WorldWideScience

Sample records for high intensity performance

  1. Ultra High Performance, Highly Reliable, Numeric Intensive Processors and Systems

    Science.gov (United States)

    1989-10-01

    to design high-performance DSP/IP systems using either off-the-shelf components or application specific integrated circuitry [ ASIC ]. -9 - HSDAL . ARO...are the chirp-z transform ( CZT ) [13] and (Rader’s) Prime Factor Transform (PFT) [11]. The RNS/ CZT is being studied by a group a MITRE [14] and is given...PFT RNS/CRNS/QRNS implementation has dynamic range requirements on the order of NQ2 (vs NQ4 for the CZT and much higher for the FFT). Therefore, the

  2. The development of a high intensity dance performance fitness test.

    Science.gov (United States)

    Redding, Emma; Weller, Peter; Ehrenberg, Shantel; Irvine, Sarah; Quin, Edel; Rafferty, Sonia; Wyon, Matthew; Cox, Carol

    2009-01-01

    While there is currently a validated dance-specific exercise method of measuring aerobic fitness, no such test has been developed to measure high intensity capabilities in dance. The purpose of this study was to initiate an intermittent high intensity dance-specific fitness test. The test was designed to be able to observe changes in heart rate (HR), thereby allowing for a measurement of physical fitness at high intensities. Sixteen professional dancers (4 males and 12 females) volunteered to take part in this study. The fitness test protocol consists of movements that are representative of contemporary dance, and contains exercise and rest periods that mimic the intermittent nature of dance. The participants performed four trials. The physiological variables measured were HR (b.min(-1)) for each one minute bout of the four minute test for all trials, oxygen uptake (VO(2)) throughout the test, and end blood lactate (BLa mmol.L) for each trial. In addition, five of the participants undertook a maximal oxygen uptake treadmill test, and the scores obtained were compared with those from the dance test. Results show HR consistency across each one minute bout of the test and across each of the four trials of testing for all participants, indicating that the test is reliable. There was good reliability between bouts of each trial (typical error as % of CV = 1.5), intraclass "r" = 0.8, and good reliability between the four trials (typical error as % of CV = 2.1), intraclass "r" = 0.82. There were no significant differences between the maximal VO(2) and BLa scores established in the treadmill and dance tests, demonstrating validity. Thus, the results of this study indicate that the high intensity dance-specific test is a reliable and valid means of assessing and monitoring the cardiovascular fitness of dancers. The test allows dancers to be assessed within an environment that they are accustomed to (the studio), using a mode of exercise that is relevant (dance), and it is

  3. Pedalling rate affects endurance performance during high-intensity cycling

    DEFF Research Database (Denmark)

    Nielsen, Jens Steen; Hansen, Ernst Albin; Sjøgaard, Gisela

    2004-01-01

    , such as muscle fibre type composition and power reserve, relate to endurance time. Twenty males underwent testing to determine their maximal oxygen uptake (VO(2max)), power output corresponding to 90% of VO(2max) at 80 rpm (W90), FCPR at W90, percentage of slow twitch muscle fibres (% MHC I), maximal leg power...... time was negatively related to VO(2max), W90 and % MHC I, while positively related to power reserve. In conclusion, at group level, endurance time was longer at FCPR and at a pedalling rate 25% lower compared to a pedalling rate 25% higher than FCPR. Further, inter-individual physiological variables......The purpose of this study into high-intensity cycling was to: (1) test the hypothesis that endurance time is longest at a freely chosen pedalling rate (FCPR), compared to pedalling rates 25% lower (FCPR-25) and higher (FCPR+25) than FCPR, and (2) investigate how physiological variables...

  4. High Performance Data Transfer for Distributed Data Intensive Sciences

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Chin [Zettar Inc., Mountain View, CA (United States); Cottrell, R ' Les' A. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Hanushevsky, Andrew B. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Kroeger, Wilko [SLAC National Accelerator Lab., Menlo Park, CA (United States); Yang, Wei [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2017-03-06

    We report on the development of ZX software providing high performance data transfer and encryption. The design scales in: computation power, network interfaces, and IOPS while carefully balancing the available resources. Two U.S. patent-pending algorithms help tackle data sets containing lots of small files and very large files, and provide insensitivity to network latency. It has a cluster-oriented architecture, using peer-to-peer technologies to ease deployment, operation, usage, and resource discovery. Its unique optimizations enable effective use of flash memory. Using a pair of existing data transfer nodes at SLAC and NERSC, we compared its performance to that of bbcp and GridFTP and determined that they were comparable. With a proof of concept created using two four-node clusters with multiple distributed multi-core CPUs, network interfaces and flash memory, we achieved 155Gbps memory-to-memory over a 2x100Gbps link aggregated channel and 70Gbps file-to-file with encryption over a 5000 mile 100Gbps link.

  5. Glucocorticoids improve high-intensity exercise performance in humans

    DEFF Research Database (Denmark)

    Casuso, Rafael A; Melskens, Lars; Bruhn, Thomas

    2014-01-01

    It was investigated whether oral dexamethasone (DEX) administration improves exercise performance by reducing the initial rate of muscle fatigue development during dynamic exercise.......It was investigated whether oral dexamethasone (DEX) administration improves exercise performance by reducing the initial rate of muscle fatigue development during dynamic exercise....

  6. High performance computation on beam dynamics problems in high intensity compact cyclotrons

    Institute of Scientific and Technical Information of China (English)

    ADELMANN; Andreas

    2011-01-01

    This paper presents the research progress in the beam dynamics problems for future high intensity compact cyclotrons by utilizing the state-of-the-art high performance computation technology. A "Start-to-Stop" model, which includes both the interaction of the internal particles of a single bunch and the mutual interaction of neighboring multiple bunches in the radial direction, is established for compact cyclotrons with multi-turn extraction. This model is then implemented in OPAL-CYCL, which is a 3D object-oriented parallel code for large scale particle simulations in cyclotrons. In addition, to meet the running requirement of parallel computation, we have constructed a small scale HPC cluster system and tested its performance. Finally, the high intensity beam dynamics problems in the 100 MeV compact cyclotron, which is being constructed at CIAE, are studied using this code and some conclusions are drawn.

  7. Meeting standards of high-quality intensive care unit palliative care: clinical performance and predictors.

    Science.gov (United States)

    Penrod, Joan D; Pronovost, Peter J; Livote, Elayne E; Puntillo, Kathleen A; Walker, Amy S; Wallenstein, Sylvan; Mercado, Alice F; Swoboda, Sandra M; Ilaoa, Debra; Thompson, David A; Nelson, Judith E

    2012-04-01

    High-quality care for intensive care unit patients and families includes palliative care. To promote performance improvement, the Agency for Healthcare Research and Quality's National Quality Measures Clearinghouse identified nine evidence-based processes of intensive care unit palliative care (Care and Communication Bundle) that are measured through review of medical record documentation. We conducted this study to examine how frequently the Care and Communication Bundle processes were performed in diverse intensive care units and to understand patient factors that are associated with such performance. Prospective, multisite, observational study of performance of key intensive care unit palliative care processes. A surgical intensive care unit and a medical intensive care unit in two different large academic health centers and a medical-surgical intensive care unit in a medium-sized community hospital. Consecutive adult patients with length of intensive care unit stay ≥5 days. None. Between November 2007 and December 2009, we measured performance by specified day after intensive care unit admission on nine care process measures: Identify medical decision-maker, advance directive and resuscitation preference, distribute family information leaflet, assess and manage pain, offer social work and spiritual support, and conduct interdisciplinary family meeting. Multivariable regression analysis was used to determine predictors of performance of five care processes. We enrolled 518 (94.9%) patients and 336 (83.6%) family members. Performances on pain assessment and management measures were high. In contrast, interdisciplinary family meetings were documented for <20% of patients by intensive care unit day 5. Performance on other measures ranged from 8% to 43%, with substantial variation across and within sites. Chronic comorbidity burden and site were the most consistent predictors of care process performance. Across three intensive care units in this study, performance

  8. High Performance Human Face Recognition using Independent High Intensity Gabor Wavelet Responses: A Statistical Approach

    CERN Document Server

    Kar, Arindam; Basu, Dipak Kumar; Nasipuri, Mita; Kundu, Mahantapas

    2011-01-01

    In this paper, we present a technique by which high-intensity feature vectors extracted from the Gabor wavelet transformation of frontal face images, is combined together with Independent Component Analysis (ICA) for enhanced face recognition. Firstly, the high-intensity feature vectors are automatically extracted using the local characteristics of each individual face from the Gabor transformed images. Then ICA is applied on these locally extracted high-intensity feature vectors of the facial images to obtain the independent high intensity feature (IHIF) vectors. These IHIF forms the basis of the work. Finally, the image classification is done using these IHIF vectors, which are considered as representatives of the images. The importance behind implementing ICA along with the high-intensity features of Gabor wavelet transformation is twofold. On the one hand, selecting peaks of the Gabor transformed face images exhibit strong characteristics of spatial locality, scale, and orientation selectivity. Thus these...

  9. Meeting standards of high-quality intensive care unit palliative care: Clinical performance and predictors

    Science.gov (United States)

    Penrod, Joan D.; Pronovost, Peter J.; Livote, Elayne E.; Puntillo, Kathleen A.; Walker, Amy S.; Wallenstein, Sylvan; Mercado, Alice F.; Swoboda, Sandra M.; Ilaoa, Debra; Thompson, David A.; Nelson, Judith E.

    2012-01-01

    Objectives High-quality care for intensive care unit patients and families includes palliative care. To promote performance improvement, the Agency for Healthcare Research and Quality’s National Quality Measures Clearinghouse identified nine evidence-based processes of intensive care unit palliative care (Care and Communication Bundle) that are measured through review of medical record documentation. We conducted this study to examine how frequently the Care and Communication Bundle processes were performed in diverse intensive care units and to understand patient factors that are associated with such performance. Design Prospective, multisite, observational study of performance of key intensive care unit palliative care processes. Settings A surgical intensive care unit and a medical intensive care unit in two different large academic health centers and a medical-surgical intensive care unit in a medium-sized community hospital. Patients Consecutive adult patients with length of intensive care unit stay ≥5 days. Interventions None. Measurements and Main Results Between November 2007 and December 2009, we measured performance by specified day after intensive care unit admission on nine care process measures: identify medical decision-maker, advance directive and resuscitation preference, distribute family information leaflet, assess and manage pain, offer social work and spiritual support, and conduct interdisciplinary family meeting. Multivariable regression analysis was used to determine predictors of performance of five care processes. We enrolled 518 (94.9%) patients and 336 (83.6%) family members. Performances on pain assessment and management measures were high. In contrast, interdisciplinary family meetings were documented for <20% of patients by intensive care unit day 5. Performance on other measures ranged from 8% to 43%, with substantial variation across and within sites. Chronic comorbidity burden and site were the most consistent predictors of care

  10. Warm-up strategy and high-intensity endurance performance in trained cyclists

    DEFF Research Database (Denmark)

    Christensen, Peter Møller; Bangsbo, Jens

    2015-01-01

    PURPOSE: To evaluate the influence of warm-up exercise intensity and subsequent recovery on intense endurance performance, selected blood variables and the VO2 response. METHODS: Twelve highly trained male cyclists (VO2-max: 72.4±8.0·mL/min/kg, incremental-test peak power output (iPPO): 432±31 W......; means±SD) performed three warm-up strategies lasting 20 min before a 4-min maximal performance test (PT). Strategies consisted of moderate intensity exercise (50%iPPO) followed by 6 min of recovery (MOD6) or progressive-high intensity exercise (10-100%iPPO and 2x20-s sprints) followed by recovery for 6...... to HI20 (7.85±0.82 L; P=0.008) and MOD6 (7.90±0.74 L; P=0.012). CONCLUSIONS: Warm-up exercise including race-pace and sprint intervals combined with short recovery can reduce subsequent performance in a 4-min maximal test in highly trained cyclists. Thus, a reduced time at high exercise intensity...

  11. A numerical and experimental investigation of the performance of sound intensity probes at high frequencies

    DEFF Research Database (Denmark)

    Jacobsen, Finn; Cutanda, Vicente; Juhl, Peter Møller

    1998-01-01

    The high-frequency performance of a p-p intensity probe with a solid spacer between the two microphones is examined. It is shown theoretically and verified experimentally that with a spacer length that equals the diameter of the microphones, the finite difference error is almost perfectly cancelled...

  12. High-intensity interval training and athletic performance in Taekwondo athletes.

    Science.gov (United States)

    Monks, Lynne; Seo, Myong-Won; Kim, Hyun-Bae; Jung, Hyun C; Song, Jong K

    2017-10-01

    The purpose of this study was to determine the effects of high-intensity interval training (HIIT) on athletic performance in Taekwondo athletes. Thirty-three male and female collegiate Taekwondo athletes were randomly divided into a HIIT group (N.=16) or a high-intensity continuous running (HICR) group (N.=17). The HIIT group undertook training of high-intensity sprints interspersed with active rest periods whilst the HICR group participated in high-intensity running for a continuous period. Both groups completed 11 sessions over 4 weeks. Physique, body composition, Wingate anaerobic test and VO2max test were measured. The vertical jump test, agility T-test and sit-ups were used to assess physical fitness. Repeated measures ANCOVAs with sex as a covariate were applied and significant level was set at 0.05. Following 11 sessions of training, significant improvements in anaerobic peak power (PTaekwondo competition performance in collegiate Taekwondo athletes. This could inform the future planning of Taekwondo athletes' pre-competition training, specifically the influence of training intensity on anaerobic capacity.

  13. Perceptual feeling and time-of-day effects on high intensity exercise performance

    Directory of Open Access Journals (Sweden)

    MARIE CLARE MCCORMICK

    2012-01-01

    Full Text Available The present study was designed to investigate the effect of time of day and perceptual feeling on high intensity cycle ergometry and related performance during ‘normal working hours’. Eleven male participants (22.9 ± 2.6yrs; 182 ± 0.06cm; 80.43 ± 14.39kg were tested over a 12 h period (08:00-20:00 h. Every hour, on the hour, participants performed a 10s maximal leg cycle ergometry test and completed an Exercise-Induced Feeling Inventory (EFI; every hour, on the half hour, they performed a standing broad jump (SBJ, hand grip test (HG and vertical jump (VJ. Participants were instructed that each test required maximum effort. The main results show that there were no significant differences during the 12h experimental period in any of the performance variables (P > 0.05. However, peak power output during the high intensity cycle ergometry and distance and height achieved during the SBJ and VJ test along with positive engagement all peaked at 19:00h. The results show that high intensity cycle ergometry and related physiological measures are not affected by the time of day during ‘normal working hours’. However, the data suggests that maximal performance is moderately affected by motivational levels of participants and therefore when using maximal exercise tests investigators should ensure that participants are highly motivated.

  14. The effect of an intermittent, high-intensity warm-up on supramaximal kayak ergometer performance.

    Science.gov (United States)

    Bishop, David; Bonetti, Darrel; Spencer, Matthew

    2003-01-01

    It has previously been shown that the metabolic acidaemia induced by a continuous warm-up at the 'lactate threshold' is associated with a reduced accumulated oxygen deficit and decreased supramaximal performance. The aim of this study was to determine if an intermittent, high-intensity warm-up could increase oxygen uptake (VO2) without reducing the accumulated oxygen deficit, and thus improve supramaximal performance. Seven male 500 m kayak paddlers, who had represented their state, volunteered for this study. Each performed a graded exercise test to determine VO2max and threshold parameters. On subsequent days and in a random, counterbalanced order, the participants then performed a continuous or intermittent, high-intensity warm-up followed by a 2 min, all-out kayak ergometer test. The continuous warm-up consisted of 15 min of exercise at approximately 65% VO2max. The intermittent, high-intensity warm-up was similar, except that the last 5 min was replaced with five 10 s sprints at 200% VO2max, separated by 50 s of recovery at approximately 55% VO2max. Significantly greater (P kayak ergometer performance is significantly better after an intermittent rather than a continuous warm-up.

  15. Postexercise cold-water immersion improves intermittent high-intensity exercise performance in normothermia.

    Science.gov (United States)

    McCarthy, Avina; Mulligan, James; Egaña, Mikel

    2016-11-01

    A brief cold water immersion between 2 continuous high-intensity exercise bouts improves the performance of the latter compared with passive recovery in the heat. We investigated if this effect is apparent in normothermic conditions (∼19 °C), employing an intermittent high-intensity exercise designed to reflect the work performed at the high-intensity domain in team sports. Fifteen young active men completed 2 exhaustive cycling protocols (Ex1 and Ex2: 12 min at 85% ventilatory threshold (VT) and then an intermittent exercise alternating 30-s at 40% peak power (Ppeak) and 30 s at 90% Ppeak to exhaustion) separated by 15 min of (i) passive rest, (ii) 5-min cold-water immersion at 8 °C, and (iii) 10-min cold-water immersion at 8 °C. Core temperature, heart rate, rates of perceived exertion, and oxygen uptake kinetics were not different during Ex1 among conditions. Time to failure during the intermittent exercise was significantly (P intermittent high-intensity exercise compared with passive rest in normothermia due, at least in part, to reductions in core temperature, circulatory strain, and effort perception.

  16. High-intensity interval training has positive effects on performance in ice hockey players.

    Science.gov (United States)

    Naimo, M A; de Souza, E O; Wilson, J M; Carpenter, A L; Gilchrist, P; Lowery, R P; Averbuch, B; White, T M; Joy, J

    2015-01-01

    In spite of the well-known benefits that have been shown, few studies have looked at the practical applications of high-intensity interval training (HIIT) on athletic performance. This study investigated the effects of a HIIT program compared to traditional continuous endurance exercise training. 24 hockey players were randomly assigned to either a continuous or high-intensity interval group during a 4-week training program. The interval group (IG) was involved in a periodized HIIT program. The continuous group (CG) performed moderate intensity cycling for 45-60 min at an intensity that was 65% of their calculated heart rate reserve. Body composition, muscle thickness, anaerobic power, and on-ice measures were assessed pre- and post-training. Muscle thickness was significantly greater in IG (p=0.01) when compared to CG. The IG had greater values for both ∆ peak power (p<0.003) and ∆ mean power (p<0.02). Additionally, IG demonstrated a faster ∆ sprint (p<0.02) and a trend (p=0.08) for faster ∆ endurance test time to completion for IG. These results indicate that hockey players may utilize short-term HIIT to elicit positive effects in muscle thickness, power and on-ice performance.

  17. Joint Cooling does not Hinder Athletic Performance during High-intensity Intermittent Exercise.

    Science.gov (United States)

    Kim, H; Lee, D; Choi, H-M; Park, J

    2016-07-01

    We examined the effects of ankle and knee joint cooling on 20-m sprint times and maximal vertical jump heights during high-intensity intermittent exercise. 21 healthy collegiate male basketball (n=14) and handball players (n=7) underwent 3 experimental sessions. Each session consisted of four 15-min quarters of high-intensity intermittent exercises including various intensities of 20-m shuttle running and jumping. A 20-min bilateral joint cooling (ankle, knee, or control-no cooling: in a counterbalanced order) was applied before quarters 1 and 3. After joint cooling, no warm-up activity other than the exercise protocol was given. The 20-m sprint times and maximal vertical jump heights in each experimental session were recorded at baseline (prior to quarter-1) and during each quarter. To test joint cooling effects over time, we performed 3×5 mixed model ANOVAs. Neither ankle nor knee joint cooling changed 20-m sprint times (F8,280=1.45; p=0.18) or maximal vertical jump heights (F8,280=0.76; p=0.64). However, a trend was observed in which joint cooling immediately decreased (quarters 1 and 3) but active warm-up for approximately 20 min improved 20-min sprint times (quarters 2 and 4). Our study suggests that athletic performance such as sprinting and jumping are not altered by joint cooling applied prior to or during high-intensity intermittent exercise.

  18. Effect of high-intensity hypoxic training on sea-level swimming performances.

    Science.gov (United States)

    Truijens, M J; Toussaint, H M; Dow, J; Levine, B D

    2003-02-01

    The objective of this study was to test the hypothesis that high-intensity hypoxic training improves sea-level performances more than equivalent training in normoxia. Sixteen well-trained collegiate and Masters swimmers (10 women, 6 men) completed a 5-wk training program, consisting of three high-intensity training sessions in a flume and supplemental low- or moderate-intensity sessions in a pool each week. Subjects were matched for gender, performance level, and training history, and they were assigned to either hypoxic [Hypo; inspired O2 fraction (Fi(O(2))) = 15.3%, equivalent to a simulated altitude of 2,500 m] or normoxic (Norm; Fi(O(2)) = 20.9%) interval training in a randomized, double-blind, placebo-controlled design. All pool training occurred under Norm conditions. The primary performance measures were 100- and 400-m freestyle time trials. Laboratory outcomes included maximal O(2) uptake (Vo(2 max)), anaerobic capacity (accumulated O(2) deficit), and swimming economy. Significant (P = 0.02 and swimming performances and Vo(2 max) in well-trained swimmers, with no additive effect of hypoxic training.

  19. Influence of repeated bouts of eccentric exercise on high-intensity aerobic performance.

    Science.gov (United States)

    Higino, Wonder Passoni; Aparecido de Souza, Renato; Cavalcanti, Fabio de Sousa; Cardoso, Anderlei Dos Santos; Vasconcelos, Murilo Victor; Fernandes da Silva, Fabiano; Leme, José Alexandre C A

    2016-08-01

    [Purpose] It is believed that eccentric high-intensity exercise can decrease performance in subsequent exercise. However, with repetition, the deleterious effects can be minimized. Thus, this study evaluated the influence of repeated bouts of eccentric exercise on subsequent high-intensity aerobic performance. [Subjects and Methods] Seven healthy and sedentary male volunteers were recruited. a) Visit 1: determination of maximum oxygen uptake (VO2max) and speed associated with maximum oxygen uptake (vVO2max) in incremental treadmill testing; b) Visit 2: run to exhaustion at vVO2max (Tlim control); c) Visit 3: 10 sets of 10 depth jumps, followed by a run to exhaustion at vVO2max (Tlim 1); d) Visit 4: after 6 weeks without any physical training, the volunteers carried out the same procedures as on the third visit (Tlim 2). Data were analyzed using one-way analysis of variance (ANOVA) with the post-hoc Tukey test. [Results] Significant differences were found between Tlim control and Tlim 1 (283.4 ± 47.7 s vs. 125.2 ± 64.1 s, respectively), these were not different from Tlim 2. [Conclusion] Eccentric exercise showed deleterious effects on subsequent high-intensity aerobic performance. These effects were minimized after the exercise protocol was repeated 6 weeks after the first event.

  20. Beetroot Juice Supplementation Improves High-Intensity Intermittent Type Exercise Performance in Trained Soccer Players

    Science.gov (United States)

    Nyakayiru, Jean; Jonvik, Kristin L.; Trommelen, Jorn; Pinckaers, Philippe J. M.; Senden, Joan M.; van Loon, Luc J. C.; Verdijk, Lex B.

    2017-01-01

    It has been shown that nitrate supplementation can enhance endurance exercise performance. Recent work suggests that nitrate ingestion can also increase intermittent type exercise performance in recreational athletes. We hypothesized that six days of nitrate supplementation can improve high-intensity intermittent type exercise performance in trained soccer players. Thirty-two male soccer players (age: 23 ± 1 years, height: 181 ± 1 m, weight: 77 ± 1 kg, playing experience: 15.2 ± 0.5 years, playing in the first team of a 2nd or 3rd Dutch amateur league club) participated in this randomized, double-blind cross-over study. All subjects participated in two test days in which high-intensity intermittent running performance was assessed using the Yo-Yo IR1 test. Subjects ingested nitrate-rich (140 mL; ~800 mg nitrate/day; BR) or a nitrate-depleted beetroot juice (PLA) for six subsequent days, with at least eight days of wash-out between trials. The distance covered during the Yo-Yo IR1 was the primary outcome measure, while heart rate (HR) was measured continuously throughout the test, and a single blood and saliva sample were collected just prior to the test. Six days of BR ingestion increased plasma and salivary nitrate and nitrite concentrations in comparison to PLA (p < 0.001), and enhanced Yo-Yo IR1 test performance by 3.4 ± 1.3% (from 1574 ± 47 to 1623 ± 48 m; p = 0.027). Mean HR was lower in the BR (172 ± 2) vs. PLA trial (175 ± 2; p = 0.014). Six days of BR ingestion effectively improves high-intensity intermittent type exercise performance in trained soccer players. PMID:28327503

  1. Beetroot Juice Supplementation Improves High-Intensity Intermittent Type Exercise Performance in Trained Soccer Players

    Directory of Open Access Journals (Sweden)

    Jean Nyakayiru

    2017-03-01

    Full Text Available It has been shown that nitrate supplementation can enhance endurance exercise performance. Recent work suggests that nitrate ingestion can also increase intermittent type exercise performance in recreational athletes. We hypothesized that six days of nitrate supplementation can improve high-intensity intermittent type exercise performance in trained soccer players. Thirty-two male soccer players (age: 23 ± 1 years, height: 181 ± 1 m, weight: 77 ± 1 kg, playing experience: 15.2 ± 0.5 years, playing in the first team of a 2nd or 3rd Dutch amateur league club participated in this randomized, double-blind cross-over study. All subjects participated in two test days in which high-intensity intermittent running performance was assessed using the Yo-Yo IR1 test. Subjects ingested nitrate-rich (140 mL; ~800 mg nitrate/day; BR or a nitrate-depleted beetroot juice (PLA for six subsequent days, with at least eight days of wash-out between trials. The distance covered during the Yo-Yo IR1 was the primary outcome measure, while heart rate (HR was measured continuously throughout the test, and a single blood and saliva sample were collected just prior to the test. Six days of BR ingestion increased plasma and salivary nitrate and nitrite concentrations in comparison to PLA (p < 0.001, and enhanced Yo-Yo IR1 test performance by 3.4 ± 1.3% (from 1574 ± 47 to 1623 ± 48 m; p = 0.027. Mean HR was lower in the BR (172 ± 2 vs. PLA trial (175 ± 2; p = 0.014. Six days of BR ingestion effectively improves high-intensity intermittent type exercise performance in trained soccer players.

  2. High-intensity cycle interval training improves cycling and running performance in triathletes.

    Science.gov (United States)

    Etxebarria, Naroa; Anson, Judith M; Pyne, David B; Ferguson, Richard A

    2014-01-01

    Effective cycle training for triathlon is a challenge for coaches. We compared the effects of two variants of cycle high-intensity interval training (HIT) on triathlon-specific cycling and running. Fourteen moderately-trained male triathletes ([Formula: see text]O2peak 58.7 ± 8.1 mL kg(-1) min(-1); mean ± SD) completed on separate occasions a maximal incremental test ([Formula: see text]O2peak and maximal aerobic power), 16 × 20 s cycle sprints and a 1-h triathlon-specific cycle followed immediately by a 5 km run time trial. Participants were then pair-matched and assigned randomly to either a long high-intensity interval training (LONG) (6-8 × 5 min efforts) or short high-intensity interval training (SHORT) (9-11 × 10, 20 and 40 s efforts) HIT cycle training intervention. Six training sessions were completed over 3 weeks before participants repeated the baseline testing. Both groups had an ∼7% increase in [Formula: see text]O2peak (SHORT 7.3%, ±4.6%; mean, ±90% confidence limits; LONG 7.5%, ±1.7%). There was a moderate improvement in mean power for both the SHORT (10.3%, ±4.4%) and LONG (10.7%, ±6.8%) groups during the last eight 20-s sprints. There was a small to moderate decrease in heart rate, blood lactate and perceived exertion in both groups during the 1-h triathlon-specific cycling but only the LONG group had a substantial decrease in the subsequent 5-km run time (64, ±59 s). Moderately-trained triathletes should use both short and long high-intensity intervals to improve cycling physiology and performance. Longer 5-min intervals on the bike are more likely to benefit 5 km running performance.

  3. The Environmental Performance at Low Intensity, Low Temperature (LILT) of High Efficiency Triple Junction Solar Cells

    Science.gov (United States)

    Stella, Paul M.; Mueller, Robert; Davis, Gregory; Distefano, Salvador

    2004-01-01

    A number of JPL missions, either active or in the p l d g stages, require the accurate LILT flew intensity - low temperate) climate of triple-junction solar. Although triple ignition LILT performance was reported as recently as 2002, there has been an evolutionary advance in cell technology by both U.S. space cell manufacturers that, for mission design purposes, effectively obsoletes the earlier data. As a result, JPL initiated a program to develop a database for the LILT performance of the new high performance triple junction solar cells. JPL obtained Emcore Advanced triple Juntion CIC assemblies and Spectrolab Ultra Triple Junction CIC assemblies. These cells were tested at temperature-intensity ranges designed to cover applications between 1 and 5.18 AU solar distances. 1 MeV electron irradiation from 25 E14 to 1 El5 w were performed on the cells to evaluate the combined effect of particulate radiation and LILT conditions. The effect of LILT conditions was observed to incur an increase in the variation of cell performances such that at simulted 5.18 AU conditions the average performance was approximately 30% with the best cells measuring between 32 and 34% efficiency. The 30% average efficiency compares with approximately 25% average efficiency measured on earlier technology triple junction solar cells.

  4. High-Intensity Training Improves Exercise Performance in Elite Women Volleyball Players During a Competitive Season.

    Science.gov (United States)

    Purkhús, Elisabeth; Krustrup, Peter; Mohr, Magni

    2016-11-01

    Purkhús, E, Krustrup, P, and Mohr, M. High-intensity training improves exercise performance in elite women volleyball players during a competitive season. J Strength Cond Res 30(11): 3066-3072, 2016-Elite women volleyball players (n = 25; mean ± SD: age, 19 ± 5 years; height, 171 ± 7 cm; weight, 63 ± 10 kg) volunteered to participate in the study. They were randomized into a high-intensity training (HIT; n = 13) group and a control (CON; n = 12) group. In addition to the normal team training and games, HIT performed 6-10 × 30-seconds all-out running intervals separated by 3-minute recovery periods 3 times per week during a 4-week in-season period whereas CON only completed the team training sessions and games. Preintervention and postintervention, all players completed the arrowhead agility test (AAT), a repeated sprint test (RST; 5 × 30 meters separated by 25 seconds of recovery), and the Yo-Yo Intermittent Recovery level 2 test (Yo-Yo IR2) followed by a-10 minute rest period and the Yo-Yo IR1 test. Mean running distance during HIT in week 1 was 152 ± 4 m and increased (p ≤ 0.05) by 4.6% (159 ± 3 m) in week 4. The AAT performance improved (p ≤ 0.05) by 2.3% (18.87 ± 0.97-18.44 ± 1.06 seconds) and RST by 4.3% postintervention in the HIT group only. Baseline RST fatigue index was 7.0 ± 2.9 and 6.2 ± 5.0% in HIT and CON, respectively, but was lowered (p ≤ 0.05) to 2.7 ± 3.0% posttraining in HIT and remained unaltered in CON (5.5 ± 5.0%). In HIT, Yo-Yo IR2 and Yo-Yo IR1 performance improved by 12.6 and 18.3% postintervention, respectively, with greater (p ≤ 0.05) Yo-yo IR1 change scores than in CON. In conclusion, additional high-intensity in-season training performed as interval running improved agility, repeated sprint ability, and high-intensity intermittent exercise performance in elite women volleyball players.

  5. Innovative use of controlled availability fertilizers with high performance for intensive agriculture and environmental conservation

    Institute of Scientific and Technical Information of China (English)

    Sadao SHOJI

    2005-01-01

    A variety of slow release fertilizers, controlled release (availability) fertilizers (CAFs),and stability fertilizers have been developed in response to the serious drawbacks of the conventional fertilizers since the early 1960's. Of these fertilizers, CAFs which are coated with resin are consumed in the largest quantity in the world. Selecting CAFs with higher performance, the author will discuss about: 1) Innovation of agro-technologies for various field crops including new concepts of fertilizer application, 2) high yielding of field crops, 3) enhancing quality and safety of farm products, and 4) controlling the adverse effect of intensive agriculture on the environment.

  6. A Novel Dual-Electrode Plug to Achieve Intensive Electric Field for High Performance Ignition

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2013-01-01

    Full Text Available A thorough analysis of electric field is carried out so as to verify that a novel dual-electrode plug can build intensive electric field and can improve the main drawbacks of feeble electric field and low ignition efficiency of the traditional plug. With intensive electric field, the proposed novel plug can achieve high performance ignition, resulting in fuel saving and exhaust reduction. Gauss law is applied for electric field analysis to show that intensive electric field can be built by the novel plug. Then, according to Faraday law a lower-voltage ignition feature accomplished by the plug is discussed. Compared with traditional plug, the novel dual-electrode plug has the following advantages. (1 Much higher energy density is built between the plug electrodes, lowering ignition voltage requirement. (2 Electromagnetic interference (EMI problem caused by high ignition voltage is readily resolved. (3 Ignition time delay can be improved. (4 The feature to save fuel consuming is achieved. (5 The exhaust of CO and HC is reduced significantly. Practical measurements are fulfilled to validate the electric field analysis and to demonstrate the features of the proposed dual-electrode plug.

  7. Repeated sprint swimming performance after low- or high-intensity active and passive recoveries.

    Science.gov (United States)

    Toubekis, Argyris G; Adam, Georgios V; Douda, Helen T; Antoniou, Panagiotis D; Douroundos, Ioannis I; Tokmakidis, Savvas P

    2011-01-01

    The purpose of this study was to examine the effects on sprint swimming performance after low- and high-intensity active recovery (AR) as compared to passive recovery. Ten male competitive swimmers (age: 17.9 ± 2.3 years; body mass: 73.2 ± 4.0 kg; height: 1.81 ± 0.04 m, 100-m best time: 54.90 ± 1.96 seconds) performed 8 × 25-m sprints with 120-second rest intervals followed by a 50-m sprint 6 minutes later. During the 120-second and the 6-minute interval periods swimmers rested passively (PAS) or swam at an intensity of 40% (ACT40; 36 ± 8% of the V(O2)max) and 60% (ACT60; 59 ± 7% of the V(O2)max) of their individual 100-m velocity. Performance time of the 8 × 25-m after ACT60 was slower compared with PAS and ACT40, but no difference was observed between ACT40 and PAS conditions (PAS: 12.15 ± 0.48, ACT40: 12.23 ± 0.54, ACT60: 12.35 ± 0.57 seconds, p sprint was no different between conditions (PAS: 26.45 ± 0.91; ACT40: 26.30 ± 1.18; ACT60: 26.21 ± 1.19 seconds; p > 0.05). Blood lactate concentration was not different between PAS, ACT40, and ACT60 after the 8 × 25-m and the 50-m sprints (p > 0.05). Passive recovery, or low intensity of AR (40% of the 100-m velocity), is advised to maintain repeated 25-m sprint swimming performance when a 2-minute interval period is provided. Active recovery at an intensity corresponding to 60% of the 100-m velocity decreases performance during the 25-m repeated sprints without affecting the performance time on a subsequent longer duration sprint (i.e., 50 m).

  8. Five Weeks of Sprint and High-Intensity Interval Training Improves Paddling Performance in Adolescent Surfers.

    Science.gov (United States)

    Farley, Oliver R L; Secomb, Josh L; Parsonage, Joanna R; Lundgren, Lina E; Abbiss, Chris R; Sheppard, Jeremy M

    2016-09-01

    Farley, ORL, Secomb, JL, Parsonage, JR, Lundgren, LE, Abbiss, CR, and Sheppard, JM. Five weeks of sprint and high-intensity interval training improves paddling performance in adolescent surfers. J Strength Cond Res 30(9): 2446-2452, 2016-The purpose of our study was to examine the effects of sprint interval training (SIT; 10 seconds) and high-intensity interval training (HIT; 30 seconds) on surfing athletes paddling performance (400-m time trial and repeat-sprint paddle performance). Twenty-four competitive adolescent surfers (19 male, 5 female; age = 14.4 ± 1.3 years, mass: 50.1 ± 10.7 kg, and stature: 159.9 ± 10.3 cm) were assigned to perform either 5 weeks of SIT and HIT. Participants completed a repeated-sprint paddle ability test (RSPT, 15-m surfboard sprint paddle initiated every 40 seconds × 10 bouts) and 400-m endurance surfboard paddle time trial before and after training. High-intensity interval training decreased the total time to complete the 400 m by 15.8 ± 16.1 seconds (p = 0.03), and SIT decreased the total time to complete the RSPT by 6.5 ± 4.3 seconds (p = 0.02). Fatigue index during the RSPT (first-slowest effort) was lower after HIT and SIT (p ≤ 0.001 and p = 0.02, respectively). There were no significant differences in performance changes in the 400 m (total time) and RSPT (total time, fastest 15 m time, and peak velocity) between HIT and SIT. Our study indicates that HIT and SIT may be implemented to the training program of surfers to improve aerobic and repeat-sprint paddle ability, both of which are identified as key aspects of the sport. In addition, these findings indicate that 400-m paddle and RSPT can discriminate between aerobic and anaerobic training adaptations, with aerobic gains likely from HIT and anaerobic gains from SIT.

  9. Jump-Squat Performance and Its Relationship With Relative Training Intensity in High-Level Athletes.

    Science.gov (United States)

    Jiménez-Reyes, Pedro; Pareja-Blanco, Fernando; Balsalobre-Fernández, Carlos; Cuadrado-Peñafiel, Víctor; Ortega-Becerra, Manuel A; González-Badillo, Juan J

    2015-11-01

    To examine the relationship between the relative load in full squats and the height achieved in jump-squat (JS) exercises and to determine the load that maximizes the power output of high-level athletes. Fifty-one male high-level track-and-field athletes (age 25.2 ± 4.4 y, weight 77. ± 6.2 kg, height 179.9 ± 5.6 cm) who competed in sprinting and jumping events took part in the study. Full-squat 1-repetition-maximum (1-RM) and JS height (JH) with loads from 17 to 97 kg were measured in 2 sessions separated by 48 h. Individual regression analyses showed that JH (R2 = .992 ± .005) and the jump decrease (JD) that each load produced with respect to the unloaded countermovement jump (CMJ) (R2 = .992 ± 0.007) are highly correlated with the full-squat %1-RM, which means that training intensities can be prescribed using JH and JD values. The authors also found that the load that maximizes JS's power output was 0%RM (ie, unloaded CMJ). These results highlight the close relationship between JS performance and relative training intensity in terms of %1-RM. The authors also observed that the load that maximizes power output was 0%1-RM. Monitoring jump height during JS training could help coaches and athletes determine and optimize their training loads.

  10. A MOTIVATIONAL MUSIC AND VIDEO INTERVENTION IMPROVES HIGH-INTENSITY EXERCISE PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Martin J. Barwood

    2009-09-01

    Full Text Available Music and video are utilised by recreational gym users to enhance their exercise experience. Music and video have not been investigated for their combined ergogenic effect during high intensity exercise. To induce fatigue, this study was performed in warm (~26°C, moist conditions (~50%RH. Six, non-acclimated, male participants took part in the study. Each participant completed three 30-minute exercise bouts on a motorised treadmill under three counterbalanced conditions on separate days: control (CON, motivational music plus video intervention (M, non-motivational intervention (NM. They completed a warm-up (5 km·h-1 [5 minutes], 9km·h-1 [10 minutes] followed by a maximal effort run (15 minutes. Participants did not receive any feedback of time elapsed, distance run or speed. Measures: Distance covered (metres, heart rate, blood lactate accumulation (Blac and ratings of perceived exertion (RPE. Participants in the M condition ran significantly further than in the NM (M: 3524 [388]metres; NM: 3110 [561]metres; CON: 3273 [458]metres and CON conditions, accumulated more Blac, but did not increase their peak RPE rating (p < 0.05. The M intervention improved tolerance of high intensity exercise in warm conditions. It was proposed that a change in attentional processing from internal (physical sensations to external perspective (music and video may have facilitated this improvement. These findings have strong implications for improving health, fitness and engagement in gym-based exercise programs

  11. A Lightweight, High-performance I/O Management Package for Data-intensive Computing

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jun

    2011-06-22

    Our group has been working with ANL collaborators on the topic bridging the gap between parallel file system and local file system during the course of this project period. We visited Argonne National Lab -- Dr. Robert Ross's group for one week in the past summer 2007. We looked over our current project progress and planned the activities for the incoming years 2008-09. The PI met Dr. Robert Ross several times such as HEC FSIO workshop 08, SC08 and SC10. We explored the opportunities to develop a production system by leveraging our current prototype to (SOGP+PVFS) a new PVFS version. We delivered SOGP+PVFS codes to ANL PVFS2 group in 2008.We also talked about exploring a potential project on developing new parallel programming models and runtime systems for data-intensive scalable computing (DISC). The methodology is to evolve MPI towards DISC by incorporating some functions of Google MapReduce parallel programming model. More recently, we are together exploring how to leverage existing works to perform (1) coordination/aggregation of local I/O operations prior to movement over the WAN, (2) efficient bulk data movement over the WAN, (3) latency hiding techniques for latency-intensive operations. Since 2009, we start applying Hadoop/MapReduce to some HEC applications with LANL scientists John Bent and Salman Habib. Another on-going work is to improve checkpoint performance at I/O forwarding Layer for the Road Runner super computer with James Nuetz and Gary Gridder at LANL. Two senior undergraduates from our research group did summer internships about high-performance file and storage system projects in LANL since 2008 for consecutive three years. Both of them are now pursuing Ph.D. degree in our group and will be 4th year in the PhD program in Fall 2011 and go to LANL to advance two above-mentioned works during this winter break. Since 2009, we have been collaborating with several computer scientists (Gary Grider, John bent, Parks Fields, James Nunez, Hsing

  12. Predicting changes in high-intensity intermittent running performance with acute responses to short jump rope workouts in children

    National Research Council Canada - National Science Library

    Buchheit, Martin; Rabbani, Alireza; Beigi, Hamid Taghi

    2014-01-01

    The aims of the present study were to 1) examine whether individual HR and RPE responses to a jump rope workout could be used to predict changes in high-intensity intermittent running performance in young athletes, and 2...

  13. Carbohydrate-gel supplementation and endurance performance during intermittent high-intensity shuttle running.

    Science.gov (United States)

    Patterson, Stephen D; Gray, Susan C

    2007-10-01

    The aim of this study was to investigate the effects of a carbohydrate (CHO) gel on performance after prolonged intermittent high-intensity shuttle running. Seven male soccer players performed 2 exercise trials, 7 d apart. On each occasion, participants completed five 15-min periods of intermittent variable-speed running, interspersed with periods of walking (Part A), followed by an intermittent run to exhaustion (Part B). Participants consumed either a CHO gel or placebo (PLA) immediately before exercise (0.89 mL/kg body mass [BM]) and every 15 min thereafter (0.35 mL/kg BM). In addition, water was consumed at a rate of 5 mL/kg BM before and 2 mL/kg BM every 15 min during exercise. Blood glucose levels were higher (P < 0.05) at 15, 30, and 60 min of exercise and at exhaustion in CHO than in PLA. During Part B, run time to exhaustion was longer (P < 0.05) in the CHO trial (CHO 6.1 +/- 1.3 min vs. PLA 4.2 +/- 1.2 min). These results indicate that ingesting a CHO gel, along with water, improves performance after prolonged intermittent running in healthy male subjects, possibly by maintaining blood glucose levels during exercise.

  14. Psychological skills training as a way to enhance an athlete's performance in high-intensity sports.

    Science.gov (United States)

    Birrer, D; Morgan, G

    2010-10-01

    The importance of psychological skills training (PST) in the development of athletic performance is widely recognized. This paper is a comprehensive review of PST in elite sports, with a special focus on high-intensity sports (HIS). The reviewed literature showed a lack of convincing evidence and theoretical underpinning concerning traditional psychological skills to enhance performance in HIS. Therefore, a model with three conceptual levels (psychological demands, skills and techniques) is presented. The model facilitates the identification of the psychological demands of a specific sport, which in turn enables distinguishing which psychological skills are required. This allows an expert to choose psychological techniques to improve the athlete's psychological skill. Considerations based on our model and the limited HIS-related literature available revealed self-skills, personal development and life skills, arousal-regulation skills, volitional skills, motivational skills and recovery skills as the most important skills to address in order to enhance performance. Development of harmonious passion, in-practice integration of volitional strategies, use of associative attentional techniques, pain management techniques, use of the mindfulness-acceptance approach and the facilitative interpretation of cognitive and somatic sensations are regarded as suitable to meet the psychological demands of HIS. They are recommended for systematic application by athletes and coaches. © 2010 John Wiley & Sons A/S.

  15. High Intensity Interval Training (HIIT) improves physical performance and frailty in aged mice.

    Science.gov (United States)

    Seldeen, Kenneth Ladd; Lasky, Ginger; Leiker, Merced Maria; Pang, Manhui; Personius, Kirkwood Ely; Troen, Bruce Robert

    2017-06-17

    Sarcopenia and frailty are highly prevalent in older individuals, increasing the risk of disability and loss of independence. High intensity interval training (HIIT) may provide a robust intervention for both sarcopenia and frailty by achieving both strength and endurance benefits with lower time commitments than other exercise regimens. To better understand the impacts of HIIT during aging, we compared 24-month-old C57BL/6J sedentary mice with those that were administered 10-minute uphill treadmill HIIT sessions three times per week over 16 weeks. Baseline and endpoint assessments included body composition, physical performance, and frailty based upon criteria from the Fried physical frailty scale. HIIT trained mice demonstrated dramatic improvement in grip strength (HIIT 10.9% versus -3.9% in sedentary mice), treadmill endurance (32.6% versus -2.0%), and gait speed (107.0% versus 39.0%). Muscles from HIIT mice also exhibited greater mass, larger fiber size, and an increase in mitochondrial biomass. Furthermore, HIIT exercise showed dramatic reduction in frailty scores in 5 of 6 mice that were frail or pre-frail at baseline, with 4 ultimately becoming non-frail. The uphill treadmill HIIT exercise sessions were well tolerated by aged mice and led to dramatic performance gains, improvement in underlying muscle physiology, and reduction in frailty. Published by Oxford University Press on behalf of The Gerontological Society of America 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  16. High-intensity intermittent exercise and its effects on heart rate variability and subsequent strength performance

    Directory of Open Access Journals (Sweden)

    Valéria Leme Gonçalves Panissa

    2016-03-01

    Full Text Available PRUPOSE: To investigate the effects of a 5-km high-intensity interval exercise (HIIE on heart rate variability (HRV and subsequent strength performance. METHODS: nine trained males performed a control session composed of a half-squat strength exercise (4 x 80% of one repetition maximum – 1RM in isolation and 30-min, 1-, 4-, 8- and 24-h after an HIIE (1-min at the velocity peak:1-min passive recovery. All experimental sessions were performed on different days. The maximum number of repetitions and total weight lifted during the strength exercise were registered in all conditions; in addition, prior to each session, HRV were assessed [beat-to-beat intervals (RR and log-transformed of root means square of successive differences in the normal-to-normal intervals (lnRMSSD]. RESULTS: Performance in the strength exercise dropped at 30-min (31% and 1-h (19% post-HIIE concomitantly with lower values of RR (781±79 ms; 799±134 ms, respectively in the same recovery intervals compared to the control (1015±197 ms. Inferential analysis did not detect any effect of condition on lnRMSSD, however, values were lower after 30-min (3.5±0.4 ms and 1-h (3.3±0.5 ms with moderate and large effect sizes (0.9 and 1.2, respectively compared with the control condition (3.9±0.4 ms. CONCLUSION: Both RR and lnRMSSD seem to be associated with deleterious effects on strength performance, although further studies should be conducted to clarify this association.

  17. The effects of creatine pyruvate and creatine citrate on performance during high intensity exercise

    Directory of Open Access Journals (Sweden)

    Purpura Martin

    2008-02-01

    Full Text Available Abstract Background A double-blind, placebo-controlled, randomized study was performed to evaluate the effect of oral creatine pyruvate (Cr-Pyr and creatine citrate (Cr-Cit supplementation on exercise performance in healthy young athletes. Methods Performance during intermittent handgrip exercise of maximal intensity was evaluated before (pretest and after (posttest 28 days of Cr-Pyr (5 g/d, n = 16, Cr-Cit (5 g/d, n = 16 or placebo (pla, 5 g/d, n = 17 intake. Subjects performed ten 15-sec exercise intervals, each followed by 45 sec rest periods. Results Cr-Pyr (p Conclusion It is concluded that four weeks of Cr-Pyr and Cr-Cit intake significantly improves performance during intermittent handgrip exercise of maximal intensity and that Cr-Pyr might benefit endurance, due to enhanced activity of the aerobic metabolism.

  18. Multimodal high-intensity interval training increases muscle function and metabolic performance in females.

    Science.gov (United States)

    Buckley, Stephanie; Knapp, Kelly; Lackie, Amy; Lewry, Colin; Horvey, Karla; Benko, Chad; Trinh, Jason; Butcher, Scotty

    2015-11-01

    High-intensity interval training (HIIT) is a time-efficient method of improving aerobic and anaerobic power and capacity. In most individuals, however, HIIT using modalities such as cycling, running, and rowing does not typically result in increased muscle strength, power, or endurance. The purpose of this study is to compare the physiological outcomes of traditional HIIT using rowing (Row-HIIT) with a novel multimodal HIIT (MM-HIIT) circuit incorporating multiple modalities, including strength exercises, within an interval. Twenty-eight recreationally active women (age 24.7 ± 5.4 years) completed 6 weeks of either Row-HIIT or MM-HIIT and were tested on multiple fitness parameters. MM-HIIT and Row-HIIT resulted in similar improvements (p HIIT group had significant (p HIIT group had no increase in any muscle performance variable (p values 0.33-0.90). Post-training, 1-repetition maximum (1RM) squat (64.2 ± 13.6 vs. 45.8 ± 16.2 kg, p = 0.02), 1RM press (33.2 ± 3.8 vs. 26.0 ± 9.6 kg, p = 0.01), and squat endurance (23.9 ± 12.3 vs. 10.2 ± 5.6 reps, p HIIT group than in the Row-HIIT group. MM-HIIT resulted in similar aerobic and anaerobic adaptations but greater muscle performance increases than Row-HIIT in recreationally active women.

  19. The Effect of Caffeine on Repeat-High-Intensity-Effort Performance in Rugby League Players.

    Science.gov (United States)

    Wellington, Brandon M; Leveritt, Michael D; Kelly, Vincent G

    2017-02-01

    Repeat-high-intensity efforts (RHIEs) have recently been shown to occur at critical periods of rugby league matches. To examine the effect that caffeine has on RHIE performance in rugby league players. Using a double-blind, placebo-controlled, crossover design, 11 semiprofessional rugby league players (age 19.0 ± 0.5 y, body mass 87.4 ± 12.9 kg, height 178.9 ± 2.6 cm) completed 2 experimental trials that involved completing an RHIE test after either caffeine (300 mg caffeine) or placebo (vitamin H) ingestion. Each trial consisted of 3 sets of 20-m sprints interspersed with bouts of tackling. During the RHIE test, 20-m-sprint time, heart rate (HR), rating of perceived exertion (RPE), and blood lactate were measured. Total time to complete the nine 20-m sprints during the caffeine condition was 1.0% faster (28.46 ± 1.4 s) than during the placebo condition (28.77 ± 1.7 s) (ES = 0.18, 90%CI -0.7 to 0.1 s). This resulted in a very likely chance of caffeine being of benefit to RHIE performance (99% likely to be beneficial). These improvements were more pronounced in the early stages of the test, with a 1.3%, 1.0%, and 0.9% improvement in sprint performance during sets 1, 2, and 3 respectively. There was no significant difference in RPE across the 3 sets (P = .47, 0.48, 1.00) or mean HR (P = .36), maximal HR (P = .74), or blood lactate (P = .50) between treatment conditions. Preexercise ingestion of 300 mg caffeine produced practically meaningful improvements in RHIE performance in rugby league players.

  20. Sodium bicarbonate intake improves high-intensity intermittent exercise performance in trained young men

    DEFF Research Database (Denmark)

    Krustrup, Peter; Ermidis, Georgios; Mohr, Magni

    2015-01-01

    Background Sodium bicarbonate intake has been shown to improve exercise tolerance, but the effects on high-intensity intermittent exercise are less clear. Thus, the aim of the present study was to determine the effect of sodium bicarbonate intake on Yo-Yo intermittent recovery level 2 test......) prior intake of sodium bicarbonate (0.4 g · kg−1 body weight). Heart rate and rating of perceived exertion (RPE) were measured during the test and venous blood samples were taken frequently. Results Yo-Yo IR2 performance was 14 % higher (P = 0.04) in SBC than in CON (735 ± 61 vs 646 ± 46 m, respectively....... Peak heart rate reached at exhaustion was 197 ± 3 and 195 ± 3 bpm in SBC and CON, respectively, with no difference between conditions. RPE was 7 % lower (P = 0.003) in SBC than in CON after 440 m, but similar at exhaustion (19.3 ± 0.2 and 19.5 ± 0.2). Conclusion In conclusion, high...

  1. A numerical investigation of the performance of sound intensity probes at high frequencies

    DEFF Research Database (Denmark)

    Cutanda, Vicente; Juhl, Peter Møller; Jacobsen, Finn

    1996-01-01

    The influence of diffraction on the performance of sound intensity probes has been examined using a boundary element model of an axisymmetric 'two-microphone' probe with the microphones in the usual 'face-to-face' arrangement. On the basis of calculations for a variety of sound field conditions a...

  2. Effects of high-intensity intermittent priming on physiology and cycling performance.

    Science.gov (United States)

    McIntyre, Jordan P R; Kilding, Andrew E

    2015-01-01

    The pre-event warm-up or "priming" routine for optimising cycling performance is not well-defined or uniform to a specific event. We aimed to determine the effects of varying the intensity of priming on 3 km cycling performance. Ten endurance-trained male cyclists completed four 3 km time-trials (TT) on four separate occasions, each preceded by a different priming strategy including "self-selected" priming and three intermittent priming strategies incorporating 10 min of constant-load cycling followed by 5 × 10 s bouts of varying relative intensity (100% and 150% of peak aerobic power, Wpeak, and all-out priming). The self-selected priming trial (379 ± 44 W) resulted in similar mean power during the 3 km TT to intermittent priming at 100% (376 ± 45 W; -0.7%; unclear) and 150% (374 ± 48 W; -1.5%, unclear) of Wpeak, but significantly greater than all-out priming (357 ± 45 W; -5.8%, almost certainly harmful). Differences between intermittent and self-selected priming existed with regards to heart rate (6.2% to 11.5%), blood lactate (-22.9% to 125%) and VO2 kinetics (-22.9% to 8.2%), but these were not related to performance outcomes. In conclusion, prescribed intermittent priming strategies varying in intensity did not substantially improve 3 km TT performance compared to self-selected priming.

  3. CTA in acute stroke: short intensive training intervention is highly effective in improving radiologists' performance.

    Science.gov (United States)

    Cora, E A; Ford, G A; Flynn, D; Gonsalves, P; White, P

    2017-10-01

    To determine whether focussed radiology training in reporting stroke computed tomography angiography (CTA) improved diagnostic performance of general radiology specialty trainees staffing regional on call rotas. A validated case archive (VCA) consisting of 50 hyperacute stroke CTA cases was developed for a full day course on CTA interpretation. Training days were organised ensuring all local trainees had a chance to attend. The rate of major and minor amendments by neuroradiology consultants were reviewed in 252 on-call radiology trainee reports. Before training, radiology trainees had a total discrepancy (reporting error) rate of 37%: 12% major, 25% minor. Following CTA training, the total discrepancy rate was not significantly reduced (34%) but there was a substantial reduction in major discrepancies to 4% (p=0.037; odds ratio=3.30, 95% confidence interval [CI]: 1.08 to 10.12). An intensive training course based on a hyperacute stroke VCA significantly reduced major discrepancies in stroke CTA interpretation for radiology trainees. The ability of radiology trainees to recognise large vessel occlusions and other significant findings improved. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  4. Effect of strength and high-intensity training on jumping, sprinting, and intermittent endurance performance in prepubertal soccer players.

    Science.gov (United States)

    Ferrete, Carlos; Requena, Bernardo; Suarez-Arrones, Luís; de Villarreal, Eduardo Sáez

    2014-02-01

    The purpose of this study was to examine the effects of a 26-week on-field combined strength and high-intensity training on the physical performance capacity among prepubertal soccer players who were undertaking a competitive phase of training. Twenty-four prepubertal soccer players between the age of 8 and 9 years were randomly assigned to 2 groups: a control (C; n = 13) and an experimental group (S; n = 11). Both groups performed an identical soccer-training program, whereas the S group also performed combined strength and high-intensity training before the soccer-specific training. The 15-m sprint time (seconds), countermovement jump (CMJ) displacement, Yo-Yo intermittent endurance test (Yo-Yo IE), and Sit and Reach flexibility were each measured before (baseline) and after 9 (T2), 18 (T3), and 26 weeks (posttest) of training. There were no significant differences between the groups in any of the variables tested at baseline. After 26 weeks, significant improvements were found in the CMJ (6.72%; effect size [ES] = 0.37), Yo-Yo IE (49.57%, ES = 1.39), and Flexibility (7.26%; ES = 0.37) variables for the S group. Conversely, significant decreases were noted for the CMJ (-10.82%; ES = 0.61) and flexibility (-13.09%; ES = 0.94) variables in the C group. A significant negative correlation was found between 15-m sprint time and CMJ (r = -0.77) and Yo-Yo IE (r = -0.77) in the S group. Specific combined strength and high-intensity training in prepubertal soccer players for 26 weeks produced a positive effect on performance qualities highly specific to soccer. Therefore, we propose modifications to current training methodology for prepubertal soccer players to include strength and high-intensity training for athlete preparation in this sport.

  5. Predicting changes in high-intensity intermittent running performance with acute responses to short jump rope workouts in children.

    Science.gov (United States)

    Buchheit, Martin; Rabbani, Alireza; Beigi, Hamid Taghi

    2014-09-01

    The aims of the present study were to 1) examine whether individual HR and RPE responses to a jump rope workout could be used to predict changes in high-intensity intermittent running performance in young athletes, and 2) examine the effect of using different methods to determine a smallest worthwhile change (SWC) on the interpretation of group-average and individual changes in the variables. Before and after an 8-week high-intensity training program, 13 children athletes (10.6 ± 0.9 yr) performed a high-intensity running test (30-15 Intermittent Fitness Test, VIFT) and three jump rope workouts, where HR and RPE were collected. The SWC was defined as either 1/5(th) of the between-subjects standard deviation or the variable typical error (CV). After training, the large ~9% improvement in VIFT was very likely, irrespective of the SWC. Standardized changes were greater for RPE (very likely-to-almost certain, ~30-60% changes, ~4-16 times >SWC) than for HR (likely-to-very likely, ~2-6% changes, ~1-6 times >SWC) responses. Using the CV as the SWC lead to the smallest and greatest changes for HR and RPE, respectively. The predictive value for individual performance changes tended to be better for HR (74-92%) than RPE (69%), and greater when using the CV as the SWC. The predictive value for no-performance change was low for both measures (jump rope workouts can predict substantial improvements in high-intensity running performance at the individual level. Using the CV of test measures as the SWC might be the better option. Key pointsDecreased HR and RPE responses to short jump rope workouts can be confidently used to track improvements in high-intensity intermittent running performance in children familiarized with this exercise mode. Rope jumping is a particularly convenient exercise, since it can be performed in a restricted space and allows the testing of a large number of athletes simultaneously.We recommend using the CV of the measures (i.e., 3 and 4% for HR and RPE

  6. [Performance enhancement by carbohydrate intake during sport: effects of carbohydrates during and after high-intensity exercise].

    Science.gov (United States)

    Beelen, Milou; Cermak, Naomi M; van Loon, Luc J C

    2015-01-01

    Endogenous carbohydrate availability does not provide sufficient energy for prolonged moderate to high-intensity exercise. Carbohydrate ingestion during high-intensity exercise can therefore enhance performance.- For exercise lasting 1 to 2.5 hours, athletes are advised to ingest 30-60 g of carbohydrates per hour.- Well-trained endurance athletes competing for longer than 2.5 hours at high intensity can metabolise up to 90 g of carbohydrates per hour, provided that a mixture of glucose and fructose is ingested.- Athletes participating in intermittent or team sports are advised to follow the same strategies but the timing of carbohydrate intake depends on the type of sport.- If top performance is required again within 24 hours after strenuous exercise, the advice is to supplement endogenous carbohydrate supplies quickly within the first few hours post-exercise by ingesting large amounts of carbohydrate (1.2 g/kg/h) or a lower amount of carbohydrate (0.8 g/kg/h) with a small amount of protein (0.2-0.4 g/kg/h).

  7. Effects of Low-Volume, High-Intensity Training on Performance in Competitive Swimmers: A Systematic Review.

    Science.gov (United States)

    Nugent, Frank J; Comyns, Thomas M; Burrows, Emma; Warrington, Giles D

    2017-03-01

    Nugent, FJ, Comyns, TM, Burrows, E, and Warrington, GD. Effects of low-volume, high-intensity training on performance in competitive swimmers: a systematic review. J Strength Cond Res 31(3): 837-847, 2017-The purpose of this systematic review was to examine the extent and quality of the current research literature to determine the effects of low-volume, high-intensity training (HIT) on physiological performance and swimming performance in competitive swimmers. The methodology followed the preferred reporting items for systematic review and meta-analysis protocol. A search of relevant databases and conference proceedings was performed until December 2015. The inclusion criteria were (a) competitive swimmers, (b) ≥4 weeks HIT intervention, (c) comparison group had to involve a higher training volume, (d) outcome measures of physiological and swimming performance, and (e) all experimental study designs. Quality assessment was performed using the Quality Index checklist. Results indicate that of the 538 studies retrieved, 7 studies met the inclusion criteria. Six of the 7 studies found that an HIT intervention resulted in significant improvements in physiological performance. Four of the 7 studies found that HIT resulted in significant improvements in swimming performance, whereas none of the 7 studies resulted in a reduction in physiological or swimming performance. Despite the positive findings of this review, the short study duration is a limitation to a number of studies. The current evidence on the effects of HIT on performance is promising; however, it is difficult to draw accurate conclusions until further research has been conducted.

  8. Combined inhalation of beta2 -agonists improves swim ergometer sprint performance but not high-intensity swim performance.

    Science.gov (United States)

    Kalsen, A; Hostrup, M; Bangsbo, J; Backer, V

    2014-10-01

    There is a high prevalence of asthma and airway hyperresponsiveness (AHR) in elite athletes, which leads to a major use of beta2 -agonists. In a randomized double-blinded crossover study, we investigated the effects of combined inhalation of beta2 -agonists (salbutamol, formoterol, and salmeterol), in permitted doses within the World Anti-Doping Agency 2013 prohibited list, in elite swimmers with (AHR, n = 13) or without (non-AHR, n = 17) AHR. Maximal voluntary isometric contraction of m. quadriceps (MVC), sprint performance on a swim ergometer and performance in an exhaustive swim test at 110% of VO2max were determined. Venous plasma interleukin-6 (IL-6) and interleukin-8 (IL-8) were measured post-exercise. No improvement was observed in the exhaustive swim test, but swim ergometer sprint time was improved (P swim performance in elite swimmers. However, swim ergometer sprint performance and MVC were increased, which should be considered when making future anti-doping regulations.

  9. A High Intensity Interval Training (HIIT)-Based Running Plan Improves Athletic Performance by Improving Muscle Power.

    Science.gov (United States)

    García-Pinillos, Felipe; Cámara-Pérez, Jose C; Soto-Hermoso, Víctor M; Latorre-Román, Pedro Á

    2017-01-01

    García-Pinillos, F, Cámara-Pérez, JC, Soto-Hermoso, VM, and Latorre-Román, PÁ. A High Intensity Interval Training (HIIT)-based running plan improves athletic performance by improving muscle power. J Strength Cond Res 31(1): 146-153, 2017-This study aimed to examine the effect of a 5-week high-intensity intermittent training (HIIT)-based running plan on athletic performance and to compare the physiological and neuromuscular responses during a sprint-distance triathlon before and after the HIIT period. Thirteen triathletes were matched into 2 groups: the experimental group (EG) and the control group (CG). The CG was asked to maintain their normal training routines, whereas the EG maintained only their swimming and cycling routines and modified their running routine. Participants completed a sprint-distance triathlon before (pretest) and after (posttest) the intervention period. In both pretest and posttest, the participants performed 4 jumping tests: before the race (baseline), postswim, postcycling, and postrun. Additionally, heart rate was monitored (HRmean), whereas rate of perceived exertion (RPE) and blood lactate accumulation (BLa) were registered after the race. No significant differences (p ≥ 0.05) between groups were found before HIIT intervention (at pretest). Significant group-by-training interactions were found in vertical jumping ability and athletic performance: the EG improved jumping performance (∼6-9%, p ≤ 0.05, effect size (ES) > 0.7), swimming performance (p = 0.013, ES = 0.438), and running time (p = 0.001, ES = 0.667) during the competition, whereas the CG remained unchanged (p ≥ 0.05, ES HIIT-based running plan combined with the high training volumes of these triathletes in swimming and cycling improved athletic performance during a sprint-distance triathlon. This improvement may be due to improved neuromuscular characteristics that were transferred into improved muscle power and work economy.

  10. Carbohydrate Mouth Rinsing Enhances High Intensity Time Trial Performance Following Prolonged Cycling

    Science.gov (United States)

    Luden, Nicholas D.; Saunders, Michael J.; D’Lugos, Andrew C.; Pataky, Mark W.; Baur, Daniel A.; Vining, Caitlin B.; Schroer, Adam B.

    2016-01-01

    There is good evidence that mouth rinsing with carbohydrate (CHO) solutions can enhance endurance performance (≥30 min). The impact of a CHO mouth rinse on sprint performance has been less consistent, suggesting that CHO may confer benefits in conditions of ‘metabolic strain’. To test this hypothesis, the current study examined the impact of late-exercise mouth rinsing on sprint performance. Secondly, we investigated the effects of a protein mouth rinse (PRO) on performance. Eight trained male cyclists participated in three trials consisting of 120 min of constant-load cycling (55% Wmax) followed by a 30 km computer-simulated time trial, during which only water was provided. Following 15 min of muscle function assessment, 10 min of constant-load cycling (3 min at 35% Wmax, 7 min at 55% Wmax) was performed. This was immediately followed by a 2 km time trial. Subjects rinsed with 25 mL of CHO, PRO, or placebo (PLA) at min 5:00 and 14:30 of the 15 min muscle function phase, and min 8:00 of the 10-min constant-load cycling. Magnitude-based inferential statistics were used to analyze the effects of the mouth rinse on 2-km time trial performance and the following physiological parameters: Maximum Voluntary Contract (MVC), Rating of Perceived Exertion (RPE), Heart Rate (HR), and blood glucose levels. The primary finding was that CHO ‘likely’ enhanced performance vs. PLA (3.8%), whereas differences between PRO and PLA were unclear (0.4%). These data demonstrate that late-race performance is enhanced by a CHO rinse, but not PRO, under challenging metabolic conditions. More data should be acquired before this strategy is recommended for the later stages of cycling competition under more practical conditions, such as when carbohydrates are supplemented throughout the preceding minutes/hours of exercise. PMID:27657117

  11. Exploiting Data Intensive Applications on High Performance Computers to Unlock Australia's Landsat Archive

    Science.gov (United States)

    Purss, Matthew; Lewis, Adam; Edberg, Roger; Ip, Alex; Sixsmith, Joshua; Frankish, Glenn; Chan, Tai; Evans, Ben; Hurst, Lachlan

    2013-04-01

    Australia's Earth Observation Program has downlinked and archived satellite data acquired under the NASA Landsat mission for the Australian Government since the establishment of the Australian Landsat Station in 1979. Geoscience Australia maintains this archive and produces image products to aid the delivery of government policy objectives. Due to the labor intensive nature of processing of this data there have been few national-scale datasets created to date. To compile any Earth Observation product the historical approach has been to select the required subset of data and process "scene by scene" on an as-needed basis. As data volumes have increased over time, and the demand for the processed data has also grown, it has become increasingly difficult to rapidly produce these products and achieve satisfactory policy outcomes using these historic processing methods. The result is that we have been "drowning in a sea of uncalibrated data" and scientists, policy makers and the public have not been able to realize the full potential of the Australian Landsat Archive and its value is therefore significantly diminished. To overcome this critical issue, the Australian Space Research Program has funded the "Unlocking the Landsat Archive" (ULA) Project from April 2011 to June 2013 to improve the access and utilization of Australia's archive of Landsat data. The ULA Project is a public-private consortium led by Lockheed Martin Australia (LMA) and involving Geoscience Australia (GA), the Victorian Partnership for Advanced Computing (VPAC), the National Computational Infrastructure (NCI) at the Australian National University (ANU) and the Cooperative Research Centre for Spatial Information (CRC-SI). The outputs from the ULA project will become a fundamental component of Australia's eResearch infrastructure, with the Australian Landsat Archive hosted on the NCI and made openly available under a creative commons license. NCI provides access to researchers through significant HPC

  12. Scapular muscle activity from selected strengthening exercises performed at low and high intensity

    DEFF Research Database (Denmark)

    Andersen, Christoffer H; Zebis, Mette K; Saervoll, Charlotte

    2012-01-01

    A balanced level of muscle strength between the different parts of the scapular muscles is important to optimize performance and prevent injuries in athletes. Emerging evidence suggests that many athletes lack balanced strength in the scapular muscles. Evidence based recommendations are important...... practical implications for exercise prescription for optimal shoulder function. For example, both workers with neck pain and athletes at risk of shoulder impingement (e.g. overhead sports) should perform push-up plus and press-up to specifically strengthen the serratus anterior and lower trapezius....

