high agreement levels. The high to very high agreement values of IADIT-D demonstrate that the items can be regarded as stable in regards to the inter-rater reliability for the use in long-term care facilities. In addition, further validation studies are needed.

  14. Product-Improvement Test (Phase II), Jetcal Tester, Model H119A.

    Science.gov (United States)

    1969-03-05

    Ao—A0 51 113 ARMY AVIATION ‘Cs’ BOARD FORT tUCKER ALA — P*OOUCTeII ROVEMCNT TEST ( FHAS ~ I I ) . JETCAL TESTER, MODEL M119A~~’ETC(U) MAR S9...Phase i i ) , Jetcal Tester , Model H 119A , USATECOM Project No. 4-6-5011-03 b . No fur ther consideration be given to the TEMPCAL heater probe as a...essen t i a l component of the Jetcal Tester. e. The service manual instruct ions for con t inu i ty te s t ing of EG1 thermocouples be revised to

  15. Tester of the TRT front-end electronics for the ATLAS-experiment

    CERN Document Server

    Hajduk, Z; Kisielewski, B; Kotarba, A; Malecki, P; Natkaniec, Z; Olszowska, J; Ostrowicz, W; Krupinska, G

    2000-01-01

    The VME based tester for front-end electronics of the TRT (Transition Radiation Tracker) detector of the ATLAS-LHC experiment at CERN, Geneva, is described. The TRT read-out electronics for 424576 proportional tubes grouped on many thousands of cards requires stringent quality control after assembly and during installation. The tester provides all required data, pulses, timing and power supplies for tested cards. The essential part of the tester is its software that allows for device handling as well as facilitates functional and statistical tests. The prototype, present design as well as the new design for mass production tests are discussed. (17 refs).

  16. Reliability on intra-laboratory and inter-laboratory data of hair mineral analysis comparing with blood analysis.

    Science.gov (United States)

    Namkoong, Sun; Hong, Seung Phil; Kim, Myung Hwa; Park, Byung Cheol

    2013-02-01

    Nowadays, although its clinical value remains controversial institutions utilize hair mineral analysis. Arguments about the reliability of hair mineral analysis persist, and there have been evaluations of commercial laboratories performing hair mineral analysis. The objective of this study was to assess the reliability of intra-laboratory and inter-laboratory data at three commercial laboratories conducting hair mineral analysis, compared to serum mineral analysis. Two divided hair samples taken from near the scalp were submitted for analysis at the same time, to all laboratories, from one healthy volunteer. Each laboratory sent a report consisting of quantitative results and their interpretation of health implications. Differences among intra-laboratory and interlaboratory data were analyzed using SPSS version 12.0 (SPSS Inc., USA). All the laboratories used identical methods for quantitative analysis, and they generated consistent numerical results according to Friedman analysis of variance. However, the normal reference ranges of each laboratory varied. As such, each laboratory interpreted the patient's health differently. On intra-laboratory data, Wilcoxon analysis suggested they generated relatively coherent data, but laboratory B could not in one element, so its reliability was doubtful. In comparison with the blood test, laboratory C generated identical results, but not laboratory A and B. Hair mineral analysis has its limitations, considering the reliability of inter and intra laboratory analysis comparing with blood analysis. As such, clinicians should be cautious when applying hair mineral analysis as an ancillary tool. Each laboratory included in this study requires continuous refinement from now on for inducing standardized normal reference levels.

  17. Approaches to describing inter-rater reliability of the overall clinical appearance of febrile infants and toddlers in the emergency department

    Directory of Open Access Journals (Sweden)

    Paul Walsh

    2014-11-01

    Full Text Available Objectives. To measure inter-rater agreement of overall clinical appearance of febrile children aged less than 24 months and to compare methods for doing so.Study Design and Setting. We performed an observational study of inter-rater reliability of the assessment of febrile children in a county hospital emergency department serving a mixed urban and rural population. Two emergency medicine healthcare providers independently evaluated the overall clinical appearance of children less than 24 months of age who had presented for fever. They recorded the initial ‘gestalt’ assessment of whether or not the child was ill appearing or if they were unsure. They then repeated this assessment after examining the child. Each rater was blinded to the other’s assessment. Our primary analysis was graphical. We also calculated Cohen’s κ, Gwet’s agreement coefficient and other measures of agreement and weighted variants of these. We examined the effect of time between exams and patient and provider characteristics on inter-rater agreement.Results. We analyzed 159 of the 173 patients enrolled. Median age was 9.5 months (lower and upper quartiles 4.9–14.6, 99/159 (62% were boys and 22/159 (14% were admitted. Overall 118/159 (74% and 119/159 (75% were classified as well appearing on initial ‘gestalt’ impression by both examiners. Summary statistics varied from 0.223 for weighted κ to 0.635 for Gwet’s AC2. Inter rater agreement was affected by the time interval between the evaluations and the age of the child but not by the experience levels of the rater pairs. Classifications of ‘not ill appearing’ were more reliable than others.Conclusion. The inter-rater reliability of emergency providers’ assessment of overall clinical appearance was adequate when described graphically and by Gwet’s AC. Different summary statistics yield different results for the same dataset.

  18. Inter- and intrarater reliability of the Chicago Classification in pediatric high-resolution esophageal manometry recordings

    NARCIS (Netherlands)

    Singendonk, M. M. J.; Smits, M. J.; Heijting, I. E.; van Wijk, M. P.; Nurko, S.; Rosen, R.; Weijenborg, P. W.; Abu-Assi, R.; Hoekman, D. R.; Kuizenga-Wessel, S.; Seiboth, G.; Benninga, M. A.; Omari, T. I.; Kritas, S.

    2015-01-01

    The Chicago Classification (CC) facilitates interpretation of high-resolution manometry (HRM) recordings. Application of this adult based algorithm to the pediatric population is unknown. We therefore assessed intra and interrater reliability of software-based CC diagnosis in a pediatric cohort.

  19. Qualitative soil moisture assessment in semi-arid Africa - the role of experience and training on inter-rater reliability

    Science.gov (United States)

    Rinderer, M.; Komakech, H. C.; Müller, D.; Wiesenberg, G. L. B.; Seibert, J.

    2015-08-01

    Soil and water management is particularly relevant in semi-arid regions to enhance agricultural productivity. During periods of water scarcity, soil moisture differences are important indicators of the soil water deficit and are traditionally used for allocating water resources among farmers of a village community. Here we present a simple, inexpensive soil wetness classification scheme based on qualitative indicators which one can see or touch on the soil surface. It incorporates the local farmers' knowledge on the best soil moisture conditions for seeding and brick making in the semi-arid environment of the study site near Arusha, Tanzania. The scheme was tested twice in 2014 with farmers, students and experts (April: 40 persons, June: 25 persons) for inter-rater reliability, bias of individuals and functional relation between qualitative and quantitative soil moisture values. During the test in April farmers assigned the same wetness class in 46 % of all cases, while students and experts agreed on about 60 % of all cases. Students who had been trained in how to apply the method gained higher inter-rater reliability than their colleagues with only a basic introduction. When repeating the test in June, participants were given improved instructions, organized in small subgroups, which resulted in a higher inter-rater reliability among farmers. In 66 % of all classifications, farmers assigned the same wetness class and the spread of class assignments was smaller. This study demonstrates that a wetness classification scheme based on qualitative indicators is a robust tool and can be applied successfully regardless of experience in crop growing and education level when an in-depth introduction and training is provided. The use of a simple and clear layout of the assessment form is important for reliable wetness class assignments.

  20. Qualitative soil moisture assessment in semi-arid Africa: the role of experience and training on inter-rater reliability

    Science.gov (United States)

    Rinderer, M.; Komakech, H.; Müller, D.; Seibert, J.

    2015-03-01

    Soil and water management is particularly relevant in semi-arid regions to enhance agricultural productivity. During periods of water scarcity soil moisture differences are important indicators of the soil water deficit and are traditionally used for allocating water resources among farmers of a village community. Here we present a simple, inexpensive soil wetness classification scheme based on qualitative indicators which one can see or touch on the soil surface. It incorporates the local farmers' knowledge on the best soil moisture conditions for seeding and brick making in the semi-arid environment of the study site near Arusha, Tanzania. The scheme was tested twice in 2014 with farmers, students and experts (April: 40 persons, June: 25 persons) for inter-rater reliability, bias of individuals and functional relation between qualitative and quantitative soil moisture values. During the test in April farmers assigned the same wetness class in 46% of all cases while students and experts agreed in about 60% of all cases. Students who had been trained in how to apply the method gained higher inter-rater reliability than their colleagues with only a basic introduction. When repeating the test in June, participants were given improved instructions, organized in small sub-groups, which resulted in a higher inter-rater reliability among farmers. In 66% of all classifications farmers assigned the same wetness class and the spread of class assignments was smaller. This study demonstrates that a wetness classification scheme based on qualitative indicators is a robust tool and can be applied successfully regardless of experience in crop growing and education level when an in-depth introduction and training is provided. The use of a simple and clear layout of the assessment form is important for reliable wetness class assignments.

  1. Inter-rater reliability of assessment of levator ani muscle strength and attachment to the pubic bone in nulliparous women.

    Science.gov (United States)

    van Delft, K; Schwertner-Tiepelmann, N; Thakar, R; Sultan, A H

    2013-09-01

    The modified Oxford scale (MOS) has been found previously to have poor inter-rater reliability, whereas digital assessment of levator ani muscle (LAM) attachment to the pubic bone has been shown to have acceptable reliability. Our aim was to evaluate inter-rater reliability of the validated MOS and to develop a reliable classification system for digital assessment of LAM attachment, correlating this to findings on transperineal ultrasound (TPUS) examination. Evaluation of the MOS by palpation was performed in nulliparous women by two investigators. LAM attachment was evaluated using digital palpation, for which a novel classification system was developed with four grades based on the position of the attachment and presence of discernible muscle. Findings were compared with those on TPUS examination. Inter-rater reliability was assessed using Cohen's kappa statistic. Twenty-five nulliparous women were examined. There was agreement in MOS scores between the investigators in 64% of women (n = 16), with a kappa of 0.66 (indicating substantial agreement). There was agreement in palpation of LAM attachment using the new grading system in 96% of women (n = 24), with a kappa of 0.90 (indicating almost perfect agreement). TPUS examination did not show LAM avulsion in any woman, with the exception of one with a partial avulsion. In this group of nulliparous patients, there was substantial agreement between the two investigators in evaluation of the MOS and there was good agreement between grades of LAM attachment using the new classification system, which correlated with findings on TPUS examination. It therefore appears that these results are reproducible in nulliparous women and the techniques can be readily learned and reliably incorporated into clinical practice and research after appropriate training. Further research is required to establish clinical utility of the grading system for LAM attachment in postpartum women and in women with symptomatic pelvic organ

  2. Scoring haemophilic arthropathy on X-rays: improving inter- and intra-observer reliability and agreement using a consensus atlas

    Energy Technology Data Exchange (ETDEWEB)

    Foppen, Wouter; Schaaf, Irene C. van der; Beek, Frederik J.A. [University Medical Center Utrecht, Department of Radiology (Netherlands); Verkooijen, Helena M. [University Medical Center Utrecht, Department of Radiology (Netherlands); University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands); Fischer, Kathelijn [University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands); University Medical Center Utrecht, Van Creveldkliniek, Department of Hematology, Utrecht (Netherlands)

    2016-06-15

    The radiological Pettersson score (PS) is widely applied for classification of arthropathy to evaluate costly haemophilia treatment. This study aims to assess and improve inter- and intra-observer reliability and agreement of the PS. Two series of X-rays (bilateral elbows, knees, and ankles) of 10 haemophilia patients (120 joints) with haemophilic arthropathy were scored by three observers according to the PS (maximum score 13/joint). Subsequently, (dis-)agreement in scoring was discussed until consensus. Example images were collected in an atlas. Thereafter, second series of 120 joints were scored using the atlas. One observer rescored the second series after three months. Reliability was assessed by intraclass correlation coefficients (ICC), agreement by limits of agreement (LoA). Median Pettersson score at joint level (PS{sub joint}) of affected joints was 6 (interquartile range 3-9). Using the consensus atlas, inter-observer reliability of the PS{sub joint} improved significantly from 0.94 (95 % confidence interval (CI) 0.91-0.96) to 0.97 (CI 0.96-0.98). LoA improved from ±1.7 to ±1.1 for the PS{sub joint}. Therefore, true differences in arthropathy were differences in the PS{sub joint} of >2 points. Intra-observer reliability of the PS{sub joint} was 0.98 (CI 0.97-0.98), intra-observer LoA were ±0.9 points. Reliability and agreement of the PS improved by using a consensus atlas. (orig.)

  3. Inter-examiner reliability of a standardized Ultra-sonographic method for classification of changes related to supraspinatus tendinopathy – a pilot study

    DEFF Research Database (Denmark)

    Larsen, Camilla Marie; Ingwersen, Kim Gordon; Hjarnbæk, John

    2015-01-01

    Inter-examiner reliability of a standardized Ultra-sonographic method for classification of changes related to supraspinatus tendinopathy – a pilot study Ingwersen KG1, 2, Hjarbaek J3, Eshøj H1, Larsen CM1, 4, Vobbe J5, Juul-Kristensen B1, 6 1Institute of Sports Science and Clinical Biomechanics......, University of Southern Denmark, Odense, Denmark. 2Physiotherapy Department, Hospital Lillebaelt, Vejle Hospital, Vejle, Denmark 3Department of Radiology, Musculoskeletal section, Odense University Hospital, Odense, Denmark 4Health Sciences Research Centre, University College Lillebaelt, Odense Denmark 5...... athletes. For optimizing rehabilitation to the different stages of tendinopathy (1) ultra-sonography (US) may be used. Reliability of such method for RT is lacking. Aims. To develop and test inter-examiner reliability of US for classifying RT. Materials and Methods. A three-phased standardized protocol...

  4. Six of one, half a dozen of the other: A measure of multidisciplinary inter/intra-rater reliability of the society for fetal urology and urinary tract dilation grading systems for hydronephrosis.

    Science.gov (United States)

    Rickard, Mandy; Easterbrook, Bethany; Kim, Soojin; Farrokhyar, Forough; Stein, Nina; Arora, Steven; Belostotsky, Vladamir; DeMaria, Jorge; Lorenzo, Armando J; Braga, Luis H

    2017-02-01

    The urinary tract dilation (UTD) classification system was introduced to standardize terminology in the reporting of hydronephrosis (HN), and bridge a gap between pre- and postnatal classification such as the Society for Fetal Urology (SFU) grading system. Herein we compare the intra/inter-rater reliability of both grading systems. SFU (I-IV) and UTD (I-III) grades were independently assigned by 13 raters (9 pediatric urology staff, 2 nephrologists, 2 radiologists), twice, 3 weeks apart, to 50 sagittal postnatal ultrasonographic views of hydronephrotic kidneys. Data regarding ureteral measurements and bladder abnormalities were included to allow proper UTD categorization. Ten images were repeated to assess intra-rater reliability. Krippendorff's alpha coefficient was used to measure overall and by grade intra/inter-rater reliability. Reliability between specialties and training levels were also analyzed. Overall inter-rater reliability was slightly higher for SFU (α = 0.842, 95% CI 0.812-0.879, in session 1; and α = 0.808, 95% CI 0.775-0.839, in session 2) than for UTD (α = 0.774, 95% CI 0.715-0.827, in session 1; and α = 0.679, 95% CI 0.605-0.750, in session 2). Reliability for intermediate grades (SFU II/III and UTD 2) of HN was poor regardless of the system. Reliabilities for SFU and UTD classifications among Urology, Nephrology, and Radiology, as well as between training levels were not significantly different. Despite the introduction of HN grading systems to standardize the interpretation and reporting of renal ultrasound in infants with HN, none have been proven superior in allowing clinicians to distinguish between "moderate" grades. While this study demonstrated high reliability in distinguishing between "mild" (SFU I/II and UTD 1) and "severe" (SFU IV and UTD 3) grades of HN, the overall reliability between specialties was poor. This is in keeping with a previous report of modest inter-rater reliability of the SFU system. This drawback is

  5. The impact of revised DSM-5 criteria on the relative distribution and inter-rater reliability of eating disorder diagnoses in a residential treatment setting.

    Science.gov (United States)

    Thomas, Jennifer J; Eddy, Kamryn T; Murray, Helen B; Tromp, Marilou D P; Hartmann, Andrea S; Stone, Melissa T; Levendusky, Philip G; Becker, Anne E

    2015-09-30

    This study evaluated the relative distribution and inter-rater reliability of revised DSM-5 criteria for eating disorders in a residential treatment program. Consecutive adolescent and young adult females (N=150) admitted to a residential eating disorder treatment facility were assigned both DSM-IV and DSM-5 diagnoses by a clinician (n=14) via routine clinical interview and a research assessor (n=4) via structured interview. We compared the frequency of diagnostic assignments under each taxonomy and by type of assessor. We evaluated concordance between clinician and researcher assignment through inter-rater reliability kappa and percent agreement. Significantly fewer patients received either clinician or researcher diagnoses of a residual eating disorder under DSM-5 (clinician-12.0%; researcher-31.3%) versus DSM-IV (clinician-28.7%; researcher-59.3%), with the majority of reassigned DSM-IV residual cases reclassified as DSM-5 anorexia nervosa. Researcher and clinician diagnoses showed moderate inter-rater reliability under DSM-IV (κ=.48) and DSM-5 (κ=.57), though agreement for specific DSM-5 other specified feeding or eating disorder (OSFED) presentations was poor (κ=.05). DSM-5 revisions were associated with significantly less frequent residual eating disorder diagnoses, but not with reduced inter-rater reliability. Findings support specific dimensions of clinical utility for revised DSM-5 criteria for eating disorders. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Inter-Rater Reliability of Neck Reflex Points in Women with Chronic Neck Pain.

    Science.gov (United States)

    Weinschenk, Stefan; Göllner, Richard; Hollmann, Markus W; Hotz, Lorenz; Picardi, Susanne; Hubbert, Katharina; Strowitzki, Thomas; Meuser, Thomas

    2016-01-01

    Neck reflex points (NRP) are tender soft tissue areas of the cervical region that display reflectory changes in response to chronic inflammations of correlated regions in the visceral cranium. Six bilateral areas, NRP C0, C1, C2, C3, C4 and C7, are detectable by palpating the lateral neck. We investigated the inter-rater reliability of NRP to assess their potential clinical relevance. 32 consecutive patients with chronic neck pain were examined for NRP tenderness by an experienced physician and an inexperienced medical student in a blinded design. A detailed description of the palpation technique is included in this section. Absence of pain was defined as pain index (PI) = 0, slight tenderness = 1, and marked pain = 2. Findings were evaluated either by pair-wise Cohen's kappa (ĸ) or by percentage of agreement (PA). Examiners identified 40% and 41% of positive NRP, respectively (PI > 0, physician: 155, student: 157) with a slight preference for the left side (1.2:1). The number of patients identified with >6 positive NRP by the examiners was similar (13 vs. 12 patients). ĸ values ranged from 0.52 to 0.95. The overall kappa was ĸ = 0.80 for the left and ĸ = 0.74 for the right side. PA varied from 78.1% to 96.9% with strongest agreement at NRP C0, NRP C2, and NRP C7. Inter-rater agreement was independent of patients' age, gender, body mass index and examiner's experience. The high reproducibility suggests the clinical relevance of NRP in women. © 2016 S. Karger GmbH, Freiburg.

  7. Inter-examiner reliability of passive assessment of intervertebral motion in the cervical and lumbar spine: A systematic review

    NARCIS (Netherlands)

    van Trijffel, E.; Anderegg, Q.; Bossuyt, P. M. M.; Lucas, C.

    2005-01-01

    A systematic review was conducted to determine inter-examiner reliability of passive assessment of segmental intervertebral motion in the cervical and lumbar spine as well as to explore sources of heterogeneity. Passive assessment of motion is used to decide on treatments for neck and low-back pain

  8. Inter-rater reliability of data elements from a prototype of the Paul Coverdell National Acute Stroke Registry

    Directory of Open Access Journals (Sweden)

    Wehner Susan

    2008-06-01

    Full Text Available Abstract Background The Paul Coverdell National Acute Stroke Registry (PCNASR is a U.S. based national registry designed to monitor and improve the quality of acute stroke care delivered by hospitals. The registry monitors care through specific performance measures, the accuracy of which depends in part on the reliability of the individual data elements used to construct them. This study describes the inter-rater reliability of data elements collected in Michigan's state-based prototype of the PCNASR. Methods Over a 6-month period, 15 hospitals participating in the Michigan PCNASR prototype submitted data on 2566 acute stroke admissions. Trained hospital staff prospectively identified acute stroke admissions, abstracted chart information, and submitted data to the registry. At each hospital 8 randomly selected cases were re-abstracted by an experienced research nurse. Inter-rater reliability was estimated by the kappa statistic for nominal variables, and intraclass correlation coefficient (ICC for ordinal and continuous variables. Factors that can negatively impact the kappa statistic (i.e., trait prevalence and rater bias were also evaluated. Results A total of 104 charts were available for re-abstraction. Excellent reliability (kappa or ICC > 0.75 was observed for many registry variables including age, gender, black race, hemorrhagic stroke, discharge medications, and modified Rankin Score. Agreement was at least moderate (i.e., 0.75 > kappa ≥; 0.40 for ischemic stroke, TIA, white race, non-ambulance arrival, hospital transfer and direct admit. However, several variables had poor reliability (kappa Conclusion The excellent reliability of many of the data elements supports the use of the PCNASR to monitor and improve care. However, the poor reliability for several variables, particularly time-related events in the emergency department, indicates the need for concerted efforts to improve the quality of data collection. Specific recommendations

  9. Results of the new eddy current tester for steam generator applications

    International Nuclear Information System (INIS)

    Ribes, B.; Hernandez, J.; Barcenilla, V.

    2006-01-01

    As a result of the recent developing line of eddy current data acquisition systems a new product comes to the market named Teddy+. With only 4 kg of weight constitutes a great advance with regards to the equipments used for this type of inspections available in the market. This advances, have enabled, among others, to increase considerably the S/N ratio, avoid typical saturation problems in the eddy current signal, increase the inspection speed, eliminate the reference probe, detect the air/tube signal in real time, together with the possibility to integrate the tester inside the pusher thanks to its reduced size and to have integrated the mechanical systems control board as part of the tester. The software application in charge of data acquisition and analysis has been optimized making it possible a faster and efficient data access, incorporating a new tool to allow a data quality control on-line, which has accelerated the detection process of non-valid registers. The processes related with the supervision of different analysis have been automated enabling a simultaneous comparison of up to four different analysis types. At the same time the necessary tools to make the successive passes of the resolution process have been included in the analysis software according to EPRI guidelines. These innovations and improvements place the new SG inspection system from TECNATOM, as one of the most powerful and reliable existing in the market (orig.)

  10. Inter-device reliability of an automatic-scoring actigraph for measuring sleep in healthy adults

    Directory of Open Access Journals (Sweden)

    Matthew Driller

    2016-07-01

    Full Text Available Actigraphy has become a common method of measuring sleep due to its non-invasive, cost-effective nature. An actigraph (Readiband™ that utilizes automatic scoring algorithms has been used in the research, but is yet to be evaluated for its inter-device reliability. A total of 77 nights of sleep data from 11 healthy adult participants was collected while participants were concomitantly wearing two Readiband™ actigraphs attached together (ACT1 and ACT2. Sleep indices including total sleep time (TST, sleep latency (SL, sleep efficiency (SE%, wake after sleep onset (WASO, total time in bed (TTB, wake episodes per night (WE, sleep onset variance (SOV and wake variance (WV were assessed between the two devices using mean differences, 95% levels of agreement, intraclass correlation coefficients (ICC, typical error of measurement (TEM and coefficient of variation (CV% analysis. There were no significant differences between devices for any of the measured sleep variables (p>0.05. TST, SE, SL, TTB, SOV and WV all resulted in very high ICC's (>0.90, with WASO and WE resulting in high ICC's between devices (0.85 and 0.80, respectively. Mean differences of −2.1 and 0.2 min for TST and SL were associated with a low TEM between devices (9.5 and 3.8 min, respectively. SE resulted in a 0.3% mean difference between devices. The Readiband™ is a reliable tool for researchers using multiple devices of this brand in sleep studies to assess basic measures of sleep quality and quantity in healthy adult populations.

  11. Inter-observer variability between radiologists reporting on cerebellopontine angle tumours on magnetic resonance imaging.

    Science.gov (United States)

    Teh, S R; Ranguis, S; Fagan, P

    2017-01-01

    Studies demonstrate the significance of intra- and inter-observer variability when measuring cerebellopontine angle tumours on magnetic resonance imaging, with measured differences as high as 2 mm. To determine intra- and inter-observer measurement variability of cerebellopontine angle tumours in a specialised institution. The magnetic resonance imaging maximal diameter of 12 randomly selected cerebellopontine angle tumours were independently measured by 4 neuroradiologists at a tertiary referral centre using a standard definition for maximal tumour diameter. Average deviation and intraclass correlation were subsequently calculated. Inter-observer difference averaged 0.33 ± 0.04 mm (range, 0.0-0.8 mm). Intra-observer measurements were more consistent than inter-observer measurements, with differences averaging 0.17 mm (95 per cent confidence interval = 0.27-0.06, p = 0.002). Inter-observer reliability was 0.99 (95 per cent confidence interval = 0.97-0.99), suggesting high reliability between the readings. The use of a standard definition for maximal tumour volume provided high reliability amongst radiologists' readings. To avoid oversizing tumours, it is recommended that conservative monitoring be conducted by the same institution with thin slice magnetic resonance imaging scans.

  12. Inter-Tester Reliability and Precision of Manual Muscle Testing and Hand-Held Dynamometry in Lower Limb Muscles of Children with Spina Bifida

    Science.gov (United States)

    Mahony, Kate; Hunt, Adrienne; Daley, Deborah; Sims, Susan; Adams, Roger

    2009-01-01

    Reliability and measurement precision of manual muscle testing (MMT) and hand-held dynamometry (HHD) were compared for children with spina bifida. Strength measures were obtained of the hip flexors, hip abductors, and knee extensors of 20 children (10 males, 10 females; mean age 9 years 10 months; range: 5 to 15 years) by two experienced physical…

  13. Inter-rater reliability of three musculoskeletal physical examination techniques used to assess motion in three planes while standing.

    Science.gov (United States)

    Prather, Heidi; Hunt, Devyani; Steger-May, Karen; Hayes, Marcie Harris; Knaus, Evan; Clohisy, John

    2009-07-01

    The objective of the study was to measure the reliability between examiners of 3 basic maneuvers of the Total Body Functional Profile physical examination test. The hypothesis was musculoskeletal health care providers of different disciplines could reliably use the 3 basic maneuvers as part of the musculoskeletal physical examination. A prospective observational study was conducted. Twenty-eight adult volunteers were measured on both the left and right side by 2 independent raters on a single occasion. The subjects were recruited through advertisements placed by the orthopedic department at a tertiary university. Twenty-eight volunteers were recruited and completed the study. The volunteers were between the ages of 18 and 51 years of age, had no symptoms in the lower extremity or spine, had no previous history of surgery or tumor involving the lower extremity, and no medical conditions that would preclude participation. On a single occasion, 2 examiners per 1 volunteer were blinded to their own and each others' measurements. Each examiner assessed the distance of frontal and sagittal plane lunge and angle of motion for transverse plane testing. Inter-rater agreement is expressed with intraclass correlation coefficients (ICCs) and corresponding 95% confidence intervals (CIs). The difference between raters is reported with 95% CIs. Baseline demographics, University of California Los Angeles (UCLA), and Harris hip questionnaires were completed by all participants. The UCLA and Harris hip scores showed no significant activity restrictions or pain limitations in all participants. The inter-rater reliability for sagittal, frontal, and transverse plane matrix testing was good with ICCs of 0.86 (95% CI 0.77-0.91), 0.90 (95% CI 0.84-0.94), and 0.85 (95% CI 0.75-0.91), respectively. The rater reliability between disciplines for transverse, sagittal, and frontal plane matrix testing was good with ICCs of 0.89 (95% CI 0.80-0.94), 0.88 (95% CI 0.79-0.94), and 0.90 (95% CI 0

  14. Inter-observer and intra-observer reliability in the radiographic diagnosis of avascular necrosis of the femoral head following reconstructive hip surgery in children with cerebral palsy.

    Science.gov (United States)

    Hesketh, Kim; Sankar, Wudbhav; Joseph, Benjamin; Narayanan, Unni; Mulpuri, Kishore

    2016-04-01

    The incidence of avascular necrosis (AVN) following reconstructive hip surgery in cerebral palsy (CP) ranges from 0 to 69 % in the current literature. The purpose of this study was to determine the inter- and intra-observer reliability of radiographically diagnosing AVN in children with CP after hip surgery. A retrospective review of 65 children with CP who had reconstructive hip surgery between 2009 and 2012 at BC Children's Hospital was completed. Anterior-posterior and lateral radiographs were presented to four pediatric orthopaedic surgeons over two rounds. Surgeons were asked to review the set of unidentified radiographs and comment 'yes' or 'no' for the presence of AVN. Two weeks later the same set of radiographs was sent in a different order and the surgeons were again asked to comment on AVN. Inter- and intra-observer reliability was determined using kappa statistics. The intra-observer reliability ranged from 0.65 to 0.88 with an average score of 0.76. Inter-observer reliability showed greater variability, ranging from 0.41 to 0.77 with an average score of 0.56 across all surgeons. Although the intra-rater reliability produced a strength of "good" and the inter-rater reliability a strength of "moderate" agreement, the variability within these scores is clinically important as it demonstrates the difficulty in identifying AVN. This may explain the variability in AVN that is reported in the literature. The need for further education and research in the diagnosis of AVN in children with CP who have undergone reconstructive hip surgery is clinically necessary.

  15. Reliability and validity of the Performance Recorder 1 for measuring isometric knee flexor and extensor strength.

    Science.gov (United States)

    Neil, Sarah E; Myring, Alec; Peeters, Mon Jef; Pirie, Ian; Jacobs, Rachel; Hunt, Michael A; Garland, S Jayne; Campbell, Kristin L

    2013-11-01

    Muscular strength is a key parameter of rehabilitation programs and a strong predictor of functional capacity. Traditional methods to measure strength, such as manual muscle testing (MMT) and hand-held dynamometry (HHD), are limited by the strength and experience of the tester. The Performance Recorder 1 (PR1) is a strength assessment tool attached to resistance training equipment and may be a time- and cost-effective tool to measure strength in clinical practice that overcomes some limitations of MMT and HHD. However, reliability and validity of the PR1 have not been reported. Test-retest and inter-rater reliability was assessed using the PR1 in healthy adults (n  =  15) during isometric knee flexion and extension. Criterion-related validity was assessed through comparison of values obtained from the PR1 and Biodex® isokinetic dynamometer. Test-retest reliability was excellent for peak knee flexion (intra-class correlation coefficient [ICC] of 0.96, 95% CI: 0.85, 0.99) and knee extension (ICC  =  0.96, 95% CI: 0.87, 0.99). Inter-rater reliability was also excellent for peak knee flexion (ICC  =  0.95, 95% CI: 0.85, 0.99) and peak knee extension (ICC  =  0.97, 95% CI: 0.91, 0.99). Validity was moderate for peak knee flexion (ICC  =  0.75, 95% CI: 0.38, 0.92) but poor for peak knee extension (ICC  =  0.37, 95% CI: 0, 0.73). The PR1 provides a reliable measure of isometric knee flexor and extensor strength in healthy adults that could be used in the clinical setting, but absolute values may not be comparable to strength assessment by gold-standard measures.

  16. The intra- and inter-rater reliability of five clinical muscle performance tests in patients with and without neck pain

    Science.gov (United States)

    2013-01-01

    Background This study investigates the reliability of muscle performance tests using cost- and time-effective methods similar to those used in clinical practice. When conducting reliability studies, great effort goes into standardising test procedures to facilitate a stable outcome. Therefore, several test trials are often performed. However, when muscle performance tests are applied in the clinical setting, clinicians often only conduct a muscle performance test once as repeated testing may produce fatigue and pain, thus variation in test results. We aimed to investigate whether cervical muscle performance tests, which have shown promising psychometric properties, would remain reliable when examined under conditions similar to those of daily clinical practice. Methods The intra-rater (between-day) and inter-rater (within-day) reliability was assessed for five cervical muscle performance tests in patients with (n = 33) and without neck pain (n = 30). The five tests were joint position error, the cranio-cervical flexion test, the neck flexor muscle endurance test performed in supine and in a 45°-upright position and a new neck extensor test. Results Intra-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.48-0.82), the cranio-cervical flexion test (ICC ≥ 0.69), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.68) and in a 45°-upright position (ICC ≥ 0.41) with the exception of a new test (neck extensor test), which ranged from slight to moderate agreement (ICC = 0.14-0.41). Likewise, inter-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.51-0.75), the cranio-cervical flexion test (ICC ≥ 0.85), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.70) and in a 45°-upright position (ICC ≥ 0.56). However, only slight to fair agreement was found for the neck extensor test (ICC

  17. Cluster-based upper body marker models for three-dimensional kinematic analysis: Comparison with an anatomical model and reliability analysis.

    Science.gov (United States)

    Boser, Quinn A; Valevicius, Aïda M; Lavoie, Ewen B; Chapman, Craig S; Pilarski, Patrick M; Hebert, Jacqueline S; Vette, Albert H

    2018-04-27

    Quantifying angular joint kinematics of the upper body is a useful method for assessing upper limb function. Joint angles are commonly obtained via motion capture, tracking markers placed on anatomical landmarks. This method is associated with limitations including administrative burden, soft tissue artifacts, and intra- and inter-tester variability. An alternative method involves the tracking of rigid marker clusters affixed to body segments, calibrated relative to anatomical landmarks or known joint angles. The accuracy and reliability of applying this cluster method to the upper body has, however, not been comprehensively explored. Our objective was to compare three different upper body cluster models with an anatomical model, with respect to joint angles and reliability. Non-disabled participants performed two standardized functional upper limb tasks with anatomical and cluster markers applied concurrently. Joint angle curves obtained via the marker clusters with three different calibration methods were compared to those from an anatomical model, and between-session reliability was assessed for all models. The cluster models produced joint angle curves which were comparable to and highly correlated with those from the anatomical model, but exhibited notable offsets and differences in sensitivity for some degrees of freedom. Between-session reliability was comparable between all models, and good for most degrees of freedom. Overall, the cluster models produced reliable joint angles that, however, cannot be used interchangeably with anatomical model outputs to calculate kinematic metrics. Cluster models appear to be an adequate, and possibly advantageous alternative to anatomical models when the objective is to assess trends in movement behavior. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Inter-rater reliability of the South African Triage Scale: Assessing two different cadres of health care workers in a real time environment

    Directory of Open Access Journals (Sweden)

    Michèle Twomey

    2011-09-01

    Conclusion: The inter-rater reliability of SATS ratings is excellent within individual HCWs, but significantly lower between different HCWs. This confirms previous reliability studies of the SATS using vignettes and if validated by larger studies would support the feasibility of further implementation of the SATS in primary health care settings across the Western Cape.

  19. HIV impact on women: gender difference among late testers and advanced HIV infection

    Science.gov (United States)

    Sukmawati, N. M. D. D.; Merati, T. P.; Somia, A.; Utama, S.; Gayatri, Y.

    2018-03-01

    This study reported the effect of gender difference on HIV seropositive late testers or advanced infection. A retrospective cohort study of newly diagnosed HIV seropositive based on adatabase in the main referral hospital in Denpasar, Bali, Indonesia from 2004 – 2016. Women and man were categorized as late testers (CD4 ≤ 200 cells/uL and/or AIDS diagnosis ≤ 12 months from first HIV test date). Non-late testers (CD4 > 200 cells/uL and/or no AIDS diagnosis during study period or diagnosis of AIDS >12 months from HIV diagnosis), of reproductive age (13 – 49 years old), and not of reproductive age (>49 years old). Logistic regression was used to estimate risk and its statistical significance. The model consists of gender and age correctly classified 83.5% of cases. Women were almost two times more likely to present as non-late testers compared to men, and reproductive age of 15 – 49 years were 1.5 times more likely to present as non-late testers compared to those with age > 49 years. Women affected by HIV almost in equal as for men. Women and those within reproductive age were more likely to present before the advanced stage compared to men and those aged > 49 years.

  20. Reliability of joint count assessment in rheumatoid arthritis: a systematic literature review.

    Science.gov (United States)

    Cheung, Peter P; Gossec, Laure; Mak, Anselm; March, Lyn

    2014-06-01

    Joint counts are central to the assessment of rheumatoid arthritis (RA) but reliability is an issue. To evaluate the reliability and agreement of joint counts (intra-observer and inter-observer) by health care professionals (physicians, nurses, and metrologists) and patients in RA, and the impact of training and standardization on joint count reliability through a systematic literature review. Articles reporting joint count reliability or agreement in RA in PubMed, EMBase, and the Cochrane library between 1960 and 2012 were selected. Data were extracted regarding tender joint counts (TJCs) and swollen joint counts (SJCs) derived by physicians, metrologists, or patients for intra-observer and inter-observer reliability. In addition, methods and effects of training or standardization were extracted. Statistics expressing reliability such as intraclass correlation coefficients (ICCs) were extracted. Data analysis was primarily descriptive due to high heterogeneity. Twenty-eight studies on health care professionals (HCP) and 20 studies on patients were included. Intra-observer reliability for TJCs and SJCs was good for HCPs and patients (range of ICC: 0.49-0.98). Inter-observer reliability between HCPs for TJCs was higher than for SJCs (range of ICC: 0.64-0.88 vs. 0.29-0.98). Patient inter-observer reliability with HCPs as comparators was better for TJCs (range of ICC: 0.31-0.91) compared to SJCs (0.16-0.64). Nine studies (7 with HCPs and 2 with patients) evaluated consensus or training, with improvement in reliability of TJCs but conflicting evidence for SJCs. Intra- and inter-observer reliability was high for TJCs for HCPs and patients: among all groups, reliability was better for TJCs than SJCs. Inter-observer reliability of SJCs was poorer for patients than HCPs. Data were inconclusive regarding the potential for training to improve SJC reliability. Overall, the results support further evaluation for patient-reported joint counts as an outcome measure. © 2013

  1. How reliable are Functional Movement Screening scores? A systematic review of rater reliability.

    Science.gov (United States)

    Moran, Robert W; Schneiders, Anthony G; Major, Katherine M; Sullivan, S John

    2016-05-01

    Several physical assessment protocols to identify intrinsic risk factors for injury aetiology related to movement quality have been described. The Functional Movement Screen (FMS) is a standardised, field-expedient test battery intended to assess movement quality and has been used clinically in preparticipation screening and in sports injury research. To critically appraise and summarise research investigating the reliability of scores obtained using the FMS battery. Systematic literature review. Systematic search of Google Scholar, Scopus (including ScienceDirect and PubMed), EBSCO (including Academic Search Complete, AMED, CINAHL, Health Source: Nursing/Academic Edition), MEDLINE and SPORTDiscus. Studies meeting eligibility criteria were assessed by 2 reviewers for risk of bias using the Quality Appraisal of Reliability Studies checklist. Overall quality of evidence was determined using van Tulder's levels of evidence approach. 12 studies were appraised. Overall, there was a 'moderate' level of evidence in favour of 'acceptable' (intraclass correlation coefficient ≥0.6) inter-rater and intra-rater reliability for composite scores derived from live scoring. For inter-rater reliability of composite scores derived from video recordings there was 'conflicting' evidence, and 'limited' evidence for intra-rater reliability. For inter-rater reliability based on live scoring of individual subtests there was 'moderate' evidence of 'acceptable' reliability (κ≥0.4) for 4 subtests (Deep Squat, Shoulder Mobility, Active Straight-leg Raise, Trunk Stability Push-up) and 'conflicting' evidence for the remaining 3 (Hurdle Step, In-line Lunge, Rotary Stability). This review found 'moderate' evidence that raters can achieve acceptable levels of inter-rater and intra-rater reliability of composite FMS scores when using live ratings. Overall, there were few high-quality studies, and the quality of several studies was impacted by poor study reporting particularly in relation to

  2. Intra-Rater, Inter-Rater and Test-Retest Reliability of an Instrumented Timed Up and Go (iTUG Test in Patients with Parkinson's Disease.

    Directory of Open Access Journals (Sweden)

    Rob C van Lummel

    Full Text Available The "Timed Up and Go" (TUG is a widely used measure of physical functioning in older people and in neurological populations, including Parkinson's Disease. When using an inertial sensor measurement system (instrumented TUG [iTUG], the individual components of the iTUG and the trunk kinematics can be measured separately, which may provide relevant additional information.The aim of this study was to determine intra-rater, inter-rater and test-retest reliability of the iTUG in patients with Parkinson's Disease.Twenty eight PD patients, aged 50 years or older, were included. For the iTUG the DynaPort Hybrid (McRoberts, The Hague, The Netherlands was worn at the lower back. The device measured acceleration and angular velocity in three directions at a rate of 100 samples/s. Patients performed the iTUG five times on two consecutive days. Repeated measurements by the same rater on the same day were used to calculate intra-rater reliability. Repeated measurements by different raters on the same day were used to calculate intra-rater and inter-rater reliability. Repeated measurements by the same rater on different days were used to calculate test-retest reliability.Nineteen ICC values (15% were ≥ 0.9 which is considered as excellent reliability. Sixty four ICC values (49% were ≥ 0.70 and < 0.90 which is considered as good reliability. Thirty one ICC values (24% were ≥ 0.50 and < 0.70, indicating moderate reliability. Sixteen ICC values (12% were ≥ 0.30 and < 0.50 indicating poor reliability. Two ICT values (2% were < 0.30 indicating very poor reliability.In conclusion, in patients with Parkinson's disease the intra-rater, inter-rater, and test-retest reliability of the individual components of the instrumented TUG (iTUG was excellent to good for total duration and for turning durations, and good to low for the sub durations and for the kinematics of the SiSt and StSi. The results of this fully automated analysis of instrumented TUG movements

  3. Seven Reliability Indices for High-Stakes Decision Making: Description, Selection, and Simple Calculation

    Science.gov (United States)

    Smith, Stacey L.; Vannest, Kimberly J.; Davis, John L.

    2011-01-01

    The reliability of data is a critical issue in decision-making for practitioners in the school. Percent Agreement and Cohen's kappa are the two most widely reported indices of inter-rater reliability, however, a recent Monte Carlo study on the reliability of multi-category scales found other indices to be more trustworthy given the type of data…

  4. Portable tester for determining gas content within a core sample

    Science.gov (United States)

    Garcia, F. Jr.; Schatzel, S.J.

    1998-04-21

    A portable tester is provided for reading and displaying the pressure of a gas released from a rock core sample stored within a sealed container and for taking a sample of the released pressurized gas for chemical analysis thereof for subsequent use in a modified direct method test which determines the volume of gas and specific type of gas contained within the core sample. The portable tester includes a pair of low and high range electrical pressure transducers for detecting a gas pressure; a pair of low and high range display units for displaying the pressure of the detected gas; a selector valve connected to the low and high range pressure transducers and a selector knob for selecting gas flow to one of the flow paths; control valve having an inlet connection to the sealed container; and outlets connected to: a sample gas canister, a second outlet port connected to the selector valve means for reading the pressure of the gas from the sealed container to either the low range or high range pressure transducers, and a connection for venting gas contained within the sealed container to the atmosphere. A battery is electrically connected to and supplies the power for operating the unit. The pressure transducers, display units, selector and control valve means and the battery is mounted to and housed within a protective casing for portable transport and use. 5 figs.

  5. Hand-Drawn Resistors and a Simple Tester Using a Light-Emitting Diode

    Science.gov (United States)

    Kamata, Masahiro; Abe, Mayumi

    2012-01-01

    A thick line drawn on a sheet of paper with a 6B pencil is electrically conductive and its resistance can be roughly estimated using a simple tester made of a light-emitting diode (LED) and a lithium coin-type cell. Using this hand-drawn resistor and the LED tester, we developed teaching materials that help students to understand how electrical…

  6. Assessment of scapular positioning and function as future effect measure of shoulder interventions – an inter-examiner reliability study of the clinical assessment methods

    DEFF Research Database (Denmark)

    Larsen, Camilla Marie; Eshøj, Henrik; Ingwersen, Kim Gordon

    2015-01-01

    Assessment of scapular positioning and function as future effect measure of shoulder interventions – an inter-examiner reliability study of the clinical assessment methods Eshøj H1, Ingwersen KG1, Larsen CM1, 2, Søgaard K1, Juul-Kristensen B1, 3 1 University of Southern Denmark, Institute of Sports...... only been tested for intra-examiner reliability. The objective was to investigate the inter-examiner reliability of an extended battery of clinical tests for assessing scapular positioning and function. Methods A standardized three-phase protocol for clinical reliability studies was conducted...... coefficients (ICC) and kappa values were interpreted as: 0.0-0.40 (poor); 0.40-0.75 (fair to good); and 0.75-1.00 (good to excellent). Results A total of 41 subjects (23 males, yrs 25±9), were recruited among adult overhead athletes from the municipality of Odense, DK. Prevalence of the index condition was 54...

  7. Reliability of the Cooking Task in adults with acquired brain injury.

    Science.gov (United States)

    Poncet, Frédérique; Swaine, Bonnie; Taillefer, Chantal; Lamoureux, Julie; Pradat-Diehl, Pascale; Chevignard, Mathilde

    2015-01-01

    Acquired brain injury (ABI) often leads to deficits in executive functioning (EF) responsible for severe and long-standing disabilities in daily life activities. The Cooking Task is an ecological and valid test of EF involving multi-tasking in a real environment. Given its complex scoring system, it is important to establish the tool's reliability. The objective of the study was to examine the reliability of the Cooking Task (internal consistency, inter-rater and test-retest reliability). A total of 160 patients with ABI (113 men, mean age 37 years, SD = 14.3) were tested using the Cooking Task. For test-retest reliability, patients were assessed by the same rater on two occasions (mean interval 11 days) while two raters independently and simultaneously observed and scored patients' performances to estimate inter-rater reliability. Internal consistency was high for the global scale (Cronbach α = .74). Inter-rater reliability (n = 66) for total errors was also high (ICC = .93), however the test-retest reliability (n = 11) was poor (ICC = .36). In general the Cooking Task appears to be a reliable tool. The low test-retest results were expected given the importance of EF in the performance of novel tasks.

  8. MorphoTester: An Open Source Application for Morphological Topographic Analysis.

    Directory of Open Access Journals (Sweden)

    Julia M Winchester

    Full Text Available The increased prevalence and affordability of 3D scanning technology is beginning to have significant effects on the research questions and approaches available for studies of morphology. As the current trend of larger and more precise 3D datasets is unlikely to slow in the future, there is a need for efficient and capable tools for high-throughput quantitative analysis of biological shape. The promise and the challenge of implementing relatively automated methods for characterizing surface shape can be seen in the example of dental topographic analysis. Dental topographic analysis comprises a suite of techniques for quantifying tooth surfaces and component features. Topographic techniques have provided insight on mammalian molar form-function relationships and these methods could be applied to address other topics and questions. At the same time implementing multiple complementary topographic methods can have high time and labor costs, and comparability of data formats and approaches is difficult to predict. To address these challenges I present MorphoTester, an open source application for visualizing and quantifying topography from 3D triangulated polygon meshes. This application is Python-based and is free to use. MorphoTester implements three commonly used dental topographic metrics-Dirichlet normal energy, relief index, and orientation patch count rotated (OPCR. Previous OPCR algorithms have used raster-based grid data, which is not directly interchangeable with vector-based triangulated polygon meshes. A 3D-OPCR algorithm is provided here for quantifying complexity from polygon meshes. The efficacy of this metric is tested in a sample of mandibular second molars belonging to four species of cercopithecoid primates. Results suggest that 3D-OPCR is at least as effective for quantifying complexity as previous approaches, and may be more effective due to finer resolution of surface data considered here. MorphoTester represents an advancement

  9. Inter- and intra-rater reliability of 3D kinematics during maximum mouth opening of asymptomatic subjects.

    Science.gov (United States)

    Calixtre, Leticia Bojikian; Nakagawa, Theresa Helissa; Alburquerque-Sendín, Francisco; da Silva Grüninger, Bruno Leonardo; de Sena Rosa, Lianna Ramalho; Oliveira, Ana Beatriz

    2017-11-07

    Previous studies evaluated 3D human jaw movements using kinematic analysis systems during mouth opening, but information on the reliability of such measurements is still scarce. The purpose of this study was to analyze within- and between-session reliabilities, inter-rater reliability, standard error of measurement (SEM), minimum detectable change (MDC) and consistency of agreement across raters and sessions of 3D kinematic variables during maximum mouth opening (MMO). Thirty-six asymptomatic subjects from both genders were evaluated on two different days, five to seven days apart. Subjects performed three MMO movements while kinematic data were collected. Intraclass correlation coefficient (ICC), SEM and MDC were calculated for all variables, and Bland-Altman plots were constructed. Jaw radius and width were the most reproducible variables (ICC>0.81) and demonstrated minor error. Incisor displacement during MMO and angular movements in the sagittal plane presented good reliability (ICC from 0.61 to 0.8) and small errors and, consequently, could be used in future studies with the same methodology and population. The variables with smaller amplitudes (condylar translations during mouth opening and closing and mandibular movements on the frontal and transversal planes) were less reliable (ICCmandibular movements in the frontal and transversal planes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Open-source micro-tensile testers via additive manufacturing for the mechanical characterization of thin films and papers.

    Directory of Open Access Journals (Sweden)

    Krishanu Nandy

    Full Text Available The cost of specialized scientific equipment can be high and with limited funding resources, researchers and students are often unable to access or purchase the ideal equipment for their projects. In the fields of materials science and mechanical engineering, fundamental equipment such as tensile testing devices can cost tens to hundreds of thousands of dollars. While a research lab often has access to a large-scale testing machine suitable for conventional samples, loading devices for meso- and micro-scale samples for in-situ testing with the myriad of microscopy tools are often hard to source and cost prohibitive. Open-source software has allowed for great strides in the reduction of costs associated with software development and open-source hardware and additive manufacturing have the potential to similarly reduce the costs of scientific equipment and increase the accessibility of scientific research. To investigate the feasibility of open-source hardware, a micro-tensile tester was designed with a freely accessible computer-aided design package and manufactured with a desktop 3D-printer and off-the-shelf components. To our knowledge this is one of the first demonstrations of a tensile tester with additively manufactured components for scientific research. The capabilities of the tensile tester were demonstrated by investigating the mechanical properties of Graphene Oxide (GO paper and thin films. A 3D printed tensile tester was successfully used in conjunction with an atomic force microscope to provide one of the first quantitative measurements of GO thin film buckling under compression. The tensile tester was also used in conjunction with an atomic force microscope to observe the change in surface topology of a GO paper in response to increasing tensile strain. No significant change in surface topology was observed in contrast to prior hypotheses from the literature. Based on this result obtained with the new open source tensile stage we

  11. Open-source micro-tensile testers via additive manufacturing for the mechanical characterization of thin films and papers.

    Science.gov (United States)

    Nandy, Krishanu; Collinson, David W; Scheftic, Charlie M; Brinson, L Catherine

    2018-01-01

    The cost of specialized scientific equipment can be high and with limited funding resources, researchers and students are often unable to access or purchase the ideal equipment for their projects. In the fields of materials science and mechanical engineering, fundamental equipment such as tensile testing devices can cost tens to hundreds of thousands of dollars. While a research lab often has access to a large-scale testing machine suitable for conventional samples, loading devices for meso- and micro-scale samples for in-situ testing with the myriad of microscopy tools are often hard to source and cost prohibitive. Open-source software has allowed for great strides in the reduction of costs associated with software development and open-source hardware and additive manufacturing have the potential to similarly reduce the costs of scientific equipment and increase the accessibility of scientific research. To investigate the feasibility of open-source hardware, a micro-tensile tester was designed with a freely accessible computer-aided design package and manufactured with a desktop 3D-printer and off-the-shelf components. To our knowledge this is one of the first demonstrations of a tensile tester with additively manufactured components for scientific research. The capabilities of the tensile tester were demonstrated by investigating the mechanical properties of Graphene Oxide (GO) paper and thin films. A 3D printed tensile tester was successfully used in conjunction with an atomic force microscope to provide one of the first quantitative measurements of GO thin film buckling under compression. The tensile tester was also used in conjunction with an atomic force microscope to observe the change in surface topology of a GO paper in response to increasing tensile strain. No significant change in surface topology was observed in contrast to prior hypotheses from the literature. Based on this result obtained with the new open source tensile stage we propose an

  12. Interference of apex locator, pulp tester and diathermy on pacemaker function

    OpenAIRE

    Narayanan Sriman; V Prabhakar; J S Bhuvaneswaran; N Subha

    2015-01-01

    Aim: The purpose of this study was to evaluate the effects of three electronic apex locators (EAL), electric pulp tester (EPT) and diathermy on pacemaker function in vitro. Materials and Methods: Three EALs: Root ZX (J. Morita Co., Tustin, CA, U.S.A.), Propex (Dentsply), Mini Apex locator (SybronEndo, Anaheim, CA, USA), EPT (Parkell pulp vitality tester Farmingdale, NY, USA) and Diathermy (Neomed 250 B) were tested for any interference with one pacemaker (A medtronic kappa KVDD901-serial ...

  13. Inter-rater reliability of PATH observations for assessment of ergonomic risk factors in hospital work.

    Science.gov (United States)

    Park, Jung-Keun; Boyer, Jon; Tessler, Jamie; Casey, Jeffrey; Schemm, Linda; Gore, Rebecca; Punnett, Laura

    2009-07-01

    This study examined the inter-rater reliability of expert observations of ergonomic risk factors by four analysts. Ten jobs were observed at a hospital using a newly expanded version of the PATH method (Buchholz et al. 1996), to which selected upper extremity exposures had been added. Two of the four raters simultaneously observed each worker onsite for a total of 443 observation pairs containing 18 categorical exposure items each. For most exposure items, kappa coefficients were 0.4 or higher. For some items, agreement was higher both for the jobs with less rapid hand activity and for the analysts with a higher level of ergonomic job analysis experience. These upper extremity exposures could be characterised reliably with real-time observation, given adequate experience and training of the observers. The revised version of PATH is applicable to the analysis of jobs where upper extremity musculoskeletal strain is of concern.

  14. Reliability of the imaging software in the preoperative planning of the open-wedge high tibial osteotomy.

    Science.gov (United States)

    Lee, Yong Seuk; Kim, Min Kyu; Byun, Hae Won; Kim, Sang Bum; Kim, Jin Goo

    2015-03-01

    The purpose of this study was to verify a recently developed picture-archiving and communications system-photoshop method by comparing reliabilities between real-size paper template and the PACS-photoshop methods in preoperative planning of open-wedge high tibial osteotomy. A prospective case series was conducted, including patients with medial osteoarthritis undergoing open-wedge high tibial osteotomy. In the preoperative planning, the picture-archiving and communications system-photoshop method and real-size paper template method were used simultaneously in all patients. Preoperative hip-knee-ankle angle, height, and angle of the osteotomy were evaluated. The reliability of this newly devised method was evaluated, and the consistency between the two methods was also evaluated using intra-class correlation coefficient. Using the picture-archiving and communications system-photoshop method, the mean correction angle and height of osteotomy gap of rater-1 were 11.7° ± 3.6° and 10.7 ± 3.6 mm, respectively. The mean correction angle and height of osteotomy gap of rater-2 were 12.0 ± 2.6 and 10.8 ± 3.6, respectively. The inter- and intra-rater reliabilities of the correction angle were 0.956 ~ 0.979 and 0.980 ~ 0.992, respectively. The inter- and intra-rater reliabilities of the height of the osteotomy gap were 0.968 ~ 0.985 and 0.971 ~ 0.994, respectively (p photoshop method, mean values of the correction angle and height of the osteotomy gap were 11.9° ± 3.6° and 10.8 ± 3.6 mm, respectively. Consistency between the two methods by comparing the means of the correction angle and the height of the osteotomy gap were 0.985 and 0.985, respectively (p photoshop method enables direct measurement of the height of the osteotomy gap with high reliability.

