WorldWideScience

Sample records for high intensity 48ca

  1. Ca-48 handling for a cyclotron ECR ion source to produce highly intense ion beams

    International Nuclear Information System (INIS)

    Lebedev, V.Ya.; Bogomolov, S.L.; Dmitriev, S.N.; Kutner, V.B.; Shamanin, A.N.; Yakushev, A.B.

    2002-01-01

    Production of highly intense ion beams of 48 Ca is one of the main tasks in experiments carried out within the framework of the synthesis of new superheavy elements. 48 Ca is very rare and expensive isotope, therefore there is necessity to reach the high intensity of ion beams of the isotope at a low consumption rate. Analysis and our preliminary experiments have showed that the best way of producing highly intense calcium ion beams is evaporation of metallic calcium in an ECR ion source. So we have developed a technique of metallic 48 Ca production by reducing CaO (this chemical form is available at the market with 40-80% of 48 Ca ) with aluminium powder. We used two tantalum crucibles: a larger, with a mixture of CaO + Al heated up to 1250 deg C, which was connected to the smaller (2 mm I.D. and 30 mm long) in which calcium vapour condensed. The temperature distribution in the small crucible was about 50 deg C at the bottom and about 500 deg C in the middle of the crucible. The pressure inside of the set-up was between 0.1 and 1 Pa. The production rate of metallic 48 Ca was 10-20 mg/h. The crucible with the condensed metallic Ca in argon atmosphere was transferred to the ECR-4M ion source, where it was inserted in a wired tubular oven and the calcium evaporation was controlled through the oven power supply. The application of metallic 48 Ca as the working substance for the ECR-4M ion source of the U-400 cyclotron of allowed us to approach a stable high intensity of 48 Ca ion beams: the intensities for the internal and external beams were 10 13 c -1 and 3.10 12 c -1 , respectively, at a consumption rate about 0.4 mg/h. A technique was developed for the reclamation of 48 Ca from the residue inside of the large crucible and from the inner parts of the ECR ion source. Extracting Ca from the inner parts of the ion source enabled us to save up to some 25% of the calcium used in the ECR ion source, so that the actual consumption rate was about 0.3 mg/h at the highest 48

  2. Ca-48 targets - Home and abroad!

    Science.gov (United States)

    Greene, John P.; Carpenter, Michael; Janssens, Robert V. F.

    2018-05-01

    Using the method of reduction/distillation, high-purity films of robust and ductile calcium metal were prepared for use as targets in nuclear physics experiments. These targets, however, are extremely air-sensitive and procedures must be developed for their handling and use without exposure to the air. In most instances, the thin 48Ca target is used on a carrier foil (backing) and a thin covering film of similar material is employed to further reduce re-oxidation. Un-backed metallic targets are rarely produced due to these concerns. In addition, the low natural abundance of the isotope 48Ca provided an increased incentive for the best efficiencies available in their preparation. Here, we describe the preparation of 48Ca targets employing a gold backing and thin gold cover for use at home, Argonne National Laboratory (ANL), as well as abroad, at Osaka University. For the overseas shipments, much care and preparation were necessary to ensure good targets and safe arrival to the experimental facilities.

  3. High intensity metallic ion beams from an ecr ion source at GANIL

    International Nuclear Information System (INIS)

    Leherissier, P.; Barue, C.; Canet, C.; Dupuis, M.; Flambard, J.L.; Gaubert, G.; Gibouin, S.; Huguet, Y.; Jardin, P.; Lecesne, N.; Lemagnen, F.; Leroy, R.; Pacquet, J.Y.; Pellemoine-Landre, F.; Rataud, J.P.; Jaffres, P.A.

    2001-01-01

    In the recent years, progress concerning the production of high intensity of metallic ions beams ( 58 Ni, 48 Ca, 76 Ge) at Ganil have been performed. The MIV0C method has been successfully used to produce a high intensity nickel beam with the ECR4 ion source: 20 eμA of 58 Ni 11+ at 24 kV extraction voltage. This beam has been maintained for 8 days and accelerated up to 74.5 MeV/u by our cyclotrons with a mean intensity of 0.13 pμA on target. This high intensity, required for experiment, led to the discovery of the doubly magic 48 Ni isotope. The oven method has been first tested with natural metallic calcium on the ECR4 ion source, then used to produce a high power beam (740 W on target i.e. 0.13 pμA accelerated up to 60 MeV/u) of 48 Ca still keeping a low consumption (0.09 mg/h). A germanium beam is now under development, using the oven method with germanium oxide. The ionization efficiencies have been measured and compared. (authors)

  4. Dipole and electric quadrupole excitations in 40,48Ca

    International Nuclear Information System (INIS)

    Hartmann, T.; Enders, J.; Mohr, P.; Vogt, K.; Volz, S.; Zilges, A.

    2001-11-01

    Photon scattering experiments have been performed to investigate the structure of the two doubly magic nuclei 40,48 Ca. The method is highly selective to induce low-order multipole transitions i.e., E1, M1, and E2 from the ground state. We determined the energies and spins of excited states and the absolute strengths of the γ-decays in a model independent way. We find the summed electric dipole strengths below 10 MeV to exhaust the energy weighted sum rule (EWSR) by 0.023% and 0.27%, respectively. The summed electric quadrupole strengths are Σ B(E2) ↑ = 332 e 2 fm 4 and 407 e 2 fm 4 for 40 Ca and 48 Ca, respectively. In order to explain the difference in the E1 strengths of the two isotopes several theoretical models are discussed. (orig.)

  5. Spin decomposition of the responses of 44Ca and 48Ca to 300 MeV protons

    International Nuclear Information System (INIS)

    Baker, F.T.; Bimbot, L.; Fergerson, R.W.; Glashausser, C.; Green, A.; Haeusser, O.; Hicks, K.; Jones, K.; Miller, C.A.; Vetterli, M.; Abegg, R.; Beatty, D.; Bonin, B.; Castel, B.; Chen, X.Y.; Cupps, V.; Djalali, C.; Henderson, R.; Jackson, K.P.; Jeppesen, R.; Nakayama, K.; Nanda, S.K.; Sawafta, R.; Yen, S.; Institut de Physique Nucleaire, F-91406 Orsay, France; Rutgers University, Piscataway, New Jersey 08854; Simon Fraser University, Burnaby, Canada V5A1S6; TRIUMF, 4004 Westbrook Mall, Vancouver, Canada V6T2A3; Los Alamos National Laboratory, Los Alamos, New Mexico 87544; Centre d'Etudes Nucleaires de Saclay, 91191 Gif sur Yvette, CEDEX, France; Queen's University, Kingston, Canada K7L3N6; University of Colorado, Boulder, Colorado 80309; University of South Carolina, Columbia, South Carolina 29208; Continuous Electron Beam Accelerator Facility, 12000 Jefferson Ave., Newport News, Virginia 23606; University of Alberta, Edmonton, Canada T6G2J1)

    1991-01-01

    Angular distributions of the double-differential cross section d 2 σ/dΩ dE(σ) and the spin-flip probability S nn have been measured for inclusive proton inelastic scattering from 44 Ca at 290 MeV and from 48 Ca at 318 MeV. Excitation energies up to about 50 MeV for 44 Ca and 40 MeV for 48 Ca have been investigated over the laboratory angular ranges of 3 degree to 12 degree for 44 Ca and 3 degree to 9 degree for 48 Ca. Multipole decompositions of angular distributions of both the spin-flip cross section σS nn and the estimated cross section for ΔS=0 transitions have been performed. Distributions of strengths were deduced for ΔL=1, ΔS=0 (the giant dipole), ΔL=2, ΔS=0 (the giant quadrupole), ΔL=0, ΔS=1 (the magnetic dipole), ΔL=1, ΔS=1 (the spin dipole), and ΔL=2, ΔS=1 (the spin quadrupole). The ΔS=0 summed strengths for 44 Ca are lower than for 40 Ca and 48 Ca. The spin-dipole summed strengths are found to be approximately independent of A. For 48 Ca, essentially all M1 strength observed was in the 10.23 MeV 1 + state; for 44 Ca, M1 strength was observed to be fragmented over a range of 7 to 18 Mev

  6. Isospin excitation of nucleus in 42,44,48Ca (p,n)42,44,48Sc

    International Nuclear Information System (INIS)

    Suzuki, Keiji

    2002-01-01

    To obtain information of (p,n) reaction of heavy nucleus in 100 MeV or less, 42,44,48 Ca(p,n) 42,44,48 Sc was observed on the Cyclotron Radio Isotope Center in Tohoku University. The experimental results showed that 7, 8 and 10 spin parities were determined for 42 Sc, 44 Sc and 48 SC, respectively. It was the first determination of one and two negative parity transition of 42 Sc and 48 Sc,respectively, by (p,n) reaction. The full space wave function made by 0f1p shell effective interaction by Richter,et al is good accuracy and reliability. On the (p,n) reaction at E p =35 MeV, the transition matrix elements of 42 Ca, 44 Ca and 48 Ca were derived. On the experiment of 42 Ca(p,n) 42 Sc at E p 2 on energy was agreed with the calculation results by Franey and Love. The nuclear structure of 42 Ca was thought to show more stronger U(4) symmetry, because strong GT transition at T=1 was not observed, which was expected by j-j bonding shell model calculation. (S.Y.)

  7. Electric Dipole Polarizability of ^{48}Ca and Implications for the Neutron Skin.

    Science.gov (United States)

    Birkhan, J; Miorelli, M; Bacca, S; Bassauer, S; Bertulani, C A; Hagen, G; Matsubara, H; von Neumann-Cosel, P; Papenbrock, T; Pietralla, N; Ponomarev, V Yu; Richter, A; Schwenk, A; Tamii, A

    2017-06-23

    The electric dipole strength distribution in ^{48}Ca between 5 and 25 MeV has been determined at RCNP, Osaka from proton inelastic scattering experiments at forward angles. Combined with photoabsorption data at higher excitation energy, this enables the first extraction of the electric dipole polarizability α_{D}(^{48}Ca)=2.07(22)  fm^{3}. Remarkably, the dipole response of ^{48}Ca is found to be very similar to that of ^{40}Ca, consistent with a small neutron skin in ^{48}Ca. The experimental results are in good agreement with ab initio calculations based on chiral effective field theory interactions and with state-of-the-art density-functional calculations, implying a neutron skin in ^{48}Ca of 0.14-0.20 fm.

  8. Inhibition of long-term potentiation in the schaffer-CA1 pathway by repetitive high-intensity sound stimulation.

    Science.gov (United States)

    Cunha, A O S; de Oliveira, J A C; Almeida, S S; Garcia-Cairasco, N; Leão, R M

    2015-12-03

    High-intensity sound can induce seizures in susceptible animals. After repeated acoustic stimuli changes in behavioural seizure repertoire and epileptic EEG activity might be seen in recruited limbic and forebrain structures, a phenomenon known as audiogenic kindling. It is postulated that audiogenic kindling can produce synaptic plasticity events leading to the spread of epileptogenic activity to the limbic system. In order to test this hypothesis, we investigated if long-term potentiation (LTP) of hippocampal Schaffer-CA1 synapses and spatial navigation memory are altered by a repeated high-intensity sound stimulation (HISS) protocol, consisting of one-minute 120 dB broadband noise applied twice a day for 10 days, in normal Wistar rats and in audiogenic seizure-prone rats (Wistar Audiogenic Rats - WARs). After HISS all WARs exhibited midbrain seizures and 50% of these animals developed limbic recruitment, while only 26% of Wistar rats presented midbrain seizures and none of them had limbic recruitment. In naïve animals, LTP in hippocampal CA1 neurons was induced by 50- or 100-Hz high-frequency stimulation of Schaffer fibres in slices from both Wistar and WAR animals similarly. Surprisingly, HISS suppressed LTP in CA1 neurons in slices from Wistar rats that did not present any seizure, and inhibited LTP in slices from Wistar rats with only midbrain seizures. However HISS had no effect on LTP in CA1 neurons from slices of WARs. Interestingly HISS did not alter spatial navigation and memory in both strains. These findings show that repeated high-intensity sound stimulation prevent LTP of Schaffer-CA1 synapses from Wistar rats, without affecting spatial memory. This effect was not seen in hippocampi from audiogenic seizure-prone WARs. In WARs the link between auditory stimulation and hippocampal LTP seems to be disrupted which could be relevant for the susceptibility to seizures in this strain. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.

  9. Capture reactions of 40Ca and 48Ca with targets of 197Au and 208Pb

    International Nuclear Information System (INIS)

    Stokstad, R.; Chan, Y.; Chavez, E.

    1988-03-01

    The reactions of 40 Ca and 48 Ca with targets of 197 Au and 208 Pb have been measured in the region from below the interaction barrier to about twice the barrier energy. The fission-like fragments were detected in a pair of position-sensitive, multi-wire proportional counters and were identified from measurements of position and time using two-body kinematics. In the region above the barrier the cross sections for capture are less than those given by the touching condition, indicating that an /open quotes/extra push/close quotes/ is required to induce capture. The observations for 40 Ca and 48 Ca show different fissilities for the onset of the extra push and indicate that charge equilibration may be an important factor governing capture reactions. Below the barrier the cross sections show an enhancement relative to the prediction for a one dimensional barrier. The enhancements are larger for 40 Ca than for 48 Ca (for both targets) and this is in qualitative agreement with predictions based on the coupling of the relative motion to low-lying collective states. Both above and below the barrier, we find that the change in the light partner, from 48 Ca to 40 Ca, has a larger effect on the cross sections than the change from 208 Pb to 197 Au, after correction for the change in the Coulomb barrier. 16 refs., 7 figs

  10. CORRELATION OF 48Ca, 50Ti, AND 138La HETEROGENEITY IN THE ALLENDE REFRACTORY INCLUSIONS

    International Nuclear Information System (INIS)

    Chen, Hsin-Wei; Lee, Typhoon; Lee, Der-Chuen; Chen, Jiang-Chang

    2015-01-01

    Precise determinations of 48 Ca anomalies in Allende calcium–aluminum-rich inclusions (CAIs) are reported in this work. There are endemic positive 48 Ca/ 44 Ca anomalies in all analyzed CAIs after normalization to 42 Ca/ 44 Ca, and it is clearly shown that there is no simple correlation between 48 Ca/ 44 Ca and 50 Ti/ 48 Ti anomalies, in agreement with Jungck et al. Compared to the 48 Ca/ 44 Ca versus 50 Ti/ 48 Ti correlation line defined by differentiated meteorites, reported by Chen et al., the CAIs plot to elevated 50 Ti/ 48 Ti. Assuming the 48 Ca/ 44 Ca anomalies of both CAIs and differentiated meteorites came from the same source, excess 50 Ti anomalies in CAIs can be calculated by subtracting the part associated with 48 Ca/ 44 Ca. These excesses show a linear correlation with 138 La anomalies, a neutrino-process nuclide. According to current stellar nucleosynthetic models, we therefore suggest that the solar system 48 Ca, 50 Ti, and 138 La isotopic variations are made of mixtures between grains condensed from ejecta of neutron-rich accretion-induced SNe Ia and the O/Ne–O/C zone of core-collapse SNe II

  11. Development of a high intensity sup 4 sup 8 Ca ion beam for the heavy element program

    CERN Document Server

    Wutte, D C; Lyneis, C

    2002-01-01

    A high intensity sup 4 sup 8 Ca ion beam has been developed at the 88 Inch Cyclotron for the synthesis of sup 2 sup 8 sup 3 112 using the reaction sup 2 sup 3 sup 8 U( sup 4 sup 8 Ca, 3n). An ion beam intensity of approx 700 pnA was delivered on target, resulting in a total dose of 2 x 10 sup 1 sup 8 ions over a six day period. Since sup 4 sup 8 Ca is a very expensive and rare isotope minimal consumption is essential. Therefore a new oven [1] and special tantalum liner [2] have been developed for the AECR-U ion source during the last year to improve the metal ion beam efficiency. Both the LBL ECR and the AECR-U ion sources are built with radial access. Six radial slots between the sextupole magnet bars provide additional pumping and easy access to the plasma chamber for ovens and feedthroughs. Two types of radial ovens have been used at LBNL in the past, operating at temperatures up to 2100 C.

  12. Determination of 40Ca and 48Ca matter densities by 600 MeV and 1 GeV proton elastic scattering

    International Nuclear Information System (INIS)

    Brissaud, I.; Campi, X.

    1979-02-01

    The 600MeV and 1GeV data of proton elastic scattering on 40 Ca and 48 Ca have been analyzed in the framework of the Glauber model. The matter distributions are extracted from the data in an approximately model-independent form based on a Fourier series expansion. A similar method is used to deduce directly the 48 Ca- 40 Ca neutron density difference

  13. Conserving RPA and the response of 48Ca

    International Nuclear Information System (INIS)

    Brand, M.G.E.; Allaart, K.; Dickhoff, W.H.

    1988-01-01

    The connection between the single-particle self-energy and the corresponding conserving particle-hole (ph) interaction, discussed long ago by Kadanoff and Baym, is employed to study the response of 48 Ca. Second order self-energy contributions are taken into account in the construction of the energy dependent ph interaction. From this perspective it is possible to make contact with other approaches which also aim to incorporate the coupling to 2p2h excitations within the RPA framework. The method is used to study both the discrete low-energy states as well as the giant resonances in both 48 Ca and 48 Sc using a realistic G matrix interaction based on meson exchange. The calculated strength distribution compares favorably with experimental but the strength below 15 MeV is still somewhat too large as compared to experiment for all types of excitations. The quenching of magnetic and Gamow-Teller strength due to 2p2h admixture amounts to about 30%. (orig.)

  14. Decay properties of exotic N ≅ 28 S and Cl nuclei and the 48Ca/46Ca abundance ratio

    International Nuclear Information System (INIS)

    Sorlin, O.; Guillemaud-Mueller, D.; Mueller, A.C.; Borrel, V.; Dogny, S.; Pougheon, F.; Anne, R.; Lewitowicz, M.; Saint-Laurent, M.G.; Borcea, C.; Fifield, L.K.; Bazin, D.; Thielemann, F.K.; Hillebrandt, W.

    1992-01-01

    Beta-decay half-lives and β-delayed neutron-emission probabilities of the very neutron-rich nuclei 44 S and 45-47 Cl have been measured. These isotopes, which lie at or close to the N=28 magic shell were produced in interactions of a 60 MeV/u 48 Ca beam from GANIL (Grand Accelerateur National d'Ions Lourds) with a 64 Ni target and were separated by the doubly achromatic spectrometer LISE (Ligne d'Ions Super Epluches). Their decay was studied by a β-n time correlation measurement. The results are compared to recent model predictions and indicate a rapid weakening of the N=28 shell effect below 48 20 Ca 28 . The nuclear structure effects reflected in the decay properties of the exotic S and Cl isotopes may be the clue for the astrophysical understanding of the unusual 48 Ca/ 46 Ca abundance ratio measured in the solar system as well as the Ca-Ti-Cr anomalies observed in EK-inclusions of the Allende meteorite

  15. Analysis of the 48Ca neutron skin using a nonlocal dispersive-optical-model self-energy

    Science.gov (United States)

    Atkinson, Mack; Mahzoon, Hossein; Dickhoff, Willem; Charity, Robert

    2017-09-01

    A nonlocal dispersive-optical-model (DOM) analysis of the 40Ca and 48Ca nuclei has been implemented. The real and imaginary potentials are constrained by fitting to elastic-scattering data, total and reaction cross sections, energy level information, particle number, and the charge densities of 40Ca and 48Ca, respectively. The nonlocality of these potentials permits a proper dispersive self-energy which accurately describes both positive and negative energy observables. 48Ca is of particular interest because it is doubly magic and has a neutron skin due to the excess of neutrons. The DOM neutron skin radius is found to be rskin = 0.245 , which is larger than most previous calculations. The neutron skin is closely related to the symmetry energy which is a crucial part of the nuclear equation of state. The combined analysis of 40Ca and 48Ca energy densities provides a description of the density dependence of the symmetry energy which is compared with the 48Ca neutron skin. Results for 208Pb will also become available in the near future. NSF.

  16. CORRELATION OF {sup 48}Ca, {sup 50}Ti, AND {sup 138}La HETEROGENEITY IN THE ALLENDE REFRACTORY INCLUSIONS

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Hsin-Wei; Lee, Typhoon; Lee, Der-Chuen; Chen, Jiang-Chang, E-mail: hart.chen@bristol.ac.uk [Institute of Earth Sciences, Academia Sinica, Taipei, Taiwan, ROC (China)

    2015-06-10

    Precise determinations of {sup 48}Ca anomalies in Allende calcium–aluminum-rich inclusions (CAIs) are reported in this work. There are endemic positive {sup 48}Ca/{sup 44}Ca anomalies in all analyzed CAIs after normalization to {sup 42}Ca/{sup 44}Ca, and it is clearly shown that there is no simple correlation between {sup 48}Ca/{sup 44}Ca and {sup 50}Ti/{sup 48}Ti anomalies, in agreement with Jungck et al. Compared to the {sup 48}Ca/{sup 44}Ca versus {sup 50}Ti/{sup 48}Ti correlation line defined by differentiated meteorites, reported by Chen et al., the CAIs plot to elevated {sup 50}Ti/{sup 48}Ti. Assuming the {sup 48}Ca/{sup 44}Ca anomalies of both CAIs and differentiated meteorites came from the same source, excess {sup 50}Ti anomalies in CAIs can be calculated by subtracting the part associated with {sup 48}Ca/{sup 44}Ca. These excesses show a linear correlation with {sup 138}La anomalies, a neutrino-process nuclide. According to current stellar nucleosynthetic models, we therefore suggest that the solar system {sup 48}Ca, {sup 50}Ti, and {sup 138}La isotopic variations are made of mixtures between grains condensed from ejecta of neutron-rich accretion-induced SNe Ia and the O/Ne–O/C zone of core-collapse SNe II.

  17. Spins, moments and charge radii beyond $^{48}$Ca

    CERN Multimedia

    Neyens, G; Rajabali, M M; Hammen, M; Blaum, K; Froemmgen, N E; Garcia ruiz, R F; Kreim, K D; Budincevic, I

    Laser spectroscopy of $^{49-54}$Ca is proposed as a continuation of the experimental theme initiated with IS484 “Ground-state properties of K-isotopes from laser and $\\beta$-NMR spectroscopy” and expanded in INTC-I-117 “Moments, Spins and Charge Radii Beyond $^{48}$Ca.” It is anticipated that the charge radii of these isotopes can show strong evidence for the existence of a sub-shell closure at N=32 and could provide a first tentative investigation into the existence of a shell effect at N=34. Furthermore the proposed experiments will simultaneously provide model-independent measurements of the spins, magnetic moments and quadrupole moments of $^{51,53}$Ca permitting existing and future excitation spectra to be pinned to firm unambiguous ground states.

  18. Search for weak M 1 transitions in 48Ca with inelastic proton scattering

    Science.gov (United States)

    Mathy, M.; Birkhan, J.; Matsubara, H.; von Neumann-Cosel, P.; Pietralla, N.; Ponomarev, V. Yu.; Richter, A.; Tamii, A.

    2017-05-01

    Background: The quenching of spin-isospin modes in nuclei is an important field of research in nuclear structure. It has an impact on astrophysical reaction rates and on fundamental processes like neutrinoless double-β decay. Gamow-Teller (GT) and spin-flip M 1 strengths are quenched. Concerning the latter, the Jπ=1+ resonance in the doubly magic nucleus 48Ca, dominated by a single transition, serves as a reference case. Purpose: The aim of the present work is to search for weak M 1 transitions in 48Ca with a high-resolution (p ,p') experiment at 295 MeV and forward angles including 0∘ and a comparison with results from a similar study using backward-angle electron scattering at low momentum transfers in order to estimate their contribution to the total B (M 1 ) strength in 48Ca. Methods: The spin-M 1 cross sections of individual peaks in the spectra are deduced with a multipole decomposition analysis (MDA) and converted to reduced spin-M 1 transition strengths by using the unit cross-section method. For a comparison with electron-scattering results, corresponding reduced B (M 1 ) transition strengths are extracted following the approach outlined in Birkhan et al. [Phys. Rev. C 93, 041302(R) (2016), 10.1103/PhysRevC.93.041302]. Results: In total, 30 peaks containing a M 1 contribution are found in the excitation energy region 7-13 MeV. The resulting B (M 1 ) strength distribution compares well to the electron-scattering results considering different factors limiting the sensitivity in both experiments and the enhanced importance of mechanisms breaking the proportionality of nuclear cross sections and electromagnetic matrix elements for weak transitions as studied here. The total strength of 1.14(7) μN2 deduced assuming a nonquenched isoscalar part of the (p ,p') cross sections agrees with the (e ,e') result of 1.21(13) μN2. A bin-wise analysis above 10 MeV provides an upper limit of 1.51(17) μN2. Conclusions: The present results confirm the previous electron

  19. Quasi-elastic transfer and charge-exchange reactions in collisions of 48Ti on 42Ca and 26Mg

    International Nuclear Information System (INIS)

    Brendel, C.

    1985-01-01

    At the GSI magnetic spectrometer quasi-elastic transfer and charge-exchange reactions of the system 48 Ti + 42 Ca at incident energies E lab = 240, 300, and 385 MeV and additionally at the higher projectile energy the system 48 Ti + 26 Mg were studied each in the excitation energy range up to E x ≅ 80 MeV. The transition strength was for each particle-hole configuration of the final system calculated by means of the DWBA and subsequently folded with a Breit-Wigner distribution. The localization of the strength of the cross section and the specific structure of the energy spectra were at incident energies between 6 and 8 MeV/amu for all angles well reproduced. By an extension of the core-excitation model to many-stage reactions the charge-exchange reaction 48 Ti + 42 Ca48 Sc + 42 Sc could be described as sequential two-stage process. In the two-neutron stripping reaction 48 Ti + 42 Ca → 46 Ti + 44 Ca a surprisingly narrow line with a width of the experimental resolution and an excitation energy of E x = 17.8 MeV was measured at angles smaller than the grazing angle. In the 48 Ti + 26 Mg system the corresponding 46 Ti spectra show also under forward angles structures at excitation energies between 8 and 16 MeV. These lines can be explained as two-neutron states with high spin. (orig./HSI) [de

  20. Cold fusion reactions with 48Ca

    International Nuclear Information System (INIS)

    Gaeggeler, H.W.; Jost, D.T.; Tuerler, A.

    1989-04-01

    Cold fusion reactions with 48 Ca on the targets 208 Pb, 209 Bi, 197 Au, 184 W, 180 Hf are reported. The experiments were performed at the velocity filter SHIP of GSI. The maximum cross sections show a steep descent by about four orders of magnitude when going from 224 Th to 228 U as compound nuclei. Between uranium and einsteinium the cross sections stay rather low and increase by about two orders of magnitude for nobelium. For lawrencium the cross section decrease again. 7 figs., 1 tab., 38 refs

  1. Ryanodine receptor fragmentation and sarcoplasmic reticulum Ca2+ leak after one session of high-intensity interval exercise.

    Science.gov (United States)

    Place, Nicolas; Ivarsson, Niklas; Venckunas, Tomas; Neyroud, Daria; Brazaitis, Marius; Cheng, Arthur J; Ochala, Julien; Kamandulis, Sigitas; Girard, Sebastien; Volungevičius, Gintautas; Paužas, Henrikas; Mekideche, Abdelhafid; Kayser, Bengt; Martinez-Redondo, Vicente; Ruas, Jorge L; Bruton, Joseph; Truffert, Andre; Lanner, Johanna T; Skurvydas, Albertas; Westerblad, Håkan

    2015-12-15

    High-intensity interval training (HIIT) is a time-efficient way of improving physical performance in healthy subjects and in patients with common chronic diseases, but less so in elite endurance athletes. The mechanisms underlying the effectiveness of HIIT are uncertain. Here, recreationally active human subjects performed highly demanding HIIT consisting of 30-s bouts of all-out cycling with 4-min rest in between bouts (≤3 min total exercise time). Skeletal muscle biopsies taken 24 h after the HIIT exercise showed an extensive fragmentation of the sarcoplasmic reticulum (SR) Ca(2+) release channel, the ryanodine receptor type 1 (RyR1). The HIIT exercise also caused a prolonged force depression and triggered major changes in the expression of genes related to endurance exercise. Subsequent experiments on elite endurance athletes performing the same HIIT exercise showed no RyR1 fragmentation or prolonged changes in the expression of endurance-related genes. Finally, mechanistic experiments performed on isolated mouse muscles exposed to HIIT-mimicking stimulation showed reactive oxygen/nitrogen species (ROS)-dependent RyR1 fragmentation, calpain activation, increased SR Ca(2+) leak at rest, and depressed force production due to impaired SR Ca(2+) release upon stimulation. In conclusion, HIIT exercise induces a ROS-dependent RyR1 fragmentation in muscles of recreationally active subjects, and the resulting changes in muscle fiber Ca(2+)-handling trigger muscular adaptations. However, the same HIIT exercise does not cause RyR1 fragmentation in muscles of elite endurance athletes, which may explain why HIIT is less effective in this group.

  2. Ryanodine receptor fragmentation and sarcoplasmic reticulum Ca2+ leak after one session of high-intensity interval exercise

    Science.gov (United States)

    Place, Nicolas; Ivarsson, Niklas; Venckunas, Tomas; Neyroud, Daria; Brazaitis, Marius; Cheng, Arthur J.; Ochala, Julien; Kamandulis, Sigitas; Girard, Sebastien; Volungevičius, Gintautas; Paužas, Henrikas; Mekideche, Abdelhafid; Kayser, Bengt; Martinez-Redondo, Vicente; Bruton, Joseph; Truffert, Andre; Lanner, Johanna T.; Skurvydas, Albertas; Westerblad, Håkan

    2015-01-01

    High-intensity interval training (HIIT) is a time-efficient way of improving physical performance in healthy subjects and in patients with common chronic diseases, but less so in elite endurance athletes. The mechanisms underlying the effectiveness of HIIT are uncertain. Here, recreationally active human subjects performed highly demanding HIIT consisting of 30-s bouts of all-out cycling with 4-min rest in between bouts (≤3 min total exercise time). Skeletal muscle biopsies taken 24 h after the HIIT exercise showed an extensive fragmentation of the sarcoplasmic reticulum (SR) Ca2+ release channel, the ryanodine receptor type 1 (RyR1). The HIIT exercise also caused a prolonged force depression and triggered major changes in the expression of genes related to endurance exercise. Subsequent experiments on elite endurance athletes performing the same HIIT exercise showed no RyR1 fragmentation or prolonged changes in the expression of endurance-related genes. Finally, mechanistic experiments performed on isolated mouse muscles exposed to HIIT-mimicking stimulation showed reactive oxygen/nitrogen species (ROS)-dependent RyR1 fragmentation, calpain activation, increased SR Ca2+ leak at rest, and depressed force production due to impaired SR Ca2+ release upon stimulation. In conclusion, HIIT exercise induces a ROS-dependent RyR1 fragmentation in muscles of recreationally active subjects, and the resulting changes in muscle fiber Ca2+-handling trigger muscular adaptations. However, the same HIIT exercise does not cause RyR1 fragmentation in muscles of elite endurance athletes, which may explain why HIIT is less effective in this group. PMID:26575622

  3. Isospin properties of electric dipole excitations in Ca-48

    NARCIS (Netherlands)

    Derya, V.; Savran, D.; Endres, J.; Harakeh, M. N.; Hergert, H.; Kelley, J. H.; Papakonstantinou, P.; Pietralla, N.; Ponomarev, V. Yu.; Roth, R.; Rusev, G.; Tonchev, A. P.; Tornow, W.; Wortche, H. J.; Zilges, A.

    2014-01-01

    Two different experimental approaches were combined to study the electric dipole strength in the doubly-magic nucleus Ca-48 below the neutron threshold. Real-photon scattering experiments using bremsstrahlung up to 9.9 MeV and nearly mono-energetic linearly polarized photons with energies between

  4. Comparison of the TL intensity of the sintered composites of CaSO4+Tm

    International Nuclear Information System (INIS)

    Junot, O.D.; Sousa, F.L. de; Chagas, M.A.P.; Souza, D.N.

    2009-01-01

    The objective of this work is to compare the thermoluminescent intensity (TL) of CaSO 4 +Tm, CaSO 4 +Tm+glass and glass+Tm composites for use as thermoluminescent dosimeter (TLD). The route used to prepare the CaSO 4 +Tm and the CaSO 4 +Tm+glass was by mixing 1 g of CaSO 4 with 0.02 g of thulium oxide (99,9% purity) and 0.3 g of commercial and colorless glass. To mixing the composites were taken to a magnetic stirrer for 30 min with 10 mL of distilled water for better homogenization. The powder mixtures were dried in a stove at 100 deg C for 24 h. After drying, it was added polyvinyl alcohol (PVA) to improve the binding material. The pellets were compacted by application of an uniaxial pressing and sintered at 700 deg C/ 6 h. The route used in the preparation of glass+Tm pellets was similar to one previously mentioned, except by the use of 1 g of glass and 0.02 of Tm. After the sintering, the pellets dimensions were 1 mm thick and 6 mm in diameter. All samples were irradiated by a beta source ( 90 Sr + 90 Y) and received doses from 1.00 Gy to 20 Gy. Each composite presented a characteristic emission curve. The dosimeter of CaSO 4 +Tm+glass presented two peaks, the first at 115 deg C, and the second, very intense, ate 150 deg C. The CaSO 4 +Tm dosimeter showed a less intense peak at 140 deg C and another, more intense, at 235 deg C. In the composites of glass+Tm, the most intense peak has a thermoluminescent signal 94,04% lower than the most intense peak of CaSO 4 +Tm+glass and 81.57% lower than the most intense peak of CaSO 4 +Tm. After the analysis of TL emission curves, we observed that the CaSO 4 +Tm+glass have the highest TL intensity and a TL response proportional to the dose absorbed. (author)

  5. Pion-nucleus forward scattering amplitudes at Δ(3,3) energies for π+---12C, 40Ca and 48Ca

    International Nuclear Information System (INIS)

    Dragoset, W.H. Jr.

    1978-01-01

    Using the LAMPF P 3 channel, small angle elastic cross sections and total cross sections were measured for π +- -- 12 C, 40 Ca and 48 Ca at incident pion kinetic energies spanning the energy region of the Δ(3,3) resonance. The sigma/sub EL/ experiment employed a spectrometer consisting of two magnets and six MWPC to measure scattering angles and momenta. For the sigma/sub T/ experiment six MWPC were positioned about the target in the beam to measure the deflection or absorption of the incident pions. Both experiments monitored the Jacobian cusp of the π → μ + ν decay to achieve absolute normalization. The two complementary data sets allowed the nuclear forward scattering amplitudes, f/sub N/(0), to be completely determined. The sigma/sub EL/ data were fit by a phenomenological small angle scattering model developed by Bethe and modified by West and Yennie. Due to the presence of nuclear-Coulomb interference in the elastic cross sections, both the magnitude and sign of Re f/sub N/ were determined by the fits. The Re f/sub N/ results were used in the sigma/sub T/ analysis to calculate corrections for the nuclear and nuclear-Coulomb interference amplitudes. Im f/sub N/ was calculated from the sigma/sub T/ results via the optical theorem. The overall self-consistencies of the data were checked by inserting IM f/sub N/ as a fixed parameter into the sigma/sub EL/ fits and comparing the resulting Re f/sub N/ to the original Re f/sub N/. It was determined that Re f/sub N/(0) has a zero near 180 MeV for both 12 C and 40 Ca. For 48 Ca, however, the Re f/sub N/ obtained by fitting with the West-Yennie formula was quite charge dependent and did not exhibit a zero in the energy range investigated. The differences in the 40 Ca, 48 Ca total cross sections were compared to a simple Kisslinger optical model calculation. The model indicated that the RMS neutron radius of 48 Ca exceeds the proton radius by 0.10 +- 0.06 fm

  6. Improved limits on beta(-) and beta(-) decays of Ca-48

    Czech Academy of Sciences Publication Activity Database

    Bakalyarov, A.; Balysh, A.; Barabash, AS.; Beneš, P.; Briancon, C.; Brudanin, V. B.; Čermák, P.; Egorov, V.; Hubert, F.; Hubert, P.; Korolev, NA.; Kosjakov, VN.; Kovalík, Alojz; Lebedev, NA.; Novgorodov, A. F.; Rukhadze, NI.; Štekl, NI.; Timkin, VV.; Veleshko, IE.; Vylov, T.; Umatov, VI.

    2002-01-01

    Roč. 76, č. 9 (2002), s. 545-547 ISSN 0021-3640 Institutional research plan: CEZ:AV0Z1048901 Keywords : beta decay * double beta decay * Ca-48 Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.483, year: 2002

  7. Reaction Dynamics and Nuclear Structure Studies of n-Rich Nuclei Around 48Ca via Deep Inelastic Collisions with Heavy-Ions

    International Nuclear Information System (INIS)

    Leoni, S.

    2011-01-01

    The population and γ decay of neutron rich nuclei around 48 Ca has been measured at Legnaro National Laboratory with the PRISMA-CLARA setup, using deep-inelastic collisions on 64 Ni, at 5.9 MeV/A. The reaction properties of the main products are investigated, focusing on total cross-sections and energy integrated angular distributions. Gamma spectroscopy studies are also performed for the most intense transfer channels, making use of angular distributions and polarization measurements to firmly establish spin and parity of the excited states. In the case of 49 Ca candidates for particle-core couplings are investigated and interpreted on basis of lifetime measurements and comparison with model predictions. (author)

  8. Synthesis of the isotopes of elements 118 and 116 in the 249Cf and 245Cm+48Ca fusion reactions

    International Nuclear Information System (INIS)

    Oganessian, Y T; Utyonkov, V K; Lobanov, Y V; Abdullin, F S; Polyakov, A N; Sagaidak, R N; Shirokovsky, I V; Tsyganov, Y S; Voinov, A A; Gulbekian, G G; Bogomolov, S L; Gikal, B N; Mezentsev, A N; Iliev, S; Subbotin, V G; Sukhov, A M; Subotic, K; Zagrebaev, V I; Vostokin, G K; Itkis, M G; Moody, K J; . Patin, J B; Shaughnessy, D A; Stoyer, M A; Stoyer, N J; Wilk, P A; Kenneally, J M; Landrum, J H; Wild, J F; Lougheed, R W

    2006-01-01

    The decay properties of 290 116 and 291 116, and the dependence of their production cross sections on the excitation energies of the compound nucleus, 293 116, have been measured in the 245 Cm( 48 Ca,xn) 293-x 116 reaction. These isotopes of element 116 are the decay daughters of element 118 isotopes, which are produced via the 249 Cf+ 48 Ca reaction. They performed the element 118 experiment at two projectile energies, corresponding to 297 118 compound nucleus excitation energies of E* = 29.2 ± 2.5 and 34.4 ± 2.3 MeV. During an irradiation with a total beam dose of 4.1 x 10 19 48 Ca projectiles, three similar decay chains consisting of two or three consecutive α decays and terminated by a spontaneous fission (SF) with high total kinetic energy of about 230 MeV were observed. The three decay chains originated from the even-even isotope 294 118 (E α = 11.65 ± 0.06 MeV, T α = 0.89 -0.31 +1.07 ms) produced in the 3n-evaporation channel of the 249 Cf+ 48 Ca reaction with a maximum cross section of 0.5 -0.3 +1.6 pb

  9. Alpha clustering in Ti isotopes: 40,44,48Ca + α resonant scattering

    Directory of Open Access Journals (Sweden)

    Bailey Sam

    2016-01-01

    Full Text Available Measurements were made of the 4He(40,44,48Ca,α resonant scattering reactions at 180° and up to Ec.m. ~ 11.5MeV, using the Thick Target Inverse Kinematics technique. These measurements are discussed, with a focus on assessing their usefulness for investigating α-clustering in medium mass 44,48,52Ti nuclei.

  10. Experiments on the Synthesis of Element 115 in the Reaction ^{243}Am (^{48}Ca, xn)^{291-x}115

    CERN Document Server

    Oganessian, Yu T; Lobanov, Yu V; Abdullin, F S; Polyakov, A N; Shirokovsky, I V; Tsyganov, Yu S; Gulbekyan, G G; Bogomolov, S L; Mezentsev, A N; Iliev, S; Subbotin, V G; Sukhov, A M; Voinov, A A; Buklanov, G V; Subotic, K M; Zagrebaev, V I; Itkis, M G; Patin, J B; Moody, K J; Wild, J F; Stoyer, M A; Stoyer, N J; Shaughnessy, D A; Kenneally, J M; Lougheed, R W

    2003-01-01

    The results of experiments designed to synthesize element 115 isotopes in the ^{243}Am(^{48}Ca,xn)^{291-x}115 reaction are presented. With a beam dose of 4.3\\cdot 10^{18} 248-Mev ^{48}Ca projectiles, we observed three similar decay chains consisting of five consecutive alpha-decays, all detected in time intervals of about 20 s and terminated at a later time by a spontaneous fission with a high energy release (TKE \\sim 220 MeV). At a higher bombarding energy of 253 MeV, with an equal ^{48}Ca beam dose, we registered a different decay chain of four consecutive alpha-decays detected in a time interval of about 0.5 s, also terminated by spontaneous fission. The alpha-decay energies and half-lives for nine new alpha-decaying nuclei were determined. The decay properties of these synthesized nuclei are consistent with consecutive alpha-decays originating from the parent isotopes of the new element 115, ^{288}115 and ^{287}115, produced in the 3n- and 4n-evaporation channels with cross sections of about 3 and 1 pb, r...

  11. Study of the 249-251Cf + 48Ca reactions: recent results and outlook

    Science.gov (United States)

    Voinov, A. A.; Oganessian, Yu Ts; Abdullin, F. Sh; Brewer, N. T.; Dmitriev, S. N.; Grzywacz, R. K.; Hamilton, J. H.; Itkis, M. G.; Miernik, K.; Polyakov, A. N.; Roberto, J. B.; Rykaczewski, K. P.; Sabelnikov, A. V.; Sagaidak, R. N.; Shirokovsky, I. V.; Shumeiko, M. V.; Stoyer, M. A.; Subbotin, V. G.; Sukhov, A. M.; Tsyganov, Yu S.; Utyonkov, V. K.; Vostokin, G. K.

    2018-02-01

    Experiment aiming at the synthesis of heavy isotopes of Z=118 (Og) using beam of 48Ca and a target of 249-251Cf was undertaken in October 2015 - April 2016 employing the Dubna Gas-Filled Recoil Separator (FLNR JINR). The target of mixed isotopes of 249-251Cf (50.7% of 249Cf, 12.9% of 250Cf, and 36.4% of 251Cf) was irradiated by 48Ca ions at two beam energies of 252 and 258 MeV with the corresponding accumulated beam doses of 1.6×1019 and 1.1×1019. A single event observed at lower beam energy was assigned to the isotope 294Og, the product of the reaction 249Cf(48Ca, 3n); its decay pattern and the observed radioactive properties of the nuclides in the decay chain reproduce in full those observed for 294Og in our earlier experiments of 2002-2005 and 2012. At higher beam energy we observed no decay chains that could be attributed to the isotopes of Og. The possibility of renewal of this experiment in the future is discussed.

  12. Study of electric monopole transitions between the ground state and the first excited O+-state in 40,42,44,48Ca with high resolution inelastic electron scattering

    International Nuclear Information System (INIS)

    Strottman, D.; Graef, H.D.; Feldmeier, H.; Manakos, P.; Richter, A.; Spamer, E.

    1977-11-01

    Monopole transitions from the O + 1 ground states to O + 2 excited states at 3.353 MeV ( 40 Ca), 1.837 MeV ( 42 Ca), 1.884 MeV ( 44 Ca) and 4.272 Mev ( 48 Ca) have been investigated with high resolution inelastic electron scattering (FWHM approximately equal to 30 keV) at low momentum transfer (0.29 fm -1 -1 ). The respective monopole matrix elements are (2.53 +- 0.41) fm 2 , (5.24 +- 0.39) fm 2 , (5.45 +- 0.41) fm 2 and (2.28 +- 0.49) fm 2 . These results are used together with known ground state charge radii and the average number of holes in the sd-shell in the ground state to estimate the number of particle-hole excitations in the wavefunctions of th excited O + states. (orig.) [de

  13. Intense ${^31-35}$Ar beams produced with a nanostructured CaO target at ISOLDE

    CERN Document Server

    Ramos, J P; Mendonça, T M; Seiffert, C; Senos, A M R; Fynbo, H O U; Tengblad, O; Briz, J A; Lund, M V; Koldste, G T; Carmona-Gallardo, M; Pesudo, V; Stora, T

    2014-01-01

    At the ISOLDE facility at CERN, thick targets are bombarded with highly energetic pulsed protons to produce radioactive ion beams (RIBs). The isotopes produced in the bulk of the material have to diffuse out of the grain and effuse throughout the porosity of the material to a transfer line which is connected to an ionizer, from which the charged isotopes are extracted and delivered for physics experiments. Calcium oxide (CaO) powder targets have been used to produce mainly neutron deficient argon and carbon RIBs over the past decades. Such targets presented unstable yields, either decaying over time or low from the beginning of operation. These problems were suspected to come from the degradation of the target microstructure (sintering due to high temperature and/or high proton intensity). In this work, a CaO microstructural study in terms of sintering was conducted on a nanostructured CaO powder synthesized from the respective carbonate. Taking the results of this study, several changes were made at ISOLDE i...

  14. The proton spectral function of 40Ca and 48Ca studied with the (e,e'p) reaction

    International Nuclear Information System (INIS)

    Kramer, G.J.

    1990-01-01

    This thesis presents the results of an experimental study into the occupation of the orbitals around the Fermi level for 40 Ca and 48 Ca with quasi-elastic proton knock-out (e,e'p). Experiments have been carried out with the 500 MeV electron beam of the linear accelerator MEA at NIKHEF, Amsterdam. For 40 Ca the mechanism of the (e,e'p) reaction has been studied by comparing the measured momentum distributions of some strong transitions to discrete states in 39K , with various theoretical calculations. From this it has been concluded that uncertainties caused by deviations of the impulse approximation can be minimized if the measurements are carried out under parallel kinematical conditions. The spectroscopic strengths of the shell-model orbitals in states just below the Fermi level, for 40 Ca the 1d 3/2 , 1d 5/2 and 2s 1/2 orbitals, turned out to amount 50 to 70% of the IPSM limit. A small part of the missing strength has been found in the 1f 7/2 and 2p 3/2 orbitals which are just above the Fermi level (resp. 11 and 2% of the 2j+1 limit), which is an indication for ground state correlations. The spectroscopic strengths for the 1d 3/2 , 2s 1/2 and 1d 3/2 orbitals of 48 Ca turned out to be the same as for 40C a within the actual measuring accuracy. Above the Fermi level only strength in the 1f 7/2 orbital has been found (1% of the 2j+1 limit). The spectroscopic strengths determined with (e,e'p) experiments are about a factor two smaller than those obtained from (d, 3 He) experiments. This discrepancy has been studied by reviewing the model dependency of the DWBA analysis for the (d, 3 He) reaction with special emphasis on the sensitivities of the spectroscopic factors to the various approximations made in this theory. It is also investigated which part of the bound state wave function is probed by the (e,e'p) and the (d, 3 He) reactions in order to understand the model sensitivities arising from the exact shape of the bound state wave function. (H.W.).97 refs.; 48

  15. Neutron Skin Thickness of 48Ca from a Nonlocal Dispersive Optical-Model Analysis

    Science.gov (United States)

    Mahzoon, M. H.; Atkinson, M. C.; Charity, R. J.; Dickhoff, W. H.

    2017-12-01

    A nonlocal dispersive optical-model analysis has been carried out for neutrons and protons in 48Ca. Elastic-scattering angular distributions, total and reaction cross sections, single-particle energies, the neutron and proton numbers, and the charge distribution have been fitted to extract the neutron and proton self-energies both above and below the Fermi energy. From the single-particle propagator resulting from these self-energies, we have determined the charge and neutron matter distributions in 48Ca. A best fit neutron skin of 0.249 ±0.023 fm is deduced, but values up to 0.33 fm are still consistent. The energy dependence of the total neutron cross sections is shown to have a strong sensitivity to the skin thickness.

  16. Electrical dipole polarizability and spin M1 strength from {sup 48}Ca(p,p') data under 0; Elektrische Dipol-Polarisierbarkeit und Spin-M1-Staerke aus {sup 48}Ca(p,p')-Daten unter 0

    Energy Technology Data Exchange (ETDEWEB)

    Birkhan, Jonny Hubertus

    2016-07-01

    In this thesis, proton scattering data on the nucleus {sup 48}Ca at very forward angles had been analysed. The data stem from a measurement campaign which was launched at the Research Centre of Nuclear Physics at Osaka, Japan, in the past. One of the two objectives of this analysis was to extract a value for the static electric dipole polarisability from the isovector giant dipole resonance (IVGDR). The second objective was to extract the total electromagnetic M1 strength B(M1) of the spin-flip transition which excites the prominent 1{sup +} state at an excitation energy of E{sub x}=10.22 MeV. The polarisability was calculated from the distribution of photo-absorption cross sections within an energy range from E{sub x}=11 MeV to E{sub x}=26 MeV. The photo-absorption cross sections had been deduced from the distribution of E1 cross sections by the method of virtual photons. For this purpose the experimental cross sections had been deconvoluted by a multipole deconvolution into an E1 part and a background part. Then, the best estimate of the polarisability is given by α{sub D}=(1.36±0.14) fm{sup 3}. If a E3 model was included into the multipole decomposition of the (p,p') data the result increased up to α{sub D}=(1.50±0.09) fm{sup 3}. The deviation between these two results is mainly due to the fact that the multipole decomposition is very sensitive on the background function. Assuming that the the IVGDR of the nuclei {sup 48}Ca and {sup 40}Ca have approximately the same structure, estimates for the polarisability of the nucleus {sup 48}Ca could be drawn from {sup 40}Ca(γ,abs) data. Additionally, data from a {sup 48}Ca(e,e'n) measurement were used to estimate the polarisability of the nucleus {sup 48}Ca. Its polarisability seems to fall within the range of α{sub D}=(1.50±0.09) fm{sup 3} and α{sub D}=(1.69±0.03) fm{sup 3}. Beside this, it could be shown by the {sup 40}Ca data that a significant contribution to the polarisability has to be expected

  17. Study of the properties of the superheavy nuclei Z=117 produced in the 249Bk + 48Ca reaction

    International Nuclear Information System (INIS)

    Oganessian, Y.T.; Abdullin, F.S.; Dmitriev, S.N.; Itkis, M.G.; Polyakov, A.N.; Sagaidak, R.N.; Shirokovsky, I.V.; Shumeiko, M.V.; Subbotin, V.G.; Sukhov, A.M.; Tsyganov, Y.S.; Utyonkov, V.K.; Voinov, A.A.; Vostokin, G.K.; Alexander, C.; Binder, J.; Boll, R.A.; Ezold, J.; Felker, K.; Miernik, K.; Roberto, J.B.; Rykaczewski, K.P.; Gostic, J.M.; Henderson, R.A.; Moody, K.J.; Shaughnessy, D.H.; Stoyer, M.A.; Stoyer, N.J.; Grzywacz, R.K.; Miller, D.; Hamilton, J.H.; Ramayya, A.V.; Ryabinin, M.A.

    2014-01-01

    The reaction of 249 Bk with 48 Ca have been reinvestigated to provide new evidence for the discovery of element 117 on a larger number of events. The experiments were performed at five projectile energies and with a total beam dose of 48 Ca of about 4.6*10 19 . Two isotopes 293,294 117 were synthesized in the 249 Bk+ 48 Ca reaction, providing excitation functions and α-decay spectra of the produced isotopes that establishes these nuclei to be the products of the 4n- and 3n-evaporation channels, respectively. Decay properties of 293,294 117 and of all the daughter products agree with the data of the experiment in which these nuclei were synthesized for the first time in 2010. The new 289 115 events, populated by a decay of 293 117, demonstrate the same decay properties as those observed for 289 115 produced in the 243 Am( 48 Ca,2n) reaction thus providing cross-bombardment evidence. In addition, a single decay of 294 118 was observed from the reaction with 249 Cf - a result of the in-growth of 249 Cf in the 249 Bk target. (authors)

  18. Enrichment of natural calcium with 48 Ca by electromigration in molten salt

    International Nuclear Information System (INIS)

    Lagarde, G.; Bimbot, R.; Legoux, Y.

    1990-01-01

    A method for producing calcium enriched with 48 Ca by means of electromigration technique is presented. The aim of the study is the production of the calcium isotope for utilization in ion sources. The scheme of the electrolytic cell system and the operating parameters are presented. The reliability of the equipment and the experiments designed to evaluate the functional optimization of the system are examined. The obtention of calcium, with a factor of enrichment of approximately 10, from 225 g of Ca Br2 in 8 months is possible [fr

  19. Study of the (3He,t) reaction on 48Ca at 82 MeV

    International Nuclear Information System (INIS)

    Tanabe, T.; Yasue, M.; Sato, K.; Soga, F.; Igarashi, M.; Ogino, K.; Kadota, Y.; Saito, Y.; Shimokoshi, F.

    1978-01-01

    The reactions ( 3 He,t), ( 3 He, 3 He), ( 3 He,α) and ( 3 He,d) on 48 Ca have been studied at an incident energy of 82 MeV. The obtained angular distributions for the ( 3 He,t) reaction have been analyzed in terms of second-order DWBA theory, using a zero-range approximation. The relative ratio of the cross sections for the excitation of the fsub(7/2)f -1 sub(7/2) multiplets of 48 Sc could not be explained consistently by the one-step charge-exchange process only. However, the ratio was reproduced in order of magnitude by second-order DWBA calculations including the effect of two-step processes, such as ( 3 He-α-t) and ( 3 He-d-t) channels. The effects of the d- and α-channels on the elastic scattering of 3 He from 48 Ca were also examined in the framework of second-order full finite-range DWBA. (Auth.)

  20. 48Ca HETEROGENEITY IN DIFFERENTIATED METEORITES

    International Nuclear Information System (INIS)

    Chen, Hsin-Wei; Lee, Typhoon; Lee, Der-Chuen; Shen, Jason Jiun-San; Chen, Jiang-Chang

    2011-01-01

    Isotopic heterogeneities of 48 Ca have been found in numerous bulk meteorites that are correlated with 50 Ti and 54 Cr anomalies among differentiated planetary bodies, and the results suggest that a rare subset of neutron-rich Type Ia supernova (nSN Ia) was responsible for contributing these neutron-rich iron-group isotopes into the solar system (SS). The heterogeneity of these isotopes found in differentiated meteorites indicates that the isotopic compositions of the bulk SS are not uniform, and there are significant amounts of nSNe Ia dust incompletely mixed with the rest of SS materials during planetary formation. Combined with the data of now-extinct short-lived nuclide 60 Fe, which can be produced more efficiently from an nSN Ia than a Type II supernova ejecta, the observed planetary-scale isotopic heterogeneity probably reflects a late input of stellar dust grains with neutron-rich nuclear statistical equilibrium nuclides into the early SS.

  1. Enhanced bactericidal effect of enterocin AS-48 in combination with high-intensity pulsed-electric field treatment against Salmonella enterica in apple juice.

    Science.gov (United States)

    Martínez Viedma, Pilar; Sobrino López, Angel; Ben Omar, Nabil; Abriouel, Hikmate; Lucas López, Rosario; Valdivia, Eva; Martín Belloso, Olga; Gálvez, Antonio

    2008-12-10

    The effect of the broad spectrum cyclic antimicrobial peptide enterocin AS-48 combination with high-intensity pulsed-electric field (HIPEF) treatment (35 kV/cm, 150 Hz, 4 micros and bipolar mode) was tested on Salmonella enterica CECT 915 in apple juice. A response surface methodology was applied to study the bactericidal effects of the combined treatment. The process variables were AS-48 concentration, temperature, and HIPEF treatment time. While treatment with enterocin AS-48 alone up to 60 microg/ml had no effect on the viability of S. enterica in apple juice, an increased bactericidal activity was observed in combination with HIPEF treatments. Survival fraction was affected by treatment time, enterocin AS48 concentration and treatment temperature. The combination of 100 micros of HIPEF treatment, 30 microg/ml of AS-48, and temperature of 20 degrees C resulted in the lowest inactivation, with only a 1.2-log reduction. The maximum inactivation of 4.5-log cycles was achieved with HIPEF treatment for 1000 micros in combination with 60 microg/ml of AS-48 and a treatment temperature of 40 degrees C. Synergism between enterocin AS-48 and HIPEF treatment depended on the sequence order application, since it was observed only when HIPEF was applied in the presence of previously-added bacteriocin. The combined treatment could improve the safety of freshly-made apple juice against S. enterica transmission.

  2. Confirmation Of Super Heavy Element Production In 48Ca Induced Fusion Reactions A Handshake Of Physics And Chemistry For Element 112

    International Nuclear Information System (INIS)

    Hofmann, S.; Ackermann, D.; Burkhard, H. G.; Heinz, S.; Hessberger, F. P.; Khuyagbaatar, J.; Kindler, B.; Kojouharov, I.; Lommel, B.; Mann, R.; Muenzenberg, G.; Schoett, H. J.; Sulignano, B.; Antalic, S.; Saro, S.; Streicher, B.; Venhart, M.; Yeremin, A. V.; Comas, V. F.; Heredia, J. A.

    2008-01-01

    The production of 283 112 in 48 Ca induced nuclear reactions was investigated using physical and chemical separation techniques. In the reaction 48 Ca on 238 U, four events were registered at the SHIP velocity filter. The mean atomic mass of the evaporation residues (EVR)

  3. Nuclear density distributions of 40,42,44,48Ca from elastic scattering of 104 MeV alpha particles

    International Nuclear Information System (INIS)

    Gils, H.J.; Friedman, E.; Majka, Z.

    1979-12-01

    The elastic scattering of 104 MeV α particles from 40 , 42 , 44 , 48 Ca has been analyzed by a single folding model with a density dependent effective interaction. Nuclear density distributions have been extracted using various descriptions including Fourier-Bessel series which distinctly reduces the model dependence of the results and enables realistic estimates of errors. Differences of the density shapes of the Ca-isotopes are well determined showing evidence for a neutron skin in 48 Ca. The resulting root mean square radii are compared to the results obtained from other methods. The sensitivity and limitations of various methods are discussed. (orig.) 891 KBE/orig. 892 BRE

  4. Production and decay of the heaviest odd-Z nuclei in the 249Bk + 48Ca reaction

    International Nuclear Information System (INIS)

    Oganessian, Yu Ts; Abdullin, F Sh; Dmitriev, S N; Itkis, M G; Polyakov, A N; Alexander, C; Binder, J; Boll, R A; Ezold, J; Felker, K; Grzywacz, R K; Miernik, K; Roberto, J B; Gostic, J M; Henderson, R A; Moody, K J; Hamilton, J H; Ramayya, A V; Miller, D; Ryabinin, M A

    2015-01-01

    The reaction of 249 Bk with 48 Ca has been investigated with an aim of synthesizing and studying the decay properties of isotopes of the new element 117. The experiments were performed at five projectile energies (in two runs, in 2009-2010 and 2012) and with a total beam dose of 48 Ca ions of about 9x10 19 The experiments yielded data on a-decay characteristics and excitation functions of the produced nuclei that establish these to be 293 117 and 294 117 – the products of the 4n- and 3n-evaporation channels, respectively. In total, we have observed 20 decay chains of Z=117 nuclides. The cross sections were measured to be 1.1 pb for the 3n and 2.4 pb for the 4n-reaction channel. The new 289 115 events, populated by α decay of 117, demonstrate the same decay properties as those observed for 115 produced in the 243 Am( 48 Ca,2n) reaction thus providing cross-bombardment evidence. In addition, a single decay of 294 118 was observed from the reaction with 249 Cf – a result of the in-growth of 249 Cf in the 249 Bk target. The observed decay chain of 294 118 is in good agreement with decay properties obtained in 2002-2005 in the experiments with the reaction 249 Cf( 48 Ca,3n) 294 118. The energies and half-lives of the odd-Z isotopes observed in the 117 decay chains together with the results obtained for lower-Z superheavy nuclei demonstrate enhancement of nuclear stability with increasing neutron number towards the predicted new magic number N=184

  5. Molecular cloning of the large subunit of the high-Ca2+-requiring form of human Ca2+-activated neutral protease

    International Nuclear Information System (INIS)

    Imajoh, Shinobu; Aoki, Kazumasa; Ohno, Shigeo; Emori, Yasufumi; Kawasaki, Hiroshi; Sugihara, Hidemitsu; Suzuki, Koichi

    1988-01-01

    A nearly full-length cDNA clone for the large subunit of high-Ca 2+ -requiring Ca 2+ -activated neutral protease (mCANP) from human tissues has been isolated. The deduced protein, determined for the first time as an mCANP, has essentially the same structural features as those revealed previously for the large subunits of the low-Ca 2+ -requiring form (μCANP). Namely, the protein, comprising 700 amino acid residues, is characterized by four domains, containing a cysteine protease like domain and a Ca 2+ -binding domain. The overall amino acid sequence similarities of the mCANP large subunit with those of human μCANP and chicken CANP are 62% and 66%, respectively. These values are slightly lower than that observed between μCANP and chicken CANP (70%). Local sequence similarities vary with the domain, 73-78% in the cysteine protease like domain and 48-65% in the Ca 2+ -binding domain. These results suggest that CANPs with different Ca 2+ sensitivities share a common evolutionary origin and that their regulatory mechanisms are similar except for the Ca 2+ concentrations required for activation

  6. Aspirin exerts high anti-cancer activity in PIK3CA-mutant colon cancer cells.

    Science.gov (United States)

    Gu, Mancang; Nishihara, Reiko; Chen, Yang; Li, Wanwan; Shi, Yan; Masugi, Yohei; Hamada, Tsuyoshi; Kosumi, Keisuke; Liu, Li; da Silva, Annacarolina; Nowak, Jonathan A; Twombly, Tyler; Du, Chunxia; Koh, Hideo; Li, Wenbin; Meyerhardt, Jeffrey A; Wolpin, Brian M; Giannakis, Marios; Aguirre, Andrew J; Bass, Adam J; Drew, David A; Chan, Andrew T; Fuchs, Charles S; Qian, Zhi Rong; Ogino, Shuji

    2017-10-20

    Evidence suggests that nonsteroidal anti-inflammatory drug aspirin (acetylsalicylic acid) may improve patient survival in PIK3CA -mutant colorectal carcinoma, but not in PIK3CA -wild-type carcinoma. However, whether aspirin directly influences the viability of PIK3CA -mutant colon cancer cells is poorly understood. We conducted in vitro experiments to test our hypothesis that the anti-proliferative activity of aspirin might be stronger for PIK3CA -mutant colon cancer cells than for PIK3CA -wild-type colon cancer cells. We measured the anti-proliferative effect of aspirin at physiologic concentrations in seven PIK3CA -mutant and six PIK3CA -wild-type human colon cancer cell lines. After exposure to aspirin, the apoptotic index and cell cycle phase of colon cancer cells were assessed. In addition, the effect of aspirin was examined in parental SW48 cells and SW48 cell clones with individual knock-in PIK3CA mutations of either c.3140A>G (p.H1047R) or c.1633G>A (p.E545K). Aspirin induced greater dose-dependent loss of cell viability in PIK3CA -mutant cells than in PIK3CA -wild-type cells after treatment for 48 and 72 hours. Aspirin treatment also led to higher proportions of apoptotic cells and G0/G1 phase arrest in PIK3CA -mutant cells than in PIK3CA -wild-type cells. Aspirin treatment of isogenic SW48 cells carrying a PIK3CA mutation, either c.3140A>G (p.H1047R) or c.1633G>A (p. E545K), resulted in a more significant loss of cell viability compared to wild-type controls. Our findings indicate that aspirin causes cell cycle arrest, induces apoptosis, and leads to loss of cell viability more profoundly in PIK3CA -mutated colon cancer cells than in PIK3CA -wild-type colon cancer cells. These findings support the use of aspirin to treat patients with PIK3CA -mutant colon cancer.

  7. Photoemission study of Ca-intercalated graphite superconductor CaC6

    International Nuclear Information System (INIS)

    Okazaki, Hiroyuki; Yoshida, Rikiya; Iwai, Keisuke; Noami, Kengo; Muro, Takayuki; Nakamura, Tetsuya; Wakita, Takanori; Muraoka, Yuji; Hirai, Masaaki; Tomioka, Fumiaki; Takano, Yoshihiko; Takenaka, Asami; Toyoda, Masahiro; Oguchi, Tamio; Yokoya, Takayoshi

    2010-01-01

    In this work, we have performed resonant photoemission studies of Ca-intercalated graphite superconductor CaC 6 . Using photon energy of the Ca 2p-3d threshold, the photoemission intensity of the peak at Fermi energy (E F ) is resonantly enhanced. This result provides spectroscopic evidence for the existence of Ca 3d states at E F , and strongly supports that Ca 3d state plays a crucial role for the superconductivity of this material with relatively high T c .

  8. Production and acceleration of Ca-beams with the ECR source in the Jinr-Ganil experiment

    International Nuclear Information System (INIS)

    Lukyanov, S.M.; Artukh, A.G.; Gvozdev, B.A.; Kutner, V.B.; Penionzhkevich, Y.E.; Bex, L.; Bourgarel, M.P.; Ferme, J.

    1989-01-01

    The results of production and acceleration of 48 Ca-beams with the ECR-source are described. For this purpose a special technique has been developed which allows the metal to be extracted from the oxide with the aluminium as an acceptor. The mean rate of consumption of 48 Ca was about 2 mg/h and the beam intensity was about 15μA on charge state 6. The method for recuperation of used calcium is presented

  9. High-spin states of 39K and 42Ca, ch. 4

    International Nuclear Information System (INIS)

    Eggenhuisen, H.H.; Elstrom, L.P.; Engelbertink, G.A.P.; Aarts, H.J.M.

    1978-01-01

    High-spin states of 39 K and 42 Ca have been investigated with the 28 Si( 16 O, αpγ) 39 K and 28 Si( 16 O, 2pγ) 42 Ca reactions at a beam energy of 45 MeV. Gamma-gamma coincidence, γ-ray angular distribution and linear polarization measurements were performed with a Ge(Li)-NaI(Tl) Compton suppression spectrometer and a three-crystal Ge(Li) Compton polarimeter. High-spin states of 39 K at Esub(x)=7.14, 7.78 and 8.03 and of 42 Ca at Esub(x)=7.75 MeV are established. Unambiguous spin-parity assignments of Jsup(π)=11/2 - , 13/2 - , 15/2 + , 15/2 - , 17/2 + and 19/2 - to the 39 K levels at Esub(x)=5.35, 5.72, 6.48, 7.14, 7.78 and 8.03 MeV and of 6 - , 7 - , 8 - , 9 - and (8,10) to the 42 Ca levels at Esub(x)=5.49, 6.15, 6.41, 6.55 and 7.37 MeV, respectively, have been obtained. Further spin-parity restrictions, lifetime limits, excitation energies, branching ratios and multipole mixing ratios are reported. Discrepancies with previous Jsup(π) assignments are discussed in detail. (Auth.)

  10. Characterization of detergent-solubilized sarcoplasmic reticulum Ca2+-ATPase by high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Andersen, J.P.; Vilsen, B.; Nielsen, H.; Moller, J.V.

    1986-01-01

    Sarcoplasmic reticulum Ca 2+ -ATPase solubilized by the nonionic detergent octaethylene glycol monododecyl ether was studied by molecular sieve high-performance liquid chromatography (HPLC) and analytical ultracentrifugation. Significant irreversible aggregation of soluble Ca 2+ -ATPase occurred within a few hours in the presence of ≤ 50 μM Ca 2+ . The aggregates were inactive and were primarily held together by hydrophobic forces. In the absence of reducing agent, secondary formation of disulfide bonds occurred. The stability of the inactive dimer upon dilution permitted unambiguous assignment of its elution position and sedimentation coefficient. At high 45 Ca 2+ concentration (500 μM), monomeric Ca 2+ -ATPase was stable for several house. Reversible self-association induced by variation in protein, detergent, and lipid concentrations was studied by large-zone HPLC. The association constant for dimerization of active Ca 2+ -ATPase was found to be 10 5 -10 6 M -1 depending on the detergent concentration. More detergent was bound to monomeric than to dimeric Ca 2+ -ATPase, even above the critical micellar concentration of the detergent. Binding of Ca 2+ and 48 V vanadate as well as ATP-dependent phosphorylation was studied in monomeric and in reversibly associated dimeric preparations. In both forms, two high-affinity Ca 2+ binding sites per phosphorylation site existed. The delipidated monomer purified by HPLC was able to form ADP-insensitive phosphoenzyme and to bind ATP and vanadate simultaneously. The results suggest that formation of Ca 2+ -ATPase oligomers in the membrane is governed by nonspecific forces (low affinity) and that each polypeptide chain constitutes a functional unit

  11. Ca isotopes in refractory inclusions

    International Nuclear Information System (INIS)

    Niederer, F.R.; Papanastassiou, D.A.

    1984-01-01

    We report measurements of the absolute isotope abundance of Ca in Ca-Al-rich inclusions from the Allende and Leoville meteorites. Improved high precision measurements are reported also for 46 Ca. We find that nonlinear isotope effects in Ca are extremely rare in these inclusions. The absence of nonlinear effects in Ca, except for the effects in FUN inclusions, is in sharp contrast to the endemic effects in Ti. One fine-grained inclusion shows an excess of 46 Ca of (7 +- 1) per mille, which is consistent with addition of only 46 Ca or of an exotic (*) component with 46 Ca* approx. 48 Ca*. FUN inclusion EK-1-4-1 shows a small 46 Ca excess of (3.3 +- 1.0) per mille; this confirms that the exotic Ca components in EK-1-4-1 were even more deficient in 46 Ca relative to 48 Ca than is the case for normal Ca. The Ca in the Ca-Al-rich inclusions shows mass dependent isotope fractionation effects which have a range from -3.8 to +6.7 per mille per mass unit difference. This range is a factor of 20 wider than the range previously established for bulk meteorites and for terrestrial and lunar samples. Ca and Mg isotope fractionation effects in the Ca-Al-rich inclusions are common and attributed to kinetic isotope effects. (author)

  12. Isospin properties of electric dipole excitations in 48Ca

    Science.gov (United States)

    Derya, V.; Savran, D.; Endres, J.; Harakeh, M. N.; Hergert, H.; Kelley, J. H.; Papakonstantinou, P.; Pietralla, N.; Ponomarev, V. Yu.; Roth, R.; Rusev, G.; Tonchev, A. P.; Tornow, W.; Wörtche, H. J.; Zilges, A.

    2014-03-01

    Two different experimental approaches were combined to study the electric dipole strength in the doubly-magic nucleus 48Ca below the neutron threshold. Real-photon scattering experiments using bremsstrahlung up to 9.9 MeV and nearly mono-energetic linearly polarized photons with energies between 6.6 and 9.51 MeV provided strength distribution and parities, and an (α,α‧γ) experiment at Eα=136 MeV gave cross sections for an isoscalar probe. The unexpected difference observed in the dipole response is compared to calculations using the first-order random-phase approximation and points to an energy-dependent isospin character. A strong isoscalar state at 7.6 MeV was identified for the first time supporting a recent theoretical prediction.

  13. On the possibility to measure 0νββ-decay nuclear matrix element for 48Ca

    International Nuclear Information System (INIS)

    Rodin, Vadim

    2011-01-01

    As shown in Ref. [2], the Fermi part M F 0ν of the total 0νββ-decay nuclear matrix element M 0ν can be related to the single Fermi transition matrix element between the isobaric analog state (IAS) of the ground state of the initial nucleus and the ground state of the final nucleus. The latter matrix element could be measured in charge-exchange reactions. Here we discuss a possibility of such a measurement for 48 Ca and estimate the cross-section of the reaction 48 Ti(n,p) 48 Sc(IAS).

  14. Accessing the nuclear symmetry energy in Ca+Ca collisions

    Directory of Open Access Journals (Sweden)

    Chbihi A.

    2012-07-01

    Full Text Available The status of the analysis of the INDRA-VAMOS experiement performed at GANIL, using the reactions 40,48Ca+40,48Ca reactions at 35AMeV, are presented. Isotopic distributions of fragments produced in multifragmentation events provide information on the importance of the surface term contribution in the symmetry energy by comparison to AMD predictions.

  15. The sup(40,44,48)Ca(3He, 3He) and (3He, 4He) reactions at 50 MeV

    International Nuclear Information System (INIS)

    Griffiths, R.J.; Duggan, F.; Clarke, N.M.

    1981-01-01

    Measurements have been made of the ( 3 He, 3 He) and ( 3 He, 4 He) reactions on the isotopes of calcium 40 Ca, 44 Ca and 48 Ca at an energy of 50.4 MeV. The results have been analysed with conventional optical potentials and DWBA. The adequacy of the former and inadequacy of the latter for reactions with composite particles is discussed. (author)

  16. High-pressure compressibility and vibrational properties of (Ca,Mn)CO 3

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jin; Caracas, Razvan; Fan, Dawei; Bobocioiu, Ema; Zhang, Dongzhou; Mao, Wendy L.

    2016-12-01

    Knowledge of potential carbon carriers such as carbonates is critical for our understanding of the deep-carbon cycle and related geological processes within the planet. Here we investigated the high-pressure behavior of (Ca,Mn)CO3 up to 75 GPa by synchrotron single-crystal X-ray diffraction, laser Raman spectroscopy, and theoretical calculations. MnCO3-rich carbonate underwent a structural phase transition from the CaCO3-I structure into the CaCO3-VI structure at 45–48 GPa, while CaCO3-rich carbonate transformed into CaCO3-III and CaCO3-VI at approximately 2 and 15 GPa, respectively. The equation of state and vibrational properties of MnCO3-rich and CaCO3-rich carbonates changed dramatically across the phase transition. The CaCO3-VI-structured CaCO3-rich and MnCO3-rich carbonates were stable at room temperature up to at least 53 and 75 GPa, respectively. The addition of smaller cations (e.g., Mn2+, Mg2+, and Fe2+) can enlarge the stability field of the CaCO3-I phase as well as increase the pressure of the structural transition into the CaCO3-VI phase.

  17. Thermoluminescent characteristics of CaSO4:Dy+PTFE irradiated with high energy electron beams

    International Nuclear Information System (INIS)

    Alvarez, R.; Rivera, T.; Calderon, J. A.; Jimenez, Y.; Rodriguez, J.; Oviedo, O.; Azorin, J.

    2011-10-01

    In the present work thermoluminescent response of dysprosium doped calcium sulfate embedded in polytetrafluorethylene (CaSO 4 :Dy+PTFE) under high electron beam irradiations from linear accelerator for clinical applications was investigated. The irradiations were carried out using high electron beams (6 to 18 MeV) from a linear accelerator Varian, C linac 2300C/D, for clinical practice purpose. The electron irradiations were obtained by using the water solid in order to guarantee electronic equilibrium conditions. Field shaping for electron beams was obtained with electron cones. Glow curve and other thermoluminescent characteristics of CaSO 4 :Dy+PTFE were conducted under high electron beams irradiations. The thermoluminescent response of the pellets showed and intensity peak centered at around 235 C. Thermoluminescent response of CaSO 4 :Dy+PTFE as a function of high electron absorbed dose showed a linearity in a wide range. To obtain reproducibility characteristic, a set of pellets were exposed repeatedly for the same electron absorbed dose. The results obtained in this study can suggest the applicability of CaSO 4 :Dy+PTFE pellets for high electron beam dosimetry, provided fading is correctly accounted for. (Author)

  18. Ca²⁺ signal contributing to the synthesis and emission of monoterpenes regulated by light intensity in Lilium 'siberia'.

    Science.gov (United States)

    Hu, Zenghui; Li, Tianjiao; Zheng, Jian; Yang, Kai; He, Xiangfeng; Leng, Pingsheng

    2015-06-01

    The floral scent is an important part of plant volatile compounds, and is influenced by environmental factors. The emission of monoterpenes of Lilium 'siberia' is regulated by light intensity, but the mechanism is large unknown. In this study, the expression of Li-mTPS, a monoterpene synthase gene in the tepals of Lilium 'siberia', and net Ca(2+) flux were investigated after exposure to different levels of light intensity (0, 100, 300, 600, 1000, and 1500 μmol m(-2) s(-1)). Moreover the effect of LaCl3 and ethylene glycol-bis-(2-aminoethylether)-N,N,N',N'-tetraacetic acid (EGTA) on the Li-mTPS expression, monoterpene emission, and net Ca(2+) flux were examined at 600 μmol m(-2) s(-1). The results showed that along with the enhancement of light intensity, the expression level of Li-mTPS increased gradually, and the net Ca(2+) influx was also enhanced showing a similar pattern. It was found that LaCl3 and EGTA effectively inhibited the increase in expression of Li-mTPS and the net Ca(2+) influx induced by light treatment. Moreover, the release amounts of monoterpenes decreased significantly after treatment with LaCl3 and EGTA. So it can be concluded that Ca(2+) signal contributed to the biosynthesis and emission of monoterpenes regulated by light intensity in Lilium 'siberia' tepals. The increased light intensity firstly triggered the Ca(2+) influx to cytoplasm, and then the gene expression of monoterpene synthases downstream was activated to regulate the biosynthesis and emission of monoterpenes. But in the signaling pathway other mechanisms were thought to be involved in the emission of monoterpenes regulated by light intensity, which need to be investigated in future research. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  19. Determination of Mo- and Ca-isotope ratios in Ca100MoO4 crystal for AMoRE-I experiment

    Science.gov (United States)

    Karki, S.; Aryal, P.; Kim, H. J.; Kim, Y. D.; Park, H. K.

    2018-01-01

    The first phase of the AMoRE (Advanced Mo-based Rare process Experiment) is to search for neutrinoless double-beta decay of 100Mo with calcium molybdate (Ca100MoO4) crystals enriched in 100Mo and depleted in 48Ca using a cryogenic technique at Yangyang underground laboratory in Korea. It is important to know 100Mo- and 48Ca-isotope ratios in Ca100MoO4 crystal to estimate half-life of 100Mo decays and to 2 νββ background from 48Ca. We employed the ICP-MS (Inductive Coupled Plasma Mass Spectrometer) to measure 100Mo- and 48Ca-isotope ratios in Ca100MoO4 crystal. The measured results for 100Mo- and 48Ca-isotope ratios in the crystal are (94 . 6 ± 2 . 8) % and (0 . 00211 ± 0 . 00006) %, respectively, where errors are included both statistical and systematic uncertainties.