  13. Low cadence interval training at moderate intensity does not improve cycling performance in highly trained veteran cyclists

    Directory of Open Access Journals (Sweden)

    Morten eKristoffersen

    2014-01-01

    Full Text Available Purpose: The aim of the present study was to investigate effects of low cadence training at moderate intensity on aerobic capacity, cycling performance, gross efficiency, freely chosen cadence and leg strength in veteran cyclists. Method: Twenty-two well trained veteran cyclists (age: 47 ±6 years, maximal oxygen consumption (VO2max: 57.9 ±3.7 ml. kg-1. min-1 were randomized into two groups, a low cadence training group and a freely chose cadence training group. Respiratory variables, power output, cadence and leg strength were tested before and after a 12 weeks training intervention period. The low cadence training group performed 12 weeks of moderate (73-82 % of maximal heart rate (HRmax interval training (5 x 6 min with a cadence of 40 revolutions per minute (rpm two times a week, in addition to their usual training. The freely chosen cadence group added 90 minutes of training at freely chosen cadence at moderate intensity. Results: No significant effects of the low cadence training on aerobic capacity, cycling performance, power output, cadence, gross efficiency or leg strength was found. The freely chosen cadence group significantly improved both VO2max (58.9±2.4 vs. 62.2±3.2 ml. kg-1. min-1, VO2 consumption at lactate threshold (49.4 ±3.8 vs. 51.8±3.5 ml. kg-1. min-1 and during the 30 min performance test (52.8±3.0 vs. 54.7±3.5 ml. kg-1. min-1, and power output at lactate threshold (284 ±47 vs. 294 ±48 W and during the 30 min performance test (284±42 vs. 297±50 W. Conclusion: Twelve weeks of low cadence (40 rpm interval training at moderate intensity (73-82 % of HRmax twice a week does not improve aerobic capacity, cycling performance or leg strength in highly trained veteran cyclists. However, adding training at same intensity (% of HRmax and duration (90 minutes weekly at freely chosen cadence seems beneficial for performance and physiological adaptations.

  14. High intensity training improves exercise performance in elite women volleyball players during a competitive season

    DEFF Research Database (Denmark)

    Purkhús, Elisabeth; Krustrup, Peter; Mohr, Magni

    2016-01-01

    separated by 25 s of recovery), and the Yo-Yo Intermittent Recovery level 2 test (Yo-Yo IR2) followed by a-10 min rest period and the Yo-Yo IR1 test. Mean running distance during HIT-training in wk-1 was 152±4 m and increased (P....87±0.97 to 18.44±1.06 s) and RST by 4.3% post-intervention in the HIT-group only. Baseline RST fatigue index (FI) was 7.0±2.9 and 6.2±5.0% in HIT and CON, respectively, but was lowered (PYo-Yo IR2 and Yo-Yo IR1 performance...

  15. Mental fatigue negatively influences manual dexterity and anticipation timing but not repeated high-intensity exercise performance in trained adults.

    Science.gov (United States)

    Duncan, Michael J; Fowler, Nicholas; George, Oliver; Joyce, Samuel; Hankey, Joanne

    2015-01-01

    This study examined the impact of a period of mental fatigue on manual dexterity, anticipation timing and repeated high intensity exercise performance. Using a randomised, repeated measures experimental design, eight physically trained adults (mean age = 24.8 ± 4.1 years) undertook a 40 minute vigilance task to elicit mental fatigue or a control condition followed by four repeated Wingate anaerobic performance tests. Pre, post fatigue/control and post each Wingate test, manual dexterity (Seconds), coincidence anticipation (absolute error) were assessed. A series of two (condition) by six (time) ways repeated measures ANOVAs indicated a significant condition by time interactions for manual dexterity time (p = 0.021) and absolute error (p = 0.028). Manual dexterity and coincidence anticipation were significantly poorer post mental fatigue compared with control. There were no significant differences in mean power between conditions or across trials (all p > 0.05).

  16. EFFECTS OF FREQUENCY OF WRITING AND INTENSITY OF TEACHER EVALUATION UPON HIGH SCHOOL STUDENTS' PERFORMANCE IN WRITTEN COMPOSITION.

    Science.gov (United States)

    ARNOLD, LOIS V.; BURTON, DWIGHT L.

    THE PROBLEM OF THIS RESEARCH WAS TO INVESTIGATE THE EFFECTS OF FREQUENCY OF WRITING AND INTENSITY OF TEACHER EVALUATION UPON PERFORMANCE BY STUDENTS OF VARYING ABILITIES. THE STUDY WAS DESIGNED TO INCLUDE EIGHT 10TH-GRADE CLASSES WITH TWO TEACHERS FOLLOWING FOUR DIFFERENT APPROACHES TO INTENSITY OF TEACHER EVALUATION AND FREQUENCY OF WRITING.…

  17. Combined inhalation of beta2 -agonists improves swim ergometer sprint performance but not high-intensity swim performance

    DEFF Research Database (Denmark)

    Kalsen, Anders; Hostrup, Morten; Bangsbo, Jens

    2014-01-01

    ), in permitted doses within the World Anti-Doping Agency 2013 prohibited list, in elite swimmers with (AHR, n = 13) or without (non-AHR, n = 17) AHR. Maximal voluntary isometric contraction of m. quadriceps (MVC), sprint performance on a swim ergometer and performance in an exhaustive swim test at 110% of VO2max...

  18. Endurance, aerobic high-intensity, and repeated sprint cycling performance is unaffected by normobaric "Live High-Train Low"

    DEFF Research Database (Denmark)

    Bejder, Jacob; Andersen, Andreas Breenfeldt; Buchardt, Rie

    2017-01-01

    The aim was to investigate whether 6 weeks of normobaric "Live High-Train Low" (LHTL) using altitude tents affect highly trained athletes incremental peak power, 26-km time-trial cycling performance, 3-min all-out performance, and 30-s repeated sprint ability. In a double-blinded, placebo...... conducted in a double-blinded, placebo-controlled cross-over design do not affect power output during an incremental test, a ~26-km time-trial test, or 3-min all-out exercise in highly trained triathletes. Furthermore, 30 s of repeated sprint ability was unaltered.......-out exercise, and 8 × 30 s of all-out sprint was evaluated before and after the intervention. Following at least 8 weeks of wash-out, the subjects crossed over and repeated the procedure. Incremental peak power output was similar after both interventions [LHTL: 375 ± 74 vs. 369 ± 70 W (pre-vs-post), placebo...

  19. Effect of immediate and delayed cold water immersion after a high intensity exercise session on subsequent run performance.

    Science.gov (United States)

    Brophy-Williams, Ned; Landers, Grant; Wallman, Karen

    2011-01-01

    The purpose of the study was to determine the effects of cold water immersion (CWI) performed immediately or 3 h after a high intensity interval exercise session (HIIS) on next-day exercise performance. Eight male athletes performed three HIIS at 90%VO2max velocity followed by either a passive recovery (CON), CWI performed immediately post-exercise (CWI(0)) or CWI performed 3 h post-exercise (CWI(3)). Recovery trials were performed in a counter balanced manner. Participants then returned 24 h later and completed a muscle soreness and a totally quality recovery perception (TQRP) questionnaire, which was then followed by the Yoyo Intermittent Recovery Test [level 1] (YRT). Venous blood samples were collected pre-HIIS and pre-YRT to determine C-Reactive Protein (CRP) levels. Significantly more shuttles were performed during the YRT following CWI(0) compared to the CON trial (p=0.017, ES = 0. 8), while differences between the CWI(3) and the CON trials approached significance (p = 0.058, ES = 0.5). Performance on the YRT between the CWI(0) and CWI(3) trials were similar (p = 0.147, ES = 0. 3). Qualitative analyses demonstrated a 98% and 92% likely beneficial effect of CWI(0) and CWI(3) on next day performance, compared to CON, respectively, while CWI(0) resulted in a 79% likely benefit when compared to CWI(3). CRP values were significantly lower pre-YRT, compared to baseline, following CWI(0) (p = 0.0.36) and CWI(3) (p = 0.045), but were similar for CON (p = 0.157). Muscle soreness scores were similar between trials (p = 1.10), while TQRP scores were significantly lower for CON compared to CWI(0) (p = 0.002 ) and CWI(3) (p = 0.024). Immediate CWI resulted in superior next-day YRT performance compared to CON, while delayed (3 h) CWI was also likely to be beneficial. Qualitative analyses suggested that CWI(0) resulted in better performance than CWI(3). These results are important for athletes who do not have immediate access to CWI following exercise. Key pointsPerformance

  20. Efficacy of acute caffeine ingestion for short-term high-intensity exercise performance: a systematic review.

    Science.gov (United States)

    Astorino, Todd A; Roberson, Daniel W

    2010-01-01

    Caffeine is the most widely used drug in the world, commonly ingested in coffee, tea, soda, and energy drinks. Its ability to enhance muscular work has been apparent since the early 1900s. Caffeine typically increases endurance performance; however, efficacy of caffeine ingestion for short-term high-intensity exercise is equivocal, which may be explained by discrepancies in exercise protocols, dosing, and subjects' training status and habitual caffeine intake found across studies. The primary aim of this review is to critically examine studies that have tested caffeine's ability to augment performance during exercise dependent on nonoxidative metabolism such as sprinting, team sports, and resistance training. A review of the literature revealed 29 studies that measured alterations in short-term performance after caffeine ingestion. Each study was critically analyzed using the Physiotherapy Evidence Database (PEDro) scale. The mean PEDro score was 7.76 +/- 0.87. Eleven of 17 studies revealed significant improvements in team sports exercise and power-based sports with caffeine ingestion, yet these effects were more common in elite athletes who do not regularly ingest caffeine. Six of 11 studies revealed significant benefits of caffeine for resistance training. Some studies show decreased performance with caffeine ingestion when repeated bouts are completed. The exact mechanism explaining the ergogenic effect of caffeine for short-term exercise is unknown.

  1. Elite female soccer players perform more high-intensity running when playing in international games compared with domestic league games

    DEFF Research Database (Denmark)

    Andersson, Helena Å.; Randers, Morten Bredsgaard; Heiner-Møller, Anja

    2010-01-01

    The purpose of this study was to compare movement pattern, fatigue development, and heart rate (HR) for top-class elite female players when playing international (INT) vs. domestic league games (DOM). Video-based time-motion analyses and HR recordings were performed on 17 players during INT and DOM....... The distances covered in high-intensity running (HIR) and sprinting were longer (p types...... no differences were observed between the game types for defenders. No difference in the HR response was found between INT and DOM. In conclusion, more HIR and sprinting occur in international compared with domestic games, which may affect the fatigue development for players in physically demanding roles. Thus...

  2. High-Intensity Intermittent Training Positively Affects Aerobic and Anaerobic Performance in Judo Athletes Independently of Exercise Mode

    Science.gov (United States)

    Franchini, Emerson; Julio, Ursula F.; Panissa, Valéria L. G.; Lira, Fábio S.; Gerosa-Neto, José; Branco, Braulio H. M.

    2016-01-01

    Purpose: The present study investigated the effects of high-intensity intermittent training (HIIT) on lower- and upper-body graded exercise and high-intensity intermittent exercise (HIIE, four Wingate bouts) performance, and on physiological and muscle damage markers responses in judo athletes. Methods: Thirty-five subjects were randomly allocated to a control group (n = 8) or to one of the following HIIT groups (n = 9 for each) and tested pre- and post-four weeks (2 training d·wk−1): (1) lower-body cycle-ergometer; (2) upper-body cycle-ergometer; (3) uchi-komi (judo technique entrance). All HIIT were constituted by two blocks of 10 sets of 20 s of all out effort interspersed by 10 s set intervals and 5-min between blocks. Results: For the upper-body group there was an increase in maximal aerobic power in graded upper-body exercise test (12.3%). The lower-body group increased power at onset blood lactate in graded upper-body exercise test (22.1%). The uchi-komi group increased peak power in upper- (16.7%) and lower-body (8.5%), while the lower-body group increased lower-body mean power (14.2%) during the HIIE. There was a decrease in the delta blood lactate for the uchi-komi training group and in the third and fourth bouts for the upper-body training group. Training induced testosterone-cortisol ratio increased in the lower-body HIIE for the lower-body (14.9%) and uchi-komi (61.4%) training groups. Conclusion: Thus, short-duration low-volume HIIT added to regular judo training was able to increase upper-body aerobic power, lower- and upper-body HIIE performance. PMID:27445856

  3. EFFECT OF IMMEDIATE AND DELAYED COLD WATER IMMERSION AFTER A HIGH INTENSITY EXERCISE SESSION ON SUBSEQUENT RUN PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Ned Brophy-Williams

    2011-12-01

    Full Text Available The purpose of the study was to determine the effects of cold water immersion (CWI performed immediately or 3 h after a high intensity interval exercise session (HIIS on next-day exercise performance. Eight male athletes performed three HIIS at 90%VO2max velocity followed by either a passive recovery (CON, CWI performed immediately post-exercise (CWI(0 or CWI performed 3 h post-exercise (CWI(3. Recovery trials were performed in a counter balanced manner. Participants then returned 24 h later and completed a muscle soreness and a totally quality recovery perception (TQRP questionnaire, which was then followed by the Yoyo Intermittent Recovery Test [level 1] (YRT. Venous blood samples were collected pre-HIIS and pre-YRT to determine C-Reactive Protein (CRP levels. Significantly more shuttles were performed during the YRT following CWI(0 compared to the CON trial (p=0.017, ES = 0. 8, while differences between the CWI(3 and the CON trials approached significance (p = 0.058, ES = 0.5. Performance on the YRT between the CWI(0 and CWI(3 trials were similar (p = 0.147, ES = 0. 3. Qualitative analyses demonstrated a 98% and 92% likely beneficial effect of CWI(0 and CWI(3 on next day performance, compared to CON, respectively, while CWI(0 resulted in a 79% likely benefit when compared to CWI(3. CRP values were significantly lower pre-YRT, compared to baseline, following CWI(0 (p = 0.0.36 and CWI(3 (p = 0.045, but were similar for CON (p = 0.157. Muscle soreness scores were similar between trials (p = 1.10, while TQRP scores were significantly lower for CON compared to CWI(0 (p = 0.002 and CWI(3 (p = 0.024. Immediate CWI resulted in superior next-day YRT performance compared to CON, while delayed (3 h CWI was also likely to be beneficial. Qualitative analyses suggested that CWI(0 resulted in better performance than CWI(3. These results are important for athletes who do not have immediate access to CWI following exercise

  4. Effects of a seven day overload-period of high-intensity training on performance and physiology of competitive cyclists.

    Directory of Open Access Journals (Sweden)

    Bradley Clark

    Full Text Available Competitive endurance athletes commonly undertake periods of overload training in the weeks prior to major competitions. This investigation examined the effects of two seven-day high-intensity overload training regimes (HIT on performance and physiological characteristics of competitive cyclists.The study was a matched groups, controlled trial.Twenty-eight male cyclists (mean ± SD, Age: 33±10 years, Mass 74±7 kg, VO2 peak 4.7±0.5 L·min-1 were assigned to a control group or one of two training groups for seven consecutive days of HIT. Before and after training cyclists completed an ergometer based incremental exercise test and a 20-km time-trial. The HIT sessions were ∼120 minutes in duration and consisted of matched volumes of 5, 10 and 20 second (short or 15, 30 and 45 second (long maximal intensity efforts.Both the short and long HIT regimes led to significant (p0.05 increases (mean ± SD in VO2 peak (2.3%±4.7% vs 3.5%±6.2%, lactate threshold power (3.6%±3.5% vs 2.9%±5.3% and gross efficiency (3.2%±2.4% vs 5.1%±3.9% with only small differences between HIT regimes.Seven days of overload HIT induces substantial enhancements in time-trial performance despite non-significant increases in physiological measures with competitive cyclists.

  5. Metabolism and performance during extended high-intensity intermittent exercise after consumption of low- and high-glycaemic index pre-exercise meals.

    Science.gov (United States)

    Bennett, Christine B; Chilibeck, Philip D; Barss, Trevor; Vatanparast, Hassanali; Vandenberg, Albert; Zello, Gordon A

    2012-08-01

    The metabolic and performance benefits of prior consumption of low-glycaemic index (GI) meals v. high-GI meals were determined in extended high-intensity intermittent exercise. Participants (ten males and four females, aged 25·8 (sd 7·3) years) completed two testing days (each consisting of back-to-back 90-min intermittent high-intensity treadmill running protocols separated by 3 h) spaced by at least 7 d. Using a randomised counterbalanced cross-over design, low-GI, lentil-based meals (GI about 42) or high-GI, potato-based meals (GI about 78) matched for energy value were consumed 2 h before, and within 1 h after, the first exercise session. Performance was measured by the distance covered during five 1-min sprints (separated by 2·5 min walking) at the end of each exercise session. Peak postprandial blood glucose was higher by 30·8 % in the high-GI trial compared with the low-GI trial, as was insulin (P = 0·039 and P = 0·003, respectively). Carbohydrate oxidation was lower by 5·5 % during the low-GI trials compared with the high-GI trials at the start of the first exercise session (P exercise session during the high-GI trial compared with the low-GI trial. Sprint distance was not significantly different between conditions. A low-GI meal improved the metabolic profile before and during extended high-intensity intermittent exercise, but did not affect performance. Improvements in metabolic responses when consuming low-GI meals before exercise may be beneficial to the long-term health of athletes.

  6. High-intensity intermittent exercise training with chlorella intake accelerates exercise performance and muscle glycolytic and oxidative capacity in rats.

    Science.gov (United States)

    Horii, Naoki; Hasegawa, Natsuki; Fujie, Shumpei; Uchida, Masataka; Miyamoto-Mikami, Eri; Hashimoto, Takeshi; Tabata, Izumi; Iemitsu, Motoyuki

    2017-04-01

    The purpose of this study was to investigate the effect of chronic chlorella intake alone or in combination with high-intensity intermittent exercise (HIIE) training on exercise performance and muscle glycolytic and oxidative metabolism in rats. Forty male Sprague-Dawley rats were randomly assigned to the four groups: sedentary control, chlorella intake (0.5% chlorella powder in normal feed), HIIE training, and combination of HIIE training and chlorella intake for 6 wk (n = 10 each group). HIIE training comprised 14 repeats of a 20-s swimming session with a 10-s pause between sessions, while bearing a weight equivalent to 16% of body weight, 4 days/week. Exercise performance was tested after the interventions by measuring the maximal number of HIIE sessions that could be completed. Chlorella intake and HIIE training significantly increased the maximal number of HIIE sessions and enhanced the expression of monocarboxylate transporter (MCT)1, MCT4, and peroxisome proliferator-activated receptor γ coactivator-1α concomitantly with the activities of lactate dehydrogenase (LDH), phosphofructokinase, citrate synthase (CS), and cytochrome-c oxidase (COX) in the red region of the gastrocnemius muscle. Furthermore, the combination further augmented the increased exercise performance and the enhanced expressions and activities. By contrast, in the white region of the muscle, MCT1 expression and LDH, CS, and COX activities did not change. These results showed that compared with only chlorella intake and only HIIE training, chlorella intake combined with HIIE training has a more pronounced effect on exercise performance and muscle glycolytic and oxidative metabolism, in particular, lactate metabolism. Copyright © 2017 the American Physiological Society.

  7. Testing of Performance of Optical Fibers Under Irradiation in Intense Radiation Fields, When Subjected to Very High Temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Blue, Thomas [The Ohio State Univ., Columbus, OH (United States); Windl, Wolfgang [The Ohio State Univ., Columbus, OH (United States); Dickerson, Bryan [Luna Innovations, Inc. (United States)

    2013-01-03

    The primary objective of this project is to measure and model the performance of optical fibers in intense radiation fields when subjected to very high temperatures. This research will pave the way for fiber optic and optically based sensors under conditions expected in future high-temperature gas-cooled reactors. Sensor life and signal-to-noise ratios are susceptible to attenuation of the light signal due to scattering and absorbance in the fibers. This project will provide an experimental and theoretical study of the darkening of optical fibers in high-radiation and high-temperature environments. Although optical fibers have been studied for moderate radiation fluence and flux levels, the results of irradiation at very high temperatures have not been published for extended in-core exposures. Several previous multi-scale modeling efforts have studied irradiation effects on the mechanical properties of materials. However, model-based prediction of irradiation-induced changes in silica's optical transport properties has only recently started to receive attention due to possible applications as optical transmission components in fusion reactors. Nearly all damage-modeling studies have been performed in the molecular-dynamics domain, limited to very short times and small systems. Extended-time modeling, however, is crucial to predicting the long-term effects of irradiation at high temperatures, since the experimental testing may not encompass the displacement rate that the fibers will encounter if they are deployed in the VHTR. The project team will pursue such extended-time modeling, including the effects of the ambient and recrystallization. The process will be based on kinetic MC modeling using the concept of amorphous material consisting of building blocks of defect-pairs or clusters, which has been successfully applied to kinetic modeling in amorphized and recrystallized silicon. Using this procedure, the team will model compensation for rate effects, and

  8. High-intensity interval training with vibration as rest intervals attenuates fiber atrophy and prevents decreases in anaerobic performance.

    Directory of Open Access Journals (Sweden)

    Sandro Manuel Mueller

    Full Text Available Aerobic high-intensity interval training (HIT improves cardiovascular capacity but may reduce the finite work capacity above critical power (W' and lead to atrophy of myosin heavy chain (MyHC-2 fibers. Since whole-body vibration may enhance indices of anaerobic performance, we examined whether side-alternating whole-body vibration as a replacement for the active rest intervals during a 4 x 4 min HIT prevents decreases in anaerobic performance and capacity without compromising gains in aerobic function. Thirty-three young recreationally active men were randomly assigned to conduct either conventional 4 x 4 min HIT, HIT with 3 min of WBV at 18 Hz (HIT+VIB18 or 30 Hz (HIT+VIB30 in lieu of conventional rest intervals, or WBV at 30 Hz (VIB30. Pre and post training, critical power (CP, W', cellular muscle characteristics, as well as cardiovascular and neuromuscular variables were determined. W' (-14.3%, P = 0.013, maximal voluntary torque (-8.6%, P = 0.001, rate of force development (-10.5%, P = 0.018, maximal jumping power (-6.3%, P = 0.007 and cross-sectional areas of MyHC-2A fibers (-6.4%, P = 0.044 were reduced only after conventional HIT. CP, V̇O2peak, peak cardiac output, and overall capillary-to-fiber ratio were increased after HIT, HIT+VIB18, and HIT+VIB30 without differences between groups. HIT-specific reductions in anaerobic performance and capacity were prevented by replacing active rest intervals with side-alternating whole-body vibration, notably without compromising aerobic adaptations. Therefore, competitive cyclists (and potentially other endurance-oriented athletes may benefit from replacing the active rest intervals during aerobic HIT with side-alternating whole-body vibration.ClinicalTrials.gov Identifier: NCT01875146.

  9. A Secure Web Application Providing Public Access to High-Performance Data Intensive Scientific Resources - ScalaBLAST Web Application

    Energy Technology Data Exchange (ETDEWEB)

    Curtis, Darren S.; Peterson, Elena S.; Oehmen, Chris S.

    2008-05-04

    This work presents the ScalaBLAST Web Application (SWA), a web based application implemented using the PHP script language, MySQL DBMS, and Apache web server under a GNU/Linux platform. SWA is an application built as part of the Data Intensive Computer for Complex Biological Systems (DICCBS) project at the Pacific Northwest National Laboratory (PNNL). SWA delivers accelerated throughput of bioinformatics analysis via high-performance computing through a convenient, easy-to-use web interface. This approach greatly enhances emerging fields of study in biology such as ontology-based homology, and multiple whole genome comparisons which, in the absence of a tool like SWA, require a heroic effort to overcome the computational bottleneck associated with genome analysis. The current version of SWA includes a user account management system, a web based user interface, and a backend process that generates the files necessary for the Internet scientific community to submit a ScalaBLAST parallel processing job on a dedicated cluster.

  10. High-intensity training in football.

    Science.gov (United States)

    Iaia, F Marcello; Rampinini, Ermanno; Bangsbo, Jens

    2009-09-01

    This article reviews the major physiological and performance effects of aerobic high-intensity and speed-endurance training in football, and provides insight on implementation of individual game-related physical training. Analysis and physiological measurements have revealed that modern football is highly energetically demanding, and the ability to perform repeated high-intensity work is of importance for the players. Furthermore, the most successful teams perform more high-intensity activities during a game when in possession of the ball. Hence, footballers need a high fitness level to cope with the physical demands of the game. Studies on football players have shown that 8 to 12 wk of aerobic high-intensity running training (> 85% HR(max)) leads to VO2(max) enhancement (5% to 11%), increased running economy (3% to 7%), and lower blood lactate accumulation during submaximal exercise, as well as improvements in the yo-yo intermittent recovery (YYIR) test performance (13%). Similar adaptations are observed when performing aerobic high-intensity training with small-sided games. Speed-endurance training has a positive effect on football-specific endurance, as shown by the marked improvements in the YYIR test (22% to 28%) and the ability to perform repeated sprints (approximately 2%). In conclusion, both aerobic and speed-endurance training can be used during the season to improve high-intensity intermittent exercise performance. The type and amount of training should be game related and specific to the technical, tactical, and physical demands imposed on each player.

  11. High-Intensity Cycling Training: The Effect of Work-to-Rest Intervals on Running Performance Measures.

    Science.gov (United States)

    Kavaliauskas, Mykolas; Aspe, Rodrigo R; Babraj, John

    2015-08-01

    The work-to-rest ratio during cycling-based high-intensity interval training (HIT) could be important in regulating physiological and performance adaptations. We sought to determine the effectiveness of cycling-based HIT with different work-to-rest ratios for long-distance running. Thirty-two long-distance runners (age: 39 ± 8 years; sex: 14 men, 18 women; average weekly running training volume: 25 miles) underwent baseline testing (3-km time-trial, V[Combining Dot Above]O2peak and time to exhaustion, and Wingate test) before a 2-week matched-work cycling HIT of 6 × 10-second sprints with different rest periods (30 seconds [R30], 80 seconds [R80], 120 seconds [R120], or control). Three-kilometer time trial was significantly improved in the R30 group only (3.1 ± 4.0%, p = 0.04), whereas time to exhaustion was significantly increased in the 2 groups with a lower work-to-rest ratio (R30 group 6.4 ± 6.3%, p = 0.003 vs. R80 group 4.4 ± 2.7%, p = 0.03 vs. R120 group 1.9 ± 5.0%, p = 0.2). However, improvements in average power production were significantly greater with a higher work-to-rest ratio (R30 group 0.3 ± 4.1%, p = 0.8 vs. R80 group 4.6 ± 4.2%, p = 0.03 vs. R120 group 5.3 ± 5.9%, p = 0.02), whereas peak power significantly increased only in the R80 group (8.5 ± 8.2%, p = 0.04) but not in the R30 group (4.3 ± 6.1%, p = 0.3) or in the R120 group (7.1 ± 7.9%, p = 0.09). Therefore, cycling-based HIT is an effective way to improve running performance, and the type and magnitude of adaptation is dependent on the work-to-rest ratio.

  12. High Intensity Interval Training: New Insights

    Institute of Scientific and Technical Information of China (English)

    Martin J.Gibala

    2008-01-01

    @@ KEY POINTS ·High-intensity interval training(HIT)is characterized by repeated sessions of relatively brief,intermittent exercise.often performed with an“a11 out”effort or at an intensity close to that which elicits peak oxygen uptake(i.e.,≥90%of VO2 peak).

  13. Rapid high-performance sample digestion of base metal ores using high-intensity infrared radiation with determination by nitrogen-based microwave plasma optical spectrometry

    Directory of Open Access Journals (Sweden)

    Yong Wang

    2016-03-01

    Full Text Available Infrared sample digestion technology has been rapidly developed in recent years and its application and digestion performance on a variety of ores of base metals was assessed in this study, using a 6-channel infrared digester. Digestion times of 10 min or less were achieved for all base metal ores investigated, including oxides, sulfides, and silicates of Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Ti, W, and Zn. Performance criteria for all samples were excellent, reflected in z values of less than 2 in all cases. Various acid digestion methods were developed for the selected ore samples under high intensity infrared radiation and delivered virtually complete recoveries of all of the elements of interest. Chromite, the notoriously refractory chromium ore was digested within 10 min and gave 100% recovery of chromium. These digestions were accomplished without resorting to perchloric acid and, for most sample types, without hydrofluoric acid, significantly improving the workplace safety for analysts. Between-channel variation of the analyte recoveries from the 6-channel unit were generally below 2%, suggesting that the digestion methods developed with this platform provide reproducible results to meet various sample preparation demands. The high speed and analyte recovery of these digestions makes this methodology especially attractive for prospectors and developers who demand rapid and reliable results from exploration samples.

  14. High intensity protons in RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Montag, C.; Ahrens, L.; Blaskiewicz, M.; Brennan, J. M.; Drees, K. A.; Fischer, W.; Huang, H.; Minty, M.; Robert-Demolaize, G.; Thieberger, P.; Yip, K.

    2012-01-05

    During the 2012 summer shutdown a pair of electron lenses will be installed in RHIC, allowing the beam-beam parameter to be increased by roughly 50 percent. To realize the corresponding luminosity increase bunch intensities have to be increased by 50 percent, to 2.5 {center_dot} 10{sup 11} protons per bunch. We list the various RHIC subsystems that are most affected by this increase, and propose beam studies to ensure their readiness. The proton luminosity in RHIC is presently limited by the beam-beam effect. To overcome this limitation, electron lenses will be installed in IR10. With the help of these devices, the headon beam-beam kick experienced during proton-proton collisions will be partially compensated, allowing for a larger beam-beam tuneshift at these collision points, and therefore increasing the luminosity. This will be accomplished by increasing the proton bunch intensity from the presently achieved 1.65 {center_dot} 10{sup 11} protons per bunch in 109 bunches per beam to 2.5 {center_dot} 10{sup 11}, thus roughly doubling the luminosity. In a further upgrade we aim for bunch intensities up to 3 {center_dot} 10{sup 11} protons per bunch. With RHIC originally being designed for a bunch intensity of 1 {center_dot} 10{sup 11} protons per bunch in 56 bunches, this six-fold increase in the total beam intensity by far exceeds the design parameters of the machine, and therefore potentially of its subsystems. In this note, we present a list of major subsystems that are of potential concern regarding this intensity upgrade, show their demonstrated performance at present intensities, and propose measures and beam experiments to study their readiness for the projected future intensities.

  15. Pre-exercise low-level laser therapy improves performance and levels of oxidative stress markers in mdx mice subjected to muscle fatigue by high-intensity exercise.

    Science.gov (United States)

    Silva, Andreia Aparecida de Oliveira; Leal-Junior, Ernesto Cesar Pinto; D'Avila, Katia de Angelis Lobo; Serra, Andrey Jorge; Albertini, Regiane; França, Cristiane Miranda; Nishida, Joen Akemi; de Carvalho, Paulo de Tarso Camillo

    2015-08-01

    This study was designed to determine if the levels of oxidative stress markers are influenced by low-level laser therapy (LLLT) in mdx mice subjected to high-intensity exercise training on an electric treadmill. We used 21 C57BL/10ScSn-Dmdmdx/J mice and 7 C57BL/10ScSn mice, all aged 4 weeks. The mice were divided into four groups: a positive control group of normal, wild-type mice (WT); a negative control group of untreated mdx mice; a group of mdx mice that underwent forced high-intensity exercise on a treadmill (mdx fatigue); and another group of mdx mice with the same characteristics that were treated with LLLT at a single point on the gastrocnemius muscle of the hind paw and underwent forced high-intensity exercise on a treadmill. The mdx mice treated with LLLT showed significantly lower levels of creatine kinase (CK) and oxidative stress than mdx mice that underwent forced high-intensity exercise on a treadmill. The activities of the antioxidant enzyme superoxide dismutase (SOD) were higher in control mdx mice than in WT mice. LLLT also significantly reduced the level of this marker. LLLT had a beneficial effect also on the skeletal muscle performance of mdx mice. However, the single application of LLLT and the dose parameters used in this study were not able to change the morphology of a dystrophic muscle.

  16. Effect of Wheelchair Running on Recovery of Blood Lactate and Physical Performance after High-Intensity Intermittent Exercise – An Experimental Trial

    Directory of Open Access Journals (Sweden)

    Karthikeyan G

    2012-04-01

    Full Text Available Background and Purpose: Repetitive sprint sport players perform high intensity exercise only for a small percentage of a total game and such periods are often instrumental in determining the eventual outcome. Recovery is a key factor for performance, and constant lack of recovery or insufficient recovery turns into overtraining which is detrimental in achieving peak performance. The purpose was to find out the effect of wheelchair running on the physical performance recovery after high-intensity intermittent exercise. Method: Ten sportsmen having the age range from 20 to 29, VO2max Ranges from 60.51 to 64.29 were randomly divided into experimental and control groups. After filling pre-participation questionnaire and 30-min of supine rest, Blood lactate and the field tests for the measurement of static balance, power, speed and agility were applied. The subjects were made to run in the treadmill and to increase the intensity to reach the Target Heart Rate (THR. After 1-min the subjects were given rest for 15-s and after that they started exercise again and thus the subjects completed several bouts of such exercises until exhaustion followed by either Passive rest or wheelchair running for the duration of 10 minutes. Parameters were measures after completed the exercise bout and after the recovery. Results: After the recovery in experimental group significant improvement found only in blood lactate (p<0.01 and no significant changes found in other parameters while in control group no significant changes found in all parameters. There was no significant difference found in all the parameters including blood lactate between the groups. Conclusion: Both wheelchair running and passive recovery are same in the efficiency of blood lactate removal and restoration of physical performance following intense intermittent exercise.

  17. The impact of intensive high performance training on adult height of female artistic gymnasts: a retrospective study

    Directory of Open Access Journals (Sweden)

    Raul Alves FERREIRA-FILHO

    2016-03-01

    Full Text Available Abstract The purpose of this study was to identify the potential impact of the high performance training on the anthropometric and maturational characteristics of female artistic gymnasts and to compare the adult target height with international standards of growth. A sample consisted of 23 elite Brazilian female former gymnasts was evaluated. From a historic retrospective, about 29.56 yrs. ago (average of all they devoted themselves to the training for 9.3 (2.6 years, with a weekly 24.26 (4.2 training hours, and had been retired from competition around at 13.61 (5.12 years old. From the anthropometric data of the gymnasts (while still competing, their parents and their older sister (1 and younger sister (2, the target height was calculated by Tanner method {[(father’s height -13 cm + mother’s height] ÷ 2}. Additionally, training history, age of menarche occurrence, and growth classifying in accordance with the international standards was recorded, aimed at comparisons. The average stature shown normal adult stature (NCHS, and some cases surpassed the standard 75th, 90th and 95th percentile. They are higher than their mother (p = 0.039, but not their sister 1 (0.952 or sister 2 (p = 0.998, but the age of menarche was significantly later only than their sisters 1 (p = 0.008 and 2 (p = 0.017. According to the Brazilian percentiles reference (IBGE, the final height of the former gymnasts was always higher of the standard, slightly smaller than their sisters 2 (5th and 10th, but was taller than their mothers and sisters 1. In conclusion, there is no evidence of artistic gymnastics high performance training having adverse effects on the final adult height.

  18. The occurrence of core muscle fatigue during high-intensity running exercise and its limitation to performance: the role of respiratory work.

    Science.gov (United States)

    Tong, Tomas K; Wu, Shing; Nie, Jinlei; Baker, Julien S; Lin, Hua

    2014-05-01

    This study investigated the occurrence of core muscle fatigue during high-intensity running exercise and its limitation to exercise performance. A secondary aim was to investigate whether respiratory muscle work performed during intense running periods, would contribute to core muscle fatigue. Nine male recreational runners were recruited for two reasons; (1) to perform a continuous treadmill run at 85% VO2max with and without core muscle fatigue in the CR_F and CR trials, respectively; and (2) to mimic the treadmill run-induced respiratory response recorded in the CR trial while subjects were free of whole-body exercise (Mimic trial). The changes in global core muscle function with fatigue in this study were evaluated by performing a sport-specific endurance plank test (SEPT), and the associated influence on running performance was examined by comparing the time to exhaustion during the treadmill run between the CR and CR_F trials. Subsequent to the treadmill run in the CR trial, SEPT (255.7 ± 85.3 vs 177.3 ± 80.6 s) was reduced from baseline in all runners. The reduction correlated (r = 0.67) with the concomitant decline in inspiratory muscle function revealed by maximal inspiratory mouth pressure (PImax: 151.3 ± 18.2 vs 133.3 ± 17.2 cmH2O, p core muscle workout in the CR_F trial, the running capacity was impaired significantly (10.7 ± 4.5 vs 6.5 ± 2.0 min, p core muscle fatigue in runners. The core muscle fatigue, which may be partly attributed to the corresponding respiratory work, may limit their running endurance. Inspiratory muscle function appears to be essential for core stabilization during the intense running. Key pointsA high-intensity maximum run may induce core muscle fatigue in runners. The core muscle fatigue, which may be partly attributed to the corresponding respiratory work, may limit their running endurance.In support of previous notion, inspiratory muscles may share the work of core stabilization during intense exercise, while

  19. LHC Report: reaching high intensity

    CERN Multimedia

    Jan Uythoven

    2015-01-01

    After both beams having been ramped to their full energy of 6.5 TeV, the last two weeks saw the beam commissioning process advancing on many fronts. An important milestone was achieved when operators succeeded in circulating a nominal-intensity bunch. During the operation, some sudden beam losses resulted in beam dumps at top energy, a problem that needed to be understood and resolved.   In 2015 the LHC will be circulating around 2800 bunches in each beam and each bunch will contain just over 1 x 1011 protons. Until a few days ago commissioning was taking place with single bunches of 5 x 109 protons. The first nominal bunch with an intensity of 1 x 1011 protons was injected on Tuesday, 21 April. In order to circulate such a high-intensity bunch safely, the whole protection system must be working correctly: collimators, which protect the aperture, are set at preliminary values known as coarse settings; all kicker magnets for injecting and extracting the beams are commissioned with beam an...

  20. Effects of in-season short-term aerobic and high-intensity interval training program on repeated sprint ability and jump performance in handball players.

    Science.gov (United States)

    Hermassi, Souhail; Ingebrigtsen, Jørgen; Schwesig, René; Fieseler, Georg; Delank, Karl S; Chamari, Karim; Shephard, Roy J; Chelly, Mohamed S

    2016-11-16

    This study examined the effects of a 7-week in-season aerobic and high-intensity interval-training program on performance tests linked to successful handball play (e.g., repeated sprint and jumping ability). Thirty participants (age 17.0 ± 1.2 years, body mass 81.1 ± 3.4 kg, height 1.82± 0.07 m) performed a Yo-Yo Intermittent Recovery Test level 1 (Yo-Yo IR1), a squat (SJ) and a countermovement jump test (CMJ), as well as a repeated sprint ability test (RSA). From this, maximal aerobic speed (MAS, reached at the end of the Yo-Yo IR1), jumping ability, best time in a single sprint trial (RSAbest), total time (RSATT) and the performance decrement (RSAdec) during all sprints were calculated. Later, subjects were randomly assigned to a control group (CG; n=15) performing their normal training schedule (5 weekly sessions of ~90 min of handball training) or an experimental group (EG; n=15). The EG performed two 30 min sessions per week of high-intensity aerobic exercises at 100-130% of MAS in addition to their normal training schedule. Demonstrated a significant improvement in MAS (d=4.1), RSAbest (d=1.9), RSATT (d=1.5) and RSAdec (d=2.3) after the training period. Also, significant interaction effects (time x group) were found for all parameters as the EG significantly improved performances in all tests after training. The greatest interaction effects were observed in MAS (2=0.811) and CMJ (2=0.759). No relevant changes in test performances were found in the CG (mean d=-0.02). These results indicate that individually speed controlled aerobic and interval training is effective for improving specific handball performance.

  1. Supplementation with a Polyphenol-Rich Extract, PerfLoad®, Improves Physical Performance during High-Intensity Exercise: A Randomized, Double Blind, Crossover Trial

    Directory of Open Access Journals (Sweden)

    Julien Cases

    2017-04-01

    Full Text Available Workout capacity is energy-production driven. To produce peak metabolic power outputs, the organism predominantly relies more on anaerobic metabolism, but this undoubtedly has a negative and limiting impact on muscle function and performance. The aim of the study was to evaluate if an innovative polyphenol-based food supplement, PerfLoad®, was able to improve metabolic homeostasis and physical performance during high-intensity exercises under anaerobic conditions. The effect of a supplementation has been investigated on fifteen recreationally-active male athletes during a randomized, double-blind and crossover clinical investigation. The Wingate test, an inducer of an unbalanced metabolism associated to oxidative stress, was used to assess maximum anaerobic power during a high-intensity exercise on a cycle ergometer. Supplementation with PerfLoad® correlated with a significant increase in total power output (5%, maximal peak power output (3.7%, and average power developed (5%, without inducing more fatigue or greater heart rate. Instead, oxidative homeostasis was stabilized in supplemented subjects. Such results demonstrated that PerfLoad® is a natural and efficient solution capable of, similarly to training benefits, helping athletes to improve their physical performance, while balancing their metabolism and reducing exercise-induced oxidative stress.

  2. The ergogenic effect of beta-alanine combined with sodium bicarbonate on high-intensity swimming performance.

    Science.gov (United States)

    Painelli, Vitor de Salles; Roschel, Hamilton; Jesus, Flávia de; Sale, Craig; Harris, Roger Charles; Solis, Marina Yázigi; Benatti, Fabiana Braga; Gualano, Bruno; Lancha, Antonio Herbert; Artioli, Guilherme Giannini

    2013-05-01

    We investigated the effect of beta-alanine (BA) alone (study A) and in combination with sodium bicarbonate (SB) (study B) on 100- and 200-m swimming performance. In study A, 16 swimmers were assigned to receive either BA (3.2 g·day(-1) for 1 week and 6.4 g·day(-1) for 4 weeks) or placebo (PL; dextrose). At baseline and after 5 weeks of supplementation, 100- and 200-m races were completed. In study B, 14 were assigned to receive either BA (3.2 g·day(-1) for 1 week and 6.4 g·day(-1) for 3 weeks) or PL. Time trials were performed once before and twice after supplementation (with PL and SB), in a crossover fashion, providing 4 conditions: PL-PL, PL-SB, BA-PL, and BA-SB. In study A, BA supplementation improved 100- and 200-m time-trial performance by 2.1% (p = 0.029) and 2.0% (p = 0.0008), respectively. In study B, 200-m time-trial performance improved in all conditions, compared with presupplementation, except the PL-PL condition (PL-SB, +2.3%; BA-PL, +1.5%; BA-SB, +2.13% (p supplementation. The probability of BA having a positive effect was 65.2%; when SB was added to BA, the probability was 71.8%. BA and SB supplementation improved 100- and 200-m swimming performance. The coingestion of BA and SB induced a further nonsignificant improvement in performance.

  3. High-performance sports medicine

    National Research Council Canada - National Science Library

    Speed, Cathy

    2013-01-01

    High performance sports medicine involves the medical care of athletes, who are extraordinary individuals and who are exposed to intensive physical and psychological stresses during training and competition...

  4. High-intensity interval training improves VO(2peak), maximal lactate accumulation, time trial and competition performance in 9-11-year-old swimmers.

    Science.gov (United States)

    Sperlich, Billy; Zinner, Christoph; Heilemann, Ilka; Kjendlie, Per-Ludvik; Holmberg, Hans-Christer; Mester, Joachim

    2010-11-01

    Training volume in swimming is usually very high when compared to the relatively short competition time. High-intensity interval training (HIIT) has been demonstrated to improve performance in a relatively short training period. The main purpose of the present study was to examine the effects of a 5-week HIIT versus high-volume training (HVT) in 9-11-year-old swimmers on competition performance, 100 and 2,000 m time (T(100 m) and T(2,000 m)), VO(2peak) and rate of maximal lactate accumulation (Lac(max)). In a 5-week crossover study, 26 competitive swimmers with a mean (SD) age of 11.5 ± 1.4 years performed a training period of HIIT and HVT. Competition (P effect size = 0.48) and T(2,000 m) (P = 0.04; effect size = 0.21) performance increased following HIIT. No changes were found in T(100 m) (P = 0.20). Lac(max) increased following HIIT (P effect size = 0.43) and decreased after HVT (P effect size = 0.51). VO(2peak) increased following both interventions (P effect sizes = 0.46-0.57). The increases in competition performance, T(2,000 m), Lac(max) and VO(2peak) following HIIT were achieved in significantly less training time (~2 h/week).

  5. Performance and burnout in intensive care units

    NARCIS (Netherlands)

    Keijsers, GJ; Schaufeli, WB; LeBlanc, P; Zwerts, C; Miranda, DR

    1995-01-01

    The relationship between three different performance measures and burnout was explored in 20 Dutch Intensive Care Units (ICUs). Burnout (i.e. emotional exhaustion and depersonalization) proved to be significantly related to nurses' perceptions of performance as well as to objectively assessed unit p

  6. Performance and burnout in intensive care units

    NARCIS (Netherlands)

    Keijsers, GJ; Schaufeli, WB; LeBlanc, P; Zwerts, C; Miranda, DR

    1995-01-01

    The relationship between three different performance measures and burnout was explored in 20 Dutch Intensive Care Units (ICUs). Burnout (i.e. emotional exhaustion and depersonalization) proved to be significantly related to nurses' perceptions of performance as well as to objectively assessed unit

  7. Performance analysis of communication links based on VCSEL and silicon photonics technology for high-capacity data-intensive scenario.

    Science.gov (United States)

    Boletti, A; Boffi, P; Martelli, P; Ferrario, M; Martinelli, M

    2015-01-26

    To face the increased demand for bandwidth, cost-effectiveness and simplicity of future Ethernet data communications, a comparison between two different solutions based on directly-modulated VCSEL sources and Silicon Photonics technologies is carried out. Also by exploiting 4-PAM modulation, the transmission of 50-Gb/s and beyond capacity per channel is analyzed by means of BER performance. Applications for optical backplane, very short reach and in case of client-optics networks and intra and inter massive data centers communications (up to 10 km) are taken into account. A comparative analysis based on the power consumption is also proposed.

  8. Improved VO2max and time trial performance with more high aerobic intensity interval training and reduced training volume: a case study on an elite national cyclist.

    Science.gov (United States)

    Støren, Øyvind; Bratland-Sanda, Solfrid; Haave, Marius; Helgerud, Jan

    2012-10-01

    The present study investigated to what extent more high aerobic intensity interval training (HAIT) and reduced training volume would influence maximal oxygen uptake (VO2max) and time trial (TT) performance in an elite national cyclist in the preseason period. The cyclist was tested for VO2max, cycling economy (C(c)), and TT performance on an ergometer cycle during 1 year. Training was continuously logged using heart rate monitor during the entire period. Total monthly training volume was reduced in the 2011 preseason compared with the 2010 preseason, and 2 HAIT blocks (14 sessions in 9 days and 15 sessions in 10 days) were performed as running. Between the HAIT blocks, 3 HAIT sessions per week were performed as cycling. From November 2010 to February 2011, the cyclist reduced total average monthly training volume by 18% and cycling training volume by 60%. The amount of training at 90-95% HRpeak increased by 41%. VO2max increased by 10.3% on ergometer cycle. TT performance improved by 14.9%. C(c) did not change. In conclusion, preseason reduced total training volume but increased amount of HAIT improved VO2max and TT performance without any changes in C(c). These improvements on cycling appeared despite that the HAIT blocks were performed as running. Reduced training time, and training transfer from running into improved cycling form, may be beneficial for cyclists living in cold climate areas.

  9. A PRACTICAL MODEL OF LOW-VOLUME HIGH-INTENSITY INTERVAL TRAINING INDUCES PERFORMANCE AND METABOLIC ADAPTATIONS THAT RESEMBLE 'ALL-OUT' SPRINT INTERVAL TRAINING

    Directory of Open Access Journals (Sweden)

    Mahdi Bayati

    2011-09-01

    Full Text Available Recently, a novel type of high-intensity interval training known as sprint interval training has demonstrated increases in aerobic and anaerobic performance with very low time commitment. However, this type of training program is unpractical for general populations. The present study compared the impact of a low-volume high-intensity interval training to a "all-out" sprint interval training. Twenty-four active young males were recruited and randomized into three groups: (G1: 3-5 cycling bouts × 30-s all-out with 4 min recovery; G2: 6- 10 cycling bouts × 125% Pmax with 2 min recovery and a non-trained control group. They all performed a VO2max test, a time to exhaustion at Pmax (Tmax and a Wingate test before and after the intervention. Capillary blood lactate was taken at rest, 3, and 20 min after the Wingate trial. Training was performed 3 sessions per week for 4 weeks. In G1, significant improvements (p < 0.05 following training were found in VO2max (9.6%, power at VO2max (12.8%, Tmax (48.4%, peak power output (10.3% and mean power output (17.1%. In G2, significant improvements following training were found in VO2max (9.7%, power at VO2max (16.1%, Tmax (54.2%, peak power output (7.4%; p < 0.05, but mean power output did not change significantly. Blood lactate recovery (20th min significantly decreased in G1 and G2 when compared with pre-testing and the CON group (p < 0.05. In conclusion, the results of the current study agree with earlier work demonstrating the effectiveness of 30-s all-out training program to aerobic and anaerobic adaptations. Of substantial interest is that the low volume high intensity training provides similar results but involves only half the intensity with double the repetitions

  10. The Efficacy of a Pre-Workout Vegan Supplement on High-Intensity Cycling Performance in Healthy College-Aged Males.

    Science.gov (United States)

    Gallien, Gabrielle; Bellar, David; Davis, Greggory R

    2017-11-02

    There is a limited supply of sport nutrition supplements currently available for vegan or vegetarian athletes. In addition, the efficacy of a vegan or vegetarian pre-workout supplement that does not contain any processed ingredients or stimulants is currently unknown. The purpose of the current study was to examine the effects of an unprocessed vegan pre-workout supplement on high-intensity cycling performance. Participants completed three separate cycling trials following the consumption of a vegan pre-workout supplement, an isocaloric processed supplement, or a zero-calorie placebo supplement. Each supplement was consumed 30 minutes prior to each trial, and each cycling trial was separated by a minimum of 72 hours. Supplements were administered using a randomized, double-blind cross-over design. Each cycling trial was performed at a workload equal to 80% VO2peak until exhaustion. The average time in seconds (s) until exhaustion values for the vegan, isocaloric, and zero-calorie supplements were 482 ± 163, 480 ± 157, and 496 ± 238, respectively. Consumption of the vegan supplement did not significantly improve performance compared to an isocaloric and zero-calorie supplement (F = 0.12, p =.89). The results of this study indicate that individuals who choose a vegan pre-workout supplement (over an isocaloric or zero-calorie product) will not experience any acute decrements or ergogenic benefits in cycling performance. Although the present study does not support performance benefits of the tested vegan pre-workout supplement before cycling, additional research examining various exercise intensities and modalities is warranted.

  11. Effects of Sprint versus High-Intensity Aerobic Interval Training on Cross-Country Mountain Biking Performance: A Randomized Controlled Trial.

    Directory of Open Access Journals (Sweden)

    Allan Inoue

    Full Text Available The current study compared the effects of high-intensity aerobic training (HIT and sprint interval training (SIT on mountain biking (MTB race simulation performance and physiological variables, including peak power output (PPO, lactate threshold (LT and onset of blood lactate accumulation (OBLA.Sixteen mountain bikers (mean ± SD: age 32.1 ± 6.4 yr, body mass 69.2 ± 5.3 kg and VO2max 63.4 ± 4.5 mL∙kg(-1∙min(-1 completed graded exercise and MTB performance tests before and after six weeks of training. The HIT (7-10 x [4-6 min--highest sustainable intensity / 4-6 min-CR100 10-15] and SIT (8-12 x [30 s--all-out intensity / 4 min--CR100 10-15] protocols were included in the participants' regular training programs three times per week.Post-training analysis showed no significant differences between training modalities (HIT vs. SIT in body mass, PPO, LT or OBLA (p = 0.30 to 0.94. The Cohen's d effect size (ES showed trivial to small effects on group factor (p = 0.00 to 0.56. The interaction between MTB race time and training modality was almost significant (p = 0.08, with a smaller ES in HIT vs. SIT training (ES = -0.43. A time main effect (pre- vs. post-phases was observed in MTB race performance and in several physiological variables (p = 0.001 to 0.046. Co-variance analysis revealed that the HIT (p = 0.043 group had significantly better MTB race performance measures than the SIT group. Furthermore, magnitude-based inferences showed HIT to be of likely greater benefit (83.5% with a lower probability of harmful effects (0.8% compared to SIT.The results of the current study suggest that six weeks of either HIT or SIT may be effective at increasing MTB race performance; however, HIT may be a preferable strategy.ClinicalTrials.gov NCT01944865.

  12. Effects of β-alanine supplementation and high-intensity interval training on endurance performance and body composition in men; a double-blind trial

    Directory of Open Access Journals (Sweden)

    Beck Travis W

    2009-02-01

    Full Text Available Abstract Background Intermittent bouts of high-intensity exercise result in diminished stores of energy substrates, followed by an accumulation of metabolites, promoting chronic physiological adaptations. In addition, β-alanine has been accepted has an effective physiological hydrogen ion (H+ buffer. Concurrent high-intensity interval training (HIIT and β-alanine supplementation may result in greater adaptations than HIIT alone. The purpose of the current study was to evaluate the effects of combining β-alanine supplementation with high-intensity interval training (HIIT on endurance performance and aerobic metabolism in recreationally active college-aged men. Methods Forty-six men (Age: 22.2 ± 2.7 yrs; Ht: 178.1 ± 7.4 cm; Wt: 78.7 ± 11.9; VO2peak: 3.3 ± 0.59 l·min-1 were assessed for peak O2 utilization (VO2peak, time to fatigue (VO2TTE, ventilatory threshold (VT, and total work done at 110% of pre-training VO2peak (TWD. In a double-blind fashion, all subjects were randomly assigned into one either a placebo (PL – 16.5 g dextrose powder per packet; n = 18 or β-alanine (BA – 1.5 g β-alanine plus 15 g dextrose powder per packet; n = 18 group. All subjects supplemented four times per day (total of 6 g/day for the first 21-days, followed by two times per day (3 g/day for the subsequent 21 days, and engaged in a total of six weeks of HIIT training consisting of 5–6 bouts of a 2:1 minute cycling work to rest ratio. Results Significant improvements in VO2peak, VO2TTE, and TWD after three weeks of training were displayed (p 2peak, VO2TTE, TWD and lean body mass were only significant for the BA group after the second three weeks of training. Conclusion The use of HIIT to induce significant aerobic improvements is effective and efficient. Chronic BA supplementation may further enhance HIIT, improving endurance performance and lean body mass.

  13. The high intensity neutron source FRANZ

    CERN Document Server

    Lederer, Claudia

    2014-01-01

    The Frankfurt neutron source of Stern Gerlach Zentrum FRANZ is currently under construction at the University of Frankfurt. At FRANZ, a high intensity neutron beam in the keV energy region will be produced by bombarding a $^7$Li target with a proton beam of several mA. These unprecedented high neutron fluxes will allow a number of neutron induced cross section measurements for the first time. Measurements can be performed by the time-of-flight and by the activation technique.

  14. Intense pulsed light-assisted facile and agile fabrication of cobalt oxide/nickel cobaltite nanoflakes on nickel-foam for high performance supercapacitor applications

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Kihun; Yu, Seongil [Department of Organic and Nano Engineering, Hanyang University, Seoul 133-791 (Korea, Republic of); Park, Sung-Hyeon [Department of Mechanical Engineering, Hanyang University, Seoul 133-791 (Korea, Republic of); Kim, Hak-Sung, E-mail: kima@hanyang.ac.kr [Department of Mechanical Engineering, Hanyang University, Seoul 133-791 (Korea, Republic of); Institute of Nano Science and Technology, Hanyang University, Seoul 133-791 (Korea, Republic of); Ahn, Heejoon, E-mail: ahn@hanyang.ac.kr [Department of Organic and Nano Engineering, Hanyang University, Seoul 133-791 (Korea, Republic of); Institute of Nano Science and Technology, Hanyang University, Seoul 133-791 (Korea, Republic of)

    2015-01-05

    Highlights: • The CoO/NiCo{sub 2}O{sub 4} nanoflakes are formed on Ni-foam substrate by IPL irradiation. • The nanoflakes are formed by IPL irradiation with an energy of 20 J cm{sup −2} for 15 ms. • The CoO/NiCo{sub 2}O{sub 4} nanoflakes exhibit a very high specific capacitance of 2163 Fg{sup −1}. • They show a good rate performance of 908 Fg{sup −1} even at 50 Ag{sup −1}. - Abstract: We report an extremely efficient method for fabricating high-performance supercapacitive CoO/NiCo{sub 2}O{sub 4} nanoflakes on Ni-foam substrate by using intense pulsed light (IPL) technology. Structural and morphological characterization is carried out using X-ray diffraction (XRD) and scanning and transmission electron microscopies (SEM and TEM). These reveal that hierarchically structured CoO/NiCo{sub 2}O{sub 4} nanoflakes of 150–200 nm in size and a thickness around 10 nm are formed on Ni-foam substrate by IPL irradiation with energy of 20 J cm{sup −2} for 15 ms. The electrochemical behavior of the composites is analyzed by cyclic voltammetry and galvanostatic charge–discharge experiments. The IPL-induced CoO/NiCo{sub 2}O{sub 4}/Ni-foam electrode exhibits a very high specific capacitance of 2163 Fg{sup −1} at a discharge current density of 1 Ag{sup −1} and a good rate performance of 908 Fg{sup −1} even at 50 Ag{sup −1}.

  15. Effect of high wavelengths low intensity light during dark period on physical exercise performance, biochemical and haematological parameters of swimming rats.

    Science.gov (United States)

    Beck, W; Gobatto, C

    2016-03-01

    Nocturnal rodents should be assessed at an appropriate time of day, which leads to a challenge in identifying an adequate environmental light which allows animal visualisation without perturbing physiological homeostasis. Thus, we analysed the influence of high wavelength and low intensity light during dark period on physical exercise and biochemical and haematological parameters of nocturnal rats. We submitted 80 animals to an exhaustive exercise at individualised intensity under two different illuminations during dark period. Red light (> 600 nm; experiments.

  16. High Intensity High Charge State ECR Ion Sources

    CERN Document Server

    Leitner, Daniela

    2005-01-01

    The next-generation heavy ion beam accelerators such as the proposed Rare Isotope Accelerator (RIA), the Radioactive Ion Beam Factory at RIKEN, the GSI upgrade project, the LHC-upgrade, and IMP in Lanzhou require a great variety of high charge state ion beams with a magnitude higher beam intensity than currently achievable. High performance Electron Cyclotron Resonance (ECR) ion sources can provide the flexibility since they can routinely produce beams from hydrogen to uranium. Over the last three decades, ECR ion sources have continued improving the available ion beam intensities by increasing the magnetic fields and ECR heating frequencies to enhance the confinement and the plasma density. With advances in superconducting magnet technology, a new generation of high field superconducting sources is now emerging, designed to meet the requirements of these next generation accelerator projects. The talk will briefly review the field of high performance ECR ion sources and the latest developments for high intens...

  17. The Effect of Financial Factors on the Performance of New Venture Companies in High Tech and Knowledge-Intensive Industries: An Empirical Study in Denmark

    DEFF Research Database (Denmark)

    Bøllingtoft, Anne; Ulhøi, John Parm; Madsen, Henning

    2003-01-01

    This paper addresses important financial aspects during the formation of knowledge-intensive entrepreneurship. A number of ex ante derived hypotheses are submitted to an empirical test to identify and explain some of the key financial factors affecting the survival and first preliminary growth...... of new ventures in high-tech and knowledge-intensive sectors. The paper builds in part upon existing literature on venture capital, theory on risk and trust. The results document that high variation on several dimensions can be found across the two sectors investigated (IT and life sciences)....

  18. High intensity specular reflectometry - first experiments

    CERN Document Server

    Stahn, J; Panzner, T

    2011-01-01

    Selene is the attempt to implement a new scheme for high-intensity specular reflectometry. Instead of a highly collimated beam one uses a convergent beam covering a large angular range. The angular resolution is then performed by a position-sensitive detector. Off-specular scattering in this set-up leads to some background, but for screening of wide parameter ranges (e.g. temperature, electric and magnetic fields) the intensity gain of at least one order of magnitude is essential. If necessary, the high precession measurements (even with off-specular components) then are performed with the conventional set-up. The heart of this new set-up is an elliptically focusing guide element of 2\\,m length. Though this guide is optimised for the use on the TOF reflectometer Amor at SINQ, it can be used as stand-alone device to check the possible application also for other neutron scattering techniques. The first measurements on AMOR confirmed the general concept and the various operation modes. A draw-back occurred due t...

  19. High Intensity Secondary Beams Driven by Protons

    CERN Document Server

    Galambos, John; Nagaitsev, Sergei

    2013-01-01

    As part of the Intensity Frontier effort within the 2013 Community Summer Study, a workshop on the proton machine capabilities was held (High Intensity Secondary Beams Driven by Proton Beams) April 17-20, 2013 at Brookhaven National Laboratory in Upton, NY. Primary aims of the workshop were to understand: 1) the beam requirements for proposed high intensity proton beam based measurements; 2) the capabilities of existing world-wide high power proton machines; 3) proton facility upgrade plans and proposals for new facilities; 4) and to document the R&D needs for proton accelerators and target systems needed to support proposed intensity frontier measurements. These questions are addressed in this summary.

  20. Resveratrol supplementation does not augment performance adaptations or fibre-type-specific responses to high-intensity interval training in humans.

    Science.gov (United States)

    Scribbans, Trisha D; Ma, Jasmin K; Edgett, Brittany A; Vorobej, Kira A; Mitchell, Andrew S; Zelt, Jason G E; Simpson, Craig A; Quadrilatero, Joe; Gurd, Brendon J

    2014-11-01

    The present study examined the effect of concurrent exercise training and daily resveratrol (RSV) supplementation (150 mg) on training-induced adaptations following low-dose high-intensity interval training (HIIT). Sixteen recreationally active (∼22 years, ∼51 mL·kg(-1)·min(-1)) men were randomly assigned in a double-blind fashion to either the RSV or placebo group with both groups performing 4 weeks of HIIT 3 days per week. Before and after training, participants had a resting muscle biopsy taken, completed a peak oxygen uptake test, a Wingate test, and a submaximal exercise test. A main effect of training (p training (p training: 54.5 ± 1.5 mL·kg(-1)·min(-1), effect size (ES) = 0.93; RSV - pretraining: 49.6 ± 2.2, post-training: 52.3 ± 2.5 mL·kg(-1)·min(-1), ES = 0.50) and Wingate peak power (placebo: pretraining: 747 ± 39, post-training: 809 ± 31 W, ES = 0.84; RSV - pretraining: 679 ± 39, post-training: 691 ± 43 W, ES = 0.12). Fibre-type distribution was unchanged, while a main effect of training (p training was significantly (p training and RSV supplementation may alter the normal training response induced by low-volume HIIT.

  1. Photoproduction at High Energy and High Intensity

    CERN Multimedia

    2002-01-01

    The photon beam used for this programme is tagged and provides a large flux up to very high energies (150-200 GeV). It is also hadron-free, since it is obtained by a two-step conversion method. A spectrometer is designed to exploit this beam and to perform a programme of photoproduction with a high level of sensitivity (5-50 events/picobarn).\\\\ \\\\ Priority will be given to the study of processes exhibiting the point-like behaviour of the photon, especially deep inelastic Compton scattering. The spectrometer has two magnets. Charged tracks are measured by MWPC's located only in field-free regions. Three calorimeters provide a large coverage for identifying and measuring electrons and photons. An iron filter downstream identifies muons. Most of the equipment is existing and recuperated from previous experiments.

  2. High intensity polarized electron sources

    Energy Technology Data Exchange (ETDEWEB)

    Sinclair, C.K.

    1980-10-01

    The status of the polarized electron source development program at SLAC will be reviewed. Emission currents of 60 A, corresponding to a space charge limited current density of 180 A/cm/sup 2/, have been obtained from GaAs photocathodes. Electron beam polarization 20% greater than that obtainable from GaAs cathodes has been observed from multilayer GaAs-GaAlAs structures. Work in progress to produce high beam polarization from II-IV-V/sub 2/ chalcopyrite photocathodes will also be described.

  3. High-Intensity Proton Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Jay L. Hirshfield

    2011-12-27

    Analysis is presented for an eight-cavity proton cyclotron accelerator that could have advantages as compared with other accelerators because of its potentially high acceleration gradient. The high gradient is possible since protons orbit in a sequence of TE111 rotating mode cavities of equally diminishing frequencies with path lengths during acceleration that greatly exceed the cavity lengths. As the cavities operate at sequential harmonics of a basic repetition frequency, phase synchronism can be maintained over a relatively wide injection phase window without undue beam emittance growth. It is shown that use of radial vanes can allow cavity designs with significantly smaller radii, as compared with simple cylindrical cavities. Preliminary beam transport studies show that acceptable extraction and focusing of a proton beam after cyclic motion in this accelerator should be possible. Progress is also reported on design and tests of a four-cavity electron counterpart accelerator for experiments to study effects on beam quality arising from variations injection phase window width. This device is powered by four 500-MW pulsed amplifiers at 1500, 1800, 2100, and 2400 MHz that provide phase synchronous outputs, since they are driven from a with harmonics derived from a phase-locked 300 MHz source.

  4. Post-exercise cold water immersion does not alter high intensity interval training-induced exercise performance and Hsp72 responses, but enhances mitochondrial markers.

    Science.gov (United States)

    Aguiar, Paula Fernandes; Magalhães, Sílvia Mourão; Fonseca, Ivana Alice Teixeira; da Costa Santos, Vanessa Batista; de Matos, Mariana Aguiar; Peixoto, Marco Fabrício Dias; Nakamura, Fábio Yuzo; Crandall, Craig; Araújo, Hygor Nunes; Silveira, Leonardo Reis; Rocha-Vieira, Etel; de Castro Magalhães, Flávio; Amorim, Fabiano Trigueiro

    2016-09-01

    This study aims to evaluate the effect of regular post-exercise cold water immersion (CWI) on intramuscular markers of cellular stress response and signaling molecules related to mitochondria biogenesis and exercise performance after 4 weeks of high intensity interval training (HIIT). Seventeen healthy subjects were allocated into two groups: control (CON, n = 9) or CWI (n = 8). Each HIIT session consisted of 8-12 cycling exercise stimuli (90-110 % of peak power) for 60 s followed by 75 s of active recovery three times per week, for 4 weeks (12 HIIT sessions). After each HIIT session, the CWI had their lower limbs immersed in cold water (10 °C) for 15 min and the CON recovered at room temperature. Exercise performance was evaluated before and after HIIT by a 15-km cycling time trial. Vastus lateralis biopsies were obtained pre and 72 h post training. Samples were analyzed for heat shock protein 72 kDa (Hsp72), adenosine monophosphate-activated protein kinase (AMPK), and phosphorylated p38 mitogen-activated protein kinase (p-p38 MAPK) assessed by western blot. In addition, the mRNA expression of heat shock factor-1 (HSF-1), peroxisome proliferator-activated receptor gamma coactivator-1α (PGC-1α), nuclear respiratory factor 1 and 2 (NRF1 and 2), mitochondrial transcription factor A (Tfam), calcium calmodulin-dependent protein kinase 2 (CaMK2) and enzymes citrate synthase (CS), carnitine palmitoyltransferase I (CPT1), and pyruvate dehydrogenase kinase (PDK4) were assessed by real-time PCR. Time to complete the 15-km cycling time trial was reduced with training (p  0.05). No differences were observed with training or condition for mRNA expression of PGC-1α (p = 0.31), CPT1 (p = 0.14), CS (p = 0.44), and NRF-2 (p = 0.82). However, HFS-1 (p = 0.007), PDK4 (p = 0.03), and Tfam (p = 0.03) mRNA were higher in CWI. NRF-1 decrease in both groups after training (p = 0.006). CaMK2 decreased with HIIT (p = 0.003) but

  5. The use of water immersion as a recovery intervention following high-intensity excercise : an investigation of the physiological and performance effects

    OpenAIRE

    Crampton, David

    2012-01-01

    Despite the lack of a clear scientific basis for its usage, cold water immersion (CWI) and contrast water therapy (CWT) are commonly used recovery interventions in elite sport. Anecdotally, a number of theoretical benefits have been advanced to support the use of water immersion, including the suggestion that CWI and/or CWT facilitate lactate clearance following high-intensity exercise. Therefore, the primary aim of this thesis was to investigate the effect of different water immersion protoc...

  6. High Intensity Exercise in Multiple Sclerosis

    DEFF Research Database (Denmark)

    Wens, Inez; Dalgas, Ulrik; Vandenabeele, Frank

    2015-01-01

    Introduction Low-to-moderate intensity exercise improves muscle contractile properties and endurance capacity in multiple sclerosis (MS). The impact of high intensity exercise remains unknown. Methods Thirty-four MS patients were randomized into a sedentary control group (SED, n = 11) and 2...

  7. Performance, Performance System, and High Performance System

    Science.gov (United States)

    Jang, Hwan Young

    2009-01-01

    This article proposes needed transitions in the field of human performance technology. The following three transitions are discussed: transitioning from training to performance, transitioning from performance to performance system, and transitioning from learning organization to high performance system. A proposed framework that comprises…

  8. Stretching Effects: High-intensity & Moderate-duration vs. Low-intensity & Long-duration.

    Science.gov (United States)

    Freitas, S R; Vaz, J R; Bruno, P M; Andrade, R; Mil-Homens, P

    2016-03-01

    This study examined whether a high-intensity, moderate-duration bout of stretching would produce the same acute effects as a low-intensity, long-duration bout of stretching. 17 volunteers performed 2 knee-flexor stretching protocols: a high-intensity stretch (i. e., 100% of maximum tolerable passive torque) with a moderate duration (243.5 ± 69.5-s); and a low-intensity stretch (50% of tolerable passive torque) with a long duration (900-s). Passive torque at a given sub-maximal angle, peak passive torque, maximal range of motion (ROM), and muscle activity were assessed before and after each stretching protocol (at intervals of 1, 30 and 60 min). The maximal ROM and tolerable passive torque increased for all time points following the high-intensity stretching (p0.05). 1 min post-stretching, the passive torque decreased in both protocols, but to a greater extent in the low-intensity protocol. 30 min post-test, torque returned to baseline for the low-intensity protocol and had increased above the baseline for the high-intensity stretches. The following can be concluded: 1) High-intensity stretching increases the maximal ROM and peak passive torque compared to low-intensity stretching; 2) low-intensity, long-duration stretching is the best way to acutely decrease passive torque; and 3) high-intensity, moderate-duration stretching increases passive torque above the baseline 30 min after stretching. © Georg Thieme Verlag KG Stuttgart · New York.