  15. Overview of the InterGroup protocols

    Energy Technology Data Exchange (ETDEWEB)

    Berket, Karlo [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Agarwal, Deborah A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Melliar-Smith, P. Michael [Univ. of California, Santa Barbara, CA (United States); Moser, Louise E. [Univ. of California, Santa Barbara, CA (United States)

    2001-03-01

    Existing reliable ordered group communication protocols have been developed for local-area networks and do not, in general, scale well to large numbers of nodes and wide-area networks. The InterGroup suite of protocols is a scalable group communication system that introduces a novel approach to handling group membership, and supports a receiver-oriented selection of service. The protocols are intended for a wide-area network, with a large number of nodes, that has highly variable delays and a high message loss rate, such as the Internet. The levels of the message delivery service range from unreliable unordered to reliable group timestamp ordered.

  16. Accuracy, intra- and inter-unit reliability, and comparison between GPS and UWB-based position-tracking systems used for time-motion analyses in soccer.

    Science.gov (United States)

    Bastida Castillo, Alejandro; Gómez Carmona, Carlos D; De la Cruz Sánchez, Ernesto; Pino Ortega, José

    2018-05-01

    There is interest in the accuracy and inter-unit reliability of position-tracking systems to monitor players. Research into this technology, although relatively recent, has grown exponentially in the last years, and it is difficult to find professional team sport that does not use Global Positioning System (GPS) technology at least. The aim of this study is to know the accuracy of both GPS-based and Ultra Wide Band (UWB)-based systems on a soccer field and their inter- and intra-unit reliability. A secondary aim is to compare them for practical applications in sport science. Following institutional ethical approval and familiarization, 10 healthy and well-trained former soccer players (20 ± 1.6 years, 1.76 ± 0.08 cm, and 69.5 ± 9.8 kg) performed three course tests: (i) linear course, (ii) circular course, and (iii) a zig-zag course, all using UWB and GPS technologies. The average speed and distance covered were compared with timing gates and the real distance as references. The UWB technology showed better accuracy (bias: 0.57-5.85%), test-retest reliability (%TEM: 1.19), and inter-unit reliability (bias: 0.18) in determining distance covered than the GPS technology (bias: 0.69-6.05%; %TEM: 1.47; bias: 0.25) overall. Also, UWB showed better results (bias: 0.09; ICC: 0.979; bias: 0.01) for mean velocity measurement than GPS (bias: 0.18; ICC: 0.951; bias: 0.03).

  17. Intra- and interrater reliability of the Chicago Classification of achalasia subtypes in pediatric high-resolution esophageal manometry (HRM) recordings

    NARCIS (Netherlands)

    Singendonk, M. M. J.; Rosen, R.; Oors, J.; Rommel, N.; van Wijk, M. P.; Benninga, M. A.; Nurko, S.; Omari, T. I.

    2017-01-01

    BackgroundSubtyping achalasia by high-resolution manometry (HRM) is clinically relevant as response to therapy and prognosis have shown to vary accordingly. The aim of this study was to assess inter- and intrarater reliability of diagnosing achalasia and achalasia subtyping in children using the

  18. A reliability analysis of the revised competitiveness index.

    Science.gov (United States)

    Harris, Paul B; Houston, John M

    2010-06-01

    This study examined the reliability of the Revised Competitiveness Index by investigating the test-retest reliability, interitem reliability, and factor structure of the measure based on a sample of 280 undergraduates (200 women, 80 men) ranging in age from 18 to 28 years (M = 20.1, SD = 2.1). The findings indicate that the Revised Competitiveness Index has high test-retest reliability, high inter-item reliability, and a stable factor structure. The results support the assertion that the Revised Competitiveness Index assesses competitiveness as a stable trait rather than a dynamic state.

  19. Enhanced Master Controller Unit Tester

    Science.gov (United States)

    Benson, Patricia; Johnson, Yvette; Johnson, Brian; Williams, Philip; Burton, Geoffrey; McCoy, Anthony

    2007-01-01

    The Enhanced Master Controller Unit Tester (EMUT) software is a tool for development and testing of software for a master controller (MC) flight computer. The primary function of the EMUT software is to simulate interfaces between the MC computer and external analog and digital circuitry (including other computers) in a rack of equipment to be used in scientific experiments. The simulations span the range of nominal, off-nominal, and erroneous operational conditions, enabling the testing of MC software before all the equipment becomes available.

  20. Inter-observer reliability assessments in time motion studies: the foundation for meaningful clinical workflow analysis.

    Science.gov (United States)

    Lopetegui, Marcelo A; Bai, Shasha; Yen, Po-Yin; Lai, Albert; Embi, Peter; Payne, Philip R O

    2013-01-01

    Understanding clinical workflow is critical for researchers and healthcare decision makers. Current workflow studies tend to oversimplify and underrepresent the complexity of clinical workflow. Continuous observation time motion studies (TMS) could enhance clinical workflow studies by providing rich quantitative data required for in-depth workflow analyses. However, methodological inconsistencies have been reported in continuous observation TMS, potentially reducing the validity of TMS' data and limiting their contribution to the general state of knowledge. We believe that a cornerstone in standardizing TMS is to ensure the reliability of the human observers. In this manuscript we review the approaches for inter-observer reliability assessment (IORA) in a representative sample of TMS focusing on clinical workflow. We found that IORA is an uncommon practice, inconsistently reported, and often uses methods that provide partial and overestimated measures of agreement. Since a comprehensive approach to IORA is yet to be proposed and validated, we provide initial recommendations for IORA reporting in continuous observation TMS.

  1. 16 CFR Figure 3 to Subpart A of... - Flooring Radiant Tester Schematic Side Elevation

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Flooring Radiant Tester Schematic Side Elevation 3 Figure 3 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 3 Figure 3 to Subpart A of Part 1209—Flooring Radiant Tester Schematic Side...

  2. Evaluation of bearing configurations using the single bearing tester in liquid nitrogen

    Science.gov (United States)

    Jett, T.; Hall, P.; Thom, R.

    1991-01-01

    Various bearing configurations were tested using the Marshall Space Flight Center single bearing tester with LN2 as the cryogenic coolant. The baseline was one Rocketdyne phase one high pressure oxidizer turbopump (HPOTP) pump end 45-mm bore bearing. The bearing configurations that were tested included a Salox/M cage configuration, a silicon nitride ball configuration, an elongated cage configuration, and a Bray 601 grease configuration.

  3. Repeatability of the Oxford Foot Model in children with foot deformity.

    Science.gov (United States)

    McCahill, Jennifer; Stebbins, Julie; Koning, Bart; Harlaar, Jaap; Theologis, Tim

    2018-03-01

    The Oxford Foot Model (OFM) is a multi-segment, kinematic model developed to assess foot motion. It has previously been assessed for repeatability in healthy populations. To determine the OFM's reliability for detecting foot deformity, it is important to know repeatability in pathological conditions. The aim of the study was to assess the repeatability of the OFM in children with foot deformity. Intra-tester repeatability was assessed for 45 children (15 typically developing, 15 hemiplegic, 15 clubfoot). Inter-tester repeatability was assessed in the clubfoot population. The mean absolute differences between testers (clubfoot) and sessions (clubfoot and hemiplegic) were calculated for each of 15 clinically relevant, kinematic variables and compared to typically developing children. Children with clubfoot showed a mean difference between visits of 2.9° and a mean difference between raters of 3.6° Mean absolute differences were within one degree for the intra and inter-rater reliability in 12/15 variables. Hindfoot rotation, forefoot/tibia abduction and forefoot supination were the most variable between testers. Overall the clubfoot data were less variable than the typically developing population. Children with hemiplegia demonstrated slightly higher differences between sessions (mean 4.1°), with the most reliable data in the sagittal plane, and largest differences in the transverse plane. The OFM was designed to measure different types of foot deformity. The results of this study show that it provides repeatable results in children with foot deformity. To be distinguished from measurement artifact, changes in foot kinematics as a result of intervention or natural progression over time must be greater than the repeatability reported here. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Validation and inter-rater reliability of a three item falls risk screening tool

    Directory of Open Access Journals (Sweden)

    Catherine Maree Said

    2017-11-01

    Full Text Available Abstract Background Falls screening tools are routinely used in hospital settings and the psychometric properties of tools should be examined in the setting in which they are used. The aim of this study was to explore the concurrent and predictive validity of the Austin Health Falls Risk Screening Tool (AHFRST, compared with The Northern Hospital Modified St Thomas’s Risk Assessment Tool (TNH-STRATIFY, and the inter-rater reliability of the AHFRST. Methods A research physiotherapist used the AHFRST and TNH-STRATIFY to classify 130 participants admitted to Austin Health (five acute wards, n = 115 two subacute wards n = 15; median length of stay 6 days IQR 3–12 as ‘High’ or ‘Low’ falls risk. The AHFRST was also completed by nursing staff on patient admission. Falls data was collected from the hospital incident reporting system. Results Six falls occurred during the study period (fall rate of 4.6 falls per 1000 bed days. There was substantial agreement between the AHFRST and the TNH-STRATIFY (Kappa = 0.68, 95% CI 0.52–0.78. Both tools had poor predictive validity, with low specificity (AHFRST 46.0%, 95% CI 37.0–55.1; TNH-STRATIFY 34.7%, 95% CI 26.4–43.7 and positive predictive values (AHFRST 5.6%, 95% CI 1.6–13.8; TNH-STRATIFY 6.9%, 95% CI 2.6–14.4. The AHFRST showed moderate inter-rater reliability (Kappa = 0.54, 95% CI = 0.36–0.67, p < 0.001 although 18 patients did not have the AHFRST completed by nursing staff. Conclusions There was an acceptable level of agreement between the 3 item AHFRST classification of falls risk and the longer, 9 item TNH-STRATIFY classification. However, both tools demonstrated limited predictive validity in the Austin Health population. The results highlight the importance of evaluating the validity of falls screening tools, and the clinical utility of these tools should be reconsidered.

  5. Colour of Tester Effects on Children's Expressed Attitudes.

    Science.gov (United States)

    Thomas, K. C.

    1978-01-01

    Discusses a study of student attitudes, preferences, and stereotyping among White Britons and West Indian students in an English secondary school. Findings indicated that factors such as the race of the tester influenced the test situation. For journal availability, see SO 506 785. (DB)

  6. Trunk Muscle Size and Composition Assessment in Older Adults with Chronic Low Back Pain: An Intra-Examiner and Inter-Examiner Reliability Study.

    Science.gov (United States)

    Sions, Jaclyn Megan; Smith, Andrew Craig; Hicks, Gregory Evan; Elliott, James Matthew

    2016-08-01

     To evaluate intra- and inter-examiner reliability for the assessment of relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area, i.e., total cross-sectional area minus intramuscular fat, from T1-weighted magnetic resonance images obtained in older adults with chronic low back pain.  Reliability study.  n = 13 (69.3 ± 8.2 years old)  After lumbar magnetic resonance imaging, two examiners produced relative cross-sectional area measurements of multifidi, erector spinae, psoas, and quadratus lumborum by tracing regions of interest just inside fascial borders. Pixel-intensity summaries were used to determine muscle-to-fat infiltration indices; relative muscle cross-sectional area was calculated. Intraclass correlation coefficients were used to estimate intra- and inter-examiner reliability; standard error of measurement was calculated.  Intra-examiner intraclass correlation coefficient point estimates for relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area were excellent for multifidi and erector spinae across levels L2-L5 (ICC = 0.77-0.99). At L3, intra-examiner reliability was excellent for relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area for both psoas and quadratus lumborum (ICC = 0.81-0.99). Inter-examiner intraclass correlation coefficients ranged from poor to excellent for relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area.  Assessment of relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area in older adults with chronic low back pain can be reliably determined by one examiner from T1-weighted images. Such assessments provide valuable information, as muscle-to-fat infiltration indices and relative muscle cross-sectional area indicate that a substantial amount of

  7. Determining the fertility status of Setaria infecting Magnaporthe grisea isolates with standard testers and identification of tolerant cultivar of Setaria italica.

    Science.gov (United States)

    Karthikeyan, Veluswamy; Gnanamanickam, S S

    2008-10-01

    A total of 128 isolates of Setaria-infecting Magnaporthe grisea strains were obtained from different states of South India which includes sampling sites from Tamil Nadu, two from Karnataka, one from Andhra Pradesh and Kerala. Out of the selected 128 isolates 30 strains were tested with MAT1-1 and MAT1-2 fertile standard testers to determine their mating type. None of the 30 Setaria isolates produced perithecia with fertile testers. However, when monoconidial isolates were mated among themselves, isolates from the same field produced only barren perithecia and the tester isolates were able to mate readily with finger millet isolates. This is the first report of the mating-type studies on Setaria infecting Magnaporthe grisea with standard testers. This result indicates that the Setaria infecting population is infertile. In pathogenicity assay, it was found that 9 out of the 22 Setaria accessions were highly susceptible to Setaria strains of the blast fungus and seven cultivars/accessions were resistant to blast pathogen. Various virulence reactions were scored according to Standard Evaluation System.

  8. Inter-rater reliability of h-index scores calculated by Web of Science and Scopus for clinical epidemiology scientists.

    Science.gov (United States)

    Walker, Benjamin; Alavifard, Sepand; Roberts, Surain; Lanes, Andrea; Ramsay, Tim; Boet, Sylvain

    2016-06-01

    We investigated the inter-rater reliability of Web of Science (WoS) and Scopus when calculating the h-index of 25 senior scientists in the Clinical Epidemiology Program of the Ottawa Hospital Research Institute. Bibliometric information and the h-indices for the subjects were computed by four raters using the automatic calculators in WoS and Scopus. Correlation and agreement between ratings was assessed using Spearman's correlation coefficient and a Bland-Altman plot, respectively. Data could not be gathered from Google Scholar due to feasibility constraints. The Spearman's rank correlation between the h-index of scientists calculated with WoS was 0.81 (95% CI 0.72-0.92) and with Scopus was 0.95 (95% CI 0.92-0.99). The Bland-Altman plot showed no significant rater bias in WoS and Scopus; however, the agreement between ratings is higher in Scopus compared to WoS. Our results showed a stronger relationship and increased agreement between raters when calculating the h-index of a scientist using Scopus compared to WoS. The higher inter-rater reliability and simple user interface used in Scopus may render it the more effective database when calculating the h-index of senior scientists in epidemiology. © 2016 Health Libraries Group.

  9. Reliability of visual and instrumental color matching.

    Science.gov (United States)

    Igiel, Christopher; Lehmann, Karl Martin; Ghinea, Razvan; Weyhrauch, Michael; Hangx, Ysbrand; Scheller, Herbert; Paravina, Rade D

    2017-09-01

    The aim of this investigation was to evaluate intra-rater and inter-rater reliability of visual and instrumental shade matching. Forty individuals with normal color perception participated in this study. The right maxillary central incisor of a teaching model was prepared and restored with 10 feldspathic all-ceramic crowns of different shades. A shade matching session consisted of the observer (rater) visually selecting the best match by using VITA classical A1-D4 (VC) and VITA Toothguide 3D Master (3D) shade guides and the VITA Easyshade Advance intraoral spectrophotometer (ES) to obtain both VC and 3D matches. Three shade matching sessions were held with 4 to 6 weeks between sessions. Intra-rater reliability was assessed based on the percentage of agreement for the three sessions for the same observer, whereas the inter-rater reliability was calculated as mean percentage of agreement between different observers. The Fleiss' Kappa statistical analysis was used to evaluate visual inter-rater reliability. The mean intra-rater reliability for the visual shade selection was 64(11) for VC and 48(10) for 3D. The corresponding ES values were 96(4) for both VC and 3D. The percentages of observers who matched the same shade with VC and 3D were 55(10) and 43(12), respectively, while corresponding ES values were 88(8) for VC and 92(4) for 3D. The results for visual shade matching exhibited a high to moderate level of inconsistency for both intra-rater and inter-rater comparisons. The VITA Easyshade Advance intraoral spectrophotometer exhibited significantly better reliability compared with visual shade selection. This study evaluates the ability of observers to consistently match the same shade visually and with a dental spectrophotometer in different sessions. The intra-rater and inter-rater reliability (agreement of repeated shade matching) of visual and instrumental tooth color matching strongly suggest the use of color matching instruments as a supplementary tool in

  10. Ultrasound evaluation of the abductor hallucis muscle: Reliability study

    Directory of Open Access Journals (Sweden)

    Hing Wayne A

    2008-09-01

    Full Text Available Abstract Background The Abductor hallucis muscle (AbdH plays an integral role during gait and is often affected in pathological foot conditions. The aim of this study was to evaluate the within and between-session intra-tester reliability using diagnostic ultrasound of the dorso-plantar thickness, medio-lateral width and cross-sectional area, of the AbdH in asymptomatic adults. Methods The AbdH muscles of thirty asymptomatic subjects were imaged and then measured using a Philips HD11 Ultrasound machine. Interclass correlation coefficients (ICC with 95% confidence intervals (CI were used to calculate both within and between session intra-tester reliability. Results The within-session reliability results demonstrated for dorso-plantar thickness an ICC of 0.97 (95% CI: 0.99–0.99; medio-lateral width an ICC: of 0.97 (95% CI: 0.92–0.97 and cross-sectional area an ICC of 0.98 (95% CI: 0.98–0.99. Between-session reliability results demonstrated for dorso-plantar thickness an ICC of 0.97 (95% CI: 0.95 to 0.98; medio-lateral width an ICC of 0.94 (95% CI 0.90 to 0.96 and for cross-sectional area an ICC of 0.79 (95% CI 0.65 to 0.88. Conclusion Diagnostic ultrasound has the potential to be a reliable tool for evaluating the AbdH muscle in asymptomatic subjects. Subsequent studies may be conducted to provide a better understanding of the AbdH function in foot and ankle pathologies.

  11. Inter-rater reliability of postnatal ultrasound interpretation in infants with congenital hydronephrosis.

    Science.gov (United States)

    Vemulakonda, V M; Wilcox, D T; Torok, M R; Hou, A; Campbell, J B; Kempe, A

    2015-09-01

    The most common measurements of hydronephrosis are the anterior-posterior (AP) diameter and the Society for Fetal Urology (SFU) grading systems. To date, the inter-rater reliability (IRR) of these measures has not been compared in the postnatal period. The objectives of this study were to compare the IRR of the AP diameter and the SFU grading system in infants and to determine whether ultrasound findings other than pelvicalyceal dilation are associated with higher SFU grades. Initial postnatal ultrasounds of infants seen from February 1, 2011, to January 31, 2012, with a primary diagnosis of congenital hydronephrosis were included for review. Ultrasound images were de-identified and reviewed by four pediatric urologists. IRR was calculated using the intraclass correlation (ICC) measure. A paired t test was used to compare ICCs. Associations between SFU grade and other ultrasound findings were tested using Chi-square or Fisher's exact tests. A total of 112 kidneys in 56 patients were reviewed. IRR of the SFU grading system was high (right kidney ICC = 0.83, left kidney ICC = 0.85); however, IRR of AP diameter measurement was higher (right kidney ICC = 00.97, left kidney ICC = 0.98; p hydronephrosis on bivariable and multivariable analysis. The SFU grading system is associated with excellent IRR, although the AP diameter appears to have higher IRR. Physicians may consider ultrasound findings that are not explicitly included in the SFU system when assigning hydronephrosis grade, which may lead to variability in use of this classification system.

  12. Design, Construction, and Evaluation of Rubber Friction Tester

    Directory of Open Access Journals (Sweden)

    Mehdi Razzaghi Kashani

    2012-12-01

    Full Text Available Coeffcient of  friction  (COF  for  rubber parts  is one of  the key parameters in their interaction with solid rough surfaces (micrometer to millimeter scales,  such  as  tire-road  interactions. COF  of  rubber  depends  on  viscoelastic properties of rubber, roughness characteristics of the counter-part surface, and process variables such as contact nominal pressure and sliding speed. Due to the need for measuring COF  for  rubber,  a  new  friction  tester, with  continuous  variation  of nominal pressure and sliding speed, was designed and constructed in order to assess the effect of above mentioned parameters. Tire tread compounds, as the most common rubber part  in  the feld of  rubber  tribology, was used  for  this purpose. Viscoelastic properties of compounds were varied by changing composition of styrene-butadiene rubber (SBR and butadiene rubber (BR in the blend. Effect of surface roughness was evaluated by using silicon-carbide papers with different roughness parameters. By statistical analysis it was shown that the designed friction tester has high accuracy in measuring the coeffcient of friction of rubber and differentiating the effective parameters. Increasing the nominal pressure led to reduction of COF and increase in sliding speed forced it through a maximum. In conclusion, the loss factor of the compound and asymmetry in roughness distribution of the counter-surface are considered as the most effective parameters on COF of rubber.

  13. White balance tester with color sensor for industrial applications

    Science.gov (United States)

    Chen, Jiasheng; Zhu, XiaoSong

    1996-12-01

    The white balance tester is an instrument that adjusts the white balance for color TVs, monitors, and PC displays. We have designed a new white balance tester for use directly at the production line. It picks up the R (Red), G (Green), and B (Blue) signals for the screen using color sensors, compares the signals with the data previously stored in the internal memory, displays their differences with LED bars in the compare mode or displays x y Y, u v Y, JND (just noticeable difference) as well as correlated color temperature in the numerical mode. A built-in TV signal generator sets the luminance of the adjusting screen to the brightness of the reference white screen automatically. A 16-bit single chip microcomputer processes the measured values and controls the output levels of the TV signal generator.

  14. Microprocessor-controlled tester for evaluation of the Self-Energized Credential System (SECS)

    International Nuclear Information System (INIS)

    Corlis, N.E.

    1980-03-01

    The Self-Energized Credential System (SECS) was developed for use in the Plutonium Protection System (PPS) installed at Hanford, Washington. Evaluation and development of the SECS system was enhanced by the use of a microprocessor-controlled portal tester. This tester used infrared (ir) beam sensors to provide information on the direction of travel of the credential wearer and to detect inoperative credentials. A printed record of the portal number, actual code read, time, and direction of the credential passage provided information essential to an assessment of the operability of the SECS

  15. Coronary calcium screening with dual-source CT: reliability of ungated, high-pitch chest CT in comparison with dedicated calcium-scoring CT

    Energy Technology Data Exchange (ETDEWEB)

    Hutt, Antoine; Faivre, Jean-Baptiste; Remy, Jacques; Remy-Jardin, Martine [CHRU et Universite de Lille, Department of Thoracic Imaging, Hospital Calmette (EA 2694), Lille (France); Duhamel, Alain; Deken, Valerie [CHRU et Universite de Lille, Department of Biostatistics (EA 2694), Lille (France); Molinari, Francesco [Centre Hospitalier General de Tourcoing, Department of Radiology, Tourcoing (France)

    2016-06-15

    To investigate the reliability of ungated, high-pitch dual-source CT for coronary artery calcium (CAC) screening. One hundred and eighty-five smokers underwent a dual-source CT examination with acquisition of two sets of images during the same session: (a) ungated, high-pitch and high-temporal resolution acquisition over the entire thorax (i.e., chest CT); (b) prospectively ECG-triggered acquisition over the cardiac cavities (i.e., cardiac CT). Sensitivity and specificity of chest CT for detecting positive CAC scores were 96.4 % and 100 %, respectively. There was excellent inter-technique agreement for determining the quantitative CAC score (ICC = 0.986). The mean difference between the two techniques was 11.27, representing 1.81 % of the average of the two techniques. The inter-technique agreement for categorizing patients into the four ranks of severity was excellent (weighted kappa = 0.95; 95 % CI 0.93-0.98). The inter-technique differences for quantitative CAC scores did not correlate with BMI (r = 0.05, p = 0.575) or heart rate (r = -0.06, p = 0.95); 87.2 % of them were explained by differences at the level of the right coronary artery (RCA: 0.8718; LAD: 0.1008; LCx: 0.0139; LM: 0.0136). Ungated, high-pitch dual-source CT is a reliable imaging mode for CAC screening in the conditions of routine chest CT examinations. (orig.)

  16. Building instructions: a motorcar battery tester

    Energy Technology Data Exchange (ETDEWEB)

    Kunz, K

    1975-02-01

    The circuit diagram of a motor car battery tester is given, intended for dashboard mounting. The condition of the battery is indicated by means of a light-emitting diode, which may be off (below 11 V), red (11 to 12.5 V), green (12.5 to 14.8 V) or flashing red (voltage exceeding 14.8 V). The circuit uses two transistors and a single integrated circuit (four-way comparator). Details of the layout, assembly, and testing procedures are included.

  17. Validity and inter-rater reliability of medio-lateral knee motion observed during a single-limb mini squat

    DEFF Research Database (Denmark)

    Ageberg, Eva; Bennell, Kim L; Hunt, Michael A

    2010-01-01

    Muscle function may influence the risk of knee injury and outcomes following injury. Clinical tests, such as a single-limb mini squat, resemble conditions of daily life and are easy to administer. Fewer squats per 30 seconds indicate poorer function. However, the quality of movement, such as the ......, such as the medio-lateral knee motion may also be important. The aim was to validate an observational clinical test of assessing the medio-lateral knee motion, using a three-dimensional (3-D) motion analysis system. In addition, the inter-rater reliability was evaluated....

  18. Design for reliability information and computer-based systems

    CERN Document Server

    Bauer, Eric

    2010-01-01

    "System reliability, availability and robustness are often not well understood by system architects, engineers and developers. They often don't understand what drives customer's availability expectations, how to frame verifiable availability/robustness requirements, how to manage and budget availability/robustness, how to methodically architect and design systems that meet robustness requirements, and so on. The book takes a very pragmatic approach of framing reliability and robustness as a functional aspect of a system so that architects, designers, developers and testers can address it as a concrete, functional attribute of a system, rather than an abstract, non-functional notion"--Provided by publisher.

  19. Trial manufacture of rotary friction tester and frictional force measurement of metals

    CERN Document Server

    Abe, T; Kanari, M; Tanzawa, S

    2002-01-01

    In the plasma confinement type fusion reactor, in-vessel structures such as a blanket module slide at the joints each other when plasma disruption occurs, and then frictional heat is generated there. Therefore, for the selection of material and the use as the design data, it is important to understand the frictional characteristics of metals and ceramic films in the vacuum. In the present study, we have manufactured a prototype of rotary friction tester and examined the performances of the tester. The frictional characteristics of metals in the room air was measured using the friction tester, and the results obtained are as follows. A drifting friction force for a constant time and a friction force during the idling were 98 mN and 225 mN, respectively. These values were sufficiently small as compared to pressing load (9.8 - 57.8 N) used in the friction test. In a friction force measurement of stainless steel, dynamic friction force obeyed Amontons' law which indicated that dynamic friction force is not depend...

  20. Content Validity Index and Intra- and Inter-Rater Reliability of a New Muscle Strength/Endurance Test Battery for Swedish Soldiers.

    Directory of Open Access Journals (Sweden)

    Helena Larsson

    Full Text Available The objective of this study was to examine the content validity of commonly used muscle performance tests in military personnel and to investigate the reliability of a proposed test battery. For the content validity investigation, thirty selected tests were those described in the literature and/or commonly used in the Nordic and North Atlantic Treaty Organization (NATO countries. Nine selected experts rated, on a four-point Likert scale, the relevance of these tests in relation to five different work tasks: lifting, carrying equipment on the body or in the hands, climbing, and digging. Thereafter, a content validity index (CVI was calculated for each work task. The result showed excellent CVI (≥0.78 for sixteen tests, which comprised of one or more of the military work tasks. Three of the tests; the functional lower-limb loading test (the Ranger test, dead-lift with kettlebells, and back extension, showed excellent content validity for four of the work tasks. For the development of a new muscle strength/endurance test battery, these three tests were further supplemented with two other tests, namely, the chins and side-bridge test. The inter-rater reliability was high (intraclass correlation coefficient, ICC2,1 0.99 for all five tests. The intra-rater reliability was good to high (ICC3,1 0.82-0.96 with an acceptable standard error of mean (SEM, except for the side-bridge test (SEM%>15. Thus, the final suggested test battery for a valid and reliable evaluation of soldiers' muscle performance comprised the following four tests; the Ranger test, dead-lift with kettlebells, chins, and back extension test. The criterion-related validity of the test battery should be further evaluated for soldiers exposed to varying physical workload.

  1. Requirement analysis of testers qualified for aircraft compatibility test x-ray diagnostic and interventional radiology in Indonesia

    International Nuclear Information System (INIS)

    Diah Astuti Indarwati; Haendra Subekti

    2013-01-01

    Analysis of the need of Qualified Tester by calculating the number of test team to perform conformance test of diagnostic and interventional X-ray equipment has been done. This analysis was conducted in order to map the needs of Qualified Testers in Indonesia. As the conformance test certificate will be used in the licensing process, the availability of Tester will greatly affect the continuity and smoothness of the licensing process. The result shows the number of required test team is currently as much as 49 teams, while the availability of the test team is 7 test team. Thus there is still a large gap between the need and availability of the test team to perform conformance test. For the central and eastern of Indonesia on the scope of CT Scan, Mammography, Fluoroscopy and can only be met by tester in Java. (author)

  2. Rapidly Adaptable Instrumentation Tester (RAIT)

    International Nuclear Information System (INIS)

    Vargo, Timothy D.

    1999-01-01

    Emerging technologies in the field of ''Test ampersand Measurement'' have recently enabled the development of the Rapidly Adaptable Instrumentation Tester (RAIT). Based on software developed with LabVIEW, the RAIT design enables quick reconfiguration to test and calibrate a wide variety of telemetry systems. The consequences of inadequate testing could be devastating if a telemetry system were to fail during an expensive flight mission. Supporting both open-bench testing as well as automated test sequences, the RAIT has significantly lowered total time required to test and calibrate a system. This has resulted in an overall lower per unit testing cost than has been achievable in the past

  3. Reliability of reactor materials

    International Nuclear Information System (INIS)

    Toerroenen, K.; Aho-Mantila, I.

    1986-05-01

    This report is the final technical report of the fracture mechanics part of the Reliability of Reactor Materials Programme, which was carried out at the Technical Research Centre of Finland (VTT) through the years 1981 to 1983. Research and development work was carried out in five major areas, viz. statistical treatment and modelling of cleavage fracture, crack arrest, ductile fracture, instrumented impact testing as well as comparison of numerical and experimental elastic-plastic fracture mechanics. In the area of cleavage fracture the critical variables affecting the fracture of steels are considered in the frames of a statistical model, so called WST-model. Comparison of fracture toughness values predicted by the model and corresponding experimental values shows excellent agreement for a variety of microstructures. different posibilities for using the model are discussed. The development work in the area of crack arrest testing was concentrated in the crack starter properties, test arrangement and computer control. A computerized elastic-plastic fracture testing method with a variety of test specimen geometries in a large temperature range was developed for a routine stage. Ductile fracture characteristics of reactor pressure vessel steel A533B and comparable weld material are given. The features of a new, patented instrumented impact tester are described. Experimental and theoretical comparisons between the new and conventional testers indicated clearly the improvements achieved with the new tester. A comparison of numerical and experimental elastic-plastic fracture mechanics capabilities at VTT was carried out. The comparison consisted of two-dimensional linear elastic as well as elastic-plastic finite element analysis of four specimen geometries and equivalent experimental tests. (author)

  4. BurnCase 3D software validation study: Burn size measurement accuracy and inter-rater reliability.

    Science.gov (United States)

    Parvizi, Daryousch; Giretzlehner, Michael; Wurzer, Paul; Klein, Limor Dinur; Shoham, Yaron; Bohanon, Fredrick J; Haller, Herbert L; Tuca, Alexandru; Branski, Ludwik K; Lumenta, David B; Herndon, David N; Kamolz, Lars-P

    2016-03-01

    The aim of this study was to compare the accuracy of burn size estimation using the computer-assisted software BurnCase 3D (RISC Software GmbH, Hagenberg, Austria) with that using a 2D scan, considered to be the actual burn size. Thirty artificial burn areas were pre planned and prepared on three mannequins (one child, one female, and one male). Five trained physicians (raters) were asked to assess the size of all wound areas using BurnCase 3D software. The results were then compared with the real wound areas, as determined by 2D planimetry imaging. To examine inter-rater reliability, we performed an intraclass correlation analysis with a 95% confidence interval. The mean wound area estimations of the five raters using BurnCase 3D were in total 20.7±0.9% for the child, 27.2±1.5% for the female and 16.5±0.1% for the male mannequin. Our analysis showed relative overestimations of 0.4%, 2.8% and 1.5% for the child, female and male mannequins respectively, compared to the 2D scan. The intraclass correlation between the single raters for mean percentage of the artificial burn areas was 98.6%. There was also a high intraclass correlation between the single raters and the 2D Scan visible. BurnCase 3D is a valid and reliable tool for the determination of total body surface area burned in standard models. Further clinical studies including different pediatric and overweight adult mannequins are warranted. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  5. Perform qualify reliability-power tests by shooting common mistakes: practical problems and standard answers per Telcordia/Bellcore requests

    Science.gov (United States)

    Yu, Zheng

    2002-08-01

    Facing the new demands of the optical fiber communications market, almost all the performance and reliability of optical network system are dependent on the qualification of the fiber optics components. So, how to comply with the system requirements, the Telcordia / Bellcore reliability and high-power testing has become the key issue for the fiber optics components manufacturers. The qualification of Telcordia / Bellcore reliability or high-power testing is a crucial issue for the manufacturers. It is relating to who is the outstanding one in the intense competition market. These testing also need maintenances and optimizations. Now, work on the reliability and high-power testing have become the new demands in the market. The way is needed to get the 'Triple-Win' goal expected by the component-makers, the reliability-testers and the system-users. To those who are meeting practical problems for the testing, there are following seven topics that deal with how to shoot the common mistakes to perform qualify reliability and high-power testing: ¸ Qualification maintenance requirements for the reliability testing ¸ Lots control for preparing the reliability testing ¸ Sampling select per the reliability testing ¸ Interim measurements during the reliability testing ¸ Basic referencing factors relating to the high-power testing ¸ Necessity of re-qualification testing for the changing of producing ¸ Understanding the similarity for product family by the definitions

  6. Reliability of radiographic observations recorded on a proforma measured using inter- and intra-observer variation: a preliminary study.

    Science.gov (United States)

    Saunders, M B; Gulabivala, K; Holt, R; Kahan, R S

    2000-05-01

    The aim of this preliminary study was to test the reliability of radiographic evaluation of features of endodontic interest using a newly devised data collection system. Twelve endodontic MSc postgraduate students and one specialist endodontist examined sample radiographs derived from a random selection of 42 patients seen previously on an Endodontic New Patient Clinic (EDI). Each student examined a random selection of 8-9 roots on periapical radiographs of single- and multirooted teeth, with and without previous root canal therapy and 3-4 dental panoramic tomograms (DPTs). A total of 100 roots were examined. A proforma was used to record observations on 67 radiographic features using predefined criteria. Intra-observer agreement was tested by asking the students to re-examine the radiographs. The principle investigator and the specialist endodontist examined the same radiographs and devised a Gold Standard using the same criteria. This was compared with the student assessments to determine inter-observer variation. The postgraduates then attended a revision session on the use of the form. Each student subsequently examined 8-9 different roots from the pool of radiographs. A further assessment of inter-observer variation was made by comparing these observations with the Gold Standard. Of the 67 radiographic features, only 25 had sufficient response to allow statistical analysis. Kappa values for intra- and inter-observer variation were estimated. These varied depending on the particular radiographic feature being assessed. Fifteen out of 25 intra-observer recordings showed 'good' or 'very good' Kappa agreement, but only three out of 25 inter-observer observations achieved 'good' or 'very good' values. Inter-observer variation was improved following the revision session with 16 out of 25 observations achieving 'good' or 'very good' Kappa agreement. Modification to the proforma, the criteria used, and training for radiographic assessment were considered necessary to

  7. Usefulness of new wetness tester for diagnosis of dry mouth in disabled patients.

    Science.gov (United States)

    Kakinoki, Yasuaki; Nishihara, Tatsuji; Arita, Masahiro; Shibuya, Koji; Ishikawa, Masao

    2004-12-01

    The condition of dry mouth is an influential factor in the incidence of caries, periodontal disease, fungal infections, masticatory dysfunctions and denture function. Bedridden elderly and disabled persons often suffer from oral dryness and the aim of this study was to evaluate the usefulness of measuring the amount of moisture in the oral mucosa for clinical diagnosis of dry mouth in this group. The subjects were 20 elderly bedridden individuals, age range 65-89 years old, living in a nursing home and six healthy laboratory researchers, aged 20-46 years old, used as controls. Tongue dorsum moisture measurements were performed using a newly developed wetness tester (L-SALIVO), in which the wet portion was measured after 10 s. Further, clinical diagnosis of dry mouth was carried out using a clinical classification scale of the tongue mucosa (grade range, 0-3). It was possible to measure tongue dorsum moisture in all subjects with the wetness tester. The average moisture value was 0.1+/-0.2 mm in elderly subjects with a dry mouth grade of 2 (n = 8) or 3 (n = 12), while the average moisture value in the control subjects was 3.67+/-1.75 mm with a dry mouth grade of 0 (n = 4) or 1 (n = 2). Tester values and cliniical classification showed a positive co-relationship (r = 0.31, p < 0.05). Our results show that this new tester could be useful for evaluating oral dryness and diagnosing dry mouth.

  8. Software testing an ISTQB-BCS certified tester foundation guide

    CERN Document Server

    Hambling, Brian; Samaroo, Angelina; Thompson, Geoff; Williams, Peter; Hambling, Brian

    2015-01-01

    This practical guide provides insight into software testing, explaining the basics of the testing process and how to perform effective tests. It provides an overview of different techniques and how to apply them. It is the best-selling official textbook of the ISTQB-BCS Certified Tester Foundation Level.

  9. Patient perceptions and expectations of an anticoagulation service: a quantitative comparison study of clinic-based testers and patient self-testers.

    Science.gov (United States)

    Money, Arthur G; Barnett, Julie; Kuljis, Jasna; Duffin, Debbie

    2015-12-01

    Government initiatives see the provision of technology-assisted self-care as one of the key areas in which there is capacity for improving quality of care whilst reducing costs. However, levels of patient engagement in self-testing and management (STM) remain low. Little emphasis has been placed on understanding the patients' perspectives of the reasons for this limited engagement. Typically, patient engagement in STM is achieved via the provision of patient education programmes, which aim to enable patients to make the changes necessary to become competent self-carers. However, placing the onus to change on the individual patient is unrealistic. If levels of patient engagement are to be improved, patient needs and expectations of clinical services must be better understood and service provision must be adapted accordingly. Explore patient perceptions and expectations of clinical service provision and their views of having and making choices about care. Participants [N = 191, 103 patient self-tester managers (PSTMs) and 87 clinic-based testers (CBTs)] completed the SERVQUAL and ChQ instruments to capture perspectives on service quality and choice, respectively. A comparative statistical analysis explored the similarities and differences between PSTMs' and CBTs' responses. Clinic-based testers' perceptions of service quality were significantly more positive than PSTMs', as were their expectations of the 'tangible' aspects of service delivery. PSTMs' expectations of service quality were significantly higher than their perceptions. PSTMs attributed significantly more value to making choices compared with CBTs. To close the gap between PSTMs expectations and perceptions of service quality and better cater for their choice preferences, service providers may benefit from taking into account the following practice considerations: maintain frequent, timely, personalised and direct interactions with PSTMs; prioritise investment in resources to facilitate patient

  10. Relating the octane numbers of fuels to ignition delay times measured in an ignition quality tester (IQT)

    KAUST Repository

    Naser, Nimal; Yang, Seung Yeon; Kalghatgi, Gautam; Chung, Suk-Ho

    2016-01-01

    an ignition quality tester. A baseline data of ignition delay times were determined using an ignition quality tester at a charge pressure of 21.3 bar between 770 and 850 K and an equivalence ratio of 0.7 for various primary reference fuels (PRFs, mixtures

  11. Repeated stimulation, inter-stimulus interval and inter-electrode distance alters muscle contractile properties as measured by Tensiomyography.

    Directory of Open Access Journals (Sweden)

    Hannah V Wilson

    Full Text Available The influence of methodological parameters on the measurement of muscle contractile properties using Tensiomyography (TMG has not been published.To investigate the; (1 reliability of stimulus amplitude needed to elicit maximum muscle displacement (Dm, (2 effect of changing inter-stimulus interval on Dm (using a fixed stimulus amplitude and contraction time (Tc, (3 the effect of changing inter-electrode distance on Dm and Tc.Within subject, repeated measures.10 participants for each objective.Dm and Tc of the rectus femoris, measured using TMG.The coefficient of variance (CV and the intra-class correlation (ICC of stimulus amplitude needed to elicit maximum Dm was 5.7% and 0.92 respectively. Dm was higher when using an inter-electrode distance of 7cm compared to 5cm [P = 0.03] and when using an inter-stimulus interval of 10s compared to 30s [P = 0.017]. Further analysis of inter-stimulus interval data, found that during 10 repeated stimuli Tc became faster after the 5th measure when compared to the second measure [P<0.05]. The 30s inter-stimulus interval produced the most stable Tc over 10 measures compared to 10s and 5s respectively.Our data suggest that the stimulus amplitude producing maximum Dm of the rectus femoris is reliable. Inter-electrode distance and inter-stimulus interval can significantly influence Dm and/ or Tc. Our results support the use of a 30s inter-stimulus interval over 10s or 5s. Future studies should determine the influence of methodological parameters on muscle contractile properties in a range of muscles.

  12. Repeated stimulation, inter-stimulus interval and inter-electrode distance alters muscle contractile properties as measured by Tensiomyography

    Science.gov (United States)

    Johnson, Mark I.; Francis, Peter

    2018-01-01

    Context The influence of methodological parameters on the measurement of muscle contractile properties using Tensiomyography (TMG) has not been published. Objective To investigate the; (1) reliability of stimulus amplitude needed to elicit maximum muscle displacement (Dm), (2) effect of changing inter-stimulus interval on Dm (using a fixed stimulus amplitude) and contraction time (Tc), (3) the effect of changing inter-electrode distance on Dm and Tc. Design Within subject, repeated measures. Participants 10 participants for each objective. Main outcome measures Dm and Tc of the rectus femoris, measured using TMG. Results The coefficient of variance (CV) and the intra-class correlation (ICC) of stimulus amplitude needed to elicit maximum Dm was 5.7% and 0.92 respectively. Dm was higher when using an inter-electrode distance of 7cm compared to 5cm [P = 0.03] and when using an inter-stimulus interval of 10s compared to 30s [P = 0.017]. Further analysis of inter-stimulus interval data, found that during 10 repeated stimuli Tc became faster after the 5th measure when compared to the second measure [P<0.05]. The 30s inter-stimulus interval produced the most stable Tc over 10 measures compared to 10s and 5s respectively. Conclusion Our data suggest that the stimulus amplitude producing maximum Dm of the rectus femoris is reliable. Inter-electrode distance and inter-stimulus interval can significantly influence Dm and/ or Tc. Our results support the use of a 30s inter-stimulus interval over 10s or 5s. Future studies should determine the influence of methodological parameters on muscle contractile properties in a range of muscles. PMID:29451885

  13. Explosive component acceptance tester using laser interferometer technology

    Science.gov (United States)

    Wickstrom, Richard D.; Tarbell, William W.

    1993-01-01

    Acceptance testing of explosive components requires a reliable and simple to use testing method that can discern less than optimal performance. For hot-wire detonators, traditional techniques use dent blocks or photographic diagnostic methods. More complicated approaches are avoided because of their inherent problems with setup and maintenance. A recently developed tester is based on using a laser interferometer to measure the velocity of flying plates accelerated by explosively actuated detonators. Unlike ordinary interferometers that monitor displacement of the test article, this device measures velocity directly and is commonly used with non-spectral surfaces. Most often referred to as the VISAR technique (Velocity Interferometer System for Any Reflecting Surface), it has become the most widely-accepted choice for accurate measurement of velocity in the range greater than 1 mm/micro-s. Traditional VISAR devices require extensive setup and adjustment and therefore are unacceptable in a production-testing environment. This paper describes a new VISAR approach which requires virtually no adjustments, yet provides data with accuracy comparable to the more complicated systems. The device, termed the Fixed-Cavity VISAR, is currently being developed to serve as a product verification tool for hot-wire detonators and slappers. An extensive data acquisition and analysis computer code was also created to automate the manipulation of raw data into final results.

  14. Reliability of Alberta Infant Motor Scale Using Recorded Video Observations Among the Preterm Infants in India: A Reliability Study

    Directory of Open Access Journals (Sweden)

    Veena Kirthika S

    2017-10-01

    Full Text Available Background: Assessment of motor function is a vital characteristic of infant development. Alberta Infant Motor scale (AIMS is considered to be one of the tool available for screening the developmental delays, but this scale was formulated by using western samples. Every country has its own ethnic and cultural background and various differences are observed in the culture and ethnicity. Therefore, there is a need to obtain reliability for the use of AIMS in south Indian population. Purpose: To find the intra-rater and inter-rater reliability of Alberta Infant Motor Scale (AIMS on pre-term infants using the recorded video observations in Indian population. Method: 30 preterm infants in three age groups, 0-3 months (10 infants, 4-7 months (10 infants, 8-18 months (10 infants were recruited for this reliability study. The AIMS was administered to the preterm infants and the performance was videotaped. The performance was then rescored by the same therapist, immediately from the video and on another two consecutive months to estimate intra-rater reliability using ICC (3,1, two-way mixed effects model. For reporting inter-rater reliability, AIMS was scored by three different raters, using ICC (2,k two-way random effects model and by two other therapists to examine the inter and intra-rater reliability. Results: The two-way mixed effects model for intra-rater reliability of AIMS, ICC (3,1 = 0.99 and for reporting inter-rater reliability of AIMS by two-way random effects model, ICC (2,k = 0.96. Conclusion: AIMS has excellent intra and inter-rater reliability using recorded video observations among the preterm infants in India

  15. Modified personal interviews: resurrecting reliable personal interviews for admissions?

    Science.gov (United States)

    Hanson, Mark D; Kulasegaram, Kulamakan Mahan; Woods, Nicole N; Fechtig, Lindsey; Anderson, Geoff

    2012-10-01

    Traditional admissions personal interviews provide flexible faculty-student interactions but are plagued by low inter-interview reliability. Axelson and Kreiter (2009) retrospectively showed that multiple independent sampling (MIS) may improve reliability of personal interviews; thus, the authors incorporated MIS into the admissions process for medical students applying to the University of Toronto's Leadership Education and Development Program (LEAD). They examined the reliability and resource demands of this modified personal interview (MPI) format. In 2010-2011, LEAD candidates submitted written applications, which were used to screen for participation in the MPI process. Selected candidates completed four brief (10-12 minutes) independent MPIs each with a different interviewer. The authors blueprinted MPI questions to (i.e., aligned them with) leadership attributes, and interviewers assessed candidates' eligibility on a five-point Likert-type scale. The authors analyzed inter-interview reliability using the generalizability theory. Sixteen candidates submitted applications; 10 proceeded to the MPI stage. Reliability of the written application components was 0.75. The MPI process had overall inter-interview reliability of 0.79. Correlation between the written application and MPI scores was 0.49. A decision study showed acceptable reliability of 0.74 with only three MPIs scored using one global rating. Furthermore, a traditional admissions interview format would take 66% more time than the MPI format. The MPI format, used during the LEAD admissions process, achieved high reliability with minimal faculty resources. The MPI format's reliability and effective resource use were possible through MIS and employment of expert interviewers. MPIs may be useful for other admissions tasks.

  16. X-real-time executive (X-RTE) an ultra-high reliable real-time executive for safety critical systems

    International Nuclear Information System (INIS)

    Suresh Babu, R.M.

    1995-01-01

    With growing number of application of computers in safety critical systems of nuclear plants there has been a need to assure high quality and reliability of the software used in these systems. One way to assure software quality is to use qualified software components. Since the safety systems and control systems are real-time systems there is a need for a real-time supervisory software to guarantee temporal response of the system. This report describes one such software package, called X-Real-Time Executive (or X-RTE), which was developed in Reactor Control Division, BARC. The report describes all the capabilities and unique features of X-RTE and compares it with a commercially available operating system. The features of X-RTE include pre-emptive scheduling, process synchronization, inter-process communication, multi-processor support, temporal support, debug facility, high portability, high reliability, high quality, and extensive documentation. Examples have been used very liberally to illustrate the underlying concepts. Besides, the report provides a brief description about the methods used, during the software development, to assure high quality and reliability of X-RTE. (author). refs., 11 figs., tabs

  17. Assessment of apraxia: inter-rater reliability of a new apraxia test, association between apraxia and other cognitive deficits and prevalence of apraxia in a rehabilitation setting.

    Science.gov (United States)

    Zwinkels, Angeliek; Geusgens, Chantal; van de Sande, Peter; Van Heugten, Caroline

    2004-11-01

    To investigate the inter-rater reliability of a new apraxia test. Furthermore to examine the association of apraxia with other neuropsychological impairments and the prevalence of apraxia in a rehabilitation setting on the basis of the new test. Cross-sectional cohort study, involving 100 patients with a first stroke admitted to a rehabilitation centre in the Netherlands. General patient characteristics and stroke-related aspects. Cognitive screening involving apraxia, visuospatial scanning, abstract thinking and reasoning, memory, attention, planning and aphasia. The indices for inter-rater agreement range from excellent to poor. Significant correlations are found between apraxia and visuospatial scanning, memory, attention, planning and aphasia. The patients with apraxia perform significantly worse than the patients without apraxia on memory, the time needed to complete the tests for scanning and attention, and aphasia. The prevalence of apraxia is 25.3% in the total group, 51.3% in the left hemisphere stroke patients and 6.0% in the right hemisphere stroke patients. Patients with and without apraxia do not differ significantly concerning age, gender and type of stroke. The apraxia test has been shown to be a reliable instrument. Apraxia is often associated with aphasia, memory problems and mental slowness. This study shows that on the basis of the apraxia test, the prevalence of apraxia among patients in the rehabilitation centre is high, especially among patients with left hemisphere lesions.

  18. 16 CFR Figure 4 to Subpart A of... - Flooring Radiant Panel Tester Schematic Low Flux End, Elevation

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Flooring Radiant Panel Tester Schematic Low Flux End, Elevation 4 Figure 4 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY... Standard Pt. 1209, Subpt. A, Fig. 4 Figure 4 to Subpart A of Part 1209—Flooring Radiant Panel Tester...

  19. Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: useful in research and individual patient settings? A reliability study

    Directory of Open Access Journals (Sweden)

    Koblbauer Ian FH

    2011-10-01

    Full Text Available Abstract Background Patients undergoing total knee arthroplasty (TKA often experience strength deficits both pre- and post-operatively. As these deficits may have a direct impact on functional recovery, strength assessment should be performed in this patient population. For these assessments, reliable measurements should be used. This study aimed to determine the inter- and intrarater reliability of hand-held dynamometry (HHD in measuring isometric knee strength in patients awaiting TKA. Methods To determine interrater reliability, 32 patients (81.3% female were assessed by two examiners. Patients were assessed consecutively by both examiners on the same individual test dates. To determine intrarater reliability, a subgroup (n = 13 was again assessed by the examiners within four weeks of the initial testing procedure. Maximal isometric knee flexor and extensor strength were tested using a modified Citec hand-held dynamometer. Both the affected and unaffected knee were tested. Reliability was assessed using the Intraclass Correlation Coefficient (ICC. In addition, the Standard Error of Measurement (SEM and the Smallest Detectable Difference (SDD were used to determine reliability. Results In both the affected and unaffected knee, the inter- and intrarater reliability were good for knee flexors (ICC range 0.76-0.94 and excellent for knee extensors (ICC range 0.92-0.97. However, measurement error was high, displaying SDD ranges between 21.7% and 36.2% for interrater reliability and between 19.0% and 57.5% for intrarater reliability. Overall, measurement error was higher for the knee flexors than for the knee extensors. Conclusions Modified HHD appears to be a reliable strength measure, producing good to excellent ICC values for both inter- and intrarater reliability in a group of TKA patients. High SEM and SDD values, however, indicate high measurement error for individual measures. This study demonstrates that a modified HHD is appropriate to

  20. Correction of gene expression data: Performance-dependency on inter-replicate and inter-treatment biases.

    Science.gov (United States)

    Darbani, Behrooz; Stewart, C Neal; Noeparvar, Shahin; Borg, Søren

    2014-10-20

    This report investigates for the first time the potential inter-treatment bias source of cell number for gene expression studies. Cell-number bias can affect gene expression analysis when comparing samples with unequal total cellular RNA content or with different RNA extraction efficiencies. For maximal reliability of analysis, therefore, comparisons should be performed at the cellular level. This could be accomplished using an appropriate correction method that can detect and remove the inter-treatment bias for cell-number. Based on inter-treatment variations of reference genes, we introduce an analytical approach to examine the suitability of correction methods by considering the inter-treatment bias as well as the inter-replicate variance, which allows use of the best correction method with minimum residual bias. Analyses of RNA sequencing and microarray data showed that the efficiencies of correction methods are influenced by the inter-treatment bias as well as the inter-replicate variance. Therefore, we recommend inspecting both of the bias sources in order to apply the most efficient correction method. As an alternative correction strategy, sequential application of different correction approaches is also advised. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Intra- and inter-rater reliabilities of measurement of ultrasound imaging for muscle thickness and pennation angle of tibialis anterior muscle in stroke patients.

    Science.gov (United States)

    Cho, Ki Hun; Lee, Hwang Jae; Lee, Wan Hee

    2017-07-01

    Dysfunction of skeletal muscle has been commonly reported in stroke patients. The purpose of this study was to investigate the intra- and inter-rater reliabilities of measurement of ultrasound imaging (USI) for pennation angle (PA) and muscle thickness (MT) of tibialis anterior muscle in stroke patients. Thirty-four stroke patients (19 men) participated in this study. USI was used for measurement of PA and MT of the tibialis anterior muscles at rest and during maximum voluntary contraction (MVC). Two examiners acquired images from all participants during two separate testing sessions, seven days apart. Intra-class correlation coefficients (ICCs), confidence interval (CI), standard error of measurement, minimal detectable change, and Bland-Altman plots were used for estimation of reliability. In the intra-rater reliability between measures, for all variables (PA and MT of the paretic and non-paretic sides of tibialis anterior muscles at rest and during MVC), the ICCs ranged between 0.639 and 0.998 and the CI was within an acceptable range of 0.388-0.999. In inter-rater reliability between examiners for the two tests, for all variables, the ICCs ranged between 0.690 and 0.995 and the CI was within an acceptable range of 0.463-0.997. In addition, significant difference was observed between the paretic and non-paretic sides of the tibialis anterior muscle architecture (p stroke patients. In addition, objective and quantitative measurements of tibialis anterior muscle using USI may provide appropriate management for the walking recovery of stroke patients.