  20. Study of very neutron-rich nuclei produced by means of a 48Ca beam

    International Nuclear Information System (INIS)

    Lewitowicz, M.; Artukh, A.G.

    1991-01-01

    The results of experiments with a 48 Ca beam performed at GANIL are presented and discussed. More than 30 very neutron-rich isotopes were identified or studied for the first time. The evidence for particle-unstable character of the 26 O isotope is reported. Half-life measurements for light neutron rich nuclei are compared with different theoretical predictions. (author) 14 refs.; 6 figs.; 1 tab

  1. Low-lying dipole response in the stable 40,48Ca nuclei within the second random-phase approximation

    International Nuclear Information System (INIS)

    Gambacurta, D.; Grasso, M.; Catara, F.

    2012-01-01

    The low-lying dipole strength distributions of 40 CaCa and 48 Ca, in the energy region between 5 and 10 MeV, are studied within the second random phase approximation (RPA) with Skyrme interaction. Standard RPA models do not usually predict any presence of strength in this energy region, while experimentally a significant amount of strength is found. The inclusion of the 2 particle −2 hole configurations allows to obtain a description in a rather good agreement with the experimental data. The properties of the most collective state are analyzed in terms of its 1 particle −1 hole nature and its transition densities.

  2. Low-lying dipole response in the stable 40,48Ca nuclei within the second random-phase approximation

    Science.gov (United States)

    Gambacurta, D.; Grasso, M.; Catara, F.

    2012-10-01

    The low-lying dipole strength distributions of 40CaCa and 48Ca, in the energy region between 5 and 10 MeV, are studied within the second random phase approximation (RPA) with Skyrme interaction. Standard RPA models do not usually predict any presence of strength in this energy region, while experimentally a significant amount of strength is found. The inclusion of the 2 particle -2 hole configurations allows to obtain a description in a rather good agreement with the experimental data. The properties of the most collective state are analyzed in terms of its 1 particle -1 hole nature and its transition densities.

  3. Spin excitations in 48Ca and 90Zr with 319 MeV protons

    International Nuclear Information System (INIS)

    Nanda, S.K.

    1985-05-01

    Cross sections, analyzing powers, and spin-flip probabilities have been measured in the low momentum transfer region in the 90 Zr(p vector, p' vector) 90 Zr* reaction at 319 MeV. A rich fine structure is observed for the first time in inelastic proton scattering in the previously proposed M1 giant resonance region. Angular distribution of most of these states are consistent with M1 excitation. The excitation energies of the fine structure states are in good agreement with similar structure seen in electron scattering; however, discrepancies in spin assignments remain. The measured cross section for the entire bump is about 37 +- 10% of the Distorted Wave Impulse Approximation (DWIA) prediction for the M1 strength in 90 Zr with simple wave functions. However, an analysis of the fine structure states reveals about 15% of the strength in the M1 region to be due to narrow El states; another 8% is attributed to M2 strength. The spin-flip measurements for 90 Zr reveal a large spin-flip probability value for the M1 region; good agreement is obtained with DWIA calculations. However, a large cross section for spin excitations distributed uniformly over the excitation energy region from about 7 to 25 MeV is observed for the first time. The spin excitation strength in this giant resonance continuum is found to about 0.80 mb/sr/MeV. Angular distributions for the spin-flip cross sections from 7 to 18 MeV in steps of 2 MeV have been analyzed with low multipole spin excitation calculations in the DWIA framework; the observed spin-flip strength in this region is found to be consistent with spin excitation involving angular momentum transfer of up to two. Finally, cross section, analyzing power, and spin-flip probability data have also been obtained for the 10.23 MeV M1 transition in the 48 Ca(p vector, p' vector) 48 Ca* reaction at 319 MeV. The quenching of M1 strength in 48 Ca relative to theoretical predictions is found to be consistent with previous work

  4. New High Pressure Phase of CaCO3: Implication for the Deep Diamond Formation

    Science.gov (United States)

    Mao, Z.; Li, X.; Zhang, Z.; Lin, J. F.; Ni, H.; Prakapenka, V.

    2017-12-01

    Surface carbon can be transported to the Earth's deep interior through sinking subduction slabs. Carbonates, including CaCO3, MgCO3 and MgCa(CO3)2, are important carbon carriers for the deep carbon cycle. Experimental studies on the phase stability of carbonates with coexisting mantle minerals at relevant pressure and temperature conditions are thus important for understanding the deep carbon cycle. In particular, recent petrological studies have revealed the evidence for the transportation of CaCO3 to the depth at least of the top lower mantle by analyzing the diamond inclusions. Yet the phase stability of CaCO3 at relevant pressure and temperature conditions of the top lower mantle is still unclear. Previous single-crystal study has shown that CaCO3 transforms from the CaCO3-III structure to CaCO3-VI at 15 GPa and 300 K. The CaCO3-VI is stable at least up to 40 GPa at 300 K. At high temperatures, CaCO3 in the aragonite structure will directly transform into the post-aragonite structure at 40 GPa. However, a recent theoretical study predicted a new phase of CaCO3 with a space group of P21/c between 32 and 48 GPa which is different from previous experimental results. In this study, we have investigated the phase stability of CaCO3 at high pressure-temperature conditions using synchrotron X-ray diffraction in laser-heated diamond anvil cells. We report the discovery of a new phase of CaCO3 at relevant pressure-temperature conditions of the top lower mantle which is consistent with previous theoretical predictions. This new phase is an important carrier for the transportation of carbon to the Earth's lower mantle and crucial for growing deep diamonds in the region.

  5. Isospin properties of electric dipole excitations in {sup 48}Ca

    Energy Technology Data Exchange (ETDEWEB)

    Derya, V., E-mail: derya@ikp.uni-koeln.de [Institut für Kernphysik, Universität zu Köln, 50937 Köln (Germany); Savran, D. [ExtreMe Matter Institute EMMI and Research Division, GSI, 64291 Darmstadt (Germany); Frankfurt Institute for Advanced Studies FIAS, 60438 Frankfurt am Main (Germany); Endres, J. [Institut für Kernphysik, Universität zu Köln, 50937 Köln (Germany); Harakeh, M.N. [Kernfysisch Versneller Instituut, University of Groningen, 9747 AA Groningen (Netherlands); GANIL, CEA/DSM-CNRS/IN2P3, 14076 Caen (France); Hergert, H. [Department of Physics, Ohio State University, Columbus, OH 43210 (United States); Kelley, J.H. [Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Department of Physics, North Carolina State University, Raleigh, NC 27695 (United States); Papakonstantinou, P. [Rare Isotope Science Project, Institute for Basic Science, Daejeon 305-811 (Korea, Republic of); Pietralla, N.; Ponomarev, V.Yu.; Roth, R. [Institut für Kernphysik, TU Darmstadt, 64289 Darmstadt (Germany); Rusev, G.; Tonchev, A.P.; Tornow, W. [Department of Physics, Duke University, Durham, NC 27708 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Wörtche, H.J. [Kernfysisch Versneller Instituut, University of Groningen, 9747 AA Groningen (Netherlands); Zilges, A. [Institut für Kernphysik, Universität zu Köln, 50937 Köln (Germany)

    2014-03-07

    Two different experimental approaches were combined to study the electric dipole strength in the doubly-magic nucleus {sup 48}Ca below the neutron threshold. Real-photon scattering experiments using bremsstrahlung up to 9.9 MeV and nearly mono-energetic linearly polarized photons with energies between 6.6 and 9.51 MeV provided strength distribution and parities, and an (α,α{sup ′}γ) experiment at E{sub α}=136MeV gave cross sections for an isoscalar probe. The unexpected difference observed in the dipole response is compared to calculations using the first-order random-phase approximation and points to an energy-dependent isospin character. A strong isoscalar state at 7.6 MeV was identified for the first time supporting a recent theoretical prediction.

  6. Accurate measurement of stable isotopes 46Ca and 48Ca in human feces, plasma, and urine in relation to human nutrition of calcium

    International Nuclear Information System (INIS)

    Janghorbani, M.; Sundaresan, A.; Young, V.R.

    1981-01-01

    A method based on Radiochemical Neutron Activation Analysis (RNAA) is described which allows simultaneous measurement of two stable isotopes of calcium, 46 Ca and 48 Ca, in human feces, plasma, and urine for the purpose of studying human nutrition and metabolism of calcium. It is shown that these measurements can be made with relative analytical precision of 1-5% depending on the particulars of a given experiment. The method has been applied in humans and data are given showing that kinetics of plasma appearance of 46 Ca administered orally with food can be readily investigated. This method allows investigation of a number of important nutritional and metabolic issues in all human population groups without regard to radioisotope safety considerations, and should prove especially helpful in relation to studies of calcium bioavailability from different foods in a variety of population groups for whom use of radiocalcium is not warranted. (Auth.)

  7. Production of heavy evaporation residues in the reactions induced by an extracted 48Ca beam on a 208Pb target

    International Nuclear Information System (INIS)

    Eremin, A.V.; Chepigin, V.I.; Itkis, M.G.

    1998-01-01

    The production cross sections of the isotopes 253-255 No were measured for the heavy ion complete fusion reaction 48 Ca + 208 Pb using the electrostatic recoil separator VASSILISSA. The obtained excitation functions for the reaction products formed after the evaporation of 1-3 neutrons from the compound nucleus are discussed and compared with the data obtained earlier and with the results of the statistical model calculations. The background conditions at the extraction of the correlated events of the reaction product decay are also considered from the point of view of future experiments on the superheavy element synthesis in the complete fusion reactions induced by 48 Ca projectiles

  8. Isospin aspects in nuclear reactions involving Ca beams at 25 MeV/nucleon

    Energy Technology Data Exchange (ETDEWEB)

    Lombardo, I., E-mail: ilombardo@lns.infn.it; Agodi, C.; Alba, R.; Amorini, F.; Anzalone, A. [INFN Laboratori Nazionali del Sud (Italy); Auditore, L. [Universita di Messina, and INFN-Gr. Coll. Messina, Dipartimento di Fisica (Italy); Berceanu, I. [Institute for Physics and Nuclear Engineering (Romania); Cardella, G. [INFN, Sezione di Catania (Italy); Cavallaro, S. [INFN Laboratori Nazionali del Sud (Italy); Chatterjee, M. B. [Saha Institute of Nuclear Physics (India); Filippo, E. De [INFN, Sezione di Catania (Italy); Di Pietro, A.; Figuera, P. [INFN Laboratori Nazionali del Sud (Italy); Giuliani, G.; Geraci, E.; Grassi, L. [Dipartimento di Fisica e Astronomia Universita di Catania (Italy); Grzeszczuk, A. [University of Silesia, Institute of Physics (Poland); Han, J. [INFN Laboratori Nazionali del Sud (Italy); La Guidara, E. [INFN, Sezione di Catania (Italy); Lanzalone, G. [INFN Laboratori Nazionali del Sud (Italy); and others

    2011-11-15

    Isospin dependence of dynamical and thermodynamical properties observed in reactions {sup 40}Ca+ {sup 40,48}Ca and {sup 40}Ca + {sup 46}Ti at 25 MeV/nucleon has been studied. We used the CHIMERA multi-detector array. Strong isospin effects are seen in the isotopic distributions of light nuclei and in the competition between different reaction mechanisms in semi-central collisions. We will show also preliminary results obtained in nuclear collision {sup 48}Ca + {sup 48}Ca at 25MeV/nucleon, having very high N/Z value in the entrance channel (N/Z = 1.4). The enhancement of evaporation residue production confirms the strong role played by the N/Z degree of freedom in nuclear dynamics.

  9. Confirmed results of the 248Cm(48Ca,4n)292116 experiment

    International Nuclear Information System (INIS)

    Patin, J B; Moody, K J; Stoyer, M A; Wild, J F; Shaughnessy, D A; Stoyer, N J

    2003-01-01

    The results of a detailed analysis performed on the data obtained in the 248 Cm( 48 Ca,4n) 292 116 reaction is presented. This analysis is independent of the original data analysis performed in Dubna in which three separate decay chains were found. Each decay chain began with an evaporation residue followed by three α decays and ended in a spontaneous fission event, all correlated in time and position. The analysis presented confirms that the three events are present in the data. A summary of the three events will be given as well as a description of the analysis performed

  10. Polarization fatigue resistance of Ca-doped Pb(Zr0.52Ti0.48)O3 thin films prepared by the sol-gel method

    International Nuclear Information System (INIS)

    Wei, T.; Wang, Y.; Zhu, C.; Dong, X.W.; Xia, Y.D.; Zhu, J.S.; Liu, J.-M.

    2008-01-01

    The ferroelectric and polarization fatigue characteristics of Pb 1-x Ca x (Zr 0.52 Ti 0.48 )O 3 (PCZT) thin films prepared using the sol-gel method were studied. The Ca-doping slightly suppresses the ferroelectricity of Pb(Zr 0.52 Ti 0.48 )O 3 (PZT) because of the quantum paraelectric behavior of CaTiO 3 . Compared with PZT thin films, the PCZT (x=0.2) thin films show enhanced fatigue resistance at room temperature, further emphasized by the almost fatigue-free behavior at 100 K. The temperature-dependent dc-conductivity suggests a decrease of the oxygen vacancy density by almost 20 times and a slightly declined activation energy U for oxygen vacancies, upon increasing of the Ca-doping content from 0.0 to 0.2. It is argued that the improved fatigue endurance is ascribed to the decreasing density of oxygen vacancies due to the Ca-doping, although the lowered activation energy of oxygen vacancies is unfavorable. (orig.)

  11. Search for superheavy elements in the bombardment of 248Cm with 48Ca

    International Nuclear Information System (INIS)

    Hulet, E.K.; Lougheed, R.W.; Wild, J.F.; Landrum, J.H.; Stevenson, P.C.; Ghiorso, A.; Nitschke, J.M.; Otto, R.J.; Morrissey, D.J.; Baisden, P.A.; Gavin, B.F.; Lee, D.; Silva, R.J.; Fowler, M.M.; Seaborg, G.T.

    1977-01-01

    We have searched for superheavy elements 110 to 116 with half-lives between 10 4 and 10 8 s in fractions chemically separated after each of a series of bombardments of 248 Cm made with 267-MeV 48 Ca ions. After 6 months of α and spontaneous-fission counting, our results provide no persuasive evidence for the presence of super-heavy elements. The most plausible explanation for not finding the superheavy elements is that they have either short half-lives or very small formation cross sections

  12. Low-lying dipole response in the stable {sup 40,48}Ca nuclei within the second random-phase approximation

    Energy Technology Data Exchange (ETDEWEB)

    Gambacurta, D.; Grasso, M.; Catara, F. [GANIL,CEA/DSM-CNRS/IN2P3, Caen (France); Institut de Physique Nucleaire, Universite Paris-Sud, IN2P3-CNRS, F-91406 Orsay Cedex (France); Dipartimento di Fisica e Astronomia dell' Universita di and INFN Catania (Italy)

    2012-10-20

    The low-lying dipole strength distributions of {sup 40}CaCa and {sup 48}Ca, in the energy region between 5 and 10 MeV, are studied within the second random phase approximation (RPA) with Skyrme interaction. Standard RPA models do not usually predict any presence of strength in this energy region, while experimentally a significant amount of strength is found. The inclusion of the 2 particle -2 hole configurations allows to obtain a description in a rather good agreement with the experimental data. The properties of the most collective state are analyzed in terms of its 1 particle -1 hole nature and its transition densities.

  13. Recoil-alpha-fission and recoil-alpha-alpha-fission events observed in the reaction Ca-48 + Am-243

    NARCIS (Netherlands)

    Forsberg, U.; Rudolph, D.; Andersson, L. -L.; Nitto, A. Di; Düllmann, Ch E.; Gates, J. M.; Golubev, P.; Gregorich, K. E.; Gross, C. J.; Herzberg, R. -D.; Hessberger, F. P.; Khuyagbaatar, J.; Kratz, J. V.; Rykaczewski, K.; Sarmiento, L. G.; Schädel, M.; Yakushev, A.; Åberg, S.; Ackermann, D.; Block, M.; Brand, H.; Carlsson, B. G.; Cox, D.; Derkx, X.; Dobaczewski, J.; Eberhardt, K.; Even, J.; Fahlander, C.; Gerl, J.; Jäger, E.; Kindler, B.; Krier, J.; Kojouharov, I.; Kurz, N.; Lommel, B.; Mistry, A.; Mokry, C.; Nazarewicz, W.; Nitsche, H.; Omtvedt, J. P.; Papadakis, P.; Ragnarsson, I.; Runke, J.; Schaffner, H.; Schausten, B.; Shi, Y.; Thörle-Pospiech, P.; Torres, T.; Traut, T.; Trautmann, N.; Türler, A.; Ward, A.; Ward, D. E.; Wiehl, N.

    2016-01-01

    Products of the fusion-evaporation reaction Ca-48 + Am-243 were studied with the TASISpec set-up at the gas-filled separator TASCA at the GSI Helmholtzzentrum f\\"ur Schwerionenforschung. Amongst the detected thirty correlated alpha-decay chains associated with the production of element Z=115, two

  14. Probing the positron moderation process using high-intensity, highly polarized slow-positron beams

    Science.gov (United States)

    Van House, J.; Zitzewitz, P. W.

    1984-01-01

    A highly polarized (P = 0.48 + or - 0.02) intense (500,000/sec) beam of 'slow' (Delta E = about 2 eV) positrons (e+) is generated, and it is shown that it is possible to achieve polarization as high as P = 0.69 + or - 0.04 with reduced intensity. The measured polarization of the slow e+ emitted by five different positron moderators showed no dependence on the moderator atomic number (Z). It is concluded that only source positrons with final kinetic energy below 17 keV contribute to the slow-e+ beam, in disagreement with recent yield functions derived from low-energy measurements. Measurements of polarization and yield with absorbers of different Z between the source and moderator show the effects of the energy and angular distributions of the source positrons on P. The depolarization of fast e+ transmitted through high-Z absorbers has been measured. Applications of polarized slow-e+ beams are discussed.

  15. Coulomb displacement energy of the f sub(7/2) state of the 48Ca

    International Nuclear Information System (INIS)

    Sato, Hiroshi.

    1979-11-01

    The Coulomb displacement energy of the T = 4, J = 0 state of the 48 Ca is analyzed. Modifying a previous method of the calculation of the core polarization correction, it is found that the charge symmetry breaking force, which is introduced previously so as to help explain the Nolen-Schiffer anomaly of the T = 1/2 system, is also needed in this system, while there still exists an ambituity in the type of the force. (author)

  16. Post Thawing Sperm Quality and Ca+2 Intensity Characters of Local Goat Sperm After Freezing by Simple Method Using Deep Freezing

    Directory of Open Access Journals (Sweden)

    Gatot Ciptadi

    2018-02-01

    Full Text Available The objective of this research was to determine the effect of the simple modified freezing method, 1°C/minute freezing rate with different diluter ration on a post-thawing quality of local goat sperm namely Peranakan Etawah (PE. This work is aimed to study the quality of post-thawing sperm and to characterize the calcium intensity profile of both fresh and post thawing goat sperm. The method used is the experimental design of a laboratory. Freezing semen was performed in 2 main temperatures of -45°C then -196°C respectively using Mr. Frosty (® System. Early Sperm characters of Ca+2 intensity was performed by Confocal Laser Scanning Microscope (CLSM through Fluo-3 staining and Ca++ intensity was analysis descriptively. The result showed that post-thawing qualities are considered as good as standard qualities, at least, more than 40% based on Indonesian National Standard (SNI, 2014. The different level diluents commercial of Andromeda used were influenced highly significant (P<0.01. The best diluents ration is 1:4 (v/v for final sperms stocked at -196°C. However freezing sperm conserved in -196°C is better than in -45°C. Meanwhile, the sperm characters of two condition showed the important variation of Ca+2 intensity, with the length of region measurement of 39.06±4.595 and 32.696±9.011 µm each.  It was concluded that the calcium intensity pattern was varied more and higher in fresh sperm than in freezing sperms. This simple modified method of a freezing system was considered as a feasible alternative method for goat semen in a reason for both for sperm post-thawing quality and practical purposes.

  17. Shape of 44Ar: Onset of deformation in neutron-rich nuclei near 48Ca

    International Nuclear Information System (INIS)

    Zielinska, M.; Goergen, A.; Clement, E.; Korten, W.; Dossat, C.; Ljungvall, J.; Obertelli, A.; Theisen, Ch.; Delaroche, J.-P.; Girod, M.; Buerger, A.; Catford, W.; Iwanicki, J.; Napiorkowski, P. J.; Srebrny, J.; Wrzosek, K.; Libert, J.; PiePtak, D.; Rodriguez-Guzman, R.; Sletten, G.

    2009-01-01

    The development of deformation and shape coexistence in the vicinity of doubly magic 48 Ca, related to the weakening of the N=28 shell closure, was addressed in a low-energy Coulomb excitation experiment using a radioactive 44 Ar beam from the SPIRAL facility at GANIL. The 2 1 + and 2 2 + states in 44 Ar were excited on 208 Pb and 109 Ag targets at two different beam energies. B(E2) values between all observed states and the spectroscopic quadrupole moment of the 2 1 + state were extracted from the differential Coulomb excitation cross sections, indicating a prolate shape of the 44 Ar nucleus and giving evidence of an onset of deformation already two protons and two neutrons away from doubly magic 48 Ca. New Hartree-Fock-Bogoliubov based configuration mixing calculations have been performed with the Gogny D1S interaction for 44 Ar and neighboring nuclei using two different approaches: the angular momentum projected generator coordinate method considering axial quadrupole deformations and a five-dimensional approach including the triaxial degree of freedom. The experimental values and new calculations are furthermore compared to shell-model calculations and to relativistic mean-field calculations. The new results give insight into the weakening of the N=28 shell closure and the development of deformation in this neutron-rich region of the nuclear chart.

  18. High energy electron beams characterization using CaSO{sub 4}:Dy+PTFE Phosphors for clinical therapy applications

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, T., E-mail: trivera@ipn.mx [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada-Legaria, IPN. Av. Legaria 694, Col. Irrigacion. 11500 Mexico DF (Mexico); Espinoza, A.; Von, S.M. [Centro Estatal de Cancerologia de los Servicios de Salud de Nayarit, Enfermeria S/n, Fracc, Fray Junipero Serra, 63169 Tepic Nay (Mexico); Alvarez, R.; Jimenez, Y. [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada-Legaria, IPN. Av. Legaria 694, Col. Irrigacion. 11500 Mexico DF (Mexico)

    2012-07-15

    In the present work high energy electron beam dosimetry from linear accelerator (LINACs) for clinical applications using dysprosium doped calcium sulfate embedded in polytetrafluorethylene (CaSO{sub 4}:Dy+PTFE) was studied. The irradiations were carried out using high electron beams (6 to 18 MeV) from a linear accelerator (LINAC) Varian, CLINAC 2300C/D, for clinical practice purpose. The electron irradiations were obtained using the water solid in order to guarantee electronic equilibrium conditions (EEC). Field shaping for electron beams was obtained with electron cones. Glow curve and other thermoluminescent characteristics of CaSO{sub 4}:Dy+PTFE were conducted under high electrons beams irradiations. The TL response of the pellets showed an intensity peak centered at around 215 Degree-Sign C. TL response of CaSO{sub 4}:Dy+PTFE as a function of high electron absorbed dose showed a linearity in a wide range. To obtain reproducibility characteristic, a set of pellets were exposed repeatedly for the same electron absorbed dose. The results obtained in this study can suggest the applicability of CaSO{sub 4}:Dy+PTFE pellets for high electron beam dosimetry, provided fading is correctly accounted for. - Highlights: Black-Right-Pointing-Pointer Developing of CaSO{sub 4}:Dy to electron beams dosimetry. Black-Right-Pointing-Pointer Characterization of caSO{sub 4}:Dy to radiation safety in LINACs. Black-Right-Pointing-Pointer TL characteristics of CaSO{sub 4}:Dy for electron beams quality control.

  19. Study of the role of complete fusion in the reaction of 48Ca and 56Fe with cerium and terbium

    International Nuclear Information System (INIS)

    Morrissey, D.J.

    1978-05-01

    48 Ca and 56 Fe beams from the Super HILAC accelerator were used to irradiate thick metal foils of cerium and terbium. Product gamma ray activities were detected offline and individual products were identified by half-life, gamma ray energy and gamma ray abundances. The production cross sections were iteratively fit to charge and mass dispersions to allow correction for parent decay and calculation of mass yields. From the mass yield curves contributions from quasielastic transfer, deep inelastic transfer and complete fusion reaction mechanisms were interred. Complete fusion was made up on contributions from both evaporation residue and fusion-fission products for the 48 Ca induced reactions. However, only fusion-fission products were detected in the 56 Fe induced reactions. Critical angular momenta for fusion were found to be 82 +- 8 h for 48 Ca + 159 Tb and 34 +- 5 h for 56 Fe + 140 Ce, which can be compared with 53 +- 8 h for 12 C + 197 Au (Natowitz, 1970) and 86 +- 5 h for 40 Ar + 165 Ho (Hanappe, 1973). All of these reactions lead to essentially the same compound nucleus and seem to show the dramatic decline in complete fusion for heavy ions larger than 40 Ar. The prediction of this decline was found to be beyond the model calculations of Bass and the critical distance approach of Glas and Mosel

  20. Isospin diffusion in binary collisions of 32S+Ca,4840 and 32S+48Ti at 17.7 MeV/nucleon

    Science.gov (United States)

    Piantelli, S.; Valdré, S.; Barlini, S.; Casini, G.; Colonna, M.; Baiocco, G.; Bini, M.; Bruno, M.; Camaiani, A.; Carboni, S.; Cicerchia, M.; Cinausero, M.; D'Agostino, M.; Degerlier, M.; Fabris, D.; Gelli, N.; Gramegna, F.; Gruyer, D.; Kravchuk, V. L.; Mabiala, J.; Marchi, T.; Morelli, L.; Olmi, A.; Ottanelli, P.; Pasquali, G.; Pastore, G.

    2017-09-01

    The systems 32S+Ca,4840 and 32S+48Ti at 17.7 MeV/nucleon were investigated with the setup general array for fragment identification and for emitted light particles in dissipative collisions (GARFIELD) plus ring counter (RCo) at Laboratori Nazionali di Legnaro (LNL) of Istituto Nazionale di Fisica Nucleare (INFN). Fusion evaporation (FE), fusion fission (FF), and deep inelastic (DIC) events were identified, also through the comparison with the prediction of a transport model (stochastic mean field, SMF), coupled to GEMINI++ as an afterburner. This work mainly deals with the study of isospin transport phenomena in DIC events. In particular, the isospin diffusion is highlighted by comparing the average isotopic content of the quasiprojectile (QP) remnants observed when the target is the N =Z nucleus 40Ca and when it is the neutron-rich 48Ca. Also, the d /p and t /p ratios for particles forward emitted with respect to the QP were found to increase with increasing N /Z of the target.

  1. Contraction-induced changes in skeletal muscle Na(+), K(+) pump mRNA expression - importance of exercise intensity and Ca(2+)-mediated signalling

    DEFF Research Database (Denmark)

    Nordsborg, Nikolai Baastrup; Kusuhara, K; Hellsten, Ylva

    2010-01-01

    Abstract Aim: To investigate if exercise intensity and Ca(2+) signalling regulate Na(+), K(+) pump mRNA expression in skeletal muscle. Methods: The importance of exercise intensity was evaluated by having trained and untrained humans perform intense intermittent and prolonged exercise. The import...

  2. Water-bearing, high-pressure Ca-silicates

    Science.gov (United States)

    Németh, Péter; Leinenweber, Kurt; Ohfuji, Hiroaki; Groy, Thomas; Domanik, Kenneth J.; Kovács, István J.; Kovács, Judit S.; Buseck, Peter R.

    2017-07-01

    Water-bearing minerals provide fundamental knowledge regarding the water budget of the mantle and are geophysically significant through their influence on the rheological and seismic properties of Earth's interior. Here we investigate the CaO-SiO2-H2O system at 17 GPa and 1773 K, corresponding to mantle transition-zone condition, report new high-pressure (HP) water-bearing Ca-silicates and reveal the structural complexity of these phases. We document the HP polymorph of hartrurite (Ca3SiO5), post-hartrurite, which is tetragonal with space group P4/ncc, a = 6.820 (5), c = 10.243 (8) Å, V = 476.4 (8) Å3, and Z = 4, and is isostructural with Sr3SiO5. Post-hartrurite occurs in hydrous and anhydrous forms and coexists with larnite (Ca2SiO4), which we find also has a hydrous counterpart. Si is 4-coordinated in both post-hartrurite and larnite. In their hydrous forms, H substitutes for Si (4H for each Si; hydrogrossular substitution). Fourier transform infrared (FTIR) spectroscopy shows broad hydroxyl absorption bands at ∼3550 cm-1 and at 3500-3550 cm-1 for hydrous post-hartrurite and hydrous larnite, respectively. Hydrous post-hartrurite has a defect composition of Ca2.663Si0.826O5H1.370 (5.84 weight % H2O) according to electron-probe microanalysis (EPMA), and the Si deficiency relative to Ca is also observed in the single-crystal data. Hydrous larnite has average composition of Ca1.924Si0.851O4H0.748 (4.06 weight % H2O) according to EPMA, and it is in agreement with the Si occupancy obtained using X-ray data collected on a single crystal. Superlattice reflections occur in electron-diffraction patterns of the hydrous larnite and could indicate crystallographic ordering of the hydroxyl groups and their associated cation defects. Although textural and EPMA-based compositional evidence suggests that hydrous perovskite may occur in high-Ca-containing (or low silica-activity) systems, the FTIR measurement does not show a well-defined hydroxyl absorption band for this

  3. High temperature hydrogenation of CaC6

    International Nuclear Information System (INIS)

    Srinivas, G.; Howard, C.A.; Skipper, N.T.; Bennington, S.M.; Ellerby, M.

    2009-01-01

    The structure and superconducting properties of high temperature hydrogenated calcium-graphite intercalation compound, CaC 6 have been investigated using room temperature X-ray diffraction, and temperature and field dependence of magnetisation. It is found that the hydrogenation can only decompose the CaC 6 phase, and generate a mixture of CaH 2 and graphite as the final compound. The hydrogenation of CaC 6 also reveals a degradation of its superconducting properties. The experimental results are discussed in detail and it is found that the formation of stable CaH 2 and deintercalation are the main source for observed phase separation and suppression in superconductivity.

  4. High-intensity laser physics

    International Nuclear Information System (INIS)

    Mohideen, U.

    1993-01-01

    This thesis is a study of the effect of high intensity lasers on atoms, free electrons and the generation of X-rays from solid density plasmas. The laser produced 50 milli Joule 180 femto sec pulses at 5 Hz. This translates to a maximum intensity of 5 x 10 18 W/cm 2 . At such high fields the AC stark shifts of atoms placed at the focus is much greater than the ionization energy. The characteristics of multiphoton ionization of atoms in intense laser fields was studied by angle resolved photoelectron spectroscopy. Free electrons placed in high intensity laser fields lead to harmonic generation. This phenomenon of Nonlinear Compton Scattering was theoretically investigated. Also, when these high intensity pulses are focused on solids a hot plasma is created. This plasma is a bright source of a short X-ray pulse. The pulse-width of X-rays from these solid density plasmas was measured by time-resolved X-ray spectroscopy

  5. Coherent and incoherent giant dipole resonance γ-ray emission induced by heavy ion collisions: Study of the 40Ca+48Ca system by means of the constrained molecular dynamics model

    International Nuclear Information System (INIS)

    Papa, Massimo; Cardella, Giuseppe; Bonanno, Antonio; Pappalardo, Giuseppe; Rizzo, Francesca; Amorini, Francesca; Bonasera, Aldo; Di Pietro, Alessia; Figuera, Pier Paolo; Tudisco, Salvatore; Maruyama, Toshiki

    2003-01-01

    Coherent and incoherent dipolar γ-ray emission is studied in a fully dynamical approach by means of the constrained molecular dynamics model. The study is focused on the system 40 Ca+ 48 Ca for which recently experimental data have been collected at 25 MeV/nucleon. The approach allows us to explain the experimental results in a self-consistent way without using statistical or hybrid models. Moreover, calculations performed at higher energy show interesting correlations between the fragment formation process, the degree of collectivity, and the coherence degree of the γ-ray emission process

  6. First results on the 32S+40, 48Ca reactions at 17.7A MeV studied with GARFIELD setup at LNL

    Science.gov (United States)

    Piantelli, S.; Valdré, S.; Barlini, S.; Casini, G.; Colonna, M.; Baiocco, G.; Bini, M.; Bruno, M.; Camaiani, A.; Cicerchia, M.; Cinausero, M.; D'Agostino, M.; Degerlier, M.; Fabris, D.; Gramegna, F.; Kravchuck, V. L.; Mabiala, J.; Marchi, T.; Morelli, L.; Olmi, A.; Ottanelli, P.; Pasquali, G.; Pastore, G.

    2017-11-01

    The ^{32} S+ ^{40,48} Ca systems at 17A MeV have been characterized both for fusion and for peripheral events thanks to the GARFIELD setup, which covers a wide angular range and has high granularity; moreover, isotopic identification for forward emitted ions up to Z around 15 is obtained. The main evidences reported here concern pre-equilibrium emission, which was put into evidence in fusion-evaporation events, and isospin diffusion observed studying the average N/ Z of the Quasi-Projectile as a function of the target isospin.

  7. The synthesis of superheavy nuclei in the 48Ca + 244Pu reaction

    International Nuclear Information System (INIS)

    Oganesyan, Yu.Ts.; Utenkov, V.K.; Lobanov, Yu.V.

    1999-01-01

    In the bombardment of a 244 Pu target with 48 Ca ions, we observed a decay sequence consisting of an implanted heavy atom, three subsequent α-decays, and a spontaneous fission, all correlated in time and position. The measured α-energies and corresponding time intervals were: E α = 9.71 MeV (Δt = 30.4 s), 8.67 MeV (Δt = 15.4 min) and 8.83 MeV (Δt = 1.6 min); for the spontaneous fission (Δt = 16.5 min) the total deposited energy was approximately 190 MeV. The large alpha-particle energies together with the long decay times and spontaneous fission terminating the chain offer evidence of the decay of nuclei with high atomic numbers. This decay chain is a good candidate for originating from the α-decay of the parent nucleus 289 114, produced in the 3n-evaporation channel with a cross section of about 1 pb. The significant increase in the lifetimes of the new Z = 112 and 110 daughters of the Z = 114 nuclide (by a factor of ∼ 10 6 ) with respect to the known heaviest isotopes of elements 112 and 110 can be considered as a direct proof of the existence of the 'island of stability' of superheavy elements

  8. Ca-48 metabolism studies

    International Nuclear Information System (INIS)

    Van der Merwe, D.G.

    1987-03-01

    Calcium metabolism has been studied in depth physiologically and is a relatively well-understood element in biochemistry and medicine. There is still only restricted knowledge of the metabolic fate of calcium in normal and abnormal paediatric subjects. The latter is partially owing to inadequate techniques for tracing and modelling calcium pathways in children. The advent of radioactive tracers has unquestionably enhanced medical research and improved the quality of many metabolic studies. The present study was aimed at the development, promotion and justification of a new tracer technique using the stable isotope, calcium-48. The obvious advantages of such a technique are its harmlessness tothe subject, its applicability to both short- and long-term studies as well as its usefulness to the study for which it was originally motivated, viz research defining the actual relationship between a calcium-deficient diet and the occurrence of rickets in rural Black children in South Africa. Exploratory instrumental analyses were performed specifically with serum samples. This proved successful enough to develop a less specific pre-concentration technique which improved the sensitivity and reduces the cost of doing calcium-48 metabolism studies. The results of a simple metabolic study are presented whereby the scope of the technique is demonstrated in a real situation. The possibilities and limitations of double-isotope metabolic studies are discussed, particularly with regard to strontium as the second tracer

  9. Quasi-elastic scattering of electrons from 40Ca at high momentum transfer

    International Nuclear Information System (INIS)

    Yates, T.C.

    1992-01-01

    Previous quasi-elastic electron scattering experiments have yielded seemingly inconsistent results when the integrated longitudinal strength is compared to calculations using the relativistic fermi gas model. Measurements made at Saclay on 12 C, 40 Ca, 48 Ca, 56 Fe, and 208 Pb indicated a smaller integrated longitudinal strength than expected on the basis of the relativistic fermi gas model. However, 238 U data taken at Bates showed nearly the full expected longitudinal strength at a momentum transfer of 550 MeV/c. This is one of the outstanding discrepancies in nuclear physics. Earlier experiments were hampered in that high momentum transfer could not be obtained at forward angles where the longtudinal strength is a large fraction of the total strength. The present experiment was designed to take advantage of the higher energy capability (greater than 800 MeV) at Bates recirculated linac in order to obtain momentum transfers greater than 600 MeV/c at a scattering angle of 45.5 degrees. Under these conditions the longitudinal strength is 40-75% of the total quasi-elastic strength

  10. Muscular soreness following prolonged intermittent high-intensity shuttle running.

    Science.gov (United States)

    Thompson, D; Nicholas, C W; Williams, C

    1999-05-01

    The aim of this study was to examine the impact of prolonged intermittent high-intensity shuttle running on soreness and markers of muscle damage. Sixteen males took part in the study, half of whom were assigned to a running group and half to a resting control group. The exercise protocol involved 90 min of intermittent shuttle running and walking (Loughborough Intermittent Shuttle Test: LIST), reflecting the activity pattern found in multiple-sprint sports such as soccer. Immediately after exercise, there was a significant increase (P < 0.05) in serum activities of creatine kinase and aspartate aminotransferase, and values remained above baseline for 48 h (P < 0.05). Median peak activities of creatine kinase and aspartate aminotransferase occurred 24 h post-exercise and were 774 and 43 U x l(-1), respectively. The intensity of general muscle soreness, and in the specific muscles investigated, was greater than baseline for 72 h after the shuttle test (P < 0.05), peaking 24-48 h post-exercise (P < 0.05). Muscle soreness was not correlated with either creatine kinase or aspartate aminotransferase activity. Soreness was most frequently reported in the hamstrings. Neither soreness nor serum enzyme activity changed in the controls over the 4 day observation period. It appears that unaccustomed performance of prolonged intermittent shuttle running produces a significant increase in both soreness and markers of muscle damage.

  11. High intensity metallic ion beam from an ecr ion source using the Mivoc method

    International Nuclear Information System (INIS)

    Barue, C.; Canet, C.; Dupuis, M.; Flambard, J.L.; Leherissier, P.; Lemagnen, F.; Jaffres, P.A.

    2000-01-01

    The MIVOC method has been successfully used at GANIL to produce a high intensity nickel beam with the ECR4 ion source: 20 μA 58 Ni 11+ at 24 kV extraction voltage. This beam has been maintained for 8 days and accelerated up to 74.5 MeV/u by our cyclotrons with a mean intensity of 0.13 pμA on target. This high intensity, required for experiment, led to the discovery of the doubly magic 48 Ni isotope. Experimental setup, handling and off-line preparation using a residual gas analyzer are described in this report. The ion source behavior, performances and limitations are presented in the case of nickel and iron. The ionization efficiencies have been measured and compared to the oven method usually used at GANIL. (author)

  12. Thermoluminescent characteristics of CaSO{sub 4}:Dy+PTFE irradiated with high energy electron beams; Caracteristicas termoluminiscentes del CaSO{sub 4}:Dy+PTFE irradiado con haces de electrones de alta energia

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, R.; Rivera, T.; Calderon, J. A.; Jimenez, Y. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Rodriguez, J. [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06726 Mexico D. F. (Mexico); Oviedo, O. [Centro Medico ABC, Sur 136 No. 116, Col. Las Americas, 01120 Mexico D. F. (Mexico); Azorin, J., E-mail: chagua@hotmail.com [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco 186, 09340 Mexico D. F. (Mexico)

    2011-10-15

    In the present work thermoluminescent response of dysprosium doped calcium sulfate embedded in polytetrafluorethylene (CaSO{sub 4}:Dy+PTFE) under high electron beam irradiations from linear accelerator for clinical applications was investigated. The irradiations were carried out using high electron beams (6 to 18 MeV) from a linear accelerator Varian, C linac 2300C/D, for clinical practice purpose. The electron irradiations were obtained by using the water solid in order to guarantee electronic equilibrium conditions. Field shaping for electron beams was obtained with electron cones. Glow curve and other thermoluminescent characteristics of CaSO{sub 4}:Dy+PTFE were conducted under high electron beams irradiations. The thermoluminescent response of the pellets showed and intensity peak centered at around 235 C. Thermoluminescent response of CaSO{sub 4}:Dy+PTFE as a function of high electron absorbed dose showed a linearity in a wide range. To obtain reproducibility characteristic, a set of pellets were exposed repeatedly for the same electron absorbed dose. The results obtained in this study can suggest the applicability of CaSO{sub 4}:Dy+PTFE pellets for high electron beam dosimetry, provided fading is correctly accounted for. (Author)

  13. High-pressure densified solid solutions of alkaline earth hexaborides (Ca/Sr, Ca/Ba, Sr/Ba) and their high-temperature thermoelectric properties

    International Nuclear Information System (INIS)

    Gürsoy, M.; Takeda, M.; Albert, B.

    2015-01-01

    Solid solutions of alkaline earth hexaborides were synthesized and densified by spark plasma sintering at 100 MPa. The high-temperature thermoelectric properties (Seebeck coefficients, electrical and thermal diffusivities, heat capacities) were measured between room temperature and 1073 K. CaB 6 , SrB 6 , BaB 6 and the ternary hexaborides Ca x Sr 1−x B 6 , Ca x Ba 1−x B 6 , Sr x Ba 1−x B 6 (x = 0.25, 0.5, 0.75) are n-type conducting compounds over the whole compositional and thermal ranges. The values of the figure of merit ZT for CaB 6 (ca. 0.3 at 1073 K) were found to be significantly increased compared to earlier investigations which is attributed to the densification process. - Highlights: • Solid solutions of alkaline earth hexaborides were synthesized. • High-temperature thermoelectric properties of mixed calcium borides are excellent. • Spark plasma source densification results in high ZT values. • Borides are rare-earth free and refractory materials

  14. High intensity circular proton accelerators

    International Nuclear Information System (INIS)

    Craddock, M.K.

    1987-12-01

    Circular machines suitable for the acceleration of high intensity proton beams include cyclotrons, FFAG accelerators, and strong-focusing synchrotrons. This paper discusses considerations affecting the design of such machines for high intensity, especially space charge effects and the role of beam brightness in multistage accelerators. Current plans for building a new generation of high intensity 'kaon factories' are reviewed. 47 refs

  15. Study on the isospin equilibration phenomenon in nuclear reactions 40Ca + 40Ca , 40Ca + 46Ti , 40Ca + 48Ca , 48Ca + 48Ca at 25 MeV/nucleon by using the CHIMERA multidetector

    Science.gov (United States)

    Martorana, N. S.; Auditore, L.; Berceanu, I.; Cardella, G.; Chatterjee, M. B.; De Luca, S.; De Filippo, E.; Dell'Aquila, D.; Gnoffo, B.; Lanzalone, G.; Lombardo, I.; Maiolino, C.; Norella, S.; Pagano, A.; Pagano, E. V.; Papa, M.; Pirrone, S.; Politi, G.; Porto, F.; Quattrocchi, L.; Rizzo, F.; Russotto, P.; Trifirò, A.; Trimarchi, M.; Verde, G.; Vigilante, M.

    2017-11-01

    We report on the results obtained by studying nuclear reactions between isotopes of Ca and Ti at 25 MeV/nucleon. We used the multidetector CHIMERA to detect charged reaction products. In particular, we studied two main effects: the isospin diffusion and the isospin drift. In order to study these processes we performed a moving-source analysis on kinetic energy spectra of the isobar nuclei ^{3H} and ^{3He} . This method allows to isolate the emission from the typical sources produced in reactions at Fermi energy: projectile like fragment (PLF), target like fragment (TLF), and mid-velocity (MV) emission. The obtained results are compared to previous experimental investigations and to simulations obtained with CoMD-II model.

  16. 6/sup +/ isomer state in /sup 46/Ca

    Energy Technology Data Exchange (ETDEWEB)

    Bizzeti, P G; Maurenzig, P R; Poggi, G [Florence Univ. (Italy). Istituto di Fisica; Lo Bianco, G [Milan Univ. (Italy). Istituto di Fisica

    1975-01-11

    The decay of the expected isomer, obtained from the reaction /sup 48/Ca(p,p2n)/sup 46/Ca, has been observed as a delayed activity after bombardment of a 97.2% enriched /sup 48/CaC0/sub 3/ target with 35 MeV protons. The experimental apparatus used at AUF cyclotron of Milan is described. Data are reported and discussed.

  17. Does moderate-to-high intensity Nordic walking improve functional capacity and pain in fibromyalgia? A prospective randomized controlled trial

    OpenAIRE

    Mannerkorpi, Kaisa; Nordeman, Lena; Cider, ?sa; Jonsson, Gunilla

    2010-01-01

    Introduction The objective of this study was to investigate the effects of moderate-to-high intensity Nordic walking (NW) on functional capacity and pain in fibromyalgia (FM). Methods A total of 67 women with FM were recruited to the study and randomized either to moderate-to-high intensity Nordic Walking (n = 34, age 48 ? 7.8 years) or to a control group engaging in supervised low-intensity walking (LIW, n = 33, age 50 ? 7.6 years). Primary outcomes were the six-minute walk test (6MWT) and t...

  18. High level of CA 125 due to large endometrioma.

    Science.gov (United States)

    Phupong, Vorapong; Chen, Orawan; Ultchaswadi, Pornthip

    2004-09-01

    CA 125 is a tumor-associated antigen. Its high levels are usually associated with ovarian malignancies, whereas smaller increases in the levels were associated with benign gynecologic conditions. The authors report a high level of CA 125 in a case of large ovarian endometrioma. A 45-year-old nulliparous Thai woman, presented with an increase of her abdominal girth for 7 months. Transabdominal ultrasonogram demonstrated a large ovarian cyst and multiple small leiomyoma uteri, and serum CA 125 level was 1,006 U/ml. The preoperative diagnosis was ovarian cancer with leiomyoma uteri. Exploratory laparotomy was performed. There were a large right ovarian endometrioma, small left ovarian endometrioma and multiple small leiomyoma. Total abdominal hysterectomy and bilateral salpingo-oophorectomy was performed and histopathology confirmed the diagnosis of endometrioma and leiomyoma. The serum CA 125 level declined to non-detectable at the 4th week. She was well at discharge and throughout her 4th week follow-up period Although a very high level of CA 125 is associated with a malignant process, it can also be found in benign conditions such as a large endometrioma. The case emphasizes the association of high levels of CA 125 with benign gynecologic conditions.

  19. Fusion of the positive Q-value system 36S+48Ca well below the Coulomb barrier

    International Nuclear Information System (INIS)

    Stefanini, A. M.; Silvestri, R.; Corradi, L.; Fioretto, E.; Guiot, B.; Montagnoli, G.; Beghini, S.; Mason, P.; Scarlassara, F.; Courtin, S.; Haas, F.; Lebhertz, D.; Marginean, N.; Sagaidak, R. N.; Szilner, S.

    2008-01-01

    The fusion excitation function of 36 S+ 48 Ca has been measured from well above the barrier down to very small cross sections at sub-barrier energies. A steady decrease of the fusion cross sections is observed below the barrier with no pronounced change of slope. The logarithmic derivative saturates and does not reach the value expected for a constant astrophysical S-factor. The S-factor does not show any maximum in the measured energy range. Coupled-channels calculations using a Woods-Saxon potential have been performed

  20. Ultra-high resistive and anisotropic CoPd-CaF2 nanogranular soft magnetic films prepared by tandem-sputtering deposition

    Science.gov (United States)

    Naoe, Masayuki; Kobayashi, Nobukiyo; Ohnuma, Shigehiro; Iwasa, Tadayoshi; Arai, Ken-Ichi; Masumoto, Hiroshi

    2015-10-01

    Ultra-high resistive and anisotropic soft magnetic films for gigahertz applications are desirable to demonstrate the really practical films. Here we present a study of novel nanogranular films fabricated by tandem-sputtering deposition. Their electromagnetic properties and nanostructure have also been discussed. These films consisted of nanocrystallized CoPd alloy-granules and CaF2 matrix, and a specimen having a composition of (Co0.69Pd0.31)52-(Ca0.31F0.69)48 exhibited distinct in-plane uniaxial anisotropy after uniaxial field annealing with granule growth. Its complex permeability spectra have a ferromagnetic resonance frequency extending to the Super-High-Frequency band due to its higher anisotropy field, and its frequency response was quite well reproduced by a numerical calculation based on the Landau-Lifshitz-Gilbert equation. Furthermore, it was clarified that the CaF2-based nanogranular film exhibits a hundredfold higher electrical resistivity than conventional oxide or nitride-based films. Higher resistivity enables the film thickness to achieve a margin exceeding threefold against eddy current loss. The greater resistivity of nanogranular films is attributed to the wide energy bandgap and superior crystallinity of CaF2 matrix.

  1. Dependence of high order harmonics intensity on laser focal spot position in preformed plasma plumes

    International Nuclear Information System (INIS)

    Singhal, H.; Ganeev, R.; Naik, P. A.; Arora, V.; Chakravarty, U.; Gupta, P. D.

    2008-01-01

    The dependence of the high-order harmonic intensity on the laser focal spot position in laser produced plasma plumes is experimentally studied. High order harmonics up to the 59th order (λ∼13.5 nm) were generated by focusing 48 fs laser pulses from a Ti:sapphire laser system in silver plasma plume produced using 300 ps uncompressed laser radiation as the prepulse. The intensity of harmonics nearly vanished when the best focus was located in the plume center, whereas it peaked on either side with unequal intensity. The focal spot position corresponding to the peak harmonic intensity moved away from the plume center for higher order harmonics. The results are explained in terms of the variation of phase mismatch between the driving laser beam and harmonics radiation produced, relativistic drift of electrons, and defocusing effect due to radial ionization gradient in the plasma for different focal spot positions

  2. High intensity proton accelerator controls network upgrade

    International Nuclear Information System (INIS)

    Krempaska, R.; Bertrand, A.; Lendzian, F.; Lutz, H.

    2012-01-01

    The High Intensity Proton Accelerator (HIPA) control system network is spread through a vast area in PSI and it was grown historically in an unorganized way. The miscellaneous network hardware infrastructure and the lack of the documentation and components overview could no longer guarantee the reliability of the control system and the facility operation. Therefore, a new network, based on modern network topology, PSI standard hardware with monitoring and detailed documentation and overview was needed. The number of active components has been reduced from 25 to 9 Cisco Catalyst 24- or 48-port switches. They are the same type as other PSI switches, thus a replacement emergency stock is not an issue anymore. We would like to present how we successfully achieved this goal and the advantages of the clean and well documented network infrastructure. (authors)

  3. Compton scattering at high intensities

    Energy Technology Data Exchange (ETDEWEB)

    Heinzl, Thomas, E-mail: thomas.heinzl@plymouth.ac.u [University of Plymouth, School of Mathematics and Statistics, Drake Circus, Plymouth PL4 8AA (United Kingdom)

    2009-12-01

    High-intensity Compton scattering takes place when an electron beam is brought into collision with a high power laser. We briefly review the main intensity signatures using the formalism of strong-field quantum electrodynamics.

  4. Mass of 48K

    International Nuclear Information System (INIS)

    Weisser, D.C.; Zeller, A.F.; Ophel, T.R.; Hebbard, D.F.

    1978-08-01

    The mass excess of 48 K was measured to be -32.117 +or- .027 MeV using the 48 Ca( 7 Li, 7 Be) 48 K reaction at 52 MeV. The result is consistent with predictions and a previous less accurate measurement. There is evidence for an excited state in 48 K at 0.58 MeV

  5. Chemical Identification of Dubnium as a Decay Product of Element 115 Produced in the Reaction $\\rm {^{48}Ca}+{^{243}Am}$

    CERN Document Server

    Dmitriev, S N; Utyonkov, V K; Shishkin, S V; Eremin, A V; Lobanov, Yu V; Chepigin, V I; Sokol, E A; Tsyganov, Yu S; Vostokin, G K; Aksenov, N V; Hussonnois, M; Itkis, M G; Aggeler, H W; Schumann, D; Bruchertseifer, H; Eichler, R; Shaughnessy, D A; Wilk, P A; Kenneally, J M; Stoyer, M A; Wild, J F

    2004-01-01

    The results of an experiment designed to identify $^{268}$Db as the terminal isotope in the $\\alpha $-decay chain of element 115 produced via the ${\\rm {^{243}Am}}({\\rm {^{48}Ca}},3n){\\rm {^{288}115}}$ reaction are presented. The $^{243}$Am target was bombarded with a beam dose of $3.4\\cdot 10^{18}$ $^{48}$Ca projectiles at an energy of 247 MeV at the center of the target. The reaction products were collected in the surface layer of a copper catcher block, which was removed with a lathe and then dissolved in concentrated HNO$_{3}$. The group-5 elements were separated by sorption onto Dowex $50{\\times} 8$ cation-exchange resin with subsequent desorption using 1 M HF, which forms anionic fluoride complexes of group-5 elements. The eluent was evaporated onto a 0.4 $\\mu$m thick polyethylene foil that was placed between a pair of semiconductor detectors surrounded by $^{3}$He neutron counters for measurement of $\\alpha$ particles, fission fragments, and neutrons. In the course of the experiment, we observed 15 spo...

  6. Ca(2+)-calmodulin-dependent phosphorylation of islet secretory granule proteins

    International Nuclear Information System (INIS)

    Watkins, D.T.

    1991-01-01

    The effect of Ca2+ and calmodulin on phosphorylation of islet secretory granule proteins was studied. Secretory granules were incubated in a phosphorylation reaction mixture containing [32P]ATP and test reagents. The 32P-labeled proteins were resolved by sodium dodecyl sulfate-polyacrylamide gel electrophoresis, the 32P content was visualized by autoradiography, and the relative intensities of specific bands were quantitated. When the reaction mixture contained EGTA and no added Ca2+, 32P was incorporated into two proteins with molecular weights of 45,000 and 13,000. When 10(-4) M Ca2+ was added without EGTA, two additional proteins (58,000 and 48,000 Mr) were phosphorylated, and the 13,000-Mr protein was absent. The addition of 2.4 microM calmodulin markedly enhanced the phosphorylation of the 58,000- and 48,000-Mr proteins and resulted in the phosphorylation of a major protein whose molecular weight (64,000 Mr) is identical to that of one of the calmodulin binding proteins located on the granule surface. Calmodulin had no effect on phosphorylation in the absence of Ca2+ but was effective in the presence of calcium between 10 nM and 50 microM. Trifluoperazine and calmidazolium, calmodulin antagonists, produced a dose-dependent inhibition of the calmodulin effect. 12-O-tetradecanoylphorbol 13-acetate, a phorbol ester that activates protein kinase C, produced no increase in phosphorylation, and 1-(5-isoquinoline sulfonyl)-2-methyl piperazine dihydrochloride, an inhibitor of protein kinase C, had no effect. These results indicate that Ca(2+)-calmodulin-dependent protein kinases and endogenous substrates are present in islet secretory granules

  7. Superconductivity under high pressure in the binary compound CaLi2

    Science.gov (United States)

    Debessai, M.; Matsuoka, T.; Hamlin, J. J.; Gangopadhyay, A. K.; Schilling, J. S.; Shimizu, K.; Ohishi, Y.

    2008-12-01

    Feng predicted for CaLi2 highly anomalous properties with possible superconductivity under very high pressures, including for the hcp polymorph a significant lattice bifurcation at pressures above 47 GPa. More recently, however, Feng suggested that for pressures exceeding 20 GPa CaLi2 may dissociate into elemental Ca and Li. Here we present for hcp CaLi2 measurements of the electrical resistivity and ac susceptibility to low temperatures under pressures as high as 81 GPa. Pressure-induced superconductivity is observed in the pressure range of 11-81 GPa, with Tc reaching values as high as 13 K. X-ray diffraction studies to 54 GPa at 150 K reveal that hcp CaLi2 undergoes a structural phase transition above 23 GPa to orthorhombic but does not dissociate into elemental Ca and Li. In the hcp phase a fit of the equation of state with the Murnaghan equation yields the bulk modulus Bo=15(2)GPa and dBo/dP=3.2(6) .

  8. Nuclear response in an extended RPA formalism; an application to 48Ca

    International Nuclear Information System (INIS)

    Brand, M.G.E.; Allaart, K.; Dickhoff, W.H.

    1990-01-01

    An extension of the standard (1p1h) Random Phase Approximation (RPA) is derived, by considering the Feynman diagram expansion of the polarization propagator and the relationship between the self-energy and the particle-hole interaction that must be fulfilled in order to obey conservation laws. The resulting Extended RPA (ERPA) equations include the dynamic coupling of 1p1h states to 2p2h states, which leads to a fragmentation of single-particle and single-hole strength and screening of the interaction by the medium. The method has been applied to 48 Ca using a realistic G-matrix interaction based on meson-exchange. The results show an improved description of the response over the whole energy range up to 100 MeV. Remaining discrepancies point in the direction of further strength reduction due to short-range correlations as well as a stronger coupling to 2p2h states at low energy. (author)

  9. Synthesis and Photoluminescence Properties of Ca2Ga2SiO7:Eu(3+) Red Phosphors with an Intense (5)D0 → (7)F4 Transition.

    Science.gov (United States)

    Behrh, Gaganpreet Kaur; Gautier, Romain; Latouche, Camille; Jobic, Stéphane; Serier-Brault, Hélène

    2016-09-19

    Novel melilite-type Ca2Ga2SiO7:Eu(3+) red-emitting phosphors with different Eu(3+) contents were synthesized via high-temperature solid-state reaction. The crystal structure, optical absorption, and photoluminescence properties were investigated, while density functional theory calculations were performed on the host lattice. The excitation spectra indicate that phosphors can be effectively excited by near-UV light for a potential application in white-light-emitting diodes. Because of the abnormally high intensity emission at about 700 nm arising from the (5)D0 → (7)F4 transition of Eu(3+), the phosphors Ca2Ga2SiO7:Eu(3+) show a deep-red emission with chromaticity coordinates (0.639, 0.358).

  10. Ultra-high resistive and anisotropic CoPd–CaF{sub 2} nanogranular soft magnetic films prepared by tandem-sputtering deposition

    Energy Technology Data Exchange (ETDEWEB)

    Naoe, Masayuki, E-mail: naoe@denjiken.ne.jp [Research Institute for Electromagnetic Materials, 2-1-1 Yagiyama-Minami, Taihaku-ku, Sendai 982-0807 (Japan); Kobayashi, Nobukiyo [Research Institute for Electromagnetic Materials, 2-1-1 Yagiyama-Minami, Taihaku-ku, Sendai 982-0807 (Japan); Ohnuma, Shigehiro [Research Institute for Electromagnetic Materials, 2-1-1 Yagiyama-Minami, Taihaku-ku, Sendai 982-0807 (Japan); Frontier Research Institute for Interdisciplinary Sciences, Tohoku University, 6-3 Aramaki-aza-Aoba, Aoba-ku, Sendai 980-8578 (Japan); Iwasa, Tadayoshi; Arai, Ken-Ichi [Research Institute for Electromagnetic Materials, 2-1-1 Yagiyama-Minami, Taihaku-ku, Sendai 982-0807 (Japan); Masumoto, Hiroshi [Frontier Research Institute for Interdisciplinary Sciences, Tohoku University, 6-3 Aramaki-aza-Aoba, Aoba-ku, Sendai 980-8578 (Japan)

    2015-10-01

    Ultra-high resistive and anisotropic soft magnetic films for gigahertz applications are desirable to demonstrate the really practical films. Here we present a study of novel nanogranular films fabricated by tandem-sputtering deposition. Their electromagnetic properties and nanostructure have also been discussed. These films consisted of nanocrystallized CoPd alloy-granules and CaF{sub 2} matrix, and a specimen having a composition of (Co{sub 0.69}Pd{sub 0.31}){sub 52}–(Ca{sub 0.31}F{sub 0.69}){sub 48} exhibited distinct in-plane uniaxial anisotropy after uniaxial field annealing with granule growth. Its complex permeability spectra have a ferromagnetic resonance frequency extending to the Super-High-Frequency band due to its higher anisotropy field, and its frequency response was quite well reproduced by a numerical calculation based on the Landau–Lifshitz–Gilbert equation. Furthermore, it was clarified that the CaF{sub 2}-based nanogranular film exhibits a hundredfold higher electrical resistivity than conventional oxide or nitride-based films. Higher resistivity enables the film thickness to achieve a margin exceeding threefold against eddy current loss. The greater resistivity of nanogranular films is attributed to the wide energy bandgap and superior crystallinity of CaF{sub 2} matrix. - Highlights: • We fabricated high-resistive and anisotropic granular films by tandem-sputtering. • CaF{sub 2}-based films exhibit a hundredfold higher resistivity than conventional films. • Uniaxial field annealing improved the magnetic properties dramatically. • High uniaxial anisotropy extended ferromagnetic resonance frequency to 4 GHz. • Annealed samples can be regarded as a ferromagnetic homogenized material.

  11. NiF2/NaF:CaF2/Ca Solid-State High-Temperature Battery Cells

    Science.gov (United States)

    West, William; Whitacre, Jay; DelCastillo, Linda

    2009-01-01

    Experiments and theoretical study have demonstrated the promise of all-solid-state, high-temperature electrochemical battery cells based on NiF2 as the active cathode material, CaF2 doped with NaF as the electrolyte material, and Ca as the active anode material. These and other all-solid-state cells have been investigated in a continuing effort to develop batteries for instruments that must operate in environments much hotter than can be withstood by ordinary commercially available batteries. Batteries of this type are needed for exploration of Venus (where the mean surface temperature is about 450 C), and could be used on Earth for such applications as measuring physical and chemical conditions in geothermal wells and oil wells. All-solid-state high-temperature power cells are sought as alternatives to other high-temperature power cells based, variously, on molten anodes and cathodes or molten eutectic salt electrolytes. Among the all-solid-state predecessors of the present NiF2/NaF:CaF2/Ca cells are those described in "Solid-State High-Temperature Power Cells" (NPO-44396), NASA Tech Briefs, Vol. 32, No. 5 (May 2008), page 40. In those cells, the active cathode material is FeS2, the electrolyte material is a crystalline solid solution of equimolar amounts of Li3PO4 and LiSiO4, and the active anode material is Li contained within an alloy that remains solid in the intended high operational temperature range.

  12. High pressure and [Ca2+] produce an inverse modulation of synaptic input strength, network excitability and frequency response in the rat dentate gyrus

    Directory of Open Access Journals (Sweden)

    Thomas I Talpalar

    2016-09-01

    Full Text Available Hyperbaric environments induce the high pressure neurological syndrome (HPNS characterized by hyperexcitability of the central nervous system and memory impairment. Human divers and other animals experience the HPNS at pressures beyond 1.1 MPa. High pressure depresses synaptic transmission and alters its dynamics in various animal models. Medial perforant path (MPP synapses connecting the medial entorhinal cortex with the hippocampal formation are suppressed by 50% at 10.1MPa. Reduction of synaptic inputs is paradoxically associated with enhanced ability of dentate gyrus’ granule cells to generate spikes at high pressure. This mechanism allows MPP inputs to elicit standard granule cell outputs at 0.1 -25 Hz frequencies under hyperbaric conditions. An increased postsynaptic gain of MPP inputs probably allows diving animals to perform in hyperbaric environments, but makes them vulnerable to high intensity/frequency stimuli producing hyperexcitability. Increasing extracellular Ca2+ (Ca2+o partially reverted pressure-mediated depression of MPP inputs and increased MPP’s low-pass filter properties. We postulated that raising Ca2+o in addition to increase synaptic inputs may reduce network excitability in the dentate gyrus potentially improving its function and reducing sensitivity to high intensity and pathologic stimuli. For this matter, we activated the MPP with single and 50 Hz frequency stimuli that simulated physiologic and deleterious conditions, while assessing the granule cell’s output under various conditions of pressure and Ca2+o. Our results reveal that pressure and Ca2+o produce an inverse modulation on synaptic input strength and network excitability. These coincident phenomena suggest a potential general mechanism of networks that adjusts gain as an inverse function of synaptic inputs’ strength. Such mechanism may serve for adaptation to variable pressure and other physiological and pathological conditions and may explain the

  13. High Intensity Exercise in Multiple Sclerosis

    DEFF Research Database (Denmark)

    Wens, Inez; Dalgas, Ulrik; Vandenabeele, Frank

    2015-01-01

    Introduction Low-to-moderate intensity exercise improves muscle contractile properties and endurance capacity in multiple sclerosis (MS). The impact of high intensity exercise remains unknown. Methods Thirty-four MS patients were randomized into a sedentary control group (SED, n = 11) and 2...... exercise groups that performed 12 weeks of a high intensity interval (HITR, n = 12) or high intensity continuous cardiovascular training (HCTR, n = 11), both in combination with resistance training. M.vastus lateralis fiber cross sectional area (CSA) and proportion, knee-flexor/extensor strength, body...... composition, maximal endurance capacity and self-reported physical activity levels were assessed before and after 12 weeks. Results Compared to SED, 12 weeks of high intensity exercise increased mean fiber CSA (HITR: +21±7%, HCTR: +23±5%). Furthermore, fiber type I CSA increased in HCTR (+29±6%), whereas type...

  14. Successful control of 2 simultaneous outbreaks of OXA-48 carbapenemase-producing Enterobacteriaceae and multidrug-resistant Acinetobacter baumannii in an intensive care unit.

    Science.gov (United States)

    Robustillo-Rodela, A; Pérez-Blanco, V; Espinel Ruiz, M A; Ruiz Carrascoso, G; Figueira Iglesias, J C; Abad Martín, D

    2017-12-01

    This report describes a double outbreak of OXA-48-producing Enterobacteriaceae (OXA-48-PE) and multidrug-resistant Acinetobacter baumannii (MRAB) in an intensive care unit (ICU) and the effectiveness of measures implemented, including decontamination with vaporized hydrogen peroxide (VHP). Affected patients were isolated in a confined area and cared for by dedicated personnel. Four percent chlorhexidine soap was used for patient daily hygiene. All patients are subjected to contact precautions. An in-depth cleaning of the ICU was performed with a chlorine solution, followed by decontamination with VHP. Environmental samples were taken before and after the decontamination. From July-October 2015, 13 patients were colonized or infected by OXA-48-PE and 18 by MRAB in the ICU. The cumulative incidence of OXA-48-PE and MRAB was 3.48% and 4.81%, respectively. In the period after the intervention, they were 0.8% and 0%, respectively (P control of outbreaks caused by microorganisms of high environmental impact. The rapid effect after the VHP treatment suggests an influence of this measure in eradication. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  15. A new drift chamber TDC readout for the high intensity program of the NA48 experiment

    CERN Document Server

    Ramusino, A C; Cartiglia, N; Chiozzi, S; Clemencic, M; Damiani, C; Gianoli, A; Milano, L; Malaguti, R; Petrucci, F; Scarpa, M

    2004-01-01

    A new read-out for the drift chambers (DCH) (8192 channels) of the NA48 experiment at CERN has been developed and realized by the Ferrara and Torino INFN sites and has taken data during the 2002 run. The core of the system is a set of 32 VME-9U Time-to-Digital- Converter boards (NA48-TDC). The NA48-TDCs record the time of arrival of signals from the DCH and store them in 40 MHz pipelined ring memories pending the trigger supervisor's decision. Dual memories and data extraction resources allow independent and simultaneous processing of level-1 and level-2 trigger requests. Time measurements are performed by the TDC-F1 commercial ASICs, having an intrinsic time resolution of 120 ps and multi-hit capabilities. The NA48-TDC board features a maximum sustained rate of 500 kHz per channel.

  16. A new drift chamber TDC readout for the high intensity program of the NA48 experiment

    International Nuclear Information System (INIS)

    Arcidiacono, R.; Cartiglia, N.; Chiozzi, S.; Clemencic, M.; Cotta Ramusino, A.; Damiani, C.; Gianoli, A.; Milano, L.; Malaguti, R.; Petrucci, F.; Scarpa, M.

    2004-01-01

    A new read-out for the drift chambers (DCH) (8192 channels) of the NA48 experiment at CERN has been developed and realized by the Ferrara and Torino INFN sites and has taken data during the 2002 run. The core of the system is a set of 32 VME-9U Time-to-Digital-Converter boards (NA48-TDC). The NA48-TDCs record the time of arrival of signals from the DCH and store them in 40 MHz pipelined ring memories pending the trigger supervisor's decision. Dual memories and data extraction resources allow independent and simultaneous processing of level-1 and level-2 trigger requests. Time measurements are performed by the TDC-F1 commercial ASICs, having an intrinsic time resolution of 120 ps and multi-hit capabilities. The NA48-TDC board features a maximum sustained rate of 500 kHz per channel

  17. Soft spin-dipole resonances in 40Ca

    International Nuclear Information System (INIS)

    Stuhl, L; Krasznahorkay, A; Csatlós, M; Gulyás, J; Marketin, T; Litvinova, E; Adachi, T; Fujita, H; Hatanaka, K; Hirota, K; Ong, H J; Ishikawa, D; Matsubara, H; Algora, A; Estevez, E; Molina, F; Daeven, J; Guess, C; Meharchand, R; Fujita, Y

    2012-01-01

    High resolution experimental data has been obtained for the 40,42,44,48 Ca( 3 He,t)Sc charge exchange reaction at 420 MeV beam energy, which favors the spin-isospin excitations. The measured angular distributions were analyzed for each state separately, and the relative spin dipole strength has been extracted for the first time. The low-lying spin-dipole strength distribution in 40 Sc shows some interesting periodic gross feature. It resembles to a soft, damped multi-phonon vibrational band with hω= 1.8 MeV, which might be associated to pairing vibrations around 40 Ca.

  18. Highly expressed genes within hippocampal sector CA1: implications for the physiology of memory

    Directory of Open Access Journals (Sweden)

    Michael A. Meyer

    2014-06-01

    Full Text Available As the CA1 sector has been implicated to play a key role in memory formation, a dedicated search for highly expressed genes within this region was made from an on-line atlas of gene expression within the mouse brain (GENSAT. From a data base of 1013 genes, 16 were identified that had selective localization of gene expression within the CA1 region, and included Angpt2, ARHGEF6, CCK, Cntnap1, DRD3, EMP1, Epha2, Itm2b, Lrrtm2, Mdk, PNMT, Ppm1e, Ppp2r2d, RASGRP1, Slitrk5, and Sstr4. Of the 16 identified, the most selective and intense localization for both adult and post-natal day 7 was noted for ARHGEF6, which is known to be linked to non-syndromic mental retardation, and has also been localized to dendritic spines. Further research on the role played by ARHGEF6 in memory formation is strongly advocated.

  19. Highly Expressed Genes within Hippocampal Sector CA1: Implications for the Physiology of Memory.

    Science.gov (United States)

    Meyer, Michael A

    2014-04-22

    As the CA1 sector has been implicated to play a key role in memory formation, a dedicated search for highly expressed genes within this region was made from an on-line atlas of gene expression within the mouse brain (GENSAT). From a data base of 1013 genes, 16 were identified that had selective localization of gene expression within the CA1 region, and included Angpt2, ARHGEF6, CCK, Cntnap1, DRD3, EMP1, Epha2, Itm2b, Lrrtm2, Mdk, PNMT, Ppm1e, Ppp2r2d, RASGRP1, Slitrk5, and Sstr4. Of the 16 identified, the most selective and intense localization for both adult and post-natal day 7 was noted for ARHGEF6, which is known to be linked to non-syndromic mental retardation, and has also been localized to dendritic spines. Further research on the role played by ARHGEF6 in memory formation is strongly advocated.

  20. High-intensity interval training: Modulating interval duration in overweight/obese men.

    Science.gov (United States)

    Smith-Ryan, Abbie E; Melvin, Malia N; Wingfield, Hailee L

    2015-05-01

    High-intensity interval training (HIIT) is a time-efficient strategy shown to induce various cardiovascular and metabolic adaptations. Little is known about the optimal tolerable combination of intensity and volume necessary for adaptations, especially in clinical populations. In a randomized controlled pilot design, we evaluated the effects of two types of interval training protocols, varying in intensity and interval duration, on clinical outcomes in overweight/obese men. Twenty-five men [body mass index (BMI) > 25 kg · m(2)] completed baseline body composition measures: fat mass (FM), lean mass (LM) and percent body fat (%BF) and fasting blood glucose, lipids and insulin (IN). A graded exercise cycling test was completed for peak oxygen consumption (VO2peak) and power output (PO). Participants were randomly assigned to high-intensity short interval (1MIN-HIIT), high-intensity interval (2MIN-HIIT) or control groups. 1MIN-HIIT and 2MIN-HIIT completed 3 weeks of cycling interval training, 3 days/week, consisting of either 10 × 1 min bouts at 90% PO with 1 min rests (1MIN-HIIT) or 5 × 2 min bouts with 1 min rests at undulating intensities (80%-100%) (2MIN-HIIT). There were no significant training effects on FM (Δ1.06 ± 1.25 kg) or %BF (Δ1.13% ± 1.88%), compared to CON. Increases in LM were not significant but increased by 1.7 kg and 2.1 kg for 1MIN and 2MIN-HIIT groups, respectively. Increases in VO2peak were also not significant for 1MIN (3.4 ml·kg(-1) · min(-1)) or 2MIN groups (2.7 ml · kg(-1) · min(-1)). IN sensitivity (HOMA-IR) improved for both training groups (Δ-2.78 ± 3.48 units; p < 0.05) compared to CON. HIIT may be an effective short-term strategy to improve cardiorespiratory fitness and IN sensitivity in overweight males.

  1. CaSO4:DY,Mn: A new and highly sensitive thermoluminescence phosphor for versatile dosimetry

    Science.gov (United States)

    Bahl, Shaila; Lochab, S. P.; Kumar, Pratik

    2016-02-01

    With the advent of newer techniques for dose reduction coupled with the development of more sensitive detectors, the radiation doses in radiological medical investigation are decreasing. Nevertheless, keeping the tenet in mind that all radiation doses could entail risk, there is a need to develop more sensitive dosimeters capable of measuring low doses. This paper gives the account of the development of a new and sensitive phosphor CaSO4:Dy,Mn and its characterization. The standard production procedure based on the recrystallization method was used to prepare CaSO4:Dy,Mn. The Thermoluminescence (TL) studies were carried out by exposing it with gamma radiation (Cs-137) from 10 μGy to 100 Gy. The theoretical studies to determine the number of peaks and kinetic parameters related to the TL glow peaks in CaSO4:Dy,Mn was performed using the Computerized Glow Curve Deconvolution (CGCD) method. Experiments were performed to determine optimum concentration of the dopants Dysprosium (Dy) and Mangnese (Mn) in the host CaSO4 so that maximum sensitivity of the phosphor may be achieved. The optimum dopant concentration turned out to be 0.1 mol%. As there were two dopants Dy and Mn their relative ratio were varied in steps of 0.025 keeping the concentration of total dopant (Dy and Mn) 0.1 mol% always. The maximum TL intensity was seen in the CaSO4:Dy(0.025),Mn(0.075) combination. The TL sensitivity of this phosphor was found to be about 2 and 1.8 times higher than that of popular phosphor CaSO4:Dy and LiF:Mg,Cu,P (TLD-700H) respectively. This new phosphor CaSO4:Dy,Mn showed fading of 11% which is similar to that of the standard phosphor CaSO4:Dy. The paper concludes that the new, highly sensitive TL phosphor CaSO4:Dy,Mn has shown higher sensitivity and hence the potential to replace commonly used CaSO4:Dy.

  2. Comparison of affective responses during and after low volume high-intensity interval exercise, continuous moderate- and continuous high-intensity exercise in active, untrained, healthy males.

    Science.gov (United States)

    Niven, Ailsa; Thow, Jacqueline; Holroyd, Jack; Turner, Anthony P; Phillips, Shaun M

    2018-09-01

    This study compared affective responses to low volume high-intensity interval exercise (HIIE), moderate-intensity continuous exercise (MICE) and high-intensity continuous exercise (HICE). Twelve untrained males ([Formula: see text] 48.2 ± 6.7 ml·kg -1 ·min -1 ) completed MICE (30 min cycle at 85% of ventilatory threshold (VT)), HICE (cycle at 105% of VT matched with MICE for total work), and HIIE (10 x 6 s cycle sprints with 60 s recovery). Affective valence and perceived activation were measured before exercise, post warm-up, every 20% of exercise time, and 1, 5, 10, and 15 min post-exercise. Affective valence during exercise declined by 1.75 ± 2.42, 1.17 ± 1.99, and 0.42 ± 1.38 units in HICE, HIIE, and MICE, respectively, but was not statistically influenced by trial (P = 0.35), time (P = 0.06), or interaction effect (P = 0.08). Affective valence during HICE and HIIE was consistently less positive than MICE. Affective valence post-exercise was not statistically influenced by trial (P = 0.10) and at 5 min post-exercise exceeded end-exercise values (P = 0.048). Circumplex profiles showed no negative affect in any trial. Affective responses to low volume HIIE are similar to HICE but remain positive and rebound rapidly, suggesting it may be a potential alternative exercise prescription.

  3. Cordyceps militaris improves tolerance to high intensity exercise after acute and chronic supplementation

    Science.gov (United States)

    Hirsch, Katie R.; Smith-Ryan, Abbie E.; Roelofs, Erica J.; Trexler, Eric T.; Mock, Meredith G.