  9. The effects of a pre-workout supplement containing caffeine, creatine, and amino acids during three weeks of high-intensity exercise on aerobic and anaerobic performance.

    Science.gov (United States)

    Smith, Abbie E; Fukuda, David H; Kendall, Kristina L; Stout, Jeffrey R

    2010-02-15

    A randomized, single-blinded, placebo-controlled, parallel design study was used to examine the effects of a pre-workout supplement combined with three weeks of high-intensity interval training (HIIT) on aerobic and anaerobic running performance, training volume, and body composition. Twenty-four moderately-trained recreational athletes (mean +/- SD age = 21.1 +/- 1.9 yrs; stature = 172.2 +/- 8.7 cm; body mass = 66.2 +/- 11.8 kg, VO2max = 3.21 +/- 0.85 l.min-1, percent body fat = 19.0 +/- 7.1%) were assigned to either the active supplement (GT, n = 13) or placebo (PL, n = 11) group. The active supplement (Game Time(R), Corr-Jensen Laboratories Inc., Aurora, CO) was 18 g of powder, 40 kcals, and consisted of a proprietary blend including whey protein, cordyceps sinensis, creatine, citrulline, ginseng, and caffeine. The PL was also 18 g of powder, 40 kcals, and consisted of only maltodextrin, natural and artificial flavors and colors. Thirty minutes prior to all testing and training sessions, participants consumed their respective supplements mixed with 8-10 oz of water. Both groups participated in a three-week HIIT program three days per week, and testing was conducted before and after the training. Cardiovascular fitness (VO2max) was assessed using open circuit spirometry (Parvo-Medics TrueOne(R) 2400 Metabolic Measurement System, Sandy, UT) during graded exercise tests on a treadmill (Woodway, Pro Series, Waukesha, WI). Also, four high-speed runs to exhaustion were conducted at 110, 105, 100, and 90% of the treadmill velocity recorded during VO2max, and the distances achieved were plotted over the times-to-exhaustion. Linear regression was used to determine the slopes (critical velocity, CV) and y-intercepts (anaerobic running capacity, ARC) of these relationships to assess aerobic and anaerobic performances, respectively. Training volumes were tracked by summing the distances achieved during each training session for each subject. Percent body fat (%BF) and lean

  10. The effects of a pre-workout supplement containing caffeine, creatine, and amino acids during three weeks of high-intensity exercise on aerobic and anaerobic performance

    Directory of Open Access Journals (Sweden)

    Kendall Kristina L

    2010-02-01

    Full Text Available Abstract Background A randomized, single-blinded, placebo-controlled, parallel design study was used to examine the effects of a pre-workout supplement combined with three weeks of high-intensity interval training (HIIT on aerobic and anaerobic running performance, training volume, and body composition. Methods Twenty-four moderately-trained recreational athletes (mean ± SD age = 21.1 ± 1.9 yrs; stature = 172.2 ± 8.7 cm; body mass = 66.2 ± 11.8 kg, VO2max = 3.21 ± 0.85 l·min-1, percent body fat = 19.0 ± 7.1% were assigned to either the active supplement (GT, n = 13 or placebo (PL, n = 11 group. The active supplement (Game Time®, Corr-Jensen Laboratories Inc., Aurora, CO was 18 g of powder, 40 kcals, and consisted of a proprietary blend including whey protein, cordyceps sinensis, creatine, citrulline, ginseng, and caffeine. The PL was also 18 g of powder, 40 kcals, and consisted of only maltodextrin, natural and artificial flavors and colors. Thirty minutes prior to all testing and training sessions, participants consumed their respective supplements mixed with 8-10 oz of water. Both groups participated in a three-week HIIT program three days per week, and testing was conducted before and after the training. Cardiovascular fitness (VO2max was assessed using open circuit spirometry (Parvo-Medics TrueOne® 2400 Metabolic Measurement System, Sandy, UT during graded exercise tests on a treadmill (Woodway, Pro Series, Waukesha, WI. Also, four high-speed runs to exhaustion were conducted at 110, 105, 100, and 90% of the treadmill velocity recorded during VO2max, and the distances achieved were plotted over the times-to-exhaustion. Linear regression was used to determine the slopes (critical velocity, CV and y-intercepts (anaerobic running capacity, ARC of these relationships to assess aerobic and anaerobic performances, respectively. Training volumes were tracked by summing the distances achieved during each training session for each subject

  11. Short and Long Term Effects of High-Intensity Interval Training on Hormones, Metabolites, Antioxidant System, Glycogen Concentration, and Aerobic Performance Adaptations in Rats.

    Science.gov (United States)

    de Araujo, Gustavo G; Papoti, Marcelo; Dos Reis, Ivan Gustavo Masselli; de Mello, Maria A R; Gobatto, Claudio A

    2016-01-01

    The purpose of the study was to investigate the effects of short and long term High-Intensity Interval Training (HIIT) on anaerobic and aerobic performance, creatinine, uric acid, urea, creatine kinase, lactate dehydrogenase, catalase, superoxide dismutase, testosterone, corticosterone, and glycogen concentration (liver, soleus, and gastrocnemius). The Wistar rats were separated in two groups: HIIT and sedentary/control (CT). The lactate minimum (LM) was used to evaluate the aerobic and anaerobic performance (AP) (baseline, 6, and 12 weeks). The lactate peak determination consisted of two swim bouts at 13% of body weight (bw): (1) 30 s of effort; (2) 30 s of passive recovery; (3) exercise until exhaustion (AP). Tethered loads equivalent to 3.5, 4.0, 4.5, 5.0, 5.5, and 6.5% bw were performed in incremental phase. The aerobic capacity in HIIT group increased after 12 weeks (5.2 ± 0.2% bw) in relation to baseline (4.4 ± 0.2% bw), but not after 6 weeks (4.5 ± 0.3% bw). The exhaustion time in HIIT group showed higher values than CT after 6 (HIIT = 58 ± 5 s; CT = 40 ± 7 s) and 12 weeks (HIIT = 62 ± 7 s; CT = 49 ± 3 s). Glycogen (mg/100 mg) increased in gastrocnemius for HIIT group after 6 weeks (0.757 ± 0.076) and 12 weeks (1.014 ± 0.157) in comparison to baseline (0.358 ± 0.024). In soleus, the HIIT increased glycogen after 6 weeks (0.738 ± 0.057) and 12 weeks (0.709 ± 0.085) in comparison to baseline (0.417 ± 0.035). The glycogen in liver increased after HIIT 12 weeks (4.079 ± 0.319) in relation to baseline (2.400 ± 0.416). The corticosterone (ng/mL) in HIIT increased after 6 weeks (529.0 ± 30.5) and reduced after 12 weeks (153.6 ± 14.5) in comparison to baseline (370.0 ± 18.3). In conclusion, long term HIIT enhanced the aerobic capacity, but short term was not enough to cause aerobic adaptations. The anaerobic performance increased in HIIT short and long term compared with CT, without differences between HIIT short and long term. Furthermore, the

  12. SHORT AND LONG TERM EFFECTS OF HIGH-INTENSITY INTERVAL TRAINING ON HORMONES, METABOLITES, ANTIOXIDANT SYSTEM, GLYCOGEN CONCENTRATION AND AEROBIC PERFORMANCE ADAPTATIONS IN RATS

    Directory of Open Access Journals (Sweden)

    Gustavo Gomes De Araujo

    2016-10-01

    Full Text Available The purpose of the study was to investigate the effects of short and long term High-Intensity Interval Training (HIIT on anaerobic and aerobic performance, creatinine, uric acid, urea, creatine kinase, lactate dehydrogenase, catalase, superoxide dismutase, testosterone, corticosterone and glycogen concentration (liver, soleus and gastrocnemius. The Wistar were separated in two groups: HIIT and sedentary/control (CT. The lactate minimum (LM was used to evaluate the aerobic and anaerobic performance (AP (baseline, 6 and 12 wk. The lactate peak determination consisted of two swim bouts at 13% of body weight (bw: 1 30 s of effort; 2 30 s of passive recovery; 3 exercise until exhaustion (AP. Tethered loads equivalent to 3.5, 4.0, 4.5, 5.0, 5.5 and 6.5% bw were performed in incremental phase. The aerobic capacity in HIIT group increased after 12 wk (5.2±0.2 % bw in relation to baseline (4.4±0.2 % bw, but not after 6 wk (4.5±0.3 % bw. The exhaustion time in HIIT group showed higher values than CT after 6 (HIIT= 58±5 s; CT=40±7 s and 12 wk (HIIT=62±7 s; CT=49±3 s. Glycogen (mg/100mg increased in gastrocnemius for HIIT group after 6 wk (0.757±0.076 and 12 wk (1.014±0.157 in comparison to baseline (0.358±0.024. In soleus, the HIIT increased glycogen after 6 wk (0.738±0.057 and 12 wk (0.709±0.085 in comparison to baseline (0.417±0.035. The glycogen in liver increased after HIIT 12 wk (4.079±0.319 in relation to baseline (2.400±0.416. The corticosterone (ng/mL in HIIT increased after 6 wk (529.0±30.5 and reduced after 12 wk (153.6±14.5 in comparison to baseline (370.0±18.3. In conclusion, long term HIIT enhanced the aerobic capacity, but short term (6wk was not enough to cause aerobic adaptations. The anaerobic performance increased in HIIT short and long term compared with CT, without differences between HIIT short and long term. Furthermore, the glycogen super-compensantion increased after short and long term HIIT in comparison to

  13. Scientific Opinion on the substantiation of a health claim related to beta-alanine and increase in physical performance during short-duration, high-intensity exercise pursuant to Article 13(5 of Regulation (EC No 1924/2006

    Directory of Open Access Journals (Sweden)

    EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA

    2014-07-01

    Full Text Available Following an application from Natural Alternative International, Inc. (NAI, submitted pursuant to Article 13(5 of Regulation (EC No 1924/2006 via the Competent Authority of the United Kingdom, the Panel on Dietetic Products, Nutrition and Allergies (NDA was asked to deliver an opinion on the scientific substantiation of a health claim related to beta-alanine and increase in physical performance during short-duration, high-intensity exercise. The food constituent that is the subject of the claim is beta-alanine, which is sufficiently characterised. The Panel considers that an increase in physical performance during short-duration, high-intensity exercise is a beneficial physiological effect. In weighing the evidence the Panel took into account that only one out of 11 pertinent human intervention studies (including 14 pertinent outcomes from which conclusions could be drawn showed an effect of beta-alanine on physical performance during short-duration, high intensity exercise. The Panel concludes that a cause and effect relationship has not been established between the consumption of beta-alanine and an increase in physical performance during short-duration, high intensity exercise.

  14. High intensity neutrino oscillation facilities in Europe

    CERN Document Server

    Edgecock, T R; Davenne, T; Densham, C; Fitton, M; Kelliher, D; Loveridge, P; Machida, S; Prior, C; Rogers, C; Rooney, M; Thomason, J; Wilcox, D; Wildner, E; Efthymiopoulos, I; Garoby, R; Gilardoni, S; Hansen, C; Benedetto, E; Jensen, E; Kosmicki, A; Martini, M; Osborne, J; Prior, G; Stora, T; Melo-Mendonca, T; Vlachoudis, V; Waaijer, C; Cupial, P; Chancé, A; Longhin, A; Payet, J; Zito, M; Baussan, E; Bobeth, C; Bouquerel, E; Dracos, M; Gaudiot, G; Lepers, B; Osswald, F; Poussot, P; Vassilopoulos, N; Wurtz, J; Zeter, V; Bielski, J; Kozien, M; Lacny, L; Skoczen, B; Szybinski, B; Ustrycka, A; Wroblewski, A; Marie-Jeanne, M; Balint, P; Fourel, C; Giraud, J; Jacob, J; Lamy, T; Latrasse, L; Sortais, P; Thuillier, T; Mitrofanov, S; Loiselet, M; Keutgen, Th; Delbar, Th; Debray, F; Trophine, C; Veys, S; Daversin, C; Zorin, V; Izotov, I; Skalyga, V; Burt, G; Dexter, A C; Kravchuk, V L; Marchi, T; Cinausero, M; Gramegna, F; De Angelis, G; Prete, G; Collazuol, G; Laveder, M; Mazzocco, M; Mezzetto, M; Signorini, C; Vardaci, E; Di Nitto, A; Brondi, A; La Rana, G; Migliozzi, P; Moro, R; Palladino, V; Gelli, N; Berkovits, D; Hass, M; Hirsh, T Y; Schaumann, M; Stahl, A; Wehner, J; Bross, A; Kopp, J; Neuffer, D; Wands, R; Bayes, R; Laing, A; Soler, P; Agarwalla, S K; Villanueva, A Cervera; Donini, A; Ghosh, T; Cadenas, J J Gómez; Hernández, P; Martín-Albo, J; Mena, O; Burguet-Castell, J; Agostino, L; Buizza-Avanzini, M; Marafini, M; Patzak, T; Tonazzo, A; Duchesneau, D; Mosca, L; Bogomilov, M; Karadzhov, Y; Matev, R; Tsenov, R; Akhmedov, E; Blennow, M; Lindner, M; Schwetz, T; Martinez, E Fernández; Maltoni, M; Menéndez, J; Giunti, C; García, M C González; Salvado, J; Coloma, P; Huber, P; Li, T; López-Pavón, J; Orme, C; Pascoli, S; Meloni, D; Tang, J; Winter, W; Ohlsson, T; Zhang, H; Scotto-Lavina, L; Terranova, F; Bonesini, M; Tortora, L; Alekou, A; Aslaninejad, M; Bontoiu, C; Kurup, A; Jenner, L J; Long, K; Pasternak, J; Pozimski, J; Back, J J; Harrison, P; Beard, K; Bogacz, A; Berg, J S; Stratakis, D; Witte, H; Snopok, P; Bliss, N; Cordwell, M; Moss, A; Pattalwar, S; Apollonio, M

    2013-01-01

    The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fr\\'ejus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of {\\mu}+ and {\\mu}- beams in a storage ring. The far detector in this case is a 100 kt Magnetised Iron Neutrino Detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular 6He and 18Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fr\\'ejus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the ph...

  15. High intensity neutrino oscillation facilities in Europe

    CERN Document Server

    Edgecock, T.R.; Davenne, T.; Densham, C.; Fitton, M.; Kelliher, D.; Loveridge, P.; Machida, S.; Prior, C.; Rogers, C.; Rooney, M.; Thomason, J.; Wilcox, D.; Wildner, E.; Efthymiopoulos, I.; Garoby, R.; Gilardoni, S.; Hansen, C.; Benedetto, E.; Jensen, E.; Kosmicki, A.; Martini, M.; Osborne, J.; Prior, G.; Stora, T.; Melo-Mendonca, T.; Vlachoudis, V.; Waaijer, C.; Cupial, P.; Chancé, A.; Longhin, A.; Payet, J.; Zito, M.; Baussan, E.; Bobeth, C.; Bouquerel, E.; Dracos, M.; Gaudiot, G.; Lepers, B.; Osswald, F.; Poussot, P.; Vassilopoulos, N.; Wurtz, J.; Zeter, V.; Bielski, J.; Kozien, M.; Lacny, L.; Skoczen, B.; Szybinski, B.; Ustrzycka, A.; Wroblewski, A.; Marie-Jeanne, M.; Balint, P.; Fourel, C.; Giraud, J.; Jacob, J.; Lamy, T.; Latrasse, L.; Sortais, P.; Thuillier, T.; Mitrofanov, S.; Loiselet, M.; Keutgen, Th.; Delbar, Th.; Debray, F.; Trophine, C.; Veys, S.; Daversin, C.; Zorin, V.; Izotov, I.; Skalyga, V.; Burt, G.; Dexter, A.C.; Kravchuk, V.L.; Marchi, T.; Cinausero, M.; Gramegna, F.; De Angelis, G.; Prete, G.; Collazuol, G.; Laveder, M.; Mazzocco, M.; Mezzetto, M.; Signorini, C.; Vardaci, E.; Di Nitto, A.; Brondi, A.; La Rana, G.; Migliozzi, P.; Moro, R.; Palladino, V.; Gelli, N.; Berkovits, D.; Hass, M.; Hirsh, T.Y.; Schaumann, M.; Stahl, A.; Wehner, J.; Bross, A.; Kopp, J.; Neuffer, D.; Wands, R.; Bayes, R.; Laing, A.; Soler, P.; Agarwalla, S.K.; Cervera Villanueva, A.; Donini, A.; Ghosh, T.; Gómez Cadenas, J.J.; Hernández, P.; Martín-Albo, J.; Mena, O.; Burguet-Castell, J.; Agostino, L.; Buizza-Avanzini, M.; Marafini, M.; Patzak, T.; Tonazzo, A.; Duchesneau, D.; Mosca, L.; Bogomilov, M.; Karadzhov, Y.; Matev, R.; Tsenov, R.; Akhmedov, E.; Blennow, M.; Lindner, M.; Schwetz, T.; Fernández Martinez, E.; Maltoni, M.; Menéndez, J.; Giunti, C.; González García, M. C.; Salvado, J.; Coloma, P.; Huber, P.; Li, T.; López-Pavón, J.; Orme, C.; Pascoli, S.; Meloni, D.; Tang, J.; Winter, W.; Ohlsson, T.; Zhang, H.; Scotto-Lavina, L.; Terranova, F.; Bonesini, M.; Tortora, L.; Alekou, A.; Aslaninejad, M.; Bontoiu, C.; Kurup, A.; Jenner, L.J.; Long, K.; Pasternak, J.; Pozimski, J.; Back, J.J.; Harrison, P.; Beard, K.; Bogacz, A.; Berg, J.S.; Stratakis, D.; Witte, H.; Snopok, P.; Bliss, N.; Cordwell, M.; Moss, A.; Pattalwar, S.; Apollonio, M.

    2013-02-20

    The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fr\\'ejus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of {\\mu}+ and {\\mu}- beams in a storage ring. The far detector in this case is a 100 kt Magnetised Iron Neutrino Detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular 6He and 18Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fr\\'ejus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the ph...

  16. High intensity neutrino oscillation facilities in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Edgecock, T. R.; Caretta, O.; Davenne, T.; Densam, C.; Fitton, M.; Kelliher, D.; Loveridge, P.; Machida, S.; Prior, C.; Rogers, C.; Rooney, M.; Thomason, J.; Wilcox, D.; Wildner, E.; Efthymiopoulos, I.; Garoby, R.; Gilardoni, S.; Hansen, C.; Benedetto, E.; Jensen, E.; Kosmicki, A.; Martini, M.; Osborne, J.; Prior, G.; Stora, T.; Melo Mendonca, T.; Vlachoudis, V.; Waaijer, C.; Cupial, P.; Chancé, A.; Longhin, A.; Payet, J.; Zito, M.; Baussan, E.; Bobeth, C.; Bouquerel, E.; Dracos, M.; Gaudiot, G.; Lepers, B.; Osswald, F.; Poussot, P.; Vassilopoulos, N.; Wurtz, J.; Zeter, V.; Bielski, J.; Kozien, M.; Lacny, L.; Skoczen, B.; Szybinski, B.; Ustrycka, A.; Wroblewski, A.; Marie-Jeanne, M.; Balint, P.; Fourel, C.; Giraud, J.; Jacob, J.; Lamy, T.; Latrasse, L.; Sortais, P.; Thuillier, T.; Mitrofanov, S.; Loiselet, M.; Keutgen, Th.; Delbar, Th.; Debray, F.; Trophine, C.; Veys, S.; Daversin, C.; Zorin, V.; Izotov, I.; Skalyga, V.; Burt, G.; Dexter, A. C.; Kravchuk, V. L.; Marchi, T.; Cinausero, M.; Gramegna, F.; De Angelis, G.; Prete, G.; Collazuol, G.; Laveder, M.; Mazzocco, M.; Mezzetto, M.; Signorini, C.; Vardaci, E.; Di Nitto, A.; Brondi, A.; La Rana, G.; Migliozzi, P.; Moro, R.; Palladino, V.; Gelli, N.; Berkovits, D.; Hass, M.; Hirsh, T. Y.; Schaumann, M.; Stahl, A.; Wehner, J.; Bross, A.; Kopp, J.; Neuffer, D.; Wands, R.; Bayes, R.; Laing, A.; Soler, P.; Agarwalla, S. K.; Cervera Villanueva, A.; Donini, A.; Ghosh, T.; Gómez Cadenas, J. J.; Hernández, P.; Martín-Albo, J.; Mena, O.; Burguet-Castell, J.; Agostino, L.; Buizza-Avanzini, M.; Marafini, M.; Patzak, T.; Tonazzo, A.; Duchesneau, D.; Mosca, L.; Bogomilov, M.; Karadzhov, Y.; Matev, R.; Tsenov, R.; Akhmedov, E.; Blennow, M.; Lindner, M.; Schwetz, T.; Fernández Martinez, E.; Maltoni, M.; Menéndez, J.; Giunti, C.; González García, M. C.; Salvado, J.; Coloma, P.; Huber, P.; Li, T.; López Pavón, J.; Orme, C.; Pascoli, S.; Meloni, D.; Tang, J.; Winter, W.; Ohlsson, T.; Zhang, H.; Scotto-Lavina, L.; Terranova, F.; Bonesini, M.; Tortora, L.; Alekou, A.; Aslaninejad, M.; Bontoiu, C.; Kurup, A.; Jenner, L. J.; Long, K.; Pasternak, J.; Pozimski, J.; Back, J. J.; Harrison, P.; Beard, K.; Bogacz, A.; Berg, J. S.; Stratakis, D.; Witte, H.; Snopok, P.; Bliss, N.; Cordwell, M.; Moss, A.; Pattalwar, S.; Apollonio, M.

    2013-02-01

    The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fr\\'ejus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of {\\mu}+ and {\\mu}- beams in a storage ring. The far detector in this case is a 100 kt Magnetised Iron Neutrino Detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular 6He and 18Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fr\\'ejus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the physics reach of each facility, in particular for the measurement of CP violation in the lepton sector, and estimated the cost of construction. These have demonstrated that the best facility to build is the Neutrino Factory. However, if a powerful proton driver is constructed for another purpose or if the MEMPHYS detector is built for astroparticle physics, the Super Beam also becomes very attractive.

  17. High-Intensity Synchrotron Radiation Effects

    CERN Document Server

    Suetsugu, Y

    2016-01-01

    Various effects of intense synchrotron radiation on the performance of particle accelerators, especially for storage rings, are discussed. Following a brief introduction to synchrotron radiation, the basic concepts of heat load, gas load, electron emission, and the countermeasures against these effects are discussed.

  18. Correlation between athlete training intensity and cardiac performance

    African Journals Online (AJOL)

    2016-09-03

    Sep 3, 2016 ... Key words: Athlete, cardiac performance, correlation, training intensity ... Therefore, these two substances are important indicators to monitor intensity of .... conditions, athletes' energy can be enhanced, glycogen in the body ...

  19. Trading intensity and real estate performance

    NARCIS (Netherlands)

    D. Brounen (Dirk); P.M.A. Eichholtz (Piet); D. Ling (David)

    2007-01-01

    textabstractThis paper investigates whether it is possible to create value through the active management of direct property portfolios. Using data from the USA, the UK and Australia, we examine whether trading intensity and portfolio growth explain the risk and return characteristics of listed prope

  20. Stimulated Raman backscattering at high laser intensities

    Energy Technology Data Exchange (ETDEWEB)

    Skoric, M.M. [Vinca Inst. of Nuclear Sciences, Belgrade (Yugoslavia); Tajima, Toshiki; Sasaki, Akira; Maluckov, A.; Jovanovic, M.

    1998-03-01

    Signatures of Stimulated Raman backscattering of a short-pulse high-intensity laser interacting with an underdense plasma are discussed. We introduce a nonlinear three-wave interaction model that accounts for laser pump depletion and relativistic detuning. A mechanism is revealed based on a generic route to chaos, that predicts a progressive increase of the backscatter complexity with a growing laser intensity. Importance of kinetic effects is outlined and demonstrated in fluid-hybrid and particle simulations. As an application, we show that spectral anomalies of the backscatter, predicted by the above model, are consistent with recent sub-picosecond, high-intensity laser gas-target measurements at Livermore and elsewhere. Finally, a recently proposed scheme for generation of ultra-short, low-prepulse laser pulses by Raman backscattering in a thin foil target, is shown. (author)

  1. High-intensity, focused ultrasonic fields

    DEFF Research Database (Denmark)

    Jensen, Leif Bjørnø

    1988-01-01

    distribution, etc. involving nonlinearity, diffraction, and absorption in the high-intensity focused ultrasonic fields produced by an ellipsoid as well as a spherical cap focusing geometry. Data from the development of an ESWL of the piezoelectric disk type are reported including demands to transducers...

  2. Cryogenic semiconductor high-intensity radiation monitors

    CERN Document Server

    Palmieri, V G; Borer, K; Casagrande, L; Da Vià, C; Devine, S R H; Dezillie, B; Esposito, A; Granata, V; Hauler, F; Jungermann, L; Li, Z; Lourenço, C; Niinikoski, T O; O'Shea, V

    2003-01-01

    This paper describes a novel technique to monitor high-intensity particle beams by means of a semiconductor detector. It consists of cooling a semiconductor detector down to cryogenic temperature to suppress the thermally generated leakage current and to precisely measure the integrated ionization signal. It will be shown that such a device provides very good linearity and a dynamic range wider than is possible with existing techniques. Moreover, thanks to the Lazarus effect, extreme radiation hardness can be achieved providing in turn absolute intensity measurements against precise calibration of the device at low beam flux.

  3. Department of Energy Project ER25739 Final Report QoS-Enabled, High-performance Storage Systems for Data-Intensive Scientific Computing

    Energy Technology Data Exchange (ETDEWEB)

    Rangaswami, Raju

    2009-05-31

    This project's work resulted in the following research projects: (1) BORG - Block-reORGanization for Self-optimizing Storage Systems; (2) ABLE - Active Block Layer Extensions; (3) EXCES - EXternal Caching in Energy-Saving Storage Systems; (4) GRIO - Guaranteed-Rate I/O Scheduler. These projects together help in substantially advancing the over-arching project goal of developing 'QoS-Enabled, High-Performance Storage Systems'.

  4. High intensity neutrino oscillation facilities in Europe

    Directory of Open Access Journals (Sweden)

    T. R. Edgecock

    2013-02-01

    Full Text Available The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fréjus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of μ^{+} and μ^{-} beams in a storage ring. The far detector in this case is a 100 kt magnetized iron neutrino detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular ^{6}He and ^{18}Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fréjus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the physics reach of each facility, in particular for the measurement of CP violation in the lepton sector, and estimated the cost of construction. These have demonstrated that the best facility to build is the Neutrino Factory. However, if a powerful proton driver is constructed for another purpose or if the MEMPHYS detector is built for astroparticle physics, the Super Beam also becomes very attractive.

  5. The positive effects of priming exercise on oxygen uptake kinetics and high-intensity exercise performance are not magnified by a fast-start pacing strategy in trained cyclists.

    Science.gov (United States)

    Caritá, Renato Aparecido Corrêa; Greco, Camila Coelho; Denadai, Benedito Sérgio

    2014-01-01

    The purpose of this study was to determine both the independent and additive effects of prior heavy-intensity exercise and pacing strategies on the VO2 kinetics and performance during high-intensity exercise. Fourteen endurance cyclists (VO2max  = 62.8 ± 8.5 mL.kg-1.min-1) volunteered to participate in the present study with the following protocols: 1) incremental test to determine lactate threshold and VO2max; 2) four maximal constant-load tests to estimate critical power; 3) six bouts of exercise, using a fast-start (FS), even-start (ES) or slow-start (SS) pacing strategy, with and without a preceding heavy-intensity exercise session (i.e., 90% critical power). In all conditions, the subjects completed an all-out sprint during the final 60 s of the test as a measure of the performance. For the control condition, the mean response time was significantly shorter (p positive effects of priming exercise on the overall VO2 kinetics and short-term high-intensity performance.

  6. Comparison between whole-body vibration, light-emitting diode, and cycling warm-up on high-intensity physical performance during sprint bicycle exercise.

    Science.gov (United States)

    Teles, Maria C; Fonseca, Ivana A T; Martins, Jeanne B; de Carvalho, Marielle M; Xavier, Murilo; Costa, Sidney J; de Avelar, Núbia C P; Ribeiro, Vanessa G C; Salvador, Fabiano S; Augusto, Leonardo; Mendonça, Vanessa A; Lacerda, Ana C R

    2015-06-01

    The purpose of this study was to compare the effects of light-emitting diode (LED) irradiation and whole-body vibration (WBV) delivered either in isolation or combination (LED + WBV), warm-up (WU), and a control (C) treatment on performance during a sprint bicycle exercise. Ten cyclists performed a 30-second sprint cycle test under these conditions. The LED light was applied at 4 points bilaterally. Whole-body vibration consisted of 5 minutes of squats associated with WBV. LED + WBV consisted of WBV followed by LED therapy. Warm-up consisted of 17 minutes of moderate-intensity bicycle exercise. Control consisted of 10 minutes at rest. Blood lactate (BL) and ammonia (BA) levels and skin temperature (ST) were determined. Peak power (842 ± 117 vs. 800 ± 106 vs. 809 ± 128 W [p = 0.02 and p = 0.01]), relative power (12.1 ± 1.0 vs. 11.5 ± 0.9 vs. 11.6 ± 1.0 W·kg [p = 0.02 and p = 0.02]), and relative work (277 ± 23 vs. 263 ± 24 vs. 260 ± 23 J·kg [p = 0.02 and p = 0.003]) were higher in the WU group compared with the control and LED groups. In the LED + WBV group, peak (833 ± 115 vs. 800 ± 106 W [p = 0.02]) and relative (11.9 ± 0.9 vs. 11.5 ± 0.9 W·kg [p = 0.02]) power were higher than those in the control group, and relative work (272 ± 22 vs. 260 ± 23 J·kg [p = 0.02]) were improved compared with the LED group. There were no differences for BL, BA, and ST. The findings of this study confirmed the effectiveness of a warm-up as a preparatory activity and demonstrated that LED + WBV and WBV were as effective as WU in improving cyclist performance during a sprint bicycle exercise.

  7. High-intensity interval training evokes larger serum BDNF levels compared with intense continuous exercise.

    Science.gov (United States)

    Saucedo Marquez, Cinthia Maria; Vanaudenaerde, Bart; Troosters, Thierry; Wenderoth, Nicole

    2015-12-15

    Exercise can have a positive effect on the brain by activating brain-derived neurotrophic factor (BDNF)-related processes. In healthy humans there appears to be a linear relationship between exercise intensity and the positive short-term effect of acute exercise on BDNF levels (i.e., the highest BDNF levels are reported after high-intensity exercise protocols). Here we performed two experiments to test the effectiveness of two high-intensity exercise protocols, both known to improve cardiovascular health, to determine whether they have a similar efficacy in affecting BDNF levels. Participants performed a continuous exercise (CON) protocol at 70% of maximal work rate and a high-intensity interval-training (HIT) protocol at 90% of maximal work rate for periods of 1 min alternating with 1 min of rest (both protocols lasted 20 min). We observed similar BDNF kinetics in both protocols, with maximal BDNF concentrations being reached toward the end of training (experiment 1). We then showed that both exercise protocols significantly increase BDNF levels compared with a rest condition (CON P = 0.04; HIT P exercise are slightly more effective than continuous high-intensity exercise for elevating serum BDNF. Additionally, 73% of the participants preferred the HIT protocol (P = 0.02). Therefore, we suggest that the HIT protocol might represent an effective and preferred intervention for elevating BDNF levels and potentially promoting brain health.

  8. Low-intensity resistance training after high-intensity resistance training can prevent the increase of central arterial stiffness.

    Science.gov (United States)

    Okamoto, T; Masuhara, M; Ikuta, K

    2013-05-01

    Although high-intensity resistance training increases arterial stiffness, low-intensity resistance training reduces arterial stiffness. The present study investigates the effect of low-intensity resistance training before and after high-intensity resistance training on arterial stiffness. 30 young healthy subjects were randomly assigned to a group that performed low-intensity resistance training before high-intensity resistance training (BLRT, n=10), a group that performed low-intensity resistance training after high-intensity resistance training (ALRT, n=10) and a sedentary control group (n=10). The BLRT and ALRT groups performed resistance training at 80% and 50% of one repetition maximum twice each week for 10 wk. Arterial stiffness was measured using carotid-femoral and femoral-ankle pulse wave velocity (PWV). One-repetition maximum strength in the both ALRT and BLRT significantly increased after the intervention (Ptraining in the ALRT group did not change from before training. In contrast, carotid-femoral PWV after combined training in the BLRT group increased from before training (P training in the both BLRT and ALRT groups did not change from before training. These results suggest that although arterial stiffness is increased by low-intensity resistance training before high-intensity resistance training, performing low-intensity resistance training thereafter can prevent the increase of arterial stiffness. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Concept for a new high resolution high intensity diffractometer

    Energy Technology Data Exchange (ETDEWEB)

    Stuhr, U. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    A concept of a new time-of-flight powder-diffractometer for a thermal neutral beam tube at SINQ is presented. The design of the instrument optimises the contradictory conditions of high intensity and high resolution. The high intensity is achieved by using many neutron pulses simultaneously. By analysing the time-angle-pattern of the detected neutrons an assignment of the neutrons to a single pulse is possible. (author) 3 figs., tab., refs.

  10. Daily Oxygen/O3 Treatment Reduces Muscular Fatigue and Improves Cardiac Performance in Rats Subjected to Prolonged High Intensity Physical Exercise

    Directory of Open Access Journals (Sweden)

    C. Di Filippo

    2015-01-01

    Full Text Available Rats receiving daily intraperitoneal administration of O2 and running on a treadmill covered an average distance of 482.8 ± 21.8 m/week as calculated during 5-week observation. This distance was increased in rats receiving daily intraperitoneal administration of an oxygen/O3 mixture at a dose of 100; 150; and 300 μg/kg with the maximum increase being +34.5% at 300 μg/kg and still present after stopping the administration of oxygen/O3. Oxygen/O3 decreased the mean arterial blood pressure (−13%, the heart rate (−6%, the gastrocnemius and cardiac hypertrophy, and fibrosis and reduced by 49% the left ventricular mass and relative wall thickness measurements. Systolic and diastolic functions were improved in exercised oxygen/O3 rats compared to O2 rats. Oxygen/O3 treatment led to higher MPI index starting from the dose of 150 μg/kg (p<0.05 and more effective (+14% at a dose of 300 μg/kg oxygen/O3. Oxygen/O3 dose-dependently increased the expression of the antioxidant enzymes Mn-SOD and GPx1 and of eNOS compared to the exercised O2 rats. The same doses resulted in decrease of LDH levels, CPK, TnI, and nitrotyrosine concentration in the heart and gastrocnemius tissues, arguing a beneficial effect of the ozone molecule against the fatigue induced by a prolonged high intensity exercise.

  11. SALIVARY CORTISOL RESPONSES AND PERCEIVED EXERTION DURING HIGH INTENSITY AND LOW INTENSITY BOUTS OF RESISTANCE EXERCISE

    Directory of Open Access Journals (Sweden)

    Alison D. Egan

    2004-03-01

    Full Text Available The purpose of this study was to measure the salivary cortisol response to different intensities of resistance exercise. In addition, we wanted to determine the reliability of the session rating of perceived exertion (RPE scale to monitor resistance exercise intensity. Subjects (8 men, 9 women completed 2 trials of acute resistance training bouts in a counterbalanced design. The high intensity resistance exercise protocol consisted of six, ten-repetition sets using 75% of one repetition maximum (RM on a Smith machine squat and bench press exercise (12 sets total. The low intensity resistance exercise protocol consisted of three, ten-repetition sets at 30% of 1RM of the same exercises as the high intensity protocol. Both exercise bouts were performed with 2 minutes of rest between each exercise and sessions were repeated to test reliability of the measures. The order of the exercise bouts was randomized with least 72 hours between each session. Saliva samples were obtained immediately before, immediately after and 30 mins following each resistance exercise bout. RPE measures were obtained using Borg's CR-10 scale following each set. Also, the session RPE for the entire exercise session was obtained 30 minutes following completion of the session. There was a significant 97% increase in the level of salivary cortisol immediately following the high intensity exercise session (P<0.05. There was also a significant difference in salivary cortisol of 145% between the low intensity and high intensity exercise session immediately post-exercise (P<0.05. The low intensity exercise did not result in any significant changes in cortisol levels. There was also a significant difference between the session RPE values for the different intensity levels (high intensity 7.1 vs. low intensity 1.9 (P<0.05. The intraclass correlation coefficient for the session RPE measure was 0.95. It was concluded that the session RPE method is a valid and reliable method of

  12. Performance analysis of the ultra-linear optical intensity modulator

    Science.gov (United States)

    Madamopoulos, Nicholas; Dingel, Benjamin

    2006-10-01

    The linear optical intensity modulator is a key component in any broadband optical access-based analog fiber-optic link systems such as sub-carrier multiplexing (SCM) systems, ultra-dense CATV, Radio-over-Fiber (RoF) communications, and other platform access systems. Previously, we have proposed a super-linear optical modulator, having SFDR = 130 -140 dB-Hz 2/3, based on a unique combination of phase-modulator (PM) and a weak ring resonator (RR) modulator within a Mach-Zehnder interferometer (MZI). We presented some of its unique features. In this paper, we characterize further this ultra-linear optical intensity modulator, analyze its RF performance and provide method for parameter optimization. Other excellent features of this modulator design such as high manufacturing tolerance, effect of link insertion loss, adaptive characteristic and device simplicity are also discussed.

  13. The Effect of Financial Factors on the Performance of New Venture Companies in High Tech and Knowledge-Intensive Industries: An Empirical Study in Denmark

    DEFF Research Database (Denmark)

    Bøllingtoft, Anne; Ulhøi, John Parm; Madsen, Henning;

    2003-01-01

    This paper addresses important financial aspects during the formation of knowledge-intensive entrepreneurship. A number of ex ante derived hypotheses are submitted to an empirical test to identify and explain some of the key financial factors affecting the survival and first preliminary growth...

  14. The effect of four-week high-intensity interval training with beta-alanine supplementation on aerobic and anaerobic performance and some blood parameters in girls basketball players

    Directory of Open Access Journals (Sweden)

    bahareh ketabdar

    2017-06-01

    Full Text Available Background & Objective: The aim of the present study was to determine the effect of four-week high-intensity interval training with beta-alanine supplementation on aerobic and anaerobic performance and some blood parameters in girls basketball players. Materials & Methods: This was a quasi-experimental study. Twenty female basketball players, with the mean age of 24.65 ± 4.81 years, height of 166.97 ± 4.12 cm, weight of 59.15 ± 5.23 kg and body mass index of 21.5 ± 1.23 kg/m2, were divided into two groups, including intervention (exercise + supplement and control groups. Two days before and after the intervention, the subjects performed Wingate test (to estimate the average aerobic power and Bruce test (to estimate VO2max.The subjects attended basketball training two sessions per week; Intervention group performed high-intensity interval training in addition to the basketball training in every session. The dose of beta-alanine supplementation was 2.4, 3.6, 4.8 g per day. After four weeks, creatine kinase and lactate levels and performance tests were reevaluated. Data were analyzed by SPSS software version 21, with a significance level of P0.05. Conclusion: This study showed that high-intensity interval training with beta-alanine supplementation resulted in delay in the fatigue threshold, stabilization of PH and hydrogen ions balance, increased aerobic-anaerobic capacity and exercise performance in female basketball players.

  15. Acute plasma volume change with high-intensity sprint exercise.

    Science.gov (United States)

    Bloomer, Richard J; Farney, Tyler M

    2013-10-01

    When exercise is of long duration or of moderate to high intensity, a decrease in plasma volume can be observed. This has been noted for both aerobic and resistance exercise, but few data are available with regard to high-intensity sprint exercise. We measured plasma volume before and after 3 different bouts of acute exercise, of varying intensity, and/or duration. On different days, men (n = 12; 21-35 years) performed aerobic cycle exercise (60 minutes at 70% heart rate reserve) and 2 different bouts of cycle sprints (five 60-second sprints at 100% maximum wattage obtained during graded exercise testing (GXT) and ten 15-second sprints at 200% maximum wattage obtained during GXT). Blood was collected before and 0, 30, and 60 minutes postexercise and analyzed for hematocrit and hemoglobin and plasma volume was calculated. Plasma volume decreased significantly for all exercise bouts (p sprint bouts (∼19%) compared with aerobic exercise bouts (∼11%). By 30 minutes postexercise, plasma volume approached pre-exercise values. We conclude that acute bouts of exercise, in particular high-intensity sprint exercise, significantly decrease plasma volume during the immediate postexercise period. It is unknown what, if any negative implications these transient changes may have on exercise performance. Strength and conditioning professionals may aim to rehydrate athletes appropriately after high-intensity exercise bouts.

  16. High performance homes

    DEFF Research Database (Denmark)

    Beim, Anne; Vibæk, Kasper Sánchez

    2014-01-01

    Can prefabrication contribute to the development of high performance homes? To answer this question, this chapter defines high performance in more broadly inclusive terms, acknowledging the technical, architectural, social and economic conditions under which energy consumption and production occur....... Consideration of all these factors is a precondition for a truly integrated practice and as this chapter demonstrates, innovative project delivery methods founded on the manufacturing of prefabricated buildings contribute to the production of high performance homes that are cost effective to construct, energy...

  17. High performance homes

    DEFF Research Database (Denmark)

    Beim, Anne; Vibæk, Kasper Sánchez

    2014-01-01

    Can prefabrication contribute to the development of high performance homes? To answer this question, this chapter defines high performance in more broadly inclusive terms, acknowledging the technical, architectural, social and economic conditions under which energy consumption and production occur....... Consideration of all these factors is a precondition for a truly integrated practice and as this chapter demonstrates, innovative project delivery methods founded on the manufacturing of prefabricated buildings contribute to the production of high performance homes that are cost effective to construct, energy...

  18. Effects of 6-Weeks High-Intensity Interval Training in Schoolchildren with Insulin Resistance: Influence of Biological Maturation on Metabolic, Body Composition, Cardiovascular and Performance Non-responses

    Directory of Open Access Journals (Sweden)

    Cristian Alvarez

    2017-06-01

    Full Text Available Background: Previous studies have observed significant heterogeneity in the magnitude of change in measures of metabolic response to exercise training. There are a lack of studies examining the prevalence of non-responders (NRs in children while considering other potential environmental factors involved such as biological maturation.Aim: To compare the effects and prevalence of NRs to improve the insulin resistance level (by HOMA-IR, as well as to other anthropometric, cardiovascular, and performance co-variables, between early (EM and normal maturation (NM in insulin-resistance schoolchildren after 6-weeks of HIIT.Methods: Sedentary children (age 11.4 ± 1.7 years were randomized to either HIIT-EM group (n = 12 or HIIT-NM group (n = 17. Fasting glucose (FGL, fasting insulin (FINS and homeostasis model assessment of insulin resistant (HOMA-IR were assessed as the main outcomes, as well as the body composition [body mass, body mass index (BMI, waist circumference (WC, and tricipital (TSF, suprailiac (SSF and abdominal skinfold (AbdSF], cardiovascular systolic (SBP and diastolic blood pressure (DBP, and muscular performance [one-repetition maximum strength leg-extension (1RMLE and upper row (1RMUR tests] co-variables were assessed before and after intervention. Responders or NRs to training were defined as a change in the typical error method from baseline to follow-up for the main outcomes and co-variables.Results: There were no significant differences between groups in the prevalence of NRs based on FGL, FINS, and HOMA-IR. There were significant differences in NRs prevalence to decrease co-variables body mass (HIIT-EM 66.6% vs. HIIT-NM 35.2% and SBP (HIIT-EM 41.6% vs. HIIT-NM 70.5%. A high risk [based on odds ratios (OR] of NRs cases was detected for FGL, OR = 3.2 (0.2 to 5.6, and HOMA-IR, OR = 3.2 (0.2 to 6.0. Additionally, both HIIT-EM and HIIT-NM groups showed significant decreases (P < 0.05 in TSF, SSF, and AbdSF skinfold, and similar

  19. Effects of 6-Weeks High-Intensity Interval Training in Schoolchildren with Insulin Resistance: Influence of Biological Maturation on Metabolic, Body Composition, Cardiovascular and Performance Non-responses.

    Science.gov (United States)

    Alvarez, Cristian; Ramírez-Campillo, Rodrigo; Ramírez-Vélez, Robinson; Izquierdo, Mikel

    2017-01-01

    Background: Previous studies have observed significant heterogeneity in the magnitude of change in measures of metabolic response to exercise training. There are a lack of studies examining the prevalence of non-responders (NRs) in children while considering other potential environmental factors involved such as biological maturation. Aim: To compare the effects and prevalence of NRs to improve the insulin resistance level (by HOMA-IR), as well as to other anthropometric, cardiovascular, and performance co-variables, between early (EM) and normal maturation (NM) in insulin-resistance schoolchildren after 6-weeks of HIIT. Methods: Sedentary children (age 11.4 ± 1.7 years) were randomized to either HIIT-EM group (n = 12) or HIIT-NM group (n = 17). Fasting glucose (FGL), fasting insulin (FINS) and homeostasis model assessment of insulin resistant (HOMA-IR) were assessed as the main outcomes, as well as the body composition [body mass, body mass index (BMI), waist circumference (WC), and tricipital (TSF), suprailiac (SSF) and abdominal skinfold (AbdSF)], cardiovascular systolic (SBP) and diastolic blood pressure (DBP), and muscular performance [one-repetition maximum strength leg-extension (1RMLE) and upper row (1RMUR) tests] co-variables were assessed before and after intervention. Responders or NRs to training were defined as a change in the typical error method from baseline to follow-up for the main outcomes and co-variables. Results: There were no significant differences between groups in the prevalence of NRs based on FGL, FINS, and HOMA-IR. There were significant differences in NRs prevalence to decrease co-variables body mass (HIIT-EM 66.6% vs. HIIT-NM 35.2%) and SBP (HIIT-EM 41.6% vs. HIIT-NM 70.5%). A high risk [based on odds ratios (OR)] of NRs cases was detected for FGL, OR = 3.2 (0.2 to 5.6), and HOMA-IR, OR = 3.2 (0.2 to 6.0). Additionally, both HIIT-EM and HIIT-NM groups showed significant decreases (P < 0.05) in TSF, SSF, and AbdSF skinfold, and

  20. High Performance Marine Vessels

    CERN Document Server

    Yun, Liang

    2012-01-01

    High Performance Marine Vessels (HPMVs) range from the Fast Ferries to the latest high speed Navy Craft, including competition power boats and hydroplanes, hydrofoils, hovercraft, catamarans and other multi-hull craft. High Performance Marine Vessels covers the main concepts of HPMVs and discusses historical background, design features, services that have been successful and not so successful, and some sample data of the range of HPMVs to date. Included is a comparison of all HPMVs craft and the differences between them and descriptions of performance (hydrodynamics and aerodynamics). Readers will find a comprehensive overview of the design, development and building of HPMVs. In summary, this book: Focuses on technology at the aero-marine interface Covers the full range of high performance marine vessel concepts Explains the historical development of various HPMVs Discusses ferries, racing and pleasure craft, as well as utility and military missions High Performance Marine Vessels is an ideal book for student...

  1. High performance systems

    Energy Technology Data Exchange (ETDEWEB)

    Vigil, M.B. [comp.

    1995-03-01

    This document provides a written compilation of the presentations and viewgraphs from the 1994 Conference on High Speed Computing given at the High Speed Computing Conference, {open_quotes}High Performance Systems,{close_quotes} held at Gleneden Beach, Oregon, on April 18 through 21, 1994.

  2. The generation of high-quality, intense ion beams by ultra-intense lasers

    CERN Document Server

    Roth, M; Audebert, Patrick; Blazevic, A; Brambrink, E; Cowan, T E; Fuchs, J; Gauthier, J C; Geissel, M; Hegelich, M; Karsch, S; Meyer-Ter-Vehn, J; Ruhl, H; Schlegel, T; Stephens, R B

    2002-01-01

    Intense beams of protons and heavy ions have been observed in ultra-intense laser-solid interaction experiments. Thereby, a considerable fraction of the laser energy is transferred to collimated beams of energetic ions (e.g. up to 50 MeV protons; 100 MeV fluorine), which makes these beams highly interesting for various applications. Experimental results indicate a very short-pulse duration and an excellent beam quality, leading to beam intensities in the TW range. To characterize the beam quality and its dependence on laser parameters and target conditions we performed experiments using the 100 TW laser system at Laboratoire pour l'Utilisation des Lasers Intenses at the Ecole Polytechnique, France, with focused intensities exceeding 10 sup 1 sup 9 W cm sup - sup 2. We found a strong dependence on the target rear surface conditions allowing to tailor the ion beam by an appropriate target design. We also succeeded in the generation of heavy ion beams by suppressing the proton amount at the target surface. We wi...

  3. High-performance liquid chromatography coupled to direct analysis in real time mass spectrometry: investigations on gradient elution and influence of complex matrices on signal intensities.

    Science.gov (United States)

    Beissmann, Susanne; Buchberger, Wolfgang; Hertsens, Robert; Klampfl, Christian W

    2011-08-01

    Direct analysis in real time (DART) time-of-flight mass spectrometry (TOF-MS) has been tested for its suitability as a detector for gradient elution HPLC. Thereby a strong dependency of signal intensity on the amount of organic solvent present in the eluent could be observed. Adding a make-up liquid (iso-propanol) post-column to the HPLC effluent greatly enhanced detection limits for early eluting compounds. Limits of detection achieved employing this approach were in the range of 7-27 μg L(-1) for the parabene test mixture and 15-87 μg L(-1) for the pharmaceuticals. In further investigations DART ionization was compared to several other widely used atmospheric pressure ionization methods with respect to signal suppression phenomena occurring in when samples with problematic matrices are analyzed. For this purpose extracts from environmental and waste water samples were selected as model matrices which were subsequently spiked with a set of six substances commonly present in personal care products as well as six pharmaceuticals at concentration levels between 100 μg L(-1) and 500 μg L(-1) corresponding to 100 ng L(-1) and 500 ng L(-1) respectively in the original sample. With ionization suppression of less than 11% for most analytes investigated, DART ionization showed similar to even somewhat superior behavior compared to atmospheric pressure chemical ionization (APCI) and atmospheric pressure photo ionization (APPI) for the Danube river water extract; for the more challenging matrix of the sewage plant effluent extract DART provided better results with ion suppression being less than 11% for 9 out of 12 analytes while values for APCI were lying between 20% and >90%. Electrospray ionization (ESI) was much more affected by suppression effects than DART with values between 26% and 80% for Danube river water; in combination with the sewage plant effluent matrix suppression >50% was observed for all analytes.

  4. High-intensity intermittent swimming improves cardiovascular health status for women with mild hypertension

    DEFF Research Database (Denmark)

    Mohr, Magni; Nordsborg, Nikolai Baastrup; Lindenskov, Annika;

    2014-01-01

    To test the hypothesis that high-intensity swim training improves cardiovascular health status in sedentary premenopausal women with mild hypertension, sixty-two women were randomized into high-intensity (n = 21; HIT), moderate-intensity (n = 21; MOD), and control groups (n = 20; CON). HIT...... high-intensity intermittent swimming is an effective training strategy to improve cardiovascular health and physical performance...... in sedentary women with mild hypertension. Adaptations are similar with high- and moderate-intensity training, despite markedly less total time spent and distance covered in the high-intensity group....

  5. [Comparative analysis of application of highly intensive laser irradiation and electrocoagulation during laparoscopic cholecystectomy performed for destructive forms of an acute calculous cholecystitis].

    Science.gov (United States)

    Nichitayio, M Yu; Bazyak, A M; Klochan, V V; Grusha, P K; Goman, A V

    2015-02-01

    Comparative analysis of results of the laser diode (the wave length 940 nm) and elec- trocoagulation application while performing laparoscopic cholecystectomy was con- ducted. For an acute calculous cholecystitis 52 patients were operated, in whom instead of electrocoagulation the laser was applied, provide for reduction of thermal impact on tissues, the complications absence, reduction of the patients stationary treatment duration postoperatively from (5.2 ± 1.2) to (4.9 ± 0.6) days.

  6. Responsive design high performance

    CERN Document Server

    Els, Dewald

    2015-01-01

    This book is ideal for developers who have experience in developing websites or possess minor knowledge of how responsive websites work. No experience of high-level website development or performance tweaking is required.

  7. Seismic performance test and numerical simulation of prestressed high-intensity concrete pile%PHC管桩抗震性能试验及数值模拟

    Institute of Scientific and Technical Information of China (English)

    戎贤; 宋鹏; 李艳艳

    2014-01-01

    对3根PHC管桩进行了抗震性能拟静力试验,对其在低周往复荷载作用下的受力状态、破坏机理、恢复力特性进行了分析,得到了添加非预应力筋和剪切端勾型钢纤维对PHC管桩抗震性能的影响规律,并采用非线性有限元方法对PHC的受弯承载力进行了模拟分析。结果表明,配置一定数量非预应力筋可以改善管桩的抗震性能;而剪切端勾型钢纤维的加入则对其抗震性能影响不大,同时有限元所建立的计算模型是合理可行的,模拟结果与试验结果吻合较好。%Based on the experiment of three seismic performance PHC pile under low cyclic reversed lateral load,influence law about adding non-prestressed reinforcement and shear end hook steel fiber pile on seismic behavior was got according to the analy of stress state,failure mechanism,restoring force characteristics.The flexural strength of PHC are simulated and analyzed by nonlinear finite element method.The results show that a certain number of non-prestressed reinforcement configuration can improve the seismic performance of pile, adding cut end hook steel fiber while adding hook style steel fiber at the end of shear side has little effect on its seismic performance.The finite element calculation model established is reasonable and feasible.Calculation and analysis in good agreement with the experimental results was obtaind.

  8. Incremental effects of 28 days of beta-alanine supplementation on high-intensity cycling performance and blood lactate in masters female cyclists.

    Science.gov (United States)

    Glenn, J M; Gray, M; Stewart, R; Moyen, N E; Kavouras, S A; DiBrezzo, R; Turner, R; Baum, J

    2015-12-01

    Within the aging population, there exists a subset of individuals termed masters athletes (MA). As masters-level competition increases in popularity, MA must find methods to enhance individual athletic performance. Longitudinal beta-alanine (BA) supplementation is suggested to enhance physical capability during exercise; however, these effects have not been evaluated in MA. To examine the longitudinal effects of BA on time to exhaustion (TTE), total work completed (TWC), and lactate clearance in female MA cyclists. Twenty-two female MA (age = 53.3 ± 1.0) participated in this double-blind design. Subjects were randomly assigned to BA (n = 11; 800 mg BA + 8 g dextrose) or placebo (PLA; n = 11; 8 g dextrose) groups and supplemented 4 doses/day over 28 days. Every 7 days, subjects completed a cycling TTE at 120% VO2max, and TWC was calculated. Blood lactate was measured at baseline, immediate post, and 20-min post each TTE. No significant differences existed between groups for any variable at baseline (p > 0.05). After 28 days supplementation, BA had greater TTE (23 vs 1% change) and TWC (21 vs 2% change) than PLA (p < 0.05). Following the 20-min TTE recovery, lactate was 24% lower in BA compared to PLA (4.35 vs. 5.76 mmol/L, respectively). No differences existed for variables during intermittent weeks. 28 days of BA supplementation increased cycling performance via an enhanced time to exhaustion and total work completed with associated lactate clearance during passive rest in female MA.

  9. Growth performance, carcass yield and gait score of Marshal broiler chicken reared on intensive and semi intensive management systems

    Directory of Open Access Journals (Sweden)

    Oluwadiya, B. O.

    2017-06-01

    Full Text Available The rearing system used in highly productive farms is often subjected to harsh criticism, one of the reasons being its failure to provide adequate welfare. A number of attempts have been made to introduce new technologies in rearing poultry for meat production aiming at improving rearing conditions, protecting the environment and enhancing the quality of poultry products. Given the above, one hundred and sixty eight unsexed 14-day old Marshall broiler chicks were used in a completely randomized design study to compare the effect of management systems (intensive and semi intensive on the growth performance, carcass characteristics and gait score of broiler chickens. The experiment lasted for 42 d. Data were collected on weight gain, feed intake, feed conversion ratio, carcass yield and gait score. Result showed that birds on the intensive management system recorded higher weight gain (P 0.05; 66.94%, 11.44% than those in semi-intensive system (54.55%, 10.92%, respectively. For the gait score broiler birds on semi intensive management system recorded reduced number of cases of severe and slight leg problems (P < 0.05, 25.76% vs 49.3%. It was concluded that broiler birds should be reared on intensive management system for better growth performance and carcass yield. However, birds reared on semi intensive management system had fewer leg problems compared to birds reared on intensive management system. The fewer severe leg problems observed in birds on semi intensive management system will help improve their market value thereby making birds more profitable to rear on semi intensive management system.

  10. The effect of exercise intensity on cognitive performance during short duration treadmill running

    Directory of Open Access Journals (Sweden)

    Smith Mike

    2016-06-01

    Full Text Available This study examined the effect of short duration, moderate and high-intensity exercise on a Go/NoGo task. Fifteen, habitually active (9 females and 6 males aged 28 ± 5 years agreed to participate in the study and cognitive performance was measured in three sessions lasting 10 min each, performed at three different exercise intensities: rest, moderate and high. Results indicated significant exercise intensity main effects for reaction time (RT (p = 0.01, the omission error rate (p = 0.027 and the decision error rate (p = 0.011, with significantly longer RTs during high intensity exercise compared to moderate intensity exercise (p = 0.039 and rest (p = 0.023. Mean ± SE of RT (ms was 395.8 ± 9.1, 396.3 ± 9.1 and 433.5 ± 16.1 for rest, moderate and high intensity exercise, respectively. This pattern was replicated for the error rate with a significantly higher omission error and decision error rate during high intensity exercise compared to moderate intensity exercise (p = 0.003 and rest (p = 0.001. Mean ± SE of omission errors (% was 0.88 ± 0.23, 0.8 ± 0.23 and 1.8 ± 0.46% for rest, moderate and high intensity exercise, respectively. Likewise, mean ± SE of decision errors (% was 0.73 ± 0.24, 0.73 ± 0.21 and 1.8 ± 0.31 for rest, moderate and high intensity exercise, respectively. The present study’s results suggest that 10 min workout at high intensity impairs RT performances in habitually active adults compared to rest or moderate intensity exercise.

  11. The effect of exercise intensity on cognitive performance during short duration treadmill running

    Directory of Open Access Journals (Sweden)

    Smith Mike

    2016-06-01

    Full Text Available This study examined the effect of short duration, moderate and high-intensity exercise on a Go/NoGo task. Fifteen, habitually active (9 females and 6 males aged 28 ± 5 years agreed to participate in the study and cognitive performance was measured in three sessions lasting 10 min each, performed at three different exercise intensities: rest, moderate and high. Results indicated significant exercise intensity main effects for reaction time (RT (p = 0.01, the omission error rate (p = 0.027 and the decision error rate (p = 0.011, with significantly longer RTs during high intensity exercise compared to moderate intensity exercise (p = 0.039 and rest (p = 0.023. Mean ± SE of RT (ms was 395.8 ± 9.1, 396.3 ± 9.1 and 433.5 ± 16.1 for rest, moderate and high intensity exercise, respectively. This pattern was replicated for the error rate with a significantly higher omission error and decision error rate during high intensity exercise compared to moderate intensity exercise (p = 0.003 and rest (p = 0.001. Mean ± SE of omission errors (% was 0.88 ± 0.23, 0.8 ± 0.23 and 1.8 ± 0.46% for rest, moderate and high intensity exercise, respectively. Likewise, mean ± SE of decision errors (% was 0.73 ± 0.24, 0.73 ± 0.21 and 1.8 ± 0.31 for rest, moderate and high intensity exercise, respectively. The present study’s results suggest that 10 min workout at high intensity impairs RT performances in habitually active adults compared to rest or moderate intensity exercise.

  12. High-intensity sweeteners and energy balance.

    Science.gov (United States)

    Swithers, Susan E; Martin, Ashley A; Davidson, Terry L

    2010-04-26

    Recent epidemiological evidence points to a link between a variety of negative health outcomes (e.g. metabolic syndrome, diabetes and cardiovascular disease) and the consumption of both calorically sweetened beverages and beverages sweetened with high-intensity, non-caloric sweeteners. Research on the possibility that non-nutritive sweeteners promote food intake, body weight gain, and metabolic disorders has been hindered by the lack of a physiologically-relevant model that describes the mechanistic basis for these outcomes. We have suggested that based on Pavlovian conditioning principles, consumption of non-nutritive sweeteners could result in sweet tastes no longer serving as consistent predictors of nutritive postingestive consequences. This dissociation between the sweet taste cues and the caloric consequences could lead to a decrease in the ability of sweet tastes to evoke physiological responses that serve to regulate energy balance. Using a rodent model, we have found that intake of foods or fluids containing non-nutritive sweeteners was accompanied by increased food intake, body weight gain, accumulation of body fat, and weaker caloric compensation, compared to consumption of foods and fluids containing glucose. Our research also provided evidence consistent with the hypothesis that these effects of consuming saccharin may be associated with a decrement in the ability of sweet taste to evoke thermic responses, and perhaps other physiological, cephalic phase, reflexes that are thought to help maintain energy balance.

  13. Physics of intense, high energy radiation effects.

    Energy Technology Data Exchange (ETDEWEB)

    Hjalmarson, Harold Paul; Hartman, E. Frederick; Magyar, Rudolph J.; Crozier, Paul Stewart

    2011-02-01

    This document summarizes the work done in our three-year LDRD project titled 'Physics of Intense, High Energy Radiation Effects.' This LDRD is focused on electrical effects of ionizing radiation at high dose-rates. One major thrust throughout the project has been the radiation-induced conductivity (RIC) produced by the ionizing radiation. Another important consideration has been the electrical effect of dose-enhanced radiation. This transient effect can produce an electromagnetic pulse (EMP). The unifying theme of the project has been the dielectric function. This quantity contains much of the physics covered in this project. For example, the work on transient electrical effects in radiation-induced conductivity (RIC) has been a key focus for the work on the EMP effects. This physics in contained in the dielectric function, which can also be expressed as a conductivity. The transient defects created during a radiation event are also contained, in principle. The energy loss lead the hot electrons and holes is given by the stopping power of ionizing radiation. This information is given by the inverse dielectric function. Finally, the short time atomistic phenomena caused by ionizing radiation can also be considered to be contained within the dielectric function. During the LDRD, meetings about the work were held every week. These discussions involved theorists, experimentalists and engineers. These discussions branched out into the work done in other projects. For example, the work on EMP effects had influence on another project focused on such phenomena in gases. Furthermore, the physics of radiation detectors and radiation dosimeters was often discussed, and these discussions had impact on related projects. Some LDRD-related documents are now stored on a sharepoint site (https://sharepoint.sandia.gov/sites/LDRD-REMS/default.aspx). In the remainder of this document the work is described in catergories but there is much overlap between the atomistic

  14. High-Intensity, High Charge-State Heavy Ion Sources

    CERN Document Server

    Alessi, J

    2004-01-01

    There are many accelerator applications for high intensity heavy ion sources, with recent needs including dc beams for RIA, and pulsed beams for injection into synchrotrons such as RHIC and LHC. The present status of sources producing high currents of high charge state heavy ions will be reviewed. These sources include ECR, EBIS, and Laser ion sources. The benefits and limitations for these type sources will be described, for both dc and pulsed applications. Possible future improvements in these type sources will also be discussed.

  15. Clojure high performance programming

    CERN Document Server

    Kumar, Shantanu

    2013-01-01

    This is a short, practical guide that will teach you everything you need to know to start writing high performance Clojure code.This book is ideal for intermediate Clojure developers who are looking to get a good grip on how to achieve optimum performance. You should already have some experience with Clojure and it would help if you already know a little bit of Java. Knowledge of performance analysis and engineering is not required. For hands-on practice, you should have access to Clojure REPL with Leiningen.

  16. VO2 kinetics and performance in soccer players after intense training and inactivity

    DEFF Research Database (Denmark)

    Christensen, Peter Møller; Krustrup, Peter; Gunnarsson, Thomas P.;

    2011-01-01

    PURPOSE:: To examine the effects of a short-term period with intensified training or training cessation of trained soccer players on VO2 kinetics at 75% maximal aerobic speed (MAS), oxidative enzymes and performance in repeated high intensity exercise. METHODS:: After the last match of the season...... 18 elite soccer players were, for a two-week period, assigned to a high intensity training group (HI, n=7) performing 10 training sessions mainly consisting of aerobic high intensity training (8×2 min) and speed endurance training (10-12×30-s sprints) or a training cessation group (TC, n=11...

  17. High Performance Concrete

    OpenAIRE

    Traian Oneţ

    2009-01-01

    The paper presents the last studies and researches accomplished in Cluj-Napoca related to high performance concrete, high strength concrete and self compacting concrete. The purpose of this paper is to raid upon the advantages and inconveniences when a particular concrete type is used. Two concrete recipes are presented, namely for the concrete used in rigid pavement for roads and another one for self-compacting concrete.

  18. High Performance Concrete

    Directory of Open Access Journals (Sweden)

    Traian Oneţ

    2009-01-01

    Full Text Available The paper presents the last studies and researches accomplished in Cluj-Napoca related to high performance concrete, high strength concrete and self compacting concrete. The purpose of this paper is to raid upon the advantages and inconveniences when a particular concrete type is used. Two concrete recipes are presented, namely for the concrete used in rigid pavement for roads and another one for self-compacting concrete.

  19. Danish High Performance Concretes

    DEFF Research Database (Denmark)

    Nielsen, M. P.; Christoffersen, J.; Frederiksen, J.

    1994-01-01

    In this paper the main results obtained in the research program High Performance Concretes in the 90's are presented. This program was financed by the Danish government and was carried out in cooperation between The Technical University of Denmark, several private companies, and Aalborg University...

  20. High Intensity Beam Issues in the CERN Proton Synchrotron

    CERN Document Server

    Aumon, Sandra; Rivkin, Leonid

    This PhD work is about limitations of high intensity proton beams observed in the CERN Proton Synchrotron (PS) and, in particular, about issues at injection and transition energies. With its 53 years, the CERN PS would have to operate beyond the limit of its performance to match the future requirements. Beam instabilities driven by transverse impedance and aperture restrictions are important issues for the operation and for the High-Luminosity LHC upgrade which foresees an intensity increase delivered by the injectors. The main subject of the thesis concerns the study of a fast transverse instability occurring at transition energy. The proton beams crossing this energy range are particularly sensitive to wake forces because of the slow synchrotron motion. This instability can cause a strong vertical emittance blow-up and severe losses in less than a synchrotron period. Experimental observations show that the particles at the peak density of the beam longitudinal distribution oscillate in the vertical plane du...

  1. Effects of intensity and duration in aerobic high-intensity interval training in highly trained junior cross-country skiers.

    Science.gov (United States)

    Sandbakk, Øyvind; Sandbakk, Silvana B; Ettema, Gertjan; Welde, Boye

    2013-07-01

    The purpose of this study was to test whether a long duration of aerobic high-intensity interval training is more effective than shorter intervals at a higher intensity in highly trained endurance athletes. The sample comprised of 12 male and 9 female, national-level, junior cross-country skiers (age, 17.5 ± 0.4 years, maximal oxygen uptake (V[Combining Dot Above]O2max): 67.4 ± 7.7 ml min kg), who performed 8-week baseline and 8-week intervention training periods on dry land. During the intervention period, a short-interval group (SIG, n = 7) added 2 weekly sessions with short duration intervals (2- to 4-minute bouts, total duration of 15-20 minutes), a long-interval group (LIG; n = 7) added 2 weekly sessions with long duration intervals (5- to 10-minute bouts, total duration of 40-45 minutes). The interval sessions were performed with the athletes' maximal sustainable intensity. A control group (CG; n = 7) added 2 weekly sessions with low-intensity endurance training at 65-74% of maximal heart rate. Before and after the intervention period, the skiers were tested for time-trial performance on 12-km roller-ski skating and 7-km hill run. V[Combining Dot Above]O2max and oxygen uptake at the ventilatory threshold (V[Combining Dot Above]O2VT) were measured during treadmill running. After the intervention training period, the LIG-improved 12-km roller ski, 7-km hill run, V[Combining Dot Above]O2max, and V[Combining Dot Above]O2VT by 6.8 ± 4.0%, 4.8 ± 2.6%, 3.7 ± 1.6%, and 5.8 ± 3.3%, respectively, from pre- to posttesting, and improved both performance tests and V[Combining Dot Above]O2VT when compared with the SIG and the CG (all p < 0.05). The SIG improved V[Combining Dot Above]O2max by 3.5 ± 3.2% from pre- to posttesting (p < 0.05), whereas the CG remained unchanged. As hypothesized, a long duration of aerobic high-intensity interval training improved endurance performance and oxygen uptake at the ventilatory threshold more than shorter intervals at a higher

  2. High performance AC drives

    CERN Document Server

    Ahmad, Mukhtar

    2010-01-01

    This book presents a comprehensive view of high performance ac drives. It may be considered as both a text book for graduate students and as an up-to-date monograph. It may also be used by R & D professionals involved in the improvement of performance of drives in the industries. The book will also be beneficial to the researchers pursuing work on multiphase drives as well as sensorless and direct torque control of electric drives since up-to date references in these topics are provided. It will also provide few examples of modeling, analysis and control of electric drives using MATLAB/SIMULIN

  3. Relationship between performance at different exercise intensities and skeletal muscle characteristics

    DEFF Research Database (Denmark)

    Iaia, F Marcello; Perez-Gomez, Jorge; Thomassen, Martin

    2011-01-01

    The hypothesis investigated whether exercise performance over a broad range of intensities is determined by specific skeletal muscle characteristics. Seven subjects performed 8-10 exhaustive cycle trials at different work loads ranging from 150 to 700 W (150 min - 20 s). No relationships between...... the performance times at high and low work loads were observed. A relationship (P...