  2. submitter Test strategies for industrial testers for converter controls equipment

    CERN Document Server

    Oleniuk, P; Kasampalis, V; Nisbet, D; Todd, B; Uznański, S

    2017-01-01

    Power converters and their controls electronics are key elements for the operation of the CERN accelerator complex, having a direct impact on its availability. To prevent early-life failures and provide means to verify electronics, a set of industrial testers is used throughout the converters controls electronics' life cycle. The roles of the testers are to validate mass production during the manufacturing phase and to provide means to diagnose and repair failed modules that are brought back from operation. In the converter controls electronics section of the power converters group in the technology department of CERN (TE/EPC/CCE), two main test platforms have been adopted: a PXI platform for mixed analogue-digital functional tests and a JTAG Boundary-Scan platform for digital interconnection and functional tests. Depending on the functionality of the device under test, the appropriate test platforms are chosen. This paper is a follow-up to results presented at the TWEPP 2015 conference, adding the boundary s...

  3. Training less-experienced faculty improves reliability of skills assessment in cardiac surgery.

    Science.gov (United States)

    Lou, Xiaoying; Lee, Richard; Feins, Richard H; Enter, Daniel; Hicks, George L; Verrier, Edward D; Fann, James I

    2014-12-01

    Previous work has demonstrated high inter-rater reliability in the objective assessment of simulated anastomoses among experienced educators. We evaluated the inter-rater reliability of less-experienced educators and the impact of focused training with a video-embedded coronary anastomosis assessment tool. Nine less-experienced cardiothoracic surgery faculty members from different institutions evaluated 2 videos of simulated coronary anastomoses (1 by a medical student and 1 by a resident) at the Thoracic Surgery Directors Association Boot Camp. They then underwent a 30-minute training session using an assessment tool with embedded videos to anchor rating scores for 10 components of coronary artery anastomosis. Afterward, they evaluated 2 videos of a different student and resident performing the task. Components were scored on a 1 to 5 Likert scale, yielding an average composite score. Inter-rater reliabilities of component and composite scores were assessed using intraclass correlation coefficients (ICCs) and overall pass/fail ratings with kappa. All components of the assessment tool exhibited improvement in reliability, with 4 (bite, needle holder use, needle angles, and hand mechanics) improving the most from poor (ICC range, 0.09-0.48) to strong (ICC range, 0.80-0.90) agreement. After training, inter-rater reliabilities for composite scores improved from moderate (ICC, 0.76) to strong (ICC, 0.90) agreement, and for overall pass/fail ratings, from poor (kappa = 0.20) to moderate (kappa = 0.78) agreement. Focused, video-based anchor training facilitates greater inter-rater reliability in the objective assessment of simulated coronary anastomoses. Among raters with less teaching experience, such training may be needed before objective evaluation of technical skills. Published by Elsevier Inc.

  4. Reproducibility of tender point examination in chronic low back pain patients as measured by intrarater and inter-rater reliability and agreement

    DEFF Research Database (Denmark)

    Jensen, Ole Kudsk; Callesen, Jacob; Nielsen, Merete Graakjaer

    2013-01-01

    back examination and return-to-work intervention, 43 and 39 patients, respectively (18 women, 46%) entered and completed the study. MAIN OUTCOME MEASURES: The reliability was estimated by the intraclass correlation coefficient (ICC), and agreement was calculated for up to ±3 TPs. Furthermore......, the smallest detectable difference was calculated. RESULTS: TP examination was performed twice by two consultants in rheumatology and rehabilitation at 20 min intervals and repeated 1 week later. Intrarater reliability in the more and less experienced rater was ICC 0.84 (95% CI 0.69 to 0.98) and 0.72 (95% CI 0.......49 to 0.95), respectively. The figures for inter-rater reliability were intermediate between these figures. In more than 70% of the cases, the raters agreed within ±3 TPs in both men and women and between test days. The smallest detectable difference between raters was 5, and for the more and less...

  5. The Pooling-score (P-score): inter- and intra-rater reliability in endoscopic assessment of the severity of dysphagia.

    Science.gov (United States)

    Farneti, D; Fattori, B; Nacci, A; Mancini, V; Simonelli, M; Ruoppolo, G; Genovese, E

    2014-04-01

    This study evaluated the intra- and inter-rater reliability of the Pooling score (P-score) in clinical endoscopic evaluation of severity of swallowing disorder, considering excess residue in the pharynx and larynx. The score (minimum 4 - maximum 11) is obtained by the sum of the scores given to the site of the bolus, the amount and ability to control residue/bolus pooling, the latter assessed on the basis of cough, raclage, number of dry voluntary or reflex swallowing acts ( 5). Four judges evaluated 30 short films of pharyngeal transit of 10 solid (1/4 of a cracker), 11 creamy (1 tablespoon of jam) and 9 liquid (1 tablespoon of 5 cc of water coloured with methlyene blue, 1 ml in 100 ml) boluses in 23 subjects (10 M/13 F, age from 31 to 76 yrs, mean age 58.56±11.76 years) with different pathologies. The films were randomly distributed on two CDs, which differed in terms of the sequence of the films, and were given to judges (after an explanatory session) at time 0, 24 hours later (time 1) and after 7 days (time 2). The inter- and intra-rater reliability of the P-score was calculated using the intra-class correlation coefficient (ICC; 3,k). The possibility that consistency of boluses could affect the scoring of the films was considered. The ICC for site, amount, management and the P-score total was found to be, respectively, 0.999, 0.997, 1.00 and 0.999. Clinical evaluation of a criterion of severity of a swallowing disorder remains a crucial point in the management of patients with pathologies that predispose to complications. The P-score, derived from static and dynamic parameters, yielded a very high correlation among the scores attributed by the four judges during observations carried out at different times. Bolus consistencies did not affect the outcome of the test: the analysis of variance, performed to verify if the scores attributed by the four judges to the parameters selected, might be influenced by the different consistencies of the boluses, was not

  6. How to assess and compare inter-rater reliability, agreement and correlation of ratings: an exemplary analysis of mother-father and parent-teacher expressive vocabulary rating pairs.

    Science.gov (United States)

    Stolarova, Margarita; Wolf, Corinna; Rinker, Tanja; Brielmann, Aenne

    2014-01-01

    This report has two main purposes. First, we combine well-known analytical approaches to conduct a comprehensive assessment of agreement and correlation of rating-pairs and to dis-entangle these often confused concepts, providing a best-practice example on concrete data and a tutorial for future reference. Second, we explore whether a screening questionnaire developed for use with parents can be reliably employed with daycare teachers when assessing early expressive vocabulary. A total of 53 vocabulary rating pairs (34 parent-teacher and 19 mother-father pairs) collected for two-year-old children (12 bilingual) are evaluated. First, inter-rater reliability both within and across subgroups is assessed using the intra-class correlation coefficient (ICC). Next, based on this analysis of reliability and on the test-retest reliability of the employed tool, inter-rater agreement is analyzed, magnitude and direction of rating differences are considered. Finally, Pearson correlation coefficients of standardized vocabulary scores are calculated and compared across subgroups. The results underline the necessity to distinguish between reliability measures, agreement and correlation. They also demonstrate the impact of the employed reliability on agreement evaluations. This study provides evidence that parent-teacher ratings of children's early vocabulary can achieve agreement and correlation comparable to those of mother-father ratings on the assessed vocabulary scale. Bilingualism of the evaluated child decreased the likelihood of raters' agreement. We conclude that future reports of agreement, correlation and reliability of ratings will benefit from better definition of terms and stricter methodological approaches. The methodological tutorial provided here holds the potential to increase comparability across empirical reports and can help improve research practices and knowledge transfer to educational and therapeutic settings.

  7. How to assess and compare inter-rater reliability, agreement and correlation of ratings: an exemplary analysis of mother-father and parent-teacher expressive vocabulary rating pairs

    Science.gov (United States)

    Stolarova, Margarita; Wolf, Corinna; Rinker, Tanja; Brielmann, Aenne

    2014-01-01

    This report has two main purposes. First, we combine well-known analytical approaches to conduct a comprehensive assessment of agreement and correlation of rating-pairs and to dis-entangle these often confused concepts, providing a best-practice example on concrete data and a tutorial for future reference. Second, we explore whether a screening questionnaire developed for use with parents can be reliably employed with daycare teachers when assessing early expressive vocabulary. A total of 53 vocabulary rating pairs (34 parent–teacher and 19 mother–father pairs) collected for two-year-old children (12 bilingual) are evaluated. First, inter-rater reliability both within and across subgroups is assessed using the intra-class correlation coefficient (ICC). Next, based on this analysis of reliability and on the test-retest reliability of the employed tool, inter-rater agreement is analyzed, magnitude and direction of rating differences are considered. Finally, Pearson correlation coefficients of standardized vocabulary scores are calculated and compared across subgroups. The results underline the necessity to distinguish between reliability measures, agreement and correlation. They also demonstrate the impact of the employed reliability on agreement evaluations. This study provides evidence that parent–teacher ratings of children's early vocabulary can achieve agreement and correlation comparable to those of mother–father ratings on the assessed vocabulary scale. Bilingualism of the evaluated child decreased the likelihood of raters' agreement. We conclude that future reports of agreement, correlation and reliability of ratings will benefit from better definition of terms and stricter methodological approaches. The methodological tutorial provided here holds the potential to increase comparability across empirical reports and can help improve research practices and knowledge transfer to educational and therapeutic settings. PMID:24994985

  8. Tester Detects Steady-Short Or Intermittent-Open Circuits

    Science.gov (United States)

    Anderson, Bobby L.

    1990-01-01

    Momentary open circuits or steady short circuits trigger buzzer. Simple, portable, lightweight testing circuit sounds long-duration alarm when it detects steady short circuit or momentary open circuit in coaxial cable or other two-conductor transmission line. Tester sensitive to discontinuities lasting 10 microseconds or longer. Used extensively for detecting intermittent open shorts in accelerometer and extensometer cables. Also used as ordinary buzzer-type continuity checker to detect steady short or open circuits.

  9. Intra- and inter-observer agreement and reliability of bone mineral density measurements around acetabular cup

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder; Overgaard, Soren; Torfing, Trine

    2017-01-01

    in measuring bone density (BMD) in complex anatomic structures which might be overcome using dual-energy computed tomography (DECT).PurposeTo test inter- and intra-observer agreement and reliability of in-house segmentation software measuring BMD adjacent to acetabular cup and to compare measurements performed...... with single-energy CT (SECT) and DECT in cemented and cementless cups.Material and Methods: Twenty-four acetabular cups inserted in porcine hip specimens were scanned with SECT and DECT. Bone density was measured in a three-dimensional volume adjacent to the cup. Double measurements were performed.......Results: BMD derived from SECT was approximately four times higher than that of DECT. In both scan modes, intraclass correlation coefficient (ICC) was >0.90 with no differences between repeated measurements, except for uncemented cups where a statistically significant difference of 11 mg/cm3 was found...

  10. Inter- and Intrarater Reliability Using Different Software Versions of E4D Compare in Dental Education.

    Science.gov (United States)

    Callan, Richard S; Cooper, Jeril R; Young, Nancy B; Mollica, Anthony G; Furness, Alan R; Looney, Stephen W

    2015-06-01

    The problems associated with intra- and interexaminer reliability when assessing preclinical performance continue to hinder dental educators' ability to provide accurate and meaningful feedback to students. Many studies have been conducted to evaluate the validity of utilizing various technologies to assist educators in achieving that goal. The purpose of this study was to compare two different versions of E4D Compare software to determine if either could be expected to deliver consistent and reliable comparative results, independent of the individual utilizing the technology. Five faculty members obtained E4D digital images of students' attempts (sample model) at ideal gold crown preparations for tooth #30 performed on typodont teeth. These images were compared to an ideal (master model) preparation utilizing two versions of E4D Compare software. The percent correlations between and within these faculty members were recorded and averaged. The intraclass correlation coefficient was used to measure both inter- and intrarater agreement among the examiners. The study found that using the older version of E4D Compare did not result in acceptable intra- or interrater agreement among the examiners. However, the newer version of E4D Compare, when combined with the Nevo scanner, resulted in a remarkable degree of agreement both between and within the examiners. These results suggest that consistent and reliable results can be expected when utilizing this technology under the protocol described in this study.

  11. Microprocessor tester for the treat upgrade reactor trip system

    International Nuclear Information System (INIS)

    Lenkszus, F.R.; Bucher, R.G.

    1984-01-01

    The upgrading of the Transient Reactor Test (TREAT) Facility at ANL-Idaho has been designed to provide additional experimental capabilities for the study of core disruptive accident (CDA) phenomena. In addition, a programmable Automated Reactor Control System (ARCS) will permit high-power transients up to 11,000 MW having a controlled reactor period of from 15 to 0.1 sec. These modifications to the core neutronics will improve simulation of LMFBR accident conditions. Finally, a sophisticated, multiply-redundant safety system, the Reactor Trip System (RTS), will provide safe operation for both steady state and transient production operating modes. To insure that this complex safety system is functioning properly, a Dedicated Microprocessor Tester (DMT) has been implemented to perform a thorough checkout of the RTS prior to all TREAT operations

  12. Pneumothorax size measurements on digital chest radiographs: Intra- and inter- rater reliability.

    Science.gov (United States)

    Thelle, Andreas; Gjerdevik, Miriam; Grydeland, Thomas; Skorge, Trude D; Wentzel-Larsen, Tore; Bakke, Per S

    2015-10-01

    Detailed and reliable methods may be important for discussions on the importance of pneumothorax size in clinical decision-making. Rhea's method is widely used to estimate pneumothorax size in percent based on chest X-rays (CXRs) from three measure points. Choi's addendum is used for anterioposterior projections. The aim of this study was to examine the intrarater and interrater reliability of the Rhea and Choi method using digital CXR in the ward based PACS monitors. Three physicians examined a retrospective series of 80 digital CXRs showing pneumothorax, using Rhea and Choi's method, then repeated in a random order two weeks later. We used the analysis of variance technique by Eliasziw et al. to assess the intrarater and interrater reliability in altogether 480 estimations of pneumothorax size. Estimated pneumothorax sizes ranged between 5% and 100%. The intrarater reliability coefficient was 0.98 (95% one-sided lower-limit confidence interval C 0.96), and the interrater reliability coefficient was 0.95 (95% one-sided lower-limit confidence interval 0.93). This study has shown that the Rhea and Choi method for calculating pneumothorax size has high intrarater and interrater reliability. These results are valid across gender, side of pneumothorax and whether the patient is diagnosed with primary or secondary pneumothorax. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. Lower limb spasticity assessment using an inertial sensor: a reliability study

    International Nuclear Information System (INIS)

    Sterpi, I; Colombo, R; Caroli, A; Meazza, E; Maggioni, G; Pistarini, C

    2013-01-01

    Spasticity is a common motor impairment in patients with neurological disorders that can prevent functional recovery after rehabilitation. In the clinical setting, its assessment is carried out using standardized clinical scales. The aim of this study was to verify the applicability of inertial sensors for an objective measurement of quadriceps spasticity and evaluate its test–retest and inter-rater reliability during the implementation of the Wartenberg pendulum test. Ten healthy subjects and 11 patients in vegetative state with severe brain damage were enrolled in this study. Subjects were evaluated three times on three consecutive days. The test–retest reliability of measurement was assessed in the first two days. The third day was devoted to inter-rater reliability assessment. In addition, the lower limb muscle tone was bilaterally evaluated at the knee joint by the modified Ashworth scale. The factorial ANOVA analysis showed that the implemented method allowed us to discriminate between healthy and pathological conditions. The fairly low SEM and high ICC values obtained for the pendulum parameters indicated a good test–retest and inter-rater reliability of measurement. This study shows that an inertial sensor can be reliably used to characterize leg kinematics during the Wartenberg pendulum test and provide quantitative evaluation of quadriceps spasticity. (paper)

  14. Combining Ability in Wheat for Seedling Traits by Line X Tester Analysis Under Saline Conditions

    Directory of Open Access Journals (Sweden)

    Muhammad Osaf

    Full Text Available A line × tester analysis involving five varieties SQ-26, SQ-77, GH-10, 8670, PARC-N2 (lines and three varieties 8721, SARC-5 and DN-4 (testers were crossed to study some hydroponics growing characters. In controlled conditions SQ-26 exhibited the highest positive GCA effects on Shoot length, Shoot fresh weight, Na+ and K+ concentrations, while SQ-77 showed maximum GCA effects on Root length, Root fresh weight and Shoot dry weight in females and in males and both DN-4 and SARC-5 showed the highest GCA effects. Under high saline concentration female SQ-77 showed the maximum positive effects on all characters but on shoot length and Na concentration while male SARC-5 exhibited the highest positive GCA effects on all characters. Under high saline level, the cross combination SQ-26 × 8721 showed SCA effects for shoot length, whereas 8670 x 8721 showed the same effects for shoot fresh weight, root fresh weight and root dry weight. For Na+ and K+ concentrations, the cross combination GH-10 × DN-4 showed then highest SCA effects, whereas for shoot dry weight and root length, the cross combinations GH-10 × SARC-5 and PARC-N2 × 8721 showed the highest SCA effects, respectively.

  15. Analysis and Comparison of Thickness and Bending Measurements from Fabric Touch Tester (FTT and Standard Methods

    Directory of Open Access Journals (Sweden)

    Musa Atiyyah Binti Haji

    2018-03-01

    Full Text Available Fabric Touch Tester (FTT is a relatively new device from SDL Atlas to determine touch properties of fabrics. It simultaneously measures 13 touch-related fabric physical properties in four modules that include bending and thickness measurements. This study aims to comparatively analyze the thickness and bending measurements made by the FTT and the common standard methods used in the textile industry. The results obtained with the FTT for 11 different fabrics were compared with that of standard methods. Despite the different measurement principle, a good correlation was found between the two methods used for the assessment of thickness and bending. As FTT is a new tool for textile comfort measurement and no standard yet exists, these findings are essential to determine the reliability of the measurements and how they relate to the well-established standard methods.

  16. Inter-rater Reliability for Metrics Scored in a Binary Fashion-Performance Assessment for an Arthroscopic Bankart Repair.

    Science.gov (United States)

    Gallagher, Anthony G; Ryu, Richard K N; Pedowitz, Robert A; Henn, Patrick; Angelo, Richard L

    2018-05-02

    To determine the inter-rater reliability (IRR) of a procedure-specific checklist scored in a binary fashion for the evaluation of surgical skill and whether it meets a minimum level of agreement (≥0.8 between 2 raters) required for high-stakes assessment. In a prospective randomized and blinded fashion, and after detailed assessment training, 10 Arthroscopy Association of North America Master/Associate Master faculty arthroscopic surgeons (in 5 pairs) with an average of 21 years of surgical experience assessed the video-recorded 3-anchor arthroscopic Bankart repair performance of 44 postgraduate year 4 or 5 residents from 21 Accreditation Council for Graduate Medical Education orthopaedic residency training programs from across the United States. No paired scores of resident surgeon performance evaluated by the 5 teams of faculty assessors dropped below the 0.8 IRR level (mean = 0.93; range 0.84-0.99; standard deviation = 0.035). A comparison between the 5 assessor groups with 1 factor analysis of variance showed that there was no significant difference between the groups (P = .205). Pearson's product-moment correlation coefficient revealed a strong and statistically significant negative correlation, that is, -0.856 (P fashion meet the need and can show a high (>80%) IRR. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. Exact reliability quantification of highly reliable systems with maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Bris, Radim, E-mail: radim.bris@vsb.c [VSB-Technical University Ostrava, Faculty of Electrical Engineering and Computer Science, Department of Applied Mathematics, 17. listopadu 15, 70833 Ostrava-Poruba (Czech Republic)

    2010-12-15

    When a system is composed of highly reliable elements, exact reliability quantification may be problematic, because computer accuracy is limited. Inaccuracy can be due to different aspects. For example, an error may be made when subtracting two numbers that are very close to each other, or at the process of summation of many very different numbers, etc. The basic objective of this paper is to find a procedure, which eliminates errors made by PC when calculations close to an error limit are executed. Highly reliable system is represented by the use of directed acyclic graph which is composed from terminal nodes, i.e. highly reliable input elements, internal nodes representing subsystems and edges that bind all of these nodes. Three admissible unavailability models of terminal nodes are introduced, including both corrective and preventive maintenance. The algorithm for exact unavailability calculation of terminal nodes is based on merits of a high-performance language for technical computing MATLAB. System unavailability quantification procedure applied to a graph structure, which considers both independent and dependent (i.e. repeatedly occurring) terminal nodes is based on combinatorial principle. This principle requires summation of a lot of very different non-negative numbers, which may be a source of an inaccuracy. That is why another algorithm for exact summation of such numbers is designed in the paper. The summation procedure uses benefits from a special number system with the base represented by the value 2{sup 32}. Computational efficiency of the new computing methodology is compared with advanced simulation software. Various calculations on systems from references are performed to emphasize merits of the methodology.

  18. How to assess and compare inter-rater reliability, agreement and correlation of ratings: an exemplary analysis of mother-father and parent-teacher expressive vocabulary rating pairs

    Directory of Open Access Journals (Sweden)

    Margarita eStolarova

    2014-06-01

    Full Text Available This report has two main purposes. First, we combine well-known analytical approaches to conduct a comprehensive assessment of agreement and correlation of rating-pairs and to dis-entangle these often confused concepts, providing a best-practice example on concrete data and a tutorial for future reference. Second, we explore whether a screening questionnaire deve-loped for use with parents can be reliably employed with daycare teachers when assessing early expressive vocabulary. A total of 53 vocabulary rating pairs (34 parent-teacher and 19 mother-father pairs collected for two-year-old children (12 bilingual are evaluated. First, inter-rater reliability both within and across subgroups is assessed using the intra-class correlation coefficient (ICC. Next, based on this analysis of reliability and on the test-retest reliability of the employed tool, inter-rater agreement is analyzed, magnitude and direction of rating differences are considered. Finally, Pearson correlation coefficients of standardized vocabulary scores are calculated and compared across subgroups. The results underline the necessity to distinguish between reliability measures, agreement and correlation. They also demonstrate the impact of the employed reliability on agreement evaluations. This study provides evidence that parent-teacher ratings of children’s early vocabulary can achieve agreement and correlation comparable to those of mother-father ratings on the assessed vocabulary scale. Bilingualism of the evaluated child decreased the likelihood of raters’ agreement. We conclude that future reports of agree-ment, correlation and reliability of ratings will benefit from better definition of terms and stricter methodological approaches. The methodological tutorial provided here holds the potential to increase comparability across empirical reports and can help improve research practices and knowledge transfer to educational and therapeutic settings.

  19. The reliability and validity of the Turkish version of Fullerton Advanced Balance (FAB-T) scale.

    Science.gov (United States)

    Iyigun, Gozde; Kirmizigil, Berkiye; Angin, Ender; Oksuz, Sevim; Can, Filiz; Eker, Levent; Rose, Debra J

    2018-06-04

    The aim of this study was to evaluate the reliability and validity of the Turkish version of the FAB(FAB-T) scale in the older Turkish adults. The reliability and validity of the scale was tested on 200 community-dwelling older adults. FAB-T scale was scored by different physiotherapists on different days to evaluate inter-rater and intrarater reliability. The Berg Balance Scale (BBS) was used for the evaluation of convergent validity, and the content validity of the FAB-T scale was investigated. The FAB-T scale showed very high inter- and intra-rater reliability. For inter-rater agreement, on the individual test items and total score ICC values were 0.92 (95 %CI; 0.90-0.94) and 0.96 (95% CI; 0.95-0.97) respectively. The intra-rater agreement, on the individual test items and total score ICC values were 0.93 (95 %CI; 0.91- 0.95) and 0.96 (95% CI; 0.95- 0.97) respectively. There was a good agreement between the FAB-T and BBS scales. A high correlation was found between the BBS and FAB-T scales [rho = 0.70 (%95 CI; 0.62-0.76)] indicating good convergent validity. Considering the content validity of the FAB-T scale, no floor (floor score: 0%) or ceiling (ceiling score: 6.5%) effect was detected. The FAB-T scale was successfully translated from the original English version (FAB) and demonstrated strong psychometric features. It was found that the FAB-T scale has very high inter-rater and intra-rater reliability. Considering the convergent validity, the scale has high correlation with the BBS. The FAB-T has no floor and ceiling effect. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. The reliability of four widely used patellar height ratios.

    Science.gov (United States)

    van Duijvenbode, Dennis; Stavenuiter, Michel; Burger, Bart; van Dijke, Cees; Spermon, Jacco; Hoozemans, Marco

    2016-03-01

    The objective of this study was to evaluate the inter-observer reliability and the intra-observer reliability of four patellar height ratios: Insall-Salvati (IS), modified Insall-Salvati (MIS), Blackburne-Peel (BP) and Caton-Deschamps (CD). The patellar height ratios were assessed by four independent examiners using weight-bearing lateral knee radiographs in 30° flexion. Intra-class correlation coefficients and Fleiss' kappa's were determined. The inter-observer reliability was excellent for the IS and moderate for the other ratios. When the ratio values were categorized, the inter-observer reliability was strong for the IS, moderate for the MIS and BP, and poor for the CD. The intra-observer reliability was excellent for the IS, MIS and CD, and strong for the BP. When the ratio values were categorized, the intra-observer reliability was strong for the IS and MIS, and moderate for the other ratios. Although the IS showed best reliability, we advise to use the MIS as it showed the second best reliability but is, according to the literature, associated with better validity.

  1. Blinded Comparison between an In-Air Reverberation Method and an Electronic Probe Tester in the Detection of Ultrasound Probe Faults.

    Science.gov (United States)

    Dudley, Nicholas J; Woolley, Darren J

    2017-12-01

    The aim of this study was to perform a blinded trial, comparing the results of a visual inspection of the in-air reverberation pattern with the results of an electronic probe tester in detecting ultrasound probe faults. Sixty-two probes were tested. A total of 28 faults were found, 3 only by in-air reverberation assessment and 2 only by the electronic probe tester. The electronic probe tester provided additional information regarding the location of the fault in 74% of the cases in which both methods detected a fault. It is possible to detect the majority of probe faults by visual inspection and in-air reverberation assessment. The latter provides an excellent first-line test, easily performed on a daily basis by equipment users. An electronic probe tester is required if detailed evaluation of faults is necessary. Copyright © 2017 World Federation for Ultrasound in Medicine and Biology. All rights reserved.

  2. Reliability of one-repetition maximum performance in people with chronic heart failure.

    Science.gov (United States)

    Ellis, Rachel; Holland, Anne E; Dodd, Karen; Shields, Nora

    2018-02-24

    Evaluate intra-rater and inter-rater reliability of the one-repetition maximum strength test in people with chronic heart failure. Intra-rater and inter-rater reliability study. A public tertiary hospital in northern metropolitan Melbourne. Twenty-four participants (nine female, mean age 71.8 ± 13.1 years) with mild to moderate heart failure of any aetiology. Lower limb strength was assessed by determining the maximum weight that could be lifted using a leg press. Intra-rater reliability was tested by one assessor on two separate occasions . Inter-rater reliability was tested by two assessors in random order. Intra-class correlation coefficients and 95% confidence intervals were calculated. Bland and Altman analyses were also conducted, including calculation of mean differences between measures ([Formula: see text]) and limits of agreement . Ten intra-rater and 21 inter-rater assessments were completed. Excellent intra-rater (intra-class correlation coefficient 2,1 0.96) and inter-rater (intra-class correlation coefficient 2,1 0.93) reliability was found. Intra-rater assessment showed less variability (mean difference 4.5 kg, limits of agreement -8.11 to 17.11 kg) than inter-rater agreement (mean difference -3.81 kg, limits of agreement -23.39 to 15.77 kg). One-repetition maximum determined using a leg press is a reliable measure in people with heart failure. Given its smaller limits of agreement, intra-rater testing is recommended. Implications for Rehabilitation Using a leg press to determine a one-repetition maximum we were able to demonstrate excellent inter-rater and intra-rater reliability using an intra-class correlation coefficient. The Bland and Altman levels of agreement were wide for inter-rater reliability and so we recommend using one assessor if measuring change in strength within an individual over time.

  3. Segmental Musculoskeletal Examinations using Dual-Energy X-Ray Absorptiometry (DXA: Positioning and Analysis Considerations

    Directory of Open Access Journals (Sweden)

    Nicolas H. Hart, Sophia Nimphius, Tania Spiteri, Jodie L. Cochrane, Robert U. Newton

    2015-09-01

    Full Text Available Musculoskeletal examinations provide informative and valuable quantitative insight into muscle and bone health. DXA is one mainstream tool used to accurately and reliably determine body composition components and bone mass characteristics in-vivo. Presently, whole body scan models separate the body into axial and appendicular regions, however there is a need for localised appendicular segmentation models to further examine regions of interest within the upper and lower extremities. Similarly, inconsistencies pertaining to patient positioning exist in the literature which influence measurement precision and analysis outcomes highlighting a need for standardised procedure. This paper provides standardised and reproducible: 1 positioning and analysis procedures using DXA and 2 reliable segmental examinations through descriptive appendicular boundaries. Whole-body scans were performed on forty-six (n = 46 football athletes (age: 22.9 ± 4.3 yrs; height: 1.85 ± 0.07 cm; weight: 87.4 ± 10.3 kg; body fat: 11.4 ± 4.5 % using DXA. All segments across all scans were analysed three times by the main investigator on three separate days, and by three independent investigators a week following the original analysis. To examine intra-rater and inter-rater, between day and researcher reliability, coefficients of variation (CV and intraclass correlation coefficients (ICC were determined. Positioning and segmental analysis procedures presented in this study produced very high, nearly perfect intra-tester (CV ≤ 2.0%; ICC ≥ 0.988 and inter-tester (CV ≤ 2.4%; ICC ≥ 0.980 reliability, demonstrating excellent reproducibility within and between practitioners. Standardised examinations of axial and appendicular segments are necessary. Future studies aiming to quantify and report segmental analyses of the upper- and lower-body musculoskeletal properties using whole-body DXA scans are encouraged to use the patient positioning and image analysis procedures

  4. High-Reliability Health Care: Getting There from Here

    Science.gov (United States)

    Chassin, Mark R; Loeb, Jerod M

    2013-01-01

    Context Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer “project fatigue” because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. Methods We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals’ readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. Findings We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Conclusions Hospitals can make substantial progress toward high reliability by undertaking several specific

  5. Supersonic shear imaging provides a reliable measurement of resting muscle shear elastic modulus

    International Nuclear Information System (INIS)

    Lacourpaille, Lilian; Hug, François; Bouillard, Killian; Nordez, Antoine; Hogrel, Jean-Yves

    2012-01-01

    The aim of the present study was to assess the reliability of shear elastic modulus measurements performed using supersonic shear imaging (SSI) in nine resting muscles (i.e. gastrocnemius medialis, tibialis anterior, vastus lateralis, rectus femoris, triceps brachii, biceps brachii, brachioradialis, adductor pollicis obliquus and abductor digiti minimi) of different architectures and typologies. Thirty healthy subjects were randomly assigned to the intra-session reliability (n = 20), inter-day reliability (n = 21) and the inter-observer reliability (n = 16) experiments. Muscle shear elastic modulus ranged from 2.99 (gastrocnemius medialis) to 4.50 kPa (adductor digiti minimi and tibialis anterior). On the whole, very good reliability was observed, with a coefficient of variation (CV) ranging from 4.6% to 8%, except for the inter-operator reliability of adductor pollicis obliquus (CV = 11.5%). The intraclass correlation coefficients were good (0.871 ± 0.045 for the intra-session reliability, 0.815 ± 0.065 for the inter-day reliability and 0.709 ± 0.141 for the inter-observer reliability). Both the reliability and the ease of use of SSI make it a potentially interesting technique that would be of benefit to fundamental, applied and clinical research projects that need an accurate assessment of muscle mechanical properties. (note)

  6. Inter-observer reliability of animal-based welfare indicators included in the Animal Welfare Indicators welfare assessment protocol for dairy goats.

    Science.gov (United States)

    Vieira, A; Battini, M; Can, E; Mattiello, S; Stilwell, G

    2018-01-08

    This study was conducted within the context of the Animal Welfare Indicators (AWIN) project and the underlying scientific motivation for the development of the study was the scarcity of data regarding inter-observer reliability (IOR) of welfare indicators, particularly given the importance of reliability as a further step for developing on-farm welfare assessment protocols. The objective of this study is therefore to evaluate IOR of animal-based indicators (at group and individual-level) of the AWIN welfare assessment protocol (prototype) for dairy goats. In the design of the study, two pairs of observers, one in Portugal and another in Italy, visited 10 farms each and applied the AWIN prototype protocol. Farms in both countries were visited between January and March 2014, and all the observers received the same training before the farm visits were initiated. Data collected during farm visits, and analysed in this study, include group-level and individual-level observations. The results of our study allow us to conclude that most of the group-level indicators presented the highest IOR level ('substantial', 0.85 to 0.99) in both field studies, pointing to a usable set of animal-based welfare indicators that were therefore included in the first level of the final AWIN welfare assessment protocol for dairy goats. Inter-observer reliability of individual-level indicators was lower, but the majority of them still reached 'fair to good' (0.41 to 0.75) and 'excellent' (0.76 to 1) levels. In the paper we explore reasons for the differences found in IOR between the group and individual-level indicators, including how the number of individual-level indicators to be assessed on each animal and the restraining method may have affected the results. Furthermore, we discuss the differences found in the IOR of individual-level indicators in both countries: the Portuguese pair of observers reached a higher level of IOR, when compared with the Italian observers. We argue how the

  7. Intra- and interobserver reliability of glenoid fracture classifications by Ideberg, Euler and AO.

    Science.gov (United States)

    Gilbert, F; Eden, L; Meffert, R; Konietschke, F; Lotz, J; Bauer, L; Staab, W

    2018-03-27

    Representing 3%-5% of shoulder girdle injuries scapula fractures are rare. Furthermore, approximately 1% of scapula fractures are intraarticularfractures of the glenoid fossa. Because of uncertain fracture morphology and limited experience, the treatment of glenoid fossa fractures is difficult. The glenoid fracture classification by Ideberg (1984) and Euler (1996) is still commonly used in literature. In 2013 a new glenoid fracture classification was introduced by the AO. The purpose of this study was to examine the new AO classification in clinical practice in comparison with the classifications by Ideberg and Euler. In total CT images of 84 patients with glenoid fossa fractures from 2005 to 2018 were included. Parasagittal, paracoronary and axial reconstructions were examined according to the classifications of Ideberg, Euler and the AO by 3 investigators (orthopedic surgeon, radiologist, student of medicine) at three individual time settings. Inter- and intraobserver reliability of the three classification systems were ascertained by computing Inter- and Intraclass (ICCs) correlation coefficients using Spearman's rank correlation coefficient, 95%-confidence intervals as well as F-tests for correlation coefficients. Inter- and intraobserver reliability for the AO classification showed a perspicuous coherence (R = 0.74 and R = 0.79). Low to moderate intraobserver reliability for Ideberg (R = 0.46) and Euler classification (R = 0.41) was found. Furthermore, data show a low Interobserver reliability for both Ideberg and Euler classification (R reliability using AO is significantly higher than those using Ideberg and Euler (p reliable grading of glenoid fossa fractures with high inter- and intraobserver reliability in 84 patients using CT images. It should possibly be applied in order to enable a valid, reliable and consistent academic description of glenoid fossa fractures. The established classifications by Euler and Ideberg are not capable of

  8. Reliability of ultrasound thickness measurement of the abdominal muscles during clinical isometric endurance tests.

    Science.gov (United States)

    ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda

    2015-07-01

    The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Reliability of physical examination tests for the diagnosis of knee disorders: Evidence from a systematic review.

    Science.gov (United States)

    Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Desmeules, François

    2016-12-01

    Clinicians often rely on physical examination tests to guide them in the diagnostic process of knee disorders. However, reliability of these tests is often overlooked and may influence the consistency of results and overall diagnostic validity. Therefore, the objective of this study was to systematically review evidence on the reliability of physical examination tests for the diagnosis of knee disorders. A structured literature search was conducted in databases up to January 2016. Included studies needed to report reliability measures of at least one physical test for any knee disorder. Methodological quality was evaluated using the QAREL checklist. A qualitative synthesis of the evidence was performed. Thirty-three studies were included with a mean QAREL score of 5.5 ± 0.5. Based on low to moderate quality evidence, the Thessaly test for meniscal injuries reached moderate inter-rater reliability (k = 0.54). Based on moderate to excellent quality evidence, the Lachman for anterior cruciate ligament injuries reached moderate to excellent inter-rater reliability (k = 0.42 to 0.81). Based on low to moderate quality evidence, the Tibiofemoral Crepitus, Joint Line and Patellofemoral Pain/Tenderness, Bony Enlargement and Joint Pain on Movement tests for knee osteoarthritis reached fair to excellent inter-rater reliability (k = 0.29 to 0.93). Based on low to moderate quality evidence, the Lateral Glide, Lateral Tilt, Lateral Pull and Quality of Movement tests for patellofemoral pain reached moderate to good inter-rater reliability (k = 0.49 to 0.73). Many physical tests appear to reach good inter-rater reliability, but this is based on low-quality and conflicting evidence. High-quality research is required to evaluate the reliability of knee physical examination tests. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Direct measurement of the field from a magnetic recording head using an InAs Hall sensor on a contact write/read tester

    International Nuclear Information System (INIS)

    Gokemeijer, N.J.; Clinton, T.W.; Crawford, T.M.; Johnson, Mark

    2005-01-01

    At 1 Tbit/in 2 areal density magnetic recording dimensions, reliable magnetic field metrology does not exist. One technique to map the spatial profile of the magnetic field of a write head is to use a contact read/write tester. A magnetic recording head is brought into contact with a Hall sensor, and is subsequently scanned with nm resolution. For a 300 nm track width longitudinal recording head, the magnetic field of the head was mapped. Measurements include the down track field gradient and cross-track field profile and the current-field transfer curve. These results suggest this technique offers a viable write field metrology

  11. Translation, reliability, and clinical utility of the Melbourne Assessment 2.

    Science.gov (United States)

    Gerber, Corinna N; Plebani, Anael; Labruyère, Rob

    2017-10-12

    The aims were to (i) provide a German translation of the Melbourne Assessment 2 (MA2), a quantitative test to measure unilateral upper limb function in children with neurological disabilities and (ii) to evaluate its reliability and aspects of clinical utility. After its translation into German and approval of the back translation by the original authors, the MA2 was performed and videotaped twice with 30 children with neuromotor disorders. For each participant, two raters scored the video of the first test for inter-rater reliability. To determine test-retest reliability, one rater additionally scored the video of the second test while the other rater repeated the scoring of the first video to evaluate intra-rater reliability. Time needed for rater training, test administration, and scoring was recorded. The four subscale scores showed excellent intra-, inter-rater, and test-retest reliability with intraclass correlation coefficients of 0.90-1.00 (95%-confidence intervals 0.78-1.00). Score items revealed substantial to almost perfect intra-rater reliability (weighted kappa k w  = 0.66-1.00) for the more affected side. Score item inter-rater and test-retest reliability of the same extremity were, with one exception, moderate to almost perfect (k w  = 0.42-0.97; k w  = 0.40-0.89). Furthermore, the MA2 was feasible and acceptable for patients and clinicians. The MA2 showed excellent subscale and moderate to almost perfect score item reliability. Implications for Rehabilitation There is a lack of high-quality studies about psychometric properties of upper limb measurement tools in the neuropediatric population. The Melbourne Assessment 2 is a promising tool for reliable measurement of unilateral upper limb movement quality in the neuropediatric population. The Melbourne Assessment 2 is acceptable and practicable to therapists and patients for routine use in clinical care.

  12. Development of a highly reliable CRT processor

    International Nuclear Information System (INIS)

    Shimizu, Tomoya; Saiki, Akira; Hirai, Kenji; Jota, Masayoshi; Fujii, Mikiya

    1996-01-01

    Although CRT processors have been employed by the main control board to reduce the operator's workload during monitoring, the control systems are still operated by hardware switches. For further advancement, direct controller operation through a display device is expected. A CRT processor providing direct controller operation must be as reliable as the hardware switches are. The authors are developing a new type of highly reliable CRT processor that enables direct controller operations. In this paper, we discuss the design principles behind a highly reliable CRT processor. The principles are defined by studies of software reliability and of the functional reliability of the monitoring and operation systems. The functional configuration of an advanced CRT processor is also addressed. (author)

  13. RELIABILITY OF THE DYNAMIC OCCUPATIONAL THERAPY COGNITIVE ASSESSMENT FOR CHILDREN (DOTCA-CH: THAI VERSION OF ORIENTATION, SPATIAL PERCEPTION, AND THINKING OPERATIONS SUBTESTS

    Directory of Open Access Journals (Sweden)

    Suchitporn Lersilp

    2014-06-01

    Full Text Available The Dynamic Occupational Therapy Cognitive Assessment for Children (DOTCA-Ch is a tool for finding out about cognitive problems in school-aged children. However, the DOTCA-Ch was developed in English for Western children. For this reason, it’s not appropriate for Thai children because of the differences of culture and language. The objectives of this study were aimed at translating the DOTCA-Ch in Orientation, Spatial Perception, and Thinking Operations subtests to a Thai version with a World Health Organization back-translation process, and to examine its internal consistency, inter-rater reliability and test-retest reliability. The participants consisted of 38 intellectually impaired and learning disabled individuals between the ages of 6–12. Results from this study revealed high internal consistency in the Orientation subtest (α=.83 Spatial Perception subtest (α=.82 and Thinking Operations subtest (α=.82, high inter-rater reliability in the Orientation subtest (ICC =.83, Spatial Perception subtest (ICC =.84 and Thinking Operations subtest (ICC =.74 and high test-retest reliability in the Orientation subtest (ICC =.84 Spatial Perception subtest (ICC =.86 and Thinking Operations subtest (ICC =.85. These results indicate that the Thai version of the DOTCA-Ch in Orientation, Spatial Perception, and Thinking Operations subtests  might be used as an appropriate assessment tool for Thai children, based on psychometric evidence including internal consistency, inter-rater reliability and test-retest reliability. However, additional study of other psychometric properties, including, predictive validity, concurrent reliability, and inter-rater reliability during the mediation process of this assessment tool needs to be carried out.

  14. Test strategies for industrial testers for converter controls equipment

    International Nuclear Information System (INIS)

    Oleniuk, P.; Kasampalis, V.; Cosmo, M. Di; Nisbet, D.; Todd, B.; Uznański, S.

    2017-01-01

    Power converters and their controls electronics are key elements for the operation of the CERN accelerator complex, having a direct impact on its availability. To prevent early-life failures and provide means to verify electronics, a set of industrial testers is used throughout the converters controls electronics' life cycle. The roles of the testers are to validate mass production during the manufacturing phase and to provide means to diagnose and repair failed modules that are brought back from operation. In the converter controls electronics section of the power converters group in the technology department of CERN (TE/EPC/CCE), two main test platforms have been adopted: a PXI platform for mixed analogue-digital functional tests and a JTAG Boundary-Scan platform for digital interconnection and functional tests. Depending on the functionality of the device under test, the appropriate test platforms are chosen. This paper is a follow-up to results presented at the TWEPP 2015 conference, adding the boundary scan test platform and the first results from exploitation of the test system. This paper reports on the test software, hardware design and test strategy applied for a number of devices that has resulted in maximizing test coverage and minimizing test design effort.

  15. Standardization, Validity and Reliability Study of Gülhane Aphasia Test-2 (GAT-2

    Directory of Open Access Journals (Sweden)

    İlknur Maviş

    2007-04-01

    Full Text Available OBJECTIVE: Gülhane Aphasia Test-2 (GAT-2 has been developed to show the presence of a language disorder ‘aphasia’ and to give the clinician implications for the accompanying speech disorders such as apraxia and dysarthria. OBJECTIVE: The aim of the study was to report standardization, validity and reliability study of GAT-2. METHODS: : 10 healthy individuals were tested initially for the pilot study. 134 healthy individual was included to the standardization study and 30 individuals with aphasia and 11 individuals with right brain injury was included to the validation study. The inter group GAT-2 score differentiations and the effects of age, years of education, sex variances were observed. GAT-2 cut-off scores were calculated by the scores of healthy individuals. GAT-2 test-retest reliability and inter-observer reliability was calculated. RESULTS: Healthy individuals’ GAT-2 scores were significantly different from the GAT-2 scores of aphasic patients, but not from right brain injured patients’. Healthy individuals’ GAT-2 scores were not affected from the sex, age variances but from years of education, so cut-off scores were calculated by this variance. GAT-2 scores of aphasic patients were not affected from age, sex and years of education. Test-retest and inter-observer reliability and internal consistency results showed that GAT-2 is a highly reliable aphasia screening test. CONCLUSION: GAT-2 was found to be a standardized, highly reliable and a valid aphasia test for Turkish stroke patients with aphasia

  16. Inter-Vehicle Communication System Utilizing Autonomous Distributed Transmit Power Control

    Science.gov (United States)

    Hamada, Yuji; Sawa, Yoshitsugu; Goto, Yukio; Kumazawa, Hiroyuki

    In ad-hoc network such as inter-vehicle communication (IVC) system, safety applications that vehicles broadcast the information such as car velocity, position and so on periodically are considered. In these applications, if there are many vehicles broadcast data in a communication area, congestion incurs a problem decreasing communication reliability. We propose autonomous distributed transmit power control method to keep high communication reliability. In this method, each vehicle controls its transmit power using feed back control. Furthermore, we design a communication protocol to realize the proposed method, and we evaluate the effectiveness of proposed method using computer simulation.

  17. Harmonization process and reliability assessment of anthropometric measurements in the elderly EXERNET multi-centre study.

    Directory of Open Access Journals (Sweden)

    Alba Gómez-Cabello

    Full Text Available BACKGROUND: The elderly EXERNET multi-centre study aims to collect normative anthropometric data for old functionally independent adults living in Spain. PURPOSE: To describe the standardization process and reliability of the anthropometric measurements carried out in the pilot study and during the final workshop, examining both intra- and inter-rater errors for measurements. MATERIALS AND METHODS: A total of 98 elderly from five different regions participated in the intra-rater error assessment, and 10 different seniors living in the city of Toledo (Spain participated in the inter-rater assessment. We examined both intra- and inter-rater errors for heights and circumferences. RESULTS: For height, intra-rater technical errors of measurement (TEMs were smaller than 0.25 cm. For circumferences and knee height, TEMs were smaller than 1 cm, except for waist circumference in the city of Cáceres. Reliability for heights and circumferences was greater than 98% in all cases. Inter-rater TEMs were 0.61 cm for height, 0.75 cm for knee-height and ranged between 2.70 and 3.09 cm for the circumferences measured. Inter-rater reliabilities for anthropometric measurements were always higher than 90%. CONCLUSION: The harmonization process, including the workshop and pilot study, guarantee the quality of the anthropometric measurements in the elderly EXERNET multi-centre study. High reliability and low TEM may be expected when assessing anthropometry in elderly population.

  18. Tester og testtilbakemeldinger som direkte bidragsytere til dypere læring blant studenter

    Directory of Open Access Journals (Sweden)

    Henrik Herrebrøden

    2014-11-01

    Full Text Available Denne artikkelen diskuterer forskning som tilsier at tester og testtilbakemeldinger kan bidra til dypere læring blant studenter. Testing har vist seg å forbedre langtidshukommelsen av innlært kunnskap sammenlignet med repetert lesing, noe som kalles for testeffekten. For at testeffekten skal optimaliseres, bør tester utformes med mål om å bidra til dyp prosessering av innlært kunnskap. Testtilbakemeldingers rolle i utdanning kan være å bidra til økt metakognitiv selvregulering blant studenter. For at selvregulering skal promoteres best mulig, bør testtilbakemeldinger inneholde utdypende informasjon. Samlet ser tester og testtilbakemeldinger ut til å være nyttige læringsverktøy og potensielle bidragsytere til dypere læring blant studenter.AbstractThis article discusses research supporting that tests and test feedback are learning tools that may promote deeper learning among students. Testing improves long-term retention of knowledge compared to repeated study, a phenomenon known as the testing effect. In order to promote the testing effect, tests should facilitate deep processing of knowledge among students. Test feedback has the potential to increase students’ metacognitive self-regulation. For this type of metacognition to be enhanced, feedback should contain elaborate information. Conclusively, tests and test feedback appear to be valuable learning tools and potential promoters of deeper learning.

  19. A national drug related problems database: evaluation of use in practice, reliability and reproducibility

    DEFF Research Database (Denmark)

    Kjeldsen, Lene Juel; Birkholm, Trine; Fischer, Hanne Lis

    2014-01-01

    Background A drug related problems database (DRP-database) was developed on request by clinical pharmacists. The information from the DRP-database has only been used locally e.g. to identify focus areas and to communicate identified DRPs to the hospital wards. Hence the quality of the data...... by clinical pharmacists with categorization performed by the project group. Reproducibility was explored by re-categorization of a sample of existing records in the DRP-database by two project group members individually. Main outcome measures Observed proportion of agreement and Fleiss' kappa as measures...... reliability study of 34 clinical pharmacists showed high inter-rater reliability with the project group (Fleiss' kappa = 0.79 with 95 % CI (0.70; 0.88)), and the reproducibility study also documented high inter-rater reliability of a sample of 379 records from the DRP-database re-categorized by two project...

  20. High-reliability health care: getting there from here.

    Science.gov (United States)

    Chassin, Mark R; Loeb, Jerod M

    2013-09-01

    Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer "project fatigue" because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals' readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Hospitals can make substantial progress toward high reliability by undertaking several specific organizational change initiatives. Further research

  1. Confiabilidade intra e interexaminador da análise por padrões de impressão de plantigrafias de pessoas diabéticas obtidas com o Harris Mat Inter- and intra-examiner reliability of footprint pattern analysis obtained from diabetics using the Harris Mat

    Directory of Open Access Journals (Sweden)

    Lígia L. Cisneros

    2010-06-01

    Full Text Available INTRODUÇÃO: A hiperpressão plantar é um fator de risco comprovado para a ulceração em portadores de diabetes mellitus. O "Harris and Beath Footprinting Mat" é um dos instrumentos usados nas avaliações para rastreamento do risco de ulceração nos pés desses pacientes. Não há relatos na literatura sobre estudos da confiabilidade da análise das impressões plantares usando o critério de padrões de impressão. OBJETIVO: O objetivo deste estudo foi avaliar a confiabilidade inter e intraexaminador da análise dos padrões de impressão plantar obtida com o "Harris and Beath Footprinting Mat". MÉTODOS: As impressões plantares de 41 sujeitos foram obtidas usando o plantígrafo. As imagens foram submetidas à análise de três examinadores independentes. Para verificar a confiabilidade intraexaminador, um dos examinadores repetiu a análise após uma semana. RESULTADOS: O coeficiente de Kappa ponderado foi excelente (Kp>0,80 para as análises inter e intraexaminador para a maioria dos pontos estudados em ambos os pés. CONCLUSÃO: O critério de análise por padrões de impressão plantar obtidas com o "Harris and Beath Footprinting Mat" apresentou boa confiabilidade e de alta a excelente concordância para as condições inter e intraexaminador. Esse método é confiável para análises que envolvam um ou mais examinadores.INTRODUCTION: High plantar pressure is a proven risk factor for ulceration among individuals with diabetes mellitus. The Harris and Beath footprinting mat is one of the tools used in screening for foot ulceration risk among these subjects. There are no reports in the literature on the reliability of footprint analysis using print pattern criteria. OBJECTIVE: The aim of this study was to evaluate the inter- and intra-examiner reliability of the analysis of footprint patterns obtained using the Harris and Beath footprinting mat. METHODS: Footprints were taken from 41 subjects using the footprinting mat. The images were

  2. Intrarater reliability of hand held dynamometry in measuring lower extremity isometric strength using a portable stabilization device.

    Science.gov (United States)

    Jackson, Steven M; Cheng, M Samuel; Smith, A Russell; Kolber, Morey J

    2017-02-01

    Hand held dynamometry (HHD) is a more objective way to quantify muscle force production (MP) compared to traditional manual muscle testing. HHD reliability can be negatively impacted by both the strength of the tester and the subject particularly in the lower extremities due to larger muscle groups. The primary aim of this investigation was to assess intrarater reliability of HHD with use of a portable stabilization device for lower extremity MP in an athletic population. Isometric lower extremity strength was measured for bilateral lower extremities including hip abductors, external rotators, adductors, knee extensors, and ankle plantar flexors was measured in a sample of healthy recreational runners (8 male, 7 females, = 30 limbs) training for a marathon. These measurements were assessed using an intrasession intrarater reliability design. Intraclass correlation coefficients (ICC) were calculated using 3,1 model based on the single rater design. The standard error of measurement (SEM) for each muscle group was also calculated. ICC were excellent ranging from ICC (3,1) = 0.93-0.98 with standard error of measurements ranging from 0.58 to 17.2 N. This study establishes the use of a HHD with a portable stabilization device as demonstrating good reliability within testers for measuring lower extremity muscle performance in an active healthy population. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Inter-Reader Reliability of Early FDG-PET/CT Response Assessment Using the Deauville Scale after 2 Cycles of Intensive Chemotherapy (OEPA) in Hodgkin's Lymphoma.

    LENUS (Irish Health Repository)

    Kluge, Regine

    2016-01-01

    The five point Deauville (D) scale is widely used to assess interim PET metabolic response to chemotherapy in Hodgkin lymphoma (HL) patients. An International Validation Study reported good concordance among reviewers in ABVD treated advanced stage HL patients for the binary discrimination between score D1,2,3 and score D4,5. Inter-reader reliability of the whole scale is not well characterised.

  4. Reliable and fast volumetry of the lumbar spinal cord using cord image analyser (Cordial).

    Science.gov (United States)

    Tsagkas, Charidimos; Altermatt, Anna; Bonati, Ulrike; Pezold, Simon; Reinhard, Julia; Amann, Michael; Cattin, Philippe; Wuerfel, Jens; Fischer, Dirk; Parmar, Katrin; Fischmann, Arne

    2018-04-30

    To validate the precision and accuracy of the semi-automated cord image analyser (Cordial) for lumbar spinal cord (SC) volumetry in 3D T1w MRI data of healthy controls (HC). 40 3D T1w images of 10 HC (w/m: 6/4; age range: 18-41 years) were acquired at one 3T-scanner in two MRI sessions (time interval 14.9±6.1 days). Each subject was scanned twice per session, allowing determination of test-retest reliability both in back-to-back (intra-session) and scan-rescan images (inter-session). Cordial was applied for lumbar cord segmentation twice per image by two raters, allowing for assessment of intra- and inter-rater reliability, and compared to a manual gold standard. While manually segmented volumes were larger (mean: 2028±245 mm 3 vs. Cordial: 1636±300 mm 3 , p<0.001), accuracy assessments between manually and semi-automatically segmented images showed a mean Dice-coefficient of 0.88±0.05. Calculation of within-subject coefficients of variation (COV) demonstrated high intra-session (1.22-1.86%), inter-session (1.26-1.84%), as well as intra-rater (1.73-1.83%) reproducibility. No significant difference was shown between intra- and inter-session reproducibility or between intra-rater reliabilities. Although inter-rater reproducibility (COV: 2.87%) was slightly lower compared to all other reproducibility measures, between rater consistency was very strong (intraclass correlation coefficient: 0.974). While under-estimating the lumbar SCV, Cordial still provides excellent inter- and intra-session reproducibility showing high potential for application in longitudinal trials. • Lumbar spinal cord segmentation using the semi-automated cord image analyser (Cordial) is feasible. • Lumbar spinal cord is 40-mm cord segment 60 mm above conus medullaris. • Cordial provides excellent inter- and intra-session reproducibility in lumbar spinal cord region. • Cordial shows high potential for application in longitudinal trials.