    2016-01-01

    To determine the effects of a mushroom blend containing cordyceps militaris on high intensity exercise after 1- and 3-weeks of supplementation. Twenty-eight individuals (Mean ± SD; Age=22.7 ± 4.1 yrs; Height=175.4 ± 8.7 cm; Weight=71.6 ± 12.0 kg) participated in this randomized, repeated measures, double-blind, placebo-controlled design. Maximal oxygen consumption (VO2max), time to exhaustion (TTE), and ventilatory threshold (VT) were measured during a maximal graded exercise test on a cycle ergometer. Relative peak power output (RPP), average power output (AvgP), and percent drop (%drop) were recorded during a 3-minute maximal cycle test with resistance at 4.5% body weight. Subjects consumed 4 g·d−1 mushroom blend (MR) or maltodextrin (PL) for 1 week. Ten volunteers supplemented for an additional 2 weeks. Exercise tests were separated by at least 48-hours and repeated following supplementation periods. One week of supplementation elicited no significant time × treatment interaction for VO2max (p=0.364), VT (p=0.514), TTE (p=0.540), RPP (p=0.134), AvgP (p=0.398), or %drop (p=0.823). After 3-weeks, VO2max significantly improved (p=0.042) in MR (+4.8 ml·kg−1·min−1), but not PL (+0.9 ml·kg−1·min−1). Analysis of 95% confidence intervals revealed significant improvements in TTE after 1- (+28.1 s) and 3-weeks (+69.8 s) in MR, but not PL, with additional improvements in VO2max (+4.8 ml·kg−1·min−1) and VT (+0.7 l·min−1) after 3-weeks. Acute supplementation with a cordyceps militaris containing mushroom blend may improve tolerance to high intensity exercise; greater benefits may be elicited with consistent chronic supplementation. PMID:27408987

  4. No Effect of Exercise Intensity on Appetite in Highly-Trained Endurance Women

    Science.gov (United States)

    Howe, Stephanie M.; Hand, Taryn M.; Larson-Meyer, D. Enette; Austin, Kathleen J.; Alexander, Brenda M.; Manore, Melinda M.

    2016-01-01

    In endurance-trained men, an acute bout of exercise is shown to suppress post-exercise appetite, yet limited research has examined this response in women. The purpose of this study was to investigate the effect of exercise intensity on appetite and gut hormone responses in endurance-trained women. Highly-trained women (n = 15, 18–40 years, 58.4 ± 6.4 kg, VO2MAX = 55.2 ± 4.3 mL/kg/min) completed isocaloric bouts (500 kcals or 2093 kJ) of moderate-intensity (MIE, 60% VO2MAX) and high-intensity (HIE, 85% VO2MAX) treadmill running at the same time of day, following a similar 48-h diet/exercise period, and at least 1-week apart. Blood was drawn pre-exercise (baseline), immediately post-exercise and every 20-min for the next 60-min. Plasma concentrations of acylated ghrelin, PYY3–36, GLP-1 and subjective appetite ratings via visual analog scale (VAS) were assessed at each time point. Acylated ghrelin decreased (p = 0.014) and PYY3–36 and GLP-1 increased (p = 0.036, p appetite suppression. VAS ratings of hunger and desire to eat decreased immediately post-exercise (p = 0.0012, p = 0.0031, respectively), also indicating appetite suppression. There were no differences between exercise intensities for appetite hormones or VAS. Similar to males, post-exercise appetite regulatory hormones were altered toward suppression in highly-trained women and independent of energy cost of exercise. Results are important for female athletes striving to optimize nutrition for endurance performance. PMID:27096869

  5. No Effect of Exercise Intensity on Appetite in Highly-Trained Endurance Women.

    Science.gov (United States)

    Howe, Stephanie M; Hand, Taryn M; Larson-Meyer, D Enette; Austin, Kathleen J; Alexander, Brenda M; Manore, Melinda M

    2016-04-18

    In endurance-trained men, an acute bout of exercise is shown to suppress post-exercise appetite, yet limited research has examined this response in women. The purpose of this study was to investigate the effect of exercise intensity on appetite and gut hormone responses in endurance-trained women. Highly-trained women (n = 15, 18-40 years, 58.4 ± 6.4 kg, VO2MAX = 55.2 ± 4.3 mL/kg/min) completed isocaloric bouts (500 kcals or 2093 kJ) of moderate-intensity (MIE, 60% VO2MAX) and high-intensity (HIE, 85% VO2MAX) treadmill running at the same time of day, following a similar 48-h diet/exercise period, and at least 1-week apart. Blood was drawn pre-exercise (baseline), immediately post-exercise and every 20-min for the next 60-min. Plasma concentrations of acylated ghrelin, PYY3-36, GLP-1 and subjective appetite ratings via visual analog scale (VAS) were assessed at each time point. Acylated ghrelin decreased (p = 0.014) and PYY3-36 and GLP-1 increased (p = 0.036, p exercise, indicating appetite suppression. VAS ratings of hunger and desire to eat decreased immediately post-exercise (p = 0.0012, p = 0.0031, respectively), also indicating appetite suppression. There were no differences between exercise intensities for appetite hormones or VAS. Similar to males, post-exercise appetite regulatory hormones were altered toward suppression in highly-trained women and independent of energy cost of exercise. Results are important for female athletes striving to optimize nutrition for endurance performance.

  6. High intensity hadron accelerators

    International Nuclear Information System (INIS)

    Teng, L.C.

    1989-05-01

    This rapporteur report consists mainly of two parts. Part I is an abridged review of the status of all High Intensity Hadron Accelerator projects in the world in semi-tabulated form for quick reference and comparison. Part II is a brief discussion of the salient features of the different technologies involved. The discussion is based mainly on my personal experiences and opinions, tempered, I hope, by the discussions I participated in in the various parallel sessions of the workshop. In addition, appended at the end is my evaluation and expression of the merits of high intensity hadron accelerators as research facilities for nuclear and particle physics

  7. High-Intensity Exercise Induced Oxidative Stress and Skeletal Muscle Damage in Postpubertal Boys and Girls: A Comparative Study.

    Science.gov (United States)

    Pal, Sangita; Chaki, Biswajit; Chattopadhyay, Sreya; Bandyopadhyay, Amit

    2018-04-01

    Pal, S, Chaki, B, Chattopadhyay, S, and Bandyopadhyay, A. High-intensity exercise induced oxidative stress and skeletal muscle damage in post-pubertal boys and girls: a comparative study. J Strength Cond Res 32(4): 1045-1052, 2018-The purpose of this study was to examine the sex variation in high-intensity exercise induced oxidative stress and muscle damage among 44 sedentary postpubertal boys and girls through estimation of postexercise release pattern of muscle damage markers like creatine kinase, lactate dehydrogenase (LDH), alanine aminotransferase (ALT), aspartate aminotransferase (AST) and oxidative stress markers like extent of lipid peroxidation (thiobarbituric acid-reactive substances) and catalase activity. Muscle damage markers like creatine kinase, LDH, ALT, and AST were measured before, immediately after, and 24 and 48 hours after high-intensity incremental treadmill running. Oxidative stress markers like thiobarbituric acid-reactive substances and catalase activity were estimated before and immediately after the exercise. Lipid peroxidation and serum catalase activity increased significantly in both groups after exercise (p exercise level at 24 and 48 hours after exercise in both the sexes, (p exercise, the pattern of postexercise release of these markers were found to be similar in both the groups. Accordingly, it has been concluded from the present investigation that high-intensity exercise induces significant oxidative stress and increases indices of skeletal muscle damage in both postpubertal girls and boys. However, postpubertal girls are relatively better protected from oxidative stress and muscle damage as compared to the boys of similar age and physical activity level. It is further evident that sex difference may not be apparent for all the biomarkers of muscle damage in this age group.

  8. Men and Women Exhibit Similar Acute Hypotensive Responses After Low, Moderate, or High-Intensity Plyometric Training.

    Science.gov (United States)

    Ramírez-Campillo, Rodrigo; Abad-Colil, Felipe; Vera, Maritza; Andrade, David C; Caniuqueo, Alexis; Martínez-Salazar, Cristian; Nakamura, Fábio Y; Arazi, Hamid; Cerda-Kohler, Hugo; Izquierdo, Mikel; Alonso-Martínez, Alicia M

    2016-01-01

    The aim of this study was to compare the acute effects of low-, moderate-, high-, and combined-intensity plyometric training on heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), and rate-pressure product (RPP) cardiovascular responses in male and female normotensive subjects. Fifteen (8 women) physically active normotensive subjects participated in this study (age 23.5 ± 2.6 years, body mass index 23.8 ± 2.3 kg · m(-2)). Using a randomized crossover design, trials were conducted with rest intervals of at least 48 hours. Each trial comprised 120 jumps, using boxes of 20, 30, and 40 cm for low, moderate, and high intensity, respectively. For combined intensity, the 3 height boxes were combined. Measurements were taken before and after (i.e., every 10 minutes for a period of 90 minutes) each trial. When data responses of men and women were combined, a mean reduction in SBP, DBP, and RPP was observed after all plyometric intensities. No significant differences were observed pre- or postexercise (at any time point) for HR, SBP, DBP, or RPP when low-, moderate-, high-, or combined-intensity trials were compared. No significant differences were observed between male and female subjects, except for a higher SBP reduction in women (-12%) compared with men (-7%) after high-intensity trial. Although there were minor differences across postexercise time points, collectively, the data demonstrated that all plyometric training intensities can induce an acute postexercise hypotensive effect in young normotensive male and female subjects.

  9. Environmental persistence of OXA-48-producing Klebsiella pneumoniae in a French intensive care unit.

    Science.gov (United States)

    Pantel, Alix; Richaud-Morel, Brigitte; Cazaban, Michel; Bouziges, Nicole; Sotto, Albert; Lavigne, Jean-Philippe

    2016-03-01

    The spread of carbapenemase-producing Gram-negative rods is an emerging global problem. This study describes the epidemiologic features of an outbreak caused by an environmental reservoir of OXA-48-producing Klebsiella pneumoniae caused by persistence of the bacteria during 20 months in an intensive care unit in France. This report emphasizes the importance of early environmental screening to interrupt the transmission of carbapenemase-producingEnterobacteriaceae. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  10. Studies of highly ionized atoms using internal conversion: 197Au, 57Fe; electric monopole transitions in 40Ca, 42Ca, and 44Ca

    International Nuclear Information System (INIS)

    Ulrickson, M.A.

    1975-01-01

    By using heavy-ion reactions, highly ionized electronic states of atoms may be produced. The interaction between excited nuclear levels and the surrounding atomic electrons via internal conversion allows the nucleus to be used as a probe of the electronic structure of the highly ionized atoms. Studies of such atoms were undertaken for strongly internally converted nuclear levels in 197 Au and 57 Fe. The nuclear levels were Coulomb excited by using 16 O and 32 S beams. Simultaneous measurement of the lifetime of the 77-keV state of 197 Au in both neutral gold atoms and gold atoms with mean charge +10 resulted in a measured change in the internal conversion coefficient of Δalpha/alpha equals - 1.7 +- 3.0)10 -3 . This result is consistent with calculations using a Hartree-Fock--Slater program. Measurements of the electric monopole strengths for 0 + → 0 + transitions were undertaken to determine the amount of core-deformation in calcium nuclei. The E0 strengths for the decays of the 0 + states at 5.21 MeV in 40 C, 1.84 MeV in 42 Ca, and 1.88 MeV in 44 Ca were observed. The branching ratios for the subsequent E0 pair decays were measured by observing the coincident annihilation radiation from the e + member of the pair in coincidence with protons feeding the state in the cases of 42 Ca and 44 Ca, and by observing the actual coincident e + --e - pair together with protons feeding the state in the case of 40 Ca. The resulting E0 strengths (rho less than or equal to 0.06, rho = 0.34 +- 0.03, rho = 0.30 +- 0.10 for 40 Ca, 42 Ca, and 44 Ca respectively) agree with theoretical descriptions

  11. Highly aqueous soluble CaF2:Ce/Tb nanocrystals: effect of surface functionalization on structural, optical band gap, and photoluminescence properties.

    Science.gov (United States)

    Ansari, Anees A; Parchur, Abdul K; Kumar, Brijesh; Rai, S B

    2016-12-01

    The design of nanostructured materials with highly stable water-dispersion and luminescence efficiency is an important concern in nanotechnology and nanomedicine. In this paper, we described the synthesis and distinct surface modification on the morphological structure and optical (optical absorption, band gap energy, excitation, emission, decay time, etc.) properties of highly crystalline water-dispersible CaF 2 :Ce/Tb nanocrystals (core-nanocrystals). The epitaxial growth of inert CaF 2 and silica shell, respectively, on their surface forming as CaF 2 :Ce/Tb@CaF 2 (core/shell) and CaF 2 :Ce/Tb@CaF 2 @SiO 2 (core/shell/SiO 2 ) nanoarchitecture. X-ray diffraction and transmission electron microscope image shows that the nanocrystals were in irregular spherical phase, highly crystalline (~20 nm) with narrow size distribution. The core/shell nanocrystals confirm that the surface coating is responsible in the change of symmetrical nanostructure, which was determined from the band gap energy and luminescent properties. It was found that an inert inorganic shell formation effectively enhances the luminescence efficiency and silica shell makes the nanocrystals highly water-dispersible. In addition, Ce 3+ /Tb 3+ -co-doped CaF 2 nanocrystals show efficient energy transfer from Ce 3+ to Tb 3+ ion and strong green luminescence of Tb 3+ ion at 541 nm( 5 D 4 → 7 F 5 ). Luminescence decay curves of core and core/shell nanocrystals were fitted using mono and biexponential equations, and R 2 regression coefficient criteria were used to discriminate the goodness of the fitted model. The lifetime values for the core/shell nanocrystals are higher than core-nanocrystals. Considering the high stable water-dispersion and intensive luminescence emission in the visible region, these luminescent core/shell nanocrystals could be potential candidates for luminescent bio-imaging, optical bio-probe, displays, staining, and multianalyte optical sensing. A newly designed CaF 2 :Ce

  12. 'J-KAREN' - high intensity, high contrast laser

    International Nuclear Information System (INIS)

    Kiriyama, Hiromitsu; Mori, Michiaki; Nakai, Yoshiki; Okada, Hajime; Sasao, Hajime; Sagisaka, Akito; Ochi, Yoshihiro; Tanaka, Momoko; Kondo, Kiminori; Tateno, Ryo; Sugiyama, Akira; Daido, Hiroyuki; Koike, Masato; Kawanishi, Syunichi; Shimomura, Takuya; Tanoue, Manabu; Wakai, Daisuke; Kondo, Shuji; Kanazawa, Shuhei

    2010-01-01

    We report on the high intensity, high contrast double chirped-pulse amplification (CPA) Ti:sapphire laser system (named J-KAREN). By use of an optical parametric chirped-pulse amplification (OPCPA) preamplifier that is seeded by a cleaned high-energy pulse, a background amplified spontaneous emission (ASE) level of 10 -10 relative to the peak main femtosecond pulse on the picosecond timescales demonstrated with an output energy of 1.7 J and a pulse duration of 30 fs, corresponding to a peak power of 60TW at a 10 Hz repetition rate. This system which uses a cryogenically-cooled Ti:sapphire final amplifier generates focused peak intensity in excess of 10 20 W/cm 2 at a 10 Hz repetition rate. (author)

  13. Generation of intense high-order vortex harmonics.

    Science.gov (United States)

    Zhang, Xiaomei; Shen, Baifei; Shi, Yin; Wang, Xiaofeng; Zhang, Lingang; Wang, Wenpeng; Xu, Jiancai; Yi, Longqiong; Xu, Zhizhan

    2015-05-01

    This Letter presents for the first time a scheme to generate intense high-order optical vortices that carry orbital angular momentum in the extreme ultraviolet region based on relativistic harmonics from the surface of a solid target. In the three-dimensional particle-in-cell simulation, the high-order harmonics of the high-order vortex mode is generated in both reflected and transmitted light beams when a linearly polarized Laguerre-Gaussian laser pulse impinges on a solid foil. The azimuthal mode of the harmonics scales with its order. The intensity of the high-order vortex harmonics is close to the relativistic region, with the pulse duration down to attosecond scale. The obtained intense vortex beam possesses the combined properties of fine transversal structure due to the high-order mode and the fine longitudinal structure due to the short wavelength of the high-order harmonics. In addition to the application in high-resolution detection in both spatial and temporal scales, it also presents new opportunities in the intense vortex required fields, such as the inner shell ionization process and high energy twisted photons generation by Thomson scattering of such an intense vortex beam off relativistic electrons.

  14. Low-intensity interval exercise training attenuates coronary vascular dysfunction and preserves Ca2+-sensitive K+ current in miniature swine with LV hypertrophy

    Science.gov (United States)

    Tharp, Darla L.; Ivey, Jan R.; Ganjam, Venkataseshu K.; Bowles, Douglas K.

    2011-01-01

    Coronary vascular dysfunction has been observed in several models of heart failure (HF). Recent evidence indicates that exercise training is beneficial for patients with HF, but the precise intensity and underlying mechanisms are unknown. Left ventricular (LV) hypertrophy can play a significant role in the development of HF; therefore, the purpose of this study was to assess the effects of low-intensity interval exercise training on coronary vascular function in sedentary (HF) and exercise trained (HF-TR) aortic-banded miniature swine displaying LV hypertrophy. Six months postsurgery, in vivo coronary vascular responses to endothelin-1 (ET-1) and adenosine were measured in the left anterior descending coronary artery. Baseline and maximal coronary vascular conductance were similar between all groups. ET-1-induced reductions in coronary vascular conductance (P < 0.05) were greater in HF vs. sedentary control and HF-TR groups. Pretreatment with the ET type A (ETA) receptor blocker BQ-123 prevented ET-1 hypersensitivity in HF animals. Whole cell voltage clamp was used to characterize composite K+ currents (IK+) in coronary smooth muscle cells. Raising internal Ca2+ from 200 to 500 nM increased Ca2+-sensitive K+ current in HF-TR and control, but not HF animals. In conclusion, an ETA-receptor-mediated hypersensitivity to ET-1, elevated resting LV wall tension, and decreased coronary smooth muscle cell Ca2+-sensitive IK+ was found in sedentary animals with LV hypertrophy. Low-intensity interval exercise training preserved normal coronary vascular function and smooth muscle cell Ca2+-sensitive IK+, illustrating a potential mechanism underlying coronary vascular dysfunction in a large-animal model of LV hypertrophy. Our results demonstrate the potential clinical impact of exercise on coronary vascular function in HF patients displaying pathological LV hypertrophy. PMID:21841018

  15. Concentration effect on inter-mineral equilibrium isotope fractionation: insights from Mg and Ca isotopic systems

    Science.gov (United States)

    Huang, F.; Wang, W.; Zhou, C.; Kang, J.; Wu, Z.

    2017-12-01

    Many naturally occurring minerals, such as carbonate, garnet, pyroxene, and feldspar, are solid solutions with large variations in chemical compositions. Such variations may affect mineral structures and modify the chemical bonding environment around atoms, which further impacts the equilibrium isotope fractionation factors among minerals. Here we investigated the effects of Mg content on equilibrium Mg and Ca isotope fractionation among carbonates and Ca content on equilibrium Ca isotope fractionation between orthopyroxene (opx) and clinopyroxene (cpx) using first-principles calculations. Our results show that the average Mg-O bond length increases with decreasing Mg/(Mg+Ca) in calcite when it is greater than 1/48[1] and the average Ca-O bond length significantly decreases with decreasing Ca/(Ca+Mg+Fe) in opx when it ranges from 2/16 to 1/48[2]. Equilibrium isotope fractionation is mainly controlled by bond strengths, which could be measured by bond lengths. Thus, 103lnα26Mg/24Mg between dolomite and calcite dramatically increases with decreasing Mg/(Mg+Ca) in calcite [1] and it reaches a constant value when it is lower than 1/48. 103lnα44Ca/40Ca between opx and cpx significantly increases with decreasing Ca content in opx when Ca/(Ca+Mg+Fe) ranges from 2/16 to 1/48 [2]. If Ca/(Ca+Mg+Fe) is below 1/48, 103lnα44Ca/40Ca is not sensitive to Ca content. Based on our results, we conclude that the concentration effect on equilibrium isotope fractionation could be significant within a certain range of chemical composition of minerals, which should be a ubiquitous phenomenon in solid solution systems. [1] Wang, W., Qin, T., Zhou, C., Huang, S., Wu, Z., Huang, F., 2017. GCA 208, 185-197. [2] Feng, C., Qin, T., Huang, S., Wu, Z., Huang, F., 2014. GCA 143, 132-142.

  16. Concept for a new high resolution high intensity diffractometer

    Energy Technology Data Exchange (ETDEWEB)

    Stuhr, U [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    A concept of a new time-of-flight powder-diffractometer for a thermal neutral beam tube at SINQ is presented. The design of the instrument optimises the contradictory conditions of high intensity and high resolution. The high intensity is achieved by using many neutron pulses simultaneously. By analysing the time-angle-pattern of the detected neutrons an assignment of the neutrons to a single pulse is possible. (author) 3 figs., tab., refs.

  17. High-intensity interval training and β-hydroxy-β-methylbutyric free acid improves aerobic power and metabolic thresholds

    OpenAIRE

    Robinson, Edward H; Stout, Jeffrey R; Miramonti, Amelia A; Fukuda, David H; Wang, Ran; Townsend, Jeremy R; Mangine, Gerald T; Fragala, Maren S; Hoffman, Jay R

    2014-01-01

    Background Previous research combining Calcium β-hydroxy-β-methylbutyrate (CaHMB) and running high-intensity interval training (HIIT) have shown positive effects on aerobic performance measures. The purpose of this study was to examine the effect of β-hydroxy-β-methylbutyric free acid (HMBFA) and cycle ergometry HIIT on maximal oxygen consumption (VO2peak), ventilatory threshold (VT), respiratory compensation point (RCP) and time to exhaustion (Tmax) in college-aged men and women. Methods Thi...

  18. Absolute Ca Isotopic Measurement Using an Improved Double Spike Technique

    Directory of Open Access Journals (Sweden)

    Jason Jiun-San Shen

    2009-01-01

    Full Text Available A new vector analytical method has been developed in order to obtain the true isotopic composition of the 42Ca-48Ca double spike. This is achieved by using two different sample-spike mixtures combined with the double spike and natural Ca data. Be cause the natural sample (two mixtures and the spike should all lie on a single mixing line, we are able to con strain the true isotopic composition of our double spike using this new approach. Once the isotopic composition of the Ca double spike is established, we are able to obtain the true Ca isotopic composition of the NIST Ca standard SRM915a, 40Ca/44Ca = 46.537 ± 2 (2sm, n = 55, 42Ca/44Ca = 0.31031 ± 1, 43Ca/44Ca = 0.06474 ± 1, and 48Ca/44Ca = 0.08956 ± 1. De spite an off set of 1.3% in 40Ca/44Ca between our result and the previously re ported value (Russell et al. 1978, our data indicate an off set of 1.89__in 40Ca/44Ca between SRM915a and seawater, entirely consistent with the published results.

  19. Post-perovskite transitions in CaB4+O3 at high pressure

    International Nuclear Information System (INIS)

    Akaogi, M; Shirako, Y; Kojitani, H; Takamori, S; Yamaura, K; Takayama-Muromachi, E

    2010-01-01

    High-pressure phase transitions in CaRhO 3 were examined using a multianvil apparatus up to 27 GPa and 1930 o C. CaRhO 3 perovskite transforms to post-perovskite via a monoclinic intermediate phase with increasing pressure. Volume changes for the transitions of perovskite - intermediate phase and of intermediate phase - post-perovskite are -1.1 and -0.7 %, respectively. CaRhO 3 post-perovskite is the fourth quenchable post-perovskite oxide found so far. By high-temperature calorimetric experiments, enthalpy of the perovskite - post-perovskite transition in CaRuO 3 was measured as 15.2±3.3 kJ/mol. Combining the datum with those of CaIrO 3 , it is shown that CaIrO 3 perovskite is energetically less stable than CaRuO 3 perovskite. This is consistent with the fact that orthorhombic distortion of CaIrO 3 perovskite is larger than CaRuO 3 , as indicated with the tilt-angle of octahedral framework of perovskite structure. The transition pressure from perovskite to post-perovskite in CaBO 3 (B = Ru, Rh, Ir) increases almost linearly with decreasing the tilt-angle, suggesting that the perovskite - post-perovskite transition may result from instability of the perovskite structure with pressure.

  20. Study of the role of complete fusion in the reaction of /sup 48/Ca and /sup 56/Fe with cerium and terbium. [Cross sections, yield curves, tables

    Energy Technology Data Exchange (ETDEWEB)

    Morrissey, D.J.

    1978-05-01

    /sup 48/Ca and /sup 56/Fe beams from the Super HILAC accelerator were used to irradiate thick metal foils of cerium and terbium. Product gamma ray activities were detected offline and individual products were identified by half-life, gamma ray energy and gamma ray abundances. The production cross sections were iteratively fit to charge and mass dispersions to allow correction for parent decay and calculation of mass yields. From the mass yield curves contributions from quasielastic transfer, deep inelastic transfer and complete fusion reaction mechanisms were interred. Complete fusion was made up on contributions from both evaporation residue and fusion-fission products for the /sup 48/Ca induced reactions. However, only fusion-fission products were detected in the /sup 56/Fe induced reactions. Critical angular momenta for fusion were found to be 82 +- 8 h for /sup 48/Ca + /sup 159/Tb and 34 +- 5 h for /sup 56/Fe + /sup 140/Ce, which can be compared with 53 +- 8 h for /sup 12/C + /sup 197/Au (Natowitz, 1970) and 86 +- 5 h for /sup 40/Ar + /sup 165/Ho (Hanappe, 1973). All of these reactions lead to essentially the same compound nucleus and seem to show the dramatic decline in complete fusion for heavy ions larger than /sup 40/Ar. The prediction of this decline was found to be beyond the model calculations of Bass and the critical distance approach of Glas and Mosel.

  1. Feasibility of high-intensity training in asthma

    DEFF Research Database (Denmark)

    Tønnesen, Louise Lindhardt; Sørensen, E D; Hostrup, Morten

    2018-01-01

    Background: High-intensity interval training is an effective and popular training regime but its feasibility in untrained adults with asthma is insufficiently described. Objective: The randomized controlled trial 'EFFORT Asthma' explored the effects of behavioural interventions including high......-intensity interval training on clinical outcomes in nonobese sedentary adults with asthma. In this article we present a sub analysis of data aiming to evaluate if patients' pre-intervention levels of asthma control, FEV1, airway inflammation and airway hyperresponsiveness (AHR) predicted their training response...... to the high-intensity interval training program, measured as increase in maximal oxygen consumption (VO2max). Design: We used data from the EFFORT Asthma Study. Of the 36 patients randomized to the 8-week exercise intervention consisting of high-intensity training three times per week, 29 patients (45...

  2. First superheavy element experiments at the GSI recoil separator TASCA: The production and decay of element 114 in the 244Pu(48Ca,3-4n) reaction

    International Nuclear Information System (INIS)

    Gates, J. M.; Duellmann, Ch. E.; Schaedel, M.; Ackermann, D.; Block, M.; Bruechle, W.; Essel, H. G.; Hartmann, W.; Hessberger, F. P.; Huebner, A.; Jaeger, E.; Khuyagbaatar, J.; Kindler, B.; Krier, J.; Kurz, N.; Lommel, B.; Schaffner, H.; Schausten, B.; Schimpf, E.; Steiner, J.

    2011-01-01

    Experiments with the new recoil separator, Transactinide Separator and Chemistry Apparatus (TASCA), at the GSI were performed by using beams of 48 Ca to irradiate targets of 206-208 Pb, which led to the production of 252-254 No isotopes. These studies allowed for evaluation of the performance of TASCA when coupled to a new detector and electronics system. By following these studies, the isotopes of element 114 ( 288-291 114) were produced in irradiations of 244 Pu targets with 48 Ca beams at compound nucleus excitation energies around 41.7 and 37.5 MeV, demonstrating TASCA's ability to perform experiments with picobarn-level cross sections. A total of 15 decay chains were observed and were assigned to the decay of 288-291 114. A new α-decay branch in 281 Ds was observed, leading to the new nucleus 277 Hs.

  3. High-frequency, high-intensity photoionization

    Science.gov (United States)

    Reiss, H. R.

    1996-02-01

    Two analytical methods for computing ionization by high-frequency fields are compared. Predicted ionization rates compare well, but energy predictions for the onset of ionization differ radically. The difference is shown to arise from the use of a transformation in one of the methods that alters the zero from which energy is measured. This alteration leads to an apparent energy threshold for ionization that can, especially in the stabilization regime, differ strongly from the laboratory measurement. It is concluded that channel closings in intense-field ionization can occur at high as well as low frequencies. It is also found that the stabilization phenomenon at high frequencies, very prominent for hydrogen, is absent in a short-range potential.

  4. High-Order Ca(II)-Chloro Complexes in Mixed CaCl2-LiCl Aqueous Solution: Insights from Density Functional Theory and Molecular Dynamics Simulations.

    Science.gov (United States)

    Wang, Yu-Lin; Wang, Ying; Yi, Hai-Bo

    2016-07-21

    In this study, the structural characteristics of high-coordinated Ca-Cl complexes present in mixed CaCl2-LiCl aqueous solution were investigated using density functional theory (DFT) and molecular dynamics (MD) simulations. The DFT results show that [CaClx](2-x) (x = 4-6) clusters are quite unstable in the gas phase, but these clusters become metastable when hydration is considered. The MD simulations show that high-coordinated Ca-chloro complexes are possible transient species that exist for up to nanoseconds in concentrated (11.10 mol·kg(-1)) Cl(-) solution at 273 and 298 K. As the temperature increases to 423 K, these high-coordinated structures tend to disassociate and convert into smaller clusters and single free ions. The presence of high-order Ca-Cl species in concentrated LiCl solution can be attributed to their enhanced hydration shell and the inadequate hydration of ions. The probability of the [CaClx](2-x)aq (x = 4-6) species being present in concentrated LiCl solution decreases greatly with increasing temperature, which also indicates that the formation of the high-coordinated Ca-Cl structure is related to its hydration characteristics.

  5. The role of annealing: effect on CaSO4:Dy phosphor with manganese and sodium impurities

    International Nuclear Information System (INIS)

    Li, S.-H.; Hsu, P.-C.

    1990-01-01

    The effect of the annealing treatment on the CaSO 4 :Dy phosphor with Mn and Na impurities was studied at different annealing temperatures from 100 0 C to 800 0 C. Doping with or without impurity caused no difference in the properties for temperatures less than 400 0 C. An annealing temperature greater than 400 0 C brings a reduction in low temperature peak intensities of CaSO 4 :Dy with Na only. The high temperature peak intensities increase as the temperature increases from 400 0 C to 600 0 C. However, annealing at a temperature greater than 600 0 C brings a drastic reduction in high temperature peak intensities as well as TL output. (author)

  6. The impact of brief high-intensity exercise on blood glucose levels

    Directory of Open Access Journals (Sweden)

    Adams OP

    2013-02-01

    Full Text Available O Peter AdamsFaculty of Medical Sciences, the University of the West Indies, Cave Hill Campus, St Michael, BarbadosBackground: Moderate-intensity exercise improves blood glucose (BG, but most people fail to achieve the required exercise volume. High-intensity exercise (HIE protocols vary. Maximal cycle ergometer sprint interval training typically requires only 2.5 minutes of HIE and a total training time commitment (including rest and warm up of 25 minutes per session. The effect of brief high-intensity exercise on blood glucose levels of people with and without diabetes is reviewed.Methods: HIE (≥80% maximal oxygen uptake, VO2max studies with ≤15 minutes HIE per session were reviewed.Results: Six studies of nondiabetics (51 males, 14 females requiring 7.5 to 20 minutes/week of HIE are reviewed. Two weeks of sprint interval training increased insulin sensitivity up to 3 days postintervention. Twelve weeks near maximal interval running (total exercise time 40 minutes/week improved BG to a similar extent as running at 65% VO2max for 150 minutes/week. Eight studies of diabetics (41 type 1 and 22 type 2 subjects were reviewed. Six were of a single exercise session with 44 seconds to 13 minutes of HIE, and the others were 2 and 7 weeks duration with 20 and 2 minutes/week HIE, respectively. With type 1 and 2 diabetes, BG was generally higher during and up to 2 hours after HIE compared to controls. With type 1 diabetics, BG decreased from midnight to 6 AM following HIE the previous morning. With type 2 diabetes, a single session improved postprandial BG for 24 hours, while a 2-week program reduced the average BG by 13% at 48 to 72 hours after exercise and also increased GLUT4 by 369%.Conclusion: Very brief HIE improves BG 1 to 3 days postexercise in both diabetics and nondiabetics. HIE is unlikely to cause hypoglycemia during and immediately after exercise. Larger and longer randomized studies are needed to determine the safety, acceptability, long

  7. Nonisothermal Thermogravimetric Analysis of Thai Lignite with High CaO Content

    Science.gov (United States)

    Pintana, Pakamon

    2013-01-01

    Thermal behaviors and combustion kinetics of Thai lignite with different SO3-free CaO contents were investigated. Nonisothermal thermogravimetric method was carried out under oxygen environment at heating rates of 10, 30, and 50°C min−1 from ambient up to 1300°C. Flynn-Wall-Ozawa (FWO) and Kissinger-Akahira-Sunose (KAS) methods were adopted to estimate the apparent activation energy (E) for the thermal decomposition of these coals. Different thermal degradation behaviors were observed in lignites with low (14%) and high (42%) CaO content. Activation energy of the lignite combustion was found to vary with the conversion fraction. In comparison with the KAS method, higher E values were obtained by the FWO method for all conversions considered. High CaO lignite was observed to have higher activation energy than the low CaO coal. PMID:24250259

  8. Line list for the ground state of CaF

    Science.gov (United States)

    Hou, Shilin; Bernath, Peter F.

    2018-05-01

    The molecular potential energy function and electronic dipole moment function for the ground state of CaF were studied with MRCI, ACPF, and RCCSD(T) ab initio calculations. The RCCSD(T) potential function reproduces the experimental vibrational intervals to within ∼2 cm-1. The RCCSD(T) dipole moment at the equilibrium internuclear separation agrees well with the experimental value. Over a wide range of internuclear separations, far beyond the range associated with the observed spectra, the ab initio dipole moment functions are similar and highly linear. An extended Morse oscillator (EMO) potential function was also obtained by fitting the observed lines of the laboratory vibration-rotation and pure rotation spectra of the 40CaF X2Σ+ ground state. The fitted potential reproduces the observed transitions (v ≤ 8, N ≤ 121, Δv = 0, 1) within their experimental uncertainties. With this EMO potential and the RCCSD(T) dipole moment function, line lists for 40CaF, 42CaF, 43CaF, 44CaF, 46CaF, and 48CaF were computed for v ≤ 10, N ≤ 121, Δv = 0-10. The calculated emission spectra are in good agreement with an observed laboratory spectrum of CaF at a sample temperature of 1873 K.

  9. Development of high intensity beam handling system, 4

    International Nuclear Information System (INIS)

    Yamanoi, Yutaka; Tanaka, Kazuhiro; Minakawa, Michifumi

    1992-01-01

    We have constructed the new counter experimental hall at the KEK 12 GeV Proton Synchrotron (KEK-PS) in order to handle high intensity primary proton beams of up to 1x10 3 pps (protons per second), which is one order of magnitude greater than the present beam intensity of the KEK-PS, 1x10 12 pps. New technologies for handling high-intensity beams have, then, been developed and employed in the construction of the new hall. A part of our R/D work on handling high intensity beams will be reported. (author)

  10. High Intensity Source Laboratory (HISL)

    International Nuclear Information System (INIS)

    1992-01-01

    The High Intensity Source Laboratory (HISL) is a laboratory facility operated for the US Department of Energy (DOE) by EG ampersand G, Energy Measurements (EG ampersand G/EM). This document is intended as an overview -- primarily for external users -- of the general purposes and capabilities of HISL; numerous technical details are beyond its scope. Moreover, systems at HISL are added, deleted, and modified to suit current needs, and upgraded with continuing development. Consequently, interested parties are invited to contact the HISL manager for detailed, current, technical, and administrative information. The HISL develops and operates pulsed radiation sources with energies, intensities, and pulse widths appropriate for several applications. Principal among these are development, characterization, and calibration of various high-bandwidth radiation detectors and diagnostic systems. Hardness/vulnerability of electronic or other sensitive components to radiation is also tested. In this connection, source development generally focuses on attending (1) the highest possible intensities with (2) reasonably short pulse widths and (3) comprehensive output characterization

  11. Observation of the new neutron-rich nuclei 29F, 35,36Mg, 38,39Al, 40,41Si, 43,44P, 45,46,47S, 46,47,48,49Cl and 49,50,51Ar by means of a 55 MeV/u 48Ca beam

    International Nuclear Information System (INIS)

    Guillemaud-Mueller, D.; Anne, R.; Penionzhkevich, Yu.Eh.

    1988-01-01

    Using magnetic separation and identification through time of flight and ΔE,E measurements, the new neutron-rich nuclei, 29 F, 35,36 Mg, 38,39 Al, 40,41 Si, 43,44 P, 45,46,47 S, 46,47,48,49 Cl, 49,50,51 Ar have been observed from interactions of 48 Ca beam of 55 MeV/u with tantalum targets

  12. High-pressure synthesis and structural, physical properties of CaIr1-xPtxO3 and CaIr1-xRhxO3

    Science.gov (United States)

    Hirai, S.; Bromiley, G. D.; Klemme, S.; Irifune, T.; Ohfuji, H.; Attfield, P.; Nishiyama, N.

    2010-12-01

    Since the discovery of the perovskite to post-perovskite transition in MgSiO3 in a laser-heated DAC, wide attention has been focussed on the post-perovskite phase of MgSiO3. This is because the post-perovskite phase is likely to play a key role in Earth’s lowermost mantle, and because the perovskite to post-perovskite transition can explain many features of the D” seismic discontinuity. While it is meaningful to conduct further studies of MgSiO3, the post-perovskite phase of MgSiO3 cannot be quenched to ambient pressure/temperature conditions. Thus, further studies must be conducted using analogue compounds of MgSiO3 post-perovskite, which are quenchable to ambient pressure/temperature conditions. The post-perovskite phase of MgSiO3 crystallizes in a layered structure with CaIrO3-structure. Therefore, it is useful to investigate compounds with CaIrO3-structure. There are only four quenchable oxides with CaIrO3-structure reported to date: CaIrO3, CaPtO3, CaRhO3 and CaRuO3. CaIrO3 can be synthesized at ambient pressure, whilst the other three oxides can only be obtained at high pressure/temperature conditions using a multi-anvil apparatus. Further studies on these materials have revealed structural phase transitions at high P-T and a metal-insulator transition by hole doping. In the case of CaIrO3, The post-perovskite phase of CaIrO3 synthesized at 2GPa, 1373K transforms into a perovskite phase at 2GPa, 1673K. In other words, the perovskite phase can be synthesized at temperatures higher than those needed for synthesizing the post-perovskite phase. This is also the case for CaRhO3 (6GPa, 1873K) and CaRuO3 (23GPa, 1343K), while CaPtO3 remained post-perovskite at higher temperatures. We have succeeded in synthesizing solid solutions between CaIrO3, CaPtO3 and CaRhO3. We have found the systematic change in structural and physical properties of post-perovskite oxides, with composition and P-T, which broadens the future opportunity for studying post-perovskite systems

  13. The mast cell degranulator compound 48/80 directly activates neurons.

    Directory of Open Access Journals (Sweden)

    Michael Schemann

    Full Text Available BACKGROUND: Compound 48/80 is widely used in animal and tissue models as a "selective" mast cell activator. With this study we demonstrate that compound 48/80 also directly activates enteric neurons and visceral afferents. METHODOLOGY/PRINCIPAL FINDINGS: We used in vivo recordings from extrinsic intestinal afferents together with Ca(++ imaging from primary cultures of DRG and nodose neurons. Enteric neuronal activation was examined by Ca(++ and voltage sensitive dye imaging in isolated gut preparations and primary cultures of enteric neurons. Intraluminal application of compound 48/80 evoked marked afferent firing which desensitized on subsequent administration. In egg albumen-sensitized animals, intraluminal antigen evoked a similar pattern of afferent activation which also desensitized on subsequent exposure to antigen. In cross-desensitization experiments prior administration of compound 48/80 failed to influence the mast cell mediated response. Application of 1 and 10 µg/ml compound 48/80 evoked spike discharge and Ca(++ transients in enteric neurons. The same nerve activating effect was observed in primary cultures of DRG and nodose ganglion cells. Enteric neuron cultures were devoid of mast cells confirmed by negative staining for c-kit or toluidine blue. In addition, in cultured enteric neurons the excitatory action of compound 48/80 was preserved in the presence of histamine H(1 and H(2 antagonists. The mast cell stabilizer cromolyn attenuated compound 48/80 and nicotine evoked Ca(++ transients in mast cell-free enteric neuron cultures. CONCLUSIONS/SIGNIFICANCE: The results showed direct excitatory action of compound 48/80 on enteric neurons and visceral afferents. Therefore, functional changes measured in tissue or animal models may involve a mast cell independent effect of compound 48/80 and cromolyn.

  14. Isospin influence on the decay modes of compound systems produced in the 78,86Kr + 40,48Ca at 10 AMeV

    Directory of Open Access Journals (Sweden)

    Pirrone S.

    2016-01-01

    Full Text Available The study of the decay modes competition of the compound systems produced in the collisions 78Kr+40Ca and 86Kr+48Ca at 10AMeV is presented. In particular, the N/Z entrance channel influence on the decay paths of the compound systems, directly connected to the isospin influence, is investigated. The experiment was performed at the INFN Laboratori Nazionali del Sud (LNS in Catania by using the 4π multi-detector CHIMERA. Charge, mass, angular distributions and kinematical features of the reaction products were studied. The analysis shows some differences in the contribution arising from the various reaction mechanisms for the neutron poor and neutron rich systems. Comparison with theoretical statistical and dynamical models are presented for the two systems. Besides a study of the influence of the energy on the entrance channel is performed for the 78Kr+40Ca reaction, by comparing the results of this experiment to those obtained for the same system at 5.5 AMeV with the INDRA device at GANIL.

  15. High Intensity High Charge State ECR Ion Sources

    CERN Document Server

    Leitner, Daniela

    2005-01-01

    The next-generation heavy ion beam accelerators such as the proposed Rare Isotope Accelerator (RIA), the Radioactive Ion Beam Factory at RIKEN, the GSI upgrade project, the LHC-upgrade, and IMP in Lanzhou require a great variety of high charge state ion beams with a magnitude higher beam intensity than currently achievable. High performance Electron Cyclotron Resonance (ECR) ion sources can provide the flexibility since they can routinely produce beams from hydrogen to uranium. Over the last three decades, ECR ion sources have continued improving the available ion beam intensities by increasing the magnetic fields and ECR heating frequencies to enhance the confinement and the plasma density. With advances in superconducting magnet technology, a new generation of high field superconducting sources is now emerging, designed to meet the requirements of these next generation accelerator projects. The talk will briefly review the field of high performance ECR ion sources and the latest developments for high intens...

  16. Photon-photon scattering at the high-intensity frontier

    Science.gov (United States)

    Gies, Holger; Karbstein, Felix; Kohlfürst, Christian; Seegert, Nico

    2018-04-01

    The tremendous progress in high-intensity laser technology and the establishment of dedicated high-field laboratories in recent years have paved the way towards a first observation of quantum vacuum nonlinearities at the high-intensity frontier. We advocate a particularly prospective scenario, where three synchronized high-intensity laser pulses are brought into collision, giving rise to signal photons, whose frequency and propagation direction differ from the driving laser pulses, thus providing various means to achieve an excellent signal to background separation. Based on the theoretical concept of vacuum emission, we employ an efficient numerical algorithm which allows us to model the collision of focused high-intensity laser pulses in unprecedented detail. We provide accurate predictions for the numbers of signal photons accessible in experiment. Our study is the first to predict the precise angular spread of the signal photons, and paves the way for a first verification of quantum vacuum nonlinearity in a well-controlled laboratory experiment at one of the many high-intensity laser facilities currently coming online.

  17. High-pressure X-ray diffraction and Raman spectroscopy of CaFe2O4-type β-CaCr2O4

    Science.gov (United States)

    Zhai, Shuangmeng; Yin, Yuan; Shieh, Sean R.; Shan, Shuangming; Xue, Weihong; Wang, Ching-Pao; Yang, Ke; Higo, Yuji

    2016-04-01

    In situ high-pressure synchrotron X-ray diffraction and Raman spectroscopic studies of orthorhombic CaFe2O4-type β-CaCr2O4 chromite were carried out up to 16.2 and 32.0 GPa at room temperature using multi-anvil apparatus and diamond anvil cell, respectively. No phase transition was observed in this study. Fitting a third-order Birch-Murnaghan equation of state to the P-V data yields a zero-pressure volume of V 0 = 286.8(1) Å3, an isothermal bulk modulus of K 0 = 183(5) GPa and the first pressure derivative of isothermal bulk modulus K 0' = 4.1(8). Analyses of axial compressibilities show anisotropic elasticity for β-CaCr2O4 since the a-axis is more compressible than the b- and c-axis. Based on the obtained and previous results, the compressibility of several CaFe2O4-type phases was compared. The high-pressure Raman spectra of β-CaCr2O4 were analyzed to determine the pressure dependences and mode Grüneisen parameters of Raman-active bands. The thermal Grüneisen parameter of β-CaCr2O4 is determined to be 0.93(2), which is smaller than those of CaFe2O4-type CaAl2O4 and MgAl2O4.

  18. High-pressure behavior of CaMo O4

    Science.gov (United States)

    Panchal, V.; Garg, N.; Poswal, H. K.; Errandonea, D.; Rodríguez-Hernández, P.; Muñoz, A.; Cavalli, E.

    2017-09-01

    We report a high-pressure study of tetragonal scheelite-type CaMo O4 up to 29 GPa. In order to characterize its high-pressure behavior, we have combined Raman and optical-absorption measurements with density functional theory calculations. We have found evidence of a pressure-induced phase transition near 15 GPa. Experiments and calculations agree in assigning the high-pressure phase to a monoclinic fergusonite-type structure. The reported results are consistent with previous powder x-ray-diffraction experiments, but are in contradiction with the conclusions obtained from earlier Raman measurements, which support the existence of more than one phase transition in the pressure range covered by our studies. The observed scheelite-fergusonite transition induces significant changes in the electronic band gap and phonon spectrum of CaMo O4 . We have determined the pressure evolution of the band gap for the low- and high-pressure phases as well as the frequencies and pressure dependencies of the Raman-active and infrared-active modes. In addition, based on calculations of the phonon dispersion of the scheelite phase, carried out at a pressure higher than the transition pressure, we propose a possible mechanism for the reported phase transition. Furthermore, from the calculations we determined the pressure dependence of the unit-cell parameters and atomic positions of the different phases and their room-temperature equations of state. These results are compared with previous experiments showing a very good agreement. Finally, information on bond compressibility is reported and correlated with the macroscopic compressibility of CaMo O4 . The reported results are of interest for the many technological applications of this oxide.

  19. High-Strength Low-Alloy (HSLA) Mg-Zn-Ca Alloys with Excellent Biodegradation Performance

    Science.gov (United States)

    Hofstetter, J.; Becker, M.; Martinelli, E.; Weinberg, A. M.; Mingler, B.; Kilian, H.; Pogatscher, S.; Uggowitzer, P. J.; Löffler, J. F.

    2014-04-01

    This article deals with the development of fine-grained high-strength low-alloy (HSLA) magnesium alloys intended for use as biodegradable implant material. The alloys contain solely low amounts of Zn and Ca as alloying elements. We illustrate the development path starting from the high-Zn-containing ZX50 (MgZn5Ca0.25) alloy with conventional purity, to an ultrahigh-purity ZX50 modification, and further to the ultrahigh-purity Zn-lean alloy ZX10 (MgZn1Ca0.3). It is shown that alloys with high Zn-content are prone to biocorrosion in various environments, most probably because of the presence of the intermetallic phase Mg6Zn3Ca2. A reduction of the Zn content results in (Mg,Zn)2Ca phase formation. This phase is less noble than the Mg-matrix and therefore, in contrast to Mg6Zn3Ca2, does not act as cathodic site. A fine-grained microstructure is achieved by the controlled formation of fine and homogeneously distributed (Mg,Zn)2Ca precipitates, which influence dynamic recrystallization and grain growth during hot forming. Such design scheme is comparable to that of HSLA steels, where low amounts of alloying elements are intended to produce a very fine dispersion of particles to increase the material's strength by refining the grain size. Consequently our new, ultrapure ZX10 alloy exhibits high strength (yield strength R p = 240 MPa, ultimate tensile strength R m = 255 MPa) and simultaneously high ductility (elongation to fracture A = 27%), as well as low mechanical anisotropy. Because of the anodic nature of the (Mg,Zn)2Ca particles used in the HSLA concept, the in vivo degradation in a rat femur implantation study is very slow and homogeneous without clinically observable hydrogen evolution, making the ZX10 alloy a promising material for biodegradable implants.

  20. Elastic scattering analysis of p + 40Ca at incident energies from threshold to 48.4 MeV and nuclear matter radius

    International Nuclear Information System (INIS)

    Ismail, Atef; Lee, Yen Cheong; Tammam, M.

    2015-01-01

    Proton elastic scattering at various incident energies is one method to study nuclear density distributions and nuclear radii. Single folding potential describing the p-scattering on 40 Ca over a broad energy range 9–48.4 MeV is constructed. The resulting potential does not need any renormalization to fit the measured elastic scattering angular distributions and total reaction cross-sections. Furthermore, correlation between volume integral and proton incident energy is discussed. Theoretical calculations are in a good agreement with existing experimental data. (author)

  1. Influence of extreme pedal rates on pulmonary O(2) uptake kinetics during transitions to high-intensity exercise from an elevated baseline.

    Science.gov (United States)

    Dimenna, Fred J; Wilkerson, Daryl P; Burnley, Mark; Bailey, Stephen J; Jones, Andrew M

    2009-10-31

    We used extreme pedal rates to investigate the influence of muscle fibre recruitment on pulmonary V(O)(2) kinetics during unloaded-to-moderate-intensity (U-->M), unloaded-to-high-intensity (U-->H), and moderate-intensity to high-intensity (M-->H) cycling transitions. Seven healthy men completed transitions to 60% of the difference between gas-exchange threshold and peak V(O)(2) from both an unloaded and a moderate-intensity (95% GET) baseline at cadences of 35 and 115rpm. Pulmonary gas exchange was measured breath-by-breath and iEMG of the m. vastus lateralis and m. gluteus maximus was measured during all tests. At 35rpm, the phase II time constant (tau(p)) values for U-->M, U-->H, and M-->H were 26+/-7, 31+/-7 and 36+/-8s with the value for M-->H being longer than for U-->M (PM, U-->H, and M-->H were 29+/-8, 48+/-16 and 53+/-20s with the value for U-->M being shorter than for the other two conditions (Pinfluenced by an interaction of exercise intensity and pedal rate and are consistent with the notion that changes in muscle fibre recruitment are responsible for slower phase II V(O)(2) kinetics during high-intensity and work-to-work exercise transitions.

  2. High-intensity lower limb endurance training in chronic respiratory disease

    OpenAIRE

    Tanaka, Takako; Arizono, Shinichi; Hanada, Masatoshi; Senjyu, Hideaki

    2015-01-01

    High-intensity endurance training is mainly undertaken during pulmonary rehabilitation for patients with chronic respiratory disease. High-intensity endurance training is recommended in many clinical management guidelines. High-intensity endurance training involves training generally at an intensity of at 60-80% of the patient’s peak work capacity or higher. The effects of high-intensity lower limb endurance training have mostly been investigated in chronic obstructive pulmonary disease (COPD...

  3. Fusion-activated Ca(2+ entry: an "active zone" of elevated Ca(2+ during the postfusion stage of lamellar body exocytosis in rat type II pneumocytes.

    Directory of Open Access Journals (Sweden)

    Pika Miklavc

    2010-06-01

    Full Text Available Ca(2+ is essential for vesicle fusion with the plasma membrane in virtually all types of regulated exocytoses. However, in contrast to the well-known effects of a high cytoplasmic Ca(2+ concentration ([Ca(2+](c in the prefusion phase, the occurrence and significance of Ca(2+ signals in the postfusion phase have not been described before.We studied isolated rat alveolar type II cells using previously developed imaging techniques. These cells release pulmonary surfactant, a complex of lipids and proteins, from secretory vesicles (lamellar bodies in an exceptionally slow, Ca(2+- and actin-dependent process. Measurements of fusion pore formation by darkfield scattered light intensity decrease or FM 1-43 fluorescence intensity increase were combined with analysis of [Ca(2+](c by ratiometric Fura-2 or Fluo-4 fluorescence measurements. We found that the majority of single lamellar body fusion events were followed by a transient (t(1/2 of decay = 3.2 s rise of localized [Ca(2+](c originating at the site of lamellar body fusion. [Ca(2+](c increase followed with a delay of approximately 0.2-0.5 s (method-dependent and in the majority of cases this signal propagated throughout the cell (at approximately 10 microm/s. Removal of Ca(2+ from, or addition of Ni(2+ to the extracellular solution, strongly inhibited these [Ca(2+](c transients, whereas Ca(2+ store depletion with thapsigargin had no effect. Actin-GFP fluorescence around fused LBs increased several seconds after the rise of [Ca(2+](c. Both effects were reduced by the non-specific Ca(2+ channel blocker SKF96365.Fusion-activated Ca(2+entry (FACE is a new mechanism that leads to [Ca(2+](c transients at the site of vesicle fusion. Substantial evidence from this and previous studies indicates that fusion-activated Ca(2+ entry enhances localized surfactant release from type II cells, but it may also play a role for compensatory endocytosis and other cellular functions.

  4. Fusion dynamics in 40Ca induced reactions

    International Nuclear Information System (INIS)

    Prasad, E.; Hinde, D.J.; Williams, E.

    2017-01-01

    Synthesis of superheavy elements (SHEs) and investigation of their properties are among the most challenging research topics in modern science. A non-compound nuclear process called quasi fission is partly responsible for the very low production cross sections of SHEs. The formation and survival probabilities of the compound nucleus (CN) strongly depend on the competition between fusion and quasi fission. A clear understanding of these processes and their dynamics is required to make reliable predictions of the best reactions to synthesise new SHEs. All elements beyond Nh are produced using hot fusion reactions and beams of 48 Ca were used in most of these experiments. In this context a series of fission measurements have been carried out at the Australian National University (ANU) using 40;48 Ca beams on various targets ranging from 142 Nd to 249 Cf. Some of the 40 Ca reactions will be discussed in this symposium

  5. Origins of mass-dependent and mass-independent Ca isotope variations in meteoritic components and meteorites

    Science.gov (United States)

    Bermingham, K. R.; Gussone, N.; Mezger, K.; Krause, J.

    2018-04-01

    The Ca isotope composition of meteorites and their components may vary due to mass-dependent and/or -independent isotope effects. In order to evaluate the origin of these effects, five amoeboid olivine aggregates (AOAs), three calcium aluminum inclusions (CAIs), five chondrules (C), a dark inclusion from Allende (CV3), two dark fragments from North West Africa 753 (NWA 753; R3.9), and a whole rock sample of Orgueil (CI1) were analyzed. This is the first coupled mass-dependent and -independent Ca isotope dataset to include AOAs, a dark inclusion, and dark fragments. Where sample masses permit, Ca isotope data are reported with corresponding petrographic analyses and rare earth element (REE) relative abundance patterns. The CAIs and AOAs are enriched in light Ca isotopes (δ44/40Ca -5.32 to +0.72, where δ44/40Ca is reported relative to SRM 915a). Samples CAI 5 and AOA 1 have anomalous Group II REE patterns. These REE and δ44/40Ca data suggest that the CAI 5 and AOA 1 compositions were set via kinetic isotope fractionation during condensation and evaporation. The remaining samples show mass-dependent Ca isotope variations which cluster between δ44/40Ca +0.53 and +1.59, some of which are coupled with unfractionated REE abundance patterns. These meteoritic components likely formed through the coaccretion of the evaporative residue and condensate following Group II CAI formation or their chemical and isotopic signatures were decoupled (e.g., via nebular or parent-body alteration). The whole rock sample of Orgueil has a δ44/40Ca +0.67 ± 0.18 which is in agreement with most published data. Parent-body alteration, terrestrial alteration, and variable sampling of Ca-rich meteoritic components can have an effect on δ44/40Ca compositions in whole rock meteorites. Samples AOA 1, CAI 5, C 2, and C 4 display mass-independent 48/44Ca anomalies (ε48/44Ca +6 to +12) which are resolved from the standard composition. Other samples measured for these effects (AOA 5, CAI 1, CAI 2

  6. Cuscuta reflexa invasion induces Ca release in its host.

    Science.gov (United States)

    Albert, M; van der Krol, S; Kaldenhoff, R

    2010-05-01

    Cuscuta reflexa induces a variety of reaction in its hosts. Some of these are visual reactions, and it is clear that these morphological changes are preceded by events at the molecular level, where signal transduction is one of the early processes. Calcium (Ca(2+)) release is the major second messenger during signal transduction, and we therefore studied Ca(2+) spiking in tomato during infection with C. reflexa. Bioluminescence in aequorin-expressing tomato was monitored for 48 h after the onset of Cuscuta infestation. Signals at the attachment sites were observed from 30 to 48 h. Treatment of aequorin-expressing tomato leaf disks with Cuscuta plant extracts suggested that the substance that induced Ca(2+) release from the host was closely linked to parasite haustoria.

  7. Mg,Ca-ATPase activity under irradiation

    International Nuclear Information System (INIS)

    Ladutin, V.V.; Orlova, V.V.; Lob, P.A.; Gerasiminko, I.V.; Mack, E.I.

    2003-01-01

    Full text: The influence of different doses irradiation at the Mg,Ca-ATPase activity at the rat brain has been investigated. The analyses were made at the apparatus of LKB and Carl-Ceis-Jena firm with help of reagents of Sigma and Boehringer firm. Rats decapitated after 1, 3, 6, 24 and 48 h after action of irradiation. Dose 0.206 C/kg. Erythrocytes. 1 and 3h after irradiation influence- decrease of Mg,Ca-ATPase activity to 86-87% relatively control level, 24 and 48 h - increase of activity to the control level. Dose 0.312 C/kg. Large hemispheres. 1h - decrease of ATPase activity to 90% relatively control, 3h - increase to control level, 24h - fall to 86%, after 48h small increase to 93% relatively control. Dose 9.287 C/kg. Large hemispheres. 1h - sharp fall of Mg, Ca-ATPase activity to 67 % relatively control, increase of activity to 96% after 3h and sharp fall of activity to 64% 6h after action of irradiation. Dose 9.287 C/kg. Cerebellum. 1h - sharp decrease of ATPase activity to 80%. After 3h -sharp increase to 160% relatively control level and sharp fall of ATPase activity to 47% relatively control after 6h. The mechanism of radiation pathology of active ion transport has been discussed

  8. Low-intensity interval exercise training attenuates coronary vascular dysfunction and preserves Ca²⁺-sensitive K⁺ current in miniature swine with LV hypertrophy.

    Science.gov (United States)

    Emter, Craig A; Tharp, Darla L; Ivey, Jan R; Ganjam, Venkataseshu K; Bowles, Douglas K

    2011-10-01

    Coronary vascular dysfunction has been observed in several models of heart failure (HF). Recent evidence indicates that exercise training is beneficial for patients with HF, but the precise intensity and underlying mechanisms are unknown. Left ventricular (LV) hypertrophy can play a significant role in the development of HF; therefore, the purpose of this study was to assess the effects of low-intensity interval exercise training on coronary vascular function in sedentary (HF) and exercise trained (HF-TR) aortic-banded miniature swine displaying LV hypertrophy. Six months postsurgery, in vivo coronary vascular responses to endothelin-1 (ET-1) and adenosine were measured in the left anterior descending coronary artery. Baseline and maximal coronary vascular conductance were similar between all groups. ET-1-induced reductions in coronary vascular conductance (P < 0.05) were greater in HF vs. sedentary control and HF-TR groups. Pretreatment with the ET type A (ET(A)) receptor blocker BQ-123 prevented ET-1 hypersensitivity in HF animals. Whole cell voltage clamp was used to characterize composite K(+) currents (I(K(+))) in coronary smooth muscle cells. Raising internal Ca(2+) from 200 to 500 nM increased Ca(2+)-sensitive K(+) current in HF-TR and control, but not HF animals. In conclusion, an ET(A)-receptor-mediated hypersensitivity to ET-1, elevated resting LV wall tension, and decreased coronary smooth muscle cell Ca(2+)-sensitive I(K(+)) was found in sedentary animals with LV hypertrophy. Low-intensity interval exercise training preserved normal coronary vascular function and smooth muscle cell Ca(2+)-sensitive I(K(+)), illustrating a potential mechanism underlying coronary vascular dysfunction in a large-animal model of LV hypertrophy. Our results demonstrate the potential clinical impact of exercise on coronary vascular function in HF patients displaying pathological LV hypertrophy.

  9. ELECTRON CLOUD EFFECTS IN HIGH INTENSITY PROTON ACCELERATORS

    International Nuclear Information System (INIS)

    Wei, J.; Macek, R.J.

    2002-01-01

    One of the primary concerns in the design and operation of high-intensity proton synchrotrons and accumulators is the electron cloud and associated beam loss and instabilities. Electron-cloud effects are observed at high-intensity proton machines like the Los Alamos National Laboratory's PSR and CERN's SPS, and investigated experimentally and theoretically. In the design of next-generation high-intensity proton accelerators like the Spallation Neutron Source ring, emphasis is made in minimizing electron production and in enhancing Landau damping. This paper reviews the present understanding of the electron-cloud effects and presents mitigation measures

  10. Synthesis and luminescence properties of glass ceramics containing MSiO3:Eu2+ (M=Ca, Sr, Ba) phosphors for white LED

    International Nuclear Information System (INIS)

    Cui Zhiguang; Jia Guohua; Deng Degang; Hua Youjie; Zhao Shilong; Huang Lihui; Wang Huanping; Ma Hongping; Xu Shiqing

    2012-01-01

    Eu 2+ doped silicate glasses were prepared of the system 52SiO 2 -48MO: xEu 2+ (in molar ratio, M=Ca, Sr, Ba; x=1, 3, 5, 7, 9) by a high temperature melt-quenching method in a reducing atmosphere. Glass ceramics containing MSiO 3 :Eu 2+ (M=Ca, Sr, Ba) nano-phosphors were obtained after the heat treatment of the glass samples. The excitation, emission spectra and lifetime decay curves of 4f 6 5d 1 →4f 7 of Eu 2+ were measured and interpreted with respect to their crystal structures and multi-site occupations of divalent europium in the hosts. Their excitation bands mainly extend from 450 to 250 nm, which is adaptable to the main emission region of the UV LED chip. With UV light excitation, the Eu 2+ emission in CaSiO 3 , SrSiO 3 and BaSiO 3 shows blue, green and yellow colors centered at 440, 505 and 555 nm, respectively. The critical Eu 2+ concentration was studied and determined to be x=5 for both CaSiO 3 and SrSiO 3 and x=7 for BaSiO 3 phosphors. The results show that the Eu 2+ doped glass ceramic phosphors containing MSiO 3 (M=Ca, Sr, Ba) nano-crystals can be used as potential matrix materials for a high power white LED pumped by the UV LED chip. - Highlights: → Glass ceramic containing MSiO 3 :Eu 2+ (M=Ca, Sr, Ba) phosphors prepared. → Derived phosphors emit intensively blue, green and yellow colors. → Their luminescence properties and crystal structures have been investigated. → Concentration quenching effects observed and analyzed. → Potential application for UV chip exciting white LED evaluated.

  11. Dynamic immobilization of simulated radionuclide 133Cs in soil by thermal treatment/vitrification with nanometallic Ca/CaO composites

    International Nuclear Information System (INIS)

    Mallampati, Srinivasa Reddy; Mitoma, Yoshiharu; Okuda, Tetsuji; Simion, Cristian; Lee, Byeong Kyu

    2015-01-01

    Although direct radiation induced health impacts were considered benign, soil contamination with 137 Cs, due to its long-term radiological impact (30 years half-life) and its high biological availability is of a major concern in Japan in the aftermath of the Fukushima nuclear power plant disaster. Therefore 137 Cs reduction and immobilization in contaminated soil are recognized as important problems to be solved using suitable and effective technologies. One such thermal treatment/vitrification with nanometallic Ca/CaO amendments is a promising treatment for the ultimate immobilization of simulated radionuclide 133 Cs in soil, showing low leachability and zero evaporation. Immobilization efficiencies were 88%, 95% and 96% when the 133 Cs soil was treated at 1200 °C with activated carbon, fly ash and nanometallic Ca/CaO additives. In addition, the combination of nanometallic Ca/CaO and fly ash (1:1) enhanced the immobilization efficiency to 99%, while no evaporation of 133 Cs was observed. At lower temperatures (800 °C) the leachable fraction of Cs was only 6% (94% immobilization). Through the SEM–EDS analysis, decrease in the amount of Cs mass percent detectable on soil particle surface was observed after soil vitrified with nCa/CaO + FA. The 133 Cs soil was subjected to vitrified with nCa/CaO + FA peaks related to Ca, crystalline phases (CaCO 3 /Ca(OH) 2 ), wollastonite, pollucite and hematite appeared in addition to quartz, kaolinite and bentonite, which probably indicates that the main fraction of enclosed/bound materials includes Ca-associated complexes. Thus, the thermal treatment with the addition of nanometallic Ca/CaO and fly ash may be considered potentially applicable for the remediation of radioactive Cs contaminated soil at zero evaporation, relatively at low temperature. - Graphical abstract: SEM–EDS element maps of 133 Cs contaminated soil before and after thermal treatment at 1200 °C with different addictives. Color intensity for Cs is from 0

  12. Fine Tuning of CaV1.3 Ca2+ channel properties in adult inner hair cells positioned in the most sensitive region of the Gerbil Cochlea.

    Directory of Open Access Journals (Sweden)

    Valeria Zampini

    Full Text Available Hearing relies on faithful signal transmission by cochlear inner hair cells (IHCs onto auditory fibres over a wide frequency and intensity range. Exocytosis at IHC ribbon synapses is triggered by Ca(2+ inflow through Ca(V1.3 (L-type Ca(2+ channels. We investigated the macroscopic (whole-cell and elementary (cell-attached properties of Ca(2+ currents in IHCs positioned at the middle turn (frequency ∼ 2 kHz of the adult gerbil cochlea, which is their most sensitive hearing region. Using near physiological recordings conditions (body temperature and a Na(+ based extracellular solution, we found that the macroscopic Ca(2+ current activates and deactivates very rapidly (time constant below 1 ms and inactivates slowly and only partially. Single-channel recordings showed an elementary conductance of 15 pS, a sub-ms latency to first opening, and a very low steady-state open probability (Po: 0.024 in response to 500-ms depolarizing steps at ∼-18 mV. The value of Po was significantly larger (0.06 in the first 40 ms of membrane depolarization, which corresponds to the time when most Ca(2+ channel openings occurred clustered in bursts (mean burst duration: 19 ms. Both the Po and the mean burst duration were smaller than those previously reported in high-frequency basal IHCs. Finally, we found that middle turn IHCs are likely to express about 4 times more Ca(2+ channels per ribbon than basal cells. We propose that middle-turn IHCs finely-tune Ca(V1.3 Ca(2+ channel gating in order to provide reliable information upon timing and intensity of lower-frequency sounds.

  13. Fine Tuning of CaV1.3 Ca2+ channel properties in adult inner hair cells positioned in the most sensitive region of the Gerbil Cochlea.

    Science.gov (United States)

    Zampini, Valeria; Johnson, Stuart L; Franz, Christoph; Knipper, Marlies; Holley, Matthew C; Magistretti, Jacopo; Russo, Giancarlo; Marcotti, Walter; Masetto, Sergio

    2014-01-01

    Hearing relies on faithful signal transmission by cochlear inner hair cells (IHCs) onto auditory fibres over a wide frequency and intensity range. Exocytosis at IHC ribbon synapses is triggered by Ca(2+) inflow through Ca(V)1.3 (L-type) Ca(2+) channels. We investigated the macroscopic (whole-cell) and elementary (cell-attached) properties of Ca(2+) currents in IHCs positioned at the middle turn (frequency ∼ 2 kHz) of the adult gerbil cochlea, which is their most sensitive hearing region. Using near physiological recordings conditions (body temperature and a Na(+) based extracellular solution), we found that the macroscopic Ca(2+) current activates and deactivates very rapidly (time constant below 1 ms) and inactivates slowly and only partially. Single-channel recordings showed an elementary conductance of 15 pS, a sub-ms latency to first opening, and a very low steady-state open probability (Po: 0.024 in response to 500-ms depolarizing steps at ∼-18 mV). The value of Po was significantly larger (0.06) in the first 40 ms of membrane depolarization, which corresponds to the time when most Ca(2+) channel openings occurred clustered in bursts (mean burst duration: 19 ms). Both the Po and the mean burst duration were smaller than those previously reported in high-frequency basal IHCs. Finally, we found that middle turn IHCs are likely to express about 4 times more Ca(2+) channels per ribbon than basal cells. We propose that middle-turn IHCs finely-tune Ca(V)1.3 Ca(2+) channel gating in order to provide reliable information upon timing and intensity of lower-frequency sounds.

  14. ELECTRON CLOUD EFFECTS IN HIGH INTENSITY PROTON ACCELERATORS.

    Energy Technology Data Exchange (ETDEWEB)

    WEI,J.; MACEK,R.J.

    2002-04-14

    One of the primary concerns in the design and operation of high-intensity proton synchrotrons and accumulators is the electron cloud and associated beam loss and instabilities. Electron-cloud effects are observed at high-intensity proton machines like the Los Alamos National Laboratory's PSR and CERN's SPS, and investigated experimentally and theoretically. In the design of next-generation high-intensity proton accelerators like the Spallation Neutron Source ring, emphasis is made in minimizing electron production and in enhancing Landau damping. This paper reviews the present understanding of the electron-cloud effects and presents mitigation measures.

  15. Development of high intensity proton accelerator

    International Nuclear Information System (INIS)

    Mizumoto, M.; Kusano, J.; Hasegawa, K.; Ouchi, N.; Oguri, H.; Kinsho, M.; Touchi, Y.; Honda, Y.; Mukugi, K.; Ino, H.; Noda, F.; Akaoka, N.; Kaneko, H.; Chishiro, E.; Fechner, B.

    1997-01-01

    The high-intensity proton linear accelerator with an energy of 1.5 GeV and an average current of 5.33mA has been proposed for the Neutron Science Project (NSP) at JAERI. the NSP is aiming at exploring nuclear technologies for nuclear waste transmutation based on a proton induced spallation neutrons. The proposed accelerators facilities will be also used in the various basic research fields such as condensed matter physics in combination with a high intensity proton storage ring. The R and D work has been carried out for the components of the front-end of the proton accelerator. For the high energy portion above 100 MeV, superconducting (SC) accelerator linac has been designed and developed as a major option. (Author) 7 refs

  16. Locomotor Muscle Fatigue Does Not Alter Oxygen Uptake Kinetics during High-Intensity Exercise.

    Science.gov (United States)

    Hopker, James G; Caporaso, Giuseppe; Azzalin, Andrea; Carpenter, Roger; Marcora, Samuele M

    2016-01-01

    The [Formula: see text] slow component ([Formula: see text]) that develops during high-intensity aerobic exercise is thought to be strongly associated with locomotor muscle fatigue. We sought to experimentally test this hypothesis by pre-fatiguing the locomotor muscles used during subsequent high-intensity cycling exercise. Over two separate visits, eight healthy male participants were asked to either perform a non-metabolically stressful 100 intermittent drop-jumps protocol (pre-fatigue condition) or rest for 33 min (control condition) according to a random and counterbalanced order. Locomotor muscle fatigue was quantified with 6-s maximal sprints at a fixed pedaling cadence of 90 rev·min -1 . Oxygen kinetics and other responses (heart rate, capillary blood lactate concentration and rating of perceived exertion, RPE) were measured during two subsequent bouts of 6 min cycling exercise at 50% of the delta between the lactate threshold and [Formula: see text] determined during a preliminary incremental exercise test. All tests were performed on the same cycle ergometer. Despite significant locomotor muscle fatigue ( P = 0.03), the [Formula: see text] was not significantly different between the pre-fatigue (464 ± 301 mL·min -1 ) and the control (556 ± 223 mL·min -1 ) condition ( P = 0.50). Blood lactate response was not significantly different between conditions ( P = 0.48) but RPE was significantly higher following the pre-fatiguing exercise protocol compared with the control condition ( P locomotor muscle fatigue does not significantly alter the [Formula: see text] kinetic response to high intensity aerobic exercise, and challenge the hypothesis that the [Formula: see text] is strongly associated with locomotor muscle fatigue.

  17. Locomotor muscle fatigue does not alter oxygen uptake kinetics during high-intensity exercise

    Directory of Open Access Journals (Sweden)

    James Hopker

    2016-10-01

    Full Text Available The slow component (VO2sc that develops during high-intensity aerobic exercise is thought to be strongly associated with locomotor muscle fatigue. We sought to experimentally test this hypothesis by pre-fatiguing the locomotor muscles used during subsequent high-intensity cycling exercise. Over two separate visits, eight healthy male participants were asked to either perform a non-metabolically stressful 100 intermittent drop-jumps protocol (pre fatigue condition or rest for 33 minutes (control condition according to a random and counterbalanced order. Locomotor muscle fatigue was quantified with 6-second maximal sprints at a fixed pedaling cadence of 90 rev·min-1. Oxygen kinetics and other responses (heart rate, capillary blood lactate concentration and rating of perceived exertion, RPE were measured during two subsequent bouts of 6 min cycling exercise at 50% of the delta between the lactate threshold and VO2max determined during a preliminary incremental exercise test. All tests were performed on the same cycle ergometer. Despite significant locomotor muscle fatigue (P = 0.03, the VO2sc was not significantly different between the pre fatigue (464 ± 301 mL·min-1 and the control (556 ± 223 mL·min-1 condition (P = 0.50. Blood lactate response was not significantly different between conditions (P = 0.48 but RPE was significantly higher following the pre-fatiguing exercise protocol compared with the control condition (P < 0.01 suggesting higher muscle recruitment. These results demonstrate experimentally that locomotor muscle fatigue does not significantly alter the VO2 kinetic response to high intensity aerobic exercise, and challenge the hypothesis that the VO2sc is strongly associated with locomotor muscle fatigue.

  18. SALIVARY CORTISOL RESPONSES AND PERCEIVED EXERTION DURING HIGH INTENSITY AND LOW INTENSITY BOUTS OF RESISTANCE EXERCISE

    Directory of Open Access Journals (Sweden)

    Alison D. Egan

    2004-03-01

    Full Text Available The purpose of this study was to measure the salivary cortisol response to different intensities of resistance exercise. In addition, we wanted to determine the reliability of the session rating of perceived exertion (RPE scale to monitor resistance exercise intensity. Subjects (8 men, 9 women completed 2 trials of acute resistance training bouts in a counterbalanced design. The high intensity resistance exercise protocol consisted of six, ten-repetition sets using 75% of one repetition maximum (RM on a Smith machine squat and bench press exercise (12 sets total. The low intensity resistance exercise protocol consisted of three, ten-repetition sets at 30% of 1RM of the same exercises as the high intensity protocol. Both exercise bouts were performed with 2 minutes of rest between each exercise and sessions were repeated to test reliability of the measures. The order of the exercise bouts was randomized with least 72 hours between each session. Saliva samples were obtained immediately before, immediately after and 30 mins following each resistance exercise bout. RPE measures were obtained using Borg's CR-10 scale following each set. Also, the session RPE for the entire exercise session was obtained 30 minutes following completion of the session. There was a significant 97% increase in the level of salivary cortisol immediately following the high intensity exercise session (P<0.05. There was also a significant difference in salivary cortisol of 145% between the low intensity and high intensity exercise session immediately post-exercise (P<0.05. The low intensity exercise did not result in any significant changes in cortisol levels. There was also a significant difference between the session RPE values for the different intensity levels (high intensity 7.1 vs. low intensity 1.9 (P<0.05. The intraclass correlation coefficient for the session RPE measure was 0.95. It was concluded that the session RPE method is a valid and reliable method of

  19. Large piezoelectric strain with ultra-low strain hysteresis in highly c-axis oriented Pb(Zr0.52Ti0.48)O3 films with columnar growth on amorphous glass substrates

    NARCIS (Netherlands)

    Nguyen, Minh D.; Houwman, Evert P.; Rijnders, Guus

    2017-01-01

    Thin films of PbZr0.52Ti0.48O3 (PZT) with largely detached columnar grains, deposited by pulsed laser deposition (PLD) on amorphous glass substrates covered with Ca2Nb3O10 nanosheets as growth template and using LaNiO3 electrode layers, are shown to exhibit very high unipolar piezoelectric strain

  20. Benefits of High-Intensity Intensive Care Unit Physician Staffing under the Affordable Care Act

    Directory of Open Access Journals (Sweden)

    Sachin Logani

    2011-01-01

    Full Text Available The Affordable Care Act signed into law by President Obama, with its value-based purchasing program, is designed to link payment to quality processes and outcomes. Treatment of critically ill patients represents nearly 1% of the gross domestic product and 25% of a typical hospital budget. Data suggest that high-intensity staffing patterns in the intensive care unit (ICU are associated with cost savings and improved outcomes. We evaluate the literature investigating the cost-effectiveness and clinical outcomes of high-intensity ICU physician staffing as recommended by The Leapfrog Group (a consortium of companies that purchase health care for their employees and identify ways to overcome barriers to nationwide implementation of these standards. Hospitals that have implemented the Leapfrog initiative have demonstrated reductions in mortality and length of stay and increased cost savings. High-intensity staffing models appear to be an immediate cost-effective way for hospitals to meet the challenges of health care reform.

  1. The 4.8 hour variation of Cygnus X-3 at high X-ray energies

    International Nuclear Information System (INIS)

    Pietsch, W.; Kendziorra, E.; Staubert, R.; Trumper, J.

    1976-01-01

    During a balloon observation of Cygnus X-3 on 1975 February 20, an intensity variation has been found which is in phase with the low-energy X-ray 4.8 hour sinusoidal light curve. The measured relative amplitude in the range 32--64 keV is 0.37 (+0.31, -0.29). Compared with the results at lower energies there is no indication for an energy dependence of the relative amplitude up to 64 keV. The encountered low-intensity source spectrum is compared with previous measurements

  2. Hydralazine-induced vasodilation involves opening of high conductance Ca2+-activated K+ channels

    DEFF Research Database (Denmark)

    Bang, Lone; Nielsen-Kudsk, J E; Gruhn, N

    1998-01-01

    The purpose of this study was to investigate whether high conductance Ca2+-activated K+ channels (BK(Ca)) are mediating the vasodilator action of hydralazine. In isolated porcine coronary arteries, hydralazine (1-300 microM), like the K+ channel opener levcromakalim, preferentially relaxed......M) suppressed this response by 82% (P opening of BK(Ca) takes part in the mechanism whereby...