  4. Ergogenic effects of caffeine and sodium bicarbonate supplementation on intermittent exercise performance preceded by intense arm cranking exercise

    OpenAIRE

    Marriott, Matthaus; Krustrup, Peter; Mohr, Magni

    2015-01-01

    BACKGROUND: Caffeine and sodium bicarbonate ingestion have been suggested to improve high-intensity intermittent exercise, but it is unclear if these ergogenic substances affect performance under provoked metabolic acidification. To study the effects of caffeine and sodium bicarbonate on intense intermittent exercise performance and metabolic markers under exercise-induced acidification, intense arm-cranking exercise was performed prior to intense intermittent running after intake of placebo,...

  5. EFSA NDA Panel (EFSA Panel on Dietetic Products, Nutrition and Allergies), 2014. Scientific Opinion on the substantiation of a health claim related to beta-alanine and increase in physical performance during short-duration, high-intensity exercise pursuant to Article 13(5) of Regulation (EC

    DEFF Research Database (Denmark)

    Tetens, Inge

    on the scientific substantiation of a health claim related to beta-alanine and increase in physical performance during short-duration, high-intensity exercise. The food constituent that is the subject of the claim is beta-alanine, which is sufficiently characterised. The Panel considers that an increase in physical...... performance during short-duration, high-intensity exercise is a beneficial physiological effect. In weighing the evidence the Panel took into account that only one out of 11 pertinent human intervention studies (including 14 pertinent outcomes) from which conclusions could be drawn showed an effect of beta-alanine...... on physical performance during short-duration, high intensity exercise. The Panel concludes that a cause and effect relationship has not been established between the consumption of beta-alanine and an increase in physical performance during short-duration, high intensity exercise....

  6. LIQUID ARGON CALORIMETER PERFORMANCE AT HIGH RATES

    CERN Document Server

    Kukhtin, V; The ATLAS collaboration

    2011-01-01

    The performance of the ATLAS liquid argon endcap and forward calorimeters has been projected at the planned high luminosity LHC option HL-LHC by exposing small calorimeter modules of the electromagnetic, hadronic, and forward calorimeters to high intensity proton beams at IHEP/Protvino accelerator. The results of HV current and of pulse shape analysis, and also the dependence of signal amplitude on beam intensity are presented.

  7. FNAL Proton Source High Intensity Operations and Beam Loss Control

    CERN Document Server

    Garcia, F G

    2014-01-01

    The 40-year-old Fermilab Proton Source machines, constituted by the Pre-Injector, Linac and the synchrotron Booster, have been the workhorse of the Fermi National Accelerator Laboratory (Fermilab). During this time, the High Energy Physics Program has demanded an increase in proton throughput, especially during the past decade with the beginning of the neutrino program at Fermilab. In order to achieve a successful program, major upgrades and changes were made in Booster. Once again, the Proton Source has been charged to double their beam throughput, while maintain the present residual activation levels, to meet the laboratory Intensity Frontier program goals until new machines are built and operational to replace the Proton Source machines. This paper discusses the present performance of Booster and the plans involved in reaching even higher intensities.

  8. Short-pulse high intensity laser thin foil interaction

    Science.gov (United States)

    Audebert, Patrick

    2003-10-01

    The technology of ultrashort pulse laser generation has progressed to the point that optical pulses larger than 10 J, 300 fs duration or shorter are routinely produced. Such pulses can be focused to intensities exceeding 10^18 W/cm^2. With high contrast pulses, these focused intensities can be used to heat solid matter to high temperatures with minimal hydrodynamic expansion, producing an extremely high energy-density state of matter for a short period of time. This high density, high temperature plasma can be studied by x-ray spectroscopy. We have performed experiments on thin foils of different elements under well controlled conditions at the 100 Terawatt laser at LULI to study the characteristics X-ray emission of laser heated solids. To suppress the ASE effect, the laser was frequency doubled. S-polarized light with a peak intensity of 10^19W/cm^2 was used to minimize resonance absorption. To decrease the effect of longitudinal temperature gradients very thin (800 μ) aluminum foil targets were used. We have also studied the effect of radial gradient by limiting the measured x-ray emission zone using 50μ or 100μ pinhole on target. The spectra, in the range 7-8Å, were recorded using a conical crystal spectrometer coupled to a 800 fs resolution streak camera. A Fourier Domain Interferometry (FDI) of the back of the foil was also performed providing a measurement of the hydrodynamic expansion as function of time for each shot. To simulate the experiment, we used the 1D hydrodynamic code FILM with a given set of plasma parameter (ρ, Te) as initial conditions. The X-ray emission was calculated by post processing hydrodynamic results with a collisional-radiative model which uses super-configuration average atomic data. The simulation reproduces the main features of the experimental time resolved spectrum.

  9. High Performance Liquid Chromatography

    Science.gov (United States)

    Talcott, Stephen

    High performance liquid chromatography (HPLC) has many applications in food chemistry. Food components that have been analyzed with HPLC include organic acids, vitamins, amino acids, sugars, nitrosamines, certain pesticides, metabolites, fatty acids, aflatoxins, pigments, and certain food additives. Unlike gas chromatography, it is not necessary for the compound being analyzed to be volatile. It is necessary, however, for the compounds to have some solubility in the mobile phase. It is important that the solubilized samples for injection be free from all particulate matter, so centrifugation and filtration are common procedures. Also, solid-phase extraction is used commonly in sample preparation to remove interfering compounds from the sample matrix prior to HPLC analysis.

  10. Electron cloud instability in high intensity proton rings

    Directory of Open Access Journals (Sweden)

    K. Ohmi

    2002-11-01

    Full Text Available An e^{-}p instability has been observed in some proton rings. The instability, which causes beam loss, limits the performance of the ring. The instability may be serious for 3 and 50 GeV proton storage rings in the Japan Proton Accelerator Research Complex (J-PARC. We study the e^{-}p instability in several high intensity proton storage rings operated in the world. This work informs J-PARC of the necessity to cure the instability, for example, by applying a TiN coating on the chamber surface.

  11. High Performance RAIT

    Institute of Scientific and Technical Information of China (English)

    JamesHughes; CharlesMilligan; 等

    2001-01-01

    The ability to move 10s of TeraBytes in reasonable amounts of time are critical to many of the High Energy Physics applications.This paper examines the issues of high performance,high reliability tape storage systems,and presents the results of a 2-year ASCI Path Forward program to be able to reliably move 1GB/s to an archive that can last 20 years.This paper will cover the requirements.approach,hardware,application software,interface descriptions,performance,measured reliability and predicted reliability.This paper will also touch on future directions for this research.The current research allows systems to sustain 80MB/s of uncompressable data per Fibre Channel interface which is striped out to 8 or more drives.This looks to the application as a single tape drive from both mout and data transfer perspectives .Striping 12 RAIT systems together will provide nearly 1GB/s to tape.The reliability is provided by a method of adding parity tapes to the data stripes.For example,adding 2 parity tapes to an 8-stripe group will allow any 2 of the 10 tapes to be lost or damaged without loss of information.The reliability of RAIT with 8 stripes and 2 parities exceeds that of mirrored tapes while RAIT uses 10 tapes instead of the 16 tapes that a mirror would require.The results of this paper is to be abloe to understand the applicability of RAIT and to be able to understand when it may be useful in High Energy Physics applications.

  12. High-intensity positron microprobe at Jefferson Lab

    CERN Document Server

    Golge, Serkan; Wojtsekhowski, Bogdan

    2014-01-01

    We present a conceptual design for a novel continuous wave electron-linac based high-intensity slow-positron production source with a projected intensity on the order of 10$^{10}$ e$^+$/s. Reaching this intensity in our design relies on the transport of positrons (T$_+$ below 600 keV) from the electron-positron pair production converter target to a low-radiation and low-temperature area for moderation in a high-efficiency cryogenic rare gas moderator, solid Ne. The performance of the integrated beamline has been verified through computational studies. The computational results include Monte Carlo calculations of the optimized electron/positron beam energies, converter target thickness, synchronized raster system, transport of the beam from the converter target to the moderator, extraction of the beam from the channel, and moderation efficiency calculations. For the extraction of positrons from the magnetic channel a magnetic field terminator plug prototype has been built and experimental data on the effective...

  13. Intensity ratio measurements for density sensitive lines of highly charged Fe ions

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Safdar, E-mail: safdaruetian@gmail.com; Shimizu, Erina [Institute for Laser Science, The University of Electro-Communications (Japan); Sakaue, Hiroyuki A.; Kato, Daiji; Murakami, Izumi [National Institute for Fusion Science (Japan); Yamamoto, Norimasa [Chubu University (Japan); Hara, Hirohisa; Watanabe, Tetsuya [The Graduate University of Advanced Studies (SOKENDAI) (Japan); Nakamura, Nobuyuki, E-mail: n-nakamu@ils.uec.ac.jp [Institute for Laser Science, The University of Electro-Communications (Japan)

    2015-11-15

    Intensity ratio of density sensitive emission lines emitted from Fe ions in the extreme ultraviolet region is important for astrophysics applications. We report high-resolution intensity ratio measurements for Fe ions performed at Tokyo EBIT laboratory by employing a flat-field grazing incidence spectrometer. The experimental intensity ratios of Fe X and Fe XII are plotted as a function of electron density for different electron beam currents. The experimental results are compared with the predicted intensity ratios from the model calculations.

  14. Is high-intensity exercise better than moderate-intensity exercise for weight loss?

    Science.gov (United States)

    De Feo, P

    2013-11-01

    This viewpoint debates the state-of-the-art research focusing on the optimal intensity of the exercise programs for inducing a sustained weight or fat-mass loss in overweight/obese people. In our demanding society, the most attractive messages in the popular press are those promising the best results in a short time. This might explain the emphasis given by media to those scientific articles that report the efficacy on weight loss of exercise programs by their shorter duration and higher intensity. However, in the literature on overweight or obese people, there is little conclusive evidence for more favorable effects with high-intensity training than with continuous moderate-intensity exercise on body weight or fat mass loss. Since both exercise protocols have been demonstrated as useful to reduce body weight, the decision on the intensity of exercise prescription should be individualized and based on outcomes different from fat or weight loss. In this regard, there are pro and contra arguments for the prescription of high-intensity aerobic exercise in obese people. Among the pro arguments, is the demonstration that, in several studies, high-intensity training appears to induce superior improvements in aerobic fitness. Among the contra arguments to prescribe high-intensity exercise is the demonstration that prescribing a higher-intensity exercise decreases adherence and results in the completion of less exercise. Thus, a successful exercise program should be proposed at a moderate intensity and a low perceived effort because obese subjects who have low self-efficacy, poor mood status, and are not familiar with high-intensity workouts could easily drop out. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. High performance work practices, innovation and performance

    DEFF Research Database (Denmark)

    Jørgensen, Frances; Newton, Cameron; Johnston, Kim

    2013-01-01

    Research spanning nearly 20 years has provided considerable empirical evidence for relationships between High Performance Work Practices (HPWPs) and various measures of performance including increased productivity, improved customer service, and reduced turnover. What stands out from...

  16. Muscle fatigue during high-intensity exercise in children.

    Science.gov (United States)

    Ratel, Sébastien; Duché, Pascale; Williams, Craig A

    2006-01-01

    Children are able to resist fatigue better than adults during one or several repeated high-intensity exercise bouts. This finding has been reported by measuring mechanical force or power output profiles during sustained isometric maximal contractions or repeated bouts of high-intensity dynamic exercises. The ability of children to better maintain performance during repeated high-intensity exercise bouts could be related to their lower level of fatigue during exercise and/or faster recovery following exercise. This may be explained by muscle characteristics of children, which are quantitatively and qualitatively different to those of adults. Children have less muscle mass than adults and hence, generate lower absolute power during high-intensity exercise. Some researchers also showed that children were equipped better for oxidative than glycolytic pathways during exercise, which would lead to a lower accumulation of muscle by-products. Furthermore, some reports indicated that the lower ability of children to activate their type II muscle fibres would also explain their greater resistance to fatigue during sustained maximal contractions. The lower accumulation of muscle by-products observed in children may be suggestive of a reduced metabolic signal, which induces lower ratings of perceived exertion. Factors such as faster phosphocreatine resynthesis, greater oxidative capacity, better acid-base regulation, faster readjustment of initial cardiorespiratory parameters and higher removal of metabolic by-products in children could also explain their faster recovery following high-intensity exercise.From a clinical point of view, muscle fatigue profiles are different between healthy children and children with muscle and metabolic diseases. Studies of dystrophic muscles in children indicated contradictory findings of changes in contractile properties and the muscle fatigability. Some have found that the muscle of boys with Duchenne muscular dystrophy (DMD) fatigued less

  17. Crystalline silicon cell performance at low light intensities

    Energy Technology Data Exchange (ETDEWEB)

    Reich, N.H.; van Sark, W.G.J.H.M.; Alsema, E.A.; Turkenburg, W.C. [Utrecht University, Faculty of Science, Copernicus Institute for Sustainable Development and Innovation, Department of Science, Techonology and Society, Heidelberglaan 2, 3584 CS Utrecht (Netherlands); Lof, R.W.; Schropp, R.E.I. [Utrecht University, Faculty of Science, Debye Institute for Nanomaterials Science, Nanophotonics - Physics of Device, Utrecht University, P.O. Box 80.000, 3508 TA Utrecht (Netherlands); Sinke, W.C. [Energy research Centre of the Netherlands (ECN), P.O. Box 1, 1755 ZG Petten (Netherlands)

    2009-09-15

    Measured and modelled JV characteristics of crystalline silicon cells below one sun intensity have been investigated. First, the JV characteristics were measured between 3 and 1000 W/m{sup 2} at 6 light levels for 41 industrially produced mono- and multi-crystalline cells from 8 manufacturers, and at 29 intensity levels for a single multi-crystalline silicon between 0.01 and 1000 W/m{sup 2}. Based on this experimental data, the accuracy of the following four modelling approaches was evaluated: (1) empirical fill factor expressions, (2) a purely empirical function, (3) the one-diode model and (4) the two-diode model. Results show that the fill factor expressions and the empirical function fail at low light intensities, but a new empirical equation that gives accurate fits could be derived. The accuracy of both diode models are very high. However, the accuracy depends considerably on the used diode model parameter sets. While comparing different methods to determine diode model parameter sets, the two-diode model is found to be preferred in principle: particularly its capability in accurately modelling V{sub OC} and efficiency with one and the same parameter set makes the two-diode model superior. The simulated energy yields of the 41 commercial cells as a function of irradiance intensity suggest unbiased shunt resistances larger than about 10 k{omega} cm{sup 2} may help to avoid low energy yields of cells used under predominantly low light intensities. Such cells with diode currents not larger than about 10{sup -9} A/cm{sup 2} are excellent candidates for Product Integrated PV (PIPV) appliances. (author)

  18. The influence of basketball dribbling on repeated high-intensity intermittent runs

    Directory of Open Access Journals (Sweden)

    Zhaowei Kong

    2015-12-01

    Conclusion: The results suggest that the Yo-Yo IE2 test could reflect the repeatability of high-intensity intermittent basketball dribbling performance, while dribbling skills may have different influences on high-intensity intermittent exercise capacity in adolescent players at different ages.

  19. High Performance Work Systems and Firm Performance.

    Science.gov (United States)

    Kling, Jeffrey

    1995-01-01

    A review of 17 studies of high-performance work systems concludes that benefits of employee involvement, skill training, and other high-performance work practices tend to be greater when new methods are adopted as part of a consistent whole. (Author)

  20. The different effects of high intensity interval training and moderate intensity interval training for weightlessness countermeasures

    Science.gov (United States)

    Wang, Lin-Jie; Cheng, Tan; Zhi-Li, Li; Hui-juan, Wang; Wen-juan, Chen; Jianfeng, Zhang; Desheng, Wang; Dongbin, Niu; Qi, Zhao; Chengjia, Yang; Yanqing, Wang

    High intensity interval training (HIIT) has been demonstrated to improve performance in a relatively short training period. But the difference between high intensity interval training and moderate intensity interval training (MIIT) in simulated weightlessness still has not been well studied. This study sought to characterize the difference between 6 weeks high intensity interval training and moderate intensity interval training under reduced weight (RW) gait training device and zero-gravity locomotion system (ZLS). Twenty-three subjects (14M/4F, 32.5±4.5 years) volunteered to participate. They were divided into three groups, that were MITT (alternating 2 min at 40% VO _{2} peak and 2 min at 60% VO _{2} peak for 30min, five days per week) RW group (n=8), HITT (alternating 2 min at 40% VO _{2} peak and 2 min at 90% VO _{2} peak for 30min, three days per week) RW group (n=8) and HITT ZLS group (n=7). The Z-axis load used in RW group was 80% body weight (BW) and in ZLS was 100% BW. Cardiopulmonary function was measured before, after 4-week training and after 6-week training. Isokinetic knee extension-flexion test at 60(°) deg/s and 180(°) deg/s were performed before and after the 6-week training, and isometric knee extension-flexion test at 180(°) deg/s was also examined at the same time. It was found that the VO _{2} peaks, metabolic equivalent (MET), Speedmax and respiratory exchange ratio (RER) were significantly increased after 4 and 6-week training in all three groups and no significant group difference were detected. The peak torque at 60(°) deg/s for right knee flexion were significantly increased after 6 week-training in all three groups, and only in HITT RW group the total power at 60(°) deg/s for right knee flexion enhanced. The total power and average power at 60(°) deg/s for right knee extension decreased significantly after 6-week training in all three groups. The peak torque at 60(°) deg/s for right knee extension in MIIT RW group was

  1. R high performance programming

    CERN Document Server

    Lim, Aloysius

    2015-01-01

    This book is for programmers and developers who want to improve the performance of their R programs by making them run faster with large data sets or who are trying to solve a pesky performance problem.

  2. Increased collection efficiency of LIFI high intensity electrodeless light source

    Science.gov (United States)

    Hafidi, Abdeslam; DeVincentis, Marc; Duelli, Markus; Gilliard, Richard

    2008-02-01

    Recently, RF driven electrodeless high intensity light sources have been implemented successfully in the projection display systems for HDTV and videowall applications. This paper presents advances made in the RF waveguide and electric field concentrator structures with the purpose of reducing effective arc size and increasing light collection. In addition, new optical designs are described that further improve system efficiency. The results of this work demonstrate that projection system light throughput is increased relative to previous implementations and performance is optimized for home theater and other front projector applications that maintain multi-year lifetime without re-lamping, complete spectral range, fast start times and high levels of dynamic contrast due to dimming flexibility in the light source system.

  3. Endurance, aerobic high-intensity, and repeated sprint cycling performance is unaffected by normobaric "Live High-Train Low": a double-blind placebo-controlled cross-over study.

    Science.gov (United States)

    Bejder, Jacob; Andersen, Andreas Breenfeldt; Buchardt, Rie; Larsson, Tanja Hultengren; Olsen, Niels Vidiendal; Nordsborg, Nikolai Baastrup

    2017-05-01

    The aim was to investigate whether 6 weeks of normobaric "Live High-Train Low" (LHTL) using altitude tents affect highly trained athletes incremental peak power, 26-km time-trial cycling performance, 3-min all-out performance, and 30-s repeated sprint ability. In a double-blinded, placebo-controlled cross-over design, seven highly trained triathletes were exposed to 6 weeks of normobaric hypoxia (LHTL) and normoxia (placebo) for 8 h/day. LHTL exposure consisted of 2 weeks at 2500 m, 2 weeks at 3000 m, and 2 weeks at 3500 m. Power output during an incremental test, ~26-km time trial, 3-min all-out exercise, and 8 × 30 s of all-out sprint was evaluated before and after the intervention. Following at least 8 weeks of wash-out, the subjects crossed over and repeated the procedure. Incremental peak power output was similar after both interventions [LHTL: 375 ± 74 vs. 369 ± 70 W (pre-vs-post), placebo: 385 ± 60 vs. 364 ± 79 W (pre-vs-post)]. Likewise, mean power output was similar between treatments as well as before and after each intervention for time trial [LHTL: 257 ± 49 vs. 254 ± 54 W (pre-vs-post), placebo: 267 ± 57 vs. 267 ± 52 W (pre-vs-post)], and 3-min all-out [LHTL: 366 ± 68 vs. 369 ± 72 W (pre-vs-post), placebo: 365 ± 66 vs. 355 ± 71 W (pre-vs-post)]. Furthermore, peak- and mean power output during repeated sprint exercise was similar between groups at all time points (n = 5). In conclusion, 6 weeks of normobaric LHTL using altitude tents simulating altitudes of 2500-3500 m conducted in a double-blinded, placebo-controlled cross-over design do not affect power output during an incremental test, a ~26-km time-trial test, or 3-min all-out exercise in highly trained triathletes. Furthermore, 30 s of repeated sprint ability was unaltered.

  4. High-Intensity Interval Training Elicits Higher Enjoyment than Moderate Intensity Continuous Exercise.

    Science.gov (United States)

    Thum, Jacob S; Parsons, Gregory; Whittle, Taylor; Astorino, Todd A

    2017-01-01

    Exercise adherence is affected by factors including perceptions of enjoyment, time availability, and intrinsic motivation. Approximately 50% of individuals withdraw from an exercise program within the first 6 mo of initiation, citing lack of time as a main influence. Time efficient exercise such as high intensity interval training (HIIT) may provide an alternative to moderate intensity continuous exercise (MICT) to elicit substantial health benefits. This study examined differences in enjoyment, affect, and perceived exertion between MICT and HIIT. Twelve recreationally active men and women (age = 29.5 ± 10.7 yr, VO2max = 41.4 ± 4.1 mL/kg/min, BMI = 23.1 ± 2.1 kg/m2) initially performed a VO2max test on a cycle ergometer to determine appropriate workloads for subsequent exercise bouts. Each subject returned for two additional exercise trials, performing either HIIT (eight 1 min bouts of cycling at 85% maximal workload (Wmax) with 1 min of active recovery between bouts) or MICT (20 min of cycling at 45% Wmax) in randomized order. During exercise, rating of perceived exertion (RPE), affect, and blood lactate concentration (BLa) were measured. Additionally, the Physical Activity Enjoyment Scale (PACES) was completed after exercise. Results showed higher enjoyment (p = 0.013) in response to HIIT (103.8 ± 9.4) versus MICT (84.2 ± 19.1). Eleven of 12 participants (92%) preferred HIIT to MICT. However, affect was lower (pHIIT versus MICT. Although HIIT is more physically demanding than MICT, individuals report greater enjoyment due to its time efficiency and constantly changing stimulus.

  5. Effect of preseason concurrent muscular strength and high-intensity interval training in professional soccer players.

    Science.gov (United States)

    Wong, Pui-lam; Chaouachi, Anis; Chamari, Karim; Dellal, Alexandre; Wisloff, Ulrik

    2010-03-01

    This study examined the effect of concurrent muscular strength and high-intensity running interval training on professional soccer players' explosive performances and aerobic endurance. Thirty-nine players participated in the study, where both the experimental group (EG, n = 20) and control group (CG, n = 19) participated in 8 weeks of regular soccer training, with the EG receiving additional muscular strength and high-intensity interval training twice per week throughout. Muscular strength training consisted of 4 sets of 6RM (repetition maximum) of high-pull, jump squat, bench press, back half squat, and chin-up exercises. The high-intensity interval training consisted of 16 intervals each of 15-second sprints at 120% of individual maximal aerobic speed interspersed with 15 seconds of rest. EG significantly increased (p aerobic speed test, and maximal aerobic speed. High-intensity interval running can be concurrently performed with high load muscular strength training to enhance soccer players' explosive performances and aerobic endurance.

  6. Performance and noise analysis of optical microresonator-based biochemical sensors using intensity detection.

    Science.gov (United States)

    Zhou, Xiaoyan; Zhang, Lin; Pang, Wei

    2016-08-01

    Optical microcavity sensors using intensity detection open up the possibility to realize fully integrated high-performance sensing devices, which are significant for both fundamental study of molecular interaction and rapid disease diagnosis. Although the performance of microresonator-based sensors has been studied focusing on the resonance-tracking method, the situation can be much different for intensity-detection sensors. Here we conducted a systematically investigation on the noises sources in intensity detection scheme and their influences on key performance parameters, e.g., signal-to-noise ratio (SNR), limit-of-detection (LOD), and detection range, for various sensors configurations. Especially, the trade-off between SNR and LOD is identified and theoretically analyzed. With experiment noises taken into consideration, our work aims to provide design guidelines for integrated microresonator sensors with optimized performance.

  7. High Intensity Accelerator and Neutron Source in China

    Science.gov (United States)

    Guan, Xialing; Wei, J.; Loong, Chun

    2011-06-01

    High intensity Accelerator is being studied all over world for numerous applications, which includes the waste transmutation, spallation neutron source and material irradiation facilities. The R/D activities of the technology of High intensity accelerator are also developed in China for some year, and have some good facilities around China. This paper will reports the status of some high intensity accelerators and neutron source in China, which including ADS/RFQ; CARR; CSNS; PKUNIFTY & CPHS. This paper will emphatically report the Compact Pulsed Hadron Source (CPHS) led by the Department of Engineering Physics of Tsinghua University in Beijing, China.

  8. ELECTRON CLOUD EFFECTS IN HIGH INTENSITY PROTON ACCELERATORS.

    Energy Technology Data Exchange (ETDEWEB)

    WEI,J.; MACEK,R.J.

    2002-04-14

    One of the primary concerns in the design and operation of high-intensity proton synchrotrons and accumulators is the electron cloud and associated beam loss and instabilities. Electron-cloud effects are observed at high-intensity proton machines like the Los Alamos National Laboratory's PSR and CERN's SPS, and investigated experimentally and theoretically. In the design of next-generation high-intensity proton accelerators like the Spallation Neutron Source ring, emphasis is made in minimizing electron production and in enhancing Landau damping. This paper reviews the present understanding of the electron-cloud effects and presents mitigation measures.

  9. High-intensity intermittent swimming improves cardiovascular health status for women with mild hypertension

    DEFF Research Database (Denmark)

    Mohr, Magni; Nordsborg, Nikolai Baastrup; Lindenskov, Annika;

    2014-01-01

    To test the hypothesis that high-intensity swim training improves cardiovascular health status in sedentary premenopausal women with mild hypertension, sixty-two women were randomized into high-intensity (n = 21; HIT), moderate-intensity (n = 21; MOD), and control groups (n = 20; CON). HIT...... performed 6-10 × 30 s all-out swimming interspersed by 2 min recovery and MOD swam continuously for 1 h at moderate intensity for a 15-week period completing in total 44 ± 1 and 43 ± 1 sessions, respectively. In CON, all measured variables were similar before and after the intervention period. Systolic BP...... swim (13 ± 3% and 22 ± 3%), interval swimming (23 ± 3% and 8 ± 3%), and Yo-Yo IE1 running performance (58 ± 5% and 45 ± 4%). In conclusion, high-intensity intermittent swimming is an effective training strategy to improve cardiovascular health and physical performance...

  10. R & D Intensity and Firm Performance of High-tech Enterprises---Incentive Contract Design Based on Accounting and Market Performance Contrast%高新技术企业R & D投入强度与企业业绩--基于会计和市场业绩对比的激励契约设计

    Institute of Scientific and Technical Information of China (English)

    吴卫华; 万迪窻; 吴祖光

    2014-01-01

    This paper takes the panel data of high-tech companies listed in Chinese Growth Enterprise Market from 2009 to 2012 as samples,and uses accounting and market performance measures to study the relationship between high-tech companies’performance and R&D intensity.The result shows that there is an inverted U-shaped relationship between high-tech companies’performance and R&D intensity.Further researches also show that:(1 )R&D intensity which a-chieves the highest market performance is higher than the accounting one;(2)compared with the decreasing performance proceed,the sensitivity of performance to R&D intensity when the performance is increasing is higher;(3)the sensitivity of accounting performance to R&D intensity is lower than the market performance.Therefore,the companies have to weigh the R&D intensity level according to expecting its performance,and the incentives based on market performance are more con-ducive for enterprises to increase R&D investment and improve the efficiency of R&D activities.%以2009~2012年中国创业板高新技术上市公司的面板数据作为样本,使用会计和市场业绩计量指标,研究了高新技术企业业绩与R&D投入之间的关系。结果表明高新技术企业业绩与其R&D投入强度之间存在倒U型关系,随着R&D投入强度的增加,公司业绩先逐渐上升而后逐步下降。进一步的研究还发现:(1)实现最高市场业绩时的R&D投入强度要高于会计业绩最高时的R&D投入强度;(2)与业绩下降时相比,上升阶段业绩对R&D投入强度的敏感性更高;(3)市场业绩对R&D投入强度的敏感性高于会计业绩对R&D投入强度的敏感性。因此,企业需根据其要实现的会计或市场业绩权衡R&D投入强度。基于市场业绩的激励政策更有利于企业加大R&D投入,提高研发投资活动效率。

  11. Repeated high-intensity exercise in professional rugby union.

    Science.gov (United States)

    Austin, Damien; Gabbett, Tim; Jenkins, David

    2011-07-01

    The aim of the present study was to describe the frequency, duration, and nature of repeated high-intensity exercise in Super 14 rugby union. Time-motion analysis was used during seven competition matches over the 2008 and 2009 Super 14 seasons; five players from each of four positional groups (front row forwards, back row forwards, inside backs, and outside backs) were assessed (20 players in total). A repeated high-intensity exercise bout was considered to involve three or more sprints, and/or tackles and/or scrum/ruck/maul activities within 21 s during the same passage of play. The range of repeated high-intensity exercise bouts for each group in a match was as follows: 11-18 for front row forwards, 11-21 for back row forwards, 13-18 for inside backs, and 2-11 for outside backs. The durations of the most intense repeated high-intensity exercise bouts for each position ranged from 53 s to 165 s and the minimum recovery periods between repeated high-intensity exercise bouts ranged from 25 s for the back row forwards to 64 s for the front row forwards. The present results show that repeated high-intensity exercise bouts vary in duration and activities relative to position but all players in a game will average at least 10 changes in activity in the most demanding bouts and complete at least one tackle and two sprints. The most intense periods of activity are likely to last as long as 120 s and as little as 25 s recovery may separate consecutive repeated high-intensity exercise bouts. The present findings can be used by coaches to prepare their players for the most demanding passages of play likely to be experienced in elite rugby union.

  12. Optical Fiber High Temperature Sensor Instrumentation for Energy Intensive Industries

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, Kristie L.; Wang, Anbo; Pickrell, Gary R.

    2006-11-14

    This report summarizes technical progress during the program “Optical Fiber High Temperature Sensor Instrumentation for Energy Intensive Industries”, performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The objective of this program was to use technology recently invented at Virginia Tech to develop and demonstrate the application of self-calibrating optical fiber temperature and pressure sensors to several key energy-intensive industries where conventional, commercially available sensors exhibit greatly abbreviated lifetimes due primarily to environmental degradation. A number of significant technologies were developed under this program, including • a laser bonded silica high temperature fiber sensor with a high temperature capability up to 700°C and a frequency response up to 150 kHz, • the world’s smallest fiber Fabry-Perot high temperature pressure sensor (125 x 20 μm) with 700°C capability, • UV-induced intrinsic Fabry-Perot interferometric sensors for distributed measurement, • a single crystal sapphire fiber-based sensor with a temperature capability up to 1600°C. These technologies have been well demonstrated and laboratory tested. Our work plan included conducting major field tests of these technologies at EPRI, Corning, Pratt & Whitney, and Global Energy; field validation of the technology is critical to ensuring its usefulness to U.S. industries. Unfortunately, due to budget cuts, DOE was unable to follow through with its funding commitment to support Energy Efficiency Science Initiative projects and this final phase was eliminated.

  13. The high intensity solar cell: Key to low cost photovoltaic power

    Science.gov (United States)

    Sater, B. L.; Goradia, C.

    1975-01-01

    The design considerations and performance characteristics of the 'high intensity' (HI) solar cell are presented. A high intensity solar system was analyzed to determine its cost effectiveness and to assess the benefits of further improving HI cell efficiency. It is shown that residential sized systems can be produced at less than $1000/kW peak electric power. Due to their superior high intensity performance characteristics compared to the conventional and VMJ cells, HI cells and light concentrators may be the key to low cost photovoltaic power.

  14. High Performance Computing Today

    Energy Technology Data Exchange (ETDEWEB)

    Dongarra, Jack; Meuer,Hans; Simon,Horst D.; Strohmaier,Erich

    2000-04-01

    In last 50 years, the field of scientific computing has seen a rapid change of vendors, architectures, technologies and the usage of systems. Despite all these changes the evolution of performance on a large scale however seems to be a very steady and continuous process. Moore's Law is often cited in this context. If the authors plot the peak performance of various computers of the last 5 decades in Figure 1 that could have been called the supercomputers of their time they indeed see how well this law holds for almost the complete lifespan of modern computing. On average they see an increase in performance of two magnitudes of order every decade.

  15. Investigations on transport and storage of high ion beam intensities

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Ninad Shrikrishna

    2009-08-25

    In the framework of this thesis the intense low energy ion beam transport was investigated. Especially, the beam transport in toroidal magnetic field configurations was discussed, as it may allow the accumulation of high intensive beams in the future. One of the specific tasks is to design an injection system that can be used for the proposed low energy accumulator ring. A simulation code (TBT) was written to describe the particle motion in curved segments. Particle in Cell techniques were utilized to simulate a multi particle dynamics. A possibility of reading an external data file was made available so that a measured distribution can be used to compare simulation results with measured ones. A second order cloud in cell method was used to calculate charge density and in turn to solve Poisson's equation. Further simulations were performed to study the self field effects on beam transport. Experiments were performed to compare the simulation results and gain practical experience. The preparatory experiments consisted of building and characterization of the ion source in a first step. Along with the momentum spectrometer and emittance scanner the beam properties were studied. Low mass ion beams He{sup +} and mixed p, H{sup 2+}, H{sup 3+} beams were analyzed. In the second stage, beams were transported through a solenoid and the phase space distribution was measured as a function of the magnetic field for different beam energies. The phase-space as distributions measured in a first stage were simulated backward and then again forward transported through the solenoid. The simulated results were then compared with the measured distribution. The LINTRA transport program was used. The phase-space distribution was further simulated for transport experiments in a toroidal magnetic field. The transport program that was used to simulate the beam in the toroid was also used to design the injection system. The injection system with its special field configurations was

  16. Python high performance programming

    CERN Document Server

    Lanaro, Gabriele

    2013-01-01

    An exciting, easy-to-follow guide illustrating the techniques to boost the performance of Python code, and their applications with plenty of hands-on examples.If you are a programmer who likes the power and simplicity of Python and would like to use this language for performance-critical applications, this book is ideal for you. All that is required is a basic knowledge of the Python programming language. The book will cover basic and advanced topics so will be great for you whether you are a new or a seasoned Python developer.

  17. High Intensity Tactical Power Sources for the 1990 Army.

    Science.gov (United States)

    conceptual or physical study which may become feasible as high intensity power sources . These considerations include present state of the art of...requirements, energy and power output capabilities, and fixed costs. From these tables, it may be seen that a variety of electrical power sources would be...required to satisfy diverse requirements, but an attempt is made to categorize possible high intensity power sources into their areas of optimum

  18. NGINX high performance

    CERN Document Server

    Sharma, Rahul

    2015-01-01

    System administrators, developers, and engineers looking for ways to achieve maximum performance from NGINX will find this book beneficial. If you are looking for solutions such as how to handle more users from the same system or load your website pages faster, then this is the book for you.

  19. High performance germanium MOSFETs

    Energy Technology Data Exchange (ETDEWEB)

    Saraswat, Krishna [Department of Electrical Engineering, Stanford University, Stanford, CA 94305 (United States)]. E-mail: saraswat@stanford.edu; Chui, Chi On [Department of Electrical Engineering, Stanford University, Stanford, CA 94305 (United States); Krishnamohan, Tejas [Department of Electrical Engineering, Stanford University, Stanford, CA 94305 (United States); Kim, Donghyun [Department of Electrical Engineering, Stanford University, Stanford, CA 94305 (United States); Nayfeh, Ammar [Department of Electrical Engineering, Stanford University, Stanford, CA 94305 (United States); Pethe, Abhijit [Department of Electrical Engineering, Stanford University, Stanford, CA 94305 (United States)

    2006-12-15

    Ge is a very promising material as future channel materials for nanoscale MOSFETs due to its high mobility and thus a higher source injection velocity, which translates into higher drive current and smaller gate delay. However, for Ge to become main-stream, surface passivation and heterogeneous integration of crystalline Ge layers on Si must be achieved. We have demonstrated growth of fully relaxed smooth single crystal Ge layers on Si using a novel multi-step growth and hydrogen anneal process without any graded buffer SiGe layer. Surface passivation of Ge has been achieved with its native oxynitride (GeO {sub x}N {sub y} ) and high-permittivity (high-k) metal oxides of Al, Zr and Hf. High mobility MOSFETs have been demonstrated in bulk Ge with high-k gate dielectrics and metal gates. However, due to their smaller bandgap and higher dielectric constant, most high mobility materials suffer from large band-to-band tunneling (BTBT) leakage currents and worse short channel effects. We present novel, Si and Ge based heterostructure MOSFETs, which can significantly reduce the BTBT leakage currents while retaining high channel mobility, making them suitable for scaling into the sub-15 nm regime. Through full band Monte-Carlo, Poisson-Schrodinger and detailed BTBT simulations we show a dramatic reduction in BTBT and excellent electrostatic control of the channel, while maintaining very high drive currents in these highly scaled heterostructure DGFETs. Heterostructure MOSFETs with varying strained-Ge or SiGe thickness, Si cap thickness and Ge percentage were fabricated on bulk Si and SOI substrates. The ultra-thin ({approx}2 nm) strained-Ge channel heterostructure MOSFETs exhibited >4x mobility enhancements over bulk Si devices and >10x BTBT reduction over surface channel strained SiGe devices.

  20. High Intensity Interval Training in Handcycling : The Effects of a 7 Week Training Intervention in Able-bodied Men

    NARCIS (Netherlands)

    Schoenmakers, Patrick; Reed, Kate; Van Der Woude, Luc; Hettinga, Florentina J.

    2016-01-01

    INTRODUCTION: In lower body endurance training, quantities of both moderate intensity continuous training (MICT) and high intensity interval training (HIIT) can lead to an improved physiological capacity and performance. Limited research is available regarding the endurance and muscular capacity of

  1. Effect of high intensity ultrasound on the allergenicity of shrimp

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The tropomyosin fraction of shrimp proteins is potentially responsible for allergic reaction in individuals with genetic predisposition to allergy. However, there are no efficient and safe methods to reduce its allergenicity. High intensity ultrasound is known to change the structure of proteins. This study is aimed at assessing high intensity ultrasound's effect on the allergenicity of shrimp allergen. Shrimp and purified shrimp allergen were treated with high intensity ultrasound for 30~180 min. Extracts of treated samples were analyzed by enzyme-linked immunosorbent assay (ELISA) with pool serum of shrimp allergy patients and polyclonal anti-allergen antibodies and by immunoblotting after polyacrylamide gel electrophoresis. Shrimp treated with high intensity ultrasound showed a decrease in allergenicity measured with ELISA. A linear relationship between the immune response induced by treated shrimp allergen and the applied treatment time was observed. The decrease in allergenicity was confirmed by immunoblot assays with shrimp allergic patients serum. Allergenicity of shrimp allergen extracted from treated shrimp was higher than that of purified shrimp allergen with the same treatment time. Gel-filtration HPLC was applied for analysis of shrimp allergen after treatment with high intensity ultrasound. Some fractions were appeared with increasing treatment time. The results suggested that high intensity ultrasound could be used to reduce the allergenicity of shrimp.

  2. High performance collectors

    Science.gov (United States)

    Ogawa, H.; Hozumi, S.; Mitsumata, T.; Yoshino, K.; Aso, S.; Ebisu, K.

    1983-04-01

    Materials and structures used for flat plate solar collectors and evacuated tubular collectors were examined relative to their overall performance to project effectiveness for building heating and cooling and the feasibility of use for generating industrial process heat. Thermal efficiencies were calculated for black paint single glazed, selective surface single glazed, and selective surface double glazed flat plate collectors. The efficiencies of a single tube and central tube accompanied by two side tube collectors were also studied. Techniques for extending the lifetimes of the collectors were defined. The selective surface collectors proved to have a performance superior to other collectors in terms of the average annual energy delivered. Addition of a black chrome-coated fin system to the evacuated collectors produced significant collection efficiency increases.

  3. New Zealand Blackcurrant Extract Improves High-Intensity Intermittent Running.

    Science.gov (United States)

    Perkins, Ian Craig; Vine, Sarah Anne; Blacker, Sam David; Willems, Mark Elisabeth Theodorus

    2015-10-01

    We examined the effect of New Zealand blackcurrant (NZBC) extract on high-intensity intermittent running and postrunning lactate responses. Thirteen active males (age: 25 ± 4 yrs, height: 1.82 ± 0.07 m, body mass: 81 ± 14 kg, VO2max: 56 ± 4 ml·kg-1·min-1, vVO2max: 17.6 ± 0.8 km·h-1) performed a treadmill running protocol to exhaustion, which consisted of stages with 6 × 19 s of sprints with 15 s of low-intensity running between sprints. Interstage rest time was 1 min and stages were repeated with increasing sprint speeds. Subjects consumed capsuled NZBC extract (300 mg·day-1 CurraNZ; containing 105 mg anthocyanin) or placebo for 7 days (double-blind, randomized, crossover design, wash-out at least 14 days). Blood lactate was collected for 30 min postexhaustion. NZBC increased total running distance by 10.6% (NZBC: 4282 ± 833 m, placebo: 3871 ± 622 m, p = .02), with the distance during sprints increased by 10.8% (p = .02). Heart rate, oxygen uptake, lactate and rating of perceived exertion were not different between conditions for the first 4 stages completed by all subjects. At exhaustion, blood lactate tended to be higher for NZBC (NZBC: 6.01 ± 1.07 mmol·L-1, placebo: 5.22 ± 1.52 mmol·L-1, p = .07). There was a trend for larger changes in lactate following 15 min (NZBC: -2.89 ± 0.51 mmol·L-1, placebo: -2.46 ± 0.39 mmol·L-1, p = .07) of passive recovery. New Zealand blackcurrant extract (CurraNZ) may enhance performance in sports characterized by high-intensity intermittent exercise as greater distances were covered with repeated sprints, there was higher lactate at exhaustion, and larger changes in lactate during early recovery after repeated sprints to exhaustion.

  4. High Performance Magnets

    Science.gov (United States)

    2000-03-29

    Our efforts in this project were focused on three different materials, namely; interstitial Sm-Fe carbides and nitrides, high energy product Nd2Fe14B ...magnets with MgO addition, and nanocomposite Nd2Fe14B /alpha-Fe consisting of a fine mixture of hard and soft phases. In the Sm-Fe carbides and

  5. High Performance Biocomputation

    Science.gov (United States)

    2005-03-01

    ab initio calculation of a small protein has been reported (1PNH, a scorpion toxin with 31 residues and 500 atoms; [3]). Hybrid classical and first...challenge can be characterized as highly computationally-savvy and fully capable of effectively exploiting state-of-the-art capability. However, there...enilarrassingly parallel comlrltations, where little or no comnmiinication is required), capacity computing is an effective approac-h. A recent extension of

  6. High performance steam development

    Energy Technology Data Exchange (ETDEWEB)

    Duffy, T.; Schneider, P. [Solar Turbines Inc., San Diego, CA (United States)

    1995-10-01

    Over 30 years ago U.S. industry introduced the world`s highest temperature (1200{degrees}F at 5000 psig) and most efficient power plant, the Eddystone coal-burning steam plant. The highest alloy material used in the plant was 316 stainless steel. Problems during the first few years of operation caused a reduction in operating temperature to 1100{degrees}F which has generally become the highest temperature used in plants around the world. Leadership in high temperature steam has moved to Japan and Europe over the last 30 years.

  7. High performance polymer concrete

    Directory of Open Access Journals (Sweden)

    Frías, M.

    2007-06-01

    Full Text Available This paper studies the performance of concrete whose chief components are natural aggregate and an organic binder —a thermosetting polyester resin— denominated polymer concrete or PC. The material was examined macro- and microscopically and its basic physical and mechanical properties were determined using mercury porosimetry, scanning electron microscopy (SEM-EDAX, X-ray diffraction (XRD and strength tests (modulus of elasticity, stress-strain curves and ultimate strengths. According to the results of these experimental studies, the PC exhibited a low density (4.8%, closed pore system and a concomitantly continuous internal microstructure. This would at least partially explain its mechanical out-performance of traditional concrete, with average compressive and flexural strength values of 100 MPa and over 20 MPa, respectively. In the absence of standard criteria, the bending test was found to be a useful supplement to compressive strength tests for establishing PC strength classes.Este trabajo de investigación aborda el estudio de un hormigón de altas prestaciones, formado por áridos naturales y un aglomerante orgánico constituido por una resina termoestable poliéster, denominado hormigón polimérico HP. Se describe el material a nivel microscópico y macroscópico, presentando sus propiedades físicas y mecánicas fundamentales, mediante diferentes técnicas experimentales, tales como: porosimetría de mercurio, microscopía electrónica (SEM-EDAX, difracción de rayos X (DRX y ensayos mecánicos (módulo de elasticidad, curvas tensión- deformación y resistencias últimas. Como consecuencia del estudio experimental llevado a cabo, se ha podido apreciar cómo el HP está formado por porosidad cerrada del 4,8%, proporcionando una elevada continuidad a su microestructura interna, lo que justifica, en parte, la mejora de propiedades mecánicas respecto al hormigón tradicional, con unos valores medios de resistencia a compresión de 100

  8. Resistance training and detraining effects on flexibility performance in the elderly are intensity-dependent.

    Science.gov (United States)

    Fatouros, Ioannis G; Kambas, Antonios; Katrabasas, Ioannis; Leontsini, Diamanda; Chatzinikolaou, Athanasios; Jamurtas, Athanasios Z; Douroudos, Ioannis; Aggelousis, Nikolaos; Taxildaris, Kiriakos

    2006-08-01

    The present investigation attempted to determine whether resistance exercise intensity affects flexibility and strength performance in the elderly following a 6-month resistance training and detraining period. Fifty-eight healthy, inactive older men (65- 78 yrs) were randomly assigned to 1 of 4 groups: a control group (C, n = 10), a low-intensity resistance training group (LI, n = 14, 40% of 1 repetition maximum [1RM]), a moderate-intensity resistance training group (MI, n = 12, 60% of 1RM), or a high-intensity resistance training group (HI, n = 14, 80% of 1RM). Subjects in exercise groups followed a 3 days per week, whole-body (10 exercises, 3 sets per exercise) protocol for 24 weeks. Training was immediately followed by a 24-week detraining period. Strength (bench and leg press 1RM) and range of motion in trunk, elbow, knee, shoulder, and hip joints were measured at baseline and during training and detraining. Resistance training increased upper- (34% in LI, 48% in MI, and 75% in HI) and lower-body strength (38% in LI, 53% in MI, and 63% in HI) in an intensity-dependent manner. Flexibility demonstrated an intensity-dependent enhancement (3-12% in LI, 6-22% in MI, and 8-28% in HI). Detraining caused significant losses in strength (70-98% in LI, 44-50% in MI, and 27-29% in HI) and flexibility (90-110% in LI, 30-71% in MI, and 23-51% in HI) in an intensity-dependent manner. Results indicate that resistance training by itself improves flexibility in the aged. However, intensities greater than 60% of 1RM are more effective in producing flexibility gains, and strength improvement with resistance training is also intensity-dependent. Detraining seems to reverse training strength and flexibility gains in the elderly in an intensity-dependent manner.

  9. Review of High-intensity Interval Training in Cardiac Rehabilitation.

    Science.gov (United States)

    Ito, Shigenori; Mizoguchi, Tatsuya; Saeki, Tomoaki

    2016-01-01

    For the secondary prevention of cardiovascular disease, comprehensive cardiac rehabilitation is required. This involves optimal medical therapy, education on nutrition and exercise therapy, and smoking cessation. Of these, efficient exercise therapy is a key factor. A highly effective training protocol is therefore warranted, which requires a high rate of compliance. Although moderate-intensity continuous training has been the main training regimen recommended in cardiac rehabilitation guidelines, high-intensity interval training has been reported to be more effective in the clinical and experimental setting from the standpoint of peak oxygen uptake and central and peripheral adaptations. In this review, we illustrate the scientific evidence for high-intensity interval training. We then verify this evidence and discuss its significance and the remaining issues.

  10. Benefits of High-Intensity Intensive Care Unit Physician Staffing under the Affordable Care Act

    Directory of Open Access Journals (Sweden)

    Sachin Logani

    2011-01-01

    Full Text Available The Affordable Care Act signed into law by President Obama, with its value-based purchasing program, is designed to link payment to quality processes and outcomes. Treatment of critically ill patients represents nearly 1% of the gross domestic product and 25% of a typical hospital budget. Data suggest that high-intensity staffing patterns in the intensive care unit (ICU are associated with cost savings and improved outcomes. We evaluate the literature investigating the cost-effectiveness and clinical outcomes of high-intensity ICU physician staffing as recommended by The Leapfrog Group (a consortium of companies that purchase health care for their employees and identify ways to overcome barriers to nationwide implementation of these standards. Hospitals that have implemented the Leapfrog initiative have demonstrated reductions in mortality and length of stay and increased cost savings. High-intensity staffing models appear to be an immediate cost-effective way for hospitals to meet the challenges of health care reform.

  11. High-intensity light-emitting diode vs fluorescent tubes for intensive phototherapy in neonates.

    Science.gov (United States)

    Sherbiny, Hanan S; Youssef, Doaa M; Sherbini, Ahmad S; El-Behedy, Rabab; Sherief, Laila M

    2016-05-01

    Special blue fluorescent tubes are recommended by the American Academy of Pediatrics (AAP) as the most effective light source for lowering serum bilirubin. A high-intensity light-emitting diode ('super LED') could render intensive phototherapy more effective than the above conventional methods. This study compared the efficacy and safety of a high-intensity light-emitting diode bed vs conventional intensive phototherapy with triple fluorescent tube units as a rescue treatment for severe unconjugated neonatal hyperbilirubinaemia. This was a randomised, prospective trial. Two hundred jaundiced neonates ≥ 35 weeks gestation who met the criteria for intensive phototherapy as per AAP guidelines were randomly assigned to be treated either with triple fluorescent tube units (group 1, n = 100) or a super LED bed (group 2, n = 100). The outcome was the avoidance of exchange transfusion by successful control of hyperbilirubinaemia. Statistically significant higher success rates of intensive phototherapy were achieved among neonates treated with super LED (group 2) than in those treated conventionally (group 1) (87% vs 64%, P = 0.003). Significantly higher 'bilirubin decline' rates were reported in both haemolytic and non-haemolytic subgroups treated with the super LED bed compared with a similar sub-population in the conventionally treated group. Comparable numbers of neonates in both groups developed rebound jaundice (8% vs 10% of groups 1 and 2, respectively). Side-effects were mild in both groups, but higher rates of hyperthermia (12% vs 0%, P = 0.03), dehydration (8% vs 2%, P = 0.26) and skin rash (39% vs 1%, P = 0.002) were reported in the fluorescent tubes-treated group compared with the LED group. Super LED is a safe rescue treatment for severe neonatal hyperbilirubinaemia, and its implementation may reduce the need for exchange transfusion.

  12. Simulation study of the high intensity S-Band photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Xiongwei; Nakajima, Kazuhisa [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan)

    2001-10-01

    In this paper, we report the results of simulation study of the high intensity S-Band photoinjector. The aim of the simulation study is to transport high bunch charge with low emittance evolution. The simulation result shows that 7nC bunch with rms emittance 22.3 {pi} mm mrad can be outputted at the exit of photoinjector. (author)

  13. Generation of Intense High-Order Vortex Harmonics

    CERN Document Server

    Zhang, Xiaomei; Shi, Yin; Wang, Xiaofeng; Zhang, Lingang; Wang, Wenpeng; Xu, Jiancai; Yi, Longqiong; Xu, Zhizhan

    2014-01-01

    This paper presents the method for the first time to generate intense high-order optical vortices that carry orbital angular momentum in the extreme ultraviolet region. In three-dimensional particle-in-cell simulation, both the reflected and transmitted light beams include high-order harmonics of the Laguerre-Gaussian (LG) mode when a linearly polarized LG laser pulse impinges on a solid foil. The mode of the generated LG harmonic scales with its order, in good agreement with our theoretical analysis. The intensity of the generated high-order vortex harmonics is close to the relativistic region, and the pulse duration can be in attosecond scale. The obtained intense vortex beam possesses the combined properties of fine transversal structure due to the high-order mode and the fine longitudinal structure due to the short wavelength of the high-order harmonics. Thus, the obtained intense vortex beam may have extraordinarily promising applications for high-capacity quantum information and for high-resolution dete...

  14. High Intensity Particle Physics at PW-class laser facilities

    Science.gov (United States)

    Bulanov, Stepan; Schroeder, Carl; Esarey, Eric; Esirkepov, Timur; Kando, Masaki; Rosanov, Nikolay; Korn, Georg; Bulanov, Sergey V.; Leemans, Wim P.

    2015-11-01

    The processes typical for high intensity particle physics, i.e., the interactions of charged particles with strong electromagnetic fields, have attracted considerable interest recently. Some of these processes, previously believed to be of theoretical interest only, are now becoming experimentally accessible. High intensity electromagnetic (EM) fields significantly modify the interactions of particles and EM fields, giving rise to the phenomena that are not encountered either in classical or perturbative quantum theory of these interactions. One of such phenomena is the radiation reaction, which radically influences the electron motion in an electromagnetic standing wave formed by two super-intense counter-propagating laser pulses. Depending on the laser intensity and wavelength, either classical or quantum mode of radiation reaction prevail, or both are strong. When radiation reaction dominates, electron motion evolves to limit cycles and strange attractors. This creates a new framework for high energy physics experiments on an interaction of energetic charged particle beams and colliding super-intense laser pulses. Work supported by U.S. DOE under Contract No. DE-AC02-05CH11231.

  15. Effect of high-intensity training on endothelial function in patients with cardiovascular and cerebrovascular disease

    DEFF Research Database (Denmark)

    Kolmos, Mia; Krawcyk, Rikke Steen; Kruuse, Christina

    2016-01-01

    OBJECTIVES: Exercise improves endothelial dysfunction, the key manifestation of cardiovascular and cerebrovascular disease, and is recommended in both cardiovascular and cerebrovascular rehabilitation. Disagreement remains, however, on the role of intensity of exercise. The purpose of this review...... was to gather current knowledge on the effects of high-intensity training versus moderate-intensity continuous exercise on endothelial function in cardiovascular and cerebrovascular patients. METHODS: A systematic review was performed in PubMed database, Embase and Cochrane libraries and on PEDro using...... the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Studies were restricted to cardiovascular and cerebrovascular patients, and healthy subjects as general reference. Interventions comprised of high-intensity training alone, high-intensity training compared to moderate...

  16. High Performance Space Pump Project

    Data.gov (United States)

    National Aeronautics and Space Administration — PDT is proposing a High Performance Space Pump based upon an innovative design using several technologies. The design will use a two-stage impeller, high temperature...

  17. The Effects of Maximal Intensity Exercise on Cognitive Performance in Children

    Directory of Open Access Journals (Sweden)

    Samuel Roy David

    2017-06-01

    Full Text Available High intensity physical exercise has previously been found to lead to a decline in cognitive performance of adults. The aim of this study was to determine the effects of maximal intensity exercise on cognitive performance of children. Using a repeated-measures design, 20 children and adolescents aged 8-17 years completed a battery of tests measuring memory and attention. Forward and Backward Digit Span tests, the Rey Auditory-Verbal Learning Test (RAVLT and the Digit Symbol Substitution Test (DSST were performed at baseline, immediately after, and one hour after a maximal cardiopulmonary exercise test. Forward and Backward Digit Span scores significantly improved post-recovery compared with baseline measurements. There was a significant decrease in RAVLT scores post-exercise, which returned to baseline values after recovery. The DSST test scores were mildly elevated from post-exercise to after recovery. Maximal intensity exercise in children and adolescents may result in both beneficial and detrimental cognitive effects, including transient impairment in verbal learning. Cognitive functions applying short term memory improve following a recovery period. Parents, educators and coaches should consider these changes in memory and attention following high-intensity exercise activities in children.

  18. Light-intensity and high-intensity interval training improve cardiometabolic health in rats.

    Science.gov (United States)

    Batacan, Romeo B; Duncan, Mitch J; Dalbo, Vincent J; Connolly, Kylie J; Fenning, Andrew S

    2016-09-01

    Physical activity has the potential to reduce cardiometabolic risk factors but evaluation of different intensities of physical activity and the mechanisms behind their health effects still need to be fully established. This study examined the effects of sedentary behaviour, light-intensity training, and high-intensity interval training on biometric indices, glucose and lipid metabolism, inflammatory and oxidative stress markers, and vascular and cardiac function in adult rats. Rats (12 weeks old) were randomly assigned to 1 of 4 groups: control (CTL; no exercise), sedentary (SED; no exercise and housed in small cages to reduce activity), light-intensity trained (LIT; four 30-min exercise bouts/day at 8 m/min separated by 2-h rest period, 5 days/week), and high-intensity interval trained (HIIT, four 2.5-min work bouts/day at 50 m/min separated by 3-min rest periods, 5 days/week). After 12 weeks of intervention, SED had greater visceral fat accumulation (p < 0.01) and slower cardiac conduction (p = 0.04) compared with the CTL group. LIT and HIIT demonstrated beneficial changes in body weight, visceral and epididymal fat weight, glucose regulation, low-density lipoprotein cholesterol, total cholesterol, and mesenteric vessel contractile response compared with the CTL group (p < 0.05). LIT had significant improvements in insulin sensitivity and cardiac conduction compared with the CTL and SED groups whilst HIIT had significant improvements in systolic blood pressure and endothelium-independent vasodilation to aorta and mesenteric artery compared with the CTL group (p < 0.05). LIT and HIIT induce health benefits by improving traditional cardiometabolic risk factors. LIT improves cardiac health while HIIT promotes improvements in vascular health.

  19. Thomson scattering in high-intensity chirped laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Holkundkar, Amol R., E-mail: amol.holkundkar@pilani.bits-pilani.ac.in [Department of Physics, Birla Institute of Technology and Science, Pilani, Rajasthan 333031 (India); Harvey, Chris, E-mail: christopher.harvey@chalmers.se; Marklund, Mattias, E-mail: mattias.marklund@chalmers.se [Department of Applied Physics, Chalmers University of Technology, SE-41296 Gothenburg (Sweden)

    2015-10-15

    We consider the Thomson scattering of an electron in an ultra-intense laser pulse. It is well known that at high laser intensities, the frequency and brilliance of the emitted radiation will be greatly reduced due to the electron losing energy before it reaches the peak field. In this work, we investigate the use of a small frequency chirp in the laser pulse in order to mitigate this effect of radiation reaction. It is found that the introduction of a negative chirp means the electron enters a high frequency region of the field while it still has a large proportion of its original energy. This results in a significant enhancement of the frequency and intensity of the emitted radiation as compared to the case without chirping.

  20. Plasma-based polarization modulator for high-intensity lasers

    Science.gov (United States)

    Chen, Zi-Yu; Pukhov, Alexander

    2016-12-01

    Manipulation of laser pulses at high intensities is an important yet challenging issue. New types of plasma-based optical devices are promising alternatives to achieve this goal. Here we propose to modulate the polarization state of intense lasers based on oblique reflection from solid-plasma surfaces. A new analytical description is presented considering the plasma as an uniaxial medium that causes birefringence effect. Particle-in-cell simulation results numerically demonstrate that such a scheme can provide a tunable polarization control of the laser pulses even in the relativistic regime. The results are thus relevant for the design of compact, easy to use, and versatile polarization modulators for high-intensity laser pulses.

  1. Self-trapping of intensities changing under SHG and SWG for high intensive femtosecond laser pulse

    Science.gov (United States)

    Trofimov, Vyacheslav A.; Kharitonov, Dmitry M.; Fedotov, Mikhail V.

    2017-05-01

    SHG and SFG (SWG) and THG are used widely in many practical applications such as a substance diagnostics, and imaging of various physical, chemical and biological processes as well as for laser radiation frequency conversion. One of very interesting phenomena under the frequency conversion takes place if a basic wave incident intensity is enough high: a synchronic mode of the laser pulse intensities changing along a propagation coordinate appears under certain conditions. First of all, we investigate this phenomenon using the frame-work of long pulse duration approximation and plane wave approximation without applying the basic wave energy non-depletion approximation. Applying an original approach we derive the solution of Schr¨odinger equations describing the THG via a SHG process and summary frequency wave generation (SFG) process for femtosecond pulses. Among many modes of the frequency conversion process under consideration we found out analytically the mode corresponding to synchronous intensities changing for the interacting waves. We derive conditions of such mode realization in dependence of the problem parameters. After that we verify our analytical consideration using a computer simulation of the problem on the base of the corresponding Schr¨odinger equations. Computer simulation shown also a new phenomenon at three-wave interaction: interacting wave intensities changing with two (or more) oscillation periods.

  2. Performance analysis of solar cell arrays in concentrating light intensity

    Institute of Scientific and Technical Information of China (English)

    Xu Yongfeng; Li Ming; Wang Liuling; Lin Wenxian; Xiang Ming; Zhang Xinghua; Wang Yunfeng; Wei Shengxian

    2009-01-01

    tage in concentrating light intensity. The output power has a -20 W/V coefficient and so cooling fluid must be used. Both heat energy and electrical power are then obtained with a solar trough concentrating photovoltaic/thermal system.

  3. High Performance Thin Layer Chromatography.

    Science.gov (United States)

    Costanzo, Samuel J.

    1984-01-01

    Clarifies where in the scheme of modern chromatography high performance thin layer chromatography (TLC) fits and why in some situations it is a viable alternative to gas and high performance liquid chromatography. New TLC plates, sample applications, plate development, and instrumental techniques are considered. (JN)

  4. High Performance Thin Layer Chromatography.

    Science.gov (United States)

    Costanzo, Samuel J.

    1984-01-01

    Clarifies where in the scheme of modern chromatography high performance thin layer chromatography (TLC) fits and why in some situations it is a viable alternative to gas and high performance liquid chromatography. New TLC plates, sample applications, plate development, and instrumental techniques are considered. (JN)

  5. High-Performance Data Converters

    DEFF Research Database (Denmark)

    Steensgaard-Madsen, Jesper

    Novel techniques for multi-bit oversampled data conversion are described. State-of-the-art oversampled data converters are analyzed, leading to the conclusion that their performance is limited mainly by low-resolution signal representation. To increase the resolution, high-performance, high...

  6. Some Intensive and Extensive Quantities in High-Energy Collisions

    CERN Document Server

    Tawfik, A

    2013-01-01

    We review the evolution of some statistical and thermodynamical quantities measured in difference sizes of high-energy collisions at different energies. We differentiate between intensive and extensive quantities and discuss the importance of their distinguishability in characterizing possible critical phenomena of nuclear collisions at various energies with different initial conditions.

  7. High-Intensity Interval Training for Improving Postprandial Hyperglycemia

    Science.gov (United States)

    Little, Jonathan P.; Francois, Monique E.

    2014-01-01

    High-intensity interval training (HIIT) has garnered attention in recent years as a time-efficient exercise option for improving cardiovascular and metabolic health. New research demonstrates that HIIT may be particularly effective for improving postprandial hyperglycemia in individuals with, or at risk for, type 2 diabetes (T2D). These findings…

  8. Nonlinear Behavior in High-Intensity Discharge Lamps

    CERN Document Server

    Baumann, Bernd; Wolff, Marcus; Manders, Freddy; Suijker, Jos

    2015-01-01

    The light flicker problem of high intensity discharge lamps is studied numerically and experimentally. It is shown that in some respects the systems behaves very similar to the forced Duffing oscillator with a softening spring. In particular, the jump phenomenon and hysteresis are observed in the simulations and in the experiments.

  9. Nonlinear behavior in high-intensity discharge lamps

    Science.gov (United States)

    Baumann, Bernd; Schwieger, Joerg; Wolff, Marcus; Manders, Freddy; Suijker, Jos

    2016-06-01

    The light flicker problem of high intensity discharge lamps is studied numerically and experimentally. It is shown that in some respects the systems behave very similar to the forced Duffing oscillator with a softening spring. In particular, the jump phenomenon and hysteresis are observed in the simulations and in the experiments.

  10. Parallel Beam Dynamics Code Development for High Intensity Cyclotron

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>1 Parallel PIC algorithm Self field solver is the key part of a high intensity beam dynamic PIC code which usually adopts the P-M (Particle-Mesh) method to solve the space charge. The P-M method is composed of four major

  11. Annotated bibliography on high-intensity linear accelerators. [240 citations

    Energy Technology Data Exchange (ETDEWEB)

    Jameson, R.A.; Roybal, E.U.

    1978-01-01

    A technical bibliography covering subjects important to the design of high-intensity beam transport systems and linear accelerators is presented. Space charge and emittance growth are stressed. Subject and author concordances provide cross-reference to detailed citations, which include an abstract and notes on the material. The bibliography resides in a computer database that can be searched for key words and phrases.

  12. Intense neutron source: high-voltage power supply specifications

    Energy Technology Data Exchange (ETDEWEB)

    Riedel, A.A.

    1980-08-01

    This report explains the need for and sets forth the electrical, mechanical and safety specifications for a high-voltage power supply to be used with the intense neutron source. It contains sufficient information for a supplier to bid on such a power supply.

  13. Reuse Recycler: High Intensity Proton Stacking at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, P. [Fermilab

    2016-07-17

    After a successful career as an antiproton storage and cooling ring, Recycler has been converted to a high intensity proton stacker for the Main Injector. We discuss the commissioning and operation of the Recycler in this new role, and the progress towards the 700 kW design goal.

  14. Production of High-Intensity, Highly Charged Ions

    CERN Document Server

    Gammino, S

    2013-01-01

    In the past three decades, the development of nuclear physics facilities for fundamental and applied science purposes has required an increasing current of multicharged ion beams. Multiple ionization implies the formation of dense and energetic plasmas, which, in turn, requires specific plasma trapping configurations. Two types of ion source have been able to produce very high charge states in a reliable and reproducible way: electron beam ion sources (EBIS) and electron cyclotron resonance ion sources (ECRIS). Multiple ionization is also obtained in laser-generated plasmas (laser ion sources (LIS)), where the high-energy electrons and the extremely high electron density allow step-by-step ionization, but the reproducibility is poor. This chapter discusses the atomic physics background at the basis of the production of highly charged ions and describes the scientific and technological features of the most advanced ion sources. Particular attention is paid to ECRIS and the latest developments, since they now r...

  15. Towards optical intensity interferometry for high angular resolution stellar astrophysics

    CERN Document Server

    Nunez, Paul D

    2012-01-01

    Most neighboring stars are still detected as point sources and are beyond the angular resolution reach of current observatories. Methods to improve our understanding of stars at high angular resolution are investigated. Air Cherenkov telescopes (ACTs), primarily used for Gamma-ray astronomy, enable us to increase our understanding of the circumstellar environment of a particular system. When used as optical intensity interferometers, future ACT arrays will allow us to detect stars as extended objects and image their surfaces at high angular resolution. Optical stellar intensity interferometry (SII) with ACT arrays, composed of nearly 100 telescopes, will provide means to measure fundamental stellar parameters and also open the possibility of model-independent imaging. A data analysis algorithm is developed and permits the reconstruction of high angular resolution images from simulated SII data. The capabilities and limitations of future ACT arrays used for high angular resolution imaging are investigated via ...

  16. Effects of Different Exercise Strategies and Intensities on Memory Performance and Neurogenesis

    Science.gov (United States)

    Diederich, Kai; Bastl, Anna; Wersching, Heike; Teuber, Anja; Strecker, Jan-Kolja; Schmidt, Antje; Minnerup, Jens; Schäbitz, Wolf-Rüdiger

    2017-01-01

    It is well established that physical exercise affects both hippocampal neurogenesis and memory functions. Until now, distinctive effects of controlled and voluntary training (VT) on behavior and neurogenesis as well as interactions between exercise intensity, neurogenesis and memory performance are still elusive. The present study tested the impact of moderate controlled and VT on memory formation and hippocampal neurogenesis and evaluated interactions between exercise performance, learning efficiency and proliferation of progenitor cells in the hippocampus. Our data show that both controlled and VT augmented spatial learning and promoted hippocampal neurogenesis. Regression analysis revealed a significant linear increase of the amount of new hippocampal neurons with increased exercise intensity. Regression analysis of exercise performance on retention memory performance revealed a quadratic, inverted u-shaped relationship between exercise performance and retention of spatial memory. No association was found between the amount of newborn neurons and memory performance. Our results demonstrate that controlled training (CT), if performed with an appropriate combination of speed and duration, improves memory performance and neurogenesis. Voluntary exercise elevates neurogenesis dose dependently to high levels. Best cognitive improvement was achieved with moderate exercise performance. PMID:28360847

  17. High intensity ultrasound transducer used in gene transfection

    Science.gov (United States)

    Morrison, Kyle P.; Keilman, George W.; Noble, Misty L.; Brayman, Andrew A.; Miao, Carol H.