  5. Contribution to high voltage matrix switches reliability

    International Nuclear Information System (INIS)

    Lausenaz, Yvan

    2000-01-01

    Nowadays, power electronic equipment requirements are important, concerning performances, quality and reliability. On the other hand, costs have to be reduced in order to satisfy the market rules. To provide cheap, reliability and performances, many standard components with mass production are developed. But the construction of specific products must be considered following these two different points: in one band you can produce specific components, with delay, over-cost problems and eventuality quality and reliability problems, in the other and you can use standard components in a adapted topologies. The CEA of Pierrelatte has adopted this last technique of power electronic conception for the development of these high voltage pulsed power converters. The technique consists in using standard components and to associate them in series and in parallel. The matrix constitutes high voltage macro-switch where electrical parameters are distributed between the synchronized components. This study deals with the reliability of these structures. It brings up the high reliability aspect of MOSFETs matrix associations. Thanks to several homemade test facilities, we obtained lots of data concerning the components we use. The understanding of defects propagation mechanisms in matrix structures has allowed us to put forwards the necessity of robust drive system, adapted clamping voltage protection, and careful geometrical construction. All these reliability considerations in matrix associations have notably allowed the construction of a new matrix structure regrouping all solutions insuring reliability. Reliable and robust, this product has already reaches the industrial stage. (author) [fr

  6. Improving deposition tester to study adherent deposits in papermaking

    OpenAIRE

    Monte Lara, Concepción; Sánchez, Mónica; Blanco Suárez, Ángeles; Negro Álvarez, Carlos; Tijero Miquel, Julio

    2012-01-01

    Conventional methods used for the quantification of adherent material contained in a pulp suspension propose either filtration of the sample, which may lead to loss of sticky material in the filtrate, or dilution of the pulp, which may cause destabilization of the dissolved and colloidal material; thus, leading to unreliable results. In 1998, the Cellulose and Paper Group of University Complutense of Madrid developed a deposition tester which aimed to quantify the adherence of material (micro...

  7. NPS-SCAT (Solar Cell Array Tester), The Construction of NPS' First Prototype CubeSat

    National Research Council Canada - National Science Library

    Bein, Alexander L

    2008-01-01

    .... This Master's Thesis describes the NPS-SCAT (solar cell array tester) project, including the author's experience as program manager of the project, responsible for budget, schedule and technical deliverables...

  8. Strength and Pain Threshold Handheld Dynamometry Test Reliability in Patellofemoral Pain.

    Science.gov (United States)

    van der Heijden, R A; Vollebregt, T; Bierma-Zeinstra, S M A; van Middelkoop, M

    2015-12-01

    Patellofemoral pain syndrome (PFPS), characterized by peri- and retropatellar pain, is a common disorder in young, active people. The etiology is unclear; however, quadriceps strength seems to be a contributing factor, and sensitization might play a role. The study purpose is determining the inter-rater reliability of handheld dynamometry to test both quadriceps strength and pressure pain threshold (PPT), a measure for sensitization, in patients with PFPS. This cross-sectional case-control study comprises 3 quadriceps strength and one PPT measurements performed by 2 independent investigators in 22 PFPS patients and 16 matched controls. Inter-rater reliability was analyzed using intraclass correlation coefficients (ICC) and Bland-Altman plots. Inter-rater reliability of quadriceps strength testing was fair to good in PFPS patients (ICC=0.72) and controls (ICC=0.63). Bland-Altman plots showed an increased difference between assessors when average quadriceps strength values exceeded 250 N. Inter-rater reliability of PPT was excellent in patients (ICC=0.79) and fair to good in controls (ICC=0.52). Handheld dynamometry seems to be a reliable method to test both quadriceps strength and PPT in PFPS patients. Inter-rater reliability was higher in PFPS patients compared to control subjects. With regard to quadriceps testing, a higher variance between assessors occurs when quadriceps strength increases. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Optimization of nitridation conditions for high quality inter-polysilicon dielectric layers

    NARCIS (Netherlands)

    Klootwijk, J.H.; Bergveld, H.J.; van Kranenburg, H.; Woerlee, P.H.; Wallinga, Hans

    1996-01-01

    Nitridation of deposited high temperature oxides (HTO) was studied to form high quality inter-polysilicon dielectric layers for embedded non volatile memories. Good quality dielectric layers were obtained earlier by using an optimized deposition of polysilicon and by performing a post-dielectric

  10. MC-TESTER v. 1.23: A universal tool for comparisons of Monte Carlo predictions for particle decays in high energy physics

    Science.gov (United States)

    Davidson, N.; Golonka, P.; Przedziński, T.; Waş, Z.

    2011-03-01

    Theoretical predictions in high energy physics are routinely provided in the form of Monte Carlo generators. Comparisons of predictions from different programs and/or different initialization set-ups are often necessary. MC-TESTER can be used for such tests of decays of intermediate states (particles or resonances) in a semi-automated way. Since 2002 new functionalities were introduced into the package. In particular, it now works with the HepMC event record, the standard for C++ programs. The complete set-up for benchmarking the interfaces, such as interface between τ-lepton production and decay, including QED bremsstrahlung effects is shown. The example is chosen to illustrate the new options introduced into the program. From the technical perspective, our paper documents software updates and supplements previous documentation. As in the past, our test consists of two steps. Distinct Monte Carlo programs are run separately; events with decays of a chosen particle are searched, and information is stored by MC-TESTER. Then, at the analysis step, information from a pair of runs may be compared and represented in the form of tables and plots. Updates introduced in the program up to version 1.24.4 are also documented. In particular, new configuration scripts or script to combine results from multitude of runs into single information file to be used in analysis step are explained. Program summaryProgram title: MC-TESTER, version 1.23 and version 1.24.4 Catalog identifier: ADSM_v2_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADSM_v2_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 250 548 No. of bytes in distributed program, including test data, etc.: 4 290 610 Distribution format: tar.gz Programming language: C++, FORTRAN77 Tested and compiled with: gcc 3.4.6, 4

  11. Reliability and validity in measurement of true humeral retroversion by a three-dimensional cylinder fitting method.

    Science.gov (United States)

    Saka, Masayuki; Yamauchi, Hiroki; Hoshi, Kenji; Yoshioka, Toru; Hamada, Hidetoshi; Gamada, Kazuyoshi

    2015-05-01

    Humeral retroversion is defined as the orientation of the humeral head relative to the distal humerus. Because none of the previous methods used to measure humeral retroversion strictly follow this definition, values obtained by these techniques vary and may be biased by morphologic variations of the humerus. The purpose of this study was 2-fold: to validate a method to define the axis of the distal humerus with a virtual cylinder and to establish the reliability of 3-dimensional (3D) measurement of humeral retroversion by this cylinder fitting method. Humeral retroversion in 14 baseball players (28 humeri) was measured by the 3D cylinder fitting method. The root mean square error was calculated to compare values obtained by a single tester and by 2 different testers using the embedded coordinate system. To establish the reliability, intraclass correlation coefficient (ICC) and precision (standard error of measurement [SEM]) were calculated. The root mean square errors for the humeral coordinate system were reliability and precision of the 3D measurement of retroversion yielded an intratester ICC of 0.99 (SEM, 1.0°) and intertester ICC of 0.96 (SEM, 2.8°). The error in measurements obtained by a distal humerus cylinder fitting method was small enough not to affect retroversion measurement. The 3D measurement of retroversion by this method provides excellent intratester and intertester reliability. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  12. Development of a Portable Torque Wrench Tester

    Science.gov (United States)

    Wang, Y.; Zhang, Q.; Gou, C.; Su, D.

    2018-03-01

    A portable torque wrench tester (PTWT) with calibration range from 0.5 Nm to 60 Nm has been developed and evaluated for periodic or on-site calibration of setting type torque wrenches, indicating type torque wrenches and hand torque screwdrivers. The PTWT is easy to carry with weight about 10 kg, simple and efficient operation and energy saving with an automatic loading and calibrating system. The relative expanded uncertainty of torque realized by the PTWT was estimated to be 0.8%, with the coverage factor k=2. A comparison experiment has been done between the PTWT and a reference torque standard at our laboratory. The consistency between these two devices under the claimed uncertainties was verified.

  13. Development of high-reliable real-time communication network protocol for SMART

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ki Sang; Kim, Young Sik [Korea National University of Education, Chongwon (Korea); No, Hee Chon [Korea Advanced Institute of Science and Technology, Taejon (Korea)

    1999-04-01

    In this research, we first define protocol subsets for SMART(System-integrated Modular Advanced Reactor) communication network based on the requirement of SMART MMIS transmission delay and traffic requirements and OSI(Open System Interconnection) 7 layers' network protocol functions. Also, current industrial purpose LAN protocols are analyzed and the applicability of commercialized protocols are checked. For the suitability test, we have applied approximated SMART data traffic and maximum allowable transmission delay requirement. With the simulation results, we conclude that IEEE 802.5 and FDDI which is an ANSI standard, is the most suitable for SMART. We further analyzed the FDDI and token ring protocols for SMART and nuclear plant network environment including IEEE 802.4, IEEE 802.5, and ARCnet. The most suitable protocol for SMART is FDDI and FDDI MAC and RMT protocol specifications have been verified with LOTOS and the verification results show that FDDI MAC and RMT satisfy the reachability and liveness, but does not show deadlock and livelock. Therefore, we conclude that FDDI MAC and RMT is highly reliable protocol for SMART MMIS network. After that, we consider the stacking fault of IEEE 802.5 token ring protocol and propose a fault tolerant MAM(Modified Active Monitor) protocol. The simulation results show that the MAM protocol improves lower priority traffic service rate when stacking fault occurs. Therefore, proposed MAM protocol can be applied to SMART communication network for high reliability and hard real-time communication purpose in data acquisition and inter channel network. (author). 37 refs., 79 figs., 39 tabs.

  14. Interrater and Test-Retest Reliability and Minimal Detectable Change of the Balance Evaluation Systems Test (BESTest) and Subsystems With Community-Dwelling Older Adults.

    Science.gov (United States)

    Wang-Hsu, Elizabeth; Smith, Susan S

    2017-01-10

    Falls are a common cause of injuries and hospital admissions in older adults. Balance limitation is a potentially modifiable factor contributing to falls. The Balance Evaluation Systems Test (BESTest), a clinical balance measure, categorizes balance into 6 underlying subsystems. Each of the subsystems is scored individually and summed to obtain a total score. The reliability of the BESTest and its individual subsystems has been reported in patients with various neurological disorders and cancer survivors. However, the reliability and minimal detectable change (MDC) of the BESTest with community-dwelling older adults have not been reported. The purposes of our study were to (1) determine the interrater and test-retest reliability of the BESTest total and subsystem scores; and (2) estimate the MDC of the BESTest and its individual subsystem scores with community-dwelling older adults. We used a prospective cohort methodological design. Community-dwelling older adults (N = 70; aged 70-94 years; mean = 85.0 [5.5] years) were recruited from a senior independent living community. Trained testers (N = 3) administered the BESTest. All participants were tested with the BESTest by the same tester initially and then retested 7 to 14 days later. With 32 of the participants, a second tester concurrently scored the retest for interrater reliability. Testers were blinded to each other's scores. Intraclass correlation coefficients [ICC(2,1)] were used to determine the interrater and test-retest reliability. Test-retest reliability was also analyzed using method error and the associated coefficients of variation (CVME). MDC was calculated using standard error of measurement. Interrater reliability (N = 32) of the BESTest total score was ICC(2, 1) = 0.97 (95% confidence interval [CI], 0.94-0.99). The ICCs for the individual subsystem scores ranged from 0.85 to 0.94. Test-retest reliability (N = 70) of the BESTest total score was ICC(2,1) = 0.93 (95% CI, 0.89-0.96). ICCs for the

  15. Reliability of the Crowe und Hartofilakidis classifications used in the assessment of the adult dysplastic hip

    Energy Technology Data Exchange (ETDEWEB)

    Decking, Ralf; Brunner, Alexander; Puhl, Wolfhart [University of Ulm, Orthopaedic Department, RKU, Ulm (Germany); Decking, Jens [Johannes Gutenberg University School of Medicine, Department of Orthopaedic Surgery, Mainz (Germany); Guenther, Klaus-Peter [University of Ulm, Orthopaedic Department, RKU, Ulm (Germany); University-Hospital Carl Gustav Carus, Department of Orthopaedics, Dresden (Germany)

    2006-05-15

    To assess the inter-observer and intra-observer reliability of two commonly used radiographic classification systems in the evaluation of hip dysplasia in skeletally mature adults. Three observers with different levels of training independently classified 62 dysplastic hips on 51 standard anteriorposterior pelvis radiographs according to the criteria defined by Crowe and by Hartofilakidis. To assess intra-observer reliability, the same radiographs were reviewed 3 months later by the same observers. At the time of the radiographic examination, the mean age of the 51 patients had been 54 years (range 18-82 years). A high correlation concerning the inter- and intra-observer reliability of both systems was demonstrated. Inter-observer reliability displayed a weighted kappa coefficient of 0.82 for the Crowe and 0.75 for the Hartofilakidis classification. Intra-observer reliability showed a kappa coefficient of 0.86 and 0.79, respectively. Both classification systems can be recommended to compare collectives of adult patients with congenital dysplasia of the hip. However, for future clinical practice, it would be advisable to agree on one universally accepted system as a standard in the literature. (orig.)

  16. Reliability of the Crowe und Hartofilakidis classifications used in the assessment of the adult dysplastic hip

    International Nuclear Information System (INIS)

    Decking, Ralf; Brunner, Alexander; Puhl, Wolfhart; Decking, Jens; Guenther, Klaus-Peter

    2006-01-01

    To assess the inter-observer and intra-observer reliability of two commonly used radiographic classification systems in the evaluation of hip dysplasia in skeletally mature adults. Three observers with different levels of training independently classified 62 dysplastic hips on 51 standard anteriorposterior pelvis radiographs according to the criteria defined by Crowe and by Hartofilakidis. To assess intra-observer reliability, the same radiographs were reviewed 3 months later by the same observers. At the time of the radiographic examination, the mean age of the 51 patients had been 54 years (range 18-82 years). A high correlation concerning the inter- and intra-observer reliability of both systems was demonstrated. Inter-observer reliability displayed a weighted kappa coefficient of 0.82 for the Crowe and 0.75 for the Hartofilakidis classification. Intra-observer reliability showed a kappa coefficient of 0.86 and 0.79, respectively. Both classification systems can be recommended to compare collectives of adult patients with congenital dysplasia of the hip. However, for future clinical practice, it would be advisable to agree on one universally accepted system as a standard in the literature. (orig.)

  17. Surgeon Reliability for the Assessment of Lumbar Spinal Stenosis on MRI: The Impact of Surgeon Experience.

    Science.gov (United States)

    Marawar, Satyajit V; Madom, Ian A; Palumbo, Mark; Tallarico, Richard A; Ordway, Nathaniel R; Metkar, Umesh; Wang, Dongliang; Green, Adam; Lavelle, William F

    2017-01-01

    Treating surgeon's visual assessment of axial MRI images to ascertain the degree of stenosis has a critical impact on surgical decision-making. The purpose of this study was to prospectively analyze the impact of surgeon experience on inter-observer and intra-observer reliability of assessing severity of spinal stenosis on MRIs by spine surgeons directly involved in surgical decision-making. Seven fellowship trained spine surgeons reviewed MRI studies of 30 symptomatic patients with lumbar stenosis and graded the stenosis in the central canal, the lateral recess and the foramen at T12-L1 to L5-S1 as none, mild, moderate or severe. No specific instructions were provided to what constituted mild, moderate, or severe stenosis. Two surgeons were "senior" (>fifteen years of practice experience); two were "intermediate" (>four years of practice experience), and three "junior" (< one year of practice experience). The concordance correlation coefficient (CCC) was calculated to assess inter-observer reliability. Seven MRI studies were duplicated and randomly re-read to evaluate inter-observer reliability. Surgeon experience was found to be a strong predictor of inter-observer reliability. Senior inter-observer reliability was significantly higher assessing central(p<0.001), foraminal p=0.005 and lateral p=0.001 than "junior" group.Senior group also showed significantly higher inter-observer reliability that intermediate group assessing foraminal stenosis (p=0.036). In intra-observer reliability the results were contrary to that found in inter-observer reliability. Inter-observer reliability of assessing stenosis on MRIs increases with surgeon experience. Lower intra-observer reliability values among the senior group, although not clearly explained, may be due to the small number of MRIs evaluated and quality of MRI images.Level of evidence: Level 3.

  18. Inter-Rater Reliability and Agreement of the 6-Minute Walk Test in Women With Hip Fracture

    DEFF Research Database (Denmark)

    Larsen, Camilla Marie; Overgaard, Jan; Tange Kristensen, Morten

    MWT in individuals with hip fractures. Methods: Two senior physiotherapy students independently examined (randomized order) a convenient sample of 20 participants; their assessments were separated by two days, and testing followed instructions from the American Thoracic Society(1). Hip pain...... was assessed with the Verbal Ranking Scale. Results: Participants (all women) with a mean (SD) age of 78.1 ± 5.9 years performed the test within a mean of 31.5 ± 5.8 days post-surgery; 10 had a cervical and 10 a trochanteric fracture. Excellent inter-rater reliability; ICC2.1 =0.92 (95% CI, 0.81 - 0...... = -0.196, P = 0.41). On the contrary, participants walked a mean of 21.7 ± 22.6 meters longer, at the second trial (P = 0.002). Participants with moderate hip fracture- related pain walked a shorter distance than those with no or light pain during the first test (P = 0.04), while this was not the case...

  19. Reliability of Ultrasound Diameter Measurements in Patients with a Small Asymptomatic Popliteal Artery Aneurysm: An Intra- and Inter-observer Agreement Study.

    Science.gov (United States)

    Zwiers, I; Hoogland, C M T; Mackaay, A J C

    2016-03-01

    In this study the intra- and inter-observer variability of ultrasound measurements of the diameter of the popliteal artery were tested in a group of patients under surveillance for a small (diameter 10-20 mm), asymptomatic popliteal artery aneurysm (PAA). From a group of patients under ultrasound surveillance for bilateral, asymptomatic PAAs, 13 consecutive patients agreed to participate in the study and provided informed consent. The maximum diameter of the popliteal arteries was assessed by a vascular technologist. The same assessment was repeated by a second vascular technologist, unaware of the results of the first measurement. After a week, this protocol was repeated. The intra- and inter-observer reliability of this measurement was calculated using intra-class correlation coefficients (ICCs) and Bland and Altman plots. Of the 10 patients with bilateral and three patients with unilateral PAA, 12 completed the 2 week protocol. A total of 86 measurements were analyzed. The mean diameter of the popliteal arteries was 13.5 ± 3.4 mm. The ICC for the intra-observer reliability of observer 1 was 0.96 (95% CI 0.92-0.99), p .47. The absolute magnitude of the systematic error of both observers was less than 0.135 mm (median 0.00). Ultrasound measurement of the maximum diameter of the popliteal artery is reproducible; hence, it is suitable for making a clinical treatment decision. Its use for surveillance of small, asymptomatic PAAs is justified. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  20. The Korean version of relative and absolute reliability of gait and balance assessment tools for patients with dementia in day care center and nursing home.

    Science.gov (United States)

    Lee, Han Suk; Park, Sun Wook; Chung, Hyung Kuk

    2017-11-01

    [Purpose] This study was aimed to determine the relative and absolute reliability of Korean version tools of the Berg Balance Scale (BBS), the Timed Up and Go (TUG), the Four-Meter Walking Test (4MWT) and the Groningen Meander Walking Test (GMWT) in patients with dementia. [Subjects and Methods] A total of 53 patients with dementia were tested on TUG, BBS, 4MWT and GMWT with a prospective cohort methodological design. Intra-class Correlation Coefficients (ICCs) to assess relative reliability and the standard error of measurement (SEM), minimal detectable change (MDC 95 ) and its percentage (MDC % ) to analyze the absolute reliability were calculated. [Results] Inter-rater reliability (ICC (2,3) ) of TUG, BBS and GMWT was 0.99 and that of 4MWT was 0.82. Inter-rater reliability was high for TUG, BBS and GMWT, with low SEM, MDC 95 , and MDC % . Inter-rater reliability was low for 4MWT, with high SEM, MDC 95 , and MDC % . Test-retest (ICC (2,3) ) of TUG, BBS and GMWT was 0.96-0.99 and Test-retest (ICC (2,3) ) of 4MWT was 0.85. The test-retest was high for TUG, BBS and GMWT, with low SEM, MDC 95 , and MDC % , but it was low for 4MWT, with high SEM, MDC 95 , and MDC % . [Conclusion] The relative reliability was high for all the assessment tools. The absolute reliability has a reasonable level of stability except the 4MWT.

  1. Reliability of histologic assessment in patients with eosinophilic oesophagitis.

    Science.gov (United States)

    Warners, M J; Ambarus, C A; Bredenoord, A J; Verheij, J; Lauwers, G Y; Walsh, J C; Katzka, D A; Nelson, S; van Viegen, T; Furuta, G T; Gupta, S K; Stitt, L; Zou, G; Parker, C E; Shackelton, L M; D Haens, G R; Sandborn, W J; Dellon, E S; Feagan, B G; Collins, M H; Jairath, V; Pai, R K

    2018-04-01

    The validity of the eosinophilic oesophagitis (EoE) histologic scoring system (EoEHSS) has been demonstrated, but only preliminary reliability data exist. Formally assess the reliability of the EoEHSS and additional histologic features. Four expert gastrointestinal pathologists independently reviewed slides from adult patients with EoE (N = 45) twice, in random order, using standardised training materials and scoring conventions for the EoEHSS and additional histologic features agreed upon during a modified Delphi process. Intra- and inter-rater reliability for scoring the EoEHSS, a visual analogue scale (VAS) of overall histopathologic disease severity, and additional histologic features were assessed using intra-class correlation coefficients (ICCs). Almost perfect intra-rater reliability was observed for the composite EoEHSS scores and the VAS. Inter-rater reliability was also almost perfect for the composite EoEHSS scores and substantial for the VAS. Of the EoEHSS items, eosinophilic inflammation was associated with the highest ICC estimates and consistent with almost perfect intra- and inter-rater reliability. With the exception of dyskeratotic epithelial cells and surface epithelial alteration, ICC estimates for the remaining EoEHSS items were above the benchmarks for substantial intra-rater, and moderate inter-rater reliability. Estimation of peak eosinophil count and number of lamina propria eosinophils were associated with the highest ICC estimates among the exploratory items. The composite EoEHSS and most component items are associated with substantial reliability when assessed by central pathologists. Future studies should assess responsiveness of the score to change after a therapeutic intervention to facilitate its use in clinical trials. © 2018 John Wiley & Sons Ltd.

  2. Reliability and Failure in NASA Missions: Blunders, Normal Accidents, High Reliability, Bad Luck

    Science.gov (United States)

    Jones, Harry W.

    2015-01-01

    NASA emphasizes crew safety and system reliability but several unfortunate failures have occurred. The Apollo 1 fire was mistakenly unanticipated. After that tragedy, the Apollo program gave much more attention to safety. The Challenger accident revealed that NASA had neglected safety and that management underestimated the high risk of shuttle. Probabilistic Risk Assessment was adopted to provide more accurate failure probabilities for shuttle and other missions. NASA's "faster, better, cheaper" initiative and government procurement reform led to deliberately dismantling traditional reliability engineering. The Columbia tragedy and Mars mission failures followed. Failures can be attributed to blunders, normal accidents, or bad luck. Achieving high reliability is difficult but possible.

  3. The development of a reliable amateur boxing performance analysis template.

    Science.gov (United States)

    Thomson, Edward; Lamb, Kevin; Nicholas, Ceri

    2013-01-01

    The aim of this study was to devise a valid performance analysis system for the assessment of the movement characteristics associated with competitive amateur boxing and assess its reliability using analysts of varying experience of the sport and performance analysis. Key performance indicators to characterise the demands of an amateur contest (offensive, defensive and feinting) were developed and notated using a computerised notational analysis system. Data were subjected to intra- and inter-observer reliability assessment using median sign tests and calculating the proportion of agreement within predetermined limits of error. For all performance indicators, intra-observer reliability revealed non-significant differences between observations (P > 0.05) and high agreement was established (80-100%) regardless of whether exact or the reference value of ±1 was applied. Inter-observer reliability was less impressive for both analysts (amateur boxer and experienced analyst), with the proportion of agreement ranging from 33-100%. Nonetheless, there was no systematic bias between observations for any indicator (P > 0.05), and the proportion of agreement within the reference range (±1) was 100%. A reliable performance analysis template has been developed for the assessment of amateur boxing performance and is available for use by researchers, coaches and athletes to classify and quantify the movement characteristics of amateur boxing.

  4. Publishing nutrition research: validity, reliability, and diagnostic test assessment in nutrition-related research.

    Science.gov (United States)

    Gleason, Philip M; Harris, Jeffrey; Sheean, Patricia M; Boushey, Carol J; Bruemmer, Barbara

    2010-03-01

    This is the sixth in a series of monographs on research design and analysis. The purpose of this article is to describe and discuss several concepts related to the measurement of nutrition-related characteristics and outcomes, including validity, reliability, and diagnostic tests. The article reviews the methodologic issues related to capturing the various aspects of a given nutrition measure's reliability, including test-retest, inter-item, and interobserver or inter-rater reliability. Similarly, it covers content validity, indicators of absolute vs relative validity, and internal vs external validity. With respect to diagnostic assessment, the article summarizes the concepts of sensitivity and specificity. The hope is that dietetics practitioners will be able to both use high-quality measures of nutrition concepts in their research and recognize these measures in research completed by others. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  5. Reliability of ultrasound grading traditional score and new global OMERACT-EULAR score system (GLOESS): results from an inter- and intra-reading exercise by rheumatologists.

    Science.gov (United States)

    Ventura-Ríos, Lucio; Hernández-Díaz, Cristina; Ferrusquia-Toríz, Diana; Cruz-Arenas, Esteban; Rodríguez-Henríquez, Pedro; Alvarez Del Castillo, Ana Laura; Campaña-Parra, Alfredo; Canul, Efrén; Guerrero Yeo, Gerardo; Mendoza-Ruiz, Juan Jorge; Pérez Cristóbal, Mario; Sicsik, Sandra; Silva Luna, Karina

    2017-12-01

    This study aims to test the reliability of ultrasound to graduate synovitis in static and video images, evaluating separately grayscale and power Doppler (PD), and combined. Thirteen trained rheumatologist ultrasonographers participated in two separate rounds reading 42 images, 15 static and 27 videos, of the 7-joint count [wrist, 2nd and 3rd metacarpophalangeal (MCP), 2nd and 3rd interphalangeal (IPP), 2nd and 5th metatarsophalangeal (MTP) joints]. The images were from six patients with rheumatoid arthritis, performed by one ultrasonographer. Synovitis definition was according to OMERACT. Scoring system in grayscale, PD separately, and combined (GLOESS-Global OMERACT-EULAR Score System) were reviewed before exercise. Reliability intra- and inter-reading was calculated with Cohen's kappa weighted, according to Landis and Koch. Kappa values for inter-reading were good to excellent. The minor kappa was for GLOESS in static images, and the highest was for the same scoring in videos (k 0.59 and 0.85, respectively). Excellent values were obtained for static PD in 5th MTP joint and for PD video in 2nd MTP joint. Results for GLOESS in general were good to moderate. Poor agreement was observed in 3rd MCP and 3rd IPP in all kinds of images. Intra-reading agreement were greater in grayscale and GLOESS in static images than in videos (k 0.86 vs. 0.77 and k 0.86 vs. 0.71, respectively), but PD was greater in videos than in static images (k 1.0 vs. 0.79). The reliability of the synovitis scoring through static images and videos is in general good to moderate when using grayscale and PD separately or combined.

  6. Influence of wearing latex gloves on electric pulp tester readings in children.

    Science.gov (United States)

    Holan, G

    1993-12-01

    Electric pulp testers operated by completing an electric circuit. Latex examination gloves have been claimed to interrupt this circuit and lead to false-negative results. This study was conducted to evaluate the influence of wearing latex gloves on electric pulp tester (EPT) readings. The pulps of 80 maxillary permanent incisors of 22 children 10-13 1/2 years old were tested using the Pelton & Crane 'Vitapulp' instrument. Each tooth was tested twice: with gloves and with bare hands. Teeth failing to respond to the EPT without gloves were excluded from the study. All EPT readings ranged between 1 and 9.5. Five teeth gave the same responses with gloved and ungloved hands. Only five teeth did not respond when gloves were worn, and all of these gave readings near the top of the EPT scale when tested without gloves. The other 70 teeth presented significantly higher readings with gloves than without gloves. It is concluded that removal of examination gloves during the operation of the EPT is necessary only if no response is obtained.

  7. Student Precision and Reliability of the Team Sport Assessment in ...

    African Journals Online (AJOL)

    TSAP) and formative assessment of invasion sport. The specific objectives were to determine the degree of agreement among expert observers, inter-observer reliability (internal consistency), and intra observer reliability (temporal reliability).

  8. Inter-Rater Reliability of Historical Data Collected by Non-Medical Research Assistants and Physicians in Patients with Acute Abdominal Pain

    Directory of Open Access Journals (Sweden)

    Mills, Angela M

    2009-02-01

    Full Text Available OBJECTIVES: In many academic emergency departments (ED, physicians are asked to record clinical data for research that may be time consuming and distracting from patient care. We hypothesized that non-medical research assistants (RAs could obtain historical information from patients with acute abdominal pain as accurately as physicians.METHODS: Prospective comparative study conducted in an academic ED of 29 RAs to 32 resident physicians (RPs to assess inter-rater reliability in obtaining historical information in abdominal pain patients. Historical features were independently recorded on standardized data forms by a RA and RP blinded to each others' answers. Discrepancies were resolved by a third person (RA who asked the patient to state the correct answer on a third questionnaire, constituting the "criterion standard." Inter-rater reliability was assessed using kappa statistics (kappa and percent crude agreement (CrA.RESULTS: Sixty-five patients were enrolled (mean age 43. Of 43 historical variables assessed, the median agreement was moderate (kappa 0.59 [Interquartile range 0.37-0.69]; CrA 85.9% and varied across data categories: initial pain location (kappa 0.61 [0.59-0.73]; CrA 87.7%, current pain location (kappa 0.60 [0.47-0.67]; CrA 82.8%, past medical history (kappa 0.60 [0.48-0.74]; CrA 93.8%, associated symptoms (kappa 0.38 [0.37-0.74]; CrA 87.7%, and aggravating/alleviating factors (kappa 0.09 [-0.01-0.21]; CrA 61.5%. When there was disagreement between the RP and the RA, the RA more often agreed with the criterion standard (64% [55-71%] than the RP (36% [29-45%].CONCLUSION: Non-medical research assistants who focus on clinical research are often more accurate than physicians, who may be distracted by patient care responsibilities, at obtaining historical information from ED patients with abdominal pain.

  9. The reliability of three psoriasis assessment tools: Psoriasis area and severity index, body surface area and physician global assessment.

    Science.gov (United States)

    Bożek, Agnieszka; Reich, Adam

    2017-08-01

    A wide variety of psoriasis assessment tools have been proposed to evaluate the severity of psoriasis in clinical trials and daily practice. The most frequently used clinical instrument is the psoriasis area and severity index (PASI); however, none of the currently published severity scores used for psoriasis meets all the validation criteria required for an ideal score. The aim of this study was to compare and assess the reliability of 3 commonly used assessment instruments for psoriasis severity: the psoriasis area and severity index (PASI), body surface area (BSA) and physician global assessment (PGA). On the scoring day, 10 trained dermatologists evaluated 9 adult patients with plaque-type psoriasis using the PASI, BSA and PGA. All the subjects were assessed twice by each physician. Correlations between the assessments were analyzed using the Pearson correlation coefficient. Intra-class correlation coefficient (ICC) was calculated to analyze intra-rater reliability, and the coefficient of variation (CV) was used to assess inter-rater variability. Significant correlations were observed among the 3 scales in both assessments. In all 3 scales the ICCs were > 0.75, indicating high intra-rater reliability. The highest ICC was for the BSA (0.96) and the lowest one for the PGA (0.87). The CV for the PGA and PASI were 29.3 and 36.9, respectively, indicating moderate inter-rater variability. The CV for the BSA was 57.1, indicating high inter-rater variability. Comparing the PASI, PGA and BSA, it was shown that the PGA had the highest inter-rater reliability, whereas the BSA had the highest intra-rater reliability. The PASI showed intermediate values in terms of interand intra-rater reliability. None of the 3 assessment instruments showed a significant advantage over the other. A reliable assessment of psoriasis severity requires the use of several independent evaluations simultaneously.

  10. Diagnostic reliability of MMPI-2 computer-based test interpretations.

    Science.gov (United States)

    Pant, Hina; McCabe, Brian J; Deskovitz, Mark A; Weed, Nathan C; Williams, John E

    2014-09-01

    Reflecting the common use of the MMPI-2 to provide diagnostic considerations, computer-based test interpretations (CBTIs) also typically offer diagnostic suggestions. However, these diagnostic suggestions can sometimes be shown to vary widely across different CBTI programs even for identical MMPI-2 profiles. The present study evaluated the diagnostic reliability of 6 commercially available CBTIs using a 20-item Q-sort task developed for this study. Four raters each sorted diagnostic classifications based on these 6 CBTI reports for 20 MMPI-2 profiles. Two questions were addressed. First, do users of CBTIs understand the diagnostic information contained within the reports similarly? Overall, diagnostic sorts of the CBTIs showed moderate inter-interpreter diagnostic reliability (mean r = .56), with sorts for the 1/2/3 profile showing the highest inter-interpreter diagnostic reliability (mean r = .67). Second, do different CBTIs programs vary with respect to diagnostic suggestions? It was found that diagnostic sorts of the CBTIs had a mean inter-CBTI diagnostic reliability of r = .56, indicating moderate but not strong agreement across CBTIs in terms of diagnostic suggestions. The strongest inter-CBTI diagnostic agreement was found for sorts of the 1/2/3 profile CBTIs (mean r = .71). Limitations and future directions are discussed. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  11. A measuring system for mechanical characterization of thin films based on a compact in situ micro-tensile tester and SEM moiré method

    International Nuclear Information System (INIS)

    Li, Yanjie; Tang, Minjin; Xie, Huimin; Zhu, Ronghua; Luo, Qiang; Gu, Changzhi

    2013-01-01

    A measuring system for mechanical characterization of thin films based on a compact in situ micro-tensile tester and scanning electron microscope (SEM) moiré method is proposed. The load is exerted by the tensile tester and the full field strain is measured by SEM moiré method. The configuration of the tensile tester and the principle of SEM moiré method are introduced. In the tensile tester, a lever structure is designed to amplify the displacement imposed by lead–zirconate–titanate (PZT) actuator. The SEM moiré method is applied to measure the strain of the thin film, including both the average strain in the gage section and the local strain distribution at a specific region. As an application, the measuring system is applied to characterize the mechanical property of the free-standing aluminum thin film. The experimental results demonstrate the feasibility of the system and its good application potential for mechanical behavior analysis of film-like materials. (paper)

  12. Achieving High Reliability with People, Processes, and Technology.

    Science.gov (United States)

    Saunders, Candice L; Brennan, John A

    2017-01-01

    High reliability as a corporate value in healthcare can be achieved by meeting the "Quadruple Aim" of improving population health, reducing per capita costs, enhancing the patient experience, and improving provider wellness. This drive starts with the board of trustees, CEO, and other senior leaders who ingrain high reliability throughout the organization. At WellStar Health System, the board developed an ambitious goal to become a top-decile health system in safety and quality metrics. To achieve this goal, WellStar has embarked on a journey toward high reliability and has committed to Lean management practices consistent with the Institute for Healthcare Improvement's definition of a high-reliability organization (HRO): one that is committed to the prevention of failure, early identification and mitigation of failure, and redesign of processes based on identifiable failures. In the end, a successful HRO can provide safe, effective, patient- and family-centered, timely, efficient, and equitable care through a convergence of people, processes, and technology.

  13. Peer-review for selection of oral presentations for conferences: Are we reliable?

    Science.gov (United States)

    Deveugele, Myriam; Silverman, Jonathan

    2017-11-01

    Although peer-review for journal submission, grant-applications and conference submissions has been called 'a counter- stone of science', and even 'the gold standard for evaluating scientific merit', publications on this topic remain scares. Research that has investigated peer-review reveals several issues and criticisms concerning bias, poor quality review, unreliability and inefficiency. The most important weakness of the peer review process is the inconsistency between reviewers leading to inadequate inter-rater reliability. To report the reliability of ratings for a large international conference and to suggest possible solutions to overcome the problem. In 2016 during the International Conference on Communication in Healthcare, organized by EACH: International Association for Communication in Healthcare, a calibration exercise was proposed and feedback was reported back to the participants of the exercise. Most abstracts, as well as most peer-reviewers, receive and give scores around the median. Contrary to the general assumption that there are high and low scorers, in this group only 3 peer-reviewers could be identified with a high mean, while 7 has a low mean score. Only 2 reviewers gave only high ratings (4 and 5). Of the eight abstracts included in this exercise, only one abstract received a high mean score and one a low mean score. Nevertheless, both these abstracts received both low and high scores; all other abstracts received all possible scores. Peer-review of submissions for conferences are, in accordance with the literature, unreliable. New and creative methods will be needed to give the participants of a conference what they really deserve: a more reliable selection of the best abstracts. More raters per abstract improves the inter-rater reliability; training of reviewers could be helpful; providing feedback to reviewers can lead to less inter-rater disagreement; fostering negative peer-review (rejecting the inappropriate submissions) rather than a

  14. INTRA-RATER RELIABILITY OF THE MULTIPLE SINGLE-LEG HOP-STABILIZATION TEST AND RELATIONSHIPS WITH AGE, LEG DOMINANCE AND TRAINING.

    Science.gov (United States)

    Sawle, Leanne; Freeman, Jennifer; Marsden, Jonathan

    2017-04-01

    Balance is a complex construct, affected by multiple components such as strength and co-ordination. However, whilst assessing an athlete's dynamic balance is an important part of clinical examination, there is no gold standard measure. The multiple single-leg hop-stabilization test is a functional test which may offer a method of evaluating the dynamic attributes of balance, but it needs to show adequate intra-tester reliability. The purpose of this study was to assess the intra-rater reliability of a dynamic balance test, the multiple single-leg hop-stabilization test on the dominant and non-dominant legs. Intra-rater reliability study. Fifteen active participants were tested twice with a 10-minute break between tests. The outcome measure was the multiple single-leg hop-stabilization test score, based on a clinically assessed numerical scoring system. Results were analysed using an Intraclass Correlations Coefficient (ICC 2,1 ) and Bland-Altman plots. Regression analyses explored relationships between test scores, leg dominance, age and training (an alpha level of p = 0.05 was selected). ICCs for intra-rater reliability were 0.85 for the dominant and non-dominant legs (confidence intervals = 0.62-0.95 and 0.61-0.95 respectively). Bland-Altman plots showed scores within two standard deviations. A significant correlation was observed between the dominant and non-dominant leg on balance scores (R 2 =0.49, ptest demonstrated strong intra-tester reliability with active participants. Younger participants who trained more, have better balance scores. This test may be a useful measure for evaluating the dynamic attributes of balance. 3.

  15. Validity and reliability of using photography for measuring knee range of motion: a methodological study

    Directory of Open Access Journals (Sweden)

    Adie Sam

    2011-04-01

    Full Text Available Abstract Background The clinimetric properties of knee goniometry are essential to appreciate in light of its extensive use in the orthopaedic and rehabilitative communities. Intra-observer reliability is thought to be satisfactory, but the validity and inter-rater reliability of knee goniometry often demonstrate unacceptable levels of variation. This study tests the validity and reliability of measuring knee range of motion using goniometry and photographic records. Methods Design: Methodology study assessing the validity and reliability of one method ('Marker Method' which uses a skin marker over the greater trochanter and another method ('Line of Femur Method' which requires estimation of the line of femur. Setting: Radiology and orthopaedic departments of two teaching hospitals. Participants: 31 volunteers (13 arthritic and 18 healthy subjects. Knee range of motion was measured radiographically and photographically using a goniometer. Three assessors were assessed for reliability and validity. Main outcomes: Agreement between methods and within raters was assessed using concordance correlation coefficient (CCCs. Agreement between raters was assessed using intra-class correlation coefficients (ICCs. 95% limits of agreement for the mean difference for all paired comparisons were computed. Results Validity (referenced to radiographs: Each method for all 3 raters yielded very high CCCs for flexion (0.975 to 0.988, and moderate to substantial CCCs for extension angles (0.478 to 0.678. The mean differences and 95% limits of agreement were narrower for flexion than they were for extension. Intra-rater reliability: For flexion and extension, very high CCCs were attained for all 3 raters for both methods with slightly greater CCCs seen for flexion (CCCs varied from 0.981 to 0.998. Inter-rater reliability: For both methods, very high ICCs (min to max: 0.891 to 0.995 were obtained for flexion and extension. Slightly higher coefficients were obtained

  16. Internal Consistency of Reliability Assessment of the Persian version of the ‘Home Falls and Accident Screening Tool’

    Directory of Open Access Journals (Sweden)

    Afsoon Hassani Mehraban

    2013-10-01

    Full Text Available Objectives: Falling is a common problem among the elderly. Falling indoors and outdoors is highly prevalent among the Iranian elderly. Therefore, identification of the contributing factors at home and their modification can reduce falls and subsequent injuries inthe elderly. The goal of this study was to identify the elderly at risk of fall, using the ‘Home Falls and Accident Screening Tool’ (HOME FAST, and to determine the reliability of this tool. Methods: Sixty old people were selected from five geographical regions of Tehran through the Local Town Councils. Participants were aged 60 to 65 years, and HOME FAST was used to assess inter rater and test- retest reliability. Results: Test-retest reliability in the study showed that agreement between the items of the Persian version of HOME FAST was over 0.8, which is a very good reliability. The agreement between the domains was 0.65-1.00, indicative of moderate to high reliability. Moreover, the Inter rater reliability of the items was over 0.8, which is also very good. The correlation of each item between the domains was 0.01-1.00, which shows poor to high reliability. Discussion: This study showed that the reliability of the Persian version of HOME FAST is high. This tool can therefore be used as an appropriate screening tool by professionals to take necessary preventive measures for the Iranian elderly population.

  17. Reliability and validity of the Wolfram Unified Rating Scale (WURS

    Directory of Open Access Journals (Sweden)

    Nguyen Chau

    2012-11-01

    Full Text Available Abstract Background Wolfram syndrome (WFS is a rare, neurodegenerative disease that typically presents with childhood onset insulin dependent diabetes mellitus, followed by optic atrophy, diabetes insipidus, deafness, and neurological and psychiatric dysfunction. There is no cure for the disease, but recent advances in research have improved understanding of the disease course. Measuring disease severity and progression with reliable and validated tools is a prerequisite for clinical trials of any new intervention for neurodegenerative conditions. To this end, we developed the Wolfram Unified Rating Scale (WURS to measure the severity and individual variability of WFS symptoms. The aim of this study is to develop and test the reliability and validity of the Wolfram Unified Rating Scale (WURS. Methods A rating scale of disease severity in WFS was developed by modifying a standardized assessment for another neurodegenerative condition (Batten disease. WFS experts scored the representativeness of WURS items for the disease. The WURS was administered to 13 individuals with WFS (6-25 years of age. Motor, balance, mood and quality of life were also evaluated with standard instruments. Inter-rater reliability, internal consistency reliability, concurrent, predictive and content validity of the WURS were calculated. Results The WURS had high inter-rater reliability (ICCs>.93, moderate to high internal consistency reliability (Cronbach’s α = 0.78-0.91 and demonstrated good concurrent and predictive validity. There were significant correlations between the WURS Physical Assessment and motor and balance tests (rs>.67, ps>.76, ps=-.86, p=.001. The WURS demonstrated acceptable content validity (Scale-Content Validity Index=0.83. Conclusions These preliminary findings demonstrate that the WURS has acceptable reliability and validity and captures individual differences in disease severity in children and young adults with WFS.

  18. Development of new design mechanical seal tester for Primary Loop Recirculation Pump (PLR Pump)

    International Nuclear Information System (INIS)

    Fukushima, Naoki; Koshiba, Koremutsu

    1995-01-01

    The mechanical seal for a Primary Loop Recirculation Pump (PLR Pump) is an important part of a BWR plant. This study describes a new mechanical seal tester developed to certify mechanical seal performance before installation in a PLR Pump on site. (author)

  19. The health preoccupation diagnostic interview: inter-rater reliability of a structured interview for diagnostic assessment of DSM-5 somatic symptom disorder and illness anxiety disorder.

    Science.gov (United States)

    Axelsson, Erland; Andersson, Erik; Ljótsson, Brjánn; Wallhed Finn, Daniel; Hedman, Erik

    2016-06-01

    Somatic symptom disorder (SSD) and illness anxiety disorder (IAD) are two new diagnoses introduced in the DSM-5. There is a need for reliable instruments to facilitate the assessment of these disorders. We therefore developed a structured diagnostic interview, the Health Preoccupation Diagnostic Interview (HPDI), which we hypothesized would reliably differentiate between SSD, IAD, and no diagnosis. Persons with clinically significant health anxiety (n = 52) and healthy controls (n = 52) were interviewed using the HPDI. Diagnoses were then compared with those made by an independent assessor, who listened to audio recordings of the interviews. Ratings generally indicated moderate to almost perfect inter-rater agreement, as illustrated by an overall Cohen's κ of .85. Disagreements primarily concerned (a) the severity of somatic symptoms, (b) the differential diagnosis of panic disorder, and (c) SSD specifiers. We conclude that the HPDI can be used to reliably diagnose DSM-5 SSD and IAD.

  20. Initial Development of an Electronic Testis Rigidity Tester

    Directory of Open Access Journals (Sweden)

    Petros Mirilas

    2011-01-01

    Full Text Available We aimed to develop our previously presented mechanical device, the Testis Rigidity Tester (TRT, into an electronic system (Electronic Testis Rigidity Tester, ETRT by applying tactile imaging, which has been used successfully with other solid organs. A measuring device, located at the front end of the ETRT incorporates a tactile sensor comprising an array of microsensors. By application of a predetermined deformation of 2 mm, increased pressure alters linearly the resistance of each microsensor, producing changes of voltage. These signals were amplified, filtered, and digitized, and then processed by an electronic collector system, which presented them as a color-filled contour plot of the area of the testis coming into contact with the sensor. Testis models of different rigidity served for initial evaluation of ETRT; their evacuated central spaces contained different, increasing glue masses. An independent method of rigidity measurement, using an electric weight scale and a micrometer, showed that the more the glue injected, the greater the force needed for a 2-mm deformation. In a preliminary test, a single sensor connected to a multimeter showed similar force measurement for the same deformation in these phantoms. For each of the testis models compressed in the same manner, the ETRT system offered a map of pressures, represented by a color scale within the contour plot of the contact area with the sensor. ETRT found certain differences in rigidity between models that had escaped detection by a blind observer. ETRT is easy to use and provides a color-coded “insight“ of the testis internal structure. After experimental testing, it could be valuable in intraoperative evaluation of testes, so that the surgeon can decide about orchectomy or orcheopexy.

  1. The Development and Application of Simulative Insulation Resistance Tester

    Science.gov (United States)

    Jia, Yan; Chai, Ziqi; Wang, Bo; Ma, Hao

    2018-02-01

    The insulation state determines the performance and insulation life of electrical equipment, so it has to be judged in a timely and accurate manner. Insulation resistance test, as the simplest and most basic test of high voltage electric tests, can measure the insulation resistance and absorption ratio which are effective criterion of part or whole damp or dirty, breakdown, severe overheating aging and other insulation defects. It means that the electrical test personnel need to be familiar with the principle of insulation resistance test, and able to operate the insulation resistance tester correctly. At present, like the insulation resistance test, most of electrical tests are trained by physical devices with the real high voltage. Although this allows the students to truly experience the test process and notes on security, it also has certain limitations in terms of safety and test efficiency, especially for a large number of new staves needing induction training every year. This paper presents a new kind of electrical test training system based on the simulative device of dielectric loss measurement and simulative electrical testing devices. It can not only overcome the defects of current training methods, but also provide other advantages in economical efficiency and scalability. That makes it possible for the system to be allied in widespread.

  2. High power klystrons for efficient reliable high power amplifiers

    Science.gov (United States)

    Levin, M.

    1980-11-01

    This report covers the design of reliable high efficiency, high power klystrons which may be used in both existing and proposed troposcatter radio systems. High Power (10 kW) klystron designs were generated in C-band (4.4 GHz to 5.0 GHz), S-band (2.5 GHz to 2.7 GHz), and L-band or UHF frequencies (755 MHz to 985 MHz). The tubes were designed for power supply compatibility and use with a vapor/liquid phase heat exchanger. Four (4) S-band tubes were developed in the course of this program along with two (2) matching focusing solenoids and two (2) heat exchangers. These tubes use five (5) tuners with counters which are attached to the focusing solenoids. A reliability mathematical model of the tube and heat exchanger system was also generated.

  3. Evaluation of Next-Generation Vision Testers for Aeromedical Certification of Aviation Personnel

    Science.gov (United States)

    2009-07-01

    measure distant, intermediate, and near acuity. The slides are essentially abbreviated versions of the Early Treatment for Diabetic Retinopathy Study...over, requiring intermediate vision testing and 12 were color deficient. Analysis was designed to detect statistically significant differences between...Vertical Phoria (Right & Left Hyperphoria) Test scores from each of the vision testers were collated and analyzed. Analysis was designed to detect

  4. Reliability and main findings of the FEES-Tensilon Test in patients with myasthenia gravis and dysphagia.

    Science.gov (United States)

    Im, Sun; Suntrup-Krueger, Sonja; Colbow, Sigrid; Sauer, Sonja; Claus, Inga; Meuth, Sven G; Dziewas, Rainer; Warnecke, Tobias

    2018-05-26

    Diagnosis of pharyngeal dysphagia caused by myasthenia gravis (MG) based on clinical examination alone is often challenging. Flexible endoscopic evaluation of swallowing (FEES) combined with Tensilon (edrophonium) application, referred to as the FEES-Tensilon Test, was developed to improve diagnostic accuracy and to detect the main symptoms of pharyngeal dysphagia in MG. Here we investigated inter- and intra-rater reliability of the FEES-Tensilon Test and analyzed the main endoscopic findings. Four experienced raters reviewed a total of 20 FEES-Tensilon-Test videos in randomized order. Residue severity was graded at 4 different pharyngeal spaces before and after Tensilon administration. All interpretations were performed twice per rater, 4 weeks apart (a total of 160 scorings). Intra-rater test-retest reliability and inter-rater reliability levels were calculated. The most frequent FEES findings in MG patients before Tensilon application were prominent residues of semi solids spread all over the hypopharynx in varying locations. The reliability level in the interpretation of the FEES-Tensilon test was excellent regardless of the raters' profession or years of experience with FEES. All 4 raters showed high inter- and intra- reliability levels in interpreting the FEES-Tensilon Test based on residue clearance (kappa=0.922, 0.981). Degree of residue normalization in the vallecular space after Tensilon application showed the highest inter- and intra-rater reliability level (kappa=0.863, 0.957) followed by the epiglottis (kappa=0.813, 0.946) and pyriform sinuses (kappa=0.836, 0.929). Interpretation of the FEES-Tensilon Test based on residue severity and degree of Tensilon clearance, especially in the vallecular space, is consistent and reliable. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  5. Evaluating the reliability of an injury prevention screening tool: Test-retest study.

    Science.gov (United States)

    Gittelman, Michael A; Kincaid, Madeline; Denny, Sarah; Wervey Arnold, Melissa; FitzGerald, Michael; Carle, Adam C; Mara, Constance A

    2016-10-01

    A standardized injury prevention (IP) screening tool can identify family risks and allow pediatricians to address behaviors. To assess behavior changes on later screens, the tool must be reliable for an individual and ideally between household members. Little research has examined the reliability of safety screening tool questions. This study utilized test-retest reliability of parent responses on an existing IP questionnaire and also compared responses between household parents. Investigators recruited parents of children 0 to 1 year of age during admission to a tertiary care children's hospital. When both parents were present, one was chosen as the "primary" respondent. Primary respondents completed the 30-question IP screening tool after consent, and they were re-screened approximately 4 hours later to test individual reliability. The "second" parent, when present, only completed the tool once. All participants received a 10-dollar gift card. Cohen's Kappa was used to estimate test-retest reliability and inter-rater agreement. Standard test-retest criteria consider Kappa values: 0.0 to 0.40 poor to fair, 0.41 to 0.60 moderate, 0.61 to 0.80 substantial, and 0.81 to 1.00 as almost perfect reliability. One hundred five families participated, with five lost to follow-up. Thirty-two (30.5%) parent dyads completed the tool. Primary respondents were generally mothers (88%) and Caucasian (72%). Test-retest of the primary respondents showed their responses to be almost perfect; average 0.82 (SD = 0.13, range 0.49-1.00). Seventeen questions had almost perfect test-retest reliability and 11 had substantial reliability. However, inter-rater agreement between household members for 12 objective questions showed little agreement between responses; inter-rater agreement averaged 0.35 (SD = 0.34, range -0.19-1.00). One question had almost perfect inter-rater agreement and two had substantial inter-rater agreement. The IP screening tool used by a single individual had excellent

  6. A study on the reliability evaluation of shot peened aluminium alloy using accelerated life test

    International Nuclear Information System (INIS)

    Nam, Ji Hun; Cheong, Seong Kyun; Kang, Min Woo

    2006-01-01

    In this paper, the concept of accelerated life test, which is a popular research field nowadays, is applied to the shot peened material. To predict the efficient and exact room temperature fatigue characteristics from the high temperature fatigue data, the adequate accelerated model is investigated. Ono type rotary bending fatigue tester and high temperature chamber were used for the experiment. Room temperature fatigue lives were predicted by applying accelerated models and doing reliability evaluation. Room temperature fatigue tests were accomplished to check the effectiveness of predicted data and the adequate accelerated life test models were presented by considering errors. Experimental result using Arrhenius model, fatigue limit obtain almost 5.45% of error, inverse power law has about 1.36% of error, so we found that inverse power law is applied well to temperature-life relative of shot peended material

  7. Reliability in endoscopic diagnosis of portal hypertensive gastropathy

    Science.gov (United States)

    de Macedo, George Fred Soares; Ferreira, Fabio Gonçalves; Ribeiro, Maurício Alves; Szutan, Luiz Arnaldo; Assef, Mauricio Saab; Rossini, Lucio Giovanni Battista

    2013-01-01

    AIM: To analyze reliability among endoscopists in diagnosing portal hypertensive gastropathy (PHG) and to determine which criteria from the most utilized classifications are the most suitable. METHODS: From January to July 2009, in an academic quaternary referral center at Santa Casa of São Paulo Endoscopy Service, Brazil, we performed this single-center prospective study. In this period, we included 100 patients, including 50 sequential patients who had portal hypertension of various etiologies; who were previously diagnosed based on clinical, laboratory and imaging exams; and who presented with esophageal varices. In addition, our study included 50 sequential patients who had dyspeptic symptoms and were referred for upper digestive endoscopy without portal hypertension. All subjects underwent upper digestive endoscopy, and the images of the exam were digitally recorded. Five endoscopists with more than 15 years of experience answered an electronic questionnaire, which included endoscopic criteria from the 3 most commonly used Portal Hypertensive Gastropathy classifications (McCormack, NIEC and Baveno) and the presence of elevated or flat antral erosive gastritis. All five endoscopists were blinded to the patients’ clinical information, and all images of varices were deliberately excluded for the analysis. RESULTS: The three most common etiologies of portal hypertension were schistosomiasis (36%), alcoholic cirrhosis (20%) and viral cirrhosis (14%). Of the 50 patients with portal hypertension, 84% were Child A, 12% were Child B, 4% were Child C, 64% exhibited previous variceal bleeding and 66% were previously endoscopic treated. The endoscopic parameters, presence or absence of mosaic-like pattern, red point lesions and cherry-red spots were associated with high inter-observer reliability and high specificity for diagnosing Portal Hypertensive Gastropathy. Sensitivity, specificity and reliability for the diagnosis of PHG (%) were as follows: mosaic-like pattern

  8. Reliability of injury grading systems for patients with blunt splenic trauma.

    Science.gov (United States)

    Olthof, D C; van der Vlies, C H; Scheerder, M J; de Haan, R J; Beenen, L F M; Goslings, J C; van Delden, O M

    2014-01-01

    The most widely used grading system for blunt splenic injury is the American Association for the Surgery of Trauma (AAST) organ injury scale. In 2007 a new grading system was developed. This 'Baltimore CT grading system' is superior to the AAST classification system in predicting the need for angiography and embolization or surgery. The objective of this study was to assess inter- and intraobserver reliability between radiologists in classifying splenic injury according to both grading systems. CT scans of 83 patients with blunt splenic injury admitted between 1998 and 2008 to an academic Level 1 trauma centre were retrospectively reviewed. Inter and intrarater reliability were expressed in Cohen's or weighted Kappa values. Overall weighted interobserver Kappa coefficients for the AAST and 'Baltimore CT grading system' were respectively substantial (kappa=0.80) and almost perfect (kappa=0.85). Average weighted intraobserver Kappa's values were in the 'almost perfect' range (AAST: kappa=0.91, 'Baltimore CT grading system': kappa=0.81). The present study shows that overall the inter- and intraobserver reliability for grading splenic injury according to the AAST grading system and 'Baltimore CT grading system' are equally high. Because of the integration of vascular injury, the 'Baltimore CT grading system' supports clinical decision making. We therefore recommend use of this system in the classification of splenic injury. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Isotope Fuels Impact Tester (IFIT)

    International Nuclear Information System (INIS)

    Frantz, C.E.; Taylor, J.W.; Court, D.B.