  3. Measurement of cytoplasmic Ca2+ concentration in Saccharomyces cerevisiae induced by air cold plasma

    Science.gov (United States)

    Xiaoyu, DONG

    2018-03-01

    In this study, a novel approach to measure the absolute cytoplasmic Ca2+ concentration ([Ca2+]cyt) using the Ca2+ indicator fluo-3 AM was established. The parameters associated with the probe fluo-3 AM were optimized to accurately determine fluorescence intensity from the Ca2+-bound probe. Using three optimized parameters (final concentration of 6 mM probe, incubation time of 135 min, loading probe before plasma treatment), the maximum fluorescence intensity (F max = 527.8 a.u.) and the minimum fluorescence intensity (F min = 63.8 a.u.) were obtained in a saturated Ca2+ solution or a solution of lacking Ca2+. Correspondingly, the maximum [Ca2+]cyt induced by cold plasma was 1232.5 nM. Therefore, the Ca2+ indicator fluo-3 AM was successfully applied to measure the absolute [Ca2+]cyt in Saccharomyces cerevisiae stimulated by cold plasma at atmospheric air pressure.

  4. Earthworm assemblages in different intensity of agricultural uses and their relation to edaphic variables

    Directory of Open Access Journals (Sweden)

    LB Falco

    2015-05-01

    Full Text Available The objective of this study was to relate earthworm assemblage structure with three different soil use intensities, and to indentify the physical, chemical, and microbiological soil variables that are associated to the observed differences. Three soil uses were evaluated: 1-Fifty year old naturalized grasslands, low use intensity; 2-Recent agricultural fields, intermediate use intensity, and 3-Fifty year old intensive agricultural fields, high use intensity. Three different sites for each soil use were evaluated from winter 2008 through summer 2011. Nine earthworm species were identified across all sampling sites. The sites shared five species: the native Microscolex dubius, and the introduced Aporrectodea caliginosa, A. rosea, Octalasion cyaneum, and O. lacteum, but they differed in relative abundance by soil use. The results show that the earthworm community structure is linked to and modulated by soil properties. Both species abundance and diversity showed significant differences depending on soil use intensity. A principal component analysis showed that species composition is closely related to the environmental variability. The ratio of native to exotic species was significantly lower in the intensive agricultural system when compared to the other two, lower disturbance systems. Microscolex dubius abundance was related to naturalized grasslands along with soil Ca, pH, mechanical resistance, and microbial respiration. Aporrectodea caliginosa abundance was related to high K levels, low enzymatic activity, slightly low pH, low Ca, and appeared related to the highly disturbed environment. Eukerria stagnalis and Aporrectodea rosea, commonly found in the recent agricultural system, were related to high soil moisture condition, low pH, low Ca and low enzymatic activity. These results show that earthworm assemblages can be good indicators of soil use intensities. In particular, Microscolex dubius, Aporrectodea caliginosa, and Aporrectodea rosea

  5. High-intensity interval training evokes larger serum BDNF levels compared with intense continuous exercise.

    Science.gov (United States)

    Saucedo Marquez, Cinthia Maria; Vanaudenaerde, Bart; Troosters, Thierry; Wenderoth, Nicole

    2015-12-15

    Exercise can have a positive effect on the brain by activating brain-derived neurotrophic factor (BDNF)-related processes. In healthy humans there appears to be a linear relationship between exercise intensity and the positive short-term effect of acute exercise on BDNF levels (i.e., the highest BDNF levels are reported after high-intensity exercise protocols). Here we performed two experiments to test the effectiveness of two high-intensity exercise protocols, both known to improve cardiovascular health, to determine whether they have a similar efficacy in affecting BDNF levels. Participants performed a continuous exercise (CON) protocol at 70% of maximal work rate and a high-intensity interval-training (HIT) protocol at 90% of maximal work rate for periods of 1 min alternating with 1 min of rest (both protocols lasted 20 min). We observed similar BDNF kinetics in both protocols, with maximal BDNF concentrations being reached toward the end of training (experiment 1). We then showed that both exercise protocols significantly increase BDNF levels compared with a rest condition (CON P = 0.04; HIT P exercise are slightly more effective than continuous high-intensity exercise for elevating serum BDNF. Additionally, 73% of the participants preferred the HIT protocol (P = 0.02). Therefore, we suggest that the HIT protocol might represent an effective and preferred intervention for elevating BDNF levels and potentially promoting brain health. Copyright © 2015 the American Physiological Society.

  6. Light-intensity and high-intensity interval training improve cardiometabolic health in rats.

    Science.gov (United States)

    Batacan, Romeo B; Duncan, Mitch J; Dalbo, Vincent J; Connolly, Kylie J; Fenning, Andrew S

    2016-09-01

    Physical activity has the potential to reduce cardiometabolic risk factors but evaluation of different intensities of physical activity and the mechanisms behind their health effects still need to be fully established. This study examined the effects of sedentary behaviour, light-intensity training, and high-intensity interval training on biometric indices, glucose and lipid metabolism, inflammatory and oxidative stress markers, and vascular and cardiac function in adult rats. Rats (12 weeks old) were randomly assigned to 1 of 4 groups: control (CTL; no exercise), sedentary (SED; no exercise and housed in small cages to reduce activity), light-intensity trained (LIT; four 30-min exercise bouts/day at 8 m/min separated by 2-h rest period, 5 days/week), and high-intensity interval trained (HIIT, four 2.5-min work bouts/day at 50 m/min separated by 3-min rest periods, 5 days/week). After 12 weeks of intervention, SED had greater visceral fat accumulation (p HIIT demonstrated beneficial changes in body weight, visceral and epididymal fat weight, glucose regulation, low-density lipoprotein cholesterol, total cholesterol, and mesenteric vessel contractile response compared with the CTL group (p HIIT had significant improvements in systolic blood pressure and endothelium-independent vasodilation to aorta and mesenteric artery compared with the CTL group (p HIIT induce health benefits by improving traditional cardiometabolic risk factors. LIT improves cardiac health while HIIT promotes improvements in vascular health.

  7. CaCO3-III and CaCO3-VI, high-pressure polymorphs of calcite: Possible host structures for carbon in the Earth's mantle

    Science.gov (United States)

    Merlini, M.; Hanfland, M.; Crichton, W. A.

    2012-06-01

    Calcite, CaCO3, undergoes several high pressure phase transitions. We report here the crystal structure determination of the CaCO3-III and CaCO3-VI high-pressure polymorphs obtained by single-crystal synchrotron X-ray diffraction. This new technical development at synchrotron beamlines currently affords the possibility of collecting single-crystal data suitable for structure determination in-situ at non-ambient conditions, even after multiphase transitions. CaCO3-III, observed in the pressure range 2.5-15 GPa, is triclinic, and it presents two closely related structural modifications, one, CaCO3-III, with 50 atoms in the unit cell [a=6.281(1) Å, b=7.507(2) Å, c=12.516(3) Å, α=93.76(2)°, β=98.95(2)°, γ=106.49(2)°, V=555.26(20) Å3 at 2.8 GPa], the second, CaCO3-IIIb, with 20 atoms [a=6.144(3) Å, b=6.3715(14) Å, c=6.3759(15) Å, α= 93.84(2)°, β=107.34(3)°, γ=107.16(3)°, V=224.33(13) Å3 at 3.1 GPa]. Different pressure-time experimental paths can stabilise one or the other polymorph. Both structures are characterised by the presence of non-coplanar CO3 groups. The densities of CaCO3-III (2.99 g/cm3 at 2.8 GPa) and CaCO3-IIIb (2.96 g/cm3 at 3.1 GPa) are lower than aragonite, in agreement with the currently accepted view of aragonite as the thermodynamically stable Ca-carbonate phase at these pressures. The presence of different cation sites, with variable volume and coordination number (7-9), suggests however that these structures have the potential to accommodate cations with different sizes without introducing major structural strain. Indeed, this structure can be adopted by natural Ca-rich carbonates, which often exhibit compositions deviating from pure calcite. Mg-calcites are found both in nature (Frezzotti et al., 2011) and in experimental syntheses at conditions corresponding to deep subduction environments (Poli et al., 2009). At these conditions, the low pressure rhombohedral calcite structure is most unlikely to be stable, and, at the same

  8. Very high intensity reaction chamber design

    International Nuclear Information System (INIS)

    Devaney, J.J.

    1975-09-01

    The problem of achieving very high intensity irradiation by light in minimal regions was studied. Three types of irradiation chamber are suggested: the common laser-reaction chamber, the folded concentric or near-concentric resonator, and the asymmetric confocal resonator. In all designs the ratio of high-intensity illuminated volume to other volume is highly dependent (to the 3 / 2 power) on the power and fluence tolerances of optical elements, primarily mirrors. Optimization of energy coupling is discussed for the common cavity. For the concentric cavities, optimization for both coherent and incoherent beams is treated. Formulae and numerical examples give the size of chambers, aspect ratios, maximum pass number, image sizes, fluences, and the like. Similarly for the asymmetric confocal chamber, formulae and numerical examples for fluences, dimensions, losses, and totally contained pass numbers are given

  9. Basic and clinical evaluation of CA 130 RIA kit (D-7111) using two newly developed monoclonal antibodies. Comparison with CA 125 kit

    Energy Technology Data Exchange (ETDEWEB)

    Saga, Tsuneo; Endo, Keigo; Nakajima, Tetsuo and others

    1988-10-01

    The CA 130 RIA kit was developed with the use of two monoclonal antibodies, 130 - 22 and 145 - 9. Laboratory performance was satisfactory for precision, reproducibility, recovery, and dilution. Measurement values with CA 130 kit were almost consistent with those with CA 125 kit. Favorable standard curves were attained with smaller concentrations and shorter incubation time of CA 130 kit than those with CA 125 kit. There was less prozone phenomenon. When defining a cut-off serum level of CA 130 as 35 U/ml, false-positive rate was 0 % for healthy men and 4 % for healthy women, suggesting the involvement of menstrual cycle. Positive rate for CA 130 was 65 % for malignant ovarian tumor, 48 % for lung cancer, and 47 % for endometriosis. (Namekawa, K.).

  10. Apparatus for controlled mixing in a high intensity mixer

    International Nuclear Information System (INIS)

    Crocker, Z.; Gupta, V.P.

    1982-01-01

    An apparatus and a process is disclosed for controlled mixing of a mixable material in a high intensity mixer. The system enables instantaneous, precise and continual monitoring of a batch in a high intensity mixer which heretofore could not be achieved. The process comprises the steps of feeding a batch of material into a high intensity mixer, agitating the batch in the mixer, monitoring batch temperature separately from mixer temperature and discharging the batch from the mixer when the batch temperature reaches a final predetermined level. The apparatus includes means for monitoring batch temperature in a high intensity mixer separately from mixer temperature, and means responsive to the batch temperature to discharge the batch when the batch temperature reaches a final predetermined level

  11. Reduced endogenous Ca2+ buffering speeds active zone Ca2+ signaling.

    Science.gov (United States)

    Delvendahl, Igor; Jablonski, Lukasz; Baade, Carolin; Matveev, Victor; Neher, Erwin; Hallermann, Stefan

    2015-06-09

    Fast synchronous neurotransmitter release at the presynaptic active zone is triggered by local Ca(2+) signals, which are confined in their spatiotemporal extent by endogenous Ca(2+) buffers. However, it remains elusive how rapid and reliable Ca(2+) signaling can be sustained during repetitive release. Here, we established quantitative two-photon Ca(2+) imaging in cerebellar mossy fiber boutons, which fire at exceptionally high rates. We show that endogenous fixed buffers have a surprisingly low Ca(2+)-binding ratio (∼ 15) and low affinity, whereas mobile buffers have high affinity. Experimentally constrained modeling revealed that the low endogenous buffering promotes fast clearance of Ca(2+) from the active zone during repetitive firing. Measuring Ca(2+) signals at different distances from active zones with ultra-high-resolution confirmed our model predictions. Our results lead to the concept that reduced Ca(2+) buffering enables fast active zone Ca(2+) signaling, suggesting that the strength of endogenous Ca(2+) buffering limits the rate of synchronous synaptic transmission.

  12. Radioisotope 45Ca labeling four calcium chemical compounds and tracing calcium bioavailability

    International Nuclear Information System (INIS)

    Zheng Hui; Zhen Rong; Niu Huisheng; Li Huaifen

    2004-01-01

    Objective: To build up a new method of the radioisotope 45 Ca labeling four calcium chemical compounds, observe and tracing bioavailability change of calcium labeled with radioisotope 45 Ca. Methods: The calcium gluconate (Ca-Glu), calcium citrate (Ca-Cit), calcium carbonate (Ca-Car) and calcium L-threonate (Ca-Thr)were labeled by radioisotope 45 Ca. Four calcium chemical compounds of 45 Ca labeling were used of calcium content 200 mg/kg in the rats and measure the absorption content and bioavailability of calcium in tissue of heart, lever spleen, stomach, kidney, brain, intestine, whole blood, urine, faeces. Results: 1) Radioisotope 45 Ca labeling calcium chemical compound has high radio intensity, more steady standard curve and recover rate. 2) The absorption of organic calcium chemical compounds is higher than the inorganic calcium chemical compound in the study of calcium bioavailability. Conclusion: The method of tracing with radioisotope 45 Ca labeling calcium chemical compounds has the characteristic of the sensitive, objective, accurate and steady in the study of calcium bioavailability

  13. Whole-Body High-Intensity Interval Training Induce Similar Cardiorespiratory Adaptations Compared With Traditional High-Intensity Interval Training and Moderate-Intensity Continuous Training in Healthy Men.

    Science.gov (United States)

    Schaun, Gustavo Z; Pinto, Stephanie S; Silva, Mariana R; Dolinski, Davi B; Alberton, Cristine L

    2018-05-07

    Schaun, GZ, Pinto, SS, Silva, MR, Dolinski, DB, and Alberton, CL. Sixteen weeks of whole-body high-intensity interval training induce similar cardiorespiratory responses compared with traditional high-intensity interval training and moderate-intensity continuous training in healthy men. J Strength Cond Res XX(X): 000-000, 2018-Low-volume high-intensity interval training (HIIT) protocols that use the body weight as resistance could be an interesting and inexpensive alternative to traditional ergometer-based high-intensity interval training (HIIT-T) and moderate-intensity continuous training (MICT). Therefore, our aim was to compare the effects of 16 weeks of whole-body HIIT (HIIT-WB), HIIT-T, and MICT on maximal oxygen uptake (V[Combining Dot Above]O2max), second ventilatory threshold (VT2), and running economy (RE) outcomes. Fifty-five healthy men (23.7 ± 0.7 years, 1.79 ± 0.01 m, 78.5 ± 1.7 kg) were randomized into 3 training groups (HIIT-T = 17; HIIT-WB = 19; MICT = 19) for 16 weeks (3× per week). The HIIT-T group performed eight 20-second bouts at 130% of the velocity associated to V[Combining Dot Above]O2max (vV[Combining Dot Above]O2max) interspersed by 10-second passive recovery on a treadmill, whereas HIIT-WB group performed the same protocol but used calisthenics exercises at an all-out intensity instead of treadmill running. Finally, MICT group exercised for 30 minutes at 90-95% of the heart rate (HR) associated to VT2. After the intervention, all groups improved V[Combining Dot Above]O2max, vV[Combining Dot Above]O2max, time to exhaustion (Tmax), VT2, velocity associated with VT2 (vVT2), and time to reach VT2 (tVT2) significantly (p HIIT-T compared with HIIT-WB (p HIIT-WB can be as effective as traditional HIIT while also being time-efficient compared with MICT to improve health-related outcomes after 16 weeks of training. However, HIIT-T and MICT seem preferable to enhance performance-related outcomes compared with HIIT-WB.

  14. High-Intensity Interval Training in Patients with Substance Use Disorder

    Directory of Open Access Journals (Sweden)

    Grete Flemmen

    2014-01-01

    Full Text Available Patients with substance use disorder (SUD suffer a higher risk of cardiovascular disease and other lifestyle diseases compared to the general population. High intensity training has been shown to effectively reduce this risk, and therefore we aimed to examine the feasibility and effect of such training in SUD patients in clinical treatment in the present study. 17 males and 7 females (32 ± 8 yr in treatment were randomized to either a training group (TG, treadmill interval training in 4 × 4 minutes at 90–95% of maximal heart rate, 3 days a week for 8 weeks, or a conventional rehabilitation control group (CG. Baseline values for both groups combined at inclusion were 44 ± 8 (males and 34 ± 9 (females mL · min−1 · kg−1, respectively. 9/12 and 7/12 patients completed the TG and CG, respectively. Only the TG significantly improved (15 ± 7% their maximal oxygen consumption (VO2max, from 42.3 ± 7.2 mL · min−1 · kg−1 at pretest to 48.7 ± 9.2 mL · min−1 · kg−1 at posttest. No between-group differences were observed in work economy, and level of insomnia (ISI or anxiety and depression (HAD, but a significant within-group improvement in depression was apparent for the TG. High intensity training was feasible for SUD patients in treatment. This training form should be implemented as a part of the rehabilitation since it, in contrast to the conventional treatment, represents a risk reduction for cardiovascular disease and premature death.

  15. Highly anisotropic magnon dispersion in Ca{sub 2}RuO{sub 4}. Evidence for strong spin orbit coupling

    Energy Technology Data Exchange (ETDEWEB)

    Kunkemoeller, Stefan; Khomskii, Daniel; Braden, Markus [II. Physikalisches Institut, Universitaet zu Koeln (Germany); Steffens, Paul; Piovano, Andrea [Institut Laue Langevin, Grenoble (France); Nugroho, Augustinus Agung [Institut Teknologi Bandung (Indonesia)

    2016-07-01

    Ca{sub 2}RuO{sub 4} is a key material for the understanding of the impact of spin-orbit coupling in 4d and 5d compounds, which is intensively studied at present. We have studied the magnon dispersion in Ca{sub 2}RuO{sub 4} by inelastic neutron scattering on large single crystals containing 1% of Ti. With this unmagnetic substitution large single crystals could be obtained with the floating zone method. The magnon dispersion can be well described with the simple conventional Heisenberg model. Ca{sub 2}RuO{sub 4} reveals a large anisotropy gap of 13 meV, which shows that spin-orbit coupling and some in-plane orbital ordering are both important parameters for the description of the electronic and magnetic properties of Ca{sub 2}RuO{sub 4}.

  16. Low energy resonance in the neutron rich nucleus of 48Ca. New detectors for the study of unstable nuclei: MUST and CATS

    International Nuclear Information System (INIS)

    Ottini, St.

    1998-01-01

    Two new detectors have been developed to study reactions resulting from exotic beams. The first one, MUST, a set of Si strip detectors is devoted to light recoil particles detection between 500 eV and 120 MeV. The 40 Ar elastic and inelastic scattering analysis at 77 MeV per nucleon showed a non ambiguous identification of the particles in the detector, thanks the time and energy resolutions. The second one, CATs, is a set of beam detectors. These low pressure wire chambers allow each particle measurement of the exotic beams with an accuracy of 0,4 mm. A special interest is given to the halo nuclei low excitation energy spectra. A dipolar low energy resonance should be observed. The inelastic scattering at 60 MeV per nucleon on two targets ( 40 Ca and 48 Ca) has been studied with SPEG at Ganil (France), to search a low energy resonance. It is not possible to conclude on this low energy resonance existence. (A.L.B.)

  17. Early High-Intensity Versus Low-Intensity Rehabilitation After Total Knee Arthroplasty (TKA) by Bade et al

    DEFF Research Database (Denmark)

    Mechlenburg, Inger; Skoffer, Birgit; Dalgas, Ulrik

    2017-01-01

    Recently, a paper entitled "Early High-Intensity Versus Low-Intensity Rehabilitation After Total Knee Arthroplasty: A Randomized Controlled Trial" was published in Arthritis Care Res by Bade et al. (1). We have read the paper with great interest and noted that the study shows essentially no diffe......Recently, a paper entitled "Early High-Intensity Versus Low-Intensity Rehabilitation After Total Knee Arthroplasty: A Randomized Controlled Trial" was published in Arthritis Care Res by Bade et al. (1). We have read the paper with great interest and noted that the study shows essentially...

  18. Case Study on Justification: High Intensity Discharge Lamps. Annex II

    International Nuclear Information System (INIS)

    2016-01-01

    High intensity discharge lamps produce bright white light of a high intensity in an energy efficient manner. These lamps are typically used in large numbers in public and professional settings such as shops, warehouses, hotels and offices. They are also used in outdoor applications to illuminate streets, buildings, statues, flags and gardens and further as architectural lighting. They also have applications associated with film projection in cinemas, manufacture of semiconductors, fluorescence endoscopy and microscopy, schlieren photography, hologram projection, ultraviolet curing, sky beamers and car headlights. Some types of high intensity discharge lamp, as well as certain other consumer products for lighting, contain radioactive substances for functional reasons. The radionuclides that are typically incorporated into high intensity discharge lamps are 85 Kr and 232 Th. Given the wide range of uses, specific decisions on justification may be required for different applications. A small number of safety assessments for high intensity discharge lamps have been carried out and published. No published decisions at the national level specifically addressing the justification of the use of high intensity discharge lamps have been identified

  19. Crystal Structures and Mechanical Properties of Ca2C at High Pressure

    Directory of Open Access Journals (Sweden)

    Qun Wei

    2016-07-01

    Full Text Available Recently, a new high-pressure semiconductor phase of Ca2C (space group Pnma was successfully synthesized, it has a low-pressure metallic phase (space group C2/m. In this paper, a systematic investigation of the pressure-induced phase transition of Ca2C is studied on the basis of first-principles calculations. The calculated enthalpy reveals that the phase transition which transforms from C2/m-Ca2C to Pnma-Ca2C occurs at 7.8 GPa, and it is a first-order phase transition with a volume drop of 26.7%. The calculated elastic constants show that C2/m-Ca2C is mechanically unstable above 6.4 GPa, indicating that the structural phase transition is due to mechanical instability. Both of the two phases exhibit the elastic anisotropy. The semiconductivity of Pnma-Ca2C and the metallicity of C2/m-Ca2C have been demonstrated by the electronic band structure calculations. The quasi-direct band gap of Pnma-Ca2C at 0 GPa is 0.86 eV. Furthermore, the detailed analysis of the total and partial density of states is performed to show the specific contribution to the Fermi level.

  20. The value of clinical expression of CA series in malignancy diagnosis

    International Nuclear Information System (INIS)

    Wei Zhenyuan; Wang Jie

    2002-01-01

    Objective: To study the diagnosis of liver cancer, coloprocto-carcinoma, ovary cancer, pancreatic carcinoma, breast cancer, lung cancer and stomach cancer by labelling immunoassay of CA50, CA125, CA199 and CA153. Methods: The authors had measured the serum content of these tumor markers in 67 liver cancer, 88 coloprocto-carcinoma, 48 ovary cancer, 36 pancreatic carcinoma, 34 breast cancer, 128 lung cancer, 271 stomach cancer and 68 normal controls with labelling immunoassay (LIA). The mean coefficient of variation for intra and inter batch-assay of CA50, CA125, CA199 and CA153 were 3.7% and 8.1%, 4.8% and 10.1%, 7.6% and 12.3%, 8.1% and 10.4% respectively. The average recovery ratio was between 95% and 107%. Results: The levels of CA50 in stomach cancer and coloprocto-carcinoma were significantly higher than those in normal controls (p < 0.001). The levels of CA125 in ovary cancer and lung cancer were significantly higher than in normal controls (p < 0.001). The levels of CA199 in pancreatic carcinoma cancer was significantly higher than those in normal controls (p < 0.001). The levels of CA153 in breast cancer was significantly higher than those in normal controls (p < 0.001). The mean levels of CA50, CA125, CA199 and CA153 in 68 normal controls were 12.4 +- 3.9 U/ml, 14.3 +- 3.9 U/ml, 14.3 +- 10.5 U/ml, 10.0 +- 8.4 U/ml and 15.2 +- 7.5 U/ml respectively. Conclusion: In present study of 672 cases, CA50 measurement seems to be most useful for diagnosis of gastric and coloprocto-carcinoma, CA125 for ovarian cancer, CA199 for pancreatic cancer and CA153 for breast cancer (p < 0.001)

  1. Age-related changes in physical and perceptual markers of recovery following high-intensity interval cycle exercise.

    Science.gov (United States)

    Borges, Nattai R; Reaburn, Peter R; Doering, Thomas M; Argus, Christos K; Driller, Matthew W

    2018-05-29

    The purpose of this study was to compare physical performance, perceptual and haematological markers of recovery in well-trained masters and young cyclists across 48 h following a bout of repeated high-intensity interval exercise. Nine masters (mean ± SD; age = 55.6 ± 5.0 years) and eight young (age = 25.9 ± 3.0 years) cyclists performed a high-intensity interval exercise session consisting of 6 × 30 s intervals at 175% peak power output with 4.5 min rest between efforts. Maximal voluntary contraction (MVC), 10 s sprint (10SST), 30-min time trial (30TT) performance, creatine kinase concentration (CK) and perceptual measures of motivation, total recovery, fatigue and muscle soreness were collected at baseline and at standardised time points across the 48 h recovery period. No significant group-time interactions were observed for performance of MVC, 10SST, 30TT and CK (P > 0.05). A significant reduction in 10SST peak power was found in both masters (P = 0.002) and young (P = 0.003) cyclists at 1 h post exercise, however, both groups physically recovered at similar rates. Neither group showed significant (P > 0.05) or practically meaningful increases in CK (%∆ < 10%). A significant age-related difference was found for perceptual fatigue (P = 0.01) and analysis of effect size (ES) showed that perceptual recovery was delayed with masters cyclists reporting lower motivation (ES ±90%CI = 0.69 ± 0.77, moderate), greater fatigue (ES = 0.75 ± 0.93, moderate) and muscle soreness (ES = 0.61 ± 0.70, moderate) after 48 h of recovery. The delay in perceived recovery may have negative effects on long-term participation to systematic training.

  2. Stimulated Raman backscattering at high laser intensities

    Energy Technology Data Exchange (ETDEWEB)

    Skoric, M M [Vinca Inst. of Nuclear Sciences, Belgrade (Yugoslavia); Tajima, Toshiki; Sasaki, Akira; Maluckov, A; Jovanovic, M

    1998-03-01

    Signatures of Stimulated Raman backscattering of a short-pulse high-intensity laser interacting with an underdense plasma are discussed. We introduce a nonlinear three-wave interaction model that accounts for laser pump depletion and relativistic detuning. A mechanism is revealed based on a generic route to chaos, that predicts a progressive increase of the backscatter complexity with a growing laser intensity. Importance of kinetic effects is outlined and demonstrated in fluid-hybrid and particle simulations. As an application, we show that spectral anomalies of the backscatter, predicted by the above model, are consistent with recent sub-picosecond, high-intensity laser gas-target measurements at Livermore and elsewhere. Finally, a recently proposed scheme for generation of ultra-short, low-prepulse laser pulses by Raman backscattering in a thin foil target, is shown. (author)

  3. The cross section measurement for the reactions of 48,46Ti(n,p) 48,46Sc, 50Ti(n, α)47Ca and 58Ni (n, 2n)57Ni, 58Ni(n,p)58m+gCo

    International Nuclear Information System (INIS)

    Yuan Junqian; Wang Yongchang; Kong Xiangzhong; Yang Jingkang

    1992-01-01

    The cross sections for the 50 Ti(n, α) 47 Ca, 46 Ti(n, p) 46 Sc, 48 Ti(n, p) 48 Sc and 58 Ni(n, 2n) 57 Ni, 58 Ni(n, p) 58m+g Co reactions have been measured by using the activation method relative to the cross sections of the 27 Al(n, α) 24 Na reaction in the neutron energy range of 13.50-14.81 MeV. The neutron energies were determined by the cross section ratios of the 90 Zr(n, 2n) 89m+g Zr and 93 Nb(n, 2n) 92m Nb reactions. The results obtained are compared with the published and to be published data of several authors

  4. Bi--Sr--Ca--Cu--O superconducting films fabricated using metal alkoxides

    International Nuclear Information System (INIS)

    Katayama, S.; Sekine, M.

    1991-01-01

    Superconducting films in the Bi--Sr--Ca--Cu--O systems were made using metal alkoxides. To prepare a dip-coating solution using a mixed alkoxide solution, insoluble Cu and Bi alkoxides were dissolved by modification with 2-dimethylaminoethanol and formation of a double alkoxide, respectively. Formation of the double alkoxides of Bi with Ca or Sr was confirmed using FT-IR and 1 H-NMR. Bi--Sr--Ca--Cu--O films on yttria-stabilized ZrO 2 and single crystal MgO(100) substrates were made using this solution. The films were closely oriented along the c-axis perpendicular to the substrate. The film on MgO(100) fired at 850 degree C for 48 h showed two resistance drops around 115 and 85 K, corresponding to the high-T c and low-T c phases, respectively, and zero resistance at 72 K

  5. Structural Phase Transition and Compressibility of CaF2 Nanocrystals under High Pressure

    Directory of Open Access Journals (Sweden)

    Jingshu Wang

    2018-05-01

    Full Text Available The structural phase transition and compressibility of CaF2 nanocrystals with size of 23 nm under high pressure were investigated by synchrotron X-ray diffraction measurement. A pressure-induced fluorite to α-PbCl2-type phase transition starts at 9.5 GPa and completes at 20.2 GPa. The phase-transition pressure is lower than that of 8 nm CaF2 nanocrystals and closer to bulk CaF2. Upon decompression, the fluorite and α-PbCl2-type structure co-exist at the ambient pressure. The bulk modulus B0 of the 23 nm CaF2 nanocrystals for the fluorite and α-PbCl2-type phase are 103(2 and 78(2 GPa, which are both larger than those of the bulk CaF2. The CaF2 nanocrystals exhibit obviously higher incompressibility compare to bulk CaF2. Further analysis demonstrates that the defect effect in our CaF2 nanocrystals plays a dominant role in the structural stability.

  6. Evaluation of gamma-ray intensities

    International Nuclear Information System (INIS)

    Yoshizawa, Yasukazu; Inoue, Hikaru; Hoshi, Masaharu; Shizuma, Kiyoshi; Iwata, Yosei.

    1978-03-01

    Results of literature survey and evaluation of relative intensities and intensities per decay of gamma rays are presented. Evaluations were made for 22 Na, 24 Na, 46 Sc, 48 Sc, 48 V, 54 Mn, 57 Co, 60 Co, 85 Sr, 88 Y, 95 Nb, 95 Zr, sup(108m)Ag, 134 Cs, 137 Cs, 144 Ce, 144 Pr, 203 Hg, and 207 Bi. For eight of the nuclides, the half-lives were also evaluated. (auth.)

  7. [Changes in Ca(2+)concentration and caspase-3 expression and their relationship in Raji cells exposed to electromagnetic radiation].

    Science.gov (United States)

    Wang, Wei; Liu, Huan-xin; Wang, De-wen; Zuo, Hong-yan; Peng, Rui-yun

    2013-02-01

    To study the effects of electromagnetic pulse (EMP), S-band high power microwave (S-HPM), and X-band high power microwave (X-HPM) on the Ca(2+) concentration and caspase-3 expression in Raji cells and the relationship between Ca(2+) concentration and caspase-3 expression, and to investigate the regulatory mechanism of electromagnetic radiation damage. Raji cells were cultured conventionally. Some cells were irradiated by EMP, S-HPM, and X-HPM in the logarithmic growth phase for 6 hours and then collected; others received sham irradiation as a control. The Ca(2+) concentration in the cells was measured by laser scanning confocal microscope; the caspase-3 expression in the cells was evaluated by Western blot. Compared with the control group (Ca(2+) fluorescence intensity = 43.08 ± 2.08; caspase-3 expression level = 0.444 ± 0.13), the EMP,S-HPM, and X-HPM groups had significantly increased Ca(2+) concentrations, with Ca(2+) fluorescence intensities of 69.56 ± 1.71, 50.06 ± 1.89, and 70.68 ± 1.59, respectively (P < 0.01), and had upregulated caspase-3 expression, with expression levels of 0.964 ± 0.12, 0.586 ± 0.16, and 0.970 ± 0.07, respectively (P < 0.01). Each of the EMP and X-HPM groups had significantly higher Ca(2+) fluorescence intensity and caspase-3 expression level than the S-HPM group (P < 0.01), but there were no significant differences between the EMP and X-HPM groups. The linear regression analysis showed that the caspase-3 expression was upregulated as the Ca(2+) concentration increased, with a positive correlation between them (P < 0.01). EMP, S-HPM, and X-HPM cause damage probably by increasing the Ca(2+) concentration in cells and in turn inducing caspase-3 overexpression.

  8. High Intensity Physical Exercise and Pain in the Neck and Upper Limb among Slaughterhouse Workers: Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Emil Sundstrup

    2014-01-01

    Full Text Available Slaughterhouse work involves a high degree of repetitive and forceful upper limb movements and thus implies an elevated risk of work-related musculoskeletal disorders. High intensity strength training effectively rehabilitates musculoskeletal disorders among sedentary employees, but less is known about the effect among workers with repetitive and forceful work demands. Before performing randomized controlled trials it may be beneficial to assess the cross-sectional connection between exercise and musculoskeletal pain. We investigated the association between high intensity physical exercise and pain among 595 slaughterhouse workers in Denmark, Europe. Using logistic regression analyses, odds ratios for pain and work disability as a function of physical exercise, gender, age, BMI, smoking, and job position were estimated. The prevalence of pain in the neck, shoulder, elbow, and hand/wrist was 48%, 60%, 40%, and 52%, respectively. The odds for experiencing neck pain were significantly lower among slaughterhouse workers performing physical exercise (OR = 0.70, CI: 0.49–0.997, whereas the odds for pain in the shoulders, elbow, or hand/wrist were not associated with exercise. The present study can be used as general reference of pain in the neck and upper extremity among slaughterhouse workers. Future studies should investigate the effect of high intensity physical exercise on neck and upper limb pain in slaughterhouse workers.

  9. Pulsed system for obtaining microdosimetric data with high intensity beams

    International Nuclear Information System (INIS)

    Zaider, M.; Dicello, J.F.; Hiebert, R.D.

    1977-01-01

    The use of heavy particle accelerators for radiation therapy requires high intensity beams in order to produce useful dose rates. The 800-MeV proton beam at LAMPF passes through different production targets to generate secondary pion beams. Conventional microdosimetric techniques are not applicable under these conditions because exceedingly high count rates result in detector damage, gas breakdown, and saturation effects in the electronics. We describe a new microdosimetric system developed at the Pion Biomedical Channel of LAMPF. The accelerator provides a variable low intensity pulse once every ten high intensity macropulses. The voltage on the detector is pulsed in coincidence with the low intensity pulse so that we were able to operate the detector under optimum data-taking conditions. A low noise two-stage preamplifier was built in connection with the pulsed mode operation. A comparison is made between data obtained in pulsed (high intensity beam) and unpulsed (low intensity beam) modes. The spectra obtained by the two methods agree within the experimental uncertainties

  10. High-speed digital imaging of cytosolic Ca2+ and contraction in single cardiomyocytes.

    Science.gov (United States)

    O'Rourke, B; Reibel, D K; Thomas, A P

    1990-07-01

    A charge-coupled device (CCD) camera, with the capacity for simultaneous spatially resolved photon counting and rapid frame transfer, was utilized for high-speed digital image collection from an inverted epifluorescence microscope. The unique properties of the CCD detector were applied to an analysis of cell shortening and the Ca2+ transient from fluorescence images of fura-2-loaded [corrected] cardiomyocytes. On electrical stimulation of the cell, a series of sequential subimages was collected and used to create images of Ca2+ within the cell during contraction. The high photosensitivity of the camera, combined with a detector-based frame storage technique, permitted collection of fluorescence images 10 ms apart. This rate of image collection was sufficient to resolve the rapid events of contraction, e.g., the upstroke of the Ca2+ transient (less than 40 ms) and the time to peak shortening (less than 80 ms). The technique was used to examine the effects of beta-adrenoceptor activation, fura-2 load, and stimulus frequency on cytosolic Ca2+ transients and contractions of single cardiomyocytes. beta-Adrenoceptor stimulation resulted in pronounced increases in peak Ca2+, maximal rates of rise and decay of Ca2+, extent of shortening, and maximal velocities of shortening and relaxation. Raising the intracellular load of fura-2 had little effect on the rising phase of Ca2+ or the extent of shortening but extended the duration of the Ca2+ transient and contraction. In related experiments utilizing differential-interference contrast microscopy, the same technique was applied to visualize sarcomere dynamics in contracting cells. This newly developed technique is a versatile tool for analyzing the Ca2+ transient and mechanical events in studies of excitation-contraction coupling in cardiomyocytes.

  11. Laser-matter interaction at high intensity and high temporal contrast

    International Nuclear Information System (INIS)

    Doumy, G.

    2006-01-01

    The continuous progress in the development of laser installations has already lead to ultra-short pulses capable of achieving very high focalized intensities (I > 10 18 W/cm 2 ). At these intensities, matter presents new non-linear behaviours, due to the fact that the electrons are accelerated to relativistic speeds. The experimental access to this interaction regime on solid targets has long been forbidden because of the presence, alongside the femtosecond pulse, of a pedestal (mainly due to the amplified spontaneous emission (ASE) which occurs in the laser chain) intense enough to modify the state of the target. In this thesis, we first characterized, both experimentally and theoretically, a device which allows an improvement of the temporal contrast of the pulse: the Plasma Mirror. It consists in adjusting the focusing of the pulse on a dielectric target, so that the pedestal is mainly transmitted, while the main pulse is reflected by the overcritical plasma that it forms at the surface. The implementation of such a device on the UHI 10 laser facility (CEA Saclay - 10 TW - 60 fs) then allowed us to study the interaction between ultra-intense, high contrast pulses with solid targets. In a first part, we managed to generate and characterize dense plasmas resulting directly from the interaction between the main pulse and very thin foils (100 nm). This characterization was realized by using an XUV source obtained by high order harmonics generation in a rare gas jet. In a second part, we studied experimentally the phenomenon of high order harmonics generation on solid targets, which is still badly understood, but could potentially lead to a new kind of energetic ultra-short XUV sources. (author)

  12. High performance CaS solar-blind ultraviolet photodiodes fabricated by seed-layer-assisted growth

    International Nuclear Information System (INIS)

    He, Qing Lin; Lai, Ying Hoi; Sou, Iam Keong; Liu, Yi; Beltjens, Emeline; Qi, Jie

    2015-01-01

    CaS, with a direct bandgap of 5.38 eV, is expected to be a strong candidate as the active-layer of high performance solar-blind UV photodiodes that have important applications in both civilian and military sectors. Here, we report that a seed-layer-assisted growth approach via molecular beam epitaxy can result in high crystalline quality rocksalt CaS thin films on zincblende GaAs substrates. The Au/CaS/GaAs solar-blind photodiodes demonstrated , more than five orders in its visible rejection power, a photoresponse of 36.8 mA/w at zero bias and a corresponding quantum efficiency as high as 19% at 235 nm

  13. Ca2+/cation antiporters (CaCA: Identification, characterization and expression profiling in bread wheat (Triticum aestivum L.

    Directory of Open Access Journals (Sweden)

    Mehak Taneja

    2016-11-01

    Full Text Available The Ca2+/cation antiporters (CaCA superfamily proteins play vital function in Ca2+ ion homeostasis, which is an important event during development and defense response. Molecular characterization of these proteins has been performed in certain plants, but they are still not characterized in Triticum aestivum (bread wheat. Herein, we identified thirty four TaCaCA superfamily proteins, which were classified into TaCAX, TaCCX, TaNCL and TaMHX protein families based on their structural organization and evolutionary relation with earlier reported proteins. Since the T. aestivum comprises an allohexaploid genome, TaCaCA genes were derived from each A, B and D subgenome and homeologous chromosome (HC, except chromosome-group 1. Majority of genes were derived from more than one HCs in each family that were considered as homeologous genes (HGs due to their high similarity with each other. These HGs showed comparable gene and protein structures in terms of exon/intron organization and domain architecture. Majority of TaCaCA proteins comprised two Na_Ca_ex domains. However, TaNCLs consisted of an additional EF-hand domain with calcium binding motifs. Each TaCaCA protein family consisted of about ten transmembrane and two α-repeat regions with specifically conserved signature motifs except TaNCL, which had single α-repeat. Variable expression of most of the TaCaCA genes during various developmental stages suggested their specified role in development. However, constitutively high expression of a few genes like TaCAX1-A and TaNCL1-B indicated their role throughout the plant growth and development. The modulated expression of certain genes during biotic (fungal infections and abiotic stresses (heat, drought, salt suggested their role in stress response. Majority of TaCCX and TaNCL family genes were found highly affected during various abiotic stresses. However the role of individual gene needs to be established. The present study unfolded the opportunity

  14. Ca2+/Cation Antiporters (CaCA): Identification, Characterization and Expression Profiling in Bread Wheat (Triticum aestivum L.).

    Science.gov (United States)

    Taneja, Mehak; Tyagi, Shivi; Sharma, Shailesh; Upadhyay, Santosh Kumar

    2016-01-01

    The Ca 2+ /cation antiporters (CaCA) superfamily proteins play vital function in Ca 2+ ion homeostasis, which is an important event during development and defense response. Molecular characterization of these proteins has been performed in certain plants, but they are still not characterized in Triticum aestivum (bread wheat). Herein, we identified 34 TaCaCA superfamily proteins, which were classified into TaCAX, TaCCX, TaNCL, and TaMHX protein families based on their structural organization and evolutionary relation with earlier reported proteins. Since the T. aestivum comprises an allohexaploid genome, TaCaCA genes were derived from each A, B, and D subgenome and homeologous chromosome (HC), except chromosome-group 1. Majority of genes were derived from more than one HCs in each family that were considered as homeologous genes (HGs) due to their high similarity with each other. These HGs showed comparable gene and protein structures in terms of exon/intron organization and domain architecture. Majority of TaCaCA proteins comprised two Na_Ca_ex domains. However, TaNCLs consisted of an additional EF-hand domain with calcium binding motifs. Each TaCaCA protein family consisted of about 10 transmembrane and two α-repeat regions with specifically conserved signature motifs except TaNCL, which had single α-repeat. Variable expression of most of the TaCaCA genes during various developmental stages suggested their specified role in development. However, constitutively high expression of a few genes like TaCAX1-A and TaNCL1-B indicated their role throughout the plant growth and development. The modulated expression of certain genes during biotic (fungal infections) and abiotic stresses (heat, drought, salt) suggested their role in stress response. Majority of TaCCX and TaNCL family genes were found highly affected during various abiotic stresses. However, the role of individual gene needs to be established. The present study unfolded the opportunity for detail

  15. Highly active and durable Ca-doped Ce-SBA-15 catalyst for biodiesel production

    International Nuclear Information System (INIS)

    Thitsartarn, Warintorn; Maneerung, Thawatchai; Kawi, Sibudjing

    2015-01-01

    In this work, Ca-doped Ce-incorporated SBA-15 (Ca/CeS) catalyst was successfully synthesized by using direct synthesis of Ce-incorporated SBA-15 followed by impregnation of CaO (calcium oxide). The maximum Si/Ce molar ratio that Ce atoms can be incorporated successfully into the mesoporous framework was found to be 5 (CeS-5). After the impregnation of 30 wt. % Ca, the obtained 30Ca/CeS-5 catalysts showed the superior catalytic performance for transesterification reaction of palm oil with methanol and also the higher catalytic activity as compared to other supported catalysts, i.e. CaO/CeO 2 and CaO–CeO 2 /SBA-15. This can be attributed to the well-dispersion of CaO on the CeS-5 support surface. Furthermore, it was found that the leaching of Si, Ce and Ca from the catalyst into biodiesel produced was negligible (i.e. <1 ppm after 7 cycles), indicating the strong interaction between CaO and CeS-5 support. As a result, the 30Ca/CeS-5 catalyst can be reused at least 15 cycles with insignificant decrease in catalytic activity, offering the efficient CaO-based catalyst for biodiesel production. - Highlights: • Mesoporous Ca-based catalyst was successfully developed for biodiesel production. • Catalyst exhibited high activity towards transesterification (FAME yield > 98%). • Catalyst can be effectively re-used at least 15 cycles. • Extremely low catalyst contaminant (<1 ppm) was presented

  16. Half-integer resonance crossing in high-intensity rings

    Directory of Open Access Journals (Sweden)

    A. V. Fedotov

    2002-02-01

    Full Text Available A detailed study of the influence of space charge on the crossing of second-order resonances is presented and associated with the space-charge limit of high-intensity rings. Two-dimensional simulation studies are compared with envelope models, which agree in the finding of an increased intensity limit due to the coherent frequency shift. This result is also found for realistic bunched beams with multiturn injection painting. Characteristic features such as the influence of tune splitting, structure resonances, and the role of envelope instabilities are discussed in detail. The theoretical limits are found to be in good agreement with the performance of high-intensity proton machines.

  17. LHC Report: reaching high intensity

    CERN Multimedia

    Jan Uythoven

    2015-01-01

    After both beams having been ramped to their full energy of 6.5 TeV, the last two weeks saw the beam commissioning process advancing on many fronts. An important milestone was achieved when operators succeeded in circulating a nominal-intensity bunch. During the operation, some sudden beam losses resulted in beam dumps at top energy, a problem that needed to be understood and resolved.   In 2015 the LHC will be circulating around 2800 bunches in each beam and each bunch will contain just over 1 x 1011 protons. Until a few days ago commissioning was taking place with single bunches of 5 x 109 protons. The first nominal bunch with an intensity of 1 x 1011 protons was injected on Tuesday, 21 April. In order to circulate such a high-intensity bunch safely, the whole protection system must be working correctly: collimators, which protect the aperture, are set at preliminary values known as coarse settings; all kicker magnets for injecting and extracting the beams are commissioned with beam an...

  18. Underutilization of high-intensity statin therapy after hospitalization for coronary heart disease.

    Science.gov (United States)

    Rosenson, Robert S; Kent, Shia T; Brown, Todd M; Farkouh, Michael E; Levitan, Emily B; Yun, Huifeng; Sharma, Pradeep; Safford, Monika M; Kilgore, Meredith; Muntner, Paul; Bittner, Vera

    2015-01-27

    National guidelines recommend use of high-intensity statins after hospitalization for coronary heart disease (CHD) events. This study sought to estimate the proportion of Medicare beneficiaries filling prescriptions for high-intensity statins after hospital discharge for a CHD event and to analyze whether statin intensity before hospitalization is associated with statin intensity after discharge. We conducted a retrospective cohort study using a 5% random sample of Medicare beneficiaries between 65 and 74 years old. Beneficiaries were included in the analysis if they filled a statin prescription after a CHD event (myocardial infarction or coronary revascularization) in 2007, 2008, or 2009. High-intensity statins included atorvastatin 40 to 80 mg, rosuvastatin 20 to 40 mg, and simvastatin 80 mg. Among 8,762 Medicare beneficiaries filling a statin prescription after a CHD event, 27% of first post-discharge fills were for a high-intensity statin. The percent filling a high-intensity statin post-discharge was 23.1%, 9.4%, and 80.7%, for beneficiaries not taking statins pre-hospitalization, taking low/moderate-intensity statins, and taking high-intensity statins before their CHD event, respectively. Compared with beneficiaries not on statin therapy pre-hospitalization, multivariable adjusted risk ratios for filling a high-intensity statin were 4.01 (3.58-4.49) and 0.45 (0.40-0.52) for participants taking high-intensity and low/moderate-intensity statins before their CHD event, respectively. Only 11.5% of beneficiaries whose first post-discharge statin fill was for a low/moderate-intensity statin filled a high-intensity statin within 365 days of discharge. The majority of Medicare beneficiaries do not fill high-intensity statins after hospitalization for CHD. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. The effects of high-Ca hardness water treatment for secondary cooling water in HANARO

    International Nuclear Information System (INIS)

    Kang, T. J.; Park, Y. C.; Hwang, S. R.; Lim, I. C.; Choi, H. Y.

    2003-01-01

    Water-quality control of the second cooling system in HANARO has been altered from low Ca-hardness treatment to high Ca-hardness treatment since March, 2001. High Ca-hardness water treatment in HANARO is to maintain the calcium hardness around 12 by minimizing the blowdown of secondary cooling water. This paper describes the effect of cost reduction after change of water-quility treatment method. The result shows that the cost of the water could be reduced by 25% using the pond water in KAERI. The amount and cost for the chemical agent could be reduced by 40% and 10% respectively

  20. Cryogenic semiconductor high-intensity radiation monitors

    International Nuclear Information System (INIS)

    Palmieri, V.G.; Bell, W.H.; Borer, K.; Casagrande, L.; Da Via, C.; Devine, S.R.H.; Dezillie, B.; Esposito, A.; Granata, V.; Hauler, F.; Jungermann, L.; Li, Z.; Lourenco, C.; Niinikoski, T.O.; Shea, V. O'; Ruggiero, G.; Sonderegger, P.

    2003-01-01

    This paper describes a novel technique to monitor high-intensity particle beams by means of a semiconductor detector. It consists of cooling a semiconductor detector down to cryogenic temperature to suppress the thermally generated leakage current and to precisely measure the integrated ionization signal. It will be shown that such a device provides very good linearity and a dynamic range wider than is possible with existing techniques. Moreover, thanks to the Lazarus effect, extreme radiation hardness can be achieved providing in turn absolute intensity measurements against precise calibration of the device at low beam flux

  1. High ca-hardness treatment program of secondary cooling system in HANARO

    International Nuclear Information System (INIS)

    Park, Y. C.; Woo, J. S.; Ryu, J. S.; Cho, Y. K.; Jeon, B. J.

    2002-01-01

    The secondary cooling water in HANARO had been treated with a low ca-hardness treatment program. The program has now been altered to a high ca-hardness treatment program to reduce the consumption of service water and the maintenance cost. After the alteration of the water treatment method, the water quality of the secondary cooling system is maintained below the limit of water quality control as same as before the alteration. This means indirectly that the secondary cooling system is not much affected by the water quality. To confirm this fact, it is necessary to analyze the effects of corrosion, scale, sludgy and slime that the water qualities are directly interfered with the secondary cooling system. We analyzed the deteriorating effects with a water monitoring equipment connected to the secondary cooling system to measure the monitoring parameters every 6 months. As a result, it is confirmed through this examination that the effects are maintained below the control limits and the high ca-hardness treatment program is applicable to treatment of the water quality of the secondary cooling system in HANARO

  2. Evaluation of a real-time PCR assay for rectal screening of OXA-48-producing Enterobacteriaceae in a general intensive care unit of an endemic hospital.

    Science.gov (United States)

    Fernández, J; Cunningham, S A; Fernández-Verdugo, A; Viña-Soria, L; Martín, L; Rodicio, M R; Escudero, D; Vazquez, F; Mandrekar, J N; Patel, R

    2017-07-01

    Carbapenemase-producing Enterobacteriaceae are increasing worldwide. Rectal screening for these bacteria can inform the management of infected and colonized patients, especially those admitted to intensive care units (ICUs). A laboratory developed, qualitative duplex real-time polymerase chain reaction assay for rapid detection of OXA-48-like and VIM producing Enterobacteriaceae, performed on rectal swabs, was designed and evaluated in an intensive care unit with endemic presence of OXA-48. During analytical assay validation, no cross-reactivity was observed and 100% sensitivity and specificity were obtained for both bla OXA-48-like and bla VIM in all spiked clinical samples. During the clinical part of the study, the global sensitivity and specificity of the real-time PCR assay for OXA-48 detection were 95.7% and 100% (P=0.1250), respectively, in comparison with culture; no VIM-producing Enterobacteriaceae were detected. Clinical features of patients in the ICU who were colonized or infected with OXA-48 producing Enterobacteriaceae, including outcome, were analyzed. Most had severe underlying conditions, and had risk factors for colonization with carbapenemase-producing Enterobacteriaceae before or during ICU admission, such as receiving previous antimicrobial therapy, prior healthcare exposure (including long-term care), chronic disease, immunosuppression and/or the presence of an intravascular catheter and/or mechanical ventilation device. The described real-time PCR assay is fast (~2-3hours, if DNA extraction is included), simple to perform and results are easy to interpret, features which make it applicable in the routine of clinical microbiology laboratories. Implementation in endemic hospitals could contribute to early detection of patients colonized by OXA-48 producing Enterobacteriaceae and prevention of their spread. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Analysis of technology and seminar on economic trends about High-intensity LED

    International Nuclear Information System (INIS)

    2003-09-01

    This is divided into two parts. Contents of this report in the first part are technical trends on high-intensity LED which reports introduction of LED as compound semiconductor, white LED? patent issues, review on technology of High-intensity LED and Reliability of High-intensity LED. The second part deals with economic tends about High-intensity LED. This seminar was held to report analysis and economical trends about High-intensity LED by Korea Industrial Education Institute in 2003.

  4. The effect of adding antimicrobial peptides to milk inoculated with Staphylococcus aureus and processed by high-intensity pulsed-electric field.

    Science.gov (United States)

    Sobrino-Lopez, A; Viedma-Martínez, P; Abriouel, H; Valdivia, E; Gálvez, A; Martin-Belloso, O

    2009-06-01

    The use of high-intensity pulsed-electric field (HIPEF) and antimicrobial substances of natural origin, such as enterocin AS-48 (AS-48), nisin, and lysozyme, are among the most important nonthermal preservation methods. Thus, the purpose of this study was to evaluate the combined effect on milk inoculated with Staphylococcus aureus of the addition of AS-48 with nisin or lysozyme, or both, together with the use of HIPEF. Synergy was observed in the reduction of Staph. aureus counts with the following combination methods: i) addition of AS-48 and nisin, ii) addition of AS-48 plus use of HIPEF, and iii) addition of AS-48 and nisin plus use of HIPEF. Specifically, when 28 arbitrary units/mL of AS-48 and 20 IU/mL of nisin were added to the milk, and it was treated with HIPEF for 800 mus, over 6 log reductions were observed in the microorganism. In general, Staph. aureus inactivation was dependent on HIPEF treatment time, antimicrobial doses, and medium pH. During storage of the treated milk, survivor population was related to peptide concentration and temperature. Final cell viability was influenced by the sequence in which the treatments were applied: the addition of AS-48 or AS-48 and nisin was more effective before than after HIPEF treatment. The results obtained indicate that the combination of HIPEF and antimicrobials could be of great interest to the dairy industry, although it is necessary to study further the way in which the combined treatments act.

  5. Generation of Ultra-high Intensity Laser Pulses

    International Nuclear Information System (INIS)

    Fisch, N.J.; Malkin, V.M.

    2003-01-01

    Mainly due to the method of chirped pulse amplification, laser intensities have grown remarkably during recent years. However, the attaining of very much higher powers is limited by the material properties of gratings. These limitations might be overcome through the use of plasma, which is an ideal medium for processing very high power and very high total energy. A plasma can be irradiated by a long pump laser pulse, carrying significant energy, which is then quickly depleted in the plasma by a short counterpropagating pulse. This counterpropagating wave effect has already been employed in Raman amplifiers using gases or plasmas at low laser power. Of particular interest here are the new effects which enter in high power regimes. These new effects can be employed so that one high-energy optical system can be used like a flashlamp in what amounts to pumping the plasma, and a second low-power optical system can be used to extract quickly the energy from the plasma and focus it precisely. The combined system can be very compact. Thus, focused intensities more than 10 25 W/cm 2 can be contemplated using existing optical elements. These intensities are several orders of magnitude higher than what is currently available through chirped pump amplifiers

  6. Preparation of a highly concentrated, completely monomeric, active sarcoplasmic reticulum Ca2+-ATPase.

    Science.gov (United States)

    Lüdi, H; Hasselbach, W

    1985-11-21

    Sarcoplasmic reticulum vesicles from fast skeletal muscle were partially delipidated with sodium cholate at high ionic strength and sedimented in a discontinuous sucrose gradient. Phospholipid content was reduced from 0.777 mumol/mg protein to 0.242 mumol/mg protein. As judged from gel electrophoresis and high pressure liquid gel chromatography, accessory proteins were removed during centrifugation and the Ca2+-ATPase was obtained in an almost pure form. Addition of myristoylglycerophosphocholine (1 mg/mg protein) reactivates ATPase and dinitrophenylphosphatase activity to the same degree obtained with native vesicles. Using the analytical ultracentrifuge it could be demonstrated that the reactivated Ca2+-ATPase was present exclusively in a monomeric state. These results were obtained at high and low ionic strength and up to a protein concentration of 10 mg/ml. Therefore this preparation should be very useful to investigate differences between oligomeric and monomeric Ca2+-ATPase.

  7. Spectral properties and laser performances of Yb3+:LaCa4O(BO3)3 crystal with high concentration doping

    International Nuclear Information System (INIS)

    Ji, Yuexia; Cao, Jiafeng; Xu, Jinlong; You, Zhenyu; Zhu, Zhaojie; Li, Jianfu; Wang, Yan; Tu, Chaoyang

    2013-01-01

    Highlights: •Yb 3+ :LaCa 4 O(BO 3 ) 3 single crystal was grown with high concentration doping. •Laser potentiality was evaluated based on the spectral and laser parameters. •Continuous wave laser operation was realized. •An output power of 0.77 W and a slope efficiency of 15.71% at 1077 nm were obtained. •The spectra and laser properties of Yb 3+ :LaCa 4 O(BO 3 ) 3 crystal were firstly reported. -- Abstract: High concentration of 15 at.% Yb 3+ doped LaCa 4 O(BO 3 ) 3 (LaCOB) crystal was grown by Czochralski technique. The absorption cross section was conclulated to be 0.63 × 10 −20 cm 2 at 977 nm and the emission cross section to be 0.39 × 10 −20 cm 2 at 1030 nm, with the FWHM of 6.15 and 33 nm respectively. Laser potentiality was evaluated based on the gain cross section σ g , the minimum inversion fraction β min and the minimum pump intensity I min , which were calculated to be 0.18 × 10 −20 cm 2 , 0.05 and 0.47 kw/cm 2 , respectively. Continuous wave laser operation was realized with an output power of 0.77 W and a slope efficiency of 15.71%. The laser emitted around 1077 nm. The radiation trapping and continuous pump mode are contributed to the lasing wavelength for present crystal

  8. MO-AB-210-03: Workshop [Advancements in high intensity focused ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Z. [University of Chicago (United States)

    2015-06-15

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  9. Measurement of absorbed dose for high energy electron using CaSO4: Tm-PTFE TLD

    International Nuclear Information System (INIS)

    Park, Myeong Hwan; Kim, Do Sung

    2000-01-01

    In this study, the highly sensitive CaSO 4 : Tm-PTFE TLDs has been fabricated for the purpose of measurement of high energy electron. CaSO 4 : Tm phosphor powder was mixed with polytetrafluoroethylene(PTFE) powder and moulded in a disk type(diameter 8.5mm, thickness 90mg/cm 2 ) by cold pressing. The absorbed dose distribution and ranges for high energy electron were measured by using the CaSO 4 : Tm-PTFE TLDs. The ranges determined were R 100 =3D14.5mm, R 50 =3D24.1mm and R p =3D31.8mm, respectively and the beam flatness, the variation of relative dose in 80% of the field size, was 4.5%. The fabricated CaSO 4 : Tm-PTFE TLDs may be utilized in radiation dosimetry for personal, absorbed dose and environmental monitoring.=20

  10. Electrical behavior of Ca, Sr, Ba, and Eu at very high pressures and low temperatures

    International Nuclear Information System (INIS)

    Bundy, F.P.; Dunn, K.J.

    1981-01-01

    Compression of Ca and Sr initially causes an increase in resistivity, probably because of uncrossing of conduction and valence bands. Then at about 180 kbar for Ca and about 35 kbar for Sr the resistivity drops quite abruptly, following which the resistivity again increases with additional pressure, similar to the behavior of Ba starting at room pressure. The high pressure forms of Ba have already been reported to be superconducting, and the experiments confirm this. Superconductivity appears in Sr at about 350 kbar and develops strongly at higher pressures. In the 440 kbar experiment on Ca a resistance drop started at the lower threshold of the temperature capability, 2.1K, suggesting that Ca, too, becomes superconducting at sufficiently high pressures. The high pressure form of Eu above 125 kbar was tested for superconductivity down to 2.2K with negative results. (Auth.)

  11. In-beam separation and mass determination of superheavy nuclei

    International Nuclear Information System (INIS)

    Malyshev, O.N.; Eremin, A.V.; Popeko, A.G.

    2003-01-01

    Within the past fifteen years, the recoil separator VASSILISSA has been used for the investigations of evaporation residues produced in complete fusion reactions induced by heavy ions. The study of decay properties and formation cross sections of the isotopes of elements 110, 112 and 114 was performed using high intensity 48 Ca beams and 232 Th, 238 U, 242 Pu targets. For further experiments aimed at the synthesis of the superheavy element isotopes (Z≥110) with the use of intense 48 Ca extracted beams, improvements in the ion optical system of the separator and the focal plane detector system have been made. The results from the test reactions and new result for the isotope 283 112 are presented

  12. A close association of RyRs with highly dense clusters of Ca2+-activated Cl- channels underlies the activation of STICs by Ca2+ sparks in mouse airway smooth muscle.

    Science.gov (United States)

    Bao, Rongfeng; Lifshitz, Lawrence M; Tuft, Richard A; Bellvé, Karl; Fogarty, Kevin E; ZhuGe, Ronghua

    2008-07-01

    Ca(2+) sparks are highly localized, transient releases of Ca(2+) from sarcoplasmic reticulum through ryanodine receptors (RyRs). In smooth muscle, Ca(2+) sparks trigger spontaneous transient outward currents (STOCs) by opening nearby clusters of large-conductance Ca(2+)-activated K(+) channels, and also gate Ca(2+)-activated Cl(-) (Cl((Ca))) channels to induce spontaneous transient inward currents (STICs). While the molecular mechanisms underlying the activation of STOCs by Ca(2+) sparks is well understood, little information is available on how Ca(2+) sparks activate STICs. In the present study, we investigated the spatial organization of RyRs and Cl((Ca)) channels in spark sites in airway myocytes from mouse. Ca(2+) sparks and STICs were simultaneously recorded, respectively, with high-speed, widefield digital microscopy and whole-cell patch-clamp. An image-based approach was applied to measure the Ca(2+) current underlying a Ca(2+) spark (I(Ca(spark))), with an appropriate correction for endogenous fixed Ca(2+) buffer, which was characterized by flash photolysis of NPEGTA. We found that I(Ca(spark)) rises to a peak in 9 ms and decays with a single exponential with a time constant of 12 ms, suggesting that Ca(2+) sparks result from the nonsimultaneous opening and closure of multiple RyRs. The onset of the STIC lags the onset of the I(Ca(spark)) by less than 3 ms, and its rising phase matches the duration of the I(Ca(spark)). We further determined that Cl((Ca)) channels on average are exposed to a [Ca(2+)] of 2.4 microM or greater during Ca(2+) sparks. The area of the plasma membrane reaching this level is <600 nm in radius, as revealed by the spatiotemporal profile of [Ca(2+)] produced by a reaction-diffusion simulation with measured I(Ca(spark)). Finally we estimated that the number of Cl((Ca)) channels localized in Ca(2+) spark sites could account for all the Cl((Ca)) channels in the entire cell. Taken together these results lead us to propose a model in which

  13. High-intensity interval training and athletic performance in Taekwondo athletes.

    Science.gov (United States)

    Monks, Lynne; Seo, Myong-Won; Kim, Hyun-Bae; Jung, Hyun C; Song, Jong K

    2017-10-01

    The purpose of this study was to determine the effects of high-intensity interval training (HIIT) on athletic performance in Taekwondo athletes. Thirty-three male and female collegiate Taekwondo athletes were randomly divided into a HIIT group (N.=16) or a high-intensity continuous running (HICR) group (N.=17). The HIIT group undertook training of high-intensity sprints interspersed with active rest periods whilst the HICR group participated in high-intensity running for a continuous period. Both groups completed 11 sessions over 4 weeks. Physique, body composition, Wingate anaerobic test and VO2max test were measured. The vertical jump test, agility T-test and sit-ups were used to assess physical fitness. Repeated measures ANCOVAs with sex as a covariate were applied and significant level was set at 0.05. Following 11 sessions of training, significant improvements in anaerobic peak power (Ptraining, specifically the influence of training intensity on anaerobic capacity.

  14. Beetroot Juice Supplementation Improves High-Intensity Intermittent Type Exercise Performance in Trained Soccer Players

    Directory of Open Access Journals (Sweden)

    Jean Nyakayiru

    2017-03-01

    Full Text Available It has been shown that nitrate supplementation can enhance endurance exercise performance. Recent work suggests that nitrate ingestion can also increase intermittent type exercise performance in recreational athletes. We hypothesized that six days of nitrate supplementation can improve high-intensity intermittent type exercise performance in trained soccer players. Thirty-two male soccer players (age: 23 ± 1 years, height: 181 ± 1 m, weight: 77 ± 1 kg, playing experience: 15.2 ± 0.5 years, playing in the first team of a 2nd or 3rd Dutch amateur league club participated in this randomized, double-blind cross-over study. All subjects participated in two test days in which high-intensity intermittent running performance was assessed using the Yo-Yo IR1 test. Subjects ingested nitrate-rich (140 mL; ~800 mg nitrate/day; BR or a nitrate-depleted beetroot juice (PLA for six subsequent days, with at least eight days of wash-out between trials. The distance covered during the Yo-Yo IR1 was the primary outcome measure, while heart rate (HR was measured continuously throughout the test, and a single blood and saliva sample were collected just prior to the test. Six days of BR ingestion increased plasma and salivary nitrate and nitrite concentrations in comparison to PLA (p < 0.001, and enhanced Yo-Yo IR1 test performance by 3.4 ± 1.3% (from 1574 ± 47 to 1623 ± 48 m; p = 0.027. Mean HR was lower in the BR (172 ± 2 vs. PLA trial (175 ± 2; p = 0.014. Six days of BR ingestion effectively improves high-intensity intermittent type exercise performance in trained soccer players.

  15. On the duration and intensity of cumulative advantage competitions

    International Nuclear Information System (INIS)

    Jiang, Bo; Towsley, Don; Sun, Liyuan; Figueiredo, Daniel R; Ribeiro, Bruno

    2015-01-01

    Network growth can be framed as a competition for edges among nodes in the network. As with various other social and physical systems, skill (fitness) and luck (random chance) act as fundamental forces driving competition dynamics. In the context of networks, cumulative advantage (CA)—the rich-get-richer effect—is seen as a driving principle governing the edge accumulation process. However, competitions coupled with CA exhibit non-trivial behavior and little is formally known about duration and intensity of CA competitions. By isolating two nodes in an ideal CA competition, we provide a mathematical understanding of how CA exacerbates the role of luck in detriment of skill. We show, for instance, that when nodes start with few edges, an early stroke of luck can place the less skilled in the lead for an extremely long period of time, a phenomenon we call ‘struggle of the fittest’. We prove that duration of a simple skill and luck competition model exhibit power-law tails when CA is present, regardless of skill difference, which is in sharp contrast to the exponential tails when fitness is distinct but CA is absent. We also prove that competition intensity is always upper bounded by an exponential tail, irrespective of CA and skills. Thus, CA competitions can be extremely long (infinite mean, depending on fitness ratio) but almost never very intense. The theoretical results are corroborated by extensive numerical simulations. Our findings have important implications to competitions not only among nodes in networks but also in contexts that leverage socio-physical models embodying CA competitions. (paper)

  16. On the duration and intensity of cumulative advantage competitions

    Science.gov (United States)

    Jiang, Bo; Sun, Liyuan; Figueiredo, Daniel R.; Ribeiro, Bruno; Towsley, Don

    2015-11-01

    Network growth can be framed as a competition for edges among nodes in the network. As with various other social and physical systems, skill (fitness) and luck (random chance) act as fundamental forces driving competition dynamics. In the context of networks, cumulative advantage (CA)—the rich-get-richer effect—is seen as a driving principle governing the edge accumulation process. However, competitions coupled with CA exhibit non-trivial behavior and little is formally known about duration and intensity of CA competitions. By isolating two nodes in an ideal CA competition, we provide a mathematical understanding of how CA exacerbates the role of luck in detriment of skill. We show, for instance, that when nodes start with few edges, an early stroke of luck can place the less skilled in the lead for an extremely long period of time, a phenomenon we call ‘struggle of the fittest’. We prove that duration of a simple skill and luck competition model exhibit power-law tails when CA is present, regardless of skill difference, which is in sharp contrast to the exponential tails when fitness is distinct but CA is absent. We also prove that competition intensity is always upper bounded by an exponential tail, irrespective of CA and skills. Thus, CA competitions can be extremely long (infinite mean, depending on fitness ratio) but almost never very intense. The theoretical results are corroborated by extensive numerical simulations. Our findings have important implications to competitions not only among nodes in networks but also in contexts that leverage socio-physical models embodying CA competitions.

  17. High-temperature crystal chemistry of layered calcium borosilicates: CaBSiO4(OH) (datolite), Ca4B5Si3O15(OH)5 (`bakerite') and Ca2B2SiO7 (synthetic analogue of okayamalite)

    Science.gov (United States)

    Krzhizhanovskaya, Maria G.; Gorelova, L. A.; Bubnova, R. S.; Pekov, I. V.; Krivovichev, S. V.

    2018-05-01

    The high-temperature behaviour of three Ca borosilicates has been studied by in situ powder high-temperature X-ray diffraction (HTXRD), differential scanning calorimetry and thermogravimetry in the temperature range 30-900 °C for natural samples of datolite, CaBSiO4(OH), and `bakerite', Ca4B5Si3O15(OH)5, and a synthetic analogue of okayamalite, Ca2B2SiO7. The latter was obtained by heating datolite at 800 °C for 5 h. Datolite and bakerite start to dehydroxylate above 700 and 500 °C, respectively, and decompose fully to form a high-temperature modification of okayamalite, HT-Ca2B2SiO7, and wollastonite, CaSiO3 at about 730 °C. Above 900 °C, HT-okayamalite decomposes with the formation of wollastonite, CaSiO3, and metaborate CaB2O4. The latter melts at about 990 °C. Above 1000 °C, only the existence of wollastonite, CaSiO3 and cristobalite, SiO2 was observed. According to the HTXRD data, in the temperature range 30-500 °C, datolite and `bakerite' demonstrate very similar and relatively low volumetric thermal expansion: α v = 29 and 27 × 10-6 °C-1, respectively. A high thermal expansion anisotropy ( α max/ α min 3) is caused by both the layered character of the crystal structures and the shear deformations of their monoclinic unit cells. The direction of maximum expansion is intermediate between the normal direction to the layers and the ( a + c) vector. A possible transformation mechanism from the datolite to the okayamalite structure topology is proposed from geometrical considerations. The synthetic analogue of okayamalite, Ca2B2SiO7, undergoes a reversible polymorphic transition at about 550 °C with a decrease in symmetry from tetragonal to orthorhombic. The crystal structure of the high-temperature (HT) modification of okayamalite was solved from the powder-diffraction data [900 °C: P21212, a = 7.3361(4), b = 7.1987(4), c = 4.8619(4) Å, V = 256.76(3) Å3, R wp = 6.61, R Bragg = 2.68%].

  18. Emission lines of Mg2 and Ca2 in planetary nebulae

    International Nuclear Information System (INIS)

    Gurzadyan, G.A.

    1979-01-01

    Conditions of exciting resonance lines in the emission of ionized magnesium (lambda lambda 2796+2803 Mg2) and calcium (lambda lambda 3934+3968 Ca2) in planetary nebulae have been analyzed. It is shown that the allowed lines are excited with the same mechanism, as the forbidden lines, i.e. inelastic electron collisions, but not with common fluorescence. The emission line lambda 2800 Mg2 of enough force can be observed only in the spectra of planetary nebulae with mean excitation (IC 2149) as well as in the spectra of diffuse nebulae. The line must not be observed in high-excited planetary nebulae (NGC 7026, 7662). The absence of emission lines H and K Ca2 in planetary nebulae spectra results from the fact, that their expected intensity is by 3-4 orders less than the intensity of the line lambda 2800 Mg2 or Hsub(β) hydrogen

  19. Isospin influence on the decay modes of the systems produced in the 78,86Kr +40,48Ca reactions at 10 AMeV

    Directory of Open Access Journals (Sweden)

    Gnoffo B.

    2016-01-01

    Full Text Available The results of the analysis of the reactions 78,86Kr +40,48 Ca at 10 AMeV are presented. The experiment was performed at the INFN Laboratori Nazionali del Sud (LNS in Catania by using the 4π multidetector CHIMERA, with beams delivered by the Superconductive Cyclotron. The competition among the various disintegration paths and in particular the isospin effects on the decay modes of the produced composite systems are investigated; this provides information about fundamental nuclear quantities such as level density, fission barrier and viscosity. Different isotopic composition and relative richness are observed among the reaction products of the two systems. An odd-even staggering effect is present in the charge distributions, in particular for the light fragments produced by the neutron-poor system. The kinematical characteristics of the IMF seem to indicate a high degree of the relaxation of the formed system. Besides, global features analysis seems to show some differences in the contribution arising from the various reaction mechanisms for the two reactions.

  20. A single episode of high intensity sound inhibits long-term potentiation in the hippocampus of rats.

    Science.gov (United States)

    de Deus, J L; Cunha, A O S; Terzian, A L; Resstel, L B; Elias, L L K; Antunes-Rodrigues, J; Almeida, S S; Leão, R M

    2017-10-26

    Exposure to loud sounds has become increasingly common. The most common consequences of loud sound exposure are deafness and tinnitus, but emotional and cognitive problems are also associated with loud sound exposure. Loud sounds can activate the hipothalamic-pituitary-adrenal axis resulting in the secretion of corticosterone, which affects hippocampal synaptic plasticity. Previously we have shown that long-term exposure to short episodes of high intensity sound inhibited hippocampal long-term potentiation (LTP) without affecting spatial learning and memory. Here we aimed to study the impact of short term loud sound exposure on hippocampal synaptic plasticity and function. We found that a single minute of 110 dB sound inhibits hippocampal Schaffer-CA1 LTP for 24 hours. This effect did not occur with an 80-dB sound exposure, was not correlated with corticosterone secretion and was also observed in the perforant-dentate gyrus synapse. We found that despite the deficit in the LTP these animals presented normal spatial learning and memory and fear conditioning. We conclude that a single episode of high-intensity sound impairs hippocampal LTP, without impairing memory and learning. Our results show that the hippocampus is very responsive to loud sounds which can have a potential, but not yet identified, impact on its function.

  1. Effects of High-Intensity Intermittent Training on Vascular Function in Obese Preadolescent Boys.

    Science.gov (United States)

    Chuensiri, Napasakorn; Suksom, Daroonwan; Tanaka, Hirofumi

    2018-01-01

    High-intensity intermittent training (HIIT) may serve as an effective alternative to traditional endurance training, since HIIT has been shown to induce greater improvements in aerobic fitness and health-related markers in adult populations. Our objective was to determine whether HIIT and supramaximal high-intensity intermittent training (supra-HIIT) would improve vascular structure and function in obese preadolescent boys. Before the baseline testing, 48 obese preadolescent boys, aged 8-12 years, were randomly assigned into control (CON; n = 16), HIIT (8 × 2 minutes at 90% peak power output, n = 16), and supra-HIIT (8 × 20 seconds at 170% peak power output, n = 16) groups. Both exercise groups performed exercises on a cycle ergometer three times/week for 12 weeks. After 12 weeks, both HIIT and supra-HIIT did not affect body mass, body fat percentage, and waist circumference. Peak oxygen consumption (VO 2 peak) increased in both HIIT and supra-HIIT groups (p HIIT and supra-HIIT groups had higher resting metabolic rate than the control group (p HIIT and supra-HIIT program (all p HIIT and supra-HIIT groups (all p HIIT and supra-HIIT have favorable effects on aerobic capacity, metabolic rate, vascular function and structure, and blood lipid profile in obese preadolescent boys. HIIT may be a time efficient and effective exercise for preventing future cardiovascular disease in obese children.

  2. A Close Association of RyRs with Highly Dense Clusters of Ca2+-activated Cl− Channels Underlies the Activation of STICs by Ca2+ Sparks in Mouse Airway Smooth Muscle

    Science.gov (United States)

    Bao, Rongfeng; Lifshitz, Lawrence M.; Tuft, Richard A.; Bellvé, Karl; Fogarty, Kevin E.; ZhuGe, Ronghua

    2008-01-01

    Ca2+ sparks are highly localized, transient releases of Ca2+ from sarcoplasmic reticulum through ryanodine receptors (RyRs). In smooth muscle, Ca2+ sparks trigger spontaneous transient outward currents (STOCs) by opening nearby clusters of large-conductance Ca2+-activated K+ channels, and also gate Ca2+-activated Cl− (Cl(Ca)) channels to induce spontaneous transient inward currents (STICs). While the molecular mechanisms underlying the activation of STOCs by Ca2+ sparks is well understood, little information is available on how Ca2+ sparks activate STICs. In the present study, we investigated the spatial organization of RyRs and Cl(Ca) channels in spark sites in airway myocytes from mouse. Ca2+ sparks and STICs were simultaneously recorded, respectively, with high-speed, widefield digital microscopy and whole-cell patch-clamp. An image-based approach was applied to measure the Ca2+ current underlying a Ca2+ spark (ICa(spark)), with an appropriate correction for endogenous fixed Ca2+ buffer, which was characterized by flash photolysis of NPEGTA. We found that ICa(spark) rises to a peak in 9 ms and decays with a single exponential with a time constant of 12 ms, suggesting that Ca2+ sparks result from the nonsimultaneous opening and closure of multiple RyRs. The onset of the STIC lags the onset of the ICa(spark) by less than 3 ms, and its rising phase matches the duration of the ICa(spark). We further determined that Cl(Ca) channels on average are exposed to a [Ca2+] of 2.4 μM or greater during Ca2+ sparks. The area of the plasma membrane reaching this level is <600 nm in radius, as revealed by the spatiotemporal profile of [Ca2+] produced by a reaction-diffusion simulation with measured ICa(spark). Finally we estimated that the number of Cl(Ca) channels localized in Ca2+ spark sites could account for all the Cl(Ca) channels in the entire cell. Taken together these results lead us to propose a model in which RyRs and Cl(Ca) channels in Ca2+ spark sites localize

  3. Clinical value of multi-tumor markers detection with (CEA, CA19-9, CA72-4) for diagnosis of gastric malignancy

    International Nuclear Information System (INIS)

    Liu Yun; Li Jiangang

    2007-01-01

    Objective: To assess the clinical value of multi-tumor markers detection with (CEA, CA19-9, CA72-4) for diagnosis of gastric malignancy. Methods: Serum CEA, CA19-9, CA72-4 contents were measured with IRMA in 228 patients with gastric malignancies, 152 patients with benign gastric disorders and 200 controls. Results: The positive rates of single marker detection were all above 70% and that of CA72-4 was the highest (84.21%), next was CA19-9 (75.43%). Three tumor markers were all negative in only 4 cases (false negative rate was 1.75% ). So combined detection of 3 tumor markers could improve the positive rate to 98.25%. With combined determination of two markers, double positive rate for different sets of combinations was: 61.84% for CA72-4 + CA19-9, 51.31% for CA72-4 + CEA and 48.24% for CEA + CA19-9. Conclusion: It was suggested that for screening, CA72-4 was the first choice in single marker detections, and CA72-4 + CA19-9 was the first choice for combined detections of two markers. For follow-up, a combination of 2 markers with highest positive rate for the specific histopathologic type (i. e. carcinoma, leiomyosarcoma or lymphosarcoma) should be used throughout the study. (authors)

  4. High-intensity resistance and cardiovascular training improve physical capacity in cancer patients undergoing chemotherapy

    DEFF Research Database (Denmark)

    Quist, Morten; Rørth, Mikael Rahbek; Zacho, Morten

    2006-01-01

    The purpose of the study was to examine the effects of a supervised high- and low-intensity structured training program in cancer patients concurrently undergoing chemotherapy. Seventy patients, in different stages of the disease and with different diagnoses (48 females, 22 males), between 18...... and 65 years of age (mean age 42.8) participated in a 9-h weekly training program over 6 weeks. The intervention involved physical exercise, relaxation, massage, and body-awareness training. Physical capacity (one-repetition maximum tests (1RM), VO2max) and body composition (weight, skin-fold) were......-term study support the theory that exercise is a beneficial intervention strategy for increasing muscle strength and aerobic fitness during antineoplastic chemotherapy. This type of exercise program can be an important component of complementary treatment for cancer patients undergoing chemotherapy....