    2012-11-01

    This paper describes a novel therapeutic high intensity non-focused ultrasound (HIU) transducer designed with uniform pressure distribution to aid in accelerated gene transfer in large animal liver tissues in vivo. The underlying HIU transducer was used to initiate homogeneous cavitation throughout the tissue while delivering up to 2.7 MPa at 1.1 MHz across its radiating surface. The HIU transducer was built into a 6 cm diameter x 1.3 cm tall housing ergonomically designed to avoid collateral damage to the surrounding anatomy during dynamic motion. The ultrasound (US) radiation was applied in a 'paintbrush-like' manner to the surface of the liver. The layers and geometry of the transducer were carefully selected to maximize the active diameter (5.74 cm), maximize the electrical to acoustic conversion efficiency (85%) to achieve 2.7 MPa of peak negative pressure, maximize the frequency operating band at the fundamental resonance to within a power transfer delta of 1 dB, and reduce the pressure delta to within 2 dB across the radiating surface. For maximum peak voltage into the transducer, a high performance piezoceramic was chosen and a DC bias circuit was built integral to the system. An apodized two element annular pattern was made from a single piezoceramic element, resulting in significant pressure uniformity enhancement. In addition to using apodization for pressure uniformity, a proprietary multi-layered structure was used to improve efficiency while sustaining an operating band from 900 kHz to 1.3 MHz. The resultant operating band allowed for dithering techniques using frequency modulation. The underlying HIU transducer for use in large animals enhances gene expression up to 6300-fold.

  18. Short-term effects of implemented high intensity shoulder elevation during computer work

    Directory of Open Access Journals (Sweden)

    Madeleine Pascal

    2009-08-01

    Full Text Available Abstract Background Work-site strength training sessions are shown effective to prevent and reduce neck-shoulder pain in computer workers, but difficult to integrate in normal working routines. A solution for avoiding neck-shoulder pain during computer work may be to implement high intensity voluntary contractions during the computer work. However, it is unknown how this may influence productivity, rate of perceived exertion (RPE as well as activity and rest of neck-shoulder muscles during computer work. The aim of this study was to investigate short-term effects of a high intensity contraction on productivity, RPE and upper trapezius activity and rest during computer work and a subsequent pause from computer work. Methods 18 female computer workers performed 2 sessions of 15 min standardized computer mouse work preceded by 1 min pause with and without prior high intensity contraction of shoulder elevation. RPE was reported, productivity (drawings per min measured, and bipolar surface electromyography (EMG recorded from the dominant upper trapezius during pauses and sessions of computer work. Repeated measure ANOVA with Bonferroni corrected post-hoc tests was applied for the statistical analyses. Results The main findings were that a high intensity shoulder elevation did not modify RPE, productivity or EMG activity of the upper trapezius during the subsequent pause and computer work. However, the high intensity contraction reduced the relative rest time of the uppermost (clavicular trapezius part during the subsequent pause from computer work (p Conclusion Since a preceding high intensity shoulder elevation did not impose a negative impact on perceived effort, productivity or upper trapezius activity during computer work, implementation of high intensity contraction during computer work to prevent neck-shoulder pain may be possible without affecting the working routines. However, the unexpected reduction in clavicular trapezius rest during a

  19. High Performance Networks for High Impact Science

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Mary A.; Bair, Raymond A.

    2003-02-13

    This workshop was the first major activity in developing a strategic plan for high-performance networking in the Office of Science. Held August 13 through 15, 2002, it brought together a selection of end users, especially representing the emerging, high-visibility initiatives, and network visionaries to identify opportunities and begin defining the path forward.

  20. Ionization Chambers for Monitoring in High-Intensity Neutrino Beams

    CERN Document Server

    McDonald, J; Velissaris, C; Erwin, A R; Ping, H; Viren, B M; Diwan, M V

    2002-01-01

    Radiation-hard ionization chambers were tested using an intense electron beam from the accelerator test facility (ATF) at the Brookhaven National Laboratory (BNL). The detectors were designed to be used as the basic element for monitoring muons in the Main Injector Neutrino beamline (NuMI) at the Fermi National Accelerator Laboratory (FNAL). Measurements of linearity of response, voltage dependence, and the onset of ionization saturation as a function of gap voltage were performed.

  1. Production of High-Intensity, Highly Charged Ions

    OpenAIRE

    S. GamminoINFN, LNS, Catania

    2014-01-01

    In the past three decades, the development of nuclear physics facilities for fundamental and applied science purposes has required an increasing current of multicharged ion beams. Multiple ionization implies the formation of dense and energetic plasmas, which, in turn, requires specific plasma trapping configurations. Two types of ion source have been able to produce very high charge states in a reliable and reproducible way: electron beam ion sources (EBIS) and electron cyc...

  2. CW high intensity non-scaling FFAG proton drivers

    CERN Document Server

    Johnstone, C; Makino, K; Snopok, P

    2012-01-01

    Accelerators are playing increasingly important roles in basic science, technology, and medicine including nuclear power, industrial irradiation, material science, and neutrino production. Proton and light-ion accelerators in particular have many research, energy and medical applications, providing one of the most effective treatments for many types of cancer. Ultra high-intensity and high-energy (GeV) proton drivers are a critical technology for accelerator-driven sub-critical reactors (ADS) and many HEP programs (Muon Collider). These high-intensity GeV-range proton drivers are particularly challenging, encountering duty cycle and space-charge limits in the synchrotron and machine size concerns in the weaker-focusing cyclotrons; a 10-20 MW proton driver is not presently considered technically achievable with conventional re-circulating accelerators. One, as-yet, unexplored re-circulating accelerator, the Fixed-field Alternating Gradient, or FFAG, is an attractive alternative to the cyclotron. Its strong foc...

  3. Crystalline silicon cell performance at low light intensities

    NARCIS (Netherlands)

    Reich, N.H.|info:eu-repo/dai/nl/30483453X; van Sark, W.G.J.H.M.|info:eu-repo/dai/nl/074628526; Alsema, E.A.|info:eu-repo/dai/nl/073416258; Lof, R.W.; Schropp, R.E.I.|info:eu-repo/dai/nl/072502584; Sinke, W.C.|info:eu-repo/dai/nl/071641009; Turkenburg, W.C.|info:eu-repo/dai/nl/073416355

    2009-01-01

    Measured and modelled JV characteristics of crystalline silicon cells below one sun intensity have been investigated. First, the JV characteristics were measured between 3 and 1000 W/m2 at 6 light levels for 41 industrially produced mono- and multi-crystalline cells from 8 manufacturers, and at 29 i

  4. Functional High Performance Financial IT

    DEFF Research Database (Denmark)

    Berthold, Jost; Filinski, Andrzej; Henglein, Fritz

    2011-01-01

    The world of finance faces the computational performance challenge of massively expanding data volumes, extreme response time requirements, and compute-intensive complex (risk) analyses. Simultaneously, new international regulatory rules require considerably more transparency and external...... auditability of financial institutions, including their software systems. To top it off, increased product variety and customisation necessitates shorter software development cycles and higher development productivity. In this paper, we report about HIPERFIT, a recently etablished strategic research center...... at the University of Copenhagen that attacks this triple challenge of increased performance, transparency and productivity in the financial sector by a novel integration of financial mathematics, domain-specific language technology, parallel functional programming, and emerging massively parallel hardware. HIPERFIT...

  5. RavenDB high performance

    CERN Document Server

    Ritchie, Brian

    2013-01-01

    RavenDB High Performance is comprehensive yet concise tutorial that developers can use to.This book is for developers & software architects who are designing systems in order to achieve high performance right from the start. A basic understanding of RavenDB is recommended, but not required. While the book focuses on advanced topics, it does not assume that the reader has a great deal of prior knowledge of working with RavenDB.

  6. High-Performance Operating Systems

    DEFF Research Database (Denmark)

    Sharp, Robin

    1999-01-01

    Notes prepared for the DTU course 49421 "High Performance Operating Systems". The notes deal with quantitative and qualitative techniques for use in the design and evaluation of operating systems in computer systems for which performance is an important parameter, such as real-time applications......, communication systems and multimedia systems....

  7. High-Performance Operating Systems

    DEFF Research Database (Denmark)

    Sharp, Robin

    1999-01-01

    Notes prepared for the DTU course 49421 "High Performance Operating Systems". The notes deal with quantitative and qualitative techniques for use in the design and evaluation of operating systems in computer systems for which performance is an important parameter, such as real-time applications......, communication systems and multimedia systems....

  8. Generation of Ultra-high Intensity Laser Pulses

    Energy Technology Data Exchange (ETDEWEB)

    N.J. Fisch; V.M. Malkin

    2003-06-10

    Mainly due to the method of chirped pulse amplification, laser intensities have grown remarkably during recent years. However, the attaining of very much higher powers is limited by the material properties of gratings. These limitations might be overcome through the use of plasma, which is an ideal medium for processing very high power and very high total energy. A plasma can be irradiated by a long pump laser pulse, carrying significant energy, which is then quickly depleted in the plasma by a short counterpropagating pulse. This counterpropagating wave effect has already been employed in Raman amplifiers using gases or plasmas at low laser power. Of particular interest here are the new effects which enter in high power regimes. These new effects can be employed so that one high-energy optical system can be used like a flashlamp in what amounts to pumping the plasma, and a second low-power optical system can be used to extract quickly the energy from the plasma and focus it precisely. The combined system can be very compact. Thus, focused intensities more than 10{sup 25} W/cm{sup 2} can be contemplated using existing optical elements. These intensities are several orders of magnitude higher than what is currently available through chirped pump amplifiers.

  9. A transparent vacuum window for high-intensity pulsed beams

    CERN Document Server

    Monteil, M; Veness, R

    2011-01-01

    The HiRadMat (High-Radiation to Materials) facility Ill will allow testing of accelerator components, in particular those of the Large Hadron Collider (LHC) at CERN, under the impact of high-intensity pulsed beams. To reach this intensity range, the beam will be focused on a focal point where the target to be tested is located. A 60 mm aperture vacuum window will separate the vacuum of the beam line which is kept under high vacuum 10(-8) mbar, from the test area which is at atmospheric pressure. This window has to resist collapse due to beam passage. The high-intensity of the beam means that typical materials used for standard vacuum windows (such as stainless steel, aluminium and titanium alloy) cannot endure the energy deposition induced by the beam passage. Therefore, a vacuum window has been designed to maintain the differential pressure whilst resisting collapse due to the beam impact on the window. In this paper, we will present calculations of the energy transfer from beam to window, the design of the ...

  10. Nutritional strategies to support adaptation to high-intensity interval training in team sports.

    Science.gov (United States)

    Gibala, Martin J

    2013-01-01

    Team sports are characterized by intermittent high-intensity activity patterns. Typically, play consists of short periods of very intense or all-out efforts interspersed with longer periods of low-intensity activity. Fatigue is a complex, multi-factorial process, but intense intermittent exercise performance can potentially be limited by reduced availability of substrates stored in skeletal muscle and/or metabolic by-products associated with fuel breakdown. High-intensity interval training (HIT) has been shown to induce adaptations in skeletal muscle that enhance the capacity for both oxidative and non-oxidative metabolism. Nutrient availability is a potent modulator of many acute physiological responses to exercise, including various molecular signaling pathways that are believed to regulate cellular adaptation to training. Several nutritional strategies have also been reported to acutely alter metabolism and enhance intermittent high-intensity exercise performance. However, relatively little is known regarding the effect of chronic interventions, and whether supplementation over a period of weeks or months augments HIT-induced physiological remodeling and promotes greater performance adaptations. Theoretically, a nutritional intervention could augment HIT adaptation by improving energy metabolism during exercise, which could facilitate greater total work and an enhanced chronic training stimulus, or promoting some aspect of the adaptive response during recovery, which could lead to enhanced physiological adaptations over time.

  11. Heat transparent high intensity high efficiency solar cell

    Science.gov (United States)

    Evans, J. C., Jr. (Inventor)

    1982-01-01

    An improved solar cell design is described. A surface of each solar cell has a plurality of grooves. Each groove has a vertical face and a slanted face that is covered by a reflecting metal. Light rays are reflected from the slanted face through the vertical face where they traverse a photovoltaic junction. As the light rays travel to the slanted face of an adjacent groove, they again traverse the junction. The underside of the reflecting coating directs the light rays toward the opposite surface of solar cell as they traverse the junction again. When the light rays travel through the solar cell and reach the saw toothed grooves on the under side, the process of reflection and repeatedly traversing the junction again takes place. The light rays ultimately emerge from the solar cell. These solar cells are particularly useful at very high levels of insolation because the infrared or heat radiation passes through the cells without being appreciably absorbed to heat the cell.

  12. Dietary nitrate supplementation improves team sport-specific intense intermittent exercise performance.

    Science.gov (United States)

    Wylie, Lee J; Mohr, Magni; Krustrup, Peter; Jackman, Sarah R; Ermιdis, Georgios; Kelly, James; Black, Matthew I; Bailey, Stephen J; Vanhatalo, Anni; Jones, Andrew M

    2013-07-01

    Recent studies have suggested that dietary inorganic nitrate (NO₃(-)) supplementation may improve muscle efficiency and endurance exercise tolerance but possible effects during team sport-specific intense intermittent exercise have not been examined. We hypothesized that NO₃(-) supplementation would enhance high-intensity intermittent exercise performance. Fourteen male recreational team-sport players were assigned in a double-blind, randomized, crossover design to consume 490 mL of concentrated, nitrate-rich beetroot juice (BR) and nitrate-depleted placebo juice (PL) over ~30 h preceding the completion of a Yo-Yo intermittent recovery level 1 test (Yo-Yo IR1). Resting plasma nitrite concentration ([NO₂(-)]) was ~400% greater in BR compared to PL. Plasma [NO₂(-)] declined by 20% in PL (P exercise to end-exercise. Performance in the Yo-Yo IR1 was 4.2% greater (P exercise and may be a useful ergogenic aid for team sports players.

  13. High-Intensity Focused Ultrasound Therapy: an Overview for Radiologists

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Sun; Rhim, Hyun Chul; Lim, Hyo Keun; Choi, Dong Il [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Choi, Min Joo [College of Medicine, Cheju National University, Jeju (Korea, Republic of)

    2008-08-15

    High-intensity focused ultrasound therapy is a novel, emerging, therapeutic modality that uses ultrasound waves, propagated through tissue media, as carriers of energy. This completely non-invasive technology has great potential for tumor ablation as well as hemostasis, thrombolysis and targeted drug/gene delivery. However, the application of this technology still has many drawbacks. It is expected that current obstacles to implementation will be resolved in the near future. In this review, we provide an overview of high-intensity focused ultrasound therapy from the basic physics to recent clinical studies with an interventional radiologist's perspective for the purpose of improving the general understanding of this cutting-edge technology as well as speculating on future developments

  14. High-intensity focused ultrasound therapy: an overview for radiologists.

    Science.gov (United States)

    Kim, Young-sun; Rhim, Hyunchul; Choi, Min Joo; Lim, Hyo Keun; Choi, Dongil

    2008-01-01

    High-intensity focused ultrasound therapy is a novel, emerging, therapeutic modality that uses ultrasound waves, propagated through tissue media, as carriers of energy. This completely non-invasive technology has great potential for tumor ablation as well as hemostasis, thrombolysis and targeted drug/gene delivery. However, the application of this technology still has many drawbacks. It is expected that current obstacles to implementation will be resolved in the near future. In this review, we provide an overview of high-intensity focused ultrasound therapy from the basic physics to recent clinical studies with an interventional radiologist's perspective for the purpose of improving the general understanding of this cutting-edge technology as well as speculating on future developments.

  15. Fermilab main injector: High intensity operation and beam loss control

    Science.gov (United States)

    Brown, Bruce C.; Adamson, Philip; Capista, David; Chou, Weiren; Kourbanis, Ioanis; Morris, Denton K.; Seiya, Kiyomi; Wu, Guan Hong; Yang, Ming-Jen

    2013-07-01

    From 2005 through 2012, the Fermilab Main Injector provided intense beams of 120 GeV protons to produce neutrino beams and antiprotons. Hardware improvements in conjunction with improved diagnostics allowed the system to reach sustained operation at 400 kW beam power. Transmission was very high except for beam lost at or near the 8 GeV injection energy where 95% beam transmission results in about 1.5 kW of beam loss. By minimizing and localizing loss, residual radiation levels fell while beam power was doubled. Lost beam was directed to either the collimation system or to the beam abort. Critical apertures were increased while improved instrumentation allowed optimal use of available apertures. We will summarize the improvements required to achieve high intensity, the impact of various loss control tools and the status and trends in residual radiation in the Main Injector.

  16. Ergogenic effects of caffeine and sodium bicarbonate supplementation on intermittent exercise performance preceded by intense arm cranking exercise

    DEFF Research Database (Denmark)

    Marriott, Matthaus; Krustrup, Peter; Mohr, Magni

    2015-01-01

    BACKGROUND: Caffeine and sodium bicarbonate ingestion have been suggested to improve high-intensity intermittent exercise, but it is unclear if these ergogenic substances affect performance under provoked metabolic acidification. To study the effects of caffeine and sodium bicarbonate on intense...... intermittent exercise performance and metabolic markers under exercise-induced acidification, intense arm-cranking exercise was performed prior to intense intermittent running after intake of placebo, caffeine and sodium bicarbonate. METHODS: Male team-sports athletes (n = 12) ingested sodium bicarbonate (Na......HCO3; 0.4 g.kg(-1) b.w.), caffeine (CAF; 6 mg.kg(-1) b.w.) or placebo (PLA) on three different occasions. Thereafter, participants engaged in intense arm exercise prior to the Yo-Yo intermittent recovery test level-2 (Yo-Yo IR2). Heart rate, blood lactate and glucose as well as rating of perceived...

  17. High-Intensity Intermittent Swimming Improves Cardiovascular Health Status for Women with Mild Hypertension

    Directory of Open Access Journals (Sweden)

    Magni Mohr

    2014-01-01

    Full Text Available To test the hypothesis that high-intensity swim training improves cardiovascular health status in sedentary premenopausal women with mild hypertension, sixty-two women were randomized into high-intensity (n=21; HIT, moderate-intensity (n=21; MOD, and control groups (n=20; CON. HIT performed 6–10 × 30 s all-out swimming interspersed by 2 min recovery and MOD swam continuously for 1 h at moderate intensity for a 15-week period completing in total 44±1 and 43±1 sessions, respectively. In CON, all measured variables were similar before and after the intervention period. Systolic BP decreased (P<0.05 by 6±1 and 4±1 mmHg in HIT and MOD; respectively. Resting heart rate declined (P<0.05 by 5±1 bpm both in HIT and MOD, fat mass decreased (P<0.05 by 1.1±0.2 and 2.2±0.3 kg, respectively, while the blood lipid profile was unaltered. In HIT and MOD, performance improved (P<0.05 for a maximal 10 min swim (13±3% and 22±3%, interval swimming (23±3% and 8±3%, and Yo-Yo IE1 running performance (58±5% and 45±4%. In conclusion, high-intensity intermittent swimming is an effective training strategy to improve cardiovascular health and physical performance in sedentary women with mild hypertension. Adaptations are similar with high- and moderate-intensity training, despite markedly less total time spent and distance covered in the high-intensity group.

  18. Spallation neutron source and other high intensity froton sources

    Energy Technology Data Exchange (ETDEWEB)

    Weiren Chou

    2003-02-06

    This lecture is an introduction to the design of a spallation neutron source and other high intensity proton sources. It discusses two different approaches: linac-based and synchrotron-based. The requirements and design concepts of each approach are presented. The advantages and disadvantages are compared. A brief review of existing machines and those under construction and proposed is also given. An R&D program is included in an appendix.

  19. Entrepreneurship in high-tech and knowledge-intensive sectors

    DEFF Research Database (Denmark)

    Christensen, Patrizia V.; Madsen, Henning; Neergaard, Helle

    development of new enterprises in high-tech and knowledge-intensive sectors are analysed in relation to the educational and professional background of the entrepreneur/entrepreneurial team, as well as the personal and professional social networks of the entrepreneurs. The analysis is based on a theoretical...... framework combining theories of human and social capital. Secondary aspects addressed in the research project are questions of male vs. female entrepreneurship, internationalisation-globalisation, and business success/failure....

  20. Biomechanics, energetics and coordination during extreme swimming intensity: effect of performance level.

    Science.gov (United States)

    Ribeiro, João; Figueiredo, Pedro; Morais, Sara; Alves, Francisco; Toussaint, Huub; Vilas-Boas, João Paulo; Fernandes, Ricardo Jorge

    2017-08-01

    The present study aimed to examine how high- and low-speed swimmers organise biomechanical, energetic and coordinative factors throughout extreme intensity swim. Sixteen swimmers (eight high- and eight low-speed) performed, in free condition, 100-m front crawl at maximal intensity and 25, 50 and 75-m bouts (at same pace as the previous 100-m), and 100-m maximal front crawl on the measuring active drag system (MAD-system). A 3D dual-media optoelectronic system was used to assess speed, stroke frequency, stroke length, propelling efficiency and index of coordination (IdC), with power assessed by MAD-system and energy cost by quantifying oxygen consumption plus blood lactate. Both groups presented a similar profile in speed, power output, stroke frequency, stroke length, propelling efficiency and energy cost along the effort, while a distinct coordination profile was observed (F(3, 42) = 3.59, P = 0.04). Speed, power, stroke frequency and propelling efficiency (not significant, only a tendency) were higher in high-speed swimmers, while stroke length and energy cost were similar between groups. Performing at extreme intensity led better level swimmers to achieve superior speed due to higher power and propelling efficiency, with consequent ability to swim at higher stroke frequencies. This imposes specific constraints, resulting in a distinct IdC magnitude and profile between groups.

  1. High-Performance Ball Bearing

    Science.gov (United States)

    Bursey, Roger W., Jr.; Haluck, David A.; Olinger, John B.; Owen, Samuel S.; Poole, William E.

    1995-01-01

    High-performance bearing features strong, lightweight, self-lubricating cage with self-lubricating liners in ball apertures. Designed to operate at high speed (tens of thousands of revolutions per minute) in cryogenic environment like liquid-oxygen or liquid-hydrogen turbopump. Includes inner race, outer race, and cage keeping bearing balls equally spaced.

  2. High-Performance Ball Bearing

    Science.gov (United States)

    Bursey, Roger W., Jr.; Haluck, David A.; Olinger, John B.; Owen, Samuel S.; Poole, William E.

    1995-01-01

    High-performance bearing features strong, lightweight, self-lubricating cage with self-lubricating liners in ball apertures. Designed to operate at high speed (tens of thousands of revolutions per minute) in cryogenic environment like liquid-oxygen or liquid-hydrogen turbopump. Includes inner race, outer race, and cage keeping bearing balls equally spaced.

  3. Beam Dynamics Observations of the 2015 High Intensity Scrubbing Runs at the Cern Sps

    CERN Document Server

    Bartosik, Hannes; Li, Kevin; Mether, Lotta; Romano, Annalisa; Rumolo, Giovanni; Schenk, Michael

    2016-01-01

    Beam quality degradation caused by e-cloud effects has been identified as one of the main performance limitations for high intensity LHC beams with 25 ns bunch spacing in the SPS. In view of the beam parameters targeted with the LHC injectors upgrade (LIU) project, about two weeks of SPS machine time in 2015 were devoted to dedicated scrubbing runs with high intensity LHC 25 ns and dedicated 'doublet' beams in order to study the achievable reduction of e-cloud effects and quantify the consequent beam performance improvements. This paper describes the main observations concerning the coherent instabilities and beam dynamics limitations encountered as well as a detailed characterisation of the performance reach with the highest beam intensity presently available from the pre-injectors.

  4. Low volume short duration high-intensity interval training and repeated sprint ability in Gaelic football players

    OpenAIRE

    Kelly, David

    2014-01-01

    Gaelic Football is the most popular sport in Ireland and is characterized by irregular changes of pace and high-intensity efforts interspersed with periods of light to moderate intensity activity. Speed, power and aerobic capacity are essential fitness components for optimal performance during match play. A high level of aerobic conditioning is required to generate and maintain power output during repeated high intensity activities. Study 1: Anthropometric, physiological, metabolic and en...

  5. Endurance capacity and neuromuscular fatigue following high- vs moderate-intensity endurance training: A randomized trial.

    Science.gov (United States)

    O'Leary, T J; Collett, J; Howells, K; Morris, M G

    2017-02-16

    High-intensity exercise induces significant central and peripheral fatigue; however, the effect of endurance training on these mechanisms of fatigue is poorly understood. We compared the effect of cycling endurance training of disparate intensities on high-intensity exercise endurance capacity and the associated limiting central and peripheral fatigue mechanisms. Twenty adults were randomly assigned to 6 weeks of either high-intensity interval training (HIIT, 6-8×5 minutes at halfway between lactate threshold and maximal oxygen uptake [50%Δ]) or volume-matched moderate-intensity continuous training (CONT, ~60-80 minutes at 90% lactate threshold). Two time to exhaustion (TTE) trials at 50%Δ were completed pre- and post-training to assess endurance capacity; the two post-training trials were completed at the pretraining 50%Δ (same absolute intensity) and the "new" post-training 50%Δ (same relative intensity). Pre- and post-exercise responses to femoral nerve and motor cortex stimulation were examined to determine peripheral and central fatigue, respectively. HIIT resulted in greater increases in TTE at the same absolute and relative intensities as pre-training (148% and 43%, respectively) compared with CONT (38% and -4%, respectively) (P≤.019). Compared with pre-training, HIIT increased the level of potentiated quadriceps twitch reduction (-34% vs -43%, respectively, P=.023) and attenuated the level of voluntary activation reduction (-7% vs -3%, respectively, P=.047) following the TTE trial at the same relative intensity. There were no other training effects on neuromuscular fatigue development. This suggests that central fatigue resistance contributes to enhanced high-intensity exercise endurance capacity after HIIT by allowing greater performance to be extruded from the muscle. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Compton spectra of atoms at high x-ray intensity

    Science.gov (United States)

    Son, Sang-Kil; Geffert, Otfried; Santra, Robin

    2017-03-01

    Compton scattering is the nonresonant inelastic scattering of an x-ray photon by an electron and has been used to probe the electron momentum distribution in gas-phase and condensed-matter samples. In the low x-ray intensity regime, Compton scattering from atoms dominantly comes from bound electrons in neutral atoms, neglecting contributions from bound electrons in ions and free (ionized) electrons. In contrast, in the high x-ray intensity regime, the sample experiences severe ionization via x-ray multiphoton multiple ionization dynamics. Thus, it becomes necessary to take into account all the contributions to the Compton scattering signal when atoms are exposed to high-intensity x-ray pulses provided by x-ray free-electron lasers (XFELs). In this paper, we investigate the Compton spectra of atoms at high x-ray intensity, using an extension of the integrated x-ray atomic physics toolkit, xatom. As the x-ray fluence increases, there is a significant contribution from ionized electrons to the Compton spectra, which gives rise to strong deviations from the Compton spectra of neutral atoms. The present study provides not only understanding of the fundamental XFEL-matter interaction but also crucial information for single-particle imaging experiments, where Compton scattering is no longer negligible. , which features invited work from the best early-career researchers working within the scope of J. Phys. B. This project is part of the Journal of Physics series’ 50th anniversary celebrations in 2017. Sang-Kil Son was selected by the Editorial Board of J. Phys. B as an Emerging Leader.

  7. 高性能战斗机大强度飞行对飞行员生理指标及飞行劳动负荷主观评价的影响%Effects of high intensity flight on physiological indices and subjective evaluation of high performance fighter pilots

    Institute of Scientific and Technical Information of China (English)

    郭华; 周亚军; 郭壁砖; 景百胜; 李全安

    2011-01-01

    Objective To investigate the effects of high intensity flight on physiological indices and subjective evaluation of flight work load of high performance fighter pilot.Methods Five healthy male military pilots executed 22 high intensity flights in one day.Electrocardiograph was recorded during flight,and heart rate and heart rate variability (HRV) were analyzed.Flight work load and subjective fatigue feeling were evaluated by pilots themselves.Results During high intensity flight,heart rate and HRV showed an apparent circadian rhythm.Heart rate,low frequency normalized unit (LFnu) and ratio of low and high frequency (LF/HF)in night time were lower than those in day time,but high frequency normalized unit (HFnu).There was no obvious subjective fatigue feeling commented by pilots.Conclusions High intensity flight of high performance fighter pilots has some effects on physiological indices,but no flight fatigue so far.Rational disposition of flight and adequate aeromedical support could be beneficial to pilot's recovery and the alleviation of flight fatigue.%目的 观察高性能战斗机大强度飞行对飞行员的生理指标及飞行劳动负荷主观评价的影响.方法 5名健康男性高性能战斗机飞行员在1个飞行日内共进行22架次的大强度飞行.记录飞行过程中的心电信号,分析心率及心率变异性(heart rate variability,HRV);飞行后进行飞行劳动负荷和疲劳程度主观评价.结果 飞行员大强度飞行时,随着飞行负荷的降低,心率和HRV频域及时域指标呈现一定的规律性变化.心率在夜间较日间低;夜间校正高频功率(high frequency normalized unit,HFnu)高于日间,校正低频功率(low frequency normalized unit,LFnu)及低频高频比值(LF/HF)则低于日间.飞行员飞行劳动负荷及疲劳程度主观评价分值均较低,没有明显的主观疲劳感.结论 高性能战斗机大强度飞行对飞行员生理指标有一定影响,但尚未引起飞行疲劳.合理的

  8. Intelligent Controller of Digital High Intensity Discharge Lamp

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    High-intensity discharge (HID) lamps include these types of electrical lamps: mercury vapor, metal halide (also HQI), high-pressure sodium, low-pressure sodium and less commonly, xenon short-arc lamps. The light-producing element of these lamp types is a well-stabilized arc discharge contained within a refractory envelope (arc tube) with wall loading in excess of 3 W/cm (19.4 W/in.). Compared to fluorescent and incandescent lamps, HID lamps produce a much larger quantity of light in a relatively small package. With tests made by the National Quality Supervision and

  9. The joint project for high-intensity proton accelerators

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-08-01

    Japan Atomic Energy Research Institute (JAERI) and the High Energy Accelerator Research Organization (KEK) agreed to promote the joint project integrating both the Neutron Science Project (NSP) of JAERI and the Japan Hadron Facility Project (JHF) of KEK for comprehensive studies on basic science and technology using high-intensity proton accelerator. This document describes the joint proposal prepared by the Joint Project Team of JAERI and KEK to construct accelerators and research facilities necessary both for the NSP and the JHF at the site of JAERI Tokai Establishment. (author)

  10. High intensity Discharge lighting; Alumbrado de alta intensidad de descarga

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza E, Ernesto J. [Manufacturera de Reactores, S. A., Mexico, D. F. (Mexico)

    1993-12-31

    This paper gets into contact with some fundamentals in the operation of high discharge intensity lamps. There are useful definitions, as well as the study of the operation of high pressure sodium lamps and of metallic additives operating at less than nominal power. [Espanol] Este trabajo pone al lector en contacto con algunos fundamentos de la operacion de las lamparas de alta intensidad de descarga (HID). Se encuentra con definiciones utiles, asi como el estudio de la operacion de las lamparas de sodio en alta presion y de aditivos metalicos operando a una potencia menor que la nominal.

  11. Removing Known SPS Intensity Limitations for High Luminosity LHC Goals

    CERN Document Server

    Shaposhnikova, Elena; Bohl, Thomas; Cruikshank, Paul; Goddard, Brennan; Kaltenbacher, Thomas; Lasheen, Alexandre; Perez Espinos, Jaime; Repond, Joël; Salvant, Benoit; Vollinger, Christine

    2016-01-01

    In preparation of the SPS as an LHC injector its impedance was significantly reduced in 1999 - 2000. A new SPS impedance reduction campaign is planned now for the High Luminosity (HL)-LHC project, which requires bunch intensities twice as high as the nominal one. One of the known intensity limitations is a longitudinal multi-bunch instability with a threshold 3 times below this operational intensity. The instability is presently cured using the 4th harmonic RF system and controlled emittance blow-up, but reaching the HL-LHC parameters cannot be assured without improving the machine impedance. Recently the impedance sources responsible for this instability were identified and implementation of their shielding and damping is foreseen during the next long shutdown (2019 - 2020) in synergy with two other important upgrades: amorphous carbon coating of (part of) the vacuum chamber against the e-cloud effect and rearrangement of the 200 MHz RF system. In this paper the strategy of impedance reduction is presented t...

  12. Relative Match Intensities at High Altitude in Highly-Trained Young Soccer Players (ISA3600

    Directory of Open Access Journals (Sweden)

    Martin Buchheit

    2015-03-01

    Full Text Available To compare relative match intensities of sea-level versus high-altitude native soccer players during a 2-week camp at 3600 m, data from 7 sea-level (Australian U17 National team, AUS and 6 high-altitude (a Bolivian U18 team, BOL native soccer players were analysed. Two matches were played at sea-level and three at 3600 m on Days 1, 6 and 13. The Yo-Yo Intermittent recovery test (vYo-YoIR1 was performed at sea-level, and on Days 3 and 10. Match activity profiles were measured via 10-Hz GPS. Distance covered >14.4 km.h-1 (D>14.4 km·h-1 and >80% of vYo-YoIR1 (D>80%vYo-YoIR1 were examined. Upon arrival at altitude, there was a greater decrement in vYo-YoIR1 (Cohen’s d +1.0, 90%CL ± 0.8 and D>14.4 km·h-1 (+0.5 ± 0.8 in AUS. D>14.4 km.h-1 was similarly reduced relative to vYo-YoIR1 in both groups, so that D>80%vYo-YoIR1 remained similarly unchanged (-0.1 ± 0.8. Throughout the altitude sojourn, vYo-YoIR1 and D>14.4 km·h-1 increased in parallel in AUS, so that D>80%vYo-YoIR1 remained stable in AUS (+6.0%/match, 90%CL ± 6.7; conversely D>80%vYo-YoIR1 decreased largely in BOL (-12.2%/match ± 6.2. In sea-level natives competing at high-altitude, changes in match running performance likely follow those in high-intensity running performance. Bolivian data confirm that increases in ‘fitness’ do not necessarily translate into greater match running performance, but rather in reduced relative exercise intensity.

  13. Raman forward scattering of high-intensity chirped laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, C.B.; Esarey, E.; Shadwick, B.A.; Leemans, W.P.

    2002-06-23

    Raman forward scattering of a high-intensity, short-duration, frequency-chirped laser pulse propagating in an underdense plasma is examined. The growth of the direct forward scattered light is calculated for a laser pulse with a linear frequency chirp in various spatio-temporal regimes. This includes a previously undescribed regime of strongly-coupled four-wave nonresonant interaction, which is important for relativistic laser intensities. In all regimes of forward scattering, it is shown that the growth rate increases (decreases) for positive (negative) frequency chirp. The effect of chirp on the growth rate is relatively minor, i.e., a few percent chirp yields few percent changes in the growth rates. Relation of these results to recent experiments is discussed.

  14. High intensity ion beams in rf undulator linac

    Directory of Open Access Journals (Sweden)

    E. S. Masunov

    2008-07-01

    Full Text Available The possibility of using a radio frequency undulator field to accelerate a high intensity ion beam in a linac is discussed. Such an accelerator can be realized using the periodical interdigital H-type resonator structure. The accelerating force is produced by an electric field which is a combination of two or more spatial harmonics, none of them being synchronous with the ion beam. The value of this force is proportional to the squared charge. The equations of motion in Hamiltonian form are derived by means of smooth approximation. The analysis of the 3D effective potential function allows finding the conditions of the beam focusing and acceleration. Two ways to increase ion beam intensity are considered: (i to enlarge beam cross section; (ii to neutralize the beam space charge by accelerating ions with opposite charge signs within the same bunch. The basic results are confirmed by a numerical simulation.

  15. High performance scalable image coding

    Institute of Scientific and Technical Information of China (English)

    Gan Tao; He Yanmin; Zhu Weile

    2007-01-01

    A high performance scalable image coding algorithm is proposed. The salient features of this algorithm are the ways to form and locate the significant clusters. Thanks to the list structure, the new coding algorithm achieves fine fractional bit-plane coding with negligible additional complexity. Experiments show that it performs comparably or better than the state-of-the-art coders. Furthermore, the flexible codec supports both quality and resolution scalability, which is very attractive in many network applications.

  16. EFFECT OF HIGH INTENSITY INTERVAL TRAINING ON ENDOTHELIAL FUNCTION IN POSTMENOPAUSAL HYPERTENSIVE PATIENTS RANDOMIZED CONTROLLED TRIAL

    Directory of Open Access Journals (Sweden)

    Mona Mohamed Taha

    2016-02-01

    Full Text Available Background: Postmenopausal hypertension is the most common risk factor of cardiovascular morbidity and mortality. As the exercises training conveys benefits of the setting of secondary prevention of hypertension. High intensity interval training (HIIT emerged as a new form of physical training and presents as therapeutic alternative to patients and health care professionals. This study aimed to investigate the effect of high intensity interval training on endothelial function in postmenopausal hypertension. Methods: Forty six mildly hypertensive postmenopausal women, their ages ranged from (45-55 years old, were randomly allocated to two groups: HIIT group (group-I; n=23 performed a high intensity interval training 3 times a week for 10 weeks at an intensity of (80-85% HR max for 40 minutes and control group (group-II; n=23 remains sedentary during this period. Serum nitric oxide (NO, vascular endothelial growth factor levels (VEGF and blood pressures were measured before and after intervention. Results: A significant reduction in both systolic and diastolic blood pressure values by 9.5% and 7 % respectively, was seen after high intensity interval training which was accompanied by increase in NO and VEGF levels by 43.3% and 15.2 % respectively, while no significant change observed in the control group. Conclusion: High intensity interval training had obvious benefits in improving plasma No, VEGF concentrations and controlling hypertension in postmenopausal women.

  17. Effects of Vigorous Intensity Physical Activity on Mathematics Test Performance

    Science.gov (United States)

    Phillips, David S.; Hannon, James C.; Castelli, Darla M.

    2015-01-01

    The effect of an acute bout of physical activity on academic performance in school-based settings is under researched. The purpose of this study was to examine associations between a single, vigorous (70-85%) bout of physical activity completed during physical education on standardized mathematics test performance among 72, eighth grade students…

  18. The effect of progressive high-intensity inspiratory muscle training and fixed high-intensity inspiratory muscle training on the asymmetry of diaphragm thickness in stroke patients

    OpenAIRE

    Jung, Ju-hyeon; Kim, Nan-soo

    2015-01-01

    [Purpose] This study investigated the effects of progressive load and fixed load high-intensity inspiratory muscle training on the asymmetry of diaphragm thickness in stroke patients. [Subjects] Twenty-one stroke patients were assigned to one of three groups: progressive load high-intensity inspiratory muscle training (n = 8), fixed load high-intensity inspiratory muscle training (n = 6), and controls (n = 7). [Methods] The progressive load and fixed load high-intensity inspiratory muscle tra...

  19. High-intensity exercise attenuates postprandial lipaemia and markers of oxidative stress.

    Science.gov (United States)

    Gabriel, Brendan; Ratkevicius, Aivaras; Gray, Patrick; Frenneaux, Michael P; Gray, Stuart R

    2012-09-01

    Regular exercise can reduce the risk of CVD (cardiovascular disease). Although moderate-intensity exercise can attenuate postprandial TAG (triacylglycerol), high-intensity intermittent exercise might be a more effective method to improve health. We compared the effects of high-intensity intermittent exercise and 30 min of brisk walking on postprandial TAG, soluble adhesion molecules and markers of oxidative stress. Nine men each completed three 2-day trials. On day 1, subjects rested (control), walked briskly for 30 min (walking) or performed 5×30 s maximal sprints (high-intensity). On day 2, subjects consumed a high-fat meal for breakfast and 3 h later for lunch. Blood samples were taken at various times and analysed for TAG, glucose, insulin, ICAM-1 (intracellular adhesion molecule-1), VCAM-1 (vascular adhesion molecule-1), TBARS (thiobarbituric acid- reactive substances), protein carbonyls and β-hydroxybutyrate. On day 2 of the high-intensity trial, there was a lower (Phigh-intensity trial (14.13±2.83 mmol/l per 7 h) compared with control (17.18±3.92 mmol/l per 7 h), walking showed no difference (16.33±3.51 mmol/l per 7 h). On day 2 of the high-intensity trial plasma TBARS and protein carbonyls were also reduced (Phigh-intensity intermittent exercise attenuates postprandial TAG and markers of oxidative stress after the consumption of a high-fat meal.

  20. INL High Performance Building Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Jennifer D. Morton

    2010-02-01

    High performance buildings, also known as sustainable buildings and green buildings, are resource efficient structures that minimize the impact on the environment by using less energy and water, reduce solid waste and pollutants, and limit the depletion of natural resources while also providing a thermally and visually comfortable working environment that increases productivity for building occupants. As Idaho National Laboratory (INL) becomes the nation’s premier nuclear energy research laboratory, the physical infrastructure will be established to help accomplish this mission. This infrastructure, particularly the buildings, should incorporate high performance sustainable design features in order to be environmentally responsible and reflect an image of progressiveness and innovation to the public and prospective employees. Additionally, INL is a large consumer of energy that contributes to both carbon emissions and resource inefficiency. In the current climate of rising energy prices and political pressure for carbon reduction, this guide will help new construction project teams to design facilities that are sustainable and reduce energy costs, thereby reducing carbon emissions. With these concerns in mind, the recommendations described in the INL High Performance Building Strategy (previously called the INL Green Building Strategy) are intended to form the INL foundation for high performance building standards. This revised strategy incorporates the latest federal and DOE orders (Executive Order [EO] 13514, “Federal Leadership in Environmental, Energy, and Economic Performance” [2009], EO 13423, “Strengthening Federal Environmental, Energy, and Transportation Management” [2007], and DOE Order 430.2B, “Departmental Energy, Renewable Energy, and Transportation Management” [2008]), the latest guidelines, trends, and observations in high performance building construction, and the latest changes to the Leadership in Energy and Environmental Design

  1. FUNDAMENTALS OF HIGH PERFORMANCE ORGANIZATIONS.

    Directory of Open Access Journals (Sweden)

    Maria Lúcia Gili Massi

    2013-06-01

    Full Text Available The objective of this article is to verify whether organizations’ high performance rests on their culture, which adjusts their cultural values, strategy, and external environment. A strong organizational culture has been reported as determinant of organizations’ performance. These studies approach the influence of values guiding and adjusting the organization’s strategic actions regarding its external environment. The bibliographic research showed that there are other variables impacting of organizations’ performance and it was concluded that the objective of this study was partially achieved.

  2. Effects of 12 weeks high-intensity & reduced-volume training in elite athletes

    DEFF Research Database (Denmark)

    Kilen, Anders; Larsson, Tanja Hultengren; Jørgensen, Majke;

    2014-01-01

    It was investigated if high-intensity interval training (HIT) at the expense of total training volume improves performance, maximal oxygen uptake and swimming economy. 41 elite swimmers were randomly allocated to a control (CON) or HIT group. For 12 weeks both groups trained ∼12 h per week. HIT c...

  3. High-intensity erotic visual stimuli de-activate the primary visual cortex in women.

    Science.gov (United States)

    Huynh, Hieu K; Beers, Caroline; Willemsen, Antoon; Lont, Erna; Laan, Ellen; Dierckx, Rudi; Jansen, Monique; Sand, Michael; Weijmar Schultz, Willibrord; Holstege, Gert

    2012-06-01

    The primary visual cortex, Brodmann's area (BA 17), plays a vital role in basic survival mechanisms in humans. In most neuro-imaging studies in which the volunteers have to watch pictures or movies, the primary visual cortex is similarly activated independent of the content of the pictures or movies. However, in case the volunteers perform demanding non-visual tasks, the primary visual cortex becomes de-activated, although the amount of incoming visual sensory information is the same. Do low- and high-intensity erotic movies, compared to neutral movies, produce similar de-activation of the primary visual cortex? Brain activation/de-activation was studied by Positron Emission Tomography scanning of the brains of 12 healthy heterosexual premenopausal women, aged 18-47, who watched neutral, low- and high-intensity erotic film segments. We measured differences in regional cerebral blood flow (rCBF) in the primary visual cortex during watching neutral, low-intensity erotic, and high-intensity erotic film segments. Watching high-intensity erotic, but not low-intensity erotic movies, compared to neutral movies resulted in strong de-activation of the primary (BA 17) and adjoining parts of the secondary visual cortex. The strong de-activation during watching high-intensity erotic film might represent compensation for the increased blood supply in the brain regions involved in sexual arousal, also because high-intensity erotic movies do not require precise scanning of the visual field, because the impact is clear to the observer. © 2012 International Society for Sexual Medicine.

  4. Optimizations for High Performance Network Virtualization

    Institute of Scientific and Technical Information of China (English)

    Fan-Fu Zhou; Ru-Hui Ma; Jian Li; Li-Xia Chen; Wei-Dong Qiu; Hai-Bing Guan

    2016-01-01

    The increasing requirements of intensive interoperaterbility among the distributed nodes desiderate the high performance network connections, owing to the substantial growth of cloud computing and datacenters. Network I/O virtualization aggregates the network resource and separates it into manageable parts for particular servers or devices, which provides effective consolidation and elastic management with high agility, flexibility and scalability as well as reduced cost and cabling. However, both network I/O virtualization aggregation and the increasing network speed incur higher traffic density, which generates a heavy system stress for I/O data moving and I/O event processing. Consequently, many researchers have dedicated to enhancing the system performance and alleviating the system overhead for high performance networking virtualization. This paper first elaborates the mainstreaming I/O virtualization methodologies, including device emulation, split-driver model and hardware assisted model. Then, the paper discusses and compares their specific advantages in addition to performance bottlenecks in practical utilities. This paper mainly focuses on the comprehensive survey of state-of-the-art approaches for performance optimizations and improvements as well as the portability management for network I/O virtualization. The approaches include various novel data delivery schemes, overhead mitigations for interrupt processing and adequate resource allocations for dynamic network states. Finally, we highlight the diversity of I/O virtualization besides the performance improvements in network virtualization infrastructure.

  5. Extremely high-intensity laser interactions with fundamental quantum systems

    CERN Document Server

    Di Piazza, A; Hatsagortsyan, K Z; Keitel, C H

    2011-01-01

    The field of laser-matter interaction traditionally deals with the response of atoms, molecules and plasmas to an external light wave. However, the recent sustained technological progress is opening the possibility of employing intense laser radiation to prompt or substantially influence physical processes beyond atomic-physics energy scales. Available optical laser intensities exceeding $10^{22}\\;\\text{W/cm$^2$}$ can push the fundamental light-electron interaction to the extreme limit where radiation-reaction effects dominate the electron dynamics, can shed light on the structure of the quantum vacuum and can prime the creation of particles like electrons, muons and pions and the corresponding antiparticles. Also, novel sources of intense coherent high-energy photons and laser-based particle colliders can pave the way to nuclear quantum optics and can even allow for potential discovery of new particles beyond the Standard Model. These are the main topics of the present article, which is devoted to a review o...

  6. Impact of High-intensity Intermittent and Moderate-intensity Continuous Exercise on Autonomic Modulation in Young Men.

    Science.gov (United States)

    Cabral-Santos, C; Giacon, T R; Campos, E Z; Gerosa-Neto, J; Rodrigues, B; Vanderlei, L C M; Lira, F S

    2016-06-01

    The aim of this study was to compare heart rate variability (HRV) recovery after two iso-volume (5 km) exercises performed at different intensities. 14 subjects volunteered (25.17±5.08 years; 74.7±6.28 kg; 175±0.05 cm; 59.56±5.15 mL·kg(-1)·min(-1)) and after determination of peak oxygen uptake (VO2Peak) and the speed associated with VO2Peak (sVO2Peak), the subjects completed 2 random experimental trials: high-intensity exercise (HIE - 1:1 at 100% sVO2Peak), and moderate-intensity continuous exercise (MIE - 70% sVO2Peak). HRV and RR intervals were monitored before, during and after the exercise sessions together with, the HRV analysis in the frequency domains (high-frequency - HF: 0.15 to 0.4 Hz and low-frequency - LF: 0.04 to 0.15 Hz components) and the ratio between them (LF/HF). Statistical analysis comparisons between moments and between HIE and MIE were performed using a mixed model. Both exercise sessions modified LFlog, HFlog, and LF/HF (F=16.54, F=19.32 and F=5.17, p<0.05, respectively). A group effect was also found for LFlog (F=23.91, p<0.05), and HFlog (F=57.55, p< 0.05). LF/HF returned to resting value 15 min after MIE exercise and 20 min after HIE exercise. This means that the heavy domain (aerobic and anaerobic threshold) induces dissimilar autonomic modification in physically active subjects. Both HIE and MIE modify HRV, and generally HIE delays parasympathetic autonomic modulation recovery after iso-volume exercise.

  7. High-Performance Polymeric Materials.

    Science.gov (United States)

    1987-12-07

    interactions, Chain packing, Polybenzobisoxazoles Electrical conductivity Polybenzobisthiazoles Ceramic particles Chain flexibility Elastomer reinforcement...structures for the polybenzobisoxazole (PBO) and polybenzobisthiazole (PBT) chains originally synthesized and much studied because of their utility as...high-performance fibers and films. For cts-PBO, trans-PBO. and trans-PBT chains in their coplanar conformations, the band gaps in the axial direction

  8. High performance rolling element bearing

    Science.gov (United States)

    Bursey, Jr., Roger W. (Inventor); Olinger, Jr., John B. (Inventor); Owen, Samuel S. (Inventor); Poole, William E. (Inventor); Haluck, David A. (Inventor)

    1993-01-01

    A high performance rolling element bearing (5) which is particularly suitable for use in a cryogenically cooled environment, comprises a composite cage (45) formed from glass fibers disposed in a solid lubricant matrix of a fluorocarbon polymer. The cage includes inserts (50) formed from a mixture of a soft metal and a solid lubricant such as a fluorocarbon polymer.

  9. High Performance Bulk Thermoelectric Materials

    Energy Technology Data Exchange (ETDEWEB)

    Ren, Zhifeng [Boston College, Chestnut Hill, MA (United States)

    2013-03-31

    Over 13 plus years, we have carried out research on electron pairing symmetry of superconductors, growth and their field emission property studies on carbon nanotubes and semiconducting nanowires, high performance thermoelectric materials and other interesting materials. As a result of the research, we have published 104 papers, have educated six undergraduate students, twenty graduate students, nine postdocs, nine visitors, and one technician.

  10. High performance in software development

    CERN Document Server

    CERN. Geneva; Haapio, Petri; Liukkonen, Juha-Matti

    2015-01-01

    What are the ingredients of high-performing software? Software development, especially for large high-performance systems, is one the most complex tasks mankind has ever tried. Technological change leads to huge opportunities but challenges our old ways of working. Processing large data sets, possibly in real time or with other tight computational constraints, requires an efficient solution architecture. Efficiency requirements span from the distributed storage and large-scale organization of computation and data onto the lowest level of processor and data bus behavior. Integrating performance behavior over these levels is especially important when the computation is resource-bounded, as it is in numerics: physical simulation, machine learning, estimation of statistical models, etc. For example, memory locality and utilization of vector processing are essential for harnessing the computing power of modern processor architectures due to the deep memory hierarchies of modern general-purpose computers. As a r...

  11. H- Ion Sources for High Intensity Proton Drivers

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland Paul; Dudnikov, Vadim

    2015-02-20

    Existing RF Surface Plasma Sources (SPS) for accelerators have specific efficiencies for H+ and H- ion generation around 3 to 5 mA/cm2 per kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) SPS described here was developed to improve H- ion production efficiency, reliability and availability for pulsed operation as used in the ORNL Spallation Neutron Source . At low RF power, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm2 per kW of RF power at 13.56 MHz. Initial cesiation of the SPS was performed by heating cesium chromate cartridges by discharge as was done in the very first versions of the SPS. A small oven to decompose cesium compounds and alloys was developed and tested. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power 1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with 4 kW RF power in the plasma and 250 Gauss longitudinal magnetic field. The ratio of electron current to negative ion current was improved from 30 to 2. Stable generation of H- beam without intensity degradation was demonstrated in the aluminum nitride (AlN) discharge chamber for 32 days at high discharge power in an RF SPS with an external antenna. Some modifications were made to improve the cooling and cesiation stability. The extracted collector current can be increased significantly by optimizing the longitudinal magnetic field in the discharge chamber. While this project demonstrated the advantages of the pulsed version of the SA RF SPS as an upgrade to the ORNL Spallation Neutron Source, it led to a possibility for upgrades to CW machines like the many cyclotrons used for commercial applications. Four appendices contain important details of the work carried out under this grant.

  12. H- Ion Sources for High Intensity Proton Drivers

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland Paul [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Dudnikov, Vadim [Muons, Inc., Batavia, IL (United States)

    2015-02-20

    Existing RF Surface Plasma Sources (SPS) for accelerators have specific efficiencies for H+ and H- ion generation around 3 to 5 mA/cm2 per kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) SPS described here was developed to improve H- ion production efficiency, reliability and availability for pulsed operation as used in the ORNL Spallation Neutron Source . At low RF power, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm2 per kW of RF power at 13.56 MHz. Initial cesiation of the SPS was performed by heating cesium chromate cartridges by discharge as was done in the very first versions of the SPS. A small oven to decompose cesium compounds and alloys was developed and tested. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power 1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with 4 kW RF power in the plasma and 250 Gauss longitudinal magnetic field. The ratio of electron current to negative ion current was improved from 30 to 2. Stable generation of H- beam without intensity degradation was demonstrated in the aluminum nitride (AlN) discharge chamber for 32 days at high discharge power in an RF SPS with an external antenna. Some modifications were made to improve the cooling and cesiation stability. The extracted collector current can be increased significantly by optimizing the longitudinal magnetic field in the discharge chamber. While this project demonstrated the advantages of the pulsed version of the SA RF SPS as an upgrade to the ORNL Spallation Neutron Source, it led to a possibility for upgrades to CW machines like the many cyclotrons used for commercial applications. Four appendices contain important details of the work carried out under this grant.

  13. Beam instrumentation for future high intense hadron accelerators at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Wendt, M.; Hu, M.; Tassotto, G.; Thurman-Keup, R.; Scarpine, V.; Shin, S.; Zagel, J.; /Fermilab

    2008-08-01

    High intensity hadron beams of up to 2 MW beam power are a key element of new proposed experimental facilities at Fermilab. Project X, which includes a SCRF 8 GeV H{sup -} linac, will be the centerpiece of future HEP activities in the neutrino sector. After a short overview of this, and other proposed projects, we present the current status of the beam instrumentation activities at Fermilab with a few examples. With upgrades and improvements they can meet the requirements of the new beam facilities, however design and development of new instruments is needed, as shown by the prototype and conceptual examples in the last section.

  14. Development of High Intensity Beam Emittance Measurement Unit

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Three sets of High Intensity Beam Emittance Measurement Units (HIBEMUs) are being developed at Peking University. They are HIBEMU-2 (slit-wire type, one direction), HIBEMU-3 (Allison scanner type, one direction) and HIBEMU-4 (slit-wire type, two directions). For HIBEMU-2 and HIBEMU-3, more recent work has been done on software redesign in order to measure beam emittance and to draw phase diagram more efficiently and precisely. Software for control and data processing of them were developed in Labveiw environment, trying to improve calculation rationality and to offer user-friendly interface. Mechanical modification was also done for HIBEMU-3, mainly concentrating on the protection of Faraday cups from being overheated by the high intensity beam and also from interference of secondary electrons. This paper will also cover the mechanical structure as well as the software development of HIBEMU-4, which is a two-direction emittance scanner newly designed and manufactured for the high energy beam transport (HEBT) of Peking University Neutron Imaging FaciliTY (PKUNIFTY). At the end of this paper, comparison and analysis of the three HIBEMUs are given to draw forth better design of the future emittance measurement facility.

  15. High Intensity Focused Ultrasound Tumor Therapy System and Its Application

    Science.gov (United States)

    Sun, Fucheng; He, Ye; Li, Rui

    2007-05-01

    At the end of last century, a High Intensity Focused Ultrasound (HIFU) tumor therapy system was successfully developed and manufactured in China, which has been already applied to clinical therapy. This article aims to discuss the HIFU therapy system and its application. Detailed research includes the following: power amplifiers for high-power ultrasound, ultrasound transducers with large apertures, accurate 3-D mechanical drives, a software control system (both high-voltage control and low-voltage control), and the B-mode ultrasonic diagnostic equipment used for treatment monitoring. Research on the dosage of ultrasound required for tumour therapy in multiple human cases has made it possible to relate a dosage formula, presented in this paper, to other significant parameters such as the volume of thermal tumor solidification, the acoustic intensity (I), and the ultrasound emission time (tn). Moreover, the HIFU therapy system can be applied to the clinical treatment of both benign and malignant tumors in the pelvic and abdominal cavity, such as uterine fibroids, liver cancer and pancreatic carcinoma.

  16. REFERENCED TECHNOLOGICAL PERFORMANCES FOR STURGEON FINGERLING BREEDING IN INTENSIVE SYSTEM

    Directory of Open Access Journals (Sweden)

    MARILENA TALPES

    2013-12-01

    Full Text Available Work objective is to present an oversight regarding the modality to rearing the descendents of anadromous sturgeon species, Acipenser stellatus, Acipenser gueldenstaedti and Huso huso, obtained trough artificial reproduction, indicating successively, the production system, its management, alimentation strategy for sturgeon species and technological performances registered by these. Experiments developed during two phases, respectively the post-embryonary one and sapling rearing during of a 168 days period. Registered performances of sturgeon species material were assessed in conformity with specifically biotechnological indicators.

  17. Série de treinamento intervalado de alta intensidade como índice de determinação da tolerância à acidose na predição da performance anaeróbia de natação High intensity interval training series as indices of acidosis tolerance determination in swimming anaerobic performance prediction

    Directory of Open Access Journals (Sweden)

    Rafael Deminice

    2007-06-01

    Full Text Available O objetivo do presente estudo foi determinar a tolerância à acidose através de uma série de nados intervalados de alta intensidade e relacionar com a velocidade de limiar anaeróbio (VLan, concentração de lactato sanguíneo de pico ([Lac]pico, capacidade de trabalho anaeróbio (CTA, freqüência de braçada (fB, comprimento de braçada (CB e índice de braçada (IB na predição da performance de 100m de natação. Dez nadadores realizaram seis nados máximos de 100m no estilo crawl com intervalo de seis minutos. Amostras de sangue foram coletadas cinco minutos após cada nado para posterior análise de lactacidemia ([Lac]. Através da razão entre [Lac] e os respectivos tempos de execução dos seis nados, determinou-se a tolerância à acidose (TA. O número de braçadas realizadas durante os seis esforços foi anotado para determinação da fB, CB, IB. Um nado máximo de 100m foi utilizado como parâmetro de performance (P100 e amostras de sangue foram coletadas para determinação da concentração de lactato sanguíneo de pico ([Lac]pico. Três esforços progressivos de 400m foram realizados para determinação da VLan correspondente à concentração fixa de 3,5mM de lactato. Esforços máximos de 200 e 400m foram realizados para determinação da CTA por regressão linear (coeficiente linear. Os resultados apresentaram significativas correlações (p The aim of the present study was to determine the acidosis tolerance through one high intensity interval swim serie and to relate with anaerobic threshold speed (ATS, blood lactate peak concentration ([Lac]peak, anaerobic work capacity (AWC, stroke rate (SR, stroke length (SL and stroke index (SI in swimming 100 m performance prediction. Ten swimmers performed six maximal swims along 100 m by crawl style with 6 minutes for a rest. Blood samples were taken 5 minutes before each swim for lactate analyses ([Lac]. Through the division of the [Lac] for the time to complete the 6 swims, was

  18. High Performance Tools And Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Collette, M R; Corey, I R; Johnson, J R

    2005-01-24

    This goal of this project was to evaluate the capability and limits of current scientific simulation development tools and technologies with specific focus on their suitability for use with the next generation of scientific parallel applications and High Performance Computing (HPC) platforms. The opinions expressed in this document are those of the authors, and reflect the authors' current understanding and functionality of the many tools investigated. As a deliverable for this effort, we are presenting this report describing our findings along with an associated spreadsheet outlining current capabilities and characteristics of leading and emerging tools in the high performance computing arena. This first chapter summarizes our findings (which are detailed in the other chapters) and presents our conclusions, remarks, and anticipations for the future. In the second chapter, we detail how various teams in our local high performance community utilize HPC tools and technologies, and mention some common concerns they have about them. In the third chapter, we review the platforms currently or potentially available to utilize these tools and technologies on to help in software development. Subsequent chapters attempt to provide an exhaustive overview of the available parallel software development tools and technologies, including their strong and weak points and future concerns. We categorize them as debuggers, memory checkers, performance analysis tools, communication libraries, data visualization programs, and other parallel development aides. The last chapter contains our closing information. Included with this paper at the end is a table of the discussed development tools and their operational environment.

  19. Max Tech and Beyond: High-Intensity Discharge Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Scholand, Michael

    2012-04-01

    High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. With the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's. In HID lamps, light is generated by creating an electric arc between two electrodes in an arc tube. The particles in the arc are partially ionized, making them electrically conductive, and a light-emitting 'plasma' is created. This arc occurs within the arc tube, which for most HID lamps is enclosed within an evacuated outer bulb that thermally isolates and protects the hot arc tube from the surroundings. Unlike a fluorescent lamp that produces visible light through down-converting UV light with phosphors, the arc itself is the light source in an HID lamp, emitting visible radiation that is characteristic of the elements present in the plasma. Thus, the mixture of elements included in the arc tube is one critical factor determining the quality of the light emitted from the lamp, including its correlated color temperature (CCT) and color rendering index (CRI). Similar to fluorescent lamps, HID lamps require a ballast to start and maintain stable

  20. High-Intensity Sweeteners in Alternative Tobacco Products.

    Science.gov (United States)

    Miao, Shida; Beach, Evan S; Sommer, Toby J; Zimmerman, Julie B; Jordt, Sven-Eric

    2016-11-01

    Sweeteners in tobacco products may influence use initiation and reinforcement, with special appeal to adolescents. Recent analytical studies of smokeless tobacco products (snuff, snus, dissolvables) detected flavorants identical to those added to confectionary products such as hard candy and chewing gum. However, these studies did not determine the levels of sweeteners. The objective of the present study was to quantify added sweeteners in smokeless tobacco products, a dissolvable product, electronic cigarette liquids and to compare with sweetener levels in confectionary products. Sweetener content of US-sourced smokeless tobacco, electronic cigarette liquid, and confectionary product samples was analyzed by liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS). All smokeless products contained synthetic high intensity sweeteners, with snus and dissolvables exceeding levels in confectionary products (as much as 25-fold). All snus samples contained sucralose and most also aspartame, but no saccharin. In contrast, all moist snuff samples contained saccharin. The dissolvable sample contained sucralose and sorbitol. Ethyl maltol was the most common sweet-associated component in electronic cigarette liquids. Sweetener content was dependent on product category, with saccharin in moist snuff, an older category, sucralose added at high levels to more recently introduced products (snus, dissolvable) and ethyl maltol in electronic cigarette liquid. The very high sweetener concentrations may be necessary for the consumer to tolerate the otherwise aversive flavors of tobacco ingredients. Regulation of sweetener levels in smokeless tobacco products may be an effective measure to modify product attractiveness, initiation and use patterns. Dissolvables, snus and electronic cigarettes have been promoted as risk-mitigation products due to their relatively low content of nitrosamines and other tobacco toxicants. This study is the first to quantify high

  1. High-Intensity Sweeteners in Alternative Tobacco Products

    Science.gov (United States)

    Miao, Shida; Beach, Evan S.; Sommer, Toby J.; Zimmerman, Julie B.

    2016-01-01

    Introduction: Sweeteners in tobacco products may influence use initiation and reinforcement, with special appeal to adolescents. Recent analytical studies of smokeless tobacco products (snuff, snus, dissolvables) detected flavorants identical to those added to confectionary products such as hard candy and chewing gum. However, these studies did not determine the levels of sweeteners. The objective of the present study was to quantify added sweeteners in smokeless tobacco products, a dissolvable product, electronic cigarette liquids and to compare with sweetener levels in confectionary products. Methods: Sweetener content of US-sourced smokeless tobacco, electronic cigarette liquid, and confectionary product samples was analyzed by liquid chromatography-electrospray ionization–mass spectrometry (LC-ESI-MS). Results: All smokeless products contained synthetic high intensity sweeteners, with snus and dissolvables exceeding levels in confectionary products (as much as 25-fold). All snus samples contained sucralose and most also aspartame, but no saccharin. In contrast, all moist snuff samples contained saccharin. The dissolvable sample contained sucralose and sorbitol. Ethyl maltol was the most common sweet-associated component in electronic cigarette liquids. Discussion: Sweetener content was dependent on product category, with saccharin in moist snuff, an older category, sucralose added at high levels to more recently introduced products (snus, dissolvable) and ethyl maltol in electronic cigarette liquid. The very high sweetener concentrations may be necessary for the consumer to tolerate the otherwise aversive flavors of tobacco ingredients. Regulation of sweetener levels in smokeless tobacco products may be an effective measure to modify product attractiveness, initiation and use patterns. Implications: Dissolvables, snus and electronic cigarettes have been promoted as risk-mitigation products due to their relatively low content of nitrosamines and other tobacco

  2. High-intensity interval training (HIIT for patients with chronic diseases

    Directory of Open Access Journals (Sweden)

    Leanna M. Ross

    2016-06-01

    Full Text Available Exercise training provides physiological benefits for both improving athletic performance and maintaining good health. Different exercise training modalities and strategies exist. Two common exercise strategies are high-intensity interval training (HIIT and moderate-intensity continuous exercise training (MCT. HIIT was first used early in the 20th century and popularized later that century for improving performance of Olympic athletes. The primary premise underlying HIIT is that, compared to energy expenditure-matched MCT, a greater amount of work is performed at a higher intensity during a single exercise session which is achieved by alternating high-intensity exercise intervals with low-intensity exercise or rest intervals. Emerging research suggests that this same training method can provide beneficial effects for patients with a chronic disease and should be included in the comprehensive medical management plan. Accordingly, a major consideration in developing an individual exercise prescription for a patient with a chronic disease is the selection of an appropriate exercise strategy. In order to maximize exercise training benefits, this strategy should be tailored to the individual's need. The focus of this paper is to provide a brief summary of the current literature regarding the use of HIIT to enhance the functional capacity of individuals with cardiovascular, pulmonary, and diabetes diseases.

  3. The effect of high and low exercise intensity periods on a simple memory recognition test

    Institute of Scientific and Technical Information of China (English)

    Ben Rattray; Disa J. Smee

    2016-01-01

    Purpose: The purpose of this study was to investigate the effect of variable intensities on a simple memory recognition task during exercise. Methods: Twenty active participants took part in initial testing, a familiarization trial and then four 60 min cycling interventions in a randomized order. Interventions consisted of no exercise (control), constant exercise at 90%ventilatory threshold (constant) and 2 trials that initially mimicked the constant trial, but then included periods of high (∼90%VO2peak) and low intensities (∼50%VO2peak). Cardiorespiratory measures and capillary blood samples were taken throughout. A short tablet-based cognitive task was completed prior to and during (50 and 55 min into exercise) each intervention. Results: The exercise conditions facilitated response time (p=0.009), although the extent of this effect was not as strong in the variable exercise conditions (p = 0.011–0.089). High intensity exercise periods resulted in some cognitive regression back towards control trial performance. Elevations in cardiorespiratory measures and periods of hypocapnia could not explain changes in cognitive performance. Conclusion: Changes in cognitive performance with variations in exercise intensity are likely to have implications for sport and occupational settings. The timing of cognitive tests to exercise intensity changes as well as use of short cognitive assessments will be important for future work.

  4. High-intensity interval training (HIIT) for patients with chronic diseases

    Institute of Scientific and Technical Information of China (English)

    Leanna M. Ross; Ryan R. Porter; J. Larry Durstine

    2016-01-01

    Exercise training provides physiological benefits for both improving athletic performance and maintaining good health. Different exercise training modalities and strategies exist. Two common exercise strategies are high-intensity interval training (HIIT) and moderate-intensity continuous exercise training (MCT). HIIT was first used early in the 20th century and popularized later that century for improving performance of Olympic athletes. The primary premise underlying HIIT is that, compared to energy expenditure-matched MCT, a greater amount of work is performed at a higher intensity during a single exercise session which is achieved by alternating high-intensity exercise intervals with low-intensity exercise or rest intervals. Emerging research suggests that this same training method can provide beneficial effects for patients with a chronic disease and should be included in the comprehensive medical management plan. Accordingly, a major consideration in developing an individual exercise prescription for a patient with a chronic disease is the selection of an appropriate exercise strategy. In order to maximize exercise training benefits, this strategy should be tailored to the individual’s need. The focus of this paper is to provide a brief summary of the current literature regarding the use of HIIT to enhance the functional capacity of individuals with cardiovascular, pulmonary, and diabetes diseases.

  5. Longitudinal tracking studies for a high intensity proton synchrotron

    Energy Technology Data Exchange (ETDEWEB)

    Lessner, E.; Cho, Y.; Harkay, K.; Symon, K. [Argonne National Laboratory, 9700 Cass Ave., Argonne, Illinois 60439 (United States)

    1996-06-01

    Results from longitudinal tracking studies for a high intensity proton synchrotron designed for a 1-MW spallation source are presented. The machine delivers a proton beam of 0.5 mA time-averaged current at a repetition rate of 30 Hz. The accelerator is designed to have radiation levels that allow hands-on-maintenance. However, the high beam intensity causes strong space charge fields whose effects may lead to particle loss and longitudinal instabilities. The space charge fields modify the particle distribution, distort the stable bucket area and reduce the rf linear restoring force. Tracking simulations were conducted to analyze the space charge effects on the dynamics of the injection and acceleration processes and means to circumvent them. The tracking studies led to the establishment of the injected beam parameters and rf voltage program that minimized beam loss and longitudinal instabilities. Similar studies for a 10-GeV synchrotron that uses the 2-GeV synchrotron as its injector are also discussed. {copyright} {ital 1996 American Institute of Physics.}

  6. Formation of a high intensity low energy positron string

    Science.gov (United States)

    Donets, E. D.; Donets, E. E.; Syresin, E. M.; Itahashi, T.; Dubinov, A. E.