    1975-07-01

    The Isotope Fuels Impact Tester (IFIT) is used for safely impacting 238 PuO 2 heat sources that have been heated to 2000 0 C. Impact velocities reach 300 m/s (1000 ft/s). A gas gun with a 178-mm (7-in.) bore is used to accelerate the heat source, which is heated by a furnace built into the projectile. Double containment of the impacted heat source is obtained by two vessels that are sealed directly to the gun muzzle. The impact occurs in the inner vessel, and parts of the projectile jam into and thereby close each vessel. The inner vessel, containing the impacted heat source, is removed from the gun and is placed inside a glovebox for disassembly and heat-source recovery. IFIT's modular structure makes it versatile and adaptable to many types of tests. Many applications have demonstrated its versatility and, more important, its capability for impacting 238 PuO 2 heat sources safely. An approximate theoretical relation is used to predict proper conditions for achieving desired impact velocities. Bore lubricants and projectile-seal design are also important for achieving proper impact velocities

  10. Line tester analysis of yield and yield related attributed in different sunflower genotypes

    International Nuclear Information System (INIS)

    Din, S.U.; Khan, M.A.; Usman, K.; Sayal, O.U.

    2014-01-01

    This paper encompasses the study of line * tester analysis to chalk out genetic implications regarding yield and yield relating components in different genotypes of sunflower. Eight parents (four CMS lines and four restorers) along with their sixteen F1 hybrids were considered and planted in Randomized Complete Block Design (RCBD) replicated thrice at experimental area of Oilseed Research Program, National Agriculture Research Centre (NARC), Islamabad, Pakistan in 2011. Combining ability for some important morphological traits included days to flower initiation, days to flower completion, days to maturity, plant height, head diameter and seed yield plant-1. In this concern general combining ability (GCA), reciprocals combining ability (RCA) and specific combining ability (SCA) for all traits were studied. The GCA and SCA variances due to lines and testers interaction were significant for all the characters. However, the magnitude of GCAs from CMS lines (females) and restorers (pollinators) were higher than the SCA indicating preponderance of additive genes in the expression of all the traits. Among the lines, CMS-HA-54 whereas in testers, RHP-71, by manifesting maximum GCA effects were considered as the best general combiners for almost all the traits indicating the presence of more additive gene effects in these parents, therefore may serve as potential parents for hybridization and to improve the characters studied. Among the F1 hybrids, CMS HA-99 * RHP-76 (1.54, 212.65) and CMS HA-101 * RHP-73 (0.91, 432.73) were found as the best specific combiners for head or capitulum and seed yield. Hence, if farming community and researchers include these hybrids in their selection and hybridization program for the trait under study optimum result may be obtained. (author)

  11. Effects of questionnaire-based diagnosis and training on inter-rater reliability among practitioners of traditional Chinese medicine.

    Science.gov (United States)

    Mist, Scott; Ritenbaugh, Cheryl; Aickin, Mikel

    2009-07-01

    To investigate whether a training process that focused on a questionnaire-based diagnosis in Traditional Chinese Medicine (TCM), and developing diagnostic consensus, would improve the agreement of TCM diagnoses among 10 TCM practitioners evaluating patients with temporomandibular joint disorder (TMJD). Evaluation of a diagnostic training program at the Department of Family and Community Medicine, University of Arizona, Tucson, Arizona, and the Oregon College of Oriental Medicine, Portland, Oregon. Screened participants for a study of TCM for TMJD. PRACTITIONERS: Ten (10) licensed acupuncturists with a minimum of 5 years licensure and education in Chinese herbs. A training session using a questionnaire-based diagnostic form was conducted, followed by waves of diagnostic sessions. Between sessions, practitioners discussed the results of the previous round of participants with a focus on reducing variability in primary diagnosis and severity rating of each diagnosis: 3 waves of 5 patients were assessed by 4 practitioner pairs for a total of 120 diagnoses. At 18 months, practitioners completed a recalibration exercise with a similar format with a total of 32 diagnoses. These diagnoses were then examined with respect to the rate of agreement among the 10 practitioners using inter-rater correlations and kappas. The inter-rater correlation with respect to the TCM diagnoses among the 10 practitioners increased from 0.112 to 0.618 with training. Statistically significant improvements were found between the baseline and 18 month exercises (p reliability of TCM diagnosis may be improved through a training process and a questionnaire-based diagnosis process. The improvements varied by diagnosis, with the greatest congruence among primary and more severe diagnoses. Future TCM studies should consider including calibration training to improve the validity of results.

  12. Effect of knee angle on neuromuscular assessment of plantar flexor muscles: A reliability study

    Science.gov (United States)

    Cornu, Christophe; Jubeau, Marc

    2018-01-01

    Introduction This study aimed to determine the intra- and inter-session reliability of neuromuscular assessment of plantar flexor (PF) muscles at three knee angles. Methods Twelve young adults were tested for three knee angles (90°, 30° and 0°) and at three time points separated by 1 hour (intra-session) and 7 days (inter-session). Electrical (H reflex, M wave) and mechanical (evoked and maximal voluntary torque, activation level) parameters were measured on the PF muscles. Intraclass correlation coefficients (ICC) and coefficients of variation were calculated to determine intra- and inter-session reliability. Results The mechanical measurements presented excellent (ICC>0.75) intra- and inter-session reliabilities regardless of the knee angle considered. The reliability of electrical measurements was better for the 90° knee angle compared to the 0° and 30° angles. Conclusions Changes in the knee angle may influence the reliability of neuromuscular assessments, which indicates the importance of considering the knee angle to collect consistent outcomes on the PF muscles. PMID:29596480

  13. Intra- and inter-rater reliability of movement and palpation tests in patients with neck pain: A systematic review.

    Science.gov (United States)

    Jonsson, Anders; Rasmussen-Barr, Eva

    2018-03-01

    Neck pain is common and often becomes chronic. Various clinical tests of the cervical spine are used to direct and evaluate treatment. This systematic review aimed to identify studies examining the intra- and/or interrater reliability of tests used in clinical examination of patients with neck pain. A database search up to April 2016 was conducted in PubMed, CINAHL, and AMED. The Quality Appraisal of Reliability Studies Checklist (QAREL) was used to assess risk of bias. Eleven studies were included, comprising tests of active and passive movement and pain evaluating participants with ongoing neck pain. One study was assessed with a low risk of bias, three with medium risk, while the rest were assessed with high risk of bias. The results showed differing reliabilities for the included tests ranging from poor to almost perfect. In conclusion, active movement and pain for pain or mobility overall presented acceptable to very good reliability (Kappa >0.40); while passive intervertebral tests had lower Kappa values, suggesting poor reliability. It may be a coincidence that the studies indicating very good reliability tended to be of higher quality (low to moderate risk of bias), while studies finding poor reliability tended to be of lower quality (high risk of bias). Regardless, the current recommendation from this review would suggest the clinical use of tests with acceptable reliability and avoiding the use of tests that have been shown to not be reliable. Finally, it is critical that all future reliability studies are of higher quality with low risk of bias.

  14. Reliability and validity of a nutrition and physical activity environmental self-assessment for child care

    Directory of Open Access Journals (Sweden)

    Ammerman Alice S

    2007-07-01

    Full Text Available Abstract Background Few assessment instruments have examined the nutrition and physical activity environments in child care, and none are self-administered. Given the emerging focus on child care settings as a target for intervention, a valid and reliable measure of the nutrition and physical activity environment is needed. Methods To measure inter-rater reliability, 59 child care center directors and 109 staff completed the self-assessment concurrently, but independently. Three weeks later, a repeat self-assessment was completed by a sub-sample of 38 directors to assess test-retest reliability. To assess criterion validity, a researcher-administered environmental assessment was conducted at 69 centers and was compared to a self-assessment completed by the director. A weighted kappa test statistic and percent agreement were calculated to assess agreement for each question on the self-assessment. Results For inter-rater reliability, kappa statistics ranged from 0.20 to 1.00 across all questions. Test-retest reliability of the self-assessment yielded kappa statistics that ranged from 0.07 to 1.00. The inter-quartile kappa statistic ranges for inter-rater and test-retest reliability were 0.45 to 0.63 and 0.27 to 0.45, respectively. When percent agreement was calculated, questions ranged from 52.6% to 100% for inter-rater reliability and 34.3% to 100% for test-retest reliability. Kappa statistics for validity ranged from -0.01 to 0.79, with an inter-quartile range of 0.08 to 0.34. Percent agreement for validity ranged from 12.9% to 93.7%. Conclusion This study provides estimates of criterion validity, inter-rater reliability and test-retest reliability for an environmental nutrition and physical activity self-assessment instrument for child care. Results indicate that the self-assessment is a stable and reasonably accurate instrument for use with child care interventions. We therefore recommend the Nutrition and Physical Activity Self-Assessment for

  15. The Surgical Safety Checklist and Teamwork Coaching Tools: a study of inter-rater reliability.

    Science.gov (United States)

    Huang, Lyen C; Conley, Dante; Lipsitz, Stu; Wright, Christopher C; Diller, Thomas W; Edmondson, Lizabeth; Berry, William R; Singer, Sara J

    2014-08-01

    To assess the inter-rater reliability (IRR) of two novel observation tools for measuring surgical safety checklist performance and teamwork. Data surgical safety checklists can promote adherence to standards of care and improve teamwork in the operating room. Their use has been associated with reductions in mortality and other postoperative complications. However, checklist effectiveness depends on how well they are performed. Authors from the Safe Surgery 2015 initiative developed a pair of novel observation tools through literature review, expert consultation and end-user testing. In one South Carolina hospital participating in the initiative, two observers jointly attended 50 surgical cases and independently rated surgical teams using both tools. We used descriptive statistics to measure checklist performance and teamwork at the hospital. We assessed IRR by measuring percent agreement, Cohen's κ, and weighted κ scores. The overall percent agreement and κ between the two observers was 93% and 0.74 (95% CI 0.66 to 0.79), respectively, for the Checklist Coaching Tool and 86% and 0.84 (95% CI 0.77 to 0.90) for the Surgical Teamwork Tool. Percent agreement for individual sections of both tools was 79% or higher. Additionally, κ scores for six of eight sections on the Checklist Coaching Tool and for two of five domains on the Surgical Teamwork Tool achieved the desired 0.7 threshold. However, teamwork scores were high and variation was limited. There were no significant changes in the percent agreement or κ scores between the first 10 and last 10 cases observed. Both tools demonstrated substantial IRR and required limited training to use. These instruments may be used to observe checklist performance and teamwork in the operating room. However, further refinement and calibration of observer expectations, particularly in rating teamwork, could improve the utility of the tools. Published by the BMJ Publishing Group Limited. For permission to use (where not already

  16. Evaluation of dampers using a resonance adhesion tester

    Directory of Open Access Journals (Sweden)

    Stanislav Koláček

    2013-01-01

    Full Text Available This paper describes the diagnostics of dampers using resonant adhesion tester. This kind of test is non-invasive and evaluation is based on the EUSAMA methodology. The main goals of this method were to practically measure and evaluate technical condition of the shock absorbers. However, this method does not measure only damper properties, but the whole axle, too. During measurements, one must take into account the fact that the results can be easily influenced by external factors. These include e.g. wrong tire pressure, different kind of shock absorbers, and tires. The actual testing revealed that the measurement results are also influenced by bad condition of the vehicle axles. If we eliminate all these draw-backs, dampers testing can be very accurate.

  17. Reliability analysis of the epidural spinal cord compression scale.

    Science.gov (United States)

    Bilsky, Mark H; Laufer, Ilya; Fourney, Daryl R; Groff, Michael; Schmidt, Meic H; Varga, Peter Paul; Vrionis, Frank D; Yamada, Yoshiya; Gerszten, Peter C; Kuklo, Timothy R

    2010-09-01

    The evolution of imaging techniques, along with highly effective radiation options has changed the way metastatic epidural tumors are treated. While high-grade epidural spinal cord compression (ESCC) frequently serves as an indication for surgical decompression, no consensus exists in the literature about the precise definition of this term. The advancement of the treatment paradigms in patients with metastatic tumors for the spine requires a clear grading scheme of ESCC. The degree of ESCC often serves as a major determinant in the decision to operate or irradiate. The purpose of this study was to determine the reliability and validity of a 6-point, MR imaging-based grading system for ESCC. To determine the reliability of the grading scale, a survey was distributed to 7 spine surgeons who participate in the Spine Oncology Study Group. The MR images of 25 cervical or thoracic spinal tumors were distributed consisting of 1 sagittal image and 3 axial images at the identical level including T1-weighted, T2-weighted, and Gd-enhanced T1-weighted images. The survey was administered 3 times at 2-week intervals. The inter- and intrarater reliability was assessed. The inter- and intrarater reliability ranged from good to excellent when surgeons were asked to rate the degree of spinal cord compression using T2-weighted axial images. The T2-weighted images were superior indicators of ESCC compared with T1-weighted images with and without Gd. The ESCC scale provides a valid and reliable instrument that may be used to describe the degree of ESCC based on T2-weighted MR images. This scale accounts for recent advances in the treatment of spinal metastases and may be used to provide an ESCC classification scheme for multicenter clinical trial and outcome studies.

  18. Feasibility and reliability of a newly developed antenatal risk score card in routine care

    NARCIS (Netherlands)

    E. Birnie; E.A.P. Steegers; Drs. H.W. Torij; M.J. Veen; J. Poeran; G.J. Bonsel

    2015-01-01

    A population-based cross-sectional study (feasibility) and a cohort study (inter-rater reliability) to study in routine care the feasibility and inter-rater reliability of the Rotterdam Reproductive Risk Reduction risk score card (R4U), a new semi-quantitative score card for use during the antenatal

  19. Infant Physical Attractiveness, Affect, Temperament, and Gender in Relation to Tester Behavior

    OpenAIRE

    Hart, Andrea D.

    1996-01-01

    Easily observable infant characteristics have been shown to influence others; perceptions of infant competence. This study examined the relation between infant characteristics and a tester's willingness to repeat opportunities for the infant to pass items during administration of a cognitive test. Results showed that infant physical attractiveness was related to lower elicited infant performance (the ratio of items initially failed). Positive affect was related to higher test scores. Because ...

  20. High-reliability computing for the smarter planet

    International Nuclear Information System (INIS)

    Quinn, Heather M.; Graham, Paul; Manuzzato, Andrea; Dehon, Andre

    2010-01-01

    The geometric rate of improvement of transistor size and integrated circuit performance, known as Moore's Law, has been an engine of growth for our economy, enabling new products and services, creating new value and wealth, increasing safety, and removing menial tasks from our daily lives. Affordable, highly integrated components have enabled both life-saving technologies and rich entertainment applications. Anti-lock brakes, insulin monitors, and GPS-enabled emergency response systems save lives. Cell phones, internet appliances, virtual worlds, realistic video games, and mp3 players enrich our lives and connect us together. Over the past 40 years of silicon scaling, the increasing capabilities of inexpensive computation have transformed our society through automation and ubiquitous communications. In this paper, we will present the concept of the smarter planet, how reliability failures affect current systems, and methods that can be used to increase the reliable adoption of new automation in the future. We will illustrate these issues using a number of different electronic devices in a couple of different scenarios. Recently IBM has been presenting the idea of a 'smarter planet.' In smarter planet documents, IBM discusses increased computer automation of roadways, banking, healthcare, and infrastructure, as automation could create more efficient systems. A necessary component of the smarter planet concept is to ensure that these new systems have very high reliability. Even extremely rare reliability problems can easily escalate to problematic scenarios when implemented at very large scales. For life-critical systems, such as automobiles, infrastructure, medical implantables, and avionic systems, unmitigated failures could be dangerous. As more automation moves into these types of critical systems, reliability failures will need to be managed. As computer automation continues to increase in our society, the need for greater radiation reliability is necessary

  1. High-reliability computing for the smarter planet

    Energy Technology Data Exchange (ETDEWEB)

    Quinn, Heather M [Los Alamos National Laboratory; Graham, Paul [Los Alamos National Laboratory; Manuzzato, Andrea [UNIV OF PADOVA; Dehon, Andre [UNIV OF PENN; Carter, Nicholas [INTEL CORPORATION

    2010-01-01

    The geometric rate of improvement of transistor size and integrated circuit performance, known as Moore's Law, has been an engine of growth for our economy, enabling new products and services, creating new value and wealth, increasing safety, and removing menial tasks from our daily lives. Affordable, highly integrated components have enabled both life-saving technologies and rich entertainment applications. Anti-lock brakes, insulin monitors, and GPS-enabled emergency response systems save lives. Cell phones, internet appliances, virtual worlds, realistic video games, and mp3 players enrich our lives and connect us together. Over the past 40 years of silicon scaling, the increasing capabilities of inexpensive computation have transformed our society through automation and ubiquitous communications. In this paper, we will present the concept of the smarter planet, how reliability failures affect current systems, and methods that can be used to increase the reliable adoption of new automation in the future. We will illustrate these issues using a number of different electronic devices in a couple of different scenarios. Recently IBM has been presenting the idea of a 'smarter planet.' In smarter planet documents, IBM discusses increased computer automation of roadways, banking, healthcare, and infrastructure, as automation could create more efficient systems. A necessary component of the smarter planet concept is to ensure that these new systems have very high reliability. Even extremely rare reliability problems can easily escalate to problematic scenarios when implemented at very large scales. For life-critical systems, such as automobiles, infrastructure, medical implantables, and avionic systems, unmitigated failures could be dangerous. As more automation moves into these types of critical systems, reliability failures will need to be managed. As computer automation continues to increase in our society, the need for greater radiation reliability is

  2. Estimates of genetic parameters from line x tester mating design for some quantitative traits in upload cotton, gossypium hirsutum L

    International Nuclear Information System (INIS)

    Baloch, M.H.; Kumbher, M.B.; Jatoi, W.A.

    2008-01-01

    Combining abilities of cotton varieties were evaluated using a line x tester design with eight lines and 4 testers. Good performance combination was found between the varieties CRIS-134 and BH-147. The former was a good candidate for fibre length improvement and the latter, a good parent for yield improvement. The specific combining ability suggested that both additive and dominant genes controlled the characters. Hybrid performance per se may be used to predict the parental performance for specific combining ability and thus for hybrid crop development. (author)

  3. The Reliability of Quality of Upper Extremity Skills Test in Children with Cerebral Palsy

    Directory of Open Access Journals (Sweden)

    Nazila Akbar-Fahimi

    2012-01-01

    Full Text Available Objective: The aim of this study was to survey the reliability of Intra-rater and Inter-rater with and without video camera assessment in children with spastic cerebral palsy. Materials & Methods: In this cross-sectional study, we validate the Quality of Upper Extremity Skill Test questionnaire. Fifty children with hemiplegia aged 19 to 95 months (mean age 61.31 ± 25.7 month were enrolled in our study using non random available approach. After obtaining parents’ consent, intra-rater assessment was performed in one session and intera rater assessment with camera after 10 days. Then, the third examiner did the reassessment using film observation of 46 children from 50. Spearman correlation for survey the reliability of intra-rater & inter rater with & without video recording assessment & gross motor function classification system 66 for determined functionality of child were used. Results: Intra-rater correlation was 0.774-0.996, Inter-rater correlation was 0.663-0.998 and correlation for video camera assessment was 0.710-0.974 for the first and third evaluation and 0.652-0.938 for second and third evaluation. P value for sub scales and total score was P<0.01. Conclusion: There is a high correlation in Intra rater and inter rater assessment with and without video recording in Quality of Upper Extremity Skill Test in children with cerebral palsy. So that it can be used as a reliable test to evaluate Quality of Upper Extremity Skills in these children.

  4. Reliability of radiographic measurements for acute distal radius fractures

    International Nuclear Information System (INIS)

    Watson, Narelle J.; Asadollahi, Saeed; Parrish, Frank; Ridgway, Jacqueline; Tran, Phong; Keating, Jennifer L.

    2016-01-01

    The management of distal radial fractures is guided by the interpretation of radiographic findings. The aim of this investigation was to determine the intra- and inter-observer reliability of eight traditionally reported anatomic radiographic parameters in adults with an acute distal radius fracture. Five observers participated. All were routinely involved in making treatment decisions based on distal radius fracture radiographs. Observers performed independent repeated measurements on 30 radiographs for eight anatomical parameters: dorsal shift (mm), intra-articular gap (mm), intra-articular step (mm), palmar tilt (degrees), radial angle (degrees), radial height (mm), radial shift (mm), ulnar variance (mm). Intraclass correlation coefficients (ICCs) and the magnitude of retest errors were calculated. Measurement reliability was summarised as high (ICC > 0.80), moderate (0.60–0.80) or low (<0.60). Intra-observer reliability was high for dorsal shift and palmar tilt; moderate for radial angle, radial height, ulnar variance and radial shift; and low for intra-articular gap and step. Inter-observer reliability was high for palmar tilt; moderate for dorsal shift, ulnar variance, radial angle and radial height; and low for radial shift, intra-articular gap and step. Error magnitude (95 % confidence interval) was within 1–2 mm for intra-articular gap and step, 2–4 mm for ulnar variance, 4–6 mm for radial shift, dorsal shift and radial height, and 6–8° for radial angle and palmar tilt. Based on previous reports of critical values for palmar tilt, ulnar variance and radial angle, error margins appear small enough for measurements to be useful in guiding treatment decisions. Our findings indicate that clinicians cannot reliably measure values ≤1 mm for intra-articular gap and step when interpreting radiographic parameters using the standardised methods investigated in this study. As a guide for treatment selection, palmar tilt, ulnar variance and radial angle

  5. Assessment of the severity of dementia: validity and reliability of the Chinese (Cantonese) version of the Hierarchic Dementia Scale (CV-HDS).

    Science.gov (United States)

    Poon, Vickie Wan-kei; Lam, Linda Chiu-wa; Wong, Samuel Yeung-shan

    2008-09-01

    With the rapid growth of the older population, early detection of cognitive deficits is crucial in slowing down functional deterioration of the elderly persons. To examine the validity and reliability of the Chinese (Cantonese) version of the Hierarchic Dementia Scale (CV-HDS) for Chinese older persons in Hong Kong. The HDS was translated into Cantonese Chinese. The content and cultural validity were evaluated by six expert panel members. Sixty-two participants with diagnosis of dementia were recruited for evaluation. Inter-rater reliability, test-retest reliability, internal consistency and concurrent validity were examined. The CV-HDS demonstrated satisfactory psychometric properties. inter-rater reliability and test-retest reliability were high (alpha=0.89 and alpha=0.94 respectively). High value of Cronbach's alpha (alpha=0.94) demonstrated good internal consistency. The concurrent validity of CV-HDS, through correlation with its scores with that of the Chinese version of Mini Mental Status Examination, was established (ranged from r=0.58 to r=0.78, pCantonese speaking Chinese people with dementia. It facilitates treatment planning to optimize the effects of functional training and rehabilitation.

  6. Inter-Rater Reliability and Downstream Financial Implications of Electrocardiography Screening in Young Athletes.

    Science.gov (United States)

    Dhutia, Harshil; Malhotra, Aneil; Yeo, Tee Joo; Ster, Irina Chis; Gabus, Vincent; Steriotis, Alexandros; Dores, Helder; Mellor, Greg; García-Corrales, Carmen; Ensam, Bode; Jayalapan, Viknesh; Ezzat, Vivienne Anne; Finocchiaro, Gherardo; Gati, Sabiha; Papadakis, Michael; Tome-Esteban, Maria; Sharma, Sanjay

    2017-08-01

    Preparticipation screening for cardiovascular disease in young athletes with electrocardiography is endorsed by the European Society of Cardiology and several major sporting organizations. One of the concerns of the ECG as a screening test in young athletes relates to the potential for variation in interpretation. We investigated the degree of variation in ECG interpretation in athletes and its financial impact among cardiologists of differing experience. Eight cardiologists (4 with experience in screening athletes) each reported 400 ECGs of consecutively screened young athletes according to the 2010 European Society of Cardiology recommendations, Seattle criteria, and refined criteria. Cohen κ coefficient was used to calculate interobserver reliability. Cardiologists proposed secondary investigations after ECG interpretation, the costs of which were based on the UK National Health Service tariffs. Inexperienced cardiologists were more likely to classify an ECG as abnormal compared with experienced cardiologists (odds ratio, 1.44; 95% confidence interval, 1.03-2.02). Modification of ECG interpretation criteria improved interobserver reliability for categorizing an ECG as abnormal from poor (2010 European Society of Cardiology recommendations; κ=0.15) to moderate (refined criteria; κ=0.41) among inexperienced cardiologists; however, interobserver reliability was moderate for all 3 criteria among experienced cardiologists (κ=0.40-0.53). Inexperienced cardiologists were more likely to refer athletes for further evaluation compared with experienced cardiologists (odds ratio, 4.74; 95% confidence interval, 3.50-6.43) with poorer interobserver reliability (κ=0.22 versus κ=0.47). Interobserver reliability for secondary investigations after ECG interpretation ranged from poor to fair among inexperienced cardiologists (κ=0.15-0.30) and fair to moderate among experienced cardiologists (κ=0.21-0.46). The cost of cardiovascular evaluation per athlete was $175 (95

  7. Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program

    Science.gov (United States)

    Sled, Elizabeth A.; Sheehy, Lisa M.; Felson, David T.; Costigan, Patrick A.; Lam, Miu; Cooke, T. Derek V.

    2010-01-01

    The objective of the study was to evaluate the reliability of frontal plane lower limb alignment measures using a landmark-based method by (1) comparing inter- and intra-reader reliability between measurements of alignment obtained manually with those using a computer program, and (2) determining inter- and intra-reader reliability of computer-assisted alignment measures from full-limb radiographs. An established method for measuring alignment was used, involving selection of 10 femoral and tibial bone landmarks. 1) To compare manual and computer methods, we used digital images and matching paper copies of five alignment patterns simulating healthy and malaligned limbs drawn using AutoCAD. Seven readers were trained in each system. Paper copies were measured manually and repeat measurements were performed daily for 3 days, followed by a similar routine with the digital images using the computer. 2) To examine the reliability of computer-assisted measures from full-limb radiographs, 100 images (200 limbs) were selected as a random sample from 1,500 full-limb digital radiographs which were part of the Multicenter Osteoarthritis (MOST) Study. Three trained readers used the software program to measure alignment twice from the batch of 100 images, with two or more weeks between batch handling. Manual and computer measures of alignment showed excellent agreement (intraclass correlations [ICCs] 0.977 – 0.999 for computer analysis; 0.820 – 0.995 for manual measures). The computer program applied to full-limb radiographs produced alignment measurements with high inter- and intra-reader reliability (ICCs 0.839 – 0.998). In conclusion, alignment measures using a bone landmark-based approach and a computer program were highly reliable between multiple readers. PMID:19882339

  8. Column Grid Array Rework for High Reliability

    Science.gov (United States)

    Mehta, Atul C.; Bodie, Charles C.

    2008-01-01

    Due to requirements for reduced size and weight, use of grid array packages in space applications has become common place. To meet the requirement of high reliability and high number of I/Os, ceramic column grid array packages (CCGA) were selected for major electronic components used in next MARS Rover mission (specifically high density Field Programmable Gate Arrays). ABSTRACT The probability of removal and replacement of these devices on the actual flight printed wiring board assemblies is deemed to be very high because of last minute discoveries in final test which will dictate changes in the firmware. The questions and challenges presented to the manufacturing organizations engaged in the production of high reliability electronic assemblies are, Is the reliability of the PWBA adversely affected by rework (removal and replacement) of the CGA package? and How many times can we rework the same board without destroying a pad or degrading the lifetime of the assembly? To answer these questions, the most complex printed wiring board assembly used by the project was chosen to be used as the test vehicle, the PWB was modified to provide a daisy chain pattern, and a number of bare PWB s were acquired to this modified design. Non-functional 624 pin CGA packages with internal daisy chained matching the pattern on the PWB were procured. The combination of the modified PWB and the daisy chained packages enables continuity measurements of every soldered contact during subsequent testing and thermal cycling. Several test vehicles boards were assembled, reworked and then thermal cycled to assess the reliability of the solder joints and board material including pads and traces near the CGA. The details of rework process and results of thermal cycling are presented in this paper.

  9. Radiographic measurement reliability of lumbar lordosis in ankylosing spondylitis.

    Science.gov (United States)

    Lee, Jung Sub; Goh, Tae Sik; Park, Shi Hwan; Lee, Hong Seok; Suh, Kuen Tak

    2013-04-01

    Intraobserver and interobserver reliabilities of the several different methods to measure lumbar lordosis have been reported. However, it has not been studied sofar in patients with ankylosing spondylitis (AS). We evaluated the inter and intraobserver reliabilities of six specific measures of global lumbar lordosis in patients with AS. Ninety-one consecutive patients with AS who met the most recently modified New York criteria were enrolled and underwent anteroposterior and lateral radiographs of whole spine. The radiographs were divided into non-ankylosis (no bony bridge in the lumbar spine), incomplete ankylosis (lumbar spines were partially connected by bony bridge) and complete ankylosis groups to evaluate the reliability of the Cobb L1-S1, Cobb L1-L5, centroid, posterior tangent L1-S1, posterior tangent L1-L5, and TRALL methods. The radiographs were composed of 39 non-ankylosis, 27 incomplete ankylosis and 25 complete ankylosis. Intra- and inter-class correlation coefficients (ICCs) of all six methods were generally high. The ICCs were all ≥0.77 (excellent) for the six radiographic methods in the combined group. However, a comparison of the ICCs, 95 % confidence intervals and mean absolute difference (MAD) between groups with varying degrees of ankylosis showed that the reliability of the lordosis measurements decreased in proportion to the severity of ankylosis. The Cobb L1-S1, Cobb L1-L5 and posterior tangent L1-S1 method demonstrated higher ICCs for both inter and intraobserver comparisons and the other methods showed lower ICCs in all groups. The intraobserver MAD was similar in the Cobb L1-S1 and Cobb L1-L5 (2.7°-4.3°), but the other methods showed higher intraobserver MAD. Interobserver MAD of Cobb L1-L5 only showed low in all group. These results are the first to provide a reliability analysis of different global lumbar lordosis measurement methods in AS. The findings in this study demonstrated that the Cobb L1-L5 method is reliable for measuring

  10. Validity and reliability of balance assessment software using the Nintendo Wii balance board: usability and validation.

    Science.gov (United States)

    Park, Dae-Sung; Lee, GyuChang

    2014-06-10

    A balance test provides important information such as the standard to judge an individual's functional recovery or make the prediction of falls. The development of a tool for a balance test that is inexpensive and widely available is needed, especially in clinical settings. The Wii Balance Board (WBB) is designed to test balance, but there is little software used in balance tests, and there are few studies on reliability and validity. Thus, we developed a balance assessment software using the Nintendo Wii Balance Board, investigated its reliability and validity, and compared it with a laboratory-grade force platform. Twenty healthy adults participated in our study. The participants participated in the test for inter-rater reliability, intra-rater reliability, and concurrent validity. The tests were performed with balance assessment software using the Nintendo Wii balance board and a laboratory-grade force platform. Data such as Center of Pressure (COP) path length and COP velocity were acquired from the assessment systems. The inter-rater reliability, the intra-rater reliability, and concurrent validity were analyzed by an intraclass correlation coefficient (ICC) value and a standard error of measurement (SEM). The inter-rater reliability (ICC: 0.89-0.79, SEM in path length: 7.14-1.90, SEM in velocity: 0.74-0.07), intra-rater reliability (ICC: 0.92-0.70, SEM in path length: 7.59-2.04, SEM in velocity: 0.80-0.07), and concurrent validity (ICC: 0.87-0.73, SEM in path length: 5.94-0.32, SEM in velocity: 0.62-0.08) were high in terms of COP path length and COP velocity. The balance assessment software incorporating the Nintendo Wii balance board was used in our study and was found to be a reliable assessment device. In clinical settings, the device can be remarkably inexpensive, portable, and convenient for the balance assessment.

  11. Best estimate probabilistic safety assessment results for the Westinghouse Advanced Loop Tester (WALT)

    International Nuclear Information System (INIS)

    Wang, Guoqiang; Xu, Yiban; Oelrich, Robert L. Jr.; Byers, William A.; Young, Michael Y.; Karoutas, Zeses E.

    2011-01-01

    The nuclear industry uses the probabilistic safety assessment (PSA) technique to improve safety decision making and operation. The methodology evaluates the system reliability, which is defined as the probability of system success, and the postulated accident/problematic scenarios of systems for the nuclear power plants or other facilities. The best estimate probabilistic safety assessment (BE-PSA) method of evaluating system reliability and postulated problematic scenarios will produce more detailed results of interest, such as best estimated reliability analysis and detailed thermal hydraulic calculations using a sub-channel or Computational Fluid Dynamics (CFD) code. The methodology is typically applied to reactors, but can also be applied to any system such as a test facility. In this paper, a BE-PSA method is introduced and used for evaluating the Westinghouse Advanced Loop Tester (WALT). The WALT test loop at the George Westinghouse Science and Technology Center (STC), which was completed in October 2005, is designed to be utilized to model the top grid span of a hot rod in a fuel assembly under the Pressurizer Water Reactor (PWR) normal operating conditions. In order to safely and successfully operate the WALT test loop and correctly use the WALT experimental data, it is beneficial to perform a probabilistic safety assessment and analyze the thermal hydraulic results for the WALT loop in detail. Since October 2005, a number of test runs have been performed on the WALT test facility designed and fabricated by Westinghouse Electric Company LLC. This paper briefly describes the BE-PSA method and performs BE-PSA for the WALT loop. Event trees linked with fault trees embedding thermal hydraulic analysis models, such as sub-channel and/or CFD models, were utilized in the analyses. Consequently, some selected useful experimental data and analysis results are presented for future guidance on WALT and/or other similar test facilities. For example, finding and

  12. Fidedignidade inter e intradias de um teste de potência muscular Inter and intraday reliability of a test of muscle power

    Directory of Open Access Journals (Sweden)

    Roberto Simão

    2001-08-01

    Full Text Available Com o envelhecimento há rápida e relevante perda de potência muscular (PM, prejudicando a autonomia e a qualidade de vida, tornando conveniente avaliar a PM. O objetivo do estudo foi determinar a fidedignidade inter e intradias de um teste simples de PM, realizado em uma carga previamente individualizada. Avaliamos 18 jovens adultos saudáveis, sendo 12 mulheres, inexperientes quanto a exercícios de fortalecimento. Determinou-se inicialmente 1RM com medida simultânea da velocidade e da potência (Fitrodyne, Bratislava, no exercício remada alta, até a altura mesoesternal na posição ortostática, obtendo-se ainda a carga na qual se conseguia a maior PM. Na semana seguinte, por cinco dias consecutivos, eles realizaram em quatro dias 2x2 repetições e em um dia 10x2 repetições (3s de intervalo entre as repetições, o mais rápido possível na fase concêntrica, com a carga de PM. Comparando os resultados pela ANOVA para medidas repetidas e teste de Bonferroni, verificou-se que a PM máxima não diferia - médias entre 262 e 267W (p = 0,69. Para a variabilidade dos dados individuais, encontraram-se valores de 3 e 8%, respectivamente, para o coeficiente de variação (CV e para a média da variação dos resultados pela média dos indivíduos M-m/X. Nas dez séries consecutivas os valores ficaram entre 242 e 263W, somente identificando-se diferenças entre as séries 1 e 4 e 6 (p Aging induces fast and relevant decrements in muscle power (MP, reducing autonomy and quality of life. The authors' aim was to determine reliability data in a new, simple protocol for muscle power using a previously individualized load. The authors evaluated 18 healthy young adults (12 women, unaccustomed to strengthening exercises. Initially, 1-RM was determined with simultaneous measurement of velocity and MP (Fitrodyne, Bratislava in an upright row exercise, performed up to mesosternal level in standing position, and measurement of load in which MP was

  13. Inter-rater agreement on PIVC-associated phlebitis signs, symptoms and scales.

    Science.gov (United States)

    Marsh, Nicole; Mihala, Gabor; Ray-Barruel, Gillian; Webster, Joan; Wallis, Marianne C; Rickard, Claire M

    2015-10-01

    Many peripheral intravenous catheter (PIVC) infusion phlebitis scales and definitions are used internationally, although no existing scale has demonstrated comprehensive reliability and validity. We examined inter-rater agreement between registered nurses on signs, symptoms and scales commonly used in phlebitis assessment. Seven PIVC-associated phlebitis signs/symptoms (pain, tenderness, swelling, erythema, palpable venous cord, purulent discharge and warmth) were observed daily by two raters (a research nurse and registered nurse). These data were modelled into phlebitis scores using 10 different tools. Proportions of agreement (e.g. positive, negative), observed and expected agreements, Cohen's kappa, the maximum achievable kappa, prevalence- and bias-adjusted kappa were calculated. Two hundred ten patients were recruited across three hospitals, with 247 sets of paired observations undertaken. The second rater was blinded to the first's findings. The Catney and Rittenberg scales were the most sensitive (phlebitis in >20% of observations), whereas the Curran, Lanbeck and Rickard scales were the most restrictive (≤2% phlebitis). Only tenderness and the Catney (one of pain, tenderness, erythema or palpable cord) and Rittenberg scales (one of erythema, swelling, tenderness or pain) had acceptable (more than two-thirds, 66.7%) levels of inter-rater agreement. Inter-rater agreement for phlebitis assessment signs/symptoms and scales is low. This likely contributes to the high degree of variability in phlebitis rates in literature. We recommend further research into assessment of infrequent signs/symptoms and the Catney or Rittenberg scales. New approaches to evaluating vein irritation that are valid, reliable and based on their ability to predict complications need exploration. © 2015 John Wiley & Sons, Ltd.

  14. Delivering high performance BWR fuel reliably

    International Nuclear Information System (INIS)

    Schardt, J.F.

    1998-01-01

    Utilities are under intense pressure to reduce their production costs in order to compete in the increasingly deregulated marketplace. They need fuel, which can deliver high performance to meet demanding operating strategies. GE's latest BWR fuel design, GE14, provides that high performance capability. GE's product introduction process assures that this performance will be delivered reliably, with little risk to the utility. (author)

  15. Two-stage Lagrangian modeling of ignition processes in ignition quality tester and constant volume combustion chambers

    KAUST Repository

    Alfazazi, Adamu; Kuti, Olawole Abiola; Naser, Nimal; Chung, Suk-Ho; Sarathy, Mani

    2016-01-01

    The ignition characteristics of isooctane and n-heptane in an ignition quality tester (IQT) were simulated using a two-stage Lagrangian (TSL) model, which is a zero-dimensional (0-D) reactor network method. The TSL model was also used to simulate

  16. Highly reliable electro-hydraulic control system

    International Nuclear Information System (INIS)

    Mande, Morima; Hiyama, Hiroshi; Takahashi, Makoto

    1984-01-01

    The unscheduled shutdown of nuclear power stations disturbs power system, and exerts large influence on power generation cost due to the lowering of capacity ratio; therefore, high reliability is required for the control system of nuclear power stations. Toshiba Corp. has exerted effort to improve the reliability of the control system of power stations, and in this report, the electro-hydraulic control system for the turbines of nuclear power stations is described. The main functions of the electro-hydraulic control system are the control of main steam pressure with steam regulation valves and turbine bypass valves, the control of turbine speed and load, the prevention of turbine overspeed, the protection of turbines and so on. The system is composed of pressure sensors and a speed sensor, the control board containing the electronic circuits for control computation and protective sequence, the oil cylinders, servo valves and opening detectors of the valves for control, a high pressure oil hydraulic machine and piping, the operating panel and so on. The main features are the adoption of tripling intermediate value selection method, the multiplying of protection sensors and the adoption of 2 out of 3 trip logic, the multiplying of power sources, the improvement of the reliability of electronic circuit hardware and oil hydraulic system. (Kako, I.)

  17. Food and beverage environment analysis and monitoring system: a reliability study in the school food and beverage environment.

    Science.gov (United States)

    Bullock, Sally Lawrence; Craypo, Lisa; Clark, Sarah E; Barry, Jason; Samuels, Sarah E

    2010-07-01

    States and school districts around the country are developing policies that set nutrition standards for competitive foods and beverages sold outside of the US Department of Agriculture's reimbursable school lunch program. However, few tools exist for monitoring the implementation of these new policies. The objective of this research was to develop a computerized assessment tool, the Food and Beverage Environment Analysis and Monitoring System (FoodBEAMS), to collect data on the competitive school food environment and to test the inter-rater reliability of the tool among research and nonresearch professionals. FoodBEAMS was used to collect data in spring 2007 on the competitive foods and beverages sold in 21 California high schools. Adherence of the foods and beverages to California's competitive food and beverage nutrition policies for schools (Senate Bills 12 and 965) was determined using the data collected by both research and nonresearch professionals. The inter-rater reliability between the data collectors was assessed using the intraclass correlation coefficient. Researcher vs researcher and researcher vs nonresearcher inter-rater reliability was high for both foods and beverages, with intraclass correlation coefficients ranging from .972 to .987. Results of this study provide evidence that FoodBEAMS is a promising tool for assessing and monitoring adherence to nutrition standards for competitive foods sold on school campuses and can be used reliably by both research and nonresearch professionals. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  18. Delivering high performance BWR fuel reliably

    Energy Technology Data Exchange (ETDEWEB)

    Schardt, J.F. [GE Nuclear Energy, Wilmington, NC (United States)

    1998-07-01

    Utilities are under intense pressure to reduce their production costs in order to compete in the increasingly deregulated marketplace. They need fuel, which can deliver high performance to meet demanding operating strategies. GE's latest BWR fuel design, GE14, provides that high performance capability. GE's product introduction process assures that this performance will be delivered reliably, with little risk to the utility. (author)

  19. Efficient clinical evaluation of guideline quality: development and testing of a new tool

    Science.gov (United States)

    2014-01-01

    Background Evaluating the methodological quality of clinical practice guidelines is essential before deciding which ones which could best inform policy or practice. One current method of evaluating clinical guideline quality is the research-focused AGREE II instrument. This uses 23 questions scored 1–7, arranged in six domains, which requires at least two independent testers, and uses a formulaic weighted domain scoring system. Following feedback from time-poor clinicians, policy-makers and managers that this instrument did not suit clinical need, we developed and tested a simpler, shorter, binary scored instrument (the iCAHE Guideline Quality Checklist) designed for single users. Methods Content and construct validity, inter-tester reliability and clinical utility were tested by comparing the new iCAHE Guideline Quality Checklist with the AGREE II instrument. Firstly the questions and domains in both instruments were compared. Six randomly-selected guidelines on a similar theme were then assessed by three independent testers with different experience in guideline quality assessment, using both instruments. Per guideline, weighted domain and total AGREE II scores were calculated, using the scoring rubric for three testers. Total iCAHE scores were calculated per guideline, per tester. The linear relationship between iCAHE and AGREE II scores was assessed using Pearson r correlation coefficients. Score differences between testers were assessed for the iCAHE Guideline Quality Checklist. Results There were congruent questions in each instrument in four domains (Scope & Purpose, Stakeholder involvement, Underlying evidence/Rigour, Clarity). The iCAHE and AGREE II scores were moderate to strongly correlated for the six guidelines. There was generally good agreement between testers for iCAHE scores, irrespective of their experience. The iCAHE instrument was preferred by all testers, and took significantly less time to administer than the AGREE II instrument. However

  20. Segmental Musculoskeletal Examinations using Dual-Energy X-Ray Absorptiometry (DXA): Positioning and Analysis Considerations.

    Science.gov (United States)

    Hart, Nicolas H; Nimphius, Sophia; Spiteri, Tania; Cochrane, Jodie L; Newton, Robert U

    2015-09-01

    Musculoskeletal examinations provide informative and valuable quantitative insight into muscle and bone health. DXA is one mainstream tool used to accurately and reliably determine body composition components and bone mass characteristics in-vivo. Presently, whole body scan models separate the body into axial and appendicular regions, however there is a need for localised appendicular segmentation models to further examine regions of interest within the upper and lower extremities. Similarly, inconsistencies pertaining to patient positioning exist in the literature which influence measurement precision and analysis outcomes highlighting a need for standardised procedure. This paper provides standardised and reproducible: 1) positioning and analysis procedures using DXA and 2) reliable segmental examinations through descriptive appendicular boundaries. Whole-body scans were performed on forty-six (n = 46) football athletes (age: 22.9 ± 4.3 yrs; height: 1.85 ± 0.07 cm; weight: 87.4 ± 10.3 kg; body fat: 11.4 ± 4.5 %) using DXA. All segments across all scans were analysed three times by the main investigator on three separate days, and by three independent investigators a week following the original analysis. To examine intra-rater and inter-rater, between day and researcher reliability, coefficients of variation (CV) and intraclass correlation coefficients (ICC) were determined. Positioning and segmental analysis procedures presented in this study produced very high, nearly perfect intra-tester (CV ≤ 2.0%; ICC ≥ 0.988) and inter-tester (CV ≤ 2.4%; ICC ≥ 0.980) reliability, demonstrating excellent reproducibility within and between practitioners. Standardised examinations of axial and appendicular segments are necessary. Future studies aiming to quantify and report segmental analyses of the upper- and lower-body musculoskeletal properties using whole-body DXA scans are encouraged to use the patient positioning and image analysis procedures outlined in this

  1. The use and reliability of SymNose for quantitative measurement of the nose and lip in unilateral cleft lip and palate patients.

    Science.gov (United States)

    Mosmuller, David; Tan, Robin; Mulder, Frans; Bachour, Yara; de Vet, Henrica; Don Griot, Peter

    2016-10-01

    It is essential to have a reliable assessment method in order to compare the results of cleft lip and palate surgery. In this study the computer-based program SymNose, a method for quantitative assessment of the nose and lip, will be assessed on usability and reliability. The symmetry of the nose and lip was measured twice in 50 six-year-old complete and incomplete unilateral cleft lip and palate patients by four observers. For the frontal view the asymmetry level of the nose and upper lip were evaluated and for the basal view the asymmetry level of the nose and nostrils were evaluated. A mean inter-observer reliability when tracing each image once or twice was 0.70 and 0.75, respectively. Tracing the photographs with 2 observers and 4 observers gave a mean inter-observer score of 0.86 and 0.92, respectively. The mean intra-observer reliability varied between 0.80 and 0.84. SymNose is a practical and reliable tool for the retrospective assessment of large caseloads of 2D photographs of cleft patients for research purposes. Moderate to high single inter-observer reliability was found. For future research with SymNose reliable outcomes can be achieved by using the average outcomes of single tracings of two observers. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Inter-rater Reliability of the Dysphagia Outcome and Severity Scale (DOSS): Effects of Clinical Experience, Audio-Recording and Training.

    Science.gov (United States)

    Zarkada, Angeliki; Regan, Julie

    2017-10-19

    The Dysphagia Outcome and Severity Scale (DOSS) is widely used to measure dysphagia severity based on videofluoroscopy (VFSS). This study investigated inter-rater reliability (IRR) of the DOSS. It also determined the effect of clinical experience, VFSS audio-recording and training on DOSS IRR. A quantitative prospective research design was used. Seventeen speech and language pathologists (SLPs) were recruited from an acute teaching hospital, Dublin (> 3 years' VFSS experience, n = 10) and from a postgraduate dysphagia programme in a university setting (training session on DOSS rating after which DOSS IRR was re-tested. Cohen's kappa co-efficient was used to establish IRR. IRR of the DOSS presented only fair agreement (κ = 0.36, p training (κ = 0.328) was significantly better comparing to post-training (κ = 0.218) (p < 0.05). Findings raise concerns as the DOSS is frequently used in clinical practice to capture dysphagia severity and to monitor changes.

  3. Novel in situ mechanical testers to enable integrated metal surface micro-machines.

    Energy Technology Data Exchange (ETDEWEB)

    Follstaedt, David Martin; de Boer, Maarten Pieter; Kotula, Paul Gabriel; Hearne, Sean Joseph; Foiles, Stephen Martin; Buchheit, Thomas Edward; Dyck, Christopher William

    2005-10-01

    The ability to integrate metal and semiconductor micro-systems to perform highly complex functions, such as RF-MEMS, will depend on developing freestanding metal structures that offer improved conductivity, reflectivity, and mechanical properties. Three issues have prevented the proliferation of these systems: (1) warpage of active components due to through-thickness stress gradients, (2) limited component lifetimes due to fatigue, and (3) low yield strength. To address these issues, we focus on developing and implementing techniques to enable the direct study of the stress and microstructural evolution during electrodeposition and mechanical loading. The study of stress during electrodeposition of metal thin films is being accomplished by integrating a multi-beam optical stress sensor into an electrodeposition chamber. By coupling the in-situ stress information with ex-situ microstructural analysis, a scientific understanding of the sources of stress during electrodeposition will be obtained. These results are providing a foundation upon which to develop a stress-gradient-free thin film directly applicable to the production of freestanding metal structures. The issues of fatigue and yield strength are being addressed by developing novel surface micromachined tensile and bend testers, by interferometry, and by TEM analysis. The MEMS tensile tester has a ''Bosch'' etched hole to allow for direct viewing of the microstructure in a TEM before, during, and after loading. This approach allows for the quantitative measurements of stress-strain relations while imaging dislocation motion, and determination of fracture nucleation in samples with well-known fatigue/strain histories. This technique facilitates the determination of the limits for classical deformation mechanisms and helps to formulate a new understanding of the mechanical response as the grain sizes are refined to a nanometer scale. Together, these studies will result in a science

  4. Reliability of infrared thermometric measurements of skin temperature in the hand.

    Science.gov (United States)

    Packham, Tara L; Fok, Diana; Frederiksen, Karen; Thabane, Lehana; Buckley, Norman

    2012-01-01

    Clinical measurement study. Skin temperature asymmetries (STAs) are used in the diagnosis of complex regional pain syndrome (CRPS), but little evidence exists for reliability of the equipment and methods. This study examined the reliability of an inexpensive infrared (IR) thermometer and measurement points in the hand for the study of STA. ST was measured three times at five points on both hands with an IR thermometer by two raters in 20 volunteers (12 normals and 8 CRPS). ST measurement results using IR thermometers support inter-rater reliability: intraclass correlation coefficient (ICC) estimate for single measures 0.80; all ST measurement points were also highly reliable (ICC single measures, 0.83-0.91). The equipment demonstrated excellent reliability, with little difference in the reliability of the five measurement sites. These preliminary findings support their use in future CRPS research. Not applicable. Copyright © 2012 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  5. Reliability of the Bulb Dynamometer for Assessing Grip Strength

    Directory of Open Access Journals (Sweden)

    Colleen Maher

    2018-04-01

    Full Text Available Background: Hand function is an overall indicator of health and is often measured using grip strength. Handheld dynamometry is the most common method of measuring grip strength. The purpose of this study was to determine the inter-rater and test-retest reliability, the reliability of one trial versus three trials, and the preliminary norms for a young adult population using the Baseline® Pneumatic Squeeze Bulb Dynamometer (30 psi. Methods: This study used a one-group methodological design. One hundred and three healthy adults (30 males and 73 females were recruited. Six measurements were collected for each hand per participant. The data was analyzed using Intraclass Correlation Coefficients (ICC two-way effects model (2,2 and paired-samples t-tests. Results: The ICC for inter-rater reliability ranged from 0.955 to 0.977. Conclusion: The results of this study suggest that the bulb dynamometer is a reliable tool to measure grip strength and should be further explored for reliable and valid use in diverse populations and as an alternative to the Jamar dynamometer.

  6. A clinical assessment tool used for physiotherapy students--is it reliable?

    Science.gov (United States)

    Lewis, Lucy K; Stiller, Kathy; Hardy, Frances

    2008-01-01

    Educational institutions providing professional programs such as physiotherapy must provide high-quality student assessment procedures. To ensure that assessment is consistent, assessment tools should have an acceptable level of reliability. There is a paucity of research evaluating the reliability of clinical assessment tools used for physiotherapy students. This study evaluated the inter- and intrarater reliability of an assessment tool used for physiotherapy students during a clinical placement. Five clinical educators and one academic participated in the study. Each rater independently marked 22 student written assessments that had been completed by students after viewing a videotaped patient physiotherapy assessment. The raters repeated the marking process 7 weeks later, with the assessments provided in a randomised order. The interrater reliability (Intraclass Correlation Coefficient) for the total scores was 0.32, representing a poor level of reliability. A high level of intrarater reliability (percentage agreement) was found for the clinical educators, with a difference in section scores of one mark or less on 93.4% of occasions. Further research should be undertaken to reevaluate the reliability of this clinical assessment tool following training. The reliability of clinical assessment tools used in other areas of physiotherapy education should be formally measured rather than assumed.

  7. Inter- and intrarater reliability of two proprioception tests using clinical applicable measurement tools in subjects with and without knee osteoarthritis.