  5. Optimization and application of ICPMS with dynamic reaction cell for precise determination of 44Ca/40Ca isotope ratios.

    Science.gov (United States)

    Boulyga, Sergei F; Klötzli, Urs; Stingeder, Gerhard; Prohaska, Thomas

    2007-10-15

    An inductively coupled plasma mass spectrometer with dynamic reaction cell (ICP-DRC-MS) was optimized for determining (44)Ca/(40)Ca isotope ratios in aqueous solutions with respect to (i) repeatability, (ii) robustness, and (iii) stability. Ammonia as reaction gas allowed both the removal of (40)Ar+ interference on (40)Ca+ and collisional damping of ion density fluctuations of an ion beam extracted from an ICP. The effect of laboratory conditions as well as ICP-DRC-MS parameters such a nebulizer gas flow rate, rf power, lens potential, dwell time, or DRC parameters on precision and mass bias was studied. Precision (calculated using the "unbiased" or "n - 1" method) of a single isotope ratio measurement of a 60 ng g(-1) calcium solution (analysis time of 6 min) is routinely achievable in the range of 0.03-0.05%, which corresponded to the standard error of the mean value (n = 6) of 0.012-0.020%. These experimentally observed RSDs were close to theoretical precision values given by counting statistics. Accuracy of measured isotope ratios was assessed by comparative measurements of the same samples by ICP-DRC-MS and thermal ionization mass spectrometry (TIMS) by using isotope dilution with a (43)Ca-(48)Ca double spike. The analysis time in both cases was 1 h per analysis (10 blocks, each 6 min). The delta(44)Ca values measured by TIMS and ICP-DRC-MS with double-spike calibration in two samples (Ca ICP standard solution and digested NIST 1486 bone meal) coincided within the obtained precision. Although the applied isotope dilution with (43)Ca-(48)Ca double-spike compensates for time-dependent deviations of mass bias and allows achieving accurate results, this approach makes it necessary to measure an additional isotope pair, reducing the overall analysis time per isotope or increasing the total analysis time. Further development of external calibration by using a bracketing method would allow a wider use of ICP-DRC-MS for routine calcium isotopic measurements, but it

  6. High-pressure crystal growth and electromagnetic properties of 5d double-perovskite Ca3OsO6

    International Nuclear Information System (INIS)

    Feng, Hai Luke; Shi, Youguo; Guo, Yanfeng; Li, Jun; Sato, Akira; Sun, Ying; Wang, Xia; Yu, Shan; Sathish, Clastin I.; Yamaura, Kazunari

    2013-01-01

    Single crystals of the osmium-containing compound Ca 3 OsO 6 have been successfully grown under high-pressure conditions, for the first time. The crystal structure of Ca 3 OsO 6 were characterized as an ordered double-perovskite structure of space group P2 1 /n with the Ca and Os atoms being fully ordered at the perovskite B-site. The electromagnetic analysis shows that the crystal exhibits a semiconductor-like behavior below 300 K and undergoes an antiferromagnetic transition at 50 K. - Graphical Abstract: Schematic image of crystal structure of Ca 3 OsO 6 as determined by X-ray diffraction, where the gray and black octahedrons are occupied by Ca and Os, respectively. Top inset reveals an optic image of a typical Ca 3 OsO 6 single crystal. Highlights: ► Single crystals of Ca 3 OsO 6 have been successfully grown under high-pressure. ► Ca 3 OsO 6 crystalizes into an ordered double-perovskite structure. ► The Ca 3 OsO 6 undergoes an antiferromagnetic transition at 50 K

  7. Phase controlled synthesis of (Mg, Ca, Ba)-ferrite magnetic nanoparticles with high uniformity

    International Nuclear Information System (INIS)

    Wang, S.F.; Li, Q.; Zu, X.T.; Xiang, X.; Liu, W.; Li, S.

    2016-01-01

    (Mg, Ca, Ba)-ferrite magnetic nanoparticles were successfully synthesized through modifying the atomic ratio of polysaccharide and chelating agent at an optimal sintering temperature. In the process, the polysaccharide plays an important role in drastically shrinking the precursor during the gel drying process. In the metal-complex structure, M"2"+ ion active sites were coordinated by −OH of the water molecules except for EDTA anions. The MFe_2O_4 magnetic nanoparticles exhibited enhanced magnetic properties when compared with nano-MFe_2O_4 of similar particle size synthesized by other synthesis route reported in the literature. In particular, the sintering temperature improves the crystallinity and increases the hysteresis loop squareness ratio of (Mg, Ca, Ba)-ferrite nanoparticles significantly. - Graphical abstract: Schematic representation of the proposed model for MFe_2O_4 nanoparticle synthesis, starting from EDTA-chelated M"2"+ (M=Mg, Ca, or Ba) cations (left). High dispersion (Mg, Ca, Ba)-ferrite magnetic nanoparticles were prepared by a modified polyacrylamide gel route. Optimized utilization of polysaccharide, chelating agent, and sintering temperature allowed the formation of (Mg, Ca, Ba)-ferrite nanoparticles with a narrow diameter distribution. - Highlights: • We report a modified polyacrylamide gel route to synthesize (Mg, Ca, Ba)-ferrite magnetic nanoparticles. • Chelate mechanism of metal ions (Mg, Ca, Ba) and EDTA has been discussed. • Phase transformation process of (Mg, Ca, Ba)-ferrites has been discussed. • The preparation method increases the hysteresis loop squareness ratio of (Mg, Ca, Ba)-ferrite nanoparticles.

  8. Correlation of histological examination of meniscus with MR images; Focused on high signal intensity of the meniscus not caused by definite meniscal tear and impact on MR diagnosis of tears

    Energy Technology Data Exchange (ETDEWEB)

    Li, Chun Ai; Kim, Min Ki; Kim, In Hwan; Lee, Ju Hong; Jang, Kyu Yun; Lee, Sang Yong [Chonbuk National University Hospital, Chonbuk National University College of Medicine, Jeonju (Korea, Republic of)

    2013-12-15

    To document the causes of high signal intensity of the meniscus which is not caused by definite meniscal tears on MR imaging, through correlation with histological examination. For the correlation between the MR image and histology, we obtained prospectively 31 meniscal specimens from 21 patients. Proton density-weighted turbo spin-echo MR images were used. Minimal tear, thinning of the lamellar layer, degeneration of the central layer, and radial tie fibers were detected upon histological examination, and were correlated with the corresponding MR images. Minimal tear of the lamellar layer was seen in 60 zones out of 100 slides. On MR images, 29 (48.3%) of these 60 zones had high signal intensity. Thinning of the lamellar layer was seen in 24 zones, with 7 (29.2%) having high signal intensity. 57 central zones showed degenerative change in the central layer and high signal intensity on all corresponding MR images. Radial tie fibers in the central layer appeared as high signal intensity areas. Minimal tear and thinning of the lamellar layer, degeneration and radial tie fibers of the central layer of the meniscus cause high signal intensity on MR images.

  9. The causes of the high energy intensity of the Kazakh economy: A characterization of its energy system

    International Nuclear Information System (INIS)

    Gómez, Antonio; Dopazo, César; Fueyo, Norberto

    2014-01-01

    The primary energy intensity of Kazakhstan is among the highest in the world. The aim of this paper is to explore, in a quantitative way, the reasons for this condition, and to highlight the opportunities for improvement. To do so, we have developed a detailed ‘bottom-up’ model of the Kazakh energy sector. With this model, we have calculated the potential energy savings on both the demand and supply sides, and for all the economy sectors. This potential is defined as the difference between the current energy consumption in each sector/activity and the energy consumption if best available technologies or energy efficiency standards prevailing in developed countries were adopted in Kazakhstan. We conclude that the main causes of the energy inefficiency in Kazakhstan are: the excessive energy demand of buildings (especially for space heating) in the household and service sector, the inefficiency of the industry sector, particularly in the iron and steel and non-ferrous metals subsectors, the obsolescence of the heating and power generation assets, and the inefficient management of associated gas (flaring and re-injection in oil wells). With current energy efficiency standards prevailing in developed countries, the primary energy consumption in Kazakhstan in 2010 would be reduced by 48.6%, from 75.4 to 38.7 Mtoe. - Highlights: • A detailed ‘bottom-up’ model of the Kazakh energy sector has been developed. • The reasons of the high primary energy intensity of Kazakhstan are determined. • Household and industrial sectors of Kazakhstan are highly inefficient. • Associated gas management shows the highest potential for energy saving. • Primary energy consumption would be reduced by 48.6% with the proposed measures

  10. Effect of flux on the composition and luminescent properties of Ca{sub 0.68}Mg{sub 0.2}SiO{sub 3}:0.12Eu{sup 3+} red phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jin shan [College of Material Science and Engineering, Sichuan University, Chengdu 610065, Sichuan (China); Zhu, Da-chuan, E-mail: zdc89@163.com [College of Material Science and Engineering, Sichuan University, Chengdu 610065, Sichuan (China); Zheng, Qi [College of Material Science and Engineering, Sichuan University, Chengdu 610065, Sichuan (China); Han, Tao [Research Institute for New Materials Technology, Chongqing University of Arts and Sciences, Yongchuan 402160, Chongqing (China)

    2016-11-15

    Ca{sub 0.68}Mg{sub 0.2}SiO{sub 3}:0.12Eu{sup 3+} red-emitting phosphor was synthesized via one-step calcination process of the precursor prepared by chemical coprecipitation with different fluxes. Then X-ray diffraction and fluorescence spectrophotometry were adopted to investigate the structure and luminescent properties of Ca{sub 0.68}Mg{sub 0.2}SiO{sub 3}:0.12Eu{sup 3+}. The results indicated that adding fluxes increased the crystalline significantly while the phase composition of samples was not changed. Furthermore, the fluxes improved the intensity of emission peak and the quantum efficiency greatly. With the concentration of flux (Li{sub 2}CO{sub 3} or K{sub 2}CO{sub 3}) increasing, the emission intensity of Ca{sub 0.68}Mg{sub 0.2}SiO{sub 3}:0.12Eu{sup 3+} firstly increased and then decreased. Meanwhile, red-shift phenomenon was observed in the emission spectra. The optimal adding fraction of Li{sub 2}CO{sub 3} and K{sub 2}CO{sub 3} was 6% and 5% respectively, and the luminous intensity of samples calcined with the optimum adding amount of Li{sub 2}CO{sub 3}, K{sub 2}CO{sub 3} is 42 and 48 times that of the samples without flux. K{sub 2}CO{sub 3} showed a better effect on improving the emission intensity of the phosphors than Li{sub 2}CO{sub 3}.

  11. [Ca2+]i in exterior of cells effected on apoptosis of HL-60 cells induced by irradiation

    International Nuclear Information System (INIS)

    He Ziyi; Meng Qingyong

    2005-01-01

    Objective: To investigate of the different [Ca 2+ ]i in exterior of cells promotion function on apoptosis of HL-60 cells induced by irradiation. Methods: To put ration dose 32 P and different [Ca 2+ ]i into culture of HL-60 and measure the apoptosis rate with FCM after 24 and 48 hours. Result: Apoptosis rate increased with the increase of [Ca 2+ ]i which shows an obvious function to promote apoptosis, r 24 =0.9001 (P=0.0145); r48=0.9343 (P=0.0063). Conclusion: [Ca 2+ ]i in exterior of cells has a obvious function in promoteing apoptosis induced by irradiation. (authors)

  12. Sr/Ca and Mg/Ca in Glycymeris glycymeris (Bivalvia) shells from the Iberian upwelling system: Ontogeny and environmental control

    Science.gov (United States)

    Freitas, Pedro; Richardson, Christopher; Chenery, Simon; Monteiro, Carlos; Butler, Paul; Reynolds, David; Scourse, James; Gaspar, Miguel

    2017-04-01

    Bivalve shells have a great potential as high-resolution geochemical proxy archives of marine environmental conditions. In addition, sclerochronology of long-lived bivalve species (e.g. Arctica islandica) provides a timeline of absolutely dated shell material for geochemical analysis that can extend into the past beyond the lifetime of single individuals through the use of replicated crossmatched centennial to millennial chronologies. However, the interpretation of such records remains extremely challenging and complex, with multiple environmental and biological processes affecting element incorporation in the shell (e.g. crystal fabrics, organic matrix, biomineralization mechanisms and physiological processes). As a result, the effective use of bivalve shell elemental/Ca ratios as palaeoenvironmental proxies has been limited, often to species-specific applications or applications restricted to particular environmental settings. The dog-cockle, Glycymeris glycymeris, is a relatively long-lived bivalve (up to 200 years) that occurs in coarse-grained subtidal sediments of coastal shelf seas of Europe and North West Africa. Glycymeris glycymeris shells provide a valuable, albeit not fully explored, archive to reconstruct past environmental variability in an area lacking sclerochronological studies due to the rarity of long-lived bivalves and lack of coral reefs. In this study, we evaluate the potential of Sr/Ca and Mg/Ca ratios in G. glycymeris shells as geochemical proxies of upwelling conditions in the Iberian Upwelling System, the northern section of the Canary Current Eastern Boundary Upwelling System. Sr/Ca and Mg/Ca generally co-varied significantly and a clear ontogenetic, non-environmental related change in Sr/Ca and Ba/Ca variability was observed. High Sr/Ca and Mg/Ca ratios in older shells (> 10 years old) were found to be associated with the occurrence of growth lines deposited during the winter reduction in shell growth. Nevertheless, Sr/Ca and Mg/Ca

  13. Effect of Ca and Y additions on oxidation behavior of magnesium alloys at high temperatures

    Institute of Scientific and Technical Information of China (English)

    FAN Jianfeng; YANG Changlin; XU Bingshe

    2012-01-01

    Oxidation and ignition of magnesium alloys at elevated temperature were successfully retarded by additions of Y and Ca.which could be melted at 1173 K in air without any protection.Thermogravimetric measurements in dry air revealed that the oxidation dynamics curves of Mg-2.5Ca alloy and Mg-3.5Y-0.79Ca alloy at high temperatures followed the parabolic-line law or the ubic-line law.X-ray diffraction (XRD) and scanning electron microscopy (SEM) analysis indicated that the oxide film on the surface of Mg-3.5Y-0.79Ca and Mg-2.5Ca alloys exhibited a duplex structure.which agreed with the results of thermodynamic analysis.By comparison,the ignition-proof effect of the combination addition of Y and Ca was better than that of the single addition of Ca.

  14. Beam halo in high-intensity hadron linacs

    Energy Technology Data Exchange (ETDEWEB)

    Gerigk, F

    2006-12-21

    This document aims to cover the most relevant mechanisms for the development of beam halo in high-intensity hadron linacs. The introduction outlines the various applications of high-intensity linacs and it will explain why, in the case of the CERN Superconducting Proton Linac (SPL) study a linac was chosen to provide a high-power beam, rather than a different kind of accelerator. The basic equations, needed for the understanding of halo development are derived and employed to study the effects of initial and distributed mismatch on high-current beams. The basic concepts of the particle-core model, envelope modes, parametric resonances, the free-energy approach, and the idea of core-core resonances are introduced and extended to study beams in realistic linac lattices. The approach taken is to study the behavior of beams not only in simplified theoretical focusing structures but to highlight the beam dynamics in realistic accelerators. All effects which are described and derived with simplified analytic models, are tested in realistic lattices and are thus related to observable effects in linear accelerators. This approach involves the use of high-performance particle tracking codes, which are needed to simulate the behavior of the outermost particles in distributions of up to 100 million macro particles. In the end a set of design rules are established and their impact on the design of a typical high-intensity machine, the CERN SPL, is shown. The examples given in this document refer to two different design evolutions of the SPL study: the first conceptual design report (SPL I) and the second conceptual design report (SPL II). (orig.)

  15. Modelling Ca2+ bound Troponin in Excitation Contraction Coupling

    Directory of Open Access Journals (Sweden)

    Henry G. Zot

    2016-09-01

    Full Text Available To explain disparate decay rates of cytosolic Ca2+ and structural changes in the thin filaments during a twitch, we model the time course of Ca2+ bound troponin (Tn resulting from the free Ca2+ transient of fast skeletal muscle. In fibers stretched beyond overlap, the decay of Ca2+ as measured by a change in fluo 3 fluorescence is significantly slower than the intensity decay of the meridional 1/38.5 nm-1 reflection of Tn; this is not simply explained by considering only the Ca2+ binding properties of Tn alone (Matsuo, T., Iwamoto, H., and Yagi, N. (2010. Biophys. J. 99, 193-200. We apply a comprehensive model that includes the known Ca2+ binding properties of Tn in the context of the thin filament with and without cycling crossbridges. Calculations based on the model predict that the transient of Ca2+ bound Tn correlates with either the fluo 3 time course in muscle with overlapping thin and thick filaments or the intensity of the meridional 1/38.5 nm-1 reflection in overstretched muscle. Hence, cycling crossbridges delay the dissociation of Ca2+ from Tn. Correlation with the fluo 3 fluorescence change is not causal given that the transient of Ca2+ bound Tn depends on sarcomere length, whereas the fluo-3 fluorescence change does not. Transient positions of tropomyosin calculated from the time course of Ca2+ bound Tn are in reasonable agreement with the transient of measured perturbations of the Tn repeat in overlap and non-overlap muscle preparations.

  16. High intensity discharge device containing oxytrihalides

    Science.gov (United States)

    Lapatovich, W.P.; Keeffe, W.M.; Liebermann, R.W.; Maya, J.

    1987-06-09

    A fill composition for a high intensity discharge device including mercury, niobium oxytrihalide, and a molecular stabilization agent is provided. The molar ratio of niobium oxytrihalide to the molecular stabilization agent in the fill is in the range of from about 5:1 to about 7.5:1. Niobium oxytrihalide is present in the fill in sufficient amount to produce, by dissociation in the discharge, atomic niobium, niobium oxide, NbO, and niobium dioxide, NbO[sub 2], with the molar ratio of niobium-containing vapor species to mercury in the fill being in the range of from about 0.01:1 to about 0.50:1; and mercury pressure of about 1 to about 50 atmospheres at lamp operating temperature. There is also provided a high intensity discharge device comprising a sealed light-transmissive arc tube; the arc tube including the above-described fill; and an energizing means for producing an electric discharge within the arc tube. 7 figs.

  17. Einstein A coefficients for rovibronic lines of the A2Π → X2Σ+ and B2Σ+ → X2Σ+ transitions of CaH and CaD

    Science.gov (United States)

    Alavi, S. Fatemeh; Shayesteh, Alireza

    2018-02-01

    Calcium monohydride is an important diatomic molecule appearing in the spectra of sunspots and M dwarfs. We report complete line lists with Einstein A coefficients for the A2Π-X2Σ+ and B2Σ+-X2Σ+ electronic transitions of CaH and CaD radicals. The most recent ab initio transition dipole moments and potential energy curves were used for the calculation of vibronic band intensities, taking the Herman-Wallis effect into account, and the rotational line strengths were calculated using the PGOPHER program of Western. For the A2Π and B2Σ+ excited states of CaH and CaD, new off-diagonal electronic matrix elements were included in the Hamiltonian matrix, and new sets of spectroscopic constants were determined in order to accurately reproduce the line positions and relative intensities of the observed branches in laboratory spectra. For both CaH and CaD isotopologues, Einstein A coefficients were calculated for all possible rovibronic transitions from the v΄ = 0-3 vibrational levels of the A2Π state and the v΄ = 0-2 vibrational levels of the B2Σ+ state to the v″ = 0-4 vibrational levels of the X2Σ+ ground state. The line lists and intensities reported here can be used to accurately determine the amounts of CaH and CaD in stellar environments.

  18. Comparison of Two Intensities of Aerobic Training (low intensity and High Intensity on Expression of Perlipin 2 Skeletal Muscle, Serum Glucose and Insulin levels in Streptozotocin-Diabetic Rats

    Directory of Open Access Journals (Sweden)

    M Ghafari

    2017-06-01

    Full Text Available Abstract   Background & aim: Lipid metabolism disorder plays an important role in insulin resistance in skeletal muscle and lipid drop proteins such as perlipine 2 (PLIN2 are effective in regulating intracellular fat metabolism. One of the suggested pathways for the effects of endurance activity in metabolic diseases is the effect of physical activity on intramuscular. Therefore, the purpose of this study was compare the intensity of aerobic exercise intensity (low intensity and high intensity on expression of PLIN2 skeletal muscle, serum glucose and insulin levels in streptozotocin-diabetic rats.   Methods: In this experimental study, 24 male Wistar rats were randomly divided into three groups of 8, including two intervention groups (low intensity endurance training group and high intensity continuous exercise group and one control group. After induction of diabetic rats by injection streptozotocin (55 mg / kg body weight, Intraperitoneally, endurance training was applied for eight weeks, three sessions per week in diabetic rats. Exercise intensity in the low-intensity group was equal to 5-8 m / min (equivalent to 50-60% Vo2max, the intensity of training in a high intensity training group was equivalent to a speed of 22-25 m / min (equivalent to 80% Vo2max and the control group did not receive intervene in this time. Relative protein expression of PLIN2 was performed using western blot technique. Data were analyzed by one-way ANOVA and Tukey's post hoc test.   Results: The results of the intergroup comparison revealed a significant difference among three groups in the PLIN2 variables (p = 0.037. The results of post hoc test showed a significant increase in PLIN2 in high intensity training diabetic group compared to the control group (p = 0.033 However, there was no significant difference in PLIN2 level in the low exercise group compared to the control group (p = 0.18. Also, there was no significant difference between the low intensity and

  19. Phase controlled synthesis of (Mg, Ca, Ba)-ferrite magnetic nanoparticles with high uniformity

    Energy Technology Data Exchange (ETDEWEB)

    Wang, S.F., E-mail: wangshifa2006@yeah.net [School of Physical Electronics, University of Electronic Science and Technology of China, Chengdu 610054, Sichuan (China); Science and technology on vacuum technology and physics laboratory, Lanzhou Institute of Physics, Lanzhou 730000, Gansu (China); Li, Q. [School of Physical Electronics, University of Electronic Science and Technology of China, Chengdu 610054, Sichuan (China); Zu, X.T., E-mail: xtzu@uestc.edu.cn [Institute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu 610054, Sichuan (China); Xiang, X.; Liu, W. [School of Physical Electronics, University of Electronic Science and Technology of China, Chengdu 610054, Sichuan (China); Li, S., E-mail: sean.li@unsw.edu.au [School of Material Science and Engineering, University of New South Wales, Sydney 2052 (Australia)

    2016-12-01

    (Mg, Ca, Ba)-ferrite magnetic nanoparticles were successfully synthesized through modifying the atomic ratio of polysaccharide and chelating agent at an optimal sintering temperature. In the process, the polysaccharide plays an important role in drastically shrinking the precursor during the gel drying process. In the metal-complex structure, M{sup 2+} ion active sites were coordinated by −OH of the water molecules except for EDTA anions. The MFe{sub 2}O{sub 4} magnetic nanoparticles exhibited enhanced magnetic properties when compared with nano-MFe{sub 2}O{sub 4} of similar particle size synthesized by other synthesis route reported in the literature. In particular, the sintering temperature improves the crystallinity and increases the hysteresis loop squareness ratio of (Mg, Ca, Ba)-ferrite nanoparticles significantly. - Graphical abstract: Schematic representation of the proposed model for MFe{sub 2}O{sub 4} nanoparticle synthesis, starting from EDTA-chelated M{sup 2+} (M=Mg, Ca, or Ba) cations (left). High dispersion (Mg, Ca, Ba)-ferrite magnetic nanoparticles were prepared by a modified polyacrylamide gel route. Optimized utilization of polysaccharide, chelating agent, and sintering temperature allowed the formation of (Mg, Ca, Ba)-ferrite nanoparticles with a narrow diameter distribution. - Highlights: • We report a modified polyacrylamide gel route to synthesize (Mg, Ca, Ba)-ferrite magnetic nanoparticles. • Chelate mechanism of metal ions (Mg, Ca, Ba) and EDTA has been discussed. • Phase transformation process of (Mg, Ca, Ba)-ferrites has been discussed. • The preparation method increases the hysteresis loop squareness ratio of (Mg, Ca, Ba)-ferrite nanoparticles.

  20. [Analysis of the intensity of professional collaboration among nurses in a critical care area].

    Science.gov (United States)

    Bengoechea Calpe, L; Marín Fernández, B; Regaira Martínez, E

    2016-01-01

    To analyse the intensity of professional collaboration (IPC) between the nurses in a multidisciplinary critical area (CA) and the relationship with the workplace "intensive care unit (ICU) and special hospitalisation area (SHA)", educational level, age, and years of professional activity in CA. A cross-sectional descriptive study was conducted with 57 nurses from CA, recording socio-demographic data: age, educational level, speciality titles, years of professional activity and workday type, years of professional activity in the CA, and involvement in scientific works. Tool: Intensity of Inter-professional Collaboration Questionnaire. SPSS 20.0. The study included a total of 47 nurses (ICU/SHA), with a mean age of 35.91 (9.59) years. Almost three-quarters (74.46%) were nursing graduates with a posgraduate in ICU. Median and interquartile range of professional experience was 14 and 14.50 years, respectively, and years working in CA was 8.50 and 16 years, respectively. Just over half of them (51.10%) worked part-time, and 61.70% participated in scientific works. The mean IPC score was 61.68 (6.84), with 57.40% providing values of high IPC. The relationship between the workplace (ICU/SHA) and educational level with IPC was not statistically significant (p>.05). There are statistical significant differences between IPC with age and years of professional activity in CA (p<.05). The present study demonstrates the existence of good IPC in the CA. Younger nurses obtain a better IPC score, as well as nurses who have been working for less time in CA. Nurses with a Degree or Masters have a higher level of IPC than the rest, as well as nurses who perform professional activity combining ICU and SHA. Copyright © 2015 Elsevier España, S.L.U. y SEEIUC. All rights reserved.

  1. Inactivation of Ca2+-induced ciliary reversal by high-salt extraction in the cilia of Paramecium.

    Science.gov (United States)

    Kutomi, Osamu; Seki, Makoto; Nakamura, Shogo; Kamachi, Hiroyuki; Noguchi, Munenori

    2013-10-01

    Intracellular Ca(2+) induces ciliary reversal and backward swimming in Paramecium. However, it is not known how the Ca(2+) signal controls the motor machinery to induce ciliary reversal. We found that demembranated cilia on the ciliated cortical sheets from Paramecium caudatum lost the ability to undergo ciliary reversal after brief extraction with a solution containing 0.5 M KCl. KNO(3), which is similar to KCl with respect to chaotropic effect; it had the same effect as that of KCl on ciliary response. Cyclic AMP antagonizes Ca(2+)-induced ciliary reversal. Limited trypsin digestion prevents endogenous A-kinase and cAMP-dependent phosphorylation of an outer arm dynein light chain and induces ciliary reversal. However, the trypsin digestion prior to the high-salt extraction did not affect the inhibition of Ca(2+)-induced ciliary reversal caused by the high-salt extraction. Furthermore, during the course of the high-salt extraction, some axonemal proteins were extracted from ciliary axonemes, suggesting that they may be responsible for Ca(2+)-induced ciliary reversal.

  2. Eleven new heaviest isotopes of elements Z=105 to Z=117 identified among the products of 249Bk+48Ca reactions

    International Nuclear Information System (INIS)

    Oganessian, Yu. Ts.; Abdullin, F. Sh.; Dmitriev, S. N.; Itkis, M. G.; Lobanov, Yu. V.; Mezentsev, A. N.; Polyakov, A. N.; Sagaidak, R. N.; Shirokovsky, I. V.; Subbotin, V. G.; Sukhov, A. M.; Tsyganov, Yu. S.; Utyonkov, V. K.; Voinov, A. A.; Vostokin, G. K.; Bailey, P. D.; Benker, D. E.; Ezold, J. G.; Porter, C. E.; Riley, F. D.

    2011-01-01

    The heaviest isotopes of elements Z=117 to Z=105, 294 117, 293 117, 290 115, 289 115, 286 113, 285 113, 282 Rg, 281 Rg, 278 Mt, 274 Bh, and 270 Db, were identified by means of the Dubna gas-filled recoil separator among the products of the 249 Bk + 48 Ca reaction. The details of the observed six decay chains, indicating the production and decay of isotopes 293 117 and 294 117, are presented and discussed. The decay energies and resulting half-lives of these new nuclei show a strong rise of stability with increasing neutron number, validating the concept of the island of enhanced stability for superheavy nuclei [Oganessian et al., Phys. Rev. Lett. 104, 142502 (2010)].

  3. Determination of Mg/Ca ratio of stalagmite by laser multicollector inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    He Xuexian; Zhu Xiangkun; Tang Suohan; Yang Chun; Cai Junjun; Li Shizhen; Li Zhihong

    2005-01-01

    A method for determining Mg/Ca of stalagmite by LA-MC-ICPMS is studied. 24 Mg/ 44 Ca (Mass 22, intensity of 44C a 2+ , collected by ion counting and mass 24, intensity of 24 Mg + , collected by Faraday cup) ratios were measured in replace of Mg/Ca ratios. Both diameter of laser sampling spot and laser moving increment were 2- μm. The curve of Mg/Ca vs. distance directly was obtained. The result indicates that relative Mg/Ca ratios changed from 0.5 to 2.0 this stalagmite and it is enough to reflect environmental factors act. (authors)

  4. Gaussian representation of high-intensity focused ultrasound beams.

    Science.gov (United States)

    Soneson, Joshua E; Myers, Matthew R

    2007-11-01

    A method for fast numerical simulation of high-intensity focused ultrasound beams is derived. The method is based on the frequency-domain representation of the Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation, and assumes for each harmonic a Gaussian transverse pressure distribution at all distances from the transducer face. The beamwidths of the harmonics are constrained to vary inversely with the square root of the harmonic number, and as such this method may be viewed as an extension of a quasilinear approximation. The technique is capable of determining pressure or intensity fields of moderately nonlinear high-intensity focused ultrasound beams in water or biological tissue, usually requiring less than a minute of computer time on a modern workstation. Moreover, this method is particularly well suited to high-gain simulations since, unlike traditional finite-difference methods, it is not subject to resolution limitations in the transverse direction. Results are shown to be in reasonable agreement with numerical solutions of the full KZK equation in both tissue and water for moderately nonlinear beams.

  5. Regulation of Ca2+ influx by a protein kinase C activator in chromaffin cells: differential role of P/Q- and L-type Ca2+ channels.

    Science.gov (United States)

    Sena, C M; Santos, R M; Boarder, M R; Rosário, L M

    1999-02-05

    Phorbol esters reduce depolarization-evoked Ca2+ influx in adrenal chromaffin cells, suggesting that voltage-sensitive Ca2+ channels (VSCCs) are inhibited by protein kinase C-mediated phosphorylation. We now address the possibility that L- and P/Q-type Ca2+ channel subtypes might be differentially involved in phorbol ester action. In bovine chromaffin cells, short-term (10 min) incubations with phorbol 12-myristate 13-acetate (PMA) inhibited early high K+-evoked rises in cytosolic free Ca2+ concentration ([Ca2+]i) and the early component of the depolarization-evoked Mn2+ quenching of fura-2 fluorescence in a dose-dependent manner (IC50: 18 and 7 nM; maximal inhibitions: 45 and 48%, respectively). The protein kinase C inhibitor staurosporine (100 nM) reverted the inhibitory action of PMA. PMA (0.1-1 microM) inhibited the early and late phases of the ionomycin (2 microM)-evoked [Ca2+]i transients by 14-23%. Omega-agatoxin IVA, a blocker of P/Q-type Ca2+ channels, inhibited high K+-evoked [Ca2+]i rises in a dose-dependent fashion (IC50 = 50 nM). In contrast, 0.1 microM omega-conotoxin GVIA, a blocker of N-type channels, was without effect. A sizeable (< 45%) component of early Ca2+ influx persisted in the combined presence of omega-agatoxin IVA (100 nM) and nitrendipine (1 microM). Simultaneous exposure to omega-agatoxin IVA and PMA inhibited both the early [Ca2+]i transients and Mn2+ quenching to a much greater extent than each drug separately. Inhibition of the [Ca2+]i transients by nitrendipine and PMA did not significantly exceed that produced by PMA alone. It is concluded that phorbol ester-mediated activation of protein kinase C inhibits preferentially L-type VSCCs over P/Q type channels in adrenal chromaffin cells. However, the possibility cannot be ruled out that dihydropyridine-resistant, non-P/Q type channels might also be negatively regulated by protein kinase C. This may represent an important pathway for the specific control of VSCCs by protein kinase C

  6. Beam halo in high-intensity beams

    International Nuclear Information System (INIS)

    Wangler, T.P.

    1993-01-01

    In space-charge dominated beams the nonlinear space-charge forces produce a filamentation pattern, which in projection to the 2-D phase spaces results in a 2-component beam consisting of an inner core and a diffuse outer halo. The beam-halo is of concern for a next generation of cw, high-power proton linacs that could be applied to intense neutron generators for nuclear materials processing. The author describes what has been learned about beam halo and the evolution of space-charge dominated beams using numerical simulations of initial laminar beams in uniform linear focusing channels. Initial results are presented from a study of beam entropy for an intense space-charge dominated beam

  7. A high-intensity plasma-sputter heavy negative ion source

    International Nuclear Information System (INIS)

    Alton, G.D.; Mori, Y.; Takagi, A.; Ueno, A.; Fukumoto, S.

    1989-01-01

    A multicusp magnetic field plasma surface ion source, normally used for H/sup /minus//ion beam formation, has been modified for the generation of high-intensity, pulsed, heavy negative ion beams suitable for a variety of uses. To date, the source has been utilized to produce mA intensity pulsed beams of more than 24 species. A brief description of the source, and basic pulsed-mode operational data, (e.g., intensity versus cesium oven temperature, sputter probe voltage, and discharge pressure), are given. In addition, illustrative examples of intensity versus time and the mass distributions of ion beams extracted from a number of samples along with emittance data, are also presented. Preliminary results obtained during dc operation of the source under low discharge power conditions suggest that sources of this type may also be used to produce high-intensity (mA) dc beams. The results of these investigations are given, as well, and the technical issues that must be addressed for this mode of operation are discussed. 15 refs., 10 figs., 2 tabs

  8. X-ray absorption intensity at high-energy region

    International Nuclear Information System (INIS)

    Fujikawa, Takashi; Kaneko, Katsumi

    2012-01-01

    We theoretically discuss X-ray absorption intensity in high-energy region far from the deepest core threshold to explain the morphology-dependent mass attenuation coefficient of some carbon systems, carbon nanotubes (CNTs), highly oriented pyrolytic graphite (HOPG) and fullerenes (C 60 ). The present theoretical approach is based on the many-body X-ray absorption theory including the intrinsic losses (shake-up losses). In the high-energy region the absorption coefficient has correction term dependent on the solid state effects given in terms of the polarization part of the screened Coulomb interaction W p . We also discuss the tail of the valence band X-ray absorption intensity. In the carbon systems C 2s contribution has some influence on the attenuation coefficient even in the high energy region at 20 keV.

  9. Enhancing gas-phase reaction in a plasma using high intensity and high power ultrasonic acoustic waves

    DEFF Research Database (Denmark)

    2010-01-01

    is absorbed into said plasma (104), and where a sound pressure level of said generated ultrasonic high intensity and high power acoustic waves (102) is at least substantially 140 dB and where an acoustic power of said generated ultrasonic high intensity and high power acoustic waves (102); is at least...... substantially 100 W. In this way, a high sound intensity and power are obtained that efficiently enhances a gas-phase reaction in the plasma, which enhances the plasma process, e.g. enabling more efficient ozone or hydrogen generation using plasma in relation to reaction speed and/or obtained concentration......This invention relates to enhancing a gas-phase reaction in a plasma comprising: creating plasma (104) by at least one plasma source (106), and wherein that the method further comprises: generating ultrasonic high intensity and high power acoustic waves (102) having a predetermined amount...

  10. Low-volume high-intensity swim training is superior to high-volume low-intensity training in relation to insulin sensitivity and glucose control in inactive middle-aged women.

    Science.gov (United States)

    Connolly, Luke J; Nordsborg, Nikolai B; Nyberg, Michael; Weihe, Pál; Krustrup, Peter; Mohr, Magni

    2016-10-01

    We tested the hypothesis that low-volume high-intensity swimming has a larger impact on insulin sensitivity and glucose control than high-volume low-intensity swimming in inactive premenopausal women with mild hypertension. Sixty-two untrained premenopausal women were randomised to an inactive control (n = 20; CON), a high-intensity low-volume (n = 21; HIT) or a low-intensity high-volume (n = 21; LIT) training group. During the 15-week intervention period, HIT performed 3 weekly 6-10 × 30-s all-out swimming intervals (average heart rate (HR) = 86 ± 3 % HRmax) interspersed by 2-min recovery periods and LIT swam continuously for 1 h at low intensity (average HR = 73 ± 3 % HRmax). Fasting blood samples were taken and an oral glucose tolerance test (OGTT) was conducted pre- and post-intervention. After HIT, resting plasma [insulin] was lowered (17 ± 34 %; P high-intensity intermittent swimming is an effective and time-efficient training strategy for improving insulin sensitivity, glucose control and biomarkers of vascular function in inactive, middle-aged mildly hypertensive women.

  11. Development of a high intensity proton accelerator

    International Nuclear Information System (INIS)

    Mizumoto, Motoharu; Kusano, Joichi; Hasegawa, Kazuo; Ito, Nobuo; Oguri, Hidetomo; Touchi, Yutaka; Mukugi, Ken; Ino, Hiroshi

    1997-01-01

    The high-intensity proton linear accelerator with a beam power of 15 MW has been proposed for various engineering tests for the nuclear waste transmutation system as one of the research plans in the Neutron Science Research Program (NSRP) in JAERI. High intensity proton beam and secondary particle beams such as neutron, pion, muon and unstable radio isotope (RI) beam generated from the proton spallation reaction will be utilized at these facilities in each research field. The R and D work has been carried out for the components of the front-end part of the proton accelerator; ion source, RFQ, DTL and RF source. In the beam test, the current of 70 mA with a duty factor of 7% has been accelerated from the RFQ at the energy of 2 MeV. A hot test model of the DTL for the high power and high duty operation was fabricated and tested. For the high energy portion above 100 MeV, superconducting accelerating cavity is studied as a main option. The superconducting linac is expected to have several favourable characteristics for high intensity accelerator such as short accelerator length, large bore radius resulting in low beam losses and cost effectiveness for construction and operation. A test stand with equipment of cryogenics system, vacuum system, RF system and cavity processing and cleaning is prepared to test the physics issues and fabrication process. The proposed plan for accelerator design and construction will compose of two consecutive stages. The first stage will be completed in about 7 years with the beam power of 1.5 MW. As the second stage gradual upgrading of the beam power will be made up to 15 MW. 7 refs., 3 figs., 4 tabs

  12. Consistency of neutron and proton capture intensity standards new relative intensities for 56Co, 66Ga decay and 35Cl(n,γ) reaction gamma rays

    International Nuclear Information System (INIS)

    Molnar, G.L.; Revay, Z.; Belgya, T.

    2000-01-01

    The equivalence of efficiency determination procedures based on neutron and proton capture lines has been verified and the deviation of high-energy efficiency from linearity confirmed. The new, accurate relative intensities for 56 Co and 66 Ga extend the range of secondary radioactive standards up to 4.8 MeV. Extreme care has to be taken with any high-energy intensity value obtained in the past with the help of 56 Co and 66 Ga calibration sources, and corrections have to be made using the present data of high accuracy. Relative intensities have also been improved for the 35 Cl(n,γ) reaction, a useful secondary standard in a wide energy range, between 0.3-8.5 MeV. The new data are supported by other most recent measurements of a slightly lower precision

  13. High-intensity interval training versus moderate-intensity continuous training within cardiac rehabilitation: a systematic review and meta-analysis.

    Science.gov (United States)

    Hannan, Amanda L; Hing, Wayne; Simas, Vini; Climstein, Mike; Coombes, Jeff S; Jayasinghe, Rohan; Byrnes, Joshua; Furness, James

    2018-01-01

    Aerobic capacity has been shown to be inversely proportionate to cardiovascular mortality and morbidity and there is growing evidence that high-intensity interval training (HIIT) appears to be more effective than moderate-intensity continuous training (MICT) in improving cardiorespiratory fitness within the cardiac population. Previously published systematic reviews in cardiovascular disease have neither investigated the effect that the number of weeks of intervention has on cardiorespiratory fitness changes, nor have adverse events been collated. We aimed to undertake a systematic review and meta-analysis of randomized controlled trials (RCTs) within the cardiac population that investigated cardiorespiratory fitness changes resulting from HIIT versus MICT and to collate adverse events. A critical narrative synthesis and meta-analysis was conducted after systematically searching relevant databases up to July 2017. We searched for RCTs that compared cardiorespiratory fitness changes resulting from HIIT versus MICT interventions within the cardiac population. Seventeen studies, involving 953 participants (465 for HIIT and 488 for MICT) were included in the analysis. HIIT was significantly superior to MICT in improving cardiorespiratory fitness overall (SMD 0.34 mL/kg/min; 95% confidence interval [CI; 0.2-0.48]; p HIIT intervention (n=9). However, some adverse events (n=5) were not classified by intervention group. HIIT is superior to MICT in improving cardiorespiratory fitness in participants of cardiac rehabilitation (CR). Improvements in cardiorespiratory fitness are significant for CR programs of >6-week duration. Programs of 7-12 weeks' duration resulted in the largest improvements in cardiorespiratory fitness for patients with coronary artery disease. HIIT appears to be as safe as MICT for CR participants.

  14. High-intensity interval training versus moderate-intensity continuous training within cardiac rehabilitation: a systematic review and meta-analysis

    Science.gov (United States)

    Hannan, Amanda L; Hing, Wayne; Simas, Vini; Climstein, Mike; Coombes, Jeff S; Jayasinghe, Rohan; Byrnes, Joshua; Furness, James

    2018-01-01

    Background Aerobic capacity has been shown to be inversely proportionate to cardiovascular mortality and morbidity and there is growing evidence that high-intensity interval training (HIIT) appears to be more effective than moderate-intensity continuous training (MICT) in improving cardiorespiratory fitness within the cardiac population. Previously published systematic reviews in cardiovascular disease have neither investigated the effect that the number of weeks of intervention has on cardiorespiratory fitness changes, nor have adverse events been collated. Objective We aimed to undertake a systematic review and meta-analysis of randomized controlled trials (RCTs) within the cardiac population that investigated cardiorespiratory fitness changes resulting from HIIT versus MICT and to collate adverse events. Methods A critical narrative synthesis and meta-analysis was conducted after systematically searching relevant databases up to July 2017. We searched for RCTs that compared cardiorespiratory fitness changes resulting from HIIT versus MICT interventions within the cardiac population. Results Seventeen studies, involving 953 participants (465 for HIIT and 488 for MICT) were included in the analysis. HIIT was significantly superior to MICT in improving cardiorespiratory fitness overall (SMD 0.34 mL/kg/min; 95% confidence interval [CI; 0.2–0.48]; pHIIT intervention (n=9). However, some adverse events (n=5) were not classified by intervention group. Conclusion HIIT is superior to MICT in improving cardiorespiratory fitness in participants of cardiac rehabilitation (CR). Improvements in cardiorespiratory fitness are significant for CR programs of >6-week duration. Programs of 7–12 weeks’ duration resulted in the largest improvements in cardiorespiratory fitness for patients with coronary artery disease. HIIT appears to be as safe as MICT for CR participants. PMID:29416382

  15. Molecular characterisation of a calmodulin gene, VcCaM1, that is differentially expressed under aluminium stress in highbush blueberry.

    Science.gov (United States)

    Inostroza-Blancheteau, C; Aquea, F; Loyola, R; Slovin, J; Josway, S; Rengel, Z; Reyes-Díaz, M; Alberdi, M; Arce-Johnson, P

    2013-11-01

    Calmodulin (CaM), a small acidic protein, is one of the best characterised Ca(2+) sensors in eukaryotes. This Ca(2+) -regulated protein plays a critical role in decoding and transducing environmental stress signals by activating specific targets. Many environmental stresses elicit changes in intracellular Ca(2+) activity that could initiate adaptive responses under adverse conditions. We report the first molecular cloning and characterisation of a calmodulin gene, VcCaM1 (Vaccinium corymbosum Calmodulin 1), in the woody shrub, highbush blueberry. VcCaM1 was first identified as VCAL19, a gene induced by aluminium stress in V. corymbosum L. A full-length cDNA of VcCaM1 containing a 766-bp open reading frame (ORF) encoding 149 amino acids was cloned from root RNA. The sequence encodes four Ca(2+) -binding motifs (EF-hands) and shows high similarity (99%) with the isoform CaM 201 of Daucus carota. Expression analyses showed that following Al treatment, VcCaM1 message level decreased in roots of Brigitta, an Al-resistant cultivar, and after 48 h, was lower than in Bluegold, an Al-sensitive cultivar. VcCAM1 message also decreased in leaves of both cultivars within 2 h of treatment. Message levels in leaves then increased by 24 h to control levels in Brigitta, but not in Bluegold, but then decreased again by 48 h. In conclusion, VcCaM1 does not appear to be directly involved in Al resistance, but may be involved in improved plant performance under Al toxicity conditions through regulation of Ca(2+) homeostasis and antioxidant systems in leaves. © 2013 German Botanical Society and The Royal Botanical Society of the Netherlands.

  16. Enhancing Plasma Surface Modification using high Intensity and high Power Ultrasonic Acoustic Waves

    DEFF Research Database (Denmark)

    2010-01-01

    high intensity and high power acoustic waves (102) by at least one ultrasonic high intensity and high power acoustic wave generator (101 ), wherein the ultrasonic acoustic waves are directed to propagate towards said surface (314) of the object (100) so that a laminar boundary layer (313) of a gas...... or a mixture of gases (500) flow in contact with said solid object (100) is thinned or destructed for at least a part of said surface (314). In this way, the plasma can more efficiently access and influence the surface of the solid object to be treated by the plasma, which speeds the process time up...

  17. Cellular Response to Doping of High Porosity Foamed Alumina with Ca, P, Mg, and Si

    Directory of Open Access Journals (Sweden)

    Edwin Soh

    2015-03-01

    Full Text Available Foamed alumina was previously synthesised by direct foaming of sulphate salt blends varying ammonium mole fraction (AMF, foaming heating rate and sintering temperature. The optimal product was produced with 0.33AMF, foaming at 100 °C/h and sintering at 1600 °C. This product attained high porosity of 94.39%, large average pore size of 300 µm and the highest compressive strength of 384 kPa. To improve bioactivity, doping of porous alumina by soaking in dilute or saturated solutions of Ca, P, Mg, CaP or CaP + Mg was done. Saturated solutions of Ca, P, Mg, CaP and CaP + Mg were made with excess salt in distilled water and decanted. Dilute solutions were made by diluting the 100% solution to 10% concentration. Doping with Si was done using the sol gel method at 100% concentration only. Cell culture was carried out with MG63 osteosarcoma cells. Cellular response to the Si and P doped samples was positive with high cell populations and cell layer formation. The impact of doping with phosphate produced a result not previously reported. The cellular response showed that both Si and P doping improved the biocompatibility of the foamed alumina.

  18. Elevated serum CA 19-9 at screening tests: underlying conditions and role of abdominopelvic CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Yang [University of Louisville, Department of Radiology and Molecular Imaging Research Center, Louisville, KY (United States); Seoul National University Hospital, Department of Radiology, Healthcare System Gangnam Center, Seoul (Korea, Republic of); Kim, Se Hyung [Seoul National University Hospital, Department of Radiology and the Institute of Radiation Medicine, Seoul (Korea, Republic of); Kim, Soo Young [Seoul National University Hospital, Department of Radiology, Healthcare System Gangnam Center, Seoul (Korea, Republic of); Bundang CHA Hospital, Department of Radiology, Bundang (Korea, Republic of)

    2014-10-15

    To investigate underlying conditions of patients with elevated CA 19-9 at screening tests and to evaluate diagnostic performance of abdominopelvic CT. One hundred and thirteen patients with elevated CA 19-9 (>37 U/ml) who underwent abdominopelvic CT in a screening program were selected. Underlying conditions were determined by reviewing all available data and follow-up records. Patients were categorized into malignancy, benign, and normal/non-related disease groups. Their mean CA 19-9 and percent of patients with CA 19-9 ≥ 100 U/ml were compared. Diagnostic sensitivity of CT for detecting underlying conditions of elevated CA 19-9 was analysed. Seventeen patients (17/113, 15 %) had 17 elevated CA 19-9-related malignancies, and 55 patients (55/113, 48.7 %) had 70 benign diseases. Mean CA 19-9 and percent of patients with CA 19-9 ≥ 100 U/ml in the malignancy group were significantly higher than in the two other groups. CT detected all except one malignant lesion with a detection sensitivity of 94.1 % (16/17). Of 70 CA 19-9-related benign diseases, CT detected 34 benign diseases (48.6 %) providing an alternative diagnosis for elevated CA 19-9. Abdominopelvic CT is not only useful in detecting malignancies, but can also diagnose alternative benign causes of elevated CA 19-9 in asymptomatic screening tests. (orig.)

  19. High-intensity, subkilovolt x-ray calibration facility

    International Nuclear Information System (INIS)

    Kuckuck, R.W.; Gaines, J.L.; Ernst, R.D.

    1976-01-01

    A high-intensity subkilovolt x-ray calibration source utilizing proton-induced inner-shell atomic fluorescence of low-Z elements is described. The high photon yields and low bremsstrahlung background associated with this phenomenon are ideally suited to provide intense, nearly monoenergetic x-ray beams. The proton accelerator is a 3 mA, 300 kV Cockroft-Walton using a conventional rf hydrogen ion source. Seven remotely-selectable targets capable of heat dissipation of 5 kW/cm 2 are used to provide characteristic x-rays with energies between 100 and 1000 eV. Source strengths are of the order of 10 13 to 10 14 photons/sec. Methods of reducing spectral contamination due to hydrocarbon build-up on the target are discussed. Typical x-ray spectra (Cu-L, C-K and B-K) are shown

  20. Hydrolysis of molten CaCl2-CaF2 with additions of CaO

    Directory of Open Access Journals (Sweden)

    Espen Olsen

    2017-10-01

    Full Text Available Calcium halide based molten salts have recently attracted interest for a number of applications such as direct reduction of oxides for metal production and as liquefying agent in cyclic sorption processes for CO2 by CaO from dilute flue gases (Ca-looping. A fundamental aspect of these melts is the possible hydrolysis reaction upon exposure to gaseous H2O forming corrosive and poisonous hydrogen halides. In this work experiments have been performed investigating the formation of HCl and HF from a molten salt consisting of a 13.8 wt% CaF2 in CaCl2 eutectic exposed to a flowing gas consisting of 10 vol% H2O in N2. Hydrolysis has been investigated as function of content of CaO and temperature. HCl and HF are shown to be formed at elevated temperatures; HCl forms to a substantially larger extent than HF. Addition of CaO has a marked, limiting effect on the hydrolysis. Thermodynamic modeling of the reaction indicates activity coefficients for CaO above unity in the system. For cyclic CO2-capture based on thermal swing, it is advisable to keep the temperature in the carbonation (absorption reactor well below 850 ℃ while maintaining a high CaO content if molten CaCl2 is employed. Similar conclusions can be drawn with regards to CaF2.

  1. ARRONAX, a high-energy and high-intensity cyclotron for nuclear medicine

    International Nuclear Information System (INIS)

    Haddad, Ferid; Guertin, Arnaud; Michel, Nathalie; Ferrer, Ludovic; Carlier, Thomas; Barbet, Jacques; Chatal, Jean-Francois

    2008-01-01

    This study was aimed at establishing a list of radionuclides of interest for nuclear medicine that can be produced in a high-intensity and high-energy cyclotron. We have considered both therapeutic and positron emission tomography radionuclides that can be produced using a high-energy and a high-intensity cyclotron such as ARRONAX, which will be operating in Nantes (France) by the end of 2008. Novel radionuclides or radionuclides of current limited availability have been selected according to the following criteria: emission of positrons, low-energy beta or alpha particles, stable or short half-life daughters, half-life between 3 h and 10 days or generator-produced, favourable dosimetry, production from stable isotopes with reasonable cross sections. Three radionuclides appear well suited to targeted radionuclide therapy using beta ( 67 Cu, 47 Sc) or alpha ( 211 At) particles. Positron emitters allowing dosimetry studies prior to radionuclide therapy ( 64 Cu, 124 I, 44 Sc), or that can be generator-produced ( 82 Rb, 68 Ga) or providing the opportunity of a new imaging modality ( 44 Sc) are considered to have a great interest at short term whereas 86 Y, 52 Fe, 55 Co, 76 Br or 89 Zr are considered to have a potential interest at middle term. Several radionuclides not currently used in routine nuclear medicine or not available in sufficient amount for clinical research have been selected for future production. High-energy, high-intensity cyclotrons are necessary to produce some of the selected radionuclides and make possible future clinical developments in nuclear medicine. Associated with appropriate carriers, these radionuclides will respond to a maximum of unmet clinical needs. (orig.) 5

  2. Application of the Speed-Duration Relationship to Normalize the Intensity of High-Intensity Interval Training

    Science.gov (United States)

    Ferguson, Carrie; Wilson, John; Birch, Karen M.; Kemi, Ole J.

    2013-01-01

    The tolerable duration of continuous high-intensity exercise is determined by the hyperbolic Speed-tolerable duration (S-tLIM) relationship. However, application of the S-tLIM relationship to normalize the intensity of High-Intensity Interval Training (HIIT) has yet to be considered, with this the aim of present study. Subjects completed a ramp-incremental test, and series of 4 constant-speed tests to determine the S-tLIM relationship. A sub-group of subjects (n = 8) then repeated 4 min bouts of exercise at the speeds predicted to induce intolerance at 4 min (WR4), 6 min (WR6) and 8 min (WR8), interspersed with bouts of 4 min recovery, to the point of exercise intolerance (fixed WR HIIT) on different days, with the aim of establishing the work rate that could be sustained for 960 s (i.e. 4×4 min). A sub-group of subjects (n = 6) also completed 4 bouts of exercise interspersed with 4 min recovery, with each bout continued to the point of exercise intolerance (maximal HIIT) to determine the appropriate protocol for maximizing the amount of high-intensity work that can be completed during 4×4 min HIIT. For fixed WR HIIT tLIM of HIIT sessions was 399±81 s for WR4, 892±181 s for WR6 and 1517±346 s for WR8, with total exercise durations all significantly different from each other (PHIIT, there was no difference in tLIM of each of the 4 bouts (Bout 1: 229±27 s; Bout 2: 262±37 s; Bout 3: 235±49 s; Bout 4: 235±53 s; P>0.050). However, there was significantly less high-intensity work completed during bouts 2 (153.5±40. 9 m), 3 (136.9±38.9 m), and 4 (136.7±39.3 m), compared with bout 1 (264.9±58.7 m; P>0.050). These data establish that WR6 provides the appropriate work rate to normalize the intensity of HIIT between subjects. Maximal HIIT provides a protocol which allows the relative contribution of the work rate profile to physiological adaptations to be considered during alternative intensity-matched HIIT protocols. PMID:24244266

  3. Proteomic Profiling of Hematopoietic Stem/Progenitor Cells after a Whole Body Exposure of CBA/CaJ Mice to Titanium (48Ti Ions

    Directory of Open Access Journals (Sweden)

    Kanokporn Noy Rithidech

    2015-07-01

    Full Text Available Myeloid leukemia (ML is one of the major health concerns from exposure to radiation. However, the risk assessment for developing ML after exposure to space radiation remains uncertain. To reduce the uncertainty in risk prediction for ML, a much increased understanding of space radiation-induced changes in the target cells, i.e., hematopoietic stem/progenitor cells (HSPCs, is critically important. We used the label-free quantitative mass spectrometry (LFQMS proteomic approach to determine the expression of protein in HSPC-derived myeloid colonies obtained at an early time-point (one week and a late time-point (six months after an acute whole body exposure of CBA/CaJ mice to a total dose of 0, 0.1, 0.25, or 0.5 Gy of heavy-ion titanium (48Ti ions, which are the important component of radiation found in the space environment. Mice exposed to 0 Gy of 48Ti ions served as non-irradiated sham controls. There were five mice per treatment groups at each harvest time. The Trans-Proteomic Pipeline (TPP was used to assign a probability of a particular protein being in the sample. A proof-of-concept based Ingenuity Pathway Analysis (IPA was used to characterize the functions, pathways, and networks of the identified proteins. Alterations of expression levels of proteins detected in samples collected at one week (wk post-irradiation reflects acute effects of exposure to 48Ti ions, while those detected in samples collected at six months (mos post-irradiation represent protein expression profiles involved in the induction of late-occurring damage (normally referred to as genomic instability. Our results obtained by using the IPA analyses indicate a wide array of signaling pathways involved in response to 1 GeV/n 48Ti ions at both harvest times. Our data also demonstrate that the patterns of protein expression profiles are dose and time dependent. The majority of proteins with altered expression levels are involved in cell cycle control, cellular growth and

  4. CA V is present in rat kidney mitochondria

    International Nuclear Information System (INIS)

    Dodgson, S.J.; Contino, L.C.

    1987-01-01

    Guinea pig liver mitochondria contain the unique carbonic anhydrase isozyme, CA V. Prior to sacrifice, 15 rats and 15 guinea pigs were either fed normal lab chow (group 1), starved 48 hours (group 2) or fed normal lab chow and given to drink only water with added HCl, pH 2.5 (group 3). Mitochondria were prepared from excised livers and kidneys. CA V activity of disrupted mitochondria was measured by 18 O-mass spectrometric technique at pH 7.4, 37 0 C, 25 mM NaHCO 3 . Mass spectrometric CA assays with intact kidney mitochondria localize CA V activity to the matrix, as was found for liver mitochondria. It has been shown in hepatocytes prepared from starved guinea pigs and rats that inhibition of CA V results in decreased rate of gluconeogenesis from pyruvate. These present results are in line with the published observation that rat kidneys are much more gluconeogenic than guinea pig, and that this is increased by starvation and acidosis

  5. High Intensity Interval Training for Maximizing Health Outcomes.

    Science.gov (United States)

    Karlsen, Trine; Aamot, Inger-Lise; Haykowsky, Mark; Rognmo, Øivind

    Regular physical activity and exercise training are important actions to improve cardiorespiratory fitness and maintain health throughout life. There is solid evidence that exercise is an effective preventative strategy against at least 25 medical conditions, including cardiovascular disease, stroke, hypertension, colon and breast cancer, and type 2 diabetes. Traditionally, endurance exercise training (ET) to improve health related outcomes has consisted of low- to moderate ET intensity. However, a growing body of evidence suggests that higher exercise intensities may be superior to moderate intensity for maximizing health outcomes. The primary objective of this review is to discuss how aerobic high-intensity interval training (HIIT) as compared to moderate continuous training may maximize outcomes, and to provide practical advices for successful clinical and home-based HIIT. Copyright © 2017. Published by Elsevier Inc.

  6. A comparative study on Ca content and distribution in two Gesneriaceae species reveals distinctive mechanisms to cope with high rhizospheric soluble calcium

    Directory of Open Access Journals (Sweden)

    Wenlong eLi

    2014-11-01

    Full Text Available Excessive Ca is toxic to plants thus significantly affects plant growth and species distribution in Ca-rich karst areas. To understand how plants survive high Ca soil, laboratory experiments were established to compare the physiological responses and internal Ca distribution in organ, tissue, cell and intracellular levels under different Ca levels for Lysionotus pauciflorus and Boea hygrometrica, two karst habitant Gesneriaceae species in Southwest China. In the controlled condition, L. pauciflorus could survive as high as 200 mM rhizospheric soluble Ca, attributed to a series of physiological responses and preferential storage that limited Ca accumulation in chloroplasts of palisade cells. In contrast, B. hygrometrica could survive only 20 mM rhizospheric soluble Ca, but accumulated a high level of internal Ca in both palisade and spongy cells without disturbance on photosynthetic activity. By phenotype screening of transgenic plants expressing high Ca-inducible genes from B. hygrometrica, the expression of BhDNAJC2 in A. thaliana was found to enhance plant growth and photosynthesis under high soluble Ca stress. BhDNAJC2 encodes a recently reported heat shock protein (HSP 40 family DnaJ-domain protein. The Ca-resistant phenotype of BhDNAJC2 highlights the important role of chaperone-mediated protein quality control in Ca tolerance in B. hygrometrica. Taken together, our results revealed that distinctive mechanisms were employed in the two Gesneriaceae karst habitants to cope with a high Ca environment.

  7. Luminescence of (Ca,Sr)3(VO4)2: Pr3+, Eu3+ phosphor for use in CuPc-based solar cells and white light-emitting diodes

    International Nuclear Information System (INIS)

    Lin, Han-Yu; Chang, Wei-Fu; Chu, Sheng-Yuan

    2013-01-01

    The purpose of this study is to enhance the red emission intensity and expand the blue excitation band of a (Ca,Sr) 2.82 (VO 4 ) 2 :0.12Eu 3+ phosphor for use in copper phthalocyanine (CuPc)-based solar cells and white light-emitting diodes. It was found that substitution of 3% Sr 2+ replacing Ca 2+ enhanced red emission intensity of Ca 2.82 (VO 4 ) 2 :0.12Eu 3+ by 14% under 465-nm by excitation. The Pr 3+ co-doping effect was realized when blue excitation intensity of (Ca 0.97 Sr 0.03 ) 2.82 (VO 4 ) 2 :0.12Eu 3+ , located in the weakest absorption of CuPc, was improved by 126% with the addition of 0.6 mol% Pr 3+ . The absorption spectrum of CuPc/optimized (Ca 0.9668 Sr 0.03 ) 2.82 (VO 4 ) 2 :0.006Pr 3+ , 0.12Eu 3+ mixtures provided evidence that the (Ca 0.9668 Sr 0.03 ) 2.82 (VO 4 ) 2 :0.006Pr 3+ , 0.12Eu 3+ phosphor could increase the efficiency of incident photons on CuPc-based solar cells. Moreover, the good temperature stability of emission intensity and chromaticity of (Ca 0.9668 Sr 0.03 ) 2.82 (VO 4 ) 2 :0.006Pr 3+ , 0.12Eu 3+ indicated a potential for this phosphor to be applied on the white light-emitting diodes. - Highlights: ► Substitution of 3% Sr 2+ replacing Ca 2+ enhanced red emission intensity of Ca 2.82 (VO 4 ) 2 :0.12Eu 3+ by 14% under 465 nm by excitation. ► Addition of 0.6 mol% Pr 3+ enhanced blue excitation intensity of (Ca 0.97 Sr 0.03 ) 2.82 (VO 4 ) 2 :0.12Eu 3+ , located in the weakest absorption of CuPc, by 126%. ► According to absorption measurements of CuPc/optimized (Ca 0.9668 Sr 0.03 ) 2.82 (VO 4 ) 2 :0.006Pr 3+ , 0.12Eu 3+ mixtures for the first time, the feasibility of our phosphor to assist CuPc in converting blue-wavelength photons was proved. ► High temperature stability of emission intensity and chromaticity of (Ca 0.9668 Sr 0.03 ) 2.82 (VO 4 ) 2 :0.006Pr 3+ , 0.12Eu 3+ indicated our phosphor is acceptable for WLED applications.

  8. The high intensity solar cell: Key to low cost photovoltaic power

    Science.gov (United States)

    Sater, B. L.; Goradia, C.

    1975-01-01

    The design considerations and performance characteristics of the 'high intensity' (HI) solar cell are presented. A high intensity solar system was analyzed to determine its cost effectiveness and to assess the benefits of further improving HI cell efficiency. It is shown that residential sized systems can be produced at less than $1000/kW peak electric power. Due to their superior high intensity performance characteristics compared to the conventional and VMJ cells, HI cells and light concentrators may be the key to low cost photovoltaic power.

  9. Synthesis, characterization and photoluminescence properties of Bi³⁺ co-doped CaSiO₃:Eu³⁺ nanophosphor.

    Science.gov (United States)

    Kumar, M Madesh; Krishna, R Hari; Nagabhushana, B M; Shivakumara, C

    2015-03-15

    Ceramic luminescent powders with the composition Ca(0.96-x)Eu0.04Bi(x)SiO3 (x=0.01-0.05) were prepared by solution combustion method. The nanopowders are characterized by powder X-ray diffraction (PXRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FTIR) and photoluminescence (PL) techniques. PXRD patterns of calcined (950°C for 3h) Ca(0.96-x)Eu0.04Bi(x)SiO3 powders exhibit monoclinic phase with mean crystallite sizes ranging from 28 to 48 nm. SEM micrographs show the products are foamy, agglomerated and fluffy in nature due to the large amount of gases liberated during combustion reaction. TEM micrograph shows the crystalline characteristics of the nanoparticles. Upon 280 nm excitation, the photoluminescence of the Ca(0.96-x)Eu0.04Bi(x)SiO3 particles show red emission at 611 nm corresponding to 5D0→7F2 transition. It is observed that PL intensity increases with Bi(3+) concentration. Our work demonstrates very interesting energy transfer from Bi(3+) to Eu(3+) in CaSiO3 host. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Purification of charybdotoxine, a specific inhibitor of the high-conductance Ca2+-activated K+ channel

    International Nuclear Information System (INIS)

    Smith, C.; Phillips, M.; Miller, C.

    1986-01-01

    Charybdotoxim is a high-affinity specific inhibitor of the high-conductance Ca 2+ -activated K + channel found in the plasma membranes of many vertebrate cell types. Using Ca 2+ -activated K + channels reconstituted into planar lipid bilayer membranes as an assay, the authors have purified the toxin from the venom of the scorpion Leiurus quinquestriatus by a two-step procedure involving chromatofocusing on SP-Sephadex, followed by reversed-phase high-performance liquid chromatography. Charybdotoxin is shown to be a highly basic protein with a mass of 10 kDa. Under the standard assay conditions, the purified toxin inhibits the Ca 2+ -activated K + channel with an apparent dissociation constant of 3.5 nM. The protein is unusually stable, with inhibitory potency being insensitive to boiling or exposure to organic solvents. The toxin's activity is sensitive to chymotrypsin treatment and to acylation of lysine groups. The protein may be radioiodinated without loss of activity

  11. New limits on 2β processes in 40Ca and 46Ca by using low radioactive CaF2(Eu) crystal scintillators

    International Nuclear Information System (INIS)

    Belli, P.; Bernabei, R.; Dai, C.J.

    2001-01-01

    The development of highly radiopure CaF 2 (Eu) crystal scintillators has been performed aiming at a substantial sensitivity enhancement of the 2β decay investigation and of the search for dark matter particles with spin-dependent (SD) interaction. The results of CaF 2 (Eu) background measurements and simulation are presented. New and highly improved T 1/2 limits on the 2β decay of 46 Ca and the double electron capture of 40 Ca are obtained

  12. A transparent vacuum window for high-intensity pulsed beams

    CERN Document Server

    Monteil, M; Veness, R

    2011-01-01

    The HiRadMat (High-Radiation to Materials) facility Ill will allow testing of accelerator components, in particular those of the Large Hadron Collider (LHC) at CERN, under the impact of high-intensity pulsed beams. To reach this intensity range, the beam will be focused on a focal point where the target to be tested is located. A 60 mm aperture vacuum window will separate the vacuum of the beam line which is kept under high vacuum 10(-8) mbar, from the test area which is at atmospheric pressure. This window has to resist collapse due to beam passage. The high-intensity of the beam means that typical materials used for standard vacuum windows (such as stainless steel, aluminium and titanium alloy) cannot endure the energy deposition induced by the beam passage. Therefore, a vacuum window has been designed to maintain the differential pressure whilst resisting collapse due to the beam impact on the window. In this paper, we will present calculations of the energy transfer from beam to window, the design of the ...

  13. Ion source and injection line for high intensity medical cyclotron

    Science.gov (United States)

    Jia, XianLu; Guan, Fengping; Yao, Hongjuan; Zhang, TianJue; Yang, Jianjun; Song, Guofang; Ge, Tao; Qin, Jiuchang

    2014-02-01

    A 14 MeV high intensity compact cyclotron, CYCIAE-14, was built at China Institute of Atomic Energy (CIAE). An injection system based on the external H- ion source was used on CYCIAE-14 so as to provide high intensity beam, while most positron emission tomography cyclotrons adopt internal ion source. A beam intensity of 100 μA/14 MeV was extracted from the cyclotron with a small multi-cusp H- ion source (CIAE-CH-I type) and a short injection line, which the H- ion source of 3 mA/25 keV H- beam with emittance of 0.3π mm mrad and the injection line of with only 1.2 m from the extraction of ion source to the medial plane of the cyclotron. To increase the extracted beam intensity of the cyclotron, a new ion source (CIAE-CH-II type) of 9.1 mA was used, with maximum of 500 μA was achieved from the cyclotron. The design and test results of the ion source and injection line optimized for high intensity acceleration will be given in this paper.

  14. PIK3CA activating mutation in colorectal carcinoma: associations with molecular features and survival.

    Directory of Open Access Journals (Sweden)

    Christophe Rosty

    Full Text Available Mutations in PIK3CA are present in 10 to 15% of colorectal carcinomas. We aimed to examine how PIK3CA mutations relate to other molecular alterations in colorectal carcinoma, to pathologic phenotype and survival. PIK3CA mutation testing was carried out using direct sequencing on 757 incident tumors from the Melbourne Collaborative Cohort Study. The status of O-6-methylguanine-DNA methyltransferase (MGMT was assessed using both immunohistochemistry and methyLight techniques. Microsatellite instability, CpG island phenotype (CIMP, KRAS and BRAF V600E mutation status, and pathology review features were derived from previous reports. PIK3CA mutation was observed in 105 of 757 (14% of carcinomas, characterized by location in the proximal colon (54% vs. 34%; P<0.001 and an increased frequency of KRAS mutation (48% vs. 25%; P<0.001. High-levels of CIMP were more frequently found in PIK3CA-mutated tumors compared with PIK3CA wild-type tumors (22% vs. 11%; P = 0.004. There was no difference in the prevalence of BRAF V600E mutation between these two tumor groups. PIK3CA-mutated tumors were associated with loss of MGMT expression (35% vs. 20%; P = 0.001 and the presence of tumor mucinous differentiation (54% vs. 32%; P<0.001. In patients with wild-type BRAF tumors, PIK3CA mutation was associated with poor survival (HR 1.51 95% CI 1.04-2.19, P = 0.03. In summary, PIK3CA-mutated colorectal carcinomas are more likely to develop in the proximal colon, to demonstrate high levels of CIMP, KRAS mutation and loss of MGMT expression. PIK3CA mutation also contributes to significantly decreased survival for patients with wild-type BRAF tumors.

  15. Neutrophil gelatinase-associated lipocalin levels during the first 48 hours of intensive care may indicate upcoming acute kidney injury.

    Science.gov (United States)

    Kamis, Fatih; Yegenaga, Itir; Musul, Mert; Baydemir, Canan; Bek, Sibel; Kalender, Betül; Baykara, Nur

    2016-08-01

    The recognition of acute kidney injury (AKI) as early as possible is important in the intensive care unit. This study proposes that serum and urine levels of neutrophil gelatinase-associated lipocalin (NGAL) may be used for this purpose. One hundred and seven critically ill adult patients with no previous renal failure were included. NGAL levels were measured during the first 48 hours after admission; NGAL levels were followed for 7 days and classified based on Risk, Injury, Failure, Loss, and End-Stage Renal Failure criteria. The AKI incidence was 35.5%, and serum NGAL (sNGAL) and urinary NGAL (uNGAL) levels were higher in the AKI group. The area under the receiver operating characteristic curve was 0.76 (P<.001) for sNGAL and 0.75 (P<.001) for uNGAL. Seventy-one percent of AKI cases were observed within 48 hours, with 11 additional cases in the ensuing 7 days. The mean serum creatinine levels in the 11 patients were not different from non-AKI levels (P=.197), but the NGAL values were different, and the area under the receiver operating characteristic curve for sNGAL uNGAL was 1.00 (P=.014) and 0.93 (P=.02), respectively. Most AKI cases were diagnosed within the first 48 hours after admission, and NGAL was useful for predicting upcoming AKI. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Photoluminescence of electron beam evaporated CaS:Bi thin films

    CERN Document Server

    Smet, P F; Poelman, D R; Meirhaeghe, R L V

    2003-01-01

    For the first time, the photoluminescence (PL) of electron beam evaporated CaS:Bi thin films is reported. Luminescent CaS:Bi powder prepared out of aqueous solutions was used as source material. The influence of substrate temperature on the PL and the morphology of thin films is discussed, and an optimum is determined. Substrate temperatures between 200 deg. C and 300 deg. C lead to good quality thin films with sufficient PL intensity. As-deposited thin films show two emission bands, peaking at 450 and 530 nm. Upon annealing the emission intensity increases, and annealing at 800 deg. C is sufficient to obtain a homogeneously blue emitting thin film (CIE colour coordinates (0.17; 0.12)), thanks to a single remaining emission band at 450 nm. The influence of ambient temperature on the PL of CaS:Bi powder and thin films was also investigated and it was found that CaS:Bi thin films show a favourable thermal quenching behaviour near room temperature.

  17. EFFECT OF HIGH & LOW INTENSITIES OF AEROBIC EXERCISE ON PHYSICAL FITNESS INDEX

    Directory of Open Access Journals (Sweden)

    Madhusudhan

    2015-06-01

    Full Text Available BACKGROUND: Aerobic exercise reduces body fat and improves weight control, increases HDL&Vo2 max. Also improves PFI (physical fitness index which is defined as ability to carry out daily tasks with vigour and alertness without undue fatigue. Though aerobic exercise is found to improve physical fitness, the relative merits of different intensities of aerobi c exercise in improving physical fitness is still uncertain. AIM: The present study was conducted to know the Effect of High & low intensity aerobic training on physical fitness index. MATERIALS & METHODS : 80 sedentary men (18 - 40 years were randomized in to 2 equal groups (High Intensity & low intensity group . The High [80% HR max] & Low intensity [50 % HR max] groups underwent aerobic exercise training using Bicycle ergo meter (COSCO at 900kpm & 540kpm, for 15mins/day & 30mins/day respectively, 5days a week, for a period of 14weeks. Physical fitness index of each subject was recorded by Modified Harvard step test before & after intervention. RESULTS : After 14 weeks of aerobic training both the exercise groups had improvement in PFI, but high intensity gr oup had a significant (p<0.05 improvement in PFI (97.18 - 101.14 than low intensity group (98.12 - 100.6. CONCLUSION : High intensity aerobic exercise is effective in improving physical fitness.

  18. High signal intensity of fat on fast spin echo imaging

    International Nuclear Information System (INIS)

    Ogura, Akio; Yamazaki, Masaru; Hongoh, Takaharu; Inoue, Hiroshi; Ishikuro, Akihiro

    2000-01-01

    The fast spin echo (FSE) technique of producing T 2 -weighted images in greatly reduced imaging times has recently been used for routine clinical study. FSE images show contrast that is very similar in most tissues to that of conventional SE images. However, fat shows a high signal intensity that is influenced by j-coupling and the magnetization transfer effect. The purpose of this study was to assess whether the higher signal intensity of fat is different among MRI systems and to examine the effects of j-coupling and magnetization transfer on the high signal intensity of fat on FSE. The contrast in signal intensity between fat and water was measured for various echo train lengths (ETL) with and without multislicing on FSE using a contrast phantom. Measurements were obtained with four different MRI systems. In addition, the effective T 2 values of fat were calculated for the above conditions. Results indicated that contrast for fat and water was reduced with increased ETL and by using multislicing and was different among the four MRI systems. The effective T 2 values of fat were extended for increased ETL and were not dependent on multislicing. They also differed among the four MRI systems. The extent of effective T 2 values was affected by j-coupling. In this study, it was indicated that the degree of the high signal intensity of fat on FSE differed for different MRI systems. In addition, the reasons for the high signal intensity of fat on FSE were related to the effects of j-coupling and magnetization transfer. (author)

  19. Suppression of the increasing level of acetylcholine-stimulated intracellular Ca2+ in guinea pig airway smooth muscle cells by mabuterol.