    2004-05-01

    The possibility of a high intensity low energy positron beam production is discussed. The proposed Positron String Trap (PST) is based on the principles and technology of the Electron String Ion Source (ESIS) developed in JINR during the last decade. A linear version of ESIS has been used successfully for the production of intense highly charged ion beams of various elements. Now the Tubular Electron String Ion Source (TESIS) concept is under study and this opens really new promising possibilities in physics and technology. In this report, we discuss the application of the tubular-type trap for the storage of positrons cooled to the cryogenic temperatures of 0.05 meV. It is intended that the positron flux at the energy of 1-5 eV, produced by the external source, is injected into the Tubular Positron Trap which has a similar construction as the TESIS. Then the low energy positrons are captured in the PST Penning trap and are cooled down because of their synchrotron radiation in the strong (5-10 T) applied magnetic field. It is expected that the proposed PST should permit storing and cooling to cryogenic temperature of up to 5×109 positrons. The accumulated cooled positrons can be used further for various physics applications, for example, antihydrogen production.

  7. Use of High Intensity Focused Ultrasound for Treating Malignant Tumors

    Institute of Scientific and Technical Information of China (English)

    WenzhiChen; ZhibiaoWang; FengWu; JinBai; HuiZhu; JianzhongZou; KequanLi; FanglinXie; ZhilongWang

    2004-01-01

    OBJECTIVE To investigate the efficacy and side effects of high intensity focused ultrasound(HIFU) in the treatment of malignant solid tumors. METHODS Thirty patients who refused surgery and/or were refractory to chemotherapy were treated by HIFU alone, with the efficacy and side effects monitored as follows: observation of vital organ signs; functional assay of important organs; imaging examinations including: digital subtraction angiography (DSA), CT, MRI, single photon emission computed tomography (SPECT), large core needle biopsy, complications and metastasis. RESULTS After HIFU therapy, the vital signs remained stable and the functions of the heart, lung, kidney and liver were also normal. DSA images showed that small or larger arteries were not damaged. After a follow-up of 10-38 months(mean 23.1 months), 26 patients(87%) were alive. The volume of the tumor underwent complete regression in 10 patients. Shrinkage of the tumor volume ≥50% was observed in 13 patients. Eight of 13 patients were examined by large core needle biopsy, all showing necrosis and/or fibrosis though 3 patients(10%) had local recurrence. Two of these were retreated again by HIFU and the locally recurrent tumors were controlled. New metastases developed in 5 patients after H IFU. Two patients suffered from peripheral nerve injuriy and they have recovered during the follow-up. One patient developed skin injury. CONCLUSION High intensity focused ultrasound is effective and safe in the treatment of malignant solid tumors.

  8. The high intensity solar cell - Key to low cost photovoltaic power

    Science.gov (United States)

    Sater, B. L.; Goradia, C.

    1975-01-01

    This paper discusses the problems associated with conventional solar cells at high intensities and presents the design considerations and performance characteristics of the 'high intensity' (HI) solar cell which appears to eliminate the major problems. Test data obtained at greater than 250 AM1 suns gave a peak output power density of 2 W per sq cm at an efficiency exceeding 6% with an unoptimized cell operating at over 100 C. It appears that operation at 1000 AM1 suns at efficiencies greater than 10% is possible. At 1000 AM1 suns and 10% efficiency, the HI cell manufacturing cost is estimated to be $0.25/watt, with multi-megawatt annual production capability already existing within the industrial sector. A high intensity solar system was also analyzed to determine its cost effectiveness and to assess the benefits of further improving HI cell efficiency.

  9. Changes in satellite cells in human skeletal muscle after a single bout of high intensity exercise

    DEFF Research Database (Denmark)

    Crameri, Regina M; Langberg, Henning; Magnusson, Peter

    2004-01-01

    desmin or dystrophin, were not observed, and hence did not appear to induce the expression of either N-CAM or FA1. We therefore propose that satellite cells can be induced to re-enter the cell growth cycle after a single bout of unaccustomed high intensity exercise. However, a single bout of exercise......No studies to date have reported activation of satellite cells in vivo in human muscle after a single bout of high intensity exercise. In this investigation, eight individuals performed a single bout of high intensity exercise with one leg, the contralateral leg being the control. A significant...... increase in mononuclear cells staining for the neural cell adhesion molecule (N-CAM) and fetal antigen 1 (FA1) were observed within the exercised human vastus lateralis muscle on days 4 and 8 post exercise. In addition, a significant increase in the concentration of the FA1 protein was determined...

  10. Max Tech and Beyond: High-Intensity Discharge Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Scholand, Michael

    2012-04-01

    High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. With the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's. In HID lamps, light is generated by creating an electric arc between two electrodes in an arc tube. The particles in the arc are partially ionized, making them electrically conductive, and a light-emitting 'plasma' is created. This arc occurs within the arc tube, which for most HID lamps is enclosed within an evacuated outer bulb that thermally isolates and protects the hot arc tube from the surroundings. Unlike a fluorescent lamp that produces visible light through down-converting UV light with phosphors, the arc itself is the light source in an HID lamp, emitting visible radiation that is characteristic of the elements present in the plasma. Thus, the mixture of elements included in the arc tube is one critical factor determining the quality of the light emitted from the lamp, including its correlated color temperature (CCT) and color rendering index (CRI). Similar to fluorescent lamps, HID lamps require a ballast to start and maintain stable

  11. Impact of the dipole-moment representation on the intensity of high overtones

    Science.gov (United States)

    Medvedev, Emile S.; Meshkov, Vladimir V.; Stolyarov, Andrey V.; Ushakov, Vladimir G.; Gordon, Iouli E.

    2016-12-01

    Calculating intensities of ro-vibrational transitions is particularly challenging for transitions from a given vibrational state to all upper states up to the dissociation limit because their probabilities decrease exponentially with increasing Δn , the change in the vibrational quantum number. The experimental intensities available for low- Δn values are well reproduced by a variety of models but the models can greatly diverge in predicting the intensities of unobserved high-overtone transitions, the divergence rapidly increasing with the overtone number. In this paper, we investigate the impact of the dipole-moment function (DMF) representation on the high-overtone intensity simulation of the CO molecule. We tested various DMF forms including pointwise representation combined with cubic-spline interpolation, power and trigonometric expansions, and Padé approximants. Numerical calculations were performed with the highly accurate empirical potential-energy function (PEF) of Coxon and Hajigeorgiou (2004) using quadruple-precision arithmetic. Most calculated intensities fall off in the entire range of transitions according to the Normal Intensity Distribution Law (NIDL) (Medvedev, 2012). The slope of the NIDL trend line varies little between different analytical DMFs for a given PEF since the slope is basically associated with the PEF. Based on the NIDL, the limits within which the simulated intensities fall off up to the dissociation limit can be established. We claim that DMFs represented by analytical functions yield best results for all transitions. The pointwise functions (interpolated, in particular, by the conventional cubic splines) result in an unphysical flattening of the intensities at high- Δn transitions, Δn > 7 for CO.

  12. Efficacy of high intensity atorvastatin versus moderate intensity atorvastatin for acute coronary syndrome patients with diabetes mellitus.

    Science.gov (United States)

    Liu, Zhi; Xu, Yueqiao; Hao, Hengjian; Yin, Chunlin; Xu, Ji; Li, Jing; Wang, Yanling; Xu, Dong

    2016-11-01

    To investigate whether more benefits can be achieved through high intensity atorvastatin compared with moderate intensity atorvastatin in acute coronary syndrome (ACS) patients with diabetes mellitus (DM). This was a randomized controlled trail. Total 591 ACS patients with DM who underwent percutaneous coronary intervention were enrolled, 297 in high intensity atorvastatin group (40mg/day) and 294 in moderate intensity atorvastatin group (20mg/day). The primary end point was one-year incidence of major adverse cardiovascular events (MACE, including cardiovascular death, spontaneous myocardial infarction, unplanned revascularization). Cox proportional hazard regression models were used to analyze the association between clinical endpoints and atorvastatin treatment. At the end of one-year, low-density lipoprotein cholesterol level was lower in high intensity group than in moderate group (1.6±0.6 vs 1.8±0.6, p=0.041). MACE in high intensity group decreased 44.5% than moderate group (8.4% vs. 14.6%, p=0.018). The adjusted hazard ratio (HR) for MACE in patients with atorvastatin 40mg/d was lower compared to patients with atorvastatin 20mg/d (HR [95% CI] 0.61 [0.36 to 0.91], p=0.026). The rates of adverse events were no significantly different between the two groups. For ACS patients with DM, high intensity atorvastatin induced better long-term outcomes compared with moderate intensity. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Ultra-High Intensity Magnetic Field Generation in Dense Plasma

    Energy Technology Data Exchange (ETDEWEB)

    Fisch, Nathaniel J. [Princeton Univ., NJ (United States)

    2014-01-08

    The main objective of this grant proposal was to explore the efficient generation of intense currents. Whereas the efficient generation of electric current in low-­energy-­density plasma has occupied the attention of the magnetic fusion community for several decades, scant attention has been paid to carrying over to high-­energy-­density plasma the ideas for steady-­state current drive developed for low-­energy-­density plasma, or, for that matter, to inventing new methodologies for generating electric current in high-­energy-­density plasma. What we proposed to do was to identify new mechanisms to accomplish current generation, and to assess the operation, physics, and engineering basis of new forms of current drive in regimes appropriate for new fusion concepts.

  14. Generation And Measurement Of High Contrast Ultrashort Intense Laser Pulses

    CERN Document Server

    Konoplev, O A

    2000-01-01

    In this thesis, the generation and measurement of high contrast, intense, ultrashort pulses have been studied. Various factors affecting the contrast and pulse shape of ultrashort light pulses from a chirped pulse amplification (CPA) laser system are identified. The level of contrast resulting from influence of these factors is estimated. Methods for improving and controlling the pulse shape and increasing the contrast are discussed. Ultrahigh contrast, 1-ps pulses were generated from a CPA system with no temporal structure up to eleven orders of magnitude. This is eight orders of magnitude higher contrast than the original pulse. This contrast boost was achieved using two techniques. One is the optical pulse cleaning based on the nonlinear birefringence of the chirping fiber and applied to the pulses before amplification. The other is the fast saturable absorber. The fast saturable absorber was placed after amplification and compression of the pulse. The measurements of high-contrast, ultrashort pulse with h...

  15. Ultra-High Intensity Magnetic Field Generation in Dense Plasma

    Energy Technology Data Exchange (ETDEWEB)

    Fisch, Nathaniel J

    2014-01-08

    I. Grant Objective The main objective of this grant proposal was to explore the efficient generation of intense currents. Whereasthefficient generation of electric current in low-­energy-­density plasma has occupied the attention of the magnetic fusion community for several decades, scant attention has been paid to carrying over to high-­energy-­density plasma the ideas for steady-­state current drive developed for low-­energy-­density plasma, or, for that matter, to inventing new methodologies for generating electric current in high-­energy-­density plasma. What we proposed to do was to identify new mechanisms to accomplish current generation, and to assess the operation, physics, and engineering basis of new forms of current drive in regimes appropriate for new fusion concepts.

  16. High Efficiency, High Performance Clothes Dryer

    Energy Technology Data Exchange (ETDEWEB)

    Peter Pescatore; Phil Carbone

    2005-03-31

    This program covered the development of two separate products; an electric heat pump clothes dryer and a modulating gas dryer. These development efforts were independent of one another and are presented in this report in two separate volumes. Volume 1 details the Heat Pump Dryer Development while Volume 2 details the Modulating Gas Dryer Development. In both product development efforts, the intent was to develop high efficiency, high performance designs that would be attractive to US consumers. Working with Whirlpool Corporation as our commercial partner, TIAX applied this approach of satisfying consumer needs throughout the Product Development Process for both dryer designs. Heat pump clothes dryers have been in existence for years, especially in Europe, but have not been able to penetrate the market. This has been especially true in the US market where no volume production heat pump dryers are available. The issue has typically been around two key areas: cost and performance. Cost is a given in that a heat pump clothes dryer has numerous additional components associated with it. While heat pump dryers have been able to achieve significant energy savings compared to standard electric resistance dryers (over 50% in some cases), designs to date have been hampered by excessively long dry times, a major market driver in the US. The development work done on the heat pump dryer over the course of this program led to a demonstration dryer that delivered the following performance characteristics: (1) 40-50% energy savings on large loads with 35 F lower fabric temperatures and similar dry times; (2) 10-30 F reduction in fabric temperature for delicate loads with up to 50% energy savings and 30-40% time savings; (3) Improved fabric temperature uniformity; and (4) Robust performance across a range of vent restrictions. For the gas dryer development, the concept developed was one of modulating the gas flow to the dryer throughout the dry cycle. Through heat modulation in a

  17. High Efficiency, High Performance Clothes Dryer

    Energy Technology Data Exchange (ETDEWEB)

    Peter Pescatore; Phil Carbone

    2005-03-31

    This program covered the development of two separate products; an electric heat pump clothes dryer and a modulating gas dryer. These development efforts were independent of one another and are presented in this report in two separate volumes. Volume 1 details the Heat Pump Dryer Development while Volume 2 details the Modulating Gas Dryer Development. In both product development efforts, the intent was to develop high efficiency, high performance designs that would be attractive to US consumers. Working with Whirlpool Corporation as our commercial partner, TIAX applied this approach of satisfying consumer needs throughout the Product Development Process for both dryer designs. Heat pump clothes dryers have been in existence for years, especially in Europe, but have not been able to penetrate the market. This has been especially true in the US market where no volume production heat pump dryers are available. The issue has typically been around two key areas: cost and performance. Cost is a given in that a heat pump clothes dryer has numerous additional components associated with it. While heat pump dryers have been able to achieve significant energy savings compared to standard electric resistance dryers (over 50% in some cases), designs to date have been hampered by excessively long dry times, a major market driver in the US. The development work done on the heat pump dryer over the course of this program led to a demonstration dryer that delivered the following performance characteristics: (1) 40-50% energy savings on large loads with 35 F lower fabric temperatures and similar dry times; (2) 10-30 F reduction in fabric temperature for delicate loads with up to 50% energy savings and 30-40% time savings; (3) Improved fabric temperature uniformity; and (4) Robust performance across a range of vent restrictions. For the gas dryer development, the concept developed was one of modulating the gas flow to the dryer throughout the dry cycle. Through heat modulation in a

  18. Toward high performance graphene fibers.

    Science.gov (United States)

    Chen, Li; He, Yuling; Chai, Songgang; Qiang, Hong; Chen, Feng; Fu, Qiang

    2013-07-07

    Two-dimensional graphene and graphene-based materials have attracted tremendous interest, hence much attention has been drawn to exploring and applying their exceptional characteristics and properties. Integration of graphene sheets into macroscopic fibers is a very important way for their application and has received increasing interest. In this study, neat and macroscopic graphene fibers were continuously spun from graphene oxide (GO) suspensions followed by chemical reduction. By varying wet-spinning conditions, a series of graphene fibers were prepared, then, the structural features, mechanical and electrical performances of the fibers were investigated. We found the orientation of graphene sheets, the interaction between inter-fiber graphene sheets and the defects in the fibers have a pronounced effect on the properties of the fibers. Graphene fibers with excellent mechanical and electrical properties will yield great advances in high-tech applications. These findings provide guidance for the future production of high performance graphene fibers.

  19. Neo4j high performance

    CERN Document Server

    Raj, Sonal

    2015-01-01

    If you are a professional or enthusiast who has a basic understanding of graphs or has basic knowledge of Neo4j operations, this is the book for you. Although it is targeted at an advanced user base, this book can be used by beginners as it touches upon the basics. So, if you are passionate about taming complex data with the help of graphs and building high performance applications, you will be able to get valuable insights from this book.

  20. Is moderate intensity exercise training combined with high intensity interval training more effective at improving cardiorespiratory fitness than moderate intensity exercise training alone?

    Science.gov (United States)

    Roxburgh, Brendon H; Nolan, Paul B; Weatherwax, Ryan M; Dalleck, Lance C

    2014-09-01

    The purpose of this study was to compare the effectiveness of either continuous moderate intensity exercise training (CMIET) alone vs. CMIET combined with a single weekly bout of high intensity interval training (HIIT) on cardiorespiratory fitness. Twenty nine sedentary participants (36.3 ± 6.9 yrs) at moderate risk of cardiovascular disease were recruited for 12 weeks of exercise training on a treadmill and cycle ergometer. Participants were randomised into three groups: CMIET + HIIT (n = 7; 8-12 x 60 sec at 100% VO2max, 150 sec active recovery), CMIET (n = 6; 30 min at 45-60% oxygen consumption reserve (VO2R)) and a sedentary control group (n = 7). Participants in the CMIET + HIIT group performed a single weekly bout of HIIT and four weekly sessions of CMIET, whilst the CMIET group performed five weekly CMIET sessions. Probabilistic magnitude-based inferences were determined to assess the likelihood that the true value of the effect represents substantial change. Relative VO2max increased by 10.1% (benefit possible relative to control) in in the CMIET + HIIT group (32.7 ± 9.2 to 36.0 ± 11.5 mL·kg(-1)·min(-1)) and 3.9% (benefit possible relative to control) in the CMIET group (33.2 ± 4.0 to 34.5 ± 6.1 mL·kg(-1)·min(-1)), whilst there was a 5.7% decrease in the control group (30.0 ± 4.6 to 28.3 ± 6.5 mL·kg(-1)·min(-1)). It was 'unclear' if a clinically significant difference existed between the effect of CMIET + HIIT and CMIET on the change in VO2max. Both exercising groups showed clinically meaningful improvements in VO2max. Nevertheless, it remains 'unclear' whether one type of exercise training regimen elicits a superior improvement in cardiorespiratory fitness relative to its counterpart. Key PointsBoth continuous moderate intensity exercise training (CMIET) alone and CMIET combined with a single weekly bout of high intensity interval training (CMIET + HIIT) elicit 'possibly beneficial' clinically meaningful improvements in cardiorespiratory

  1. High-intensity interval versus moderate-intensity continuous training: Superior metabolic benefits in diet-induced obesity mice.

    Science.gov (United States)

    Wang, Ningning; Liu, Yang; Ma, Yanan; Wen, Deliang

    2017-08-23

    Exercise is beneficial in obesity, however, the debate about the value of high-intensity interval training (HIIT) vs. moderate-intensity continuous training (MICT) has been long lasting. Therefore, here we have compared the possible beneficial effects of two different exercise training regimes in a mouse model of diet-induced obesity (DIO). Following 7wk. on high fat diet (HFD), ten-week-old male ICR mice (n=30) were assigned to HIIT, distance-matched MICT or remained sedentary for the next 8 constitutive weeks while maintaining the dietary treatments. Age-matched sedentary mice with standard diet were used as a control (n=10). Exercise was performed on a motorized treadmill for 5days a week. Both modes of exercise ameliorated adiposity and related metabolic dysfunction induced by HFD and sedentary lifestyle, while mice following HIIT exhibited significantly lower body weight, percentage of fat mass and smaller adipocyte size. HIIT was more favorable in preventing liver lipid accumulation by restoring mRNA levels of genes involved in hepatic lipogenesis (SREBP1, ACC1, FAS) and β-oxidation (PPARα, CPT1a, HAD). In addition, HIIT was more efficient in mitigating adipose tissue inflammation and insulin insensitivity, partly dependent on abrogating phosphorylation of JNK/IRS1 (Ser307) pathway. Moreover, only HIIT led to pronounced beige adipocyte recruitment in inguinal subcutaneous adipose tissue. We conclude that HIIT contribute a more favorable regulation of metabolic dysfunctions in DIO mice compared with MICT. Copyright © 2017. Published by Elsevier Inc.

  2. Relativistic electron mirrors from high intensity laser nanofoil interactions

    Energy Technology Data Exchange (ETDEWEB)

    Kiefer, Daniel

    2012-12-21

    The reflection of a laser pulse from a mirror moving close to the speed of light could in principle create an X-ray pulse with unprecedented high brightness owing to the increase in photon energy and accompanying temporal compression by a factor of 4γ{sup 2}, where γ is the Lorentz factor of the mirror. While this scheme is theoretically intriguingly simple and was first discussed by A. Einstein more than a century ago, the generation of a relativistic structure which acts as a mirror is demanding in many different aspects. Recently, the interaction of a high intensity laser pulse with a nanometer thin foil has raised great interest as it promises the creation of a dense, attosecond short, relativistic electron bunch capable of forming a mirror structure that scatters counter-propagating light coherently and shifts its frequency to higher photon energies. However, so far, this novel concept has been discussed only in theoretical studies using highly idealized interaction parameters. This thesis investigates the generation of a relativistic electron mirror from a nanometer foil with current state-of-the-art high intensity laser pulses and demonstrates for the first time the reflection from those structures in an experiment. To achieve this result, the electron acceleration from high intensity laser nanometer foil interactions was studied in a series of experiments using three inherently different high power laser systems and free-standing foils as thin as 3nm. A drastic increase in the electron energies was observed when reducing the target thickness from the micrometer to the nanometer scale. Quasi-monoenergetic electron beams were measured for the first time from ultrathin (≤5nm) foils, reaching energies up to ∝35MeV. The acceleration process was studied in simulations well-adapted to the experiments, indicating the transition from plasma to free electron dynamics as the target thickness is reduced to the few nanometer range. The experience gained from those

  3. Outcomes of exertional rhabdomyolysis following high-intensity resistance training.

    Science.gov (United States)

    Huynh, A; Leong, K; Jones, N; Crump, N; Russell, D; Anderson, M; Steinfort, D; Johnson, D F

    2016-05-01

    High-intensity resistance training (HIRT) programmes are increasingly popular amongst personal trainers and those attending gymnasiums. We report the experience of exertional rhabdomyolysis (ER) at two tertiary hospitals in Melbourne, Australia. To compare the clinical outcomes of ER with other causes of rhabdomyolysis. Retrospective cross-sectional study of patients presenting with a serum creatine kinase (CK) of greater than 25 000 units/L from 1 September 2013 to 31 August 2014 at two tertiary referral hospitals in Melbourne, Australia. Records were examined to identify care measures implemented during hospital stay, clinical outcomes during admission and on subsequent follow up. Thirty four cases of rhabdomyolysis with a CK of greater than 25 000 units/L (normal range: 20-180 units/L) were identified during the 12-month study period. Twelve of the 34 cases (35%) had ER with 10 of 12 related to HIRT. No acute kidney injury, intensive care admission or death were seen among those with ER. All cases were managed conservatively, with 11 admitted and 9 receiving intravenous fluids only. In contrast, patients with rhabdomyolysis from other causes experienced significantly higher rates of intensive care admission (64%, P = 0.0002), acute kidney injury (82%, P = 0.0001) and death (27%, P = 0.069). ER resulting from HIRT appears to have a benign course compared with rhabdomyolysis of other aetiologies in patients with a serum CK greater than 25 000 units/L. Conservative management of ER appears to be adequate, although this requires confirmation in future prospective studies. © 2016 Royal Australasian College of Physicians.

  4. Effects of exercise intensity on spatial memory performance and hippocampal synaptic plasticity in transient brain ischemic rats.

    Directory of Open Access Journals (Sweden)

    Pei-Cheng Shih

    Full Text Available Memory impairment is commonly noted in stroke survivors, and can lead to delay of functional recovery. Exercise has been proved to improve memory in adult healthy subjects. Such beneficial effects are often suggested to relate to hippocampal synaptic plasticity, which is important for memory processing. Previous evidence showed that in normal rats, low intensity exercise can improve synaptic plasticity better than high intensity exercise. However, the effects of exercise intensities on hippocampal synaptic plasticity and spatial memory after brain ischemia remain unclear. In this study, we investigated such effects in brain ischemic rats. The middle cerebral artery occlusion (MCAO procedure was used to induce brain ischemia. After the MCAO procedure, rats were randomly assigned to sedentary (Sed, low-intensity exercise (Low-Ex, or high-intensity exercise (High-Ex group. Treadmill training began from the second day post MCAO procedure, 30 min/day for 14 consecutive days for the exercise groups. The Low-Ex group was trained at the speed of 8 m/min, while the High-Ex group at the speed of 20 m/min. The spatial memory, hippocampal brain-derived neurotrophic factor (BDNF, synapsin-I, postsynaptic density protein 95 (PSD-95, and dendritic structures were examined to document the effects. Serum corticosterone level was also quantified as stress marker. Our results showed the Low-Ex group, but not the High-Ex group, demonstrated better spatial memory performance than the Sed group. Dendritic complexity and the levels of BDNF and PSD-95 increased significantly only in the Low-Ex group as compared with the Sed group in bilateral hippocampus. Notably, increased level of corticosterone was found in the High-Ex group, implicating higher stress response. In conclusion, after brain ischemia, low intensity exercise may result in better synaptic plasticity and spatial memory performance than high intensity exercise; therefore, the intensity is suggested to be

  5. Application of High Intensity THz Pulses for Gas High Harmonic Generation

    CERN Document Server

    Balogh, Emeric; Hebling, János; Dombi, Péter; Farkas, Győző; Varjú, Katalin

    2013-01-01

    The main effects of an intense THz pulse on gas high harmonic generation are studied via trajectory analysis on the single atom level. Spectral and temporal modifications to the generated radiation are highlighted.

  6. Personalized Metabolomics for Predicting Glucose Tolerance Changes in Sedentary Women After High-Intensity Interval Training

    OpenAIRE

    Kuehnbaum, Naomi L.; Gillen, Jenna B.; Gibala, Martin J.; Britz-McKibbin, Philip

    2014-01-01

    High-intensity interval training (HIIT) offers a practical approach for enhancing cardiorespiratory fitness, however its role in improving glucose regulation among sedentary yet normoglycemic women remains unclear. Herein, multi-segment injection capillary electrophoresis-mass spectrometry is used as a high-throughput platform in metabolomics to assess dynamic responses of overweight/obese women (BMI > 25, n = 11) to standardized oral glucose tolerance tests (OGTTs) performed before and after...

  7. High Intensity Interval Training Leads to Greater Improvements in Acute Heart Rate Recovery and Anaerobic Power as High Volume Low Intensity Training

    Directory of Open Access Journals (Sweden)

    Thomas L. Stöggl

    2017-08-01

    Full Text Available The purpose of the current study was to explore if training regimes utilizing diverse training intensity distributions result in different responses on neuromuscular status, anaerobic capacity/power and acute heart rate recovery (HRR in well-trained endurance athletes.Methods: Thirty-six male (n = 33 and female (n = 3 runners, cyclists, triathletes and cross-country skiers [peak oxygen uptake: (VO2peak: 61.9 ± 8.0 mL·kg−1·min−1] were randomly assigned to one of three groups (blocked high intensity interval training HIIT; polarized training POL; high volume low intensity oriented control group CG/HVLIT applying no HIIT. A maximal anaerobic running/cycling test (MART/MACT was performed prior to and following a 9-week training period.Results: Only the HIIT group achieved improvements in peak power/velocity (+6.4%, P < 0.001 and peak lactate (P = 0.001 during the MART/MACT, while, unexpectedly, in none of the groups the performance at the established lactate concentrations (4, 6, 10 mmol·L−1 was changed (P > 0.05. Acute HRR was improved in HIIT (11.2%, P = 0.002 and POL (7.9%, P = 0.023 with no change in the HVLIT oriented control group.Conclusion: Only a training regime that includes a significant amount of HIIT improves the neuromuscular status, anaerobic power and the acute HRR in well-trained endurance athletes. A training regime that followed more a low and moderate intensity oriented model (CG/HVLIT had no effect on any performance or HRR outcomes.

  8. Effects of high-intensity interval training on the VO2 response during severe exercise.

    Science.gov (United States)

    Duffield, Rob; Edge, Johann; Bishop, David

    2006-06-01

    This study examined the effect of high-intensity interval training on the VO2 response during severe, constant-load exercise. Prior to, and following training, 10 females (V O2 peak 37.4+/-6.0 mL kg-1 min-1) performed a graded exercise test to determine VO2 peak and lactate threshold (LT) and a 6 min cycle test (CT) at the pre-training VO2 peak intensity. Training involved high-intensity intervals (2 min work, 1 min rest) performed 3x week for 8 weeks. Breath-by-breath data from 0 to 6 min during the CT were smoothed using 5s averages and fit to a bi-exponential model starting from 20s. Training resulted in significant improvements in VO2 max (2.34+/-0.37-2.78+/-0.30 L min-1), power at VO2 max (170+/-26-204+/-25 W) and power at LT (113+/-17-136+/-20 W) (pVO2 response showed a significant increase in the amplitude of the primary phase (A1) (1396+/-103-1695+/-100 mL min-1; pVO2 (VO2 EE), with no difference (p>0.05) in the time constants of either phase or the amplitude of the slow component (318+/-67-380+/-48 mL; p=0.15). In conjunction, accumulated oxygen deficit (AOD) (43.7+/-9.8-17.2+/-2.8 mL O2 eq kg-1) and anaerobic contribution to the CT (19.4+/-4.4-7.2+/-1.2%) were significantly reduced. In contrast to previous moderate-intensity research, a high-intensity interval training program increased A1 and VO2 EE for the same absolute exercise intensity, decreasing the AOD during a severe-intensity CT.

  9. Semicircular Canal Pressure Changes During High-intensity Acoustic Stimulation.

    Science.gov (United States)

    Maxwell, Anne K; Banakis Hartl, Renee M; Greene, Nathaniel T; Benichoux, Victor; Mattingly, Jameson K; Cass, Stephen P; Tollin, Daniel J

    2017-08-01

    Acoustic stimulation generates measurable sound pressure levels in the semicircular canals. High-intensity acoustic stimuli can cause hearing loss and balance disruptions. To examine the propagation of acoustic stimuli to the vestibular end-organs, we simultaneously measured fluid pressure in the cochlea and semicircular canals during both air- and bone-conducted sound presentation. Five full-cephalic human cadaveric heads were prepared bilaterally with a mastoidectomy and extended facial recess. Vestibular pressures were measured within the superior, lateral, and posterior semicircular canals, and referenced to intracochlear pressure within the scala vestibuli with fiber-optic pressure probes. Pressures were measured concurrently with laser Doppler vibrometry measurements of stapes velocity during stimulation with both air- and bone-conduction. Stimuli were pure tones between 100 Hz and 14 kHz presented with custom closed-field loudspeakers for air-conducted sounds and via commercially available bone-anchored device for bone-conducted sounds. Pressures recorded in the superior, lateral, and posterior semicircular canals in response to sound stimulation were equal to or greater in magnitude than those recorded in the scala vestibuli (up to 20 dB higher). The pressure magnitudes varied across canals in a frequency-dependent manner. High sound pressure levels were recorded in the semicircular canals with sound stimulation, suggesting that similar acoustical energy is transmitted to the semicircular canals and the cochlea. Since these intralabyrinthine pressures exceed intracochlear pressure levels, our results suggest that the vestibular end-organs may also be at risk for injury during exposure to high-intensity acoustic stimuli known to cause trauma in the auditory system.

  10. Proceedings of the third ICFA mini-workshop on high intensity, high brightness hadron accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Roser, T.

    1997-11-01

    The third mini-workshop on high intensity, high brightness hadron accelerators was held at Brookhaven National Laboratory on May 7-9, 1997 and had about 30 participants. The workshop focussed on rf and longitudinal dynamics issues relevant to intense and/or bright hadron synchrotrons. A plenary session was followed by four sessions on particular topics. This document contains copies of the viewgraphs used as well as summaries written by the session chairs.

  11. Proceedings of the third ICFA mini-workshop on high intensity, high brightness hadron accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Roser, T.

    1997-11-01

    The third mini-workshop on high intensity, high brightness hadron accelerators was held at Brookhaven National Laboratory on May 7-9, 1997 and had about 30 participants. The workshop focussed on rf and longitudinal dynamics issues relevant to intense and/or bright hadron synchrotrons. A plenary session was followed by four sessions on particular topics. This document contains copies of the viewgraphs used as well as summaries written by the session chairs.

  12. Blood coagulation using High Intensity Focused Ultrasound (HIFU)

    Science.gov (United States)

    Nguyen, Phuc V.; Oh, Junghwan; Kang, Hyun Wook

    2014-03-01

    High Intensity Focused Ultrasound (HIFU) technology provides a feasible method of achieving thermal coagulation during surgical procedures. One of the potential clinical benefits of HIFU can induce immediate hemostasis without suturing. The objective of this study was to investigate the efficiency of a HIFU system for blood coagulation on severe vascular injury. ngHIFU treatment was implemented immediately after bleeding in artery. The ultrasound probe was made of piezoelectric material, generating a central frequency of 2.0 MHz as well as an ellipsoidal focal spot of 2 mm in lateral dimension and 10 mm in axial dimension. Acoustic coagulation was employed on a perfused chicken artery model in vitro. A surgical incision (1 to 2 mm long) was made with a scapel on the arterial wall, and heparinized autologous blood was made to leak out from the incision with a syringe pump. A total of 5 femoral artery incisions was treated with the HIFU beam. The intensity of 4500 W/cm2 at the focus was applied for all treatments. Complete hemostasis was achieved in all treatments, along with the treatment times of 25 to 50 seconds. The estimated intraoperative blood loss was from 2 to 5 mL. The proposed HIFU system may provide an effective method for immediate blood coagulation for arteries and veins in clinical applications.

  13. Effect of differing intensities of fatiguing dynamic contractions on contralateral homologous muscle performance.

    Science.gov (United States)

    Kawamoto, Jon-Erik; Aboodarda, Saied Jalal; Behm, David George

    2014-12-01

    The purpose of this study was to investigate different intensities of unilateral fatiguing dynamic quadriceps contractions on non-exercised, contralateral quadriceps performance. In a randomized crossover study design with 12 recreationally trained male (1.78 ± 0.05 m, 84.5 ± 7.6 kg, 30.0 ± 8.5 yrs) participants, maximal voluntary contraction (MVC) force, force developed in the first 100 ms (F100), and electromyography of the non-exercised contralateral knee extensors were measured before and after fatiguing protocols performed by ipsilateral knee extensors. Non-exercised knee extensors' endurance was also measured post-intervention. The fatigue protocols consisted of four sets of dynamic knee extensions each to task failure with 40% and 70% MVC on separate days. Both the 40% (p = 0.009, Effect Size [ES] = 0.72) and 70% (p = 0.001, ES = 2.03) conditions exhibited 23.7% and 34.6% decreases in F100 respectively with the non-exercised contralateral knee extensors. A significant time effect (p = 0.002) demonstrated that both the 40% (and 70% (conditions exhibited 4.4% (ES = 0.29) and 7.1% (ES = 0.53) force decreases from pre- to post-intervention, respectively. However, the condition * time interaction only showed a trend (p = 0.09) with moderate (40%: ES = 0.62) to large (70%: ES = 0.82) effect sizes for decreased contralateral limb force compared with control session. The 40% (p = 0.09, ES = 0.65) and 70% (p = 0.07, ES = 0.79) protocols had a tendency to induce greater contralateral force variation during sustained submaximal isometric contraction compared with control. In conclusion, this study highlighted that unilateral lower limb fatigue induced by low intensity as well as high intensity dynamic knee extensions provided some evidence of crossover fatigue with the contralateral non-exercised limb. Key PointsThere was a pattern of crossover fatigue effects with significant impairments in F100, near significant, moderate to large magnitude decrements in MVC force

  14. High performance MEAs. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-15

    The aim of the present project is through modeling, material and process development to obtain significantly better MEA performance and to attain the technology necessary to fabricate stable catalyst materials thereby providing a viable alternative to current industry standard. This project primarily focused on the development and characterization of novel catalyst materials for the use in high temperature (HT) and low temperature (LT) proton-exchange membrane fuel cells (PEMFC). New catalysts are needed in order to improve fuel cell performance and reduce the cost of fuel cell systems. Additional tasks were the development of new, durable sealing materials to be used in PEMFC as well as the computational modeling of heat and mass transfer processes, predominantly in LT PEMFC, in order to improve fundamental understanding of the multi-phase flow issues and liquid water management in fuel cells. An improved fundamental understanding of these processes will lead to improved fuel cell performance and hence will also result in a reduced catalyst loading to achieve the same performance. The consortium have obtained significant research results and progress for new catalyst materials and substrates with promising enhanced performance and fabrication of the materials using novel methods. However, the new materials and synthesis methods explored are still in the early research and development phase. The project has contributed to improved MEA performance using less precious metal and has been demonstrated for both LT-PEM, DMFC and HT-PEM applications. New novel approach and progress of the modelling activities has been extremely satisfactory with numerous conference and journal publications along with two potential inventions concerning the catalyst layer. (LN)

  15. Acute effect of resistance exercise performed at different intensities on the hemodynamics of normotensive men

    Directory of Open Access Journals (Sweden)

    Mauricio Assis Saldanha

    2016-06-01

    Full Text Available The aim of this study was to investigate the acute effect of resistance exercise performed at different intensities on the hemodynamics of normotensive men. The study included 10 normotensive and recreationally-trained men (25.40 ± 6.90 years performed the following three experimental protocols in a randomized order: a 60% of 8RM; b 80% of 8RM; c 100% of 8RM. All protocols performed six exercises (Leg Press, Vertical Bench Press, Leg Flexion, Close-Grip Seated Row, Leg Extension and Shoulder Press with three sets of eight repetitions for each exercise. Systolic blood pressure (SBP, diastolic blood pressure (DBP, heart rate (HR and double product (DP were measured at rest, at the end of exercise and during the 60-minute post-exercise. The findings showed that there was a significant reduction in the faster SBP with a longer duration (p 0.05. There were significantly higher elevations in HR and DP for 100% of 8RM at all times (p<0.0001. We conclude that high intensities (100% of 8RM promote post-exercise hypotension with faster responses and greater duration and increase HR and DP in normotensive men.

  16. Vortex dynamics and shear layer instability in high intensity cyclotrons

    CERN Document Server

    Cerfon, Antoine J

    2016-01-01

    We show that the space charge dynamics of high intensity beams in the plane perpendicular to the magnetic field in cyclotrons is described by the two-dimensional Euler equations for an incompressible fluid. This analogy with fluid dynamics gives a unified and intuitive framework to explain the beam spiraling and beam break up behavior observed in experiments and in simulations. In particular, we demonstrate that beam break up is the result of a classical instability occurring in fluids subject to a sheared flow. We give scaling laws for the instability and predict the nonlinear evolution of beams subject to it. Our work suggests that cyclotrons may be uniquely suited for the experimental study of shear layers and vortex distributions that are not achievable in Penning-Malmberg traps.

  17. Simplified shielding calculation system for high-intensity proton accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Masumura, Tomomi; Nakashima, Hiroshi; Nakane, Yoshihiro; Sasamoto, Nobuo [Center for Neutron Science, Tokai Research Establishment, Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)

    2000-06-01

    A simplified shielding calculation system is developed for applying conceptual shielding design of facilities in the joint project for high-intensity proton accelerators. The system is composed of neutron transmission calculation part for bulk shielding using simplified formulas: Moyer model and Tesch's formula, and neutron skyshine calculation part using an empirical formula: Stapleton's formula. The system is made with the Microsoft Excel software for user's convenience. This report provides a manual for the system as well as calculation conditions used in the calculation such as Moyer model's parameters. In this report preliminary results based on data at December 8, 1999, are also shown as an example. (author)

  18. Repeated high-intensity exercise in a professional rugby league.

    Science.gov (United States)

    Austin, Damien J; Gabbett, Tim J; Jenkins, David J

    2011-07-01

    The primary aim of this study was to identify and describe the frequency and duration of repeated high-intensity exercise (RHIE) bouts in Australian professional rugby league (National Rugby League) and whether these occurred at critical times during a game. Time motion analysis was used during 5 competition matches; 1 player from 3 positional groups (hit-up forward, adjustable, and outside back) was analyzed in each match. The ranges of RHIE bouts for the 3 positional groups were hit-up forwards 9-17, adjustables 2-8, and outside backs 3-7. Hit-up forwards were involved in a significantly greater number of RHIE bouts (p rugby league players are likely to encounter.

  19. Fast damping in mismatched high intensity beam transportation

    Directory of Open Access Journals (Sweden)

    V. Variale

    2001-08-01

    Full Text Available A very fast damping of beam envelope oscillation amplitudes was recently observed in simulations of high intensity beam transport, through periodic FODO cells, in mismatched conditions [V. Variale, Nuovo Cimento Soc. Ital. Fis. 112A, 1571–1582 (1999 and T. Clauser et al., in Proceedings of the Particle Accelerator Conference, New York, 1999 (IEEE, Piscataway, NJ, 1999, p. 1779]. A Landau damping mechanism was proposed at the origin of observed effect. In this paper, to further investigate the source of this fast damping, extensive simulations have been carried out. The results presented here support the interpretation of the mechanism at the origin of the fast damping as a Landau damping effect.

  20. High Performance Proactive Digital Forensics

    Science.gov (United States)

    Alharbi, Soltan; Moa, Belaid; Weber-Jahnke, Jens; Traore, Issa

    2012-10-01

    With the increase in the number of digital crimes and in their sophistication, High Performance Computing (HPC) is becoming a must in Digital Forensics (DF). According to the FBI annual report, the size of data processed during the 2010 fiscal year reached 3,086 TB (compared to 2,334 TB in 2009) and the number of agencies that requested Regional Computer Forensics Laboratory assistance increasing from 689 in 2009 to 722 in 2010. Since most investigation tools are both I/O and CPU bound, the next-generation DF tools are required to be distributed and offer HPC capabilities. The need for HPC is even more evident in investigating crimes on clouds or when proactive DF analysis and on-site investigation, requiring semi-real time processing, are performed. Although overcoming the performance challenge is a major goal in DF, as far as we know, there is almost no research on HPC-DF except for few papers. As such, in this work, we extend our work on the need of a proactive system and present a high performance automated proactive digital forensic system. The most expensive phase of the system, namely proactive analysis and detection, uses a parallel extension of the iterative z algorithm. It also implements new parallel information-based outlier detection algorithms to proactively and forensically handle suspicious activities. To analyse a large number of targets and events and continuously do so (to capture the dynamics of the system), we rely on a multi-resolution approach to explore the digital forensic space. Data set from the Honeynet Forensic Challenge in 2001 is used to evaluate the system from DF and HPC perspectives.

  1. Salutary effects of high-intensity interval training in persons with elevated cardiovascular risk.

    Science.gov (United States)

    Fleg, Jerome L

    2016-01-01

    Although moderate-intensity continuous training (MICT) has been the traditional model for aerobic exercise training for over four decades, a growing body of literature has demonstrated equal if not greater improvement in aerobic capacity and similar beneficial effects on body composition, glucose metabolism, blood pressure, and quality of life from high-intensity interval training (HIIT). An advantage of HIIT over MICT is the shorter time required to perform the same amount of energy expenditure. The current brief review summarizes the effects of HIIT on peak aerobic capacity and cardiovascular risk factors in healthy adults and those with various cardiovascular diseases, including coronary artery disease, chronic heart failure, and post heart transplantation.

  2. [Metabolic response to high intensity exercise training in sedentary hyperglycemic and hypercholesterolemic women].

    Science.gov (United States)

    Alvarez L, Cristian; Ramírez-Campillo, Rodrigo; Flores O, Marcelo; Henríquez-Olguín, Carlos; Campos J, Christian; Carrasco, Vanesa; Martínez S, Cristian; Celis-Morales, Carlos

    2013-10-01

    High intensity training could be an effective way of improving health on individuals at high metabolic risk. To investigate the effects of a high intensity training intervention on metabolic-related markers in sedentary women at high metabolic risk. Forty six sedentary women with a body mass index (BMI) over 25 kg/m² were assigned to four groups, according to their metabolic profile; hyperglycemia (H, n = 12), hyperglycemia/hypercholesterolemia (HH, n = 13), normoglycemia (N, n = 10) and normoglycemia/hypercholesterolemia (NH, n = 11). For 12 weeks and five days per week, subjects performed seven intervals of high intensity training (20 to 30 seconds) during a training session of 20 minutes. Anthropometric (body weight, body mass index (BMI), waist circumference) and metabolic variables (glucose, total cholesterol, LDL, HDL and TG) were measured at baseline, at 6 and 12 weeks of intervention. BMI and waist circumference decreased significantly after 12 weeks of intervention. Similarly, glucose decreased significantly after 12 weeks of intervention in all groups. The reduction was of higher magnitude in those groups with hyperglycemia (H = -16%, HH = -22%, N = -7,5%, NH = -9,6%). However, lipid profile (TG, total cholesterol, LDL and HDL) improved significantly only in the hypercholesterolemic groups. Physical activity programs incorporating high intensity training can improve glucose and lipid profile in women with metabolic disorders. Moreover, this benefit is greatest in those individuals with highest metabolic burden.

  3. Motor intensive anti-gravity training improves performance in dynamic balance related tasks in persons with Parkinson's disease.

    Science.gov (United States)

    Malling, Anne Sofie B; Jensen, Bente R

    2016-01-01

    Recent studies indicate that the effect of training on motor performance in persons with Parkinson's disease (PDP) is dependent on motor intensity. However, training of high motor intensity can be hard to apply in PDP due to e.g. bradykinesia, rigidity, tremor and postural instability. Therefore, the aim was to study the effect of motor intensive training performed in a safe anti-gravity environment using lower-body positive pressure (LBPP) technology on performance during dynamic balance related tasks. Thirteen male PDP went through an 8-week control period followed by 8 weeks of motor intensive antigravity training. Seventeen healthy males constituted a control group (CON). Performance during a five repetition sit-to-stand test (STS; sagittal plane) and a dynamic postural balance test (DPB; transversal plane) was evaluated. Effect measures were completion time, functional rates of force development, directional changes and force variance. STS completion time improved by 24% to the level of CON which was explained by shorter sitting-time and standing-time and larger numeric rate of force change during lowering to the chair, indicating faster vertical directional change and improved relaxation. DPB completion time tended to improve and was accompanied by improvements of functional medial and lateral rates of force development and higher vertical force variance during DPB. Our results suggest that the performance improvements may relate to improved inter-limb coordination. It is concluded that 8 weeks of motor intensive training in a safe LBPP environment improved performance during dynamic balance related tasks in PDP.

  4. Nanobiotechnology promotes noninvasive high-intensity focused ultrasound cancer surgery.

    Science.gov (United States)

    Chen, Yu; Chen, Hangrong; Shi, Jianlin

    2015-01-07

    The successful cancer eradication in a noninvasive manner is the ultimate objective in the fight against cancer. As a "bloodless scalpel," high-intensity focused ultrasound (HIFU) is regarded as one of the most promising and representative noninvasive therapeutic modalities for cancer surgery. However, large-scale clinical applications of HIFU are still in their infancy because of critical efficiency and safety issues which remain to be solved. Fortunately, recently developed nanobiotechnology provides an alternative efficient approach to improve such important issues in HIFU, especially for cancer therapy. This Research News presents the very recent exciting progresses on the elaborate design and fabrication of organic, inorganic, and organic/inorganic hybrid nanoparticles for enhancing the HIFU ablation efficiency against tumor tissues. It is highly expected that this Research News can arouse more extensive research enthusiasm on the development of functional nanomaterials for highly efficient HIFU-based synergistic therapy, which will give a promising noninvasive therapeutic modality for the successful cancer therapy with minimal damage to surrounding normal tissues, due to the noninvasive and site-specific therapeutic features of HIFU.

  5. Bunching high intensity proton beams with a CH-DTL

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, Malte; Claessens, Christine; Heilmann, Manuel; Hinrichs, Ole; Koser, Daniel; Meusel, Oliver; Noll, Daniel; Podlech, Holger; Ratzinger, Ulrich; Seibel, Anja [Institut fuer Angewandte Physik, Goethe-Universitaet Frankfurt am Main (Germany)

    2014-07-01

    The Frankfurt Neutron Source at the Stern-Gerlach-Zentrum (FRANZ) will provide ultra short neutron pulses at high intensities and repetition rates. The facility is under construction with an expected first beam by the end of 2014. A 5-Gap CH rebuncher is installed behind a coupled RFQ/IH-DTL combination at the end of the LINAC section between two magnetic quadrupole triplets. It will be used for varying the final energy between 1.8 and 2.2 MeV, as well as for focusing the proton beam bunch longitudinally, to compensate RF defocusing effects and huge space charge forces at currents up to 200 mA at the final stage of extension. Therefore high current beam dynamic simulations are in progress. They include benchmarking of different beam dynamic codes like LORASR, TraceWin and Bender (a new PIC tracking code developed at IAP), as well as validating the results by measurements. Detailed error tolerance studies, thermal simulations and examination of multipole field impact, due to the cavity geometry, are also done. Furthermore, this CH rebuncher serves as prototype for CH cavity operation at MYRRHA (Belgium), an Accelerator Driven System (ADS) for transmutation of high level nuclear waste. After copper-plating the cavity, RF conditioning will start in spring 2014.

  6. Observation of fine particle aggregating behavior induced by high intensity conditioning using high speed CCD

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The aggregating behavior between bubbles and particles induced by high intensity conditioning (HIC) was studied using high speed CCD technique. Bubble size measurement was conducted, and the attachment behavior between bubbles and particles in HIC cell and flotation cell were observed. The results show that in HIC cell, high intensity conditioning creates an advantage environment for the formation of small size bubble due to hydrodynamic cavitations, and these fine bubbles have high probability of bubble-particle collision,which will enhance fine particle flotation. The bubble-particle attachment experiments indicate that in high intensity conditioning cell, a lot of fine bubbles are produced in situ on the surface of fine particles, and most of fine particles are aggregated under the bridging action of fine bubbles. The observation of bubble-particle interaction in flotation cell illustrates that aggregates created by HIC can be loaded more easily by big air bubble in flotation cell than those created by normal conditioning.

  7. Repeated High Intensity Bouts with Long Recovery: Are Bicarbonate or Carbohydrate Supplements an Option?

    Directory of Open Access Journals (Sweden)

    Thomas Stöggl

    2014-01-01

    Full Text Available The effects of varying recovery modes and the influence of preexercise sodium bicarbonate and carbohydrate ingestion on repeated high intensity performance, acid-base response, and recovery were analyzed in 12 well-trained males. They completed three repeated high intensity running bouts to exhaustion with intervening recovery periods of 25 min under the following conditions: sodium bicarbonate, active recovery (BIC; carbohydrate ingestion, active recovery (CHO; placebo ingestion, active recovery (ACTIVE; placebo ingestion, passive recovery (PASSIVE. Blood lactate (BLa, blood gases, heart rate, and time to exhaustion were collected. The three high intensity bouts had a duration of 138±9, 124±6, and 121±6 s demonstrating a decrease from bout 1 to bout 3. Supplementation strategy had no effect on performance in the first bout, even with differences in pH and bicarbonate (HCO3-. Repeated sprint performance was not affected by supplementation strategy when compared to ACTIVE, while PASSIVE resulted in a more pronounced decrease in performance compared with all other interventions. BIC led to greater BLa, pH, and HCO3- values compared with all other interventions, while for PASSIVE the opposite was found. BLa recovery was lowest in PASSIVE; recovery in pH, and HCO3- was lower in PASSIVE and higher in BIC.

  8. Quality and performance measures of strain on intensive care capacity: a protocol for a systematic review.

    Science.gov (United States)

    Soltani, S Abolfazi; Ingolfsson, Armann; Zygun, David A; Stelfox, Henry T; Hartling, Lisa; Featherstone, Robin; Opgenorth, Dawn; Bagshaw, Sean M

    2015-11-12

    The matching of critical care service supply with demand is fundamental for the efficient delivery of advanced life support to patients in urgent need. Mismatch in this supply/demand relationship contributes to "intensive care unit (ICU) capacity strain," defined as a time-varying disruption in the ability of an ICU to provide well-timed and high-quality intensive care support to any and all patients who are or may become critically ill. ICU capacity strain leads to suboptimal quality of care and may directly contribute to heightened risk of adverse events, premature discharges, unplanned readmissions, and avoidable death. Unrelenting strain on ICU capacity contributes to inefficient health resource utilization and may negatively impact the satisfaction of patients, their families, and frontline providers. It is unknown how to optimally quantify the instantaneous and temporal "stress" an ICU experiences due to capacity strain. We will perform a systematic review to identify, appraise, and evaluate quality and performance measures of strain on ICU capacity and their association with relevant patient-centered, ICU-level, and health system-level outcomes. Electronic databases (i.e., MEDLINE, EMBASE, CINAHL, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, Web of Science, and the Agency of Healthcare Research and Quality (AHRQ) - National Quality Measures Clearinghouse (NQMC)) will be searched for original studies of measures of ICU capacity strain. Selected gray literature sources will be searched. Search themes will focus on intensive care, quality, operations management, and capacity. Analysis will be primarily narrative. Each identified measure will be defined, characterized, and evaluated using the criteria proposed by the US Strategic Framework Board for a National Quality Measurement and Reporting System (i.e., importance, scientific acceptability, usability, feasibility). Our systematic review will comprehensively

  9. High-order harmonic generation at high laser intensities beyond the tunnel regime

    CERN Document Server

    Pérez-Hernández, J A; Lewenstein, M; Zaïr, A; Roso, L

    2014-01-01

    We present studies of high-order harmonic generation (HHG) at laser intensities well above saturation. We use driving laser pulses which present a particular electron dynamics in the turn-on stage. Our results predict an increasing on the harmonic yield, after an initial dropping, when the laser intensity is increased. This fact contradicts the general belief of a progressive degradation of the harmonic emission at ultrahigh intensities. We have identified a particular set of trajectories which emerges in the turn-on stage of these singular laser pulses, responsible of the unexpected growth on the harmonic efficiency at this high intensity regime. Our study combines two complementary approaches: classical analysis and full quantum mechanical calculations resulting from the numerical integration of the 3-dimensional time-dependent Schr\\"odinger equation complemented with the time-frequency analysis.

  10. The effects of light emitting diode therapy following high intensity exercise.

    Science.gov (United States)

    Denis, Romain; O'Brien, Christopher; Delahunt, Eamonn

    2013-05-01

    To determine the effects of light emitting diode therapy (LEDT) irradiation on blood lactate concentration ([La]) clearance, peak power output and fatigue index (FI) following high intensity fatiguing exercise. Single-blinded randomised cross-over placebo controlled trial. University College Dublin, Institute for Sport and Health, Human performance laboratory. Eighteen healthy male athletes were recruited from field-based sports (including soccer, hockey and rugby union) and participated in the present study. Dependent variables were the peak power output elicited during the Wingate Anaerobic Test (WAnT), FI and [La] before and after each exercise. WAnT performance was measured prior to high intensity fatiguing exercise (Yo-Yo IR2), prior to LEDT or placebo, and following LEDT or placebo. [La] was measured at baseline, immediately after the Yo-Yo IR2, and in the 3rd, 9th, and 15th min following LEDT or placebo condition. No significant group by treatment interactions were observed for any outcome measures (P > 0.05). We conclude that LEDT irradiation applied following high intensity exercise was not effective and has no immediate effect on [La] clearance, peak power and FI, and thus has no significant effect on muscle recovery in athletes at the intensity and irradiation parameters used in the present study. Further research using different parameters is required to determine how LEDT may contribute to post-exercise recovery. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Echinococcus granulosus: protoscolicidal effect of high intensity focused ultrasound.

    Science.gov (United States)

    Zou, Xiaoyi; Wang, Junan; Zhao, Hailong; Zhang, Jing; Wu, Weihua; Ye, Bin

    2009-04-01

    High intensity focused ultrasound (HIFU) is a new non-invasive technique which can cause cell death and tissue necrosis by focusing high-energy ultrasonic waves on a single location. The aim of our work is to investigate the damaging effect of HIFU on Echinococcus granulosus protoscolices, as well as its inhibitory effect on growth of hydatid cysts derived from protoscolices. The damaging effect of HIFU on protoscolices was investigated by following parasite mortality after irradiation, while the inhibitory effect was investigated by infection experiments in vivo. The results demonstrated that HIFU was able to damage protoscolices and the protoscolicidal effect was dose-dependent and showed late-onset. The growth of protoscolices that survived the exposure to HIFU was obviously suppressed in vitro, and the mean weight of hydatid cysts resulting from such protoscolices in the experimental group was less than that in controls. Evidences including the protoscolicidal effect, fragmentized protoscolices and low post exposure temperatures, suggest that cavitation may contribute to the protoscolicidal effect of HIFU. In addition, the structure of the germinal membrane in cysts developing from the irradiated protoscolices was not as normal or intact as that from non-irradiated ones, and morphological changes related to degeneration were observed, suggesting that HIFU could prevent protoscolices from developing normal germinal membrane and consequently stop the proliferation of secondary hydatid cysts. HIFU demonstrated damaging effect on protoscolices, inhibited the growth of protoscolices in vitro and in vivo, and could be a possible therapeutic option for cystic echinococcosis.

  12. Interaction of High Intensity Electromagnetic Waves with Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    G. Shvets

    2008-10-03

    The focus of our work during the duration of this grant was on the following areas: (a) the fundamental plasma physics of intense laser-plasma interactions, including the nonlinear excitation of plasma waves for accelerator applications, as well as the recently discovered by us phenomenon of the relativistic bi-stability of relativistic plasma waves driven by a laser beatwave; (b) interaction of high power microwave beams with magnetized plasma, including some of the recently discovered by us phenomena such as the Undulator Induced Transparency (UIT) as well as the new approaches to dynamic manipulation of microwave pulses; (c) investigations of the multi-color laser pulse interactions in the plasma, including the recently discovered by us phenomenon of Electromagnetic Cascading (EC) and the effect of the EC of three-dimensional dynamics of laser pulses (enhanced/suppressed selffocusing etc.); (d) interaction of high-current electron beams with the ambient plasma in the context of Fast Ignitor (FI) physics, with the emphasis on the nonlinear dynamics of the Weibel instability and beam filamentation.

  13. High performance solar Stirling system

    Science.gov (United States)

    Stearns, J. W.; Haglund, R.

    1981-01-01

    A full-scale Dish-Stirling system experiment, at a power level of 25 kWe, has been tested during 1981 on the Test Bed Concentrator No. 2 at the Parabolic Dish Test Site, Edwards, CA. Test components, designed and developed primarily by industrial contractors for the Department of Energy, include an advanced Stirling engine driving an induction alternator, a directly-coupled solar receiver with a natural gas combustor for hybrid operation and a breadboard control system based on a programmable controller and standard utility substation components. The experiment demonstrated practicality of the solar Stirling application and high system performance into a utility grid. This paper describes the design and its functions, and the test results obtained.

  14. High Performance Perovskite Solar Cells.

    Science.gov (United States)

    Tong, Xin; Lin, Feng; Wu, Jiang; Wang, Zhiming M

    2016-05-01

    Perovskite solar cells fabricated from organometal halide light harvesters have captured significant attention due to their tremendously low device costs as well as unprecedented rapid progress on power conversion efficiency (PCE). A certified PCE of 20.1% was achieved in late 2014 following the first study of long-term stable all-solid-state perovskite solar cell with a PCE of 9.7% in 2012, showing their promising potential towards future cost-effective and high performance solar cells. Here, notable achievements of primary device configuration involving perovskite layer, hole-transporting materials (HTMs) and electron-transporting materials (ETMs) are reviewed. Numerous strategies for enhancing photovoltaic parameters of perovskite solar cells, including morphology and crystallization control of perovskite layer, HTMs design and ETMs modifications are discussed in detail. In addition, perovskite solar cells outside of HTMs and ETMs are mentioned as well, providing guidelines for further simplification of device processing and hence cost reduction.

  15. High performance solar Stirling system

    Science.gov (United States)

    Stearns, J. W.; Haglund, R.

    1981-12-01

    A full-scale Dish-Stirling system experiment, at a power level of 25 kWe, has been tested during 1981 on the Test Bed Concentrator No. 2 at the Parabolic Dish Test Site, Edwards, CA. Test components, designed and developed primarily by industrial contractors for the Department of Energy, include an advanced Stirling engine driving an induction alternator, a directly-coupled solar receiver with a natural gas combustor for hybrid operation and a breadboard control system based on a programmable controller and standard utility substation components. The experiment demonstrated practicality of the solar Stirling application and high system performance into a utility grid. This paper describes the design and its functions, and the test results obtained.

  16. Caffeine intake improves intense intermittent exercise performance and reduces muscle interstitial potassium accumulation

    DEFF Research Database (Denmark)

    Mohr, Magni; Nielsen, Jens Jung; Bangsbo, Jens

    2011-01-01

    The effect of oral caffeine ingestion on intense intermittent exercise performance and muscle interstitial ion concentrations was examined. The study consists of two studies (S1 and S2). In S1 twelve subjects completed the Yo-Yo intermittent recovery level 2 (Yo-Yo IR2) test with prior caffeine (6...... mg/kg b.w.; CAF) or placebo (PLA) intake. In S2 six subjects performed one low intense (20 W) and three intense (50 W) 3-min (separated by 5 min) one-legged knee-extension exercise bouts with (CAF) and without (CON) prior caffeine supplementation for determination of muscle interstitial K(+) and Na...

  17. Creatine kinase response to high-intensity aerobic exercise in adult-onset muscular dystrophy

    DEFF Research Database (Denmark)

    Andersen, Søren P; Sveen, Marie-Louise; Hansen, Regitze S

    2013-01-01

    We investigated the effect of high-intensity exercise on plasma creatine kinase (CK) in patients with muscular dystrophies.......We investigated the effect of high-intensity exercise on plasma creatine kinase (CK) in patients with muscular dystrophies....

  18. Hybrid ventilation systems and high performance buildings

    Energy Technology Data Exchange (ETDEWEB)

    Utzinger, D.M. [Wisconsin Univ., Milwaukee, WI (United States). School of Architecture and Urban Planning

    2009-07-01

    This paper described hybrid ventilation design strategies and their impact on 3 high performance buildings located in southern Wisconsin. The Hybrid ventilation systems combined occupant controlled natural ventilation with mechanical ventilation systems. Natural ventilation was shown to provide adequate ventilation when appropriately designed. Proper control integration of natural ventilation into hybrid systems was shown to reduce energy consumption in high performance buildings. This paper also described the lessons learned from the 3 buildings. The author served as energy consultant on all three projects and had the responsibility of designing and integrating the natural ventilation systems into the HVAC control strategy. A post occupancy evaluation of building energy performance has provided learning material for architecture students. The 3 buildings included the Schlitz Audubon Nature Center completed in 2003; the Urban Ecology Center completed in 2004; and the Aldo Leopold Legacy Center completed in 2007. This paper included the size, measured energy utilization intensity and percentage of energy supplied by renewable solar power and bio-fuels on site for each building. 6 refs., 2 tabs., 6 figs.

  19. Compliance with High-Intensity Radiated Fields Regulations - Emitter's Perspective

    Science.gov (United States)

    Statman, Joseph; Jamnejad, Vahraz; Nguyen, Lee

    2012-01-01

    NASA's Deep Space Network (DSN) uses high-power transmitters on its large antennas to communicate with spacecraft of NASA and its partner agencies. The prime reflectors of the DSN antennas are parabolic, at 34m and 70m in diameter. The DSN transmitters radiate Continuous Wave (CW) signals at 20 kW - 500 kW at X-band and S-band frequencies. The combination of antenna reflector size and high frequency results in a very narrow beam with extensive oscillating near-field pattern. Another unique feature of the DSN antennas is that they (and the radiated beam) move mostly at very slow sidereal rate, essentially identical in magnitude and at the opposite direction of Earth rotation.The DSN is in the process of revamping its documentation to provide analysis of the High Intensity Radiation Fields (HIRF) environment resulting from radio frequency radiation from DSN antennas for comparison to FAA regulations regarding certification of HIRF protection as outlined in the FAA regulations on HIRF protection for aircraft electrical and electronic systems (Title 14, Code of Federal Regulations (14 CFR) [section sign][section sign] 23.1308, 25.1317, 27.1317, and 29.1317).This paper presents work done at JPL, in consultation with the FAA. The work includes analysis of the radiated field structure created by the unique DSN emitters (combination of transmitters and antennas) and comparing it to the fields defined in the environments in the FAA regulations. The paper identifies areas that required special attention, including the implications of the very narrow beam of the DSN emitters and the sidereal rate motion. The paper derives the maximum emitter power allowed without mitigation and the mitigation zones, where required.Finally, the paper presents summary of the results of the analyses of the DSN emitters and the resulting DSN process documentation.

  20. New technologies in lighting systems for high-speed film and photography regarding high-intensity and heat problems

    Science.gov (United States)

    Severon, Burkhard

    1991-04-01

    Increasing frame rates and the heat sensibility of test objects forced the development of new lighting systems. For example at the automotive industry, where continuous light sources are indispensable for the high speed photography of car crash tests and automobile components tests, the further development of high efficient safety systems, so as Air-Bag systems, needs very datailed analysis of the accelerated motions. Frame rates from 2.000 up to 10.000 frames per second are requested and beside adequate camera systems and film material, this also means high intensive lighting systems. The need for high intensity could be easy achieved by the use of additional light fixtures but the request for more intensity comes along with the problem of heat. The test objects and the auxiliary materials become more and more temperature- sensitive. Very offen they have to be used under strict climate conditions. Mainly there where the test objects are already placed inside the illuminated area, the heat radiation of the light sources to the test objects have to be reduced. So high intensive, flicker free and less heat are today's requirements of light performance. This paper will present solutions to meet those demands.

  1. Effect of high-intensity training on endothelial function in patients with cardiovascular and cerebrovascular disease: A systematic review

    Directory of Open Access Journals (Sweden)

    Mia Kolmos

    2016-12-01

    Full Text Available Objectives: Exercise improves endothelial dysfunction, the key manifestation of cardiovascular and cerebrovascular disease, and is recommended in both cardiovascular and cerebrovascular rehabilitation. Disagreement remains, however, on the role of intensity of exercise. The purpose of this review was to gather current knowledge on the effects of high-intensity training versus moderate-intensity continuous exercise on endothelial function in cardiovascular and cerebrovascular patients. Methods: A systematic review was performed in PubMed database, Embase and Cochrane libraries and on PEDro using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Studies were restricted to cardiovascular and cerebrovascular patients, and healthy subjects as general reference. Interventions comprised of high-intensity training alone, high-intensity training compared to moderate-intensity continuous exercise, or no training, with endothelial function as outcome measure. Endothelial function was measured either physiologically by flow-mediated dilatation and/or by systemic biomarkers. Data were analyzed descriptively due to non-comparability for a meta-analysis to be performed. Results: A total of 20 studies were included in the review. Although there was great heterogenecity in design, population and exercise protocols, all studies found high-intensity training to be safe. High-intensity training was equal to moderate-intensity continuous exercise through improvement in endothelial function in 15 of the 20 selected studies, as measured by flow-mediated dilatation, nitric oxide bioavailability and circulating biomarkers. Only a few studies examined high-intensity training in cerebrovascular patients, none with endothelial function as outcome. Conclusion: High-intensity training is promising as a time-efficient exercise strategy in cardiovascular rehabilitation, but data on endothelial effects in cerebrovascular rehabilitation are

  2. Intense highly charged ion beam production and operation with a superconducting electron cyclotron resonance ion source

    Science.gov (United States)

    Zhao, H. W.; Sun, L. T.; Guo, J. W.; Lu, W.; Xie, D. Z.; Hitz, D.; Zhang, X. Z.; Yang, Y.

    2017-09-01

    The superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL) is a superconducting-magnet-based electron cyclotron resonance ion source (ECRIS) for the production of intense highly charged heavy ion beams. It is one of the best performing ECRISs worldwide and the first superconducting ECRIS built with an innovative magnet to generate a high strength minimum-B field for operation with heating microwaves up to 24-28 GHz. Since its commissioning in 2005, SECRAL has so far produced a good number of continuous wave intensity records of highly charged ion beams, in which recently the beam intensities of 40Ar+ and 129Xe26+ have, for the first time, exceeded 1 emA produced by an ion source. Routine operations commenced in 2007 with the Heavy Ion accelerator Research Facility in Lanzhou (HIRFL), China. Up to June 2017, SECRAL has been providing more than 28,000 hours of highly charged heavy ion beams to the accelerator demonstrating its great capability and reliability. The great achievement of SECRAL is accumulation of numerous technical advancements, such as an innovative magnetic system and an efficient double-frequency (24 +18 GHz ) heating with improved plasma stability. This article reviews the development of SECRAL and production of intense highly charged ion beams by SECRAL focusing on its unique magnet design, source commissioning, performance studies and enhancements, beam quality and long-term operation. SECRAL development and its performance studies representatively reflect the achievements and status of the present ECR ion source, as well as the ECRIS impacts on HIRFL.

  3. High-intensity interval training vs. moderate-intensity continuous training in the prevention/management of cardiovascular disease

    OpenAIRE

    S Hussain; Macaluso, A; Pearson, S.

    2016-01-01

    Moderate-intensity continuous training (MICT) has long been considered the most effective exercise treatment modality for the prevention and management of cardiovascular disease, but more recently high-intensity interval training (HIIT) has emerged into the clinical environment has been viewed as a potential alternative to MICT in accruing such benefits. HIIT was initially found to induce significant improvements in numerous physiological and health-related indices, to a similar if not superi...

  4. COLLIMATORS AND MATERIALS FOR HIGH INTENSITY HEAVY ION SYNCHROTRONS

    CERN Document Server

    Stadlmann, J; Kollmus, H; Spiller, P; Strasik, I; Tahir, N A; Tomut, M; Trautmann, C

    2012-01-01

    The operation of high power high brightness accelerators requires huge efforts for beam cleaning and machine protection. Within the WP 8 (ColMat) of the EU research framework EuCARD[1] we investigate new materials and methods for beam collimation and machine protection. We present an overview of these activities at the GSI Helmholtzzentrum f¨ur Schwerionenforschung, Darmstadt. Simulations of accidental beam losses in LHC and SIS100 have been performed. Scenarios for halo collimation of heavy ions and protons in SIS100 routine operation have been investigated. A prototype of a cryogenic collimator for charge exchange losses during intermediate charge state heavy ion operation in SIS100 has been build and tested with beam. Several candidates of advanced composite materials for collimation system upgrades of present and future high power accelerators have been irradiated and their properties are being characterized. Most deliverables and milestones of the R&D programme were already reached before the end of...