    Science.gov (United States)

    Baert, Isabel A C; Lluch, Enrique; Struyf, Thomas; Peeters, Greta; Van Oosterwijck, Sophie; Tuynman, Joanna; Rufai, Salim; Struyf, Filip

    2018-06-01

    The therapeutic value of proprioceptive-based exercises in knee osteoarthritis (KOA) management warrants investigation of proprioceptive testing methods easily accessible in clinical practice. To estimate inter- and intrarater reliability of the knee joint position sense (KJPS) test and knee force sense (KFS) test in subjects with and without KOA. Cross-sectional test-retest design. Two blinded raters performed independently repeated measures of the KJPS and KFS test, using an analogue inclinometer and handheld dynamometer, respectively, in eight KOA patients (12 symptomatic knees) and 26 healthy controls (52 asymptomatic knees). Intraclass correlation coefficients (ICCs; model 2,1), standard error of measurement (SEM) and minimal detectable change with 95% confidence bounds (MDC 95 ) were calculated. For KJPS, results showed good to excellent test-retest agreement (ICCs 0.70-0.95 in KOA patients; ICCs 0.65-0.85 in healthy controls). A 2° measurement error (SEM 1°) was reported when measuring KJPS in multiple test positions and calculating mean repositioning error. Testing KOA patients pre and post therapy a repositioning error larger than 4° (MDC 95 ) is needed to consider true change. Measuring KFS using handheld dynamometry showed poor to fair interrater and poor to excellent intrarater reliability in subjects with and without KOA. Measuring KJPS in multiple test positions using an analogue inclinometer and calculating mean repositioning error is reliable and can be used in clinical practice. We do not recommend the use of the KFS test to clinicians. Further research is required to establish diagnostic accuracy and validity of our KJPS test in larger knee pain populations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Custom high-reliability radiation-hard CMOS-LSI circuit design

    International Nuclear Information System (INIS)

    Barnard, W.J.

    1981-01-01

    Sandia has developed a custom CMOS-LSI design capability to provide high reliability radiation-hardened circuits. This capability relies on (1) proven design practices to enhance reliability, (2) use of well characterized cells and logic modules, (3) computer-aided design tools to reduce design time and errors and to standardize design definition, and (4) close working relationships with the system designer and technology fabrication personnel. Trade-offs are made during the design between circuit complexity/performance and technology/producibility for high reliability and radiation-hardened designs to result. Sandia has developed and is maintaining a radiation-hardened bulk CMOS technology fabrication line for production of prototype and small production volume parts

  9. HitPredict version 4: comprehensive reliability scoring of physical protein?protein interactions from more than 100 species

    OpenAIRE

    L?pez, Yosvany; Nakai, Kenta; Patil, Ashwini

    2015-01-01

    HitPredict is a consolidated resource of experimentally identified, physical protein?protein interactions with confidence scores to indicate their reliability. The study of genes and their inter-relationships using methods such as network and pathway analysis requires high quality protein?protein interaction information. Extracting reliable interactions from most of the existing databases is challenging because they either contain only a subset of the available interactions, or a mixture of p...

  10. Reliability and criterion validity of an observation protocol for working technique assessments in cash register work.

    Science.gov (United States)

    Palm, Peter; Josephson, Malin; Mathiassen, Svend Erik; Kjellberg, Katarina

    2016-06-01

    We evaluated the intra- and inter-observer reliability and criterion validity of an observation protocol, developed in an iterative process involving practicing ergonomists, for assessment of working technique during cash register work for the purpose of preventing upper extremity symptoms. Two ergonomists independently assessed 17 15-min videos of cash register work on two occasions each, as a basis for examining reliability. Criterion validity was assessed by comparing these assessments with meticulous video-based analyses by researchers. Intra-observer reliability was acceptable (i.e. proportional agreement >0.7 and kappa >0.4) for 10/10 questions. Inter-observer reliability was acceptable for only 3/10 questions. An acceptable inter-observer reliability combined with an acceptable criterion validity was obtained only for one working technique aspect, 'Quality of movements'. Thus, major elements of the cashiers' working technique could not be assessed with an acceptable accuracy from short periods of observations by one observer, such as often desired by practitioners. Practitioner Summary: We examined an observation protocol for assessing working technique in cash register work. It was feasible in use, but inter-observer reliability and criterion validity were generally not acceptable when working technique aspects were assessed from short periods of work. We recommend the protocol to be used for educational purposes only.

  11. High Reliability Oscillators for Terahertz Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — To develop reliable THz sources with high power and high DC-RF efficiency, Virginia Diodes, Inc. will develop a thorough understanding of the complex interactions...

  12. Rater reliability and concurrent validity of the Keyboard Personal Computer Style instrument (K-PeCS).

    Science.gov (United States)

    Baker, Nancy A; Cook, James R; Redfern, Mark S

    2009-01-01

    This paper describes the inter-rater and intra-rater reliability, and the concurrent validity of an observational instrument, the Keyboard Personal Computer Style instrument (K-PeCS), which assesses stereotypical postures and movements associated with computer keyboard use. Three trained raters independently rated the video clips of 45 computer keyboard users to ascertain inter-rater reliability, and then re-rated a sub-sample of 15 video clips to ascertain intra-rater reliability. Concurrent validity was assessed by comparing the ratings obtained using the K-PeCS to scores developed from a 3D motion analysis system. The overall K-PeCS had excellent reliability [inter-rater: intra-class correlation coefficients (ICC)=.90; intra-rater: ICC=.92]. Most individual items on the K-PeCS had from good to excellent reliability, although six items fell below ICC=.75. Those K-PeCS items that were assessed for concurrent validity compared favorably to the motion analysis data for all but two items. These results suggest that most items on the K-PeCS can be used to reliably document computer keyboarding style.

  13. The reliability of WorkWell Systems Functional Capacity Evaluation: a systematic review

    Science.gov (United States)

    2014-01-01

    Background Functional capacity evaluation (FCE) determines a person’s ability to perform work-related tasks and is a major component of the rehabilitation process. The WorkWell Systems (WWS) FCE (formerly known as Isernhagen Work Systems FCE) is currently the most commonly used FCE tool in German rehabilitation centres. Our systematic review investigated the inter-rater, intra-rater and test-retest reliability of the WWS FCE. Methods We performed a systematic literature search of studies on the reliability of the WWS FCE and extracted item-specific measures of inter-rater, intra-rater and test-retest reliability from the identified studies. Intraclass correlation coefficients ≥ 0.75, percentages of agreement ≥ 80%, and kappa coefficients ≥ 0.60 were categorised as acceptable, otherwise they were considered non-acceptable. The extracted values were summarised for the five performance categories of the WWS FCE, and the results were classified as either consistent or inconsistent. Results From 11 identified studies, 150 item-specific reliability measures were extracted. 89% of the extracted inter-rater reliability measures, all of the intra-rater reliability measures and 96% of the test-retest reliability measures of the weight handling and strength tests had an acceptable level of reliability, compared to only 67% of the test-retest reliability measures of the posture/mobility tests and 56% of the test-retest reliability measures of the locomotion tests. Both of the extracted test-retest reliability measures of the balance test were acceptable. Conclusions Weight handling and strength tests were found to have consistently acceptable reliability. Further research is needed to explore the reliability of the other tests as inconsistent findings or a lack of data prevented definitive conclusions. PMID:24674029

  14. Assessment of microelectronics packaging for high temperature, high reliability applications

    Energy Technology Data Exchange (ETDEWEB)

    Uribe, F.

    1997-04-01

    This report details characterization and development activities in electronic packaging for high temperature applications. This project was conducted through a Department of Energy sponsored Cooperative Research and Development Agreement between Sandia National Laboratories and General Motors. Even though the target application of this collaborative effort is an automotive electronic throttle control system which would be located in the engine compartment, results of this work are directly applicable to Sandia`s national security mission. The component count associated with the throttle control dictates the use of high density packaging not offered by conventional surface mount. An enabling packaging technology was selected and thermal models defined which characterized the thermal and mechanical response of the throttle control module. These models were used to optimize thick film multichip module design, characterize the thermal signatures of the electronic components inside the module, and to determine the temperature field and resulting thermal stresses under conditions that may be encountered during the operational life of the throttle control module. Because the need to use unpackaged devices limits the level of testing that can be performed either at the wafer level or as individual dice, an approach to assure a high level of reliability of the unpackaged components was formulated. Component assembly and interconnect technologies were also evaluated and characterized for high temperature applications. Electrical, mechanical and chemical characterizations of enabling die and component attach technologies were performed. Additionally, studies were conducted to assess the performance and reliability of gold and aluminum wire bonding to thick film conductor inks. Kinetic models were developed and validated to estimate wire bond reliability.

  15. Analysis of fatigue reliability for high temperature and high pressure multi-stage decompression control valve

    Science.gov (United States)

    Yu, Long; Xu, Juanjuan; Zhang, Lifang; Xu, Xiaogang

    2018-03-01

    Based on stress-strength interference theory to establish the reliability mathematical model for high temperature and high pressure multi-stage decompression control valve (HMDCV), and introduced to the temperature correction coefficient for revising material fatigue limit at high temperature. Reliability of key dangerous components and fatigue sensitivity curve of each component are calculated and analyzed by the means, which are analyzed the fatigue life of control valve and combined with reliability theory of control valve model. The impact proportion of each component on the control valve system fatigue failure was obtained. The results is shown that temperature correction factor makes the theoretical calculations of reliability more accurate, prediction life expectancy of main pressure parts accords with the technical requirements, and valve body and the sleeve have obvious influence on control system reliability, the stress concentration in key part of control valve can be reduced in the design process by improving structure.

  16. Validity and Reliability of the Clinical Competency Evaluation Instrument for Use among Physiotherapy Students: Pilot study.

    Science.gov (United States)

    Muhamad, Zailani; Ramli, Ayiesah; Amat, Salleh

    2015-05-01

    The aim of this study was to determine the content validity, internal consistency, test-retest reliability and inter-rater reliability of the Clinical Competency Evaluation Instrument (CCEVI) in assessing the clinical performance of physiotherapy students. This study was carried out between June and September 2013 at University Kebangsaan Malaysia (UKM), Kuala Lumpur, Malaysia. A panel of 10 experts were identified to establish content validity by evaluating and rating each of the items used in the CCEVI with regards to their relevance in measuring students' clinical competency. A total of 50 UKM undergraduate physiotherapy students were assessed throughout their clinical placement to determine the construct validity of these items. The instrument's reliability was determined through a cross-sectional study involving a clinical performance assessment of 14 final-year undergraduate physiotherapy students. The content validity index of the entire CCEVI was 0.91, while the proportion of agreement on the content validity indices ranged from 0.83-1.00. The CCEVI construct validity was established with factor loading of ≥0.6, while internal consistency (Cronbach's alpha) overall was 0.97. Test-retest reliability of the CCEVI was confirmed with a Pearson's correlation range of 0.91-0.97 and an intraclass coefficient correlation range of 0.95-0.98. Inter-rater reliability of the CCEVI domains ranged from 0.59 to 0.97 on initial and subsequent assessments. This pilot study confirmed the content validity of the CCEVI. It showed high internal consistency, thereby providing evidence that the CCEVI has moderate to excellent inter-rater reliability. However, additional refinement in the wording of the CCEVI items, particularly in the domains of safety and documentation, is recommended to further improve the validity and reliability of the instrument.

  17. Long-term reliability of the visual EEG Poffenberger paradigm.

    Science.gov (United States)

    Friedrich, Patrick; Ocklenburg, Sebastian; Mochalski, Lisa; Schlüter, Caroline; Güntürkün, Onur; Genc, Erhan

    2017-07-14

    The Poffenberger paradigm is a simple perception task that is used to estimate the speed of information transfer between the two hemispheres, the so-called interhemispheric transfer time (IHTT). Although the original paradigm is a behavioral task, it can be combined with electroencephalography (EEG) to assess the underlying neurophysiological processes during task execution. While older studies have supported the validity of both paradigms for investigating interhemispheric interactions, their long-term reliability has not been assessed systematically before. The present study aims to fill this gap by determining both internal consistency and long-term test-retest reliability of IHTTs produced by using the two different versions of the Poffenberger paradigm in a sample of 26 healthy subjects. The results show high reliability for the EEG Poffenberger paradigm. In contrast, reliability measures for the behavioral Poffenberger paradigm were low. Hence, our results indicate that electrophysiological measures of interhemispheric transfer are more reliable than behavioral measures; the later should be used with caution in research investigating inter-individual differences of neurocognitive measures. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Reliability and validity of CODA motion analysis system for measuring cervical range of motion in patients with cervical spondylosis and anterior cervical fusion.

    Science.gov (United States)

    Gao, Zhongyang; Song, Hui; Ren, Fenggang; Li, Yuhuan; Wang, Dong; He, Xijing

    2017-12-01

    The aim of the present study was to evaluate the reliability of the Cartesian Optoelectronic Dynamic Anthropometer (CODA) motion system in measuring the cervical range of motion (ROM) and verify the construct validity of the CODA motion system. A total of 26 patients with cervical spondylosis and 22 patients with anterior cervical fusion were enrolled and the CODA motion analysis system was used to measure the three-dimensional cervical ROM. Intra- and inter-rater reliability was assessed by interclass correlation coefficients (ICCs), standard error of measurement (SEm), Limits of Agreements (LOA) and minimal detectable change (MDC). Independent samples t-tests were performed to examine the differences of cervical ROM between cervical spondylosis and anterior cervical fusion patients. The results revealed that in the cervical spondylosis group, the reliability was almost perfect (intra-rater reliability: ICC, 0.87-0.95; LOA, -12.86-13.70; SEm, 2.97-4.58; inter-rater reliability: ICC, 0.84-0.95; LOA, -13.09-13.48; SEm, 3.13-4.32). In the anterior cervical fusion group, the reliability was high (intra-rater reliability: ICC, 0.88-0.97; LOA, -10.65-11.08; SEm, 2.10-3.77; inter-rater reliability: ICC, 0.86-0.96; LOA, -10.91-13.66; SEm, 2.20-4.45). The cervical ROM in the cervical spondylosis group was significantly higher than that in the anterior cervical fusion group in all directions except for left rotation. In conclusion, the CODA motion analysis system is highly reliable in measuring cervical ROM and the construct validity was verified, as the system was sufficiently sensitive to distinguish between the cervical spondylosis and anterior cervical fusion groups based on their ROM.

  19. Interference of apex locator, pulp tester and diathermy on pacemaker function.

    Science.gov (United States)

    Sriman, Narayanan; Prabhakar, V; Bhuvaneswaran, J S; Subha, N

    2015-01-01

    The purpose of this study was to evaluate the effects of three electronic apex locators (EAL), electric pulp tester (EPT) and diathermy on pacemaker function in vitro. Three EALs: Root ZX (J. Morita Co., Tustin, CA, U.S.A.), Propex (Dentsply), Mini Apex locator (SybronEndo, Anaheim, CA, USA), EPT (Parkell pulp vitality tester Farmingdale, NY, USA) and Diathermy (Neomed 250 B) were tested for any interference with one pacemaker (A medtronic kappa KVDD901-serial number: PLE734632S). Directly connecting the pacemaker lead with the EAL/EPT/diathermy operating on a flat bench top, the telemetry wand was held directly over the pacemaker to monitor the pacing pattern for a period of 30 s. Pacemaker activity was continuously recorded on the telemetric programmer and electro gram (EGM) readings examined for pacer inhibition, noise reversion or inappropriate pacemaker pulses. All the three apex locators showed no pacing interference or background noise during its function or at rest. The EGM readings of EPT showed varying levels of background noise in between pacing however, this did not affect the normal pacing pattern and the pacing interval remained constant. EGM readings of diathermy showed an increase in the pacing interval (irregular pacing pattern) followed by complete inhibition of the pacing system. The tested EALs do not interfere with cardiac pacemaker function. The tested EPT showed varying levels of background noise but does not interfere with cardiac pacemaker function. Use of Diathermy interfered with the normal pacing, leading to complete inhibition of the pacing system.

  20. High inter-specimen variability of baseline data for the tibio-talar contact area.

    Science.gov (United States)

    Matricali, Giovanni A; Bartels, Ward; Labey, Luc; Dereymaeker, Greta Ph E; Luyten, Frank P; Vander Sloten, Jos

    2009-01-01

    The tibio-talar contact area has been widely investigated to monitor biomechanical changes due to articular incongruities or an altered loading. This study aims to investigate for the first time in a systematic way the extent of the inter-specimen variability of the tibio-talar contact area, and its repercussions when analyzing data concerning this parameter. Ten specimens were loaded to record the tibio-talar contact characteristics by use of pressure sensitive film. The size of the talar dome area, the size of the (normalized) tibio-talar contact area, the position of the tibio-talar contact area, and the shape of the latter were determined and analyzed. Inter-specimen variability was expressed as the coefficient of variation and was calculated for the datasets of previous studies as well. The size of the tibio-talar contact area showed a very high inter-specimen variability, as is the case in previous studies. This high variability persisted when a normalized tibio-talar contact area was calculated. The shape of the tibio-talar contact area showed some basic characteristics, but a high variation in details could be observed. Every specimen can be considered to have its own "ankle print". By this variability, articular incongruities are expected to have a different effect on local biomechanical characteristics in every single individual. Therefore, every single case has to be evaluated and reported for significant changes. In case of modeling, this also underscores the need to use subject specific models fed by sets of parameters derived from a series of single specimens.

  1. High reliability low jitter 80 kV pulse generator

    International Nuclear Information System (INIS)

    Savage, Mark Edward; Stoltzfus, Brian Scott

    2009-01-01

    Switching can be considered to be the essence of pulsed power. Time accurate switch/trigger systems with low inductance are useful in many applications. This article describes a unique switch geometry coupled with a low-inductance capacitive energy store. The system provides a fast-rising high voltage pulse into a low impedance load. It can be challenging to generate high voltage (more than 50 kilovolts) into impedances less than 10 (Omega), from a low voltage control signal with a fast rise time and high temporal accuracy. The required power amplification is large, and is usually accomplished with multiple stages. The multiple stages can adversely affect the temporal accuracy and the reliability of the system. In the present application, a highly reliable and low jitter trigger generator was required for the Z pulsed-power facility [M. E. Savage, L. F. Bennett, D. E. Bliss, W. T. Clark, R. S. Coats,J. M. Elizondo, K. R. LeChien, H. C. Harjes, J. M. Lehr, J. E. Maenchen, D. H. McDaniel, M. F. Pasik, T. D. Pointon, A. C. Owen, D. B. Seidel, D. L. Smith, B. S. Stoltzfus, K.W. Struve, W.A. Stygar, L.K. Warne, and J. R. Woodworth, 2007 IEEE Pulsed Power Conference, Albuquerque, NM (IEEE, Piscataway, NJ, 2007), p. 979]. The large investment in each Z experiment demands low prefire probability and low jitter simultaneously. The system described here is based on a 100 kV DC-charged high-pressure spark gap, triggered with an ultraviolet laser. The system uses a single optical path for simultaneously triggering two parallel switches, allowing lower inductance and electrode erosion with a simple optical system. Performance of the system includes 6 ns output rise time into 5.6 (Omega), 550 ps one-sigma jitter measured from the 5 V trigger to the high voltage output, and misfire probability less than 10 -4 . The design of the system and some key measurements will be shown in the paper. We will discuss the design goals related to high reliability and low jitter. While

  2. Reliability of a four-column classification for tibial plateau fractures.

    Science.gov (United States)

    Martínez-Rondanelli, Alfredo; Escobar-González, Sara Sofía; Henao-Alzate, Alejandro; Martínez-Cano, Juan Pablo

    2017-09-01

    A four-column classification system offers a different way of evaluating tibial plateau fractures. The aim of this study is to compare the intra-observer and inter-observer reliability between four-column and classic classifications. This is a reliability study, which included patients presenting with tibial plateau fractures between January 2013 and September 2015 in a level-1 trauma centre. Four orthopaedic surgeons blindly classified each fracture according to four different classifications: AO, Schatzker, Duparc and four-column. Kappa, intra-observer and inter-observer concordance were calculated for the reliability analysis. Forty-nine patients were included. The mean age was 39 ± 14.2 years, with no gender predominance (men: 51%; women: 49%), and 67% of the fractures included at least one of the posterior columns. The intra-observer and inter-observer concordance were calculated for each classification: four-column (84%/79%), Schatzker (60%/71%), AO (50%/59%) and Duparc (48%/58%), with a statistically significant difference among them (p = 0.001/p = 0.003). Kappa coefficient for intr-aobserver and inter-observer evaluations: Schatzker 0.48/0.39, four-column 0.61/0.34, Duparc 0.37/0.23, and AO 0.34/0.11. The proposed four-column classification showed the highest intra and inter-observer agreement. When taking into account the agreement that occurs by chance, Schatzker classification showed the highest inter-observer kappa, but again the four-column had the highest intra-observer kappa value. The proposed classification is a more inclusive classification for the posteromedial and posterolateral fractures. We suggest, therefore, that it be used in addition to one of the classic classifications in order to better understand the fracture pattern, as it allows more attention to be paid to the posterior columns, it improves the surgical planning and allows the surgical approach to be chosen more accurately.

  3. Memorial Hermann: high reliability from board to bedside.

    Science.gov (United States)

    Shabot, M Michael; Monroe, Douglas; Inurria, Juan; Garbade, Debbi; France, Anne-Claire

    2013-06-01

    In 2006 the Memorial Hermann Health System (MHHS), which includes 12 hospitals, began applying principles embraced by high reliability organizations (HROs). Three factors support its HRO journey: (1) aligned organizational structure with transparent management systems and compressed reporting processes; (2) Robust Process Improvement (RPI) with high-reliability interventions; and (3) cultural establishment, sustainment, and evolution. The Quality and Safety strategic plan contains three domains, each with a specific set of measures that provide goals for performance: (1) "Clinical Excellence;" (2) "Do No Harm;" and (3) "Saving Lives," as measured by the Serious Safety Event rate. MHHS uses a uniform approach to performance improvement--RPI, which includes Six Sigma, Lean, and change management, to solve difficult safety and quality problems. The 9 acute care hospitals provide multiple opportunities to integrate high-reliability interventions and best practices across MHHS. For example, MHHS partnered with the Joint Commission Center for Transforming Healthcare in its inaugural project to establish reliable hand hygiene behaviors, which improved MHHS's average hand hygiene compliance rate from 44% to 92% currently. Soon after compliance exceeded 85% at all 12 hospitals, the average rate of central line-associated bloodstream and ventilator-associated pneumonias decreased to essentially zero. MHHS's size and diversity require a disciplined approach to performance improvement and systemwide achievement of measurable success. The most significant cultural change at MHHS has been the expectation for 100% compliance with evidence-based quality measures and 0% incidence of patient harm.

  4. A new kind high-reliability digital reactivity meter

    International Nuclear Information System (INIS)

    Shen Feng; Jiang Zongbing

    2001-01-01

    The paper introduces a new kind of high-reliability Digital Reactivity Meter developed by the DRM developing group in designing department of Nuclear Power Institute of China. The meter has two independent measure channels, which can be set as either master-slave structure or working independently. This structure will ensure that the meter can continually fulfill its online measure task under the condition of single failure with it. It provides a solution for the conflict between nuclear station's extreme demand in DRM's reliability and instability of computer's business software platform. The instrument reaches both advance and reliability by covering a lot of kinds of complex functions in data process and display

  5. Systems and technologies for high-speed inter-office/datacenter interface

    Science.gov (United States)

    Sone, Y.; Nishizawa, H.; Yamamoto, S.; Fukutoku, M.; Yoshimatsu, T.

    2017-01-01

    Emerging requirements for inter-office/inter-datacenter short reach links for data center interconnects (DCI) and metro transport networks have led to various inter-office and inter-datacenter optical interface technologies. These technologies are bringing significant changes to systems and network architectures. In this paper, we present a system and ZR optical interface technologies for DCI and metro transport networks, then introduce the latest challenges facing the system framework. There are two trends in reach extension; one is to use Ethernet and the other is to use digital coherent technologies. The first approach achieves reach extension while using as many existing Ethernet components as possible. It offers low costs as reuses the cost-effective components created for the large Ethernet market. The second approach adopts low-cost and low power coherent DSPs that implement the minimal set long haul transmission functions. This paper introduces an architecture that integrates both trends. The architecture satisfies both datacom and telecom needs with a common control and management interface and automated configuration.

  6. Inter-individual Differences in Heart Rate Variability Are Associated with Inter-individual Differences in Empathy and Alexithymia

    Directory of Open Access Journals (Sweden)

    Alexander Lischke

    2018-02-01

    Full Text Available In the present study, we investigated whether inter-individual differences in vagally mediated heart rate variability (vmHRV would be associated with inter-individual differences in empathy and alexithymia. To this end, we determined resting state HF-HRV in 90 individuals that also completed questionnaires assessing inter-individual differences in empathy and alexithymia. Our categorical and dimensional analyses revealed that inter-individual differences in HF-HRV were differently associated with inter-individual differences in empathy and alexithymia. We found that individuals with high HF-HRV reported more empathy and less alexithymia than individuals with low HF-HRV. Moreover, we even found that an increase in HF-HRV was associated with an increase in empathy and a decrease in alexithymia across all participants. Taken together, these findings indicate that individuals with high HF-HRV are more empathetic and less alexithymic than individuals with low HF-HRV. These differences in empathy and alexithymia may explain why individuals with high HF-HRV are more successful in sharing and understanding the mental and emotional states of others than individuals with low HF-HRV.

  7. Prophage induction, mutagenesis, and cell survival of Ames' mutagen tester strains after 8-methoxypsoralen plus ultraviolet light-A

    Energy Technology Data Exchange (ETDEWEB)

    Wheeler, L.A.; DeMeo, M. (California Univ., Los Angeles (USA)); Lowe, N. (Combined UCLA-WADSWORTH Dermatology Program, Los Angeles, CA (USA))

    1983-10-01

    8-methoxypsoralen (8-MOP) is not detected as a mutagen in the standard Ames test either in the presence or absence of S9-mix and/or ultraviolet light-A (320-400 nm). The Ames strains have been shown to harbor bacteriophages that are inducible by carcinogens and mutagens. Psoralen plus UVA (PUVA) was found to be a potent prophage inducing treatment. Induction was observed in TA1535, TA1538, TA98, TA100, TA1978 and TA1975 with 8-MOP and UVA. PUVA is a potent bactericidal treatment at concentrations of 8-MOP above 0.5 ..mu..g/ml and 2.5 kJ/m/sup 2/ in tester strains TA1535, TA1538, TA98 and TA100. PUVA is known to be bactericidal, but the cytotoxicity observed in the present study was unique in that the frameshift tester strains (TA1538 and TA98) were more sensitive to the lethal effects of PUVA than the base pair tester strains (TA1535 and TA100). The differential cytotoxicity in such closely related strains led to the examination of some of the strains from which the Ames strains were derived. It is postulated that TA1535 retains a DNA repair function that is lost by TA1538 during the selection for uvrB deficient strains.

  8. Reliability of capturing foot parameters using digital scanning and the neutral suspension casting technique

    Science.gov (United States)

    2011-01-01

    Background A clinical study was conducted to determine the intra and inter-rater reliability of digital scanning and the neutral suspension casting technique to measure six foot parameters. The neutral suspension casting technique is a commonly utilised method for obtaining a negative impression of the foot prior to orthotic fabrication. Digital scanning offers an alternative to the traditional plaster of Paris techniques. Methods Twenty one healthy participants volunteered to take part in the study. Six casts and six digital scans were obtained from each participant by two raters of differing clinical experience. The foot parameters chosen for investigation were cast length (mm), forefoot width (mm), rearfoot width (mm), medial arch height (mm), lateral arch height (mm) and forefoot to rearfoot alignment (degrees). Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI) were calculated to determine the intra and inter-rater reliability. Measurement error was assessed through the calculation of the standard error of the measurement (SEM) and smallest real difference (SRD). Results ICC values for all foot parameters using digital scanning ranged between 0.81-0.99 for both intra and inter-rater reliability. For neutral suspension casting technique inter-rater reliability values ranged from 0.57-0.99 and intra-rater reliability values ranging from 0.36-0.99 for rater 1 and 0.49-0.99 for rater 2. Conclusions The findings of this study indicate that digital scanning is a reliable technique, irrespective of clinical experience, with reduced measurement variability in all foot parameters investigated when compared to neutral suspension casting. PMID:21375757

  9. Reliability and validity of the de Morton Mobility Index in individuals with sub-acute stroke.

    Science.gov (United States)

    Braun, Tobias; Marks, Detlef; Thiel, Christian; Grüneberg, Christian

    2018-02-04

    To establish the validity and reliability of the de Morton Mobility Index (DEMMI) in patients with sub-acute stroke. This cross-sectional study was performed in a neurological rehabilitation hospital. We assessed unidimensionality, construct validity, internal consistency reliability, inter-rater reliability, minimal detectable change and possible floor and ceiling effects of the DEMMI in adult patients with sub-acute stroke. The study included a total sample of 121 patients with sub-acute stroke. We analysed validity (n = 109) and reliability (n = 51) in two sub-samples. Rasch analysis indicated unidimensionality with an overall fit to the model (chi-square = 12.37, p = 0.577). All hypotheses on construct validity were confirmed. Internal consistency reliability (Cronbach's alpha = 0.94) and inter-rater reliability (intraclass correlation coefficient = 0.95; 95% confidence interval: 0.92-0.97) were excellent. The minimal detectable change with 90% confidence was 13 points. No floor or ceiling effects were evident. These results indicate unidimensionality, sufficient internal consistency reliability, inter-rater reliability, and construct validity of the DEMMI in patients with a sub-acute stroke. Advantages of the DEMMI in clinical application are the short administration time, no need for special equipment and interval level data. The de Morton Mobility Index, therefore, may be a useful performance-based bedside test to measure mobility in individuals with a sub-acute stroke across the whole mobility spectrum. Implications for Rehabilitation The de Morton Mobility Index (DEMMI) is an unidimensional measurement instrument of mobility in individuals with sub-acute stroke. The DEMMI has excellent internal consistency and inter-rater reliability, and sufficient construct validity. The minimal detectable change of the DEMMI with 90% confidence in stroke rehabilitation is 13 points. The lack of any floor or ceiling effects on hospital admission indicates

  10. Design and analysis of a toroidal tester for the measurement of core losses under axial compressive stress

    Energy Technology Data Exchange (ETDEWEB)

    Alatawneh, Natheer, E-mail: natheer80@yahoo.com [Department of Mining and Materials Engineering, McGill University, QC H3A 0G4 (Canada); Rahman, Tanvir; Lowther, David A. [Department of Electrical and Computer Engineering, McGill University, QC H3A 0E9 (Canada); Chromik, Richard [Department of Mining and Materials Engineering, McGill University, QC H3A 0G4 (Canada)

    2017-06-15

    Highlights: • Develop a toroidal tester for magnetic measurements under compressive axial stress. • The shape of the toroidal ring has been verified using 3D stress analysis. • The developed design has been prototyped, and measurements were carried out. • Physical explanations for the core loss trend due to stress are provided. - Abstract: Electric machine cores are subjected to mechanical stresses due to manufacturing processes. These stresses include radial, circumferential and axial components that may have significant influences on the magnetic properties of the electrical steel and hence, on the output and efficiencies of electrical machines. Previously, most studies of iron losses due to mechanical stress have considered only radial and circumferential components. In this work, an improved toroidal tester has been designed and developed to measure the core losses and the magnetic properties of electrical steel under a compressive axial stress. The shape of the toroidal ring has been verified using 3D stress analysis. Also, 3D electromagnetic simulations show a uniform flux density distribution in the specimen with a variation of 0.03 T and a maximum average induction level of 1.5 T. The developed design has been prototyped, and measurements were carried out using a steel sample of grade 35WW300. Measurements show that applying small mechanical stresses normal to the sample thickness rises the delivered core losses, then the losses decrease continuously as the stress increases. However, the drop in core losses at high stresses does not go lower than the free-stress condition. Physical explanations for the observed trend of core losses as a function of stress are provided based on core loss separation to the hysteresis and eddy current loss components. The experimental results show that the effect of axial compressive stress on magnetic properties of electrical steel at high level of inductions becomes less pronounced.

  11. A study of the reliability of the Nociception Coma Scale.

    Science.gov (United States)

    Riganello, F; Cortese, M D; Arcuri, F; Candelieri, A; Guglielmino, F; Dolce, G; Sannita, W G; Schnakers, C

    2015-04-01

    In this study, we investigated the reliability of the Nociception Coma Scale which has recently been developed to assess nociception in non-communicative, severely brain-injured patients. Prospective cross-sequential study. Semi-intensive care unit and long-term brain injury care. Forty-four patients diagnosed as being in a vegetative state (n=26) or in a minimally conscious state (n=18). Patients were assessed by two experts (rater A and rater B) on two consecutive weeks to measure inter-rater agreement and test-retest reliability. Total scores and subscores of the Nociception Coma Scale. We performed a total of 176 assessments. The inter-rater agreement was moderate for the total scores (k = 0.57) and fair to substantial for the subscores (0.33 ≤ k ≤ 0.62) on week 2. The test-retest reliability was substantial for the total scores (k = 0.66) and moderate to almost perfect for the subscores (0.53 ≤ k ≤ 0.96) for rater A. The inter-rater agreement was weaker on week 1, whereas the test-retest reliability was lower for the least experienced rater (rater B). This study provides further evidence of the psychometric qualities of the Nociception Coma Scale. Future studies should assess the impact of practical experience and background on administration and scoring of the scale. © The Author(s) 2014.

  12. A portable fracture toughness tester for biological materials

    Science.gov (United States)

    Darvell, B. W.; Lee, P. K. D.; Yuen, T. D. B.; Lucas, P. W.

    1996-06-01

    A portable mechanical tester is described which is both lightweight and cheap to produce. The machine is simple and convenient to operate and requires only a minimum of personnel training. It can be used to measure the fundamental mechanical properties of pliant solids, particularly toughness (in the sense of `work of fracture') using either scissors or wedge tests. This is achieved through a novel hardware integration technique. The circuits are described. The use of the machine does not require a chart recorder but it can be linked to a personal computer, either to show force - displacement relationships or for data storage. The design allows the use of any relatively `soft' mechanical test, i.e. tests in which the deformability of the frame of the machine and its load cell do not introduce significant errors into the results. Examples of its use in measuring the toughness of biomaterials by scissors (paper, wood) and wedges (mung bean starch gels) are given.

  13. The reliability, validity, and applicability of an English language version of the Mini-ICF-APP.

    Science.gov (United States)

    Molodynski, Andrew; Linden, Michael; Juckel, George; Yeeles, Ksenija; Anderson, Catriona; Vazquez-Montes, Maria; Burns, Tom

    2013-08-01

    This study aimed at establishing the validity and reliability of an English language version of the Mini-ICF-APP. One hundred and five patients under the care of secondary mental health care services were assessed using the Mini-ICF-APP and several well-established measures of functioning and symptom severity. 47 (45 %) patients were interviewed on two occasions to ascertain test-retest reliability and 50 (48 %) were interviewed by two researchers simultaneously to determine the instrument's inter-rater reliability. Occupational and sick leave status were also recorded to assess construct validity. The Mini-ICF-APP was found to have substantial internal consistency (Chronbach's α 0.869-0.912) and all 13 items correlated highly with the total score. Analysis also showed that the Mini-ICF-APP had good test-retest (ICC 0.832) and inter-rater (ICC 0.886) reliability. No statistically significant association with length of sick leave was found, but the unemployed scored higher on the Mini ICF-APP than those in employment (mean 18.4, SD 9.1 vs. 9.4, SD 6.4, p Mini-ICF-APP correlated highly with the other measures of illness severity and functioning considered in the study. The English version of the Mini-ICF-APP is a reliable and valid measure of disorders of capacity as defined by the International Classification of Functioning. Further work is necessary to establish whether the scale could be divided into sub scales which would allow the instrument to more sensitively measure an individual's specific impairments.

  14. Validity and repeatability of goniometry in normal horses.

    Science.gov (United States)

    Adair, Henry S; Marcellin-Little, Denis J; Levine, David

    2016-07-19

    To assess validity and inter- and intra-tester reliability of equine goniometry and to establish values for carpal, metacarpophalangeal, tarsal, and metatarsophalangeal flexion and extension in horses. Seventeen healthy equine subjects of varied breeds were used. Three investigators blindly and independently measured in triplicate the extension and flexion of carpal, metacarpophalangeal, tarsal, and metatarsophalangeal joints of 17 horses after sedation. Radiographs of these joints in flexion and extension were acquired while under sedation. Goniometric and radiographic measurements were compared statistically and were correlated. A Bland-Altman plot was constructed. Inter- and intra-tester repeatability of goniometry were evaluated by calculating intraclass correlation coefficients (ICC). Mean flexion and extension of carpal, metacarpophalangeal, tarsal, and metatarsophalangeal joints were calculated. Goniometric and radiographic measurements did not differ statistically and were significantly correlated (correlation coefficients ranged from 0.59 - 0.89). The mean difference between goniometric and radiographic measurements was 0.4°. Triplicate measurements collected by the three raters did not differ significantly within raters (ICC ranging from 0.950 - 0.995) and between raters (ICC ranging from 0.942 - 0.989). Goniometry is a valid and repeatable tool for evaluation of the range of motion of carpal, metacarpophalangeal, tarsal, and metatarsophalangeal joints in standing, sedated healthy horses.

  15. Examiner Reliability of Fluorosis Scoring: A Comparison of Photographic and Clinical Examination Findings

    Science.gov (United States)

    Cruz-Orcutt, Noemi; Warren, John J.; Broffitt, Barbara; Levy, Steven M.; Weber-Gasparoni, Karin

    2012-01-01

    Objective To assess and compare examiner reliability of clinical and photographic fluorosis examinations using the Fluorosis Risk Index (FRI) among children in the Iowa Fluoride Study (IFS). Methods The IFS examined 538 children for fluorosis and dental caries at age 13 and obtained intra-oral photographs from nearly all of them. To assess examiner reliability, duplicate clinical examinations were conducted for 40 of the subjects. In addition, 200 of the photographs were scored independently for fluorosis by two examiners in a standardized manner. Fluorosis data were compared between examiners for the clinical exams and separately for the photographic exams, and a comparison was made between clinical and photographic exams. For all 3 comparisons, examiner reliability was assessed using kappa statistics at the tooth level. Results Inter-examiner reliability for the duplicate clinical exams on the sample of 40 subjects as measured by kappa was 0.59, while the repeat exams of the 200 photographs yielded a kappa of 0.64. For the comparison of photographic and clinical exams, inter-examiner reliability, as measured by weighted kappa, was 0.46. FRI scores obtained using the photographs were higher on average than those obtained from the clinical exams. Fluorosis prevalence was higher for photographs (33%) than found for clinical exam (18%). Conclusion Results suggest inter-examiner reliability is greater and fluorosis scores higher when using photographic compared to clinical examinations. PMID:22316120

  16. The reliability of a modified Kalamazoo Consensus Statement Checklist for assessing the communication skills of multidisciplinary clinicians in the simulated environment.

    Science.gov (United States)

    Peterson, Eleanor B; Calhoun, Aaron W; Rider, Elizabeth A

    2014-09-01

    With increased recognition of the importance of sound communication skills and communication skills education, reliable assessment tools are essential. This study reports on the psychometric properties of an assessment tool based on the Kalamazoo Consensus Statement Essential Elements Communication Checklist. The Gap-Kalamazoo Communication Skills Assessment Form (GKCSAF), a modified version of an existing communication skills assessment tool, the Kalamazoo Essential Elements Communication Checklist-Adapted, was used to assess learners in a multidisciplinary, simulation-based communication skills educational program using multiple raters. 118 simulated conversations were available for analysis. Internal consistency and inter-rater reliability were determined by calculating a Cronbach's alpha score and intra-class correlation coefficients (ICC), respectively. The GKCSAF demonstrated high internal consistency with a Cronbach's alpha score of 0.844 (faculty raters) and 0.880 (peer observer raters), and high inter-rater reliability with an ICC of 0.830 (faculty raters) and 0.89 (peer observer raters). The Gap-Kalamazoo Communication Skills Assessment Form is a reliable method of assessing the communication skills of multidisciplinary learners using multi-rater methods within the learning environment. The Gap-Kalamazoo Communication Skills Assessment Form can be used by educational programs that wish to implement a reliable assessment and feedback system for a variety of learners. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. Improving the Reliability of Case-Based Reasoning Systems

    Directory of Open Access Journals (Sweden)

    Xu Xu

    2010-09-01

    also discussed in this paper, especially the property that whether inter-feature of case exists redundancy. After that, the reliability of an individual suggested solution is studied. To illustrate these ideas, some experiments and their results are discussed in this paper. The results of experiments show a new route concerning on how to improve the reliability of a CBR system at an overall level.

  18. Palliative sedation: reliability and validity of sedation scales.

    Science.gov (United States)

    Arevalo, Jimmy J; Brinkkemper, Tijn; van der Heide, Agnes; Rietjens, Judith A; Ribbe, Miel; Deliens, Luc; Loer, Stephan A; Zuurmond, Wouter W A; Perez, Roberto S G M

    2012-11-01

    Observer-based sedation scales have been used to provide a measurable estimate of the comfort of nonalert patients in palliative sedation. However, their usefulness and appropriateness in this setting has not been demonstrated. To study the reliability and validity of observer-based sedation scales in palliative sedation. A prospective evaluation of 54 patients under intermittent or continuous sedation with four sedation scales was performed by 52 nurses. Included scales were the Minnesota Sedation Assessment Tool (MSAT), Richmond Agitation-Sedation Scale (RASS), Vancouver Interaction and Calmness Scale (VICS), and a sedation score proposed in the Guideline for Palliative Sedation of the Royal Dutch Medical Association (KNMG). Inter-rater reliability was tested with the intraclass correlation coefficient (ICC) and Cohen's kappa coefficient. Correlations between the scales using Spearman's rho tested concurrent validity. We also examined construct, discriminative, and evaluative validity. In addition, nurses completed a user-friendliness survey. Overall moderate to high inter-rater reliability was found for the VICS interaction subscale (ICC = 0.85), RASS (ICC = 0.73), and KNMG (ICC = 0.71). The largest correlation between scales was found for the RASS and KNMG (rho = 0.836). All scales showed discriminative and evaluative validity, except for the MSAT motor subscale and VICS calmness subscale. Finally, the RASS was less time consuming, clearer, and easier to use than the MSAT and VICS. The RASS and KNMG scales stand as the most reliable and valid among the evaluated scales. In addition, the RASS was less time consuming, clearer, and easier to use than the MSAT and VICS. Further research is needed to evaluate the impact of the scales on better symptom control and patient comfort. Copyright © 2012 U.S. Cancer Pain Relief Committee. Published by Elsevier Inc. All rights reserved.

  19. Development and Psychometric Properties of an Assessment for Persons with Intellectual Disability--The InterRAI ID

    Science.gov (United States)

    Martin, Lynn; Hirdes, John P.; Fries, Brant E.; Smith, Trevor F.

    2007-01-01

    This paper describes the development of the interRAI-Intellectual Disability (interRAI ID), a comprehensive instrument that assesses all key domains of interest to service providers relative to a person with an intellectual disability (ID). The authors report on the reliability and validity of embedded scales for cognition, self-care, aggression,…

  20. Reliability of Single-Leg Balance and Landing Tests in Rugby Union; Prospect of Using Postural Control to Monitor Fatigue.

    Science.gov (United States)

    Troester, Jordan C; Jasmin, Jason G; Duffield, Rob

    2018-06-01

    The present study examined the inter-trial (within test) and inter-test (between test) reliability of single-leg balance and single-leg landing measures performed on a force plate in professional rugby union players using commercially available software (SpartaMARS, Menlo Park, USA). Twenty-four players undertook test - re-test measures on two occasions (7 days apart) on the first training day of two respective pre-season weeks following 48h rest and similar weekly training loads. Two 20s single-leg balance trials were performed on a force plate with eyes closed. Three single-leg landing trials were performed by jumping off two feet and landing on one foot in the middle of a force plate 1m from the starting position. Single-leg balance results demonstrated acceptable inter-trial reliability (ICC = 0.60-0.81, CV = 11-13%) for sway velocity, anterior-posterior sway velocity, and mediolateral sway velocity variables. Acceptable inter-test reliability (ICC = 0.61-0.89, CV = 7-13%) was evident for all variables except mediolateral sway velocity on the dominant leg (ICC = 0.41, CV = 15%). Single-leg landing results only demonstrated acceptable inter-trial reliability for force based measures of relative peak landing force and impulse (ICC = 0.54-0.72, CV = 9-15%). Inter-test results indicate improved reliability through the averaging of three trials with force based measures again demonstrating acceptable reliability (ICC = 0.58-0.71, CV = 7-14%). Of the variables investigated here, total sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing performance, respectively. These measures should be considered for monitoring potential changes in postural control in professional rugby union.

  1. Reliability of Single-Leg Balance and Landing Tests in Rugby Union; Prospect of Using Postural Control to Monitor Fatigue

    Directory of Open Access Journals (Sweden)

    Jordan C. Troester, Jason G. Jasmin, Rob Duffield

    2018-06-01

    Full Text Available The present study examined the inter-trial (within test and inter-test (between test reliability of single-leg balance and single-leg landing measures performed on a force plate in professional rugby union players using commercially available software (SpartaMARS, Menlo Park, USA. Twenty-four players undertook test – re-test measures on two occasions (7 days apart on the first training day of two respective pre-season weeks following 48h rest and similar weekly training loads. Two 20s single-leg balance trials were performed on a force plate with eyes closed. Three single-leg landing trials were performed by jumping off two feet and landing on one foot in the middle of a force plate 1m from the starting position. Single-leg balance results demonstrated acceptable inter-trial reliability (ICC = 0.60-0.81, CV = 11-13% for sway velocity, anterior-posterior sway velocity, and mediolateral sway velocity variables. Acceptable inter-test reliability (ICC = 0.61-0.89, CV = 7-13% was evident for all variables except mediolateral sway velocity on the dominant leg (ICC = 0.41, CV = 15%. Single-leg landing results only demonstrated acceptable inter-trial reliability for force based measures of relative peak landing force and impulse (ICC = 0.54-0.72, CV = 9-15%. Inter-test results indicate improved reliability through the averaging of three trials with force based measures again demonstrating acceptable reliability (ICC = 0.58-0.71, CV = 7-14%. Of the variables investigated here, total sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing performance, respectively. These measures should be considered for monitoring potential changes in postural control in professional rugby union.

  2. Reliability of standing weight-bearing (0.25T) MR imaging findings and positional changes in the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Bjarke B.; Bliddal, Henning [Department of Reumatology, Copenhagen University Hospital, The Parker Institute, Koebenhavn Oe (Denmark); Hansen, Philip; Christensen, Anders F.; Trampedach, Charlotte; Rasti, Zoreh; Boesen, Mikael [Copenhagen University Hospital, Department of Radiology, Koebenhavn Oe (Denmark)

    2018-01-15

    To test the reliability and absolute agreement of common degenerative findings in standing positional magnetic resonance imaging (pMRI). Low back pain patients with and without sciatica were consecutively enrolled to undergo a supine and standing pMRI. Three readers independently evaluated the standing pMRI for herniation, spinal stenosis, spondylolisthesis, HIZ lesions and facet joint effusion. The evaluation included a semi-quantitative grading of spinal stenosis, foraminal stenosis and spinal nerve root compression. The standing pMRI images were evaluated with full access to supine MRI. In case lower grades or the degenerative findings were not present in the supine images, this was reported separately as position-dependent changes. A subsample of 20 pMRI examinations was reevaluated after two months. The reproducibility was assessed by inter- and intra-reader reliability (kappa statistic) and absolute agreement between readers. Fifty-six patients were included in this study. There was fair-to-substantial inter-reader reliability (κ 0.47 to 0.82) and high absolute agreement (72.3% to 99.1%) for the pMRI findings. The intra-reader assessment showed similar reliability and agreement (κ 0.36 to 0.85; absolute agreement: 62.5% to 98.8%). Positional changes between the supine and standing position showed a fair-to-moderate inter- and intra-reader reliability (κ 0.25 to 0.52; absolute agreement: 97.0% to 99.1). Evaluation of the lumbar spine for degenerative findings by standing pMRI has acceptable reproducibility; however, positional changes from the supine to the standing position as an independent outcome should be interpreted with caution because of lower reliability, which calls for further standardisation. (orig.)

  3. Reliability of standing weight-bearing (0.25T) MR imaging findings and positional changes in the lumbar spine

    International Nuclear Information System (INIS)

    Hansen, Bjarke B.; Bliddal, Henning; Hansen, Philip; Christensen, Anders F.; Trampedach, Charlotte; Rasti, Zoreh; Boesen, Mikael

    2018-01-01

    To test the reliability and absolute agreement of common degenerative findings in standing positional magnetic resonance imaging (pMRI). Low back pain patients with and without sciatica were consecutively enrolled to undergo a supine and standing pMRI. Three readers independently evaluated the standing pMRI for herniation, spinal stenosis, spondylolisthesis, HIZ lesions and facet joint effusion. The evaluation included a semi-quantitative grading of spinal stenosis, foraminal stenosis and spinal nerve root compression. The standing pMRI images were evaluated with full access to supine MRI. In case lower grades or the degenerative findings were not present in the supine images, this was reported separately as position-dependent changes. A subsample of 20 pMRI examinations was reevaluated after two months. The reproducibility was assessed by inter- and intra-reader reliability (kappa statistic) and absolute agreement between readers. Fifty-six patients were included in this study. There was fair-to-substantial inter-reader reliability (κ 0.47 to 0.82) and high absolute agreement (72.3% to 99.1%) for the pMRI findings. The intra-reader assessment showed similar reliability and agreement (κ 0.36 to 0.85; absolute agreement: 62.5% to 98.8%). Positional changes between the supine and standing position showed a fair-to-moderate inter- and intra-reader reliability (κ 0.25 to 0.52; absolute agreement: 97.0% to 99.1). Evaluation of the lumbar spine for degenerative findings by standing pMRI has acceptable reproducibility; however, positional changes from the supine to the standing position as an independent outcome should be interpreted with caution because of lower reliability, which calls for further standardisation. (orig.)

  4. Reliability of standing weight-bearing (0.25T) MR imaging findings and positional changes in the lumbar spine.

    Science.gov (United States)

    Hansen, Bjarke B; Hansen, Philip; Christensen, Anders F; Trampedach, Charlotte; Rasti, Zoreh; Bliddal, Henning; Boesen, Mikael

    2018-01-01

    To test the reliability and absolute agreement of common degenerative findings in standing positional magnetic resonance imaging (pMRI). Low back pain patients with and without sciatica were consecutively enrolled to undergo a supine and standing pMRI. Three readers independently evaluated the standing pMRI for herniation, spinal stenosis, spondylolisthesis, HIZ lesions and facet joint effusion. The evaluation included a semi-quantitative grading of spinal stenosis, foraminal stenosis and spinal nerve root compression. The standing pMRI images were evaluated with full access to supine MRI. In case lower grades or the degenerative findings were not present in the supine images, this was reported separately as position-dependent changes. A subsample of 20 pMRI examinations was reevaluated after two months. The reproducibility was assessed by inter- and intra-reader reliability (kappa statistic) and absolute agreement between readers. Fifty-six patients were included in this study. There was fair-to-substantial inter-reader reliability (κ 0.47 to 0.82) and high absolute agreement (72.3% to 99.1%) for the pMRI findings. The intra-reader assessment showed similar reliability and agreement (κ 0.36 to 0.85; absolute agreement: 62.5% to 98.8%). Positional changes between the supine and standing position showed a fair-to-moderate inter- and intra-reader reliability (κ 0.25 to 0.52; absolute agreement: 97.0% to 99.1). Evaluation of the lumbar spine for degenerative findings by standing pMRI has acceptable reproducibility; however, positional changes from the supine to the standing position as an independent outcome should be interpreted with caution because of lower reliability, which calls for further standardisation.

  5. Development of high-reliability control system for nuclear power plants

    International Nuclear Information System (INIS)

    Asami, K.; Yanai, K.; Hirose, H.; Ito, T.

    1983-01-01

    In Japan, many nuclear power generating plants are in operation and under construction. There is a general awareness of the problems in connection with nuclear power generation and strong emphasis is put on achieving highly reliable operation of nuclear power plants. Hitachi has developed a new high-reliability control system. NURECS-3000 (NUclear Power Plant High-REliability Control System), which is applied to the main control systems, such as the reactor feedwater control system, the reactor recirculation control system and the main turbine control system. The NURECS-3000 system was designed taking into account the fact that there will be failures, but the aim is for the system to continue to function correctly; it is therefore a fault-tolerant system. It has redundant components which can be completely isolated from each other in order to prevent fault propagation. The system has a hierarchical configuration, with a main controller, consisting of a triplex microcomputer system, and sub-loop controllers. Special care was taken to ensure the independence of these subsystems. Since most of the redundant system failures are caused by common-mode failures and the reliability of redundant systems depends on the reliability of the common-mode parts, the aim was to minimize these parts. (author)

  6. Systematic evaluation of the teaching qualities of Obstetrics and Gynecology faculty: reliability and validity of the SETQ tools.

    Directory of Open Access Journals (Sweden)

    Renée van der Leeuw

    Full Text Available BACKGROUND: The importance of effective clinical teaching for the quality of future patient care is globally understood. Due to recent changes in graduate medical education, new tools are needed to provide faculty with reliable and individualized feedback on their teaching qualities. This study validates two instruments underlying the System for Evaluation of Teaching Qualities (SETQ aimed at measuring and improving the teaching qualities of obstetrics and gynecology faculty. METHODS AND FINDINGS: This cross-sectional multi-center questionnaire study was set in seven general teaching hospitals and two academic medical centers in the Netherlands. Seventy-seven residents and 114 faculty were invited to complete the SETQ instruments in the duration of one month from September 2008 to September 2009. To assess reliability and validity of the instruments, we used exploratory factor analysis, inter-item correlation, reliability coefficient alpha and inter-scale correlations. We also compared composite scales from factor analysis to global ratings. Finally, the number of residents' evaluations needed per faculty for reliable assessments was calculated. A total of 613 evaluations were completed by 66 residents (85.7% response rate. 99 faculty (86.8% response rate participated in self-evaluation. Factor analysis yielded five scales with high reliability (Cronbach's alpha for residents' and faculty: learning climate (0.86 and 0.75, professional attitude (0.89 and 0.81, communication of learning goals (0.89 and 0.82, evaluation of residents (0.87 and 0.79 and feedback (0.87 and 0.86. Item-total, inter-scale and scale-global rating correlation coefficients were significant (P<0.01. Four to six residents' evaluations are needed per faculty (reliability coefficient 0.60-0.80. CONCLUSIONS: Both SETQ instruments were found reliable and valid for evaluating teaching qualities of obstetrics and gynecology faculty. Future research should examine improvement of

  7. Link and route availability for Inter-working multi-hop wireless networks

    CSIR Research Space (South Africa)

    Salami, O

    2009-09-01

    Full Text Available pairs in inter-working multi-hop wireless networks can be evaluated based on the availability and reliability of radio links that form the communication path linking the nodes. This paper presents an analytical study of the link and route availability...

  8. High reliability megawatt transformer/rectifier

    Science.gov (United States)

    Zwass, Samuel; Ashe, Harry; Peters, John W.