    Science.gov (United States)

    Song, Xirui; Zhao, Chao; Dai, Cailing; Ren, Yanxin; An, Nan; Wen, Huimin; Pan, L I; Cheng, Maosheng; Zhang, Yuyang

    2015-11-01

    The present study aimed to establish an effective method for the in vitro culture of guinea pig airway smooth muscle (ASM) cells, and also investigate the suppressive effect of mabuterol hydrochloride (Mab) on the increased level of intracellular Ca 2+ in ASM cells induced with acetylcholine (Ach). Two different methods, i.e. with or without collagenase to pretreat tracheal tissues, were applied to the manufacture of ASM cells. Cell viability was determined with the 3-(4,5-dimethylthinazol-2-yl)-2,5-diphenyltetrazolium bromide assay. Immunocytochemistry and immunofluorescence were used for the identification of ASM cells. Different concentration levels (10 -3 , 10 -4 , 10 -5 , 10 -6 and 10 -7 mmol/l) of Mab were administered 5 min before Ach (10 -4 M) treatment, respectively. The Ca 2+ fluorescent probe, Fura-2/AM or Fluo-3/AM were applied to the inspection of Ca 2+ fluorescent intensity with Varioskan Flash, immunocytometry systems and an inverted system microscope, respectively. The results showed that the fresh method, in which isolated tracheal tissues were previously treated with collagenase for 20 min, was more advantageous for the preparation of guinea pig ASM cells compared to when the enzyme was not used. The time for the ASM cells to initially migrate out of the 'tissue blocks' and the culture having to be generated due to the thick cell density was significantly less. On identification with immunocytochemistry or immunofluorescent staining, >95% of the cells were ASM cells. Mab (10 -3 -10 -7 mmol/l) significantly suppressed the elevation of intracellular Ca 2+ induced by Ach in a concentration-dependent manner. The inhibitory rates of intracellular Ca 2+ by different concentrations of Mab, from low to high, were 14.93, 24.73, 40.06, 48.54 and 57.13%, respectively, when Varioskan Flash was used for determination. In conclusion, this novel method has a shorter harvesting period for ASM cells. Mab can suppress the increasing level of intracellular Ca 2

  20. Novel Approach for the Remediation of Radioactive Cesium Contaminated Soil with nano-Fe/Ca/CaO Dispersion Mixture in Dry Condition

    Directory of Open Access Journals (Sweden)

    Mallampati S. R.

    2013-04-01

    Full Text Available Present study, first time we developed a nano-Fe/Ca/CaO dispersion mixture based remediation and volume reduction method of real radioactive cesium contaminated soils. After soil samples treated with 10wt% of nano-Fe/Ca/CaO dispersion mixtures, emitting radiation intensity was reduced from 4.00 μSv/h to 0.95 μSv/h in non-magnetic fraction soils. While, after treatment, about 30wt% magnetic and 70wt% nonmagnetic fraction soils were separated, and it’s condensed radioactive cesium concentration was about 80% and 20%, respectively. By this way, cesium contaminated soil volume can be reduced. These preliminary results appear to be very promising and the simple mixing with the addition of nano-Fe/Ca/CaO may be considered potentially applicable for the remediation and separation of radioactive Cs contaminated soil in dry conditions.

  1. The study towards high intensity high charge state laser ion sources.

    Science.gov (United States)

    Zhao, H Y; Jin, Q Y; Sha, S; Zhang, J J; Li, Z M; Liu, W; Sun, L T; Zhang, X Z; Zhao, H W

    2014-02-01

    As one of the candidate ion sources for a planned project, the High Intensity heavy-ion Accelerator Facility, a laser ion source has been being intensively studied at the Institute of Modern Physics in the past two years. The charge state distributions of ions produced by irradiating a pulsed 3 J/8 ns Nd:YAG laser on solid targets of a wide range of elements (C, Al, Ti, Ni, Ag, Ta, and Pb) were measured with an electrostatic ion analyzer spectrometer, which indicates that highly charged ions could be generated from low-to-medium mass elements with the present laser system, while the charge state distributions for high mass elements were relatively low. The shot-to-shot stability of ion pulses was monitored with a Faraday cup for carbon target. The fluctuations within ±2.5% for the peak current and total charge and ±6% for pulse duration were demonstrated with the present setup of the laser ion source, the suppression of which is still possible.

  2. Luminescence Properties of CaF2 Nanostructure Activated by Different Elements

    Directory of Open Access Journals (Sweden)

    Numan Salah

    2015-01-01

    Full Text Available Nanostructures of calcium fluoride (CaF2 doped with Eu, Tb, Dy, Cu, and Ag were synthesized by the coprecipitation method and studied for their thermoluminescence (TL and photoluminescence (PL properties. The PL emission spectrum of pure CaF2 nanostructure has a broad band in the 370–550 nm range. Similar spectra were observed in case of doped samples, beside extra bands related to these impurities. The maximum PL intensity was observed in Eu doped sample. The TL results of Eu, Cu, Ag, and Tb doped samples show weak glow peaks below 125°C, whereas Dy doped one is found to be highly sensitive with a prominent peak at 165°C. This sample was further exposed to a wide range of gamma rays exposures from 137Cs source. The response curve is linear in the 100 Gy-10 kGy range. It is also observed that the particle size of CaF2 nanostructure was significantly reduced by increasing Dy concentration. These results showed that Dy is a proper activator in the host of CaF2 nanostructure, providing a highly sensitive dosimeter in a wide range of exposures and also plays a role as a controlling agent for particle size growth.

  3. Influence of mature men way of life on highly intensive physical activity

    Directory of Open Access Journals (Sweden)

    O.B. Pryshva

    2017-04-01

    Full Text Available Highly intensive physical activity is the most effective for men’s health protection. In modern life conditions its level is insufficient. It requires organism’s appropriate physical activity, which is determined by way of life. Especially important it is before trainings. Purpose: to study special aspects of different intensity’s physical activity; of eating special food and sleeping regime of mature men before their highly intensive physical trainings. Material: in experiment men (n=26, age - 35-53years, who practice healthy life style and independent physical activity of high intensity, participated. We used bio-register Basis B1. Every day we registered: Peak - physical activity of different intensity; duration and quality of sleep; relative weight of consumed food. Besides, we calculated body mass index and physical condition. The study was conducted during 30 days in winter period. The following results were compared: indicators before not planned physical activity and average-monthly indicators. Results: Before arbitrary physical functioning we found in men: confident weakening of average intensity (by 9-11% and low intensity (by 10% physical activity; confident increase of consumed food’s relative weight (by 6.82%, vegetarian food (by 10.64% and raw food (by 7.61%; confident reduction of animal origin food (by 8.7%. No changes were found in duration and quality of sleep before highly intensive physical functioning. Conclusions: specific features of mature men’s way of life before their not planned highly intensive physical functioning are as follows: reduction of general physical activity; increase of consumed food. These factors facilitate energy accumulation in organism for its realization in highly intensive physical functioning the next day.

  4. The reaction {sup 48}Ca+{sup 238}U {yields}{sup 286}112{sup *} studied at the GSI-SHIP

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, S. [Gesellschaft fuer Schwerionenforschung (GSI), D-64291 Darmstadt (Germany); Institut fuer Kernphysik, Johann Wolfgang Goethe-Universitaet, Frankfurt (Germany); Ackermann, D.; Burkhard, H.G.; Heinz, S.; Hessberger, F.P.; Khuyagbaatar, J.; Kindler, B.; Kojouharov, I.; Lommel, B.; Mann, R.; Muenzenberg, G.; Schoett, H.J.; Sulignano, B. [Gesellschaft fuer Schwerionenforschung (GSI), Darmstadt (Germany); Antalic, S.; Saro, S.; Streicher, B.; Venhart, M. [Comenius University, Department of Nuclear Physics and Biophysics, Bratislava (Slovakia); Comas, V.F.; Heredia, J.A. [InSTEC, Habana (Cuba); Dressler, R. [Paul Scherrer Institute, Villigen (Switzerland); Gan, Z. [Chinese Academy of Sciences, Institute of Modern Physics, Lanzhou (China); Kuusiniemi, P. [University of Oulu, CUPP (Finland); Leino, M.; Uusitalo, J. [University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Nishio, K. [Japan Atomic Energy Agency, Tokai, Ibaraki (Japan); Popeko, A.G.; Yeremin, A.V. [JINR, Flerov Laboratory of Nuclear Reactions, Dubna (Russian Federation)

    2007-06-15

    The fusion reaction of {sup 48}Ca projectiles with {sup 238}U target nuclei was studied at the velocity filter SHIP of GSI in Darmstadt. Two decay chains were measured, which fully confirm data that were previously assigned to the isotope {sup 283}112 in experiments at the Flerov Laboratory in Dubna. Two other events are consistent with a 50% spontaneous-fission (SF) branch of this isotope. The mean value obtained for the half-life of {sup 283}112 is (6.9{sup +6.9}{sub -2.3}) s, the {alpha} energy is (9.520{+-}0.015) MeV, and the total kinetic energy (TKE) of SF is (238{+-}14) MeV. The half-life of the {alpha} decay daughter nucleus {sup 279}Ds is (0.18{sup +0.32}{sub -0.07}) s, and the TKE of SF is (210 {sup +32}{sub -11}) MeV. The cross-section deduced from all four events is (0.72{sup +0.58}{sub -0.35}) pb, measured at an excitation energy of 34.6MeV of the compound nucleus {sup 286}112. (orig.)

  5. The utilization of high-intensity lasers

    International Nuclear Information System (INIS)

    Fabre, E.

    1988-01-01

    The 1988 progress report of the laboratory for the Utilization of High-Intensity Lasers (Polytechnic School, France), is presented. The research program is focused on the laser-plasma physics, on the generation of high pressures by means of laser shock heating, on the laser spectroscopy and on the laser implosions. Numerical simulation codes are developed. Concerning the atomic physics, the investigations on dense plasmas and the x-laser research developments are carried out. The research activities of the laboratory teams, the published papers, the national and international cooperations, are given [fr

  6. Exploring reaction mechanisms and their competition in 58Ni+48Ca collisions at E = 25 AMeV

    Directory of Open Access Journals (Sweden)

    Francalanza L.

    2014-03-01

    Full Text Available Latest results concerning the study of central collisions in 58Ni+48Ca reactions at Elab(Ni=25 AMeV are presented. The experimental data, collected with the CHIMERA 4π device, have been analyzed in order to investigate the competition among different reaction mechanisms for central collisions in the Fermi energy domain. The method adopted to perform the centrality selection refers to the global variable “flow angle”, that is related to the event shape in momentum space, as it is determined by the eigenvectors of the experimental kinetic-energy tensor. The main features of the reaction products were explored by using different constraints on some of the relevant observables, such as mass and velocity distributions and their correlations. Much emphasis was devoted to the competition between fusion-evaporation processes with subsequent identification of a heavy residue and a prompt multifragmentation mechanism. The reaction mechanism was simulated in the framework of transport theories (dynamical stochastic BNV calculations, followed by sequential SIMON code and further comparison with dynamical calculations from transport model (QMD, CoMD are in progress. Moreover, an extension of this study taking into account for the light particles has been envisaged.

  7. Control of ciliary motility by Ca2+: Integration of Ca2+-dependent functions and targets for Ca2+ action

    International Nuclear Information System (INIS)

    Evans, T.C.

    1988-01-01

    To identify functions that regulate Ca 2+ -induced ciliary reversal in Paramecium, mutants defective in terminating depolarization-induced backward swimming were selected. Six independent recessive mutations (k-shy) comprising two complementation groups, k-shyA and k-shyB, were identified. All mutants exhibited prolonged backward swimming in depolarizing solutions. Voltage clamp studies revealed that mutant Ca 2+ current amplitudes were reduced, but could be restored to wild type levels by EGTA injection. The recovery of the mutant Ca 2+ current from Ca 2+ -dependent inactivation, and the decay of the Ca 2+ -dependent K + and Ca 2+ -dependent Na + currents after depolarization were slow in k-shy compared to wild type. To identify protein targets of Ca 2+ action, ciliary proteins that interact with calmodulin (CaM) were characterized. With a 125 I-CaM blot assay, several CaM-binding proteins were identified including axonemal, soluble, and membrane-bound polypeptides. Competitive displacement studies with unlabeled Paramecium CaM, bovine CaM, and troponinC suggested that both protein types bind CaM with high affinity and specificity. To examine the presence of CaM-binding sites in intact axonemes, a filtration binding assay was developed

  8. Ultra-High Intensity Proton Accelerators and their Applications

    International Nuclear Information System (INIS)

    Weng, W. T.

    1997-01-01

    The science and technology of proton accelerators have progressed considerably in the past three decades. Three to four orders of magnitude increase in both peak intensity and average flux have made it possible to construct high intensity proton accelerators for modern applications, such as: spallation neutron sources, kaon factory, accelerator production of tritium, energy amplifier and muon collider drivers. The accelerator design focus switched over from intensity for synchrotrons, to brightness for colliders to halos for spallation sources. An overview of this tremendous progress in both accelerator science and technology is presented, with special emphasis on the new challenges of accelerator physics issues such as: H(-) injection, halo formation and reduction of losses

  9. Evidence based exercise - clinical benefits of high intensity interval training.

    Science.gov (United States)

    Shiraev, Tim; Barclay, Gabriella

    2012-12-01

    Aerobic exercise has a marked impact on cardiovascular disease risk. Benefits include improved serum lipid profiles, blood pressure and inflammatory markers as well as reduced risk of stroke, acute coronary syndrome and overall cardiovascular mortality. Most exercise programs prescribed for fat reduction involve continuous, moderate aerobic exercise, as per Australian Heart Foundation clinical guidelines. This article describes the benefits of exercise for patients with cardiovascular and metabolic disease and details the numerous benefits of high intensity interval training (HIIT) in particular. Aerobic exercise has numerous benefits for high-risk populations and such benefits, especially weight loss, are amplified with HIIT. High intensity interval training involves repeatedly exercising at a high intensity for 30 seconds to several minutes, separated by 1-5 minutes of recovery (either no or low intensity exercise). HIT is associated with increased patient compliance and improved cardiovascular and metabolic outcomes and is suitable for implementation in both healthy and 'at risk' populations. Importantly, as some types of exercise are contraindicated in certain patient populations and HIIT is a complex concept for those unfamiliar to exercise, some patients may require specific assessment or instruction before commencing a HIIT program.

  10. Entrepreneurship in high-tech and knowledge-intensive sectors

    DEFF Research Database (Denmark)

    Christensen, Patrizia V.; Madsen, Henning; Neergaard, Helle

    development of new enterprises in high-tech and knowledge-intensive sectors are analysed in relation to the educational and professional background of the entrepreneur/entrepreneurial team, as well as the personal and professional social networks of the entrepreneurs. The analysis is based on a theoretical...... framework combining theories of human and social capital. Secondary aspects addressed in the research project are questions of male vs. female entrepreneurship, internationalisation-globalisation, and business success/failure.......The paper investigates key factors influencing the establishment and early growth of high-tech and knowledge-intensive new firms in Denmark. Particular attention is paid to the human and social variables affecting the creation, survival, and growth of such firms. The establishment and subsequent...

  11. Measurement of high-power microwave pulse under intense ...

    Indian Academy of Sciences (India)

    Abstract. KALI-1000 pulse power system has been used to generate single pulse nanosecond duration high-power microwaves (HPM) from a virtual cathode oscillator. (VIRCATOR) device. HPM power measurements were carried out using a transmitting– receiving system in the presence of intense high frequency (a few ...

  12. [Effects of Ca2+ on nitric oxide-induced adventitious rooting in cucumber under drought stress].

    Science.gov (United States)

    Li, Chun Lan; Niu, Li Juan; Hu, Lin Li; Liao, Wei Biao; Chen, Yue

    2017-11-01

    Cucumber (Cucumis sativus L. 'Xinchun 4') was used to explore the relationship between nitric oxide (NO) and calcium (Ca 2+ ) during adventitious rooting under drought stress. Rooting parameters, endogenous Ca 2+ fluorescent intensity and the antioxidant enzymes activity (SOD, CAT and APX) in cucumber explants under drought stress were investigated. The results showed that treatment with 200 μmol·L -1 CaCl 2 and 0.05% PEG significantly improved the number and length of adventitious root in cucumber explants under drought stress, while the application of Ca 2+ chelating agent (EGTA) and channel inhibitor (BAPTA/AM) significantly decreased NO-induced number and length of adventitious root under drought stress. Under drought stress, the fluorescence intensity of Ca 2+ in hypocotyls treated with NO and CaCl 2 was improved, however, the Ca 2+ fluorescence intensity in the hypocotyls treated with NO scavenger (cPTIO) was significantly lower than that in the hypocotyls treated with NO. Under drought stress, the activities of antioxidant enzymes in the cucumber explants were significantly promoted by the treatments with NO and CaCl 2 , however, Ca 2+ chelating agent and channel inhibitor significantly decreased the activity of antioxidant enzymes induced by NO. In conclusion, Ca 2+ might be involved in the process of NO-adjusted antioxidant enzymes activity during adventitious rooting under drought stress, which alleviated the negative effects of drought on the adventitious rooting and promoted the formation of adventitious roots.

  13. Surface chemical reactions during electron beam irradiation of nanocrystalline CaS:Ce3+ phosphor

    International Nuclear Information System (INIS)

    Kumar, Vinay; Pitale, Shreyas S.; Nagpure, I. M.; Coetsee, E.; Ntwaeaborwa, O. M.; Terblans, J. J.; Swart, H. C.; Mishra, Varun

    2010-01-01

    The effects of accelerating voltage (0.5-5 keV) on the green cathodoluminescence (CL) of CaS:Ce 3+ nanocrystalline powder phosphors is reported. An increase in the CL intensity was observed from the powders when the accelerating voltage was varied from 0.5 to 5 keV, which is a relevant property for a phosphor to be used in field emission displays (FEDs). The CL degradation induced by prolonged electron beam irradiation was analyzed using CL spectroscopy, x-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES). The AES data showed the decrease in the S peak intensity and an increase in the O peak intensity during electron bombardment. The CL intensity was found to decrease to 30% of its original intensity after about 50 C/cm 2 . XPS was used to study the chemical composition of the CaS:Ce 3+ nanophosphor before and after degradation. The XPS data confirms that a nonluminescent CaSO 4 layer has formed on the surface during the degradation process, which may partially be responsible for the CL degradation. The electron stimulated surface chemical reaction mechanism was used to explain the effects of S desorption and the formation of the nonluminescent CaSO 4 layer on the surface.

  14. Proceedings of the third ICFA mini-workshop on high intensity, high brightness hadron accelerators

    International Nuclear Information System (INIS)

    Roser, T.

    1997-01-01

    The third mini-workshop on high intensity, high brightness hadron accelerators was held at Brookhaven National Laboratory on May 7-9, 1997 and had about 30 participants. The workshop focussed on rf and longitudinal dynamics issues relevant to intense and/or bright hadron synchrotrons. A plenary session was followed by four sessions on particular topics. This document contains copies of the viewgraphs used as well as summaries written by the session chairs

  15. Title: Accelerator Test of an Angle Detecting Inclined Sensor (ADIS) Prototype with Beams of 48Ca and Fragments

    Science.gov (United States)

    Connell, J. J.; Lopate, C.; McKibben, R. B.; Enman, A.

    2006-12-01

    The measurement and identification of high energy ions (> few MeV/n) from events originating on the Sun is of direct interest to the Living With a Star Program. These ions are a major source of Single Event Effects (SEE) in space-based electronics. Measurements of these ions also help in understanding phenomena such as Solar particle events and coronal mass ejections. These disturbances can directly affect the Earth and the near-Earth space environment, and thus human technology. The resource constraints on spacecraft generally mean that instruments that measure cosmic rays and Solar energetic particles must have low mass (a few kg) and power (a few W), be robust and reliable yet highly capable. Such instruments should identify ionic species (at least by element, preferably by isotope) from protons through the iron group. The charge and mass resolution of heavy ion instrument in space depends upon determining ions' angles of incidence. The Angle Detecting Inclined Sensor (ADIS) system is a highly innovative and uniquely simple detector configuration used to determine the angle of incidence of heavy ions in space instruments. ADIS replaces complex position sensing detectors (PSDs) with a system of simple, reliable and robust Si detectors inclined at an angle to the instrument axis. In August 2004 we tested ADIS prototypes with a 48Ca beam at the National Superconducting Cyclotron Laboratory's (NSCL) Coupled Cyclotron Facility (CCF). We demonstrate that our prototype charged particle instrument design with an ADIS system has a charge resolution of better than 0.25 e. An ADIS based system is being incorporated into the Energetic Heavy Ion Sensor (EHIS), one of the instruments in the Space Environment In-Situ Suite (SEISS) on the next generation of Geostationary Operational Environmental Satellite (GOES-R) System. An ADIS based system was also selected for the High Energy Particle Sensor (HEPS), one of the instruments in the Space Environment Sensor Suite (SESS) on the

  16. High intensity physical exercise and pain in the neck and upper limb among slaughterhouse workers

    DEFF Research Database (Denmark)

    Sundstrup, Emil; Jakobsen, Markus D.; Andersen, Kenneth Jay

    2014-01-01

    and pain among 595 slaughterhouse workers in Denmark, Europe. Using logistic regression analyses, odds ratios for pain and work disability as a function of physical exercise, gender, age, BMI, smoking, and job position were estimated. The prevalence of pain in the neck, shoulder, elbow, and hand...... about the effect among workers with repetitive and forceful work demands. Before performing randomized controlled trials it may be beneficial to assess the cross-sectional connection between exercise and musculoskeletal pain. We investigated the association between high intensity physical exercise....../wrist was 48%, 60%, 40%, and 52%, respectively. The odds for experiencing neck pain were significantly lower among slaughterhouse workers performing physical exercise (OR = 0.70, CI: 0.49-0.997), whereas the odds for pain in the shoulders, elbow, or hand/wrist were not associated with exercise. The present...

  17. P-West High Intensity Secondary Beam Area Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Cox, A.; Currier, R.; Eartly, D.; Guthke, A.; Johnson, G.; Lee, D.; Dram, R.; Villegas, E.; Rest, J.; Tilles, E.; Vander Arend, P.

    1977-03-01

    This report gives the initial design parameters of a 1000 GeV High Intensity Superconducting Secondary Beam Laboratory to be situated in the Proton Area downstream of the existing Proton West experimental station. The area will provide Fermilab with a major capability for experimentation with pion and antiproton beams of intensities and of energies available at no other laboratory and with an electron beam with excellent spot size, intensity, and purity at energies far above that available at electron machines. Detailed beam design, area layouts, and cost estimates are presented, along with the design considerations.

  18. Beam loss studies in high-intensity heavy-ion linacs

    International Nuclear Information System (INIS)

    Ostroumov, P.N.; Aseev, V.N.; Lessner, E.S.; Mustapha, B.

    2004-01-01

    A low beam-loss budget is an essential requirement for high-intensity machines and represents one of their major design challenges. In a high-intensity heavy-ion machine, losses are required to be below 1 W/m for hands-on-maintenance. The driver linac of the Rare Isotope Accelerator (RIA) is designed to accelerate beams of any ion to energies from 400 MeV per nucleon for uranium up to 950 MeV for protons with a beam power of up to 400 kW. The high intensity of the heaviest ions is achieved by acceleration of multiple-charge-state beams, which requires a careful beam dynamics optimization to minimize effective emittance growth and beam halo formation. For beam loss simulation purposes, large number of particles must be tracked through the linac. Therefore the computer code TRACK has been parallelized and calculations are being performed on the JAZZ cluster recently inaugurated at ANL. This paper discusses how this powerful tool is being used for simulations for the RIA project to help decide on the high-performance and cost-effective design of the driver linac

  19. Narrow spectral emission CaMoO{sub 4}: Eu{sup 3+}, Dy{sup 3+}, Tb{sup 3+} phosphor crystals for white light emitting diodes

    Energy Technology Data Exchange (ETDEWEB)

    Khanna, A. [Smart Lighting Engineering Research Center, 110, 8th Street, Troy, New York, 12180 (United States); Electrical, Computer and Systems Engineering Department, Rensselaer Polytechnic Institute, 110, 8th Street, Troy, New York, 12180 (United States); Dutta, P.S., E-mail: duttap@rpi.edu [Smart Lighting Engineering Research Center, 110, 8th Street, Troy, New York, 12180 (United States); Electrical, Computer and Systems Engineering Department, Rensselaer Polytechnic Institute, 110, 8th Street, Troy, New York, 12180 (United States)

    2013-02-15

    Alkaline earth metal molybdates are promising candidates as a host material for high efficiency narrow spectral emission phosphors. These phosphors could potentially be used for the fabrication of phosphor-converted light emitting diodes (pc-LEDs). Phosphor crystals of calcium molybdate doped with rare earth dopant Ln{sup 3+}(Ln=Eu, Dy, Tb) grown using flux growth method have been shown to exhibit higher excitation efficiency than the powders synthesized by solid-state reaction process. Molybdenum (VI) oxide has been found to be a suitable flux for growing large size optically transparent high quality crystals at a temperature around 1100 Degree-Sign C. Using the excitation wavelengths of 465 nm, 454 nm and 489 nm for CaMoO{sub 4}: Eu{sup 3+}, CaMoO{sub 4}: Dy{sup 3+} and CaMoO{sub 4}: Tb{sup 3+}, respectively, intense emission lines at wavelengths of 615 nm, 575 nm and 550 nm were observed. The optimized doping concentrations of 12%, 2% and 5% for Eu{sup 3+}, Dy{sup 3+} and Tb{sup 3+}, respectively, provided the highest luminescence intensity. - Graphical Abstract: CaMoO{sub 4}: Eu{sup 3+} phosphor crystals grown using a molybdenum (VI) oxide flux exhibited around 1.5 times the emission intensity of powders obtained from solid-state reaction at the same synthesis temperature. These crystals were found to efficiently emit 615 nm red light when excited by near UV light up to a wavelength of 395 nm. Highlights: Black-Right-Pointing-Pointer CaMoO{sub 4}: Ln{sup 3+} (Ln=Eu{sup 3+}, Dy{sup 3+}, Tb{sup 3+}) phosphor crystals were successfully grown using high temperature flux (solutions) containing molybdenum (VI) oxide or lithium chloride. Black-Right-Pointing-Pointer Narrow spectral emission at 615 nm, 575 nm and 550 nm, respectively, was observed from CaMoO{sub 4}: Ln{sup 3+} (Ln=Eu{sup 3+}, Dy{sup 3+}, Tb{sup 3+}) phosphor crystals. Black-Right-Pointing-Pointer The optimized doping concentrations of Eu{sup 3+}, Dy{sup 3+}, Tb{sup 3+} in CaMoO{sub 4} for highest

  20. Enhancement of High-Intensity Focused Ultrasound Heating by Short-Pulse Generated Cavitation

    Directory of Open Access Journals (Sweden)

    Shin Yoshizawa

    2017-03-01

    Full Text Available A target tissue can be thermally coagulated in high-intensity focused ultrasound (HIFU treatment noninvasively. HIFU thermal treatments have been clinically applied to various solid tumors. One of the problems in HIFU treatments is a long treatment time. Acoustically driven microbubbles can accelerate the ultrasonic heating, resulting in the significant reduction of the treatment time. In this paper, a method named “trigger HIFU exposure” which employs cavitation microbubbles is introduced and its results are reviewed. A trigger HIFU sequence consists of high-intensity short pulses followed by moderate-intensity long bursts. Cavitation bubbles induced in a multiple focal regions by rapidly scanning the focus of high-intensity pulses enhanced the temperature increase significantly and produced a large coagulation region with high efficiency.

  1. Nonlinear behavior in high-intensity discharge lamps

    NARCIS (Netherlands)

    Baumann, Bernd; Schwieger, Joerg; Wolff, Marcus; Manders, Freddy; Suijker, Jos

    2016-01-01

    The light flicker problem of high intensity discharge lamps is studied numerically and experimentally. It is shown that in some respects the systems behave very similar to the forced Duffing oscillator with a softening spring. In particular, the jump phenomenon and hysteresis are observed in the

  2. Chrome tannage using high-intensity ultrasonic field.

    Science.gov (United States)

    Mäntysalo, E; Marjoniemi, M; Kilpeläinen, M

    1997-04-01

    The process time in chrome tannage in leather making, using an elastic compression cycle followed by irradiation by high-intensity ultrasound, is quite short lasting only a few minutes, compared with a process time of several hours in modern chrome tannage. After ultrasonic irradiation, samples were basified in 17 h in chrome liquor at a pH of 4.0 and the shrinkage temperature was measured. The determination of the efficiency for the chrome liquor penetrating into the hides can be based on the steepness of the shrinkage temperature-processing time curve. An approximate value of 20 degrees C min(-1) can be evaluated for the initial slope of the curve when elastic compression and high-intensity ultrasonic irradiation is used, and a processing time of 2 min is required in chrome liquor (plus 17 h basification and 24 h storage time) to obtain leather stable to boiling. Usually, hides are kept in chrome liquor for 2 h.

  3. Bright upconversion luminescence and increased Tc in CaBi2Ta2O9:Er high temperature piezoelectric ceramics

    International Nuclear Information System (INIS)

    Peng Dengfeng; Wang Xusheng; Yao Xi; Xu Chaonan; Lin Jian; Sun Tiantuo

    2012-01-01

    Er 3+ doped CaBi 2 Ta 2 O 9 (CBT) bismuth layered-structure high temperature piezoelectric ceramics were synthesized by the traditional solid state method. The upconversion (UC) emission properties of Er 3+ doped CBT ceramics were investigated as a function of Er 3+ concentration and incident pump power. A bright green upconverted emission was obtained under excitation 980 nm at room temperature. The observed strong green and weak red emission bands corresponded to the transitions from 4 S 3/2 and 4 F 9/2 to 4 I 15/2 , respectively. The dependence of UC emission intensity on pumping power indicated that a three-photon process was involved in UC emissions. Studies of dielectric with temperature have also been carried out. Introduction of Er increased the Curie temperature of CBT, thus, making this ceramic suitable for sensor applications at higher temperatures. Because of its strong up-converted emission and increased Tc, the multifunctional high temperature piezoelectric ceramic may be useful in high temperature sensor, fluorescence thermometry, and optical-electro integration applications.

  4. High-intensity discharge lamp and Duffing oscillator—Similarities and differences

    Science.gov (United States)

    Baumann, Bernd; Schwieger, Joerg; Stein, Ulrich; Hallerberg, Sarah; Wolff, Marcus

    2017-12-01

    The processes inside the arc tube of high-intensity discharge lamps are investigated using finite element simulations. The behavior of the gas mixture inside the arc tube is governed by differential equations describing mass, energy, and charge conservation, as well as the Helmholtz equation for the acoustic pressure and the Reynolds equations for the flow driven by buoyancy and Reynolds stresses. The model is highly nonlinear and requires a recursion procedure to account for the impact of acoustic streaming on the temperature and other fields. The investigations reveal the presence of a hysteresis and the corresponding jump phenomenon, quite similar to a Duffing oscillator. The similarities and, in particular, the differences of the nonlinear behavior of the high-intensity discharge lamp to that of a Duffing oscillator are discussed. For large amplitudes, the high-intensity discharge lamp exhibits a stiffening effect in contrast to the Duffing oscillator. It is speculated on how the stiffening might affect hysteresis suppression.

  5. Effect of high-intensity focused ultrasound (HIFU combined with radiotherapy on tumor malignancy in patients with advanced pancreatic cancer and evaluation of side effects

    Directory of Open Access Journals (Sweden)

    Jing Li

    2017-02-01

    Full Text Available Objective: To study the effect of high-intensity focused ultrasound (HIFU combined with radiotherapy on tumor malignancy in patients with advanced pancreatic cancer and the corresponding side effects. Methods: A total of 84 patients with advanced pancreatic cancer treated in our hospital between May 2013 and March 2016 were selected and randomly divided into HIFU group and IGRT group, HIFU group accepted high-intensity focused ultrasound combined with radiotherapy and IGRT group received radiotherapy alone. 4 weeks after treatment, the levels of tumor markers, liver and kidney function indexes, perineural invasionrelated molecules and cytokines in serum as well as the levels of immune cells in peripheral blood were determined. Results: 4 weeks after treatment, serum CA199, CA242, OPN, NGAL, RBP4, NGF, TrkA, p75, BDNF and TrkB levels of HIFU group were significantly lower than those of IGRT group, serum IL-2, TNF-毩, IFN-γ and IL-13 levels as well as peripheral blood NKT cell and CD4+T cell levels were significantly higher than those of IGRT group, and serum ALT, AST, Cr and BUN levels were not significantly different from those of IGRT group. Conclusion: HIFU combined with radiotherapy treatment of advanced pancreatic cancer can more effectively kill cancer cells, inhibit pancreatic cancer cell invasion to the peripheral nerve and enhance the antitumor immune response mediated by NKT cells and CD4+T cells.

  6. High-Intensity High-order Harmonics Generated from Low-Density Plasma

    International Nuclear Information System (INIS)

    Ozaki, T.; Bom, L. B. Elouga; Abdul-Hadi, J.; Ganeev, R. A.; Haessler, S.; Salieres, P.

    2009-01-01

    We study the generation of high-order harmonics from lowly ionized plasma, using the 10 TW, 10 Hz laser of the Advanced Laser Light Source (ALLS). We perform detailed studies on the enhancement of a single order of the high-order harmonic spectrum generated in plasma using the fundamental and second harmonic of the ALLS beam line. We observe quasi-monochromatic harmonics for various targets, including Mn, Cr, Sn, and In. We identify most of the ionic/neutral transitions responsible for the enhancement, which all have strong oscillator strengths. We demonstrate intensity enhancements of the 13th, 17th, 29th, and 33rd harmonics from these targets using the 800 nm pump laser and varying its chirp. We also characterized the attosecond nature of such plasma harmonics, measuring attosecond pulse trains with 360 as duration for chromium plasma, using the technique of ''Reconstruction of Attosecond Beating by Interference of Two-photon Transitions''(RABBIT). These results show that plasma harmonics are intense source of ultrashort coherent soft x-rays.

  7. A high affinity Ca2(+)-ATPase on the surface membrane of Leishmania donovani promastigote

    International Nuclear Information System (INIS)

    Ghosh, J.; Ray, M.; Sarkar, S.; Bhaduri, A.

    1990-01-01

    A Ca2(+)-dependent ATP-hydrolytic activity was detected in the crude membrane ghost of the promastigote or vector form of the protozoal parasite Leishmania donovani, the pathogen responsible for kala azar. The Ca2(+)-ATPase was purified to apparent homogeneity after solubilization with deoxycholate. The enzyme consists of two subunits of Mr = 51,000 and 57,000 and has an apparent molecular weight of 215,000 +/- 12,000. The enzyme activity is exclusively dependent on Ca2+, and the pure enzyme can hydrolyze 1.6 mumol of ATP/min/mg of protein. The apparent Km for Ca2+ is 35 nM, which is further reduced to 12 nM in the presence of heterologous calmodulin. The enzyme is sensitive to vanadate, but is insensitive to oligomycin and ouabain. The enzyme is strongly associated with the plasma membrane and has its catalytic site oriented toward the cytoplasmic face. The enzyme spans across the plasma membrane as surface labeling with radioiodine shows considerable radioactivity in the completely purified enzyme. The localization and orientation of this high affinity, calmodulin-sensitive Ca2(+)-ATPase suggest some role of this enzyme in Ca2+ movement in the life cycle of this protozoal parasite

  8. A high affinity Ca2(+)-ATPase on the surface membrane of Leishmania donovani promastigote

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, J.; Ray, M.; Sarkar, S.; Bhaduri, A. (Indian Institute of Chemical Biology, Calcutta (India))

    1990-07-05

    A Ca2(+)-dependent ATP-hydrolytic activity was detected in the crude membrane ghost of the promastigote or vector form of the protozoal parasite Leishmania donovani, the pathogen responsible for kala azar. The Ca2(+)-ATPase was purified to apparent homogeneity after solubilization with deoxycholate. The enzyme consists of two subunits of Mr = 51,000 and 57,000 and has an apparent molecular weight of 215,000 +/- 12,000. The enzyme activity is exclusively dependent on Ca2+, and the pure enzyme can hydrolyze 1.6 mumol of ATP/min/mg of protein. The apparent Km for Ca2+ is 35 nM, which is further reduced to 12 nM in the presence of heterologous calmodulin. The enzyme is sensitive to vanadate, but is insensitive to oligomycin and ouabain. The enzyme is strongly associated with the plasma membrane and has its catalytic site oriented toward the cytoplasmic face. The enzyme spans across the plasma membrane as surface labeling with radioiodine shows considerable radioactivity in the completely purified enzyme. The localization and orientation of this high affinity, calmodulin-sensitive Ca2(+)-ATPase suggest some role of this enzyme in Ca2+ movement in the life cycle of this protozoal parasite.

  9. Crystal growth and optical properties of Sm:CaNb2O6 single crystal

    International Nuclear Information System (INIS)

    Di Juqing; Xu Xiaodong; Xia Changtai; Zeng Huidan; Cheng Yan; Li Dongzhen; Zhou Dahua; Wu Feng; Cheng Jimeng; Xu Jun

    2012-01-01

    Highlights: ► Sm:CaNb 2 O 6 single crystal was grown by the Czochralski method. ► Thermal expansion coefficients and J–O parameters were calculated. ► We found that this crystal had high quantum efficiency of 97%. - Abstract: Sm:CaNb 2 O 6 single crystal has been grown by the Czochralski method. Its high-temperature X-ray powder diffraction, optical absorption, emission spectroscopic as well as lifetime have been studied. Thermal expansion coefficients (α), J–O parameters (Ω i ), radiative lifetime (τ rad ), branching ratios (β) and stimulated emission cross-sections (σ e ) were calculated. The quantum efficiency (η) was calculated to be 97%. The intense peak emission cross section at 610, 658 nm were calculated to be 2.40 × 10 −21 , 2.42 × 10 −21 cm 2 . These results indicate that Sm:CaNb 2 O 6 crystal has potential use in visible laser and photonic devices area.

  10. Physics of high intensity nanosecond electron source

    International Nuclear Information System (INIS)

    Herrera-Gomez, A.; Spicer, W.E.

    1993-08-01

    A new high-intensity, short-time electron source is now being used at the Stanford Linear Accelerator Center (SLAC). Using a GaAs negative affinity semiconductor in the construction of the cathode, it is possible to fulfill operation requirements such as peak currents of tens of amperes, peak widths of the order of nanoseconds, hundreds of hours of operation stability, and electron spin polarization. The cathode is illuminated with high intensity laser pulses, and photoemitted electrons constitute the yield. Because of the high currents, some nonlinear effects are present. Very noticeable is the so-called Charge Limit (CL) effect, which consists of a limit on the total charge in each pulse-that is, the total bunch charge stops increasing as the light pulse total energy increases. In this paper, we explain the mechanism of the CL and how it is caused by the photovoltaic effect. Our treatment is based on the Three-Step model of photoemission. We relate the CL to the characteristics of the surface and bulk of the semiconductor, such as doping, band bending, surface vacuum level, and density of surface states. We also discuss possible ways to prevent the Char's Level effect

  11. Preparation and photoelectric properties of p-CaFe2O4/n-WO3 composites

    International Nuclear Information System (INIS)

    Wan, Ruiqin; Jia, Caihong; Zhang, Weifeng

    2012-01-01

    Highlights: ► Surface photovoltage spectroscopy investigation on p-CaFe 2 O 4 /n-WO 3 composites. ► The photovoltaic response is enhanced in p-CaFe 2 O 4 /n-WO 3 composites. ► The multielectron process and high rate of carrier migration in WO 3 . - Abstract: Composites of p-CaFe 2 O 4 /n-WO 3 are prepared via a sol–gel technique. Their structures and optical properties are characterized with X-ray diffraction, scanning electron microscopy and UV–vis absorption spectroscopy. The photoelectric characteristics are investigated by surface photovoltage spectroscopy combined with electric field induced surface photovoltage spectroscopy. The results indicate that CaFe 2 O 4 can well form a p–n type composite with WO 3 , and the intensity and spectral region of surface photovoltaic response for the composites are strongly dependent on the molar ratio of two components. The enhancement in photoelectric properties and the effective separation of photogenerated carriers could be attributed to the energy level matching between the two components, multielectron process and the high migration rate in WO 3 .

  12. High-intensity interval running is perceived to be more enjoyable than moderate-intensity continuous exercise: implications for exercise adherence.

    Science.gov (United States)

    Bartlett, Jonathan D; Close, Graeme L; MacLaren, Don P M; Gregson, Warren; Drust, Barry; Morton, James P

    2011-03-01

    The aim of this study was to objectively quantify ratings of perceived enjoyment using the Physical Activity Enjoyment Scale following high-intensity interval running versus moderate-intensity continuous running. Eight recreationally active men performed two running protocols consisting of high-intensity interval running (6 × 3 min at 90% VO(2max) interspersed with 6 × 3 min active recovery at 50% VO(2max) with a 7-min warm-up and cool down at 70% VO(2max)) or 50 min moderate-intensity continuous running at 70% VO(2max). Ratings of perceived enjoyment after exercise were higher (P running compared with continuous running (88 ± 6 vs. 61 ± 12) despite higher (P running may be relevant for improving exercise adherence, since running is a low-cost exercise intervention requiring no exercise equipment and similar relative exercise intensities have previously induced health benefits in patient populations.

  13. Short-term effects of implemented high intensity shoulder elevation during computer work

    DEFF Research Database (Denmark)

    Larsen, Mette K.; Samani, Afshin; Madeleine, Pascal

    2009-01-01

    computer work to prevent neck-shoulder pain may be possible without affecting the working routines. However, the unexpected reduction in clavicular trapezius rest during a pause with preceding high intensity contraction requires further investigation before high intensity shoulder elevations can......BACKGROUND: Work-site strength training sessions are shown effective to prevent and reduce neck-shoulder pain in computer workers, but difficult to integrate in normal working routines. A solution for avoiding neck-shoulder pain during computer work may be to implement high intensity voluntary...... contractions during the computer work. However, it is unknown how this may influence productivity, rate of perceived exertion (RPE) as well as activity and rest of neck-shoulder muscles during computer work. The aim of this study was to investigate short-term effects of a high intensity contraction...

  14. Novel and easy access to highly luminescent Eu and Tb doped ultra-small CaF2, SrF2 and BaF2 nanoparticles - structure and luminescence.

    Science.gov (United States)

    Ritter, Benjamin; Haida, Philipp; Fink, Friedrich; Krahl, Thoralf; Gawlitza, Kornelia; Rurack, Knut; Scholz, Gudrun; Kemnitz, Erhard

    2017-02-28

    A universal fast and easy access at room temperature to transparent sols of nanoscopic Eu 3+ and Tb 3+ doped CaF 2 , SrF 2 and BaF 2 particles via the fluorolytic sol-gel synthesis route is presented. Monodisperse quasi-spherical nanoparticles with sizes of 3-20 nm are obtained with up to 40% rare earth doping showing red or green luminescence. In the beginning luminescence quenching effects are only observed for the highest content, which demonstrates the unique and outstanding properties of these materials. From CaF 2 :Eu10 via SrF 2 :Eu10 to BaF 2 :Eu10 a steady increase of the luminescence intensity and lifetime occurs by a factor of ≈2; the photoluminescence quantum yield increases by 29 to 35% due to the lower phonon energy of the matrix. The fast formation process of the particles within fractions of seconds is clearly visualized by exploiting appropriate luminescence processes during the synthesis. Multiply doped particles are also available by this method. Fine tuning of the luminescence properties is achieved by variation of the Ca-to-Sr ratio. Co-doping with Ce 3+ and Tb 3+ results in a huge increase (>50 times) of the green luminescence intensity due to energy transfer Ce 3+ → Tb 3+ . In this case, the luminescence intensity is higher for CaF 2 than for SrF 2 , due to a lower spatial distance of the rare earth ions.

  15. High-spin states in the A=39 mirror nuclei 39Ca and 39K

    International Nuclear Information System (INIS)

    Andersson, T.; Rudolph, D.; Fahlander, C.; Eberth, J.; Thomas, H.G.; Haslip, D.; Svensson, C.E.; Waddington, J.C.; LaFosse, D.R.; Sarantites, D.G.; Weintraub, W.; Wilson, J.N.; Brown, B.A.

    1999-01-01

    High-spin states of the mass A=39 mirror pair 39 K and 39 Ca were investigated via the fusion-evaporation reaction 28 Si+ 16 O at 125 MeV beam energy. The gammasphere array in conjunction with the 4π charged-particle detector array microball and neutron detectors was used to detect γ rays in coincidence with evaporated light particles. The results of the first high-spin study of the T z =-1/2 nucleus 39 Ca are discussed in terms of mirror symmetry and compared to spherical shell-model calculations in the 1d 3/2 -1f 7/2 configuration space. (orig.)

  16. Dynamics of Cavitation Clouds within a High-Intensity Focused Ultrasonic Beam

    Science.gov (United States)

    2012-03-01

    the cloud size. I. INTRODUCTION High-intensity focused ultrasound (HIFU), along with the associated cavitation , is used in a variety of fields. The...Article 3. DATES COVERED (From - To) March 2012- May 2012 4. TITLE AND SUBTITLE Dynamics of Cavitation Clouds within a High-Intensity Focused...in initially quiescent water. The resulting pressure field and behavior of the cavitation bubbles are measured using high-speed digital in-line

  17. Greater effects of high- compared with moderate-intensity interval training on cardio-metabolic variables, blood leptin concentration and ratings of perceived exertion in obese adolescent females.

    Science.gov (United States)

    Racil, G; Coquart, J B; Elmontassar, W; Haddad, M; Goebel, R; Chaouachi, A; Amri, M; Chamari, K

    2016-06-01

    This study examined the effects of high- vs. moderate-intensity interval training on cardiovascular fitness, leptin levels and ratings of perceived exertion (RPE) in obese female adolescents. Forty-seven participants were randomly assigned to one of three groups receiving either a 1:1 ratio of 15 s of effort comprising moderate-intensity interval training (MIIT at 80% maximal aerobic speed: MAS) or high-intensity interval training (HIIT at 100% MAS), with matched 15 s recovery at 50% MAS, thrice weekly, or a no-training control group. The HIIT and MIIT groups showed improved (p HIIT group showed decreased waist circumference (WC) (p = 0.017). The effect of exercise on maximal oxygen uptake (VO2max) was significant (p = 0.019, ES = 0.48 and p = 0.010, ES = 0.57, HIIT and MIIT, respectively). The decrease of rate-pressure product (RPP) (p HIIT and MIIT, respectively) followed the positive changes in resting heart rate and blood pressures. Blood glucose, insulin level and the homeostasis model assessment index for insulin decreased (p HIIT and MIIT, respectively. In the post-intervention period, blood leptin was strongly associated with %BF (p HIIT and MIIT groups, respectively, while RPE was strongly associated with BM (p HIIT group. The results suggest that high-intensity interval training may produce more positive effects on health determinants in comparison with the same training mode at a moderate intensity.

  18. Nonlinear behavior in high-intensity discharge lamps

    Science.gov (United States)

    Baumann, Bernd; Schwieger, Joerg; Wolff, Marcus; Manders, Freddy; Suijker, Jos

    2016-06-01

    The light flicker problem of high intensity discharge lamps is studied numerically and experimentally. It is shown that in some respects the systems behave very similar to the forced Duffing oscillator with a softening spring. In particular, the jump phenomenon and hysteresis are observed in the simulations and in the experiments.

  19. Tolerable Beam Loss at High-Intensity Machines

    International Nuclear Information System (INIS)

    Krivosheev, Oleg E.; Mokhov, Nikolai V.

    2000-01-01

    Tolerable beam losses are estimated for high-intensity ring accelerators with proton energy of 3 to 16 GeV. Dependence on beam energy, lattice and magnet geometry is studied via full Monte Carlo MARS14 simulations in lattice elements, shielding, tunnel and surrounding dirt with realistic geometry, materials and magnetic fields

  20. High-intensity intermittent swimming improves cardiovascular health status for women with mild hypertension

    DEFF Research Database (Denmark)

    Mohr, Magni; Nordsborg, Nikolai Baastrup; Lindenskov, Annika

    2014-01-01

    To test the hypothesis that high-intensity swim training improves cardiovascular health status in sedentary premenopausal women with mild hypertension, sixty-two women were randomized into high-intensity (n = 21; HIT), moderate-intensity (n = 21; MOD), and control groups (n = 20; CON). HIT perfor...

  1. Enhanced high harmonic generation driven by high-intensity laser in argon gas-filled hollow core waveguide

    International Nuclear Information System (INIS)

    Cassou, Kevin; Daboussi, Sameh; Hort, Ondrej; Descamps, Dominique; Petit, Stephane; Mevel, Eric; Constant, Eric; Guilbaud, Oilvier; Kazamias, Sophie

    2014-01-01

    We show that a significant enhancement of the photon flux produced by high harmonic generation can be obtained through guided configuration at high laser intensity largely above the saturation intensity. We identify two regimes. At low pressure, we observe an intense second plateau in the high harmonic spectrum in argon. At relatively high pressure, complex interplay between strongly time-dependent ionization processes and propagation effects leads to important spectral broadening without loss of spectral brightness. We show that the relevant parameter for this physical process is the product of laser peak power by gas pressure. We compare source performances with high harmonic generation using a gas jet in loose focusing geometry and conclude that the source developed is a good candidate for injection devices such as seeded soft x-ray lasers or free electron lasers in the soft x-ray range. (authors)

  2. High-intensity erotic visual stimuli de-activate the primary visual cortex in women.

    Science.gov (United States)

    Huynh, Hieu K; Beers, Caroline; Willemsen, Antoon; Lont, Erna; Laan, Ellen; Dierckx, Rudi; Jansen, Monique; Sand, Michael; Weijmar Schultz, Willibrord; Holstege, Gert

    2012-06-01

    The primary visual cortex, Brodmann's area (BA 17), plays a vital role in basic survival mechanisms in humans. In most neuro-imaging studies in which the volunteers have to watch pictures or movies, the primary visual cortex is similarly activated independent of the content of the pictures or movies. However, in case the volunteers perform demanding non-visual tasks, the primary visual cortex becomes de-activated, although the amount of incoming visual sensory information is the same. Do low- and high-intensity erotic movies, compared to neutral movies, produce similar de-activation of the primary visual cortex? Brain activation/de-activation was studied by Positron Emission Tomography scanning of the brains of 12 healthy heterosexual premenopausal women, aged 18-47, who watched neutral, low- and high-intensity erotic film segments. We measured differences in regional cerebral blood flow (rCBF) in the primary visual cortex during watching neutral, low-intensity erotic, and high-intensity erotic film segments. Watching high-intensity erotic, but not low-intensity erotic movies, compared to neutral movies resulted in strong de-activation of the primary (BA 17) and adjoining parts of the secondary visual cortex. The strong de-activation during watching high-intensity erotic film might represent compensation for the increased blood supply in the brain regions involved in sexual arousal, also because high-intensity erotic movies do not require precise scanning of the visual field, because the impact is clear to the observer. © 2012 International Society for Sexual Medicine.

  3. Automated system for the determination of patterns of high-intensity LEDs

    International Nuclear Information System (INIS)

    Baly, L.; Bolaño, L.; Arteche, R.; Broco, Y.; Quesada, I.; Rodríguez, E.

    2008-01-01

    Determination of high-intensity LEDs lighting patterns is an important step for the simulation and planning of arrays of these devices configurations. Currently there are systems based on CCD cameras able to efficiently solve this problem, however the high cost of these is a limiting factor for use. Another limitation of CCD cameras, is that they are designed for light levels much lower than those produced by a high-intensity LED. In this paper we present an automated system for the determination of the intensity of LEDs based on the scan point to point patterns. The results of the analysis of a type of LED based on arrays of bars with built-in optical system is presented.

  4. Nuclear diagnostics of high intensity laser plasma interactions

    International Nuclear Information System (INIS)

    Krushelnick, K.; Santala, M.I.K.; Beg, F.N.; Clark, E.L.; Dangor, A.E.; Tatarakis, M.; Watts, I.; Wei, M.S.; Zepf, M.; Ledingham, K.W.D.; McCanny, T.; Spencer, I.; Clarke, R.J.; Norreys, P.A.

    2002-01-01

    Nuclear activation has been observed in materials exposed to energetic protons and heavy ions generated from high intensity laser-solid interactions (at focused intensities up to 5x10 19 W/cm 2 ). The energy spectrum of the protons is determined through the use of these nuclear activation techniques and is found to be consistent with other ion diagnostics. Heavy ion fusion reactions and large neutron fluxes from the (p, n) reactions were also observed. The reduction of proton emission and increase in heavy ion energy using heated targets was also observed

  5. Synthesis and characterization of Er3+ doped CaF2 nanoparticles

    International Nuclear Information System (INIS)

    Zhi Guanglin; Song Jinghong; Mei Bingchu; Zhou Weibing

    2011-01-01

    Highlights: → Er 3+ :CaF 2 nanoparticles were synthesized by co-precipitation method with particle size of 8-36 nm. → Increasing dopant concentration increases lattice constants and decreases grain size. → Annealing treatment has a remarkable effect on luminescence properties. → Luminescence intensity decrease with the increasing of the dopant concentration. - Abstract: Er 3+ doped CaF 2 nanoparticles were synthesized by a chemical co-precipitation method. Effect of the dopant concentrations on the structure and optical properties of the CaF 2 nanoparticles was investigated. The X-ray powder diffraction and transmission electron microscopy analysis was used to characterize the structure and morphology of the nanoparticles. The nanoparticles with different dopant concentration exhibited a sphere-like morphology with diameters of about 8-36 nm. The incorporation of Er 3+ ions into CaF 2 resulted in the decrease in grain size and deterioration of crystallinity, but enlarged the lattice constants of CaF 2 . Additional annealing treatment at 400 deg. C to the prepared CaF 2 removed the NO 3 - and OH - groups adsorbed on the particles' surfaces, and improved the optical properties of the nanoparticles. The fluorescence intensity, with a maximum at approximately 0.4 mol%, decreased with the increase in doping concentration because of concentration quenching.

  6. High-intensity interval training vs. moderate-intensity continuous training in the prevention/management of cardiovascular disease

    OpenAIRE

    Hussain, S; Macaluso, A; Pearson, S

    2016-01-01

    Moderate-intensity continuous training (MICT) has long been considered the most effective exercise treatment modality for the prevention and management of cardiovascular disease, but more recently high-intensity interval training (HIIT) has emerged into the clinical environment has been viewed as a potential alternative to MICT in accruing such benefits. HIIT was initially found to induce significant improvements in numerous physiological and health-related indices, to a similar if not superi...

  7. The High Luminosity Challenge: potential and limitations of High Intensity High Brightness in the LHC and its injectors

    CERN Document Server

    De Maria, R; Banfi, D; Barranco, J; Bartosik, H; Benedetto, E; Bruce, R; Brüning, O; Calaga, R; Cerutti, F; Damerau, H; Esposito, L; Fartoukh, S; Fitterer, M; Garoby, R; Gilardoni, S; Giovannozzi, M; Goddard, B; Gorini, B; Hanke, K; Iadarola, G; Lamont, M; Meddahi, M; Métral, E; Mikulec, B; Mounet, N; Papaphilippou, Y; Pieloni, T; Redaelli, S; Rossi, L; Rumolo, G; Shaposhnikova, E; Sterbini, G; Todesco, E; Tomás, R; Zimmermann, F; Valishev, A

    2014-01-01

    High-intensity and high-brightness beams are key ingredients to maximize the LHC integrated luminosity and to exploit its full potential. This contribution describes the optimization of beam and machine parameters to maximize the integrated luminosity as seen by the LHC experiments, by taking into account the expected intensity and brightness reach of LHC itself and its injector chain as well as the capabilities of the detectors for next run and foreseen upgrade scenarios.

  8. Super-Hydrophobic High Throughput Electrospun Cellulose Acetate (CA) Nanofibrous Mats as Oil Selective Sorbents

    Science.gov (United States)

    Han, Chao

    The threat of oil pollution increases with the expansion of oil exploration and production activities, as well as the industrial growth around the world. Use of sorbents is a common method to deal with the oil spills. In this work, an advanced sorbent technology is described. A series of non-woven Cellulose Acetate (CA) nanofibrous mats with a 3D fibrous structure were synthesized by a novel high-throughput electrospinning technique. The precursor was solutions of CA/ acetic acid-acetone in various concentrations. Among them, 15.0% CA exhibits a superhydrophobic surface property, with a water contact angle of 128.95°. Its oil sorption capacity is many times higher the oil sorption capacity of the best commercial sorbent available in the market. Also, it showed good buoyancy properties on the water both as dry-mat and oil-saturated mat. In addition, it is biodegradable, easily available, easily manufactured, so the CA nanofibrous mat is an excellent candidate as oil sorbent for oil spill in water treatment.

  9. Cell surface topology creates high Ca2+ signalling microdomains

    DEFF Research Database (Denmark)

    Brasen, Jens Christian; Olsen, Lars Folke; Hallett, Maurice B

    2010-01-01

    It has long been speculated that cellular microdomains are important for many cellular processes, especially those involving Ca2+ signalling. Measurements of cytosolic Ca2+ report maximum concentrations of less than few micromolar, yet several cytosolic enzymes require concentrations of more than...

  10. New experimental stopping power data of 4He, 16O, 40Ar, 48Ca and 84Kr projectiles in different solid materials

    Science.gov (United States)

    Trzaska, W. H.; Knyazheva, G. N.; Perkowski, J.; Andrzejewski, J.; Khlebnikov, S. V.; Kozulin, E. M.; Malkiewicz, T.; Mutterer, M.; Savelieva, E. O.

    2018-03-01

    New experimental data on energy loss of 4He, 16O, 40Ar, 48Ca and 84Kr ions in thin, self-supporting foils of C, Al, Ni, Ag, Lu, Au, Pb and Th are presented. The measurements, using the TOF-E method, were done in a very broad energy range around the stopping power maximum; typically from 0.1 to 11 MeV/u. When available, the extracted stopping power values are compared with the previously published data. The overall agreement is good although a fair comparison is difficult as the covered energy range is much larger than in previous measurements. The small error bars and a broad coverage allowed us to test the predictions of theoretical codes: PASS, CasP, and semi-empirical programs: SRIM, LET, MSTAR, and the Hubert table predictions. The deviations of PASS predictions from the experimental data do not exceed 20% for all the measured combinations. CasP predictions are within 15% from the data for heavier ions but diverge up to 40% for lighter ions. Semi-empirical approaches, including SRIM, deviate from the experimental data by less than 5% for the regions already covered by previous experiments but err by about 10-20% for the ion/target combinations that were not measured before: Ca in Lu as well as Kr in Lu, Pb, and Th.

  11. Collective Focusing of Intense Ion Beam Pulses for High-energy Density Physics Applications

    International Nuclear Information System (INIS)

    Dorf, Mikhail A.; Kaganovich, Igor D.; Startsev, Edward A.; Davidson, Ronald C.

    2011-01-01

    The collective focusing concept in which a weak magnetic lens provides strong focusing of an intense ion beam pulse carrying a neutralizing electron background is investigated by making use of advanced particle-in-cell simulations and reduced analytical models. The original analysis by Robertson Phys. Rev. Lett. 48, 149 (1982) is extended to the parameter regimes of particular importance for several high-energy density physics applications. The present paper investigates (1) the effects of non-neutral collective focusing in a moderately strong magnetic field; (2) the diamagnetic effects leading to suppression of the applied magnetic field due to the presence of the beam pulse; and (3) the influence of a finite-radius conducting wall surrounding the beam cross-section on beam neutralization. In addition, it is demonstrated that the use of the collective focusing lens can significantly simplify the technical realization of the final focusing of ion beam pulses in the Neutralized Drift Compression Experiment-I (NDCX-I), and the conceptual designs of possible experiments on NDCX-I are investigated by making use of advanced numerical simulations.

  12. Acute Elevated Glucose Promotes Abnormal Action Potential-Induced Ca2+ Transients in Cultured Skeletal Muscle Fibers

    Directory of Open Access Journals (Sweden)

    Erick O. Hernández-Ochoa

    2017-01-01

    Full Text Available A common comorbidity of diabetes is skeletal muscle dysfunction, which leads to compromised physical function. Previous studies of diabetes in skeletal muscle have shown alterations in excitation-contraction coupling (ECC—the sequential link between action potentials (AP, intracellular Ca2+ release, and the contractile machinery. Yet, little is known about the impact of acute elevated glucose on the temporal properties of AP-induced Ca2+ transients and ionic underlying mechanisms that lead to muscle dysfunction. Here, we used high-speed confocal Ca2+ imaging to investigate the temporal properties of AP-induced Ca2+ transients, an intermediate step of ECC, using an acute in cellulo model of uncontrolled hyperglycemia (25 mM, 48 h.. Control and elevated glucose-exposed muscle fibers cultured for five days displayed four distinct patterns of AP-induced Ca2+ transients (phasic, biphasic, phasic-delayed, and phasic-slow decay; most control muscle fibers show phasic AP-induced Ca2+ transients, while most fibers exposed to elevated D-glucose displayed biphasic Ca2+ transients upon single field stimulation. We hypothesize that these changes in the temporal profile of the AP-induced Ca2+ transients are due to changes in the intrinsic excitable properties of the muscle fibers. We propose that these changes accompany early stages of diabetic myopathy.

  13. Measurements of acoustic pressure at high amplitudes and intensities

    International Nuclear Information System (INIS)

    Crum, L A; Bailey, M R; Kaczkowski, P; McAteer, J A; Pishchalnikov, Y A; Sapozhnikov, O A

    2004-01-01

    In our research group, we desire measurements of the large pressure amplitudes generated by the shock waves used in shock wave lithotripsy (SWL) and the large acoustic intensities used in High Intensity Focused Ultrasound (HIFU). Conventional piezoelectric or PVDF hydrophones can not be used for such measurements as they are damaged either by cavitation, in SWL applications, or heat, in HIFU applications. In order to circumvent these difficulties, we have utilized optical fiber hydrophones in SWL that do not cavitate, and small glass probes and a scattering technique for measurements of large HIFU intensities. Descriptions of these techniques will be given as well as some typical data

  14. Physical conditions in CaFe interstellar clouds

    OpenAIRE

    Gnacinski, P.; Krogulec, M.

    2007-01-01

    Interstellar clouds that exhibit strong Ca I and Fe I lines were called CaFe clouds. The ionisation equilibrium equations were used to model the column densities of Ca II, Ca I, K I, Na I, Fe I and Ti II in CaFe clouds. The chemical composition of CaFe clouds is that of the Solar System and no depletion of elements onto dust grains is seen. The CaFe clouds have high electron densities n=1 cm^-3 that leads to high column densities of neutral Ca and Fe.

  15. Effects of endurance training on reduction of plasma glucose during high intensity constant and incremental speed tests in Wistar rats

    Directory of Open Access Journals (Sweden)

    P. Abreu

    Full Text Available The aim of this research was to investigate the effects of endurance training on reduction of plasma glucose during high intensity constant and incremental speed tests in Wistar rats. We hypothesized that plasma glucose might be decreased in the exercised group during heavy (more intense exercise. Twenty-four 10-week-old male Wistar rats were randomly assigned to sedentary and exercised groups. The prescription of endurance exercise training intensity was determined as 60% of the maximum intensity reached at the incremental speed test. The animals were trained by running on a motorized treadmill, five days/week for a total period of 67 weeks. Plasma glucose during the constant speed test in the exercised group at 20 m/min was reduced at the 14th, 21st and 28th min compared to the sedentary group, as well at 25 m/min at the 21st and 28th min. Plasma glucose during the incremental speed test was decreased in the exercised group at the moment of exhaustion (48th min compared to the sedentary group (27th min. Endurance training positively modulates the mitochondrial activity and capacity of substrate oxidation in muscle and liver. Thus, in contrast to other studies on high load of exercise, the effects of endurance training on the decrease of plasma glucose during constant and incremental speed tests was significantly higher in exercised than in sedentary rats and associated with improved muscle and hepatic oxidative capacity, constituting an important non-pharmacological intervention tool for the prevention of insulin resistance, including type 2 diabetes mellitus.

  16. Heart Rate Variability: Effect of Exercise Intensity on Postexercise Response

    Science.gov (United States)

    James, David V. B.; Munson, Steven C.; Maldonado-Martin, Sara; De Ste Croix, Mark B. A.

    2012-01-01

    The purpose of the present study was to investigate the influence of two exercise intensities (moderate and severe) on heart rate variability (HRV) response in 16 runners 1 hr prior to (-1 hr) and at +1 hr, +24 hr, +48 hr, and +72 hr following each exercise session. Time domain indexes and a high frequency component showed a significant decrease…

  17. High Intensity Interval Training Leads to Greater Improvements in Acute Heart Rate Recovery and Anaerobic Power as High Volume Low Intensity Training

    Science.gov (United States)

    Stöggl, Thomas L.; Björklund, Glenn

    2017-01-01

    The purpose of the current study was to explore if training regimes utilizing diverse training intensity distributions result in different responses on neuromuscular status, anaerobic capacity/power and acute heart rate recovery (HRR) in well-trained endurance athletes. Methods: Thirty-six male (n = 33) and female (n = 3) runners, cyclists, triathletes and cross-country skiers [peak oxygen uptake: (VO2peak): 61.9 ± 8.0 mL·kg−1·min−1] were randomly assigned to one of three groups (blocked high intensity interval training HIIT; polarized training POL; high volume low intensity oriented control group CG/HVLIT applying no HIIT). A maximal anaerobic running/cycling test (MART/MACT) was performed prior to and following a 9-week training period. Results: Only the HIIT group achieved improvements in peak power/velocity (+6.4%, P 0.05). Acute HRR was improved in HIIT (11.2%, P = 0.002) and POL (7.9%, P = 0.023) with no change in the HVLIT oriented control group. Conclusion: Only a training regime that includes a significant amount of HIIT improves the neuromuscular status, anaerobic power and the acute HRR in well-trained endurance athletes. A training regime that followed more a low and moderate intensity oriented model (CG/HVLIT) had no effect on any performance or HRR outcomes. PMID:28824457

  18. High-intensity exercise and recovery during short-term ...

    African Journals Online (AJOL)

    to power athletes and other individuals wishing to improve performance in ... effect of creatine supplementation on physical performance. It has been reported that ... high-intensity work performance.1,2,5,16,31,36 Such activities as resistance ...

  19. High-spin levels in 39K excited by the 41Ca(d,α) reaction

    International Nuclear Information System (INIS)

    Sugarbaker, E.; Boyd, R.N.; Cline, D.; Vold, P.B.; Lien, J.R.; Goode, P.R.

    1979-01-01

    The 41 Ca(d,α) 39 K reaction has been used to investigate the low-lying high-spin states in 39 K. Conflicting spin assignments for the 5.719 MeV level in 39 K of 9/2 - of 13/2 - have been suggested in earlier studies. A 1p-2h model reproduces both the 41 Ca(d,α) 39 K and 39 K(α,α') 39 K reaction data leading to the high-spin states if the 5.719 MeV level is assumed to have a J/sup π/ of 13/2 - . An alternate assignment of J/sup π/ = 9/2 - for this level is shown to produce very poor agreement with the model predictions

  20. Exercise intensity of cycle-touring events.

    Science.gov (United States)

    Neumayr, G; Pfister, R; Mitterbauer, G; Gaenzer, H; Sturm, W; Eibl, G; Hoertnagl, H

    2002-10-01

    The aim of the study was to analyze the exercise intensity of recreational cyclists participating in a cycling-touring event. In 14 male healthy recreational cyclists heart rate (HR) monitoring was performed during the Otztal Radmarathon 1999 (distance: 230 km; altitude difference: 5500 m) in order to evaluate the HR response and to estimate the cardiopulmonary strains for the less-trained athlete confronted with such a marathon. Four different exercise intensities were defined as percentages of maximal HR (HR(max)) as follows: recovery HR (HR(re)) 90 %. All athletes finished the competition successfully. The mean racing time was 10 h 14 min, the average speed 22.5 km/h. The mean HR(max) was 188 bpm, the average value of the measured HRs (HR(average)) was 145 bpm resulting in a mean HR(average)/HR(max) ratio of 0.77. Athletes spent 18.5 % (1 h 54 min) of total race time within HR(re), 28 % (2 h 52 min) within HR(ma), 39.5 % (4 h 02 min) within HR(ia), and 14 % (1 h 26 min) within HR(an). The vast majority of exercise was done under "aerobic conditions" (HR(re) + HR(ma) + HR(ia) = 86 % or 8 h 48 min) - confirming the knowledge that the aerobic energy supply is crucial for the performance of long-term exercise. The large amount of high exercise intensities (HR(ia) + HR(an) = 53.5 % or 5 h 30 min), however, features the intense cardiopulmonary strains evoked by such competitions. The HR response was related to the course profile with HRs significantly declining in all subjects to an extent of 10 % during the course of race. Our findings show that the exercise intensity borne by recreational cyclists during a cycle-touring event is high and very similar to that of professionals. With respect to the high cardiovascular strains a thorough medical screening is advisable for any participant of such an event combining both high volume and high intensity loads.

  1. A high-fat meal promotes lipid-load and apolipoprotein B-48 receptor transcriptional activity in circulating monocytes.

    Science.gov (United States)

    Varela, Lourdes M; Ortega, Almudena; Bermudez, Beatriz; Lopez, Sergio; Pacheco, Yolanda M; Villar, Jose; Abia, Rocio; Muriana, Francisco J G

    2011-05-01

    The postprandial metabolism of dietary fats results in the production of apolipoprotein B-48 (apoB48)-containing triglyceride-rich lipoproteins (TRLs), which cause rapid receptor-mediated macrophage lipid engorgement via the apoB48 cell surface receptor (apoB48R). Monocytes circulate together with apoB48-containing TRLs in the postprandial bloodstream and may start accumulating lipids even before their migration to tissues and differentiation to macrophages. We sought to determine whether circulating monocytes are equipped with apoB48R and whether, in the postprandial state, circulating monocytes accumulate lipids and modulate apoB48R transcriptional activity after intake of a high-fat meal. In a crossover design, we studied the effect of a high-fat meal on fasting and postprandial concentrations of triglycerides, free fatty acids, cholesterol, and insulin in 12 healthy men. TRLs and monocytes were freshly isolated at fasting, hourly until the postprandial peak, and at the late postprandial phase. TRLs were subjected to triglycerides, apoB48, and apolipoprotein B-100 analyses; and lipid accumulation and apoB48R mRNA expression levels were measured in monocytes. Monocytes showed a time-dependent lipid accumulation in response to the high-fat meal, which was paralleled by an increase in apoB48R mRNA expression levels. These effects were coincident only with an increase in apoB48-containing TRLs in the postprandial phase and were also observed ex vivo in freshly isolated monocytes incubated with apoB48-containing TRLs. In a setting of abundant plasma apoB48-containing TRLs, these findings highlight the role of dietary fat in inducing lipid accumulation and apoB48R gene transcription in circulating monocytes.

  2. Piezoelectrically-induced stress-luminescence phenomenon in CaAl2O4:Eu2+

    International Nuclear Information System (INIS)

    Wei, Yongbin; Wu, Zheng; Jia, Yanmin; Liu, Yongsheng

    2015-01-01

    Piezoelectrically-induced stress-luminescence in the CaAl 2 O 4 :Eu 2+ was investigated. Blue light that was visible to the naked eye could be observed in the dark when a pulse force of ∼7.7 kN was applied to the sample. The intensity of the stress-luminescence strongly depended on the magnitude of the applied force during a pulse cycle. The intensity decreased with repetitive application of pulse stress and was completely recovered after irradiation with ultraviolet light. It is suggested that the stress-luminescence effect in CaAl 2 O 4 :Eu 2+ arises from the piezoelectrically-induced de-trapping of the charge carriers. A CaAl 2 O 4 :Eu 2+ ceramic that exhibits a stress-luminescence effect has potential applications in smart stress optically-sensing devices. - Highlights: • The strong induced stress-luminescence in CaAl 2 O 4 :Eu 2+ was observed. • The stress-luminescent intensity strongly depends on the magnitude of force. • The stress-luminescence could be completely recovered after the UV irradiation. • The strong stress-luminescent effect is potential in stress-light sensors

  3. Vibrational spectroscopic study of poldervaartite CaCa[SiO3(OH)(OH)

    Science.gov (United States)

    Frost, Ray L.; López, Andrés; Scholz, Ricardo; Lima, Rosa Malena Fernandes

    2015-02-01

    We have studied the mineral poldervaartite CaCa[SiO3(OH)(OH)] which forms a series with its manganese analogue olmiite CaMn[SiO3(OH)](OH) using a range of techniques including scanning electron microscopy, thermogravimetric analysis, Raman and infrared spectroscopy. Chemical analysis shows the mineral is reasonably pure and contains only calcium and manganese with low amounts of Al and F. Thermogravimetric analysis proves the mineral decomposes at 485 °C with a mass loss of 7.6% compared with the theoretical mass loss of 7.7%. A strong Raman band at 852 cm-1 is assigned to the SiO stretching vibration of the SiO3(OH) units. Two Raman bands at 914 and 953 cm-1 are attributed to the antisymmetric vibrations. Intense prominent peaks observed at 3487, 3502, 3509, 3521 and 3547 cm-1 are assigned to the OH stretching vibration of the SiO3(OH) units. The observation of multiple OH bands supports the concept of the non-equivalence of the OH units. Vibrational spectroscopy enables a detailed assessment of the molecular structure of poldervaartite.

  4. High-intensity exercise and recovery during short-term ...

    African Journals Online (AJOL)

    Objective. To determine the effect of short-term creatine supplementation plus a protein-carbohydrate formula on high-intensity exercise performance and recovery. Design. A repeated-measures, experimental study, employing a randomised, double-blind, placebo-controlled, group comparison design was used.

  5. Mitochondrial Ca2+ influx and efflux rates in guinea pig cardiac mitochondria: low and high affinity effects of cyclosporine A.

    Science.gov (United States)

    Wei, An-Chi; Liu, Ting; Cortassa, Sonia; Winslow, Raimond L; O'Rourke, Brian

    2011-07-01

    Ca(2+) plays a central role in energy supply and demand matching in cardiomyocytes by transmitting changes in excitation-contraction coupling to mitochondrial oxidative phosphorylation. Matrix Ca(2+) is controlled primarily by the mitochondrial Ca(2+) uniporter and the mitochondrial Na(+)/Ca(2+) exchanger, influencing NADH production through Ca(2+)-sensitive dehydrogenases in the Krebs cycle. In addition to the well-accepted role of the Ca(2+)-triggered mitochondrial permeability transition pore in cell death, it has been proposed that the permeability transition pore might also contribute to physiological mitochondrial Ca(2+) release. Here we selectively measure Ca(2+) influx rate through the mitochondrial Ca(2+) uniporter and Ca(2+) efflux rates through Na(+)-dependent and Na(+)-independent pathways in isolated guinea pig heart mitochondria in the presence or absence of inhibitors of mitochondrial Na(+)/Ca(2+) exchanger (CGP 37157) or the permeability transition pore (cyclosporine A). cyclosporine A suppressed the negative bioenergetic consequences (ΔΨ(m) loss, Ca(2+) release, NADH oxidation, swelling) of high extramitochondrial Ca(2+) additions, allowing mitochondria to tolerate total mitochondrial Ca(2+) loads of >400nmol/mg protein. For Ca(2+) pulses up to 15μM, Na(+)-independent Ca(2+) efflux through the permeability transition pore accounted for ~5% of the total Ca(2+) efflux rate compared to that mediated by the mitochondrial Na(+)/Ca(2+) exchanger (in 5mM Na(+)). Unexpectedly, we also observed that cyclosporine A inhibited mitochondrial Na(+)/Ca(2+) exchanger-mediated Ca(2+) efflux at higher concentrations (IC(50)=2μM) than those required to inhibit the permeability transition pore, with a maximal inhibition of ~40% at 10μM cyclosporine A, while having no effect on the mitochondrial Ca(2+) uniporter. The results suggest a possible alternative mechanism by which cyclosporine A could affect mitochondrial Ca(2+) load in cardiomyocytes, potentially

  6. Compton spectra of atoms at high x-ray intensity

    Science.gov (United States)

    Son, Sang-Kil; Geffert, Otfried; Santra, Robin

    2017-03-01

    Compton scattering is the nonresonant inelastic scattering of an x-ray photon by an electron and has been used to probe the electron momentum distribution in gas-phase and condensed-matter samples. In the low x-ray intensity regime, Compton scattering from atoms dominantly comes from bound electrons in neutral atoms, neglecting contributions from bound electrons in ions and free (ionized) electrons. In contrast, in the high x-ray intensity regime, the sample experiences severe ionization via x-ray multiphoton multiple ionization dynamics. Thus, it becomes necessary to take into account all the contributions to the Compton scattering signal when atoms are exposed to high-intensity x-ray pulses provided by x-ray free-electron lasers (XFELs). In this paper, we investigate the Compton spectra of atoms at high x-ray intensity, using an extension of the integrated x-ray atomic physics toolkit, xatom. As the x-ray fluence increases, there is a significant contribution from ionized electrons to the Compton spectra, which gives rise to strong deviations from the Compton spectra of neutral atoms. The present study provides not only understanding of the fundamental XFEL-matter interaction but also crucial information for single-particle imaging experiments, where Compton scattering is no longer negligible. , which features invited work from the best early-career researchers working within the scope of J. Phys. B. This project is part of the Journal of Physics series’ 50th anniversary celebrations in 2017. Sang-Kil Son was selected by the Editorial Board of J. Phys. B as an Emerging Leader.

  7. Effect of ball-milling to the surface morphology of CaCO3

    Science.gov (United States)

    Sulimai, N. H.; Rani, Rozina Abdul; Khusaimi, Z.; Abdullah, S.; Salifairus, M. J.; Alrokayan, Salman; Khan, Haseeb; Rusop, M.

    2018-05-01

    Calcium Carbonate can be synthesized in many approaches. This work studied on the physical changes to Calcium Carbonate (CaCO3) by ball-milling activity in different parameters; number of ball; collision duration; revolution per minute (RPM). Zirconia balls were used in the work because it has the best durability to withstand ball-milling conditions set. Industrial grade CaCO3 particles that were run in aforementioned parameters were characterized by Field Emission Scanning Electron Microscope (FE-SEM) to study the physical changes on the size and surface of the CaCO3. They were also characterized with Fourier Transform Infra-red Spectroscopy (FTIR) were fingerprint of CaCO3 regions were identified and any changes in the band position and intensity were discussed. Number of Zirconia balls and collision duration is directly proportional to the absorbance intensity whereas it is inversely proportional for the rpm. The best number of parameters producing the highest Absorbance is 100 Zirconia balls in duration of 1 hour and 100rpm.