  5. A review of adolescent high-intensity interval training.

    Science.gov (United States)

    Logan, Greig R M; Harris, Nigel; Duncan, Scott; Schofield, Grant

    2014-08-01

    Despite the promising evidence supporting positive effects of high-intensity interval training (HIIT) on the metabolic profile in adults, there is limited research targeting adolescents. Given the rising burden of chronic disease, it is essential to implement strategies to improve the cardiometabolic health in adolescence, as this is a key stage in the development of healthy lifestyle behaviours. This narrative review summarises evidence of the relative efficacy of HIIT regarding the metabolic health of adolescents. Methodological inconsistencies confound our ability to draw conclusions; however, there is meaningful evidence supporting HIIT as a potentially efficacious exercise modality for use in the adolescent cohort. Future research must examine the effects of various HIIT protocols to determine the optimum strategy to deliver cardiometabolic health benefits. Researchers should explicitly show between-group differences for HIIT intervention and steady-state exercise or control groups, as the magnitude of difference between HIIT and other exercise modalities is of key interest to public health. There is scope for research to examine the palatability of HIIT as an exercise modality for adolescents through investigating perceived enjoyment during and after HIIT, and consequent long-term exercise adherence.

  6. High intensity ultrasound modified ovalbumin: Structure, interface and gelation properties.

    Science.gov (United States)

    Xiong, Wenfei; Wang, Yuntao; Zhang, Chunlan; Wan, Jiawei; Shah, Bakht Ramin; Pei, Yaqiong; Zhou, Bin; Li, Jin; Li, Bin

    2016-07-01

    Influence of high intensity ultrasound (HIUS) on the structure and properties of ovalbumin (OVA) were investigated. It was found that the subunits and secondary structure of OVA did not change significantly with HIUS treatment from the electrophoretic patterns and circular dichroism (CD) spectrum. The amount of free sulfhydryl groups increased and intrinsic fluorescence spectra analysis indicated changes in the tertiary structure and partial unfold of OVA after sonication increased. Compared with the untreated OVA, HIUS treatment increased the emulsifying activity and foaming ability, and decreased interface tension (oil-water and air-water interface), which due to the increased surface hydrophobicity and decreased the surface net charge in OVA, while the emulsifying and foaming stability had no remarkable differences. The increased particle size may be attributed to formation of protein aggregates. Moreover, the gelation temperatures of HIUS-treated samples were higher than the untreated OVA according to the temperature sweep model rheology, and this effect was consistent with the increased in surface hydrophobicity for ultrasound treated OVA. These changes in functional properties of OVA would promote its application in food industry. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Treatment of glaucoma with high intensity focused ultrasound.

    Science.gov (United States)

    Aptel, Florent; Lafon, Cyril

    2015-05-01

    Glaucoma is a common disease mainly due to an increase in pressure inside the eye, leading to a progressive destruction of the optic nerve, potentially to blindness. Intraocular pressure (IOP) is the result of a balance between production of liquid that fills the eye--aqueous humour--and its resorption. All treatments for glaucoma aim to reduce IOP and can therefore have two mechanisms of action: reducing aqueous humour production by the partial destruction or medical inhibition of the ciliary body--the anatomical structure responsible for production of aqueous humour--or facilitating the evacuation of aqueous humour from the eye. Several physical methods can be used to destroy the ciliary body, e.g. laser, cryotherapy, microwave. All these methods have two major drawbacks: they are non-selective for the organ to be treated and they have an unpredictable dose–effect relationship. High intensity focused ultrasound (HIFU) can be used to coagulate the ciliary body and avoid these drawbacks. A commercially available device was marketed in the 1980s, but later abandoned, essentially for technical reasons. A smaller circular device using miniaturised transducers was recently developed and proposed for clinical practice. Experimental studies have shown selective coagulation necrosis of the treated ciliary body. The first three clinical trials in humans have shown that this device was well tolerated and allowed a significant, predictable and sustained reduction of IOP. The aim of this contribution is to present a summary of the work concerning the use of HIFU to treat glaucoma.

  8. Robotic Assisted Laparoscopic Prostatectomy after High Intensity Focused Ultrasound Failure

    Directory of Open Access Journals (Sweden)

    Leon Telis

    2017-01-01

    Full Text Available Background. Prostate cancer is the most common cancer diagnosed in men. As new focal therapies become more popular in treatment of prostate cancer, failure cases requiring salvage therapy with either surgical or other techniques are being reported. Objective. To report the options in treatment of prostate cancer after recurrence or failure of the primary treatment modality. Methods. We report a salvage robotic assisted laparoscopic radical prostatectomy (RALP for prostate cancer recurrence following high intensity focused ultrasound treatment (HIFU in the United States. Results. A 67-year-old man who underwent HIFU treatment for prostate adenocarcinoma 2 years prior was presented with a rising prostate specific antigen of 6.1 ng/mL to our clinic. A biopsy proven recurrent disease in the area of previous treatment documented the failure of treatment. The patient elected to undergo a salvage RALP. The operation time was 159 minutes. The patient was discharged from the hospital on postoperative day 1 with no complications. The catheter was removed on post-op day 10. The patient reserved sexual function and urinary continence. The PSA levels on 6 months’ follow-up are undetectable. Conclusions. Salvage RALP is an effective and safe treatment choice for recurrent prostate adenocarcinoma following failed HIFU treatment if operated by an experienced surgeon.

  9. Limitations in intense exercise performance of athletes - effect of speed endurance training on ion handling and fatigue development

    DEFF Research Database (Denmark)

    Hostrup, Morten; Bangsbo, Jens

    2016-01-01

    Mechanisms underlying fatigue development and limitations for performance during intense exercise have been intensively studied during the past couple of decades. Fatigue development may involve several interacting factors and depends on type of exercise undertaken and training level...... and power output during intense exercise. Regular speed endurance training (SET), i.e. exercise performed at intensities above that corresponding to maximum oxygen consumption (VO2max ), enhances intense exercise performance. However, most of the studies that have provided mechanistic insight...

  10. Differences in acoustic and perceptual parameters of the voice between elderly and young women at habitual and high intensity.

    Science.gov (United States)

    Mazzetto de Menezes, Keyla S; Master, Suely; Guzman, Marco; Bortnem, Cori; Ramos, Luiz Roberto

    2014-01-01

    The present study aimed to compare elderly and young female voices in habitual and high intensity. The effect of increased intensity on the acoustic and perceptual parameters was assessed. Sound pressure level, fundamental frequency, jitter, shimmer, and harmonic to noise ratio were obtained at habitual and high intensity voice in a group of 30 elderly women and 30 young women. Perceptual assessment was also performed. Both groups demonstrated an increase in sound pressure level and fundamental frequency from habitual voice to high intensity voice. No differences were found between groups in any acoustic variables on samples recorded with habitual intensity level. No significant differences between groups were found in habitual intensity level for pitch, hoarseness, roughness, and breathiness. Asthenia and instability obtained significant higher values in elderly than young participants, whereas, the elderly demonstrated lower values for perceived tension and loudness than young subjects. Acoustic and perceptual measures do not demonstrate evident differences between elderly and young speakers in habitual intensity level. The parameters analyzed may lack the sensitivity necessary to detect differences in subjects with normal voices. Phonation with high intensity highlights differences between groups, especially in perceptual parameters. Therefore, high intensity should be included to compare elderly and young voice. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  11. Low-volume high-intensity swim training is superior to high-volume low-intensity training in relation to insulin sensitivity and glucose control in inactive middle-aged women

    DEFF Research Database (Denmark)

    Connolly, Luke J; Nordsborg, Nikolai Baastrup; Nyberg, Michael Permin

    2016-01-01

    to an inactive control (n = 20; CON), a high-intensity low-volume (n = 21; HIT) or a low-intensity high-volume (n = 21; LIT) training group. During the 15-week intervention period, HIT performed 3 weekly 6-10 × 30-s all-out swimming intervals (average heart rate (HR) = 86 ± 3 % HRmax) interspersed by 2-min...... adhesion molecule 1 had decreased (P training strategy for improving insulin sensitivity, glucose control and biomarkers of vascular function...

  12. Design and construction of a reverberation chamber for high-intensity acoustic testing.

    Science.gov (United States)

    Slusser, R. A.

    1973-01-01

    A high-intensity acoustic test facility was constructed at the Jet Propulsion Laboratory (JPL) to support the Mariner Mars 1971 project. For ease of construction, the reverberation chamber itself is rectangular, which resulted in very little sacrifice in acoustic performance. Levels as high as 156 dB can be achieved with the chamber empty and test levels of 150 dB have been used with a Mariner Mars spacecraft model (full size) in the chamber. Levels as high as this must be generated using electropneumatic transducers, which modulate gaseous nitrogen to this facility.

  13. Inelastic scattering in condensed matter with high intensity Moessbauer radiation

    Energy Technology Data Exchange (ETDEWEB)

    Yelon, W.B.; Schupp, G.

    1990-10-01

    We give a progress report for the work which has been carried out in the last three years with DOE support. A facility for high-intensity Moessbauer scattering is now fully operational at the University of Missouri Research Reactor (MURR) as well as facility at Purdue, using special isotopes produced at MURR. High precision, fundamental Moessbauer effect studies have been carried out using scattering to filter the unwanted radiation. These have led to a new Fourier transform method for describing Moessbauer effect (ME) lineshape and a direct method of fitting ME data to the convolution integral. These methods allow complete correction for source resonance self absorption (SRSA) and the accurate representation of interference effects that add an asymmetric component to the ME lines. We have begun applying these techniques to attenuated ME sources whose central peak has been attenuated by stationary resonant absorbers, to more precisely determine interference parameters and line-shape behavior in the resonance asymptotic region. This analysis is important to both the fundamental ME studies and to scattering studies for which a deconvolution is essential for extracting the correct recoilless fractions and interference parameters. A number of scattering studies have been successfully carried out including a study of the thermal diffuse scattering in Si, which led to an analysis of the resolution function for gamma-ray scattering. Also studied was the anharmonic motion in Na and the satellite reflection Debye-Waller factor in TaS{sub 2}, which indicate phason rather than phonon behavior. We have begun quasielastic diffusion studies in viscous liquids and current results are summarized. These advances, coupled to our improvements in MIcrofoil Conversion Electron spectroscopy lay the foundation for the proposed research outlined in this request for a three-year renewal of DOE support.

  14. Gamma scattering in condensed matter with high intensity Moessbauer radiation

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    We give a progress report for the work which has been carried out in the last three years with DOE support. A facility for high-intensity Moessbauer scattering is now fully operational at the University of Missouri Research Reactor (MURR) as well as a facility at Purdue, using special isotopes produced at MURR. High precision, fundamental Moessbauer effect studies have been carried out using scattering to filter the unwanted radiation. These have led to a new Fourier transform method for describing Moessbauer effect (ME) lineshape and a direct method of fitting ME data to the convolution integral. These methods allow complete correction for source resonance self absorption (SRSA) and the accurate representation of interference effects that add an asymmetric component to the ME lines. We have begun applying these techniques to attenuated ME sources whose central peak has been attenuated by stationary resonant absorbers, to more precisely determine interference parameters and line-shape behavior in the resonance asymptotic region. This analysis is important to both the fundamental ME studies and to scattering studies for which a deconvolution is essential for extracting the correct recoilless fractions and interference parameters. A number of scattering studies have been successfully carried out including a study of the thermal diffuse scattering in Si, which led to an analysis of the resolution function for gamma-ray scattering. Also studied was the anharmonic motion in Na and the satellite reflection Debye-Waller factor in TaS{sub 2}, which indicate phason rather than phonon behavior. We have begun quasielastic diffusion studies in viscous liquids and current results are summarized. These advances, coupled to our improvements in MIcrofoil Conversion Electron spectroscopy lay the foundation for the proposed research outlined in this request for a three-year renewal of DOE support.

  15. HIGH-INTENSITY FOCUSED ULTRASOUND CASTRATION FOR BREAST CANCER PATIENTS

    Institute of Scientific and Technical Information of China (English)

    王书文; 和新盈; 石景森; 赵东利; 李明众; 王诚; 薛文华

    2003-01-01

    Objective: To evaluate the safety and efficacy of external high-intensity focused ultrasound(HIFU) castration for breast cancerous patients after mastectomy if they are at a high risk of recurrence. Methods: We recruited 52 consecutive patients with primary operable breast cancer who were treated with mastectomy with excision of regional lymph nodes. Patients were positive for ER and PR immuno- cytochemical staining, node-positive, un-menopause, over 40 years old and were divided into two groups randomly. For castration, 26 patients received one or two times of HIFU treatment within five days, and the other patients received radiotherapy with DT 18Gy/9 f/11days. During and after the treatment, local changes and systemic response of the patients were observed. Results: After 1 month treatment, levels of serum E1 and E2 were significantly decreased compared to before treatment in HIFU groups (P<0.01 and P<0.001). The same changes were occurred in radiotherapy(RT) groups (P<0.05 and P<0.01). The levels of serum E1 or E2 in RT groups were higher than in HIFU groups (P<0.05). The symptom distribution of 'climacteric syndrome' of HIFU groups were significantly different from RT groups (P<0.01). The follow-up time was 4 months. The incidence of amenorrhea was 100% in all patients. No serious complications were seen. The temperature, pulse, blood pressure, and respiratory rate of the patients were almost normal. Conclusion: We have shown that the use of HIFU in the castrating of patients with breast cancer is feasible, safe and effective. This technology may provide a rapid noninvasive alterative to conventional bilateral oophorectomy or RT castration.

  16. Optimisation extraction of chondroitin sulfate from fish bone by high intensity pulsed electric fields.

    Science.gov (United States)

    He, Guidan; Yin, Yongguang; Yan, Xiaoxia; Yu, Qingyu

    2014-12-01

    High intensity pulsed electric fields (PEF) was used to extract chondroitin sulphate (CS) from fish bone. Results show that PEF extraction speed is much faster, and the content of CS is much higher compared with traditional methods. Variation of PEF parameters and the content of CS were determined by single factor experiments. The processing conditions were optimised by quadratic general rotary unitised design experiments. The maximum yield of 6.92 g/L was achieved under the following conditions: material-liquid ratio of 1:15 g/mL, electric field intensity of 16.88 kV/cm, pulse number of 9, and NaOH concentration of 3.24%. The purity of CS was analysed by agarose gel electrophoresis. CS purity was high, and the extract did not contain any other glycosaminoglycans. PEF can be widely used to extract CS with non-thermal performance, high speed, and low pollution.

  17. REPORT OF THE SNOWMASS M6 WORKING GROUP ON HIGH INTENSITY PROTON SOURCES.

    Energy Technology Data Exchange (ETDEWEB)

    CHOU,W.; WEI,J.

    2001-08-14

    The M6 working group had more than 40 active participants (listed in Section 4). During the three weeks at Snowmass, there were about 50 presentations, covering a wide range of topics associated with high intensity proton sources. The talks are listed in Section 5. This group also had joint sessions with a number of other working groups, including E1 (Neutrino Factories and Muon Colliders), E5 (Fixed-Target Experiments), M1 (Muon Based Systems), T4 (Particle Sources), T5 (Beam dynamics), T7 (High Performance Computing) and T9 (Diagnostics). The M6 group performed a survey of the beam parameters of existing and proposed high intensity proton sources, in particular, of the proton drivers. The results are listed in Table 1. These parameters are compared with the requirements of high-energy physics users of secondary beams in Working Groups E1 and E5. According to the consensus reached in the E1 and E5 groups, the U.S. HEP program requires an intense proton source, a 1-4 MW Proton Driver, by the end of this decade.

  18. Tune measurements with high intensity ion beams at GSI SIS-18

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Rahul [GSI, Darmstadt (Germany); TEMF, TU Darmstadt (Germany); Forck, Peter; Kowina, Piotr; Kaufmann, Wolfgang [GSI, Darmstadt (Germany); Weiland, Thomas [TEMF, TU Darmstadt (Germany)

    2012-07-01

    A precise tune measurement during a full accelerating cycle is required to achieve stable high current operation. A new system has been commissioned at GSI for position, orbit and tune measurements. It consists of three distinct parts; an exciter which provides power to excite coherent betatron oscillations in the bunched beam; Fast ADCs to digitize the BPM signals at 125 MSa/s; the post processing electronics uses digitized BPM signals to acquire one position value per bunch. Subsequently the baseband tune is determined by Fourier transformation of the position data. Experiments were conducted to understand the effects of high beam intensity on tune at injection plateau (11.4 MeV/u) and during acceleration ramp (11.4-600 MeV/u). These experiments were performed with U{sup 73+} and Ar{sup 18+} ion beam at highest achievable intensities of 2.10{sup 9} and 2.5.10{sup 10} respectively. Tune shift with increased intensity was observed. The working principle of the tune measurement system and observed high intensity effects on tune will be reported in this contribution.

  19. Acute Effect of High-Intensity Eccentric Exercise on Vascular Endothelial Function in Young Men.

    Science.gov (United States)

    Choi, Youngju; Akazawa, Nobuhiko; Zempo-Miyaki, Asako; Ra, Song-Gyu; Shiraki, Hitoshi; Ajisaka, Ryuichi; Maeda, Seiji

    2016-08-01

    Choi, Y, Akazawa, N, Zempo-Miyaki, A, Ra, S-G, Shiraki, H, Ajisaka, R, and Maeda, S. Acute effect of high-intensity eccentric exercise on vascular endothelial function in young men. J Strength Cond Res 30(8): 2279-2285, 2016-Increased central arterial stiffness is as an independent risk factor for cardiovascular disease. Evidence regarding the effects of high-intensity resistance exercise on vascular endothelial function and central arterial stiffness is conflicting. The purpose of this study was to examine the effects of acute high-intensity eccentric exercise on vascular endothelial function and central arterial stiffness. We evaluated the acute changes in endothelium-dependent flow-mediated dilation (FMD), low-flow-mediated constriction (L-FMC), and arterial stiffness after high-intensity eccentric exercise. Seven healthy, sedentary men (age, 24 ± 1 year) performed maximal eccentric elbow flexor exercise using their nondominant arm. Before and 45 minutes after eccentric exercise, carotid arterial compliance and brachial artery FMD and L-FMC in the nonexercised arm were measured. Carotid arterial compliance was significantly decreased, and β-stiffness index significantly increased after eccentric exercise. Brachial FMD was significantly reduced after eccentric exercise, whereas there was no significant difference in brachial L-FMC before and after eccentric exercise. A positive correlation was detected between change in arterial compliance and change in FMD (r = 0.779; p ≤ 0.05), and a negative correlation was detected between change in β-stiffness index and change in FMD (r = -0.891; p eccentric exercise. In this study, acute high-intensity eccentric exercise increased central arterial stiffness; this increase was accompanied by a decrease in endothelial function caused by reduced endothelium-dependent vasodilation but not by a change in endothelium-dependent vasoconstriction.

  20. High-Intensity Interval Training as an Efficacious Alternative to Moderate-Intensity Continuous Training for Adults with Prediabetes

    Directory of Open Access Journals (Sweden)

    Mary E. Jung

    2015-01-01

    Full Text Available Aims. High-intensity interval training (HIIT leads to improvements in various markers of cardiometabolic health but adherence to HIIT following a supervised laboratory intervention has yet to be tested. We compared self-report and objective measures of physical activity after one month of independent exercise in individuals with prediabetes who were randomized to HIIT (n=15 or traditional moderate-intensity continuous training (MICT, n=17. Method. After completing 10 sessions of supervised training participants were asked to perform HIIT or MICT three times per week for four weeks. Results. Individuals in HIIT (89 ± 11% adhered to their prescribed protocol to a greater extent than individuals in MICT (71 ± 31% as determined by training logs completed over one-month follow-up (P = 0.05, Cohen’s d = 0.75. Minutes spent in vigorous physical activity per week measured by accelerometer were higher in HIIT (24 ± 18 as compared to MICT (11 ± 10 at one-month follow-up (P = 0.049, Cohen’s d = 0.92. Cardiorespiratory fitness and systolic blood pressure assessed at one-month follow-up were equally improved (P’s < 0.05. Conclusions. This study provides preliminary evidence that individuals with prediabetes can adhere to HIIT over the short-term and do so at a level that is greater than MICT.

  1. RADIATION DOSE MEASUREMENTS FOR HIGH-INTENSITY LASER INTERACTIONS WITH SOLID TARGETS AT SLAC.

    Science.gov (United States)

    Liang, T; Bauer, J; Cimeno, M; Ferrari, A; Galtier, E; Granados, E; Lee, H J; Liu, J; Nagler, B; Prinz, A; Rokni, S; Tran, H; Woods, M

    2016-12-01

    A systematic study of photon and neutron radiation doses generated in high-intensity laser-solid interactions is underway at SLAC National Accelerator Laboratory. These laser-solid experiments are being performed using a 25 TW (up to 1 J in 40 fs) femtosecond pulsed Ti:sapphire laser at the Linac Coherent Light Source's (LCLS) Matter in Extreme Conditions (MEC) facility. Radiation measurements were performed with passive and active detectors deployed at various locations inside and outside the target chamber. Results from radiation dose measurements for laser-solid experiments at SLAC MEC in 2014 with peak intensity between 10(18) and 7.1 × 10(19) W cm(-2) are presented.

  2. Radiation Dose Measurement for High-Intensity Laser Interactions with Solid Targets at SLAC

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Taiee [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-09-25

    A systematic study of photon and neutron radiation doses generated in high-intensity laser-solid interactions is underway at SLAC National Accelerator Laboratory. We found that these laser-solid experiments are being performed using a 25 TW (up to 1 J in 40 fs) femtosecond pulsed Ti:sapphire laser at the Linac Coherent Light Source’s (LCLS) Matter in Extreme Conditions (MEC) facility. Additionally, radiation measurements were performed with passive and active detectors deployed at various locations inside and outside the target chamber. Results from radiation dose measurements for laser-solid experiments at SLAC MEC in 2014 with peak intensity between 1018 to 7.1x1019 W/cm2 are presented.

  3. High-intensity drying processes-impulse drying

    Energy Technology Data Exchange (ETDEWEB)

    Orloff, D.I.

    1991-06-01

    Impulse drying is an innovative process for drying paper that holds great promise for reducing the energy consumed during the manufacture of paper and similar web products. impulse drying occurs when a wet paper web passes through a press nip in which one of the rolls is heated to a high temperature. A steam layer adjacent to the heated surface grows and displaces water from the sheet in a very efficient manner. The energy required for water removal is very much less than that required for conventional evaporative drying. To eliminate sheet delamination, low thermal mass ceramic press roll coatings were developed to reduce heat transfer to the sheet, while maintaining high heat flux during early stages of the process. In so doing, most of the transferred energy is used to form steam that displaces liquid water, rather than in excessively heating the sheet. During this period, a prototype ceramic coating was developed and its impulse drying performance was compared to that of steel surfaces. It was observed that ceramic platens can be operated at higher temperatures and pressures resulting in improved water removal and physical properties without inducing sheet delamination. Heat flux measurement techniques were developed to provide a mechanistic explanation for the superior performance of the prototype. The work confirmed that the prototype ceramic coating is more energy efficient than the steel surface.

  4. High-intensity drying processes-impulse drying. Yearly report

    Energy Technology Data Exchange (ETDEWEB)

    Orloff, D.I.

    1991-06-01

    Impulse drying is an innovative process for drying paper that holds great promise for reducing the energy consumed during the manufacture of paper and similar web products. impulse drying occurs when a wet paper web passes through a press nip in which one of the rolls is heated to a high temperature. A steam layer adjacent to the heated surface grows and displaces water from the sheet in a very efficient manner. The energy required for water removal is very much less than that required for conventional evaporative drying. To eliminate sheet delamination, low thermal mass ceramic press roll coatings were developed to reduce heat transfer to the sheet, while maintaining high heat flux during early stages of the process. In so doing, most of the transferred energy is used to form steam that displaces liquid water, rather than in excessively heating the sheet. During this period, a prototype ceramic coating was developed and its impulse drying performance was compared to that of steel surfaces. It was observed that ceramic platens can be operated at higher temperatures and pressures resulting in improved water removal and physical properties without inducing sheet delamination. Heat flux measurement techniques were developed to provide a mechanistic explanation for the superior performance of the prototype. The work confirmed that the prototype ceramic coating is more energy efficient than the steel surface.

  5. Efectos de la alcalosis metabólica inducida por la dieta en el rendimiento anaeróbico de alta intensidad Effects of the metabolic alkalosis induced by the diet in the high intensity anaerobic performance

    Directory of Open Access Journals (Sweden)

    O. Ríos Enríquez

    2010-10-01

    Full Text Available Objetivos: El propósito principal de este estudio es comparar el efecto de una alcalosis y acidosis inducidas por la dieta sobre el rendimiento en un esfuerzo anaeróbico láctico mantenido. Métodos: Para ello, trece sujetos activos se sometieron de forma cruzada a sendas dietas durante dos días y medio. Inmediatamente después realizaron una prueba de esfuerzo anaeróbica láctica máxima de estado estable hasta el agotamiento sobre cicloergómetro a 250 W. Resultados: La valoración de las dietas mostró una diferencia significativa en la excreción renal neta de ácidos (NAE estimada, así como un déficit calórico del 54% en la dieta alcalinizante, debido principalmente a una ingesta reducida de hidratos de carbono. En un 83% de los sujetos aumentó el pH urinario tras la dieta alcalinizante. El 77% incrementó sus niveles de lactato en sangre en la prueba tras la dieta alcalina. Los tiempos hasta la extenuación durante la prueba mejoraron o se mantuvieron en un 58% de los sujetos, siendo las mujeres las que mejor respondieron a la dieta con un 83% de casos. Conclusiones: Parece haber evidencias de mejora de rendimiento en esfuerzos de tipo anaeróbico láctico hasta el agotamiento de 60 s a 2 min de duración tras consumir una dieta con potencial alcalinizante.Objectives: The purpose of this study is to compare the effects of two diets, one acidifier and the other alkalizer, on the sport performance in an extreme anaerobic stress test. Methods: For that purpose thirteen individuals were subjected to two such diets in a crossed test for two and a half days. Immediately after, they were tested in a maximum lactic anaerobic stress test of stable state to exhaustion on an ergo-cycle at 250W. Results: The assessment of the diets yielded a significant difference in the estimated NAE (net acid excretion and a caloric deficit of 54% on the alkalizer diet, mainly due to a reduced ingestion of carbohydrates. The urinary pH increased by 83% for

  6. Advanced approaches to high intensity laser-driven ion acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Henig, Andreas

    2010-04-26

    Since the pioneering work that was carried out 10 years ago, the generation of highly energetic ion beams from laser-plasma interactions has been investigated in much detail in the regime of target normal sheath acceleration (TNSA). Creation of ion beams with small longitudinal and transverse emittance and energies extending up to tens of MeV fueled visions of compact, laser-driven ion sources for applications such as ion beam therapy of tumors or fast ignition inertial con finement fusion. However, new pathways are of crucial importance to push the current limits of laser-generated ion beams further towards parameters necessary for those applications. The presented PhD work was intended to develop and explore advanced approaches to high intensity laser-driven ion acceleration that reach beyond TNSA. In this spirit, ion acceleration from two novel target systems was investigated, namely mass-limited microspheres and nm-thin, free-standing diamond-like carbon (DLC) foils. Using such ultrathin foils, a new regime of ion acceleration was found where the laser transfers energy to all electrons located within the focal volume. While for TNSA the accelerating electric field is stationary and ion acceleration is spatially separated from laser absorption into electrons, now a localized longitudinal field enhancement is present that co-propagates with the ions as the accompanying laser pulse pushes the electrons forward. Unprecedented maximum ion energies were obtained, reaching beyond 0.5 GeV for carbon C{sup 6+} and thus exceeding previous TNSA results by about one order of magnitude. When changing the laser polarization to circular, electron heating and expansion were shown to be efficiently suppressed, resulting for the first time in a phase-stable acceleration that is dominated by the laser radiation pressure which led to the observation of a peaked C{sup 6+} spectrum. Compared to quasi-monoenergetic ion beam generation within the TNSA regime, a more than 40 times

  7. High-Intensity Training and Salivary Immunoglobulin A Responses in Professional Top-Level Soccer Players: Effect of Training Intensity.

    Science.gov (United States)

    Owen, Adam L; Wong, Del P; Dunlop, Gordon; Groussard, Carole; Kebsi, Wiem; Dellal, Alexandre; Morgans, Ryland; Zouhal, Hassane

    2016-09-01

    Owen, AL, Wong, DP, Dunlop, G, Groussard, C, Kebsi, W, Dellal, A, Morgans, R, and Zouhal, H. High-intensity training and salivary immunoglobulin A responses in professional top-level soccer players: Effect of training intensity. J Strength Cond Res 30(9): 2460-2469, 2016-This study aimed (a) to test the hypothesis that salivary immunoglobulin A (s-IgA) would vary with training intensity sessions (low-intensity [LI] vs. high-intensity sessions [HI]) during a traditional training program divided into 4 training periods and (b) to identify key variables (e.g., GPS data, rating of perceived exertion [RPE], and training duration), which could affect s-IgA. Saliva samples of 10 elite professional soccer players were collected (a) before the investigation started to establish the baseline level and (b) before and after each 4 training sessions (LI vs. HI). Training intensity was monitored as internal (through heart rate responses and RPE) and external (through GPS) loads. High-intensity sessions were associated with higher external load (GPS) and with higher RPE. Baseline and pretraining s-IgA did not differ between the 4 training sessions both for HI and LI. Post-training s-IgA were not different (in absolute value and in percentage of change) between HI and LI sessions at the first 3 periods. However, at the fourth period, s-IgA concentration for HI session was significantly lower (p ≤ 0.05) than the LI session. The percentage change between s-IgA post-training and s-IgA baseline concentrations differ significantly (p ≤ 0.05) between HI and LI training sessions. Significant correlations between s-IgA and training intensity were also noted. High-intensity soccer training sessions might cause a significant decrease in s-IgA values during the postexercise window as compared with LI sessions. This study encourages coaches to monitor s-IgA in routine, particularly during HI training periods, to take precautions to avoid upper respiratory tract infection in highly trained

  8. Effects of High-Intensity Blood Flow Restriction Exercise on Muscle Fatigue

    Directory of Open Access Journals (Sweden)

    Neto Gabriel R.

    2014-07-01

    Full Text Available Strength training combined with blood flow restriction (BFR have been used to improve the levels of muscle adaptation. The aim of this paper was to investigate the acute effect of high intensity squats with and without blood flow restriction on muscular fatigue levels. Twelve athletes (aged 25.95 ± 0.84 years were randomized into two groups: without Blood Flow Restriction (NFR, n = 6 and With Blood Flow Restriction (WFR, n = 6 that performed a series of free weight squats with 80% 1-RM until concentric failure. The strength of the quadriceps extensors was assessed in a maximum voluntary isometric contraction integrated to signals from the surface electromyogram. The average frequency showed significant reductions in the WFR group for the vastus lateralis and vastus medialis muscles, and intergroup only for the vastus medialis. In conclusion, a set of squats at high intensity with BFR could compromise muscle strength immediately after exercise, however, differences were not significant between groups.

  9. Current status of high-intensity focused ultrasound for the management of uterine adenomyosis

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Vincent Y. T. [Dept. of Obstetrics and Gynaecology, Queen Mary Hospital, The University of Hong Kong, Hong Kong (China)

    2017-04-15

    While high-intensity focused ultrasound has been used for some time in the management of uterine fibroids, its effectiveness and safety in managing adenomyosis is less well established. A literature review was performed of all eligible reports using this modality as a treatment for adenomyosis. Relevant publications were obtained from the PubMed electronic database from inception through March 2016. Eleven articles, including information from 1,150 treatments and follow-up data from 990 patients, were reviewed. High-intensity focused ultrasound appears to be effective and safe in the management of symptomatic adenomyosis, and can be considered as an alternative uterine-sparing option for women with this condition.

  10. High-intensity intermittent swimming improves cardiovascular health status for women with mild hypertension

    DEFF Research Database (Denmark)

    Mohr, Magni; Nordsborg, Nikolai Baastrup; Lindenskov, Annika

    2014-01-01

    To test the hypothesis that high-intensity swim training improves cardiovascular health status in sedentary premenopausal women with mild hypertension, sixty-two women were randomized into high-intensity (n = 21; HIT), moderate-intensity (n = 21; MOD), and control groups (n = 20; CON). HIT perfor...

  11. High-intensity exercise training for the prevention of type 2 diabetes mellitus.

    Science.gov (United States)

    Rynders, Corey A; Weltman, Arthur

    2014-02-01

    Aerobic exercise training and diet are recommended for the primary prevention of type 2 diabetes mellitus and cardiovascular disease. The American Diabetes Association (ADA) recommends that adults with prediabetes engage in ≥ 150 minutes per week of moderate activity and target a 7% weight loss. However, traditional moderate-intensity (MI) exercise training programs are often difficult to sustain for prediabetic adults; a commonly cited barrier to physical activity in this population is the "lack of time" to exercise. When matched for total energy expenditure, high-intensity (HI) exercise training has a lower overall time commitment compared with traditional low-intensity (LI) or MI exercise training. Several recent studies comparing HI exercise training with LI and MI exercise training reported that HI exercise training improves skeletal muscle metabolic control and cardiovascular function in a comparable and/or superior way relative to LI and MI exercise training. Although patients can accrue all exercise benefits by performing LI or MI activities such as walking, HI activities represent a time-efficient alternative to meeting physical activity guidelines. High-intensity exercise training is a potent tool for improving cardiometabolic risk for prediabetic patients with limited time and may be prescribed when appropriate.

  12. Influence of carbohydrate supplementation on plasma cytokine and neutrophil degranulation responses to high intensity intermittent exercise.

    Science.gov (United States)

    Bishop, Nicolette C; Gleeson, Michael; Nicholas, Ceri W; Ali, Ajmol

    2002-06-01

    Ingesting carbohydrate (CHO) beverages during prolonged, continuous heavy exercise results in smaller changes in the plasma concentrations of several cytokines and attenuates a decline in neutrophil function. In contrast, ingesting CHO during prolonged intermittent exercise appears to have negligible influence on these responses, probably due to the overall moderate intensity of these intermittent exercise protocols. Therefore, we examine the effect of CHO ingestion on plasma interleukin-6 (IL-6), tumor necrosis factor-alpha (TNF-alpha) and lipopolysaccharide (LPS)-stimulated neutrophil degranulation responses to high-intensity intermittent running. Six trained male soccer players performed 2 exercise trials, 7 days apart, in a randomized, counterbalanced design. On each occasion, they completed six 15-min periods of intermittent running consisting of maximal sprinting interspersed with less intense periods of running and walking. Subjects consumed either CHO or artificially sweetened placebo (PLA) beverages immediately before and at 15-min intervals during the exercise. At 30 min post-exercise, CHO versus PLA was associated with a higher plasma glucose concentration (p exercise, LPS-stimulated elastase release per neutrophil fell 31% below baseline values on the PLA trial (p = .06) compared with 17% on the CHO trial (p = .30). Plasma TNF-alpha concentration increased following the exercise (main effect of time, p attenuates changes in plasma IL-6 concentration, neutrophil trafficking, and LPS-stimulated neutrophil degranulation in response to intermittent exercise that involves bouts of very high intensity exercise.

  13. High-Intensity Femtosecond Laser Interaction with Rare Gas Clusters

    Institute of Scientific and Technical Information of China (English)

    林亚风; 钟钦; 曾淳; 陈哲

    2001-01-01

    With a 45 fs multiterawatt 790 nm laser system and jets of argon and krypton atomic clusters, a study of the interaction of fs intense laser pulses with large size rare gas dusters was conducted. The maximum laser intensity of about 7 × 1016 W/cm2 and dusters composed of thousands of atoms which were determined through Rayleigh scattering measurements were involved inthe experiments. On the one hand, the results indicate that the interaction is strongly cluster size dependent. The stronger the interaction, the larger the clusters are. On the other hand, a saturation followed by a drop of the energy of ions ejected from the interaction will occur when the laser intensity exceeds a definite value for clusters of a certain size.

  14. Effects and Sustainability of a 13-Day High-Intensity Shock Microcycle in Soccer

    Directory of Open Access Journals (Sweden)

    Patrick Wahl

    2014-06-01

    Full Text Available The preseason in soccer is a short period of 6-8 weeks where conditional abilities, technical and tactical elements need to be trained. Therefore, time is lacking to perform long term preparation periods for different abilities, especially endurance training. There is evidence that the implementation of high-intensity shock microcycles in preseason training could be one way to improve physical performance in a short period of time. Therefore, the purpose of the present study was to examine the effects and the sustainability of a high-intensity shock microcycle on soccer specific performance. Over 2 weeks, 12 male soccer players (26.1 ± 4.5 years performed 12 high-intensity training (HIT sessions in addition to their usual training. Before (pre, 6 days (6d and 25 days (25d after training, subjects performed Counter Movement Jump (CMJ, Repeated-Sprint Ability (RSA test and Yo-Yo Intermittent Recovery Test Level 2 (YYIR2. Mean sprint time (RSAMean (cohen’s d = -1.15, percentage decrement score (RSAIndex (cohen’s d = -1.99 and YYIR2 (cohen’s d = +1.92 improved significantly from pre to 6d. 25d after, values showed a significant reduction for YYIR2 (cohen’s d = -0.81 and small to moderate but not significant increase for RSAMean (cohen’s d = +0.37 and RSAIndex (cohen’s d = +0.7 compared to 6d values. Small but no significant increases were found for CMJ (cohen’s d = +0.33 and no significant and substantial changes were found for RSABest (cohen’s d = -0.07 from pre to 6d. For competitive soccer players, block periodization of HIT offers a promising way to largely improve RSA and YYIR2 in a short period of time. Despite moderate to large decreases in RSAIndex and YYIR2 performance in the 19 day period without HIT, values still remained significantly higher 25d after the last HIT session compared to pre-values. However, it might be necessary to include isolated high-intensity sessions after a HIT training block in order to maintain the

  15. The High Luminosity Challenge: potential and limitations of High Intensity High Brightness in the LHC and its injectors

    CERN Document Server

    De Maria, R; Banfi, D; Barranco, J; Bartosik, H; Benedetto, E; Bruce, R; Brüning, O; Calaga, R; Cerutti, F; Damerau, H; Esposito, L; Fartoukh, S; Fitterer, M; Garoby, R; Gilardoni, S; Giovannozzi, M; Goddard, B; Gorini, B; Hanke, K; Iadarola, G; Lamont, M; Meddahi, M; Métral, E; Mikulec, B; Mounet, N; Papaphilippou, Y; Pieloni, T; Redaelli, S; Rossi, L; Rumolo, G; Shaposhnikova, E; Sterbini, G; Todesco, E; Tomás, R; Zimmermann, F; Valishev, A

    2014-01-01

    High-intensity and high-brightness beams are key ingredients to maximize the LHC integrated luminosity and to exploit its full potential. This contribution describes the optimization of beam and machine parameters to maximize the integrated luminosity as seen by the LHC experiments, by taking into account the expected intensity and brightness reach of LHC itself and its injector chain as well as the capabilities of the detectors for next run and foreseen upgrade scenarios.

  16. Circulating adiponectin concentration and body composition are altered in response to high-intensity interval training.

    Science.gov (United States)

    Shing, Cecilia M; Webb, Jessica J; Driller, Matthew W; Williams, Andrew D; Fell, James W

    2013-08-01

    Adiponectin influences metabolic adaptations that would prove beneficial to endurance athletes, and yet to date there is little known about the response of adiponectin concentrations to exercise, and, in particular, the response of this hormone to training in an athlete population. This study aimed to determine the response of plasma adiponectin concentrations to acute exercise after 2 different training programs and to determine the influence of the training on body composition. Seven state-level representative rowers (age: 19 ± 1.2 years [mean ± SD], height: 1.77 ± 0.10 m, body mass: 74.0 ± 10.7 kg, VO2peak 62.1 ± 7.0 ml·kg·min) participated in the double-blind, randomized crossover investigation. Rowers performed an incremental graded exercise test before and after completing 4 weeks of high-intensity interval ergometer training and 4 weeks of traditional ergometer rowing training. Rowers' body composition was assessed at baseline and after each training program. Significant increases in plasma adiponectin concentration occurred in response to maximal exercise after completion of the high-intensity interval training (p = 0.016) but not after traditional ergometer rowing training (p = 0.69). The high-intensity interval training also resulted in significant increases in mean 4-minute power output (p = 0.002) and VO2peak (p = 0.05), and a decrease in body fat percentage (p = 0.022). Mean 4-minute power output, VO2peak, and body fat percentage were not significantly different after 4 weeks of traditional ergometer rowing training (p > 0.05). Four weeks of high-intensity interval training is associated with an increase in adiponectin concentration in response to maximal exercise and a reduction in body fat percentage. The potential for changes in adiponectin concentration to reflect positive training adaptations and athlete performance level should be further explored.

  17. Effect of different light intensities on performance, welfare and behavior of turkey poults

    Directory of Open Access Journals (Sweden)

    Hesham Mohammed

    2016-03-01

    Full Text Available Objective: Lighting requirements of birds have to be considered for choosing the optimal light intensity. Therefore, the experiment was carried out to study the effects of the different light intensities on performance, welfare and behavior of turkey poults. Materials and Methods: A total of 81 turkey poults aging 3 weeks were randomly selected and divided into three equal groups. The birds were subjected for 3 different light intensities (5, 25 and 50 lux with 12 h photoperiod in 3 separate rooms. The growth performance parameters of the poults were measured; the parameters were body weight (BW, average feed intake (FI, average body weight gain (ABWG, relative growth rate (RGR, and feed conversion ratio (FCR. Besides, blood parameters and behavioral characters were observed. Results: Our results revealed that poults reared in low intensity (5 lux had better performance (body weight gain, relative growth rate and feed intake. Also, final body weight was significantly higher in 5 lux. The cortisol level was lower in 5 lux than other 25 and 50 lux. Behavior of poults is affected by light intensities in our study, where feather preening, feather pecking and aggressive behaviors were significantly higher in birds housed in the highest intensity (50 lux. In the same way, drinking time was significantly higher in 25 lux. The poults tended to lay and rest on perches more under the lowest intensity (5 lux. Conclusion: It was concluded that, it is better to use moderate light intensity to improve previous parameters with avoiding abnormal behavior. [J Adv Vet Anim Res 2016; 3(1.000: 18-23

  18. Is Moderate Intensity Exercise Training Combined with High Intensity Interval Training More Effective at Improving Cardiorespiratory Fitness than Moderate Intensity Exercise Training Alone?

    Directory of Open Access Journals (Sweden)

    Brendon H. Roxburgh, Paul B. Nolan, Ryan M. Weatherwax, Lance C. Dalleck

    2014-09-01

    Full Text Available The purpose of this study was to compare the effectiveness of either continuous moderate intensity exercise training (CMIET alone vs. CMIET combined with a single weekly bout of high intensity interval training (HIIT on cardiorespiratory fitness. Twenty nine sedentary participants (36.3 ± 6.9 yrs at moderate risk of cardiovascular disease were recruited for 12 weeks of exercise training on a treadmill and cycle ergometer. Participants were randomised into three groups: CMIET + HIIT (n = 7; 8-12 x 60 sec at 100% VO2max, 150 sec active recovery, CMIET (n = 6; 30 min at 45-60% oxygen consumption reserve (VO2R and a sedentary control group (n = 7. Participants in the CMIET + HIIT group performed a single weekly bout of HIIT and four weekly sessions of CMIET, whilst the CMIET group performed five weekly CMIET sessions. Probabilistic magnitude-based inferences were determined to assess the likelihood that the true value of the effect represents substantial change. Relative VO2max increased by 10.1% (benefit possible relative to control in in the CMIET + HIIT group (32.7 ± 9.2 to 36.0 ± 11.5 mL·kg-1·min-1 and 3.9% (benefit possible relative to control in the CMIET group (33.2 ± 4.0 to 34.5 ± 6.1 mL·kg-1·min-1, whilst there was a 5.7% decrease in the control group (30.0 ± 4.6 to 28.3 ± 6.5 mL·kg-1·min-1. It was ‘unclear’ if a clinically significant difference existed between the effect of CMIET + HIIT and CMIET on the change in VO2max. Both exercising groups showed clinically meaningful improvements in VO2max. Nevertheless, it remains ‘unclear’ whether one type of exercise training regimen elicits a superior improvement in cardiorespiratory fitness relative to its counterpart.

  19. Success factors of energy management in energy-intensive industries : energy performance measurement

    OpenAIRE

    Sivill, Leena

    2011-01-01

    This thesis explores energy performance measurement in support of energy management in the energy-intensive industries. In general, performance measurement is used in management for raising awareness, evaluating performance, setting targets and offering decision support. These purposes also apply to energy management, defined here as the management of all activities related to the economic and responsible use of energy in an organisation. This thesis answers the following three questions...

  20. The effect of electromagnetic interference from mobile communication on the performance of intensive care ventilators.

    Science.gov (United States)

    Jones, R P; Conway, D H

    2005-08-01

    Electromagnetic interference produced by wireless communication can affect medical devices and hospital policies exist to address this risk. During the transfer of ventilated patients, these policies may be compromised by essential communication between base and receiving hospitals. Local wireless networks (e.g. Bluetooth) may reduce the 'spaghetti syndrome' of wires and cables seen on intensive care units, but also generate electromagnetic interference. The aim of this study was to investigate these effects on displayed and actual ventilator performance. Five ventilators were tested: Drager Oxylog 2000, BREAS LTV-1000, Respironics BiPAP VISION, Puritan Bennett 7200 and 840. Electromagnetic interference was generated by three devices: Simoco 8020 radio handset, Nokia 7210 and Nokia 6230 mobile phone, Nokia 6230 communicating via Bluetooth with a Palm Tungsten T Personal Digital Assistant. We followed the American National Standard Recommended Practice for On-Site, Ad Hoc Testing (ANSI C63) for electromagnetic interference. We used a ventilator tester, to simulate healthy adult lungs and measure ventilator performance. The communication device under test was moved in towards each ventilator from a distance of 1 m in six axes. Alarms or error codes on the ventilator were recorded, as was ventilator performance. All ventilators tested, except for the Respironics VISION, showed a display error when subjected to electromagnetic interference from the Nokia phones and Simoco radio. Ventilator performance was only affected by the radio which caused the Puritan Bennett 840 to stop functioning completely. The transfer ventilators' performance were not affected by radio or mobile phone, although the mobile phone did trigger a low-power alarm. Effects on intensive care ventilators included display reset, with the ventilator restoring normal display function within 2 s, and low-power/low-pressure alarms. Bluetooth transmission had no effect on the function of all the

  1. High-performance laboratories and cleanrooms

    Energy Technology Data Exchange (ETDEWEB)

    Tschudi, William; Sartor, Dale; Mills, Evan; Xu, Tengfang

    2002-07-01

    The California Energy Commission sponsored this roadmap to guide energy efficiency research and deployment for high performance cleanrooms and laboratories. Industries and institutions utilizing these building types (termed high-tech buildings) have played an important part in the vitality of the California economy. This roadmap's key objective to present a multi-year agenda to prioritize and coordinate research efforts. It also addresses delivery mechanisms to get the research products into the market. Because of the importance to the California economy, it is appropriate and important for California to take the lead in assessing the energy efficiency research needs, opportunities, and priorities for this market. In addition to the importance to California's economy, energy demand for this market segment is large and growing (estimated at 9400 GWH for 1996, Mills et al. 1996). With their 24hr. continuous operation, high tech facilities are a major contributor to the peak electrical demand. Laboratories and cleanrooms constitute the high tech building market, and although each building type has its unique features, they are similar in that they are extremely energy intensive, involve special environmental considerations, have very high ventilation requirements, and are subject to regulations--primarily safety driven--that tend to have adverse energy implications. High-tech buildings have largely been overlooked in past energy efficiency research. Many industries and institutions utilize laboratories and cleanrooms. As illustrated, there are many industries operating cleanrooms in California. These include semiconductor manufacturing, semiconductor suppliers, pharmaceutical, biotechnology, disk drive manufacturing, flat panel displays, automotive, aerospace, food, hospitals, medical devices, universities, and federal research facilities.

  2. Analysis of Compute Vs Retrieve Intensive Web Applications and Its Impact On The Performance Of A Web Server

    Directory of Open Access Journals (Sweden)

    Syed Mutahar Aaqib

    2012-01-01

    Full Text Available The World Wide Web (WWW has undergone remarkable change over the past few years, placing substantially heavy load on Web servers. Today’s web servers host web applications that demand high computational resources. Also some applications require heavy database retrieval processing, making server load even more critical. In this paper, performance of Apache web server running compute and retrieve-intensive web workloads is analyzed. Workload files implemented in three dynamic web programming technologies: PERL, PHP and Java Servlets are used with MySQL acting as a data source. Measurements are performed with the intent to analyze the impact of application workloads on the overall performance of the web server and determine which web technology yields better performance on Windows and Linux platforms. Experimental results depict that for both compute and retrieve intensive applications, PHP exhibits better performance than PERL and Java Servlets. A multiple linear regression model was also developed to predict the web server performance and to validate the experimental results. This regression model showed that for compute and retrieve intensive web applications, PHP exhibits better performance than Perl and Java Servlets.

  3. Proton Acceleration Drived by High-intensity Ultraviolet Laser

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The generation of energetic protons from a solid thin-foil by the interactions of ultra-short and intense laser pulses is investigated in numerous experiments in the last decade. The energetic proton beams are promising candidates for proton fast ignitor (PFI)

  4. Overview of novel photovoltaic conversion techniques at high intensity levels

    Science.gov (United States)

    Stirn, R. J.

    1978-01-01

    The paper describes several photovoltaic devices currently under development that can operate under light intensities considerably higher than can silicon solar cells. The technologies discussed include GaAs heteroface solar cells, multi-color systems, thermophotovoltaics, and laser energy conversion. Array costs for the GaAs and multi-color elements are estimated.

  5. Experimental Research at the Intensity Frontier in High Energy Physics

    Energy Technology Data Exchange (ETDEWEB)

    Marshak, Marvin L. [Univ. of Minnesota, Minneapolis, MN (United States)

    2014-06-30

    This Final Report describes DOE-supported Intensity Frontier research by the University of Minnesota during the interval April 1, 2011 to March 31, 2014. Primary activities included the MINOS, NOvA and LBNE Experiments and Heavy Quark studies at BES III.

  6. High-intensity knee extensor training restores skeletal muscle function in COPD patients.

    Science.gov (United States)

    Brønstad, Eivind; Rognmo, Oivind; Tjonna, Arnt Erik; Dedichen, Hans Henrich; Kirkeby-Garstad, Idar; Håberg, Asta K; Bjørk Ingul, Charlotte; Wisløff, Ulrik; Steinshamn, Sigurd

    2012-11-01

    Improving reduced skeletal muscle function is important for optimising exercise tolerance and quality of life in chronic obstructive pulmonary disease (COPD) patients. By applying high-intensity training to a small muscle group, we hypothesised a normalisation of muscle function. Seven patients with COPD performed 6 weeks (3 days·week(-1)) of high-intensity interval aerobic knee extensor exercise training. Five age-matched healthy individuals served as a reference group. Muscle oxygen uptake and mitochondrial respiration of the vastus lateralis muscle were measured before and after the 6-week training programme. Initial peak work and maximal mitochondrial respiration were reduced in COPD patients and improved significantly after the training programme. Peak power and maximal mitochondrial respiration in vastus lateralis muscle increased to the level of the control subjects and were mainly mediated via improved complex I respiration. Furthermore, when normalised to citrate synthase activity, no difference in maximal respiration was found either after the intervention or compared to controls, suggesting normal functioning mitochondrial complexes. The present study shows that high-intensity training of a restricted muscle group is highly effective in restoring skeletal muscle function in COPD patients.

  7. Architecture and Programming Models for High Performance Intensive Computation

    Science.gov (United States)

    2016-06-29

    SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 14 19a. NAME OF RESPONSIBLE PERSON Xiaoming Li a. REPORT b...identifying major concepts in the report. 16. SECURITY CLASSIFICATION. Enter security classification in accordance with security classification...release. Merge DNS     Simulator   PTV Camera   Comparison,   Analysis, and  Control Interac1ve   Visualiza1on   PTV Camera   PTV

  8. Reflectivity of plasmas created by high-intensity, ultra-short laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Gold, D.M.

    1994-06-01

    Experiments were performed to characterize the creation and evolution of high-temperature (T{sub e}{approximately}100eV), high-density (n{sub e}>10{sup 22}cm{sup {minus}3}) plasmas created with intense ({approximately}10{sup 12}-10{sup 16}W/cm{sup 2}), ultra-short (130fs) laser pulses. The principle diagnostic was plasma reflectivity at optical wavelengths (614nm). An array of target materials (Al, Au, Si, SiO{sub 2}) with widely differing electronic properties tested plasma behavior over a large set of initial states. Time-integrated plasma reflectivity was measured as a function of laser intensity. Space- and time-resolved reflectivity, transmission and scatter were measured with a spatial resolution of {approximately}3{mu}m and a temporal resolution of 130fs. An amplified, mode-locked dye laser system was designed to produce {approximately}3.5mJ, {approximately}130fs laser pulses to create and nonintrusively probe the plasmas. Laser prepulse was carefully controlled to suppress preionization and give unambiguous, high-density plasma results. In metals (Al and Au), it is shown analytically that linear and nonlinear inverse Bremsstrahlung absorption, resonance absorption, and vacuum heating explain time-integrated reflectivity at intensities near 10{sup 16}W/cm{sup 2}. In the insulator, SiO{sub 2}, a non-equilibrium plasma reflectivity model using tunneling ionization, Helmholtz equations, and Drude conductivity agrees with time-integrated reflectivity measurements. Moreover, a comparison of ionization and Saha equilibration rates shows that plasma formed by intense, ultra-short pulses can exist with a transient, non-equilibrium distribution of ionization states. All targets are shown to approach a common reflectivity at intensities {approximately}10{sup 16}W/cm{sup 2}, indicating a material-independent state insensitive to atomic or solid-state details.

  9. Block periodization of high-intensity aerobic intervals provides superior training effects in trained cyclists.

    Science.gov (United States)

    Rønnestad, B R; Hansen, J; Ellefsen, S

    2014-02-01

    The purpose of this study was to compare the effect of two different methods of organizing endurance training in trained cyclists. One group of cyclists performed block periodization, wherein the first week constituted five sessions of high-intensity aerobic training (HIT), followed by 3 weeks of one weekly HIT session and focus on low-intensity training (LIT) (BP; n = 10, VO2max  = 62 ± 2 mL/kg/min). Another group of cyclists performed a more traditional organization, with 4 weeks of two weekly HIT sessions interspersed with LIT (TRAD; n = 9, VO2max  = 63 ± 2 mL/kg/min). Similar volumes of both HIT and LIT was performed in the two groups. While BP increased VO2max , peak power output (Wmax) and power output at 2 mmol/L [la(-)] by 4.6 ± 3.7%, 2.1 ± 2.8%, and 10 ± 12%, respectively (P training compared with TRAD training (ES = 1.34, ES = 0.85, and ES = 0.71, respectively). The present study suggests that block periodization of training provides superior adaptations to traditional organization during a 4-week endurance training period, despite similar training volume and intensity. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Modeling and Validation of Performance Limitations for the Optimal Design of Interferometric and Intensity-Modulated Fiber Optic Displacement Sensors

    Energy Technology Data Exchange (ETDEWEB)

    Moro, Erik A. [Los Alamos National Laboratory

    2012-06-07

    Optical fiber sensors offer advantages over traditional electromechanical sensors, making them particularly well-suited for certain measurement applications. Generally speaking, optical fiber sensors respond to a desired measurand through modulation of an optical signal's intensity, phase, or wavelength. Practically, non-contacting fiber optic displacement sensors are limited to intensity-modulated and interferometric (or phase-modulated) methodologies. Intensity-modulated fiber optic displacement sensors relate target displacement to a power measurement. The simplest intensity-modulated sensor architectures are not robust to environmental and hardware fluctuations, since such variability may cause changes in the measured power level that falsely indicate target displacement. Differential intensity-modulated sensors have been implemented, offering robustness to such intensity fluctuations, and the speed of these sensors is limited only by the combined speed of the photodetection hardware and the data acquisition system (kHz-MHz). The primary disadvantages of intensity-modulated sensing are the relatively low accuracy (?m-mm for low-power sensors) and the lack of robustness, which consequently must be designed, often with great difficulty, into the sensor's architecture. White light interferometric displacement sensors, on the other hand, offer increased accuracy and robustness. Unlike their monochromatic-interferometer counterparts, white light interferometric sensors offer absolute, unambiguous displacement measurements over large displacement ranges (cm for low-power, 5 mW, sources), necessitating no initial calibration, and requiring no environmental or feedback control. The primary disadvantage of white light interferometric displacement sensors is that their utility in dynamic testing scenarios is limited, both by hardware bandwidth and by their inherent high-sensitivity to Doppler-effects. The decision of whether to use either an intensity

  11. Polarized training has greater impact on key endurance variables than threshold, high intensity or high volume training

    Directory of Open Access Journals (Sweden)

    Thomas eStöggl

    2014-02-01

    Full Text Available Endurance athletes integrate four conditioning concepts in their training programs: high-volume training (HVT, ‘threshold-training’ (THR, high-intensity interval training (HIIT and a combination of these aforementioned concepts known as polarized training (POL. The purpose of this study was to explore which of these four training concepts provides the greatest response on key components of endurance performance in well-trained endurance athletes. Methods: Forty eight runners, cyclists, triathletes and cross-country skiers (peak oxygen uptake: (VO2peak: 62.6±7.1 mL∙min-1∙kg-1 were randomly assigned to one of four groups performing over nine weeks. An incremental test, work economy and a VO2peak tests were performed. Training intensity was heart rate controlled. Results: POL demonstrated the greatest increase in VO2peak (+6.8 ml∙min∙kg-1 or 11.7%, P0.05. Conclusion: POL resulted in the greatest improvements in most key variables of endurance performance in well-trained endurance athletes. THR or HVT did not lead to further improvements in performance related variables.

  12. The high-producing dairy cow and its reproductive performance

    DEFF Research Database (Denmark)

    Dobson, H; Smith, Rf; Royal, Md;

    2007-01-01

    There is evidence that the reproductive performance of dairy cows has declined as milk yields have increased over the last 40 years. Identifying the precise cause(s) of this problem may provide focused solutions. Intensive genetic selection for very high yields has reduced fertility, due mainly t...

  13. High Performance Torso Cooling Garment

    Science.gov (United States)

    Conger, Bruce; Makinen, Janice

    2016-01-01

    The concept proposed in this paper is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area, which could facilitate removal of LCVG tubing from the arms and legs, thereby increasing suited crew member mobility. EVA space suit mobility in micro-gravity is challenging, and it becomes even more challenging in the gravity of Mars. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased. This increase in efficiency could provide the required liquid cooling via torso tubing only; no arm or leg LCVG tubing would be required. Benefits of this approach include increased crewmember mobility, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development. This report describes analysis and test activities performed to evaluate the potential improvements to the thermal performance of the LCVG. Analyses evaluated potential tube shapes for improving the thermal performance of the LCVG. The analysis results fed into the selection of flat flow strips to improve thermal contact with the skin of the suited test subject. Testing of small segments was performed to compare thermal performance of the tubing approach of the current LCVG to the flat flow strips proposed as the new concept. Results of the testing is presented along with recommendations for future development of this new concept.

  14. Learning Apache Solr high performance

    CERN Document Server

    Mohan, Surendra

    2014-01-01

    This book is an easy-to-follow guide, full of hands-on, real-world examples. Each topic is explained and demonstrated in a specific and user-friendly flow, from search optimization using Solr to Deployment of Zookeeper applications. This book is ideal for Apache Solr developers and want to learn different techniques to optimize Solr performance with utmost efficiency, along with effectively troubleshooting the problems that usually occur while trying to boost performance. Familiarity with search servers and database querying is expected.

  15. Understanding laser-solid interactions at ultra-high intensities

    Science.gov (United States)

    Murphy, C. D.; Gray, R. J.; Carroll, D. C.; MacLellan, D. A.; Powell, H.; Scott, G. G.; Ridgers, C. P.; Brady, C. S.; Neely, D.; Green, J. S.; Booth, N.; McKenna, P.

    2012-10-01

    The interaction of matter with lasers is a subject which has progressed rapidly over the last two decades as higher intensity lasers have opened the door to nonlinear and then relativistic interactions such that applications in ion acceleration and x-ray backlighting sources have become a clear possibility. Until recently, lasers capable of reaching the highest intensities (˜10^21 Wcm-2) have been glass-based systems with a low shot rate making detailed studies prohibitively time consuming. The development of petawatt-class Ti:Sapphire lasers such as Astra Gemini at STFC - Rutherford Appleton Laboratory, has made the systematic studies required to understand such interaction physics feasible. One such experiment on the Astra Gemini laser will be presented. The photon and particle diagnostics used will be explained and their results presented.

  16. High-Performance Composite Chocolate

    Science.gov (United States)

    Dean, Julian; Thomson, Katrin; Hollands, Lisa; Bates, Joanna; Carter, Melvyn; Freeman, Colin; Kapranos, Plato; Goodall, Russell

    2013-01-01

    The performance of any engineering component depends on and is limited by the properties of the material from which it is fabricated. It is crucial for engineering students to understand these material properties, interpret them and select the right material for the right application. In this paper we present a new method to engage students with…

  17. High-Performance Composite Chocolate

    Science.gov (United States)

    Dean, Julian; Thomson, Katrin; Hollands, Lisa; Bates, Joanna; Carter, Melvyn; Freeman, Colin; Kapranos, Plato; Goodall, Russell

    2013-01-01

    The performance of any engineering component depends on and is limited by the properties of the material from which it is fabricated. It is crucial for engineering students to understand these material properties, interpret them and select the right material for the right application. In this paper we present a new method to engage students with…

  18. High-performance electroabsorption modulator

    Science.gov (United States)

    Wei, Zhang; Jiaoqing, Pan; Hongliang, Zhu; Huan, Wang; Wei, Wang

    2009-09-01

    A 100-μm-long electroabsorption modulator monolithically integrated with passive waveguides at the input and output ports is fabricated through ion implantation induced quantum well intermixing, using only a two-step low-pressure metal-organic vapor phase epitaxial process. An InGaAsP/InGaAsP intra-step quantum well is introduced to the active region to improve the modulation properties. In the experiment high modulation speed and high extinction ratio are obtained simultaneously, the electrical-to-optical frequency response (E/O response) without any load termination reaches to 22 GHz, and extinction ration is as high as 16 dB.

  19. Study of a final focus system for high intensity beams

    Energy Technology Data Exchange (ETDEWEB)

    Henestroza, Enrique; Eylon, Shmuel; Roy, Prabir K.; Yu, Simon S.; Bieniosek, Frank M.; Shuman, Derek B.; Waldron, William L.

    2004-06-01

    The NTX experiment at the Heavy Ion Fusion Virtual National Laboratory is exploring the performance of neutralized final focus systems for high perveance heavy ion beams. The final focus scenario in an HIF driver consists of several large aperture quadrupole magnets followed by a drift section in which the beam space charge is neutralized by a plasma. This beam is required to hit a millimeter-sized target spot at the end of the drift section. The objective of the NTX experiments and associated theory and simulations is to study the various physical mechanisms that determine the final spot size (radius r{sub s}) at a given distance (f) from the end of the last quadrupole. In a fusion driver, f is the standoff distance required to keep the chamber wall and superconducting magnets properly protected. The NTX final quadrupole focusing system produces a converging beam at the entrance to the neutralized drift section where it focuses to a small spot. The final spot is determined by the conditions of the beam entering the quadrupole section, the beam dynamics in the magnetic lattice, and the plasma neutralization dynamics in the drift section. The main issues are the control of emittance growth due to high order fields from magnetic multipoles and image fields. In this paper, we will describe the theoretical and experimental aspects of the beam dynamics in the quadrupole lattice, and how these physical effects influence the final beam size. In particular, we present theoretical and experimental results on the dependence of final spot size on geometric aberrations and perveance.

  20. HIGH INTENSITY EXERCISE AND FLEXIBILITY OF THE LOWER LIMBS: DOSE-EFFECT STUDY

    Directory of Open Access Journals (Sweden)

    João Rafael Valentim-Silva

    Full Text Available ABSTRACT Introduction: Sports scientists have been studying the phenomenon involving different types of exercises and their influence on other activities. Stretching exercises have a negative influence on muscular strength and power output, as do high intensity or long duration cardiovascular training. Nevertheless, several studies have found the opposite to be true Nevertheless, few investigations have studied the opposite. Objective: To determine whether high intensity power exercise influences muscular flexibility in an acute manner. Methods: A sample of forty-three male and female young adults aged between 18 and 28 years, with a mean age of 22.88 + 3.04 years, who have practiced physical activity for at least six months. To determine flexibility, the sit-and-reach test was used. For the high intensity training, a 45º leg press was used. A 10-rep movement was performed at 85% of 1 RM, in both pre- and post-tests. Statistic analysis was conducted using the ANOVA and Scheffer's post-hoc tests, with a level of significance for differences of < 0.05. Results: Comparison of the pre- and post-tests proved to be statistically significant from the baseline from the fourth to the seventh repetitions. Conclusion: Strength exercises at 85% of 1RM seem to significantly increase range of motion in an acute manner, and the growth of this range of motion has a dose-effect response.

  1. Development of a cryogenic hydrogen microjet for high-intensity, high-repetition rate experiments

    Science.gov (United States)

    Kim, J. B.; Göde, S.; Glenzer, S. H.

    2016-11-01

    The advent of high-intensity, high-repetition-rate lasers has led to the need for replenishing targets of interest for high energy density sciences. We describe the design and characterization of a cryogenic microjet source, which can deliver a continuous stream of liquid hydrogen with a diameter of a few microns. The jet has been imaged at 1 μm resolution by shadowgraphy with a short pulse laser. The pointing stability has been measured at well below a mrad, for a stable free-standing filament of solid-density hydrogen.

  2. High performance Mo adsorbent PZC

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1998-10-01

    We have developed Mo adsorbents for natural Mo(n, {gamma}){sup 99}Mo-{sup 99m}Tc generator. Among them, we called the highest performance adsorbent PZC that could adsorb about 250 mg-Mo/g. In this report, we will show the structure, adsorption mechanism of Mo, and the other useful properties of PZC when you carry out the examination of Mo adsorption and elution of {sup 99m}Tc. (author)

  3. Salutary effects of high-intensity interval training in persons with elevated cardiovascular risk

    Science.gov (United States)

    Fleg, Jerome L.

    2016-01-01

    Although moderate-intensity continuous training (MICT) has been the traditional model for aerobic exercise training for over four decades, a growing body of literature has demonstrated equal if not greater improvement in aerobic capacity and similar beneficial effects on body composition, glucose metabolism, blood pressure, and quality of life from high-intensity interval training (HIIT). An advantage of HIIT over MICT is the shorter time required to perform the same amount of energy expenditure. The current brief review summarizes the effects of HIIT on peak aerobic capacity and cardiovascular risk factors in healthy adults and those with various cardiovascular diseases, including coronary artery disease, chronic heart failure, and post heart transplantation. PMID:27635241

  4. High intensity and reduced volume training attenuates stress and recovery levels in elite swimmers

    DEFF Research Database (Denmark)

    Elbe, Anne-Marie; Rasmussen, Camilla P; Nielsen, Glen

    2016-01-01

    for baseline values. No significant effects could be observed in sports-specific stress or sports-specific recovery. The results indicate that increasing training intensity and reducing training volume for 12 weeks can reduce general stress and increase general recovery levels in competitive swimmers.......This study investigated the effect of increased high-intensity interval training (HIT) at the expense of total training volume on the stress and recovery levels of elite swimmers. Forty-one elite swimmers participated in the study and were randomly assigned to either a HIT or a control group (CON......). Eleven swimmers did not complete the questionnaires. For 12 weeks both groups trained ~12 h per week. The amount of HIT was ~5 h vs. 1 h, and total distance was ~17 km vs. ~35 km per week for HIT and CON, respectively. HIT was performed as 6-10 × 10-30 s maximal effort interspersed by 2-4 min of rest...

  5. A single bout of high-intensity interval training improves motor skill retention in individuals with stroke

    DEFF Research Database (Denmark)

    Nepveu, Jean-Francois; Thiel, Alexander; Tang, Ada

    2017-01-01

    intensity is sufficient to induce neuroplastic changes and improve motor skill retention in patients with chronic stroke. METHODS: Twenty-two patients with different levels of motor impairment were recruited. On the first session, the effects of a maximal graded exercise test on corticospinal...... exercise test triggers only modest neuroplastic changes in patients with chronic stroke. However, a single bout of high-intensity interval training performed immediately after motor practice improves skill retention, which could potentially accelerate motor recovery in these individuals....

  6. Carpet Aids Learning in High Performance Schools

    Science.gov (United States)

    Hurd, Frank

    2009-01-01

    The Healthy and High Performance Schools Act of 2002 has set specific federal guidelines for school design, and developed a federal/state partnership program to assist local districts in their school planning. According to the Collaborative for High Performance Schools (CHPS), high-performance schools are, among other things, healthy, comfortable,…

  7. Perceived Effects of Emotion Intensity on Athletic Performance: A Contingency-Based Individualized Approach

    Science.gov (United States)

    Robazza, Claudio; Bortoli, Laura; Hanin, Yuri

    2006-01-01

    This study, based on the Individual Zones of Optimal Functioning model, examined the perceived effect of idiosyncratic emotions and bodily symptoms on athletic performance along the entire emotion-intensity range. The participants were 35 elite Italian athletes, 16 women and 19 men, competing in either figure skating or gymnastics. Idiosyncratic…

  8. Phonological Short-Term Memory, Working Memory and Foreign Language Performance in Intensive Language Learning

    Science.gov (United States)

    Kormos, Judit; Safar, Anna

    2008-01-01

    In our research we addressed the question what the relationship is between phonological short-term and working memory capacity and performance in an end-of-year reading, writing, listening, speaking and use of English test. The participants of our study were 121 secondary school students aged 15-16 in the first intensive language training year of…

  9. The effect of pre-cooling intensity on cooling efficiency and exercise performance

    NARCIS (Netherlands)

    Bogerd, N.; Perret, C.; Bogerd, C.P.; Rossi, R.M.; Daanen, H.A.M.