    1991-01-01

    The goal of the two phase program is to develop the technology and design and fabricate ultralightweight high reliability DC to DC converters for space power applications. The converters will operate from a 5000 V dc source and deliver 1 MW of power at 100 kV dc. The power weight density goal is 0.1 kg/kW. The cycle to cycle voltage stability goals was + or - 1 percent RMS. The converter is to operate at an ambient temperature of -40 C with 16 minute power pulses and one hour off time. The uniqueness of the design in Phase 1 resided in the dc switching array which operates the converter at 20 kHz using Hollotron plasma switches along with a specially designed low loss, low leakage inductance and a light weight high voltage transformer. This approach reduced considerably the number of components in the converter thereby increasing the system reliability. To achieve an optimum transformer for this application, the design uses four 25 kV secondary windings to produce the 100 kV dc output, thus reducing the transformer leakage inductance, and the ac voltage stresses. A specially designed insulation system improves the high voltage dielectric withstanding ability and reduces the insulation path thickness thereby reducing the component weight. Tradeoff studies and tests conducted on scaled-down model circuits and using representative coil insulation paths have verified the calculated transformer wave shape parameters and the insulation system safety. In Phase 1 of the program a converter design approach was developed and a preliminary transformer design was completed. A fault control circuit was designed and a thermal profile of the converter was also developed.

  9. Achieving High Reliability Operations Through Multi-Program Integration

    Energy Technology Data Exchange (ETDEWEB)

    Holly M. Ashley; Ronald K. Farris; Robert E. Richards

    2009-04-01

    Over the last 20 years the Idaho National Laboratory (INL) has adopted a number of operations and safety-related programs which has each periodically taken its turn in the limelight. As new programs have come along there has been natural competition for resources, focus and commitment. In the last few years, the INL has made real progress in integrating all these programs and are starting to realize important synergies. Contributing to this integration are both collaborative individuals and an emerging shared vision and goal of the INL fully maturing in its high reliability operations. This goal is so powerful because the concept of high reliability operations (and the resulting organizations) is a masterful amalgam and orchestrator of the best of all the participating programs (i.e. conduct of operations, behavior based safety, human performance, voluntary protection, quality assurance, and integrated safety management). This paper is a brief recounting of the lessons learned, thus far, at the INL in bringing previously competing programs into harmony under the goal (umbrella) of seeking to perform regularly as a high reliability organization. In addition to a brief diagram-illustrated historical review, the authors will share the INL’s primary successes (things already effectively stopped or started) and the gaps yet to be bridged.

  10. Construct validity and inter-rater reliability of the Dutch activity measure for post-acute care "6-clicks" basic mobility form to assess the mobility of hospitalized patients.

    Science.gov (United States)

    Geelen, Sven Jacobus Gertruda; Valkenet, Karin; Veenhof, Cindy

    2018-05-12

    To evaluate the construct validity and the inter-rater reliability of the Dutch Activity Measure for Post-Acute Care "6-clicks" Basic Mobility short form measuring the patient's mobility in Dutch hospital care. First, the "6-clicks" was translated by using a forward-backward translation protocol. Next, 64 patients were assessed by the physiotherapist to determine the validity while being admitted to the Internal Medicine wards of a university medical center. Six hypotheses were tested regarding the construct "mobility" which showed that: Better "6-clicks" scores were related to less restrictive pre-admission living situations (p = 0.011), less restrictive discharge locations (p = 0.001), more independence in activities of daily living (p = 0.001) and less physiotherapy visits (p Dutch "6-clicks" shows a good construct validity and moderate-to-excellent inter-rater reliability when used to assess the mobility of hospitalized patients. Implications for Rehabilitation Even though various measurement tools have been developed, it appears the majority of physiotherapists working in a hospital currently do not use these tools as a standard part of their care. The Activity Measure for Post-Acute Care "6-clicks" Basic Mobility is the only tool which is designed to be short, easy to use within usual care and has been validated in the entire hospital population. This study shows that the Dutch version of the Activity Measure for Post-Acute Care "6-clicks" Basic Mobility form is a valid, easy to use, quick tool to assess the basic mobility of Dutch hospitalized patients.

  11. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Quality Assurance Manual

    Energy Technology Data Exchange (ETDEWEB)

    C. L. Smith; R. Nims; K. J. Kvarfordt; C. Wharton

    2008-08-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment using a personal computer running the Microsoft Windows operating system. SAPHIRE is primarily funded by the U.S. Nuclear Regulatory Commission (NRC). The role of the INL in this project is that of software developer and tester. This development takes place using formal software development procedures and is subject to quality assurance (QA) processes. The purpose of this document is to describe how the SAPHIRE software QA is performed for Version 6 and 7, what constitutes its parts, and limitations of those processes.

  12. High Reliability Cryogenic Piezoelectric Valve Actuator, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Cryogenic fluid valves are subject to harsh exposure and actuators to drive these valves require robust performance and high reliability. DSM's piezoelectric...

  13. Inter-crosslinking network gels having both shape memory and high ductility

    Science.gov (United States)

    Amano, Yoshitaka; Hidema, Ruri; Furukawa, Hidemitsu

    2012-04-01

    Medical treatment for injuries should be easy and quick in many accidents. Plasters or bandages are frequently used to wrap and fix injured parts. If plasters or bandages have additional smart functions, such as cooling, removability and repeatability, they will be much more useful and effective. Here we propose innovative biocompatible materials, that is, nontoxic high-strength shape-memory gels as novel smart medical materials. These smart gels were prepared from two monomers (DMAAm and SA), a polymer (HPC), and an inter-crosslinking agent (Karenz-MOI). In the synthesis of the gels, 1) a shape-memory copolymer network is made from the DMAAm and the SA, and 2) the copolymer and the HPC are crosslinked by the Karenz-MOI. Thus the crosslinking points are connected only between the different polymers. This is our original technique of developing a new network structure of gels, named Inter-Crosslinking Network (ICN). The ICN gels achieve high ductility, going up to 700% strain in tensile tests, while the ICN gels contain about 44% water. Moreover the SA has temperature dependence due to its crystallization properties; thus the ICN gels obtain shape memory properties and are named ICN-SMG. While the Young's modulus of the ICN-SMG is large below their crystallization temperature and the gels behave like plastic materials, the modulus becomes smaller above the temperature and the gels turn back to their original shape.

  14. Computational Fluid Dynamics Simulation of Hydrodynamics and Stresses in the PhEur/USP Disintegration Tester Under Fed and Fasted Fluid Characteristics.

    Science.gov (United States)

    Kindgen, Sarah; Wachtel, Herbert; Abrahamsson, Bertil; Langguth, Peter

    2015-09-01

    Disintegration of oral solid dosage forms is a prerequisite for drug dissolution and absorption and is to a large extent dependent on the pressures and hydrodynamic conditions in the solution that the dosage form is exposed to. In this work, the hydrodynamics in the PhEur/USP disintegration tester were investigated using computational fluid dynamics (CFD). Particle image velocimetry was used to validate the CFD predictions. The CFD simulations were performed with different Newtonian and non-Newtonian fluids, representing fasted and fed states. The results indicate that the current design and operating conditions of the disintegration test device, given by the pharmacopoeias, are not reproducing the in vivo situation. This holds true for the hydrodynamics in the disintegration tester that generates Reynolds numbers dissimilar to the reported in vivo situation. Also, when using homogenized US FDA meal, representing the fed state, too high viscosities and relative pressures are generated. The forces acting on the dosage form are too small for all fluids compared to the in vivo situation. The lack of peristaltic contractions, which generate hydrodynamics and shear stress in vivo, might be the major drawback of the compendial device resulting in the observed differences between predicted and in vivo measured hydrodynamics. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.

  15. Beyond redundancy how geographic redundancy can improve service availability and reliability of computer-based systems

    CERN Document Server

    Bauer, Eric; Eustace, Dan

    2012-01-01

    "While geographic redundancy can obviously be a huge benefit for disaster recovery, it is far less obvious what benefit is feasible and likely for more typical non-catastrophic hardware, software, and human failures. Georedundancy and Service Availability provides both a theoretical and practical treatment of the feasible and likely benefits of geographic redundancy for both service availability and service reliability. The text provides network/system planners, IS/IT operations folks, system architects, system engineers, developers, testers, and other industry practitioners with a general discussion about the capital expense/operating expense tradeoff that frames system redundancy and georedundancy"--

  16. Assessment of the nursing care product (APROCENF: a reliability and construct validity study

    Directory of Open Access Journals (Sweden)

    Danielle Fabiana Cucolo

    Full Text Available ABSTRACT Objectives: to verify the reliability and construct validity estimates of the "Assessment of nursing care product" scale (APROCENF and its applicability. Methods: this validation study included a sample of 40 (inter-rater reliability and 172 (construct validity assessments performed by nurses at the end of the work shift at nine inpatient services of a teaching hospital in the Brazilian Southeast. The data were collected between February and September/2014 with interruptions. Cronbach's alpha and Spearman's correlation coefficients were calculated, as well as the intraclass correlation and the weighted kappa index (inter-rater reliability. Exploratory factor analysis was used with principal component extraction and varimax rotation (construct validity. Results: the internal consistency revealed an alpha coefficient of 0.85, item-item correlation ranging between 0.13 and 0.61 and item-total correlation between 0.43 and 0.69. Inter-rater equivalence was obtained and all items evidenced significant factor loadings. Conclusion: this research evidenced the reliability and construct validity of the scale to assess the nursing care product. Its application in nursing practice permits identifying improvements needed in the production process, contributing to management and care decisions.

  17. Reliability of digital ulcer definitions as proposed by the UK Scleroderma Study Group: A challenge for clinical trial design.

    Science.gov (United States)

    Hughes, Michael; Tracey, Andrew; Bhushan, Monica; Chakravarty, Kuntal; Denton, Christopher P; Dubey, Shirish; Guiducci, Serena; Muir, Lindsay; Ong, Voon; Parker, Louise; Pauling, John D; Prabu, Athiveeraramapandian; Rogers, Christine; Roberts, Christopher; Herrick, Ariane L

    2018-06-01

    The reliability of clinician grading of systemic sclerosis-related digital ulcers has been reported to be poor to moderate at best, which has important implications for clinical trial design. The aim of this study was to examine the reliability of new proposed UK Scleroderma Study Group digital ulcer definitions among UK clinicians with an interest in systemic sclerosis. Raters graded (through a custom-built interface) 90 images (80 unique and 10 repeat) of a range of digital lesions collected from patients with systemic sclerosis. Lesions were graded on an ordinal scale of severity: 'no ulcer', 'healed ulcer' or 'digital ulcer'. A total of 23 clinicians - 18 rheumatologists, 3 dermatologists, 1 hand surgeon and 1 specialist rheumatology nurse - completed the study. A total of 2070 (1840 unique + 230 repeat) image gradings were obtained. For intra-rater reliability, across all images, the overall weighted kappa coefficient was high (0.71) and was moderate (0.55) when averaged across individual raters. Overall inter-rater reliability was poor (0.15). Although our proposed digital ulcer definitions had high intra-rater reliability, the overall inter-rater reliability was poor. Our study highlights the challenges of digital ulcer assessment by clinicians with an interest in systemic sclerosis and provides a number of useful insights for future clinical trial design. Further research is warranted to improve the reliability of digital ulcer definition/rating as an outcome measure in clinical trials, including examining the role for objective measurement techniques, and the development of digital ulcer patient-reported outcome measures.

  18. Assessment of dental anomalies on panoramic radiographs: inter- and intraexaminer agreement

    NARCIS (Netherlands)

    van Parys, K.; Aartman, I.H.A.; Kuitert, R.; Zentner, A.

    2011-01-01

    The presence of dental anomalies has been rated radiographically in a number of studies. However, since the reliability of the assessment of these anomalies has rarely been investigated, the aim of this study was to examine inter- and intraexaminer agreement in identifying morphological dental

  19. Inter- and intraobserver reliability of the MTM-classification for proximal humeral fractures

    DEFF Research Database (Denmark)

    Bahrs, Christian; Schmal, Hagen; Lingenfelter, Erich

    2008-01-01

    tool. METHODS: Three observers classified plain radiographs of 22 fractures using both a simple version (fracture displacement, number of parts) and an extensive version (individual topographic fracture type and morphology) of the MTM classification. Kappa-statistics were used to determine reliability....... RESULTS: An acceptable reliability was found for the simple version classifying fracture displacement and fractured main parts. Fair interobserver agreement was found for the extensive version with individual topographic fracture type and morphology. CONCLUSION: Although the MTM-classification covers...

  20. Reliability of Multi-Category Rating Scales

    Science.gov (United States)

    Parker, Richard I.; Vannest, Kimberly J.; Davis, John L.

    2013-01-01

    The use of multi-category scales is increasing for the monitoring of IEP goals, classroom and school rules, and Behavior Improvement Plans (BIPs). Although they require greater inference than traditional data counting, little is known about the inter-rater reliability of these scales. This simulation study examined the performance of nine…

  1. Reliability of Patient-Led Screening with the Malnutrition Screening Tool: Agreement between Patient and Health Care Professional Scores in the Cancer Care Ambulatory Setting.

    Science.gov (United States)

    Di Bella, Alexandra; Blake, Claire; Young, Adrienne; Pelecanos, Anita; Brown, Teresa

    2018-02-01

    The prevalence of malnutrition in patients with cancer is reported as high as 60% to 80%, and malnutrition is associated with lower survival, reduced response to treatment, and poorer functional status. The Malnutrition Screening Tool (MST) is a validated tool when administered by health care professionals; however, it has not been evaluated for patient-led screening. This study aims to assess the reliability of patient-led MST screening through assessment of inter-rater reliability between patient-led and dietitian-researcher-led screening and intra-rater reliability between an initial and a repeat patient screening. This cross-sectional study included 208 adults attending ambulatory cancer care services in a metropolitan teaching hospital in Queensland, Australia, in October 2016 (n=160 inter-rater reliability; n=48 intra-rater reliability measured in a separate sample). Primary outcome measures were MST risk categories (MST 0-1: not at risk, MST ≥2: at risk) as determined by screening completed by patients and a dietitian-researcher, patient test-retest screening, and patient acceptability. Percent and chance-corrected agreement (Cohen's kappa coefficient, κ) were used to determine agreement between patient-MST and dietitian-MST (inter-rater reliability) and MST completed by patient on admission to unit (patient-MSTA) and MST completed by patient 1 to 3 hours after completion of initial MST (patient-MSTB) (intra-rater reliability). High inter-rater reliability and intra-rater reliability were observed. Agreement between patient-MST and dietitian-MST was 96%, with "almost perfect" chance-adjusted agreement (κ=0.92, 95% CI 0.84 to 0.97). Agreement between repeated patient-MSTA and patient-MSTB was 94%, with "almost perfect" chance-adjusted agreement (κ=0.88, 95% CI 0.71 to 1.00). Based on dietitian-MST, 33% (n=53) of patients were identified as being at risk for malnutrition, and 40% of these reported not seeing a dietitian. Of 156 patients who provided

  2. High-Reliable PLC RTOS Development and RPS Structure Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, H. S.; Song, D. Y.; Sohn, D. S.; Kim, J. H. [Enersys Co., Daejeon (Korea, Republic of)

    2008-04-15

    One of the KNICS objectives is to develop a platform for Nuclear Power Plant(NPP) I and C(Instrumentation and Control) system, especially plant protection system. The developed platform is POSAFE-Q and this work supports the development of POSAFE-Q with the development of high-reliable real-time operating system(RTOS) and programmable logic device(PLD) software. Another KNICS objective is to develop safety I and C systems, such as Reactor Protection System(RPS) and Engineered Safety Feature-Component Control System(ESF-CCS). This work plays an important role in the structure analysis for RPS. Validation and verification(V and V) of the safety critical software is an essential work to make digital plant protection system highly reliable and safe. Generally, the reliability and safety of software based system can be improved by strict quality assurance framework including the software development itself. In other words, through V and V, the reliability and safety of a system can be improved and the development activities like software requirement specification, software design specification, component tests, integration tests, and system tests shall be appropriately documented for V and V.

  3. High-Reliable PLC RTOS Development and RPS Structure Analysis

    International Nuclear Information System (INIS)

    Sohn, H. S.; Song, D. Y.; Sohn, D. S.; Kim, J. H.

    2008-04-01

    One of the KNICS objectives is to develop a platform for Nuclear Power Plant(NPP) I and C(Instrumentation and Control) system, especially plant protection system. The developed platform is POSAFE-Q and this work supports the development of POSAFE-Q with the development of high-reliable real-time operating system(RTOS) and programmable logic device(PLD) software. Another KNICS objective is to develop safety I and C systems, such as Reactor Protection System(RPS) and Engineered Safety Feature-Component Control System(ESF-CCS). This work plays an important role in the structure analysis for RPS. Validation and verification(V and V) of the safety critical software is an essential work to make digital plant protection system highly reliable and safe. Generally, the reliability and safety of software based system can be improved by strict quality assurance framework including the software development itself. In other words, through V and V, the reliability and safety of a system can be improved and the development activities like software requirement specification, software design specification, component tests, integration tests, and system tests shall be appropriately documented for V and V.

  4. The reliability and validity of video analysis for the assessment of the clinical signs of concussion in Australian football.

    Science.gov (United States)

    Makdissi, Michael; Davis, Gavin

    2016-10-01

    The objective of this study was to determine the reliability and validity of identifying clinical signs of concussion using video analysis in Australian football. Prospective cohort study. All impacts and collisions potentially resulting in a concussion were identified during 2012 and 2013 Australian Football League seasons. Consensus definitions were developed for clinical signs associated with concussion. For intra- and inter-rater reliability analysis, two experienced clinicians independently assessed 102 randomly selected videos on two occasions. Sensitivity, specificity, positive and negative predictive values were calculated based on the diagnosis provided by team medical staff. 212 incidents resulting in possible concussion were identified in 414 Australian Football League games. The intra-rater reliability of the video-based identification of signs associated with concussion was good to excellent. Inter-rater reliability was good to excellent for impact seizure, slow to get up, motor incoordination, ragdoll appearance (2 of 4 analyses), clutching at head and facial injury. Inter-rater reliability for loss of responsiveness and blank and vacant look was only fair and did not reach statistical significance. The feature with the highest sensitivity was slow to get up (87%), but this sign had a low specificity (19%). Other video signs had a high specificity but low sensitivity. Blank and vacant look (100%) and motor incoordination (81%) had the highest positive predictive value. Video analysis may be a useful adjunct to the side-line assessment of a possible concussion. Video analysis however should not replace the need for a thorough multimodal clinical assessment. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  5. Is One Trial Sufficient to Obtain Excellent Pressure Pain Threshold Reliability in the Low Back of Asymptomatic Individuals? A Test-Retest Study.

    Science.gov (United States)

    Balaguier, Romain; Madeleine, Pascal; Vuillerme, Nicolas

    2016-01-01

    The assessment of pressure pain threshold (PPT) provides a quantitative value related to the mechanical sensitivity to pain of deep structures. Although excellent reliability of PPT has been reported in numerous anatomical locations, its absolute and relative reliability in the lower back region remains to be determined. Because of the high prevalence of low back pain in the general population and because low back pain is one of the leading causes of disability in industrialized countries, assessing pressure pain thresholds over the low back is particularly of interest. The purpose of this study study was (1) to evaluate the intra- and inter- absolute and relative reliability of PPT within 14 locations covering the low back region of asymptomatic individuals and (2) to determine the number of trial required to ensure reliable PPT measurements. Fifteen asymptomatic subjects were included in this study. PPTs were assessed among 14 anatomical locations in the low back region over two sessions separated by one hour interval. For the two sessions, three PPT assessments were performed on each location. Reliability was assessed computing intraclass correlation coefficients (ICC), standard error of measurement (SEM) and minimum detectable change (MDC) for all possible combinations between trials and sessions. Bland-Altman plots were also generated to assess potential bias in the dataset. Relative reliability for both intra- and inter- session was almost perfect with ICC ranged from 0.85 to 0.99. With respect to the intra-session, no statistical difference was reported for ICCs and SEM regardless of the conducted comparisons between trials. Conversely, for inter-session, ICCs and SEM values were significantly larger when two consecutive PPT measurements were used for data analysis. No significant difference was observed for the comparison between two consecutive measurements and three measurements. Excellent relative and absolute reliabilities were reported for both intra

  6. An objective spinal motion imaging assessment (OSMIA): reliability, accuracy and exposure data.

    Science.gov (United States)

    Breen, Alan C; Muggleton, Jennifer M; Mellor, Fiona E

    2006-01-04

    Minimally-invasive measurement of continuous inter-vertebral motion in clinical settings is difficult to achieve. This paper describes the reliability, validity and radiation exposure levels in a new Objective Spinal Motion Imaging Assessment system (OSMIA) based on low-dose fluoroscopy and image processing. Fluoroscopic sequences in coronal and sagittal planes were obtained from 2 calibration models using dry lumbar vertebrae, plus the lumbar spines of 30 asymptomatic volunteers. Calibration model 1 (mobile) was screened upright, in 7 inter-vertebral positions. The volunteers and calibration model 2 (fixed) were screened on a motorized table comprising 2 horizontal sections, one of which moved through 80 degrees. Model 2 was screened during motion 5 times and the L2-S1 levels of the volunteers twice. Images were digitised at 5fps. Inter-vertebral motion from model 1 was compared to its pre-settings to investigate accuracy. For volunteers and model 2, the first digitised image in each sequence was marked with templates. Vertebrae were tracked throughout the motion using automated frame-to-frame registration. For each frame, vertebral angles were subtracted giving inter-vertebral motion graphs. Volunteer data were acquired twice on the same day and analysed by two blinded observers. The root-mean-square (RMS) differences between paired data were used as the measure of reliability. RMS difference between reference and computed inter-vertebral angles in model 1 was 0.32 degrees for side-bending and 0.52 degrees for flexion-extension. For model 2, X-ray positioning contributed more to the variance of range measurement than did automated registration. For volunteer image sequences, RMS inter-observer variation in intervertebral motion range in the coronal plane was 1.86 degrees and intra-subject biological variation was between 2.75 degrees and 2.91 degrees. RMS inter-observer variation in the sagittal plane was 1.94 degrees. Radiation dosages in each view were below

  7. Analysis and Ranking of Protein-Protein Docking Models Using Inter-Residue Contacts and Inter-Molecular Contact Maps

    KAUST Repository

    Oliva, Romina; Chermak, Edrisse; Cavallo, Luigi

    2015-01-01

    In view of the increasing interest both in inhibitors of protein-protein interactions and in protein drugs themselves, analysis of the three-dimensional structure of protein-protein complexes is assuming greater relevance in drug design. In the many cases where an experimental structure is not available, protein-protein docking becomes the method of choice for predicting the arrangement of the complex. However, reliably scoring protein-protein docking poses is still an unsolved problem. As a consequence, the screening of many docking models is usually required in the analysis step, to possibly single out the correct ones. Here, making use of exemplary cases, we review our recently introduced methods for the analysis of protein complex structures and for the scoring of protein docking poses, based on the use of inter-residue contacts and their visualization in inter-molecular contact maps. We also show that the ensemble of tools we developed can be used in the context of rational drug design targeting protein-protein interactions.

  8. Analysis and Ranking of Protein-Protein Docking Models Using Inter-Residue Contacts and Inter-Molecular Contact Maps

    KAUST Repository

    Oliva, Romina

    2015-07-01

    In view of the increasing interest both in inhibitors of protein-protein interactions and in protein drugs themselves, analysis of the three-dimensional structure of protein-protein complexes is assuming greater relevance in drug design. In the many cases where an experimental structure is not available, protein-protein docking becomes the method of choice for predicting the arrangement of the complex. However, reliably scoring protein-protein docking poses is still an unsolved problem. As a consequence, the screening of many docking models is usually required in the analysis step, to possibly single out the correct ones. Here, making use of exemplary cases, we review our recently introduced methods for the analysis of protein complex structures and for the scoring of protein docking poses, based on the use of inter-residue contacts and their visualization in inter-molecular contact maps. We also show that the ensemble of tools we developed can be used in the context of rational drug design targeting protein-protein interactions.

  9. Inter-observer agreement in audit of quality of radiology requests and reports

    International Nuclear Information System (INIS)

    Stavem, K.; Foss, T.; Botnmark, O.; Andersen, O.K.; Erikssen, J.

    2004-01-01

    AIMS: To assess the quality of the imaging procedure requests and radiologists' reports using an auditing tool, and to assess the agreement between different observers of the quality parameters. MATERIALS AND METHODS: In an audit using a standardized scoring system, three observers reviewed request forms for 296 consecutive radiological examinations, and two observers reviewed a random sample of 150 of the corresponding radiologists' reports. We present descriptive statistics from the audit and pairwise inter-observer agreement, using the proportion agreement and kappa statistics. RESULTS: The proportion of acceptable item scores (0 or +1) was above 70% for all items except the requesting physician's bleep or extension number, legibility of the physician's name, or details about previous investigations. For pairs of observers, the inter-observer agreement was generally high, however, the corresponding kappa values were consistently low with only 14 of 90 ratings >0.60 and 6 >0.80 on the requests/reports. For the quality of the clinical information, the appropriateness of the request, and the requested priority/timing of the investigation items, the mean percentage agreement ranged 67-76, and the corresponding kappa values ranged 0.08-0.24. CONCLUSION: The inter-observer reliability of scores on the different items showed a high degree of agreement, although the kappa values were low, which is a well-known paradox. Current routines for requesting radiology examinations appeared satisfactory, although several problem areas were identified

  10. Fundamental Tradeoffs among Reliability, Latency and Throughput in Cellular Networks

    DEFF Research Database (Denmark)

    Soret, Beatriz; Mogensen, Preben; Pedersen, Klaus I.

    2014-01-01

    We address the fundamental tradeoffs among latency, reliability and throughput in a cellular network. The most important elements influencing the KPIs in a 4G network are identified, and the inter-relationships among them is discussed. We use the effective bandwidth and the effective capacity......, in which latency and reliability will be two of the principal KPIs....

  11. High pressure, high current, low inductance, high reliability sealed terminals

    Science.gov (United States)

    Hsu, John S [Oak Ridge, TN; McKeever, John W [Oak Ridge, TN

    2010-03-23

    The invention is a terminal assembly having a casing with at least one delivery tapered-cone conductor and at least one return tapered-cone conductor routed there-through. The delivery and return tapered-cone conductors are electrically isolated from each other and positioned in the annuluses of ordered concentric cones at an off-normal angle. The tapered cone conductor service can be AC phase conductors and DC link conductors. The center core has at least one service conduit of gate signal leads, diagnostic signal wires, and refrigerant tubing routed there-through. A seal material is in direct contact with the casing inner surface, the tapered-cone conductors, and the service conduits thereby hermetically filling the interstitial space in the casing interior core and center core. The assembly provides simultaneous high-current, high-pressure, low-inductance, and high-reliability service.

  12. Assessment of Advanced Life Support competence when combining different test methods--reliability and validity

    DEFF Research Database (Denmark)

    Ringsted, C; Lippert, F; Hesselfeldt, R

    2007-01-01

    Cardiac Arrest Simulation Test (CASTest) scenarios for the assessments according to guidelines 2005. AIMS: To analyse the reliability and validity of the individual sub-tests provided by ERC and to find a combination of MCQ and CASTest that provides a reliable and valid single effect measure of ALS...... that possessed high reliability, equality of test sets, and ability to discriminate between the two groups of supposedly different ALS competence. CONCLUSIONS: ERC sub-tests of ALS competence possess sufficient reliability and validity. A combined ALS score with equal weighting of one MCQ and one CASTest can...... competence. METHODS: Two groups of participants were included in this randomised, controlled experimental study: a group of newly graduated doctors, who had not taken the ALS course (N=17) and a group of students, who had passed the ALS course 9 months before the study (N=16). Reliability in terms of inter...

  13. Assessing high reliability via Bayesian approach and accelerated tests

    International Nuclear Information System (INIS)

    Erto, Pasquale; Giorgio, Massimiliano

    2002-01-01

    Sometimes the assessment of very high reliability levels is difficult for the following main reasons: - the high reliability level of each item makes it impossible to obtain, in a reasonably short time, a sufficient number of failures; - the high cost of the high reliability items to submit to life tests makes it unfeasible to collect enough data for 'classical' statistical analyses. In the above context, this paper presents a Bayesian solution to the problem of estimation of the parameters of the Weibull-inverse power law model, on the basis of a limited number (say six) of life tests, carried out at different stress levels, all higher than the normal one. The over-stressed (i.e. accelerated) tests allow the use of experimental data obtained in a reasonably short time. The Bayesian approach enables one to reduce the required number of failures adding to the failure information the available a priori engineers' knowledge. This engineers' involvement conforms to the most advanced management policy that aims at involving everyone's commitment in order to obtain total quality. A Monte Carlo study of the non-asymptotic properties of the proposed estimators and a comparison with the properties of maximum likelihood estimators closes the work

  14. Human reliability in high dose rate afterloading radiotherapy based on FMECA

    International Nuclear Information System (INIS)

    Deng Jun; Fan Yaohua; Yue Baorong; Wei Kedao; Ren Fuli

    2012-01-01

    Objective: To put forward reasonable and feasible recommendations against the procedure with relative high risk during the high dose rate (HDR) afterloading radiotherapy, so as to enhance its clinical application safety, through studying the human reliability in the process of carrying out the HDR afterloading radiotherapy. Methods: Basic data were collected by on-site investigation and process analysis as well as expert evaluation. Failure mode, effect and criticality analysis (FMECA) employed to study the human reliability in the execution of HDR afterloading radiotherapy. Results: The FMECA model of human reliability for HDR afterloading radiotherapy was established, through which 25 procedures with relative high risk index were found,accounting for 14.1% of total 177 procedures. Conclusions: FMECA method in human reliability study for HDR afterloading radiotherapy is feasible. The countermeasures are put forward to reduce the human error, so as to provide important basis for enhancing clinical application safety of HDR afterloading radiotherapy. (authors)

  15. Reliability studies of high operating temperature MCT photoconductor detectors

    Science.gov (United States)

    Wang, Wei; Xu, Jintong; Zhang, Yan; Li, Xiangyang

    2010-10-01

    This paper concerns HgCdTe (MCT) infrared photoconductor detectors with high operating temperature. The near room temperature operation of detectors have advantages of light weight, less cost and convenient usage. Their performances are modest and they suffer from reliable problems. These detectors face with stability of the package, chip bonding area and passivation layers. It's important to evaluate and improve the reliability of such detectors. Defective detectors were studied with SEM(Scanning electron microscope) and microscopy. Statistically significant differences were observed between the influence of operating temperature and the influence of humidity. It was also found that humility has statistically significant influence upon the stability of the chip bonding and passivation layers, and the amount of humility isn't strongly correlated to the damage on the surface. Considering about the commonly found failures modes in detectors, special test structures were designed to improve the reliability of detectors. An accelerated life test was also implemented to estimate the lifetime of the high operating temperature MCT photoconductor detectors.

  16. Investigation of reliability attributes and accelerated stress factors on terrestrial solar cells

    Science.gov (United States)

    Lathrop, J. W.; Prince, J. L.

    1980-04-01

    Three tasks were undertaken to investigate reliability attributes of terrestrial solar cells: (1) a study of the electrical behavior of cells in the second (reverse) quadrant; (2) the accelerated stress testing of three new state-of-the-art cells; and (3) the continued bias-temperature testing of four block 2 type silicon cells at 78 C and 135 C. Electrical characteristics measured in the second quadrant were determined to be a function of the cell's thermal behavior with breakdown depending on the initiation of localized heating. This implied that high breakdown cells may be more fault tolerant when forced to operate in the second quadrant, a result contrary to conventional thinking. The accelerated stress tests used in the first (power) quadrant were bias-temperature, bias-temperature-humidity, temperature-humidity, thermal shock, and thermal cycle. The new type cells measured included an EFG cell, a polycrystalline cell, and a Czochralski cell. Significant differences in the response to the various tests were observed between cell types. A microprocessed controlled, short interval solar cell tester was designed and construction initiated on a prototype.

  17. Medizinbibliotheken: inter:disziplinär – inter:national –inter:aktiv

    Directory of Open Access Journals (Sweden)

    Bauer, Bruno

    2017-12-01

    Full Text Available The focus of the current issue 3/2017 of GMS Medizin – Bibliothek – Information is the annual conference 2017 of the German Medical Libraries Association in Vienna. The motto of the conference was “Medical Libraries: inter:disciplinary – inter:national – inter:active”. The authors in this issue are Bruno Bauer (Austrian Transition to Open Access 2017–2020, Beata Górczynska (Development and structure of Polish veterinary school system and its libraries, Katharina Heldt, Henriette Senst & Jessica Riedel (Salon on the institute’s history: outstanding artifacts. 28.01.2016 to 15.12.2016, Jutta Matrisciano, Martina Semmler-Schmetz & Saskia Rohmer (Advice – From info snack to special menu: Solutions of the MedMA-Bib, Stefan Nortmann (The ‘Ersti-Café’ of the Medical Branch Library Münster, Sandra Rümmele (Toolbox: The new teaching library project of the Central Medical Library of the University Medical Center Hamburg-Eppendorf, Eva Seidlmayer & Christoph Poley (One Health – Transdisciplinarity at ZB MED and Heike Andermann (“Medical Libraries: inter:disciplinary – inter:national – inter:active”. Annual Meeting of the German Medical Library Association (AGMB, September 25 to 27, 2017 in Vienna. Furthermore this focus issue features articles from Stefan Grün & Christoph Poley (Statistical evaluation of semantic entities from metadata and full text on German Medical Science corpora and Iris Reimann (German MLA News; Competition of the German MLA Pioneer projects in medical libraries 2017: Introduction of the winners; Competition of the German MLA (AGMB Pioneer projects in medical libraries 2018 – Announcement.

  18. Systematic evaluation of the teaching qualities of Obstetrics and Gynecology faculty: reliability and validity of the SETQ tools.

    Science.gov (United States)

    van der Leeuw, Renée; Lombarts, Kiki; Heineman, Maas Jan; Arah, Onyebuchi

    2011-05-03

    The importance of effective clinical teaching for the quality of future patient care is globally understood. Due to recent changes in graduate medical education, new tools are needed to provide faculty with reliable and individualized feedback on their teaching qualities. This study validates two instruments underlying the System for Evaluation of Teaching Qualities (SETQ) aimed at measuring and improving the teaching qualities of obstetrics and gynecology faculty. This cross-sectional multi-center questionnaire study was set in seven general teaching hospitals and two academic medical centers in the Netherlands. Seventy-seven residents and 114 faculty were invited to complete the SETQ instruments in the duration of one month from September 2008 to September 2009. To assess reliability and validity of the instruments, we used exploratory factor analysis, inter-item correlation, reliability coefficient alpha and inter-scale correlations. We also compared composite scales from factor analysis to global ratings. Finally, the number of residents' evaluations needed per faculty for reliable assessments was calculated. A total of 613 evaluations were completed by 66 residents (85.7% response rate). 99 faculty (86.8% response rate) participated in self-evaluation. Factor analysis yielded five scales with high reliability (Cronbach's alpha for residents' and faculty): learning climate (0.86 and 0.75), professional attitude (0.89 and 0.81), communication of learning goals (0.89 and 0.82), evaluation of residents (0.87 and 0.79) and feedback (0.87 and 0.86). Item-total, inter-scale and scale-global rating correlation coefficients were significant (Pteaching qualities of obstetrics and gynecology faculty. Future research should examine improvement of teaching qualities when using SETQ.

  19. Replicable Interprofessional Competency Outcomes from High-Volume, Inter-Institutional, Interprofessional Simulation.

    Science.gov (United States)

    Bambini, Deborah; Emery, Matthew; de Voest, Margaret; Meny, Lisa; Shoemaker, Michael J

    2016-10-25

    There are significant limitations among the few prior studies that have examined the development and implementation of interprofessional education (IPE) experiences to accommodate a high volume of students from several disciplines and from different institutions. The present study addressed these gaps by seeking to determine the extent to which a single, large, inter-institutional, and IPE simulation event improves student perceptions of the importance and relevance of IPE and simulation as a learning modality, whether there is a difference in students' perceptions among disciplines, and whether the results are reproducible. A total of 290 medical, nursing, pharmacy, and physical therapy students participated in one of two large, inter-institutional, IPE simulation events. Measurements included student perceptions about their simulation experience using the Attitude Towards Teamwork in Training Undergoing Designed Educational Simulation (ATTITUDES) Questionnaire and open-ended questions related to teamwork and communication. Results demonstrated a statistically significant improvement across all ATTITUDES subscales, while time management, role confusion, collaboration, and mutual support emerged as significant themes. Results of the present study indicate that a single IPE simulation event can reproducibly result in significant and educationally meaningful improvements in student perceptions towards teamwork, IPE, and simulation as a learning modality.

  20. Reliability assessments in qualitative health promotion research.

    Science.gov (United States)

    Cook, Kay E

    2012-03-01

    This article contributes to the debate about the use of reliability assessments in qualitative research in general, and health promotion research in particular. In this article, I examine the use of reliability assessments in qualitative health promotion research in response to health promotion researchers' commonly held misconception that reliability assessments improve the rigor of qualitative research. All qualitative articles published in the journal Health Promotion International from 2003 to 2009 employing reliability assessments were examined. In total, 31.3% (20/64) articles employed some form of reliability assessment. The use of reliability assessments increased over the study period, ranging from qualitative articles decreased. The articles were then classified into four types of reliability assessments, including the verification of thematic codes, the use of inter-rater reliability statistics, congruence in team coding and congruence in coding across sites. The merits of each type were discussed, with the subsequent discussion focusing on the deductive nature of reliable thematic coding, the limited depth of immediately verifiable data and the usefulness of such studies to health promotion and the advancement of the qualitative paradigm.

  1. Intra- and interrater reliability of the 'lumbar-locked thoracic rotation test' in competitive swimmers ages 10 through 18 years.

    Science.gov (United States)

    Feijen, Stef; Kuppens, Kevin; Tate, Angela; Baert, Isabel; Struyf, Thomas; Struyf, Filip

    2018-04-17

    Measuring thoracic spine mobility can be of interest to competitive swimmers as it has been associated with shoulder girdle function and scapular position in subjects with and without shoulder pain. At present, no reliability data of thoracic spine mobility measurements are available in the swimming population. This study aims to evaluate the within-session intra- and interrater reliability of the "lumbar-locked rotation test" for thoracic spine rotation in competitive swimmers aged 10 to 18 years. This reliability study is part of a larger prospective cohort study investigating potential risk factors for the development of shoulder pain in competitive swimmers. Within-session, intra- and inter-rater reliability. Competitive swimming clubs in Belgium. 21 competitive swimmers. Intra- and inter-rater reliability of the lumbar-locked thoracic rotation test. Intraclass correlation coefficients (ICCs) ranged from 0.91 (95% CI 0.78 to 0.96) to 0.96 (0.89-0.98) for intra-rater reliability. Results for inter-rater reliability ranged from 0.89 (0.72-0.95) to 0.86 (0.65-0.94) respectively for right and left thoracic rotation. Results suggest good to excellent reliability of the lumbar-locked thoracic rotation test, indicating this test can be used reliably in clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. RELIABILITY AND VALIDITY OF SUBJECTIVE ASSESSMENT OF LUMBAR LORDOSIS IN CONVENTIONAL RADIOGRAPHY.

    Science.gov (United States)

    Ruhinda, E; Byanyima, R K; Mugerwa, H

    2014-10-01

    Reliability and validity studies of different lumbar curvature analysis and measurement techniques have been documented however there is limited literature on the reliability and validity of subjective visual analysis. Radiological assessment of lumbar lordotic curve aids in early diagnosis of conditions even before neurologic changes set in. To ascertain the level of reliability and validity of subjective assessment of lumbar lordosis in conventional radiography. A blinded, repeated-measures diagnostic test was carried out on lumbar spine x-ray radiographs. Radiology Department at Joint Clinical Research Centre (JCRC), Mengo-Kampala-Uganda. Seventy (70) lateral lumbar x-ray films were used for this study and were obtained from the archive of JCRC radiology department at Butikiro house, Mengo-Kampala. Poor observer agreement, both inter- and intra-observer, with kappa values of 0.16 was found. Inter-observer agreement was poorer than intra-observer agreement. Kappa values significantly rose when the lumbar lordosis was clustered into four categories without grading each abnormality. The results confirm that subjective assessment of lumbar lordosis has low reliability and validity. Film quality has limited influence on the observer reliability. This study further shows that fewer scale categories of lordosis abnormalities produce better observer reliability.

  3. Revisiting the online health information reliability debate in the wake of "web 2.0": an inter-disciplinary literature and website review.

    Science.gov (United States)

    Adams, Samantha A

    2010-06-01

    The purpose of this inter-disciplinary literature review was to explore renewed concerns about the reliability of online health information in light of the increasing popularity of web applications that enable more end-user-generated content ("web 2.0"). The findings are based on a literature and web review. Literature was collected at four different points between October 2006 and October 2008 and included 56 sources from 10 academic disciplines. The web review consisted of following 6 blogs (including both new and archived posts, with comments) and one wiki for a period of 1.5 months and assessing the content for relevancy on six points, totaling 63 sources altogether. The reliability issues that are identified with respect to "web 2.0" reiterate more general concerns expressed about the web over the last 15 years. The difference, however, lies in the scope and scale of potential problems. Social scientists have also pointed to new issues that can be especially relevant for use of web 2.0 applications in health care. Specific points of renewed concern include: disclosure of authorship and information quality, anonymity and privacy, and the ability of individuals to apply information to their personal situation. Whether or not end-users understand what social scientists call "negative network externalities" is a new concern. Finally, not all reliability issues are negative-social networking and the shift from text-based information to symbolic information, images or interactive information, are considered to enhance patient education and to provide opportunities to reach diverse groups of patients. Interactive and collaborative web applications undeniably offer new opportunities for reaching patients and other health care consumers by facilitating lay information creation, sharing and retrieval. However, researchers must be careful and critical when incorporating applications or practices from other fields in health care. We must not easily dismiss concerns about

  4. Validating the JobFit system functional assessment method

    Energy Technology Data Exchange (ETDEWEB)

    Jenny Legge; Robin Burgess-Limerick

    2007-05-15

    Workplace injuries are costing the Australian coal mining industry and its communities $410 Million a year. This ACARP study aims to meet those demands by developing a safe, reliable and valid pre-employment functional assessment tool. All JobFit System Pre-Employment Functional Assessments (PEFAs) consist of a musculoskeletal screen, balance test, aerobic fitness test and job-specific postural tolerances and material handling tasks. The results of each component are compared to the applicant's job demands and an overall PEFA score between 1 and 4 is given with 1 being the better score. The reliability study and validity study were conducted concurrently. The reliability study examined test-retest, intra-tester and inter-tester reliability of the JobFit System Functional Assessment Method. Overall, good to excellent reliability was found, which was sufficient to be used for comparison with injury data for determining the validity of the assessment. The overall assessment score and material handling tasks had the greatest reliability. The validity study compared the assessment results of 336 records from a Queensland underground and open cut coal mine with their injury records. A predictive relationship was found between PEFA score and the risk of a back/trunk/shoulder injury from manual handling. An association was also found between PEFA score of 1 and increased length of employment. Lower aerobic fitness test results had an inverse relationship with injury rates. The study found that underground workers, regardless of PEFA score, were more likely to have an injury when compared to other departments. No relationship was found between age and risk of injury. These results confirm the validity of the JobFit System Functional Assessment method.

  5. Development of a quality-assessment tool for experimental bruxism studies: reliability and validity.

    Science.gov (United States)

    Dawson, Andreas; Raphael, Karen G; Glaros, Alan; Axelsson, Susanna; Arima, Taro; Ernberg, Malin; Farella, Mauro; Lobbezoo, Frank; Manfredini, Daniele; Michelotti, Ambra; Svensson, Peter; List, Thomas

    2013-01-01

    To combine empirical evidence and expert opinion in a formal consensus method in order to develop a quality-assessment tool for experimental bruxism studies in systematic reviews. Tool development comprised five steps: (1) preliminary decisions, (2) item generation, (3) face-validity assessment, (4) reliability and discriminitive validity assessment, and (5) instrument refinement. The kappa value and phi-coefficient were calculated to assess inter-observer reliability and discriminative ability, respectively. Following preliminary decisions and a literature review, a list of 52 items to be considered for inclusion in the tool was compiled. Eleven experts were invited to join a Delphi panel and 10 accepted. Four Delphi rounds reduced the preliminary tool-Quality-Assessment Tool for Experimental Bruxism Studies (Qu-ATEBS)- to 8 items: study aim, study sample, control condition or group, study design, experimental bruxism task, statistics, interpretation of results, and conflict of interest statement. Consensus among the Delphi panelists yielded good face validity. Inter-observer reliability was acceptable (k = 0.77). Discriminative validity was excellent (phi coefficient 1.0; P reviews of experimental bruxism studies, exhibits face validity, excellent discriminative validity, and acceptable inter-observer reliability. Development of quality assessment tools for many other topics in the orofacial pain literature is needed and may follow the described procedure.

  6. Performance and reliability of TPE-2 device with pulsed high power source

    International Nuclear Information System (INIS)

    Sato, Y.; Takeda, S.; Kiyama, S.

    1987-01-01

    The performance and the reliability of TPE-2 device with pulsed high power sources are described. To obtain the stable high beta plasma, the reproducibility and the reliability of the pulsed power sources must be maintained. A new power crowbar system with high efficiency and the switches with low jitter time are adopted to the bank system. A monitor system which always watches the operational states of the switches is developed too, and applied for the fast rising capacitor banks of TPE-2 device. The reliable operation for the bank has been realized, based on the data of switch monitor system

  7. High reliability low jitter 80 kV pulse generator

    Directory of Open Access Journals (Sweden)

    M. E. Savage

    2009-08-01

    Full Text Available Switching can be considered to be the essence of pulsed power. Time accurate switch/trigger systems with low inductance are useful in many applications. This article describes a unique switch geometry coupled with a low-inductance capacitive energy store. The system provides a fast-rising high voltage pulse into a low impedance load. It can be challenging to generate high voltage (more than 50 kilovolts into impedances less than 10  Ω, from a low voltage control signal with a fast rise time and high temporal accuracy. The required power amplification is large, and is usually accomplished with multiple stages. The multiple stages can adversely affect the temporal accuracy and the reliability of the system. In the present application, a highly reliable and low jitter trigger generator was required for the Z pulsed-power facility [M. E. Savage, L. F. Bennett, D. E. Bliss, W. T. Clark, R. S. Coats,J. M. Elizondo, K. R. LeChien, H. C. Harjes, J. M. Lehr, J. E. Maenchen, D. H. McDaniel, M. F. Pasik, T. D. Pointon, A. C. Owen, D. B. Seidel, D. L. Smith, B. S. Stoltzfus, K. W. Struve, W. A. Stygar, L. K. Warne, and J. R. Woodworth, 2007 IEEE Pulsed Power Conference, Albuquerque, NM (IEEE, Piscataway, NJ, 2007, p. 979]. The large investment in each Z experiment demands low prefire probability and low jitter simultaneously. The system described here is based on a 100 kV DC-charged high-pressure spark gap, triggered with an ultraviolet laser. The system uses a single optical path for simultaneously triggering two parallel switches, allowing lower inductance and electrode erosion with a simple optical system. Performance of the system includes 6 ns output rise time into 5.6  Ω, 550 ps one-sigma jitter measured from the 5 V trigger to the high voltage output, and misfire probability less than 10^{-4}. The design of the system and some key measurements will be shown in the paper. We will discuss the

  8. Reliability of widefield capillary microscopy to measure nailfold capillary density in systemic sclerosis.

    Science.gov (United States)

    Hudson, M; Masetto, A; Steele, R; Arthurs, E; Baron, M

    2010-01-01

    To determine intra- and inter-observer reliability of widefield microscopy to measure nailfold capillary density in patients with systemic sclerosis (SSc). Five SSc patients were examined with a STEMV-8 Zeiss biomicroscope with 50x magnification. The nailfold of the second, third, fourth and fifth fingers of both hands of each patient were photographed twice by each of two observers, once in the morning and again in the afternoon (total of 32 pictures). Two raters reviewed the photographs to produce capillary density readings. Intra- and inter-rater reliability of the readings were computed using intra-class correlations (ICC). Additional analyses were undertaken to determine the impact of other sources of variability in the data, namely patient, finger, technician and time. Intra-and inter-rater reliability were substantial (ICC 0.72-0.84) when raters were reading the same photographs or photographs taken at the same time of day. Agreement was only fair between morning and afternoon density readings (ICC 0.30-0.37). Patients, individual fingers and technician accounted for a large part of the variability in the data (combined variance component of 7.69 out of the total 12.23). The coefficient of variation of widefield microscopy was 24%. Although intra- and inter-rater reliability of nailfold capillary density measurements using widefield microscopy are good, proper standardisation of the conditions under which capillaroscopy is done and better imaging of nailfold capillary abnormalities should be considered if nailfold capillary density is to be used as an outcome measure in multi-centre clinical trials in SSc.

  9. Validity and inter-observer reliability of subjective hand-arm vibration assessments

    NARCIS (Netherlands)

    Coenen, P.; Formanoy, M.; Douwes, M.; Bosch, T.; Kraker, H. de

    2014-01-01

    Exposure to mechanical vibrations at work (e.g., due to handling powered tools) is a potential occupational risk as it may cause upper extremity complaints. However, reliable and valid assessment methods for vibration exposure at work are lacking. Measuring hand-arm vibration objectively is often

  10. The reliability of the Adelaide in-shoe foot model.

    Science.gov (United States)

    Bishop, Chris; Hillier, Susan; Thewlis, Dominic

    2017-07-01

    Understanding the biomechanics of the foot is essential for many areas of research and clinical practice such as orthotic interventions and footwear development. Despite the widespread attention paid to the biomechanics of the foot during gait, what largely remains unknown is how the foot moves inside the shoe. This study investigated the reliability of the Adelaide In-Shoe Foot Model, which was designed to quantify in-shoe foot kinematics and kinetics during walking. Intra-rater reliability was assessed in 30 participants over five walking trials whilst wearing shoes during two data collection sessions, separated by one week. Sufficient reliability for use was interpreted as a coefficient of multiple correlation and intra-class correlation coefficient of >0.61. Inter-rater reliability was investigated separately in a second sample of 10 adults by two researchers with experience in applying markers for the purpose of motion analysis. The results indicated good consistency in waveform estimation for most kinematic and kinetic data, as well as good inter-and intra-rater reliability. The exception is the peak medial ground reaction force, the minimum abduction angle and the peak abduction/adduction external hindfoot joint moments which resulted in less than acceptable repeatability. Based on our results, the Adelaide in-shoe foot model can be used with confidence for 24 commonly measured biomechanical variables during shod walking. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Highly reliable TOFD UT Technique

    International Nuclear Information System (INIS)

    Acharya, G.D.; Trivedi, S.A.R.; Pai, K.B.

    2003-01-01

    The high performance of the time of flight diffraction technique (TOFD) with regard to the detection capabilities of weld defects such as crack, slag, lack of fusion has led to a rapidly increasing acceptance of the technique as a pre?service inspection tool. Since the early 1990s TOFD has been applied to several projects, where it replaced the commonly used radiographic testing. The use of TOM lead to major time savings during new build and replacement projects. At the same time the TOFD technique was used as base line inspection, which enables monitoring in the future for critical welds, but also provides documented evidence for life?time. The TOFD technique as the ability to detect and simultaneously size flows of nearly any orientation within the weld and heat affected zone. TOM is recognized as a reliable, proven technique for detection and sizing of defects and proven to be a time saver, resulting in shorter shutdown periods and construction project times. Thus even in cases where inspection price of TOFD per welds is higher, in the end it will result in significantly lower overall costs and improve quality. This paper deals with reliability, economy, acceptance criteria and field experience. It also covers comparative study between radiography technique Vs. TOFD. (Author)

  12. Inter-observer agreement for diagnostic classification of esophageal motility disorders defined in high-resolution manometry

    NARCIS (Netherlands)

    Fox, M. R.; Pandolfino, J. E.; Sweis, R.; Sauter, M.; Abreu Y Abreu, A. T.; Anggiansah, A.; Bogte, A.; Bredenoord, A. J.; Dengler, W.; Elvevi, A.; Fruehauf, H.; Gellersen, S.; Ghosh, S.; Gyawali, C. P.; Heinrich, H.; Hemmink, M.; Jafari, J.; Kaufman, E.; Kessing, K.; Kwiatek, M.; Lubomyr, B.; Banasiuk, M.; Mion, F.; Pérez-de-la-Serna, J.; Remes-Troche, J. M.; Rohof, W.; Roman, S.; Ruiz-de-León, A.; Tutuian, R.; Uscinowicz, M.; Valdovinos, M. A.; Vardar, R.; Velosa, M.; Waśko-Czopnik, D.; Weijenborg, P.; Wilshire, C.; Wright, J.; Zerbib, F.; Menne, D.

    2015-01-01

    High-resolution esophageal manometry (HRM) is a recent development used in the evaluation of esophageal function. Our aim was to assess the inter-observer agreement for diagnosis of esophageal motility disorders using this technology. Practitioners registered on the HRM Working Group website were

  13. Reliability of the Alzheimer's disease assessment scale (ADAS-Cog) in longitudinal studies.

    Science.gov (United States)

    Khan, Anzalee; Yavorsky, Christian; DiClemente, Guillermo; Opler, Mark; Liechti, Stacy; Rothman, Brian; Jovic, Sofija

    2013-11-01

    Considering the scarcity of longitudinal assessments of reliability, there is need for a more precise understanding of cognitive decline in Alzheimer's Disease (AD). The primary goal was to assess longitudinal changes in inter-rater reliability, test retest reliability and internal consistency of scores of the ADAS-Cog. 2,618 AD subjects were enrolled in seven randomized, double-blind, placebo-controlled, multicenter-trials from 1986 to 2009. Reliability, internal-consistency and cross-sectional analysis of ADAS-Cog and MMSE across seven visits were examined. Intra-class correlation (ICC) for ADAS-Cog was moderate to high supporting their reliability. Absolute Agreement ICCs 0.392 (Visit-7) to 0.806 (Visit-2) showed a progressive decrease in correlations across time. Item analysis revealed a decrease in item correlations, with the lowest correlations for Visit 7 for Commands (ICC=0.148), Comprehension (ICC=0.092), Spoken Language (ICC=0.044). Suitable assessment of AD treatments is maintained through accurate measurement of clinically significant outcomes. Targeted rater education ADAS-Cog items over-time can improve ability to administer and score the scale.