  8. Diagnostic value of combined determination of serum CEA, CA72-4 and TSGF levels in patients with gastric cancer

    International Nuclear Information System (INIS)

    Wang Yuyi; Gu Yan

    2007-01-01

    Objective: To explore the diagnostic value of combined determination of serum CEA, CA72-4 and TSGF levels for gastric cancer. Methods: Serum CEA, CA72-4(with RIA) and TSGF (with biochemistry)levels were measured in 31 patients with gastric cancer and 35 controls. Results: As a single tumor marker for diagnosis, the sensitivity of CEA, CA72-4 and TSGF was 23. 0%, 38.0%, 48.0% respectively and the specificity was 23.0%, 38.0%, 48.0% respectively with combined detection of the three markers and assuming two or more markers positive as diagnostic, the sensitivity would be 67.0% and specificity would be 88.0%. Conclusion: Combined determination of serum CEA, CA72-4 and TSGF levels could promote the clinical usefulness for diagnosis of gastric cancer. (authors)

  9. Bremsstrahlung production with high-intensity laser matter interactions and applications

    NARCIS (Netherlands)

    Galy, J.; Maucec, M.; Hamilton, D. J.; Edwards, R.; Magill, J.

    2007-01-01

    In the last decade an evolution of experimental relativistic laser-plasma physics has led to highly sophisticated lasers, which are now able to generate ultra short pulses and can be focused to intensities in excess of 10(21) W cm(-2), with more than 500 J on target. In the intense electric field of

  10. PROBABLE IDENTIFICATION OF THE ON-DISK COUNTERPART OF SPICULES IN HINODE Ca II H OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    De Wijn, A. G., E-mail: dwijn@ucar.edu [High Altitude Observatory, National Center for Atmospheric Research, P.O. Box 3000, Boulder, CO 80307 (United States)

    2012-09-20

    I present a study of high-resolution time series of Ca II H images and Fe I 630.15 nm spectra taken with the Solar Optical Telescope on the Hinode spacecraft. There is excellent correspondence between the Ca II H and the Fe I line core intensity, except tenuous emission around the network field concentrations in the former that is absent in the latter. Analysis of on-disk observations and a comparison with limb observations suggests that this 'network haze' corresponds to spicules, and likely to type-II spicules in particular. They are known to appear in emission in on-disk broadband Ca II H diagnostics and the network haze is strongest in those areas where features similar to type-II spicules are produced in simulations.

  11. High-intensity interval training (HIIT for patients with chronic diseases

    Directory of Open Access Journals (Sweden)

    Leanna M. Ross

    2016-06-01

    Full Text Available Exercise training provides physiological benefits for both improving athletic performance and maintaining good health. Different exercise training modalities and strategies exist. Two common exercise strategies are high-intensity interval training (HIIT and moderate-intensity continuous exercise training (MCT. HIIT was first used early in the 20th century and popularized later that century for improving performance of Olympic athletes. The primary premise underlying HIIT is that, compared to energy expenditure-matched MCT, a greater amount of work is performed at a higher intensity during a single exercise session which is achieved by alternating high-intensity exercise intervals with low-intensity exercise or rest intervals. Emerging research suggests that this same training method can provide beneficial effects for patients with a chronic disease and should be included in the comprehensive medical management plan. Accordingly, a major consideration in developing an individual exercise prescription for a patient with a chronic disease is the selection of an appropriate exercise strategy. In order to maximize exercise training benefits, this strategy should be tailored to the individual's need. The focus of this paper is to provide a brief summary of the current literature regarding the use of HIIT to enhance the functional capacity of individuals with cardiovascular, pulmonary, and diabetes diseases.

  12. Estimation of ultraviolet radiation dose using CaF2:Tb phosphor

    International Nuclear Information System (INIS)

    Fukuda, Y.; Ohtaki, H.; Owaki, S.

    1996-01-01

    To observe and estimate the dose of ultraviolet (UV) radiation in sunlight, the available thermoluminescence (TL) materials were studied. Several kinds of lanthanide elements were doped in pure CaF 2 powdered crystal and the properties of the Tl for UV were observed. The TL intensity from CaF 2 :Tb was the highest among the samples doped with various lanthanide elements, and form the TL emission spectra (380-540 nm) the TL is estimated to be due to inner transition of Tb 3+ . The peak wavelength of the TL excitation light was located approximately at 235 nm and light of a longer wavelength than 320 nm was unable to excite the TL. The ultraviolet response of CaF 2 :Tb depended on its sintering temperature. Even without γ ray pre-irradiation the CaF 2 :Tb sample with 1 h exposure to sunlight has enough sensitivity to estimate the change of UV. Seasonal change of UV intensity in sunlight was measured with this TLD during four months in 1993. The results agreed with that of other institutes in Japan. (author)

  13. Relative Match Intensities at High Altitude in Highly-Trained Young Soccer Players (ISA3600).

    Science.gov (United States)

    Buchheit, Martin; Hammond, Kristal; Bourdon, Pitre C; Simpson, Ben M; Garvican-Lewis, Laura A; Schmidt, Walter F; Gore, Christopher J; Aughey, Robert J

    2015-03-01

    To compare relative match intensities of sea-level versus high-altitude native soccer players during a 2-week camp at 3600 m, data from 7 sea-level (Australian U17 National team, AUS) and 6 high-altitude (a Bolivian U18 team, BOL) native soccer players were analysed. Two matches were played at sea-level and three at 3600 m on Days 1, 6 and 13. The Yo-Yo Intermittent recovery test (vYo-YoIR1) was performed at sea-level, and on Days 3 and 10. Match activity profiles were measured via 10-Hz GPS. Distance covered >14.4 km.h(-1) (D>14.4 km·h(-1)) and >80% of vYo-YoIR1 (D>80%vYo-YoIR1) were examined. Upon arrival at altitude, there was a greater decrement in vYo-YoIR1 (Cohen's d +1.0, 90%CL ± 0.8) and D>14.4 km·h(-1) (+0.5 ± 0.8) in AUS. D>14.4 km.h(-1) was similarly reduced relative to vYo-YoIR1 in both groups, so that D>80%vYo-YoIR1 remained similarly unchanged (-0.1 ± 0.8). Throughout the altitude sojourn, vYo-YoIR1 and D>14.4 km·h(-1) increased in parallel in AUS, so that D>80%vYo-YoIR1 remained stable in AUS (+6.0%/match, 90%CL ± 6.7); conversely D>80%vYo-YoIR1 decreased largely in BOL (-12.2%/match ± 6.2). In sea-level natives competing at high-altitude, changes in match running performance likely follow those in high-intensity running performance. Bolivian data confirm that increases in 'fitness' do not necessarily translate into greater match running performance, but rather in reduced relative exercise intensity. Key pointsWhen playing at high-altitude, players may alter their activities during matches in relation to their transient maximal physical capacities, possibly to maintain a 'tolerable' relative exercise intensity.While there is no doubt that running performance per se in not the main determinant of match outcomes (Carling, 2013), fitness levels influence relative match intensity (Buchheit et al., 2012, Mendez-Villanueva et al., 2013), which in-turn may impact on decision making and skill performance (Rampinini et al., 2008).In the context of

  14. Tune measurements with high intensity ion beams at GSI SIS-18

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Rahul [GSI, Darmstadt (Germany); TEMF, TU Darmstadt (Germany); Forck, Peter; Kowina, Piotr; Kaufmann, Wolfgang [GSI, Darmstadt (Germany); Weiland, Thomas [TEMF, TU Darmstadt (Germany)

    2012-07-01

    A precise tune measurement during a full accelerating cycle is required to achieve stable high current operation. A new system has been commissioned at GSI for position, orbit and tune measurements. It consists of three distinct parts; an exciter which provides power to excite coherent betatron oscillations in the bunched beam; Fast ADCs to digitize the BPM signals at 125 MSa/s; the post processing electronics uses digitized BPM signals to acquire one position value per bunch. Subsequently the baseband tune is determined by Fourier transformation of the position data. Experiments were conducted to understand the effects of high beam intensity on tune at injection plateau (11.4 MeV/u) and during acceleration ramp (11.4-600 MeV/u). These experiments were performed with U{sup 73+} and Ar{sup 18+} ion beam at highest achievable intensities of 2.10{sup 9} and 2.5.10{sup 10} respectively. Tune shift with increased intensity was observed. The working principle of the tune measurement system and observed high intensity effects on tune will be reported in this contribution.

  15. Volumetric intensity dependence on the formation of molecular and atomic ions within a high intensity laser focus.

    Science.gov (United States)

    Robson, Lynne; Ledingham, Kenneth W D; McKenna, Paul; McCanny, Thomas; Shimizu, Seiji; Yang, Jiamin M; Wahlström, Claes-Göran; Lopez-Martens, Rodrigo; Varju, Katalin; Johnsson, Per; Mauritsson, Johan

    2005-01-01

    The mechanism of atomic and molecular ionization in intense, ultra-short laser fields is a subject which continues to receive considerable attention. An inherent difficulty with techniques involving the tight focus of a laser beam is the continuous distribution of intensities contained within the focus, which can vary over several orders of magnitude. The present study adopts time of flight mass spectrometry coupled with a high intensity (8 x 10(15) Wcm(-2)), ultra-short (20 fs) pulse laser in order to investigate the ionization and dissociation of the aromatic molecule benzene-d1 (C(6)H(5)D) as a function of intensity within a focused laser beam, by scanning the laser focus in the direction of propagation, while detecting ions produced only in a "thin" slice (400 and 800 microm) of the focus. The resultant TOF mass spectra varies significantly, highlighting the dependence on the range of specific intensities accessed and their volumetric weightings on the ionization/dissociation pathways accessed.

  16. Drift tube suspension for high intensity linear accelerators

    International Nuclear Information System (INIS)

    Clark, D.C.; Frank, J.A.; Liska, D.J.; Potter, R.C.; Schamaun, R.G.

    1982-01-01

    The disclosure relates to a drift tube suspension for high intensity linear accelerators. The system comprises a series of box-sections girders independently adjustably mounted on a linear accelerator. A plurality of drift tube holding stems are individually adjustably mounted on each girder

  17. Intense neutron source: high-voltage power supply specifications

    International Nuclear Information System (INIS)

    Riedel, A.A.

    1980-08-01

    This report explains the need for and sets forth the electrical, mechanical and safety specifications for a high-voltage power supply to be used with the intense neutron source. It contains sufficient information for a supplier to bid on such a power supply

  18. Drift tube suspension for high intensity linear accelerators

    Science.gov (United States)

    Liska, Donald J.; Schamaun, Roger G.; Clark, Donald C.; Potter, R. Christopher; Frank, Joseph A.

    1982-01-01

    The disclosure relates to a drift tube suspension for high intensity linear accelerators. The system comprises a series of box-sections girders independently adjustably mounted on a linear accelerator. A plurality of drift tube holding stems are individually adjustably mounted on each girder.

  19. Annotated bibliography on high-intensity linear accelerators

    International Nuclear Information System (INIS)

    Jameson, R.A.; Roybal, E.U.

    1978-01-01

    A technical bibliography covering subjects important to the design of high-intensity beam transport systems and linear accelerators is presented. Space charge and emittance growth are stressed. Subject and author concordances provide cross-reference to detailed citations, which include an abstract and notes on the material. The bibliography resides in a computer database that can be searched for key words and phrases

  20. Calcium in pollen-pistil interaction in 'Petunia hybrida Hat'. Pt. 3. Localization of Ca2+ ions and Ca2+-ATPase in pollinated pistil

    International Nuclear Information System (INIS)

    Bednarska, E.; Butowt, R.

    1995-01-01

    Studies were carried out of Ca 2+ and Ca 2+ -ATPase localization in pollinated (6 and 48 h after pollination) pistils of 'Petunia hybrida'. The results were confronted with Ca 2+ localization in mature pollen grain and in unpollinated pistil. It has been found that after pollination the number of Ca 2+ sequestered in the stigmal exudate and in the sporoderm of the pollen grain gets lower. That phenomenon was associated with the appearance of a large number of Sb/Ca precipitates in the submembrane cytoplasm of the germinating pollen. In the vacuolized pollen grain, i.e. grown into a pollen tube, there were only a few precipitates. In the pollen tube, Ca 2+ were found in the organelles of the tip cytoplasm and in the external pectin cell wall. Studies with the use of 45 Ca 2+ have revealed that the source of calcium ions incorporated into the pollen tube tip and its pectin wall is the transmitting tract of the style. In the transmitting tract overgrown with pollen tubes, Ca 2+ were localized in the intercellular matrix and in the transmitting cell. Sb/Ca precipitates occurred in the nuclei, around the secretary vesicles and on the plasmalemma in the transverse walls region. Elevated Ca 2+ level was found in degenerating cells (inhibited pollen tubes, transmitting cells, nucellar cells). The progressing degeneration process of the cells of the transmitting tract of the pollinated pistil was associated with a decrease in the activity of plasmalemma Ca 2+ -ATPase. (author). 30 refs, 19 figs

  1. Ultrafast photoionization dynamics at high laser intensities in the xuv regime

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, B.; Vagov, A.; Axt, V. M.; Pietsch, U. [Institut fuer Theoretische Physik III, Universitaet Bayreuth, D-95440 Bayreuth (Germany); Institut fuer Festkoerperphysik, Universitaet Siegen, D-57068 Siegen (Germany)

    2011-10-15

    We study the ionization dynamics in the soft-x-ray regime for high intensities and short pulses for excitations near the ionization threshold. Using a one-dimensional helium atom model, we compare exact numerical solutions with time-dependent Hartree-Fock results in order to identify the role of electron-electron correlations. At moderate intensities but still in the x-ray and short-pulse regime, we find that the Hartree-Fock theory reproduces well the dynamics of the ground-state occupation, while at high intensities strong correlation effects occur for excitations close to the threshold. From their characteristic momentum distributions, we can identify contributions to the double ionization from sequential three-photon and nonsequential or sequential two-photon processes. At elevated intensities these contributions deviate from their usual intensity scaling due to saturation effects, even though the total double-ionization probability stays below 10%. Furthermore, analysis of the time evolution of the momentum distribution reveals signatures of the energy-time uncertainty which indicate a coherent regime of the dynamics.

  2. Experiment for a measurement of the charge radius of the proton at the S-DALINAC and investigation of the fine structure of giant resonances in {sup 28}Si, {sup 48}Ca and {sup 166}Er with the help of the wavelet analysis; Experiment zur Messung des Ladungsradius des Protons am S-DALINAC und Untersuchung der Feinstruktur von Riesenresonanzen in {sup 28}Si, {sup 48}Ca und {sup 166}Er mit Hilfe der Waveletanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Pysmenetska, Inna

    2009-07-22

    The present thesis consists of two parts. In the first part a novel experimental method for the measurement of the proton root-mean-square radius at the S-DALINAC is presented. A setup based on semiconductor detectors is realized. In contrast to previous experiments it allows a simultaneous measurement of the momentum transfer dependence of the elastic electron scattering cross section. A possible suppression of the significant electron and bremsstrahlung background observed in a test experiment was investigated with the help of different methods, such as {delta}E-E telescopes, the time of flight method with a pulsed beam and pulse shape discrimination. The combination of these methods allows a reduction of the background at all scattering angles, which should allow a successful measurement. The response of the detector system was studied with the help of Monte-Carlo simulations with an emphasis on the dependence of the expected accuracy of different parameters. The second part of this work describes an investigation of the fine structure of giant resonances in {sup 28}Si, {sup 48}Ca and {sup 166}Er with the help of a wavelet analysis. The discrete wavelet transform was used for a background determination in spectra of the iso vector E1 and the M2 giant resonances in {sup 48}Ca. This allows the extraction of 1{sup -} und 2{sup -} level densities in the excitation energy region of the respective resonances with the help of a fluctuation analysis. A fluctuation analysis of the fine structure of the isoscalar E2 resonance in {sup 166}Er allows the extraction of the coherent widths of the 2{sup +} states. In the excitation energy region E{sub x}=10-16 MeV widths between 30 and 80 eV are found. The fine structure of the giant resonances is furthermore specified by characteristic scales. In this thesis scales in {sup 28}Si and {sup 48}Ca are extracted with the help of the above mentioned wavelet transform. In {sup 28}Si the isovector E1 and isoscalar E2 resonances were

  3. rf coaxial couplers for high-intensity linear accelerators

    International Nuclear Information System (INIS)

    Manca, J.J.; Knapp, E.A.

    1980-02-01

    Two rf coaxial couplers that are particularly suitable for intertank connection of the disk-and-washer accelerating structure for use in high-intensity linear accelerators have been developed. These devices have very high coupling to the accelerating structure and very low rf power loss at the operating frequency, and they can be designed for any relative particle velocity β > 0.4. Focusing and monitoring devices can be located inside these couplers

  4. CW high intensity non-scaling FFAG proton drivers

    OpenAIRE

    Johnstone, C.; Berz, M.; Makino, K.; Snopok, P.

    2012-01-01

    Accelerators are playing increasingly important roles in basic science, technology, and medicine including nuclear power, industrial irradiation, material science, and neutrino production. Proton and light-ion accelerators in particular have many research, energy and medical applications, providing one of the most effective treatments for many types of cancer. Ultra high-intensity and high-energy (GeV) proton drivers are a critical technology for accelerator-driven sub-critical reactors (ADS)...

  5. Approach to a very high intensity beam at J-PARC

    International Nuclear Information System (INIS)

    Yamazaki, Y.

    2007-01-01

    The high-intensity, high-energy proton accelerator project, J-PARC, comprises the 400-MeV proton linac, the 3-GeV, 1-MW Rapid-Cycling Synchrotron (RCS) and the 50-GeV Marin Ring (MR) Synchrotron. The secondary particles such as neutrons, muons, Kaons, neutrinos and so forth will be fully made use of for materials science, life science, nuclear physics, and particle physics. Even the industrial use of the neutrons and the nuclear energy application are incorporated in the project. The rationale for choosing the accelerator schemes are presented together with the present status of the project and research and development for the high-intensity, high-energy proton accelerators J-PARC. The development of the high-field gradient RF cavity system making use of the magnetic alloy (MA), which is really necessary for the future development of the high-power proton accelerators, is reported in detail. (author)

  6. Synthesis of fermium and transfermium elements using calcium-48 beam

    International Nuclear Information System (INIS)

    Gupta, R.K.; Sandulescu, A.; Greiner, W.

    1977-06-01

    The fragmentation theory is used to suggest the possible targets to be used with the 48 Ca ion beam produced recently at the JINR U-30O heavy-ion cyclotron. Calculations are made for 100 252 102. (author)

  7. Normal coordinate treatment and Raman intensity analysis of yttrium vanadate and calcium tungstate crystal

    Energy Technology Data Exchange (ETDEWEB)

    Budha Addepalli, V; Kumar, S P; Padma, V A; Rajeswara Rao, N [Osmania Univ., Hyderabad (India). Dept. of Physics

    1976-09-01

    Raman scattering tensors of crystalline YVO/sub 4/ and CaWO/sub 4/ are derived. Using the spectra of YVO/sub 4/, the intensities are substituted in the formulae. They are used to determine the polarizability derivatives of V-O bond. Substituting them back into the intensity formulae, a number of equations involving the L elements are obtained. Supplementing them with the matrix equation LL' = G, and using L'FL = ..gamma.., a-l the F-elements are determined. It is observed that the force constants relating to the translations of the group YVO/sub 4/ are quite high, explaining the high melting point of the crystal.

  8. The high intensity solar cell - Key to low cost photovoltaic power

    Science.gov (United States)

    Sater, B. L.; Goradia, C.

    1975-01-01

    This paper discusses the problems associated with conventional solar cells at high intensities and presents the design considerations and performance characteristics of the 'high intensity' (HI) solar cell which appears to eliminate the major problems. Test data obtained at greater than 250 AM1 suns gave a peak output power density of 2 W per sq cm at an efficiency exceeding 6% with an unoptimized cell operating at over 100 C. It appears that operation at 1000 AM1 suns at efficiencies greater than 10% is possible. At 1000 AM1 suns and 10% efficiency, the HI cell manufacturing cost is estimated to be $0.25/watt, with multi-megawatt annual production capability already existing within the industrial sector. A high intensity solar system was also analyzed to determine its cost effectiveness and to assess the benefits of further improving HI cell efficiency.

  9. CHEMICAL ABUNDANCE EVIDENCE OF ENDURING HIGH STAR FORMATION RATES IN AN EARLY-TYPE GALAXY: HIGH [Ca/Fe] IN NGC 5128 GLOBULAR CLUSTERS

    International Nuclear Information System (INIS)

    Colucci, Janet E.; Durán, María Fernanda; Bernstein, Rebecca A.; McWilliam, Andrew

    2013-01-01

    We present [Fe/H], ages, and Ca abundances for an initial sample of 10 globular clusters in NGC 5128 obtained from high-resolution, high signal-to-noise ratio echelle spectra of their integrated light. All abundances and ages are obtained using our original technique for high-resolution integrated light abundance analysis of globular clusters. The clusters have a range in [Fe/H] between –1.6 and –0.2. In this sample, the average [Ca/Fe] for clusters with [Fe/H] <–0.4 is +0.37 ± 0.07, while the average [Ca/Fe] in our Milky Way (MW) and M31 GC samples is +0.29 ± 0.09 and +0.24 ± 0.10, respectively. This may imply a more rapid chemical enrichment history for NGC 5128 than for either the MW or M31. This sample provides the first quantitative picture of the chemical history of NGC 5128 that is directly comparable to what is available for the MW. Data presented here were obtained with the MIKE echelle spectrograph on the Magellan Clay Telescope

  10. CHEMICAL ABUNDANCE EVIDENCE OF ENDURING HIGH STAR FORMATION RATES IN AN EARLY-TYPE GALAXY: HIGH [Ca/Fe] IN NGC 5128 GLOBULAR CLUSTERS

    Energy Technology Data Exchange (ETDEWEB)

    Colucci, Janet E.; Duran, Maria Fernanda; Bernstein, Rebecca A. [Department of Astronomy and Astrophysics, 1156 High Street, UCO/Lick Observatory, University of California, Santa Cruz, CA 95064 (United States); McWilliam, Andrew, E-mail: jcolucci@ucolick.org [Observatories of the Carnegie Institute of Washington, 813 Santa Barbara Street, Pasadena, CA 91101-1292 (United States)

    2013-08-20

    We present [Fe/H], ages, and Ca abundances for an initial sample of 10 globular clusters in NGC 5128 obtained from high-resolution, high signal-to-noise ratio echelle spectra of their integrated light. All abundances and ages are obtained using our original technique for high-resolution integrated light abundance analysis of globular clusters. The clusters have a range in [Fe/H] between -1.6 and -0.2. In this sample, the average [Ca/Fe] for clusters with [Fe/H] <-0.4 is +0.37 {+-} 0.07, while the average [Ca/Fe] in our Milky Way (MW) and M31 GC samples is +0.29 {+-} 0.09 and +0.24 {+-} 0.10, respectively. This may imply a more rapid chemical enrichment history for NGC 5128 than for either the MW or M31. This sample provides the first quantitative picture of the chemical history of NGC 5128 that is directly comparable to what is available for the MW. Data presented here were obtained with the MIKE echelle spectrograph on the Magellan Clay Telescope.

  11. High-efficiency transmision neutron polarizer for high-resolution double crystal diffractometer

    International Nuclear Information System (INIS)

    Ioffe, A.; Krist, T.; Mezei, F.; Gordeev, G.; Ibrayev, B.

    1997-01-01

    An efficient transmission geometry neutron polarizer for the high-resolution double crystal diffractometer at HMI (λ=4.8 A) is described. A polarization of about 94% was achieved and the polarized neutron beam intensity amounts to 40% of the nonpolarized beam intensity. This opens up wide possibilities for the study of magnetic small-angle scattering for extremely small momentum transfer (Q∝10 -5 A -1 ). (orig.)

  12. The Effect of Increasing Sn Content on High-Temperature Mechanical Deformation of an Mg-3%Cu-1%Ca Alloy

    Directory of Open Access Journals (Sweden)

    Georgios S.E. Antipas

    2013-11-01

    Full Text Available Chill casting of magnesium alloy samples with secondary alloying elements of Cu, Ca and Sn at % w.t. concentrations in the range 1–5, 0.1–5 and 0.1–3 respectively, gave rise to appreciably enhanced resistance to high-temperature creep, while maintaining good heat conductivity. The latter was considered to be driven by Cu and Mg-Cu intermetallics while it was clear that Sn mediated the high-temperature performance, mainly via networks of Mg2Sn and MgCaSn precipitates along the Mg matrix grain boundaries. It was postulated that Sn formed intermetallics by preferential substitution of Ca atoms and, thus, did not degrade the heat conductivity by retaining Cu. The % w.t. stoichiometry with the optimum combination of heat conductivity and resistance to high-temperature creep was found to be Mg-3Cu-1Ca-0.1Sn.

  13. High- and moderate-intensity aerobic exercise and excess post-exercise oxygen consumption in men with metabolic syndrome.

    Science.gov (United States)

    Larsen, I; Welde, B; Martins, C; Tjønna, A E

    2014-06-01

    Physical activity is central in prevention and treatment of metabolic syndrome. High-intensity aerobic exercise can induce larger energy expenditure per unit of time compared with moderate-intensity exercise. Furthermore, it may induce larger energy expenditure at post-exercise recovery. The aim of this study is to compare the excess post-exercise oxygen consumption (EPOC) in three different aerobic exercise sessions in men with metabolic syndrome. Seven men (age: 56.7 ± 10.8) with metabolic syndrome participated in this crossover study. The sessions consisted of one aerobic interval (1-AIT), four aerobic intervals (4-AIT), and 47-min continuous moderate exercise (CME) on separate days, with at least 48 h between each test day. Resting metabolic rate (RMR) was measured pre-exercise and used as baseline value. EPOC was measured until baseline metabolic rate was re-established. An increase in O2 uptake lasting for 70.4 ± 24.8 min (4-AIT), 35.9 ± 17.3 min (1-AIT), and 45.6 ± 17.3 min (CME) was observed. EPOC were 2.9 ± 1.7 L O2 (4-AIT), 1.3 ±  .1 L O2 (1-AIT), and 1.4 ± 1.1 L O2 (CME). There were significant differences (P exercise intensity has a significant positive effect on EPOC in men with metabolic syndrome. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Effects of music and video on perceived exertion during high-intensity exercise

    Institute of Scientific and Technical Information of China (English)

    Enoch C.Chow; Jennifer L.Etnier

    2017-01-01

    Background:Dissociative attentional stimuli (e.g.,music,video) are effective in decreasing ratings of perceived exertion (RPE) during low-to-moderate intensity exercise,but have inconsistent results during exercise at higher intensity.The purpose of this study was to assess attentional focus and RPE during high-intensity exercise as a function of being exposed to music,video,both (music and video),or a no-treatment control condition.Methods:During the first session,healthy men (n =15) completed a maximal fitness test to determine the workload necessary for high-intensity exercise (operationalized as 125% ventilatory threshold) to be performed during subsequent sessions.On 4 subsequent days,they completed 20 min of high-intensity exercise in a no-treatment control condition or while listening to music,watching a video,or both.Attentional focus,RPE,heart rate,and distance covered were measured every 4 min during the exercise.Results:Music and video in combination resulted in significantly lower RPE across time (partial η2 =0.36) and the size of the effect increased over time (partial η2 =0.14).Additionally,music and video in combination resulted in a significantly more dissociative focus than the other conditions (partial η2 =0.29).Conclusion:Music and video in combination may result in lower perceived exertion during high-intensity exercise when compared to music or video in isolation.Future research will be necessary to test if reductions in perceived exertion in response to dissociative attentional stimuli have implications for exercise adherence.

  15. Creatine kinase response to high-intensity aerobic exercise in adult-onset muscular dystrophy

    DEFF Research Database (Denmark)

    Andersen, Søren P; Sveen, Marie-Louise; Hansen, Regitze S

    2013-01-01

    We investigated the effect of high-intensity exercise on plasma creatine kinase (CK) in patients with muscular dystrophies.......We investigated the effect of high-intensity exercise on plasma creatine kinase (CK) in patients with muscular dystrophies....

  16. Extremely Elevated CA 125 and CA 19-9 in Endometrioma; A Case Series

    Directory of Open Access Journals (Sweden)

    Vugar Bayramov

    2010-03-01

    Full Text Available Although endometriosis is a benign condition, increased levels of the tumor markers CA 125 and CA 19-9 may be seen. However, these tumor markers reach to very high levels, rarely. In this report, 4 patients between 20 and 43 year-old with extremely elevated CA 125, CA 19-9 and CA 15-3 levels are discussed. In endometriosis extremely increased tumor markers are determined in the case of ruptured endometrioma cyst. There are two mechanisms to clarify extremely elevated levels of CA 125 in endometriosis. First, the peritoneal irritation of CA 125 molecule after the rupture of endometioma cyst and CA 125 secretion from the periton. And the second is penetration of the CA 125 moecule easily to the circulation through the peritoneal endothelial surface after the cyst rupture. In conclusion, the diagnosis of ruptured endometrioma cyst should be kept in mind especially in young patients with extremely elevated serum CA 125 levels with regard to the history and ultrasonographical signs and invasive procedures should be avoided.

  17. CaO-based CO2 sorbents: from fundamentals to the development of new, highly effective materials.

    Science.gov (United States)

    Kierzkowska, Agnieszka M; Pacciani, Roberta; Müller, Christoph R

    2013-07-01

    The enormous anthropogenic emission of the greenhouse gas CO2 is most likely the main reason for climate change. Considering the continuing and indeed growing utilisation of fossil fuels for electricity generation and transportation purposes, development and implementation of processes that avoid the associated emissions of CO2 are urgently needed. CO2 capture and storage, commonly termed CCS, would be a possible mid-term solution to reduce the emissions of CO2 into the atmosphere. However, the costs associated with the currently available CO2 capture technology, that is, amine scrubbing, are prohibitively high, thus making the development of new CO2 sorbents a highly important research challenge. Indeed, CaO, readily obtained through the calcination of naturally occurring limestone, has been proposed as an alternative CO2 sorbent that could substantially reduce the costs of CO2 capture. However, one of the major drawbacks of using CaO derived from natural sources is its rapidly decreasing CO2 uptake capacity with repeated carbonation-calcination reactions. Here, we review the current understanding of fundamental aspects of the cyclic carbonation-calcination reactions of CaO such as its reversibility and kinetics. Subsequently, recent attempts to develop synthetic, CaO-based sorbents that possess high and cyclically stable CO2 uptakes are presented. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Late calcium EDTA rescues hippocampal CA1 neurons from global ischemia-induced death.

    Science.gov (United States)

    Calderone, Agata; Jover, Teresa; Mashiko, Toshihiro; Noh, Kyung-min; Tanaka, Hidenobu; Bennett, Michael V L; Zukin, R Suzanne

    2004-11-03

    Transient global ischemia induces a delayed rise in intracellular Zn2+, which may be mediated via glutamate receptor 2 (GluR2)-lacking AMPA receptors (AMPARs), and selective, delayed death of hippocampal CA1 neurons. The molecular mechanisms underlying Zn2+ toxicity in vivo are not well delineated. Here we show the striking finding that intraventricular injection of the high-affinity Zn2+ chelator calcium EDTA (CaEDTA) at 30 min before ischemia (early CaEDTA) or at 48-60 hr (late CaEDTA), but not 3-6 hr, after ischemia, afforded robust protection of CA1 neurons in approximately 50% (late CaEDTA) to 75% (early CaEDTA) of animals. We also show that Zn2+ acts via temporally distinct mechanisms to promote neuronal death. Early CaEDTA attenuated ischemia-induced GluR2 mRNA and protein downregulation (and, by inference, formation of Zn2+-permeable AMPARs), the delayed rise in Zn2+, and neuronal death. These findings suggest that Zn2+ acts at step(s) upstream from GluR2 gene downregulation and implicate Zn2+ in transcriptional regulation and/or GluR2 mRNA stability. Early CaEDTA also blocked mitochondrial release of cytochrome c and Smac/DIABLO (second mitochondria-derived activator of caspases/direct inhibitor of apoptosis protein-binding protein with low pI), caspase-3 activity (but not procaspase-3 cleavage), p75NTR induction, and DNA fragmentation. These findings indicate that CaEDTA preserves the functional integrity of the mitochondrial outer membrane and arrests the caspase death cascade. Late injection of CaEDTA at a time when GluR2 is downregulated and caspase is activated inhibited the delayed rise in Zn2+, p75NTR induction, DNA fragmentation, and cell death. The finding of neuroprotection by late CaEDTA administration has striking implications for intervention in the delayed neuronal death associated with global ischemia.

  19. Influence of dietary calcium (Ca) and phosphorus (P) on phosphorus retention in chickens

    International Nuclear Information System (INIS)

    Scheideler, S.E.; Sell, J.L.

    1986-01-01

    Experiment 1 was a 3 x 3 factorial arrangement with 3 levels of dietary Ca (3.0, 3.5, and 4.0%) and 3 P feeding programs fed to laying hens for 336 days. The P programs tested were: .64% P fed continuously for 48 weeks; .64, .54, and .44% P; and .56, .49, and .39% P fed when hens were 24 to 36, 36 to 52, and 52 to 72 weeks of age, respectively. In addition to production traits, measurements of P retention were made at 34, 42, 50, 62, and 72 weeks of age. None of the production traits measured showed any dietary effects. Dietary Ca affected P retention at 50, 62, and 72 weeks of age. None of the production traits measured showed any dietary effects. Dietary Ca affected P retention at 50, 62, and 72 weeks of age. Average P retention for the experiment was 104, 148, and 178 mg/day in hens fed 3.0, 3.5, and 4.0% Ca. Dietary P affected P retention at 42 and 72 weeks, with P retention being greater in hens fed .64% P. Ca x P interactions were measured at 42, 62, and 72 weeks of age. Experiment 2 involved 2 levels of dietary Ca (.8 and 1.2%) fed to one-week-old broiler chicks for 8 days during which time 50 uCi 33 P/chick were administered. Serum, femurs, and excreta were collected 48 hours following 33 P dosing. Serum inorganic P and excreted 33 P activity were greater in chicks fed .8% Ca; whereas femur 33 P activity was greater when chicks received the 1.2% Ca diet. These data indicate increased P retention and greater bone deposition of P in chicks fed 1.2% dietary Ca. These results support those of Experiment 1 in which P retention of hens increased as dietary Ca increased

  20. The high intensity approximation applied to multiphoton ionization

    International Nuclear Information System (INIS)

    Brandi, H.S.; Davidovich, L.; Zagury, N.

    1980-08-01

    It is shown that the most commonly used high intensity approximations as applied to ionization by strong electromagnetic fields are related. The applicability of the steepest descent method in these approximations, and the relation between them and first-order perturbation theory, are also discussed. (Author) [pt

  1. Mechanoluminescence by impulsive deformation of γ-irradiated Er-doped CaF2 crystals

    International Nuclear Information System (INIS)

    Brahme, Nameeta; Shukla, Manju; Bisen, D.P.; Kurrey, U.; Choubey, Anil; Kher, R.S.; Singh, Manisha

    2011-01-01

    An impulsive technique has been used for mechanoluminescence (ML) measurements in γ-irradiated Er doped CaF 2 crystals. When the ML is excited impulsively by the impact of moving piston on to γ-irradiated CaF 2 :Er crystals, two peaks are observed in ML intensity with time and it is seen that the peak intensities of first and second peaks (I m1 and I m2 ) increase with increasing impact velocity. However the time corresponding to first and second peaks (t m1 and t m2 ) shifts towards shorter time values with increasing impact velocity. It is also seen that the total ML intensity I Total initially increases with the impact velocity and then it attains a saturation value for higher values of the impact velocity. We have presented a theoretical explanation for the observed results. - Research highlights: → Impulsive technique has been used for mechanoluminescence (ML) studies in γ-irradiated Er doped CaF 2 crystals. → ML intensity exhibited two peaks with time (I m1 and I m2 ), where the intensity of both the peaks increased with increasing impact velocity. → The time of occurrence of the peaks (t m1 and t m2 ) reduced with increasing the impact velocity. → Total ML intensity (I Total ) first increases and then attains a saturation value with an increment in the impact velocity. → A theoretical explanation is presented to the observed results.

  2. A high-intensity He-jet production source for radioactive beams

    International Nuclear Information System (INIS)

    Vieira, D.J.; Kimberly, H.J.; Grisham, D.L.; Talbert, W.L.; Wouters, J.M.; Rosenauer, D.; Bai, Y.

    1993-01-01

    The use of a thin-target, He-jet transport system operating with high primary beam intensities is explored as a high-intensity production source for radioactive beams. This method is expected to work well for short-lived, non-volatile species. As such the thin-target, He-jet approach represents a natural complement to the thick-target ISOL method in which such species are not, in general, rapidly released. Highlighted here is a thin-target, He-jet system that is being prepared for a 500 + μA, 800-MeV proton demonstration experiment at LAMPF this summer

  3. High-pressure crystal growth and electromagnetic properties of 5d double-perovskite Ca3OsO6

    Science.gov (United States)

    Feng, Hai Luke; Shi, Youguo; Guo, Yanfeng; Li, Jun; Sato, Akira; Sun, Ying; Wang, Xia; Yu, Shan; Sathish, Clastin I.; Yamaura, Kazunari

    2013-05-01

    Single crystals of the osmium-containing compound Ca3OsO6 have been successfully grown under high-pressure conditions, for the first time. The crystal structure of Ca3OsO6 were characterized as an ordered double-perovskite structure of space group P21/n with the Ca and Os atoms being fully ordered at the perovskite B-site. The electromagnetic analysis shows that the crystal exhibits a semiconductor-like behavior below 300 K and undergoes an antiferromagnetic transition at 50 K.

  4. Clinical evaluation of CEA, CA19-9, CA72-4 and CA125 in gastric cancer patients with neoadjuvant chemotherapy.

    Science.gov (United States)

    Sun, Zhipeng; Zhang, Nengwei

    2014-12-29

    a positive prediction value for pathologic response to neoadjuvant chemotherapy according to the ROC curve (AUC: 0.764, 95% CI: 0.584 to 0.945, P = 0.020). Our results suggest that high preoperative serum levels of CA72-4 and CA19-9 are associated with higher risk of death, high pretreatment CEA levels (>50 ng/ml) may predict clinical disease progression after neoadjuvant chemotherapy, and a decrease (>70%) of CA72-4 may predict pathologic response to neoadjuvant chemotherapy.

  5. Thermodynamic modeling of the CaO-SiO2-CaCO3-HCaCO2O closed and open system at 25ºC

    Directory of Open Access Journals (Sweden)

    Martínez-Ramírez, S.

    2003-06-01

    Full Text Available This paper reports on a thermodynamic calculation-based study of the CaO-SiOCaCO2-CaCOCaCO3-HCaCO2O closed system at 25 °C, conducted to determine the range of carbonate ion concentrations at which each phase of the system is stable. Portlandite (CH and the CSH gel were found to be stable for carbonate ion concentrations of less than or equal to 7.62 X 10-3 mM/kg and 1.62 x 10-2 mM/kg, respectively. The CSH gel was found to remain stable in the system at pH values ranging from 10.18 to 10.48. In the CaO-SiO2-H2O open system at 25 °C, likewise studied, with PCO2 held constant at atmospheric values, only hydrated silica (SH and calcite were found to be stable.En este trabajo se estudia el sistema CaO2-CaCO3-H2O, cerrado y a 25 ºC a través de cálculos termodinámicos, y se determina el rango de concentración de ion carbonato en el que son estables cada una de las fases del sistema. Se concluye que la portlandita (CH y el gel CSH son estables para concentraciones de ion carbonato iguales o inferiores a 7,62 X 10-3 niM/kg y 1,62 x 10-2 mM/kg respectivamente. El rango de pH en el que el gel CSH es estable en el sistema es 10,18-10,48. También se estudia el sistema CaO-SiO2-H2O a 25 °C, en sistema abierto a PCO2 constante e igual a la de dicho gas en la atmósfera, encontrando que solo la sílice hidratada (SH y la calcita son estables en dicho sistema.

  6. High Intensity Training (HIT) en High Intensity Interval Training (HIIT) bij patiënten met chronische non-specifieke lage rugpijn: effecten op fysieke parameters en subjectieve pijnbeleving

    OpenAIRE

    Nuyttens, Jelle; Vuylsteke, Michiel

    2016-01-01

    Niet-specifieke chronische lage rugpijn (NSCLRP) zorgt via directe en indirecte kosten voor een enorme economische last in onze huidige maatschappij. Tot op heden wordt een grote variëteit aan trainingsprogramma's aangewend in de behandeling van lage rugpijn, maar er bestaat weinig consensus omtrent de ideale trainingsintensiteit. In deze pilotstudie werd de bruikbaarheid en het effect van de combinatie 'High-Intensity Interval Training (HIIT)' en 'High-Intensity Training (HIT)' op pijn, acti...

  7. Negative beliefs about low back pain are associated with persistent high intensity low back pain.

    Science.gov (United States)

    Ng, Sin Ki; Cicuttini, Flavia M; Wang, Yuanyuan; Wluka, Anita E; Fitzgibbon, Bernadette; Urquhart, Donna M

    2017-08-01

    While previous cross-sectional studies have found that negative beliefs about low back pain are associated with pain intensity, the relationship between back beliefs and persistent low back pain is not well understood. This cohort study aimed to examine the role of back beliefs in persistent low back pain in community-based individuals. A hundred and ninety-two participants from a previous musculoskeletal health study were invited to take part in a two-year follow-up study. Beliefs about back pain were assessed by the Back Beliefs Questionnaire (BBQ) at baseline and low back pain intensity was measured by the Chronic Pain Grade Questionnaire at baseline and follow-up. Of the 150 respondents (78.1%), 16 (10.7%) reported persistent high intensity low back pain, 12 (8.0%) developed high intensity low back pain, in 16 (10.7%) their high intensity low back pain resolved and 106 (70.7%) experienced no high intensity low back pain. While participants were generally positive about low back pain (BBQ mean (SD) = 30.2 (6.4)), those with persistent high intensity pain reported greater negativity (BBQ mean (SD) = 22.6 (4.9)). Negative beliefs about back pain were associated with persistent high intensity low back pain after adjusting for confounders (M (SE) = 23.5 (1.6) vs. >30.1 (1.7), p back beliefs were associated with persistent high intensity low back pain over 2 years in community-based individuals. While further longitudinal studies are required, these findings suggest that targeting beliefs in programs designed to treat and prevent persistent high intensity low back pain may be important.

  8. Trends in nitrogen concentrations and load in 48 minor streams draining intensively farmed Danish catchments, 1990-2014. How can the observed trend be explained?

    Science.gov (United States)

    Windolf, Jørgen; Børgesen, Christen; Blicher-Mathiesen, Gitte; Kronvang, Brian; Larsen, Søren E.; Tornbjerg, Henrik

    2016-04-01

    The total land-based nitrogen load to Danish coastal waters has decreased by 50% since 1990 through a reduction of the outlet of nitrogen from sewage point sources and diffuse sources. On a national scale nitrogen load from diffuse sources, has been reduced by 43% , mainly due to limitation of the amount of N input to different crops, rules for timing and application of manure, mandatory demands for catch crops and restoration of wetlands. The latter increasing the nitrogen retention capacity in surface waters. However, on a local scale huge variations exist in the reduction of the diffuse nitrogen load. Since 1990, an important part of the Danish national monitoring program on the aquatic environment (NOVANA) has been directed at quantifying the nitrogen concentrations and load in 48 minor streams draining small intensively farmed catchments. The 48 catchments have a mean size of 18 km2, farmed area constitutes more than 60% of the catchment area and the catchments have no significant outlets of sewage to the streams. The statistical trend results (based on a seasonal Mann-Kendall) from these 48 streams show a 9-65% reduction in the diffuse nitrogen load (mean: 48%). The large differences in trends in the diffuse N load are related to differences in catchment-specific variables such as nitrogen surpluses, nitrogen leaching from the root zone, hydrogeology and nitrogen retention in ground and surface waters.

  9. Luminescence and electron degradation properties of Bi doped CaO phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Yousif, A. [Department of Physics, University of the Free State, P.O. Box 339, Bloemfontein, ZA 9300 (South Africa); Department of Physics, Faculty of Education, University of Khartoum, P.O. Box 321, 11115 Omdurman (Sudan); Kroon, R.E.; Coetsee, E.; Ntwaeaborwa, O.M. [Department of Physics, University of the Free State, P.O. Box 339, Bloemfontein, ZA 9300 (South Africa); Seed Ahmed, H.A.A. [Department of Physics, University of the Free State, P.O. Box 339, Bloemfontein, ZA 9300 (South Africa); Department of Physics, Faculty of Education, University of Khartoum, P.O. Box 321, 11115 Omdurman (Sudan); Swart, H.C., E-mail: swarthc@ufs.ac.za [Department of Physics, University of the Free State, P.O. Box 339, Bloemfontein, ZA 9300 (South Africa)

    2015-11-30

    Graphical abstract: - Highlights: • Blue emitting Ca{sub 1−x}O:Bi{sub x=0.5%} phosphor powder was successfully prepared. • Strong blue near-UV emission was obtained. • Electron beam induced cathodoluminescence intensity degradation occurred. • XPS was successfully used to explain the degradation process. - Abstract: Ca{sub 1−x}O:Bi{sub x=0.5%} phosphor powder was successfully synthesized by the sol-gel combustion method. The structure, morphology and luminescent properties of the phosphor were characterized by X-ray diffraction, scanning electron microscopy, photoluminescence and cathodoluminescence (CL) spectroscopy. The results showed that the Ca{sub 1−x}O:Bi{sub x=0.5%} consisted of single face-centred cubic crystals and that the phosphor particles were uniformly distributed. When the phosphor was excited by a xenon lamp at 355 nm, or a 325 nm He–Cd laser, or electron beam, it emitted strongly in the blue near-UV range with a wavelength of 395 nm ({sup 3}P{sub 1} → {sup 1}S{sub 0} transition of Bi{sup 3+}). The CL intensity was monitored as a function of the accelerating voltage and also as a function of the beam current. The powder was also subjected to a prolonged electron beam irradiation to study the electron beam induced CL intensity degradation. X-ray photoelectron spectroscopy was used to analyze the Ca{sub 1−x}O:Bi{sub x=0.5%} phosphor sample surface before and after degradation.

  10. Compound effect of CaCO3 and CaSO4·2H2O on the strength of steel slag: cement binding materials

    International Nuclear Information System (INIS)

    Qi, Liqian; Liu, Jiaxiang; Liu, Qian

    2016-01-01

    In this study, we replaced 30% of the cement with steel slag to prepare binding material; additionally, small amounts of CaCO 3 and CaSO 4 ·2H 2 O were added. This was done to study the compound effect of CaCO 3 and CaSO 4 ·2H 2 O on the strength of steel slag-cement binding materials. The hydration degree of the steel slag cementitious material was analyzed by XRD, TG and SEM. The results showed that the optimum proportions of CaCO 3 and CaSO 4 ·2H 2 O were 3% and 2%, respectively. Compared with the steel slag-cement binders without adding CaCO 3 and CaSO 4 ·2H 2 O, the compressive strength increased by 59.9% at 3 days and by 17.8% at 28 days. Acting as the nucleation matrix, CaCO 3 could accelerate the hydration of C 3 S. In addition, CaCO 3 was involved in the hydration reaction, generating a new hydration product, which could stably exist in a slurry. Meanwhile, CaSO 4 ·2H 2 O could increase the number of AFt. The compound effect of CaCO 3 and CaSO 4 ·2H 2 O enhanced the intensity of steel slag-cement binding materials and improved the whole hydration behavior. (author)

  11. Reuse Recycler: High Intensity Proton Stacking at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, P. [Fermilab

    2016-07-17

    After a successful career as an antiproton storage and cooling ring, Recycler has been converted to a high intensity proton stacker for the Main Injector. We discuss the commissioning and operation of the Recycler in this new role, and the progress towards the 700 kW design goal.

  12. Shielding for high energy, high intensity electron accelerator installation

    International Nuclear Information System (INIS)

    Warawas, C.; Chongkum, S.

    1997-03-01

    The utilization of electron accelerators (eBA) is gradually increased in Thailand. For instance, a 30-40 MeV eBA are used for tumor and cancer therapy in the hospitals, and a high current eBA in for gemstone colonization. In the near future, an application of eBA in industries will be grown up in a few directions, e.g., flue gases treatment from the coal fire-power plants, plastic processing, rubber vulcanization and food preservation. It is the major roles of Office of Atomic Energy for Peace (OAEP) to promote the peaceful uses of nuclear energy and to regulate the public safety and protection of the environment. By taking into account of radiation safety aspect, high energy electrons are not only harmful to human bodies, but the radioactive nuclides can be occurred. This report presents a literature review by following the National Committee on Radiation Protection and Measurements (NCRP) report No.31. This reviews for parametric calculation and shielding design of the high energy (up to 100 MeV), high intensity electron accelerator installation

  13. MR imaging of the bone marrow using short TI IR, 1. Normal and pathological intensity distribution of the bone marrow

    Energy Technology Data Exchange (ETDEWEB)

    Ishizaka, Hiroshi; Kurihara, Mikiko; Tomioka, Kuniaki; Kobayashi, Kanako; Sato, Noriko; Nagai, Teruo; Heshiki, Atsuko; Amanuma, Makoto; Mizuno, Hitomi.

    1989-02-01

    Normal vertebral bone marrow intensity distribution and its alteration in various anemias were evaluated on short TI IR sequences. Material consists of 73 individuals, 48 normals and 25 anemic patients excluding neoplastic conditions. All normal and reactive hypercellular bone marrow revealed characteristic intensity distribution; marginal high intensity and central low intensity, corresponding well to normal distribution of red and yellow marrows and their physiological or reactive conversion between red and yellow marrows. Aplastic anemia did not reveal normal intensity distribution, presumably due to autonomous condition.

  14. Atomic motion in a high-intensity standing wave laser field

    International Nuclear Information System (INIS)

    Saez Ramdohr, L.F.

    1987-01-01

    This work discusses the effect of a high-intensity standing wave laser field on the motion of neutral atoms moving with a relatively high velocity. The analysis involves a detailed calculation of the force acting on the atoms and the calculation of the diffusion tensor associated with the fluctuations of the quantum force operator. The high-intensity laser field limit corresponds to a Rabi frequency much greater than the natural rate of the atom. The general results are valid for any atomic velocity. Results are then specialized to the case of slow and fast atoms where the Doppler shift of the laser frequency due to the atomic motion is either smaller or larger than the natural decay rate of the atom. The results obtained for the force and diffusion tensor are applied to a particular ideal experiment that studies the evolution of a fast atomic beam crossing a high-intensity laser beam. The theories developed previously, for a similar laser configuration, discuss only the low atomic velocities case and not the more realistic case of fast atoms. Here, an approximate solution of the equation for the distribution is obtained. Starting from the approximate distribution function, the deflection angle and dispersion angle for the atomic beam with respect to the free motion are calculated

  15. High Intensity Interval Training Leads to Greater Improvements in Acute Heart Rate Recovery and Anaerobic Power as High Volume Low Intensity Training

    Directory of Open Access Journals (Sweden)

    Thomas L. Stöggl

    2017-08-01

    Full Text Available The purpose of the current study was to explore if training regimes utilizing diverse training intensity distributions result in different responses on neuromuscular status, anaerobic capacity/power and acute heart rate recovery (HRR in well-trained endurance athletes.Methods: Thirty-six male (n = 33 and female (n = 3 runners, cyclists, triathletes and cross-country skiers [peak oxygen uptake: (VO2peak: 61.9 ± 8.0 mL·kg−1·min−1] were randomly assigned to one of three groups (blocked high intensity interval training HIIT; polarized training POL; high volume low intensity oriented control group CG/HVLIT applying no HIIT. A maximal anaerobic running/cycling test (MART/MACT was performed prior to and following a 9-week training period.Results: Only the HIIT group achieved improvements in peak power/velocity (+6.4%, P < 0.001 and peak lactate (P = 0.001 during the MART/MACT, while, unexpectedly, in none of the groups the performance at the established lactate concentrations (4, 6, 10 mmol·L−1 was changed (P > 0.05. Acute HRR was improved in HIIT (11.2%, P = 0.002 and POL (7.9%, P = 0.023 with no change in the HVLIT oriented control group.Conclusion: Only a training regime that includes a significant amount of HIIT improves the neuromuscular status, anaerobic power and the acute HRR in well-trained endurance athletes. A training regime that followed more a low and moderate intensity oriented model (CG/HVLIT had no effect on any performance or HRR outcomes.

  16. F-actin-based Ca signaling-a critical comparison with the current concept of Ca signaling.

    Science.gov (United States)

    Lange, Klaus; Gartzke, Joachim

    2006-11-01

    A short comparative survey on the current idea of Ca signaling and the alternative concept of F-actin-based Ca signaling is given. The two hypotheses differ in one central aspect, the mechanism of Ca storage. The current theory rests on the assumption of Ca-accumulating endoplasmic/sarcoplasmic reticulum-derived vesicles equipped with an ATP-dependent Ca pump and IP3- or ryanodine-sensitive channel-receptors for Ca-release. The alternative hypothesis proceeds from the idea of Ca storage at the high-affinity binding sites of actin filaments. Cellular sites of F-actin-based Ca storage are microvilli and the submembrane cytoskeleton. Several specific features of Ca signaling such as store-channel coupling, quantal Ca release, spiking and oscillations, biphasic and "phasic" uptake kinetics, and Ca-induced Ca release (CICR), which are not adequately described by the current concept, are inherent properties of the F-actin system and its dynamic state of treadmilling. Copyright 2006 Wiley-Liss, Inc.

  17. Highly frequent promoter methylation and PIK3CA amplification in non-small cell lung cancer (NSCLC)

    International Nuclear Information System (INIS)

    Ji, Meiju; Guan, Haixia; Gao, Cuixia; Shi, Bingyin; Hou, Peng

    2011-01-01

    Lung cancer is the leading cause of cancer-related death worldwide. Genetic and epigenetic alterations have been identified frequently in lung cancer, such as promoter methylation, gene mutations and genomic amplification. However, the interaction between genetic and epigenetic events and their significance in lung tumorigenesis remains poorly understood. We determined the promoter methylation of 6 genes and PIK3CA amplification using quantitative methylation-specific PCR (Q-MSP) and real-time quantitative PCR, respectively, and explore the association of promoter methylation with PIK3CA amplification in a large cohort of clinically well-characterized non-small cell lung cancer (NSCLC). Highly frequent promoter methylation was observed in NSCLC. With 100% diagnostic specificity, excellent sensitivity, ranging from 45.8 to 84.1%, was found for each of the 6 genes. The promoter methylation was associated with histologic type. Methylation of CALCA, CDH1, DAPK1, and EVX2 was more common in squamous cell carcinomas (SCC) compared to adenocarcinomas (ADC). Conversely, there was a trend toward a higher frequency of RASSF1A methylation in ADC than SCC. In addition, PIK3CA amplification was frequently found in NSCLC, and was associated with certain clinicopathologic features, such as smoking history, histologic type and pleural indentation. Importantly, aberrant promoter methylation of certain genes was significantly associated with PIK3CA amplification. Our data showed highly frequent promoter methylation and PIK3CA amplification in Chinese NSCLC population, and first demonstrated the associations of gene methylation with PIK3CA amplification, suggesting that these epigenetic events may be a consequence of overactivation of PI3K/Akt pathway

  18. Dose profile for electron beams obtained with CaSO{sub 4}:Ce,Eu thermoluminescent dosimeters; Perfil de dose de feixes de eletrons obtidos com dosimetros termoluminescentes de CaSO{sub 4}:Ce,Eu

    Energy Technology Data Exchange (ETDEWEB)

    Nunes, Maira G.; Rodrigues, Leticia L.C., E-mail: mgnunes@ipen.br [Instituto de Pesquisas Energerticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2012-12-15

    The calcium sulphate activated with cerium and europium (CaSO{sub 4}:Ce,Eu) thermoluminescent dosimeters (TLD) recently developed at Nuclear and Energy Research Institute as well as the calcium sulphate activated with dysprosium (CaSO{sub 4}: Dy) and lithium fluoride activated with magnesium and titanium, (LiF:Mg,Ti; TLD-100) TLDs, with long term applications in dosimetry and considered as standards, were used to obtain the dose profile for 3.43, 5.48, 8.27 and 11.67 MeV electron beams generated by a linear accelerator Clinac 2100-C (Varian) in the reference conditions defined by the TRS-398 code of practice. The routine dosimetry of the electron beams, performed with a calibrated ionization chamber, ensures that the electron beams fulfill the requirements of flatness and symmetry established in this code of practice. Thus, as the TRS-398 Code of Practice requirements are fulfilled by the measurements performed with the new TLD type, CaSO{sub 4}:Ce,Eu may be applied in clinical dosimetry of high energy electron beams. (author)

  19. Effects of High Intensity Interval Training on Increasing Explosive Power, Speed, and Agility

    Science.gov (United States)

    Fajrin, F.; Kusnanik, N. W.; Wijono

    2018-01-01

    High Intensity Interval Training (HIIT) is a type of exercise that combines high-intensity exercise and low intensity exercise in a certain time interval. This type of training is very effective and efficient to improve the physical components. The process of improving athletes achievement related to how the process of improving the physical components, so the selection of a good practice method will be very helpful. This study aims to analyze how is the effects of HIIT on increasing explosive power, speed, and agility. This type of research is quantitative with quasi-experimental methods. The design of this study used the Matching-Only Design, with data analysis using the t-test (paired sample t-test). After being given the treatment for six weeks, the results showed there are significant increasing in explosive power, speed, and agility. HIIT in this study used a form of exercise plyometric as high-intensity exercise and jogging as mild or moderate intensity exercise. Increase was due to the improvement of neuromuscular characteristics that affect the increase in muscle strength and performance. From the data analysis, researchers concluded that, Exercises of High Intensity Interval Training significantly effect on the increase in Power Limbs, speed, and agility.

  20. Keratorefractive Effect of High Intensity Focused Ultrasound Keratoplasty on Rabbit Eyes

    Directory of Open Access Journals (Sweden)

    Zhiyu Du

    2016-01-01

    Full Text Available Purpose. To evaluate high intensity focused ultrasound (HIFU as an innovation and noninvasive technique to correct presbyopia by altering corneal curvature in the rabbit eye. Methods. Eighteen enucleated rabbit eyes were treated with a prototype HIFU keratoplasty. According to the therapy power, these eyes were divided three groups: group 1 (1 W, group 2 (2 W, and group 3 (3 W. The change in corneal power was quantified by a Sirius Scheimpflug camera. Light microscopy (LM and transmission electron microscopy (TEM were performed to determine the effect on the corneal stroma. Results. In the treated eyes, the corneal curvature increases from 49.42 ± 0.30 diopters (D and 48.00 ± 1.95 D before procedure to 51.37 ± 1.11 D and 57.00 ± 1.84 D after HIFU keratoplasty application in groups 1 and 3, respectively. The major axis and minor axis of the focal region got longer when the powers of the HIFU got increased; the difference was statistically significant (p<0.05. LM and TEM showed HIFU-induced shrinkage of corneal stromal collagen with little disturbance to the underlying epithelium. Conclusions. We have preliminarily exploited HIFU to establish a new technique for correcting presbyopia. HIFU keratoplasty will be a good application prospect for treating presbyopia.

  1. Vacuum ultraviolet Ar2*laser pumped by a high-intensity laser

    International Nuclear Information System (INIS)

    Kubodera, Shoichi; Kaku, Masanori; Higashiguchi, Takeshi

    2004-01-01

    We observed a small-signal gain of Ar 2 * emission at 126 nm by use of an Ar-filled hollow fiber to guide the ultrashort-pulse high-intensity laser propagation. The small signal gain coefficient was measured to be 0.05 cm -1 at 126 nm. Kinetic analysis revealed that the electrons produced by the high-intensity laser through an optical-field ionization process initiated the Ar 2 * production process. This laser scheme could be combined with high harmonic radiation of the pump laser in the vacuum ultraviolet (VUV), leading to the production of amplified ultrashort VUV pulses. (author)

  2. Ultrasound-guided high-intensity focused ultrasound treatment for abdominal wall endometriosis: Preliminary results

    International Nuclear Information System (INIS)

    Wang Yang; Wang Wei; Wang Longxia; Wang Junyan; Tang Jie

    2011-01-01

    Purpose: To evaluate the safety and therapeutic efficacy of ultrasound (US)-guided high-intensity focused ultrasound (HIFU) ablation for the treatment of abdominal wall endometriosis (AWE). Materials and methods: Twenty-one consecutive patients with AWE were treated as outpatients by US-guided HIFU ablation under conscious sedation. The median size of the AWE was 2.4 cm (range 1.0-5.3 cm). An acoustic power of 200-420 W was used, intermittent HIFU exposure of 1 s was applied. Treatment was considered complete when the entire nodule and its nearby 1 cm margin become hyperechoic on US. Pain relief after HIFU ablation was observed and the treated nodule received serial US examinations during follow-up. Results: All AWE was successfully ablated after one session of HIFU ablation, the ablation time lasted for 5-48 min (median 13 min), no major complications occurred. The cyclic pain disappeared in all patients during a mean follow-up of 18.7 months (range 3-31 months). The treated nodules gradually shank over time, 16 nodules became unnoticeable on US during follow-up. Conclusion: US-guided HIFU ablation appears to be safe and effective for the treatment of AWE.

  3. Ultrasound-guided high-intensity focused ultrasound treatment for abdominal wall endometriosis: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yang [Department of Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China); Wang Wei, E-mail: wangyang301301@yahoo.com.cn [Department of Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China); Wang Longxia; Wang Junyan; Tang Jie [Department of Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China)

    2011-07-15

    Purpose: To evaluate the safety and therapeutic efficacy of ultrasound (US)-guided high-intensity focused ultrasound (HIFU) ablation for the treatment of abdominal wall endometriosis (AWE). Materials and methods: Twenty-one consecutive patients with AWE were treated as outpatients by US-guided HIFU ablation under conscious sedation. The median size of the AWE was 2.4 cm (range 1.0-5.3 cm). An acoustic power of 200-420 W was used, intermittent HIFU exposure of 1 s was applied. Treatment was considered complete when the entire nodule and its nearby 1 cm margin become hyperechoic on US. Pain relief after HIFU ablation was observed and the treated nodule received serial US examinations during follow-up. Results: All AWE was successfully ablated after one session of HIFU ablation, the ablation time lasted for 5-48 min (median 13 min), no major complications occurred. The cyclic pain disappeared in all patients during a mean follow-up of 18.7 months (range 3-31 months). The treated nodules gradually shank over time, 16 nodules became unnoticeable on US during follow-up. Conclusion: US-guided HIFU ablation appears to be safe and effective for the treatment of AWE.

  4. Beam dynamics of mixed high intensity highly charged ion Beams in the Q/A selector

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X.H., E-mail: zhangxiaohu@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Yuan, Y.J.; Yin, X.J.; Qian, C.; Sun, L.T. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Du, H.; Li, Z.S.; Qiao, J.; Wang, K.D. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Zhao, H.W.; Xia, J.W. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China)

    2017-06-11

    Electron cyclotron resonance (ECR) ion sources are widely used in heavy ion accelerators for their advantages in producing high quality intense beams of highly charged ions. However, it exists challenges in the design of the Q/A selection systems for mixed high intensity ion beams to reach sufficient Q/A resolution while controlling the beam emittance growth. Moreover, as the emittance of beam from ECR ion sources is coupled, the matching of phase space to post accelerator, for a wide range of ion beam species with different intensities, should be carefully studied. In this paper, the simulation and experimental results of the Q/A selection system at the LECR4 platform are shown. The formation of hollow cross section heavy ion beam at the end of the Q/A selector is revealed. A reasonable interpretation has been proposed, a modified design of the Q/A selection system has been committed for HIRFL-SSC linac injector. The features of the new design including beam simulations and experiment results are also presented.

  5. Comparison of Serum CA72-4 and CEA Levels in Patient with Endoscopically Suspected Gastric Carcinoma.

    Science.gov (United States)

    Rehena, Z; Ghosh, C K; Afroz, F; Alam, M B; Ferdousi, S; Mahmuduzzaman, M; Sultana, T; Ahmed, A N

    2015-07-01

    Several serum tumour markers have been described for gastric cancer. Preoperative level of tumor marker helps to predict the diagnosis of gastric carcinoma. CA72-4 as a serum tumour marker for gastric cancer is evaluated, and compared its utility in this regard with that of carcinoembryonic antigen (CEA). Analysis of gastric carcinoma by serum levels of CEA and CA72-4 and their correlation with histopathology help the clinician to develop his management strategies for gastric carcinoma. A prospective observational study was carried out in the Department of Clinical Pathology, Bangabandhu Sheikh Mujib Medical University (BSMMU) in collaboration with Department of Surgery BSMMU, DMCH, Delta Hospital Limited, Dhaka, during the period of October 2010 to September 2011. Serum CA72-4 and CEA were analyzed in 71 endoscopically suspected patients for gastric carcinoma. Among them 58 cases were diagnosed as malignant gastric disease and 13 cases were nonmalignant gastric disease. Sensitivity of CA 72-4 and CEA were 48.3% and 31% respectively and specificity were 92.3% and 76.9% respectively. In poorly differentiated carcinoma, positivity for CA72-4 and CEA were 55.6% and 36.1% respectively. Because of the high positivity of CA72-4 in poorly differentiated carcinoma, CA72-4 is reliable tumour marker in advanced cases. As the sensitivity of CA72-4 was more than that of CEA in diagnosis of gastric cancer, CA72-4 can be used in conjunction with other diagnostic tests like endoscopy that would be more helpful for the patients.

  6. Practicing Reiki does not appear to routinely produce high-intensity electromagnetic fields from the heart or hands of Reiki practitioners.

    Science.gov (United States)

    Baldwin, Ann Linda; Rand, William Lee; Schwartz, Gary E

    2013-06-01

    The study objective was to determine whether Reiki practice increases the electromagnetic field strength from the heart and hands of Reiki practitioners. This study repeated experiments performed 20 years ago that detected exceptionally high-strength electromagnetic fields (100 nT) from the hands of several energy healers. The equipment used was far more sensitive than in the original studies. Using a Magnes 2500 WH SQUID, the electromagnetic field from the hands and heart of each of 3 Reiki masters was measured when they were (1) not practicing Reiki, (2) sending Reiki to a distant person, and (3) sending Reiki to a person in the room. Similar measurements were made on 4 Reiki-naïve volunteers before and after they received a Reiki training/attunement enabling them to self-administer Reiki. The study setting was the Scripps Institute, San Diego, CA. Magnetic field intensity of hands and heart recorded over 5-minute sessions with corresponding frequency spectra. For all subjects, under all conditions, sensors closest to the heart and the hands produced spikes of 2 pT corresponding to the heartbeat. Recordings from 2 Masters and 1 volunteer showed a low-intensity sine wave oscillation of 0.25-0.3 Hz (intensity 0.1-0.5 pT) whether or not they were practicing Reiki. This oscillation probably reflected respiratory sinus arrhythmia, judged by comparison with recent previous studies. These signals were not detected in the original studies. In the current study, no electromagnetic field intensities greater than 3 pT were observed in any of the recordings. Practicing Reiki does not appear to routinely produce high-intensity electromagnetic fields from the heart or hands. Alternatively, it is possible that energy healing is stimulated by tuning into an external environmental radiation, such as the Schumann resonance, which was blocked in the present study by the strong magnetic shielding surrounding the SQUID.

  7. Excitation contraction uncoupling by high intracellular [Ca2+] in frog skeletal muscle: a voltage clamp study.

    Science.gov (United States)

    Olivera, J Fernando; Pizarro, Gonzalo

    2016-10-01

    Raising the intracellular [Ca 2+ ] ([Ca 2+ ] i ) was previously found to produce uncoupling between the electrical depolarization of the transverse tubules and contraction in skinned muscle fibers. Here we study the effect of elevated [Ca 2+ ] i in voltage clamped cut fibers of frog skeletal muscle to establish how the charge movement, a measure of the activation of the dihydropyridine receptors (DHPR)-voltage sensors, and Ca 2+ release, a consequence of the opening of the ryanodine receptor (RyR)-release channels, were affected. [Ca 2+ ] i was raised by various procedures (pharmacological release from the sarcoplasmic reticulum, application of high [Ca 2+ ] i intracellular solution, permeabilization of the plasma membrane by a Ca 2+ ionophore) all of which produced impairment of excitation-contraction coupling. The charge movement was reduced from 20.2 ± 1.24 to 9.9 ± 0.94 nC/μF meanwhile the Ca 2+ release flux was reduced from 13.5 + 0.7 to 2.2 ± 0.3 μM/ms (n = 33). This suggests that a significant fraction of the DHPRs that remained functional, could not activate RyRs, and were therefore presumably disconnected. These results are broadly consistent with the original reports in skinned fibers. Uncoupling was prevented by the addition to the intracellular solution of the protease inhibitor leupeptin. In approximately 40 % of the uncoupled cells we observed that the [Ca 2+ ] i transient continued to rise after the voltage clamp pulse was turned off. This loss of control by membrane voltage suggests that the uncoupled release channels might have another mechanism of activation, likely by Ca 2+ .

  8. High-Intensity Interval Training for Improving Postprandial Hyperglycemia

    Science.gov (United States)

    Little, Jonathan P.; Francois, Monique E.

    2014-01-01

    High-intensity interval training (HIIT) has garnered attention in recent years as a time-efficient exercise option for improving cardiovascular and metabolic health. New research demonstrates that HIIT may be particularly effective for improving postprandial hyperglycemia in individuals with, or at risk for, type 2 diabetes (T2D). These findings…

  9. Simulation study of the high intensity S-Band photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Xiongwei; Nakajima, Kazuhisa [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan)

    2001-10-01

    In this paper, we report the results of simulation study of the high intensity S-Band photoinjector. The aim of the simulation study is to transport high bunch charge with low emittance evolution. The simulation result shows that 7nC bunch with rms emittance 22.3 {pi} mm mrad can be outputted at the exit of photoinjector. (author)

  10. Simulation study of the high intensity S-Band photoinjector

    International Nuclear Information System (INIS)

    Zhu, Xiongwei; Nakajima, Kazuhisa

    2001-01-01

    In this paper, we report the results of simulation study of the high intensity S-Band photoinjector. The aim of the simulation study is to transport high bunch charge with low emittance evolution. The simulation result shows that 7nC bunch with rms emittance 22.3 π mm mrad can be outputted at the exit of photoinjector. (author)

  11. Interaction of intense femtosecond laser pulses with high-Z solids

    International Nuclear Information System (INIS)

    Zhidkov, A.; Sasaki, Akira; Utsumi, Takayuki; Fukumoto, Ichirou; Tajima, Toshiki; Yoshida, Masatake; Kondo, Kenichi

    2000-01-01

    A plasma irradiated by an intense very short pulse laser can be an ultimate high brightness source of incoherent inner-shell X-ray emission of 1-30 keV. The recently developed 100 TW, 20 fs laser facility in JAERI can make considerable enhancement here. To show this a hybrid model combining hydrodynamics and collisional particle-in-cell simulations is applied. Effect of laser prepulse on the interaction of an intense s-polarized femtosecond, ∼20/40 fs, laser pulse with high-Z solid targets is studied. A new absorption mechanism originating from the interaction of the laser pulse with plasma waves excited by the relativistic component of the Lorentz force is found to increase the absorption rate over 30% even for a very short laser pulse. The obtained hot electron temperature exceeds 0.5-1 MeV at optimal conditions for absorption. Results of the simulation for lower laser pulse intensities are in good agreement with the experimental measurements of the hot electron energy distribution. (author)

  12. Removing Known SPS Intensity Limitations for High Luminosity LHC Goals

    CERN Document Server

    Shaposhnikova, Elena; Bohl, Thomas; Cruikshank, Paul; Goddard, Brennan; Kaltenbacher, Thomas; Lasheen, Alexandre; Perez Espinos, Jaime; Repond, Joël; Salvant, Benoit; Vollinger, Christine

    2016-01-01

    In preparation of the SPS as an LHC injector its impedance was significantly reduced in 1999 - 2000. A new SPS impedance reduction campaign is planned now for the High Luminosity (HL)-LHC project, which requires bunch intensities twice as high as the nominal one. One of the known intensity limitations is a longitudinal multi-bunch instability with a threshold 3 times below this operational intensity. The instability is presently cured using the 4th harmonic RF system and controlled emittance blow-up, but reaching the HL-LHC parameters cannot be assured without improving the machine impedance. Recently the impedance sources responsible for this instability were identified and implementation of their shielding and damping is foreseen during the next long shutdown (2019 - 2020) in synergy with two other important upgrades: amorphous carbon coating of (part of) the vacuum chamber against the e-cloud effect and rearrangement of the 200 MHz RF system. In this paper the strategy of impedance reduction is presented t...

  13. Fluorescent and high intensity discharge lamp use in chambers and greenhouses

    Science.gov (United States)

    Langhans, Robert W.

    1994-01-01

    Fluorescent and High Intensity Discharge lamps have opened up great opportunities for researchers to study plant growth under controlled environment conditions and for commercial growers to increase plant production during low/light periods. Specific technical qualities of fluorescent and HID lamps have been critically reviewed. I will direct my remarks to fluorescent and high intensity discharge (HID) lamps in growth chambers, growth rooms, and greenhouses. I will discuss the advantages and disadvantages of using each lamp in growth chambers, growth rooms and greenhouses.

  14. High-intensity interval training (HIIT) for patients with chronic diseases

    OpenAIRE

    Ross, Leanna M.; Porter, Ryan R.; Durstine, J. Larry

    2016-01-01

    Exercise training provides physiological benefits for both improving athletic performance and maintaining good health. Different exercise training modalities and strategies exist. Two common exercise strategies are high-intensity interval training (HIIT) and moderate-intensity continuous exercise training (MCT). HIIT was first used early in the 20th century and popularized later that century for improving performance of Olympic athletes. The primary premise underlying HIIT is that, compared t...

  15. 76 FR 44613 - Designation of Eight Counties as High Intensity Drug Trafficking Areas

    Science.gov (United States)

    2011-07-26

    ... OFFICE OF NATIONAL DRUG CONTROL POLICY Designation of Eight Counties as High Intensity Drug Trafficking Areas AGENCY: Office of National Drug Control Policy. ACTION: Notice. SUMMARY: The Director of the Office of National Drug Control Policy has designated eight additional counties as High Intensity Drug...

  16. Intense heavy ion beam-induced temperature effects in carbon-based stripper foils

    International Nuclear Information System (INIS)

    Kupka, K.; Tomut, M.; Simon, P.; Hubert, C.; Romanenko, A.; Lommel, B.; Trautmann, C.

    2015-01-01

    At the future FAIR facility, reliably working solid carbon stripper foils are desired for providing intermediate charge states to SIS18. With the expected high beam intensities, the foils experience enhanced degradation and limited lifetime due to severe radiation damage, stress waves, and thermal effects. This work presents systematic measurements of the temperature of different carbon-based stripper foils (amorphous, diamond-like, and carbon-nanotube based) exposed to 4.8 MeV/u U, Bi, and Au beams of different pulse intensities. Thermal and spectroscopic analyses were performed by means of infrared thermography and Fourier transform infrared spectroscopy. The resulting temperature depends on the foil thickness and strongly increases with increasing pulse intensity and repetition rate. (author)

  17. High-intensity deuteron linear accelerator (FMIT)

    International Nuclear Information System (INIS)

    Jameson, R.A.

    1979-01-01

    For fusion reactors to become operational, one of the many problems to be solved is to find materials able to withstand the intense bombardment of 14-MeV neutrons released by the fusion process. The development of alloys less likely to become damaged by this neutron bombardment will require years of work, making it desirable to begin studies in parallel with other aspects of fusion power generators. The Fusion Materials Irradiation Test (FMIT) Facility, to be built at the Hanford Engineering Development Laboratory (HEDL), Richland, Washington, will provide a high neutron flux and a neutron energy spectrum representative of fusion reactor conditions in volumes adequate to screen and qualify samples of candidate fusion reactor materials. FMIT's design goal is to provide an irradiation test volume of 10 cm 3 at a neutron flux of 10 15 n/cm 2 -s, and 500 cm 3 at a flux of 10 14 n/cm 2 -s. This will not allow testing of actual components, but samples in the most intense flux region can be subjected to accelerated life testing, accumulating in one year the total number of neutrons seen by a fusion reactor in 10 to 20 years of operation

  18. Moderate-to-High Intensity Physical Exercise in Patients with Alzheimer's Disease

    DEFF Research Database (Denmark)

    Hoffmann, Kristine; Sobol, Nanna A; Frederiksen, Kristian S

    2016-01-01

    BACKGROUND: Studies of physical exercise in patients with Alzheimer's disease (AD) are few and results have been inconsistent. OBJECTIVE: To assess the effects of a moderate-to-high intensity aerobic exercise program in patients with mild AD. METHODS: In a randomized controlled trial, we recruite...... reduced neuropsychiatric symptoms in patients with mild AD, with possible additional benefits of preserved cognition in a subgroup of patients exercising with high attendance and intensity.......BACKGROUND: Studies of physical exercise in patients with Alzheimer's disease (AD) are few and results have been inconsistent. OBJECTIVE: To assess the effects of a moderate-to-high intensity aerobic exercise program in patients with mild AD. METHODS: In a randomized controlled trial, we recruited...... 200 patients with mild AD to a supervised exercise group (60-min sessions three times a week for 16 weeks) or to a control group. Primary outcome was change from baseline in cognitive performance estimated by Symbol Digit Modalities Test (SDMT) in the intention-to-treat (ITT) group. Secondary outcomes...

  19. Design features and performance of the LAMPF high-intensity beam area

    International Nuclear Information System (INIS)

    Agnew, L.; Grisham, D.; Macek, R.J.; Sommer, W.F.; Werbeck, R.D.