    2010-01-01

    Although pre-cooling is known to enhance exercise performance, the optimal cooling intensity is unknown. We hypothesized that mild cooling opposed to strong cooling circumvents skin vasoconstriction and thermogenesis, and thus improves cooling efficiency reflected in improved time to exhaustion. Eig

  10. Perceived Effects of Emotion Intensity on Athletic Performance: A Contingency-Based Individualized Approach

    Science.gov (United States)

    Robazza, Claudio; Bortoli, Laura; Hanin, Yuri

    2006-01-01

    This study, based on the Individual Zones of Optimal Functioning model, examined the perceived effect of idiosyncratic emotions and bodily symptoms on athletic performance along the entire emotion-intensity range. The participants were 35 elite Italian athletes, 16 women and 19 men, competing in either figure skating or gymnastics. Idiosyncratic…

  11. Application of the speed-duration relationship to normalize the intensity of high-intensity interval training.

    Directory of Open Access Journals (Sweden)

    Carrie Ferguson

    Full Text Available The tolerable duration of continuous high-intensity exercise is determined by the hyperbolic Speed-tolerable duration (S-tLIM relationship. However, application of the S-tLIM relationship to normalize the intensity of High-Intensity Interval Training (HIIT has yet to be considered, with this the aim of present study. Subjects completed a ramp-incremental test, and series of 4 constant-speed tests to determine the S-tLIM relationship. A sub-group of subjects (n = 8 then repeated 4 min bouts of exercise at the speeds predicted to induce intolerance at 4 min (WR4, 6 min (WR6 and 8 min (WR8, interspersed with bouts of 4 min recovery, to the point of exercise intolerance (fixed WR HIIT on different days, with the aim of establishing the work rate that could be sustained for 960 s (i.e. 4×4 min. A sub-group of subjects (n = 6 also completed 4 bouts of exercise interspersed with 4 min recovery, with each bout continued to the point of exercise intolerance (maximal HIIT to determine the appropriate protocol for maximizing the amount of high-intensity work that can be completed during 4×4 min HIIT. For fixed WR HIIT tLIM of HIIT sessions was 399±81 s for WR4, 892±181 s for WR6 and 1517±346 s for WR8, with total exercise durations all significantly different from each other (P0.050. However, there was significantly less high-intensity work completed during bouts 2 (153.5±40. 9 m, 3 (136.9±38.9 m, and 4 (136.7±39.3 m, compared with bout 1 (264.9±58.7 m; P>0.050. These data establish that WR6 provides the appropriate work rate to normalize the intensity of HIIT between subjects. Maximal HIIT provides a protocol which allows the relative contribution of the work rate profile to physiological adaptations to be considered during alternative intensity-matched HIIT protocols.

  12. Application of the speed-duration relationship to normalize the intensity of high-intensity interval training.

    Science.gov (United States)

    Ferguson, Carrie; Wilson, John; Birch, Karen M; Kemi, Ole J

    2013-01-01

    The tolerable duration of continuous high-intensity exercise is determined by the hyperbolic Speed-tolerable duration (S-tLIM) relationship. However, application of the S-tLIM relationship to normalize the intensity of High-Intensity Interval Training (HIIT) has yet to be considered, with this the aim of present study. Subjects completed a ramp-incremental test, and series of 4 constant-speed tests to determine the S-tLIM relationship. A sub-group of subjects (n = 8) then repeated 4 min bouts of exercise at the speeds predicted to induce intolerance at 4 min (WR4), 6 min (WR6) and 8 min (WR8), interspersed with bouts of 4 min recovery, to the point of exercise intolerance (fixed WR HIIT) on different days, with the aim of establishing the work rate that could be sustained for 960 s (i.e. 4×4 min). A sub-group of subjects (n = 6) also completed 4 bouts of exercise interspersed with 4 min recovery, with each bout continued to the point of exercise intolerance (maximal HIIT) to determine the appropriate protocol for maximizing the amount of high-intensity work that can be completed during 4×4 min HIIT. For fixed WR HIIT tLIM of HIIT sessions was 399±81 s for WR4, 892±181 s for WR6 and 1517±346 s for WR8, with total exercise durations all significantly different from each other (PHIIT, there was no difference in tLIM of each of the 4 bouts (Bout 1: 229±27 s; Bout 2: 262±37 s; Bout 3: 235±49 s; Bout 4: 235±53 s; P>0.050). However, there was significantly less high-intensity work completed during bouts 2 (153.5±40. 9 m), 3 (136.9±38.9 m), and 4 (136.7±39.3 m), compared with bout 1 (264.9±58.7 m; P>0.050). These data establish that WR6 provides the appropriate work rate to normalize the intensity of HIIT between subjects. Maximal HIIT provides a protocol which allows the relative contribution of the work rate profile to physiological adaptations to be considered during alternative intensity-matched HIIT protocols.

  13. Causative factors of high intensity areas identified by MRI in the pontine base

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Masaki; Takahashi, Akira [Nagoya Univ. (Japan). Faculty of Medicine; Arahata, Yutaka; Motegi, Yoshimasa

    1994-08-01

    High intensity areas in the pontine base were found more frequently in patients of group A who had multiple supratentorial high intensity areas smaller than 15 mm in size and of group B whose vertebral arteries were asymmetric on MR angiography, as compared to those who had none of the above findings of MRI and MR angiography. The high intensity areas of group A were often found bilaterally in the upper pons and those of group B were present unilaterally in the lower pons. Pontine high intensity areas were found frequently on the same side as the smaller vertebral artery in group B. Periventricular hyperintensity was more severe in group A than than in group B. These results suggest that high intensity lesions in the pontine base may conform with the following conditions: (1) multiple small high intensity areas in the supratentorium due to diffuse arteriosclerosis, and (2) asymmetry of the vertebral arteries inducing hemodynamic disorders. (author).

  14. High-performance solar collector

    Science.gov (United States)

    Beekley, D. C.; Mather, G. R., Jr.

    1979-01-01

    Evacuated all-glass concentric tube collector using air or liquid transfer mediums is very efficient at high temperatures. Collector can directly drive existing heating systems that are presently driven by fossil fuel with relative ease of conversion and less expense than installation of complete solar heating systems.

  15. High Performance JavaScript

    CERN Document Server

    Zakas, Nicholas

    2010-01-01

    If you're like most developers, you rely heavily on JavaScript to build interactive and quick-responding web applications. The problem is that all of those lines of JavaScript code can slow down your apps. This book reveals techniques and strategies to help you eliminate performance bottlenecks during development. You'll learn how to improve execution time, downloading, interaction with the DOM, page life cycle, and more. Yahoo! frontend engineer Nicholas C. Zakas and five other JavaScript experts -- Ross Harmes, Julien Lecomte, Steven Levithan, Stoyan Stefanov, and Matt Sweeney -- demonstra

  16. High performance Vernier racetrack resonators.

    Science.gov (United States)

    Boeck, Robert; Flueckiger, Jonas; Yun, Han; Chrostowski, Lukas; Jaeger, Nicolas A F

    2012-12-15

    We demonstrate record performance of series-coupled silicon racetrack resonators exhibiting the Vernier effect. Our device has an interstitial peak suppression (IPS) of 25.5 dB, which is 14.5 dB larger than previously reported results. We also demonstrate the relationship between the inter-ring gap distance and the IPS as well as the 3 dB bandwidth (BW) both theoretically and experimentally. Namely, we show that as the inter-ring gap distance increases, the IPS increases and the 3 dB BW decreases.

  17. Beam dynamics of mixed high intensity highly charged ion Beams in the Q/A selector

    Science.gov (United States)

    Zhang, X. H.; Yuan, Y. J.; Yin, X. J.; Qian, C.; Sun, L. T.; Du, H.; Li, Z. S.; Qiao, J.; Wang, K. D.; Zhao, H. W.; Xia, J. W.

    2017-06-01

    Electron cyclotron resonance (ECR) ion sources are widely used in heavy ion accelerators for their advantages in producing high quality intense beams of highly charged ions. However, it exists challenges in the design of the Q/A selection systems for mixed high intensity ion beams to reach sufficient Q/A resolution while controlling the beam emittance growth. Moreover, as the emittance of beam from ECR ion sources is coupled, the matching of phase space to post accelerator, for a wide range of ion beam species with different intensities, should be carefully studied. In this paper, the simulation and experimental results of the Q/A selection system at the LECR4 platform are shown. The formation of hollow cross section heavy ion beam at the end of the Q/A selector is revealed. A reasonable interpretation has been proposed, a modified design of the Q/A selection system has been committed for HIRFL-SSC linac injector. The features of the new design including beam simulations and experiment results are also presented.

  18. The effect of progressive high-intensity inspiratory muscle training and fixed high-intensity inspiratory muscle training on the asymmetry of diaphragm thickness in stroke patients.

    Science.gov (United States)

    Jung, Ju-Hyeon; Kim, Nan-Soo

    2015-10-01

    [Purpose] This study investigated the effects of progressive load and fixed load high-intensity inspiratory muscle training on the asymmetry of diaphragm thickness in stroke patients. [Subjects] Twenty-one stroke patients were assigned to one of three groups: progressive load high-intensity inspiratory muscle training (n = 8), fixed load high-intensity inspiratory muscle training (n = 6), and controls (n = 7). [Methods] The progressive load and fixed load high-intensity inspiratory muscle training participants undertook an exercise program for 20 minutes, three times weekly, for 6 weeks. After each session, diaphragm thickness was measured using ultrasonography. The diaphragm asymmetry ratio and diaphragm thickening ratio were standardized using a formula. [Results] After intervention, the diaphragm asymmetry ratio significantly differed among the three groups, and the diaphragm asymmetry ratio significantly increased in the control group. A significant increase was identified in the diaphragm thickening ratio within the progressive load and fixed load high-intensity inspiratory muscle training groups. [Conclusion] Progressive load and fixed load high-intensity inspiratory muscle training decreased the asymmetry of diaphragm thickness in stroke patients; this effect, in turn, increased the diaphragm thickening ratio in stroke patients. The two interventions examined here should be selectively applied to individuals in the clinical field.

  19. Reliability of telemetric electromyography and near-infrared spectroscopy during high-intensity resistance exercise.

    Science.gov (United States)

    Scott, Brendan R; Slattery, Katie M; Sculley, Dean V; Lockie, Robert G; Dascombe, Ben J

    2014-10-01

    This study quantified the inter- and intra-test reliability of telemetric surface electromyography (EMG) and near infrared spectroscopy (NIRS) during resistance exercise. Twelve well-trained young men performed high-intensity back squat exercise (12 sets at 70-90% 1-repetition maximum) on two occasions, during which EMG and NIRS continuously monitored muscle activation and oxygenation of the thigh muscles. Intra-test reliability for EMG and NIRS variables was generally higher than inter-test reliability. EMG median frequency variables were generally more reliable than amplitude-based variables. The reliability of EMG measures was not related to the intensity or number of repetitions performed during the set. No notable differences were evident in the reliability of EMG between different agonist muscles. NIRS-derived measures of oxyhaemoglobin, deoxyhaemoglobin and tissue saturation index were generally more reliable during single-repetition sets than multiple-repetition sets at the same intensity. Tissue saturation index was the most reliable NIRS variable. Although the reliability of the EMG and NIRS measures varied across the exercise protocol, the precise causes of this variability are not yet understood. However, it is likely that biological variation during multi-joint isotonic resistance exercise may account for some of the variation in the observed results.

  20. Intensity dependence in high-level facial expression adaptation aftereffect.

    Science.gov (United States)

    Hong, Sang Wook; Yoon, K Lira

    2017-06-14

    Perception of a facial expression can be altered or biased by a prolonged viewing of other facial expressions, known as the facial expression adaptation aftereffect (FEAA). Recent studies using antiexpressions have demonstrated a monotonic relation between the magnitude of the FEAA and adaptor extremity, suggesting that facial expressions are opponent coded and represented continuously from one expression to its antiexpression. However, it is unclear whether the opponent-coding scheme can account for the FEAA between two facial expressions. In the current study, we demonstrated that the magnitude of the FEAA between two facial expressions increased monotonically as a function of the intensity of adapting facial expressions, consistent with the predictions based on the opponent-coding model. Further, the monotonic increase in the FEAA occurred even when the intensity of an adapting face was too weak for its expression to be recognized. These results together suggest that multiple facial expressions are encoded and represented by balanced activity of neural populations tuned to different facial expressions.

  1. Enhancing gas-phase reaction in a plasma using high intensity and high power ultrasonic acoustic waves

    DEFF Research Database (Denmark)

    2010-01-01

    is absorbed into said plasma (104), and where a sound pressure level of said generated ultrasonic high intensity and high power acoustic waves (102) is at least substantially 140 dB and where an acoustic power of said generated ultrasonic high intensity and high power acoustic waves (102); is at least......This invention relates to enhancing a gas-phase reaction in a plasma comprising: creating plasma (104) by at least one plasma source (106), and wherein that the method further comprises: generating ultrasonic high intensity and high power acoustic waves (102) having a predetermined amount...... of acoustic energy by at least one ultrasonic high intensity and high power gas-jet acoustic wave generator (101), where said ultrasonic high intensity and high power acoustic waves are directed to propagate towards said plasma (104) so that at least a part of said predetermined amount of acoustic energy...

  2. Effect of light intensity on ovarian gene expression, reproductive performance and body weight of rabbit does.

    Science.gov (United States)

    Sun, Liangzhan; Wu, Zhenyu; Li, Fuchang; Liu, Lei; Li, Jinglin; Zhang, Di; Sun, Chaoran

    2017-08-01

    The objective of the experiment was to find the minimum light intensity which could improve reproduction by examining its effect on ovarian gene expression, reproductive performance and body weight of rabbit does with three different light intensities: 60 (L), 80 (M), and 100 (H)lx. A total of 144 Rex-rabbits submitted to a 49-day reproductive regimen were used in this study. Ovaries were collected and relative abundance of mRNA for ovarian proteins of interest was examined with real-time PCR. Amount of protein for proteins of interest was examined by immunohistochemistry. Reproductive performance and doe bodyweight of the first three consecutive reproductive periods after initiation of the light intensity treatments were evaluated. The results provided evidence that light intensity had no effect on relative abundance of estradiol receptor-α (ER-α), follicle stimulating hormone receptor (FSHR), luteinizing hormone receptor (LHR), gonadotropin releasing hormone receptor 1 (GnRHR1) and progesterone receptor (PGR) mRNA. The relative abundance of growth hormone receptor (GHR) mRNA was, however, greater in Group L than M and H (P0.05). The bodyweight of the does in Group L was greater than the other two groups at first insemination, second insemination and the second postpartum period (P0.05). These observations suggest that light intensity between 60 and 100lx has no effect on the reproductive performance of rabbit does, however, the amounts of GHR mRNA and growth hormone (GH) protein were affected and the greater light intensity had a negative effect on bodyweight between the time of the first insemination and the second partum period. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Effect of carbohydrate availability on time to exhaustion in exercise performed at two different intensities

    Directory of Open Access Journals (Sweden)

    A.E. Lima-Silva

    2009-05-01

    Full Text Available This study examined the effects of pre-exercise carbohydrate availability on the time to exhaustion for moderate and heavy exercise. Seven men participated in a randomized order in two diet and exercise regimens each lasting 3 days with a 1-week interval for washout. The tests were performed at 50% of the difference between the first (LT1 and second (LT2 lactate breakpoint for moderate exercise (below LT2 and at 25% of the difference between the maximal load and LT2 for heavy exercise (above LT2 until exhaustion. Forty-eight hours before each experimental session, subjects performed a 90-min cycling exercise followed by 5-min rest periods and a subsequent 1-min cycling bout at 125% VO2max/1-min rest periods until exhaustion to deplete muscle glycogen. A diet providing 10% (CHOlow or 65% (CHOmod energy as carbohydrates was consumed for 2 days until the day of the experimental test. In the exercise below LT2, time to exhaustion did not differ between the CHOmod and the CHOlow diets (57.22 ± 24.24 vs 57.16 ± 25.24 min. In the exercise above LT2, time to exhaustion decreased significantly from 23.16 ± 8.76 min on the CHOmod diet to 18.30 ± 5.86 min on the CHOlow diet (P < 0.05. The rate of carbohydrate oxidation, respiratory exchange ratio and blood lactate concentration were reduced for CHOlow only during exercise above LT2. These results suggest that muscle glycogen depletion followed by a period of a low carbohydrate diet impairs high-intensity exercise performance.

  4. Performance evaluation of intensity modulated optical OFDM system with digital baseband distortion.

    Science.gov (United States)

    Vanin, Evgeny

    2011-02-28

    Bit-Error-Ratio (BER) of intensity modulated optical orthogonal frequency division multiplexing (OFDM) system is analytically evaluated accounting for nonlinear digital baseband distortion in the transmitter and additive noise in the photo receiver. The nonlinear distortion that is caused by signal clipping and quantization is taken into consideration. The signal clipping helps to overcome the system performance limitation related to high peak-to-average power ratio (PAPR) of the OFDM signal and to minimize the value of optical power that is required for achieving specified BER. The signal quantization due to a limited bit resolution of the digital to analog converter (DAC) causes an optical power penalty in the case when the bit resolution is too low. By introducing an effective signal to noise ratio (SNR) the optimum signal clipping ratio, system BER and required optical power at the input to the receiver is evaluated for the OFDM system with multi-level quadrature amplitude modulation (QAM) applied to the optical signal subcarriers. Minimum required DAC bit resolution versus the size of QAM constellation is identified. It is demonstrated that the bit resolution of 7 and higher causes negligibly small optical power penalty at the system BER=10⁻³ when 256-QAM and a constellation of lower size is applied. The performance of the optical OFDM system is compared to the performance of the multi-level amplitude-shift keying (M-ASK) system for the same number of information bits transmitted per signal sample. It is demonstrated that in the case of the matched receiver the M-ASK system outperforms OFDM and requires 3-3.5 dB less of optical power at BER=10⁻³ when 1-4 data bits are transmitted per signal sample.

  5. Personalized metabolomics for predicting glucose tolerance changes in sedentary women after high-intensity interval training

    National Research Council Canada - National Science Library

    Kuehnbaum, Naomi L; Gillen, Jenna B; Gibala, Martin J; Britz-McKibbin, Philip

    2014-01-01

    High-intensity interval training (HIIT) offers a practical approach for enhancing cardiorespiratory fitness, however its role in improving glucose regulation among sedentary yet normoglycemic women remains unclear...

  6. Nakagami imaging for detecting thermal lesions induced by high-intensity focused ultrasound in tissue.

    Science.gov (United States)

    Rangraz, Parisa; Behnam, Hamid; Tavakkoli, Jahan

    2014-01-01

    High-intensity focused ultrasound induces focalized tissue coagulation by increasing the tissue temperature in a tight focal region. Several methods have been proposed to monitor high-intensity focused ultrasound-induced thermal lesions. Currently, ultrasound imaging techniques that are clinically used for monitoring high-intensity focused ultrasound treatment are standard pulse-echo B-mode ultrasound imaging, ultrasound temperature estimation, and elastography-based methods. On the contrary, the efficacy of two-dimensional Nakagami parametric imaging based on the distribution of the ultrasound backscattered signals to quantify properties of soft tissue has recently been evaluated. In this study, ultrasound radio frequency echo signals from ex vivo tissue samples were acquired before and after high-intensity focused ultrasound exposures and then their Nakagami parameter and scaling parameter of Nakagami distribution were estimated. These parameters were used to detect high-intensity focused ultrasound-induced thermal lesions. Also, the effects of changing the acoustic power of the high-intensity focused ultrasound transducer on the Nakagami parameters were studied. The results obtained suggest that the Nakagami distribution's scaling and Nakagami parameters can effectively be used to detect high-intensity focused ultrasound-induced thermal lesions in tissue ex vivo. These parameters can also be used to understand the degree of change in tissue caused by high-intensity focused ultrasound exposures, which could be interpreted as a measure of degree of variability in scatterer concentration in various parts of the high-intensity focused ultrasound lesion.

  7. High-intensity endurance training improves adiponectin mRNA and plasma concentrations.

    Science.gov (United States)

    Moghadasi, Mehrzad; Mohebbi, Hamid; Rahmani-Nia, Farhad; Hassan-Nia, Sadegh; Noroozi, Hamid; Pirooznia, Nazanin

    2012-04-01

    Adiponectin is an anti-inflammatory protein that reduced in obesity. Exercise training may reduce the adipose tissue (AT), although it is not well known whether exercise-induced change in AT, increases the adiponectin mRNA expression and plasma concentrations or not; therefore, the purpose of this study was to investigate the adiponectin mRNA and plasma concentrations in middle-aged men after 12 weeks high-intensity exercise training and after a week detraining. Sixteen sedentary overweight and obese middle-aged men (age 41.18 ± 6.1 years; ± SD) volunteered to participate in this study. The subjects were randomly assigned to training group (n = 8) or control group (n = 8). The training group performed endurance training 4 days a week for 12 weeks at an intensity corresponding to 75-80% individual maximum oxygen consumption for 45 min. After 12 weeks of training, subjects underwent a week of detraining. The results showed that the BMI as well as central and peripheral AT volume were decreased in the training group compared to the control group (P training group resulted in a significant increase (P training compared to the control group (P training group. In conclusion, high-intensity endurance training caused an increase adiponectin mRNA in obese middle-aged men.

  8. No Effect of Exercise Intensity on Appetite in Highly-Trained Endurance Women.

    Science.gov (United States)

    Howe, Stephanie M; Hand, Taryn M; Larson-Meyer, D Enette; Austin, Kathleen J; Alexander, Brenda M; Manore, Melinda M

    2016-04-18

    In endurance-trained men, an acute bout of exercise is shown to suppress post-exercise appetite, yet limited research has examined this response in women. The purpose of this study was to investigate the effect of exercise intensity on appetite and gut hormone responses in endurance-trained women. Highly-trained women (n = 15, 18-40 years, 58.4 ± 6.4 kg, VO2MAX = 55.2 ± 4.3 mL/kg/min) completed isocaloric bouts (500 kcals or 2093 kJ) of moderate-intensity (MIE, 60% VO2MAX) and high-intensity (HIE, 85% VO2MAX) treadmill running at the same time of day, following a similar 48-h diet/exercise period, and at least 1-week apart. Blood was drawn pre-exercise (baseline), immediately post-exercise and every 20-min for the next 60-min. Plasma concentrations of acylated ghrelin, PYY3-36, GLP-1 and subjective appetite ratings via visual analog scale (VAS) were assessed at each time point. Acylated ghrelin decreased (p = 0.014) and PYY3-36 and GLP-1 increased (p = 0.036, p appetite suppression. VAS ratings of hunger and desire to eat decreased immediately post-exercise (p = 0.0012, p = 0.0031, respectively), also indicating appetite suppression. There were no differences between exercise intensities for appetite hormones or VAS. Similar to males, post-exercise appetite regulatory hormones were altered toward suppression in highly-trained women and independent of energy cost of exercise. Results are important for female athletes striving to optimize nutrition for endurance performance.

  9. No Effect of Exercise Intensity on Appetite in Highly-Trained Endurance Women

    Directory of Open Access Journals (Sweden)

    Stephanie M. Howe

    2016-04-01

    Full Text Available In endurance-trained men, an acute bout of exercise is shown to suppress post-exercise appetite, yet limited research has examined this response in women. The purpose of this study was to investigate the effect of exercise intensity on appetite and gut hormone responses in endurance-trained women. Highly-trained women (n = 15, 18–40 years, 58.4 ± 6.4 kg, VO2MAX = 55.2 ± 4.3 mL/kg/min completed isocaloric bouts (500 kcals or 2093 kJ of moderate-intensity (MIE, 60% VO2MAX and high-intensity (HIE, 85% VO2MAX treadmill running at the same time of day, following a similar 48-h diet/exercise period, and at least 1-week apart. Blood was drawn pre-exercise (baseline, immediately post-exercise and every 20-min for the next 60-min. Plasma concentrations of acylated ghrelin, PYY3–36, GLP-1 and subjective appetite ratings via visual analog scale (VAS were assessed at each time point. Acylated ghrelin decreased (p = 0.014 and PYY3–36 and GLP-1 increased (p = 0.036, p < 0.0001 immediately post-exercise, indicating appetite suppression. VAS ratings of hunger and desire to eat decreased immediately post-exercise (p = 0.0012, p = 0.0031, respectively, also indicating appetite suppression. There were no differences between exercise intensities for appetite hormones or VAS. Similar to males, post-exercise appetite regulatory hormones were altered toward suppression in highly-trained women and independent of energy cost of exercise. Results are important for female athletes striving to optimize nutrition for endurance performance.

  10. VMware vSphere performance designing CPU, memory, storage, and networking for performance-intensive workloads

    CERN Document Server

    Liebowitz, Matt; Spies, Rynardt

    2014-01-01

    Covering the latest VMware vSphere software, an essential book aimed at solving vSphere performance problems before they happen VMware vSphere is the industry's most widely deployed virtualization solution. However, if you improperly deploy vSphere, performance problems occur. Aimed at VMware administrators and engineers and written by a team of VMware experts, this resource provides guidance on common CPU, memory, storage, and network-related problems. Plus, step-by-step instructions walk you through techniques for solving problems and shed light on possible causes behind the problems. Divu

  11. High performance soft magnetic materials

    CERN Document Server

    2017-01-01

    This book provides comprehensive coverage of the current state-of-the-art in soft magnetic materials and related applications, with particular focus on amorphous and nanocrystalline magnetic wires and ribbons and sensor applications. Expert chapters cover preparation, processing, tuning of magnetic properties, modeling, and applications. Cost-effective soft magnetic materials are required in a range of industrial sectors, such as magnetic sensors and actuators, microelectronics, cell phones, security, automobiles, medicine, health monitoring, aerospace, informatics, and electrical engineering. This book presents both fundamentals and applications to enable academic and industry researchers to pursue further developments of these key materials. This highly interdisciplinary volume represents essential reading for researchers in materials science, magnetism, electrodynamics, and modeling who are interested in working with soft magnets. Covers magnetic microwires, sensor applications, amorphous and nanocrystalli...

  12. High performance polyethylene nanocomposite fibers

    Directory of Open Access Journals (Sweden)

    A. Dorigato

    2012-12-01

    Full Text Available A high density polyethylene (HDPE matrix was melt compounded with 2 vol% of dimethyldichlorosilane treated fumed silica nanoparticles. Nanocomposite fibers were prepared by melt spinning through a co-rotating twin screw extruder and drawing at 125°C in air. Thermo-mechanical and morphological properties of the resulting fibers were then investigated. The introduction of nanosilica improved the drawability of the fibers, allowing the achievement of higher draw ratios with respect to the neat matrix. The elastic modulus and creep stability of the fibers were remarkably improved upon nanofiller addition, with a retention of the pristine tensile properties at break. Transmission electronic microscope (TEM images evidenced that the original morphology of the silica aggregates was disrupted by the applied drawing.

  13. Influence of music on performance and psychophysiological responses during moderate-intensity exercise preceded by fatigue.

    Science.gov (United States)

    Lopes-Silva, Joao P; Lima-Silva, Adriano E; Bertuzzi, Romulo; Silva-Cavalcante, Marcos D

    2015-02-01

    We examined the effects of listening to music on time to exhaustion and psychophysiological responses during moderate-intensity exercise performed in fatigued and non-fatigued conditions. Fourteen healthy men performed moderate-intensity exercise (60% Wmax) until exhaustion under four different conditions: with and without pre-fatigue (induced by 100 drop jumps) and listening and not listening to music. Time to exhaustion was lower in the fatigued than the non-fatigued condition regardless listening to music. Similarly, RPE was higher in the fatigued than the non-fatigued condition, but music had no effect. On the other hand, listening to music decreased the associative thoughts regardless of fatigue status. Heart rate was not influenced by any treatment. These results suggest that listening to music changes attentional focus but is not able to reverse fatigue-derived alteration of performance. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Towards phasing using high X-ray intensity

    Directory of Open Access Journals (Sweden)

    Lorenzo Galli

    2015-11-01

    Full Text Available X-ray free-electron lasers (XFELs show great promise for macromolecular structure determination from sub-micrometre-sized crystals, using the emerging method of serial femtosecond crystallography. The extreme brightness of the XFEL radiation can multiply ionize most, if not all, atoms in a protein, causing their scattering factors to change during the pulse, with a preferential `bleaching' of heavy atoms. This paper investigates the effects of electronic damage on experimental data collected from a Gd derivative of lysozyme microcrystals at different X-ray intensities, and the degree of ionization of Gd atoms is quantified from phased difference Fourier maps. A pattern sorting scheme is proposed to maximize the ionization contrast and the way in which the local electronic damage can be used for a new experimental phasing method is discussed.

  15. The risk of retina damage from high intensity light sources.

    Science.gov (United States)

    Pollak, V A; Romanchuk, K G

    1980-05-01

    The risk of thermal damage to the retina of the eye by exposure to excessive light intensities from continuous and pulsed man-made sources is discussed. The probability of injury increases, the larger the radiant power absorbed by the retina and the smaller the size of the retinal image of the source. A mehtod of estimating the temperature increase of the immediately affected area of the retina is presented. The time constants involved are also briefly considered. Using numerical values from literature for the relevant parameters of the eye, threshold values for a variety of conditions can be established. Below these values little risk of retina damage should exist. The degree of hazard when these values are exceeded depends upon the circumstances. A case study of a welding accident showed good agreement between the conclusions of the theoretical analysis and clinical findings.

  16. Transverse feedback: high intensity operation, AGC, IGC, lessons for 2012

    CERN Document Server

    Höfle, W

    2012-01-01

    The transverse damper system (ADT) plays an important role in the preservation of the beam transverse emittance and for damping of oscillations driven by the coupled bunch instability. An overview of the ADT system will be presented with an emphasis on the important feedback loop parameters as they change from injection through the ramp into collision. The dedicated setting - up procedure required for the different bunch intensities and bunch spacings will be explained. During the 2011 run the injection and abort gap cleaning became operational at injection energy. Preparations for cleaning at 3.5 TeV as well as batch selective transverse blow - up were completed and preliminarily tested. Plans for 2012 include study and potential improvement of the system impulse response to improve the 'selectivity' of the cleaning and blow - up facility. The ADT also provides bunch - by - bunch observation, which was extensively used during the run and MDs, and will be further upgraded during the next year.

  17. High-Performance Image Synthesis for Radio Interferometry

    CERN Document Server

    Muscat, Daniel

    2014-01-01

    A radio interferometer indirectly measures the intensity distribution of the sky over the celestial sphere. Since measurements are made over an irregularly sampled Fourier plane, synthesising an intensity image from interferometric measurements requires substantial processing. Furthermore there are distortions that have to be corrected. In this thesis, a new high-performance image synthesis tool (imaging tool) for radio interferometry is developed. Implemented in C++ and CUDA, the imaging tool achieves unprecedented performance by means of Graphics Processing Units (GPUs). The imaging tool is divided into several components, and the back-end handling numerical calculations is generalised in a new framework. A new feature termed compression arbitrarily increases the performance of an already highly efficient GPU-based implementation of the w-projection algorithm. Compression takes advantage of the behaviour of oversampled convolution functions and the baseline trajectories. A CPU-based component prepares data ...

  18. HIGH-PERFORMANCE COATING MATERIALS

    Energy Technology Data Exchange (ETDEWEB)

    SUGAMA,T.

    2007-01-01

    Corrosion, erosion, oxidation, and fouling by scale deposits impose critical issues in selecting the metal components used at geothermal power plants operating at brine temperatures up to 300 C. Replacing these components is very costly and time consuming. Currently, components made of titanium alloy and stainless steel commonly are employed for dealing with these problems. However, another major consideration in using these metals is not only that they are considerably more expensive than carbon steel, but also the susceptibility of corrosion-preventing passive oxide layers that develop on their outermost surface sites to reactions with brine-induced scales, such as silicate, silica, and calcite. Such reactions lead to the formation of strong interfacial bonds between the scales and oxide layers, causing the accumulation of multiple layers of scales, and the impairment of the plant component's function and efficacy; furthermore, a substantial amount of time is entailed in removing them. This cleaning operation essential for reusing the components is one of the factors causing the increase in the plant's maintenance costs. If inexpensive carbon steel components could be coated and lined with cost-effective high-hydrothermal temperature stable, anti-corrosion, -oxidation, and -fouling materials, this would improve the power plant's economic factors by engendering a considerable reduction in capital investment, and a decrease in the costs of operations and maintenance through optimized maintenance schedules.

  19. Locomotor muscle fatigue does not alter oxygen uptake kinetics during high-intensity exercise

    Directory of Open Access Journals (Sweden)

    James Hopker

    2016-10-01

    Full Text Available The slow component (VO2sc that develops during high-intensity aerobic exercise is thought to be strongly associated with locomotor muscle fatigue. We sought to experimentally test this hypothesis by pre-fatiguing the locomotor muscles used during subsequent high-intensity cycling exercise. Over two separate visits, eight healthy male participants were asked to either perform a non-metabolically stressful 100 intermittent drop-jumps protocol (pre fatigue condition or rest for 33 minutes (control condition according to a random and counterbalanced order. Locomotor muscle fatigue was quantified with 6-second maximal sprints at a fixed pedaling cadence of 90 rev·min-1. Oxygen kinetics and other responses (heart rate, capillary blood lactate concentration and rating of perceived exertion, RPE were measured during two subsequent bouts of 6 min cycling exercise at 50% of the delta between the lactate threshold and VO2max determined during a preliminary incremental exercise test. All tests were performed on the same cycle ergometer. Despite significant locomotor muscle fatigue (P = 0.03, the VO2sc was not significantly different between the pre fatigue (464 ± 301 mL·min-1 and the control (556 ± 223 mL·min-1 condition (P = 0.50. Blood lactate response was not significantly different between conditions (P = 0.48 but RPE was significantly higher following the pre-fatiguing exercise protocol compared with the control condition (P < 0.01 suggesting higher muscle recruitment. These results demonstrate experimentally that locomotor muscle fatigue does not significantly alter the VO2 kinetic response to high intensity aerobic exercise, and challenge the hypothesis that the VO2sc is strongly associated with locomotor muscle fatigue.

  20. Psychology and socioculture affect injury risk, response, and recovery in high-intensity athletes: a consensus statement.

    Science.gov (United States)

    Wiese-Bjornstal, D M

    2010-10-01

    This consensus statement summarizes key contemporary research themes relevant to understanding the psychology and socioculture of sport injury. Special consideration is given toward high-intensity sport in which elite athlete training and performance efforts are characterized by explosive physical speed and strength, mental fortitude to push physical limits, and maximum effort and commitment to highly challenging goals associated with achieving exceptional performance. Sport injury occurrence in high-intensity sport is an adverse and stressful health event associated with a complex multitude of risks, consequences and outcomes. A biopsychosocial (Engel, 1980) view is advocated which contextualizes an understanding of the psychological aspects of sport injury in light of influential sociocultural, ethical, and biomedical issues. Outcomes related to athlete health and performance excellence are of equal importance in considering how psychological scholarship, expertise and services can be used to improve efforts focused on the prevention and management of sport injury among high-intensity athletes. The consensus view is that psychology and socioculture do affect sport injury risk, response and recovery in high-intensity athletes, and that continued efforts in psychological research and professional practice are needed to protect athlete physical and mental health and contribute toward performance excellence and career longevity.

  1. High-intensity endurance training increases nocturnal heart rate variability in sedentary participants.

    Science.gov (United States)

    Nummela, A; Hynynen, E; Kaikkonen, P; Rusko, H

    2016-03-01

    The effects of endurance training on endurance performance characteristics and cardiac autonomic modulation during night sleep were investigated during two 4-week training periods. After the first 4-week training period (3 x 40 min per week, at 75% of HRR) the subjects were divided into HIGH group (n = 7), who performed three high-intensity endurance training sessions per week; and CONTROL group (n = 8) who did not change their training. An incremental treadmill test was performed before and after the two 4-week training periods. Furthermore, nocturnal RR-intervals were recorded after each training day. In the second 4-week training period HIGH group increased their VO2max (P = 0.005) more than CONTROL group. At the same time, nocturnal HR decreased (P = 0.039) and high-frequency power (HFP) increased (P = 0.003) in HIGH group while no changes were observed in CONTROL group. Furthermore, a correlation was observed between the changes in nocturnal HFP and changes in VO2max during the second 4-week training period (r = 0.90, P sedentary subjects suggesting that nocturnal HFP can provide a useful method in monitoring individual responses to endurance training.

  2. High-intensity endurance training increases nocturnal heart rate variability in sedentary participants

    Directory of Open Access Journals (Sweden)

    A Nummela

    2016-01-01

    Full Text Available The effects of endurance training on endurance performance characteristics and cardiac autonomic modulation during night sleep were investigated during two 4-week training periods. After the first 4-week training period (3 x 40 min per week, at 75% of HRR the subjects were divided into HIGH group (n = 7, who performed three high-intensity endurance training sessions per week; and CONTROL group (n = 8 who did not change their training. An incremental treadmill test was performed before and after the two 4-weektraining periods. Furthermore, nocturnal RR-intervals were recorded after each training day. In the second 4-weektraining period HIGH group increased their V0Zmax (P = 0.005 more than CONTROL group. At the same time, nocturnal HR decreased (P = 0.039 and high-frequency power (HFP increased (P = 0.003 in HIGH group while no changes were observed in CONTROL group. Furthermore, a correlation was observed between the changes in nocturnal HFP and changes in V0Zmax during the second 4-week training period (r = 0.90, P < 0.001. The present study showed that the increased HFP is related to improved VO2max in sedentary subjects suggesting that nocturnal HFP can provide a useful method in monitoring individual responses to endurance training.

  3. High-intensity training reduces CD8+ T-cell redistribution in response to exercise

    NARCIS (Netherlands)

    Witard, O.C.; Turner, J.E.; Jackman, S.R.; Tipton, K.D.; Jeukendrup, A.E.; Kies, A.K.; Bosch, J.A.

    2012-01-01

    Purpose: We examined whether exercise-induced lymphocytosis and lymphocytopenia are impaired with high-intensity training. Methods: Eight trained cyclists (V·O2max = 64.2 ± 6.5 mL·kg-1·min-1) undertook 1 wk of normal-intensity training and a second week of high-intensity training. On day 7 of each w

  4. High Harmonic Radiation Generation and Attosecond pulse generation from Intense Laser-Solid Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Alexander Roy [Univ. of Michigan, Ann Arbor, MI (United States); Krushelnick, Karl [Univ. of Michigan, Ann Arbor, MI (United States)

    2016-09-08

    We have studied ion motion effects in high harmonic generation, including shifts to the harmonics which result in degradation of the attosecond pulse train, and how to mitigate them. We have examined the scaling with intensity of harmonic emission. We have also switched the geometry of the interaction to measure, for the first time, harmonics from a normal incidence interaction. This was performed by using a special parabolic reflector with an on axis hole and is to allow measurements of the attosecond pulses using standard techniques. Here is a summary of the findings: First high harmonic generation in laser-solid interactions at 1021 Wcm-2, demonstration of harmonic focusing, study of ion motion effects in high harmonic generation in laser-solid interactions, and demonstration of harmonic amplification.

  5. Intensity profile during an ultra-endurance triathlon in relation to testing and performance.

    Science.gov (United States)

    Barrero, A; Chaverri, D; Erola, P; Iglesias, X; Rodríguez, F A

    2014-12-01

    We examined the heart rate (HR)-based intensity profile during an ultra-endurance triathlon (UET) estimated from the individual HR-oxygen uptake (˙VO2) relationship during specific graded tests, relating it to race performance. 9 male ultra-endurance triathletes completed the study. Before racing, subjects performed graded exercise tests involving cycle (C) ergometry, treadmill running (R) and free swimming (S) for peak ˙VO2 and HR at ventilatory thresholds (VT). Exercise-specific HR-˙VO2 regression equations were developed. Mean race HR was higher during S (149.2 (10.1) bpm) than during C (137.1 (5.7) bpm) and R (136.2 (10.5) bpm). During C and R, HR was below both VT (11% and 27-28%). HR differences between S and C correlated with C, R and final times. The greatest differences between S and C were related to the worst times in the next stages. These ultra-endurance triathletes performed S at a higher relative intensity, which was inversely correlated with performance in the following stages. The best predictors of final racing time (81%) were weight-adjusted ˙VO2max and HR difference between C and S. A more adequate characterization of the time pattern during the whole race, especially during S, adds new information concerning the intensity profile and cardiovascular demands of an UET race.

  6. Amino acid supplements and recovery from high-intensity resistance training.

    Science.gov (United States)

    Sharp, Carwyn P M; Pearson, David R

    2010-04-01

    The purpose of this study was to investigate whether short-term amino acid supplementation could maintain a short-term net anabolic hormonal profile and decrease muscle cell damage during a period of high-intensity resistance training (overreaching), thereby enhancing recovery and decreasing the risk of injury and illness. Eight previously resistance trained males were randomly assigned to either a high branched chain amino acids (BCAA) or placebo group. Subjects consumed the supplement for 3 weeks before commencing a fourth week of supplementation with concomitant high-intensity total-body resistance training (overreaching) (3 x 6-8 repetitions maximum, 8 exercises). Blood was drawn prior to and after supplementation, then again after 2 and 4 days of training. Serum was analyzed for testosterone, cortisol, and creatine kinase. Serum testosterone levels were significantly higher (p creatine kinase levels were significantly lower (p resistance training. These findings suggest that short-term amino acid supplementation, which is high in BCAA, may produce a net anabolic hormonal profile while attenuating training-induced increases in muscle tissue damage. Athletes' nutrient intake, which periodically increases amino acid intake to reflect the increased need for recovery during periods of overreaching, may increase subsequent competitive performance while decreasing the risk of injury or illness.

  7. Noise of High Performance Aircraft at Afterburner

    Science.gov (United States)

    2016-02-10

    the large turbulence structures of the jet flow. Prior to this project, the principal investigator and his coworkers were the first to establish...distributed both in space and time. To perform this type of simulation, first, it is necessary to develop a stochastic boundary condition that generates a...field of randomly spaced hot and cold spots as input to the computation. The field of hot and cold blobs is characterized by a specified intensity

  8. Success factors of energy management in energy-intensive industries. Energy performance measurement

    Energy Technology Data Exchange (ETDEWEB)

    Sivill, L.

    2011-10-15

    This thesis explores energy performance measurement in support of energy management in the energy-intensive industries. In general, performance measurement is used in management for raising awareness, evaluating performance, setting targets and offering decision support. These purposes also apply to energy management, defined here as the management of all activities related to the economic and responsible use of energy in an organisation. This thesis answers the following three questions: 1) what is the concept of energy performance in a business organisation? 2) what is the importance of energy performance measurement to energy management in the energy-intensive industries? and 3) what are the subsequent needs for future research and development? A variety of methods are used, ranging from qualitative research to the modelling of energy systems and case demonstrations. The findings indicate that energy management should focus on improving energy performance, not energy efficiency, because this broader view is able to capture both the operational and strategic perspectives of energy management. This is in line with the trends of managerial integration and the adoption of sustainable development into management practice. The domain of energy performance indicators should entail organisational, systemic and temporal dimensions. From the perspective of operational management, performance measurement should address all the three means to improve energy performance, namely technology, operation and process integration. In addition to the operational management, future research and development should define the role of energy performance measurement in all the other management functions. These recommendations provide a wide spectrum of opportunities for the development of energy performance indicators, energy performance measurement systems and their underlying deployment processes in different industrial sectors, organisations and systems. (orig.)

  9. Scheduling in high performance buffered crossbar switches

    NARCIS (Netherlands)

    Mhamdi, L.

    2007-01-01

    High performance routers are the basic building blocks of the Internet. Most high performance routers built today use crossbars and a centralized scheduler. Due to their high scheduling complexity, crossbar-based routers are not scalable and cannot keep pace with the explosive growth of the Internet

  10. Dose-Response of High-Intensity Training (HIT on Atheroprotective miRNA-126 Levels

    Directory of Open Access Journals (Sweden)

    Boris Schmitz

    2017-05-01

    Full Text Available Aim: MicroRNA-126 (miR-126 exerts beneficial effects on vascular integrity, angiogenesis, and atherosclerotic plaque stability. The purpose of this investigation was to analyze the dose-response relationship of high-intensity interval training (HIIT on miR-126-3p and -5p levels.Methods: Sixty-one moderately trained individuals (females = 31 [50.8%]; 22.0 ± 1.84 years were consecutively recruited and allocated into three matched groups using exercise capacity. During a 4-week intervention a HIIT group performed three exercise sessions/week of 4 × 30 s at maximum speed (all-out, a progressive HIIT (proHIIT group performed three exercise sessions/week of 4 × 30 s at maximum speed (all-out with one extra session every week (up to 7 × 30 s and a low-intensity training (LIT control group performed three exercise sessions/week for 25 min <75% of maximum heart rate. Exercise miR-126-3p/-5p plasma levels were determined using capillary blood from earlobes.Results: No exercise-induced increase in miR-126 levels was detected at baseline, neither in the LIT (after 25 min low-intensity running nor the HIIT groups (after 4 min of high-intensity running. After the intervention, the LIT group presented an increase in miR-126-3p, while in the HIIT group, miR-126-3p levels were still reduced (all p < 0.05. An increase for both, miR-126-3p and -5p levels (all p < 0.05, pre- vs. during and post-exercise was detected in the proHIIT group. Between group analysis revealed that miR-126-3p levels after LIT and proHIIT increased by 2.12 ± 2.55 and 1.24 ± 2.46 units (all p < 0.01, respectively, compared to HIIT (−1.05 ± 2.6 units.Conclusions: LIT and proHIIT may be performed to increase individual miR-126 levels. HIIT without progression was less effective in increasing miR-126.

  11. Aerobic Fitness for Young Athletes: Combining Game-based and High-intensity Interval Training.

    Science.gov (United States)

    Harrison, C B; Kinugasa, T; Gill, N; Kilding, A E

    2015-11-01

    This study compared the effect of game-based training (GT) vs. a mix of game-based training and high-intensity interval training (MT) on physical performance characteristics. 26 young athletes (13.9±0.3 years) were assigned to either GT (n=13) or MT (n=13) for 6 weeks. Game-based training consisted of 2×8-11 min 3 vs. 3 'bucketball' SSGs separated by 3 min of passive rest twice per week, while MT consisted of one SSGs session and one high-intensity session of 15 s runs at 90-95% of the speed reached at the end of the 30-15 intermittent fitness test (VIFT) interspersed with 15 s passive recovery. Peak oxygen uptake (V˙ O2peak), VIFT, jump height, and speed were assessed pre- and post-training. Following training, V˙ O2peak (5.5±3.3%; ES=large) improved after MT, whereas VIFT improved after MT (6.6±3.2%; ES, large) and GT (4.2±5.5%, ES=small). 5-m sprint improved after GT (ES=small), while 20 m sprint and jump height were unchanged. In conclusion, while MT and GT were both effective at increasing performance parameters, greater effects were seen following MT. Therefore, MT should be considered as the preferred training method for improving aerobic power in young athletes.

  12. Pacing, the missing piece of the puzzle to high-intensity interval training.

    Science.gov (United States)

    Zadow, E K; Gordon, N; Abbiss, C R; Peiffer, J J

    2015-03-01

    This study examined physiological and perceptual responses to matched work high-intensity interval training using all-out and 2 even-paced methodologies. 15 trained male cyclists performed 3 interval sessions of three 3-min efforts with 3 min of active recovery between efforts. The initial interval session was completed using all-out pacing, with the following 2 sessions being completed with computer- and athlete-controlled pacing in a randomised and semi-counterbalanced manner. Computer- and athlete-controlled intervals were completed at the mean power from the corresponding interval during the all-out trial. Oxygen consumption and ratings of perceived exertion were recorded during each effort. 20 min following each session, participants completed a 4-km time trial and provided sessional rating of perceived exertion. Oxygen consumption was greater during all-out (54.1±6.6 ml.kg(-1).min(-1); pintervals. Distribution of pace throughout high-intensity interval training can influence perceptual and metabolic stress along with subsequent performance and should be considered during the prescription of such training.

  13. High performance heat pump absorption cycles

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.; Longo, G.; Rossetto, L.

    1988-10-01

    Absorption heat pumps can provide high performances when operating in suitable cycles with multiple effects. This report describes some multistage cycles and evaluates the coefficient of performance realistically obtainable both in winter and summer working conditions.

  14. Moderate intensity, but not high intensity, treadmill exercise training alters power output properties in myocardium from aged rats.

    Science.gov (United States)

    Chung, Eunhee; Diffee, Gary M

    2012-11-01

    Aging is characterized by a progressive decline in cardiac function, but endurance exercise training has been shown to retard a number of deleterious effects of aging. However, underlying mechanisms by which exercise training improves age-related decrements in myocardial contractile function are not well understood. The purpose of this study was to determine the effects of exercise training on power output properties in permeablized (skinned) myocytes of old rats. Thirty-month-old rats were divided into sedentary control (C) and groups undergoing 11 weeks of treadmill exercise training at moderate intensity (MI) and at high intensity (HI). Peak power output normalized to maximal force was significantly increased in MI but not in HI compared to C with significant increases in atrial myosin light chain 1 in ventricle. These results suggest that MI exercise training is beneficial as a significant increase was seen in the ability of the myocardium to do work, but this effect was not seen with HI training.

  15. Metabolic responses to high protein diet in Korean elite bodybuilders with high-intensity resistance exercise

    Directory of Open Access Journals (Sweden)

    Choue Ryowon

    2011-07-01

    Full Text Available Abstract Background High protein diet has been known to cause metabolic acidosis, which is manifested by increased urinary excretion of nitrogen and calcium. Bodybuilders habitually consumed excessive dietary protein over the amounts recommended for them to promote muscle mass accretion. This study investigated the metabolic response to high protein consumption in the elite bodybuilders. Methods Eight elite Korean bodybuilders within the age from 18 to 25, mean age 21.5 ± 2.6. For data collection, anthropometry, blood and urinary analysis, and dietary assessment were conducted. Results They consumed large amounts of protein (4.3 ± 1.2 g/kg BW/day and calories (5,621.7 ± 1,354.7 kcal/day, as well as more than the recommended amounts of vitamins and minerals, including potassium and calcium. Serum creatinine (1.3 ± 0.1 mg/dl and potassium (5.9 ± 0.8 mmol/L, and urinary urea nitrogen (24.7 ± 9.5 mg/dl and creatinine (2.3 ± 0.7 mg/dl were observed to be higher than the normal reference ranges. Urinary calcium (0.3 ± 0.1 mg/dl, and phosphorus (1.3 ± 0.4 mg/dl were on the border of upper limit of the reference range and the urine pH was in normal range. Conclusions Increased urinary excretion of urea nitrogen and creatinine might be due to the high rates of protein metabolism that follow high protein intake and muscle turnover. The obvious evidence of metabolic acidosis in response to high protein diet in the subjects with high potassium intake and intensive resistance exercise were not shown in this study results. However, this study implied that resistance exercise with adequate mineral supplementation, such as potassium and calcium, could reduce or offset the negative effects of protein-generated metabolic changes. This study provides preliminary information of metabolic response to high protein intake in bodybuilders who engaged in high-intensity resistance exercise. Further studies will be needed to determine the effects of the intensity

  16. Low- Versus High-Intensity Plyometric Exercise During Rehabilitation After Anterior Cruciate Ligament Reconstruction.

    Science.gov (United States)

    Chmielewski, Terese L; George, Steven Z; Tillman, Susan M; Moser, Michael W; Lentz, Trevor A; Indelicato, Peter A; Trumble, Troy N; Shuster, Jonathan J; Cicuttini, Flavia M; Leeuwenburgh, Christiaan

    2016-03-01

    Plyometric exercise is used during rehabilitation after anterior cruciate ligament (ACL) reconstruction to facilitate the return to sports participation. However, clinical outcomes have not been examined, and high loads on the lower extremity could be detrimental to knee articular cartilage. To compare the immediate effect of low- and high-intensity plyometric exercise during rehabilitation after ACL reconstruction on knee function, articular cartilage metabolism, and other clinically relevant measures. Randomized controlled trial; Level of evidence, 2. Twenty-four patients who underwent unilateral ACL reconstruction (mean, 14.3 weeks after surgery; range, 12.1-17.7 weeks) were assigned to 8 weeks (16 visits) of low- or high-intensity plyometric exercise consisting of running, jumping, and agility activities. Groups were distinguished by the expected magnitude of vertical ground-reaction forces. Testing was conducted before and after the intervention. Primary outcomes were self-reported knee function (International Knee Documentation Committee [IKDC] subjective knee form) and a biomarker of articular cartilage degradation (urine concentrations of crosslinked C-telopeptide fragments of type II collagen [uCTX-II]). Secondary outcomes included additional biomarkers of articular cartilage metabolism (urinary concentrations of the neoepitope of type II collagen cleavage at the C-terminal three-quarter-length fragment [uC2C], serum concentrations of the C-terminal propeptide of newly formed type II collagen [sCPII]) and inflammation (tumor necrosis factor-α), functional performance (maximal vertical jump and single-legged hop), knee impairments (anterior knee laxity, average knee pain intensity, normalized quadriceps strength, quadriceps symmetry index), and psychosocial status (kinesiophobia, knee activity self-efficacy, pain catastrophizing). The change in each measure was compared between groups. Values before and after the intervention were compared with the groups

  17. [Reflected high-intensity motion signals as markers of left ventricular diastolic dysfunction].

    Science.gov (United States)

    Makarenko, E S

    2013-01-01

    Reflected high-intensity signals of left ventricular motion can be used for assessment of diastolic function of left ventricle. There are many correlations between reflected high-intensity signals, transmitral flow, and tissue Doppler imaging parameters. Diagnostic criteria of LV diastolic dysfunction based on measurement of LV motion are suggested.

  18. Refinement of Eutectic Silicon Phase of Aluminum A356 Alloy Using High-Intensity Ultrasonic Vibration

    Energy Technology Data Exchange (ETDEWEB)

    Jian, Xiaogang [ORNL; Han, Qingyou [ORNL

    2006-01-01

    The eutectic silicon in A356 alloy can be refined and modified using either chemical, quench, or superheating modification. We observed, for the first time, that the eutectic silicon can also be significantly refined using high-intensity ultrasonic vibration. Rosette-like eutectic silicon is formed during solidification of specimen treated with high-intensity ultrasonic vibration.

  19. The study towards high intensity high charge state laser ion sources.

    Science.gov (United States)

    Zhao, H Y; Jin, Q Y; Sha, S; Zhang, J J; Li, Z M; Liu, W; Sun, L T; Zhang, X Z; Zhao, H W

    2014-02-01

    As one of the candidate ion sources for a planned project, the High Intensity heavy-ion Accelerator Facility, a laser ion source has been being intensively studied at the Institute of Modern Physics in the past two years. The charge state distributions of ions produced by irradiating a pulsed 3 J/8 ns Nd:YAG laser on solid targets of a wide range of elements (C, Al, Ti, Ni, Ag, Ta, and Pb) were measured with an electrostatic ion analyzer spectrometer, which indicates that highly charged ions could be generated from low-to-medium mass elements with the present laser system, while the charge state distributions for high mass elements were relatively low. The shot-to-shot stability of ion pulses was monitored with a Faraday cup for carbon target. The fluctuations within ±2.5% for the peak current and total charge and ±6% for pulse duration were demonstrated with the present setup of the laser ion source, the suppression of which is still possible.

  20. The study towards high intensity high charge state laser ion sources

    Science.gov (United States)

    Zhao, H. Y.; Jin, Q. Y.; Sha, S.; Zhang, J. J.; Li, Z. M.; Liu, W.; Sun, L. T.; Zhang, X. Z.; Zhao, H. W.

    2014-02-01

    As one of the candidate ion sources for a planned project, the High Intensity heavy-ion Accelerator Facility, a laser ion source has been being intensively studied at the Institute of Modern Physics in the past two years. The charge state distributions of ions produced by irradiating a pulsed 3 J/8 ns Nd:YAG laser on solid targets of a wide range of elements (C, Al, Ti, Ni, Ag, Ta, and Pb) were measured with an electrostatic ion analyzer spectrometer, which indicates that highly charged ions could be generated from low-to-medium mass elements with the present laser system, while the charge state distributions for high mass elements were relatively low. The shot-to-shot stability of ion pulses was monitored with a Faraday cup for carbon target. The fluctuations within ±2.5% for the peak current and total charge and ±6% for pulse duration were demonstrated with the present setup of the laser ion source, the suppression of which is still possible.

  1. Liquid argon calorimeter performance at high rates

    CERN Document Server

    Seifert, F; The ATLAS collaboration

    2012-01-01

    The expected increase of luminosity at HL-LHC by a factor of ten with respect to LHC luminosities has serious consequences for the signal reconstruction, radiation hardness requirements and operations of the ATLAS liquid argon calorimeters in the endcap, respectively forward region. Small modules of each type of calorimeter have been built and exposed to a high intensity proton beam of 50 GeV at IHEP/Protvino. The beam is extracted via the bent crystal technique, offering the unique opportunity to cover intensities ranging from $10^6$ p/s up to $10^{12}$ p/s. This exceeds the deposited energy per time expected at HL-LHC by more than a factor of 100. The correlation between beam intensity and the read-out signal has been studied. The data show clear indications of pulse shape distortion due to the high ionization build-up, in agreement with MC expectations. This is also confirmed from the dependence of the HV currents on beam intensity.

  2. Liquid Argon Calorimeter performance at High Rates

    CERN Document Server

    Seifert, F; The ATLAS collaboration

    2013-01-01

    The expected increase of luminosity at HL-LHC by a factor of ten with respect to LHC luminosities has serious consequences for the signal reconstruction, radiation hardness requirements and operations of the ATLAS liquid argon calorimeters in the endcap, respectively forward region. Small modules of each type of calorimeter have been built and exposed to a high intensity proton beam of 50 GeV at IHEP/Protvino. The beam is extracted via the bent crystal technique, offering the unique opportunity to cover intensities ranging from $10^6$ p/s up to $3\\cdot10^{11}$ p/s. This exceeds the deposited energy per time expected at HL-LHC by more than a factor of 100. The correlation between beam intensity and the read-out signal has been studied. The data show clear indications of pulse shape distortion due to the high ionization build-up, in agreement with MC expectations. This is also confirmed from the dependence of the HV currents on beam intensity.

  3. Understanding the Impact of User Frustration Intensities on Task Performance Using the OCC Theory of Emotions

    Science.gov (United States)

    Washington, Gloria

    2012-01-01

    Have you heard the saying "frustration is written all over your falce"? Well this saying is true, but that is not the only place. Frustration is written all over your face and your body. The human body has various means to communicate an emotion without the utterance of a single word. The Media Equation says that people interact with computers as if they are human: this includes experiencing frustration. This research measures frustration by monitoring human body-based measures such as heart rate, posture, skin temperature. and respiration. The OCC Theory of Emotions is used to separate frustration into different levels or intensities. The results of this study showed that individual intensities of frustration exist, so that task performance is not degraded. Results from this study can be used by usability testers to model how much frustration is needed before task performance measures start to decrease.

  4. Attaining High Performance Communications A Vertical Approach

    CERN Document Server

    Gavrilovska, Ada

    2009-01-01

    Technological Advances and Problems of High Performance Communications. An ecosystem of solutions along a stack of technology layers. Cohesively collecting state-of-the-art contributions from leading researchers in industry, national laboratories, and academia, Attaining High Performance Communications: A Vertical Approach discusses various issues pertaining to high performance communications in a particular layer of a vertical stack. It explores efficient interconnection hardware, the architectural aspects of network adapters and their integration with processor cores, the design of scalable

  5. High Performance Spaceflight Computing (HPSC) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In 2012, the NASA Game Changing Development Program (GCDP), residing in the NASA Space Technology Mission Directorate (STMD), commissioned a High Performance...

  6. High performance carbon nanocomposites for ultracapacitors

    Science.gov (United States)

    Lu, Wen

    2012-10-02

    The present invention relates to composite electrodes for electrochemical devices, particularly to carbon nanotube composite electrodes for high performance electrochemical devices, such as ultracapacitors.

  7. Effect of high-intensity training on exercise-induced gene expression specific to ion homeostasis and metabolism

    DEFF Research Database (Denmark)

    Nordsborg, Nikolai; Bangsbo, Jens; Pilegaard, Henriette

    2003-01-01

    Changes in gene expression during recovery from high-intensity, intermittent, one-legged exercise were studied before and after 5.5 wk of training. Genes related to metabolism, as well as Na+, K+, and pH homeostasis, were selected for analyses. After the same work was performed before and after...

  8. The effect of playing formation on high-intensity running and technical profiles in English FA Premier League soccer matches

    DEFF Research Database (Denmark)

    Bradley, Paul S; Carling, Chris; Archer, Dave

    2011-01-01

    The aim of this study was to examine the effect of playing formation on high-intensity running and technical performance during elite soccer matches. Twenty English FA Premier League games were analysed using a multiple-camera computerized tracking system (n = 153 players). Overall ball possessio...

  9. MRI methods for the evaluation of high intensity focused ultrasound tumor treatment : Current status and future needs

    NARCIS (Netherlands)

    Hectors, Stefanie J C G; Jacobs, Igor; Moonen, Chrit T W; Strijkers, Gustav J; Nicolay, Klaas

    2016-01-01

    Thermal ablation with high intensity focused ultrasound (HIFU) is an emerging noninvasive technique for the treatment of solid tumors. HIFU treatment of malignant tumors requires accurate treatment planning, monitoring and evaluation, which can be facilitated by performing the procedure in an MR-gui

  10. Fatigue during high-intensity intermittent exercise: application to bodybuilding.

    Science.gov (United States)

    Lambert, Charles P; Flynn, Michael G

    2002-01-01

    Resistance exercise is an activity performed by individuals interested in competition, those who wish to improve muscle mass and strength for other sports, and for individuals interested in improving their strength and physical appearance. In this review we present information suggesting that phosphocreatine depletion, intramuscular acidosis and carbohydrate depletion are all potential causes of the fatigue during resistance exercise. In addition, recommendations are provided for nutritional interventions, which might delay muscle fatigue during this type of activity.

  11. High intensity physical exercise and pain in the neck and upper limb among slaughterhouse workers

    DEFF Research Database (Denmark)

    Sundstrup, Emil; Jakobsen, Markus D.; Andersen, Kenneth Jay

    2014-01-01

    about the effect among workers with repetitive and forceful work demands. Before performing randomized controlled trials it may be beneficial to assess the cross-sectional connection between exercise and musculoskeletal pain. We investigated the association between high intensity physical exercise...... and pain among 595 slaughterhouse workers in Denmark, Europe. Using logistic regression analyses, odds ratios for pain and work disability as a function of physical exercise, gender, age, BMI, smoking, and job position were estimated. The prevalence of pain in the neck, shoulder, elbow, and hand....../wrist was 48%, 60%, 40%, and 52%, respectively. The odds for experiencing neck pain were significantly lower among slaughterhouse workers performing physical exercise (OR = 0.70, CI: 0.49-0.997), whereas the odds for pain in the shoulders, elbow, or hand/wrist were not associated with exercise. The present...

  12. Moderate-to-High Intensity Physical Exercise in Patients with Alzheimer's Disease: A Randomized Controlled Trial

    DEFF Research Database (Denmark)

    Hoffmann, Kristine; Sobol, Nanna A; Frederiksen, Kristian S

    2016-01-01

    Background: Studies of physical exercise in patients with Alzheimer’s disease (AD) are few and results have been inconsistent. Objective: To assess the effects of a moderate-to-high intensity aerobic exercise program in patients with mild AD. Methods: In a randomized controlled trial, we recruited...... 200 patients with mild AD to a supervised exercise group (60-min sessions three times a week for 16 weeks) or to a control group. Primary outcome was changed from baseline in cognitive performance estimated by Symbol Digit Modalities Test (SDMT) in the intention-to-treat (ITT) group. Secondary...... outcomes included changes in quality of life, ability to perform activities of daily living, and in neuropsychiatric and depressive symptoms. Results: The ITT analysis showed no significant differences between intervention and control groups in change from baseline of SDMT, other cognitive tests, quality...

  13. Calculation of acceptance of high intensity superconducting proton linac for Project X

    CERN Document Server

    Saini, A; Solyak, N; Mishra, S; Yakovlev, V

    2011-01-01

    Project-X is the proposed high intensity proton facility to be built at Fermilab, US. Its Superconducting Linac, to be used at first stage of acceleration, will be operated in continuous wave (CW) mode. The Linac is divided into three sections on the basis of operating frequencies & six sections on the basis of family of RF cavities to be used for the acceleration of beam from 2.5 MeV to 3 GeV. The transition from one section to another can limit the acceptance of the Linac if these are not matched properly. We performed a study to calculate the acceptance of the Linac in both longitudinal and transverse plane. Investigation of most sensitive area which limits longitudinal acceptance and study of influence of failure of beam line elements at critical position, on acceptance are also performed.

  14. A radiation emission shielding method for high intensity focus ultrasound probes.

    Science.gov (United States)

    Wu, Hao; Shen, Guofeng; Chen, Yazhu

    2015-01-01

    Electromagnetic compatibility (EMC) is a key issue in the design and development of safe and effective medical instruments. The treatment probes of high intensity focused ultrasound (HIFU) systems not only receive and transmit electromagnetic waves, but also radiate ultrasound waves, resulting in electromagnetic coupling. In this paper, an electromagnetic shielding method involving the enclosure of the probe in a copper wire mesh was introduced. First, sound pressure distribution simulations and measurements were performed using a hydrophone in order to evaluate the effects of the wire mesh on the acoustic performance of the HIFU system. The results indicated that the wire mesh did not disturb the normalized sound pressure field. In addition, the attenuation of the maximum pressure in the focal plane was equal to 6.2%. Then, the electronic emission level was tested in a chamber. After the implementation of the wire mesh, the 10-100 MHz frequency band radiation was suppressed, and the HIFU system satisfied the national EMC standards.

  15. Tools for simulation of high beam intensity ion accelerators; Simulationswerkzeuge fuer die Berechnung hochintensiver Ionenbeschleuniger

    Energy Technology Data Exchange (ETDEWEB)

    Tiede, Rudolf

    2009-07-09

    A new particle-in-cell space charge routine based on a fast Fourier transform was developed and implemented to the LORASR code. It provides the ability to perform up to several 100 batch run simulations with up to 1 million macroparticles each within reasonable computation time. The new space charge routine was successfully validated in the framework of the European ''High Intensity Pulsed Proton Injectors'' (HIPPI) collaboration: Several static Poisson solver benchmarking comparisons were performed, as well as particle tracking comparisons along the GSI UNILAC Alvarez section. Moreover machine error setting routines and data analysis tools were developed and applied on error studies for the ''Heidelberg Cacer Therapy'' (HICAT) IH-type drift tube linear accelerator (linac), the FAIR Facility Proton Linac and the proposal of a linac for the ''International Fusion Materials Irradiation Facility'' (IFMIF) based on superconducting CH-type structures. (orig.)

  16. High Performance Work Systems, Performance and Innovativeness in Small Firms

    OpenAIRE

    Jan Kok; Deanne den Hartog

    2006-01-01

    The research presented in this paper focuses on the effectiveness of a high performance work system. This system is comprised of practices in the areas of extensiveness of staffing, performance based pay, pay level, job rotation, training and participation. In particular, this study focuses on the effects of such a system on the performance of small and medium-sized enterprises. Results of our study, among small and medium size enterprises in the Netherlands, show that firms with such a syste...

  17. The effect of high and low exercise intensity periods on a simple memory recognition test

    Directory of Open Access Journals (Sweden)

    Ben Rattray

    2016-09-01

    Conclusion: Changes in cognitive performance with variations in exercise intensity are likely to have implications for sport and occupational settings. The timing of cognitive tests to exercise intensity changes as well as use of short cognitive assessments will be important for future work.

  18. Extremely short duration high intensity interval training substantially improves insulin action in young healthy males

    DEFF Research Database (Denmark)

    Babraj, John A; Vollaard, Niels B J; Keast, Cameron

    2009-01-01

    BACKGROUND: Traditional high volume aerobic exercise training reduces cardiovascular and metabolic disease risk but involves a substantial time commitment. Extremely low volume high-intensity interval training (HIT) has recently been demonstrated to produce improvements to aerobic function, but i...

  19. Heart rate variability during high-intensity field exercise in female distance runners.

    Science.gov (United States)

    Sumi, K; Suzuki, S; Matsubara, M; Ando, Y; Kobayashi, F

    2006-10-01

    The purposes of this study were to demonstrate the transition of heart rate variability (HRV) during trials in the field and to examine the relationship between peak frequency of high-frequency band (HF) and stride frequency. Ten healthy long-distance college female runners (age 19-21 years) performed a 3000 m realistic time trial. The time-series power spectrum analysis by maximum entropy method was used to evaluate cardiac autonomic nervous activity during the race. Cross-correlation coefficients were calculated to estimate the degree of linear co-ordination between the central peak frequency of HF and stride frequency. Just after starting, the decrease in HF (0.15-1.00 Hz) and a transient increase of low-frequency band (LF)/HF were found. After that, the HF remained at a low level and LF/HF decreased sharply. These findings suggested that the parasympathetic activity was suppressed and sympathetic activity increased just after starting, and the sympathetic activity reached the saturated level according to continuation of high-intensity exercise. In spite of the significant decrease of HRV during trials, peak frequency of HF could be differentiated clearly. The cross-correlation coefficient of peak frequency of HF and stride frequency was from 0.703 to 0.868. This finding indicated that exercise rhythm reflected HRV during high-intensity running in the field.

  20. High intensity electromagnetic field gerenation using a transportable reverberation chamber

    NARCIS (Netherlands)

    Leferink, Frank

    2008-01-01

    A reverberation chamber can create very high field strength with moderate input power. Existing chambers are making use of a paddle wheel to change the resonant modes in the chamber. A transportable reverberation chamber with vibrating walls will be presented. Inside this Vibrating Intrinsic Reverbe