  14. Seeking high reliability in primary care: Leadership, tools, and organization.

    Science.gov (United States)

    Weaver, Robert R

    2015-01-01

    Leaders in health care increasingly recognize that improving health care quality and safety requires developing an organizational culture that fosters high reliability and continuous process improvement. For various reasons, a reliability-seeking culture is lacking in most health care settings. Developing a reliability-seeking culture requires leaders' sustained commitment to reliability principles using key mechanisms to embed those principles widely in the organization. The aim of this study was to examine how key mechanisms used by a primary care practice (PCP) might foster a reliability-seeking, system-oriented organizational culture. A case study approach was used to investigate the PCP's reliability culture. The study examined four cultural artifacts used to embed reliability-seeking principles across the organization: leadership statements, decision support tools, and two organizational processes. To decipher their effects on reliability, the study relied on observations of work patterns and the tools' use, interactions during morning huddles and process improvement meetings, interviews with clinical and office staff, and a "collective mindfulness" questionnaire. The five reliability principles framed the data analysis. Leadership statements articulated principles that oriented the PCP toward a reliability-seeking culture of care. Reliability principles became embedded in the everyday discourse and actions through the use of "problem knowledge coupler" decision support tools and daily "huddles." Practitioners and staff were encouraged to report unexpected events or close calls that arose and which often initiated a formal "process change" used to adjust routines and prevent adverse events from recurring. Activities that foster reliable patient care became part of the taken-for-granted routine at the PCP. The analysis illustrates the role leadership, tools, and organizational processes play in developing and embedding a reliable-seeking culture across an

  15. Reliability of segmental accelerations measured using a new wireless gait analysis system.

    Science.gov (United States)

    Kavanagh, Justin J; Morrison, Steven; James, Daniel A; Barrett, Rod

    2006-01-01

    The purpose of this study was to determine the inter- and intra-examiner reliability, and stride-to-stride reliability, of an accelerometer-based gait analysis system which measured 3D accelerations of the upper and lower body during self-selected slow, preferred and fast walking speeds. Eight subjects attended two testing sessions in which accelerometers were attached to the head, neck, lower trunk, and right shank. In the initial testing session, two different examiners attached the accelerometers and performed the same testing procedures. A single examiner repeated the procedure in a subsequent testing session. All data were collected using a new wireless gait analysis system, which features near real-time data transmission via a Bluetooth network. Reliability for each testing condition (4 locations, 3 directions, 3 speeds) was quantified using a waveform similarity statistic known as the coefficient of multiple determination (CMD). CMD's ranged from 0.60 to 0.98 across all test conditions and were not significantly different for inter-examiner (0.86), intra-examiner (0.87), and stride-to-stride reliability (0.86). The highest repeatability for the effect of location, direction and walking speed were for the shank segment (0.94), the vertical direction (0.91) and the fast walking speed (0.91), respectively. Overall, these results indicate that a high degree of waveform repeatability was obtained using a new gait system under test-retest conditions involving single and dual examiners. Furthermore, differences in acceleration waveform repeatability associated with the reapplication of accelerometers were small in relation to normal motor variability.

  16. Assessing the environmental characteristics of cycling routes to school: a study on the reliability and validity of a Google Street View-based audit.

    Science.gov (United States)

    Vanwolleghem, Griet; Van Dyck, Delfien; Ducheyne, Fabian; De Bourdeaudhuij, Ilse; Cardon, Greet

    2014-06-10

    Google Street View provides a valuable and efficient alternative to observe the physical environment compared to on-site fieldwork. However, studies on the use, reliability and validity of Google Street View in a cycling-to-school context are lacking. We aimed to study the intra-, inter-rater reliability and criterion validity of EGA-Cycling (Environmental Google Street View Based Audit - Cycling to school), a newly developed audit using Google Street View to assess the physical environment along cycling routes to school. Parents (n = 52) of 11-to-12-year old Flemish children, who mostly cycled to school, completed a questionnaire and identified their child's cycling route to school on a street map. Fifty cycling routes of 11-to-12-year olds were identified and physical environmental characteristics along the identified routes were rated with EGA-Cycling (5 subscales; 37 items), based on Google Street View. To assess reliability, two researchers performed the audit. Criterion validity of the audit was examined by comparing the ratings based on Google Street View with ratings through on-site assessments. Intra-rater reliability was high (kappa range 0.47-1.00). Large variations in the inter-rater reliability (kappa range -0.03-1.00) and criterion validity scores (kappa range -0.06-1.00) were reported, with acceptable inter-rater reliability values for 43% of all items and acceptable criterion validity for 54% of all items. EGA-Cycling can be used to assess physical environmental characteristics along cycling routes to school. However, to assess the micro-environment specifically related to cycling, on-site assessments have to be added.

  17. Improving patient safety: patient-focused, high-reliability team training.

    Science.gov (United States)

    McKeon, Leslie M; Cunningham, Patricia D; Oswaks, Jill S Detty

    2009-01-01

    Healthcare systems are recognizing "human factor" flaws that result in adverse outcomes. Nurses work around system failures, although increasing healthcare complexity makes this harder to do without risk of error. Aviation and military organizations achieve ultrasafe outcomes through high-reliability practice. We describe how reliability principles were used to teach nurses to improve patient safety at the front line of care. Outcomes include safety-oriented, teamwork communication competency; reflections on safety culture and clinical leadership are discussed.

  18. A High Reliability Frequency Stabilized Semiconductor Laser Source, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Ultrastable, narrow linewidth, high reliability MOPA sources are needed for high performance LIDARs in NASA for, wind speed measurement, surface topography and earth...

  19. Inter-rater reliability of the Greek version of CAARMS among two groups of mental health professionals.

    Science.gov (United States)

    Kollias, C; Kontaxakis, V; Havaki-Kontaxaki, B; Simmons, M B; Stefanis, N; Papageorgiou, C

    2015-01-01

    There is increasing interest within the Greek psychiatric community in the early detection and prevention of psychotic disorders. To support this, there is a need for a valid and reliable tool to identify young people that may be at risk of developing a psychotic disorder. Our team has previously translated the Comprehensive Assessment of At-Risk Mental States (CAARMS). The validity of the CAARMS was ensured by the procedure of translation and the aim of the current study was to estimate the interrater reliability of the CAARMS Greek translation among residents in psychiatry and specialized mental health professionals. 43 mental health workers (27 residents in psychiatry and 16 specialized mental health professionals (i.e. 11 psychiatrists and 5 psychologist) participated in two seminars that covered theoretical information about the ultra high risk concept and training in the CAARMS. During the seminars, 10 vignettes with psychiatric history cases were presented, including healthy, ultra high risk and first episode psychosis. The mean correlated percentage of agreement with the correct answers regarding diagnosis of the presented history cases among all our subjects was 81.42, among specialized mental health professionals 77.88, and among residents 84.46. Intraclass correlation co-efficients were 0.994 for specialized mental health professionals and 0.997 for residents. The translated Greek version of CAARMS presents a satisfying interrater reliability when used by both residents and specialized mental health professionals. Residents declare even higher intraclass correlation co-efficients and mean correlated percentage of agreement than specialized mental health professionals, which indicate that residents are capable of using the CAARMS in early intervention units.

  20. How reliable are case formulations? A systematic literature review.

    Science.gov (United States)

    Flinn, Lucinda; Braham, Louise; das Nair, Roshan

    2015-09-01

    This systematic literature review investigated the inter-rater and test-retest reliability of case formulations. We considered the reliability of case formulations across a range of theoretical modalities and the general quality of the primary research studies. A systematic search of five electronic databases was conducted in addition to reference list trawling to find studies that assessed the reliability of case formulation. This yielded 18 studies for review. A methodological quality assessment tool was developed to assess the quality of studies, which informed interpretation of the findings. Results indicated inter-rater reliability mainly ranging from slight (.1-.4) to substantial (.81-1.0). Some studies highlighted that training and increased experience led to higher levels of agreement. In general, psychodynamic formulations appeared to generate somewhat increased levels of reliability than cognitive or behavioural formulations; however, these studies also included methods that may have served to inflate reliability, for example, pooling the scores of judges. Only one study investigated the test-retest reliability of case formulations yielding support for the stability of formulations over a 3-month period. Reliability of case formulations is varied across a range of theoretical modalities, but can be improved; however, further research is required to strengthen our conclusions. Clinical implications: The findings from the review evidence some support for case formulation being congruent with the scientist-practitioner approach. The reliability of case formulation is likely to be improved through training and clinical experience. Limitations: The broad inclusion criteria may have introduced heterogeneity into the sample, which may have affected the results. Studies reviewed were limited to peer-reviewed journal articles written in the English language, which may represent a source of publication and selection bias. © 2014 The British Psychological Society.

  1. On the design of high-rise buildings with a specified level of reliability

    Science.gov (United States)

    Dolganov, Andrey; Kagan, Pavel

    2018-03-01

    High-rise buildings have a specificity, which significantly distinguishes them from traditional buildings of high-rise and multi-storey buildings. Steel structures in high-rise buildings are advisable to be used in earthquake-proof regions, since steel, due to its plasticity, provides damping of the kinetic energy of seismic impacts. These aspects should be taken into account when choosing a structural scheme of a high-rise building and designing load-bearing structures. Currently, modern regulatory documents do not quantify the reliability of structures. Although the problem of assigning an optimal level of reliability has existed for a long time. The article shows the possibility of designing metal structures of high-rise buildings with specified reliability. Currently, modern regulatory documents do not quantify the reliability of high-rise buildings. Although the problem of assigning an optimal level of reliability has existed for a long time. It is proposed to establish the value of reliability 0.99865 (3σ) for constructions of buildings and structures of a normal level of responsibility in calculations for the first group of limiting states. For increased (construction of high-rise buildings) and reduced levels of responsibility for the provision of load-bearing capacity, it is proposed to assign respectively 0.99997 (4σ) and 0.97725 (2σ). The coefficients of the use of the cross section of a metal beam for different levels of security are given.

  2. Reliability, construct and discriminative validity of clinical testing in subjects with and without chronic neck pain

    DEFF Research Database (Denmark)

    Jørgensen, René; Ris Hansen, Inge; Falla, Deborah

    2014-01-01

    -retest reliability in people with and without chronic neck pain. Moreover, construct and between-group discriminative validity of the tests were examined. METHODS: Twenty-one participants with chronic neck pain and 21 asymptomatic participants were included. Intra- and inter-reliability were evaluated for the Cranio-Cervical...... Flexion Test (CCFT), Range of Movement (ROM), Joint Position Error (JPE), Gaze Stability (GS), Smooth Pursuit Neck Torsion Test (SPNTT), and neuromuscular control of the Deep Cervical Extensors (DCE). Test-retest reliability was assessed for Postural Control (SWAY) and Pressure Pain Threshold (PPT) over......BACKGROUND: The reliability of clinical tests for the cervical spine has not been adequately evaluated. Six cervical clinical tests, which are low cost and easy to perform in clinical settings, were tested for intra- and inter-examiner reliability, and two performance tests were assessed for test...

  3. An objective spinal motion imaging assessment (OSMIA: reliability, accuracy and exposure data

    Directory of Open Access Journals (Sweden)

    Mellor Fiona E

    2006-01-01

    Full Text Available Abstract Background Minimally-invasive measurement of continuous inter-vertebral motion in clinical settings is difficult to achieve. This paper describes the reliability, validity and radiation exposure levels in a new Objective Spinal Motion Imaging Assessment system (OSMIA based on low-dose fluoroscopy and image processing. Methods Fluoroscopic sequences in coronal and sagittal planes were obtained from 2 calibration models using dry lumbar vertebrae, plus the lumbar spines of 30 asymptomatic volunteers. Calibration model 1 (mobile was screened upright, in 7 inter-vertebral positions. The volunteers and calibration model 2 (fixed were screened on a motorised table comprising 2 horizontal sections, one of which moved through 80 degrees. Model 2 was screened during motion 5 times and the L2-S1 levels of the volunteers twice. Images were digitised at 5fps. Inter-vertebral motion from model 1 was compared to its pre-settings to investigate accuracy. For volunteers and model 2, the first digitised image in each sequence was marked with templates. Vertebrae were tracked throughout the motion using automated frame-to-frame registration. For each frame, vertebral angles were subtracted giving inter-vertebral motion graphs. Volunteer data were acquired twice on the same day and analysed by two blinded observers. The root-mean-square (RMS differences between paired data were used as the measure of reliability. Results RMS difference between reference and computed inter-vertebral angles in model 1 was 0.32 degrees for side-bending and 0.52 degrees for flexion-extension. For model 2, X-ray positioning contributed more to the variance of range measurement than did automated registration. For volunteer image sequences, RMS inter-observer variation in intervertebral motion range in the coronal plane was 1.86 degreesand intra-subject biological variation was between 2.75 degrees and 2.91 degrees. RMS inter-observer variation in the sagittal plane was 1

  4. Reliability-based design optimization via high order response surface method

    International Nuclear Information System (INIS)

    Li, Hong Shuang

    2013-01-01

    To reduce the computational effort of reliability-based design optimization (RBDO), the response surface method (RSM) has been widely used to evaluate reliability constraints. We propose an efficient methodology for solving RBDO problems based on an improved high order response surface method (HORSM) that takes advantage of an efficient sampling method, Hermite polynomials and uncertainty contribution concept to construct a high order response surface function with cross terms for reliability analysis. The sampling method generates supporting points from Gauss-Hermite quadrature points, which can be used to approximate response surface function without cross terms, to identify the highest order of each random variable and to determine the significant variables connected with point estimate method. The cross terms between two significant random variables are added to the response surface function to improve the approximation accuracy. Integrating the nested strategy, the improved HORSM is explored in solving RBDO problems. Additionally, a sampling based reliability sensitivity analysis method is employed to reduce the computational effort further when design variables are distributional parameters of input random variables. The proposed methodology is applied on two test problems to validate its accuracy and efficiency. The proposed methodology is more efficient than first order reliability method based RBDO and Monte Carlo simulation based RBDO, and enables the use of RBDO as a practical design tool.

  5. Replicable Interprofessional Competency Outcomes from High-Volume, Inter-Institutional, Interprofessional Simulation

    Directory of Open Access Journals (Sweden)

    Deborah Bambini

    2016-10-01

    Full Text Available There are significant limitations among the few prior studies that have examined the development and implementation of interprofessional education (IPE experiences to accommodate a high volume of students from several disciplines and from different institutions. The present study addressed these gaps by seeking to determine the extent to which a single, large, inter-institutional, and IPE simulation event improves student perceptions of the importance and relevance of IPE and simulation as a learning modality, whether there is a difference in students’ perceptions among disciplines, and whether the results are reproducible. A total of 290 medical, nursing, pharmacy, and physical therapy students participated in one of two large, inter-institutional, IPE simulation events. Measurements included student perceptions about their simulation experience using the Attitude Towards Teamwork in Training Undergoing Designed Educational Simulation (ATTITUDES Questionnaire and open-ended questions related to teamwork and communication. Results demonstrated a statistically significant improvement across all ATTITUDES subscales, while time management, role confusion, collaboration, and mutual support emerged as significant themes. Results of the present study indicate that a single IPE simulation event can reproducibly result in significant and educationally meaningful improvements in student perceptions towards teamwork, IPE, and simulation as a learning modality.

  6. Reliability of specific physical examination tests for the diagnosis of shoulder pathologies: a systematic review and meta-analysis.

    Science.gov (United States)

    Lange, Toni; Matthijs, Omer; Jain, Nitin B; Schmitt, Jochen; Lützner, Jörg; Kopkow, Christian

    2017-03-01

    Shoulder pain in the general population is common and to identify the aetiology of shoulder pain, history, motion and muscle testing, and physical examination tests are usually performed. The aim of this systematic review was to summarise and evaluate intrarater and inter-rater reliability of physical examination tests in the diagnosis of shoulder pathologies. A comprehensive systematic literature search was conducted using MEDLINE, EMBASE, Allied and Complementary Medicine Database (AMED) and Physiotherapy Evidence Database (PEDro) through 20 March 2015. Methodological quality was assessed using the Quality Appraisal of Reliability Studies (QAREL) tool by 2 independent reviewers. The search strategy revealed 3259 articles, of which 18 finally met the inclusion criteria. These studies evaluated the reliability of 62 test and test variations used for the specific physical examination tests for the diagnosis of shoulder pathologies. Methodological quality ranged from 2 to 7 positive criteria of the 11 items of the QAREL tool. This review identified a lack of high-quality studies evaluating inter-rater as well as intrarater reliability of specific physical examination tests for the diagnosis of shoulder pathologies. In addition, reliability measures differed between included studies hindering proper cross-study comparisons. PROSPERO CRD42014009018. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. The reliability of a segmentation methodology for assessing intramuscular adipose tissue and other soft-tissue compartments of lower leg MRI images.

    Science.gov (United States)

    Karampatos, Sarah; Papaioannou, Alexandra; Beattie, Karen A; Maly, Monica R; Chan, Adrian; Adachi, Jonathan D; Pritchard, Janet M

    2016-04-01

    Determine the reliability of a magnetic resonance (MR) image segmentation protocol for quantifying intramuscular adipose tissue (IntraMAT), subcutaneous adipose tissue, total muscle and intermuscular adipose tissue (InterMAT) of the lower leg. Ten axial lower leg MRI slices were obtained from 21 postmenopausal women using a 1 Tesla peripheral MRI system. Images were analyzed using sliceOmatic™ software. The average cross-sectional areas of the tissues were computed for the ten slices. Intra-rater and inter-rater reliability were determined and expressed as the standard error of measurement (SEM) (absolute reliability) and intraclass coefficient (ICC) (relative reliability). Intra-rater and inter-rater reliability for IntraMAT were 0.991 (95% confidence interval [CI] 0.978-0.996, p soft tissue compartments, the ICCs were all >0.90 (p soft-tissue compartments of the lower leg. A standard operating procedure manual is provided to assist users, and SEM values can be used to estimate sample size and determine confidence in repeated measurements in future research.

  8. Reliability and validity of a tool to assess airway management skills in anesthesia trainees

    Directory of Open Access Journals (Sweden)

    Aliya Ahmed

    2016-01-01

    Conclusion: The tool designed to assess bag-mask ventilation and tracheal intubation skills in anesthesia trainees demonstrated excellent inter-rater reliability, fair test-retest reliability, and good construct validity. The authors recommend its use for formative and summative assessment of junior anesthesia trainees.

  9. Highly-reliable laser diodes and modules for spaceborne applications

    Science.gov (United States)

    Deichsel, E.

    2017-11-01

    Laser applications become more and more interesting in contemporary missions such as earth observations or optical communication in space. One of these applications is light detection and ranging (LIDAR), which comprises huge scientific potential in future missions. The Nd:YAG solid-state laser of such a LIDAR system is optically pumped using 808nm emitting pump sources based on semiconductor laser-diodes in quasi-continuous wave (qcw) operation. Therefore reliable and efficient laser diodes with increased output powers are an important requirement for a spaceborne LIDAR-system. In the past, many tests were performed regarding the performance and life-time of such laser-diodes. There were also studies for spaceborne applications, but a test with long operation times at high powers and statistical relevance is pending. Other applications, such as science packages (e.g. Raman-spectroscopy) on planetary rovers require also reliable high-power light sources. Typically fiber-coupled laser diode modules are used for such applications. Besides high reliability and life-time, designs compatible to the harsh environmental conditions must be taken in account. Mechanical loads, such as shock or strong vibration are expected due to take-off or landing procedures. Many temperature cycles with high change rates and differences must be taken in account due to sun-shadow effects in planetary orbits. Cosmic radiation has strong impact on optical components and must also be taken in account. Last, a hermetic sealing must be considered, since vacuum can have disadvantageous effects on optoelectronics components.

  10. Reliability and Validity of the Dutch Physical Activity Questionnaires for Children (PAQ-C) and Adolescents (PAQ-A).

    Science.gov (United States)

    Bervoets, Liene; Van Noten, Caroline; Van Roosbroeck, Sofie; Hansen, Dominique; Van Hoorenbeeck, Kim; Verheyen, Els; Van Hal, Guido; Vankerckhoven, Vanessa

    2014-01-01

    This study was designed to validate the Dutch Physical Activity Questionnaires for Children (PAQ-C) and Adolescents (PAQ-A). After adjustment of the original Canadian PAQ-C and PAQ-A (i.e. translation/back-translation and evaluation by expert committee), content validity of both PAQs was assessed and calculated using item-level (I-CVI) and scale-level (S-CVI) content validity indexes. Inter-item and inter-rater reliability of 196 PAQ-C and 95 PAQ-A filled in by both children or adolescents and their parent, were evaluated. Inter-item reliability was calculated by Cronbach's alpha (α) and inter-rater reliability was examined by percent observed agreement and weighted kappa (κ). Concurrent validity of PAQ-A was examined in a subsample of 28 obese and 16 normal-weight children by comparing it with concurrently measured physical activity using a maximal cardiopulmonary exercise test for the assessment of peak oxygen uptake (VO2 peak). For both PAQs, I-CVI ranged 0.67-1.00. S-CVI was 0.89 for PAQ-C and 0.90 for PAQ-A. A total of 192 PAQ-C and 94 PAQ-A were fully completed by both child and parent. Cronbach's α was 0.777 for PAQ-C and 0.758 for PAQ-A. Percent agreement ranged 59.9-74.0% for PAQ-C and 51.1-77.7% for PAQ-A, and weighted κ ranged 0.48-0.69 for PAQ-C and 0.51-0.68 for PAQ-A. The correlation between total PAQ-A score and VO2 peak - corrected for age, gender, height and weight - was 0.516 (p = 0.001). Both PAQs have an excellent content validity, an acceptable inter-item reliability and a moderate to good strength of inter-rater agreement. In addition, total PAQ-A score showed a moderate positive correlation with VO2 peak. Both PAQs have an acceptable to good reliability and validity, however, further validity testing is recommended to provide a more complete assessment of both PAQs.

  11. Utilizing leadership to achieve high reliability in the delivery of perinatal care

    Directory of Open Access Journals (Sweden)

    Parrotta C

    2012-11-01

    Full Text Available Carmen Parrotta,1 William Riley,1 Les Meredith21School of Public Health, University of Minnesota, Minneapolis, MN, 2Premier Insurance Management Services Inc, Charlotte, NC, USAAbstract: Highly reliable care requires standardization of clinical practices and is a prerequisite for patient safety. However, standardization in complex hospital settings is extremely difficult to attain and health care leaders are challenged to create care delivery processes that ensure patient safety. Moreover, once high reliability is achieved in a hospital unit, it must be maintained to avoid process deterioration. This case study examines an intervention to implement care bundles (a collection of evidence-based practices in four hospitals to achieve standardized care in perinatal units. The results show different patterns in the rate and magnitude of change within the hospitals to achieve high reliability. The study is part of a larger nationwide study of 16 hospitals to improve perinatal safety. Based on the findings, we discuss the role of leadership for implementing and sustaining high reliability to ensure freedom from unintended injury.Keywords: care bundles, evidence-based practice, standardized care, process improvement

  12. To the problem of reliability of high-voltage accelerators for industrial purposes

    International Nuclear Information System (INIS)

    Al'bertinskij, B.I.; Svin'in, M.P.; Tsepakin, S.G.

    1979-01-01

    Statistical data characterizing the reliability of ELECTRON and AVRORA-2 type accelerators are presented. Used as a reliability index was the mean time to failure of the main accelerator units. The analysis of accelerator failures allowed a number of conclusions to be drawn. The high failure rate level is connected with inadequate training of the servicing personnel and a natural period of equipment adjustment. The mathematical analysis of the failure rate showed that the main responsibility for insufficient high reliability rests with selenium diodes which are employed in the high voltage power supply. Substitution of selenium diodes by silicon ones increases time between failures. It is shown that accumulation and processing of operational statistical data will permit more accurate prediction of the reliability of produced high-voltage accelerators, make it possible to cope with the problems of planning optimal, in time, preventive inspections and repair, and to select optimal safety factors and test procedures n time, preventive inspections and repair, and to select optimal safety factors and test procedures n time, prevent

  13. Reliability of high power electron accelerators for radiation processing

    Energy Technology Data Exchange (ETDEWEB)

    Zimek, Z. [Department of Radiation Chemistry and Technology, Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    2011-07-01

    Accelerators applied for radiation processing are installed in industrial facilities where accelerator availability coefficient should be at the level of 95% to fulfill requirements according to industry standards. Usually the exploitation of electron accelerator reviles the number of short and few long lasting failures. Some technical shortages can be overcome by practical implementation the experience gained in accelerator technology development by different accelerator manufactures. The reliability/availability of high power accelerators for application in flue gas treatment process must be dramatically improved to meet industrial standards. Support of accelerator technology dedicated for environment protection should be provided by governmental and international institutions to overcome accelerator reliability/availability problem and high risk and low direct profit in this particular application. (author)

  14. Reliability of high power electron accelerators for radiation processing

    International Nuclear Information System (INIS)

    Zimek, Z.

    2011-01-01

    Accelerators applied for radiation processing are installed in industrial facilities where accelerator availability coefficient should be at the level of 95% to fulfill requirements according to industry standards. Usually the exploitation of electron accelerator reviles the number of short and few long lasting failures. Some technical shortages can be overcome by practical implementation the experience gained in accelerator technology development by different accelerator manufactures. The reliability/availability of high power accelerators for application in flue gas treatment process must be dramatically improved to meet industrial standards. Support of accelerator technology dedicated for environment protection should be provided by governmental and international institutions to overcome accelerator reliability/availability problem and high risk and low direct profit in this particular application. (author)

  15. Analysis and recommendations for a reliable programming of software based safety systems

    International Nuclear Information System (INIS)

    Nunez McLeod, J.; Nunez McLeod, J.E.; Rivera, S.S.

    1997-01-01

    The present paper summarizes the results of several studies performed for the development of high software on i486 microprocessors, towards its utilization for control and safety systems for nuclear power plants. The work is based on software programmed in C language. Several recommendations oriented to high reliability software are analyzed, relating the requirements on high level language to its influence on assembler level. Several metrics are implemented, that allow for the quantification of the results achieved. New metrics were developed and other were adapted, in order to obtain more efficient indexes for the software description. Such metrics are helpful to visualize the adaptation of the software under development to the quality rules under use. A specific program developed to assist the reliability analyst on this quantification is also present in the paper. It performs the analysis of an executable program written in C language, disassembling it and evaluating its inter al structures. (author)

  16. Validity and inter-rater reliability of medio-lateral knee motion observed during a single-limb mini squat

    Directory of Open Access Journals (Sweden)

    Simic Milena

    2010-11-01

    Full Text Available Abstract Background Muscle function may influence the risk of knee injury and outcomes following injury. Clinical tests, such as a single-limb mini squat, resemble conditions of daily life and are easy to administer. Fewer squats per 30 seconds indicate poorer function. However, the quality of movement, such as the medio-lateral knee motion may also be important. The aim was to validate an observational clinical test of assessing the medio-lateral knee motion, using a three-dimensional (3-D motion analysis system. In addition, the inter-rater reliability was evaluated. Methods Twenty-five (17 women non-injured participants (mean age 25.6 years, range 18-37 were included. Visual analysis of the medio-lateral knee motion, scored as knee-over-foot or knee-medial-to-foot by two raters, and 3-D kinematic data were collected simultaneously during a single-limb mini squat. Frontal plane 2-D peak tibial, thigh, and knee varus-valgus angles, and 3-D peak hip internal-external rotation, and knee varus-valgus angles were calculated. Results Ten subjects were scored as having a knee-medial-to-foot position and 15 subjects a knee-over-foot position assessed by visual inspection. In 2-D, the peak tibial angle (mean 89.0 (SE 0.7 vs mean 86.3 (SE 0.4 degrees, p = 0.001 and peak thigh angle (mean 77.4 (SE 1.0 vs mean 81.2 (SE 0.5 degrees, p = 0.001 with respect to the horizontal, indicated that the knee was more medially placed than the ankle and thigh, respectively. Thus, the knee was in more valgus (mean 11.6 (SE 1.5 vs 5.0 (SE 0.8 degrees, p 0.90 and 96 between raters. Conclusions Medio-lateral motion of the knee can reliably be assessed during a single-leg mini-squat. The test is valid in 2-D, while the actual movement, in 3-D, is mainly exhibited as increased internal hip rotation. The single-limb mini squat is feasible and easy to administer in the clinical setting and in research to address lower extremity movement quality.

  17. Reliability and validity of the Turkish version of the Berg Balance Scale.

    Science.gov (United States)

    Sahin, Fusun; Yilmaz, Figen; Ozmaden, Asli; Kotevolu, Nurdan; Sahin, Tulay; Kuran, Banu

    2008-01-01

    The purpose of this study was to develop a Turkish version of the Berg Balance Scale (BBS) and assess its reliability and validity. Sixty healthy volunteers older than 65 years were included in to the study. Subjects who had lower extremity amputation, or were armchair or bedridden were excluded. After translation process, the Turkish version of the scale was administered to each participant twice with an interval of 2 weeks. The intraclass correlation coefficient (ICC) was calculated to assess intra- and inter-observer reliability. Chronbach alpha was calculated to evaluate internal consistency of the total BBS score. Interclass correlation coefficient was calcuated to examine test-retest reliability. Convergent validity was assessed by correlating the scale with Modified Barthel Index (MBI) and Timed Up and Go Test (TUG). Construct validity was assessed with factor analysis. The mean age in years of the participants were 77.00+/-5.67 (range: 67-92 yrs). The ICC for intra- and inter- observer reliability was 0.98 (pr=0.67 pr=-0.75 p<0.0001, respectively). The Turkish version of the BBS is a reliable and valid scale to be used in balance assessment of Turkish older adults.

  18. Telepsychiatry clinical decision support system used by non-psychiatrists in remote areas: Validity & reliability of diagnostic module

    Science.gov (United States)

    Malhotra, Savita; Chakrabarti, Subho; Shah, Ruchita; Sharma, Minali; Sharma, Kanu Priya; Malhotra, Akanksha; Upadhyaya, Suneet K.; Margoob, Mushtaq A.; Maqbool, Dar; Jassal, Gopal D.

    2017-01-01

    Background & objectives: A knowledge-based, logically-linked online telepsychiatric decision support system for diagnosis and treatment of mental disorders was developed and validated. We evaluated diagnostic accuracy and reliability of the application at remote sites when used by non-psychiatrists who underwent a brief training in its use through video-conferencing. Methods: The study was conducted at a nodal telepsychiatry centre, and three geographically remote peripheral centres. The diagnostic tool of application had a screening followed by detailed criteria-wise diagnostic modules for 18 psychiatric disorders. A total of 100 consecutive consenting adult outpatients attending remote telepsychiatry centres were included. To assess inter-rater reliability, patients were interviewed face to face by non-specialists at remote sites using the application (active interviewer) and simultaneously on online application via video-conferencing by a passive assessor at nodal centre. Another interviewer at the nodal centre rated the patient using Mini-International Neuropsychiatric Interview (MINI) for diagnostic validation. Results: Screening sub-module had high sensitivity (80-100%), low positive predictive values (PPV) (0.10-0.71) but high negative predictive value (NPV) (0.97-1) for most disorders. For the diagnostic sub-modules, Cohen's kappa was >0.4 for all disorders, with kappa of 0.7-1.0 for most disorders. PPV and NPV were high for most disorders. Inter-rater agreement analysis revealed kappa >0.6 for all disorders. Interpretation & conclusions: Diagnostic tool showed acceptable to good validity and reliability when used by non-specialists at remote sites. Our findings show that diagnostic tool of the telepsychiatry application has potential to empower non-psychiatrist doctors and paramedics to diagnose psychiatric disorders accurately and reliably in remote sites. PMID:29265020

  19. High-reliability, 4. pi. -scan, leakage-x-ray dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, T; Iida, H; Yoshida, T; Sugimoto, H [Tokyo Shibaura Electric Co. Ltd., Kawasaki, Kanagawa (Japan). Tamagawa Works

    1978-04-01

    A world-wide movement is growing for the protection of living bodies against leakage radiations. In Japan, detailed regulations have been established for the enforcement of the law in regard to this problem. The substances of the measurement provided in the regulations are extremely diversified, much affecting the reliability and the economic efficiency of the equipment. Now a new 4..pi..-scan X-ray dosimeter with high reliability has been developed and proved to effect qualitative improvement of measurement as well as elevation of productivity.

  20. Modeling high-Power Accelerators Reliability-SNS LINAC (SNS-ORNL); MAX LINAC (MYRRHA)

    International Nuclear Information System (INIS)

    Pitigoi, A. E.; Fernandez Ramos, P.

    2013-01-01

    Improving reliability has recently become a very important objective in the field of particle accelerators. The particle accelerators in operation are constantly undergoing modifications, and improvements are implemented using new technologies, more reliable components or redundant schemes (to obtain more reliability, strength, more power, etc.) A reliability model of SNS (Spallation Neutron Source) LINAC has been developed within MAX project and analysis of the accelerator systems reliability has been performed within the MAX project, using the Risk Spectrum reliability analysis software. The analysis results have been evaluated by comparison with the SNS operational data. Results and conclusions are presented in this paper, oriented to identify design weaknesses and provide recommendations for improving reliability of MYRRHA linear accelerator. The SNS reliability model developed for the MAX preliminary design phase indicates possible avenues for further investigation that could be needed to improve the reliability of the high-power accelerators, in view of the future reliability targets of ADS accelerators.

  1. Rater reliability and construct validity of a mobile application for posture analysis.

    Science.gov (United States)

    Szucs, Kimberly A; Brown, Elena V Donoso

    2018-01-01

    [Purpose] Measurement of posture is important for those with a clinical diagnosis as well as researchers aiming to understand the impact of faulty postures on the development of musculoskeletal disorders. A reliable, cost-effective and low tech posture measure may be beneficial for research and clinical applications. The purpose of this study was to determine rater reliability and construct validity of a posture screening mobile application in healthy young adults. [Subjects and Methods] Pictures of subjects were taken in three standing positions. Two raters independently digitized the static standing posture image twice. The app calculated posture variables, including sagittal and coronal plane translations and angulations. Intra- and inter-rater reliability were calculated using the appropriate ICC models for complete agreement. Construct validity was determined through comparison of known groups using repeated measures ANOVA. [Results] Intra-rater reliability ranged from 0.71 to 0.99. Inter-rater reliability was good to excellent for all translations. ICCs were stronger for translations versus angulations. The construct validity analysis found that the app was able to detect the change in the four variables selected. [Conclusion] The posture mobile application has demonstrated strong rater reliability and preliminary evidence of construct validity. This application may have utility in clinical and research settings.

  2. Validity and Reliability of the Academic Resilience Scale in Turkish High School

    Science.gov (United States)

    Kapikiran, Sahin

    2012-01-01

    The present study aims to determine the validity and reliability of the academic resilience scale in Turkish high school. The participances of the study includes 378 high school students in total (192 female and 186 male). A set of analyses were conducted in order to determine the validity and reliability of the study. Firstly, both exploratory…

  3. Reliability of sonographic assessment of tendinopathy in tennis elbow.

    Science.gov (United States)

    Poltawski, Leon; Ali, Syed; Jayaram, Vijay; Watson, Tim

    2012-01-01

    To assess the reliability and compute the minimum detectable change using sonographic scales to quantify the extent of pathology and hyperaemia in the common extensor tendon in people with tennis elbow. The lateral elbows of 19 people with tennis elbow were assessed sonographically twice, 1-2 weeks apart. Greyscale and power Doppler images were recorded for subsequent rating of abnormalities. Tendon thickening, hypoechogenicity, fibrillar disruption and calcification were each rated on four-point scales, and scores were summed to provide an overall rating of structural abnormality; hyperaemia was scored on a five point scale. Inter-rater reliability was established using the intraclass correlation coefficient (ICC) to compare scores assigned independently to the same set of images by a radiologist and a physiotherapist with training in musculoskeletal imaging. Test-retest reliability was assessed by comparing scores assigned by the physiotherapist to images recorded at the two sessions. The minimum detectable change (MDC) was calculated from the test-retest reliability data. ICC values for inter-rater reliability ranged from 0.35 (95% CI: 0.05, 0.60) for fibrillar disruption to 0.77 (0.55, 0.88) for overall greyscale score, and 0.89 (0.79, 0.95) for hyperaemia. Test-retest reliability ranged from 0.70 (0.48, 0.84) for tendon thickening to 0.82 (0.66, 0.90) for overall greyscale score and 0.86 (0.73, 0.93) for calcification. The MDC for the greyscale total score was 2.0/12 and for the hyperaemia score was 1.1/5. The sonographic scoring system used in this study may be used reliably to quantify tendon abnormalities and change over time. A relatively inexperienced imager can conduct the assessment and use the rating scales reliably.

  4. Hippocampal MRI volumetry at 3 Tesla: reliability and practical guidance.

    Science.gov (United States)

    Jeukens, Cécile R L P N; Vlooswijk, Mariëlle C G; Majoie, H J Marian; de Krom, Marc C T F M; Aldenkamp, Albert P; Hofman, Paul A M; Jansen, Jacobus F A; Backes, Walter H

    2009-09-01

    Although volumetry of the hippocampus is considered to be an established technique, protocols reported in literature are not described in great detail. This article provides a complete and detailed protocol for hippocampal volumetry applicable to T1-weighted magnetic resonance (MR) images acquired at 3 Tesla, which has become the standard for structural brain research. The protocol encompasses T1-weighted image acquisition at 3 Tesla, anatomic guidelines for manual hippocampus delineation, requirements of delineation software, reliability measures, and criteria to assess and ensure sufficient reliability. Moreover, the validity of the correction for total intracranial volume size was critically assessed. The protocol was applied by 2 readers to the MR images of 36 patients with cryptogenic localization-related epilepsy, 4 patients with unilateral hippocampal sclerosis, and 20 healthy control subjects. The uncorrected hippocampal volumes were 2923 +/- 500 mm3 (mean +/- SD) (left) and 3120 +/- 416 mm3 (right) for the patient group and 3185 +/- 411 mm3 (left) and 3302 +/- 411 mm3 (right) for the healthy control group. The volume of the 4 pathologic hippocampi of the patients with unilateral hippocampal sclerosis was 2980 +/- 422 mm3. The inter-reader reliability values were determined: intraclass-correlation-coefficient (ICC) = 0.87 (left) and 0.86 (right), percentage volume difference (VD) = 7.0 +/- 4.7% (left) and 6.0 +/- 3.8% (right), and overlap ratio (OR) = 0.82 +/- 0.04 (left) and 0.82 +/- 0.03 (right). The positive Pearson correlation between hippocampal volume and total intracranial volume was found to be low: r = 0.48 (P = 0.03, left) and r = 0.62 (P = 0.004, right) and did not significantly reduce the volumetric variances, showing the limited benefit of the brain size correction. A protocol was described to determine hippocampal volumes based on 3 Tesla MR images with high inter-reader reliability. Although the reliability of hippocampal volumetry at 3 Tesla

  5. Trial of prestressed concrete cable testing by sonic integrity tester

    International Nuclear Information System (INIS)

    Sugimoto, Masanobu

    1997-01-01

    Highway road network of Japan is in good condition. Those roads were constructed as social infrastructures. But some damages were occurred and propagated in concrete structure which passed more than 20 years after construction. As for the damages load caring capacity of bridge was decreased due to fatigue of increasing traffics and bridge vibration. Recently many troubles happened in PC structure as cut off of the main cables by corrosion and flying the non-grouting PC-bar to roadside. Some case can be checked by hammering testing method and X-ray photo cut or not and condition of cement grouting. But another case has not checking method. Now we are testing for the PC cables by sonic integrity tester which is modified from FPDS(Foundation Pile Diagnosis System). We report in this paper on this result and scope of the future of this method.

  6. Reliability analysis of component of affination centrifugal 1 machine by using reliability engineering

    Science.gov (United States)

    Sembiring, N.; Ginting, E.; Darnello, T.

    2017-12-01

    Problems that appear in a company that produces refined sugar, the production floor has not reached the level of critical machine availability because it often suffered damage (breakdown). This results in a sudden loss of production time and production opportunities. This problem can be solved by Reliability Engineering method where the statistical approach to historical damage data is performed to see the pattern of the distribution. The method can provide a value of reliability, rate of damage, and availability level, of an machine during the maintenance time interval schedule. The result of distribution test to time inter-damage data (MTTF) flexible hose component is lognormal distribution while component of teflon cone lifthing is weibull distribution. While from distribution test to mean time of improvement (MTTR) flexible hose component is exponential distribution while component of teflon cone lifthing is weibull distribution. The actual results of the flexible hose component on the replacement schedule per 720 hours obtained reliability of 0.2451 and availability 0.9960. While on the critical components of teflon cone lifthing actual on the replacement schedule per 1944 hours obtained reliability of 0.4083 and availability 0.9927.

  7. Reliability analysis for manual radiographic measures of rotatory subluxation or lateral listhesis in adult scoliosis.

    Science.gov (United States)

    Freedman, Brett A; Horton, William C; Rhee, John M; Edwards, Charles C; Kuklo, Timothy R

    2009-03-15

    Retrospective observational study. To define the inter- and intraobserver reliability of 3 measures of rotatory subluxation (RS) in adult scoliosis (AS). RS is a hallmark of AS. To accurately track this measure, one must know its reliability. Reliability testing has not been performed. PA 36" films of 29 AS patients were collected from one surgeon's practice. Three observers on 2 separate occasions measured all levels with >or=3-mm RS (60 levels, 360 measurements) on the convexity of the involved segment using 3 different techniques-midbody (MB), endplate (EP), and centroid (C). These data were then analyzed to determine the intraclass correlation coefficient (ICC) for inter- and intraobserver reliability. The thoracolumbar/lumbar curve (average 58 degrees ) was the major curve for the majority (62%) of patients. RS at L3/4 was most common (35%). The overall inter- and intraobserver reliability was good-excellent for all methods, but the centroid method consistently had the highest ICC. ICC correlated with observer experience. Moderate-severe arthritic change (present in 55%) and poor image quality (52%) decreased ICC, but it still remained good-excellent for each measure. The reproducibility coefficient for each measure was 4 mm for MB and 2.8 mm for C and EP. MB, EP, and C are reliable techniques to measure RS even in elderly arthritic spines, but the methods inherently produce different values for a given level. The centroid method is most reliable and least influenced by experience. The EP method is easy to perform and very reliable. Spine surgeons should pick their preferred method and apply it consistently. Changes >3 mm suggest RS progression. RS may be a useful measure in addition to Cobb angle in AS. Having defined measurement reliability, the role of RS progression in surgical indications and patient outcomes can be evaluated.

  8. Survey of industry methods for producing highly reliable software

    International Nuclear Information System (INIS)

    Lawrence, J.D.; Persons, W.L.

    1994-11-01

    The Nuclear Reactor Regulation Office of the US Nuclear Regulatory Commission is charged with assessing the safety of new instrument and control designs for nuclear power plants which may use computer-based reactor protection systems. Lawrence Livermore National Laboratory has evaluated the latest techniques in software reliability for measurement, estimation, error detection, and prediction that can be used during the software life cycle as a means of risk assessment for reactor protection systems. One aspect of this task has been a survey of the software industry to collect information to help identify the design factors used to improve the reliability and safety of software. The intent was to discover what practices really work in industry and what design factors are used by industry to achieve highly reliable software. The results of the survey are documented in this report. Three companies participated in the survey: Computer Sciences Corporation, International Business Machines (Federal Systems Company), and TRW. Discussions were also held with NASA Software Engineering Lab/University of Maryland/CSC, and the AIAA Software Reliability Project

  9. Intra- and interrater reliability of the Chicago Classification of achalasia subtypes in pediatric high-resolution esophageal manometry (HRM) recordings.

    Science.gov (United States)

    Singendonk, M M J; Rosen, R; Oors, J; Rommel, N; van Wijk, M P; Benninga, M A; Nurko, S; Omari, T I

    2017-11-01

    Subtyping achalasia by high-resolution manometry (HRM) is clinically relevant as response to therapy and prognosis have shown to vary accordingly. The aim of this study was to assess inter- and intrarater reliability of diagnosing achalasia and achalasia subtyping in children using the Chicago Classification (CC) V3.0. Six observers analyzed 40 pediatric HRM recordings (22 achalasia and 18 non-achalasia) twice by using dedicated analysis software (ManoView 3.0, Given Imaging, Los Angeles, CA, USA). Integrated relaxation pressure (IRP4s), distal contractile integral (DCI), intrabolus pressurization pattern (IBP), and distal latency (DL) were extracted and analyzed hierarchically. Cohen's κ (2 raters) and Fleiss' κ (>2 raters) and the intraclass correlation coefficient (ICC) were used for categorical and ordinal data, respectively. Based on the results of dedicated analysis software only, intra- and interrater reliability was excellent and moderate (κ=0.89 and κ=0.52, respectively) for differentiating achalasia from non-achalasia. For subtyping achalasia, reliability decreased to substantial and fair (κ=0.72 and κ=0.28, respectively). When observers were allowed to change the software-driven diagnosis according to their own interpretation of the manometric patterns, intra- and interrater reliability increased for diagnosing achalasia (κ=0.98 and κ=0.92, respectively) and for subtyping achalasia (κ=0.79 and κ=0.58, respectively). Intra- and interrater agreement for diagnosing achalasia when using HRM and the CC was very good to excellent when results of automated analysis software were interpreted by experienced observers. More variability was seen when relying solely on the software-driven diagnosis and for subtyping achalasia. Therefore, diagnosing and subtyping achalasia should be performed in pediatric motility centers with significant expertise. © 2017 John Wiley & Sons Ltd.

  10. Estudo da validade e confiabilidade intra e interobservador da versão modificada do teste de Schöber modificado em indivíduos com lombalgia Study of validity and intra and inter-observer reliability of modified-modified Schöber test in subjects with low-back pain

    Directory of Open Access Journals (Sweden)

    Christiane de Souza Guerino Macedo

    2009-09-01

    measures obtained via MMST and radiography was r=0.14, showing a poor correlation between the tests. The intra-observer intraclass correlation coefficient (ICC found was 0.96 (CI 95% 0.91;0.98, and the inter-observer ICC was 0.93 (IC 95% 0.84;0.97, showing high reliability; the Bland & Altman agreement test showed high agreement intra (-0.21 and inter-observer (-0.21. Although a high reliability both intra and inter-observer was found for the modified-modified Schöber test, the latter showed low validity in assessing lumbar spine range of motion, when compared to the gold standard.

  11. Reliability, validity and description of timed performance of the Jebsen-Taylor Test in patients with muscular dystrophies.

    Science.gov (United States)

    Artilheiro, Mariana Cunha; Fávero, Francis Meire; Caromano, Fátima Aparecida; Oliveira, Acary de Souza Bulle; Carvas, Nelson; Voos, Mariana Callil; Sá, Cristina Dos Santos Cardoso de

    2017-12-08

    The Jebsen-Taylor Test evaluates upper limb function by measuring timed performance on everyday activities. The test is used to assess and monitor the progression of patients with Parkinson disease, cerebral palsy, stroke and brain injury. To analyze the reliability, internal consistency and validity of the Jebsen-Taylor Test in people with Muscular Dystrophy and to describe and classify upper limb timed performance of people with Muscular Dystrophy. Fifty patients with Muscular Dystrophy were assessed. Non-dominant and dominant upper limb performances on the Jebsen-Taylor Test were filmed. Two raters evaluated timed performance for inter-rater reliability analysis. Test-retest reliability was investigated by using intraclass correlation coefficients. Internal consistency was assessed using the Cronbach alpha. Construct validity was conducted by comparing the Jebsen-Taylor Test with the Performance of Upper Limb. The internal consistency of Jebsen-Taylor Test was good (Cronbach's α=0.98). A very high inter-rater reliability (0.903-0.999), except for writing with an Intraclass correlation coefficient of 0.772-1.000. Strong correlations between the Jebsen-Taylor Test and the Performance of Upper Limb Module were found (rho=-0.712). The Jebsen-Taylor Test is a reliable and valid measure of timed performance for people with Muscular Dystrophy. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  12. Inter-rater agreement of the PEWS tools used in Central Denmark Region

    DEFF Research Database (Denmark)

    Jensen, Claus Sixtus; Aagaard, Hanne; Olesen, Hanne Vebert

    2017-01-01

    BACKGROUND: Paediatric early warning score (PEWS) assessment tools can assist healthcare providers in the timely detection and recognition of subtle patient condition changes signalling clinical deterioration. However, PEWS tools instrument data are only as reliable and accurate as the caregivers...... agreement. The nurses assigned the exact same aggregated score for both PEWS models in 76% of the cases. In 98% of the PEWS assessments, the aggregated PEWS scores assigned by the nurses were equal to or below 1 point in both models. CONCLUSION: The study showed good to very good inter-rater reliability...

  13. Engineering high reliability, low-jitter Marx generators

    International Nuclear Information System (INIS)

    Schneider, L.X.; Lockwood, G.J.

    1985-01-01

    Multimodule pulsed power accelerators typically require high module reliability and nanosecond regime simultaneity between modules. Energy storage using bipolar Marx generators can meet these requirements. Experience gained from computer simulations and the development of the DEMON II Marx generator has led to a fundamental understanding of the operation of these multistage devices. As a result of this research, significant improvements in erection time jitter and reliability have been realized in multistage, bipolar Marx generators. Erection time jitter has been measured as low as 2.5 nanoseconds for the 3.2MV, 16-stage PBFA I Marx and 3.5 nanoseconds for the 6.0MV, 30-stage PBFA II (DEMON II) Marx, while maintaining exceptionally low prefire rates. Performance data are presented from the DEMON II Marx research program, as well as discussions on the use of computer simulations in designing low-jitter Marx generators

  14. Radioprotective action of glycerol and cysteamine on inactivation and mutagenesis in Salmonella tester strains after gamma and heavy ion irradiation

    International Nuclear Information System (INIS)

    Basha, S.G.; Krasavin, E.A.; Kozubek, S.

    1991-01-01

    Inactivation and mutagenesis were studied in Salmonella tester strains after γ-irradiation and after heavy ion irradiation in the presence of glycerol and cysteamine. Bacterial cells were irradiated at Dubna, JINR. Ions from deuterons to carbon were used with residual energies 2-9 MeV/u. The protective effect of glycerol was found both for γ-radiation and for heavy ions up to 50 keV/μm for both cell inactivation and mutagenesis in Salmonella tester strains with different mutation events. Cell sensitivity slightly increased with LET before falling down. The maximum was shifted in the presence of glycerol to the left and was less pronounced. The radioprotective effect of glycerol diminished gradually with LET from 2.0 for γ-radiation to 1.1 for carbon ions. Mutagenesis increases with LET in TA100 strain; in TA98 strain no marked increase could be detected. 13 refs.; 4 figs.; 5 tabs

  15. LVDS tester: a systematic test of cable signal transmission at the ALICE experiment

    CERN Document Server

    Barnby, L; Bombara, M; Evans, D; Jones, G T; Jones, P G; Jovanović, P; Jusko, A; Kour, R; Králik, I; Krivda, M; Lazzeroni, C; Lietava, R; Matthews, Z L; Navin, S; Palaha, A; Petrov, P; Platt, R; Šándor, L; Scott, P; Urbán, J; Villalobos Baillie, O; Tapia Takaki, J D

    2010-01-01

    In the ALICE experiment, the Low-Voltage Differential Signalling (LVDS) format is used for the transmission of trigger inputs from the detectors to the Central Trigger Processor (CTP), the L0 trigger outputs from Local Trigger Units (LTU) boards back to the detectors and the BUSY inputs from the sub-detectors to the CTP. ALICE has designed a set-up, called the LVDS transmission tester, that aims to measure various transmission quality parameters and the bit-error rate (BER) for long period runs in an automatic way. In this paper, this method is described and the conclusions from these tests for the ALICE LVDS cables are discussed

  16. LVDS tester: a systematic test of cable signal transmission at the ALICE experiment

    International Nuclear Information System (INIS)

    Barnby, L; Bhasin, A; Evans, D; Jones, G T; Jones, P G; Jovanovic, P; Jusko, A; Kour, R; Krivda, M; Lazzeroni, C; Lietava, R; Matthews, Z L; Navin, S; Palaha, A; Petrov, P; Platt, R; Scott, P; Bombara, M; Kralik, I; Sandor, L

    2010-01-01

    In the ALICE experiment, the Low-Voltage Differential Signalling (LVDS) format is used for the transmission of trigger inputs from the detectors to the Central Trigger Processor (CTP), the L0 trigger outputs from Local Trigger Units (LTU) boards back to the detectors and the BUSY inputs from the sub-detectors to the CTP. ALICE has designed a set-up, called the LVDS transmission tester, that aims to measure various transmission quality parameters and the bit-error rate (BER) for long period runs in an automatic way. In this paper, this method is described and the conclusions from these tests for the ALICE LVDS cables are discussed.

  17. The reliability of the Brazilian version of the Composite International Diagnostic Interview (CIDI 2.1

    Directory of Open Access Journals (Sweden)

    Quintana M.I.

    2004-01-01

    Full Text Available The objective of the present study was to determine the reliability of the Brazilian version of the Composite International Diagnostic Interview 2.1 (CIDI 2.1 in clinical psychiatry. The CIDI 2.1 was translated into Portuguese using WHO guidelines and reliability was studied using the inter-rater reliability method. The study sample consisted of 186 subjects from psychiatric hospitals and clinics, primary care centers and community services. The interviewers consisted of a group of 13 lay and three non-lay interviewers submitted to the CIDI training. The average interview time was 2 h and 30 min. General reliability ranged from kappa 0.50 to 1. For lifetime diagnoses the reliability ranged from kappa 0.77 (Bipolar Affective Disorder to 1 (Substance-Related Disorder, Alcohol-Related Disorder, Eating Disorders. Previous year reliability ranged from kappa 0.66 (Obsessive-Compulsive Disorder to 1 (Dissociative Disorders, Maniac Disorders, Eating Disorders. The poorest reliability rate was found for Mild Depressive Episode (kappa = 0.50 during the previous year. Training proved to be a fundamental factor for maintaining good reliability. Technical knowledge of the questionnaire compensated for the lack of psychiatric knowledge of the lay personnel. Inter-rater reliability was good to excellent for persons in psychiatric practice.

  18. Inter-comparison of High Energy Files (neutron-induced, from 20 to 150 MeV)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young-Ouk; Fukahori, Tokio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-11-01

    Recent new applications using accelerator-driven system require well-tested nuclear data when modeling the interaction of neutrons above 20 MeV. This work is aimed to review evaluation methods applied in currently available neutron high energy files above 20 to 150 MeV, to inter-compare their evaluated cross sections on some important isotopes, and to analyze resulting discrepancies. Through out these, integrities and consistencies of the high energy files are checked, applicability of physics models and evaluation methodologies are assessed, and some directions are derived to improve and expand current JENDL High Energy File. (author)

  19. Reliability of Autism-Tics, AD/HD, and other Comorbidities (A-TAC) inventory in a test-retest design.

    Science.gov (United States)

    Larson, Tomas; Kerekes, Nóra; Selinus, Eva Norén; Lichtenstein, Paul; Gumpert, Clara Hellner; Anckarsäter, Henrik; Nilsson, Thomas; Lundström, Sebastian

    2014-02-01

    The Autism-Tics, AD/HD, and other Comorbidities (A-TAC) inventory is used in epidemiological research to assess neurodevelopmental problems and coexisting conditions. Although the A-TAC has been applied in various populations, data on retest reliability are limited. The objective of the present study was to present additional reliability data. The A-TAC was administered by lay assessors and was completed on two occasions by parents of 400 individual twins, with an average interval of 70 days between test sessions. Intra- and inter-rater reliability were analysed with intraclass correlations and Cohen's kappa. A-TAC showed excellent test-retest intraclass correlations for both autism spectrum disorder and attention deficit hyperactivity disorder (each at .84). Most modules in the A-TAC had intra- and inter-rater reliability intraclass correlation coefficients of > or = .60. Cohen's kappa indi- cated acceptable reliability. The current study provides statistical evidence that the A-TAC yields good test-retest reliability in a population-based cohort of children.

  20. Instrument reliability for high-level nuclear-waste-repository applications

    International Nuclear Information System (INIS)

    Rogue, F.; Binnall, E.P.; Armantrout, G.A.

    1983-01-01

    Reliable instrumentation will be needed to evaluate the characteristics of proposed high-level nuclear-wasted-repository sites and to monitor the performance of selected sites during the operational period and into repository closure. A study has been done to assess the reliability of instruments used in Department of Energy (DOE) waste repository related experiments and in other similar geological applications. The study included experiences with geotechnical, hydrological, geochemical, environmental, and radiological instrumentation and associated data acquisition equipment. Though this paper includes some findings on the reliability of instruments in each of these categories, the emphasis is on experiences with geotechnical instrumentation in hostile repository-type environments. We review the failure modes, rates, and mechanisms, along with manufacturers modifications and design changes to enhance and improve instrument performance; and include recommendations on areas where further improvements are needed