    1983-01-01

    LAMPF is a multi-purpose high-intensity meson factory capable of producing a 1 mA beam of 800-MeV protons. The three target cells and the beam stop facilities in the high intensity area have many special design features that are required for operation in the presence of high heat loads and intense radiation fields where accessibility is extremely limited. Reliable targets, beam windows, beam stops, beam transport and diagnostic components, vacuum enclosures, and auxiliary systems have been developed. Sophisticated remote-handling systems are employed for maintenance. Complex protection systems have been developed to guard against damage caused by errant beam. Beam availability approaching 90% has been achieved at currents of 600 to 700 μA. A new facility for direct proton and neutron radiation effects studies will be installed in 1985. The new facility will provide an integrated spallation neutron flux of up to 5 x 10 17 m -2 s -1 and will anable proton irradiation studies in the primary beam

  20. High signal intensity of the septum pellucidum at MR imaging; Significance in hydrocephalus

    International Nuclear Information System (INIS)

    Yoon, Jeong Hee; Kim, Eun Ha; Chung, Chun Phil; Kim, Chang Soo

    1994-01-01

    To evaluate the significance of high signal intensity of the septum pellucidum in hydrocephalus on proton density-weighted brain MR images. Authors reviewed the MR images of 418 cases of patients with normal (175 case), hydrocephalic(35 cases), atrophic(58 cases), and other groups(150 cases) retrospectively. We analyzed the signal intensity of the septum pellucidum in the normal group and the incidences of high signal intensities of periventricular area of frontal horn of lateral ventricle(area 1), periventricular area except area 1 (area 2), callososeptal area(area 3), and septum pellucidum(area 4) in the normal and abnormal groups. In the normal group, the septum pellucidum was isointense to the head of caudate nucleus on proton density-weighted image. High signal intensity of the septum pellucidum was seen in 31 cases (22 cases of hydrocephalus, 5 cases of brain atrophy, and 4 cases of others), and showed high specificity(91.4%) for hydrocephalus in spite of low sensitivity(62.9%), as compared with periventricular hyperintensities of other areas. High signal intensity of the septum pellucidum on proton density- weighted image may be caused by transependymal CSF migration in the patients with hydrocephalus, and considered as an additional finding of hydrocephalus in the cases of ventriculomegaly

  1. Tumor markers in the early detection of tumor recurrence in breast cancer patients: CA 125, CYFRA 21-1, HER2 shed antigen, LDH and CRP in combination with CEA and CA 15-3.

    Science.gov (United States)

    Di Gioia, Dorit; Blankenburg, Irene; Nagel, Dorothea; Heinemann, Volker; Stieber, Petra

    2016-10-01

    Kinetics of CA 15-3 and CEA have a high specificity in the early detection of metastatic breast cancer (MBC). However, this high specificity is associated with a lack of sensitivity. To decrease the number of false negative patients, the additional diagnostic potential of an extended panel of biomarkers was evaluated. This analysis was performed as part of a large follow-up study (1998-2010) evaluating 813 patients with a median follow-up of 63months. After primary therapy, all patients underwent tumor marker monitoring for CEA and CA 15-3 at 6-week intervals. A reproducible previously defined increase (≥100%) based on the individual baseline value of each patient was considered as a strong indicator of MBC. For the present analysis, we retrospectively evaluated 1011 blood samples from 95 patients. Forty-seven of these had metastatic disease for the first time at the time of this evaluation, while the remaining 48 patients showed no evidence of disease. The sera of these patients were additionally assessed for the following parameters: cancer antigen (CA) 125, cytokeratin-19 soluble fragment (CYFRA 21-1), HER2 shed antigen, lactate-dehydrogenase (LDH) and C-reactive protein (CRP). 26 of 47 patients with MBC showed a reproducible tumor marker increase of at least CEA and/or CA 15-3 (55.3%, true-positive). The remaining 21 patients with MBC showed no increase in CEA or CA 15-3 (44.7%, false negative, FN). By combining all markers mentioned above, 41 of 47 patients with MBC showed a reproducible marker increase with a sensitivity of 87.2% and specificity of 100%. This retrospective analysis indicates that a panel of biomarkers can increase the sensitivity of the CA 15-3/CEA combination without loss of specificity. The combined use is therefore helpful for early detection of MBC. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Self-guiding of high-intensity laser pulses for laser wake field acceleration

    International Nuclear Information System (INIS)

    Umstader, D.; Liu, X.

    1992-01-01

    A means of self-guiding an ultrashort and high-intensity laser pulse is demonstrated both experimentally and numerically. Its relevance to the laser wake field accelerator concept is discussed. Self-focusing and multiple foci formation are observed when a high peak power (P>100 GW), 1 μm, subpicosecond laser is focused onto various gases (air or hydrogen). It appears to result from the combined effects of self-focusing by the gas, and de-focusing both by diffraction and the plasma formed in the central high-intensity region. Quasi-stationary computer simulations show the same multiple foci behavior as the experiments. The results suggest much larger nonlinear electronic susceptibilities of a gas near or undergoing ionization in the high field of the laser pulse. Although self-guiding of a laser beam by this mechanism appears to significantly extend its high-intensity focal region, small-scale self-focusing due to beam non-uniformity is currently a limitation

  3. Formation of CaB6 in the thermal decomposition of the hydrogen storage material Ca(BH4)2.

    Science.gov (United States)

    Sahle, Christoph J; Sternemann, Christian; Giacobbe, Carlotta; Yan, Yigang; Weis, Christopher; Harder, Manuel; Forov, Yury; Spiekermann, Georg; Tolan, Metin; Krisch, Michael; Remhof, Arndt

    2016-07-20

    Using a combination of high resolution X-ray powder diffraction and X-ray Raman scattering spectroscopy at the B K- and Ca L2,3-edges, we analyzed the reaction products of Ca(BH4)2 after annealing at 350 °C and 400 °C under vacuum conditions. We observed the formation of nanocrystalline/amorphous CaB6 mainly and found only small contributions from amorphous B for annealing times larger than 2 h. For short annealing times of 0.5 h at 400 °C we observed neither CaB12H12 nor CaB6. The results indicate a reaction pathway in which Ca(BH4)2 decomposes to B and CaH2 and finally reacts to form CaB6. These findings confirm the potential of using Ca(BH4)2 as a hydrogen storage medium and imply the desired cycling capabilities for achieving high-density hydrogen storage materials.

  4. Development and validation of a 48-target analytical method for high-throughput monitoring of genetically modified organisms.

    Science.gov (United States)

    Li, Xiaofei; Wu, Yuhua; Li, Jun; Li, Yunjing; Long, Likun; Li, Feiwu; Wu, Gang

    2015-01-05

    The rapid increase in the number of genetically modified (GM) varieties has led to a demand for high-throughput methods to detect genetically modified organisms (GMOs). We describe a new dynamic array-based high throughput method to simultaneously detect 48 targets in 48 samples on a Fludigm system. The test targets included species-specific genes, common screening elements, most of the Chinese-approved GM events, and several unapproved events. The 48 TaqMan assays successfully amplified products from both single-event samples and complex samples with a GMO DNA amount of 0.05 ng, and displayed high specificity. To improve the sensitivity of detection, a preamplification step for 48 pooled targets was added to enrich the amount of template before performing dynamic chip assays. This dynamic chip-based method allowed the synchronous high-throughput detection of multiple targets in multiple samples. Thus, it represents an efficient, qualitative method for GMO multi-detection.

  5. Chemical Abundance Evidence of Enduring High Star Formation Rates in an Early-type Galaxy: High [Ca/Fe] in NGC 5128 Globular Clusters

    Science.gov (United States)

    Colucci, Janet E.; Fernanda Durán, María; Bernstein, Rebecca A.; McWilliam, Andrew

    2013-08-01

    We present [Fe/H], ages, and Ca abundances for an initial sample of 10 globular clusters in NGC 5128 obtained from high-resolution, high signal-to-noise ratio echelle spectra of their integrated light. All abundances and ages are obtained using our original technique for high-resolution integrated light abundance analysis of globular clusters. The clusters have a range in [Fe/H] between -1.6 and -0.2. In this sample, the average [Ca/Fe] for clusters with [Fe/H] <-0.4 is +0.37 ± 0.07, while the average [Ca/Fe] in our Milky Way (MW) and M31 GC samples is +0.29 ± 0.09 and +0.24 ± 0.10, respectively. This may imply a more rapid chemical enrichment history for NGC 5128 than for either the MW or M31. This sample provides the first quantitative picture of the chemical history of NGC 5128 that is directly comparable to what is available for the MW. Data presented here were obtained with the MIKE echelle spectrograph on the Magellan Clay Telescope. This Letter includes data gathered with the 6.5 m Magellan Telescopes located at Las Campanas Observatory, Chile.

  6. 48Ca+249Bk fusion reaction leading to element Z = 117: long-lived α-decaying 270Db and discovery of 266Lr.

    Science.gov (United States)

    Khuyagbaatar, J; Yakushev, A; Düllmann, Ch E; Ackermann, D; Andersson, L-L; Asai, M; Block, M; Boll, R A; Brand, H; Cox, D M; Dasgupta, M; Derkx, X; Di Nitto, A; Eberhardt, K; Even, J; Evers, M; Fahlander, C; Forsberg, U; Gates, J M; Gharibyan, N; Golubev, P; Gregorich, K E; Hamilton, J H; Hartmann, W; Herzberg, R-D; Heßberger, F P; Hinde, D J; Hoffmann, J; Hollinger, R; Hübner, A; Jäger, E; Kindler, B; Kratz, J V; Krier, J; Kurz, N; Laatiaoui, M; Lahiri, S; Lang, R; Lommel, B; Maiti, M; Miernik, K; Minami, S; Mistry, A; Mokry, C; Nitsche, H; Omtvedt, J P; Pang, G K; Papadakis, P; Renisch, D; Roberto, J; Rudolph, D; Runke, J; Rykaczewski, K P; Sarmiento, L G; Schädel, M; Schausten, B; Semchenkov, A; Shaughnessy, D A; Steinegger, P; Steiner, J; Tereshatov, E E; Thörle-Pospiech, P; Tinschert, K; Torres De Heidenreich, T; Trautmann, N; Türler, A; Uusitalo, J; Ward, D E; Wegrzecki, M; Wiehl, N; Van Cleve, S M; Yakusheva, V

    2014-05-02

    The superheavy element with atomic number Z=117 was produced as an evaporation residue in the (48)Ca+(249)Bk fusion reaction at the gas-filled recoil separator TASCA at GSI Darmstadt, Germany. The radioactive decay of evaporation residues and their α-decay products was studied using a detection setup that allowed measuring decays of single atomic nuclei with half-lives between sub-μs and a few days. Two decay chains comprising seven α decays and a spontaneous fission each were identified and are assigned to the isotope (294)117 and its decay products. A hitherto unknown α-decay branch in (270)Db (Z = 105) was observed, which populated the new isotope (266)Lr (Z = 103). The identification of the long-lived (T(1/2) = 1.0(-0.4)(+1.9) h) α-emitter (270)Db marks an important step towards the observation of even more long-lived nuclei of superheavy elements located on an "island of stability."

  7. Calcium in pollen-pistil interaction in `Petunia hybrida Hat`. Pt. 3. Localization of Ca{sup 2+} ions and Ca{sup 2+}-ATPase in pollinated pistil

    Energy Technology Data Exchange (ETDEWEB)

    Bednarska, E.; Butowt, R. [Uniwersytet Mikolaja Kopernika, Torun (Poland)

    1995-12-31

    Studies were carried out of Ca{sup 2+} and Ca{sup 2+}-ATPase localization in pollinated (6 and 48 h after pollination) pistils of `Petunia hybrida`. The results were confronted with Ca{sup 2+} localization in mature pollen grain and in unpollinated pistil. It has been found that after pollination the number of Ca{sup 2+} sequestered in the stigmal exudate and in the sporoderm of the pollen grain gets lower. That phenomenon was associated with the appearance of a large number of Sb/Ca precipitates in the submembrane cytoplasm of the germinating pollen. In the vacuolized pollen grain, i.e. grown into a pollen tube, there were only a few precipitates. In the pollen tube, Ca{sup 2+} were found in the organelles of the tip cytoplasm and in the external pectin cell wall. Studies with the use of {sup 45}Ca{sup 2+} have revealed that the source of calcium ions incorporated into the pollen tube tip and its pectin wall is the transmitting tract of the style. In the transmitting tract overgrown with pollen tubes, Ca{sup 2+} were localized in the intercellular matrix and in the transmitting cell. Sb/Ca precipitates occurred in the nuclei, around the secretary vesicles and on the plasmalemma in the transverse walls region. Elevated Ca{sup 2+} level was found in degenerating cells (inhibited pollen tubes, transmitting cells, nucellar cells). The progressing degeneration process of the cells of the transmitting tract of the pollinated pistil was associated with a decrease in the activity of plasmalemma Ca{sup 2+}-ATPase. (author). 30 refs, 19 figs.

  8. Pulsed x-ray imaging of high-density objects using a ten picosecond high-intensity laser driver

    Science.gov (United States)

    Rusby, D. R.; Brenner, C. M.; Armstrong, C.; Wilson, L. A.; Clarke, R.; Alejo, A.; Ahmed, H.; Butler, N. M. H.; Haddock, D.; Higginson, A.; McClymont, A.; Mirfayzi, S. R.; Murphy, C.; Notley, M.; Oliver, P.; Allott, R.; Hernandez-Gomez, C.; Kar, S.; McKenna, P.; Neely, D.

    2016-10-01

    Point-like sources of X-rays that are pulsed (sub nanosecond), high energy (up to several MeV) and bright are very promising for industrial and security applications where imaging through large and dense objects is required. Highly penetrating X-rays can be produced by electrons that have been accelerated by a high intensity laser pulse incident onto a thin solid target. We have used a pulse length of 10ps to accelerate electrons to create a bright x-ray source. The bremsstrahlung temperature was measured for a laser intensity from 8.5-12×1018 W/cm2. These x-rays have sequentially been used to image high density materials using image plate and a pixelated scintillator system.

  9. Ca2 Al2 SiO7 :Ce3+ phosphors for mechanoluminescence dosimetry.

    Science.gov (United States)

    Tiwari, Geetanjali; Brahme, Nameeta; Sharma, Ravi; Bisen, D P; Sao, Sanjay Kumar; Sahu, Ishwar Prasad

    2016-12-01

    A series of Ce 3+ ion single-doped Ca 2 Al 2 SiO 7 phosphors was synthesized by a combustion-assisted method at an initiating temperature of 600 °C. The samples were annealed at 1100 °C for 3 h and their X-ray diffraction patterns confirmed a tetragonal structure. The phase structure, particle size, surface morphology and elemental analysis were analyzed using X-ray diffraction (XRD), transmission electron microscope (TEM), scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) spectroscopy techniques. Thermoluminescence (TL) intensity increased with increase in ultraviolet (UV) light exposure time up to 15 min. With further increase in the UV irradiation time the TL intensity decreases. The increase in TL intensity indicates that trap concentration increased with UV exposure time. A broad peak at 121 °C suggested the existence of a trapping level. The peak of mechanoluminescence (ML) intensity versus time curve increased linearly with increasing impact velocity of the moving piston. Mechanoluminescence intensity increased with increase in UV irradiation time up to 15 min. Under UV-irradiation excitation, the TL and ML emission spectra of Ca 2 Al 2 SiO 7 :Ce 3+ phosphor showed the characteristic emission of Ce 3+ peaking at 400 nm (UV-violet) and originating from the Ce 3+ transitions of 5d-4f ( 2 F 5/2 and 2 F 7/2 ). The photoluminescence (PL) emission spectra for Ca 2 Al 2 SiO 7 :Ce 3+ were similar to the ML/TL emission spectra. The mechanism of ML excitation and the suitability of the Ca 2 Al 2 SiO 7 :Ce 3+ phosphor for radiation dosimetry are discussed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Trends in Use of High-Intensity Statin Therapy After Myocardial Infarction, 2011 to 2014.

    Science.gov (United States)

    Rosenson, Robert S; Farkouh, Michael E; Mefford, Matthew; Bittner, Vera; Brown, Todd M; Taylor, Ben; Monda, Keri L; Zhao, Hong; Dai, Yuling; Muntner, Paul

    2017-06-06

    Data prior to 2011 suggest that a low percentage of patients hospitalized for acute coronary syndromes filled high-intensity statin prescriptions upon discharge. Black-box warnings, generic availability of atorvastatin, and updated guidelines may have resulted in a change in high-intensity statin use. The aim of this study was to examine trends and predictors of high-intensity statin use following hospital discharge for myocardial infarction (MI) between 2011 and 2014. Secular trends in high-intensity statin use following hospital discharge for MI were analyzed among patients 19 to 64 years of age with commercial health insurance in the MarketScan database (n = 42,893) and 66 to 75 years of age with U.S. government health insurance through Medicare (n = 75,096). Patients filling statin prescriptions within 30 days of discharge were included. High-intensity statins included atorvastatin 40 or 80 mg and rosuvastatin 20 or 40 mg. The percentage of beneficiaries whose first statin prescriptions filled following hospital discharge for MI were for high-intensity doses increased from 33.5% in January through March 2011 to 71.7% in October through November 2014 in MarketScan and from 24.8% to 57.5% in Medicare. Increases in high-intensity statin use following hospital discharge occurred over this period among patients initiating treatment (30.6% to 72.0% in MarketScan and 21.1% to 58.8% in Medicare) and those taking low- or moderate-intensity statins prior to hospitalization (from 27.8% to 62.3% in MarketScan and from 12.6% to 45.1% in Medicare). In 2014, factors associated with filling high-intensity statin prescriptions included male sex, filling beta-blocker and antiplatelet agent prescriptions, and attending cardiac rehabilitation within 30 days following discharge. The use of high-intensity statins following hospitalization for MI increased progressively from 2011 through 2014. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier

  11. The high intensity {gamma}-ray source (HI{gamma}S) and recent results

    Energy Technology Data Exchange (ETDEWEB)

    Tonchev, A.P. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States)]. E-mail: tonchev@tunl.duke.edu; Boswell, M. [University of North Carolina at Chapel Hill and TUNL, Chapel Hill, NC 27599 (United States); Howell, C.R. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States); Karwowski, H.J. [University of North Carolina at Chapel Hill and TUNL, Chapel Hill, NC 27599 (United States); Kelley, J.H. [North Carolina State University and TUNL, Raleigh, NC 27695 (United States); Tornow, W. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States); Wu, Y.K. [Duke University and Duke Free Electron Laser Laboratory, Durham, NC 27708-0319 (United States)

    2005-12-15

    The high intensity {gamma}-ray source (HI{gamma}S) utilizes intra-cavity backscattering of free electron laser photons from the Duke electron storage ring to produce a unique monoenergetic beam of high-flux {gamma}-rays with high polarization and selectable energy resolution. At present, {gamma}-ray beams with energies from 2 to 58 MeV are available with intensities as high as 10{sup 5}-5 x 10{sup 6} {gamma}/s, energy spreads of 3% or better, and nearly 100% linear polarization. The quality and intensity of the {gamma}-ray beams at HI{gamma}S are responsible for the unprecedented performance of this facility in a broad range of research programs in nuclear structure, nuclear astrophysics and nuclear applications. Recent results from excitation of isomeric states in ({gamma}, n) reactions and parity assignments of dipole states determined via the ({gamma}, {gamma}') reaction are presented.

  12. Proton and Ion Sources for High Intensity Accelerators

    CERN Multimedia

    Scrivens, R

    2004-01-01

    Future high intensity ion accelerators, including the Spallation Neutron Source (SNS), the European Spallation Source (ESS), the Superconducting Proton Linac (SPL) etc, will require high current and high duty factor sources for protons and negative hydrogen ions. In order to achieve these goals, a comparison of the Electron Cyclotron Resonance, radio-frequency and Penning ion sources, among others, will be made. For each of these source types, the present operational sources will be compared to the state-of-the-art research devices with special attention given to reliability and availability. Finally, the future research and development aims will be discussed.

  13. High-intensity, thin-target He-jet production source

    International Nuclear Information System (INIS)

    Bai, Y.; Vieira, D.J.; Wouters, J.M.; Butler, G.W.; Rosenauer, Dk; Loebner, K.E.G.; Lind, V.G.; Phillips, D.R.

    1996-01-01

    A thin-target He-jet system suited to the production and rapid transport of non-volatile radioactive species has been successfully operated with proton beam intensities of up to 700 μA. The system consists of a water-cooled, thin-target chamber, capillary gas transport system, moving tape/Ge detection system, and an aerosol generator/gas recirculator. The yields for a wide variety of uranium fission and deep spallation products have been measured and robust operation of the system demonstrated for several weeks. He-jet transport and collection efficiencies ranged between 15 and 25% with collection rates of 10 7 to 10 8 atoms/sec/isotope. The high-intensity, thin-target He-jet approach represents a robust production source for nonvolatile radioactive heavy ion beams

  14. Impact of high-intensity interval training and moderate-intensity continuous training on resting and postexercise cardiac troponin T concentration.

    Science.gov (United States)

    Nie, Jinlei; Zhang, Haifeng; Kong, Zhaowei; George, Keith; Little, Jonathan P; Tong, Tomas K; Li, Feifei; Shi, Qingde

    2018-03-01

    What is the central question of this study? Does exercise training impact resting and postexercise cardiac troponin T (cTnT) concentration? What is the main finding and its importance? This randomized controlled intervention study demonstrated that 12 weeks of either high-intensity interval training or moderate-intensity continuous training largely abolished the exercise-induced elevation in cTnT when exercise was performed at the same absolute intensity. There was no impact of training on resting cTnT or postexercise appearance of cTnT when exercise was performed at the same relative intensity. These findings provide new information that might help clinicians with decision-making in relationship to basal and postexercise values of cTnT in individuals with different training status. We evaluated the influence of 12 weeks of high-intensity interval training [HIIT; repeated 4 min cycling at 90% of maximal oxygen uptake (V̇O2max) interspersed with 3 min rest, 200-300 kJ per session, 3 or 4 days each week] and work-equivalent moderate-intensity continuous training (MICT; continuous cycling at 60% V̇O2max) on resting cardiac troponin T (cTnT) and the appearance of exercise-induced cTnT. Forty-eight sedentary obese young women were randomly assigned to HIIT, MICT or a control group. The V̇O2max and body composition were measured before and after training. At baseline, cTnT was assessed using a high-sensitivity assay at rest and immediately, 2 and 4 h after 45 min cycling at 60% V̇O2max. After a 12 week training period, cTnT was assessed before and after 45 min cycling at the same relative and absolute intensities as before training. Training led to higher V̇O2max and lower fat mass in both HIIT and MICT groups (all P training, cTnT was significantly elevated in all three groups (by 35-118%, all P training, both resting and postexercise cTnT concentrations (same relative intensity) were similar to pretraining values. In contrast, postexercise cTnT (same

  15. High Ca2+ Influx During Traumatic Brain Injury Leads to Caspase-1-Dependent Neuroinflammation and Cell Death.

    Science.gov (United States)

    Abdul-Muneer, P M; Long, Mathew; Conte, Adriano Andrea; Santhakumar, Vijayalakshmi; Pfister, Bryan J

    2017-08-01

    We investigated the hypothesis that high Ca 2+ influx during traumatic brain injury induces the activation of the caspase-1 enzyme, which triggers neuroinflammation and cell apoptosis in a cell culture model of neuronal stretch injury and an in vivo model of fluid percussion injury (FPI). We first established that stretch injury causes a rapid increase in the intracellular Ca 2+ level, which activates interleukin-converting enzyme caspase-1. The increase in the intracellular Ca 2+ level and subsequent caspase-1 activation culminates into neuroinflammation via the maturation of IL-1β. Further, we analyzed caspase-1-mediated apoptosis by TUNEL staining and PARP western blotting. The voltage-gated sodium channel blocker, tetrodotoxin, mitigated the stretch injury-induced neuroinflammation and subsequent apoptosis by blocking Ca 2+ influx during the injury. The effect of tetrodotoxin was similar to the caspase-1 inhibitor, zYVAD-fmk, in neuronal culture. To validate the in vitro results, we demonstrated an increase in caspase-1 activity, neuroinflammation and neurodegeneration in fluid percussion-injured animals. Our data suggest that neuronal injury/traumatic brain injury (TBI) can induce a high influx of Ca 2+ to the cells that cause neuroinflammation and cell death by activating caspase-1, IL-1β, and intrinsic apoptotic pathways. We conclude that excess IL-1β production and cell death may contribute to neuronal dysfunction and cognitive impairment associated with TBI.

  16. Protein Kinase Cα and P-Type Ca2+ Channel CaV2.1 in Red Blood Cell Calcium Signalling

    Directory of Open Access Journals (Sweden)

    Lisa Wagner-Britz

    2013-06-01

    Full Text Available Background/Aims: Protein kinase Cα (PKCα is activated by an increase in cytosolic Ca2+ in red blood cells (RBCs. Previous work has suggested that PKCα directly stimulates the CaV2.1 channel, whereas other studies revealed that CaV2.1 is insensitive to activation by PKC. The aim of this study was to resolve this discrepancy. Methods: We performed experiments based on a single cell read-out of the intracellular Ca2+ concentration in terms of Fluo-4 fluorescence intensity and phosphatidylserine exposure to the external membrane leaflet. Measurement modalities included flow cytometry and live cell imaging. Results: Treatment of RBCs with phorbol 12-myristate 13-acetate (PMA led to two distinct populations of cells with an increase in intracellular Ca2+: a weak-responding and a strong-responding population. The EC50 of PMA for the number of cells with Ca2+ elevation was 2.7±1.2 µM; for phosphatidylserine exposure to the external membrane surface, it was 2.8±0.5 µM; and for RBC haemolysis, it was 2.9±0.5 µM. Using pharmacological manipulation with the CaV2.1 inhibitor ω-agatoxin TK and the broad protein kinase C inhibitor Gö6983, we are able to show that there are two independent PMA-activated Ca2+ entry processes: the first is independent of CaV2.1 and directly PKCα-activated, while the second is associated with a likely indirect activation of CaV2.1. Further studies using lysophosphatidic acid (LPA as a stimulation agent have provided additional evidence that PKCα and CaV2.1 are not directly interconnected in a signalling chain. Conclusion: Although we provide evidence for a lack of interaction between PKCα and CaV2.1 in RBCs, further studies are required to decipher the signalling relationship between LPA, PKCα and CaV2.1.

  17. Prognostic value of repeated serum CA 125 measurements in first trimester pregnancy.

    Science.gov (United States)

    Schmidt, T; Rein, D T; Foth, D; Eibach, H W; Kurbacher, C M; Mallmann, P; Römer, T

    2001-08-01

    To assess the diagnostic value of maternal CA 125 in patients with symptomatic first trimester pregnancy and to evaluate the prognostic significance of CA 125 versus beta-hCG in early pregnancies with intact fetal heartbeat, complicated by vaginal bleeding. Two prospective open-label studies with longitudinal follow-up in the second trial. Academic Department of Obstetrics and Gynecology, University of Cologne. Study 1: 168 patients presenting between gestational weeks 6 and 12 with: extrauterine pregnancy, 29; missed abortion, 50; incomplete spontaneous abortion, 38; imminent abortion, 33; and normal pregnancy (no history of endometriosis or ovarian mass), 18. Study 2: Fifty consecutive patients with vaginal bleeding during gestational weeks 6-12 all of whom having demostrable fetal heartbeat. Eighteen patients finally aborted whereas the remainder had normally continuing pregnancy until term. Study 1: Single serum determinations of CA 125 and beta-hCG were correlated with the different disorders observed. Study 2: Two sequential measurements of serum CA 125 and beta-hCG performed within a 5-7 days interval were related to the outcome of pregnancy as indicated by changes of the ultrasound presentation, miscarriage, future hospitalization, or delivery. Study 1: Patients with vaginal bleeding generally had higher median CA 125 values (38 IU/ml; range 1.3-540) compared to non-bleeding patients (17.8 IU/ml; range 1.0-157). No statistically significant differences in regard to median serum CA 125 levels between symptomatic and normal pregnancies occurred: normal pregnancy, 25.5 IU/ml (range 3.2-97); ectopic pregnancy, 26 IU/ml (range 1.3-157); missed abortion, 19.1IU/ml (range 1-242); threatened abortion, 48 IU/ml (range 5.2-540); spontaneous abortion, 40 IU/ml (range 5.4-442). Study 2: Initial CA 125 levels did not differ significantly between both groups of patients with 27/32 non-aborters and 13/18 aborters showing concentrations below 65 IU/ml. After 5-7 days, CA

  18. Synthesis and photoluminescence properties of CaSiO3:Eu3+ spheres prepared by the reverse micelles soft template

    International Nuclear Information System (INIS)

    Yang Liangzhun; Fang Min; Du Lifen; Zhang Zhaojie; Ren Liwen; Yu Xibin

    2008-01-01

    We report here the successful synthesis of CaSiO 3 :Eu 3+ spheres using the reverse micelles soft template. The influence of the calcination temperature on the shape, crystallization and photoluminescence properties of the prepared spheres was investigated by DTA-TG, XRD, IR, SEM and PL. The results showed that the temperature of crystallization (from amorphous phase to β-CaSiO 3 ) is 668 deg. C. The temperature of phase transition (from β-CaSiO 3 to α-CaSiO 3 ) is 790 deg. C. The average size of CaSiO 3 :Eu 3+ spheres calcined at 700 deg. C was about 350 nm. The radiation was dominated by the red emission peak at 613 nm and the highest emission intensity was observed when the spheres were calcined at 700 deg. C. When calcined at 800 deg. C, the spheres are almost cracked and melted down, due to the high temperature

  19. Warm-up strategy and high-intensity endurance performance in trained cyclists

    DEFF Research Database (Denmark)

    Christensen, Peter Møller; Bangsbo, Jens

    2015-01-01

    ; means±SD) performed three warm-up strategies lasting 20 min before a 4-min maximal performance test (PT). Strategies consisted of moderate intensity exercise (50%iPPO) followed by 6 min of recovery (MOD6) or progressive-high intensity exercise (10-100%iPPO and 2x20-s sprints) followed by recovery for 6...

  20. STATUS REPORT ON DEVELOPMENT OF A HIGH-SPEED HIGH-INTENSITY MOLECULAR BEAM

    Energy Technology Data Exchange (ETDEWEB)

    Knuth, Eldon L.

    1963-07-15

    Status of a high-speed high-intensity molecular beam under development is described. Bases for designs of the several components are presented. Using an arc-heated source and a hypersonic jet, molecular energies exceeding 1 ev and beam intensities of the order of 10/sup 16/ molecules/ cm/sup 2/ sec are anticipated. A two-disk beam chopper and speed selector provides a means for analyzing the speed distribution in the generated beam, for chopping the beam into bursts of nearly monoenergetic molecules suitable for scattering studies using the time-of-flight technique, and for modulating the beam in order to facilitate detection. A through-flow ionization detector possesses the versatility required for scattering studies using the time-of-flight technique. A sorption pump and a turbo pump serve as central components of alternative pumping systems for the collimating chamber. Using the arc-heated source, the converging nozzle, the conduction-radiation-cooled skimmer, the turbo pump (turning at 3400 rpm), the chopperselector (acting only as a chopper), and the detector, an arc-heated beam is generated and detected. (auth)

  1. Isotope shift of 40,42,44,48Ca in the 4s 2S1/2 → 4p 2P3/2 transition

    Science.gov (United States)

    Gorges, C.; Blaum, K.; Frömmgen, N.; Geppert, Ch; Hammen, M.; Kaufmann, S.; Krämer, J.; Krieger, A.; Neugart, R.; Sánchez, R.; Nörtershäuser, W.

    2015-12-01

    We report on improved isotope shift measurements of the isotopes {}{40,42,{44,48}}Ca in the 4{{s}}{ }2{{{S}}}1/2\\to 4{{p}}{ }2{{{P}}}3/2 (D2) transition using collinear laser spectroscopy. Accurately known isotope shifts in the 4{{s}}{ }2{{{S}}}1/2\\to 4{{p}}{ }2{{{P}}}1/2(D1) transition were used to calibrate the ion beam energy with an uncertainty of {{Δ }}U≈ +/- 0.25 {{V}}. The accuracy in the D2 transition was improved by a factor of 5-10. A King-plot analysis of the two transitions revealed that the field shift factor in the D2 line is about 1.8(13)% larger than in the D1 transition which is ascribed to relativistic contributions of the 4{{{p}}}1/2 wave function.

  2. Applications of High Intensity Proton Accelerators

    Science.gov (United States)

    Raja, Rajendran; Mishra, Shekhar

    2010-06-01

    Superconducting radiofrequency linac development at Fermilab / S. D. Holmes -- Rare muon decay experiments / Y. Kuno -- Rare kaon decays / D. Bryman -- Muon collider / R. B. Palmer -- Neutrino factories / S. Geer -- ADS and its potential / J.-P. Revol -- ADS history in the USA / R. L. Sheffield and E. J. Pitcher -- Accelerator driven transmutation of waste: high power accelerator for the European ADS demonstrator / J. L. Biarrotte and T. Junquera -- Myrrha, technology development for the realisation of ADS in EU: current status & prospects for realisation / R. Fernandez ... [et al.] -- High intensity proton beam production with cyclotrons / J. Grillenberger and M. Seidel -- FFAG for high intensity proton accelerator / Y. Mori -- Kaon yields for 2 to 8 GeV proton beams / K. K. Gudima, N. V. Mokhov and S. I. Striganov -- Pion yield studies for proton driver beams of 2-8 GeV kinetic energy for stopped muon and low-energy muon decay experiments / S. I. Striganov -- J-Parc accelerator status and future plans / H. Kobayashi -- Simulation and verification of DPA in materials / N. V. Mokhov, I. L. Rakhno and S. I. Striganov -- Performance and operational experience of the CNGS facility / E. Gschwendtner -- Particle physics enabled with super-conducting RF technology - summary of working group 1 / D. Jaffe and R. Tschirhart -- Proton beam requirements for a neutrino factory and muon collider / M. S. Zisman -- Proton bunching options / R. B. Palmer -- CW SRF H linac as a proton driver for muon colliders and neutrino factories / M. Popovic, C. M. Ankenbrandt and R. P. Johnson -- Rapid cycling synchrotron option for Project X / W. Chou -- Linac-based proton driver for a neutrino factory / R. Garoby ... [et al.] -- Pion production for neutrino factories and muon colliders / N. V. Mokhov ... [et al.] -- Proton bunch compression strategies / V. Lebedev -- Accelerator test facility for muon collider and neutrino factory R&D / V. Shiltsev -- The superconducting RF linac for muon

  3. Nanosilica supported CaO: A regenerable and mechanically hard CO2 sorbent at Ca-looping conditions

    International Nuclear Information System (INIS)

    Sanchez-Jimenez, P.E.; Perez-Maqueda, L.A.; Valverde, J.M.

    2014-01-01

    Highlights: • A synthetic CO 2 sorbent is prepared by impregnation of calcium nitrate on a nanosilica matrix. • Sintering of the nascent CaO in the calcination stage of carbonation/calcination cycles is hindered. • CaO conversion reaches a stable value well above the residual conversion of natural limestone. • Particle fragmentation as caused by ultrasonic irradiation in a liquid dispersion is hindered. - Abstract: This work presents a CO 2 sorbent that may be synthesized from low-cost and widely available materials following a simple method basically consisting of impregnation of a nanostructured silica support with a saturated solution of calcium nitrate. In a first impregnation stage, the use of a stoichiometric CaO/SiO 2 ratio serves to produce a calcium silicate matrix after calcination. This calcium silicate matrix acts as a thermally stable and mechanically hard support for CaO deposited on it by further impregnation. The CaO-impregnated sorbent exhibits a stable CaO conversion at Ca-looping conditions whose value depends on the CaO wt% deposited on the calcium silicate matrix, which can be increased by successive reimpregnations. A 10 wt% CaO impregnated sorbent reaches a stable conversion above 0.6 whereas the stable conversion of a 30 wt% CaO impregnated sorbent is around 0.3, which is much larger than the residual conversion of CaO derived from natural limestone (between 0.07 and 0.08). Moreover, particle size distribution measurements of samples predispersed in a liquid and subjected to high energy ultrasonic waves indicate that the CaO-impregnated sorbent has a relatively high mechanical strength as compared to limestone derived CaO

  4. Linear optical properties of Ca4EuO(BO3)3 and Eu3+ : Ca4GdO(BO3)3 crystals

    International Nuclear Information System (INIS)

    Antic-Fidancev, E.; Lemaitre-Blaise, M.; Porcher, P.; Caramanian, A.; Aka, G.

    1998-01-01

    Full text: The title compounds are now intensively studied due to their quadratic nonlinear properties in view of applications, e.g. high power laser frequency conversion. Rare earth calcium oxoborates, Ca 4 REO(BO 3 ) 3 , constitute an isostructural family along the rare earth series with RE = La - Lu, Y included. These compounds crystallize in the monoclinic biaxial crystal system with Cm (N 8) space group. They are isostructural to the calcium fluoroborate Ca 5 (BO 3 ) 3 F which is related to the fluoroapatite structure Ca 5 (PO 4 ) 3 F. The rare earth ions are located in the distorted octahedron with C s point site symmetry in the mirror plane. Two types of distorted octahedral sites exist for calcium ions. The existence of some disorder between calcium and rare earth atoms is suspected from the structural analysis. Good optical quality crystals of europium (or gadolinium) oxoborate, EuCOB (GdCOB) have been grown from the stoichiometric melt by the Czochralski pulling method. From the luminescence of the Eu 3+ doped gadolinium or in the europium stoichiometric compound very complex emission spectra have been obtained. It principally depends on the preparation method of studied samples: i) for a monocrystalline sample, a single phase with a single site is observed; ii) for a polycrystalline sample complex feature occurs. It is probably due to an expanded disorder between calcium and rare earth atoms. Practically, there is one principal site corresponding to the low symmetry site of the rare earth as expected from the structural investigation. Other minor sites are attributed to the local distortion created around the active rare earth ion. The intensity of the emission lines of Eu 3+ used as a local structural probe related to these minor sites increases when the gadolinium in Ca 4 GdO(BO 0 ) 3 is substituted by lanthanum or yttrium ions. It seems therefore evident that the synthesis of these rare earth calcium oxoborates must be realised carefully. The crystal

  5. Development of apparatus for high-intensity beam lines at the KEK-PS new experimental hall

    International Nuclear Information System (INIS)

    Yamanoi, Yutaka; Tanaka, Kazuhiro; Minakawa, Michifumi

    1992-01-01

    The new counter experimental hall was constructed at the KEK 12 GeV Proton Synchrotron (the KEK-PS) in order to handle high-intensity primary proton beams of up to 1 x 10 13 pps (protons per second), which is one order of magnitude greater than the present beam intensity of the KEK-PS, 1 x 10 12 pps. New technologies for handling high-intensity beams have, then, been developed and employed in the new hall construction. A part of our R/D work on handling high intensity beam is briefly reported. (author)

  6. Psychophysiological effects of music on acute recovery from high-intensity interval training.

    Science.gov (United States)

    Jones, Leighton; Tiller, Nicholas B; Karageorghis, Costas I

    2017-03-01

    Numerous studies have examined the multifarious effects of music applied during exercise but few have assessed the efficacy of music as an aid to recovery. Music might facilitate physiological recovery via the entrainment of respiratory rhythms with music tempo. High-intensity exercise training is not typically associated with positive affective responses, and thus ways of assuaging negative affect warrant further exploration. This study assessed the psychophysiological effects of music on acute recovery and prevalence of entrainment in between bouts of high-intensity exercise. Thirteen male runners (M age =20.2±1.9years; BMI=21.7±1.7; V̇O 2 max=61.6±6.1mL·kg·min -1 ) completed three exercise sessions comprising 5×5-min bouts of high-intensity intervals interspersed with 3-min periods of passive recovery. During recovery, participants were administered positively-valenced music of a slow-tempo (55-65bpm), fast-tempo (125-135bpm), or a no-music control. A range of measures including affective responses, RPE, cardiorespiratory indices (gas exchange and pulmonary ventilation), and music tempo-respiratory entrainment were recorded during exercise and recovery. Fast-tempo, positively-valenced music resulted in higher Feeling Scale scores throughout recovery periods (pmusic-moderated differences in cardiorespiratory responses. In conclusion, fast-tempo, positively-valenced music applied during recovery periods engenders a more pleasant experience. However, there is limited evidence that music expedites cardiorespiratory recovery in between bouts of high-intensity exercise. These findings have implications for athletic training strategies and individuals seeking to make high-intensity exercise sessions more pleasant. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Correlation between TL and OSL properties of CaF2:N

    International Nuclear Information System (INIS)

    Polymeris, George S.; Kitis, George; Tsirliganis, Nestor C.

    2006-01-01

    Natural CaF 2 is very well known thermoluminescent (TL) material, since it has been extensively used as a dosimeter. Its basic advantage is the exhibited high TL sensitivity. In the present work, the optically stimulated luminescence (OSL) sensitivity of this material was studied by exposing it to environmental radiation for time intervals of few hours up to a few days, and was found to be very high. By analyzing the TL glow curves and the OSL decay curves into their individual glow-peaks and components respectively, a relation between specific glow-peaks and OSL components was established. An intense thermal transfer effect occurring during optical stimulation at high temperature was observed and an explanation is offered according to existing models

  8. High-intensity exercise interventions in cancer survivors: a systematic review exploring the impact on health outcomes.

    Science.gov (United States)

    Toohey, Kellie; Pumpa, Kate; McKune, Andrew; Cooke, Julie; Semple, Stuart

    2018-01-01

    There is an increasing body of evidence underpinning high-intensity exercise as an effective and time-efficient intervention for improving health in cancer survivors. The aim of this study was to, (1) evaluate the efficacy and (2) the safety of high-intensity exercise interventions in improving selected health outcomes in cancer survivors. Design Systematic review. Data sources Google Scholar and EBSCO, CINAHL Plus, Computers and Applied Sciences Complete, Health Source-Consumer Edition, Health Source: Nursing/Academic Edition, MEDLINE, Web of Science and SPORTDiscuss from inception up until August 2017. Eligibility criteria Randomized controlled trials of high-intensity exercise interventions in cancer survivors (all cancer types) with health-related outcome measures. The guidelines adopted for this review were the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA). The search returned 447 articles, of which nine articles (n = 531 participants mean, age 58 ± 9.5 years) met the eligibility criteria. Exercise interventions of between 4 and 18 weeks consisting of high-intensity interval bouts of up to 4-min were compared with a continuous moderate intensity (CMIT) intervention or a control group. High-intensity exercise interventions elicited significant improvements in VO 2 max, strength, body mass, body fat and hip and waist circumference compared with CMIT and/or control groups. The studies reviewed showed low risk in participating in supervised high-intensity exercise interventions. Mixed mode high-intensity interventions which included both aerobic and resistance exercises were most effective improving the aerobic fitness levels of cancer survivors by 12.45-21.35%, from baseline to post-intervention. High-intensity exercise interventions improved physical and physiological health-related outcome measures such as cardiovascular fitness and strength in cancer survivors. Given that high-intensity exercise sessions require a

  9. Highly segmented CVD diamond detectors and high-resolution momentum measurements in knockout reactions; Hochsegmentierte CVD Diamant Detektoren und hochaufloesende Impulsmessungen in Knockout Reaktionen

    Energy Technology Data Exchange (ETDEWEB)

    Schwertel, Sabine

    2009-11-26

    In recent years knockout reactions have proven to be important tools for investigations of the structure of light exotic nuclei. In spring 2006 an experiment was performed with the fragment separator at GSI in Darmstadt to extend this method to medium-mass nuclei with energies of about 400 AMeV. An experiment with a stable and well-known {sup 48}Ca primary beam was performed as a reference. The FRS was set for the reaction {sup 56}Ti{yields}{sup 55}Ti. Because of the high acceptance of the FRS, mother and daughter nuclei of one-neutron knockout reactions in the Sc isotopes {sup 51,52,53,54,55}Sc were also transported with high efficiency. These are investigated in the first part of this thesis. Inclusive cross sections of 77(10) mbarn for one-neutron knockout from {sup 48}Ca and 78(12) mbarn, 99(15) mbarn, 101(15) mbarn, 113(17) mbarn and 72(14) mbarn for knockout from {sup 51,52,53,54,55}Sc, respectively, were measured for the first time. For the Sc isotopes the reduction factors are close to 1. For the one-neutron knockout reactions in {sup 48}Ca and the Sc isotopes, respectively, the momentum distributions could be measured with a relative resolution of 0.17-0.27 %. From the momentum distributions spectroscopic factors of the involved orbitals could be extracted. In the future, further knockout experiments should be performed using the R{sup 3}B setup at FAIR. The available beam intensity will be up to four orders of magnitude higher. As the beam has to be tracked from the dispersive plane of the Super-FRS up to the R{sup 3}B target, radiation hard detectors are needed. In the framework of this thesis extensive measurements were performed at the tandem accelerator in Munich with numerous small (10 x 10 mm{sup 2}) test detectors. Samples using new manufacturing methods were characterized. A dose of some 10{sup 11} ions/mm{sup 2} was determined as a limit for the exposure of the material with heavy ions of high ionisation density. It could be shown that even

  10. Synthesis and luminescent properties of CaCO3:Eu3+@SiO2 phosphors with core-shell structure

    Science.gov (United States)

    Liu, Min; Kang, Ming; Chen, Kexu; Mou, Yongren; Sun, Rong

    2018-03-01

    Integrating the processes of preparation of CaCO3:Eu3+ and its surface-coating, core-shell structured CaCO3:Eu3+@SiO2 phosphors with red emission were synthesized by the carbonation method and surface precipitation procedure using sodium silicate as silica source. The phase structure, thermal stability, morphology and luminescent property of the as-synthesized samples were characterized by X-ray diffraction, Fourier transform infrared spectrum, thermal analysis, field-emission scanning electron microscopy, transmission electron microscope and photoluminescence spectra. The experimental results show that Eu3+ ions as the luminescence center are divided into two types: one is at the surface of the CaCO3 and the other inhabits the site of Ca2+. For CaCO3:Eu3+@SiO2 phosphors, the SiO2 layers are continuously coated on the surface of CaCO3:Eu3+ and show a typical core-shell structure. After coated with SiO2 layer, the luminous intensity and the compatibility with the rubber matrix increase greatly. Additionally, the luminous intensity increases with the increasing of Eu3+ ions concentration in CaCO3 core and concentration quenching occurs when Eu3+ ions concentration exceeds 7.0 mol%, while it is 5.0 mol% for CaCO3:Eu3+ phosphors. Therefore, preparation of CaCO3:Eu3+@SiO2 phosphors can not only simplify the experimental process through integrating the preparation of CaCO3:Eu3+ and SiO2 layer, but also effectively increase the luminous intensities of CaCO3:Eu3+ phosphors. The as-obtained phosphors may have potential applications in the fields of optical materials and functional polymer composite materials, such as plastics and rubbers.

  11. Liquid lithium target as a high intensity, high energy neutron source

    Science.gov (United States)

    Parkin, Don M.; Dudey, Norman D.

    1976-01-01

    This invention provides a target jet for charged particles. In one embodiment the charged particles are high energy deuterons that bombard the target jet to produce high intensity, high energy neutrons. To this end, deuterons in a vacuum container bombard an endlessly circulating, free-falling, sheet-shaped, copiously flowing, liquid lithium jet that gushes by gravity from a rectangular cross-section vent on the inside of the container means to form a moving web in contact with the inside wall of the vacuum container. The neutrons are produced via break-up of the beam in the target by stripping, spallation and compound nuclear reactions in which the projectiles (deuterons) interact with the target (Li) to produce excited nuclei, which then "boil off" or evaporate a neutron.

  12. Liquid lithium target as a high intensity, high energy neutron source

    International Nuclear Information System (INIS)

    Parkin, D.M.; Dudey, N.D.

    1976-01-01

    The invention described provides a target jet for charged particles. In one embodiment the charged particles are high energy deuterons that bombard the target jet to produce high intensity, high energy neutrons. To this end, deuterons in a vacuum container bombard an endlessly circulating, free-falling, sheet-shaped, copiously flowing, liquid lithium jet that gushes by gravity from a rectangular cross-section vent on the inside of the container means to form a moving web in contact with the inside wall of the vacuum container. The neutrons are produced via break-up of the beam in the target by stripping, spallation and compound nuclear reactions in which the projectiles (deuterons) interact with the target (Li) to produce excited nuclei, which then ''boil off'' or evaporate a neutron

  13. High-intensity positron microprobe at the Thomas Jefferson National Accelerator Facility

    International Nuclear Information System (INIS)

    Golge, S.; Vlahovic, B.; Wojtsekhowski, B.

    2014-01-01

    We present a conceptual design for a novel continuous wave electron-linac based high-intensity high-brightness slow-positron production source with a projected intensity on the order of 10 10  e + /s. Reaching this intensity in our design relies on the transport of positrons (T + below 600 keV) from the electron-positron pair production converter target to a low-radiation and low-temperature area for moderation in a high-efficiency cryogenic rare gas moderator, solid Ne. This design progressed through Monte Carlo optimizations of: electron/positron beam energies and converter target thickness, transport of the e + beam from the converter to the moderator, extraction of the e + beam from the magnetic channel, a synchronized raster system, and moderator efficiency calculations. For the extraction of e + from the magnetic channel, a magnetic field terminator plug prototype has been built and experimental results on the effectiveness of the prototype are presented. The dissipation of the heat away from the converter target and radiation protection measures are also discussed.

  14. High-intensity positron microprobe at the Thomas Jefferson National Accelerator Facility

    Energy Technology Data Exchange (ETDEWEB)

    Golge, S., E-mail: serkan.golge@nasa.gov; Vlahovic, B. [North Carolina Central University, Durham, North Carolina 27707 (United States); Wojtsekhowski, B. [Jefferson Laboratory, 12000 Jefferson Ave., Newport News, Virginia 23606 (United States)

    2014-06-21

    We present a conceptual design for a novel continuous wave electron-linac based high-intensity high-brightness slow-positron production source with a projected intensity on the order of 10{sup 10 }e{sup +}/s. Reaching this intensity in our design relies on the transport of positrons (T{sub +} below 600 keV) from the electron-positron pair production converter target to a low-radiation and low-temperature area for moderation in a high-efficiency cryogenic rare gas moderator, solid Ne. This design progressed through Monte Carlo optimizations of: electron/positron beam energies and converter target thickness, transport of the e{sup +} beam from the converter to the moderator, extraction of the e{sup +} beam from the magnetic channel, a synchronized raster system, and moderator efficiency calculations. For the extraction of e{sup +} from the magnetic channel, a magnetic field terminator plug prototype has been built and experimental results on the effectiveness of the prototype are presented. The dissipation of the heat away from the converter target and radiation protection measures are also discussed.

  15. Oxidative stress does not influence local sweat rate during high-intensity exercise.

    Science.gov (United States)

    Meade, Robert D; Fujii, Naoto; Poirier, Martin P; Boulay, Pierre; Sigal, Ronald J; Kenny, Glen P

    2018-02-01

    What is the central question of this study? We evaluated whether oxidative stress attenuates the contribution of nitric oxide to sweating during high-intensity exercise. What is the main finding and its importance? In contrast to our previous report of an oxidative stress-mediated reduction in nitric oxide-dependent cutaneous vasodilatation in this cohort during intense exercise, we demonstrated no influence of local ascorbate administration on the sweating response during moderate- (∼51% peak oxygen uptake) or high-intensity exercise (∼72% peak oxygen uptake). These new findings provide important mechanistic insight into how exercise-induced oxidative stress impacts sudomotor activity. Nitric oxide (NO)-dependent sweating is diminished during high- but not moderate-intensity exercise. We evaluated whether this impairment stems from increased oxidative stress during high-intensity exercise. On two separate days, 11 young (24 ± 4 years) men cycled in the heat (35°C) at a moderate [500 W; 52 ± 6% peak oxygen uptake (V̇O2 peak )] or high (700 W; 71 ± 5% V̇O2 peak ) rate of metabolic heat production. Each session included two 30 min exercise bouts separated by a 20 min recovery period. Local sweat rate was monitored at four forearm skin sites continuously perfused via intradermal microdialysis with the following: (i) lactated Ringer solution (Control); (ii) 10 mm ascorbate (Ascorbate; non-selective antioxidant); (iii) 10 mm N G -nitro-l-arginine methyl ester (l-NAME; NO synthase inhibitor); or (iv) 10 mm ascorbate plus 10 mm l-NAME (Ascorbate + l-NAME). During moderate exercise, sweat rate was attenuated at the l-NAME and Ascorbate + l-NAME sites (both ∼1.0 mg min -1  cm -2 ; all P < 0.05) but not at the Ascorbate site (∼1.1 mg min -1  cm -2 ; both P ≥ 0.28) in comparison to the Control site (∼1.1 mg min -1  cm -2 ). However, no differences were observed between treatment sites (∼1.4 mg min -1  cm -2 ; P = 0

  16. The optimal period of Ca-EDTA treatment for parthenogenetic activation of porcine oocytes during maturation culture

    OpenAIRE

    MORITA, Yasuhiro; TANIGUCHI, Masayasu; TANIHARA, Fuminori; ITO, Aya; NAMULA, Zhao; DO, Lanh Thi Kim; TAKAGI, Mitsuhiro; TAKEMOTO, Tatsuya; OTOI, Takeshige

    2016-01-01

    The changes triggered by sperm-induced activation of oocytes, which are required for normal oocyte development, can be mediated by other agents, thereby inducing the parthenogenesis. In this study, we exposed porcine oocytes to 1 mM Ca-EDTA, a metal-ion chelator, at various intervals during 48 hr of in vitro maturation to determine the optimum period of Ca-EDTA treatment for parthenogenetic activation. When the oocytes were cultured with or without Ca-EDTA from 36 hr (post-12), 24 hr (post-24...

  17. Dose rate laser simulation tests adequacy: Shadowing and high intensity effects analysis

    International Nuclear Information System (INIS)

    Nikiforov, A.Y.; Skorobogatov, P.K.

    1996-01-01

    The adequacy of laser based simulation of the flash X-ray effects in microcircuits may be corrupted mainly due to laser radiation shadowing by the metallization and the non-linear absorption in a high intensity range. The numerical joint solution of the optical equations and the fundamental system of equations in a two-dimensional approximation were performed to adjust the application range of laser simulation. As a result the equivalent dose rate to laser intensity correspondence was established taking into account the shadowing as well as the high intensity effects. The simulation adequacy was verified in the range up to 4·10 11 rad(Si)/s with the comparative laser test of a specially designed test structure

  18. Radiation control in the intensive care unit for high intensity iridium-192 brain implants

    International Nuclear Information System (INIS)

    Sewchand, W.; Drzymala, R.E.; Amin, P.P.; Salcman, M.; Salazar, O.M.

    1987-01-01

    A bedside lead cubicle was designed to minimize the radiation exposure of intensive care unit staff during routine interstitial brain irradiation by removable, high intensity iridium-192. The cubicle shields the patient without restricting intensive care routines. The design specifications were confirmed by exposure measurements around the shield with an implanted anthropomorphic phantom simulating the patient situation. The cubicle reduces the exposure rate around an implant patient by as much as 90%, with the exposure level not exceeding 0.1 mR/hour/mg of radium-equivalent 192 Ir. Evaluation of data accumulated for the past 3 years has shown that the exposure levels of individual attending nurses are 0.12 to 0.36 mR/mg of radium-equivalent 192 Ir per 12-hour shift. The corresponding range for entire nursing teams varies between 0.18 and 0.26. A radiation control index (exposure per mg of radium-equivalent 192 Ir per nurse-hour) is thus defined for individual nurses and nursing teams; this index is a significant guide to the planning of nurse rotations for brain implant patients with various 192 Ir loads. The bedside shield reduces exposure from 192 Ir implants by a factor of about 20, as expected, and the exposure from the lower energy radioisotope iodine-125 is barely detectable

  19. High-intensity interval exercise and cerebrovascular health: curiosity, cause, and consequence

    OpenAIRE

    Lucas, Samuel J E; Cotter, James D; Brassard, Patrice; Bailey, Damian M

    2015-01-01

    Exercise is a uniquely effective and pluripotent medicine against several noncommunicable diseases of westernised lifestyles, including protection against neurodegenerative disorders. High-intensity interval exercise training (HIT) is emerging as an effective alternative to current health-related exercise guidelines. Compared with traditional moderate-intensity continuous exercise training, HIT confers equivalent if not indeed superior metabolic, cardiac, and systemic vascular adaptation. Con...

  20. Electric dipole strength and dipole polarizability in 48Ca within a fully self-consistent second random–phase approximation

    Directory of Open Access Journals (Sweden)

    D. Gambacurta

    2018-02-01

    Full Text Available The second random–phase–approximation model corrected by a subtraction procedure designed to cure double counting, instabilities, and ultraviolet divergences, is employed for the first time to analyze the dipole strength and polarizability in 48Ca. All the terms of the residual interaction are included, leading to a fully self-consistent scheme. Results are illustrated with two Skyrme parametrizations, SGII and SLy4. Those obtained with the SGII interaction are particularly satisfactory. In this case, the low-lying strength below the neutron threshold is well reproduced and the giant dipole resonance is described in a very satisfactory way especially in its spreading and fragmentation. Spreading and fragmentation are produced in a natural way within such a theoretical model by the coupling of 1 particle-1 hole and 2 particle-2 hole configurations. Owing to this feature, we may provide for the electric polarizability as a function of the excitation energy a curve with a similar slope around the centroid energy of the giant resonance compared to the corresponding experimental results. This represents a considerable improvement with respect to previous theoretical predictions obtained with the random–phase approximation or with several ab-initio models. In such cases, the spreading width of the excitation cannot be reproduced and the polarizability as a function of the excitation energy displays a stiff increase around the predicted centroid energy of the giant resonance.

  1. Electric dipole strength and dipole polarizability in 48Ca within a fully self-consistent second random-phase approximation

    Science.gov (United States)

    Gambacurta, D.; Grasso, M.; Vasseur, O.

    2018-02-01

    The second random-phase-approximation model corrected by a subtraction procedure designed to cure double counting, instabilities, and ultraviolet divergences, is employed for the first time to analyze the dipole strength and polarizability in 48Ca. All the terms of the residual interaction are included, leading to a fully self-consistent scheme. Results are illustrated with two Skyrme parametrizations, SGII and SLy4. Those obtained with the SGII interaction are particularly satisfactory. In this case, the low-lying strength below the neutron threshold is well reproduced and the giant dipole resonance is described in a very satisfactory way especially in its spreading and fragmentation. Spreading and fragmentation are produced in a natural way within such a theoretical model by the coupling of 1 particle-1 hole and 2 particle-2 hole configurations. Owing to this feature, we may provide for the electric polarizability as a function of the excitation energy a curve with a similar slope around the centroid energy of the giant resonance compared to the corresponding experimental results. This represents a considerable improvement with respect to previous theoretical predictions obtained with the random-phase approximation or with several ab-initio models. In such cases, the spreading width of the excitation cannot be reproduced and the polarizability as a function of the excitation energy displays a stiff increase around the predicted centroid energy of the giant resonance.

  2. Afterglow properties of CaF2:Tm nanoparticles and its potential application in photodynamic therapy

    International Nuclear Information System (INIS)

    Zahedifar, M.; Sadeghi, E.; Shanei, M.M.; Sazgarnia, A.; Mehrabi, M.

    2016-01-01

    CaF 2 :Tm nanoparticles (NPs) were synthesized by the hydrothermal method. Intense afterglow emission with long life time was found for the produced NPs, so its applicability in photodynamic therapy was investigated. Since the wavelength of the afterglow emission of the NPs fairly matches with the absorption band of the PpIX sensitizer, especially in the red region, the Cystein mediator was used to bond NPs with the PpIX sensitizer. The CaF 2 :Tm NPs conjugated with PpIX was exposed to X-ray and by using the Antracene as detector, the production of the singlet oxygen was verified. Therefore, the produced NPs are recommended as a source of energy that improves photodynamic therapy beyond its current limitations. - Highlights: • Intense afterglow emission found for the synthesized CaF 2 :Tm nanoparticles. • CaF 2 :Tm emission band fairly matched with PpIX sensitizer's absorption band. • CaF 2 :Tm conjugated with the sensitized is a good candidate for photodynamic therapy. • The application of nanoparticles in producing singlet oxygen was verified.

  3. High intensity proton linac activities at Los Alamos

    International Nuclear Information System (INIS)

    Rusnak, B.; Chan, K.C.; Campbell, B.

    1998-01-01

    High-current proton linear accelerators offer an attractive alternative for generating the intense neutron fluxes needed for transmutations technologies, tritium production and neutron science. To achieve the fluxes required for tritium production, a 100-mA, 1700-MeV cw proton accelerator is being designed that uses superconducting cavities for the high-energy portion of the linac, from 211 to 1,700 MeV. The development work supporting the linac design effort is focused on three areas: superconducting cavity performance for medium-beta cavities at 700 MHz, high power rf coupler development, and cryomodule design. An overview of the progress in these three areas is presented

  4. HELIOS: A high intensity chopper spectrometer at LANSCE

    International Nuclear Information System (INIS)

    Mason, T.E.; Broholm, C.; Fultz, B.

    1998-01-01

    A proposal to construct a high intensity chopper spectrometer at LANSCE as part of the SPSS upgrade project is discussed. HELIOS will be optimized for science requiring high sensitivity neutron spectroscopy. This includes studies of phonon density of states in small polycrystalline samples, magnetic excitations in quantum magnets and highly correlated electron systems, as well as parametric studies (as a function of pressure, temperature, or magnetic field) of S(Q,ω). By employing a compact design together with the use of supermirror guide in the incident flight path the neutron flux at HELIOS will be significantly higher than any other comparable instrument now operating

  5. HELIOS: A high intensity chopper spectrometer at LANSCE

    Energy Technology Data Exchange (ETDEWEB)

    Mason, T.E. [Oak Ridge National Lab., TN (United States); Broholm, C. [Johns Hopkins Univ., Baltimore, MD (United States). Dept. of Physics and Astronomy; Fultz, B. [California Inst. of Tech., Pasadena, CA (United States). Dept. of Materials Science] [and others

    1998-12-31

    A proposal to construct a high intensity chopper spectrometer at LANSCE as part of the SPSS upgrade project is discussed. HELIOS will be optimized for science requiring high sensitivity neutron spectroscopy. This includes studies of phonon density of states in small polycrystalline samples, magnetic excitations in quantum magnets and highly correlated electron systems, as well as parametric studies (as a function of pressure, temperature, or magnetic field) of S(Q,{omega}). By employing a compact design together with the use of supermirror guide in the incident flight path the neutron flux at HELIOS will be significantly higher than any other comparable instrument now operating.

  6. Do alcohol use reasons and contexts differentiate adolescent high-intensity drinking? Data from U.S. high school seniors, 2005-2016.

    Science.gov (United States)

    Terry-McElrath, Yvonne M; Stern, Stephanie A; Patrick, Megan E

    2017-11-01

    The purpose of this study was to examine associations between (a) self-reported reasons for and contexts of alcohol use and (b) high-intensity drinking (i.e., having 10+ drinks in a row in the past 2 weeks) among national samples of U.S. 12th grade students. Data were obtained from 16,902 students who reported any past 12-month alcohol use from nationally representative annual 12th grade student samples from 2005-2016. When asked about drinking behavior during the past 2 weeks, 72% reported consuming less than 5 drinks at most during 1 drinking occasion; 14% reported 5-9 drinks, 7% reported 10-14 drinks, and 7% reported 15+ drinks. Adolescent drinkers in all categories (good time" as the most prevalent reason for alcohol use, and "at a party" as the most prevalent context of alcohol use. However, high-intensity drinking was particularly likely among adolescents drinking for coping, compulsive use, and drug effect reasons, as well as those who enjoyed the taste. Having 15+ drinks (vs. 10-14 drinks) was particularly associated with compulsive use and enjoying the taste. The relative risk of any high-intensity drinking, and of higher levels of high-intensity drinking involvement, increased with the total number of reasons and contexts endorsed. Alcohol appears to serve a larger number of functions for high-intensity drinking adolescents than non-high-intensity drinking youth. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  7. Effects of high-intensity training on cardiovascular risk factors in pre- and postmenopausal women

    DEFF Research Database (Denmark)

    Mandrup Jensen, Camilla Maria; Egelund, Jon; Nyberg, Michael Permin

    2017-01-01

    and cardiovascular disease in late pre- and early postmenopausal women, matched by age and body composition, and investigate the effect of high-intensity training. METHODS: A 3-month high-intensity aerobic training intervention, involving healthy, non-obese, late pre- (n=40) and early postmenopausal (n=39) women....... A three month intervention of high-intensity aerobic training reduces risk factors for type 2 diabetes and cardiovascular disease to a similar extent in late pre- and early postmenopausal women....... the postmenopausal women had higher total cholesterol (ptraining intervention reduced body weight (p

  8. Ba{sub 2.2}Ca{sub 0.8}Mg{sub 4}F{sub 14}, a new ''solid solution stabilized'' matrix for an intense blue phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Kubel, F.; Pantazi, M. [TU Vienna, Inst. of Chemical Technologies and Analytics, Getreidemarkt 9, 164-SC, 1060 Vienna (Austria); Hagemann, H. [Departement de Chimie Physique, Universite de Geneve, 30, quai E.Ansermet, 1211 Geneva 4 (Switzerland)

    2011-09-15

    Barium calcium magnesium fluoride (Ba{sub 2}(Ba{sub x}Ca{sub 1-x})Mg{sub 4}F{sub 14}, x=0.19-0.26) has been synthesized at 850 C from precursors prepared by the solution precipitation method. Single crystals with composition of Ba{sub 2.200(2)}Ca{sub 0.800(2)}Mg{sub 4}F{sub 14}were obtained after prolonged heating. Lattice parameters from single crystal data are a = 12.4203(8) and c = 7.4365(5) A [tetragonal, space group P4{sub 2}/mnm (No. 136)]. They increase with increasing barium concentration within a given stability window. The structure is built of a network of MgF{sub 6} octahedra forming a pyrochlore related channel system and isolated fluorine ions. Within the channels, heavy alkaline earth ions are located. The wide channel is filled with off-center positioned barium ions. The channel with a narrow cross section hosts both ions, Ca{sup 2+}and Ba{sup 2+}. The structure is isotypic with Pb{sub 3}Nb{sub 4}O{sub 12}F{sub 2} but has a different coordination around Ba/Ca and Pb, respectively. Doped with {proportional_to}1% Eu(II), the compound shows intense blue luminescence under UV activation. (copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  9. Moderate and high intensity pulsed electric fields

    OpenAIRE

    Timmermans, Rian Adriana Hendrika

    2018-01-01

    Pulsed Electric Field (PEF) processing has gained a lot of interest the last decades as mild processing technology as alternative to thermal pasteurisation, and is suitable for preservation of liquid food products such as fruit juices. PEF conditions typically applied at industrial scale for pasteurisation are high intensity pulsed electric fields aiming for minimal heat load, with an electric field strength (E) in the range of 15 − 20 kV/cm and pulse width (τ) between 2 − 20 μs. Alternativel...

  10. Sol–gel synthesis and photoluminescence of CaTi1–x Zrx O3: Pr 3 ...

    Indian Academy of Sciences (India)

    The strongest red excitation obtained from CaTi1–ZrO3 : Pr3+ ( = 4/300) and CaTi1–ZrO3 : Pr3+ ( = 5/300) possesses the strongest emission at 610 nm, similar to the intensities of Ca(Ti1–Zr)O3 : Pr3+ ( = 3/300, 4/300, 6/300), which may be corresponded to the cell parameters of CaTi1–ZrO3 : Pr3+.

  11. The joint project for high-intensity proton accelerators

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-08-01

    Japan Atomic Energy Research Institute (JAERI) and the High Energy Accelerator Research Organization (KEK) agreed to promote the joint project integrating both the Neutron Science Project (NSP) of JAERI and the Japan Hadron Facility Project (JHF) of KEK for comprehensive studies on basic science and technology using high-intensity proton accelerator. This document describes the joint proposal prepared by the Joint Project Team of JAERI and KEK to construct accelerators and research facilities necessary both for the NSP and the JHF at the site of JAERI Tokai Establishment. (author)

  12. A Highly intense DC muon source, MuSIC and muon CLFV search

    International Nuclear Information System (INIS)

    Hino, Y.; Kuno, Y.; Sato, A.; Sakamoto, H.; Matsumoto, Y.; Tran, N.H.; Hashim, I.H.; Fukuda, M.; Hayashida, Y.; Ogitsu, T.; Yamamoto, A.; Yoshida, M.

    2014-01-01

    MuSIC is a new muon facility, which provides the world's highest intense muon beam with continuous time structure at Research Center of Nuclear Physics (RCNP), Osaka University. It's intensity is designed to be 10 8 muons per second with only 0.4 kW proton beam. Such a high intense muon beam is very important for searches of rare decay processes, for example search for the muon to electron conversion

  13. Enhanced radiative Auger emission from lithiumlike 20Ca17+

    International Nuclear Information System (INIS)

    Bernstein, E.M.; Clark, M.W.; Tanis, J.A.; Graham, W.G.; Morgan, T.J.; Stoeckli, M.P.; Berkner, K.H.; Schlachter, A.S.; Stearns, J.W.

    1991-01-01

    Radiative Auger emission (RAE) from lithiumlike 20 Ca 17+ projectiles excited in collisions with He has been measured. The intensity of RAE photons relative to K α X-ray emission is enhanced by a factor of 10-17 compared with theoretical calculations for ions with few electron vacancies. The enhancement of RAE for Ca 17+ is consistent with the results reported previously for lithiumlike 16 S 13+ and 23 V 20+ and indicates a systematic dependence on Z. Both the enhancement and the relative RAE transition rate increase with Z. (orig.)

  14. Ion-microprobe measurements of Mg, Ca, Ti and Fe isotopic ratios and trace element abundance in hibonite-bearing inclusions in primitive meteorites

    International Nuclear Information System (INIS)

    Fahey, A.J.

    1988-01-01

    This thesis reports the isotopic abundances of Mg, Ca, and Ti and rare earth element (REE) abundances in 19 hibonite-bearing inclusions from primative meteorites. The isotopic ratios of Fe were measured in one of the samples, Lance HH-1. These measurements were made by means of secondary ion mass spectrometry (CAMECA IMS-3f). The novel hardware and software developments that made this work possible are described in detail. The samples were studied in thin section in order to investigate the relationship between the inclusions and their mineralogical environments. Inclusions from a number of different meteorites, specifically, Mighei, Murray, Murchison, Lance, Efremovka, Vigarano, Qingzhen, Dhajala, and Semarkona, were studied. The isotopes of Ca and Ti show large and correlated abundance anomalies in their most neutron-rich isotopes, 48 Ca and 50 Ti. The largest anomalies among the samples studied here are in the Murray inclusion MY-F6, with a 4.6% deficit in 48 Ca and a 5.2% deficit in 50 Ti, and Lance HH-1, with 3.3% and 6.0% deficits in 48 Ca and 50 Ti respectively. Correlated excesses of 48 Ca and 50 Ti, up to 2.4% and 1.4% respectively, are found in some other samples studied here. The fact that there is a correlation of isotopic anomalies in two different elements is clear evidence for a nucleosynthetic origin of these effects. Various possibilities for the origin of these isotopic anomalies are discussed and it is shown that a Cosmic Chemical Memory-like model of the incomplete mixing of dust grains from one or several supernovae is sufficient to explain the data. Magnesium isotopes show excesses of 26 Mg, attributable to the in-situ decay of 26 Al, in 7 of these inclusions

  15. Cancer and Exercise: Warburg Hypothesis, Tumour Metabolism and High-Intensity Anaerobic Exercise.

    Science.gov (United States)

    Hofmann, Peter

    2018-01-31

    There is ample evidence that regular moderate to vigorous aerobic physical activity is related to a reduced risk for various forms of cancer to suggest a causal relationship. Exercise is associated with positive changes in fitness, body composition, and physical functioning as well as in patient-reported outcomes such as fatigue, sleep quality, or health-related quality of life. Emerging evidence indicates that exercise may also be directly linked to the control of tumour biology through direct effects on tumour-intrinsic factors. Beside a multitude of effects of exercise on the human body, one underscored effect of exercise training is to target the specific metabolism of tumour cells, namely the Warburg-type highly glycolytic metabolism. Tumour metabolism as well as the tumour⁻host interaction may be selectively influenced by single bouts as well as regularly applied exercise, dependent on exercise intensity, duration, frequency and mode. High-intensity anaerobic exercise was shown to inhibit glycolysis and some studies in animals showed that effects on tumour growth might be stronger compared with moderate-intensity aerobic exercise. High-intensity exercise was shown to be safe in patients; however, it has to be applied carefully with an individualized prescription of exercise.

  16. Effects of high-intensity swimming training on GLUT-4 and glucose transport activity in rat skeletal muscle.

    Science.gov (United States)

    Terada, S; Yokozeki, T; Kawanaka, K; Ogawa, K; Higuchi, M; Ezaki, O; Tabata, I

    2001-06-01

    This study was performed to assess the effects of short-term, extremely high-intensity intermittent exercise training on the GLUT-4 content of rat skeletal muscle. Three- to four-week-old male Sprague-Dawley rats with an initial body weight ranging from 45 to 55 g were used for this study. These rats were randomly assigned to an 8-day period of high-intensity intermittent exercise training (HIT), relatively high-intensity intermittent prolonged exercise training (RHT), or low-intensity prolonged exercise training (LIT). Age-matched sedentary rats were used as a control. In the HIT group, the rats repeated fourteen 20-s swimming bouts with a weight equivalent to 14, 15, and 16% of body weight for the first 2, the next 4, and the last 2 days, respectively. Between exercise bouts, a 10-s pause was allowed. RHT consisted of five 17-min swimming bouts with a 3-min rest between bouts. During the first bout, the rat swam without weight, whereas during the following four bouts, the rat was attached to a weight equivalent to 4 and 5% of its body weight for the first 5 days and the following 3 days, respectively. Rats in the LIT group swam 6 h/day for 8 days in two 3-h bouts separated by 45 min of rest. In the first experiment, the HIT, LIT, and control rats were compared. GLUT-4 content in the epitrochlearis muscle in the HIT and LIT groups after training was significantly higher than that in the control rats by 83 and 91%, respectively. Furthermore, glucose transport activity, stimulated maximally by both insulin (2 mU/ml) (HIT: 48%, LIT: 75%) and contractions (25 10-s tetani) (HIT: 55%, LIT: 69%), was higher in the training groups than in the control rats. However, no significant differences in GLUT-4 content or in maximal glucose transport activity in response to both insulin and contractions were observed between the two training groups. The second experiment demonstrated that GLUT-4 content after HIT did not differ from that after RHT (66% higher in trained rats than

  17. Applications of super - high intensity lasers in nuclear engineering

    International Nuclear Information System (INIS)

    Salomaa, R.; Hakola, A.; Santala, M.

    2007-01-01

    Laser-plasma interactions arising when a super intense ultrashort laser pulse impinges a solid target creates intense partly collimated and energy resolved photons, high energy electron and protons and neutrons. In addition the plasma plume can generate huge magnetic and electric fields. Also ultra short X-ray pulses are created. We have participated in some of such experiments at Rutherford and Max-Planck Institute and assessed the applications of such kind as laser-driven accelerators. This paper discusses applications in nuclear engineering (neutron sources, isotope separation, fast ignition and transmutation, etc). In particular the potential for extreme time resolution and to partial energy resolution are assessed

  18. Ferromagnetic Instability in AFe4Sb12 (A = Ca, Sr, and Ba)

    OpenAIRE

    Matsuoka, E.; Hayashi, K.; Ikeda, A.; Tanaka, K.; Takabatake, T.; Higemoto, W.; Matsumura, M.

    2004-01-01

    Magnetic, transport and thermal properties of AFe4Sb12 (A = Ca, Sr, Ba) are reported. All three compounds show a maximum in both the magnetic susceptibility and thermopower at 50 K, and a large electronic specific heat coefficient of 100 mJ/mol K2. These properties are the characteristics of a nearly ferromagnetic metal. Furthermore, a remanent moment of the order of 10-3muB/Fe was observed below 54, 48, and 40 K for A = Ca, Sr, and Ba, respectively. The volume fraction of the ferromagnetic c...

  19. Age-Related Changes in Associations Between Reasons for Alcohol Use and High-Intensity Drinking Across Young Adulthood.

    Science.gov (United States)

    Patrick, Megan E; Evans-Polce, Rebecca; Kloska, Deborah D; Maggs, Jennifer L; Lanza, Stephanie T

    2017-07-01

    Analyses focus on whether self-reported reasons for drinking alcohol change in their associations with high-intensity drinking across the transition to adulthood. Self-report data on high-intensity drinking (10+ drinks) collected from the national Monitoring the Future study in 2005 to 2014 from those ages 18-26 were used (N = 2,664 [60% women] for all drinkers and 1,377 for heavy episodic [5+] drinkers; up to 6,541 person-waves). Time-varying effect modeling examined changes in the direction and magnitude of associations between eight reasons for drinking and high-intensity alcohol use across continuous age. Four reasons to drink showed quite stable associations with high-intensity drinking across age: drinking to get away from problems, to get high, to relax, and to sleep. Associations between two reasons and high-intensity drinking decreased with age: anger/frustration and to have a good time. The association between drinking because of boredom and high-intensity drinking increased with age. Drinking because it tastes good had a weak association with high-intensity drinking. Among heavy episodic drinkers, reasons for use also differentiated high-intensity drinking, with two exceptions: drinking to have a good time and to relax did not distinguish drinking 10+ drinks from drinking 5-9 drinks. Reasons for drinking are differentially associated with high-intensity drinking, compared with any other drinking and compared with lower intensity heavy drinking, across age during the transition to adulthood. Intervention programs seeking to mitigate alcohol-related harms should focus on reasons for use when they are the most developmentally salient.

  20. PTFE Additive and Re-annealing Effect on Thermoluminescence Response of CaSO4:Dy Derived from Co-precipitation Method

    Science.gov (United States)

    Nuraeni, Nunung; Dwi Septianto, Ricky; Iskandar, Ferry; Haryanto, Freddy; Waris, Abdul; Hiswara, Eri

    2017-07-01

    Effect of re-annealing treatment in thermoluminescence response of thermoluminescent dosimeter (TLD) CaSO4:Dy and CaSO4:Dy with PTFE (Polytetrafluoroethylene) addition was investigated. CaSO4:Dy was prepared by a co-precipitation method. The PTFE was added before re-annealing treatment which the mass ratio of CaSO4:Dy and PTFE was fixed to 2:3. The re-annealing treatments of the samples were done at temperature 700 °C for 1 hr. The obtained samples were characterized using a Fourier-transform infrared (FTIR) and X-ray diffraction (XRD) to observe the molecule bonding in sample and crystal properties, respectively. From the experimental results, it was observed that the thermoluminescence intensity of CaSO4:Dy, CaSO4:Dy re-annealed at 700 °C, and CaSO4:Dy + PTFE re-annealed at 700 °C are 57.03, 75.15, and 1191.11 nC, respectively. The intensity of 700 °C-re-annealed CaSO4:Dy increased significantly after PTFE addition.